Benign Biliary Strictures: Diagnostic Evaluation and Approaches to Percutaneous Treatment.
Fidelman, Nicholas
2015-12-01
Interventional radiologists are often consulted to help identify and treat biliary strictures that can result from a variety of benign etiologies. Mainstays of noninvasive imaging for benign biliary strictures include ultrasound, contrast-enhanced computed tomography and magnetic resonance imaging, magnetic resonance cholangiopancreatography, and computed tomography cholangiography. Endoscopic retrograde cholangiography is the invasive diagnostic procedure of choice, allowing both localization of a stricture and treatment. Percutaneous biliary interventions are reserved for patients who are not candidates for endoscopic retrograde cholangiography (eg, history of distal gastrectomy and biliary-enteric anastomosis to a jejunal roux limb). This review discusses the roles of percutaneous transhepatic cholangiography and biliary drainage in the diagnosis of benign biliary strictures. The methodology for crossing benign biliary strictures, approaches to balloon dilation, management of recalcitrant strictures (ie, large-bore biliary catheters and retrievable covered stents), and the expected outcomes and complications of percutaneous treatment of benign biliary strictures are also addressed. Copyright © 2015 Elsevier Inc. All rights reserved.
Ogura, Takeshi; Takagi, Wataru; Kurisu, Yoshitaka; Higuchi, Kazuhide
2016-10-01
Endoscopic retrograde cholangiopancreatography (ERCP) is the gold-standard modality for diagnosis and therapy of bilio-pancreatic disease. In particular, peroral cholangiography (POCS) is a useful modality not only for diagnosing biliary disease, but also for therapeutic procedures such as electrohydraulic lithotripsy. The SPY-DS single-operator cholangioscope has recently become available, and offers favorable visualization, a wide view, suction function and a larger accessory working channel. However, if the duodenoscope cannot be advanced into the ampulla of Vater for reasons such as surgical anatomy, POCS cannot be performed. On the other hand, percutaneous transhepatic cholangiodrainage (PTCD) has been developed as an alternative endoscopic ultrasound-guided approach to the biliary tract. Peroral transluminal cholangioscopy (PTLC) using SPY-DS is a novel approach. Because transluminal interventional procedures under endoscopic ultrasound guidance have recently been developed, our technique may have clinical impact for selected cases. © 2016 Japanese Society of Hepato-Biliary-Pancreatic Surgery.
Reality named endoscopic ultrasound biliary drainage
Guedes, Hugo Gonçalo; Lopes, Roberto Iglesias; de Oliveira, Joel Fernandez; Artifon, Everson Luiz de Almeida
2015-01-01
Endoscopic ultrasound (EUS) is used for diagnosis and evaluation of many diseases of the gastrointestinal (GI) tract. In the past, it was used to guide a cholangiography, but nowadays it emerges as a powerful therapeutic tool in biliary drainage. The aims of this review are: outline the rationale for endoscopic ultrasound-guided biliary drainage (EGBD); detail the procedural technique; evaluate the clinical outcomes and limitations of the method; and provide recommendations for the practicing clinician. In cases of failed endoscopic retrograde cholangiopancreatography (ERCP), patients are usually referred for either percutaneous transhepatic biliary drainage (PTBD) or surgical bypass. Both these procedures have high rates of undesirable complications. EGBD is an attractive alternative to PTBD or surgery when ERCP fails. EGBD can be performed at two locations: transhepatic or extrahepatic, and the stent can be inserted in an antegrade or retrograde fashion. The drainage route can be transluminal, duodenal or transpapillary, which, again, can be antegrade or retrograde [rendezvous (EUS-RV)]. Complications of all techniques combined include pneumoperitoneum, bleeding, bile leak/peritonitis and cholangitis. We recommend EGBD when bile duct access is not possible because of failed cannulation, altered upper GI tract anatomy, gastric outlet obstruction, a distorted ampulla or a periampullary diverticulum, as a minimally invasive alternative to surgery or radiology. PMID:26504507
Ma, Kai; Huang, Xiao-bo; Xiong, Liu-lin; Xu, Qing-quan; Xu, Tao; Ye, Hai-yun; Yu, Lu-ping; Wang, Xiao-feng
2014-08-18
To evaluate the feasibility and efficacy of percutaneous renal puncture in percutaneous nephrolithotomy guided by novel needle-tracking ultrasound system. From may to october 2013, 16 cases of percutaneous nephrolithotomy were performed under the guidance of ultrasound system. The clinical data including the time of completing percutaneous renal puncture, the color of urine sucked out from the kidney calices, and the complications were analyzed retrospectively. Of the 16 patients, 18 percutaneous renal access were established guided by ultrasound system. All of them were successtul for the first time, and the average time of completing percutaneous renal punctures was (26.90 ± 11.37) s (15 to 54 s). After the operation, the hemoglobin decreased by (9.56 ± 5.27)%(1.41% to 24.06%), and no complications occurred except for postoperative fever in 2 case. The novel ultrasound system is a safe and effective technique that can reduce the technical difficulty of percutaneous renal puncture in percutaneous nephrolithotomy.
Chu, Carissa; Masic, Selma; Usawachintachit, Manint; Hu, Weiguo; Yang, Wenzeng; Stoller, Marshall; Li, Jianxing
2016-01-01
Abstract Ultrasound-guided renal access for percutaneous nephrolithotomy (PCNL) is a safe, effective, and low-cost procedure commonly performed worldwide, but a technique underutilized by urologists in the United States. The purpose of this article is to familiarize the practicing urologist with methods for ultrasound guidance for percutaneous renal access. We discuss two alternative techniques for gaining renal access for PCNL under ultrasound guidance. We also describe a novel technique of using the puncture needle to reposition residual stone fragments to avoid additional tract dilation. With appropriate training, ultrasound-guided renal access for PCNL can lead to reduced radiation exposure, accurate renal access, and excellent stone-free success rates and clinical outcomes. PMID:26414304
Xia, Ning; Gong, Ju; Lu, Jian; Chen, Zhi-Jin; Zhang, Li-Yun; Wang, Zhong-Min
2017-03-14
To assess the feasibility and effectiveness of a novel application of percutaneous intraductal radiofrequency (RF) for the treatment of biliary stent obstruction. We specifically report a retrospective study presenting the results of percutaneous intraductal RF in patients with biliary stent occlusion. A total of 43 cases involving biliary stent obstruction were treated by placing an EndoHPB catheter and percutaneous intraductal RF was performed to clean stents. The stent patency was evaluated by cholangiography and follow-up by contrast enhanced computed tomography or ultrasound after the removal of the drainage catheter. Following the procedures, of the 43 patients, 40 survived and 3 died with a median survival of 80.5 (range: 30-243) d. One patient was lost to follow-up. One patient had the stent patent at the time of last follow-up. Two patients with stent blockage at 35 d and 44 d after procedure underwent percutaneous transhepatic drain insertion only. The levels of bilirubin before and after the procedure were 128 ± 65 μmol/L and 63 ± 29 μmol/L, respectively. There were no related complications (haemorrhage, bile duct perforation, bile leak or pancreatitis) and all patients' stent patency was confirmed by cholangiography after the procedure, with a median patency time of 107 (range: 12-180) d. This preliminary clinical study demonstrated that percutaneous intraductal RF is safe and effective for the treatment of biliary stent obstruction, increasing the duration of stent patency, although randomized controlled trials are needed to confirm the effectiveness of this approach.
Xia, Ning; Gong, Ju; Lu, Jian; Chen, Zhi-Jin; Zhang, Li-Yun; Wang, Zhong-Min
2017-01-01
AIM To assess the feasibility and effectiveness of a novel application of percutaneous intraductal radiofrequency (RF) for the treatment of biliary stent obstruction. METHODS We specifically report a retrospective study presenting the results of percutaneous intraductal RF in patients with biliary stent occlusion. A total of 43 cases involving biliary stent obstruction were treated by placing an EndoHPB catheter and percutaneous intraductal RF was performed to clean stents. The stent patency was evaluated by cholangiography and follow-up by contrast enhanced computed tomography or ultrasound after the removal of the drainage catheter. RESULTS Following the procedures, of the 43 patients, 40 survived and 3 died with a median survival of 80.5 (range: 30-243) d. One patient was lost to follow-up. One patient had the stent patent at the time of last follow-up. Two patients with stent blockage at 35 d and 44 d after procedure underwent percutaneous transhepatic drain insertion only. The levels of bilirubin before and after the procedure were 128 ± 65 μmol/L and 63 ± 29 μmol/L, respectively. There were no related complications (haemorrhage, bile duct perforation, bile leak or pancreatitis) and all patients’ stent patency was confirmed by cholangiography after the procedure, with a median patency time of 107 (range: 12-180) d. CONCLUSION This preliminary clinical study demonstrated that percutaneous intraductal RF is safe and effective for the treatment of biliary stent obstruction, increasing the duration of stent patency, although randomized controlled trials are needed to confirm the effectiveness of this approach. PMID:28348491
Etienne, A-L; Audigié, F; Peeters, D; Gabriel, A; Busoni, V
2015-04-01
Cisternal puncture in dogs and cats is commonly carried out. This article describes the percutaneous ultrasound anatomy of the cisternal region in the dog and the cat and an indirect technique for ultrasound-guided cisternal puncture. Ultrasound images obtained ex vivo and in vivo were compared with anatomic sections and used to identify the landmarks for ultrasound-guided cisternal puncture. The ultrasound-guided procedure was established in cadavers and then applied in vivo in seven dogs and two cats. The anatomic landmarks for the ultrasound-guided puncture are the cisterna magna, the spinal cord, the two occipital condyles on transverse images, the external occipital crest and the dorsal arch of the first cervical vertebra on longitudinal images. Using these ultrasound anatomic landmarks, an indirect ultrasound-guided technique for cisternal puncture is applicable in the dog and the cat. © 2014 Blackwell Verlag GmbH.
Ultrasound-guided, percutaneous peripheral nerve stimulation: technical note.
Chan, Isaac; Brown, Anthony R; Park, Kenneth; Winfree, Christopher J
2010-09-01
Peripheral nerve stimulation is a form of neuromodulation that applies electric current to peripheral nerves to induce stimulation paresthesias within the painful areas. To report a method of ultrasound-guided, percutaneous peripheral nerve stimulation. This technique utilizes real-time imaging to avoid injury to adjacent vascular structures during minimally invasive placement of peripheral nerve stimulator electrodes. We describe a patient that presented with chronic, bilateral foot pain following multiple foot surgeries, for whom a comprehensive, pain management treatment strategy had failed. We utilized ultrasound-guided, percutaneous tibial nerve stimulation at a thigh level to provide durable pain relief on the right side, and open peripheral nerve stimulation on the left. The patient experienced appropriate stimulation paresthesias and excellent pain relief on the plantar aspect of the right foot with the percutaneous electrode. On the left side, we were unable to direct the stimulation paresthesias to the sole of the foot, despite multiple electrode repositionings. A subsequent, open placement of a left tibial nerve stimulator was performed. This revealed that the correct electrode position against the tibial nerve was immediately adjacent to the popliteal artery, and was thus not appropriate for percutaneous placement. We describe a method of ultrasound-guided peripheral nerve stimulation that avoids the invasiveness of electrode placement via an open procedure while providing excellent pain relief. We further describe limitations of the percutaneous approach when navigating close to large blood vessels, a situation more appropriately managed with open peripheral nerve stimulator placement. Ultrasound-guided placement may be considered for patients receiving peripheral nerve stimulators placed within the deep tissues, and not easily placed in a blind fashion.
Sconfienza, Luca Maria; Randelli, Filippo; Sdao, Silvana; Sardanelli, Francesco; Randelli, Pietro
2014-08-01
Calcific tendinopathy of the rotator cuff is a common condition. Ultrasound-guided percutaneous aspiration is one of several options to treat this condition. The main advantages of this procedure are short duration, good outcome, and low cost. Furthermore, only minor complications have been reported in the literature, namely, vagal reactions during the procedure and mild postprocedural pain. We report the first case of septic bursitis after ultrasound-guided percutaneous treatment of calcific tendinopathy. Although this is generally considered a very safe procedure, a risk of infection should be taken into account. Copyright © 2014 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.
Ultrasound-Guided Percutaneous Tenotomy of Biceps Tendon: Technical Feasibility on Cadavers.
Sconfienza, Luca Maria; Mauri, Giovanni; Messina, Carmelo; Aliprandi, Alberto; Secchi, Francesco; Sardanelli, Francesco; Randelli, Pietro Simone
2016-10-01
We tested the technical feasibility of ultrasound-guided percutaneous tenotomy of the long head of the biceps tendon (LHBT) in cadavers. Both shoulders of two fresh cadavers were scanned anteriorly to evaluate the extra-articular portion of the LHBT. Under ultrasound monitoring, a scalpel was advanced obliquely up to touch the superficial medial side of the LHBT, cutting it until the tendon was not visible anymore. Ultrasound evaluation was repeated after the procedure, and anatomic dissection was performed. The procedure was 100% feasible: four cuts were made to completely sever the tendon; the duration was less than 1 min. Skin incision measured 5 mm in two cases and 6 mm in two cases. Anatomic dissection confirmed complete tendon cut in all cases with proximal and distal tendon stumps very close to each other. Ultrasound-guided percutaneous LHBT tenotomy was 100% technically feasible in cadavers with a quick procedure and minimal cutaneous incision. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
ERIC Educational Resources Information Center
de Araújo Setin, Raíza; Fortes Cirimbelli, Carolina; Mazeto Ercolin, Anna Carolina; Pires, Sâmara Turbay; Disselli, Tamiris; Ferrarini Nunes Soares Hage, Maria Cristina
2018-01-01
The present study aimed to evaluate the applicability of artisanal simulators to teach veterinary and medical students the ultrasound-guided percutaneous biopsy using a tru-cut needle. The artisanal simulators consisted of bovine liver between two layers of commercially available grape gelatin. Students were paired, with one doing the biopsy and…
Huchzermeyer, H; Luska, G; Freuschmidt, J
1976-01-01
Percutaneous transjugular cholangiography (PTJC) is a new technique for visualization of the biliary duct system and for diagnosis of obstructive jaundice. First experiences of the authors in 22 patients are described. The advantages and disadvantages of this procedure, which at the present time is used rather rarely, are discussed and compared to various other cholangiographic methods. The endoscopic retrograde cholangiography (ERC) was used for patients with obstructive jaundice of unknown origine in the first place. If the biliary duct system could not be visualized by ERC (failure of complete obstruction of the common bile duct), the antegrade technique (PTJC) was performed. The peritoneoscopic and the transjugular cholangiography yield about the same percentage of positive results (90%), as far as visualization of the biliary tree is concerned. However in contrast to the peritoneoscopic methods PTJC seems to bear a smaller risk of complications. Some further diagnostic and therapeutical advantages, which might result from the use of PTJC are pointed out.
Shah, Amit; Best, Alistair J; Rennie, Winston J
2016-06-01
Various therapeutic options are available for treatment of recalcitrant plantar fasciitis. Studies using TOPAZ coblation (ArthroCare, Sunnyvale, CA) have had good early results. The current coblation technique involves a surgical incision or breach of the highly specialized plantar fat pad, which can be associated with risks. We describe a novel technique of ultrasound-guided percutaneous coblation with a lateral heel approach. Advantages include precise targeting of the plantar fascia by direct dynamic visualization of the coblation tip, a true percutaneous approach with a needle skin puncture (<5 mm), and preservation of the plantar fat pad by using a lateral heel approach. © 2016 by the American Institute of Ultrasound in Medicine.
Endoscopic Ultrasound-guided drainage of an abdominal fluid collection following Whipple’s resection
Jah, Asif; Jamieson, Neville; Huguet, Emmanuel; Griffiths, William; Carroll, Nicholas; Praseedom, Raaj
2008-01-01
Percutaneous aspiration and drainage of post-operative abdominal fluid collections is a well established standard technique. However, some fluid collections are not amenable to percutaneous drainage either due to location or the presence of surrounding visceral structures. Endoscopic Ultrasound (EUS) has been widely used for the drainage of pancreatitis-related abdominal fluid collections. However, there are no reports on the use of this technique in the post-operative setting. We report a case where the EUS-guided technique was used to drain a percutaneously inaccessible post-operative collection which had developed after Whipple’s resection. PMID:19058316
Ultrasound-Guided Percutaneous Drainage of Neonatal Pyometrocolpos Under Local Anesthesia
DOE Office of Scientific and Technical Information (OSTI.GOV)
Algin, Oktay, E-mail: droktayalgin@gmail.com; Erdogan, Cuneyt; Kilic, Nizamettin
2011-02-15
Hydrometrocolpos is an uncommon congenital disorder with cystic dilatation of the vagina and uterus that occurs as a result of accumulated secretions from the reproductive tract due to distal genital tract obstruction. Secondary infection may also occur, resulting in pyometrocolpos, a potentially lethal disease. Immediate drainage of the cystic mass in patients determined to have pyometrocolpos is required to prevent or treat uropathy and septicemia until definitive corrective surgery can be performed. We report an unusual cause of obstructive uropathy in three infants: pyometrocolpos due to lower genital tract atresia. Ultrasound-guided percutaneous drainage of the pyometrocolpos resulted in dramatically improvedmore » clinical and laboratory findings in these patients. Ultrasound-guided percutaneous drainage under local anesthesia is a simple, minimally invasive, safe, and effective procedure that facilitates later successful corrective surgery and avoids the need for more complex drainage procedures.« less
Arias-Buría, José L.; Truyols-Domínguez, Sebastián; Valero-Alcaide, Raquel; Salom-Moreno, Jaime; Atín-Arratibel, María A.; Fernández-de-las-Peñas, César
2015-01-01
Objective. To compare effects of ultrasound- (US-) guided percutaneous electrolysis combined with an eccentric exercise program of the rotator cuff muscles in subacromial pain syndrome. Methods. Thirty-six patients were randomized and assigned into US-guided percutaneous electrolysis (n = 17) group or exercise (n = 19) group. Patients were asked to perform an eccentric exercise program of the rotator cuff muscles twice every day for 4 weeks. Participants assigned to US-guided percutaneous electrolysis group also received the application of galvanic current through acupuncture needle on each session once a week (total 4 sessions). Shoulder pain (NPRS) and disability (DASH) were assessed at baseline, after 2 sessions, and 1 week after the last session. Results. The ANOVA revealed significant Group∗Time interactions for shoulder pain and disability (all, P < 0.01): individuals receiving US-guided percutaneous electrolysis combined with the eccentric exercises experienced greater improvement than those receiving eccentric exercise alone. Conclusions. US-guided percutaneous electrolysis combined with eccentric exercises resulted in small better outcomes at short term compared to when only eccentric exercises were applied in subacromial pain syndrome. The effect was statistically and clinically significant for shoulder pain but below minimal clinical difference for function. Future studies should investigate the long-term effects and potential placebo effect of this intervention. PMID:26649058
Laparoscopy-guided intracorporeal ultrasound accurately delineates hepatobiliary anatomy.
Yamamoto, M; Stiegmann, G V; Durham, J; Berguer, R; Oba, Y; Fujiyama, Y; McIntyre, R C
1993-01-01
The purpose of this study was to develop a technique and assess the ability of a laparoscopic ultrasound probe to delineate biliary antomy and to determine the presence or absence of duct stones. Five pigs had ultrasonography of biliary structures and liver at laparoscopy followed by cholangiograms and anatomical dissection. Five patients had ultrasonography of the biliary tract at laparoscopic cholecystectomy. All animals had adequate visualization of important hepatobiliary structure, and an optimal method of accessing these structures at laparoscopy was established. Patients had ultrasonography which used methods developed in the animal trial. All had adequate visualization of the entire common bile duct confirmed by cholangiography. Limitations in demonstrating the relationship of the cystic duct to the common duct were technical and can be corrected. Laparoscopic ultrasonography has significant potential for delineation of biliary anatomy and determination of presence or absence of duct calculi. Clinical implementation could minimize the risk of iatrogenic duct injury and the need for operative cholangiography.
Sharipov, V Sh
2000-01-01
Injection hepatography (IH) was made in 278 patients with cholestasis to study the drainage function of the liver. In 208 cases. IH was performed as a test during percutaneous transhepatic cholangiography (PTHC). The hepatic lymph pathways were imaged in 167 (60%) patients. Images of the biliary tract were obtained in 245 (88.1%) patients with cholestasis, it being not dilated in 34 (12.2%) patients. The fact that hepatolymphography may be performed during PTHC as an independent test permits verification of hepatic lymph circulatory disorders that are an index of the rate of inflammation in the organ.
Elizabethkingia Meningoseptica in a Case of Biliary Tract Infection Following Liver Transplantation
Musalem, Hebah M.; Honjol, Yazan N.; Tuleimat, Lin M.; Al Abbad, Saleh I.; Alsohaibani, Fahad I.
2017-01-01
Patient: Female, 55 Final Diagnosis: Percutaneous transhepatic cholangiography biliary drain infection with Elizabethkingia meningoseptica Symptoms: Right upper quadrant abdominal pain Medication: IV Ciprofloxacin 400 mg/12 hrs Clinical Procedure: None Specialty: Surgery and Internal Medicine Objective: Rare disease Background: Elizabethkingia meningoseptica (E. meningoseptica) is an aerobic Gram-negative bacillus known to thrive in moist environments, and is now recognized as a hospital-acquired infection, being found to contaminate hospital equipment, respiratory apparatus, hospital solutions, water, and drainage systems. Nosocomial infection with E. meningoseptica occurs in immunocompromised patients, requires specialized identification methods, and is resistant to conventional antibiotics. We report a case of E. meningoseptica infection arising from a percutaneous transhepatic biliary drainage (PTBD) tube. Case Report: A 55-year-old Saudi woman underwent liver transplantation. The post-operative period immediately following transplantation was complicated by anastomotic biliary stricture and bile leak, which was managed with percutaneous transhepatic cholangiography (PTC) with PTBD. She developed right upper quadrant abdominal pain, and her ultrasound (US) showed a sub-diaphragmatic collection. Microbial culture from the PTBD tube was positive for E. meningoseptica, which was treated with intravenous ciprofloxacin and metronidazole. This case is the second identified infection with E. meningoseptica at our specialist center, fifteen years after isolating the first case in a hemodialysis patient. We believe that this is the first case of E. meningoseptica infection to be reported in a liver transplant patient. Conclusions: The emerging nosocomial infectious organism, E. meningoseptica is being seen more often on hospital equipment and medical devices and in water. This case report highlights the need for awareness of this infection in hospitalized immunocompromised patients and the appropriate identification and management of infection with E. meningoseptica. PMID:28931801
The era of ultrasonography during laparoscopic cholecystectomy.
Onders, Raymond P; Hallowell, Peter T
2005-03-01
The use of ultrasound cholangiography during cholecystectomy has been well described. This study was undertaken to assess the use of the umbilical port exclusively for ultrasound and to assess its employment on the use of fluoroscopy resources. In addition, we also looked at the increased use of ultrasound from 2000 to 2004. The use of imaging techniques during all cholecystectomies was analyzed from January 2000 to July 2001 for one surgeon and compared with that surgeon's present use from January 2004 to June 2004. Patient demographics, intraoperative finding, and postoperative results were reviewed. During the first study period, ultrasound was used in 29% of 189 laparoscopic cholecystectomies. During 2004, ultrasound was used in 77% of 66 laparoscopic cholecystectomies. Throughout both periods, fluoroscopy was only used during 6 laparoscopic common bile duct explorations (2.4% of all cases). There were no false-positive or -negative ultrasounds, and there were no bile duct injuries. As experience with ultrasound cholangiography increases, there is little indication for fluoroscopic cholangiography except for rare questions concerning anatomy and during therapeutic maneuvers for common bile duct stones.
Radiography of the bile ducts: a symposium of the use of new modalities for diagnosis and treatment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Berk, R.N.; Cooperberg, P.L.; Gold, R.P.
1982-10-01
New diagnostic and therapeutic techniques have enabled the radiologist to assume a significant role in the management of jaundice, whereas before he was powerless to make any contribution at all. In this symposium, sonography, percutaneous transhepatic cholangiography, endoscopic retrograde cholangiography, and interventional procedures are analyzed and placed in perspective.
Usawachintachit, Manint; Tzou, David T; Mongan, John; Taguchi, Kazumi; Weinstein, Stefanie; Chi, Thomas
2017-02-01
Ultrasound-guided percutaneous nephrolithotomy (PCNL) has become increasingly utilized. Patients with nondilated collecting systems represent a challenge: the target calix is often difficult to visualize. Here we report pilot study results for retrograde ultrasound contrast injection to aid in percutaneous renal access during ultrasound-guided PCNL. From April to July 2016, consecutive patients over the age of 18 years with nondilated collecting systems on preoperative imaging who presented for PCNL were enrolled. B-mode ultrasound imaging was compared with contrast-enhanced mode with simultaneous retrograde injection of Optison™ via an ipsilateral ureteral catheter. Five patients (four males and one female) with renal stones underwent PCNL with retrograde ultrasound contrast injection during the study period. Mean body mass index was 28.3 ± 5.6 kg/m 2 and mean stone size was 24.5 ± 12.0 mm. Under B-mode ultrasound, all patients demonstrated nondilated renal collecting systems that appeared as hyperechoic areas, where it was difficult to identify a target calix for puncture. Retrograde contrast injection facilitated delineation of all renal calices initially difficult to visualize under B-mode ultrasound. Renal puncture was then performed effectively in all cases with a mean puncture time of 55.4 ± 44.8 seconds. All PCNL procedures were completed without intraoperative complications and no adverse events related to ultrasound contrast injection occurred. Retrograde ultrasound contrast injection as an aide for renal puncture during PCNL is a feasible technique. By improving visualization of the collecting system, it facilitates needle placement in challenging patients without hydronephrosis. Future larger scale studies comparing its use to standard ultrasound-guided technique will be required to validate this concept.
Kang, Bo-Sung; Lee, Seung Hak; Cho, Yung; Chung, Sun Gun
2016-08-01
Ultrasound-guided percutaneous barbotage is an effective treatment for rotator cuff calcific tendinopathy, providing rapid and substantial pain relief. We present the case of a 49-year-old woman with aggravated pain early after ultrasound-guided barbotage of a large calcific deposit in the supraspinatus tendon. Subsequent examination revealed a thick calcification spreading along the subacromial-subdeltoid bursa space, suggesting acute calcific bursitis complicated by barbotage. Additional barbotage alleviated her pain completely. Therefore, a high index of suspicion for acute calcific bursitis is required in patients with unresolved or aggravated pain after barbotage. Repeated barbotage could be effective for this condition. Copyright © 2016 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.
Transvaginal Ultrasound-Guided Biopsy of Deep Pelvic Masses: How We Do It.
Plett, Sara K; Poder, Liina; Brooks, Rebecca A; Morgan, Tara A
2016-06-01
The purpose of this review is to discuss the rationale and indications for transvaginal ultrasound-guided biopsy. Transvaginal ultrasound-guided biopsy can be a helpful tool for diagnosis and treatment planning in the evaluation of pelvic masses, particularly when the anatomy precludes a transabdominal or posterior transgluteal percutaneous biopsy approach. A step-by-step summary of the technique with preprocedure and postprocedure considerations is included. © 2016 by the American Institute of Ultrasound in Medicine.
Kissin, C M; Grundy, A
1987-01-01
Percutaneous transhepatic cholangiography (PTHC) is now a widely available, inexpensive investigation with a low incidence of complications, especially in the nonobstructed system, and a high success rate. Its role in the management of obstructive jaundice is well established but it is only infrequently performed in the investigation of persistent bile leakage following biliary tract surgery. Four cases are reported in which the superior demonstration of biliary anatomy provided by PTHC allowed successful identification of the site of postoperative biliary leakage. We compared PTHC with other diagnostic imaging techniques available and conclude that it is a safe, accurate, and reliable technique.
Ravi, Parli Raghavan; Vijai, M N; Shouche, Sachin
2017-01-01
In recent years ultrasound guided percutaneous tracheostomy (USPCT) has become a routine practice in critical care units. Its safety and superiority over conventional percutaneous tracheostomy and bronchoscopic guided PCT is proven to be non-inferior in elective cases. However its role in emergency percutaneous tracheostomy has never been studied, since percutaneous tracheostomy itself remains an enigma in accessing emergency airway. There is no report of use of ultrasound guided percutaneous tracheostomy in emergency setting so far in the literature. We report our early experience with USPCT in emergency setting. Sixteen adult patients who required access to an emergency surgical airway after failure to accomplish emergency oro-tracheal intubation were the study population. Their airway was accessed by USPCT. Recorded data included clinical and demographic data including time taken to perform the procedure and complications. Short term and long term follow ups for a period of 2 years were done for the survivors. Twelve male and four female patients underwent the procedure and the average time of the procedure was 3.6 min with no failures nor conversions to surgical tracheostomy and no complications. The average oxygen saturation was 86% and average Glasgow coma scale was 8.4. This time period included the oxygen insufflation time. 10 patients were decannulated while six patients died due to the pathology of the disease itself. There were no complications in either short term or long term follow up. USPCT has a definitive role in emergency both in trauma and non-trauma setting. It is safe, feasible and faster in experienced hands. Use of USPCT in emergency setting has further narrowed the list of contraindications of percutaneous tracheostomy.
Litz, Cristen N; Farach, Sandra M; Fernandez, Allison M; Elliott, Richard; Dolan, Jenny; Patel, Nikhil; Zamora, Lillian; Colombani, Paul M; Walford, Nebbie E; Amankwah, Ernest K; Snyder, Christopher W; Danielson, Paul D; Chandler, Nicole M
2017-06-01
Regional anesthesia is commonly used in children. Our hypothesis was that percutaneous ultrasound-guided (PERC) rectus sheath blocks would result in lower postoperative pain scores compared to intraoperative (IO) rectus sheath blocks following umbilical hernia repair. A single-institution randomized blinded trial was conducted in pediatric patients undergoing elective umbilical hernia repair. The primary outcome was mean postoperative Wong-Baker pain score. Secondary outcomes included narcotic requirements and length of postoperative stay. Fifty-eight patients were included: 28 PERC and 30 IO. Operating room time was significantly longer in the PERC group (41 vs. 35min, p<0.01). Mean postoperative pain scores (PERC-2.6 vs. IO-3.3, p=0.11), morphine equivalents intraoperatively (PERC-0 vs. IO-0.04mg/kg, p=0.29) and postoperatively (PERC-0.04 vs. IO-0.09mg/kg, p=0.17), time to first postoperative narcotic dose (PERC-30 vs. IO-22min, p=0.33, log-rank test), and postoperative length of stay (PERC-76 vs. IO-80min, p=0.44) were similar. Following umbilical hernia repair in children, percutaneous ultrasound-guided and intraoperative rectus sheath blocks resulted in similar mean postoperative pain scores. There were no differences in secondary outcomes such as time to first narcotic, narcotic requirements, and length of stay. The additional resources required to complete a percutaneous ultrasound-guided rectus sheath block may not be warranted. Randomized controlled trial. Level I. Copyright © 2017 Elsevier Inc. All rights reserved.
X-ray–free Ultrasound-guided Percutaneous Nephrolithotomy: How to Select the Right Patient?
Usawachintachit, Manint; Tzou, David T.; Hu, Weiguo; Li, Jianxing; Chi, Thomas
2017-01-01
OBJECTIVE To identify factors associated with successful ultrasound guidance for each surgical step of ultrasound-guided percutaneous nephrolithotomy (PCNL). PATIENTS AND METHODS Consecutive patients undergoing PCNL between March 2015 and June 2016 were prospectively enrolled. An attempt was made to use ultrasound guidance in renal access, tract dilation, and nephrostomy tube placement for each patient. For steps during which ultrasound guidance was unsuccessful, fluoroscopic screening was applied. Regression analysis identified patient characteristics associated with successful use of ultrasound guidance. RESULTS A total of 96 patients composed this cohort, with a mean body mass index of 28.7 kg/m2. Mean stone size was 33.1 ± 18.9 mm, and no hydronephrosis was found in 63.5% of cases. Fluoroscopic screening was required for renal access in 27 cases (28.1%), tract dilation in 38 (39.6%), and nephrostomy tube placement in 80 (83.3%). Multivariate analysis demonstrated that successful ultrasound guidance was significantly associated with the presence of hydronephrosis for renal access and the absence of staghorn calculi for tract dilation. Ultrasound-guided nephrostomy tube placement appeared linked to surgeon experience. CONCLUSION To achieve completely x-ray–free ultrasound-guided PCNL, the ideal patient should have a hydronephrotic collecting system with no staghorn stone present. For practitioners looking to adopt ultrasound guidance into their PCNL practice, these represent the most appropriate patients to safely initiate a surgical experience. PMID:27720776
Madan, Karan; Mittal, Saurabh; Hadda, Vijay; Jain, Deepali; Mohan, Anant; Guleria, Randeep
2016-01-01
Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a minimally invasive and safe technique for a sampling of mediastinal lesions. Indications for EBUS-TBNA have gradually expanded since its introduction. The usual approach to cytological sampling of the thyroid gland is percutaneous ultrasound-guided fine needle aspiration (US-FNA) performed under local anesthesia. US-FNA may be risky or not feasible in intrathoracic/substernal thyroid location. Feasibility of aspirating thyroid lesions with EBUS-TBNA has been occasionally reported. We report two patients wherein EBUS-TBNA was utilized for thyroid lesion aspiration and definitive diagnosis. We highlight the utility and safety of EBUS-TBNA in the evaluation of intrathoracic thyroid lesions wherein image-guided percutaneous aspiration may be risky/sometimes impossible to perform. A systematic review of literature has also been performed summarizing and discussing the issues pertaining to EBUS-TBNA of the thyroid gland. PMID:27891005
DOE Office of Scientific and Technical Information (OSTI.GOV)
Drinkovic, Ivan; Brkljacic, Boris
1996-09-15
Two cases with lethal complications are reported among 1750 ultrasound (US)-guided percutaneous fine-needle liver biopsies performed in our department. The first patient had angiosarcoma of the liver which was not suspected after computed tomography (CT) and US studies had been performed. The other patient had hepatocellular carcinoma in advanced hepatic cirrhosis. Death was due to bleeding in both cases. Pre-procedure laboratory tests did not reveal the existence of major bleeding disorders in either case. Normal liver tissue was interposed in the needle track between the liver capsule and the lesions which were targeted.
[Ultrasound guided percutaneous nephrolithotripsy].
Guliev, B G
2014-01-01
The study was aimed to the evaluation of the effectiveness and results of ultrasound guided percutaneous nephrolithotripsy (PNL) for the treatment of patients with large stones in renal pelvis. The results of PNL in 138 patients who underwent surgery for kidney stones from 2011 to 2013 were analyzed. Seventy patients (Group 1) underwent surgery with combined ultrasound and radiological guidance, and 68 patients (Group 2)--only with ultrasound guidance. The study included patients with large renal pelvic stones larger than 2.2 cm, requiring the formation of a single laparoscopic approach. Using the comparative analysis, the timing of surgery, the number of intra- and postoperative complications, blood loss and length of stay were evaluated. Percutaneous access was successfully performed in all patients. Postoperative complications (exacerbation of chronic pyelonephritis, gross hematuria) were observed in 14.3% of patients in Group 1 and in 14.7% of patients in Group 2. Bleeding requiring blood transfusion, and injuries of adjacent organs were not registered. Efficacy of PNL in the Group 1 was 95.7%; 3 (4.3%) patients required additional interventions. In Group 2, the effectiveness of PNL was 94.1%, 4 (5.9%) patients additionally underwent extracorporeal lithotripsy. There were no significant differences in the effectiveness of PNL, the volume of blood loss and duration of hospitalization. Ultrasound guided PNL can be performed in large pelvic stones and sufficient expansion of renal cavities, thus reducing radiation exposure of patients and medical staff.
Ultrasound-guided venous access for pacemakers and defibrillators.
Seto, Arnold H; Jolly, Aaron; Salcedo, Jonathan
2013-03-01
Ultrasound guidance is widely recommended to reduce the risk of complications during central venous catheter placement. However, ultrasound guidance is not commonly utilized for implanting leads for cardiac rhythm management devices. We describe our technique of ultrasound-guided pacemaker implantation, including a novel pull-through technique that allows percutaneous guidewire insertion prior to the first incision. We review the literature and recent advances in ultrasound imaging technology that may facilitate the adoption of ultrasound guidance. Ultrasound guidance provides a safe and rapid technique for extrathoracic subclavian or axillary venous lead placement. © 2012 Wiley Periodicals, Inc.
The value of percutaneous cholangiography
Evison, Gordon; McNulty, Myles; Thomson, Colin
1973-01-01
Percutaneous cholangiograms performed on fifty patients in a district general hospital have been reviewed, and the advantages and limitations of the examination are described. The investigation is considered to have sufficient diagnostic value to warrant its inclusion in the diagnostic armamentarium of every general radiological department. ImagesFig. 1Fig. 2Fig. 3Fig. 4 PMID:4788917
Nyman, R S; Cappelen-Smith, J; al Suhaibani, H; Alfurayh, O; Shakweer, W; Akhtar, M
1997-05-01
To compare the yield and complications of ultrasound-guided gun-biopsy and manual Tru-Cut techniques in percutaneous renal biopsy. A total of 448 biopsies were reviewed. They comprised 124 manual and 131 gun-biopsies in native kidneys, and 111 manual and 82 gun-biopsies in transplant kidneys. The gun-biopsies were performed under real-time ultrasound (US) guidance. The manual technique used US mainly for marking the position of the kidney. There was a significantly higher diagnostic yield and fewer complications in the gun-biopsy group. A total of 8 major complications were found, all in the manual group. Provided that the operator is experienced in US scanning, a switch from the manual technique to real-time US-guided gun-biopsy will result in the improvement of diagnostic accuracy together with a reduced risk of complications.
Whelehan, P; Vinnicombe, S J; Brown, D C; McLean, D; Evans, A
2014-08-01
To assess how accurately the sentinel lymph node (SLN) can be identified percutaneously, using gamma probe and ultrasound technology. Women with breast cancer, scheduled for wide local excision or mastectomy with SLN biopsy (SLNB), were included. Peri-areolar intradermal injection of technetium-99 nanocolloid was performed on the morning of surgery and 1-2 ml of blue dye was injected in the peri-areolar region once the patient was anaesthetized. Prior to surgery, a gamma probe was used over the skin to identify any hot spot that could represent a SLN. Ultrasound, guided by the hot spot, was then used to visualize potential SLNs and guide the insertion of a localizing wire. The accuracy in localizing the SLN by preoperative gamma-probe guided ultrasonography was assessed by comparison to SLNB. A SLN was correctly identified and marked using gamma-probe guided ultrasonography in 44 of 59 cases (75%; 95% CI: 63-86%). This study supports the case for investigating percutaneous gamma probe and ultrasound guided interventions in the axilla in women with breast cancer, as a potential alternative to surgical SLNB. Copyright © 2014 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Del Castillo-González, Federico; Ramos-Álvarez, Juan José; González-Pérez, José; Jiménez-Herranz, Elena; Rodríguez-Fabián, Guillermo
2016-10-01
Calcification of the medial collateral ligament (MCL) of the knee is rare. The literature reports no positive outcomes when conservative treatment has been followed. This paper reports a case of such calcification and its treatment using ultrasound-guided percutaneous lavage (UGPL). A 66-year-old patient presented with medial knee pain. X-ray, ultrasound, and magnetic resonance (MR) examinations revealed calcific bursitis of the MCL, which was treated by UGPL. One month after treatment the patient was asymptomatic. X-ray, ultrasound, and MR examinations confirmed the almost complete disappearance of the calcification; only very tiny fragments remained. Calcific bursitis of the MCL of the knee is very uncommon, but should be taken into account in differential diagnoses for medial knee pain. UGPL is proposed as a treatment for this condition.
Palliative percutaneous transhepatic drainage for inoperable obstructive jaundice.
Baxter-Smith, D. C.; Temple, J. G.; Howarth, F.
1982-01-01
A technique of percutaneous transhepatic drainage under local anaesthesia is described for the relief of intractable pruritus in patients with obstructive jaundice due to inoperable carcinoma. After standard percutaneous transhepatic cholangiography a polyethylene catheter is introduced into one of the large dilated bile ducts and left in situ, thereby establishing external retrograde biliary drainage. The technique has been used successfully in 6 cases with reduction in serum bilirubin levels and relief of pruritus. PMID:6182832
Assistive technology for ultrasound-guided central venous catheter placement.
Ikhsan, Mohammad; Tan, Kok Kiong; Putra, Andi Sudjana
2018-01-01
This study evaluated the existing technology used to improve the safety and ease of ultrasound-guided central venous catheterization. Electronic database searches were conducted in Scopus, IEEE, Google Patents, and relevant conference databases (SPIE, MICCAI, and IEEE conferences) for related articles on assistive technology for ultrasound-guided central venous catheterization. A total of 89 articles were examined and pointed to several fields that are currently the focus of improvements to ultrasound-guided procedures. These include improving needle visualization, needle guides and localization technology, image processing algorithms to enhance and segment important features within the ultrasound image, robotic assistance using probe-mounted manipulators, and improving procedure ergonomics through in situ projections of important information. Probe-mounted robotic manipulators provide a promising avenue for assistive technology developed for freehand ultrasound-guided percutaneous procedures. However, there is currently a lack of clinical trials to validate the effectiveness of these devices.
Okasha, Hussein Hassan; Naga, Mazen Ibrahim; Esmat, Serag; Naguib, Mohamed; Hassanein, Mohamed; Hassani, Mohamed; El-Kassas, Mohamed; Mahdy, Reem Ezzat; El-Gemeie, Emad; Farag, Ali Hassan; Foda, Ayman Mohamed
2013-01-01
Objective: Pancreatic carcinoma is one of the leading cancer morbidity and mortality world-wide. Controversy has arisen about whether the percutaneous approach with computed tomography/ultrasonography-guidance fine needle aspiration (US-FNA) or endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) is the preferred method to obtain diagnostic tissue. Our purpose of this study is to compare between the diagnostic accuracy of EUS-FNA and percutaneous US-FNA in diagnosis of pancreatic cancer. Patients and Methods: A total of 197 patients with pancreatic masses were included in the study, 125 patients underwent US-FNA (Group 1) and 72 patients underwent EUS-FNA (Group 2). Results: EUS-FNA has nearly the same accuracy (88.9%) as US-FNA (87.2%) in diagnosis of pancreatic cancer. The sensitivity, specificity, positive predictive value and negative predictive value for EUS-FNA was 84%, 100%, 100%, 73.3% respectively. It was 85.5%, 90.4%, 94.7%, 76% respectively for US-FNA. EUS-FNA had a lower complication rate (1.38%) than US-FNA (5.6%). Conclusion: EUS-FNA has nearly the same accuracy as US-FNA of pancreatic masses with a lower complication rate. PMID:24949394
Safety of pediatric percutaneous liver biopsy performed by interventional radiologists.
Potter, Carol; Hogan, Mark J; Henry-Kendjorsky, Katherine; Balint, Jane; Barnard, John A
2011-08-01
National data suggest that pediatric percutaneous liver biopsy is increasingly being performed by interventional radiologists rather than pediatric gastroenterologists. The objective of the present report is to describe the safety and effectiveness of percutaneous liver biopsy performed by interventional radiologists in a large cohort of children and to compare the results with the existing literature on biopsies performed by pediatric gastroenterologists. The medical records of 249 children undergoing ultrasound-guided percutaneous liver biopsy by interventional radiologists were reviewed for adverse events and success of obtaining tissue. Two hundred ninety-four biopsies were reviewed. There were no deaths. There were 2 instances of a 2-g or greater drop in hemoglobin following biopsy, neither of which was associated with clinical signs of hemorrhage. A small, asymptomatic pneumothorax quickly resolved without treatment. One patient developed Klebsiella sepsis 48 hours after biopsy. In all but 1 case, an adequate sample size was obtained. This low incidence of adverse events compares favorably with existing published reports of morbidity and mortality following percutaneous liver biopsy performed by pediatric gastroenterologists. Ultrasound-guided percutaneous liver biopsy performed by experienced pediatric interventional radiologists in a children's hospital setting is as safe and effective as biopsy performed by pediatric gastroenterologists.
Hai, Ning; Zhang, Jing; Xu, Ruifang; Han, Zhi-Yu; Liu, Fang Yi
2017-09-01
To evaluate the feasibility, safety and technical efficacy of ultrasound-guided percutaneous microwave ablation with artificial ascites for adenomyosis. Between May 2015 and May 2016, a total of 25 patients with symptomatic adenomyosis who underwent ultrasound-guided percutaneous microwave ablation with artificial ascites were included in this retrospective study. A matching cohort of 50 patients underwent ultrasound-guided percutaneous microwave ablation without artificial ascites as controls. The technical efficacy, complications and short-term treatment effectiveness were assessed and compared with the controls. Artificial ascites was successfully achieved in all of the 25 patients with the administration of a median of 550 mL (range, 250-1200 mL) of solution. There was substantial improvement in achieving a better antenna path in 100% (20/20) of the cases with a poor antenna path. The complete separation was achieved in 23 of 25 patients. The mean ablation time was 26.5 ± 7.3 min and the median non-perfusion volume ratio was 76% which was similar to the control group (p > .05). No serious complications were observed. Patient pain scores for dysmenorrhoea showed a statistically significant decline from the baseline of 6.71 ± 0.96 to 2.92 ± 0.79 and the symptom severity score declined statistically significantly from 21.8 ± 5.5 to 16.4 ± 4.8 at 3 months follow-up. Percutaneous microwave ablation with artificial ascites is feasible, safe and can be effective in improving access for treatment of adenomyosis.
[Mirizzi syndrome: experience at Spanish Hospital of Veracruz].
Roesch-Dietlen, Federico; Pérez-Morales, Alfonso Gerardo; Martínez-Fernández, Silvia; Remes-Troche, José María; Jiménez-García, Victoria Alejandra; Romero-Sierra, Graciela
2013-01-01
Mirizzi syndrome is a complication of gallbladder stones impacted in Hartmann's pouch or cystic duct with compression of the bile duct. The diagnosis is made by imaging studies, although most of them are found through intraoperative surgical findings. Treatment is cholecystectomy and bile duct restoration when needed. to analyze a series of cases of Mirizzi syndrome and compare the results with those published in the literature. We report 4 cases with Mirizzi syndrome in a cohort of 1,034 cases studied in the Hospital Español of Veracruz over 21 years. In our series the frequency of Mirizzi syndrome was 0.38%, the average age was 32.1 ± 58.4 years, 50% were male gender and 25% had jaundice with a demonstrable liver profile. In 1 case, ultrasound suggested Mirizzi syndrome and percutaneous cholangiography and computed tomography confirmed the diagnosis. All patients underwent laparoscopic cholecystectomy, and 2 transcystic cholangiographies were performed. One case was classified as Type I-A and three as type I-B. (Beltran and Csendes). The postoperative evolution was satisfactory in all and no mortality was presented. Mirizzi syndrome should be suspected in patients with gallstones who develop obstructive jaundice and it must be confirmed with imaging studies. The surgeon must take extreme precautions to avoid accidental injury to the bile ducts.
Srivastava, A; Gupta, P; Chaturvedi, S; Singh, P; Kapoor, R; Dubey, D; Kumar, A
2010-01-01
To assess the feasibility, safety and results of percutaneous nephrolithotomy (PNL) in ectopically located kidneys and in patients with musculoskeletal deformities. Thirteen such patients underwent PNL between June 2005 and May 2008. Mean stone size was 27.4 mm (16-37 mm). Six patients had severe kyphoscoliosis, 2 patients each had achondroplasia, cross-fused ectopia and pelvic ectopic kidney, and 1 patient had thoracic kidney. All had a preoperative CT scan of the abdomen. Preoperative ultrasound- or CT-guided percutaneous nephrostomy (PCN) was done in 10 patients. Three patients underwent laparoscopic-assisted PNL. All underwent standard PNL. The stone-free rate, complication rate and need for secondary intervention were evaluated. PNL was successfully completed in all. A second ultrasound-guided intraoperative puncture was required in 2 patients. Re-look PNL was required in 1 patient and the same patient later required shock wave lithotripsy for complete stone clearance. The remaining 12 patients (92.3%) were rendered stone-free in a single sitting. PNL is a feasible and effective modality in anomalous kidneys. Preoperative planning with CT and image-guided PCN is helpful in these situations. Laparoscopic-assisted PNL can be safely performed in patients where access to a renal collecting system by fluoroscopy or image-guided assistance (ultrasound or CT scan) is not possible. Copyright (c) 2010 S. Karger AG, Basel.
Ultrasound-guided, minimally invasive, percutaneous needle puncture treatment for tennis elbow.
Zhu, Jiaan; Hu, Bing; Xing, Chunyan; Li, Jia
2008-10-01
This report evaluates the efficacy of percutaneous needle puncture under sonographic guidance in treating lateral epicondylitis (tennis-elbow). Ultrasound-guided percutaneous needle puncture was performed on 76 patients who presented with persistent elbow pain. Under a local anesthetic and sonographic guidance, a needle was advanced into the calcification foci and the calcifications were mechanically fragmented. This was followed by a local injection of 25 mg prednisone acetate and 1% lidocaine. If no calcification was found then multiple punctures were performed followed by local injection of 25 mg prednisone acetate and 1% lidocaine. A visual analog scale (VAS) was used to evaluate the degree of pain pre-and posttreatment at 1 week to 24 weeks. Elbow function improvement and degree of self-satisfaction were also evaluated. Of the 76 patients, 55% were rated with excellent treatment outcome, 32% good, 11% average, and 3% poor. From 3 weeks posttreatment, VAS scores were significantly reduced compared with the pretreatment score (P<0.05) and continued to gradually decline up to 24 weeks posttreatment. Sonography demonstrated that the calcified lesions disappeared completely in 13% of the patients, were reduced in 61% of the patients, and did not change in 26% of the patients. Color Doppler flow signal used to assess hemodynamic changes showed a significant improvement after treatment in most patients. Ultrasound-guided percutaneous needle puncture is an effective and minimally invasive treatment for tennis elbow. Sonography can be used to accurately identify the puncture location and monitor changes.
Zhang, Catherine D; Erickson, Dana; Levy, Michael J; Gleeson, Ferga C; Salomao, Diva R; Delivanis, Danae A; Bancos, Irina
2017-12-01
While the left adrenal gland is readily accessible via endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA), data regarding the utility of EUS-FNA in the diagnosis of adrenal lesions remain limited. We aimed to ( 1) describe the clinical context, adverse event rate, and diagnostic performance of EUS-FNA, and ( 2) compare the safety profile and diagnostic accuracy of EUS-FNA with percutaneous adrenal biopsy. Single-center, retrospective cohort study. Medical records of patients who underwent adrenal EUS-FNA from 2005-2016 were reviewed. Biopsy outcomes were evaluated using a predefined reference standard. Results were compared to patients who underwent percutaneous biopsy (n = 419; 1994-2014) at the same institution. A total of 121 patients underwent EUS-FNA of 122 adrenal lesions (left [n = 121]; right [n = 1]; mean lesion size, 1.8 cm). Cytology was positive for malignancy in 35 (29%), suspicious for malignancy in 1 (1%), atypical in 1 (1%), negative for malignancy in 81 (66%), and nondiagnostic in 4 (3%). No adverse events were reported. EUS-FNA diagnosed metastasis with a sensitivity of 100%, specificity of 97.4%, positive predictive value of 91.7%, and negative predictive value of 100%. When compared to percutaneous biopsy, lesion size (1.8 cm vs. 3.7 cm; P<.001) and biopsy site (99% vs. 62% left adrenal; P<.001) were significantly different. EUS-FNA adverse event rate was lower than percutaneous biopsy (0% vs. 4%; P = .024), but nondiagnostic rates were similar (3.3% vs. 4.8%; P = .48). EUS-FNA is a sensitive technique to sample adrenal lesions in patients at high risk for adrenal metastasis with fewer adverse events compared to percutaneous biopsy. CI = confidence interval CT = computed tomography EUS-FNA = endoscopic ultrasound-guided fine-needle aspiration NPV = negative predictive value PPV = positive predictive value TUS = transabdominal ultra-sound.
Efficacy of ultrasound-guided percutaneous needle treatment of calcific tendinitis.
Vignesh, K Nithin; McDowall, Adam; Simunovic, Nicole; Bhandari, Mohit; Choudur, Hema N
2015-01-01
The purpose of this study was to conduct a systematic review of the efficacy of ultrasound-guided needle lavage in treating calcific tendinitis. Two independent assessors searched medical databases and screened studies for eligibility. Eleven articles were included. Heterogeneity among included studies precluded meta-analysis. Results of randomized controlled trials suggested no difference in pain relief between needle lavage and other interventions, but the studies were of low quality. Additional high-quality evidence is required to determine the relative efficacy of ultrasound-guided needle lavage in the management of calcific tendinitis of the rotator cuff.
Wang, Bin; Mintz, Gary S; Witzenbichler, Bernhard; Souza, Cristiano F; Metzger, D Christopher; Rinaldi, Michael J; Duffy, Peter L; Weisz, Giora; Stuckey, Thomas D; Brodie, Bruce R; Matsumura, Mitsuaki; Yamamoto, Myong-Hwa; Parvataneni, Rupa; Kirtane, Ajay J; Stone, Gregg W; Maehara, Akiko
2016-12-22
The impact of acute stent malapposition (ASM) on long-term clinical outcomes in patients undergoing percutaneous coronary intervention is still controversial. We sought to evaluate predictors and long-term clinical outcomes of ASM. ADAPT-DES (Assessment of Dual Antiplatelet Therapy With Drug-Eluting Stents) was a prospective multicenter study of 8663 patients undergoing percutaneous coronary intervention using drug-eluting stents. In a prespecified intravascular ultrasound-guided substudy, 2072 patients with 2446 culprit lesions had post-percutaneous coronary intervention intravascular ultrasound and were classified according to the presence or absence of ASM. After intravascular ultrasound-guided percutaneous coronary intervention, the overall prevalence of ASM after successful drug-eluting stents implantation was 14.4% per patient and 12.6% per lesion. Compared to lesions without ASM, lesions with ASM had larger in-stent lumen areas, larger stent areas, and larger in-stent vessel areas. A larger mean plaque area along with more attenuated plaque was observed in lesions with ASM versus lesions without ASM. Lesions with ASM had greater proximal and distal reference lumen areas and more distal, but not proximal, reference calcium compared to lesions without ASM. At 2-year follow-up, there was no significant difference in the incidence of cardiac death; myocardial infarction; early, late, or very late stent thrombosis; or clinically driven target lesion revascularization in patients with ASM versus those without ASM. Furthermore, ASM was not an independent predictor of 2-year major adverse cardiac events or target lesion revascularization even when forced into the multivariate model. In patients treated with intravascular ultrasound-guided drug-eluting stents implantation, ASM was not associated with adverse clinical events during long-term follow-up including, but not limited to, stent thrombosis. URL: https://www.clinicaltrials.gov. Unique identifier: NCT00638794. © 2016 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.
Adler, Ronald S.; Ciavarra, Gina A.; Pavlov, Helene
2006-01-01
Purpose To describe the procedure of ultrasound-guided Morton’s neuroma and recurrent stump neuroma injections and early clinical outcomes after a single injection. Materials and Methods Retrospective review of 44 percutaneous ultrasound-guided neuroma injections in 24 patients who had completed clinical outcomes questionnaires. A 10-point pain scale [scale of 1 (no pain) to 10 (severe pain)] in a 7-day pain log format was distributed to patients at the time percutaneous neuroma injection was performed. Results Neuromas were clearly visualized with sonography as hypoechoic nodules and were distinguishable from other causes of forefoot pain, such as metatarsophalangeal joint synovitis and intermetatarsal bursae. The sizes of the neuromas injected ranged between 4 and 19 mm. Postinjection, all neuromas displayed increased echogenicity and/or the appearance of fluid surrounding it, confirming localization of the therapeutic mixture. We arbitrarily subdivided the pain ratings into symptomatic (greater than 4) and asymptomatic (less than or equal to 4) for statistical analysis. Average pain level pre injection was 5.2 and average pain level was 3.7 at 7 days post single injection, with 62% of the initially symptomatic patients asymptomatic on day 7 (p < 0.000001). Overall, 76% of the total number of neuromas injected once were asymptomatic on day 7. Conclusion Ultrasound can be used to accurately target Morton’s neuromas and, therefore, appropriately direct therapeutic interventions, with good short-term clinical results. PMID:18751769
Usawachintachit, Manint; Masic, Selma; Allen, Isabel E.; Li, Jianxing
2016-01-01
Abstract Objectives: To define the learning curve associated with adopting ultrasound guidance for prone percutaneous nephrolithotomy (PCNL) for the experienced surgeon. Methods: A prospective cohort study of consecutive patients undergoing PCNL with ultrasound guidance for renal tract access and dilation was performed. Clinical data reviewed included success in gaining renal access with ultrasound guidance, total fluoroscopic screening time, and radiation exposure dose. PCNL cases performed with fluoroscopic guidance matched for stone size served as control cases. Results: One hundred consecutive ultrasound-guided procedures performed by a single experienced endourologist were divided into five experience groups. Significant improvement in renal access success rate with ultrasound was seen after 20 cases (p < 0.05). Total fluoroscopic screening time, radiation exposure dose, and operative time were also statistically significantly improved over the study period. When compared with fluoroscopy-guided PCNL, significant decreases in total fluoroscopic screening time (33.4 ± 35.3 seconds vs 157.5 ± 84.9 seconds, p < 0.05) and radiation exposure (7.0 ± 8.7 mGy vs 47.8 ± 45.9 mGy, p < 0.05) were seen. No differences in complication rates were found. Conclusions: Ultrasound-guided renal access for PCNL can be performed effectively after 20 cases. Transition to the use of ultrasound will quickly reduce radiation exposure for patients and intraoperative personnel. PMID:27150671
Uchinami, Yuka; Sakuraya, Fumika; Tanaka, Nobuhiro; Hoshino, Koji; Mikami, Eri; Ishikawa, Taro; Fujii, Hitomi; Ishikawa, Takehiko; Morimoto, Yuji
2017-05-01
Ultrasound-guided rectus sheath block and local anesthetic infiltration are the standard options to improve postoperative pain for children undergoing surgery with a midline incision. However, there is no study comparing the effect of ultrasound-guided rectus sheath block with local anesthetic infiltration for children undergoing laparoscopic surgery. The aim of this trial was to compare the onset of ultrasound-guided rectus sheath block with that of local anesthetic infiltration for laparoscopic percutaneous extraperitoneal closure in children. We performed an observer-blinded, randomized, prospective trial. Enrolled patients were assigned to either an ultrasound-guided rectus sheath block group or a local anesthetic infiltration group. The ultrasound-guided rectus sheath block group (n = 17) received ultrasound-guided rectus sheath block with 0.2 ml·kg -1 of 0.375% ropivacaine per side in the posterior rectus sheath compartment. The local anesthetic infiltration group (n = 17) received local anesthetic infiltration with 0.2 ml·kg -1 of 0.75% ropivacaine. The Face, Legs, Activity, Cry, and Consolability (FLACC) pain scores were recorded at 0, 30, 60 min after arrival at the postanesthesia care unit. Of the 37 patients enrolled in this study, 34 completed the study protocol. A significant difference in the pain scale between the ultrasound-guided rectus sheath block group and local anesthetic infiltration group was found at 0 min (median: 0, interquartile range [IQR]: 0-1.5, vs median: 1, IQR 0-5, confidence interval of median [95% CI]: 0-3, P = 0.048), but no significant difference was found at 30 min (median: 1, IQR: 0-4 vs median: 6, IQR: 0-7, 95% CI: 0-5, P = 0.061), or 60 min (median: 0, IQR: 0-2 vs median: 1, IQR: 0-3, 95% CI: -1 to 1, P = 0.310). No significant difference was found in anesthesia time between the ultrasound-guided rectus sheath block and local anesthetic infiltration groups. No procedure-related complications were observed in either group. Ultrasound-guided rectus sheath block is a quicker way to control postoperative pain for pediatric patients undergoing laparoscopic extraperitoneal closure than local anesthetic infiltration, and thus may provide a clinical benefit. © 2017 John Wiley & Sons Ltd.
[The ultrasonic diagnosis of jaundice. 199 cases (author's transl)].
Weill, F; Marmier, A; Paronneau, P; Zeltner, F; Charton, M N
1978-11-25
Thank to a thorough ultrasonographic analysis of biliary tree ("shotgun sign"), liver and pancreas, a positive diagnosis of obstruction was carried out in 92% of cases. The success rate in diagnosis of level of obstruction was also 92%. Aetiologic diagnosis was successful in 61% of cases only (almost 100% in jaundices of pancreatic origine). No false positive diagnosis of obstruction was made in non-obstructive jaundice. This enabled to carry out instrumental cholangiography (i.e. "skinny" needle percutaneous cholangiography, and ERC) only in case of clinical, biological and sonographic discrepancies, or in hilar obstructions.
Li, Teng-Fei; Huang, Guo-Hao; Li, Zhen; Hao, Chang-Fu; Ren, Jian-Zhuang; Duan, Xu-Hua; Zhang, Kai; Chen, Chen; Han, Xin-Wei; Jiao, De-Chao; Zhang, Meng-Fan; Wang, Yan-Li
2015-05-01
To determine the safety and feasibility of percutaneous transhepatic cholangiography (PTC) and intraductal radiofrequency (RF) ablation combined with biliary stent placement for malignant biliary obstruction. Data from patients with unresectable malignant biliary obstruction who underwent PTC, intraductal RF ablation, and biliary stent placement (n = 12) or PTC and biliary stent placement only (control group; n = 14) were reviewed. Postoperative complications, jaundice remission, and stent patency were assessed. All procedures were successful. No severe complications (eg, biliary bleeding, perforation) occurred. Two experimental group patients developed cholangitis, which resolved with conservative treatment. The 1-week jaundice remission and 3-month stent patency rates were similar in both groups, but the 6-month stent patency rate was higher in the experimental group (P < .05). In the experimental group, one death occurred as a result of gastrointestinal hemorrhage (unrelated to stent placement) by 3 months, and there were two cases of recurrent jaundice by 6 months. The latter two patients underwent repeat PTC, ablation, and stent placement. In the control group, one death occurred as a result of hepatic failure caused by progressive jaundice at 3 months, and another death resulted from disseminated intravascular coagulation caused by jaundice recurrence at 138 days after stent placement. In addition, seven patients developed jaundice recurrence (50-151 d after stent placement). PTC and repeat stent placement were performed in these patients. Percutaneous transhepatic cholangiography and intraductal RF ablation combined with biliary stent placement for malignant biliary obstruction is safe and feasible and effectively prolongs stent patency time. Copyright © 2015 SIR. Published by Elsevier Inc. All rights reserved.
Artifon, Everson L.A.; Loureiro, Jarbas F.; Baron, Todd H.; Fernandes, Kaie; Kahaleh, Michel; Marson, Fernando P.
2015-01-01
Background and Objectives: Endoscopic retrograde cholangiopancreatography (ERCP) is the method of choice for drainage in patients with distal malignant biliary obstruction, but it fails in up to 10% of cases. Percutaneous transhepatic cholangiography (PTC) and surgical bypass are the traditional drainage alternatives. This study aimed to compare technical and clinical success, quality of life, and survival of surgical biliary bypass or hepaticojejunostomy (HJT) and endoscopic ultrasound (EUS)-guided choledochoduodenostomy (CDT) in patients with distal malignant bile duct obstruction and failed ERCP. Patients and Methods: A prospective, randomized trial was conducted. From March 2011 to September 2013, 32 patients with malignant distal biliary obstruction and failed ERCP were studied. The HJT group consisted of 15 patients and the CDT group consisted of 14 patients. Technical and clinical success, quality of life, and survival were assessed prospectively. Results: Technical success was 94% (15/16) in the HJT group and 88% (14/16) in the CDT group (P = 0.598). Clinical success occurred in 14 (93%) patients in the HJT group and in 10 (71%) patients in the CDT group (P = 0.169). During follow-up, a statistically significant difference was seen in mean functional capacity scores, physical health, pain, social functioning, and emotional and mental health aspects in both techniques (P < 0.05). The median survival time in both groups was the same (82 days). Conclusion: Data relating to technical and clinical success, quality of life, and survival were similar in patients who underwent HJT and CDT drainage after failed ERCP for malignant distal biliary obstruction. PMID:26374583
López Ruiz, J A; Zabalza Estévez, I; Mieza Arana, J A
2016-01-01
To evaluate the possibility of determining the genetic profile of primary malignant tumors of the breast from specimens obtained by ultrasound-guided percutaneous biopsies during the diagnostic imaging workup. This is a retrospective study in 13 consecutive patients diagnosed with invasive breast cancer by B-mode ultrasound-guided 12 G core needle biopsy. After clinical indication, the pathologist decided whether the paraffin block specimens seemed suitable (on the basis of tumor size, validity of the sample, and percentage of tumor cells) before sending them for genetic analysis with the MammaPrint® platform. The size of the tumors on ultrasound ranged from 0.6cm to 5cm. In 11 patients the preserved specimen was considered valid and suitable for use in determining the genetic profile. In 1 patient (with a 1cm tumor) the pathologist decided that it was necessary to repeat the core biopsy to obtain additional samples. In 1 patient (with a 5cm tumor) the specimen was not considered valid by the genetic laboratory. The percentage of tumor cells in the samples ranged from 60% to 70%. In 11/13 cases (84.62%) it was possible to do the genetic analysis on the previously diagnosed samples. In most cases, regardless of tumor size, it is possible to obtain the genetic profile from tissue specimens obtained with ultrasound-guided 12 G core biopsy preserved in paraffin blocks. Copyright © 2015 SERAM. Published by Elsevier España, S.L.U. All rights reserved.
Fang, You-Qiang; Wu, Jie-Ying; Li, Teng-Cheng; Zheng, Hao-Feng; Liang, Guan-Can; Chen, Yan-Xiong; Hong, Xiao-Bin; Cai, Wei-Zhong; Zang, Zhi-Jun; Di, Jin-Ming
2017-06-01
This study aimed to assess the role of pre-designed route on computer tomography urography (CTU) in the ultrasound-guided percutaneous nephrolithotomy (PCNL) for renal calculus.From August 2013 to May 2016, a total of 100 patients diagnosed with complex renal calculus in our hospital were randomly divided into CTU group and control group (without CTU assistance). CTU was used to design a rational route for puncturing in CTU group. Ultrasound was used in both groups to establish a working trace in the operation areas. Patients' perioperative parameters and postoperative complications were recorded.All operations were successfully performed, without transferring to open surgery. Time of channel establishment in CTU group (6.5 ± 4.3 minutes) was shorter than the control group (10.0 ± 6.7 minutes) (P = .002). In addition, there was shorter operation time, lower rates of blood transfusion, secondary operation, and less establishing channels. The incidence of postoperative complications including residual stones, sepsis, severe hemorrhage, and perirenal hematoma was lower in CTU group than in control group.Pre-designing puncture route on CTU images would improve the puncturing accuracy, lessen establishing channels as well as improve the security in the ultrasound-guided PCNL for complex renal calculus, but at the cost of increased radiation exposure.
Percutaneous imaging-guided interventions for acute biliary disorders in high surgical risk patients
Donkol, Ragab Hani; Latif, Nahed Abdel; Moghazy, Khaled
2010-01-01
AIM: To evaluate the efficacy of percutaneous imaging-guided biliary interventions in the management of acute biliary disorders in high surgical risk patients. METHODS: One hundred and twenty two patients underwent 139 percutaneous imaging-guided biliary interventions during the period between January 2007 to December 2009. The patients included 73 women and 49 men with a mean age of 61 years (range 35-90 years). Fifty nine patients had acute biliary obstruction, 26 patients had acute biliary infection and 37 patients had abnormal collections. The procedures were performed under computed tomography (CT)- (73 patients), sonographic- (41 patients), and fluoroscopic-guidance (25 patients). Success rates and complications were determined. The χ2 test with Yates’ correction for continuity was applied to compare between these procedures. A P value < 0.05 was considered significant. RESULTS: The success rates for draining acute biliary obstruction under CT- , fluoroscopy- or ultrasound-guidance were 93.3%, 62.5% and 46.1%, respectively with significant P values (P = 0.026 and 0.002, respectively). In acute biliary infection, successful drainage was achieved in 22 patients (84.6%). The success rates in patients drained under ultrasound- and CT-guidance were 46.1% and 88.8%, respectively and drainage under CT-guidance was significantly higher (P = 0.0293). In 13 patients with bilomas, percutaneous drainage was successful in 11 patients (84.6%). Ten out of 12 cases with hepatic abscesses were drained with a success rate of 83.3%. In addition, the success rate of drainage in 12 cases with pancreatic pseudocysts was 83.3%. The reported complications were two deaths, four major and seven minor complications. CONCLUSION: Percutaneous imaging-guided biliary interventions help to promptly diagnose and effectively treat acute biliary disorders. They either cure the disorders or relieve sepsis and jaundice before operations. PMID:21160698
Endoscopic ultrasound-guided transmural drainage of postoperative pancreatic collections.
Tilara, Amy; Gerdes, Hans; Allen, Peter; Jarnagin, William; Kingham, Peter; Fong, Yuman; DeMatteo, Ronald; D'Angelica, Michael; Schattner, Mark
2014-01-01
Pancreatic leak is a major cause of morbidity after pancreatectomy. Traditionally, peripancreatic fluid collections have been managed by percutaneous or operative drainage. Data for endoscopic ultrasound (EUS)-guided drainage of postoperative fluid collections are limited. Here we report on the safety, efficacy, and timing of EUS-guided drainage of postoperative peripancreatic collections. This is a retrospective review of 31 patients who underwent EUS-guided drainage of fluid collections after pancreatic resection. Technical success was defined as successful transgastric deployment of at least one double pigtail plastic stent. Clinical success was defined as resolution of the fluid collection on follow-up CT scan and resolution of symptoms. Early drainage was defined as initial transmural stent placement within 30 days after surgery. Endoscopic ultrasound-guided drainage was performed effectively with a technical success rate of 100%. Clinical success was achieved in 29 of 31 patients (93%). Nineteen of the 29 patients (65%) had complete resolution of their symptoms and collection with the first endoscopic procedure. Repeat drainage procedures, including some with necrosectomy, were required in the remaining 10 patients, with eventual resolution of collection and symptoms. Two patients who did not achieve durable clinical success required percutaneous drainage by interventional radiology. Seventeen (55%) of 31 patients had successful early drainage completed within 30 days of their operation. Endoscopic ultrasound-guided drainage of fluid collections after pancreatic resection is safe and effective. Early drainage (<30 days) of postoperative pancreatic fluid collections was not associated with increased complications in this series. Copyright © 2014 American College of Surgeons. Published by Elsevier Inc. All rights reserved.
Osorio, Joseph A; Breshears, Jonathan D; Arnaout, Omar; Simon, Neil G; Hastings-Robinson, Ashley M; Aleshi, Pedram; Kliot, Michel
2015-09-01
OBJECT The objective of this study was to provide a technique that could be used in the preoperative period to facilitate the surgical exploration of peripheral nerve pathology. METHODS The authors describe a technique in which 1) ultrasonography is used in the immediate preoperative period to identify target peripheral nerves, 2) an ultrasound-guided needle electrode is used to stimulate peripheral nerves to confirm their position, and then 3) a methylene blue (MB) injection is performed to mark the peripheral nerve pathology to facilitate surgical exploration. RESULTS A cohort of 13 patients with varying indications for peripheral nerve surgery is presented in which ultrasound guidance, stimulation, and MB were used to localize and create a road map for surgeries. CONCLUSIONS Preoperative ultrasound-guided MB administration is a promising technique that peripheral nerve surgeons could use to plan and execute surgery.
'X-ray'-free balloon dilation for totally ultrasound-guided percutaneous nephrolithotomy.
Zhou, Tie; Chen, Guanghua; Gao, Xiaofeng; Zhang, Wei; Xu, Chuanliang; Li, Lei; Sun, Yinghao
2015-04-01
The objective of the study was to evaluate the feasibility and safety of balloon dilation for 'X-ray'-free ultrasound-guided percutaneous nephrolithotomy (PCNL). From January 2012 to December 2012, patients underwent 'X-ray'-free ultrasound-guided PCNL with Amplatz dilator (Group A). From January 2013 to April 2014, patients underwent 'X-ray'-free ultrasound-guided PCNL with balloon dilator (Group B). For balloon dilation, a 10 F fascial dilator was used to dilate the tract. Subsequently, the 6 F nephrostomy balloon (8 mm in diameter) was indwelled along the guidewire with a marked length equal to the dilation depth. Under the monitoring of ultrasound, the location of balloon was secured and disappearance of balloon waist was confirmed when the balloon was inflated at a pressure of 20 atm. A total of 163 patients were involved in this study. Of 81 procedures in Group A, 45 procedures were performed by a senior urologist while 36 procedures by a resident. Of 82 patients in Group B, 47 procedures were performed by the same senior urologist while 35 procedures by another resident. For the senior urologist, there was no statistically significant difference between two groups in calyx of entry, stone-free rate, decline of hemoglobin and hematocrit, operation time and hospitalization. But for the residents, there was less decline of hemoglobin and hematocrit, tract development time and hospitalization in Group B compared to Group A (0.6 vs. 1.7 g/dl, p = 0.001; 2.3% vs. 5.5%, p = 0.003; 10.1 vs. 11.0 min, p = 0.027; 7.8 vs. 13.9 days, p < 0.001). Balloon dilation method introduced in this study is compensable for tract development when 'X-ray'-free ultrasound-guided PCNL is performed. Modified techniques make totally ultrasound guidance for PCNL feasible, easy and safe. In addition, such a procedure is preferable for initial operators because of less hemorrhage complication.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miraglia, Roberto, E-mail: rmiraglia@ismett.edu; Maruzzelli, Luigi; Tuzzolino, Fabio
Purpose: The aim of this study was to estimate radiation exposure in pediatric liver transplants recipients who underwent biliary interventional procedures and to compare radiation exposure levels between biliary interventional procedures performed using an image intensifier-based angiographic system (IIDS) and a flat panel detector-based interventional system (FPDS). Materials and Methods: We enrolled 34 consecutive pediatric liver transplant recipients with biliary strictures between January 2008 and March 2013 with a total of 170 image-guided procedures. The dose-area product (DAP) and fluoroscopy time was recorded for each procedure. The mean age was 61 months (range 4-192), and mean weight was 17 kgmore » (range 4-41). The procedures were classified into three categories: percutaneous transhepatic cholangiography and biliary catheter placement (n = 40); cholangiography and balloon dilatation (n = 55); and cholangiography and biliary catheter change or removal (n = 75). Ninety-two procedures were performed using an IIDS. Seventy-eight procedures performed after July 2010 were performed using an FPDS. The difference in DAP between the two angiographic systems was compared using Wilcoxon rank-sum test and a multiple linear regression model. Results: Mean DAP in the three categories was significantly greater in the group of procedures performed using the IIDS compared with those performed using the FPDS. Statistical analysis showed a p value = 0.001 for the PTBD group, p = 0.0002 for the cholangiogram and balloon dilatation group, and p = 0.00001 for the group with cholangiogram and biliary catheter change or removal. Conclusion: In our selected cohort of patients, the use of an FPDS decreases radiation exposure.« less
Endoscopic ultrasound-guided biliary drainage
Chavalitdhamrong, Disaya; Draganov, Peter V
2012-01-01
Endoscopic ultrasound (EUS)-guided biliary drainage has emerged as a minimally invasive alternative to percutaneous and surgical interventions for patients with biliary obstruction who had failed endoscopic retrograde cholangiopancreatography (ERCP). EUS-guided biliary drainage has become feasible due to the development of large channel curvilinear therapeutic echo-endoscopes and the use of real-time ultrasound and fluoroscopy imaging in addition to standard ERCP devices and techniques. EUS-guided biliary drainage is an attractive option because of its minimally invasive, single step procedure which provides internal biliary decompression. Multiple investigators have reported high success and low complication rates. Unfortunately, high quality prospective data are still lacking. We provide detailed review of the use of EUS for biliary drainage from the perspective of practicing endoscopists with specific focus on the technical aspects of the procedure. PMID:22363114
Li, Xiao-long; Lu, Feng; Yue, Wen-wen; Sun, Li-ping; Bo, Xiao-wan; Guo, Le-hang; Xu, Jun-mei; Liu, Bo-ji; Li, Dan-dan; Qu, Shen
2016-01-01
Objective: To evaluate the therapeutic efficacy and safety of ultrasound-guided percutaneous bipolar radiofrequency ablation (BRFA) of benign thyroid nodules by comparison with a matched untreated control group. Methods: The therapeutic efficacy and safety in 35 patients who were subjected to a single session of ultrasound-guided percutaneous BRFA (Group A) for benign thyroid nodules were compared with those in 35 untreated patients (Group B) with benign nodules. The benign nature of all the nodules was confirmed by ultrasound-guided fine-needle aspiration biopsy (FNAB), and all the patients had normal thyroid functions. BRFA was performed with a bipolar electrode (CelonProSurge 150–T20) with an output power of 20 W. Nodule volume, thyroid function and clinical symptoms of all the patients were compared before treatment and during follow-up. Results: In Group A, the BRFA procedures were completed with a mean time of 10.02 ± 3.30 min (range, 5.47–16.03 min) and with a mean total energy deposition of 10.747 ± 3704 J (range, 5510–17.770 J). The procedures were tolerated well in all the patients without causing any major complications. At the 6-month follow-up, all of the nodule volume decreased significantly (from 8.81 ± 8.66 to 1.59 ± 1.55 ml, p < 0.001) in Group A, whereas the nodule volume increased from 6.90 ± 3.77 to 7.87 ± 3.95 ml in Group B (p < 0.001). All (100%) the 35 nodules in Group A had volume reduction ratios (VRRs) of >50%, among which 3 (8.57%) had VRRs >90%. In Group A, the clinical symptoms of the patients who had symptoms before BRFA disappeared, whereas in Group B, the patients had no resolution of clinical symptoms at the 6-month follow-up. Conclusion: Ultrasound-guided percutaneous BRFA seems to be an effective and safe method for the treatment of benign thyroid nodules. It may gain a wide use in clinical practice. Advances in knowledge: Based on the comparable efficacy and clinical symptoms between the BRFA and untreated groups, the technique of BRFA can be used as an effective and safe method for the treatment of benign thyroid nodules. PMID:26800232
Ultrasound-guided cable-free 13-gauge vacuum-assisted biopsy of non-mass breast lesions
Seo, Jiwoon; Jang, Mijung; Yun, Bo La; Lee, Soo Hyun; Kim, Eun-Kyu; Kang, Eunyoung; Park, So Yeon; Moon, Woo Kyung; Choi, Hye Young; Kim, Bohyoung
2017-01-01
Purpose To compare the outcomes of ultrasound-guided core biopsy for non-mass breast lesions by the novel 13-gauge cable-free vacuum-assisted biopsy (VAB) and by the conventional 14-gauge semi-automated core needle biopsy (CCNB). Materials and methods Our institutional review board approved this prospective study, and all patients provided written informed consent. Among 1840 ultrasound-guided percutaneous biopsies performed from August 2013 to December 2014, 145 non-mass breast lesions with suspicious microcalcifications on mammography or corresponding magnetic resonance imaging finding were subjected to 13-gauge VAB or 14-gauge CCNB. We evaluated the technical success rates, average specimen numbers, and tissue sampling time. We also compared the results of percutaneous biopsy and final surgical pathologic diagnosis to analyze the rates of diagnostic upgrade or downgrade. Results Ultrasound-guided VAB successfully targeted and sampled all lesions, whereas CCNB failed to demonstrate calcification in four (10.3%) breast lesions with microcalcification on specimen mammography. The mean sampling time were 238.6 and 170.6 seconds for VAB and CCNB, respectively. No major complications were observed with either method. Ductal carcinoma in situ (DCIS) and atypical ductal hyperplasia (ADH) lesions were more frequently upgraded after CCNB (8/23 and 3/5, respectively) than after VAB (2/26 and 0/4, respectively P = 0.028). Conclusion Non-mass breast lesions were successfully and accurately biopsied using cable-free VAB. The underestimation rate of ultrasound-detected non-mass lesion was significantly lower with VAB than with CCNB. Trial registration CRiS KCT0002267. PMID:28628656
[Percutaneous cholangiography: Chiba method, a diagnostic advance].
Correia, R A; Sampaio, R N; Soares, A C; Feijó, S G; Pessoa, J B
1979-01-01
Employing percutaneous transhepatic cholangiography by CHIBA method in 15 patients, it was possible to visualize biliary system in 93.3% of the cases. The radiologic diagnostic of KLATSKIN tumor was observed in 2 cases, 4 cases of carcinoma of the papila of VATER, 1 case of carcinoma of the terminal choledochus, 1 case of intrahepatic neoplasia, 1 case of stenosis secondary to choledocal, trauma, and in another it was damaged by subcapsular hepatic leakage of contrast. The complications were minor. In 5 cases the patients had biliary colic at the time of the exam. In 2 cases, signals of baeteremia occurred in the day following the exam, and in 4 cases there was a small subcapsular hepatic leakage of contrast. In one case it was encountered hematoma under the capsule of the liver, during surgery. The diagnosis was confirmed at surgery in 12 cases. We concluded that the simplicity of the technic, its low cost and its diagnostic, accuracy have made it extremely useful.
Mattiussi, Gabriele; Moreno, Carlos
2016-01-01
Proximal Hamstring Tendinopathy-related Sciatic Nerve Entrapment (PHTrSNE) is a neuropathy caused by fibrosis interposed between the semimembranosus tendon and the sciatic nerve, at the level of the ischial tuberosity. Ultrasound-guided Intratissue Percutaneous Electrolysis (US-guided EPI) involves galvanic current transfer within the treatment target tissue (fibrosis) via a needle 0.30 to 0.33 mm in diameter. The galvanic current in a saline solution instantly develops the chemical process of electrolysis, which in turn induces electrochemical ablation of fibrosis. In this article, the interventional procedure is presented in detail, and both the strengths and limits of the technique are discussed. US-guided EPI eliminates the fibrotic accumulation that causes PHTrSNE, without the semimembranosus tendon or the sciatic nerve being directly involved during the procedure. The technique is however of limited use in cases of compression neuropathy. US-guided EPI is a technique that is quick to perform, minimally invasive and does not force the patient to suspend their activities (work or sports) to make the treatment effective. This, coupled to the fact that the technique is generally well-tolerated by patients, supports use of US-guided EPI in the treatment of PHTrSNE.
Ultrasound-guided percutaneous bone drilling for the treatment of lateral epicondylitis.
Yoo, Sang Ho; Cha, Jang Gyu; Lee, Bo Ra
2018-01-01
To determine the clinical efficacy of sonographically-guided percutaneous bone drilling of the lateral epicondyle (LE) for the treatment of patients with LE. We included 24 patients with LE who reported pain in this study. All patients underwent sonographically-guided percutaneous bone drilling of the lateral epicondyle. Follow-up sonography and physical examinations were performed 1, 3 and 6 months after the procedure. The outcome measures included sonographic findings, visual analogue scale (VAS) score, maximum voluntary grip strength (MVGS) and patient-related tennis elbow evaluation (PRTEE) score. None of the patients had immediate complications during the procedure. The area of the extensor carpi radialis brevis (ECRB) tears decreased significantly at 1 month and declined gradually over the remaining 5 months of the study (p < 0.001). The mean pain VAS score was significantly lower at 6 months than preoperatively (respectively; p < 0.001). The mean MVGS increased significantly between pretreatment and 6 months post-treatment (p < 0.001), whereas the PRTEE score decreased significantly during the same period (p < 0.001). Sonographically-guided percutaneous drilling is a quick and safe treatment option for LE that can be performed in an outpatient setting. • Percutaneous drilling of the lateral condyle is effective for the treatment of LE. • The area of ECRB tears can be measured by US-guided saline injection. • US-guided percutaneous drilling is a quick and safe treatment option for LE.
Li, Xiang; Long, Qingzhi; Chen, Xingfa; He, Dalin; He, Hui
2017-04-01
SonixGPS is a novel real-time ultrasonography navigation technology, which has been demonstrated to promote accuracy of puncture in surgical operations. The aim of this study is to evaluate its application in guiding the puncture during percutaneous nephrolithotomy (PCNL). We retrospectively reviewed our experience in treating a total of 74 patients with complex kidney stones with PCNL, in which puncture in 37 cases were guided by SonixGPS system, while the other 37 by conventional ultrasound. The effectiveness of operation was evaluated in terms of stone clearance rate, operation time, time to successful puncture, number of attempts for successful puncture and hospital stay. The safety of operation was examined by evaluating postoperative complications. Our retrospective review showed that although there were no significant differences in stone clearance rates between the groups, SonixGPS guidance resulted in more puncture accuracy with shorter puncture time and higher successful puncture rate. Under the help of SonixGPS, most patients (92 %) had no or just mild complications, compared to that (73 %) in conventional ultrasound group. Post-operative decrease of hemoglobin in SonixGPS group was 13.79 (7-33) mg/dl, significantly lower than that 20.97 (8-41) mg/dl in conventional ultrasound group. Our experience demonstrates that SonixGPS is superior to conventional ultrasound in guiding the puncture in PCNL for the treatment of complex kidney stone.
Xu, Youming; Wu, Zhonghua; Yu, Jianhua; Wang, Shulong; Li, Fang; Chen, Jiushun; Liu, Jin; Chen, Kan
2012-06-01
To report our experience and assess the safety and efficacy of Doppler ultrasound-guided percutaneous nephrolithotomy (PCNL) with 2-step tract dilation for complex renal stones. From March 2009 to February 2011, 262 patients underwent PCNL. Eighty-three patients had a complete and 105 had partial staghorn calculus, and 74 had a renal pelvic stone of >2 cm in diameter. Thirty-five patients had renal surgical history. Doppler ultrasound-guided PCNL with 2-step tract dilation were performed. Stones were fragmented and cleared using a combination of ultrasonic and pneumatic lithotripters. All PCNL procedures were successful. Successful access to the collecting system was 100%. Although most of the cases (231/262) were managed satisfactorily by a single tract, a second tract was used in 31 cases. Mean operation time was 56 minutes (range 25-145). The primary stone-free rate of PCNL was 80.9%. There were 39 auxiliary procedures (13 second PCNL and 26 extracorporeal shock wave lithotripsy). One month after treatment, the overall stone-free rate was 92.7%. Five patients (1.9%) received blood transfusion. Eight patients (3.1%) with a postoperative fever of ≥38.5°C were cured by intravenous antibiotics. No other severe complications occurred. The mean postoperative stay was 3.8 days (range 2-12). Doppler ultrasound-guided PCNL with 2-step tract dilation for complex renal stones is safe, effective, and worthy of wider use in clinical practice. Copyright © 2012 Elsevier Inc. All rights reserved.
Bronchobiliary fistula and cholangiocarcinoma: a case report and principles of management.
Delande, S; Goffette, P; Verbaandert, C; Rahier, J; Graux, C; Mazzeo, F; Humblet, Y; Machiels, J P
2007-01-01
A 64-year-old woman was admitted with fever and cough. At admission, she had jaundice, hepatomegaly, and green-stained sputum. Computed tomography (CT) showed an intrahepatic abscess located near the dome, multiple hepatic metastases, biliary tract dilatation, and a right pleural effusion. Percutaneous transhepatic cholangiography demonstrated a communication between the intrahepatic biliary ducts and the bronchial tree. The patient was treated with antibiotic therapy, pleural and biliary drainages and a percutaneous drainage of the hepatic abscess.
Bo, Xiao-Wan; Xu, Hui-Xiong; Wang, Dan; Guo, Le-Hang; Sun, Li-Ping; Li, Xiao-Long; Zhao, Chong-Ke; He, Ya-Ping; Liu, Bo-Ji; Li, Dan-Dan; Zhang, Kun
2016-11-01
To investigate the usefulness of fusion imaging of contrast-enhanced ultrasound (CEUS) and CECT/CEMRI before percutaneous ultrasound-guided radiofrequency ablation (RFA) for liver cancers. 45 consecutive patients with 70 liver lesions were included between March 2013 and October 2015, and all the lesions were identified on CEMRI/CECT prior to inclusion in the study. Planning ultrasound for percutaneous RFA was performed using conventional ultrasound, ultrasound-CECT/CEMRI and CEUS and CECT/CEMRI fusion imaging during the same session. The numbers of the conspicuous lesions on ultrasound and fusion imaging were recorded. RFA was performed according to the results of fusion imaging. Complete response (CR) rate was calculated and the complications were recorded. On conventional ultrasound, 25 (35.7%) of the 70 lesions were conspicuous, whereas 45 (64.3%) were inconspicuous. Ultrasound-CECT/CEMRI fusion imaging detected additional 24 lesions thus increased the number of the conspicuous lesions to 49 (70.0%) (70.0% vs 35.7%; p < 0.001 in comparison with conventional ultrasound). With the use of CEUS and CECT/CEMRI fusion imaging, the number of the conspicuous lesions further increased to 67 (95.7%, 67/70) (95.7% vs 70.0%, 95.7% vs 35.7%; both p < 0.001 in comparison with ultrasound and ultrasound-CECT/CEMRI fusion imaging, respectively). With the assistance of CEUS and CECT/CEMRI fusion imaging, the confidence level of the operator for performing RFA improved significantly with regard to visualization of the target lesions (p = 0.001). The CR rate for RFA was 97.0% (64/66) in accordance to the CECT/CEMRI results 1 month later. No procedure-related deaths and major complications occurred during and after RFA. Fusion of CEUS and CECT/CEMRI improves the visualization of those inconspicuous lesions on conventional ultrasound. It also facilitates improvement in the RFA operators' confidence and CR of RFA. Advances in knowledge: CEUS and CECT/CEMRI fusion imaging is better than both conventional ultrasound and ultrasound-CECT/CEMRI fusion imaging for lesion visualization and improves the operator confidence, thus it should be recommended to be used as a routine in ultrasound-guided percutaneous RFA procedures for liver cancer.
Bo, Xiao-Wan; Wang, Dan; Guo, Le-Hang; Sun, Li-Ping; Li, Xiao-Long; Zhao, Chong-Ke; He, Ya-Ping; Liu, Bo-Ji; Li, Dan-Dan; Zhang, Kun
2016-01-01
Objective: To investigate the usefulness of fusion imaging of contrast-enhanced ultrasound (CEUS) and CECT/CEMRI before percutaneous ultrasound-guided radiofrequency ablation (RFA) for liver cancers. Methods: 45 consecutive patients with 70 liver lesions were included between March 2013 and October 2015, and all the lesions were identified on CEMRI/CECT prior to inclusion in the study. Planning ultrasound for percutaneous RFA was performed using conventional ultrasound, ultrasound-CECT/CEMRI and CEUS and CECT/CEMRI fusion imaging during the same session. The numbers of the conspicuous lesions on ultrasound and fusion imaging were recorded. RFA was performed according to the results of fusion imaging. Complete response (CR) rate was calculated and the complications were recorded. Results: On conventional ultrasound, 25 (35.7%) of the 70 lesions were conspicuous, whereas 45 (64.3%) were inconspicuous. Ultrasound-CECT/CEMRI fusion imaging detected additional 24 lesions thus increased the number of the conspicuous lesions to 49 (70.0%) (70.0% vs 35.7%; p < 0.001 in comparison with conventional ultrasound). With the use of CEUS and CECT/CEMRI fusion imaging, the number of the conspicuous lesions further increased to 67 (95.7%, 67/70) (95.7% vs 70.0%, 95.7% vs 35.7%; both p < 0.001 in comparison with ultrasound and ultrasound-CECT/CEMRI fusion imaging, respectively). With the assistance of CEUS and CECT/CEMRI fusion imaging, the confidence level of the operator for performing RFA improved significantly with regard to visualization of the target lesions (p = 0.001). The CR rate for RFA was 97.0% (64/66) in accordance to the CECT/CEMRI results 1 month later. No procedure-related deaths and major complications occurred during and after RFA. Conclusion: Fusion of CEUS and CECT/CEMRI improves the visualization of those inconspicuous lesions on conventional ultrasound. It also facilitates improvement in the RFA operators' confidence and CR of RFA. Advances in knowledge: CEUS and CECT/CEMRI fusion imaging is better than both conventional ultrasound and ultrasound-CECT/CEMRI fusion imaging for lesion visualization and improves the operator confidence, thus it should be recommended to be used as a routine in ultrasound-guided percutaneous RFA procedures for liver cancer. PMID:27626506
Training for percutaneous renal access on a virtual reality simulator.
Zhang, Yi; Yu, Cheng-fan; Liu, Jin-shun; Wang, Gang; Zhu, He; Na, Yan-qun
2013-01-01
The need to develop new methods of surgical training combined with advances in computing has led to the development of virtual reality surgical simulators. The PERC Mentor(TM) is designed to train the user in percutaneous renal collecting system access puncture. This study aimed to validate the use of this kind of simulator, in percutaneous renal access training. Twenty-one urologists were enrolled as trainees to learn a fluoroscopy-guided percutaneous renal accessing technique. An assigned percutaneous renal access procedure was immediately performed on the PERC Mentor(TM) after watching instruction video and an analog operation. Objective parameters were recorded by the simulator and subjective global rating scale (GRS) score were determined. Simulation training followed and consisted of 2 hours daily training sessions for 2 consecutive days. Twenty-four hours after the training session, trainees were evaluated performing the same procedure. The post-training evaluation was compared to the evaluation of the initial attempt. During the initial attempt, none of the trainees could complete the appointed procedure due to the lack of experience in fluoroscopy-guided percutaneous renal access. After the short-term training, all trainees were able to independently complete the procedure. Of the 21 trainees, 10 had primitive experience in ultrasound-guided percutaneous nephrolithotomy. Trainees were thus categorized into the group of primitive experience and inexperience. The total operating time and amount of contrast material used were significantly lower in the group of primitive experience versus the inexperience group (P = 0.03 and 0.02, respectively). The training on the virtual reality simulator, PERC Mentor(TM), can help trainees with no previous experience of fluoroscopy-guided percutaneous renal access to complete the virtual manipulation of the procedure independently. This virtual reality simulator may become an important training and evaluation tool in teaching fluoroscopy-guided percutaneous renal access.
Biliary tract obstruction secondary to cancer: management guidelines and selected literature review.
Lokich, J J; Kane, R A; Harrison, D A; McDermott, W V
1987-06-01
Malignant biliary tract obstruction (MBTO) due to either primary biliary tract cancer or metastasis to the porta hepatis is a common clinical problem. The most common metastatic tumors causing MBTO in order of frequency are gastric, colon, breast, and lung cancers. Radiographic diagnostic procedures should proceed in a cost-effective sequence from ultrasonography, computerized tomography (CT), percutaneous transhepatic cholangiography (PTHC), and endoscopic retrograde pancreatography with the goal of establishing the site of the biliary tract obstruction. The identification of the site of obstruction could be established by ultrasound 70% to 80%, CT scan 80% to 90%, PTHC 100%, and endoscopic retrograde cholangiography (ERCP) 85%. Therapeutic intervention by radiographic decompression (PTHC or endoscopic prosthesis), surgical bypass, or radiation therapy with or without chemotherapy may be selectively used based on (1) the site of obstruction; (2) the type of primary tumor; and (3) the presence of specific symptoms related to the obstruction. ("Prophylactic" biliary tract decompression to prevent ascending cholangitis is not supported by the literature in that the frequency of sepsis in the face of malignant obstruction is small (in contrast to sepsis associated with stone disease). Furthermore, PTHC with drainage as a long-term procedure is associated with a substantial frequency of sepsis and is unnecessary and possibly problematic as a preoperative procedure simply to reduce the bilirubin level. The use of radiation therapy in conjunction with chemotherapy for patients not deemed suitable for a surgical bypass because of the presence of proximal obstruction is an important alternative to PTHC.
Percutaneous Ultrasound-Guided Carpal Tunnel Release: Study Upon Clinical Efficacy and Safety
DOE Office of Scientific and Technical Information (OSTI.GOV)
Petrover, David, E-mail: dpetrover@yahoo.fr; Silvera, Jonathan, E-mail: silvera.jonathan@gmail.com; Baere, Thierry De, E-mail: Debaere@igr.fr
ObjectivesTo evaluate the feasibility and 6 months clinical result of sectioning of the transverse carpal ligament (TCL) and median nerve decompression after ultra-minimally invasive, ultrasound-guided percutaneous carpal tunnel release (PCTR) surgery.MethodsConsecutive patients with carpal tunnel syndrome were enrolled in this descriptive, open-label study. The procedure was performed in the interventional radiology room. Magnetic resonance imaging was performed at baseline and 1 month. The Boston Carpal Tunnel Questionnaire was administered at baseline, 1, and 6 months.Results129 patients were enrolled. Significant decreases in mean symptom severity scores (3.3 ± 0.7 at baseline, 1.7 ± 0.4 at Month 1, 1.3 ± 0.3 at Month 6) and mean functional status scores (2.6 ± 1.1 atmore » baseline, 1.6 ± 0.4 at Month 1, 1.3 ± 0.5 at Month 6) were noted. Magnetic resonance imaging showed a complete section of all TCL and nerve decompression in 100% of patients. No complications were identified.ConclusionsUltrasound-guided PCTR was used successfully to section the TCL, decompress the median nerve, and reduce self-reported symptoms.« less
Mattiussi, Gabriele; Moreno, Carlos
2016-01-01
Summary Background Proximal Hamstring Tendinopathy-related Sciatic Nerve Entrapment (PHTrSNE) is a neuropathy caused by fibrosis interposed between the semimembranosus tendon and the sciatic nerve, at the level of the ischial tuberosity. Methods Ultrasound-guided Intratissue Percutaneous Electrolysis (US-guided EPI) involves galvanic current transfer within the treatment target tissue (fibrosis) via a needle 0.30 to 0.33 mm in diameter. The galvanic current in a saline solution instantly develops the chemical process of electrolysis, which in turn induces electrochemical ablation of fibrosis. In this article, the interventional procedure is presented in detail, and both the strengths and limits of the technique are discussed. Results US-guided EPI eliminates the fibrotic accumulation that causes PHTrSNE, without the semimembranosus tendon or the sciatic nerve being directly involved during the procedure. The technique is however of limited use in cases of compression neuropathy. Conclusion US-guided EPI is a technique that is quick to perform, minimally invasive and does not force the patient to suspend their activities (work or sports) to make the treatment effective. This, coupled to the fact that the technique is generally well-tolerated by patients, supports use of US-guided EPI in the treatment of PHTrSNE. PMID:27900300
Dai, Jian; Katoh, Osamu; Kyo, Eisho; Tsuji, Takafumi; Watanabe, Satoshi; Ohya, Hidefumi
2013-10-01
Controlled antegrade and retrograde subintimal tracking (CART) or reverse CART techniques is the final step for percutaneous revascularization of coronary chronic total occlusion (CTO), but it still represents technical challenges and risk in interventional procedures. Our purpose was to utilize intravascular ultrasound (IVUS)-guided reverse CART approach for percutaneous revascularization of CTO in our heart center, focusing on its safety, efficacy, and latest technical developments. From November 2006 to November 2012, 49 patients with CTO failed to antegrade and/or retrograde percutaneous revascularization of CTO from true lumen to true lumen were enrolled in and underwent IVUS guided reverse CART approach. The mean J-CTO score of cases was 2.5. IVUS guidance was successfully implemented in 95.9%; IVUS identified that 61.7% of retrograde wires were located at intimal space, and 59.5% of antegrade wires were located at subintimal space. A Corsair channel dilator was used in 77.6% of cases. The success rates of technique and procedure were 95.9% and 93.9%, respectively; the technical minor complications were observed in 10.2% of cases, without significant clinic outcomes; 2.0% of cases occurred with a major adverse cardiac event of non-ST-elevation myocardial infarction; and no case occurred with target vessel revascularization or death. The mean length of stent implanted in a single CTO vessel was 51.3 mm. No patient appeared with radiation dermatitis and contrast-induced rise of creatinine. IVUS guided reverse CART approach is effective and safe for percutaneous revascularization of complex CTO, with a high success and a low complication rate. It is feasible to develop this approach for percutaneous revascularization of complex CTO. However, suitable case selection and lately device handling by experienced operators are the crucial points of success. © 2013, Wiley Periodicals, Inc.
Kahaleh, Michel; Artifon, Everson LA; Perez-Miranda, Manuel; Gaidhane, Monica; Rondon, Carlos; Itoi, Takao; Giovannini, Marc
2015-01-01
Endoscopic retrograde cholangiopancreatography (ERCP) is the preferred procedure for biliary and pancreatic drainage. While ERCP is successful in about 95% of cases, a small subset of cases are unsuccessful due to altered anatomy, peri-ampullary pathology, or malignant obstruction. Endoscopic ultrasound-guided drainage is a promising technique for biliary, pancreatic and recently gallbladder decompression, which provides multiple advantages over percutaneous or surgical biliary drainage. Multiple retrospective and some prospective studies have shown endoscopic ultrasound-guided drainage to be safe and effective. Based on the currently reported literature, regardless of the approach, the cumulative success rate is 84%-93% with an overall complication rate of 16%-35%. endoscopic ultrasound-guided drainage seems a viable therapeutic modality for failed conventional drainage when performed by highly skilled advanced endoscopists at tertiary centers with expertise in both echo-endoscopy and therapeutic endoscopy PMID:25624708
[Pancreatic tail pseudoaneurysm: percutaneous treatment by thrombin injection].
Pacheco Jiménez, M; Moreno Sánchez, T; Moreno Rodríguez, F; Guillén Rico, M
2014-01-01
Visceral artery pseudoaneurysms secondary to acute and/or chronic pancreatitis are a relatively common and potentially serious complication. Endovascular techniques are the most currently accepted techniques, given the higher morbidity-mortality of surgery. The thrombosis of the pseudoaneurysm using an ultrasound-guided percutaneous thrombin injection is emerging as a useful option in those cases in which endovascular embolisation is not possible. We present the case of a patient with a pseudoaneurysm of the transverse pancreatic artery secondary to chronic pancreatitis, and successfully treated by administering percutaneous thrombin. Copyright © 2011 SERAM. Published by Elsevier Espana. All rights reserved.
Endoscopic ultrasound-guided choledochoduodenostomy after a failed or impossible ERCP.
Mora Soler, Ana María; Álvarez Delgado, Alberto; Piñero Pérez, María Concepción; Velasco-Guardado, Antonio; Marcos Prieto, Héctor; Rodríguez Pérez, Antonio
2018-05-01
endoscopic ultrasound-guided biliary drainage (EUS-BD) is an alternative to percutaneous trans-hepatic biliary drainage (PTBD) in cases of failed endoscopic retrograde cholangiopancreatography (ERCP). this is a retrospective description of six cases of endoscopic ultrasound-guided biliary drainage via choledochoduodenostomy (EUCD), as well as the clinical characteristics, endoscopic procedure, complications and monitoring. all cases had malignant distal biliary obstruction. The procedure was concluded with good drainage in four out of six patients. Two late complications were recorded that were caused by stent migration and there were no deaths related with the procedure. The average monitoring period was six months. EUCD can be considered as a valid therapeutic choice in some selected cases and when performed by a team of expert endoscopists in cases of failed ERCP drainage or as an alternative to PTBD. However, the procedure has some associated complications.
Matsuyama, Masato; Ishii, Hiroshi; Kuraoka, Kensuke; Yukisawa, Seigo; Kasuga, Akiyoshi; Ozaka, Masato; Suzuki, Sho; Takano, Kouichi; Sugiyama, Yuko; Itoi, Takao
2013-01-01
AIM: To clarify the effectiveness and safety of endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) for the diagnosis of pancreatic cancer (PC). METHODS: Patients who were diagnosed with unresectable, locally advanced or metastatic PC between February 2006 and September 2011 were selected for this retrospective study. FNA biopsy for pancreatic tumors had been performed percutaneously under extracorporeal ultrasound guidance until October 2009; then, beginning in November 2009, EUS-FNA has been performed. We reviewed the complete medical records of all patients who met the selection criteria for the following data: sex, age, location and size of the targeted tumor, histological and/or cytological findings, details of puncture procedures, time from day of puncture until day of definitive diagnosis, and details of severe adverse events. RESULTS: Of the 121 patients who met the selection criteria, 46 had a percutaneous biopsy (Group A) and 75 had an EUS-FNA biopsy (Group B). Adequate cytological specimens were obtained in 42 Group A patients (91.3%) and all 75 Group B patients (P = 0.0192), and histological specimens were obtained in 41 Group A patients (89.1%) and 65 Group B patients (86.7%). Diagnosis of malignancy by cytology was positive in 33 Group A patients (78.6%) and 72 Group B patients (94.6%) (P = 0.0079). Malignancy by both cytology and pathology was found in 43 Group A (93.5%) and 73 Group B (97.3%) patients. The mean period from the puncture until the cytological diagnosis in Group B was 1.7 d, which was significantly shorter than that in Group A (4.1 d) (P < 0.0001). Severe adverse events were experienced in two Group A patients (4.3%) and in one Group B patient (1.3%). CONCLUSION: EUS-FNA, as well as percutaneous needle aspiration, is an effective modality to obtain cytopathological confirmation in patients with advanced PC. PMID:23613631
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chiba, Emiko, E-mail: chibaemi23@comet.ocn.ne.jp; Hamamoto, Kohei, E-mail: hkouhei917@gmail.com; Nagashima, Michio, E-mail: nagamic00@gmail.com
PurposeTo evaluate the efficacy and safety of ultrasound (US)-guided axillary brachial plexus block (ABPB) for analgesia during percutaneous transluminal angioplasty (PTA) for dialysis access.Subjects and MethodsTwenty-one patients who underwent PTA for stenotic dialysis access shunts and who had previous experience of PTA without sedation, analgesia, and anesthesia were included. The access type in all patients was native arteriovenous fistulae in the forearm. Two radiologists performed US-guided ABPB for the radial and musculocutaneous nerves before PTA. The patients’ pain scores were evaluated using a visual analog scale (VAS) after PTA, and these were compared with previous sessions without US-guided ABPB. Themore » patient’s motor/sensory paralysis after PTA was also examined.ResultsThe mean time required to achieve US-guided ABPB was 8 min. The success rate of this procedure was 100 %, and there were no significant complications. All 21 patients reported lower VAS with US-guided ABPB as compared to without the block (p < 0.01). All patients expressed the desire for an ABPB for future PTA sessions, if required. Transient motor paralysis occurred in 8 patients, but resolved in all after 60 min.ConclusionUS-guided ABPB is feasible and effective for analgesia in patients undergoing PTA for stenotic dialysis access sites.Level of EvidenceLevel 4 (case series).« less
Accuracy and safety of ultrasound-guided percutaneous needle core biopsy of renal masses
Wang, Xianding; Lv, Yuanhang; Xu, Zilin; Aniu, Muguo; Qiu, Yang; Wei, Bing; Li, Xiaohong; Wei, Qiang; Dong, Qiang; Lin, Tao
2018-01-01
Abstract Our aim is to determine the sufficiency, accuracy, and safety of ultrasound-guided percutaneous needle core biopsy of renal masses in Chinese patients. Patients who had undergone ultrasound-guided needle core renal mass biopsy from June 2012 to June 2016 at West China Hospital, China were retrospectively reviewed. The information obtained included demographics, mass-related parameters, biopsy indications, technique, complications, pathologic results, and follow-up. Concordance of surgical resection pathology and follow-up data were assessed. Renal mass biopsies were performed in 106 patients. Thirty-nine (36.8%) were asymptomatic. The male/female ratio was 60/46, with a median age of 49.5 years. Median mass size was 8.1 cm (range 1.8–20). Biopsy was performed through a 16-gauge needle, with median cores of 2 taken (range 1–5). Only one significant biopsy-related complication (hemorrhage requiring transfusion) was encountered. An adequate tissue sample was obtained in 97.2% (103/106) of biopsies. Eighty-seven biopsies (82.1%) showed malignant neoplasms, 16 (15.1%) yielded benignity, and 3 (2.8%) were nondiagnostic. After biopsy, 46 patients (43.4%) underwent surgery. Compared with the subsequent mass resection pathology, the biopsy diagnoses were identical in 43 cases. The accuracy rate of biopsy distinguishing malignant from benign lesions was 99.1%, and the rate for determining tumor histological type (excluding the nondiagnostic biopsies) was 95.1%. The sensitivity and specificity in detecting malignancy were 98.9% and 100%, respectively. In several situations, there is still a role for biopsy before intervention. Percutaneous needle core biopsy under ultrasonography guidance is highly accurate and safe, and can determine the proper management of undefinable masses. PMID:29595650
Milella, Marialessia; Alfa-Wali, Maryam; Leuratti, Luca; McCall, James; Bonanomi, Gianluca
2014-01-01
INTRODUCTION Gallstones are a common condition in bariatric patients after a laparoscopic Roux-en-Y gastric bypass (LRYGB). The management of ductal stones is challenging due to the altered gastrointestinal anatomy. Various techniques have been reported to manage bile duct stones. PRESENTATION OF CASE We present the successful percutaneous trans hepatic management of common bile duct stones after LRYGB. One year after a LRYGB for morbid obesity, a 59-year-old female presented with acute cholecystitis. One month after laparoscopic cholecystectomy a 1 cm calculus was found within the distal CBD and patient underwent a percutaneous trans hepatic cholangiography under local anesthetic. This involved a right sided anterior segmental duct puncture. With the sphincter dilated to 10 mm, a balloon catheter was used to push the stone into the duodenum leaving an internal- external drain. Patient recovered completely at follow up. DISCUSSION Patients with morbid obesity have a higher incidence of gallstones. After LRYGB, the altered anatomy does not allow the conventional endoscopic retrograde cholangiopancreatography (ERCP) for choledocholithiasis. Various techniques have been reported as means of managing bile duct stones in LRYGB patients. These include a double balloon enteroscope-assisted ERCP, laparoscopic transgastric ERCP, laparoscopic or open biliary surgery and interventional radiology. We report a non-surgical approach using percutaneous transhepatic technique under local anesthetic that resulted effective and could be applied more extensively. CONCLUSION Due to the increase of global obesity, bariatric centers need to strategically plan resources such as interventional radiology in order to manage post LRYGB choledocholithiasis safely, efficiently and in a cost effective manner. PMID:24705194
Milella, Marialessia; Alfa-Wali, Maryam; Leuratti, Luca; McCall, James; Bonanomi, Gianluca
2014-01-01
Gallstones are a common condition in bariatric patients after a laparoscopic Roux-en-Y gastric bypass (LRYGB). The management of ductal stones is challenging due to the altered gastrointestinal anatomy. Various techniques have been reported to manage bile duct stones. We present the successful percutaneous trans hepatic management of common bile duct stones after LRYGB. One year after a LRYGB for morbid obesity, a 59-year-old female presented with acute cholecystitis. One month after laparoscopic cholecystectomy a 1cm calculus was found within the distal CBD and patient underwent a percutaneous trans hepatic cholangiography under local anesthetic. This involved a right sided anterior segmental duct puncture. With the sphincter dilated to 10mm, a balloon catheter was used to push the stone into the duodenum leaving an internal- external drain. Patient recovered completely at follow up. Patients with morbid obesity have a higher incidence of gallstones. After LRYGB, the altered anatomy does not allow the conventional endoscopic retrograde cholangiopancreatography (ERCP) for choledocholithiasis. Various techniques have been reported as means of managing bile duct stones in LRYGB patients. These include a double balloon enteroscope-assisted ERCP, laparoscopic transgastric ERCP, laparoscopic or open biliary surgery and interventional radiology. We report a non-surgical approach using percutaneous transhepatic technique under local anesthetic that resulted effective and could be applied more extensively. Due to the increase of global obesity, bariatric centers need to strategically plan resources such as interventional radiology in order to manage post LRYGB choledocholithiasis safely, efficiently and in a cost effective manner. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.
[Contrast-enhanced ultrasound (CEUS) and image fusion for procedures of liver interventions].
Jung, E M; Clevert, D A
2018-06-01
Contrast-enhanced ultrasound (CEUS) is becoming increasingly important for the detection and characterization of malignant liver lesions and allows percutaneous treatment when surgery is not possible. Contrast-enhanced ultrasound image fusion with computed tomography (CT) and magnetic resonance imaging (MRI) opens up further options for the targeted investigation of a modified tumor treatment. Ultrasound image fusion offers the potential for real-time imaging and can be combined with other cross-sectional imaging techniques as well as CEUS. With the implementation of ultrasound contrast agents and image fusion, ultrasound has been improved in the detection and characterization of liver lesions in comparison to other cross-sectional imaging techniques. In addition, this method can also be used for intervention procedures. The success rate of fusion-guided biopsies or CEUS-guided tumor ablation lies between 80 and 100% in the literature. Ultrasound-guided image fusion using CT or MRI data, in combination with CEUS, can facilitate diagnosis and therapy follow-up after liver interventions. In addition to the primary applications of image fusion in the diagnosis and treatment of liver lesions, further useful indications can be integrated into daily work. These include, for example, intraoperative and vascular applications as well applications in other organ systems.
Percutaneous Image-Guided Aspiration and Sclerosis of Adventitial Cystic Disease of the Femoral Vein
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johnson, Jason M.; Kiankhooy, Armin; Bertges, Daniel J.
2009-07-15
Adventitial cystic disease (ACD), also known as cystic mucoid or myxomatous degeneration, is a rare vascular disease mainly seen in arteries. Seventeen cases have been reported in the world literature. We report the first known case of ACD successfully treated with percutaneous image-guided ethanol sclerosis. Computed tomography showed a cystic mass adherent to the wall of the common femoral vein. An ultrasound examination revealed a deep venous thrombosis of the leg, secondary to extrinsic compression of the common femoral vein. Three years prior to our procedure, the cyst was aspirated, which partially relieved the patient's symptoms. Over the following 3more » years the patient's symptoms worsened and a 10-cm discrepancy in thigh size developed, in addition to the deep venous thrombosis associated with lower-extremity edema. Using ultrasound guidance and fluoroscopic control, the cyst was drained and then sclerosed with absolute ethanol. The patient's symptoms and leg swelling resolved completely within several weeks. Follow-up physical examination and duplex ultrasound 6 months following sclerosis demonstrated resolution of the symptoms and elimination of the extrinsic compression effect of the ACD on the common femoral vein.« less
Liu, Zhiyi; Zhang, Luyao; Liu, Yanling; Gu, Yang; Sun, Tieliang
2017-11-01
We aimed to evaluate the efficiency and safety of one-step procedure combined endoscopic retrograde cholangiopancreatography (ERCP) and laparoscopic cholecystectomy (LC) for treatment of patients with cholecysto-choledocholithiasis. A prospective randomized study was performed on 63 consecutive cholecysto-choledocholithiasis patients during 2008 and 2011. The efficiency and safety of one-step procedure was assessed by comparing the two-step LC with ERCP + endoscopic sphincterotomy (EST). Outcomes including intraoperative features, postoperative features (length of stay and postoperative complications) were evaluated. One- or two-step procedure of LC with ERCP + EST was successfully performed in all patients, and common bile duct stones were completely removed. Statistical analyses showed that length of stay and pulmonary infection rate were significantly lower in the test group compared with that in the control group (P < 0.05), whereas no statistical difference in other outcomes was found between the two groups (all P > 0.05). The one-step procedure of LC with ERCP + EST is superior to the two-step procedure for treatment of patients with cholecysto-choledocholithiasis regarding to the reduced hospital stay and inhibited occurrence of pulmonary infections. Compared with two-step procedure, one-step procedure of LC with ERCP + EST may be a superior option for cholecysto-choledocholithiasis patients treatment regarding to hospital stay and pulmonary infections.
2016-01-01
Purposes. To present our series of 38 prone percutaneous nephrolithotomy procedures performed with renal access and tract dilation purely under ultrasound guidance and describe the benefits and challenges accompanying this approach. Methods. Thirty-eight consecutive patients presenting for percutaneous nephrolithotomy for renal stone removal were included in this prospective cohort study. Ultrasonographic imaging in the prone position was used to obtain percutaneous renal access and guide tract dilation. Fluoroscopic screening was used only for nephrostomy tube placement. Preoperative, intraoperative, and postoperative procedural and patient data were collected for analysis. Results. Mean age of patients was 52.7 ± 17.2 years. Forty-five percent of patients were male with mean BMI of 26.1 ± 7.3 and mean stone size of 27.2 ± 17.6 millimeters. Renal puncture was performed successfully with ultrasonographic guidance in all cases with mean puncture time of 135.4 ± 132.5 seconds. Mean dilation time was 11.5 ± 3.8 min and mean stone fragmentation time was 37.5 ± 29.0 min. Mean total operative time was 129.3 ± 41.1. No patients experienced any significant immediate postoperative complication. All patients were rendered stone-free and no additional secondary procedures were required. Conclusions. Ultrasound guidance for renal access and tract dilation in prone percutaneous nephrolithotomy is a feasible and effective technique. It can be performed safely with significantly reduced fluoroscopic radiation exposure to the patient, surgeon, and intraoperative personnel. PMID:27042176
Outcomes of Ultrasound-Guided Thrombin Injection of Nongroin Arterial Pseudoaneurysms.
Valesano, Johnathan C; Schmitz, John J; Kurup, A Nicholas; Schmit, Grant D; Moynagh, Michael R; Atwell, Thomas D; Lewis, Bradley D; Lee, Robert A; Callstrom, Matthew R
2017-08-01
To evaluate success and complication rates of percutaneous ultrasound-guided thrombin injection of nongroin pseudoaneurysms (PSAs). Retrospective review of a prospectively maintained institutional database yielded 39 cases of arterial PSAs occurring at nongroin sites that were treated with percutaneous ultrasound-guided thrombin injection between 2000 and 2016 (average patient age 69.2 y ± 14.0). Of PSAs, 74.4% (29/39) arose in the upper extremities, and 92.3% (36/39) were iatrogenic. The brachial artery was the most commonly affected vessel (51.3% [20/39]), and arterial access was the most common cause (56.4% [22/39]). Average overall PSA size was 2.4 cm (range, 0.5-7.2 cm); average amount of thrombin injected was 320 IU (range, 50-2,000 IU). Technical success was defined as absence of flow within the PSA immediately after thrombin injection. Treatment success was defined as sustained thrombosis on follow-up imaging obtained at 1-3 days after treatment. Technical and treatment success rates of thrombin injections were 100% (39/39) and 84.8% (28/33), respectively. Longer term follow-up imaging (average 71 d; range, 12-201 d) was available for 7 of the treatment successes with 100% (7/7) showing sustained thrombosis. Comparing treatment successes and failures, there was no significant difference in average PSA size (2.3 cm vs 2.0 cm, P = .51) or average amount of thrombin injected (360 IU vs 180 IU, P = .14). There were no complications. Ultrasound-guided thrombin injection is a safe, efficacious treatment option for PSAs arising in nongroin locations. Copyright © 2017 SIR. Published by Elsevier Inc. All rights reserved.
Analysis of different ways of drainage for obstructive jaundice caused by hilar cholangiocarcinoma.
Xu, Chuan; Lv, Peng-Hua; Huang, Xin-En; Wang, Shu-Xiang; Sun, Ling; Wang, Fu-An
2014-01-01
To evaluate the prognosis of different ways of drainage for patients with obstructive jaundice caused by hilar cholangiocarcinoma. During the period of January 2006- March 2012, percutaneous transhepatic catheter drainage (PTCD)/ percutaneous transhepatic biliary stenting (PTBS) were performed for 89 patients. According to percutaneous transhepatic cholangiography (PTC), external drainage was selected if the region of obstruction could not be passed by guide wire or a metallic stent was inserted if it could. External drainage was the first choice if infection was diagnosed before the procedure, and a metallic stent was inserted in one week after the infection was under control. Selection by new infections, the degree of bilirubin decrease, the change of ALT, the time of recurrence of obstruction, and the survival time of patients as the parameters was conducted to evaluate the methods of different interventional treatments regarding prognosis of patients with hilar obstruction caused by hilar cholangiocarcinoma. PTCD was conducted in 6 patients and PTBS in 7 (p<0.05). Reduction of bilirubin levels and ALT levels was obvious after the procedures (p<0.05). The average survival time with PTCD was 161 days and with PTBS was 243 days (p<0.05). With both drainage procedures for obstructive jaundice caused by hilar cholangiocarcinoma improvement in liver function was obvious. PTBS was found to be better than PTCD for prolonging the patient survival.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boyvat, Fatih, E-mail: boyvatf@yahoo.com; Aytekin, Cueneyt; Harman, Ali
Budd-Chiari syndrome (BCS) is an uncommon disorder that can be life-threatening, depending on the degree of hepatic venous outflow obstruction. Transjugular intrahepatic portosystemic shunt (TIPS) provides decompression of the congested liver but the hepatic vein obstruction makes the procedure more difficult. We describe a modified method that involved a single percutaneous puncture of the portal vein and inferior vena cava simultaneously for TIPS creation in a patient with BCS.
Jacobson, Jon A; Yablon, Corrie M; Henning, P Troy; Kazmers, Irene S; Urquhart, Andrew; Hallstrom, Brian; Bedi, Asheesh; Parameswaran, Aishwarya
2016-11-01
The purpose of this study was to compare ultrasound-guided percutaneous tendon fenestration to platelet-rich plasma (PRP) injection for treatment of greater trochanteric pain syndrome. After Institutional Review Board approval was obtained, patients with symptoms of greater trochanteric pain syndrome and ultrasound findings of gluteal tendinosis or a partial tear (<50% depth) were blinded and treated with ultrasound-guided fenestration or autologous PRP injection of the abnormal tendon. Pain scores were recorded at baseline, week 1, and week 2 after treatment. Retrospective clinic record review assessed patient symptoms. The study group consisted of 30 patients (24 female), of whom 50% were treated with fenestration and 50% were treated with PRP. The gluteus medius was treated in 73% and 67% in the fenestration and PRP groups, respectively. Tendinosis was present in all patients. In the fenestration group, mean pain scores were 32.4 at baseline, 16.8 at time point 1, and 15.2 at time point 2. In the PRP group, mean pain scores were 31.4 at baseline, 25.5 at time point 1, and 19.4 at time point 2. Retrospective follow-up showed significant pain score improvement from baseline to time points 1 and 2 (P< .0001) but no difference between treatment groups (P= .1623). There was 71% and 79% improvement at 92 days (mean) in the fenestration and PRP groups, respectively, with no significant difference between the treatments (P >.99). Our study shows that both ultrasound-guided tendon fenestration and PRP injection are effective for treatment of gluteal tendinosis, showing symptom improvement in both treatment groups. © 2016 by the American Institute of Ultrasound in Medicine.
Ultrasound-guided percutaneous tracheostomy in critically ill obese patients
2012-01-01
Introduction The purpose of this study was to evaluate the feasibility of ultrasound (US)-guided percutaneous tracheostomy (PCT) and the incidence of complications in critically ill, obese patients. Methods Fifty consecutive patients were included in a prospective study in two surgical and critical care medicine departments. Obesity was defined as a body mass index (BMI) of at least 30 kg/m2. The feasibility of PCT and the incidence of complications were compared in obese patients (n = 26) and non-obese patients (n = 24). Results are expressed as the median (25th-75th percentile) or number (percentage). Results The median BMIs were 34 kg/m2 (32-38) in the obese patient group and 25 kg/m2 (24-28) in the non-obese group (p < 0.001). The median times for tracheostomy were 10 min (8-14) in non-obese patients and 9 min (5-10) in obese-patients (p = 0.1). The overall complication rate was similar in obese and non-obese patient groups (35% vs. 33%, p = 0.92). Most complications were minor (hypotension, desaturation, tracheal cuff puncture and minor bleeding), with no differences between obese and non-obese groups. Bronchoscopic inspection revealed two cases of granuloma (8%) in obese patients. One non-obese patient developed a peristomal skin infection, which was treated with intravenous antibiotics. Ultrasound-guided PCT was possible in all enrolled patients and there were no surgical conversions or deaths. Conclusions This study demonstrated that US-guided PCT is feasible in obese patients with a low complication rate. Obesity may not constitute a contra-indication for US-guided PCT. A US examination provides information on cervical anatomy and hence modifies and guides choice of the PCT puncture site. Trial registration ClinicalTrials.gov: NCT01502657. PMID:22390815
Ultrasound-guided percutaneous tracheostomy in critically ill obese patients.
Guinot, Pierre-Grégoire; Zogheib, Elie; Petiot, Sandra; Marienne, Jean-Pierre; Guerin, Anne-Marie; Monet, Pauline; Zaatar, Rody; Dupont, Hervé
2012-12-12
The purpose of this study was to evaluate the feasibility of ultrasound (US)-guided percutaneous tracheostomy (PCT) and the incidence of complications in critically ill, obese patients. Fifty consecutive patients were included in a prospective study in two surgical and critical care medicine departments. Obesity was defined as a body mass index (BMI) of at least 30 kg/m². The feasibility of PCT and the incidence of complications were compared in obese patients (n = 26) and non-obese patients (n = 24). Results are expressed as the median (25th-75th percentile) or number (percentage). The median BMIs were 34 kg/m² (32-38) in the obese patient group and 25 kg/m² (24-28) in the non-obese group (p < 0.001). The median times for tracheostomy were 10 min (8-14) in non-obese patients and 9 min (5-10) in obese-patients (p = 0.1). The overall complication rate was similar in obese and non-obese patient groups (35% vs. 33%, p = 0.92). Most complications were minor (hypotension, desaturation, tracheal cuff puncture and minor bleeding), with no differences between obese and non-obese groups. Bronchoscopic inspection revealed two cases of granuloma (8%) in obese patients. One non-obese patient developed a peristomal skin infection, which was treated with intravenous antibiotics. Ultrasound-guided PCT was possible in all enrolled patients and there were no surgical conversions or deaths. This study demonstrated that US-guided PCT is feasible in obese patients with a low complication rate. Obesity may not constitute a contra-indication for US-guided PCT. A US examination provides information on cervical anatomy and hence modifies and guides choice of the PCT puncture site. ClinicalTrials.gov: NCT01502657.
Percutaneous transhepatic bile drainage.
Mori, K; Misumi, A; Sugiyama, M; Okabe, M; Matsuoka, T
1977-01-01
Percutaneous transhepatic bile drainage was performed in 13 patients with obstructive jaundice, using a combination of the PTC technique and a Seldinger angiography catheter. In 11 cases, the outflow of bile through the catheter was satisfactory and complications were few. Since the risk of the procedure is low and it can be done without laparotomy, it is an ideal technic for biliary decompression before attempting to do a resection. Also, repeated cholangiography through a catheter which is left in place is helpful as a diagnostic aid before and after surgery. Images Fig. 3. Fig. 4. Fig. 5. Fig. 6. PMID:831630
Gesualdo, Loreto; Cormio, Luigi; Stallone, Giovanni; Infante, Barbara; Di Palma, Anna Maria; Delli Carri, Paolo; Cignarelli, Mauro; Lamacchia, Olga; Iannaccone, Salvatore; Di Paolo, Salvatore; Morrone, Luigi; Aucella, Filippo; Carrieri, Giuseppe
2008-03-01
Percutaneous ultrasound (US)-guided renal biopsy is the gold standard in the evaluation of renal diseases, but some patients, such as the obese, may not be eligible for this procedure. Aim of this study was to determine the feasibility, efficacy and safety of US-guided percutaneous renal biopsy in supine antero-lateral position (SALP) in high-risk patients (BMI > 30 and/or respiratory difficulty), as well as to compare the overall outcome of SALP with that of traditional prone position (PP) in low-risk patients (BMI < or = 30/no respiratory difficulty). One hundred and ten consecutive patients scheduled for native kidney biopsy were recruited. Ninety low-risk patients were randomized following a permuted block randomization list to receive either US-guided renal biopsy in PP (Group 1) or SALP (Group 2), whereas 20 high-risk patients received US-guided renal biopsy in SALP (Group 3) and were our observational cohort study. Comfort compliance and breathing difficulty in each group were evaluated by the Visual Analogue Scale (VAS). Bleeding complications were evaluated through US renal scanning. Mean operating time was 7 min. Comfort compliance and breathing difficulty were significantly better for SALP in both low- and high-risk patients; there were no significant differences in pain after biopsy among the three groups. Bleeding complications were slightly higher in Group 1. Diagnostic yield was similar in all groups. SALP is reliable, minimally invasive, easy, highly successful, timesaving and almost free from severe side-effects. A better VAS score for breathing difficulty and comfort compliance characterizes this procedure, making it particularly suitable for obese patients.
Bazzocchi, Alberto; Pelotti, Patrizia; Serraino, Salvatore; Battaglia, Milva; Bettelli, Graziano; Fusaro, Isabella; Guglielmi, Giuseppe; Rotini, Roberto; Albisinni, Ugo
2016-01-01
Rotator cuff calcific tendinitis (RCCT) is a common cause of shoulder pain in adults and typically presents as activity-related shoulder pain. Between non-surgical and surgical treatment options, today a few minimal invasive techniques are available to remove the calcific deposit, and they represent a cornerstone in the management of this painful clinical condition. The aim of the work was a retrospective evaluation of double-needle ultrasound-guided percutaneous fragmentation and lavage (DNL), focused on understanding the factors which are of major importance in determining a quick and good response at 1 month. A series of 147 patients affected by RCCT and suitable for DNL were evaluated. A systematic review of anamnestic, clinical and imaging data was performed in 144 shoulders treated in a single-centre setting. Clinical reports and imaging examinations were revisited. The inclusion criteria were submission to DNL, therefore fitness for the percutaneous procedure, and following 1-month follow-up. There was no exclusion owing to risk of bias. The treatment was defined as successful for constant shoulder modified score (CSS) improvement of >50% at 1 month. In 70% of shoulders, the treatment resulted in a quick and significant reduction of symptoms (successful). On the whole, CSS increase at 1 month was estimated at 91.5 ± 69.1%. CSS variations were significantly related to age of patients (better results between 30 and 40 years old), calcification size (more relevant improvement for middle-sized calcifications, 12-17 mm), sonographic and radiographic features of calcific deposits (softer calcifications) and thickening of subacromial/subdeltoid bursa walls. In the final model of stepwise regression for CSS variation, ultrasound score pre-treatment and post-treatment, the distance between bursa and calcification before treatment and the size of post-treatment calcification area were shown to be independently correlated to success. Numeric rating scale score for pain showed similar results. Pain at admission was also related to age, calcification size, ultrasound and Gärtner score, power Doppler positivity, bursal wall thickening and biceps tenosynovitis. The success of the procedure with quick improvement in function and symptoms is warranted in soft and middle-sized calcifications, in young adults. Ultrasound-guided percutaneous procedures for RCCT must be safe, effective and with prompt pain relief and function restoration. This study shows which clinical picture is more favourable to this purpose and actual prognostic factors for DNL (soft and middle-sized calcifications, in young adults, are more favourable).
Pelotti, Patrizia; Serraino, Salvatore; Battaglia, Milva; Bettelli, Graziano; Fusaro, Isabella; Guglielmi, Giuseppe; Rotini, Roberto; Albisinni, Ugo
2016-01-01
Objective: Rotator cuff calcific tendinitis (RCCT) is a common cause of shoulder pain in adults and typically presents as activity-related shoulder pain. Between non-surgical and surgical treatment options, today a few minimal invasive techniques are available to remove the calcific deposit, and they represent a cornerstone in the management of this painful clinical condition. The aim of the work was a retrospective evaluation of double-needle ultrasound-guided percutaneous fragmentation and lavage (DNL), focused on understanding the factors which are of major importance in determining a quick and good response at 1 month. Methods: A series of 147 patients affected by RCCT and suitable for DNL were evaluated. A systematic review of anamnestic, clinical and imaging data was performed in 144 shoulders treated in a single-centre setting. Clinical reports and imaging examinations were revisited. The inclusion criteria were submission to DNL, therefore fitness for the percutaneous procedure, and following 1-month follow-up. There was no exclusion owing to risk of bias. The treatment was defined as successful for constant shoulder modified score (CSS) improvement of >50% at 1 month. Results: In 70% of shoulders, the treatment resulted in a quick and significant reduction of symptoms (successful). On the whole, CSS increase at 1 month was estimated at 91.5 ± 69.1%. CSS variations were significantly related to age of patients (better results between 30 and 40 years old), calcification size (more relevant improvement for middle-sized calcifications, 12–17 mm), sonographic and radiographic features of calcific deposits (softer calcifications) and thickening of subacromial/subdeltoid bursa walls. In the final model of stepwise regression for CSS variation, ultrasound score pre-treatment and post-treatment, the distance between bursa and calcification before treatment and the size of post-treatment calcification area were shown to be independently correlated to success. Numeric rating scale score for pain showed similar results. Pain at admission was also related to age, calcification size, ultrasound and Gärtner score, power Doppler positivity, bursal wall thickening and biceps tenosynovitis. Conclusion: The success of the procedure with quick improvement in function and symptoms is warranted in soft and middle-sized calcifications, in young adults. Advances in knowledge: Ultrasound-guided percutaneous procedures for RCCT must be safe, effective and with prompt pain relief and function restoration. This study shows which clinical picture is more favourable to this purpose and actual prognostic factors for DNL (soft and middle-sized calcifications, in young adults, are more favourable). PMID:26607641
Breda, Alberto; Territo, Angelo; Scoffone, Cesare; Seitz, Christian; Knoll, Thomas; Herrmann, Thomas; Brehmer, Mariannhe; Osther, Palle J S; Liatsikos, Evangelos
2017-11-12
Percutaneous nephrolithotomy (PNL) is the treatment of choice for larger and complex renal calculi. First step in performing PNL is to obtain access to the renal cavity using either fluoroscopy or ultrasound (US) guidance or a combination of both. Which guiding method to choose is controversial? A systematic review of the literature was performed comparing image guidance modalities for obtaining access in PNL. Evidence acquisition and synthesis: A PubMed, Scopus and Cochrane search for peer-reviewed studies was performed using the keywords "ultrasound" AND "fluoroscopy" AND "Percutaneous nephrolithotomy". Eligible articles were reviewed according to PRISMA criteria. Two hundred and forty records were identified using the keywords. Of these twelve studies were considered relevant. US guidance seems to be associated with a slightly lower complication rate, which may be related to fewer puncture attempts needed for obtaining access and to better peri-renal organ visualization. On the other hand, US-guidance alone needs the adjunct of fluoroscopy in a significant number of cases for achieving access. Stone free rate (SFR) was comparable between groups. Using US for renal access unequivocally reduces radiation exposure. Current evidence indicates that both fluoroscopy and US guidance may be successfully used for obtaining percutaneous renal access. Combining the image-guiding modalities - US and fluoroscopy - seems to increase outcome in PNL both with regard to success in achieving access and reducing complications. Furthermore, including US in the access strategy of PNL reduces radiation exposure to surgeon and staff as well as patients.
Plantar fascia: imaging diagnosis and guided treatment.
McNally, Eugene G; Shetty, Shilpa
2010-09-01
Plantar fasciopathy is a common cause of heel pain. This article covers the imaging anatomy of the hindfoot, the imaging findings on ultrasound and magnetic resonance imaging (MRI) of plantar fasciopathy, plantar fibromas, trauma, Achilles tendonopathy, neural compression, stress fractures of the os calcis and other heel pad lesions. Thickening of the plantar fascia insertion more than 5 mm either on ultrasound or MRI is suggestive of plantar fasciopathy. Ultrasound is superior to MRI for diagnosis of plantar fibroma as small low signal lesions on MRI are similar to the normal plantar fascia signal. Ultrasound demonstrates low echogenicity compared with the echogenic plantar fascia. Penetrating injuries can appear bizarre due to associated foreign body impaction and infection. Achilles tendonopathy can cause heel pain and should be considered as a possible diagnosis. Treatment options include physical therapy, ECSWT, corticosteroid injection, and dry needling. Percutaneous US guided treatment methods will be described. Thieme Medical Publishers.
Narouze, Samer N; Zakari, Adel; Vydyanathan, Amaresh
2009-01-01
Femoral nerve injury is a rare complication of cardiac catheterization and is usually caused by direct trauma during femoral artery access, compression from a hematoma, or prolonged digital pressure for post-procedural hemostasis. Peripheral nerve stimulation has been used to treat different pain syndromes in the upper and lower extremities with variable success and it typically requires direct vision with open surgical approach. Since the femoral nerve can be readily seen with ultrasonography, an ultrasound-guided lead placement seemed practical. A 61-year-old morbidly obese male who sustained femoral nerve injury during cardiac catheterization continued to complain of intractable femoral neuropathy 18 months afterwords. He failed multiple treatment modalities and continued to complain of severe neuropathic pains that markedly interfere with his daily activities. Two percutaneous leads were placed under real-time ultrasonography and the placement was confirmed with fluoroscopy. One lead was placed along the longitudinal axis of the nerve and the patient had good coverage over the anterior thigh but not below the knee. So another lead was placed horizontally across the femoral nerve in order to stimulate all the branches and the patient reported good coverage along the saphenous nerve distribution down to the foot. The patient continues to be pain free 20 months after the implant. Here we described a novel non-invasive percutaneous approach for femoral nerve stimulation with ultrasound guidance which allowed precise placement of the stimulating lead very close to the femoral nerve without the need for surgical exploration.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Federle, M.P.; Cello J.P.; Laing, F.C.
1982-04-01
Five cases of recurrent pyogenic cholangitis (RPC) were studied by ultrasonography, computed tomography (CT), and cholangiography. All patients were recent immigrants from the Orient or Indonesia and had had recurrent attacks of cholangitis for many years. The bile was infected by E. coli and the biliary ducts were dilated; in addition, extrahepatic bile-pigment calculi we represent in all 5 and intrahepatic calculi in 4. Abdominal ultrasound usually failed to demonstrate duct calculi and extrahepatic dilatation due to the soft, mud-like consistency of the stones. CT was successful in showing the calculi and the full extent of dilatation. The authors concludemore » that preoperative diagnosis of RPC is best achieved by awareness of the characteristic clinical presentation and the findings on abdominal CT. Preoperative cholangiography provides excellent detail, but poses the danger of biliary sepsis requiring antibiotics.« less
Vyas, Sameer; Ahuja, Chirag Kamal; Yadav, Thakur Deen; Khandelwal, Niranjan
2012-09-01
Hepatic artery pseudoaneurysm (HAP) is an uncommon but serious complication of blunt trauma abdomen which can be managed by non-surgical interventional methods. We describe the case of a young boy with blunt trauma abdomen having a large hepatic laceration associated with two pseudoaneurysms of the hepatic artery branches. Both these HAPs were successfully managed by percutaneous injection of cyanoacrylate glue under sonographic guidance. A major surgery was thus averted. A brief review of the etiology, diagnosis and management of HAP including the present case is discussed.
Del Castillo-González, Federico; Ramos-Alvarez, Juan J; Rodríguez-Fabián, Guillermo; González-Pérez, José; Jiménez-Herranz, Elena; Varela, Enrique
2016-04-01
Extracorporeal shockwave treatment (ESWT) and ultrasound-guided percutaneous lavage (UGPL) are two effective ways of treating rotator cuff calcific tendinopathy (RCCT). The aim of the present study was to compare the effectiveness of these techniques in the treatment of RCCT. Prospective, randomized, controlled trial. Patients treated in our sports medicine and rehabilitation center (Centro Médico Deyre, Madrid. Spain) between January 2007 and December 2013. This randomized study compares the results achieved with these techniques over one year following their use to treat the above condition. Eighty patients received ESWT and 121 received UGPL. A visual analogue scale was used to measure pain, and ultrasound to determine the extent of calcification, at 3, 6, and 12 months after treatment. Pain and the amount of calcification were significantly reduced by both techniques at 3, 6 and 12 months (P<0.001 for each), but significantly more so by UGPL (P<0.001). Both techniques are valid for the treatment of RCCT, although UGPL is associated with a greater reduction of calcification and greater reduction in pain. The results obtained applying UGPL, the low cost and the lack of complications should therefore make the treatment of choice in centers that are appropriately equipped and staffed.
MR guided FUS therapy with a Robotic Assistance System
NASA Astrophysics Data System (ADS)
Jenne, Jürgen W.; Krafft, Axel J.; Maier, Florian; Rauschenberg, Jaane; Semmler, Wolfhard; Huber, Peter E.; Bock, Michael
2009-04-01
Magnetic Resonance imaging guided Focus Ultrasound Surgery (MRgFUS) is a highly precise method to ablate tissue non-invasively. To date, there is only one commercial MRgFUS system available and only a few are in a prototype stage. The objective of this ongoing project is to establish an MRgFUS therapy unit as add-on for a commercially available robotic assistance system originally designed for percutaneous needle interventions in whole-body MR scanners.
Hay, Ian D; Lee, Robert A; Davidge-Pitts, Caroline; Reading, Carl C; Charboneau, J William
2013-12-01
Ultrasound-guided percutaneous ethanol ablation (UPEA) of neck nodal metastases (NNM) has rarely been reported in papillary thyroid carcinoma (PTC) patients with advanced localized disease. We ablated 25 PTC patients with stage III or IVA disease (mean age 58 years) who had "recurrent" NNM after surgery and 131I therapy. Diagnosis of 37 selected NNM was proven by ultrasound-guided biopsy. UPEA was usually performed in 2 outpatient sessions. After UPEA, 35 of 37 NNM (95%) decreased in size. None had significant Doppler flow. Seventeen (46%) disappeared on rescanning. Serum thyroglobulin fell in 19 of 22 (86%) without thyroglobulin autoantibodies. None of the UPEA-treated NNM, followed on average for 5.4 years, required further intervention. Six patients (24%) subsequently developed 18 "new" recurrences. Of the 18, 15 (83%) were managed successfully by UPEA rather than operation. None of the 25 patients developed permanent hoarseness or have died from PTC. At our institution, where patients undergoing nodal dissections are charged $35-45,000, each outpatient UPEA procedure saves health providers approximately $38,400. Our 25 ablated patients, by avoiding 40 further neck reexplorations, on average, saved $61,440 in charges. UPEA for NNM in advanced localized PTC has proved safe and effective. It is also considerably less expensive than the conventional operative alternative of nodal dissection. Copyright © 2013 Mosby, Inc. All rights reserved.
Sainani, Nisha I; Arellano, Ronald S; Shyn, Paul B; Gervais, Debra A; Mueller, Peter R; Silverman, Stuart G
2013-08-01
Image-guided percutaneous biopsy of abdominal masses is among the most commonly performed procedures in interventional radiology. While most abdominal masses are readily amenable to percutaneous biopsy, some may be technically challenging for a number of reasons. Low lesion conspicuity, small size, overlying or intervening structures, motion, such as that due to respiration, are some of the factors that can influence the ability and ultimately the success of an abdominal biopsy. Various techniques or technologies, such as choice of imaging modality, use of intravenous contrast and anatomic landmarks, patient positioning, organ displacement or trans-organ approach, angling CT gantry, triangulation method, real-time guidance with CT fluoroscopy or ultrasound, sedation or breath-hold, pre-procedural image fusion, electromagnetic tracking, and others, when used singularly or in combination, can overcome these challenges to facilitate needle placement in abdominal masses that otherwise would be considered not amenable to percutaneous biopsy. Familiarity and awareness of these techniques allows the interventional radiologist to expand the use of percutaneous biopsy in clinical practice, and help choose the most appropriate technique for a particular patient.
Xu, Chuan; Huang, Xin-En; Wang, Shu-Xiang; Lv, Peng-Hua; Sun, Ling; Wang, Fu-An
2015-01-01
Percutaneous transhepatic biliary drainage (PTBD) is a form of palliative care for patients with malignant obstructive jaundice. We here compared the infection incidence between internal-external and external drainage for patients with malignant obstructive jaundice. Patients with malignant obstructive jaundice without infection before surgery receiving internal-external or external drainage from January 2008 to July 2014 were recruited. According to percutaneous transhepatic cholangiography (PTC), if the guide wire could pass through the occlusion and enter the duodenum, we recommended internal-external drainage, and external drainage biliary drainage was set up if the occlusion was not crossed. All patients with infection after procedure received a cultivation of blood and a bile bacteriological test. Among 110 patients with malignant obstructive jaundice, 22 (52.4%) were diagnosed with infection after the procedure in the internal-external drainage group, whereas 19 (27.9%) patients were so affected in the external drainage group, the difference being significant (p<0.05). In 8 patients (36.3%) in the internal-external group infection was controlled, as compared to 12 (63.1%) in the external group (p<0.05). The mortality rate for patients with infection not controlled in internal-external group in one month was 42.8%, while this rate in external group was 28.6% (p<0.05). External drainage is a good choice, which could significantly reduce the chance of biliary infection caused by bacteria, and decrease the mortality rate at one month and improve the long-term prognosis.
Ultrasound guided percutaneous cholecystostomy in high-risk patients for surgical intervention
Bakkaloglu, Huseyin; Yanar, Hakan; Guloglu, Recep; Taviloglu, Korhan; Tunca, Fatih; Aksoy, Murat; Ertekin, Cemalettin; Poyanli, Arzu
2006-01-01
AIM: To assess the efficacy and safety of ultrasound guided percutaneous cholecystostomy (PC) in the treatment of acute cholecystitis in a well-defined high risk patients under general anesthesia. METHODS: The data of 27 consecutive patients who underwent percutaneous transhepatic cholecystostomy for the management of acute cholecystitis from January 1999 to June 2003 was retrospectively evaluated. All of the patients had both clinical and sonographic signs of acute cholecystitis and had comorbid diseases. RESULTS: Ultrasound revealed gallbladder stones in 25 patients and acalculous cholecystitis in two patients. Cholecystostomy catheters were removed 14-32 d (mean 23 d) after the procedure in cases where complete regression of all symptoms was achieved. There were statistically significant reductions in leukocytosis, (13.7 × 103 ± 1.3 × 103 μg/L vs 13 × 103 ± 1 × 103 μg/L, P < 0.05 for 24 h after PC; 13.7 × 103 ± 1.3 × 103 μg/L vs 8.3 × 103 ± 1.2 × 103 μg/L, P < 0.0001 for 72 h after PC), C -reactive protein (51.2 ± 18.5 mg/L vs 27.3 ± 10.4 mg/L, P < 0.05 for 24 h after PC; 51.2 ± 18.5 mg/L vs 5.4 ± 1.5 mg/L, P < 0.0001 for 72 h after PC), and fever (38 ± 0.35°C vs 37.3 ± 0.32°C, P < 0.05 for 24 h after PC; 38 ± 0.35°C vs 36.9 ± 0.15°C, P < 0.0001 for 72 h after PC). Sphincterotomy and stone extraction was performed successfully with endoscopic retrograde cholangio-pancreatography (ERCP) in three patients. After cholecystostomy, 5 (18%) patients underwent delayed cholecystectomy without any complications. Three out of 22 patients were admitted with recurrent acute cholecystitis during the follow-up and recovered with medical treatment. Catheter dislodgement occurred in three patients spontaneously, and two of them were managed by reinsertion of the catheter. CONCLUSION: As an alternative to surgery, percutan-eous cholecystostomy seems to be a safe method in critically ill patients with acute cholecystitis and can be performed with low mortality and morbidity. Delayed cholecystectomy and ERCP, if needed, can be performed after the acute period has been resolved by percutaneous cholecystostomy. PMID:17131483
Feier, Flávia H; Chapchap, Paulo; Pugliese, Renata; da Fonseca, Eduardo A; Carnevale, Francisco C; Moreira, Airton M; Zurstrassen, Charles; Santos, Aline C; Miura, Irene K; Baggio, Vera; Porta, Adriana; Guimarães, Teresa; Cândido, Helry; Benavides, Marcel; Godoy, Andre; Leite, Katia M R; Porta, Gilda; Kondo, Mario; Seda-Neto, João
2014-08-01
The incidence of biliary complications (BCs) after living donor liver transplantation (LDLT) can reach 40%. Published data on the pediatric population are limited, and treatment protocols vary. Our aim was to describe the clinical scenario for BCs and treatment approaches after LDLT. Between October 1995 and December 2012, 489 pediatric LDLT procedures were performed. BCs developed in 71 patients (14.5%). Biliary strictures (BSs) developed in 45 (9.2%) patients, and bile leaks (BLs) developed in 33 patients (6.7%). The BL diagnosis was clinical in all cases, and 69.7% of the patients underwent surgery. Nearly half of the BS cases had clinical features or suggestive ultrasound findings. Liver biopsy findings suggested BSs in 51.7%. Percutaneous transhepatic cholangiography was performed in 95.6% of the BS patients. The success rate was 77% [mean number of percutaneous biliary interventions (PBIs) = 3.9 ± 1.98, median drainage time = 8 months]. In conclusion, BL patients can be managed with conservative therapy, even though most of these patients will ultimately be treated with surgery. Diagnosing a BS requires a high degree of clinical suspicion because the available resources for its identification can fail in up to 50% of cases. A higher number of PBIs and the use of a drainage catheter for a longer time may be required to achieve better results with this technique. © 2014 American Association for the Study of Liver Diseases.
Ultrasound-guided transhepatic puncture of the hepatic veins for TIPS placement.
Gazzera, C; Fonio, P; Gallesio, C; Camerano, F; Doriguzzi Breatta, A; Righi, D; Veltri, A; Gandini, G
2013-04-01
This retrospective analysis was carried out to assess the feasibility and results of transjugular intrahepatic portal systemic shunt (TIPS) performed with ultrasound (US)-guided percutaneous puncture of the hepatic veins. Over a period of 3 years, 153 patients were treated with TIPS at our centre. In eight cases, a percutaneous puncture of the middle (n=7) or right (n=1) hepatic vein was required because the hepatic vein ostium was not accessible. Indications for TIPS were bleeding (n=1), Budd-Chiari syndrome (n=1), ascites (n=2), reduced portal flow (n=1) and incomplete portal thrombosis (n=3). A 0.018-in. guidewire was anterogradely introduced into the hepatic vein to the inferior vena cava (IVC) through a 21-gauge needle. In the meantime, a 25-mm snare-loop catheter was introduced through the jugular access to retrieve the guidewire, achieving through-andthrough access. Then, a Rosch-Uchida set was used to place the TIPS with the traditional technique. Technical success was achieved in all patients. There was one case of stent thrombosis. One patient died of pulmonary oedema. Three patients were eligible for liver transplantation, whereas the others were excluded due to shunt thrombosis (n=1) and previous nonhepatic neoplasms (n=3). The percutaneous approach to hepatic veins is rapid and safe and may be useful for avoiding traumatic liver injuries.
Percutaneous aspiration of fluid for management of peritonitis in space
NASA Technical Reports Server (NTRS)
Kirkpatrick, A. W.; Nicolaou, S.; Campbell, M. R.; Sargsyan, A. E.; Dulchavsky, S. A.; Melton, S.; Beck, G.; Dawson, D. L.; Billica, R. D.; Johnston, S. L.;
2002-01-01
BACKGROUND: As a medical emergency that can affect even well-screened, healthy individuals, peritonitis developing during a long-duration space exploration mission may dictate deviation from traditional clinical practice due to the absence of otherwise indicated surgical capabilities. Medical management can treat many intra-abdominal processes, but treatment failures are inevitable. In these circumstances, percutaneous aspiration under sonographic guidance could provide a "rescue" strategy. Hypothesis: Sonographically guided percutaneous aspiration of intra-peritoneal fluid can be performed in microgravity. METHODS: Investigations were conducted in the microgravity environment of NASA's KC-135 research aircraft (0 G). The subjects were anesthetized female Yorkshire pigs weighing 50 kg. The procedures were rehearsed in a terrestrial animal lab (1 G). Colored saline (500 mL) was introduced through an intra-peritoneal catheter during flight. A high-definition ultrasound system (HDI-5000, ATL, Bothell, WA) was used to guide a 16-gauge needle into the peritoneal cavity to aspirate fluid. RESULTS: Intra-peritoneal fluid collections were easily identified, distinct from surrounding viscera, and on occasion became more obvious during weightless conditions. Subjectively, with adequate restraint of the subject and operators, the procedure was no more demanding than during the 1-G rehearsals. CONCLUSIONS: Sonographically guided percutaneous aspiration of intra-peritoneal fluid collections is feasible in weightlessness. Treatment of intra-abdominal inflammatory conditions in spaceflight might rely on pharmacological options, backed by sonographically guided percutaneous aspiration for the "rescue" of treatment failures. While this risk mitigation strategy cannot guarantee success, it may be the most practical option given severe resource limitations.
Spiliopoulos, S; Katsanos, K; Diamantopoulos, A; Karnabatidis, D; Siablis, D
2011-05-01
To present the results of a prospective, randomized, single-centre study investigating local anaesthesia before percutaneous common femoral artery (CFA) puncture and catheterization with the use of ultrasound-guided injection of lidocaine versus standard infiltration by manual palpation. Patients scheduled to undergo diagnostic or therapeutic transfemoral catheter-based procedures gave informed consent and were randomized in two groups. In the first arm local anaesthesia with lidocaine hydrochloride 1% was performed under ultrasound guidance (group U/S), while in the second arm the standard method of manual artery palpation was applied (group M). In both groups, subsequent CFA catheterization was achieved under ultrasound guidance. The primary study endpoint was peri-procedural pain level evaluated with a visual-analogue scale (VAS score 0-10). Between January 2009 and 2010, 200 patients (161 men, mean age 63±12 years) were equally assigned to each group without any significant differences in baseline demographics. Patients in group U/S experienced significantly less pain during CFA catheterization in comparison with group M with a difference of three points in mean VAS score reported (1.6±1.6 versus 4.6±1.9, p<0.0001). In addition, significantly less volume of lidocaine was used in group U/S compared to group M (16±2.7 versus 19±0.8ml, p<0.001).Total vascular access time was similar in both groups (4.4±1.3 versus 4.5±1.3min). Overall complications included two small groin haematomas in each group. Ultrasound-guided local anaesthesia of the CFA prior to percutaneous transcatheter procedures is safe and achieves superior levels of analgesia with minimal patient pain and discomfort compared to the standard method of manual palpation. Copyright © 2011 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
[Percutaneous ultrasound-guided drainage in the surgical treatment of acute severe pancreatitis].
Delattre, J-F; Levy Chazal, N; Lubrano, D; Flament, J-B
2004-11-01
To report results of percutaneous ultrasound-guided drainage, performed by a surgeon, in the treatment of complications of acute pancreatitis (AP), and to determine the role of this technique in the therapeutic armamentarium of severe AP. From 1986 to 2001, 59 patients were included in this retrospective study. All patients initially had severe necrotizing AP (mean Ranson score = 4.1 ; range : 2-7). Anatomical lesions included pancreatic abscess in 6 patients and necrosis in 53 (17 stage D and 36 stage E according to Balthazar's classification). Necrosis was infected in 42 and sterile in 11 respectively. Drainage was performed under ultrasound guidance and local anaesthesia using small-diameter drains (7-14 French). Drainage was performed on average 23 days after onset of AP. Infection was proven by fine-needle aspiration in 47 (80 %) patients (41 infected necrosis and 6 localized abscess). In one patient, culture of aspirated fluid was negative but necrosis was infected (one false negative). Culture of aspirated fluid was negative and necrosis was sterile in 11 patients. Nineteen (32%) patients healed without subsequent surgery: 7 (16%) in the infected necrosis group, 6(55%) in the sterile necrosis group, and 6 (100%) in the abscess group. Forty (68%) patients had subsequent necrosectomy including 8 (14%) who died. Twenty (34 %) digestive fistulas healed spontaneously, except one treated by diversion stomia. Of the 16 (27 %) pancreatic fistulas, 6 needed subsequent interventional treatment. In selected patients, percutaneous drainage can represent an alternative to surgery with a 14% mortality rate. The high rate of subsequent necrosectomy suggests that drains with larger diameter, possibly associated with continuous irrigation, should be used.
Kuo, P C; Lewis, W D; Stokes, K; Pleskow, D; Simpson, M A; Jenkins, R L
1994-08-01
Biliary complications (BC) remain a significant cause of morbidity and mortality after orthotopic liver transplantation (OLT). In an effort to determine the incidence of BC after OLT and the success of management options, 157 hepatic transplants performed from January 1987 to July 1991 were reviewed. The incidence of BC was 25 percent, with a one year mortality rate of 43.5 percent compared with 23.4 percent for patients in a control group (p < 0.05). Most BC occurring before postoperative day 30 presented as leaks, with a one year mortality rate of 50 percent (p < 0.03 versus control group). Biliary complications presenting after postoperative day 30 presented as strictures, with a one year mortality rate of 36.8 percent (p = NS versus control group). Endoscopic retrograde cholangiopancreatography (ERCP), percutaneous transhepatic cholangiography (PTHC), and operative treatment were analyzed to determine relative patency rates after intervention for BC. The analysis showed that ERCP and PTHC were equivalent, with a one year patency rate of 45 percent. Operative treatment had a patency rate of 89 percent (p < 0.05 compared to ERCP and PTHC). The results from ERCP and PTHC may be useful for delineation of rejection versus BC after OLT. However, operative treatment is significantly more effective for definitive treatment of BC after OLT.
Interstitial ablation and imaging of soft tissue using miniaturized ultrasound arrays
NASA Astrophysics Data System (ADS)
Makin, Inder R. S.; Gallagher, Laura A.; Mast, T. Douglas; Runk, Megan M.; Faidi, Waseem; Barthe, Peter G.; Slayton, Michael H.
2004-05-01
A potential alternative to extracorporeal, noninvasive HIFU therapy is minimally invasive, interstitial ultrasound ablation that can be performed laparoscopically or percutaneously. Research in this area at Guided Therapy Systems and Ethicon Endo-Surgery has included development of miniaturized (~3 mm diameter) linear ultrasound arrays capable of high power for bulk tissue ablation as well as broad bandwidth for imaging. An integrated control system allows therapy planning and automated treatment guided by real-time interstitial B-scan imaging. Image quality, challenging because of limited probe dimensions and channel count, is aided by signal processing techniques that improve image definition and contrast. Simulations of ultrasonic heat deposition, bio-heat transfer, and tissue modification provide understanding and guidance for development of treatment strategies. Results from in vitro and in vivo ablation experiments, together with corresponding simulations, will be described. Using methods of rotational scanning, this approach is shown to be capable of clinically relevant ablation rates and volumes.
Zidi, S; Prat, F; Le Guen, O; Rondeau, Y; Rocher, L; Fritsch, J; Choury, A; Pelletier, G
1999-01-01
Background—Magnetic resonance cholangiography (MRC) is a new technique for non-invasive imaging of the biliary tract. Aim—To assess the results of MRC in patients with suspected bile duct stones as compared with those obtained with reference imaging methods. Patients/Methods—70 patients (34 men and 36 women, mean (SD) age 71 (15.5) years; median 75) with suspected bile duct stones were included (cholangitis, 33; pancreatitis, three; suspected post-cholecystectomy choledocholithiasis, nine; cholestasis, six; stones suspected on ultrasound or computed tomography scan, 19). MR cholangiograms with two dimensional turbo spin echo sequences were acquired. Endoscopic retrograde cholangiography with or without sphincterotomy (n = 63), endosonography (n = 5), or intraoperative cho- langiography (n = 2) were the reference imaging techniques used for the study and were performed within 12 hours of MRC. Radiologists were blinded to the results of endoscopic retrograde cholangiography and previous investigations. Results—49 patients (70%) had bile duct stones on reference imaging (common bile duct, 44, six of which impacted in the papilla; intrahepatic, four; cystic duct stump, one). Stone size ranged from 1 to 20 mm (mean 6.1, median 5.5). Twenty seven patients (55%) had bile duct stones smaller than 6 mm. MRC diagnostic accuracy for bile duct lithiasis was: sensitivity, 57.1%; specificity, 100%; positive predictive value, 100%; negative predictive value, 50%. Conclusions—Stones smaller than 6 mm are still often missed by MRC when standard equipment is used. The general introduction of new technical improvements is needed before this method can be considered reliable for the diagnosis of bile duct stones. Keywords: bile duct calculi; endoscopic retrograde cholangiography; magnetic resonance cholangiography PMID:9862837
Ethnicity influences pain after ultrasound-guided percutaneous liver biopsy.
Mahadeva, Sanjiv; Mahfudz, Anis S; Vijayananthan, Anushya
2015-12-01
The influence of ethnicity on pain complicating ultrasound-guided percutaneous liver biopsy (US-guided PLB) and its clinical impact has not been reported to date. Consecutive adults from a multiethnic background, undergoing an US-guided PLB, were independently assessed for pain up to 6 h after the procedure. Clinical and demographic parameters were analysed to determine independent predictors of significant pain after PLB. Willingness to undergo a repeat procedure was assessed 1 week after PLB. Data from 203 patients (median age 50 years; 43.9% female; ethnicity: Malay 41.5%, Chinese 40%, Indian 18%; median BMI 27.7 kg/m; median waist circumference 92.0 cm) were analysed. Pain after US-guided PLB was experienced in 133 (61.1%) patients, with severity grades as follows: none, n=81 (39.9%); mild, n=56 (27.6%); moderate, n=51 (25.1%); and severe, n=15 (7.4%). Analgesia requirements correlated well with severity of pain. Independent predictors of significant pain after PLB (moderate and severe categories) in patients included age less than 50 years [odds ratio (OR) 3.0], female sex (OR 3.7), Indian ethnicity (OR 2.9) and Malay ethnicity (OR 2.7), but not number of needle passes, BMI and educational levels. Patients who experienced moderate/severe pain were less willing to undergo a repeat PLB compared with those who experienced mild/no pain (60.9 vs. 82.8%, P=0.001). Ethnicity has an important role in the development of pain after US-guided PLB. This has a significant impact on willingness to repeat the procedure.
Desai, Jamsheed A; Almekhlafi, Mohammed A; Hill, Michael D; Goyal, Mayank; Eesa, Muneer
2014-04-01
A middle aged patient presented with acute ischemic stroke due to basilar artery occlusion. The patient clinically deteriorated despite intravenous thrombolysis and was referred for mechanical thrombectomy. The right vertebral artery was occluded and could not be accessed despite attempting various shaped catheters, even when a radial artery access was used. The left vertebral artery ended in the posterior inferior cerebellar artery. Eventually, ultrasound guided V3 segment vertebral artery direct puncture was successfully done and the procedure was completed. No access related complications were encountered. Direct cervical arterial puncture can be safely used by experienced operators as a last resort in acute stroke cases with difficult access.
Breast abscess: evidence based management recommendations.
Lam, Elaine; Chan, Tiffany; Wiseman, Sam M
2014-07-01
Literature review was carried out and studies reporting on treatment of breast abscesses were critically appraised for quality and their level of evidence using the Strength of Recommendation Taxonomy guidelines, and key recommendations were summarized. Needle aspiration either with or without ultrasound guidance should be employed as first line treatment of breast abscesses. This approach has the potential benefits of: superior cosmesis, shorter healing time, and avoidance of general anaesthesia. Multiple aspiration sessions may be required for cure. Ultrasound-guided percutaneous catheter placement may be considered as an alternative approach for treatment of larger abscesses (>3 cm). Surgical incision and drainage should be considered for first line therapy in large (>5 cm), multiloculated, or long standing abscesses, or if percutaneous drainage is unsuccessful. All patients should be treated concurrently with antibiotics. Patients with recurrent subareolar abscesses and fistulas should be referred for consideration of surgical treatment.
Nam, Chang-Wook; Yoon, Hyuck-Jun; Cho, Yun-Kyeong; Park, Hyoung-Seob; Kim, Hyungseop; Hur, Seung-Ho; Kim, Yoon-Nyun; Chung, In-Sung; Koo, Bon-Kwon; Tahk, Seung-Jae; Fearon, William F; Kim, Kwon-Bae
2010-08-01
This study sought to evaluate the long-term clinical outcomes of a fractional flow reserve (FFR)-guided percutaneous coronary intervention (PCI) strategy compared with intravascular ultrasound (IVUS)-guided PCI for intermediate coronary lesions. Both FFR- and IVUS-guided PCI strategies have been reported to be safe and effective in intermediate coronary lesions. The study included 167 consecutive patients, with intermediate coronary lesions evaluated by FFR or IVUS (FFR-guided, 83 lesions vs. IVUS-guided, 94 lesions). Cutoff value of FFR in FFR-guided PCI was 0.80, whereas that for minimal lumen cross sectional area in IVUS-guided PCI was 4.0 mm(2). The primary outcome was defined as a composite of major adverse cardiac events including death, myocardial infarction, and ischemia-driven target vessel revascularization at 1 year after the index procedure. Baseline percent diameter stenosis and lesion length were similar in both groups (51 +/- 8% and 24 +/- 12 mm in the FFR group vs. 52 +/- 8% and 24 +/- 13 mm in the IVUS group, respectively). However, the IVUS-guided group underwent revascularization therapy significantly more often (91.5% vs. 33.7%, p < 0.001). No significant difference was found in major adverse cardiac event rates between the 2 groups (3.6% in FFR-guided PCI vs. 3.2% in IVUS-guided PCI). Independent predictors for performing intervention were guiding device: FFR versus IVUS (relative risk [RR]: 0.02); left anterior descending coronary artery versus non-left anterior descending coronary artery disease (RR: 5.60); and multi- versus single-vessel disease (RR: 3.28). Both FFR- and IVUS-guided PCI strategy for intermediate coronary artery disease were associated with favorable outcomes. The FFR-guided PCI reduces the need for revascularization of many of these lesions. Copyright (c) 2010 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Räber, Lorenz; Mintz, Gary S; Koskinas, Konstantinos C; Johnson, Thomas W; Holm, Niels R; Onuma, Yoshinubo; Radu, Maria D; Joner, Michael; Yu, Bo; Jia, Haibo; Menevau, Nicolas; de la Torre Hernandez, Jose M; Escaned, Javier; Hill, Jonathan; Prati, Francesco; Colombo, Antonio; di Mario, Carlo; Regar, Evelyn; Capodanno, Davide; Wijns, William; Byrne, Robert A; Guagliumi, Giulio
2018-05-22
This Consensus Document is the first of two reports summarizing the views of an expert panel organized by the European Association of Percutaneous Cardiovascular Interventions (EAPCI) on the clinical use of intracoronary imaging including intravascular ultrasound (IVUS) and optical coherence tomography (OCT). The first document appraises the role of intracoronary imaging to guide percutaneous coronary interventions (PCIs) in clinical practice. Current evidence regarding the impact of intracoronary imaging guidance on cardiovascular outcomes is summarized, and patients or lesions most likely to derive clinical benefit from an imaging-guided intervention are identified. The relevance of the use of IVUS or OCT prior to PCI for optimizing stent sizing (stent length and diameter) and planning the procedural strategy is discussed. Regarding post-implantation imaging, the consensus group recommends key parameters that characterize an optimal PCI result and provides cut-offs to guide corrective measures and optimize the stenting result. Moreover, routine performance of intracoronary imaging in patients with stent failure (restenosis or stent thrombosis) is recommended. Finally, strengths and limitations of IVUS and OCT for guiding PCI and assessing stent failures and areas that warrant further research are critically discussed.
Traumatic Gallbladder Rupture Treated by Laparoscopic Cholecystectomy
Egawa, Noriyuki; Ueda, Junji; Hiraki, Masatsugu; Ide, Takao; Inoue, Satoshi; Sakamoto, Yuichiro; Noshiro, Hirokazu
2016-01-01
Abstract Gallbladder rupture due to blunt abdominal injury is rare. There are few reports of traumatic gallbladder injury, and it is commonly associated with other concomitant visceral injuries. Therefore, it is difficult to diagnose traumatic gallbladder rupture preoperatively when it is caused by blunt abdominal injury. We report a patient who underwent laparoscopic cholecystectomy after an exact preoperative diagnosis of traumatic gallbladder rupture. A 43-year-old man was admitted to our hospital due to blunt abdominal trauma. The day after admission, abdominal pain and ascites increased and a muscular defense sign appeared. Percutaneous drainage of the ascites was performed, and the aspirated fluid was bloody and almost pure bile. He was diagnosed with gallbladder rupture by the cholangiography using the endoscopic retrograde cholangiopancreatography technique. Laparoscopic cholecystectomy was performed safely, and he promptly recovered. If accumulated fluids contain bile, endoscopic cholangiography is useful not only to diagnose gallbladder injury but also to determine the therapeutic strategy. PMID:27462188
MLESAC Based Localization of Needle Insertion Using 2D Ultrasound Images
NASA Astrophysics Data System (ADS)
Xu, Fei; Gao, Dedong; Wang, Shan; Zhanwen, A.
2018-04-01
In the 2D ultrasound image of ultrasound-guided percutaneous needle insertions, it is difficult to determine the positions of needle axis and tip because of the existence of artifacts and other noises. In this work the speckle is regarded as the noise of an ultrasound image, and a novel algorithm is presented to detect the needle in a 2D ultrasound image. Firstly, the wavelet soft thresholding technique based on BayesShrink rule is used to denoise the speckle of ultrasound image. Secondly, we add Otsu’s thresholding method and morphologic operations to pre-process the ultrasound image. Finally, the localization of the needle is identified and positioned in the 2D ultrasound image based on the maximum likelihood estimation sample consensus (MLESAC) algorithm. The experimental results show that it is valid for estimating the position of needle axis and tip in the ultrasound images with the proposed algorithm. The research work is hopeful to be used in the path planning and robot-assisted needle insertion procedures.
Needle biopsy for hepatic vitamin A levels in lions (Panthera leo).
Shamir, Merav H; Rubin, Gal; Aizenberg, Zachi; Berkovich, Zipi; Reifen, Ram; Horowitz, Igal; Bdolah-Abram, Tali; Aroch, Itamar
2012-06-01
Hypovitaminosis A (HA)-related skull malformations resulting in neurologic abnormalities and death have been, and still are, reported in captive lions (Panthera leo) worldwide. Liver vitamin A (VA) concentration is the most reliable indicator of animals' VA status, and its assessment is essential in prevention and treatment of HA in lions. A percutaneous needle liver biopsy using high-performance liquid chromatography ultraviolet retinoid analysis for VA concentration measurement was validated. It was first assessed in vitro using chicken liver. Later, the safety and feasibility of ultrasound-guided percutaneous needle liver biopsy was assessed in living lions. Hepatic VA concentrations in lion liver were measured using the above laboratory method. Mean chicken hepatic VA concentration in needle biopsy (NB) and wedge biopsy (WB) of the same liver lobes were 108.66 and 60.89 microg/g wet tissue, respectively, and were significantly (P = 0.03) correlated (r = 0.74). The calculated linear regression for predicting VA concentration in WB using NB VA for chicken liver was 25.194 + 0.3234x NB (microg/g). Four ultrasound-guided percutaneous needle liver biopsies were obtained from each of the four lions under general anesthesia. Mean hepatic VA concentration was 8.25 microg/g wet tissue (range 1.43-25.29 microg/g). Mean serum VA concentration, measured in these four lions was 1,011.1 nmol/L with a standard deviation of 337.91 nmol/L (range 590.26-1,077.2 nmol/L). The lions recovered uneventfully, and no complications were observed during a 4-yr follow-up period. In conclusion, the percutaneous needle liver biopsy technique is a reliable, practical, safe tool for obtaining liver tissue samples antemortem for assessment of the VA status in lions and can be used in future studies.
de-Miguel-Valtierra, Lorena; Salom-Moreno, Jaime; Fernández-de-Las-Peñas, César; Cleland, Joshua A; Arias-Buría, José L
2018-05-16
This randomized clinical trial compared the effects of adding US-guided percutaneous electrolysis into a program consisting of manual therapy and exercise on pain, related-disability, function and pressure sensitivity in subacromial pain syndrome. Fifty patients with subacromial pain syndrome were randomized into manual therapy and exercise or percutaneous electrolysis group. All patients received the same manual therapy and exercise program, one session per week for 5 consecutive weeks. Patients assigned to the electrolysis group also received the application of percutaneous electrolysis at each session. The primary outcome was Disabilities of the Arm, Shoulder and Hand (DASH). Secondary outcomes included pain, function (Shoulder Pain and Disability Index-SPADI) pressure pain thresholds (PPTs) and Global Rating of Change (GROC). They were assessed at baseline, post-treatment, and 3, and 6 months after treatment. Both groups showed similar improvements in the primary outcome (DASH) at all follow-ups (P=0.051). Subjects receiving manual therapy, exercise, and percutaneous electrolysis showed significantly greater changes in shoulder pain (P<0.001) and SPADI (P<0.001) than those receiving manual therapy and exercise alone at all follow-ups. Effect sizes were large (SMD>0.91) for shoulder pain and function at 3 and 6 months in favour of the percutaneous electrolysis group. No between-groups differences in PPT were found. The current clinical trial found that the inclusion of US-guided percutaneous electrolysis in combination with manual therapy and exercise resulted in no significant differences for related-disability (DASH) than the application of manual therapy and exercise alone in patients with subacromial pain syndrome. Nevertheless, differences were reported for some secondary outcomes such as shoulder pain and function (SPADI). Whether or not these effects are reliable should be addressed in future studies Perspective This study found that the inclusion of US-guided percutaneous electrolysis into a manual therapy and exercise program resulted in no significant differences for disability and pressure pain sensitivity than the application of manual therapy and exercise alone in patients with subacromial pain syndrome. Copyright © 2018. Published by Elsevier Inc.
[Choledocholithiasis and pregnancy. Hybrid laparo-endoscopic treatment in one step].
Valadez-Caballero, David; González-Santamaría, Roberto; Soto-Mendoza, Héctor; Alberto Blanco-Figueroa, Jorge; Flores-Pantoja, Juan Manuel
2014-01-01
Complications associated with choledocholithiasis are uncommon during pregnancy. However, when it occurs, the morbidity and mortality related for the product and the mother increases, so a proper treatment is imperative in these patients. A 25-year-old pregnant woman on her second trimester. The current condition was started four days prior to the hospital admission with abdominal pain in the right upper quadrant with nausea and vomit.Twenty-four hours later jaundice and dark urine is observed. Physical examination shows scleral jaundice, right upper quadrant abdominal pain without peritoneal irritation. Uterus at umbilicus level without uterine activity. Uterus at umbilicus level without uterine activity. Laboratory tests showed elevated bilirubin and transaminases without leukocytosis; ultrasound reported live intrauterine unique product, with a heart rate of 128 beats per minute, gallbladder with multiple images inside that cast acoustic shadowing, and a 10 mm common bile duct dilated bile duct with dilatation of intrahepatic bile ducts. It was perform laparoscopic cholecystectomy with intraoperative cholangiography and placement of a transcystic jaguar guide for selective cannulation of the common bile duct. Intraoperative endoscopic retrograde cholangiopancreatography was performed with endoscopic stone extraction. The outcome was satisfactory with a hospital discharge at 48 hours. Current evidence has shown that the combined use of laparoscopy and therapeutic endoscopic cholangiography in one step is effective for the treatment of choledocholithiasis, decreasing the risk of complications associated with cannulation of the bile duct.
Pancreatic acinar cell carcinoma extending into the common bile and main pancreatic ducts.
Yamaguchi, Rin; Okabe, Yoshinobu; Jimi, Atsuo; Shiota, Koji; Kodama, Takahito; Naito, Yoshiki; Yasunaga, Masafumi; Kinoshita, Hisafumi; Kojiro, Masamichi
2006-10-01
Acinar cell carcinoma (ACC) of the pancreas is relatively rare, accounting for only approximately 1% of all exocrine pancreatic tumors. A 69-year-old man was found to have a mass lesion measuring approximately 4 cm in diameter in the pancreatic head on ultrasound, abdominal dynamic CT, and percutaneous transhepatic cholangiography. Magnetic resonance cholangiopancreatography showed defect of the lower common bile duct (CBD) due to obstruction by the tumor cast. Histopathologically, the pancreatic head tumor invaded the main pancreatic duct (MPD) and CBD with extension into the CBD in a form of tumor cast. The tumor cells consisted of a solid proliferation with abundant eosinophilic cytoplasm and round nuclei in an acinar and trabecular fashion. A 55-year-old man with upper abdominal pain and nausea, had a cystic lesion approximately 3 cm in size in the pancreatic tail on CT. Histopathologically, the tumor was encapsulated by fibrous capsule and had extensive central necrosis with solid areas in the tumor periphery, and invaded with extension into the MPD in a form of tumor cast. The tumor cells resembled acinar cells in solid growths. Two resected cases of ACC with unusual tumor extension into the CBD and the MPD, respectively, are reported.
Ultrasound guided percutaneous cholecystostomy in high-risk patients for surgical intervention.
Bakkaloglu, Huseyin; Yanar, Hakan; Guloglu, Recep; Taviloglu, Korhan; Tunca, Fatih; Aksoy, Murat; Ertekin, Cemalettin; Poyanli, Arzu
2006-11-28
To assess the efficacy and safety of ultrasound guided percutaneous cholecystostomy (PC) in the treatment of acute cholecystitis in a well-defined high risk patients under general anesthesia. The data of 27 consecutive patients who underwent percutaneous transhepatic cholecystostomy for the management of acute cholecystitis from January 1999 to June 2003 was retrospectively evaluated. All of the patients had both clinical and sonographic signs of acute cholecystitis and had comorbid diseases. Ultrasound revealed gallbladder stones in 25 patients and acalculous cholecystitis in two patients. Cholecystostomy catheters were removed 14-32 d (mean 23 d) after the procedure in cases where complete regression of all symptoms was achieved. There were statistically significant reductions in leukocytosis, (13.7 x 10(3)+/-1.3 x 10(3) microg/L vs 13 x 10(3)+/-1 x 10(3) microg/L, P < 0.05 for 24 h after PC; 13.7 x 10(3)+/-1.3 x 10(3) microg/L vs 8.3 x 10(3)+/-1.2 x 10(3) microg/L, P < 0.0001 for 72 h after PC), C -reactive protein (51.2+/-18.5 mg/L vs 27.3+/-10.4 mg/L, P < 0.05 for 24 h after PC; 51.2+/-18.5 mg/L vs 5.4+/-1.5 mg/L, P < 0.0001 for 72 h after PC), and fever (38+/-0.35 centigrade vs 37.3+/-0.32 centigrade, P < 0.05 for 24 h after PC; 38+/-0.35 centigrade vs 36.9+/-0.15 centigrade, P < 0.0001 for 72 h after PC). Sphincterotomy and stone extraction was performed successfully with endoscopic retrograde cholangio-pancreatography (ERCP) in three patients. After cholecystostomy, 5 (18%) patients underwent delayed cholecystectomy without any complications. Three out of 22 patients were admitted with recurrent acute cholecystitis during the follow-up and recovered with medical treatment. Catheter dislodgement occurred in three patients spontaneously, and two of them were managed by reinsertion of the catheter. As an alternative to surgery, percutaneous cholecystostomy seems to be a safe method in critically ill patients with acute cholecystitis and can be performed with low mortality and morbidity. Delayed cholecystectomy and ERCP, if needed, can be performed after the acute period has been resolved by percutaneous cholecystostomy.
Cystic adventitial degeneration: ectopic ganglia from adjacent joint capsules.
Ortmann, J; Widmer, M K; Gretener, S; Do, D D; Willenberg, T; Daliri, A; Baumgartner, I
2009-11-01
Cystic adventitial degeneration is a rare non-atherosclerotic cause of peripheral arterial occlusive disease, mainly seen in young men without other evidence of vascular disease. Diagnosis will be established by clinical findings and by ultrasound or angiography and can be treated by excision or enucleation of the affected arterial segment or by percutaneous ultrasound-guided aspiration. However, the etiology of adventitial cysts remains unknown. We report a case of cystic adventitial degeneration showing a connection between the joint capsule and the adventitial cyst, supporting the theory that cystic adventitial degeneration may represent ectopic ganglia from adjacent joint capsules.
Villard, P F; Vidal, F P; Hunt, C; Bello, F; John, N W; Johnson, S; Gould, D A
2009-11-01
We present here a simulator for interventional radiology focusing on percutaneous transhepatic cholangiography (PTC). This procedure consists of inserting a needle into the biliary tree using fluoroscopy for guidance. The requirements of the simulator have been driven by a task analysis. The three main components have been identified: the respiration, the real-time X-ray display (fluoroscopy) and the haptic rendering (sense of touch). The framework for modelling the respiratory motion is based on kinematics laws and on the Chainmail algorithm. The fluoroscopic simulation is performed on the graphic card and makes use of the Beer-Lambert law to compute the X-ray attenuation. Finally, the haptic rendering is integrated to the virtual environment and takes into account the soft-tissue reaction force feedback and maintenance of the initial direction of the needle during the insertion. Five training scenarios have been created using patient-specific data. Each of these provides the user with variable breathing behaviour, fluoroscopic display tuneable to any device parameters and needle force feedback. A detailed task analysis has been used to design and build the PTC simulator described in this paper. The simulator includes real-time respiratory motion with two independent parameters (rib kinematics and diaphragm action), on-line fluoroscopy implemented on the Graphics Processing Unit and haptic feedback to feel the soft-tissue behaviour of the organs during the needle insertion.
Evaluating the Learning Curve for Percutaneous Nephrolithotomy under Total Ultrasound Guidance.
Song, Yan; Ma, YaNan; Song, YongSheng; Fei, Xiang
2015-01-01
To investigate the learning curve of percutaneous nephrolithotomy under total ultrasound guidance. One hundred and twenty consecutive PCNL operations under total ultrasound guidance performed by a novice surgeon in a tertiary referral center were studied. Operations were analyzed in cohorts of 15 to determine when a plateau was reached for the variables such as operation duration, ultrasound screening time, tract dilation time, stone-free rate and complication rate. Comparison was made with the results of a surgeon who had performed more than 1000 PCNLs. Fluoroscopy was not used at all during procedure. The mean operation time dropped from 82.5 min for the first 15 patients to a mean of 64.7 min for cases 46 through 60(P = 0.047). The ultrasound screening time was a peak of 6.4 min in the first 15 cases, whereas it dropped to a mean of 3.9 min for cases 46 through 60(P = 0.01). The tract dilation time dropped from 4.9 min for the first 15 patients to a mean of 3.8 min for cases 46 through 60(P = 0.036). The senior surgeon had a mean operating time, screening time and tract dilation time equivalent to those of the novice surgeon after 60 cases. There was no significant difference in stone free rate and complication rate. The competence of ultrasound guided PCNL is reached after 60 cases with good stone free rate and without major complications.
Mao, Feng; Dong, Yi; Ji, Zhengbiao; Cao, Jiaying; Wang, Wen-Ping
2017-01-01
Aim. To investigate the value of contrast-enhanced ultrasound (CEUS) guided biopsy of undetermined abdominal lesions in multidisciplinary treatment (MDT) decision-making approach. Methods. Between Jan 2012 and Dec 2015, 60 consecutive patients (male, 37; female, 23; mean age, 51.3 years ± 14.6) who presented with undetermined abdominal lesions were included. CEUS and core needle percutaneous biopsy was performed under real-time CEUS guidance in all lesions. Data were recorded and compared with conventional ultrasound (US) guidance group ( n = 75). All CEUS findings and clinical data were evaluated in MDT. Results. CEUS enabled the delimitation of more (88.3% versus 41.3%) and larger (14.1 ± 10.7 mm versus 32.3 ± 18.5 mm) nonenhanced necrotic areas. More inner (20.0% versus 6.7%) and surrounding (18.3% versus 2.7%) major vessels were visualized and avoided during biopsies. CEUS-guided biopsy increased the diagnostic accuracy from 93.3% to 98.3%, with correct diagnosis in 57 of 60 lesions (95.0%). The therapeutic plan was influenced by CEUS guided biopsies findings in the majority of patients (98.3%). Conclusion. The combination of CEUS guided biopsy and MDT decision-making approach is useful in the diagnostic work-up and therapeutic management.
Moreno, Carlos; Mattiussi, Gabriele; Núñez, Francisco J
2016-10-01
Rectus abdominis-related groin pain (RAGP) is one of the possible clinical patterns that determine pubalgia. RAGP is one of the typical patterns in footballers and is due to the degeneration and tendinopathy of the distal tendon, at the level of the two pubic tubercles. Intratissue percutaneous electrolysis (EPI) is a novel technique used in the treatment of tendinopathies. The aim of this study was to examine the therapeutic benefits of EPI by contrasting the two basic components that characterize RAGP: painful symptoms and resultant functional deficits. Eight professional footballers at Udinese Calcio Spa Football Club underwent ultrasound-guided EPI intervention. No other type of treatment was combined with EPI. Pain was monitored with the Verbal Rating Scale, while functional deficit was monitored using the Patient Specific Functional Scale. The scales implementation took place before treatment, then 24 hours, 1 week, 1 month and 6 months after the end of treatment. Treatment with EPI produced a complete reduction of pain symptoms in one month and enabled excellent functional recovery for walking and jogging in one week; for getting out of bed, running, jumping and kicking within one month from the end of the treatment. Treatment with ultrasound-guided EPI has shown encouraging clinical results for RAGP. Data are preliminary: considering the limitations of this study more complex design studies are necessary to test the efficacy of the technique. This study introduces the EPI technique for the first time in the treatment of professional footballers suffering from RAGP. Its future use is proposed as a treatment solution, including complementary to conservative treatment.
Ultrasound-guided chest biopsies.
Middleton, William D; Teefey, Sharlene A; Dahiya, Nirvikar
2006-12-01
Pulmonary nodules that are surrounded by aerated lung cannot be visualized with sonography. Therefore, percutaneous biopsy must be guided with computed tomography or fluoroscopy. Although this restriction only applies to central lung nodules, it has permeated referral patterns for other thoracic lesions and has retarded the growth of ultrasound-guided interventions. Nevertheless, sonography is an extremely flexible modality that can expeditiously guide many biopsy procedures in the thorax. Peripheral pulmonary nodules can be successfully biopsied with success rates exceeding 90% and complications rates of less than 5%. Orienting the probe parallel to the intercostal space facilitates biopsies of peripheral pulmonary nodules. Anterior mediastinal masses that extend to the parasternal region are often easily approachable provided the internal mammary vessels, costal cartilage, and deep great vessels are identified and avoided. Superior mediastinal masses can be sampled from a suprasternal or supraclavicular approach. Phased array probes or tightly curved arrays may provide improved access for biopsies in this location. Posterior mediastinal masses are more difficult to biopsy with ultrasound guidance because of the overlying paraspinal muscles. However, when posterior mediastinal masses extend into the posterior medial pleural region, they can be biopsied with ultrasound guidance. Because many lung cancers metastasize to the supraclavicular nodes, it is important to evaluate the supraclavicular region when determining the best approach to obtain a tissue diagnosis. When abnormal supraclavicular nodes are present, they often are the easiest and safest lesions to biopsy.
Falco, Giuseppe; Foroni, Monica; Castagnetti, Fabio; Marano, Luigi; Bordoni, Daniele; Rocco, Nicola; Marchesi, Vanessa; Iotti, Valentina; Vacondio, Rita; Ferrari, Guglielmo
2016-12-01
Management of breast abscess in lactating women remains controversial. During pregnancy, women may develop different kinds of benign breast lesions that could require a surgical incision performed under general anesthesia with consequent breastfeeding interruption. The purpose of this study was to prospectively evaluate the management of large breast abscesses with ultrasound-assisted drainage aiming at breastfeeding preservation. 34 lactating women with a diagnosis of unilateral breast abscess have been treated with an ultrasound (US)-assisted drainage of the abscess. A pigtail catheter was inserted into the fluid collection using the Seldinger technique under US guide and connected to a three stop way to allow drainage and irrigation of the cavity until its resolution. All procedures have been found safe and well tolerated. No recurrence was observed and breastfeeding was never interrupted. The described technique allows to avoid surgery and to preserve breastfeeding in well-selected patients with a safe, well-tolerated and cost-effective procedure.
Meroni, E; Bisagni, P; Bona, S; Fumagalli, U; Zago, M; Rosati, R; Malesci, A
2004-01-01
Pre-operative endosonography has been proposed as a cost-effective procedure in the management of patients who undergo laparoscopic cholecystectomy having an intermediate risk of common bile duct stones. We prospectively evaluated the impact of pre-operative endosonography on the management of patients facing laparoscopic cholecystectomy with abnormal liver function tests as the sole risk factor for choledocolithiasis. Among 587 consecutive patients scheduled for laparoscopic cholecystectomy, 47 (8%) patients having one or more abnormal liver function tests but a normal appearance of common bile duct at abdominal ultrasound, underwent pre-operative endosonography. In patients with endosonography-detected common bile duct stones, a pre-operative endoscopic retrograde cholangiography was performed, or an intra-operative endoscopic retrograde cholangiography was scheduled. In all endosonography-negative patients, an intra-operative trans-cystic cholangiography was performed. Endosonography detected common bile duct stones in nine patients (19%) but only in five of them stones were radiologically confirmed (PPV 0.55). Endosonography-detected stones were confirmed in four of four (100%) patients in whom cholangiography was performed within 1 week, but only in one of five (20%) patients in whom radiology was further delayed (P < 0.05). In three of four cases (75%), stones detected at endosonography but not confirmed at X-rays, were smaller than 2.0 mm. Among 38 patients with negative endosonography, common bile duct stones were found in two patients (NPV 0.95), whereas unplanned endoscopic stone extraction was needed only in one patient (NPV 0.97). Pre-operative endosonography can spare unnecessary pre-operative endoscopic retrograde cholangiography as well as inappropriate scheduling of intra-operative endoscopic retrograde cholangiography in patients undergoing laparoscopic cholecystectomy with abnormal liver function tests. To maximise the impact of endosonography on the management of these patients, the procedure should be performed immediately before laparoscopic cholecystectomy.
Emergency percutaneous treatment in surgical bile duct injury.
Carrafiello, Gianpaolo; Laganà, Domenico; Dizonno, Massimiliano; Ianniello, Andrea; Cotta, Elisa; Dionigi, Gianlorenzo; Dionigi, Renzo; Fugazzola, Carlo
2008-09-01
The aim of this study is to evaluate the efficacy of emergency percutaneous treatment in patients with surgical bile duct injury (SBDI). From May 2004 to May 2007, 11 patients (five men, six women; age range 26-80 years; mean age 58 years) with a critical clinical picture (severe jaundice, bile peritonitis, septic state) due to SBDI secondary to surgical or laparoscopic procedures were treated by percutaneous procedures. We performed four ultrasound-guided percutaneous drainages, four external-internal biliary drainages, one bilioplasty, and two plastic biliary stenting after 2 weeks of external-internal biliary drainage placement. All procedures had 100% technical success with no complications. The clinical emergencies resolved in 3-4 days in 100% of cases. All patients had a benign clinical course, and reoperation was avoided in 100% of cases. Interventional radiological procedures are effective in the emergency management of SBDI since they are minimally invasive and have a high success rate and a low incidence of complications compared to the more complex and dangerous surgical or laparoscopic options.
Menon, Arun S.; Nazar, P. K.; Moorthy, Srikanth; Kumar, Harish; Nair, Vasantha; Pavithran, Praveen Valiyaparambil; Bhavani, Nisha; Menon, Vadayath Usha; Abraham, Nithya; Jayakumar, R. Vasukutty
2017-01-01
A 30-year-old male with cerebral palsy and motor impairment presented with right femur fracture. He had gradually worsening mobility and contractures of all extremities for the preceding 5 years. Evaluation showed multiple vertebral and femoral fractures, severe osteoporosis, a large parathyroid adenoma, and parathormone (PTH) exceeding 2500 pg/mL. Because of poor general health and high anesthetic risk, parathyroidectomy was deemed impractical. Ultrasound-guided radiofrequency ablation (RFA) helped achieve 50% size reduction and PTH levels with better control of hypercalcemia. Later, as calcium and PTH remained elevated, percutaneous ethanol ablation was performed with resultant normalization of PTH and substantial symptomatic improvement. Two years later, he still remains normocalcaemic with normal PTH levels. We propose that RFA and percutaneous ethanol ablation be considered as effective short-term options for surgically difficult cases, which could even help achieve long-term remission. Although not previously reported, our case illustrates that both RFA and percutaneous ethanol ablation could be safely performed successively achieving long-term remission. PMID:29264521
Yamauchi, Hiroshi; Kida, Mitsuhiro; Imaizumi, Hiroshi; Okuwaki, Kosuke; Miyazawa, Shiro; Iwai, Tomohisa; Koizumi, Wasaburo
2015-01-01
Endoscopic retrograde cholangiopancreatography (ERCP) remains challenging in patients who have undergone surgical reconstruction of the intestine. Recently, many studies have reported that balloon-enteroscope-assisted ERCP (BEA-ERCP) is a safe and effective procedure. However, further improvements in outcomes and the development of simplified procedures are required. Percutaneous treatment, Laparoscopy-assisted ERCP, endoscopic ultrasound-guided anterograde intervention, and open surgery are effective treatments. However, treatment should be noninvasive, effective, and safe. We believe that these procedures should be performed only in difficult-to-treat patients because of many potential complications. BEA-ERCP still requires high expertise-level techniques and is far from a routinely performed procedure. Various techniques have been proposed to facilitate scope insertion (insertion with percutaneous transhepatic biliary drainage (PTBD) rendezvous technique, Short type single-balloon enteroscopes with passive bending section, Intraluminal injection of indigo carmine, CO2 inflation guidance), cannulation (PTBD or percutaneous transgallbladder drainage rendezvous technique, Dilation using screw drill, Rendezvous technique combining DBE with a cholangioscope, endoscopic ultrasound-guided rendezvous technique), and treatment (overtube-assisted technique, Short type balloon enteroscopes) during BEA-ERCP. The use of these techniques may allow treatment to be performed by BEA-ERCP in many patients. A standard procedure for ERCP yet to be established for patients with a reconstructed intestine. At present, BEA-ERCP is considered the safest and most effective procedure and is therefore likely to be recommended as first-line treatment. In this article, we discuss the current status of BEA-ERCP in patients with surgically altered gastrointestinal anatomy. PMID:26074685
Ultrasound-guided percutaneous fine-needle aspiration of 545 focal pancreatic lesions.
Zamboni, Giulia A; D'Onofrio, Mirko; Idili, Antonio; Malagò, Roberto; Iozzia, Roberta; Manfrin, Erminia; Mucelli, Roberto Pozzi
2009-12-01
The purpose of this study was to assess the accuracy and short-term complication rate of ultrasound-guided fine-needle aspiration cytologic sampling of focal pancreatic lesions. We reviewed 545 consecutive ultrasound-guided fine-needle aspiration cytologic sampling procedures for focal pancreatic lesions from January 2004 through June 2008. The procedures were performed with a 20- or 21-gauge needle. The onsite cytopathologist evaluated the appropriateness of the sample and made a diagnosis. We reviewed the final diagnosis and the radiologic and medical records of all patients for onset of complications during or within 7 days of the procedure. The study sample included 262 women and 283 men (mean age, 62 years; range, 25-86 years). The head or uncinate process of the pancreas was the location of 63.0% of the lesions, and 35.2% of the lesions were located in the body or tail of the pancreas. The site of 10 lesions (1.8%) was not specified. Sampling was diagnostic in 509 of the 545 cases (93.4%). Excluding the 36 nondiagnostic samples, ultrasound-guided fine-needle aspiration cytologic sampling had 99.4% sensitivity, 100% specificity, and 99.4% accuracy. In 537 of the 545 cases (98.5%), the procedure was uneventful. In two cases, abdominal fluid was found after the procedure that was not present before the procedure. Six patients experienced postprocedural pain without abnormal findings at subsequent imaging. No major complications occurred. Ultrasound-guided cytologic sampling is safe and accurate for the diagnosis and planning of management of focal pancreatic lesions. With a cytologist on site, the rate of acquisition of samples adequate for diagnosis is high, reducing the need for patient recall.
Role of ultrasonography in percutaneous renal access in patients with renal anatomic abnormalities.
Penbegul, Necmettin; Hatipoglu, Namik Kemal; Bodakci, Mehmet Nuri; Atar, Murat; Bozkurt, Yasar; Sancaktutar, Ahmet Ali; Tepeler, Abdulkadir
2013-05-01
To present our experience regarding the feasibility, safety, and efficacy of ultrasound (US)-guided percutaneous nephrolithotomy in anatomically abnormal kidneys. We performed US-guided percutaneous nephrolithotomy in 15 patients with anatomically abnormal kidneys and renal calculi. Of the 15 patients, 5 had horseshoe kidneys, 5 had rotation anomalies, 2 had kyphoscoliosis, and 3 had scoliosis. The stone size, number of access tracts, operative time, hospitalization duration, rate of stone clearance, and complication rate were recorded. Percutaneous access was achieved with US guidance in the operating room by the urologist. Successful renal access was obtained by the surgeon using US guidance in all patients, and a single access was obtained in all cases. Of the 15 patients, 8 were females, and 7 were males; 8 patients had solitary stones, and 7 had multiple calculi. The renal calculi were on the right in 7 patients and on the left in 8. Three patients had previously undergone unsuccessful shock wave lithotripsy. Complete stone clearance was achieved in 13 patients. The mean operative time was 54.2 minutes. No patient required a blood transfusion because of bleeding. Urinary tract infections occurred in 2 patients, who were treated with antibiotics. A double-J catheter was not inserted in any patient; however, a ureteral catheter was used in 3 patients for 1 day. None of the patients had any major complications during the postoperative period. The stone-free rate was 87%, and 2 patients had clinically insignificant residual fragments. Our results have demonstrated that US-guided percutaneous nephrolithotomy can be performed feasibly, safely, and effectively in anatomically abnormal kidneys. Copyright © 2013 Elsevier Inc. All rights reserved.
Percutaneous treatment of calculi in reconstructed bladder.
Paez, Edgar; Reay, Emma; Murthy, L N S; Pickard, Robert S; Thomas, David J
2007-03-01
To report our results with percutaneous removal of calculi from reconstructed bladders. Twelve patients with reconstructed bladders who underwent endoscopic cystolithotomy were identified from our departmental database, and retrospective review of case notes and imaging was performed. Access was gained via an ultrasound-guided new tract in 9 patients (75%). An old suprapubic tract site was used in two patients, and the Mitrofanoff stoma was the route of access in one patient. The procedure was successful, with stone clearance achieved in all 12 cases. No major complications were observed. At a median follow up of 24 months, stone recurrence was observed in 5 patients (42%), 4 of whom underwent repeat procedures. Follow-up showed no change in continence in the patient with a Mitroffanoff stoma. Percutaneous cystolithotomy is a safe and effective minimally invasive option for removal of stones in a reconstructed bladder. We recommend endoscopic removal as the treatment of choice in these patients.
Bas, Ahmet; Gülşen, Fatih; Emre, Senol; Samanci, Cesur; Uzunlu, Osman; Cantasdemir, Murat; Emir, Haluk; Numan, Furuzan
2015-12-01
Percutaneous nephrostomy (PCN) catheters are placed under combined ultrasound and fluoroscopic guidance in the interventional radiology suite and present unique challenges in neonates and infants. The purpose of this study was to demonstrate feasibility of PCN using a "14-4" (trocar and cannula) technique on neonates and infants. Between September 2009 and June 2014, data for 27 kidneys from consecutive 22 neonates or infants who underwent PCN catheter placement using the "14-4" technique were retrospectively analyzed. The median age at the time of placement of the PCN catheters was 11 days (range 5-300 days). There were 18 males and 4 females. All procedures were performed in the interventional radiology suite but without using fluoroscopy. Unilateral PCN was performed on 17 out of 22 patients, while bilateral drainage was performed on five patients. The technical success rate was 100%. The median duration of PCN catheter was 75 days (range 10-138 days). Minor macroscopic hematuria not requiring blood transfusion was present in two of the patients in which the hematuria lasted in 2 days. Placement of PCN catheters using a "14-4" technique with ultrasound as the sole imaging modality is a technically feasible and desirable option for neonates or infants. The technique obviates the need for ionizing radiation and potentially could be performed in the ultrasound room or even at the bedside.
Fidelman, Nicholas; Kerlan, Robert K; Laberge, Jeanne M; Gordon, Roy L
2011-06-01
To determine the ability of percutaneous transhepatic cholangiography (PTC) to predict accurately the anatomic location and nature of major bile duct injuries, to examine the contribution of endoscopic retrograde cholangiopancreatography (ERCP) and PTC to the diagnosis of injuries to the low-inserting right posterior segmental ducts, and to compare the ability of radiologists and gastroenterologists to detect injuries to the low-inserting right posterior segmental duct. PTC images and operative reports of 78 consecutive patients who underwent surgical repair of major bile duct injuries at the authors' institution were retrospectively reviewed. The location of injury was assessed according to the Bismuth classification. Images were also evaluated for the presence of a biliary stricture, biliary leak, or both. Imaging observations were compared with findings obtained during surgical biliary reconstruction. PTC correctly predicted the anatomic location of injuries in 85% of patients. Incorrect Bismuth type was assigned in 12 patients. Seven of the errors (58%) originated from the inability to distinguish injuries at the confluence of the lobar ducts from injuries involving the cephalad 2 cm of the common hepatic duct. Injuries to the right posterior segmental duct were detected more often on ERCP images by gastroenterologists than by diagnostic radiologists. In four patients (5%), biliary strictures were masked on PTC by the presence of a concomitant leak. PTC accurately depicts the location and nature of major bile duct injuries in most patients. Copyright © 2011 SIR. Published by Elsevier Inc. All rights reserved.
Percutaneous ultrasound-guided renal biopsy: A Libyan experience
Mishra, A.; Tarsin, R.; ElHabbash, B.; Zagan, N.; Markus, R.; Drebeka, S.; AbdElmola, K.; Shawish, T.; Shebani, A.; AbdElmola, T.; ElUsta, A.; Ehtuish, E. F.
2010-01-01
This study was done to assess the safety and efficacy of ultrasound-guided percutaneous renal biopsy (PRB), to ascertain the risk factors for complications and determine the optimal period of observation. The radiologist (A.M.) at the National Organ Transplant Centre, Central Hospital, Tripoli, Libya, performed 86 PRBs between February 1, 2006, and January 31, 2008, using an automated biopsy gun with 16-gauge needle. Coagulation profile was done in all the patients. All patients were kept on strict bed rest for six hours post-procedure. Eighty six renal biopsies were performed on 78 patients referred from rheumatology department and eight post-kidney transplant recipients; 23 were males with age range 15 – 56 years and 63 females with age range 16 – 66 years. A mean of 17.5 glomeruli were present in each specimen. A glomerular yield of less than five glomeruli was seen in four biopsies. Class I lupus nephritis (LN) was seen in 1 patient, class II lupus nephritis in 7 patients, class III LN in 13 patients and class IV LN in 29 patients. All the eight renal allografts were diagnosed as acute tubular necrosis or acute interstitial rejection. The risk of post-biopsy bleeding was higher in women, older patients and higher PTT. The overall complication rate was 5.8%. Three complications were observed within six hours of biopsy. No late complication was seen. PRB under real-time ultrasound-guidance is a safe and efficacious procedure to establish the histological diagnosis and should be done as out-patient procedure. Observation time of six hours post-biopsy is optimal. PMID:20835320
Gastric schwannoma presenting as a casual ultrasonographic findings.
Álvarez Higueras, Francisco Javier; Pereñíguez López, Ana; Estrella Díez, Esther; Muñoz Tornero, María; Egea Valenzuela, Juan; Bas Bernal, Águeda; Garre Sánchez, Carmen; Vargas Acosta, Ángel; Sánchez Velasco, Eduardo; Carballo Álvarez, Luis Fernando
2016-12-01
We present the case of a patient under study due to ascites in which a mass located on the gastric wall was observed during ultrasonography. Further studies (upper endoscopy and computed tomography) confirmed this finding. After an ultrasound-guided percutaneous biopsy, diagnosis of gastric schwannoma was made as intense S-100 expression was found. Surgery was rejected due to the bad clinical situation of the patient and because the mass was an asymptomatic benign tumor.
Interventional MSK procedures: the hip.
Dodré, Emilie; Lefebvre, Guillaume; Cockenpot, Eric; Chastanet, Patrick; Cotten, Anne
2016-01-01
Percutaneous musculoskeletal procedures are widely accepted as low invasive, highly effective, efficient and safe methods in a vast amount of hip pathologies either in diagnostic or in therapeutic management. Hip intra-articular injections are used for the symptomatic treatment of osteoarthritis. Peritendinous or intrabursal corticosteroid injections can be used for the symptomatic treatment of greater trochanteric pain syndrome and anterior iliopsoas impingement. In past decades, the role of interventional radiology has rapidly increased in metastatic disease, thanks to the development of many ablative techniques. Image-guided percutaneous ablation of skeletal metastases provides a minimally invasive treatment option that appears to be a safe and effective palliative treatment for localized painful lytic lesion. Methods of tumour destruction based on temperature, such as radiofrequency ablation (RFA) and cryotherapy, are performed for the management of musculoskeletal metastases. MR-guided focused ultrasound surgery provides a non-invasive alternative to these ablative methods. Cementoplasty is now widely used for pain management and consolidation of acetabular metastases and can be combined with RFA. RFA is also used to treat benign tumours, namely osteoid osteomas. New interventional procedures such as percutaneous screw fixation are also proposed to treat non-displaced or minimally displaced acetabular roof fractures.
Lungren, Matthew P; Lindquester, Will S; Seidel, Frank Glen; Kothary, Nishita; Monroe, Eric J; Shivaram, Giri; Gill, Anne E; Hawkins, Matthew C
2016-12-01
The aim of the study was to describe and assess the technical success and safety of ultrasound-guided liver biopsy with gelatin sponge pledget tract embolization technique in infants <10 kg across 3 tertiary pediatric hospitals. There were 67 pediatric patients weighing <10 kg (36 boys; 31 girls; average age 202 days; average weight 6 kg, range 1.5-9.9 kg) referred for liver biopsy performed with ultrasound guidance and gelatin sponge pledget tract embolization during a 2-year period. Patient history, procedural records, and clinical follow-up documents were retrospectively reviewed. A total of 67 procedures were included. There was 100% technical success rate and all samples obtained provided adequate tissue for histological assessment. Average number of 18 G biopsy passes was 3 (range 1-6). There were no procedure-related deaths. There was 1 complication (1%) in a 5-kg infant who was readmitted 36 hours after biopsy with a fever and fully recovered after antibiotics were administered. Biliary atresia was the most common underlying diagnosis (20%), whereas others included acute rejection (16%) and biliary obstruction (7%). Ultrasound-guided percutaneous liver biopsy with gelatin sponge pledget tract embolization technique in children weighing <10 kg is safe, effective, and use of this technique may lead to a reduction in rates of adverse events reported in other pediatric series.
Male breast cancer is rare: an initial presentation may be as an abscess.
Ventham, N T; Hussien, M I
2010-08-06
Breast cancer in men is rare. Breast cancer presenting initially as an abscess has been described only a handful of times in the literature. We present the first described case of invasive adenocarcinoma presenting as an abscess in a man. An 80-year-old diabetic man presented with symptoms typical of a breast abscess. The abscess failed to respond to percutaneous therapy and excision of breast abscess was performed. Histology revealed an invasive carcinoma. He went on to have a mastectomy. Histology should be obtained from breast abscesses not resolving within 2 months of initial percutaneous therapy. Histology could be obtained by ultrasound-guided fine-needle aspiration (FNA), core or vacuum assisted biopsy, or by formal incision and drainage.
Male breast cancer is rare: an initial presentation may be as an abscess
Ventham, N T; Hussien, M I
2010-01-01
Breast cancer in men is rare. Breast cancer presenting initially as an abscess has been described only a handful of times in the literature. We present the first described case of invasive adenocarcinoma presenting as an abscess in a man. An 80-year-old diabetic man presented with symptoms typical of a breast abscess. The abscess failed to respond to percutaneous therapy and excision of breast abscess was performed. Histology revealed an invasive carcinoma. He went on to have a mastectomy. Histology should be obtained from breast abscesses not resolving within 2 months of initial percutaneous therapy. Histology could be obtained by ultrasound-guided fine-needle aspiration (FNA), core or vacuum assisted biopsy, or by formal incision and drainage. PMID:22767683
Valera-Garrido, Fermín; Minaya-Muñoz, Francisco; Medina-Mirapeix, Francesc
2014-01-01
Background Ultrasound (US)-guided percutaneous needle electrolysis (PNE) is a novel minimally invasive approach which consists of the application of a galvanic current through an acupuncture needle. Objective To evaluate the clinical and ultrasonographic effectiveness of a multimodal programme (PNE, eccentric exercise (EccEx) and stretching) in the short term for patients with chronic lateral epicondylitis, and to determine whether the clinical outcomes achieved decline over time. Methods A one-way repeated measures study was performed in a clinical setting in 36 patients presenting with lateral epicondylitis. The patients received one session of US-guided PNE per week over 4–6 weeks, associated with a home programme of EccEx and stretching. The main outcome measures were severity of pain, disability (Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire), structural tendon changes (US), hypervascularity and patients’ perceptions of overall outcome. Measurements at 6, 26 and 52 weeks follow-up included recurrence rates (increase in severity of pain or disability compared with discharge), perception of overall outcome and success rates. Results All outcome measures registered significant improvements between pre-intervention and discharge. Most patients (n=30, 83.3%) rated the overall outcome as ‘successful’ at 6 weeks. The ultrasonographic findings showed that the hypoechoic regions and hypervascularity of the extensor carpi radialis brevis changed significantly. At 26 and 52 weeks, all participants (n=32) perceived a ‘successful’ outcome. Recurrence rates were null after discharge and at follow-up at 6, 26 and 52 weeks. Conclusions Symptoms and degenerative structural changes of chronic lateral epicondylitis are reduced after US-guided PNE associated with EccEx and stretching, with encouragingly low recurrences in the mid to long term. Trial registration number ClinicalTrials.gov identifier: NCT02085928. PMID:25122629
de la Cruz Torres, Blanca; Albornoz Cabello, Manuel; García Bermejo, Paula; Naranjo Orellana, José
2016-08-01
Ultrasound (US)-guided percutaneous needle electrolysis (PNE) is a novel minimally invasive approach, which involves the application of a galvanic current via an acupuncture needle. As in any procedure involving needling, vagal reactions have been reported during PNE. To examine for changes in autonomic activity during the US-guided PNE technique on healthy patellar tendons by measurement and analysis of heart rate variability (HRV). Twenty-two male footballers were randomly allocated to: a control group (11 players), for whom HRV was recorded for 10 min, both at rest and during an exhaustive US examination of the patellar tendon and adjacent structures; and an experimental group (11 players), for whom HRV was recorded for 10 min, both at rest and during application of US-guided PNE on the patellar tendon. The following HRV parameters were assessed: mean NN interval, mean heart rate, time domain parameters (SDNN, rMSSD, pNN50), diameters of the Poincaré plot (SD1, SD2), stress score, and sympathetic/parasympathetic ratio. There were no differences between groups in any baseline measurements, nor were there any significant differences between control group measurements (baseline vs intervention). The experimental group exhibited statistically significant increases in SDNN/SD1 (p=0.02/p=0.03) and SD2 (p=0.03), indicating increased parasympathetic and decreased sympathetic activity, respectively. US-guided PNE was associated with an autonomic imbalance characterised by greater parasympathetic activity, which could potentially result in a vasovagal reaction. Care should be taken to monitor for adverse reactions during US-guided PNE and simple HRV indicators may have a role in early detection. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Ablative therapy for liver tumours
Dick, E A; Taylor-Robinson, S D; Thomas, H C; Gedroyc, W M W
2002-01-01
Established ablative therapies for the treatment of primary and secondary liver tumours, including percutaneous ethanol injection, cryotherapy, and radiofrequency ablation, are discussed. Newer techniques such as magnetic resonance imaging guided laser interstitial thermal therapy of liver tumours has produced a median survival rate of 40.8 months after treatment. The merits of this newly emerging technique are discussed, together with future developments, such as focused ultrasound therapy, which holds the promise of non-invasive thermoablation treatment on an outpatient basis. PMID:11950826
Minimizing radiation exposure during percutaneous nephrolithotomy.
Chen, T T; Preminger, G M; Lipkin, M E
2015-12-01
Given the recent trends in growing per capita radiation dose from medical sources, there have been increasing concerns over patient radiation exposure. Patients with kidney stones undergoing percutaneous nephrolithotomy (PNL) are at particular risk for high radiation exposure. There exist several risk factors for increased radiation exposure during PNL which include high Body Mass Index, multiple access tracts, and increased stone burden. We herein review recent trends in radiation exposure, radiation exposure during PNL to both patients and urologists, and various approaches to reduce radiation exposure. We discuss incorporating the principles of As Low As reasonably Achievable (ALARA) into clinical practice and review imaging techniques such as ultrasound and air contrast to guide PNL access. Alternative surgical techniques and approaches to reducing radiation exposure, including retrograde intra-renal surgery, retrograde nephrostomy, endoscopic-guided PNL, and minimally invasive PNL, are also highlighted. It is important for urologists to be aware of these concepts and techniques when treating stone patients with PNL. The discussions outlined will assist urologists in providing patient counseling and high quality of care.
Liu, Baoxian; Zhou, Luyao; Huang, Guangliang; Zhong, Zhihai; Jiang, Chunlin; Shan, Quanyuan; Xu, Ming; Kuang, Ming; Xie, Xiaoyan
2015-01-01
This study aimed to summarize the first experience with ultrasound-guided percutaneous ablation treatment (PAT) for recurrent hepatoblastoma (HB) after liver resection in children. From August 2013 to October 2014, PAT was used to treat 5 children with a total of 8 recurrent HB (mean size, 1.4 ± 0.8 cm; size range, 0.7–3.1 cm), including 4 patients with 7 tumors in the liver and 1 patient with 1 tumor in the lung. Technical success was achieved in all patients (5/5, 100%). The complete ablation rate after the first ablation session was 80% (4/5) on a patient-by-patient basis and 87.5% (7/8) on a tumor-by-tumor basis. Only 1 patient developed a fever with temperature >39 °C; it lasted 4 days after radiofrequency ablation (RFA) and was resolved by conservative therapy. During the follow-up period, new intrahepatic recurrences after PAT were detected in two patients. One died due to tumor progression 4 months after ablation. The median overall survival time after PAT was 13.8 months. PAT is a safe and promising therapy for children with recurrent HB after liver resection, and further investigation in large-scale randomized clinical trials is required to determine its role in the treatment of this disease. PMID:26578035
DOE Office of Scientific and Technical Information (OSTI.GOV)
Karuppiah Viswanathan, Ashok Mithra, E-mail: ashokmithrakv@gmail.com; Irodi, Aparna; Keshava, Shyamkumar N., E-mail: aparna-shyam@yahoo.com
2016-09-15
An abnormal fistulous communication between an artery and lymphatic system is a rare occurrence. We report a 38-year-old male presenting with sudden onset, spontaneous, pulsatile swelling in the left supraclavicular region following a recent cardiac catheterisation via right femoral arterial access. On evaluation, he was found to have a femoral arteriolymphatic fistula. He was managed conservatively with ultrasound-guided compression with complete resolution of symptoms at follow-up. This case describes a hitherto unknown complication of percutaneous vascular cannulation presenting in an unusual manner, diagnosed with Doppler Ultrasonography and CT angiography and managed effectively with a non-invasive therapeutic image-guided manoeuvre.
Lanza, Ezio; Banfi, Giuseppe; Serafini, Giovanni; Lacelli, Francesca; Orlandi, Davide; Bandirali, Michele; Sardanelli, Francesco; Sconfienza, Luca Maria
2015-07-01
We performed a systematic review of current evidence regarding ultrasound-guided percutaneous irrigation of calcific tendinopathy (US-PICT) in the shoulder aimed to: assess different published techniques; evaluate clinical outcome in a large combined cohort; and propose suggestions for homogeneous future reporting. Cochrane Collaboration for Systematic Reviews of Interventions Guidelines were followed. We searched MEDLINE/MEDLINE In-Process/EMBASE/Cochrane databases from 1992-2013 using the keywords 'ultrasound, shoulder, needling, calcification, lavage, rotator cuff' combined in appropriate algorithms. References of resulting papers were also screened. Risk of bias was assessed with a modified Newcastle-Ottawa Scale. Of 284 papers found, 15 were included, treating 1,450 shoulders in 1,403 patients (females, n = 838; mean age interval 40-63 years). There was no exclusion due to risk of bias. US-PICT of rotator cuff is a safe and effective procedure, with an estimated average 55% pain improvement at an average of 11 months, with a 10% minor complication rate. No evidence exists in favour of using a specific size/number of needles. Imaging follow-up should not be used routinely. Future studies should aim at structural uniformity, including the use of the Constant Score to assess outcomes and 1-year minimum follow-up. Alternatives to steroid injections should also be explored. • US-PICT of rotator cuff is a safe and effective procedure. • On average 55% pain improvement with 10% minor complication rate. • No evidence exists in favour of using a specific size/number of needles. • Future need to assess outcome using Constant Score with 1-year minimum follow-up.
Abate, Michele; Schiavone, Cosima; Salini, Vincenzo
2015-01-01
To evaluate the efficacy of a specific rehabilitation program for patients in whom ultrasound-guided percutaneous treatment (UGPT) was performed for rotator cuff calcific tendinopathy (RCCT). In this prospective observational study, 86 patients (22 males and 64 females) with shoulder calcific tendinopathy treated with UGPT were enrolled. At the end of the procedure, a corticosteroid injection into the subacromial-subdeltoid bursa was performed. The patients were then asked to follow a specific rehabilitation protocol (2 times/week for 5 weeks) that focused on mobility, strength and function. At baseline and after 6 weeks, clinical parameters, visual analog scale (VAS) and Constant-Murley scale (CMS) scores and ultrasound (US) features were collected. The mean age of the patients was 48.9 ± 8.4 years and their mean BMI was 22.7 ± 2.1. Considering the whole cohort, the treatment was effective, with a significant decrease in the VAS score and an improvement in the CMS score. Thereafter, on the basis of the compliance to the rehabilitation program (by self-report), 53 and 33 patients were included in the rehabilitation group (Rehab group; performed exercises ≥2 times/week) and the No Rehab group (performed exercises <2 times/week), respectively. The comparison between the groups showed that the subjects who performed the exercises regularly had better results in terms of pain and functional recovery, and less associated diseases (e.g. adhesive bursitis and tenosynovitis of the long head of the biceps) than those who were less compliant with the program. UGPT, followed by a specific postprocedure rehabilitation program, was an effective treatment for RCCT. © 2014 S. Karger AG, Basel.
Outcome and safety of transrectal US-guided percutaneous cryotherapy for localized prostate cancer.
Saliken, J C; Donnelly, B J; Brasher, P; Ali-Ridha, N; Ernst, S; Robinson, J
1999-02-01
To assess the effectiveness and safety of ultrasound (US)-guided cryotherapy as a primary treatment for localized prostate cancer. A prospective study of percutaneous transrectal US (TRUS)-guided cryotherapy was performed on 71 patients with T1-T3, N0, M0 prostatic cancer: 10 patients underwent two or more procedures. All cases were newly diagnosed and patients had no previous treatment for cancer. For all patients, TRUS biopsies were performed at 5-6 months. Patients were monitored at 6 weeks; 3, 6, 9, and 12 months; and twice yearly thereafter for prostate specific antigen (PSA) levels, complications, and clinical evidence of residual disease. Follow-up from 10 to 36 months was available for 70 of 71 patients; one patient died of unrelated disease. Initially, 10 of 69 patients had positive postcryotherapy biopsy results. After repeated treatment, nine of these 10 patients had negative biopsy results and one patient had no follow-up. Overall, 68 of 69 patients had negative biopsy results. At 1 year, 43 of 64 (67%) had an undetectable PSA level. Two patients had proven metastases. Complications include three cases with urethral sloughing requiring transurethral resection of the prostate (TURP). One patient had orchitis. Two patients had persistent incontinence, one as the result of a TURP. There was no death, acute serious morbidity, or fistula formation. Impotence was universal at 6 months, but many patients demonstrated late recovery. Cryoablation is an imaging-guided percutaneous intervention for prostate cancer that can safely yield disease-free status in a high percentage of patients with localized disease.
Pure ultrasonography-guided radiation-free percutaneous nephrolithotomy: report of 357 cases.
Hosseini, Mohammad Mehdi; Yousefi, Alireza; Rastegari, Mohsen
2015-01-01
To assess the safety and effectiveness of pure ultrasound-guided percutaneous nephrolithotomy. Three hundred fifty-seven patients were treated; 139 women and 218 men, with a mean age of 33.7 years (range 21-69 years) and a mean stone size of 33.5 mm in maximum diameter (range 20-52 mm). Stone locations were renal pelvis (174), lower calyx (68) or both (115) with mild to moderate hydronephrosis seen on excretory urography. A ureteral stent was inserted by cystoscope, and saline was injected for better localization of the pelvicaliceal system (PCS), if needed. Puncture of the PCS was done by an 18-gauge nephrostomy needle through the lower pole calyx, and all the steps, including dilatation, were done under the guidance of ultrasonography. The day after the operation, 318 (89.07%) patients were stone-free in the kidneys, ureters, and bladder x-rays. Nineteen patients (5.3%) had multiple fragments that measured equal or less than 5 mm and passed them spontaneously in 2-4 weeks (total stone-free rate 94.4%). Access failure occurred in ten obese patients (2.8%) and fluoroscopy was required. Residual fragments with sizes of 10-12 mm were seen in seven patients, all of who underwent shock wave lithotripsy. In one patient, a fragment measuring 7-8 mm migrated into the distal part of the ureter. It was fragmented with ureteroscopy and pneumatic lithoclast 2 days after the operation. In two patients who had large (>15 mm) residual stone redo percutaneous nephrolithotomy was performed 48 h after the first procedure. Percutaneous nephrolithotomy guided by ultrasonography seems to be as effective as fluoroscopy in selected cases and poses no risk of surgeon and patient exposure to radiation; however, more experience is required.
García Bermejo, Paula; De La Cruz Torres, Blanca; Naranjo Orellana, José; Albornoz Cabello, Manuel
2018-01-01
The aim of this study was to establish if the changes in sympathetic and parasympathetic activity (analyzed through heart-rate variability [HRV]) during ultrasound (US)-guided percutaneous needle electrolysis (PNE) is due to the effect of needle puncture only or of the PNE technique per se where the puncture and galvanic current are combined. This was an experimental, case-control study that took place at the University of Seville. Subjects were 36 male footballers who were randomly allocated to three groups: a control group (CG; 12 players), for whom HRV was recorded for 10 min, both at rest and during an exhaustive US examination of the patellar tendon and adjacent structures; a first experimental group (PNE group; 12 players), for whom HRV was recorded for 10 min, both at rest and during application of US-guided PNE in the patellar tendon; and a second experimental group (needle group; 12 players), for whom HRV was recorded for 10 min, both at rest and during application of US-guided PNE without electrical current in the patellar tendon. The outcome measures were the diameters of the Poincaré plot (SD1, SD2), stress score, and sympathetic/parasympathetic ratio. There were no differences between groups in any baseline measurements, nor were there any significant differences between CG measurements (baseline vs. intervention). The PNE group exhibited statistically significant increases in SD1 (p = 0.01) and SD2 (p = 0.004) and statistically significant decreases in SS and S/PS ratio (p = 0.03), indicating increased parasympathetic and decreased sympathetic activity, respectively. The needle group exhibited statistically significant increases in SD2 (p = 0.02) and statistically significant decreases in SS (p = 0.02), indicating decreased sympathetic activity. The application of the US-guided PNE technique caused a measurable increase in parasympathetic activity (detected by HRV), which was due to the combination of needle puncture and electric current.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rivera-Sanfeliz, Gerant, E-mail: gerantrivera@ucsd.edu; Kinney, Thomas B.; Rose, Steven C.
2005-06-15
Purpose: To describe our experience with ultrasound (US)-guided percutaneous liver biopsies using the INRAD 18G Express core needle biopsy system.Methods: One hundred and fifty-four consecutive percutaneous core liver biopsy procedures were performed in 153 men in a single institution over 37 months. The medical charts, pathology reports, and radiology files were retrospectively reviewed. The number of needle passes, type of guidance, change in hematocrit level, and adequacy of specimens for histologic analysis were evaluated.Results: All biopsies were performed for histologic staging of chronic liver diseases. The majority of patients had hepatitis C (134/153, 90.2%). All patients were discharged to homemore » after 4 hr of postprocedural observation. In 145 of 154 (94%) biopsies, a single needle pass was sufficient for diagnosis. US guidance was utilized in all but one of the procedures (153/154, 99.4%). The mean hematocrit decrease was 1.2% (44.1-42.9%). Pain requiring narcotic analgesia, the most frequent complication, occurred in 28 of 154 procedures (18.2%). No major complications occurred. The specimens were diagnostic in 152 of 154 procedures (98.7%).Conclusions: Single-pass percutaneous US-guided liver biopsy with the INRAD 18G Express core needle biopsy system is safe and provides definitive pathologic diagnosis of chronic liver disease. It can be performed on an outpatient basis. Routine post-biopsy monitoring of hematocrit level in stable, asymptomatic patients is probably not warranted.« less
Giménez, Mariano E; Houghton, Eduardo J; Davrieux, C Federico; Serra, Edgardo; Pessaux, Patrick; Palermo, Mariano; Acquafresca, Pablo A; Finger, Caetano; Dallemagne, Bernard; Marescaux, Jacques
2018-03-01
When a major hepatic resection is necessary, sometimes the future liver remnant is not enough to maintain sufficient liver function and patients are more likely to develop liver failure after surgery. To test the hypothesis that performing a percutaneous radiofrecuency liver partition plus percutaneous portal vein embolization (PRALPPS) for stage hepatectomy in pigs is feasible. Four pigs (Sus scrofa domesticus) both sexes with weights between 25 to 35 kg underwent percutaneous portal vein embolization with coils of the left portal vein. By contrasted CT, the difference between the liver parenchyma corresponding to the embolized zone and the normal one was identified. Immediately, using the fusion of images between ultrasound and CT as a guide, radiofrequency needles were placed percutaneouslyand then ablated until the liver partition was complete. Finally, hepatectomy was completed with a laparoscopic approach. All animals have survived the procedures, with no reported complications. The successful portal embolization process was confirmed both by portography and CT. In the macroscopic analysis of the pieces, the depth of the ablation was analyzed. The hepatic hilum was respected. On the other hand, the correct position of the embolization material on the left portal vein could be also observed. "Percutaneous radiofrequency assisted liver partition with portal vein embolization" (PRALLPS) is a feasible procedure.
Carpani, M; Guma, C I; Casal, M A
1982-01-01
The extrinsic compression of the hepatocholedochus by a cavernomatosis of the portal vein, is an unusual pathology. The present case begun clinically as an obstructive jaundice, assuming that the vascular origin of the compression increased the litiasic biliary disease. The percutaneous transhepatic cholangiography was the diagnostic method that suggested a double illness of the biliary system. The surgery and the pathology certificated the diagnosis. The correct treatment once confirmed the obstructive trial, must be: the extraction of the biliary gallstones and the bile-digestive derivation (preferently the hepatic-jejunum anastomosis in Y of Roux).
Evolving biopsy techniques for the diagnosis of neuroblastoma in children.
Campagna, Giovanni; Rosenfeld, Eric; Foster, Jennifer; Vasudevan, Sanjeev; Nuchtern, Jed; Kim, Eugene; Commander, Sarah; Naik-Mathuria, Bindi
2018-04-14
To compare the adequacy and safety of percutaneous core needle biopsy and surgical wedge biopsy of neuroblastoma in children. A retrospective review of patients who underwent biopsy for intermediate- or high-risk neuroblastoma at our institution between 2011 and 2015 was performed (recent cohort). Procedure details and outcomes were collected and analyzed using descriptive statistics and Wilcoxon rank tests; P < 0.05 was considered significant. Published data from 2002 to 2010 were compared (historic cohort). Since 2011, percutaneous, ultrasound-guided, core needle biopsy has been more commonly utilized (47% (16/34) recent vs. 25% (7/28) historic; P = 0.07), and the number of core needle samples increased from median 7 (historic) to 25 (recent). Complications decreased (21% (7/34) recent vs. 64% (18/28) historic; P < 0.01). Biopsy adequacy in the recent cohort was similar (94% percutaneous vs. 89% surgical; P = 1.00), which is improved from the historic cohort (71% percutaneous vs. 100% surgical; P = 0.06). Larger tumors were more likely to have a percutaneous biopsy (82 ± 37 cm percutaneous vs. 47 ± 29 cm surgical; P = 0.04). When multiple cores are obtained, percutaneous core needle biopsy is adequate for complete tissue diagnosis of neuroblastoma and can be safely performed. This can be considered as an alternative to open surgical biopsy. Treatment Study. III. Copyright © 2018 Elsevier Inc. All rights reserved.
Hutson, Nathan; Hung, Joseph C; Puttanniah, Vinay; Lis, Eric; Laufer, Ilya; Gulati, Amitabh
2017-05-01
Tumors invading the sacrum and/or ilium often represent incurable metastatic disease, and treatment is targeted toward palliation of symptoms and control of pain. As systemic opioid therapy is frequently inadequate and limited by side effects, a variety of interventional techniques are available to better optimize analgesia. Using six patients as a paradigm for interventional approaches to pain relief, we present a therapeutic algorithm for treating sacroiliac tumor-related pain in the oncologic population. We describe the use of ultrasound-guided proximal sacroiliac joint corticosteroid injection, sacroiliac lateral branch radiofrequency ablation, percutaneous sacroplasty, and implantable neuraxial drug delivery devices to treat malignant sacroiliac pain in six patients. Pre- and postprocedure numerical rating scale (NRS) pain scores, duration of pain relief, and postprocedure pain medication requirements were studied for each patient. Each patient had marked improvement in their pain based on an average postprocedure NRS difference of six points. The average duration of pain relief was eight months. In all cases, opioid requirements decreased after the intervention. Depending on tumor location, burden of disease, and patient preference, patients suffering from metastatic disease to the sacrum may find benefit from use of ultrasound-guided proximal sacroiliac joint corticosteroid injection, sacroiliac lateral branch radiofrequency ablation, percutaneous sacroplasty, dorsal column stimulator leads, and/or implantable neuraxial drug delivery devices. We provide a paradigm for treatment in this patient population. © 2016 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com
Papini, Enrico; Pacella, Claudio M; Misischi, Irene; Guglielmi, Rinaldo; Bizzarri, Giancarlo; Døssing, Helle; Hegedus, Laszlo
2014-08-01
Surgery is the long-established therapeutic option for benign thyroid nodules, which steadily grow and become symptomatic. The cost of thyroid surgery, the risk of temporary or permanent complications, and the effect on quality of life, however, remain relevant concerns. Therefore, various minimally invasive treatments, directed towards office-based management of symptomatic nodules, without requiring general anaesthesia, and with negligible damage to the skin and cervical tissues, have been proposed during the past two decades. Today, ultrasound-guided percutaneous ethanol injection and thermal ablation with laser or radiofrequency have been thoroughly evaluated, and are accessible procedures in specialized centres. In clinical practice, relapsing thyroid cysts are effectively managed with percutaneous ethanol injection treatment, which should be considered therapy of choice. In solid non-functioning thyroid nodules that grow or become symptomatic, trained operators may safely induce, with a single session of laser ablation treatment or radiofrequency ablation, a 50% volume decrease and, in parallel, improve local symptoms. In contrast, hyperfunctioning nodules remain best treated with radioactive iodine, which results in a better control of hyperthyroidism, also in the long-term, and fewer side-effects. Currently, minimally invasive treatment is also investigated for achieving local control of small size neck recurrences of papillary thyroid carcinoma in patients who are poor candidates for repeat cervical lymph node dissection. This particular use should still be considered experimental. Copyright © 2014 Elsevier Ltd. All rights reserved.
High intensity focused ultrasound (HIFU) in tumor therapy.
Sequeiros, Roberto Blanco; Joronen, Kirsi; Komar, Gaber; Koskinen, Seppo K
HIFU (high intensity focused ultrasound) is a method in which high-frequency ultrasound is focused on a tissue in order to achieve a thermal effect and the subsequent percutaneously ablation, or tissue modulation. HIFU is non-invasive and results in an immediate tissue destruction effect corresponding to surgery, either percutaneously or through body cavities. HIFU can be utilized in the treatment of both benign and malignant tumors. In neurological diseases, focused HIFU can be used in the treatment of disorders of the basal ganglia.
Imaging and radiological interventions in extra-hepatic portal vein obstruction
Pargewar, Sudheer S; Desai, Saloni N; Rajesh, S; Singh, Vaibhav P; Arora, Ankur; Mukund, Amar
2016-01-01
Extrahepatic portal vein obstruction (EHPVO) is a primary vascular condition characterized by chronic long standing blockage and cavernous transformation of portal vein with or without additional involvement of intrahepatic branches, splenic or superior mesenteric vein. Patients generally present in childhood with multiple episodes of variceal bleed and EHPVO is the predominant cause of paediatric portal hypertension (PHT) in developing countries. It is a pre-hepatic type of PHT in which liver functions and morphology are preserved till late. Characteristic imaging findings include multiple parabiliary venous collaterals which form to bypass the obstructed portal vein with resultant changes in biliary tree termed portal biliopathy or portal cavernoma cholangiopathy. Ultrasound with Doppler, computed tomography, magnetic resonance cholangiography and magnetic resonance portovenography are non-invasive techniques which can provide a comprehensive analysis of degree and extent of EHPVO, collaterals and bile duct abnormalities. These can also be used to assess in surgical planning as well screening for shunt patency in post-operative patients. The multitude of changes and complications seen in EHPVO can be addressed by various radiological interventional procedures. The myriad of symptoms arising secondary to vascular, biliary, visceral and neurocognitive changes in EHPVO can be managed by various radiological interventions like transjugular intra-hepatic portosystemic shunt, percutaneous transhepatic biliary drainage, partial splenic embolization, balloon occluded retrograde obliteration of portosystemic shunt (PSS) and revision of PSS. PMID:27358683
Intravascular ultrasound-guided unprotected left main coronary artery stenting in the elderly.
Tan, Qiang; Wang, Qingsheng; Liu, Dongtian; Zhang, Shuangyue; Zhang, Yang; Li, Yang
2015-05-01
To investigate whether intravascular ultrasound (IVUS) guided percutaneous coronary intervention (PCI) could improve clinical outcomes compared with angiography-guided PCI in the treatment of unprotected left main coronary artery stenosis (ULMCA) in the elderly. This controlled study was carried out between October 2009 and September 2012, in Qinhuangdao First Hospital, Hebei Province, China. One hundred and twenty-three consecutive patients with ULMCA, aged 70 or older, were randomized to an IVUS-guided group and a control group. The occurrence of major adverse cardiac events (MACE): death, non-fatal myocardial infarction, or target lesion revascularizations) were recorded after 2 years of follow-up. The IVUS-guided group had a lower rate of 2-year MACE than the control group (13.1% versus 29.3%, p=0.031). The incidence of target lesion revascularization was lower in the IVUS-guided group than in the control group (9.1% versus 24%, p=0.045). However, there were no differences in death and myocardial infarction in the 2 groups. On Cox proportional hazard analysis, distal lesion was the independent predictor of MACE (hazard ratio [HR]: 1.99, confidence interval [CI]: 1.129-2.367; p=0.043); IVUS guidance was independent factor of survival free of MACE (HR: 0.414, CI: 0.129-0.867; p=0.033). The use of IVUS could reduce MACE in elderly patients undergoing ULMCA intervention.
Development of a 3D ultrasound-guided system for thermal ablation of liver tumors
NASA Astrophysics Data System (ADS)
Neshat, Hamid R. S.; Cool, Derek W.; Barker, Kevin; Gardi, Lori; Kakani, Nirmal; Fenster, Aaron
2013-03-01
Two-dimensional ultrasound (2D US) imaging is commonly used for diagnostic and intraoperative guidance of interventional abdominal procedures including percutaneous thermal ablation of focal liver tumors with radiofrequency (RF) or microwave (MW) induced energy. However, in many situations 2D US may not provide enough anatomical detail and guidance information. Therefore, intra-procedural CT or MR imaging are used in many centers for guidance purposes. These modalities are costly and are mainly utilized to confirm tool placement rather than guiding the insertion. Three-dimensional ultrasound (3D US) has been introduced to address these issues. In this paper, we present our integrated solution to provide 3D US images using a newly developed mechanical transducer with a large field-ofview and without the need for external tracking devices to combine diagnostic and planning information of different modalities for intraoperative guidance. The system provides tools to segment the target(s), plan the treatment, and detect the ablation applicators during the procedure for guiding purposes. We present experimental results used to ensure that our system generates accurate measurements and our early clinical evaluation results. The results suggest that 3D US used for focal liver ablation can provide a more reliable planning and guidance tool compared to 2D US only, and in many cases offers comparable measurements to other alternatives at significantly lower cost, faster time and with no harmful radiation.
Mauri, Giovanni; Sconfienza, Luca Maria; Pescatori, Lorenzo Carlo; Fedeli, Maria Paola; Alì, Marco; Di Leo, Giovanni; Sardanelli, Francesco
2017-08-01
To systematically review studies concerning imaging-guided minimally-invasive breast cancer treatments. An online database search was performed for English-language articles evaluating percutaneous breast cancer ablation. Pooled data and 95% confidence intervals (CIs) were calculated. Technical success, technique efficacy, minor and major complications were analysed, including ablation technique subgroup analysis and effect of tumour size on outcome. Forty-five studies were analysed, including 1,156 patients and 1,168 lesions. Radiofrequency (n=577; 50%), microwaves (n=78; 7%), laser (n=227; 19%), cryoablation (n=156; 13%) and high-intensity focused ultrasound (HIFU, n=129; 11%) were used. Pooled technical success was 96% (95%CI 94-97%) [laser=98% (95-99%); HIFU=96% (90-98%); radiofrequency=96% (93-97%); cryoablation=95% (90-98%); microwave=93% (81-98%)]. Pooled technique efficacy was 75% (67-81%) [radiofrequency=82% (74-88); cryoablation=75% (51-90); laser=59% (35-79); HIFU=49% (26-74)]. Major complications pooled rate was 6% (4-8). Minor complications pooled rate was 8% (5-13%). Differences between techniques were not significant for technical success (p=0.449), major complications (p=0.181) or minor complications (p=0.762), but significant for technique efficacy (p=0.009). Tumour size did not impact on variables (p>0.142). Imaging-guided percutaneous ablation techniques of breast cancer have a high rate of technical success, while technique efficacy remains suboptimal. Complication rates are relatively low. • Imaging-guided ablation techniques for breast cancer are 96% technically successful. • Overall technique efficacy rate is 75% but largely inhomogeneous among studies. • Overall major and minor complication rates are low (6-8%).
Malignant biliary disease: percutaneous interventions.
Morgan, R A; Adam, A N
2001-09-01
Interventional radiologists have an important role in the management of patients with malignant biliary obstruction. This article describes the techniques for percutaneous biliary drainage, insertion of biliary endoprostheses, and the management of occluded biliary endoprostheses. Most procedures are performed by using fluoroscopic guidance alone. Ultrasound is also a useful modality for guiding biliary drainage, particularly drainage of the left biliary ducts. Patients should be treated by internal drainage if possible. Metallic endoprostheses can be inserted at the time of the initial biliary drainage procedure. Plastic tubes should be inserted a few days after biliary drainage because of their relatively large size compared with metallic stents. Occluded plastic stents should be replaced. Blocked metallic stents should be treated either by placement of additional overlapping metallic stents or by placement of plastic stents within the metallic stent lumen. Copyright 2001 by W.B. Saunders Company
NASA Astrophysics Data System (ADS)
Sadeghi Neshat, Hamid; Bax, Jeffery; Barker, Kevin; Gardi, Lori; Chedalavada, Jason; Kakani, Nirmal; Fenster, Aaron
2014-03-01
Image-guided percutaneous ablation is the standard treatment for focal liver tumors deemed inoperable and is commonly used to maintain eligibility for patients on transplant waitlists. Radiofrequency (RFA), microwave (MWA) and cryoablation technologies are all delivered via one or a number of needle-shaped probes inserted directly into the tumor. Planning is mostly based on contrast CT/MRI. While intra-procedural CT is commonly used to confirm the intended probe placement, 2D ultrasound (US) remains the main, and in some centers the only imaging modality used for needle guidance. Corresponding intraoperative 2D US with planning and other intra-procedural imaging modalities is essential for accurate needle placement. However, identification of matching features of interest among these images is often challenging given the limited field-of-view (FOV) and low quality of 2D US images. We have developed a passive tracking arm with a motorized scan-head and software tools to improve guiding capabilities of conventional US by large FOV 3D US scans that provides more anatomical landmarks that can facilitate registration of US with both planning and intra-procedural images. The tracker arm is used to scan the whole liver with a high geometrical accuracy that facilitates multi-modality landmark based image registration. Software tools are provided to assist with the segmentation of the ablation probes and tumors, find the 2D view that best shows the probe(s) from a 3D US image, and to identify the corresponding image from planning CT scans. In this paper, evaluation results from laboratory testing and a phase 1 clinical trial for planning and guiding RFA and MWA procedures using the developed system will be presented. Early clinical results show a comparable performance to intra-procedural CT that suggests 3D US as a cost-effective alternative with no side-effects in centers where CT is not available.
Valera-Garrido, Fermín; Minaya-Muñoz, Francisco; Medina-Mirapeix, Francesc
2014-12-01
Ultrasound (US)-guided percutaneous needle electrolysis (PNE) is a novel minimally invasive approach which consists of the application of a galvanic current through an acupuncture needle. To evaluate the clinical and ultrasonographic effectiveness of a multimodal programme (PNE, eccentric exercise (EccEx) and stretching) in the short term for patients with chronic lateral epicondylitis, and to determine whether the clinical outcomes achieved decline over time. A one-way repeated measures study was performed in a clinical setting in 36 patients presenting with lateral epicondylitis. The patients received one session of US-guided PNE per week over 4-6 weeks, associated with a home programme of EccEx and stretching. The main outcome measures were severity of pain, disability (Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire), structural tendon changes (US), hypervascularity and patients' perceptions of overall outcome. Measurements at 6, 26 and 52 weeks follow-up included recurrence rates (increase in severity of pain or disability compared with discharge), perception of overall outcome and success rates. All outcome measures registered significant improvements between pre-intervention and discharge. Most patients (n=30, 83.3%) rated the overall outcome as 'successful' at 6 weeks. The ultrasonographic findings showed that the hypoechoic regions and hypervascularity of the extensor carpi radialis brevis changed significantly. At 26 and 52 weeks, all participants (n=32) perceived a 'successful' outcome. Recurrence rates were null after discharge and at follow-up at 6, 26 and 52 weeks. Symptoms and degenerative structural changes of chronic lateral epicondylitis are reduced after US-guided PNE associated with EccEx and stretching, with encouragingly low recurrences in the mid to long term. ClinicalTrials.gov identifier: NCT02085928. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Kopac, Daniel S; Chen, Jerry; Tang, Raymond; Sawka, Andrew; Vaghadia, Himat
2013-09-01
Ultrasound-guided percutaneous vascular access for endovascular procedures is well established in surgical practice. Despite this, rates of complications from venous and arterial access procedures remain a significant cause of morbidity. We hypothesized that the use of a new technique of vascular access using an ultrasound with a novel needle-guidance positioning system (GPS) would lead to improved success rates of vascular puncture for both in-plane and out-of-plane techniques compared with traditional ultrasound. A prospective, randomized crossover study of medical students from all years of medical school was conducted using a phantom gel model. Each medical student performed three ultrasound-guided punctures with each of the four modalities (in-plane no GPS, in-plane with GPS, out-of-plane no GPS, out-of-plane with GPS) for a total of 12 attempts. The success or failure was judged by the ability to aspirate a simulated blood solution from the model. The time to successful puncture was also recorded. A poststudy validated NASA Task Load Index workload questionnaire was conducted to assess the student's perceptions of the two different techniques. A total of 30 students completed the study. There was no significant difference seen in the mean times of vascular access for each of the modalities. Higher success rates for vascular access using the GPS for both the in-plane (94% vs 91%) and the out-of-plane (86% vs 70%) views were observed; however, this was not statistically significant. The students perceived the mental demand (median 12.0 vs 14.00; P = .035) and effort to be lower (mean 11.25 vs 14.00; P = .044) as well as the performance to be higher (mean 15.50 vs 14.00; P = .041) for the GPS vs the traditional ultrasound-guided technique. Students also perceived their ability to access vessels increased with the aid of the GPS (7.00 vs 6.50; P = .007). The majority of students expressed a preference for GPS (26/30, 87%) as opposed to the traditional counterpart. Use of the novel SonixGPS needle-tracking ultrasound system (UltraSonix, Richmond, BC, Canada) was not associated with a higher success rate of vascular puncture compared with the traditional ultrasound-guided technique. Assessment of mental task load significantly favored the use of the ultrasound GPS over the traditional ultrasound technique. Copyright © 2013 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carrafiello, Gianpaolo, E-mail: gcarraf@tin.it; Lagana, Domenico; Cotta, Elisa
The purpose of this study was to evaluate the safety and efficacy of percutaneous ultrasound (US)-guided radiofrequency ablation (RFA) in patients with intrahepatic cholangiocarcinoma (ICCA) in a small, nonrandomized series. From February 2004 to July 2008, six patients (four men and two women; mean age 69.8 years [range 48 to 83]) with ICCA underwent percutaneous US-guided RFA. Preintervetional transarterial embolization was performed in two cases to decrease heat dispersion during RFA in order to increase the area of ablation. The efficacy of RFA was evaluated using contrast-enhanced dynamic computed tomography (CT) 1 month after treatment and then every 3 monthsmore » thereafter. Nine RFA sessions were performed for six solid hepatic tumors in six patients. The duration of follow-up ranged from 13 to 21 months (mean 17.5). Posttreatment CT showed total necrosis in four of six tumors after one or two RFA sessions. Residual tumor was observed in two patients with larger tumors (5 and 5.8 cm in diameter). All patients tolerated the procedure, and there with no major complications. Only 1 patient developed post-RFA syndrome (pain, fever, malaise, and leukocytosis), which resolved with oral administration of acetaminophen. Percutaneous RFA is a safe and effective treatment for patients with hepatic tumors: It is ideally suited for those who are not eligible for surgery. Long-term follow-up data regarding local and systemic recurrence and survival are still needed.« less
Duplex-guided percutaneous transluminal angioplasty in iliac arterial occlusive disease.
Krasznai, A G; Sigterman, T A; Welten, R J; Heijboer, R; Sikkink, C J J M; van de Akker, L H J M; Bouwman, L H
2013-11-01
Chronic renal insufficiency (CRI) is a growing global problem. PTA can be performed without nephrotoxic contrast, utilizing Doppler-ultrasound (Duplex) guidance. Duplex-guided infra-inguinal interventions and access-related interventions have been reported. Duplex-guided iliac interventions have not been performed to any extent because of the anatomic location. In our study we evaluated the safety and efficacy of Duplex-guided percutaneous transluminal angioplasty (DuPTA) in iliac arteries. From June 2012 until February 2013, 31 patients (35 iliac lesions), underwent DuPTA. Indications ranged from Rutherford 3 to 5. Preoperative evaluation included Ankle Brachial Index (ABI), Duplex and MRA. Procedural success was defined as crossing the lesion with a guidewire and dilating or stenting the lesion. Clinical success was defined as 50% reduction in peak systolic velocity (PSV) or clinical improvement. PSV was evaluated after PTA, then at 2 weeks. Clinical results were assessed 2 weeks after the procedure. Procedural success was achieved in 94% of patients (33/35), all of whom also had clinical success. Post-procedural PSV reduction showed an average improvement of 63% (431 cm/s to 153 cm/s). Mean preoperative ABI was 0.72 and improved to 0.88 postoperatively. PTA using Duplex-guidance in significant iliac stenosis is a safe method with major advantages in patients at high risk for developing contrast-induced nephropathy. Copyright © 2013 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.
Zhang, Ji-Qing; Wang, Yong; Zhang, Jun-Hui; Zhang, Xiao-Dong; Xing, Nian-Zeng
2016-09-05
Percutaneous nephrolithotomy (PCNL) is the most widely recommended treatment for calyceal diverticular calculi, providing excellent stone-free results. However, its invasiveness is not negligible considering its major complication rates. Flexible ureteroscopy (FURS) is currently used to treat calyceal diverticula. However, the greatest drawback of FURS is locating the diverticulum since its neck is narrow and concealed. In such a case, the FURS procedure must be converted to PCNL. The aim of this study was to evaluate ultrasound-guided flexible ureteroscopy (UFURS) identifying diverticulum and the management of calyceal diverticular calculi. A retrospective analysis was conducted on 24 patients who had calyceal diverticular calculi. In all 12 patients in the UFURS group, direct FURS failed to find evidence of calyceal diverticula but were confirmed with imaging. The other 12 patients in the PCNL group received PCNL plus fulguration of the diverticular walls. Puncture of calyceal diverticulum was successful in all 12 UFURS patients. Two patients in this group had postoperative residual calculi and two patients developed fever. In the PCNL group, percutaneous renal access and lithotomy were successful in all 12 patients. One patient in this group had residual calculi, one had perirenal hematoma, and two patients developed fever. No significant difference was found in the operating time (UFURS vs. PCNL, 91.8 ± 24.2 vs. 86.3 ± 18.7 min), stone-free rate (UFURS vs. PCNL, 9/12 vs. 10/12), and rate of successful lithotripsy (UFURS vs. PCNL, 10/12 vs. 11/12) between the two groups (all P> 0.05). Postoperative pain scores in the FURS group were significantly lower than that in the PCNL group (2.7 ± 1.2 vs. 6.2 ± 1.5, P< 0.05). Hospital stay in the UFURS group was significantly shorter than that in the PCNL group (3.4 ± 0.8 vs. 5.4 ± 1.0 days, P< 0.05). All patients were symptom-free following surgery (UFURS vs. PCNL, 10/10 vs. 12/12). Ultrasound-guided puncture facilitates identification of calyceal diverticula during FURS and improves the success rate of FURS surgery.
Mancini, Andrea; Castriotta, Giuseppe; Angelini, Pernina; Bozzi, Michele; Giancaspro, Vincenzo; La Raia, Elvira; Nisi, Maria Teresa; Proscia, Anna Rita; Tarantino, Giuseppe; Vitale, Ottavia; Cuzzola, Cristoforo
2017-06-01
A pseudoaneurysm or false aneurysm of the brachial artery is an uncommon occurrence in patients receiving hemodialysis with arteriovenous fistula (AVF). We describe the case of a 76-year-old woman presenting with a large, tender, pulsatile mass in the right antecubital region 10 cm from the AVF. B-mode ultrasound examination revealed a saccular hematoma. Color doppler showed a recirculation movement of blood, creating a two colors image called "Korean flag". The patient was transferred to the surgical unit where she first underwent ultrasound-guided compression and then surgical repair of the pseudoaneurysm. Two weeks after surgery the AVF was used again as an access for hemodialysis. Differentiating between a false and a true aneurysm based on ultrasound is not always straightforward. Doppler ultrasound findings can be decisive for the early diagnosis of a pseudoaneurysm to ensure proper treatment planning given the dangerous complications of ruptures. Treatment options include: compression, percutaneous thrombin injection, endovascular exclusion with covered stents, aneurysmectomy and surgical repair. Copyright by Società Italiana di Nefrologia SIN, Rome, Italy.
Liu, Jie; Zhang, Chengwu; Hong, Defei; Shang, Minjie; Yao, Weifeng; Chen, Yuan
2017-01-01
Abstract Rationale: The liver is the most frequent site of relapse of gastrointestinal stromal tumors (GISTs). Surgery is always considered to be unsuitable because of the multiple metastases. Patient concerns: In this report, we describe a case of large, multiple GIST liver metastases that were treated with percutaneous microwave ablation liver partition and portal vein embolization for planned hepatectomy (PALPP). A 44-year-old woman had undergone pancreaticoduodenectomy 4 years previously because of the diagnosis of a large duodenal GIST. Large, multiple liver metastases were observed 2 years later. Diagnoses: GIST liver metastasis was diagnosed using percutaneous ultrasound-guided biopsy. Interventions: After 6 months of treatment with imatinib, the liver metastasis was stable. PALPP was performed because of insufficient future liver remnant (FLR) and right trisegmentectomy was successfully completed 10 days later. Outcomes: The patient has had no signs of local or systemic disease during 17 months of postsurgical follow-up. Lessons: PALPP provides a new methodology for treatment of GIST liver metastasis in patients with insufficient FLR, and may have benefit in prolonging a durable remission. PMID:29049221
Nagata, Jun; Watanabe, Jun; Sawatsubashi, Yusuke; Akiyama, Masaki; Arase, Koichi; Minagawa, Noritaka; Torigoe, Takayuki; Hamada, Kotaro; Nakayama, Yoshifumi; Hirata, Keiji
2017-04-04
Although the laparoscopic approach reduces pain associated with abdominal surgery, postoperative pain remains a problem. Ultrasound-guided rectus sheath block and transversus abdominis plane block have become increasingly popular means of providing analgesia for laparoscopic surgery. Ninety patients were enrolled in this study. A laparoscopic puncture needle was inserted via the port, and levobupivacaine was injected into the correct plane through the peritoneum. The patients' postoperative pain intensity was assessed using a numeric rating scale. The effects of laparoscopic nerve block versus percutaneous anesthesia were compared. This novel form of transperitoneal anesthesia did not jeopardize completion of the operative procedures. The percutaneous approach required more time for performance of the procedure than the transperitoneal technique. This new analgesia technique can become an optional postoperative treatment regimen for various laparoscopic abdominal surgeries. What we mainly want to suggest is that the transperitoneal approach has the advantage of a higher completion rate. A percutaneous technique is sometimes difficult with patients who have severe obesity and/or coagulation disorders. Additional studies are required to evaluate its benefits. Copyright © 2017. Published by Elsevier Taiwan.
Pillai, Anil Kumar; Silvers, William; Christensen, Preston; Riegel, Matthew; Adams-Huet, Beverley; Lingvay, Ildiko; Sun, Xiankai; Öz, Orhan K
2015-01-01
Advances in noninvasive imaging modalities have provided opportunities to study β cell function through imaging zinc release from insulin secreting β cells. Understanding the temporal secretory pattern of insulin and zinc corelease after a glucose challenge is essential for proper timing of administration of zinc sensing probes. Portal venous sampling is an essential part of pharmacological and nutritional studies in animal models. The purpose of this study was to compare two different percutaneous image-guided techniques: transhepatic ultrasound guided portal vein access and transsplenic fluoroscopy guided splenic vein access for ease of access, safety, and evaluation of temporal kinetics of insulin and zinc release into the venous effluent from the pancreas. Both techniques were safe, reproducible, and easy to perform. The mean time required to obtain desired catheter position for venous sampling was 15 minutes shorter using the transsplenic technique. A clear biphasic insulin release profile was observed in both techniques. Statistically higher insulin concentration but similar zinc release after a glucose challenge was observed from splenic vein samples, as compared to the ones from the portal vein. To our knowledge, this is the first report of percutaneous methods to assess zinc release kinetics from the porcine pancreas.
Pillai, Anil Kumar; Silvers, William; Christensen, Preston; Riegel, Matthew; Adams-Huet, Beverley; Lingvay, Ildiko; Sun, Xiankai; Öz, Orhan K.
2015-01-01
Advances in noninvasive imaging modalities have provided opportunities to study β cell function through imaging zinc release from insulin secreting β cells. Understanding the temporal secretory pattern of insulin and zinc corelease after a glucose challenge is essential for proper timing of administration of zinc sensing probes. Portal venous sampling is an essential part of pharmacological and nutritional studies in animal models. The purpose of this study was to compare two different percutaneous image-guided techniques: transhepatic ultrasound guided portal vein access and transsplenic fluoroscopy guided splenic vein access for ease of access, safety, and evaluation of temporal kinetics of insulin and zinc release into the venous effluent from the pancreas. Both techniques were safe, reproducible, and easy to perform. The mean time required to obtain desired catheter position for venous sampling was 15 minutes shorter using the transsplenic technique. A clear biphasic insulin release profile was observed in both techniques. Statistically higher insulin concentration but similar zinc release after a glucose challenge was observed from splenic vein samples, as compared to the ones from the portal vein. To our knowledge, this is the first report of percutaneous methods to assess zinc release kinetics from the porcine pancreas. PMID:26273676
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hakime, Antoine, E-mail: thakime@yahoo.com; Yevich, Steven; Tselikas, Lambros
PurposeTo assess whether fusion imaging-guided percutaneous microwave ablation (MWA) can improve visibility and targeting of liver metastasis that were deemed inconspicuous on ultrasound (US).Materials and MethodsMWA of liver metastasis not judged conspicuous enough on US was performed under CT/US fusion imaging guidance. The conspicuity before and after the fusion imaging was graded on a five-point scale, and significance was assessed by Wilcoxon test. Technical success, procedure time, and procedure-related complications were evaluated.ResultsA total of 35 patients with 40 liver metastases (mean size 1.3 ± 0.4 cm) were enrolled. Image fusion improved conspicuity sufficiently to allow fusion-targeted MWA in 33 patients. The time requiredmore » for image fusion processing and tumors’ identification averaged 10 ± 2.1 min (range 5–14). Initial conspicuity on US by inclusion criteria was 1.2 ± 0.4 (range 0–2), while conspicuity after localization on fusion imaging was 3.5 ± 1 (range 1–5, p < 0.001). Technical success rate was 83% (33/40) in intention-to-treat analysis and 100% in analysis of treated tumors. There were no major procedure-related complications.ConclusionsFusion imaging broadens the scope of US-guided MWA to metastasis lacking adequate conspicuity on conventional US. Fusion imaging is an effective tool to increase the conspicuity of liver metastases that were initially deemed non visualizable on conventional US imaging.« less
Intravascular Ultrasound to Guide Percutaneous Coronary Interventions
2006-01-01
Executive Summary Objective The objective of this health technology policy assessment was to determine the effectiveness and cost-effectiveness of using intravascular ultrasound (IVUS) as an adjunctive imaging tool to coronary angiography for guiding percutaneous coronary interventions. Background Intravascular Ultrasound Intravascular ultrasound is a procedure that uses high frequency sound waves to acquire 3-dimensional images from the lumen of a blood vessel. The equipment for performing IVUS consists of a percutaneous transducer catheter and a console for reconstructing images. IVUS has been used to study the structure of the arterial wall and nature of atherosclerotic plaques, and obtain measurements of the vessel lumen. Its role in guiding stent placement is also being investigated. IVUS is presently not an insured health service in Ontario. Clinical Need Coronary artery disease accounts for approximately 55% of cardiovascular deaths, the leading cause of death in Canada. In Ontario, the annual mortality rate due to ischemic heart disease was 141.8 per 100,000 population between 1995 and 1997. Percutaneous coronary intervention (PCI), a less invasive approach to treating coronary artery disease, is used more frequently than coronary bypass surgery in Ontario. The number of percutaneous coronary intervention procedures funded by the Ontario Ministry of Health and Long-term Care is expected to increase from approximately 17, 780 in 2004/2005 to 22,355 in 2006/2007 (an increase of 26%), with about 95% requiring the placement of one or more stents. Restenosis following percutaneous coronary interventions involving bare metal stents occurs in 15% to 30% of the cases, mainly because of smooth muscle proliferation and migration, and production of extracellular matrix. In-stent restenosis has been linked to suboptimal stent expansion and inadequate lesion coverage, while stent thrombosis has been attributed to incomplete stent-to-vessel wall apposition. Since coronary angiography (the imaging tool used to guide stent placement) has been shown to be inaccurate in assessing optimal stent placement, and IVUS can provide better views of the vessel lumen, the clinical utility of IVUS as an imaging tool adjunctive to coronary angiography in coronary intervention procedures has been explored in clinical studies. Method A systematic review was conducted to answer the following questions: What are the procedure-related complications associated with IVUS? Does IVUS used in conjunction with angiography to guide percutaneous interventions improve patient outcomes compared to angiographic guidance without IVUS? Who would benefit most in terms of clinical outcomes from the use of IVUS adjunctive to coronary angiography in guiding PCIs? What is the effectiveness of IVUS guidance in the context of drug-eluting stents? What is the cost-effectiveness ratio and budget impact of adjunctive IVUS in PCIs in Ontario? A systematic search of databases OVID MEDLINE, EMBASE, MEDLINE In-Process & Other Non-Indexed Citations, The Cochrane Library, and the International Agency for Health Technology Assessment (INAHTA) database for the period beginning in May 2001 until the day of the search, November 4, 2005 yielded 2 systematic reviews, 1 meta-analysis, 6 randomized controlled trials, and 2 non-randomized studies on left main coronary arteries. The quality of the studies ranged from moderate to high. These reports were combined with reports from a previous systematic review for analysis. In addition to qualitative synthesis, pooled analyses of data from randomized controlled studies using a random effect model in the Cochrane Review Manager 4.2 software were conducted when possible. Findings of Literature Review & Analysis Safety Intravascular ultrasound appears to be a safe tool when used in coronary interventions. Periprocedural complications associated with the use of IVUS in coronary interventions ranged from 0.5% in the largest study to 4%. Coronary rupture was reported in 1 study (1/54). Other complications included prolonged spasms of the artery after stenting, dissection, and femoral aneurysm. Effectiveness Based on pooled analyses of data from randomized controlled studies, the use of intravascular ultrasound adjunctive to coronary intervention in percutaneous coronary interventions using bare metal stents yielded the following findings: For lesions predominantly at low risk of restenosis: There were no significant differences in preintervention angiographic minimal lumen diameter between the IVUS-guided and angiography-guided groups. IVUS guidance resulted in a significantly larger mean postintervention angiographic minimal lumen diameter (weighted mean difference of 0.11 mm, P = .0003) compared to angiographic guidance alone. The benefit in angiographic minimal lumen diameter from IVUS guidance was not maintained at 6-month follow-up, when no significant difference in angiographic minimal lumen diameter could be detected between the two arms (weighted mean difference 0.08, P = .13). There were no statistically significant differences in angiographic binary restenosis rates between IVUS-guidance and no IVUS guidance (Odds ratio [OR] 0.87 in favour of IVUS, 95% Confidence Interval [CI] [0.64–1.18], P = 0.37). IVUS guidance resulted in a reduction in the odds of target lesion revascularization (repeat percutaneous coronary intervention or coronary bypass graft) compared to angiographic guidance alone. The reduction was statistically significant at a follow-up period of 6 months to 1 year, and at a follow-up period of 18 month to 2 years (OR 0.52 in favour of IVUS, 95% CI [0.33–0.81], P = .004). Total revascularization rate (either target lesion or target vessel revascularization) was significantly lower for IVUS-guided patients at 18 months to 2.5 years after intervention (OR 0.43 in favour of IVUS, 95% CI [0.29–0.63], p < .0001). There were no statistically significant differences in the odds of death (OR 1.36 in favour of no IVUS, P =0.65) or myocardial infarction (OR 0.95 in favour of IVUS, P = 0.93) between IVUS-guidance and angiographic guidance alone at up to 2.5 years of follow-up The odds of having a major cardiac event (defined as death, myocardial infarction, and target lesion or target vessel revascularization) were significantly lower for patients with IVUS guidance compared to angiographic guidance alone during follow-up periods of up to 2.5 years (OR 0.53, 95% CI [0.36–0.78], P = 0.001). Since there were no significant reductions in the odds of death or myocardial infarction, the reduction in the odds of combined events reflected mainly the reduction in revascularization rates. For lesions at High Risk of Restenosis: There is evidence from one small, randomized controlled trial (n=150) that IVUS-guided percutaneous coronary intervention in long de novo lesions (>20 mm) of native coronary arteries resulted in statistically significant larger minimal lumen Diameter, and statistically significant lower 6-month angiographic binary restenosis rate. Target vessel revascularization rate and the rate of combined events were also significantly reduced at 12 months. A small subgroup analysis of a randomized controlled trial reported no benefit in clinical or angiographic outcomes for IVUS-guided percutaneous coronary interventions in patients with diabetes compared to those guided by angiography. However, due to the nature and size of the analysis, no firm conclusions could be reached. Based on 2 small, prospective, non-randomized controlled studies, IVUS guidance in percutaneous coronary interventions of left main coronary lesions using bare metal stents or drug-eluting stents did not result in any benefits in angiographic or clinical outcomes. These findings need to be confirmed. Interventions Using Drug-Eluting Stents There is presently no evidence on whether the addition of IVUS guidance during the implantation of drug-eluting stents would reduce incomplete stent apposition, or improve the angiographic or clinical outcomes of patients. Ontario-Based Economic Analysis Cost-effectiveness analysis showed that PCIs using IVUS guidance would likely be less costly and more effective than PCIs without IVUS guidance. The upfront cost of adjunctive use of IVUS in PCIs ranged from $1.56 million at 6% uptake to $13.04 million at 50% uptake. Taking into consideration cost avoidance from reduction in revascularization associated with the use of IVUS, a net saving of $0.63 million to $5.2 million is expected. However, since it is uncertain whether the reduction in revascularization rate resulting from the use of IVUS can be generalized to clinical settings in Ontario, further analysis on the budget impact and cost-effectiveness need to be conducted once Ontario-specific revascularization rates are verified. Factors to be Considered in the Ontario Context Applicability of Findings to Ontario The interim analysis of an Ontario field evaluation that compared drug-eluting stents to bare metal stents showed that the revascularization rates in low-risk patients with bare metal stents were much lower in Ontario compared to rates reported in randomized controlled trials (7.2% vs >17 %). Even though IVUS is presently not routinely used in the stenting of low-risk patients in Ontario, the revascularization rates in these patients in Ontario were shown to be lower than those reported for the IVUS groups reported in published studies. Based on this information and previous findings from the Ontario field evaluation on stenting, it is uncertain whether the reduction in revascularization rates from IVUS guidance can be generalized to Ontario. In light of the above findings, it is advisable to validate the reported benefits of IVUS guidance in percutaneous coronary interventions involving bare metal stents in the Ontario context. Licensing Status As of January 16, 2006, Health Canada has licensed 10 intravascular ultrasound imaging systems/catheters for transluminal intervention procedures, most as class 4 medical devices. Current Funding IVUS is presently not an insured procedure under the Ontario Health Insurance Plan and there are no professional fees for this procedure. All costs related to the use of IVUS are covered within hospitals’ global budgets. A single use IVUS catheter costs approximately $900CDN and the procedure adds approximately 20 minutes to 30 minutes to a percutaneous coronary intervention procedure. Diffusion According to an expert consultant, current use of IVUS in coronary interventions in Ontario is probably limited to high-risk cases such as interventions in long lesions, small vessels, and bifurcated lesions for which images from coronary angiography are indeterminate. It was estimated that IVUS is being used in about 6% of all percutaneous coronary interventions at a large Ontario cardiac centre. Expert Opinion IVUS greatly enhances the cardiac interventionists’ ability to visualize and assess high-risk lesions such as long lesions, narrow lesions, and bifurcated lesions that may have indeterminate angiographic images. Information from IVUS in these cases facilitates the choice of the most appropriate approach for the intervention. Conclusion The use of adjunctive IVUS in PCIs using bare metal stents in lesions predominantly at low risk for restenosis had no significant impact on survival, myocardial infarction, or angiographic restenosis rates up to 2.5 years after intervention. The use of IVUS adjunctive to coronary angiography in percutaneous coronary interventions using bare metal stents in lesions predominantly at low risk for restenosis significantly reduced the target lesion and target vessel revascularization at a follow-up period of 18 months to 2.5 years. One small study suggests that adjunctive IVUS in PCIs using bare metal stents in long lesions (>20 mm) significantly improved the 6-month angiographic restenosis rate and one-year target lesion revascularization rate. These results need to be confirmed with large randomized controlled trials. Based on information from the Ontario field evaluation on stenting, it is uncertain whether the reduction in revascularization rate resulting from the use of IVUS in the placement of bare metal stents can be generalized to clinical settings in Ontario. There is presently insufficient evidence available to determine the impact of adjunctive IVUS in percutaneous interventions in high-risk lesions (other than long lesions) or in PCIs using drug-eluting stents. PMID:23074482
McCord, Kelly; Steyn, Philip F; Lunn, Katharine F
2008-07-01
A 12-year-old, 6 kg, castrated male Siamese-cross cat was referred for investigation of an abdominal mass. The cat was found to have a left perinephric pseudocyst (PNP), accompanied by azotemia, with a small right kidney detected on ultrasound. Glomerular filtration rate (GFR) was determined by renal scintigraphy and was found to be low, with the left kidney contributing 64% of the total GFR. Percutaneous ultrasound-guided drainage of the PNP did not improve the GFR, and fluid reaccumulated within a short period of time. Laparoscopic fenestration of the cyst capsule was performed to allow for permanent drainage. The PNP did not recur, renal values progressively improved, and 8 months after the capsulotomy the GFR of the left kidney had increased by 50%, while renal function remained static on the right side.
Carrizo, Sebastián; Xie, Xinzhou; Peinado-Peinado, Rafael; Sánchez-Recalde, Angel; Jiménez-Valero, Santiago; Galeote-Garcia, Guillermo; Moreno, Raúl
2014-10-01
Clinical trials have shown that functional assessment of coronary stenosis by fractional flow reserve (FFR) improves clinical outcomes. Intravascular ultrasound (IVUS) complements conventional angiography, and is a powerful tool to assess atherosclerotic plaques and to guide percutaneous coronary intervention (PCI). Computational fluid dynamics (CFD) simulation represents a novel method for the functional assessment of coronary flow. A CFD simulation can be calculated from the data normally acquired by IVUS images. A case of coronary heart disease studied with FFR and IVUS, before and after PCI, is presented. A three-dimensional model was constructed based on IVUS images, to which CFD was applied. A discussion of the literature concerning the clinical utility of CFD simulation is provided. Copyright © 2014 Sociedade Portuguesa de Cardiologia. Published by Elsevier España. All rights reserved.
An alternative and inexpensive percutaneous access needle in pediatric patients.
Penbegul, Necmettin; Soylemez, Haluk; Bozkurt, Yasar; Sancaktutar, Ahmet Ali; Bodakci, Mehmet Nuri; Hatipoglu, Namik Kemal; Atar, Murat; Yildirim, Kadir
2012-10-01
The most important factor that increases the cost of percutaneous surgery is the disposable instruments used for the surgery. In this study we present the advantages of using an intravenous cannula instead of a percutaneous access needle for renal access. Recently, percutaneous stone surgery has grown in use in pediatric cases and is considered a minimally invasive surgery. The most important step in this surgery is access to the renal collecting systems. Although fluoroscopy has been used frequently at this stage, the use of ultrasound has recently increased. During percutaneous accesses under all types of imaging techniques, disposable 11- to 15-cm-long 18-ga needles are used. In pediatric cases, these longer needles are difficult to use. Using disposable materials in percutaneous nephrolithotomy increases the cost of the procedure. Therefore, we asserted that percutaneous access especially in pediatric cases could be performed using a 16-ga intravenous cannula (angiocath). Indeed, percutaneous access was performed successfully, especially in pediatric preschool patients. Shorter needle length, easy skin entry, comfort of manipulation, clear visualization of the metal needle on ultrasound, and wide availability can be considered advantages of this method. The angiocath is also less expensive than a percutaneous access needle. Angiocath is inexpensive, easily available, and practical, and it is the shortest needle to perform percutaneous access in pediatric patients. Copyright © 2012 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jaffan, Abdel Aziz A., E-mail: aajaffan@gmail.com; Prince, Ethan A., E-mail: eprince@lifespan.org; Hampson, Christopher O., E-mail: christopherohampson@gmail.com
2013-06-15
Purpose. To establish the efficacy and safety of the preclose technique in total percutaneous endovascular aortic repair (PEVAR).MethodsA systematic literature search of Medline database was conducted for series on PEVAR published between January 1999 and January 2012.ResultsThirty-six articles comprising 2,257 patients and 3,606 arterial accesses were included. Anatomical criteria used to exclude patients from undergoing PEVAR were not uniform across all series. The technical success rate was 94 % per arterial access. Failure was unilateral in the majority (93 %) of the 133 failed PEVAR cases. The groin complication rate in PEVAR was 3.6 %; a minority (1.6 %) ofmore » these groin complications required open surgery. The groin complication rate in failed PEVAR cases converted to groin cutdown was 6.1 %. A significantly higher technical success rate was achieved when arterial access was performed via ultrasound guidance. Technical failure rate was significantly higher with larger sheath size ({>=}20F). Conclusion. The preclose technique in PEVAR has a high technical success rate and a low groin complication rate. Technical success tends to increase with ultrasound-guided arterial access and decrease with larger access. When failure occurs, it is unilateral in the majority of cases, and conversion to surgical cutdown does not appear to increase the operative risk.« less
Dong, Jun; Li, Wang; Zeng, Qi; Li, Sheng; Gong, Xiao; Shen, Lujun; Mao, Siyue; Dong, Annan; Wu, Peihong
2015-01-01
Abstract The location of the caudate lobe and its complex anatomy make caudate lobectomy and radiofrequency ablation (RFA) under ultrasound guidance technically challenging. The objective of the exploratory study was to introduce a novel modality of treatment of lesions in caudate lobe and discuss all details with our experiences to make this novel treatment modality repeatable and educational. The study enrolled 39 patients with liver caudate lobe tumor first diagnosed by computerized tomography (CT) or magnetic resonance imaging (MRI). After consultation of multi-disciplinary team, 7 patients with hepatic caudate lobe lesions were enrolled and accepted CT-guided percutaneous step-by-step RFA treatment. A total of 8 caudate lobe lesions of the 7 patients were treated by RFA in 6 cases and RFA combined with percutaneous ethanol injection (PEI) in 1 case. Median tumor diameter was 29 mm (range, 18–69 mm). A right approach was selected for 6 patients and a dorsal approach for 1 patient. Median operative time was 64 min (range, 59–102 min). Median blood loss was 10 mL (range, 8-16 mL) and mainly due to puncture injury. Median hospitalization time was 4 days (range, 2–5 days). All lesions were completely ablated (8/8; 100%) and no recurrence at the site of previous RFA was observed during median 8 months follow-up (range 3–11 months). No major or life-threatening complications or deaths occurred. In conclusion, percutaneous step-by-step RFA under CT guidance is a novel and effective minimally invasive therapy for hepatic caudate lobe lesions with well repeatability. PMID:26426638
Percutaneous Transhepatic Removal of Bile Duct Stones: Results of 261 Patients
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ozcan, Nevzat, E-mail: nevzatcan@yahoo.com; Kahriman, Guven, E-mail: guvenkahriman@hotmail.com; Mavili, Ertugrul, E-mail: ertmavili@yahoo.com
2012-08-15
Purpose: To determine the effectiveness of percutaneous transhepatic removal of bile duct stones when the procedure of endoscopic therapy fails for reasons of anatomical anomalies or is rejected by the patient. Methods: Between April 2001 and May 2010, 261 patients (138 male patients and 123 female patients; age range, 14-92 years; mean age, 64.6 years) with bile duct stones (common bile duct [CBD] stones = 248 patients and hepatolithiasis = 13 patients) were included in the study. Percutaneous transhepatic cholangiography was performed, and stones were identified. Percutaneous transhepatic balloon dilation of the papilla of Vater was performed. Then stones weremore » pushed out into the duodenum with a Fogarty balloon catheter. If the stone diameter was larger than 15 mm, then basket lithotripsy was performed before balloon dilation. Results: Overall success rate was 95.7%. The procedure was successful in 97.5% of patients with CBD stones and in 61.5% of patients with hepatolithiasis. A total of 18 major complications (6.8%), including cholangitis (n = 7), subcapsular biloma (n = 4), subcapsular hematoma (n = 1), subcapsular abscess (n = 1), bile peritonitis (n = 1), duodenal perforation (n = 1), CBD perforation (n = 1), gastroduodenal artery pseudoaneurysm (n = 1), and right hepatic artery transection (n = 1), were observed after the procedure. There was no mortality. Conclusion: Our experience suggests that percutaneous transhepatic stone expulsion into the duodenum through the papilla is an effective and safe approach in the nonoperative management of the bile duct stones. It is a feasible alternative to surgery when endoscopic extraction fails or is rejected by the patient.« less
Percutaneous Transhepatic Removal of Bile Duct Stones: Results of 261 Patients
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ozcan, Nevzat, E-mail: nevzatcan@yahoo.com; Kahriman, Guven, E-mail: guvenkahriman@hotmail.com; Mavili, Ertugrul, E-mail: ertmavili@yahoo.com
2012-06-15
Purpose: To determine the effectiveness of percutaneous transhepatic removal of bile duct stones when the procedure of endoscopic therapy fails for reasons of anatomical anomalies or is rejected by the patient. Methods: Between April 2001 and May 2010, 261 patients (138 male patients and 123 female patients; age range, 14-92 years; mean age, 64.6 years) with bile duct stones (common bile duct [CBD] stones = 248 patients and hepatolithiasis = 13 patients) were included in the study. First, percutaneous transhepatic cholangiography was performed and stones were identified. Percutaneous transhepatic balloon dilation of the papilla of Vater was performed. Then stonesmore » were pushed out into the duodenum with a Fogarty balloon catheter. If the stone diameter was larger than 15 mm, then basket lithotripsy was performed before balloon dilation. Results: Overall success rate was 95.7%. The procedure was successful in 97.5% of patients with CBD stones and in 61.5% of patients with hepatolithiasis. A total of 18 (6.8%) major complications, including cholangitis (n = 7), subcapsular biloma (n = 4), subcapsular hematoma (n = 1), subcapsular abscess (n = 1), bile peritonitis (n = 1), duodenal perforation (n = 1), CBD perforation (n = 1), gastroduodenal artery pseudoaneurysm (n = 1), and right hepatic artery transection (n = 1), were seen after the procedure. There was no mortality. Conclusion: Our experience suggests that percutaneous transhepatic stone expulsion into the duodenum through the papilla is an effective and safe approach in the nonoperative management of the bile duct stones. It is a feasible alternative to surgery when endoscopic extraction fails or is rejected by the patient.« less
Microwave treatment of renal cell carcinoma adjacent to renal sinus.
Gao, Yongyan; Liang, Ping; Yu, Xiaoling; Yu, Jie; Cheng, Zhigang; Han, Zhiyu; Duan, Shaobo; Huang, Hui
2016-11-01
To evaluate the efficacy and safety of ultrasound (US)-guided percutaneous microwave ablation (MWA) for renal cell carcinoma (RCC) adjacent to renal sinus. This retrospective study included 41 patients who underwent US-guided percutaneous MWA of 41 RCCs adjacent to the renal sinus from April 2006 to December 2015. Contrast-enhanced images of US and computed tomography (CT) or magnetic resonance (MR) imaging were performed at pre-ablation and 1day, 1 month, 3 months, and every 6 months after ablation. Initial ablation success (IAS), disease-free survival (DFS), RCC-related survival (RRS), and overall survival (OS) were recorded at the follow-up visits. IAS was achieved in 92.7% (38/41) of the study subjects. The IAS significantly differed between patients with RCCs ≤4cm (100%, 29/29) and RCCs >4cm (75%, 9/12, p=0.021). During the median follow-up of 37.6 (range, 3.0-97.3) months, the estimated 1-, 3-, and 5-year DFS of patients with an initial tumor of ≤4cm were 100%, 89.7%, and 81.5%, respectively. The 1-, 3-, and 5-year RRS were 100%, 93.3%, and 93.3%, respectively. The 1-, 3-, and 5-year OS were 97.1%, 87.8%, and 83.6%, respectively. The multivariate analysis using the Cox proportional hazard model revealed no independent predictor of recurrence among all the variables. There were no MWA-related deaths among the study subjects. One patient developed a retroperitoneal abscess after ablation. US-guided percutaneous MWA appears to be a promising method for RCCs adjacent to renal sinus, especially for tumors ≤4cm. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Conformal needle-based ultrasound ablation using EM-tracked conebeam CT image guidance
NASA Astrophysics Data System (ADS)
Burdette, E. Clif; Banovac, Filip; Diederich, Chris J.; Cheng, Patrick; Wilson, Emmanuel; Cleary, Kevin R.
2011-03-01
Numerous studies have demonstrated the efficacy of interstitial ablative approaches for the treatment of renal and hepatic tumors. Despite these promising results, current systems remain highly dependent on operator skill, and cannot treat many tumors because there is little control of the size and shape of the zone of necrosis, and no control over ablator trajectory within tissue once insertion has taken place. Additionally, tissue deformation and target motion make it extremely difficult to accurately place the ablator device into the target. Irregularly shaped target volumes typically require multiple insertions and several sequential thermal ablation procedures. This study demonstrated feasibility of spatially tracked image-guided conformal ultrasound (US) ablation for percutaneous directional ablation of diseased tissue. Tissue was prepared by suturing the liver within a pig belly and 1mm BBs placed to serve as needle targets. The image guided system used integrated electromagnetic tracking and cone-beam CT (CBCT) with conformable needlebased high-intensity US ablation in the interventional suite. Tomographic images from cone beam CT were transferred electronically to the image-guided tracking system (IGSTK). Paired-point registration was used to register the target specimen to CT images and enable navigation. Path planning is done by selecting the target BB on the GUI of the realtime tracking system and determining skin entry location until an optimal path is selected. Power was applied to create the desired ablation extent within 7-10 minutes at a thermal dose (>300eqm43). The system was successfully used to place the US ablator in planned target locations within ex-vivo kidney and liver through percutaneous access. Targeting accuracy was 3-4 mm. Sectioned specimens demonstrated uniform ablation within the planned target zone. Subsequent experiments were conducted for multiple ablator positions based upon treatment planning simulations. Ablation zones in liver were 73cc, 84cc, and 140cc for 3, 4, and 5 placements, respectively. These experiments demonstrate the feasibility of combining real-time spatially tracked image guidance with directional interstitial ultrasound ablation. Interstitial ultrasound ablation delivered on multiple needles permit the size and shape of the ablation zone to be "sculpted" by modifying the angle and intensity of the active US elements in the array. This paper summarizes the design and development of the first system incorporating thermal treatment planning and integration of a novel interstitial acoustic ablation device with integrated 3D electromagnetic tracking and guidance strategy.
Electromagnetic-Tracked Biopsy under Ultrasound Guidance: Preliminary Results
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hakime, Antoine, E-mail: thakime@yahoo.com; Deschamps, Frederic; Marques De Carvalho, Enio Garcia
2012-08-15
Purpose: This study was designed to evaluate the accuracy and safety of electromagnetic needle tracking for sonographically guided percutaneous liver biopsies. Methods: We performed 23 consecutive ultrasound-guided liver biopsies for liver nodules with an electromagnetic tracking of the needle. A sensor placed at the tip of a sterile stylet (18G) inserted in a coaxial guiding trocar (16G) used for biopsy was localized in real time relative to the ultrasound imaging plane, thanks to an electromagnetic transmitter and two sensors on the ultrasound probe. This allows for electronic display of the needle tip location and the future needle path overlaid onmore » the real-time ultrasound image. Distance between needle tip position and its electronic display, number of needle punctures, number of needle pull backs for redirection, technical success (needle positioned in the target), diagnostic success (correct histopathology result), procedure time, and complication were evaluated according to lesion sizes, depth and location, operator experience, and 'in-plane' or 'out-of-plane' needle approach. Results: Electronic display was always within 2 mm from the real position of the needle tip. The technical success rate was 100%. A single needle puncture without repuncture was used in all patients. Pull backs were necessary in six patients (26%) to obtain correct needle placement. The overall diagnostic success rate was 91%. The overall true-positive, true-negative, false-negative, and failure rates of the biopsy were 100% (19/19) 100% (2/2), 0% (0/23), and 9% (2/23). The median total procedure time from the skin puncture to the needle in the target was 30 sec (from 5-60 s). Lesion depth and localizations, operator experience, in-plane or out-of-plane approach did not affect significantly the technical, diagnostic success, or procedure time. Even when the tumor size decreased, the procedure time did not increase. Conclusions: Electromagnetic-tracked biopsy is accurate to determine needle tip position and allows fast and accurate needle placement in targeted liver nodules.« less
Deandrea, Maurilio; Limone, Paolo; Basso, Edoardo; Mormile, Alberto; Ragazzoni, Federico; Gamarra, Elena; Spiezia, Stefano; Faggiano, Antongiulio; Colao, Annamaria; Molinari, Filippo; Garberoglio, Roberto
2008-05-01
The aim of the study was to define the effectiveness and safety of ultrasound-guided percutaneous radiofrequency (RF) thermal ablation in the treatment of compressive solid benign thyroid nodules. Thirty-one patients not eligible for surgery or radioiodine (131I) treatment underwent RF ablation for benign nodules; a total of 33 nodules were treated (2 patients had 2 nodules treated in the same session): 10 cold nodules and 23 hyperfunctioning. Fourteen patients complained of compressive symptoms. Nodule volume, thyroid function and compressive symptoms were evaluated before treatment and at 1, 3 and 6 mo. Ultrasound-guided RF ablation was performed using a Starbust RITA needle, with nine expandable prongs; total exposure time was 6 to 10 min at 95 degrees C in one area or more of the nodule. Baseline volume (measured at the time of RF ablation) was 27.7 +/- 21.5 mL (mean +/- SD), but significantly decreased during follow-up: 19.2 +/- 16.2 at 1 mo (-32.7%; p < 0.001), 15.9 +/- 14.1 mL at 3 mo (-46.4 %; p < 0.001) and 14.6 +/- 12.6 mL at 6 mo (-50.7%; p < 0.001). After treatment, all patients with cold nodules remained euthyroid: five patients with hot nodules normalized thyroid function, and the remaining sixteen showed a partial remission of hyperthyroidism. Besides a sensation of heat and mild swelling of the neck, no major complications were observed. Improvement in compressive symptoms was reported by 13 patients, with a reduction on severity scale from 6.1 +/- 1.4 to 2.2 +/- 1.9 (p < 0.0001). Radiofrequency was effective and safe in reducing volume by about 50% and compressive symptoms in large benign nodules. Hyperfunction was fully controlled in 24% of patients and partially reduced in the others.
Ho, J T; Yap, C K
1999-05-01
The purpose of this study was to evaluate the accuracy of magnetic resonance cholangiopancreatography (MRCP) for visualisation and diagnosis of pancreatico-biliary diseases. Our results of 35 case studies, correlating with results from endoscopic, percutaneous cholangiopancreatography or laparotomy, showed that MRCP performed using the half-Fourier acquisition single-shot turbo spin echo (HASTE) sequences was fast and accurate for depiction of the biliary and pancreatic system, with a diagnostic value comparable to that of direct cholangiography. The presence of biliary obstruction was accurately diagnosed in all but one patient. In hilar strictures, MR cholangiogram was able to depict the intrahepatic biliary tree proximal to the level of obstruction which was not readily displayed by endoscopic retrograde cholangiopancreatography (ERCP) (Figs. 1 & 2). This overview of the entire biliary system was found to be advantageous for preprocedural planning. However, the accuracy for stone detection was limited by the presence of aerobilia from previous sphincterotomy or biliary-enteric anastomosis. Ductal stones less than 3 mm in size within a non-dilated system may be missed due to inadequate spatial resolution. This occurred in a patient with pancreatic duct stones. It is hoped that the accuracy of HASTE magnetic resonance cholangiopancreatography in evaluation of pancreatico-biliary disease would obviate the need for diagnostic invasive cholangiography in selected patients.
Del Castillo-González, Federico; Ramos-Álvarez, Juan José; Rodríguez-Fabián, Guillermo; González-Pérez, José; Calderón-Montero, Javier
2014-01-01
Summary Purpose: to evaluate the short and long term effectiveness of ultrasonography (US)-guided percutaneous needle lavage in calcific tendinopathy of the rotator cuff. To study the evolution of the size of calcifications and pain in the two years after treatment. Methods: a 2 year longitudinal prospective study is carried out after applying the UGPL technique on a number of patients diagnosed with calcific tendinitis of the rotator cuff. Clinical, ultrasound and radiology follow-up controls were performed, 3 months, 6 months, one year and two years after the treatment. The Visual Analog Scale (VAS) was used to assess the pain. The degree and point of pain is selected on a 10cm line, arranged horizontally or vertically. The “0” represents no pain and “10” represents worst pain. The population studied was made up of 121 patients that required our service as a result of suffering from a painful shoulder. Results: the pain (VAS) and the size of the calcification significantly decreased with the application of the technique (p< 0,001 in both cases) and regardless of the sex (p: 0.384 for pain and p: 0.578 for the size of the calcification). This occurred from the first check-up (3 months) and was maintained for two year. Conclusion: we consider this technique to be a valid alternative as a first-choice treatment of calcific tendinitis of the shoulder. The intervention is simple, cost-effective, does not require hospitalization, involves no complications, rehabilitation treatment is not required and it shows very few side effects without sequelae, significantly reducing the size of the calcification and pain in the majority of patients. PMID:25767776
Castillo-González, Federico Del; Ramos-Álvarez, Juan José; Rodríguez-Fabián, Guillermo; González-Pérez, José; Calderón-Montero, Javier
2014-01-01
Summary Background: to evaluate the short and long term effectiveness of ultrasonography (US)-guided percutaneous needle lavage in calcific tendinopathy of the rotator cuff. To study the evolution of the size of calcifications and pain in the two years after treatment. Methods: study design: A 2 year longitudinal prospective study is carried out after applying the UGPL technique on a number of patients diagnosed with calcific tendinitis of the rotator cuff. Clinical, ultrasound and radiology follow-up controls were performed, 3 months, 6 months, one year and two years after the treatment. The Visual Analog Scale (VAS) was used to assess the pain. The degree and point of pain is selected on a 10 cm line, arranged horizontally or vertically. The “0” represents no pain and “10” represents worst pain. The population studied was made up of 121 patients that required our service as a result of suffering from a painful shoulder. Results: the pain (VAS) and the size of the calcification significantly decreased with the application of the technique (p< 0,001 in both cases) and regardless of the sex (p: 0.384 for pain and p: 0.578 for the size of the calcification). This occurred from the first check-up (3 months) and was maintained for two year. Conclusions: we consider this technique to be a valid alternative as a first-choice treatment of calcific tendinitis of the shoulder. The intervention is simple, cost-effective, does not require hospitalization, involves no complications, rehabilitation treatment is not required and it shows very few side effects without sequelae, significantly reducing the size of the calcification and pain in the majority of patients. PMID:25332939
Percutaneous Embolization of Congenital Portosystemic Venous Fistula in an Infant with Down Syndrome
Tanya Chun, Pattaraporn; Files, Matthew; Vo, Nghia; McAdams, Ryan M.
2013-01-01
Congenital intrahepatic portosystemic venous shunts are rare vascular malformations often associated with severe complications. We describe a term male infant with Down syndrome with high output heart failure secondary to a congenital arterial to portal venous fistula that was diagnosed by Doppler ultrasound. Percutaneous embolizations of the left hepatic vein, portal vein, and communicating fistulas were performed without complications, resulting in clinical improvement. A subsequent hepatic ultrasound demonstrated resolution of the pathologic fistulous communication and shunting effects. PMID:24171135
Diagnostic laparoscopy-assisted cholangiography in infants with prolonged jaundice.
Okazaki, Tadaharu; Miyano, Go; Yamataka, Atsuyuki; Kobayashi, Hiroyuki; Koga, Hiroyuki; Lane, Geoffrey J; Miyano, Takeshi
2006-02-01
Cholangiography is often crucial for establishing the definitive cause of neonatal jaundice. We present our protocol for using laparoscopy-assisted cholangiography in infants with prolonged jaundice and discuss its benefits. Firstly, a 5 mm supra-umbilical trocar is introduced to create a port for a 0 degrees laparoscope. A 5 mm trocar is then inserted through a right subcostal incision to allow the liver and gallbladder to be visualized. If the gallbladder is of good size, the fundus is exteriorized through the right subcostal trocar site and a catheter is inserted into the gallbladder for cholangiography. If the gallbladder is atretic, the fundus is not exteriorized and a laparotomy is performed for open intraoperative cholangiography because the lumen of an atretic gallbladder is usually not fully patent and cholangiography through its exteriorized fundus often fails. We reviewed 18 jaundiced infants thought to have biliary atresia (BA) who had laparoscopy-assisted cholangiography. At laparoscopy, four patients had good sized gallbladders and minimal to mild liver fibrosis. They underwent cholangiography via the exteriorized fundus, and BA in two cases and biliary hypoplasia in two cases were identified. The remaining 14 had atretic gallbladders and varying degrees of liver fibrosis. Cholangiography via the exteriorized fundus was performed in one patient, but failed and converted to open cholangiography. Open intraoperative cholangiography identified BA in all 14 cases. All BA cases progressed to Kasai portoenterostomy directly after diagnosis. Laparoscopy is used to determine the type of cholangiography to be performed based on the appearance of the gallbladder and this simple, accurate, and safe protocol allows the anatomical structure of the biliary tree to be obtained accurately with minimal surgical intervention.
Treatment of Refractory Idiopathic Supraorbital Neuralgia Using Percutaneous Pulsed Radiofrequency.
Luo, Fang; Lu, Jingjing; Ji, Nan
2018-02-26
No ideal therapeutic method currently exists for refractory idiopathic supraorbital neuralgia patients who do not respond to conservative therapy, including medications and nerve blocks. Pulsed radiofrequency is a neuromodulation technique that does not produce sequelae of nerve damage after treatment. However, the efficacy of percutaneous pulsed radiofrequency for the treatment of refractory idiopathic supraorbital neuralgia is still not clear. The purpose of our study was to evaluate the efficacy and safety of pulsed radiofrequency treatment of the supraorbital nerve for refractory supraorbital neuralgia patients. We prospectively investigated the long-term effects of ultrasound-guided percutaneous pulsed radiofrequency in the treatment of 22 refractory idiopathic supraorbital neuralgia patients. A reduction in the verbal pain numeric rating scale score of more than 50% was used as the standard of effectiveness. The effectiveness rates at different time points within 2 years were calculated. After a single pulsed radiofrequency treatment, the effectiveness rate at 1 and 3 months was 77%, and the rates at 6 months, 1 year, and 2 years were 73%, 64%, and 50%, respectively. Except for a small portion of patients (23%) who experienced mild upper eyelid ecchymosis that gradually disappeared after approximately 2 weeks, no obvious complications were observed. In conclusion, the results of our study demonstrate that for patients with refractory idiopathic supraorbital neuralgia, percutaneous pulsed radiofrequency may be an effective and safe treatment choice. © 2018 World Institute of Pain.
Gigante, A; Moschini, A; Verdenelli, A; Del Torto, M; Ulisse, S; de Palma, L
2008-02-01
There is no agreement on the ideal type of surgical management for Achilles tendon rupture. The present randomized prospective study was performed to compare outcome data of open and percutaneous repair in the treatment of Achilles tendon rupture. Forty consecutive patients with acute rupture of Achilles tendon were recruited. Patients were randomized to receive open (group A) or percutaneous repair with Tenolig (group B). All patients followed the same rehabilitation protocol except for slight differences in the duration of immobilization. Follow-up included objective evaluation (at 4 and 12 months), subjective evaluation using the SF-12 questionnaire (at 24 months), and bilateral ultrasound scanning and isokinetic testing (at 12 months). The differences in the parameters evaluated clinically were not significant except for ankle circumference, which was significantly greater in group B. There were two minor complications in the open repair group and one case of failed repair in the percutaneous group. SF-12 questionnaire, ultrasound and isokinetic test data did not show significant differences between the groups. The present study demonstrates that the open and the percutaneous technique are both safe and effective in repairing the ruptured Achilles tendon and that both afford the same degree of restoration of clinical, ultrasound and isokinetic patterns. Medium-term results were substantially comparable. Percutaneous repair is performed on a day-surgery basis, it reduces cutaneous complications and operation times, and enables faster recovery, enhancing overall patient compliance. To us, these characteristics make it preferable to open repair in managing subcutaneous ruptures of Achilles tendon in non-professional sports practicing adults.
Occult Primary Neuroendocrine Tumor Metastasis to the Breast Detected on Screening Mammogram.
Policeni, Fabiana; Pakalniskis, Brittany; Yang, Limin
2016-01-01
Metastatic tumors are rare in the breast. Well-differentiated neuroendocrine tumors (WDNETs) are slow-growing neoplasms that arise from neuroendocrine cells, particularly in the gastrointestinal tract and bronchial tree. Metastatic WDNET to the breast is a rare entity. We present a case report of ileal WDNET metastatic to the breast which was initially identified as a small mass in the patient's left breast on screening mammography. Targeted ultrasound identified a suspicious mass, and ultrasound-guided percutaneous core biopsy was performed. Pathology revealed metastatic WDNET. Breast magnetic resonance imaging (MRI) was then performed and demonstrated left axillary Level 2 lymphadenopathy, and liver lesions were suspicious for metastasis. The patient underwent abdominal computed tomography (CT) to evaluate for distant metastatic disease. A spiculated mass was found near the ileocecal valve, suggestive of primary ileal WDNET. In addition, CT identified multiple liver lesions, most compatible with metastasis. Indium 111 OctreoScan confirmed radiotracer uptake in the ileum consistent with primary neuroendocrine tumor. In this report, we review the imaging characteristics of metastatic WDNET to the breast by different imaging modalities including mammogram, ultrasound, and breast MRI.
NASA Astrophysics Data System (ADS)
Rodrigues, Pedro L.; Rodrigues, Nuno F.; Fonseca, Jaime C.; von Krüger, M. A.; Pereira, W. C. A.; Vilaça, João. L.
2015-03-01
Background: Kidney stone is a major universal health problem, affecting 10% of the population worldwide. Percutaneous nephrolithotomy is a first-line and established procedure for disintegration and removal of renal stones. Its surgical success depends on the precise needle puncture of renal calyces, which remains the most challenging task for surgeons. This work describes and tests a new ultrasound based system to alert the surgeon when undesirable anatomical structures are in between the puncture path defined through a tracked needle. Methods: Two circular ultrasound transducers were built with a single 3.3-MHz piezoelectric ceramic PZT SN8, 25.4 mm of radius and resin-epoxy matching and backing layers. One matching layer was designed with a concave curvature to work as an acoustic lens with long focusing. The A-scan signals were filtered and processed to automatically detect reflected echoes. Results: The transducers were mapped in water tank and tested in a study involving 45 phantoms. Each phantom mimics different needle insertion trajectories with a percutaneous path length between 80 and 150 mm. Results showed that the beam cross-sectional area oscillates around the ceramics radius and it was possible to automatically detect echo signals in phantoms with length higher than 80 mm. Conclusions: This new solution may alert the surgeon about anatomical tissues changes during needle insertion, which may decrease the need of X-Ray radiation exposure and ultrasound image evaluation during percutaneous puncture.
Tutton, Sean; Olson, Erik; King, David; Shaker, Joseph L
2012-10-01
Tumor-induced osteomalacia is a rare condition usually caused by benign mesenchymal tumors. When the tumor can be found, patients are usually managed by wide excision of the tumor. We report a 51-yr-old male with clinical and biochemical evidence of tumor-induced osteomalacia caused by a mesenchymal tumor in the right iliac bone. He declined surgery and appears to have been successfully managed by computed tomography-guided percutaneous ethanol ablation and percutaneous cryoablation. Our patient appears to have had an excellent clinical and biochemical response to computed tomography-guided percutaneous ethanol ablation and percutaneous cryoablation. We found one prior case of image-guided ablation using radiofrequency ablation for tumor-induced osteomalacia. Although the standard treatment for tumor-induced osteomalacia is wide excision of the tumor, image-guided ablation may be an option in patients who cannot have appropriate surgery or who decline surgery.
Efficacy of preoperative biliary tract decompression in patients with obstructive jaundice.
Gundry, S R; Strodel, W E; Knol, J A; Eckhauser, F E; Thompson, N W
1984-06-01
Fifty consecutive matched patients with benign or malignant biliary tract obstruction were compared to determine the efficacy of preoperative percutaneous biliary drainage (PBD). Twenty-five patients underwent PBD for an average of nine days before operation; 25 patients underwent percutaneous transhepatic cholangiography ( PTHC ) followed immediately by operation. Serum bilirubin levels before PTHC were 16.5 +/- 7.6 mg/dL and 14.9 +/- 7.6 mg/dL in PBD and non-PBD groups, respectively. Serum bilirubin levels decreased to 6.5 +/- 6.2 mg/dL preoperatively in patients having PBD. One week after operation, bilirubin levels were 4.2 +/- 4.3 mg/dL and 9.0 +/- 5.2 mg/dL in the PBD and non-PBD groups, respectively. Major morbidity (sepsis, abscess, renal failure, or bleeding) occurred in two patients (8%) having PBD and in 13 patients (52%) without PBD. One patient (4%) with PBD, and five patients (20%) without PBD, died. The mean hospital stay was shorter for the PBD group. Preoperative PBD reduces operative mortality and morbidity and results in a more rapid resolution of hyperbilirubinemia during the postoperative period.
Vascular Complications of Pancreatitis: Role of Interventional Therapy
Lopera, Jorge E.
2012-01-01
Major vascular complications related to pancreatitis can cause life-threatening hemorrhage and have to be dealt with as an emergency, utilizing a multidisciplinary approach of angiography, endoscopy or surgery. These may occur secondary to direct vascular injuries, which result in the formation of splanchnic pseudoaneurysms, gastrointestinal etiologies such as peptic ulcer disease and gastroesophageal varices, and post-operative bleeding related to pancreatic surgery. In this review article, we discuss the pathophysiologic mechanisms, diagnostic modalities, and treatment of pancreatic vascular complications, with a focus on the role of minimally-invasive interventional therapies such as angioembolization, endovascular stenting, and ultrasound-guided percutaneous thrombin injection in their management. PMID:22563287
Rapid diagnosis of liver cancer by ultrasound-guided fine-needle aspiration biopsy.
Huber, K; Heuhold, N
1987-01-01
Because of the relatively favorable prognosis to the patient with early detected hepatocarcinoma followed by surgical treatment if resection is possible, it is important to differentiate quickly between primary and secondary liver cancer. Ultrasound-guided percutaneous fine needle aspiration biopsy (US-FNAB) was used as a first diagnostic measure in patients with sonographic evidence of liver tumors. Biopsies were done under sonographic control and antiseptic conditions from the center and the border zone of solid tumors of the liver, and the aspirated cell material was air dried on glass slides and Giemsa stained. The cytologic diagnosis was proved by clinical course and in most cases by surgical or autoptic histology. Cytologic evaluation lead in 15 cases to the diagnosis of definitive or suspicious malignant liver disease; the sensitivity was 93% and the specificity was 87%. One case classified as suspicious for malignancy by cytologic examination could be identified as cirrhotic nodule by further investigations. In none of the patients did we find complications from the biopsy procedure. From these data it is concluded that US-FNAB can serve as a rapid, inexpensive, safe, and highly accurate first diagnostic step in patients with solid lesions of the liver.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sabharwal, Rohan, E-mail: rohan50000@yahoo.com; Vladica, Philip
2006-04-15
Purpose. To evaluate the feasibility, safety, and technical efficacy of image-guided radiofrequency ablation (RFA) for the treatment of small peripheral renal tumors and to report our early results with this treatment modality. Methods. Twenty-two RFA sessions for 18 tumors were performed in 11 patients with renal tumors. Indications included coexistent morbidity, high surgical or anesthetic risk, solitary kidney, and hereditary predisposition to renal cell carcinoma. Ten patients had CT-guided percutaneous RFA performed on an outpatient basis. One patient had open intraoperative ultrasound-guided RFA. Technical success was defined as elimination of areas that enhanced at imaging within the entire tumor. Withmore » the exception of one patient with renal insufficiency who required gadolinium-enhanced MRI, the remaining patients underwent contrast-enhanced CT for post-treatment follow-up assessment. Follow-up was performed after 2-4 weeks and then at 3, 6, 12 months, and every 12 months thereafter. Results. Fourteen (78%) of 18 tumors were successfully ablated with one session. Three of the remaining four tumors required two sessions for successful ablation. One tumor will require a third session for areas of persistent enhancement. Mean patient age was 72.82 {+-} 10.43 years. Mean tumor size was 1.95 {+-} 0.79 cm. Mean follow-up time was 10.91 months. All procedures were performed without any major complications. Conclusions. Our early experience with percutaneous image-guided radiofrequency ablation demonstrates it to be a feasible, safe, noninvasive, and effective treatment of small peripheral renal tumors.« less
Pasquotti, Giulio; Faccinetto, Alex; Marchioro, Umberto; Todisco, Matteo; Baldo, Vincenzo; Cocchio, Silvia; De Conti, Giorgio
2016-08-01
To monitor the results of ultrasound (US)-guided percutaneous treatment of calcific tendinopathy of the shoulder at 12 months (T12) after treatment (T0). To verify the possible relations between some pre- and post-procedural variables with the clinical outcome at T12. Forty-seven patients (26 female and 21 male) were enrolled in the study. Patients' approval and written informed consent were obtained. Symptoms were assessed by Constant Shoulder Score (CSS) at T0 and T12. Thirty of these also underwent a CSS control at 3 months (T3). The treatment efficacy was statistically tested for relation with location and type of calcification, characteristics of the tendon and subdeltoid bursa, impingement, and rehabilitation treatments. There was a significant increase in the average CSS value between T0 and T12 (40.7 vs. 75.3). The variables analysed did not show a statistically significant effect on the outcome at T12. A link was noticed only between patients' increasing age and score improvement, particularly among female subjects. US-guided treatment of calcific tendonitis is a viable therapeutic option. No pre- or intra-procedural parameters emerged which might help in predicting the outcome, apart from patients' needs in everyday life. • US-guided tcreatment of shoulder calcific tendinopathy is an excellent therapeutic option • Long-term results seem greatly affected by patients' features and needs in everyday life • No proven pre- or intra-procedural parameters emerged that might predict the outcome.
Kennedy, Sean A.; Milovanovic, Lazar; Midia, Mehran
2015-01-01
Major bleeding remains an uncommon yet potentially devastating complication following percutaneous image-guided biopsy. This article reviews two cases of major bleeding after percutaneous biopsy and discusses the frequency, predictors, and periprocedural management of major postprocedural bleeding. PMID:25762845
Qiu, X; Lü, B; Xu, N; Yan, C W; Ouyang, W B; Liu, Y; Zhang, F W; Yue, Z Q; Pang, K J; Pan, X B
2017-04-25
Objective: To investigate the feasibility of trans-catheter closure of multiple atrial septal defects (ASD) monitored by trans-thoracic echocardiography (TTE) under the guidance of 3D printing heart model. Methods: Between April and August 2016, a total of 21 patients (8 male and 13 female) with multiple ASD in Fuwai Hospital of Chinese Academy of Medical Sciences underwent CT scan and 3-dimensional echocardiography for heart disease model produced by 3D printing technique. The best occlusion program was determined through the simulation test on the model. Percutaneous device closure of multiple ASD was performed follow the predetermined program guided by TTE. Clinical follow-up including electrocardiogram and TTE was arranged at 1 month after the procedure. Results: The trans-catheter procedure was successful in all 21 patients using a single atrial septal occluder. Mild residual shunt was found in 5 patient in the immediate postoperative period, 3 of them were disappeared during postoperative follow-up. There was no death, vascular damage, arrhythmia, device migration, thromboembolism, valvular dysfunction during the follow-up period. Conclusion: The use of 3D printing heart model provides a useful reference for transcatheter device closure of multiple ASD achieving through ultrasound-guided intervention technique, which appears to be safe and feasible with good outcomes of short-term follow-up.
Girometti, R; Brondani, G; Cereser, L; Como, G; Del Pin, M; Bazzocchi, M; Zuiani, C
2010-01-01
Post-cholecystectomy syndrome (PCS) is defined as a complex of heterogeneous symptoms, consisting of upper abdominal pain and dyspepsia, which recur and/or persist after cholecystectomy. Nevertheless, this term is inaccurate, as it encompasses biliary and non-biliary disorders, possibly unrelated to cholecystectomy. Biliary manifestations of PCS may occur early in the post-operative period, usually because of incomplete surgery (retained calculi in the cystic duct remnant or in the common bile duct) or operative complications, such as bile duct injury and/or bile leakage. A later onset is commonly caused by inflammatory scarring strictures involving the sphincter of Oddi or the common bile duct, recurrent calculi or biliary dyskinesia. The traditional imaging approach for PCS has involved ultrasound and/or CT followed by direct cholangiography, whereas manometry of the sphincter of Oddi and biliary scintigraphy have been reserved for cases of biliary dyskinesia. Because of its capability to provide non-invasive high-quality visualisation of the biliary tract, magnetic resonance cholangiopancreatography (MRCP) has been advocated as a reliable imaging tool for assessing patients with suspected PCS and for guiding management decisions. This paper illustrates the rationale for using MRCP, together with the main MRCP biliary findings and diagnostic pitfalls. PMID:20335441
Emerging Technologies for the Diagnosis of Perihilar Cholangiocarcinoma.
Rizvi, Sumera; Eaton, John; Yang, Ju Dong; Chandrasekhara, Vinay; Gores, Gregory J
2018-05-01
The diagnosis of malignant biliary strictures remains problematic, especially in the perihilar region and in primary sclerosing cholangitis (PSC). Conventional cytology obtained during endoscopic retrograde cholangiography (ERC)-guided brushings of biliary strictures is suboptimal due to limited sensitivity, albeit it remains the gold standard with a high specificity. Emerging technologies are being developed and validated to address this pressing unmet patient need. Such technologies include enhanced visualization of the biliary tree by cholangioscopy, intraductal ultrasound, and confocal laser endomicroscopy. Conventional cytology can be aided by employing complementary and advanced cytologic techniques such as fluorescent in situ hybridization (FISH), and this technique should be widely adapted. Interrogation of bile and serum by examining extracellular vesicle number and cargo, and exploiting next-generation sequencing and proteomic technologies, is also being explored. Examination of circulating cell-free deoxyribonucleic acid (cfDNA) for differentially methylated regions is a promising test which is being rigorously validated. The special expertise required for these analyses has to date hampered their validation and adaptation. Herein, we will review these emerging technologies to inform the reader of the progress made and encourage further studies, as well as adaptation of validated approaches. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Hirose, Tomoaki; Igami, Tsuyoshi; Koga, Kusuto; Hayashi, Yuichiro; Ebata, Tomoki; Yokoyama, Yukihiro; Sugawara, Gen; Mizuno, Takashi; Yamaguchi, Junpei; Mori, Kensaku; Nagino, Masato
2017-03-01
Fusion angiography using reconstructed multidetector-row computed tomography (MDCT) images, and cholangiography using reconstructed images from MDCT with a cholangiographic agent include an anatomical gap due to the different periods of MDCT scanning. To conquer such gaps, we attempted to develop a cholangiography procedure that automatically reconstructs a cholangiogram from portal-phase MDCT images. The automatically produced cholangiography procedure utilized an original software program that was developed by the Graduate School of Information Science, Nagoya University. This program structured 5 candidate biliary tracts, and automatically selected one as the candidate for cholangiography. The clinical value of the automatically produced cholangiography procedure was estimated based on a comparison with manually produced cholangiography. Automatically produced cholangiograms were reconstructed for 20 patients who underwent MDCT scanning before biliary drainage for distal biliary obstruction. The procedure showed the ability to extract the 5 main biliary branches and the 21 subsegmental biliary branches in 55 and 25 % of the cases, respectively. The extent of aberrant connections and aberrant extractions outside the biliary tract was acceptable. Among all of the cholangiograms, 5 were clinically applied with no correction, 8 were applied with modest improvements, and 3 produced a correct cholangiography before automatic selection. Although our procedure requires further improvement based on the analysis of additional patient data, it may represent an alternative to direct cholangiography in the future.
NASA Astrophysics Data System (ADS)
Rodrigues, Pedro L.; Rodrigues, Nuno F.; Fonseca, Jaime C.; Vilaça, João. L.
2015-03-01
An accurate percutaneous puncture is essential for disintegration and removal of renal stones. Although this procedure has proven to be safe, some organs surrounding the renal target might be accidentally perforated. This work describes a new intraoperative framework where tracked surgical tools are superimposed within 4D ultrasound imaging for security assessment of the percutaneous puncture trajectory (PPT). A PPT is first generated from the skin puncture site towards an anatomical target, using the information retrieved by electromagnetic motion tracking sensors coupled to surgical tools. Then, 2D ultrasound images acquired with a tracked probe are used to reconstruct a 4D ultrasound around the PPT under GPU processing. Volume hole-filling was performed in different processing time intervals by a tri-linear interpolation method. At spaced time intervals, the volume of the anatomical structures was segmented to ascertain if any vital structure is in between PPT and might compromise the surgical success. To enhance the volume visualization of the reconstructed structures, different render transfer functions were used. Results: Real-time US volume reconstruction and rendering with more than 25 frames/s was only possible when rendering only three orthogonal slice views. When using the whole reconstructed volume one achieved 8-15 frames/s. 3 frames/s were reached when one introduce the segmentation and detection if some structure intersected the PPT. The proposed framework creates a virtual and intuitive platform that can be used to identify and validate a PPT to safely and accurately perform the puncture in percutaneous nephrolithotomy.
Choudhary, Narendra S; Puri, Rajesh; Saigal, Sanjiv; Bhangui, Prashant; Saraf, Neeraj; Shah, Vinit; Nasa, Mukesh; Sarin, Haimanti; Guleria, Mridula; Sud, Randhir; Soin, Arvinder S
2016-11-01
Diagnosis of metastatic disease is important in patients with cirrhosis and hepatocellular carcinoma (HCC) to prevent futile liver transplantation. Some of these patients have metastatic lymphadenopathy; however, it is difficult to perform percutaneous fine-needle aspiration due to presence of collateral and anatomic location. Endoscopic ultrasound (EUS)-guided fine-needle aspiration (FNA) of lymph nodes offers several advantages like real-time vision, proximity to target, and avoidance of collaterals. The aim of this study was to look for metastatic lymphadenopathy by EUS-guided FNA (EUS-FNA) in prospective liver transplant recipients with HCC. A prospective study was conducted from January 2013 to January 2016 at a tertiary care center. All prospective liver transplant recipients with HCC had PET-CT and bone scan to look for metastatic disease. EUS-FNA was done in patients with abdominal or mediastinal lymphadenopathy and no evidence of extrahepatic disease. Data is shown as median (25-75 interquartile range). EUS-guided FNA was done for 50 patients (42 abdominal and 8 mediastinal lymph nodes), age 57 (53-62) years, Child-Turcotte-Pugh 7 (6-9), and model for end-stage liver disease 10 (7-16). FNA material was adequate in 92% patients, metastasis in 15 (30%), granulomatous lymphadenopathy in 4 (8%), and reactive change in 27 patients (54%). The material was inadequate for diagnosis in 4 (8%) patients. Thus, EUS-guided FNA precluded transplantation in 30% of patients with lymphadenopathy, and 4 (8%) patients received anti-tubercular therapy before liver transplantation. In patients with HCC and lymphadenopathy, EUS-guided FNA detected metastatic disease and precluded liver transplantation in approximately one third of patients.
Ragazzi, S; Vanzulli, A; Del Maschio, A; Tomaselli, V; Dell' Agnola, C A
2007-12-01
The aim of the study was to evaluate fast magnetic resonance cholangio-pancreatography (MRCP) sequences as an alternative and safe investigation method for neonatal and children's pancreaticobiliary diseases. Between January 2000 and December 2000, five children (age: 1 month 14 years; mean: 7 years) affected by pancreaticobiliary diseases or already operated for biliary pathologies were studied. Patients were evaluated by 1.5 T magnet single shot T2-weighted sequences (1 image per s, TR = infinite, TE = 150-180 ms). T1-weighted conventional sequences were obtained to study parenchymal tissue. No patient needed general anaesthetic. Only in one case was sedation necessary. Fast MRCP sequences provided very precise information on biliary tract anatomy. They revealed the intra and extrahepatic bile ducts, the gallbladder, the common bile duct and the bilio-pancreatic junction in all cases investigated. MRCP allowed us to evaluate Roux-en-Y type bilio-enteric anastomosis as accurately as percutaneous transhepatic cholangiography (PTC). In addition MRCP was the only reliable study in evaluating Roux-en-Y type anastomosis where ultrasonography (US) and endoscopic retrograde cholangiography (ERCP) could not be used. In conclusion MRCP is an accurate and non-invasive method with which to investigate the anatomy of the pancreaticobiliary tract in children. It could become the investigation of choice after US in the case of biliary and pancreatic diseases.
Yakoubi, Rachid; Autorino, Riccardo; Laydner, Humberto; Guillotreau, Julien; White, Michael A; Hillyer, Shahab; Spana, Gregory; Khanna, Rakesh; Isaac, Wahib; Haber, Georges-Pascal; Stein, Robert J; Kaouk, Jihad H
2012-06-01
The aim of this study was to evaluate a novel ultrasound probe specifically developed for robotic surgery by determining its efficiency in identifying renal tumors. The study was carried out using the Da Vinci™ surgical system in one female pig. Renal tumor targets were created by percutaneous injection of a tumor mimic mixture. Single-port and standard robotic partial nephrectomy were performed. Intraoperative ultrasound was performed using both standard laparoscopic probe and the new ProART™ Robotic probe. Probe maneuverability and ease of handling for tumor localization were recorded. The standard laparoscopic probe was guided by the assistant. Significant clashing with robotic arms was noted during the single-port procedure. The novel robotic probe was easily introduced through the assistant trocar, and held by the console surgeon using the robotic Prograsp™ with no registered clashing in the external operative field. The average time for grasping the new robotic probe was less than 10 s. Once inserted and grasped, no limitation was found in terms of instrument clashing during the single-port procedure. This novel ultrasound probe developed for robotic surgery was noted to be user-friendly when performing porcine standard and especially single-port robotic partial nephrectomy. Copyright © 2011 John Wiley & Sons, Ltd.
Botulinum toxin injection - larynx
Injection laryngoplasty; Botox - larynx: spasmodic dysphonia-BTX; Essential voice tremor (EVT)-btx; Glottic insufficiency; Percutaneous electromyography - guided botulinum toxin treatment; Percutaneous indirect laryngoscopy - guided botulinum toxin treatment; ...
Percutaneous intrapericardial echocardiography during catheter ablation: a feasibility study.
Horowitz, Barbara Natterson; Vaseghi, Marmar; Mahajan, Aman; Cesario, David A; Buch, Eric; Valderrábano, Miguel; Boyle, Noel G; Ellenbogen, Kenneth A; Shivkumar, Kalyanam
2006-11-01
Percutaneous pericardial access, epicardial mapping, and ablation have been used successfully for catheter ablation procedures. The purpose of this study was to evaluate the safety and feasibility of closed-chest direct epicardial ultrasound imaging for aiding cardiac catheter ablation procedures. An intracardiac ultrasound catheter was used for closed-chest epicardial imaging of the heart in 10 patients undergoing percutaneous epicardial access for catheter ablation. All patients underwent concomitant intracardiac echocardiography and preprocedural transesophageal echocardiography. Using a double-wire technique, two sheaths were placed in the pericardium, and a phased-array ultrasound catheter was manipulated within the pericardial sinuses for imaging. Multiple images from varying angles were obtained for catheter navigation. Notably, image stability was excellent, and structures such as the left atrial appendage were seen in great detail. No complications resulting from use of the ultrasound catheter in the pericardium occurred, and no restriction of movement due to the presence of the additional catheter in the pericardial space was observed. Wall motion was correlated to voltage maps in five patients and showed that areas of scars correlated with wall-motion abnormalities. Normal wall-motion score correlated to sensed signals of 4.2 +/- 0.3 mV (normal myocardium >1.5 mV), and scores >1 correlated to areas with signals <0.5 mV in that territory). Intrapericardial imaging using an ultrasound catheter is feasible and safe and has the potential to provide additional valuable information for complex ablation procedures.
[Gallbladder agenesis. Case report].
Cavazos-García, Ricardo; Díaz-Elizondo, José Antonio; Flores-Villalba, Eduardo; Rodríguez-García, Héctor Alejandro
2015-01-01
Gallbladder agenesis is a very rare congenital abnormality of the biliary tract. The diagnosis is made during surgery, because all preoperative studies have failed to identify this malformation. The purpose of this article is to present a case of gallbladder agenesis diagnosed during surgery, its management, and a review of the literature. The case involves a sixty-two year- old female, referring to repeated biliary colic symptoms. The abdominal ultrasound diagnosed cholelithiasis. It was impossible to identify the gallbladder during surgery. Diagnosis was confirmed by intra-operative cholangiography. Preoperative diagnostic workup has failed to recognise patients with gallbladder agenesis. It is currently recommended to abandon the surgery once this diagnosis is suspected and confirm it by a cholangio-magnetic resonance scan in order to avoid a bile duct injury. Agenesis of the gallbladder is a rare congenital abnormality of the biliary tree. Every surgeon must keep this rare entity in mind when a "difficult dissection" or an anatomic variant is identified during surgery, and make use of an intra-operative cholangiography, mainly to prevent a bile duct injury. Copyright © 2015 Academia Mexicana de Cirugía A.C. Published by Masson Doyma México S.A. All rights reserved.
Gallbladder Agenesis in 17 Dogs: 2006-2016.
Sato, K; Sakai, M; Hayakawa, S; Sakamoto, Y; Kagawa, Y; Kutara, K; Teshima, K; Asano, K; Watari, T
2018-01-01
Gallbladder agenesis (GBA) is extremely rare in dogs. To describe the history, clinical signs, diagnosis, treatment, and outcomes of dogs with GBA. Seventeen client-owned dogs with GBA. Medical records from 2006 through 2016 were retrospectively reviewed. Dogs were included when GBA was suspected on abdominal ultrasonography and confirmed by gross evaluation. Signalment, clinical signs, clinicopathological data, diagnostic imaging, histopathology, treatment, and outcome were recorded. Dogs were of 6 different breeds, and Chihuahuas (10 of 17) were most common. Median age at presentation was 1.9 (range, 0.7-7.4) years. Clinical signs included vomiting (5 of 17), anorexia (2 of 17), ascites (2 of 17), diarrhea (1 of 17), lethargy (1 of 17), and seizures (1 of 17). All dogs had increased serum activity of at least 1 liver enzyme, most commonly alanine aminotransferase (15 of 17). Fifteen dogs underwent computed tomography (CT) cholangiography; common bile duct (CBD) dilatation was confirmed in 12, without evidence of bile duct obstruction. Gross evaluation confirmed malformation of the liver lobes in 14 of 17 dogs and acquired portosystemic collaterals in 5 of 17. Ductal plate malformation was confirmed histologically in 16 of 17 dogs. During follow-up (range, 4-3,379 days), 16 of 17 dogs remained alive. Dogs with GBA exhibit clinicopathological signs of hepatobiliary injury and hepatic histopathological changes consistent with a ductal plate abnormality. Computed tomography cholangiography was superior to ultrasound examination in identifying accompanying nonobstructive CBD distention. Computed tomography cholangiography combined with laparoscopic liver biopsy is the preferable approach to characterize the full disease spectrum accompanying GBA in dogs. Copyright © 2018 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.
[Renal biopsy in the lateral position in high risk patients: an opportunity to take advantage of].
Dugo, Mauro; Brisotto, Elisa; Vitturi, Nicola; Pasi, Alessandra; Mastrosimone, Stefania; Farneti, Fabrizio; Mangino, Margherita; Virgilio, Bice; Brunello, Anna; Pastori, Giordano; Mazzoli, Matteo; Laurino, Licia; Cova, Giandavide; Beniamin, Francesco; Maresca, Maria Cristina
2015-01-01
Percutaneous ultrasound-guided renal biopsy (RB) is the gold standard for diagnosis of renal diseases. The standard procedure involves biopsy in the prone position (PP) for the native kidneys. In high risk patients, transjugular and laparoscopic RB have been proposed. In patients suffering from obesity or respiratory diseases, the RB of the native kidney in the supine anterolateral position (SALP) represents an alternative to these invasive and expensive methods. We illustrate the technique of execution of RB in the lateral position (LP) on native kidneys. The procedure is safe, effective and has reduced the path travelled by the needle biopsy compared with PP and SALP.
Abat, F; Gelber, P E; Polidori, F; Monllau, J C; Sanchez-Ibañez, J M
2015-04-01
To investigate the outcome of ultrasound (US)-guided intratissue percutaneous electrolysis (EPI(®)) and eccentric exercise in the treatment of patellar tendinopathy during a long-term follow-up. Forty patients with patellar tendinopathy were prospectively evaluated over a 10-year follow-up period. Pain and function were evaluated before treatment, at 3 months and at 2, 5 and 10 years using the Victorian Institute of Sport Assessment-Patella (VISA-P) score, the Tegner score and Blazina's classification. According to VISA-P score at baseline, patients were also dichotomized into Group 1 (<50 points) and Group 2 (≥50 points). There were 21 patients in Group 1 and 19 in Group 2. Patient satisfaction was measured according to the Roles and Maudsley score. The VISA-P score improved globally by 41.2 points (p < 0.01) after a mean 4.1 procedures. In Group 1, VISA-P score improved from 33.1 ± 13 to 78.9 ± 14.4 at 3-month and to 88.8 ± 10.1 at 10-year follow-up (p < 0.001). In Group 2, VISA-P score improved from 69.3 ± 10.5 to 84.9 ± 9 at 3-month and to 96.0 ± 4.3 at 10-year follow-up (p < 0.001). After 10 years, 91.2 % of the patients had a VISA-P score >80 points. The same level (80 % of patients) or the Tegner score at no more than one level lower (20 % of patients) was restored, and 97.5 % of the patients were satisfied with the procedure. Treatment with the US-guided EPI(®) technique and eccentric exercises in patellar tendinopathy resulted in a great improvement in knee function and a rapid return to the previous level of activity after few sessions. The procedure has proved to be safe with no recurrences on a long-term basis. Therapeutic study, Level IV.
Percutaneous Treatment of Iatrogenic Pseudoaneurysms by Cyanoacrylate-Based Wall-Gluing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Del Corso, Andrea, E-mail: adelcorso2000@hotmail.com; Vergaro, Giuseppe
Purpose. Although the majority of iatrogenic pseudoaneurysms (PSAs) are amenable to ultrasound (US)-guided thrombin injection, patients with those causing neuropathy, claudication, significant venous compression, or soft tissue necrosis are considered poor candidates for this option and referred to surgery. We aimed to test the effectiveness and feasibility of a novel percutaneous cyanoacrylate glue (NBCA-MS)-based technique for treatment of symptomatic and asymptomatic iatrogenic PSA. Material and Methods. During a 3-year period, we prospectively enrolled 91 patients with iatrogenic PSA [total n = 94 (femoral n = 76; brachial n = 11; radial n = 6; axillary n = 1)]. PSA weremore » asymptomatic in 66 % of cases, and 34 % presented with symptoms due to neuropathy, venous compression, and/or soft tissue necrosis. All patients signed informed consent. All patients received NBCA-MS-based percutaneous treatment. PSA chamber emptying was first obtained by US-guided compression; superior and inferior walls of the PSA chamber were then stuck together using NBCA-MS microinjections. Successfulness of the procedure was assessed immediately and at 1-day and 1-, 3-, and 12-month US follow-up. Results. PSA occlusion rate was 99 % (93 of 94 cases). After treatment, mean PSA antero-posterior diameter decrease was 67 {+-} 22 %. Neuropathy and vein compression immediately disappeared in 91 % (29 of 32) of cases. Patients with tissue necrosis (n = 6) underwent subsequent outpatient necrosectomy. No distal embolization occurred, nor was conversion to surgery necessary. Conclusion. PSA treatment by way of NBCA-MS glue injection proved to be safe and effective in asymptomatic patients as well as those with neuropathy, venous compression, or soft-tissue necrosis (currently candidates for surgery). Larger series are needed to confirm these findings.« less
Bronchobiliary Fistula Treated by Self-expanding ePTFE-Covered Nitinol Stent-Graft
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gandini, Roberto; Konda, Daniel; Tisone, Giuseppe
A 71-year-old man, who had undergone right hepatectomy extended to the caudate lobe with terminolateral Roux-en-Y left hepatojejunostomy for a Klatskin tumor, developed bilioptysis 3 weeks postoperatively due to bronchobiliary fistula. Percutaneous transhepatic cholangiography revealed a non-dilated biliary system with contrast medium extravasation to the right subphrenic space through a resected anomalous right posterior segmental duct. After initial unsuccessful internal-external biliary drainage, the fistula was sealed with a VIATORR covered self-expanding nitinol stent-graft placed with its distal uncovered region in the hepatojejunal anastomosis and the proximal ePTFE-lined region in the left hepatic duct. A 10-month follow-up revealed no recurrence ofmore » bilioptysis and confirmed the complete exclusion of the bronchobiliary fistula.« less
Changes associated with percutaneous ethanol injection in the treatment of thyroid nodules.
Schrut, Gianna Carla Alberti; Miasaki, Fabíola Yukiko; Paz-Filho, Gilberto; Cavalcanti, Teresa Cristina Santos; Graf, Hans; de Carvalho, Gisah Amaral
2011-06-01
Percutaneous ethanol injection (PEI) is an alternative therapy for thyroid nodules (TN). However, some concern is raised on its carcinogenic effects. To evaluate the cytological and clinical changes caused by PEI in patients with benign TN. Thirty-nine patients with TN (23.1% hyperfunctioning) were submitted to a median of three PEI sessions. After a median of 17 months, patients were reassessed. A new ultrasound-guided fine needle biopsy (US-FNB) was performed, and the smears were analyzed after May-Grünwald-Giemsa staining. The diagnostic findings and the cellular characteristics were compared before and after treatment. There was an increase in the proportion of nondiagnostic/unsatisfactory results (from 2.5% to 18.9%). No malignant cases were observed. The proportion of moderate/intense macrophage infiltration decreased from 60% to 15%. Before treatment, 23.1% patients had hyperthyroidism, which was completely or partially resolved in 66.7%. By ultrasound, the percentage of homogeneous nodules decreased from 64.0% to 38.4% (p=0.0235), and the mean nodule volume decreased from 13.4 ± 12.2 to 5.3 ± 5.1 cm(3). We demonstrate that PEI increases the proportion of nondiagnostic/unsatisfactory results from US-FNB. Therefore, cytological findings after PEI must be evaluated with caution. Our results also suggest that PEI is an efficacious and safe therapeutic option, with no carcinogenic effects observed on cytological evaluations. Safety and efficacy must be evaluated in larger studies with longer follow-up periods.
Batchelor, Wayne; Dahya, Vishal; McGee, Dan; Katopodis, John; Dixon, William; Campbell, James; Meredith, Ashley; Knap, Patty; Parkin, Mathew; Noel, Thomas
2018-04-01
There exist limited data on the relative degree of acute injury and late healing of the radial artery after transradial artery (TRA) percutaneous coronary intervention (PCI) with a 7F sheathless guide catheter compared with a 6F sheath/guide combination. We used ultrahigh-resolution (55 MHz) vascular ultrasound to compare intimal-medial thickening (IMT) and early and late radial artery (RA) injury resulting from a sheathless 7F guide catheter versus a 6F sheath/guide combination for TRA-PCI. Forty-one consecutive consenting patients undergoing elective nonemergent TRA-PCI at a single institution from June 2016 to December 2016 were included. Patients were randomized (stratified by sex) to undergo TRA-PCI using a 7F sheathless guide catheter versus a 6F sheath/6F guide combination. Ultrahigh-resolution vascular ultrasound (55MHz) of the RA access site was performed at 24hours and 90days post-TRA-PCI. The primary outcome of the study was a noninferiority comparison of radial artery IMT thickness at 90days. PCI success rates, fluoroscopy times, number of guides used, and crossover rates to a femoral approach were also compared. Baseline characteristics were similar between groups. Radial arterial IMT (mm) was similar between the 7F sheathless and 6F sheath/guide groups at 24hours (0.27 vs 0.29, respectively; P=.43) and at 90days (0.35 vs 0.34, respectively; P=.96). The P value for the noninferiority testing of a 0.07-mm limit was .002. Limited access site intimal tears were relatively common in both groups at 24hours (4 vs 5, P=.53) but often healed by 90days. Radial artery occlusion was infrequent at 90days (2 vs 1, P=.10), and no frank dissections were noted. PCI success rates (100% vs 95%, P=.59), fluoroscopy times (16 vs 12minutes, P=.17), number of guides used (1.1 vs 1.2, P=.48), and femoral crossover rates (0% vs 0%) were similar between the 2 respective groups. A 7F sheathless approach to TRA-PCI results in no more IMT and early or late RA trauma than a standard 6F sheath/guide combination, rendering the 7F sheathless technique an attractive option for complex TRA-PCI. Copyright © 2017 Elsevier Inc. All rights reserved.
Mori, Yasuhisa; Itoi, Takao; Baron, Todd H; Takada, Tadahiro; Strasberg, Steven M; Pitt, Henry A; Ukai, Tomohiko; Shikata, Satoru; Noguchi, Yoshinori; Teoh, Anthony Yuen Bun; Kim, Myung-Hwan; Asbun, Horacio J; Endo, Itaru; Yokoe, Masamichi; Miura, Fumihiko; Okamoto, Kohji; Suzuki, Kenji; Umezawa, Akiko; Iwashita, Yukio; Hibi, Taizo; Wakabayashi, Go; Han, Ho-Seong; Yoon, Yoo-Seok; Choi, In-Seok; Hwang, Tsann-Long; Chen, Miin-Fu; Garden, O James; Singh, Harjit; Liau, Kui-Hin; Huang, Wayne Shih-Wei; Gouma, Dirk J; Belli, Giulio; Dervenis, Christos; de Santibañes, Eduardo; Giménez, Mariano Eduardo; Windsor, John A; Lau, Wan Yee; Cherqui, Daniel; Jagannath, Palepu; Supe, Avinash Nivritti; Liu, Keng-Hao; Su, Cheng-Hsi; Deziel, Daniel J; Chen, Xiao-Ping; Fan, Sheung Tat; Ker, Chen-Guo; Jonas, Eduard; Padbury, Robert; Mukai, Shuntaro; Honda, Goro; Sugioka, Atsushi; Asai, Koji; Higuchi, Ryota; Wada, Keita; Yoshida, Masahiro; Mayumi, Toshihiko; Hirata, Koichi; Sumiyama, Yoshinobu; Inui, Kazuo; Yamamoto, Masakazu
2018-01-01
Since the publication of the Tokyo Guidelines in 2007 and their revision in 2013, appropriate management for acute cholecystitis has been more clearly established. Since the last revision, several manuscripts, especially for alternative endoscopic techniques, have been reported; therefore, additional evaluation and refinement of the 2013 Guidelines is required. We describe a standard drainage method for surgically high-risk patients with acute cholecystitis and the latest developed endoscopic gallbladder drainage techniques described in the updated Tokyo Guidelines 2018 (TG18). Our study confirmed that percutaneous transhepatic gallbladder drainage should be considered the first alternative to surgical intervention in surgically high-risk patients with acute cholecystitis. Also, endoscopic transpapillary gallbladder drainage or endoscopic ultrasound-guided gallbladder drainage can be considered in high-volume institutes by skilled endoscopists. In the endoscopic transpapillary approach, either endoscopic naso-gallbladder drainage or gallbladder stenting can be considered for gallbladder drainage. We also introduce special techniques and the latest outcomes of endoscopic ultrasound-guided gallbladder drainage studies. Free full articles and mobile app of TG18 are available at: http://www.jshbps.jp/modules/en/index.php?content_id=47. Related clinical questions and references are also included. © 2017 Japanese Society of Hepato-Biliary-Pancreatic Surgery.
Rapid percutaneous nephrostomy catheter placement in neonates with the trocar technique.
Ozbek, O; Kaya, H E; Nayman, A; Saritas, T B; Guler, I; Koc, O; Karakus, H
2017-04-01
The purpose of this study was to assess the efficacy of a modified percutaneous nephrostomy procedure for grade III-IV hydronephrosis in neonates. Eleven neonates (five girls, six boys) with a mean age of 13.7days±9.9 (SD) (range, 4-28days) with pronounced hydronephrosis had percutaneous nephrostomy using a modified procedure. In all patients, percutaneous nephrostomy was performed with a trocar catheter under ultrasound guidance and then the catheter was placed into the collecting system without prior dilatation. Technical success was achieved in all patients. There were no major procedure-related complications. There was no perirenal hematoma on control ultrasound examinations and no hematuria was observed after the procedure. The median drainage time was 75days (range: 42-120days). Two children had urinary tract infection, which was controlled by using antibiotics. The trocar nephrostomy is a practical and feasible method, which can be used for neonates with grade III-IV hydronephrosis. Copyright © 2016 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.
Chae, In Hye; Kim, Eun-Kyung; Moon, Hee Jung; Yoon, Jung Hyun; Park, Vivian Y; Kwak, Jin Young
2017-07-01
To compare post-biopsy hematoma rates between ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy, and to investigate risk factors for post-biopsy hematoma. A total of 5304 thyroid nodules which underwent ultrasound guided biopsy were included in this retrospective study. We compared clinical and US features between patients with and without post-biopsy hematoma. Associations between these features and post-biopsy hematoma were analyzed. Post-biopsy hematoma rate was 0.8% (43/5121) for ultrasound guided-fine needle aspiration and 4.9% (9/183) for ultrasound guided-core needle biopsy (P < 0.001). For ultrasound guided-fine needle aspiration, gender, age, size, presence of vascularity, and suspicious US features were not associated with post-biopsy hematoma according to experience level. Post-biopsy hematoma occurred significantly more with ultrasound guided-core needle biopsy (9/179, 5.0%) than with ultrasound guided-fine needle aspiration (9/1138, 0.8%) (P < 0.001) in experienced performers and ultrasound guided-core needle biopsy was the only significant risk factor for post-biopsy hematoma (adjusted Odds Ratio, 6.458, P < 0.001). Post-biopsy hematoma occurred significantly more in ultrasound guided-core needle biopsy than in ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy was the only independent factor of post-biopsy hematoma in thyroid nodules.
Gruber, R; Bernt, R; Helbich, T H
2008-02-01
To analyze the cost-effectiveness of percutaneous image-guided CNBB (stereotactic-/ultrasound-guided; large/vacuum-assisted) of non-palpable breast lesions vs. OSB and to compare and discuss the results reported in the literature with results for German-speaking countries. A key word search in three databases, limited to the period from 1/1994 to 12/2006 was performed. Only original papers were selected. No published articles for German-speaking countries were identified; therefore a comprehensive data collection was made. On the basis of 377 abstracts, nine studies were evaluated for final assessment. The data of German-speaking countries were compared with results reported in the literature. This study demonstrates that CNBB compared to OSB leads to reduction in cost ranging from 51-96 %. The cost reduction depends on biopsy modality and lesion type and is subject to national fluctuations. CNBB can replace a surgical procedure in 71-85 % of cases. Use of CNBB as an alternative to OSB has the potential to substantially reduce healthcare costs. The data are based almost exclusively on the North American literature. A potential cost reduction in the Netherlands and Switzerland confirms these findings. Future work must include cost evaluation studies for German-speaking countries since this is an issue with important national economic ramifications.
Accuracy assessment of fluoroscopy-transesophageal echocardiography registration
NASA Astrophysics Data System (ADS)
Lang, Pencilla; Seslija, Petar; Bainbridge, Daniel; Guiraudon, Gerard M.; Jones, Doug L.; Chu, Michael W.; Holdsworth, David W.; Peters, Terry M.
2011-03-01
This study assesses the accuracy of a new transesophageal (TEE) ultrasound (US) fluoroscopy registration technique designed to guide percutaneous aortic valve replacement. In this minimally invasive procedure, a valve is inserted into the aortic annulus via a catheter. Navigation and positioning of the valve is guided primarily by intra-operative fluoroscopy. Poor anatomical visualization of the aortic root region can result in incorrect positioning, leading to heart valve embolization, obstruction of the coronary ostia and acute kidney injury. The use of TEE US images to augment intra-operative fluoroscopy provides significant improvements to image-guidance. Registration is achieved using an image-based TEE probe tracking technique and US calibration. TEE probe tracking is accomplished using a single-perspective pose estimation algorithm. Pose estimation from a single image allows registration to be achieved using only images collected in standard OR workflow. Accuracy of this registration technique is assessed using three models: a point target phantom, a cadaveric porcine heart with implanted fiducials, and in-vivo porcine images. Results demonstrate that registration can be achieved with an RMS error of less than 1.5mm, which is within the clinical accuracy requirements of 5mm. US-fluoroscopy registration based on single-perspective pose estimation demonstrates promise as a method for providing guidance to percutaneous aortic valve replacement procedures. Future work will focus on real-time implementation and a visualization system that can be used in the operating room.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mauri, Giovanni, E-mail: vanni.mauri@gmail.com; Cova, Luca; Ierace, Tiziana
2016-07-15
PurposeTo assess the effectiveness of percutaneous laser ablation (PLA) of cervical lymph node metastases from papillary thyroid carcinoma.Materials and Methods24 patients (62.3 ± 13.2 year; range 32–80) previously treated with thyroidectomy, neck dissection, and radioiodine ablation underwent ultrasound-guided PLA of 46 {sup 18}FDG-PET/CT—positive metachronous nodal metastases. All patients were at high surgical risk or refused surgery and were unsuitable for additional radioiodine ablation. A 300 µm quartz fiber and a continuous-wave Nd-YAG laser operating at 1.064 mm were used. Technical success, rate of complications, rate of serological conversion, and local control at follow-up were derived. Fisher’s exact test and Mann–Whitney U test were used andmore » Kaplan–Meier curve calculated.ResultsTechnical success was obtained in all 46 lymph nodes (100 %). There were no major complications. Thyroglobulin levels decreased from 8.40 ± 9.25 ng/ml before treatment to 2.73 ± 4.0 ng/ml after treatment (p = 0.011), with serological conversion in 11/24 (45.8 %) patients. Overall, local control was obtained in 40/46 (86.9 %) lymph nodes over 30 ± 11 month follow-up, with no residual disease seen at imaging in 19/24 (79.1 %) patients. Local control was achieved in 40/46 (86.9 %) lymph nodes at 1 year and in all of the 25 nodes (100 %) followed for 3 years. Estimated mean time to progression was 38.6 ± 2.7 m.ConclusionUltrasound-guided PLA is a feasible, safe, and effective therapy for the treatment of cervical lymph node metastases from papillary thyroid carcinoma.« less
Kyriakides, Rena; Jones, Patrick; Geraghty, Robert; Skolarikos, Andreas; Liatsikos, Evangellos; Traxer, Olivier; Pietropaolo, Amelia; Somani, Bhaskar K
2018-05-01
Music is a practical, inexpensive and harmless analgesic and anxiolytic. An increasing number of original studies have been performed to investigate its potential application in urology. Our aim was to identify the effect of music on outpatient based urological procedures. We systematically reviewed the effect of using music during all reported outpatient urology procedures, including transrectal ultrasound guided prostate biopsy, shock wave lithotripsy, urodynamic studies, percutaneous nephrostomy tube placement and cystoscopy. Data were included on all randomized trials from 1980 to 2017 and no language restrictions were applied. Included in analysis were 16 randomized studies in which 972 of 1,950 patients (49.8%) were exposed to music during an outpatient procedure. The procedures included transrectal ultrasound guided prostate biopsy in 4 studies in a total of 286 patients, shock wave lithotripsy in 6 studies in a total of 1,023, cystoscopy in 3 studies in a total of 331, urodynamics in 2 studies in a total of 210 and percutaneous nephrostomy in 1 study in a total of 100. All studies incorporated a visual analog score to measure pain. Anxiety was measured by STAI (State-Trait Anxiety Inventory) in 13 studies and by a visual analog scale in 2. While 14 of the 16 studies showed a reduction in self-reported pain, a reduction in anxiety was seen in 14. When using music, overall procedural satisfaction was better in 9 studies and patient willingness to repeat the procedure was also higher in 7. Our meta-analysis revealed a significant reduction in visual analog scale and STAI findings across all studies (p <0.001). Our systematic review demonstrated a beneficial effect of music on urological outpatient procedures. Music seemed to decrease anxiety and pain. It might serve as a useful adjunct to increase procedural satisfaction and patient willingness to undergo the procedure again. Copyright © 2018 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
MR-guided Focused Ultrasound for Uterine Fibroids
... Professions Site Index A-Z MR-guided Focused Ultrasound for Uterine Fibroids Magnetic Resonance-guided Focused Ultrasound ( ... are the limitations of MRgFUS? What is Focused Ultrasound of Uterine Fibroids? Magnetic Resonance-guided Focused Ultrasound ( ...
Microwave coagulation therapy and drug injection to treat splenic injury.
Zhang, Guoming; Sun, Yuanyuan; Yu, Jie; Dong, Lei; Mu, Nannan; Liu, Xiaohong; Liu, Lanfen; Zhang, Yan; Wang, Xiaofei; Liang, Ping
2014-01-01
The present study compares the efficacy of 915- and 2450-MHz contrast-enhanced ultrasound (CEUS)-guided percutaneous microwave coagulation with that of CEUS-guided thrombin injection for the treatment of trauma-induced spleen hemorrhage. In a canine splenic artery hemorrhage model with two levels of arterial diameter (A, <1 mm and B, between 1 and 2 mm), hemostatic therapy was performed using 915- and 2450-MHz microwaves and drug injection. Therapy efficacy was measured by comparing bleeding rate, hemostatic time, bleeding index, bleeding volume, and pathology. The most efficient technique was CEUS-guided 915-MHz percutaneous microwave coagulation therapy in terms of action time and total blood loss. The success rate of the 915-MHz microwave group was higher than that of the 2450-MHz microwave and the drug injection groups (except A level, P < 0.05). Hemostatic time, bleeding index, and bleeding volume were significantly less in the 915-MHz microwave group than those in the 2450-MHz microwave and drug injection groups (P < 0.05). Obvious degeneration and necrosis of parenchyma and large intravascular thrombosis were observed in the cavity of larger vessels in the 915-MHz microwave group, but pathologic changes of light injury could be seen in the other groups. The present study provides evidence that microwave coagulation therapy is more efficient than thrombin injection for the treatment of splenic hemorrhage. Furthermore, treatment with 915-MHz microwaves stops bleeding more rapidly and generates a wider cauterization zone than does treatment with 2450-MHz microwaves. Copyright © 2014 Elsevier Inc. All rights reserved.
Sninsky, Brian C; Sehgal, Priyanka D; Hinshaw, J Louis; McDermott, John C; Nakada, Stephen Y
2014-07-01
We evaluated the efficacy of ureteroscopic therapy (electrohydraulic lithotripsy [EHL] and intraductal laser lithotripsy [ILL]) in patients with challenging biliary stones secondary to anatomic variations resulting from a previous surgical procedure, including liver transplantation. A retrospective chart review was performed for all patients with previous surgical alteration of the gastrointestinal (GI) tract who underwent EHL or ILL via peroral or percutaneous access for choledocholithiasis by a single surgeon at our institution from 2000 to 2012. A database containing clinical and surgical variables was created, and long-term follow-up was conducted (3-138 months; median, 99 months). Thirteen patients (51.7±20.0 years; M:F, 10:3) in whom endoscopic retrograde cholangiopancreatography (ERCP), percutaneous transhepatic cholangiography (PTHC), or both failed were identified. Failure of ERCP/PTHC was because of inaccessibility of the calculi in all cases. Stone clearance was achieved in 12/13 (93%) patients; 8/12 (62%) after one procedure, and 4/12 (31%) after two procedures. One patient with biliary cast syndrome needed four interventions over 9 years. Major complications were low, with only one patient with hypotension and cholangitis that resolved with 24 hours of administration of intravenous fluids and antibiotics. Both endoscopic and percutaneous lithotripsies are effective treatments for refractory biliary calculi resulting from the post-surgical GI tract. Although a staged second procedure may be necessary in patients with significant stone burden, this is significantly better than extensive open surgery.
Biliary Ascariasis: MR Cholangiography Findings in Two Cases
Hwang, Cheol Mok; Ha, Hyun Kwon; Kim, Pyo Nyun; Lee, Moon-Gyu
2001-01-01
We describe the imaging features of two cases of biliary ascariasis. Ultrasonography and CT showed no specific abnormal findings, but MR cholangiography clearly demonstrated an intraductal linear filling defect that led to the correct diagnosis. MR cholangiography is thus a useful technique for the diagnosis of biliary ascariasis. PMID:11752990
A new technique of laparoscopic cholangiography.
Hagan, K D; Rosemurgy, A S; Albrink, M H; Carey, L C
1992-04-01
With the advent and rapid proliferation of laparoscopic cholecystectomy, numerous techniques and "tips" have been described. Intraoperative cholangiography during laparoscopic cholecystectomy can be tedious, frustrating, and time consuming. Described herein is a technique of intraoperative cholangiography during laparoscopic cholecystectomy which has proven to be easy, fast, and succinct. This method utilizes a rigid cholangiogram catheter which is placed into the peritoneal cavity through a small additional puncture site. This catheter is easily inserted into the cystic duct by extracorporeal manipulation. We suggest this method to surgeons who have shared our prior frustration with intraoperative cholangiography.
Lee, Vivian S; Krinsky, Glenn A; Nazzaro, Carol A; Chang, Jerry S; Babb, James S; Lin, Jennifer C; Morgan, Glyn R; Teperman, Lewis W
2004-12-01
To compare three-dimensional (3D) mangafodipir trisodium-enhanced T1-weighted magnetic resonance (MR) cholangiography with conventional T2-weighted MR cholangiography for depiction and definition of intrahepatic biliary anatomy in liver transplant donor candidates. One hundred eight healthy liver transplant donor candidates were examined with two MR cholangiographic methods. All candidates gave written informed consent, and the study was approved by the institutional review board. First, breath-hold transverse and coronal half-Fourier single-shot turbo spin-echo and breath-hold oblique coronal heavily T2-weighted turbo spin-echo sequences were performed. Second, mangafodipir trisodium-enhanced breath-hold fat-suppressed 3D gradient-echo sequences were performed through the ducts (oblique coronal plane) and through the entire liver (transverse plane). Interpretation of biliary anatomy findings, particularly variants affecting right liver lobe biliary drainage, and degree of interpretation confidence at both 3D mangafodipir trisodium-enhanced MR cholangiography and T2-weighted MR cholangiography were recorded and compared by using the Wilcoxon signed rank test. Then, consensus interpretations of both MR image sets together were performed. Intraoperative cholangiography was the reference-standard examination for 51 subjects who underwent right lobe hepatectomy. The McNemar test was used to compare the accuracies of the individual MR techniques with that of the consensus interpretation of both image sets together and to compare each technique with intraoperative cholangiography. Biliary anatomy was visualized with mangafodipir trisodium enhancement in all patients. Mangafodipir trisodium-enhanced image findings agreed with findings seen at combined interpretations significantly more often than did T2-weighted image findings (in 107 [99%] vs 88 [82%] of 108 donor candidates, P < .001). Confidence was significantly higher with the mangafodipir trisodium-enhanced images than with the T2-weighted images (mean confidence score, 4.5 vs 3.4; P < .001). In the 51 candidates who underwent intraoperative cholangiography, mangafodipir trisodium-enhanced imaging correctly depicted the biliary anatomy more often than did T2-weighted imaging (in 47 [92%] vs 43 [84%] donor candidates, P = .14), whereas the two MR imaging techniques combined correctly depicted the anatomy in 48 (94%) candidates. Mangafodipir trisodium-enhanced 3D MR cholangiography depicts intrahepatic biliary anatomy, especially right duct variants, more accurately than does conventional T2-weighted MR cholangiography. (c) RSNA, 2004.
Hilar cholangiocarcinoma: diagnosis, treatment options, and management
Soares, Kevin C.; Kamel, Ihab; Cosgrove, David P.; Herman, Joseph M.
2014-01-01
Hilar cholangiocarcinoma (HC) is a rare disease with a poor prognosis which typically presents in the 6th decade of life. Of the 3,000 cases seen annually in the United States, less than one half of these tumors are resectable. A variety of risk factors have been associated with HC, most notably primary sclerosing cholangitis (PSC), biliary stone disease and parasitic liver disease. Patients typically present with abdominal pain, pruritis, weight loss, and jaundice. Computed topography (CT), magnetic resonance imaging (MRI), and ultrasound (US) are used to characterize biliary lesions. Endoscopic retrograde cholangiopancreatography (ERCP) and percutaneous transhepatic cholangiography (PTC) assess local ductal extent of the tumor while allowing for therapeutic biliary drainage. MRCP has demonstrated similar efficacies to PTC and ERCP in identifying anatomic extension of tumors with less complications. Treatment consists of surgery, radiation, chemotherapy and photodynamic therapy. Biliary drainage of the future liver remnant should be performed to decrease bilirubin levels thereby facilitating future liver hypertrophy. Standard therapy consists of surgical margin-negative (R0) resection with extrahepatic bile duct resection, hepatectomy and en bloc lymphadenectomy. Local resection should not be undertaken. Lymph node invasion, tumor grade and negative margins are important prognostic indicators. In instances where curative resection is not possible, liver transplantation has demonstrated acceptable outcomes in highly selected patients. Despite the limited data, chemotherapy is indicated for patients with unresectable tumors and adequate functional status. Five-year survival after surgical resection of HC ranges from 10% to 40% however, recurrence can be as high as 50-70% even after R0 resection. Due to the complexity of this disease, a multi-disciplinary approach with multimodal treatment is recommended for this complex disease. PMID:24696835
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tamura, Akio, E-mail: a.akahane@gmail.com; Kato, Kenichi, E-mail: kkato@iwate-med.ac.jp; Suzuki, Michiko, E-mail: mamimichiko@me.com
PurposeThe purpose of this study was to assess the technical success rate and adverse events (AEs) associated with computed tomography (CT)-guided percutaneous gastrostomy for patients with head and neck cancer (HNC).Materials and MethodsThis retrospective study included patients with HNC who had undergone CT-guided percutaneous gastrostomy between February 2007 and December 2013. Information regarding the patients’ backgrounds, CT-guided percutaneous gastrostomy techniques, technical success rate, and AEs were obtained from the medical records. In all patients, the stomach was punctured under CT fluoroscopy with a Funada gastropexy device.ResultsDuring the study period, 177 patients underwent CT-guided percutaneous gastrostomy. The most common tumor locationmore » was the oral cavity, followed by the pharynx and maxilla. The indication for CT-guided percutaneous gastrostomy were tumor obstruction in 78 patients, postoperative dysphagia in 55 patients, radiation edema in 43 patients, and cerebral infarction in 1 patient. The technical success rate was 97.7 %. The overall mean procedure time was 25.3 min. Major AEs occurred in seven patients (4.0 %), including bleeding (n = 4), colonic injury (n = 1), gastric tear (n = 1), and aspiration pneumonia (n = 1). Minor AEs occurred in 15 patients (8.5 %), which included peristomal leakage (n = 6), irritation (n = 4), inadvertent removal (n = 2), peristomal hemorrhage (n = 1), peristomal infection (n = 1), and wound granulation (n = 1). The mean follow-up period was 111 days (range 1–1106 days).ConclusionOur study suggests that CT-guided gastrostomy may be suitable in patients with HNC.« less
Single-Institution Results of Image-Guided Nonplugged Percutaneous Versus Transjugular Liver Biopsy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hardman, Rulon L., E-mail: hardmanr@uthscsa.edu; Perrich, Kiley D.; Silas, Anne M.
2011-04-15
Purpose: To retrospectively review patients who underwent transjugular and image-guided percutaneous biopsy and compare the relative risk of ascites, thrombocytopenia, and coagulopathy. Materials and Methods: From August 2001 through February 2006, a total of 238 liver biopsies were performed. The radiologist reviewed all patient referrals for transjugular biopsy. These patients either underwent transjugular biopsy or were reassigned to percutaneous biopsy (crossover group). Patients referred to percutaneous image-guided liver biopsy underwent this same procedure. Biopsies were considered successful if a tissue diagnosis could be made from the samples obtained. Results: A total of 36 transjugular biopsies were performed with 3 totalmore » (8.3%) and 1 major (2.8%) complications. A total of 171 percutaneous biopsies were performed with 10 (5.8%) total and 3 (1.8%) major complications. The crossover group showed a total of 4 (12.9%) complications with 1 (3.2%) major complication. Sample adequacy was 91.9% for transjugular and 99.5% for percutaneous biopsy. Conclusion: Both transjugular and percutaneous liver biopsy techniques are efficacious and safe. Contraindications such as thrombocytopenia, coagulopathy, and ascites are indicators of greater complications but are not necessarily prevented by transjugular biopsy. Percutaneous biopsy more frequently yields a diagnostic specimen than transjugular biopsy.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tewari, Sanjit O., E-mail: tewaris@mskcc.org; Petre, Elena N., E-mail: petree@mskcc.org; Osborne, Joseph, E-mail: osbornej@mskcc.org
2013-12-15
A 68-year-old female with colorectal cancer developed a metachronous isolated fluorodeoxyglucose-avid (FDG-avid) segment 5/6 gallbladder fossa hepatic lesion and was referred for percutaneous ablation. Pre-procedure computed tomography (CT) images demonstrated a distended gallbladder abutting the segment 5/6 hepatic metastasis. In order to perform ablation with clear margins and avoid direct puncture and aspiration of the gallbladder, cholecystokinin was administered intravenously to stimulate gallbladder contraction before hydrodissection. Subsequently, the lesion was ablated successfully with sufficient margins, of greater than 1.0 cm, using microwave with ultrasound and FDG PET/CT guidance. The patient tolerated the procedure very well and was discharged home themore » next day.« less
Rehmani, Razia; Endo, Yoshimi; Bauman, Phillip; Hamilton, William; Potter, Hollis; Adler, Ronald
2015-10-01
Altered biomechanics from repetitive microtrauma, such as long practice hours in en pointe (tip of the toes) or demi pointe (balls of the feet) predispose ballet dancers to a multitude of musculoskeletal pathologies particularly in the lower extremities. Both ultrasound and magnetic resonance imaging (MRI) are radiation-sparing modalities which can be used to confidently evaluate these injuries, with ultrasound (US) offering the added utility of therapeutic intervention at the same time in experienced hands. The purposes of this paper were: (1) to illustrate the US and MRI features of lower extremity injury patterns in ballet dancers, focusing on pathologies commonly encountered at a single orthopedic hospital; (2) to present complementary roles of both ultrasound and MRI in the evaluation of these injuries whenever possible; (3) to review and present our institutional approach towards therapeutic ultrasound-guided interventions by presenting explicit cases. Online searches were performed using the search criteria of "ballet biomechanics" and "ballet injuries." The results were then further narrowed down by limiting articles published in the past 15 years, modality (US and MRI), anatomical region (foot and ankle, hip and knee) and to major radiology, orthopedics, and sports medicine journals. Performing ballet poses major stress to lower extremities and predisposes dancer to several musculoskeletal injuries. These can be adequately evaluated by both US and MRI. US is useful for evaluating superficial structures such as soft tissues, tendons, and ligaments, particularly in the foot and ankle. MRI provides superior resolution of deeper structures such as joints, bone marrow, and cartilage. In addition, US can be used as a therapeutic tool for providing quick symptomatic improvement in these athletes for who "time is money". Performing ballet may cause major stress to the lower extremities, predominantly affecting the foot and ankle, followed by the knee and hip. US and MRI play complementary roles in evaluating various orthopedic conditions in ballet dancers, with US allowing for dynamic evaluation and guidance for interventions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nasser, Felipe; Rocha, Rafael Dahmer, E-mail: rafaeldrocha@gmail.com; Falsarella, Priscila Mina
PurposeTo report a novel modified occlusion balloon technique to treat biliary leaks.MethodsA 22-year-old female patient underwent liver transplantation with biliary-enteric anastomosis. She developed thrombosis of the common hepatic artery and extensive ischemia in the left hepatic lobe. Resection of segments II and III was performed and a biliary-cutaneous leak originating at the resection plane was identified in the early postoperative period. Initial treatment with percutaneous transhepatic drainage was unsuccessful. Therefore, an angioplasty balloon was coaxially inserted within the biliary drain and positioned close to the leak.ResultsThe fistula output abruptly decreased after the procedure and stopped on the 7th day. Atmore » the 3-week follow-up, cholangiography revealed complete resolution of the leakage.ConclusionThis novel modified occlusion balloon technique was effective and safe. However, greater experience and more cases are necessary to validate the technique.« less
[A case of hemorrhagic cholecystitis associated with Churg-Strauss syndrome].
Koizumi, Satomi; Kamisawa, Terumi; Kuruma, Sawako; Chiba, Kazuro; Tabata, Taku; Koizumi, Koichi; Kurata, Masanao; Horiguchi, Shinichiro; Hishima, Tsunekazu
2016-01-01
A woman in her 70s with Churg-Strauss syndrome presented with epigastric pain. She was being treated with steroids at the time of admission. Computed tomography showed swelling of the gallbladder, and percutaneous transhepatic cholangiography revealed bloody secretion. On duodenoscopy, bleeding was observed from the orifice of the major duodenal papilla. Emergency cholecystectomy was performed under a diagnosis of hemorrhagic cholecystitis;intraoperatively, extensive hematoma was detected in the thickened wall of the gallbladder. Subsequent histopathological examination revealed mucosal ulceration with infiltration of inflammatory cells, torn small vessels, and extensive transmural bleeding and abscess formation in the thickened wall of the gallbladder. We considered that the hemorrhagic cholecystitis was induced by either vasculitis or corticosteroid therapy. To the best of our knowledge, this is the first report of hemorrhagic cholecystitis associated with Churg-Strauss syndrome.
Gu, Si-Ping; Zeng, Guo-Hua; You, Zhi-Yuan; Lu, Yi-Jin; Huang, Yun-Teng; Wang, Qing-Mao; He, Zhao-Hui
2015-12-01
Strict selection of patients for minimally invasive percutaneous nephrolithotomy could effectively improve the success rate of surgery. This study aimed to understand the required skills and the efficacy of mini-PCNL in the treatment of five types of upper ureteral calculi. Data collected after X-ray analysis and B mode ultrasound from 633 patients with upper ureteral and renal pelvis calculi who underwent B ultrasound-guided lithotomy was reviewed, including the following: type I, upper ureteral or renal pelvis calculi with moderate hydronephrosis (154 cases); type II, upper ureteral or renal pelvis calculi with severe hydronephrosis (157 cases); type III, upper ureteral or renal pelvis calculi without hydronephrosis (61 cases); type IV, renal pelvis calculi, one or two renal calyx calculi (206 cases); and type V, renal staghorn calculi (55 cases). Operations on 611 cases were successful. The treatment method for five patients was converted to open surgery. Twelve cases were treated by indwelling double-J tube retro-catheterization and extracorporeal shock wave lithotripsy. Five patients gave up the treatment. The rate of calculus clearance was 82.3 %, and the rate of residual calculus was 17.6 %. Selective renal artery embolization was performed in nine cases. Hydropneumothorax occurred in nine cases. No intestinal fistula occurred, and no patient had to undergo nephrectomy. The difficulty and the curative effect of the operation were different because the types of calculi varied. Selection of the procedure based on the different types of calculi could effectively improve the success rate of the procedure, reduce complications, and shorten the learning curve.
Lee, Seung Yul; Shin, Dong Ho; Kim, Jung Sun; Kim, Byeong Keuk; Ko, Young Guk; Choi, Donghoon; Jang, Yangsoo; Hong, Myeong Ki
2017-03-01
To evaluate the effects of sex and anthropometry on clinical outcomes in patients who underwent percutaneous coronary intervention (PCI). From three randomized trials (REal Safety and Efficacy of 3-month dual antiplatelet Therapy following Endeavor zotarolimus-eluting stent implantation, Impact of intraVascular UltraSound guidance on outcomes of Xience Prime stents in Long lesions, Chronic Total Occlusion InterVention with drUg-eluting Stents), we compared 333 pairs of men and women matched by propensity scores, all of whom underwent intravascular ultrasound (IVUS)-guided PCI for complex lesions. For 12 months, the incidence of adverse cardiac events, defined as the composite of cardiac death, target lesion-related myocardial infarction, and target lesion revascularization, was not different between women and men (2.4% vs. 2.4%, p=0.939). Using multivariable Cox's regression analysis, post-intervention minimum lumen area [MLA; hazard ratio (HR)=0.620, 95% confidence interval (CI)=0.423-0.909, p=0.014] by IVUS was a predictor of adverse cardiac events. Height on anthropometry and lesions with chronic total occlusion were significantly related to post-intervention MLA. However, female sex was not independently associated with post-intervention MLA. In an age and sex-adjusted model, patients in the low tertile of height exhibited a greater risk for adverse cardiac events than those in the high tertile of height (HR=6.391, 95% CI=1.160-35.206, p=0.033). Sex does not affect clinical outcomes after PCI for complex lesions. PCI outcomes, however, may be adversely affected by height.
Evaluation of percutaneous ethanol injections in benign thyroid nodules.
Perez, Camila Luhm Silva; Fighera, Tayane Muniz; Miasaki, Fabiola; Mesa Junior, Cleo Otaviano; Paz Filho, Gilberto Jorge da; Graf, Hans; Carvalho, Gisah Amaral de
2014-12-01
The objective of this study was to evaluate the efficacy and safety of percutaneous ethanol injection (PEI) in the treatment of benign thyroid nodules. We evaluated 120 patients with benign thyroid nodules. Patients underwent evaluation of serum TSH and free T4, cervical ultrasound, and thyroid scintigraphy (in those with suppressed TSH levels). The application of sterile ethanol 99% was guided by ultrasound, with the injected volume amounting to one-third of the nodule volume. Response was considered complete (reduction of 90%); partial (reduction between 50 and 90%); or none (reduction of < 50%). Autonomous nodules were evaluated for normalization of TSH levels. Among the nodules studied, 30.8% were solid, 56.7% were mixed, 12.5% were cystic, and 21.6% were hyperfunctioning. The initial volume of the treated nodules ranged from 0.9 to 74.8 mL (mean 13.1 ± 12.4 mL). We performed 1-8 sessions of PEI, applying an average of 6.2 mL of ethanol for patient. After 2 years of follow-up, 17% of patients achieved a complete response (94% reduction); 53%, a partial response (70% reduction); and 30%, no response. A reduction in the volume of autonomous nodules was noted in 70% of cases, and 54% had a normalized value of TSH. The main side effect is local pain, lasting less than 24 hours in most cases. This study showed that PEI is a safe and effective procedure for treatment of benign, solid or mixed thyroid nodules. Most cases resulted in significant reduction in nodule volume, with normalization of thyroid function.
[Nonsurgical therapy of abdominal and retroperitoneal abscesses].
Reuss, J A; Seitz, K
1987-06-01
From 1976 to March 1987 intraabdominal or retroperitoneal abscesses were confirmed by ultrasound in 40 patients. 13 patients had surgical drainage with zero-mortality. 3 of 27 patients were treated with antibiotics (only systemically). 24 patients were treated by percutaneous catheter drainage or needle aspiration. Elective cholecystectomy was performed later in 3 patients. Nonsurgical treatment was successful in 22/27 cases. 3 patients died despite percutaneous drainage. Failure of percutaneous drainage required surgical intervention in 3 patients. The considerably poorer primary condition of the patients receiving nonsurgical treatment allows no comparison with the surgical group. Advantages of percutaneous drainage and needle aspiration are a high success rate and low mortality. These techniques can be used even in critically ill persons.
Ultrasound diagnosis and percutaneous treatment of Achilles tendon tethering: a case series.
He, Lulu; Genin, Jason; Delzell, Patricia
2016-09-01
The purpose of this article is to report 3 cases of Kager's fat pad scarring and tethering to the deep surface of the Achilles tendon in patients with Achilles tendinosis symptomatology. The 3 patients were diagnosed sonographically by the use of a dynamic maneuver we described and named the "Kager's squeeze" technique. The key finding for diagnosis is the deformation and bowing of the deep fibers of the Achilles tendon during dynamic squeezing of Kager's fat pad. After diagnosis, the patients were treated with ultrasound-guided hydrodissection and scar release to restore normal motion between Kager's fat pad and the Achilles tendon. All 3 patients experienced significant clinical improvement shortly after treatment. Therefore, we suspect that Kager's fat pad scarring with Achilles tendon tethering may mimic or exacerbate Achilles tendinosis symptomatology and should be considered a possible diagnosis when conservative treatments for Achilles tendinosis fail. We demonstrate that Kager's fat pad scarring with Achilles tendon tethering can be diagnosed and treated with a simple in-office hydrodissection technique, leading to improved patient outcomes.
Seng, Chusheng; Mohan, P Chandra; Koh, Suang Bee Joyce; Howe, Tet Sen; Lim, Yee Gen; Lee, Brian P; Morrey, Bernard F
2016-02-01
A previously published study found positive outcomes for a novel technique for ultrasound-guided percutaneous ultrasonic tenotomy, showing good tolerability, safety, and early efficacy within an office setting. In this follow-up study, all 20 members of the original cohort were contacted after 3 years to explore the sustainability of symptomatic relief, functional improvement, and sonographic soft tissue response for percutaneous ultrasonic tenotomy. Case series; Level of evidence, 4. All 20 subjects of the clinical trial that was performed from June to November 2011 were further assessed at 36 months after the procedure in terms of visual analog scale for pain, Disabilities of the Arm, Shoulder and Hand (DASH)-Compulsory/Work scores, need for adjunct procedures, and overall satisfaction. Importantly, all 20 were reassessed with ultrasound imaging at 36 months, and evidence of the common extensor tendon response was assessed in terms of tendon hypervascularity, tendon thickness, and the progress of the hypoechoic scar tissue. A 100% clinical follow-up was achieved, inclusive of ultrasonographic assessment. None of the subjects required further treatment procedures, and 100% expressed satisfaction. Previous improvements in visual analog scale (current median ± SD, 0 ± 0.9; range, 0-3) and DASH-Work scores (current median, 0 ± 0) were sustained with conformity to a linear pattern on polynomial measures. There was further reduction in DASH-Compulsory scores to a median of 0 ± 0.644 (range, 0-2) with a significant decrease on repeated measures (P = .008). Tendon hypervascularity was resolved in 94% of patients, and 100% had reduction in tendon thickness. Overall reduction in the hypoechoic scar tissue was observed in all subjects, with a 90% response achieved by 6 months. Between 6 and 36 months, further reduction in the scar was observed in around 60% of patients, with 20% of patients having complete resolution of the hypoechoic scar. Minimally invasive percutaneous ultrasonic tenotomy provided sustained pain relief and functional improvement for recalcitrant tennis elbow at 3-year follow-up. It is one of the few procedures to demonstrate positive sonographic evidence of tissue-healing response and is an attractive alternative to surgical intervention for definitive treatment of recalcitrant elbow tendinopathy. © 2015 The Author(s).
Regöly-Mérei, J; Ihász, M; Szeberin, Z; Záborszky, A
Sixty-nine ultrasound-guided interventions (23 punctures and 46 drainages) were performed on 51 patients with the suspicion of intraabdominal abscess or another type of fluid collection in a prospective-controlled study. Of the procedures, 58.8% were carried out following surgery, while in 41.2% the indication were not related to prior surgical intervention. Repeated procedures were done in 10 patients. In the group of punctures the procedure was therapeutic in 3 cases and diagnostic in 16 patients. The drainage was technically successful in 92.7%. The drain was displaced or blocked in 27% (n = 10), but reinterventions were necessary in only 5 cases for this reason. The total number of redrainages was 18.9%. The percutaneous (pc) drainage was insufficient in 8 patients (21.6%), all these patients were operated on. 62.2% of the patients recovered after pc drainage, 13.5% following redrainage (total 75.5%). In 8.1% of the cases after pc drainage and in 5.4% after pc redrainage open surgery became necessary. There was only one complication due to the procedure. Seven patients (14.3%) died of the disease which indicated the procedure. There were no fatal outcomes on the account of the intervention. Ultrasound-guided puncture is a suitable method to indicate or contraindicate open surgery in the case of intraabdominal fluid collection. The diagnostic puncture may be followed by sonographically guided drainage or in selected cases by therapeutic puncture, but if the pc drainage is insufficient, open surgery should be performed in time.
Kuang, Y; Hilgers, A; Sadiq, M; Cochran, S; Corner, G; Huang, Z
2016-07-01
Clear needle visualisation is recognised as an unmet need for ultrasound guided percutaneous needle procedures including regional anaesthesia and tissue biopsy. With inadequate needle visibility, these procedures may result in serious complications or a failed operation. This paper reports analysis of the modal behaviour of a previously proposed ultrasound-actuated needle configuration, which may overcome this problem by improving needle visibility in colour Doppler imaging. It uses a piezoelectric transducer to actuate longitudinal resonant modes in needles (outer diameter 0.8-1.2mm, length>65mm). The factors that affect the needle's vibration mode are identified, including the needle length, the transducer's resonance frequency and the gripping position. Their effects are investigated using finite element modelling, with the conclusions validated experimentally. The actuated needle was inserted into porcine tissue up to 30mm depth and its visibility was observed under colour Doppler imaging. The piezoelectric transducer is able to generate longitudinal vibration with peak-to-peak amplitude up to 4μm at the needle tip with an actuating voltage of 20Vpp. Actuated in longitudinal vibration modes (distal mode at 27.6kHz and transducer mode at 42.2kHz) with a drive amplitude of 12-14Vpp, a 120mm needle is delineated as a coloured line in colour Doppler images, with both needle tip and shaft visualised. The improved needle visibility is maintained while the needle is advanced into the tissue, thus allowing tracking of the needle position in real time. Moreover, the needle tip is highlighted by strong coloured artefacts around the actuated needle generated by its flexural vibration. A limitation of the technique is that the transducer mode requires needles of specific lengths so that the needle's resonance frequency matches the transducer. This may restrict the choice of needle lengths in clinical applications. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.
Percutaneous puncture of renal calyxes guided by a novel device coupled with ultrasound
Chan, Chen Jen; Srougi, Victor; Tanno, Fabio Yoshiaki; Jordão, Ricardo Duarte; Srougi, Miguel
2015-01-01
ABSTRACT Purpose: To evaluate the efficiency of a novel device coupled with ultrassound for renal percutaneous puncture. Materials and Methods: After establishing hydronephrosis, ten pigs had three calyxes of each kidney punctured by the same urology resident, with and without the new device (“Punctiometer”). Time for procedure completion, number of attempts to reach the calyx, puncture precision and puncture complications were recorded in both groups and compared. Results: Puncture success on the first attempt was achieved in 25 punctures (83%) with the Punctiometer and in 13 punctures (43%) without the Punctiometer (p=0.011). The mean time required to perform three punctures in each kidney was 14.5 minutes with the Punctiometer and 22.4 minutes without the Punctiometer (p=0.025). The only complications noted were renal hematomas. In the Punctiometer group, all kidneys had small hematomas. In the no Punctiometer group 80% had small hematomas, 10% had a medium hematoma and 10% had a big hematoma. There was no difference in complications between both groups. Conclusions: The Punctiometer is an effective device to increase the likelihood of an accurate renal calyx puncture during PCNL, with a shorter time required to perform the procedure. PMID:26689521
NASA Astrophysics Data System (ADS)
Schmitt, Joseph M.; Adler, Desmond; Xu, Chenyang
Since the first coronary angioplasty was performed in the late 1970s, imaging has played a central role in percutaneous coronary intervention (PCI). Today more than three million PCI procedures are performed worldwide to expand narrowed arteries and to clear blood clots that can cause debilitating symptoms of myocardial ischemia or fatal heart attacks. Although X-ray angiography is still the workhorse imaging modality in the field of interventional cardiology, intravascular imaging has become an indispensable tool for guiding complex PCI procedures. Intravascular ultrasound (IVUS) and optical coherence tomography (OCT) are the two most commonly used catheter-based imaging technologies in coronary procedures. Since the first commercial intravascular OCT systems were introduced in Japan and the European Union in 2004 and in the United States in 2009, the application of intravascular OCT has grown rapidly [3, 15, 16].
Imaging for percutaneous renal access and management of renal calculi.
Park, Sangtae; Pearle, Margaret S
2006-08-01
Percutaneous renal stone surgery requires detailed imaging to define stone burden and delineate the anatomy of the kidney and nearby organs. It is also essential to carry out safe percutaneous access and to assess postoperative outcomes. The emergence of CT as the imaging modality of choice for detecting renal calculi and the ability of CT urography with or without three-dimensional reconstruction to delineate the collecting system makes this the most versatile and sensitive imaging modality for pre- and postoperative evaluation. At present, intravenous urogram continues to play an important role in the evaluation of patients considered for percutaneous nephrostolithotomy. Fluoroscopy re-mains the mainstay of intraoperative imaging, although ultrasound is a useful alternative. Selection and application of appropriate imaging modalities for patients undergoing per-cutaneous nephrostolithotomy enhances the safety and success of the procedure.
MDCT-Guided Transthoracic Needle Aspiration Biopsy of the Lung Using the Transscapular Approach
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rossi, Umberto G., E-mail: urossi76@hotmail.com; Seitun, Sara; Ferro, Carlo
2011-02-15
The purpose of this study is to report our preliminary experience using MDCT-guided percutaneous transthoracic needle aspiration biopsy using the transscapular approach in the upper posterolateral lung nodules, an area that it is difficult or hazardous to reach with the conventional approach. Five patients underwent CT-guided percutaneous transthoracic needle aspiration biopsy of the lung via the transscapular approach. A coaxial needle technique was used in all patients. Biopsy was successful in all patients. No major complications were encountered. One patient developed a minimal pneumothorax next to the lesion immediately after biopsy, which resolved spontaneously. MDCT-guided percutaneous transthoracic needle aspiration biopsymore » of the lung via the transscapular approach is an effective and safe procedure that reduces the risk of pneumothorax in selected patients.« less
Diederich, S; Padge, B; Vossas, U; Hake, R; Eidt, S
2006-01-01
Purpose: To assess feasibility, results and complications in image-guided biopsies using a single needle design in various organs. Materials and methods: 100 consecutive percutaneous biopsies were performed in 54 females and 46 males aged 24–87 years (mean age/standard deviation: 64.5 +/− 12 years) using a full-core end-cut tri-axial full-automatic biopsy needle (18 gauge BioPince ™, InterV-MDTech, Gainesville, Florida) under CT (n=45) or ultrasound (n=55) guidance. In 63 biopsies a coaxial technique was used. Results: Biopsies were obtained of liver (n=32), lymph nodes (n=17), thyroid (n=11), lung (n=9), adrenal (n=9), pelvis (n=6), chest wall/pleura (n=6), mediastinum (n=4), lytic bone lesions (n=2), retroperitoneum (n=1), muscle (n=1), pancreas (n=1), peritoneum (n=1). Between 1 and 6 (mean/SD 2.83 +/− 0.92) needle passes were performed. In 77 cases a malignant (40 metastases, 37 primary tumours) and in 23 a benign lesion was diagnosed. Of the 23 benign lesions a specific diagnosis was possible in 22. In one case necrosis and haemorrhage was diagnosed. In this patient surgery and autopsy both revealed a mediastinal haematoma of unknown origin. Eight minor complications (mild pain/local haematoma requiring no therapy) and three major complications (three pneumothoraces in nine lung biopsies requiring two aspirations and one drainage) were observed. There was no mortality. Conclusion: Percutaneous image-guided biopsy using the described full-core end-cut needle resulted in a specific diagnosis in 99/100 consecutive biopsies in various organs with a low complication rate. We use this needle type for all CT- or US-guided biopsies in all organs except for solid bone. PMID:16766268
DOE Office of Scientific and Technical Information (OSTI.GOV)
Welch, B. T., E-mail: Welch.brian@mayo.edu; Eiken, P. W.; Atwell, T. D.
PurposeMesothelioma has been considered a difficult pathologic diagnosis to achieve via image-guided core needle biopsy. The purpose of this study was to assess the diagnostic sensitivity of percutaneous image-guided biopsy for diagnosis of pleural mesothelioma.Materials and MethodsRetrospective review was performed to identify patients with a confirmed diagnosis of pleural mesothelioma and who underwent image-guided needle biopsy between January 1, 2002, and January 1, 2016. Thirty-two patients with pleural mesothelioma were identified and included for analysis in 33 image-guided biopsy procedures. Patient, procedural, and pathologic characteristics were recorded. Complications were characterized via standardized nomenclature [Common Terminology for Clinically Adverse Events (CTCAE)].ResultsPercutaneousmore » image-guided biopsy was associated with an overall sensitivity of 81%. No CTCAE clinically significant complications were observed. No image-guided procedures were complicated by pneumothorax or necessitated chest tube placement. No patients had tumor seeding of the biopsy tract.ConclusionPercutaneous image-guided biopsy can achieve high sensitivity for pathologic diagnosis of pleural mesothelioma with a low procedural complication rate, potentially obviating need for surgical biopsy.« less
Predicting Infected Bile Among Patients Undergoing Percutaneous Cholecystostomy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beardsley, Shannon L.; Shlansky-Goldberg, Richard D.; Patel, Aalpen
2005-04-15
Purpose. Patients may not achieve a clinical benefit after percutaneous cholecystostomy due to the inherent difficulty in identifying patients who truly have infected gallbladders. We attempted to identify imaging and biochemical parameters which would help to predict which patients have infected gallbladders. Methods. A retrospective review was performed of 52 patients undergoing percutaneous cholecystostomy for clinical suspicion of acute cholecystitis in whom bile culture results were available. Multiple imaging and biochemical variables were examined alone and in combination as predictors of infected bile, using logistic regression. Results. Of the 52 patients, 25 (48%) had infected bile. Organisms cultured included Enterococcus,more » Enterobacter, Klebsiella, Pseudomonas, E. coli, Citrobacter and Candida. No biochemical parameters were significantly predictive of infected bile; white blood cell count >15,000 was weakly associated with greater odds of infected bile (odds ratio 2.0, p = NS). The presence of gallstones, sludge, gallbladder wall thickening and pericholecystic fluid by ultrasound or CT were not predictive of infected bile, alone or in combination, although a trend was observed among patients with CT findings of acute cholecystitis toward a higher 30-day mortality. Radionuclide scans were performed in 31% of patients; all were positive and 66% of these patients had infected bile. Since no patient who underwent a radionuclide scan had a negative study, this variable could not be entered into the regression model due to collinearity. Conclusion. No single CT or ultrasound imaging variable was predictive of infected bile, and only a weak association of white blood cell count with infected bile was seen. No other biochemical parameters had any association with infected bile. The ability of radionuclide scanning to predict infected bile was higher than that of ultrasound or CT. This study illustrates the continued challenge to identify bacterial cholecystitis among patients referred for percutaneous cholecystostomy.« less
Transvaginal Drainage of Pelvic Abscesses and Collections Using Transabdominal Ultrasound Guidance.
Ching, Kevin C; Sumkin, Jules H
2015-01-01
Objectives. To evaluate clinical outcomes following transvaginal catheter placement using transabdominal ultrasound guidance for management of pelvic fluid collections. Methods. A retrospective review was performed for all patients who underwent transvaginal catheter drainage of pelvic fluid collections utilizing transabdominal ultrasound guidance between July 2008 and July 2013. 24 consecutive patients were identified and 24 catheters were placed. Results. The mean age of patients was 48.1 years (range = 27-76 y). 88% of collections were postoperative (n = 21), 8% were from pelvic inflammatory disease (n = 2), and 4% were idiopathic (n = 1). Of the 24 patients, 83% of patients (n = 20) had previously undergone a hysterectomy and 1 patient (4%) was pregnant at the time of drainage. The mean volume of initial drainage was 108 mL (range = 5 to 570). Catheters were left in place for an average of 4.3 days (range = 1-17 d). Microbial sampling was performed in all patients with 71% (n = 17) returning a positive culture. All collections were successfully managed percutaneously. There were no technical complications. Conclusions. Transvaginal catheter drainage of pelvic fluid collections using transabdominal ultrasound guidance is a safe and clinically effective procedure. Appropriate percutaneous management can avoid the need for surgery.
[Percutaneous radiofrequency ablation of hepatic metastases. Preliminary experience].
De Baere, T; Elias, D; Ducreux, M; Dromain, C; Kuach, V; Gamal El Din, M; Sobotka, A; Lasser, P; Roche, A
1999-11-01
To evaluate the efficiency of percutaneous radiofrequency ablation in the treatment of liver metastases. Eighteen patients with 31 liver metastases, mainly from colorectal cancer, 10 - 35 mm in diameter (m = 23), underwent 26 courses of percutaneous radiofrequency ablation. Fifteen patients had previously undergone hepatectomy, and 3 patients had contra-indications to surgery. Imaging guidance was ultrasound in 21 patients, CT in 4 (tumors not seen with ultrasound), and both in 1. A generator working at 450 KHz with a maximum output power of 150 W was used to treat each lesion for 18 - 20 min. Treatment was monitored with real time ultrasound. Among the 12 patients followed more than 3 months, only one of the 24 treated lesions recurred after a mean follow up of 259 ¿ 109 days. Liver disease was controlled in 8 of the 12 patients after 90 - 509 days (m = 306). Among these 8 patients, 3 were tumor free after 559, 378 and 90 days, respectively; 2 died tumor free of non-tumoral disease (pulmonary embolism, digestive bleeding); 3 developed lung metastases treated with chemotherapy (n = 2) or surgery (n = 1). Three of the 12 patients had widespread hepatic tumor occurrence, and one patient died of these metastases. Six patients experienced mild skin burns, but no major complication was observed. Radiofrequency ablation of hepatic metastases appears safe and promising in this preliminary experience. Further investigation is needed.
Chen, Yongchao; Zhu, Youzhi; Zhang, Yu; Zhang, Zixuan; Lian, Juan; Luo, Fucheng; Deng, Xuefei; Wong, Kelvin K L
2016-02-06
Double injection of blood into cisterna magna using a rabbit model results in cerebral vasospasm. An unacceptably high mortality rate tends to limit the application of model. Ultrasound guided puncture can provide real-time imaging guidance for operation. The aim of this paper is to establish a safe and effective rabbit model of cerebral vasospasm after subarachnoid hemorrhage with the assistance of ultrasound medical imaging. A total of 160 New Zealand white rabbits were randomly divided into four groups of 40 each: (1) manual control group, (2) manual model group, (3) ultrasound guided control group, and (4) ultrasound guided model group. The subarachnoid hemorrhage was intentionally caused by double injection of blood into their cisterna magna. Then, basilar artery diameters were measured using magnetic resonance angiography before modeling and 5 days after modeling. The depth of needle entering into cisterna magna was determined during the process of ultrasound guided puncture. The mortality rates in manual control group and model group were 15 and 23 %, respectively. No rabbits were sacrificed in those two ultrasound guided groups. We found that the mortality rate in ultrasound guided groups decreased significantly compared to manual groups. Compared with diameters before modeling, the basilar artery diameters after modeling were significantly lower in manual and ultrasound guided model groups. The vasospasm aggravated and the proportion of severe vasospasms was greater in ultrasound guided model group than that of manual group. In manual model group, no vasospasm was found in 8 % of rabbits. The ultrasound guided double injection of blood into cisterna magna is a safe and effective rabbit model for treatment of cerebral vasospasm.
Venturini, Massimo; Sallemi, Claudio; Colantoni, Caterina; Agostini, Giulia; Balzano, Gianpaolo; Esposito, Antonio; Secchi, Antonio; De Cobelli, Francesco; Falconi, Massimo; Piemonti, Lorenzo; Maffi, Paola; Del Maschio, Alessandro
2016-08-01
Islet allotransplantation is a less invasive alternative to surgical pancreas transplantation for Type 1 diabetes, while percutaneous intraportal islet autotransplantation (PIPIAT) is usually performed after pancreatic surgery to prevent diabetes. Our aim was to assess the feasibility, radiological aspects, complications and clinical outcome of PIPIAT following pancreatic surgery for not only chronic pancreatitis but also benign and malignant nodules. From 2008 to 2012, 41 patients were enrolled for PIPIAT 12-48 h after pancreatic surgery (extended pancreatic surgery for chronic pancreatitis and benign/malignant neoplasms). PIPIAT was performed using a combined ultrasonography and fluoroscopy-guided technique (4-F catheter). PIPIAT feasibility, median follow-up and metabolic (insulin independence rate, graft function based on C-peptide levels) and oncologic outcomes were recorded. PIPIAT was not performed in 7/41 patients (4 cases for an inadequate islet mass, 2 cases for haemodynamic instability and 1 case for islet culture contamination), while it was successfully performed in 34/34 patients. Procedure-related major complications occurred in four patients: two bleedings requiring transfusions, one patient with left portal vein thrombosis and one patient with sepsis. Median follow-up duration was 546 days. Insulin independence was achieved in 15/34 (44%) patients, partial graft function in 16/34 (47%) patients and no function in 3/34 (9%) patients. None of the 17 patients with malignant nodules developed liver metastases during follow-up. PIPIAT, performed under ultrasound and fluoroscopy combined guidance and not requiring immunosuppression, is feasible, with a relatively low complication rate and a better metabolic outcome than allotransplantation. PIPIAT can prevent pancreatogenic diabetes. Ultrasound is a useful tool for the guidance and monitoring of PIPIAT.
Lee, Seung-Yul; Shin, Dong-Ho; Kim, Jung-Sun; Kim, Byeong-Keuk; Ko, Young-Guk; Choi, Donghoon; Jang, Yangsoo
2017-01-01
Purpose To evaluate the effects of sex and anthropometry on clinical outcomes in patients who underwent percutaneous coronary intervention (PCI). Materials and Methods From three randomized trials (REal Safety and Efficacy of 3-month dual antiplatelet Therapy following Endeavor zotarolimus-eluting stent implantation, Impact of intraVascular UltraSound guidance on outcomes of Xience Prime stents in Long lesions, Chronic Total Occlusion InterVention with drUg-eluting Stents), we compared 333 pairs of men and women matched by propensity scores, all of whom underwent intravascular ultrasound (IVUS)-guided PCI for complex lesions. Results For 12 months, the incidence of adverse cardiac events, defined as the composite of cardiac death, target lesion–related myocardial infarction, and target lesion revascularization, was not different between women and men (2.4% vs. 2.4%, p=0.939). Using multivariable Cox's regression analysis, post-intervention minimum lumen area [MLA; hazard ratio (HR)=0.620, 95% confidence interval (CI)=0.423–0.909, p=0.014] by IVUS was a predictor of adverse cardiac events. Height on anthropometry and lesions with chronic total occlusion were significantly related to post-intervention MLA. However, female sex was not independently associated with post-intervention MLA. In an age and sex-adjusted model, patients in the low tertile of height exhibited a greater risk for adverse cardiac events than those in the high tertile of height (HR=6.391, 95% CI=1.160–35.206, p=0.033). Conclusion Sex does not affect clinical outcomes after PCI for complex lesions. PCI outcomes, however, may be adversely affected by height. PMID:28120559
Fleury, Eduardo de Faria Castro; Fleury, Jose Carlos Vendramini; Oliveira, Vilmar Marques de; Rinaldi, Jose Francisco; Piato, Sebastiao; Roveda Junior, Decio
2009-01-01
Proposal of systematization for the elastographic study in the ultrasound routine. Evaluation was made of 308 patients forwarded to the breast intervention service in the CTC-Genesis from May 1, 2007 to March 1, 2008 to perform percutaneous breast biopsy. Prior to the percutaneous biopsy, an ultrasound study and an elastography were performed. Lesions were primarily analyzed and classified according to the Bi-Rads lexicon criteria by the conventional ultrasound scan (B mode). The elastography was then performed and analyzed in accordance with the systematization proposed by the authors, using images obtained during compression and after decompression of the area of interest. Lesions were classified following the system developed by the authors using a four-point scale, where scores (1) and (2) were considered benign, score (3) probably benign and score (4) suspicion of malignancy. Results obtained by the two methods were compared with the histological results using the areas within the ROC (receiver operator curves) curves. The area within the curve for elastography was of 0.952 with a confidence interval between 0.910 and 0.966, error of 0.023, and of 0.867 with a confidence interval between 0.823 and 0.903, error of 0.0333 for the ultrasound. When the areas were compared, a difference between the curves of 0.026 was observed, which was statistically significant. This work shows the systematization of the elastographic study using information obtained during compression and after decompression of the ultrasound scan sample, thus showing that elastography might enhance the assessment of risk of malignancy for lesions characterized by the ultrasound.
Percutaneous management of urolithiasis during pregnancy.
Kavoussi, L R; Albala, D M; Basler, J W; Apte, S; Clayman, R V
1992-09-01
A total of 6 pregnant women with obstructing urinary calculi was managed by percutaneous nephrostomy drainage placed under ultrasound guidance with the patient under local anesthesia. All patients initially had relief of acute obstruction. However, occlusion of the percutaneous nephrostomy tubes with debris necessitated tube changes in 5 of 6 patients. In 2 patients recurrent nephrostomy tube obstruction, fever and pain led to percutaneous stone removal during pregnancy. In the remaining 4 patients the nephrostomy tubes were left indwelling through delivery. During the postpartum period 3 patients successfully underwent ureteroscopic stone extraction and 1 passed the stone spontaneously. Bacteriuria developed in each patient despite the use of preventive antibiotics. All 6 women had uncomplicated vaginal deliveries of healthy newborns and are currently asymptomatic with no evidence of obstruction. Percutaneous drainage of an acutely obstructed kidney in a pregnant woman is an effective temporizing alternative to ureteral stent placement until definitive treatment can be performed.
Pre-percutaneous nephrolithotomy opacification for caliceal diverticular calculi.
Matlaga, Brian R; Kim, Samuel C; Watkins, Stephanie L; Munch, Larry C; Chan, Brandon W; Lingeman, James E
2006-03-01
Caliceal diverticula harbor calculi in as many as 50% of cases. Such stones rarely pass spontaneously. Various stone-removal techniques have been used, with percutaneous techniques generally having the best results. In patients with nonradiopaque stones or in whom the diverticulum does not opacify when contrast is instilled retrograde or by intravenous urogram, contrast can be instilled directly into the cavity with CT or ultrasound guidance. Three such cases are described, with good results.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sheth, Rahul; Someshwar, Vimal; Warawdekar, Gireesh
2007-02-15
Purpose. We report our experience of the retrieval of intravascular foreign body objects by the percutaneous use of the Gemini Dormia basket. Methods. Over a period of 2 years we attempted the percutaneous removal of intravascular foreign bodies in 26 patients. Twenty-six foreign bodies were removed: 8 intravascular stents, 4 embolization coils, 9 guidewires, 1 pacemaker lead, and 4 catheter fragments. The percutaneous retrieval was achieved with a combination of guide catheters and the Gemini Dormia basket. Results. Percutaneous retrieval was successful in 25 of 26 patients (96.2%). It was possible to remove all the intravascular foreign bodies with amore » combination of guide catheters and the Dormia basket. No complication occurred during the procedure, and no long-term complications were registered during the follow-up period, which ranged from 6 months to 32 months (mean 22.4 months overall). Conclusion. Percutaneous retrieval is an effective and safe technique that should be the first choice for removal of an intravascular foreign body.« less
[Laparoscopic therapy of choledocholithiasis].
Rechner, J; Beller, S; Zerz, A; Szinicz, G
1996-01-01
The introduction of laparoscopic cholecystectomy has led to controversial discussions about the proceeding in case of coincident common bile duct stones. In our unit choledocholithiasis has been treated laparoscopically since November 1991. Basic requirement has been a routine intraoperative cholangiography. 67 patients with common bile duct stones were treated until January 1995. All patients underwent a follow up and the results were compared to other concepts. In 40 cases common bile duct stones were eliminated via cystic duct and in 27 cases by choledochotomy. The choledochus was drained routinely for postoperative x-ray control. In 9 cases we found residual concrements: 7 patients required postoperative endoscopic papillotomy and in 2 cases the calculi where eliminated with a dormia basket introduced via drainage tube. In one case surgical management was changed to laparotomy. Postoperative complications occurred in 8 cases. One patient suffering from bacterial peritonitis underwent laparotomy on the 9th postoperative day; one with bleeding from the cystic artery was treated by relaparoscopy. One patient developed a liver abscess and two patients a bilioma requiring ultrasound guided drainage. A superficial wound infection in one patient and a biliary leakage after removal of the drainage in two patients healed spontaneously. Due to an intact papilla with less stress to the patient, as well as a complication rate comparable with other published therapeutic concepts, this strategy can be recommended as a valuable alternative procedure.
Cubeddu, Roberto J; Babin, Ivan; Inglessis, Ignacio
2014-07-01
A percutaneous approach to the closure of patent ductus arteriosus (PDA) is the preferred procedure in the majority of cases. However, there is little experience with percutaneous closure of unusually large PDA. We report the case of a 28-year-old female with moderate left ventricular dilation and pulmonary hypertension resulting from a large 16 mm PDA. Percutaneous closure was successfully performed using an off-label Amplatzer muscular ventricular septal defect occluder after intravascular ultrasound assessment. Technical challenges, including accurate assessment of defect size and device selection are exemplified along with a comprehensive overview of the available literature.
Davies, Huw Ob; Popplewell, Matthew; Darvall, Katy; Bate, Gareth; Bradbury, Andrew W
2016-05-01
The last 10 years have seen the introduction into everyday clinical practice of a wide range of novel non-surgical treatments for varicose veins. In July 2013, the UK National Institute for Health and Care Excellence recommended the following treatment hierarchy for varicose veins: endothermal ablation, ultrasound-guided foam sclerotherapy, surgery and compression hosiery. The aim of this paper is to review the randomised controlled trials that have compared endothermal ablation and ultrasound-guided foam sclerotherapy to determine if the level 1 evidence base still supports an "endothermal ablation first" strategy for the treatment of varicose veins. A PubMed and OVID literature search (until 31 January 2015) was performed and randomised controlled trials comparing endothermal ablation and ultrasound-guided foam sclerotherapy were obtained. Although anatomical success appeared higher with endothermal ablation than ultrasound-guided foam sclerotherapy, clinical success and patient-reported outcomes measures were similar. Morbidity and complication rates were very low and not significantly different between endothermal ablation and ultrasound-guided foam sclerotherapy. Ultrasound-guided foam sclerotherapy was consistently less expensive that endothermal ablation. All endovenous modalities appear to be successful and have a role in modern day practice. Although further work is required to optimise ultrasound-guided foam sclerotherapy technique to maximise anatomical success and minimise retreatment, the present level 1 evidence base shows there is no significant difference in clinical important outcomes between ultrasound-guided foam sclerotherapy and endothermal ablation. As ultrasound-guided foam sclerotherapy is less expensive, it is likely to be a more cost-effective option in most patients in most healthcare settings. Strict adherence to the treatment hierarchy recommended by National Institute for Health and Care Excellence seems unjustified. © The Author(s) 2015.
Shirota, Ayumi; Nomura, Tetsuya; Kubota, Hiroshi; Taminishi, Shunta; Urata, Ryota; Sugimoto, Takeshi; Higuchi, Yusuke; Kato, Taku; Keira, Natsuya; Tatsumi, Tetsuya
2015-07-28
Because of the unusual anatomy of an anomalous origin of the right coronary artery from the left sinus of Valsalva, selective cannulation of the guiding catheter in percutaneous coronary intervention for these cases is always challenging. A 58-year-old Japanese man was admitted to our hospital complaining of worsening exertional chest pain. He was suspected of having unstable angina pectoris and underwent cardiac catheterization. We found a subtotal occlusive lesion in the mid-portion of his right coronary artery that originated from the left sinus of Valsalva. On the previous percutaneous coronary intervention, we failed to cannulate the guiding catheter to the anomalous orifice of the right coronary artery. Therefore, we decided to use the GuideLiner catheter for stable back-up support from the beginning. A 6Fr GuideLiner catheter was introduced into the right coronary artery by anchoring it coaxially with a semi-compliant balloon catheter. And we successfully deployed two drug-eluting stents by crossing over the posterior-descending artery. Final angiography demonstrated favorable dilatation of the target lesion, and native blood flow in the right coronary artery was completely recovered. GuideLiner is a monorail-type "child" support catheter that facilitates coaxial guiding catheter engagement and an appropriate back-up force, achieving successful device delivery to target lesions in this kind of complex percutaneous coronary intervention.
Double Guiding Catheters for Complex Percutaneous Coronary Intervention
Chou, Shing-Hsien; Lin, Chia-Pin; Lin, Yen-Chen; Kuo, Chi-Tai; Lin, Ming-Shyan; Chang, Chi-Jen
2012-01-01
A large-lumen guiding catheter is often used for complex percutaneous coronary intervention—particularly when a final kissing-balloon or 2-stent technique is required. However, catheter insertion is sometimes restricted by diseased vascular access sites or a tortuous vascular route. We report 2 cases in which a unique double guiding catheter technique was used to create a lumen of sufficient size for complex percutaneous coronary intervention. In each patient, two 6F guiding catheters were used concurrently to engage the ostium of 1 target vessel. In 1 patient, these catheters were used for the delivery of 2 balloons to complete kissing-balloon dilation after single-stent placement. In the other patient, the catheters were used to deliver 2 stents sequentially to their respective target lesions. The stents were then deployed simultaneously as kissing stents, followed by high-pressure kissing-balloon postdilation. PMID:22412243
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ellens, N; Partanen, A; Ghoshal, G
Purpose: Interstitial high intensity therapeutic ultrasound (HITU) applicators can be used to ablate tissue percutaneously, allowing for minimally-invasive treatment without ionizing radiation [1,2]. The purpose of this study was to evaluate the feasibility and usability of combining multielement interstitial HITU applicators with a clinical magnetic resonance imaging (MRI)-guided focused ultrasound software platform. Methods: The Sonalleve software platform (Philips Healthcare, Vantaa, Finland) combines anatomical MRI for target selection and multi-planar MRI thermometry to provide real-time temperature information. The MRI-compatible interstitial US applicators (Acoustic MedSystems, Savoy, IL, USA) had 1–4 cylindrical US elements, each 1 cm long with either 180° or 360°more » of active surface. Each applicator (4 Fr diameter, enclosed within a 13 Fr flexible catheter) was inserted into a tissue-mimicking agar-silica phantom. Degassed water was circulated around the transducers for cooling and coupling. Based on the location of the applicator, a virtual transducer overlay was added to the software to assist targeting and to allow automatic thermometry slice placement. The phantom was sonicated at 7 MHz for 5 minutes with 6–8 W of acoustic power for each element. MR thermometry data were collected during and after sonication. Results: Preliminary testing indicated that the applicator location could be identified in the planning images and the transducer locations predicted within 1 mm accuracy using the overlay. Ablation zones (thermal dose ≥ 240 CEM43) for 2 active, adjacent US elements ranged from 18 mm × 24 mm (width × length) to 25 mm × 25 mm for the 6 W and 8 W sonications, respectively. Conclusion: The combination of interstitial HITU applicators and this software platform holds promise for novel approaches in minimally-invasive MRI-guided therapy, especially when bony structures or air-filled cavities may preclude extracorporeal HIFU.[1] Diederich et al. IEEE UFFFC 46.5 (1999): 1218.[2] Chopra et al. PMB 50.21 (2005): 4957. Funding support was provided by Philips Healthcare and in-kind support from Acoustic MedSystems Inc. Ari Partanen is a paid employee of Philips Healthcare. Goutam Ghoshal and Everette Clif Burdette are paid employees of Acoustic MedSystems Inc.« less
Fluoroscopy guided percutaneous renal access in prone position
Sharma, Gyanendra R; Maheshwari, Pankaj N; Sharma, Anshu G; Maheshwari, Reeta P; Heda, Ritwik S; Maheshwari, Sakshi P
2015-01-01
Percutaneous nephrolithotomy is a very commonly done procedure for management of renal calculus disease. Establishing a good access is the first and probably the most crucial step of this procedure. A proper access is the gateway to success. However, this crucial step has the steepest learning curve for, in a fluoroscopy guided access, it involves visualizing a three dimensional anatomy on a two dimensional fluoroscopy screen. This review describes the anatomical basis of the renal access. It provides a literature review of all aspects of percutaneous renal access along with the advances that have taken place in this field over the years. The article describes a technique to determine the site of skin puncture, the angle and depth of puncture using a simple mathematical principle. It also reviews the common problems faced during the process of puncture and dilatation and describes the ways to overcome them. The aim of this article is to provide the reader a step by step guide for percutaneous renal access. PMID:25789297
Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid
... News Physician Resources Professions Site Index A-Z Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid ... Needle Aspiration Biopsy of the Thyroid? What is Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid? ...
... the patient. Because ultrasound images are captured in real-time, they can show the structure and movement of ... perform an ultrasound-guided biopsy . Because ultrasound provides real-time images, it is often used to guide biopsy ...
Melioidosis: A Rare Cause of Liver Abscess
Teh, Catherine S. C.; Casupang, Ma. Amornetta J.
2016-01-01
Case Presentation. This is a case of a 44-year-old male, farmer, known to be diabetic, presenting with two-week history of vague abdominal pain associated with high grade fever. Abdominal CT scan showed localized liver abscess at segment 8 measuring 7.5 × 6.8 × 6.1 cm. Patient subsequently underwent laparoscopic ultrasound guided pigtail insertion for drainage of abscess. Culture studies showed moderate growth of Burkholderia pseudomallei in which the patient completed seven days of IV Meropenem. On follow-up after 12 weeks of oral Sulfamethoxazole/Trimethoprim, taken twice a day, the patient remained asymptomatic with no residual findings based on the abdominal ultrasound. Discussion. Diagnosis of melioidosis, a known “great masquerader,” relies heavily on culture studies. Consensus with regard to the management of liver abscess caused by Burkholderia pseudomallei has not yet been established due to the rarity of cases. Surgical intervention through either a percutaneous or open drainage has shown good outcomes compared to IV antibiotics alone. In Philippines, the possibility of underreporting is highly plausible. This write-up serves not only to report a rare presentation of melioidosis but also to add to the number of cases reported in the country, possibly indicative of disease emergence. PMID:27529039
Melioidosis: A Rare Cause of Liver Abscess.
Martin, Peter Franz M San; Teh, Catherine S C; Casupang, Ma Amornetta J
2016-01-01
Case Presentation. This is a case of a 44-year-old male, farmer, known to be diabetic, presenting with two-week history of vague abdominal pain associated with high grade fever. Abdominal CT scan showed localized liver abscess at segment 8 measuring 7.5 × 6.8 × 6.1 cm. Patient subsequently underwent laparoscopic ultrasound guided pigtail insertion for drainage of abscess. Culture studies showed moderate growth of Burkholderia pseudomallei in which the patient completed seven days of IV Meropenem. On follow-up after 12 weeks of oral Sulfamethoxazole/Trimethoprim, taken twice a day, the patient remained asymptomatic with no residual findings based on the abdominal ultrasound. Discussion. Diagnosis of melioidosis, a known "great masquerader," relies heavily on culture studies. Consensus with regard to the management of liver abscess caused by Burkholderia pseudomallei has not yet been established due to the rarity of cases. Surgical intervention through either a percutaneous or open drainage has shown good outcomes compared to IV antibiotics alone. In Philippines, the possibility of underreporting is highly plausible. This write-up serves not only to report a rare presentation of melioidosis but also to add to the number of cases reported in the country, possibly indicative of disease emergence.
Tresley, Jonathan; Jose, Jean
2015-04-01
Osteoarthritis of the knee can be a debilitating and extremely painful condition. In patients who desire to postpone knee arthroplasty or in those who are not surgical candidates, percutaneous knee injection therapies have the potential to reduce pain and swelling, maintain joint mobility, and minimize disability. Published studies cite poor accuracy of intra-articular knee joint injections without imaging guidance. We present a sonographically guided posteromedial approach to intra-articular knee joint injections with 100% accuracy and no complications in a consecutive series of 67 patients undergoing subsequent computed tomographic or magnetic resonance arthrography. Although many other standard approaches are available, a posteromedial intra-articular technique is particularly useful in patients with a large body habitus and theoretically allows for simultaneous aspiration of Baker cysts with a single sterile preparation and without changing the patient's position. The posteromedial technique described in this paper is not compared or deemed superior to other standard approaches but, rather, is presented as a potentially safe and efficient alternative. © 2015 by the American Institute of Ultrasound in Medicine.
Al-Kawas, Firas; Aslanian, Harry; Baillie, John; Banovac, Filip; Buscaglia, Jonathan M; Buxbaum, James; Chak, Amitabh; Chong, Bradford; Coté, Gregory A; Draganov, Peter V; Dua, Kulwinder; Durkalski, Valerie; Elmunzer, B Joseph; Foster, Lydia D; Gardner, Timothy B; Geller, Brian S; Jamidar, Priya; Jamil, Laith H; Keswani, Rajesh N; Khashab, Mouen A; Lang, Gabriel D; Law, Ryan; Lichtenstein, David; Lo, Simon K; McCarthy, Sean; Melo, Silvio; Mullady, Daniel; Nieto, Jose; Bayne Selby, J; Singh, Vikesh K; Spitzer, Rebecca L; Strife, Brian; Tarnaksy, Paul; Taylor, Jason R; Tokar, Jeffrey; Wang, Andrew Y; Williams, April; Willingham, Field; Yachimski, Patrick
2018-02-14
The optimal approach to the drainage of malignant obstruction at the liver hilum remains uncertain. We aim to compare percutaneous transhepatic biliary drainage (PTBD) to endoscopic retrograde cholangiography (ERC) as the first intervention in patients with cholestasis due to suspected malignant hilar obstruction (MHO). The INTERCPT trial is a multi-center, comparative effectiveness, randomized, superiority trial of PTBD vs. ERC for decompression of suspected MHO. One hundred and eighty-four eligible patients across medical centers in the United States, who provide informed consent, will be randomly assigned in 1:1 fashion via a web-based electronic randomization system to either ERC or PTBD as the initial drainage and, if indicated, diagnostic procedure. All subsequent clinical interventions, including crossover to the alternative procedure, will be dictated by treating physicians per usual clinical care. Enrolled subjects will be assessed for successful biliary drainage (primary outcome measure), adequate tissue diagnosis, adverse events, the need for additional procedures, hospitalizations, and oncological outcomes over a 6-month follow-up period. Subjects, treating clinicians and outcome assessors will not be blinded. The INTERCPT trial is designed to determine whether PTBD or ERC is the better initial approach when managing a patient with suspected MHO, a common clinical dilemma that has never been investigated in a randomized trial. ClinicalTrials.gov, Identifier: NCT03172832 . Registered on 1 June 2017.
Tynan, Jennifer R; Schachar, Norman S; Marshall, Geoffrey B; Gray, Robin R
2005-02-01
Unicameral bone cysts of the pelvis are extremely rare. A 19-year old man presented with a pathologic fracture through a pelvic unicameral bone cyst. He was treated with computed tomography-guided percutaneous curettage, biopsy, and demineralized bone matrix injection. Treatment has proven successful in short-term follow-up.
Ultrasound-guided synovial biopsy
Sitt, Jacqueline C M; Wong, Priscilla
2016-01-01
Ultrasound-guided needle biopsy of synovium is an increasingly performed procedure with a high diagnostic yield. In this review, we discuss the normal synovium, as well as the indications, technique, tissue handling and clinical applications of ultrasound-guided synovial biopsy. PMID:26581578
Imbalzano, Egidio; Vatrano, Marco; Mandraffino, Giuseppe; Ghiadoni, Lorenzo; Gangemi, Sebastiano; Bruno, Rosa Maria; Ciconte, Vincenzo Antonio; Paunovic, Nevena; Costantino, Rossella; Mormina, Enrico Maria; Ceravolo, Roberto; Saitta, Antonino; Dattilo, Giuseppe
2015-12-01
Left ventricular ejection fraction (LVEF) and pulse wave velocity (PWV) are acknowledged as independent risk factors in different high-risk populations. We investigated the effects of arterial stiffness on LV function at 3 and 6 months after acute myocardial infarction. Changes in LVEF were evaluated in 136 consecutive patients who were diagnosed with ST-segment elevation coronary syndrome and treated with primary percutaneous coronary intervention. Doppler guided by 2D ultrasound was used to measure carotid-femoral PWV. According to tertiles of arterial stiffness, a significant correlation between higher PWV and worse recovery in LVEF was found (3 months EF change: 9.9 ± 5.0% vs 5.9 ± 3.4 vs 3.8 ± 1.6; p < 0.001 and 6 months EF change: 18.5 ± 7.0% vs 11.5 ± 5.2 vs 7.3 ± 3.0; p = 0.002). In the multivariate analysis PWV showed the ability to predict the outcome in terms of EF recovery at 3 and 6 months also after any correction for age and other variables (β = -0.566, p < 0.001). Arterial stiffening may result in a less effective recovery of LV function after acute myocardial infarction.
Vanderhoek, Matthew David; Hoang, Hieu T; Goff, Brandon
2013-09-01
Occipital neuralgia is a condition manifested by chronic occipital headaches and is thought to be caused by irritation or trauma to the greater occipital nerve (GON). Treatment for occipital neuralgia includes medications, nerve blocks, and pulsed radiofrequency ablation (PRFA). Landmark-guided GON blocks are the mainstay in both the diagnosis and treatment of occipital neuralgia. Ultrasound is being utilized more and more in the chronic pain clinic to guide needle advancement when performing procedures; however, there are no reports of ultrasound used to guide a diagnostic block or PRFA of the GON. We report two cases in which ultrasound was used to guide diagnostic greater occipital nerve blocks and greater occipital nerve pulsed radiofrequency ablation for treatment of occipital neuralgia. Two patients with occipital headaches are presented. In Case 1, ultrasound was used to guide diagnostic blocks of the greater occipital nerves. In Case 2, ultrasound was utilized to guide placement of radiofrequency probes for pulsed radiofrequency ablation of the greater occipital nerves. Both patients reported immediate, significant pain relief, with continued pain relief for several months. Further study is needed to examine any difference in outcomes or morbidity between the traditional landmark method versus ultrasound-guided blocks and pulsed radiofrequency ablation of the greater occipital nerves.
VanderHoek, Matthew David; Hoang, Hieu T; Goff, Brandon
2013-01-01
Occipital neuralgia is a condition manifested by chronic occipital headaches and is thought to be caused by irritation or trauma to the greater occipital nerve (GON). Treatment for occipital neuralgia includes medications, nerve blocks, and pulsed radiofrequency ablation (PRFA). Landmark-guided GON blocks are the mainstay in both the diagnosis and treatment of occipital neuralgia. Ultrasound is being utilized more and more in the chronic pain clinic to guide needle advancement when performing procedures; however, there are no reports of ultrasound used to guide a diagnostic block or PRFA of the GON. We report two cases in which ultrasound was used to guide diagnostic greater occipital nerve blocks and greater occipital nerve pulsed radiofrequency ablation for treatment of occipital neuralgia. Two patients with occipital headaches are presented. In Case 1, ultrasound was used to guide diagnostic blocks of the greater occipital nerves. In Case 2, ultrasound was utilized to guide placement of radiofrequency probes for pulsed radiofrequency ablation of the greater occipital nerves. Both patients reported immediate, significant pain relief, with continued pain relief for several months. Further study is needed to examine any difference in outcomes or morbidity between the traditional landmark method versus ultrasound-guided blocks and pulsed radiofrequency ablation of the greater occipital nerves. PMID:24282778
Bowel lesions: percutaneous US-guided 18-gauge needle biopsy--preliminary experience.
Tudor, G R; Rodgers, P M; West, K P
1999-08-01
Ultrasonography-guided percutaneous biopsy was performed with local anesthesia and an 18-gauge needle in 10 patients with bowel-wall lesions. All patients underwent clinical review within 1 month. Biopsy was diagnostic in all patients. There were no complications, and all patients tolerated the procedure well. The technique appears to be safe and had an excellent diagnostic yield in our series.
Clinical Utility and Pitfalls of Ultrasound Guided Foreign Body Removal in War Fighters
2015-12-01
1 AD_________________ AWARD NUMBER: W81XWH-08-2-0162 TITLE: Clinical Utility and Pitfalls of Ultrasound Guided Foreign Body Removal in War...Clinical Utility and Pitfalls of Ultrasound Guided Foreign Body Removal in War Fighters 5a. CONTRACT NUMBER 5b. GRANT NUMBER: W81XWH-08-2-0162 5c...Purpose: To demonstrate that 1) ultrasound guided foreign body removal (USFBR) is superior to conventional surgery in the cadaver model, 2) USFBR can be
O'Sullivan, Paul J; Gorman, Grainne M; Hardiman, Orla M; Farrell, Michael J; Logan, P Mark
2006-01-01
The purpose of this study was to evaluate the feasibility of sonographically guided percutaneous muscle biopsy in the investigation of neuromuscular disorders. Sonographically guided percutaneous needle biopsy of skeletal muscle was performed with a 14-gauge core biopsy system in 40 patients over a 24-month period. Patients were referred from the Department of Neurology under investigation for neuromuscular disorders. Sonography was used to find suitable tissue and to avoid major vascular structures. A local anesthetic was applied below skin only. A 3- to 4-mm incision was made. Three 14-gauge samples were obtained from each patient. All samples were placed on saline-dampened gauze and sent for neuropathologic analysis. As a control, we retrospectively assessed results of the 40 most recent muscle samples acquired via open surgical biopsy. With the use of sonography, 32 (80%) of 40 patients had a histologic diagnosis made via percutaneous needle biopsy. This included 26 (93%) of 28 patients with acute muscular disease and 6 (50%) of 12 patients with chronic disease. In the surgical group (all acute disease), 38 (95%) of 40 patients had diagnostic tissue attained. Sonographically guided percutaneous 14-gauge core skeletal muscle biopsy is a useful procedure, facilitating diagnosis in acute muscular disease. It provides results comparable with those of open surgical biopsy in acute muscular disease. It may also be used in chronic muscular disease but repeated or open biopsy may be needed.
Gedikoglu, Murat; Oguzkurt, Levent
2017-01-01
We aimed to describe ultrasonography (US)-guided percutaneous aspiration thrombectomy in pregnant women with iliofemoral deep vein thrombosis. This study included nine pregnant women with acute and subacute iliofemoral deep vein thrombosis, who were severe symptomatic cases with massive swelling and pain of the leg. Patients were excluded from the study if they had only femoropopliteal deep vein thrombosis or mild symptoms of deep vein thrombosis. US-guided percutaneous aspiration thrombectomy was applied to achieve thrombus removal and uninterrupted venous flow. The treatment was considered successful if there was adequate venous patency and symptomatic relief. Complete or significant thrombus removal and uninterrupted venous flow from the puncture site up to the iliac veins were achieved in all patients at first intervention. Complete relief of leg pain was achieved immediately in seven patients (77.8%). Two patients (22.2%) had a recurrence of thrombosis in the first week postintervention. One of them underwent a second intervention, where percutaneous aspiration thrombectomy was performed again with successful removal of thrombus and establishment of in line flow. Two patients were lost to follow-up after birth. None of the remaining seven patients had rethrombosis throughout the postpartum period. Symptomatic relief was detected clinically in these patients. Endovascular treatment with US-guided percutaneous aspiration thrombectomy can be considered as a safe and effective way to remove thrombus from the deep veins in pregnant women with acute and subacute iliofemoral deep vein thrombosis.
Gedikoglu, Murat; Oguzkurt, Levent
2017-01-01
PURPOSE We aimed to describe ultrasonography (US)-guided percutaneous aspiration thrombectomy in pregnant women with iliofemoral deep vein thrombosis. METHODS This study included nine pregnant women with acute and subacute iliofemoral deep vein thrombosis, who were severe symptomatic cases with massive swelling and pain of the leg. Patients were excluded from the study if they had only femoropopliteal deep vein thrombosis or mild symptoms of deep vein thrombosis. US-guided percutaneous aspiration thrombectomy was applied to achieve thrombus removal and uninterrupted venous flow. The treatment was considered successful if there was adequate venous patency and symptomatic relief. RESULTS Complete or significant thrombus removal and uninterrupted venous flow from the puncture site up to the iliac veins were achieved in all patients at first intervention. Complete relief of leg pain was achieved immediately in seven patients (77.8%). Two patients (22.2%) had a recurrence of thrombosis in the first week postintervention. One of them underwent a second intervention, where percutaneous aspiration thrombectomy was performed again with successful removal of thrombus and establishment of in line flow. Two patients were lost to follow-up after birth. None of the remaining seven patients had rethrombosis throughout the postpartum period. Symptomatic relief was detected clinically in these patients. CONCLUSION Endovascular treatment with US-guided percutaneous aspiration thrombectomy can be considered as a safe and effective way to remove thrombus from the deep veins in pregnant women with acute and subacute iliofemoral deep vein thrombosis. PMID:27801353
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rosenthall, L.; Fonseca, C.; Arzoumanian, A.
1979-03-01
Bile flow patterns were studied with serial /sup 99m/Tc-IDA images in 19 patients with cholecysto- and choledochointestinal anastomoses, gastroenteric bypasses, and combinations of the two. Complications such as anastomotic, afferent, and efferent loop obstruction and bile leakage were readily detected even in the presence of jaundice. This noninvasive technique warrants further investigation to determine its indications and weaknesses.
Jiang, Minghuan; You, Joyce Hs
2016-05-01
This study aimed to compare the clinical and economic outcomes of pharmacogenetic-guided (PG-guided) and platelet reactivity testing-guided antiplatelet therapy for patients with acute coronary syndrome undergoing percutaneous coronary intervention. A decision-analytic model was simulated including four antiplatelet strategies: universal clopidogrel 75 mg daily, universal alternative P2Y12 inhibitor (prasugrel or ticagrelor), PG-guided therapy, and platelet reactivity testing-guided therapy. PG-guided therapy was the preferred option with lowest cost (US$75,208) and highest quality-adjusted life years gained (7.6249 quality-adjusted life years). The base-case results were robust in sensitivity analysis. PG-guided antiplatelet therapy showed the highest probability to be preferred antiplatelet strategy for acute coronary syndrome patients with percutaneous coronary intervention.
De Palma, Giovanni D
2013-06-27
The rate of choledocholithiasis in patients with symptomatic cholelithiasis is estimated to be approximately 10%-33%, depending on the patient's age. Development of Endoscopic Retrograde Cholangiopancreatography and Laparoscopic Surgery and improvement of diagnostic procedures have influenced new approaches to the management of common bile duct stones in association with gallstones. At present available minimally-invasive treatments of cholecysto-choledocal lithiasis include: single-stage laparoscopic treatment, perioperative endoscopic treatment and endoscopic treatment alone. Published data evidence that, associated endoscopic-laparoscopic approach necessitates increased number of procedures per patient while single-stage laparoscopic treatment is associated with a shorter hospital stay. However, current data does not suggest clear superiority of any one approach with regard to success, mortality, morbidity and cost-effectiveness. Considering the variety of therapeutic options available for management, a critical appraisal and decision-making is required. Endoscopic retrograde cholangiopancreatography/EST should be adopted on a selective basis, i.e., in patients with acute obstructive suppurative cholangitis, severe biliary pancreatitis, ampullary stone impaction or severe comorbidity. In a setting where all facilities are available, decision in the selection of the therapeutic option depends on the patients, the number and size of choledocholithiasis stones, the anatomy of the cystic duct and common bile duct, the surgical history of patients and local expertise.
Characterization of optically actuated MRI-compatible active needles for medical interventions
NASA Astrophysics Data System (ADS)
Black, Richard J.; Ryu, Seokchang; Moslehi, Behzad; Costa, Joannes M.
2014-03-01
The development of a Magnetic Resonance Imaging (MRI) compatible optically-actuated active needle for guided percutaneous surgery and biopsy procedures is described. Electrically passive MRI-compatible actuation in the small diameter needle is provided by non-magnetic materials including a shape memory alloy (SMA) subject to precise fiber laser operation that can be from a remote (e.g., MRI control room) location. Characterization and optimization of the needle is facilitated using optical fiber Bragg grating (FBG) temperature sensors arrays. Active bending of the needle during insertion allows the needle to be accurately guided to even relatively small targets in an organ while avoiding obstacles and overcoming undesirable deviations away from the planned path due to unforeseen or unknowable tissue interactions. This feature makes the needle especially suitable for use in image-guided surgical procedures (ranging from MRI to CT and ultrasound) when accurate targeting is imperative for good treatment outcomes. Such interventions include reaching small tumors in biopsies, delineating freezing areas in, for example, cryosurgery and improving the accuracy of seed placement in brachytherapy. Particularly relevant are prostate procedures, which may be subject to pubic arch interference. Combining diagnostic imaging and actuation assisted biopsy into one treatment can obviate the need for a second exam for guided biopsy, shorten overall procedure times (thus increasing operating room efficiencies), address healthcare reimbursement constraints and, most importantly, improve patient comfort and clinical outcomes.
Lima, Estevao; Rodrigues, Pedro L; Mota, Paulo; Carvalho, Nuno; Dias, Emanuel; Correia-Pinto, Jorge; Autorino, Riccardo; Vilaça, João L
2017-10-01
Puncture of the renal collecting system represents a challenging step in percutaneous nephrolithotomy (PCNL). Limitations related to the use of standard fluoroscopic-based and ultrasound-based maneuvers have been recognized. To describe the technique and early clinical outcomes of a novel navigation system for percutaneous kidney access. This was a proof-of-concept study (IDEAL phase 1) conducted at a single academic center. Ten PCNL procedures were performed for patients with kidney stones. Flexible ureterorenoscopy was performed to determine the optimal renal calyx for access. An electromagnetic sensor was inserted through the working channel. Then the selected calyx was punctured with a needle with a sensor on the tip guided by real-time three-dimensional images observed on the monitor. The primary endpoints were the accuracy and clinical applicability of the system in clinical use. Secondary endpoints were the time to successful puncture, the number of attempts for successful puncture, and complications. Ten patients were enrolled in the study. The median age was 47.1 yr (30-63), median body mass index was 22.85kg/m 2 (19-28.3), and median stone size was 2.13cm (1.5-2.5cm). All stones were in the renal pelvis. The Guy's stone score was 1 in nine cases and 2 in one case. All 10 punctures of the collecting system were successfully completed at the first attempt without X-ray exposure. The median time to successful puncture starting from insertion of the needle was 20 s (range 15-35). No complications occurred. We describe the first clinical application of a novel navigation system using real-time electromagnetic sensors for percutaneous kidney access. This new technology overcomes the intrinsic limitations of traditional methods of kidney access, allowing safe, precise, fast, and effective puncture of the renal collecting system. We describe a new technology allowing safe and easy puncture of the kidney without radiation exposure. This could significantly facilitate one of the most challenging steps in percutaneous removal of kidney stones. Copyright © 2017 European Association of Urology. Published by Elsevier B.V. All rights reserved.
Petranovic, Milena; Gilman, Matthew D; Muniappan, Ashok; Hasserjian, Robert P; Digumarthy, Subba R; Muse, Victorine V; Sharma, Amita; Shepard, Jo-Anne O; Wu, Carol C
2015-10-01
The purpose of this study was to evaluate the diagnostic yield and accuracy of CT-guided percutaneous biopsy of anterior mediastinal masses and assess prebiopsy characteristics that may help to select patients with the highest diagnostic yield. Retrospective review of all CT-guided percutaneous biopsies of the anterior mediastinum conducted at our institution from January 2003 through December 2012 was performed to collect data regarding patient demographics, imaging characteristics of biopsied masses, presence of complications, and subsequent surgical intervention or medical treatment (or both). Cytology, core biopsy pathology, and surgical pathology results were recorded. A per-patient analysis was performed using two-tailed t test, Fisher's exact test, and Pearson chi-square test. The study cohort included 52 patients (32 men, 20 women; mean age, 49 years) with mean diameter of mediastinal mass of 6.9 cm. Diagnostic yield of CT-guided percutaneous biopsy was 77% (40/52), highest for thymic neoplasms (100% [11/11]). Non-diagnostic results were seen in 12 of 52 patients (23%), primarily in patients with lymphoma (75% [9/12]). Fine-needle aspiration yielded the correct diagnosis in 31 of 52 patients (60%), and core biopsy had a diagnostic rate of 77% (36/47). None of the core biopsies were discordant with surgical pathology. There was no statistically significant difference between the diagnostic and the nondiagnostic groups in patient age, lesion size, and presence of necrosis. The complication rate was 3.8% (2/52), all small self-resolving pneumothoraces. CT-guided percutaneous biopsy is a safe diagnostic procedure with high diagnostic yield (77%) for anterior mediastinal lesions, highest for thymic neoplasms (100%), and can potentially obviate more invasive procedures.
Pandit, Bhagya Narayan; Chaturvedi, Vivek; Parakh, Neeraj; Gade, Sandeep; Trehan, Vijay
2015-04-01
Treatment for superior vena cava syndrome (SVCS) by percutaneous interventions has become established as a definitive therapy. However, there is a significant risk of rupture during SVC intervention. We describe an uncommon case that developed SVC rupture during percutaneous intervention for idiopathic SVCS. This was managed successfully with pericardiocentesis and rapid implantation of covered stent in SVC by rapid guiding catheter swapping technique. This, however, led to inadvertent obstruction of left innominate vein which was successfully treated by kissing balloon inflation. At 18-month follow-up, he is asymptomatic with a well apposed patent stent-graft in the SVC.
Double Gallbladder Originating from Left Hepatic Duct: A Case Report and Review of Literature
Gorecki, Piotr J.; Andrei, Valeriu E; Musacchio, Tito
1998-01-01
Background: Double gallbladder is a rare anomaly of the biliary tract. Double gallbladder arising from the left hepatic duct was previously reported only once in the literature. Case Report: A case of symptomatic cholelithiasis in a double gallbladder, diagnosed on preoperative ultrasound, computed tomography (CT) and endoscopic retrograde cholangiopancreatogram (ERCP) is reported. At laparoscopic cholangiography via the accessory gallbladder no accessory cystic duct was visualized. After conversion to open cholecystectomy, the duplicated gallbladder was found to arise directly from the left hepatic duct; it was resected and the duct repaired. Conclusions: We emphasize that a careful intraoperative cholangiographic evaluation of the accessory gallbladder is mandatory in order to prevent inadvertent injury to bile ducts, since a large variety of ductal abnormality may exist. PMID:10036124
DOE Office of Scientific and Technical Information (OSTI.GOV)
Khalifa, Mohamed, E-mail: mkhalifa@nhs.net; Patel, Neeral R., E-mail: neeral.patel06@gmail.com; Moser, Steven, E-mail: steven.moser@imperial.nhs.uk
PurposeThe purpose of this technical note is to demonstrate the novel use of CT-guided superior vena cava (SVC) puncture and subsequent tunnelled haemodialysis (HD) line placement in end-stage renal failure (ESRF) patients with central venous obstruction refractory to conventional percutaneous venoplasty (PTV) and wire transgression, thereby allowing resumption of HD.MethodsThree successive ESRF patients underwent CT-guided SVC puncture with subsequent tract recanalisation. Ultrasound-guided puncture of the right internal jugular vein was performed, the needle advanced to the patent SVC under CT guidance, with subsequent insertion of a stabilisation guidewire. Following appropriate tract angioplasty, twin-tunnelled HD catheters were inserted and HD resumed.ResultsNomore » immediate complications were identified. There was resumption of HD in all three patients with a 100 % success rate. One patient’s HD catheter remained in use for 2 years post-procedure, and another remains functional 1 year to the present day. One patient died 2 weeks after the procedure due to pancreatitis-related abdominal sepsis unrelated to the Tesio lines.ConclusionCT-guided SVC puncture and tunnelled HD line insertion in HD-related central venous occlusion (CVO) refractory to conventional recanalisation options can be performed safely, requires no extra equipment and lies within the skill set and resources of most interventional radiology departments involved in the management of HD patients.« less
CT-Guided Percutaneous Biopsy of Intrathoracic Lesions
Lal, Hira; Nath, Alok; Borah, Samudra
2012-01-01
Percutaneous CT-guided needle biopsy of mediastinal and pulmonary lesions is a minimally invasive approach for obtaining tissue for histopathological examination. Although it is a widely accepted procedure with relatively few complications, precise planning and detailed knowledge of various aspects of the biopsy procedure is mandatory to avert complications. In this pictorial review, we reviewed important anatomical approaches, technical aspects of the procedure, and its associated complications. PMID:22438689
Percutaneous CT-Guided Treatment of Osteochondritis Dissecans of the Sacroiliac Joint
DOE Office of Scientific and Technical Information (OSTI.GOV)
Becce, Fabio, E-mail: fabio.becce@chuv.ch; Mouhsine, Elyazid; Mosimann, Pascal John
2012-08-15
Osteochondritis dissecans (OCD) is a joint disorder that affects the articular cartilage and subchondral bone, most commonly at the knee. OCD of the sacroiliac joint is extremely rare. Management of OCD remains controversial, and surgery is often needed, especially when conservative treatment fails. We present a rare case of OCD involving the left sacroiliac joint successfully treated by percutaneous computed tomography-guided retrograde drilling and debridement.
Endoscopic Management of Peri-Pancreatic Fluid Collections.
Yip, Hon Chi; Teoh, Anthony Yuen Bun
2017-09-15
In the past decade, there has been a progressive paradigm shift in the management of peri-pancreatic fluid collections after acute pancreatitis. Refinements in the definitions of fluid collections from the updated Atlanta classification have enabled better communication amongst physicians in an effort to formulate optimal treatments. Endoscopic ultrasound (EUS)-guided drainage of pancreatic pseudocysts has emerged as the procedure of choice over surgical cystogastrostomy. The approach provides similar success rates with low complications and better quality of life compared with surgery. However, an endoscopic "step up" approach in the management of pancreatic walled-off necrosis has also been advocated. Both endoscopic and percutaneous drainage routes may be used depending on the anatomical location of the collections. New-generation large diameter EUS-specific stent systems have also recently been described. The device allows precise and effective drainage of the collections and permits endoscopic necrosectomy through the stents.
Fine-needle aspiration cytology of intraductal papillary-mucinous tumors: a retrospective analysis.
Layfield, Lester J; Cramer, Harvey
2005-01-01
Intraductal papillary-mucinous tumor (IPMT) of the pancreas has become the accepted terminology for a group of mucin-producing epithelial proliferations lying within ectatic segments of the main pancreatic duct or its large branches. These neoplasms generally are associated with an indolent course, characteristic endoscopic ultrasonographic (EUS) findings, and a variable histo- and cytomorphology ranging from hyperplasia to carcinoma. Cytological specimens obtained by endoscopic ultrasound-guided or percutaneous fine-needle aspiration (FNA) are characterized by a background containing abundant mucin in which are entrapped single or loosely cohesive clusters of neoplastic cells characteristically showing a goblet-cell morphology. The degree of nuclear atypia, cell crowding, and cell shape varies between smears within a single case and between cases. Cytomorphological examination, when coupled with EUS features, is accurate for the diagnosis of these lesions but often it underdiagnoses the grade of the neoplasm. (c) 2005 Wiley-Liss, Inc.
Mechanical obstruction to ventilation from an ovarian cyst during pregnancy.
Beng, D T; Choon, L T
1991-05-01
This report documents the danger of the gravid uterus fixing a large ovarian cyst in a position disadvantageous to diaphragmatic excursion and thereby obstructing ventilation. A 34-year-old pregnant patient presented at 18 weeks amenorrhoea with a large ovarian cyst. She gave a history of exertional dyspnoea and orthopnoea. Clinical examination revealed a grossly enlarged abdomen and a respiratory rate of 28 breaths.min-1. Intraoperatively, ventilation was markedly impaired resulting in cyanosis and bradycardia. This was relieved by drainage of the ovarian cyst. A left lateral tilt with manual traction on the tumour may have avoided this problem. Should the above measures be inadequate, immediate drainage of the cyst is essential. Severe respiratory distress may require ultrasound-guided, percutaneous, aspiration of the cyst preoperatively. However, as in this patient, the absence of gross signs of respiratory failure does not preclude acute ventilatory failure after induction of anaesthesia.
Nishiguchi, S; Shiomi, S; Sasaki, N; Iwata, Y; Tanaka, H; Kubo, S; Hirohashi, K; Ochi, H
2000-10-01
A 39-year-old woman with acute cholecystitis and gallstones underwent laparoscopic cholecystectomy. She suffered from recurrent episodes of cholangitis due to injury of the major bile ducts during laparoscopic cholecystectomy. Hepatobiliary scintigraphy with Tc-99m Sn-N-pyridoxyl-5-methyltryptophan was performed. Although normal bile excretion was found from the left hepatic duct to the percutaneous transhepatic biliary drainage (PTBD) tube, excretion from the right hepatic lobe was prolonged. Scintigraphy with Tc-99m diethylenetriaminepentaacetic acid-galactosyl human serum albumin demonstrated atrophy of the right hepatic lobe and enlargement of the left hepatic lobe. Cholangiography via the PTBD tube revealed complete obstruction of the left hepatico-jejunal anastomosis and could not enhance the right intrahepatic bile duct. A right hepatic lobectomy was performed because of the atrophy, glissonitis and the absence of an appropriate bile duct for reconstruction. Postoperatively she was active and exhibited no evidence of recurrent cholangitis.
Ultrasound guided therapeutic injections of the cervical spine and brachial plexus.
Cormick, Wes
2014-02-01
Introduction : Recent applications in ultrasound imaging include ultrasound assessment and ultrasound guided therapeutic injections of the spine and brachial plexus. Discussion : Ultrasound is an ideal modality for these regions as it allows accurate safe and quick injection of single or multiple sites. It has the added advantages of lack of ionising radiation, and can be done without requiring large expensive radiology equipment. Conclusion : Brachial plexus pathology may be present in patients presenting for shoulder symptoms where very little is found at imaging the shoulder. It is important to understand the anatomy and normal variants that may exist to be able to recognise when pathology is present. When pathology is demonstrated it is easy to do a trial of therapy with ultrasound guided injection of steroid around the nerve lesion. This review will outline the normal anatomy and variants and common pathology, which can be amenable to ultrasound guided injection of steroid.
Systemic Air Embolism After CT-guided Lung Biopsy
2017-11-27
Patients Who Underwent Percutaneous Lung Biopsy Under CT Guidance; Patients Who Presented Systemic Air Embolism After Percutaneous Lung Biopsy Under CT Guidance Depicted at the Time of the Procedure on a Whole Thoracic CT
Clinical outcomes of a percutaneous cholecystostomy for acute cholecystitis: a multicentre analysis
Sanjay, Pandanaboyana; Mittapalli, Devender; Marioud, Aseel; White, Richard D; Ram, Rishi; Alijani, Afshin
2013-01-01
Background The aim of this study was to review a series of consecutive percutaneous cholecystostomies (PC) to analyse the clinical outcomes. Methods All patients who underwent a PC between 2000 and 2010 were reviewed retrospectively for indications, complications, and short- and long-term outcomes. Results Fifty-three patients underwent a PC with a median age was 74 years (range 14–93). 92.4% (n = 49) of patients were American Society of Anesthesiologists (ASA) III and IV. 82% (43/53) had ultrasound-guided drainage whereas 18% (10/53) had computed tomography (CT)-guided drainage. 71.6% (n = 38) of PC's employed a transhepatic route and 28.4% (n = 15) transabdominal route. 13% (7/53) of patients developed complications including bile leaks (n = 5), haemorrhage (n = 1) and a duodenal fistula (n = 1). All bile leaks were noted with transabdominal access (5 versus 0, P = 0.001). 18/53 of patients underwent a cholecystectomy of 4/18 was done on the index admission. 6/18 cholecystectomies (33%) underwent a laparoscopic cholecystectomy and the remaining required conversion to an open cholecystectomy (67%). 13/53 (22%) patients were readmitted with recurrent cholecystitis during follow-up of which 7 (54%) had a repeated PC. 12/53 patients died on the index admission. The overall 1-year mortality was 37.7% (20/53). Conclusions Only a small fraction of patients undergoing a PC proceed to a cholecystectomy with a high risk of conversion to an open procedure. A quarter of patients presented with recurrent cholecystitis during follow-up. The mortality rate is high during the index admission from sepsis and within the 1 year of follow-up from other causes. PMID:23750493
Clinical outcomes of a percutaneous cholecystostomy for acute cholecystitis: a multicentre analysis.
Sanjay, Pandanaboyana; Mittapalli, Devender; Marioud, Aseel; White, Richard D; Ram, Rishi; Alijani, Afshin
2013-07-01
The aim of this study was to review a series of consecutive percutaneous cholecystostomies (PC) to analyse the clinical outcomes. All patients who underwent a PC between 2000 and 2010 were reviewed retrospectively for indications, complications, and short- and long-term outcomes. Fifty-three patients underwent a PC with a median age was 74 years (range 14-93). 92.4% (n = 49) of patients were American Society of Anesthesiologists (ASA) III and IV. 82% (43/53) had ultrasound-guided drainage whereas 18% (10/53) had computed tomography (CT)-guided drainage. 71.6% (n = 38) of PC's employed a transhepatic route and 28.4% (n = 15) transabdominal route. 13% (7/53) of patients developed complications including bile leaks (n = 5), haemorrhage (n = 1) and a duodenal fistula (n = 1). All bile leaks were noted with transabdominal access (5 versus 0, P = 0.001). 18/53 of patients underwent a cholecystectomy of 4/18 was done on the index admission. 6/18 cholecystectomies (33%) underwent a laparoscopic cholecystectomy and the remaining required conversion to an open cholecystectomy (67%). 13/53 (22%) patients were readmitted with recurrent cholecystitis during follow-up of which 7 (54%) had a repeated PC. 12/53 patients died on the index admission. The overall 1-year mortality was 37.7% (20/53). Only a small fraction of patients undergoing a PC proceed to a cholecystectomy with a high risk of conversion to an open procedure. A quarter of patients presented with recurrent cholecystitis during follow-up. The mortality rate is high during the index admission from sepsis and within the 1 year of follow-up from other causes. © 2012 International Hepato-Pancreato-Biliary Association.
Image-guided percutaneous cryotherapy for the management of gynecologic cancer metastases.
Solomon, Leigh A; Munkarah, Adnan R; Vorugu, Vinaya R; Deppe, Gunter; Adam, Barbara; Malone, John M; Littrup, Peter J
2008-11-01
To report the clinical response to image-guided percutaneous cryotherapy (IPC) for the palliative management of localized metastases in patients with gynecologic malignancies. Institutional review board approval and patient consent were obtained. Gynecologic oncology patients were identified from our institution's cryotherapy database from August 2003 to August 2007. Cryotherapy was performed with 2.4 mm diameter probes (Endocare, Irvine, CA) with ultrasound or computerized tomography (CT) guidance under conscious sedation and local anesthesia. Follow-up was conducted by imaging studies and clinical encounters, using Response Evaluation Criteria in Solid Tumors (RECIST criteria). Twenty-eight ablation sessions were performed for 41 metastatic foci in 15 patients with gynecologic malignancies. Twelve patients had prior chemotherapy and 5 patients had prior radiation. Median follow-up was 317.5 days (range 95-1189). Median post-procedure pain score: 3/10 (range 0-5). Mean initial tumor size was 2.6 cm in maximal diameter. Median reduction in tumor diameter at 1 month was 21.4% (range 2-67.4%), at 3 months was 43.6% (range 16-80.4%), at 6 months was 54.7% (range (16.6-88.9%) and at 9 months was 58.2% (range 32-88.9%). Ten patients received concurrent chemotherapy, 8 had progression of disease at other sites and 2 had stable disease, while the cryotherapy site improved. One of 5 patients who had cryotherapy in the previously irradiated zone had recurrence. A liver capsule hematoma developed as an immediate complication in one patient and an enterocutaneous fistula developed in another. IPC is a well-tolerated, effective tool for local control of isolated metastatic foci as a single-modality treatment and for local control of symptomatic metastases in select patients undergoing systemic therapy for the management of gynecologic malignancies.
Giannotti, Elisabetta; Vinnicombe, Sarah; Thomson, Kim; McLean, Dennis; Purdie, Colin; Jordan, Lee; Evans, Andy
2016-06-01
To establish if palpable breast masses with benign greyscale ultrasound features that are soft on shear-wave elastography (SWE) (mean stiffness <50 kPa) have a low enough likelihood of malignancy to negate the need for biopsy or follow-up. The study group comprised 694 lesions in 682 females (age range 17-95 years, mean age 56 years) presenting consecutively to our institution with palpable lesions corresponding to discrete masses at ultrasound. All underwent ultrasound, SWE and needle core biopsy. Static greyscale images were retrospectively assigned Breast Imaging Reporting and Data System (BI-RADS) scores by two readers blinded to the SWE and pathology findings, but aware of the patient's age. A mean stiffness of 50 kPa was used as the SWE cut-off for calling a lesion soft or stiff. Histological findings were used to establish ground truth. No cancer had benign characteristics on both modalities. 466 (99.8%) of the 467 cancers were classified BI-RADS 4a or above. The one malignant lesion classified as BI-RADS 3 was stiff on SWE. 446 (96%) of the 467 malignancies were stiff on SWE. No cancer in females under 40 years had benign SWE features. 74 (32.6%) of the 227 benign lesions were BI-RADS 3 and soft on SWE; so, biopsy could potentially have been avoided in this group. Lesions which appear benign on greyscale ultrasound and SWE do not require percutaneous biopsy or short-term follow-up, particularly in females under 40 years. None of the cancers had benign characteristics on both greyscale ultrasound and SWE, and 32% of benign lesions were BI-RADS 3 and soft on SWE; lesions that are benign on both ultrasound and SWE may not require percutaneous biopsy or short-term follow-up.
Kawakami, Hiroshi; Itoi, Takao; Sakamoto, Naoya
2014-07-01
Endoscopic drainage for pancreatic and peripancreatic fluid collections (PFCs) has been increasingly used as a minimally invasive alternative to surgical or percutaneous drainage. Recently, endoscopic ultrasound-guided transluminal drainage (EUS-TD) has become the standard of care and a safe procedure for nonsurgical PFC treatment. EUS-TD ensures a safe puncture, avoiding intervening blood vessels. Single or multiple plastic stents (combined with a nasocystic catheter) were used for the treatment of PFCs for EUS-TD. More recently, the use of covered self-expandable metallic stents (CSEMSs) has provided a safer and more efficient approach route for internal drainage. We focused our review on the best approach and stent to use in endoscopic drainage for PFCs. We reviewed studies of EUS-TD for PFCs based on the original Atlanta Classification, including case reports, case series, and previous review articles. Data on clinical outcomes and adverse events were collected retrospectively. A total of 93 patients underwent EUS-TD of pancreatic pseudocysts using CSEMSs. The treatment success and adverse event rates were 94.6% and 21.1%, respectively. The majority of complications were of mild severity and resolved with conservative therapy. A total of 56 patients underwent EUS-TD using CSEMSs for pancreatic abscesses or infected walled-off necroses. The treatment success and adverse event rates were 87.8% and 9.5%, respectively. EUS-TD can be performed safely and efficiently for PFC treatment. Larger diameter CSEMSs without additional fistula tract dilation for the passage of a standard scope are needed to access and drain for PFCs with solid debris.
Guided Interventions for Prostate Cancer Using 3D-Transurethral Ultrasound and MRI Fusion
2015-10-01
AWARD NUMBER: W81XWH-14-1-0461 TITLE: Guided Interventions for Prostate Cancer Using 3D-Transurethral Ultrasound and MRI Fusion PRINCIPAL...Sep 2014 - 28 Sep 2015 4. TITLE AND SUBTITLE 5a. CONTRACT NUMBER Guided Interventions for Prostate Cancer Using 3D- Transurethral Ultrasound and...Magnetic Resonance- Ultrasound (MR-US) fusion allows for specific targeting of the tumors in real-time during clinical interventions, outside of an MR
Yan, X; Zhao, C; Tian, C; Wen, S; He, X; Zhou, Y
2017-08-01
To explore HIFU treatment for uterine arteriovenous malformation. A case report. Gynaecological department in a university teaching hospital of China. A patient with uterine arteriovenous malformation. The diagnosis of uterine arteriovenous malformation was made through MRI. Ultrasound-guided high-intensity focused ultrasound (USgHIFU) ablation was performed. HIFU is effective in treating uterine arteriovenous malformation. The patient had reduction of the lesion volume and obvious symptom relief, without significant adverse effects. HIFU can be used as a new treatment option for uterine arteriovenous malformation. Ultrasound-guided high-intensity focused ultrasound ablation is effective in treating uterine arteriovenous malformation. © 2017 Royal College of Obstetricians and Gynaecologists.
Robert, B; Chivot, C; Rebibo, L; Sabbagh, C; Regimbeau, J-M; Yzet, T
2016-02-01
Interventional radiology plays an important role in the management of deep pelvic abscesses. Percutaneous drainage is currently considered as the first-line alternative to surgery. A transgluteal computed tomography (CT)-guided approach allows to access to deep infected collections avoiding many anatomical obstacles (vessels, nerves, bowel, bladder). The objective of this study was to assess the safety and efficacy of a transgluteal approach by reviewing our clinical experience. We reviewed medical records of patients having undergone percutaneous CT-guided transgluteal drainage for deep pelvic abscesses. We focused on the duration of catheter drainage, the complications related to the procedures and the rate of complete resolution. Between 2005 and 2013, 39patients (27women and 12men; mean age: 52.5) underwent transgluteal approach CT-guided percutaneous drainage of pelvis abscesses in our department. The origins of abscesses were postoperative complications in 34patients (87.2%) and infectious intra-abdominal disease in 5patients (12.8%). The mean duration of drainage was 8.3days (range: 3-33). Laboratory cultures were positive in 35patients (89.7%) and Escherichia coli was present in 71.4% of the positive samples. No major complication was observed. Drainage was successful in 38patients (97.4%). A transpiriformis approach was more significantly associated with intra-procedural pain (P=0.003). Percutaneous CT-guided drainage with a transgluteal approach is a safe, well-tolerated and effective alternative to surgery for deep pelvic abscesses. This approach should be considered as the first-line intention for the treatment of deep pelvic abscesses. Copyright © 2015 Elsevier Masson SAS. All rights reserved.
Yu, Aixi; Qi, Baiwen
2014-01-01
Background It is controversial whether ultrasound-guided injection of corticosteroid is superior to palpation-guided injection for plantar fasciitis. This meta-analysis was performed to compare the effectiveness of ultrasound-guided and palpation-guided injection of corticosteroid for the treatment of plantar fasciitis. Methods Databases (MEDLINE, Cochrane library and EMBASE) and reference lists were searched from their establishment to August 30, 2013 for randomized controlled trials (RCTs) comparing ultrasound-guided with palpation-guided injection for plantar fasciitis. The Cochrane risk of bias (ROB) tool was used to assess the methodological quality. Outcome measurements were visual analogue scale (VAS), tenderness threshold (TT), heel tenderness index (HTI), response rate, plantar fascia thickness (PFT), hypoechogenicity and heel pad thickness (HPT). The statistical analysis was performed with software RevMan 5.2 and Stata 12.0. When I2<50%, the fixed-effects model was adopted. Otherwise the randomized-effects model was adopted. The Grading of Recommendations Assessment, Development and Evaluation (GRADE) system was used to assess the quality of evidence. Results Five RCTs with 149 patients were identified and analyzed. Compared with palpation-guided injection, ultrasound-guided injection was superior with regard to VAS, TT, response rate, PFT and hypoechogenicity. However, there was no statistical significance between the two groups for HPT and HTI. Conclusion Ultrasound-guided injection of corticosteroid tends to be more effective than palpation-guided injection. However, it needs to be confirmed by further research. PMID:24658102
Allam, Abdallah El-Sayed; Khalil, Adham Aboul Fotouh; Eltawab, Basma Aly; Wu, Wei-Ting
2018-01-01
Orofacial myofascial pain is prevalent and most often results from entrapment of branches of the trigeminal nerves. It is challenging to inject branches of the trigeminal nerve, a large portion of which are shielded by the facial bones. Bony landmarks of the cranium serve as important guides for palpation-guided injections and can be delineated using ultrasound. Ultrasound also provides real-time images of the adjacent muscles and accompanying arteries and can be used to guide the needle to the target region. Most importantly, ultrasound guidance significantly reduces the risk of collateral injury to vital neurovascular structures. In this review, we aimed to summarize the regional anatomy and ultrasound-guided injection techniques for the trigeminal nerve and its branches, including the supraorbital, infraorbital, mental, auriculotemporal, maxillary, and mandibular nerves. PMID:29808105
Deora, Surender; Shah, Sanjay C; Patel, Tejas M
2015-01-01
Percutaneous coronary interventions (PCIs) of saphenous vein grafts (SVGs) is challenging and is associated with adverse short- and long-term clinical outcome as compared to native coronary arteries. SVG perforation is rare but catastrophic and needs immediate attention. Various factors predisposing for SVG perforation are old degenerated graft, ulcerated plaque, severe fibrotic, or calcified lesion necessitating high pressure balloon or stent inflation, use of intravascular ultrasound (IVUS) or other atheroablative devices. Management includes prolonged balloon occlusion, reversal of anticoagulation, use of covered stent, and emergency pericadiocentesis if required.
Kumar, Manoj; Goel, Prabudh; Rawat, J D; Kumari, Shweta; Shankhwar, S N; Kureel, S N
2013-05-01
We present our experience with an indigenously designed percutaneous trans-hepatic ultrasound-guided Gelfoam sponge cum cyanoacrylate glue-based embolization technique for the treatment of a ruptured post-traumatic aneurysm of a branch of the right hepatic artery (RHA) as a 'life-saving emergent' procedure in a patient unfit for surgery or endovascular intervention and in a 'limited-resource' scenario (non-availability of Digital Subtraction Angiography Suite). An 8-year-old boy sustained crush-injury to the right lobe of the liver in a road-traffic accident and presented in shock. After resuscitation, a laparotomy and repair of the right lobe of liver were undertaken. Bleeding restarted 1 week after the surgery; the patient bled from drain site and went into shock. Exploration was not advisable in view of poor general condition, and sepsis, deranged coagulation and parental reluctance in view of guarded prognosis. Multi-detector Computed Tomography Angiography was performed after resuscitation which revealed active bleed from a ruptured pseudo-aneurysm of a branch of RHA. The bleeding artery was identified with duplex sonography and was embolized by the percutaneous trans-hepatic route proximal to the site of pseudo-aneurysm and rupture by a two-step process. Initially, a thin paste/'slurry' made of powdered gelfoam dissolved in sterile saline was injected into the bleeding vessel. Subsequently, the area was sealed by injecting 1.0 ml of N-butyl-2-cyanoacrylate glue. Hemostasis was confirmed by Color and Power Doppler Ultrasonography both post-procedure and after 48 h. With supportive management, the patient showed a rapid recovery and was discharged after 2 weeks. He continues to be well at 3-month follow-up. The technique was effective in controlling hemostasis and life-saving in our set-up.
Gallego Herrero, C; Navarro Cutillas, V
Analyze statistically the success, number of sessions required and complete duration of treatment of agents used in pediatric percutaneous sclerotherapy of lymphatic malformations, to determine the most suitable. Retrospective study based on outcomes from percutaneous sclerotherapy performed on lymphatic malformations of 56 patients conducted by pediatric interventional radiologist for 14 years. As first approach, the procedure consists of ultrasound-guided introduction of sclerosing agent. Sessions were repeated until clinical resolution. Success, number of sessions and the duration of treatment were recorded and statistical treatment of the data was performed to obtain further conclusions. Lost patients in follow up and other minority agents used were excluded from the data. Eventually, 52 patients treated with OK432 (n=29), Ethibloc (n=5) and combination therapy (n=18) were included. The average number of sessions and duration in months of treatment was respectively 2.38 and 8.6 for OK432, 1.4 and 5.6 for Ethibloc, and 1.83 and 2.30 for dual therapy. The results were statistically significant for the difference in duration between OK432 and dual therapy. Also, 60-80% of patients reached proper results related to success, but the difference was no significant among the agents. Other demographic and anatomical variables were analyzed, not showing any difference, which supports the homogeneity of the sample. Despite of no significant difference in success and number of sessions among agents, longer duration of treatment with OK432 than dual therapy could mean greater health costs and probably greater disturb for patient and family. Copyright © 2017 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.
Hull, Jeffrey E; Elizondo-Riojas, Guillermo; Bishop, Wendy; Voneida-Reyna, Yesenia L
2017-03-01
To evaluate the safety and efficacy of arteriovenous fistula (AVF) creation with a thermal resistance anastomosis device (TRAD). From January 2014 to March 2015, 26 patients underwent ultrasound (US)-guided percutaneous creation of proximal radial artery-to-perforating vein AVFs with a TRAD that uses heat and pressure to create a fused anastomosis. Primary endpoints were fistula creation, patent fistula by Doppler US, two-needle dialysis at the prescribed rate, and device-related complications. Technical success rate of fistula creation was 88% (23 of 26). Procedure time averaged 18.4 minutes (range, 5-34 min), and 96% of anastomoses (22 of 23) were fused. At 6 weeks, 87% of AVFs (20 of 23) were patent, 61% (14 of 23) had 400-mL/min brachial artery flow, 1 patient was receiving dialysis, 2 fistulae had thrombosed, and 1 patient had died unrelated to the procedure. Eighty percent (16 of 20), 70% (14 of 20), and 60% (12 of 20) of patients were receiving dialysis at 3, 6, and 12 months; 4 patients died, 3 fistulae failed, and one patient was lost to follow-up. Overall, 87% of AVFs (20 of 23) had an additional procedure at a mean of 56 days (range, 0-239 d), including balloon dilation in 43% (n = 10), brachial vein embolization in 26% (n = 6), basilic vein ligation in 17% (n = 4), venous transposition in 30% (n = 7), and valvulotomy in 4% (n = 1). There were no major complications related to the device. Percutaneous AVFs created with a TRAD met the safety endpoints of this study. Midterm follow-up demonstrated intact anastomoses and fistulae suitable for dialysis. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.
Avritscher, Rony; Abdelsalam, Mohamed E; Javadi, Sanaz; Ensor, Joe; Wallace, Michael J; Alt, Eckhard; Madoff, David C; Vykoukal, Jody V
2013-12-01
To investigate the safety and effectiveness of a novel endovascular approach for therapeutic cell delivery using a balloon occlusion catheter in a large animal model of liver fibrosis. Transcatheter arterial embolization with ethiodized oil (Ethiodol) and ethanol was used to induce liver damage in 11 pigs. Mesenchymal stem cells (MSCs) were harvested from adipose tissue and engineered to express green fluorescent protein (GFP). A balloon occlusion catheter was positioned in the bilateral first-order portal vein branches 2 weeks after embolization to allow intraportal application of MSCs in six experimental animals. MSCs were allowed to dwell for 10 minutes using prolonged balloon inflation. Five control animals received a sham injection of normal saline in a similar fashion. Hepatic venous pressure gradient (HVPG) was measured immediately before necropsy. Specimens from all accessible lobes were obtained with ultrasound-guided percutaneous 18-gauge biopsy 2 hours after cell application. All animals were euthanized within 4 weeks. Fluorescent microscopy was used to assess the presence and distribution of cells. Liver injury and fibrosis were successfully induced in all animals. MSCs (6-10 × 10(7)) were successfully delivered into the portal vein in the six experimental animals. Cell application was not associated with vascular complications. HVPG showed no instances of portal hypertension. GFP-expressing MSCs were visualized in biopsy specimens and were distributed primarily within the sinusoidal spaces; however, 4 weeks after implantation, MSCs could not be identified in histologic specimens. A percutaneous endovascular approach for cell delivery using a balloon occlusion catheter proved safe for intraportal MSC application in a large animal model of liver fibrosis. © 2013 SIR Published by SIR All rights reserved.
Zhang, Lu; Zhou, Wei; Zhan, WeiWei
2018-04-01
Background Few studies have examined the feasibility and efficiency of performing ultrasound and contrast-enhanced ultrasound (CEUS) after percutaneous laser ablation (PLA) of cervical metastatic lymph nodes from thyroid cancer. Purpose To investigate and describe the use of conventional ultrasound and CEUS in evaluating PLA of metastatic lymph nodes. Material and Methods PLA was performed in a small, prospective, observational study of 21 metastatic lymph nodes in 17 thyroid cancer patients who underwent radical thyroid resection. CEUS was conducted prior to PLA and 1 h and seven days after ablation. Conventional ultrasound examination of all nodes was performed during follow-up after ablation. We observed contrast agent perfusion in the lymph nodes, calculated perfusion defect volumes using CEUS and determined the rates of reduction for metastatic lymph nodes for a mean duration of 17.86 ± 4.704 months (range = 12-27 months). Results CEUS demonstrated that the perfusion defect volume was larger on day 7 than on day 1 post-ablation in 47% of the ablated nodes. Compared to the largest diameters and volumes pre-PLA, the corresponding post-PLA values significantly decreased ( P < 0.05 versus baseline). No statistically significant change in thyroglobulin (Tg) levels before and after PLA was observed in this study ( P > 0.05 versus baseline). Conclusion CEUS can be effectively used to distinguish the margins of ablated regions, assess the accuracy of PLA, and monitor short-term changes in necrotic areas. However, long-term follow-up assessments of the curative effect of PLA will predominantly rely on conventional ultrasonography.
Cost-effectiveness of focused ultrasound, radiosurgery, and DBS for essential tremor.
Ravikumar, Vinod K; Parker, Jonathon J; Hornbeck, Traci S; Santini, Veronica E; Pauly, Kim Butts; Wintermark, Max; Ghanouni, Pejman; Stein, Sherman C; Halpern, Casey H
2017-08-01
Essential tremor remains a very common yet medically refractory condition. A recent phase 3 study demonstrated that magnetic resonance-guided focused ultrasound thalamotomy significantly improved upper limb tremor. The objectives of this study were to assess this novel therapy's cost-effectiveness compared with existing procedural options. Literature searches of magnetic resonance-guided focused ultrasound thalamotomy, DBS, and stereotactic radiosurgery for essential tremor were performed. Pre- and postoperative tremor-related disability scores were collected from 32 studies involving 83 magnetic resonance-guided focused ultrasound thalamotomies, 615 DBSs, and 260 stereotactic radiosurgery cases. Utility, defined as quality of life and derived from percent change in functional disability, was calculated; Medicare reimbursement was employed as a proxy for societal cost. Medicare reimbursement rates are not established for magnetic resonance-guided focused ultrasound thalamotomy for essential tremor; therefore, reimbursements were estimated to be approximately equivalent to stereotactic radiosurgery to assess a cost threshold. A decision analysis model was constructed to examine the most cost-effective option for essential tremor, implementing meta-analytic techniques. Magnetic resonance-guided focused ultrasound thalamotomy resulted in significantly higher utility scores compared with DBS (P < 0.001) or stereotactic radiosurgery (P < 0.001). Projected costs of magnetic resonance-guided focused ultrasound thalamotomy were significantly less than DBS (P < 0.001), but not significantly different from radiosurgery. Magnetic resonance-guided focused ultrasound thalamotomy is cost-effective for tremor compared with DBS and stereotactic radiosurgery and more effective than both. Even if longer follow-up finds changes in effectiveness or costs, focused ultrasound thalamotomy will likely remain competitive with both alternatives. © 2017 International Parkinson and Movement Disorder Society. © 2017 International Parkinson and Movement Disorder Society.
Hishikawa, Shuji; Kobayashi, Eiji; Sugimoto, Koh-ichi; Miyata, Michio; Fujimura, Akio
2001-01-01
Aims To examine diurnal variation in biliary excretion of flomoxef. Methods Flomoxef (1 g) was injected intravenously in eight patients with percutaneous transhepatic cholangiography with drainage at 09.00 h and 21.00 h by a cross-over design with a 36 h washout period. Drained biliary fluid was collected for 6 h after each dosing. These patients still had mild to moderate hepatic dysfunction. Results Bile flow and bile acid excretion for 6 h after dosing did not differ significantly between the 09.00 h and 21.00 h treatments. The maximum concentration of biliary flomoxef was significantly greater and its total excretion for 6 h tended to be greater after the 21.00 h dose [maximum concentration (µg ml−1): 34.2 ± 29.9 (09.00 h dose) vs 43.5 ± 28.3 (21.00 h dose) (95% confidence interval for difference: 2.6∼15.9, P = 0.013); total excretion (mg 6 h−1): 1.4 ± 1.3 (09.00 h dose) vs 1.6 ± 1.2 (21.00 h dose) (95% confidence interval for difference: −26.8, 313.7, P = 0.087)]. The period that biliary flomoxef remained above the minimal inhibitory concentration did not differ significantly between the two treatment times. Conclusions These results suggest that biliary excretion of flomoxef shows diurnal variation. However, as the difference was relatively small, flomoxef could be given at any time of day without any dosage adjustments. PMID:11453891
Hishikawa, S; Kobayashi, E; Sugimoto , K; Miyata, M; Fujimura, A
2001-07-01
To examine diurnal variation in biliary excretion of flomoxef. Flomoxef (1 g) was injected intravenously in eight patients with percutaneous transhepatic cholangiography with drainage at 09.00 h and 21.00 h by a cross-over design with a 36 h washout period. Drained biliary fluid was collected for 6 h after each dosing. These patients still had mild to moderate hepatic dysfunction. Bile flow and bile acid excretion for 6 h after dosing did not differ significantly between the 09.00 h and 21.00 h treatments. The maximum concentration of biliary flomoxef was significantly greater and its total excretion for 6 h tended to be greater after the 21.00 h dose [maximum concentration (microg ml(-1)): 34.2 +/- 29.9 (09.00 h dose) vs 43.5 +/- 28.3 (21.00 h dose) (95% confidence interval for difference: 2.6 approximately 15.9, P = 0.013); total excretion (mg 6 h(-1)): 1.4 +/- 1.3 (09.00 h dose) vs 1.6 +/- 1.2 (21.00 h dose) (95% confidence interval for difference: -26.8, 313.7, P = 0.087)]. The period that biliary flomoxef remained above the minimal inhibitory concentration did not differ significantly between the two treatment times. These results suggest that biliary excretion of flomoxef shows diurnal variation. However, as the difference was relatively small, flomoxef could be given at any time of day without any dosage adjustments.
Percutaneous CT-Guided Biopsy of C3 Vertebral Body: Modified Approach for an Old Procedure
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pua, Uei, E-mail: druei@yahoo.com; Chan, Stephen Yung-Wei
2013-06-15
Percutaneous biopsy of upper cervical vertebrae is challenging due to the various critical structures in the location and often requires difficult trajectory such as transoral or paramaxillary approaches. The purpose of this manuscript is to illustrate the utility of head rotation in creating a potential space for direct percutaneous access to C3 vertebral body for safe biopsy.
Fortmeier, Dirk; Mastmeyer, Andre; Schröder, Julian; Handels, Heinz
2016-01-01
This study presents a new visuo-haptic virtual reality (VR) training and planning system for percutaneous transhepatic cholangio-drainage (PTCD) based on partially segmented virtual patient models. We only use partially segmented image data instead of a full segmentation and circumvent the necessity of surface or volume mesh models. Haptic interaction with the virtual patient during virtual palpation, ultrasound probing and needle insertion is provided. Furthermore, the VR simulator includes X-ray and ultrasound simulation for image-guided training. The visualization techniques are GPU-accelerated by implementation in Cuda and include real-time volume deformations computed on the grid of the image data. Computation on the image grid enables straightforward integration of the deformed image data into the visualization components. To provide shorter rendering times, the performance of the volume deformation algorithm is improved by a multigrid approach. To evaluate the VR training system, a user evaluation has been performed and deformation algorithms are analyzed in terms of convergence speed with respect to a fully converged solution. The user evaluation shows positive results with increased user confidence after a training session. It is shown that using partially segmented patient data and direct volume rendering is suitable for the simulation of needle insertion procedures such as PTCD.
Lemoy, Marie-Josee MF; Westworth, Diccon R; Ardeshir, Amir; Tarara, Ross P
2013-01-01
The purpose of this study was to determine the 12-h fasting preprandial and 2-h postprandial serum bile acid concentration (SBAC) reference intervals for healthy, adult rhesus macaques (Macaca mulatta). We hypothesized that the mean 2-h postprandial SBAC would be significantly higher than the mean preprandial SBAC. We included 40 (24 male, 16 female) macaques after confirming that their health records, physical examinations, CBC, serum chemistry panels, and urinalyses were all within normal limits. In addition, hepatitis A titers were determined, an ultrasound examination of the liver was performed, and two 16-gauge ultrasound guided percutaneous liver biopsies were collected and submitted for histopathology. Macaques were confirmed healthy according to hepatitis A screens and sonographic and histologic evaluation of hepatic tissue. Within 2 wk of the screening procedures, preprandial and postprandial SBACs were measured. Preprandial SBAC (mean ± 1 SD) was 11.1 ± 1.9 µmol/L and postprandial SBAC was 19.7 ± 8.0 µmol/L, which was significantly higher than the preprandial value. Sex and hepatitis titers did not significantly influence preprandial and postprandial SBAC. The current study indicates that the SBAC reference values for rhesus macaques are higher than those reported for humans and companion animals. PMID:23849441
Laser, radiofrequency, and ethanol ablation for the management of thyroid nodules.
Papini, Enrico; Gugliemi, Rinaldo; Pacella, Claudio Maurizio
2016-10-01
The majority of benign thyroid nodules are nearly asymptomatic, remain stable in size, and do not require treatment. However, a minority of patients with growing nodules may complain of local symptoms or have cosmetic concerns, and thus seek surgical consultation. The timely use of ultrasound-guided minimally invasive procedures can change the natural history of benign enlarging thyroid nodules. The procedures produce persistent shrinkage of thyroid nodules and are associated with improvement of local symptoms. Among the various procedures, percutaneous ethanol injection represents the first-line treatment for relapsing thyroid cysts. In solid nonfunctioning nodules, laser and radiofrequency ablation produces a more than 50% reduction in nodular volume that remains persistent over several years. For hyperfunctioning nodules, thermal ablation techniques are not appropriate unless radioactive iodine is contraindicated or not accessible. MITs are best suited for the management of medium or large-sized nodules that are sonographically well visualized. Conversely, large nodules or nodular goiters that extend into the chest are difficult to treat. MITs are performed in outpatient clinics, are less expensive, and have a lower risk of complications, compared to surgery, and usually do not induce thyroid dysfunction. However, malignancy should be ruled out with a dedicated ultrasound neck assessment and repeat fine needle aspiration of the lesion before treatment.
Lemoy, Marie-Josee M F; Westworth, Diccon R; Ardeshir, Amir; Tarara, Ross P
2013-07-01
The purpose of this study was to determine the 12-h fasting preprandial and 2-h postprandial serum bile acid concentration (SBAC) reference intervals for healthy, adult rhesus macaques (Macaca mulatta). We hypothesized that the mean 2-h postprandial SBAC would be significantly higher than the mean preprandial SBAC. We included 40 (24 male, 16 female) macaques after confirming that their health records, physical examinations, CBC, serum chemistry panels, and urinalyses were all within normal limits. In addition, hepatitis A titers were determined, an ultrasound examination of the liver was performed, and two 16-gauge ultrasound guided percutaneous liver biopsies were collected and submitted for histopathology. Macaques were confirmed healthy according to hepatitis A screens and sonographic and histologic evaluation of hepatic tissue. Within 2 wk of the screening procedures, preprandial and postprandial SBACs were measured. Preprandial SBAC (mean ± 1 SD) was 11.1 ± 1.9 μmol/L and postprandial SBAC was 19.7 ± 8.0 μmol/L, which was significantly higher than the preprandial value. Sex and hepatitis titers did not significantly influence preprandial and postprandial SBAC. The current study indicates that the SBAC reference values for rhesus macaques are higher than those reported for humans and companion animals.
Elagili, Faisal; Abdullah, Norlia; Fong, Liew; Pei, Tan
2007-01-01
To assess ultrasonographically (US) guided needle aspiration of breast abscesses as an alternative to surgical incision and drainage. In our prospective study, 30 patients with 31 breast abscesses (one patient had bilateral breast abscess) underwent percutaneous breast abscess drainage under US guidance with local anaesthesia and oral antibiotics between 1 January 2004 and 31 March 2005. These patients consisted of 16 (53.3%) non-lactating and 14 (46.7%) lactating women, with ages ranging from 18 to 68 years (median, 28 years). The racial distribution comprised 26 (86.7%) Malays, three (10%) Chinese and one (3.3%) Indian. All patients had the chief complaint of breast swelling and 25 (83.3%) had breast pain. Clinically, 28 (93.3%) were found to have a palpable mass. Nine (30%) lesions were in the upper outer quadrant of the left breast. US diameters ranged from 1 to 15 cm (median, 4 cm). The pus volumes varied from 1 to 200 mL (median, 14 mL). Fifteen (50%) patients required only a single aspiration, 10 required multiple aspirations and five required incision and drainage. Those patients in whom needle aspiration failed had multiloculated lesions irrespective of abscess volume and size. Needle aspiration with ultrasound guidance is an effective treatment for breast abscess irrespective of abscess volume and size.
Efficacy of ultrasound-guided thoracentesis catheter drainage for pleural effusion
Cao, Weitian; Wang, Yi; Zhou, Ningming; Xu, Bing
2016-01-01
The factors influencing the efficacy of ultrasound-guided thoracentesis catheter drainage were investigated in the present study. A retrospective analysis of clinical data from 435 patients who presented with a pleural effusion was performed. Patients were divided into a control group and an intervention group. Thirty-seven patients in the control group were given standard care using pleural puncture to draw the excess fluid. The 398 patients in the intervention group were treated using ultrasound-guided thoracentesis catheter drainage. The rate of successful drainage of a pleural effusion was significantly higher (P<0.05), while the rate of complication was lower, in the ultrasound-guided thoracentesis cases compared to standard care treatment. In conclusion, ultrasound-guided thoracentesis catheter drainage is an efficient, safe and minimally invasive procedure to alleviate pleural effusion. The efficacy of the procedure is related to the separation of pleural effusion, drainage tube type and tube diameter. PMID:28105155
Technical tips to perform safe and effective ultrasound guided steroid joint injections in children.
Parra, Dimitri A
2015-01-01
The aim of this article is to describe the technique used to perform ultrasound guided steroid joint injections in children in a group of joints that can be injected using ultrasound as the only image guidance modality. The technique is described and didactic figures are provided to illustrate key technical concepts. It is very important to be familiar with the sonographic appearance of the pediatric joints and the developing bone when performing ultrasound-guided joint injections in children.
Garnon, Julien; Koch, Guillaume; Ramamurthy, Nitin; Caudrelier, Jean; Rao, Pramod; Tsoumakidou, Georgia; Cazzato, Roberto Luigi; Gangi, Afshin
2016-09-01
To review our initial experience with percutaneous CT and fluoroscopy-guided screw fixation of pathological shoulder-girdle fractures. Between May 2014 and June 2015, three consecutive oncologic patients (mean age 65 years; range 57-75 years) with symptomatic pathological shoulder-girdle fractures unsuitable for surgery and radiotherapy underwent percutaneous image-guided screw fixation. Fractures occurred through metastases (n = 2) or a post-ablation cavity (n = 1). Mechanical properties of osteosynthesis were adjudged superior to stand-alone cementoplasty in each case. Cannulated screws were placed under combined CT and fluoroscopic guidance with complementary radiofrequency ablation or cementoplasty to optimise local palliation and secure screw fixation, respectively, in two cases. Follow-up was undertaken every few weeks until mortality or most recent appointment. Four pathological fractures were treated in three patients (2 acromion, 1 clavicular, 1 coracoid). Mean size of associated lesion was 2.6 cm (range 1-4.5 cm). Technical success was achieved in all cases (100 %), without complications. Good palliation and restoration of mobility were observed in two cases at 2-3 months; one case could not be followed due to early post-procedural oncologic mortality. Percutaneous image-guided shoulder-girdle osteosynthesis appears technically feasible with good short-term efficacy in this complex patient subset. Further studies are warranted to confirm these promising initial results.
Outcome of percutaneous continuous drainage of psoas abscess: A clinically guided technique.
Dave, Bharat R; Kurupati, Ranganatha Babu; Shah, Dipak; Degulamadi, Devanand; Borgohain, Nitu; Krishnan, Ajay
2014-01-01
Percutaneous aspiration of abscesses under ultrasonography (USG) and computer tomography (CT) scan has been well described. With recurrence rate reported as high as 66%. The open drainage and percutaneous continuous drainage (PCD) has reduced the recurrence rate. The disadvantage of PCD under CT is radiation hazard and problems of asepsis. Hence a technique of clinically guided percutaneous continuous drainage of the psoas abscess without real-time imaging overcomes these problems. We describe clinically guided PCD of psoas abscess and its outcome. Twenty-nine patients with dorsolumbar spondylodiscitis without gross neural deficit with psoas abscess of size >5 cm were selected for PCD. It was done as a day care procedure under local anesthesia. Sequentially, aspiration followed by guide pin-guided trocar and catheter insertion was done without image guidance. Culture sensitivity was done and chemotherapy initiated and catheter kept till the drainage was <10 ml for 48 hours. Outcome assessment was done with relief of pain, successful abscess drainage and ODI (Oswestry Disability Index) score at 2 years. PCD was successful in all cases. Back and radicular pain improved in all cases. Average procedure time was 24.30 minutes, drain output was 234.40 ml, and the drainage duration was 7.90 days. One patient required surgical stabilisation due to progression of the spondylodiscitis resulting in instability inspite of successful drainage of abscess. Problems with the procedure were noticed in six patients. Multiple attempts (n = 2), persistent discharge (n = 1) for 2 weeks, blocked catheter (n = 2) and catheter pull out (n = 1) occurred with no effect on the outcome. The average ODI score improved from 62.47 to 5.51 at 2 years. Clinically guided PCD is an efficient, safe and easy procedure in drainage of psoas abscess.
Zhou, Fubo; Yu, Xiaoling; Liang, Ping; Cheng, Zhigang; Han, Zhiyu; Yu, Jie; Liu, Fangyi; Tan, Shuilian; Dai, Guanghai; Bai, Li
2016-08-01
Oesophageal cancer is a highly aggressive disease with about 50% of patients presenting with advanced or metastatic disease at initial diagnosis. In this study we assessed combined microwave ablation (MWA) and systemic chemotherapy in the treatment of liver metastases arising from oesophageal squamous cell carcinoma (OSCC). Between February 2009 and June 2014, OSCC patients who underwent percutaneous MWA + concurrent systemic chemotherapy and systemic chemotherapy alone for liver metastases were enrolled in this study. Overall survival (OS) and progression-free survival (PFS) were recorded and compared between groups. In total 15 patients with 25 liver metastases who underwent ultrasound-guided percutaneous MWA and chemotherapy were enrolled in this study. Technical success was achieved in 96% (24/25) of metastatic liver tumours. No major or minor complications associated with MWA procedures were observed. The median OS and PFS from initial MWA were 13 months and 4 months. The 1-, 2-, 3-, 4-year OS rates after MWA were 53.3%, 26.7%, 13.3%, and 13.3%, respectively. The 1- and 2-year PFS rates after MWA were 26.7% and 13.3%. The OS and PFS of the MWA + systemic chemotherapy group were superior than those of patients who received systemic chemotherapy alone (P = 0.011 and 0.030, respectively). Combined MWA with systemic chemotherapy is a feasible, safe and effective treatment for liver metastases from OSCC.
Tay, Jun H; Wallbridge, Peter D; Larobina, Marco; Russell, Prudence A; Irving, Louis B; Steinfort, Daniel P
2016-07-01
Limited (wedge) resection of pulmonary lesions is frequently performed as a diagnostic/therapeutic procedure. Some lesions may be difficult to locate thoracoscopically with conversion to open thoracotomy or incomplete resection being potential limitations to this approach. Multiple methods have been described to aid video-assisted thoracoscopic surgical (VATS) wedge resection of pulmonary nodules, including hookwire localization, percutaneous tattoo, or intraoperative ultrasound. We report on our experience using electromagnetic navigation bronchoscopic dye marking of small subpleural lesions to aid VATS wedge resection. A retrospective cohort study of consecutive patients undergoing VATS wedge resection of peripheral lesions. Preoperative bronchoscopy with electromagnetic navigation was utilized to guide a 25 G needle to within/adjacent to the target lesion with injection of 1 mL of methylene blue or indigo carmine under fluoroscopic vision. Six patients underwent bronchoscopic marking of peripheral pulmonary lesions, navigation deemed successful in all patients, with no procedural complications. Surgery was performed within 24 hours of bronchoscopic marking. Pleural staining by dye was visible thoracoscopically in all 6 lesions either adjacent to or overlying the lesion. All lesions were fully excised with wedge resection. Pathologic examination confirmed accuracy of dye staining. Electromagnetic navigation bronchoscopic dye marking of peripheral lesions is feasible, without complications commonly associated with percutaneous marking procedures. Further experience is required but early findings suggest that this method may have utility in aiding minimally invasive resection of small subpleural lesions.
Splenic abscess: report of six cases and review of the literature.
Green, B T
2001-01-01
Splenic abscesses are rare but appear to be increasing in frequency. Recent advances in radiologic techniques have affected the diagnosis and management. The purpose of this study was to evaluate these effects. The medical records of one institution were retrospectively reviewed and six cases of splenic abscesses seen between 1989 and 1999 were identified. All patients had predisposing conditions with metastatic hematogenous infection in three and one each with trauma, immunodeficiency, and a contiguous site of infection. Fever was present in all patients with chills and vomiting in five and three patients, respectively. Left upper quadrant tenderness appeared in four patients and leukocytosis was found in every patient except one with the acquired immunodeficiency syndrome. Chest roentgenograms were abnormal in five patients with a left pleural effusion most common. Ultrasound revealed the defect in both patients it was utilized in and computed tomography was diagnostic in all cases. The causative organisms were anaerobes in two cases and Candida albicans, Streptococcus viridans, Escherichia coli, and Citrobacter freundii each present in one case. Radiology guided percutaneous drainage was attempted in four patients but was only successful in one. Splenectomy with antibiotics was curative in the remainder with a 100 per cent survival. These data suggest that percutaneous drainage may be appropriate for certain patients initially, but the high failure rate demonstrates that splenectomy remains the standard treatment.
Gong, Xiaohua; Zhou, Qi; Wang, Fang; Wu, Wenjun; Chen, Xiaojun
2017-01-01
To evaluate the efficacy and safety of percutaneous polidocanol injection (PPI) in treating cystic thyroid nodules. A total of 158 cystic or predominantly cystic thyroid nodules (>80% cystic component) in 143 patients were evaluated. 114 patients with compressive symptoms or aesthetic complaints were offered PPI. 44 individuals without compressive symptoms and aesthetic complaints who were only followed up clinically were used as the control group. The efficacy and safety of PPI were evaluated for 1 month, 3 months, 6 months, 9 months, and 12 months of follow-up. In the PPI group, the mean baseline volume of 15.6 ± 18.9 cm 3 reduced at the 1-month follow-up to 5.1 ± 5.6 cm 3 ( p < 0.001) and 0.6 ± 0.9 ( p < 0.001), and nodules shrunk according to the time after PPI ( p < 0.001). A complete response (if ≥70% decrease) to PPI at the 12-month follow-up occurred in 100% of the cystic or predominant cystic nodules. None of the nodules recurred at the 12-month follow-up after PPI. The side effects were mild. Twenty patients (17.5%) developed mild localized pain, and fourteen cases (12.3%) experienced mild or moderate fever after PPI. PPI is a safe and effective alternative to treat benign cystic or predominant cystic thyroid nodules.
Tarantino, Luciano; Busto, Giuseppina; Nasto, Aurelio; Fristachi, Raffaele; Cacace, Luigi; Talamo, Maria; Accardo, Catello; Bortone, Sara; Gallo, Paolo; Tarantino, Paolo; Nasto, Riccardo Aurelio; Di Minno, Matteo Nicola Dario; Ambrosino, Pasquale
2017-01-01
AIM To treated with electrochemotherapy (ECT) a prospective case series of patients with liver cirrhosis and Vp3-Vp4- portal vein tumor thrombus (PVTT) from hepatocellular carcinoma (HCC), in order to evaluate the feasibility, safety and efficacy of this new non thermal ablative technique in those patients. METHODS Six patients (5 males and 1 female), aged 61-85 years (mean age, 70 years), four in Child-Pugh A and two in Child-Pugh B class, entered our study series. All patients were studied with three-phase computed tomography (CT), contrast enhanced ultrasound (CEUS) and ultrasound-guided percutaneous biopsy of the thrombus before ECT. All patients underwent ECT treatment (Cliniporator Vitae®, IGEA SpA, Carpi, Modena, Italy) of Vp3-Vp4 PVTT in a single session. At the end of the procedure a post-treatment biopsy of the thrombus was performed. Scheduled follow-up in all patients entailed: CEUS within 24 h after treatment; triphasic contrast-enhanced CT and CEUS at 3 mo after treatment and every six months thereafter. RESULTS Post-treatment CEUS showed complete absence of enhancement of the treated thrombus in all cases. Post-treatment biopsy showed apoptosis and necrosis of tumor cells in all cases. The follow-up ranged from 9 to 20 mo (median, 14 mo). In 2 patients, the follow-up CT and CEUS demonstrated complete patency of the treated portal vein. Other 3 patients showed a persistent avascular non-tumoral shrinked thrombus at CEUS and CT during follow-up. No local recurrence was observed at follow-up CT and CEUS in 5/6 patients. One patient was lost to follow-up because of death from gastrointestinal hemorrage 5 wk after ECT. CONCLUSION In patients with cirrhosis, ECT seems effective and safe for curative treatment of Vp3-Vp4 PVTT from HCC. PMID:28223736
Tarantino, Luciano; Busto, Giuseppina; Nasto, Aurelio; Fristachi, Raffaele; Cacace, Luigi; Talamo, Maria; Accardo, Catello; Bortone, Sara; Gallo, Paolo; Tarantino, Paolo; Nasto, Riccardo Aurelio; Di Minno, Matteo Nicola Dario; Ambrosino, Pasquale
2017-02-07
To treated with electrochemotherapy (ECT) a prospective case series of patients with liver cirrhosis and Vp3-Vp4- portal vein tumor thrombus (PVTT) from hepatocellular carcinoma (HCC), in order to evaluate the feasibility, safety and efficacy of this new non thermal ablative technique in those patients. Six patients (5 males and 1 female), aged 61-85 years (mean age, 70 years), four in Child-Pugh A and two in Child-Pugh B class, entered our study series. All patients were studied with three-phase computed tomography (CT), contrast enhanced ultrasound (CEUS) and ultrasound-guided percutaneous biopsy of the thrombus before ECT. All patients underwent ECT treatment (Cliniporator Vitae ® , IGEA SpA, Carpi, Modena, Italy) of Vp3-Vp4 PVTT in a single session. At the end of the procedure a post-treatment biopsy of the thrombus was performed. Scheduled follow-up in all patients entailed: CEUS within 24 h after treatment; triphasic contrast-enhanced CT and CEUS at 3 mo after treatment and every six months thereafter. Post-treatment CEUS showed complete absence of enhancement of the treated thrombus in all cases. Post-treatment biopsy showed apoptosis and necrosis of tumor cells in all cases. The follow-up ranged from 9 to 20 mo (median, 14 mo). In 2 patients, the follow-up CT and CEUS demonstrated complete patency of the treated portal vein. Other 3 patients showed a persistent avascular non-tumoral shrinked thrombus at CEUS and CT during follow-up. No local recurrence was observed at follow-up CT and CEUS in 5/6 patients. One patient was lost to follow-up because of death from gastrointestinal hemorrage 5 wk after ECT. In patients with cirrhosis, ECT seems effective and safe for curative treatment of Vp3-Vp4 PVTT from HCC.
Lee, Se Won; Tiu, Timothy; Roberts, Jeremy; Lee, Brian; Bartels, Matthew N; Oh-Park, Mooyeon
2018-01-01
The aims of the study were to assess the overall reduction of pain in patients undergoing ultrasound-guided shoulder injections and to characterize the preinjection point-of-care ultrasound findings and use of clinical services postinjection including the use of magnetic resonance imaging and surgeries. Data of 172 patients who underwent ultrasound-guided subacromial subdeltoid injection or glenohumeral joint injection were reviewed for preinjection point-of-care ultrasound findings, change in pain intensity at 2 mos from baseline, and use of care at 6 mos' postinjection. Pain intensity was measured by the numeric rating scale and a dichotomous report of global impression of significant improvement in pain. Responders were defined as those with 50% or more reduction in numeric rating scale or those with global impression of 50% or more improvement. There were 141 responders among the 172 patients analyzed. Full-thickness rotator cuff tears were higher in the ultrasound-guided subacromial subdeltoid injection group when compared with the glenohumeral joint injection group (P = 0.038) and abnormal bicipital tendon findings higher in the glenohumeral joint injection group (P = 0.016). There were no significant differences in specific abnormal U findings between responders versus nonresponders. Twelve patients had a shoulder magnetic resonance imaging and four patients underwent operative interventions after the injection. Overall pain reduction after ultrasound-guided shoulder injections was favorable in the short term. There was no specific preinjection point-of-care ultrasound findings associated with clinical pain reduction after injection. Additional imaging and operative intervention after ultrasound-guided shoulder injections seemed to be relatively low.
García-Blas, Sergio; Núñez, Julio; Mainar, Luis; Miñana, Gema; Bonanad, Clara; Racugno, Paolo; Rodríguez, Juan Carlos; Moyano, Patricia; Sanchis, Juan
2015-01-01
Objective The aim of this study was to describe our initial experience with the GuideLiner® catheter (Vascular Solutions Inc.) in the transradial treatment of complex lesions. Materials and Methods The clinical, angiographic and procedural data of percutaneous coronary interventions where GuideLiner was used during 2013 were collected. The transradial approach was used in all cases. The indication for its use, efficacy and periprocedural complications were determined. Sixteen consecutive procedures (in 15 patients; 12 males and 3 females) were evaluated. The indication for the use of GuideLiner was a difficulty to advance and properly position a stent through a tortuous and/or calcified artery despite using high-support guide catheters or other useful techniques. Results Of the 16 angiographic procedures, 14 (87.5s%) were successful (stent deployment in 13 cases and a drug-eluting balloon in 1 case). Unsuccessful cases were a chronic total occlusion and a diffusely diseased left anterior descendant artery. A type B dissection of a proximal left circumflex artery was the only periprocedural complication. Conclusion Use of the GuideLiner was an effective and safe technique for the percutaneous treatment of complex coronary lesions in which the adequate progress of angioplasty devices had failed. GuideLiner was particularly helpful when using the transradial approach. Only one minor complication was recorded. PMID:25531292
García-Blas, Sergio; Núñez, Julio; Mainar, Luis; Miñana, Gema; Bonanad, Clara; Racugno, Paolo; Rodríguez, Juan Carlos; Moyano, Patricia; Sanchis, Juan
2015-01-01
The aim of this study was to describe our initial experience with the GuideLiner® catheter (Vascular Solutions Inc.) in the transradial treatment of complex lesions. The clinical, angiographic and procedural data of percutaneous coronary interventions where GuideLiner was used during 2013 were collected. The transradial approach was used in all cases. The indication for its use, efficacy and periprocedural complications were determined. Sixteen consecutive procedures (in 15 patients; 12 males and 3 females) were evaluated. The indication for the use of GuideLiner was a difficulty to advance and properly position a stent through a tortuous and/or calcified artery despite using high-support guide catheters or other useful techniques. Of the 16 angiographic procedures, 14 (87.5%) were successful (stent deployment in 13 cases and a drug-eluting balloon in 1 case). Unsuccessful cases were a chronic total occlusion and a diffusely diseased left anterior descendant artery. A type B dissection of a proximal left circumflex artery was the only periprocedural complication. Use of the GuideLiner was an effective and safe technique for the percutaneous treatment of complex coronary lesions in which the adequate progress of angioplasty devices had failed. GuideLiner was particularly helpful when using the transradial approach. Only one minor complication was recorded. © 2014 S. Karger AG, Basel.
PLUS: open-source toolkit for ultrasound-guided intervention systems.
Lasso, Andras; Heffter, Tamas; Rankin, Adam; Pinter, Csaba; Ungi, Tamas; Fichtinger, Gabor
2014-10-01
A variety of advanced image analysis methods have been under the development for ultrasound-guided interventions. Unfortunately, the transition from an image analysis algorithm to clinical feasibility trials as part of an intervention system requires integration of many components, such as imaging and tracking devices, data processing algorithms, and visualization software. The objective of our paper is to provide a freely available open-source software platform-PLUS: Public software Library for Ultrasound-to facilitate rapid prototyping of ultrasound-guided intervention systems for translational clinical research. PLUS provides a variety of methods for interventional tool pose and ultrasound image acquisition from a wide range of tracking and imaging devices, spatial and temporal calibration, volume reconstruction, simulated image generation, and recording and live streaming of the acquired data. This paper introduces PLUS, explains its functionality and architecture, and presents typical uses and performance in ultrasound-guided intervention systems. PLUS fulfills the essential requirements for the development of ultrasound-guided intervention systems and it aspires to become a widely used translational research prototyping platform. PLUS is freely available as open source software under BSD license and can be downloaded from http://www.plustoolkit.org.
Hong, Ji Seong; Lee, Jin Hyung
2016-01-01
Objective To evaluate the feasibility and effect of ultrasound-guided ethyl alcohol injection on malleolar and olecranon synovial proliferative bursitis. Methods Twenty-four patients received ultrasound-guided 50% diluted ethyl alcohol injection at the site of synovial proliferative bursitis after aspiration of the free fluid. Results Swelling and symptoms significantly decreased in 13 of the 24 patients without any complications. Eleven patients had partial improvement in swelling and symptoms. Conclusion Ultrasound-guided alcohol injection could be an alternative therapeutic option before surgery in patients with chronic intractable malleolar and olecranon synovial proliferative bursitis. PMID:27152282
Fürst, Rafael Vilhena de Carvalho; Polimanti, Afonso César; Galego, Sidnei José; Bicudo, Maria Claudia; Montagna, Erik; Corrêa, João Antônio
2017-03-01
To present a simple and affordable model able to properly simulate an ultrasound-guided venous access. The simulation was made using a latex balloon tube filled with water and dye solution implanted in a thawed chicken breast with bones. The presented model allows the simulation of all implant stages of a central catheter. The obtained echogenicity is similar to that observed in human tissue, and the ultrasound identification of the tissues, balloon, needle, wire guide and catheter is feasible and reproducible. The proposed model is simple, economical, easy to manufacture and capable of realistically and effectively simulating an ultrasound-guided venous access.
Udani, Ankeet D; Harrison, T Kyle; Howard, Steven K; Kim, T Edward; Brock-Utne, John G; Gaba, David M; Mariano, Edward R
2012-08-01
A head-mounted display provides continuous real-time imaging within the practitioner's visual field. We evaluated the feasibility of using head-mounted display technology to improve ergonomics in ultrasound-guided regional anesthesia in a simulated environment. Two anesthesiologists performed an equal number of ultrasound-guided popliteal-sciatic nerve blocks using the head-mounted display on a porcine hindquarter, and an independent observer assessed each practitioner's ergonomics (eg, head turning, arching, eye movements, and needle manipulation) and the overall block quality based on the injectate spread around the target nerve for each procedure. Both practitioners performed their procedures without directly viewing the ultrasound monitor, and neither practitioner showed poor ergonomic behavior. Head-mounted display technology may offer potential advantages during ultrasound-guided regional anesthesia.
Anayama, Takashi; Hirohashi, Kentaro; Miyazaki, Ryohei; Okada, Hironobu; Kawamoto, Nobutaka; Yamamoto, Marino; Sato, Takayuki; Orihashi, Kazumasa
2018-01-12
Minimally invasive video-assisted thoracoscopic surgery for small-sized pulmonary nodules is challenging, and image-guided preoperative localisation is required. Near-infrared indocyanine green fluorescence is capable of deep tissue penetration and can be distinguished regardless of the background colour of the lung; thus, indocyanine green has great potential for use as a near-infrared fluorescent marker in video-assisted thoracoscopic surgery. Thirty-seven patients with small-sized pulmonary nodules, who were scheduled to undergo video-assisted thoracoscopic wedge resection, were enrolled in this study. A mixture of diluted indocyanine green and iopamidol was injected into the lung parenchyma as a marker, using either computed tomography-guided percutaneous or bronchoscopic injection techniques. Indications and limitations of the percutaneous and bronchoscopic injection techniques for marking nodules with indocyanine green fluorescence were examined and compared. In the computed tomography-guided percutaneous injection group (n = 15), indocyanine green fluorescence was detected in 15/15 (100%) patients by near-infrared thoracoscopy. A small pneumothorax occurred in 3/15 (20.0%) patients, and subsequent marking was unsuccessful after a pneumothorax occurred. In the bronchoscopic injection group (n = 22), indocyanine green fluorescence was detected in 21/22 (95.5%) patients. In 6 patients who underwent injection marking at 2 different lesion sites, 5/6 (83.3%) markers were successfully detected. Either computed tomography-guided percutaneous or bronchoscopic injection techniques can be used to mark pulmonary nodules with indocyanine green fluorescence. Indocyanine green is a safe and easily detectable fluorescent marker for video-assisted thoracoscopic surgery. Furthermore, the bronchoscopic injection approach enables surgeons to mark multiple lesion areas with less risk of causing a pneumothorax. UMIN-CTR R000027833 accepted by ICMJE. Registered 5 January 2013.
Siribumrungwong, Boonying; Noorit, Pinit; Wilasrusmee, Chumpon; Leelahavarong, Pattara; Thakkinstian, Ammarin; Teerawattananon, Yot
2016-09-01
To conduct economic evaluations of radiofrequency ablation, ultrasound-guided foam sclerotherapy and surgery for great saphenous vein ablation. A cost-utility and cohort analysis from societal perspective was performed to estimate incremental cost-effectiveness ratio. Transitional probabilities were from meta-analysis. Direct medical, direct non-medical, indirect costs, and utility were from standard Thai costings and cohort. Probabilistic sensitivity analysis was performed to assess parameter uncertainties. Seventy-seven patients (31 radiofrequency ablation, 19 ultrasound-guided foam sclerotherapy, and 27 surgeries) were enrolled from October 2011 to February 2013. Compared with surgery, radiofrequency ablation costed 12,935 and 20,872 Baht higher, whereas ultrasound-guided foam sclerotherapy costed 6159 lower and 1558 Bath higher for outpatient and inpatient, respectively. At one year, radiofrequency ablation had slightly lower quality-adjusted life-year, whereas ultrasound-guided foam sclerotherapy yielded additional 0.025 quality-adjusted life-year gained. Because of costing lower and greater quality-adjusted life-year than other compared alternatives, outpatient ultrasound-guided foam sclerotherapy was an option being dominant. Probabilistic sensitivity analysis resulted that at the Thai ceiling threshold of 160,000 Baht/quality-adjusted life-year gained, ultrasound-guided foam sclerotherapy had chances of 0.71 to be cost-effective. Ultrasound-guided foam sclerotherapy seems to be cost-effective for treating great saphenous vein reflux compared to surgery in Thailand at one-year results. © The Author(s) 2015.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Slattery, Michael M.; Goh, Gerard S.; Power, Sarah
PurposeTo prospectively compare the procedural time and complication rates of ultrasound-guided and fluoroscopy-assisted antegrade common femoral artery (CFA) puncture techniques.Materials and MethodsHundred consecutive patients, undergoing a vascular procedure for which an antegrade approach was deemed necessary/desirable, were randomly assigned to undergo either ultrasound-guided or fluoroscopy-assisted CFA puncture. Time taken from administration of local anaesthetic to vascular sheath insertion in the superficial femoral artery (SFA), patients’ age, body mass index (BMI), fluoroscopy radiation dose, haemostasis method and immediate complications were recorded. Mean and median values were calculated and statistically analysed with unpaired t tests.ResultsSixty-nine male and 31 female patients underwent antegrademore » puncture (mean age 66.7 years). The mean BMI was 25.7 for the ultrasound-guided (n = 53) and 25.3 for the fluoroscopy-assisted (n = 47) groups. The mean time taken for the ultrasound-guided puncture was 7 min 46 s and for the fluoroscopy-assisted technique was 9 min 41 s (p = 0.021). Mean fluoroscopy dose area product in the fluoroscopy group was 199 cGy cm{sup 2}. Complications included two groin haematomas in the ultrasound-guided group and two retroperitoneal haematomas and one direct SFA puncture in the fluoroscopy-assisted group.ConclusionUltrasound-guided technique is faster and safer for antegrade CFA puncture when compared to the fluoroscopic-assisted technique alone.« less
CT guided transthoracic catheter drainage of intrapulmonary abscess.
Yunus, Mahira
2009-10-01
To determine the efficacy of CT- guided transthoracic catheter drainage of intrapulmonary abscess considering success rate versus complications. This prospective study was carried out at radiology department of Al-Noor Specialist Hospital, Makkah, Saudi Arabia, from 1.1.2003 to 31.12.2005. Nineteen patients were selected for CT guided percutaneous drainage. Under CT guidance catheter placement was carried out using Seldinger technique. Nineteen patients with lung abscess were selected for the percutaneous CT guided drainage. Eight (42.105%) patients encountered no complications and lung abscess completely resolved with no residual cavity. Five (26.31%) patients developed pneumothorax, which was the most common complication of this study. These patients were kept under observation and followed-up by chest X-rays. Three (15.78%) had mild pneumothorax, which resolved and needed no further management, while two (10.52%) patients developed moderate pneumothorax and chest tube was inserted. Two (10.52%) patients developed mild haemoptysis which resolved within two hours, hence, no further management was required. Two (10.52%) patients had residual cavity and surgery was performed. Congenital cystic adenomatoid malformation (CCAM) was found in both cases. Two patients out of nineteen patients (10.52%) developed bronchopleural fistula and were operated. No mortality occurred during or after the procedure. CT allows optimal placement of catheter and hence enables safe and effective percutaneous evacuation of lung abscess. The morbidity and mortality of patients with percutaneous catheter drainage is lower than with surgical resection. Hence, CT guided drainage should be considered the first therapeutic choice in most patients of lung abscess who do not respond to medical therapy.
Han, Yeji; Kim, Hyun Jung; Kong, Kyoung Ae; Kim, Soo Jung; Lee, Su Hwan; Ryu, Yon Ju; Lee, Jin Hwa; Kim, Yookyoung; Shim, Sung Shine
2018-01-01
Background Advances in bronchoscopy and CT-guided lung biopsy have improved the evaluation of small pulmonary lesions (PLs), leading to an increase in preoperative histological diagnosis. We aimed to evaluate the efficacy and safety of transbronchial lung biopsy using radial endobronchial ultrasound and virtual bronchoscopic navigation (TBLB-rEBUS&VBN) and CT-guided transthoracic needle biopsy (CT-TNB) for tissue diagnosis of small PLs. Methods A systematic search was performed in five electronic databases, including MEDLINE, EMBASE, Cochrane Library Central Register of Controlled Trials, Web of Science, and Scopus, for relevant studies in May 2016; the selected articles were assessed using meta-analysis. The articles were limited to those published after 2000 that studied small PLs ≤ 3 cm in diameter. Results From 7345 records, 9 articles on the bronchoscopic (BR) approach and 15 articles on the percutaneous (PC) approach were selected. The pooled diagnostic yield was 75% (95% confidence interval [CI], 69–80) using the BR approach and 93% (95% CI, 90–96) using the PC approach. For PLs ≤ 2 cm, the PC approach (pooled diagnostic yield: 92%, 95% CI: 88–95) was superior to the BR approach (66%, 95% CI: 55–76). However, for PLs > 2 cm but ≤ 3 cm, the diagnostic yield using the BR approach was improved to 81% (95% CI, 75–85). Complications of pneumothorax and hemorrhage were rare with the BR approach but common with the PC approach. Conclusions CT-TNB was superior to TBLB-rEBUS&VBN for the evaluation of small PLs. However, for lesions greater than 2 cm, the BR approach may be considered considering its diagnostic yield of over 80% and the low risk of procedure-related complications. PMID:29357388
Chiu, Chee Kidd; Chan, Chris Yin Wei; Kwan, Mun Keong
2017-01-01
This study investigates the safety and accuracy of percutaneous pedicle screws placed using fluoroscopic guidance in the thoracolumbosacral spine among Asian patients. Computerized tomography scans of 128 patients who had surgery using fluoroscopic-guided percutaneous pedicle screws were selected. Medial, lateral, superior, and inferior screw perforations were classified into grade 0 (no violation), grade 1 (<2 mm perforation), grade 2 (2-4 mm perforation), and grade 3(>4 mm perforation). Anterior perforations were classified into grade 0 (no violation), grade 1 (<4 mm perforation), grade 2 (4-6 mm perforation), and grade 3(>6 mm perforation). Grade 2 and grade 3 perforation were considered as "critical" perforation. In total, 1002 percutaneous pedicle screws from 128 patients were analyzed. The mean age was 52.7 ± 16.6. There were 70 male patients and 58 female patients. The total perforation rate was 11.3% (113) with 8.4% (84) grade 1, 2.6% (26) grade 2, and 0.3% (3) grade 3 perforations. The overall "critical" perforation rate was 2.9% (29 screws) and no complications were noted. The highest perforation rates were at T4 (21.6%), T2 (19.4%), and T6 (19.2%). The total perforation rate of 11.3% with the total "critical" perforation rate of 2.9% (2.6% grade 2 and 0.3% grade 3 perforations). The highest perforation rates were found over the upper to mid-thoracic region. Fluoroscopic-guided percutaneous pedicle screws insertion among Asians has the safety and accuracy comparable to the current reported percutaneous pedicle screws and open pedicle screws techniques.
GU, SI-PING; YOU, ZHI-YUAN; HUANG, YUNTENG; LU, YI-JIN; HE, CAOHUI; CAI, XIAO-DONG; ZHOU, XIAO-MING
2013-01-01
The aim of this study was to investigate the effectiveness of minimally invasive percutaneous cystostomy with ureteroscopic pneumatic lithotripsy for treating calculus in bladder diverticula. Percutaneous cystostomy with ureteroscopic pneumatic lithotripsy was performed on six elderly male patients with calculi in bladder diverticula, who could not be treated with transurethral ureteroscopic lithotripsy. The stones were successfully removed from all patients, with no complications such as bladder perforation, rupture, urethritis or cystitis. The surgery time was 15–60 min, with an average time of 32 min. Postoperative ultrasound or X-ray examination showed no stone residues and the bladder stoma healed well. No recurrent stones were detected in the follow-up of 3–24 months (average, 16 months). Minimally invasive percutaneous cystostomy with ureteroscopic pneumatic lithotripsy is a safe, efficient and easy treatment for calculus in bladder diverticula. This method provides a new clinical approach for lithotripsy and we suggest that it is worthy of wider use. PMID:23837044
NASA Astrophysics Data System (ADS)
Kim, Younsu; Kim, Sungmin; Boctor, Emad M.
2017-03-01
An ultrasound image-guided needle tracking systems have been widely used due to their cost-effectiveness and nonionizing radiation properties. Various surgical navigation systems have been developed by utilizing state-of-the-art sensor technologies. However, ultrasound transmission beam thickness causes unfair initial evaluation conditions due to inconsistent placement of the target with respect to the ultrasound probe. This inconsistency also brings high uncertainty and results in large standard deviations for each measurement when we compare accuracy with and without the guidance. To resolve this problem, we designed a complete evaluation platform by utilizing our mid-plane detection and time of flight measurement systems. The evaluating system uses a PZT element target and an ultrasound transmitting needle. In this paper, we evaluated an optical tracker-based surgical ultrasound-guided navigation system whereby the optical tracker tracks marker frames attached on the ultrasound probe and the needle. We performed ten needle trials of guidance experiment with a mid-plane adjustment algorithm and with a B-mode segmentation method. With the midplane adjustment, the result showed a mean error of 1.62+/-0.72mm. The mean error increased to 3.58+/-2.07mm without the mid-plane adjustment. Our evaluation system can reduce the effect of the beam-thickness problem, and measure ultrasound image-guided technologies consistently with a minimal standard deviation. Using our novel evaluation system, ultrasound image-guided technologies can be compared under equal initial conditions. Therefore, the error can be evaluated more accurately, and the system provides better analysis on the error sources such as ultrasound beam thickness.
Ultrasound-guided suprascapular nerve block: a correlation with fluoroscopic and cadaveric findings.
Peng, Philip W H; Wiley, Michael J; Liang, James; Bellingham, Geoff A
2010-02-01
Previous work on the ultrasound-guided injection technique and the sonoanatomy of the suprascapular region relevant to the suprascapular nerve (SSN) block suggested that the ultrasound scan showed the presence of the suprascapular notch and transverse ligament. The intended target of the ultrasound-guided injection was the notch. The objective of this case report and the subsequent cadaver dissection findings is to reassess the interpretation of the ultrasound images when locating structures for SSN block. A 45-yr-old man with chronic shoulder pain received an ultrasound-guided SSN block using the suprascapular notch as the intended target. The position of the needle was verified by fluoroscopy, which showed the tip of the needle well outside the suprascapular notch. Similar ultrasound-guided SSN blocks were performed in two cadavers. Dissections were performed which showed that the needle tips were not at the suprascapular notch but, more accurately, were close to the SSN but at the floor of the suprascapular fossa between the suprascapular and spinoglenoid notch. Our fluoroscopic and cadaver dissection findings both suggest that the ultrasound image of the SSN block shown by the well-described technique is actually targeting the nerve on the floor of the suprascapular spine between the suprascapular and spinoglenoid notches rather than the suprascapular notch itself. The structure previously identified as the transverse ligament is actually the fascia layer of the supraspinatus muscle.
Ultrasound-guided peripheral nerve blockade.
Chin, Ki Jinn; Chan, Vincent
2008-10-01
The use of ultrasound for peripheral nerve blockade is becoming popular. Although the feasibility of ultrasound-guided nerve blockade is now clear, it is uncertain at this time whether it represents the new standard for regional anesthesia in terms of efficacy and safety. The ability to visualize nerve location, needle advancement, needle-nerve interaction, and local anesthetic spread makes ultrasound-guided nerve block an attractive option. Study results indicate that these advantages can improve the ease of block performance, block success rates, and complications. At the same time there is evidence that ultrasound-guided regional anesthesia is a unique skill in its own right, and that proficiency in it requires training and experience. Ultrasound is a valuable tool that is now available to the regional anesthesiologist, and it is fast becoming a standard part of practice. It promises to be of especial value to the less experienced practitioner. Ultrasound does not in itself, however, guarantee the efficacy and safety of peripheral nerve blockade. Proper training in its use is required and we can expect to see the development of formal standards and guidelines in this regard.
Multi-Frequency Intravascular Ultrasound (IVUS) Imaging
Ma, Teng; Yu, Mingyue; Chen, Zeyu; Fei, Chunlong; Shung, K. Kirk; Zhou, Qifa
2015-01-01
Acute coronary syndrome (ACS) is frequently associated with the sudden rupture of a vulnerable atherosclerotic plaque within the coronary artery. Several unique physiological features, including a thin fibrous cap accompanied by a necrotic lipid core, are the targeted indicators for identifying the vulnerable plaques. Intravascular ultrasound (IVUS), a catheter-based imaging technology, has been routinely performed in clinics for more than 20 years to describe the morphology of the coronary artery and guide percutaneous coronary interventions. However, conventional IVUS cannot facilitate the risk assessment of ACS because of its intrinsic limitations, such as insufficient resolution. Renovation of the IVUS technology is essentially needed to overcome the limitations and enhance the coronary artery characterization. In this paper, a multi-frequency intravascular ultrasound (IVUS) imaging system was developed by incorporating a higher frequency IVUS transducer (80 to 150 MHz) with the conventional IVUS (30–50 MHz) system. The newly developed system maintains the advantage of deeply penetrating imaging with the conventional IVUS, while offering an improved higher resolution image with IVUS at a higher frequency. The prototyped multi-frequency catheter has a clinically compatible size of 0.95 mm and a favorable capability of automated image co-registration. In vitro human coronary artery imaging has demonstrated the feasibility and superiority of the multi-frequency IVUS imaging system to deliver a more comprehensive visualization of the coronary artery. This ultrasonic-only intravascular imaging technique, based on a moderate refinement of the conventional IVUS system, is not only cost-effective from the perspective of manufacturing and clinical practice, but also holds the promise of future translation into clinical benefits. PMID:25585394
Current status of percutaneous coronary intervention of chronic total occlusion
Ge, Jun-bo
2012-01-01
This paper describes the current status of percutaneous coronary intervention (PCI) for totally occluded coronary arteries. Chronic total occlusion is associated with 10%–20% of all PCI procedures. Results show that opening an occluded vessel, especially one supplying a considerable area of myocardium, may be beneficial for a patient’s angina relief and heart function. We describe the devices used currently in re-canalization such as new wires, microcatheters (including Tonus and Cosair) and intravascular ultrasound guidance. Different techniques to improve the success rate and reduce complications are discussed in detail. PMID:22843178
Kumar, Abhishek; Sheikh, Ahmed; Partyka, Luke; Contractor, Sohail
2014-01-01
A 45-year-old woman status post laparoscopic cholecystectomy 3years ago presented with upper gastrointestinal bleeding. Endoscopy revealed hemobilia. Computed tomographic abdomen demonstrated a 2-cm aneurysm in the gall bladder fossa, consistent with a pseudoaneurysm. Initially, transcatheter coil embolization was attempted but recanalization of the aneurysm with recurrent bleeding in 2 days ensued. The aneurysm was then accessed percutaneously under ultrasound guidance and thrombin was injected into the aneurysm with subsequent complete thrombosis of the aneurysm and cessation of bleeding. Copyright © 2014 Elsevier Inc. All rights reserved.
The development of laser surgery and medicine in China
NASA Astrophysics Data System (ADS)
Chen, Mingzhe
2005-07-01
The first Chinese ruby laser was created in 1961 and it was adopted for the retina coagulation experiment in 1965. Since 1970's, lasers had been widely applied clinically including the diseases suitable to physical therapy or acupuncture. The Chinese HpD was first produced in 1981 and first case of PDT was treated using Chinese HpD and Chinese lasers in the same year. Its success brought attention establishing a research group supported by the government in 1982. A nationwide systemic research project on PDT was then carried out. The step taken for PDT also accelerated the development of various fields of laser medicine and surgery. Laser treatments had been commonly adopted in the clinics and hospitals for the diseases of the superficial lesions and the lesions can be reached by the endoscopes non-invasively in 1980's. Since 1990's, the interventional laser therapies adopted mainly were percutaneous laser angioplasty, laser treatments through laparoscope, thoracoscope, arthroscope, neuro-endoscope etc. Ultrasound guided percutaneous laser heat coagulation for small hepatic cancer revealed good results and ultrasound guided percutaneous PDT for advanced large liver cancer revealed unexpected results after five years follow-up. At present: There are more long-term follow-up patients in the clinical trial; more advanced commercial available lasers and new techniques are adopted. Since the popularization of scanning electron microscope, laser scanning confocal microscope, laser induced auto-fluorescence system, high sensitivity fluorescence microscopic imaging system etc. in the laboratories, the basic studies can be more advanced and some times, the sub-cellular level can be reached; ultra-structure histo-morphology and gene studies are involved. In dermatology, Q-switched Alexandrite laser and other Q-switched lasers are used mainly for the treatment of skin pigmentation and vascular diseases; pulsed dye laser, ultra-pulsed CO2 laser are used in resurfacing, facial acne scar, osmidrosis etc. For ophthalmology, excimer laser are used for myopia or hyperopia; argon green laser, krypton yellow laser are adopted in coagulation for retinal detachment and neovascularization etc. Lasers are often used for the canaliculoplasty in the lacrimal canal. Low level lasers had been used very often on the acupuncture points and for many chronic diseases. Intravascular low level laser irradiation adopting semiconductor lasers and He-Ne laser were reported to use for comatose patients, schizophrenia, vascular dementia, Alzeimer"s disease and coronary disease. Reports from laboratory studies in the field of low level laser demonstrated the stimulation effect on the cells and immunology system; inhibitory effect on proliferation; it improved the biomedical data in hemorrheology; promoted the spinal motor nerve cell function, axonal regeneration; increased epidermal Langerhams cell to improve the antigen function, increased myocardial capillary permeability. Intra-coronary low power red laser irradiation assisted coronary interventional therapy showed its prevention effect on restenosis. Studies about the effects of various kinds of lasers, their wavelength, power densities and doses on various kinds of tissues were reported.
Diolaiuti, Sara; Iizuka, Tateyuki; Schroth, Gerhard; Remonda, Luca; Laedrach, Kurt; El-Koussy, Marwan; Frueh, Beatrice E; Goldblum, David
2009-03-01
To report the efficacy of percutaneous treatment of an orbital venous malformation with an electrolytically detachable fibred coil. We report an instance of radiography-guided percutaneous treatment with an electrolytically detachable fibred coil in a 16-year-old boy with acute, spontaneous, painless proptosis on the left side, which progressed with time. Magnetic resonance imaging, angiography and orbitophlebography revealed a low-flow, intraorbital venous malformation. Percutaneous puncture and drainage were followed by a short remission. Following an acute recurrence, a single detachable fibred coil was deployed via a percutaneous approach under angiographic guidance. No radiological or clinical recurrences were observed over 4 years. Embolization of a deep orbital venous malformation with detachable fibred coils via a percutaneous approach can be highly effective, and may be considered before proceeding with open surgery.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Garnon, Julien, E-mail: juliengarnon@gmail.com; Koch, Guillaume, E-mail: Guillaume.koch@gmail.com; Ramamurthy, Nitin, E-mail: Nitin-ramamurthy@hotmail.com
ObjectiveTo review our initial experience with percutaneous CT and fluoroscopy-guided screw fixation of pathological shoulder-girdle fractures.Materials and MethodsBetween May 2014 and June 2015, three consecutive oncologic patients (mean age 65 years; range 57–75 years) with symptomatic pathological shoulder-girdle fractures unsuitable for surgery and radiotherapy underwent percutaneous image-guided screw fixation. Fractures occurred through metastases (n = 2) or a post-ablation cavity (n = 1). Mechanical properties of osteosynthesis were adjudged superior to stand-alone cementoplasty in each case. Cannulated screws were placed under combined CT and fluoroscopic guidance with complementary radiofrequency ablation or cementoplasty to optimise local palliation and secure screw fixation, respectively, in two cases. Follow-up wasmore » undertaken every few weeks until mortality or most recent appointment.ResultsFour pathological fractures were treated in three patients (2 acromion, 1 clavicular, 1 coracoid). Mean size of associated lesion was 2.6 cm (range 1–4.5 cm). Technical success was achieved in all cases (100 %), without complications. Good palliation and restoration of mobility were observed in two cases at 2–3 months; one case could not be followed due to early post-procedural oncologic mortality.ConclusionPercutaneous image-guided shoulder-girdle osteosynthesis appears technically feasible with good short-term efficacy in this complex patient subset. Further studies are warranted to confirm these promising initial results.« less
Izumo, Takehiro; Matsumoto, Yuji; Sasada, Shinji; Chavez, Christine; Nakai, Toshiyuki; Tsuchida, Takaaki
2017-03-01
The utility of rapid on-site evaluation during endobronchial ultrasound with a guide sheath for peripheral pulmonary lesions is unclear. The aim of this study was to evaluate the role of rapid on-site evaluation during endobronchial ultrasound with a guide sheath for peripheral pulmonary lesions. Consecutive patients who underwent endobronchial ultrasound with a guide sheath for the diagnosis of peripheral pulmonary lesions at our hospital between September 2012 and July 2014 were included in this retrospective study. Cytology slides were air-dried, and modified Giemsa (Diff-Quik) staining was used for rapid on-site evaluation. Additional smears were prepared for Papanicolaou staining and tissue samples were placed in formalin for histologic evaluation. The results of rapid on-site evaluation were compared with the final diagnoses of endobronchial ultrasound with a guide sheath. A total of 718 cases were included in the study population. The sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy of rapid on-site evaluation during endobronchial ultrasound with a guide sheath for peripheral pulmonary lesions was 88.6%, 65.9%, 81.2%, 77.7% and 80.1%, respectively. There were no procedure-related deaths. Rapid on-site evaluation during endobronchial ultrasound with a guide sheath had high sensitivity for peripheral pulmonary lesions. When carrying out rapid on-site evaluation of transbronchial biopsy samples from peripheral pulmonary lesions, careful interpretation and clinical correlation are necessary. © The Author 2016. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com
Suzuki, Rei; Irisawa, Atsushi; Bhutani, Manoop S; Hikichi, Takuto; Takagi, Tadayuki; Shibukawa, Goro; Sato, Ai; Sato, Masaki; Ikeda, Tsunehiko; Watanabe, Ko; Nakamura, Jun; Annangi, Srinadh; Tasaki, Kazuhiro; Obara, Katsutoshi; Ohira, Hiromasa
2014-01-01
AIM: To evaluate the feasibility of using an automated spring-loaded needle device for endoscopic ultrasound (EUS)-guided abdominal paracentesis (EUS-P) to see if this would make it easier to puncture the mobile and lax gastric wall for EUS-P. METHODS: The EUS database and electronic medical records at Fukushima Medical University Hospital were searched from January 2001 to April 2011. Patients with a history of cancer and who underwent EUS-P using an automated spring-loaded needle device with a 22-gauge puncture needle were included. The needle was passed through the instrument channel and advanced through the gastrointestinal wall under EUS guidance into the echo-free space in the abdominal cavity and ascitic fluid was collected. The confirmed diagnosis of malignant ascites included positive cytology and results from careful clinical observation for at least 6 mo in patients with negative cytology. The technical success rate, cytology results and complications were evaluated. RESULTS: We found 11 patients who underwent EUS-P with an automated spring-loaded needle device. In 4 cases, ascites was revealed only with EUS but not in other imaging modalities. EUS-P was done in 7 other cases because there was minimal ascitic fluid and no safe window for percutaneous abdominal aspiration. Ascitic fluid was obtained in all cases by EUS-P. The average amount aspirated was 14.1 mL (range 0.5-38 mL) and that was sent for cytological exam. The etiology of ascitic fluid was benign in 5 patients and malignant in 6. In all cases, ascitic fluid was obtained with the first needle pass. No procedure-related adverse effects occurred. CONCLUSION: EUS-P with an automated spring-loaded needle device is a feasible and safe method for ascites evaluation. PMID:24567793
Improving Echo-Guided Procedures Using an Ultrasound-CT Image Fusion System.
Diana, Michele; Halvax, Peter; Mertz, Damien; Legner, Andras; Brulé, Jean-Marcel; Robinet, Eric; Mutter, Didier; Pessaux, Patrick; Marescaux, Jacques
2015-06-01
Image fusion between ultrasound (US) and computed tomography (CT) scan or magnetic resonance can increase operator accuracy in targeting liver lesions, particularly when those are undetectable with US alone. We have developed a modular gel to simulate hepatic solid lesions for educational purposes in imaging and minimally invasive ablation techniques. We aimed to assess the impact of image fusion in targeting artificial hepatic lesions during the hands-on part of 2 courses (basic and advanced) in hepatobiliary surgery. Under US guidance, 10 fake tumors of various sizes were created in the livers of 2 pigs, by percutaneous injection of a biocompatible gel engineered to be hyperdense on CT scanning and barely detectable on US. A CT scan was obtained and a CT-US image fusion was performed using the ACUSON S3000 US system (Siemens Healthcare, Germany). A total of 12 blinded course attendants, were asked in turn to perform a 10-minute liver scan with US alone followed by a 10-minute scan using image fusion. Using US alone, the expert managed to identify all lesions successfully. The true positive rate for course attendants with US alone was 14/36 and 2/24 in the advanced and basic courses, respectively. The total number of false positives identified was 26. With image fusion, the rate of true positives significantly increased to 31/36 (P < .001) in the advanced group and 16/24 in the basic group (P < .001). The total number of false positives, considering all participants, decreased to 4 (P < .001). Image fusion significantly increases accuracy in targeting hepatic lesions and might improve echo-guided procedures. © The Author(s) 2015.
Ultrasound-guided interventional PDT of liver cancer
NASA Astrophysics Data System (ADS)
Zeng, Chaoying; Yang, Dong; Huang, Ping; Zhang, Huijuan; Huang, Muyin; Chen, Ji; Lu, Guorong
1996-09-01
Thirty patients with advanced liver cancer were treated by interstitial photodynamic therapy (PDT). These included 28 hepatocellular carcinoma and two adenocarcinoma, 19 primary tumors and 11 recurred follow other treatments. The diameter of tumors were 7-10cm in 13 cases and 10-16cm in 17 cases. In this study, an argon laser pumped dye laser system was used to give a CW laser beam at 630 nm which was split and coupled into there optical fibers. The patients were injected intravenously with photosensitizer hematoporphyrin derivative at a dose of 5mg/kg body weight 48 hours before PDT. Then the fibers were inserted into tumor by ultrasound- guided percutaneous puncture. The inserted irradiation points were spaced in entire tumor with the light release power 300mW and the irradiation time 12 minutes per point. Total 52 treatments were performed in 30 patients. Among them, 14 cases were treated only one time and 16 cases via 2-3 times. The follow-up was carried out in 25 cases for 12- 24 months. The results show that significant remission was 22 percent in those patients by only one treatment and 62 percent in those via 2 to 3 treatments. The shrink rate of tumor size was over 90 percent in five of six cases after treatment 3. The survival time has been over one year in 12 cases. No obvious change to be found for all patients in liver function test, renal function test and blood routine examination. The level of AFP indicated a descending trend after PDT. This work indicate that PDT is effective and safe for the treatment of large liver cancers including those recurred follow hepatic resection and those failed in hepatic artery infusion embolic chemotherapy.
Burgess, Alison; Dubey, Sonam; Yeung, Sharon; Hough, Olivia; Eterman, Naomi; Aubert, Isabelle; Hynynen, Kullervo
2014-12-01
To validate whether repeated magnetic resonance (MR) imaging-guided focused ultrasound treatments targeted to the hippocampus, a brain structure relevant for Alzheimer disease ( AD Alzheimer disease ), could modulate pathologic abnormalities, plasticity, and behavior in a mouse model. All animal procedures were approved by the Animal Care Committee and are in accordance with the Canadian Council on Animal Care. Seven-month-old transgenic (TgCRND8) (Tg) mice and their nontransgenic (non-Tg) littermates were entered in the study. Mice were treated weekly with MR imaging-guided focused ultrasound in the bilateral hippocampus (1.68 MHz, 10-msec bursts, 1-Hz burst repetition frequency, 120-second total duration). After 1 month, spatial memory was tested in the Y maze with the novel arm prior to sacrifice and immunohistochemical analysis. The data were compared by using unpaired t tests and analysis of variance with Tukey post hoc analysis. Untreated Tg mice spent 61% less time than untreated non-Tg mice exploring the novel arm of the Y maze because of spatial memory impairments (P < .05). Following MR imaging-guided focused ultrasound, Tg mice spent 99% more time exploring the novel arm, performing as well as their non-Tg littermates. Changes in behavior were correlated with a reduction of the number and size of amyloid plaques in the MR imaging-guided focused ultrasound-treated animals (P < .01). Further, after MR imaging-guided focused ultrasound treatment, there was a 250% increase in the number of newborn neurons in the hippocampus (P < .01). The newborn neurons had longer dendrites and more arborization after MR imaging-guided focused ultrasound, as well (P < .01). Repeated MR imaging-guided focused ultrasound treatments led to spatial memory improvement in a Tg mouse model of AD Alzheimer disease . The behavior changes may be mediated by decreased amyloid pathologic abnormalities and increased neuronal plasticity. © RSNA, 2014.
Updates on Percutaneous Radiologic Gastrostomy/Gastrojejunostomy and Jejunostomy
Park, Auh-Whan
2010-01-01
Gastrostomy placement for nutritional support for patients with inadequate oral intake has been attempted using surgical, endoscopic, and, more recently, percutaneous radiologically guided methods. Surgical gastrostomy has been superseded by both endoscopic and radiologic gastrostomy. We describe herein the indications, contraindications, patient preparations, techniques, complications, and aftercare with regard to radiologic gastrostomy. In addition, we discuss the available tube types and their perceived advantages. There remain some controversies regarding gastropexy performance and primary percutaneous gastrojejunostomy. Percutaneous jejunostomy is indicated for patients whose stomach is inaccessible for gastrostomy placement or for those who have had a previous gastrectomy. PMID:21103291
Percutaneous Relief of Tension Pneumomediastinum in a Child
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chau, Helen Hoi-lun; Kwok, Philip Chong-hei; Lai, Albert Kwok-hung
2003-11-15
The purpose of this article was to describe the experience of relieving tension pneumomediastinum by a fluoroscopic-guided percutaneous method. We inserted a percutaneous drainage catheter with a Heimlich valve under fluoroscopic guidance to relieve the tension pneumomediastinum in a 2-year-old girl who suffered from dermatomyositis with lung involvement. This allowed immediate relief without the need for surgery. The procedure was repeated for relapsed tension pneumomediastinum. Good immediate results were achieved in each attempt. We conclude that percutaneous relief of pneumomediastinum under fluoroscopic guidance can be performed safely and rapidly in patients not fit for surgery.
Percutaneous Direct Puncture Embolization with N-butyl-cyanoacrylate for High-flow Priapism
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tokue, Hiroyuki, E-mail: tokue@s2.dion.ne.jp; Shibuya, Kei; Ueno, Hiroyuki
There are many treatment options in high-flow priapism. Those mentioned most often are watchful waiting, Doppler-guided compression, endovascular highly selective embolization, and surgery. We present a case of high-flow priapism in a 57-year-old man treated by percutaneous direct puncture embolization of a post-traumatic left cavernosal arteriovenous fistula using N-butyl-cyanoacrylate. Erectile function was preserved during a 12-month follow-up. No patients with percutaneous direct puncture embolization for high-flow priapism have been reported previously. Percutaneous direct puncture embolization is a potentially useful and safe method for management of high-flow priapism.
2015-10-01
imaging can be used to guide dissection. We have also successfully integrated a programmable ultrasound machine (Verasonics Vantage ) and tunable pulsed...Mobile HE) with the programmable ultrasound machine (Verasonics Vantage ). We have synchronized the signals to enable interleaved acquisition of US
Ultrasound in regional anaesthesia.
Griffin, J; Nicholls, B
2010-04-01
Ultrasound guidance is rapidly becoming the gold standard for regional anaesthesia. There is an ever growing weight of evidence, matched with improving technology, to show that the use of ultrasound has significant benefits over conventional techniques, such as nerve stimulation and loss of resistance. The improved safety and efficacy that ultrasound brings to regional anaesthesia will help promote its use and realise the benefits that regional anaesthesia has over general anaesthesia, such as decreased morbidity and mortality, superior postoperative analgesia, cost-effectiveness, decreased postoperative complications and an improved postoperative course. In this review we consider the evidence behind the improved safety and efficacy of ultrasound-guided regional anaesthesia, before discussing its use in pain medicine, paediatrics and in the facilitation of neuraxial blockade. The Achilles' heel of ultrasound-guided regional anaesthesia is that anaesthetists are far more familiar with providing general anaesthesia, which in most cases requires skills that are achieved faster and more reliably. To this ends we go on to provide practical advice on ultrasound-guided techniques and the introduction of ultrasound into a department.
Xiu, Jiancheng; Chen, Gangbin; Zheng, Hua; Wang, Yuegang; Chen, Haibin; Liu, Xuewei; Wu, Juefei; Bin, Jianping
2016-02-01
Fractional flow reserve (FFR)-guided percutaneous coronary intervention (PCI) is used to assess the need for angioplasty in vessels with intermediate blockages. The treatment outcomes of FFR-guided vs. conventional angiography-guided PCI were evaluated in patients with multi-vessel coronary artery disease (CAD). Prospective and retrospective studies comparing FFR-guided vs. angiography-guided PCI in patients with multi-vessel CAD were identified from medical databases by two independent reviewers using the terms "percutaneous coronary intervention, fractional flow reserve, angiography, coronary heart disease, major adverse cardiac events (MACE) and myocardial infarction". The primary outcome was the number of stents placed, and the secondary outcomes were procedure time, mortality, myocardial infarction (MI) and MACE rates. Seven studies (three retrospective and four prospective), which included 49,517 patients, were included in this review. A total of 4,755 patients underwent FFR, while 44,697 received angiography-guided PCI. The mean patient age ranged from 58 to 71.7 years. The average number of stents used in FFR patients ranged from 0.3-1.9, and in angiography-guided PCI patients ranged from 0.7-2.7. Analysis indicated there was a greater number of stents placed in the angiography-guided group compared with the FFR group (pooled difference in means: -0.64, 95% confidence interval [CI]: -0.81 to -0.47, P < 0.001). There were no differences in the secondary outcomes between the two groups. Both procedures produce similar clinical outcomes, but the fewer number of stents used with FFR may have clinical as was as cost implications.
Intraoperative Ultrasound for Peripheral Nerve Applications.
Willsey, Matthew; Wilson, Thomas J; Henning, Phillip Troy; Yang, Lynda J-S
2017-10-01
Offering real-time, high-resolution images via intraoperative ultrasound is advantageous for a variety of peripheral nerve applications. To highlight the advantages of ultrasound, its extraoperative uses are reviewed. The current intraoperative uses, including nerve localization, real-time evaluation of peripheral nerve tumors, and implantation of leads for peripheral nerve stimulation, are reviewed. Although intraoperative peripheral nerve localization has been performed previously using guide wires and surgical dyes, the authors' approach using ultrasound-guided instrument clamps helps guide surgical dissection to the target nerve, which could lead to more timely operations and shorter incisions. Copyright © 2017 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Ries, Mario; de Senneville, Baudouin Denis; Regard, Yvan; Moonen, Chrit
2012-11-01
The objective of this study is to evaluate the feasibility to integrate ultrasound echography as an additional imaging modality for continuous target tracking, while performing simultaneously real-time MR- thermometry to guide a High Intensity Focused Ultrasound (HIFU) ablation. Experiments on a moving phantom were performed with MRI-guided HIFU during continuous ultrasound echography. Real-time US echography-based target tracking during MR-guided HIFU heating was performed with heated area dimensions similar to those obtained for a static target. The combination of both imaging modalities shows great potential for real-time beam steering and MR-thermometry.
Wiesner, E L; Hillen, T J; Long, J; Jennings, J W
2018-05-01
Cervical spine biopsies can be challenging due to the anatomy and the adjacent critical structures. Percutaneous image-guided biopsies can obviate the need for an open biopsy, however there have been few studies looking at the approaches, safety, and efficacy of percutaneous cervical spine biopsies. This retrospective study evaluated technical considerations, histopathologic and microbiologic yield, and safety in CT-guided cervical bone biopsies. A retrospective review of cervical bone and/or bone/disc biopsies performed from January 2010 to January 2017 was included in this study. Clinical diagnosis and indication, patient demographics, biopsy location, biopsy needle type, technical approach, lesion size, dose-length product, conscious sedation details, complications, and diagnostic histopathologic and/or microbiologic yield were recorded for each case and summarized. A total of 73 patients underwent CT-guided cervical bone biopsies. Fifty-three percent (39/73) were for clinical/imaging concern for infection and 47% (34/73) were for primary tumors or metastatic disease. Thirty-four percent (25/73) were of the inferior cervical spine (ie, C6 and C7). A sufficient sample was obtained for histopathologic and microbiologic analyses in 96% (70/73) of the biopsies. Forty-six percent (18/39) of those samples taken for infection had positive cultures. Two intraprocedural complications occurred in which the patients became hypotensive during the procedure without long-term complications. Percutaneous CT-guided biopsy of the cervical spine is an effective and safe procedure with high diagnostic yield and can obviate open procedures for histopathologic and microbiologic analyses of patients with clinical and imaging findings concerning for infection or primary and metastatic osseous lesions. © 2018 by American Journal of Neuroradiology.
Accuracy of ultrasound-guided nerve blocks of the cervical zygapophysial joints.
Siegenthaler, Andreas; Mlekusch, Sabine; Trelle, Sven; Schliessbach, Juerg; Curatolo, Michele; Eichenberger, Urs
2012-08-01
Cervical zygapophysial joint nerve blocks typically are performed with fluoroscopic needle guidance. Descriptions of ultrasound-guided block of these nerves are available, but only one small study compared ultrasound with fluoroscopy, and only for the third occipital nerve. To evaluate the potential usefulness of ultrasound-guidance in clinical practice, studies that determine the accuracy of this technique using a validated control are essential. The aim of this study was to determine the accuracy of ultrasound-guided nerve blocks of the cervical zygapophysial joints using fluoroscopy as control. Sixty volunteers were studied. Ultrasound-imaging was used to place the needle to the bony target of cervical zygapophysial joint nerve blocks. The levels of needle placement were determined randomly (three levels per volunteer). After ultrasound-guided needle placement and application of 0.2 ml contrast dye, fluoroscopic imaging was performed for later evaluation by a blinded pain physician and considered as gold standard. Raw agreement, chance-corrected agreement κ, and chance-independent agreement Φ between the ultrasound-guided placement and the assessment using fluoroscopy were calculated to quantify accuracy. One hundred eighty needles were placed in 60 volunteers. Raw agreement was 87% (95% CI 81-91%), κ was 0.74 (0.64-0.83), and Φ 0.99 (0.99-0.99). Accuracy varied significantly between the different cervical nerves: it was low for the C7 medial branch, whereas all other levels showed very good accuracy. Ultrasound-imaging is an accurate technique for performing cervical zygapophysial joint nerve blocks in volunteers, except for the medial branch blocks of C7.
Pacella, John J.; Brands, Judith; Schnatz, Frederick G.; Black, John J.; Chen, Xucai; Villanueva, Flordeliza S.
2015-01-01
Despite epicardial coronary artery reperfusion by percutaneous coronary intervention, distal micro-embolization into the coronary microcirculation limits myocardial salvage during acute myocardial infarction. Thrombolysis using ultrasound and microbubbles (sonothrombolysis) is an approach that induces microbubble oscillations to cause clot disruption and restore perfusion. We sought to determine whether this technique could restore impaired tissue perfusion caused by thrombotic microvascular obstruction. In 16 rats, an imaging transducer was placed on the biceps femoris muscle, perpendicular to a single-element 1-MHz treatment transducer. Ultrasound contrast perfusion imaging was performed at baseline and after micro-embolization. Therapeutic ultrasound (5000 cycles, pulse repetition frequency = 5 0.33 Hz, 1.5 MPa) was delivered to nine rats for two 10-min sessions during intra-arterial infusion of lipid-encapsulated microbubbles; seven control rats received no ultrasound–microbubble therapy. Ultrasound contrast perfusion imaging was repeated after each treatment or control period, and microvascular volume was measured as peak video intensity. There was a 90% decrease in video intensity after micro-embolization (from 8.6 ± 4.8 to 0.7 ± 0.8 dB, p < 0.01). The first and second ultrasound–microbubble sessions were respectively followed by video intensity increases of 5.8 ± 5.1 and 8.7 ± 5.7 dB (p < 0.01, compared with micro-embolization). The first and second control sessions, respectively, resulted in no significant increase in video intensity (2.4 ± 2.3 and 3.6 ± 4.9) compared with micro-embolization (0.6 ± 0.7 dB). We have developed an in vivo model that simulates the distal thrombotic microvascular obstruction that occurs after primary percutaneous coronary intervention. Long-pulse-length ultrasound with microbubbles has a therapeutic effect on microvascular perfusion and may be a valuable adjunct to reperfusion therapy for acute myocardial infarction. PMID:25542487
Focused Ultrasound Surgery for Uterine Fibroids
... ultrasound surgery, your doctor may perform a pelvic magnetic resonance imaging (MRI) scan before treatment. Focused ultrasound surgery — also called magnetic resonance-guided focused ultrasound surgery or focused ultrasound ...
De Boo, Diederick W; Mott, Nigel; Tregaskis, Peter; Quach, Trung; Menahem, Solomon; Walker, Rowan G; Koukounaras, Jim
2015-12-01
Various methods of peritoneal dialysis (PD) catheter insertion are available. The purpose of this study was to evaluate a percutaneous insertion technique using ultrasound (US) and fluoroscopy performed under conscious sedation and as day case procedure. Data of 87 percutaneous inserted dialysis catheters were prospectively collected, including patients' age, gender, body mass index, history of previous abdominal surgery and cause of end stage renal failure. Length of hospital stay, early complications and time to first use were also recorded. Institutional review board approval was obtained. A 100% technical success rate was observed. Early complications included bleeding (n = 3), catheter dysfunction (n = 6), exit site infection (n = 1) and exit site leakage (n = 1). All cases of catheter dysfunction and one case of bleeding required surgical revision. Median time of follow-up was 18 months (range 3-35), and median time from insertion to first use was days 14 (1-47). Of the 82 patients who started dialysis, 20 (23%) ceased PD at some stage during follow-up. Most frequently encountered reasons include deteriorating patient cognitive or functional status (n = 5), successful transplant kidney (n = 4) and pleuro-peritoneal fistula (n = 4). Sixty-two (71%) PD catheter insertions were performed as day case. The remaining insertions were performed on patients already admitted to the hospital. Percutaneous insertion of dialysis catheter using US and fluoroscopy is not only safe but can be performed as day case procedure in most patients, even with a medical history of abdominal surgery and/or obesity. © 2015 The Royal Australian and New Zealand College of Radiologists.
Bhattacharjee, Sulagna; Maitra, Souvik; Baidya, Dalim K
2018-06-01
Possible advantages and risks associated with ultrasound guided radial artery cannulation in-comparison to digital palpation guided method in adult patients are not fully known. We have compared ultrasound guided radial artery cannulation with digital palpation technique in this meta-analysis. Meta-analysis of randomized controlled trials. Trials conducted in operating room, emergency department, cardiac catheterization laboratory. PubMed and Cochrane Central Register of Controlled Trials (CENTRAL) were searched (from 1946 to 20th November 2017) to identify prospective randomized controlled trials in adult patients. Two-dimensional ultrasound guided radial artery catheterization versus digital palpation guided radial artery cannulation. Overall cannulation success rate, first attempt success rate, time to cannulation and mean number of attempts to successful cannulation. Odds ratio (OR) and standardized mean difference (SMD) or mean difference (MD) with 95% confidence interval (CI) were calculated for categorical and continuous variables respectively. Data of 1895 patients from 10 studies have been included in this meta- analysis. Overall cannulation success rate was similar between ultrasound guided technique and digital palpation [OR (95% CI) 2.01 (1.00, 4.06); p = 0.05]. Ultrasound guided radial artery cannulation is associated with higher first attempt success rate of radial artery cannulation in comparison to digital palpation [OR (95% CI) 2.76 (186, 4.10); p < 0.001]. No difference was seen in time to cannulate [SMD (95% CI) -0.31 (-0.65, 0.04); p = 0.30] and mean number of attempt [MD (95% CI) -0.65 (-1.32, 0.02); p = 0.06] between USG guided technique with palpation technique. Radial artery cannulation by ultrasound guidance may increase the first attempt success rate but not the overall cannulation success when compared to digital palpation technique. However, results of this meta-analysis should be interpreted with caution due presence of heterogeneity. Copyright © 2018 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sarma, Asha, E-mail: ashasarma@gmail.com; Shyn, Paul B., E-mail: pshyn@partners.org; Vivian, Mark A.
Bilateral adrenalectomy is currently the only available treatment for adrenocorticotropic hormone (ACTH)-dependent Cushing’s syndrome (ectopic ACTH syndrome) that is refractory to pharmacologic therapy. We describe two patients with refractory ectopic ACTH syndrome who were treated with CT-guided percutaneous microwave ablation of both hyperplastic adrenal glands in a single session: One was not a surgical candidate, and the other had undergone unsuccessful surgery. Following the procedure, both patients achieved substantial decreases in serum cortisol, symptomatic improvement, and decreased anti-hypertensive medication requirements.
Enhanced Lesion Visualization in Image-Guided Noninvasive Surgery With Ultrasound Phased Arrays
2001-10-25
81, 1995. [4] N. Sanghvi et al., “Noninvasive surgery of prostate tissue by high-intensity focused ultrasound ,” IEEE Trans. UFFC, vol. 43, no. 6, pp...ENHANCED LESION VISUALIZATION IN IMAGE-GUIDED NONINVASIVE SURGERY WITH ULTRASOUND PHASED ARRAYS Hui Yao, Pornchai Phukpattaranont and Emad S. Ebbini...Department of Electrical and Computer Engineering University of Minnesota Minneapolis, MN 55455 Abstract- We describe dual-mode ultrasound phased
Nam, Sang Yu; Rhim, Hyunchul; Kang, Tae Wook; Lee, Min Woo; Kim, Young-Sun; Choi, Dongil; Lee, Won Jae; Park, Yulri; Chang, Ilsoo; Lim, Hyo K
2010-02-01
This study was designed to assess whether artificial ascites has a heat-sink effect on the ablation zone for percutaneous radiofrequency ablation (RFA) of hepatic tumors abutting the diaphragm. We retrospectively assessed 28 patients who underwent percutaneous RFA for the treatment of a single nodular hepatic tumor that abutted the diaphragm from July 2000 to December 2006. All patients underwent ultrasound-guided RFA using internally cooled electrodes. A single ablation for 12 minutes was applied using 3-cm active-tip electrodes. We divided patients into two groups on the basis of whether artificial ascites was introduced before RFA: Group A consisted of patients who received artificial ascites with a mean of 760 mL of a 5% dextrose in water solution (n = 15) and group B consisted of patients who did not receive artificial ascites (n = 13). The volume of the ablation zone was measured on CT images obtained immediately after the ablation procedure, and imaging findings were compared for both groups using the Student's t test. We also compared the local tumor progression rate between both groups using the chi-square test (mean follow-up, 37.4 months). There was no significant difference between the two patient groups with regard to age, sex, Child-Pugh class, or tumor location (p > 0.05). The tumors were significantly smaller in group A patients (mean +/- SD, 1.6 +/- 0.5 cm) than in group B patients (2.1 +/- 0.7 cm) (p = 0.019). The mean volume of the RFA zone was 31.6 +/- 11.9 cm(3) in group A patients and 30.9 +/- 11.0 cm(3) in group B patients. There was no significant difference between the groups in the ablation volume (p = 0.871). Local tumor progression was noted in four patients (26.7%) in group A and in three patients (23.1%) in group B. There was no significant difference in the local tumor progression rate between the two groups (p = 0.83). Artificial ascites did not show a heat-sink effect on the volume of the ablation zone after percutaneous RFA for the treatment of a hepatic tumor abutting the diaphragm.
Complications and adequacy of transplant kidney biopsies: A comparison of techniques.
Plattner, Brett W; Chen, Pauline; Cross, Richard; Leavitt, Matthew A; Killen, Paul D; Heung, Michael
2018-05-01
Kidney biopsies are an essential tool in the diagnosis and management of kidney diseases, particularly in kidney transplant recipients. Biopsies carry a risk for serious complications and not all biopsies achieve adequate tissue. We examined the impact of kidney biopsy technique on complications and biopsy adequacy. The cohort consisted of consecutive kidney transplant patients undergoing biopsy by one of three techniques: ultrasound localization, real-time ultrasound guidance, and ultrasound-guided trocar placement. Variables of interest included patient characteristics and procedural characteristics. The primary outcome was serious complication attributable to kidney biopsy, and the secondary outcome was biopsy adequacy as defined by Banff criteria. Among 263 patients undergoing biopsy, 27 (10.3%) had a complication (14 with gross hematuria, 10 requiring blood transfusion, 3 requiring an unplanned interventional radiology procedure, 1 kidney loss; no deaths). Complications were more common among patients biopsied using ultrasound-guided trocar compared to real-time ultrasound and ultrasound localization (21.4% vs 7.9% vs 7.1%, respectively, p = 0.008). After adjusting for patient and procedure characteristics, technique was no longer significantly associated with complication. Biopsy adequacy was significantly higher when using ultrasound localization and real-time ultrasound compared to ultrasound-guided trocar (84.6% vs 86.8% vs 69.6%, p = 0.029), and this finding persisted in adjusted analysis. Kidney biopsy complications appear to be similar when using any of the three techniques examined in our study. However, ultrasound-guided trocar technique may yield lower biopsy adequacy when compared to non-trocar techniques.
Towards enabling ultrasound guidance in cervical cancer high-dose-rate brachytherapy
NASA Astrophysics Data System (ADS)
Wong, Adrian; Sojoudia, Samira; Gaudet, Marc; Yap, Wan Wan; Chang, Silvia D.; Abolmaesumi, Purang; Aquino-Parsons, Christina; Moradi, Mehdi
2014-03-01
MRI and Computed Tomography (CT) are used in image-based solutions for guiding High Dose Rate (HDR) brachytherapy treatment of cervical cancer. MRI is costly and CT exposes the patients to ionizing radiation. Ultrasound, on the other hand, is affordable and safe. The long-term goal of our work is to enable the use of multiparametric ultrasound imaging in image-guided HDR for cervical cancer. In this paper, we report the development of enabling technology for ultrasound guidance and tissue typing. We report a system to obtain the 3D freehand transabdominal ultrasound RF signals and B-mode images of the uterus, and a method for registration of ultrasound to MRI. MRI and 3D ultrasound images of the female pelvis were registered by contouring the uterus in the two modalities, creating a surface model, followed by rigid and B-spline deformable registration. The resulting transformation was used to map the location of the tumor from the T2-weighted MRI to ultrasound images and to determine cancerous and normal areas in ultrasound. B-mode images show a contrast for cancer vs. normal tissue. Our study shows the potential and the challenges of ultrasound imaging in guiding cervical cancer treatments.
Qian, Xiaohua; Hecht, Jonathan L
2003-01-01
To compare the sensitivity and specificity of pancreatic fine needle aspiration (FNA) with computed tomography (CT) and endoscopic ultrasound (EUS) guidance. A 6-year retrospective review included 137 pancreatic FNAs (CT 51, magnetic resonance imaging 2 or EUS 84). Clinical or histologic follow-up was available for 110 patients. Positive (POS), suspicious (SUS), atypical, negative and unsatisfactory (UNSAT) results represented 25.5%, 7.3%, 7.3%, 40.1% and 19.1% of reported diagnoses, respectively. In detecting malignancy, the sensitivities of POS/SUS results were 71% and 42% for CT and EUS, respectively, with negative predictive value (NPV) of 41% and 45%. Also, 35% of UNSAT results were found to have malignancy. However, EUS was used on more difficult lesions, including 82% of small, cystic ones and 75% of small, solid ones. Although the apparent performance of percutaneous CT-guided biopsies surpasses that of EUS, this is due to the choice of endoscopy for more difficult lesions. The specificity and negative predictive value of EUS and CT are similar.
Radiology of colorectal cancer.
Pijl, M E J; Chaoui, A S; Wahl, R L; van Oostayen, J A
2002-05-01
In the past 20 years, the radiology of colorectal cancer has evolved from the barium enema to advanced imaging modalities like phased array magnetic resonance imaging (MRI), virtual colonoscopy and positron emission tomography (PET). Nowadays, primary rectal cancers are preferably imaged with transrectal ultrasound or MRI, while barium enema is still the most often used technique for imaging of colonic cancers. Virtual colonoscopy is rapidly evolving and might considerably change the imaging of colorectal cancer in the near future. The use of virtual colonoscopy for screening purposes and imaging of the colon in occlusive cancer or incomplete colonoscopies is currently under evaluation. The main role of PET is in detecting tumour recurrences, both locally and distantly. Techniques to fuse cross-sectional anatomical (computer tomography (CT) and MRI) and functional (PET) images are being developed. Apart from diagnostic imaging, the radiologists has added image-guided minimally invasive treatments of colorectal liver metastases to their arsenal. The radio-frequency ablation technique is now widely available, and can be used during laparotomy or percutaneously in selected cases.
Lee, Jae Min; Lee, Sang Hyub; Jang, Dong Kee; Chung, Kwang Hyun; Park, Jin Myung; Paik, Woo Hyun; Lee, Jun Kyu; Ryu, Ji Kon; Kim, Yong-Tae
2016-03-01
Although endoscopic bilateral stent-in-stent (SIS) placement of self-expandable metallic stents (SEMS) is one of the major palliative treatments for unresectable malignant hilar biliary obstruction, post-endoscopic retrograde cholangiopancreatography (ERCP) cholangitis can occur frequently due to inadequate drainage, especially after contrast injection into the biliary tree. The aim of this study is to evaluate the efficacy and safety of air cholangiography-assisted stenting. This study included 47 patients with malignant hilar biliary obstruction who underwent endoscopic bilateral SEMS placement using the SIS technique. They were divided into two groups, air (n = 23) or iodine contrast (n = 24) cholangiography. We retrospectively compared comprehensive clinical and laboratory data of both groups. There were no significant differences found between the two groups with respect to technical success (87% versus 87.5%, air versus contrast group, respectively), functional success (95% versus 95.2%), 30-day mortality (8.3% versus 8.7%) and stent patency. Post-ERCP adverse events occurred in 5 (21.7%) of the patients in the air group and 8 (33.3%) of the patients in the contrast group. Among these, the rate of cholangitis was significantly lower in the air group (4.8% versus 29.2%, p = 0.048). In multivariate analysis, air cholangiography, technical success and a shorter procedure time were significantly associated with a lower incidence of post-ERCP cholangitis. Air cholangiography-assisted stenting can be a safe and effective method for endoscopic bilateral SIS placement of SEMS in patients with malignant hilar biliary obstruction.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thompson, Scott M., E-mail: Thompson.scott@mayo.edu; Callstrom, Matthew R., E-mail: callstrom.matthew@mayo.edu; McKusick, Michael A., E-mail: mckusick.michael@mayo.edu
PurposeThe purpose of this study was to determine the feasibility, safety, and early effectiveness of percutaneous image-guided ablation as second-line treatment for symptomatic soft-tissue vascular anomalies (VA).Materials and MethodsAn IRB-approved retrospective review was undertaken of all patients who underwent percutaneous image-guided ablation as second-line therapy for treatment of symptomatic soft-tissue VA during the period from 1/1/2008 to 5/20/2014. US/CT- or MRI-guided and monitored cryoablation or MRI-guided and monitored laser ablation was performed. Clinical follow-up began at one-month post-ablation.ResultsEight patients with nine torso or lower extremity VA were treated with US/CT (N = 4) or MRI-guided (N = 2) cryoablation or MRI-guided laser ablation (N = 5)more » for moderate to severe pain (N = 7) or diffuse bleeding secondary to hemangioma–thrombocytopenia syndrome (N = 1). The median maximal diameter was 9.0 cm (6.5–11.1 cm) and 2.5 cm (2.3–5.3 cm) for VA undergoing cryoablation and laser ablation, respectively. Seven VA were ablated in one session, one VA initially treated with MRI-guided cryoablation for severe pain was re-treated with MRI-guided laser ablation due to persistent moderate pain, and one VA was treated in a planned two-stage session due to large VA size. At an average follow-up of 19.8 months (range 2–62 months), 7 of 7 patients with painful VA reported symptomatic pain relief. There was no recurrence of bleeding at five-year post-ablation in the patient with hemangioma–thrombocytopenia syndrome. There were two minor complications and no major complications.ConclusionImage-guided percutaneous ablation is a feasible, safe, and effective second-line treatment option for symptomatic VA.« less
Wu, Xiaoyun; Xu, Yun
2015-05-01
The aim of this study was to determine clinical performance of gestrinone combined with ultrasound-guided aspiration and ethanol injection in treating chocolate cyst of ovary. Sixty-eight patients enrolled in this study were randomly divided into two groups: control group and combination treatment group. In the control group, 34 patients were treated with ultrasound-guided aspiration and ethanol injection. In the combination treatment group, 34 patients received gestrinone p.o. following ultrasound-guided aspiration and ethanol injection. The recurrence rate of chocolate cyst was 10-fold lower in the combination treatment group (2.94%, 1/34) than in the control group (29.4%, 10/34) at 12 months. The effective rate for reduction of chocolate cyst was significantly higher in the combination treatment group (94.12%, 32/34) than in the control group (64.71%, 22/34) (P = 0.009). Gestrinone combined with ultrasound-guided aspiration and ethanol injection therapy is an effective treatment for ovarian chocolate cyst with low recurrence rate. © 2014 The Authors. Journal of Obstetrics and Gynaecology Research © 2014 Japan Society of Obstetrics and Gynecology.
Actual Time Required for Dynamic Fluoroscopic Intraoperative Cholangiography
Whitwam, Paul; Turner, David; Kennedy, Kathy; Hashmi, Syed
2005-01-01
Objectives: This study was undertaken to determine the actual amount of time a dynamic fluoroscopic intraoperative cholangiogram adds to a laparoscopic cholecystectomy. A secondary objective was to define the information gained from this procedure. Methods: A consecutive case study of 52 patients undergoing laparoscopic cholecystectomy was used. Time was recorded from placement of a laparoscopic hemoclip across the cystic duct at its junction with the gallbladder until successful completion of the intraoperative cholangiogram. The mean, median, and range of times for these cases, as well as the results and false-negative rates, were determined. Results: Cholangiography was successfully completed in 96% of patients. The mean time added to laparoscopic cholecystectomy by the addition of dynamic fluoroscopic intraoperative cholangiography was 4.3 minutes. The median time was 3.0 minutes. The times ranged from 2.0 minutes to 16.0 minutes. Choledocholithiasis was present in 15.4% of these patients. The false-positive rate was zero in this study. Conclusions: Dynamic fluoroscopic intraoperative cholangiogram was fast and efficient. The information gained was significant in that 15% of patients proceeded on to laparoscopic common bile duct exploration. We conclude that intraoperative cholangiography should be a routine addition to laparoscopic cholecystectomy. PMID:15984705
Rawat, B; Loewy, J
1996-08-01
To evaluate the role of magnetic resonance cholangiography (MRC) in patients with suspected choledocholithiasis. Twenty-six consecutive patients with suspected choledocholithiasis (11 men and 15 women ranging in age from 25 to 81 years) underwent three-dimensional gradient-echo MRC; each patient also underwent endoscopic retrograde cholangiography or operative cholangiography. Each set of images for each patient was reviewed independently by a radiologist who was unaware of the results of the other type of imaging. Diagnostic-quality MRC images were obtained for 17 of the patients. Of these, 13 had stones in the common bile duct, as confirmed by another imaging method, and MRC indicated the presence of these stones in all 13 patients. In the other four patients bile duct obstruction was due to either acute pancreatitis (in three) or cholangiocarcinoma (in one). For seven of the nine nondiagnostic-quality MRC studies, the bile duct was not obstructed, so there was no bile stasis and the MRC images could not be obtained. Motion artifacts due to inability to hold the breath were the limiting factors in the other two patients. Although MRC has some limitations, this new noninvasive technique may be used as a screening test in selected patients with suspected choledocholithiasis.
Guiding intramuscular diaphragm injections using real-time ultrasound and electromyography.
Sarwal, Aarti; Cartwright, Michael S; Mitchell, Erin; Williams, Koudy; Walker, Francis O; Childers, Martin K
2015-02-01
We describe a unique method that combines ultrasound and electromyography to guide intramuscular diaphragm injections in anesthetized large animals. Ultrasound was used to visualize the diaphragm on each side of spontaneously breathing, anesthetized beagle dogs and cynomolgus macaques. An electromyography (EMG) needle was introduced and directed by ultrasound to confirm that the needle entered the muscular portion of the diaphragm, and methylene blue was injected. Injection accuracy was confirmed upon necropsy by tracking the spread of methylene blue. All methylene blue injections were confirmed to have been placed appropriately into the diaphragm. This study demonstrates the feasibility and accuracy of using ultrasound and EMG to guide injections and to reduce complications associated with conventional blind techniques. Ultrasound guidance can be used for clinical EMG of the diaphragm. Future applications may include targeted diaphragm injections with gene replacement therapy in neuromuscular diseases. © 2014 Wiley Periodicals, Inc.
Guiding Intramuscular Diaphragm Injections Using Real-time Ultrasound & Electromyography
Sarwal, Aarti; Cartwright, Michael S.; Mitchell, Erin; Williams, Koudy; Walker, Francis O.; Childers, Martin K.
2014-01-01
Introduction We describe a unique method that combines ultrasound and electromyography to guide intramuscular diaphragm injections in anesthetized large animals. Methods Ultrasound was used to visualize the diaphragm on each side of spontaneously breathing, anesthetized beagle dogs and cynomolgus macaques. An electromyography needle was introduced and directed by ultrasound to confirm that the needle entered the muscular portion of the diaphragm, and methylene blue was injected. Injection accuracy was confirmed upon necropsy by tracking the spread of methylene blue. Results All methylene blue injections were confirmed to have been placed appropriately into the diaphragm. Conclusions This study demonstrates the feasibility and accuracy of using ultrasound and EMG to guide injections and to reduce complications associated with conventional blind techniques. Ultrasound guidance can be used for clinical electromyography of the diaphragm. Future applications may include targeted diaphragm injections with gene replacement therapy in neuromuscular diseases. PMID:25354257
Remotely Guided Breast Sonography for Long-Term Space Missions: A Case Report and Discussion.
Silva-Martinez, Jackelynne P; Sorice Genaro, Andreia; Wen, Hui Annie; Glauber, Naama; Russomano, Thais
2017-12-01
Space radiation can cause different types of cancers in crewmembers, especially during long-term space missions. To date, a complete bilateral breast ultrasound has not been performed at the International Space Station (ISS). A breast screening imaging technique could be a useful tool for early identification of breast cancer in astronauts. We hypothesized that breast ultrasound performed by a crewmember while being remotely guided by a specialist from the ground could be an essential tool for medical diagnosis in space. This project aimed to test an ultrasound screening protocol for breast tissue using real-time remotely guided telemedicine techniques. One female volunteer, with no previous medical experience, performed a self-scanned bilateral breast ultrasound exam guided by a remote sonographer. Dynamic ultrasound images were collected using a 25 mm broadband linear array transducer. To simulate fluid shift on the volunteer during microgravity, the bed was tilted -6°. Recorded ultrasound images were analyzed by radiologists, comparing the findings with a gold standard. The experiment demonstrated that real-time remotely guided sonography exam is feasible and can yield meaningful clinical results. This case study showed that remotely guided breast ultrasound can be performed and might become an important tool for diagnosis of breast cancer in space missions. The results cannot be generalized based on one subject, and additional research is warranted in this area in addition to its validation on the ISS. This technique, however, has potential for use as part of preventive medicine procedures for long-term space missions at the ISS, and eventually for human settlements on the Moon and Mars.
Baghbani, Fatemeh; Chegeni, Mahdieh; Moztarzadeh, Fathollah; Hadian-Ghazvini, Samaneh; Raz, Majid
2017-05-01
Ultrasound-responsive nanodroplets are a class of new emerging smart drug delivery systems which provide image-guided nano-therapy of various diseases, especially cancers. Here, we developed multifunctional smart curcumin-loaded chitosan/perfluorohexane nanodroplets for contrast-ultrasound imaging and on-demand drug delivery. The nanodroplets were synthesized via nanoemulsion process. The optimal formulation with the size of 101.2nm and 77.8% curcumin entrapment was chosen for release study and cytotoxicity evaluation. Sonication at the frequency of 1MHz, 2W/cm 2 for 4min triggered the release of 63.5% of curcumin from optimal formulation (Cur-NDs-2). Ultrasound aided release study indicated that the concentration of perfluorohexane and the degree of acoustic droplet vaporization play important role in ultrasound-active drug release. B-mode ultrasound imaging confirmed strong ultrasound contrast of chitosan nanodroplets even at low concentrations via droplet to bubble transition. Finally, cytotoxicity of the ultrasound-responsive nanodroplets in the presence of ultrasound was evaluated in-vitro on 4T1 human breast cancer cells. Cell growth inhibitory effects of curcumin-loaded nanodroplets significantly increased by ultrasound exposure. According to the obtained results, these ultrasound responsive curcumin-loaded chitosan/perfluorohexane nanodroplets have a great potential for imaged-guided cancer therapy. Copyright © 2016 Elsevier B.V. All rights reserved.
Venderink, Wulphert; Govers, Tim M; de Rooij, Maarten; Fütterer, Jurgen J; Sedelaar, J P Michiel
2017-05-01
Three commonly used prostate biopsy approaches are systematic transrectal ultrasound guided, direct in-bore MRI guided, and image fusion guided. The aim of this study was to calculate which strategy is most cost-effective. A decision tree and Markov model were developed to compare cost-effectiveness. Literature review and expert opinion were used as input. A strategy was deemed cost-effective if the costs of gaining one quality-adjusted life year (incremental cost-effectiveness ratio) did not exceed the willingness-to-pay threshold of €80,000 (≈$85,000 in January 2017). A base case analysis was performed to compare systematic transrectal ultrasound- and image fusion-guided biopsies. Because of a lack of appropriate literature regarding the accuracy of direct in-bore MRI-guided biopsy, a threshold analysis was performed. The incremental cost-effectiveness ratio for fusion-guided biopsy compared with systematic transrectal ultrasound-guided biopsy was €1386 ($1470) per quality-adjusted life year gained, which was below the willingness-to-pay threshold and thus assumed cost-effective. If MRI findings are normal in a patient with clinically significant prostate cancer, the sensitivity of direct in-bore MRI-guided biopsy has to be at least 88.8%. If that is the case, the incremental cost-effectiveness ratio is €80,000 per quality-adjusted life year gained and thus cost-effective. Fusion-guided biopsy seems to be cost-effective compared with systematic transrectal ultrasound-guided biopsy. Future research is needed to determine whether direct in-bore MRI-guided biopsy is the best pathway; in this study a threshold was calculated at which it would be cost-effective.
Lee, Kenneth S; Rosas, Humberto G
2010-09-01
The purpose of this video article is to illustrate the ultrasound appearance of calcium deposition in the rotator cuff and provide a detailed step-by-step protocol for performing the ultrasound-guided single-needle lavage technique for the treatment of calcific tendinitis with emphasis on patient positioning, necessary supplies, real-time lavage technique, and steroid injection into the subacromial subdeltoid bursa. Musculoskeletal ultrasound is well established as a safe, cost-effective imaging tool in diagnosing and treating common musculoskeletal disorders. Calcific tendinitis of the rotator cuff is a common disabling cause of shoulder pain. Although most cases are self-limiting, a subset of patients is refractory to conservative therapy and requires treatment intervention. Ultrasound-guided lavage is an effective and safe minimally-invasive treatment not readily offered in the United States as an alternative to surgery, perhaps because of the limited prevalence of musculoskeletal ultrasound programs and limited training. On completion of this video article, the participant should be able to develop an appropriate diagnostic and therapeutic algorithm for the treatment of calcific tendinitis of the rotator cuff using ultrasound.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Choi, Jae Woong, E-mail: cooljay@korea.ac.kr; Lu, David S. K., E-mail: dlu@mednet.ucla.edu; Osuagwu, Ferdnand, E-mail: fosuagwu@mednet.ucla.edu
2013-11-07
PurposeTo evaluate the chronological effects of irreversible electroporation (IRE) on large hilar bile ducts in an in vivo porcine model correlated with computed tomography (CT) cholangiography and histopathology.Materials and MethodsTwelve IRE zones were made along hilar bile ducts intraoperatively under ultrasound (US)-guidance in 11 pigs. Paired electrodes were placed either on opposing sides of the bile duct (straddle [STR]) or both on one side of the bile duct (one-sided [OSD]). The shortest electrode-to-duct distance was classified as periductal (≤2 mm) or nonperiductal (>2 mm). CT cholangiography and laboratory tests were performed before IRE and again at 2 days, 4 weeks, and 8 weeks after IRE.more » Degree of bile duct injury were graded as follows: grade 0 = no narrowing; grade 1 = ≤50 % duct narrowing; grade 2 = >50 % narrowing without proximal duct dilatation; grade 3 = grade 2 with proximal duct dilatation; and grade 4 = grade 3 with enzyme elevation. Pigs were selected for killing and histopathology at 2 days, 4, and 8 weeks.ResultsNonperiductal electrode placement produced no long-term strictures in 5 of 5 ducts. Periductal electrode placement produced mild narrowing in 6 of 7 ducts: 5 grade 1 and 1 grade 2. None showed increased enzymes. There was no significant difference between STR versus OSD electrode placement. Histopathology showed minor but relatively greater ductal mural changes in narrowed ducts.ConclusionIn the larger hilar ducts, long-term patency and mural integrity appear resistant to IRE damage with the energy deposition used, especially if the electrode is not immediately periductal in position.« less
Transcranial MR-Guided Focused Ultrasound: A Review of the Technology and Neuro Applications
Ghanouni, Pejman; Pauly, Kim Butts; Elias, W. Jeff; Henderson, Jaimie; Sheehan, Jason; Monteith, Stephen; Wintermark, Max
2015-01-01
MR guided focused ultrasound is a new, minimally invasive method of targeted tissue thermal ablation that may be of use to treat central neuropathic pain, essential tremor, Parkinson tremor, and brain tumors. The system has also been used to temporarily disrupt the blood-brain barrier to allow targeted drug delivery to brain tumors. This article reviews the physical principles of MR guided focused ultrasound and discusses current and potential applications of this exciting technology. PMID:26102394
Suzuki, Yoriyasu; Tsuchikane, Etsuo; Katoh, Osamu; Muramatsu, Toshiya; Muto, Makoto; Kishi, Koichi; Hamazaki, Yuji; Oikawa, Yuji; Kawasaki, Tomohiro; Okamura, Atsunori
2017-11-13
This report describes the registry and presents an initial analysis of outcomes for the different PCI approaches taken by the specialists. Strategies for percutaneous coronary intervention (PCI) for chronic total occlusion (CTO) are complex. The Japanese Board of CTO Interventional Specialists has developed a prospective, nonrandomized registry of patients undergoing CTO-PCIs performed by 41 highly experienced Japanese specialists. Over the study period of January 2014 to December 2015, the registry included 2,846 consecutive CTO-PCI cases undertaken in Japan. The authors compared clinical outcomes between the different PCI approaches, following the intention-to-treat principle. The overall technical success rate of the procedures was 89.9%. The specialists frequently chose a retrograde approach as the primary CTO-PCI strategy (in 27.8% of cases). The technical success rate of the primary antegrade approach was significantly better than that of the primary retrograde approach (91.0% vs. 87.3%; p < 0.0001). The technical success rate decreased to 78.0% with the rescue retrograde approach. Parallel guidewire crossing and intravascular ultrasound-guided wire crossing were performed after guidewire escalation during antegrade CTO-PCI with a high technical success rate (75.0% to 88.9%). Severe lesion calcification was a strong predictor of failed CTO-PCI. CTO-PCI performed by highly experienced specialists achieved a high technical success rate. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Reduced-dose C-arm computed tomography applications at a pediatric institution.
Acord, Michael; Shellikeri, Sphoorti; Vatsky, Seth; Srinivasan, Abhay; Krishnamurthy, Ganesh; Keller, Marc S; Cahill, Anne Marie
2017-12-01
Reduced-dose C-arm computed tomography (CT) uses flat-panel detectors to acquire real-time 3-D images in the interventional radiology suite to assist with anatomical localization and procedure planning. To describe dose-reduction techniques for C-arm CT at a pediatric institution and to provide guidance for implementation. We conducted a 5-year retrospective study on procedures using an institution-specific reduced-dose protocol: 5 or 8 s Dyna Rotation, 248/396 projection images/acquisition and 0.1-0.17 μGy/projection dose at the detector with 0.3/0.6/0.9-mm copper (Cu) filtration. We categorized cases by procedure type and average patient age and calculated C-arm CT and total dose area product (DAP). Two hundred twenty-two C-arm CT-guided procedures were performed with a dose-reduction protocol. The most common procedures were temporomandibular and sacroiliac joint injections (48.6%) and sclerotherapy (34.2%). C-arm CT was utilized in cases of difficult percutaneous access in less common applications such as cecostomy and gastrostomy placement, foreign body retrieval and thoracentesis. C-arm CT accounted for between 9.9% and 80.7% of the total procedural DAP. Dose-reducing techniques can preserve image quality for intervention while reducing radiation exposure to the child. This technology has multiple applications within pediatric interventional radiology and can be considered as an adjunctive imaging tool in a variety of procedures, particularly when percutaneous access is challenging despite routine fluoroscopic or ultrasound guidance.
DOE Office of Scientific and Technical Information (OSTI.GOV)
McGraw, J. Kevin; Strnad, Bradley T.; Patzik, Shayle B.
Percutaneous vertebroplasty with polymethylmethacrylate (PMMA) is an effective procedure for relieving pain due to vertebral body compression fractures. The technique employs iodinated contrast venography to exclude needle placement directly within the basivertebral complex. We present two cases in which carbon dioxide (CO{sub 2}) and gadopentetate dimeglumine venography was used to guide percutaneous vertebroplasty in patients with a contraindication to iodinated contrast.
Pan, Xiang-Bin; Ouyang, Wen-Bin; Wang, Shou-Zheng; Liu, Yao; Zhang, Da-Wei; Zhang, Feng-Wen; Pang, Kun-Jing; Zhang, Zhe; Hu, Sheng-Shou
2016-07-01
Percutaneous patent ductus arteriosus (PDA) occlusion has become the preferred therapeutic option, which uses fluoroscopy as the guidance. To reduce the x-ray exposure, PDA occlusion using the Amplatzer Duct Occluder II (ADO II) under guidance of transthoracic echocardiography only was conducted. This single center study aims to access the safety and efficiency of this new strategy. From June 2013 to May 2015, 63 consecutive PDA patients underwent transthoracic echocardiography-guided PDA occlusion through the femoral artery. Outpatient follow-up was conducted at 1, 3, and 6 months, and yearly. Sixty-two patients successfully underwent echocardiography-guided percutaneous PDA occlusion. One patient was converted to minimally invasive transthoracic occlusion due to failure of delivery sheath passage through tortuous PDA. Mean procedure duration was 24.3 ± 7.0 minutes; ADO II diameter averaged 4.6 ± 0.9 mm; 8 cases showed traces of residual shunt immediately after operation which resolved after 24 hours; and mean hospital stay was 3.4 ± 0.5 days. There was no occluder migration, hemolysis, pericardial effusion, pulmonary branch or aortic stenosis at mean 13.5 ± 4.8 months follow-up. This study demonstrated that percutaneous PDA occlusion can be successfully performed under guidance of transthoracic echocardiography only and appears safe and effective while avoiding radiation and contrast agent use. © 2016, Wiley Periodicals, Inc.
Opolski, Maksymilian P; Debski, Artur; Borucki, Bartosz A; Szpak, Marcin; Staruch, Adam D; Kepka, Cezary; Witkowski, Adam
2016-06-01
We report a case of successful computed tomography-guided percutaneous revascularization of a chronically occluded right coronary artery using a wearable, hands-free computer with a head-mounted display worn by interventional cardiologists in the catheterization laboratory. The projection of 3-dimensional computed tomographic reconstructions onto the screen of virtual reality glass allowed the operators to clearly visualize the distal coronary vessel, and verify the direction of the guide wire advancement relative to the course of the occluded vessel segment. This case provides proof of concept that wearable computers can improve operator comfort and procedure efficiency in interventional cardiology. Copyright © 2016 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.
Watson, Timothy; El-Jack, Seifeddin; Stewart, James T; Ormiston, John
2013-09-01
Intravascular ultrasound (IVUS) is a proven and safe imaging modality used to guide percutaneous coronary intervention (PCI). The Volcano VIBE™ RX Vascular Imaging Balloon Catheter is a novel rapid exchange, 0.014" wire-compatible multi-lumen conventional balloon catheter modified with the addition of an IVUS transducer proximal to the balloon, delivered via a standard 6 Fr sheath. We sought to evaluate the safety, balloon performance, and image quality of the VIBE™ RX in patients scheduled for coronary intervention. Patients aged >21 and <85 years with single or multivessel coronary disease scheduled for PCI due to coronary ischaemic symptoms were included. Those with angiographic features that precluded the safe or informative use of the device were excluded. Twenty-nine patients having angiography because of ischaemic symptoms underwent 44 VIBE RX imaging runs, with balloon dilation in 20. Successful device deployment was achieved in all but one patient. All images were adequate and reproducible. One patient had a non-ST-elevation MI felt to be due to the complexity of the procedure rather than directly related to the VIBE™ RX. The study demonstrated the safety and effectiveness of the VIBE™ RX for its intended purpose with minimal failure rate and no directly related complications.
Aoki, Yasuhiro; Takamiya, Masataka; Satoh, Takashi; Fujita, Sachiko; Kato, Hideaki; Maeno, Yoshitaka
2011-07-01
An autopsy case of fatal complication of percutaneous liver biopsy targeting a rare type of large B-cell lymphoma is presented. A 79 year-old man was referred to the hematology unit of a hospital because of anemia with thrombocytopenia and hepatosplenomegaly. Results of inguinal lymph node biopsy were inconclusive. To investigate a mass lesion in the liver visualized by ultrasonography, image-guided liver biopsy was performed following platelet infusion. The patient became unresponsive 6h post procedure because of hypotension due to intraperitoneal hemorrhage of undetermined origin. Autopsy revealed hemoperitoneum but failed to identify any macroscopic intra- or extrahepatic vascular injuries. Histopathological investigation disclosed infiltration of atypical lymphocytes into the systemic organs including the lymph nodes, spleen, liver, and lungs. Prominent hemophagocytosis was also noted. The lymphoma cells were exclusively accumulated within vascular and sinusoidal structures, and diagnosed with immunohistochemistry as Asian variant of intravascular large B-cell lymphoma. Massive blood extravasation was presumed to originate directly from the markedly dilated liver sinusoids filled with erythrocytes, macrophages and tumor cells, under the condition of impaired hemostasis. Although the biopsy was thought to have been correctly performed, this case would be instructive for evaluation of the indications and risks associated with liver biopsy. 2011 Elsevier Ireland Ltd. All rights reserved.
A successful model to learn and implement ultrasound-guided venous catheterization in apheresis.
Gopalasingam, Nigopan; Thomsen, Anna-Marie Eller; Folkersen, Lars; Juhl-Olsen, Peter; Sloth, Erik
2017-12-01
Apheresis treatments can be performed with peripheral venous catheters (PVC), although central venous catheters (CVC) are inserted when PVCs fail or patient with history of difficult vascular access prior to the apheresis. Ultrasound guidance for PVC has shown promising results in other settings. To investigate if ultrasound guidance for PVC could be implemented among apheresis nurses. Second, how implementation of ultrasound guidance affected the number of CVCs used for apheresis per patient. Apheresis nurses completed a systematic training program for ultrasound-guided vascular access. All independent catheterizations were registered during the implementation stage. The number of CVCs in the pre- and postimplementation stages of the ultrasound guidance was compared. Six nurses completed the training program within a median of 48 days (range 38-83 days). In 77 patients, 485 independent ultrasound-guided PVC placements were performed during the implementation stage. All apheresis treatments (485/485) were accomplished using PVCs without requiring CVC as rescue. During the preimplementation stage, 125 of 273 (45.8%) procedures required a CVC for completion of apheresis procedures; during the postimplementation stage only 30 of 227 (13.2%) procedures required a CVC (p < 0.001). In the postimplementation stage, no CVCs were placed as rescue caused by failed PVCs but were only placed for patients where the ultrasound machine was unavailable. It indicates an effective success rate of 100% for ultrasound-guided PVC use. This study showed that ultrasound guidance could be implemented among apheresis nurses as a routine tool eliminating the need of CVC as a rescue. © 2017 Wiley Periodicals, Inc.
Quezada-Gaon, Natacha; Wortsman, Ximena; Peñaloza, Osvaldo; Carrasco, Juan Eduardo
2016-09-01
Botulinum toxin type A has been used for treating the hypertrophy of the masseter muscles and its cosmetic effects. Ultrasound is increasingly used in dermatology, along with the guidance of mini-invasive procedures. To evaluate the role of ultrasound for guiding the application of Botulinum A toxin in patients with cosmetic alterations due to bruxism, correlate the clinical landmarks with the ultrasound findings, and study the effect on the symptoms, cosmetics, and quality of life. Twenty individuals with bruxism and cosmetic alterations underwent an ultrasound-guided injection of Botulinum toxin type A in each masseter muscle. Clinical and ultrasound marking of the procedure was compared. Clinical and sonographic evaluation was performed at the time of injection and 3 months later. Ten normal individuals underwent ultrasound of the masseter muscles as a control group. Up to 65% of individuals showed anatomical variants of the salivary glands. The method for clinically marking the skin showed a frequently erroneous location of the anterior point (up to 40% of cases) that was proven by ultrasound to be out of the muscle. In 20% of cases, ultrasound showed that the needle should be longer to enter the muscle. After injection, most of the patients demonstrated a decrease of the symptoms and cosmetic and quality of life improvements. Ultrasound can be a potent tool for guiding the injection of Botulinum toxin into the masseter muscles. It may contribute to a more personalized procedure, better cosmetic results, and help to avoid potential complications. © 2016 Wiley Periodicals, Inc.
Application of Virtual Navigation with Multimodality Image Fusion in Foramen Ovale Cannulation.
Qiu, Xixiong; Liu, Weizong; Zhang, Mingdong; Lin, Hengzhou; Zhou, Shoujun; Lei, Yi; Xia, Jun
2017-11-01
Idiopathic trigeminal neuralgia (ITN) can be effectively treated with radiofrequency thermocoagulation. However, this procedure requires cannulation of the foramen ovale, and conventional cannulation methods are associated with high failure rates. Multimodality imaging can improve the accuracy of cannulation because each imaging method can compensate for the drawbacks of the other. We aim to determine the feasibility and accuracy of percutaneous foramen ovale cannulation under the guidance of virtual navigation with multimodality image fusion in a self-designed anatomical model of human cadaveric heads. Five cadaveric head specimens were investigated in this study. Spiral computed tomography (CT) scanning clearly displayed the foramen ovale in all five specimens (10 foramina), which could not be visualized using two-dimensional ultrasound alone. The ultrasound and spiral CT images were fused, and percutaneous cannulation of the foramen ovale was performed under virtual navigation. After this, spiral CT scanning was immediately repeated to confirm the accuracy of the cannulation. Postprocedural spiral CT confirmed that the ultrasound and CT images had been successfully fused for all 10 foramina, which were accurately and successfully cannulated. The success rates of both image fusion and cannulation were 100%. Virtual navigation with multimodality image fusion can substantially facilitate foramen ovale cannulation and is worthy of clinical application. © 2017 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com
Jeyapalan, Kanagaratnam; Choudhary, Surabhi
2009-11-01
The aim of this study was to describe the technique and usefulness of ultrasound-guided intrasynovial injection of triamcinolone and bupivacaine in treatment of de Quervain's disease. A total of 17 patients with symptomatic De Quervain's disease were included in this study. The procedure involved confirmation of diagnosis with ultrasound followed by guided injection of a mixture of 20 mg of triamcinolone (40 mg/ml) and 1 ml of 0.5% bupivacaine. Ultrasound guidance with a high resolution 15-Mhz footprint probe was used for injection into the first dorsal extensor compartment tendon sheath (E1). The response to ultrasound-guided injection was ascertained at the post procedure outpatient clinic appointment according to the follow-up clinic notes. There were 14 female and 3 male patients aged 29 to 74 years. Mean duration of symptoms was 8.9 months. One patient had an atypical septum in the first extensor compartment and the extensor pollicis brevis alone was involved. The mean post-injection follow-up was at 6.75 weeks. One patient was lost to follow-up. Fifteen out of 16 patients had significant symptomatic relief (93.75%). There were no immediate or delayed complications. Recurrence of symptoms was seen in 3 (20%) patients. Ultrasound-guided injection of triamcinolone and bupivacaine is safe and useful in controlling symptoms of De Quervain's disease. Correct needle placement with ultrasound guidance avoids intratendinous injection as well as local complications like fat atrophy and depigmentation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Long, Ling; Cai, Xiaodong; Guo, Ruomi
Parkinson's disease (PD) is a very common neurological disorder. However, effective therapy is lacking. Although the blood-brain-barrier (BBB) protects the brain, it prevents the delivery of about 90% of drugs and nucleotides into the brain, thereby hindering the development of gene therapy for PD. Magnetic resonance imaging (MRI)-guided focused ultrasound delivery of microbubbles enhances the delivery of gene therapy vectors across the BBB and improves transfection efficiency. In the present study, we delivered nuclear factor E2-related factor 2 (Nrf2, NFE2L2) contained in nanomicrobubbles into the substantia nigra of PD rats by MRI-guided focused ultrasound, and we examined the effect ofmore » Nrf2 over-expression in this animal model of PD. The rat model of PD was established by injecting 6-OHDA in the right substantia nigra stereotactically. Plasmids (pDC315 or pDC315/Nrf2) were loaded onto nanomicrobubbles, and then injected through the tail vein with the assistance of MRI-guided focused ultrasound. MRI-guided focused ultrasound delivery of nanomicrobubbles increased gene transfection efficiency. Furthermore, Nrf2 gene transfection reduced reactive oxygen species levels, thereby protecting neurons in the target region. - Highlights: • MRI-guided focused ultrasound enhances gene transfection into the brain of rats. • Increased Nrf2 expression protects neurons in the rat model of PD. • Nrf2 protects neurons in PD by inhibiting ROS production.« less
Disinfection of a probe used in ultrasound-guided prostate biopsy.
Rutala, William A; Gergen, Maria F; Weber, David J
2007-08-01
Transrectal ultrasound (TRUS)-guided prostate biopsies are among the most common outpatient diagnostic procedures in urology clinics and carry the risk of introducing pathogens that may lead to infection. To investigate the effectiveness of procedures for disinfecting a probe used in ultrasound-guided prostate biopsy. The effectiveness of disinfection was determined by inoculating 10(7) colony forming units (cfu) of Pseudomonas aeruginosa at the following 3 sites on the probe: the interior lumen of the biopsy needle guide, the outside surface of the biopsy needle guide, and the interior lumen of the ultrasound probe where the needle guide passes through the transducer. Each site was investigated separately. After inoculation, the probe was immersed in 2% glutaraldehyde for 20 minutes and then assessed for the level of microbial contamination. The results demonstrated that disinfection (ie, a reduction in bacterial load of greater than 7 log(10) cfu) could be achieved if the needle guide was removed from the probe. However, if the needle guide was left in the probe channel during immersion in 2% glutaraldehyde, disinfection was not achieved (ie, the reduction was approximately 1 log(10) cfu). Recommendations for probe disinfection are provided and include disassembling the device and immersing the probe and the needle guide separately in a high-level disinfectant.
Gong, Xiaohua; Zhou, Qi; Chen, Shuoping; Wang, Fang; Wu, Wenjun; Chen, Xiaojun
2017-08-01
To evaluate the efficacy and safety of percutaneous polidocanol injection (PPI) in treatment of predominantly cystic thyroid nodules. This prospective study included 111 patients with 122 benign predominantly cystic thyroid nodules inducing pressure symptoms or cosmetic problems. The nodules were randomized to a single aspiration with (n = 61) or without (n = 61) subsequent PPI and followed up after 1, 3, 6, and 12 months. Ten patients (12 nodules) declined to follow up after aspiration in group 2. Nodule volumes, symptoms scores, and cosmetic scores were evaluated before and after treatment. The therapeutic success rate and safety of PPI for treatment of predominantly cystic thyroid nodules were also evaluated. In the PPI group, the nodule volumes were reduced from 13.67 ± 9.90 to 2.60 ± 2.66 (p < .001). Therapeutic success rate (nodule volume reduction >50%) was obtained in 57 of 61 (93.44%) nodules in the PPI group, compared to seven of 49 (14.29%) in the aspiration group (p < .001). In the aspiration group, the nodule volume was not significantly reduced. The reduction in symptom scores was significantly higher in the PPI group (from 3.60 ± 1.65 to 1.60 ± 1.19) than in the aspiration group (from 3.62 ± 1.89 to 3.30 ± 1.06) (p < .001, between groups). The reduction in cosmetic scores showed a significant difference between groups (p < .001). In total, 4.92% of patients (3/61) in the PPI group and 85.71% (42/49) in the aspiration group showed recurrence during the follow-up period. There was a significant difference in the recurrence rate between groups (p < .001). No major side-effects occurred. US-guided PPI of benign recurrent predominantly cystic thyroid nodules is effective and safe. PPI is an important alternative to benign recurrent predominantly cystic thyroid nodules.
Panizza, Pedro Sergio Brito; de Albuquerque Cavalcanti, Conrado Furtado; Yamaguchi, Nise Hitomi; Leite, Claudia Costa; Cerri, Giovanni Guido; de Menezes, Marcos Roberto
2016-02-01
A giant cell tumor (GCT) is an intermediate grade, locally aggressive neoplasia. Despite advances in surgical and clinical treatments, cases located on the spine and pelvic bones remain a significant challenge. Failure of clinical treatment with denosumab and patient refusal of surgical procedures (hemipelvectomy) led to the use of cryoablation. We report the use of percutaneous CT-guided cryoablation as an alternative treatment, shown to be a minimally invasive, safe, and effective option for a GCT with extensive involvement of the pelvic bones and allowed structural and functional preservation of the involved bones.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Panizza, Pedro Sergio Brito; Albuquerque Cavalcanti, Conrado Furtado de; Yamaguchi, Nise Hitomi
2016-02-15
A giant cell tumor (GCT) is an intermediate grade, locally aggressive neoplasia. Despite advances in surgical and clinical treatments, cases located on the spine and pelvic bones remain a significant challenge. Failure of clinical treatment with denosumab and patient refusal of surgical procedures (hemipelvectomy) led to the use of cryoablation. We report the use of percutaneous CT-guided cryoablation as an alternative treatment, shown to be a minimally invasive, safe, and effective option for a GCT with extensive involvement of the pelvic bones and allowed structural and functional preservation of the involved bones.
Quentin, Michael; Blondin, Dirk; Arsov, Christian; Schimmöller, Lars; Hiester, Andreas; Godehardt, Erhard; Albers, Peter; Antoch, Gerald; Rabenalt, Robert
2014-11-01
Magnetic resonance imaging guided biopsy is increasingly performed to diagnose prostate cancer. However, there is a lack of well controlled, prospective trials to support this treatment method. We prospectively compared magnetic resonance imaging guided in-bore biopsy with standard systematic transrectal ultrasound guided biopsy in biopsy naïve men with increased prostate specific antigen. We performed a prospective study in 132 biopsy naïve men with increased prostate specific antigen (greater than 4 ng/ml). After 3 Tesla functional multiparametric magnetic resonance imaging patients were referred for magnetic resonance imaging guided in-bore biopsy of prostate lesions (maximum 3) followed by standard systematic transrectal ultrasound guided biopsy (12 cores). We analyzed the detection rates of prostate cancer and significant prostate cancer (greater than 5 mm total cancer length or any Gleason pattern greater than 3). A total of 128 patients with a mean ± SD age of 66.1 ± 8.1 years met all study requirements. Median prostate specific antigen was 6.7 ng/ml (IQR 5.1-9.0). Transrectal ultrasound and magnetic resonance imaging guided biopsies provided the same 53.1% detection rate, including 79.4% and 85.3%, respectively, for significant prostate cancer. Magnetic resonance imaging and transrectal ultrasound guided biopsies missed 7.8% and 9.4% of clinically significant prostate cancers, respectively. Magnetic resonance imaging biopsy required significantly fewer cores and revealed a higher percent of cancer involvement per biopsy core (each p <0.01). Combining the 2 methods provided a 60.9% detection rate with an 82.1% rate for significant prostate cancer. Magnetic resonance imaging guided in-bore and systematic transrectal ultrasound guided biopsies achieved equally high detection rates in biopsy naïve patients with increased prostate specific antigen. Magnetic resonance imaging guided in-bore biopsies required significantly fewer cores and revealed a significantly higher percent of cancer involvement per biopsy core. Copyright © 2014 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
In-Bore MR-Guided Biopsy Systems and Utility of PI-RADS.
Fütterer, Jurgen J; Moche, Michael; Busse, Harald; Yakar, Derya
2016-06-01
A diagnostic dilemma exists in cases wherein a patient with clinical suspicion for prostate cancer has a negative transrectal ultrasound-guided biopsy session. Although transrectal ultrasound-guided biopsy is the standard of care, a paradigm shift is being observed. In biopsy-naive patients and patients with at least 1 negative biopsy session, multiparametric magnetic resonance imaging (MRI) is being utilized for tumor detection and subsequent targeting. Several commercial devices are now available for targeted prostate biopsy ranging from transrectal ultrasound-MR fusion biopsy to in bore MR-guided biopsy. In this review, we will give an update on the current status of in-bore MRI-guided biopsy systems and discuss value of prostate imaging-reporting and data system (PIRADS).
Kobayashi, Nobuaki; Mintz, Gary S; Witzenbichler, Bernhard; Metzger, D Christopher; Rinaldi, Michael J; Duffy, Peter L; Weisz, Giora; Stuckey, Thomas D; Brodie, Bruce R; Parvataneni, Rupa; Kirtane, Ajay J; Stone, Gregg W; Maehara, Akiko
2016-07-01
Intravascular ultrasound detects stent edge dissections after percutaneous coronary intervention that are not seen angiographically. This study investigated the association between stent edge dissections and clinical outcomes. ADAPT-DES (Assessment of Dual Antiplatelet Therapy With Drug-Eluting Stents) was a large-scale, prospective, multicenter study of patients undergoing drug-eluting stent implantation. In this prospective substudy, 2062 patients (2433 lesions) were evaluated with intravascular ultrasound to characterize the morphological features and clinical outcomes of stent edge dissection after percutaneous coronary intervention. The prevalence of post-percutaneous coronary intervention stent edge dissection was 6.6% per lesion (161 of 2433). Calcified plaque at the proximal stent edge (relative risk [RR]=1.72; P=0.04) and proximal stent edge expansion (RR=1.18; P=0.004) were predictors for proximal dissection; attenuated plaque at the distal stent edge (RR=3.52; P=0.004), distal reference plaque burden (RR=1.56; P<0.0001), and distal edge stent expansion (RR=1.11; P=0.02) were predictors for distal dissection. At 1-year follow-up, target lesion revascularization was more common in lesions with versus without dissection (5.2% versus 2.7%; P=0.04). Multivariable analysis indicated that residual dissection was associated with target lesion revascularization at 1-year follow-up (RR=2.67; P=0.02). Among lesions with dissection, smaller effective lumen area increased the risk of target lesion revascularization at 1-year follow-up (cutoff value of 5.1 mm(2); P=0.05). Greater stent expansion and the presence of large, calcified, and/or attenuated plaques were independent predictors of stent edge dissection. Residual stent edge dissection, especially with a smaller effective lumen area, was associated with target lesion revascularization during 1-year follow-up after drug-eluting stent implantation. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00638794. © 2016 American Heart Association, Inc.
2009-09-01
first statement of work is to determine if high intensity focused ultrasound ( HIFU ) increases the cellular uptake of AS-MDM2, AS-bcl-2 and AS-PKA...Drug Delivery in Prostate Tumor in vivo Using MR Guided Focused Ultrasound (MRg HIFU ). WC, IFMBE Proceedings 25: pp341-344, 2009 6...pharmaceutical agents in the treatment target. In the model system proposed, pulsed high intensity focused ultrasound ( HIFU ) is hypothesized to improve
The role of ultrasound guidance in pediatric caudal block
Erbüyün, Koray; Açıkgöz, Barış; Ok, Gülay; Yılmaz, Ömer; Temeltaş, Gökhan; Tekin, İdil; Tok, Demet
2016-01-01
Objectives: To compare the time interval of the procedure, possible complications, post-operative pain levels, additional analgesics, and nurse satisfaction in ultrasonography-guided and standard caudal block applications. Methods: This retrospective study was conducted in Celal Bayar University Hospital, Manisa, Turkey, between January and December 2014, included 78 pediatric patients. Caudal block was applied to 2 different groups; one with ultrasound guide, and the other using the standard method. Results: The time interval of the procedure was significantly shorter in the standard application group compared with ultrasound-guided group (p=0.020). Wong-Baker FACES Pain Rating Scale values obtained at the 90th minute was statistically lower in the standard application group compared with ultrasound-guided group (p=0.035). No statistically significant difference was found on the other parameters between the 2 groups. The shorter time interval of the procedure at standard application group should not be considered as a distinctive mark by the pediatric anesthesiologists, because this time difference was as short as seconds. Conclusion: Ultrasound guidance for caudal block applications would neither increase nor decrease the success of the treatment. However, ultrasound guidance should be needed in cases where the detection of sacral anatomy is difficult, especially by palpations. PMID:26837396
Kutty, Shelby; Xie, Feng; Gao, Shunji; Drvol, Lucas K; Lof, John; Fletcher, Scott E; Radio, Stanley J; Danford, David A; Hammel, James M; Porter, Thomas R
2010-01-01
Central venous and arterial catheters are a major source of thrombo-embolic disease in children. We hypothesized that guided high mechanical index (MI) impulses from diagnostic three-dimensional (3D) ultrasound during an intravenous microbubble infusion could dissolve these thrombi. An in vitro system simulating intra-catheter thrombi was created and then treated with guided high MI impulses from 3D ultrasound, utilizing low MI microbubble sensitive imaging pulse sequence schemes to detect the microbubbles (Perflutren Lipid Microsphere, Definity®, Lantheus). Ten aged thrombi over 24 hours old were tested using 3D ultrasound coupled with a continuous diluted microbubble infusion (Group A), and ten with 3D ultrasound alone (Group B). Mean thrombus age was 28.6 hours (range 26.6–30.3). Groups A exhibited a 55 ± 19 % reduction in venous thrombus size, compared to 31±10 % for Group B (p=0.008). Feasibility testing was performed in 4 pigs, establishing a model to further investigate the efficacy. Sonothrombolysis of aged intra-catheter venous thrombi can be achieved with commercially available microbubbles and guided high MI ultrasound from a diagnostic 3D transducer. PMID:20696549
Young, Cody M; Horst, Deanna M; Murakami, James W; Shiels, William E
2015-07-01
The subtalar joint is commonly affected in children with juvenile idiopathic arthritis and is challenging to treat percutaneously. To describe the technique for treating the subtalar joint with US-guided corticosteroid injections in children and young adults with juvenile idiopathic arthritis and to evaluate the safety of the treatment. We retrospectively analyzed 122 patients (age 15 months-29 years) with juvenile idiopathic arthritis who were referred by a pediatric rheumatologist for corticosteroid injection therapy for symptoms related to the hindfoot or ankle. In these patients the diseased subtalar joint was targeted for therapy, often in conjunction with adjacent affected joints or tendon sheaths of the ankle. We used a protocol based on age, weight and joint for triamcinolone hexacetonide or triamcinolone acetonide dose prescription. We describe the technique for successful treatment of the subtalar joint. A total of 241 subtalar joint corticosteroid injections were performed under US guidance, including 68 repeat injections for recurrent symptoms in 26 of the 122 children and young adults. The average time interval between repeat injections was 24.8 months (range 2.2-130.7 months, median 14.2 months). Subcutaneous tissue atrophy and skin hypopigmentation were the primary complications observed. These complications occurred in 3.9% of the injections. With appropriate training and practice, the subtalar joint can be reliably and safely targeted with US-guided corticosteroid injection to treat symptoms related to juvenile idiopathic arthritis.
Analysis of "dry" mesothelioma with ultrasound guided biopsies.
Stigt, Jos A; Boers, James E; Groen, Harry J M
2012-12-01
Image-guided sampling of the thickened pleura is a sensitive approach in patients with malignant pleural mesothelioma with pleural effusion. Malignant pleural mesothelioma presenting without effusion however is more of a diagnostic challenge. In this study we report the diagnostic yield and complications of ultrasound-guided cutting needle biopsies in this particular category of patients. A retrospective database analysis from September 2007 until January 2012 was performed in 56 patients with malignant pleural mesothelioma. Clinical characteristics and results of diagnostic evaluations were analysed. Of the 56 patients with malignant pleural mesothelioma, 20 patients presented without pleural effusion of with locular effusion. Ultrasound-guided cutting needle biopsy was performed in 14/20 patients with a diagnostic accuracy of 80%. Only 1 patient had mild haemoptysis immediately following biopsies. Diagnosing patients with pleural thickenings suspect for malignant mesothelioma without pleural effusion or with loculated pleural effusion is effective and safe with ultrasound-guided cutting needle biopsies. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Ayyagari, Raj R; Yeh, Cliff; Arici, Melih; Mojibian, Hamid; Reiner, Eric; Pollak, Jeffrey S
2016-05-01
To evaluate the safety and efficacy of percutaneous transvesicular drainage of pathologic pelvic fluid collections, a series of 15 patients who underwent 16 transvesicular drainage catheter placements was retrospectively reviewed. All patients had collections suspicious for infection that were posterior to the bladder or superior to the bladder behind loops of bowel, and were otherwise inaccessible. All 15 collections were percutaneously accessed via the bladder with standard drainage catheters. All collections resolved completely with no complications. Percutaneous transvesicular drainage was a safe and effective technique in this series, and can be considered when no direct percutaneous access routes are available. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.
Ultrasound-Guided Treatment of Peripheral Nerve Pathology.
Dettori, Nathan; Choudur, Hema; Chhabra, Avneesh
2018-07-01
High-resolution ultrasound serves as a fast, accessible, reliable, and radiation-free tool for anatomical and dynamic evaluation of various peripheral nerves. It can be used not only to identify and diagnose peripheral nerve and perineural pathology accurately but also to guide various nerve and perineural interventions. We describe the normal and pathologic appearances of peripheral nerves, the pathologies commonly affecting the individual peripheral nerves, and the current ultrasound-guided peripheral nerve interventions and techniques. Future directions are also highlighted. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Impact of Focused Ultrasound-enhanced Drug Delivery on Survival in Rats with Glioma
NASA Astrophysics Data System (ADS)
Treat, Lisa Hsu; Zhang, Yongzhi; McDannold, Nathan; Hynynen, Kullervo
2009-04-01
Malignancies of the brain remain difficult to treat with chemotherapy because the selective permeability of the blood-brain barrier (BBB) blocks many potent agents from reaching their target. Previous studies have illustrated the feasibility of drug and antibody delivery across the BBB using MRI-guided focused ultrasound. In this study, we investigated the impact of focused ultrasound-enhanced delivery of doxorubicin on survival in rats with aggressive glioma. Sprague-Dawley rats were implanted with 9 L gliosarcoma cells in the brain. Eight days after implantation, each rat received one of the following: (1) no treatment (control), (2) a single treatment with microbubble-enhanced MRI-guided focused ultrasound (FUS only), (3) a single treatment with i.v. liposomal doxorubicin (DOX only), or (4) a single treatment with microbubble-enhanced MRI-guided focused ultrasound and concurrent i.v. injections of liposomal doxorubicin (FUS+DOX). The survival time from implantation to death or euthanasia was recorded. We observed a modest but significant increase in median survival time in rats treated with combined MRI-guided focused ultrasound chemotherapy, compared to chemotherapy alone (p<0.001). There was no significant improvement in survival between those who received stand-alone chemotherapy and those who did not receive any treatment (p>0.10). Our study demonstrates for the first time a therapeutic benefit achieved with ultrasound-enhanced drug delivery across the blood-brain barrier. This confirmation of efficacy in an in vivo tumor model indicates that targeted drug delivery using MRI-guided focused ultrasound has the potential to have a major impact on the treatment of patients with brain tumors and other neurological disorders.
Mahan, Angel F; McEvoy, Matthew D; Gravenstein, Nikolaus
2016-04-01
In modern practice, real-time ultrasound guidance is commonly employed for the placement of internal jugular vein catheters. With a new tool, such as ultrasound, comes the opportunity to refine and further optimize the ultrasound view during jugular vein catheterization. We describe jugular vein access techniques and use the long-axis view as an alternative to the commonly employed short-axis cross-section view for internal jugular vein access and cannulation. The long-axis ultrasound-guided internal jugular vein approach for internal jugular vein cannulation is a useful alternative technique that can provide better needle tip and guidewire visualization than the more traditional short-axis ultrasound view.
WE-G-12A-01: High Intensity Focused Ultrasound Surgery and Therapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Farahani, K; O'Neill, B
More and more emphasis is being made on alternatives to invasive surgery and the use of ionizing radiation to treat various diseases including cancer. Novel screening, diagnosis, treatment and monitoring of response to treatment are also hot areas of research and new clinical technologies. Ultrasound(US) has gained traction in all of the aforementioned areas of focus. Especially with recent advances in the use of ultrasound to noninvasively treat various diseases/organ systems. This session will focus on covering MR-guided focused ultrasound and the state of the art clinical applications, and the second speaker will survey the more cutting edge technologies e.g.more » Focused Ultrasound (FUS) mediated drug delivery, principles of cavitation and US guided FUS. Learning Objectives: Fundamental physics and physical limitations of US interaction with tissue and nanoparticles The alteration of tissue transport using focused ultrasound US control of nanoparticle drug carriers for targeted release The basic principles of MRI-guided focused ultrasound (MRgFUS) surgery and therapy the current state of the art clinical applications of MRgFUS requirements for quality assurance and treatment planning.« less
Rungsakulkij, Narongsak; Tangtawee, Pongsatorn
2017-04-20
Situs inversus totalis is a rare autosomal disorder in which the patient's affected visceral organs are a perfect mirror image of their normal positions. Surgery in these patients is technically challenging. Minimally invasive surgery such as laparoscopic cholecystectomy is the standard treatment for symptomatic cholelithiasis, but it can be difficult to perform. Laparoscopic cholecystectomy in patients with situs inversus totalis may be even more technically challenging. Fluorescence cholangiography is a new innovation in the field of navigation surgery. This procedure is safe and easy to perform, its findings are easy to interpret, and it does not require a learning curve or radiographs. It can be used in real time during surgery to identify extrahepatic biliary structures. We herein report a case of situs inversus totalis in a Thai patient with a history of biliary pancreatitis. He underwent laparoscopic cholecystectomy with intraoperative fluorescence cholangiography. The operation was successfully completed without complications. To the best of our knowledge, this is the first case report of the use of fluorescence cholangiography during laparoscopic cholecystectomy in a patient with situs inversus. Fluorescence cholangiographyis a new navigational surgical technique with which to identify extrahepatic biliary structures. It can be used as an adjunct technique during laparoscopic cholecystectomy to avoid biliary tract injury in difficult cases.
Boivin, Ariane; Nadeau, Marie-Josée; Dion, Nicolas; Lévesque, Simon; Nicole, Pierre C; Turgeon, Alexis F
2016-01-01
Single-injection ultrasound-guided infraclavicular block is a simple, reliable, and effective technique. A simplified double-injection ultrasound-guided axillary block technique with a high success rate recently has been described. It has the advantage of being performed in a superficial and compressible location, with a potentially improved safety profile. However, its effectiveness in comparison with single-injection infraclavicular block has not been established. We hypothesized that the double-injection ultrasound-guided axillary block would show rates of complete sensory block at 30 minutes noninferior to the single-injection ultrasound-guided infraclavicular block. After approval by our research ethics committee and written informed consent, adults undergoing distal upper arm surgery were randomized to either group I, ultrasound-guided single-injection infraclavicular block, or group A, ultrasound-guided double-injection axillary block. In group I, 30 mL of 1.5% mepivacaine was injected posterior to the axillary artery. In group A, 25 mL of 1.5% mepivacaine was injected posteromedial to the axillary artery, after which 5 mL was injected around the musculocutaneous nerve. Primary outcome was the rate of complete sensory block at 30 minutes. Secondary outcomes were the onset of sensory and motor blocks, surgical success rates, performance times, and incidence of complications. All outcomes were assessed by a blinded investigator. The noninferiority of the double-injection ultrasound-guided axillary block was considered if the limits of the 90% confidence intervals (CIs) were within a 10% margin of the rate of complete sensory block of the infraclavicular block. At 30 minutes, the rate of complete sensory block was 79% in group A (90% CI, 71%-85%) compared with 91% in group I (90% CI, 85%-95%); the upper limit of CI of group A is thus included in the established noninferiority margin of 10%. The rate of complete sensory block was lower in group A (proportion difference of 12% [95% CI, 2-22]; P = 0.0091), as was surgical success rate (82% [95% CI, 74%-89%] vs 93% [95% CI, 86%-97%]; proportion difference of 11% [95% CI 1-20]; P = 0.0153). Sensory block onset also was slower in group A (log rank test P = 0.0020). Performance times were faster in group I (231 seconds [95% CI, 213-250]) than in group A (358 seconds [95% CI, 332-387]; P < 0.0001). No statistically significant difference was observed for vascular puncture, paresthesia during block performance, or procedure-related pain. No neurologic complication was noted at follow-up. We failed to demonstrate that the rate of complete sensory block of the double-injection axillary block is noninferior to the single-injection infraclavicular block. However, the rate of complete sensory block at 30 minutes is statistically significantly lower with the axillary block. The ultrasound-guided single-injection infraclavicular block thus seems to be the preferred technique over the axillary for upper arm anesthesia.
Hofstad, Erlend Fagertun; Amundsen, Tore; Langø, Thomas; Bakeng, Janne Beate Lervik; Leira, Håkon Olav
2017-01-01
Background Endobronchial ultrasound transbronchial needle aspiration (EBUS-TBNA) is the endoscopic method of choice for confirming lung cancer metastasis to mediastinal lymph nodes. Precision is crucial for correct staging and clinical decision-making. Navigation and multimodal imaging can potentially improve EBUS-TBNA efficiency. Aims To demonstrate the feasibility of a multimodal image guiding system using electromagnetic navigation for ultrasound bronchoschopy in humans. Methods Four patients referred for lung cancer diagnosis and staging with EBUS-TBNA were enrolled in the study. Target lymph nodes were predefined from the preoperative computed tomography (CT) images. A prototype convex probe ultrasound bronchoscope with an attached sensor for position tracking was used for EBUS-TBNA. Electromagnetic tracking of the ultrasound bronchoscope and ultrasound images allowed fusion of preoperative CT and intraoperative ultrasound in the navigation software. Navigated EBUS-TBNA was used to guide target lymph node localization and sampling. Navigation system accuracy was calculated, measured by the deviation between lymph node position in ultrasound and CT in three planes. Procedure time, diagnostic yield and adverse events were recorded. Results Preoperative CT and real-time ultrasound images were successfully fused and displayed in the navigation software during the procedures. Overall navigation accuracy (11 measurements) was 10.0 ± 3.8 mm, maximum 17.6 mm, minimum 4.5 mm. An adequate sample was obtained in 6/6 (100%) of targeted lymph nodes. No adverse events were registered. Conclusions Electromagnetic navigated EBUS-TBNA was feasible, safe and easy in this human pilot study. The clinical usefulness was clearly demonstrated. Fusion of real-time ultrasound, preoperative CT and electromagnetic navigational bronchoscopy provided a controlled guiding to level of target, intraoperative overview and procedure documentation. PMID:28182758
Berona, Kristin; Abdi, Amin; Menchine, Michael; Mailhot, Tom; Kang, Tarina; Seif, Dina; Chilstrom, Mikaela
2017-02-01
The objectives of this study were to evaluate emergency medicine resident-performed ultrasound for diagnosis of effusions, compare the success of a landmark-guided (LM) approach with an ultrasound-guided (US) technique for hip, ankle and wrist arthrocentesis, and compare change in provider confidence with LM and US arthrocentesis. After a brief video on LM and US arthrocentesis, residents were asked to identify artificially created effusions in the hip, ankle and wrist in a cadaver model and to perform US and LM arthrocentesis of the effusions. Outcomes included success of joint aspiration, time to aspiration, and number of attempts. Residents were surveyed regarding their confidence in identifying effusions with ultrasound and performing LM and US arthrocentesis. Eighteen residents completed the study. Sensitivity of ultrasound for detecting joint effusion was 86% and specificity was 90%. Residents were successful with ultrasound in 96% of attempts and with landmark 89% of attempts (p=0.257). Median number of attempts was 1 with ultrasound and 2 with landmarks (p=0.12). Median time to success with ultrasound was 38s and 51s with landmarks (p=0.23). After the session, confidence in both US and LM arthrocentesis improved significantly, however the post intervention confidence in US arthrocentesis was higher than LM (4.3 vs. 3.8, p<0.001). EM residents were able to successfully identify joint effusions with ultrasound, however we were unable to detect significant differences in actual procedural success between the two modalities. Further studies are needed to define the role of ultrasound for arthrocentesis in the emergency department. Copyright © 2016 Elsevier Inc. All rights reserved.
Plaikner, Michaela; Gruber, Hannes; Henninger, Benjamin; Gruber, Leonhard; Kosiol, Juana; Loizides, Alexander
2016-03-01
We report on a rare case of an atypical located aneurysmal bone cyst (ABC) in the patella presenting with pathological fracture after trauma. Using all available diagnostic modalities and by means of ultrasound-guided core-needle biopsy an unclear and suspected pathological fractured cystic bone lesion in the patella of a young man could be further clarified. The acquired images suggested the diagnosis of a pathological fractured aneurysmal bone cyst after mild trauma. However, due to the extraordinary location and clinical presentation the diagnosis was secured by means of ultrasound-guided biopsy through a small cortical gap. As shown in this rare case of an atypical aneurysmal bone cyst of the patella, the quite seldom but sometimes possible ultrasound-guided biopsy of intraosseous lesions can help to achieve the diagnostic clarification and should also be taken into account as a non-standard procedure.
Filippiadis, Dimitrios K; Spiliopoulos, Stavros; Konstantos, Chrysostomos; Reppas, Lazaros; Kelekis, Alexis; Brountzos, Elias; Kelekis, Nikolaos
2017-09-03
To evaluate the clinical efficacy/safety of CT-guided percutaneous microwave ablation for HCC in challenging locations using high-power microwave platforms. A retrospective review was conducted in 26 patients with 36 HCC tumours in challenging locations (hepatic dome, subcapsular, close to the heart/diaphragm/hepatic hilum, exophytic) undergoing CT-guided percutaneous microwave ablation in a single centre since January 2011. Two different microwave platforms were used both operating at 2.45 GHz: AMICA and Acculis MWA System. Patient demographics including age, sex, tumour size and location, as well as technical details were recorded. Technical success, treatment response, patients survival and complication rate were evaluated. Treated tumours were located in the hepatic dome (n = 14), subcapsularly (n = 16), in proximity to the heart (n = 2) or liver hilum (n = 2), while two were exophytic tumours at segment VI (n = 2). Mean tumour diameter was 3.30 cm (range 1.4-5 cm). In 3/26 patients (diameter >4 cm), an additional session of DEB-TACE was performed due to tumour size. Technical success rate was 100%; complete response rate was recorded in 33/36 tumours (91.6%). According to Kaplan-Meier analysis, survival rate was 92.3% and 72.11% at 24- and 60-month follow-up, respectively. There were no major complications; two cases of minor pneumothorax and two cases of small subcapsular haematoma were resolved only with observation requiring no further treatment. CT-guided percutaneous microwave ablation for hepatocellular carcinoma tumours in challenging locations and up to 5 cm in diameter can be performed with high efficacy and safety rates.
McShane, John M; Slaff, Samantha; Gold, Judith E; Nazarian, Levon N
2012-09-01
The purpose of this study was to evaluate the effectiveness of a novel treatment procedure, sonographically guided percutaneous needle release of the carpal tunnel, for individuals with carpal tunnel syndrome. Seventeen patients (89% female; mean age, 62 years; SD, 13.6 years) with a clinical diagnosis of carpal tunnel syndrome who had undergone a sonographically guided percutaneous needle release of the carpal tunnel at least 6 months before follow-up evaluation were retrospectively reviewed. At the follow-up evaluation, to ascertain previous and current symptoms as well as functional impairment, the patients filled out a hand diagram and a questionnaire. In addition, medical records were reviewed, and patients were queried regarding complications such as infection or nerve damage. Median nerve sonographic measurements and a physical evaluation were performed on a subset of 13 patients who came to the office for evaluation. Postprocedure sonography showed that patients had a significantly smaller (P = .03) cross-sectional area of the median nerve compared to pretreatment values. In addition, patients had significantly fewer symptoms (P < .0001), less functional impairment (P = .0002), and an improved hand diagram score (P < .0001). Postprocedure patients had grip strength that was 12 lb below average (≈1 SD below) compared to grip strength norms. However, most patients (84.6%) had negative clinical diagnostic test results for carpal tunnel syndrome, and 86% said they were satisfied with the procedure. There were no procedure-related infections or nerve injuries. Of the patients with carpal tunnel syndrome who agreed to participate in this study, most had favorable symptomatic and functional outcomes. Sonographically guided percutaneous needle release of the carpal tunnel may be an alternative option to traditional surgical treatment of carpal tunnel syndrome.
McShane, John M; Nazarian, Levon N; Harwood, Marc I
2006-10-01
Chronic tendinosis of the common extensor tendon of the lateral elbow can be a difficult problem to treat. We report our experience with sonographically guided percutaneous needle tenotomy to relieve pain and improve function in patients with this condition. We performed sonographically guided percutaneous needle tenotomy on 58 consecutive patients who had persistent pain and disability resulting from common extensor tendinosis. Under a local anesthetic and sonographic guidance, a needle was advanced into the common extensor tendon, and the tip of the needle was used to repeatedly fenestrate the tendinotic tissue. Calcifications, if present, were mechanically fragmented, and the adjacent bony surface of the apex and face of the epicondyle were abraded. Finally, the fenestrated tendon was infiltrated with a solution containing corticosteroid mixed with bupivacaine. After the procedure, patients were instructed to perform passive stretches and to undergo physical therapy. During a subsequent telephone interview, patients answered questions about their experience, their functioning level, and their perceptions of procedure outcome. Fifty-five (95%) of 58 patients were contacted by telephone and agreed to participate in the study. Thirty-five (63.6%) of 55 respondents reported excellent outcomes, 16.4% good, 7.3% fair, and 12.7% poor. The average follow-up time from the date of the procedure to the date of the interview was 28 months (range, 17-44 months). No adverse events were reported; 85.5% stated that they would refer a friend or close relative for the procedure. Sonographically guided percutaneous needle tenotomy for lateral elbow tendinosis is a safe, effective, and viable alternative for patients in whom all other nonsurgical treatments failed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cazzato, Roberto Luigi, E-mail: gigicazzato@hotmail.it; Garnon, Julien, E-mail: juleiengarnon@gmail.com; Ramamurthy, Nitin, E-mail: nitin-ramamurthy@hotmail.com
ObjectiveTo describe a novel percutaneous image-guided technique using a large-bore biopsy system to retrieve foreign bodies (FBs) accidentally retained during non-vascular interventional procedures.Materials and MethodsBetween May 2013 and October 2015, five patients underwent percutaneous retrieval of five iatrogenic FBs, including a biopsy needle tip in the femoral head following osteoblastoma biopsy and radiofrequency ablation (RFA); a co-axial needle shaft within a giant desmoid tumour following cryoablation; and three post-vertebroplasty cement tails within paraspinal muscles. All FBs were retrieved immediately following original procedures under local or general anaesthesia, using combined computed tomography (CT) and fluoroscopic guidance. The basic technique involved positioningmore » a 6G trocar sleeve around the FB long axis and co-axially advancing an 8G biopsy needle to retrieve the FB within the biopsy core. Retrospective chart review facilitated analysis of procedures, FBs, technical success, and complications.ResultsMean FB size was 23 mm (range 8–74 mm). Four FBs were located within 10 mm of non-vascular significant anatomic structures. The basic technique was successful in 3 cases; 2 cases required technical modifications including using a stiff guide-wire to facilitate retrieval in the case of the post-cryoablation FB; and using the central mandrin of the 6G trocar to push a cement tract back into an augmented vertebra when initial retrieval failed. Overall technical success (FB retrieval or removal to non-hazardous location) was 100 %, with no complications.ConclusionPercutaneous image-guided retrieval of iatrogenic FBs using a large-bore biopsy system is a feasible, safe, effective, and versatile technique, with potential advantages over existing methods.« less
Ultrasound image-guided therapy enhances antitumor effect of cisplatin.
Sasaki, Noboru; Kudo, Nobuki; Nakamura, Kensuke; Lim, Sue Yee; Murakami, Masahiro; Kumara, W R Bandula; Tamura, Yu; Ohta, Hiroshi; Yamasaki, Masahiro; Takiguchi, Mitsuyoshi
2014-01-01
The aim of this study was to clarify whether ultrasound image-guided cisplatin delivery with an intratumor microbubble injection enhances the antitumor effect in a xenograft mouse model. Canine thyroid adenocarcinoma cells were used for all experiments. Before in vivo experiments, the cisplatin and microbubble concentration and ultrasound exposure time were optimized in vitro. For in vivo experiments, cells were implanted into the back of nude mice. Observed by a diagnostic ultrasound machine, a mixture of cisplatin and ultrasound contrast agent, Sonazoid, microbubbles was injected directly into tumors. The amount of injected cisplatin and microbubbles was 1 μg/tumor and 1.2 × 10(7) microbubbles/tumor, respectively, with a total injected volume of 20 μl. Using the same diagnostic machine, tumors were exposed to ultrasound for 15 s. The treatment was repeated four times. The combination of cisplatin, microbubbles, and ultrasound significantly delayed tumor growth as compared with no treatment (after 18 days, 157 ± 55 vs. 398 ± 49 mm(3), P = 0.049). Neither cisplatin alone nor the combination of cisplatin and ultrasound delayed tumor growth. The treatment did not decrease the body weight of mice. Ultrasound image-guided anticancer drug delivery may enhance the antitumor effects of drugs without obvious side effects.
The Utility of Teleultrasound to Guide Acute Patient Management.
Becker, Christian; Fusaro, Mario; Patel, Dhruv; Shalom, Isaac; Frishman, William H; Scurlock, Corey
Ultrasound has evolved into a core bedside tool for diagnostic and management purposes for all subsets of adult and pediatric critically-ill patients. Teleintensive care unit coverage has undergone a similar rapid expansion period throughout the United States. Round-the-clock access to ultrasound equipment is very common in today's intensive care unit, but 24/7 coverage with staff trained to acquire and interpret point-of-care ultrasound in real time is lagging behind equipment availability. Medical trainees and physician extenders require attending level supervision to ensure consistent image acquisition and accurate interpretation. Teleintensivists can extend the utility of ultrasound by supervising and guiding providers without or with only partial training in ultrasound, and also by extending direct trainee ultrasound supervision to time periods when no direct bedside attending supervisor is available, and when treatment decisions otherwise would have been made without supervision and feedback on image acquisition and interpretation. Nursing staff without ultrasound training can also be directed to perform basic ultrasound exams, which may have immediate diagnostic and/or treatment consequences, thereby overcoming access barriers in the absence of physicians or physician extenders. We discuss 4 real-life clinical scenarios in which teleintensivist supervision extended and standardized bedside ultrasound exams to guide management decisions which significantly impacted patient outcomes.
Feeney, Daniel A; Ober, Christopher P; Snyder, Laura A; Hill, Sara A; Jessen, Carl R
2013-01-01
Peritoneal, mesenteric, and omental diseases are important causes of morbidity and mortality in humans and animals, although information in the veterinary literature is limited. The purposes of this retrospective study were to determine whether objectively applied ultrasound interpretive criteria are statistically useful in differentiating among cytologically defined normal, inflammatory, and neoplastic peritoneal conditions in dogs and cats. A second goal was to determine the cytologically interpretable yield on ultrasound-guided, fine-needle sampling of peritoneal, mesenteric, or omental structures. Sonographic criteria agreed upon by the authors were retrospectively and independently applied by two radiologists to the available ultrasound images without knowledge of the cytologic diagnosis and statistically compared to the ultrasound-guided, fine-needle aspiration cytologic interpretations. A total of 72 dogs and 49 cats with abdominal peritoneal, mesenteric, or omental (peritoneal) surface or effusive disease and 17 dogs and 3 cats with no cytologic evidence of inflammation or neoplasia were included. The optimized, ultrasound criteria-based statistical model created independently for each radiologist yielded an equation-based diagnostic category placement accuracy of 63.2-69.9% across the two involved radiologists. Regional organ-associated masses or nodules as well as aggregated bowel and peritoneal thickening were more associated with peritoneal neoplasia whereas localized, severely complex fluid collections were more associated with inflammatory peritoneal disease. The cytologically interpretable yield for ultrasound-guided fine-needle sampling was 72.3% with no difference between species, making this a worthwhile clinical procedure. © 2013 Veterinary Radiology & Ultrasound.
Feasibility of Prostate Cancer Diagnosis by Transrectal Photo-acoustic Imaging
2013-03-01
prostate. Transrectal ultrasound has been used as a guiding tool to direct tissue needle biopsy for prostate cancer diagnosis; it cannot be utilized for...tool currently available for prostate cancer detection; needle biopsy is the current practice for diagnosis of the disease, aiming randomly in the...developing an integrated approach between ultrasound and optical tomography, namely, transrectal ultrasound - guided diffuse optical tomography (TRUS
Karmakar, M K; Li, X; Kwok, W H; Ho, A M-H; Ngan Kee, W D
2012-01-01
Objectives The use of ultrasound to guide peripheral nerve blocks is now a well-established technique in regional anaesthesia. However, despite reports of ultrasound guided epidural access via the paramedian approach, there are limited data on the use of ultrasound for central neuraxial blocks, which may be due to a poor understanding of spinal sonoanatomy. The aim of this study was to define the sonoanatomy of the lumbar spine relevant for central neuraxial blocks via the paramedian approach. Methods The sonoanatomy of the lumbar spine relevant for central neuraxial blocks via the paramedian approach was defined using a “water-based spine phantom”, young volunteers and anatomical slices rendered from the Visible Human Project data set. Results The water-based spine phantom was a simple model to study the sonoanatomy of the osseous elements of the lumbar spine. Each osseous element of the lumbar spine, in the spine phantom, produced a “signature pattern” on the paramedian sagittal scans, which was comparable to its sonographic appearance in vivo. In the volunteers, despite the narrow acoustic window, the ultrasound visibility of the neuraxial structures at the L3/L4 and L4/L5 lumbar intervertebral spaces was good, and we were able to delineate the sonoanatomy relevant for ultrasound-guided central neuraxial blocks via the paramedian approach. Conclusion Using a simple water-based spine phantom, volunteer scans and anatomical slices from the Visible Human Project (cadaver) we have described the sonoanatomy relevant for ultrasound-guided central neuraxial blocks via the paramedian approach in the lumbar region. PMID:22010025
Wong, Simon W; Niazi, Ahtsham U; Chin, Ki J; Chan, Vincent W
2013-01-01
The SonixGPS® is an electromagnetic needle tracking system for ultrasound-guided needle intervention. Both current and predicted needle tip position are displayed on the ultrasound screen in real-time, facilitating needle-beam alignment and guidance to the target. This case report illustrates the use of the SonixGPS system for successful performance of real-time ultrasound-guided spinal anesthesia in a patient with difficult spinal anatomy. A 67-yr-old male was admitted to our hospital to undergo revision of total right hip arthroplasty. His four previous arthroplasties for hip revision were performed under general anesthesia because he had undergone L3-L5 instrumentation for spinal stenosis. The L4-L5 interspace was viewed with the patient in the left lateral decubitus position. A 19G 80-mm proprietary needle (Ultrasonix Medical Corp, Richmond, BC, Canada) was inserted and directed through the paraspinal muscles to the ligamentum flavum in plane to the ultrasound beam. A 120-mm 25G Whitacre spinal needle was then inserted through the introducer needle in a conventional fashion. Successful dural puncture was achieved on the second attempt, as indicated by a flow of clear cerebrospinal fluid. The patient tolerated the procedure well, and the spinal anesthetic was adequate for the duration of the surgery. The SonixGPS is a novel technology that can reduce the technical difficulty of real-time ultrasound-guided neuraxial blockade. It may also have applications in other advanced ultrasound-guided regional anesthesia techniques where needle-beam alignment is critical.
MRI-guided focused ultrasound surgery in musculoskeletal diseases: the hot topics
Napoli, Alessandro; Sacconi, Beatrice; Battista, Giuseppe; Guglielmi, Giuseppe; Catalano, Carlo; Albisinni, Ugo
2016-01-01
MRI-guided focused ultrasound surgery (MRgFUS) is a minimally invasive treatment guided by the most sophisticated imaging tool available in today's clinical practice. Both the imaging and therapeutic sides of the equipment are based on non-ionizing energy. This technique is a very promising option as potential treatment for several pathologies, including musculoskeletal (MSK) disorders. Apart from clinical applications, MRgFUS technology is the result of long, heavy and cumulative efforts exploring the effects of ultrasound on biological tissues and function, the generation of focused ultrasound and treatment monitoring by MRI. The aim of this article is to give an updated overview on a “new” interventional technique and on its applications for MSK and allied sciences. PMID:26607640
Ultrasound and bronchoscopic controlled percutaneous tracheostomy on trauma ICU.
Kollig, E; Heydenreich, U; Roetman, B; Hopf, F; Muhr, G
2000-11-01
Tracheostomy is a common surgical procedure performed in long-term ventilated patients in intensive care. Since the role of percutaneous dilatational tracheostomy (PDT) on Intensive Care Unit (ICU) has become steadily more important in the last few years, a prospective study was started to evaluate the economic efficiency and to show the minimization of the complication rate of this procedure. In 72 patients we performed PDT as a bedside procedure. Initially the thyroid gland and the subcutaneous vessels were studied by ultrasound in every patient. The puncture of the trachea, the dilatational procedure and the insertion of the tracheal cannula were executed under bronchoscopic monitoring. Finally, a bronchoscopic control view followed via the new cannula to detect intratracheal complications. Mechanical ventilation was maintained during the procedure and controlled by continuous pulse oximetry. According to prior ultrasound findings the place to puncture the trachea was changed in 24% of the patients, in one case tracheostomy was performed as an open conventional procedure. The following complications could be observed: one case involving perforation of a cartilaginous ring, one case with venous bleeding of a small subcutaneous vein and two cases with punctures of the bronchoscope. There were no cases of miscannulation, penetration of the posterior tracheal wall or major bleeding requiring intervention or conversion. The followup study revealed that there was no sign of further complications in any patient. In addition, cost analysis demonstrated that there was a significant economical advantage of PDT in comparison with open standard tracheostomy. Standardized ultrasonographically and bronchoscopically controlled PDT turns out to be a safe, simple and cost effective bedside procedure on ICU. Because of ultrasound examination performed before the procedure, and bronchoscopic surveillance during the procedure, safety of this procedure can be enhanced, thus minimizing the rate of complications.
Outcomes of ultrasound guided renal mass biopsies.
Sutherland, Edward L; Choromanska, Agnieszka; Al-Katib, Sayf; Coffey, Mary
2018-06-01
The purpose of this study was to evaluate the rate of nondiagnostic ultrasound-guided renal mass biopsies (RMBs) at our institution and to determine what patient, procedural, and focal renal mass (FRM) factors were associated with nondiagnostic ultrasound-guided RMBs. Eighty-two ultrasound-guided renal mass biopsies performed between January 2014 and October 2016 were included in our study. Biopsy outcomes (diagnostic vs. nondiagnostic) and patient, procedural, and FRM characteristics were retrospectively reviewed and recorded. Univariate statistical analyses were performed to identify biopsy characteristics that were indicative of nondiagnostic biopsy. Ultrasound-guided RMBs were diagnostic in 70 out of 82 cases (85%) and non-diagnostic in 12 cases (15%). Among the diagnostic biopsies, 54 (77%) were malignant cases, 94% of which were renal cell carcinoma (RCC). Of the 12 nondiagnostic cases, the final diagnosis was RCC in 4 cases and angiomyolipoma in one case; seven of the nondiagnostic cases were lost to follow-up. A weak association (p = 0.04) was found between the number of needle passes and the biopsy outcome. None of the remaining collected RMB characteristics showed a significant correlation with a diagnostic or nondiagnostic RMB. Six patients (7%) experienced complications. Ultrasound-guided renal mass biopsy is a safe and effective method for the diagnosis of renal masses with a low rate of nondiagnostic outcomes. A nondiagnostic biopsy should not be treated as a surrogate for a diagnosis since a significant number of patients with nondiagnostic biopsies have subsequently been shown to have renal malignancies. Repeat biopsy should be considered in such cases.
Srinivasan, Karthikeyan Kallidaikurichi; Leo, Anne-Marie; Iohom, Gabriella; Loughnane, Frank; Lee, Peter J
2018-01-01
Background and Aims: Routine use of pre-procedural ultrasound guided midline approach has not shown to improve success rate in administering subarachnoid block. The study hypothesis was that the routine use of pre-procedural (not real time) ultrasound-guided paramedian spinals at L5-S1 interspace could reduce the number of passes (i.e., withdrawal and redirection of spinal needle without exiting the skin) required to enter the subarachnoid space when compared to the conventional landmark-guided midline approach. Methods: After local ethics approval, 120 consenting patients scheduled for elective total joint replacements (Hip and Knee) were randomised into either Group C where conventional midline approach with palpated landmarks was used or Group P where pre-procedural ultrasound was used to perform subarachnoid block by paramedian approach at L5-S1 interspace (real time ultrasound guidance was not used). Results: There was no difference in primary outcome (difference in number of passes) between the two groups. Similarly there was no difference in the number of attempts (i.e., the number of times the spinal needle was withdrawn from the skin and reinserted). The first pass success rates (1 attempt and 1 pass) was significantly greater in Group C compared to Group P [43% vs. 22%, P = 0.02]. Conclusion: Routine use of paramedian spinal anaesthesia at L5-S1 interspace, guided by pre-procedure ultrasound, in patients undergoing lower limb joint arthroplasties did not reduce the number of passes or attempts needed to achieve successful dural puncture. PMID:29416151
Rovella, Marcello S; Martins, Guilherme L P; Cavalcanti, Conrado F A; Bor-Seng-Shu, Edson; Camargo, Olavo P; Cerri, Giovanni G; Menezes, Marcos R
2016-04-01
Osteoid osteoma is painful benign tumor. The aim of this study was to report our initial experience using magnetic resonance-guided focused ultrasound to treat osteoid osteomas. This retrospective single-center study included four patients treated with magnetic resonance-guided focused ultrasound. They presented with severe pain with reduced quality of life and a poor response to clinical treatment. The pre- and post-treatment evaluation comprised computed tomography and magnetic resonance imaging and focused on quality of life and the impact of pain on daily activities. After treatment, three patients had complete pain resolution with no recurrence. One patient had a recurrence of symptoms after 2 wk and underwent a new successful treatment with increased energy levels. On average, 13 sonications were administered (8-18 sonications/treatment) with an average energy of 2,003 J (range: 1,063-3,522 J). Magnetic resonance-guided focused ultrasound appears to be a feasible, tolerable and effective treatment in selected patients with osteoid osteomas. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Percutaneous Management of Postoperative Duodenal Stump Leakage with Foley Catheter
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oh, Jung Suk, E-mail: oj-cumc@daum.net; Lee, Hae Giu, E-mail: hgleehfh@catholic.ac.kr; Chun, Ho Jong
2013-10-15
Purpose: This study was designed to evaluate retrospectively the safety and efficacy of the percutaneous management of duodenal stump leakage with a Foley catheter after subtotal gastrectomy. Methods: Ten consecutive patients (M:F = 9:1, median age: 64 years) were included in this retrospective study. The duodenal stump leakages were diagnosed in all the patients within a median of 10 days (range, 6-20). At first, the patients underwent percutaneous drainage on the day of or the day after confirmation of the presence of duodenal stump leakage, and then the Foley catheters were replaced at a median of 9 days (range, 6-38)more » after the percutaneous drainage. Results: Foley catheters were placed successfully in the duodenal lumen of all the patients under a fluoroscopic guide. No complication was observed during and after the procedures in all the patients. All of the patients started a regular diet 1 day after the Foley catheter placement. The patients were discharged at a median of 7 days (range, 5-14) after the Foley catheter placement. The catheters were removed in an outpatient clinic 10-58 days (median, 28) after the Foley catheter placement. Conclusions: Fluoroscopy-guided percutaneous Foley catheter placement may be a safe and effective treatment option for postoperative duodenal stump leakage and may allow for shorter hospital stays, earlier oral intake, and more effective control of leakage sites.« less
Amoretti, Nicolas; Huwart, Laurent; Foti, Pauline; Boileau, Pascal; Amoretti, Marie-Eve; Pellegrin, Amelie; Marcy, Pierre-Yves; Hauger, Olivier
2012-12-01
To evaluate percutaneous computed tomography (CT)-guided intracystic and intra-articular steroid injections for the treatment of lumbar facet joint cyst causing radicular pain. A single-centre prospective study involving 120 consecutive patients with symptomatic lumbar facet joint cyst-induced radicular pain was done (72 women, 48 men). The average age was 68.2 years (52-84). Patients were treated by percutaneous CT-guided intracystic and intra-articular steroid injections. The clinical course of nerve root pain was evaluated after 1 day, and 1, 3 and 6 months, with long-term follow-up after 12 months. Patient follow-ups in our series show supportive results: within 120 patients, 54% of patients were satisfied with a long-lasting result from the first intra-cystic and intra-articular steroid injections (n = 65), while 20.8% were satisfied with a long-lasting result from a second intervention. Combining these two results shows that 75% of patients were satisfied with a long-lasting result. Our results showed that percutaneous treatment of vertebral lumbar facet joint cysts by double injections is an effective and economic therapeutic technical management among 75% of our patients. Thus we recommend that it should be considered as a first choice of treatment. Lumbar facet joint cysts are a common feature of back and radicular pain. They may be treated effectively by interventional radiologists using CT guidance. Percutaneous treatment using double injections can save surgery in 75% of patients.
Patel, Bhavik N; Morgan, Madeline; Tyler, Douglas; Paulson, Erik; Jaffe, Tracy A
2015-10-01
The purpose of this study is to describe our experience with the role of CT-guided percutaneous drainage of loculated intra-abdominal collections consisting entirely of gas. An IRB-approved retrospective study analyzing patients with air-only intra-abdominal collections over an 8-year period was undertaken. Seven patients referred for percutaneous drainage were included. Size of collections, subsequent development of fluid, and microbiological yield were determined. Clinical outcome was also analyzed. Out of 2835 patients referred for percutaneous drainage between 2004 and 2012, seven patients (5M, 2F; average age 63, range 54-85) met criteria for inclusion with CT showing air-only collections. Percutaneous drain placement (five 8 Fr, one 10 Fr, and one 12 Fr) using Seldinger technique was performed. Four patients (57%) had recently undergone surgery (2 Whipple, 1 colectomy, 1 hepatic resection) while two (29%) had a remote surgery (1 abdominoperineal resection, 1 sigmoidectomy). Despite the lack of detectable fluid on the original CT, 6 patients (86%) had air and fluid aspirated at drainage, 5 (83%) of the aspirates developed positive microbacterial cultures. Four patients (57%) presented with fever at the time of the initial scan, all of whom had positive cultures from aspirated fluid. Four patients (57%) had leukocytosis, all of whom had positive cultures from aspirated fluid. Although relatively rare in occurrence, patients with air-only intra-abdominal collections with signs of infection should be considered for percutaneous management similar to that of conventional infected fluid collections. Although fluid is not visible on CT, these collections can produce fluid that contains organisms.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kroepil, Patric; Lanzman, Rotem S., E-mail: rotemshlomo@yahoo.de; Miese, Falk R.
2011-04-15
We report on percutaneous catheter procedures in the operating room (OR) to assist complicated manual extraction or insertion of pacemaker (PM) and implantable cardioverter defibrillator leads. We retrospectively reviewed complicated PM revisions and implantations performed between 2004 and 2009 that required percutaneous catheter procedures performed in the OR. The type of interventional procedure, catheter and retrieval system used, venous access, success rates, and procedural complications were analyzed. In 41 (12 female and 29 male [mean age 62 {+-} 17 years]) of 3021 (1.4%) patients, standard manual retrieval of old leads or insertion of new leads was not achievable and thusmore » required percutaneous catheter intervention for retrieval of misplaced leads and/or recanalisation of occluded central veins. Thirteen of 18 (72.2%) catheter-guided retrieval procedures for misplaced (right atrium [RA] or ventricle [RV; n = 3], superior vena cava [n = 2], brachiocephalic vein [n = 5], and subclavian vein [n = 3]) lead fragments in 16 patients were successful. Percutaneous catheter retrieval failed in five patients because there were extremely fixed or adhered lead fragments. Percutaneous transluminal angiography (PTA) of central veins for occlusion or high-grade stenosis was performed in 25 patients. In 22 of 25 patients (88%), recanalization of central veins was successful, thus enabling subsequent lead replacement. Major periprocedural complications were not observed. In the case of complicated manual PM lead implantation or revision, percutaneous catheter-guided extraction of misplaced lead fragments or recanalisation of central veins can be performed safely in the OR, thus enabling subsequent implantation or revision of PM systems in the majority of patients.« less
2015-01-01
PURPOSE To determine clinical outcomes of patients who underwent imaging-guided percutaneous drainage of breast fluid collections following mastectomy and breast reconstruction. MATERIAL AND METHODS Retrospective review included all consecutive patients who underwent percutaneous drainage of fluid collections following mastectomy with tissue expander-based reconstruction between January 2007 and September 2012. A total of 879 mastectomies (563 patients) with expander-based breast reconstruction were performed during this period. 28 patients (5%) developed fluid collections, which led to 30 imaging-guided percutaneous drainage procedures. The median follow up time was 533 days. Patient characteristics, surgical technique, microbiology analysis, and clinical outcomes were reviewed. RESULTS The mean age was 51.5 years (range 30.9 to 69.4 years) and the median time between breast reconstruction and drainage was 35 days (range 4 to 235 days). Erythema and swelling were the most common presenting symptoms. The median volume of fluid evacuated at the time of drain placement was 70 mL. Drains were left in place for a median 14 days (range 6 to 34 days). Microorganisms were detected in the fluid in 12 of 30 drainage procedures, with Staphylococcus aureus being the most common microorganism. No further intervention was needed in 21 of 30 drainage procedures (70%). However, surgical intervention (removal of expanders) was needed following 6 (20%) drainages, and additional percutaneous drainage procedures were performed following 3 (10%) drainages. CONCLUSION Percutaneous drainage is an effective means of treating post operative fluid collections after expander-based breast reconstruction and can obviate the need for repeat surgery in most cases. PMID:23810309
Transurethral ultrasound-guided laser-induced prostatectomy
NASA Astrophysics Data System (ADS)
Babayan, Richard K.; Roth, Robert A.
1991-07-01
A transurethral ultrasound-guided Nd:YAG laser delivery system has been developed for use as an alternative approach to the treatment of benign prostatic hyperplasia. The TULIP system has been extensively tested in canine models and is currently undergoing FDA trials in humans.
Bianchi, Simonetta; Bendinelli, Benedetta; Saladino, Valeria; Vezzosi, Vania; Brancato, Beniamino; Nori, Jacopo; Palli, Domenico
2015-07-01
One-hundred-fourteen consecutive cases of breast ultrasound-guided 14-gauge needle core biopsy (14G NCB) performed from January 2001 to June 2013 and diagnosed as non-malignant papillary lesion (PL)-B3, were reviewed and compared with definitive histological diagnosis on surgical excision (SE) to evaluate the diagnostic accuracy of ultrasound-guided 14G NCB. PL with epithelial atypia on 14G NCB were associated to malignancy on definitive histological diagnosis on SE in 22 (7 DCIS and 15 invasive carcinomas) of 46 cases with an underestimation rate of 47.8 %, while 9 (4 DCIS and 5 invasive carcinomas) cases out of 68 cases of PL without epithelial atypia were upgraded to carcinoma with an underestimation rate of 13.2 %. In cases of PL with epithelial atypia on ultrasound-guided 14G NCB, SE appears mandatory due to the high risk of associated malignancy. The diagnosis of PL without epithelial atypia on ultrasound-guided 14G NCB does not exclude malignancy at subsequent SE, consequently further assessment (by surgical or vacuum-assisted excision) is recommended to avoid the risk of delaying a diagnosis of malignancy, although this tends to be lower (1 in 8 patients).
[Ultrasound-guided peripheral catheterization].
Salleras-Duran, Laia; Fuentes-Pumarola, Concepció
2016-01-01
Peripheral catheterization is a technique that can be difficult in some patients. Some studies have recently described the use of ultrasound to guide the venous catheterization. To describe the success rate, time required, complications of ultrasound-guided peripheral venous catheterization. and patients and professionals satisfaction The search was performed in databases (Medline-PubMed, Cochrane Library, CINAHL and Cuiden Plus) for studies published about ultrasound-guided peripheral venous catheterization performed on patients that provided results on the success of the technique, complications, time used, patient satisfaction and the type of professional who performed the technique. A total of 21 studies were included. Most of them get a higher success rate 80% in the catheterization ecoguide and time it is not higher than the traditional technique. The Technical complications analyzed were arterial puncture rates and lower nerve 10%. In all studies measuring and comparing patient satisfaction in the art ecoguide is greater. Various professional groups perform the technique. The use of ultrasound for peripheral pipes has a high success rate, complications are rare and the time used is similar to that of the traditional technique. The technique of inserting catheters through ultrasound may be learned by any professional group performing venipuncture. Finally, it gets underscores the high patient satisfaction with the use of this technique. Copyright © 2015 Elsevier España, S.L.U. All rights reserved.
Finnoff, Jonathan T; Hall, Mederic M; Adams, Erik; Berkoff, David; Concoff, Andrew L; Dexter, William; Smith, Jay
2015-02-01
The use of diagnostic and interventional ultrasound has significantly increased over the past decade. A majority of the increased utilisation is by non-radiologists. In sports medicine, ultrasound is often used to guide interventions such as aspirations, diagnostic or therapeutic injections, tenotomies, releases and hydrodissections. Critically review the literature related to the accuracy, efficacy and cost-effectiveness of ultrasound-guided injections (USGIs) in major, intermediate and small joints; and soft tissues. Systematic review of the literature. USGIs are more accurate than landmark-guided injections (LMGIs; strength of recommendation taxonomy (SORT) Evidence Rating=A). USGIs are more efficacious than LMGIs (SORT Evidence Rating=B). USGIs are more cost-effective than LMGIs (SORT Evidence Rating=B). Ultrasound guidance is required to perform many new procedures (SORT Evidence Rating=C). The findings of this position statement indicate there is strong evidence that USGIs are more accurate than LMGI, moderate evidence that they are more efficacious and preliminary evidence that they are more cost-effective. Furthermore, ultrasound-guided (USG) is required to perform many new, advanced procedures and will likely enable the development of innovative USG surgical techniques in the future. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Ultrasound-guided supraclavicular block: outcome of 510 consecutive cases.
Perlas, Anahi; Lobo, Giovanni; Lo, Nick; Brull, Richard; Chan, Vincent W S; Karkhanis, Reena
2009-01-01
Supraclavicular brachial plexus block provides consistently effective anesthesia to the upper extremity. However, traditional nerve localization techniques may be associated with a high risk of pneumothorax. In the present study, we report block success and clinical outcome data from 510 consecutive patients who received an ultrasound-guided supraclavicular block for upper extremity surgery. After institutional review board approval, the outcome of 510 consecutive patients who received an ultrasound-guided supraclavicular block for upper extremity surgery was reviewed. Real-time ultrasound guidance was used with a high-frequency linear probe. The neurovascular structures were imaged on short axis, and the needle was inserted using an in-plane technique with either a medial-to-lateral or lateral-to-medial orientation. Five hundred ten ultrasound-guided supraclavicular blocks were performed (50 inpatients, 460 outpatients) by 47 different operators at different levels of training over a 24-month period. Successful surgical anesthesia was achieved in 94.6% of patients after a single attempt; 2.8% required local anesthetic supplementation of a single peripheral nerve territory; and 2.6% received an unplanned general anesthetic. No cases of clinically symptomatic pneumothorax developed. Complications included symptomatic hemidiaphragmatic paresis (1%), Horner syndrome (1%), unintended vascular punctures (0.4%), and transient sensory deficits (0.4%). Ultrasound-guided supraclavicular block is associated with a high rate of successful surgical anesthesia and a low rate of complications and thus may be a safe alternative for both inpatients and outpatients. Severe underlying respiratory disease and coagulopathy should remain a contraindication for this brachial plexus approach.
Lee, Jae Jun; Hwang, Jung-Taek; Kim, Do-Young; Lee, Sang-Soo; Hwang, Sung Mi; Lee, Na Rea; Kwak, Byung-Chan
2017-07-01
The aim of this study was to compare the pain relieving effect of ultrasound-guided interscalene brachial plexus block (ISB) combined with arthroscopy-guided suprascapular nerve block (SSNB) with that of ultrasound-guided ISB alone within the first 48 h after arthroscopic rotator cuff repair. Forty-eight patients with rotator cuff tears who had undergone arthroscopic rotator cuff repair were enrolled. The 24 patients in group 1 received ultrasound-guided ISB and arthroscopy-guided SSNB; the remaining 24 patients in group 2 underwent ultrasound-guided ISB alone. Visual analogue scale pain score and patient satisfaction score were checked at 1, 3, 6, 12, 18, 24, and 48 h post-operatively. Group 1 had a lower visual analogue scale pain score at 3, 6, 12, 18, 24, and 48 h post-operatively (1.7 < 2.6, 1.6 < 4.0, 3.5 < 5.8, 3.6 < 5.2, 3.2 < 4.2, 1.3 < 2.0), and a higher patient satisfaction score at 6, 12, 18, 24, and 36 h post-operatively than group 2 (7.8 > 6.0, 6.2 > 4.3, 6.4 > 5.1, 6.9 > 5.9, 7.9 > 7.1). Six patients in group 1 developed rebound pain twice, and the others in group 1 developed it once. All of the patients in group 2 had one rebound phenomenon each (p = 0.010). The mean timing of rebound pain in group 1 was later than that in group 2 (15.5 > 9.3 h, p < 0.001), and the mean size of rebound pain was smaller in group 1 than that in group 2 (2.5 > 4.0, p = 0.001). Arthroscopy-guided SSNB combined with ultrasound-guided ISB resulted in lower visual analogue scale pain scores at 3-24 and 48 h post-operatively, and higher patient satisfaction scores at 6-36 h post-operatively with the attenuated rebound pain compared to scores in patients who received ultrasound-guided ISB alone after arthroscopic rotator cuff repair. The combined blocks may relieve post-operative pain more effectively than the single block within 48 h after arthroscopic cuff repair. Randomized controlled trial, Level I. ClinicalTrials.gov Identifier: NCT02424630.
Bigeleisen, Paul E
2017-05-15
Needle guides may allow the practitioner to align the needle with the probe when ultrasound-guided nerve block is performed. The author's goal was to design and fabricate an inexpensive ($1.90), disposable, needle guide that could articulate over a range from 85 degrees to 0 degrees with a three-dimension printer. Three-dimensional representations of an L50, L25, and C 60 ultrasound probe (Sono Site, Bothell, WA) were created using a laser scanner. Computer-aided design software (Solid Works, Waltham, MA) was used to design a needle bracket and needle guide to attach to these probes. A three-dimensional printer was used to fabricate the needle bracket and guide with acrylonitrile polybutadiene polystyrene. An echogenic needle was held in plane with the needle guide. The author performed a supraclavicular block in a morbidly obese patient. The needle was easily visualized. Similar guides that are commercially available cost as much as $400. A knowledge of computer-aided design is necessary for this work.
Mini access guide to simplify calyceal access during percutaneous nephrolithotomy: A novel device.
Chowdhury, Puskar Shyam; Nayak, Prasant; David, Deepak; Mallick, Sujata
2017-01-01
A precise puncture of the renal collecting system is the most essential step for percutaneous nephrolithotomy (PCNL). There are many techniques describing this crucial first step in PCNL including the bull's eye technique, triangulation technique, free-hand technique, and gradual descensus technique. We describe a novel puncture guide to assist accurate percutaneous needle placement during bull's eye technique. The mini access guide (MAG) stabilizes the initial puncture needle by mounting it on an adjustable multidirectional carrier fixed to the patient's skin, which aids in achieving the "bull's eye" puncture. It also avoids a direct fluoroscopic exposure of the urologist's hand during the puncture. Sixty consecutive patients with solitary renal calculus were randomized to traditional hand versus MAG puncture during bull's eye technique of puncture and the fluoroscopy time was assessed. The median fluoroscopy screening time for traditional free-hand bull's eye and MAG-guided bull's eye puncture (fluoroscopic screening time for puncture) was 55 versus 21 s ( P = 0.001) and the median time to puncture was 80 versus 55 s ( P = 0.052), respectively. Novice residents also learned puncture technique faster with MAG on simulator. The MAG is a simple, portable, cheap, and novel assistant to achieve successful PCNL puncture. It would be of great help for novices to establish access during their learning phase of PCNL. It would also be an asset toward significantly decreasing the radiation dose during PCNL access.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kelogrigoris, M., E-mail: kelogre.mic@hotmail.com; Sotiropoulou, E.; Stathopoulos, K.
This study was designed to evaluate the efficacy and safety of computed tomography (CT)-guided drainage in treating infected collections due to gastric leak after laparoscopic sleeve gastrectomy for morbid obesity. From January 2007 to June 2009, 21 patients (9 men and 12 women; mean age, 39.2 (range, 26-52) years) with infected collections due to gastric leak after laparoscopic sleeve gastrectomy for morbid obesity underwent image-guided percutaneous drainage. All procedures were performed using CT guidance and 8- to 12-Fr pigtail drainage catheters. Immediate technical success was achieved in all 21 infected collections. In 18 of 21 collections, we obtained progressive shrinkagemore » of the collection with consequent clinical success (success rate 86%). In three cases, the abdominal fluid collection was not resolved, and the patients were reoperated. Among the 18 patients who avoided surgery, 2 needed replacement of the catheter due to obstruction. No major complications occurred during the procedure. The results of our study support that CT-guided percutaneous drainage is an effective and safe method to treat infected abdominal fluid collections due to gastric leak in patients who had previously underwent laparoscopic sleeve gastrectomy for morbid obesity. It may be considered both as a preparatory step for surgery and a valuable alternative to open surgery. Failure of the procedure does not, however, preclude a subsequent surgical operation.« less
Minimally Invasive Ultrasound-Guided Carpal Tunnel Release: Preliminary Clinical Results.
Henning, P Troy; Yang, Lynda; Awan, Tariq; Lueders, Daniel; Pourcho, Adam M
2018-04-02
Ultrasound-guided carpal tunnel release was performed on 14 patients (18 wrists) using dynamic expansion of the transverse safe zone. Our patient population included able-bodied patients and those with impairments. The first 8 cases (12 wrists) underwent the procedure in an operating room, the remainder in an outpatient setting. No complications occurred, and all patients were able to immediately resume use of their hands without therapy. Improvements in the Quick Form of the Disabilities of the Arm, Shoulder, and Hand Index and Boston Carpal Tunnel Questionnaire at 3 months were comparable to results reported with mini-open and endoscopic release. Our results show that ultrasound-guided carpal tunnel release can be safely and effectively performed in an outpatient setting. © 2018 by the American Institute of Ultrasound in Medicine.
Propogation loss with frequency of ultrasound guided waves in a composite metal-honeycomb structure
NASA Astrophysics Data System (ADS)
Saxena, Indu F.; Baid, Harsh K.; Guzman, Narciso; Kempen, Lothar U.; Mal, Ajit
2009-05-01
Non-destructive testing of critical structural components is time consuming, while necessary for maintaining safe operation. Large aerospace structures, such as the vertical stabilizers of aircraft undergo inspection at regular intervals for damage diagnostics. However, conventional techniques for damage detection and identification before repair can be scheduled are conducted off-line and therefore can take weeks. The use of guided ultrasound waves is being investigated to expedite damage detection in composites. We measure the frequency dependent loss of ultrasonic guided waves for a structure comprising a boron-nitride composite skin sandwiching an aluminum honeycomb. A wide range of ultrasound frequencies propagate as measured using PZTs, with the lowest attenuation observed about 200-250 kHz. These measurements are confirmed using optical fiber Bragg grating arrays used as ultrasound transducers.
Dillenseger, Jean-Louis; Esneault, Simon; Garnier, Carole
2008-01-01
This paper describes a modeling method of the tissue temperature evolution over time in hyperthermia. More precisely, this approach is used to simulate the hepatocellular carcinoma curative treatment by a percutaneous high intensity ultrasound surgery. The tissue temperature evolution over time is classically described by Pennes' bioheat transfer equation which is generally solved by a finite difference method. In this paper we will present a method where the bioheat transfer equation can be algebraically solved after a Fourier transformation over the space coordinates. The implementation and boundary conditions of this method will be shown and compared with the finite difference method.
Park, Gi-Young; Kwon, Dong Rak; Lee, Sang Chul
2015-11-01
Rotator cuff tendon tear is one of the most common causes of chronic shoulder pain and disability. In this study, we investigated the therapeutic effects of ultrasound-guided human umbilical cord blood (UCB)-derived mesenchymal stem cell (MSC) injection to regenerate a full-thickness subscapularis tendon tear in a rabbit model by evaluating the gross morphology and histology of the injected tendon and motion analysis of the rabbit's activity. At 4 weeks after ultrasound-guided UCB-derived MSC injection, 7 of the 10 full-thickness subscapularis tendon tears were only partial-thickness tears, and 3 remained full-thickness tendon tears. The tendon tear size and walking capacity at 4 weeks after UCB-derived MSC injection under ultrasound guidance were significantly improved compared with the same parameters immediately after tendon tear. UCB-derived MSC injection under ultrasound guidance without surgical repair or bioscaffold resulted in the partial healing of full-thickness rotator cuff tendon tears in a rabbit model. Histology revealed that UCB-derived MSCs induced regeneration of rotator cuff tendon tear and that the regenerated tissue was predominantly composed of type I collagens. In this study, ultrasound-guided injection of human UCB-derived MSCs contributed to regeneration of the full-thickness rotator cuff tendon tear without surgical repair. The results demonstrate the effectiveness of local injection of MSCs into the rotator cuff tendon. The results of this study suggest that ultrasound-guided umbilical cord blood-derived mesenchymal stem cell injection may be a useful conservative treatment for full-thickness rotator cuff tendon tear repair. ©AlphaMed Press.
Park, Gi-Young; Lee, Sang Chul
2015-01-01
Rotator cuff tendon tear is one of the most common causes of chronic shoulder pain and disability. In this study, we investigated the therapeutic effects of ultrasound-guided human umbilical cord blood (UCB)-derived mesenchymal stem cell (MSC) injection to regenerate a full-thickness subscapularis tendon tear in a rabbit model by evaluating the gross morphology and histology of the injected tendon and motion analysis of the rabbit’s activity. At 4 weeks after ultrasound-guided UCB-derived MSC injection, 7 of the 10 full-thickness subscapularis tendon tears were only partial-thickness tears, and 3 remained full-thickness tendon tears. The tendon tear size and walking capacity at 4 weeks after UCB-derived MSC injection under ultrasound guidance were significantly improved compared with the same parameters immediately after tendon tear. UCB-derived MSC injection under ultrasound guidance without surgical repair or bioscaffold resulted in the partial healing of full-thickness rotator cuff tendon tears in a rabbit model. Histology revealed that UCB-derived MSCs induced regeneration of rotator cuff tendon tear and that the regenerated tissue was predominantly composed of type I collagens. In this study, ultrasound-guided injection of human UCB-derived MSCs contributed to regeneration of the full-thickness rotator cuff tendon tear without surgical repair. The results demonstrate the effectiveness of local injection of MSCs into the rotator cuff tendon. Significance The results of this study suggest that ultrasound-guided umbilical cord blood-derived mesenchymal stem cell injection may be a useful conservative treatment for full-thickness rotator cuff tendon tear repair. PMID:26371340
Jeon, Yunseok; Choi, Seungpyo; Kim, Heechan
2014-09-01
To investigate whether a novel ultrasound device may be used with a simplified augmented reality technique, and to compare this device with conventional techniques during vascular access using a vascular phantom. Prospective, randomized study. Anesthesiology and Pain Medicine departments of a university-affiliated hospital. 20 physicians with no experience with ultrasound-guided techniques. All participants performed the vascular access technique on the vascular phantom model using both a conventional device and the new ultrasound device. Time and the number of redirections of the needle until aspiration of dye into a vessel of the vascular phantom were measured. The median/interquartile range of time was 39.5/41.7 seconds versus 18.6/10.0 seconds (P < 0.001) and number of redirections was 3/3.5 versus 1/0 (P < 0.001) for the conventional and novel ultrasound devices, respectively. During vascular access in a vascular phantom model, the novel device decreased the time and the number of redirections significantly. The device successfully improved the efficiency of the ultrasound-guided vascular access technique. Copyright © 2014 Elsevier Inc. All rights reserved.
Ultrasound-guided microwave ablation in the treatment of benign thyroid nodules in 435 patients
Qian, Lin-Xue; Liu, Dong; Zhao, Jun-Feng
2017-01-01
The objective of the present study was to investigate the effectiveness and safety of ultrasound-guided microwave ablation in the treatment of benign thyroid nodules. A total of 474 benign thyroid nodules in 435 patients who underwent ultrasound-guided microwave ablation from September 2012 to August 2015 were included. Nodule volume and thyroid function were measured before treatment and at 1, 3, 6, and 12 months and subsequently after every 6 months. The nodule volume reduction rate and changes of thyroid function were evaluated. The volume of all thyroid nodules significantly decreased after ultrasound-guided microwave ablation. The average volume was 13.07 ± 0.95 ml before treatment, and 1.14 ± 0.26 ml at 12-months follow-up. The mean volume reduction rate was 90% and the final volume reduction rate was 94%. The volume reduction rate of mainly cystic nodules was significantly higher than that of simple solid and mainly solid nodules (all P < 0.05). The pretreatment volume of nodules was positively correlated with the final volume reduction rate at final follow-up (P = 0.004). No serious complications were observed after treatment. In conclusion, ultrasound-guided microwave ablation is an effective and safe technique for treatment of benign thyroid nodules, and has the potential for clinical applications. Impact statement Ultrasound-guided MWA is an effective and safe technique for the treatment of benign thyroid nodules. It can significantly reduce the nodule volume, improve the patients’ clinical symptoms, has less complication, guarantees quick recovery, meets patients' aesthetic needs, and shows less interference on the physiological and psychological aspects of the body. MWA should be a good complement to traditional open surgery and has potentials in clinical applications. PMID:28847173
Ultrasound-guided microwave ablation in the treatment of benign thyroid nodules in 435 patients.
Liu, Yu-Jiang; Qian, Lin-Xue; Liu, Dong; Zhao, Jun-Feng
2017-09-01
The objective of the present study was to investigate the effectiveness and safety of ultrasound-guided microwave ablation in the treatment of benign thyroid nodules. A total of 474 benign thyroid nodules in 435 patients who underwent ultrasound-guided microwave ablation from September 2012 to August 2015 were included. Nodule volume and thyroid function were measured before treatment and at 1, 3, 6, and 12 months and subsequently after every 6 months. The nodule volume reduction rate and changes of thyroid function were evaluated. The volume of all thyroid nodules significantly decreased after ultrasound-guided microwave ablation. The average volume was 13.07 ± 0.95 ml before treatment, and 1.14 ± 0.26 ml at 12-months follow-up. The mean volume reduction rate was 90% and the final volume reduction rate was 94%. The volume reduction rate of mainly cystic nodules was significantly higher than that of simple solid and mainly solid nodules (all P < 0.05). The pretreatment volume of nodules was positively correlated with the final volume reduction rate at final follow-up ( P = 0.004). No serious complications were observed after treatment. In conclusion, ultrasound-guided microwave ablation is an effective and safe technique for treatment of benign thyroid nodules, and has the potential for clinical applications. Impact statement Ultrasound-guided MWA is an effective and safe technique for the treatment of benign thyroid nodules. It can significantly reduce the nodule volume, improve the patients' clinical symptoms, has less complication, guarantees quick recovery, meets patients' aesthetic needs, and shows less interference on the physiological and psychological aspects of the body. MWA should be a good complement to traditional open surgery and has potentials in clinical applications.
Ultrasound-guided synovial Tru-cut biopsy: indications, technique, and outcome in 111 cases.
Sitt, Jacqueline C M; Griffith, James F; Lai, Fernand M; Hui, Mamie; Chiu, K H; Lee, Ryan K L; Ng, Alex W H; Leung, Jason
2017-05-01
To investigate the diagnostic performance of ultrasound-guided synovial biopsy. Clinical notes, pathology and microbiology reports, ultrasound and other imaging studies of 100 patients who underwent 111 ultrasound-guided synovial biopsies were reviewed. Biopsies were compared with the final clinical diagnosis established after synovectomy (n = 43) or clinical/imaging follow-up (n = 57) (mean 30 months). Other than a single vasovagal episode, no complication of synovial biopsy was encountered. One hundred and seven (96 %) of the 111 biopsies yielded synovium histologically. Pathology ± microbiology findings for these 107 conclusive biopsies comprised synovial tumour (n = 30, 28 %), synovial infection (n = 18, 17 %), synovial inflammation (n = 45, 42 %), including gouty arthritis (n = 3), and no abnormality (n = 14, 13 %). The accuracy, sensitivity, and specificity of synovial biopsy was 99 %, 97 %, and 100 % for synovial tumour; 100 %, 100 %, and 100 % for native joint infection; and 78 %, 45 %, and 100 % for prosthetic joint infection. False-negative synovial biopsy did not seem to be related to antibiotic therapy. Ultrasound-guided Tru-cut synovial biopsy is a safe and reliable technique with a high diagnostic yield for diagnosing synovial tumour and also, most likely, for joint infection. Regarding joint infection, synovial biopsy of native joints seems to have a higher diagnostic yield than that for infected prosthetic joints. • Ultrasound-guided Tru-cut synovial biopsy has high accuracy (99 %) for diagnosing synovial tumour. • It has good accuracy, sensitivity, and high specificity for diagnosis of joint infection. • Synovial biopsy of native joints works better than biopsy of prosthetic joints. • A negative synovial biopsy culture from a native joint largely excludes septic arthritis. • Ultrasound-guided Tru-cut synovial biopsy is a safe and well-tolerated procedure.
Piana, Simonetta; Riganti, Fabrizio; Froio, Elisabetta; Andrioli, Massimiliano; Pacella, Claudio M; Valcavi, Roberto
2012-06-01
Ultrasound (US)-guided percutaneous laser ablation (LA) of benign thyroid nodules may be a potential alternative to surgery in patients with compressive symptoms, at high surgical risk, or in patients who refuse to undergo surgery. We evaluated the morphological effects of LA procedure on 22 patients and compared the cytological findings before and after LA with the histological features on surgical specimens. Twenty-two (4.9%; 19 women, three men, mean age 53.2 years) out of 452 patients treated with LA for benign thyroid nodules in our Hospital underwent surgery after LA procedure, either because nodule regrowth (treatment failure, n = 17) or indeterminate cytology (Thy3) after LA (n = 5). Morphological findings varied according to the time between LA and surgical intervention. Within 2 months, the area was occasionally cavitated and filled in with dark amorphous material. The inflammatory response was abundant and composed of neutrophils, lymphocytes, and macrophages. After 18 months or more since LA, the expected laser-induced histologic changes in thyroid morphology consisted of a well-defined area surrounded by a fibrous capsule and filled in by amorphous material. No significant pathologic features were found in the thyroid tissue adjacent to the treated area. Histological evaluation of thyroid tissues after LA shows that thermal damage is restricted to the ablated area, with no involvement of the nearby parenchyma. Our long-term histopathological findings indicate that LA treatment of benign thyroid nodules is safe, and patients undergoing LA may also be followed up by fine needle aspiration.
Kang, Tae Wook; Lee, Min Woo; Song, Kyoung Doo; Kim, Mimi; Kim, Seung Soo; Kim, Seong Hyun; Ha, Sang Yun
2017-01-01
To assess whether contrast-enhanced ultrasonography (CEUS) with Sonazoid can improve the lesion conspicuity and feasibility of percutaneous biopsies for focal hepatic lesions invisible on fusion imaging of real-time ultrasonography (US) with computed tomography/magnetic resonance images, and evaluate its impact on clinical decision making. The Institutional Review Board approved this retrospective study. Between June 2013 and January 2015, 711 US-guided percutaneous biopsies were performed for focal hepatic lesions. Biopsies were performed using CEUS for guidance if lesions were invisible on fusion imaging. We retrospectively evaluated the number of target lesions initially invisible on fusion imaging that became visible after applying CEUS, using a 4-point scale. Technical success rates of biopsies were evaluated based on histopathological results. In addition, the occurrence of changes in clinical decision making was assessed. Among 711 patients, 16 patients (2.3%) were included in the study. The median size of target lesions was 1.1 cm (range, 0.5-1.9 cm) in pre-procedural imaging. After CEUS, 15 of 16 (93.8%) focal hepatic lesions were visualized. The conspicuity score was significantly increased after adding CEUS, as compared to that on fusion imaging (p < 0.001). The technical success rate of biopsy was 87.6% (14/16). After biopsy, there were changes in clinical decision making for 11 of 16 patients (68.8%). The addition of CEUS could improve the conspicuity of focal hepatic lesions invisible on fusion imaging. This dual guidance using CEUS and fusion imaging may affect patient management via changes in clinical decision-making.
Liu, Wei-hui; Wang, Tao; Yan, Hong-tao; Chen, Tao; Xu, Chuan; Ye, Ping; Zhang, Ning; Liu, Zheng-cai; Tang, Li-jun
2015-01-01
Aims Although we previously demonstrated abdominal paracentesis drainage (APD) preceding percutaneous catheter drainage (PCD) as the central step for treating patients with moderately severe (MSAP) or severe acute pancreatitis (SAP), the predictors leading to PCD after APD have not been studied. Methods Consecutive patients with MSAP or SAP were recruited between June 2011 and June 2013. As a step-up approach, all patients initially received medical management, later underwent ultrasound-guided APD before PCD, if necessary, followed by endoscopic necrosectomy through the path formed by PCD. APD primarily targeted fluid in the abdominal or pelvic cavities, whereas PCD aimed at (peri)pancreatic fluid. Results Of the 92 enrolled patients, 40 were managed with APD alone and 52 received PCD after APD (14 required necrosectomy after initial PCD). The overall mortality was 6.5%. Univariate analysis showed that among the 20 selected parameters, 13 factors significantly affected PCD intervention after APD. Multivariate analysis revealed that infected (peri)pancreatic collections (P = -0.001), maximum extent of necrosis of more than 30% of the pancreas (P = -0.024), size of the largest necrotic peri(pancreatic) collection (P = -0.007), and reduction of (peri)pancreatic fluid collections by <50% after APD (P = -0.008) were all independent predictors of PCD. Conclusions Infected (peri)pancreatic collections, a largest necrotic peri(pancreatic) collection of more than 100 ml, and reduction of (peri)pancreatic fluid collections by <50% after APD could effectively predict the need for PCD in the early course of the disease. PMID:25659143
Wang, Hang; Li, Qinggang; Liu, Juan; Mendelsohn, Cathy; Salant, David J.; Lu, Weining
2011-01-01
Antenatal hydronephrosis and vesicoureteral reflux (VUR) are common renal tract birth defects. We recently showed that disruption of the Robo2 gene is associated with VUR in humans and antenatal hydronephrosis in knockout mice. However, the natural history, causal relationship and developmental origins of these clinical conditions remain largely unclear. Although the hydronephrosis phenotype in Robo2 knockout mice has been attributed to the coexistence of ureteral reflux and obstruction in the same mice, this hypothesis has not been tested experimentally. Here we used noninvasive high-resolution micro-ultrasonography and pathological analysis to follow the progression of antenatal hydronephrosis in individual Robo2-deficient mice from embryo to adulthood. We found that hydronephrosis progressed continuously after birth with no spontaneous resolution. With the use of a microbubble ultrasound contrast agent and ultrasound-guided percutaneous aspiration, we demonstrated that antenatal hydronephrosis in Robo2-deficient mice is caused by high-grade VUR resulting from a dilated and incompetent ureterovesical junction rather than ureteral obstruction. We further documented Robo2 expression around the developing ureterovesical junction and identified early dilatation of ureteral orifice structures as a potential fetal origin of antenatal hydronephrosis and VUR. Our results thus demonstrate that Robo2 is crucial for the formation of a normal ureteral orifice and for the maintenance of an effective anti-reflux mechanism. This study also establishes a reproducible genetic mouse model of progressive antenatal hydronephrosis and primary high-grade VUR. PMID:21949750
3D ultrasound imaging in image-guided intervention.
Fenster, Aaron; Bax, Jeff; Neshat, Hamid; Cool, Derek; Kakani, Nirmal; Romagnoli, Cesare
2014-01-01
Ultrasound imaging is used extensively in diagnosis and image-guidance for interventions of human diseases. However, conventional 2D ultrasound suffers from limitations since it can only provide 2D images of 3-dimensional structures in the body. Thus, measurement of organ size is variable, and guidance of interventions is limited, as the physician is required to mentally reconstruct the 3-dimensional anatomy using 2D views. Over the past 20 years, a number of 3-dimensional ultrasound imaging approaches have been developed. We have developed an approach that is based on a mechanical mechanism to move any conventional ultrasound transducer while 2D images are collected rapidly and reconstructed into a 3D image. In this presentation, 3D ultrasound imaging approaches will be described for use in image-guided interventions.
Lam, Nicholas C K; Baker, Elizabeth B; Fishburn, Steven J; Hammer, Angie R; Petersen, Timothy R; Mariano, Edward R
2016-07-01
Learning ultrasound-guided regional anesthesia skills, especially needle/ beam alignment, can be especially difficulty for trainees, who can often become frustrated. We hypothesized that teaching novices to orient the transducer and needle perpendicular to their shoulders will improve performance on a standardized task, compared to holding the transducer and needle parallel to the shoulders. This study compared the effects of transducer orientation on trainees' ability to complete a standardized ultrasound-guided nerve block simulation. The time to task completion and percentage of the attempt time without adequate needle visualization were measured. Participants were right-handed healthy adults with no previous ultrasound experience and were randomly assigned to training in either transducer and needle alignment in a coronal plane, parallel to the shoulders (parallel group) or transducer and needle alignment in a sagittal plane, perpendicular to the shoulders (perpendicular group). Participants used ultrasound to direct a needle to 3 targets in a standardized gelatin phantom and repeated this task 3 times. Their efforts were timed and evaluated by an assessor, who was blinded to group assignment. Data were analyzed on 28 participants. The perpendicular group was able to complete the task more quickly (P < .001) and with a smaller proportion of time lost to inadequate needle visualization (P < .001). Ultrasound-guided regional anesthesia trainees complete a standardized task more quickly and efficiently when instructed to hold the transducer and needle in an orientation perpendicular to their shoulders.
Ülger, Fatma Esra Bahadır; Ülger, Aykut; Karakaya, Ali Erdal; Tüten, Fatih; Katı, Ömer; Çolak, Mustafa
2014-03-01
Intussusception is one of the important causes of intestinal obstruction in children. Hydrostatic reduction under ultrasound guidance is a popular treatment method for intussusception. In the present study, we aimed to explain the demographic characteristics of and treatment approaches in patients diagnosed with intussusception by ultrasound. Forty-one patients diagnosed with intussusception by ultrasound between August 2011 and May 2013 were retrospectively analyzed. Twenty-four of these patients who had no contraindications had been treated with ultrasound-guided hydrostatic reduction. Twenty-four of the patients were male and 17 were female, a 1.4/1 male-to-female ratio. The majority of the patients were between the ages of 6-24 months and 2-5 years. The mean age was 31.12±26.32 months (range 3-125). Patients were more frequently diagnosed in April and May. Seventeen patients who had clinical contraindications enrolled directly for surgery. In 20 of the 24 patients who underwent ultrasound-guided hydrostatic reduction, reduction was achieved. Three experienced recurrence. In two of these patients, successful reduction was achieved with the second attempt. The remaining patient was enrolled for surgery. Hydrostatic reduction was performed 26 times on these 24 patients, and in 22, success was achieved (84.6%). No procedure-related complications occurred in the patients. Ultrasound-guided hydrostatic reduction, with its high success rates and lack of radiation risk, should be the first choice therapeutic approach for children diagnosed with intussusception.
CT guided interstitial therapy of pancreatic carcinoma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Haaga, J.R.; Owens, D.B.; Kellermeyer, R.W.
1987-11-01
We describe the use of percutaneous CT guidance for localization and placement of /sup 192/Ir sources into a patient with pancreatic carcinoma. We have shown the feasibility of this procedure and the lack of complications which are probably due to minimal damage to tissue involved. Computed tomography is ideally suited for percutaneous implantation because it provides the most accurate method for needle placement within the abdomen.
Mignon, Paul; Poignet, Philippe; Troccaz, Jocelyne
2018-05-29
Robotic control of needle bending aims at increasing the precision of percutaneous procedures. Ultrasound feedback is preferable for its clinical ease of use, cost and compactness but raises needle detection issues. In this paper, we propose a complete system dedicated to robotized guidance of a flexible needle under 3D ultrasound imaging. This system includes a medical robot dedicated to transperineal needle positioning and insertion, a rapid path planning for needle steering using bevel-tip needle natural curvature in tissue, and an ultrasound-based automatic needle detection algorithm. Since ultrasound-based automatic needle steering is often made difficult by the needle localization in biological tissue, we quantify the benefit of using flexible echogenic needles for robotized guidance under 3D ultrasound. The "echogenic" term refers to the etching of microstructures on the needle shaft. We prove that these structures improve needle visibility and detection robustness in ultrasound images. We finally present promising results when reaching targets using needle steering. The experiments were conducted with various needles in different media (synthetic phantoms and ex vivo biological tissue). For instance, with nitinol needles the mean accuracy is 1.2 mm (respectively 3.8 mm) in phantoms (resp. biological tissue).
Hong, Hyun Pyo; Kim, Seung Kwon
2009-11-01
The purpose of this study was to assess the usefulness of percutaneous intervention with transarterial approach in the salvage of nonmaturing native fistulas status post transvenous approach failure. Eight patients (M:F=2:6; mean age, 56.8 years) underwent percutaneous intervention with antegrade transarterial approach when the retrograde transvenous approach failed. Mean time from fistula creation to fistulography was 80.5 days. Five patients had brachiocephalic fistulas and three had radiocephalic fistulas. Brachial or radial arterial access was performed using real-time ultrasound guidance, and balloon angioplasty was performed for hemodynamically significant (>50%) stenosis. Technical and clinical success and complications were evaluated. Patency following percutaneous intervention was estimated with the Kaplan-Meier method. Technical success was achieved in 87.5% (seven of eight patients). Clinical success of normal hemodialysis (fistula maturation) occurred in 87.5% (seven of eight patients). One minor complication (regional hematoma) occurred in one patient. Mean primary patency at 6, 12, and 18 months was 75%, 56.2%, and 37.5%, respectively. Additional angioplasty (n=3) resulted in mean secondary patency at 12 and 18 months of 87.5% and 87.5% of the patients, respectively. In conclusion, percutaneous intervention with the transarterial approach can be a useful method for salvage of nonmaturing native fistulas when the transvenous approach fails.
Paudel, Kalyan; Hoffer, Eric K.
2015-01-01
Intrahepatic shunts between the portal and systemic venous systems with associated aneurysms are extremely rare. A middle aged woman presented with hepatic encephalopathy and was found to have two intrahepatic portosystemic venous shunts with associated aneurysms. Diagnosis was made by duplex ultrasound and was confirmed with contrast enhanced MRI. Treatment was performed percutaneously with an Amplatzer vascular plug. PMID:26257785
Pregnancies following ultrasound-guided drainage of tubo-ovarian abscess.
Gjelland, Knut; Granberg, Seth; Kiserud, Torvid; Wentzel-Larsen, Tore; Ekerhovd, Erling
2012-07-01
To study fertility among women treated by means of ultrasound-guided drainage and antibiotics for tubo-ovarian abscess (TOA). Retrospective cohort study. A tertiary referral center. One hundred women of reproductive age treated for TOA between June 1986 and July 2003. Transvaginal ultrasound-guided drainage of TOA was performed in all patients. The procedure was repeated if a substantial amount of pus was seen using ultrasonography 2-5 days after the initial aspiration, and repeated later if necessary. Frequency of naturally conceived pregnancies. Twenty of 38 (52.6%; 95% CI 36.5-68.9%) women who intended to have a child achieved pregnancy naturally and became mothers. In addition, 7 (50%) of 14 women who were not on birth control on a regular basis became pregnant. No ectopic pregnancies were registered. Ultrasound-guided drainage of TOA in combination with antibiotics seems to preserve fertility in approximately half of the patients. Copyright © 2012 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.
Gasparre, Giuseppe; Fusaro, Isabella; Galletti, Stefano; Volini, Silvia; Benedetti, Maria Grazia
2012-05-01
The aim of this study was to evaluate whether the association of exercises for the shoulder with ultrasound-guided injection into the bursa significantly improves the treatment outcome in adhesive bursitis. Two groups of 35 patients, one treated with ultrasound-guided injection (UGI) and the other one with ultrasound-guided injection and home exercise program (UGI-exercise) for 1 month, were assessed for pain and shoulder function before treatment, 1 and 3 months post-treatment. Fourteen patients in UGI group and 23 patients in the UGI-exercises group were completely free of pain after 1 month (p = 0.031). At 3 months' follow-up, patients in the UGI-exercise group showed a significant improvement with respect to the other group (p = 0.005). No differences were found in function assessment. The UGI combined with shoulder exercises in the treatment of subacromial adhesive bursitis is effective to ensure a more frequent complete pain relief in the medium term.
[Non-biological 3D printed simulator for training in percutaneous nephro- lithotripsy].
Alyaev, Yu G; Sirota, E S; Bezrukov, E A; Ali, S Kh; Bukatov, M D; Letunovskiy, A V; Byadretdinov, I Sh
2018-03-01
To develop a non-biological 3D printed simulator for training and preoperative planning in percutaneous nephrolithotripsy (PCNL), which allows doctors to master and perform all stages of the operation under ultrasound and fluoroscopy guidance. The 3D model was constructed using multislice spiral computed tomography (MSCT) images of a patient with staghorn urolithiasis. The MSCT data were processed and used to print the model. The simulator consisted of two parts: a non-biological 3D printed soft model of a kidney with reproduced intra-renal vascular and collecting systems and a printed 3D model of a human body. Using this 3D printed simulator, PCNL was performed in the interventional radiology operating room under ultrasound and fluoroscopy guidance. The designed 3D printed model of the kidney completely reproduces the individual features of the intra-renal structures of the particular patient. During the training, all the main stages of PCNL were performed successfully: the puncture, dilation of the nephrostomy tract, endoscopic examination, intra-renal lithotripsy. Our proprietary 3D-printed simulator is a promising development in the field of endourologic training and preoperative planning in the treatment of complicated forms of urolithiasis.