Sample records for ultrasound-guided interventional procedures

  1. Efficacy of ultrasound-guided thoracentesis catheter drainage for pleural effusion

    PubMed Central

    Cao, Weitian; Wang, Yi; Zhou, Ningming; Xu, Bing

    2016-01-01

    The factors influencing the efficacy of ultrasound-guided thoracentesis catheter drainage were investigated in the present study. A retrospective analysis of clinical data from 435 patients who presented with a pleural effusion was performed. Patients were divided into a control group and an intervention group. Thirty-seven patients in the control group were given standard care using pleural puncture to draw the excess fluid. The 398 patients in the intervention group were treated using ultrasound-guided thoracentesis catheter drainage. The rate of successful drainage of a pleural effusion was significantly higher (P<0.05), while the rate of complication was lower, in the ultrasound-guided thoracentesis cases compared to standard care treatment. In conclusion, ultrasound-guided thoracentesis catheter drainage is an efficient, safe and minimally invasive procedure to alleviate pleural effusion. The efficacy of the procedure is related to the separation of pleural effusion, drainage tube type and tube diameter. PMID:28105155

  2. The American Society of Regional Anesthesia and Pain Medicine, the European Society of Regional Anaesthesia and Pain Therapy, and the Asian Australasian Federation of Pain Societies Joint Committee recommendations for education and training in ultrasound-guided interventional pain procedures.

    PubMed

    Narouze, Samer N; Provenzano, David; Peng, Philip; Eichenberger, Urs; Lee, Sang Chul; Nicholls, Barry; Moriggl, Bernhard

    2012-01-01

    The use of ultrasound in pain medicine for interventional axial, nonaxial, and musculoskeletal pain procedures is rapidly evolving and growing. Because of the lack of specialty-specific guidelines for ultrasonography in pain medicine, an international collaborative effort consisting of members of the Special Interest Group on Ultrasonography in Pain Medicine from the American Society of Regional Anesthesia and Pain Medicine, the European Society of Regional Anaesthesia and Pain Therapy, and the Asian Australasian Federation of Pain Societies developed the following recommendations for education and training in ultrasound-guided interventional pain procedures. The purpose of these recommendations is to define the required skills for performing ultrasound-guided pain procedures, the processes for appropriate education, and training and quality improvement. Training algorithms are outlined for practice- and fellowship-based pathways. The previously published American Society of Regional Anesthesia and Pain Medicine and European Society of Regional Anaesthesia and Pain Therapy education and teaching recommendations for ultrasound-guided regional anesthesia served as a foundation for the pain medicine recommendations. Although the decision to grant ultrasound privileges occurs at the institutional level, the committee recommends that the training guidelines outlined in this document serve as the foundation for educational training and the advancement of the practice of ultrasonography in pain medicine.

  3. [Contrast-enhanced ultrasound (CEUS) and image fusion for procedures of liver interventions].

    PubMed

    Jung, E M; Clevert, D A

    2018-06-01

    Contrast-enhanced ultrasound (CEUS) is becoming increasingly important for the detection and characterization of malignant liver lesions and allows percutaneous treatment when surgery is not possible. Contrast-enhanced ultrasound image fusion with computed tomography (CT) and magnetic resonance imaging (MRI) opens up further options for the targeted investigation of a modified tumor treatment. Ultrasound image fusion offers the potential for real-time imaging and can be combined with other cross-sectional imaging techniques as well as CEUS. With the implementation of ultrasound contrast agents and image fusion, ultrasound has been improved in the detection and characterization of liver lesions in comparison to other cross-sectional imaging techniques. In addition, this method can also be used for intervention procedures. The success rate of fusion-guided biopsies or CEUS-guided tumor ablation lies between 80 and 100% in the literature. Ultrasound-guided image fusion using CT or MRI data, in combination with CEUS, can facilitate diagnosis and therapy follow-up after liver interventions. In addition to the primary applications of image fusion in the diagnosis and treatment of liver lesions, further useful indications can be integrated into daily work. These include, for example, intraoperative and vascular applications as well applications in other organ systems.

  4. American Medical Society for Sports Medicine (AMSSM) position statement: interventional musculoskeletal ultrasound in sports medicine.

    PubMed

    Finnoff, Jonathan T; Hall, Mederic M; Adams, Erik; Berkoff, David; Concoff, Andrew L; Dexter, William; Smith, Jay

    2015-02-01

    The use of diagnostic and interventional ultrasound has significantly increased over the past decade. A majority of the increased utilisation is by non-radiologists. In sports medicine, ultrasound is often used to guide interventions such as aspirations, diagnostic or therapeutic injections, tenotomies, releases and hydrodissections. Critically review the literature related to the accuracy, efficacy and cost-effectiveness of ultrasound-guided injections (USGIs) in major, intermediate and small joints; and soft tissues. Systematic review of the literature. USGIs are more accurate than landmark-guided injections (LMGIs; strength of recommendation taxonomy (SORT) Evidence Rating=A). USGIs are more efficacious than LMGIs (SORT Evidence Rating=B). USGIs are more cost-effective than LMGIs (SORT Evidence Rating=B). Ultrasound guidance is required to perform many new procedures (SORT Evidence Rating=C). The findings of this position statement indicate there is strong evidence that USGIs are more accurate than LMGI, moderate evidence that they are more efficacious and preliminary evidence that they are more cost-effective. Furthermore, ultrasound-guided (USG) is required to perform many new, advanced procedures and will likely enable the development of innovative USG surgical techniques in the future. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  5. Line fiducial material and thickness considerations for ultrasound calibration

    NASA Astrophysics Data System (ADS)

    Ameri, Golafsoun; McLeod, A. J.; Baxter, John S. H.; Chen, Elvis C. S.; Peters, Terry M.

    2015-03-01

    Ultrasound calibration is a necessary procedure in many image-guided interventions, relating the position of tools and anatomical structures in the ultrasound image to a common coordinate system. This is a necessary component of augmented reality environments in image-guided interventions as it allows for a 3D visualization where other surgical tools outside the imaging plane can be found. Accuracy of ultrasound calibration fundamentally affects the total accuracy of this interventional guidance system. Many ultrasound calibration procedures have been proposed based on a variety of phantom materials and geometries. These differences lead to differences in representation of the phantom on the ultrasound image which subsequently affect the ability to accurately and automatically segment the phantom. For example, taut wires are commonly used as line fiducials in ultrasound calibration. However, at large depths or oblique angles, the fiducials appear blurred and smeared in ultrasound images making it hard to localize their cross-section with the ultrasound image plane. Intuitively, larger diameter phantoms with lower echogenicity are more accurately segmented in ultrasound images in comparison to highly reflective thin phantoms. In this work, an evaluation of a variety of calibration phantoms with different geometrical and material properties for the phantomless calibration procedure was performed. The phantoms used in this study include braided wire, plastic straws, and polyvinyl alcohol cryogel tubes with different diameters. Conventional B-mode and synthetic aperture images of the phantoms at different positions were obtained. The phantoms were automatically segmented from the ultrasound images using an ellipse fitting algorithm, the centroid of which is subsequently used as a fiducial for calibration. Calibration accuracy was evaluated for these procedures based on the leave-one-out target registration error. It was shown that larger diameter phantoms with lower echogenicity are more accurately segmented in comparison to highly reflective thin phantoms. This improvement in segmentation accuracy leads to a lower fiducial localization error, which ultimately results in low target registration error. This would have a profound effect on calibration procedures and the feasibility of different calibration procedures in the context of image-guided procedures.

  6. Magnetic navigation in ultrasound-guided interventional radiology procedures.

    PubMed

    Xu, H-X; Lu, M-D; Liu, L-N; Guo, L-H

    2012-05-01

    To evaluate the usefulness of magnetic navigation in ultrasound (US)-guided interventional procedures. Thirty-seven patients who were scheduled for US-guided interventional procedures (20 liver cancer ablation procedures and 17 other procedures) were included. Magnetic navigation with three-dimensional (3D) computed tomography (CT), magnetic resonance imaging (MRI), 3D US, and position-marking magnetic navigation were used for guidance. The influence on clinical outcome was also evaluated. Magnetic navigation facilitated applicator placement in 15 of 20 ablation procedures for liver cancer in which multiple ablations were performed; enhanced guidance in two small liver cancers invisible on conventional US but visible at CT or MRI; and depicted the residual viable tumour after transcatheter arterial chemoembolization for liver cancer in one procedure. In four of 17 other interventional procedures, position-marking magnetic navigation increased the visualization of the needle tip. Magnetic navigation was beneficial in 11 (55%) of 20 ablation procedures; increased confidence but did not change management in five (25%); added some information but did not change management in two (10%); and made no change in two (10%). In the other 17 interventional procedures, the corresponding numbers were 1 (5.9%), 2 (11.7%), 7 (41.2%), and 7 (41.2%), respectively (p=0.002). Magnetic navigation in US-guided interventional procedure provides solutions in some difficult cases in which conventional US guidance is not suitable. It is especially useful in complicated interventional procedures such as ablation for liver cancer. Copyright © 2011 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  7. An interventional multispectral photoacoustic imaging platform for the guidance of minimally invasive procedures

    NASA Astrophysics Data System (ADS)

    Xia, Wenfeng; Nikitichev, Daniil I.; Mari, Jean Martial; West, Simeon J.; Ourselin, Sebastien; Beard, Paul C.; Desjardins, Adrien E.

    2015-07-01

    Precise and efficient guidance of medical devices is of paramount importance for many minimally invasive procedures. These procedures include fetal interventions, tumor biopsies and treatments, central venous catheterisations and peripheral nerve blocks. Ultrasound imaging is commonly used for guidance, but it often provides insufficient contrast with which to identify soft tissue structures such as vessels, tumors, and nerves. In this study, a hybrid interventional imaging system that combines ultrasound imaging and multispectral photoacoustic imaging for guiding minimally invasive procedures was developed and characterized. The system provides both structural information from ultrasound imaging and molecular information from multispectral photoacoustic imaging. It uses a commercial linear-array ultrasound imaging probe as the ultrasound receiver, with a multimode optical fiber embedded in a needle to deliver pulsed excitation light to tissue. Co-registration of ultrasound and photoacoustic images is achieved with the use of the same ultrasound receiver for both modalities. Using tissue ex vivo, the system successfully discriminated deep-located fat tissue from the surrounding muscle tissue. The measured photoacoustic spectrum of the fat tissue had good agreement with the lipid spectrum in literature.

  8. Endoscopic ultrasound-guided biliary drainage

    PubMed Central

    Chavalitdhamrong, Disaya; Draganov, Peter V

    2012-01-01

    Endoscopic ultrasound (EUS)-guided biliary drainage has emerged as a minimally invasive alternative to percutaneous and surgical interventions for patients with biliary obstruction who had failed endoscopic retrograde cholangiopancreatography (ERCP). EUS-guided biliary drainage has become feasible due to the development of large channel curvilinear therapeutic echo-endoscopes and the use of real-time ultrasound and fluoroscopy imaging in addition to standard ERCP devices and techniques. EUS-guided biliary drainage is an attractive option because of its minimally invasive, single step procedure which provides internal biliary decompression. Multiple investigators have reported high success and low complication rates. Unfortunately, high quality prospective data are still lacking. We provide detailed review of the use of EUS for biliary drainage from the perspective of practicing endoscopists with specific focus on the technical aspects of the procedure. PMID:22363114

  9. Ultrasound-guided Interventions for Core and Hip Injuries in Athletes.

    PubMed

    McCarthy, Eoghan; Hegazi, Tarek M; Zoga, Adam C; Morrison, William B; Meyers, William C; Poor, Alex E; Nevalainen, Mika T; Roedl, Johannes B

    2016-09-01

    Trauma and the mechanical strain of high-energy activity predispose athletes to pelvic injuries. Magnetic resonance imaging remains the primary modality for diagnosing these conditions, but ultrasonography-guided interventions are important in the management of core muscle, hip, and other pelvic conditions. This article reviews ultrasonography-guided interventions for injuries at the core, including the pelvis and hips. It reviews common injuries, procedure optimization, medication preparation, clinical evidence behind injections, tenotomy, and platelet-rich plasma. These interventions are especially important in athletes, because ultrasonography-guided procedures are often undertaken early in the treatment process, paralleling conservative rehabilitation to facilitate a faster return to play. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. A Randomized Controlled Trial Evaluating the See, Tilt, Align, and Rotate (STAR) Maneuver on Skill Acquisition for Simulated Ultrasound-Guided Interventional Procedures.

    PubMed

    Lam, Nicholas C K; Fishburn, Steven J; Hammer, Angie R; Petersen, Timothy R; Gerstein, Neal S; Mariano, Edward R

    2015-06-01

    Achieving the best view of the needle and target anatomy when performing ultrasound-guided interventional procedures requires technical skill, which novices may find difficult to learn. We hypothesized that teaching novice performers to use 4 sequential steps (see, tilt, align, and rotate [STAR] method) to identify the needle under ultrasound guidance is more efficient than training with the commonly described probe movements of align, rotate, and tilt (ART). This study compared 2 instructional methods for transducer manipulation including alignment of a probe and needle by novices during a simulated ultrasound-guided nerve block. Right-handed volunteers between the ages of 18 and 55 years who had no previous ultrasound experience were recruited and randomized to 1 of 2 groups; one group was trained to troubleshoot misalignment with the ART method, and the other was trained with the new STAR maneuver. Participants performed the task, consisting of directing a needle in plane to 3 targets in a standardized gelatin phantom 3 times. The performance assessor and data analyst were blinded to group assignment. Thirty-five participants were recruited. The STAR group was able to complete the task more quickly (P < .001) and visualized the needle in a greater proportion of the procedure time (P = .004) compared to the ART group. All STAR participants were able to complete the task, whereas 41% of ART participants abandoned the task (P = .003). Novices are able to complete a simulated ultrasound-guided nerve block more quickly and efficiently when trained with the 4-step STAR maneuver compared to the ART method. © 2015 by the American Institute of Ultrasound in Medicine.

  11. Complications and adequacy of transplant kidney biopsies: A comparison of techniques.

    PubMed

    Plattner, Brett W; Chen, Pauline; Cross, Richard; Leavitt, Matthew A; Killen, Paul D; Heung, Michael

    2018-05-01

    Kidney biopsies are an essential tool in the diagnosis and management of kidney diseases, particularly in kidney transplant recipients. Biopsies carry a risk for serious complications and not all biopsies achieve adequate tissue. We examined the impact of kidney biopsy technique on complications and biopsy adequacy. The cohort consisted of consecutive kidney transplant patients undergoing biopsy by one of three techniques: ultrasound localization, real-time ultrasound guidance, and ultrasound-guided trocar placement. Variables of interest included patient characteristics and procedural characteristics. The primary outcome was serious complication attributable to kidney biopsy, and the secondary outcome was biopsy adequacy as defined by Banff criteria. Among 263 patients undergoing biopsy, 27 (10.3%) had a complication (14 with gross hematuria, 10 requiring blood transfusion, 3 requiring an unplanned interventional radiology procedure, 1 kidney loss; no deaths). Complications were more common among patients biopsied using ultrasound-guided trocar compared to real-time ultrasound and ultrasound localization (21.4% vs 7.9% vs 7.1%, respectively, p = 0.008). After adjusting for patient and procedure characteristics, technique was no longer significantly associated with complication. Biopsy adequacy was significantly higher when using ultrasound localization and real-time ultrasound compared to ultrasound-guided trocar (84.6% vs 86.8% vs 69.6%, p = 0.029), and this finding persisted in adjusted analysis. Kidney biopsy complications appear to be similar when using any of the three techniques examined in our study. However, ultrasound-guided trocar technique may yield lower biopsy adequacy when compared to non-trocar techniques.

  12. Image-guided interventional procedures in the dog and cat.

    PubMed

    Vignoli, Massimo; Saunders, Jimmy H

    2011-03-01

    Medical imaging is essential for the diagnostic workup of many soft tissue and bone lesions in dogs and cats, but imaging modalities do not always allow the clinician to differentiate inflammatory or infectious conditions from neoplastic disorders. This review describes interventional procedures in dogs and cats for collection of samples for cytological or histopathological examinations under imaging guidance. It describes the indications and procedures for imaging-guided sampling, including ultrasound (US), computed tomography (CT), magnetic resonance imaging and fluoroscopy. US and CT are currently the modalities of choice in interventional imaging. Copyright © 2009 Elsevier Ltd. All rights reserved.

  13. Ultrasound-guided peripheral nerve interventions for common pain disorders

    PubMed Central

    Krishna Prasad, B P; Joy, Binu; Raghavendra, Vijayakumar A; Toms, Ajith; George, Danny; Ray, Brijesh

    2018-01-01

    There are a number of common pain disorders that can be managed effectively by injections around or ablation of peripheral nerves. Ultrasound is a universally available imaging tool, is safe, cost-effective, and is excellent in imaging many peripheral nerves and guiding needles to the site of the nerves. This article aims to present an overview of indications and techniques of such procedures that can be effectively performed by a radiologist. PMID:29692534

  14. Ultrasound in Radiology: from Anatomic, Functional, Molecular Imaging to Drug Delivery and Image-Guided Therapy

    PubMed Central

    Klibanov, Alexander L.; Hossack, John A.

    2015-01-01

    During the past decade, ultrasound has expanded medical imaging well beyond the “traditional” radiology setting - a combination of portability, low cost and ease of use makes ultrasound imaging an indispensable tool for radiologists as well as for other medical professionals who need to obtain imaging diagnosis or guide a therapeutic intervention quickly and efficiently. Ultrasound combines excellent ability for deep penetration into soft tissues with very good spatial resolution, with only a few exceptions (i.e. those involving overlying bone or gas). Real-time imaging (up to hundreds and thousands frames per second) enables guidance of therapeutic procedures and biopsies; characterization of the mechanical properties of the tissues greatly aids with the accuracy of the procedures. The ability of ultrasound to deposit energy locally brings about the potential for localized intervention encompassing: tissue ablation, enhancing penetration through the natural barriers to drug delivery in the body and triggering drug release from carrier micro- and nanoparticles. The use of microbubble contrast agents brings the ability to monitor and quantify tissue perfusion, and microbubble targeting with ligand-decorated microbubbles brings the ability to obtain molecular biomarker information, i.e., ultrasound molecular imaging. Overall, ultrasound has become the most widely used imaging modality in modern medicine; it will continue to grow and expand. PMID:26200224

  15. Ultrasound-Guided Cryoanalgesia of Peripheral Nerve Lesions.

    PubMed

    Djebbar, Sahlya; Rossi, Ignacio M; Adler, Ronald S

    2016-11-01

    The real-time nature of ultrasound makes it ideally suited to provide guidance for a variety of musculoskeletal interventional procedures involving peripheral nerves. Continuous observation of the needle ensures proper placement and allows continuous monitoring when performing localized ablative therapy and therefore more accurate positioning of a cryoprobe, use of smaller needles, as well as access to small structures. We describe our experience performing cryoablative procedures. Patients undergoing cryoneurolysis have largely reported varying degrees of long-term pain relief and improvement in function; no serious complications have yet been identified. Ultrasound-guided cryoneurolysis can provide a useful, safe alternative to other ablative techniques to achieve long-term analgesia from painful peripheral nerve lesions. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  16. Navigational ultrasound imaging: A novel imaging tool for aiding interventional therapies of equine musculoskeletal injuries.

    PubMed

    Lustgarten, M; Redding, W R; Schnabel, L V; Prange, T; Seiler, G S

    2016-03-01

    Navigational ultrasound imaging, also known as fusion imaging, is a novel technology that allows real-time ultrasound imaging to be correlated with a previously acquired computed tomography (CT) or magnetic resonance imaging (MRI) study. It has been used in man to aid interventional therapies and has been shown to be valuable for sampling and assessing lesions diagnosed with MRI or CT that are equivocal on ultrasonography. To date, there are no reports of the use of this modality in veterinary medicine. To assess whether navigational ultrasound imaging can be used to assist commonly performed interventional therapies for the treatment of equine musculoskeletal injuries diagnosed with MRI and determine the appropriateness of regional anatomical landmarks as registration sites. Retrospective, descriptive clinical study. Horses with musculoskeletal injuries of the distal limb diagnosed with MRI scheduled for ultrasound-guided interventional therapies were evaluated (n = 17 horses with a total of 29 lesions). Anatomical landmarks used for image registration for the navigational procedure were documented. Accuracy of lesion location and success of the procedure were assessed subjectively and described using a grading scale. All procedures were accurately registered using regional anatomical landmarks and considered successful based on our criteria. Anatomical landmarks were described for each lesion type. The addition of navigational imaging was considered to greatly aid the procedures in 59% of cases and added information to the remainder of the procedures. The technique was considered to improve the precision of these interventional procedures. Navigational ultrasound imaging is a complementary imaging modality that can be used for the treatment of equine soft tissue musculoskeletal injuries diagnosed with MRI. © 2015 EVJ Ltd.

  17. Ultrasound image guidance of cardiac interventions

    NASA Astrophysics Data System (ADS)

    Peters, Terry M.; Pace, Danielle F.; Lang, Pencilla; Guiraudon, Gérard M.; Jones, Douglas L.; Linte, Cristian A.

    2011-03-01

    Surgical procedures often have the unfortunate side-effect of causing the patient significant trauma while accessing the target site. Indeed, in some cases the trauma inflicted on the patient during access to the target greatly exceeds that caused by performing the therapy. Heart disease has traditionally been treated surgically using open chest techniques with the patient being placed "on pump" - i.e. their circulation being maintained by a cardio-pulmonary bypass or "heart-lung" machine. Recently, techniques have been developed for performing minimally invasive interventions on the heart, obviating the formerly invasive procedures. These new approaches rely on pre-operative images, combined with real-time images acquired during the procedure. Our approach is to register intra-operative images to the patient, and use a navigation system that combines intra-operative ultrasound with virtual models of instrumentation that has been introduced into the chamber through the heart wall. This paper illustrates the problems associated with traditional ultrasound guidance, and reviews the state of the art in real-time 3D cardiac ultrasound technology. In addition, it discusses the implementation of an image-guided intervention platform that integrates real-time ultrasound with a virtual reality environment, bringing together the pre-operative anatomy derived from MRI or CT, representations of tracked instrumentation inside the heart chamber, and the intra-operatively acquired ultrasound images.

  18. Guided Interventions for Prostate Cancer Using 3D-Transurethral Ultrasound and MRI Fusion

    DTIC Science & Technology

    2015-10-01

    AWARD NUMBER: W81XWH-14-1-0461 TITLE: Guided Interventions for Prostate Cancer Using 3D-Transurethral Ultrasound and MRI Fusion PRINCIPAL...Sep 2014 - 28 Sep 2015 4. TITLE AND SUBTITLE 5a. CONTRACT NUMBER Guided Interventions for Prostate Cancer Using 3D- Transurethral Ultrasound and...Magnetic Resonance- Ultrasound (MR-US) fusion allows for specific targeting of the tumors in real-time during clinical interventions, outside of an MR

  19. MRI-guided and CT-guided cervical nerve root infiltration therapy: a cost comparison.

    PubMed

    Maurer, M H; Froeling, V; Röttgen, R; Bretschneider, T; Hartwig, T; Disch, A C; de Bucourt, M; Hamm, B; Streitparth, F

    2014-06-01

    To evaluate and compare the costs of MRI-guided and CT-guided cervical nerve root infiltration for the minimally invasive treatment of radicular neck pain. Between September 2009 and April 2012, 22 patients (9 men, 13 women; mean age: 48.2 years) underwent MRI-guided (1.0 Tesla, Panorama HFO, Philips) single-site periradicular cervical nerve root infiltration with 40 mg triamcinolone acetonide. A further 64 patients (34 men, 30 women; mean age: 50.3 years) were treated under CT fluoroscopic guidance (Somatom Definition 64, Siemens). The mean overall costs were calculated as the sum of the prorated costs of equipment use (purchase, depreciation, maintenance, and energy costs), personnel costs and expenditure for disposables that were identified for MRI- and CT-guided procedures. Additionally, the cost of ultrasound guidance was calculated. The mean intervention time was 24.9 min. (range: 12 - 36 min.) for MRI-guided infiltration and 19.7 min. (range: 5 - 54 min.) for CT-guided infiltration. The average total costs per patient were EUR 240 for MRI-guided interventions and EUR 124 for CT-guided interventions. These were (MRI/CT guidance) EUR 150/60 for equipment use, EUR 46/40 for personnel, and EUR 44/25 for disposables. The mean overall cost of ultrasound guidance was EUR 76. Cervical nerve root infiltration using MRI guidance is still about twice as expensive as infiltration using CT guidance. However, since it does not involve radiation exposure for patients and personnel, MRI-guided nerve root infiltration may become a promising alternative to the CT-guided procedure, especially since a further price decrease is expected for MRI devices and MR-compatible disposables. In contrast, ultrasound remains the less expensive method for nerve root infiltration guidance. © Georg Thieme Verlag KG Stuttgart · New York.

  20. Interventional multispectral photoacoustic imaging with a clinical linear array ultrasound probe for guiding nerve blocks

    NASA Astrophysics Data System (ADS)

    Xia, Wenfeng; West, Simeon J.; Nikitichev, Daniil I.; Ourselin, Sebastien; Beard, Paul C.; Desjardins, Adrien E.

    2016-03-01

    Accurate identification of tissue structures such as nerves and blood vessels is critically important for interventional procedures such as nerve blocks. Ultrasound imaging is widely used as a guidance modality to visualize anatomical structures in real-time. However, identification of nerves and small blood vessels can be very challenging, and accidental intra-neural or intra-vascular injections can result in significant complications. Multi-spectral photoacoustic imaging can provide high sensitivity and specificity for discriminating hemoglobin- and lipid-rich tissues. However, conventional surface-illumination-based photoacoustic systems suffer from limited sensitivity at large depths. In this study, for the first time, an interventional multispectral photoacoustic imaging (IMPA) system was used to image nerves in a swine model in vivo. Pulsed excitation light with wavelengths in the ranges of 750 - 900 nm and 1150 - 1300 nm was delivered inside the body through an optical fiber positioned within the cannula of an injection needle. Ultrasound waves were received at the tissue surface using a clinical linear array imaging probe. Co-registered B-mode ultrasound images were acquired using the same imaging probe. Nerve identification was performed using a combination of B-mode ultrasound imaging and electrical stimulation. Using a linear model, spectral-unmixing of the photoacoustic data was performed to provide image contrast for oxygenated and de-oxygenated hemoglobin, water and lipids. Good correspondence between a known nerve location and a lipid-rich region in the photoacoustic images was observed. The results indicate that IMPA is a promising modality for guiding nerve blocks and other interventional procedures. Challenges involved with clinical translation are discussed.

  1. Interventional articular and para-articular knee procedures

    PubMed Central

    Lalam, Radhesh K; Winn, Naomi

    2016-01-01

    The knee is a common area of the body to undergo interventional procedures. This article discusses image-guided interventional issues specific to the knee area. The soft tissues in and around the knee are frequently affected by sport-related injuries and often need image-guided intervention. This article details the specific technical issues related to intervention in these soft tissues, including the iliotibial tract, fat pads, patellar tendon and other tendons, bursae and the meniscus. Most often, simple procedures such as injection and aspiration are performed without image guidance. Rarely image-guided diagnostic arthrography and therapeutic joint injections are necessary. The technique, indications and diagnostic considerations for arthrography are discussed in this article. Primary bone and soft-tissue tumours may involve the knee and adjacent soft tissues. Image-guided biopsies are frequently necessary for these lesions; this article details the technical issues related to image-guided biopsy around the knee. A number of newer ablation treatments are now available, including cryoablation, high-frequency ultrasound and microwave ablation. Radiofrequency ablation, however, still remains the most commonly employed ablation technique. The indications, technical and therapeutic considerations related to the application of this technique around the knee are discussed here. Finally, we briefly discuss some newer, but as of yet, unproven image-guided interventions for osteochondral lesions and Brodie's abscess. PMID:26682669

  2. PLUS: open-source toolkit for ultrasound-guided intervention systems.

    PubMed

    Lasso, Andras; Heffter, Tamas; Rankin, Adam; Pinter, Csaba; Ungi, Tamas; Fichtinger, Gabor

    2014-10-01

    A variety of advanced image analysis methods have been under the development for ultrasound-guided interventions. Unfortunately, the transition from an image analysis algorithm to clinical feasibility trials as part of an intervention system requires integration of many components, such as imaging and tracking devices, data processing algorithms, and visualization software. The objective of our paper is to provide a freely available open-source software platform-PLUS: Public software Library for Ultrasound-to facilitate rapid prototyping of ultrasound-guided intervention systems for translational clinical research. PLUS provides a variety of methods for interventional tool pose and ultrasound image acquisition from a wide range of tracking and imaging devices, spatial and temporal calibration, volume reconstruction, simulated image generation, and recording and live streaming of the acquired data. This paper introduces PLUS, explains its functionality and architecture, and presents typical uses and performance in ultrasound-guided intervention systems. PLUS fulfills the essential requirements for the development of ultrasound-guided intervention systems and it aspires to become a widely used translational research prototyping platform. PLUS is freely available as open source software under BSD license and can be downloaded from http://www.plustoolkit.org.

  3. Performance characteristics of an interventional multispectral photoacoustic imaging system for guiding minimally invasive procedures

    PubMed Central

    Mari, Jean Martial; West, Simeon J.; Pratt, Rosalind; David, Anna L.; Ourselin, Sebastien; Beard, Paul C.; Desjardins, Adrien E.

    2016-01-01

    Precise device guidance is important for interventional procedures in many different clinical fields including fetal medicine, regional anesthesia, interventional pain management, and interventional oncology. While ultrasound is widely used in clinical practice for real-time guidance, the image contrast that it provides can be insufficient for visualizing tissue structures such as blood vessels, nerves, and tumors. This study was centered on the development of a photoacoustic imaging system for interventional procedures that delivered excitation light in the ranges of 750 to 900 nm and 1150 to 1300 nm, with an optical fiber positioned in a needle cannula. Coregistered B-mode ultrasound images were obtained. The system, which was based on a commercial ultrasound imaging scanner, has an axial resolution in the vicinity of 100 μm and a submillimeter, depth-dependent lateral resolution. Using a tissue phantom and 800 nm excitation light, a simulated blood vessel could be visualized at a maximum distance of 15 mm from the needle tip. Spectroscopic contrast for hemoglobin and lipids was observed with ex vivo tissue samples, with photoacoustic signal maxima consistent with the respective optical absorption spectra. The potential for further optimization of the system is discussed. PMID:26263417

  4. A serious game for learning ultrasound-guided needle placement skills.

    PubMed

    Chan, Wing-Yin; Qin, Jing; Chui, Yim-Pan; Heng, Pheng-Ann

    2012-11-01

    Ultrasound-guided needle placement is a key step in a lot of radiological intervention procedures such as biopsy, local anesthesia and fluid drainage. To help training future intervention radiologists, we develop a serious game to teach the skills involved. We introduce novel techniques for realistic simulation and integrate game elements for active and effective learning. This game is designed in the context of needle placement training based on the some essential characteristics of serious games. Training scenarios are interactively generated via a block-based construction scheme. A novel example-based texture synthesis technique is proposed to simulate corresponding ultrasound images. Game levels are defined based on the difficulties of the generated scenarios. Interactive recommendation of desirable insertion paths is provided during the training as an adaptation mechanism. We also develop a fast physics-based approach to reproduce the shadowing effect of needles in ultrasound images. Game elements such as time-attack tasks, hints and performance evaluation tools are also integrated in our system. Extensive experiments are performed to validate its feasibility for training.

  5. Diagnostic and interventional musculoskeletal ultrasound: part 2. Clinical applications.

    PubMed

    Smith, Jay; Finnoff, Jonathan T

    2009-02-01

    Musculoskeletal ultrasound involves the use of high-frequency sound waves to image soft tissues and bony structures in the body for the purposes of diagnosing pathology or guiding real-time interventional procedures. Recently, an increasing number of physicians have integrated musculoskeletal ultrasound into their practices to facilitate patient care. Technological advancements, improved portability, and reduced costs continue to drive the proliferation of ultrasound in clinical medicine. This increased interest creates a need for education pertaining to all aspects of musculoskeletal ultrasound. The primary purpose of this article is to review diagnostic ultrasound technology and its potential clinical applications in the evaluation and treatment of patients with neurological and musculoskeletal disorders. After reviewing this article, physicians should be able to (1) list the advantages and disadvantages of ultrasound compared to other available imaging modalities; (2) describe how ultrasound machines produce images using sound waves; (3) discuss the steps necessary to acquire and optimize an ultrasound image; (4) understand the difference ultrasound appearances of tendons, nerves, muscles, ligaments, blood vessels, and bones; and (5) identify multiple applications for diagnostic and interventional musculoskeletal ultrasound. Part 2 of this 2-part article will focus on the clinical applications of musculoskeletal ultrasound in clinical practice, including the ultrasonographic appearance of normal and abnormal tissues as well as specific diagnostic and interventional applications in major body regions.

  6. Forward-viewing endoscopic ultrasound-guided NOTES interventions: A study on peritoneoscopic potential

    PubMed Central

    Jeong, Seung Uk; Aizan, Hassanuddin; Song, Tae Jun; Seo, Dong Wan; Kim, Su-Hui; Park, Do Hyun; Lee, Sang Soo; Lee, Sung Koo; Kim, Myung-Hwan

    2013-01-01

    AIM: To evaluate the feasibility of diagnostic and therapeutic transgastric (TG) peritoneoscopic interventions with a forward-viewing endoscopic ultrasound (FV-EUS). METHODS: This prospective endoscopic experimental study used an animal model. Combined TG peritoneoscopic interventions and EUS examination of the intra-abdominal organs were performed using an FV-EUS on 10 animal models (1 porcine and 9 canine). The procedures carried out include EUS evaluation and endoscopic biopsy of intraperitoneal organs, EUS-guided fine needle aspiration (EUS-FNA), EUS-guided radiofrequency ablation (EUS-RFA), and argon plasma coagulation (APC) for hemostatic control. The animals were kept alive for 7 d, and then necropsy was performed to evaluate results and complications. RESULTS: In all 10 animals, TG peritoneoscopy, followed by endoscopic biopsy for the liver, spleen, abdominal wall, and omentum, was performed successfully. APC helped control minor bleeding. Visualization of intra-abdominal solid organs with real-time EUS was accomplished with ease. Intraperitoneal EUS-FNA was successfully performed on the liver, spleen, and kidney. Similarly, a successful outcome was achieved with EUS-RFA of the hepatic parenchyma. No adverse events were recorded during the study. CONCLUSION: Peritoneoscopic natural orifice transluminal endoscopic surgery (NOTES) interventions through FV-EUS were feasible in providing evaluation and performing endoscopic procedures. It promises potential as a platform for future EUS-based NOTES. PMID:24222961

  7. Ultrasound Imaging and Guided Injection for the Lateral and Posterior Hip.

    PubMed

    Chang, Ke-Vin; Wu, Wei-Ting; Lew, Henry L; Özçakar, Levent

    2018-04-01

    Ultrasound has emerged as one of the most utilized tools to diagnose musculoskeletal disorders and to assist in interventions. Traditionally, sonographic examination of the hip joint has been challenging because most of the major structures are deeply situated, thus requiring the use of curvilinear transducer for better penetrance. The posterior lateral hip is a frequent area for musculoskeletal pain and nerve entrapments. Common disorders include greater trochanteric pain syndrome, gluteus medius tendinopathy, piriformis syndrome, pudendal neuralgia, and proximal hamstring tendinopathy. The present review article aims to delineate sonoanatomy of the posterior lateral hip and to exemplify several common ultrasound guided procedures at the greater trochanteric, gluteal, and ischial tuberosity regions.

  8. Diagnostic and interventional musculoskeletal ultrasound: part 1. Fundamentals.

    PubMed

    Smith, Jay; Finnoff, Jonathan T

    2009-01-01

    Musculoskeletal ultrasound involves the use of high-frequency sound waves to image soft tissues and bony structures in the body for the purposes of diagnosing pathology or guiding real-time interventional procedures. Recently, an increasing number of physicians have integrated musculoskeletal ultrasound into their practices to facilitate patient care. Technological advancements, improved portability, and reduced costs continue to drive the proliferation of ultrasound in clinical medicine. This increased interest creates a need for education pertaining to all aspects of musculoskeletal ultrasound. The primary purpose of this article is to review diagnostic ultrasound technology and its potential clinical applications in the evaluation and treatment of patients with neurologic and musculoskeletal disorders. After reviewing this article, physicians should be able to (1) list the advantages and disadvantages of ultrasound compared with other available imaging modalities, (2) describe how ultrasound machines produce images using sound waves, (3) discuss the steps necessary to acquire and optimize an ultrasound image, (4) understand the different ultrasound appearances of tendons, nerves, muscles, ligaments, blood vessels, and bones, and (5) identify multiple applications for diagnostic and interventional musculoskeletal ultrasound in musculoskeletal practice. Part 1 of this 2-part article reviews the fundamentals of clinical ultrasonographic imaging, including relevant physics, equipment, training, image optimization, and scanning principles for diagnostic and interventional purposes.

  9. Ultrasound-guided interventional procedures around the shoulder.

    PubMed

    Messina, Carmelo; Banfi, Giuseppe; Orlandi, Davide; Lacelli, Francesca; Serafini, Giovanni; Mauri, Giovanni; Secchi, Francesco; Silvestri, Enzo; Sconfienza, Luca Maria

    2016-01-01

    Ultrasound is an established modality for shoulder evaluation, being accurate, low cost and radiation free. Different pathological conditions can be diagnosed using ultrasound and can be treated using ultrasound guidance, such as degenerative, traumatic or inflammatory diseases. Subacromial-subdeltoid bursitis is the most common finding on ultrasound evaluation for painful shoulder. Therapeutic injections of corticosteroids are helpful to reduce inflammation and pain. Calcific tendinopathy of rotator cuff affects up to 20% of painful shoulders. Ultrasound-guided treatment may be performed with both single- and double-needle approach. Calcific enthesopathy, a peculiar form of degenerative tendinopathy, is a common and mostly asymptomatic ultrasound finding; dry needling has been proposed in symptomatic patients. An alternative is represented by autologous platelet-rich plasma injections. Intra-articular injections of the shoulder can be performed in the treatment of a variety of inflammatory and degenerative diseases with corticosteroids or hyaluronic acid respectively. Steroid injections around the long head of the biceps brachii tendon are indicated in patients with biceps tendinopathy, reducing pain and humeral tenderness. The most common indication for acromion-clavicular joint injection is degenerative osteoarthritis, with ultrasound representing a useful tool in localizing the joint space and properly injecting various types of drugs (steroids, lidocaine or hyaluronic acid). Suprascapular nerve block is an approved treatment for chronic shoulder pain non-responsive to conventional treatments as well as candidate patients for shoulder arthroscopy. This review provides an overview of these different ultrasonography-guided procedures that can be performed around the shoulder.

  10. Use of the cumulative sum method (CUSUM) to assess the learning curves of ultrasound-guided continuous femoral nerve block.

    PubMed

    Kollmann-Camaiora, A; Brogly, N; Alsina, E; Gilsanz, F

    2017-10-01

    Although ultrasound is a basic competence for anaesthesia residents (AR) there is few data available on the learning process. This prospective observational study aims to assess the learning process of ultrasound-guided continuous femoral nerve block and to determine the number of procedures that a resident would need to perform in order to reach proficiency using the cumulative sum (CUSUM) method. We recruited 19 AR without previous experience. Learning curves were constructed using the CUSUM method for ultrasound-guided continuous femoral nerve block considering 2 success criteria: a decrease of pain score>2 in a [0-10] scale after 15minutes, and time required to perform it. We analyse data from 17 AR for a total of 237 ultrasound-guided continuous femoral nerve blocks. 8/17 AR became proficient for pain relief, however all the AR who did more than 12 blocks (8/8) became proficient. As for time of performance 5/17 of AR achieved the objective of 12minutes, however all the AR who did more than 20 blocks (4/4) achieved it. The number of procedures needed to achieve proficiency seems to be 12, however it takes more procedures to reduce performance time. The CUSUM methodology could be useful in training programs to allow early interventions in case of repeated failures, and develop competence-based curriculum. Copyright © 2017 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  11. Ultrasound-guided interventional therapy for recurrent ovarian chocolate cysts.

    PubMed

    Wang, Lu-Lu; Dong, Xiao-Qiu; Shao, Xiao-Hui; Wang, Si-Ming

    2011-10-01

    The aim of this study was to determine the effectiveness of ultrasound-guided interventional therapy in the treatment of postoperative recurrent chocolate cysts. The 198 patients enrolled in this study were divided into three groups. In group 1, the saline washing group, the cavity of the cyst was washed thoroughly with warm saline. In group 2, the ethanol short-time retention group, after washing with saline, the cyst was injected with 95% ethanol with a volume of half of the fluid aspirated from the cyst. Ten minutes later, the rest of the ethanol was aspirated. In group 3, the ethanol retention group, the procedures were the same as with the ethanol short-time retention group, except that 95% of the ethanol was retained in the cyst. An ultrasound examination was performed in the third, sixth and 12th months after therapy. The chocolate cyst cure rate was significantly higher in the ethanol retention group (96%, 66/69) than in the ethanol short-time retention group (82%, 56/68) and no case was cured in the first group (saline washing). We conclude that ultrasound-guided injection and 95% ethanol retention are an effective therapy for the treatment of postoperative recurrent chocolate cysts. Copyright © 2011 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  12. Non-invasive pulsed cavitational ultrasound for fetal tissue ablation: feasibility study in a fetal sheep model.

    PubMed

    Kim, Y; Gelehrter, S K; Fifer, C G; Lu, J C; Owens, G E; Berman, D R; Williams, J; Wilkinson, J E; Ives, K A; Xu, Z

    2011-04-01

    Currently available fetal intervention techniques rely on invasive procedures that carry inherent risks. A non-invasive technique for fetal intervention could potentially reduce the risk of fetal and obstetric complications. Pulsed cavitational ultrasound therapy (histotripsy) is an ablation technique that mechanically fractionates tissue at the focal region using extracorporeal ultrasound. In this study, we investigated the feasibility of using histotripsy as a non-invasive approach to fetal intervention in a sheep model. The experiments involved 11 gravid sheep at 102-129 days of gestation. Fetal kidney, liver, lung and heart were exposed to ultrasound pulses (< 10 µs) delivered by an external 1-MHz focused ultrasound transducer at a 0.2-1-kHz pulse-repetition rate and 10-16 MPa peak negative pressure. Procedures were monitored and guided by real-time ultrasound imaging. Treated organs were examined by gross and histological inspection for location and degree of tissue injury. Hyperechoic, cavitating bubble clouds were successfully generated in 19/31 (61%) treatment attempts in 27 fetal organs beneath up to 8 cm of overlying tissue and fetal bones. Histological assessment confirmed lesion locations and sizes corresponding to regions where cavitation was monitored, with no lesions found when cavitation was absent. Inability to generate cavitation was primarily associated with increased depth to target and obstructing structures such as fetal limbs. Extracorporeal histotripsy therapy successfully created targeted lesions in fetal sheep organs without significant damage to overlying structures. With further improvements, histotripsy may evolve into a viable technique for non-invasive fetal intervention procedures. Copyright © 2011 ISUOG. Published by John Wiley & Sons, Ltd.

  13. Assistive technology for ultrasound-guided central venous catheter placement.

    PubMed

    Ikhsan, Mohammad; Tan, Kok Kiong; Putra, Andi Sudjana

    2018-01-01

    This study evaluated the existing technology used to improve the safety and ease of ultrasound-guided central venous catheterization. Electronic database searches were conducted in Scopus, IEEE, Google Patents, and relevant conference databases (SPIE, MICCAI, and IEEE conferences) for related articles on assistive technology for ultrasound-guided central venous catheterization. A total of 89 articles were examined and pointed to several fields that are currently the focus of improvements to ultrasound-guided procedures. These include improving needle visualization, needle guides and localization technology, image processing algorithms to enhance and segment important features within the ultrasound image, robotic assistance using probe-mounted manipulators, and improving procedure ergonomics through in situ projections of important information. Probe-mounted robotic manipulators provide a promising avenue for assistive technology developed for freehand ultrasound-guided percutaneous procedures. However, there is currently a lack of clinical trials to validate the effectiveness of these devices.

  14. The role of invasive sonography in the differential diagnosis and treatment of intraabdominal fluid collections.

    PubMed

    Regöly-Mérei, J; Ihász, M; Szeberin, Z; Záborszky, A

    Sixty-nine ultrasound-guided interventions (23 punctures and 46 drainages) were performed on 51 patients with the suspicion of intraabdominal abscess or another type of fluid collection in a prospective-controlled study. Of the procedures, 58.8% were carried out following surgery, while in 41.2% the indication were not related to prior surgical intervention. Repeated procedures were done in 10 patients. In the group of punctures the procedure was therapeutic in 3 cases and diagnostic in 16 patients. The drainage was technically successful in 92.7%. The drain was displaced or blocked in 27% (n = 10), but reinterventions were necessary in only 5 cases for this reason. The total number of redrainages was 18.9%. The percutaneous (pc) drainage was insufficient in 8 patients (21.6%), all these patients were operated on. 62.2% of the patients recovered after pc drainage, 13.5% following redrainage (total 75.5%). In 8.1% of the cases after pc drainage and in 5.4% after pc redrainage open surgery became necessary. There was only one complication due to the procedure. Seven patients (14.3%) died of the disease which indicated the procedure. There were no fatal outcomes on the account of the intervention. Ultrasound-guided puncture is a suitable method to indicate or contraindicate open surgery in the case of intraabdominal fluid collection. The diagnostic puncture may be followed by sonographically guided drainage or in selected cases by therapeutic puncture, but if the pc drainage is insufficient, open surgery should be performed in time.

  15. Single-operator real-time ultrasound-guided spinal injection using SonixGPS™: a case series.

    PubMed

    Brinkmann, Silke; Tang, Raymond; Sawka, Andrew; Vaghadia, Himat

    2013-09-01

    The SonixGPS™ is a novel needle tracking system that has recently been approved in Canada for ultrasound-guided needle interventions. It allows optimization of needle-beam alignment by providing a real-time display of current and predicted needle tip position. Currently, there is limited evidence on the effectiveness of this technique for performance of real-time spinal anesthesia. This case series reports performance of the SonixGPS system for real-time ultrasound-guided spinal anesthesia in elective patients scheduled for joint arthroplasty. In this single-centre case series, 20 American Society of Anesthesiologists' class I-II patients scheduled for lower limb joint arthroplasty were recruited to undergo real-time ultrasound-guided spinal anesthesia with the SonixGPS after written informed consent. The primary outcome for this clinical cases series was the success rate of spinal anesthesia, and the main secondary outcome was time required to perform spinal anesthesia. Successful spinal anesthesia for joint arthroplasty was achieved in 18/20 patients, and 17 of these required only a single skin puncture. In 7/20 (35%) patients, dural puncture was achieved on the first needle pass, and in 11/20 (55%) patients, dural puncture was achieved with two or three needle redirections. Median (range) time taken to perform the block was 8 (5-14) min. The study procedure was aborted in two cases because our clinical protocol dictated using a standard approach if spinal anesthesia was unsuccessful after three ultrasound-guided insertion attempts. These two cases were classified as failures. No complications, including paresthesia, were observed during the procedure. All patients with successful spinal anesthesia found the technique acceptable and were willing to undergo a repeat procedure if deemed necessary. This case series shows that real-time ultrasound-guided spinal anesthesia with the SonixGPS system is possible within an acceptable time frame. It proved effective with a low rate of failure and a low rate of complications. Our clinical experience suggests that a randomized trial is warranted to compare the SonixGPS with a standard block technique.

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ryan, E. Ronan, E-mail: ronan@ronanryan.com; Thornton, Raymond; Sofocleous, Constantinos T.

    PurposeTo quantify radiation exposure to the primary operator and staff during PET/CT-guided interventional procedures.MethodsIn this prospective study, 12 patients underwent PET/CT-guided interventions over a 6 month period. Radiation exposure was measured for the primary operator, the radiology technologist, and the nurse anesthetist by means of optically stimulated luminescence dosimeters. Radiation exposure was correlated with the procedure time and the use of in-room image guidance (CT fluoroscopy or ultrasound).ResultsThe median effective dose was 0.02 (range 0-0.13) mSv for the primary operator, 0.01 (range 0-0.05) mSv for the nurse anesthetist, and 0.02 (range 0-0.05) mSv for the radiology technologist. The median extremitymore » dose equivalent for the operator was 0.05 (range 0-0.62) mSv. Radiation exposure correlated with procedure duration and with the use of in-room image guidance. The median operator effective dose for the procedure was 0.015 mSv when conventional biopsy mode CT was used, compared to 0.06 mSv for in-room image guidance, although this did not achieve statistical significance as a result of the small sample size (p = 0.06).ConclusionThe operator dose from PET/CT-guided procedures is not significantly different than typical doses from fluoroscopically guided procedures. The major determinant of radiation exposure to the operator from PET/CT-guided interventional procedures is time spent in close proximity to the patient.« less

  17. Endoscopic ultrasound-guided transmural drainage of postoperative pancreatic collections.

    PubMed

    Tilara, Amy; Gerdes, Hans; Allen, Peter; Jarnagin, William; Kingham, Peter; Fong, Yuman; DeMatteo, Ronald; D'Angelica, Michael; Schattner, Mark

    2014-01-01

    Pancreatic leak is a major cause of morbidity after pancreatectomy. Traditionally, peripancreatic fluid collections have been managed by percutaneous or operative drainage. Data for endoscopic ultrasound (EUS)-guided drainage of postoperative fluid collections are limited. Here we report on the safety, efficacy, and timing of EUS-guided drainage of postoperative peripancreatic collections. This is a retrospective review of 31 patients who underwent EUS-guided drainage of fluid collections after pancreatic resection. Technical success was defined as successful transgastric deployment of at least one double pigtail plastic stent. Clinical success was defined as resolution of the fluid collection on follow-up CT scan and resolution of symptoms. Early drainage was defined as initial transmural stent placement within 30 days after surgery. Endoscopic ultrasound-guided drainage was performed effectively with a technical success rate of 100%. Clinical success was achieved in 29 of 31 patients (93%). Nineteen of the 29 patients (65%) had complete resolution of their symptoms and collection with the first endoscopic procedure. Repeat drainage procedures, including some with necrosectomy, were required in the remaining 10 patients, with eventual resolution of collection and symptoms. Two patients who did not achieve durable clinical success required percutaneous drainage by interventional radiology. Seventeen (55%) of 31 patients had successful early drainage completed within 30 days of their operation. Endoscopic ultrasound-guided drainage of fluid collections after pancreatic resection is safe and effective. Early drainage (<30 days) of postoperative pancreatic fluid collections was not associated with increased complications in this series. Copyright © 2014 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  18. Thirty-day emergency room visits and hospital admissions after outpatient non-vascular image-guided procedures.

    PubMed

    Nguyen, Quang; Mehta, Sahil V; Fang, Jieming; Sheiman, Robert; Kane, Robert; Ahmed, Muneeb; Sarwar, Ammar; Siewert, Bettina; Brook, Olga R

    2017-10-01

    To evaluate the rate of post-procedure emergency department (ED) visits and hospital admissions following outpatient non-vascular image-guided interventions performed under moderate sedation and to identify common and preventable causes of emergency department visits and hospital admissions. Institutional review board approval was acquired for this HIPAA-compliant retrospective study with waiver of informed consent. 1426 consecutive patients undergoing 1512 outpatient image-guided procedures under moderate sedation from November 2012 to August 2014 were included. The average patient age was 57.2 ± 15.2 years, and 602 (42%) patients were women. Major procedure categories included ultrasound-guided liver biopsies, ultrasound-guided kidney biopsies, and CT-guided lung biopsies/fiducial placement. Procedure details and medical follow-up within and after 30 days of the procedure were analyzed. A total of 168 (11.8%) patients were admitted to the hospital within 30 days of the procedure, with 29 of the admissions (17.3% of total admissions and 1.9% of total procedures) being procedure related. The most common procedure-related complication that required admission was hemorrhage (10/29, 34.5% of procedure-related admissions, 6.0% of total admissions, and 0.7% of total procedures), followed by pneumothorax (9/29, 31%, 5.4%, 0.6%), infection (4/29, 13.8%, 2.4%, 0.3%), and pain (3/29, 10.3%, 1.8%, 0.2%). Eighteen (62.1%) procedure-related admissions were immediately indicated. Thirty patients visited the ED and were subsequently discharged without admission with eight of the visits being procedure related (8/1512, 0.5%). All the procedure-related ED visits were due to pain. There were two deaths (2/1512, 0.1%) related to procedures, one from a thromboembolic event and another from post-biopsy hemorrhage. Outpatient non-vascular image-guided procedures result in a 30-day 1.9% hospital admission, 30-day 0.5% emergency room visit, and 30-day 0.1% mortality rate.

  19. Ultrasound-guided steroid tendon sheath injections in juvenile idiopathic arthritis: a 10-year single-center retrospective study.

    PubMed

    Peters, Shannon E; Laxer, Ronald M; Connolly, Bairbre L; Parra, Dimitri A

    2017-04-11

    The aims of this study were to: (a) Identify tendon sheaths most commonly treated with steroid injections in a pediatric patient population with Juvenile Idiopathic Arthritis (JIA); (b) Describe technical aspects of the procedure; (c) Characterize sonographic appearance of tenosynovitis in JIA; (d) Assess agreement between clinical request and sites injected. This was a 10 year single-center retrospective study (May 2006-April 2016) of patients with JIA referred by Rheumatology for ultrasound-guided tendon sheath injections. Patient demographics, clinical referral information, sonographic appearance of the tendon sheaths and technical aspects of the procedure were analyzed. There were 308 procedures of 244 patients (75% female, mean age 9.6 years) who underwent a total of 926 tendon sheath injections. Ankle tendons were most commonly injected (84.9%), specifically the tendon sheaths of tibialis posterior (22.3%), peroneus longus (20%) and brevis (19.7%). The majority of treated sites (91.9%) showed peritendinous fluid and sheath thickening on ultrasound. There were 2 minor intra-procedure complications without sequelae. A good agreement between clinical request and sites injected was observed. Ultrasound-guided tendon sheath injections with steroids are used frequently to treat patients with JIA. It is a safe intervention with a high technical success rate. The ankle region, specifically the medial compartment, is the site most commonly injected in this group of patients. The most common sonographic finding is peritendinous fluid and sheath thickening. These findings might assist clinicians and radiologists to characterize and more effectively manage tenosynovitis in patients with JIA.

  20. Ultrasound-guided versus computed tomography-scan guided biopsy of pleural-based lung lesions

    PubMed Central

    Khosla, Rahul; McLean, Anna W; Smith, Jessica A

    2016-01-01

    Background: Computed tomography (CT) guided biopsies have long been the standard technique to obtain tissue from the thoracic cavity and is traditionally performed by interventional radiologists. Ultrasound (US) guided biopsy of pleural-based lesions, performed by pulmonologists is gaining popularity and has the advantage of multi-planar imaging, real-time technique, and the absence of radiation exposure to patients. In this study, we aim to determine the diagnostic accuracy, the time to diagnosis after the initial consult placement, and the complications rates between the two different modalities. Methods: A retrospective study of electronic medical records was done of patients who underwent CT-guided biopsies and US-guided biopsies for pleural-based lesions between 2005 and 2014 and the data collected were analyzed for comparing the two groups. Results: A total of 158 patients underwent 162 procedures during the study period. 86 patients underwent 89 procedures in the US group, and 72 patients underwent 73 procedures in the CT group. The overall yield in the US group was 82/89 (92.1%) versus 67/73 (91.8%) in the CT group (P = 1.0). Average days to the procedure was 7.2 versus 17.5 (P = 0.00001) in the US and CT group, respectively. Complication rate was higher in CT group 17/73 (23.3%) versus 1/89 (1.1%) in the US group (P < 0.0001). Conclusions: For pleural-based lesions the diagnostic accuracy of US guided biopsy is similar to that of CT-guided biopsy, with a lower complication rate and a significantly reduced time to the procedure. PMID:27625440

  1. Treatment of proximal hamstring tendinopathy-related sciatic nerve entrapment: presentation of an ultrasound-guided "Intratissue Percutaneous Electrolysis" application.

    PubMed

    Mattiussi, Gabriele; Moreno, Carlos

    2016-01-01

    Proximal Hamstring Tendinopathy-related Sciatic Nerve Entrapment (PHTrSNE) is a neuropathy caused by fibrosis interposed between the semimembranosus tendon and the sciatic nerve, at the level of the ischial tuberosity. Ultrasound-guided Intratissue Percutaneous Electrolysis (US-guided EPI) involves galvanic current transfer within the treatment target tissue (fibrosis) via a needle 0.30 to 0.33 mm in diameter. The galvanic current in a saline solution instantly develops the chemical process of electrolysis, which in turn induces electrochemical ablation of fibrosis. In this article, the interventional procedure is presented in detail, and both the strengths and limits of the technique are discussed. US-guided EPI eliminates the fibrotic accumulation that causes PHTrSNE, without the semimembranosus tendon or the sciatic nerve being directly involved during the procedure. The technique is however of limited use in cases of compression neuropathy. US-guided EPI is a technique that is quick to perform, minimally invasive and does not force the patient to suspend their activities (work or sports) to make the treatment effective. This, coupled to the fact that the technique is generally well-tolerated by patients, supports use of US-guided EPI in the treatment of PHTrSNE.

  2. Ultrasound-guided synovial biopsy

    PubMed Central

    Sitt, Jacqueline C M; Wong, Priscilla

    2016-01-01

    Ultrasound-guided needle biopsy of synovium is an increasingly performed procedure with a high diagnostic yield. In this review, we discuss the normal synovium, as well as the indications, technique, tissue handling and clinical applications of ultrasound-guided synovial biopsy. PMID:26581578

  3. Effects of line fiducial parameters and beamforming on ultrasound calibration

    PubMed Central

    Ameri, Golafsoun; Baxter, John S. H.; McLeod, A. Jonathan; Peters, Terry M.; Chen, Elvis C. S.

    2017-01-01

    Abstract. Ultrasound (US)-guided interventions are often enhanced via integration with an augmented reality environment, a necessary component of which is US calibration. Calibration requires the segmentation of fiducials, i.e., a phantom, in US images. Fiducial localization error (FLE) can decrease US calibration accuracy, which fundamentally affects the total accuracy of the interventional guidance system. Here, we investigate the effects of US image reconstruction techniques as well as phantom material and geometry on US calibration. It was shown that the FLE was reduced by 29% with synthetic transmit aperture imaging compared with conventional B-mode imaging in a Z-bar calibration, resulting in a 10% reduction of calibration error. In addition, an evaluation of a variety of calibration phantoms with different geometrical and material properties was performed. The phantoms included braided wire, plastic straws, and polyvinyl alcohol cryogel tubes with different diameters. It was shown that these properties have a significant effect on calibration error, which is a variable based on US beamforming techniques. These results would have important implications for calibration procedures and their feasibility in the context of image-guided procedures. PMID:28331886

  4. Effects of line fiducial parameters and beamforming on ultrasound calibration.

    PubMed

    Ameri, Golafsoun; Baxter, John S H; McLeod, A Jonathan; Peters, Terry M; Chen, Elvis C S

    2017-01-01

    Ultrasound (US)-guided interventions are often enhanced via integration with an augmented reality environment, a necessary component of which is US calibration. Calibration requires the segmentation of fiducials, i.e., a phantom, in US images. Fiducial localization error (FLE) can decrease US calibration accuracy, which fundamentally affects the total accuracy of the interventional guidance system. Here, we investigate the effects of US image reconstruction techniques as well as phantom material and geometry on US calibration. It was shown that the FLE was reduced by 29% with synthetic transmit aperture imaging compared with conventional B-mode imaging in a Z-bar calibration, resulting in a 10% reduction of calibration error. In addition, an evaluation of a variety of calibration phantoms with different geometrical and material properties was performed. The phantoms included braided wire, plastic straws, and polyvinyl alcohol cryogel tubes with different diameters. It was shown that these properties have a significant effect on calibration error, which is a variable based on US beamforming techniques. These results would have important implications for calibration procedures and their feasibility in the context of image-guided procedures.

  5. 3D ultrasound imaging in image-guided intervention.

    PubMed

    Fenster, Aaron; Bax, Jeff; Neshat, Hamid; Cool, Derek; Kakani, Nirmal; Romagnoli, Cesare

    2014-01-01

    Ultrasound imaging is used extensively in diagnosis and image-guidance for interventions of human diseases. However, conventional 2D ultrasound suffers from limitations since it can only provide 2D images of 3-dimensional structures in the body. Thus, measurement of organ size is variable, and guidance of interventions is limited, as the physician is required to mentally reconstruct the 3-dimensional anatomy using 2D views. Over the past 20 years, a number of 3-dimensional ultrasound imaging approaches have been developed. We have developed an approach that is based on a mechanical mechanism to move any conventional ultrasound transducer while 2D images are collected rapidly and reconstructed into a 3D image. In this presentation, 3D ultrasound imaging approaches will be described for use in image-guided interventions.

  6. Real-time ultrasound-guided spinal anesthesia using the SonixGPS® needle tracking system: a case report.

    PubMed

    Wong, Simon W; Niazi, Ahtsham U; Chin, Ki J; Chan, Vincent W

    2013-01-01

    The SonixGPS® is an electromagnetic needle tracking system for ultrasound-guided needle intervention. Both current and predicted needle tip position are displayed on the ultrasound screen in real-time, facilitating needle-beam alignment and guidance to the target. This case report illustrates the use of the SonixGPS system for successful performance of real-time ultrasound-guided spinal anesthesia in a patient with difficult spinal anatomy. A 67-yr-old male was admitted to our hospital to undergo revision of total right hip arthroplasty. His four previous arthroplasties for hip revision were performed under general anesthesia because he had undergone L3-L5 instrumentation for spinal stenosis. The L4-L5 interspace was viewed with the patient in the left lateral decubitus position. A 19G 80-mm proprietary needle (Ultrasonix Medical Corp, Richmond, BC, Canada) was inserted and directed through the paraspinal muscles to the ligamentum flavum in plane to the ultrasound beam. A 120-mm 25G Whitacre spinal needle was then inserted through the introducer needle in a conventional fashion. Successful dural puncture was achieved on the second attempt, as indicated by a flow of clear cerebrospinal fluid. The patient tolerated the procedure well, and the spinal anesthetic was adequate for the duration of the surgery. The SonixGPS is a novel technology that can reduce the technical difficulty of real-time ultrasound-guided neuraxial blockade. It may also have applications in other advanced ultrasound-guided regional anesthesia techniques where needle-beam alignment is critical.

  7. Greater physician involvement improves coding outcomes in endobronchial ultrasound-guided transbronchial needle aspiration procedures.

    PubMed

    Pillai, Anilkumar; Medford, Andrew R L

    2013-01-01

    Correct coding is essential for accurate reimbursement for clinical activity. Published data confirm that significant aberrations in coding occur, leading to considerable financial inaccuracies especially in interventional procedures such as endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA). Previous data reported a 15% coding error for EBUS-TBNA in a U.K. service. We hypothesised that greater physician involvement with coders would reduce EBUS-TBNA coding errors and financial disparity. The study was done as a prospective cohort study in the tertiary EBUS-TBNA service in Bristol. 165 consecutive patients between October 2009 and March 2012 underwent EBUS-TBNA for evaluation of unexplained mediastinal adenopathy on computed tomography. The chief coder was prospectively electronically informed of all procedures and cross-checked on a prospective database and by Trust Informatics. Cost and coding analysis was performed using the 2010-2011 tariffs. All 165 procedures (100%) were coded correctly as verified by Trust Informatics. This compares favourably with the 14.4% coding inaccuracy rate for EBUS-TBNA in a previous U.K. prospective cohort study [odds ratio 201.1 (1.1-357.5), p = 0.006]. Projected income loss was GBP 40,000 per year in the previous study, compared to a GBP 492,195 income here with no coding-attributable loss in revenue. Greater physician engagement with coders prevents coding errors and financial losses which can be significant especially in interventional specialties. The intervention can be as cheap, quick and simple as a prospective email to the coding team with cross-checks by Trust Informatics and against a procedural database. We suggest that all specialties should engage more with their coders using such a simple intervention to prevent revenue losses. Copyright © 2013 S. Karger AG, Basel.

  8. Development of a 3D ultrasound-guided system for thermal ablation of liver tumors

    NASA Astrophysics Data System (ADS)

    Neshat, Hamid R. S.; Cool, Derek W.; Barker, Kevin; Gardi, Lori; Kakani, Nirmal; Fenster, Aaron

    2013-03-01

    Two-dimensional ultrasound (2D US) imaging is commonly used for diagnostic and intraoperative guidance of interventional abdominal procedures including percutaneous thermal ablation of focal liver tumors with radiofrequency (RF) or microwave (MW) induced energy. However, in many situations 2D US may not provide enough anatomical detail and guidance information. Therefore, intra-procedural CT or MR imaging are used in many centers for guidance purposes. These modalities are costly and are mainly utilized to confirm tool placement rather than guiding the insertion. Three-dimensional ultrasound (3D US) has been introduced to address these issues. In this paper, we present our integrated solution to provide 3D US images using a newly developed mechanical transducer with a large field-ofview and without the need for external tracking devices to combine diagnostic and planning information of different modalities for intraoperative guidance. The system provides tools to segment the target(s), plan the treatment, and detect the ablation applicators during the procedure for guiding purposes. We present experimental results used to ensure that our system generates accurate measurements and our early clinical evaluation results. The results suggest that 3D US used for focal liver ablation can provide a more reliable planning and guidance tool compared to 2D US only, and in many cases offers comparable measurements to other alternatives at significantly lower cost, faster time and with no harmful radiation.

  9. New platform for evaluating ultrasound-guided interventional technologies

    NASA Astrophysics Data System (ADS)

    Kim, Younsu; Guo, Xiaoyu; Boctor, Emad M.

    2016-04-01

    Ultrasound-guided needle tracking systems are frequently used in surgical procedures. Various needle tracking technologies have been developed using ultrasound, electromagnetic sensors, and optical sensors. To evaluate these new needle tracking technologies, 3D volume information is often acquired to compute the actual distance from the needle tip to the target object. The image-guidance conditions for comparison are often inconsistent due to the ultrasound beam-thickness. Since 3D volumes are necessary, there is often some time delay between the surgical procedure and the evaluation. These evaluation methods will generally only measure the final needle location because they interrupt the surgical procedure. The main contribution of this work is a new platform for evaluating needle tracking systems in real-time, resolving the problems stated above. We developed new tools to evaluate the precise distance between the needle tip and the target object. A PZT element transmitting unit is designed as needle introducer shape so that it can be inserted in the needle. We have collected time of flight and amplitude information in real-time. We propose two systems to collect ultrasound signals. We demonstrate this platform on an ultrasound DAQ system and a cost-effective FPGA board. The results of a chicken breast experiment show the feasibility of tracking a time series of needle tip distances. We performed validation experiments with a plastisol phantom and have shown that the preliminary data fits a linear regression model with a RMSE of less than 0.6mm. Our platform can be applied to more general needle tracking methods using other forms of guidance.

  10. Percutaneous imaging-guided interventions for acute biliary disorders in high surgical risk patients

    PubMed Central

    Donkol, Ragab Hani; Latif, Nahed Abdel; Moghazy, Khaled

    2010-01-01

    AIM: To evaluate the efficacy of percutaneous imaging-guided biliary interventions in the management of acute biliary disorders in high surgical risk patients. METHODS: One hundred and twenty two patients underwent 139 percutaneous imaging-guided biliary interventions during the period between January 2007 to December 2009. The patients included 73 women and 49 men with a mean age of 61 years (range 35-90 years). Fifty nine patients had acute biliary obstruction, 26 patients had acute biliary infection and 37 patients had abnormal collections. The procedures were performed under computed tomography (CT)- (73 patients), sonographic- (41 patients), and fluoroscopic-guidance (25 patients). Success rates and complications were determined. The χ2 test with Yates’ correction for continuity was applied to compare between these procedures. A P value < 0.05 was considered significant. RESULTS: The success rates for draining acute biliary obstruction under CT- , fluoroscopy- or ultrasound-guidance were 93.3%, 62.5% and 46.1%, respectively with significant P values (P = 0.026 and 0.002, respectively). In acute biliary infection, successful drainage was achieved in 22 patients (84.6%). The success rates in patients drained under ultrasound- and CT-guidance were 46.1% and 88.8%, respectively and drainage under CT-guidance was significantly higher (P = 0.0293). In 13 patients with bilomas, percutaneous drainage was successful in 11 patients (84.6%). Ten out of 12 cases with hepatic abscesses were drained with a success rate of 83.3%. In addition, the success rate of drainage in 12 cases with pancreatic pseudocysts was 83.3%. The reported complications were two deaths, four major and seven minor complications. CONCLUSION: Percutaneous imaging-guided biliary interventions help to promptly diagnose and effectively treat acute biliary disorders. They either cure the disorders or relieve sepsis and jaundice before operations. PMID:21160698

  11. Two-dimensional mapping of needle visibility with linear and curved array for ultrasound-guided interventional procedure

    NASA Astrophysics Data System (ADS)

    Susanti, Hesty; Suprijanto, Kurniadi, Deddy

    2018-02-01

    Needle visibility in ultrasound-guided technique has been a crucial factor for successful interventional procedure. It has been affected by several factors, i.e. puncture depth, insertion angle, needle size and material, and imaging technology. The influences of those factors made the needle not always well visible. 20 G needles of 15 cm length (Nano Line, facet) were inserted into water bath with variation of insertion angles and depths. Ultrasound measurements are performed with BK-Medical Flex Focus 800 using 12 MHz linear array and 5 MHz curved array in Ultrasound Guided Regional Anesthesia mode. We propose 3 criteria to evaluate needle visibility, i.e. maximum intensity, mean intensity, and the ratio between minimum and maximum intensity. Those criteria were then depicted into representative maps for practical purpose. The best criterion candidate for representing the needle visibility was criterion 1. Generally, the appearance pattern of the needle from this criterion was relatively consistent, i.e. for linear array, it was relatively poor visibility in the middle part of the shaft, while for curved array, it is relatively better visible toward the end of the shaft. With further investigations, for example with the use of tissue-mimicking phantom, the representative maps can be built for future practical purpose, i.e. as a tool for clinicians to ensure better needle placement in clinical application. It will help them to avoid the "dead" area where the needle is not well visible, so it can reduce the risks of vital structures traversing and the number of required insertion, resulting in less patient morbidity. Those simple criteria and representative maps can be utilized to evaluate general visibility patterns of the needle in vast range of needle types and sizes in different insertion media. This information is also important as an early investigation for future research of needle visibility improvement, i.e. the development of beamforming strategies and ultrasound enhanced (echogenic) needle.

  12. Success of ultrasound-guided versus landmark-guided arthrocentesis of hip, ankle, and wrist in a cadaver model.

    PubMed

    Berona, Kristin; Abdi, Amin; Menchine, Michael; Mailhot, Tom; Kang, Tarina; Seif, Dina; Chilstrom, Mikaela

    2017-02-01

    The objectives of this study were to evaluate emergency medicine resident-performed ultrasound for diagnosis of effusions, compare the success of a landmark-guided (LM) approach with an ultrasound-guided (US) technique for hip, ankle and wrist arthrocentesis, and compare change in provider confidence with LM and US arthrocentesis. After a brief video on LM and US arthrocentesis, residents were asked to identify artificially created effusions in the hip, ankle and wrist in a cadaver model and to perform US and LM arthrocentesis of the effusions. Outcomes included success of joint aspiration, time to aspiration, and number of attempts. Residents were surveyed regarding their confidence in identifying effusions with ultrasound and performing LM and US arthrocentesis. Eighteen residents completed the study. Sensitivity of ultrasound for detecting joint effusion was 86% and specificity was 90%. Residents were successful with ultrasound in 96% of attempts and with landmark 89% of attempts (p=0.257). Median number of attempts was 1 with ultrasound and 2 with landmarks (p=0.12). Median time to success with ultrasound was 38s and 51s with landmarks (p=0.23). After the session, confidence in both US and LM arthrocentesis improved significantly, however the post intervention confidence in US arthrocentesis was higher than LM (4.3 vs. 3.8, p<0.001). EM residents were able to successfully identify joint effusions with ultrasound, however we were unable to detect significant differences in actual procedural success between the two modalities. Further studies are needed to define the role of ultrasound for arthrocentesis in the emergency department. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. State of education regarding ultrasound-guided interventions during pain fellowships in Korea: a survey of recent fellows

    PubMed Central

    Kim, Hyung Tae; Kim, Sae Young; Byun, Gyung Jo; Shin, Byung Chul; Lee, Jin Young; Choi, Eun Joo; Choi, Jong Bum; Hong, Ji Hee; Choi, Seung Won

    2017-01-01

    Background Recently, the use of ultrasound (US) techniques in regional anesthesia and pain medicine has increased significantly. However, the current extent of training in the use of US-guided pain management procedures in Korea remains unknown. The purpose of the present study was to assess the current state of US training provided during Korean Pain Society (KPS) pain fellowship programs through the comparative analysis between training hospitals. Methods We conducted an anonymous survey of 51 pain physicians who had completed KPS fellowships in 2017. Items pertained to current US practices and education, as well as the types of techniques and amount of experience with US-guided pain management procedures. Responses were compared based on the tier of the training hospital. Results Among the 51 respondents, 14 received training at first- and second-tier hospitals (Group A), while 37 received training at third-tier hospitals (Group B). The mean total duration of pain training during the 1-year fellowship was 7.4 months in Group A and 8.4 months in Group B. Our analysis revealed that 36% and 40% of respondents in Groups A and B received dedicated US training, respectively. Most respondents underwent US training in patient-care settings under the supervision of attending physicians. Cervical root, stellate ganglion, piriformis, and lumbar plexus blocks were more commonly performed by Group B than by Group A (P < 0.05). Conclusions Instruction regarding US-guided pain management interventions varied among fellowship training hospitals, highlighting the need for the development of educational standards that mandate a minimum number of US-guided nerve blocks or injections during fellowships in interventional pain management. PMID:29123624

  14. Development and preliminary evaluation of an ultrasonic motor actuated needle guide for 3T MRI-guided transperineal prostate interventions

    NASA Astrophysics Data System (ADS)

    Song, Sang-Eun; Tokuda, Junichi; Tuncali, Kemal; Tempany, Clare; Hata, Nobuhiko

    2012-02-01

    Image guided prostate interventions have been accelerated by Magnetic Resonance Imaging (MRI) and robotic technologies in the past few years. However, transrectal ultrasound (TRUS) guided procedure still remains as vast majority in clinical practice due to engineering and clinical complexity of the MRI-guided robotic interventions. Subsequently, great advantages and increasing availability of MRI have not been utilized at its maximum capacity in clinic. To benefit patients from the advantages of MRI, we developed an MRI-compatible motorized needle guide device "Smart Template" that resembles a conventional prostate template to perform MRI-guided prostate interventions with minimal changes in the clinical procedure. The requirements and specifications of the Smart Template were identified from our latest MRI-guided intervention system that has been clinically used in manual mode for prostate biopsy. Smart Template consists of vertical and horizontal crossbars that are driven by two ultrasonic motors via timing-belt and mitergear transmissions. Navigation software that controls the crossbar position to provide needle insertion positions was also developed. The software can be operated independently or interactively with an open-source navigation software, 3D Slicer, that has been developed for prostate intervention. As preliminary evaluation, MRI distortion and SNR test were conducted. Significant MRI distortion was found close to the threaded brass alloy components of the template. However, the affected volume was limited outside the clinical region of interest. SNR values over routine MRI scan sequences for prostate biopsy indicated insignificant image degradation during the presence of the robotic system and actuation of the ultrasonic motors.

  15. Preliminary study of ergonomic behavior during simulated ultrasound-guided regional anesthesia using a head-mounted display.

    PubMed

    Udani, Ankeet D; Harrison, T Kyle; Howard, Steven K; Kim, T Edward; Brock-Utne, John G; Gaba, David M; Mariano, Edward R

    2012-08-01

    A head-mounted display provides continuous real-time imaging within the practitioner's visual field. We evaluated the feasibility of using head-mounted display technology to improve ergonomics in ultrasound-guided regional anesthesia in a simulated environment. Two anesthesiologists performed an equal number of ultrasound-guided popliteal-sciatic nerve blocks using the head-mounted display on a porcine hindquarter, and an independent observer assessed each practitioner's ergonomics (eg, head turning, arching, eye movements, and needle manipulation) and the overall block quality based on the injectate spread around the target nerve for each procedure. Both practitioners performed their procedures without directly viewing the ultrasound monitor, and neither practitioner showed poor ergonomic behavior. Head-mounted display technology may offer potential advantages during ultrasound-guided regional anesthesia.

  16. The effects of hypnotherapy during transrectal ultrasound-guided prostate needle biopsy for pain and anxiety.

    PubMed

    Hızlı, Fatih; Özcan, Osman; Selvi, İsmail; Eraslan, Pınar; Köşüş, Aydın; Baş, Okan; Yıkılmaz, Taha Numan; Güven, Oğuz; Başar, Halil

    2015-11-01

    Several studies evaluating the tolerance of transrectal ultrasound (TRUS)-guided needle biopsies showed that moderate-to-severe pain was associated with the procedure. Additionally, prebiopsy anxiety or rebiopsy as a result of a prior biopsy procedure is mentioned as factors predisposing to higher pain intensity. Thus, in this study, we investigated the effects of hypnotherapy during transrectal ultrasound-guided prostate needle biopsy for pain and anxiety. Sixty-four patients presenting for TRUS-guided prostate needle biopsy were randomly assigned to receive either 10-min presurgery hypnosis session (n = 32, mean age 63.5 ± 6.1, p = 0.289) or a presurgery control session (n = 32, mean age 61.8 ± 6.8, p = 0.289). The hypnosis session involved suggestions for increased relaxation and decreased anxiety. Presurgery pain and anxiety were measured using visual analog scales (VAS), Beck Anxiety Inventory (BAI), and Hamilton Anxiety Scale (HAS), respectively. In our statistics, p < 0.05 was considered statistically significant. Postintervention, and before surgery, patients in the hypnosis group had significantly lower mean values for presurgery VAS [mean 1 (0-8); p = 0.011], BAI (6.0 vs 2.0; p < 0.001), and HAS (11.0 vs 6.0; p < 0.001). The study results indicate that a brief presurgery hypnosis intervention can be an effective means of controlling presurgical anxiety, and therefore pain, in patients awaiting diagnostic prostate cancer surgery.

  17. Pre-procedure ultrasound-guided paramedian spinal anaesthesia at L5–S1: Is this better than landmark-guided midline approach? A randomised controlled trial

    PubMed Central

    Srinivasan, Karthikeyan Kallidaikurichi; Leo, Anne-Marie; Iohom, Gabriella; Loughnane, Frank; Lee, Peter J

    2018-01-01

    Background and Aims: Routine use of pre-procedural ultrasound guided midline approach has not shown to improve success rate in administering subarachnoid block. The study hypothesis was that the routine use of pre-procedural (not real time) ultrasound-guided paramedian spinals at L5-S1 interspace could reduce the number of passes (i.e., withdrawal and redirection of spinal needle without exiting the skin) required to enter the subarachnoid space when compared to the conventional landmark-guided midline approach. Methods: After local ethics approval, 120 consenting patients scheduled for elective total joint replacements (Hip and Knee) were randomised into either Group C where conventional midline approach with palpated landmarks was used or Group P where pre-procedural ultrasound was used to perform subarachnoid block by paramedian approach at L5-S1 interspace (real time ultrasound guidance was not used). Results: There was no difference in primary outcome (difference in number of passes) between the two groups. Similarly there was no difference in the number of attempts (i.e., the number of times the spinal needle was withdrawn from the skin and reinserted). The first pass success rates (1 attempt and 1 pass) was significantly greater in Group C compared to Group P [43% vs. 22%, P = 0.02]. Conclusion: Routine use of paramedian spinal anaesthesia at L5-S1 interspace, guided by pre-procedure ultrasound, in patients undergoing lower limb joint arthroplasties did not reduce the number of passes or attempts needed to achieve successful dural puncture. PMID:29416151

  18. Bedside ultrasound training using web-based e-learning and simulation early in the curriculum of residents.

    PubMed

    Beaulieu, Yanick; Laprise, Réjean; Drolet, Pierre; Thivierge, Robert L; Serri, Karim; Albert, Martin; Lamontagne, Alain; Bélliveau, Marc; Denault, André-Yves; Patenaude, Jean-Victor

    2015-01-01

    Focused bedside ultrasound is rapidly becoming a standard of care to decrease the risks of complications related to invasive procedures. The purpose of this study was to assess whether adding to the curriculum of junior residents an educational intervention combining web-based e-learning and hands-on training would improve the residents' proficiency in different clinical applications of bedside ultrasound as compared to using the traditional apprenticeship teaching method alone. Junior residents (n = 39) were provided with two educational interventions (vascular and pleural ultrasound). Each intervention consisted of a combination of web-based e-learning and bedside hands-on training. Senior residents (n = 15) were the traditionally trained group and were not provided with the educational interventions. After the educational intervention, performance of the junior residents on the practical tests was superior to that of the senior residents. This was true for the vascular assessment (94% ± 5% vs. 68% ± 15%, unpaired student t test: p < 0.0001, mean difference: 26 (95% CI: 20 to 31)) and even more significant for the pleural assessment (92% ± 9% vs. 57% ± 25%, unpaired student t test: p < 0.0001, mean difference: 35 (95% CI: 23 to 44)). The junior residents also had a significantly higher success rate in performing ultrasound-guided needle insertion compared to the senior residents for both the transverse (95% vs. 60%, Fisher's exact test p = 0.0048) and longitudinal views (100% vs. 73%, Fisher's exact test p = 0.0055). Our study demonstrated that a structured curriculum combining web-based education, hands-on training, and simulation integrated early in the training of the junior residents can lead to better proficiency in performing ultrasound-guided techniques compared to the traditional apprenticeship model.

  19. Treatment of proximal hamstring tendinopathy-related sciatic nerve entrapment: presentation of an ultrasound-guided “Intratissue Percutaneous Electrolysis” application

    PubMed Central

    Mattiussi, Gabriele; Moreno, Carlos

    2016-01-01

    Summary Background Proximal Hamstring Tendinopathy-related Sciatic Nerve Entrapment (PHTrSNE) is a neuropathy caused by fibrosis interposed between the semimembranosus tendon and the sciatic nerve, at the level of the ischial tuberosity. Methods Ultrasound-guided Intratissue Percutaneous Electrolysis (US-guided EPI) involves galvanic current transfer within the treatment target tissue (fibrosis) via a needle 0.30 to 0.33 mm in diameter. The galvanic current in a saline solution instantly develops the chemical process of electrolysis, which in turn induces electrochemical ablation of fibrosis. In this article, the interventional procedure is presented in detail, and both the strengths and limits of the technique are discussed. Results US-guided EPI eliminates the fibrotic accumulation that causes PHTrSNE, without the semimembranosus tendon or the sciatic nerve being directly involved during the procedure. The technique is however of limited use in cases of compression neuropathy. Conclusion US-guided EPI is a technique that is quick to perform, minimally invasive and does not force the patient to suspend their activities (work or sports) to make the treatment effective. This, coupled to the fact that the technique is generally well-tolerated by patients, supports use of US-guided EPI in the treatment of PHTrSNE. PMID:27900300

  20. Duplex-guided percutaneous transluminal angioplasty in iliac arterial occlusive disease.

    PubMed

    Krasznai, A G; Sigterman, T A; Welten, R J; Heijboer, R; Sikkink, C J J M; van de Akker, L H J M; Bouwman, L H

    2013-11-01

    Chronic renal insufficiency (CRI) is a growing global problem. PTA can be performed without nephrotoxic contrast, utilizing Doppler-ultrasound (Duplex) guidance. Duplex-guided infra-inguinal interventions and access-related interventions have been reported. Duplex-guided iliac interventions have not been performed to any extent because of the anatomic location. In our study we evaluated the safety and efficacy of Duplex-guided percutaneous transluminal angioplasty (DuPTA) in iliac arteries. From June 2012 until February 2013, 31 patients (35 iliac lesions), underwent DuPTA. Indications ranged from Rutherford 3 to 5. Preoperative evaluation included Ankle Brachial Index (ABI), Duplex and MRA. Procedural success was defined as crossing the lesion with a guidewire and dilating or stenting the lesion. Clinical success was defined as 50% reduction in peak systolic velocity (PSV) or clinical improvement. PSV was evaluated after PTA, then at 2 weeks. Clinical results were assessed 2 weeks after the procedure. Procedural success was achieved in 94% of patients (33/35), all of whom also had clinical success. Post-procedural PSV reduction showed an average improvement of 63% (431 cm/s to 153 cm/s). Mean preoperative ABI was 0.72 and improved to 0.88 postoperatively. PTA using Duplex-guidance in significant iliac stenosis is a safe method with major advantages in patients at high risk for developing contrast-induced nephropathy. Copyright © 2013 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  1. Ultrasound-Guided Treatment of Peripheral Nerve Pathology.

    PubMed

    Dettori, Nathan; Choudur, Hema; Chhabra, Avneesh

    2018-07-01

    High-resolution ultrasound serves as a fast, accessible, reliable, and radiation-free tool for anatomical and dynamic evaluation of various peripheral nerves. It can be used not only to identify and diagnose peripheral nerve and perineural pathology accurately but also to guide various nerve and perineural interventions. We describe the normal and pathologic appearances of peripheral nerves, the pathologies commonly affecting the individual peripheral nerves, and the current ultrasound-guided peripheral nerve interventions and techniques. Future directions are also highlighted. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  2. Safety of ultrasound-guided high-intensity focused ultrasound ablation for diffuse adenomyosis: A retrospective cohort study.

    PubMed

    Feng, Yujie; Hu, Liang; Chen, Wenzhi; Zhang, Rong; Wang, Xi; Chen, Jinyun

    2017-05-01

    To evaluate the safety of ultrasound-guided high-intensity focused ultrasound (HIFU) ablation for patients with diffuse adenomyosis. This was a retrospective cohort study. The data was collected from 417 symptomatic adenomyosis patients who underwent ultrasound-guided HIFU between January 2012 and December 2015 at 1st Affiliated Hospital of Chongqing Medical University, Chongqing, China. Among them were 260 patients with diffuse adenomyosis (Group D) and 157 patients with focal adenomyosis (Group F). All patients underwent contrast-enhanced magnetic resonance imaging (MRI) one week before and the day after HIFU treatment. Successful treatment with HIFU was measured by the non-perfused volume ratio (NPVR). Intraprocedural and postprocedural adverse effects and complications were recorded to assess the safety of the procedure. Patients were followed-up for three months post-treatment. Complications were given a grade A through F according to the SIR Standards. All patients successfully completed the procedure, non-perfused regions appeared in 415 (99.5%) patients. The non-perfused volume ratio (NPVR) of Group D was significantly lower than that of Group F (P<0.05). During the procedure, the odds ratio of skin-burning pain was 1.7 (OR=1.617, 95% CI: 1.103-2.532), when comparing Group D with Group F, while the odds ratio of inguinal pain was equal to 2.0 (OR=2.038, 95% CI: 1.161-3.580), when Group F was compared to Group D. 97 patients (23.3%) received nominal therapy due to complications ([Society of interventional radiology, SIR]-B grade), among them, there were 62 cases (23.8%) in Group D and 35 cases (22.3%) in Group F. No significant difference was found between the two groups (P>0.05) and neither of the reported complications of SIR-C-SIR-F occurred within the two groups. Based on our results, ultrasound-guided HIFU is safe for the treatment of diffuse adenomyosis, and controlling the ablation zone is crucial to ensure patients' safety. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Interventional robotic systems: Applications and technology state-of-the-art

    PubMed Central

    CLEARY, KEVIN; MELZER, ANDREAS; WATSON, VANCE; KRONREIF, GERNOT; STOIANOVICI, DAN

    2011-01-01

    Many different robotic systems have been developed for invasive medical procedures. In this article we will focus on robotic systems for image-guided interventions such as biopsy of suspicious lesions, interstitial tumor treatment, or needle placement for spinal blocks and neurolysis. Medical robotics is a young and evolving field and the ultimate role of these systems has yet to be determined. This paper presents four interventional robotics systems designed to work with MRI, CT, fluoroscopy, and ultrasound imaging devices. The details of each system are given along with any phantom, animal, or human trials. The systems include the AcuBot for active needle insertion under CT or fluoroscopy, the B-Rob systems for needle placement using CT or ultrasound, the INNOMOTION for MRI and CT interventions, and the MRBot for MRI procedures. Following these descriptions, the technology issues of image compatibility, registration, patient movement and respiration, force feedback, and control mode are briefly discussed. It is our belief that robotic systems will be an important part of future interventions, but more research and clinical trials are needed. The possibility of performing new clinical procedures that the human cannot achieve remains an ultimate goal for medical robotics. Engineers and physicians should work together to create and validate these systems for the benefits of patients everywhere. PMID:16754193

  4. Accuracy Considerations in Image-guided Cardiac Interventions: Experience and Lessons Learned

    PubMed Central

    Linte, Cristian A.; Lang, Pencilla; Rettmann, Maryam E.; Cho, Daniel S.; Holmes, David R.; Robb, Richard A.; Peters, Terry M.

    2014-01-01

    Motivation Medical imaging and its application in interventional guidance has revolutionized the development of minimally invasive surgical procedures leading to reduced patient trauma, fewer risks, and shorter recovery times. However, a frequently posed question with regards to an image guidance system is “how accurate is it?” On one hand, the accuracy challenge can be posed in terms of the tolerable clinical error associated with the procedure; on the other hand, accuracy is bound by the limitations of the system’s components, including modeling, patient registration, and surgical instrument tracking, all of which ultimately impact the overall targeting capabilities of the system. Methods While these processes are not unique to any interventional specialty, this paper discusses them in the context of two different cardiac image-guidance platforms: a model-enhanced ultrasound platform for intracardiac interventions and a prototype system for advanced visualization in image-guided cardiac ablation therapy. Results Pre-operative modeling techniques involving manual, semi-automatic and registration-based segmentation are discussed. The performance and limitations of clinically feasible approaches for patient registration evaluated both in the laboratory and operating room are presented. Our experience with two different magnetic tracking systems for instrument and ultrasound transducer localization is reported. Ultimately, the overall accuracy of the systems is discussed based on both in vitro and preliminary in vivo experience. Conclusion While clinical accuracy is specific to a particular patient and procedure and vastly dependent on the surgeon’s experience, the system’s engineering limitations are critical to determine whether the clinical requirements can be met. PMID:21671097

  5. A multimodality imaging-compatible insertion robot with a respiratory motion calibration module designed for ablation of liver tumors: a preclinical study.

    PubMed

    Li, Dongrui; Cheng, Zhigang; Chen, Gang; Liu, Fangyi; Wu, Wenbo; Yu, Jie; Gu, Ying; Liu, Fengyong; Ren, Chao; Liang, Ping

    2018-04-03

    To test the accuracy and efficacy of the multimodality imaging-compatible insertion robot with a respiratory motion calibration module designed for ablation of liver tumors in phantom and animal models. To evaluate and compare the influences of intervention experience on robot-assisted and ultrasound-controlled ablation procedures. Accuracy tests on rigid body/phantom model with a respiratory movement simulation device and microwave ablation tests on porcine liver tumor/rabbit liver cancer were performed with the robot we designed or with the traditional ultrasound-guidance by physicians with or without intervention experience. In the accuracy tests performed by the physicians without intervention experience, the insertion accuracy and efficiency of robot-assisted group was higher than those of ultrasound-guided group with statistically significant differences. In the microwave ablation tests performed by the physicians without intervention experience, better complete ablation rate was achieved when applying the robot. In the microwave ablation tests performed by the physicians with intervention experience, there was no statistically significant difference of the insertion number and total ablation time between the robot-assisted group and the ultrasound-controlled group. The evaluation by the NASA-TLX suggested that the robot-assisted insertion and microwave ablation process performed by physicians with or without experience were more comfortable. The multimodality imaging-compatible insertion robot with a respiratory motion calibration module designed for ablation of liver tumors could increase the insertion accuracy and ablation efficacy, and minimize the influence of the physicians' experience. The ablation procedure could be more comfortable with less stress with the application of the robot.

  6. Ultrasound-Guided Percutaneous Tenotomy of Biceps Tendon: Technical Feasibility on Cadavers.

    PubMed

    Sconfienza, Luca Maria; Mauri, Giovanni; Messina, Carmelo; Aliprandi, Alberto; Secchi, Francesco; Sardanelli, Francesco; Randelli, Pietro Simone

    2016-10-01

    We tested the technical feasibility of ultrasound-guided percutaneous tenotomy of the long head of the biceps tendon (LHBT) in cadavers. Both shoulders of two fresh cadavers were scanned anteriorly to evaluate the extra-articular portion of the LHBT. Under ultrasound monitoring, a scalpel was advanced obliquely up to touch the superficial medial side of the LHBT, cutting it until the tendon was not visible anymore. Ultrasound evaluation was repeated after the procedure, and anatomic dissection was performed. The procedure was 100% feasible: four cuts were made to completely sever the tendon; the duration was less than 1 min. Skin incision measured 5 mm in two cases and 6 mm in two cases. Anatomic dissection confirmed complete tendon cut in all cases with proximal and distal tendon stumps very close to each other. Ultrasound-guided percutaneous LHBT tenotomy was 100% technically feasible in cadavers with a quick procedure and minimal cutaneous incision. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  7. White Paper: Interventional MRI: Current Status and Potential for Development Considering Economic Perspectives, Part 1: General Application.

    PubMed

    Barkhausen, Jörg; Kahn, Thomas; Krombach, Gabriele A; Kuhl, Christiane K; Lotz, Joachim; Maintz, David; Ricke, Jens; Schönberg, Stefan O; Vogl, Thomas J; Wacker, Frank K

    2017-07-01

    Background  MRI is attractive for the guiding and monitoring of interventional procedures due to its high intrinsic soft tissue contrast and the possibility to measure physiologic parameters like flow and cardiac function. Method  The current status of interventional MRI for the clinical routine was analyzed. Results  The effort needed for the development of MR-safe monitoring systems and instruments initially resulted in the application of interventional MRI only for procedures that could not be performed by other means. Accordingly, biopsy of lesions in the breast, which are not detectable by other modalities, has been performed under MRI guidance for decades. Currently, biopsies of the prostate under MRI guidance are established in a similar fashion. At many sites blind biopsy has already been replaced by MR-guided biopsy or at least by the fusion of MR images with ultrasound. Cardiovascular interventions are performed at several centers for ablation as a treatment for atrial fibrillation. Conclusion  Interventional MRI has been established in the clinical routine for a variety of indications. Broader application can be expected in the clinical routine in the future owing to the multiple advantages compared to other techniques. Key points   · Due to the significant technical effort, MR-guided interventions are only recommended in the long term for regions in which MRI either facilitates or greatly improves the intervention.. · Breast biopsy of otherwise undetectable target lesions has long been established in the clinical routine. Prostate biopsy is currently being introduced in the clinical routine for similar reasons. Other methods such as MR-guided focused ultrasound for the treatment of uterine fibroids or tumor ablation of metastases represent alternative methods and are offered in many places.. · Endovascular MR-guided interventions offer advantages for a number of indications and have already been clinically established for the treatment of children with congenital heart defects and for atrial ablation at individual centers. Greater application can be expected in the future.. Citation format · Barkhausen J, Kahn T, Krombach GA et al. White Paper: Interventional MRI: Current Status and Potential for Development Considering Economic Perspectives, Part 1: General Application. Fortschr Röntgenstr 2017; 189: 611 - 623. © Georg Thieme Verlag KG Stuttgart · New York.

  8. Comparison of Stereotactic and Ultrasound-guided Biopsy of Solid Supratentorial Tumor: A Preliminary Report

    PubMed Central

    Satyarthee, Guru Dutta; Chandra, P. Sarat; Sharma, Bhawani S.; Mehta, V. S.

    2017-01-01

    Introduction: The computed tomography (CT) guided stereotactic biopsy (STB) is considered as method of choice for biopsy of intracranial mass lesions. However, it's disadvantages are frame fixation, time requirement for transportation between CT scan suit to the operation theater with added much higher equipment cost in the relatively resource scarred developing country. Ultrasound-guided biopsy (USGB) is relatively simpler, economical, less time consuming, and real-time procedure. Clinical Materials and Methods: Thirty-seven consecutively admitted patients with supratentorial brain tumors, who underwent biopsy of the lesion using CT compatible stereotactic and ultrasound-guided (USGB) procedure formed cohort of the study. Based on location and size of the lesions, the cases were divided into two groups, superficial and deep. Twenty-two patients underwent ultrasound-guided biopsy and 15 with STB. Results: The diagnostic yield of STB was 93% and 91% for ultrasound-guided biopsy. The mean operation time of STB group was 149.00 min and 94 min for USGB, which was statistically significant. Two cases in each group developed hematoma; however, one case in USGB group needed surgical evacuation. The real-time monitoring detected two hematoma intraoperatively, which were further also confirmed on postoperative CT scan head. Conclusions: The ultrasound-guided biopsy procedure (USGB) was simple, relatively shorter time-consuming procedure and equally efficacious and utilizing economical equipment and can act as a safer alternative to CT STB process for biopsy of the intracranial mass lesion. Furthermore, USGB also provided intra-operative real-time monitoring, which provided clue for close monitoring in the postoperative period after completion of biopsy to look for development of fresh hematoma development not only at the biopsy site but also along the biopsy track and adjoining area. Perhaps, a longer period of ultrasonic monitoring following the procedure would be of greater help to detect hematoma formation, which is one of the most common complications of the biopsy procedure. PMID:29114280

  9. Ultrasonographic percutaneous anatomy of the atlanto-occipital region and indirect ultrasound-guided cisternal puncture in the dog and the cat.

    PubMed

    Etienne, A-L; Audigié, F; Peeters, D; Gabriel, A; Busoni, V

    2015-04-01

    Cisternal puncture in dogs and cats is commonly carried out. This article describes the percutaneous ultrasound anatomy of the cisternal region in the dog and the cat and an indirect technique for ultrasound-guided cisternal puncture. Ultrasound images obtained ex vivo and in vivo were compared with anatomic sections and used to identify the landmarks for ultrasound-guided cisternal puncture. The ultrasound-guided procedure was established in cadavers and then applied in vivo in seven dogs and two cats. The anatomic landmarks for the ultrasound-guided puncture are the cisterna magna, the spinal cord, the two occipital condyles on transverse images, the external occipital crest and the dorsal arch of the first cervical vertebra on longitudinal images. Using these ultrasound anatomic landmarks, an indirect ultrasound-guided technique for cisternal puncture is applicable in the dog and the cat. © 2014 Blackwell Verlag GmbH.

  10. Image Guidance Technologies for Interventional Pain Procedures: Ultrasound, Fluoroscopy, and CT.

    PubMed

    Wang, Dajie

    2018-01-26

    Chronic pain is a common medical condition. Patients who suffer uncontrolled chronic pain may require interventions including spinal injections and various nerve blocks. Interventional procedures have evolved and improved over time since epidural injection was first introduced for low back pain and sciatica in 1901. One of the major contributors in the improvement of these interventions is the advancement of imaging guidance technologies. The utilization of image guidance has dramatically improved the accuracy and safety of these interventions. The first image guidance technology adopted by pain specialists was fluoroscopy. This was followed by CT and ultrasound. Fluoroscopy can be used to visualize bony structures of the spine. It is still the most commonly used guidance technology in spinal injections. In the recent years, ultrasound guidance has been increasingly adopted by interventionists to perform various injections. Because its ability to visualize soft tissue, vessels, and nerves, this guidance technology appears to be a better option than fluoroscopy for interventions including SGB and celiac plexus blocks, when visualization of the vessels may prevent intravascular injection. The current evidence indicates the efficacies of these interventions are similar between ultrasound guidance and fluoroscopy guidance for SGB and celiac plexus blocks. For facet injections and interlaminar epidural steroid injections, it is important to visualize bony structures in order to perform these procedures accurately and safely. It is worth noting that facet joint injections can be done under ultrasound guidance with equivalent efficacy to fluoroscopic guidance. However, obese patients may present challenge for ultrasound guidance due to its poor visualization of deep anatomical structures. Regarding transforaminal epidural steroid injections, there are limited evidence to support that ultrasound guidance technology has equivalent efficacy and less complications comparing to fluoroscopy. However, further studies are required to prove the efficacy of ultrasound-guided transforaminal epidural injections. SI joint is unique due to its multiplanar orientation, irregular joint gap, partial ankylosis, and thick dorsal and interosseous ligament. Therefore, it can be difficult to access the joint space with fluoroscopic guidance and ultrasound guidance. CT scan, with its cross-sectional images, can identify posterior joint gap, is most likely the best guidance technology for this intervention. Intercostal nerves lie in the subcostal grove close to the plural space. Significant risk of pneumothorax is associated with intercostal blocks. Ultrasound can provide visualization of ribs and pleura. Therefore, it may improve the accuracy of the injection and reduce the risk of pneumothorax. At present time, most pain specialists are familiar with fluoroscopic guidance techniques, and fluoroscopic machines are readily available in the pain clinics. In the contrast, CT guidance can only be performed in specially equipped facilities. Ultrasound machine is generally portable and inexpensive in comparison to CT scanner and fluoroscopic machine. As pain specialists continue to improve their patient care, ultrasound and CT guidance will undoubtedly be incorporated more into the pain management practice. This review is based on a paucity of clinical evidence to compare these guidance technologies; clearly, more clinical studies is needed to further elucidate the pro and cons of each guidance method for various pain management interventions.

  11. Guided Interventions for Prostate Cancer Using 3D-Transurethral Ultrasound and MRI Fusion

    DTIC Science & Technology

    2017-06-01

    standard transrectal ultrasound (TRUS) probe, a TUUS probe, and MRI. (a) (b) Figure 2: 3D printed prostate phantom mold (a), and pelvis phantom mold...with prostate agar phantom in place (b). The TUUS phantoms were prepared using a standard recipe [ii] for the prostate and the 3D printed mold...AWARD NUMBER: W81XWH-14-1-0461 TITLE: Guided Interventions for Prostate Cancer Using 3D -Transurethral Ultrasound and MRI Fusion PRINCIPAL

  12. Ultrasound for the Anesthesiologists: Present and Future

    PubMed Central

    Terkawi, Abdullah S.; Karakitsos, Dimitrios; Elbarbary, Mahmoud; Blaivas, Michael; Durieux, Marcel E.

    2013-01-01

    Ultrasound is a safe, portable, relatively inexpensive, and easily accessible imaging modality, making it a useful diagnostic and monitoring tool in medicine. Anesthesiologists encounter a variety of emergent situations and may benefit from the application of such a rapid and accurate diagnostic tool in their routine practice. This paper reviews current and potential applications of ultrasound in anesthesiology in order to encourage anesthesiologists to learn and use this useful tool as an adjunct to physical examination. Ultrasound-guided peripheral nerve blockade and vascular access represent the most popular ultrasound applications in anesthesiology. Ultrasound has recently started to substitute for CT scans and fluoroscopy in many pain treatment procedures. Although the application of airway ultrasound is still limited, it has a promising future. Lung ultrasound is a well-established field in point-of-care medicine, and it could have a great impact if utilized in our ORs, as it may help in rapid and accurate diagnosis in many emergent situations. Optic nerve sheath diameter (ONSD) measurement and transcranial color coded duplex (TCCD) are relatively new neuroimaging modalities, which assess intracranial pressure and cerebral blood flow. Gastric ultrasound can be used for assessment of gastric content and diagnosis of full stomach. Focused transthoracic (TTE) and transesophageal (TEE) echocardiography facilitate the assessment of left and right ventricular function, cardiac valve abnormalities, and volume status as well as guiding cardiac resuscitation. Thus, there are multiple potential areas where ultrasound can play a significant role in guiding otherwise blind and invasive interventions, diagnosing critical conditions, and assessing for possible anatomic variations that may lead to plan modification. We suggest that ultrasound training should be part of any anesthesiology training program curriculum. PMID:24348179

  13. [Feasibility of device closure for multiple atrial septal defects using 3D printing and ultrasound-guided intervention technique].

    PubMed

    Qiu, X; Lü, B; Xu, N; Yan, C W; Ouyang, W B; Liu, Y; Zhang, F W; Yue, Z Q; Pang, K J; Pan, X B

    2017-04-25

    Objective: To investigate the feasibility of trans-catheter closure of multiple atrial septal defects (ASD) monitored by trans-thoracic echocardiography (TTE) under the guidance of 3D printing heart model. Methods: Between April and August 2016, a total of 21 patients (8 male and 13 female) with multiple ASD in Fuwai Hospital of Chinese Academy of Medical Sciences underwent CT scan and 3-dimensional echocardiography for heart disease model produced by 3D printing technique. The best occlusion program was determined through the simulation test on the model. Percutaneous device closure of multiple ASD was performed follow the predetermined program guided by TTE. Clinical follow-up including electrocardiogram and TTE was arranged at 1 month after the procedure. Results: The trans-catheter procedure was successful in all 21 patients using a single atrial septal occluder. Mild residual shunt was found in 5 patient in the immediate postoperative period, 3 of them were disappeared during postoperative follow-up. There was no death, vascular damage, arrhythmia, device migration, thromboembolism, valvular dysfunction during the follow-up period. Conclusion: The use of 3D printing heart model provides a useful reference for transcatheter device closure of multiple ASD achieving through ultrasound-guided intervention technique, which appears to be safe and feasible with good outcomes of short-term follow-up.

  14. The role of ultrasound guidance in pediatric caudal block

    PubMed Central

    Erbüyün, Koray; Açıkgöz, Barış; Ok, Gülay; Yılmaz, Ömer; Temeltaş, Gökhan; Tekin, İdil; Tok, Demet

    2016-01-01

    Objectives: To compare the time interval of the procedure, possible complications, post-operative pain levels, additional analgesics, and nurse satisfaction in ultrasonography-guided and standard caudal block applications. Methods: This retrospective study was conducted in Celal Bayar University Hospital, Manisa, Turkey, between January and December 2014, included 78 pediatric patients. Caudal block was applied to 2 different groups; one with ultrasound guide, and the other using the standard method. Results: The time interval of the procedure was significantly shorter in the standard application group compared with ultrasound-guided group (p=0.020). Wong-Baker FACES Pain Rating Scale values obtained at the 90th minute was statistically lower in the standard application group compared with ultrasound-guided group (p=0.035). No statistically significant difference was found on the other parameters between the 2 groups. The shorter time interval of the procedure at standard application group should not be considered as a distinctive mark by the pediatric anesthesiologists, because this time difference was as short as seconds. Conclusion: Ultrasound guidance for caudal block applications would neither increase nor decrease the success of the treatment. However, ultrasound guidance should be needed in cases where the detection of sacral anatomy is difficult, especially by palpations. PMID:26837396

  15. Septic bursitis after ultrasound-guided percutaneous treatment of rotator cuff calcific tendinopathy.

    PubMed

    Sconfienza, Luca Maria; Randelli, Filippo; Sdao, Silvana; Sardanelli, Francesco; Randelli, Pietro

    2014-08-01

    Calcific tendinopathy of the rotator cuff is a common condition. Ultrasound-guided percutaneous aspiration is one of several options to treat this condition. The main advantages of this procedure are short duration, good outcome, and low cost. Furthermore, only minor complications have been reported in the literature, namely, vagal reactions during the procedure and mild postprocedural pain. We report the first case of septic bursitis after ultrasound-guided percutaneous treatment of calcific tendinopathy. Although this is generally considered a very safe procedure, a risk of infection should be taken into account. Copyright © 2014 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  16. Delay and Standard Deviation Beamforming to Enhance Specular Reflections in Ultrasound Imaging.

    PubMed

    Bandaru, Raja Sekhar; Sornes, Anders Rasmus; Hermans, Jeroen; Samset, Eigil; D'hooge, Jan

    2016-12-01

    Although interventional devices, such as needles, guide wires, and catheters, are best visualized by X-ray, real-time volumetric echography could offer an attractive alternative as it avoids ionizing radiation; it provides good soft tissue contrast, and it is mobile and relatively cheap. Unfortunately, as echography is traditionally used to image soft tissue and blood flow, the appearance of interventional devices in conventional ultrasound images remains relatively poor, which is a major obstacle toward ultrasound-guided interventions. The objective of this paper was therefore to enhance the appearance of interventional devices in ultrasound images. Thereto, a modified ultrasound beamforming process using conventional-focused transmit beams is proposed that exploits the properties of received signals containing specular reflections (as arising from these devices). This new beamforming approach referred to as delay and standard deviation beamforming (DASD) was quantitatively tested using simulated as well as experimental data using a linear array transducer. Furthermore, the influence of different imaging settings (i.e., transmit focus, imaging depth, and scan angle) on the obtained image contrast was evaluated. The study showed that the image contrast of specular regions improved by 5-30 dB using DASD beamforming compared with traditional delay and sum (DAS) beamforming. The highest gain in contrast was observed when the interventional device was tilted away from being orthogonal to the transmit beam, which is a major limitation in standard DAS imaging. As such, the proposed beamforming methodology can offer an improved visualization of interventional devices in the ultrasound image with potential implications for ultrasound-guided interventions.

  17. Value of Artisanal Simulators to Train Veterinary Students in Performing Invasive Ultrasound-Guided Procedures

    ERIC Educational Resources Information Center

    Hage, Maria Cristina F. N. S.; Massaferro, Ana Beatriz; Lopes, Érika Rondon; Beraldo, Carolina Mariano; Daniel, Jéssika

    2016-01-01

    Pericardial effusion can lead to cardiac tamponade, which endangers an animal's life. Ultrasound-guided pericardiocentesis is used to remove abnormal liquid; however, it requires technical expertise. In veterinary medical education, the opportunity to teach this procedure to save lives during emergencies is rare; therefore, simulators are…

  18. Musculoskeletal ultrasound for interventional physiatry.

    PubMed

    De Muynck, M; Parlevliet, T; De Cock, K; Vanden Bossche, L; Vanderstraeten, G; Özçakar, L

    2012-12-01

    More and more physiatrists are interested in learning how to use musculoskeletal ultrasonography in their clinical practice. The possibility of high resolution, dynamic, comparative and repeatable imaging makes it an important diagnostic tool for soft tissue pathology. There is also growing interest to use sonography for guiding interventions such as aspirations and infiltrations. In daily practice these are often done blindly or palpation-guided. To improve the accuracy of interventions, fluoroscopy or computed tomography were traditionally used for guidance. Since sonography is non-ionizing, readily available and relatively low cost, it has become the first choice to guide many musculoskeletal interventions. Ultrasound allows real-time imaging of target and needle as well as surrounding vulnerable structures such as vessels and nerves. Many different techniques are proposed in the literature. Interventions under ultrasound guidance have been proven to be more accurate than unguided ones. Further studies are required to prove better clinical results and fewer complications. Infection is the most dreaded complication. This review wants to highlight technical aspects of ultrasound guidance of interventions and give a survey of different interventions that have been introduced, with emphasis on applications in Physical Medicine and Rehabilitation. Results and complications are discussed. Finally training requirements and modalities are presented.

  19. 'X-ray'-free balloon dilation for totally ultrasound-guided percutaneous nephrolithotomy.

    PubMed

    Zhou, Tie; Chen, Guanghua; Gao, Xiaofeng; Zhang, Wei; Xu, Chuanliang; Li, Lei; Sun, Yinghao

    2015-04-01

    The objective of the study was to evaluate the feasibility and safety of balloon dilation for 'X-ray'-free ultrasound-guided percutaneous nephrolithotomy (PCNL). From January 2012 to December 2012, patients underwent 'X-ray'-free ultrasound-guided PCNL with Amplatz dilator (Group A). From January 2013 to April 2014, patients underwent 'X-ray'-free ultrasound-guided PCNL with balloon dilator (Group B). For balloon dilation, a 10 F fascial dilator was used to dilate the tract. Subsequently, the 6 F nephrostomy balloon (8 mm in diameter) was indwelled along the guidewire with a marked length equal to the dilation depth. Under the monitoring of ultrasound, the location of balloon was secured and disappearance of balloon waist was confirmed when the balloon was inflated at a pressure of 20 atm. A total of 163 patients were involved in this study. Of 81 procedures in Group A, 45 procedures were performed by a senior urologist while 36 procedures by a resident. Of 82 patients in Group B, 47 procedures were performed by the same senior urologist while 35 procedures by another resident. For the senior urologist, there was no statistically significant difference between two groups in calyx of entry, stone-free rate, decline of hemoglobin and hematocrit, operation time and hospitalization. But for the residents, there was less decline of hemoglobin and hematocrit, tract development time and hospitalization in Group B compared to Group A (0.6 vs. 1.7 g/dl, p = 0.001; 2.3% vs. 5.5%, p = 0.003; 10.1 vs. 11.0 min, p = 0.027; 7.8 vs. 13.9 days, p < 0.001). Balloon dilation method introduced in this study is compensable for tract development when 'X-ray'-free ultrasound-guided PCNL is performed. Modified techniques make totally ultrasound guidance for PCNL feasible, easy and safe. In addition, such a procedure is preferable for initial operators because of less hemorrhage complication.

  20. Common Femoral Artery Access on YouTube: What Practices are Being Shown and Who is Delivering the Message?

    PubMed

    Pitcher, Grayson S; Newton, Daniel H; Amendola, Michael F

    Novice learners are increasingly turning to YouTube as a learning resource for surgical procedures. One example of such a procedure is common femoral artery puncture and sheath placement. Practitioners in several specialties perform this procedure to access the arterial system for angiography and intervention. We set forth to compare the techniques demonstrated on YouTube by the various specialists, as well as compare each specialty׳s prevalence on this website. YouTube (www.youtube.com) was accessed in December 2015 at multiple time points with a cleared-cache web browser for the keyword search categories: "femoral artery access," "femoral access," and "angiography access." The top 500 videos from each of these keyword searches were analyzed. Videos were categorized by practitioner specialty, technique, duration of video, age of video, and total views. Videos with clear demonstration of femoral artery access were included in the analysis. All industry videos were excluded from the analysis. Categorical variables were compared using Fisher׳s exact test, and continuous variables were compared with the Student׳s t-test. A total of 2460, 4680 and 1800 videos were found for each keyword search, respectively. Of these, 33 videos clearly demonstrated femoral artery access technique. Vascular specialists, compared to interventional cardiology and radiology, had fewer videos (n = 4 vs. 14) and older videos (3.5 ± 2.1y vs. 2.25 ± 0.5y, p < 0.05). The vascular specialists demonstrated ultrasound-guided access, while interventional cardiology predominantly demonstrated landmark-guided access (p < 0.05). Although YouTube and other online resources are being used by novice learners, vascular specialists are underrepresented for femoral artery access, a foundational vascular procedure. Other practitioners demonstrate videos with landmark-guided access and rarely demonstrate ultrasound use. As recognized vascular experts, vascular surgeons should improve their visibility in online learning resources. Copyright © 2017 Association of Program Directors in Surgery. All rights reserved.

  1. Ultrasound-guided thoracenthesis: the V-point as a site for optimal drainage positioning.

    PubMed

    Zanforlin, A; Gavelli, G; Oboldi, D; Galletti, S

    2013-01-01

    In the latest years the use of lung ultrasound is increasing in the evaluation of pleural effusions, because it makes follow-up easier and drainage more efficient by providing guidance on the most appropriate sampling site. However, no standardized approach for ultrasound-guided thoracenthesis is actually available. To evaluate our usual ultrasonographic landmark as a possible standard site to perform thoracenthesis by assessing its value in terms of safety and efficiency (success at first attempt, drainage as complete as possible). Hospitalized patients with non organized pleural effusion underwent thoracenthesis after ultrasound evaluation. The point showing on ultrasound the maximum thickness of the effusion ("V-point") was chosen for drainage. 45 ultrasound guided thoracenthesis were performed in 12 months. In 22 cases there were no complications; 16 cases of cough, 2 cases of mild dyspnea without desaturation, 4 cases of mild pain; 2 cases of complications requiring medical intervention occurred. No case of pneumothorax related to the procedure was detected. In all cases drainage was successful on the first attempt. The collected values of maximum thickness at V-point (min 3.4 cm - max 15.3 cm) and drained fluid volume (min 70 ml - max 2000 ml) showed a significative correlation (p < 0.0001). When the thickness was greater or equal to 9.9 cm, drained volume was always more than 1000 ml. The measure of the maximum thickness at V-point provides high efficiency to ultrasound guided thoracentesis and allows to estimate the amount of fluid in the pleural cavity. It is also an easy parameter that makes the proposed method quick to learn and apply.  

  2. Ultrasound-guided central venous access using Google Glass.

    PubMed

    Wu, Teresa S; Dameff, Christian J; Tully, Jeffrey L

    2014-12-01

    The use of ultrasound during invasive bedside procedures is quickly becoming the standard of care. Ultrasound machine placement during procedures often requires the practitioner to turn their head during the procedure to view the screen. Such turning has been implicated in unintentional hand movements in novices. Google Glass is a head-mounted computer with a specialized screen capable of projecting images and video into the view of the wearer. Such technology may help decrease unintentional hand movements. Our aim was to evaluate whether or not medical practitioners at various levels of training could use Google Glass to perform an ultrasound-guided procedure, and to explore potential advantages of this technology. Forty participants of varying training levels were randomized into two groups. One group used Google Glass to perform an ultrasound-guided central line. The other group used traditional ultrasound during the procedure. Video recordings of eye and hand movements were analyzed. All participants from both groups were able to complete the procedure without difficulty. Google Glass wearers took longer to perform the procedure at all training levels (medical student year 1 [MS1]: 193 s vs. 77 s, p > 0.5; MS4: 197s vs. 91s, p ≤ 0.05; postgraduate year 1 [PGY1]: 288s vs. 125 s, p > 0.5; PGY3: 151 s vs. 52 s, p ≤ 0.05), and required more needle redirections (MS1: 4.4 vs. 2.0, p > 0.5; MS4: 4.8 vs. 2.8, p > 0.5; PGY1: 4.4 vs. 2.8, p > 0.5; PGY3: 2.0 vs. 1.0, p > 0.5). In this study, it was possible to perform ultrasound-guided procedures with Google Glass. Google Glass wearers, on average, took longer to gain access, and had more needle redirections, but less head movements were noted. Copyright © 2014 Elsevier Inc. All rights reserved.

  3. Ultrasound-guided chest biopsies.

    PubMed

    Middleton, William D; Teefey, Sharlene A; Dahiya, Nirvikar

    2006-12-01

    Pulmonary nodules that are surrounded by aerated lung cannot be visualized with sonography. Therefore, percutaneous biopsy must be guided with computed tomography or fluoroscopy. Although this restriction only applies to central lung nodules, it has permeated referral patterns for other thoracic lesions and has retarded the growth of ultrasound-guided interventions. Nevertheless, sonography is an extremely flexible modality that can expeditiously guide many biopsy procedures in the thorax. Peripheral pulmonary nodules can be successfully biopsied with success rates exceeding 90% and complications rates of less than 5%. Orienting the probe parallel to the intercostal space facilitates biopsies of peripheral pulmonary nodules. Anterior mediastinal masses that extend to the parasternal region are often easily approachable provided the internal mammary vessels, costal cartilage, and deep great vessels are identified and avoided. Superior mediastinal masses can be sampled from a suprasternal or supraclavicular approach. Phased array probes or tightly curved arrays may provide improved access for biopsies in this location. Posterior mediastinal masses are more difficult to biopsy with ultrasound guidance because of the overlying paraspinal muscles. However, when posterior mediastinal masses extend into the posterior medial pleural region, they can be biopsied with ultrasound guidance. Because many lung cancers metastasize to the supraclavicular nodes, it is important to evaluate the supraclavicular region when determining the best approach to obtain a tissue diagnosis. When abnormal supraclavicular nodes are present, they often are the easiest and safest lesions to biopsy.

  4. Outcomes of percutaneous coronary intervention in intermediate coronary artery disease: fractional flow reserve-guided versus intravascular ultrasound-guided.

    PubMed

    Nam, Chang-Wook; Yoon, Hyuck-Jun; Cho, Yun-Kyeong; Park, Hyoung-Seob; Kim, Hyungseop; Hur, Seung-Ho; Kim, Yoon-Nyun; Chung, In-Sung; Koo, Bon-Kwon; Tahk, Seung-Jae; Fearon, William F; Kim, Kwon-Bae

    2010-08-01

    This study sought to evaluate the long-term clinical outcomes of a fractional flow reserve (FFR)-guided percutaneous coronary intervention (PCI) strategy compared with intravascular ultrasound (IVUS)-guided PCI for intermediate coronary lesions. Both FFR- and IVUS-guided PCI strategies have been reported to be safe and effective in intermediate coronary lesions. The study included 167 consecutive patients, with intermediate coronary lesions evaluated by FFR or IVUS (FFR-guided, 83 lesions vs. IVUS-guided, 94 lesions). Cutoff value of FFR in FFR-guided PCI was 0.80, whereas that for minimal lumen cross sectional area in IVUS-guided PCI was 4.0 mm(2). The primary outcome was defined as a composite of major adverse cardiac events including death, myocardial infarction, and ischemia-driven target vessel revascularization at 1 year after the index procedure. Baseline percent diameter stenosis and lesion length were similar in both groups (51 +/- 8% and 24 +/- 12 mm in the FFR group vs. 52 +/- 8% and 24 +/- 13 mm in the IVUS group, respectively). However, the IVUS-guided group underwent revascularization therapy significantly more often (91.5% vs. 33.7%, p < 0.001). No significant difference was found in major adverse cardiac event rates between the 2 groups (3.6% in FFR-guided PCI vs. 3.2% in IVUS-guided PCI). Independent predictors for performing intervention were guiding device: FFR versus IVUS (relative risk [RR]: 0.02); left anterior descending coronary artery versus non-left anterior descending coronary artery disease (RR: 5.60); and multi- versus single-vessel disease (RR: 3.28). Both FFR- and IVUS-guided PCI strategy for intermediate coronary artery disease were associated with favorable outcomes. The FFR-guided PCI reduces the need for revascularization of many of these lesions. Copyright (c) 2010 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  5. A non-disruptive technology for robust 3D tool tracking for ultrasound-guided interventions.

    PubMed

    Mung, Jay; Vignon, Francois; Jain, Ameet

    2011-01-01

    In the past decade ultrasound (US) has become the preferred modality for a number of interventional procedures, offering excellent soft tissue visualization. The main limitation however is limited visualization of surgical tools. A new method is proposed for robust 3D tracking and US image enhancement of surgical tools under US guidance. Small US sensors are mounted on existing surgical tools. As the imager emits acoustic energy, the electrical signal from the sensor is analyzed to reconstruct its 3D coordinates. These coordinates can then be used for 3D surgical navigation, similar to current day tracking systems. A system with real-time 3D tool tracking and image enhancement was implemented on a commercial ultrasound scanner and 3D probe. Extensive water tank experiments with a tracked 0.2mm sensor show robust performance in a wide range of imaging conditions and tool position/orientations. The 3D tracking accuracy was 0.36 +/- 0.16mm throughout the imaging volume of 55 degrees x 27 degrees x 150mm. Additionally, the tool was successfully tracked inside a beating heart phantom. This paper proposes an image enhancement and tool tracking technology with sub-mm accuracy for US-guided interventions. The technology is non-disruptive, both in terms of existing clinical workflow and commercial considerations, showing promise for large scale clinical impact.

  6. A successful model to learn and implement ultrasound-guided venous catheterization in apheresis.

    PubMed

    Gopalasingam, Nigopan; Thomsen, Anna-Marie Eller; Folkersen, Lars; Juhl-Olsen, Peter; Sloth, Erik

    2017-12-01

    Apheresis treatments can be performed with peripheral venous catheters (PVC), although central venous catheters (CVC) are inserted when PVCs fail or patient with history of difficult vascular access prior to the apheresis. Ultrasound guidance for PVC has shown promising results in other settings. To investigate if ultrasound guidance for PVC could be implemented among apheresis nurses. Second, how implementation of ultrasound guidance affected the number of CVCs used for apheresis per patient. Apheresis nurses completed a systematic training program for ultrasound-guided vascular access. All independent catheterizations were registered during the implementation stage. The number of CVCs in the pre- and postimplementation stages of the ultrasound guidance was compared. Six nurses completed the training program within a median of 48 days (range 38-83 days). In 77 patients, 485 independent ultrasound-guided PVC placements were performed during the implementation stage. All apheresis treatments (485/485) were accomplished using PVCs without requiring CVC as rescue. During the preimplementation stage, 125 of 273 (45.8%) procedures required a CVC for completion of apheresis procedures; during the postimplementation stage only 30 of 227 (13.2%) procedures required a CVC (p < 0.001). In the postimplementation stage, no CVCs were placed as rescue caused by failed PVCs but were only placed for patients where the ultrasound machine was unavailable. It indicates an effective success rate of 100% for ultrasound-guided PVC use. This study showed that ultrasound guidance could be implemented among apheresis nurses as a routine tool eliminating the need of CVC as a rescue. © 2017 Wiley Periodicals, Inc.

  7. Comparison of clinical marking and ultrasound-guided injection of Botulinum type A toxin into the masseter muscles for treating bruxism and its cosmetic effects.

    PubMed

    Quezada-Gaon, Natacha; Wortsman, Ximena; Peñaloza, Osvaldo; Carrasco, Juan Eduardo

    2016-09-01

    Botulinum toxin type A has been used for treating the hypertrophy of the masseter muscles and its cosmetic effects. Ultrasound is increasingly used in dermatology, along with the guidance of mini-invasive procedures. To evaluate the role of ultrasound for guiding the application of Botulinum A toxin in patients with cosmetic alterations due to bruxism, correlate the clinical landmarks with the ultrasound findings, and study the effect on the symptoms, cosmetics, and quality of life. Twenty individuals with bruxism and cosmetic alterations underwent an ultrasound-guided injection of Botulinum toxin type A in each masseter muscle. Clinical and ultrasound marking of the procedure was compared. Clinical and sonographic evaluation was performed at the time of injection and 3 months later. Ten normal individuals underwent ultrasound of the masseter muscles as a control group. Up to 65% of individuals showed anatomical variants of the salivary glands. The method for clinically marking the skin showed a frequently erroneous location of the anterior point (up to 40% of cases) that was proven by ultrasound to be out of the muscle. In 20% of cases, ultrasound showed that the needle should be longer to enter the muscle. After injection, most of the patients demonstrated a decrease of the symptoms and cosmetic and quality of life improvements. Ultrasound can be a potent tool for guiding the injection of Botulinum toxin into the masseter muscles. It may contribute to a more personalized procedure, better cosmetic results, and help to avoid potential complications. © 2016 Wiley Periodicals, Inc.

  8. Multispectral photoacoustic imaging of nerves with a clinical ultrasound system

    NASA Astrophysics Data System (ADS)

    Mari, Jean Martial; West, Simeon; Beard, Paul C.; Desjardins, Adrien E.

    2014-03-01

    Accurate and efficient identification of nerves is of great importance during many ultrasound-guided clinical procedures, including nerve blocks and prostate biopsies. It can be challenging to visualise nerves with conventional ultrasound imaging, however. One of the challenges is that nerves can have very similar appearances to nearby structures such as tendons. Several recent studies have highlighted the potential of near-infrared optical spectroscopy for differentiating nerves and adjacent tissues, as this modality can be sensitive to optical absorption of lipids that are present in intra- and extra-neural adipose tissue and in the myelin sheaths. These studies were limited to point measurements, however. In this pilot study, a custom photoacoustic system with a clinical ultrasound imaging probe was used to acquire multi-spectral photoacoustic images of nerves and tendons from swine ex vivo, across the wavelength range of 1100 to 1300 nm. Photoacoustic images were processed and overlaid in colour onto co-registered conventional ultrasound images that were acquired with the same imaging probe. A pronounced optical absorption peak centred at 1210 nm was observed in the photoacoustic signals obtained from nerves, and it was absent in those obtained from tendons. This absorption peak, which is consistent with the presence of lipids, provides a novel image contrast mechanism to significantly enhance the visualization of nerves. In particular, image contrast for nerves was up to 5.5 times greater with photoacoustic imaging (0.82 +/- 0.15) than with conventional ultrasound imaging (0.148 +/- 0.002), with a maximum contrast of 0.95 +/- 0.02 obtained in photoacoustic mode. This pilot study demonstrates the potential of photoacoustic imaging to improve clinical outcomes in ultrasound-guided interventions in regional anaesthesia and interventional oncology.

  9. Endoscopic ultrasound-guided choledochoduodenostomy after a failed or impossible ERCP.

    PubMed

    Mora Soler, Ana María; Álvarez Delgado, Alberto; Piñero Pérez, María Concepción; Velasco-Guardado, Antonio; Marcos Prieto, Héctor; Rodríguez Pérez, Antonio

    2018-05-01

    endoscopic ultrasound-guided biliary drainage (EUS-BD) is an alternative to percutaneous trans-hepatic biliary drainage (PTBD) in cases of failed endoscopic retrograde cholangiopancreatography (ERCP). this is a retrospective description of six cases of endoscopic ultrasound-guided biliary drainage via choledochoduodenostomy (EUCD), as well as the clinical characteristics, endoscopic procedure, complications and monitoring. all cases had malignant distal biliary obstruction. The procedure was concluded with good drainage in four out of six patients. Two late complications were recorded that were caused by stent migration and there were no deaths related with the procedure. The average monitoring period was six months. EUCD can be considered as a valid therapeutic choice in some selected cases and when performed by a team of expert endoscopists in cases of failed ERCP drainage or as an alternative to PTBD. However, the procedure has some associated complications.

  10. Evaluation of the eZono 4000 with eZGuide for ultrasound-guided procedures.

    PubMed

    Gadsden, Jeff; Latmore, Malikah; Levine, Daniel M

    2015-05-01

    Ultrasound-guided procedures are increasingly common in a variety of acute care settings, such as the operating room, critical care unit and emergency room. However, accurate judgment of needle tip position using traditional ultrasound technology is frequently difficult, and serious injury can result from inadvertently advancing beyond or through the target. Needle navigation is a recent innovation that allows the clinician to visualize the needle position and trajectory in real time as it approaches the target. A novel ultrasound machine has recently been introduced that is portable and designed for procedural guidance. The eZono 4000™ features an innovative needle navigation technology that is simple to use and permits the use of a wide range of commercially available needles, avoiding the inconvenience and cost of proprietary equipment. This article discusses this new ultrasound machine in the context of other currently available ultrasound machines featuring needle navigation.

  11. An inexpensive, easily constructed, reusable task trainer for simulating ultrasound-guided pericardiocentesis.

    PubMed

    Zerth, Herb; Harwood, Robert; Tommaso, Laura; Girzadas, Daniel V

    2012-12-01

    Pericardiocentesis is a low-frequency, high-risk procedure integral to the practice of emergency medicine. Ultrasound-guided pericardiocentesis is the preferred technique for providing this critical intervention. Traditionally, emergency physicians learned pericardiocentesis in real time, at the bedside, on critically ill patients. Medical education is moving toward simulation for training and assessment of procedures such as pericardiocentesis because it allows learners to practice time-sensitive skills without risk to patient or learner. The retail market for models for pericardiocentesis practice is limited and expensive. We have developed an ultrasound-guided pericardiocentesis task trainer that allows the physician to insert a needle under ultrasound guidance, pierce the "pericardial sac" and aspirate "blood." Our model can be simply constructed in a home kitchen, and the overall preparation time is 1 h. Our model costs $20.00 (US, 2008). Materials needed for the construction include 16 ounces of plain gelatin, one large balloon, one golf ball, food coloring, non-stick cooking spray, one wooden cooking skewer, surgical iodine solution, and a 4-quart sized plastic food storage container. Refrigeration and a heat source for cooking are also required. Once prepared, the model is usable for 2 weeks at room temperature and may be preserved an additional week if refrigerated. When the model shows signs of wear, it can be easily remade, by simply recycling the existing materials. The self-made model was well liked by training staff due to accessibility of a simulation model, and by learners of the technique as they felt more at ease performing pericardiocentesis on a live patient. Copyright © 2012 Elsevier Inc. All rights reserved.

  12. Ultrasound guided reduction of an ileocolic intussusception by a hydrostatic method by using normal saline enema in paediatric patients: a study of 30 cases.

    PubMed

    Digant, Shastri Mona; Rucha, Seth; Eke, Dessai

    2012-12-01

    The conventional hydrostatic reduction of an intussusception with barium enema or the pneumatic reduction of an intussusception is associated with considerable ionizing radiations and a risk of perforation; while the hydrostatic reduction of an intussusception under ultrasound guidance is a very safe method because the whole procedure is visualized with real time ultrasound. Also, being a non-invasive method with a high success rate, this procedure has emerged as a useful alternative to a surgical intervention. The aim of this study was to evaluate the role of ultrasound and colour Doppler studies for the guidance of the hydrostatic reduction of a childhood intussusception by using normal saline. Among 41 children who were evaluated with ultrasonography for the confirmation of the presence of intussusceptions, hydrostatic reduction of intussusception were performed under a sonographic guidance in 30 patients, whereas 11 patients were excluded due to clinical contraindications. This disease was observed mostly at the ages of 6 months to 24 months. In 80% of the patients, there was a recent history of gastroenteritis and 40 % had a history of common cold. The most common site of the intussusception was the transverse colon near the hepatic flexor of the colon (90%), with a mean duration of 22.1±17.3 hours. The overall rate of a successful reduction was 87% and the mean reduction time was 14 minutes. None of the cases showed recurrence within 24 hrs. No complications were observed. We conclude that ultrasound with colour Doppler study is very useful for the diagnosis of intussusceptions, as well as for guided hydrostatic reductions by using normal saline enema. This is an optimal, simple, and a safe procedure for the treatment of intussusceptions in paediatric patients.

  13. Virtual reality, ultrasound-guided liver biopsy simulator: development and performance discrimination.

    PubMed

    Johnson, S J; Hunt, C M; Woolnough, H M; Crawshaw, M; Kilkenny, C; Gould, D A; England, A; Sinha, A; Villard, P F

    2012-05-01

    The aim of this article was to identify and prospectively investigate simulated ultrasound-guided targeted liver biopsy performance metrics as differentiators between levels of expertise in interventional radiology. Task analysis produced detailed procedural step documentation allowing identification of critical procedure steps and performance metrics for use in a virtual reality ultrasound-guided targeted liver biopsy procedure. Consultant (n=14; male=11, female=3) and trainee (n=26; male=19, female=7) scores on the performance metrics were compared. Ethical approval was granted by the Liverpool Research Ethics Committee (UK). Independent t-tests and analysis of variance (ANOVA) investigated differences between groups. Independent t-tests revealed significant differences between trainees and consultants on three performance metrics: targeting, p=0.018, t=-2.487 (-2.040 to -0.207); probe usage time, p = 0.040, t=2.132 (11.064 to 427.983); mean needle length in beam, p=0.029, t=-2.272 (-0.028 to -0.002). ANOVA reported significant differences across years of experience (0-1, 1-2, 3+ years) on seven performance metrics: no-go area touched, p=0.012; targeting, p=0.025; length of session, p=0.024; probe usage time, p=0.025; total needle distance moved, p=0.038; number of skin contacts, p<0.001; total time in no-go area, p=0.008. More experienced participants consistently received better performance scores on all 19 performance metrics. It is possible to measure and monitor performance using simulation, with performance metrics providing feedback on skill level and differentiating levels of expertise. However, a transfer of training study is required.

  14. Interventional Cardiology: What's New?

    PubMed

    Scansen, Brian A

    2017-09-01

    Interventional cardiology in veterinary medicine continues to expand beyond the standard 3 procedures of patent ductus arteriosus occlusion, balloon pulmonary valvuloplasty, and transvenous pacing. Opportunities for fellowship training; advances in equipment, including high-resolution digital fluoroscopy, real-time 3-dimensional transesophageal echocardiography, fusion imaging, and rotational angiography; ultrasound-guided access and vascular closure devices; and refinement of techniques, including cutting and high-pressure ballooning, intracardiac and intravascular stent implantation, septal defect occlusion, transcatheter valve implantation, and hybrid approaches, are likely to transform the field over the next decade. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Pocket ultrasound device as a complement to physical examination for ascites evaluation and guided paracentesis.

    PubMed

    Keil-Ríos, Daniel; Terrazas-Solís, Hiram; González-Garay, Alejandro; Sánchez-Ávila, Juan Francisco; García-Juárez, Ignacio

    2016-04-01

    The pocket ultrasound device (PUD) is a new tool that may be of use in the early detection of ascites. Abdominal ultrasound-guided paracentesis has been reported to decrease the rate of complications due to the procedure, but must be performed in a healthcare setting; this new tool may be a useful on an ambulatory basis. The aim of this study was to determine the diagnostic usefulness of the PUD in the diagnosis of ascites and the safety of guided paracentesis. We conducted a retrospective study that included adult patients suspected of having ascites and in whom an evaluation was performed with the PUD to identify it. Concordance with abdominal ultrasound (AUS) was determined with the Kappa coefficient. Sensitivity (Se), specificity (Sp) and likelihood ratios (LR) were determined and compared with physical examination, AUS, computed tomography and procurement of fluid by paracentesis. Complications resulting from the guided paracentesis were analyzed. 89 participants were included and 40 underwent a paracentesis. The PUD for ascites detection had 95.8 % Se, 81.8 % Sp, 5.27 +LR and 0.05 -LR. It had a concordance with AUS of 0.781 (p < 0.001). Technical problems during the guided paracentesis were present in only two participants (5 %) and three patients (7.5 %) developed minor complications that required no further intervention. There were no severe complications or deaths. This study suggests that the PUD is a reliable tool for ascites detection as a complement to physical examination and appears to be a safe method to perform guided paracentesis.

  16. Point-of-Care Ultrasonography Findings and Care Use Among Patients Undergoing Ultrasound-Guided Shoulder Injections.

    PubMed

    Lee, Se Won; Tiu, Timothy; Roberts, Jeremy; Lee, Brian; Bartels, Matthew N; Oh-Park, Mooyeon

    2018-01-01

    The aims of the study were to assess the overall reduction of pain in patients undergoing ultrasound-guided shoulder injections and to characterize the preinjection point-of-care ultrasound findings and use of clinical services postinjection including the use of magnetic resonance imaging and surgeries. Data of 172 patients who underwent ultrasound-guided subacromial subdeltoid injection or glenohumeral joint injection were reviewed for preinjection point-of-care ultrasound findings, change in pain intensity at 2 mos from baseline, and use of care at 6 mos' postinjection. Pain intensity was measured by the numeric rating scale and a dichotomous report of global impression of significant improvement in pain. Responders were defined as those with 50% or more reduction in numeric rating scale or those with global impression of 50% or more improvement. There were 141 responders among the 172 patients analyzed. Full-thickness rotator cuff tears were higher in the ultrasound-guided subacromial subdeltoid injection group when compared with the glenohumeral joint injection group (P = 0.038) and abnormal bicipital tendon findings higher in the glenohumeral joint injection group (P = 0.016). There were no significant differences in specific abnormal U findings between responders versus nonresponders. Twelve patients had a shoulder magnetic resonance imaging and four patients underwent operative interventions after the injection. Overall pain reduction after ultrasound-guided shoulder injections was favorable in the short term. There was no specific preinjection point-of-care ultrasound findings associated with clinical pain reduction after injection. Additional imaging and operative intervention after ultrasound-guided shoulder injections seemed to be relatively low.

  17. Fiber optic photoacoustic probe with ultrasonic tracking for guiding minimally invasive procedures

    NASA Astrophysics Data System (ADS)

    Xia, Wenfeng; Mosse, Charles A.; Colchester, Richard J.; Mari, Jean Martial; Nikitichev, Daniil I.; West, Simeon J.; Ourselin, Sebastien; Beard, Paul C.; Desjardins, Adrien E.

    2015-07-01

    In a wide range of clinical procedures, accurate placement of medical devices such as needles and catheters is critical to optimize patient outcomes. Ultrasound imaging is often used to guide minimally invasive procedures, as it can provide real-time visualization of patient anatomy and medical devices. However, this modality can provide low image contrast for soft tissues, and poor visualization of medical devices that are steeply angled with respect to the incoming ultrasound beams. Photoacoustic sensors can provide information about the spatial distributions of tissue chromophores that could be valuable for guiding minimally invasive procedures. In this study, a system for guiding minimally invasive procedures using photoacoustic sensing was developed. This system included a miniature photoacoustic probe with three optical fibers: one with a bare end for photoacoustic excitation of tissue, a second for photoacoustic excitation of an optically absorbing coating at the distal end to transmit ultrasound, and a third with a Fabry-Perot cavity at the distal end for receiving ultrasound. The position of the photoacoustic probe was determined with ultrasonic tracking, which involved transmitting pulses from a linear-array ultrasound imaging probe at the tissue surface, and receiving them with the fiber-optic ultrasound receiver in the photoacoustic probe. The axial resolution of photoacoustic sensing was better than 70 μm, and the tracking accuracy was better than 1 mm in both axial and lateral dimensions. By translating the photoacoustic probe, depth scans were obtained from different spatial positions, and two-dimensional images were reconstructed using a frequency-domain algorithm.

  18. Human placental vasculature imaging using an LED-based photoacoustic/ultrasound imaging system

    NASA Astrophysics Data System (ADS)

    Maneas, Efthymios; Xia, Wenfeng; Kuniyil Ajith Singh, Mithun; Sato, Naoto; Agano, Toshitaka; Ourselin, Sebastien; West, Simeon J.; David, Anna L.; Vercauteren, Tom; Desjardins, Adrien E.

    2018-02-01

    Minimally invasive fetal interventions, such as those used for therapy of twin-to-twin transfusion syndrome (TTTS), require accurate image guidance to optimise patient outcomes. Currently, TTTS can be treated fetoscopically by identifying anastomosing vessels on the chorionic (fetal) placental surface, and then performing photocoagulation. Incomplete photocoagulation increases the risk of procedure failure. Photoacoustic imaging can provide contrast for both haemoglobin concentration and oxygenation, and in this study, it was hypothesised that it can resolve chorionic placental vessels. We imaged a term human placenta that was collected after caesarean section delivery using a photoacoustic/ultrasound system (AcousticX) that included light emitting diode (LED) arrays for excitation light and a linear-array ultrasound imaging probe. Two-dimensional (2D) co-registered photoacoustic and B-mode pulse-echo ultrasound images were acquired and displayed in real-time. Translation of the imaging probe enabled 3D imaging. This feasibility study demonstrated that photoacoustic imaging can be used to visualise chorionic placental vasculature, and that it has strong potential to guide minimally invasive fetal interventions.

  19. Anaesthetics, steroids and platelet-rich plasma (PRP) in ultrasound-guided musculoskeletal procedures

    PubMed Central

    La Marra, Alice; Arrigoni, Francesco; Mariani, Silvia; Zugaro, Luigi; Splendiani, Alessandra; Di Cesare, Ernesto; Reginelli, Alfonso; Zappia, Marcello; Brunese, Luca; Duka, Ejona; Carrafiello, Giampaolo; Masciocchi, Carlo

    2016-01-01

    This review aims to evaluate the role of anaesthetics, steroids and platelet-rich plasma (PRP) employed with ultrasound-guided injection in the management of musculoskeletal pathology of the extremities. Ultrasound-guided injection represents an interesting and minimally invasive solution for the treatment of tendon and joint inflammatory or degenerative diseases. The availability of a variety of new drugs such as hyaluronic acid and PRP provides expansion of the indications and therapeutic possibilities. The clinical results obtained in terms of pain reduction and functional recovery suggest that the use of infiltrative procedures can be a good therapeutic alternative in degenerative and inflammatory joint diseases. PMID:27302491

  20. Anaesthetics, steroids and platelet-rich plasma (PRP) in ultrasound-guided musculoskeletal procedures.

    PubMed

    Barile, Antonio; La Marra, Alice; Arrigoni, Francesco; Mariani, Silvia; Zugaro, Luigi; Splendiani, Alessandra; Di Cesare, Ernesto; Reginelli, Alfonso; Zappia, Marcello; Brunese, Luca; Duka, Ejona; Carrafiello, Giampaolo; Masciocchi, Carlo

    2016-09-01

    This review aims to evaluate the role of anaesthetics, steroids and platelet-rich plasma (PRP) employed with ultrasound-guided injection in the management of musculoskeletal pathology of the extremities. Ultrasound-guided injection represents an interesting and minimally invasive solution for the treatment of tendon and joint inflammatory or degenerative diseases. The availability of a variety of new drugs such as hyaluronic acid and PRP provides expansion of the indications and therapeutic possibilities. The clinical results obtained in terms of pain reduction and functional recovery suggest that the use of infiltrative procedures can be a good therapeutic alternative in degenerative and inflammatory joint diseases.

  1. Ultrasound-guided percutaneous fine-needle aspiration of 545 focal pancreatic lesions.

    PubMed

    Zamboni, Giulia A; D'Onofrio, Mirko; Idili, Antonio; Malagò, Roberto; Iozzia, Roberta; Manfrin, Erminia; Mucelli, Roberto Pozzi

    2009-12-01

    The purpose of this study was to assess the accuracy and short-term complication rate of ultrasound-guided fine-needle aspiration cytologic sampling of focal pancreatic lesions. We reviewed 545 consecutive ultrasound-guided fine-needle aspiration cytologic sampling procedures for focal pancreatic lesions from January 2004 through June 2008. The procedures were performed with a 20- or 21-gauge needle. The onsite cytopathologist evaluated the appropriateness of the sample and made a diagnosis. We reviewed the final diagnosis and the radiologic and medical records of all patients for onset of complications during or within 7 days of the procedure. The study sample included 262 women and 283 men (mean age, 62 years; range, 25-86 years). The head or uncinate process of the pancreas was the location of 63.0% of the lesions, and 35.2% of the lesions were located in the body or tail of the pancreas. The site of 10 lesions (1.8%) was not specified. Sampling was diagnostic in 509 of the 545 cases (93.4%). Excluding the 36 nondiagnostic samples, ultrasound-guided fine-needle aspiration cytologic sampling had 99.4% sensitivity, 100% specificity, and 99.4% accuracy. In 537 of the 545 cases (98.5%), the procedure was uneventful. In two cases, abdominal fluid was found after the procedure that was not present before the procedure. Six patients experienced postprocedural pain without abnormal findings at subsequent imaging. No major complications occurred. Ultrasound-guided cytologic sampling is safe and accurate for the diagnosis and planning of management of focal pancreatic lesions. With a cytologist on site, the rate of acquisition of samples adequate for diagnosis is high, reducing the need for patient recall.

  2. Ergonomic task analysis of ultrasound-guided femoral nerve block: a pilot study.

    PubMed

    Ajmal, Muhammad; Power, Susan; Smith, Tim; Shorten, George D

    2011-02-01

    To apply ergonomic task analysis to the performance of ultrasound-guided (US-guided) femoral nerve block (FNB) in an acute hospital setting. Pilot prospective observational study. Orthopedic operating room of a regional trauma hospital. 15 anesthesiologists of various levels of experience in US-guided FNB (estimated minimum experience < 10 procedures; maximum about 50 procedures, and from basic trainees to consultants); and 15 patients (5 men and 10 women), aged 77 ± 15 (mean ± SD yrs) years. MEASUREMENTS/OBSERVATIONS: A data capture "tool", which was modified from one previously developed for ergonomic study of spinal anesthesia, was studied. Patient, operator, and heterogeneous environmental factors related to ergonomic performance of US-guided FNB were identified. The observation period started immediately before commencement of positioning the patient and ended on completion of perineural injection. Data were acquired using direct observations, photography, and application of a questionnaire. The quality of ergonomic performance was generally suboptimal and varied greatly among operators. Eight (experience < 10 procedures) of 15 operators excessively rotated their head, neck, and/or back to visualize the image on the ultrasound machine. Eight operators (experience < 10 procedures) performed the procedure with excessive thoracolumbar flexion. Performance of US-guided FNB presents ergonomic challenges and was suboptimal during most of the procedures observed. Formal training in US-guided peripheral nerve blockade should include reference to ergonomic factors. Copyright © 2011 Elsevier Inc. All rights reserved.

  3. Ultrasound-Guided Renal Access for Percutaneous Nephrolithotomy: A Description of Three Novel Ultrasound-Guided Needle Techniques

    PubMed Central

    Chu, Carissa; Masic, Selma; Usawachintachit, Manint; Hu, Weiguo; Yang, Wenzeng; Stoller, Marshall; Li, Jianxing

    2016-01-01

    Abstract Ultrasound-guided renal access for percutaneous nephrolithotomy (PCNL) is a safe, effective, and low-cost procedure commonly performed worldwide, but a technique underutilized by urologists in the United States. The purpose of this article is to familiarize the practicing urologist with methods for ultrasound guidance for percutaneous renal access. We discuss two alternative techniques for gaining renal access for PCNL under ultrasound guidance. We also describe a novel technique of using the puncture needle to reposition residual stone fragments to avoid additional tract dilation. With appropriate training, ultrasound-guided renal access for PCNL can lead to reduced radiation exposure, accurate renal access, and excellent stone-free success rates and clinical outcomes. PMID:26414304

  4. Comparison of Ultrasound-Guided and Fluoroscopy-Assisted Antegrade Common Femoral Artery Puncture Techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Slattery, Michael M.; Goh, Gerard S.; Power, Sarah

    PurposeTo prospectively compare the procedural time and complication rates of ultrasound-guided and fluoroscopy-assisted antegrade common femoral artery (CFA) puncture techniques.Materials and MethodsHundred consecutive patients, undergoing a vascular procedure for which an antegrade approach was deemed necessary/desirable, were randomly assigned to undergo either ultrasound-guided or fluoroscopy-assisted CFA puncture. Time taken from administration of local anaesthetic to vascular sheath insertion in the superficial femoral artery (SFA), patients’ age, body mass index (BMI), fluoroscopy radiation dose, haemostasis method and immediate complications were recorded. Mean and median values were calculated and statistically analysed with unpaired t tests.ResultsSixty-nine male and 31 female patients underwent antegrademore » puncture (mean age 66.7 years). The mean BMI was 25.7 for the ultrasound-guided (n = 53) and 25.3 for the fluoroscopy-assisted (n = 47) groups. The mean time taken for the ultrasound-guided puncture was 7 min 46 s and for the fluoroscopy-assisted technique was 9 min 41 s (p = 0.021). Mean fluoroscopy dose area product in the fluoroscopy group was 199 cGy cm{sup 2}. Complications included two groin haematomas in the ultrasound-guided group and two retroperitoneal haematomas and one direct SFA puncture in the fluoroscopy-assisted group.ConclusionUltrasound-guided technique is faster and safer for antegrade CFA puncture when compared to the fluoroscopic-assisted technique alone.« less

  5. Characterization of optically actuated MRI-compatible active needles for medical interventions

    NASA Astrophysics Data System (ADS)

    Black, Richard J.; Ryu, Seokchang; Moslehi, Behzad; Costa, Joannes M.

    2014-03-01

    The development of a Magnetic Resonance Imaging (MRI) compatible optically-actuated active needle for guided percutaneous surgery and biopsy procedures is described. Electrically passive MRI-compatible actuation in the small diameter needle is provided by non-magnetic materials including a shape memory alloy (SMA) subject to precise fiber laser operation that can be from a remote (e.g., MRI control room) location. Characterization and optimization of the needle is facilitated using optical fiber Bragg grating (FBG) temperature sensors arrays. Active bending of the needle during insertion allows the needle to be accurately guided to even relatively small targets in an organ while avoiding obstacles and overcoming undesirable deviations away from the planned path due to unforeseen or unknowable tissue interactions. This feature makes the needle especially suitable for use in image-guided surgical procedures (ranging from MRI to CT and ultrasound) when accurate targeting is imperative for good treatment outcomes. Such interventions include reaching small tumors in biopsies, delineating freezing areas in, for example, cryosurgery and improving the accuracy of seed placement in brachytherapy. Particularly relevant are prostate procedures, which may be subject to pubic arch interference. Combining diagnostic imaging and actuation assisted biopsy into one treatment can obviate the need for a second exam for guided biopsy, shorten overall procedure times (thus increasing operating room efficiencies), address healthcare reimbursement constraints and, most importantly, improve patient comfort and clinical outcomes.

  6. Intravascular OCT

    NASA Astrophysics Data System (ADS)

    Schmitt, Joseph M.; Adler, Desmond; Xu, Chenyang

    Since the first coronary angioplasty was performed in the late 1970s, imaging has played a central role in percutaneous coronary intervention (PCI). Today more than three million PCI procedures are performed worldwide to expand narrowed arteries and to clear blood clots that can cause debilitating symptoms of myocardial ischemia or fatal heart attacks. Although X-ray angiography is still the workhorse imaging modality in the field of interventional cardiology, intravascular imaging has become an indispensable tool for guiding complex PCI procedures. Intravascular ultrasound (IVUS) and optical coherence tomography (OCT) are the two most commonly used catheter-based imaging technologies in coronary procedures. Since the first commercial intravascular OCT systems were introduced in Japan and the European Union in 2004 and in the United States in 2009, the application of intravascular OCT has grown rapidly [3, 15, 16].

  7. Needle tip visibility in 3D ultrasound images

    NASA Astrophysics Data System (ADS)

    Arif, Muhammad; Moelker, Adriaan; van Walsum, Theo

    2017-03-01

    Needle visibility is of crucial importance for ultrasound guided interventional procedures. However, several factors, such as shadowing by bone or gas and tissue echogenic properties similar to needles, may compromise needle visibility. Additionally, small angle between the ultrasound beam and the needle, as well as small gauged needles may reduce visibility. Variety in needle tips design may also affect needle visibility. Whereas several studies have investigated needle visibility in 2D ultrasound imaging, no data is available for 3D ultrasound imaging, a modality that has great potential for image guidance interventions1. In this study, we evaluated needle visibility using a 3D ultrasound transducer. We examined different needles in a tissue mimicking liver phantom at three angles (200, 550 and 900) and quantify their visibility. The liver phantom was made by 5% polyvinyl alcohol solution containing 1% Silica gel particles to act as ultrasound scattering particles. We used four needles; two biopsy needles (Quick core 14G and 18G), one Ablation needle (Radiofrequency Ablation 17G), and Initial puncture needle (IP needle 17G). The needle visibility was quantified by calculating contrast to noise ratio. The results showed that the visibility for all needles were almost similar at large angles. However the difference in visibility at lower angles is more prominent. Furthermore, the visibility increases with the increase in angle of ultrasound beam with needles.

  8. A multimodal image guiding system for Navigated Ultrasound Bronchoscopy (EBUS): A human feasibility study

    PubMed Central

    Hofstad, Erlend Fagertun; Amundsen, Tore; Langø, Thomas; Bakeng, Janne Beate Lervik; Leira, Håkon Olav

    2017-01-01

    Background Endobronchial ultrasound transbronchial needle aspiration (EBUS-TBNA) is the endoscopic method of choice for confirming lung cancer metastasis to mediastinal lymph nodes. Precision is crucial for correct staging and clinical decision-making. Navigation and multimodal imaging can potentially improve EBUS-TBNA efficiency. Aims To demonstrate the feasibility of a multimodal image guiding system using electromagnetic navigation for ultrasound bronchoschopy in humans. Methods Four patients referred for lung cancer diagnosis and staging with EBUS-TBNA were enrolled in the study. Target lymph nodes were predefined from the preoperative computed tomography (CT) images. A prototype convex probe ultrasound bronchoscope with an attached sensor for position tracking was used for EBUS-TBNA. Electromagnetic tracking of the ultrasound bronchoscope and ultrasound images allowed fusion of preoperative CT and intraoperative ultrasound in the navigation software. Navigated EBUS-TBNA was used to guide target lymph node localization and sampling. Navigation system accuracy was calculated, measured by the deviation between lymph node position in ultrasound and CT in three planes. Procedure time, diagnostic yield and adverse events were recorded. Results Preoperative CT and real-time ultrasound images were successfully fused and displayed in the navigation software during the procedures. Overall navigation accuracy (11 measurements) was 10.0 ± 3.8 mm, maximum 17.6 mm, minimum 4.5 mm. An adequate sample was obtained in 6/6 (100%) of targeted lymph nodes. No adverse events were registered. Conclusions Electromagnetic navigated EBUS-TBNA was feasible, safe and easy in this human pilot study. The clinical usefulness was clearly demonstrated. Fusion of real-time ultrasound, preoperative CT and electromagnetic navigational bronchoscopy provided a controlled guiding to level of target, intraoperative overview and procedure documentation. PMID:28182758

  9. Ultrasound-guided lumbar puncture in pediatric patients: technical success and safety.

    PubMed

    Pierce, David B; Shivaram, Giri; Koo, Kevin S H; Shaw, Dennis W W; Meyer, Kirby F; Monroe, Eric J

    2018-06-01

    Disadvantages of fluoroscopically guided lumbar puncture include delivery of ionizing radiation and limited resolution of incompletely ossified posterior elements. Ultrasound (US) allows visualization of critical soft tissues and the cerebrospinal fluid (CSF) space without ionizing radiation. To determine the technical success and safety of US-guided lumbar puncture in pediatric patients. A retrospective review identified all patients referred to interventional radiology for lumbar puncture between June 2010 and June 2017. Patients who underwent lumbar puncture with fluoroscopic guidance alone were excluded. For the remaining procedures, technical success and procedural complications were assessed. Two hundred and one image-guided lumbar punctures in 161 patients were included. Eighty patients (43%) had previously failed landmark-based attempts. One hundred ninety-six (97.5%) patients underwent lumbar puncture. Five procedures (2.5%) were not attempted after US assessment, either due to a paucity of CSF or unsafe window for needle placement. Technical success was achieved in 187 (95.4%) of lumbar punctures attempted with US guidance. One hundred seventy-seven (90.3%) were technically successful with US alone (age range: 2 days-15 years, weight range: 1.9-53.1 kg) and an additional 10 (5.1%) were successful with US-guided thecal access and subsequent fluoroscopic confirmation. Three (1.5%) cases were unsuccessful with US guidance but were subsequently successful with fluoroscopic guidance. Of the 80 previously failed landmark-based lumbar punctures, 77 (96.3%) were successful with US guidance alone. There were no reported complications. US guidance is safe and effective for lumbar punctures and has specific advantages over fluoroscopy in pediatric patients.

  10. Therapeutic aspects of endoscopic ultrasound

    NASA Astrophysics Data System (ADS)

    Woodward, Timothy A.

    1999-06-01

    Endoscopic ultrasound (EUS) is a technology that had been used primarily as a passive imaging modality. Recent advances have enabled us to move beyond the use of EUS solely as a staging tool to an interventional device. Current studies suggest that interventional applications of EUS will allow for minimally invasive assessment and therapies in a cost-effective manner. Endoscopic ultrasound with fine needle aspiration (EUS-FNA) has been demonstrated to be a technically feasible, relatively safe method of obtaining cytologic specimens. The clinical utility of EUS- FNA appears to be greatest in the diagnosis and staging of pancreatic cancer and in the nodal staging of gastrointestinal and pulmonary malignancies. In addition, EUS-FNA has demonstrated utility in the sampling pleural and ascitic fluid not generally appreciated or assessable to standard interventions. Interventional applications of EUS include EUS-guided pseudocyst drainage, EUS-guided injection of botulinum toxin in the treatment of achalasia, and EUS- guided celiac plexus neurolysis in the treatment of pancreatic cancer pain. Finally, EUS-guided fine-needle installation is being evaluated, in conjunction with recent bimolecular treatment modalities, as a delivery system in the treatment of certain gastrointestinal tumors.

  11. Interventional MSK procedures: the hip.

    PubMed

    Dodré, Emilie; Lefebvre, Guillaume; Cockenpot, Eric; Chastanet, Patrick; Cotten, Anne

    2016-01-01

    Percutaneous musculoskeletal procedures are widely accepted as low invasive, highly effective, efficient and safe methods in a vast amount of hip pathologies either in diagnostic or in therapeutic management. Hip intra-articular injections are used for the symptomatic treatment of osteoarthritis. Peritendinous or intrabursal corticosteroid injections can be used for the symptomatic treatment of greater trochanteric pain syndrome and anterior iliopsoas impingement. In past decades, the role of interventional radiology has rapidly increased in metastatic disease, thanks to the development of many ablative techniques. Image-guided percutaneous ablation of skeletal metastases provides a minimally invasive treatment option that appears to be a safe and effective palliative treatment for localized painful lytic lesion. Methods of tumour destruction based on temperature, such as radiofrequency ablation (RFA) and cryotherapy, are performed for the management of musculoskeletal metastases. MR-guided focused ultrasound surgery provides a non-invasive alternative to these ablative methods. Cementoplasty is now widely used for pain management and consolidation of acetabular metastases and can be combined with RFA. RFA is also used to treat benign tumours, namely osteoid osteomas. New interventional procedures such as percutaneous screw fixation are also proposed to treat non-displaced or minimally displaced acetabular roof fractures.

  12. Delphi Method Validation of a Procedural Performance Checklist for Insertion of an Ultrasound-Guided Internal Jugular Central Line.

    PubMed

    Hartman, Nicholas; Wittler, Mary; Askew, Kim; Manthey, David

    2016-01-01

    Placement of ultrasound-guided central lines is a critical skill for physicians in several specialties. Improving the quality of care delivered surrounding this procedure demands rigorous measurement of competency, and validated tools to assess performance are essential. Using the iterative, modified Delphi technique and experts in multiple disciplines across the United States, the study team created a 30-item checklist designed to assess competency in the placement of ultrasound-guided internal jugular central lines. Cronbach α was .94, indicating an excellent degree of internal consistency. Further validation of this checklist will require its implementation in simulated and clinical environments. © The Author(s) 2014.

  13. Surgical treatment for mediastinal abscess induced by endobronchial ultrasound-guided transbronchial needle aspiration: a case report and literature review.

    PubMed

    Yokoyama, Yujiro; Nakagomi, Takahiro; Shikata, Daichi; Higuchi, Rumi; Oyama, Toshio; Goto, Taichiro

    2017-07-14

    Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a useful and less invasive procedure for the definitive diagnosis of mediastinal and hilar lymph nodes. However, infectious complications can occur after EBUS-TBNA, although they are extremely rare. A 66-year-old man with necrotic and swollen lower paratracheal lymph nodes underwent EBUS-TBNA. A mediastinal abscess developed 9 days post-procedure. Surgical drainage and debridement of the abscess were performed along with lymph node biopsy followed by daily washing of the thoracic cavity. Surgical treatment was effective, leading to remission of the abscess. Biopsy revealed that the tumor was squamous cell carcinoma with no radiologically detected cancer elsewhere in the body. Mediastinal lung cancer was thus confirmed. Subsequent chemoradiotherapy led to the remission of the tumor. Mediastinitis after EBUS-TBNA is rare but should be considered, particularly if the target lymph nodes are necrotic. Mediastinitis can lead to serious and rapid deterioration of the patient's condition, for which surgical intervention is the treatment of choice.

  14. Radiofrequency Ablation of Uterine Fibroids: a Review.

    PubMed

    Lee, Bruce B; Yu, Steve P

    2016-01-01

    Laparoscopic, ultrasound-guided radiofrequency ablation (RFA) is a new, FDA-cleared uterine sparing, outpatient procedure for uterine fibroids. The procedure utilizes recent technological advancements in instrumentation and imaging, allowing surgeons to treat numerous fibroids of varying size and location in a minimally invasive fashion. Early and mid-term data from multi-center clinical trials have demonstrated safety and efficacy, with resolution or improvement of symptoms and significant volume reduction. Re-intervention rates for fibroid symptoms have been low. The procedure is well tolerated with a typically uneventful and rapid recovery requiring NSAIDs only for postoperative pain. While post RFA pregnancy data are limited, the results are promising.

  15. [Thoracic ultrasound: the pneumologist's new stethoscope].

    PubMed

    Heinen, V; Duysinx, B; Corhay, J L; Louis, R

    2012-10-01

    We now have access to a large library of publications validating transparietal thoracic echography in various clinical situations. Parietal lesions, including osteolysis, can be detected and biopsied during the thoracic ultrasound (TUS) examination. To evaluate the parietal extension of lung cancers, TUS has proved superior to tomodensitometry. Pleural effusions can be easily diagnosed and aspirated. Pneumothoraces can be detected using well defined lung artifacts with a high frequency probe. Pleural and peripheral lung nodules can be detected and biopsied with real time visualization; the procedure is safe and accurate. Lung consolidations with a pleural contact can be diagnosed; this is particularly useful for pregnant women. In conclusion, TUS is a precious diagnostic tool for chosen applications, and can help to guide interventional procedures. The portable devices are also very useful for bedridden patients or for out of hospital use.

  16. Improving needle tip identification during ultrasound-guided procedures in anaesthetic practice.

    PubMed

    Scholten, H J; Pourtaherian, A; Mihajlovic, N; Korsten, H H M; A Bouwman, R

    2017-07-01

    Ultrasound guidance is becoming standard practice for needle-based interventions in anaesthetic practice, such as vascular access and peripheral nerve blocks. However, difficulties in aligning the needle and the transducer can lead to incorrect identification of the needle tip, possibly damaging structures not visible on the ultrasound screen. Additional techniques specifically developed to aid alignment of needle and probe or identification of the needle tip are now available. In this scoping review, advantages and limitations of the following categories of those solutions are presented: needle guides; alterations to needle or needle tip; three- and four-dimensional ultrasound; magnetism, electromagnetic or GPS systems; optical tracking; augmented (virtual) reality; robotic assistance; and automated (computerised) needle detection. Most evidence originates from phantom studies, case reports and series, with few randomised clinical trials. Improved first-pass success and reduced performance time are the most frequently cited benefits, whereas the need for additional and often expensive hardware is the greatest limitation to widespread adoption. Novice ultrasound users seem to benefit most and great potential lies in education. Future research should focus on reporting relevant clinical parameters to learn which technique will benefit patients most in terms of success and safety. © 2017 The Association of Anaesthetists of Great Britain and Ireland.

  17. Ultrasound-Guided Intervention for Treatment of Trigeminal Neuralgia: An Updated Review of Anatomy and Techniques

    PubMed Central

    Allam, Abdallah El-Sayed; Khalil, Adham Aboul Fotouh; Eltawab, Basma Aly; Wu, Wei-Ting

    2018-01-01

    Orofacial myofascial pain is prevalent and most often results from entrapment of branches of the trigeminal nerves. It is challenging to inject branches of the trigeminal nerve, a large portion of which are shielded by the facial bones. Bony landmarks of the cranium serve as important guides for palpation-guided injections and can be delineated using ultrasound. Ultrasound also provides real-time images of the adjacent muscles and accompanying arteries and can be used to guide the needle to the target region. Most importantly, ultrasound guidance significantly reduces the risk of collateral injury to vital neurovascular structures. In this review, we aimed to summarize the regional anatomy and ultrasound-guided injection techniques for the trigeminal nerve and its branches, including the supraorbital, infraorbital, mental, auriculotemporal, maxillary, and mandibular nerves. PMID:29808105

  18. Core review: physician-performed ultrasound: the time has come for routine use in acute care medicine.

    PubMed

    Royse, Colin F; Canty, David J; Faris, John; Haji, Darsim L; Veltman, Michael; Royse, Alistair

    2012-11-01

    The use of ultrasound in the acute care specialties of anesthesiology, intensive care, emergency medicine, and surgery has evolved from discrete, office-based echocardiographic examinations to the real-time or point-of-care clinical assessment and interventions. "Goal-focused" transthoracic echocardiography is a limited scope (as compared with comprehensive examination) echocardiographic examination, performed by the treating clinician in acute care medical practice, and is aimed at addressing specific clinical concerns. In the future, the practice of surface ultrasound will be integrated into the everyday clinical practice as ultrasound-assisted examination and ultrasound-guided procedures. This evolution should start at the medical student level and be reinforced throughout specialist training. The key to making ultrasound available to every physician is through education programs designed to facilitate uptake, rather than to prevent access to this technology and education by specialist craft groups. There is evidence that diagnosis is improved with ultrasound examination, yet data showing change in management and improvement in patient outcome are few and an important area for future research.

  19. Combined magnetic resonance imaging and ultrasound echography guidance for motion compensated HIFU interventions

    NASA Astrophysics Data System (ADS)

    Ries, Mario; de Senneville, Baudouin Denis; Regard, Yvan; Moonen, Chrit

    2012-11-01

    The objective of this study is to evaluate the feasibility to integrate ultrasound echography as an additional imaging modality for continuous target tracking, while performing simultaneously real-time MR- thermometry to guide a High Intensity Focused Ultrasound (HIFU) ablation. Experiments on a moving phantom were performed with MRI-guided HIFU during continuous ultrasound echography. Real-time US echography-based target tracking during MR-guided HIFU heating was performed with heated area dimensions similar to those obtained for a static target. The combination of both imaging modalities shows great potential for real-time beam steering and MR-thermometry.

  20. Application of ultrasound in the assessment of plantar fascia in patients with plantar fasciitis: a systematic review.

    PubMed

    Mohseni-Bandpei, Mohammad Ali; Nakhaee, Masoomeh; Mousavi, Mohammad Ebrahim; Shakourirad, Ali; Safari, Mohammad Reza; Vahab Kashani, Reza

    2014-08-01

    Plantar fasciitis (PFS) is one of the most common causes of heel pain, estimated to affect 10% of the general population during their lifetime. Ultrasound (US) imaging technique is increasingly being used to assess plantar fascia (PF) thickness, monitor the effect of different interventions and guide therapeutic interventions in patients with PFS. The purpose of the present study was to systematically review previously published studies concerning the application of US in the assessment of PF in patients with PFS. A literature search was performed for the period 2000-2012 using the Science Direct, Scopus, PubMed, CINAHL, Medline, Embase and Springer databases. The key words used were: ultrasound, sonography, imaging techniques, ultrasonography, interventional ultrasonography, plantar fascia and plantar fasciitis. The literature search yielded 34 relevant studies. Sixteen studies evaluated the effect of different interventions on PF thickness in patients with PFS using US; 12 studies compared PF thickness between patients with and without PFS using US; 6 studies investigated the application of US as a guide for therapeutic intervention in patients with PFS. There were variations among studies in terms of methodology used. The results indicated that US can be considered a reliable imaging technique for assessing PF thickness, monitoring the effect of different interventions and guiding therapeutic interventions in patients with PFS. Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  1. Immediate postpartum ultrasound evaluation for suspected retained placental tissue in patients undergoing manual removal of placenta.

    PubMed

    Weissbach, T; Haikin-Herzberger, E; Bacci-Hugger, K; Shechter-Maor, G; Fejgin, M; Biron-Shental, T

    2015-09-01

    Approximately 1% of term deliveries are complicated by retained products of conception. Untreated, this condition may cause bleeding, infection and intrauterine adhesions. This study assessed whether performing routine bedside uterine ultrasound immediately after manual removal of the placenta reduced the occurrence of undiagnosed, retained products of conception and its associated complications. A retrospective study was conducted using the records of patients who delivered and underwent manual removal of placenta at a single obstetrics center over a 6-year period. The outcomes of patients who were assessed using immediate bedside ultrasound were compared to a similar group who were treated based on clinical evaluation alone. All patients underwent ultrasound examination prior to discharge. Outcome variables included the rate of additional interventions (medical or surgical), abnormal pre-discharge uterine ultrasound findings, postpartum hemorrhage rate, puerperal fever and length of hospital stay. A total of 399 charts were reviewed. Immediate post-procedural ultrasound was performed in 235 patients. The remaining 164 women did not undergo immediate post-procedural ultrasound. All patients underwent an ultrasound examination prior to discharge. Among the patients who had an immediate post-procedural ultrasound, 12 (5.1%) received immediate re-intervention (2 methergine, 6 curettage and 4 manual uterine revision) vs. no intervention in the second group (p<0.001). No statistically significant difference was found between the group of patients who had immediate post-procedural ultrasound and those who did not, in the rates of postpartum hemorrhage (3.1% vs. 0.7%, p=0.13), abnormal ultrasound findings prior to discharge (14.9% vs. 14.8%, p=0.96) or additional late intervention (7.2% vs. 7.9%, p=0.79), respectively. Our findings suggest that immediate, bedside uterine ultrasound examination after manual removal of placenta might not change patient outcomes. Furthermore, it might increase unnecessary interventions. Further studies are needed to prospectively assess the benefit of routine uterine ultrasound examination after manual removal of placenta. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  2. Virtual reality, ultrasound-guided liver biopsy simulator: development and performance discrimination

    PubMed Central

    Johnson, S J; Hunt, C M; Woolnough, H M; Crawshaw, M; Kilkenny, C; Gould, D A; England, A; Sinha, A; Villard, P F

    2012-01-01

    Objectives The aim of this article was to identify and prospectively investigate simulated ultrasound-guided targeted liver biopsy performance metrics as differentiators between levels of expertise in interventional radiology. Methods Task analysis produced detailed procedural step documentation allowing identification of critical procedure steps and performance metrics for use in a virtual reality ultrasound-guided targeted liver biopsy procedure. Consultant (n=14; male=11, female=3) and trainee (n=26; male=19, female=7) scores on the performance metrics were compared. Ethical approval was granted by the Liverpool Research Ethics Committee (UK). Independent t-tests and analysis of variance (ANOVA) investigated differences between groups. Results Independent t-tests revealed significant differences between trainees and consultants on three performance metrics: targeting, p=0.018, t=−2.487 (−2.040 to −0.207); probe usage time, p = 0.040, t=2.132 (11.064 to 427.983); mean needle length in beam, p=0.029, t=−2.272 (−0.028 to −0.002). ANOVA reported significant differences across years of experience (0–1, 1–2, 3+ years) on seven performance metrics: no-go area touched, p=0.012; targeting, p=0.025; length of session, p=0.024; probe usage time, p=0.025; total needle distance moved, p=0.038; number of skin contacts, p<0.001; total time in no-go area, p=0.008. More experienced participants consistently received better performance scores on all 19 performance metrics. Conclusion It is possible to measure and monitor performance using simulation, with performance metrics providing feedback on skill level and differentiating levels of expertise. However, a transfer of training study is required. PMID:21304005

  3. Radiation Exposure in Transjugular Intrahepatic Portosystemic Shunt Creation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miraglia, Roberto, E-mail: rmiraglia@ismett.edu; Maruzzelli, Luigi, E-mail: lmaruzzelli@ismett.edu; Cortis, Kelvin, E-mail: kelvincortis@ismett.edu

    2016-02-15

    PurposeTransjugular intrahepatic portosystemic shunt (TIPS) creation is considered as being one of the most complex procedures in abdominal interventional radiology. Our aim was twofold: quantification of TIPS-related patient radiation exposure in our center and identification of factors leading to reduced radiation exposure.Materials and methodsThree hundred and forty seven consecutive patients underwent TIPS in our center between 2007 and 2014. Three main procedure categories were identified: Group I (n = 88)—fluoroscopic-guided portal vein targeting, procedure done in an image intensifier-based angiographic system (IIDS); Group II (n = 48)—ultrasound-guided portal vein puncture, procedure done in an IIDS; and Group III (n = 211)—ultrasound-guided portal vein puncture, procedure donemore » in a flat panel detector-based system (FPDS). Radiation exposure (dose-area product [DAP], in Gy cm{sup 2} and fluoroscopy time [FT] in minutes) was retrospectively analyzed.ResultsDAP was significantly higher in Group I (mean ± SD 360 ± 298; median 287; 75th percentile 389 Gy cm{sup 2}) as compared to Group II (217 ± 130; 178; 276 Gy cm{sup 2}; p = 0.002) and Group III (129 ± 117; 70; 150 Gy cm{sup 2}p < 0.001). The difference in DAP between Groups II and III was also significant (p < 0.001). Group I had significantly longer FT (25.78 ± 13.52 min) as compared to Group II (20.45 ± 10.87 min; p = 0.02) and Group III (19.76 ± 13.34; p < 0.001). FT was not significantly different between Groups II and III (p = 0.73).ConclusionsReal-time ultrasound-guided targeting of the portal venous system during TIPS creation results in a significantly lower radiation exposure and reduced FT. Further reduction in radiation exposure can be achieved through the use of modern angiographic units with FPDS.« less

  4. Disinfection of a probe used in ultrasound-guided prostate biopsy.

    PubMed

    Rutala, William A; Gergen, Maria F; Weber, David J

    2007-08-01

    Transrectal ultrasound (TRUS)-guided prostate biopsies are among the most common outpatient diagnostic procedures in urology clinics and carry the risk of introducing pathogens that may lead to infection. To investigate the effectiveness of procedures for disinfecting a probe used in ultrasound-guided prostate biopsy. The effectiveness of disinfection was determined by inoculating 10(7) colony forming units (cfu) of Pseudomonas aeruginosa at the following 3 sites on the probe: the interior lumen of the biopsy needle guide, the outside surface of the biopsy needle guide, and the interior lumen of the ultrasound probe where the needle guide passes through the transducer. Each site was investigated separately. After inoculation, the probe was immersed in 2% glutaraldehyde for 20 minutes and then assessed for the level of microbial contamination. The results demonstrated that disinfection (ie, a reduction in bacterial load of greater than 7 log(10) cfu) could be achieved if the needle guide was removed from the probe. However, if the needle guide was left in the probe channel during immersion in 2% glutaraldehyde, disinfection was not achieved (ie, the reduction was approximately 1 log(10) cfu). Recommendations for probe disinfection are provided and include disassembling the device and immersing the probe and the needle guide separately in a high-level disinfectant.

  5. Pancreatic pseudocyst drainage performed with a new prototype forward-viewing linear echoendoscope.

    PubMed

    Fernández de Castro, Cristina; Cañete, Ángel; Sanz de Villalobos, Eduardo; Ferreiro, Reyes; Albillos Martínez, Agustín; Vázquez Sequeiros, Enrique

    2016-10-01

    Interventional endoscopy is a field that continues to grow rapidly. A novel prototype forward-viewing echoendoscope (FV-EUS) has been recently developed in an attempt to overcome some of the limitations of conventional curved linear-array echoendoscopes (OV-EUS). We present a case of a successful endoscopic ultrasound-guided drainage of a pancreatic pseudocyst using a forward-viewing echoendoscope. Although the utilization use of this newly developed echoendoscope has not yet become widespread, its unique characteristics can help to easily perform routine therapeutic procedures and contribute to the expansion of interventional endoscopic utrasoundultrasound.

  6. MO-DE-202-01: Image-Guided Focused Ultrasound Surgery and Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Farahani, K.

    At least three major trends in surgical intervention have emerged over the last decade: a move toward more minimally invasive (or non-invasive) approach to the surgical target; the development of high-precision treatment delivery techniques; and the increasing role of multi-modality intraoperative imaging in support of such procedures. This symposium includes invited presentations on recent advances in each of these areas and the emerging role for medical physics research in the development and translation of high-precision interventional techniques. The four speakers are: Keyvan Farahani, “Image-guided focused ultrasound surgery and therapy” Jeffrey H. Siewerdsen, “Advances in image registration and reconstruction for image-guidedmore » neurosurgery” Tina Kapur, “Image-guided surgery and interventions in the advanced multimodality image-guided operating (AMIGO) suite” Raj Shekhar, “Multimodality image-guided interventions: Multimodality for the rest of us” Learning Objectives: Understand the principles and applications of HIFU in surgical ablation. Learn about recent advances in 3D–2D and 3D deformable image registration in support of surgical safety and precision. Learn about recent advances in model-based 3D image reconstruction in application to intraoperative 3D imaging. Understand the multi-modality imaging technologies and clinical applications investigated in the AMIGO suite. Understand the emerging need and techniques to implement multi-modality image guidance in surgical applications such as neurosurgery, orthopaedic surgery, vascular surgery, and interventional radiology. Research supported by the NIH and Siemens Healthcare.; J. Siewerdsen; Grant Support - National Institutes of Health; Grant Support - Siemens Healthcare; Grant Support - Carestream Health; Advisory Board - Carestream Health; Licensing Agreement - Carestream Health; Licensing Agreement - Elekta Oncology.; T. Kapur, P41EB015898; R. Shekhar, Funding: R42CA137886 and R41CA192504 Disclosure and CoI: IGI Technologies, small-business partner on the grants.« less

  7. Quality of Widely Available Video Instructional Materials for Point-of-Care Ultrasound-Guided Procedure Training in Internal Medicine.

    PubMed

    Khandelwal, Aditi; Devine, Luke A; Otremba, Mirek

    2017-07-01

    Many instructional materials for point-of-care ultrasound (US)-guided procedures exist; however, their quality is unknown. This study assessed widely available educational videos for point-of-care US-guided procedures relevant to internal medicine: central venous catheterization, thoracentesis, and paracentesis. We searched Ovid MEDLINE, YouTube, and Google to identify videos for point-of-care US-guided paracentesis, thoracentesis, and central venous catheterization. Videos were evaluated with a 5-point scale assessing the global educational value and a checklist based on consensus guidelines for competencies in point-of-care US-guided procedures. For point-of-care US-guided central venous catheterization, 12 videos were found, with an average global educational value score ± SD of 4.5 ± 0.7. Indications to abort the procedure were discussed in only 3 videos. Five videos described the indications and contraindications for performing central venous catheterization. For point-of-care US-guided thoracentesis, 8 videos were identified, with an average global educational value score of 4.0 ± 0.9. Only one video discussed indications to abort the procedure, and 3 videos discussed sterile technique. For point-of-care US-guided paracentesis, 7 videos were included, with an average global educational value score of 4.1 ± 0.9. Only 1 video discussed indications to abort the procedure, and 2 described the location of the inferior epigastric artery. The 27 videos reviewed contained good-quality general instruction. However, we noted a lack of safety-related information in most of the available videos. Further development of resources is required to teach internal medicine trainees skills that focus on the safety of point-of-care US guidance. © 2017 by the American Institute of Ultrasound in Medicine.

  8. Ultrasound-guided injection of triamcinolone and bupivacaine in the management of De Quervain's disease.

    PubMed

    Jeyapalan, Kanagaratnam; Choudhary, Surabhi

    2009-11-01

    The aim of this study was to describe the technique and usefulness of ultrasound-guided intrasynovial injection of triamcinolone and bupivacaine in treatment of de Quervain's disease. A total of 17 patients with symptomatic De Quervain's disease were included in this study. The procedure involved confirmation of diagnosis with ultrasound followed by guided injection of a mixture of 20 mg of triamcinolone (40 mg/ml) and 1 ml of 0.5% bupivacaine. Ultrasound guidance with a high resolution 15-Mhz footprint probe was used for injection into the first dorsal extensor compartment tendon sheath (E1). The response to ultrasound-guided injection was ascertained at the post procedure outpatient clinic appointment according to the follow-up clinic notes. There were 14 female and 3 male patients aged 29 to 74 years. Mean duration of symptoms was 8.9 months. One patient had an atypical septum in the first extensor compartment and the extensor pollicis brevis alone was involved. The mean post-injection follow-up was at 6.75 weeks. One patient was lost to follow-up. Fifteen out of 16 patients had significant symptomatic relief (93.75%). There were no immediate or delayed complications. Recurrence of symptoms was seen in 3 (20%) patients. Ultrasound-guided injection of triamcinolone and bupivacaine is safe and useful in controlling symptoms of De Quervain's disease. Correct needle placement with ultrasound guidance avoids intratendinous injection as well as local complications like fat atrophy and depigmentation.

  9. Clinical use of intracoronary imaging. Part 1: guidance and optimization of coronary interventions. An expert consensus document of the European Association of Percutaneous Cardiovascular Interventions: Endorsed by the Chinese Society of Cardiology.

    PubMed

    Räber, Lorenz; Mintz, Gary S; Koskinas, Konstantinos C; Johnson, Thomas W; Holm, Niels R; Onuma, Yoshinubo; Radu, Maria D; Joner, Michael; Yu, Bo; Jia, Haibo; Menevau, Nicolas; de la Torre Hernandez, Jose M; Escaned, Javier; Hill, Jonathan; Prati, Francesco; Colombo, Antonio; di Mario, Carlo; Regar, Evelyn; Capodanno, Davide; Wijns, William; Byrne, Robert A; Guagliumi, Giulio

    2018-05-22

    This Consensus Document is the first of two reports summarizing the views of an expert panel organized by the European Association of Percutaneous Cardiovascular Interventions (EAPCI) on the clinical use of intracoronary imaging including intravascular ultrasound (IVUS) and optical coherence tomography (OCT). The first document appraises the role of intracoronary imaging to guide percutaneous coronary interventions (PCIs) in clinical practice. Current evidence regarding the impact of intracoronary imaging guidance on cardiovascular outcomes is summarized, and patients or lesions most likely to derive clinical benefit from an imaging-guided intervention are identified. The relevance of the use of IVUS or OCT prior to PCI for optimizing stent sizing (stent length and diameter) and planning the procedural strategy is discussed. Regarding post-implantation imaging, the consensus group recommends key parameters that characterize an optimal PCI result and provides cut-offs to guide corrective measures and optimize the stenting result. Moreover, routine performance of intracoronary imaging in patients with stent failure (restenosis or stent thrombosis) is recommended. Finally, strengths and limitations of IVUS and OCT for guiding PCI and assessing stent failures and areas that warrant further research are critically discussed.

  10. Technical tips for peroral transluminal cholangioscopy using novel single-operator cholangioscope (with videos).

    PubMed

    Ogura, Takeshi; Takagi, Wataru; Kurisu, Yoshitaka; Higuchi, Kazuhide

    2016-10-01

    Endoscopic retrograde cholangiopancreatography (ERCP) is the gold-standard modality for diagnosis and therapy of bilio-pancreatic disease. In particular, peroral cholangiography (POCS) is a useful modality not only for diagnosing biliary disease, but also for therapeutic procedures such as electrohydraulic lithotripsy. The SPY-DS single-operator cholangioscope has recently become available, and offers favorable visualization, a wide view, suction function and a larger accessory working channel. However, if the duodenoscope cannot be advanced into the ampulla of Vater for reasons such as surgical anatomy, POCS cannot be performed. On the other hand, percutaneous transhepatic cholangiodrainage (PTCD) has been developed as an alternative endoscopic ultrasound-guided approach to the biliary tract. Peroral transluminal cholangioscopy (PTLC) using SPY-DS is a novel approach. Because transluminal interventional procedures under endoscopic ultrasound guidance have recently been developed, our technique may have clinical impact for selected cases. © 2016 Japanese Society of Hepato-Biliary-Pancreatic Surgery.

  11. Ultrasound-guided intrasphincteric botulinum toxin injection relieves obstructive defecation due to Hirschsprung's disease and internal anal sphincter achalasia.

    PubMed

    Church, Joseph T; Gadepalli, Samir K; Talishinsky, Toghrul; Teitelbaum, Daniel H; Jarboe, Marcus D

    2017-01-01

    Chronic obstructive defecation can occur in patients with Hirschsprung Disease (HD) and internal anal sphincter (IAS) achalasia. Injection of Botulinum Toxin (BoTox) into the IAS can temporarily relieve obstructive defecation, but can be challenging when performed by tactile sense alone. We compared results of BoTox injections with and without ultrasound (US) guidance. We retrospectively reviewed BoTox injections into the IAS for obstructive defecation over 5years. Analyzed outcomes included short-term improvement, defined as resolution of enterocolitis, new ability to spontaneously defecate, and/or normalization of bowel movement frequency 2weeks post-operatively, as well as requirement of more definitive surgical therapy (myotomy/myomectomy, colectomy, colostomy, cecostomy/appendicostomy, and/or sacral nerve stimulator implantation). Outcomes were compared using t-test and Fisher's Exact test, with significance defined as p<0.05. Twelve patients who underwent BoTox injection were included, including 5 patients who underwent injections both with and without ultrasound. Ten underwent an ultrasound-guided injection (13 injection procedures), 5 of whom had HD. Seven underwent an injection without ultrasound guidance (17 injection procedures), 5 of whom had HD. Procedures performed with US resulted in greater short-term improvement (76% versus 65% without ultrasound) and less requirement of a definitive procedure for obstructive defecation (p<0.05). US-guided BoTox injection is safe and effective for obstructive defecation, and may decrease the need for a definitive operation. III. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Percutaneous Ultrasound-Guided Carpal Tunnel Release: Study Upon Clinical Efficacy and Safety

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Petrover, David, E-mail: dpetrover@yahoo.fr; Silvera, Jonathan, E-mail: silvera.jonathan@gmail.com; Baere, Thierry De, E-mail: Debaere@igr.fr

    ObjectivesTo evaluate the feasibility and 6 months clinical result of sectioning of the transverse carpal ligament (TCL) and median nerve decompression after ultra-minimally invasive, ultrasound-guided percutaneous carpal tunnel release (PCTR) surgery.MethodsConsecutive patients with carpal tunnel syndrome were enrolled in this descriptive, open-label study. The procedure was performed in the interventional radiology room. Magnetic resonance imaging was performed at baseline and 1 month. The Boston Carpal Tunnel Questionnaire was administered at baseline, 1, and 6 months.Results129 patients were enrolled. Significant decreases in mean symptom severity scores (3.3 ± 0.7 at baseline, 1.7 ± 0.4 at Month 1, 1.3 ± 0.3 at Month 6) and mean functional status scores (2.6 ± 1.1 atmore » baseline, 1.6 ± 0.4 at Month 1, 1.3 ± 0.5 at Month 6) were noted. Magnetic resonance imaging showed a complete section of all TCL and nerve decompression in 100% of patients. No complications were identified.ConclusionsUltrasound-guided PCTR was used successfully to section the TCL, decompress the median nerve, and reduce self-reported symptoms.« less

  13. Toward dynamic lumbar punctures guidance based on single element synthetic tracked aperture ultrasound imaging

    NASA Astrophysics Data System (ADS)

    Zhang, Haichong K.; Lin, Melissa; Kim, Younsu; Paredes, Mateo; Kannan, Karun; Patel, Nisu; Moghekar, Abhay; Durr, Nicholas J.; Boctor, Emad M.

    2017-03-01

    Lumbar punctures (LPs) are interventional procedures used to collect cerebrospinal fluid (CSF), a bodily fluid needed to diagnose central nervous system disorders. Most lumbar punctures are performed blindly without imaging guidance. Because the target window is small, physicians can only accurately palpate the appropriate space about 30% of the time and perform a successful procedure after an average of three attempts. Although various forms of imaging based guidance systems have been developed to aid in this procedure, these systems complicate the procedure by including independent image modalities and requiring image-to-needle registration to guide the needle insertion. Here, we propose a simple and direct needle insertion platform utilizing a single ultrasound element within the needle through dynamic sensing and imaging. The needle-shaped ultrasound transducer can not only sense the distance between the tip and a potential obstacle such as bone, but also visually locate structures by combining transducer location tracking and back projection based tracked synthetic aperture beam-forming algorithm. The concept of the system was validated through simulation first, which revealed the tolerance to realistic error. Then, the initial prototype of the single element transducer was built into a 14G needle, and was mounted on a holster equipped with a rotation tracking encoder. We experimentally evaluated the system using a metal wire phantom mimicking high reflection bone structures and an actual spine bone phantom with both the controlled motion and freehand scanning. An ultrasound image corresponding to the model phantom structure was reconstructed using the beam-forming algorithm, and the resolution was improved compared to without beam-forming. These results demonstrated the proposed system has the potential to be used as an ultrasound imaging system for lumbar puncture procedures.

  14. Ultrasound-guided greater occipital nerve blocks and pulsed radiofrequency ablation for diagnosis and treatment of occipital neuralgia.

    PubMed

    Vanderhoek, Matthew David; Hoang, Hieu T; Goff, Brandon

    2013-09-01

    Occipital neuralgia is a condition manifested by chronic occipital headaches and is thought to be caused by irritation or trauma to the greater occipital nerve (GON). Treatment for occipital neuralgia includes medications, nerve blocks, and pulsed radiofrequency ablation (PRFA). Landmark-guided GON blocks are the mainstay in both the diagnosis and treatment of occipital neuralgia. Ultrasound is being utilized more and more in the chronic pain clinic to guide needle advancement when performing procedures; however, there are no reports of ultrasound used to guide a diagnostic block or PRFA of the GON. We report two cases in which ultrasound was used to guide diagnostic greater occipital nerve blocks and greater occipital nerve pulsed radiofrequency ablation for treatment of occipital neuralgia. Two patients with occipital headaches are presented. In Case 1, ultrasound was used to guide diagnostic blocks of the greater occipital nerves. In Case 2, ultrasound was utilized to guide placement of radiofrequency probes for pulsed radiofrequency ablation of the greater occipital nerves. Both patients reported immediate, significant pain relief, with continued pain relief for several months. Further study is needed to examine any difference in outcomes or morbidity between the traditional landmark method versus ultrasound-guided blocks and pulsed radiofrequency ablation of the greater occipital nerves.

  15. Ultrasound-Guided Greater Occipital Nerve Blocks and Pulsed Radiofrequency Ablation for Diagnosis and Treatment of Occipital Neuralgia

    PubMed Central

    VanderHoek, Matthew David; Hoang, Hieu T; Goff, Brandon

    2013-01-01

    Occipital neuralgia is a condition manifested by chronic occipital headaches and is thought to be caused by irritation or trauma to the greater occipital nerve (GON). Treatment for occipital neuralgia includes medications, nerve blocks, and pulsed radiofrequency ablation (PRFA). Landmark-guided GON blocks are the mainstay in both the diagnosis and treatment of occipital neuralgia. Ultrasound is being utilized more and more in the chronic pain clinic to guide needle advancement when performing procedures; however, there are no reports of ultrasound used to guide a diagnostic block or PRFA of the GON. We report two cases in which ultrasound was used to guide diagnostic greater occipital nerve blocks and greater occipital nerve pulsed radiofrequency ablation for treatment of occipital neuralgia. Two patients with occipital headaches are presented. In Case 1, ultrasound was used to guide diagnostic blocks of the greater occipital nerves. In Case 2, ultrasound was utilized to guide placement of radiofrequency probes for pulsed radiofrequency ablation of the greater occipital nerves. Both patients reported immediate, significant pain relief, with continued pain relief for several months. Further study is needed to examine any difference in outcomes or morbidity between the traditional landmark method versus ultrasound-guided blocks and pulsed radiofrequency ablation of the greater occipital nerves. PMID:24282778

  16. Navigation concepts for magnetic resonance imaging-guided musculoskeletal interventions.

    PubMed

    Busse, Harald; Kahn, Thomas; Moche, Michael

    2011-08-01

    Image-guided musculoskeletal (MSK) interventions are a widely used alternative to open surgical procedures for various pathological findings in different body regions. They traditionally involve one of the established x-ray imaging techniques (radiography, fluoroscopy, computed tomography) or ultrasound scanning. Over the last decades, magnetic resonance imaging (MRI) has evolved into one of the most powerful diagnostic tools for nearly the whole body and has therefore been increasingly considered for interventional guidance as well.The strength of MRI for MSK applications is a combination of well-known general advantages, such as multiplanar and functional imaging capabilities, wide choice of tissue contrasts, and absence of ionizing radiation, as well as a number of MSK-specific factors, for example, the excellent depiction of soft-tissue tumors, nonosteolytic bone changes, and bone marrow lesions. On the downside, the magnetic resonance-compatible equipment needed, restricted space in the magnet, longer imaging times, and the more complex workflow have so far limited the number of MSK procedures under MRI guidance.Navigation solutions are generally a natural extension of any interventional imaging system, in particular, because powerful hardware and software for image processing have become routinely available. They help to identify proper access paths, provide accurate feedback on the instrument positions, facilitate the workflow in an MRI environment, and ultimately contribute to procedural safety and success.The purposes of this work were to describe some basic concepts and devices for MRI guidance of MSK procedures and to discuss technical and clinical achievements and challenges for some selected implementations.

  17. Real-time ultrasound-guided spinal anesthesia using the SonixGPS ultrasound guidance system: a feasibility study.

    PubMed

    Niazi, A U; Chin, K J; Jin, R; Chan, V W

    2014-08-01

    Real-time ultrasound-guided neuraxial blockade remains a largely experimental technique. SonixGPS® is a new needle tracking system that displays needle tip position on the ultrasound screen. We investigated if this novel technology might aid performance of real-time ultrasound-guided spinal anesthesia. Twenty patients with body mass index < 35 kg/m(2) undergoing elective total joint arthroplasty under spinal anesthesia were recruited. Patients with previous back surgery and spinal abnormalities were excluded. Following a pre-procedural ultrasound scan, a 17G proprietary needle-sensor assembly was inserted in-plane to the transducer in four patients and out-of-plane in 16 patients. In both approaches, the trajectory of insertion was adjusted in real-time until the needle tip lay just superficial to the ligamentum flavum-dura mater complex. At this point, a 25G 120 mm Whitacre spinal needle was inserted through the 17G SonixGPS® needle. Successful dural puncture was confirmed by backflow of cerebrospinal fluid from the spinal needle. An overall success rate of 14/20 (70%) was seen with two failures (50%) and four failures (25%) in the in-plane and out-of-plane groups respectively. Dural puncture was successful on the first skin puncture in 71% of patients and in a single needle pass in 57% of patients. The median total procedure time was 16.4 and 11.1 min in the in-plane and out-of-plane groups respectively. The SonixGPS® system simplifies real-time ultrasound-guided spinal anesthesia to a large extent, especially the out-of-plane approach. Nevertheless, it remains a complex multi-step procedure that requires time, specialized equipment, and a working knowledge of spinal sonoanatomy. © 2014 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  18. Towards real time 2D to 3D registration for ultrasound-guided endoscopic and laparoscopic procedures.

    PubMed

    San José Estépar, Raúl; Westin, Carl-Fredrik; Vosburgh, Kirby G

    2009-11-01

    A method to register endoscopic and laparoscopic ultrasound (US) images in real time with pre-operative computed tomography (CT) data sets has been developed with the goal of improving diagnosis, biopsy guidance, and surgical interventions in the abdomen. The technique, which has the potential to operate in real time, is based on a new phase correlation technique: LEPART, which specifies the location of a plane in the CT data which best corresponds to the US image. Validation of the method was carried out using an US phantom with cyst regions and with retrospective analysis of data sets from animal model experiments. The phantom validation study shows that local translation displacements can be recovered for each US frame with a root mean squared error of 1.56 +/- 0.78 mm in less than 5 sec, using non-optimized algorithm implementations. A new method for multimodality (preoperative CT and intraoperative US endoscopic images) registration to guide endoscopic interventions was developed and found to be efficient using clinically realistic datasets. The algorithm is inherently capable of being implemented in a parallel computing system so that full real time operation appears likely.

  19. In-Plane Ultrasound-Guided Knee Injection Through a Lateral Suprapatellar Approach: A Safe Technique.

    PubMed

    Chagas-Neto, Francisco A; Taneja, Atul K; Gregio-Junior, Everaldo; Nogueira-Barbosa, Marcello H

    2017-06-01

    This study aims to describe a technique for in-plane ultrasound-guided knee arthrography through a lateral suprapatellar approach, reporting its accuracy and related complications. A retrospective search was performed for computed tomography and magnetic resonance reports from June 2013 through June 2015. Imaging studies, puncture descriptions, and guided-procedure images were reviewed along with clinical and surgical history. A fellowship-trained musculoskeletal radiologist performed all procedures under sterile technique and ultrasound guidance with the probe in oblique position on the lateral suprapatellar recess after local anesthesia with the patient on dorsal decubitus, hip in neutral rotation, and 30 to 45 degrees of knee flexion. A total of 86 consecutive subjects were evaluated (mean, 55 years). All subjects underwent intra-articular injection of contrast, which was successfully reached in the first attempt in 94.2% of the procedures (81/86), and in the second attempt in 5.8% (5/86) after needle repositioning without a second puncture. There were no postprocedural reports of regional complications at the puncture site, such as significant pain, bleeding, or vascular lesions. Our study demonstrates that in-plane ultrasound-guided injection of the knee in semiflexion approaching the lateral suprapatellar recess is a safe and useful technique to administer intra-articular contrast solution, as an alternative method without radiation exposure.

  20. Perioperative ultrasound-guided wire marking of calcific deposits in calcifying tendinitis of the rotator cuff.

    PubMed

    Sigg, Andreas; Draws, Detlev; Stamm, Axel; Pfeiffer, Michael

    2011-03-01

    The identification of a calcific deposit in the rotator cuff can often cause difficulties. A new technique is described to identify the calcific deposit perioperatively with a ultrasound-guided wire. The technique allows a safe direct marking of calcific deposits making the procedure faster especially in difficult cases.

  1. Ultrasound-guided Interdigital Neuroma Injections: Short-term Clinical Outcomes after a Single Percutaneous Injection—Preliminary Results

    PubMed Central

    Adler, Ronald S.; Ciavarra, Gina A.; Pavlov, Helene

    2006-01-01

    Purpose To describe the procedure of ultrasound-guided Morton’s neuroma and recurrent stump neuroma injections and early clinical outcomes after a single injection. Materials and Methods Retrospective review of 44 percutaneous ultrasound-guided neuroma injections in 24 patients who had completed clinical outcomes questionnaires. A 10-point pain scale [scale of 1 (no pain) to 10 (severe pain)] in a 7-day pain log format was distributed to patients at the time percutaneous neuroma injection was performed. Results Neuromas were clearly visualized with sonography as hypoechoic nodules and were distinguishable from other causes of forefoot pain, such as metatarsophalangeal joint synovitis and intermetatarsal bursae. The sizes of the neuromas injected ranged between 4 and 19 mm. Postinjection, all neuromas displayed increased echogenicity and/or the appearance of fluid surrounding it, confirming localization of the therapeutic mixture. We arbitrarily subdivided the pain ratings into symptomatic (greater than 4) and asymptomatic (less than or equal to 4) for statistical analysis. Average pain level pre injection was 5.2 and average pain level was 3.7 at 7 days post single injection, with 62% of the initially symptomatic patients asymptomatic on day 7 (p < 0.000001). Overall, 76% of the total number of neuromas injected once were asymptomatic on day 7. Conclusion Ultrasound can be used to accurately target Morton’s neuromas and, therefore, appropriately direct therapeutic interventions, with good short-term clinical results. PMID:18751769

  2. Outcomes of ultrasound guided renal mass biopsies.

    PubMed

    Sutherland, Edward L; Choromanska, Agnieszka; Al-Katib, Sayf; Coffey, Mary

    2018-06-01

    The purpose of this study was to evaluate the rate of nondiagnostic ultrasound-guided renal mass biopsies (RMBs) at our institution and to determine what patient, procedural, and focal renal mass (FRM) factors were associated with nondiagnostic ultrasound-guided RMBs. Eighty-two ultrasound-guided renal mass biopsies performed between January 2014 and October 2016 were included in our study. Biopsy outcomes (diagnostic vs. nondiagnostic) and patient, procedural, and FRM characteristics were retrospectively reviewed and recorded. Univariate statistical analyses were performed to identify biopsy characteristics that were indicative of nondiagnostic biopsy. Ultrasound-guided RMBs were diagnostic in 70 out of 82 cases (85%) and non-diagnostic in 12 cases (15%). Among the diagnostic biopsies, 54 (77%) were malignant cases, 94% of which were renal cell carcinoma (RCC). Of the 12 nondiagnostic cases, the final diagnosis was RCC in 4 cases and angiomyolipoma in one case; seven of the nondiagnostic cases were lost to follow-up. A weak association (p = 0.04) was found between the number of needle passes and the biopsy outcome. None of the remaining collected RMB characteristics showed a significant correlation with a diagnostic or nondiagnostic RMB. Six patients (7%) experienced complications. Ultrasound-guided renal mass biopsy is a safe and effective method for the diagnosis of renal masses with a low rate of nondiagnostic outcomes. A nondiagnostic biopsy should not be treated as a surrogate for a diagnosis since a significant number of patients with nondiagnostic biopsies have subsequently been shown to have renal malignancies. Repeat biopsy should be considered in such cases.

  3. Efficacy of ultrasound-guided percutaneous needle treatment of calcific tendinitis.

    PubMed

    Vignesh, K Nithin; McDowall, Adam; Simunovic, Nicole; Bhandari, Mohit; Choudur, Hema N

    2015-01-01

    The purpose of this study was to conduct a systematic review of the efficacy of ultrasound-guided needle lavage in treating calcific tendinitis. Two independent assessors searched medical databases and screened studies for eligibility. Eleven articles were included. Heterogeneity among included studies precluded meta-analysis. Results of randomized controlled trials suggested no difference in pain relief between needle lavage and other interventions, but the studies were of low quality. Additional high-quality evidence is required to determine the relative efficacy of ultrasound-guided needle lavage in the management of calcific tendinitis of the rotator cuff.

  4. Optimizing modality selection for image-guided procedures: an analysis of the challenges to ultrasound guidance.

    PubMed

    Beland, Michael D; Sternick, Laura A; Baird, Grayson L; Dupuy, Damian E; Cronan, John J; Mayo-Smith, William W

    2016-04-01

    Selection of the most appropriate modality for image guidance is essential for procedural success. We identified specific factors contributing to failure of ultrasound-guided procedures that were subsequently performed using CT guidance. This single-center, retrospective study included 164 patients who underwent a CT-guided biopsy, aspiration/drainage, or ablation after initially having the same procedure attempted unsuccessfully with ultrasound guidance. Review of the procedure images, reports, biopsy results, and clinical follow-up was performed and the reasons for inability to perform the procedure with ultrasound guidance were recorded. Patient cross-sectional area and depth to target were calculated. Differences in area and depth were compared using general linear modeling. Depth as a predictor of an unfavorable body habitus designation was modeled using logistic regression. US guidance was successful in the vast majority of cases (97%). Of the 164 procedures, there were 92 (56%) biopsies, 63 (38%) aspirations/drainages, and 9 (5%) ablations. The most common reason for procedure failure was poor acoustic window (83/164, 51%). Other reasons included target lesion being poorly discerned from adjacent tissue (61/164, 37%), adjacent bowel gas (34/164, 21%), body habitus (27/164, 16%), and gas-containing collection (22/164, 13%). Within the biopsy subgroup, patients for whom body habitus was a limiting factor were found to have on average a larger cross-sectional area and lesion depth relative to patients whose body habitus was not a complicating factor (p < 0.0001 and p = 0.0009). Poor acoustic window was the most common reason for procedural failure with ultrasound guidance. In addition, as lesion depth increased, the odds that body habitus would limit the procedure also increased. If preliminary imaging suggests a limited sonographic window, particularly for deeper lesions, proceeding directly to CT guidance should be considered.

  5. Mixed reality ultrasound guidance system: a case study in system development and a cautionary tale.

    PubMed

    Ameri, Golafsoun; Baxter, John S H; Bainbridge, Daniel; Peters, Terry M; Chen, Elvis C S

    2018-04-01

    Real-time ultrasound has become a crucial aspect of several image-guided interventions. One of the main constraints of such an approach is the difficulty in interpretability of the limited field of view of the image, a problem that has recently been addressed using mixed reality, such as augmented reality and augmented virtuality. The growing popularity and maturity of mixed reality has led to a series of informal guidelines to direct development of new systems and to facilitate regulatory approval. However, the goals of mixed reality image guidance systems and the guidelines for their development have not been thoroughly discussed. The purpose of this paper is to identify and critically examine development guidelines in the context of a mixed reality ultrasound guidance system through a case study. A mixed reality ultrasound guidance system tailored to central line insertions was developed in close collaboration with an expert user. This system outperformed ultrasound-only guidance in a novice user study and has obtained clearance for clinical use in humans. A phantom study with 25 experienced physicians was carried out to compare the performance of the mixed reality ultrasound system against conventional ultrasound-only guidance. Despite the previous promising results, there was no statistically significant difference between the two systems. Guidelines for developing mixed reality image guidance systems cannot be applied indiscriminately. Each design decision, no matter how well justified, should be the subject of scientific and technical investigation. Iterative and small-scale evaluation can readily unearth issues and previously unknown or implicit system requirements. We recommend a wary eye in development of mixed reality ultrasound image guidance systems emphasizing small-scale iterative evaluation alongside system development. Ultimately, we recommend that the image-guided intervention community furthers and deepens this discussion into best practices in developing image-guided interventions.

  6. Endoscopic ultrasound-guided placement of plastic vs. biflanged metal stents for therapy of walled-off necrosis: a retrospective single-center series.

    PubMed

    Mukai, Shuntaro; Itoi, Takao; Baron, Todd H; Sofuni, Atsushi; Itokawa, Fumihide; Kurihara, Toshio; Tsuchiya, Takayoshi; Ishii, Kentaro; Tsuji, Shujiro; Ikeuchi, Nobuhito; Tanaka, Reina; Umeda, Junko; Tonozuka, Ryosuke; Honjo, Mitsuyoshi; Gotoda, Takuji; Moriyasu, Fuminori; Yasuda, Ichiro

    2015-01-01

    Recently, a novel fully covered and biflanged metal stent (BFMS)dedicated to the drainage of walled-off necrosis(WON) was developed. The aim of this study was to retrospectively evaluate the safety, efficacy, and cost performance of drainage of WON using the novel BFMS compared with a traditional plastic stent. A total of 70 patients with symptomatic WON were treated under endoscopic ultrasound (EUS) guidance. Initial drainage was conducted using the single gateway technique with placement of one or more plastic stents or a single BFMS.If drainage was unsuccessful,direct endoscopic necrosectomy (DEN)was performed. There were no statistically significant differences in rates of technical success, clinical success,and adverse events between plastics stents and BFMS, despite the size of WON in the BFMS group being significantly larger than that in the plastic stent group (105.6 vs. 77.1 mm; P=0.003).The mean procedure times for the first EUS-guided drainage and for re-intervention were significantly shorter in the BFMS group than in the plastic stent group (28.8±7.1 vs. 42.6±14.2, respectively,for drainage, P<0.001; and 34.9±8.5 vs.41.8±7.6, respectively, for re-intervention, P<0.001). There was no statistically significant difference in the total cost between plastic stent and BFMS use in the treatment of WON ($5352vs. $6274; P=0.25). Plastic stents and BFMS were safe and effective for the treatment of WON. In particular,BFMS placement appeared to be preferable for initial EUS-guided drainage and additional reintervention(e.g. DEN) as it reduced the procedure time. Prospective randomized controlled trials are warranted.

  7. Management of Dupuytren contracture with ultrasound-guided lidocaine injection and needle aponeurotomy coupled with osteopathic manipulative treatment.

    PubMed

    Sampson, Steven; Meng, Michael; Schulte, Adam; Trainor, Drew; Montenegro, Roberto; Aufiero, Danielle

    2011-02-01

    Dupuytren contracture is a debilitating disease that characteristically presents as a firm nodularity on the palmar surface of the hand with coalescing cords of soft tissue on the webs and digits. With few nonsurgical modalities providing clinical benefits, open surgical procedures are the standard of care for patients with this condition. However, recent studies have associated surgical intervention with many complications, necessitating further exploration of nonsurgical treatment options. We describe the case of a 64-year-old woman who presented with decreased extension of the fourth and fifth digits on the upper extremities bilaterally; previous conservative treatment regimens had been unsuccessful. After a diagnostic ultrasound, the patient was diagnosed as having Dupuytren contracture and underwent 5 treatments consisting of ultrasound-guided dry-needle aponeurotomy, lidocaine injections, and osteopathic manipulative treatment. During the fifth treatment session, the patient experienced dramatic relief of her symptoms after a palpable release during the manual manipulation portion of her therapeutic regimen. At 2-week follow-up, the patient was symptom-free. Based on this desirable outcome, the authors suggest future research be directed at minimally invasive therapeutic options in the management of Dupuytren contracture.

  8. Optimizing MR imaging-guided navigation for focused ultrasound interventions in the brain

    NASA Astrophysics Data System (ADS)

    Werner, B.; Martin, E.; Bauer, R.; O'Gorman, R.

    2017-03-01

    MR imaging during transcranial MR imaging-guided Focused Ultrasound surgery (tcMRIgFUS) is challenging due to the complex ultrasound transducer setup and the water bolus used for acoustic coupling. Achievable image quality in the tcMRIgFUS setup using the standard body coil is significantly inferior to current neuroradiologic standards. As a consequence, MR image guidance for precise navigation in functional neurosurgical interventions using tcMRIgFUS is basically limited to the acquisition of MR coordinates of salient landmarks such as the anterior and posterior commissure for aligning a stereotactic atlas. Here, we show how improved MR image quality provided by a custom built MR coil and optimized MR imaging sequences can support imaging-guided navigation for functional tcMRIgFUS neurosurgery by visualizing anatomical landmarks that can be integrated into the navigation process to accommodate for patient specific anatomy.

  9. Focused Ultrasound Surgery in Oncology: Overview and Principles

    PubMed Central

    McDannold, Nathan J.; Hynynen, Kullervo; Jolesz, Ferenc A.

    2011-01-01

    Focused ultrasound surgery (FUS) is a noninvasive image-guided therapy and an alternative to surgical interventions. It presents an opportunity to revolutionize cancer therapy and to affect or change drug delivery of therapeutic agents in new focally targeted ways. In this article the background, principles, technical devices, and clinical cancer applications of image-guided FUS are reviewed. © RSNA, 2011 PMID:21436096

  10. Innovations and techniques for balloon-enteroscope-assisted endoscopic retrograde cholangiopancreatography in patients with altered gastrointestinal anatomy

    PubMed Central

    Yamauchi, Hiroshi; Kida, Mitsuhiro; Imaizumi, Hiroshi; Okuwaki, Kosuke; Miyazawa, Shiro; Iwai, Tomohisa; Koizumi, Wasaburo

    2015-01-01

    Endoscopic retrograde cholangiopancreatography (ERCP) remains challenging in patients who have undergone surgical reconstruction of the intestine. Recently, many studies have reported that balloon-enteroscope-assisted ERCP (BEA-ERCP) is a safe and effective procedure. However, further improvements in outcomes and the development of simplified procedures are required. Percutaneous treatment, Laparoscopy-assisted ERCP, endoscopic ultrasound-guided anterograde intervention, and open surgery are effective treatments. However, treatment should be noninvasive, effective, and safe. We believe that these procedures should be performed only in difficult-to-treat patients because of many potential complications. BEA-ERCP still requires high expertise-level techniques and is far from a routinely performed procedure. Various techniques have been proposed to facilitate scope insertion (insertion with percutaneous transhepatic biliary drainage (PTBD) rendezvous technique, Short type single-balloon enteroscopes with passive bending section, Intraluminal injection of indigo carmine, CO2 inflation guidance), cannulation (PTBD or percutaneous transgallbladder drainage rendezvous technique, Dilation using screw drill, Rendezvous technique combining DBE with a cholangioscope, endoscopic ultrasound-guided rendezvous technique), and treatment (overtube-assisted technique, Short type balloon enteroscopes) during BEA-ERCP. The use of these techniques may allow treatment to be performed by BEA-ERCP in many patients. A standard procedure for ERCP yet to be established for patients with a reconstructed intestine. At present, BEA-ERCP is considered the safest and most effective procedure and is therefore likely to be recommended as first-line treatment. In this article, we discuss the current status of BEA-ERCP in patients with surgically altered gastrointestinal anatomy. PMID:26074685

  11. MRI-guided focused ultrasound surgery in musculoskeletal diseases: the hot topics

    PubMed Central

    Napoli, Alessandro; Sacconi, Beatrice; Battista, Giuseppe; Guglielmi, Giuseppe; Catalano, Carlo; Albisinni, Ugo

    2016-01-01

    MRI-guided focused ultrasound surgery (MRgFUS) is a minimally invasive treatment guided by the most sophisticated imaging tool available in today's clinical practice. Both the imaging and therapeutic sides of the equipment are based on non-ionizing energy. This technique is a very promising option as potential treatment for several pathologies, including musculoskeletal (MSK) disorders. Apart from clinical applications, MRgFUS technology is the result of long, heavy and cumulative efforts exploring the effects of ultrasound on biological tissues and function, the generation of focused ultrasound and treatment monitoring by MRI. The aim of this article is to give an updated overview on a “new” interventional technique and on its applications for MSK and allied sciences. PMID:26607640

  12. Ultrasound imaging in medical student education: Impact on learning anatomy and physical diagnosis.

    PubMed

    So, Sokpoleak; Patel, Rita M; Orebaugh, Steven L

    2017-03-01

    Ultrasound use has expanded dramatically among the medical specialties for diagnostic and interventional purposes, due to its affordability, portability, and practicality. This imaging modality, which permits real-time visualization of anatomic structures and relationships in vivo, holds potential for pre-clinical instruction of students in anatomy and physical diagnosis, as well as providing a bridge to the eventual use of bedside ultrasound by clinicians to assess patients and guide invasive procedures. In many studies, but not all, improved understanding of anatomy has been demonstrated, and in others, improved accuracy in selected aspects of physical diagnosis is evident. Most students have expressed a highly favorable impression of this technology for anatomy education when surveyed. Logistic issues or obstacles to the integration of ultrasound imaging into anatomy teaching appear to be readily overcome. The enthusiasm of students and anatomists for teaching with ultrasound has led to widespread implementation of ultrasound-based teaching initiatives in medical schools the world over, including some with integration throughout the entire curriculum; a trend that likely will continue to grow. Anat Sci Educ 10: 176-189. © 2016 American Association of Anatomists. © 2016 American Association of Anatomists.

  13. Biopsy of Liver Target Lesions under Contrast-Enhanced Ultrasound Guidance - A Multi-Center Study.

    PubMed

    Francica, Giampiero; Meloni, Maria Franca; de Sio, Ilario; Terracciano, Fulvia; Caturelli, Eugenio; Riccardi, Laura; Roselli, Paola; Iadevaia, Maddalena Diana; Scaglione, Mariano; Lenna, Giovanni; Chiang, Jason; Pompili, Maurizio

    2017-12-12

    Purpose  To retrospectively characterize the prevalence and impact of contrast-enhanced ultrasound (CEUS) as a guidance technique for the biopsy of liver target lesions (LTLs) at six interventional ultrasound centers. Materials and Methods  The six participating centers retrospectively selected all patients in whom biopsy needles were positioned in LTLs during CEUS. The prevalence of CEUS-guided biopsies at each center between 2005 and 2016, contrast agent consumption, procedure indications, diagnostic yield and complications were assessed. Informed consent was obtained for all patients. Results  CEUS-guided biopsy of LTLs was carried out in 103 patients (68 M/35 F, median age: 69 yrs) with 103 liver target lesions (median size: 20 mm) using cutting needles (18 - 20 g) in 94 cases (91.2 %). CEUS-guided biopsy represented 2.6 % (range: 0.8 - 7.7 %) of 3818 biopsies on LTLs carried out at the participating centers. Indications to CEUS-guided biopsy were: a target lesion not visible on non-enhanced US (27.2 %), improvement of conspicuity of the target (33 %), choice of non-necrotic area inside the target (39.8 %). 26 patients (25.2 %) had a previously non-diagnostic cyto-histological exam. The diagnostic accuracy of the technique was 99 %. No major complications followed infusion of contrast agent or biopsy performance. Conclusion  The indications for CEUS-guided biopsy for LTLs are limited, but CEUS can be useful in challenging clinical scenarios, e. g. poorly visualized or invisible lesions or sampling of non-necrotic areas in the target lesions. There is also a potential advantage in using CEUS to guide repeat biopsies after unsuccessful sampling performed using the standard ultrasound technique. © Georg Thieme Verlag KG Stuttgart · New York.

  14. Randomized comparison of three transducer orientation approaches for ultrasound guided internal jugular venous cannulation.

    PubMed

    Batllori, M; Urra, M; Uriarte, E; Romero, C; Pueyo, J; López-Olaondo, L; Cambra, K; Ibáñez, B

    2016-03-01

    Ultrasound-guided internal jugular venous access increases the rate of successful cannulation and reduces the incidence of complications, compared with the landmark technique. Three transducer orientation approaches have been proposed for this procedure: short-axis (SAX), long-axis (LAX) and oblique-axis (OAX). Our goal was to assess and compare the performance of these approaches. A prospective randomized clinical trial was conducted in one teaching hospital. Patients aged 18 yr or above, who were undergoing ultrasound-guided internal jugular cannulation, were randomly assigned to one of three intervention groups: SAX, LAX and OAX group. The main outcome measure was successful cannulation on first needle pass. Incidence of mechanical complications was also registered. Restricted randomization was computer-generated. In total, 220 patients were analysed (SAX n=73, LAX n=75, OAX n=72). Cannulation was successful on first needle pass in 51 (69.9%) SAX patients, 39 (52%) LAX patients and 53 (73.6%) OAX patients. First needle pass failure was higher in the LAX group than in the OAX group (adjusted OR 3.7, 95% CI 1.71-8.0, P=0.002). A higher mechanical complication rate was observed in the SAX group (15.1%) than in the OAX (6.9%) and LAX (4%) groups (P=0.047). As OAX showed a higher first needle pass success rate than LAX and a lower mechanical complications rate than SAX, we recommend it as the standard approach when performing ultrasound-guided internal jugular venous access. Further clinical studies are needed to confirm this conclusion. NCT 01966354. © The Author 2015. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  15. Interventional radiology virtual simulator for liver biopsy.

    PubMed

    Villard, P F; Vidal, F P; ap Cenydd, L; Holbrey, R; Pisharody, S; Johnson, S; Bulpitt, A; John, N W; Bello, F; Gould, D

    2014-03-01

    Training in Interventional Radiology currently uses the apprenticeship model, where clinical and technical skills of invasive procedures are learnt during practice in patients. This apprenticeship training method is increasingly limited by regulatory restrictions on working hours, concerns over patient risk through trainees' inexperience and the variable exposure to case mix and emergencies during training. To address this, we have developed a computer-based simulation of visceral needle puncture procedures. A real-time framework has been built that includes: segmentation, physically based modelling, haptics rendering, pseudo-ultrasound generation and the concept of a physical mannequin. It is the result of a close collaboration between different universities, involving computer scientists, clinicians, clinical engineers and occupational psychologists. The technical implementation of the framework is a robust and real-time simulation environment combining a physical platform and an immersive computerized virtual environment. The face, content and construct validation have been previously assessed, showing the reliability and effectiveness of this framework, as well as its potential for teaching visceral needle puncture. A simulator for ultrasound-guided liver biopsy has been developed. It includes functionalities and metrics extracted from cognitive task analysis. This framework can be useful during training, particularly given the known difficulties in gaining significant practice of core skills in patients.

  16. Malignant biliary disease: percutaneous interventions.

    PubMed

    Morgan, R A; Adam, A N

    2001-09-01

    Interventional radiologists have an important role in the management of patients with malignant biliary obstruction. This article describes the techniques for percutaneous biliary drainage, insertion of biliary endoprostheses, and the management of occluded biliary endoprostheses. Most procedures are performed by using fluoroscopic guidance alone. Ultrasound is also a useful modality for guiding biliary drainage, particularly drainage of the left biliary ducts. Patients should be treated by internal drainage if possible. Metallic endoprostheses can be inserted at the time of the initial biliary drainage procedure. Plastic tubes should be inserted a few days after biliary drainage because of their relatively large size compared with metallic stents. Occluded plastic stents should be replaced. Blocked metallic stents should be treated either by placement of additional overlapping metallic stents or by placement of plastic stents within the metallic stent lumen. Copyright 2001 by W.B. Saunders Company

  17. Ultrasound-Guided Core-Needle Versus Vacuum-Assisted Breast Biopsy: A Cost Analysis Based on the American Society of Breast Surgeons' Mastery of Breast Surgery Registry.

    PubMed

    Grady, Ian; Vasquez, Tony; Tawfik, Sara; Grady, Sean

    2017-03-01

    To evaluate the cost-efficacy of vacuum-assisted ultrasound-guided breast biopsy instruments compared to ultrasound-guided 14-gauge spring-loaded core-needle biopsy. The American Society of Breast Surgeons' Mastery of Breast Surgery Registry was reviewed. Biopsy findings, any rebiopsy, and the instrument used were abstracted for 31,451 ultrasound-guided biopsy procedures performed between 2001 and July 2014. Rates of cancer diagnosis and rebiopsy were calculated for each instrument. A linear mathematical model was developed to calculate total cost per cancer diagnosis, including procedural costs and the costs of any additional surgical rebiopsy procedures. Mean cost per cancer diagnosis with confidence limits was then determined for 14-gauge spring-loaded core-needle biopsy and 14 different vacuum-assisted instruments. For 14-gauge spring-loaded core-needle biopsy, mean cost per cancer diagnosis was $4346 (4327-$4366). For the vacuum-assisted instruments, mean cost per cancer diagnosis ranged from a low of $3742 ($3732-$3752) to a high of $4779 ($4750-$4809). Vacuum-assisted instruments overall were more cost-effective than core with a mean cost per cancer diagnosis of $4052 ($4038-$4067) (p < 0.05). Tethered vacuum-assisted instruments performed best with a mean cost per cancer diagnosis of $3978 ($3964-$3991) (p < 0.05). Nontethered devices had a mean cost per cancer diagnosis of $4369 ($4350-$4388), a result no better than core (p < 0.05). Ultrasound-guided vacuum-assisted breast biopsy had a lower mean cost per cancer diagnosis than 14-gauge spring-loaded core-needle biopsy. This advantage was only seen in tethered vacuum-assisted instruments. Within device families, larger instruments tended to outperform smaller instruments.

  18. Advanced Endoscopic Navigation: Surgical Big Data, Methodology, and Applications.

    PubMed

    Luo, Xiongbiao; Mori, Kensaku; Peters, Terry M

    2018-06-04

    Interventional endoscopy (e.g., bronchoscopy, colonoscopy, laparoscopy, cystoscopy) is a widely performed procedure that involves either diagnosis of suspicious lesions or guidance for minimally invasive surgery in a variety of organs within the body cavity. Endoscopy may also be used to guide the introduction of certain items (e.g., stents) into the body. Endoscopic navigation systems seek to integrate big data with multimodal information (e.g., computed tomography, magnetic resonance images, endoscopic video sequences, ultrasound images, external trackers) relative to the patient's anatomy, control the movement of medical endoscopes and surgical tools, and guide the surgeon's actions during endoscopic interventions. Nevertheless, it remains challenging to realize the next generation of context-aware navigated endoscopy. This review presents a broad survey of various aspects of endoscopic navigation, particularly with respect to the development of endoscopic navigation techniques. First, we investigate big data with multimodal information involved in endoscopic navigation. Next, we focus on numerous methodologies used for endoscopic navigation. We then review different endoscopic procedures in clinical applications. Finally, we discuss novel techniques and promising directions for the development of endoscopic navigation.

  19. The challenging image-guided abdominal mass biopsy: established and emerging techniques 'if you can see it, you can biopsy it'.

    PubMed

    Sainani, Nisha I; Arellano, Ronald S; Shyn, Paul B; Gervais, Debra A; Mueller, Peter R; Silverman, Stuart G

    2013-08-01

    Image-guided percutaneous biopsy of abdominal masses is among the most commonly performed procedures in interventional radiology. While most abdominal masses are readily amenable to percutaneous biopsy, some may be technically challenging for a number of reasons. Low lesion conspicuity, small size, overlying or intervening structures, motion, such as that due to respiration, are some of the factors that can influence the ability and ultimately the success of an abdominal biopsy. Various techniques or technologies, such as choice of imaging modality, use of intravenous contrast and anatomic landmarks, patient positioning, organ displacement or trans-organ approach, angling CT gantry, triangulation method, real-time guidance with CT fluoroscopy or ultrasound, sedation or breath-hold, pre-procedural image fusion, electromagnetic tracking, and others, when used singularly or in combination, can overcome these challenges to facilitate needle placement in abdominal masses that otherwise would be considered not amenable to percutaneous biopsy. Familiarity and awareness of these techniques allows the interventional radiologist to expand the use of percutaneous biopsy in clinical practice, and help choose the most appropriate technique for a particular patient.

  20. The Second American Society of Regional Anesthesia and Pain Medicine Evidence-Based Medicine Assessment of Ultrasound-Guided Regional Anesthesia: Executive Summary.

    PubMed

    Neal, Joseph M; Brull, Richard; Horn, Jean-Louis; Liu, Spencer S; McCartney, Colin J L; Perlas, Anahi; Salinas, Francis V; Tsui, Ban Chi-Ho

    2016-01-01

    In 2009 and again in 2012, the American Society of Regional Anesthesia and Pain Medicine assembled an expert panel to assess the evidence basis for ultrasound guidance as a nerve localization tool for regional anesthesia. The 2012 panel reviewed evidence from the first advisory but focused primarily on new information that had emerged since 2009. A new section was added regarding the accuracy and reliability of ultrasound for determining needle-to-nerve proximity. Jadad scores are used to rank study quality. Grades of recommendations consistent with their level of evidence are provided. The panel offers recommendations based on synthesis and analysis of literature related to (1) the technical capabilities of ultrasound equipment and its operators, (2) comparison of ultrasound to other methods of nerve localization with regard to block characteristics, (3) comparison of block techniques where ultrasound is the sole nerve localization modality, and (4) major complications. Assessment of evidence strength and recommendations are made for upper- and lower-extremity, truncal, neuraxial, and pediatric blocks. Scientific evidence from the past 5 years has clarified and strengthened our understanding of ultrasound-guided regional anesthesia as a nerve localization tool. High-level evidence supports ultrasound guidance contributing to superior characteristics with selected blocks, although absolute differences with the comparator technique are often relatively small (especially for upper-extremity blocks). The clinical meaningfulness of these differences is likely of variable importance to individual practitioners. The use of ultrasound significantly reduces the risk of local anesthetic systemic toxicity as well as the incidence and intensity of hemidiaphragmatic paresis, but has no significant effect on the incidence of postoperative neurologic symptoms. WHAT'S NEW IN THIS UPDATE?: This evidence-based assessment of ultrasound-guided regional anesthesia reviews findings from our 2010 publication and focuses on new meta-analyses, randomized controlled trials, and large case series published since 2009. New to this exercise is an in-depth analysis of the accuracy and reliability of ultrasound guidance for identifying needle-to-nerve relationships. This version no longer addresses ultrasound for interventional pain medicine procedures, because the growth of that field demands separate consideration. Since our 2010 publication, new information has either supported or strengthened our original conclusions. There is no evidence that ultrasound is inferior to alternative nerve localization methods.

  1. Ultrasound-Guided Percutaneous Drainage of Neonatal Pyometrocolpos Under Local Anesthesia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Algin, Oktay, E-mail: droktayalgin@gmail.com; Erdogan, Cuneyt; Kilic, Nizamettin

    2011-02-15

    Hydrometrocolpos is an uncommon congenital disorder with cystic dilatation of the vagina and uterus that occurs as a result of accumulated secretions from the reproductive tract due to distal genital tract obstruction. Secondary infection may also occur, resulting in pyometrocolpos, a potentially lethal disease. Immediate drainage of the cystic mass in patients determined to have pyometrocolpos is required to prevent or treat uropathy and septicemia until definitive corrective surgery can be performed. We report an unusual cause of obstructive uropathy in three infants: pyometrocolpos due to lower genital tract atresia. Ultrasound-guided percutaneous drainage of the pyometrocolpos resulted in dramatically improvedmore » clinical and laboratory findings in these patients. Ultrasound-guided percutaneous drainage under local anesthesia is a simple, minimally invasive, safe, and effective procedure that facilitates later successful corrective surgery and avoids the need for more complex drainage procedures.« less

  2. Internal Medicine Point-of-Care Ultrasound Curriculum: Consensus Recommendations from the Canadian Internal Medicine Ultrasound (CIMUS) Group.

    PubMed

    Ma, Irene W Y; Arishenkoff, Shane; Wiseman, Jeffrey; Desy, Janeve; Ailon, Jonathan; Martin, Leslie; Otremba, Mirek; Halman, Samantha; Willemot, Patrick; Blouw, Marcus

    2017-09-01

    Bedside point-of-care ultrasound (POCUS) is increasingly used to assess medical patients. At present, no consensus exists for what POCUS curriculum is appropriate for internal medicine residency training programs. This document details the consensus-based recommendations by the Canadian Internal Medicine Ultrasound (CIMUS) group, comprising 39 members, representing 14 institutions across Canada. Guiding principles for selecting curricular content were determined a priori. Consensus was defined as agreement by at least 80% of the members on POCUS applications deemed appropriate for teaching and assessment of trainees in the core (internal medicine postgraduate years [PGY] 1-3) and expanded (general internal medicine PGY 4-5) training programs. We recommend four POCUS applications for the core PGY 1-3 curriculum (inferior vena cava, lung B lines, pleural effusion, and abdominal free fluid) and three ultrasound-guided procedures (central venous catheterization, thoracentesis, and paracentesis). For the expanded PGY 4-5 curriculum, we recommend an additional seven applications (internal jugular vein, lung consolidation, pneumothorax, knee effusion, gross left ventricular systolic function, pericardial effusion, and right ventricular strain) and four ultrasound-guided procedures (knee arthrocentesis, arterial line insertion, arterial blood gas sampling, and peripheral venous catheterization). These recommendations will provide a framework for training programs at a national level.

  3. Back-to-back optical coherence tomography-ultrasound probe for co-registered three-dimensional intravascular imaging with real-time display

    NASA Astrophysics Data System (ADS)

    Li, Jiawen; Ma, Teng; Jing, Joseph; Zhang, Jun; Patel, Pranav M.; Shung, K. Kirk; Zhou, Qifa; Chen, Zhongping

    2014-03-01

    We have developed a novel integrated optical coherence tomography (OCT)-intravascular ultrasound (IVUS) probe, with a 1.5 mm-long rigid-part and 0.9 mm outer diameter, for real-time intracoronary imaging of atherosclerotic plaques and guiding interventional procedures. By placing the OCT ball lens and IVUS 45MHz single element transducer back-to-back at the same axial position, this probe can provide automatically co-registered, co-axial OCT-IVUS imaging. To demonstrate its capability, 3D OCT-IVUS imaging of a pig's coronary artery in real-time displayed in polar coordinates, as well as images of two major types of advanced plaques in human cadaver coronary segments, was obtained using this probe and our upgraded system. Histology validation is also presented.

  4. Ethanol sclerotherapy of ovarian endometrioma: a safe and effective minimal invasive procedure. Preliminary results.

    PubMed

    García-Tejedor, Amparo; Castellarnau, Marta; Ponce, Jordi; Fernández, Ma Eulalia; Burdio, Fernando

    2015-04-01

    To study if ultrasound-guided aspiration with ethanol sclerosis is a safe and effective treatment for endometriomas. We conducted a prospective study of 25 women with 27 endometriomas (two bilateral) measuring 4-10cm in diameter with no suspected malignancy, who underwent ultrasound-guided aspiration and ethanol sclerosis between August 2010 and July 2014. Patients were followed up by ultrasound at 6, 12, 24, and 36 months to identify rates of complication and recurrence. Clinical characteristics of the patients (age, history of infertility, previous surgery, and abdominal pain), the cysts (location, diameter, and volume) and the procedure (duration and complications) were recorded. Kaplan-Meier survival curves were used to analyze the recurrence rates by SPSS statistical software. The recurrence rate after sclerosis was 12%. The mean length of follow-up was 17 (SD 9.9) months. Although no major procedure-related complications were recorded, minor complications included three cases of low abdominal pain during the procedure (10.7%) and two cases of abdominal ethanol extravasation (7.1%). Ultrasound-guided aspiration and ethanol sclerotherapy are a safe and effective treatment for endometriomas measuring 4-10cm in diameter with no evidence of malignancy. This conservative treatment could possibly achieve a symptomatic cure while preserving healthy ovarian tissue, thereby improving fertility outcomes and avoiding early menopause. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  5. Alternative therapies in management of leiomyomas.

    PubMed

    Patel, Amrita; Malik, Minnie; Britten, Joy; Cox, Jeris; Catherino, William H

    2014-09-01

    Leiomyomas are benign soft-tissue neoplasms that arise from smooth muscle. Relief of symptoms (abnormal uterine bleeding, pain, pressure) is the major goal in management of women with significant symptoms. For symptomatic myomas, hysterectomy is a definitive solution; however, there are emerging less-invasive options. Magnetic resonance imaging-guided focused ultrasound surgery, cryomyolysis, and temporary occlusion of the uterine arteries are treatment options that are minimally invasive interventions with the benefit of preserving the uterus. This review summarizes procedure techniques, eligibility, complications, and outcomes of these alternate therapies. Published by Elsevier Inc.

  6. Comparison between ultrasound-guided compression and para-aneurysmal saline injection in the treatment of postcatheterization femoral artery pseudoaneurysms.

    PubMed

    ElMahdy, Mahmoud Farouk; Kassem, Hussien Heshmat; Ewis, Essam Baligh; Mahdy, Soliman Gharieb

    2014-03-01

    Management of postcatheterization femoral artery pseudoaneurysm (FAP) is problematic. Ultrasound-guided compression (UGC) is painful and cumbersome. Thrombin injection is costly and may cause thromboembolism. Ultrasound-guided para-aneurysmal saline injection (PASI) has been described but was never compared against other treatment methods of FAP. We aimed at comparing the success rate and complications of PASI versus UGC. We randomly assigned 80 patients with postcatheterization FAPs to either UGC (40 patients) or PASI (40 patients). We compared the 2 procedures regarding successful obliteration of the FAP, incidence of vasovagal attacks, procedure time, discontinuation of antiplatelet and/or anticoagulants, and the Doppler waveform in the ipsilateral pedal arteries at the end of the procedure. There was no significant difference between patients in both groups regarding clinical and vascular duplex data. The mean durations of UGC and PASI procedures were 58.14 ± 28.45 and 30.33 ± 8.56 minutes, respectively (p = 0.045). Vasovagal attacks were reported in 10 (25%) and 2 patients (5%) treated with UGC and PASI, respectively (p = 0.05). All patients in both groups had triphasic Doppler waveform in the infrapopliteal arteries before and after the procedure. The primary and final success rates were 75%, 92.5%, 87.5%, and 95% for UGC and PASI, respectively (p = 0.43). In successfully treated patients, there was no reperfusion of the FAP in the follow-up studies (days 1 and 7) in both groups. In conclusion, ultrasound-guided PASI is an effective method for the treatment of FAP. Compared with UGC, PASI is faster, less likely to cause vasovagal reactions, and can be more convenient to patients and physicians. Copyright © 2014 Elsevier Inc. All rights reserved.

  7. Musculoskeletal ultrasound: how to treat calcific tendinitis of the rotator cuff by ultrasound-guided single-needle lavage technique.

    PubMed

    Lee, Kenneth S; Rosas, Humberto G

    2010-09-01

    The purpose of this video article is to illustrate the ultrasound appearance of calcium deposition in the rotator cuff and provide a detailed step-by-step protocol for performing the ultrasound-guided single-needle lavage technique for the treatment of calcific tendinitis with emphasis on patient positioning, necessary supplies, real-time lavage technique, and steroid injection into the subacromial subdeltoid bursa. Musculoskeletal ultrasound is well established as a safe, cost-effective imaging tool in diagnosing and treating common musculoskeletal disorders. Calcific tendinitis of the rotator cuff is a common disabling cause of shoulder pain. Although most cases are self-limiting, a subset of patients is refractory to conservative therapy and requires treatment intervention. Ultrasound-guided lavage is an effective and safe minimally-invasive treatment not readily offered in the United States as an alternative to surgery, perhaps because of the limited prevalence of musculoskeletal ultrasound programs and limited training. On completion of this video article, the participant should be able to develop an appropriate diagnostic and therapeutic algorithm for the treatment of calcific tendinitis of the rotator cuff using ultrasound.

  8. Interventional multi-spectral photoacoustic imaging in laparoscopic surgery

    NASA Astrophysics Data System (ADS)

    Hill, Emma R.; Xia, Wenfeng; Nikitichev, Daniil I.; Gurusamy, Kurinchi; Beard, Paul C.; Hawkes, David J.; Davidson, Brian R.; Desjardins, Adrien E.

    2016-03-01

    Laparoscopic procedures can be an attractive treatment option for liver resection, with a shortened hospital stay and reduced morbidity compared to open surgery. One of the central challenges of this technique is visualisation of concealed structures within the liver, particularly the vasculature and tumourous tissue. As photoacoustic (PA) imaging can provide contrast for haemoglobin in real time, it may be well suited to guiding laparoscopic procedures in order to avoid inadvertent trauma to vascular structures. In this study, a clinical laparoscopic ultrasound probe was used to receive ultrasound for PA imaging and to obtain co-registered B-mode ultrasound (US) images. Pulsed excitation light was delivered to the tissue via a fibre bundle in dark-field mode. Monte Carlo simulations were performed to optimise the light delivery geometry for imaging targets at depths of 1 cm, 2 cm and 3 cm, and 3D-printed mounts were used to position the fibre bundle relative to the transducer according to the simulation results. The performance of the photoacoustic laparoscope system was evaluated with phantoms and tissue models. The clinical potential of hybrid PA/US imaging to improve the guidance of laparoscopic surgery is discussed.

  9. Ultrasound-Guided Angioplasty of Dysfunctional Vascular Access for Haemodialysis. The Pros and Cons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    García-Medina, J., E-mail: josegmedina57@gmail.com; García-Alfonso, J. J., E-mail: juanjozarandieta@gmail.com

    PurposeTo describe the benefits and the disadvantages of angioplasty in dialysis fistulas using only ultrasound guidance.Materials and MethodsThis is a prospective study in 132 failing or non-maturing arteriovenous accesses that underwent 189 ultrasound-guided balloon angioplasties. The technical success was defined as non-use of X-ray fluoroscopy during the procedure.Results127 procedures (67%) were successfully completed without fluoroscopy. Most failures were due to difficulty to traverse aneurismal segments, as well as anastomotic stenoses. Including initial failures, the primary patency rates at 6, 12 months and 2 years were 75 ± 3, 41 ± 3 and 14 ± 2%, respectively.ConclusionEndovascular repair of the dysfunctional vascular access for haemodialysis under ultrasound guidance ismore » feasible and safe in roughly two-thirds of cases.« less

  10. Derivation of a Performance Checklist for Ultrasound-Guided Arthrocentesis Using the Modified Delphi Method.

    PubMed

    Kunz, Derek; Pariyadath, Manoj; Wittler, Mary; Askew, Kim; Manthey, David; Hartman, Nicholas

    2017-06-01

    Arthrocentesis is an important skill for physicians in multiple specialties. Recent studies indicate a superior safety and performance profile for this procedure using ultrasound guidance for needle placement, and improving quality of care requires a valid measurement of competency using this modality. We endeavored to create a validated tool to assess the performance of this procedure using the modified Delphi technique and experts in multiple disciplines across the United States. We derived a 22-item checklist designed to assess competency for the completion of ultrasound-guided arthrocentesis, which demonstrated a Cronbach's alpha of 0.89, indicating an excellent degree of internal consistency. Although we were able to demonstrate content validity for this tool, further validity evidence should be acquired after the tool is used and studied in clinical and simulated contexts. © 2017 by the American Institute of Ultrasound in Medicine.

  11. Pathological fracture of the patella due to an atypical located aneurysmal bone cyst: verification by means of ultrasound-guided biopsy.

    PubMed

    Plaikner, Michaela; Gruber, Hannes; Henninger, Benjamin; Gruber, Leonhard; Kosiol, Juana; Loizides, Alexander

    2016-03-01

    We report on a rare case of an atypical located aneurysmal bone cyst (ABC) in the patella presenting with pathological fracture after trauma. Using all available diagnostic modalities and by means of ultrasound-guided core-needle biopsy an unclear and suspected pathological fractured cystic bone lesion in the patella of a young man could be further clarified. The acquired images suggested the diagnosis of a pathological fractured aneurysmal bone cyst after mild trauma. However, due to the extraordinary location and clinical presentation the diagnosis was secured by means of ultrasound-guided biopsy through a small cortical gap. As shown in this rare case of an atypical aneurysmal bone cyst of the patella, the quite seldom but sometimes possible ultrasound-guided biopsy of intraosseous lesions can help to achieve the diagnostic clarification and should also be taken into account as a non-standard procedure.

  12. Minimally Invasive Ultrasound-Guided Carpal Tunnel Release: Preliminary Clinical Results.

    PubMed

    Henning, P Troy; Yang, Lynda; Awan, Tariq; Lueders, Daniel; Pourcho, Adam M

    2018-04-02

    Ultrasound-guided carpal tunnel release was performed on 14 patients (18 wrists) using dynamic expansion of the transverse safe zone. Our patient population included able-bodied patients and those with impairments. The first 8 cases (12 wrists) underwent the procedure in an operating room, the remainder in an outpatient setting. No complications occurred, and all patients were able to immediately resume use of their hands without therapy. Improvements in the Quick Form of the Disabilities of the Arm, Shoulder, and Hand Index and Boston Carpal Tunnel Questionnaire at 3 months were comparable to results reported with mini-open and endoscopic release. Our results show that ultrasound-guided carpal tunnel release can be safely and effectively performed in an outpatient setting. © 2018 by the American Institute of Ultrasound in Medicine.

  13. Hemodialysis catheter implantation in the axillary vein by ultrasound guidance versus palpation or anatomical reference

    PubMed Central

    Valencia, Cesar A Restrepo; Villa, Carlos A Buitrago; Cardona, Jose A Chacon

    2013-01-01

    Background We compared the results of four different methods of hemodialysis catheter insertion in the medial segment of the axillary vein: ultrasound guidance, palpation, anatomical reference, and prior transient catheter. Methods All patients that required acute or chronic hemodialysis and for whom it was determined impossible or not recommended either to place a catheter in the internal jugular vein (for instance, those patients with a tracheostomy), or to practice arteriovenous fistula or graft; it was then essential to obtain an alternative vascular access. When the procedure of axillary vein catheter insertion was performed in the Renal Care Facility (RCF), ultrasound guidance was used, but in the intensive care unit (ICU), this resource was unavailable, so the palpation or anatomical reference technique was used. Results Two nephrologists with experience in the technique performed 83 procedures during a period lasting 15 years and 8 months (from January 1997–August 2012): 41 by ultrasound guidance; 19 by anatomical references; 15 by palpation of the contiguous axillary artery; and 8 through a temporary axillary catheter previously placed. The ultrasound-guided patients had fewer punctures than other groups, but the value was not statistically significant. Arterial punctures were infrequent in all techniques. Analyzing all the procedure-related complications, such as hematoma, pneumothorax, brachial-plexus injury, as well as the reasons for catheter removal, no differences were observed among the groups. The functioning time was longer in the ultrasound-guided and previous catheter groups. In 15 years and 8 months of surveillance, no clinical or image evidence for axillary vein stenosis was found. Conclusion The ultrasound guide makes the procedure of inserting catheters in the axillary veins easier, but knowledge of the anatomy of the midaxillary region and the ability to feel the axillary artery pulse (for the palpation method) also allow relatively easy successful implant of catheters in the axillary veins. PMID:24143120

  14. Mondor's disease of the breast as a complication of ultrasound-guided core needle biopsy: management and review of the literature.

    PubMed

    Salemis, Nikolaos S; Vasilara, Georgia; Lagoudianakis, Emmanuel

    2015-01-01

    Mondor's disease is a rare benign and self-limiting condition characterized by thrombophlebitis of the superficial veins of the anterolateral thoracoabdominal wall. We describe a case of Mondor's disease of the breast as a complication of an ultrasound-guided core needle biospy. The patient presented with a palpable cord-like structure in her left breast, associated with severe pain and tenderness. She was treated concervatively and complete resolution was observed after four weeks. We conclude that emergency clinicians and interventional breast radiologists should be aware of Mondor's disease as a potential complication of ultrasound-guided core needle biopsy of the breast.

  15. Ultrasound-guided thrombin injection of genicular artery pseudoaneurysm.

    PubMed

    Rachakonda, Aditya; Qato, Khalil; Khaddash, Tamim; Carroccio, Alfio; Pamoukian, Vicken; Giangola, Gary

    2015-07-01

    Pseudoaneurysm is a rare complication after arthroscopic procedures involving the knee. A 38-year-old man presented 1 month after right-knee arthroscopy with a 2-cm pulsating mass on the medial side of the right knee. Duplex ultrasound evaluation revealed 2.5 × 2.1-cm pseudoaneurysm just distal to the patella with arterialized flow communicating with the inferior medial genicular artery. Ultrasound-guided thrombin injection was performed in an office setting, and the resolution of active flow within the pseudoaneurysm was confirmed with duplex ultrasonography. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Safety of Ultrasound-Guided Botulinum Toxin Injections for Sialorrhea as Performed by Pediatric Otolaryngologists.

    PubMed

    Shariat-Madar, Bahbak; Chun, Robert H; Sulman, Cecille G; Conley, Stephen F

    2016-05-01

    To evaluate incidence of complications and hospital readmission as a result of ultrasound-guided botulinum toxin injections to manage sialorrhea. Case series with chart review. Children's Hospital of Wisconsin. A case series with chart review was performed of all cases of ultrasound-guided injection of botulinum toxin by pediatric otolaryngologists from March 5, 2010, to September 26, 2014,. Primary outcomes included complications such as dysphagia, aspiration pneumonia, and motor paralysis. Secondary outcomes included hospitalization, intubation, and nasogastric tube placement. There were 48 patients, 111 interventions, and 306 intraglandular injections identified. Botulinum toxin type A and type B were utilized in 4 and 107 operative interventions, respectively. Type A was injected into 4 parotid and 4 submandibular glands, utilizing doses of 20 U per parotid and 30 U per submandibular gland. Type B was injected into 98 parotid and 200 submandibular glands, with average dosing of 923 U per parotid and 1170 U per submandibular gland, respectively. There were 2 instances of subjectively worsening of baseline dysphagia that self-resolved. No cases were complicated by aspiration pneumonia or motor paralysis. No patients required hospital readmission, intubation, or nasogastric tube placement. Prior published data indicated 16% complication incidence with ultrasound-guided injection of botulinum toxin. Our study found a low complication rate (0.6%) with ultrasound-guided injections of botulinum toxin to manage sialorrhea, without cases of aspiration pneumonia or motor paralysis. Of 306 intraglandular injections, there were 2 cases of worsening baseline subjective dysphagia that self-resolved. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2016.

  17. Establishing intensivist-driven ultrasound at the PICU bedside--it's about time*.

    PubMed

    Su, Erik; Pustavoitau, Aliaksei; Hirshberg, Elliotte L; Nishisaki, Akira; Conlon, Thomas; Kantor, David B; Weber, Mark D; Godshall, Aaron J; Burzynski, Jeffrey H; Thompson, Ann E

    2014-09-01

    To discuss pediatric intensivist-driven ultrasound and the exigent need for research and practice definitions pertaining to its implementation within pediatric critical care, specifically addressing issues in ultrasound-guided vascular access and intensivist-driven echocardiography. Intensivist-driven ultrasound improves procedure safety and reduces time to diagnosis in clinical ultrasound applications, as demonstrated primarily in adult patients. Translating these applications to the PICU requires thoughtful integration of the technology into practice and would best be informed by dedicated ultrasound research in critically ill children.

  18. Cost-effectiveness of focused ultrasound, radiosurgery, and DBS for essential tremor.

    PubMed

    Ravikumar, Vinod K; Parker, Jonathon J; Hornbeck, Traci S; Santini, Veronica E; Pauly, Kim Butts; Wintermark, Max; Ghanouni, Pejman; Stein, Sherman C; Halpern, Casey H

    2017-08-01

    Essential tremor remains a very common yet medically refractory condition. A recent phase 3 study demonstrated that magnetic resonance-guided focused ultrasound thalamotomy significantly improved upper limb tremor. The objectives of this study were to assess this novel therapy's cost-effectiveness compared with existing procedural options. Literature searches of magnetic resonance-guided focused ultrasound thalamotomy, DBS, and stereotactic radiosurgery for essential tremor were performed. Pre- and postoperative tremor-related disability scores were collected from 32 studies involving 83 magnetic resonance-guided focused ultrasound thalamotomies, 615 DBSs, and 260 stereotactic radiosurgery cases. Utility, defined as quality of life and derived from percent change in functional disability, was calculated; Medicare reimbursement was employed as a proxy for societal cost. Medicare reimbursement rates are not established for magnetic resonance-guided focused ultrasound thalamotomy for essential tremor; therefore, reimbursements were estimated to be approximately equivalent to stereotactic radiosurgery to assess a cost threshold. A decision analysis model was constructed to examine the most cost-effective option for essential tremor, implementing meta-analytic techniques. Magnetic resonance-guided focused ultrasound thalamotomy resulted in significantly higher utility scores compared with DBS (P < 0.001) or stereotactic radiosurgery (P < 0.001). Projected costs of magnetic resonance-guided focused ultrasound thalamotomy were significantly less than DBS (P < 0.001), but not significantly different from radiosurgery. Magnetic resonance-guided focused ultrasound thalamotomy is cost-effective for tremor compared with DBS and stereotactic radiosurgery and more effective than both. Even if longer follow-up finds changes in effectiveness or costs, focused ultrasound thalamotomy will likely remain competitive with both alternatives. © 2017 International Parkinson and Movement Disorder Society. © 2017 International Parkinson and Movement Disorder Society.

  19. Lung cancer diagnosis and staging with endobronchial ultrasound-guided transbronchial needle aspiration compared with conventional approaches: an open-label, pragmatic, randomised controlled trial

    PubMed Central

    Navani, Neal; Nankivell, Matthew; Lawrence, David R; Lock, Sara; Makker, Himender; Baldwin, David R; Stephens, Richard J; Parmar, Mahesh K; Spiro, Stephen G; Morris, Stephen; Janes, Sam M

    2015-01-01

    Summary Background The diagnosis and staging of lung cancer is an important process that identifies treatment options and guides disease prognosis. We aimed to assess endobronchial ultrasound-guided transbronchial needle aspiration as an initial investigation technique for patients with suspected lung cancer. Methods In this open-label, multicentre, pragmatic, randomised controlled trial, we recruited patients who had undergone a CT scan and had suspected stage I to IIIA lung cancer, from six UK centres and randomly assigned them to either endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) or conventional diagnosis and staging (CDS), for further investigation and staging. If a target node could not be accessed by EBUS-TBNA, then endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) was allowed as an alternative procedure. Randomisation was stratified according to the presence of mediastinal lymph nodes measuring 1 cm or more in the short axis and by recruiting centre. We used a telephone randomisation method with permuted blocks of four generated by a computer. Because of the nature of the intervention, masking of participants and consenting investigators was not possible. The primary endpoint was the time-to-treatment decision after completion of the diagnostic and staging investigations and analysis was by intention-to-diagnose. This trial is registered with ClinicalTrials.gov, number NCT00652769. Findings Between June 10, 2008, and July 4, 2011, we randomly allocated 133 patients to treatment: 66 to EBUS-TBNA and 67 to CDS (one later withdrew consent). Two patients from the EBUS-TBNA group underwent EUS-FNA. The median time to treatment decision was shorter with EBUS-TBNA (14 days; 95% CI 14–15) than with CDS (29 days; 23–35) resulting in a hazard ratio of 1·98, (1·39–2·82, p<0·0001). One patient in each group had a pneumothorax from a CT-guided biopsy sample; the patient from the CDS group needed intercostal drainage and was admitted to hospital. Interpretation Transbronchial needle aspiration guided by endobronchial ultrasound should be considered as the initial investigation for patients with suspected lung cancer, because it reduces the time to treatment decision compared with conventional diagnosis and staging techniques. Funding UK Medical Research Council. PMID:25660225

  20. Newly-developed, forward-viewing echoendoscope: a comparative pilot study to the standard echoendoscope in the imaging of abdominal organs and feasibility of endoscopic ultrasound-guided interventions.

    PubMed

    Iwashita, Takuji; Nakai, Yousuke; Lee, John G; Park, Do Hyun; Muthusamy, V Raman; Chang, Kenneth J

    2012-02-01

    Multiple diagnostic and therapeutic endoscopic ultrasound (EUS) procedures have been widely performed using a standard oblique-viewing (OV) curvilinear array (CLA) echoendoscope. Recently, a new, forward-viewing (FV) CLA was developed, with the advantages of improved endoscopic viewing and manipulation of devices. However, the FV-CLA echoendoscope has a narrower ultrasound scanning field, and lacks an elevator, which might represent obstacles for clinical use. The aim of this study was to compare the FV-CLA echoendoscope to the OV-CLA echoendoscope for EUS imaging of abdominal organs, and to assess the feasibility of EUS-guided interventions using the FV-CLA echoendoscope. EUS examinations were first performed and recorded using the OV-CLA echoendoscope, followed immediately by the FV-CLA echoendoscope. Video recordings were then assessed by two independent endosonographers in a blinded fashion. The EUS visualization and image quality of specific abdominal organs/structures were scored. Any indicated fine-needle aspiration (FNA) or intervention was performed using the FV-CLA echoendoscope, with the OV-CLA echoendoscope as salvage upon failure. A total of 21 patients were examined in the study. Both echoendoscopes had similar visualization and image quality for all organs/structures, except the common hepatic duct (CHD), which was seen significantly better with the FV-CLA echoendoscope. EUS interventions were conducted in eight patients, including FNA of pancreatic mass (3), pancreatic cyst (3), and cystgastrostomy (2). The FV-CLA echoendoscope was successful in seven patients. One failed FNA of the pancreatic head cyst was salvaged using the OV-CLA echoendoscope. There were no differences between the FV-CLA echoendoscope and the OV-CLA echoendoscope in visualization or image quality on upper EUS, except for the superior image quality of CHD using the FV-CLA echoendoscope. Therefore, the disadvantages of the FV-CLA echoendoscope appear minimal in light of the potential advantages. © 2011 Journal of Gastroenterology and Hepatology Foundation and Blackwell Publishing Asia Pty Ltd.

  1. Ultrasound-Guided Percutaneous Nephrostomy Performed on Neonates and Infants Using a "14-4" (Trocar and Cannula) Technique.

    PubMed

    Bas, Ahmet; Gülşen, Fatih; Emre, Senol; Samanci, Cesur; Uzunlu, Osman; Cantasdemir, Murat; Emir, Haluk; Numan, Furuzan

    2015-12-01

    Percutaneous nephrostomy (PCN) catheters are placed under combined ultrasound and fluoroscopic guidance in the interventional radiology suite and present unique challenges in neonates and infants. The purpose of this study was to demonstrate feasibility of PCN using a "14-4" (trocar and cannula) technique on neonates and infants. Between September 2009 and June 2014, data for 27 kidneys from consecutive 22 neonates or infants who underwent PCN catheter placement using the "14-4" technique were retrospectively analyzed. The median age at the time of placement of the PCN catheters was 11 days (range 5-300 days). There were 18 males and 4 females. All procedures were performed in the interventional radiology suite but without using fluoroscopy. Unilateral PCN was performed on 17 out of 22 patients, while bilateral drainage was performed on five patients. The technical success rate was 100%. The median duration of PCN catheter was 75 days (range 10-138 days). Minor macroscopic hematuria not requiring blood transfusion was present in two of the patients in which the hematuria lasted in 2 days. Placement of PCN catheters using a "14-4" technique with ultrasound as the sole imaging modality is a technically feasible and desirable option for neonates or infants. The technique obviates the need for ionizing radiation and potentially could be performed in the ultrasound room or even at the bedside.

  2. Development of a 3D ultrasound-guided prostate biopsy system

    NASA Astrophysics Data System (ADS)

    Cool, Derek; Sherebrin, Shi; Izawa, Jonathan; Fenster, Aaron

    2007-03-01

    Biopsy of the prostate using ultrasound guidance is the clinical gold standard for diagnosis of prostate adenocarinoma. However, because early stage tumors are rarely visible under US, the procedure carries high false-negative rates and often patients require multiple biopsies before cancer is detected. To improve cancer detection, it is imperative that throughout the biopsy procedure, physicians know where they are within the prostate and where they have sampled during prior biopsies. The current biopsy procedure is limited to using only 2D ultrasound images to find and record target biopsy core sample sites. This information leaves ambiguity as the physician tries to interpret the 2D information and apply it to their 3D workspace. We have developed a 3D ultrasound-guided prostate biopsy system that provides 3D intra-biopsy information to physicians for needle guidance and biopsy location recording. The system is designed to conform to the workflow of the current prostate biopsy procedure, making it easier for clinical integration. In this paper, we describe the system design and validate its accuracy by performing an in vitro biopsy procedure on US/CT multi-modal patient-specific prostate phantoms. A clinical sextant biopsy was performed by a urologist on the phantoms and the 3D models of the prostates were generated with volume errors less than 4% and mean boundary errors of less than 1 mm. Using the 3D biopsy system, needles were guided to within 1.36 +/- 0.83 mm of 3D targets and the position of the biopsy sites were accurately localized to 1.06 +/- 0.89 mm for the two prostates.

  3. The role of endoscopic intervention in the management of inflammatory pancreatic fluid collections.

    PubMed

    Parihar, Vikrant; Ridgway, Paul F; Conlon, Kevin C; Huggett, Matthew; Ryan, Barbara M

    2017-04-01

    Pancreatic fluid collections (PFCs) are a frequent complication of pancreatitis, or less commonly, pancreatic trauma or surgery. The revised Atlanta Classification categorizes PFCs as acute or chronic, with further subclassification of acute collections into acute peripancreatic collections and acute necrotic collections and of chronic fluid collections into pseudocysts and walled-off pancreatic necrosis. Acute PFCs are generally only subjected to an intervention when they are infected and not responding to antibiotics and are not managed endoscopically. Chronic PFCs, both pseudocysts and walled-off pancreatic necrosis, require intervention only when symptomatic or enlarging over time. Endoscopic ultrasound-guided drainage has become the mainstay of management for chronic PFCs that require intervention. Developments in medical devices over the past few years have significantly simplified and shortened the duration of the procedure itself, but the optimum choice of stent in different clinical scenarios remains to be defined, as does the place of endoscopic necrosectomy. To optimize outcomes, these patients should undergo a careful preprocedure workup and discussion in a multidisciplinary environment and procedures should be carried out in high-volume pancreatic units.

  4. [Assessment of amylase and lipase levels following puncture biopsy and fine needle aspiration guided by endoscopic ultrasound in pancreatic lesions].

    PubMed

    Membrillo-Romero, Alejandro; Gonzalez-Lanzagorta, Rubén; Rascón-Martínez, Dulce María

    Puncture biopsy and fine needle aspiration guided by endoscopic ultrasound has been used as an effective technique and is quickly becoming the procedure of choice for diagnosis and staging in patients suspected of having pancreatic cancer. This procedure has replaced retrograde cholangiopancreatography and brush cytology due to its higher sensitivity for diagnosis, and lower risk of complications. To assess the levels of pancreatic enzymes amylase and lipase, after the puncture biopsy and fine needle aspiration guided by endoscopic ultrasound in pancreatic lesions and the frequency of post-puncture acute pancreatitis. A longitudinal and descriptive study of consecutive cases was performed on outpatients submitted to puncture biopsy and fine needle aspiration guided by endoscopic ultrasound in pancreatic lesions. Levels of pancreatic enzymes such as amylase and lipase were measured before and after the pancreatic puncture. Finally we documented post-puncture pancreatitis cases. A total of 100 patients who had been diagnosed with solid and cystic lesions were included in the study. Significant elevation was found at twice the reference value for lipase in 5 cases (5%) and for amylase in 2 cases (2%), none had clinical symptoms of acute pancreatitis. Eight (8%) of patients presented with mild nonspecific pain with no enzyme elevation compatible with pancreatitis. Pancreatic biopsy needle aspiration guided by endoscopic ultrasound was associated with a low rate of elevated pancreatic enzymes and there were no cases of post-puncture pancreatitis. Copyright © 2016 Academia Mexicana de Cirugía A.C. Publicado por Masson Doyma México S.A. All rights reserved.

  5. High-frequency ultrasound imaging for breast cancer biopsy guidance

    PubMed Central

    Cummins, Thomas; Yoon, Changhan; Choi, Hojong; Eliahoo, Payam; Kim, Hyung Ham; Yamashita, Mary W.; Hovanessian-Larsen, Linda J.; Lang, Julie E.; Sener, Stephen F.; Vallone, John; Martin, Sue E.; Kirk Shung, K.

    2015-01-01

    Abstract. Image-guided core needle biopsy is the current gold standard for breast cancer diagnosis. Microcalcifications, an important radiographic finding on mammography suggestive of early breast cancer such as ductal carcinoma in situ, are usually biopsied under stereotactic guidance. This procedure, however, is uncomfortable for patients and requires the use of ionizing radiation. It would be preferable to biopsy microcalcifications under ultrasound guidance since it is a faster procedure, more comfortable for the patient, and requires no radiation. However, microcalcifications cannot reliably be detected with the current standard ultrasound imaging systems. This study is motivated by the clinical need for real-time high-resolution ultrasound imaging of microcalcifications, so that biopsies can be accurately performed under ultrasound guidance. We have investigated how high-frequency ultrasound imaging can enable visualization of microstructures in ex vivo breast tissue biopsy samples. We generated B-mode images of breast tissue and applied the Nakagami filtering technique to help refine image output so that microcalcifications could be better assessed during ultrasound-guided core biopsies. We describe the preliminary clinical results of high-frequency ultrasound imaging of ex vivo breast biopsy tissue with microcalcifications and without Nakagami filtering and the correlation of these images with the pathology examination by hematoxylin and eosin stain and whole slide digital scanning. PMID:26693167

  6. Ultrasound guided placement of the distal catheter in paediatric ventriculoatrial shunts-an appraisal of efficacy and complications.

    PubMed

    Clark, David J; Chakraborty, Aabir; Roebuck, Derek J; Thompson, Dominic N P

    2016-07-01

    Ventriculoatrial (VA) shunts are commonly used as a second-line treatment of hydrocephalus when the peritoneum is an unsuitable site for the distal catheter. Many centres now utilise ultrasound and interventional radiology techniques to aid placement of the distal catheter. The purpose of this study was to conduct a contemporary audit of VA shunting in children using interventional radiology techniques for placement of the distal catheter. A retrospective analysis of all patients who had VA shunts inserted between June 2000 and June 2010 was conducted using a prospectively updated surgical database and case notes review. Ninety-four VA shunts were inserted in 38 patients. Thirty-seven patients had been treated initially with ventriculoperitoneal (VP) shunts. Twenty-two patients required at least 1 shunt revision (58 %). The 6-month, 1- and 2-year shunt survival rates were 53, 43 and 27 %, respectively. Blockage was the commonest reason for shunt failure (68 %). The site of failure was proximal (ventricular catheter +/- valve) in 32 % and distal (atrial catheter) in 21 % of cases. The overall infection rate was 6 % per procedure and 11 % per patient. There were 7 deaths, of which 3 were shunt related. VA shunting provides a viable second-line option for shunt placement in complex hydrocephalus. The causes of shunt failure (blockage, infection and equipment failure) are similar to VP shunting though shunt survival rates are inferior to VP shunts. Ultrasound guided VA shunt placement provides a relatively safe, second-line alternative to the placement of a ventriculoperitoneal shunt when this route is unsuitable.

  7. Introducing a Fresh Cadaver Model for Ultrasound-guided Central Venous Access Training in Undergraduate Medical Education

    PubMed Central

    Miller, Ryan; Ho, Hang; Ng, Vivienne; Tran, Melissa; Rappaport, Douglas; Rappaport, William J.A.; Dandorf, Stewart J.; Dunleavy, James; Viscusi, Rebecca; Amini, Richard

    2016-01-01

    Introduction Over the past decade, medical students have witnessed a decline in the opportunities to perform technical skills during their clinical years. Ultrasound-guided central venous access (USG-CVA) is a critical procedure commonly performed by emergency medicine, anesthesia, and general surgery residents, often during their first month of residency. However, the acquisition of skills required to safely perform this procedure is often deficient upon graduation from medical school. To ameliorate this lack of technical proficiency, ultrasound simulation models have been introduced into undergraduate medical education to train venous access skills. Criticisms of simulation models are the innate lack of realistic tactile qualities, as well as the lack of anatomical variances when compared to living patients. The purpose of our investigation was to design and evaluate a life-like and reproducible training model for USG-CVA using a fresh cadaver. Methods This was a cross-sectional study at an urban academic medical center. An 18-point procedural knowledge tool and an 18-point procedural skill evaluation tool were administered during a cadaver lab at the beginning and end of the surgical clerkship. During the fresh cadaver lab, procedure naïve third-year medical students were trained on how to perform ultrasound-guided central venous access of the femoral and internal jugular vessels. Preparation of the fresh cadaver model involved placement of a thin-walled latex tubing in the anatomic location of the femoral and internal jugular vein respectively. Results Fifty-six third-year medical students participated in this study during their surgical clerkship. The fresh cadaver model provided high quality and lifelike ultrasound images despite numerous cannulation attempts. Technical skill scores improved from an average score of 3 to 12 (p<0.001) and procedural knowledge scores improved from an average score of 4 to 8 (p<0.001). Conclusion The use of this novel cadaver model prevented extravasation of fluid, maintained ultrasound-imaging quality, and proved to be an effective educational model allowing third-year medical students to improve and maintain their technical skills. PMID:27330672

  8. Introducing a Fresh Cadaver Model for Ultrasound-guided Central Venous Access Training in Undergraduate Medical Education.

    PubMed

    Miller, Ryan; Ho, Hang; Ng, Vivienne; Tran, Melissa; Rappaport, Douglas; Rappaport, William J A; Dandorf, Stewart J; Dunleavy, James; Viscusi, Rebecca; Amini, Richard

    2016-05-01

    Over the past decade, medical students have witnessed a decline in the opportunities to perform technical skills during their clinical years. Ultrasound-guided central venous access (USG-CVA) is a critical procedure commonly performed by emergency medicine, anesthesia, and general surgery residents, often during their first month of residency. However, the acquisition of skills required to safely perform this procedure is often deficient upon graduation from medical school. To ameliorate this lack of technical proficiency, ultrasound simulation models have been introduced into undergraduate medical education to train venous access skills. Criticisms of simulation models are the innate lack of realistic tactile qualities, as well as the lack of anatomical variances when compared to living patients. The purpose of our investigation was to design and evaluate a life-like and reproducible training model for USG-CVA using a fresh cadaver. This was a cross-sectional study at an urban academic medical center. An 18-point procedural knowledge tool and an 18-point procedural skill evaluation tool were administered during a cadaver lab at the beginning and end of the surgical clerkship. During the fresh cadaver lab, procedure naïve third-year medical students were trained on how to perform ultrasound-guided central venous access of the femoral and internal jugular vessels. Preparation of the fresh cadaver model involved placement of a thin-walled latex tubing in the anatomic location of the femoral and internal jugular vein respectively. Fifty-six third-year medical students participated in this study during their surgical clerkship. The fresh cadaver model provided high quality and lifelike ultrasound images despite numerous cannulation attempts. Technical skill scores improved from an average score of 3 to 12 (p<0.001) and procedural knowledge scores improved from an average score of 4 to 8 (p<0.001). The use of this novel cadaver model prevented extravasation of fluid, maintained ultrasound-imaging quality, and proved to be an effective educational model allowing third-year medical students to improve and maintain their technical skills.

  9. Physics and instrumentation of ultrasound.

    PubMed

    Lawrence, John P

    2007-08-01

    A thorough understanding of the physics of ultrasound waves and the instrumentation will provide the user with a better understanding of the capabilities and limitations of ultrasound equipment. The ultrasound machine combines two technologies: image production (M-mode and 2-dimensional imaging) with Doppler assessment (continuous and pulse wave as well as color-flow mapping). These distinct technologies have been combined to provide the examiner with the ability to make accurate and comprehensive diagnoses and guide therapeutic intervention.

  10. Training and certification in endobronchial ultrasound-guided transbronchial needle aspiration

    PubMed Central

    Konge, Lars; Nayahangan, Leizl Joy; Clementsen, Paul Frost

    2017-01-01

    Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) plays a key role in the staging of lung cancer, which is crucial for allocation to surgical treatment. EBUS-TBNA is a complicated procedure and simulation-based training is helpful in the first part of the long learning curve prior to performing the procedure on actual patients. New trainees should follow a structured training programme consisting of training on simulators to proficiency as assessed with a validated test followed by supervised practice on patients. The simulation-based training is superior to the traditional apprenticeship model and is recommended in the newest guidelines. EBUS-TBNA and oesophageal ultrasound-guided fine needle aspiration (EUS-FNA or EUS-B-FNA) are complementary to each other and the combined techniques are superior to either technique alone. It is logical to learn and to perform the two techniques in combination, however, for lung cancer staging solely EBUS-TBNA simulators exist, but hopefully in the future simulation-based training in EUS will be possible. PMID:28840013

  11. Image registration: enabling technology for image guided surgery and therapy.

    PubMed

    Sauer, Frank

    2005-01-01

    Imaging looks inside the patient's body, exposing the patient's anatomy beyond what is visible on the surface. Medical imaging has a very successful history for medical diagnosis. It also plays an increasingly important role as enabling technology for minimally invasive procedures. Interventional procedures (e.g. catheter based cardiac interventions) are traditionally supported by intra-procedure imaging (X-ray fluoro, ultrasound). There is realtime feedback, but the images provide limited information. Surgical procedures are traditionally supported with pre-operative images (CT, MR). The image quality can be very good; however, the link between images and patient has been lost. For both cases, image registration can play an essential role -augmenting intra-op images with pre-op images, and mapping pre-op images to the patient's body. We will present examples of both approaches from an application oriented perspective, covering electrophysiology, radiation therapy, and neuro-surgery. Ultimately, as the boundaries between interventional radiology and surgery are becoming blurry, also the different methods for image guidance will merge. Image guidance will draw upon a combination of pre-op and intra-op imaging together with magnetic or optical tracking systems, and enable precise minimally invasive procedures. The information is registered into a common coordinate system, and allows advanced methods for visualization such as augmented reality or advanced methods for therapy delivery such as robotics.

  12. Long-term outcome of ultrasound-guided percutaneous ethanol ablation of selected "recurrent" neck nodal metastases in 25 patients with TNM stages III or IVA papillary thyroid carcinoma previously treated by surgery and 131I therapy.

    PubMed

    Hay, Ian D; Lee, Robert A; Davidge-Pitts, Caroline; Reading, Carl C; Charboneau, J William

    2013-12-01

    Ultrasound-guided percutaneous ethanol ablation (UPEA) of neck nodal metastases (NNM) has rarely been reported in papillary thyroid carcinoma (PTC) patients with advanced localized disease. We ablated 25 PTC patients with stage III or IVA disease (mean age 58 years) who had "recurrent" NNM after surgery and 131I therapy. Diagnosis of 37 selected NNM was proven by ultrasound-guided biopsy. UPEA was usually performed in 2 outpatient sessions. After UPEA, 35 of 37 NNM (95%) decreased in size. None had significant Doppler flow. Seventeen (46%) disappeared on rescanning. Serum thyroglobulin fell in 19 of 22 (86%) without thyroglobulin autoantibodies. None of the UPEA-treated NNM, followed on average for 5.4 years, required further intervention. Six patients (24%) subsequently developed 18 "new" recurrences. Of the 18, 15 (83%) were managed successfully by UPEA rather than operation. None of the 25 patients developed permanent hoarseness or have died from PTC. At our institution, where patients undergoing nodal dissections are charged $35-45,000, each outpatient UPEA procedure saves health providers approximately $38,400. Our 25 ablated patients, by avoiding 40 further neck reexplorations, on average, saved $61,440 in charges. UPEA for NNM in advanced localized PTC has proved safe and effective. It is also considerably less expensive than the conventional operative alternative of nodal dissection. Copyright © 2013 Mosby, Inc. All rights reserved.

  13. Image-guided endobronchial ultrasound

    NASA Astrophysics Data System (ADS)

    Higgins, William E.; Zang, Xiaonan; Cheirsilp, Ronnarit; Byrnes, Patrick; Kuhlengel, Trevor; Bascom, Rebecca; Toth, Jennifer

    2016-03-01

    Endobronchial ultrasound (EBUS) is now recommended as a standard procedure for in vivo verification of extraluminal diagnostic sites during cancer-staging bronchoscopy. Yet, physicians vary considerably in their skills at using EBUS effectively. Regarding existing bronchoscopy guidance systems, studies have shown their effectiveness in the lung-cancer management process. With such a system, a patient's X-ray computed tomography (CT) scan is used to plan a procedure to regions of interest (ROIs). This plan is then used during follow-on guided bronchoscopy. Recent clinical guidelines for lung cancer, however, also dictate using positron emission tomography (PET) imaging for identifying suspicious ROIs and aiding in the cancer-staging process. While researchers have attempted to use guided bronchoscopy systems in tandem with PET imaging and EBUS, no true EBUS-centric guidance system exists. We now propose a full multimodal image-based methodology for guiding EBUS. The complete methodology involves two components: 1) a procedure planning protocol that gives bronchoscope movements appropriate for live EBUS positioning; and 2) a guidance strategy and associated system graphical user interface (GUI) designed for image-guided EBUS. We present results demonstrating the operation of the system.

  14. Real-time integrated photoacoustic and ultrasound (PAUS) imaging system to guide interventional procedures: ex vivo study.

    PubMed

    Wei, Chen-Wei; Nguyen, Thu-Mai; Xia, Jinjun; Arnal, Bastien; Wong, Emily Y; Pelivanov, Ivan M; O'Donnell, Matthew

    2015-02-01

    Because of depth-dependent light attenuation, bulky, low-repetition-rate lasers are usually used in most photoacoustic (PA) systems to provide sufficient pulse energies to image at depth within the body. However, integrating these lasers with real-time clinical ultrasound (US) scanners has been problematic because of their size and cost. In this paper, an integrated PA/US (PAUS) imaging system is presented operating at frame rates >30 Hz. By employing a portable, low-cost, low-pulse-energy (~2 mJ/pulse), high-repetition-rate (~1 kHz), 1053-nm laser, and a rotating galvo-mirror system enabling rapid laser beam scanning over the imaging area, the approach is demonstrated for potential applications requiring a few centimeters of penetration. In particular, we demonstrate here real-time (30 Hz frame rate) imaging (by combining multiple single-shot sub-images covering the scan region) of an 18-gauge needle inserted into a piece of chicken breast with subsequent delivery of an absorptive agent at more than 1-cm depth to mimic PAUS guidance of an interventional procedure. A signal-to-noise ratio of more than 35 dB is obtained for the needle in an imaging area 2.8 × 2.8 cm (depth × lateral). Higher frame rate operation is envisioned with an optimized scanning scheme.

  15. Utility of rapid on-site cytologic evaluation during endobronchial ultrasound with a guide sheath for peripheral pulmonary lesions.

    PubMed

    Izumo, Takehiro; Matsumoto, Yuji; Sasada, Shinji; Chavez, Christine; Nakai, Toshiyuki; Tsuchida, Takaaki

    2017-03-01

    The utility of rapid on-site evaluation during endobronchial ultrasound with a guide sheath for peripheral pulmonary lesions is unclear. The aim of this study was to evaluate the role of rapid on-site evaluation during endobronchial ultrasound with a guide sheath for peripheral pulmonary lesions. Consecutive patients who underwent endobronchial ultrasound with a guide sheath for the diagnosis of peripheral pulmonary lesions at our hospital between September 2012 and July 2014 were included in this retrospective study. Cytology slides were air-dried, and modified Giemsa (Diff-Quik) staining was used for rapid on-site evaluation. Additional smears were prepared for Papanicolaou staining and tissue samples were placed in formalin for histologic evaluation. The results of rapid on-site evaluation were compared with the final diagnoses of endobronchial ultrasound with a guide sheath. A total of 718 cases were included in the study population. The sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy of rapid on-site evaluation during endobronchial ultrasound with a guide sheath for peripheral pulmonary lesions was 88.6%, 65.9%, 81.2%, 77.7% and 80.1%, respectively. There were no procedure-related deaths. Rapid on-site evaluation during endobronchial ultrasound with a guide sheath had high sensitivity for peripheral pulmonary lesions. When carrying out rapid on-site evaluation of transbronchial biopsy samples from peripheral pulmonary lesions, careful interpretation and clinical correlation are necessary. © The Author 2016. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  16. Ultrasound-Guided Liver Biopsy With Gelatin Sponge Pledget Tract Embolization in Infants Weighing Less Than 10 kg.

    PubMed

    Lungren, Matthew P; Lindquester, Will S; Seidel, Frank Glen; Kothary, Nishita; Monroe, Eric J; Shivaram, Giri; Gill, Anne E; Hawkins, Matthew C

    2016-12-01

    The aim of the study was to describe and assess the technical success and safety of ultrasound-guided liver biopsy with gelatin sponge pledget tract embolization technique in infants <10 kg across 3 tertiary pediatric hospitals. There were 67 pediatric patients weighing <10 kg (36 boys; 31 girls; average age 202 days; average weight 6 kg, range 1.5-9.9 kg) referred for liver biopsy performed with ultrasound guidance and gelatin sponge pledget tract embolization during a 2-year period. Patient history, procedural records, and clinical follow-up documents were retrospectively reviewed. A total of 67 procedures were included. There was 100% technical success rate and all samples obtained provided adequate tissue for histological assessment. Average number of 18 G biopsy passes was 3 (range 1-6). There were no procedure-related deaths. There was 1 complication (1%) in a 5-kg infant who was readmitted 36 hours after biopsy with a fever and fully recovered after antibiotics were administered. Biliary atresia was the most common underlying diagnosis (20%), whereas others included acute rejection (16%) and biliary obstruction (7%). Ultrasound-guided percutaneous liver biopsy with gelatin sponge pledget tract embolization technique in children weighing <10 kg is safe, effective, and use of this technique may lead to a reduction in rates of adverse events reported in other pediatric series.

  17. Simulators for training in ultrasound guided procedures.

    PubMed

    Farjad Sultan, Syed; Shorten, George; Iohom, Gabrielle

    2013-06-01

    The four major categories of skill sets associated with proficiency in ultrasound guided regional anaesthesia are 1) understanding device operations, 2) image optimization, 3) image interpretation and 4) visualization of needle insertion and injection of the local anesthetic solution. Of these, visualization of needle insertion and injection of local anaesthetic solution can be practiced using simulators and phantoms. This survey of existing simulators summarizes advantages and disadvantages of each. Current deficits pertain to the validation process.

  18. Ultrasound and Fluoroscopy-Guided Placement of Central Venous Ports via Internal Jugular Vein: Retrospective Analysis of 1254 Port Implantations at a Single Center

    PubMed Central

    Ahn, Se Jin; Chung, Jin Wook; An, Sang Bu; Yin, Yong Hu; Jae, Hwan Jun; Park, Jae Hyung

    2012-01-01

    Objective To assess the technical success and complication rates of the radiologic placement of central venous ports via the internal jugular vein. Materials and Methods We retrospectively reviewed 1254 central venous ports implanted at our institution between August 2002 and October 2009. All procedures were guided by using ultrasound and fluoroscopy. Catheter maintenance days, technical success rates, peri-procedural, as well as early and late complication rates were evaluated based on the interventional radiologic reports and patient medical records. Results A total of 433386 catheter maintenance days (mean, 350 days; range 0-1165 days) were recorded. The technical success rate was 99.9% and a total of 61 complications occurred (5%), resulting in a post-procedural complication rate of 0.129 of 1000 catheter days. Among them, peri-procedural complications within 24 hours occurred in five patients (0.4%). There were 56 post-procedural complications including 24 (1.9%, 0.055 of 1000 catheter days) early and 32 (2.6%, 0.074 of 1000 catheter days) late complications including, infection (0.6%, 0.018 of 10000 catheter days), thrombotic malfunction (1.4%, 0.040 of 1000 catheter days), nonthrombotic malfunction (0.9%, 0.025 of 1000 catheter days), venous thrombosis (0.5%, 0.014 of 1000 catheter days), as well as wound problems (1.1%, 0.032 of 1000 catheter days). Thirty six CVPs (3%) were removed due to complications. Bloodstream infections and venous thrombosis were the two main adverse events prolonging hospitalization (mean 13 days and 5 days, respectively). Conclusion Radiologic placement of a central venous port via the internal jugular vein is safe and efficient as evidenced by its high technical success rate and a very low complication rate. PMID:22563269

  19. Focused ultrasound guided relocation of kidney stones.

    PubMed

    Abrol, Nitin; Kekre, Nitin S

    2015-01-01

    Complete removal of all fragments is the goal of any intervention for urinary stones. This is more important in lower pole stones where gravity and spatial orientation of lower pole infundibulum may hinder spontaneous passage of fragments. Various adjuvant therapies (inversion, diuresis, percussion, oral citrate, etc.) are described to enhance stone-free rate but are not widely accepted. Focused ultrasound-guided relocation of fragments is a recently described technique aimed at improving results of intervention for stone disease. Purpose of this review is to discuss development of this technology and its potential clinical applications. Pubmed search was made using key words "Focused ultrasound" and "kidney stone". All English language articles were reviewed by title. Relevant studies describing development and application of focused ultrasound in renal stones were selected for review. Focused ultrasound has proven its efficacy in successfully relocating up to 8 mm stone fragments in vitro and in pigs. Relocation is independent of stone composition. The latest model allows imaging and therapy with a single handheld probe facilitating its use by single operator. The acoustic energy delivered by the new prototype is even less than that used for extracorporeal shock wave lithotripsy. Therapeutic exposure has not caused thermal injury in pig kidneys. Focused ultrasound-guided relocation of stones is feasible. Though it is safe in application in pigs, technology is awaiting approval for clinical testing in human beings. This technology has many potential clinical applications in the management of stone disease.

  20. Treatment of great auricular neuralgia with real-time ultrasound-guided great auricular nerve block

    PubMed Central

    Jeon, Younghoon; Kim, Saeyoung

    2017-01-01

    Abstract Rationale: The great auricular nerve can be damaged by the neck surgery, tumor, and long-time pressure on the neck. But, great auricular neuralgia is very rare condition. It was managed by several medication and landmark-based great auricular nerve block with poor prognosis. Patient concerns: A 25-year-old man presented with a pain in the left lateral neck and auricle. Diagnosis: He was diagnosed with great auricular neuralgia. Interventions: His pain was not reduced by medication. Therefore, the great auricular nerve block with local anesthetics and steroid was performed under ultrasound guidance. Outcomes: Ultrasound guided great auricular nerve block alleviated great auricular neuralgia. Lessons: This medication-resistant great auricular neuralgia was treated by the ultrasound guided great auricular nerve block with local anesthetic agent and steroid. Therefore, great auricular nerve block can be a good treatment option of medication resistant great auricular neuralgia. PMID:28328811

  1. MR-guided focused ultrasound: a potentially disruptive technology.

    PubMed

    Bradley, William G

    2009-07-01

    A disruptive technology is a technological innovation that overturns the existing dominant technologies in a market. Magnetic resonance (MR)-guided focused ultrasound (MRgFUS) is a noninvasive procedure based on the combination of real-time MR anatomic guidance, MR thermometry, and high-intensity focused ultrasound. Several hundred transducer elements become convergent at a point under MR guidance, leading to heating and coagulation necrosis. Outside the focal point, there is no significant heating. There is no need to break the skin for procedures in the body or to perform a craniotomy for procedures in the brain. This lack of invasiveness is what makes MRgFUS so disruptive compared with surgery. At present, MRgFUS has been used for the ablation of uterine fibroids, breast tumors, painful bony metastases, and liver tumors. In the brain, it has been used for the ablation of glioblastomas and for functional neurosurgery. Phantom and animal studies suggest future applications for prostate cancer and acute stroke treatment.

  2. Ultrasound-Guided Radiological Placement of Central Venous Port via the Subclavian Vein: A Retrospective Analysis of 500 Cases at a Single Institute

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sakamoto, Noriaki, E-mail: nosakamoto@hotmail.co.jp; Arai, Yasuaki, E-mail: arai-y3111@mvh.biglobe.ne.jp; Takeuchi, Yoshito, E-mail: yostakeu@ncc.go.jp

    2010-10-15

    The purpose of this study was to assess the technical success rate and adverse events (AEs) associated with ultrasound (US)-guided radiological placement (RP) of a central venous port (CVP) via the subclavian vein (SCV). Between April 2006 and May 2007, a total of 500 US-guided RPs of a CVP via the SCV were scheduled in 486 cancer patients (mean age {+-} SD, 54.1 {+-} 18.1 years) at our institute. Referring to the interventional radiology report database and patients' records, technical success rate and AEs relevant to CVP placement were evaluated retrospectively. The technical success rate was 98.6% (493/500). AEs occurredmore » in 26 cases (5.2%) during follow-up (range, 1-1080 days; mean {+-} SD, 304.0 {+-} 292.1 days). AEs within 24 h postprocedure occurred in five patients: pneumothorax (n = 2), arterial puncture (n = 1), hematoma formation at the pocket site (n = 2), and catheter tip migration into the internal mammary vein (n = 1). There were seven early AEs: hematoma formation at the pocket site (n = 2), fibrin sheath formation around the indwelling catheter (n = 2), and catheter-related infections (n = 3). There were 13 delayed AEs: catheter-related infections (n = 7), catheter detachments (n = 3), catheter occlusion (n = 1), symptomatic thrombus in the SCV (n = 1), and catheter migration (n = 1). No major AEs, such as procedure-related death, air embolism, or events requiring surgical intervention, were observed. In conclusion, US-guided RP of a CVP via the SCV is highly appropriate, based on its high technical success rate and the limited number of AEs.« less

  3. Pregnancies following ultrasound-guided drainage of tubo-ovarian abscess.

    PubMed

    Gjelland, Knut; Granberg, Seth; Kiserud, Torvid; Wentzel-Larsen, Tore; Ekerhovd, Erling

    2012-07-01

    To study fertility among women treated by means of ultrasound-guided drainage and antibiotics for tubo-ovarian abscess (TOA). Retrospective cohort study. A tertiary referral center. One hundred women of reproductive age treated for TOA between June 1986 and July 2003. Transvaginal ultrasound-guided drainage of TOA was performed in all patients. The procedure was repeated if a substantial amount of pus was seen using ultrasonography 2-5 days after the initial aspiration, and repeated later if necessary. Frequency of naturally conceived pregnancies. Twenty of 38 (52.6%; 95% CI 36.5-68.9%) women who intended to have a child achieved pregnancy naturally and became mothers. In addition, 7 (50%) of 14 women who were not on birth control on a regular basis became pregnant. No ectopic pregnancies were registered. Ultrasound-guided drainage of TOA in combination with antibiotics seems to preserve fertility in approximately half of the patients. Copyright © 2012 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  4. Magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) ablation of liver tumours.

    PubMed

    Wijlemans, J W; Bartels, L W; Deckers, R; Ries, M; Mali, W P Th M; Moonen, C T W; van den Bosch, M A A J

    2012-09-28

    Recent decades have seen a paradigm shift in the treatment of liver tumours from invasive surgical procedures to minimally invasive image-guided ablation techniques. Magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) is a novel, completely non-invasive ablation technique that has the potential to change the field of liver tumour ablation. The image guidance, using MR imaging and MR temperature mapping, provides excellent planning images and real-time temperature information during the ablation procedure. However, before clinical implementation of MR-HIFU for liver tumour ablation is feasible, several organ-specific challenges have to be addressed. In this review we discuss the MR-HIFU ablation technique, the liver-specific challenges for MR-HIFU tumour ablation, and the proposed solutions for clinical translation.

  5. Magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) ablation of liver tumours

    PubMed Central

    Bartels, L.W.; Deckers, R.; Ries, M.; Mali, W.P.Th.M.; Moonen, C.T.W.; van den Bosch, M.A.A.J.

    2012-01-01

    Abstract Recent decades have seen a paradigm shift in the treatment of liver tumours from invasive surgical procedures to minimally invasive image-guided ablation techniques. Magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) is a novel, completely non-invasive ablation technique that has the potential to change the field of liver tumour ablation. The image guidance, using MR imaging and MR temperature mapping, provides excellent planning images and real-time temperature information during the ablation procedure. However, before clinical implementation of MR-HIFU for liver tumour ablation is feasible, several organ-specific challenges have to be addressed. In this review we discuss the MR-HIFU ablation technique, the liver-specific challenges for MR-HIFU tumour ablation, and the proposed solutions for clinical translation. PMID:23022541

  6. A pitfall during endobronchial ultrasound-guided transbronchial forceps biopsy of the mediastinal lymph nodes.

    PubMed

    Krenke, Rafal; Korczynski, Piotr; Gorska, Katarzyna; Chazan, Ryszarda

    2014-03-01

    The high diagnostic yield and favorable safety profile of endobronchial ultrasound-guided transbronchial forceps biopsy of the mediastinal lymph nodes have been recently demonstrated. We report an unusual technical problem during endobronchial ultrasound-guided transbronchial forceps biopsy that could be a prerequisite for severe complications. A rupture of the steering band precluded closure of the forceps jaws opened in the subcarinal lymph node. A solution to the problem is presented, together with other procedure-related complications reported in the literature. The report emphasizes that a dysfunction of the forceps steering band can result in severe complications when it occurs during transbronchial sampling of mediastinal lesions. Copyright © 2014 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  7. Techniques for Interventional MRI Guidance in Closed-Bore Systems.

    PubMed

    Busse, Harald; Kahn, Thomas; Moche, Michael

    2018-02-01

    Efficient image guidance is the basis for minimally invasive interventions. In comparison with X-ray, computed tomography (CT), or ultrasound imaging, magnetic resonance imaging (MRI) provides the best soft tissue contrast without ionizing radiation and is therefore predestined for procedural control. But MRI is also characterized by spatial constraints, electromagnetic interactions, long imaging times, and resulting workflow issues. Although many technical requirements have been met over the years-most notably magnetic resonance (MR) compatibility of tools, interventional pulse sequences, and powerful processing hardware and software-there is still a large variety of stand-alone devices and systems for specific procedures only.Stereotactic guidance with the table outside the magnet is common and relies on proper registration of the guiding grids or manipulators to the MR images. Instrument tracking, often by optical sensing, can be added to provide the physicians with proper eye-hand coordination during their navigated approach. Only in very short wide-bore systems, needles can be advanced at the extended arm under near real-time imaging. In standard magnets, control and workflow may be improved by remote operation using robotic or manual driving elements.This work highlights a number of devices and techniques for different interventional settings with a focus on percutaneous, interstitial procedures in different organ regions. The goal is to identify technical and procedural elements that might be relevant for interventional guidance in a broader context, independent of the clinical application given here. Key challenges remain the seamless integration into the interventional workflow, safe clinical translation, and proper cost effectiveness.

  8. Endoscopic Ultrasound-Guided Vascular Therapy: The Present and the Future

    PubMed Central

    Hall, Philip S.J.; Teshima, Christopher; May, Gary R.; Mosko, Jeffrey D.

    2017-01-01

    Endoscopic ultrasound (EUS) offers access to many intra-abdominal vessels that until now have only been accessible to the surgeon and interventional radiologist. In addition to assisting with diagnostics, this unique access offers the potential for therapeutic intervention for a host of indications. To date, this has had the most clinical impact in the treatment of gastroesophageal varices, with EUS-guided coil and glue application growing in use worldwide. Although randomised controlled trial data is lacking, we discuss the growing body of literature behind EUS-guided therapy in the management of varices. EUS has also been used in specialized centres to assist in non-variceal gastrointestinal bleeding. The treatment of bleeding from Dieulafoy lesions, tumours and pancreatic pseudoaneurysms has all been described. The potential applications of EUS have also extended to the placement of portal vein stents and porto-systemic shunts in animal models. As medicine continues to move to increasingly less invasive interventions, EUS-guided therapies offer substantial promise for the safe and effective delivery of targeted treatment for a widening array of vascular disorders. PMID:28391673

  9. Determination of optimal ultrasound planes for the initialisation of image registration during endoscopic ultrasound-guided procedures.

    PubMed

    Bonmati, Ester; Hu, Yipeng; Gibson, Eli; Uribarri, Laura; Keane, Geri; Gurusami, Kurinchi; Davidson, Brian; Pereira, Stephen P; Clarkson, Matthew J; Barratt, Dean C

    2018-06-01

    Navigation of endoscopic ultrasound (EUS)-guided procedures of the upper gastrointestinal (GI) system can be technically challenging due to the small fields-of-view of ultrasound and optical devices, as well as the anatomical variability and limited number of orienting landmarks during navigation. Co-registration of an EUS device and a pre-procedure 3D image can enhance the ability to navigate. However, the fidelity of this contextual information depends on the accuracy of registration. The purpose of this study was to develop and test the feasibility of a simulation-based planning method for pre-selecting patient-specific EUS-visible anatomical landmark locations to maximise the accuracy and robustness of a feature-based multimodality registration method. A registration approach was adopted in which landmarks are registered to anatomical structures segmented from the pre-procedure volume. The predicted target registration errors (TREs) of EUS-CT registration were estimated using simulated visible anatomical landmarks and a Monte Carlo simulation of landmark localisation error. The optimal planes were selected based on the 90th percentile of TREs, which provide a robust and more accurate EUS-CT registration initialisation. The method was evaluated by comparing the accuracy and robustness of registrations initialised using optimised planes versus non-optimised planes using manually segmented CT images and simulated ([Formula: see text]) or retrospective clinical ([Formula: see text]) EUS landmarks. The results show a lower 90th percentile TRE when registration is initialised using the optimised planes compared with a non-optimised initialisation approach (p value [Formula: see text]). The proposed simulation-based method to find optimised EUS planes and landmarks for EUS-guided procedures may have the potential to improve registration accuracy. Further work will investigate applying the technique in a clinical setting.

  10. Evaluation of a Standardized Program for Training Practicing Anesthesiologists in Ultrasound-Guided Regional Anesthesia Skills.

    PubMed

    Mariano, Edward R; Harrison, T Kyle; Kim, T Edward; Kan, Jack; Shum, Cynthia; Gaba, David M; Ganaway, Toni; Kou, Alex; Udani, Ankeet D; Howard, Steven K

    2015-10-01

    Practicing anesthesiologists have generally not received formal training in ultrasound-guided perineural catheter insertion. We designed this study to determine the efficacy of a standardized teaching program in this population. Anesthesiologists in practice for 10 years or more were recruited and enrolled to participate in a 1-day program: lectures and live-model ultrasound scanning (morning) and faculty-led iterative practice and mannequin-based simulation (afternoon). Participants were assessed and recorded while performing ultrasound-guided perineural catheter insertion at baseline, at midday (interval), and after the program (final). Videos were scored by 2 blinded reviewers using a composite tool and global rating scale. Participants were surveyed every 3 months for 1 year to report the number of procedures, efficacy of teaching methods, and implementation obstacles. Thirty-two participants were enrolled and completed the program; 31 of 32 (97%) completed the 1-year follow-up. Final scores [median (10th-90th percentiles)] were 21.5 (14.5-28.0) of 30 points compared to 14.0 (9.0-20.0) at interval (P < .001 versus final) and 12.0 (8.5-17.5) at baseline (P < .001 versus final), with no difference between interval and baseline. The global rating scale showed an identical pattern. Twelve of 26 participants without previous experience performed at least 1 perineural catheter insertion after training (P < .001). However, there were no differences in the monthly average number of procedures or complications after the course when compared to baseline. Practicing anesthesiologists without previous training in ultrasound-guided regional anesthesia can acquire perineural catheter insertion skills after a 1-day standardized course, but changing clinical practice remains a challenge. © 2015 by the American Institute of Ultrasound in Medicine.

  11. Combined cumulative sum (CUSUM) and chronological environmental analysis as a tool to improve the learning environment for linear-probe endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) trainees: a pilot study.

    PubMed

    Norisue, Yasuhiro; Tokuda, Yasuharu; Juarez, Mayrol; Uchimido, Ryo; Fujitani, Shigeki; Stoeckel, David A

    2017-02-07

    Cumulative sum (CUSUM) analysis can be used to continuously monitor the performance of an individual or process and detect deviations from a preset or standard level of achievement. However, no previous study has evaluated the utility of CUSUM analysis in facilitating timely environmental assessment and interventions to improve performance of linear-probe endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA). The aim of this study was to evaluate the usefulness of combined CUSUM and chronological environmental analysis as a tool to improve the learning environment for EBUS-TBNA trainees. This study was an observational chart review. To determine if performance was acceptable, CUSUM analysis was used to track procedural outcomes of trainees in EBUS-TBNA. To investigate chronological changes in the learning environment, multivariate logistic regression analysis was used to compare several indices before and after time points when significant changes occurred in proficiency. Presence of an additional attending bronchoscopist was inversely associated with nonproficiency (odds ratio, 0.117; 95% confidence interval, 0-0.749; P = 0.019). Other factors, including presence of an on-site cytopathologist and dose of sedatives used, were not significantly associated with duration of nonproficiency. Combined CUSUM and chronological environmental analysis may be useful in hastening interventions that improve performance of EBUS-TBNA.

  12. Value of artisanal simulators to train veterinary students in performing invasive ultrasound-guided procedures.

    PubMed

    Hage, Maria Cristina F N S; Massaferro, Ana Beatriz; Lopes, Érika Rondon; Beraldo, Carolina Mariano; Daniel, Jéssika

    2016-03-01

    Pericardial effusion can lead to cardiac tamponade, which endangers an animal's life. Ultrasound-guided pericardiocentesis is used to remove abnormal liquid; however, it requires technical expertise. In veterinary medical education, the opportunity to teach this procedure to save lives during emergencies is rare; therefore, simulators are recommended for this practice. The present study aimed to create a model that can be made "at home" at low cost for ultrasound-guided pericardiocentesis training and to gather feedback about this model through questionnaires given to the participants. Eighteen professionals and thirty-six students were introduced to the simulator in pairs. After the simulation training session, participants filled out the questionnaire. Participants considered the model strong in the following areas: visualization of the pericardium, the heart, fluid in the pericardium, and fluid decrease during fictitious pericardiocentesis and its realism. They considered the model weak or moderate in the following areas: visualization of the surrounding tissues, difficulty of pericardial puncture, and visualization of the catheter. The professionals classified the realism of the experimental heart as moderate, whereas the undergraduate students classified it as strong. All participants believed that the experimental model could be useful in preparing for a future real situation. This model fulfills the need for a practical, realistic, and cost-effective model for ultrasound-guided pericardiocentesis training. Copyright © 2016 The American Physiological Society.

  13. Image-guided thoracic surgery in the hybrid operation room.

    PubMed

    Ujiie, Hideki; Effat, Andrew; Yasufuku, Kazuhiro

    2017-01-01

    There has been an increase in the use of image-guided technology to facilitate minimally invasive therapy. The next generation of minimally invasive therapy is focused on advancement and translation of novel image-guided technologies in therapeutic interventions, including surgery, interventional pulmonology, radiation therapy, and interventional laser therapy. To establish the efficacy of different minimally invasive therapies, we have developed a hybrid operating room, known as the guided therapeutics operating room (GTx OR) at the Toronto General Hospital. The GTx OR is equipped with multi-modality image-guidance systems, which features a dual source-dual energy computed tomography (CT) scanner, a robotic cone-beam CT (CBCT)/fluoroscopy, high-performance endobronchial ultrasound system, endoscopic surgery system, near-infrared (NIR) fluorescence imaging system, and navigation tracking systems. The novel multimodality image-guidance systems allow physicians to quickly, and accurately image patients while they are on the operating table. This yield improved outcomes since physicians are able to use image guidance during their procedures, and carry out innovative multi-modality therapeutics. Multiple preclinical translational studies pertaining to innovative minimally invasive technology is being developed in our guided therapeutics laboratory (GTx Lab). The GTx Lab is equipped with similar technology, and multimodality image-guidance systems as the GTx OR, and acts as an appropriate platform for translation of research into human clinical trials. Through the GTx Lab, we are able to perform basic research, such as the development of image-guided technologies, preclinical model testing, as well as preclinical imaging, and then translate that research into the GTx OR. This OR allows for the utilization of new technologies in cancer therapy, including molecular imaging, and other innovative imaging modalities, and therefore enables a better quality of life for patients, both during and after the procedure. In this article, we describe capabilities of the GTx systems, and discuss the first-in-human technologies used, and evaluated in GTx OR.

  14. Thyroid Nodules

    MedlinePlus

    ... the thyroid and see if the nodule is solid or filled with fluid (cystic). Although this test cannot tell if the nodule is cancerous, it is very useful to guide the needle to remove (aspirate) cells from nodules. This procedure is called “ultrasound-guided ...

  15. Pulsed cavitational ultrasound for non-invasive chordal cutting guided by real-time 3D echocardiography.

    PubMed

    Villemain, Olivier; Kwiecinski, Wojciech; Bel, Alain; Robin, Justine; Bruneval, Patrick; Arnal, Bastien; Tanter, Mickael; Pernot, Mathieu; Messas, Emmanuel

    2016-10-01

    Basal chordae surgical section has been shown to be effective in reducing ischaemic mitral regurgitation (IMR). Achieving this section by non-invasive mean can considerably decrease the morbidity of this intervention on already infarcted myocardium. We investigated in vitro and in vivo the feasibility and safety of pulsed cavitational focused ultrasound (histotripsy) for non-invasive chordal cutting guided by real-time 3D echocardiography. Experiments were performed on 12 sheep hearts, 5 in vitro on explanted sheep hearts and 7 in vivo on beating sheep hearts. In vitro, the mitral valve (MV) apparatus including basal and marginal chordae was removed and fixed on a holder in a water tank. High-intensity ultrasound pulses were emitted from the therapeutic device (1-MHz focused transducer, pulses of 8 µs duration, peak negative pressure of 17 MPa, repetition frequency of 100 Hz), placed at a distance of 64 mm under 3D echocardiography guidance. In vivo, after sternotomy, the same therapeutic device was applied on the beating heart. We analysed MV coaptation and chordae by real-time 3D echocardiography before and after basal chordal cutting. After sacrifice, the MV apparatus were harvested for anatomical and histological post-mortem explorations to confirm the section of the chordae. In vitro, all chordae were completely cut after a mean procedure duration of 5.5 ± 2.5 min. The procedure duration was found to increase linearly with the chordae diameter. In vivo, the central basal chordae of the anterior leaflet were completely cut. The mean procedure duration was 20 ± 9 min (min = 14, max = 26). The sectioned chordae was visible on echocardiography, and MV coaptation remained normal with no significant mitral regurgitation. Anatomical and histological post-mortem explorations of the hearts confirmed the section of the chordae. Histotripsy guided by 3D echo achieved successfully to cut MV chordae in vitro and in vivo in beating heart. We hope that this technique will open the door in the near future to the non-invasive treatment of functional IMR. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  16. Multiattribute probabilistic prostate elastic registration (MAPPER): Application to fusion of ultrasound and magnetic resonance imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sparks, Rachel, E-mail: rachel.sparks@ucl.ac.uk; Barratt, Dean; Nicolas Bloch, B.

    2015-03-15

    Purpose: Transrectal ultrasound (TRUS)-guided needle biopsy is the current gold standard for prostate cancer diagnosis. However, up to 40% of prostate cancer lesions appears isoechoic on TRUS. Hence, TRUS-guided biopsy has a high false negative rate for prostate cancer diagnosis. Magnetic resonance imaging (MRI) is better able to distinguish prostate cancer from benign tissue. However, MRI-guided biopsy requires special equipment and training and a longer procedure time. MRI-TRUS fusion, where MRI is acquired preoperatively and then aligned to TRUS, allows for advantages of both modalities to be leveraged during biopsy. MRI-TRUS-guided biopsy increases the yield of cancer positive biopsies. Inmore » this work, the authors present multiattribute probabilistic postate elastic registration (MAPPER) to align prostate MRI and TRUS imagery. Methods: MAPPER involves (1) segmenting the prostate on MRI, (2) calculating a multiattribute probabilistic map of prostate location on TRUS, and (3) maximizing overlap between the prostate segmentation on MRI and the multiattribute probabilistic map on TRUS, thereby driving registration of MRI onto TRUS. MAPPER represents a significant advancement over the current state-of-the-art as it requires no user interaction during the biopsy procedure by leveraging texture and spatial information to determine the prostate location on TRUS. Although MAPPER requires manual interaction to segment the prostate on MRI, this step is performed prior to biopsy and will not substantially increase biopsy procedure time. Results: MAPPER was evaluated on 13 patient studies from two independent datasets—Dataset 1 has 6 studies acquired with a side-firing TRUS probe and a 1.5 T pelvic phased-array coil MRI; Dataset 2 has 7 studies acquired with a volumetric end-firing TRUS probe and a 3.0 T endorectal coil MRI. MAPPER has a root-mean-square error (RMSE) for expert selected fiducials of 3.36 ± 1.10 mm for Dataset 1 and 3.14 ± 0.75 mm for Dataset 2. State-of-the-art MRI-TRUS fusion methods report RMSE of 3.06–2.07 mm. Conclusions: MAPPER aligns MRI and TRUS imagery without manual intervention ensuring efficient, reproducible registration. MAPPER has a similar RMSE to state-of-the-art methods that require manual intervention.« less

  17. Intravascular Ultrasound to Guide Percutaneous Coronary Interventions

    PubMed Central

    2006-01-01

    Executive Summary Objective The objective of this health technology policy assessment was to determine the effectiveness and cost-effectiveness of using intravascular ultrasound (IVUS) as an adjunctive imaging tool to coronary angiography for guiding percutaneous coronary interventions. Background Intravascular Ultrasound Intravascular ultrasound is a procedure that uses high frequency sound waves to acquire 3-dimensional images from the lumen of a blood vessel. The equipment for performing IVUS consists of a percutaneous transducer catheter and a console for reconstructing images. IVUS has been used to study the structure of the arterial wall and nature of atherosclerotic plaques, and obtain measurements of the vessel lumen. Its role in guiding stent placement is also being investigated. IVUS is presently not an insured health service in Ontario. Clinical Need Coronary artery disease accounts for approximately 55% of cardiovascular deaths, the leading cause of death in Canada. In Ontario, the annual mortality rate due to ischemic heart disease was 141.8 per 100,000 population between 1995 and 1997. Percutaneous coronary intervention (PCI), a less invasive approach to treating coronary artery disease, is used more frequently than coronary bypass surgery in Ontario. The number of percutaneous coronary intervention procedures funded by the Ontario Ministry of Health and Long-term Care is expected to increase from approximately 17, 780 in 2004/2005 to 22,355 in 2006/2007 (an increase of 26%), with about 95% requiring the placement of one or more stents. Restenosis following percutaneous coronary interventions involving bare metal stents occurs in 15% to 30% of the cases, mainly because of smooth muscle proliferation and migration, and production of extracellular matrix. In-stent restenosis has been linked to suboptimal stent expansion and inadequate lesion coverage, while stent thrombosis has been attributed to incomplete stent-to-vessel wall apposition. Since coronary angiography (the imaging tool used to guide stent placement) has been shown to be inaccurate in assessing optimal stent placement, and IVUS can provide better views of the vessel lumen, the clinical utility of IVUS as an imaging tool adjunctive to coronary angiography in coronary intervention procedures has been explored in clinical studies. Method A systematic review was conducted to answer the following questions: What are the procedure-related complications associated with IVUS? Does IVUS used in conjunction with angiography to guide percutaneous interventions improve patient outcomes compared to angiographic guidance without IVUS? Who would benefit most in terms of clinical outcomes from the use of IVUS adjunctive to coronary angiography in guiding PCIs? What is the effectiveness of IVUS guidance in the context of drug-eluting stents? What is the cost-effectiveness ratio and budget impact of adjunctive IVUS in PCIs in Ontario? A systematic search of databases OVID MEDLINE, EMBASE, MEDLINE In-Process & Other Non-Indexed Citations, The Cochrane Library, and the International Agency for Health Technology Assessment (INAHTA) database for the period beginning in May 2001 until the day of the search, November 4, 2005 yielded 2 systematic reviews, 1 meta-analysis, 6 randomized controlled trials, and 2 non-randomized studies on left main coronary arteries. The quality of the studies ranged from moderate to high. These reports were combined with reports from a previous systematic review for analysis. In addition to qualitative synthesis, pooled analyses of data from randomized controlled studies using a random effect model in the Cochrane Review Manager 4.2 software were conducted when possible. Findings of Literature Review & Analysis Safety Intravascular ultrasound appears to be a safe tool when used in coronary interventions. Periprocedural complications associated with the use of IVUS in coronary interventions ranged from 0.5% in the largest study to 4%. Coronary rupture was reported in 1 study (1/54). Other complications included prolonged spasms of the artery after stenting, dissection, and femoral aneurysm. Effectiveness Based on pooled analyses of data from randomized controlled studies, the use of intravascular ultrasound adjunctive to coronary intervention in percutaneous coronary interventions using bare metal stents yielded the following findings: For lesions predominantly at low risk of restenosis: There were no significant differences in preintervention angiographic minimal lumen diameter between the IVUS-guided and angiography-guided groups. IVUS guidance resulted in a significantly larger mean postintervention angiographic minimal lumen diameter (weighted mean difference of 0.11 mm, P = .0003) compared to angiographic guidance alone. The benefit in angiographic minimal lumen diameter from IVUS guidance was not maintained at 6-month follow-up, when no significant difference in angiographic minimal lumen diameter could be detected between the two arms (weighted mean difference 0.08, P = .13). There were no statistically significant differences in angiographic binary restenosis rates between IVUS-guidance and no IVUS guidance (Odds ratio [OR] 0.87 in favour of IVUS, 95% Confidence Interval [CI] [0.64–1.18], P = 0.37). IVUS guidance resulted in a reduction in the odds of target lesion revascularization (repeat percutaneous coronary intervention or coronary bypass graft) compared to angiographic guidance alone. The reduction was statistically significant at a follow-up period of 6 months to 1 year, and at a follow-up period of 18 month to 2 years (OR 0.52 in favour of IVUS, 95% CI [0.33–0.81], P = .004). Total revascularization rate (either target lesion or target vessel revascularization) was significantly lower for IVUS-guided patients at 18 months to 2.5 years after intervention (OR 0.43 in favour of IVUS, 95% CI [0.29–0.63], p < .0001). There were no statistically significant differences in the odds of death (OR 1.36 in favour of no IVUS, P =0.65) or myocardial infarction (OR 0.95 in favour of IVUS, P = 0.93) between IVUS-guidance and angiographic guidance alone at up to 2.5 years of follow-up The odds of having a major cardiac event (defined as death, myocardial infarction, and target lesion or target vessel revascularization) were significantly lower for patients with IVUS guidance compared to angiographic guidance alone during follow-up periods of up to 2.5 years (OR 0.53, 95% CI [0.36–0.78], P = 0.001). Since there were no significant reductions in the odds of death or myocardial infarction, the reduction in the odds of combined events reflected mainly the reduction in revascularization rates. For lesions at High Risk of Restenosis: There is evidence from one small, randomized controlled trial (n=150) that IVUS-guided percutaneous coronary intervention in long de novo lesions (>20 mm) of native coronary arteries resulted in statistically significant larger minimal lumen Diameter, and statistically significant lower 6-month angiographic binary restenosis rate. Target vessel revascularization rate and the rate of combined events were also significantly reduced at 12 months. A small subgroup analysis of a randomized controlled trial reported no benefit in clinical or angiographic outcomes for IVUS-guided percutaneous coronary interventions in patients with diabetes compared to those guided by angiography. However, due to the nature and size of the analysis, no firm conclusions could be reached. Based on 2 small, prospective, non-randomized controlled studies, IVUS guidance in percutaneous coronary interventions of left main coronary lesions using bare metal stents or drug-eluting stents did not result in any benefits in angiographic or clinical outcomes. These findings need to be confirmed. Interventions Using Drug-Eluting Stents There is presently no evidence on whether the addition of IVUS guidance during the implantation of drug-eluting stents would reduce incomplete stent apposition, or improve the angiographic or clinical outcomes of patients. Ontario-Based Economic Analysis Cost-effectiveness analysis showed that PCIs using IVUS guidance would likely be less costly and more effective than PCIs without IVUS guidance. The upfront cost of adjunctive use of IVUS in PCIs ranged from $1.56 million at 6% uptake to $13.04 million at 50% uptake. Taking into consideration cost avoidance from reduction in revascularization associated with the use of IVUS, a net saving of $0.63 million to $5.2 million is expected. However, since it is uncertain whether the reduction in revascularization rate resulting from the use of IVUS can be generalized to clinical settings in Ontario, further analysis on the budget impact and cost-effectiveness need to be conducted once Ontario-specific revascularization rates are verified. Factors to be Considered in the Ontario Context Applicability of Findings to Ontario The interim analysis of an Ontario field evaluation that compared drug-eluting stents to bare metal stents showed that the revascularization rates in low-risk patients with bare metal stents were much lower in Ontario compared to rates reported in randomized controlled trials (7.2% vs >17 %). Even though IVUS is presently not routinely used in the stenting of low-risk patients in Ontario, the revascularization rates in these patients in Ontario were shown to be lower than those reported for the IVUS groups reported in published studies. Based on this information and previous findings from the Ontario field evaluation on stenting, it is uncertain whether the reduction in revascularization rates from IVUS guidance can be generalized to Ontario. In light of the above findings, it is advisable to validate the reported benefits of IVUS guidance in percutaneous coronary interventions involving bare metal stents in the Ontario context. Licensing Status As of January 16, 2006, Health Canada has licensed 10 intravascular ultrasound imaging systems/catheters for transluminal intervention procedures, most as class 4 medical devices. Current Funding IVUS is presently not an insured procedure under the Ontario Health Insurance Plan and there are no professional fees for this procedure. All costs related to the use of IVUS are covered within hospitals’ global budgets. A single use IVUS catheter costs approximately $900CDN and the procedure adds approximately 20 minutes to 30 minutes to a percutaneous coronary intervention procedure. Diffusion According to an expert consultant, current use of IVUS in coronary interventions in Ontario is probably limited to high-risk cases such as interventions in long lesions, small vessels, and bifurcated lesions for which images from coronary angiography are indeterminate. It was estimated that IVUS is being used in about 6% of all percutaneous coronary interventions at a large Ontario cardiac centre. Expert Opinion IVUS greatly enhances the cardiac interventionists’ ability to visualize and assess high-risk lesions such as long lesions, narrow lesions, and bifurcated lesions that may have indeterminate angiographic images. Information from IVUS in these cases facilitates the choice of the most appropriate approach for the intervention. Conclusion The use of adjunctive IVUS in PCIs using bare metal stents in lesions predominantly at low risk for restenosis had no significant impact on survival, myocardial infarction, or angiographic restenosis rates up to 2.5 years after intervention. The use of IVUS adjunctive to coronary angiography in percutaneous coronary interventions using bare metal stents in lesions predominantly at low risk for restenosis significantly reduced the target lesion and target vessel revascularization at a follow-up period of 18 months to 2.5 years. One small study suggests that adjunctive IVUS in PCIs using bare metal stents in long lesions (>20 mm) significantly improved the 6-month angiographic restenosis rate and one-year target lesion revascularization rate. These results need to be confirmed with large randomized controlled trials. Based on information from the Ontario field evaluation on stenting, it is uncertain whether the reduction in revascularization rate resulting from the use of IVUS in the placement of bare metal stents can be generalized to clinical settings in Ontario. There is presently insufficient evidence available to determine the impact of adjunctive IVUS in percutaneous interventions in high-risk lesions (other than long lesions) or in PCIs using drug-eluting stents. PMID:23074482

  18. Listening to music during transrectal ultrasound-guided prostate biopsy decreases anxiety, pain and dissatisfaction in patients: a pilot randomized controlled trial.

    PubMed

    Chang, Yun Hee; Oh, Tae Hoon; Lee, Jae Whan; Park, Seung Chol; Seo, Ill Young; Jeong, Hee Jong; Kwon, Whi-An

    2015-01-01

    To determine whether listening to music during transrectal ultrasound (TRUS)-guided 12-core needle prostate biopsy decreases anxiety, pain and dissatisfaction among patients and results in a more comfortable and better tolerated procedure. 76 male patients who underwent TRUS-guided prostate biopsy between March 2013 and June 2014 were randomized into the following groups: no music (group I, n = 38) or classical music (group II, n = 38) during the procedure. Before TRUS-guided prostate biopsy, lidocaine gel was instilled into the rectum. Patient anxiety levels were quantified using the State-Trait Anxiety Inventory. A visual analog scale (0-10) was used for self-assessment of satisfaction, discomfort and willingness among patients to have a repeat TRUS-guided prostate biopsy. Demographic characteristics, mean age, procedure duration and procedure indications did not differ statistically between the two groups. The mean anxiety level and mean pain score of group II were significantly lower than those of group I (p = 0.001 and p = 0.003, respectively). Group II also had a significantly higher mean satisfaction score than group I (p = 0.007). Before the procedure, heart rate and systolic blood pressure were similar in groups I and II; however, after the procedure, levels were lower in group II than in group I (heart rate, p = 0.014; systolic blood pressure, p = 0.011). Listening to music during TRUS-guided prostate biopsy significantly reduced patients' feelings of pain, discomfort and dissatisfaction. Music can serve as a simple, inexpensive and effective adjunct to sedation during TRUS-guided prostate biopsy. We recommend playing music during TRUS-guided prostate biopsy. 2014 S. Karger AG, Basel

  19. Remotely Guided Breast Sonography for Long-Term Space Missions: A Case Report and Discussion.

    PubMed

    Silva-Martinez, Jackelynne P; Sorice Genaro, Andreia; Wen, Hui Annie; Glauber, Naama; Russomano, Thais

    2017-12-01

    Space radiation can cause different types of cancers in crewmembers, especially during long-term space missions. To date, a complete bilateral breast ultrasound has not been performed at the International Space Station (ISS). A breast screening imaging technique could be a useful tool for early identification of breast cancer in astronauts. We hypothesized that breast ultrasound performed by a crewmember while being remotely guided by a specialist from the ground could be an essential tool for medical diagnosis in space. This project aimed to test an ultrasound screening protocol for breast tissue using real-time remotely guided telemedicine techniques. One female volunteer, with no previous medical experience, performed a self-scanned bilateral breast ultrasound exam guided by a remote sonographer. Dynamic ultrasound images were collected using a 25 mm broadband linear array transducer. To simulate fluid shift on the volunteer during microgravity, the bed was tilted -6°. Recorded ultrasound images were analyzed by radiologists, comparing the findings with a gold standard. The experiment demonstrated that real-time remotely guided sonography exam is feasible and can yield meaningful clinical results. This case study showed that remotely guided breast ultrasound can be performed and might become an important tool for diagnosis of breast cancer in space missions. The results cannot be generalized based on one subject, and additional research is warranted in this area in addition to its validation on the ISS. This technique, however, has potential for use as part of preventive medicine procedures for long-term space missions at the ISS, and eventually for human settlements on the Moon and Mars.

  20. Ultrasound-Guided Foot and Ankle Procedures.

    PubMed

    Henning, P Troy

    2016-08-01

    This article reviews commonly performed injections about the foot and ankle region. Although not exhaustive in its description of available techniques, general approaches to these procedures are applicable to any injection about the foot and ankle. As much as possible, the procedures described are based on commonly used or published techniques. An in-depth knowledge of the regional anatomy and understanding of different approaches when performing ultrasonography-guided procedures allows clinicians to adapt to any clinical scenario. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Preclinical Feasibility of a Technology Framework for MRI-guided Iliac Angioplasty

    PubMed Central

    Rube, Martin A.; Fernandez-Gutierrez, Fabiola; Cox, Benjamin F.; Holbrook, Andrew B.; Houston, J. Graeme; White, Richard D.; McLeod, Helen; Fatahi, Mahsa; Melzer, Andreas

    2015-01-01

    Purpose Interventional MRI has significant potential for image guidance of iliac angioplasty and related vascular procedures. A technology framework with in-room image display, control, communication and MRI-guided intervention techniques was designed and tested for its potential to provide safe, fast and efficient MRI-guided angioplasty of the iliac arteries. Methods A 1.5T MRI scanner was adapted for interactive imaging during endovascular procedures using new or modified interventional devices such as guidewires and catheters. A perfused vascular phantom was used for testing. Pre-, intra- and post-procedural visualization and measurement of vascular morphology and flow was implemented. A detailed analysis of X-Ray fluoroscopic angiography workflow was conducted and applied. Two interventional radiologists and one physician in training performed 39 procedures. All procedures were timed and analyzed. Results MRI-guided iliac angioplasty procedures were successfully performed with progressive adaptation of techniques and workflow. The workflow, setup and protocol enabled a reduction in table time for a dedicated MRI-guided procedure to 6 min 33 s with a mean procedure time of 9 min 2 s, comparable to the mean procedure time of 8 min 42 s for the standard X-Ray guided procedure. Conclusions MRI-guided iliac vascular interventions were found to be feasible and practical using this framework and optimized workflow. In particular the real-time flow analysis was found to be helpful for pre- and post-interventional assessments. Design optimization of the catheters and in vivo experiments are required before clinical evaluation. PMID:25102933

  2. Alzheimer disease in a mouse model: MR imaging-guided focused ultrasound targeted to the hippocampus opens the blood-brain barrier and improves pathologic abnormalities and behavior.

    PubMed

    Burgess, Alison; Dubey, Sonam; Yeung, Sharon; Hough, Olivia; Eterman, Naomi; Aubert, Isabelle; Hynynen, Kullervo

    2014-12-01

    To validate whether repeated magnetic resonance (MR) imaging-guided focused ultrasound treatments targeted to the hippocampus, a brain structure relevant for Alzheimer disease ( AD Alzheimer disease ), could modulate pathologic abnormalities, plasticity, and behavior in a mouse model. All animal procedures were approved by the Animal Care Committee and are in accordance with the Canadian Council on Animal Care. Seven-month-old transgenic (TgCRND8) (Tg) mice and their nontransgenic (non-Tg) littermates were entered in the study. Mice were treated weekly with MR imaging-guided focused ultrasound in the bilateral hippocampus (1.68 MHz, 10-msec bursts, 1-Hz burst repetition frequency, 120-second total duration). After 1 month, spatial memory was tested in the Y maze with the novel arm prior to sacrifice and immunohistochemical analysis. The data were compared by using unpaired t tests and analysis of variance with Tukey post hoc analysis. Untreated Tg mice spent 61% less time than untreated non-Tg mice exploring the novel arm of the Y maze because of spatial memory impairments (P < .05). Following MR imaging-guided focused ultrasound, Tg mice spent 99% more time exploring the novel arm, performing as well as their non-Tg littermates. Changes in behavior were correlated with a reduction of the number and size of amyloid plaques in the MR imaging-guided focused ultrasound-treated animals (P < .01). Further, after MR imaging-guided focused ultrasound treatment, there was a 250% increase in the number of newborn neurons in the hippocampus (P < .01). The newborn neurons had longer dendrites and more arborization after MR imaging-guided focused ultrasound, as well (P < .01). Repeated MR imaging-guided focused ultrasound treatments led to spatial memory improvement in a Tg mouse model of AD Alzheimer disease . The behavior changes may be mediated by decreased amyloid pathologic abnormalities and increased neuronal plasticity. © RSNA, 2014.

  3. Ultrasound in Arthritis.

    PubMed

    Sudoł-Szopińska, Iwona; Schueller-Weidekamm, Claudia; Plagou, Athena; Teh, James

    2017-09-01

    Ultrasound is currently performed in everyday rheumatologic practice. It is used for early diagnosis, to monitor treatment results, and to diagnose remission. The spectrum of pathologies seen in arthritis with ultrasound includes early inflammatory features and associated complications. This article discusses the spectrum of ultrasound features of arthritides seen in rheumatoid arthritis and other connective tissue diseases in adults, such as Sjögren syndrome, lupus erythematosus, dermatomyositis, polymyositis, and juvenile idiopathic arthritis. Ultrasound findings in spondyloarthritis, osteoarthritis, and crystal-induced diseases are presented. Ultrasound-guided interventions in patients with arthritis are listed, and the advantages and disadvantages of ultrasound are discussed. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. sFlt-1/PlGF ratio test for pre-eclampsia: an economic assessment for the UK.

    PubMed

    Vatish, M; Strunz-McKendry, T; Hund, M; Allegranza, D; Wolf, C; Smare, C

    2016-12-01

    To assess the economic impact of introducing into clinical practice in the UK the soluble fms-like tyrosine kinase (sFlt-1) to placental growth factor (PlGF) ratio test for guiding the management of pre-eclampsia. We used an economic model estimating the incremental value of information, from a UK National Health Service payer's perspective, generated by the sFlt-1/PlGF ratio test, compared with current diagnostic procedures, in guiding the management of women with suspected pre-eclampsia. The economic model estimated costs associated with the diagnosis and management of pre-eclampsia in pregnant women between 24 + 0 and 36 + 6 weeks' gestation, managed in either a 'test' scenario in which the sFlt-1/PlGF test is used in addition to current diagnostic procedures, or a 'no-test' scenario in which clinical decisions are based on current diagnostic procedures alone. Test characteristics and resource use were derived from PROGNOSIS, a non-interventional study in women presenting with clinical suspicion of pre-eclampsia. The main outcome measure from the economic model was the cost per patient per episode of care, from first suspicion of pre-eclampsia to birth. Introduction of the sFlt-1/PlGF ratio test into clinical practice is expected to result in cost savings of £344 per patient compared with a no-test scenario. Savings are generated primarily through an improvement in diagnostic accuracy and subsequent reduction in unnecessary hospitalization. Introducing the sFlt-1/PlGF ratio test into clinical practice in the UK was shown to be cost-saving by reducing unnecessary hospitalization of women at low risk of developing pre-eclampsia. In addition, the test ensures that those women at higher risk are identified and managed appropriately. © 2016 Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology. © 2016 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of the International Society of Ultrasound in Obstetrics and Gynecology.

  5. Short-term Clinical Results of Manipulation Under Ultrasound-Guided Brachial Plexus Block in Patients with Idiopathic Frozen Shoulder and Diabetic Secondary Frozen Shoulder.

    PubMed

    Ando, Akira; Hamada, Junichiro; Hagiwara, Yoshihiro; Sekiguchi, Takuya; Koide, Masashi; Itoi, Eiji

    2018-01-01

    This study examined the effectiveness of manipulation under ultrasound-guided brachial plexus block in patients with recalcitrant idiopathic frozen shoulder and diabetic secondary frozen shoulder (diabetic frozen shoulder). Forty-four idiopathic frozen shoulders and 10 diabetic frozen shoulders with failed conservative treatment for at least 3 months were included in this study. The manipulation was performed under ultrasound-guided brachial plexus block and visual analogue scale, range of motion, and Constant scores were measured before manipulation and at the last follow-up examination. No major complications were observed during the procedure. Sufficient improvement was not obtained in two patients during the procedure and to avoid complications, the procedure was discontinued and subsequently arthroscopic capsular release was performed. Visual analogue scale, range of motion towards all directions, and Constant scores were significantly improved after the manipulation in both the idiopathic frozen shoulder and diabetic frozen shoulder groups, however the diabetic group showed inferior results compared with those of the idiopathic group. This manipulation was effective and shortened the duration of symptoms in most of the idiopathic and diabetic frozen shoulders without major complications during the procedure. Diabetic frozen shoulder showed inferior clinical results and difficulty in recovery in range of motion, which indicated that diabetic frozen shoulder should be discussed as a different entity.

  6. The Rectal Administration of Lignocaine Gel and Periprostatic Lignocaine Infiltration During Transrectal Ultrasound-Guided Prostate Biopsy Provides Effective Analgesia

    PubMed Central

    Siddiqui, EJ; Ali, S; Koneru, S

    2006-01-01

    INTRODUCTION Transrectal ultrasound guided prostate needle biopsy (TRUS) is the standard procedure to diagnose or exclude prostate cancer. This procedure can be associated with significant discomfort, both on insertion of the ultrasound probe as well as on taking the biopsy. We evaluated a new technique for pain relief during TRUS biopsy. PATIENTS AND METHODS In Group 1 (n = 60), the biopsies were taken without any analgesia. In Group 2 (n = 60), 11 ml of Instillagel (2% lignocaine) was administered rectally prior to probe insertion and 5 ml of 1% lignocaine periprostatic injection was administered before taking the biopsy. The discomfort encountered during the procedure was graded by the patient on a scale ranging from no discomfort to mild, moderate and severe pain. RESULTS In Group 2, there was a marked reduction in the pain experienced during the procedure. The Chi-squared test for trend showed a significant association between the rectal administration of local anaesthetic gel and reduction in pain on probe insertion (P = 0.0001). There was also a significant association between the use of periprostatic lignocaine injection and reduction in pain on taking the biopsy (P < 0.0001). CONCLUSIONS The use of lignocaine gel prior to probe insertion and periprostatic infiltration of lignocaine before taking the needle biopsy significantly reduces the pain experienced by the patient during TRUS-guided prostate biopsy. PMID:16551424

  7. Fluid collection after partial pancreatectomy: EUS drainage and long-term follow-up.

    PubMed

    Caillol, Fabrice; Godat, Sebastien; Turrini, Olivier; Zemmour, Christophe; Bories, Erwan; Pesenti, Christian; Ratone, Jean Phillippe; Ewald, Jacques; Delpero, Jean Robert; Giovannini, Marc

    2018-03-29

    Postoperative fluid collection due to pancreatic leak is the most frequent complication after pancreatic surgery. Endoscopic ultrasound (EUS)-guided drainage of post-pancreatic surgery fluid collection is the gold standard procedure; however, data on outcomes of this procedure are limited. The primary endpoint of our study was relapse over longterm followup, and the secondary endpoint was the efficiency and safety of EUS-guided drainage of post-pancreatic surgery fluid collection. This retrospective study was conducted at a single center from December 2008 to April 2016. Global morbidity was defined as the occurrence of an event involving additional endoscopic procedures, hospitalization, or interventional radiologic or surgical procedures. EUS-guided drainage was considered a clinical failure if surgery was required to treat a relapse after stent removal. Fortyone patients were included. The technical success rate was 100%. Drainage was considered a clinical success in 93% (39/41) of cases. Additionally, 19 (46%) complications were identified as global morbidity. The duration between surgery and EUS-guided drainage was not a significantly related factor for morbidity rate (P = 0.8); however, bleeding due to arterial injuries (splenic artery and gastroduodenal artery) from salvage drainage procedures occurred within 25 days following the initial surgery. There was no difference in survival between patients with and without complications. No relapse was reported during the followup (median: 44.75 months; range: 29.24 to 65.74 months). EUSguided drainage for post-pancreatic surgery fluid collection was efficient with no relapse during longterm followup. Morbidity rate was independent of the duration between the initial surgery and EUS-guided drainage; however, bleeding risk was likely more important in cases of early drainage.

  8. Comparison of the analgesic efficacy of ultrasound-guided rectus sheath block and local anesthetic infiltration for laparoscopic percutaneous extraperitoneal closure in children.

    PubMed

    Uchinami, Yuka; Sakuraya, Fumika; Tanaka, Nobuhiro; Hoshino, Koji; Mikami, Eri; Ishikawa, Taro; Fujii, Hitomi; Ishikawa, Takehiko; Morimoto, Yuji

    2017-05-01

    Ultrasound-guided rectus sheath block and local anesthetic infiltration are the standard options to improve postoperative pain for children undergoing surgery with a midline incision. However, there is no study comparing the effect of ultrasound-guided rectus sheath block with local anesthetic infiltration for children undergoing laparoscopic surgery. The aim of this trial was to compare the onset of ultrasound-guided rectus sheath block with that of local anesthetic infiltration for laparoscopic percutaneous extraperitoneal closure in children. We performed an observer-blinded, randomized, prospective trial. Enrolled patients were assigned to either an ultrasound-guided rectus sheath block group or a local anesthetic infiltration group. The ultrasound-guided rectus sheath block group (n = 17) received ultrasound-guided rectus sheath block with 0.2 ml·kg -1 of 0.375% ropivacaine per side in the posterior rectus sheath compartment. The local anesthetic infiltration group (n = 17) received local anesthetic infiltration with 0.2 ml·kg -1 of 0.75% ropivacaine. The Face, Legs, Activity, Cry, and Consolability (FLACC) pain scores were recorded at 0, 30, 60 min after arrival at the postanesthesia care unit. Of the 37 patients enrolled in this study, 34 completed the study protocol. A significant difference in the pain scale between the ultrasound-guided rectus sheath block group and local anesthetic infiltration group was found at 0 min (median: 0, interquartile range [IQR]: 0-1.5, vs median: 1, IQR 0-5, confidence interval of median [95% CI]: 0-3, P = 0.048), but no significant difference was found at 30 min (median: 1, IQR: 0-4 vs median: 6, IQR: 0-7, 95% CI: 0-5, P = 0.061), or 60 min (median: 0, IQR: 0-2 vs median: 1, IQR: 0-3, 95% CI: -1 to 1, P = 0.310). No significant difference was found in anesthesia time between the ultrasound-guided rectus sheath block and local anesthetic infiltration groups. No procedure-related complications were observed in either group. Ultrasound-guided rectus sheath block is a quicker way to control postoperative pain for pediatric patients undergoing laparoscopic extraperitoneal closure than local anesthetic infiltration, and thus may provide a clinical benefit. © 2017 John Wiley & Sons Ltd.

  9. Predictors and Long-Term Clinical Impact of Acute Stent Malapposition: An Assessment of Dual Antiplatelet Therapy With Drug-Eluting Stents (ADAPT-DES) Intravascular Ultrasound Substudy.

    PubMed

    Wang, Bin; Mintz, Gary S; Witzenbichler, Bernhard; Souza, Cristiano F; Metzger, D Christopher; Rinaldi, Michael J; Duffy, Peter L; Weisz, Giora; Stuckey, Thomas D; Brodie, Bruce R; Matsumura, Mitsuaki; Yamamoto, Myong-Hwa; Parvataneni, Rupa; Kirtane, Ajay J; Stone, Gregg W; Maehara, Akiko

    2016-12-22

    The impact of acute stent malapposition (ASM) on long-term clinical outcomes in patients undergoing percutaneous coronary intervention is still controversial. We sought to evaluate predictors and long-term clinical outcomes of ASM. ADAPT-DES (Assessment of Dual Antiplatelet Therapy With Drug-Eluting Stents) was a prospective multicenter study of 8663 patients undergoing percutaneous coronary intervention using drug-eluting stents. In a prespecified intravascular ultrasound-guided substudy, 2072 patients with 2446 culprit lesions had post-percutaneous coronary intervention intravascular ultrasound and were classified according to the presence or absence of ASM. After intravascular ultrasound-guided percutaneous coronary intervention, the overall prevalence of ASM after successful drug-eluting stents implantation was 14.4% per patient and 12.6% per lesion. Compared to lesions without ASM, lesions with ASM had larger in-stent lumen areas, larger stent areas, and larger in-stent vessel areas. A larger mean plaque area along with more attenuated plaque was observed in lesions with ASM versus lesions without ASM. Lesions with ASM had greater proximal and distal reference lumen areas and more distal, but not proximal, reference calcium compared to lesions without ASM. At 2-year follow-up, there was no significant difference in the incidence of cardiac death; myocardial infarction; early, late, or very late stent thrombosis; or clinically driven target lesion revascularization in patients with ASM versus those without ASM. Furthermore, ASM was not an independent predictor of 2-year major adverse cardiac events or target lesion revascularization even when forced into the multivariate model. In patients treated with intravascular ultrasound-guided drug-eluting stents implantation, ASM was not associated with adverse clinical events during long-term follow-up including, but not limited to, stent thrombosis. URL: https://www.clinicaltrials.gov. Unique identifier: NCT00638794. © 2016 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  10. Endoscopic ultrasonography guided drainage: Summary of consortium meeting, May 21, 2012, San Diego, California

    PubMed Central

    Kahaleh, Michel; Artifon, Everson LA; Perez-Miranda, Manuel; Gaidhane, Monica; Rondon, Carlos; Itoi, Takao; Giovannini, Marc

    2015-01-01

    Endoscopic retrograde cholangiopancreatography (ERCP) is the preferred procedure for biliary and pancreatic drainage. While ERCP is successful in about 95% of cases, a small subset of cases are unsuccessful due to altered anatomy, peri-ampullary pathology, or malignant obstruction. Endoscopic ultrasound-guided drainage is a promising technique for biliary, pancreatic and recently gallbladder decompression, which provides multiple advantages over percutaneous or surgical biliary drainage. Multiple retrospective and some prospective studies have shown endoscopic ultrasound-guided drainage to be safe and effective. Based on the currently reported literature, regardless of the approach, the cumulative success rate is 84%-93% with an overall complication rate of 16%-35%. endoscopic ultrasound-guided drainage seems a viable therapeutic modality for failed conventional drainage when performed by highly skilled advanced endoscopists at tertiary centers with expertise in both echo-endoscopy and therapeutic endoscopy PMID:25624708

  11. Brief reports: regional anesthesia needles can introduce ultrasound gel into tissues.

    PubMed

    Belavy, David

    2010-09-01

    Anesthesiologists may insert needles through ultrasound gel when performing ultrasound-guided regional anesthesia. In this study, it was determined whether needles carry gel into tissues. Ultrasound gel dyed blue was applied to pork rashers. Tuohy and short-bevel needles were passed through the gel and pork. The needles were then assessed for the presence of ultrasound gel. All needles, including those with stylets, carried gel and tissue within the lumen. Ultrasound gel may be injected around (and perhaps in) nerves during regional anesthesia procedures. Studies are needed to determine the implications of this practice.

  12. Determining procedures for simulation-based training in radiology: a nationwide needs assessment.

    PubMed

    Nayahangan, Leizl Joy; Nielsen, Kristina Rue; Albrecht-Beste, Elisabeth; Bachmann Nielsen, Michael; Paltved, Charlotte; Lindorff-Larsen, Karen Gilboe; Nielsen, Bjørn Ulrik; Konge, Lars

    2018-06-01

    New training modalities such as simulation are widely accepted in radiology; however, development of effective simulation-based training programs is challenging. They are often unstructured and based on convenience or coincidence. The study objective was to perform a nationwide needs assessment to identify and prioritize technical procedures that should be included in a simulation-based curriculum. A needs assessment using the Delphi method was completed among 91 key leaders in radiology. Round 1 identified technical procedures that radiologists should learn. Round 2 explored frequency of procedure, number of radiologists performing the procedure, risk and/or discomfort for patients, and feasibility for simulation. Round 3 was elimination and prioritization of procedures. Response rates were 67 %, 70 % and 66 %, respectively. In Round 1, 22 technical procedures were included. Round 2 resulted in pre-prioritization of procedures. In round 3, 13 procedures were included in the final prioritized list. The three highly prioritized procedures were ultrasound-guided (US) histological biopsy and fine-needle aspiration, US-guided needle puncture and catheter drainage, and basic abdominal ultrasound. A needs assessment identified and prioritized 13 technical procedures to include in a simulation-based curriculum. The list may be used as guide for development of training programs. • Simulation-based training can supplement training on patients in radiology. • Development of simulation-based training should follow a structured approach. • The CAMES Needs Assessment Formula explores needs for simulation training. • A national Delphi study identified and prioritized procedures suitable for simulation training. • The prioritized list serves as guide for development of courses in radiology.

  13. MO-DE-202-03: Image-Guided Surgery and Interventions in the Advanced Multimodality Image-Guided Operating (AMIGO) Suite

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kapur, T.

    At least three major trends in surgical intervention have emerged over the last decade: a move toward more minimally invasive (or non-invasive) approach to the surgical target; the development of high-precision treatment delivery techniques; and the increasing role of multi-modality intraoperative imaging in support of such procedures. This symposium includes invited presentations on recent advances in each of these areas and the emerging role for medical physics research in the development and translation of high-precision interventional techniques. The four speakers are: Keyvan Farahani, “Image-guided focused ultrasound surgery and therapy” Jeffrey H. Siewerdsen, “Advances in image registration and reconstruction for image-guidedmore » neurosurgery” Tina Kapur, “Image-guided surgery and interventions in the advanced multimodality image-guided operating (AMIGO) suite” Raj Shekhar, “Multimodality image-guided interventions: Multimodality for the rest of us” Learning Objectives: Understand the principles and applications of HIFU in surgical ablation. Learn about recent advances in 3D–2D and 3D deformable image registration in support of surgical safety and precision. Learn about recent advances in model-based 3D image reconstruction in application to intraoperative 3D imaging. Understand the multi-modality imaging technologies and clinical applications investigated in the AMIGO suite. Understand the emerging need and techniques to implement multi-modality image guidance in surgical applications such as neurosurgery, orthopaedic surgery, vascular surgery, and interventional radiology. Research supported by the NIH and Siemens Healthcare.; J. Siewerdsen; Grant Support - National Institutes of Health; Grant Support - Siemens Healthcare; Grant Support - Carestream Health; Advisory Board - Carestream Health; Licensing Agreement - Carestream Health; Licensing Agreement - Elekta Oncology.; T. Kapur, P41EB015898; R. Shekhar, Funding: R42CA137886 and R41CA192504 Disclosure and CoI: IGI Technologies, small-business partner on the grants.« less

  14. Application of Ultrasound-Guided Core Biopsy to Minimal-Invasively Diagnose Supraclavicular Fossa Tumors and Minimize the Requirement of Invasive Diagnostic Surgery

    PubMed Central

    Chen, Chun-Nan; Lin, Che-Yi; Chi, Fan-Hsiang; Chou, Chen-Han; Hsu, Ya-Ching; Kuo, Yen-Lin; Lin, Chih-Feng; Chen, Tseng-Cheng; Wang, Cheng-Ping; Lou, Pei-Jen; Ko, Jenq-Yuh; Hsiao, Tzu-Yu; Yang, Tsung-Lin

    2016-01-01

    Abstract Tumors of the supraclavicular fossa (SC) is clinically challenging because of anatomical complexity and tumor pathological diversity. Because of varied diseases entities and treatment choices of SC tumors, making the accurate decision among numerous differential diagnoses is imperative. Sampling by open biopsy (OB) remains the standard procedure for pathological confirmation. However, complicated anatomical structures of SC always render surgical intervention difficult to perform. Ultrasound-guided core biopsy (USCB) is a minimally invasive and office-based procedure for tissue sampling widely applied in many diseases of head and neck. This study aims to evaluate the clinical efficacy and utility of using USCB as the sampling method of SC tumors. From 2009 to 2014, consecutive patients who presented clinical symptoms and signs of supraclavicular tumors and were scheduled to receive sampling procedures for diagnostic confirmation were recruited. The patients received USCB or OB respectively in the initial tissue sampling. The accurate diagnostic rate based on pathological results was 90.2% for USCB, and 93.6% for OB. No significant difference was noted between USCB and OB groups in terms of diagnostic accuracy and the percentage of inadequate specimens. All cases in the USCB group had the sampling procedure completed within 10 minutes, but not in the OB group. No scars larger than 1 cm were found in USCB. Only patients in the OB groups had the need to receive general anesthesia and hospitalization and had scars postoperatively. Accordingly, USCB can serve as the first-line sampling tool for SC tumors with high diagnostic accuracy, minimal invasiveness, and low medical cost. PMID:26825877

  15. Ultrasound-guided percutaneous irrigation in rotator cuff calcific tendinopathy: what is the evidence? A systematic review with proposals for future reporting.

    PubMed

    Lanza, Ezio; Banfi, Giuseppe; Serafini, Giovanni; Lacelli, Francesca; Orlandi, Davide; Bandirali, Michele; Sardanelli, Francesco; Sconfienza, Luca Maria

    2015-07-01

    We performed a systematic review of current evidence regarding ultrasound-guided percutaneous irrigation of calcific tendinopathy (US-PICT) in the shoulder aimed to: assess different published techniques; evaluate clinical outcome in a large combined cohort; and propose suggestions for homogeneous future reporting. Cochrane Collaboration for Systematic Reviews of Interventions Guidelines were followed. We searched MEDLINE/MEDLINE In-Process/EMBASE/Cochrane databases from 1992-2013 using the keywords 'ultrasound, shoulder, needling, calcification, lavage, rotator cuff' combined in appropriate algorithms. References of resulting papers were also screened. Risk of bias was assessed with a modified Newcastle-Ottawa Scale. Of 284 papers found, 15 were included, treating 1,450 shoulders in 1,403 patients (females, n = 838; mean age interval 40-63 years). There was no exclusion due to risk of bias. US-PICT of rotator cuff is a safe and effective procedure, with an estimated average 55% pain improvement at an average of 11 months, with a 10% minor complication rate. No evidence exists in favour of using a specific size/number of needles. Imaging follow-up should not be used routinely. Future studies should aim at structural uniformity, including the use of the Constant Score to assess outcomes and 1-year minimum follow-up. Alternatives to steroid injections should also be explored. • US-PICT of rotator cuff is a safe and effective procedure. • On average 55% pain improvement with 10% minor complication rate. • No evidence exists in favour of using a specific size/number of needles. • Future need to assess outcome using Constant Score with 1-year minimum follow-up.

  16. Diaphragm-Sparing Nerve Blocks for Shoulder Surgery.

    PubMed

    Tran, De Q H; Elgueta, Maria Francisca; Aliste, Julian; Finlayson, Roderick J

    Shoulder surgery can result in significant postoperative pain. Interscalene brachial plexus blocks (ISBs) constitute the current criterion standard for analgesia but may be contraindicated in patients with pulmonary pathology due to the inherent risk of phrenic nerve block and symptomatic hemidiaphragmatic paralysis. Although ultrasound-guided ISB with small volumes (5 mL), dilute local anesthetic (LA) concentrations, and LA injection 4 mm lateral to the brachial plexus have been shown to reduce the risk of phrenic nerve block, no single intervention can decrease its incidence below 20%. Ultrasound-guided supraclavicular blocks with LA injection posterolateral to the brachial plexus may anesthetize the shoulder without incidental diaphragmatic dysfunction, but further confirmatory trials are required. Ultrasound-guided C7 root blocks also seem to offer an attractive, diaphragm-sparing alternative to ISB. However, additional large-scale studies are needed to confirm their efficacy and to quantify the risk of periforaminal vascular breach. Combined axillary-suprascapular nerve blocks may provide adequate postoperative analgesia for minor shoulder surgery but do not compare favorably to ISB for major surgical procedures. One intriguing solution lies in the combined use of infraclavicular brachial plexus blocks and suprascapular nerve blocks. Theoretically, the infraclavicular approach targets the posterior and lateral cords, thus anesthetizing the axillary nerve (which supplies the anterior and posterior shoulder joint), as well as the subscapular and lateral pectoral nerves (both of which supply the anterior shoulder joint), whereas the suprascapular nerve block anesthetizes the posterior shoulder. Future randomized trials are required to validate the efficacy of combined infraclavicular-suprascapular blocks for shoulder surgery.

  17. Ultrasound-Guided Elbow Procedures.

    PubMed

    Sussman, Walter I; Williams, Christopher J; Mautner, Ken

    2016-08-01

    High-resolution ultrasonography can help clinicians visualize key anatomic structures of the elbow and guide periarticular and intra-articular injections. Historically, most procedures done around the elbow have been done using landmark guidance, and few studies have reported the accuracy of ultrasonography-guided injections in the elbow region. This article reviews common musculoskeletal disorders about the elbow that can be evaluated with ultrasonography, reviews the literature on ultrasonography-guided injections of the elbow region, and describes the senior author's preferred approach for the most commonly performed elbow region injections. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Accuracy of non-operative identification of the sentinel lymph node using combined gamma and ultrasound scanning.

    PubMed

    Whelehan, P; Vinnicombe, S J; Brown, D C; McLean, D; Evans, A

    2014-08-01

    To assess how accurately the sentinel lymph node (SLN) can be identified percutaneously, using gamma probe and ultrasound technology. Women with breast cancer, scheduled for wide local excision or mastectomy with SLN biopsy (SLNB), were included. Peri-areolar intradermal injection of technetium-99 nanocolloid was performed on the morning of surgery and 1-2 ml of blue dye was injected in the peri-areolar region once the patient was anaesthetized. Prior to surgery, a gamma probe was used over the skin to identify any hot spot that could represent a SLN. Ultrasound, guided by the hot spot, was then used to visualize potential SLNs and guide the insertion of a localizing wire. The accuracy in localizing the SLN by preoperative gamma-probe guided ultrasonography was assessed by comparison to SLNB. A SLN was correctly identified and marked using gamma-probe guided ultrasonography in 44 of 59 cases (75%; 95% CI: 63-86%). This study supports the case for investigating percutaneous gamma probe and ultrasound guided interventions in the axilla in women with breast cancer, as a potential alternative to surgical SLNB. Copyright © 2014 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  19. Objective assessment of operator performance during ultrasound-guided procedures.

    PubMed

    Tabriz, David M; Street, Mandie; Pilgram, Thomas K; Duncan, James R

    2011-09-01

    Simulation permits objective assessment of operator performance in a controlled and safe environment. Image-guided procedures often require accurate needle placement, and we designed a system to monitor how ultrasound guidance is used to monitor needle advancement toward a target. The results were correlated with other estimates of operator skill. The simulator consisted of a tissue phantom, ultrasound unit, and electromagnetic tracking system. Operators were asked to guide a needle toward a visible point target. Performance was video-recorded and synchronized with the electromagnetic tracking data. A series of algorithms based on motor control theory and human information processing were used to convert raw tracking data into different performance indices. Scoring algorithms converted the tracking data into efficiency, quality, task difficulty, and targeting scores that were aggregated to create performance indices. After initial feasibility testing, a standardized assessment was developed. Operators (N = 12) with a broad spectrum of skill and experience were enrolled and tested. Overall scores were based on performance during ten simulated procedures. Prior clinical experience was used to independently estimate operator skill. When summed, the performance indices correlated well with estimated skill. Operators with minimal or no prior experience scored markedly lower than experienced operators. The overall score tended to increase according to operator's clinical experience. Operator experience was linked to decreased variation in multiple aspects of performance. The aggregated results of multiple trials provided the best correlation between estimated skill and performance. A metric for the operator's ability to maintain the needle aimed at the target discriminated between operators with different levels of experience. This study used a highly focused task model, standardized assessment, and objective data analysis to assess performance during simulated ultrasound-guided needle placement. The performance indices were closely related to operator experience.

  20. Endoscopic Ultrasound-Guided Management of Pancreatic Fluid Collections: Update and Review of the Literature

    PubMed Central

    Alali, Ali; Mosko, Jeffrey; May, Gary; Teshima, Christopher

    2017-01-01

    Severe acute pancreatitis is often complicated by the development of pancreatic fluid collections (PFCs), which may be associated with significant morbidity and mortality. It is crucial to accurately classify these collections as a pseudocyst or walled-off necrosis (WON) given significant differences in outcomes and management. Interventions for PFCs have increasingly shifted to less invasive strategies, with endoscopic ultrasound (EUS)-guided methods being shown to be safer and equally effective as more invasive surgical techniques. In recent years, many new developments have improved the safety and efficacy of EUS-guided interventions, such as the introduction of lumen-apposing metal stents (LAMS), direct endoscopic necrosectomy (DEN) and multiple other adjunctive techniques. Despite these developments, treatment of PFCs, and infected WON in particular, continues to be associated with significant morbidity and mortality. In this article, we discuss the EUS-guided management of PFCs while reviewing the latest developments and controversies in the field. We end by summarizing our own approach to managing PFCs. PMID:28391671

  1. Ultrasound criteria and guided fine-needle aspiration diagnostic yields in small animal peritoneal, mesenteric and omental disease.

    PubMed

    Feeney, Daniel A; Ober, Christopher P; Snyder, Laura A; Hill, Sara A; Jessen, Carl R

    2013-01-01

    Peritoneal, mesenteric, and omental diseases are important causes of morbidity and mortality in humans and animals, although information in the veterinary literature is limited. The purposes of this retrospective study were to determine whether objectively applied ultrasound interpretive criteria are statistically useful in differentiating among cytologically defined normal, inflammatory, and neoplastic peritoneal conditions in dogs and cats. A second goal was to determine the cytologically interpretable yield on ultrasound-guided, fine-needle sampling of peritoneal, mesenteric, or omental structures. Sonographic criteria agreed upon by the authors were retrospectively and independently applied by two radiologists to the available ultrasound images without knowledge of the cytologic diagnosis and statistically compared to the ultrasound-guided, fine-needle aspiration cytologic interpretations. A total of 72 dogs and 49 cats with abdominal peritoneal, mesenteric, or omental (peritoneal) surface or effusive disease and 17 dogs and 3 cats with no cytologic evidence of inflammation or neoplasia were included. The optimized, ultrasound criteria-based statistical model created independently for each radiologist yielded an equation-based diagnostic category placement accuracy of 63.2-69.9% across the two involved radiologists. Regional organ-associated masses or nodules as well as aggregated bowel and peritoneal thickening were more associated with peritoneal neoplasia whereas localized, severely complex fluid collections were more associated with inflammatory peritoneal disease. The cytologically interpretable yield for ultrasound-guided fine-needle sampling was 72.3% with no difference between species, making this a worthwhile clinical procedure. © 2013 Veterinary Radiology & Ultrasound.

  2. Reduced-dose C-arm computed tomography applications at a pediatric institution.

    PubMed

    Acord, Michael; Shellikeri, Sphoorti; Vatsky, Seth; Srinivasan, Abhay; Krishnamurthy, Ganesh; Keller, Marc S; Cahill, Anne Marie

    2017-12-01

    Reduced-dose C-arm computed tomography (CT) uses flat-panel detectors to acquire real-time 3-D images in the interventional radiology suite to assist with anatomical localization and procedure planning. To describe dose-reduction techniques for C-arm CT at a pediatric institution and to provide guidance for implementation. We conducted a 5-year retrospective study on procedures using an institution-specific reduced-dose protocol: 5 or 8 s Dyna Rotation, 248/396 projection images/acquisition and 0.1-0.17 μGy/projection dose at the detector with 0.3/0.6/0.9-mm copper (Cu) filtration. We categorized cases by procedure type and average patient age and calculated C-arm CT and total dose area product (DAP). Two hundred twenty-two C-arm CT-guided procedures were performed with a dose-reduction protocol. The most common procedures were temporomandibular and sacroiliac joint injections (48.6%) and sclerotherapy (34.2%). C-arm CT was utilized in cases of difficult percutaneous access in less common applications such as cecostomy and gastrostomy placement, foreign body retrieval and thoracentesis. C-arm CT accounted for between 9.9% and 80.7% of the total procedural DAP. Dose-reducing techniques can preserve image quality for intervention while reducing radiation exposure to the child. This technology has multiple applications within pediatric interventional radiology and can be considered as an adjunctive imaging tool in a variety of procedures, particularly when percutaneous access is challenging despite routine fluoroscopic or ultrasound guidance.

  3. Endoscopic ultrasound-guided pancreaticobiliary intervention in patients with surgically altered anatomy and inaccessible papillae: A review of current literature

    PubMed Central

    Martin, Aaron; Kistler, Charles Andrew; Wrobel, Piotr; Yang, Juliana F.; Siddiqui, Ali A.

    2016-01-01

    The management of pancreaticobiliary disease in patients with surgically altered anatomy is a growing problem for gastroenterologists today. Over the years, endoscopic ultrasound (EUS) has emerged as an important diagnostic and therapeutic modality in the treatment of pancreaticobiliary disease. Patient anatomy has become increasingly complex due to advances in surgical resection of pancreaticobiliary disease and EUS has emerged as the therapy of choice when endoscopic retrograde cholangiopancreatography failed cannulation or when the papilla is inaccessible such as in gastric obstruction or duodenal obstruction. The current article gives a comprehensive review of the current literature for EUS-guided intervention of the pancreaticobiliary tract in patients with altered surgical anatomy. PMID:27386471

  4. Real-Time Integrated Photoacoustic and Ultrasound (PAUS) Imaging System to Guide Interventional Procedures: Ex Vivo Study

    PubMed Central

    Wei, Chen-Wei; Nguyen, Thu-Mai; Xia, Jinjun; Arnal, Bastien; Wong, Emily Y.; Pelivanov, Ivan M.; O’Donnell, Matthew

    2015-01-01

    Because of depth-dependent light attenuation, bulky, low-repetition-rate lasers are usually used in most photoacoustic (PA) systems to provide sufficient pulse energies to image at depth within the body. However, integrating these lasers with real-time clinical ultrasound (US) scanners has been problematic because of their size and cost. In this paper, an integrated PA/US (PAUS) imaging system is presented operating at frame rates >30 Hz. By employing a portable, low-cost, low-pulse-energy (~2 mJ/pulse), high-repetition-rate (~1 kHz), 1053-nm laser, and a rotating galvo-mirror system enabling rapid laser beam scanning over the imaging area, the approach is demonstrated for potential applications requiring a few centimeters of penetration. In particular, we demonstrate here real-time (30 Hz frame rate) imaging (by combining multiple single-shot sub-images covering the scan region) of an 18-gauge needle inserted into a piece of chicken breast with subsequent delivery of an absorptive agent at more than 1-cm depth to mimic PAUS guidance of an interventional procedure. A signal-to-noise ratio of more than 35 dB is obtained for the needle in an imaging area 2.8 × 2.8 cm (depth × lateral). Higher frame rate operation is envisioned with an optimized scanning scheme. PMID:25643081

  5. Endobronchial ultrasound-guided transbronchial needle injection for local control of recurrent non-small cell lung cancer.

    PubMed

    Khan, Farrah; Anker, Christopher J; Garrison, Garth; Kinsey, C Matthew

    2015-01-01

    Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is an established technique for the diagnosis of thoracic malignancies. Non-ultrasound-guided transbronchial needle injection has been used previously to deliver chemotherapeutic agents. To use endobronchial ultrasound-guided transbronchial needle injection (EBUS-TBNI) to achieve local control of recurrent early-stage lung cancer. A 63-year-old man presented with recurrent early stage non-small cell lung carcinoma after chemotherapy and external beam radiation. We used EBUS-TBNI to deliver cisplatin into the tumor located outside the airway. This procedure was performed on three separate occasions without complication. EBUS-TBNI resulted in resolution of fluorodeoxyglucose avidity, measured by positron emission tomography-computed tomography, in the region at 4 weeks. However, at 5 months, there was evidence of distal recurrence. This is the first description of EBUS-TBNI to treat local recurrence of lung cancer and one of the first reports of the use of EBUS for intratumoral therapy. Additional research is warranted to determine the clinical usefulness and safety of this therapeutic approach.

  6. Interventional therapeutic procedures in the musculoskeletal system: an Italian Survey by the Italian College of Musculoskeletal Radiology.

    PubMed

    Silvestri, Enzo; Barile, Antonio; Albano, Domenico; Messina, Carmelo; Orlandi, Davide; Corazza, Angelo; Zugaro, Luigi; Masciocchi, Carlo; Sconfienza, Luca Maria

    2018-04-01

    To perform an online survey among all members of the Italian College of Musculoskeletal Radiology to understand how therapeutic musculoskeletal procedures are performed in daily practice in Italy. We administered an online survey to all 2405 members about the use of therapeutic musculoskeletal procedures in their institutions asking 16 different questions. Subgroup analysis was performed between general and orthopaedic hospitals with Mann-Whitney U and χ 2 statistics. A total of 129/2405 answers (5.4% of members) were included in our analysis. A median of 142.5 (25th-75th percentiles: 50-535.5; range 10-5000) therapeutic musculoskeletal procedures per single institution was performed in 2016. Arthropathic pain was the main indication. The most common procedures were joint injection, bursal/tendon injection, and irrigation of calcific tendinopathy. Ultrasound-guided procedures were mainly performed in ultrasonography rooms (77.4%) rather than in dedicated interventional rooms (22.6%). Conversely, fluoroscopic procedures were performed almost with the same frequency in interventional radiology suites (52.4%) and in general radiology rooms (47.6%). In most institutions (72%), autologous blood or components were not used. The median number of therapeutic musculoskeletal procedures performed in orthopaedic hospitals was significantly higher than in general hospitals (P = 0.002), as well as for the use of autologous preparations (P = 0.004). Joint injection, bursal/tendon injection, and irrigation of calcific tendinopathy were the most common therapeutic musculoskeletal procedures, being arthropathic pain the main indication. The percentage of procedures and the use of autologous preparations were significantly higher in orthopaedic hospitals than in general hospitals.

  7. Electromagnetic-Tracked Biopsy under Ultrasound Guidance: Preliminary Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hakime, Antoine, E-mail: thakime@yahoo.com; Deschamps, Frederic; Marques De Carvalho, Enio Garcia

    2012-08-15

    Purpose: This study was designed to evaluate the accuracy and safety of electromagnetic needle tracking for sonographically guided percutaneous liver biopsies. Methods: We performed 23 consecutive ultrasound-guided liver biopsies for liver nodules with an electromagnetic tracking of the needle. A sensor placed at the tip of a sterile stylet (18G) inserted in a coaxial guiding trocar (16G) used for biopsy was localized in real time relative to the ultrasound imaging plane, thanks to an electromagnetic transmitter and two sensors on the ultrasound probe. This allows for electronic display of the needle tip location and the future needle path overlaid onmore » the real-time ultrasound image. Distance between needle tip position and its electronic display, number of needle punctures, number of needle pull backs for redirection, technical success (needle positioned in the target), diagnostic success (correct histopathology result), procedure time, and complication were evaluated according to lesion sizes, depth and location, operator experience, and 'in-plane' or 'out-of-plane' needle approach. Results: Electronic display was always within 2 mm from the real position of the needle tip. The technical success rate was 100%. A single needle puncture without repuncture was used in all patients. Pull backs were necessary in six patients (26%) to obtain correct needle placement. The overall diagnostic success rate was 91%. The overall true-positive, true-negative, false-negative, and failure rates of the biopsy were 100% (19/19) 100% (2/2), 0% (0/23), and 9% (2/23). The median total procedure time from the skin puncture to the needle in the target was 30 sec (from 5-60 s). Lesion depth and localizations, operator experience, in-plane or out-of-plane approach did not affect significantly the technical, diagnostic success, or procedure time. Even when the tumor size decreased, the procedure time did not increase. Conclusions: Electromagnetic-tracked biopsy is accurate to determine needle tip position and allows fast and accurate needle placement in targeted liver nodules.« less

  8. Evaluation of hospital complications and costs associated with using ultrasound guidance during abdominal paracentesis procedures.

    PubMed

    Patel, Pankaj A; Ernst, Frank R; Gunnarsson, Candace L

    2012-01-01

    Abdominal paracentesis is commonly performed for diagnostic, therapeutic, and palliative indications, but the use of ultrasound guidance for these procedures is relatively recent, variable, and not well documented. A retrospective database analysis of abdominal paracentesis procedures was performed to determine whether ultrasound guidance was associated with differences in adverse events (AEs) or hospital costs, compared to procedures without ultrasound guidance. The hospital database maintained by Premier was used to identify patients with abdominal paracentesis International Classification of Diseases - 9th Revision - Clinical Modification (ICD-9 code 54.9, Common Procedural Terminology CPT-4 codes 49080, 49081) in 2008. Use of ultrasound guidance was determined via patient billing data. The incidence of selected AEs and patients' hospitalization costs were calculated for two groups: procedures with ultrasound guidance and those without. Univariate and multivariable analyses were performed to evaluate differences between groups. This study identified 1297 abdominal paracentesis procedures, 723 (56%) with ultrasound and 574 (44%) without. The indications for paracentesis were similar between the two groups. The incidence of AEs was lower in ultrasound-guided procedures: all AEs (1.4% vs 4.7%, p = 0.01), post-paracentesis infection (0.41% vs 2.44%, p = 0.01), hematoma (0.0% vs 0.87%, p = 0.01), and seroma (0.14% vs 1.05%, p = 0.03). Analyses adjusted for patient and hospital covariates revealed significant reductions in AEs (OR = 0.349, 95% CI = 0.165, 0.739, p = 0.0059) and hospitalization costs ($8761 ± $5956 vs $9848 ± $6581, p < 0.001) for procedures with ultrasound guidance vs those without. There are several limitations to using claims data for clinical analyses; causality cannot be determined, the possibility of miscoded or missing data, and the inability to control for elements not captured in claims data that may influence clinical outcomes. The use of ultrasound guidance in abdominal paracentesis procedures is associated with fewer AEs and lower hospitalization costs than procedures where ultrasound is not used.

  9. Doppler ultrasound-guided percutaneous nephrolithotomy with two-step tract dilation for management of complex renal stones.

    PubMed

    Xu, Youming; Wu, Zhonghua; Yu, Jianhua; Wang, Shulong; Li, Fang; Chen, Jiushun; Liu, Jin; Chen, Kan

    2012-06-01

    To report our experience and assess the safety and efficacy of Doppler ultrasound-guided percutaneous nephrolithotomy (PCNL) with 2-step tract dilation for complex renal stones. From March 2009 to February 2011, 262 patients underwent PCNL. Eighty-three patients had a complete and 105 had partial staghorn calculus, and 74 had a renal pelvic stone of >2 cm in diameter. Thirty-five patients had renal surgical history. Doppler ultrasound-guided PCNL with 2-step tract dilation were performed. Stones were fragmented and cleared using a combination of ultrasonic and pneumatic lithotripters. All PCNL procedures were successful. Successful access to the collecting system was 100%. Although most of the cases (231/262) were managed satisfactorily by a single tract, a second tract was used in 31 cases. Mean operation time was 56 minutes (range 25-145). The primary stone-free rate of PCNL was 80.9%. There were 39 auxiliary procedures (13 second PCNL and 26 extracorporeal shock wave lithotripsy). One month after treatment, the overall stone-free rate was 92.7%. Five patients (1.9%) received blood transfusion. Eight patients (3.1%) with a postoperative fever of ≥38.5°C were cured by intravenous antibiotics. No other severe complications occurred. The mean postoperative stay was 3.8 days (range 2-12). Doppler ultrasound-guided PCNL with 2-step tract dilation for complex renal stones is safe, effective, and worthy of wider use in clinical practice. Copyright © 2012 Elsevier Inc. All rights reserved.

  10. High-intensity focused ultrasound combined with hysteroscopic resection to treat retained placenta accreta.

    PubMed

    Lee, Jae-Seong; Hong, Gi-Youn; Park, Byung-Joon; Hwang, Hyejin; Kim, Rayon; Kim, Tae-Eung

    2016-09-01

    We present a case of retained placenta accreta treated by high-intensity focused ultrasound (HIFU) ablation followed by hysteroscopic resection. The patient was diagnosed as submucosal myoma based on ultrasonography in local clinic. Pathologic examination of several pieces of tumor mass from the hysteroscopic procedure revealed necrotic chorionic villi with calcification. HIFU was performed using an ultrasound-guided HIFU tumor therapeutic system. The ultrasound machine had been used for real-time monitoring of the HIFU procedure. After HIFU treatment, no additional vaginal bleeding or complications were observed. A hysteroscopic resection was performed to remove ablated placental tissue 7 days later. No abnormal vaginal bleeding or discharge was seen after the procedure. The patient was stable postoperatively. We proposed HIFU and applied additional hysteroscopic resection for a safe and effective method for treating retained placenta accreta to prevent complications from the remaining placental tissue and to improve fertility options.

  11. Point-of-care ultrasound diagnosis and treatment of posterior shoulder dislocation.

    PubMed

    Beck, Sierra; Chilstrom, Mikaela

    2013-02-01

    Acute traumatic posterior shoulder dislocations are rare. The diagnosis is often missed or delayed, as radiologic abnormalities can be subtle. We report a case of a 37-year-old man who presented to the emergency department with severe right shoulder pain and inability to move his arm after a motor vehicle collision. Based on examination, he was initially thought to have an anterior dislocation; however, point-of-care (POC) ultrasound clearly demonstrated a posterior shoulder dislocation. Real-time ultrasound-guided intra-articular local anesthetic injection facilitated closed reduction in the emergency department without procedural sedation, and POC ultrasound confirmed successful reduction at the bedside after the procedure. This case demonstrates that POC ultrasound can be a useful diagnostic tool in the rapid assessment and treatment for patients with suspected posterior shoulder dislocation. Copyright © 2013 Elsevier Inc. All rights reserved.

  12. Feasibility of Retrograde Ureteral Contrast Injection to Guide Ultrasonographic Percutaneous Renal Access in the Nondilated Collecting System.

    PubMed

    Usawachintachit, Manint; Tzou, David T; Mongan, John; Taguchi, Kazumi; Weinstein, Stefanie; Chi, Thomas

    2017-02-01

    Ultrasound-guided percutaneous nephrolithotomy (PCNL) has become increasingly utilized. Patients with nondilated collecting systems represent a challenge: the target calix is often difficult to visualize. Here we report pilot study results for retrograde ultrasound contrast injection to aid in percutaneous renal access during ultrasound-guided PCNL. From April to July 2016, consecutive patients over the age of 18 years with nondilated collecting systems on preoperative imaging who presented for PCNL were enrolled. B-mode ultrasound imaging was compared with contrast-enhanced mode with simultaneous retrograde injection of Optison™ via an ipsilateral ureteral catheter. Five patients (four males and one female) with renal stones underwent PCNL with retrograde ultrasound contrast injection during the study period. Mean body mass index was 28.3 ± 5.6 kg/m 2 and mean stone size was 24.5 ± 12.0 mm. Under B-mode ultrasound, all patients demonstrated nondilated renal collecting systems that appeared as hyperechoic areas, where it was difficult to identify a target calix for puncture. Retrograde contrast injection facilitated delineation of all renal calices initially difficult to visualize under B-mode ultrasound. Renal puncture was then performed effectively in all cases with a mean puncture time of 55.4 ± 44.8 seconds. All PCNL procedures were completed without intraoperative complications and no adverse events related to ultrasound contrast injection occurred. Retrograde ultrasound contrast injection as an aide for renal puncture during PCNL is a feasible technique. By improving visualization of the collecting system, it facilitates needle placement in challenging patients without hydronephrosis. Future larger scale studies comparing its use to standard ultrasound-guided technique will be required to validate this concept.

  13. Technical Note: Error metrics for estimating the accuracy of needle/instrument placement during transperineal magnetic resonance/ultrasound-guided prostate interventions.

    PubMed

    Bonmati, Ester; Hu, Yipeng; Villarini, Barbara; Rodell, Rachael; Martin, Paul; Han, Lianghao; Donaldson, Ian; Ahmed, Hashim U; Moore, Caroline M; Emberton, Mark; Barratt, Dean C

    2018-04-01

    Image-guided systems that fuse magnetic resonance imaging (MRI) with three-dimensional (3D) ultrasound (US) images for performing targeted prostate needle biopsy and minimally invasive treatments for prostate cancer are of increasing clinical interest. To date, a wide range of different accuracy estimation procedures and error metrics have been reported, which makes comparing the performance of different systems difficult. A set of nine measures are presented to assess the accuracy of MRI-US image registration, needle positioning, needle guidance, and overall system error, with the aim of providing a methodology for estimating the accuracy of instrument placement using a MR/US-guided transperineal approach. Using the SmartTarget fusion system, an MRI-US image alignment error was determined to be 2.0 ± 1.0 mm (mean ± SD), and an overall system instrument targeting error of 3.0 ± 1.2 mm. Three needle deployments for each target phantom lesion was found to result in a 100% lesion hit rate and a median predicted cancer core length of 5.2 mm. The application of a comprehensive, unbiased validation assessment for MR/US guided systems can provide useful information on system performance for quality assurance and system comparison. Furthermore, such an analysis can be helpful in identifying relationships between these errors, providing insight into the technical behavior of these systems. © 2018 American Association of Physicists in Medicine.

  14. From the RSNA refresher courses: Image-guided thermal therapy of uterine fibroids.

    PubMed

    Tempany, Clare M

    2007-01-01

    One of the most recent additions to the methods for image-guided therapy is magnetic resonance (MR)-guided focused ultrasound. This method represents a unique closed-loop therapy, with planning, guidance, control, and direct feedback (called MR thermometry), which work together to ensure an effective therapy. The focused ultrasound induces focal tissue destruction by thermocoagulation in a noninvasive manner. MR also enables real-time thermometry to be performed during each and every sonication. These characteristics make MR-guided focused ultrasound an exciting new approach for treating fibroids. Fibroids are diagnosed based on findings from the patient's physical examination supplemented by imaging results. MR imaging is preferred to other imaging modalities because it enables the fibroids and the entire pelvis to be fully examined. After individual fibroids are identified and the target area is defined by the radiologist, the target volume is analyzed in a three-dimensional assessment to ensure the patient's safety. The procedure begins with the delivery of low-power sonication, and the power is gradually increased until the therapeutic dose is reached. After the procedure, postcontrast images are acquired; these should demonstrate tissue necrosis. The results of clinical trials have shown that the treatment is safe, effective, and highly acceptable to patients. RSNA, 2007

  15. A new instrument to assess physician skill at thoracic ultrasound, including pleural effusion markup.

    PubMed

    Salamonsen, Matthew; McGrath, David; Steiler, Geoff; Ware, Robert; Colt, Henri; Fielding, David

    2013-09-01

    To reduce complications and increase success, thoracic ultrasound is recommended to guide all chest drainage procedures. Despite this, no tools currently exist to assess proceduralist training or competence. This study aims to validate an instrument to assess physician skill at performing thoracic ultrasound, including effusion markup, and examine its validity. We developed an 11-domain, 100-point assessment sheet in line with British Thoracic Society guidelines: the Ultrasound-Guided Thoracentesis Skills and Tasks Assessment Test (UGSTAT). The test was used to assess 22 participants (eight novices, seven intermediates, seven advanced) on two occasions while performing thoracic ultrasound on a pleural effusion phantom. Each test was scored by two blinded expert examiners. Validity was examined by assessing the ability of the test to stratify participants according to expected skill level (analysis of variance) and demonstrating test-retest and intertester reproducibility by comparison of repeated scores (mean difference [95% CI] and paired t test) and the intraclass correlation coefficient. Mean scores for the novice, intermediate, and advanced groups were 49.3, 73.0, and 91.5 respectively, which were all significantly different (P < .0001). There were no significant differences between repeated scores. Procedural training on mannequins prior to unsupervised performance on patients is rapidly becoming the standard in medical education. This study has validated the UGSTAT, which can now be used to determine the adequacy of thoracic ultrasound training prior to clinical practice. It is likely that its role could be extended to live patients, providing a way to document ongoing procedural competence.

  16. Endoscopic ultrasound guided drainage of pancreatic fluid collections: Assessment of the procedure, technical details and review of the literature

    PubMed Central

    Puri, Rajesh; Thandassery, Ragesh Babu; Alfadda, Abdulrahman A; Kaabi, Saad Al

    2015-01-01

    Endoscopic ultrasound (EUS) guided drainage of pancreatic fluid collections (PFC) has become increasingly popular and become first line management option in many centers. Use of therapeutic echoendoscopes has greatly increased the applicability of EUS guided transmural drainage. Drainage is indicated in symptomatic PFCs, PFC related infection, bleed, luminal obstruction, fistulization and biliary obstruction. EUS guided transmural drainage of PFCs is preferred in patients with non bulging lesions, portal hypertension, bleeding tendency and in those whom conventional drainage has failed. In the present decade significant progress has been made in minimally invasive endoscopic techniques. There are newer stent designs, access devices and techniques for more efficient drainage of PFCs. In this review, we discuss the EUS guided drainage of PFCs in acute pancreatitis. PMID:25901214

  17. Real-time computed tomography dosimetry during ultrasound-guided brachytherapy for prostate cancer.

    PubMed

    Kaplan, Irving D; Meskell, Paul; Oldenburg, Nicklas E; Saltzman, Brian; Kearney, Gary P; Holupka, Edward J

    2006-01-01

    Ultrasound-guided implantation of permanent radioactive seeds is a treatment option for localized prostate cancer. Several techniques have been described for the optimal placement of the seeds in the prostate during this procedure. Postimplantation dosimetric calculations are performed after the implant. Areas of underdosing can only be corrected with either an external beam boost or by performing a second implant. We demonstrate the feasibility of performing computed tomography (CT)-based postplanning during the ultrasound-guided implant and subsequently correcting for underdosed areas. Ultrasound-guided brachytherapy is performed on a modified CT table with general anesthesia. The postplanning CT scan is performed after the implant, while the patient is still under anesthesia. Additional seeds are implanted into "cold spots," and the resultant dosimetry confirmed with CT. Intraoperative postplanning was successfully performed. Dose-volume histograms demonstrated adequate dose coverage during the initial implant, but on detailed analysis, for some patients, areas of underdosing were observed either at the apex or the peripheral zone. Additional seeds were implanted to bring these areas to prescription dose. Intraoperative postplanning is feasible during ultrasound-guided brachytherapy for prostate cancer. Although the postimplant dose-volume histograms for all patients, before the implantation of additional seeds, were adequate according to the American Brachytherapy Society criteria, specific critical areas can be underdosed. Additional seeds can then be implanted to optimize the dosimetry and reduce the risk of underdosing areas of cancer.

  18. [An easy, safe and affective method for the treatment of intussusception: ultrasound-guided hydrostatic reduction].

    PubMed

    Ülger, Fatma Esra Bahadır; Ülger, Aykut; Karakaya, Ali Erdal; Tüten, Fatih; Katı, Ömer; Çolak, Mustafa

    2014-03-01

    Intussusception is one of the important causes of intestinal obstruction in children. Hydrostatic reduction under ultrasound guidance is a popular treatment method for intussusception. In the present study, we aimed to explain the demographic characteristics of and treatment approaches in patients diagnosed with intussusception by ultrasound. Forty-one patients diagnosed with intussusception by ultrasound between August 2011 and May 2013 were retrospectively analyzed. Twenty-four of these patients who had no contraindications had been treated with ultrasound-guided hydrostatic reduction. Twenty-four of the patients were male and 17 were female, a 1.4/1 male-to-female ratio. The majority of the patients were between the ages of 6-24 months and 2-5 years. The mean age was 31.12±26.32 months (range 3-125). Patients were more frequently diagnosed in April and May. Seventeen patients who had clinical contraindications enrolled directly for surgery. In 20 of the 24 patients who underwent ultrasound-guided hydrostatic reduction, reduction was achieved. Three experienced recurrence. In two of these patients, successful reduction was achieved with the second attempt. The remaining patient was enrolled for surgery. Hydrostatic reduction was performed 26 times on these 24 patients, and in 22, success was achieved (84.6%). No procedure-related complications occurred in the patients. Ultrasound-guided hydrostatic reduction, with its high success rates and lack of radiation risk, should be the first choice therapeutic approach for children diagnosed with intussusception.

  19. Workflow and intervention times of MR-guided focused ultrasound - Predicting the impact of new techniques.

    PubMed

    Loeve, Arjo J; Al-Issawi, Jumana; Fernandez-Gutiérrez, Fabiola; Langø, Thomas; Strehlow, Jan; Haase, Sabrina; Matzko, Matthias; Napoli, Alessandro; Melzer, Andreas; Dankelman, Jenny

    2016-04-01

    Magnetic resonance guided focused ultrasound surgery (MRgFUS) has become an attractive, non-invasive treatment for benign and malignant tumours, and offers specific benefits for poorly accessible locations in the liver. However, the presence of the ribcage and the occurrence of liver motion due to respiration limit the applicability MRgFUS. Several techniques are being developed to address these issues or to decrease treatment times in other ways. However, the potential benefit of such improvements has not been quantified. In this research, the detailed workflow of current MRgFUS procedures was determined qualitatively and quantitatively by using observation studies on uterine MRgFUS interventions, and the bottlenecks in MRgFUS were identified. A validated simulation model based on discrete events simulation was developed to quantitatively predict the effect of new technological developments on the intervention duration of MRgFUS on the liver. During the observation studies, the duration and occurrence frequencies of all actions and decisions in the MRgFUS workflow were registered, as were the occurrence frequencies of motion detections and intervention halts. The observation results show that current MRgFUS uterine interventions take on average 213min. Organ motion was detected on average 2.9 times per intervention, of which on average 1.0 actually caused a need for rework. Nevertheless, these motion occurrences and the actions required to continue after their detection consumed on average 11% and up to 29% of the total intervention duration. The simulation results suggest that, depending on the motion occurrence frequency, the addition of new technology to automate currently manual MRgFUS tasks and motion compensation could potentially reduce the intervention durations by 98.4% (from 256h 5min to 4h 4min) in the case of 90% motion occurrence, and with 24% (from 5h 19min to 4h 2min) in the case of no motion. In conclusion, new tools were developed to predict how intervention durations will be affected by future workflow changes and by the introduction of new technology. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. In-plane ultrasonic needle tracking using a fiber-optic hydrophone

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xia, Wenfeng, E-mail: wenfeng.xia@ucl.ac.uk; Desjardins, Adrien E.; Mari, Jean Martial

    Purpose: Accurate and efficient guidance of needles to procedural targets is critically important during percutaneous interventional procedures. Ultrasound imaging is widely used for real-time image guidance in a variety of clinical contexts, but with this modality, uncertainties about the location of the needle tip within the image plane lead to significant complications. Whilst several methods have been proposed to improve the visibility of the needle, achieving accuracy and compatibility with current clinical practice is an ongoing challenge. In this paper, the authors present a method for directly visualizing the needle tip using an integrated fiber-optic ultrasound receiver in conjunction withmore » the imaging probe used to acquire B-mode ultrasound images. Methods: Needle visualization and ultrasound imaging were performed with a clinical ultrasound imaging system. A miniature fiber-optic ultrasound hydrophone was integrated into a 20 gauge injection needle tip to receive transmissions from individual transducer elements of the ultrasound imaging probe. The received signals were reconstructed to create an image of the needle tip. Ultrasound B-mode imaging was interleaved with needle tip imaging. A first set of measurements was acquired in water and tissue ex vivo with a wide range of insertion angles (15°–68°) to study the accuracy and sensitivity of the tracking method. A second set was acquired in an in vivo swine model, with needle insertions to the brachial plexus. A third set was acquired in an in vivo ovine model for fetal interventions, with insertions to different locations within the uterine cavity. Two linear ultrasound imaging probes were used: a 14–5 MHz probe for the first and second sets, and a 9–4 MHz probe for the third. Results: During insertions in tissue ex vivo and in vivo, the imaged needle tip had submillimeter axial and lateral dimensions. The signal-to-noise (SNR) of the needle tip was found to depend on the insertion angle. With the needle tip in water, the SNR of the needle tip varied with insertion angle, attaining values of 284 at 27° and 501 at 68°. In swine tissue ex vivo, the SNR decreased from 80 at 15° to 16 at 61°. In swine tissue in vivo, the SNR varied with depth, from 200 at 17.5 mm to 48 at 26 mm, with a constant insertion angle of 40°. In ovine tissue in vivo, within the uterine cavity, the SNR varied from 46.4 at 25 mm depth to 18.4 at 32 mm depth, with insertion angles in the range of 26°–65°. Conclusions: A fiber-optic ultrasound receiver integrated into the needle cannula in combination with single-element transmissions from the imaging probe allows for direct visualization of the needle tip within the ultrasound imaging plane. Visualization of the needle tip was achieved at depths and insertion angles that are encountered during nerve blocks and fetal interventions. The method presented in this paper has strong potential to improve the safety and efficiency of ultrasound-guided needle insertions.« less

  1. Sterile working in ultrasonography: the use of dedicated ultrasound covers and sterile ultrasound gel.

    PubMed

    Marhofer, Peter; Fritsch, Gerhard

    2015-01-01

    Ultrasound is currently an important tool for diagnostic and interventional procedures. Ultrasound imaging provides significant advantages as compared to other imaging methods. The widespread use of ultrasound also carries the risk of drawbacks such as cross-infections. A large body of literature reports this possibly life-threatening side effect and specific patient populations are particularly at risk (e.g., neonates). Various methods of ultrasound probe disinfection are described; however, none of the mechanical or chemical probe disinfection procedures is optimal and, in particular, disinfection with high concentration of alcohol might be associated with ultrasound probe damage. The preparation of ultrasound probes with dedicated probe covers is a useful alternative for sterile working conditions. One ultrasound probe cover discussed in this paper is directly glued on to the ultrasound probe without the use of ultrasound coupling gel. By the use of sterile ultrasound coupling gel at the outer surface, additional effects on aseptic working conditions can be obtained.

  2. Changing attitudes toward needle biopsies of breast cancer in Shanghai: experience and current status over the past 8 years

    PubMed Central

    Hao, Shuang; Liu, Zhe-Bin; Ling, Hong; Chen, Jia-Jian; Shen, Ju-Ping; Yang, Wen-Tao; Shao, Zhi-Min

    2015-01-01

    Diagnostic patterns in breast cancer have greatly changed over the past few decades, and core needle biopsy (CNB) has become a reliable procedure for detecting breast cancer without invasive surgery. To estimate the changing diagnostic patterns of breast cancer in urban Shanghai, 11,947 women with breast lesions detected by preoperative needle biopsy between January 1995 and December 2012 were selected from the Shanghai Cancer Data base, which integrates information from approximately 50% of breast cancer patients in Shanghai. The CNB procedure uses an automated prone unit, biopsy gun, and 14-gauge needles under freehand or ultrasound guidance and was performed by experienced radiologists and surgeons specializing in needle biopsies. Diagnosis and classification for each patient were independently evaluated by pathologists. Over the indicated 8-year period, biopsy type consisted of 11,947 ultrasound-guided core needle biopsies (UCNBs), 2,015 ultrasound-guided vacuum-assisted biopsies (UVABs), and 654 stereotactic X-ray-guided vacuum-assisted biopsies (XVABs). For all the 11,947 women included in this study, image-guided needle biopsy was the initial diagnostic procedure. Approximately 81.0% of biopsied samples were histopathologically determined to be malignant lesions, 5.5% were determined to be high-risk lesions, and 13.5% were determined to be benign lesions. The number of patients choosing UCNB increased at the greatest rate, and UCNB has become a standard procedure for histodiagnosis because it is inexpensive, convenient, and accurate. The overall false-negative rate of CNB was 1.7%, and the specific false-negative rates for UCNB, UVAB, and XVAB, were 1.7%, 0%, and 0%, respectively. This study suggests that the use of preoperative needle biopsy as the initial breast cancer diagnostic procedure is acceptable in urban Shanghai. Preoperative needle biopsy is now a standard procedure in the Shanghai Cancer Center because it may reduce the number of surgeries needed to treat breast cancer. PMID:26491359

  3. Perspectives in ultrasound-guided musculoskeletal interventions

    PubMed Central

    Daftary, Aditya Ravindra; Karnik, Alpana Sudhir

    2015-01-01

    Ultrasonography (USG) is a safe, easily available, and cost-effective modality, which has the additional advantage of being real time for imaging and image-guided interventions of the musculoskeletal system. Musculoskeletal interventions are gaining popularity in sports and rehabilitation for rapid healing of muscle and tendon injuries in professional athletes, healing of chronic tendinopathies, aspiration of joint effusions, periarticular bursae and ganglia, and perineural injections in acute and chronic pain syndromes. This article aims to provide an overview of the spectrum of musculoskeletal interventions that can be done under USG guidance both for diagnostic and therapeutic purposes. PMID:26288519

  4. Emergency percutaneous treatment in surgical bile duct injury.

    PubMed

    Carrafiello, Gianpaolo; Laganà, Domenico; Dizonno, Massimiliano; Ianniello, Andrea; Cotta, Elisa; Dionigi, Gianlorenzo; Dionigi, Renzo; Fugazzola, Carlo

    2008-09-01

    The aim of this study is to evaluate the efficacy of emergency percutaneous treatment in patients with surgical bile duct injury (SBDI). From May 2004 to May 2007, 11 patients (five men, six women; age range 26-80 years; mean age 58 years) with a critical clinical picture (severe jaundice, bile peritonitis, septic state) due to SBDI secondary to surgical or laparoscopic procedures were treated by percutaneous procedures. We performed four ultrasound-guided percutaneous drainages, four external-internal biliary drainages, one bilioplasty, and two plastic biliary stenting after 2 weeks of external-internal biliary drainage placement. All procedures had 100% technical success with no complications. The clinical emergencies resolved in 3-4 days in 100% of cases. All patients had a benign clinical course, and reoperation was avoided in 100% of cases. Interventional radiological procedures are effective in the emergency management of SBDI since they are minimally invasive and have a high success rate and a low incidence of complications compared to the more complex and dangerous surgical or laparoscopic options.

  5. MO-DE-202-00: Image-Guided Interventions: Advances in Intraoperative Imaging, Guidance, and An Emerging Role for Medical Physics in Surgery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    At least three major trends in surgical intervention have emerged over the last decade: a move toward more minimally invasive (or non-invasive) approach to the surgical target; the development of high-precision treatment delivery techniques; and the increasing role of multi-modality intraoperative imaging in support of such procedures. This symposium includes invited presentations on recent advances in each of these areas and the emerging role for medical physics research in the development and translation of high-precision interventional techniques. The four speakers are: Keyvan Farahani, “Image-guided focused ultrasound surgery and therapy” Jeffrey H. Siewerdsen, “Advances in image registration and reconstruction for image-guidedmore » neurosurgery” Tina Kapur, “Image-guided surgery and interventions in the advanced multimodality image-guided operating (AMIGO) suite” Raj Shekhar, “Multimodality image-guided interventions: Multimodality for the rest of us” Learning Objectives: Understand the principles and applications of HIFU in surgical ablation. Learn about recent advances in 3D–2D and 3D deformable image registration in support of surgical safety and precision. Learn about recent advances in model-based 3D image reconstruction in application to intraoperative 3D imaging. Understand the multi-modality imaging technologies and clinical applications investigated in the AMIGO suite. Understand the emerging need and techniques to implement multi-modality image guidance in surgical applications such as neurosurgery, orthopaedic surgery, vascular surgery, and interventional radiology. Research supported by the NIH and Siemens Healthcare.; J. Siewerdsen; Grant Support - National Institutes of Health; Grant Support - Siemens Healthcare; Grant Support - Carestream Health; Advisory Board - Carestream Health; Licensing Agreement - Carestream Health; Licensing Agreement - Elekta Oncology.; T. Kapur, P41EB015898; R. Shekhar, Funding: R42CA137886 and R41CA192504 Disclosure and CoI: IGI Technologies, small-business partner on the grants.« less

  6. MO-DE-202-04: Multimodality Image-Guided Surgery and Intervention: For the Rest of Us

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shekhar, R.

    At least three major trends in surgical intervention have emerged over the last decade: a move toward more minimally invasive (or non-invasive) approach to the surgical target; the development of high-precision treatment delivery techniques; and the increasing role of multi-modality intraoperative imaging in support of such procedures. This symposium includes invited presentations on recent advances in each of these areas and the emerging role for medical physics research in the development and translation of high-precision interventional techniques. The four speakers are: Keyvan Farahani, “Image-guided focused ultrasound surgery and therapy” Jeffrey H. Siewerdsen, “Advances in image registration and reconstruction for image-guidedmore » neurosurgery” Tina Kapur, “Image-guided surgery and interventions in the advanced multimodality image-guided operating (AMIGO) suite” Raj Shekhar, “Multimodality image-guided interventions: Multimodality for the rest of us” Learning Objectives: Understand the principles and applications of HIFU in surgical ablation. Learn about recent advances in 3D–2D and 3D deformable image registration in support of surgical safety and precision. Learn about recent advances in model-based 3D image reconstruction in application to intraoperative 3D imaging. Understand the multi-modality imaging technologies and clinical applications investigated in the AMIGO suite. Understand the emerging need and techniques to implement multi-modality image guidance in surgical applications such as neurosurgery, orthopaedic surgery, vascular surgery, and interventional radiology. Research supported by the NIH and Siemens Healthcare.; J. Siewerdsen; Grant Support - National Institutes of Health; Grant Support - Siemens Healthcare; Grant Support - Carestream Health; Advisory Board - Carestream Health; Licensing Agreement - Carestream Health; Licensing Agreement - Elekta Oncology.; T. Kapur, P41EB015898; R. Shekhar, Funding: R42CA137886 and R41CA192504 Disclosure and CoI: IGI Technologies, small-business partner on the grants.« less

  7. Technical Aspects of Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration: CHEST Guideline and Expert Panel Report.

    PubMed

    Wahidi, Momen M; Herth, Felix; Yasufuku, Kazuhiro; Shepherd, Ray Wesley; Yarmus, Lonny; Chawla, Mohit; Lamb, Carla; Casey, Kenneth R; Patel, Sheena; Silvestri, Gerard A; Feller-Kopman, David J

    2016-03-01

    Endobronchial ultrasound (EBUS) was introduced in the last decade, enabling real-time guidance of transbronchial needle aspiration (TBNA) of mediastinal and hilar structures and parabronchial lung masses. The many publications produced about EBUS-TBNA have led to a better understanding of the performance characteristics of this procedure. The goal of this document was to examine the current literature on the technical aspects of EBUS-TBNA as they relate to patient, technology, and proceduralist factors to provide evidence-based and expert guidance to clinicians. Rigorous methodology has been applied to provide a trustworthy evidence-based guideline and expert panel report. A group of approved panelists developed key clinical questions by using the PICO (population, intervention, comparator, and outcome) format that addressed specific topics on the technical aspects of EBUS-TBNA. MEDLINE (via PubMed) and the Cochrane Library were systematically searched for relevant literature, which was supplemented by manual searches. References were screened for inclusion, and well-recognized document evaluation tools were used to assess the quality of included studies, to extract meaningful data, and to grade the level of evidence to support each recommendation or suggestion. Our systematic review and critical analysis of the literature on 15 PICO questions related to the technical aspects of EBUS-TBNA resulted in 12 statements: 7 evidence-based graded recommendations and 5 ungraded consensus-based statements. Three questions did not have sufficient evidence to generate a statement. Evidence on the technical aspects of EBUS-TBNA varies in strength but is satisfactory in certain areas to guide clinicians on the best conditions to perform EBUS-guided tissue sampling. Additional research is needed to enhance our knowledge regarding the optimal performance of this effective procedure. Copyright © 2016 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.

  8. Pain reduction and improvement of function following ultrasound-guided intra-articular injections of triamcinolone hexacetonide and hyaluronic acid in hip osteoarthritis.

    PubMed

    Araújo, J P; Silva, L; Andrade, R; Paços, M; Moreira, H; Migueis, N; Pereira, R; Sarmento, A; Pereira, H; Loureiro, N; Espregueira-Mendes, J

    2016-01-01

    The scientific literature has shown positive results regarding intra-articular injections of hyaluronic acid in osteoarthritic joints. When injecting in the hip joint, the guidance of ultrasound can provide higher injection accuracy and repeatability. However, due to the methodological limitations in the current available literature, its recommendation in the current practice is still controversial. This study shows that ultrasound-guided intra-articular injections of triamcinolone hexacetonide and hyaluronic acid can improve pain, function and quality of life in patients with symptomatic and radiographic hip osteoarthritis. In addition, the administration of triamcinolone hexacetonide and hyaluronic acid to the hip joint in these patients can delay the need for interventional surgery.

  9. Ultrasound-Guided Percutaneous Catheter Drainage of Large Breast Abscesses in Lactating Women: How to Preserve Breastfeeding Safely.

    PubMed

    Falco, Giuseppe; Foroni, Monica; Castagnetti, Fabio; Marano, Luigi; Bordoni, Daniele; Rocco, Nicola; Marchesi, Vanessa; Iotti, Valentina; Vacondio, Rita; Ferrari, Guglielmo

    2016-12-01

    Management of breast abscess in lactating women remains controversial. During pregnancy, women may develop different kinds of benign breast lesions that could require a surgical incision performed under general anesthesia with consequent breastfeeding interruption. The purpose of this study was to prospectively evaluate the management of large breast abscesses with ultrasound-assisted drainage aiming at breastfeeding preservation. 34 lactating women with a diagnosis of unilateral breast abscess have been treated with an ultrasound (US)-assisted drainage of the abscess. A pigtail catheter was inserted into the fluid collection using the Seldinger technique under US guide and connected to a three stop way to allow drainage and irrigation of the cavity until its resolution. All procedures have been found safe and well tolerated. No recurrence was observed and breastfeeding was never interrupted. The described technique allows to avoid surgery and to preserve breastfeeding in well-selected patients with a safe, well-tolerated and cost-effective procedure.

  10. American Medical Society for Sports Medicine recommended sports ultrasound curriculum for sports medicine fellowships.

    PubMed

    Finnoff, Jonathan T; Berkoff, David; Brennan, Fred; DiFiori, John; Hall, Mederic M; Harmon, Kimberly; Lavallee, Mark; Martin, Sean; Smith, Jay; Stovak, Mark

    2015-02-01

    The American Medical Society for Sports Medicine (AMSSM) developed a musculoskeletal ultrasound curriculum for sports medicine fellowships in 2010. As the use of diagnostic and interventional ultrasound in sports medicine has evolved, it became clear that the curriculum needed to be updated. Furthermore, the name 'musculoskeletal ultrasound' was changed to 'sports ultrasound' (SPORTS US) to reflect the broad range of diagnostic and interventional applications of ultrasound in sports medicine. This document was created to outline the core competencies of SPORTS US and to provide sports medicine fellowship directors and others interested in SPORTS US education with a guide to create a SPORTS US curriculum. By completing this SPORTS US curriculum, sports medicine fellows and physicians can attain proficiency in the core competencies of SPORTS US required for the practice of sports medicine. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  11. Current situation regarding central venous port implantation procedures and complications: a questionnaire-based survey of 11,693 implantations in Japan.

    PubMed

    Shiono, Masatoshi; Takahashi, Shin; Takahashi, Masanobu; Yamaguchi, Takuhiro; Ishioka, Chikashi

    2016-12-01

    We conducted a nationwide questionnaire-based survey to understand the current situation regarding central venous port implantation in order to identify the ideal procedure. Questionnaire sheets concerning the number of implantation procedures and the incidence of complications for all procedures completed in 2012 were sent to 397 nationwide designated cancer care hospitals in Japan in June 2013. Venipuncture sites were categorized as chest, neck, upper arm, forearm, and others. Methods were categorized as landmark, cut-down, ultrasound-mark, real-time ultrasound guided, venography, and other groups. We received 374 responses (11,693 procedures) from 153 centers (38.5 %). The overall complication rates were 7.4 % for the chest (598/8,097 cases); 6.8 % for the neck (157/2325); 5.2 % for the upper arm (54/1,033); 7.3 % for the forearm (9/124); and 6.1 % for the other groups (7/114). Compared to the chest group, only the upper arm group showed a significantly lower incidence of complications (P = 0.010), and multivariate logistic regression (odds ratio 0.69; 95 % confidence interval 0.51-0.91; P = 0.008) also showed similar findings. Real-time ultrasound-guided puncture was most commonly used in the upper arm group (83.8 %), followed by the neck (69.8 %), forearm (53.2 %), chest (41.8 %), and other groups (34.2 %). Upper arm venipuncture with ultrasound guidance seems the most promising technique to prevent complications of central venous port implantation.

  12. Efficacy and safety of point-of-care ultrasound-guided intra-articular corticosteroid joint injections in patients with haemophilic arthropathy.

    PubMed

    Martin, E J; Cooke, E J; Ceponis, A; Barnes, R F W; Moran, C M; Holle, S; Hughes, T H; Moore, R E; von Drygalski, A

    2017-01-01

    Intra-articular corticosteroid injections are standard of care for managing joint pain secondary to osteoarthritis or rheumatoid arthritis but are rarely used in haemophilic arthropathy. We have introduced and evaluated the efficacy and safety of ultrasound-guided corticosteroid injections for pain relief in patients with haemophilic arthropathy. Ultrasound-guided intra-articular injections performed on haemophilia patients at UCSD between March 2012 and January 2016 were analysed. Needle placement and injection (40 mg triamcinolone; 3-5 mL lidocaine) were performed with musculoskeletal ultrasound and Power Doppler. Analysis included patient demographics, joint-specific parameters such as tissue hypervascularity and effusions, pain relief, and procedure-associated complications. Forty-five injections (14 ankles, 13 elbows, 18 knees) were administered in 25 patients. Advanced arthropathy with hypervascularity and/or effusions was present in 91% and 61% of joints, respectively. Ninety-one per cent of injections resulted in pain relief which was significant in 84% (>30% reduction). Median pain score was reduced from 7 of 10 to 1 of 10 (P < 0.001), usually within 24 h. Median duration of pain relief was 8 weeks (range 1-16 weeks). Haemophilia B patients experienced longer periods of relief, and high Pettersson scores were associated with shorter duration of relief. There were no procedure-associated complications. Repeat ultrasound of eight joints within 4 weeks of injection demonstrated nearly complete resolution of hypervascularity. Point-of-care ultrasound enabled intra-articular corticosteroid injections that provided highly effective, safe, and relatively long-lasting pain relief in haemophilic arthropathy. This approach should be used to improve pain management in haemophilic arthropathy. © 2016 John Wiley & Sons Ltd.

  13. Glenohumeral joint injection: a comparative study of ultrasound and fluoroscopically guided techniques before MR arthrography.

    PubMed

    Rutten, Matthieu J C M; Collins, James M P; Maresch, Bas J; Smeets, Jacques H J M; Janssen, Caroline M M; Kiemeney, Lambertus A L M; Jager, Gerrit J

    2009-03-01

    To assess the variability in accuracy of contrast media introduction, leakage, required time and patient discomfort in four different centres, each using a different image-guided glenohumeral injection technique. Each centre included 25 consecutive patients. The ultrasound-guided anterior (USa) and posterior approach (USp), fluoroscopic-guided anterior (FLa) and posterior (FLp) approach were used. Number of injection attempts, effect of contrast leakage on diagnostic quality, and total room, radiologist and procedure times were measured. Pain was documented with a visual analogue scale (VAS) pain score. Access to the joint was achieved in all patients. A successful first attempt significantly occurred more often with US (94%) than with fluoroscopic guidance (72%). Leakage of contrast medium did not cause interpretative difficulties. With US guidance mean room, procedure and radiologist times were significantly shorter (p < 0.001). The USa approach was rated with the lowest pre- and post-injection VAS scores. The four image-guided injection techniques are successful in injection of contrast material into the glenohumeral joint. US-guided injections and especially the anterior approach are significantly less time consuming, more successful on the first attempt, cause less patient discomfort and obviate the need for radiation and iodine contrast.

  14. The Acoustic Lens Design and in Vivo Use of a Multifunctional Catheter Combining Intracardiac Ultrasound Imaging and Electrophysiology Sensing

    PubMed Central

    Stephens, Douglas N.; Cannata, Jonathan; Liu, Ruibin; Zhao, Jian Zhong; Shung, K. Kirk; Nguyen, Hien; Chia, Raymond; Dentinger, Aaron; Wildes, Douglas; Thomenius, Kai E.; Mahajan, Aman; Shivkumar, Kalyanam; Kim, Kang; O’Donnell, Matthew; Sahn, David

    2009-01-01

    A multifunctional 9F intracardiac imaging and electrophysiology mapping catheter was developed and tested to help guide diagnostic and therapeutic intracardiac electrophysiology (EP) procedures. The catheter tip includes a 7.25-MHz, 64-element, side-looking phased array for high resolution sector scanning. Multiple electrophysiology mapping sensors were mounted as ring electrodes near the array for electrocardiographic synchronization of ultrasound images. The catheter array elevation beam performance in particular was investigated. An acoustic lens for the distal tip array designed with a round cross section can produce an acceptable elevation beam shape; however, the velocity of sound in the lens material should be approximately 155 m/s slower than in tissue for the best beam shape and wide bandwidth performance. To help establish the catheter’s unique ability for integration with electrophysiology interventional procedures, it was used in vivo in a porcine animal model, and demonstrated both useful intracardiac echocardiographic visualization and simultaneous 3-D positional information using integrated electroanatomical mapping techniques. The catheter also performed well in high frame rate imaging, color flow imaging, and strain rate imaging of atrial and ventricular structures. PMID:18407850

  15. Ultrasound guided electrochemotherapy for the treatment of a clear cell thymoma in a cat

    PubMed Central

    Spugnini, Enrico Pierluigi; Menicagli, Francesco; Pettorali, Michela; Baldi, Alfonso

    2017-01-01

    A twelve-year-old male castrated domestic shorthair cat was presented for rapidly progressing respiratory distress. The cat was depressed, tachypneic and moderately responsive. Ultrasonography showed a mediastinal mass associated with a significant pleural effusion that needed tapping every five to seven days. Ultrasound guided biopsy yielded a diagnosis of clear cell thymoma upon histopathology. After complete staging procedures, the owner elected to treat the cat with electrochemotherapy (ECT) using systemic bleomycin. Two sessions of ultrasound guided ECT were performed at two week intervals with trains of biphasic electric pulses applied using needle electrodes until complete coverage of the area was achieved. The treatment was well tolerated and resulted in partial remission (PR). Additional sessions were performed on a monthly basis. The cat is still in PR after fourteen months. ECT resulted in improved local control and should be considered among the available adjuvant treatments in pets carrying visceral tumors. PMID:28331834

  16. Rotational atherectomy ablation for an unexpandable stent under the guide of IVUS

    PubMed Central

    Si, Daoyuan; Liu, Guohui; Tong, Yaliang; He, Yuquan

    2018-01-01

    Abstract Rationale: Inadequate stent expansion due to rigid calcified may result in restenosis lesions, but the available options are limited. Patient concerns: We report a case via the trans-radial approach of the severely underexpanded freshly deployed stent due to heavily calcified plaques Diagnoses: Coronary angiography revealed that there was no adequate expansion of the freshly deployed stent. Interventions: Under the guide of intravascular ultrasound (IVUS), rotational atherectomy (RA) successfully ablated the stent layers and the protruding calcified plaque. Followed by balloon angioplasty, the ablated segment was scaffolded with another stent, well expanded and documented by IVUS. Outcomes: The patient was uneventful during the procedure and remained angina free at the point of one year of clinical follow-up. Lessons: This case indicated that RA via the trans-radial approach could be a useful remedy in the situation of under-expansion of implanted stents, and the debulking should be performed under IVUS-guidance. PMID:29443790

  17. Passive Markers for Tracking Surgical Instruments in Real-Time 3-D Ultrasound Imaging

    PubMed Central

    Stoll, Jeffrey; Ren, Hongliang; Dupont, Pierre E.

    2013-01-01

    A family of passive echogenic markers is presented by which the position and orientation of a surgical instrument can be determined in a 3-D ultrasound volume, using simple image processing. Markers are attached near the distal end of the instrument so that they appear in the ultrasound volume along with the instrument tip. They are detected and measured within the ultrasound image, thus requiring no external tracking device. This approach facilitates imaging instruments and tissue simultaneously in ultrasound-guided interventions. Marker-based estimates of instrument pose can be used in augmented reality displays or for image-based servoing. Design principles for marker shapes are presented that ensure imaging system and measurement uniqueness constraints are met. An error analysis is included that can be used to guide marker design and which also establishes a lower bound on measurement uncertainty. Finally, examples of marker measurement and tracking algorithms are presented along with experimental validation of the concepts. PMID:22042148

  18. Preintervention lesion remodelling affects operative mechanisms of balloon optimised directional coronary atherectomy procedures: a volumetric study with three dimensional intravascular ultrasound

    PubMed Central

    von Birgelen, C; Mintz, G; de Vrey, E A; Serruys, P; Kimura, T; Nobuyoshi, M; Popma, J; Leon, M; Erbel, R; de Feyter, P J

    2000-01-01

    AIMS—To classify atherosclerotic coronary lesions on the basis of adequate or inadequate compensatory vascular enlargement, and to examine changes in lumen, plaque, and vessel volumes during balloon optimised directional coronary atherectomy procedures in relation to the state of adaptive remodelling before the intervention.
DESIGN—29 lesion segments in 29 patients were examined with intravascular ultrasound before and after successful balloon optimised directional coronary atherectomy procedures, and a validated volumetric intravascular ultrasound analysis was performed off-line to assess the atherosclerotic lesion remodelling and changes in plaque and vessel volumes that occurred during the intervention. Based on the intravascular ultrasound data, lesions were classified according to whether there was inadequate (group I) or adequate (group II) compensatory enlargement.
RESULTS—There was no significant difference in patient and lesion characteristics between groups I and II (n = 10 and 19), including lesion length and details of the intervention. Quantitative coronary angiographic data were similar for both groups. However, plaque and vessel volumes were significantly smaller in group I than in II. In group I, 9 (4)% (mean (SD)) of the plaque volume was ablated, while in group II 16 (11)% was ablated (p = 0.01). This difference was reflected in a lower lumen volume gain in group I than in group II (46 (18) mm3 v 80 (49) mm3 (p < 0.02)).
CONCLUSIONS—Preintervention lesion remodelling has an impact on the operative mechanisms of balloon optimised directional coronary atherectomy procedures. Plaque ablation was found to be particularly low in lesions with inadequate compensatory vascular enlargement.


Keywords: intravascular ultrasound; ultrasonics; remodelling; coronary artery disease; atherectomy PMID:10648496

  19. Ultrasound-guided injection of botulinum toxin A in the treatment of iliopsoas spasticity

    PubMed Central

    Sconfienza, L.M.; Perrone, N.; Lacelli, F.; Lentino, C.; Serafini, G.

    2008-01-01

    Purpose Intramuscular injection of botulinum toxin A (BTX-A) is a common treatment for iliopsoas muscle spasticity, but it is not easy to position the needle in this muscle without guidance. In this paper we describe an ultrasound-guided technique for the intramuscular injection of BTX-A to treat spasticity of the iliopsoas muscle. Its effectiveness was assessed in 10 patients. Method and materials The ultrasound-guided technique for BTX-A injection was used on 10 patients. The needle was inserted into the muscle belly at an angle of 45° along the longitudinal axis of the muscle when allowed by patient's condition. Results In all cases, the iliopsoas muscle was easily identified and both the iliac and psoas components were assessed. Introduction of the needle and drug injection were entirely carried out under ultrasonographic guidance. The procedure was successful in all patients, even in those with a high-grade spasticity, and general anesthesia was not required. Conclusions This ultrasound-guided technique allows accurate guidance for the injection of BTX-A, and it can be considered as an alternate supportive therapy in patients with spasticity and dystonia. PMID:23396653

  20. Comparison of a novel real-time SonixGPS needle-tracking ultrasound technique with traditional ultrasound for vascular access in a phantom gel model.

    PubMed

    Kopac, Daniel S; Chen, Jerry; Tang, Raymond; Sawka, Andrew; Vaghadia, Himat

    2013-09-01

    Ultrasound-guided percutaneous vascular access for endovascular procedures is well established in surgical practice. Despite this, rates of complications from venous and arterial access procedures remain a significant cause of morbidity. We hypothesized that the use of a new technique of vascular access using an ultrasound with a novel needle-guidance positioning system (GPS) would lead to improved success rates of vascular puncture for both in-plane and out-of-plane techniques compared with traditional ultrasound. A prospective, randomized crossover study of medical students from all years of medical school was conducted using a phantom gel model. Each medical student performed three ultrasound-guided punctures with each of the four modalities (in-plane no GPS, in-plane with GPS, out-of-plane no GPS, out-of-plane with GPS) for a total of 12 attempts. The success or failure was judged by the ability to aspirate a simulated blood solution from the model. The time to successful puncture was also recorded. A poststudy validated NASA Task Load Index workload questionnaire was conducted to assess the student's perceptions of the two different techniques. A total of 30 students completed the study. There was no significant difference seen in the mean times of vascular access for each of the modalities. Higher success rates for vascular access using the GPS for both the in-plane (94% vs 91%) and the out-of-plane (86% vs 70%) views were observed; however, this was not statistically significant. The students perceived the mental demand (median 12.0 vs 14.00; P = .035) and effort to be lower (mean 11.25 vs 14.00; P = .044) as well as the performance to be higher (mean 15.50 vs 14.00; P = .041) for the GPS vs the traditional ultrasound-guided technique. Students also perceived their ability to access vessels increased with the aid of the GPS (7.00 vs 6.50; P = .007). The majority of students expressed a preference for GPS (26/30, 87%) as opposed to the traditional counterpart. Use of the novel SonixGPS needle-tracking ultrasound system (UltraSonix, Richmond, BC, Canada) was not associated with a higher success rate of vascular puncture compared with the traditional ultrasound-guided technique. Assessment of mental task load significantly favored the use of the ultrasound GPS over the traditional ultrasound technique. Copyright © 2013 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

  1. PubMed Central

    Papathemelis, Thomas; Heim, Stefanie; Lux, Michael P.; Erhardt, Ines; Scharl, Anton; Scharl, Sophia

    2017-01-01

    Introduction We studied the extent to which an ultrasound-guided vacuum-assisted biopsy device (“hand-held Mammotome”) could be used not only as a valuable tool for investigation of suspicious breast lesions, but also therapeutically for the complete removal of breast fibroadenomas. Materials and Methods 132 aspiration biopsies showing fibroadenoma on histology were collected retrospectively. We ascertained whether there were residual findings on breast ultrasound at a median follow-up of approx. 9 months following biopsy. A questionnaire was used to determine the complication rate, patient satisfaction and acceptance of the procedure. Results In this study complete fibroadenomectomy was achieved at aspiration biopsy in 76 % of cases (n = 132). Compared to fibroadenomas larger than 2.51 cm3 (59 %), those smaller than 2.5 cm3 were completely removed more often (87.6 %; p < 0.05). The procedure is associated with very little pain during and after biopsy and minimal haematoma development, both factors supporting a high rate of acceptance among patients. Conclusion Ultrasound-guided vacuum-assisted biopsy is safe and associated with very few complications. Its additional therapeutic potential is dependant on the size of the benign lesion as measured at initial ultrasound. PMID:28331240

  2. Use of Lymph Node Ultrasound Prior to Sentinel Lymph Node Biopsy in 384 Patients with Melanoma: A Cost-Effectiveness Analysis.

    PubMed

    Olmedo, D; Brotons-Seguí, M; Del Toro, C; González, M; Requena, C; Traves, V; Pla, A; Bolumar, I; Moreno-Ramírez, D; Nagore, E

    2017-12-01

    Locoregional lymph node ultrasound is not typically included in guidelines as part of the staging process prior to sentinel lymph node biopsy (SLNB). The objective of the present study was to make a clinical and economic analysis of lymph node ultrasound prior to SLNB. We performed a retrospective study of 384 patients with clinical stage I-II primary melanoma who underwent locorregional lymph node ultrasound (with or without ultrasound-guided biopsy) prior to SLNB between 2004 and 2015. We evaluated the reliability and cost-effectiveness of the strategy. Use of locorregional lymph node ultrasound avoided SLNB in 23 patients (6%). Ultrasound had a sensitivity of 46% and specificity of 76% for the detection of metastatic lymph nodes that were not clinically palpable. False negatives were significantly more common in patients aged over 60 years and in tumors with a thickness of less than 2mm. The staging process using SLNB and ultrasound with ultrasound-guided biopsy produced an increase of €16.30 in the unit price. Our cost-effectiveness analysis identified the staging protocol with ultrasound and SLNB as the dominant strategy, with a lower cost-effectiveness ratio than the alternative, consisting of SLNB alone (8,095.24 vs. €28,605.00). Ultrasound with ultrasound-guided biopsy for the diagnostic staging of melanoma prior to SLNB is a useful and cost-effective tool. This procedure does not substitute SLNB, though it does allow to avoid SLNB in a not insignificant proportion of patients. Copyright © 2017 AEDV. Publicado por Elsevier España, S.L.U. All rights reserved.

  3. Experience With Intravascular Ultrasound Imaging Of Human Atherosclerotic Arteries

    NASA Astrophysics Data System (ADS)

    Mallery, John A.; Gessert, James M.; Maciel, Mario; Tobis, John M.; Griffith, James M.; Berns, Michael W.; Henry, Walter L.

    1989-08-01

    Normal human arteries have a well-defined structure on intravascular images. The intima appears very thin and is most likely represented by a bright reflection arising from the internal elastic lamina. The smooth muscle tunica media is echo-lucent on the ultrasound image and appears as a dark band separating the intima from the adventitia. The adventitia is a brightly reflective layer of variable thickness. The thickness of the intima, and therefore of the atherosclerotic plaque can be accurately measured from the ultrasound images and correlates well with histology. Calcification within the wall of arteries is seen as bright echo reflection with shadowing of the peripheral wall. Fibrotic regions are highly reflective but do not shadow. Necrotic liquid regions within advanced atherosclerotic plaques are seen on ultrasound images as large lucent zones surrounded by echogenic tissue. Imaging can be performed before and after interventional procedures, such as laser angioplasty, balloon angioplasty and atherectomy. Intravascular ultrasound appears to provide an imaging modality for identifying the histologic characteristics of diseased arteries and for quantifying plaque thickness. It might be possible to perform such quantification to evaluate the results of interventional procedures.

  4. Teaching the internist to see: effectiveness of a 1-day workshop in bedside ultrasound for internal medicine residents.

    PubMed

    Clay, Ryan D; Lee, Elizabeth C; Kurtzman, Marc F; Dversdal, Renee K

    2016-12-01

    A growing body of evidence supports the use of bedside ultrasound for core Internal Medicine procedures and increasingly as augmentation of the physical exam. The literature also supports that trainees, both medical students and residents, can acquire these skills. However, there is no consensus on training approach. To implement and study the effectiveness of a high-yield and expedited curriculum to train internal medicine interns to use bedside ultrasound for physical examination and procedures. The study was conducted at a metropolitan, academic medical center and included 33 Internal Medicine interns. This was a prospective cohort study of a new educational intervention consisting of a single-day intensive bedside ultrasound workshop followed by two optional hour-long workshops later in the year. The investigation was conducted at Oregon Health & Science University in Portland, Oregon. The intensive day consisted of alternating didactic sessions with small group hands-on ultrasound practice sessions and ultrasound simulations. A 30-question assessment was used to assess ultrasound interpretation knowledge prior to, immediately post, and 6 months post intervention. Thirty-three interns served as their own historical controls. Assessment performance significantly increased after the intervention from a mean pre-test score of 18.3 (60.9 % correct) to a mean post-test score 25.5 (85.0 % correct), P value of <0.0001. This performance remained significantly better at 6 months with a mean score of 23.8 (79.3 % correct), P value <0.0001. There was significant knowledge attrition compared to the immediate post-assessment, P value 0.0099. A single-day ultrasound training session followed by two optional noon conference sessions yielded significantly improved ultrasound interpretation skills in internal medicine interns.

  5. Spatio-temporal control of gene expression and cancer treatment using magnetic resonance imaging-guided focused ultrasound.

    PubMed

    Moonen, Chrit T W

    2007-06-15

    Local temperature elevation may be used for tumor ablation, gene expression, drug activation, and gene and/or drug delivery. High-intensity focused ultrasound (HIFU) is the only clinically viable technology that can be used to achieve a local temperature increase deep inside the human body in a noninvasive way. Magnetic resonance imaging (MRI) guidance of the procedure allows in situ target definition and identification of nearby healthy tissue to be spared. In addition, MRI can be used to provide continuous temperature mapping during HIFU for spatial and temporal control of the heating procedure and prediction of the final lesion based on the received thermal dose. The primary purpose of the development of MRI-guided HIFU was to achieve safe noninvasive tissue ablation. The technique has been tested extensively in preclinical studies and is now accepted in the clinic for ablation of uterine fibroids. MRI-guided HIFU for ablation shows conceptual similarities with radiation therapy. However, thermal damage generally shows threshold-like behavior, with necrosis above the critical thermal dose and full recovery below. MRI-guided HIFU is being clinically evaluated in the cancer field. The technology also shows great promise for a variety of advanced therapeutic methods, such as gene therapy. MR-guided HIFU, together with the use of a temperature-sensitive promoter, provides local, physical, and spatio-temporal control of transgene expression. Specially designed contrast agents, together with the combined use of MRI and ultrasound, may be used for local gene and drug delivery.

  6. Fully Automated Prostate Magnetic Resonance Imaging and Transrectal Ultrasound Fusion via a Probabilistic Registration Metric.

    PubMed

    Sparks, Rachel; Bloch, B Nicolas; Feleppa, Ernest; Barratt, Dean; Madabhushi, Anant

    2013-03-08

    In this work, we present a novel, automated, registration method to fuse magnetic resonance imaging (MRI) and transrectal ultrasound (TRUS) images of the prostate. Our methodology consists of: (1) delineating the prostate on MRI, (2) building a probabilistic model of prostate location on TRUS, and (3) aligning the MRI prostate segmentation to the TRUS probabilistic model. TRUS-guided needle biopsy is the current gold standard for prostate cancer (CaP) diagnosis. Up to 40% of CaP lesions appear isoechoic on TRUS, hence TRUS-guided biopsy cannot reliably target CaP lesions and is associated with a high false negative rate. MRI is better able to distinguish CaP from benign prostatic tissue, but requires special equipment and training. MRI-TRUS fusion, whereby MRI is acquired pre-operatively and aligned to TRUS during the biopsy procedure, allows for information from both modalities to be used to help guide the biopsy. The use of MRI and TRUS in combination to guide biopsy at least doubles the yield of positive biopsies. Previous work on MRI-TRUS fusion has involved aligning manually determined fiducials or prostate surfaces to achieve image registration. The accuracy of these methods is dependent on the reader's ability to determine fiducials or prostate surfaces with minimal error, which is a difficult and time-consuming task. Our novel, fully automated MRI-TRUS fusion method represents a significant advance over the current state-of-the-art because it does not require manual intervention after TRUS acquisition. All necessary preprocessing steps (i.e. delineation of the prostate on MRI) can be performed offline prior to the biopsy procedure. We evaluated our method on seven patient studies, with B-mode TRUS and a 1.5 T surface coil MRI. Our method has a root mean square error (RMSE) for expertly selected fiducials (consisting of the urethra, calcifications, and the centroids of CaP nodules) of 3.39 ± 0.85 mm.

  7. Approach for chronic total occlusion with intravascular ultrasound-guided reverse controlled antegrade and retrograde tracking technique: single center experience.

    PubMed

    Dai, Jian; Katoh, Osamu; Kyo, Eisho; Tsuji, Takafumi; Watanabe, Satoshi; Ohya, Hidefumi

    2013-10-01

    Controlled antegrade and retrograde subintimal tracking (CART) or reverse CART techniques is the final step for percutaneous revascularization of coronary chronic total occlusion (CTO), but it still represents technical challenges and risk in interventional procedures. Our purpose was to utilize intravascular ultrasound (IVUS)-guided reverse CART approach for percutaneous revascularization of CTO in our heart center, focusing on its safety, efficacy, and latest technical developments. From November 2006 to November 2012, 49 patients with CTO failed to antegrade and/or retrograde percutaneous revascularization of CTO from true lumen to true lumen were enrolled in and underwent IVUS guided reverse CART approach. The mean J-CTO score of cases was 2.5. IVUS guidance was successfully implemented in 95.9%; IVUS identified that 61.7% of retrograde wires were located at intimal space, and 59.5% of antegrade wires were located at subintimal space. A Corsair channel dilator was used in 77.6% of cases. The success rates of technique and procedure were 95.9% and 93.9%, respectively; the technical minor complications were observed in 10.2% of cases, without significant clinic outcomes; 2.0% of cases occurred with a major adverse cardiac event of non-ST-elevation myocardial infarction; and no case occurred with target vessel revascularization or death. The mean length of stent implanted in a single CTO vessel was 51.3 mm. No patient appeared with radiation dermatitis and contrast-induced rise of creatinine. IVUS guided reverse CART approach is effective and safe for percutaneous revascularization of complex CTO, with a high success and a low complication rate. It is feasible to develop this approach for percutaneous revascularization of complex CTO. However, suitable case selection and lately device handling by experienced operators are the crucial points of success. © 2013, Wiley Periodicals, Inc.

  8. Neurologic Outcomes After Low-Volume, Ultrasound-Guided Interscalene Block and Ambulatory Shoulder Surgery.

    PubMed

    Rajpal, Gaurav; Winger, Daniel G; Cortazzo, Megan; Kentor, Michael L; Orebaugh, Steven L

    2016-01-01

    Postoperative neurologic symptoms after interscalene block and shoulder surgery have been reported to be relatively frequent. Reports of such symptoms after ultrasound-guided block have been variable. We evaluated 300 patients for neurologic symptoms after low-volume, ultrasound-guided interscalene block and arthroscopic shoulder surgery. Patients underwent ultrasound-guided interscalene block with 16 to 20 mL of 0.5% bupivacaine or a mix of 0.2% bupivacaine/1.2% mepivacaine solution, followed by propofol/ketamine sedation for ambulatory arthroscopic shoulder surgery. Patients were called at 10 days for evaluation of neurologic symptoms, and those with persistent symptoms were called again at 30 days, at which point neurologic evaluation was initiated. Details of patient demographics and block characteristics were collected to assess any association with persistent neurologic symptoms. Six of 300 patients reported symptoms at 10 days (2%), with one of these patients having persistent symptoms at 30 days (0.3%). This was significantly lower than rates of neurologic symptoms reported in preultrasound investigations with focused neurologic follow-up and similar to other studies performed in the ultrasound era. There was a modest correlation between the number of needle redirections during the block procedure and the presence of postoperative neurologic symptoms. Ultrasound guidance of interscalene block with 16- to 20-mL volumes of local anesthetic solution results in a lower frequency of postoperative neurologic symptoms at 10 and 30 days as compared with investigations in the preultrasound period.

  9. MO-DE-202-02: Advances in Image Registration and Reconstruction for Image-Guided Neurosurgery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Siewerdsen, J.

    At least three major trends in surgical intervention have emerged over the last decade: a move toward more minimally invasive (or non-invasive) approach to the surgical target; the development of high-precision treatment delivery techniques; and the increasing role of multi-modality intraoperative imaging in support of such procedures. This symposium includes invited presentations on recent advances in each of these areas and the emerging role for medical physics research in the development and translation of high-precision interventional techniques. The four speakers are: Keyvan Farahani, “Image-guided focused ultrasound surgery and therapy” Jeffrey H. Siewerdsen, “Advances in image registration and reconstruction for image-guidedmore » neurosurgery” Tina Kapur, “Image-guided surgery and interventions in the advanced multimodality image-guided operating (AMIGO) suite” Raj Shekhar, “Multimodality image-guided interventions: Multimodality for the rest of us” Learning Objectives: Understand the principles and applications of HIFU in surgical ablation. Learn about recent advances in 3D–2D and 3D deformable image registration in support of surgical safety and precision. Learn about recent advances in model-based 3D image reconstruction in application to intraoperative 3D imaging. Understand the multi-modality imaging technologies and clinical applications investigated in the AMIGO suite. Understand the emerging need and techniques to implement multi-modality image guidance in surgical applications such as neurosurgery, orthopaedic surgery, vascular surgery, and interventional radiology. Research supported by the NIH and Siemens Healthcare.; J. Siewerdsen; Grant Support - National Institutes of Health; Grant Support - Siemens Healthcare; Grant Support - Carestream Health; Advisory Board - Carestream Health; Licensing Agreement - Carestream Health; Licensing Agreement - Elekta Oncology.; T. Kapur, P41EB015898; R. Shekhar, Funding: R42CA137886 and R41CA192504 Disclosure and CoI: IGI Technologies, small-business partner on the grants.« less

  10. Ultrasound-guided synovial Tru-cut biopsy: indications, technique, and outcome in 111 cases.

    PubMed

    Sitt, Jacqueline C M; Griffith, James F; Lai, Fernand M; Hui, Mamie; Chiu, K H; Lee, Ryan K L; Ng, Alex W H; Leung, Jason

    2017-05-01

    To investigate the diagnostic performance of ultrasound-guided synovial biopsy. Clinical notes, pathology and microbiology reports, ultrasound and other imaging studies of 100 patients who underwent 111 ultrasound-guided synovial biopsies were reviewed. Biopsies were compared with the final clinical diagnosis established after synovectomy (n = 43) or clinical/imaging follow-up (n = 57) (mean 30 months). Other than a single vasovagal episode, no complication of synovial biopsy was encountered. One hundred and seven (96 %) of the 111 biopsies yielded synovium histologically. Pathology ± microbiology findings for these 107 conclusive biopsies comprised synovial tumour (n = 30, 28 %), synovial infection (n = 18, 17 %), synovial inflammation (n = 45, 42 %), including gouty arthritis (n = 3), and no abnormality (n = 14, 13 %). The accuracy, sensitivity, and specificity of synovial biopsy was 99 %, 97 %, and 100 % for synovial tumour; 100 %, 100 %, and 100 % for native joint infection; and 78 %, 45 %, and 100 % for prosthetic joint infection. False-negative synovial biopsy did not seem to be related to antibiotic therapy. Ultrasound-guided Tru-cut synovial biopsy is a safe and reliable technique with a high diagnostic yield for diagnosing synovial tumour and also, most likely, for joint infection. Regarding joint infection, synovial biopsy of native joints seems to have a higher diagnostic yield than that for infected prosthetic joints. • Ultrasound-guided Tru-cut synovial biopsy has high accuracy (99 %) for diagnosing synovial tumour. • It has good accuracy, sensitivity, and high specificity for diagnosis of joint infection. • Synovial biopsy of native joints works better than biopsy of prosthetic joints. • A negative synovial biopsy culture from a native joint largely excludes septic arthritis. • Ultrasound-guided Tru-cut synovial biopsy is a safe and well-tolerated procedure.

  11. Adopting Ultrasound Guidance for Prone Percutaneous Nephrolithotomy: Evaluating the Learning Curve for the Experienced Surgeon

    PubMed Central

    Usawachintachit, Manint; Masic, Selma; Allen, Isabel E.; Li, Jianxing

    2016-01-01

    Abstract Objectives: To define the learning curve associated with adopting ultrasound guidance for prone percutaneous nephrolithotomy (PCNL) for the experienced surgeon. Methods: A prospective cohort study of consecutive patients undergoing PCNL with ultrasound guidance for renal tract access and dilation was performed. Clinical data reviewed included success in gaining renal access with ultrasound guidance, total fluoroscopic screening time, and radiation exposure dose. PCNL cases performed with fluoroscopic guidance matched for stone size served as control cases. Results: One hundred consecutive ultrasound-guided procedures performed by a single experienced endourologist were divided into five experience groups. Significant improvement in renal access success rate with ultrasound was seen after 20 cases (p < 0.05). Total fluoroscopic screening time, radiation exposure dose, and operative time were also statistically significantly improved over the study period. When compared with fluoroscopy-guided PCNL, significant decreases in total fluoroscopic screening time (33.4 ± 35.3 seconds vs 157.5 ± 84.9 seconds, p < 0.05) and radiation exposure (7.0 ± 8.7 mGy vs 47.8 ± 45.9 mGy, p < 0.05) were seen. No differences in complication rates were found. Conclusions: Ultrasound-guided renal access for PCNL can be performed effectively after 20 cases. Transition to the use of ultrasound will quickly reduce radiation exposure for patients and intraoperative personnel. PMID:27150671

  12. Ultrasound-Guided Breast Biopsy

    MedlinePlus

    ... the type of biopsy being performed or the design of the biopsy machine, a biopsy of tissue ... cost information. The costs for specific medical imaging tests, treatments and procedures may vary by geographic region. ...

  13. Does ultrasound-guided lidocaine injection improve local anaesthesia before femoral artery catheterization?

    PubMed

    Spiliopoulos, S; Katsanos, K; Diamantopoulos, A; Karnabatidis, D; Siablis, D

    2011-05-01

    To present the results of a prospective, randomized, single-centre study investigating local anaesthesia before percutaneous common femoral artery (CFA) puncture and catheterization with the use of ultrasound-guided injection of lidocaine versus standard infiltration by manual palpation. Patients scheduled to undergo diagnostic or therapeutic transfemoral catheter-based procedures gave informed consent and were randomized in two groups. In the first arm local anaesthesia with lidocaine hydrochloride 1% was performed under ultrasound guidance (group U/S), while in the second arm the standard method of manual artery palpation was applied (group M). In both groups, subsequent CFA catheterization was achieved under ultrasound guidance. The primary study endpoint was peri-procedural pain level evaluated with a visual-analogue scale (VAS score 0-10). Between January 2009 and 2010, 200 patients (161 men, mean age 63±12 years) were equally assigned to each group without any significant differences in baseline demographics. Patients in group U/S experienced significantly less pain during CFA catheterization in comparison with group M with a difference of three points in mean VAS score reported (1.6±1.6 versus 4.6±1.9, p<0.0001). In addition, significantly less volume of lidocaine was used in group U/S compared to group M (16±2.7 versus 19±0.8ml, p<0.001).Total vascular access time was similar in both groups (4.4±1.3 versus 4.5±1.3min). Overall complications included two small groin haematomas in each group. Ultrasound-guided local anaesthesia of the CFA prior to percutaneous transcatheter procedures is safe and achieves superior levels of analgesia with minimal patient pain and discomfort compared to the standard method of manual palpation. Copyright © 2011 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  14. Two Cases of Lethal Complications Following Ultrasound-Guided Percutaneous Fine-Needle Biopsy of the Liver

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Drinkovic, Ivan; Brkljacic, Boris

    1996-09-15

    Two cases with lethal complications are reported among 1750 ultrasound (US)-guided percutaneous fine-needle liver biopsies performed in our department. The first patient had angiosarcoma of the liver which was not suspected after computed tomography (CT) and US studies had been performed. The other patient had hepatocellular carcinoma in advanced hepatic cirrhosis. Death was due to bleeding in both cases. Pre-procedure laboratory tests did not reveal the existence of major bleeding disorders in either case. Normal liver tissue was interposed in the needle track between the liver capsule and the lesions which were targeted.

  15. Treatment of Partial Rotator Cuff Tear with Ultrasound-guided Platelet-rich Plasma.

    PubMed

    Sengodan, Vetrivel Chezian; Kurian, Sajith; Ramasamy, Raghupathy

    2017-01-01

    The treatment of symptomatic partial rotator cuff tear has presented substantial challenge to orthopaedic surgeons as it can vary from conservative to surgical repair. Researches have established the influence of platelet rich plasma in healing damaged tissue. Currently very few data are available regarding the evidence of clinical and radiological outcome of partial rotator cuff tear treated with ultrasound guided platelet rich plasma injection in English literature. 20 patients with symptomatic partial rotator cuff tears were treated with ultrasound guided platelet rich plasma injection. Before and after the injection of platelet rich plasma scoring was done with visual analogue score, Constant shoulder score, and UCLA shoulder score at 8 weeks and third month. A review ultrasound was performed 8 weeks after platelet rich plasma injection to assess the rotator cuff status. Our study showed statistically significant improvements in 17 patients in VAS pain score, constant shoulder score and UCLA shoulder score. No significant changes in ROM were noted when matched to the contra-lateral side ( P < 0.001) at the 3 month follow-up. The study also showed good healing on radiological evaluation with ultrasonogram 8 weeks after platelet rich plasma injection. Ultrasound guided platelet rich plasma injection for partial rotator cuff tears is an effective procedure that leads to significant decrease in pain, improvement in shoulder functions, much cost-effective and less problematic compared to a surgical treatment.

  16. Comparison of a GPS needle-tracking system, multiplanar imaging and 2D imaging for real-time ultrasound-guided epidural anaesthesia: A randomized, comparative, observer-blinded study on phantoms.

    PubMed

    Menacé, Cécilia; Choquet, Olivier; Abbal, Bertrand; Bringuier, Sophie; Capdevila, Xavier

    2017-04-01

    The real-time ultrasound-guided paramedian sagittal oblique approach for neuraxial blockade is technically demanding. Innovative technologies have been developed to improve nerve identification and the accuracy of needle placement. The aim of this study was to evaluate three types of ultrasound scans during ultrasound-guided epidural lumbar punctures in a spine phantom. Eleven sets of 20 ultrasound-guided epidural punctures were performed with 2D, GPS, and multiplanar ultrasound machines (660 punctures) on a spine phantom using an in-plane approach. For all punctures, execution time, number of attempts, bone contacts, and needle redirections were noted by an independent physician. Operator comfort and visibility of the needle (tip and shaft) were measured using a numerical scale. The use of GPS significantly decreased the number of punctures, needle repositionings, and bone contacts. Comfort of the physician was also significantly improved with the GPS system compared with the 2D and multiplanar systems. With the multiplanar system, the procedure was not facilitated and execution time was longer compared with 2D imaging after Bonferroni correction but interaction between the type of ultrasound system and mean execution time was not significant in a linear mixed model. There were no significant differences regarding needle tip and shaft visibility between the systems. Multiplanar and GPS needle-tracking systems do not reduce execution time compared with 2D imaging using a real-time ultrasound-guided paramedian sagittal oblique approach in spine phantoms. The GPS needle-tracking system can improve performance in terms of operator comfort, the number of attempts, needle redirections and bone contacts. Copyright © 2016 Société française d'anesthésie et de réanimation (Sfar). Published by Elsevier Masson SAS. All rights reserved.

  17. Radial access for cerebrovascular procedures: Case report and technical note.

    PubMed

    Satti, Sudhakar R; Vance, Ansar Z; Sivapatham, Thinesh

    2016-04-01

    Advantages of radial access over brachial/axillary or femoral access have been well described for several decades and include decreased cost, patient preference, and decreased major access site complications. Despite these advantages, radial access is rarely employed or even considered for neurointerventional procedures. This attitude should be reconsidered given several recent large, randomized, controlled trials from the cardiovascular literature proving that radial access is associated with statistically lower costs, decreased incidence of myocardial infarctions, strokes, and even decreased mortality. Radial access is now considered the standard of care for percutaneous coronary interventions in most US centers. Although radial access has been described for neurovascular procedures in the past, overall experience is limited. The two major challenges are the unique anatomy required to access the cerebral vasculature given very acute angles between the arm and craniocervical vessels and limitations in available technology. We present a simplified approach to radial access for cerebrovascular procedures and provide a concise step-by-step approach for patient selection, ultrasound-guided single-wall access, recommended catheters/wires, and review of patent hemostasis. Additionally, we present a complex cerebrovascular intervention in which standard femoral access was unsuccessful, while radial access was quickly achieved to highlight the importance of familiarity with the radial approach for all neurointerventionalists. We have found that the learning curve is not too steep and that the radial access approach can be adopted smoothly for a large percentage of diagnostic and interventional neuroradiologic procedures. Radial access should be considered in all patients undergoing a cerebrovascular procedure. © The Author(s) 2015.

  18. Is Intra-Articular Steroid Injection to the Temporomandibular Joint for Juvenile Idiopathic Arthritis More Effective and Efficient When Performed With Image Guidance?

    PubMed

    Resnick, Cory M; Vakilian, Pouya M; Kaban, Leonard B; Peacock, Zachary S

    2017-04-01

    To compare short-term outcomes and procedure times for intra-articular steroid injection (IASI) to the temporomandibular joint (TMJ) with and without the use of intraoperative image guidance for patients with juvenile idiopathic arthritis (JIA). This is a retrospective study of children with JIA who underwent TMJ IASI at Boston Children's Hospital (Boston, MA). Patients were divided into groups according to IASI technique: 1) "landmark" group if performed by an oral and maxillofacial surgeon using an anatomic landmark technique with no intraoperative image guidance or 2) "image-guided" group if performed by an interventional radiologist using intraoperative ultrasound and computed tomography. Predictor variables included IASI technique (landmark vs image guided), age, gender, JIA subtype, category of medications for arthritis, and presence of family history of autoimmune disease. Outcome variables were changes in patient-reported pain, maximal incisal opening (MIO), synovial enhancement ratio (ER), and total procedure time. Forty-five patients with 71 injected TMJs were included. Twenty-two patients with 36 injected TMJs were in the landmark group and 23 patients with 35 injected joints were in the image-guided group. There were no relevant differences in age, gender, family history of rheumatologic disease, or disease subtype between groups. There were no differences in resolution of pain (P = 1.00), increase in MIO (P = .975), or decrease in ER (P = .492) between groups, but procedure times averaged 49 minutes longer for the image-guided group (P < .008). There were no statistical differences in short-term outcomes, but procedure times were longer for the image-guided group. Although specific indications for the use of image guidance might exist, routine use of this procedure cannot be justified. Copyright © 2016 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  19. Mediastinal abscess after endobronchial ultrasound-guided transbronchial needle aspiration: a case report and literature review.

    PubMed

    Leong, Steven C; Marshall, Henry M; Bint, Michael; Yang, Ian A; Bowman, Rayleen V; Fong, Kwun M

    2013-10-01

    Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a minimally invasive technique that allows lung cancer nodal staging and biopsy of parabronchial and paratracheal tissue. Its simplicity, high diagnostic yield, ability to diagnose both benign and malignant conditions, and exceedingly low complication rate has resulted in rapid widespread adoption by surgeons and physicians. EBUS-TBNA-related complications, however, do occur and need to be considered when assessing the risk-benefit profile of performing the procedure, and if the patient represents with unexpected symptoms after the procedure. We describe a 64-year-old woman who presented with a mediastinal abscess 5 days after EBUS-TBNA. This case demonstrates the importance of considering EBUS-TBNA-related complications to guide relevant imaging decisions and antibiotic choices. We review the published literature regarding infective complications of EBUS-TBNA and propose possible pathophysiologies. These complications are likely to increase in frequency as the technique is more widely adopted.

  20. Addition of Ceftriaxone and Amikacin to a Ciprofloxacin plus Metronidazole Regimen for Preventing Infectious Complications of Transrectal Ultrasound-Guided Prostate Biopsy: A Randomized Controlled Trial

    PubMed Central

    Izadpanahi, Mohammad-Hossein; Majidi, Seyed Mahmood; Khorrami, Mohammad-Hatef; Mohammadi-Sichani, Mehrdad

    2017-01-01

    Background. The objective of this study was to evaluate the efficacy of adding single doses of ceftriaxone and amikacin to a ciprofloxacin plus metronidazole regimen on the reduction of infectious complications following transrectal ultrasound-guided prostate biopsy (TRUS Bx). Materials and Methods. Four hundred and fifty patients who were candidates for TRUS Bx were divided into two groups of 225 each. The control group received ciprofloxacin 500 mg orally every 12 hours together with metronidazole 500 mg orally every 8 hours from the day prior to the procedure until the fifth postoperative day. In the second group, single doses of ceftriaxone 1 g by intravenous infusion and amikacin 5 mg/kg intramuscularly were administered 30–60 minutes before TRUS Bx in addition to the oral antimicrobials described for group 1. The incidence of infection was compared between the groups. Results. The incidence of infectious complications in the intervention group was significantly lower than that in the control group (4.6% versus 0.9%, p = 0.017). Conclusion. The addition of single doses of intramuscular amikacin and intravenously infused ceftriaxone to our prophylactic regimen of ciprofloxacin plus metronidazole resulted in a statistically significant reduction of infectious complications following TRUS Bx. PMID:28167960

  1. Addition of Ceftriaxone and Amikacin to a Ciprofloxacin plus Metronidazole Regimen for Preventing Infectious Complications of Transrectal Ultrasound-Guided Prostate Biopsy: A Randomized Controlled Trial.

    PubMed

    Izadpanahi, Mohammad-Hossein; Nouri-Mahdavi, Kia; Majidi, Seyed Mahmood; Khorrami, Mohammad-Hatef; Alizadeh, Farshid; Mohammadi-Sichani, Mehrdad

    2017-01-01

    Background. The objective of this study was to evaluate the efficacy of adding single doses of ceftriaxone and amikacin to a ciprofloxacin plus metronidazole regimen on the reduction of infectious complications following transrectal ultrasound-guided prostate biopsy (TRUS Bx). Materials and Methods. Four hundred and fifty patients who were candidates for TRUS Bx were divided into two groups of 225 each. The control group received ciprofloxacin 500 mg orally every 12 hours together with metronidazole 500 mg orally every 8 hours from the day prior to the procedure until the fifth postoperative day. In the second group, single doses of ceftriaxone 1 g by intravenous infusion and amikacin 5 mg/kg intramuscularly were administered 30-60 minutes before TRUS Bx in addition to the oral antimicrobials described for group 1. The incidence of infection was compared between the groups. Results. The incidence of infectious complications in the intervention group was significantly lower than that in the control group (4.6% versus 0.9%, p = 0.017). Conclusion. The addition of single doses of intramuscular amikacin and intravenously infused ceftriaxone to our prophylactic regimen of ciprofloxacin plus metronidazole resulted in a statistically significant reduction of infectious complications following TRUS Bx.

  2. In-line positioning of ultrasound images using wireless remote display system with tablet computer facilitates ultrasound-guided radial artery catheterization.

    PubMed

    Tsuchiya, Masahiko; Mizutani, Koh; Funai, Yusuke; Nakamoto, Tatsuo

    2016-02-01

    Ultrasound-guided procedures may be easier to perform when the operator's eye axis, needle puncture site, and ultrasound image display form a straight line in the puncture direction. However, such methods have not been well tested in clinical settings because that arrangement is often impossible due to limited space in the operating room. We developed a wireless remote display system for ultrasound devices using a tablet computer (iPad Mini), which allows easy display of images at nearly any location chosen by the operator. We hypothesized that the in-line layout of ultrasound images provided by this system would allow for secure and quick catheterization of the radial artery. We enrolled first-year medical interns (n = 20) who had no prior experience with ultrasound-guided radial artery catheterization to perform that using a short-axis out-of-plane approach with two different methods. With the conventional method, only the ultrasound machine placed at the side of the head of the patient across the targeted forearm was utilized. With the tablet method, the ultrasound images were displayed on an iPad Mini positioned on the arm in alignment with the operator's eye axis and needle puncture direction. The success rate and time required for catheterization were compared between the two methods. Success rate was significantly higher (100 vs. 70 %, P = 0.02) and catheterization time significantly shorter (28.5 ± 7.5 vs. 68.2 ± 14.3 s, P < 0.001) with the tablet method as compared to the conventional method. An ergonomic straight arrangement of the image display is crucial for successful and quick completion of ultrasound-guided arterial catheterization. The present remote display system is a practical method for providing such an arrangement.

  3. CT-Guided Superior Vena Cava Puncture: A Solution to Re-Establishing Access in Haemodialysis-Related Central Venous Occlusion Refractory to Conventional Endovascular Techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Khalifa, Mohamed, E-mail: mkhalifa@nhs.net; Patel, Neeral R., E-mail: neeral.patel06@gmail.com; Moser, Steven, E-mail: steven.moser@imperial.nhs.uk

    PurposeThe purpose of this technical note is to demonstrate the novel use of CT-guided superior vena cava (SVC) puncture and subsequent tunnelled haemodialysis (HD) line placement in end-stage renal failure (ESRF) patients with central venous obstruction refractory to conventional percutaneous venoplasty (PTV) and wire transgression, thereby allowing resumption of HD.MethodsThree successive ESRF patients underwent CT-guided SVC puncture with subsequent tract recanalisation. Ultrasound-guided puncture of the right internal jugular vein was performed, the needle advanced to the patent SVC under CT guidance, with subsequent insertion of a stabilisation guidewire. Following appropriate tract angioplasty, twin-tunnelled HD catheters were inserted and HD resumed.ResultsNomore » immediate complications were identified. There was resumption of HD in all three patients with a 100 % success rate. One patient’s HD catheter remained in use for 2 years post-procedure, and another remains functional 1 year to the present day. One patient died 2 weeks after the procedure due to pancreatitis-related abdominal sepsis unrelated to the Tesio lines.ConclusionCT-guided SVC puncture and tunnelled HD line insertion in HD-related central venous occlusion (CVO) refractory to conventional recanalisation options can be performed safely, requires no extra equipment and lies within the skill set and resources of most interventional radiology departments involved in the management of HD patients.« less

  4. Image-guided percutaneous removal of ballistic foreign bodies secondary to air gun injuries.

    PubMed

    Rothermund, Jacob L; Rabe, Andrew J; Zumberge, Nicholas A; Murakami, James W; Warren, Patrick S; Hogan, Mark J

    2018-01-01

    Ballistic injuries with retained foreign bodies from air guns is a relatively common problem, particularly in children and adolescents. If not removed in a timely fashion, the foreign bodies can result in complications, including pain and infection. Diagnostic methods to identify the presence of the foreign body run the entire gamut of radiology, particularly radiography, ultrasound (US) and computed tomography (CT). Removal of the foreign bodies can be performed by primary care, emergency, surgical, and radiologic clinicians, with or without imaging guidance. To evaluate the modalities of radiologic detection and the experience of image-guided ballistic foreign body removal related to air gun injuries within the interventional radiology department of a large pediatric hospital. A database of more than 1,000 foreign bodies that were removed with imaging guidance by the interventional radiologists at our institution was searched for ballistic foreign bodies from air guns. The location, dimensions, diagnostic modality, duration, complications and imaging modality used for removal were recorded. In addition, the use of sedation and anesthesia required for the procedures was also recorded. Sixty-one patients with ballistic foreign bodies were identified. All foreign bodies were metallic BBs or pellets. The age of the patients ranged from 5 to 20 years. The initial diagnostic modality to detect the foreign bodies was primarily radiography. The primary modality to assist in removal was US, closely followed by fluoroscopy. For the procedure, 32.7% of the patients required some level of sedation. Only two patients had an active infection at the time of the removal. The foreign bodies were primarily in the soft tissues; however, successful removal was also performed from intraosseous, intraglandular and intratendinous locations. All cases resulted in successful removal without complications. Image-guided removal of ballistic foreign bodies secondary to air guns is a very effective procedure that can obviate the need for open surgical procedures in children.

  5. Image Fusion During Vascular and Nonvascular Image-Guided Procedures☆

    PubMed Central

    Abi-Jaoudeh, Nadine; Kobeiter, Hicham; Xu, Sheng; Wood, Bradford J.

    2013-01-01

    Image fusion may be useful in any procedure where previous imaging such as positron emission tomography, magnetic resonance imaging, or contrast-enhanced computed tomography (CT) defines information that is referenced to the procedural imaging, to the needle or catheter, or to an ultrasound transducer. Fusion of prior and intraoperative imaging provides real-time feedback on tumor location or margin, metabolic activity, device location, or vessel location. Multimodality image fusion in interventional radiology was initially introduced for biopsies and ablations, especially for lesions only seen on arterial phase CT, magnetic resonance imaging, or positron emission tomography/CT but has more recently been applied to other vascular and nonvascular procedures. Two different types of platforms are commonly used for image fusion and navigation: (1) electromagnetic tracking and (2) cone-beam CT. Both technologies would be reviewed as well as their strengths and weaknesses, indications, when to use one vs the other, tips and guidance to streamline use, and early evidence defining clinical benefits of these rapidly evolving, commercially available and emerging techniques. PMID:23993079

  6. Pilot study of intraoperative ultrasound-guided instrument placement in nerve transection surgery for peripheral nerve pain syndromes.

    PubMed

    Henning, P Troy; Wilson, Thomas J; Willsey, Matthew; John, Jessin K; Popadich, Miriana; Yang, Lynda J S

    2017-03-01

    Surgical transection of sensory nerves in the treatment of intractable neuropathic pain is a commonly performed procedure. At times these cases can be particularly challenging when encountering obese patients, when targeting deeper nerves or those with a variable branching pattern, or in the case of repeat operations. In this case series, the authors describe their experience with ultrasound-guided surgical instrument placement during transection of a saphenous nerve in the region of prior vascular surgery in 1 patient and in the lateral femoral cutaneous nerve in 2 obese patients. The authors also describe this novel technique and provide pilot data that suggests ultrasound-assisted surgery may allow for complex cases to be completed in an expedited fashion through smaller incisions.

  7. Chronic abdominal wall pain and ultrasound-guided abdominal cutaneous nerve infiltration: a case series.

    PubMed

    Kanakarajan, Saravanakumar; High, Kristina; Nagaraja, Ravi

    2011-03-01

    Chronic abdominal wall pain occurs in about 10-30% of patients presenting with chronic abdominal pain. Entrapment of abdominal cutaneous nerves at the lateral border of the rectus abdominis muscle has been attributed as a cause of abdominal wall pain. We report our experience of treating such patients using ultrasound-guided abdominal cutaneous nerve infiltration. We conducted a retrospective audit of abdominal cutaneous nerve infiltration performed in the period between September 2008 to August 2009 in our center. All patients had received local anesthetic and steroid injection under ultrasound guidance. The response to the infiltration was evaluated in the post-procedure telephone review as well as in the follow-up clinic. Brief pain inventory (BPI) and numerical rating scale pain scores were collated from two points: the initial outpatient clinic and the follow up clinic up to 5 months following the injection. Nine patients had abdominal cutaneous nerve injections under ultrasound guidance in the period under review. Six patients reported 50% pain relief or more (responders) while three patients did not. Pain and BPI scores showed a decreasing trend in responders. The median duration of follow-up was 12 weeks. Ultrasound can reliably be used for infiltration of the abdominal cutaneous nerves. This will improve the safety as well as diagnostic utility of the procedure. Wiley Periodicals, Inc.

  8. Cell-block procedure in endoscopic ultrasound-guided-fine-needle-aspiration of gastrointestinal solid neoplastic lesions

    PubMed Central

    Ieni, Antonio; Barresi, Valeria; Todaro, Paolo; Caruso, Rosario Alberto; Tuccari, Giovanni

    2015-01-01

    In the present review we have analyzed the clinical applications of endoscopic ultrasound-guided-fine-needle-aspiration (EUS-FNA) and the methodological aspects obtained by cell-block procedure (CBP) in the diagnostic approach to the gastrointestinal neoplastic pathology. CBP showed numerous advantages in comparison to the cytologic routine smears; in particular, better preservation of cell architecture, achievement of routine haematoxylin-eosin staining equivalent to histological slides and possibility to perform immunohistochemistry or molecular analyses represented the most evident reasons to choose this method. Moreover, by this approach, the differential diagnosis of solid gastrointestinal neoplasias may be more easily achieved and the background of contaminant non-neoplastic gastrointestinal avoided. Finally, biological samples collected by EUS-FNA CBP-assisted should be investigated in order to identify and quantify further potential molecular markers. PMID:26322154

  9. Lung flooding enables efficient lung sonography and tumour imaging in human ex vivo and porcine in vivo lung cancer model

    PubMed Central

    2013-01-01

    Background Sonography has become the imaging technique of choice for guiding intraoperative interventions in abdominal surgery. Due to artefacts from residual air content, however, videothoracoscopic and open intraoperative ultrasound-guided thermoablation of lung malignancies are impossible. Lung flooding is a new method that allows complete ultrasound imaging of lungs and their tumours. Methods Fourteen resected tumourous human lung lobes were examined transpleurally with B-mode ultrasound before (in atelectasis) and after lung flooding with isotonic saline solution. In two swine, the left lung was filled with 15 ml/kg isotonic saline solution through the left side of a double-lumen tube. Lung tumours were simulated by transthoracic ultrasound-guided injection of 5 ml of purified bovine serum albumin in glutaraldehyde, centrally into the left lower lung lobe. The rate of tumour detection, the severity of disability caused by residual gas, and sonomorphology of the lungs and tumours were assessed. Results The ex vivo tumour detection rate was 100% in flooded human lung lobes and 43% (6/14) in atelectatic lungs. In all cases of atelectasis, sonographic tumour imaging was impaired by residual gas. Tumours and atelectatic tissue were isoechoic. In 28% of flooded lungs, a little residual gas was observed that did not impair sonographic tumour imaging. In contrast to tumours, flooded lung tissue was hyperechoic, homogeneous, and of fine-grained structure. Because of the bronchial wall three-laminar structure, sonographic differentiation of vessels and bronchi was possible. In all cases, malignant tumours in the flooded lung appeared well-demarcated from the lung parenchyma. Adenocarcinoma, squamous, and large cell carcinomas were hypoechoic. Bronchioloalveolar cell carcinoma was slightly hyperechoic. Transpleural sonography identifies endobronchial tumour growth and bronchial wall destruction. With transthoracic sonography, the flooded animal lung can be completely examined in vivo. There is no residual gas, which interferes with ultrasound. Pulmonary vessels and bronchi are clearly differentiated. Simulated lung lesions can easily be detected inside the lung lobe. Conclusions Lung flooding enables complete lung sonography and tumour detection. We have developed a novel method that efficiently uses ultrasound for guiding intraoperative interventions in open and endoscopic lung surgery. PMID:23841910

  10. Post-procedure bleeding in interventional radiology.

    PubMed

    Mayer, J; Tacher, V; Novelli, L; Djabbari, M; You, K; Chiaradia, M; Deux, J-F; Kobeiter, H

    2015-01-01

    Following interventional radiology procedures, bleeding can occur in 0.5 to 4% of the cases. Risk factors are related to the patient, to the procedure, and to the end organ. Bleeding is treated usually by interventional radiologists and consists mainly of embolization. Bleeding complications are preventable: before the procedure by checking hemostasis, during the procedure by ensuring the accurate puncture site (with ultrasound or fluoroscopy guidance) or by treating the puncture path using gelatin sponge, curaspon(®), biological glue or thermocoagulation, and after the procedure by carefully monitoring the patients. Copyright © 2015 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  11. Safety of pediatric percutaneous liver biopsy performed by interventional radiologists.

    PubMed

    Potter, Carol; Hogan, Mark J; Henry-Kendjorsky, Katherine; Balint, Jane; Barnard, John A

    2011-08-01

    National data suggest that pediatric percutaneous liver biopsy is increasingly being performed by interventional radiologists rather than pediatric gastroenterologists. The objective of the present report is to describe the safety and effectiveness of percutaneous liver biopsy performed by interventional radiologists in a large cohort of children and to compare the results with the existing literature on biopsies performed by pediatric gastroenterologists. The medical records of 249 children undergoing ultrasound-guided percutaneous liver biopsy by interventional radiologists were reviewed for adverse events and success of obtaining tissue. Two hundred ninety-four biopsies were reviewed. There were no deaths. There were 2 instances of a 2-g or greater drop in hemoglobin following biopsy, neither of which was associated with clinical signs of hemorrhage. A small, asymptomatic pneumothorax quickly resolved without treatment. One patient developed Klebsiella sepsis 48  hours after biopsy. In all but 1 case, an adequate sample size was obtained. This low incidence of adverse events compares favorably with existing published reports of morbidity and mortality following percutaneous liver biopsy performed by pediatric gastroenterologists. Ultrasound-guided percutaneous liver biopsy performed by experienced pediatric interventional radiologists in a children's hospital setting is as safe and effective as biopsy performed by pediatric gastroenterologists.

  12. Application of a topical vapocoolant spray decreases pain at the site of initial intradermal anaesthetic injection during ultrasound-guided breast needle biopsy.

    PubMed

    Collado-Mesa, F; Net, J M; Arheart, K; Klevos, G A; Yepes, M M

    2015-09-01

    To assess whether the application of a topical vapocoolant spray immediately prior to initial intradermal anaesthetic injection during ultrasound-guided breast biopsy decreases pain at the site of the initial injection. In this institutional review board-approved, Health Insurance Portability and Accountability Act (HIPAA)-compliant study, 50 women aged 49.1 ± 1.6 years (mean ± standard error) were recruited and provided written informed consent. Participants served as their own controls and were blinded as to whether a topical vapocoolant spray or a placebo was used immediately prior to the initial local anaesthetic injection at two separate biopsy sites. With the exception of the application of vapocoolant or placebo, the entire ultrasound-guided procedure was performed according to a routine protocol. Participants recorded pain at initial injection site on a visual analogue scale. General linear mixed models for repeated measures analysis of variance and a 0.05 significance level were used. Application of topical vapocoolant spray was shown to significantly decrease pain at the site of initial intradermal anaesthetic injection as compared to placebo (p<0.001). Treatment effect was independent of age of the subject, race/ethnicity, operator, type of biopsy device, and histopathology result. No complications from vapocoolant spray use were reported. Application of a topical vapocoolant spray immediately prior to initial intradermal anaesthetic injection during ultrasound-guided breast biopsy significantly decreases pain at the site of the initial injection and could contribute to improve the patient's overall procedural experience. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  13. Open-source image registration for MRI-TRUS fusion-guided prostate interventions.

    PubMed

    Fedorov, Andriy; Khallaghi, Siavash; Sánchez, C Antonio; Lasso, Andras; Fels, Sidney; Tuncali, Kemal; Sugar, Emily Neubauer; Kapur, Tina; Zhang, Chenxi; Wells, William; Nguyen, Paul L; Abolmaesumi, Purang; Tempany, Clare

    2015-06-01

    We propose two software tools for non-rigid registration of MRI and transrectal ultrasound (TRUS) images of the prostate. Our ultimate goal is to develop an open-source solution to support MRI-TRUS fusion image guidance of prostate interventions, such as targeted biopsy for prostate cancer detection and focal therapy. It is widely hypothesized that image registration is an essential component in such systems. The two non-rigid registration methods are: (1) a deformable registration of the prostate segmentation distance maps with B-spline regularization and (2) a finite element-based deformable registration of the segmentation surfaces in the presence of partial data. We evaluate the methods retrospectively using clinical patient image data collected during standard clinical procedures. Computation time and Target Registration Error (TRE) calculated at the expert-identified anatomical landmarks were used as quantitative measures for the evaluation. The presented image registration tools were capable of completing deformable registration computation within 5 min. Average TRE was approximately 3 mm for both methods, which is comparable with the slice thickness in our MRI data. Both tools are available under nonrestrictive open-source license. We release open-source tools that may be used for registration during MRI-TRUS-guided prostate interventions. Our tools implement novel registration approaches and produce acceptable registration results. We believe these tools will lower the barriers in development and deployment of interventional research solutions and facilitate comparison with similar tools.

  14. Thermal fixation of swine liver tissue after magnetic resonance-guided high-intensity focused ultrasound ablation.

    PubMed

    Courivaud, Frédéric; Kazaryan, Airazat M; Lund, Alice; Orszagh, Vivian C; Svindland, Aud; Marangos, Irina Pavlik; Halvorsen, Per Steinar; Jebsen, Peter; Fosse, Erik; Hol, Per Kristian; Edwin, Bjørn

    2014-07-01

    The aim of this study was to investigate experimental conditions for efficient and controlled in vivo liver tissue ablation by magnetic resonance (MR)-guided high-intensity focused ultrasound (HIFU) in a swine model, with the ultimate goal of improving clinical treatment outcome. Histological changes were examined both acutely (four animals) and 1 wk after treatment (five animals). Effects of acoustic power and multiple sonication cycles were investigated. There was good correlation between target size and observed ablation size by thermal dose calculation, post-procedural MR imaging and histopathology, when temperature at the focal point was kept below 90°C. Structural histopathology investigations revealed tissue thermal fixation in ablated regions. In the presence of cavitation, mechanical tissue destruction occurred, resulting in an ablation larger than the target. Complete extra-corporeal MR-guided HIFU ablation in the liver is feasible using high acoustic power. Nearby large vessels were preserved, which makes MR-guided HIFU promising for the ablation of liver tumors adjacent to large veins. Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  15. Ultrasound-guided shoulder MR arthrography: comparison of rotator interval and posterior approach.

    PubMed

    Ogul, Hayri; Bayraktutan, Ummugulsum; Ozgokce, Mesut; Tuncer, Kutsi; Yuce, Ihsan; Yalcin, Ahmet; Pirimoglu, Berhan; Sagsoz, Erdem; Kantarci, Mecit

    2014-01-01

    The purpose of this study was to prospectively evaluate the two different ultrasound-guided injection techniques for magnetic resonance (MR) arthrography of the shoulder. This study included 100 patients [50 rotator interval group (n=50) vs. 50 posterior approach group (n=50)]. All procedures were performed by the same radiologist. The two injection techniques were compared. The discomfort during and after arthrography was evaluated. Extraarticular contrast media extravasation was graded according to the MRI findings. The number of injection attempts, effect of contrast media extravasation rate on diagnostic quality and procedure times were recorded. There were no significant difference between the posterior and rotator interval puncture groups with regard to pain (P=.915), procedure times (P=.401) or attempt scores (P=.182). There were significantly more contrast media extravasations with rotator interval approach than posterior approach (P<.05). Both techniques were successful and well tolerated by patients. Posterior injection technique provided a more effective route with decreased extravasation rate and easier approach compared to the rotator interval approach. © 2014.

  16. Realtime ultrasound guided percutaneous tracheostomy in emergency setting: the glass ceiling has been broken.

    PubMed

    Ravi, Parli Raghavan; Vijai, M N; Shouche, Sachin

    2017-01-01

    In recent years ultrasound guided percutaneous tracheostomy (USPCT) has become a routine practice in critical care units. Its safety and superiority over conventional percutaneous tracheostomy and bronchoscopic guided PCT is proven to be non-inferior in elective cases. However its role in emergency percutaneous tracheostomy has never been studied, since percutaneous tracheostomy itself remains an enigma in accessing emergency airway. There is no report of use of ultrasound guided percutaneous tracheostomy in emergency setting so far in the literature. We report our early experience with USPCT in emergency setting. Sixteen adult patients who required access to an emergency surgical airway after failure to accomplish emergency oro-tracheal intubation were the study population. Their airway was accessed by USPCT. Recorded data included clinical and demographic data including time taken to perform the procedure and complications. Short term and long term follow ups for a period of 2 years were done for the survivors. Twelve male and four female patients underwent the procedure and the average time of the procedure was 3.6 min with no failures nor conversions to surgical tracheostomy and no complications. The average oxygen saturation was 86% and average Glasgow coma scale was 8.4. This time period included the oxygen insufflation time. 10 patients were decannulated while six patients died due to the pathology of the disease itself. There were no complications in either short term or long term follow up. USPCT has a definitive role in emergency both in trauma and non-trauma setting. It is safe, feasible and faster in experienced hands. Use of USPCT in emergency setting has further narrowed the list of contraindications of percutaneous tracheostomy.

  17. Robotic active positioning for magnetic resonance-guided high-intensity focused ultrasound

    NASA Astrophysics Data System (ADS)

    Xiao, Xu; Huang, Zhihong; Volovick, Alexander; Melzer, Andreas

    2012-11-01

    Magnetic resonance (MR) guided High-intensity focused ultrasound (HIFU) is a noninvasive method producing thermal necrosis and cavitation at the position of tumors with high accuracy. Because the typical size of the high-intensity focused ultrasound focus are much smaller than the targeted tumor or other tissues, multiple sonications and focus repositioning become necessary for HIFU treatment. In order to reach a much wider range, manual repositioning or using MR compatible mechanical actuators could be used. The repositioning technique is a time consuming procedure because it needs a series of MR imaging to detect the transducer and markers preplaced on the mechanical devices. We combined an active tracking technique into the MR guided HIFU system. In this work, the robotic system used is the MR-compatible robotics from InnoMotion{trade mark, serif} (IBSMM, Engineering spol. s r.o. / Ltd, Czech) which is originally designed for MR-guided needle biopsy. The precision and positioning speed of the combined robotic HIFU system are evaluated in this study. Compared to the existing MR guided HIFU systems, the combined robotic system with active tracking techniques provides a potential that allows the HIFU treatment to operate in a larger spatial range and with a faster speed.

  18. Ultrasound-guided fine needle aspiration versus core needle biopsy: comparison of post-biopsy hematoma rates and risk factors.

    PubMed

    Chae, In Hye; Kim, Eun-Kyung; Moon, Hee Jung; Yoon, Jung Hyun; Park, Vivian Y; Kwak, Jin Young

    2017-07-01

    To compare post-biopsy hematoma rates between ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy, and to investigate risk factors for post-biopsy hematoma. A total of 5304 thyroid nodules which underwent ultrasound guided biopsy were included in this retrospective study. We compared clinical and US features between patients with and without post-biopsy hematoma. Associations between these features and post-biopsy hematoma were analyzed. Post-biopsy hematoma rate was 0.8% (43/5121) for ultrasound guided-fine needle aspiration and 4.9% (9/183) for ultrasound guided-core needle biopsy (P < 0.001). For ultrasound guided-fine needle aspiration, gender, age, size, presence of vascularity, and suspicious US features were not associated with post-biopsy hematoma according to experience level. Post-biopsy hematoma occurred significantly more with ultrasound guided-core needle biopsy (9/179, 5.0%) than with ultrasound guided-fine needle aspiration (9/1138, 0.8%) (P < 0.001) in experienced performers and ultrasound guided-core needle biopsy was the only significant risk factor for post-biopsy hematoma (adjusted Odds Ratio, 6.458, P < 0.001). Post-biopsy hematoma occurred significantly more in ultrasound guided-core needle biopsy than in ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy was the only independent factor of post-biopsy hematoma in thyroid nodules.

  19. Feasibility of ultrasound-guided epidural access at the lumbo-sacral space in dogs.

    PubMed

    Liotta, Annalisa; Busoni, Valeria; Carrozzo, Maria Valentina; Sandersen, Charlotte; Gabriel, Annick; Bolen, Géraldine

    2015-01-01

    Epidural injections are commonly performed blindly in veterinary medicine. The aims of this study were to describe the lumbosacral ultrasonographic anatomy and to assess the feasibility of an ultrasound-guided epidural injection technique in dogs. A cross sectional anatomic atlas of the lumbosacral region and ex vivo ultrasound images were obtained in two cadavers to describe the ultrasound anatomy and to identify the landmarks. Sixteen normal weight canine cadavers were used to establish two variations of the technique for direct ultrasound-guided injection, using spinal needles or epidural catheters. The technique was finally performed in two normal weight cadavers, in two overweight cadavers and in five live dogs with radiographic abnormalities resulting of the lumbosacral spine. Contrast medium was injected and CT was used to assess the success of the injection. The anatomic landmarks to carry out the procedure were the seventh lumbar vertebra, the iliac wings, and the first sacral vertebra. The target for directing the needle was the trapezoid-shaped echogenic zone between the contiguous articular facets of the lumbosacral vertebral canal visualized in a parasagittal plane. The spinal needle or epidural catheter was inserted in a 45° craniodorsal-caudoventral direction through the subcutaneous tissue and the interarcuate ligament until reaching the epidural space. CT examination confirmed the presence of contrast medium in the epidural space in 25/25 dogs, although a variable contamination of the subarachnoid space was also noted. Findings indicated that this ultrasound-guided epidural injection technique is feasible for normal weight and overweight dogs, with and without radiographic abnormalities of the spine. © 2014 American College of Veterinary Radiology.

  20. Ultrasound-guided, percutaneous peripheral nerve stimulation: technical note.

    PubMed

    Chan, Isaac; Brown, Anthony R; Park, Kenneth; Winfree, Christopher J

    2010-09-01

    Peripheral nerve stimulation is a form of neuromodulation that applies electric current to peripheral nerves to induce stimulation paresthesias within the painful areas. To report a method of ultrasound-guided, percutaneous peripheral nerve stimulation. This technique utilizes real-time imaging to avoid injury to adjacent vascular structures during minimally invasive placement of peripheral nerve stimulator electrodes. We describe a patient that presented with chronic, bilateral foot pain following multiple foot surgeries, for whom a comprehensive, pain management treatment strategy had failed. We utilized ultrasound-guided, percutaneous tibial nerve stimulation at a thigh level to provide durable pain relief on the right side, and open peripheral nerve stimulation on the left. The patient experienced appropriate stimulation paresthesias and excellent pain relief on the plantar aspect of the right foot with the percutaneous electrode. On the left side, we were unable to direct the stimulation paresthesias to the sole of the foot, despite multiple electrode repositionings. A subsequent, open placement of a left tibial nerve stimulator was performed. This revealed that the correct electrode position against the tibial nerve was immediately adjacent to the popliteal artery, and was thus not appropriate for percutaneous placement. We describe a method of ultrasound-guided peripheral nerve stimulation that avoids the invasiveness of electrode placement via an open procedure while providing excellent pain relief. We further describe limitations of the percutaneous approach when navigating close to large blood vessels, a situation more appropriately managed with open peripheral nerve stimulator placement. Ultrasound-guided placement may be considered for patients receiving peripheral nerve stimulators placed within the deep tissues, and not easily placed in a blind fashion.

  1. Ultrasound-Guided Pulsed Radiofrequency Stimulation of Posterior Tibial Nerve: A Potential Novel Intervention for Recalcitrant Plantar Fasciitis.

    PubMed

    Wu, Yung-Tsan; Chang, Chih-Ya; Chou, Yu-Ching; Yeh, Chun-Chang; Li, Tsung-Ying; Chu, Heng-Yi; Chen, Liang-Cheng

    2017-05-01

    To evaluate the therapeutic benefit of ultrasound-guided pulsed radiofrequency (PRF) stimulation at the posterior tibial nerve (PTN) in patients with recalcitrant plantar fasciitis (PF). A prospective, randomized, double-blinded, placebo-controlled trial (12-wk follow-up). Outpatient local medical center settings. Patients (N=36) with recalcitrant PF underwent randomization, and all were included in the final data analysis. Patients in the PRF group were treated with 1 dose of ultrasound-guided PRF stimulation at the PTN, and those in the control group received 1 dose of 2% lidocaine, 0.5mL, injected at the PTN under ultrasound guidance. The visual analog scale (first-step and overall pain), American Orthopedic Foot-Ankle Society (AOFAS) ankle-hindfoot scale, and ultrasonographic thickness of the plantar fascia were evaluated at 1, 4, 8, and 12 weeks after treatment. Thirty-six patients (20 feet per group) completed the study. The PRF group had a significantly larger improvement in first-step pain, overall pain, and AOFAS score (all P<.001), as well as plantar fascia thickness (P<.05), compared with those of the control group at all observed time points. This study shows that ultrasound-guided PRF stimulation at the PTN is effective for treating recalcitrant PF. This simple, reproducible method could be a novel strategy for managing recalcitrant PF. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  2. First noninvasive thermal ablation of a brain tumor with MR-guided focused ultrasound

    PubMed Central

    2014-01-01

    Magnetic resonance-guided focused ultrasound surgery (MRgFUS) allows for precise thermal ablation of target tissues. While this emerging modality is increasingly used for the treatment of various types of extracranial soft tissue tumors, it has only recently been acknowledged as a modality for noninvasive neurosurgery. MRgFUS has been particularly successful for functional neurosurgery, whereas its clinical application for tumor neurosurgery has been delayed for various technical and procedural reasons. Here, we report the case of a 63-year-old patient presenting with a centrally located recurrent glioblastoma who was included in our ongoing clinical phase I study aimed at evaluating the feasibility and safety of transcranial MRgFUS for brain tumor ablation. Applying 25 high-power sonications under MR imaging guidance, partial tumor ablation could be achieved without provoking neurological deficits or other adverse effects in the patient. This proves, for the first time, the feasibility of using transcranial MR-guided focused ultrasound to safely ablate substantial volumes of brain tumor tissue. PMID:25671132

  3. WE-A-18C-01: Emerging and Innovative Ultrasound Technology in Diagnosis and Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Emelianov, S; Oraevsky, A; Stafford, R

    The application of new ultrasound-based technologies in medicine has expanded in recent years. One area of rapid growth has been the combination of ultrasound with other methods of image generation and imaging modalities to produce hybrid approaches for diagnostic imaging and noninvasive therapeutic intervention. The presentations associated with this session will provide an overview of two emerging technologies that are currently being developed and implemented to enhance ultrasound-related diagnostic imaging and therapy: the utilization of optically-induced ultrasound imaging (optoacoustic / photoacoustic imaging) and the use of magnetic resonance imaging to guide the use of high-intensity focused ultrasound for therapeutic applications.more » Learning Objectives: Develop a general understanding of the underlying technologies associated with optoacoustic / photoacoustic tomography and MRguided high-intensity focused ultrasound. Develop an understanding of the current methods of these new ultrasound-based technologies in preclinical research and clinical applications.« less

  4. [Prognostic analysis of plantar fasciitis treated by pneumatic ballistic extracorporeal shock wave versus ultrasound guided intervention].

    PubMed

    Huo, Xiu-Lin; Wang, Ke-Tao; Zhang, Xiao-Ying; Yang, Yi-Tian; Cao, Fu-Yang; Yang, Jing; Yuan, Wei-Xiu; Mi, Wei-Dong

    2018-02-20

    To compare the medium- and long-term effect of pneumatic ballistic extracorporeal shock wave versus ultrasound-guided hormone injection in the treatment of plantar fasciitis. The clinical data were collected from patients with plantar fasciitis admitted to PLA General Hospital pain department from September, 2015 to February, 2017. The patients were randomly divided into ultrasound-guided drug injection group and shock wave group. The therapeutic parameters including the numerical rating scale (NRS) scores in the first step pain in the morning, American Orthopedic Foot and Ankle Society (AOFAS) Ankle Hindfoot Scale, and thickness of the plantar fascia were monitored before and at 1 week, 1 month, 3 months, and 6 months after the treatment. The recurrence rate, effectiveness, and patient satisfaction were compared between the two groups at 6 months after the treatment. Thirty-nine patients were enrolled in shock wave group and 38 patients in ultrasound group. The NRS scores in the first step pain in the morning were lowered after treatment in both groups (P<0.05), and the scores were significantly lower in ultrasound group than in shock wave group at 1 week and 1 month (P<0.01), but significantly higher in ultrasound group than in shock wave group at 3 and 6 months after treatment (P<0.05). The AOFAS functional scores were increased in both groups (P<0.05) at 6 months after treatment, was significantly lower in ultrasound group than in shock wave group than group B (90.44∓13.27 vs 75.76∓21.40; P<0.05). The effective rates in shock wave group and ultrasound group were 92.31% and 76.32%, respectively (P<0.05). Recurrence was found in 1 patient (2.56%) in shock wave group and in 8 (21.05%) in ultrasound group (P<0.05). The patient satisfaction scores were significantly higher in shock wave group than in ultrasound group (8.13∓2.67 vs 6.63∓3.75, P=0.048). Pneumatic ballistic extracorporeal shock achieves better medium- and long-term outcomes than ultrasound-guided hormone injection in the treatment of plantar fasciitis.

  5. MR-guided Focused Ultrasound for Uterine Fibroids

    MedlinePlus

    ... Professions Site Index A-Z MR-guided Focused Ultrasound for Uterine Fibroids Magnetic Resonance-guided Focused Ultrasound ( ... are the limitations of MRgFUS? What is Focused Ultrasound of Uterine Fibroids? Magnetic Resonance-guided Focused Ultrasound ( ...

  6. Image-guided tumor ablation: standardization of terminology and reporting criteria.

    PubMed

    Goldberg, S Nahum; Grassi, Clement J; Cardella, John F; Charboneau, J William; Dodd, Gerald D; Dupuy, Damian E; Gervais, Debra; Gillams, Alice R; Kane, Robert A; Lee, Fred T; Livraghi, Tito; McGahan, John; Phillips, David A; Rhim, Hyunchul; Silverman, Stuart G

    2005-06-01

    The field of interventional oncology with use of image-guided tumor ablation requires standardization of terminology and reporting criteria to facilitate effective communication of ideas and appropriate comparison between treatments that use different technologies, such as chemical (ethanol or acetic acid) ablation, and thermal therapies, such as radiofrequency, laser, microwave, ultrasound, and cryoablation. This document provides a framework that will hopefully facilitate the clearest communication between investigators and will provide the greatest flexibility in comparison between the many new, exciting, and emerging technologies. An appropriate vehicle for reporting the various aspects of image-guided ablation therapy, including classification of therapies and procedure terms, appropriate descriptors of imaging guidance, and terminology to define imaging and pathologic findings, are outlined. Methods for standardizing the reporting of follow-up findings and complications and other important aspects that require attention when reporting clinical results are addressed. It is the group's intention that adherence to the recommendations will facilitate achievement of the group's main objective: improved precision and communication in this field that lead to more accurate comparison of technologies and results and, ultimately, to improved patient outcomes. Copyright RSNA, 2005.

  7. Intravascular ultrasound for intracranial angioplasty and stent placement: technical case report.

    PubMed

    Wehman, J Christopher; Holmes, David R; Hanel, Ricardo A; Levy, Elad I; Hopkins, L Nelson

    2006-10-01

    Intravascular ultrasound (IVUS) imaging has been used extensively in coronary artery interventions and has provided invaluable information for the understanding and treatment of coronary arterial disease. We present here the first description, to our knowledge, of IVUS-guided intracranial arterial interventions in the clinical setting. Two patients underwent intracranial angioplasty and stent placement with the assistance of IVUS for the evaluation of their lesions. One patient underwent stenting to treat an occlusive dissection of the left internal carotid artery that occurred during arteriovenous malformation embolization. Another patient underwent angioplasty and stenting for high-grade restenosis of a basilar artery atherosclerotic lesion. Both patients underwent successful revascularization procedures. The patient with the dissection had a small intraventricular and parenchymal hemorrhage documented by computed tomography 4 hours after treatment, but did not develop hydrocephalus or further hemorrhage. Both patients did well clinically and had no permanent neurological deficits. IVUS provided important information in terms of lesion evaluation, stent selection, and stent placement in each case. IVUS of the intracranial circulation may assist the performance of intracranial angioplasty and stenting. It provides useful information that can affect clinical decisions. It may prove to be a valuable tool in clinical use and enhance our understanding of vascular disease of the intracranial circulation, as it has in the coronary circulation.

  8. Free-hand ultrasound guidance permits safe and efficient minimally invasive intrathymic injections in both young and aged mice.

    PubMed

    Tuckett, Andrea Z; Zakrzewski, Johannes L; Li, Duan; van den Brink, Marcel R M; Thornton, Raymond H

    2015-04-01

    The goal of this study was to evaluate whether use of an aseptic free-hand approach to ultrasound-guided injection facilitates injection into the thymic gland in mice. We used this interventional radiology technique in young, aged and immunodeficient mice and found that the thymus was visible in all cases. The mean injection period was 8 seconds in young mice and 19 seconds in aged or immunodeficient mice. Injection accuracy was confirmed by intrathymic location of an injected dye or by in vivo bioluminescence imaging of injected luciferase-expressing cells. Accurate intrathymic injection was confirmed in 97% of cases. No major complications were observed. We conclude that an aseptic freehand technique for ultrasound-guided intrathymic injection is safe and accurate and reduces the time required for intrathymic injections. This method facilitates large-scale experiments and injection of individual thymic lobes and is clinically relevant. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  9. Endoscopic ultrasound-guided transesophageal thoracentesis for minimal pleural effusion.

    PubMed

    Rana, Surinder Singh; Sharma, Ravi; Gupta, Rajesh

    2018-06-19

    Pleural effusion is a common finding both in patients with benign and malignant diseases of pleura and lung with diagnostic thoracentesis establishing the diagnosis in the majority of cases. The diagnostic thoracentesis can be done either blindly or under the guidance of ultrasound or computed tomography. However, minimal pleural effusion is difficult to sample even under image guidance. Endoscopic ultrasound (EUS) is known to detect smaller volume of pleural effusion and, thus, can help in guiding thoracentesis. To analyze the safety and efficacy of EUS-guided diagnostic thoracentesis in patients with undiagnosed minimal pleural effusion retrospectively. Retrospective analysis of the data of patients with minimal pleural effusion, who underwent EUS-guided transesophageal diagnostic thoracentesis over last 2 years, was performed. Thirteen patients (11 male; mean age 46.7 ± 16.2 years) with undiagnosed minimal pleural effusion underwent successful EUS-guided transesophageal diagnostic thoracentesis using a 22-G needle. Seven (53%) patients had fever on presentation whereas two presented with cough and loss of appetite. Eight to 54 mL fluid was aspirated with an attempt to completely empty the pleural cavity. There were no complications of the procedure. EUS-guided diagnostic thoracentesis is a safe and effective alternative for evaluating patients with minimal pleural effusion.

  10. Coded excitation ultrasonic needle tracking: An in vivo study.

    PubMed

    Xia, Wenfeng; Ginsberg, Yuval; West, Simeon J; Nikitichev, Daniil I; Ourselin, Sebastien; David, Anna L; Desjardins, Adrien E

    2016-07-01

    Accurate and efficient guidance of medical devices to procedural targets lies at the heart of interventional procedures. Ultrasound imaging is commonly used for device guidance, but determining the location of the device tip can be challenging. Various methods have been proposed to track medical devices during ultrasound-guided procedures, but widespread clinical adoption has remained elusive. With ultrasonic tracking, the location of a medical device is determined by ultrasonic communication between the ultrasound imaging probe and a transducer integrated into the medical device. The signal-to-noise ratio (SNR) of the transducer data is an important determinant of the depth in tissue at which tracking can be performed. In this paper, the authors present a new generation of ultrasonic tracking in which coded excitation is used to improve the SNR without spatial averaging. A fiber optic hydrophone was integrated into the cannula of a 20 gauge insertion needle. This transducer received transmissions from the ultrasound imaging probe, and the data were processed to obtain a tracking image of the needle tip. Excitation using Barker or Golay codes was performed to improve the SNR, and conventional bipolar excitation was performed for comparison. The performance of the coded excitation ultrasonic tracking system was evaluated in an in vivo ovine model with insertions to the brachial plexus and the uterine cavity. Coded excitation significantly increased the SNRs of the tracking images, as compared with bipolar excitation. During an insertion to the brachial plexus, the SNR was increased by factors of 3.5 for Barker coding and 7.1 for Golay coding. During insertions into the uterine cavity, these factors ranged from 2.9 to 4.2 for Barker coding and 5.4 to 8.5 for Golay coding. The maximum SNR was 670, which was obtained with Golay coding during needle withdrawal from the brachial plexus. Range sidelobe artifacts were observed in tracking images obtained with Barker coded excitation, and they were visually absent with Golay coded excitation. The spatial tracking accuracy was unaffected by coded excitation. Coded excitation is a viable method for improving the SNR in ultrasonic tracking without compromising spatial accuracy. This method provided SNR increases that are consistent with theoretical expectations, even in the presence of physiological motion. With the ultrasonic tracking system in this study, the SNR increases will have direct clinical implications in a broad range of interventional procedures by improving visibility of medical devices at large depths.

  11. Ultrasound-Guided Single-Injection Infraclavicular Block Versus Ultrasound-Guided Double-Injection Axillary Block: A Noninferiority Randomized Controlled Trial.

    PubMed

    Boivin, Ariane; Nadeau, Marie-Josée; Dion, Nicolas; Lévesque, Simon; Nicole, Pierre C; Turgeon, Alexis F

    2016-01-01

    Single-injection ultrasound-guided infraclavicular block is a simple, reliable, and effective technique. A simplified double-injection ultrasound-guided axillary block technique with a high success rate recently has been described. It has the advantage of being performed in a superficial and compressible location, with a potentially improved safety profile. However, its effectiveness in comparison with single-injection infraclavicular block has not been established. We hypothesized that the double-injection ultrasound-guided axillary block would show rates of complete sensory block at 30 minutes noninferior to the single-injection ultrasound-guided infraclavicular block. After approval by our research ethics committee and written informed consent, adults undergoing distal upper arm surgery were randomized to either group I, ultrasound-guided single-injection infraclavicular block, or group A, ultrasound-guided double-injection axillary block. In group I, 30 mL of 1.5% mepivacaine was injected posterior to the axillary artery. In group A, 25 mL of 1.5% mepivacaine was injected posteromedial to the axillary artery, after which 5 mL was injected around the musculocutaneous nerve. Primary outcome was the rate of complete sensory block at 30 minutes. Secondary outcomes were the onset of sensory and motor blocks, surgical success rates, performance times, and incidence of complications. All outcomes were assessed by a blinded investigator. The noninferiority of the double-injection ultrasound-guided axillary block was considered if the limits of the 90% confidence intervals (CIs) were within a 10% margin of the rate of complete sensory block of the infraclavicular block. At 30 minutes, the rate of complete sensory block was 79% in group A (90% CI, 71%-85%) compared with 91% in group I (90% CI, 85%-95%); the upper limit of CI of group A is thus included in the established noninferiority margin of 10%. The rate of complete sensory block was lower in group A (proportion difference of 12% [95% CI, 2-22]; P = 0.0091), as was surgical success rate (82% [95% CI, 74%-89%] vs 93% [95% CI, 86%-97%]; proportion difference of 11% [95% CI 1-20]; P = 0.0153). Sensory block onset also was slower in group A (log rank test P = 0.0020). Performance times were faster in group I (231 seconds [95% CI, 213-250]) than in group A (358 seconds [95% CI, 332-387]; P < 0.0001). No statistically significant difference was observed for vascular puncture, paresthesia during block performance, or procedure-related pain. No neurologic complication was noted at follow-up. We failed to demonstrate that the rate of complete sensory block of the double-injection axillary block is noninferior to the single-injection infraclavicular block. However, the rate of complete sensory block at 30 minutes is statistically significantly lower with the axillary block. The ultrasound-guided single-injection infraclavicular block thus seems to be the preferred technique over the axillary for upper arm anesthesia.

  12. Treatment of Partial Rotator Cuff Tear with Ultrasound-guided Platelet-rich Plasma

    PubMed Central

    Sengodan, Vetrivel Chezian; Kurian, Sajith; Ramasamy, Raghupathy

    2017-01-01

    Background: The treatment of symptomatic partial rotator cuff tear has presented substantial challenge to orthopaedic surgeons as it can vary from conservative to surgical repair. Researches have established the influence of platelet rich plasma in healing damaged tissue. Currently very few data are available regarding the evidence of clinical and radiological outcome of partial rotator cuff tear treated with ultrasound guided platelet rich plasma injection in English literature. Materials and Methods: 20 patients with symptomatic partial rotator cuff tears were treated with ultrasound guided platelet rich plasma injection. Before and after the injection of platelet rich plasma scoring was done with visual analogue score, Constant shoulder score, and UCLA shoulder score at 8 weeks and third month. A review ultrasound was performed 8 weeks after platelet rich plasma injection to assess the rotator cuff status. Results: Our study showed statistically significant improvements in 17 patients in VAS pain score, constant shoulder score and UCLA shoulder score. No significant changes in ROM were noted when matched to the contra-lateral side (P < 0.001) at the 3 month follow-up. The study also showed good healing on radiological evaluation with ultrasonogram 8 weeks after platelet rich plasma injection. Conclusion: Ultrasound guided platelet rich plasma injection for partial rotator cuff tears is an effective procedure that leads to significant decrease in pain, improvement in shoulder functions, much cost-effective and less problematic compared to a surgical treatment. PMID:28900553

  13. Real-time visualization of ultrasound-guided retrobulbar blockade: an imaging study.

    PubMed

    Luyet, C; Eichenberger, U; Moriggl, B; Remonda, L; Greif, R

    2008-12-01

    Retrobulbar anaesthesia allows eye surgery in awake patients. Severe complications of the blind techniques are reported. Ultrasound-guided needle introduction and direct visualization of the spread of local anaesthetic may improve quality and safety of retrobulbar anaesthesia. Therefore, we developed a new ultrasound-guided technique using human cadavers. In total, 20 blocks on both sides in 10 embalmed human cadavers were performed. Using a small curved array transducer and a long-axis approach, a 22 G short bevel needle was introduced under ultrasound guidance lateral and caudal of the eyeball until the needle tip was seen 2 mm away from the optic nerve. At this point, 2 ml of contrast dye as a substitute for local anaesthetic was injected. Immediately after the injection, the spread of the contrast dye was documented by means of CT scans performed in each cadaver. The CT scans showed the distribution of the contrast dye in the muscle cone and behind the posterior sclera in all but one case. No contrast dye was found inside the optic nerve or inside the eyeball. In one case, there could be an additional trace of contrast dye behind the orbita. Our new ultrasound-guided technique has the potential to improve safety and efficacy of the procedure by direct visualization of the needle placement and the distribution of the injected fluid. Furthermore, the precise injection near the optic nerve could lead to a reduction of the amount of the local anaesthetic needed with fewer related complications.

  14. Lower Extremity Injury Patterns in Elite Ballet Dancers: Ultrasound/MRI Imaging Features and an Institutional Overview of Therapeutic Ultrasound Guided Percutaneous Interventions.

    PubMed

    Rehmani, Razia; Endo, Yoshimi; Bauman, Phillip; Hamilton, William; Potter, Hollis; Adler, Ronald

    2015-10-01

    Altered biomechanics from repetitive microtrauma, such as long practice hours in en pointe (tip of the toes) or demi pointe (balls of the feet) predispose ballet dancers to a multitude of musculoskeletal pathologies particularly in the lower extremities. Both ultrasound and magnetic resonance imaging (MRI) are radiation-sparing modalities which can be used to confidently evaluate these injuries, with ultrasound (US) offering the added utility of therapeutic intervention at the same time in experienced hands. The purposes of this paper were: (1) to illustrate the US and MRI features of lower extremity injury patterns in ballet dancers, focusing on pathologies commonly encountered at a single orthopedic hospital; (2) to present complementary roles of both ultrasound and MRI in the evaluation of these injuries whenever possible; (3) to review and present our institutional approach towards therapeutic ultrasound-guided interventions by presenting explicit cases. Online searches were performed using the search criteria of "ballet biomechanics" and "ballet injuries." The results were then further narrowed down by limiting articles published in the past 15 years, modality (US and MRI), anatomical region (foot and ankle, hip and knee) and to major radiology, orthopedics, and sports medicine journals. Performing ballet poses major stress to lower extremities and predisposes dancer to several musculoskeletal injuries. These can be adequately evaluated by both US and MRI. US is useful for evaluating superficial structures such as soft tissues, tendons, and ligaments, particularly in the foot and ankle. MRI provides superior resolution of deeper structures such as joints, bone marrow, and cartilage. In addition, US can be used as a therapeutic tool for providing quick symptomatic improvement in these athletes for who "time is money". Performing ballet may cause major stress to the lower extremities, predominantly affecting the foot and ankle, followed by the knee and hip. US and MRI play complementary roles in evaluating various orthopedic conditions in ballet dancers, with US allowing for dynamic evaluation and guidance for interventions.

  15. Magnetic Resonance-Guided High-Intensity Focused Ultrasound (MR-HIFU) in Treatment of Symptomatic Uterine Myomas

    PubMed Central

    Filipowska, Justyna; Łoziński, Tomasz

    2014-01-01

    Summary Magnetic Resonance-guided High-Intensity Focused Ultrasound (MR-HIFU) is a noninvasive technique for ablation therapy for uterine myomas, where focused ultrasound energy beam generates localized high temperature in the selected area and coagulates chosen tissue, leaving the skin and tissues in between unharmed. Magnetic resonance imaging enables accurate targeting for HIFU as well as temperature monitoring during treatment. MR guidance with 3D anatomical imaging provides reference data for treatment planning, while real-time temperature monitoring aids in controlling ablation process. This review provides basic information regarding methodology, clinical indications for this kind of treatment, expected outcome and patient management during MR-HIFU procedure. The aim of this work is to introduce a new, noninvasive treatment method for uterine leiomyomas and to present a comparison with other currently used methods. PMID:25469176

  16. Magnetic Resonance-Guided High-Intensity Focused Ultrasound (MR-HIFU) in Treatment of Symptomatic Uterine Myomas.

    PubMed

    Filipowska, Justyna; Loziński, Tomasz

    2014-01-01

    Magnetic Resonance-guided High-Intensity Focused Ultrasound (MR-HIFU) is a noninvasive technique for ablation therapy for uterine myomas, where focused ultrasound energy beam generates localized high temperature in the selected area and coagulates chosen tissue, leaving the skin and tissues in between unharmed. Magnetic resonance imaging enables accurate targeting for HIFU as well as temperature monitoring during treatment. MR guidance with 3D anatomical imaging provides reference data for treatment planning, while real-time temperature monitoring aids in controlling ablation process. This review provides basic information regarding methodology, clinical indications for this kind of treatment, expected outcome and patient management during MR-HIFU procedure. The aim of this work is to introduce a new, noninvasive treatment method for uterine leiomyomas and to present a comparison with other currently used methods.

  17. Implementing Endobronchial Ultrasound-Guided (EBUS) for Staging and Diagnosis of Lung Cancer: A Cost Analysis

    PubMed Central

    Slavova-Azmanova, Neli S.; Phillips, Martin; Trevenen, Michelle L.; Li, Ian W.; Johnson, Claire E.

    2018-01-01

    Background Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) and guide sheath (EBUS-GS) are gaining popularity for diagnosis and staging of lung cancer compared to CT-guided transthoracic needle aspiration (CT-TTNA), blind fiber-optic bronchoscopy, and mediastinoscopy. This paper aimed to examine predictors of higher costs for diagnosing and staging lung cancer, and to assess the effect of EBUS techniques on hospital cost. Material/Methods Hospital costs for diagnosis and staging of new primary lung cancer patients presenting in 2007–2008 and 2010–2011 were reviewed retrospectively. Multiple linear regression was used to determine relationships with hospital cost. Results We reviewed 560 lung cancer patient records; 100 EBUS procedures were performed on 90 patients. Higher hospital costs were associated with: EBUS-TBNA performed (p<0.0001); increasing inpatient length of stay (p<0.0001); increasing number of other surgical/diagnostic procedures (p<0.0001); whether the date of management decision fell within an inpatient visit (p<0.0001); and if the patient did not have a CT-TTNA, then costs increased as the number of imaging events increased (interaction p<0.0001). Cohort was not significantly related to cost. Location of the procedure (outside vs. inside theater) was a predictor of lower one-day EBUS costs (p<0.0001). Cost modelling revealed potential cost saving of $1506 per EBUS patient if all EBUS procedures were performed outside rather than in the theater ($66,259 per annum). Conclusions EBUS-TBNA only was an independent predictor of higher cost for diagnosis and staging of lung cancer. Performing EBUS outside compared to in the theater may lower costs for one-day procedures; potential future savings are considerable if more EBUS procedures could be performed outside the operating theater. PMID:29377878

  18. Intravascular ultrasound-guided unprotected left main coronary artery stenting in the elderly.

    PubMed

    Tan, Qiang; Wang, Qingsheng; Liu, Dongtian; Zhang, Shuangyue; Zhang, Yang; Li, Yang

    2015-05-01

    To investigate whether intravascular ultrasound (IVUS) guided percutaneous coronary intervention (PCI) could improve clinical outcomes compared with angiography-guided PCI in the treatment of unprotected left main coronary artery stenosis (ULMCA) in the elderly. This controlled study was carried out between October 2009 and September 2012, in Qinhuangdao First Hospital, Hebei Province, China. One hundred and twenty-three consecutive patients with ULMCA, aged 70 or older, were randomized to an IVUS-guided group and a control group. The occurrence of major adverse cardiac events (MACE): death, non-fatal myocardial infarction, or target lesion revascularizations) were recorded after 2 years of follow-up. The IVUS-guided group had a lower rate of 2-year MACE than the control group (13.1% versus 29.3%, p=0.031). The incidence of target lesion revascularization was lower in the IVUS-guided group than in the control group (9.1% versus 24%, p=0.045). However, there were no differences in death and myocardial infarction in the 2 groups. On Cox proportional hazard analysis, distal lesion was the independent predictor of MACE (hazard ratio [HR]: 1.99, confidence interval [CI]: 1.129-2.367; p=0.043); IVUS guidance was independent factor of survival free of MACE (HR: 0.414, CI: 0.129-0.867; p=0.033). The use of IVUS could reduce MACE in elderly patients undergoing ULMCA intervention.

  19. Factors influencing discomfort during anterior ultrasound-guided injection for hip arthrography.

    PubMed

    Hsu, Yi-Chih; Wu, Yu-Cheng; Kao, Hao-Lun; Pan, Ru-Yu; Lee, Meei-Shyuan; Huang, Guo-Shu

    2013-09-01

    Although ultrasound (US)-guided injection techniques for magnetic resonance arthrography of the hip have been used with increasing frequency to diagnose internal joint derangements, little is known about patient tolerance, which is relevant information for patients. The objective of this study was to evaluate prospectively the association between possible influencing factors and discomfort felt during the performance of anterior US-guided injection techniques targeting the femoral head-neck junction during hip arthrography. Forty-four consecutive patients (21 women and 23 men; mean age, 41 years) undergoing magnetic resonance hip arthrography were sequentially assigned to receive injection alternating between fixed and freehand US-guided injection. Discomfort was assessed using a visual analog scale and relative ratings. Patient body mass index, extra-articular contrast leakage, the duration of the procedure, the needle advancement distance, and the fixed trajectory of the needle were assessed. Pearson's correlation coefficients and multiple logistic regression analysis were used to determine the association. Puncture was successfully accomplished in all cases, and no relevant complications were reported. The only significant relationships were between discomfort and the time required for needle manipulation (r = 0.8) and fixed US-guided injection (r = 0.6; p < 0.001). Compared with the freehand technique, the fixed technique resulted in significantly less pain and took significantly less time to perform (p < 0.001). The procedure time during needle manipulation in the fixed US-guided injections (4.0 ± 0.9 seconds) was significantly less than that in the freehand US-guided injections (19.4 ± 17.6 seconds; p < 0.001). No significant relationships were found between discomfort and other parameters (r < 0.3, p > 0.05). The procedure time appears to be the most important factor influencing patient discomfort. Fixed US-guided injection is a time-saving technique that alleviates procedure-related discomfort. Copyright © 2013. Published by Elsevier B.V.

  20. Laparoscopic Ultrasound-Guided Radiofrequency Ablation of Uterine Fibroids

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Milic, Andrea; Asch, Murray R.; Hawrylyshyn, Peter A.

    Four patients with symptomatic uterine fibroids measuring less than 6 cm underwent laparoscopic ultrasound-guided radiofrequency ablation (RFA) using multiprobe-array electrodes. Follow-up of the treated fibroids was performed with gadolinium-enhanced magnetic resonance imaging (MRI) and patients' symptoms were assessed by telephone interviews. The procedure was initially technically successful in 3 of the 4 patients and MRI studies at 1 month demonstrated complete fibroid ablation. Symptom improvement, including a decrease in menstrual bleeding and pain, was achieved in 2 patients at 3 months. At 7 months, 1 of these 2 patients experienced symptom worsening which correlated with recurrent fibroid on MRI. Themore » third, initially technically successfully treated patient did not experience any symptom relief after the procedure and was ultimately diagnosed with adenomyosis. Our preliminary results suggest that RFA is a technically feasible treatment for symptomatic uterine fibroids in appropriately selected patients.« less

  1. Portable ultrasound in disaster triage: a focused review.

    PubMed

    Wydo, S M; Seamon, M J; Melanson, S W; Thomas, P; Bahner, D P; Stawicki, S P

    2016-04-01

    Ultrasound technology has become ubiquitous in modern medicine. Its applications span the assessment of life-threatening trauma or hemodynamic conditions, to elective procedures such as image-guided peripheral nerve blocks. Sonographers have utilized ultrasound techniques in the pre-hospital setting, emergency departments, operating rooms, intensive care units, outpatient clinics, as well as during mass casualty and disaster management. Currently available ultrasound devices are more affordable, portable, and feature user-friendly interfaces, making them well suited for use in the demanding situation of a mass casualty incident (MCI) or disaster triage. We have reviewed the existing literature regarding the application of sonology in MCI and disaster scenarios, focusing on the most promising and practical ultrasound-based paradigms applicable in these settings.

  2. Ethnicity influences pain after ultrasound-guided percutaneous liver biopsy.

    PubMed

    Mahadeva, Sanjiv; Mahfudz, Anis S; Vijayananthan, Anushya

    2015-12-01

    The influence of ethnicity on pain complicating ultrasound-guided percutaneous liver biopsy (US-guided PLB) and its clinical impact has not been reported to date. Consecutive adults from a multiethnic background, undergoing an US-guided PLB, were independently assessed for pain up to 6 h after the procedure. Clinical and demographic parameters were analysed to determine independent predictors of significant pain after PLB. Willingness to undergo a repeat procedure was assessed 1 week after PLB. Data from 203 patients (median age 50 years; 43.9% female; ethnicity: Malay 41.5%, Chinese 40%, Indian 18%; median BMI 27.7 kg/m; median waist circumference 92.0 cm) were analysed. Pain after US-guided PLB was experienced in 133 (61.1%) patients, with severity grades as follows: none, n=81 (39.9%); mild, n=56 (27.6%); moderate, n=51 (25.1%); and severe, n=15 (7.4%). Analgesia requirements correlated well with severity of pain. Independent predictors of significant pain after PLB (moderate and severe categories) in patients included age less than 50 years [odds ratio (OR) 3.0], female sex (OR 3.7), Indian ethnicity (OR 2.9) and Malay ethnicity (OR 2.7), but not number of needle passes, BMI and educational levels. Patients who experienced moderate/severe pain were less willing to undergo a repeat PLB compared with those who experienced mild/no pain (60.9 vs. 82.8%, P=0.001). Ethnicity has an important role in the development of pain after US-guided PLB. This has a significant impact on willingness to repeat the procedure.

  3. Magnetic resonance imaging-guided focused ultrasound treatment of symptomatic uterine fibroids: impact of technology advancement on ablation volumes in 115 patients.

    PubMed

    Trumm, Christoph G; Stahl, Robert; Clevert, Dirk-André; Herzog, Peter; Mindjuk, Irene; Kornprobst, Sabine; Schwarz, Christina; Hoffmann, Ralf-Thorsten; Reiser, Maximilian F; Matzko, Matthias

    2013-06-01

    The aim of this study was to assess the impact of the advanced technology of the new ExAblate 2100 system (Insightec Ltd, Haifa, Israel) for magnetic resonance imaging (MRI)-guided focused ultrasound surgery on treatment outcomes in patients with symptomatic uterine fibroids, as measured by the nonperfused volume ratio. This is a retrospective analysis of 115 women (mean age, 42 years; range, 27-54 years) with symptomatic fibroids who consecutively underwent MRI-guided focused ultrasound treatment in a single center with the new generation ExAblate 2100 system from November 2010 to June 2011. Mean ± SD total volume and number of treated fibroids (per patient) were 89 ± 94 cm and 2.2 ± 1.7, respectively. Patient baseline characteristics were analyzed regarding their impact on the resulting nonperfused volume ratio. Magnetic resonance imaging-guided focused ultrasound treatment was technically successful in 115 of 123 patients (93.5%). In 8 patients, treatment was not possible because of bowel loops in the beam pathway that could not be mitigated (n = 6), patient movement (n = 1), and system malfunction (n = 1). Mean nonperfused volume ratio was 88% ± 15% (range, 38%-100%). Mean applied energy level was 5400 ± 1200 J, and mean number of sonications was 74 ± 27. No major complications occurred. Two cases of first-degree skin burn resolved within 1 week after the intervention. Of the baseline characteristics analyzed, only the planned treatment volume had a statistically significant impact on nonperfused volume ratio. With technological advancement, the outcome of MRI-guided focused ultrasound treatment in terms of the nonperfused volume ratio can be enhanced with a high safety profile, markedly exceeding results reported in previous clinical trials.

  4. 76 FR 38404 - Center for Scientific Review; Notice of Closed Meetings

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-30

    ...; Shared Instrumentation: Grant Program Ultrasound Imaging S10. Date: July 19, 2011. Time: 1 p.m. to 5 p.m... Trials for Imaging and Image-Guided Interventions; Exploratory Grants. Date: July 14, 2011. Time: 1 p.m...

  5. Guidance and examination by ultrasound versus landmark and radiographic method for placement of subclavian central venous catheters: study protocol for a randomized controlled trial

    PubMed Central

    2014-01-01

    Background Central venous catheters play an important role in patient care. Real-time ultrasound-guided subclavian central venous (SCV) cannulation may reduce the incidence of complications and the time between skin penetration and the aspiration of venous blood into the syringe. Ultrasonic diagnosis of catheter misplacement and pneumothorax related to central venous catheterization is rapid and accurate. It is unclear, however, whether ultrasound real-time guidance and examination can reduce procedure times and complication rates when compared with landmark guidance and radiographic examination for SCV catheterization. Methods/Design The Subclavian Central Venous Catheters Guidance and Examination by UltraSound (SUBGEUS) study is an investigator-initiated single center, randomized, controlled two-arm trial. Three hundred patients undergoing SCV catheter placement will be randomized to ultrasound real-time guidance and examination or landmark guidance and radiographic examination. The primary outcome is the time between the beginning of the procedure and control of the catheter. Secondary outcomes include the times required for the six components of the total procedure, the occurrence of complications (pneumothorax, hemothorax, or misplacement), failure of the technique and occurrence of central venous catheter infections. Discussion The SUBGEUS trial is the first randomized controlled study to investigate whether ultrasound real-time guidance and examination for SCV catheter placement reduces all procedure times and the rate of complications. Trial registration ClinicalTrials.gov Identifier: NCT01888094 PMID:24885789

  6. [Ultrasound guided percutaneous nephrolithotripsy].

    PubMed

    Guliev, B G

    2014-01-01

    The study was aimed to the evaluation of the effectiveness and results of ultrasound guided percutaneous nephrolithotripsy (PNL) for the treatment of patients with large stones in renal pelvis. The results of PNL in 138 patients who underwent surgery for kidney stones from 2011 to 2013 were analyzed. Seventy patients (Group 1) underwent surgery with combined ultrasound and radiological guidance, and 68 patients (Group 2)--only with ultrasound guidance. The study included patients with large renal pelvic stones larger than 2.2 cm, requiring the formation of a single laparoscopic approach. Using the comparative analysis, the timing of surgery, the number of intra- and postoperative complications, blood loss and length of stay were evaluated. Percutaneous access was successfully performed in all patients. Postoperative complications (exacerbation of chronic pyelonephritis, gross hematuria) were observed in 14.3% of patients in Group 1 and in 14.7% of patients in Group 2. Bleeding requiring blood transfusion, and injuries of adjacent organs were not registered. Efficacy of PNL in the Group 1 was 95.7%; 3 (4.3%) patients required additional interventions. In Group 2, the effectiveness of PNL was 94.1%, 4 (5.9%) patients additionally underwent extracorporeal lithotripsy. There were no significant differences in the effectiveness of PNL, the volume of blood loss and duration of hospitalization. Ultrasound guided PNL can be performed in large pelvic stones and sufficient expansion of renal cavities, thus reducing radiation exposure of patients and medical staff.

  7. Fusion imaging of contrast-enhanced ultrasound and contrast-enhanced CT or MRI before radiofrequency ablation for liver cancers.

    PubMed

    Bo, Xiao-Wan; Xu, Hui-Xiong; Wang, Dan; Guo, Le-Hang; Sun, Li-Ping; Li, Xiao-Long; Zhao, Chong-Ke; He, Ya-Ping; Liu, Bo-Ji; Li, Dan-Dan; Zhang, Kun

    2016-11-01

    To investigate the usefulness of fusion imaging of contrast-enhanced ultrasound (CEUS) and CECT/CEMRI before percutaneous ultrasound-guided radiofrequency ablation (RFA) for liver cancers. 45 consecutive patients with 70 liver lesions were included between March 2013 and October 2015, and all the lesions were identified on CEMRI/CECT prior to inclusion in the study. Planning ultrasound for percutaneous RFA was performed using conventional ultrasound, ultrasound-CECT/CEMRI and CEUS and CECT/CEMRI fusion imaging during the same session. The numbers of the conspicuous lesions on ultrasound and fusion imaging were recorded. RFA was performed according to the results of fusion imaging. Complete response (CR) rate was calculated and the complications were recorded. On conventional ultrasound, 25 (35.7%) of the 70 lesions were conspicuous, whereas 45 (64.3%) were inconspicuous. Ultrasound-CECT/CEMRI fusion imaging detected additional 24 lesions thus increased the number of the conspicuous lesions to 49 (70.0%) (70.0% vs 35.7%; p < 0.001 in comparison with conventional ultrasound). With the use of CEUS and CECT/CEMRI fusion imaging, the number of the conspicuous lesions further increased to 67 (95.7%, 67/70) (95.7% vs 70.0%, 95.7% vs 35.7%; both p < 0.001 in comparison with ultrasound and ultrasound-CECT/CEMRI fusion imaging, respectively). With the assistance of CEUS and CECT/CEMRI fusion imaging, the confidence level of the operator for performing RFA improved significantly with regard to visualization of the target lesions (p = 0.001). The CR rate for RFA was 97.0% (64/66) in accordance to the CECT/CEMRI results 1 month later. No procedure-related deaths and major complications occurred during and after RFA. Fusion of CEUS and CECT/CEMRI improves the visualization of those inconspicuous lesions on conventional ultrasound. It also facilitates improvement in the RFA operators' confidence and CR of RFA. Advances in knowledge: CEUS and CECT/CEMRI fusion imaging is better than both conventional ultrasound and ultrasound-CECT/CEMRI fusion imaging for lesion visualization and improves the operator confidence, thus it should be recommended to be used as a routine in ultrasound-guided percutaneous RFA procedures for liver cancer.

  8. Fusion imaging of contrast-enhanced ultrasound and contrast-enhanced CT or MRI before radiofrequency ablation for liver cancers

    PubMed Central

    Bo, Xiao-Wan; Wang, Dan; Guo, Le-Hang; Sun, Li-Ping; Li, Xiao-Long; Zhao, Chong-Ke; He, Ya-Ping; Liu, Bo-Ji; Li, Dan-Dan; Zhang, Kun

    2016-01-01

    Objective: To investigate the usefulness of fusion imaging of contrast-enhanced ultrasound (CEUS) and CECT/CEMRI before percutaneous ultrasound-guided radiofrequency ablation (RFA) for liver cancers. Methods: 45 consecutive patients with 70 liver lesions were included between March 2013 and October 2015, and all the lesions were identified on CEMRI/CECT prior to inclusion in the study. Planning ultrasound for percutaneous RFA was performed using conventional ultrasound, ultrasound-CECT/CEMRI and CEUS and CECT/CEMRI fusion imaging during the same session. The numbers of the conspicuous lesions on ultrasound and fusion imaging were recorded. RFA was performed according to the results of fusion imaging. Complete response (CR) rate was calculated and the complications were recorded. Results: On conventional ultrasound, 25 (35.7%) of the 70 lesions were conspicuous, whereas 45 (64.3%) were inconspicuous. Ultrasound-CECT/CEMRI fusion imaging detected additional 24 lesions thus increased the number of the conspicuous lesions to 49 (70.0%) (70.0% vs 35.7%; p < 0.001 in comparison with conventional ultrasound). With the use of CEUS and CECT/CEMRI fusion imaging, the number of the conspicuous lesions further increased to 67 (95.7%, 67/70) (95.7% vs 70.0%, 95.7% vs 35.7%; both p < 0.001 in comparison with ultrasound and ultrasound-CECT/CEMRI fusion imaging, respectively). With the assistance of CEUS and CECT/CEMRI fusion imaging, the confidence level of the operator for performing RFA improved significantly with regard to visualization of the target lesions (p = 0.001). The CR rate for RFA was 97.0% (64/66) in accordance to the CECT/CEMRI results 1 month later. No procedure-related deaths and major complications occurred during and after RFA. Conclusion: Fusion of CEUS and CECT/CEMRI improves the visualization of those inconspicuous lesions on conventional ultrasound. It also facilitates improvement in the RFA operators' confidence and CR of RFA. Advances in knowledge: CEUS and CECT/CEMRI fusion imaging is better than both conventional ultrasound and ultrasound-CECT/CEMRI fusion imaging for lesion visualization and improves the operator confidence, thus it should be recommended to be used as a routine in ultrasound-guided percutaneous RFA procedures for liver cancer. PMID:27626506

  9. Echogenicity based approach to detect, segment and track the common carotid artery in 2D ultrasound images.

    PubMed

    Narayan, Nikhil S; Marziliano, Pina

    2015-08-01

    Automatic detection and segmentation of the common carotid artery in transverse ultrasound (US) images of the thyroid gland play a vital role in the success of US guided intervention procedures. We propose in this paper a novel method to accurately detect, segment and track the carotid in 2D and 2D+t US images of the thyroid gland using concepts based on tissue echogenicity and ultrasound image formation. We first segment the hypoechoic anatomical regions of interest using local phase and energy in the input image. We then make use of a Hessian based blob like analysis to detect the carotid within the segmented hypoechoic regions. The carotid artery is segmented by making use of least squares ellipse fit for the edge points around the detected carotid candidate. Experiments performed on a multivendor dataset of 41 images show that the proposed algorithm can segment the carotid artery with high sensitivity (99.6 ±m 0.2%) and specificity (92.9 ±m 0.1%). Further experiments on a public database containing 971 images of the carotid artery showed that the proposed algorithm can achieve a detection accuracy of 95.2% with a 2% increase in performance when compared to the state-of-the-art method.

  10. Free-hand ultrasound guidance permits safe and efficient minimally invasive intrathymic injections in both young and aged mice

    PubMed Central

    Tuckett, Andrea Z.; Zakrzewski, Johannes L.; Li, Duan; van den Brink, Marcel R.M.; Thornton, Raymond H.

    2014-01-01

    The goal of this study was to evaluate whether using an aseptic free-hand approach for ultrasound-guided injection facilitates injection into the thymic gland in mice. We used this interventional radiology technique in young, aged, and immunodeficient mice and found that the thymus was visible in all cases. The mean injection period was 8 s in young mice and 19 s in aged or immunodeficient mice. Injection accuracy was confirmed by intrathymic location of an injected dye, or by in vivo bioluminescence imaging of injected luciferase-expressing cells. Accurate intrathymic injection was confirmed in 97% of cases. No major complications were observed. We conclude that an aseptic free-hand technique for ultrasound-guided intrathymic injection is safe, accurate, and reduces the time required for intrathymic injections. This method facilitates large-scale experiments, injection of individual thymic lobes, and is clinically relevant. PMID:25701534

  11. Autonomic responses to ultrasound-guided percutaneous needle electrolysis of the patellar tendon in healthy male footballers.

    PubMed

    de la Cruz Torres, Blanca; Albornoz Cabello, Manuel; García Bermejo, Paula; Naranjo Orellana, José

    2016-08-01

    Ultrasound (US)-guided percutaneous needle electrolysis (PNE) is a novel minimally invasive approach, which involves the application of a galvanic current via an acupuncture needle. As in any procedure involving needling, vagal reactions have been reported during PNE. To examine for changes in autonomic activity during the US-guided PNE technique on healthy patellar tendons by measurement and analysis of heart rate variability (HRV). Twenty-two male footballers were randomly allocated to: a control group (11 players), for whom HRV was recorded for 10 min, both at rest and during an exhaustive US examination of the patellar tendon and adjacent structures; and an experimental group (11 players), for whom HRV was recorded for 10 min, both at rest and during application of US-guided PNE on the patellar tendon. The following HRV parameters were assessed: mean NN interval, mean heart rate, time domain parameters (SDNN, rMSSD, pNN50), diameters of the Poincaré plot (SD1, SD2), stress score, and sympathetic/parasympathetic ratio. There were no differences between groups in any baseline measurements, nor were there any significant differences between control group measurements (baseline vs intervention). The experimental group exhibited statistically significant increases in SDNN/SD1 (p=0.02/p=0.03) and SD2 (p=0.03), indicating increased parasympathetic and decreased sympathetic activity, respectively. US-guided PNE was associated with an autonomic imbalance characterised by greater parasympathetic activity, which could potentially result in a vasovagal reaction. Care should be taken to monitor for adverse reactions during US-guided PNE and simple HRV indicators may have a role in early detection. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  12. Evaluation of the clinical benefit of an electromagnetic navigation system for CT-guided interventional radiology procedures in the thoraco-abdominal region compared with conventional CT guidance (CTNAV II): study protocol for a randomised controlled trial.

    PubMed

    Rouchy, R C; Moreau-Gaudry, A; Chipon, E; Aubry, S; Pazart, L; Lapuyade, B; Durand, M; Hajjam, M; Pottier, S; Renard, B; Logier, R; Orry, X; Cherifi, A; Quehen, E; Kervio, G; Favelle, O; Patat, F; De Kerviler, E; Hughes, C; Medici, M; Ghelfi, J; Mounier, A; Bricault, I

    2017-07-06

    Interventional radiology includes a range of minimally invasive image-guided diagnostic and therapeutic procedures that have become routine clinical practice. Each procedure involves a percutaneous needle insertion, often guided using computed tomography (CT) because of its availability and usability. However, procedures remain complicated, in particular when an obstacle must be avoided, meaning that an oblique trajectory is required. Navigation systems track the operator's instruments, meaning the position and progression of the instruments are visualised in real time on the patient's images. A novel electromagnetic navigation system for CT-guided interventional procedures (IMACTIS-CT®) has been developed, and a previous clinical trial demonstrated improved needle placement accuracy in navigation-assisted procedures. In the present trial, we are evaluating the clinical benefit of the navigation system during the needle insertion step of CT-guided procedures in the thoraco-abdominal region. This study is designed as an open, multicentre, prospective, randomised, controlled interventional clinical trial and is structured as a standard two-arm, parallel-design, individually randomised trial. A maximum of 500 patients will be enrolled. In the experimental arm (navigation system), the procedures are carried out using navigation assistance, and in the active comparator arm (CT), the procedures are carried out with conventional CT guidance. The randomisation is stratified by centre and by the expected difficulty of the procedure. The primary outcome of the trial is a combined criterion to assess the safety (number of serious adverse events), efficacy (number of targets reached) and performance (number of control scans acquired) of navigation-assisted, CT-guided procedures as evaluated by a blinded radiologist and confirmed by an expert committee in case of discordance. The secondary outcomes are (1) the duration of the procedure, (2) the satisfaction of the operator and (3) the irradiation dose delivered, with (4) subgroup analysis according to the expected difficulty of the procedure, as well as an evaluation of (5) the usability of the device. This trial addresses the lack of published high-level evidence studies in which navigation-assisted CT-guided interventional procedures are evaluated. This trial is important because it addresses the problems associated with conventional CT guidance and is particularly relevant because the number of interventional radiology procedures carried out in routine clinical practice is increasing. ClinicalTrials.gov identifier: NCT01896219 . Registered on 5 July 2013.

  13. An all-optical fiber optic photoacoustic transducer

    NASA Astrophysics Data System (ADS)

    Thathachary, Supriya V.; Motameni, Cameron; Ashkenazi, Shai

    2018-02-01

    A highly sensitive fiber-optic Fabry-Perot photoacoustic transducer is proposed in this work. The transducer will consist of separate transmit and receive fibers. The receiver will be composed of a Fabry-Perot Ultrasound sensor with a selfwritten waveguide with all-optical ultrasound detection with high sensitivity. In previous work, we have shown an increase in resonator Q-factor from 1900 to 3200 for a simulated Fabry-Perot ultrasound detector of 45 μm thickness upon including a waveguide to limit lateral power losses. Subsequently, we demonstrated a prototype device with 30nm gold mirrors and a cavity composed of the photosensitive polymer Benzocyclobutene. This 80 µm thick device showed an improvement in its Q-factor from 2500 to 5200 after a selfaligned waveguide was written into the cavity using UV exposure. Current work uses a significantly faster fabrication technique using a combination of UV-cured epoxies for the cavity medium, and the waveguide within it. This reduces the fabrication time from several hours to a few minutes, and significantly lowers the cost of fabrication. We use a dip-coating technique to deposit the polymer layer. Future work will include the use of Dielectric Bragg mirrors in place of gold to achieve better reflectivity, thereby further improving the Q-factor of the device. The complete transducer presents an ideal solution for intravascular imaging in cases where tissue differentiation is desirable, an important feature in interventional procedures where arterial perforation is a risk. The final design proposed comprises the transducer within a guidewire to guide interventions for Chronic Total Occlusions, a disease state for which there are currently no invasive imaging options.

  14. Ultrasound: from Earth to space.

    PubMed

    Law, Jennifer; Macbeth, Paul B

    2011-06-01

    Ultrasonography is a versatile imaging modality that offers many advantages over radiography, computed tomography, and magnetic resonance imaging. On Earth, the use of ultrasound has become standard in many areas of medicine including diagnosis of medical and surgical diseases, management of obstetric and gynecologic conditions, assessment of critically ill patients, and procedural guidance. Advances in telecommunications have enabled remotely-guided ultrasonography for both geographically isolated populations and astronauts aboard the International Space Station. While ultrasound has traditionally been used in spaceflight to study anatomical and physiological adaptations to microgravity and evaluate countermeasures, recent years have seen a growth of applications adapted from terrestrial techniques. Terrestrial, remote, and space applications for ultrasound are reviewed in this paper.

  15. Ultrasound: From Earth to Space

    PubMed Central

    Law, Jennifer; Macbeth, Paul. B.

    2011-01-01

    Ultrasonography is a versatile imaging modality that offers many advantages over radiography, computed tomography, and magnetic resonance imaging. On Earth, the use of ultrasound has become standard in many areas of medicine including diagnosis of medical and surgical diseases, management of obstetric and gynecologic conditions, assessment of critically ill patients, and procedural guidance. Advances in telecommunications have enabled remotely-guided ultrasonography for both geographically isolated populations and astronauts aboard the International Space Station. While ultrasound has traditionally been used in spaceflight to study anatomical and physiological adaptations to microgravity and evaluate countermeasures, recent years have seen a growth of applications adapted from terrestrial techniques. Terrestrial, remote, and space applications for ultrasound are reviewed in this paper. PMID:22399873

  16. Full-length silicone insoles versus ultrasound-guided corticosteroid injection in the management of plantar fasciitis: a randomized clinical trial.

    PubMed

    Yucel, Ufuk; Kucuksen, Sami; Cingoz, Havva T; Anliacik, Emel; Ozbek, Orhan; Salli, Ali; Ugurlu, Hatice

    2013-12-01

    Plantar fasciitis often leads to disability. Optimal treatment for this clinical condition is still unknown. To compare the effectiveness of wearing a full-length silicone insole with ultrasound-guided corticosteroid injection in the management of plantar fasciitis. Randomized clinical trial. Forty-two patients with chronic unilateral plantar fasciitis were allocated randomly to have an ultrasound-guided corticosteroid injection or wear a full-length silicone insole. Data were collected before the procedure and 1 month after. The primary outcome measures included first-step heel pain via Visual Analogue Scale and Heel Tenderness Index. Other outcome measures were the Foot and Ankle Outcome Score and ultrasonographic thickness of the plantar fascia. After 1 month, a significant improvement was shown in Visual Analogue Scale, Heel Tenderness Index, Foot and Ankle Outcome Score, and ultrasonographic thickness of plantar fascia in both groups. Visual Analogue Scale scores, Foot and Ankle Outcome Score pain, Foot and Ankle Outcome Score for activities of daily living, Foot and Ankle Outcome Score for sport and recreation function, and plantar fascia thickness were better in injection group than in insole group (p < 0.05). Although both ultrasound-guided corticosteroid injection and wearing a full-length silicone insole were effective in the conservative treatment of plantar fasciitis, we recommend the use of silicone insoles as a first line of treatment for persons with plantar fasciitis.

  17. Navigational Guidance and Ablation Planning Tools for Interventional Radiology.

    PubMed

    Sánchez, Yadiel; Anvari, Arash; Samir, Anthony E; Arellano, Ronald S; Prabhakar, Anand M; Uppot, Raul N

    Image-guided biopsy and ablation relies on successful identification and targeting of lesions. Currently, image-guided procedures are routinely performed under ultrasound, fluoroscopy, magnetic resonance imaging, or computed tomography (CT) guidance. However, these modalities have their limitations including inadequate visibility of the lesion, lesion or organ or patient motion, compatibility of instruments in an magnetic resonance imaging field, and, for CT and fluoroscopy cases, radiation exposure. Recent advances in technology have resulted in the development of a new generation of navigational guidance tools that can aid in targeting lesions for biopsy or ablations. These navigational guidance tools have evolved from simple hand-held trajectory guidance tools, to electronic needle visualization, to image fusion, to the development of a body global positioning system, to growth in cone-beam CT, and to ablation volume planning. These navigational systems are promising technologies that not only have the potential to improve lesion targeting (thereby increasing diagnostic yield of a biopsy or increasing success of tumor ablation) but also have the potential to decrease radiation exposure to the patient and staff, decrease procedure time, decrease the sedation requirements, and improve patient safety. The purpose of this article is to describe the challenges in current standard image-guided techniques, provide a definition and overview for these next-generation navigational devices, and describe the current limitations of these, still evolving, next-generation navigational guidance tools. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Echogenic Catheters and Embryo Transfer Standardization.

    PubMed

    Urbina, Maria Teresa; Benjamin, Isaac; Medina, Randolfo; Lerner, Jorge

    2015-05-01

    1.To describe the standardization process and protocols of the ET method at our center. 2.To compare the performance of non-echogenic catheters with echogenic catheters during ultrasound-guided ET. Retrospective analysis of 2630 ET performed at UNIFERTES during 1997-2014, to describe standardization process and to compare the percentage of difficult ET between echogenic and non-echogenic catheters. We tested 17 non-echogenic and three echogenic catheters. Many variables were associated with the ease of ET: informed patients, waiting time for the procedure, speculum use, clinical touch, uterine contractions, cervical mucus removal, presence of blood before or after the procedure, full bladder, ultrasound guidance, uterocervical angle, mock transfer, catheter type (soft or hard, echogenic or non-echogenic, with stylet or not), catheter loading technique, duration of embryo loading (time interval since the embryos were removed from the incubator for loading until the catheter is passed to the physician), transfer procedure (time interval from the catheter was handed to the physician until the embryos were discharged in the uterus), catheter tip placement, retained embryos, bed rest after ET, operator´s proficiency. The diversity of catheters used and the percentage of difficult transfers decrease as the use of echogenic catheters increases. This process is necessary to minimize variation, ensure high quality, safe and evidence-based practice, and improve outcomes. To standardize the ET method allowed a quicker and easier transfer. The use of echogenic catheters simplified ET procedures guided by abdominal ultrasound.

  19. Advantages of caudal block over intrarectal local anesthesia plus periprostatic nerve block for transrectal ultrasound guided prostate biopsy

    PubMed Central

    Wang, Na; Fu, Yaowen; Ma, Haichun; Wang, Jinguo; Gao, Yang

    2016-01-01

    Objective: To compare caudal block with intrarectal local anesthesia plus periprostatic nerve block for transrectal ultrasound guided prostate biopsy. Methods: One hundred and ninety patients scheduled for transrectal ultrasound guided prostate biopsy were randomized equally into Group-A who received caudal block (20 ml 1.2% lidocaine) and Group-B who received intrarectal local anesthesia (0.3% oxybuprocaine cream) plus periprostatic nerve block (10 ml 1% lidocaine plus 0.5% ropivacaine) before biopsy. During and after the procedure, the patients rated the level of pain/discomfort at various time points. Complications during the whole study period and the patient overall satisfaction were also evaluated. Results: More pain and discomfort was detected during periprostatic nerve block than during caudal block. Pain and discomfort was significantly lower during prostate biopsy and during the manipulation of the probe in the rectum in Group-A than in Group-B. No significant differences were detected in the pain intensity after biopsy and side effects between the two groups. Conclusions: Caudal block provides better anesthesia than periprostatic nerve block plus intrarectal local anesthesia for TRUS guided prostate biopsy without an increase of side effects. PMID:27648052

  20. Efficacy and safety of ultrasound-guided placement of central venous port systems via the right internal jugular vein in elderly oncologic patients: our single-center experience and protocol.

    PubMed

    Canfora, Alfonso; Mauriello, Claudio; Ferronetti, Antonio; Marte, Gianpaolo; Di Maio, Vittorio; Ciorra, Guido; Esposito, Maria Grazia; Giuliano, Maria Elena; Fregola, Giovanni; Barra, Luigi; Cuzzovaglia, Salvatore; Bottino, Vincenzo; Maida, Pietro

    2017-02-01

    Ultrasound-guidance has become the routine method for internal jugular vein (IJV) catheterization reducing dramatically failure and complication rates for central venous port (CVP) placement. The aim of this study was to determine the safety and efficacy of ultrasound-guided IJV CVP placement in elderly oncologic patients. Between January 2013 and December 2015, 101 elderly oncological patients underwent right IJV CVP placement under ultrasound-guidance. The length of catheter introduction ranged from 18 to 21 cm. Intraoperative fluoroscopy (IF) was always performed intraoperatively. Chest X-ray (CXR) was always performed 30 min after the end of the procedure. The morbidity rate was 1.98%; two arterial punctures were reported with one self-limiting hematoma. Two patients (1.98%) had catheter misplacements, recognized by intraoperative IF. No patients (0%) experienced pneumothorax (PNX), confirmed at CXR. Patients were all discharged at maximum 6 h from the procedure. The risk of catheter misplacement, PNX, and arterial/nerve puncture remains present with this technique. Lower rates of catheter misplacement have been reported after right IJV puncture, probably for its straight vertical course. Our results are in accordance with literature (1 counter-lateral subclavian vein and 1 counter-lateral internal jugular vein misplacements). All misplacements were detected intraoperatively. The PNX rates after cannulation of the IJV vary between 0.0 and 0.5%. We had no PNX occurrence. Ultrasonography (US) has improved safety and effectiveness of port system placements. While routine post-procedural CXR seems avoidable, IF should be considered mandatory.

  1. A rare constellation of empyema, lung abscess, and mediastinal abscess as a complication of endobronchial ultrasound-guided transbronchial needle aspiration.

    PubMed

    Huang, Chun-Ta; Chen, Chung-Yu; Ho, Chao-Chi; Yu, Chong-Jen

    2011-07-01

    The introduction of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) brought about significant advancement in the field of bronchoscopy. The major indications for EBUS-TBNA are lung cancer staging and diagnosis of mediastinal lymphadenopathy. This procedure is minimally invasive and cost saving, and no complications have been described in large-scale studies. In this report, we present a case of empyema, lung abscess, and mediastinal abscess that developed in a patient undergoing EBUS-TBNA; the patient subsequently recovered uneventfully after aggressive surgical debridement and antimicrobial therapy. Copyright © 2010 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.

  2. Image fusion and navigation platforms for percutaneous image-guided interventions.

    PubMed

    Rajagopal, Manoj; Venkatesan, Aradhana M

    2016-04-01

    Image-guided interventional procedures, particularly image guided biopsy and ablation, serve an important role in the care of the oncology patient. The need for tumor genomic and proteomic profiling, early tumor response assessment and confirmation of early recurrence are common scenarios that may necessitate successful biopsies of targets, including those that are small, anatomically unfavorable or inconspicuous. As image-guided ablation is increasingly incorporated into interventional oncology practice, similar obstacles are posed for the ablation of technically challenging tumor targets. Navigation tools, including image fusion and device tracking, can enable abdominal interventionalists to more accurately target challenging biopsy and ablation targets. Image fusion technologies enable multimodality fusion and real-time co-displays of US, CT, MRI, and PET/CT data, with navigational technologies including electromagnetic tracking, robotic, cone beam CT, optical, and laser guidance of interventional devices. Image fusion and navigational platform technology is reviewed in this article, including the results of studies implementing their use for interventional procedures. Pre-clinical and clinical experiences to date suggest these technologies have the potential to reduce procedure risk, time, and radiation dose to both the patient and the operator, with a valuable role to play for complex image-guided interventions.

  3. Solid, Cystic, and Tubular: Novice Ultrasound Skills Training Using a Versatile, Affordable Practice Model.

    PubMed

    Sevak, Shruti; Lurvey, Benjamin; Woodfin, Ashley A; Hothem, Zachary; Callahan, Rose E; Robbins, James; Ziegler, Kathryn

    2018-04-09

    In spite of the recognized benefits of ultrasound, many physicians have little experience with using ultrasound to perform procedures. Many medical schools and residency programs lack a formal ultrasound training curriculum. We describe an affordable ultrasound training curriculum and versatile, inexpensive practice model. Participants underwent a didactic session to teach the theory required to perform ultrasound-guided procedures. Motor skills were taught using a practice model incorporating analogs of common anatomic and pathologic structures into an opacified gelatin substrate. The Marcia and Eugene Applebaum Simulation Learning Institute, Beaumont Hospital, Royal Oak, MI; a private nonprofit tertiary care hospital associated with the OUWB School of Medicine, Rochester, MI. The model was tested in a cohort of 50 medical students and general surgery residents. The gelatin model can be constructed for $1.03 per learner. The solid, cystic, and vascular structural analogs were readily identifiable on ultrasound and easily differentiated based on their echotextures. Eighty-four percent of participants successfully aspirated the cystic structure, 88% successfully biopsied a portion of the solid structure, and 76% successfully cannulated the tubular structure. Overall, 82% of participants achieved a passing score for the exercise based on a validated Objective Structured Assessment of Technical Skill instrument. There were no significant differences between the medical students and residents. This model can be used to teach basic ultrasound skills such as aspiration, biopsy, and vessel cannulation, providing a foundation for the use of ultrasound in a broad range of clinical procedures, as well as providing practice opportunities for medical students and residents to gain increased ultrasound competency and confidence. Copyright © 2018 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  4. Learning Ultrasound-Guided Needle Insertion Skills through an Edutainment Game

    NASA Astrophysics Data System (ADS)

    Chan, Wing-Yin; Ni, Dong; Pang, Wai-Man; Qin, Jing; Chui, Yim-Pan; Yu, Simon Chun-Ho; Heng, Pheng-Ann

    Ultrasound-guided needle insertion is essential in many of minimally invasive surgeries or procedures, such as biopsy, drug delivery, spinal anaesthesia, etc. Accurate and safe needle insertion is a difficult task due to the high requirement of hand-eye coordination skills. Many proposed virtual reality (VR) based training systems put their emphasis on realistic simulation instead of pedagogical efficiency. The lack of schematic training scenario leads to boredom of repetitive operations. To solve this, we present our novel training system with the integration of game elements in order to retain the trainees' enthusiasm. Task-oriented scenarios, time attack scenarios and performance evaluation are introduced. Besides, some state-of-art technologies are also presented, including ultrasound simulation, needle haptic rendering as well as a mass-spring-based needle-tissue interaction simulation. These works are shown to be effective to keep the trainees up with learning.

  5. A novel graphical user interface for ultrasound-guided shoulder arthroscopic surgery

    NASA Astrophysics Data System (ADS)

    Tyryshkin, K.; Mousavi, P.; Beek, M.; Pichora, D.; Abolmaesumi, P.

    2007-03-01

    This paper presents a novel graphical user interface developed for a navigation system for ultrasound-guided computer-assisted shoulder arthroscopic surgery. The envisioned purpose of the interface is to assist the surgeon in determining the position and orientation of the arthroscopic camera and other surgical tools within the anatomy of the patient. The user interface features real time position tracking of the arthroscopic instruments with an optical tracking system, and visualization of their graphical representations relative to a three-dimensional shoulder surface model of the patient, created from computed tomography images. In addition, the developed graphical interface facilitates fast and user-friendly intra-operative calibration of the arthroscope and the arthroscopic burr, capture and segmentation of ultrasound images, and intra-operative registration. A pilot study simulating the computer-aided shoulder arthroscopic procedure on a shoulder phantom demonstrated the speed, efficiency and ease-of-use of the system.

  6. On the reproducibility of expert-operated and robotic ultrasound acquisitions.

    PubMed

    Kojcev, Risto; Khakzar, Ashkan; Fuerst, Bernhard; Zettinig, Oliver; Fahkry, Carole; DeJong, Robert; Richmon, Jeremy; Taylor, Russell; Sinibaldi, Edoardo; Navab, Nassir

    2017-06-01

    We present the evaluation of the reproducibility of measurements performed using robotic ultrasound imaging in comparison with expert-operated sonography. Robotic imaging for interventional procedures may be a valuable contribution, but requires reproducibility for its acceptance in clinical routine. We study this by comparing repeated measurements based on robotic and expert-operated ultrasound imaging. Robotic ultrasound acquisition is performed in three steps under user guidance: First, the patient is observed using a 3D camera on the robot end effector, and the user selects the region of interest. This allows for automatic planning of the robot trajectory. Next, the robot executes a sweeping motion following the planned trajectory, during which the ultrasound images and tracking data are recorded. As the robot is compliant, deviations from the path are possible, for instance due to patient motion. Finally, the ultrasound slices are compounded to create a volume. Repeated acquisitions can be performed automatically by comparing the previous and current patient surface. After repeated image acquisitions, the measurements based on acquisitions performed by the robotic system and expert are compared. Within our case series, the expert measured the anterior-posterior, longitudinal, transversal lengths of both of the left and right thyroid lobes on each of the 4 healthy volunteers 3 times, providing 72 measurements. Subsequently, the same procedure was performed using the robotic system resulting in a cumulative total of 144 clinically relevant measurements. Our results clearly indicated that robotic ultrasound enables more repeatable measurements. A robotic ultrasound platform leads to more reproducible data, which is of crucial importance for planning and executing interventions.

  7. System for robot-assisted real-time laparoscopic ultrasound elastography

    NASA Astrophysics Data System (ADS)

    Billings, Seth; Deshmukh, Nishikant; Kang, Hyun Jae; Taylor, Russell; Boctor, Emad M.

    2012-02-01

    Surgical robots provide many advantages for surgery, including minimal invasiveness, precise motion, high dexterity, and crisp stereovision. One limitation of current robotic procedures, compared to open surgery, is the loss of haptic information for such purposes as palpation, which can be very important in minimally invasive tumor resection. Numerous studies have reported the use of real-time ultrasound elastography, in conjunction with conventional B-mode ultrasound, to differentiate malignant from benign lesions. Several groups (including our own) have reported integration of ultrasound with the da Vinci robot, and ultrasound elastography is a very promising image guidance method for robotassisted procedures that will further enable the role of robots in interventions where precise knowledge of sub-surface anatomical features is crucial. We present a novel robot-assisted real-time ultrasound elastography system for minimally invasive robot-assisted interventions. Our system combines a da Vinci surgical robot with a non-clinical experimental software interface, a robotically articulated laparoscopic ultrasound probe, and our GPU-based elastography system. Elasticity and B-mode ultrasound images are displayed as picture-in-picture overlays in the da Vinci console. Our system minimizes dependence on human performance factors by incorporating computer-assisted motion control that automatically generates the tissue palpation required for elastography imaging, while leaving high-level control in the hands of the user. In addition to ensuring consistent strain imaging, the elastography assistance mode avoids the cognitive burden of tedious manual palpation. Preliminary tests of the system with an elasticity phantom demonstrate the ability to differentiate simulated lesions of varied stiffness and to clearly delineate lesion boundaries.

  8. MLESAC Based Localization of Needle Insertion Using 2D Ultrasound Images

    NASA Astrophysics Data System (ADS)

    Xu, Fei; Gao, Dedong; Wang, Shan; Zhanwen, A.

    2018-04-01

    In the 2D ultrasound image of ultrasound-guided percutaneous needle insertions, it is difficult to determine the positions of needle axis and tip because of the existence of artifacts and other noises. In this work the speckle is regarded as the noise of an ultrasound image, and a novel algorithm is presented to detect the needle in a 2D ultrasound image. Firstly, the wavelet soft thresholding technique based on BayesShrink rule is used to denoise the speckle of ultrasound image. Secondly, we add Otsu’s thresholding method and morphologic operations to pre-process the ultrasound image. Finally, the localization of the needle is identified and positioned in the 2D ultrasound image based on the maximum likelihood estimation sample consensus (MLESAC) algorithm. The experimental results show that it is valid for estimating the position of needle axis and tip in the ultrasound images with the proposed algorithm. The research work is hopeful to be used in the path planning and robot-assisted needle insertion procedures.

  9. Ultrasound-guided drainages and sclerotherapy.

    PubMed

    Lohela, P

    2002-02-01

    Ultrasonically guided fluid collection and abscess drainage have become routine procedures in various parts of the body. In most cases ultrasound is the only imaging and guidance modality needed; however, it is of the utmost importance to remember that CT and fluoroscopy with contrast often give invaluable information when the true extent of the process has to be determined and when assessing the safest route for the catheter in anatomically complicated areas. The importance of irrigation of the abscess cavity with fluids and the ready use of urokinase should be emphasized. Ethanol sclerotherapy is a simple and safe procedure to treat symptomatic hepatic or renal cysts. Parathyroid adenomas and cysts, as well as thyroid cysts, can also be treated with ethanol sclerotherapy in selected cases. Purified mineral talc has been used in pleurodesis and hydrocele sclerotherapy, whereas doxycycline or ethanol is used for postoperative lymphoceles. Both abscess drainages and sclerotherapy procedures are minimally invasive, simple, safe, inexpensive and reasonably efficacious treatment in many clinical instances and may be at least an alternative to surgical treatment, often offering significant advantages over surgery.

  10. The Agreement between Auscultation and Lung Ultrasound in Hemodialysis Patients: The LUST Study.

    PubMed

    Torino, Claudia; Gargani, Luna; Sicari, Rosa; Letachowicz, Krzysztof; Ekart, Robert; Fliser, Danilo; Covic, Adrian; Siamopoulos, Kostas; Stavroulopoulos, Aristeidis; Massy, Ziad A; Fiaccadori, Enrico; Caiazza, Alberto; Bachelet, Thomas; Slotki, Itzchak; Martinez-Castelao, Alberto; Coudert-Krier, Marie-Jeanne; Rossignol, Patrick; Gueler, Faikah; Hannedouche, Thierry; Panichi, Vincenzo; Wiecek, Andrzej; Pontoriero, Giuseppe; Sarafidis, Pantelis; Klinger, Marian; Hojs, Radovan; Seiler-Mussler, Sarah; Lizzi, Fabio; Siriopol, Dimitrie; Balafa, Olga; Shavit, Linda; Tripepi, Rocco; Mallamaci, Francesca; Tripepi, Giovanni; Picano, Eugenio; London, Gérard Michel; Zoccali, Carmine

    2016-11-07

    Accumulation of fluid in the lung is the most concerning sequela of volume expansion in patients with ESRD. Lung auscultation is recommended to detect and monitor pulmonary congestion, but its reliability in ESRD is unknown. In a subproject of the ongoing Lung Water by Ultra-Sound Guided Treatment to Prevent Death and Cardiovascular Complications in High Risk ESRD Patients with Cardiomyopathy Trial, we compared a lung ultrasound-guided ultrafiltration prescription policy versus standard care in high-risk patients on hemodialysis. The reliability of peripheral edema was tested as well. This study was on the basis of 1106 pre- and postdialysis lung ultrasound studies (in 79 patients) simultaneous with standardized lung auscultation (crackles at the lung bases) and quantification of peripheral edema. Lung congestion by crackles, edema, or a combination thereof poorly reflected the severity of congestion as detected by ultrasound B lines in various analyses, including standard regression analysis weighting for repeated measures in individual patients (shared variance of 12% and 4% for crackles and edema, respectively) and κ-statistics (κ ranging from 0.00 to 0.16). In general, auscultation had very low discriminatory power for the diagnosis of mild (area under the receiver operating curve =0.61), moderate (area under the receiver operating curve =0.65), and severe (area under the receiver operating curve =0.68) lung congestion, and the same was true for peripheral edema (receiver operating curve =0.56 or lower) and the combination of the two physical signs. Lung crackles, either alone or combined with peripheral edema, very poorly reflect interstitial lung edema in patients with ESRD. These findings reinforce the rationale underlying the Lung Water by Ultra-Sound Guided Treatment to Prevent Death and Cardiovascular Complications in High Risk ESRD Patients with Cardiomyopathy Trial, a trial adopting ultrasound B lines as an instrument to guide interventions aimed at mitigating lung congestion in high-risk patients on hemodialysis. Copyright © 2016 by the American Society of Nephrology.

  11. Comparative-Effectiveness of Simulation-Based Deliberate Practice Versus Self-Guided Practice on Resident Anesthesiologists' Acquisition of Ultrasound-Guided Regional Anesthesia Skills.

    PubMed

    Udani, Ankeet Deepak; Harrison, T Kyle; Mariano, Edward R; Derby, Ryan; Kan, Jack; Ganaway, Toni; Shum, Cynthia; Gaba, David M; Tanaka, Pedro; Kou, Alex; Howard, Steven K

    2016-01-01

    Simulation-based education strategies to teach regional anesthesia have been described, but their efficacy largely has been assumed. We designed this study to determine whether residents trained using the simulation-based strategy of deliberate practice show greater improvement of ultrasound-guided regional anesthesia (UGRA) skills than residents trained using self-guided practice in simulation. Anesthesiology residents new to UGRA were randomized to participate in either simulation-based deliberate practice (intervention) or self-guided practice (control). Participants were recorded and assessed while performing simulated peripheral nerve blocks at baseline, immediately after the experimental condition, and 3 months after enrollment. Subject performance was scored from video by 2 blinded reviewers using a composite tool. The amount of time each participant spent in deliberate or self-guided practice was recorded. Twenty-eight participants completed the study. Both groups showed within-group improvement from baseline scores immediately after the curriculum and 3 months following study enrollment. There was no difference between groups in changed composite scores immediately after the curriculum (P = 0.461) and 3 months following study enrollment (P = 0.927) from baseline. The average time in minutes that subjects spent in simulation practice was 6.8 minutes for the control group compared with 48.5 minutes for the intervention group (P < 0.001). In this comparative effectiveness study, there was no difference in acquisition and retention of skills in UGRA for novice residents taught by either simulation-based deliberate practice or self-guided practice. Both methods increased skill from baseline; however, self-guided practice required less time and faculty resources.

  12. Ultrasound-guided core needle biopsy in diagnosis of abdominal and pelvic neoplasm in pediatric patients.

    PubMed

    Wang, Hailing; Li, Fangxuan; Liu, Juntian; Zhang, Sheng

    2014-01-01

    Ultrasound-guided core needle biopsy of abdominal and pelvic masses in adults has gained tremendous popularity. However, the application of the same treatment in children is not as popular because of apprehensions regarding inadequate tissues for the biopsy and accidental puncture of vital organs. Data of the application of ultrasound-guided core needle biopsy in 105 pediatric patients with clinically or ultrasound-diagnosed abdominopelvic masses were reviewed. Diagnostic procedures were conducted in our institution from May 2011 to May 2013. The biopsies were conducted on 86 malignant lesions and 19 benign lesions. 86 malignant tumors comprised neuroblastomas (30 cases), hepatoblastomas (15 cases), nephroblastomas (11 cases), and primitive neuroectodermal tumors/malignant small round cells (6 cases). Among malignant tumor cases, only a pelvic primitive neuroectodermal tumor did not receive a pathological diagnosis. Therefore, the biopsy accuracy was 98.8 % in malignant tumor. However, the biopsies for one neuroblastomas and one malignant small round cell tumor were inadequate for cytogenetic analysis. Therefore, 96.5 % of the malignant tumor patients received complete diagnosis via biopsy. 19 benign tumors comprised mature teratoma (10 cases), hemangioendothelioma (3 cases), paraganglioma (2 cases), and infection (2 cases). The diagnostic accuracy for benign neoplasm was 100 %. Five patients experienced postoperative complications, including pain (2 patients), bleeding from the biopsy site (2 patients), and wound infection (1 patient). Ultrasound-guided core needle biopsy is an efficient, minimally invasive, accurate, and safe diagnostic method that can be applied in the management of abdominal or pelvic mass of pediatric patients.

  13. Synthetic aperture imaging in ultrasound calibration

    NASA Astrophysics Data System (ADS)

    Ameri, Golafsoun; Baxter, John S. H.; McLeod, A. Jonathan; Jayaranthe, Uditha L.; Chen, Elvis C. S.; Peters, Terry M.

    2014-03-01

    Ultrasound calibration allows for ultrasound images to be incorporated into a variety of interventional applica­ tions. Traditional Z- bar calibration procedures rely on wired phantoms with an a priori known geometry. The line fiducials produce small, localized echoes which are then segmented from an array of ultrasound images from different tracked probe positions. In conventional B-mode ultrasound, the wires at greater depths appear blurred and are difficult to segment accurately, limiting the accuracy of ultrasound calibration. This paper presents a novel ultrasound calibration procedure that takes advantage of synthetic aperture imaging to reconstruct high resolution ultrasound images at arbitrary depths. In these images, line fiducials are much more readily and accu­ rately segmented, leading to decreased calibration error. The proposed calibration technique is compared to one based on B-mode ultrasound. The fiducial localization error was improved from 0.21mm in conventional B-mode images to 0.15mm in synthetic aperture images corresponding to an improvement of 29%. This resulted in an overall reduction of calibration error from a target registration error of 2.00mm to 1.78mm, an improvement of 11%. Synthetic aperture images display greatly improved segmentation capabilities due to their improved resolution and interpretability resulting in improved calibration.

  14. TU-EF-210-04: AAPM Task Groups in Interventional Ultrasound Imaging and Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Farahani, K.

    The use of therapeutic ultrasound to provide targeted therapy is an active research area that has a broad application scope. The invited talks in this session will address currently implemented strategies and protocols for both hyperthermia and ablation applications using therapeutic ultrasound. The role of both ultrasound and MRI in the monitoring and assessment of these therapies will be explored in both pre-clinical and clinical applications. Katherine Ferrara: High Intensity Focused Ultrasound, Drug Delivery, and Immunotherapy Rajiv Chopra: Translating Localized Doxorubicin Delivery to Pediatric Oncology using MRI-guided HIFU Elisa Konofagou: Real-time Ablation Monitoring and Lesion Quantification using Harmonic Motion Imagingmore » Keyvan Farahani: AAPM Task Groups in Interventional Ultrasound Imaging and Therapy Learning Objectives: Understand the role of ultrasound in localized drug delivery and the effects of immunotherapy when used in conjunction with ultrasound therapy. Understand potential targeted drug delivery clinical applications including pediatric oncology. Understand the technical requirements for performing targeted drug delivery. Understand how radiation-force approaches can be used to both monitor and assess high intensity focused ultrasound ablation therapy. Understand the role of AAPM task groups in ultrasound imaging and therapies. Chopra: Funding from Cancer Prevention and Research Initiative of Texas (CPRIT), Award R1308 Evelyn and M.R. Hudson Foundation; Research Support from Research Contract with Philips Healthcare; COI are Co-founder of FUS Instruments Inc Ferrara: Supported by NIH, UCDavis and California (CIRM and BHCE) Farahani: In-kind research support from Philips Healthcare.« less

  15. Holistic ultrasound in trauma: An update.

    PubMed

    Saranteas, Theodosios; Mavrogenis, Andreas F

    2016-10-01

    Holistic ultrasound is a total body examination using an ultrasound device aiming to achieve immediate patient care and decision making. In the setting of trauma, it is one of the most fundamental components of care of the injured patients. Ground-breaking imaging software allows physicians to examine various organs thoroughly, recognize imaging signs early, and potentially foresee the onset or the possible outcome of certain types of injuries. Holistic ultrasound can be performed on a routine basis at the bedside of the patients, at admission and during the perioperative period. Trauma care physicians should be aware of the diagnostic and guidance benefits of ultrasound and should receive appropriate training for the optimal management of their patients. In this paper, the findings of holistic ultrasound in trauma patients are presented, with emphasis on the lungs, heart, cerebral circulation, abdomen, and airway. Additionally, the benefits of ultrasound imaging in interventional anaesthesia techniques such as ultrasound-guided peripheral nerve blocks and central vein catheterization are described. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. The utility of ultrasound in patients with melanoma.

    PubMed

    Uren, Roger F; Sanki, Amira; Thompson, John F

    2007-11-01

    The highest quality gray-scale ultrasound images are obtained with high-frequency transducers; however, such high frequencies do not penetrate more than a few centimeters into body tissue. Fortunately, in patients with melanoma, the structures of interest are close to the skin surface, making them ideal targets for examination with high-resolution ultrasound. These include primary cutaneous melanomas, uveal melanomas and the regional lymph nodes draining the skin that lie in the axilla, groin, neck and other locations. Although ultrasound study of primary melanomas arising in the skin and eye has provided some insights, a major role for ultrasound has evolved recently, to provide early detection of metastatic melanoma in regional lymph nodes. Ultrasound is clearly superior to clinical palpation of the nodes during follow-up and, when combined with guided fine-needle biopsy, allows the earliest possible surgical intervention for regional nodal metastases. In the future the use of ultrasound contrast agents may improve the sensitivity of ultrasound in the detection of very small metastatic deposits.

  17. Ultrasound imaging-guided intracardiac injection to develop a mouse model of breast cancer brain metastases followed by longitudinal MRI.

    PubMed

    Zhou, Heling; Zhao, Dawen

    2014-03-06

    Breast cancer brain metastasis, occurring in 30% of breast cancer patients at stage IV, is associated with high mortality. The median survival is only 6 months. It is critical to have suitable animal models to mimic the hemodynamic spread of the metastatic cells in the clinical scenario. Here, we are introducing the use of small animal ultrasound imaging to guide an accurate injection of brain tropical breast cancer cells into the left ventricle of athymic nude mice. Longitudinal MRI is used to assessing intracranial initiation and growth of brain metastases. Ultrasound-guided intracardiac injection ensures not only an accurate injection and hereby a higher successful rate but also significantly decreased mortality rate, as compared to our previous manual procedure. In vivo high resolution MRI allows the visualization of hyperintense multifocal lesions, as small as 310 µm in diameter on T2-weighted images at 3 weeks post injection. Follow-up MRI reveals intracranial tumor growth and increased number of metastases that distribute throughout the whole brain.

  18. Cost comparison between ultrasound-guided 14-g large core breast biopsy and open surgical biopsy: an analysis for Austria.

    PubMed

    Gruber, R; Walter, E; Helbich, T H

    2010-06-01

    To examine the budget impact of ultrasound-guided 14-g large core breast biopsy (US-guided LCBB) by comparing the costs of US-guided LCBB and open surgical biopsy (OSB); to calculate the cost savings attributable to US-guided LCBB; and to assess the frequency with which US-guided LCBB obviates the need for an OSB. In a retrospective study, we reviewed 399 suspicious breast lesions on which US-guided LCBB and OSB or, in cases of benign histology, clinical follow-up, were performed. Cost savings were calculated using nationally allowed flat rates (A-drg) and patient charges. Costs were measured from both, a hospital and a socioeconomic perspective. Deterministic sensitivity analyses were simulated to assess the extent of achievable cost savings. Overall cost savings for US-guided LCBB over OSB were euro 977 (euro 2,337/euro 3,314) per case from a hospital perspective, resulting in a total cost decrease of 30% for the diagnosis of suspicious breast lesions. From a socioeconomic perspective, cost savings were euro 1,542 (euro 2,600/euro 4,142) per case, resulting in a 37% reduction in biopsy cost. US-guided LCBB obviated the need for a surgical procedure in 240 (60%) of 399 women. In all four sensitivity analyses, costs of US-guided LCBB remained lower than that of OSB. From an economic perspective, US-guided LCBB is highly recommended for the diagnosis of suspicious breast lesions, as this procedure reduces the cost of diagnosis substantially. In Austria, annual cost savings would be euro 18.5 million. Copyright (c) 2009 Elsevier Ireland Ltd. All rights reserved.

  19. Ultrasound-Guided Regional Anesthesia Simulation Training: A Systematic Review.

    PubMed

    Chen, Xiao Xu; Trivedi, Vatsal; AlSaflan, AbdulHadi A; Todd, Suzanne Clare; Tricco, Andrea C; McCartney, Colin J L; Boet, Sylvain

    Ultrasound-guided regional anesthesia (UGRA) has become the criterion standard of regional anesthesia practice. Ultrasound-guided regional anesthesia teaching programs often use simulation, and guidelines have been published to help guide URGA education. This systematic review aimed to examine the effectiveness of simulation-based education for the acquisition and maintenance of competence in UGRA. Studies identified in MEDLINE, EMBASE, CINAHL, Cochrane Central Register of Controlled Trials, and ERIC were included if they assessed simulation-based UGRA teaching with outcomes measured at Kirkpatrick level 2 (knowledge and skills), 3 (transfer of learning to the workplace), or 4 (patient outcomes). Two authors independently reviewed all identified references for eligibility, abstracted data, and appraised quality. After screening 176 citations and 45 full-text articles, 12 studies were included. Simulation-enhanced training improved knowledge acquisition (Kirkpatrick level 2) when compared with nonsimulation training. Seven studies measuring skill acquisition (Kirkpatrick level 2) found that simulation-enhanced UGRA training was significantly more effective than alternative teaching methods or no intervention. One study measuring transfer of learning into the clinical setting (Kirkpatrick level 3) found no difference between simulation-enhanced UGRA training and non-simulation-based training. However, this study was discontinued early because of technical challenges. Two studies examined patient outcomes (Kirkpatrick level 4), and one of these found that simulation-based UGRA training improved patient outcomes compared with didactic teaching. Ultrasound-guided regional anesthesia knowledge and skills significantly improved with simulation training. The acquired UGRA skills may be transferred to the clinical setting; however, further studies are required to confirm these changes translate to improved patient outcomes.

  20. One-stage hybrid surgery for acute Stanford type A aortic dissection with David operation, aortic arch debranching, and endovascular graft: a case report

    PubMed Central

    Liu, Lulu; Qin, Chaoyi; Hou, Jianglong; Zhu, Da; Zhang, Bengui; Ma, Hao

    2016-01-01

    Acute Stanford type A aortic dissection requires an extremely complex surgical strategy and presents high risk of complications. Although many different procedures were reported to treat this aortic dissection, high mortality rate and incidences of complications still exist. This study presents a 59-year-old lady with acute Stanford type A aortic dissection, which originated from the aortic root to proximal part of right external iliac artery and involved the brachiocephalic trunk, left carotid artery, celiac trunk, and left renal artery. The patient underwent one-stage hybrid surgery of David procedures, debranching, and endovascular aortic repair under ultrasound-guided aortic arch cannulation cardiopulmonary bypass (CPB). The surgery was successfully performed, and the patient showed no post-operative complication. The one-staged hybrid surgery of David procedures, debranching, and endovascular aortic repair provides novel and well-designed combined techniques for treating complex acute Stanford type A aortic dissection. Our techniques significantly lowered the risks, thereby expanding the indications of surgical intervention for acute Stanford type A aortic dissection. PMID:28149590

  1. MRI-powered biomedical devices.

    PubMed

    Hovet, Sierra; Ren, Hongliang; Xu, Sheng; Wood, Bradford; Tokuda, Junichi; Tse, Zion Tsz Ho

    2017-11-16

    Magnetic resonance imaging (MRI) is beneficial for imaging-guided procedures because it provides higher resolution images and better soft tissue contrast than computed tomography (CT), ultrasound, and X-ray. MRI can be used to streamline diagnostics and treatment because it does not require patients to be repositioned between scans of different areas of the body. It is even possible to use MRI to visualize, power, and control medical devices inside the human body to access remote locations and perform minimally invasive procedures. Therefore, MR conditional medical devices have the potential to improve a wide variety of medical procedures; this potential is explored in terms of practical considerations pertaining to clinical applications and the MRI environment. Recent advancements in this field are introduced with a review of clinically relevant research in the areas of interventional tools, endovascular microbots, and closed-loop controlled MRI robots. Challenges related to technology and clinical feasibility are discussed, including MRI based propulsion and control, navigation of medical devices through the human body, clinical adoptability, and regulatory issues. The development of MRI-powered medical devices is an emerging field, but the potential clinical impact of these devices is promising.

  2. One-stage hybrid surgery for acute Stanford type A aortic dissection with David operation, aortic arch debranching, and endovascular graft: a case report.

    PubMed

    Liu, Lulu; Qin, Chaoyi; Hou, Jianglong; Zhu, Da; Zhang, Bengui; Ma, Hao; Guo, Yingqiang

    2016-12-01

    Acute Stanford type A aortic dissection requires an extremely complex surgical strategy and presents high risk of complications. Although many different procedures were reported to treat this aortic dissection, high mortality rate and incidences of complications still exist. This study presents a 59-year-old lady with acute Stanford type A aortic dissection, which originated from the aortic root to proximal part of right external iliac artery and involved the brachiocephalic trunk, left carotid artery, celiac trunk, and left renal artery. The patient underwent one-stage hybrid surgery of David procedures, debranching, and endovascular aortic repair under ultrasound-guided aortic arch cannulation cardiopulmonary bypass (CPB). The surgery was successfully performed, and the patient showed no post-operative complication. The one-staged hybrid surgery of David procedures, debranching, and endovascular aortic repair provides novel and well-designed combined techniques for treating complex acute Stanford type A aortic dissection. Our techniques significantly lowered the risks, thereby expanding the indications of surgical intervention for acute Stanford type A aortic dissection.

  3. A randomised crossover study to compare the cross-sectional and longitudinal approaches to ultrasound-guided peripheral venepuncture in a model.

    PubMed

    Griffiths, James; Carnegie, Amadeus; Kendall, Richard; Madan, Rajeev

    2017-12-01

    Ultrasound-guided peripheral intravenous access may present an alternative to central or intraosseous access in patients with difficult peripheral veins. Using venepuncture of a phantom model as a proxy, we investigated whether novice ultrasound users should adopt a cross-sectional or longitudinal approach when learning to access peripheral veins under ultrasound guidance. This result would inform the development of a structured training method for this procedure. We conducted a randomised controlled trial of 30 medical students. Subjects received 35 min of training, then attempted to aspirate 1 ml of synthetic blood from a deep vein in a training model under ultrasound guidance. Subjects attempted both the cross-sectional and longitudinal approaches. Group 1 used cross-sectional first, followed by longitudinal. Group 2 used longitudinal first, then cross-sectional. We measured the time from first puncture of the model's skin to aspiration of fluid, and the number of attempts required. Subjects also reported difficulty ratings for each approach. Paired sample t-tests were used for statistical analysis. The mean number of attempts was 1.13 using the cross-sectional approach, compared with 1.30 using the longitudinal approach (p = 0.17). Mean time to aspiration of fluid was 45.1 s using the cross-sectional approach and 52.8 s using the longitudinal approach (p = 0.43). The mean difficulty score out of 10 was 3.97 for the cross-sectional approach and 3.93 for the longitudinal approach (p = 0.95). We found no significant difference in effectiveness between the cross-sectional and longitudinal approaches to ultrasound-guided venepuncture when performed on a model. We believe that both approaches should be included when teaching ultrasound-guided peripheral vascular access. To confirm which approach would be best in clinical practice, we advocate future testing of both approaches on patients.

  4. Evaluation of cost-effectiveness from the funding body's point of view of ultrasound-guided central venous catheter insertion compared with the conventional technique.

    PubMed

    Noritomi, Danilo Teixeira; Zigaib, Rogério; Ranzani, Otavio T; Teich, Vanessa

    2016-01-01

    To evaluate the cost-effectiveness, from the funding body's point of view, of real-time ultrasound-guided central venous catheter insertion compared to the traditional method, which is based on the external anatomical landmark technique. A theoretical simulation based on international literature data was applied to the Brazilian context, i.e., the Unified Health System (Sistema Único de Saúde - SUS). A decision tree was constructed that showed the two central venous catheter insertion techniques: real-time ultrasonography versus external anatomical landmarks. The probabilities of failure and complications were extracted from a search on the PubMed and Embase databases, and values associated with the procedure and with complications were taken from market research and the Department of Information Technology of the Unified Health System (DATASUS). Each central venous catheter insertion alternative had a cost that could be calculated by following each of the possible paths on the decision tree. The incremental cost-effectiveness ratio was calculated by dividing the mean incremental cost of real-time ultrasound compared to the external anatomical landmark technique by the mean incremental benefit, in terms of avoided complications. When considering the incorporation of real-time ultrasound and the concomitant lower cost due to the reduced number of complications, the decision tree revealed a final mean cost for the external anatomical landmark technique of 262.27 Brazilian reals (R$) and for real-time ultrasound of R$187.94. The final incremental cost of the real-time ultrasound-guided technique was -R$74.33 per central venous catheter. The incremental cost-effectiveness ratio was -R$2,494.34 due to the pneumothorax avoided. Real-time ultrasound-guided central venous catheter insertion was associated with decreased failure and complication rates and hypothetically reduced costs from the view of the funding body, which in this case was the SUS.

  5. Ultrasound-Guided Intermediate Site Greater Occipital Nerve Infiltration: A Technical Feasibility Study.

    PubMed

    Zipfel, Jonathan; Kastler, Adrian; Tatu, Laurent; Behr, Julien; Kechidi, Rachid; Kastler, Bruno

    2016-01-01

    Two studies recently reported that computed tomography (CT) guided infiltration of the greater occipital nerve at its intermediate site allows a high efficacy rate with long-lasting pain relief following procedure in occipital neuralgia and in various craniofacial pain syndromes. The purpose of our study was to evaluate the technical feasibility and safety of ultrasound-guided intermediate site greater occipital nerve infiltration. Retrospective study. This study was conducted at the imaging department of a 1,409 bed university hospital. Local institutional review board approval was obtained and written consent was waived. In this retrospective study, 12 patients suffering from refractory occipital neuralgia or craniofacial pain syndromes were included between April and October 2014. They underwent a total of 21 ultrasound-guided infiltrations. Infiltration of the greater occipital nerve was performed at the intermediate site of the greater occipital nerve, at its first bend between obliqus capitis inferior and semispinalis capitis muscles with local anestetics and cortivazol. Technical success was defined as satisfactory diffusion of added iodinated contrast media in the fatty space between these muscles depicted on control CT scan. We also reported first data of immediate block test efficacy and initial clinical efficacy at 7 days, one month, and 3 months, defined by a decrease of at least 50% of visual analog scale (VAS) scores. Technical success rate was 95.24%. Patients suffered from right unilateral occipital neuralgia in 3 cases, left unilateral occipital neuralgia in 2 cases, bilateral occipital neuralgia in 2 cases, migraine in one case, cervicogenic headache in one case, tension-type headache in 2 cases, and cluster headache in one case. Block test efficacy was found in 93.3% (14/15) cases. Clinical efficacy was found in 80% of cases at 7 days, in 66.7% of cases at one month and in 60% of cases at 3 months. No major complications were noted. Some of the limitations of our study include that it represents a single institution. The low number of infiltrations included in this study, for this guidance procedure, is another bias. This ultrasound-guided infiltration technique appears to be feasible, safe, non-ionizing, and fast when targeting the greater occipital nerve in its intermediate portion. This imaging guidance modality should be used in routine clinical practice. Greater occipital nerve, infiltration, ultrasound guidance, corticosteroids, occipital neuralgia, craniofacial pain syndrome.

  6. Ultrasound-Guided Thrombin Injection Is a Safe and Effective Treatment for Femoral Artery Pseudoaneurysm in the Morbidly Obese.

    PubMed

    Yoo, Taehwan; Starr, Jean E; Go, Michael R; Vaccaro, Patrick S; Satiani, Bhagwan; Haurani, Mounir J

    2017-08-01

    Ultrasound-guided thrombin injection (UGTI) is a well-established practice for the treatment of femoral artery pseudoaneurysm. This procedure is highly successful but dependent on appropriate pseudoaneurysm anatomy and adequate ultrasound visualization. Morbid obesity can present a significant technical challenge due to increased groin adiposity, resulting in poor visualization of critical structures needed to safely perform the procedure. We aim to evaluate the safety and efficacy of UGTI to treat femoral artery pseudoaneurysm in the morbidly obese. This is a retrospective cohort study in which all patients who underwent UGTI at The Ohio State University Ross Heart Hospital from 2009 to 2014 were analyzed for patient characteristics and stratified by body mass index (BMI). Patients with BMI ≥ 35 were considered morbidly obese and were compared to patients with a BMI < 35. Outcome was failed treatment resulting in residual pseudoaneurysm. Our cohort consisted of 54 patients who underwent thrombin injection. There were 41 nonmorbidly obese and 13 morbidly obese patients. Mean age was 64.5 years. The cohort was 44.4% male. There were 6 failures, of which 1 underwent successful repeat injection and 5 underwent open surgical repair. There was no statistically significant difference in failure between nonmorbidly obese and morbidly obese patients (9.8% vs 15.4%, P = .45). There were no embolic/thrombotic complications. Ultrasound-guided thrombin injection is a safe and effective therapy in the morbidly obese for the treatment of femoral artery pseudoaneurysm. In the hands of experienced sonographers and surgeons with adequate visualization of the pseudoaneurysm sac, UGTI should remain a standard therapy in the morbidly obese.

  7. Robotic Arm-Assisted Sonography: Review of Technical Developments and Potential Clinical Applications.

    PubMed

    Swerdlow, Daniel R; Cleary, Kevin; Wilson, Emmanuel; Azizi-Koutenaei, Bamshad; Monfaredi, Reza

    2017-04-01

    Ultrasound imaging requires trained personnel. Advances in robotics and data transmission create the possibility of telesonography. This review introduces clinicians to current technical work in and potential applications of this developing capability. Telesonography offers advantages in hazardous or remote environments. Robotically assisted ultrasound can reduce stress injuries in sonographers and has potential utility during robotic surgery and interventional procedures.

  8. Value of MR contrast media in image-guided body interventions.

    PubMed

    Saeed, Maythem; Wilson, Mark

    2012-01-28

    In the past few years, there have been multiple advances in magnetic resonance (MR) instrumentation, in vivo devices, real-time imaging sequences and interventional procedures with new therapies. More recently, interventionists have started to use minimally invasive image-guided procedures and local therapies, which reduce the pain from conventional surgery and increase drug effectiveness, respectively. Local therapy also reduces the systemic dose and eliminates the toxic side effects of some drugs to other organs. The success of MR-guided procedures depends on visualization of the targets in 3D and precise deployment of ablation catheters, local therapies and devices. MR contrast media provide a wealth of tissue contrast and allows 3D and 4D image acquisitions. After the development of fast imaging sequences, the clinical applications of MR contrast media have been substantially expanded to include pre- during- and post-interventions. Prior to intervention, MR contrast media have the potential to localize and delineate pathologic tissues of vital organs, such as the brain, heart, breast, kidney, prostate, liver and uterus. They also offer other options such as labeling therapeutic agents or cells. During intervention, these agents have the capability to map blood vessels and enhance the contrast between the endovascular guidewire/catheters/devices, blood and tissues as well as direct therapies to the target. Furthermore, labeling therapeutic agents or cells aids in visualizing their delivery sites and tracking their tissue distribution. After intervention, MR contrast media have been used for assessing the efficacy of ablation and therapies. It should be noted that most image-guided procedures are under preclinical research and development. It can be concluded that MR contrast media have great value in preclinical and some clinical interventional procedures. Future applications of MR contrast media in image-guided procedures depend on their safety, tolerability, tissue specificity and effectiveness in demonstrating success of the interventions and therapies.

  9. Treatment of cervical pregnancy with ultrasound-guided local methotrexate injection.

    PubMed

    Yamaguchi, M; Honda, R; Erdenebaatar, C; Monsur, M; Honda, T; Sakaguchi, I; Okamura, Y; Ohba, T; Katabuchi, H

    2017-12-01

    Cervical pregnancy (CP) is a rare type of ectopic pregnancy. While methotrexate (MTX) is generally the first-line method of choice for clinically stable women, there is still no consensus on the most appropriate treatment for this abnormal pregnancy. The aim of this study was to investigate the efficacy of a single local MTX injection under transvaginal ultrasound guidance for the initial treatment of CP and to assess post-treatment fertility. We reviewed retrospectively 15 patients with CP treated with local MTX injection under transvaginal ultrasound guidance. In all patients, the serum human chorionic gonadotropin (hCG) levels were monitored and the gestational sac was evaluated using ultrasonography after treatment. Magnetic resonance imaging (MRI) was performed as necessary. We evaluated the patients' clinical characteristics and clinical course after treatment, the efficacy of the treatment and the post-treatment fertility in patients desiring subsequent pregnancy. The median estimated gestational age at the time of MTX injection was 6 + 2 (range, 5 + 2 to 11 + 0) weeks. All 15 patients were treated successfully, without the need for blood transfusion or surgical procedures; however, three patients required an additional local MTX injection due to a poor decline in serum hCG level following the initial injection, while one patient required uterine artery embolization due to persistent vaginal bleeding and an enlarging gestational sac with blood vessels visible on contrast-enhanced MRI. The mean time following initial MTX injection for hCG normalization was 43.8 (95% CI, 33.3-54.3) days and for resumption of menses was 68.4 (95% CI, 51.9-84.9) days. Seven of the 10 women desiring subsequent pregnancy following treatment had uneventful pregnancy, one became pregnant but miscarried spontaneously at 8 weeks of gestation, one was treated by laparoscopic surgery after diagnosis of a tubal pregnancy and one did not conceive. A single, ultrasound-guided, local MTX injection is apparently effective for the treatment of CP without the need for concomitant procedures or surgical intervention. Furthermore, this conservative technique both preserves fertility and allows for the possibility of subsequent uneventful pregnancy. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd.

  10. Utility and Safety of Endoscopic Ultrasound With Bronchoscope-Guided Fine-Needle Aspiration in Mediastinal Lymph Node Sampling: Systematic Review and Meta-Analysis.

    PubMed

    Dhooria, Sahajal; Aggarwal, Ashutosh N; Gupta, Dheeraj; Behera, Digambar; Agarwal, Ritesh

    2015-07-01

    The use of endoscopic ultrasound with bronchoscope-guided fine-needle aspiration (EUS-B-FNA) has been described in the evaluation of mediastinal lymphadenopathy. Herein, we conduct a meta-analysis to estimate the overall diagnostic yield and safety of EUS-B-FNA combined with endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA), in the diagnosis of mediastinal lymphadenopathy. The PubMed and EmBase databases were searched for studies reporting the outcomes of EUS-B-FNA in diagnosis of mediastinal lymphadenopathy. The study quality was assessed using the QualSyst tool. The yield of EBUS-TBNA alone and the combined procedure (EBUS-TBNA and EUS-B-FNA) were analyzed by calculating the sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio for each study, and pooling the study results using a random effects model. Heterogeneity and publication bias were assessed for individual outcomes. The additional diagnostic gain of EUS-B-FNA over EBUS-TBNA was calculated using proportion meta-analysis. Our search yielded 10 studies (1,080 subjects with mediastinal lymphadenopathy). The sensitivity of the combined procedure was significantly higher than EBUS-TBNA alone (91% vs 80%, P = .004), in staging of lung cancer (4 studies, 465 subjects). The additional diagnostic gain of EUS-B-FNA over EBUS-TBNA was 7.6% in the diagnosis of mediastinal adenopathy. No serious complication of EUS-B-FNA procedure was reported. Clinical and statistical heterogeneity was present without any evidence of publication bias. Combining EBUS-TBNA and EUS-B-FNA is an effective and safe method, superior to EBUS-TBNA alone, in the diagnosis of mediastinal lymphadenopathy. Good quality randomized controlled trials are required to confirm the results of this systematic review. Copyright © 2015 by Daedalus Enterprises.

  11. Ultrasound Guidance for Botulinum Neurotoxin Chemodenervation Procedures.

    PubMed

    Alter, Katharine E; Karp, Barbara I

    2017-12-28

    Injections of botulinum neurotoxins (BoNTs) are prescribed by clinicians for a variety of disorders that cause over-activity of muscles; glands; pain and other structures. Accurately targeting the structure for injection is one of the principle goals when performing BoNTs procedures. Traditionally; injections have been guided by anatomic landmarks; palpation; range of motion; electromyography or electrical stimulation. Ultrasound (US) based imaging based guidance overcomes some of the limitations of traditional techniques. US and/or US combined with traditional guidance techniques is utilized and or recommended by many expert clinicians; authors and in practice guidelines by professional academies. This article reviews the advantages and disadvantages of available guidance techniques including US as well as technical aspects of US guidance and a focused literature review related to US guidance for chemodenervation procedures including BoNTs injection.

  12. Ultrasound-guided versus fluoroscopy-guided sacroiliac joint intra-articular injections in the noninflammatory sacroiliac joint dysfunction: a prospective, randomized, single-blinded study.

    PubMed

    Jee, Haemi; Lee, Ji-Hae; Park, Ki Deok; Ahn, Jaeki; Park, Yongbum

    2014-02-01

    To compare the short-term effects and safety of ultrasound (US)-guided sacroiliac joint (SIJ) injections with fluoroscopy (FL)-guided SIJ injections in patients with noninflammatory SIJ dysfunction. Prospective, randomized controlled trial. University hospital. Patients (N=120) with noninflammatory sacroiliac arthritis were enrolled. All procedures were performed using an FL or US apparatus. Subjects were randomly assigned to either the FL or US group. Immediately after the SIJ injections, fluoroscopy was applied to verify the correct placement of the injected medication and intravascular injections. Treatment effects and functional improvement were compared at 2 and 12 weeks after the procedures. The verbal numeric pain scale and Oswestry Disability Index improved at 2 and 12 weeks after the injections without statistical significances between groups. Of 55 US-guided injections, 48 (87.3%) were successful and 7 (12.7%) were missed. The FL-guided SIJ approach exhibited a greater accuracy (98.2%) than the US-guided approach. Vascularization around the SIJ was seen in 34 of 55 patients. Among the 34 patients, 7 had vascularization inside the joint, 23 had vascularization around the joint, and 4 had vascularization both inside and around the joint. Three cases of intravascular injections occurred in the FL group. The US-guided approach may facilitate the identification and avoidance of the critical vessels around or within the SIJ. Function and pain relief significantly improved in both groups without significant differences between groups. The US-guided approach was shown to be as effective as the FL-guided approach in treatment effects. However, diagnostic application in the SIJ may be limited because of the significantly lower accuracy rate (87.3%). Copyright © 2014 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  13. Differences in accuracy and underestimation rates for 14- versus 16-gauge core needle biopsies in ultrasound-detectable breast lesions.

    PubMed

    Lai, Hung-Wen; Wu, Hwa-Koon; Kuo, Shou-Jen; Chen, Shou-Tung; Tseng, Hsin-Shun; Tseng, Ling-Ming; Chen, Dar-Ren

    2013-04-01

    Core needle biopsy (CNB) was widely used in the diagnosis of ultrasound-detectable breast lesions. We aimed at assessing the diagnostic performance differences between 14- and 16-gauge ultrasound-guided core biopsies. This retrospective study enrolled patients receiving CNB from January 2001 to December 2007. The results of 14- and 16-gauge breast CNBs were compared with pathology reports of open surgical biopsy (OSB). A total of 1024 paired CNB and OSB results were obtained from 1732 CNB procedures in 1630 patients.Those CNB results reached 92.9% sensitivity, 99.7% specificity, 5.96% underestimation, and 94.8% accuracy rates. There was no difference in sensitivity (p=0.17) or specificity (p=0.38) between 14- and 16-gauge needles. However, better overall accuracy (p=0.02), less underestimation (p<0.001), and lower false-negative (p=0.02) rates were found for the 14-gauge CNB. Regarding accuracy and underestimation rates, a 14-gauge needle is preferred to a 16-gauge one in ultrasound-guided biopsies. Copyright © 2012. Published by Elsevier B.V.

  14. Paraffin-gel tissue-mimicking material for ultrasound-guided needle biopsy phantom.

    PubMed

    Vieira, Sílvio L; Pavan, Theo Z; Junior, Jorge E; Carneiro, Antonio A O

    2013-12-01

    Paraffin-gel waxes have been investigated as new soft tissue-mimicking materials for ultrasound-guided breast biopsy training. Breast phantoms were produced with a broad range of acoustical properties. The speed of sound for the phantoms ranged from 1425.4 ± 0.6 to 1480.3 ± 1.7 m/s at room temperature. The attenuation coefficients were easily controlled between 0.32 ± 0.27 dB/cm and 2.04 ± 0.65 dB/cm at 7.5 MHz, depending on the amount of carnauba wax added to the base material. The materials do not suffer dehydration and provide adequate needle penetration, with a Young's storage modulus varying between 14.7 ± 0.2 kPa and 34.9 ± 0.3 kPa. The phantom background material possesses long-term stability and can be employed in a supine position without changes in geometry. These results indicate that paraffin-gel waxes may be promising materials for training radiologists in ultrasound biopsy procedures. Copyright © 2013 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  15. MR guided FUS therapy with a Robotic Assistance System

    NASA Astrophysics Data System (ADS)

    Jenne, Jürgen W.; Krafft, Axel J.; Maier, Florian; Rauschenberg, Jaane; Semmler, Wolfhard; Huber, Peter E.; Bock, Michael

    2009-04-01

    Magnetic Resonance imaging guided Focus Ultrasound Surgery (MRgFUS) is a highly precise method to ablate tissue non-invasively. To date, there is only one commercial MRgFUS system available and only a few are in a prototype stage. The objective of this ongoing project is to establish an MRgFUS therapy unit as add-on for a commercially available robotic assistance system originally designed for percutaneous needle interventions in whole-body MR scanners.

  16. Use of Electromagnetic Navigational Transthoracic Needle Aspiration (E-TTNA) for Sampling of Lung Nodules.

    PubMed

    Arias, Sixto; Lee, Hans; Semaan, Roy; Frimpong, Bernice; Ortiz, Ricardo; Feller-Kopman, David; Oakjones-Burgess, Karen; Yarmus, Lonny

    2015-05-23

    Lung nodule evaluation represents a clinical challenge especially in patients with intermediate risk for malignancy. Multiple technologies are presently available to sample nodules for pathological diagnosis. Those technologies can be divided into bronchoscopic and non-bronchoscopic interventions. Electromagnetic navigational bronchoscopy is being extensively used for the endobronchial approach to peripheral lung nodules but has been hindered by anatomic challenges resulting in a 70% diagnostic yield. Electromagnetic navigational guided transthoracic needle lung biopsy is novel non-bronchoscopic method that uses a percutaneous electromagnetic tip tracked needle to obtain core biopsy specimens. Electromagnetic navigational transthoracic needle aspiration complements bronchoscopic techniques potentially allowing the provider to maximize the diagnostic yield during one single procedure. This article describes a novel integrated diagnostic approach to pulmonary lung nodules. We propose the use of endobronchial ultrasound transbronchial needle aspiration (EBUS-TBNA) for mediastinal staging; radial EBUS, navigational bronchoscopy and E-TTNA during one single procedure to maximize diagnostic yield and minimize the number of invasive procedures needed to obtain a diagnosis. This manuscript describes in detail how the navigation transthoracic procedure is performed. Additional clinical studies are needed to determine the clinical utility of this novel technology.

  17. Multifunctional Catheters Combining Intracardiac Ultrasound Imaging and Electrophysiology Sensing

    PubMed Central

    Stephens, Douglas N.; Cannata, Jonathan; Liu, Ruibin; Zhao, Jian Zhong; Shung, K. Kirk; Nguyen, Hien; Chia, Raymond; Dentinger, Aaron; Wildes, Douglas; Thomenius, Kai E.; Mahajan, Aman; Shivkumar, Kalyanam; Kim, Kang; O’Donnell, Matthew; Nikoozadeh, Amin; Oralkan, Omer; Khuri-Yakub, Pierre T.; Sahn, David J.

    2015-01-01

    A family of 3 multifunctional intracardiac imaging and electrophysiology (EP) mapping catheters has been in development to help guide diagnostic and therapeutic intracardiac EP procedures. The catheter tip on the first device includes a 7.5 MHz, 64-element, side-looking phased array for high resolution sector scanning. The second device is a forward-looking catheter with a 24-element 14 MHz phased array. Both of these catheters operate on a commercial imaging system with standard software. Multiple EP mapping sensors were mounted as ring electrodes near the arrays for electrocardiographic synchronization of ultrasound images and used for unique integration with EP mapping technologies. To help establish the catheters’ ability for integration with EP interventional procedures, tests were performed in vivo in a porcine animal model to demonstrate both useful intracardiac echocardiographic (ICE) visualization and simultaneous 3-D positional information using integrated electroanatomical mapping techniques. The catheters also performed well in high frame rate imaging, color flow imaging, and strain rate imaging of atrial and ventricular structures. The companion paper of this work discusses the catheter design of the side-looking catheter with special attention to acoustic lens design. The third device in development is a 10 MHz forward-looking ring array that is to be mounted at the distal tip of a 9F catheter to permit use of the available catheter lumen for adjunctive therapy tools. PMID:18986948

  18. Multifunctional catheters combining intracardiac ultrasound imaging and electrophysiology sensing.

    PubMed

    Stephens, D N; Cannata, J; Liu, Ruibin; Zhao, Jian Zhong; Shung, K K; Nguyen, Hien; Chia, R; Dentinger, A; Wildes, D; Thomenius, K E; Mahajan, A; Shivkumar, K; Kim, Kang; O'Donnell, M; Nikoozadeh, A; Oralkan, O; Khuri-Yakub, P T; Sahn, D J

    2008-07-01

    A family of 3 multifunctional intracardiac imaging and electrophysiology (EP) mapping catheters has been in development to help guide diagnostic and therapeutic intracardiac EP procedures. The catheter tip on the first device includes a 7.5 MHz, 64-element, side-looking phased array for high resolution sector scanning. The second device is a forward-looking catheter with a 24-element 14 MHz phased array. Both of these catheters operate on a commercial imaging system with standard software. Multiple EP mapping sensors were mounted as ring electrodes near the arrays for electrocardiographic synchronization of ultrasound images and used for unique integration with EP mapping technologies. To help establish the catheters' ability for integration with EP interventional procedures, tests were performed in vivo in a porcine animal model to demonstrate both useful intracardiac echocardiographic (ICE) visualization and simultaneous 3-D positional information using integrated electroanatomical mapping techniques. The catheters also performed well in high frame rate imaging, color flow imaging, and strain rate imaging of atrial and ventricular structures. The companion paper of this work discusses the catheter design of the side-looking catheter with special attention to acoustic lens design. The third device in development is a 10 MHz forward-looking ring array that is to be mounted at the distal tip of a 9F catheter to permit use of the available catheter lumen for adjunctive therapy tools.

  19. Image-guided tumor ablation: standardization of terminology and reporting criteria.

    PubMed

    Goldberg, S Nahum; Grassi, Clement J; Cardella, John F; Charboneau, J William; Dodd, Gerald D; Dupuy, Damian E; Gervais, Debra A; Gillams, Alice R; Kane, Robert A; Lee, Fred T; Livraghi, Tito; McGahan, John; Phillips, David A; Rhim, Hyunchul; Silverman, Stuart G; Solbiati, Luigi; Vogl, Thomas J; Wood, Bradford J; Vedantham, Suresh; Sacks, David

    2009-07-01

    The field of interventional oncology with use of image-guided tumor ablation requires standardization of terminology and reporting criteria to facilitate effective communication of ideas and appropriate comparison between treatments that use different technologies, such as chemical (ethanol or acetic acid) ablation, and thermal therapies, such as radiofrequency (RF), laser, microwave, ultrasound, and cryoablation. This document provides a framework that will hopefully facilitate the clearest communication between investigators and will provide the greatest flexibility in comparison between the many new, exciting, and emerging technologies. An appropriate vehicle for reporting the various aspects of image-guided ablation therapy, including classification of therapies and procedure terms, appropriate descriptors of imaging guidance, and terminology to define imaging and pathologic findings, are outlined. Methods for standardizing the reporting of follow-up findings and complications and other important aspects that require attention when reporting clinical results are addressed. It is the group's intention that adherence to the recommendations will facilitate achievement of the group's main objective: improved precision and communication in this field that lead to more accurate comparison of technologies and results and, ultimately, to improved patient outcomes. The intent of this standardization of terminology is to provide an appropriate vehicle for reporting the various aspects of image-guided ablation therapy.

  20. Tracheobronchial puncture-site nodular reaction (TPNR) following endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA): Systematic review of case reports.

    PubMed

    Madan, Karan; Tiwari, Pavan; Arava, Sudheer; Hadda, Vijay; Mohan, Anant; Guleria, Randeep

    2017-01-01

    Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a minimally invasive and efficacious diagnostic modality for lung cancer staging and evaluation of undiagnosed mediastinal lymphadenopathy. Procedure-related complications are uncommon. We herein report an infrequently described phenomenon following EBUS-TBNA in which two patients developed nodular granulation tissue at the tracheobronchial puncture site. On systematic review, we found description of such phenomena by terminologies such as endobronchial inflammatory polyp, granuloma, and endobronchial mass. The endobronchial inflammatory polyp has been one of the most commonly used terminologies for these; but in most cases, the classical features of an inflammatory polyp are lacking. We propose the term, tracheobronchial puncture-site nodular reaction (TPNR) with further classification into granulomatous and nongranulomatous subtypes, for standardized reporting of such reactions following transbronchial needle aspiration procedures. Knowledge of this entity and standardized nomenclature shall help in better characterization of the outcomes and risk factors for the occurrence of these reactions.

  1. Comparison of microbubble presence in the right heart during mechanochemical and radiofrequency ablation for varicose veins.

    PubMed

    Moon, K H; Dharmarajah, B; Bootun, R; Lim, C S; Lane, Tra; Moore, H M; Sritharan, K; Davies, A H

    2017-07-01

    Objective Mechanochemical ablation is a novel technique for ablation of varicose veins utilising a rotating catheter and liquid sclerosant. Mechanochemical ablation and radiofrequency ablation have no reported neurological side-effect but the rotating mechanism of mechanochemical ablation may produce microbubbles. Air emboli have been implicated as a cause of cerebrovascular events during ultrasound-guided foam sclerotherapy and microbubbles in the heart during ultrasound-guided foam sclerotherapy have been demonstrated. This study investigated the presence of microbubbles in the right heart during varicose vein ablation by mechanochemical abaltion and radiofrequency abaltion. Methods Patients undergoing great saphenous vein ablation by mechanochemical abaltion or radiofrequency ablation were recruited. During the ablative procedure, the presence of microbubbles was assessed using transthoracic echocardiogram. Offline blinded image quantification was performed using International Consensus Criteria grading guidelines. Results From 32 recruited patients, 28 data sets were analysed. Eleven underwent mechanochemical abaltion and 17 underwent radiofrequency abaltion. There were no neurological complications. In total, 39% (11/28) of patients had grade 1 or 2 microbubbles detected. Thirty-six percent (4/11) of mechanochemical abaltion patients and 29% (5/17) of radiofrequency ablation patients had microbubbles with no significant difference between the groups ( p=0.8065). Conclusion A comparable prevalence of microbubbles between mechanochemical abaltion and radiofrequency ablation both of which are lower than that previously reported for ultrasound-guided foam sclerotherapy suggests that mechanochemical abaltion may not confer the same risk of neurological events as ultrasound-guided foam sclerotherapy for treatment of varicose veins.

  2. Feasibility of contrast-enhanced ultrasound-guided biopsy of sentinel lymph nodes in dogs.

    PubMed

    Gelb, Hylton R; Freeman, Lynetta J; Rohleder, Jacob J; Snyder, Paul W

    2010-01-01

    Our goal was to develop and validate a technique to identify the sentinel lymph nodes of the mammary glands of healthy dogs with contrast-enhanced ultrasound, and evaluate the feasibility of obtaining representative samples of a sentinel lymph node under ultrasound guidance using a new biopsy device. Three healthy intact female adult hounds were anesthetized and each received an injection of octafluoropropane-filled lipid microspheres and a separate subcutaneous injection of methylene blue dye around a mammary gland. Ultrasound was then used to follow the contrast agent through the lymphatic channel to the sentinel lymph node. Lymph node biopsy was performed under ultrasound guidance, followed by an excisional biopsy of the lymph nodes and a regional mastectomy procedure. Excised tissues were submitted for histopathologic examination and evaluated as to whether they were representative of the node. The ultrasound contrast agent was easily visualized with ultrasound leading up to the sentinel lymph nodes. Eight normal lymph nodes (two inguinal, one axillary in two dogs; two inguinal in one dog) were identified and biopsied. Lymphoid tissue was obtained from all biopsy specimens. Samples from four of eight lymph nodes contained both cortical and medullary lymphoid tissue. Contrast-enhanced ultrasound can be successfully used to image and guide minimally invasive biopsy of the normal sentinel lymph nodes draining the mammary glands in healthy dogs. Further work is needed to evaluate whether this technique may be applicable in patients with breast cancer or other conditions warranting evaluation of sentinel lymph nodes in animals.

  3. Ultrasound-guided pleural access.

    PubMed

    Shojaee, Samira; Argento, A Christine

    2014-12-01

    Ultrasonography of the thorax has become a more recognized tool in pulmonary medicine, thanks to continuing clinical research that has proven its many valuable roles in the day-to-day management of pulmonary and pleural diseases. Ultrasound examination is a cost-effective imaging modality that permits the pulmonologist to obtain information about the pathologies in the thorax without the risk of exposure to ionizing radiation, providing the examiner with real-time and immediate results. Its ease of use and training along with its portability to the patient's bedside and accurate examination of the pleural space has allowed for safer pleural procedures such as thoracentesis, chest tube placement, tunneled pleural catheter placement, and medical thoracoscopy. In this review, we summarize the technique of chest ultrasonography, compare ultrasound to other frequently used thoracic imaging modalities, and focus on its use in obtaining pleural access while performing invasive pleural procedures. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  4. Ultrasound-Guided Carpal Tunnel Release Using Dynamic Expansion of the Transverse Safe Zone in a Patient With Postpolio Syndrome: A Case Report.

    PubMed

    Henning, Troy; Lueders, Daniel; Chang, Kate; Yang, Lynda

    2018-03-06

    The prevalence of carpal tunnel syndrome (CTS) in patients with postpolio syndrome occurs at a rate of 22%. Irrespective of those with CTS, 74% of postpolio patients weight bear through their arms for ambulation or transfers. As open carpal tunnel release is performed along the weight-bearing region of the wrist, their functional independence may be altered while recovering. This case demonstrates that ultrasound-guided carpal tunnel release was successfully performed in a patient with postpolio syndrome allowing him to immediately weight bear through his hands after the procedure so he could recover at home. Copyright © 2018 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  5. Ultrasound guided V3 segment vertebral artery direct percutaneous puncture for basilar artery mechanical thrombectomy in acute stroke: a technical report.

    PubMed

    Desai, Jamsheed A; Almekhlafi, Mohammed A; Hill, Michael D; Goyal, Mayank; Eesa, Muneer

    2014-04-01

    A middle aged patient presented with acute ischemic stroke due to basilar artery occlusion. The patient clinically deteriorated despite intravenous thrombolysis and was referred for mechanical thrombectomy. The right vertebral artery was occluded and could not be accessed despite attempting various shaped catheters, even when a radial artery access was used. The left vertebral artery ended in the posterior inferior cerebellar artery. Eventually, ultrasound guided V3 segment vertebral artery direct puncture was successfully done and the procedure was completed. No access related complications were encountered. Direct cervical arterial puncture can be safely used by experienced operators as a last resort in acute stroke cases with difficult access.

  6. First-in-human experience using the Volcano VIBE-RX vascular imaging balloon catheter system (Volcano IVUS-guided Balloon Evaluation - New Zealand: VIBE-NZ Study).

    PubMed

    Watson, Timothy; El-Jack, Seifeddin; Stewart, James T; Ormiston, John

    2013-09-01

    Intravascular ultrasound (IVUS) is a proven and safe imaging modality used to guide percutaneous coronary intervention (PCI). The Volcano VIBE™ RX Vascular Imaging Balloon Catheter is a novel rapid exchange, 0.014" wire-compatible multi-lumen conventional balloon catheter modified with the addition of an IVUS transducer proximal to the balloon, delivered via a standard 6 Fr sheath. We sought to evaluate the safety, balloon performance, and image quality of the VIBE™ RX in patients scheduled for coronary intervention. Patients aged >21 and <85 years with single or multivessel coronary disease scheduled for PCI due to coronary ischaemic symptoms were included. Those with angiographic features that precluded the safe or informative use of the device were excluded. Twenty-nine patients having angiography because of ischaemic symptoms underwent 44 VIBE RX imaging runs, with balloon dilation in 20. Successful device deployment was achieved in all but one patient. All images were adequate and reproducible. One patient had a non-ST-elevation MI felt to be due to the complexity of the procedure rather than directly related to the VIBE™ RX. The study demonstrated the safety and effectiveness of the VIBE™ RX for its intended purpose with minimal failure rate and no directly related complications.

  7. Real-time needle guidance with photoacoustic and laser-generated ultrasound probes

    NASA Astrophysics Data System (ADS)

    Colchester, Richard J.; Mosse, Charles A.; Nikitichev, Daniil I.; Zhang, Edward Z.; West, Simeon; Beard, Paul C.; Papakonstantinou, Ioannis; Desjardins, Adrien E.

    2015-03-01

    Detection of tissue structures such as nerves and blood vessels is of critical importance during many needle-based minimally invasive procedures. For instance, unintentional injections into arteries can lead to strokes or cardiotoxicity during interventional pain management procedures that involve injections in the vicinity of nerves. Reliable detection with current external imaging systems remains elusive. Optical generation and reception of ultrasound allow for depth-resolved sensing and they can be performed with optical fibers that are positioned within needles used in clinical practice. The needle probe developed in this study comprised separate optical fibers for generating and receiving ultrasound. Photoacoustic generation of ultrasound was performed on the distal end face of an optical fiber by coating it with an optically absorbing material. Ultrasound reception was performed using a high-finesse Fabry-Pérot cavity. The sensor data was displayed as an M-mode image with a real-time interface. Imaging was performed on a biological tissue phantom.

  8. Ultrasound-guided medical thoracoscopy in the absence of pleural effusion.

    PubMed

    Marchetti, Giampietro; Valsecchi, Alberto; Indellicati, Davide; Arondi, Sabrina; Trigiani, Marco; Pinelli, Valentina

    2015-04-01

    Medical thoracoscopy (MT) is a diagnostic and therapeutic procedure that permits the study of the pleural space. The presence of pleural adhesions is the most important contraindication to performing MT. Lesions of the pleura in absence of pleural effusion are usually studied in video-assisted thoracoscopic surgery (VATS) with preoperative ultrasound evaluation. No data are available about ultrasound-guided MT in the absence of pleural effusion. From January 2007 to June 2013, 622 consecutive MTs were performed under ultrasound guidance without inducing a pneumothorax. A retrospective cohort of 29 patients affected by pleural diseases without fluid was reviewed. The fifth or sixth intercostal spaces along the midaxillary line with a good echographic "sliding sign" and normal appearance of the pleural line were chosen as the entry site. The pleural cavity was explored, and biopsies were performed. The mean age of the patient cohort was 62.8 years; there were 20 male patients and nine female patients. Pleural adherences were avoided, and adequate number of pleural biopsies were performed. No parenchymal lung injuries, bleeding, or hematoma occurred. Seventeen patients had a completely free pleural cavity, four patients had a single pleural adhesion, and eight had multiple pleural adhesions; in all cases, however, endoscopic exploration was possible and biopsy specimens were adequate. The most frequent histopathologic diagnosis was malignant pleural mesothelioma. We have shown that thoracic ultrasound accurately identifies intrathoracic adhesions and, in experienced hands, can guide MT access, replacing the VATS approach, even in the complete absence of pleural effusion.

  9. PET/CT-guided interventions: Indications, advantages, disadvantages and the state of the art.

    PubMed

    Cazzato, Roberto Luigi; Garnon, Julien; Shaygi, Behnam; Koch, Guillaume; Tsoumakidou, Georgia; Caudrelier, Jean; Addeo, Pietro; Bachellier, Philippe; Namer, Izzie Jacques; Gangi, Afshin

    2018-02-01

    Positron emission tomography/computed tomography (PET/CT) represents an emerging imaging guidance modality that has been applied to successfully guide percutaneous procedures such as biopsies and tumour ablations. The aim of the present narrative review is to report the indications, advantages and disadvantages of PET/CT-guided procedures in the field of interventional oncology and to briefly describe the experience gained with this new emerging technique while performing biopsies and tumor ablations.

  10. A long arm for ultrasound: a combined robotic focused ultrasound setup for magnetic resonance-guided focused ultrasound surgery.

    PubMed

    Krafft, Axel J; Jenne, Jürgen W; Maier, Florian; Stafford, R Jason; Huber, Peter E; Semmler, Wolfhard; Bock, Michael

    2010-05-01

    Focused ultrasound surgery (FUS) is a highly precise noninvasive procedure to ablate pathogenic tissue. FUS therapy is often combined with magnetic resonance (MR) imaging as MR imaging offers excellent target identification and allows for continuous monitoring of FUS induced temperature changes. As the dimensions of the ultrasound (US) focus are typically much smaller than the targeted volume, multiple sonications and focus repositioning are interleaved to scan the focus over the target volume. Focal scanning can be achieved electronically by using phased-array US transducers or mechanically by using dedicated mechanical actuators. In this study, the authors propose and evaluate the precision of a combined robotic FUS setup to overcome some of the limitations of the existing MRgFUS systems. Such systems are typically integrated into the patient table of the MR scanner and thus only provide an application of the US wave within a limited spatial range from below the patient. The fully MR-compatible robotic assistance system InnoMotion (InnoMedic GmbH, Herxheim, Germany) was originally designed for MR-guided interventions with needles. It offers five pneumatically driven degrees of freedom and can be moved over a wide range within the bore of the magnet. In this work, the robotic system was combined with a fixed-focus US transducer (frequency: 1.7 MHz; focal length: 68 mm, and numerical aperture: 0.44) that was integrated into a dedicated, in-house developed treatment unit for FUS application. A series of MR-guided focal scanning procedures was performed in a polyacrylamide-egg white gel phantom to assess the positioning accuracy of the combined FUS setup. In animal experiments with a 3-month-old domestic pig, the system's potential and suitability for MRgFUS was tested. In phantom experiments, a total targeting precision of about 3 mm was found, which is comparable to that of the existing MRgFUS systems. Focus positioning could be performed within a few seconds. During in vivo experiments, a defined pattern of single thermal lesions and a therapeutically relevant confluent thermal lesion could be created. The creation of local tissue necrosis by coagulation was confirmed by post-FUS MR imaging and histological examinations on the treated tissue sample. During all sonications in phantom and in vivo, reliable MR imaging and online MR thermometry could be performed without compromises due to operation of the combined robotic FUS setup. Compared to the existing MRgFUS systems, the combined robotic FUS approach offers a wide range of spatial flexibility so that highly flexible application of the US wave would be possible, for example, to avoid risk structures within the US field. The setup might help to realize new ways of patient access in MRgFUS therapy. The setup is compatible with any closed-bore MR system and does not require an especially designed patient table.

  11. Magnetic resonance image guided transurethral ultrasound prostate ablation: a preclinical safety and feasibility study with 28-day followup.

    PubMed

    Burtnyk, Mathieu; Hill, Tracy; Cadieux-Pitre, Heather; Welch, Ian

    2015-05-01

    We determine the safety and feasibility of magnetic resonance image guided transurethral ultrasound prostate ablation using active temperature feedback control in a preclinical canine model with 28-day followup. After a long acclimatization period we performed ultrasound treatment in 8 subjects using the magnetic resonance image guided TULSA-PRO™ transurethral ultrasound prostate ablation system. Comprehensive examinations and observations were done before and throughout the 28-day followup, including assessment of clinically significant treatment related adverse events. In addition to gross pathology evaluation, extensive histopathological analysis was done to assess cell kill inside and outside the prostate. We evaluated prostate conformal heating by comparing the spatial difference between the treatment plan and the 55C isotherm measured on magnetic resonance imaging thermometry acquired during treatment. These findings were confirmed on contrast enhanced magnetic resonance imaging immediately after treatment and at 28 days. Clinically there were no adverse events in any of the 8 subjects throughout the 28-day followup. All subjects had normal urinary and bowel function. Gross necropsy and histology confirmed that the intended thermal cell kill was confined to the prostate. No surrounding tissue was damaged, including the rectum and the external urinary sphincter. Conformal heating was achieved with an average -0.9 mm accuracy and 0.9 mm precision. Contrast enhanced magnetic resonance imaging and histological analysis confirmed tissue ablation in targeted areas of the prostate. Urethral tissue was spared from thermal damage. Magnetic resonance image guided transurethral ultrasound is a safe, feasible procedure for accurate and precise conformal thermal ablation of prostate tissue, as demonstrated in a preclinical model with 28-day followup. Copyright © 2015 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  12. Fluoroscopy-assisted vs fluoroless endoscopic ultrasound-guided transmural drainage of pancreatic fluid collections: A comparative study.

    PubMed

    Consiglieri, Claudia F; Gornals, Joan B; Busquets, Juli; Peláez, Nuria; Secanella, Lluis; De-La-Hera, Meritxell; Sanzol, Resurrección; Fabregat, Joan; Castellote, José

    2018-01-01

    The need for fluoroscopy guidance in patients undergoing endoscopic ultrasound-guided transmural drainage (EUS-TMD) of peripancreatic fluid collections (PFCs) remains unclear. The aim of this study was to compare general outcomes of EUS-TMD of PFCs under fluoroscopy (F) vs fluoroless (FL). This is a comparative study with a retrospective analysis of a prospective and consecutive inclusion database at a tertiary centre, from 2009 to 2015. All patients were symptomatic pseudocyst (PSC) and walled-off pancreatic necrosis (WON). Two groups were assigned depending on availability of fluoroscopy. The groups were heterogeneous in terms of their demographic characteristics, PFCs and procedure. The main outcome measures included technical and clinical success, incidences, adverse events (AEs), and follow-up. Fifty EUS-TMD of PFCs from 86 EUS-guided drainages were included during the study period. Group F included 26 procedures, PSC 69.2%, WON 30.8%, metal stents 61.5% (46.1% lumen-apposing stent) and plastic stents 38.5%. Group FL included 24 procedures, PSC 37.5%, WON 62.5%, and metal stents 95.8% (lumen-apposing stents). Technical success was 100% in both groups, and clinical success was similar (F 88.5%, FL 87.5%). Technical incidences and intra-procedure AEs were only described in group F (7.6% and 11.5%, respectively) and none in group FL. Procedure time was less in group FL (8min, p=0.0341). Fluoroless in the EUS-TMD of PFCs does not involve more technical incidences or intra-procedure AEs. Technical and clinical success was similar in the two groups. Copyright © 2017 Elsevier España, S.L.U. All rights reserved.

  13. The Agreement between Auscultation and Lung Ultrasound in Hemodialysis Patients: The LUST Study

    PubMed Central

    Torino, Claudia; Gargani, Luna; Sicari, Rosa; Letachowicz, Krzysztof; Ekart, Robert; Fliser, Danilo; Covic, Adrian; Siamopoulos, Kostas; Stavroulopoulos, Aristeidis; Massy, Ziad A.; Fiaccadori, Enrico; Caiazza, Alberto; Bachelet, Thomas; Slotki, Itzchak; Martinez-Castelao, Alberto; Coudert-Krier, Marie-Jeanne; Rossignol, Patrick; Gueler, Faikah; Hannedouche, Thierry; Panichi, Vincenzo; Wiecek, Andrzej; Pontoriero, Giuseppe; Sarafidis, Pantelis; Klinger, Marian; Hojs, Radovan; Seiler-Mussler, Sarah; Lizzi, Fabio; Siriopol, Dimitrie; Balafa, Olga; Shavit, Linda; Tripepi, Rocco; Mallamaci, Francesca; Tripepi, Giovanni; Picano, Eugenio; London, Gérard Michel

    2016-01-01

    Background and objectives Accumulation of fluid in the lung is the most concerning sequela of volume expansion in patients with ESRD. Lung auscultation is recommended to detect and monitor pulmonary congestion, but its reliability in ESRD is unknown. Design, setting, participants, & measurements In a subproject of the ongoing Lung Water by Ultra-Sound Guided Treatment to Prevent Death and Cardiovascular Complications in High Risk ESRD Patients with Cardiomyopathy Trial, we compared a lung ultrasound–guided ultrafiltration prescription policy versus standard care in high-risk patients on hemodialysis. The reliability of peripheral edema was tested as well. This study was on the basis of 1106 pre– and postdialysis lung ultrasound studies (in 79 patients) simultaneous with standardized lung auscultation (crackles at the lung bases) and quantification of peripheral edema. Results Lung congestion by crackles, edema, or a combination thereof poorly reflected the severity of congestion as detected by ultrasound B lines in various analyses, including standard regression analysis weighting for repeated measures in individual patients (shared variance of 12% and 4% for crackles and edema, respectively) and κ-statistics (κ ranging from 0.00 to 0.16). In general, auscultation had very low discriminatory power for the diagnosis of mild (area under the receiver operating curve =0.61), moderate (area under the receiver operating curve =0.65), and severe (area under the receiver operating curve =0.68) lung congestion, and the same was true for peripheral edema (receiver operating curve =0.56 or lower) and the combination of the two physical signs. Conclusions Lung crackles, either alone or combined with peripheral edema, very poorly reflect interstitial lung edema in patients with ESRD. These findings reinforce the rationale underlying the Lung Water by Ultra-Sound Guided Treatment to Prevent Death and Cardiovascular Complications in High Risk ESRD Patients with Cardiomyopathy Trial, a trial adopting ultrasound B lines as an instrument to guide interventions aimed at mitigating lung congestion in high-risk patients on hemodialysis. PMID:27660305

  14. Peripherally Inserted Central Catheter Placement with the Sonic Flashlight: Initial Clinical Trial by Nurses

    PubMed Central

    Wang, David; Amesur, Nikhil; Shukla, Gaurav; Bayless, Angela; Weiser, David; Scharl, Adam; Mockel, Derek; Banks, Christopher; Mandella, Bernadette; Klatzky, Roberta; Stetten, George

    2010-01-01

    Objective We describe a case series comprising the first clinical trial by intravenous (IV) team nurses using the Sonic Flashlight for ultrasound guidance of peripherally inserted central catheter (PICC) placement. Methods Two IV team nurses with more than 10 years experience placing PICCs and from 3–6 years experience with ultrasound (US) attempted to place PICCs under US guidance in patients requiring long-term IV access. One of two methods of US guidance was used: conventional ultrasound (CUS) (60 patients) or a new device called the Sonic Flashlight (SF) (44 patients). The number of needle punctures required to gain IV access was recorded for each subject. Results In both methods, 87% of the cases resulted in successful venous access on the first attempt. The average number of needle sticks per patient was 1.18 for SF-guided procedures, as compared to 1.20 for CUS-guided procedures. No significant difference was found in the distribution of the number of attempts between the two methods. Anecdotal comments by the nurses indicated the comparative ease of use of the SF display, although relatively small scale of the SF image compared to the CUS image was also noted. Conclusions We have shown that the Sonic Flashlight is a safe and effective device for guidance of PICC placement in the hands of experienced IV team nurses. The advantage of placing the ultrasound image at its actual location must be balanced against the relatively small scale of the SF image. PMID:19389904

  15. Improved image guidance technique for minimally invasive mitral valve repair using real-time tracked 3D ultrasound

    NASA Astrophysics Data System (ADS)

    Rankin, Adam; Moore, John; Bainbridge, Daniel; Peters, Terry

    2016-03-01

    In the past ten years, numerous new surgical and interventional techniques have been developed for treating heart valve disease without the need for cardiopulmonary bypass. Heart valve repair is now being performed in a blood-filled environment, reinforcing the need for accurate and intuitive imaging techniques. Previous work has demonstrated how augmenting ultrasound with virtual representations of specific anatomical landmarks can greatly simplify interventional navigation challenges and increase patient safety. These techniques often complicate interventions by requiring additional steps taken to manually define and initialize virtual models. Furthermore, overlaying virtual elements into real-time image data can also obstruct the view of salient image information. To address these limitations, a system was developed that uses real-time volumetric ultrasound alongside magnetically tracked tools presented in an augmented virtuality environment to provide a streamlined navigation guidance platform. In phantom studies simulating a beating-heart navigation task, procedure duration and tool path metrics have achieved comparable performance to previous work in augmented virtuality techniques, and considerable improvement over standard of care ultrasound guidance.

  16. WE-EF-210-08: BEST IN PHYSICS (IMAGING): 3D Prostate Segmentation in Ultrasound Images Using Patch-Based Anatomical Feature

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, X; Rossi, P; Jani, A

    Purpose: Transrectal ultrasound (TRUS) is the standard imaging modality for the image-guided prostate-cancer interventions (e.g., biopsy and brachytherapy) due to its versatility and real-time capability. Accurate segmentation of the prostate plays a key role in biopsy needle placement, treatment planning, and motion monitoring. As ultrasound images have a relatively low signal-to-noise ratio (SNR), automatic segmentation of the prostate is difficult. However, manual segmentation during biopsy or radiation therapy can be time consuming. We are developing an automated method to address this technical challenge. Methods: The proposed segmentation method consists of two major stages: the training stage and the segmentation stage.more » During the training stage, patch-based anatomical features are extracted from the registered training images with patient-specific information, because these training images have been mapped to the new patient’ images, and the more informative anatomical features are selected to train the kernel support vector machine (KSVM). During the segmentation stage, the selected anatomical features are extracted from newly acquired image as the input of the well-trained KSVM and the output of this trained KSVM is the segmented prostate of this patient. Results: This segmentation technique was validated with a clinical study of 10 patients. The accuracy of our approach was assessed using the manual segmentation. The mean volume Dice Overlap Coefficient was 89.7±2.3%, and the average surface distance was 1.52 ± 0.57 mm between our and manual segmentation, which indicate that the automatic segmentation method works well and could be used for 3D ultrasound-guided prostate intervention. Conclusion: We have developed a new prostate segmentation approach based on the optimal feature learning framework, demonstrated its clinical feasibility, and validated its accuracy with manual segmentation (gold standard). This segmentation technique could be a useful tool for image-guided interventions in prostate-cancer diagnosis and treatment. This research is supported in part by DOD PCRP Award W81XWH-13-1-0269, and National Cancer Institute (NCI) Grant CA114313.« less

  17. Reality named endoscopic ultrasound biliary drainage

    PubMed Central

    Guedes, Hugo Gonçalo; Lopes, Roberto Iglesias; de Oliveira, Joel Fernandez; Artifon, Everson Luiz de Almeida

    2015-01-01

    Endoscopic ultrasound (EUS) is used for diagnosis and evaluation of many diseases of the gastrointestinal (GI) tract. In the past, it was used to guide a cholangiography, but nowadays it emerges as a powerful therapeutic tool in biliary drainage. The aims of this review are: outline the rationale for endoscopic ultrasound-guided biliary drainage (EGBD); detail the procedural technique; evaluate the clinical outcomes and limitations of the method; and provide recommendations for the practicing clinician. In cases of failed endoscopic retrograde cholangiopancreatography (ERCP), patients are usually referred for either percutaneous transhepatic biliary drainage (PTBD) or surgical bypass. Both these procedures have high rates of undesirable complications. EGBD is an attractive alternative to PTBD or surgery when ERCP fails. EGBD can be performed at two locations: transhepatic or extrahepatic, and the stent can be inserted in an antegrade or retrograde fashion. The drainage route can be transluminal, duodenal or transpapillary, which, again, can be antegrade or retrograde [rendezvous (EUS-RV)]. Complications of all techniques combined include pneumoperitoneum, bleeding, bile leak/peritonitis and cholangitis. We recommend EGBD when bile duct access is not possible because of failed cannulation, altered upper GI tract anatomy, gastric outlet obstruction, a distorted ampulla or a periampullary diverticulum, as a minimally invasive alternative to surgery or radiology. PMID:26504507

  18. The EFSUMB website, a great source for ultrasound information and education.

    PubMed

    Dietrich, Christoph F; Rudd, Lynne; Saftiou, Adrian; Gilja, Odd Helge

    2017-01-31

    The aim of this updated EFSUMB-website guide is to introduce readers to EFSUMB's wide ranging activities. The most recent are the guidelines on interventional ultrasound and intestinal ultrasound and updated CEUS Non-Liver and Elastography Liver Guidelines which can be freely downloaded. Hosting eBooks on our website is another new departure, most importantly the EFSUMB Course Book on Ultrasound available in a second edition as an eReader and an online Student Edition of the ECB. EFSUMB has been active with updating Guidelines; those mentioned above have all been revised or written in thelast two years. Webinars have been introduced and participation is possible online but can be reviewed later along with recent recordings of Euroson Schools. The EFSUMB Newsletter in the EJU promotes our activities and topical articles intended to reach all our members with the online version hosted on our website. The Case of the Month continues to be one of EFSUMB's most visited sites and in the last few years has been translated into 14 different languages including Chinese. In conclusion, this article aims to provide an updated guide to the website educational sites of the European Federation of Societies for Ultrasound in Medicine and Biology (EFSUMB).

  19. Patient-specific 3D printing simulation to guide complex coronary intervention.

    PubMed

    Oliveira-Santos, Manuel; Oliveira Santos, Eduardo; Marinho, Ana Vera; Leite, Luís; Guardado, Jorge; Matos, Vítor; Pego, Guilherme Mariano; Marques, João Silva

    2018-05-07

    The field of three-dimensional printing applied to patient-specific simulation is evolving as a tool to enhance intervention results. We report the first case of a fully simulated percutaneous coronary intervention in a three-dimensional patient-specific model to guide treatment. An 85-year-old female presented with symptomatic in-stent restenosis in the ostial circumflex and was scheduled for percutaneous coronary intervention. Considering the complexity of the anatomy, patient setting and intervention technique, we elected to replicate the coronary anatomy using a three-dimensional model. In this way, we simulated the intervention procedure beforehand in the catheterization laboratory using standard materials. The procedure was guided by optical coherence tomography, with pre-dilatation of the lesion, implantation of a single drug-eluting stent in the ostial circumflex and kissing balloon inflation to the left anterior descending artery and circumflex. Procedural steps were replicated in the real patient's treatment, with remarkable parallelism in angiographic outcome and luminal gain at intracoronary imaging. In this proof-of-concept report, we show that patient-specific simulation is feasible to guide the treatment strategy of complex coronary artery disease. It enables the surgical team to plan and practice the procedure beforehand, and possibly predict complications and gain confidence. Copyright © 2018 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  20. Ultrasound guided double injection of blood into cisterna magna: a rabbit model for treatment of cerebral vasospasm.

    PubMed

    Chen, Yongchao; Zhu, Youzhi; Zhang, Yu; Zhang, Zixuan; Lian, Juan; Luo, Fucheng; Deng, Xuefei; Wong, Kelvin K L

    2016-02-06

    Double injection of blood into cisterna magna using a rabbit model results in cerebral vasospasm. An unacceptably high mortality rate tends to limit the application of model. Ultrasound guided puncture can provide real-time imaging guidance for operation. The aim of this paper is to establish a safe and effective rabbit model of cerebral vasospasm after subarachnoid hemorrhage with the assistance of ultrasound medical imaging. A total of 160 New Zealand white rabbits were randomly divided into four groups of 40 each: (1) manual control group, (2) manual model group, (3) ultrasound guided control group, and (4) ultrasound guided model group. The subarachnoid hemorrhage was intentionally caused by double injection of blood into their cisterna magna. Then, basilar artery diameters were measured using magnetic resonance angiography before modeling and 5 days after modeling. The depth of needle entering into cisterna magna was determined during the process of ultrasound guided puncture. The mortality rates in manual control group and model group were 15 and 23 %, respectively. No rabbits were sacrificed in those two ultrasound guided groups. We found that the mortality rate in ultrasound guided groups decreased significantly compared to manual groups. Compared with diameters before modeling, the basilar artery diameters after modeling were significantly lower in manual and ultrasound guided model groups. The vasospasm aggravated and the proportion of severe vasospasms was greater in ultrasound guided model group than that of manual group. In manual model group, no vasospasm was found in 8 % of rabbits. The ultrasound guided double injection of blood into cisterna magna is a safe and effective rabbit model for treatment of cerebral vasospasm.

  1. A Fresh Cadaver Model for the Instruction of Ultrasound-Guided Fine-Needle Aspiration of Thyroid Nodules.

    PubMed

    McCrary, Hilary C; Faucett, Erynne A; Hurbon, Audriana N; Milinic, Tijana; Cervantes, Jose A; Kent, Sean L; Adamas-Rappaport, William J

    2017-07-01

    Objective The aim of our study is to determine if a fresh cadaver model (FCM) for the instruction of ultrasound (US)-guided fine-needle aspiration (FNA) of thyroid nodules is a practical method for instruction. Study Design Pre- and postinstruction assessment of medical students' ability to perform US-guided FNA of artificially created thyroid nodules placed adjacent to the thyroid gland of a fresh cadaver. Setting University-based fresh cadaver laboratory. Subjects and Methods Study participants included a total of 17 first- and second-year medical students with minimal US training. Technical skills were assessed using a 10-item checklist. In addition, a cognitive assessment regarding the indications, contraindications, and complications of the procedure was completed. A postinstruction assessment was provided for participants 5 weeks after their initial assessment. Differences between pre- and postinstruction assessment scores of technical skills were analyzed using McNemar's test. The mean cognitive knowledge gain was analyzed using a paired 2-sample t test. Results Eight of 10 items on the skills checklist were statistically significant between pre- and postinstruction skills assessment ( P < .05). There was a statistically significant change in cognitive knowledge gain regarding the contraindications of the procedure ( P = .001), but not for indications or complications ( P = .104 and P = .111, respectively). Conclusion US-guided FNA continues to be an important diagnostic procedure in the workup of thyroid nodules, making it an essential skill to integrate into surgical skills lab. Our FCM for the instruction of US-guided FNA is the first of its kind, and this pilot study shows this is a viable method for instruction.

  2. Mini-STAR as bail-out strategy for percutaneous coronary intervention of chronic total occlusion.

    PubMed

    Galassi, Alfredo Ruggero; Tomasello, Salvatore Davide; Costanzo, Luca; Campisano, Maria Barbara; Barrano, Giombattista; Ueno, Masafumi; Tello-Montoliu, Antonio; Tamburino, Corrado

    2012-01-01

    Although the advancement of the equipment and the presence of innovative techniques, percutaneous coronary intervention (PCI) for chronic total occlusion (CTO) continues to be affected by lower procedural success in comparison with non occluded vessel PCI. We describe a new technique for the treatment of coronary CTO which utilizes a new generation of polymeric wires. From March 2009 to June 2010 different strategies were adopted as "bail out" after an initial attempt failed in 117 consecutive CTO lesions. Among these, conventional strategies (CS) such as parallel wire, sub-intimal tracking and re-entry (STAR), microchannel technique, intracoronary ultrasound guided revascularization and anchor balloon, were used in 75 cases (64.1%), while in the remaining a new technique, the "mini-STAR," was used (39.9%). Although no substantial differences were observed regarding the distribution of clinical features and angiographic lesions characteristics between the populations, mini-STAR was able to achieve a higher rate of procedural success in comparison with other CS (97.6% vs. 52%, P < 0.001) with lower contrast agent use (442 ± 259 cm(3) vs. 561 ± 243 cm(3), P = 0.01) and shorter procedural and fluoroscopy times (122 ± 61 vs. 157 ± 74 min, P = 0.009 and 60 ± 31 min vs. 75 ± 38 min, P = 0.03, respectively). No differences were observed in term of peri-procedural complications such as procedural myocardial infarction, coronary perforations, and contrast-induced nephropathy between mini-STAR and CS. The mini-STAR technique is a promising strategy for the treatment of CTO lesions, achieving a high procedural success rate and low occurrence of procedural adverse events. Copyright © 2011 Wiley Periodicals, Inc.

  3. Ultrasound-guided intervention in the ankle and foot

    PubMed Central

    Allen, Gina M; Watura, Roland

    2016-01-01

    In this comprehensive review, we discuss the main interventions performed in the foot and ankle for Achilles tendinopathy, Morton's neuromas and Plantar fasciitis as well as techniques for intra-articular and peritendinous injections. We present the different imaging techniques and injectable agents that can be used in clinical practice, trying to help the reader decide the most appropriate way of managing the patient with a problem in the ankle and foot. PMID:26537692

  4. A novel procedure employing laser ultrasound technique and simplex algorism for the characterization of mechanical and geometrical properties in Zircaloy tubes with different levels of hydrogen charging

    NASA Astrophysics Data System (ADS)

    Liu, I.-Hung; Yang, Che-Hua

    2011-01-01

    In this research, a procedure employing a laser ultrasound technique (LUT) and an inversion algorism is reported for nondestructive characterization of mechanical and geometrical properties in Zircaloy tubes with different levels of hydrogen charging. With the LUT, guided acoustic waves are generated to propagate in the Zircaloy tubes and are detected remotely by optical means. By measuring the dispersive wavespeeds followed by the inversion algorism, mechanical properties such as elastic moduli and geometrical property such as wall-thickness of Zircaloy tubes are characterized for different levels of hydrogen charging. Having the advantages of remote, non-contact and point-wise generation/detection, the reported procedure serves as a competitive candidate for the characterization of Zircaloy tubes generally operated in irradiative and temperature-elevated environments.

  5. CT Scan-Guided Abrams' Needle Pleural Biopsy versus Ultrasound-Assisted Cutting Needle Pleural Biopsy for Diagnosis in Patients with Pleural Effusion: A Randomized, Controlled Trial.

    PubMed

    Metintas, Muzaffer; Yildirim, Huseyin; Kaya, Tamer; Ak, Guntulu; Dundar, Emine; Ozkan, Ragip; Metintas, Selma

    2016-01-01

    Image-guided pleural biopsies, both using ultrasound (US) or computed tomography (CT), are important in the diagnosis of pleural disease. However, no consensus exists regarding which biopsy needles are appropriate for specific procedures. In this randomized, prospective study, we aimed to compare CT scan-guided pleural biopsy using an Abrams' needle (CT-ANPB) with US-assisted pleural biopsy using a cutting needle (US-CNPB) with respect to both diagnostic yield and safety. Between February 2009 and April 2013, 150 patients with exudative pleural effusion who could not be diagnosed by cytological analysis were included in the study. The patients were randomized into either the US-CNPB group or the CT-ANPB group. The two groups were compared in terms of diagnostic sensitivity and complications. Of the 150 patients enrolled in this study, 45 were diagnosed with malignant mesothelioma, 46 were diagnosed with metastatic pleural disease, 18 were diagnosed with pleural tuberculosis, 34 were diagnosed with benign pleural disease, and 7 were lost to follow-up. In the US-CNPB group, the diagnostic sensitivity was 66.7%, compared with 82.4% in the CT-ANPB group; the difference between the two groups was statistically significant (p = 0.029). The sensitivity of CT-ANPB increased to 93.7% for patients with a pleural thickness ≥1 cm. The complication rates were low and acceptable. The first diagnostic intervention that should be preferred in patients with pleural effusion and associated pleural thickening on a CT scan is CT-ANPB. US-CNPB should be used primarily in cases for which only pleural thickening but no pleural effusion is noted. © 2016 S. Karger AG, Basel.

  6. High-intensity focused ultrasound treatment in refractory glaucoma patients: results at 1 year of prospective clinical study.

    PubMed

    Melamed, Shlomo; Goldenfeld, Modi; Cotlear, Daniel; Skaat, Alon; Moroz, Iris

    2015-01-01

    To evaluate the safety and efficacy of the ultrasonic circular cyclo-coagulation procedure using high-intensity focused ultrasound by a miniaturized annular device containing 6 piezoceramic transducers in patients with refractory glaucoma. This was a prospective interventional noncomparative study of 20 eyes of 20 patients with refractory glaucoma. All eyes were treated with 6 activated transducers operating at 21 MHz. Ultrasound biomicroscopy and a complete ophthalmic examination were performed before the procedure and at 1 day, 1 week, and 1, 3, 6, and 12 months after the procedure. Primary outcomes were surgical success (defined as intraocular pressure (IOP) reduction from baseline ≥20% and IOP >5 mm Hg) at the last follow-up visit. Secondary outcomes were mean IOP at each follow-up visit compared to baseline, medication use, complications, and re-interventions. Intraocular pressure was significantly reduced (p<0.01) from a mean preoperative value of 36.4 ± 5.7 mm Hg to a mean postoperative value of 22.5 ± 10.3 mm Hg at 12 months. Four patients needed to be re-treated. The mean IOP reduction achieved was 38%. Surgical success was achieved in 13 of 20 eyes (65%). No major intraoperative or postoperative complications occurred. Ultrasonic circular cyclo-coagulation using high-intensity focused ultrasound delivered by a circular miniaturized device containing 6 piezoceramic transducers is an effective and well-tolerated method to reduce IOP in patients with refractory glaucoma.

  7. Non-Invasive Targeted Peripheral Nerve Ablation Using 3D MR Neurography and MRI-Guided High-Intensity Focused Ultrasound (MR-HIFU): Pilot Study in a Swine Model.

    PubMed

    Huisman, Merel; Staruch, Robert M; Ladouceur-Wodzak, Michelle; van den Bosch, Maurice A; Burns, Dennis K; Chhabra, Avneesh; Chopra, Rajiv

    2015-01-01

    Ultrasound (US)-guided high intensity focused ultrasound (HIFU) has been proposed for noninvasive treatment of neuropathic pain and has been investigated in in-vivo studies. However, ultrasound has important limitations regarding treatment guidance and temperature monitoring. Magnetic resonance (MR)-imaging guidance may overcome these limitations and MR-guided HIFU (MR-HIFU) has been used successfully for other clinical indications. The primary purpose of this study was to evaluate the feasibility of utilizing 3D MR neurography to identify and guide ablation of peripheral nerves using a clinical MR-HIFU system. Volumetric MR-HIFU was used to induce lesions in the peripheral nerves of the lower limbs in three pigs. Diffusion-prep MR neurography and T1-weighted images were utilized to identify the target, plan treatment and immediate post-treatment evaluation. For each treatment, one 8 or 12 mm diameter treatment cell was used (sonication duration 20 s and 36 s, power 160-300 W). Peripheral nerves were extracted < 3 hours after treatment. Ablation dimensions were calculated from thermal maps, post-contrast MRI and macroscopy. Histological analysis included standard H&E staining, Masson's trichrome and toluidine blue staining. All targeted peripheral nerves were identifiable on MR neurography and T1-weighted images and could be accurately ablated with a single exposure of focused ultrasound, with peak temperatures of 60.3 to 85.7°C. The lesion dimensions as measured on MR neurography were similar to the lesion dimensions as measured on CE-T1, thermal dose maps, and macroscopy. Histology indicated major hyperacute peripheral nerve damage, mostly confined to the location targeted for ablation. Our preliminary results indicate that targeted peripheral nerve ablation is feasible with MR-HIFU. Diffusion-prep 3D MR neurography has potential for guiding therapy procedures where either nerve targeting or avoidance is desired, and may also have potential for post-treatment verification of thermal lesions without contrast injection.

  8. Pain related to robotic cholecystectomy with lower abdominal ports: effect of the bilateral ultrasound-guided split injection technique of rectus sheath block in female patients

    PubMed Central

    Kim, Jin Soo; Choi, Jong Bum; Lee, Sook Young; Kim, Wook Hwan; Baek, Nam Hyun; Kim, Jayoun; Park, Chu Kyung; Lee, Yeon Ju; Park, Sung Yong

    2016-01-01

    Abstract Background: Robotic cholecystectomy (RC) using port sites in the lower abdominal area (T12-L1) rather than the upper abdomen has recently been introduced as an alternative procedure for laparoscopic cholecystectomy. Therefore, we investigated the time course of different components of pain and the analgesic effect of the bilateral ultrasound-guided split injection technique for rectus sheath block (sRSB) after RC in female patients. Methods: We randomly assigned 40 patients to undergo ultrasound-guided sRSB (RSB group, n = 20) or to not undergo any block (control group, n = 20). Pain was subdivided into 3 components: superficial wound pain, deep abdominal pain, and referred shoulder pain, which were evaluated with a numeric rating scale (from 0 to 10) at baseline (time of awakening) and at 1, 6, 9, and 24 hours postoperatively. Consumption of fentanyl and general satisfaction were also evaluated 1 hour (before discharge from the postanesthesia care unit) and 24 hours postoperatively (end of study). Results: Superficial wound pain was predominant only at awakening, and after postoperative 1 hour in the control group. Bilateral ultrasound-guided sRSB significantly decreased superficial pain after RC (P < 0.01) and resulted in a better satisfaction score (P < 0.05) 1 hour after RC in the RSB group compared with the control group. The cumulative postoperative consumption of fentanyl at 6, 9, and 24 hours was not significantly different between groups. Conclusions: After RC with lower abdominal ports, superficial wound pain predominates over deep intra-abdominal pain and shoulder pain only at the time of awakening. Afterwards, superficial and deep pain decreased to insignificant levels in 6 hours. Bilateral ultrasound-guided sRSB was effective only during the first hour. This limited benefit should be balanced against the time and risks entailed in performing RSB. PMID:27495072

  9. Pain related to robotic cholecystectomy with lower abdominal ports: effect of the bilateral ultrasound-guided split injection technique of rectus sheath block in female patients: A prospective randomised trial.

    PubMed

    Kim, Jin Soo; Choi, Jong Bum; Lee, Sook Young; Kim, Wook Hwan; Baek, Nam Hyun; Kim, Jayoun; Park, Chu Kyung; Lee, Yeon Ju; Park, Sung Yong

    2016-08-01

    Robotic cholecystectomy (RC) using port sites in the lower abdominal area (T12-L1) rather than the upper abdomen has recently been introduced as an alternative procedure for laparoscopic cholecystectomy. Therefore, we investigated the time course of different components of pain and the analgesic effect of the bilateral ultrasound-guided split injection technique for rectus sheath block (sRSB) after RC in female patients. We randomly assigned 40 patients to undergo ultrasound-guided sRSB (RSB group, n = 20) or to not undergo any block (control group, n = 20). Pain was subdivided into 3 components: superficial wound pain, deep abdominal pain, and referred shoulder pain, which were evaluated with a numeric rating scale (from 0 to 10) at baseline (time of awakening) and at 1, 6, 9, and 24 hours postoperatively. Consumption of fentanyl and general satisfaction were also evaluated 1 hour (before discharge from the postanesthesia care unit) and 24 hours postoperatively (end of study). Superficial wound pain was predominant only at awakening, and after postoperative 1 hour in the control group. Bilateral ultrasound-guided sRSB significantly decreased superficial pain after RC (P < 0.01) and resulted in a better satisfaction score (P < 0.05) 1 hour after RC in the RSB group compared with the control group. The cumulative postoperative consumption of fentanyl at 6, 9, and 24 hours was not significantly different between groups. After RC with lower abdominal ports, superficial wound pain predominates over deep intra-abdominal pain and shoulder pain only at the time of awakening. Afterwards, superficial and deep pain decreased to insignificant levels in 6 hours. Bilateral ultrasound-guided sRSB was effective only during the first hour. This limited benefit should be balanced against the time and risks entailed in performing RSB.

  10. Endoscopic surgery and telemedicine in microgravity: developing contingency procedures for exploratory class spaceflight.

    PubMed

    Jones, J A; Johnston, S; Campbell, M; Miles, B; Billica, R

    1999-05-01

    The risk of a urinary calculus during an extended duration mission into the reduced gravity environment of space is significant. For medical operations to develop a comprehensive strategy for the spaceflight stone risk, both preventive countermeasures and contingency management (CM) plans must be included. A feasibility study was conducted to demonstrate the potential CM technique of endoscopic ureteral stenting with ultrasound guidance for the possible in-flight urinary calculus contingency. The procedure employed the International Space Station/Human Research Facility ultrasound unit for guide wire and stent localization, a flexible cystoscope for visual guidance, and banded, biocompatible soft ureteral stents to successfully stent porcine ureters bilaterally in zero gravity (0g). The study demonstrated that downlinked endoscopic surgical and ultrasound images obtained in 0g are comparable in quality to 1g images, and therefore are useful for diagnostic clinical utility via telemedicine transmission. In order to be successful, surgical procedures in 0g require excellent positional stability of the operating surgeon, assistant, and patient, relative to one another. The technological development of medical procedures for long-duration spaceflight contingencies may lead to improved terrestrial patient care methodology and subsequently reduced morbidity.

  11. Endoscopic surgery and telemedicine in microgravity: developing contingency procedures for exploratory class spaceflight

    NASA Technical Reports Server (NTRS)

    Jones, J. A.; Johnston, S.; Campbell, M.; Miles, B.; Billica, R.

    1999-01-01

    OBJECTIVES: The risk of a urinary calculus during an extended duration mission into the reduced gravity environment of space is significant. For medical operations to develop a comprehensive strategy for the spaceflight stone risk, both preventive countermeasures and contingency management (CM) plans must be included. METHODS: A feasibility study was conducted to demonstrate the potential CM technique of endoscopic ureteral stenting with ultrasound guidance for the possible in-flight urinary calculus contingency. The procedure employed the International Space Station/Human Research Facility ultrasound unit for guide wire and stent localization, a flexible cystoscope for visual guidance, and banded, biocompatible soft ureteral stents to successfully stent porcine ureters bilaterally in zero gravity (0g). RESULTS: The study demonstrated that downlinked endoscopic surgical and ultrasound images obtained in 0g are comparable in quality to 1g images, and therefore are useful for diagnostic clinical utility via telemedicine transmission. CONCLUSIONS: In order to be successful, surgical procedures in 0g require excellent positional stability of the operating surgeon, assistant, and patient, relative to one another. The technological development of medical procedures for long-duration spaceflight contingencies may lead to improved terrestrial patient care methodology and subsequently reduced morbidity.

  12. Ultrasound-guided trans-rectal high-intensity focused ultrasound (HIFU) for advanced cervical cancer ablation is feasible: a case report.

    PubMed

    Abel, M; Ahmed, H; Leen, E; Park, E; Chen, M; Wasan, H; Price, P; Monzon, L; Gedroyc, W; Abel, P

    2015-01-01

    High-intensity focused ultrasound (HIFU) is an ablative treatment undergoing assessment for the treatment of benign and malignant disease. We describe the first reported intracavitary HIFU ablation for recurrent, unresectable and symptomatic cervical cancer. A 38 year old woman receiving palliative chemotherapy for metastatic cervical adenocarcinoma was offered ablative treatment from an intracavitary trans-rectal HIFU device (Sonablate® 500). Pre-treatment symptoms included vaginal bleeding and discharge that were sufficient to impede her quality of life. No peri-procedural adverse events occurred. Symptoms resolved completely immediately post-procedure, reappeared at 7 days, increasing to pre-procedural levels by day 30. This first time experience of intracavitary cervical HIFU suggests that it is feasible for palliation of advanced cervical cancer, with no early evidence of unexpected toxicity. Ethical approval had also been granted for the use of per-vaginal access if appropriate. This route, alone or in combination with the rectal route, may provide increased accessibility in future patients with a redesigned device more suited to trans-vaginal ablations. Intracavitary HIFU is a potentially safe procedure for the treatment of cervical cancer and able to provide symptomatic improvement in the palliative setting.

  13. Power cavitation-guided blood-brain barrier opening with focused ultrasound and microbubbles

    NASA Astrophysics Data System (ADS)

    Burgess, M. T.; Apostolakis, I.; Konofagou, E. E.

    2018-03-01

    Image-guided monitoring of microbubble-based focused ultrasound (FUS) therapies relies on the accurate localization of FUS-stimulated microbubble activity (i.e. acoustic cavitation). Passive cavitation imaging with ultrasound arrays can achieve this, but with insufficient spatial resolution. In this study, we address this limitation and perform high-resolution monitoring of acoustic cavitation-mediated blood-brain barrier (BBB) opening with a new technique called power cavitation imaging. By synchronizing the FUS transmit and passive receive acquisition, high-resolution passive cavitation imaging was achieved by using delay and sum beamforming with absolute time delays. Since the axial image resolution is now dependent on the duration of the received acoustic cavitation emission, short pulses of FUS were used to limit its duration. Image sets were acquired at high-frame rates for calculation of power cavitation images analogous to power Doppler imaging. Power cavitation imaging displays the mean intensity of acoustic cavitation over time and was correlated with areas of acoustic cavitation-induced BBB opening. Power cavitation-guided BBB opening with FUS could constitute a standalone system that may not require MRI guidance during the procedure. The same technique can be used for other acoustic cavitation-based FUS therapies, for both safety and guidance.

  14. Power cavitation-guided blood-brain barrier opening with focused ultrasound and microbubbles.

    PubMed

    Burgess, M T; Apostolakis, I; Konofagou, E E

    2018-03-15

    Image-guided monitoring of microbubble-based focused ultrasound (FUS) therapies relies on the accurate localization of FUS-stimulated microbubble activity (i.e. acoustic cavitation). Passive cavitation imaging with ultrasound arrays can achieve this, but with insufficient spatial resolution. In this study, we address this limitation and perform high-resolution monitoring of acoustic cavitation-mediated blood-brain barrier (BBB) opening with a new technique called power cavitation imaging. By synchronizing the FUS transmit and passive receive acquisition, high-resolution passive cavitation imaging was achieved by using delay and sum beamforming with absolute time delays. Since the axial image resolution is now dependent on the duration of the received acoustic cavitation emission, short pulses of FUS were used to limit its duration. Image sets were acquired at high-frame rates for calculation of power cavitation images analogous to power Doppler imaging. Power cavitation imaging displays the mean intensity of acoustic cavitation over time and was correlated with areas of acoustic cavitation-induced BBB opening. Power cavitation-guided BBB opening with FUS could constitute a standalone system that may not require MRI guidance during the procedure. The same technique can be used for other acoustic cavitation-based FUS therapies, for both safety and guidance.

  15. Integration of stereotactic ultrasonic data into an interactive image-guided neurosurgical system

    NASA Astrophysics Data System (ADS)

    Shima, Daniel W.; Galloway, Robert L., Jr.

    1998-06-01

    Stereotactic ultrasound can be incorporated into an interactive, image-guide neurosurgical system by using an optical position sensor to define the location of an intraoperative scanner in physical space. A C-program has been developed that communicates with the OptotrakTM system developed by Northern Digital Inc. to optically track the three-dimensional position and orientation of a fan-shaped area defined with respect to a hand-held probe. (i.e., a virtual B-mode ultrasound fan beam) Volumes of CT and MR head scans from the same patient are registered to a location in physical space using a point-based technique. The coordinates of the virtual fan beam in physical space are continuously calculated and updated on-the-fly. During each program loop, the CT and MR data volumes are reformatted along the same plane and displayed as two fan-shaped images that correspond to the current physical-space location of the virtual fan beam. When the reformatted preoperative tomographic images are eventually paired with a real-time intraoperative ultrasound image, a neurosurgeon will be able to use the unique information of each imaging modality (e.g., the high resolution and tissue contrast of CT and MR and the real-time functionality of ultrasound) in a complementary manner to identify structures in the brain more easily and to guide surgical procedures more effectively.

  16. Ultrasound: medical imaging and beyond (an invited review).

    PubMed

    Azhari, Haim

    2012-09-01

    Medical applications of ultrasound were first investigated about seventy years ago. It has rapidly evolved since then, becoming an essential tool in medical imaging. Ultrasound ability to provide real time images with frame rates exceeding several hundred frames per second allows one to view rapid anatomical changes as well as to guide minimal invasive procedures. By, combining Doppler techniques with anatomical images ultrasound provides real time quantitative flow information as well. It is portable, versatile, cost effective and considered sufficiently hazardless to monitor pregnancy. Moreover, ultrasound has the unique capacity to offer therapeutic capabilities in addition to its outstanding imaging abilities. It can be used for physiotherapy, lithotripsy, and thermal ablation, and recent studies have demonstrated its usefulness in drug delivery, gene therapy and molecular imaging. The purpose of this article is to provide an introductory review of the field covering briefly topics from basic physics through current imaging methods to therapeutic applications.

  17. Versatile robotic probe calibration for position tracking in ultrasound imaging.

    PubMed

    Bø, Lars Eirik; Hofstad, Erlend Fagertun; Lindseth, Frank; Hernes, Toril A N

    2015-05-07

    Within the field of ultrasound-guided procedures, there are a number of methods for ultrasound probe calibration. While these methods are usually developed for a specific probe, they are in principle easily adapted to other probes. In practice, however, the adaptation often proves tedious and this is impractical in a research setting, where new probes are tested regularly. Therefore, we developed a method which can be applied to a large variety of probes without adaptation. The method used a robot arm to move a plastic sphere submerged in water through the ultrasound image plane, providing a slow and precise movement. The sphere was then segmented from the recorded ultrasound images using a MATLAB programme and the calibration matrix was computed based on this segmentation in combination with tracking information. The method was tested on three very different probes demonstrating both great versatility and high accuracy.

  18. Versatile robotic probe calibration for position tracking in ultrasound imaging

    NASA Astrophysics Data System (ADS)

    Eirik Bø, Lars; Fagertun Hofstad, Erlend; Lindseth, Frank; Hernes, Toril A. N.

    2015-05-01

    Within the field of ultrasound-guided procedures, there are a number of methods for ultrasound probe calibration. While these methods are usually developed for a specific probe, they are in principle easily adapted to other probes. In practice, however, the adaptation often proves tedious and this is impractical in a research setting, where new probes are tested regularly. Therefore, we developed a method which can be applied to a large variety of probes without adaptation. The method used a robot arm to move a plastic sphere submerged in water through the ultrasound image plane, providing a slow and precise movement. The sphere was then segmented from the recorded ultrasound images using a MATLAB programme and the calibration matrix was computed based on this segmentation in combination with tracking information. The method was tested on three very different probes demonstrating both great versatility and high accuracy.

  19. Ultrasound-Guided Transesophageal High-Intensity Focused Ultrasound Cardiac Ablation in a Beating Heart: A Pilot Feasibility Study in Pigs.

    PubMed

    Bessiere, Francis; N'djin, W Apoutou; Colas, Elodie Constanciel; Chavrier, Françoise; Greillier, Paul; Chapelon, Jean Yves; Chevalier, Philippe; Lafon, Cyril

    2016-08-01

    Catheter ablation for the treatment of arrhythmia is associated with significant complications and often-repeated procedures. Consequently, a less invasive and more efficient technique is required. Because high-intensity focused ultrasound (HIFU) enables the generation of precise thermal ablations in deep-seated tissues without harming the tissues in the propagation path, it has the potential to be used as a new ablation technique. A system capable of delivering HIFU into the heart by a transesophageal route using ultrasound (US) imaging guidance was developed and tested in vivo in six male pigs. HIFU exposures were performed on atria and ventricles. At the time of autopsy, visual inspection identified thermal lesions in the targeted areas in three of the animals. These lesions were confirmed by histologic analysis (mean size: 5.5 mm(2) × 11 mm(2)). No esophageal thermal injury was observed. One animal presented with bradycardia due to an atrio-ventricular block, which provides real-time confirmation of an interaction between HIFU and the electrical circuits of the heart. Thus, US-guided HIFU has the potential to minimally invasively create myocardial lesions without an intra-cardiac device. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  20. MR-guided prostate interventions.

    PubMed

    Tempany, Clare; Straus, Sarah; Hata, Nobuhiko; Haker, Steven

    2008-02-01

    In this article the current issues of diagnosis and detection of prostate cancer are reviewed. The limitations for current techniques are highlighted and some possible solutions with MR imaging and MR-guided biopsy approaches are reviewed. There are several different biopsy approaches under investigation. These include transperineal open magnet approaches to closed-bore 1.5T transrectal biopsies. The imaging, image processing, and tracking methods are also discussed. In the arena of therapy, MR guidance has been used in conjunction with radiation methods, either brachytherapy or external delivery. The principles of the radiation treatment, the toxicities, and use of images are outlined. The future role of imaging and image-guided interventions lie with providing a noninvasive surrogate for cancer surveillance or monitoring treatment response. The shift to minimally invasive focal therapies has already begun and will be very exciting when MR-guided focused ultrasound surgery reaches its full potential. (Copyright) 2008 Wiley-Liss, Inc.

  1. MR-Guided Prostate Interventions

    PubMed Central

    Tempany, Clare; Straus, Sarah; Hata, Nobuhiko; Haker, Steven

    2009-01-01

    In this article the current issues of diagnosis and detection of prostate cancer are reviewed. The limitations for current techniques are highlighted and some possible solutions with MR imaging and MR-guided biopsy approaches are reviewed. There are several different biopsy approaches under investigation. These include transperineal open magnet approaches to closed-bore 1.5T transrectal biopsies. The imaging, image processing, and tracking methods are also discussed. In the arena of therapy, MR guidance has been used in conjunction with radiation methods, either brachytherapy or external delivery. The principles of the radiation treatment, the toxicities, and use of images are outlined. The future role of imaging and image-guided interventions lie with providing a noninvasive surrogate for cancer surveillance or monitoring treatment response. The shift to minimally invasive focal therapies has already begun and will be very exciting when MR-guided focused ultrasound surgery reaches its full potential. PMID:18219689

  2. Minimal invasive complete excision of benign breast tumors using a three-dimensional ultrasound-guided mammotome vacuum device.

    PubMed

    Baez, E; Huber, A; Vetter, M; Hackelöer, B-J

    2003-03-01

    The aim of this study was to evaluate the use of three-dimensional (3D) ultrasonography in the complete excision of benign breast tumors using ultrasound-guided vacuum-assisted core-needle biopsy (Mammotome). A protocol for the management of benign breast tumors is proposed. Twenty consecutive patients with sonographically benign breast lesions underwent 3D ultrasound-guided mammotome biopsy under local anesthesia. The indication for surgical biopsy was a solid lesion with benign characteristics on both two-dimensional (2D) and 3D ultrasound imaging, increasing in size over time or causing pain or irritation. Preoperatively, the size of the lesion was assessed using 2D and 3D volumetry. During vacuum biopsy the needle was visualized sonographically in all three dimensions, including the coronal plane. Excisional biopsy was considered complete when no residual tumor tissue could be seen sonographically. Ultrasonographic follow-up examinations were performed on the following day and 3-6 months later to assess residual tissue and scarring. All lesions were histologically benign. Follow-up examinations revealed complete excision of all lesions of < 1.5 mL in volume as assessed by 3D volumetry. 3D ultrasonographic volume assessment was more accurate than 2D using the ellipsoid formula or assessment of the maximum diameter for the prediction of complete excision of the tumor. No bleeding or infections occurred postoperatively and no scarring was seen ultrasonographically on follow-up examinations. Ultrasound-guided vacuum-assisted biopsy allows complete excision of benign breast lesions that are

  3. Novel Image-Guided Management of a Uterine Arteriovenous Malformation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Przybojewski, Stefan J., E-mail: drstefanp@hotmail.com; Sadler, David J.

    The investigators present a novel image-guided embolization, not previously described, of a uterine arteriovenous malformation (AVM) resistant to endovascular management. The uterus was exposed surgically, and Histoacryl (Braun, Fulda, Germany) was injected directly into the nidus using ultrasound guidance and fluoroscopy. The patient had a successful full-term pregnancy after this procedure. This technique may be a useful alternative management strategy in patients with uterine AVM who fail traditional endovascular embolization and who still desire fertility.

  4. Successful Treatment of Abdominal Cutaneous Entrapment Syndrome Using Ultrasound Guided Injection

    PubMed Central

    Hong, Myong Joo; Seo, Dong Hyuk

    2013-01-01

    There are various origins for chronic abdominal pain. About 10-30% of patients with chronic abdominal pain have abdominal wall pain. Unfortunately, abdominal wall pain is not thought to be the first origin of chronic abdominal pain; therefore, patients usually undergo extensive examinations, including diagnostic laparoscopic surgery. Entrapment of abdominal cutaneous nerves at the muscular foramen of the rectus abdominis is a rare cause of abdominal wall pain. If abdominal wall pain is considered in earlier stage of chronic abdominal pain, unnecessary invasive procedures are not required and patients will reach symptom free condition as soon as the diagnosis is made. Here, we report a case of successful treatment of a patient with abdominal cutaneous nerve entrapment syndrome by ultrasound guided injection therapy. PMID:23862004

  5. Effect of using different U/S probe Standoff materials in image geometry for interventional procedures: the example of prostate

    PubMed Central

    Diamantopoulos, Stefanos; Butt, Saeed; Katsilieri, Zaira; Kefala, Vasiliki; Zogal, Pawel; Sakas, George; Baltas, Dimos

    2011-01-01

    Purpose This study investigates the distortion of geometry of catheters and anatomy in acquired U/S images, caused by utilizing various stand-off materials for covering a transrectal bi-planar ultrasound probe in HDR and LDR prostate brachytherapy, biopsy and other interventional procedures. Furthermore, an evaluation of currently established water-bath based quality assurance (QA) procedures is presented. Material and methods Image acquisitions of an ultrasound QA setup were carried out at 5 MHz and 7 MHz. The U/S probe was covered by EA 4015 Silicone Standoff kit, or UA0059 Endocavity balloon filled either with water or one of the following: 40 ml of Endosgel®, Instillagel®, Ultraschall gel or Space OAR™ gel. The differences between images were recorded. Consequently, the dosimetric impact of the observed image distortion was investigated, using a tissue equivalent ultrasound prostate phantom – Model number 053 (CIRS Inc., Norfolk, VA, USA). Results By using the EA 4015 Silicone Standoff kit in normal water with sound speed of 1525 m/s, a 3 mm needle shift was observed. The expansion of objects appeared in radial direction. The shift deforms also the PTV (prostate in our case) and other organs at risk (OARs) in the same way leading to overestimation of volume and underestimation of the dose. On the other hand, Instillagel® and Space OAR™ “shrinks” objects in an ultrasound image for 0.65 mm and 0.40 mm, respectively. Conclusions The use of EA 4015 Silicone Standoff kit for image acquisition, leads to erroneous contouring of PTV and OARs and reconstruction and placement of catheters, which results to incorrect dose calculation during prostate brachytherapy. Moreover, the reliability of QA procedures lies mostly in the right temperature of the water used for accurate simulation of real conditions of transrectal ultrasound imaging. PMID:23346130

  6. A review of randomised controlled trials comparing ultrasound-guided foam sclerotherapy with endothermal ablation for the treatment of great saphenous varicose veins.

    PubMed

    Davies, Huw Ob; Popplewell, Matthew; Darvall, Katy; Bate, Gareth; Bradbury, Andrew W

    2016-05-01

    The last 10 years have seen the introduction into everyday clinical practice of a wide range of novel non-surgical treatments for varicose veins. In July 2013, the UK National Institute for Health and Care Excellence recommended the following treatment hierarchy for varicose veins: endothermal ablation, ultrasound-guided foam sclerotherapy, surgery and compression hosiery. The aim of this paper is to review the randomised controlled trials that have compared endothermal ablation and ultrasound-guided foam sclerotherapy to determine if the level 1 evidence base still supports an "endothermal ablation first" strategy for the treatment of varicose veins. A PubMed and OVID literature search (until 31 January 2015) was performed and randomised controlled trials comparing endothermal ablation and ultrasound-guided foam sclerotherapy were obtained. Although anatomical success appeared higher with endothermal ablation than ultrasound-guided foam sclerotherapy, clinical success and patient-reported outcomes measures were similar. Morbidity and complication rates were very low and not significantly different between endothermal ablation and ultrasound-guided foam sclerotherapy. Ultrasound-guided foam sclerotherapy was consistently less expensive that endothermal ablation. All endovenous modalities appear to be successful and have a role in modern day practice. Although further work is required to optimise ultrasound-guided foam sclerotherapy technique to maximise anatomical success and minimise retreatment, the present level 1 evidence base shows there is no significant difference in clinical important outcomes between ultrasound-guided foam sclerotherapy and endothermal ablation. As ultrasound-guided foam sclerotherapy is less expensive, it is likely to be a more cost-effective option in most patients in most healthcare settings. Strict adherence to the treatment hierarchy recommended by National Institute for Health and Care Excellence seems unjustified. © The Author(s) 2015.

  7. A combined hands-on teaching programme and clinical pathway focused on pleural ultrasound and procedure supervision transforms pleural procedure outcomes.

    PubMed

    Edwards, Timothy; Cook, Alistair; Salamonsen, Matthew; Bashirzadeh, Farzad; Fielding, David

    2017-11-01

    Management of pleural effusions is a common diagnostic and management problem. We reviewed the outcomes from pleural procedures after the instigation of pleural effusion management guidelines, focusing on pleural ultrasound and a hands-on teaching programme followed by procedure supervision that enabled many operators to perform such procedures. This is a retrospective analysis of all procedures performed for pleural effusions on medical patients. Outcomes were assessed prior to the instigation of pleural effusion management guidelines (pleural pathway) and hands-on teaching (January 2010 to June 2011) and following these interventions (January 2012 to June 2013). A total of 171 procedures involving 129 patients (pre-pathway group) and 146 procedures involving 115 patients (post-pathway group) was analysed. The rate of complications prior to the pleural pathway was 22.2% (38 of 171 procedures). Following the pathway, the rate of complications declined to 7.5% (11 of 146 procedures, P < 0.003). The use of pleural ultrasound increased dramatically (72.5 vs 90.2%). The number of patients who underwent repeated procedures (defined as ≥3) reduced dramatically (21 vs 7, P < 0.01). This improvement occurred using many supervised operators who completed the hands-on teaching programme (n = 32) and followed the pleural pathway (127 of 146 procedures). The instigation of a clinical pathway focused on the use of bedside pleural ultrasound, and teaching of drainage techniques with procedure supervision vastly improved patient outcomes. This not only allowed better quality of care for patients, it also provided the acquisition of new skills to medical staff, not limiting these skills to specialised staff. © 2017 Royal Australasian College of Physicians.

  8. Greater trochanteric pain syndrome diagnosis and treatment.

    PubMed

    Mallow, Michael; Nazarian, Levon N

    2014-05-01

    Lateral hip pain, or greater trochanteric pain syndrome, is a commonly seen condition; in this article, the relevant anatomy, epidemiology, and evaluation strategies of greater trochanteric pain syndrome are reviewed. Specific attention is focused on imaging of this syndrome and treatment techniques, including ultrasound-guided interventions. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. Ottawa County Writing Process Model for PPO Assessments.

    ERIC Educational Resources Information Center

    Ottawa County Office of Education, OH.

    This guide outlines the writing procedures for English Composition Pupil Performance Objective (PPO) assessments and tests. Procedures for both students and teachers are included for the prewriting, first draft writing, and revising/rewriting sessions. A brief guide to evaluation procedures and intervention strategies is also provided. (MM)

  10. Real-time ultrasound-guided catheterisation of the internal jugular vein: a prospective comparison with the landmark technique in critical care patients

    PubMed Central

    Karakitsos, Dimitrios; Labropoulos, Nicolaos; De Groot, Eric; Patrianakos, Alexandros P; Kouraklis, Gregorios; Poularas, John; Samonis, George; Tsoutsos, Dimosthenis A; Konstadoulakis, Manousos M; Karabinis, Andreas

    2006-01-01

    Introduction Central venous cannulation is crucial in the management of the critical care patient. This study was designed to evaluate whether real-time ultrasound-guided cannulation of the internal jugular vein is superior to the standard landmark method. Methods In this randomised study, 450 critical care patients who underwent real-time ultrasound-guided cannulation of the internal jugular vein were prospectively compared with 450 critical care patients in whom the landmark technique was used. Randomisation was performed by means of a computer-generated random-numbers table, and patients were stratified with regard to age, gender, and body mass index. Results There were no significant differences in gender, age, body mass index, or side of cannulation (left or right) or in the presence of risk factors for difficult venous cannulation such as prior catheterisation, limited sites for access attempts, previous difficulties during catheterisation, previous mechanical complication, known vascular abnormality, untreated coagulopathy, skeletal deformity, and cannulation during cardiac arrest between the two groups of patients. Furthermore, the physicians who performed the procedures had comparable experience in the placement of central venous catheters (p = non-significant). Cannulation of the internal jugular vein was achieved in all patients by using ultrasound and in 425 of the patients (94.4%) by using the landmark technique (p < 0.001). Average access time (skin to vein) and number of attempts were significantly reduced in the ultrasound group of patients compared with the landmark group (p < 0.001). In the landmark group, puncture of the carotid artery occurred in 10.6% of patients, haematoma in 8.4%, haemothorax in 1.7%, pneumothorax in 2.4%, and central venous catheter-associated blood stream infection in 16%, which were all significantly increased compared with the ultrasound group (p < 0.001). Conclusion The present data suggest that ultrasound-guided catheterisation of the internal jugular vein in critical care patients is superior to the landmark technique and therefore should be the method of choice in these patients. PMID:17112371

  11. Mechanically assisted 3D ultrasound for pre-operative assessment and guiding percutaneous treatment of focal liver tumors

    NASA Astrophysics Data System (ADS)

    Sadeghi Neshat, Hamid; Bax, Jeffery; Barker, Kevin; Gardi, Lori; Chedalavada, Jason; Kakani, Nirmal; Fenster, Aaron

    2014-03-01

    Image-guided percutaneous ablation is the standard treatment for focal liver tumors deemed inoperable and is commonly used to maintain eligibility for patients on transplant waitlists. Radiofrequency (RFA), microwave (MWA) and cryoablation technologies are all delivered via one or a number of needle-shaped probes inserted directly into the tumor. Planning is mostly based on contrast CT/MRI. While intra-procedural CT is commonly used to confirm the intended probe placement, 2D ultrasound (US) remains the main, and in some centers the only imaging modality used for needle guidance. Corresponding intraoperative 2D US with planning and other intra-procedural imaging modalities is essential for accurate needle placement. However, identification of matching features of interest among these images is often challenging given the limited field-of-view (FOV) and low quality of 2D US images. We have developed a passive tracking arm with a motorized scan-head and software tools to improve guiding capabilities of conventional US by large FOV 3D US scans that provides more anatomical landmarks that can facilitate registration of US with both planning and intra-procedural images. The tracker arm is used to scan the whole liver with a high geometrical accuracy that facilitates multi-modality landmark based image registration. Software tools are provided to assist with the segmentation of the ablation probes and tumors, find the 2D view that best shows the probe(s) from a 3D US image, and to identify the corresponding image from planning CT scans. In this paper, evaluation results from laboratory testing and a phase 1 clinical trial for planning and guiding RFA and MWA procedures using the developed system will be presented. Early clinical results show a comparable performance to intra-procedural CT that suggests 3D US as a cost-effective alternative with no side-effects in centers where CT is not available.

  12. Treatment efficacy and safety of ultrasound-guided percutaneous bipolar radiofrequency ablation for benign thyroid nodules

    PubMed Central

    Li, Xiao-long; Lu, Feng; Yue, Wen-wen; Sun, Li-ping; Bo, Xiao-wan; Guo, Le-hang; Xu, Jun-mei; Liu, Bo-ji; Li, Dan-dan; Qu, Shen

    2016-01-01

    Objective: To evaluate the therapeutic efficacy and safety of ultrasound-guided percutaneous bipolar radiofrequency ablation (BRFA) of benign thyroid nodules by comparison with a matched untreated control group. Methods: The therapeutic efficacy and safety in 35 patients who were subjected to a single session of ultrasound-guided percutaneous BRFA (Group A) for benign thyroid nodules were compared with those in 35 untreated patients (Group B) with benign nodules. The benign nature of all the nodules was confirmed by ultrasound-guided fine-needle aspiration biopsy (FNAB), and all the patients had normal thyroid functions. BRFA was performed with a bipolar electrode (CelonProSurge 150–T20) with an output power of 20 W. Nodule volume, thyroid function and clinical symptoms of all the patients were compared before treatment and during follow-up. Results: In Group A, the BRFA procedures were completed with a mean time of 10.02 ± 3.30 min (range, 5.47–16.03 min) and with a mean total energy deposition of 10.747 ± 3704 J (range, 5510–17.770 J). The procedures were tolerated well in all the patients without causing any major complications. At the 6-month follow-up, all of the nodule volume decreased significantly (from 8.81 ± 8.66 to 1.59 ± 1.55 ml, p < 0.001) in Group A, whereas the nodule volume increased from 6.90 ± 3.77 to 7.87 ± 3.95 ml in Group B (p < 0.001). All (100%) the 35 nodules in Group A had volume reduction ratios (VRRs) of >50%, among which 3 (8.57%) had VRRs >90%. In Group A, the clinical symptoms of the patients who had symptoms before BRFA disappeared, whereas in Group B, the patients had no resolution of clinical symptoms at the 6-month follow-up. Conclusion: Ultrasound-guided percutaneous BRFA seems to be an effective and safe method for the treatment of benign thyroid nodules. It may gain a wide use in clinical practice. Advances in knowledge: Based on the comparable efficacy and clinical symptoms between the BRFA and untreated groups, the technique of BRFA can be used as an effective and safe method for the treatment of benign thyroid nodules. PMID:26800232

  13. Percutaneous nephrolithotomy in ectopically located kidneys and in patients with musculoskeletal deformities.

    PubMed

    Srivastava, A; Gupta, P; Chaturvedi, S; Singh, P; Kapoor, R; Dubey, D; Kumar, A

    2010-01-01

    To assess the feasibility, safety and results of percutaneous nephrolithotomy (PNL) in ectopically located kidneys and in patients with musculoskeletal deformities. Thirteen such patients underwent PNL between June 2005 and May 2008. Mean stone size was 27.4 mm (16-37 mm). Six patients had severe kyphoscoliosis, 2 patients each had achondroplasia, cross-fused ectopia and pelvic ectopic kidney, and 1 patient had thoracic kidney. All had a preoperative CT scan of the abdomen. Preoperative ultrasound- or CT-guided percutaneous nephrostomy (PCN) was done in 10 patients. Three patients underwent laparoscopic-assisted PNL. All underwent standard PNL. The stone-free rate, complication rate and need for secondary intervention were evaluated. PNL was successfully completed in all. A second ultrasound-guided intraoperative puncture was required in 2 patients. Re-look PNL was required in 1 patient and the same patient later required shock wave lithotripsy for complete stone clearance. The remaining 12 patients (92.3%) were rendered stone-free in a single sitting. PNL is a feasible and effective modality in anomalous kidneys. Preoperative planning with CT and image-guided PCN is helpful in these situations. Laparoscopic-assisted PNL can be safely performed in patients where access to a renal collecting system by fluoroscopy or image-guided assistance (ultrasound or CT scan) is not possible. Copyright (c) 2010 S. Karger AG, Basel.

  14. US-Guided Femoral and Sciatic Nerve Blocks for Analgesia During Endovenous Laser Ablation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yilmaz, Saim, E-mail: ysaim@akdeniz.edu.tr; Ceken, Kagan; Alimoglu, Emel

    2013-02-15

    Endovenous laser ablation may be associated with significant pain when performed under standard local tumescent anesthesia. The purpose of this study was to investigate the efficacy of femoral and sciatic nerve blocks for analgesia during endovenous ablation in patients with lower extremity venous insufficiency. During a 28-month period, ultrasound-guided femoral or sciatic nerve blocks were performed to provide analgesia during endovenous laser ablation in 506 legs and 307 patients. The femoral block (n = 402) was performed at the level of the inguinal ligament, and the sciatic block at the posterior midthigh (n = 124), by injecting a diluted lidocainemore » solution under ultrasound guidance. After the blocks, endovenous laser ablations and other treatments (phlebectomy or foam sclerotherapy) were performed in the standard fashion. After the procedures, a visual analogue pain scale (1-10) was used for pain assessment. After the blocks, pain scores were 0 or 1 (no pain) in 240 legs, 2 or 3 (uncomfortable) in 225 legs, and 4 or 5 (annoying) in 41 legs. Patients never experienced any pain higher than score 5. The statistical analysis revealed no significant difference between the pain scores of the right leg versus the left leg (p = 0.321) and between the pain scores after the femoral versus sciatic block (p = 0.7). Ultrasound-guided femoral and sciatic nerve blocks may provide considerable reduction of pain during endovenous laser and other treatments, such as ambulatory phlebectomy and foam sclerotherapy. They may make these procedures more comfortable for the patient and easier for the operator.« less

  15. Image-guided elbow interventions: a literature review of interventional treatment options

    PubMed Central

    Sorani, Alan

    2016-01-01

    Over the years, a wide range of image-guided interventional therapies have been used in treating different elbow pathologies, many of which are predominantly based on anecdotal and low-level study findings. This article critically assesses the existing literature and discusses the efficacy of the most commonly utilized interventional procedures for elbow pathology. PMID:26206415

  16. Quality of life assessment in interventional radiology.

    PubMed

    Monsky, Wayne L; Khorsand, Derek; Nolan, Timothy; Douglas, David; Khanna, Pavan

    2014-03-01

    The aim of this review was to describe quality of life (QoL) questionnaires relevant to interventional radiology. Interventional radiologists perform a large number of palliative procedures. The effect of these therapies on QoL is important. This is particularly true for cancer therapies where procedures with marginal survival benefits may result in tremendous QoL benefits. Image-guided minimally invasive procedures should be compared to invasive procedures, with respect to QoL, as part of comparative effectiveness assessment. A large number of questionnaires have been validated for measurement of overall and disease-specific quality of life. Use of applicable QoL assessments can aid in evaluating clinical outcomes and help to further substantiate the need for minimally invasive image-guided procedures. Copyright © 2014 AUR. Published by Elsevier Inc. All rights reserved.

  17. Models to teach lung sonopathology and ultrasound-guided thoracentesis.

    PubMed

    Wojtczak, Jacek A

    2014-12-01

    Lung sonography allows rapid diagnosis of lung emergencies such as pulmonary edema, hemothorax or pneumothorax. The ability to timely diagnose an intraoperative pneumothorax is an important skill for the anesthesiologist. However, lung ultrasound exams require an interpretation of not only real images but also complex acoustic artifacts such as A-lines and B-lines. Therefore, appropriate training to gain proficiency is important. Simulated environment using ultrasound phantom models allows controlled, supervised learning. We have developed hybrid models that combine dry or wet polyurethane foams, porcine rib cages and human hand simulating a rib cage. These models simulate fairly accurately pulmonary sonopathology and allow supervised teaching of lung sonography with the immediate feedback. In-vitro models can also facilitate learning of procedural skills, improving transducer and needle positioning and movement, rapid recognition of thoracic anatomy and hand - eye coordination skills. We described a new model to teach an ultrasound guided thoracentesis. This model consists of the experimenter's hand placed on top of the water-filled container with a wet foam. Metacarpal bones of the human hand simulate a rib cage and a wet foam simulates a diseased lung immersed in the pleural fluid. Positive fluid flow offers users feedback when a simulated pleural effusion is accurately assessed.

  18. Video networking of cardiac catheterization laboratories.

    PubMed

    Tobis, J; Aharonian, V; Mansukhani, P; Kasaoka, S; Jhandyala, R; Son, R; Browning, R; Youngblood, L; Thompson, M

    1999-02-01

    The purpose of this study was to assess the feasibility and accuracy of a video telecommunication network to transmit coronary images to provide on-line interaction between personnel in a cardiac catheterization laboratory and a remote core laboratory. A telecommunication system was installed in the cardiac catheterization laboratory at Kaiser Hospital, Los Angeles, and the core laboratory at the University of California, Irvine, approximately 40 miles away. Cineangiograms, live fluoroscopy, intravascular ultrasound studies and images of the catheterization laboratory were transmitted in real time over a dedicated T1 line at 768 kilobytes/second at 15 frames/second. These cases were performed during a clinical study of angiographic guidance versus intravascular ultrasound (IVUS) guidance of stent deployment. During the cases the core laboratory performed quantitative analysis of the angiograms and ultrasound images. Selected images were then annotated and transmitted back to the catheterization laboratory to facilitate discussion during the procedure. A successful communication hookup was obtained in 39 (98%) of 40 cases. Measurements of angiographic parameters were very close between the original cinefilm and the transmitted images. Quantitative analysis of the ultrasound images showed no significant difference in any of the diameter or cross-sectional area measurements between the original ultrasound tape and the transmitted images. The telecommunication link during the interventional procedures had a significant impact in 23 (58%) of 40 cases affecting the area to be treated, the size of the inflation balloon, recognition of stent underdeployment, or the existence of disease in other areas that was not noted on the original studies. Current video telecommunication systems provide high-quality images on-line with accurate representation of cineangiograms and intravascular ultrasound images. This system had a significant impact on 58% of the cases in this small clinical trial. Telecommunication networks between hospitals and a central core laboratory may facilitate physician training and improve technical skills and judgement during interventional procedures. This project has implications for how multicenter clinical trials could be operated through telecommunication networks to ensure conformity with the protocol.

  19. Multi-resolution Gabor wavelet feature extraction for needle detection in 3D ultrasound

    NASA Astrophysics Data System (ADS)

    Pourtaherian, Arash; Zinger, Svitlana; Mihajlovic, Nenad; de With, Peter H. N.; Huang, Jinfeng; Ng, Gary C.; Korsten, Hendrikus H. M.

    2015-12-01

    Ultrasound imaging is employed for needle guidance in various minimally invasive procedures such as biopsy guidance, regional anesthesia and brachytherapy. Unfortunately, a needle guidance using 2D ultrasound is very challenging, due to a poor needle visibility and a limited field of view. Nowadays, 3D ultrasound systems are available and more widely used. Consequently, with an appropriate 3D image-based needle detection technique, needle guidance and interventions may significantly be improved and simplified. In this paper, we present a multi-resolution Gabor transformation for an automated and reliable extraction of the needle-like structures in a 3D ultrasound volume. We study and identify the best combination of the Gabor wavelet frequencies. High precision in detecting the needle voxels leads to a robust and accurate localization of the needle for the intervention support. Evaluation in several ex-vivo cases shows that the multi-resolution analysis significantly improves the precision of the needle voxel detection from 0.23 to 0.32 at a high recall rate of 0.75 (gain 40%), where a better robustness and confidence were confirmed in the practical experiments.

  20. Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid

    MedlinePlus

    ... News Physician Resources Professions Site Index A-Z Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid ... Needle Aspiration Biopsy of the Thyroid? What is Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid? ...

  1. A prospective comparison of procedural sedation and ultrasound-guided interscalene nerve block for shoulder reduction in the emergency department.

    PubMed

    Blaivas, Michael; Adhikari, Srikar; Lander, Lina

    2011-09-01

    Emergency physicians (EPs) are beginning to use ultrasound (US) guidance to perform regional nerve blocks. The primary objective of this study was to compare length of stay (LOS) in patients randomized to US-guided interscalene block or procedural sedation to facilitate reduction of shoulder dislocation in the emergency department (ED). The secondary objectives were to compare one-on-one health care provider time, pain experienced by the patient during reduction, and patient satisfaction between the two groups. This was a prospective, randomized study of patients presenting to the ED with shoulder dislocation. The study was conducted at an academic Level I trauma center ED with an annual census of approximately 80,000. Patients were eligible for the study if they were at least 18 years of age and required reduction of a shoulder dislocation. A convenience sample of patients was randomized to either traditional procedural sedation or US-guided interscalene nerve block. Procedural sedation was performed with etomidate as the sole agent. Interscalene blocks were performed by hospital-credentialed EPs using sterile technique and a SonoSite MicroMaxx US machine with a high-frequency linear array transducer. Categorical variables were evaluated using Fisher's exact test, and continuous variables were analyzed using the Wilcoxon rank sum test. Forty-two patients were enrolled, with 21 patients randomized to each group. The groups were not significantly different with respect to sex or age. The mean (±SD) LOS in the ED was significantly higher in the procedural sedation group (177.3 ± 37.9 min) than in the US-guided interscalene block group (100.3 ± 28.2 minutes; p < 0.0001). The mean (±SD) one-on-one health care provider time was 47.1 (±9.8) minutes for the sedation group and 5 (±0.7) minutes for the US-guided interscalene block group (p < 0.0001). There was no statistically significant difference between the two groups in patient satisfaction or pain experienced during the procedure. There were no significant differences between groups with respect to complications such as hypoxia or hypotension (p = 0.49). In this study, patients undergoing shoulder dislocation reduction using US-guided interscalene block spent less time in the ED and required less one-on-one health care provider time compared to those receiving procedural sedation. There was no difference in pain level or satisfaction when compared to procedural sedation patients. © 2011 by the Society for Academic Emergency Medicine.

  2. Technical Note: Multipurpose CT, ultrasound, and MRI breast phantom for use in radiotherapy and minimally invasive interventions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ruschin, Mark, E-mail: Mark.Ruschin@sunnybrook.ca; Chin, Lee; Ravi, Ananth

    Purpose: To develop a multipurpose gel-based breast phantom consisting of a simulated tumor with realistic imaging properties in CT, ultrasound and MRI, or a postsurgical cavity on CT. Applications for the phantom include: deformable image registration (DIR) quality assurance (QA), autosegmentation validation, and localization testing and training for minimally invasive image-guided procedures such as those involving catheter or needle insertion. Methods: A thermoplastic mask of a typical breast patient lying supine was generated and then filled to make an array of phantoms. The background simulated breast tissue consisted of 32.4 g each of ballistic gelatin (BG) powder and Metamusil™ (MM)more » dissolved in 800 ml of water. Simulated tumors were added using the following recipe: 12 g of barium sulfate (1.4% v/v) plus 0.000 14 g copper sulfate plus 0.7 g of MM plus 7.2 g of BG all dissolved in 75 ml of water. The phantom was evaluated quantitatively in CT by comparing Hounsfield units (HUs) with actual breast tissue. For ultrasound and MRI, the phantoms were assessed based on subjective image quality and signal-difference to noise (SDNR) ratio, respectively. The stiffness of the phantom was evaluated based on ultrasound elastography measurements to yield an average Young’s modulus. In addition, subjective tactile assessment of phantom was performed under needle insertion. Results: The simulated breast tissue had a mean background value of 24 HU on CT imaging, which more closely resembles fibroglandular tissue (40 HU) as opposed to adipose (−100 HU). The tumor had a mean CT number of 45 HU, which yielded a qualitatively realistic image contrast relative to the background either as an intact tumor or postsurgical cavity. The tumor appeared qualitatively realistic on ultrasound images, exhibiting hypoechoic characteristics compared to background. On MRI, the tumor exhibited a SDNR of 3.7. The average Young’s modulus was computed to be 15.8 ± 0.7 kPa (1 SD). Conclusions: We have developed a process to efficiently and inexpensively produce multipurpose breast phantoms containing simulated tumors visible on CT, ultrasound, and MRI. The phantoms have been evaluated for image quality and elasticity and can serve as a medium for DIR QA, autosegmentation QA, and training for minimally invasive procedures.« less

  3. Out of hospital point of care ultrasound: current use models and future directions.

    PubMed

    Nelson, B P; Sanghvi, A

    2016-04-01

    Ultrasound has evolved from a modality that was once exclusively reserved to certain specialities of its current state, in which its portability and durability lend to its broadly increasing applications. This review describes portable ultrasound in the hospital setting and its comparison to gold standard imaging modalities. Also, this review summarizes current literature describing portable ultrasound use in prehospital, austere and remote environments, highlighting successes and barriers to use in these environments. Prehospital ultrasound has the ability to increase diagnostic ability and allow for therapeutic intervention in the field. In austere environments, ultrasound may be the only available imaging modality and thus can guide diagnosis, therapeutics and determine which patients may need emergent transfer to a healthcare facility. The most cutting edge applications of portable ultrasound employ telemedicine to obtain and transmit ultrasound images. This technology and ability to transmit images via satellite and cellular transmission can allow for even novice users to obtain interpretable images in austere environments. Portable ultrasound uses have steadily grown and will continue to do so with the introduction of more portable and durable technologies. As applications continue to grow, certain technologic considerations and future directions are explored.

  4. Ultrasound - Breast

    MedlinePlus

    ... the patient. Because ultrasound images are captured in real-time, they can show the structure and movement of ... perform an ultrasound-guided biopsy . Because ultrasound provides real-time images, it is often used to guide biopsy ...

  5. Needle segmentation using 3D Hough transform in 3D TRUS guided prostate transperineal therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Qiu Wu; Imaging Research Laboratories, Robarts Research Institute, Western University, London, Ontario N6A 5K8; Yuchi Ming

    Purpose: Prostate adenocarcinoma is the most common noncutaneous malignancy in American men with over 200 000 new cases diagnosed each year. Prostate interventional therapy, such as cryotherapy and brachytherapy, is an effective treatment for prostate cancer. Its success relies on the correct needle implant position. This paper proposes a robust and efficient needle segmentation method, which acts as an aid to localize the needle in three-dimensional (3D) transrectal ultrasound (TRUS) guided prostate therapy. Methods: The procedure of locating the needle in a 3D TRUS image is a three-step process. First, the original 3D ultrasound image containing a needle is cropped;more » the cropped image is then converted to a binary format based on its histogram. Second, a 3D Hough transform based needle segmentation method is applied to the 3D binary image in order to locate the needle axis. The position of the needle endpoint is finally determined by an optimal threshold based analysis of the intensity probability distribution. The overall efficiency is improved through implementing a coarse-fine searching strategy. The proposed method was validated in tissue-mimicking agar phantoms, chicken breast phantoms, and 3D TRUS patient images from prostate brachytherapy and cryotherapy procedures by comparison to the manual segmentation. The robustness of the proposed approach was tested by means of varying parameters such as needle insertion angle, needle insertion length, binarization threshold level, and cropping size. Results: The validation results indicate that the proposed Hough transform based method is accurate and robust, with an achieved endpoint localization accuracy of 0.5 mm for agar phantom images, 0.7 mm for chicken breast phantom images, and 1 mm for in vivo patient cryotherapy and brachytherapy images. The mean execution time of needle segmentation algorithm was 2 s for a 3D TRUS image with size of 264 Multiplication-Sign 376 Multiplication-Sign 630 voxels. Conclusions: The proposed needle segmentation algorithm is accurate, robust, and suitable for 3D TRUS guided prostate transperineal therapy.« less

  6. Efficacy of ropivacaine by the concentration of 0.25%, 0.5%, and 0.75% on surgical performance, postoperative analgesia, and patient’s satisfaction in inguinal hernioplasty: a randomized controlled trial

    PubMed Central

    Su, Yinglan; Zhang, Zhongjun; Zhang, Yaoxian; Li, Hanwei; Shi, Wei

    2015-01-01

    Background The purpose of this study was to evaluate the use of different concentrations of ropivacaine in ultrasound-guided regional anesthesia with regard to postoperative analgesic and patient’s satisfaction in elderly patients undergoing inguinal hernioplasty in the People’s Republic of China. Methods A total of 60 patients (>75 years of age) who scheduled inguinal hernioplasty at the Shenzhen People’s Hospital from December 2013 to March 2015 were randomly assigned to three groups: 0.25% ropivacaine (n=20), 0.5% ropivacaine (n=20), and 0.75% ropivacaine (n=20). Ultrasound-guided regional anesthesia was performed before every surgery. Non-invasive blood pressure and heart rate were recorded before the operation, during the first 5 minutes of the surgical procedure, and 5 minutes after the operation of the patients, and compared between the groups. Incidence of adverse reactions, postoperative Visual Analog Scale score, and analgesic effect were also recorded and analyzed. Results The surgical procedure and anesthesia was performed successfully in all patients. Patients with high-dose ropivacaine (0.5% and 0.75%) in ultrasound-guided regional anesthesia exhibited lower arterial pressure and lower heart rate during the operation when compared to low-dose group. The interquartile range of Visual Analog Scale scores in both group C (0.75% ropivacaine) and group B (0.5% ropivacaine) were significantly lower (P<0.05) than in group A (0.25% ropivacaine). Accordingly, the interquartile range of satisfactory scores in both group C (0.75% ropivacaine) and group B (0.5% ropivacaine) were significantly higher (P<0.05) than in group A (0.25% ropivacaine). More cases in high-dose groups reported abnormal skin sensation; however, it did not negatively affect the satisfaction level of patients. Conclusion The use of ultrasound-guided regional anesthesia with ropivacaine as an anesthetic in inguinal hernia repair for elderly patients is safe and effective, and ropivacaine is optimally effective at the concentration of 0.5% with least side effects. PMID:26445531

  7. Development of a fresh cadaver model for instruction of ultrasound-guided breast biopsy during the surgery clerkship: pre-test and post-test results among third-year medical students.

    PubMed

    McCrary, Hilary C; Krate, Jonida; Savilo, Christine E; Tran, Melissa H; Ho, Hang T; Adamas-Rappaport, William J; Viscusi, Rebecca K

    2016-11-01

    The aim of our study was to determine if a fresh cadaver model is a viable method for teaching ultrasound (US)-guided breast biopsy of palpable breast lesions. Third-year medical students were assessed both preinstruction and postinstruction on their ability to perform US-guided needle aspiration or biopsy of artificially created masses using a 10-item checklist. Forty-one third-year medical students completed the cadaver laboratory as part of the surgery clerkship. Eight items on the checklist were found to be significantly different between pre-testing and post-testing. The mean preinstruction score was 2.4, whereas the mean postinstruction score was 7.10 (P < .001). Fresh cadaver models have been widely used in medical education. However, there are few fresh cadaver models that provide instruction on procedures done in the outpatient setting. Our model was found to be an effective method for the instruction of US-guided breast biopsy among medical students. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Developing an automated database for monitoring ultrasound- and computed tomography-guided procedure complications and diagnostic yield.

    PubMed

    Itri, Jason N; Jones, Lisa P; Kim, Woojin; Boonn, William W; Kolansky, Ana S; Hilton, Susan; Zafar, Hanna M

    2014-04-01

    Monitoring complications and diagnostic yield for image-guided procedures is an important component of maintaining high quality patient care promoted by professional societies in radiology and accreditation organizations such as the American College of Radiology (ACR) and Joint Commission. These outcome metrics can be used as part of a comprehensive quality assurance/quality improvement program to reduce variation in clinical practice, provide opportunities to engage in practice quality improvement, and contribute to developing national benchmarks and standards. The purpose of this article is to describe the development and successful implementation of an automated web-based software application to monitor procedural outcomes for US- and CT-guided procedures in an academic radiology department. The open source tools PHP: Hypertext Preprocessor (PHP) and MySQL were used to extract relevant procedural information from the Radiology Information System (RIS), auto-populate the procedure log database, and develop a user interface that generates real-time reports of complication rates and diagnostic yield by site and by operator. Utilizing structured radiology report templates resulted in significantly improved accuracy of information auto-populated from radiology reports, as well as greater compliance with manual data entry. An automated web-based procedure log database is an effective tool to reliably track complication rates and diagnostic yield for US- and CT-guided procedures performed in a radiology department.

  9. Technical Advances in Endoscopic Ultrasound (EUS)-Guided Tissue Acquisition for Pancreatic Cancers: How Can We Get the Best Results with EUS-Guided Fine Needle Aspiration?

    PubMed Central

    Kedia, Prashant; Gaidhane, Monica

    2013-01-01

    Endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) is one of the least invasive and most effective modality in diagnosing pancreatic adenocarcinoma in solid pancreatic lesions, with a higher diagnostic accuracy than cystic tumors. EUS-FNA has been shown to detect tumors less than 3 mm, due to high spatial resolution allowing the detection of very small lesions and vascular invasion, particularly in the pancreatic head and neck, which may not be detected on transverse computed tomography. Furthermore, this minimally invasive procedure is often ideal in the endoscopic procurement of tissue in patients with unresectable tumors. While EUS-FNA has been increasingly used as a diagnostic tool, most studies have collectively looked at all primary pancreatic solid lesions, including lymphomas and pancreatic neuroendocrine neoplasms, whereas very few studies have examined the diagnostic utility of EUS-FNA of pancreatic ductal carcinoma only. As with any novel and advanced endoscopic procedure that may incorporate several practices and approaches, endoscopists have adopted diverse techniques to improve the tissue procurement practice and increase diagnostic accuracy. In this article, we present a review of literature to date and discuss currently practiced EUS-FNA technique, including indications, technical details, equipment, patient selection, and diagnostic accuracy. PMID:24143320

  10. Impact of Ultrasound on Short Peripheral Intravenous Catheter Placement on Vein Thrombosis Risk.

    PubMed

    Holder, Max R; Stutzman, Sonja E; Olson, DaiWai M

    Approximately 90% of hospitalized patients have a short peripheral intravenous catheter (SPC) placed. Methods of inserting the catheter have evolved over time and now include the use of ultrasound (US)-guided procedures for placement. Little is known about the impact that US-guided procedures have on the vein. This study compared the rate of venous thrombosis in patients with and without US-guided catheter placement. This prospective, single-blind, observational study assessed for venous thrombosis in 153 veins from 135 patients. Veins were evaluated by a research nurse blinded to the method of placement between 48 and 72 hours after the SPC was placed. The Fisher exact test showed a significant difference between vessel compressibility and catheter insertion method (P = .0012). The proportion of noncompressible veins was significantly greater when US was used in comparison with freehand SPC insertion. The Mantel-Haenszel chi-square value of 10.34 (P = .0013) showed that US insertion technique is associated with a higher likelihood of noncompressible veins. This pilot study provides compelling evidence that the use of US to assist with catheter placement is associated with a higher rate of noncompressible veins at day 2 or 3. Further studies are needed with a larger sample to determine the generalizability of the results from this pilot study.

  11. Endocavity Ultrasound Probe Manipulators

    PubMed Central

    Stoianovici, Dan; Kim, Chunwoo; Schäfer, Felix; Huang, Chien-Ming; Zuo, Yihe; Petrisor, Doru; Han, Misop

    2014-01-01

    We developed two similar structure manipulators for medical endocavity ultrasound probes with 3 and 4 degrees of freedom (DoF). These robots allow scanning with ultrasound for 3-D imaging and enable robot-assisted image-guided procedures. Both robots use remote center of motion kinematics, characteristic of medical robots. The 4-DoF robot provides unrestricted manipulation of the endocavity probe. With the 3-DoF robot the insertion motion of the probe must be adjusted manually, but the device is simpler and may also be used to manipulate external-body probes. The robots enabled a novel surgical approach of using intraoperative image-based navigation during robot-assisted laparoscopic prostatectomy (RALP), performed with concurrent use of two robotic systems (Tandem, T-RALP). Thus far, a clinical trial for evaluation of safety and feasibility has been performed successfully on 46 patients. This paper describes the architecture and design of the robots, the two prototypes, control features related to safety, preclinical experiments, and the T-RALP procedure. PMID:24795525

  12. Physical and cognitive task analysis in interventional radiology.

    PubMed

    Johnson, S; Healey, A; Evans, J; Murphy, M; Crawshaw, M; Gould, D

    2006-01-01

    To identify, describe and detail the cognitive thought processes, decision-making, and physical actions involved in the preparation and successful performance of core interventional radiology procedures. Five commonly performed core interventional radiology procedures were selected for cognitive task analysis. Several examples of each procedure being performed by consultant interventional radiologists were videoed. The videos of those procedures, and the steps required for successful outcome, were analysed by a psychologist and an interventional radiologist. Once a skeleton algorithm of the procedures was defined, further refinement was achieved using individual interview techniques with consultant interventional radiologists. Additionally a critique of each iteration of the established algorithm was sought from non-participating independent consultant interventional radiologists. Detailed task descriptions and decision protocols were developed for five interventional radiology procedures (arterial puncture, nephrostomy, venous access, biopsy-using both ultrasound and computed tomography, and percutaneous transhepatic cholangiogram). Identical tasks performed within these procedures were identified and standardized within the protocols. Complex procedures were broken down and their constituent processes identified. This might be suitable for use as a training protocol to provide a universally acceptable safe practice at the most fundamental level. It is envisaged that data collected in this way can be used as an educational resource for trainees and could provide the basis for a training curriculum in interventional radiology. It will direct trainees towards safe practice of the highest standard. It will also provide performance objectives of a simulator model.

  13. Implementation of real-time ultrasound in a thoracic surgery practice.

    PubMed

    Coonar, Aman S; Hughes, Jacqueline A; Walker, Susan; dePerrot, Marc; Waddell, Thomas K; Pierre, Andrew F; Darling, Gail E; Johnston, Michael R; Keshavjee, Shaf

    2009-05-01

    The purpose of this study was to implement real-time transthoracic ultrasound in a thoracic surgery and lung transplant practice. Ultrasound units that are light, small, robust, and portable are now available. Obstacles to use include demarcation issues between specialties, training, and a perception that basic ultrasound may be difficult to use. The experience of implementing this is described. After a training period, 62 studies were performed in 4 months. Patients and clinicians gave positive feedback. The learning time was short, and with ultrasonic guidance, all interventional procedures were successful at the first attempt, without any complications. Basic transthoracic ultrasound was found to be easy to learn and use by thoracic surgeons, fellows, and specialist nurses. Patients were appreciative. Real-time use may have genuine advantages to patient care.

  14. Percutaneous ultrasound-guided renal biopsy: A Libyan experience

    PubMed Central

    Mishra, A.; Tarsin, R.; ElHabbash, B.; Zagan, N.; Markus, R.; Drebeka, S.; AbdElmola, K.; Shawish, T.; Shebani, A.; AbdElmola, T.; ElUsta, A.; Ehtuish, E. F.

    2010-01-01

    This study was done to assess the safety and efficacy of ultrasound-guided percutaneous renal biopsy (PRB), to ascertain the risk factors for complications and determine the optimal period of observation. The radiologist (A.M.) at the National Organ Transplant Centre, Central Hospital, Tripoli, Libya, performed 86 PRBs between February 1, 2006, and January 31, 2008, using an automated biopsy gun with 16-gauge needle. Coagulation profile was done in all the patients. All patients were kept on strict bed rest for six hours post-procedure. Eighty six renal biopsies were performed on 78 patients referred from rheumatology department and eight post-kidney transplant recipients; 23 were males with age range 15 – 56 years and 63 females with age range 16 – 66 years. A mean of 17.5 glomeruli were present in each specimen. A glomerular yield of less than five glomeruli was seen in four biopsies. Class I lupus nephritis (LN) was seen in 1 patient, class II lupus nephritis in 7 patients, class III LN in 13 patients and class IV LN in 29 patients. All the eight renal allografts were diagnosed as acute tubular necrosis or acute interstitial rejection. The risk of post-biopsy bleeding was higher in women, older patients and higher PTT. The overall complication rate was 5.8%. Three complications were observed within six hours of biopsy. No late complication was seen. PRB under real-time ultrasound-guidance is a safe and efficacious procedure to establish the histological diagnosis and should be done as out-patient procedure. Observation time of six hours post-biopsy is optimal. PMID:20835320

  15. Gold nanoshelled liquid perfluorocarbon nanocapsules for combined dual modal ultrasound/CT imaging and photothermal therapy of cancer.

    PubMed

    Ke, Hengte; Yue, Xiuli; Wang, Jinrui; Xing, Sen; Zhang, Qian; Dai, Zhifei; Tian, Jie; Wang, Shumin; Jin, Yushen

    2014-03-26

    The integration of multimodal contrast-enhanced diagnostic imaging and therapeutic capabilities could utilize imaging guided therapy to plan the treatment strategy based on the diagnostic results and to guide/monitor the therapeutic procedures. Herein, gold nanoshelled perfluorooctylbromide (PFOB) nanocapsules with PEGylation (PGsP NCs) are constructed by oil-in-water emulsion method to form polymeric PFOB nanocapsules, followed by the formation of PEGylated gold nanoshell on the surface. PGsP NCs could not only provide excellent contrast enhancement for dual modal ultrasound and CT imaging in vitro and in vivo, but also serve as efficient photoabsorbers for photothermal ablation of tumors on xenografted nude mouse model. To our best knowledge, this is the first report of gold nanoshell serving as both CT contrast agents and photoabsorbers for photothermal therapy. The novel multifunctional nanomedicine would be of great value to offer more comprehensive diagnostic information to guide more accurate and effective cancer therapy. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. UBM-guided chamber angle surgery for glaucoma management: an experimental study.

    PubMed

    Dietlein, T S; Engels, B F; Jacobi, P C; Krieglstein, G K

    2003-04-01

    The aim of this experimental study was to investigate the potential of ultrasound bimicroscopy (UBM)-guided chamber angle surgery as an alternative or supplement to gonioscopy and intraocular microendoscopy for intraoperative control. In 15 porcine cadaver eyes, mechanical goniopuncture or punctual Er:YAG laser trabecular ablation was performed without operating microscope or gonioscopy, but with real-life ultrasound biomicroscopy monitoring with a 50 MHz transducer. Intraoperative localization of the microsurgical instruments and tissue-instrument contact were qualitatively evaluated. The instruments could be clearly visualized within the chamber angle and disturbing artefacts were only minimal when using mechanically fixed instruments in slow motion. Topographic localization, tissue contact, and penetration depth of the instruments entering the scleral were well illustrated as far as the technical resolution limits of UBM would allow. UBM can be used intraoperatively to monitor the correct manoeuvring of microsurgical instruments in selected ab interno procedures. Some adaptations and further modifications of the technique presented here will be necessary before UBM-guided surgery can be considered for clinical use in humans.

  17. Extended use of the GuideLiner in complex coronary interventions.

    PubMed

    Chan, Pak Hei; Alegria-Barrero, Eduardo; Foin, Nicholas; Paulo, Manuel; Lindsay, Alistair C; Viceconte, Nicola; Di Mario, Carlo

    2015-07-01

    Challenging coronary anatomies including chronic total occlusions (CTO), extreme vessel tortuosity, diseased bypass grafts, and anomalous coronary arteries pose difficulties in coronary interventions. The GuideLiner is a monorail catheter originally developed to facilitate delivery of stents to target lesions in tortuous vessels. We conducted a study on the feasibility and safety of utilising this catheter in a wider array of complex coronary interventions. Consecutive patients undergoing coronary or peripheral interventions where a GuideLiner was used were recruited into this study. Patient demographics, lesion and vessel characteristics, procedural details and outcomes were prospectively entered into our database and analysed. From September 2009 to October 2011, 54 consecutive patients underwent coronary intervention in our institution using a GuideLiner; 21 out of 54 coronary applications were motivated by the need to increase support to cross CTOs, predominantly of the RCA. Anomalous or angulated take-off of the treatment vessels (31%), previously deployed proximal stents (15%), heavy proximal calcification (9%) and tortuosity (7%) accounted for the remaining reasons. One patient had successful renal denervation with the aid of a GuideLiner catheter. Procedural success was 98% in our series with no device-related periprocedural complications such as ostial dissection or myocardial necrosis. The use of a GuideLiner facilitates the approach to complex coronary interventions including chronic total occlusion and saphenous vein graft intervention by providing greater back-up support and easier engagement of coronary ostia.

  18. Radiation exposure of the radiologist's eye lens during CT-guided interventions.

    PubMed

    Heusch, Philipp; Kröpil, Patric; Buchbender, Christian; Aissa, Joel; Lanzman, Rotem S; Heusner, Till A; Ewen, Klaus; Antoch, Gerald; Fürst, Günther

    2014-02-01

    In the past decade the number of computed tomography (CT)-guided procedures performed by interventional radiologists have increased, leading to a significantly higher radiation exposure of the interventionalist's eye lens. Because of growing concern that there is a stochastic effect for the development of lens opacification, eye lens dose reduction for operators and patients should be of maximal interest. To determine the interventionalist's equivalent eye lens dose during CT-guided interventions and to relate the results to the maximum of the recommended equivalent dose limit. During 89 CT-guided interventions (e.g. biopsies, drainage procedures, etc.) measurements of eye lens' radiation doses were obtained from a dedicated dosimeter system for scattered radiation. The sensor of the personal dosimeter system was clipped onto the side of the lead glasses which was located nearest to the CT gantry. After the procedure, radiation dose (µSv), dose rate (µSv/min) and the total exposure time (s) were recorded. For all 89 interventions, the median total exposure lens dose was 3.3 µSv (range, 0.03-218.9 µSv) for a median exposure time of 26.2 s (range, 1.1-94.0 s). The median dose rate was 13.9 µSv/min (range, 1.1-335.5 µSv/min). Estimating 50-200 CT-guided interventions per year performed by one interventionalist, the median dose of the eye lens of the interventional radiologist does not exceed the maximum of the ICRP-recommended equivalent eye lens dose limit of 20 mSv per year.

  19. Comparison of transcutaneous contrast-enhanced ultrasound-guided injected hemostatic agents with traditional surgery treatment for liver, spleen and kidney trauma: a retrospective study.

    PubMed

    Wang, Dong; Lv, Faqin; Luo, Yukun; An, Lichun; Li, Junlai; Xie, Xia; Tian, Jiangke; Zhao, Weiyan; Tang, Jie

    2012-10-01

    There is lack of studies on the effectiveness of transcutaneous contrast-enhanced ultrasound-guided injections of hemostatic agents for liver. spleen and kidney trauma. We compared treatment by hemostatic agents to surgical treatment in a retrospective interventional human study. The study enrolled a total of 135 subjects from emergency unit of the Chinese People's Liberation Army General Hospital in Beijing. Within the cohort, 62 patients received contrast enhanced ultrasound-guided injection of hemostatic agents and the rest received surgical treatments. The injury severity score was lower in the hemostatic agent treatment group than surgical treatment group (p<0.05), but Glasgow coma scale scores did not reach statistical significance. The patients in the surgical treatment group had significantly higher hospital fees than those in the hemostatic treatment group (p<0.05), although the length of hospitalization did not significantly differ between two groups. Safety outcome variables pre- and post-treatment remained within normal limits in both groups. Hemostatic agents were more cost-effective than surgery to treat patients with liver, spleen and kidney trauma. However, given the limited sample size, subsequent studies drawing upon larger populations from multiple medical centers are necessary for follow-up.

  20. 3-D ultrasound guidance of surgical robotics: a feasibility study.

    PubMed

    Pua, Eric C; Fronheiser, Matthew P; Noble, Joanna R; Light, Edward D; Wolf, Patrick D; von Allmen, Daniel; Smith, Stephen W

    2006-11-01

    Laparoscopic ultrasound has seen increased use as a surgical aide in general, gynecological, and urological procedures. The application of real-time, three-dimensional (RT3D) ultrasound to these laparoscopic procedures may increase information available to the surgeon and serve as an additional intraoperative guidance tool. The integration of RT3D with recent advances in robotic surgery also can increase automation and ease of use. In this study, a 1-cm diameter probe for RT3D has been used laparoscopically for in vivo imaging of a canine. The probe, which operates at 5 MHz, was used to image the spleen, liver, and gall bladder as well as to guide surgical instruments. Furthermore, the three-dimensional (3-D) measurement system of the volumetric scanner used with this probe was tested as a guidance mechanism for a robotic linear motion system in order to simulate the feasibility of RT3D/robotic surgery integration. Using images acquired with the 3-D laparoscopic ultrasound device, coordinates were acquired by the scanner and used to direct a robotically controlled needle toward desired in vitro targets as well as targets in a post-mortem canine. The rms error for these measurements was 1.34 mm using optical alignment and 0.76 mm using ultrasound alignment.

  1. Ultrasound-Guided Percutaneous Electrolysis and Eccentric Exercises for Subacromial Pain Syndrome: A Randomized Clinical Trial

    PubMed Central

    Arias-Buría, José L.; Truyols-Domínguez, Sebastián; Valero-Alcaide, Raquel; Salom-Moreno, Jaime; Atín-Arratibel, María A.; Fernández-de-las-Peñas, César

    2015-01-01

    Objective. To compare effects of ultrasound- (US-) guided percutaneous electrolysis combined with an eccentric exercise program of the rotator cuff muscles in subacromial pain syndrome. Methods. Thirty-six patients were randomized and assigned into US-guided percutaneous electrolysis (n = 17) group or exercise (n = 19) group. Patients were asked to perform an eccentric exercise program of the rotator cuff muscles twice every day for 4 weeks. Participants assigned to US-guided percutaneous electrolysis group also received the application of galvanic current through acupuncture needle on each session once a week (total 4 sessions). Shoulder pain (NPRS) and disability (DASH) were assessed at baseline, after 2 sessions, and 1 week after the last session. Results. The ANOVA revealed significant Group∗Time interactions for shoulder pain and disability (all, P < 0.01): individuals receiving US-guided percutaneous electrolysis combined with the eccentric exercises experienced greater improvement than those receiving eccentric exercise alone. Conclusions. US-guided percutaneous electrolysis combined with eccentric exercises resulted in small better outcomes at short term compared to when only eccentric exercises were applied in subacromial pain syndrome. The effect was statistically and clinically significant for shoulder pain but below minimal clinical difference for function. Future studies should investigate the long-term effects and potential placebo effect of this intervention. PMID:26649058

  2. Diagnostic Performance of Multiparametric Magnetic Resonance Imaging and Fusion Targeted Biopsy to Detect Significant Prostate Cancer.

    PubMed

    Hoffmann, Manuela A; Taymoorian, Kasra; Ruf, Christian; Gerhards, Arnd; Leyendecker, Karlheinz; Stein, Thomas; Jakobs, Frank M; Schreckenberger, Mathias

    2017-12-01

    Multiparametric magnetic resonance imaging combined with ultrasound-fusion-targeted biopsy of the prostate intends to increase diagnostic precision, which has to be clarified. We performed multiparametric magnetic resonance imaging followed by ultrasound-fusion-guided perineal biopsy in 99 male patients with elevated prostate-specific-antigen and previous negative standard biopsy-procedures. In 33/99 patients (33%) no malignancy could be confirmed by histopathology. Low-grade carcinomas (Gleason-Score 6+7a) were found in 42/66 (64%) and high-grade carcinomas (Gleason-Score ≥7b) in 24/66 (36%) men. A high-grade carcinoma corresponded to PI-RADS 4 or 5 (suspected malignancy) in 21/24 cases, which accounted for a sensitivity of 88% and negative-predictive-value of 85% (p=0.002). Differentiation between high-/low-grade carcinomas (Gleason-Score ≤7a vs. ≥7b) by means of PI-RADS related to a sensitivity of 88% and a negative-predictive-value of 70% (p=0.74). The results support the view that multiparametric magnetic resonance imaging/ultrasound-fusion-guided biopsy promotes considerably higher detection rates of clinically relevant prostate malignancies than do conventional diagnostic procedures. With regard to differentiation between high- and low-grade carcinomas, no significant difference was demonstrated. Copyright© 2017, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.

  3. Intravascular Ultrasound Guidance for Transjugular Intrahepatic Portosystemic Shunt Procedure in a Swine Model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kew, Jacqueline; Davies, Roger P.

    2004-01-15

    A new method is described for guiding hepato-portalvenous puncture using a longitudinal side-view intravascular ultrasound(L-IVUS) transducer to assist in the performance of transjugularintrahepatic portosystemic shunt (TIPS) in three Australian swine.Simultaneous L-IVUS with an AcuNav (registered) 5-10 MHz 10 Fr transducer(Acuson Corporation, Mountain View, CA, USA) and fluoroscopy guidance was used to image and monitor the hepatic to portal venous puncture,dilatation of the tract, and deployment of the TIPS stent. Flow through the shunt could be demonstrated with both L-IVUS and angiography. TIPS was successful in all swine. The time for portal vein puncture once the target portal vein was identifiedmore » was reduced at each attempt. The number of portal vein puncture attempts was 2, 1, and 1. No post-procedural complication was evident. L-IVUS-guided TIPS is practical and has the potential to improve safety by permitting simultaneous ultrasound and fluoroscopic imaging of the needle and target vascular structures. This technique allows for a more streamlined approach to TIPS, decreasing the fluoroscopic time (hence,decreasing the radiation exposure to the staff and patient) and anesthetic time. In addition, there are improved safety benefits obviating the need for wedged portography, facilitating avoidance of bile duct and hepatic arterial puncture, and minimizing hepatic injury by decreasing liver capsular puncture and the attendant risks.« less

  4. Ultrasound and bronchoscopic controlled percutaneous tracheostomy on trauma ICU.

    PubMed

    Kollig, E; Heydenreich, U; Roetman, B; Hopf, F; Muhr, G

    2000-11-01

    Tracheostomy is a common surgical procedure performed in long-term ventilated patients in intensive care. Since the role of percutaneous dilatational tracheostomy (PDT) on Intensive Care Unit (ICU) has become steadily more important in the last few years, a prospective study was started to evaluate the economic efficiency and to show the minimization of the complication rate of this procedure. In 72 patients we performed PDT as a bedside procedure. Initially the thyroid gland and the subcutaneous vessels were studied by ultrasound in every patient. The puncture of the trachea, the dilatational procedure and the insertion of the tracheal cannula were executed under bronchoscopic monitoring. Finally, a bronchoscopic control view followed via the new cannula to detect intratracheal complications. Mechanical ventilation was maintained during the procedure and controlled by continuous pulse oximetry. According to prior ultrasound findings the place to puncture the trachea was changed in 24% of the patients, in one case tracheostomy was performed as an open conventional procedure. The following complications could be observed: one case involving perforation of a cartilaginous ring, one case with venous bleeding of a small subcutaneous vein and two cases with punctures of the bronchoscope. There were no cases of miscannulation, penetration of the posterior tracheal wall or major bleeding requiring intervention or conversion. The followup study revealed that there was no sign of further complications in any patient. In addition, cost analysis demonstrated that there was a significant economical advantage of PDT in comparison with open standard tracheostomy. Standardized ultrasonographically and bronchoscopically controlled PDT turns out to be a safe, simple and cost effective bedside procedure on ICU. Because of ultrasound examination performed before the procedure, and bronchoscopic surveillance during the procedure, safety of this procedure can be enhanced, thus minimizing the rate of complications.

  5. Quality-of-Life Assessment of Fibroid Treatment Options and Outcomes

    PubMed Central

    Kong, Chung Yin; Tempany, Clare M.; Swan, J. Shannon

    2011-01-01

    Purpose: To obtain utilities (a unit of measure of a person’s relative preferences for different health states compared with death or worst possible outcome) for uterine fibroids before and after treatment and to measure short-term utilities for the following uterine fibroid treatments: abdominal hysterectomy, magnetic resonance (MR) imaging–guided focused ultrasound surgery, and uterine artery embolization (UAE). Materials and Methods: This retrospective study was approved by the institutional review board and was HIPAA compliant. The waiting trade-off (WTO) method, a variation on the time trade-off (TTO) method, is used to obtain utilities for diagnostic procedures on the basis of the fact that people wait longer to avoid noxious tests and/or procedures. The WTO method provides short-term quality of life tolls in terms of quality-adjusted life-weeks by scaling wait times with pre- and posttreatment utilities. Utilities for uterine fibroids before and after treatment were obtained with the TTO method and a visual analog scale (VAS) by using a questionnaire administered by means of a phone interview. WTO wait times were adjusted for quality of life with VAS and TTO utilities and a transformation of VAS. Wait times were compared by using nonparametric tests. The study participants included 62 patients who had undergone abdominal hysterectomy, 74 who had undergone UAE, and 61 who had undergone MR imaging–guided focused ultrasound surgery. Results: Quality of life increased with all treatments. The median WTO wait time was higher for hysterectomy (21.6 weeks) than for UAE or MR imaging–guided focused ultrasound surgery (14.1 weeks for both) (P < .05). Quality-adjusted life-week tolls were smaller when scaled according to TTO than when scaled according to VAS or transformation of VAS. Conclusion: Quality of life increased after all fibroid treatments. WTO is feasible for assessing the quality-adjusted morbidity of treatment procedures. © RSNA, 2011 Supplemental material: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.11100704/-/DC1 PMID:21364084

  6. Rehabilitation and Prevention of Proximal Hamstring Tendinopathy.

    PubMed

    Beatty, Nicholas R; Félix, Ioonna; Hettler, Jessica; Moley, Peter J; Wyss, James F

    Proximal hamstring tendinopathy (PHT) comprises a small but significant portion of hamstring injuries in athletes, especially runners. PHT is a chronic condition that is clinically diagnosed but can be supported with imaging. The main presenting complaint is pain in the lower gluteal or ischial region that may or may not radiate along the hamstrings in the posterior thigh. There is little scientific evidence on which to base the rehabilitation management of PHT. Treatment is almost always conservative, with a focus on activity modification, addressing contributing biomechanical deficiencies, effective tendon loading including eccentric training, and ultrasound-guided interventional procedures which may facilitate rehabilitation. Surgery is limited to recalcitrant cases or those involving concomitant high-grade musculotendinous pathology. The keys to PHT management include early and accurate diagnosis, optimal rehabilitation to allow for a safe return to preinjury activity level, and preventative strategies to reduce risk of reinjury.

  7. [MR-guided focused ultrasound. Current and future applications].

    PubMed

    Trumm, C G; Napoli, A; Peller, M; Clevert, D-A; Stahl, R; Reiser, M; Matzko, M

    2013-03-01

    High-intensity focused ultrasound (synonyms FUS and HIFU) under magnetic resonance imaging (MRI) guidance (synonyms MRgFUS and MR-HIFU) is a completely non-invasive technology for accurate thermal ablation of a target tissue while neighboring tissues and organs are preserved. The combination of FUS with MRI for planning, (near) real-time monitoring and outcome assessment of treatment markedly enhances the safety of the procedure. The MRgFUS procedure is clinically established in particular for the treatment of symptomatic uterine fibroids, followed by palliative ablation of painful bone metastases. Furthermore, promising results have been shown for the treatment of adenomyosis, malignant tumors of the prostate, breast and liver and for various intracranial applications, such as thermal ablation of brain tumors, functional neurosurgery and transient disruption of the blood-brain barrier.

  8. Randomized pilot study to compare metal needles versus plastic cannulae in the development of complications in hemodialysis access.

    PubMed

    Marticorena, Rosa M; Dacouris, Niki; Donnelly, Sandra M

    2018-05-01

    Hemodialysis requires needle insertions every treatment. Needle injury (mechanical or hemodynamic) may cause complications (aneurysms/stenosis) that compromise dialysis delivery requiring interventions. Metal needles have a sharp slanted "V"-shaped cutting tip; plastic cannulae have a dull round tip and four side holes. Preliminary observations demonstrated a difference in intradialytic blood flow images and mean Doppler velocities at cannulation sites between the two devices. Complications from mechanical and hemodynamic trauma requiring interventions were compared in each group. In all, 33 patients (13 females and 17 new accesses) were randomized to metal group (n = 17) and plastic group (n = 16). Mechanical trauma was minimized by having five nurses performing ultrasound-guided cannulations. Complications were identified by the clinician and addressed by the interventionalists, both blinded to study participation. Patients were followed for up to 12 months. Baseline characteristics were not significant. Procedures to treat complications along cannulation segments increased from 0.41 to 1.29 per patient (metal group) and decreased from 1.25 to 0.69 per patient (plastic group; p = 0.004). The relative risks of having an intervention (relative risk = 1.5, 95% confidence interval = 0.88-2.67) and having an infiltration during hemodialysis (relative risk = 2.26, 95% confidence interval = 1.03-4.97) were higher for metal needles. Time to first intervention trended in favor of plastic cannula (p = 0.069). Cost of supplies for these interventions was approximately CAD$20,000 lower for the plastic group. Decreased burden of illness related to cannulation (less infiltrations during hemodialysis) and Qb were associated with plastic cannulae. Decreased procedure costs were suggested during the study period in the plastic group.

  9. Randomized and controlled prospective trials of Ultrasound-guided spinal nerve posterior ramus pulsed radiofrequency treatment for lower back post-herpetic neuralgia.

    PubMed

    Pi, Z B; Lin, H; He, G D; Cai, Z; Xu, X Z

    2015-01-01

    To evaluate the efficacy of ultrasound-guided spinal nerve posterior ramus pulsed radiofrequency treatment for lower back post-herpetic neuralgia. 128 cases of lower back or anterior abdominal wall acute post-herpetic neuralgia patients were selected. They were randomly divided into two groups. Group A: oral treatment only with gabapentin + celecoxib + amitriptyline. Group B: while taking these drugs, patients were treated with radiofrequency (RF) pulses using a portable ultrasound device using the paravertebral puncture technique. In both groups, sudden outbreaks of pain were treated with immediate release 10mg morphine tablets. Visual analogue scale (VAS) was used for pain score, Pittsburgh Sleep Quality Index scale (PSQI) was used to evaluate sleep quality and morphine consumption were recorded at different time points, before and after treatment. Treatment efficiency was calculated while the occurrence of complications was documented. At each time point after treatment, VAS scores were lower, but scores in the RF group was significantly lower than those of the oral-only group. In terms of sleep quality scores and morphine consumption between the two groups, the RF group was significantly lower than the oral-only group. During the procedure no error occurred with needle penetrating the abdominal cavity, chest, offal or blood vessels. Ultrasound-guided spinal nerve posterior ramus pulsed radiofrequency treatment of lower back or anterior abdominal wall post-herpetic neuralgia proved effective by reducing morphine use in patients and led to fewer adverse reactions.

  10. Ultrasound-guided plantar fascia release technique: a retrospective study of 46 feet.

    PubMed

    Vohra, Praveen K; Japour, Christopher J

    2009-01-01

    Ultrasound-guided plantar fascia release offers the surgeon clear visualization of anatomy at the surgical site. This technique uses small arthroscopic dissecting instruments through a 0.5-cm incision, allowing the surgeon to avoid the larger and more tissue-disruptive incision that is traditionally used for plantar heel spur resection and plantar fascia releases. Forty-one patients (46 feet) were selected for the study. The mean patient age was 47 years. Twenty-nine were considered obese with a body mass index greater than 30 kg/m(2). Patients were functionally and subjectively evaluated 4 weeks after surgery using the American Orthopedic Foot and Ankle Society Ankle and Hindfoot Rating Scale. Results from the study show a significant improvement (P = .05 confidence level) 4 weeks postoperatively for the 41 patients (46 feet), compared to their preoperative condition. The mean pretest score was 33.6 (range 10-52); this score improved to 88.0 (range 50-100), 4 weeks postoperatively. There were no postoperative infections or complications. The ultrasound-guided plantar fascia release technique is a practical surgical procedure for the relief of chronic plantar fascia pain because the surgeon is able to clearly visualize the plantar fascia by ultrasound. In addition, there is minimal disruption to surrounding tissue because small instruments are passed through a small 0.5-cm incision. The traditional open method of heel spur surgery, in contrast, uses a larger skin incision of 3 to 5 cm, followed by larger instruments to dissect to the plantar fascia.

  11. Real-time registration of 3D to 2D ultrasound images for image-guided prostate biopsy.

    PubMed

    Gillies, Derek J; Gardi, Lori; De Silva, Tharindu; Zhao, Shuang-Ren; Fenster, Aaron

    2017-09-01

    During image-guided prostate biopsy, needles are targeted at tissues that are suspicious of cancer to obtain specimen for histological examination. Unfortunately, patient motion causes targeting errors when using an MR-transrectal ultrasound (TRUS) fusion approach to augment the conventional biopsy procedure. This study aims to develop an automatic motion correction algorithm approaching the frame rate of an ultrasound system to be used in fusion-based prostate biopsy systems. Two modes of operation have been investigated for the clinical implementation of the algorithm: motion compensation using a single user initiated correction performed prior to biopsy, and real-time continuous motion compensation performed automatically as a background process. Retrospective 2D and 3D TRUS patient images acquired prior to biopsy gun firing were registered using an intensity-based algorithm utilizing normalized cross-correlation and Powell's method for optimization. 2D and 3D images were downsampled and cropped to estimate the optimal amount of image information that would perform registrations quickly and accurately. The optimal search order during optimization was also analyzed to avoid local optima in the search space. Error in the algorithm was computed using target registration errors (TREs) from manually identified homologous fiducials in a clinical patient dataset. The algorithm was evaluated for real-time performance using the two different modes of clinical implementations by way of user initiated and continuous motion compensation methods on a tissue mimicking prostate phantom. After implementation in a TRUS-guided system with an image downsampling factor of 4, the proposed approach resulted in a mean ± std TRE and computation time of 1.6 ± 0.6 mm and 57 ± 20 ms respectively. The user initiated mode performed registrations with in-plane, out-of-plane, and roll motions computation times of 108 ± 38 ms, 60 ± 23 ms, and 89 ± 27 ms, respectively, and corresponding registration errors of 0.4 ± 0.3 mm, 0.2 ± 0.4 mm, and 0.8 ± 0.5°. The continuous method performed registration significantly faster (P < 0.05) than the user initiated method, with observed computation times of 35 ± 8 ms, 43 ± 16 ms, and 27 ± 5 ms for in-plane, out-of-plane, and roll motions, respectively, and corresponding registration errors of 0.2 ± 0.3 mm, 0.7 ± 0.4 mm, and 0.8 ± 1.0°. The presented method encourages real-time implementation of motion compensation algorithms in prostate biopsy with clinically acceptable registration errors. Continuous motion compensation demonstrated registration accuracy with submillimeter and subdegree error, while performing < 50 ms computation times. Image registration technique approaching the frame rate of an ultrasound system offers a key advantage to be smoothly integrated to the clinical workflow. In addition, this technique could be used further for a variety of image-guided interventional procedures to treat and diagnose patients by improving targeting accuracy. © 2017 American Association of Physicists in Medicine.

  12. Clinical Utility and Pitfalls of Ultrasound Guided Foreign Body Removal in War Fighters

    DTIC Science & Technology

    2015-12-01

    1 AD_________________ AWARD NUMBER: W81XWH-08-2-0162 TITLE: Clinical Utility and Pitfalls of Ultrasound Guided Foreign Body Removal in War...Clinical Utility and Pitfalls of Ultrasound Guided Foreign Body Removal in War Fighters 5a. CONTRACT NUMBER 5b. GRANT NUMBER: W81XWH-08-2-0162 5c...Purpose: To demonstrate that 1) ultrasound guided foreign body removal (USFBR) is superior to conventional surgery in the cadaver model, 2) USFBR can be

  13. Endobronchial ultrasound elastography: a new method in endobronchial ultrasound-guided transbronchial needle aspiration.

    PubMed

    Jiang, Jun-Hong; Turner, J Francis; Huang, Jian-An

    2015-12-01

    TBNA through the flexible bronchoscope is a 37-year-old technology that utilizes a TBNA needle to puncture the bronchial wall and obtain specimens of peribronchial and mediastinal lesions through the flexible bronchoscope for the diagnosis of benign and malignant diseases in the mediastinum and lung. Since 2002, the Olympus Company developed the first generation ultrasound equipment for use in the airway, initially utilizing an ultrasound probe introduced through the working channel followed by incoroporation of a fixed linear ultrasound array at the distal tip of the bronchoscope. This new bronchoscope equipped with a convex type ultrasound probe on the tip was subsequently introduced into clinical practice. The convex probe (CP)-EBUS allows real-time endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) of mediastinal and hilar lymph nodes. EBUS-TBNA is a minimally invasive procedure performed under local anesthesia that has been shown to have a high sensitivity and diagnostic yield for lymph node staging of lung cancer. In 10 years of EBUS development, the Olympus Company developed the second generation EBUS bronchoscope (BF-UC260FW) with the ultrasound image processor (EU-M1), and in 2013 introduced a new ultrasound image processor (EU-M2) into clinical practice. FUJI company has also developed a curvilinear array endobronchial ultrasound bronchoscope (EB-530 US) that makes it easier for the operator to master the operation of the ultrasonic bronchoscope. Also, the new thin convex probe endobronchial ultrasound bronchoscope (TCP-EBUS) is able to visualize one to three bifurcations distal to the current CP-EBUS. The emergence of EBUS-TBNA has also been accompanied by innovation in EBUS instruments. EBUS elastography is, then, a new technique for describing the compliance of structures during EBUS, which may be of use in the determination of metastasis to the mediastinal and hilar lymph nodes. This article describes these new EBUS techniques and reviews the relevant literature.

  14. One-step endosonography-guided drainage of a pancreatic pseudocyst: a new technique of stent delivery through the echo endoscope.

    PubMed

    Vilmann, P; Hancke, S; Pless, T; Schell-Hincke, J D; Henriksen, F W

    1998-10-01

    We report here the first case of a one-step endosonography(EUS)-guided pseudocyst drainage. A prototype large channel curved array echo endoscope (Pentax FG-38 UX) and a prototype delivery system for placement of an endoprosthesis was used for the procedure. The delivery system (GIP MedicinTechnik GmbH/Medi-Globe Corporation) consists of a handle part with a piston, a metal ring sheath, a plastic catheter with a diathermy needle and a double pigtail endoprosthesis (8.5 Fr). When mounted on the endoscope the endoprosthesis can be advanced out of the distal end of the endoscope. The introduction of the stent as well as the stent release can be monitored entirely by ultrasound. The procedure was tested in a 76-year-old woman with a pseudocyst measuring 60 mm in diameter located in the tail of the pancreas. The procedure was well tolerated by the patient, and there were no procedural complications. The advantage of a large channel echo endoscope and our new prototype delivery system is that the endoprosthesis can be inserted in to a pancreatic cyst guided exclusively by EUS without exchange of endoscopes, catheters or guide wires. Further studies are warranted.

  15. The NifTK software platform for image-guided interventions: platform overview and NiftyLink messaging.

    PubMed

    Clarkson, Matthew J; Zombori, Gergely; Thompson, Steve; Totz, Johannes; Song, Yi; Espak, Miklos; Johnsen, Stian; Hawkes, David; Ourselin, Sébastien

    2015-03-01

    To perform research in image-guided interventions, researchers need a wide variety of software components, and assembling these components into a flexible and reliable system can be a challenging task. In this paper, the NifTK software platform is presented. A key focus has been high-performance streaming of stereo laparoscopic video data, ultrasound data and tracking data simultaneously. A new messaging library called NiftyLink is introduced that uses the OpenIGTLink protocol and provides the user with easy-to-use asynchronous two-way messaging, high reliability and comprehensive error reporting. A small suite of applications called NiftyGuide has been developed, containing lightweight applications for grabbing data, currently from position trackers and ultrasound scanners. These applications use NiftyLink to stream data into NiftyIGI, which is a workstation-based application, built on top of MITK, for visualisation and user interaction. Design decisions, performance characteristics and initial applications are described in detail. NiftyLink was tested for latency when transmitting images, tracking data, and interleaved imaging and tracking data. NiftyLink can transmit tracking data at 1,024 frames per second (fps) with latency of 0.31 milliseconds, and 512 KB images with latency of 6.06 milliseconds at 32 fps. NiftyIGI was tested, receiving stereo high-definition laparoscopic video at 30 fps, tracking data from 4 rigid bodies at 20-30 fps and ultrasound data at 20 fps with rendering refresh rates between 2 and 20 Hz with no loss of user interaction. These packages form part of the NifTK platform and have proven to be successful in a variety of image-guided surgery projects. Code and documentation for the NifTK platform are available from http://www.niftk.org . NiftyLink is provided open-source under a BSD license and available from http://github.com/NifTK/NiftyLink . The code for this paper is tagged IJCARS-2014.

  16. Ultrasound-guided hydrostatic reduction of intussusception with saline: Safe and effective.

    PubMed

    Karadağ, Çetin Ali; Abbasoğlu, Latif; Sever, Nihat; Kalyoncu, Meltem Kaba; Yıldız, Abdullah; Akın, Melih; Candan, Mustafa; Dokucu, Ali İhsan

    2015-09-01

    The study was undertaken to assess the efficacy of ultrasound-guided saline enema in reducing intussusception and to determine the role of age and duration of symptoms on this event. The case records of patients who were treated for intussusception at our institutions over the past 10 years were retrospectively analyzed. A total of 419 patients were treated for intussusception and 375 of them were included into the study. Patients were excluded if they had symptoms and signs of acute abdominal disease and required surgery as an initial treatment. Hydrostatic reduction was successful in 313 of the 375 patients (83.46%). The procedure-related complication rate was nil. There were 29 episodes of recurrences in 23 patients, and recurrence rates did not differ between patients who responded to hydrostatic reduction and those who required surgery. Younger age [median (range); 11 months (3-108 months) vs. 20 months (1-180 months); p<0.05], rectal bleeding (p<0.01) and long duration of symptoms [mean (range); 1.95 days (1-7 days) vs. 1.44 days (1-10 days); p<0.01] were significantly associated with failed hydrostatic reduction. Ultrasound-guided hydrostatic reduction is an easy, safe and effective method for the treatment of intussusception in the absence of acute abdominal findings. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Technical communication: new teaching model for practicing ultrasound-guided regional anesthesia techniques: no perishable food products!

    PubMed

    Liu, Yang; Glass, Nancy L; Power, Robert W

    2010-04-01

    There is a pronounced learning curve for the technique of ultrasound-guided regional anesthesia. Practicing with a simulator model has been shown to speed the acquisition of these skills for various ultrasound-guided procedures. However, commercial models for ultrasound-guided regional anesthesia may be too costly or not readily available. Models using turkey breasts or tofu blocks have the disadvantage of containing perishable food products that can be a source for infection. We describe an alternative inexpensive model that is made from nonperishable components readily available in the operating room. The materials required include 1 clean used 500-mL bag of IV fluids, a bottle of Premisorb (TYCO Healthcare Group, Mansfield, MA), and a piece of foam material approximately 0.3 cm in diameter and 5 cm in length trimmed from operating room foam pads. After filling the IV bag with tap water and inserting the foam into the IV bag from the outlet port of the IV bag, one-third of a bottle of Premisorb (approximately 15 g) is poured into the IV bag. The outlet port of the bag is then sealed by taping the rubber stopper that originally came with the bag. Premisorb, a solidifying agent frequently used to absorb irrigating fluids or blood in operating room suction canisters, produces a gel-like material in the IV bag. The foam inserted into the bag creates a relatively hyperechoic target. This gel-like substance in the bag will seal the holes created after multiple practice needle insertions, resulting in minimal leakage. The semitransparent nature of the gel allows the trainee to visualize the target directly and on the ultrasound screen. The model we describe is inexpensive and easy to make from materials readily available in the operating room with the advantages of being nonperishable, easy to carry, and reusable.

  18. [Interscalene block for total shoulder arthroplasty: comparative study (ultrasound vs. neurostimulation)].

    PubMed

    Mejía-Terrazas, Gabriel Enrique; Ruiz-Suárez, Michell; Gaspar-Carrillo, Sandra Patricia; Valero-González, Fernando; Unzueta-Navarro, David; Encalada-Díaz, Iván

    2014-01-01

    Modern anesthesiology has integrated the use of ultrasonography as a tool that has displaced neurostimulation as a technique for locating peripheral nerves. The aim of this study was to determine which procedure is more effective for guiding interscalene block for total shoulder arthroplasty. We carried out a comparative, prospective non-randomized study comprised of the group guided by neurostimulation interscalene block and the group guided by ultrasound. All patients in both groups were scheduled for total shoulder arthroplasty. Latency, degree of sensory and motor block, success rate, postoperative pain intensity at 6, 12, and 24 h, patient satisfaction and complications were measured. We included 110 patients, 55 per group. Patients were placed in beach chair position and the deltopectoral approach was used. There were no differences in demographic characteristics. Results for neurostimulation vs. ultrasound group: latency 19.11 ± 2.27 vs. 17.24 ± 1.42 min, p= 0.23. Block sensitivity in both groups was grade 0 motor block grade 0 in 76.4% and grade 1 in 23.6% vs. grade 0 to 100%. There was 100% success rate for both groups. Postoperative pain at 6 h was 0.13 ± 0.54 vs. 0.11 ± 0.13 p= 0.90, at 12 h 1.67 ± 1.15 vs. 1.65 ± 0.59 p= 0.89 and at 24 h 3.15 ± 1.66 vs. 2.99 ± 1.15 p= 0.78. Satisfaction 54.5% very satisfied and 45.5% satisfied 96.36% vs 3.6% very satisfied and satisfied. Complications 18.18% vs. 3.6% p= 0.023. Ultrasound-guided interscalene nerve block is the technique of choice in elective total shoulder arthroplasty.

  19. Flurbiprofen Axetil Provides Effective Analgesia Without Changing the Pregnancy Rate in Ultrasound-Guided Transvaginal Oocyte Retrieval: A Double-Blind Randomized Controlled Trial.

    PubMed

    Zhao, Hong; Feng, Yi; Jiang, Yan; Lu, Qun

    2017-10-01

    In this prospective double-blind randomized study, we evaluated the analgesic effect and potential effect on pregnancy rate of the nonsteroidal anti-inflammatory drug flurbiprofen axetil in patients undergoing ultrasound-guided transvaginal oocyte retrieval under propofol-remifentanil anesthesia. A total of 200 patients scheduled to undergo ultrasound-guided transvaginal oocyte retrieval were randomly allocated to receive 1.5 mg/kg of flurbiprofen axetil (FA group) or placebo (control group) 30 minutes before the procedure. Postoperative pain scores, embryo implantation rate, and pregnancy rate were recorded. Neuroendocrine biomarkers and prostaglandin E2 levels in follicular fluid were tested after oocyte retrieval. Patients in the FA group awakened earlier after surgery than patients in the control group (3.3 ± 2.6 vs 5.3 ± 3.4 minutes, P < .05) and had lower pain scores than patients in the control group (2.0 [0.0, 2.8] vs 5.0 [3.0, 5.0], P< .001). The difference in pregnancy rates between the 2 groups (44%-44%) was 0% (conventional 2-sided 95% confidence interval, -13.8% to 13.8%). The lower limit of the 90% 1-sided confidence interval for this difference was -9.0%, which was within the predefined noninferiority margin of -15.0%. The concentration of prostaglandin E2 in follicular fluid was decreased in the FA group (24.51 ± 1.52 vs 25.15 ± 1.49 pg/mL, P = .039), although the difference does not appear to be clinically important. Flurbiprofen axetil given before ultrasound-guided transvaginal oocyte retrieval for patients under propofol-remifentanil general anesthesia relieves pain without any detrimental effect on clinical pregnancy rate.

  20. Real-time three-dimensional optical coherence tomography image-guided core-needle biopsy system.

    PubMed

    Kuo, Wei-Cheng; Kim, Jongsik; Shemonski, Nathan D; Chaney, Eric J; Spillman, Darold R; Boppart, Stephen A

    2012-06-01

    Advances in optical imaging modalities, such as optical coherence tomography (OCT), enable us to observe tissue microstructure at high resolution and in real time. Currently, core-needle biopsies are guided by external imaging modalities such as ultrasound imaging and x-ray computed tomography (CT) for breast and lung masses, respectively. These image-guided procedures are frequently limited by spatial resolution when using ultrasound imaging, or by temporal resolution (rapid real-time feedback capabilities) when using x-ray CT. One feasible approach is to perform OCT within small gauge needles to optically image tissue microstructure. However, to date, no system or core-needle device has been developed that incorporates both three-dimensional OCT imaging and tissue biopsy within the same needle for true OCT-guided core-needle biopsy. We have developed and demonstrate an integrated core-needle biopsy system that utilizes catheter-based 3-D OCT for real-time image-guidance for target tissue localization, imaging of tissue immediately prior to physical biopsy, and subsequent OCT imaging of the biopsied specimen for immediate assessment at the point-of-care. OCT images of biopsied ex vivo tumor specimens acquired during core-needle placement are correlated with corresponding histology, and computational visualization of arbitrary planes within the 3-D OCT volumes enables feedback on specimen tissue type and biopsy quality. These results demonstrate the potential for using real-time 3-D OCT for needle biopsy guidance by imaging within the needle and tissue during biopsy procedures.

Top