Khan, Farrah; Anker, Christopher J; Garrison, Garth; Kinsey, C Matthew
2015-01-01
Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is an established technique for the diagnosis of thoracic malignancies. Non-ultrasound-guided transbronchial needle injection has been used previously to deliver chemotherapeutic agents. To use endobronchial ultrasound-guided transbronchial needle injection (EBUS-TBNI) to achieve local control of recurrent early-stage lung cancer. A 63-year-old man presented with recurrent early stage non-small cell lung carcinoma after chemotherapy and external beam radiation. We used EBUS-TBNI to deliver cisplatin into the tumor located outside the airway. This procedure was performed on three separate occasions without complication. EBUS-TBNI resulted in resolution of fluorodeoxyglucose avidity, measured by positron emission tomography-computed tomography, in the region at 4 weeks. However, at 5 months, there was evidence of distal recurrence. This is the first description of EBUS-TBNI to treat local recurrence of lung cancer and one of the first reports of the use of EBUS for intratumoral therapy. Additional research is warranted to determine the clinical usefulness and safety of this therapeutic approach.
Parikh, Mihir S; Seeley, Eric; Nguyen-Tran, Evelyn; Krishna, Ganesh
2017-10-01
Surgical treatment with lung resection has traditionally been the treatment of choice for pulmonary cavities containing aspergillomas that cause hemoptysis. Endobronchial ultrasound (EBUS) is a minimally invasive bronchoscopic technique that is commonly used for transbronchial needle aspiration of hilar and mediastinal lymph nodes as well as centrally located parenchymal lesions. Here, we describe a case of a 71-year-old woman who was found to have a cavitary lesion in the lung containing aspergillomas. Under direct ultrasound visualization with EBUS, liposomal amphotericin B was injected into the aspergillomas. These aspergillomas regressed after treatment. To our knowledge, this is the first reported treatment of aspergilloma with EBUS-guided transbronchial needle injection of liposomal amphotericin B.
Madan, Karan; Mittal, Saurabh; Hadda, Vijay; Jain, Deepali; Mohan, Anant; Guleria, Randeep
2016-01-01
Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a minimally invasive and safe technique for a sampling of mediastinal lesions. Indications for EBUS-TBNA have gradually expanded since its introduction. The usual approach to cytological sampling of the thyroid gland is percutaneous ultrasound-guided fine needle aspiration (US-FNA) performed under local anesthesia. US-FNA may be risky or not feasible in intrathoracic/substernal thyroid location. Feasibility of aspirating thyroid lesions with EBUS-TBNA has been occasionally reported. We report two patients wherein EBUS-TBNA was utilized for thyroid lesion aspiration and definitive diagnosis. We highlight the utility and safety of EBUS-TBNA in the evaluation of intrathoracic thyroid lesions wherein image-guided percutaneous aspiration may be risky/sometimes impossible to perform. A systematic review of literature has also been performed summarizing and discussing the issues pertaining to EBUS-TBNA of the thyroid gland. PMID:27891005
Madan, Karan; Tiwari, Pavan; Arava, Sudheer; Hadda, Vijay; Mohan, Anant; Guleria, Randeep
2017-01-01
Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a minimally invasive and efficacious diagnostic modality for lung cancer staging and evaluation of undiagnosed mediastinal lymphadenopathy. Procedure-related complications are uncommon. We herein report an infrequently described phenomenon following EBUS-TBNA in which two patients developed nodular granulation tissue at the tracheobronchial puncture site. On systematic review, we found description of such phenomena by terminologies such as endobronchial inflammatory polyp, granuloma, and endobronchial mass. The endobronchial inflammatory polyp has been one of the most commonly used terminologies for these; but in most cases, the classical features of an inflammatory polyp are lacking. We propose the term, tracheobronchial puncture-site nodular reaction (TPNR) with further classification into granulomatous and nongranulomatous subtypes, for standardized reporting of such reactions following transbronchial needle aspiration procedures. Knowledge of this entity and standardized nomenclature shall help in better characterization of the outcomes and risk factors for the occurrence of these reactions.
Training and certification in endobronchial ultrasound-guided transbronchial needle aspiration
Konge, Lars; Nayahangan, Leizl Joy; Clementsen, Paul Frost
2017-01-01
Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) plays a key role in the staging of lung cancer, which is crucial for allocation to surgical treatment. EBUS-TBNA is a complicated procedure and simulation-based training is helpful in the first part of the long learning curve prior to performing the procedure on actual patients. New trainees should follow a structured training programme consisting of training on simulators to proficiency as assessed with a validated test followed by supervised practice on patients. The simulation-based training is superior to the traditional apprenticeship model and is recommended in the newest guidelines. EBUS-TBNA and oesophageal ultrasound-guided fine needle aspiration (EUS-FNA or EUS-B-FNA) are complementary to each other and the combined techniques are superior to either technique alone. It is logical to learn and to perform the two techniques in combination, however, for lung cancer staging solely EBUS-TBNA simulators exist, but hopefully in the future simulation-based training in EUS will be possible. PMID:28840013
Navani, Neal; Nankivell, Matthew; Lawrence, David R; Lock, Sara; Makker, Himender; Baldwin, David R; Stephens, Richard J; Parmar, Mahesh K; Spiro, Stephen G; Morris, Stephen; Janes, Sam M
2015-01-01
Summary Background The diagnosis and staging of lung cancer is an important process that identifies treatment options and guides disease prognosis. We aimed to assess endobronchial ultrasound-guided transbronchial needle aspiration as an initial investigation technique for patients with suspected lung cancer. Methods In this open-label, multicentre, pragmatic, randomised controlled trial, we recruited patients who had undergone a CT scan and had suspected stage I to IIIA lung cancer, from six UK centres and randomly assigned them to either endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) or conventional diagnosis and staging (CDS), for further investigation and staging. If a target node could not be accessed by EBUS-TBNA, then endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) was allowed as an alternative procedure. Randomisation was stratified according to the presence of mediastinal lymph nodes measuring 1 cm or more in the short axis and by recruiting centre. We used a telephone randomisation method with permuted blocks of four generated by a computer. Because of the nature of the intervention, masking of participants and consenting investigators was not possible. The primary endpoint was the time-to-treatment decision after completion of the diagnostic and staging investigations and analysis was by intention-to-diagnose. This trial is registered with ClinicalTrials.gov, number NCT00652769. Findings Between June 10, 2008, and July 4, 2011, we randomly allocated 133 patients to treatment: 66 to EBUS-TBNA and 67 to CDS (one later withdrew consent). Two patients from the EBUS-TBNA group underwent EUS-FNA. The median time to treatment decision was shorter with EBUS-TBNA (14 days; 95% CI 14–15) than with CDS (29 days; 23–35) resulting in a hazard ratio of 1·98, (1·39–2·82, p<0·0001). One patient in each group had a pneumothorax from a CT-guided biopsy sample; the patient from the CDS group needed intercostal drainage and was admitted to hospital. Interpretation Transbronchial needle aspiration guided by endobronchial ultrasound should be considered as the initial investigation for patients with suspected lung cancer, because it reduces the time to treatment decision compared with conventional diagnosis and staging techniques. Funding UK Medical Research Council. PMID:25660225
Huang, Chun-Ta; Chen, Chung-Yu; Ho, Chao-Chi; Yu, Chong-Jen
2011-07-01
The introduction of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) brought about significant advancement in the field of bronchoscopy. The major indications for EBUS-TBNA are lung cancer staging and diagnosis of mediastinal lymphadenopathy. This procedure is minimally invasive and cost saving, and no complications have been described in large-scale studies. In this report, we present a case of empyema, lung abscess, and mediastinal abscess that developed in a patient undergoing EBUS-TBNA; the patient subsequently recovered uneventfully after aggressive surgical debridement and antimicrobial therapy. Copyright © 2010 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.
Harris, Kassem; Modi, Kush; Kumar, Abhishek; Dhillon, Samjot Singh
2015-01-01
Convex probe endobronchial ultrasound (CP-EBUS) was originally introduced as a diagnostic and staging tool for lung cancer and subsequently utilized for diagnosis of other malignant and benign mediastinal diseases such as melanoma, lymphoma, and sarcoidosis. More recently, CP-EBUS has been successfully used for the visualization and diagnosis of pulmonary emboli and other vascular lesions including primary and metastatic pulmonary artery (PA) tumors. In this review, we will underline the role of EBUS-guided transbronchial needle aspiration (EBUS-TBNA) for the diagnosis of pulmonary arterial tumors such as sarcomas and tumor emboli. We will concisely discuss the clinical applications of EBUS-TBNA and the types of pulmonary arterial tumors and their different diagnostic modalities. We searched the Cochrane Library and PubMed from 2004 to 2014 to provide the most comprehensive review. Only 10 cases of EBUS-TBNA for intravascular lesions were identified in the literature. Although many cases of EBUS and EUS-guided transvascular tumor biopsies were described in the literature, there were no reported cases of endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) for intravascular tumor biopsies. Except for one paper, all cases were published as case reports.
Endobronchial Ultrasound-guided Transbronchial Needle Aspiration Using 19-G Needle for Sarcoidosis.
Balwan, Akshu
2018-05-16
Flexible bronchoscopy with endobronchial ultrasound (EBUS)-guided transbronchial needle aspiration (TBNA) is increasingly being used to obtain pathology specimens for diagnosis of sarcoidosis. There is wide variation in reported diagnostic yield in literature. New TBNA needles are available in the market but data are lacking about their diagnostic yield especially for sarcoidosis. This study reports the diagnostic yield of bronchoscopy with EBUS-TBNA using ViziShot FLEX 19-G needle in a series of patients with suspected sarcoidosis. This is a retrospective chart review for diagnostic yield of the 19-G EBUS-TBNA needle for suspected sarcoidosis. Eighty-six EBUS bronchoscopies were performed, 15 were done with clinical suspicion of sarcoidosis. The 19-G needle was used for all cases of suspected sarcoidosis. The procedure was diagnostic of sarcoidosis in 14 (93.3%) patients by TBNA with 1 nondiagnostic bronchoscopy. Procedural diagnostic yield was 93.3%. Eighty-five percent (28/33) of sampled lymph nodes were positive for noncaseating granulomas. The yield of transbronchial lung biopsy (TBLB) and endobronchial lung biopsy was 38% (5/13) and 43% (6/14), respectively. TBLB and endobronchial lung biopsy did not add to the diagnostic yield of the procedure. No significant adverse events were noted. This series reports a higher diagnostic yield than most other published studies and opens platform for direct comparison of each available needle. It also adds to the safety data for this larger needle. In addition, it raises doubt into utility of TBLB for diagnosis of sarcoidosis, which can increase the procedural complications.
Endobronchial ultrasound-guided lymph node biopsy with transbronchial needle forceps: a pilot study.
Herth, F J F; Schuler, H; Gompelmann, D; Kahn, N; Gasparini, S; Ernst, A; Schuhmann, M; Eberhardt, R
2012-02-01
One limitation of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is the size of the available needles, frequently yielding only cells for cytological examination. The aim of this pilot study was to evaluate the efficacy and safety of newly developed needle forceps to obtain tissue for the histological diagnosis of enlarged mediastinal lymph nodes. Patients with enlarged, positron emission tomography (PET)-positive lymph nodes were included. The transbronchial needle forceps (TBNF), a sampling instrument combining the characteristics of a needle (bevelled tip for penetrating through the bronchial wall) with forceps (two serrated jaws for grasping tissue) was used through the working channel of the EBUS-TBNA scope. Efficacy and safety was assessed. 50 patients (36 males and 14 females; mean age 51 yrs) with enlarged or PET-positive lymph nodes were included in this pilot study. In 48 (96%) patients penetration of the bronchial wall was possible and in 45 patients tissue for histological diagnosis was obtained. In three patients TBNF provided inadequate material. For patients in whom the material was adequate for a histological examination, a specific diagnosis was established in 43 (86%) out of 50 patients (nonsmall cell lung cancer: n=24; small cell lung cancer: n=7; sarcoidosis: n=4; Hodgkin's lymphoma: n=4; tuberculosis: n=2; and non-Hodgkin's lymphoma: n=2).No clinically significant procedure-related complications were encountered. This study demonstrated that EBUS-TBNF is a safe procedure and provides diagnostic histological specimens of mediastinal lymph nodes.
Endobronchial Ultrasound-guided Transbronchial Needle Aspiration With a 19-G Needle Device.
Tremblay, Alain; McFadden, Seamus; Bonifazi, Martina; Luzzi, Valentina; Kemp, Samuel V; Gasparini, Stefano; Chee, Alex; MacEachern, Paul; Dumoulin, Elaine; A Hergott, Christopher; Shah, Pallav L
2018-05-16
Endobronchial ultrasound (EBUS)-guided transbronchial needle aspiration is a well-established first-line minimally invasive modality for mediastinal lymph node sampling. Although results are excellent overall, the technique underperforms in certain situations. We aimed to describe our results using a new 19-G EBUS-guided transbronchial needle aspiration device to determine safety and feasibility of this approach. We completed a retrospective chart review of all cases performed to the time of data analysis at each of 3 study sites. A total of 165 procedures were performed with a total of 297 individual lymph nodes or lesions sampled with the 19-G device by 10 bronchoscopists. Relatively large targets were selected for sampling with the device (mean lymph node size: 20.4 mm; lung lesions: 33.5 mm). A specific diagnosis was obtained in 77.3% of cases with an additional 13.6% of cases with benign lymphocytes, for a procedural adequacy rate of 90.9%. Procedure sample adequacy was 88.6% in suspected malignant cases, 91.0% in suspected sarcoidosis/lymphadenopathy cases, and 85.7% of cases with suspected lymphoma. On a per-node basis, a specific diagnosis was noted in 191/280 (68.2%) of samples, with an additional 61 showing benign lymphocytes for a per-node sample adequacy rate of 90%. One case (0.6%) of intraprocedure bleeding was noted. A new flexible 19-G EBUS needle was successfully and safely applied in a large patient cohort for sampling of lung and enlarged mediastinal lesions with high diagnostic rates across clinical indications.
Leong, Steven C; Marshall, Henry M; Bint, Michael; Yang, Ian A; Bowman, Rayleen V; Fong, Kwun M
2013-10-01
Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a minimally invasive technique that allows lung cancer nodal staging and biopsy of parabronchial and paratracheal tissue. Its simplicity, high diagnostic yield, ability to diagnose both benign and malignant conditions, and exceedingly low complication rate has resulted in rapid widespread adoption by surgeons and physicians. EBUS-TBNA-related complications, however, do occur and need to be considered when assessing the risk-benefit profile of performing the procedure, and if the patient represents with unexpected symptoms after the procedure. We describe a 64-year-old woman who presented with a mediastinal abscess 5 days after EBUS-TBNA. This case demonstrates the importance of considering EBUS-TBNA-related complications to guide relevant imaging decisions and antibiotic choices. We review the published literature regarding infective complications of EBUS-TBNA and propose possible pathophysiologies. These complications are likely to increase in frequency as the technique is more widely adopted.
Aziz, Fahad
2012-09-01
Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) offers a minimally invasive alternative to mediastinoscopy with additional access to the hilar nodes, a better safety profile, and it removes the costs and hazards of theatre time and general anesthesia with comparable sensitivity, although the negative predictive value of mediastinoscopy (and sample size) is greater. EBUS- TBNA also obtains larger samples than conventional TBNA, has superior performance and theoretically is safer, allowing real-time sampling under direct vision. It can also have predictive value both in sonographic appearance of the nodes and histological characteristics. EBUS-TBNA is therefore indicated for NSCLC staging, diagnosis of lung cancer when there is no endobronchial lesion, and diagnosis of both benign (especially tuberculosis and sarcoidosis) and malignant mediastinal lesions. The procedure is different than for flexible bronchoscopy, takes longer, and requires more training. EBUS-TBNA is more expensive than conventional TBNA but can save costs by reducing the number of more costly mediastinoscopies. In the future, endobronchial ultrasound may have applications in airways disease and pulmonary vascular disease.
Figueiredo, Viviane Rossi; Cardoso, Paulo Francisco Guerreiro; Jacomelli, Márcia; Demarzo, Sérgio Eduardo; Palomino, Addy Lidvina Mejia; Rodrigues, Ascédio José; Terra, Ricardo Mingarini; Pego-Fernandes, Paulo Manoel; Carvalho, Carlos Roberto Ribeiro
2015-01-01
Objective: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a minimally invasive, safe and accurate method for collecting samples from mediastinal and hilar lymph nodes. This study focused on the initial results obtained with EBUS-TBNA for lung cancer and lymph node staging at three teaching hospitals in Brazil. Methods: This was a retrospective analysis of patients diagnosed with lung cancer and submitted to EBUS-TBNA for mediastinal lymph node staging. The EBUS-TBNA procedures, which involved the use of an EBUS scope, an ultrasound processor, and a compatible, disposable 22 G needle, were performed while the patients were under general anesthesia. Results: Between January of 2011 and January of 2014, 149 patients underwent EBUS-TBNA for lymph node staging. The mean age was 66 ± 12 years, and 58% were male. A total of 407 lymph nodes were sampled by EBUS-TBNA. The most common types of lung neoplasm were adenocarcinoma (in 67%) and squamous cell carcinoma (in 24%). For lung cancer staging, EBUS-TBNA was found to have a sensitivity of 96%, a specificity of 100%, and a negative predictive value of 85%. Conclusions: We found EBUS-TBNA to be a safe and accurate method for lymph node staging in lung cancer patients. PMID:25750671
Figueiredo, Viviane Rossi; Cardoso, Paulo Francisco Guerreiro; Jacomelli, Márcia; Demarzo, Sérgio Eduardo; Palomino, Addy Lidvina Mejia; Rodrigues, Ascédio José; Terra, Ricardo Mingarini; Pego-Fernandes, Paulo Manoel; Carvalho, Carlos Roberto Ribeiro
2015-01-01
Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a minimally invasive, safe and accurate method for collecting samples from mediastinal and hilar lymph nodes. This study focused on the initial results obtained with EBUS-TBNA for lung cancer and lymph node staging at three teaching hospitals in Brazil. This was a retrospective analysis of patients diagnosed with lung cancer and submitted to EBUS-TBNA for mediastinal lymph node staging. The EBUS-TBNA procedures, which involved the use of an EBUS scope, an ultrasound processor, and a compatible, disposable 22 G needle, were performed while the patients were under general anesthesia. Between January of 2011 and January of 2014, 149 patients underwent EBUS-TBNA for lymph node staging. The mean age was 66 ± 12 years, and 58% were male. A total of 407 lymph nodes were sampled by EBUS-TBNA. The most common types of lung neoplasm were adenocarcinoma (in 67%) and squamous cell carcinoma (in 24%). For lung cancer staging, EBUS-TBNA was found to have a sensitivity of 96%, a specificity of 100%, and a negative predictive value of 85%. We found EBUS-TBNA to be a safe and accurate method for lymph node staging in lung cancer patients.
Akulian, Jason; Lechtzin, Noah; Yasin, Faiza; Kamdar, Biren; Ernst, Armin; Ost, David E.; Ray, Cynthia; Greenhill, Sarah R.; Jimenez, Carlos A.; Filner, Joshua; Feller-Kopman, David
2013-01-01
Background: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a minimally invasive procedure originally performed using a 22-gauge (22G) needle. A recently introduced 21-gauge (21G) needle may improve the diagnostic yield and sample adequacy of EBUS-TBNA, but prior smaller studies have shown conflicting results. To our knowledge, this is the largest study undertaken to date to determine whether the 21G needle adds diagnostic benefit. Methods: We retrospectively evaluated the results of 1,299 patients from the American College of Chest Physicians Quality Improvement Registry, Education, and Evaluation (AQuIRE) Diagnostic Registry who underwent EBUS-TBNA between February 2009 and September 2010 at six centers throughout the United States. Data collection included patient demographics, sample adequacy, and diagnostic yield. Analysis consisted of univariate and multivariate hierarchical logistic regression comparing diagnostic yield and sample adequacy of EBUS-TBNA specimens by needle gauge. Results: A total of 1,235 patients met inclusion criteria. Sample adequacy was obtained in 94.9% of the 22G needle group and in 94.6% of the 21G needle group (P = .81). A diagnosis was made in 51.4% of the 22G and 51.3% of the 21G groups (P = .98). Multivariate hierarchical logistic regression showed no statistical difference in sample adequacy or diagnostic yield between the two groups. The presence of rapid onsite cytologic evaluation was associated with significantly fewer needle passes per procedure when using the 21G needle (P < .001). Conclusions: There is no difference in specimen adequacy or diagnostic yield between the 21G and 22G needle groups. EBUS-TBNA in conjunction with rapid onsite cytologic evaluation and a 21G needle is associated with fewer needle passes compared with a 22G needle. PMID:23632441
Yokoyama, Yujiro; Nakagomi, Takahiro; Shikata, Daichi; Higuchi, Rumi; Oyama, Toshio; Goto, Taichiro
2017-07-14
Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a useful and less invasive procedure for the definitive diagnosis of mediastinal and hilar lymph nodes. However, infectious complications can occur after EBUS-TBNA, although they are extremely rare. A 66-year-old man with necrotic and swollen lower paratracheal lymph nodes underwent EBUS-TBNA. A mediastinal abscess developed 9 days post-procedure. Surgical drainage and debridement of the abscess were performed along with lymph node biopsy followed by daily washing of the thoracic cavity. Surgical treatment was effective, leading to remission of the abscess. Biopsy revealed that the tumor was squamous cell carcinoma with no radiologically detected cancer elsewhere in the body. Mediastinal lung cancer was thus confirmed. Subsequent chemoradiotherapy led to the remission of the tumor. Mediastinitis after EBUS-TBNA is rare but should be considered, particularly if the target lymph nodes are necrotic. Mediastinitis can lead to serious and rapid deterioration of the patient's condition, for which surgical intervention is the treatment of choice.
Tian, Lei; Krimsky, William S; Wu, Qingchen; Sun, Jiayuan
2017-07-01
Mediastinal abscess is a fatal condition, treatment of mediastinal abscess is with antibiotics and sometimes surgery for debridement and drainage. Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a safe assessment and candidate treatment method of mediastinal lesions. This study aimed to HYPERLINK "javascript:void(0);" discuss risks and benefits in treatment of mediastinal abscess by EBUS-TBNA. We noticed a 56-year-old man with developed bilateral pneumonia and sepsis after puncture of mediastinal abscess by EBUS-TBNA. The patient was successfully treated with a combination of systemic anti-infection treatment and intracavitary administration of antibiotics, antifungal and repeated drainage and lavage via EBUS-TBNA, in 1 year follow-up without recurrence. This study indicated infection spread risk of mediastinal abscess after EBUS-TBNA, and mediastinal abscess was successfully cured by combination of systemic anti-infection and local intervention through EBUS-TBNA. EBUS-TBNA is a potential effective minimally invasive treatment for mediastinal abscess, and it is necessary to be aware of clinical complications after puncture of mediastinal infectious lesions by EBUS-TBNA. © 2015 John Wiley & Sons Ltd.
Jiang, Jun-Hong; Turner, J Francis; Huang, Jian-An
2015-12-01
TBNA through the flexible bronchoscope is a 37-year-old technology that utilizes a TBNA needle to puncture the bronchial wall and obtain specimens of peribronchial and mediastinal lesions through the flexible bronchoscope for the diagnosis of benign and malignant diseases in the mediastinum and lung. Since 2002, the Olympus Company developed the first generation ultrasound equipment for use in the airway, initially utilizing an ultrasound probe introduced through the working channel followed by incoroporation of a fixed linear ultrasound array at the distal tip of the bronchoscope. This new bronchoscope equipped with a convex type ultrasound probe on the tip was subsequently introduced into clinical practice. The convex probe (CP)-EBUS allows real-time endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) of mediastinal and hilar lymph nodes. EBUS-TBNA is a minimally invasive procedure performed under local anesthesia that has been shown to have a high sensitivity and diagnostic yield for lymph node staging of lung cancer. In 10 years of EBUS development, the Olympus Company developed the second generation EBUS bronchoscope (BF-UC260FW) with the ultrasound image processor (EU-M1), and in 2013 introduced a new ultrasound image processor (EU-M2) into clinical practice. FUJI company has also developed a curvilinear array endobronchial ultrasound bronchoscope (EB-530 US) that makes it easier for the operator to master the operation of the ultrasonic bronchoscope. Also, the new thin convex probe endobronchial ultrasound bronchoscope (TCP-EBUS) is able to visualize one to three bifurcations distal to the current CP-EBUS. The emergence of EBUS-TBNA has also been accompanied by innovation in EBUS instruments. EBUS elastography is, then, a new technique for describing the compliance of structures during EBUS, which may be of use in the determination of metastasis to the mediastinal and hilar lymph nodes. This article describes these new EBUS techniques and reviews the relevant literature.
Pulmonary Abscess as a Complication of Transbronchial Lung Cryobiopsy.
Skalski, Joseph H; Kern, Ryan M; Midthun, David E; Edell, Eric S; Maldonado, Fabien
2016-01-01
We present the case of a 49-year-old man who developed pulmonary abscess as a complication of transbronchial lung cryobiopsy. He had been receiving prednisone therapy, but otherwise had no specific risk factors for lung abscess. Cryobiopsy is a novel technique for obtaining peripheral lung parenchymal tissue for the evaluation of diffuse parenchymal lung diseases. Cryobiopsy is being increasingly proposed as an alternative to surgical lung biopsy or conventional bronchoscopic transbronchial forceps biopsy, but the safety profile of the procedure has not been fully appreciated. Pulmonary abscess has been rarely reported as a complication of other bronchoscopic procedures such as endobronchial ultrasound-guided needle biopsy, however, to our knowledge this is the first reported case of pulmonary abscess complicating peripheral lung cryobiopsy.
Yarmus, Lonny B; Akulian, Jason; Lechtzin, Noah; Yasin, Faiza; Kamdar, Biren; Ernst, Armin; Ost, David E; Ray, Cynthia; Greenhill, Sarah R; Jimenez, Carlos A; Filner, Joshua; Feller-Kopman, David
2013-04-01
Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a minimally invasive procedure originally performed using a 22-gauge (22G) needle. A recently introduced 21-gauge (21G) needle may improve the diagnostic yield and sample adequacy of EBUS-TBNA, but prior smaller studies have shown conflicting results. To our knowledge, this is the largest study undertaken to date to determine whether the 21G needle adds diagnostic benefit. We retrospectively evaluated the results of 1,299 patients from the American College of Chest Physicians Quality Improvement Registry, Education, and Evaluation (AQuIRE) Diagnostic Registry who underwent EBUS-TBNA between February 2009 and September 2010 at six centers throughout the United States. Data collection included patient demographics, sample adequacy, and diagnostic yield. Analysis consisted of univariate and multivariate hierarchical logistic regression comparing diagnostic yield and sample adequacy of EBUS-TBNA specimens by needle gauge. A total of 1,235 patients met inclusion criteria. Sample adequacy was obtained in 94.9% of the 22G needle group and in 94.6% of the 21G needle group (P = .81). A diagnosis was made in 51.4% of the 22G and 51.3% of the 21G groups (P = .98). Multivariate hierarchical logistic regression showed no statistical difference in sample adequacy or diagnostic yield between the two groups. The presence of rapid onsite cytologic evaluation was associated with significantly fewer needle passes per procedure when using the 21G needle (P < .001). There is no difference in specimen adequacy or diagnostic yield between the 21G and 22G needle groups. EBUS-TBNA in conjunction with rapid onsite cytologic evaluation and a 21G needle is associated with fewer needle passes compared with a 22G needle.
Bramley, Kyle; Pisani, Margaret A; Murphy, Terrence E; Araujo, Katy L; Homer, Robert J; Puchalski, Jonathan T
2016-05-01
Endobronchial ultrasound (EBUS)-guided transbronchial needle aspiration (TBNA) is important in the evaluation of thoracic lymphadenopathy. Reliably providing excellent diagnostic yield for malignancy, its diagnosis of sarcoidosis is inconsistent. Furthermore, TBNA may not suffice when larger "core biopsy" samples of malignant tissue are required. The primary objective of this study was to determine if the sequential use of TBNA and a novel technique called cautery-assisted transbronchial forceps biopsy (ca-TBFB) was safe. Secondary outcomes included sensitivity and successful acquisition of tissue. The study prospectively enrolled 50 unselected patients undergoing convex-probe EBUS. All lymph nodes exceeding 1 cm were sequentially biopsied under EBUS guidance using TBNA and ca-TBFB. Safety and sensitivity were assessed at the nodal level for 111 nodes. Results of each technique were also reported for each patient. There were no significant adverse events. In nodes determined to be malignant, TBNA provided higher sensitivity (100%) than ca-TBFB (78%). However, among nodes with granulomatous inflammation, ca-TBFB exhibited higher sensitivity (90%) than TBNA (33%). On the one hand, for analysis based on patients rather than nodes, 6 of the 31 patients with malignancy would have been missed or understaged if the diagnosis were based on samples obtained by ca-TBFB. On the other hand, 3 of 8 patients with sarcoidosis would have been missed if analysis were based only on TBNA samples. In some patients, only ca-TBFB acquired sufficient tissue for the core samples needed in clinical trials of malignancy. The sequential use of TBNA and ca-TBFB appears to be safe. The larger samples obtained from ca-TBFB increased its sensitivity to detect granulomatous disease and provided adequate specimens for clinical trials of malignancy when specimens from needle biopsies were insufficient. For thoracic surgeons and advanced bronchoscopists, we advocate ca-TBFB as an alternative to TBNA in select clinical scenarios. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Schacht, M J; Toustrup, C B; Madsen, L B; Martiny, M S; Larsen, B B; Simonsen, J T
2016-10-01
Rapid on-site evaluation (ROSE) of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) followed by a subsequent preliminary adequacy assessment and a preliminary diagnosis, was performed at Aarhus University Hospital by biomedical scientists (BMS). The aim of this study was to evaluate the BMS accuracy of ROSE adequacy assessment, the preliminary adequacy assessment and the preliminary diagnosis as compared with the cytopathologist-rendered final adequacy assessment and final diagnosis. The BMS-rendered assessments for 717 sites from 319 consecutive patients over a 4-month period were compared with the cytopathologist-rendered assessments. Comparisons of adequacy and preliminary diagnoses were based on inter-observer Cohen's Kappa coefficient with a 95% confidence interval (CI). Strong correlations between ROSE and final adequacy assessments [Kappa coefficient of 0.90 (CI: 0.85-0.96)] and between the preliminary and final adequacy assessments [Kappa coefficient of 0.93 (CI: 0.87-0.99)] were found. As for the correlation between the preliminary and final diagnoses, the Kappa coefficient was 0.99 (CI: 0.98-1). Both ROSE and preliminary adequacy assessments as well as preliminary diagnoses, all performed by BMS, were highly accurate when compared with the final assessment by the cytopathologist. © 2016 John Wiley & Sons Ltd.
Krenke, Rafal; Korczynski, Piotr; Gorska, Katarzyna; Chazan, Ryszarda
2014-03-01
The high diagnostic yield and favorable safety profile of endobronchial ultrasound-guided transbronchial forceps biopsy of the mediastinal lymph nodes have been recently demonstrated. We report an unusual technical problem during endobronchial ultrasound-guided transbronchial forceps biopsy that could be a prerequisite for severe complications. A rupture of the steering band precluded closure of the forceps jaws opened in the subcarinal lymph node. A solution to the problem is presented, together with other procedure-related complications reported in the literature. The report emphasizes that a dysfunction of the forceps steering band can result in severe complications when it occurs during transbronchial sampling of mediastinal lesions. Copyright © 2014 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Patel, Priya; Wada, Hironobu; Hu, Hsin-Pei; Hirohashi, Kentaro; Kato, Tatsuya; Ujiie, Hideki; Ahn, Jin Young; Lee, Daiyoon; Geddie, William; Yasufuku, Kazuhiro
2017-04-01
Endobronchial ultrasonography (EBUS)-guided transbronchial needle aspiration allows for sampling of mediastinal lymph nodes. The external diameter, rigidity, and angulation of the convex probe EBUS renders limited accessibility. This study compares the accessibility and transbronchial needle aspiration capability of the prototype thin convex probe EBUS against the convex probe EBUS in human ex vivo lungs rejected for transplant. The prototype thin convex probe EBUS (BF-Y0055; Olympus, Tokyo, Japan) with a thinner tip (5.9 mm), greater upward angle (170 degrees), and decreased forward oblique direction of view (20 degrees) was compared with the current convex probe EBUS (6.9-mm tip, 120 degrees, and 35 degrees, respectively). Accessibility and transbronchial needle aspiration capability was assessed in ex vivo human lungs declined for lung transplant. The distance of maximum reach and sustainable endoscopic limit were measured. Transbronchial needle aspiration capability was assessed using the prototype 25G aspiration needle in segmental lymph nodes. In all evaluated lungs (n = 5), the thin convex probe EBUS demonstrated greater reach and a higher success rate, averaging 22.1 mm greater maximum reach and 10.3 mm further endoscopic visibility range than convex probe EBUS, and could assess selectively almost all segmental bronchi (98% right, 91% left), demonstrating nearly twice the accessibility as the convex probe EBUS (48% right, 47% left). The prototype successfully enabled cytologic assessment of subsegmental lymph nodes with adequate quality using the dedicated 25G aspiration needle. Thin convex probe EBUS has greater accessibility to peripheral airways in human lungs and is capable of sampling segmental lymph nodes using the aspiration needle. That will allow for more precise assessment of N1 nodes and, possibly, intrapulmonary lesions normally inaccessible to the conventional convex probe EBUS. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Hu, Li-Xing; Chen, Ru-Xuan; Huang, Hui; Shao, Chi; Wang, Ping; Liu, Yong-Zhe; Xu, Zuo-Jun
2016-01-01
Background: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is an effective technique used to precisely detect enlarged mediastinal lymph nodes. The efficacy of EBUS-TBNA versus standard modalities for the diagnosis of sarcoidosis remains to be elucidated. In this meta-analysis, we compared the efficacies of these methods. Methods: We searched PubMed, Embase, The Cochrane Library, Wanfang, Cpvip, CNKI, and the bibliographies of the relevant references. We analyzed the data obtained with Revman 5.2 (Nordic Cochrane Center, Copenhagen, Denmark) and Stata 12.0 software (Stata Corporation, College Station, TX, USA). The Mantel-Haenszel method was used to calculate the pooled odds ratio (OR) and 95% confidence intervals (CIs). Results: Sixteen studies with a total of 1823 participants met the inclusion criteria, and data were extracted regarding the diagnostic yield of each approach. The ORs for EBUS-TBNA versus transbronchial lung biopsy (TBLB) for the diagnosis of sarcoidosis ranged from 0.26 to 126.58, and the pooled OR was 5.89 (95% CI, 2.20–15.79, P = 0.0004). These findings indicated that EBUS-TBNA provided a much higher diagnostic yield than TBLB. The pooled OR for EBUS-TBNA + TBLB + endobronchial biopsy (EBB) versus TBNA + TBLB + EBB was 1.54 (95% CI, 0.61–3.93, P = 0.36), implying that there was no significant difference between their diagnostic yields. However, clinical heterogeneity was reflected in the nature of the studies and in the operative variables. Conclusions: The results of this meta-analysis suggest that EBUS-TBNA + TBLB + EBB could be used for the diagnosis of sarcoidosis, if available. At medical centers without EBUS-TBNA, TBNA + TBLB + EBB could be used instead. PMID:27364799
Shah, Archan M.; Lei, Xiudong; Jimenez, Carlos A.; Morice, Rodolfo C.; Yarmus, Lonny; Filner, Joshua; Ray, Cynthia; Michaud, Gaetane; Greenhill, Sara R.; Sarkiss, Mona; Casal, Roberto; Rice, David; Ost, David E.
2013-01-01
Background: Few studies of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) have been large enough to identify risk factors for complications. The primary objective of this study was to quantify the incidence of and risk factors for complications in patients undergoing EBUS-TBNA. Methods: Data on prospectively enrolled patients undergoing EBUS-TBNA in the American College of Chest Physicians Quality Improvement Registry, Evaluation, and Education (AQuIRE) database were extracted and analyzed for the incidence, consequences, and predictors of complications. Results: We enrolled 1,317 patients at six hospitals. Complications occurred in 19 patients (1.44%; 95% CI, 0.87%-2.24%). Transbronchial lung biopsy (TBBx) was the only risk factor for complications, which occurred in 3.21% of patients who underwent the procedure and in 1.15% of those who did not (OR, 2.85; 95% CI, 1.07-7.59; P = .04). Pneumothorax occurred in seven patients (0.53%; 95% CI, 0.21%-1.09%). Escalations in level of care occurred in 14 patients (1.06%; 95% CI, 0.58%-1.78%); its risk factors were age > 70 years (OR, 4.06; 95% CI, 1.36-12.12; P = .012), inpatient status (OR, 4.93; 95% CI, 1.30-18.74; P = .019), and undergoing deep sedation or general anesthesia (OR, 4.68; 95% CI, 1.02-21.61; P = .048). TBBx was performed in only 12.6% of patients when rapid onsite cytologic evaluation (ROSE) was used and in 19.1% when it was not used (P = .006). Interhospital variation in TBBx use when ROSE was used was significant (P < .001). Conclusions: TBBx was the only risk factor for complications during EBUS-TBNA procedures. ROSE significantly reduced the use of TBBx. PMID:23117878
Norisue, Yasuhiro; Tokuda, Yasuharu; Juarez, Mayrol; Uchimido, Ryo; Fujitani, Shigeki; Stoeckel, David A
2017-02-07
Cumulative sum (CUSUM) analysis can be used to continuously monitor the performance of an individual or process and detect deviations from a preset or standard level of achievement. However, no previous study has evaluated the utility of CUSUM analysis in facilitating timely environmental assessment and interventions to improve performance of linear-probe endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA). The aim of this study was to evaluate the usefulness of combined CUSUM and chronological environmental analysis as a tool to improve the learning environment for EBUS-TBNA trainees. This study was an observational chart review. To determine if performance was acceptable, CUSUM analysis was used to track procedural outcomes of trainees in EBUS-TBNA. To investigate chronological changes in the learning environment, multivariate logistic regression analysis was used to compare several indices before and after time points when significant changes occurred in proficiency. Presence of an additional attending bronchoscopist was inversely associated with nonproficiency (odds ratio, 0.117; 95% confidence interval, 0-0.749; P = 0.019). Other factors, including presence of an on-site cytopathologist and dose of sedatives used, were not significantly associated with duration of nonproficiency. Combined CUSUM and chronological environmental analysis may be useful in hastening interventions that improve performance of EBUS-TBNA.
Fernández-Bussy, Sebastián; Labarca, Gonzalo; Canals, Sofia; Caviedes, Iván; Folch, Erik; Majid, Adnan
2015-01-01
OBJECTIVE: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a minimally invasive diagnostic test with a high diagnostic yield for suspicious central pulmonary lesions and for mediastinal lymph node staging. The main objective of this study was to describe the diagnostic yield of EBUS-TBNA for mediastinal lymph node staging in patients with suspected lung cancer. METHODS: Prospective study of patients undergoing EBUS-TBNA for diagnosis. Patients ≥ 18 years of age were recruited between July of 2010 and August of 2013. We recorded demographic variables, radiological characteristics provided by axial CT of the chest, location of the lesion in the mediastinum as per the International Association for the Study of Lung Cancer classification, and definitive diagnostic result (EBUS with a diagnostic biopsy or a definitive diagnostic method). RESULTS: Our analysis included 354 biopsies, from 145 patients. Of those 145 patients, 54.48% were male. The mean age was 63.75 years. The mean lymph node size was 15.03 mm, and 90 lymph nodes were smaller than 10.0 mm. The EBUS-TBNA method showed a sensitivity of 91.17%, a specificity of 100.0%, and a negative predictive value of 92.9%. The most common histological diagnosis was adenocarcinoma. CONCLUSIONS: EBUS-TBNA is a diagnostic tool that yields satisfactory results in the staging of neoplastic mediastinal lesions. PMID:26176519
Chen, Cheng; Mu, Chuan-Yong; Su, Mei-Qin; Mao, Jing-Yu; Zhu, Ye-Han; Huang, Jian-An
2017-01-01
Background: Due to absence of visible endobronchial target, the diagnostic yield of flexible bronchoscopy for peribronchial lesions has been unsatisfactory. Convex probe endobronchial ultrasound (CP-EBUS) has allowed for performing real-time transbronchial needle aspiration (TBNA) of enlarged hilar and mediastinal lymph nodes and therefore could also be used as a means of diagnosing proximal peribronchial lesions. Methods: We retrospectively analyzed the results related to 72 patients who underwent CP-EBUS for peribronchial lesions without endobronchial involvement and adjacent to three-grade bronchi based on chest computed tomography (CT) scan. We recorded the images during EBUS as well as the diagnostic results of TBNA and conventional-transbronchial lung biopsy/brush (C-TBLB/b), and final diagnoses were based on pathologic analysis and follow-up. Results: In all cases, the mass was able to be identified using EBUS in 97.2% patients (70/72) who were performed with EBUS-TBNA + C-TBLB/b. Sixty-six patients had a final diagnosis, 80.0% patients (56/70) had malignancies, and 14.3% patients (10/70) had benign disease. In malignancies, the diagnostic yield of C-TBLB/b was 57.1% (32/56) and in EBUS-TBNA was 85.7% (48/56), whereas pathologic diagnosis reached 94.6% when EBUS-TBNA was combined with C-TBLB/b. C-TBLB/b + EBUS-TBNA also exhibited stronger potency of histolytic diagnosis for malignancies than either EBUS-TBNA or C-TBLB/b alone. Furthermore, there are data supporting the value of EBUS-TBNA for the diagnosis of benign lung disease. Conclusion: The combined endoscopic approach with EBUS-TBNA and C-TBLB/b is an accurate and effective method for the evaluation of peribronchial lesions, with better results than using each technique alone. PMID:28051017
Huang, Haidong; Huang, Zhiang; Wang, Qin; Wang, Xinan; Dong, Yuchao; Zhang, Wei; Zarogoulidis, Paul; Man, Yan-Gao; Schmidt, Wolfgang Hohenforst; Bai, Chong
2017-01-01
Background and Objectives: Endobronchial ultrasound elastography is a new technique for describing the stiffness of tissue during endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA). The aims of this study were to investigate the diagnostic value of Endobronchial ultrasound (EBUS) elastography for distinguishing the difference between benign and malignant lymph nodes among mediastinal and hilar lymph node. Materials and Methods: From June 2015 to August 2015, 47 patients confirmed of mediastinal and hilar lymph node enlargement through examination of Computed tomography (CT) were enrolled, and a total of 78 lymph nodes were evaluated by endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA). EBUS-guided elastography of lymph nodes was performed prior to EBUS-TBNA. A convex probe EBUS was used with a new EBUS processor to assess elastographic patterns that were classified based on color distribution as follows: Type 1, predominantly non-blue (green, yellow and red); Type 2, part blue, part non-blue (green, yellow and red); Type 3, predominantly blue. Pathological determination of malignant or benign lymph nodes was used as the gold standard for this study. The elastographic patterns were compared with the final pathologic results from EBUS-TBNA. Results: On pathological evaluation of the lymph nodes, 45 were benign and 33 were malignant. The lymph nodes that were classified as Type 1 on endobronchial ultrasound elastography were benign in 26/27 (96.3%) and malignant in 1/27 (3.7%); for Type 2 lymph nodes, 15/20 (75.0%) were benign and 5/20 (25.0%) were malignant; Type 3 lymph nodes were benign in 4/31 (12.9%) and malignant in 27/31 (87.1%). In classifying Type 1 as 'benign' and Type 3 as 'malignant,' the sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy rates were 96.43%, 86.67%, 87.10%, 96.30%, 91.38%, respectively. Conclusion: EBUS elastography of mediastinal and hilar lymph nodes is a noninvasive technique that can be performed reliably and may be helpful in the prediction of benign and malignant lymph nodes among mediastinal and hilar lymph node during EBUS-TBNA.
Detection of an embolized central venous catheter fragment with endobronchial ultrasound.
Dhillon, Samjot Singh; Harris, Kassem; Alraiyes, Abdul H; Picone, Anthony L
2018-01-01
An 84-year-old woman underwent Convex-probe Endobronchial Ultrasound (CP-EBUS) for 18 F-fluorodeoxyglucose avid subcarinal lymphadenopathy on Positron Emission Tomogram (PET) scan. Endobronchial ultrasound-guided transbronchial needle aspiration of the subcarinal lymph node revealed squamous cell lung carcinoma. A small hyperechoic rounded density was noted inside the lumen of the azygous vein. Based on chest computed tomography findings and her clinical history, this was felt to be a broken fragment of a peripherally inserted central catheter, which was placed for intravenous antibiotics, a few months prior to this presentation. To the best of our knowledge, this is the first ever CP-EBUS description of a broken fragment of central venous catheter. © 2016 John Wiley & Sons Ltd.
Marchand, Clare
2017-01-01
Background Endobronchial ultrasound‐guided transbronchial needle aspiration (EBUS‐TBNA) diagnoses and stages mediastinal lymph node pathology. This retrospective study determined the relationship between EBUS‐TBNA utility and non‐small cell lung cancer (NSCLC) stage, lymph node size, and positron emission tomography (PET) standard uptake values (SUV), and the utility of neck ultrasound in bulky mediastinal disease. Methods Data of 284 consecutive patients who had undergone EBUS‐TBNA was collected. Two hundred patients had suspected NSCLC, with 148 confirmed NSCLC cases. The diagnostic utility of EBUS‐TBNA was determined according to NSCLC stage, EBUS lymph node size, PET SUV, use in distal metastases, and mutation testing. The utility of neck ultrasound for N3 disease was calculated in patients with bulky mediastinal disease. Results EBUS‐TBNA was well tolerated with 97% sensitivity in distant metastatic disease, avoiding the need for distal metastases biopsy in 81% of cases. It had equivalent diagnostic accuracy in all NSCLC stages and in lymph nodes <10 mm, <20 mm or >20 mm (sensitivity >92% in all cases), with no mutation testing failures. EBUS‐TBNA had 33% sensitivity in PET indolent (SUV < 4) nodes and 79% sensitivity in PET active nodes (SUV > 4). EBUS‐TBNA diagnosed 12 cases of lymphoma without flow cytometry. Conclusions The use of EBUS‐TBNA meant that distant metastatic biopsy was avoided in 81% of cases, performing well irrespective of cancer stage, node size, and facilitating mutation testing. Neck ultrasound failed to detect N3 disease in patients with bulky mediastinal disease. EBUS‐TBNA had a sensitivity of 33% for metastases in PET negative nodes, highlighting PET limitations. PMID:28436173
Asano, Fumihiro; Aoe, Motoi; Ohsaki, Yoshinobu; Okada, Yoshinori; Sasada, Shinji; Sato, Shigeki; Suzuki, Eiichi; Semba, Hiroshi; Fukuoka, Kazuya; Fujino, Shozo; Ohmori, Kazumitsu
2013-05-10
With the recent widespread use of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA), there have been occasional reports on complications associated with its use. Previous reviews on EBUS-TBNA have been limited to studies by skilled operators, thus the results may not always be applicable to recent clinical practice. To assess the safety of EBUS-TBNA for the staging and diagnosis of lung cancer in Japan, a nationwide survey on its current usage status and complications associated with its use was conducted by the Japan Society for Respiratory Endoscopy (JSRE). A questionnaire about EBUS-TBNA performed between January 2011 and June 2012 was mailed to 520 JSRE-accredited facilities. Responses were obtained from 455 facilities (87.5%). During the study period, EBUS-TBNA was performed in 7,345 cases in 210 facilities (46.2%) using a convex probe ultrasound bronchoscope, for 6,836 mediastinal and hilar lesions and 275 lung parenchymal lesions. Ninety complications occurred in 32 facilities. The complication rate was 1.23% (95% confidence interval, 0.97%-1.48%), with hemorrhage being the most frequent complication (50 cases, 0.68%). Infectious complications developed in 14 cases (0.19%) (Mediastinitis, 7; pneumonia, 4; pericarditis, 1; cyst infection, 1; and sepsis, 1). Pneumothorax developed in 2 cases (0.03%), one of which required tube drainage. Regarding the outcome of the cases with complications, prolonged hospitalization was observed in 14 cases, life-threatening conditions in 4, and death in 1 (severe cerebral infarction) (mortality rate, 0.01%). Breakage of the ultrasound bronchoscope occurred in 98 cases (1.33%) in 67 facilities (31.9%), and that of the puncture needle in 15 cases (0.20%) in 8 facilities (3.8%). Although the complication rate associated with EBUS-TBNA was found to be low, severe complications, including infectious complications, were observed, and the incidence of device breakage was high. Since the use of EBUS-TBNA is rapidly expanding in Japan, an educational program for its safe performance should be immediately established.
Wahidi, Momen M; Herth, Felix; Yasufuku, Kazuhiro; Shepherd, Ray Wesley; Yarmus, Lonny; Chawla, Mohit; Lamb, Carla; Casey, Kenneth R; Patel, Sheena; Silvestri, Gerard A; Feller-Kopman, David J
2016-03-01
Endobronchial ultrasound (EBUS) was introduced in the last decade, enabling real-time guidance of transbronchial needle aspiration (TBNA) of mediastinal and hilar structures and parabronchial lung masses. The many publications produced about EBUS-TBNA have led to a better understanding of the performance characteristics of this procedure. The goal of this document was to examine the current literature on the technical aspects of EBUS-TBNA as they relate to patient, technology, and proceduralist factors to provide evidence-based and expert guidance to clinicians. Rigorous methodology has been applied to provide a trustworthy evidence-based guideline and expert panel report. A group of approved panelists developed key clinical questions by using the PICO (population, intervention, comparator, and outcome) format that addressed specific topics on the technical aspects of EBUS-TBNA. MEDLINE (via PubMed) and the Cochrane Library were systematically searched for relevant literature, which was supplemented by manual searches. References were screened for inclusion, and well-recognized document evaluation tools were used to assess the quality of included studies, to extract meaningful data, and to grade the level of evidence to support each recommendation or suggestion. Our systematic review and critical analysis of the literature on 15 PICO questions related to the technical aspects of EBUS-TBNA resulted in 12 statements: 7 evidence-based graded recommendations and 5 ungraded consensus-based statements. Three questions did not have sufficient evidence to generate a statement. Evidence on the technical aspects of EBUS-TBNA varies in strength but is satisfactory in certain areas to guide clinicians on the best conditions to perform EBUS-guided tissue sampling. Additional research is needed to enhance our knowledge regarding the optimal performance of this effective procedure. Copyright © 2016 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.
Anderson, Wade C.; Boyd, Michael B.; Aguilar, Jorge; Pickell, Brett; Laysang, Amy; Pysz, Marybeth A.; Bheddah, Sheila; Ramoth, Johanna; Slingerland, Brian C.; Dylla, Scott J.; Rubio, Edmundo R.
2015-01-01
Small cell lung cancer (SCLC) is a devastating disease with limited treatment options. Due to its early metastatic nature and rapid growth, surgical resection is rare. Standard of care treatment regimens remain largely unchanged since the 1980’s, and five-year survival lingers near 5%. Patient-derived xenograft (PDX) models have been established for other tumor types, amplifying material for research and serving as models for preclinical experimentation; however, limited availability of primary tissue has curtailed development of these models for SCLC. The objective of this study was to establish PDX models from commonly collected fine needle aspirate biopsies of primary SCLC tumors, and to assess their utility as research models of primary SCLC tumors. These transbronchial needle aspirates efficiently engrafted as xenografts, and tumor histomorphology was similar to primary tumors. Resulting tumors were further characterized by H&E and immunohistochemistry, cryopreserved, and used to propagate tumor-bearing mice for the evaluation of standard of care chemotherapy regimens, to assess their utility as models for tumors in SCLC patients. When treated with Cisplatin and Etoposide, tumor-bearing mice responded similarly to patients from whom the tumors originated. Here, we demonstrate that PDX tumor models can be efficiently established from primary SCLC transbronchial needle aspirates, even after overnight shipping, and that resulting xenograft tumors are similar to matched primary tumors in cancer patients by both histology and chemo-sensitivity. This method enables physicians at non-research institutions to collaboratively contribute to the rapid establishment of extensive PDX collections of SCLC, enabling experimentation with clinically relevant tissues and development of improved therapies for SCLC patients. PMID:25955027
Lee, Kyungjong; Um, Sang-Won; Jeong, Byeong-Ho; Yang, Jung Wook; Choi, Yoon-La; Han, Joungho; Kim, Hojoong; Kwon, O Jung
2016-01-01
Objective A mutational analysis of tumor tissue samples is an important part of advanced lung cancer treatment strategies. This study evaluated the efficacy of a triple gene analysis using samples obtained via endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA). Methods Either metastatic lymph nodes or primary lung mass samples obtained by EBUS-TBNA were collected between May 2011 and May 2013. We consecutively analyzed epidermal growth factor receptor (EGFR), V-Ki-ras2 Kirsten rat sarcoma viral oncogene homolog (KRAS), and anaplastic lymphoma kinase (ALK) fusion genes using remnant tissue samples. Results A total of 109 patients were diagnosed with non-small cell lung cancer (NSCLC). Of these, 70% were adenocarcinoma, 27% squamous cell carcinoma with NSCLC, and 3% were related to other types of lung cancer. EGFR mutations were detected in 23 cases (21.1%), KRAS mutations in 13 cases (11.9%), and ALK fusion genes in 5 cases (4.9%). The ALK fusion genes could not be analyzed in four cases because of insufficient tissue samples remaining after routine histochemistry and an EGFR/KRAS mutation analysis. We found that small biopsy samples from EBUS-TBNA were adequate for performing a triple gene analysis in 97 patients (96%). ALK fusion protein immunohistochemistry (IHC) was 100% consistent with fluorescence in situ hybridization (FISH). Conclusion Small samples obtained by EBUS-TBNA were found to be sufficient for performing a triple gene analysis following routine histology and IHC. ALK IHC showed a very good concordance with FISH for detecting ALK fusion genes. PMID:27803402
De Dominicis, F; Fourdrain, A; Iquille, J; Toublanc, B; François, G; Basille, D; Monconduit, J; Merlusca, G; Jounieaux, V; Andrejak, C; Berna, P
2015-08-01
We studied the non-surgical invasive staging by endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) and we detailed the differences of our series, in order to understand the criteria allowing to achieve a better performance. Retrospective observational study conducted between 2007 and 2011, including all patients with proven NSCLC who underwent EBUS-TBNA. For the 92 EBUS-TBNA performed, we found a sensitivity of 78%, a specificity of 93%, a positive predictive value (PPV) of 98%, a negative predictive value (NPV) of 45%, an accuracy of 80% and a prevalence of lymph node involvement at 84%. A learning curve has been demonstrated and a significant difference was found based on the number of punctures by procedure (P=0.02) or on histological type (P=0.02). By analyzing the data of the literature, we have been able to demonstrate that the accuracy and the negative predictive value are correlated with the prevalence. If we take into account this correlation, we can consider the results of our study close to those of the literature. We highlighted a number of criteria that will influence the diagnostic yield of EBUS-TBNA. While some have already been described, other criteria such as histological type or patient selection criteria are less discussed. The key point is the correlation between the prevalence and EBUS-TBNA results. Results of the assessment of lymph node involvement techniques should be interpreted according to the prevalence of lymph node involvement. Copyright © 2015 Elsevier Masson SAS. All rights reserved.
Fiorelli, Alfonso; Raucci, Antonio; Cascone, Roberto; Reginelli, Alfonso; Di Natale, Davide; Santoriello, Carlo; Capuozzo, Antonio; Grassi, Roberto; Serra, Nicola; Polverino, Mario; Santini, Mario
2017-04-01
We proposed a new virtual bronchoscopy tool to improve the accuracy of traditional transbronchial needle aspiration for mediastinal staging. Chest-computed tomographic images (1 mm thickness) were reconstructed with Osirix software to produce a virtual bronchoscopic simulation. The target adenopathy was identified by measuring its distance from the carina on multiplanar reconstruction images. The static images were uploaded in iMovie Software, which produced a virtual bronchoscopic movie from the images; the movie was then transferred to a tablet computer to provide real-time guidance during a biopsy. To test the validity of our tool, we divided all consecutive patients undergoing transbronchial needle aspiration retrospectively in two groups based on whether the biopsy was guided by virtual bronchoscopy (virtual bronchoscopy group) or not (traditional group). The intergroup diagnostic yields were statistically compared. Our analysis included 53 patients in the traditional and 53 in the virtual bronchoscopy group. The sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy for the traditional group were 66.6%, 100%, 100%, 10.53% and 67.92%, respectively, and for the virtual bronchoscopy group were 84.31%, 100%, 100%, 20% and 84.91%, respectively. The sensitivity ( P = 0.011) and diagnostic accuracy ( P = 0.011) of sampling the paratracheal station were better for the virtual bronchoscopy group than for the traditional group; no significant differences were found for the subcarinal lymph node. Our tool is simple, economic and available in all centres. It guided in real time the needle insertion, thereby improving the accuracy of traditional transbronchial needle aspiration, especially when target lesions are located in a difficult site like the paratracheal station. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Yang, Huizhen; Zhao, Heng; Garfield, David H.; Teng, Jiajun; Han, Baohui; Sun, Jiayuan
2013-01-01
AIMS: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) has shown excellent diagnostic capabilities for mediastinal and hilar lymphadenopathy. However, its value in thoracic non-lymph node lesions is less clear. This study was designed to assess the value of EBUS-TBNA in distinguishing malignant from benign thoracic non-lymph node lesions. METHODS: From October 2009 to August 2011, 552 patients underwent EBUS-TBNA under local anesthesia and with conscious sedation. We retrospectively reviewed 81 of these patients who had tracheobronchial wall-adjacent intrapulmonary or isolated mediastinal non-lymph node lesions. On-site cytological evaluation was not used. Immunohistochemistry (IHC) was performed to distinguish the origin or type of malignancy when necessary. RESULTS: EBUS-TBNA was performed in 68 tracheobronchial wall-adjacent intrapulmonary and 13 isolated mediastinal non-lymph node lesions. Of the 81 patients, 77 (95.1%, 60 malignancies and 17 benignancies) were diagnosed through EBUS-TBNA, including 57 primary lung cancers, 2 mediastinal tumors, 1 pulmonary metastatic adenocarcinoma, 7 inflammation, 5 tuberculosis, 3 mediastinal cysts, 1 esophageal schwannoma, and 1 focal fibrosis. There were four false-negative cases (4.9%). Of the 60 malignancies, there were 9 (15.0%) which originally had no definite histologic origin or type. Thus, IHC was performed, with 7 (77.8%) being subsequently confirmed. Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of EBUS-TBNA in distinguishing malignant from benign lesions were 93.4% (60/64), 100% (17/17), 100% (60/60), 81.0% (17/21), and 95.1% (77/81), respectively. CONCLUSION: EBUS-TBNA is a safe procedure with a high sensitivity for distinguishing malignant from benign thoracic non-lymph node lesions within the reach of EBUS-TBNA, with IHC usually providing a more definitive diagnosis. PMID:23439919
Aljohaney, Ahmed A
2018-01-01
The aim of the study was to evaluate the clinical utility and safety of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) in patients with mediastinal and hilar lymphadenopathy and to explicitly describe the utility of this procedure in patient's outcome. A retrospective review and analysis was conducted on 52 patients with mediastinal or hilar lymphadenopathy who underwent EBUS-TBNA from June 2012 to June 2016. All the patients were evaluated by computed tomography (CT) chest with contrast before EBUS examination. Enlarged mediastinal or hilar lymph node was defined as >1 cm short axis on the enhanced CT. Among the 52 patients studied, 57.7% were presented with mediastinal or hilar lymphadenopathy for diagnosis and 42.3% presented with suspected mediastinal malignancy. Paratracheal stations were the most common site for puncture in 33 lymph nodes (43%). The best diagnostic yield was obtained from subcarinal stations and the lowest yield from the hilar stations. Surgical biopsies confirmed lymphoma in six patients, tuberculosis (TB) in three, sarcoidosis in two and one had metastatic adenocarcinoma of unknown primary. The sensitivity, specificity, positive predictive value, and negative predictive value of EBUS-TBNA for diagnosis of mediastinal and hilar lymph node abnormalities were 78.6%, 100%, 100%, and 80%, respectively. The diagnostic yield of EBUS-TBNA in malignant and benign conditions was 79.0%. EBUS-TBNA is a safe and efficacious procedure which can be performed using conscious sedation with high yields. It can be used for the staging of malignancies as well as for the diagnosis of inflammatory and infectious conditions such as sarcoidosis and TB.
Pillai, Anilkumar; Medford, Andrew R L
2013-01-01
Correct coding is essential for accurate reimbursement for clinical activity. Published data confirm that significant aberrations in coding occur, leading to considerable financial inaccuracies especially in interventional procedures such as endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA). Previous data reported a 15% coding error for EBUS-TBNA in a U.K. service. We hypothesised that greater physician involvement with coders would reduce EBUS-TBNA coding errors and financial disparity. The study was done as a prospective cohort study in the tertiary EBUS-TBNA service in Bristol. 165 consecutive patients between October 2009 and March 2012 underwent EBUS-TBNA for evaluation of unexplained mediastinal adenopathy on computed tomography. The chief coder was prospectively electronically informed of all procedures and cross-checked on a prospective database and by Trust Informatics. Cost and coding analysis was performed using the 2010-2011 tariffs. All 165 procedures (100%) were coded correctly as verified by Trust Informatics. This compares favourably with the 14.4% coding inaccuracy rate for EBUS-TBNA in a previous U.K. prospective cohort study [odds ratio 201.1 (1.1-357.5), p = 0.006]. Projected income loss was GBP 40,000 per year in the previous study, compared to a GBP 492,195 income here with no coding-attributable loss in revenue. Greater physician engagement with coders prevents coding errors and financial losses which can be significant especially in interventional specialties. The intervention can be as cheap, quick and simple as a prospective email to the coding team with cross-checks by Trust Informatics and against a procedural database. We suggest that all specialties should engage more with their coders using such a simple intervention to prevent revenue losses. Copyright © 2013 S. Karger AG, Basel.
Trisolini, Rocco; Cancellieri, Alessandra; Tinelli, Carmine; de Biase, Dario; Valentini, Ilaria; Casadei, Gianpiero; Paioli, Daniela; Ferrari, Franco; Gordini, Giovanni; Patelli, Marco; Tallini, Giovanni
2015-12-01
Experts and scientific society guidelines recommend that rapid on-site evaluation (ROSE) be used with endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) to optimize lung cancer genotyping, but no comparative trial has been carried out to confirm and quantify its usefulness. To assess the influence of ROSE on the yield of EBUS-TBNA for a multigene molecular analysis of lung cancer samples, consecutive patients with suspected or known advanced lung cancer were randomized to undergo EBUS-TBNA without ROSE (EBUS arm) or with ROSE (ROSE arm). The primary end point was the rate of the successful accomplishment of the institution's clinical protocol for molecular profiling of nonsquamous non-small cell lung cancer (EGFR and KRAS testing, followed by ALK testing for tumors with EGFR and KRAS wild-type status). Complete genotyping was achieved in 108 of 126 patients (85.7%) (90.8% in the ROSE arm vs 80.3% in the EBUS arm, P = .09). The patients in the ROSE arm were less likely to have samples that could be used only for pathologic diagnosis because of minimal tumor burden (0 vs 6, P = .05), and were more likely to have the bronchoscopy terminated after a single biopsy site (58.9% vs 44.1%, P = .01). ROSE prevents the need for a repeat invasive diagnostic procedure aimed at molecular profiling in at least one out of 10 patients with advanced lung cancer and significantly reduces the risk of retrieving samples that can be used only for pathologic subtyping because of minimal tumor burden. ClinicalTrials.gov; No.: NCT01799382; URL: www.clinicaltrials.gov.
Diagnostic Yield of Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration
2011-01-01
Background: New transbronchial needle aspiration (TBNA) technologies have been developed, but their clinical effectiveness and determinants of diagnostic yield have not been quantified. Prospective data are needed to determine risk-adjusted diagnostic yield. Methods: We prospectively enrolled patients undergoing TBNA of mediastinal lymph nodes in the American College of Chest Physicians Quality Improvement Registry, Evaluation, and Education (AQuIRE) multicenter database and recorded clinical, procedural, and provider information. All clinical decisions, including type of TBNA used (conventional vs endobronchial ultrasound-guided), were made by the attending bronchoscopist. The primary outcome was obtaining a specific diagnosis. Results: We enrolled 891 patients at six hospitals. Most procedures (95%) were performed with ultrasound guidance. A specific diagnosis was made in 447 cases. Unadjusted diagnostic yields were 37% to 54% for different hospitals, with significant between-hospital heterogeneity (P = .0001). Diagnostic yield was associated with annual hospital TBNA volume (OR, 1.003; 95% CI, 1.000-1.006; P = .037), smoking (OR, 1.55; 95% CI, 1.02-2.34; P = .042), biopsy of more than two sites (OR, 0.57; 95% CI, 0.38-0.85; P = .015), lymph node size (reference > 1-2 cm, ≤ 1 cm: OR, 0.51; 95% CI, 0.34-0.77; P = .003; > 2-3 cm: OR, 2.49; 95% CI, 1.61-3.85; P < .001; and > 3 cm: OR, 3.61; 95% CI, 2.17-6.00; P < .001), and positive PET scan (OR, 3.12; 95% CI, 1.39-7.01; P = .018). Biopsy was performed on more and smaller nodes at high-volume hospitals (P < .0001). Conclusions: To our knowledge, this is the first bronchoscopy study of risk-adjusted diagnostic yields on a hospital-level basis. High-volume hospitals were associated with high diagnostic yields. This study also demonstrates the value of procedural registries as a quality improvement tool. A larger number and variety of participating hospitals is needed to verify these results and to further investigate other determinants of diagnostic yield. PMID:21659432
Chae, In Hye; Kim, Eun-Kyung; Moon, Hee Jung; Yoon, Jung Hyun; Park, Vivian Y; Kwak, Jin Young
2017-07-01
To compare post-biopsy hematoma rates between ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy, and to investigate risk factors for post-biopsy hematoma. A total of 5304 thyroid nodules which underwent ultrasound guided biopsy were included in this retrospective study. We compared clinical and US features between patients with and without post-biopsy hematoma. Associations between these features and post-biopsy hematoma were analyzed. Post-biopsy hematoma rate was 0.8% (43/5121) for ultrasound guided-fine needle aspiration and 4.9% (9/183) for ultrasound guided-core needle biopsy (P < 0.001). For ultrasound guided-fine needle aspiration, gender, age, size, presence of vascularity, and suspicious US features were not associated with post-biopsy hematoma according to experience level. Post-biopsy hematoma occurred significantly more with ultrasound guided-core needle biopsy (9/179, 5.0%) than with ultrasound guided-fine needle aspiration (9/1138, 0.8%) (P < 0.001) in experienced performers and ultrasound guided-core needle biopsy was the only significant risk factor for post-biopsy hematoma (adjusted Odds Ratio, 6.458, P < 0.001). Post-biopsy hematoma occurred significantly more in ultrasound guided-core needle biopsy than in ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy was the only independent factor of post-biopsy hematoma in thyroid nodules.
Casadio, Chiara; Guarize, Juliana; Donghi, Stefano; Di Tonno, Clementina; Fumagalli, Caterina; Vacirca, Davide; Dell'Orto, Patrizia; De Marinis, Filippo; Spaggiari, Lorenzo; Viale, Giuseppe; Barberis, Massimo
2015-10-01
Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a minimally invasive procedure that has revolutionized the diagnosis and staging of lung cancer. The goal of the present study was to investigate the yield and applicability of molecular testing in the specimens obtained by EBUS-TBNA from patients with advanced non-small cell lung cancer (NSCLC), comparing the results with a series of patients who underwent diagnostic surgical procedures in the same institution. The study followed 306 consecutive patients with clinically diagnosed primary lung cancer who had the EBUS-TBNA procedure. EGFR and KRAS mutations were evaluated on cytologic specimens by Sanger sequencing and Cobas real-time polymerase chain reaction, whereas ALK rearrangement was tested by fluorescence in situ hybridization. The results were compared with those obtained from a series of 1,000 NSCLC surgical samples routinely analyzed. Molecular testing was possible in 96.9% of the samples obtained by EBUS-TBNA. EGFR (exons 18-21) mutations were found in 16.9%, KRAS mutation (exons 2-3) in 31.6%, and ALK rearrangement in 3.9% of the cases. In the surgical series, the mutations' distribution were 14.8%, 29.0%, and 3.4%, respectively. There were no statistical differences between the two series. Our study demonstrates that EBUS-TBNA can be effectively used not just for diagnosis but also for complete mutational testing. Copyright© by the American Society for Clinical Pathology.
NASA Astrophysics Data System (ADS)
Li, Jiawen; Quirk, Bryden C.; Noble, Peter B.; Kirk, Rodney W.; Sampson, David D.; McLaughlin, Robert A.
2017-10-01
Transbronchial needle aspiration (TBNA) of small lesions or lymph nodes in the lung may result in nondiagnostic tissue samples. We demonstrate the integration of an optical coherence tomography (OCT) probe into a 19-gauge flexible needle for lung tissue aspiration. This probe allows simultaneous visualization and aspiration of the tissue. By eliminating the need for insertion and withdrawal of a separate imaging probe, this integrated design minimizes the risk of dislodging the needle from the lesion prior to aspiration and may facilitate more accurate placement of the needle. Results from in situ imaging in a sheep lung show clear distinction between solid tissue and two typical constituents of nondiagnostic samples (adipose and lung parenchyma). Clinical translation of this OCT-guided aspiration needle holds promise for improving the diagnostic yield of TBNA.
Han, Yeji; Kim, Hyun Jung; Kong, Kyoung Ae; Kim, Soo Jung; Lee, Su Hwan; Ryu, Yon Ju; Lee, Jin Hwa; Kim, Yookyoung; Shim, Sung Shine
2018-01-01
Background Advances in bronchoscopy and CT-guided lung biopsy have improved the evaluation of small pulmonary lesions (PLs), leading to an increase in preoperative histological diagnosis. We aimed to evaluate the efficacy and safety of transbronchial lung biopsy using radial endobronchial ultrasound and virtual bronchoscopic navigation (TBLB-rEBUS&VBN) and CT-guided transthoracic needle biopsy (CT-TNB) for tissue diagnosis of small PLs. Methods A systematic search was performed in five electronic databases, including MEDLINE, EMBASE, Cochrane Library Central Register of Controlled Trials, Web of Science, and Scopus, for relevant studies in May 2016; the selected articles were assessed using meta-analysis. The articles were limited to those published after 2000 that studied small PLs ≤ 3 cm in diameter. Results From 7345 records, 9 articles on the bronchoscopic (BR) approach and 15 articles on the percutaneous (PC) approach were selected. The pooled diagnostic yield was 75% (95% confidence interval [CI], 69–80) using the BR approach and 93% (95% CI, 90–96) using the PC approach. For PLs ≤ 2 cm, the PC approach (pooled diagnostic yield: 92%, 95% CI: 88–95) was superior to the BR approach (66%, 95% CI: 55–76). However, for PLs > 2 cm but ≤ 3 cm, the diagnostic yield using the BR approach was improved to 81% (95% CI, 75–85). Complications of pneumothorax and hemorrhage were rare with the BR approach but common with the PC approach. Conclusions CT-TNB was superior to TBLB-rEBUS&VBN for the evaluation of small PLs. However, for lesions greater than 2 cm, the BR approach may be considered considering its diagnostic yield of over 80% and the low risk of procedure-related complications. PMID:29357388
Dhooria, Sahajal; Aggarwal, Ashutosh N; Gupta, Dheeraj; Behera, Digambar; Agarwal, Ritesh
2015-07-01
The use of endoscopic ultrasound with bronchoscope-guided fine-needle aspiration (EUS-B-FNA) has been described in the evaluation of mediastinal lymphadenopathy. Herein, we conduct a meta-analysis to estimate the overall diagnostic yield and safety of EUS-B-FNA combined with endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA), in the diagnosis of mediastinal lymphadenopathy. The PubMed and EmBase databases were searched for studies reporting the outcomes of EUS-B-FNA in diagnosis of mediastinal lymphadenopathy. The study quality was assessed using the QualSyst tool. The yield of EBUS-TBNA alone and the combined procedure (EBUS-TBNA and EUS-B-FNA) were analyzed by calculating the sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio for each study, and pooling the study results using a random effects model. Heterogeneity and publication bias were assessed for individual outcomes. The additional diagnostic gain of EUS-B-FNA over EBUS-TBNA was calculated using proportion meta-analysis. Our search yielded 10 studies (1,080 subjects with mediastinal lymphadenopathy). The sensitivity of the combined procedure was significantly higher than EBUS-TBNA alone (91% vs 80%, P = .004), in staging of lung cancer (4 studies, 465 subjects). The additional diagnostic gain of EUS-B-FNA over EBUS-TBNA was 7.6% in the diagnosis of mediastinal adenopathy. No serious complication of EUS-B-FNA procedure was reported. Clinical and statistical heterogeneity was present without any evidence of publication bias. Combining EBUS-TBNA and EUS-B-FNA is an effective and safe method, superior to EBUS-TBNA alone, in the diagnosis of mediastinal lymphadenopathy. Good quality randomized controlled trials are required to confirm the results of this systematic review. Copyright © 2015 by Daedalus Enterprises.
Ohshimo, Shinichiro; Guzman, Josune; Costabel, Ulrich; Bonella, Francesco
2017-09-30
Granulomatous lung diseases are a heterogeneous group of disorders that have a wide spectrum of pathologies with variable clinical manifestations and outcomes. Precise clinical evaluation, laboratory testing, pulmonary function testing, radiological imaging including high-resolution computed tomography and often histopathological assessment contribute to make a confident diagnosis of granulomatous lung diseases. Differential diagnosis is challenging, and includes both infectious (mycobacteria and fungi) and noninfectious lung diseases (sarcoidosis, necrotising sarcoid granulomatosis, hypersensitivity pneumonitis, hot tub lung, berylliosis, granulomatosis with polyangiitis, eosinophilic granulomatosis with polyangiitis, rheumatoid nodules, talc granulomatosis, Langerhans cell histiocytosis and bronchocentric granulomatosis). Bronchoalveolar lavage, endobronchial ultrasound-guided transbronchial needle aspiration, transbronchial cryobiopsy, positron emission tomography and genetic evaluation are potential candidates to improve the diagnostic accuracy for granulomatous lung diseases. As granuloma alone is a nonspecific histopathological finding, the multidisciplinary approach is important for a confident diagnosis. Copyright ©ERS 2017.
Costa, Daniel B.; Wright, Jeffrey; VanderLaan, Paul A.
2015-01-01
The diagnosis and staging of patients with lung cancer in recent decades has increasingly relied on minimally invasive tissue sampling techniques, such as endobronchial ultrasound (EBUS) or endoscopic ultrasound (EUS) needle aspiration, transbronchial biopsy, and transthoracic image guided core needle biopsy. These modalities have been shown to have low complication rates, and provide adequate cellular material for pathologic diagnosis and necessary ancillary molecular testing. As an important component to a multidisciplinary team approach in the care of patients with lung cancer, these minimally invasive modalities have proven invaluable for the rapid and safe acquisition of tissue used for the diagnosis, staging, and molecular testing of tumors to identify the best evidence-based treatment plan. The continuous evolution of the field of lung cancer staging and treatment has translated into improvements in survival and quality of life for patients. Although differences in clinical practice between academic and community hospital settings still exist, improvements in physician education and training as well as adoption of technological advancements should help narrow this gap going forward. PMID:26380180
Transbronchial needle aspiration with a new electromagnetically-tracked TBNA needle
NASA Astrophysics Data System (ADS)
Choi, Jae; Popa, Teo; Gruionu, Lucian
2009-02-01
Transbronchial needle aspiration (TBNA) is a common method used to collect tissue for diagnosis of different chest diseases and for staging lung cancer, but the procedure has technical limitations. These limitations are mostly related to the difficulty of accurately placing the biopsy needles into the target mass. Currently, pulmonologists plan TBNA by examining a number of Computed Tomography (CT) scan slices before the operation. Then, they manipulate the bronchoscope down the respiratory track and blindly direct the biopsy. Thus, the biopsy success rate is low. The diagnostic yield of TBNA is approximately 70 percent. To enhance the accuracy of TBNA, we developed a TBNA needle with a tip position that can be electromagnetically tracked. The needle was used to estimate the bronchoscope's tip position and enable the creation of corresponding virtual bronchoscopic images from a preoperative CT scan. The TBNA needle was made with a flexible catheter embedding Wang Transbronchial Histology Needle and a sensor tracked by electromagnetic field generator. We used Aurora system for electromagnetic tracking. We also constructed an image-guided research prototype system incorporating the needle and providing a user-friendly interface to assist the pulmonologist in targeting lesions. To test the feasibility of the accuracy of the newly developed electromagnetically-tracked needle, a phantom study was conducted in the interventional suite at Georgetown University Hospital. Five TBNA simulations with a custom-made phantom with a bronchial tree were performed. The experimental results show that our device has potential to enhance the accuracy of TBNA.
A mass that has no (EBUS) echo.
Rosenblum, Matthew K; Wang, Sue X; Seeley, Eric J
2018-01-01
We report findings for a patient that underwent endobronchial ultrasound (EBUS) guided transbronchial needle aspiration (TBNA) for diagnostic purposes after an abnormal chest CT. The patient initially presented with cough and shortness of breath. Chest CT revealed a 6 cm soft tissue mass with mildly enlarged right hilar lymph nodes (LNs) and a small right sided pleural effusion. Based on these radiologic findings, the patient underwent an EBUS guided FNA of the mass. To our surprise, the mass was hypoechoic by EBUS and on aspiration, the syringe filled with yellow fluid. This finding in combination with a re-review of the CT scans with a special focus on the Hounsfield Units of the lesion confirmed the diagnosis of a mediastinal bronchogenic cyst. This case demonstrates the role of Hounsfield units in analyzing mediastinal masses and highlights the effectiveness of EBUS guided TBNA in diagnosis and treatment of bronchogenic cysts.
Hofstad, Erlend Fagertun; Amundsen, Tore; Langø, Thomas; Bakeng, Janne Beate Lervik; Leira, Håkon Olav
2017-01-01
Background Endobronchial ultrasound transbronchial needle aspiration (EBUS-TBNA) is the endoscopic method of choice for confirming lung cancer metastasis to mediastinal lymph nodes. Precision is crucial for correct staging and clinical decision-making. Navigation and multimodal imaging can potentially improve EBUS-TBNA efficiency. Aims To demonstrate the feasibility of a multimodal image guiding system using electromagnetic navigation for ultrasound bronchoschopy in humans. Methods Four patients referred for lung cancer diagnosis and staging with EBUS-TBNA were enrolled in the study. Target lymph nodes were predefined from the preoperative computed tomography (CT) images. A prototype convex probe ultrasound bronchoscope with an attached sensor for position tracking was used for EBUS-TBNA. Electromagnetic tracking of the ultrasound bronchoscope and ultrasound images allowed fusion of preoperative CT and intraoperative ultrasound in the navigation software. Navigated EBUS-TBNA was used to guide target lymph node localization and sampling. Navigation system accuracy was calculated, measured by the deviation between lymph node position in ultrasound and CT in three planes. Procedure time, diagnostic yield and adverse events were recorded. Results Preoperative CT and real-time ultrasound images were successfully fused and displayed in the navigation software during the procedures. Overall navigation accuracy (11 measurements) was 10.0 ± 3.8 mm, maximum 17.6 mm, minimum 4.5 mm. An adequate sample was obtained in 6/6 (100%) of targeted lymph nodes. No adverse events were registered. Conclusions Electromagnetic navigated EBUS-TBNA was feasible, safe and easy in this human pilot study. The clinical usefulness was clearly demonstrated. Fusion of real-time ultrasound, preoperative CT and electromagnetic navigational bronchoscopy provided a controlled guiding to level of target, intraoperative overview and procedure documentation. PMID:28182758
Arias, Sixto; Lee, Hans; Semaan, Roy; Frimpong, Bernice; Ortiz, Ricardo; Feller-Kopman, David; Oakjones-Burgess, Karen; Yarmus, Lonny
2015-05-23
Lung nodule evaluation represents a clinical challenge especially in patients with intermediate risk for malignancy. Multiple technologies are presently available to sample nodules for pathological diagnosis. Those technologies can be divided into bronchoscopic and non-bronchoscopic interventions. Electromagnetic navigational bronchoscopy is being extensively used for the endobronchial approach to peripheral lung nodules but has been hindered by anatomic challenges resulting in a 70% diagnostic yield. Electromagnetic navigational guided transthoracic needle lung biopsy is novel non-bronchoscopic method that uses a percutaneous electromagnetic tip tracked needle to obtain core biopsy specimens. Electromagnetic navigational transthoracic needle aspiration complements bronchoscopic techniques potentially allowing the provider to maximize the diagnostic yield during one single procedure. This article describes a novel integrated diagnostic approach to pulmonary lung nodules. We propose the use of endobronchial ultrasound transbronchial needle aspiration (EBUS-TBNA) for mediastinal staging; radial EBUS, navigational bronchoscopy and E-TTNA during one single procedure to maximize diagnostic yield and minimize the number of invasive procedures needed to obtain a diagnosis. This manuscript describes in detail how the navigation transthoracic procedure is performed. Additional clinical studies are needed to determine the clinical utility of this novel technology.
Inage, Terunaga; Nakajima, Takahiro; Itoga, Sakae; Ishige, Takayuki; Fujiwara, Taiki; Sakairi, Yuichi; Wada, Hironobu; Suzuki, Hidemi; Iwata, Takekazu; Chiyo, Masako; Yoshida, Shigetoshi; Matsushita, Kazuyuki; Yasufuku, Kazuhiro; Yoshino, Ichiro
2018-06-13
The limited negative predictive value of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) has often been discussed. The aim of this study was to identify a highly sensitive molecular biomarker for lymph node staging by EBUS-TBNA. Five microRNAs (miRNAs) (miR-200a, miR-200b, miR-200c, miR-141, and let-7e) were selected as biomarker candidates for the detection of nodal metastasis in a miRNA expression analysis. After having established a cutoff level of expression for each marker to differentiate malignant from benign lymph nodes among surgically dissected lymph nodes, the cutoff level was applied to snap-frozen EBUS-TBNA samples. Archived formalin-fixed paraffin- embedded (FFPE) samples rebiopsied by EBUS-TBNA after induction chemoradiotherapy were also analyzed. The expression of all candidate miRNAs was significantly higher in metastatic lymph nodes than in benign ones (p < 0.05) among the surgical samples. miR-200c showed the highest diagnostic yield, with a sensitivity of 95.4% and a specificity of 100%. When the cutoff value for miR-200c was applied to the snap-frozen EBUS-TBNA samples, the sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy were 97.4, 81.8, 95.0, 90.0, and 94.0%, respectively. For restaging FFPE EBUS- TBNA samples, the sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy were 100, 60.0, 80.0, 100, and 84.6%, respectively. Among the restaged samples, 4 malignant lymph nodes were false negative by EBUS-TBNA, but they were accurately identified by miR-200c. miR-200c can be used as a highly sensitive molecular staging biomarker that will enhance nodal staging of lung cancer. © 2018 S. Karger AG, Basel.
Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid
... News Physician Resources Professions Site Index A-Z Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid ... Needle Aspiration Biopsy of the Thyroid? What is Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid? ...
A survey of flexible bronchoscopy practices in India: The Indian bronchoscopy survey (2017)
Madan, Karan; Mohan, Anant; Agarwal, Ritesh; Hadda, Vijay; Khilnani, Gopi C; Guleria, Randeep
2018-01-01
Background: There is a lack of contemporaneous data on the practices of flexible bronchoscopy in India. Aim: The aim of the study was to study the prevalent practices of flexible bronchoscopy across India. Methods: The “Indian Bronchoscopy Survey” was a 98-question, online survey structured into the following sections: general information, patient preparation and monitoring, sedation and topical anesthesia, procedural/technical aspects, and bronchoscope disinfection/staff protection. Results: Responses from 669 bronchoscopists (mean age: 40.2 years, 91.8% adult pulmonologists) were available for analysis. Approximately, 70,000 flexible bronchoscopy examinations had been performed over the preceding year. A majority (59%) of bronchoscopists were performing bronchoscopy without sedation. A large number (45%) of bronchoscopists had learned the procedure outside of their fellowship training. About 55% used anticholinergic premedication either as a routine or occasionally. Nebulized lignocaine was being used by 72%, while 24% utilized transtracheal administration of lignocaine. The most commonly (75%) used concentration of lignocaine was 2%. Midazolam with or without fentanyl was the preferred agent for intravenous sedation. The use of video bronchoscope was common (80.8%). The most common (94%) route for performing bronchoscopy was nasal. Conventional transbronchial needle aspiration (TBNA) was being performed by 74%, while 92% and 78% performed endobronchial and transbronchial lung biopsy, respectively. Therapeutic airway interventions (stents, electrocautery, cryotherapy, and others) were being performed by 30%, while endobronchial ultrasound guided transbronchial needle aspiration (EBUS-TBNA) and rigid bronchoscopy were performed by 27% and 19.5%, respectively. Conclusion: There is a wide national variation in the practices of performing flexible bronchoscopy. However, there has been a considerable improvement in bronchoscopy practices compared to previous national surveys. PMID:29487243
A survey of flexible bronchoscopy practices in India: The Indian bronchoscopy survey (2017).
Madan, Karan; Mohan, Anant; Agarwal, Ritesh; Hadda, Vijay; Khilnani, Gopi C; Guleria, Randeep
2018-01-01
There is a lack of contemporaneous data on the practices of flexible bronchoscopy in India. The aim of the study was to study the prevalent practices of flexible bronchoscopy across India. The "Indian Bronchoscopy Survey" was a 98-question, online survey structured into the following sections: general information, patient preparation and monitoring, sedation and topical anesthesia, procedural/technical aspects, and bronchoscope disinfection/staff protection. Responses from 669 bronchoscopists (mean age: 40.2 years, 91.8% adult pulmonologists) were available for analysis. Approximately, 70,000 flexible bronchoscopy examinations had been performed over the preceding year. A majority (59%) of bronchoscopists were performing bronchoscopy without sedation. A large number (45%) of bronchoscopists had learned the procedure outside of their fellowship training. About 55% used anticholinergic premedication either as a routine or occasionally. Nebulized lignocaine was being used by 72%, while 24% utilized transtracheal administration of lignocaine. The most commonly (75%) used concentration of lignocaine was 2%. Midazolam with or without fentanyl was the preferred agent for intravenous sedation. The use of video bronchoscope was common (80.8%). The most common (94%) route for performing bronchoscopy was nasal. Conventional transbronchial needle aspiration (TBNA) was being performed by 74%, while 92% and 78% performed endobronchial and transbronchial lung biopsy, respectively. Therapeutic airway interventions (stents, electrocautery, cryotherapy, and others) were being performed by 30%, while endobronchial ultrasound guided transbronchial needle aspiration (EBUS-TBNA) and rigid bronchoscopy were performed by 27% and 19.5%, respectively. There is a wide national variation in the practices of performing flexible bronchoscopy. However, there has been a considerable improvement in bronchoscopy practices compared to previous national surveys.
Madan, Neha Kawatra; Madan, Karan; Jain, Deepali; Walia, Ritika; Mohan, Anant; Hadda, Vijay; Mathur, Sandeep; Iyer, Venkateswaran K; Khilnani, Gopi C; Guleria, Randeep
2016-01-01
Background: Conventional transbronchial needle aspiration (c-TBNA) is an underutilized bronchoscopic modality. Endobronchial ultrasound (EBUS) guided-TBNA though efficacious is an expensive modality, facilities of which are available at only limited centers. c-TBNA is cost-effective and has potential for wide utilization especially in resource-limited settings. Rapid on-site evaluation (ROSE) improves the yield of c-TBNA. Materials and Methods: A retrospective review of the bronchoscopy records (May 2012 to July 2014) was performed. The patients who underwent c-TBNA with ROSE were included in the study and their clinical details were extracted. Convex probe EBUS-TBNA was being regularly performed during the study period by the operators performing c-TBNA. Results: c-TBNA with ROSE was performed in 41 patients with mean age of 42.4 (16.2) years. The most frequently sampled node stations (>90% patients) were the subcarinal and lower right paratracheal. Representative samples could be obtained in 33 out of the 41 patients (80.4%). c-TBNA was diagnostic in 32 [tuberculosis (TB)-8, sarcoidosis-9, and malignancy-15] patients out of the 41 patients. The overall diagnostic yield (sensitivity) of c-TBNA with ROSE was 78%. Mean procedure duration was 18.4 (3.1) min and there were no procedural complications. Conclusion: c-TBNA with ROSE is a safe, efficacious, and cost-effective bronchoscopic modality. When it was performed by operators routinely performing EBUS-TBNA, diagnostic yields similar to that of EBUS-TBNA can be obtained. Even at the centers where EBUS facilities are available, c-TBNA should be routinely performed. PMID:27011437
Liu, Qinghua; Han, Songyan; Arias, Sixto; Turner, J Francis; Lee, Hans; Browning, Robert; Wang, Ko-Pen
2016-01-01
The role of transbronchial needle aspiration (TBNA) in the diagnosis and staging of lung cancer has been well established. Recently, the efficacy of conventional TBNA in the staging of lung cancer has been enhanced by the use of endobronchial ultrasound (EBUS)-TBNA. Our study sought to evaluate the adequacy of TBNA of International Association for the Study of Lung Cancer (IASLC) stations 4R, 4L and 7 using endobronchial landmarks provided by the Wang nodal mapping system in the staging of lung cancer. We retrospectively analyzed all bronchoscopic cases with conventional TBNA punctures positive for malignancy at our institution from 1 January to 31 October 2014. The endobronchial puncture site was guided by the Wang nodal mapping system. The Wang stations were correlated with the IASLC lymph node map. No endobronchial ultrasound or rapid on-site evaluation was used. Pathological analysis included cytological and histological examination. Diagnosis by histological analysis was obtained in 115 (55.3%) out of 208 puncture sites. The metastatic lymph nodes were distributed at IASLC stations 4R (W1, 3, 5) 46.6 %, 7 (W2, 8, 10) 19.7%, 4L (W4, 6) 11.5%, 11R (W7, W9) 11.1% 11L (W11) 9.6%, 2R (high station W3) 0.5%, and the proximal portion of station 8 (station W10 beyond the middle lobe orifice) 1%. No complications were observed. IASLC station 4R (W1, 3, 5), 7 (W2, 8, 10) and 4L (W4, 6) are adequate for the staging of lung cancer.
Sarcoidosis with Pancreatic Mass, Endobronchial Nodules, and Miliary Opacities in the Lung.
Matsuura, Shun; Mochizuka, Yasutaka; Oishi, Kyohei; Miyashita, Koichi; Naoi, Hyogo; Mochizuki, Eisuke; Mikura, Shinichiro; Tsukui, Masaru; Koshimizu, Naoki; Ohata, Akihiko; Suda, Takahumi
2017-11-15
Sarcoidosis affects multiple organs and rarely has unusual manifestations. A 78-year-old woman was referred to our hospital for coughing symptoms. A chest computed tomography (CT) scan revealed bilateral diffuse miliary patterns and right pleural effusion. Bronchoscopy showed multiple nodules in the carina and the bronchus intermedius. A CT scan of her abdomen revealed hypovascular lesions involving the pancreatic head and body. A transbronchial lung biopsy, bronchial mucosal biopsy, and endoscopic ultrasound-guided fine-needle aspiration of the pancreatic mass demonstrated non-caseating granulomas. We diagnosed the patient with sarcoidosis. She received no treatment for sarcoidosis and has been followed up for one year, during which no pulmonary disease progression had been observed and the pancreatic masses partially regressed.
Videothoracoscopy in the treatment of mediastinal cysts
Brzeziński, Daniel; Kozak, Józef
2014-01-01
Introduction Progress in the development of surgical techniques has led to the growing use of video-assisted thoracoscopic surgery (VATS) techniques in mediastinal cyst treatment. Aim To present our experience of treating mediastinal cysts with the minimally invasive technique. Material and methods Fifty patients with mediastinal cysts were treated from 2001 to 2011. There were 32 women and 18 men. The age of the patients ranged from 17 to 72, the mean age being 42 years. All patients underwent basic preoperative diagnostic tests of the chest: X-ray, computed tomography (CT), bronchoscopy and spirometry; 4 patients underwent endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) and 3 fine needle aspiration biopsy (FNAB) of the described lesions. Results The VATS was performed in each case. Conversion was carried out due to superior mediastinal location in 10 cases and pleural adhesions in 3 cases. The partial resection of a cyst was performed in 3 patients. One patient was treated conservatively due to heart failure. In that patient the transthoracic needle aspiration of a cyst under ultrasound guidance using alcoholisation with 76% ethanol with a good effect was performed twice. Cyst recurrence was observed in 1 case. Conclusions The surgical access depends on the location of a cyst. The VATS resection of a superior mediastinal cyst is not always feasible. Surgery of mediastinal cysts is both diagnostic and curative. PMID:25337163
Comparison of Sample Adequacy and Diagnostic Yield of 19- and 22-G EBUS-TBNA Needles.
Chaddha, Udit; Ronaghi, Reza; Elatre, Waafa; Chang, Ching-Fei; Mahdavi, Ramyar
2018-05-16
The 2016 CHEST consensus guidelines recommend use of either 21- or 22-G needles for endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA). We decided to prospectively compare sample adequacy and diagnostic yield of the 19-G with the 22-G EBUS needle, hypothesizing that a larger gauge difference might magnify the differences between 2 needle sizes. Twenty-seven patients undergoing EBUS-TBNA at our institution were evaluated. All cases were performed by a single operator formally trained in interventional pulmonology. Both Olympus 19- and 22-G needles were used at each lymph node station in an alternating manner. Rapid on-site cytology evaluation was used and a separate cell block was prepared for each needle at each station. Fifty-six lymph nodes were analyzed. Diagnoses included cancer (36%, including 1 lymphoma), reactive lymphoid tissue (53%), and sarcoidosis (11%). One hundred sixty-two and 163 passes were made with the 22- and 19-G needle, respectively. Sample adequacy was 73% and 46% with the 22 and 19-G needle, respectively (P<0.001). Significantly fewer passes were bloody with the 22-G compared with the 19-G needle (19% vs. 59%; P<0.001). Diagnostic yield was not different between the 22- and 19-G needles (95% vs. 93%; P=0.62). In addition to no difference in diagnostic yield, the 19-G needle yielded samples that were frequently less adequate and more often bloody compared with the 22-G needle. Despite the larger caliber lumen, we conclude that the 19-G needle does not confer a diagnostic advantage.
Slavova-Azmanova, Neli S.; Phillips, Martin; Trevenen, Michelle L.; Li, Ian W.; Johnson, Claire E.
2018-01-01
Background Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) and guide sheath (EBUS-GS) are gaining popularity for diagnosis and staging of lung cancer compared to CT-guided transthoracic needle aspiration (CT-TTNA), blind fiber-optic bronchoscopy, and mediastinoscopy. This paper aimed to examine predictors of higher costs for diagnosing and staging lung cancer, and to assess the effect of EBUS techniques on hospital cost. Material/Methods Hospital costs for diagnosis and staging of new primary lung cancer patients presenting in 2007–2008 and 2010–2011 were reviewed retrospectively. Multiple linear regression was used to determine relationships with hospital cost. Results We reviewed 560 lung cancer patient records; 100 EBUS procedures were performed on 90 patients. Higher hospital costs were associated with: EBUS-TBNA performed (p<0.0001); increasing inpatient length of stay (p<0.0001); increasing number of other surgical/diagnostic procedures (p<0.0001); whether the date of management decision fell within an inpatient visit (p<0.0001); and if the patient did not have a CT-TTNA, then costs increased as the number of imaging events increased (interaction p<0.0001). Cohort was not significantly related to cost. Location of the procedure (outside vs. inside theater) was a predictor of lower one-day EBUS costs (p<0.0001). Cost modelling revealed potential cost saving of $1506 per EBUS patient if all EBUS procedures were performed outside rather than in the theater ($66,259 per annum). Conclusions EBUS-TBNA only was an independent predictor of higher cost for diagnosis and staging of lung cancer. Performing EBUS outside compared to in the theater may lower costs for one-day procedures; potential future savings are considerable if more EBUS procedures could be performed outside the operating theater. PMID:29377878
Bigeleisen, Paul E
2017-05-15
Needle guides may allow the practitioner to align the needle with the probe when ultrasound-guided nerve block is performed. The author's goal was to design and fabricate an inexpensive ($1.90), disposable, needle guide that could articulate over a range from 85 degrees to 0 degrees with a three-dimension printer. Three-dimensional representations of an L50, L25, and C 60 ultrasound probe (Sono Site, Bothell, WA) were created using a laser scanner. Computer-aided design software (Solid Works, Waltham, MA) was used to design a needle bracket and needle guide to attach to these probes. A three-dimensional printer was used to fabricate the needle bracket and guide with acrylonitrile polybutadiene polystyrene. An echogenic needle was held in plane with the needle guide. The author performed a supraclavicular block in a morbidly obese patient. The needle was easily visualized. Similar guides that are commercially available cost as much as $400. A knowledge of computer-aided design is necessary for this work.
Bramley, Kyle; Pisani, Margaret A.; Murphy, Terrence E.; Araujo, Katy; Homer, Robert; Puchalski, Jonathan
2016-01-01
Background EBUS-guided transbronchial needle aspiration (TBNA) is important in the evaluation of thoracic lymphadenopathy. Reliably providing excellent diagnostic yield for malignancy, its diagnosis of sarcoidosis is inconsistent. Furthermore, when larger “core” biopsy samples of malignant tissue are required, TBNA may not suffice. The primary objective of this study was to determine if the sequential use of TBNA and a novel technique called cautery-assisted transbronchial forceps biopsies (ca-TBFB) was safe. Secondary outcomes included sensitivity and successful acquisition of tissue. Methods Fifty unselected patients undergoing convex probe EBUS were prospectively enrolled. Under EBUS guidance, all lymph nodes ≥ 1 cm were sequentially biopsied using TBNA and ca-TBFB. Safety and sensitivity were assessed at the nodal level for 111 nodes. Results of each technique were also reported on a per-patient basis. Results There were no significant adverse events. In nodes determined to be malignant, TBNA provided higher sensitivity (100%) than ca-TBFB (78%). However, among nodes with granulomatous inflammation, ca-TBFB exhibited higher sensitivity (90%) than TBNA (33%). For analysis based on patients rather than nodes, 6 of the 31 patients with malignancy would have been missed or understaged if the diagnosis was based on samples obtained by ca-TBFB. On the other hand, 3 of 8 patients with sarcoidosis would have been missed if analysis was based only on TBNA samples. In some cases only ca-TBFB acquired sufficient tissue for the core samples needed in clinical trials of malignancy. Conclusions The sequential use of TBNA and ca-TBFB appears to be safe. The larger samples obtained from ca-TBFB increased its sensitivity to detect granulomatous disease and provided specimens for clinical trials of malignancy when needle biopsies were insufficient. For thoracic surgeons and advanced bronchoscopists, we advocate ca-TBFB as an alternative to TBNA in select clinical scenarios. PMID:26912301
Schmid-Bindert, Gerald; Wang, Yongsheng; Jiang, Hongbin; Sun, Hui; Henzler, Thomas; Wang, Hao; Pilz, Lothar R.; Ren, Shengxiang; Zhou, Caicun
2013-01-01
Background Multiple biomarker testing is necessary to facilitate individualized treatment of lung cancer patients. More than 80% of lung cancers are diagnosed based on very small tumor samples. Often there is not enough tissue for molecular analysis. We compared three minimal invasive sampling methods with respect to RNA quantity for molecular testing. Methods 106 small biopsies were prospectively collected by three different methods forceps biopsy, endobronchial ultrasound (EBUS) guided transbronchial needle aspiration (TBNA), and CT-guided core biopsy. Samples were split into two halves. One part was formalin fixed and paraffin embedded for standard pathological evaluation. The other part was put in RNAlater for immediate RNA/DNA extraction. If the pathologist confirmed the diagnosis of non-small cell lung cancer(NSCLC), the following molecular markers were tested: EGFR mutation, ERCC1, RRM1 and BRCA1. Results Overall, RNA-extraction was possible in 101 out of 106 patients (95.3%). We found 49% adenocarcinomas, 38% squamouscarcinomas, and 14% non-otherwise-specified(NOS). The highest RNA yield came from endobronchial ultrasound guided needle aspiration, which was significantly higher than bronchoscopy (37.74±41.09 vs. 13.74±15.53 ng respectively, P = 0.005) and numerically higher than CT-core biopsy (37.74±41.09 vs. 28.72±44.27 ng respectively, P = 0.244). EGFR mutation testing was feasible in 100% of evaluable patients and its incidence was 40.8%, 7.9% and 14.3% in adenocarcinomas, squamouscarcinomas and NSCLC NOS subgroup respectively. There was no difference in the feasibility of molecular testing between the three sampling methods with feasibility rates for ERCC1, RRM1 and BRCA1 of 91%, 87% and 81% respectively. Conclusion All three methods can provide sufficient tumor material for multiple biomarkers testing from routinely obtained small biopsies in lung cancer patients. In our study EBUS guided needle aspiration provided the highest amount of tumor RNA compared to bronchoscopy or CT guided core biopsy. Thus EBUS should be considered as an acceptable option for tissue acquisition for molecular testing. PMID:24205040
Sehgal, Inderpaul Singh; Dhooria, Sahajal; Aggarwal, Ashutosh Nath; Agarwal, Ritesh
2018-04-01
Whether the use of rapid on-site cytologic evaluation (ROSE) increases the diagnostic yield of transbronchial needle aspiration (TBNA) remains unclear. This article is a systematic review of studies describing the utility of ROSE in subjects undergoing TBNA. The study included a systematic review of the PubMed, Embase, and Scopus databases for randomized controlled trials investigating the diagnostic yield of conventional transbronchial needle aspiration (c-TBNA) or endobronchial ultrasound (EBUS)-TBNA, with or without ROSE, in subjects with mediastinal lymphadenopathy. Five studies (618 subjects; two EBUS-TBNA, two c-TBNA, and one both) were identified. Overall, the studies were of good quality. The pooled risk difference (95% CI) of the diagnostic yield of EBUS-TBNA and c-TBNA was 0.04 (-0.01 to 0.09) and 0.12 (-0.08 to 0.33), respectively, suggesting no added benefit with ROSE. The use of ROSE during EBUS-TBNA (but not c-TBNA) resulted in significantly fewer needle passes (mean difference [95% CI], -1.1 [-2.2 to -0.005]; P < .001). There was no difference in the procedure time during EBUS-TBNA. The complication rate was significantly lower (OR [95% CI], 0.26 [0.10 to 0.71]; P = .009) when ROSE was used during c-TBNA due to fewer additional procedures required to make a diagnosis. There was evidence of heterogeneity in the studies involving c-TBNA but not EBUS-TBNA. There was no publication bias. The use of ROSE neither improved the diagnostic yield nor reduced the procedure time during TBNA. However, the use of ROSE was associated with fewer number of needle passes during EBUS-TBNA and overall lower requirement for additional bronchoscopy procedures during TBNA to make a final diagnosis. PROSPERO; No.: CRD42017058937; URL: www.crd.york.ac.uk/prospero/. Copyright © 2017 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.
Use of an Additional 19-G EBUS-TBNA Needle Increases the Diagnostic Yield of EBUS-TBNA.
Garrison, Garth; Leclair, Timothy; Balla, Agnes; Wagner, Sarah; Butnor, Kelly; Anderson, Scott R; Kinsey, C Matthew
2018-06-12
Although endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) has an excellent diagnostic yield, there remain cases where the diagnosis is not obtained. We hypothesized that additional sampling with a 19-G EBUS-TBNA needle may increase diagnostic yield in a subset of cases where additional tissue sampling was required. Indications for use of the 19-G needle following 22-G sampling with rapid on-site cytologic examination were: (1) diagnostic uncertainty of the on-site cytopathologist (eg, nondiagnostic, probable lymphoma, etc.), (2) non-small cell lung cancer with probable need for molecular genetic and/or PD-L1 testing, or (3) need for a larger tissue sample for consideration of inclusion in a research protocol. A 19-G EBUS-TBNA needle was utilized following standard sampling with a 22-G needle in 48 patients (50 sites) during the same procedure. Although the diagnostic yield between the needles was equivalent, the concordance rate was only 83%. The 19-G determined a diagnosis in 4 additional patients (8%) and provided additional histopathologic information in 6 other cases (12%). Conversely, in 3 cases (6%) diagnostic information was provided only by the 22-G needle. Compared with 22-G EBUS-TBNA alone, sampling with both the 22- and 19-G EBUS needles resulted in an increase in diagnostic yield from 92% to 99% (P=0.045) and a number needed to sample of 13 patients to provide one additional diagnosis. There were no significant complications. In select cases where additional tissue may be needed, sampling with a 19-G EBUS needle following standard aspiration with a 22-G needle results in an increase in diagnostic yield.
Wong, Simon W; Niazi, Ahtsham U; Chin, Ki J; Chan, Vincent W
2013-01-01
The SonixGPS® is an electromagnetic needle tracking system for ultrasound-guided needle intervention. Both current and predicted needle tip position are displayed on the ultrasound screen in real-time, facilitating needle-beam alignment and guidance to the target. This case report illustrates the use of the SonixGPS system for successful performance of real-time ultrasound-guided spinal anesthesia in a patient with difficult spinal anatomy. A 67-yr-old male was admitted to our hospital to undergo revision of total right hip arthroplasty. His four previous arthroplasties for hip revision were performed under general anesthesia because he had undergone L3-L5 instrumentation for spinal stenosis. The L4-L5 interspace was viewed with the patient in the left lateral decubitus position. A 19G 80-mm proprietary needle (Ultrasonix Medical Corp, Richmond, BC, Canada) was inserted and directed through the paraspinal muscles to the ligamentum flavum in plane to the ultrasound beam. A 120-mm 25G Whitacre spinal needle was then inserted through the introducer needle in a conventional fashion. Successful dural puncture was achieved on the second attempt, as indicated by a flow of clear cerebrospinal fluid. The patient tolerated the procedure well, and the spinal anesthetic was adequate for the duration of the surgery. The SonixGPS is a novel technology that can reduce the technical difficulty of real-time ultrasound-guided neuraxial blockade. It may also have applications in other advanced ultrasound-guided regional anesthesia techniques where needle-beam alignment is critical.
Lam, Nicholas C K; Baker, Elizabeth B; Fishburn, Steven J; Hammer, Angie R; Petersen, Timothy R; Mariano, Edward R
2016-07-01
Learning ultrasound-guided regional anesthesia skills, especially needle/ beam alignment, can be especially difficulty for trainees, who can often become frustrated. We hypothesized that teaching novices to orient the transducer and needle perpendicular to their shoulders will improve performance on a standardized task, compared to holding the transducer and needle parallel to the shoulders. This study compared the effects of transducer orientation on trainees' ability to complete a standardized ultrasound-guided nerve block simulation. The time to task completion and percentage of the attempt time without adequate needle visualization were measured. Participants were right-handed healthy adults with no previous ultrasound experience and were randomly assigned to training in either transducer and needle alignment in a coronal plane, parallel to the shoulders (parallel group) or transducer and needle alignment in a sagittal plane, perpendicular to the shoulders (perpendicular group). Participants used ultrasound to direct a needle to 3 targets in a standardized gelatin phantom and repeated this task 3 times. Their efforts were timed and evaluated by an assessor, who was blinded to group assignment. Data were analyzed on 28 participants. The perpendicular group was able to complete the task more quickly (P < .001) and with a smaller proportion of time lost to inadequate needle visualization (P < .001). Ultrasound-guided regional anesthesia trainees complete a standardized task more quickly and efficiently when instructed to hold the transducer and needle in an orientation perpendicular to their shoulders.
Disinfection of a probe used in ultrasound-guided prostate biopsy.
Rutala, William A; Gergen, Maria F; Weber, David J
2007-08-01
Transrectal ultrasound (TRUS)-guided prostate biopsies are among the most common outpatient diagnostic procedures in urology clinics and carry the risk of introducing pathogens that may lead to infection. To investigate the effectiveness of procedures for disinfecting a probe used in ultrasound-guided prostate biopsy. The effectiveness of disinfection was determined by inoculating 10(7) colony forming units (cfu) of Pseudomonas aeruginosa at the following 3 sites on the probe: the interior lumen of the biopsy needle guide, the outside surface of the biopsy needle guide, and the interior lumen of the ultrasound probe where the needle guide passes through the transducer. Each site was investigated separately. After inoculation, the probe was immersed in 2% glutaraldehyde for 20 minutes and then assessed for the level of microbial contamination. The results demonstrated that disinfection (ie, a reduction in bacterial load of greater than 7 log(10) cfu) could be achieved if the needle guide was removed from the probe. However, if the needle guide was left in the probe channel during immersion in 2% glutaraldehyde, disinfection was not achieved (ie, the reduction was approximately 1 log(10) cfu). Recommendations for probe disinfection are provided and include disassembling the device and immersing the probe and the needle guide separately in a high-level disinfectant.
Efficacy of ultrasound-guided percutaneous needle treatment of calcific tendinitis.
Vignesh, K Nithin; McDowall, Adam; Simunovic, Nicole; Bhandari, Mohit; Choudur, Hema N
2015-01-01
The purpose of this study was to conduct a systematic review of the efficacy of ultrasound-guided needle lavage in treating calcific tendinitis. Two independent assessors searched medical databases and screened studies for eligibility. Eleven articles were included. Heterogeneity among included studies precluded meta-analysis. Results of randomized controlled trials suggested no difference in pain relief between needle lavage and other interventions, but the studies were of low quality. Additional high-quality evidence is required to determine the relative efficacy of ultrasound-guided needle lavage in the management of calcific tendinitis of the rotator cuff.
Bronchoscopic modalities to diagnose sarcoidosis.
Benzaquen, Sadia; Aragaki-Nakahodo, Alejandro Adolfo
2017-09-01
Several studies have investigated different bronchoscopic techniques to obtain tissue diagnosis in patients with suspected sarcoidosis when the diagnosis cannot be based on clinicoradiographic findings alone. In this review, we will describe the most recent and relevant evidence from different bronchoscopic modalities to diagnose sarcoidosis. Despite multiple available bronchoscopic modalities to procure tissue samples to diagnose sarcoidosis, the vast majority of evidence favors endobronchial ultrasound transbronchial needle aspiration to diagnose Scadding stages 1 and 2 sarcoidosis. Transbronchial lung cryobiopsy is a new technique that is mainly used to aid in the diagnosis of undifferentiated interstitial lung disease; however, we will discuss its potential use in sarcoidosis. This review illustrates the limited information about the different bronchoscopic techniques to aid in the diagnosis of pulmonary sarcoidosis. However, it demonstrates that the combination of available bronchoscopic techniques increases the diagnostic yield for suspected sarcoidosis.
Evaluation of the eZono 4000 with eZGuide for ultrasound-guided procedures.
Gadsden, Jeff; Latmore, Malikah; Levine, Daniel M
2015-05-01
Ultrasound-guided procedures are increasingly common in a variety of acute care settings, such as the operating room, critical care unit and emergency room. However, accurate judgment of needle tip position using traditional ultrasound technology is frequently difficult, and serious injury can result from inadvertently advancing beyond or through the target. Needle navigation is a recent innovation that allows the clinician to visualize the needle position and trajectory in real time as it approaches the target. A novel ultrasound machine has recently been introduced that is portable and designed for procedural guidance. The eZono 4000™ features an innovative needle navigation technology that is simple to use and permits the use of a wide range of commercially available needles, avoiding the inconvenience and cost of proprietary equipment. This article discusses this new ultrasound machine in the context of other currently available ultrasound machines featuring needle navigation.
Menacé, Cécilia; Choquet, Olivier; Abbal, Bertrand; Bringuier, Sophie; Capdevila, Xavier
2017-04-01
The real-time ultrasound-guided paramedian sagittal oblique approach for neuraxial blockade is technically demanding. Innovative technologies have been developed to improve nerve identification and the accuracy of needle placement. The aim of this study was to evaluate three types of ultrasound scans during ultrasound-guided epidural lumbar punctures in a spine phantom. Eleven sets of 20 ultrasound-guided epidural punctures were performed with 2D, GPS, and multiplanar ultrasound machines (660 punctures) on a spine phantom using an in-plane approach. For all punctures, execution time, number of attempts, bone contacts, and needle redirections were noted by an independent physician. Operator comfort and visibility of the needle (tip and shaft) were measured using a numerical scale. The use of GPS significantly decreased the number of punctures, needle repositionings, and bone contacts. Comfort of the physician was also significantly improved with the GPS system compared with the 2D and multiplanar systems. With the multiplanar system, the procedure was not facilitated and execution time was longer compared with 2D imaging after Bonferroni correction but interaction between the type of ultrasound system and mean execution time was not significant in a linear mixed model. There were no significant differences regarding needle tip and shaft visibility between the systems. Multiplanar and GPS needle-tracking systems do not reduce execution time compared with 2D imaging using a real-time ultrasound-guided paramedian sagittal oblique approach in spine phantoms. The GPS needle-tracking system can improve performance in terms of operator comfort, the number of attempts, needle redirections and bone contacts. Copyright © 2016 Société française d'anesthésie et de réanimation (Sfar). Published by Elsevier Masson SAS. All rights reserved.
Brief reports: regional anesthesia needles can introduce ultrasound gel into tissues.
Belavy, David
2010-09-01
Anesthesiologists may insert needles through ultrasound gel when performing ultrasound-guided regional anesthesia. In this study, it was determined whether needles carry gel into tissues. Ultrasound gel dyed blue was applied to pork rashers. Tuohy and short-bevel needles were passed through the gel and pork. The needles were then assessed for the presence of ultrasound gel. All needles, including those with stylets, carried gel and tissue within the lumen. Ultrasound gel may be injected around (and perhaps in) nerves during regional anesthesia procedures. Studies are needed to determine the implications of this practice.
Ultrasonography in Acupuncture-Uses in Education and Research.
Leow, Mabel Qi He; Cui, Shu Li; Mohamed Shah, Mohammad Taufik Bin; Cao, Taige; Tay, Shian Chao; Tay, Peter Kay Chai; Ooi, Chin Chin
2017-06-01
This study aims to explore the potential use of ultrasound in locating the second posterior sacral foramen acupuncture point, quantifying depth of insertion and describing surrounding anatomical structures. We performed acupuncture needle insertion on a study team member. There were four steps in our experiment. First, the acupuncturist located the acupuncture point by palpation. Second, we used an ultrasound machine to visualize the structures surrounding the location of the acupuncture point and measure the depth required for needle insertion. Third, the acupuncturist inserted the acupuncture needle into the acupuncture point at an angle of 30°. Fourth, we performed another ultrasound scan to ensure that the needle was in the desired location. Results suggested that ultrasound could be used to locate the acupuncture point and estimate the depth of needle insertion. The needle was inserted to a depth of 4.0 cm to reach the surface of the sacral foramen. Based on Pythagoras theorem, taking a needle insertion angle of 30° and a needle insertion depth of 4.0 cm, the estimated perpendicular depth is 1.8 cm. An ultrasound scan corroborated the depth of 1.85 cm. The use of an ultrasound-guided technique for needle insertion in acupuncture practice could help standardize the treatment. Clinicians and students would be able to visualize and measure the depth of the sacral foramen acupuncture point, to guide the depth of needle insertion. This methodological guide could also be used to create a standard treatment protocol for research. A similar mathematical guide could also be created for other acupuncture points in future. Copyright © 2017. Published by Elsevier B.V.
Accuracy of ultrasound-guided nerve blocks of the cervical zygapophysial joints.
Siegenthaler, Andreas; Mlekusch, Sabine; Trelle, Sven; Schliessbach, Juerg; Curatolo, Michele; Eichenberger, Urs
2012-08-01
Cervical zygapophysial joint nerve blocks typically are performed with fluoroscopic needle guidance. Descriptions of ultrasound-guided block of these nerves are available, but only one small study compared ultrasound with fluoroscopy, and only for the third occipital nerve. To evaluate the potential usefulness of ultrasound-guidance in clinical practice, studies that determine the accuracy of this technique using a validated control are essential. The aim of this study was to determine the accuracy of ultrasound-guided nerve blocks of the cervical zygapophysial joints using fluoroscopy as control. Sixty volunteers were studied. Ultrasound-imaging was used to place the needle to the bony target of cervical zygapophysial joint nerve blocks. The levels of needle placement were determined randomly (three levels per volunteer). After ultrasound-guided needle placement and application of 0.2 ml contrast dye, fluoroscopic imaging was performed for later evaluation by a blinded pain physician and considered as gold standard. Raw agreement, chance-corrected agreement κ, and chance-independent agreement Φ between the ultrasound-guided placement and the assessment using fluoroscopy were calculated to quantify accuracy. One hundred eighty needles were placed in 60 volunteers. Raw agreement was 87% (95% CI 81-91%), κ was 0.74 (0.64-0.83), and Φ 0.99 (0.99-0.99). Accuracy varied significantly between the different cervical nerves: it was low for the C7 medial branch, whereas all other levels showed very good accuracy. Ultrasound-imaging is an accurate technique for performing cervical zygapophysial joint nerve blocks in volunteers, except for the medial branch blocks of C7.
Niazi, A U; Chin, K J; Jin, R; Chan, V W
2014-08-01
Real-time ultrasound-guided neuraxial blockade remains a largely experimental technique. SonixGPS® is a new needle tracking system that displays needle tip position on the ultrasound screen. We investigated if this novel technology might aid performance of real-time ultrasound-guided spinal anesthesia. Twenty patients with body mass index < 35 kg/m(2) undergoing elective total joint arthroplasty under spinal anesthesia were recruited. Patients with previous back surgery and spinal abnormalities were excluded. Following a pre-procedural ultrasound scan, a 17G proprietary needle-sensor assembly was inserted in-plane to the transducer in four patients and out-of-plane in 16 patients. In both approaches, the trajectory of insertion was adjusted in real-time until the needle tip lay just superficial to the ligamentum flavum-dura mater complex. At this point, a 25G 120 mm Whitacre spinal needle was inserted through the 17G SonixGPS® needle. Successful dural puncture was confirmed by backflow of cerebrospinal fluid from the spinal needle. An overall success rate of 14/20 (70%) was seen with two failures (50%) and four failures (25%) in the in-plane and out-of-plane groups respectively. Dural puncture was successful on the first skin puncture in 71% of patients and in a single needle pass in 57% of patients. The median total procedure time was 16.4 and 11.1 min in the in-plane and out-of-plane groups respectively. The SonixGPS® system simplifies real-time ultrasound-guided spinal anesthesia to a large extent, especially the out-of-plane approach. Nevertheless, it remains a complex multi-step procedure that requires time, specialized equipment, and a working knowledge of spinal sonoanatomy. © 2014 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
Munoz, Mark L; Lechtzin, Noah; Li, Qing Kay; Wang, KoPen; Yarmus, Lonny B; Lee, Hans J; Feller-Kopman, David J
2017-07-01
In evaluating patients with suspected lung cancer, it is important to not only obtain a tissue diagnosis, but also to obtain enough tissue for both histologic and molecular analysis in order to appropriately stage the patient with a safe and efficient strategy. The diagnostic approach may often be dependent on local resources and practice patterns rather than current guidelines. We Describe lung cancer staging at two large academic medical centers to identify the impact different procedural approaches have on patient outcomes. We conducted a retrospective cohort study of all patients undergoing a lung cancer diagnostic evaluation at two multidisciplinary centers during a 1-year period. Identifying complication rates and the need for multiple biopsies as our primary outcomes, we developed a multivariate regression model to determine features associated with complications and need for multiple biopsies. Of 830 patients, 285 patients were diagnosed with lung cancers during the study period. Those staged at the institution without an endobronchial ultrasound (EBUS) program were more likely to require multiple biopsies (OR 3.62, 95% CI: 1.71-7.67, P=0.001) and suffer complications associated with the diagnostic procedure (OR 10.2, 95% CI: 3.08-33.58, P<0.001). Initial staging with transthoracic needle aspiration (TTNA) and conventional bronchoscopy were associated with greater need for subsequent biopsies (OR 8.05 and 14.00, 95% CI: 3.43-18.87 and 5.17-37.86, respectively) and higher complication rates (OR 37.75 and 7.20, 95% CI: 10.33-137.96 and 1.36-37.98, respectively). Lung cancer evaluation at centers with a dedicated EBUS program results in fewer biopsies and complications than at multidisciplinary counterparts without an EBUS program.
Fredrickson, Michael J
2008-01-01
Neurostimulation during single shot interscalene block has a significant false negative motor response rate. Compared with tangential needle approaches for single shot block, interscalene catheter (ISC) placement commonly involves Tuohy needles inserted longitudinally to the brachial plexus. This study aimed to determine the sensitivity of neurostimulation during ultrasound-guided ISC needle placement, and the feasibility of an ultrasound-guided ISC needle endpoint. One hundred fifty-five consecutive nonstimulating ISCs were placed with the needle tip position confirmed by the sonographic spread of 5 mL dextrose 5%. Catheter advancement was then blind 2 to 3 cm past the needle tip. A 0.8 mA electrical stimulus at 2 Hz was applied throughout. When a satisfactory image was obtained, neurostimulation was ignored and the minimum motor response amplitude noted. If imaging was equivocal, a brief appropriate motor response at 0.8 mA was sought. A sustained response at <0.5 mA was only sought if imaging was suboptimal. Prior to surgery conducted under general anesthesia, 30 mL ropivacaine 0.5% was administered through the ISC. Catheter success was defined as a recovery room numerical rating pain score of =2 (scale, 0-10). In 57% of patients, a muscle response was not elicited. An ultrasound needle endpoint was used in 92% of ISC placements, of which 96% were successful. Sustained twitches at <0.5 mA were obtained in 12 (8%) patients, 6 (4%) of these deliberately sought because of suboptimal imaging. Catheter success overall was 95%. This study suggests that the false negative motor response rate for longitudinal ISC needle placement is higher than the false negative response rate associated with tangential needle approach interscalene block. An ultrasound guided ISC needle endpoint is a feasible alternative to a neurostimulation endpoint.
da Costa, Ronaldo C.; Parent, Joane M.; Dobson, Howard; Ruotsalo, Kristiina; Holmberg, David; Duque, M. Carolina; Poma, Roberto
2008-01-01
Ultrasound-guided fine needle aspiration was used in establishing the diagnosis in 4 cases of malignant peripheral nerve sheath tumor. Sonographic and cytologic characteristics are discussed. Because of its availability and ease of use, axillary ultrasonography with fine needle aspiration can be an initial diagnostic step for suspected brachial plexus tumors. PMID:18320983
The role of endobronchial ultrasound versus mediastinoscopy for non-small cell lung cancer.
Czarnecka-Kujawa, Katarzyna; Yasufuku, Kazuhiro
2017-03-01
This review provides an update on the current role of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) and mediastinoscopy (Med) in assessment of patients with non-small cell lung cancer (NSCLC). Invasive mediastinal lymph node (LN) staging is the major application for both of these techniques. Up until recently, Med was the gold standard for invasive mediastinal LN staging in NSCLC. However, EBUS-TBNA has shown to be equivalent, and in some studies better than Med for invasive staging of lung cancer. EBUS-TBNA offers access to N1 LNs and development of the thin convex probe EBUS (TCP-EBUS) will expand EBUS-TBNA access from the paratracheal region and central airways to more distal parabronchial regions allowing for more extensive N1 LN assessment and sampling more distal lung tumors. EBUS-TBNA is more cost-effective than Med and it is currently recommended as the test of first choice for invasive mediastinal LN staging in lung cancer. Confirmatory Med should be performed selectively in patients with high pretest probability of metastatic disease. Addition of esophageal ultrasound fine needle aspiration (EUS-FNA) may increase diagnostic yield of EBUS-TBNA mediastinal staging. Both Med and EBUS-TBNA can be used in primary lung cancer diagnosis, restaging of the mediastinum following neoadjuvant therapy and in diagnosis of lung cancer recurrence. In the future, a combination of EBUS-TBNA with or without EUS-FNA and Med is most likely going to provide the most optimal invasive assessment of the mediastinum in patients with lung cancer. The decision on test choice and sequence should be made on a case-by-case basis and factoring in local resources and expertise.
Chu, Carissa; Masic, Selma; Usawachintachit, Manint; Hu, Weiguo; Yang, Wenzeng; Stoller, Marshall; Li, Jianxing
2016-01-01
Abstract Ultrasound-guided renal access for percutaneous nephrolithotomy (PCNL) is a safe, effective, and low-cost procedure commonly performed worldwide, but a technique underutilized by urologists in the United States. The purpose of this article is to familiarize the practicing urologist with methods for ultrasound guidance for percutaneous renal access. We discuss two alternative techniques for gaining renal access for PCNL under ultrasound guidance. We also describe a novel technique of using the puncture needle to reposition residual stone fragments to avoid additional tract dilation. With appropriate training, ultrasound-guided renal access for PCNL can lead to reduced radiation exposure, accurate renal access, and excellent stone-free success rates and clinical outcomes. PMID:26414304
NASA Astrophysics Data System (ADS)
Kim, Younsu; Kim, Sungmin; Boctor, Emad M.
2017-03-01
An ultrasound image-guided needle tracking systems have been widely used due to their cost-effectiveness and nonionizing radiation properties. Various surgical navigation systems have been developed by utilizing state-of-the-art sensor technologies. However, ultrasound transmission beam thickness causes unfair initial evaluation conditions due to inconsistent placement of the target with respect to the ultrasound probe. This inconsistency also brings high uncertainty and results in large standard deviations for each measurement when we compare accuracy with and without the guidance. To resolve this problem, we designed a complete evaluation platform by utilizing our mid-plane detection and time of flight measurement systems. The evaluating system uses a PZT element target and an ultrasound transmitting needle. In this paper, we evaluated an optical tracker-based surgical ultrasound-guided navigation system whereby the optical tracker tracks marker frames attached on the ultrasound probe and the needle. We performed ten needle trials of guidance experiment with a mid-plane adjustment algorithm and with a B-mode segmentation method. With the midplane adjustment, the result showed a mean error of 1.62+/-0.72mm. The mean error increased to 3.58+/-2.07mm without the mid-plane adjustment. Our evaluation system can reduce the effect of the beam-thickness problem, and measure ultrasound image-guided technologies consistently with a minimal standard deviation. Using our novel evaluation system, ultrasound image-guided technologies can be compared under equal initial conditions. Therefore, the error can be evaluated more accurately, and the system provides better analysis on the error sources such as ultrasound beam thickness.
Feasibility of Prostate Cancer Diagnosis by Transrectal Photo-acoustic Imaging
2013-03-01
prostate. Transrectal ultrasound has been used as a guiding tool to direct tissue needle biopsy for prostate cancer diagnosis; it cannot be utilized for...tool currently available for prostate cancer detection; needle biopsy is the current practice for diagnosis of the disease, aiming randomly in the...developing an integrated approach between ultrasound and optical tomography, namely, transrectal ultrasound - guided diffuse optical tomography (TRUS
Improving needle tip identification during ultrasound-guided procedures in anaesthetic practice.
Scholten, H J; Pourtaherian, A; Mihajlovic, N; Korsten, H H M; A Bouwman, R
2017-07-01
Ultrasound guidance is becoming standard practice for needle-based interventions in anaesthetic practice, such as vascular access and peripheral nerve blocks. However, difficulties in aligning the needle and the transducer can lead to incorrect identification of the needle tip, possibly damaging structures not visible on the ultrasound screen. Additional techniques specifically developed to aid alignment of needle and probe or identification of the needle tip are now available. In this scoping review, advantages and limitations of the following categories of those solutions are presented: needle guides; alterations to needle or needle tip; three- and four-dimensional ultrasound; magnetism, electromagnetic or GPS systems; optical tracking; augmented (virtual) reality; robotic assistance; and automated (computerised) needle detection. Most evidence originates from phantom studies, case reports and series, with few randomised clinical trials. Improved first-pass success and reduced performance time are the most frequently cited benefits, whereas the need for additional and often expensive hardware is the greatest limitation to widespread adoption. Novice ultrasound users seem to benefit most and great potential lies in education. Future research should focus on reporting relevant clinical parameters to learn which technique will benefit patients most in terms of success and safety. © 2017 The Association of Anaesthetists of Great Britain and Ireland.
An ultrasound needle insertion guide in a porcine phantom model.
Whittaker, S; Lethbridge, G; Kim, C; Keon Cohen, Z; Ng, I
2013-08-01
We compared nerve blockade with and without the Infiniti(TM) needle guide in an ultrasound in-plane porcine simulation. We recruited 30 anaesthetists with varying blockade experience. Using the guide, the needle tip was more visible (for a median (IQR [range]) of 67 (56-100]) % of the time; and invisible for 2 (1-4 [0-19]) s) than when the guide was not used (respectively 23 (13-43 [0-80]) % and 25 (9-52 [1-198]) s; both p < 0.001). The corresponding block times were 8 (6-10 [3-28]) s and 32 (15-67 [5-225]) s, respectively; p < 0.001. The needle guide reduced the block time and the time that the needle was invisible, irrespective of anaesthetist experience. Anaesthesia © 2013 The Association of Anaesthetists of Great Britain and Ireland.
Assistive technology for ultrasound-guided central venous catheter placement.
Ikhsan, Mohammad; Tan, Kok Kiong; Putra, Andi Sudjana
2018-01-01
This study evaluated the existing technology used to improve the safety and ease of ultrasound-guided central venous catheterization. Electronic database searches were conducted in Scopus, IEEE, Google Patents, and relevant conference databases (SPIE, MICCAI, and IEEE conferences) for related articles on assistive technology for ultrasound-guided central venous catheterization. A total of 89 articles were examined and pointed to several fields that are currently the focus of improvements to ultrasound-guided procedures. These include improving needle visualization, needle guides and localization technology, image processing algorithms to enhance and segment important features within the ultrasound image, robotic assistance using probe-mounted manipulators, and improving procedure ergonomics through in situ projections of important information. Probe-mounted robotic manipulators provide a promising avenue for assistive technology developed for freehand ultrasound-guided percutaneous procedures. However, there is currently a lack of clinical trials to validate the effectiveness of these devices.
Molecular Endoscopic Ultrasound for Diagnosis of Pancreatic Cancer
Bournet, Barbara; Pointreau, Adeline; Delpu, Yannick; Selves, Janick; Torrisani, Jerome; Buscail, Louis; Cordelier, Pierre
2011-01-01
Endoscopic ultrasound-guided fine needle aspiration-biopsy is a safe and effective technique in diagnosing and staging of pancreatic ductal adenocarcinoma. However its predictive negative value does not exceed 50% to 60%. Unfortunately, the majority of pancreatic cancer patients have a metastatic and/or a locally advanced disease (i.e., not eligible for curative resection) which explains the limited access to pancreatic tissue specimens. Endoscopic ultrasound-guided fine needle aspiration-biopsy is the most widely used approach for cytological and histological material sampling in these situations used in up to two thirds of patients with pancreatic cancer. Based on this unique material, we and others developed strategies to improve the differential diagnosis between carcinoma and inflammatory pancreatic lesions by analysis of KRAS oncogene mutation, microRNA expression and methylation, as well as mRNA expression using both qRT-PCR and Low Density Array Taqman analysis. Indeed, differentiating pancreatic cancer from pseudotumoral chronic pancreatitis remains very difficult in current clinical practice, and endoscopic ultrasound-guided fine needle aspiration-biopsy analysis proved to be very helpful. In this review, we will compile the clinical and molecular advantages of using endoscopic ultrasound-guided fine needle aspiration-biopsy in managing pancreatic cancer. PMID:24212643
Salemis, Nikolaos S; Vasilara, Georgia; Lagoudianakis, Emmanuel
2015-01-01
Mondor's disease is a rare benign and self-limiting condition characterized by thrombophlebitis of the superficial veins of the anterolateral thoracoabdominal wall. We describe a case of Mondor's disease of the breast as a complication of an ultrasound-guided core needle biospy. The patient presented with a palpable cord-like structure in her left breast, associated with severe pain and tenderness. She was treated concervatively and complete resolution was observed after four weeks. We conclude that emergency clinicians and interventional breast radiologists should be aware of Mondor's disease as a potential complication of ultrasound-guided core needle biopsy of the breast.
Ultrasound-guided synovial biopsy
Sitt, Jacqueline C M; Wong, Priscilla
2016-01-01
Ultrasound-guided needle biopsy of synovium is an increasingly performed procedure with a high diagnostic yield. In this review, we discuss the normal synovium, as well as the indications, technique, tissue handling and clinical applications of ultrasound-guided synovial biopsy. PMID:26581578
MLESAC Based Localization of Needle Insertion Using 2D Ultrasound Images
NASA Astrophysics Data System (ADS)
Xu, Fei; Gao, Dedong; Wang, Shan; Zhanwen, A.
2018-04-01
In the 2D ultrasound image of ultrasound-guided percutaneous needle insertions, it is difficult to determine the positions of needle axis and tip because of the existence of artifacts and other noises. In this work the speckle is regarded as the noise of an ultrasound image, and a novel algorithm is presented to detect the needle in a 2D ultrasound image. Firstly, the wavelet soft thresholding technique based on BayesShrink rule is used to denoise the speckle of ultrasound image. Secondly, we add Otsu’s thresholding method and morphologic operations to pre-process the ultrasound image. Finally, the localization of the needle is identified and positioned in the 2D ultrasound image based on the maximum likelihood estimation sample consensus (MLESAC) algorithm. The experimental results show that it is valid for estimating the position of needle axis and tip in the ultrasound images with the proposed algorithm. The research work is hopeful to be used in the path planning and robot-assisted needle insertion procedures.
Goyal, Abhishek; Gupta, Dheeraj; Agarwal, Ritesh; Bal, Amanjit; Nijhawan, Raje; Aggarwal, Ashutosh N
2014-07-01
The exact position of routine bronchoscopic sampling techniques in diagnostic workup of sarcoidosis is often debated. Herein, we ascertain the role of transbronchial needle aspiration (TBNA), endobronchial ultrasound-guided TBNA (EBUS-TBNA), transbronchial lung biopsy (TBLB), and endobronchial biopsy (EBB) in diagnosis of sarcoidosis. Consecutive patients with suspected sarcoidosis who underwent fiberoptic bronchoscopy were studied. TBLB, EBB, TBNA, or EBUS-TBNA was performed as indicated in a standardized manner. A diagnosis of sarcoidosis was established based on the finding of non-necrotizing granulomas or on clinical grounds at 6-month follow-up. Individual and cumulative yield of various procedures and their correlation with clinicoradiologic parameters was analyzed. Of the 164 patients studied, 151 were finally diagnosed as sarcoidosis. Granulomas were demonstrated in 127 (84.2%) patients. Diagnostic yield of TBLB, EBB, TBNA, and EBUS-TBNA was 68.7%, 49.6%, 22.43%, and 57.1%, respectively. Cumulative yields of various procedures were: EBB+TBLB 81.4%; TBLB+TBNA 73.7%; TBNA+EBB 62.9%; TBLB+EBB+TBNA 86.9%; and TBLB+EBB+EBUS-TBNA 86.4%. In those with visible mucosal abnormalities, TBLB+EBB conferred the highest diagnostic yield (92.8%). Clinical findings or radiologic stage had no impact on diagnostic yield. TBLB is an important tool in bronchoscopic diagnosis of sarcoidosis. If endobronchial abnormalities are seen during bronchoscopy, TBLB with EBB gives the best results otherwise TBLB combined with conventional TBNA and EBB or EBUS-TBNA are required to maximize the diagnostic yield.
Analysis of "dry" mesothelioma with ultrasound guided biopsies.
Stigt, Jos A; Boers, James E; Groen, Harry J M
2012-12-01
Image-guided sampling of the thickened pleura is a sensitive approach in patients with malignant pleural mesothelioma with pleural effusion. Malignant pleural mesothelioma presenting without effusion however is more of a diagnostic challenge. In this study we report the diagnostic yield and complications of ultrasound-guided cutting needle biopsies in this particular category of patients. A retrospective database analysis from September 2007 until January 2012 was performed in 56 patients with malignant pleural mesothelioma. Clinical characteristics and results of diagnostic evaluations were analysed. Of the 56 patients with malignant pleural mesothelioma, 20 patients presented without pleural effusion of with locular effusion. Ultrasound-guided cutting needle biopsy was performed in 14/20 patients with a diagnostic accuracy of 80%. Only 1 patient had mild haemoptysis immediately following biopsies. Diagnosing patients with pleural thickenings suspect for malignant mesothelioma without pleural effusion or with loculated pleural effusion is effective and safe with ultrasound-guided cutting needle biopsies. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Needle tip visibility in 3D ultrasound images
NASA Astrophysics Data System (ADS)
Arif, Muhammad; Moelker, Adriaan; van Walsum, Theo
2017-03-01
Needle visibility is of crucial importance for ultrasound guided interventional procedures. However, several factors, such as shadowing by bone or gas and tissue echogenic properties similar to needles, may compromise needle visibility. Additionally, small angle between the ultrasound beam and the needle, as well as small gauged needles may reduce visibility. Variety in needle tips design may also affect needle visibility. Whereas several studies have investigated needle visibility in 2D ultrasound imaging, no data is available for 3D ultrasound imaging, a modality that has great potential for image guidance interventions1. In this study, we evaluated needle visibility using a 3D ultrasound transducer. We examined different needles in a tissue mimicking liver phantom at three angles (200, 550 and 900) and quantify their visibility. The liver phantom was made by 5% polyvinyl alcohol solution containing 1% Silica gel particles to act as ultrasound scattering particles. We used four needles; two biopsy needles (Quick core 14G and 18G), one Ablation needle (Radiofrequency Ablation 17G), and Initial puncture needle (IP needle 17G). The needle visibility was quantified by calculating contrast to noise ratio. The results showed that the visibility for all needles were almost similar at large angles. However the difference in visibility at lower angles is more prominent. Furthermore, the visibility increases with the increase in angle of ultrasound beam with needles.
Electromagnetic-Tracked Biopsy under Ultrasound Guidance: Preliminary Results
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hakime, Antoine, E-mail: thakime@yahoo.com; Deschamps, Frederic; Marques De Carvalho, Enio Garcia
2012-08-15
Purpose: This study was designed to evaluate the accuracy and safety of electromagnetic needle tracking for sonographically guided percutaneous liver biopsies. Methods: We performed 23 consecutive ultrasound-guided liver biopsies for liver nodules with an electromagnetic tracking of the needle. A sensor placed at the tip of a sterile stylet (18G) inserted in a coaxial guiding trocar (16G) used for biopsy was localized in real time relative to the ultrasound imaging plane, thanks to an electromagnetic transmitter and two sensors on the ultrasound probe. This allows for electronic display of the needle tip location and the future needle path overlaid onmore » the real-time ultrasound image. Distance between needle tip position and its electronic display, number of needle punctures, number of needle pull backs for redirection, technical success (needle positioned in the target), diagnostic success (correct histopathology result), procedure time, and complication were evaluated according to lesion sizes, depth and location, operator experience, and 'in-plane' or 'out-of-plane' needle approach. Results: Electronic display was always within 2 mm from the real position of the needle tip. The technical success rate was 100%. A single needle puncture without repuncture was used in all patients. Pull backs were necessary in six patients (26%) to obtain correct needle placement. The overall diagnostic success rate was 91%. The overall true-positive, true-negative, false-negative, and failure rates of the biopsy were 100% (19/19) 100% (2/2), 0% (0/23), and 9% (2/23). The median total procedure time from the skin puncture to the needle in the target was 30 sec (from 5-60 s). Lesion depth and localizations, operator experience, in-plane or out-of-plane approach did not affect significantly the technical, diagnostic success, or procedure time. Even when the tumor size decreased, the procedure time did not increase. Conclusions: Electromagnetic-tracked biopsy is accurate to determine needle tip position and allows fast and accurate needle placement in targeted liver nodules.« less
Lieu, David
2009-04-01
Fine-needle aspiration (FNA) of breast masses in the United States has been on the decline for the last decade and has been largely replaced by ultrasound-guided core-needle biopsy (UG-CNB). Some studies show core-needle biopsy (CNB) is superior to FNA in terms of absolute sensitivity, specificity, and inadequate rate. However, the importance of a skilled aspirator, experienced cytopathologist, and immediate cytological evaluation (ICE) in FNA is often not considered. CNB is more expensive, invasive, risky, and painful than FNA. This prospective study examines the value of cytopathologist-performed ultrasound-guided FNA (UG-FNA) with ICE as a screening test for cytopathologist-performed UG-CNB on nonpalpable or difficult-to-palpate solid breast masses visible on ultrasound. One hundred twenty consecutive nonpalpable or difficult-to-palpate presumably solid breast masses in 109 female patients from January2, 2008 to June 30, 2008 underwent cytopathologist-performed UG-FNA with ICE. Twenty cases were converted to cytopathologist-performed UG-CNB because ICE was inadequate, hypocellular, atypical, suspicious, or malignant. Patients with clearly benign cytology did not undergo UG-CNB. UG-FNA with ICE reduced the percentage of patients undergoing UG-CNB by 87%. A new role for cytopathologist-performed UG-FNA of nonpalpable breast masses has been identified.
Feeney, Daniel A; Ober, Christopher P; Snyder, Laura A; Hill, Sara A; Jessen, Carl R
2013-01-01
Peritoneal, mesenteric, and omental diseases are important causes of morbidity and mortality in humans and animals, although information in the veterinary literature is limited. The purposes of this retrospective study were to determine whether objectively applied ultrasound interpretive criteria are statistically useful in differentiating among cytologically defined normal, inflammatory, and neoplastic peritoneal conditions in dogs and cats. A second goal was to determine the cytologically interpretable yield on ultrasound-guided, fine-needle sampling of peritoneal, mesenteric, or omental structures. Sonographic criteria agreed upon by the authors were retrospectively and independently applied by two radiologists to the available ultrasound images without knowledge of the cytologic diagnosis and statistically compared to the ultrasound-guided, fine-needle aspiration cytologic interpretations. A total of 72 dogs and 49 cats with abdominal peritoneal, mesenteric, or omental (peritoneal) surface or effusive disease and 17 dogs and 3 cats with no cytologic evidence of inflammation or neoplasia were included. The optimized, ultrasound criteria-based statistical model created independently for each radiologist yielded an equation-based diagnostic category placement accuracy of 63.2-69.9% across the two involved radiologists. Regional organ-associated masses or nodules as well as aggregated bowel and peritoneal thickening were more associated with peritoneal neoplasia whereas localized, severely complex fluid collections were more associated with inflammatory peritoneal disease. The cytologically interpretable yield for ultrasound-guided fine-needle sampling was 72.3% with no difference between species, making this a worthwhile clinical procedure. © 2013 Veterinary Radiology & Ultrasound.
NASA Astrophysics Data System (ADS)
Susanti, Hesty; Suprijanto, Kurniadi, Deddy
2018-02-01
Needle visibility in ultrasound-guided technique has been a crucial factor for successful interventional procedure. It has been affected by several factors, i.e. puncture depth, insertion angle, needle size and material, and imaging technology. The influences of those factors made the needle not always well visible. 20 G needles of 15 cm length (Nano Line, facet) were inserted into water bath with variation of insertion angles and depths. Ultrasound measurements are performed with BK-Medical Flex Focus 800 using 12 MHz linear array and 5 MHz curved array in Ultrasound Guided Regional Anesthesia mode. We propose 3 criteria to evaluate needle visibility, i.e. maximum intensity, mean intensity, and the ratio between minimum and maximum intensity. Those criteria were then depicted into representative maps for practical purpose. The best criterion candidate for representing the needle visibility was criterion 1. Generally, the appearance pattern of the needle from this criterion was relatively consistent, i.e. for linear array, it was relatively poor visibility in the middle part of the shaft, while for curved array, it is relatively better visible toward the end of the shaft. With further investigations, for example with the use of tissue-mimicking phantom, the representative maps can be built for future practical purpose, i.e. as a tool for clinicians to ensure better needle placement in clinical application. It will help them to avoid the "dead" area where the needle is not well visible, so it can reduce the risks of vital structures traversing and the number of required insertion, resulting in less patient morbidity. Those simple criteria and representative maps can be utilized to evaluate general visibility patterns of the needle in vast range of needle types and sizes in different insertion media. This information is also important as an early investigation for future research of needle visibility improvement, i.e. the development of beamforming strategies and ultrasound enhanced (echogenic) needle.
New platform for evaluating ultrasound-guided interventional technologies
NASA Astrophysics Data System (ADS)
Kim, Younsu; Guo, Xiaoyu; Boctor, Emad M.
2016-04-01
Ultrasound-guided needle tracking systems are frequently used in surgical procedures. Various needle tracking technologies have been developed using ultrasound, electromagnetic sensors, and optical sensors. To evaluate these new needle tracking technologies, 3D volume information is often acquired to compute the actual distance from the needle tip to the target object. The image-guidance conditions for comparison are often inconsistent due to the ultrasound beam-thickness. Since 3D volumes are necessary, there is often some time delay between the surgical procedure and the evaluation. These evaluation methods will generally only measure the final needle location because they interrupt the surgical procedure. The main contribution of this work is a new platform for evaluating needle tracking systems in real-time, resolving the problems stated above. We developed new tools to evaluate the precise distance between the needle tip and the target object. A PZT element transmitting unit is designed as needle introducer shape so that it can be inserted in the needle. We have collected time of flight and amplitude information in real-time. We propose two systems to collect ultrasound signals. We demonstrate this platform on an ultrasound DAQ system and a cost-effective FPGA board. The results of a chicken breast experiment show the feasibility of tracking a time series of needle tip distances. We performed validation experiments with a plastisol phantom and have shown that the preliminary data fits a linear regression model with a RMSE of less than 0.6mm. Our platform can be applied to more general needle tracking methods using other forms of guidance.
Endoscopic ultrasound-guided fine-needle aspiration needles: which one and in what situation?
Karadsheh, Zeid; Al-Haddad, Mohammad
2014-01-01
Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) is increasingly used as a diagnostic and therapeutic tool for pancreatic and other gastrointestinal disorders. Several factors affect the outcome of EUS-FNA, one of which is needle size. The decision to use a specific needle depends on factors including location, consistency, and type of the lesion; presence of onsite cytopathologist; and need for additional tissue procurement for histology. This review provides a balanced perspective on the use of different needle sizes available, highlighting the differences among them and potential niche applications of each to maximize diagnostic yield of EUS-FNA. Copyright © 2014 Elsevier Inc. All rights reserved.
Ultrasound-guided suprascapular nerve block: a correlation with fluoroscopic and cadaveric findings.
Peng, Philip W H; Wiley, Michael J; Liang, James; Bellingham, Geoff A
2010-02-01
Previous work on the ultrasound-guided injection technique and the sonoanatomy of the suprascapular region relevant to the suprascapular nerve (SSN) block suggested that the ultrasound scan showed the presence of the suprascapular notch and transverse ligament. The intended target of the ultrasound-guided injection was the notch. The objective of this case report and the subsequent cadaver dissection findings is to reassess the interpretation of the ultrasound images when locating structures for SSN block. A 45-yr-old man with chronic shoulder pain received an ultrasound-guided SSN block using the suprascapular notch as the intended target. The position of the needle was verified by fluoroscopy, which showed the tip of the needle well outside the suprascapular notch. Similar ultrasound-guided SSN blocks were performed in two cadavers. Dissections were performed which showed that the needle tips were not at the suprascapular notch but, more accurately, were close to the SSN but at the floor of the suprascapular fossa between the suprascapular and spinoglenoid notch. Our fluoroscopic and cadaver dissection findings both suggest that the ultrasound image of the SSN block shown by the well-described technique is actually targeting the nerve on the floor of the suprascapular spine between the suprascapular and spinoglenoid notches rather than the suprascapular notch itself. The structure previously identified as the transverse ligament is actually the fascia layer of the supraspinatus muscle.
Simulation and training of ultrasound supported anaesthesia: a low-cost approach
NASA Astrophysics Data System (ADS)
Schaaf, T.; Lamontain, M.; Hilpert, J.; Schilling, F.; Tolxdorff, T.
2010-03-01
The use of ultrasound imaging technology during techniques of peripheral nerve blockade offers several clinical benefits. Here we report on a new method to educate residents in ultrasound-guided regional anesthesia. The daily challenge for the anesthesiologists is the 3D angle-depending handling of the stimulation needle and the ultrasound probe while watching the 2D ultrasound image on the monitor. Purpose: Our approach describes how a computer-aided simulation and training set for ultrasound-guided regional anesthesia could be built based on wireless low-cost devices and an interactive simulation of a 2D ultrasound image. For training purposes the injection needle and the ultrasound probe are replaced by wireless Bluetooth-connected 3D tracking devices, which are embedded in WII-mote controllers (Nintendo-Brand). In correlation to the tracked 3D positions of the needle and transducer models the visibility and position of the needle should be simulated in the 2D generated ultrasound image. Conclusion: In future, this tracking and visualization software module could be integrated in a more complex training set, where complex injection paths could be trained based on a 3D segmented model and the training results could be part of a curricular e-learning module.
Alsaeed, A; Thallaj, A; Alzahrani, T; Khalil, N; Aljazaeri, A
2014-10-01
The most common peripheral nerve blocks used in umbilical hernia repair are rectus sheath block and regional block (caudal block). Ultrasound guidance of peripheral nerve blocks has reduced the number of complications and improved the quality of blocks. The aim of this study is to assess the post rectus sheath block pain relief in pediatric patients coming for umbilical surgery, and to evaluate the easiness of soft tissue puncture and ultrasonic appearance of two different needle types. Twenty two (22) pediatric patients (age range: 1.5-8 years) scheduled for umbilical hernia repair were included in the study. Following the induction of general anesthesia, the ultrasonographic anatomy of the umbilical region was studied with a 5-16 MHz linear probe. An ultrasound-guided rectus sheath block in the lateral edge of both rectus abdominis muscles (RMs) was performed (total of 44 punctures). A 22 gauge short beveled sharp cutting needle 1.1 x 30 mm needle A (BD Insyte--W, Vialon material. Spain) was used in one side, and a Stimuplex A insulated Needle 22G 50mm (needle B) was used on the other side. Surgical conditions, intraoperative hemodynamic parameters, and postoperative analgesia were evaluated. Ultrasonograghic visualization of the posterior sheath was possible in all patients. Needle A scored 72.7% of excellent needle tip and shaft view (16 out of 22) compared to 63.63% for needle B (14 out of 22). None of the needles scored poor view. The ultrasound guided rectus sheath blockade provided sufficient analgesia in all children with no need for additional analgesia except for one child who postoperatively requested morphine 0.1 mg/kg intravenously in recovery room. There were no complications. Ultrasound guidance enables performances of an effective rectus sheath block for umbilical hernia in the lateral edge of the rectus muscle. Use of the sharp short beveled needle of 22 gauge intravenous (IV) cannula stylet provides easy, less traumatic skin and rectus muscle penetration and better needle visualization by the ultrasound.
Membrillo-Romero, Alejandro; Gonzalez-Lanzagorta, Rubén; Rascón-Martínez, Dulce María
Puncture biopsy and fine needle aspiration guided by endoscopic ultrasound has been used as an effective technique and is quickly becoming the procedure of choice for diagnosis and staging in patients suspected of having pancreatic cancer. This procedure has replaced retrograde cholangiopancreatography and brush cytology due to its higher sensitivity for diagnosis, and lower risk of complications. To assess the levels of pancreatic enzymes amylase and lipase, after the puncture biopsy and fine needle aspiration guided by endoscopic ultrasound in pancreatic lesions and the frequency of post-puncture acute pancreatitis. A longitudinal and descriptive study of consecutive cases was performed on outpatients submitted to puncture biopsy and fine needle aspiration guided by endoscopic ultrasound in pancreatic lesions. Levels of pancreatic enzymes such as amylase and lipase were measured before and after the pancreatic puncture. Finally we documented post-puncture pancreatitis cases. A total of 100 patients who had been diagnosed with solid and cystic lesions were included in the study. Significant elevation was found at twice the reference value for lipase in 5 cases (5%) and for amylase in 2 cases (2%), none had clinical symptoms of acute pancreatitis. Eight (8%) of patients presented with mild nonspecific pain with no enzyme elevation compatible with pancreatitis. Pancreatic biopsy needle aspiration guided by endoscopic ultrasound was associated with a low rate of elevated pancreatic enzymes and there were no cases of post-puncture pancreatitis. Copyright © 2016 Academia Mexicana de Cirugía A.C. Publicado por Masson Doyma México S.A. All rights reserved.
Lam, Nicholas C K; Fishburn, Steven J; Hammer, Angie R; Petersen, Timothy R; Gerstein, Neal S; Mariano, Edward R
2015-06-01
Achieving the best view of the needle and target anatomy when performing ultrasound-guided interventional procedures requires technical skill, which novices may find difficult to learn. We hypothesized that teaching novice performers to use 4 sequential steps (see, tilt, align, and rotate [STAR] method) to identify the needle under ultrasound guidance is more efficient than training with the commonly described probe movements of align, rotate, and tilt (ART). This study compared 2 instructional methods for transducer manipulation including alignment of a probe and needle by novices during a simulated ultrasound-guided nerve block. Right-handed volunteers between the ages of 18 and 55 years who had no previous ultrasound experience were recruited and randomized to 1 of 2 groups; one group was trained to troubleshoot misalignment with the ART method, and the other was trained with the new STAR maneuver. Participants performed the task, consisting of directing a needle in plane to 3 targets in a standardized gelatin phantom 3 times. The performance assessor and data analyst were blinded to group assignment. Thirty-five participants were recruited. The STAR group was able to complete the task more quickly (P < .001) and visualized the needle in a greater proportion of the procedure time (P = .004) compared to the ART group. All STAR participants were able to complete the task, whereas 41% of ART participants abandoned the task (P = .003). Novices are able to complete a simulated ultrasound-guided nerve block more quickly and efficiently when trained with the 4-step STAR maneuver compared to the ART method. © 2015 by the American Institute of Ultrasound in Medicine.
Ultrasound-guided needle EMG of the diaphragm: technique description and case report.
Boon, Andrea J; Alsharif, Kais I; Harper, C Michel; Smith, Jay
2008-12-01
We describe an ultrasound (US)-guided technique for needle examination of the diaphragm and report a case in which the adjuvant use of diagnostic US in conjunction with electrophysiologic studies provided additional information regarding the motion of the diaphragm in a patient who was a potential candidate for phrenic nerve pacing. US imaging provides excellent direct and real-time visualization of soft tissue, anatomic landmarks, fascial planes, and neurovascular structures. It thereby enhances safety by avoiding accidental needle puncture of vital organs, and it also increases the diagnostic utility of the needle examination.
ERIC Educational Resources Information Center
de Araújo Setin, Raíza; Fortes Cirimbelli, Carolina; Mazeto Ercolin, Anna Carolina; Pires, Sâmara Turbay; Disselli, Tamiris; Ferrarini Nunes Soares Hage, Maria Cristina
2018-01-01
The present study aimed to evaluate the applicability of artisanal simulators to teach veterinary and medical students the ultrasound-guided percutaneous biopsy using a tru-cut needle. The artisanal simulators consisted of bovine liver between two layers of commercially available grape gelatin. Students were paired, with one doing the biopsy and…
Learning Ultrasound-Guided Needle Insertion Skills through an Edutainment Game
NASA Astrophysics Data System (ADS)
Chan, Wing-Yin; Ni, Dong; Pang, Wai-Man; Qin, Jing; Chui, Yim-Pan; Yu, Simon Chun-Ho; Heng, Pheng-Ann
Ultrasound-guided needle insertion is essential in many of minimally invasive surgeries or procedures, such as biopsy, drug delivery, spinal anaesthesia, etc. Accurate and safe needle insertion is a difficult task due to the high requirement of hand-eye coordination skills. Many proposed virtual reality (VR) based training systems put their emphasis on realistic simulation instead of pedagogical efficiency. The lack of schematic training scenario leads to boredom of repetitive operations. To solve this, we present our novel training system with the integration of game elements in order to retain the trainees' enthusiasm. Task-oriented scenarios, time attack scenarios and performance evaluation are introduced. Besides, some state-of-art technologies are also presented, including ultrasound simulation, needle haptic rendering as well as a mass-spring-based needle-tissue interaction simulation. These works are shown to be effective to keep the trainees up with learning.
A review of the benefits and pitfalls of phantoms in ultrasound-guided regional anesthesia.
Hocking, Graham; Hebard, Simon; Mitchell, Christopher H
2011-01-01
With the growth of ultrasound-guided regional anesthesia, so has the requirement for training tools to practice needle guidance skills and evaluate echogenic needles. Ethically, skills in ultrasound-guided needle placement should be gained in a phantom before performance of nerve blocks on patients in clinical practice. However, phantom technology is varied, and critical evaluation of the images is needed to understand their application to clinical use. Needle visibility depends on the echogenicity of the needle relative to the echogenicity of the tissue adjacent the needle. We demonstrate this point using images of echogenic and nonechogenic needles in 5 different phantoms at both shallow angles (20 degrees) and steep angles (45 degrees). The echogenicity of phantoms varies enormously, and this impacts on how needles are visualized. Water is anechoic, making all needles highly visible, but does not fix the needle to allow practice placement. Gelatin phantoms and Blue Phantoms provide tactile feedback but have very low background echogenicity, which greatly exaggerates needle visibility. This makes skill acquisition easier but can lead to false confidence in regard to clinical ability. Fresh-frozen cadavers retain much of the textural feel of live human tissue and are nearly as echogenic. Similar to clinical practice, this makes needles inserted at steep angles practically invisible, unless they are highly echogenic. This review describes the uses and pitfalls of phantoms that have been described or commercially produced. Copyright © 2011 by American Society of Regional Anesthesia and Pain Medicine
Single-operator real-time ultrasound-guided spinal injection using SonixGPS™: a case series.
Brinkmann, Silke; Tang, Raymond; Sawka, Andrew; Vaghadia, Himat
2013-09-01
The SonixGPS™ is a novel needle tracking system that has recently been approved in Canada for ultrasound-guided needle interventions. It allows optimization of needle-beam alignment by providing a real-time display of current and predicted needle tip position. Currently, there is limited evidence on the effectiveness of this technique for performance of real-time spinal anesthesia. This case series reports performance of the SonixGPS system for real-time ultrasound-guided spinal anesthesia in elective patients scheduled for joint arthroplasty. In this single-centre case series, 20 American Society of Anesthesiologists' class I-II patients scheduled for lower limb joint arthroplasty were recruited to undergo real-time ultrasound-guided spinal anesthesia with the SonixGPS after written informed consent. The primary outcome for this clinical cases series was the success rate of spinal anesthesia, and the main secondary outcome was time required to perform spinal anesthesia. Successful spinal anesthesia for joint arthroplasty was achieved in 18/20 patients, and 17 of these required only a single skin puncture. In 7/20 (35%) patients, dural puncture was achieved on the first needle pass, and in 11/20 (55%) patients, dural puncture was achieved with two or three needle redirections. Median (range) time taken to perform the block was 8 (5-14) min. The study procedure was aborted in two cases because our clinical protocol dictated using a standard approach if spinal anesthesia was unsuccessful after three ultrasound-guided insertion attempts. These two cases were classified as failures. No complications, including paresthesia, were observed during the procedure. All patients with successful spinal anesthesia found the technique acceptable and were willing to undergo a repeat procedure if deemed necessary. This case series shows that real-time ultrasound-guided spinal anesthesia with the SonixGPS system is possible within an acceptable time frame. It proved effective with a low rate of failure and a low rate of complications. Our clinical experience suggests that a randomized trial is warranted to compare the SonixGPS with a standard block technique.
Ultrasound-guided percutaneous fine-needle aspiration of 545 focal pancreatic lesions.
Zamboni, Giulia A; D'Onofrio, Mirko; Idili, Antonio; Malagò, Roberto; Iozzia, Roberta; Manfrin, Erminia; Mucelli, Roberto Pozzi
2009-12-01
The purpose of this study was to assess the accuracy and short-term complication rate of ultrasound-guided fine-needle aspiration cytologic sampling of focal pancreatic lesions. We reviewed 545 consecutive ultrasound-guided fine-needle aspiration cytologic sampling procedures for focal pancreatic lesions from January 2004 through June 2008. The procedures were performed with a 20- or 21-gauge needle. The onsite cytopathologist evaluated the appropriateness of the sample and made a diagnosis. We reviewed the final diagnosis and the radiologic and medical records of all patients for onset of complications during or within 7 days of the procedure. The study sample included 262 women and 283 men (mean age, 62 years; range, 25-86 years). The head or uncinate process of the pancreas was the location of 63.0% of the lesions, and 35.2% of the lesions were located in the body or tail of the pancreas. The site of 10 lesions (1.8%) was not specified. Sampling was diagnostic in 509 of the 545 cases (93.4%). Excluding the 36 nondiagnostic samples, ultrasound-guided fine-needle aspiration cytologic sampling had 99.4% sensitivity, 100% specificity, and 99.4% accuracy. In 537 of the 545 cases (98.5%), the procedure was uneventful. In two cases, abdominal fluid was found after the procedure that was not present before the procedure. Six patients experienced postprocedural pain without abnormal findings at subsequent imaging. No major complications occurred. Ultrasound-guided cytologic sampling is safe and accurate for the diagnosis and planning of management of focal pancreatic lesions. With a cytologist on site, the rate of acquisition of samples adequate for diagnosis is high, reducing the need for patient recall.
Grady, Ian; Vasquez, Tony; Tawfik, Sara; Grady, Sean
2017-03-01
To evaluate the cost-efficacy of vacuum-assisted ultrasound-guided breast biopsy instruments compared to ultrasound-guided 14-gauge spring-loaded core-needle biopsy. The American Society of Breast Surgeons' Mastery of Breast Surgery Registry was reviewed. Biopsy findings, any rebiopsy, and the instrument used were abstracted for 31,451 ultrasound-guided biopsy procedures performed between 2001 and July 2014. Rates of cancer diagnosis and rebiopsy were calculated for each instrument. A linear mathematical model was developed to calculate total cost per cancer diagnosis, including procedural costs and the costs of any additional surgical rebiopsy procedures. Mean cost per cancer diagnosis with confidence limits was then determined for 14-gauge spring-loaded core-needle biopsy and 14 different vacuum-assisted instruments. For 14-gauge spring-loaded core-needle biopsy, mean cost per cancer diagnosis was $4346 (4327-$4366). For the vacuum-assisted instruments, mean cost per cancer diagnosis ranged from a low of $3742 ($3732-$3752) to a high of $4779 ($4750-$4809). Vacuum-assisted instruments overall were more cost-effective than core with a mean cost per cancer diagnosis of $4052 ($4038-$4067) (p < 0.05). Tethered vacuum-assisted instruments performed best with a mean cost per cancer diagnosis of $3978 ($3964-$3991) (p < 0.05). Nontethered devices had a mean cost per cancer diagnosis of $4369 ($4350-$4388), a result no better than core (p < 0.05). Ultrasound-guided vacuum-assisted breast biopsy had a lower mean cost per cancer diagnosis than 14-gauge spring-loaded core-needle biopsy. This advantage was only seen in tethered vacuum-assisted instruments. Within device families, larger instruments tended to outperform smaller instruments.
Development of a Hybrid Optical Biopsy Probe to Improve Prostate Cancer Diagnosis
2011-06-01
integrated needle probe can be developed for guiding needle biopsy for prostate cancer diagnosis. Multi-modal optical measurements to be utilized for... needle probe can be developed for guiding needle biopsy for prostate cancer diagnosis. Multi-modal optical measurements to be utilized for the study...tissue, into a transrectal- ultrasound , needle - biopsy probe. In the development phase, documentation to obtain IRB approval for ex vivo human prostate
Turan, Alparslan; Babazade, Rovnat; Elsharkawy, Hesham; Esa, Wael Ali Sakr; Maheshwari, Kamal; Farag, Ehab; Zimmerman, Nicole M; Soliman, Loran Mounir; Sessler, Daniel I
2017-03-01
Ultrasound-guided nerve blocks have become the standard when performing regional nerve blocks in anaesthesia. Infiniti Plus (CIVCO Medical Solutions, Kalona, Iowa, USA) is a needle guide that has been recently developed to help clinicians in performing ultrasound-guided nerve blocks. We tested the hypothesis that femoral nerve catheter placement carried out with the Infiniti Plus needle guide will be quicker to perform than without the Infiniti Plus. Secondary aims were to assess whether the Infiniti Plus needle guide decreased the number of block attempts and also whether it improved needle visibility. A randomised, controlled trial. Cleveland Clinic, Cleveland, Ohio, USA. We enrolled adult patients having elective total knee arthroplasty with a femoral nerve block and femoral nerve catheter. Patients, who were pregnant or those who had preexisting neuropathy involving the surgical limb, coagulopathy, infection at the block site or allergy to local anaesthetics were excluded. Patients were randomised into two groups to receive the ultrasound-guided femoral nerve catheter placement with or without the Infiniti Plus needle guide. The time taken to place the femoral nerve catheter, the number of attempts, the success rate and needle visibility were recorded. We used an overall α of 0.05 for both the primary and secondary analyses; the secondary analyses were Bonferroni corrected to control for multiple comparisons. The median (interquartile range Q1 to Q3) time to perform the femoral nerve catheter placement was 118 (100 to 150) s with Infiniti Plus and 177 (130 to 236) s without Infiniti Plus. Infiniti Plus significantly reduced the time spent performing femoral nerve catheterisation, with estimated ratio of means [(95% confidence interval), P value] of 0.67 [(0.60 to 0.75), P < 0.001] with Infiniti Plus compared with no Infiniti Plus. However, Infiniti Plus had no effect on the odds of a successful femoral nerve catheter placement, number of attempts or percentage of perfect needle visibility. We found that the use of Infiniti Plus decreased the median time to successfully place a femoral nerve catheter by 33% compared with not using Infiniti Plus. This difference may be more apparent to clinicians undertaking this procedure less often or by those in training as our team was very experienced, had been trained in the technique and was working in a hospital with a large caseload. Clinicaltrials.gov identifier: NCT02080481.
Guiding intramuscular diaphragm injections using real-time ultrasound and electromyography.
Sarwal, Aarti; Cartwright, Michael S; Mitchell, Erin; Williams, Koudy; Walker, Francis O; Childers, Martin K
2015-02-01
We describe a unique method that combines ultrasound and electromyography to guide intramuscular diaphragm injections in anesthetized large animals. Ultrasound was used to visualize the diaphragm on each side of spontaneously breathing, anesthetized beagle dogs and cynomolgus macaques. An electromyography (EMG) needle was introduced and directed by ultrasound to confirm that the needle entered the muscular portion of the diaphragm, and methylene blue was injected. Injection accuracy was confirmed upon necropsy by tracking the spread of methylene blue. All methylene blue injections were confirmed to have been placed appropriately into the diaphragm. This study demonstrates the feasibility and accuracy of using ultrasound and EMG to guide injections and to reduce complications associated with conventional blind techniques. Ultrasound guidance can be used for clinical EMG of the diaphragm. Future applications may include targeted diaphragm injections with gene replacement therapy in neuromuscular diseases. © 2014 Wiley Periodicals, Inc.
Guiding Intramuscular Diaphragm Injections Using Real-time Ultrasound & Electromyography
Sarwal, Aarti; Cartwright, Michael S.; Mitchell, Erin; Williams, Koudy; Walker, Francis O.; Childers, Martin K.
2014-01-01
Introduction We describe a unique method that combines ultrasound and electromyography to guide intramuscular diaphragm injections in anesthetized large animals. Methods Ultrasound was used to visualize the diaphragm on each side of spontaneously breathing, anesthetized beagle dogs and cynomolgus macaques. An electromyography needle was introduced and directed by ultrasound to confirm that the needle entered the muscular portion of the diaphragm, and methylene blue was injected. Injection accuracy was confirmed upon necropsy by tracking the spread of methylene blue. Results All methylene blue injections were confirmed to have been placed appropriately into the diaphragm. Conclusions This study demonstrates the feasibility and accuracy of using ultrasound and EMG to guide injections and to reduce complications associated with conventional blind techniques. Ultrasound guidance can be used for clinical electromyography of the diaphragm. Future applications may include targeted diaphragm injections with gene replacement therapy in neuromuscular diseases. PMID:25354257
A serious game for learning ultrasound-guided needle placement skills.
Chan, Wing-Yin; Qin, Jing; Chui, Yim-Pan; Heng, Pheng-Ann
2012-11-01
Ultrasound-guided needle placement is a key step in a lot of radiological intervention procedures such as biopsy, local anesthesia and fluid drainage. To help training future intervention radiologists, we develop a serious game to teach the skills involved. We introduce novel techniques for realistic simulation and integrate game elements for active and effective learning. This game is designed in the context of needle placement training based on the some essential characteristics of serious games. Training scenarios are interactively generated via a block-based construction scheme. A novel example-based texture synthesis technique is proposed to simulate corresponding ultrasound images. Game levels are defined based on the difficulties of the generated scenarios. Interactive recommendation of desirable insertion paths is provided during the training as an adaptation mechanism. We also develop a fast physics-based approach to reproduce the shadowing effect of needles in ultrasound images. Game elements such as time-attack tasks, hints and performance evaluation tools are also integrated in our system. Extensive experiments are performed to validate its feasibility for training.
Real-Time Ultrasound-Guided Spinal Anaesthesia: A Prospective Observational Study of a New Approach
Conroy, P. H.; Luyet, C.; McCartney, C. J.; McHardy, P. G.
2013-01-01
Identification of the subarachnoid space has traditionally been achieved by either a blind landmark-guided approach or using prepuncture ultrasound assistance. To assess the feasibility of performing spinal anaesthesia under real-time ultrasound guidance in routine clinical practice we conducted a single center prospective observational study among patients undergoing lower limb orthopaedic surgery. A spinal needle was inserted unassisted within the ultrasound transducer imaging plane using a paramedian approach (i.e., the operator held the transducer in one hand and the spinal needle in the other). The primary outcome measure was the success rate of CSF acquisition under real-time ultrasound guidance with CSF being located in 97 out of 100 consecutive patients within median three needle passes (IQR 1–6). CSF was not acquired in three patients. Subsequent attempts combining landmark palpation and pre-puncture ultrasound scanning resulted in successful spinal anaesthesia in two of these patients with the third patient requiring general anaesthesia. Median time from spinal needle insertion until intrathecal injection completion was 1.2 minutes (IQR 0.83–4.1) demonstrating the feasibility of this technique in routine clinical practice. PMID:23365568
Simulators for training in ultrasound guided procedures.
Farjad Sultan, Syed; Shorten, George; Iohom, Gabrielle
2013-06-01
The four major categories of skill sets associated with proficiency in ultrasound guided regional anaesthesia are 1) understanding device operations, 2) image optimization, 3) image interpretation and 4) visualization of needle insertion and injection of the local anesthetic solution. Of these, visualization of needle insertion and injection of local anaesthetic solution can be practiced using simulators and phantoms. This survey of existing simulators summarizes advantages and disadvantages of each. Current deficits pertain to the validation process.
Wang, Cai-Xia; Wang, Jian; Chen, Yuan-Yuan; Wang, Jia-Ni; Yu, Xin; Yang, Feng; Sun, Si-Yu
2016-12-14
To evaluate the efficacy and safety of nitrous oxide-sedated endoscopic ultrasound-guided fine needle aspiration. Enrolled patients were divided randomly into an experimental group (inhalation of nitrous oxide) and a control group (inhalation of pure oxygen) and heart rate, blood oxygen saturation, blood pressure, electrocardiogram (ECG) changes, and the occurrence of complications were monitored and recorded. All patients and physicians completed satisfaction questionnaires about the examination and scored the process using a visual analog scale. There was no significant difference in heart rate, blood oxygen saturation, blood pressure, ECG changes, or complication rate between the two groups of patients ( P > 0.05). However, patient and physician satisfaction were both significantly higher in the nitrous oxide compared with the control group ( P < 0.05). Nitrous oxide-sedation is a safe and effective option for patients undergoing endoscopic ultrasound-guided fine needle aspiration.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Drinkovic, Ivan; Brkljacic, Boris
1996-09-15
Two cases with lethal complications are reported among 1750 ultrasound (US)-guided percutaneous fine-needle liver biopsies performed in our department. The first patient had angiosarcoma of the liver which was not suspected after computed tomography (CT) and US studies had been performed. The other patient had hepatocellular carcinoma in advanced hepatic cirrhosis. Death was due to bleeding in both cases. Pre-procedure laboratory tests did not reveal the existence of major bleeding disorders in either case. Normal liver tissue was interposed in the needle track between the liver capsule and the lesions which were targeted.
Ultrasound-guided peripheral nerve blockade.
Chin, Ki Jinn; Chan, Vincent
2008-10-01
The use of ultrasound for peripheral nerve blockade is becoming popular. Although the feasibility of ultrasound-guided nerve blockade is now clear, it is uncertain at this time whether it represents the new standard for regional anesthesia in terms of efficacy and safety. The ability to visualize nerve location, needle advancement, needle-nerve interaction, and local anesthetic spread makes ultrasound-guided nerve block an attractive option. Study results indicate that these advantages can improve the ease of block performance, block success rates, and complications. At the same time there is evidence that ultrasound-guided regional anesthesia is a unique skill in its own right, and that proficiency in it requires training and experience. Ultrasound is a valuable tool that is now available to the regional anesthesiologist, and it is fast becoming a standard part of practice. It promises to be of especial value to the less experienced practitioner. Ultrasound does not in itself, however, guarantee the efficacy and safety of peripheral nerve blockade. Proper training in its use is required and we can expect to see the development of formal standards and guidelines in this regard.
Real-time visualization of ultrasound-guided retrobulbar blockade: an imaging study.
Luyet, C; Eichenberger, U; Moriggl, B; Remonda, L; Greif, R
2008-12-01
Retrobulbar anaesthesia allows eye surgery in awake patients. Severe complications of the blind techniques are reported. Ultrasound-guided needle introduction and direct visualization of the spread of local anaesthetic may improve quality and safety of retrobulbar anaesthesia. Therefore, we developed a new ultrasound-guided technique using human cadavers. In total, 20 blocks on both sides in 10 embalmed human cadavers were performed. Using a small curved array transducer and a long-axis approach, a 22 G short bevel needle was introduced under ultrasound guidance lateral and caudal of the eyeball until the needle tip was seen 2 mm away from the optic nerve. At this point, 2 ml of contrast dye as a substitute for local anaesthetic was injected. Immediately after the injection, the spread of the contrast dye was documented by means of CT scans performed in each cadaver. The CT scans showed the distribution of the contrast dye in the muscle cone and behind the posterior sclera in all but one case. No contrast dye was found inside the optic nerve or inside the eyeball. In one case, there could be an additional trace of contrast dye behind the orbita. Our new ultrasound-guided technique has the potential to improve safety and efficacy of the procedure by direct visualization of the needle placement and the distribution of the injected fluid. Furthermore, the precise injection near the optic nerve could lead to a reduction of the amount of the local anaesthetic needed with fewer related complications.
Izumo, Takehiro; Matsumoto, Yuji; Sasada, Shinji; Chavez, Christine; Nakai, Toshiyuki; Tsuchida, Takaaki
2017-03-01
The utility of rapid on-site evaluation during endobronchial ultrasound with a guide sheath for peripheral pulmonary lesions is unclear. The aim of this study was to evaluate the role of rapid on-site evaluation during endobronchial ultrasound with a guide sheath for peripheral pulmonary lesions. Consecutive patients who underwent endobronchial ultrasound with a guide sheath for the diagnosis of peripheral pulmonary lesions at our hospital between September 2012 and July 2014 were included in this retrospective study. Cytology slides were air-dried, and modified Giemsa (Diff-Quik) staining was used for rapid on-site evaluation. Additional smears were prepared for Papanicolaou staining and tissue samples were placed in formalin for histologic evaluation. The results of rapid on-site evaluation were compared with the final diagnoses of endobronchial ultrasound with a guide sheath. A total of 718 cases were included in the study population. The sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy of rapid on-site evaluation during endobronchial ultrasound with a guide sheath for peripheral pulmonary lesions was 88.6%, 65.9%, 81.2%, 77.7% and 80.1%, respectively. There were no procedure-related deaths. Rapid on-site evaluation during endobronchial ultrasound with a guide sheath had high sensitivity for peripheral pulmonary lesions. When carrying out rapid on-site evaluation of transbronchial biopsy samples from peripheral pulmonary lesions, careful interpretation and clinical correlation are necessary. © The Author 2016. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com
Hodges, P W; Kippers, V; Richardson, C A
1997-01-01
Fine-wire electromyography is primarily utilised for the recording of activity of the deep musculature, however, due to the location of these muscles, accurate electrode placement is difficult. Real-time ultrasound imaging (RTUI) of muscle tissue has been used for the guidance of the needle insertion for the placement of electrodes into the muscles of the abdominal wall. The validity of RTUI guidance of needle insertion into the deep muscles has not been determined. A cadaveric study was conducted to evaluate the accuracy with which RTUI can be used to guide fine-wire electrode placement using the posterior fibres of gluteus medius (PGM) as an example. Pilot studies revealed that the ultrasound resolution of cadaveric tissue is markedly reduced making it impossible to directly evaluate the technique, therefore, three studies were conducted. An initial study involved the demarcation of the anatomical boundaries of PGM using RTUI to define a technique based on an anatomical landmark that was consisent with the in vivo RTUI guided needle placement technique. This anatomical landmark was then used as the guide for the cadaveric needle insertion. Once the needle was positioned 0.05 ml of dye was introduced and the specimen dissected. The dye was accurately placed in PGM in 100% of the specimens. Finally, fine-wire electrodes were inserted into the PGM of five volunteers and manoeuvres performed indicating the accuracy of placement. This study supports the use of ultrasound imaging for the accurate guidance of needle insertion for fine-wire and needle EMG electrodes.
Kuang, Y; Hilgers, A; Sadiq, M; Cochran, S; Corner, G; Huang, Z
2016-07-01
Clear needle visualisation is recognised as an unmet need for ultrasound guided percutaneous needle procedures including regional anaesthesia and tissue biopsy. With inadequate needle visibility, these procedures may result in serious complications or a failed operation. This paper reports analysis of the modal behaviour of a previously proposed ultrasound-actuated needle configuration, which may overcome this problem by improving needle visibility in colour Doppler imaging. It uses a piezoelectric transducer to actuate longitudinal resonant modes in needles (outer diameter 0.8-1.2mm, length>65mm). The factors that affect the needle's vibration mode are identified, including the needle length, the transducer's resonance frequency and the gripping position. Their effects are investigated using finite element modelling, with the conclusions validated experimentally. The actuated needle was inserted into porcine tissue up to 30mm depth and its visibility was observed under colour Doppler imaging. The piezoelectric transducer is able to generate longitudinal vibration with peak-to-peak amplitude up to 4μm at the needle tip with an actuating voltage of 20Vpp. Actuated in longitudinal vibration modes (distal mode at 27.6kHz and transducer mode at 42.2kHz) with a drive amplitude of 12-14Vpp, a 120mm needle is delineated as a coloured line in colour Doppler images, with both needle tip and shaft visualised. The improved needle visibility is maintained while the needle is advanced into the tissue, thus allowing tracking of the needle position in real time. Moreover, the needle tip is highlighted by strong coloured artefacts around the actuated needle generated by its flexural vibration. A limitation of the technique is that the transducer mode requires needles of specific lengths so that the needle's resonance frequency matches the transducer. This may restrict the choice of needle lengths in clinical applications. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.
Ultrasound-guided injection of botulinum toxin A in the treatment of iliopsoas spasticity
Sconfienza, L.M.; Perrone, N.; Lacelli, F.; Lentino, C.; Serafini, G.
2008-01-01
Purpose Intramuscular injection of botulinum toxin A (BTX-A) is a common treatment for iliopsoas muscle spasticity, but it is not easy to position the needle in this muscle without guidance. In this paper we describe an ultrasound-guided technique for the intramuscular injection of BTX-A to treat spasticity of the iliopsoas muscle. Its effectiveness was assessed in 10 patients. Method and materials The ultrasound-guided technique for BTX-A injection was used on 10 patients. The needle was inserted into the muscle belly at an angle of 45° along the longitudinal axis of the muscle when allowed by patient's condition. Results In all cases, the iliopsoas muscle was easily identified and both the iliac and psoas components were assessed. Introduction of the needle and drug injection were entirely carried out under ultrasonographic guidance. The procedure was successful in all patients, even in those with a high-grade spasticity, and general anesthesia was not required. Conclusions This ultrasound-guided technique allows accurate guidance for the injection of BTX-A, and it can be considered as an alternate supportive therapy in patients with spasticity and dystonia. PMID:23396653
Lee, Kenneth S; Rosas, Humberto G
2010-09-01
The purpose of this video article is to illustrate the ultrasound appearance of calcium deposition in the rotator cuff and provide a detailed step-by-step protocol for performing the ultrasound-guided single-needle lavage technique for the treatment of calcific tendinitis with emphasis on patient positioning, necessary supplies, real-time lavage technique, and steroid injection into the subacromial subdeltoid bursa. Musculoskeletal ultrasound is well established as a safe, cost-effective imaging tool in diagnosing and treating common musculoskeletal disorders. Calcific tendinitis of the rotator cuff is a common disabling cause of shoulder pain. Although most cases are self-limiting, a subset of patients is refractory to conservative therapy and requires treatment intervention. Ultrasound-guided lavage is an effective and safe minimally-invasive treatment not readily offered in the United States as an alternative to surgery, perhaps because of the limited prevalence of musculoskeletal ultrasound programs and limited training. On completion of this video article, the participant should be able to develop an appropriate diagnostic and therapeutic algorithm for the treatment of calcific tendinitis of the rotator cuff using ultrasound.
Lai, Hung-Wen; Wu, Hwa-Koon; Kuo, Shou-Jen; Chen, Shou-Tung; Tseng, Hsin-Shun; Tseng, Ling-Ming; Chen, Dar-Ren
2013-04-01
Core needle biopsy (CNB) was widely used in the diagnosis of ultrasound-detectable breast lesions. We aimed at assessing the diagnostic performance differences between 14- and 16-gauge ultrasound-guided core biopsies. This retrospective study enrolled patients receiving CNB from January 2001 to December 2007. The results of 14- and 16-gauge breast CNBs were compared with pathology reports of open surgical biopsy (OSB). A total of 1024 paired CNB and OSB results were obtained from 1732 CNB procedures in 1630 patients.Those CNB results reached 92.9% sensitivity, 99.7% specificity, 5.96% underestimation, and 94.8% accuracy rates. There was no difference in sensitivity (p=0.17) or specificity (p=0.38) between 14- and 16-gauge needles. However, better overall accuracy (p=0.02), less underestimation (p<0.001), and lower false-negative (p=0.02) rates were found for the 14-gauge CNB. Regarding accuracy and underestimation rates, a 14-gauge needle is preferred to a 16-gauge one in ultrasound-guided biopsies. Copyright © 2012. Published by Elsevier B.V.
Accuracy of electromyography needle placement in cadavers: non-guided vs. ultrasound guided.
Boon, Andrea J; Oney-Marlow, Theresa M; Murthy, Naveen S; Harper, Charles M; McNamara, Terrence R; Smith, Jay
2011-07-01
Accuracy of needle electromyography is typically ensured by use of anatomical landmarks and auditory feedback related to voluntary activation of the targeted muscle; however, in certain clinical situations, landmarks may not be palpable, auditory feedback may be limited or not present, and targeting a specific muscle may be more critical. In such settings, image guidance might significantly enhance accuracy. Two electromyographers with different levels of experience examined 14 muscles in each of 4 fresh-frozen cadaver lower limbs. Each muscle was tested a total of eight times; four fine wires were inserted without ultrasound (US) guidance and four were inserted under US guidance. Overall accuracy as well as accuracy rates for the individual electromyographers were calculated. Non-guided needle placement was significantly less accurate than US-guided needle placement, particularly in the hands of less experienced electromyographers, supporting the use of real-time US guidance in certain challenging situations in the electromyography laboratory. Copyright © 2011 Wiley Periodicals, Inc.
Wang, Hailing; Li, Fangxuan; Liu, Juntian; Zhang, Sheng
2014-01-01
Ultrasound-guided core needle biopsy of abdominal and pelvic masses in adults has gained tremendous popularity. However, the application of the same treatment in children is not as popular because of apprehensions regarding inadequate tissues for the biopsy and accidental puncture of vital organs. Data of the application of ultrasound-guided core needle biopsy in 105 pediatric patients with clinically or ultrasound-diagnosed abdominopelvic masses were reviewed. Diagnostic procedures were conducted in our institution from May 2011 to May 2013. The biopsies were conducted on 86 malignant lesions and 19 benign lesions. 86 malignant tumors comprised neuroblastomas (30 cases), hepatoblastomas (15 cases), nephroblastomas (11 cases), and primitive neuroectodermal tumors/malignant small round cells (6 cases). Among malignant tumor cases, only a pelvic primitive neuroectodermal tumor did not receive a pathological diagnosis. Therefore, the biopsy accuracy was 98.8 % in malignant tumor. However, the biopsies for one neuroblastomas and one malignant small round cell tumor were inadequate for cytogenetic analysis. Therefore, 96.5 % of the malignant tumor patients received complete diagnosis via biopsy. 19 benign tumors comprised mature teratoma (10 cases), hemangioendothelioma (3 cases), paraganglioma (2 cases), and infection (2 cases). The diagnostic accuracy for benign neoplasm was 100 %. Five patients experienced postoperative complications, including pain (2 patients), bleeding from the biopsy site (2 patients), and wound infection (1 patient). Ultrasound-guided core needle biopsy is an efficient, minimally invasive, accurate, and safe diagnostic method that can be applied in the management of abdominal or pelvic mass of pediatric patients.
Verma, Akash; Goh, Kee San; Phua, Chee Kiang; Sim, Wen Yuan; Tee, Kuan Sen; Lim, Albert Y.H.; Tai, Dessmon Y.H.; Goh, Soon Keng; Kor, Ai Ching; Ho, Benjamin; Lew, Sennen J.W.; Abisheganaden, John
2016-01-01
Abstract To compare the performance of convex probe endobronchial ultrasound guided transbronchial needle aspiration (EBUS-TBNA) with conventional endobronchial biopsy (EBB) or transbronchial lung biopsy (TBLB) in patients with mediastinal, and coexisting endobronchial or peripheral lesions. Retrospective review of records of patients undergoing diagnostic EBUS-TBNA and conventional bronchoscopy in 2014. A total of 74 patients had mediastinal, and coexisting endobronchial or peripheral lesions. The detection rate of EBUS-TBNA for mediastinal lesion >1 cm in short axis, EBB for visible exophytic type of endobronchial lesion, and TBLB for peripheral lesion with bronchus sign were 71%, 75%, and 86%, respectively. In contrast, the detection rate of EBUS-TBNA for mediastinal lesion ≤1 cm in short axis, EBB for mucosal hyperemia type of endobronchial lesion, and TBLB for peripheral lesion without bronchus sign were 25%, 63%, and 38%, and improved to 63%, 88%, and 62% respectively by adding EBB or TBLB to EBUS-TBNA, and EBUS-TBNA to EBB or TBLB. Postprocedure bleeding was significantly more common in patients undergoing EBB and TBLB 8 (40%) versus convex probe EBUS-TBNA 2 patients (2.7%, P = 0.0004). EBUS-TBNA is a safer single diagnostic technique compared with EBB or TBLB in patients with mediastinal lesion of >1 cm in size, and coexisting exophytic type of endobronchial lesion, or peripheral lesion with bronchus sign. However, it requires combining with EBB or TBLB and vice versa to optimize yield when mediastinal lesion is ≤1 cm in size, and coexisting endobronchial and peripheral lesions lack exophytic nature, and bronchus sign, respectively. PMID:27977603
Radial-probe EBUS for the diagnosis of peripheral pulmonary lesions
Jacomelli, Marcia; Demarzo, Sergio Eduardo; Cardoso, Paulo Francisco Guerreiro; Palomino, Addy Lidvina Mejia; Figueiredo, Viviane Rossi
2016-01-01
ABSTRACT Objective: Conventional bronchoscopy has a low diagnostic yield for peripheral pulmonary lesions. Radial-probe EBUS employs a rotating ultrasound transducer at the end of a probe that is passed through the working channel of the bronchoscope. Radial-probe EBUS facilitates the localization of peripheral pulmonary nodules, thus increasing the diagnostic yield. The objective of this study was to present our initial experience using radial-probe EBUS in the diagnosis of peripheral pulmonary lesions at a tertiary hospital. Methods: We conducted a retrospective analysis of 54 patients who underwent radial-probe EBUS-guided bronchoscopy for the investigation of pulmonary nodules or masses between February of 2012 and September of 2013. Radial-probe EBUS was performed with a flexible 20-MHz probe, which was passed through the working channel of the bronchoscope and advanced through the bronchus to the target lesion. For localization of the lesion and for collection procedures (bronchial brushing, transbronchial needle aspiration, and transbronchial biopsy), we used fluoroscopy. Results: Radial-probe EBUS identified 39 nodules (mean diameter, 1.9 ∓ 0.7 cm) and 19 masses (mean diameter, 4.1 ∓ 0.9 cm). The overall sensitivity of the method was 66.7% (79.5% and 25.0%, respectively, for lesions that were visible and not visible by radial-probe EBUS). Among the lesions that were visible by radial-probe EBUS, the sensitivity was 91.7% for masses and 74.1% for nodules. The complications were pneumothorax (in 3.7%) and bronchial bleeding, which was controlled bronchoscopically (in 9.3%). Conclusions: Radial-probe EBUS shows a good safety profile, a low complication rate, and high sensitivity for the diagnosis of peripheral pulmonary lesions. PMID:27832231
Real-time three-dimensional optical coherence tomography image-guided core-needle biopsy system.
Kuo, Wei-Cheng; Kim, Jongsik; Shemonski, Nathan D; Chaney, Eric J; Spillman, Darold R; Boppart, Stephen A
2012-06-01
Advances in optical imaging modalities, such as optical coherence tomography (OCT), enable us to observe tissue microstructure at high resolution and in real time. Currently, core-needle biopsies are guided by external imaging modalities such as ultrasound imaging and x-ray computed tomography (CT) for breast and lung masses, respectively. These image-guided procedures are frequently limited by spatial resolution when using ultrasound imaging, or by temporal resolution (rapid real-time feedback capabilities) when using x-ray CT. One feasible approach is to perform OCT within small gauge needles to optically image tissue microstructure. However, to date, no system or core-needle device has been developed that incorporates both three-dimensional OCT imaging and tissue biopsy within the same needle for true OCT-guided core-needle biopsy. We have developed and demonstrate an integrated core-needle biopsy system that utilizes catheter-based 3-D OCT for real-time image-guidance for target tissue localization, imaging of tissue immediately prior to physical biopsy, and subsequent OCT imaging of the biopsied specimen for immediate assessment at the point-of-care. OCT images of biopsied ex vivo tumor specimens acquired during core-needle placement are correlated with corresponding histology, and computational visualization of arbitrary planes within the 3-D OCT volumes enables feedback on specimen tissue type and biopsy quality. These results demonstrate the potential for using real-time 3-D OCT for needle biopsy guidance by imaging within the needle and tissue during biopsy procedures.
Wang, Cai-Xia; Wang, Jian; Chen, Yuan-Yuan; Wang, Jia-Ni; Yu, Xin; Yang, Feng; Sun, Si-Yu
2016-01-01
AIM To evaluate the efficacy and safety of nitrous oxide-sedated endoscopic ultrasound-guided fine needle aspiration. METHODS Enrolled patients were divided randomly into an experimental group (inhalation of nitrous oxide) and a control group (inhalation of pure oxygen) and heart rate, blood oxygen saturation, blood pressure, electrocardiogram (ECG) changes, and the occurrence of complications were monitored and recorded. All patients and physicians completed satisfaction questionnaires about the examination and scored the process using a visual analog scale. RESULTS There was no significant difference in heart rate, blood oxygen saturation, blood pressure, ECG changes, or complication rate between the two groups of patients (P > 0.05). However, patient and physician satisfaction were both significantly higher in the nitrous oxide compared with the control group (P < 0.05). CONCLUSION Nitrous oxide-sedation is a safe and effective option for patients undergoing endoscopic ultrasound-guided fine needle aspiration. PMID:28028373
Electrolytic echo enhancement: a novel method to make needles more reflective to ultrasound.
Cockburn, John F; Khosh, Stefan K
2014-04-01
This study examines the effect of augmenting the ultrasound reflectivity of needles using a novel electrolytic echo enhancement method. Needles were connected by a lead to the negative terminal of a 4.5 V direct current source. A grounding pad, connected to the positive terminal, was positioned on the undersurface of an ex vivo ox liver phantom. During needle insertion into the liver, electrolysis was induced creating a layer of gas on the needle electrode. Analysis of images showed a significant increase in needle brightness using electrolytic echo enhancement. Brightness was found to increase by a factor of ×3.6 compared with controls (P < 0.001). Electrolytic echo enhancement has the potential to make ultrasound-guided procedures safer and quicker for patients and increase the confidence of operators in their ability to see the whole needle including its tip. © 2014 The Royal Australian and New Zealand College of Radiologists.
Okasha, Hussein Hassan; Naga, Mazen Ibrahim; Esmat, Serag; Naguib, Mohamed; Hassanein, Mohamed; Hassani, Mohamed; El-Kassas, Mohamed; Mahdy, Reem Ezzat; El-Gemeie, Emad; Farag, Ali Hassan; Foda, Ayman Mohamed
2013-01-01
Objective: Pancreatic carcinoma is one of the leading cancer morbidity and mortality world-wide. Controversy has arisen about whether the percutaneous approach with computed tomography/ultrasonography-guidance fine needle aspiration (US-FNA) or endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) is the preferred method to obtain diagnostic tissue. Our purpose of this study is to compare between the diagnostic accuracy of EUS-FNA and percutaneous US-FNA in diagnosis of pancreatic cancer. Patients and Methods: A total of 197 patients with pancreatic masses were included in the study, 125 patients underwent US-FNA (Group 1) and 72 patients underwent EUS-FNA (Group 2). Results: EUS-FNA has nearly the same accuracy (88.9%) as US-FNA (87.2%) in diagnosis of pancreatic cancer. The sensitivity, specificity, positive predictive value and negative predictive value for EUS-FNA was 84%, 100%, 100%, 73.3% respectively. It was 85.5%, 90.4%, 94.7%, 76% respectively for US-FNA. EUS-FNA had a lower complication rate (1.38%) than US-FNA (5.6%). Conclusion: EUS-FNA has nearly the same accuracy as US-FNA of pancreatic masses with a lower complication rate. PMID:24949394
Ma, Kai; Huang, Xiao-bo; Xiong, Liu-lin; Xu, Qing-quan; Xu, Tao; Ye, Hai-yun; Yu, Lu-ping; Wang, Xiao-feng
2014-08-18
To evaluate the feasibility and efficacy of percutaneous renal puncture in percutaneous nephrolithotomy guided by novel needle-tracking ultrasound system. From may to october 2013, 16 cases of percutaneous nephrolithotomy were performed under the guidance of ultrasound system. The clinical data including the time of completing percutaneous renal puncture, the color of urine sucked out from the kidney calices, and the complications were analyzed retrospectively. Of the 16 patients, 18 percutaneous renal access were established guided by ultrasound system. All of them were successtul for the first time, and the average time of completing percutaneous renal punctures was (26.90 ± 11.37) s (15 to 54 s). After the operation, the hemoglobin decreased by (9.56 ± 5.27)%(1.41% to 24.06%), and no complications occurred except for postoperative fever in 2 case. The novel ultrasound system is a safe and effective technique that can reduce the technical difficulty of percutaneous renal puncture in percutaneous nephrolithotomy.
Objective assessment of operator performance during ultrasound-guided procedures.
Tabriz, David M; Street, Mandie; Pilgram, Thomas K; Duncan, James R
2011-09-01
Simulation permits objective assessment of operator performance in a controlled and safe environment. Image-guided procedures often require accurate needle placement, and we designed a system to monitor how ultrasound guidance is used to monitor needle advancement toward a target. The results were correlated with other estimates of operator skill. The simulator consisted of a tissue phantom, ultrasound unit, and electromagnetic tracking system. Operators were asked to guide a needle toward a visible point target. Performance was video-recorded and synchronized with the electromagnetic tracking data. A series of algorithms based on motor control theory and human information processing were used to convert raw tracking data into different performance indices. Scoring algorithms converted the tracking data into efficiency, quality, task difficulty, and targeting scores that were aggregated to create performance indices. After initial feasibility testing, a standardized assessment was developed. Operators (N = 12) with a broad spectrum of skill and experience were enrolled and tested. Overall scores were based on performance during ten simulated procedures. Prior clinical experience was used to independently estimate operator skill. When summed, the performance indices correlated well with estimated skill. Operators with minimal or no prior experience scored markedly lower than experienced operators. The overall score tended to increase according to operator's clinical experience. Operator experience was linked to decreased variation in multiple aspects of performance. The aggregated results of multiple trials provided the best correlation between estimated skill and performance. A metric for the operator's ability to maintain the needle aimed at the target discriminated between operators with different levels of experience. This study used a highly focused task model, standardized assessment, and objective data analysis to assess performance during simulated ultrasound-guided needle placement. The performance indices were closely related to operator experience.
Hao, Shuang; Liu, Zhe-Bin; Ling, Hong; Chen, Jia-Jian; Shen, Ju-Ping; Yang, Wen-Tao; Shao, Zhi-Min
2015-01-01
Diagnostic patterns in breast cancer have greatly changed over the past few decades, and core needle biopsy (CNB) has become a reliable procedure for detecting breast cancer without invasive surgery. To estimate the changing diagnostic patterns of breast cancer in urban Shanghai, 11,947 women with breast lesions detected by preoperative needle biopsy between January 1995 and December 2012 were selected from the Shanghai Cancer Data base, which integrates information from approximately 50% of breast cancer patients in Shanghai. The CNB procedure uses an automated prone unit, biopsy gun, and 14-gauge needles under freehand or ultrasound guidance and was performed by experienced radiologists and surgeons specializing in needle biopsies. Diagnosis and classification for each patient were independently evaluated by pathologists. Over the indicated 8-year period, biopsy type consisted of 11,947 ultrasound-guided core needle biopsies (UCNBs), 2,015 ultrasound-guided vacuum-assisted biopsies (UVABs), and 654 stereotactic X-ray-guided vacuum-assisted biopsies (XVABs). For all the 11,947 women included in this study, image-guided needle biopsy was the initial diagnostic procedure. Approximately 81.0% of biopsied samples were histopathologically determined to be malignant lesions, 5.5% were determined to be high-risk lesions, and 13.5% were determined to be benign lesions. The number of patients choosing UCNB increased at the greatest rate, and UCNB has become a standard procedure for histodiagnosis because it is inexpensive, convenient, and accurate. The overall false-negative rate of CNB was 1.7%, and the specific false-negative rates for UCNB, UVAB, and XVAB, were 1.7%, 0%, and 0%, respectively. This study suggests that the use of preoperative needle biopsy as the initial breast cancer diagnostic procedure is acceptable in urban Shanghai. Preoperative needle biopsy is now a standard procedure in the Shanghai Cancer Center because it may reduce the number of surgeries needed to treat breast cancer. PMID:26491359
Development of a Hybrid Optical Biopsy Probe to Improve Prostate Cancer Diagnosis
2012-06-01
can be developed for guiding needle biopsy for prostate cancer diagnosis. Multi-modal optical measurements to be utilized for the study are (1) light...which collect light scattering and auto-fluorescence from the prostate tissue, into a transrectal- ultrasound , needle - biopsy probe. In the...probe can be developed for guiding needle biopsy for prostate cancer diagnosis. Multi-modal optical measurements to be utilized for the study were
Examples of Radiation-Emitting Products
... Ultrasonography • Doppler ultrasound • Color doppler ultrasound • Hyperthermia • Diathermy/physical therapy • Bone healing • Lithotripsy • Phacoemulsifier • Needle guide • Bone density measuring • Geriatric bath (ultrasound) • Hearing aid • Many scientific uses • Nondestructive ...
[Lactational breast abscesses: Do we still need surgery?].
Debord, M-P; Poirier, E; Delgado, H; Charlot, M; Colin, C; Raudrant, D; Golfier, F; Dupuis, O
2016-03-01
To show the effectiveness of ultrasound-guided puncture in the treatment of lactational breast abscess and identify its risk factors. Retrospective descriptive study at the CHU of Lyon-Sud from December 2007 to December 2013, including patients with lactational breast abscess confirmed on ultrasound and treated with antibiotics and analgesics. Realisation of ultrasound-guided needle under local anesthesia by the radiologist and washing the cavity with physiological serum. Forty patients had lactational abscesses at an average of 10 weeks post-partum. Thirty-four patients were treated by needle aspiration, of which 2 had first surgical drainage. The average size of the abscess was 41.2mm. The success rate of needle aspiration was 91.2%. No cases of recurrence were observed, however, there were 5 fistulisations. In all, 91.2% were treated on an outpatient basis. In 87.8% of cases, breastfeeding was continued on the healthy side and in 48.5% of cases on the affected side. The major risk factor for abscess was mastitis in 91.1% of cases. Ultrasound guidance of needle aspiration should be gold standard for the treatment of lactational breast abscesses to continue breastfeeding including the affected side. Copyright © 2015. Published by Elsevier Masson SAS.
Feasibility of ultrasound-guided epidural access at the lumbo-sacral space in dogs.
Liotta, Annalisa; Busoni, Valeria; Carrozzo, Maria Valentina; Sandersen, Charlotte; Gabriel, Annick; Bolen, Géraldine
2015-01-01
Epidural injections are commonly performed blindly in veterinary medicine. The aims of this study were to describe the lumbosacral ultrasonographic anatomy and to assess the feasibility of an ultrasound-guided epidural injection technique in dogs. A cross sectional anatomic atlas of the lumbosacral region and ex vivo ultrasound images were obtained in two cadavers to describe the ultrasound anatomy and to identify the landmarks. Sixteen normal weight canine cadavers were used to establish two variations of the technique for direct ultrasound-guided injection, using spinal needles or epidural catheters. The technique was finally performed in two normal weight cadavers, in two overweight cadavers and in five live dogs with radiographic abnormalities resulting of the lumbosacral spine. Contrast medium was injected and CT was used to assess the success of the injection. The anatomic landmarks to carry out the procedure were the seventh lumbar vertebra, the iliac wings, and the first sacral vertebra. The target for directing the needle was the trapezoid-shaped echogenic zone between the contiguous articular facets of the lumbosacral vertebral canal visualized in a parasagittal plane. The spinal needle or epidural catheter was inserted in a 45° craniodorsal-caudoventral direction through the subcutaneous tissue and the interarcuate ligament until reaching the epidural space. CT examination confirmed the presence of contrast medium in the epidural space in 25/25 dogs, although a variable contamination of the subarachnoid space was also noted. Findings indicated that this ultrasound-guided epidural injection technique is feasible for normal weight and overweight dogs, with and without radiographic abnormalities of the spine. © 2014 American College of Veterinary Radiology.
Ultrasound physics and instrumentation for pathologists.
Lieu, David
2010-10-01
Interest in pathologist-performed ultrasound-guided fine-needle aspiration is increasing. Educational courses discuss clinical ultrasound and biopsy techniques but not ultrasound physics and instrumentation. To review modern ultrasound physics and instrumentation to help pathologists understand the basis of modern ultrasound. A review of recent literature and textbooks was performed. Ultrasound physics and instrumentation are the foundations of clinical ultrasound. The key physical principle is the piezoelectric effect. When stimulated by an electric current, certain crystals vibrate and produce ultrasound. A hand-held transducer converts electricity into ultrasound, transmits it into tissue, and listens for reflected ultrasound to return. The returning echoes are converted into electrical signals and used to create a 2-dimensional gray-scale image. Scanning at a high frequency improves axial resolution but has low tissue penetration. Electronic focusing moves the long-axis focus to depth of the object of interest and improves lateral resolution. The short-axis focus in 1-dimensional transducers is fixed, which results in poor elevational resolution away from the focal zone. Using multiple foci improves lateral resolution but degrades temporal resolution. The sonographer can adjust the dynamic range to change contrast and bring out subtle masses. Contrast resolution is limited by processing speed, monitor resolution, and gray-scale perception of the human eye. Ultrasound is an evolving field. New technologies include miniaturization, spatial compound imaging, tissue harmonics, and multidimensional transducers. Clinical cytopathologists who understand ultrasound physics, instrumentation, and clinical ultrasound are ready for the challenges of cytopathologist-performed ultrasound-guided fine-needle aspiration and core-needle biopsy in the 21st century.
Hızlı, Fatih; Özcan, Osman; Selvi, İsmail; Eraslan, Pınar; Köşüş, Aydın; Baş, Okan; Yıkılmaz, Taha Numan; Güven, Oğuz; Başar, Halil
2015-11-01
Several studies evaluating the tolerance of transrectal ultrasound (TRUS)-guided needle biopsies showed that moderate-to-severe pain was associated with the procedure. Additionally, prebiopsy anxiety or rebiopsy as a result of a prior biopsy procedure is mentioned as factors predisposing to higher pain intensity. Thus, in this study, we investigated the effects of hypnotherapy during transrectal ultrasound-guided prostate needle biopsy for pain and anxiety. Sixty-four patients presenting for TRUS-guided prostate needle biopsy were randomly assigned to receive either 10-min presurgery hypnosis session (n = 32, mean age 63.5 ± 6.1, p = 0.289) or a presurgery control session (n = 32, mean age 61.8 ± 6.8, p = 0.289). The hypnosis session involved suggestions for increased relaxation and decreased anxiety. Presurgery pain and anxiety were measured using visual analog scales (VAS), Beck Anxiety Inventory (BAI), and Hamilton Anxiety Scale (HAS), respectively. In our statistics, p < 0.05 was considered statistically significant. Postintervention, and before surgery, patients in the hypnosis group had significantly lower mean values for presurgery VAS [mean 1 (0-8); p = 0.011], BAI (6.0 vs 2.0; p < 0.001), and HAS (11.0 vs 6.0; p < 0.001). The study results indicate that a brief presurgery hypnosis intervention can be an effective means of controlling presurgical anxiety, and therefore pain, in patients awaiting diagnostic prostate cancer surgery.
Characteristic endobronchial ultrasound image of hemangiopericytoma/solitary fibrous tumor.
Chen, Fengshi; Yoshizawa, Akihiko; Okubo, Kenichi; Date, Hiroshi
2010-09-01
Hemangiopericytomatous pattern is characteristic of hemangiopericytoma/solitary fibrous tumor (HPC/SFT) and certain histological features might indicate a malignant potential, but the behavior of HPC/SFT is unpredictable. Endobronchial ultrasound (EBUS) is a useful diagnostic device in that the ultrasonographic image can be viewed and the EBUS-transbronchial needle aspiration can obtain a biopsied sample. We herein report a patient undergoing multiple surgical resections of recurrent HPC/SFT. A 74-year-old man had undergone right upper lobectomy for HPC/SFT 15 years ago. He received a partial resection of the left lung and a resection of the anterior mediastinal mass for its recurrences 13 years and six years ago, respectively. He had also undergone surgery for gastric carcinoma two years ago. He then presented with a tumor measuring 3 x 4 cm in the subcarinal area. Preoperative EBUS revealed a tumor with abundant thin-walled vessel-like structures, which was consistent with HPC/SFT. The tumor was completely resected and was finally diagnosed as low-grade malignant HPC/SFT.
Beigi, Parmida; Malenfant, Paul; Rasoulian, Abtin; Rohling, Robert; Dube, Alison; Gunka, Vit
2017-01-01
Current 2-D ultrasound technology is unable to perform a midline neuraxial needle insertion under real-time ultrasound guidance using a standard needle and without an assistant. The aim of the work described here was to determine the feasibility of a new technology providing such capability, starting with a study evaluating the selected puncture site. A novel 3-D ultrasound imaging technique was designed using thick-slice rendering in conjunction with a custom needle guide (3DUS + Epiguide). A clinical feasibility study evaluated the ability of 3DUS + Epiguide to identify the epidural needle puncture site for a midline insertion in the lumbar spine. We hypothesized that (i) the puncture site identified by 3DUS + Epiguide was within a 5-mm radius from the site chosen by standard palpation, and (ii) the difference between the two puncture sites was not correlated to the patient characteristics age, weight, height, body mass index and gestational age. The mean (±standard deviation) distances between puncture sites determined by 3DUS + Epiguide and palpation were 3.1 (±1.7) mm and 2.8 (±1.3) mm, for the L2-3 and L3-4 interspaces of 20 patients, respectively. Distances were comparable to intra-observer variability, indicating the potential for a thick-slice rendering of 3-D ultrasound along the Epiguide trajectory to select the puncture site of a midline neuraxial needle insertion. The long-term potential benefits of this system include increased efficiency and use of anesthesia, and a reduction in the frequency and severity of the complications from incorrect needle insertions. Epidural success in the most difficult cases (e.g., the obese) will be the focus of future work. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Simplified stereo-optical ultrasound plane calibration
NASA Astrophysics Data System (ADS)
Hoßbach, Martin; Noll, Matthias; Wesarg, Stefan
2013-03-01
Image guided therapy is a natural concept and commonly used in medicine. In anesthesia, a common task is the injection of an anesthetic close to a nerve under freehand ultrasound guidance. Several guidance systems exist using electromagnetic tracking of the ultrasound probe as well as the needle, providing the physician with a precise projection of the needle into the ultrasound image. This, however, requires additional expensive devices. We suggest using optical tracking with miniature cameras attached to a 2D ultrasound probe to achieve a higher acceptance among physicians. The purpose of this paper is to present an intuitive method to calibrate freehand ultrasound needle guidance systems employing a rigid stereo camera system. State of the art methods are based on a complex series of error prone coordinate system transformations which makes them susceptible to error accumulation. By reducing the amount of calibration steps to a single calibration procedure we provide a calibration method that is equivalent, yet not prone to error accumulation. It requires a linear calibration object and is validated on three datasets utilizing di erent calibration objects: a 6mm metal bar and a 1:25mm biopsy needle were used for experiments. Compared to existing calibration methods for freehand ultrasound needle guidance systems, we are able to achieve higher accuracy results while additionally reducing the overall calibration complexity. Ke
Ultrasound-Guided Cryoanalgesia of Peripheral Nerve Lesions.
Djebbar, Sahlya; Rossi, Ignacio M; Adler, Ronald S
2016-11-01
The real-time nature of ultrasound makes it ideally suited to provide guidance for a variety of musculoskeletal interventional procedures involving peripheral nerves. Continuous observation of the needle ensures proper placement and allows continuous monitoring when performing localized ablative therapy and therefore more accurate positioning of a cryoprobe, use of smaller needles, as well as access to small structures. We describe our experience performing cryoablative procedures. Patients undergoing cryoneurolysis have largely reported varying degrees of long-term pain relief and improvement in function; no serious complications have yet been identified. Ultrasound-guided cryoneurolysis can provide a useful, safe alternative to other ablative techniques to achieve long-term analgesia from painful peripheral nerve lesions. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Fürst, Rafael Vilhena de Carvalho; Polimanti, Afonso César; Galego, Sidnei José; Bicudo, Maria Claudia; Montagna, Erik; Corrêa, João Antônio
2017-03-01
To present a simple and affordable model able to properly simulate an ultrasound-guided venous access. The simulation was made using a latex balloon tube filled with water and dye solution implanted in a thawed chicken breast with bones. The presented model allows the simulation of all implant stages of a central catheter. The obtained echogenicity is similar to that observed in human tissue, and the ultrasound identification of the tissues, balloon, needle, wire guide and catheter is feasible and reproducible. The proposed model is simple, economical, easy to manufacture and capable of realistically and effectively simulating an ultrasound-guided venous access.
Bianchi, Simonetta; Bendinelli, Benedetta; Saladino, Valeria; Vezzosi, Vania; Brancato, Beniamino; Nori, Jacopo; Palli, Domenico
2015-07-01
One-hundred-fourteen consecutive cases of breast ultrasound-guided 14-gauge needle core biopsy (14G NCB) performed from January 2001 to June 2013 and diagnosed as non-malignant papillary lesion (PL)-B3, were reviewed and compared with definitive histological diagnosis on surgical excision (SE) to evaluate the diagnostic accuracy of ultrasound-guided 14G NCB. PL with epithelial atypia on 14G NCB were associated to malignancy on definitive histological diagnosis on SE in 22 (7 DCIS and 15 invasive carcinomas) of 46 cases with an underestimation rate of 47.8 %, while 9 (4 DCIS and 5 invasive carcinomas) cases out of 68 cases of PL without epithelial atypia were upgraded to carcinoma with an underestimation rate of 13.2 %. In cases of PL with epithelial atypia on ultrasound-guided 14G NCB, SE appears mandatory due to the high risk of associated malignancy. The diagnosis of PL without epithelial atypia on ultrasound-guided 14G NCB does not exclude malignancy at subsequent SE, consequently further assessment (by surgical or vacuum-assisted excision) is recommended to avoid the risk of delaying a diagnosis of malignancy, although this tends to be lower (1 in 8 patients).
Needle placement for piriformis injection using 3-D imaging.
Clendenen, Steven R; Candler, Shawn A; Osborne, Michael D; Palmer, Scott C; Duench, Stephanie; Glynn, Laura; Ghazi, Salim M
2013-01-01
Piriformis syndrome is a pain syndrome originating in the buttock and is attributed to 6% - 8% of patients referred for the treatment of back and leg pain. The treatment for piriformis syndrome using fluoroscopy, computed tomography (CT), electromyography (EMG), and ultrasound (US) has become standard practice. The treatment of Piriformis Syndrome has evolved to include fluoroscopy and EMG with CT guidance. We present a case study of 5 successful piriformis injections using 3-D computer-assisted electromagnet needle tracking coupled with ultrasound. A 6-degree of freedom electromagnetic position tracker was attached to the ultrasound probe that allowed the system to detect the position and orientation of the probe in the magnetic field. The tracked ultrasound probe was used to find the posterior superior iliac spine. Subsequently, 3 points were captured to register the ultrasound image with the CT or magnetic resonance image scan. Moreover, after the registration was obtained, the navigation system visualized the tracked needle relative to the CT scan in real-time using 2 orthogonal multi-planar reconstructions centered at the tracked needle tip. Conversely, a recent study revealed that fluoroscopically guided injections had 30% accuracy compared to ultrasound guided injections, which tripled the accuracy percentage. This novel technique exhibited an accurate needle guidance injection precision of 98% while advancing to the piriformis muscle and avoiding the sciatic nerve. The mean (± SD) procedure time was 19.08 (± 4.9) minutes. This technique allows for electromagnetic instrument tip tracking with real-time 3-D guidance to the selected target. As with any new technique, a learning curve is expected; however, this technique could offer an alternative, minimizing radiation exposure.
Feasibility of Prostate Cancer Diagnosis by Transrectal Photoacoustic Imaging
2012-03-01
cancer detection; needle biopsy is the current practice for diagnosis of the disease, aiming randomly in the prostate. Transrectal ultrasound has...been used as a guiding tool to direct tissue needle biopsy for prostate cancer diagnosis; it cannot be utilized for detecting prostate cancer due to...Research Systems, CA) and used as a reference signal. The sample and the ultrasound transducer (UST, Olympus NDT, one inch in focal length) are
Mainiero, Martha B
2010-09-01
The status of axillary lymph nodes is a key prognostic indicator in patients with breast cancer and helps guide patient management. Sentinel lymph node biopsy is increasingly being used as a less morbid alternative to axillary lymph node dissection. However, when sentinel lymph node biopsy is positive, axillary dissection is typically performed for complete staging and local control. Axillary ultrasound and ultrasound-guided fine needle aspiration (USFNA) are useful for detecting axillary nodal metastasis preoperatively and can spare patients sentinel node biopsy, because those with positive cytology on USFNA can proceed directly to axillary dissection or neoadjuvant chemotherapy. Internal mammary nodes are not routinely evaluated, but when the appearance of these nodes is abnormal on imaging, further treatment or metastatic evaluation may be necessary. Copyright © 2010 Elsevier Inc. All rights reserved.
Kallidaikurichi Srinivasan, Karthikeyan; Iohom, Gabriella; Loughnane, Frank; Lee, Peter J
2015-10-01
Multiple passes and attempts while administering spinal anesthesia are associated with a greater incidence of postdural puncture headache, paraesthesia, and spinal hematoma. We hypothesized that the routine use of a preprocedural ultrasound-guided paramedian technique for spinal anesthesia would reduce the number of passes required to achieve entry into the subarachnoid space when compared with the conventional landmark-guided midline approach. One hundred consenting patients scheduled for elective total joint replacements (hip and knee) were randomized into group C (conventional) and group P (preprocedural ultrasound-guided paramedian technique) with 50 in each group. The patients were blinded to the study group. All spinal anesthetics were administered by a consultant anesthesiologist. In group C, spinal anesthetic was done via the midline approach using clinically palpated landmarks. In group P, a preprocedural ultrasound scan was used to mark the paramedian insertion site, and spinal anesthetic was performed via the paramedian approach. The average number of passes (defined as the number of forward advancements of the spinal needle in a given interspinous space, i.e., withdrawal and redirection of spinal needle without exiting the skin) in group P was approximately 0.34 times that in group C, a difference that was statistically significant (P = 0.01). Similarly, the average number of attempts (defined as the number of times the spinal needle was withdrawn from the skin and reinserted) in group P was approximately 0.25 times that of group C (P = 0.0021). In group P, on an average, it took 81.5 (99% confidence interval, 68.4-97 seconds) seconds longer to identify the landmarks than in group C (P = 0.0002). All other parameters, including grading of palpated landmarks, time taken for spinal anesthetic injection, periprocedural pain scores, periprocedural patient discomfort visual analog scale score, conversion to general anesthetic, paresthesia, and radicular pain during needle insertion, were similar between the 2 groups. Routine use of paramedian spinal anesthesia in the orthopedic patient population undergoing joint replacement surgery, guided by preprocedure ultrasound examination, significantly decreases the number of passes and attempts needed to enter the subarachnoid space.
Polkowski, M; Larghi, A; Weynand, B; Boustière, C; Giovannini, M; Pujol, B; Dumonceau, J-M
2012-02-01
This article is the second of a two-part publication that expresses the current view of the European Society of Gastrointestinal Endoscopy (ESGE) about endoscopic ultrasound (EUS)-guided sampling, including EUS-guided fine needle aspiration (EUS-FNA) and EUS-guided Trucut biopsy. The first part (the Clinical Guideline) focused on the results obtained with EUS-guided sampling, and the role of this technique in patient management, and made recommendations on circumstances that warrant its use. The current Technical Guideline discusses issues related to learning, techniques, and complications of EUS-guided sampling, and to processing of specimens. Technical issues related to maximizing the diagnostic yield (e.g., rapid on-site cytopathological evaluation, needle diameter, microcore isolation for histopathological examination, and adequate number of needle passes) are discussed and recommendations are made for various settings, including solid and cystic pancreatic lesions, submucosal tumors, and lymph nodes. The target readership for the Clinical Guideline mostly includes gastroenterologists, oncologists, internists, and surgeons while the Technical Guideline should be most useful to endoscopists who perform EUS-guided sampling. A two-page executive summary of evidence statements and recommendations is provided. © Georg Thieme Verlag KG Stuttgart · New York.
Batllori, M; Urra, M; Uriarte, E; Romero, C; Pueyo, J; López-Olaondo, L; Cambra, K; Ibáñez, B
2016-03-01
Ultrasound-guided internal jugular venous access increases the rate of successful cannulation and reduces the incidence of complications, compared with the landmark technique. Three transducer orientation approaches have been proposed for this procedure: short-axis (SAX), long-axis (LAX) and oblique-axis (OAX). Our goal was to assess and compare the performance of these approaches. A prospective randomized clinical trial was conducted in one teaching hospital. Patients aged 18 yr or above, who were undergoing ultrasound-guided internal jugular cannulation, were randomly assigned to one of three intervention groups: SAX, LAX and OAX group. The main outcome measure was successful cannulation on first needle pass. Incidence of mechanical complications was also registered. Restricted randomization was computer-generated. In total, 220 patients were analysed (SAX n=73, LAX n=75, OAX n=72). Cannulation was successful on first needle pass in 51 (69.9%) SAX patients, 39 (52%) LAX patients and 53 (73.6%) OAX patients. First needle pass failure was higher in the LAX group than in the OAX group (adjusted OR 3.7, 95% CI 1.71-8.0, P=0.002). A higher mechanical complication rate was observed in the SAX group (15.1%) than in the OAX (6.9%) and LAX (4%) groups (P=0.047). As OAX showed a higher first needle pass success rate than LAX and a lower mechanical complications rate than SAX, we recommend it as the standard approach when performing ultrasound-guided internal jugular venous access. Further clinical studies are needed to confirm this conclusion. NCT 01966354. © The Author 2015. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Ultrasound-guided, minimally invasive, percutaneous needle puncture treatment for tennis elbow.
Zhu, Jiaan; Hu, Bing; Xing, Chunyan; Li, Jia
2008-10-01
This report evaluates the efficacy of percutaneous needle puncture under sonographic guidance in treating lateral epicondylitis (tennis-elbow). Ultrasound-guided percutaneous needle puncture was performed on 76 patients who presented with persistent elbow pain. Under a local anesthetic and sonographic guidance, a needle was advanced into the calcification foci and the calcifications were mechanically fragmented. This was followed by a local injection of 25 mg prednisone acetate and 1% lidocaine. If no calcification was found then multiple punctures were performed followed by local injection of 25 mg prednisone acetate and 1% lidocaine. A visual analog scale (VAS) was used to evaluate the degree of pain pre-and posttreatment at 1 week to 24 weeks. Elbow function improvement and degree of self-satisfaction were also evaluated. Of the 76 patients, 55% were rated with excellent treatment outcome, 32% good, 11% average, and 3% poor. From 3 weeks posttreatment, VAS scores were significantly reduced compared with the pretreatment score (P<0.05) and continued to gradually decline up to 24 weeks posttreatment. Sonography demonstrated that the calcified lesions disappeared completely in 13% of the patients, were reduced in 61% of the patients, and did not change in 26% of the patients. Color Doppler flow signal used to assess hemodynamic changes showed a significant improvement after treatment in most patients. Ultrasound-guided percutaneous needle puncture is an effective and minimally invasive treatment for tennis elbow. Sonography can be used to accurately identify the puncture location and monitor changes.
da Cunha Santos, G; Saieg, M A; Troncone, G; Zeppa, P
2018-04-01
Minimally invasive procedures such as endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) must yield not only good quality and quantity of material for morphological assessment, but also an adequate sample for analysis of molecular markers to guide patients to appropriate targeted therapies. In this context, cytopathologists worldwide should be familiar with minimum requirements for refereeing cytological samples for testing. The present manuscript is a review with comprehensive description of the content of the workshop entitled Cytological preparations for molecular analysis: pre-analytical issues for EBUS TBNA, presented at the 40th European Congress of Cytopathology in Liverpool, UK. The present review emphasises the advantages and limitations of different types of cytology substrates used for molecular analysis such as archival smears, liquid-based preparations, archival cytospin preparations and FTA (Flinders Technology Associates) cards, as well as their technical requirements/features. These various types of cytological specimens can be successfully used for an extensive array of molecular studies, but the quality and quantity of extracted nucleic acids rely directly on adequate pre-analytical assessment of those samples. In this setting, cytopathologists must not only be familiar with the different types of specimens and associated technical procedures, but also correctly handle the material provided by minimally invasive procedures, ensuring that there is sufficient amount of material for a precise diagnosis and correct management of the patient through personalised care. © 2018 John Wiley & Sons Ltd.
Cancer Localization in the Prostate with F-18 Fluorocholine Positron Emission Tomography
2007-01-01
INTRODUCTION Prostate cancer is the second leading cause of cancer death in American men over 50 years of age. Ultrasound - guided prostate biopsy is...currently the most common method for diagnosing and localizing cancer in the prostate. However, even when standard 6 or 12 needle biopsy templates... needles employed (1, 2). While progress has been made in the detection of primary prostate cancer using imaging techniques such as ultrasound and
Mikosiński, Sławomir; Pomorski, Lech; Oszukowska, Lidia; Makarewicz, Jacek; Adamczewski, Zbigniew; Sporny, Stanisław; Lewiński, Andrzej
2006-01-01
Recurrent differentiated thyroid cancer generally occurs first in the neck. Ultrasound is sensitive in detecting enlarged cervical lymph nodes but is not specific enough. Ultrasound-guided fine-needle biopsy increases the specificity but still may fail to detect a recurrence of the disease in the cystic metastatic lymph nodes. The aim of the study was to estimate the value of Tg concentration in the needle washout after fine-needle aspiration of suspicious lymph nodes. The 105 patients studied had presented one or more enlarged suspicious cervical lymph nodes. All had undergone total thyroidectomy and (131)I ablative therapy. Serum thyroglobulin (Tg) concentration was within the 0.15-711.5 ng/ml range (mean 22.24 ng/ml) and Tg recovery range 94-100%. The positive Tg washout concentration cut-off value was established as equal to the mean plus two standard deviations of the Tg washout concentration of patients with negative cytology. Lymph node involvement was diagnosed by cytology in 15 patients and in 28 lymph nodes. Positive Tg washout concentration was found in 22 patients and in 48 lymph nodes. All the lymph nodes which turned out to have positive cytology had a positive Tg washout concentration. All lymph nodes with positive cytology were positive in pathology. Seven patients and 20 lymph nodes with negative cytology were positive in the Tg washout concentration test. All but one patients and all but two lymph nodes with a positive Tg washout concentration had positive pathology. 1. Ultrasound-guided fine-needle biopsy is not sensitive enough to detect all metastatic lymph nodes. 2. The Tg washout concentration test is 100% sensitive in the detection of metastatic lymph nodes. 3. Cytology in ultrasound- guided fine-needle biopsy is 100% specific. 4. The Tg washout concentration test carries a risk of false-positive results. 5. Both methods should be used for early detection of metastatic lymph nodes in patients with differentiated thyroid cancer.
Stack, John David; Bergamino, Chiara; Sanders, Ruth; Fogarty, Ursula; Puggioni, Antonella; Kearney, Clodagh; David, Florent
2016-09-20
To compare the accuracy and distribution of injectate for cranial (CR) and caudomedial (CM) ultrasound-guided injections of equine sacroiliac joints. Both sacroiliac joints from 10 lumbosacropelvic specimens were injected using cranial parasagittal (CR; curved 18 gauge, 25 cm spinal needles) and caudomedial (CM; straight 18 gauge, 15 cm spinal needles) ultrasound-guided approaches. Injectate consisted of 4 ml iodinated contrast and 2 ml methylene blue. Computed tomographical (CT) scans were performed before and after injections. Time for needle guidance and repositioning attempts were recorded. The CT sequences were analysed for accuracy and distribution of contrast. Intra-articular contrast was detected in sacroiliac joints following 15/40 injections. The CR and CM approaches deposited injectate ≤2 cm from sacroiliac joint margins following 17/20 and 20/20 injections, respectively. Median distance of closest contrast to the sacroiliac joint was 0.4 cm (interquartile range [IQR]: 1.5 cm) for CR approaches and 0.6 cm (IQR: 0.95 cm) for CM approaches. Cranial injections resulted in injectate contacting lumbosacral intertransverse joints 15/20 times. Caudomedial injections were perivascular 16/20 times. Safety and efficacy could not be established. Cranial and CM ultrasound-guided injections targeting sacroiliac joints were very accurate for periarticular injection, but accuracy was poor for intra-articular injection. Injectate was frequently found in contact with interosseous sacroiliac ligaments, as well as neurovascular and synovial structures in close vicinity of sacroiliac joints.
Chung, Ho Seok; Hwang, Eu Chang; Yu, Ho Song; Jung, Seung Il; Lee, Sun Ju; Lim, Dong Hoon; Cho, Won Jin; Choe, Hyun Sop; Lee, Seung-Ju; Park, Sung Woon
2018-03-01
To estimate the prevalence of fluoroquinolone-resistant rectal flora in patients undergoing transrectal ultrasound-guided prostate needle biopsy and to identify the high-risk groups. From January 2015 to March 2016, rectal swabs of 557 men who underwent transrectal ultrasound-guided prostate needle biopsy were obtained from five institutions. Clinical variables, including demographics, rectal swab culture results and infectious complications, were evaluated. Univariable and multivariable analyses were used to identify the risk factors for fluoroquinolone resistance of rectal flora and infectious complications. The incidence of fluoroquinolone-resistant and extended-spectrum beta-lactamase production was 48.1 and 11.8%, respectively. The most common fluoroquinolone-resistant bacteria was Escherichia coli (81% of total fluoroquinolone-resistant bacteria, 39% of total rectal flora), and 16 (2.9%) patients had infectious complications. Univariable and multivariable analysis of clinical parameters affecting fluoroquinolone resistance showed no factor associated with fluoroquinolone resistance of rectal flora. The clinical parameter related to infectious complications after prostate biopsy was a history of operation within 6 months (relative risk 6.60; 95% confidence interval 1.99-21.8, P = 0.002). These findings suggest that a risk-based approach by history taking cannot predict antibiotic resistance of rectal flora, and physicians should consider targeted antibiotic prophylaxis or extended antibiotic prophylaxis for Korean patients undergoing transrectal ultrasound-guided prostate biopsy because of high antibiotic resistance of rectal flora. © 2017 The Japanese Urological Association.
Ultrasound-guided thermocouple placement for cryosurgery.
Abramovits, W; Pruiksma, R; Bose, S
1996-09-01
Although cryosurgical methods have high cure rates, imprecise estimates of both skin lesion depth and destructive temperature front location result in subjective technique in skin malignancy treatments. We evaluated the possibility of newer ultrasound equipment to assist in the precise placement of thermocouples in human skin. DermaScan C ver. 3 ultrasonographic equipment fitted with a sharp focus probe with a frequency of 20 MHz and a scan length of 12.1 mm was used to locate thermocouples with 27- and 30-gauge needles. We successfully and reproducibly located thermocouples and thin needles, and accurately measured their distance from the skin surface. Ultrasound is a useful method for the accurate placement of thermocouples, and needles as thin as 30 gauge for monitoring in cryosurgery.
Allam, Abdallah El-Sayed; Khalil, Adham Aboul Fotouh; Eltawab, Basma Aly; Wu, Wei-Ting
2018-01-01
Orofacial myofascial pain is prevalent and most often results from entrapment of branches of the trigeminal nerves. It is challenging to inject branches of the trigeminal nerve, a large portion of which are shielded by the facial bones. Bony landmarks of the cranium serve as important guides for palpation-guided injections and can be delineated using ultrasound. Ultrasound also provides real-time images of the adjacent muscles and accompanying arteries and can be used to guide the needle to the target region. Most importantly, ultrasound guidance significantly reduces the risk of collateral injury to vital neurovascular structures. In this review, we aimed to summarize the regional anatomy and ultrasound-guided injection techniques for the trigeminal nerve and its branches, including the supraorbital, infraorbital, mental, auriculotemporal, maxillary, and mandibular nerves. PMID:29808105
Backscattering analysis of high frequency ultrasonic imaging for ultrasound-guided breast biopsy
NASA Astrophysics Data System (ADS)
Cummins, Thomas; Akiyama, Takahiro; Lee, Changyang; Martin, Sue E.; Shung, K. Kirk
2017-03-01
A new ultrasound-guided breast biopsy technique is proposed. The technique utilizes conventional ultrasound guidance coupled with a high frequency embedded ultrasound array located within the biopsy needle to improve the accuracy in breast cancer diagnosis.1 The array within the needle is intended to be used to detect micro- calcifications indicative of early breast cancers such as ductal carcinoma in situ (DCIS). Backscattering analysis has the potential to characterize tissues to improve localization of lesions. This paper describes initial results of the application of backscattering analysis of breast biopsy tissue specimens and shows the usefulness of high frequency ultrasound for the new biopsy related technique. Ultrasound echoes of ex-vivo breast biopsy tissue specimens were acquired by using a single-element transducer with a bandwidth from 41 MHz to 88 MHz utilizing a UBM methodology, and the backscattering coefficients were calculated. These values as well as B-mode image data were mapped in 2D and matched with each pathology image for the identification of tissue type for the comparison to the pathology images corresponding to each plane. Microcalcifications were significantly distinguished from normal tissue. Adenocarcinoma was also successfully differentiated from adipose tissue. These results indicate that backscattering analysis is able to quantitatively distinguish tissues into normal and abnormal, which should help radiologists locate abnormal areas during the proposed ultrasound-guided breast biopsy with high frequency ultrasound.
Alatawi, Abdullah; Beuvon, Frédéric; Grabar, Sophie; Leblanc, Sarah; Chaussade, Stanislas; Terris, Benoit; Barret, Maximilien
2015-01-01
Objectives Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) using standard needles has a high diagnostic value in the evaluation of solid pancreatic masses. Fenestrated needles have been developed to improve the quality of EUS-guided tissue sampling by providing core biopsies (FNB). Methods Patients with solid pancreatic masses of >2 cm were prospectively included in our study and randomized to receive EUS sampling, using either a standard 22G FNA or a 22G Procore® FNB needle. The main study endpoint was the number of needle passes required to obtain a diagnosis in more than 90% of cases. Results We included 100 patients (male = 63, female = 37; mean age = 68.4 years) in our study. We found that 88% of the lesions were malignant, with a mean size of 32 mm. A sample adequate for diagnosis was obtained in more than 90% of cases after the second needle pass in the FNB group, versus the third needle pass in the FNA group. Slide cellularity and presence of tissue microfragments were significantly higher in the FNB group. Sensitivity for the diagnosis of malignancy was 88.4% versus 97.8% for the EUS-FNA and EUS-FNB group, respectively, while specificity for both techniques was 100%. No complications were recorded. Conclusions Although the accuracy of both needle types for proving malignancy was similar, a lower number of passes was required with the FNB needles to achieve the same contributive sample rate as with the FNA needles. FNB also improved the histopathological quality of specimens, suggesting an overall superiority of FNB sampling. PMID:26279842
Benchmarking of state-of-the-art needle detection algorithms in 3D ultrasound data volumes
NASA Astrophysics Data System (ADS)
Pourtaherian, Arash; Zinger, Svitlana; de With, Peter H. N.; Korsten, Hendrikus H. M.; Mihajlovic, Nenad
2015-03-01
Ultrasound-guided needle interventions are widely practiced in medical diagnostics and therapy, i.e. for biopsy guidance, regional anesthesia or for brachytherapy. Needle guidance using 2D ultrasound can be very challenging due to the poor needle visibility and the limited field of view. Since 3D ultrasound transducers are becoming more widely used, needle guidance can be improved and simplified with appropriate computer-aided analyses. In this paper, we compare two state-of-the-art 3D needle detection techniques: a technique based on line filtering from literature and a system employing Gabor transformation. Both algorithms utilize supervised classification to pre-select candidate needle voxels in the volume and then fit a model of the needle on the selected voxels. The major differences between the two approaches are in extracting the feature vectors for classification and selecting the criterion for fitting. We evaluate the performance of the two techniques using manually-annotated ground truth in several ex-vivo situations of different complexities, containing three different needle types with various insertion angles. This extensive evaluation provides better understanding on the limitations and advantages of each technique under different acquisition conditions, which is leading to the development of improved techniques for more reliable and accurate localization. Benchmarking results that the Gabor features are better capable of distinguishing the needle voxels in all datasets. Moreover, it is shown that the complete processing chain of the Gabor-based method outperforms the line filtering in accuracy and stability of the detection results.
Udani, Ankeet D; Harrison, T Kyle; Howard, Steven K; Kim, T Edward; Brock-Utne, John G; Gaba, David M; Mariano, Edward R
2012-08-01
A head-mounted display provides continuous real-time imaging within the practitioner's visual field. We evaluated the feasibility of using head-mounted display technology to improve ergonomics in ultrasound-guided regional anesthesia in a simulated environment. Two anesthesiologists performed an equal number of ultrasound-guided popliteal-sciatic nerve blocks using the head-mounted display on a porcine hindquarter, and an independent observer assessed each practitioner's ergonomics (eg, head turning, arching, eye movements, and needle manipulation) and the overall block quality based on the injectate spread around the target nerve for each procedure. Both practitioners performed their procedures without directly viewing the ultrasound monitor, and neither practitioner showed poor ergonomic behavior. Head-mounted display technology may offer potential advantages during ultrasound-guided regional anesthesia.
Srinivasan, Karthikeyan Kallidaikurichi; Leo, Anne-Marie; Iohom, Gabriella; Loughnane, Frank; Lee, Peter J
2018-01-01
Background and Aims: Routine use of pre-procedural ultrasound guided midline approach has not shown to improve success rate in administering subarachnoid block. The study hypothesis was that the routine use of pre-procedural (not real time) ultrasound-guided paramedian spinals at L5-S1 interspace could reduce the number of passes (i.e., withdrawal and redirection of spinal needle without exiting the skin) required to enter the subarachnoid space when compared to the conventional landmark-guided midline approach. Methods: After local ethics approval, 120 consenting patients scheduled for elective total joint replacements (Hip and Knee) were randomised into either Group C where conventional midline approach with palpated landmarks was used or Group P where pre-procedural ultrasound was used to perform subarachnoid block by paramedian approach at L5-S1 interspace (real time ultrasound guidance was not used). Results: There was no difference in primary outcome (difference in number of passes) between the two groups. Similarly there was no difference in the number of attempts (i.e., the number of times the spinal needle was withdrawn from the skin and reinserted). The first pass success rates (1 attempt and 1 pass) was significantly greater in Group C compared to Group P [43% vs. 22%, P = 0.02]. Conclusion: Routine use of paramedian spinal anaesthesia at L5-S1 interspace, guided by pre-procedure ultrasound, in patients undergoing lower limb joint arthroplasties did not reduce the number of passes or attempts needed to achieve successful dural puncture. PMID:29416151
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hrinivich, Thomas; Hoover, Douglas; Surry, Kathlee
Ultrasound-guided high-dose-rate prostate brachytherapy (HDR-BT) needle segmentation is performed clinically using live-2D sagittal images. Organ segmentation is then performed using axial images, introducing a source of geometric uncertainty. Sagittally-reconstructed 3D (SR3D) ultrasound enables both needle and organ segmentation, but suffers from shadow artifacts. We present a needle segmentation technique augmenting SR3D with live-2D sagittal images using mechanical probe tracking to mitigate image artifacts and compare it to the clinical standard. Seven prostate cancer patients underwent TRUS-guided HDR-BT during which the clinical and proposed segmentation techniques were completed in parallel using dual ultrasound video outputs. Calibrated needle end-length measurements were usedmore » to calculate insertion depth errors (IDEs), and the dosimetric impact of IDEs was evaluated by perturbing clinical treatment plan source positions. The proposed technique provided smaller IDEs than the clinical approach, with mean±SD of −0.3±2.2 mm and −0.5±3.7mm respectively. The proposed and clinical techniques resulted in 84% and 43% of needles with IDEs within ±3mm, and IDE ranges across all needles of [−7.7mm, 5.9mm] and [−9.3mm, 7.7mm] respectively. The proposed and clinical IDEs lead to mean±SD changes in the volume of the prostate receiving the prescription dose of −0.6±0.9% and −2.0±5.3% respectively. The proposed technique provides improved HDR-BT needle segmentation accuracy over the clinical technique leading to decreased dosimetric uncertainty by eliminating the axial-to-sagittal registration, and mitigates the effect of shadow artifacts by incorporating mechanically registered live-2D sagittal images.« less
Convolution neural networks for real-time needle detection and localization in 2D ultrasound.
Mwikirize, Cosmas; Nosher, John L; Hacihaliloglu, Ilker
2018-05-01
We propose a framework for automatic and accurate detection of steeply inserted needles in 2D ultrasound data using convolution neural networks. We demonstrate its application in needle trajectory estimation and tip localization. Our approach consists of a unified network, comprising a fully convolutional network (FCN) and a fast region-based convolutional neural network (R-CNN). The FCN proposes candidate regions, which are then fed to a fast R-CNN for finer needle detection. We leverage a transfer learning paradigm, where the network weights are initialized by training with non-medical images, and fine-tuned with ex vivo ultrasound scans collected during insertion of a 17G epidural needle into freshly excised porcine and bovine tissue at depth settings up to 9 cm and [Formula: see text]-[Formula: see text] insertion angles. Needle detection results are used to accurately estimate needle trajectory from intensity invariant needle features and perform needle tip localization from an intensity search along the needle trajectory. Our needle detection model was trained and validated on 2500 ex vivo ultrasound scans. The detection system has a frame rate of 25 fps on a GPU and achieves 99.6% precision, 99.78% recall rate and an [Formula: see text] score of 0.99. Validation for needle localization was performed on 400 scans collected using a different imaging platform, over a bovine/porcine lumbosacral spine phantom. Shaft localization error of [Formula: see text], tip localization error of [Formula: see text] mm, and a total processing time of 0.58 s were achieved. The proposed method is fully automatic and provides robust needle localization results in challenging scanning conditions. The accurate and robust results coupled with real-time detection and sub-second total processing make the proposed method promising in applications for needle detection and localization during challenging minimally invasive ultrasound-guided procedures.
Lovely, Lyndsay M; Chishti, Yasmin Z; Woodland, Jennifer L; Lalonde, Donald H
2018-05-01
Many surgeons and emergentologists use non-ultrasound-guided wrist nerve blocks. There is little evidence to guide the ideal volume of local anesthesia or how long we should wait after injection before performing pain-free procedures. This pilot study examined time to maximal anesthesia to painful needle stick in 14 volunteer participants receiving bilateral wrist blocks of 6 versus 11 mL of local. One surgeon performed all 14 bilateral wrist median nerve blocks in participants who remained blinded until after bandages were applied to their wrist. No one could see which wrist received the larger 11-mL volume injection versus the 6-mL block. Blinded sensory assessors then measured perceived maximal numbness time and numbness to needle stick pain in the fingertips of the median nerve distribution. Failure to get a complete median nerve block occurred in seven of fourteen 6-mL wrist blocks versus failure in only one of fourteen 11-mL blocks. Perceived maximal numbness occurred at roughly 40 minutes after injection, but actual numbness to painful needle stick took around 100 minutes. Incomplete median nerve numbness occurred with both 6- and 11-mL non-ultrasound-guided blocks at the wrist. In those with complete blocks, it took a surprisingly long time of 100 minutes for maximal anesthesia to occur to painful needle stick stimuli to the fingertips of the median nerve distribution. Non-ultrasound-guided median nerve blocks at the wrist as described in this article lack reliability and take too long to work.
Wagner, Jason M; Conrad, Rachel D; Cannon, Trinitia Y; Alleman, Anthony M
2016-05-01
Limited data exist regarding the feasibility of ultrasound-guided transcutaneous biopsy of the base of the tongue and floor of the mouth. This retrospective study reviewed 8 cases with lesions in the base of the tongue or floor of the mouth that were biopsied by fine-needle aspiration. Core biopsy was also needed in 1 case. All biopsies were technically successful, and all yielded squamous cell carcinoma. One biopsy yielded a false-positive result, as subsequent resection yielded high-grade dysplasia with no invasion. The other biopsy results were considered true-positive based on subsequent pathologic examinations (2 cases) or clinical/imaging follow-up (5 cases). There were no significant complications associated with the biopsies. © 2016 by the American Institute of Ultrasound in Medicine.
Vrooijink, Gustaaf J.; Abayazid, Momen; Patil, Sachin; Alterovitz, Ron; Misra, Sarthak
2015-01-01
Needle insertion is commonly performed in minimally invasive medical procedures such as biopsy and radiation cancer treatment. During such procedures, accurate needle tip placement is critical for correct diagnosis or successful treatment. Accurate placement of the needle tip inside tissue is challenging, especially when the target moves and anatomical obstacles must be avoided. We develop a needle steering system capable of autonomously and accurately guiding a steerable needle using two-dimensional (2D) ultrasound images. The needle is steered to a moving target while avoiding moving obstacles in a three-dimensional (3D) non-static environment. Using a 2D ultrasound imaging device, our system accurately tracks the needle tip motion in 3D space in order to estimate the tip pose. The needle tip pose is used by a rapidly exploring random tree-based motion planner to compute a feasible needle path to the target. The motion planner is sufficiently fast such that replanning can be performed repeatedly in a closed-loop manner. This enables the system to correct for perturbations in needle motion, and movement in obstacle and target locations. Our needle steering experiments in a soft-tissue phantom achieves maximum targeting errors of 0.86 ± 0.35 mm (without obstacles) and 2.16 ± 0.88 mm (with a moving obstacle). PMID:26279600
In-plane ultrasonic needle tracking using a fiber-optic hydrophone
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xia, Wenfeng, E-mail: wenfeng.xia@ucl.ac.uk; Desjardins, Adrien E.; Mari, Jean Martial
Purpose: Accurate and efficient guidance of needles to procedural targets is critically important during percutaneous interventional procedures. Ultrasound imaging is widely used for real-time image guidance in a variety of clinical contexts, but with this modality, uncertainties about the location of the needle tip within the image plane lead to significant complications. Whilst several methods have been proposed to improve the visibility of the needle, achieving accuracy and compatibility with current clinical practice is an ongoing challenge. In this paper, the authors present a method for directly visualizing the needle tip using an integrated fiber-optic ultrasound receiver in conjunction withmore » the imaging probe used to acquire B-mode ultrasound images. Methods: Needle visualization and ultrasound imaging were performed with a clinical ultrasound imaging system. A miniature fiber-optic ultrasound hydrophone was integrated into a 20 gauge injection needle tip to receive transmissions from individual transducer elements of the ultrasound imaging probe. The received signals were reconstructed to create an image of the needle tip. Ultrasound B-mode imaging was interleaved with needle tip imaging. A first set of measurements was acquired in water and tissue ex vivo with a wide range of insertion angles (15°–68°) to study the accuracy and sensitivity of the tracking method. A second set was acquired in an in vivo swine model, with needle insertions to the brachial plexus. A third set was acquired in an in vivo ovine model for fetal interventions, with insertions to different locations within the uterine cavity. Two linear ultrasound imaging probes were used: a 14–5 MHz probe for the first and second sets, and a 9–4 MHz probe for the third. Results: During insertions in tissue ex vivo and in vivo, the imaged needle tip had submillimeter axial and lateral dimensions. The signal-to-noise (SNR) of the needle tip was found to depend on the insertion angle. With the needle tip in water, the SNR of the needle tip varied with insertion angle, attaining values of 284 at 27° and 501 at 68°. In swine tissue ex vivo, the SNR decreased from 80 at 15° to 16 at 61°. In swine tissue in vivo, the SNR varied with depth, from 200 at 17.5 mm to 48 at 26 mm, with a constant insertion angle of 40°. In ovine tissue in vivo, within the uterine cavity, the SNR varied from 46.4 at 25 mm depth to 18.4 at 32 mm depth, with insertion angles in the range of 26°–65°. Conclusions: A fiber-optic ultrasound receiver integrated into the needle cannula in combination with single-element transmissions from the imaging probe allows for direct visualization of the needle tip within the ultrasound imaging plane. Visualization of the needle tip was achieved at depths and insertion angles that are encountered during nerve blocks and fetal interventions. The method presented in this paper has strong potential to improve the safety and efficiency of ultrasound-guided needle insertions.« less
Therapeutic aspects of endoscopic ultrasound
NASA Astrophysics Data System (ADS)
Woodward, Timothy A.
1999-06-01
Endoscopic ultrasound (EUS) is a technology that had been used primarily as a passive imaging modality. Recent advances have enabled us to move beyond the use of EUS solely as a staging tool to an interventional device. Current studies suggest that interventional applications of EUS will allow for minimally invasive assessment and therapies in a cost-effective manner. Endoscopic ultrasound with fine needle aspiration (EUS-FNA) has been demonstrated to be a technically feasible, relatively safe method of obtaining cytologic specimens. The clinical utility of EUS- FNA appears to be greatest in the diagnosis and staging of pancreatic cancer and in the nodal staging of gastrointestinal and pulmonary malignancies. In addition, EUS-FNA has demonstrated utility in the sampling pleural and ascitic fluid not generally appreciated or assessable to standard interventions. Interventional applications of EUS include EUS-guided pseudocyst drainage, EUS-guided injection of botulinum toxin in the treatment of achalasia, and EUS- guided celiac plexus neurolysis in the treatment of pancreatic cancer pain. Finally, EUS-guided fine-needle installation is being evaluated, in conjunction with recent bimolecular treatment modalities, as a delivery system in the treatment of certain gastrointestinal tumors.
Scholten, Paul M; Massimi, Stephen; Dahmen, Nick; Diamond, Joanne; Wyss, James
2015-01-01
Athletic pubalgia is a syndrome of persistent groin pain due to chronic repetitive trauma or stress involving the pelvic joints and many musculotendinous structures that cross the anterior pelvis. As a result, the differential diagnosis can be complex, but insertional tendinopathies are the most common. This case report describes a novel approach to the treatment of distal rectus abdominis tendinopathies with ultrasound-guided needle tenotomy and platelet-rich plasma (PRP) injection. After injection, the patient returned to pain-free play at his previous level of intensity. This suggests that PRP may be a useful treatment for this diagnosis. Copyright © 2015. Published by Elsevier Inc.
Isolated splenic tuberculosis diagnosed by endoscopic ultrasound-guided fine needle aspiration.
Nasa, Mukesh; Choudhary, Narendra S; Guleria, Mridula; Puri, Rajesh
2017-04-01
Our patient was a 48-year-old female, who presented with history of persistent low-grade fever and weight loss. The CT scan of the abdomen revealed multiple hypodense lesions in spleen. No primary focus of infection was detected in any other organs. Endoscopic ultrasound-guided fine needle aspiration of splenic lesion revealed granulomatous inflammation. The patient was started on anti-tuberculous therapy. There is a diagnostic possibility of splenic tuberculosis even in immunocompetent individuals and we chose a combination anti-tuberculous therapy as the first line treatment with consideration of splenectomy depending on the response. Copyright © 2016 Tuberculosis Association of India. Published by Elsevier B.V. All rights reserved.
Purefoy Johnson, Jessica; Stack, John David; Rowan, Conor; Handel, Ian; O'Leary, John Mark
2017-05-22
To compare accuracy of the ultrasound-guided craniodorsal (CrD) approach with the dorsal (D) approach to the cervical articular process joints, and to evaluate the effect of the transducer, needle gauge, and operator experience. Cervical articular process joints from 14 cadaveric neck specimens were injected using either a D or CrD approach, a linear (13 MHx) or microconvex transducer (10 MHz), and an 18 or 20 gauge needle, by an experienced or inexperienced operator. Injectate consisted of an iodinated contrast material solution. Time taken for injection, number of redirects, and retrieval of synovial fluid were recorded. Accuracy was assessed using a scoring system for contrast seen on computed tomography (CT). The successful performance of intra-articular injections of contrast detected by CT using the D (61/68) and CrD (57/64) approaches was comparable. No significant effect of approach, transducer or needle gauge was observed on injection accuracy, time taken to perform injection, or number of redirects. The 18 gauge needle had a positive correlation with retrieval of synovial fluid. A positive learning curve was observed for the inexperienced operator. Both approaches to the cervical articular process joints were highly accurate. Ultrasound-guided injection of the cervical articular process joints is an easily-learnt technique for an inexperienced veterinarian. Either approach may be employed in the field with a high level of accuracy, using widely available equipment.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Caturelli, Eugenio; Biasini, Elisabetta; Bartolucci, Francesca
2002-08-15
Purpose: To evaluate the utility of a second ultrasound-guided fine-needle biopsy of liver nodules thought to be hepatocellular carcinoma when the original biopsy has failed to provide a reliable diagnosis. Methods: Thirty-seven cirrhotic patients underwent ultrasound-guided fine-needle biopsy of liver nodules that were subsequently diagnosed as hepatocellular carcinoma. Each biopsy involved a single puncture with a 20 G cutting needle, which yielded pathologic material used both for cytologic and histologic studies. In 23 cases (mean diameter of nodules 48 mm) the biopsy furnished exclusively necrotic material (non-diagnostic subgroup); in the other 14 cases (mean diameter 26 mm) the biopsy yieldedmore » no neoplastic elements (false-negative subgroup). All 37 nodules were subjected to repeat biopsies performed in the same manner. Results: The repeat biopsies provided a diagnosis of hepatocellular carcinoma in six of the 23 patients from the non-diagnostic subgroup and in seven of the 14 in the false-negative subgroup. Overall, repeat biopsy produced a diagnostic gain of 35.1%. Conclusion: The chance of success with repeat biopsy of hepatocellular carcinoma is limited and may depend to some extent on the characteristics of the lesions (i.e., areas of necrosis in large nodules, well-differentiated cellular populations in small ones)« less
Lourido-Cebreiro, Tamara; Leiro-Fernández, Virginia; Tardio-Baiges, Antoni; Botana-Rial, Maribel; Núñez-Delgado, Manuel; Álvarez-Martín, M Jesús; Fernández-Villar, Alberto
2014-07-01
Cell block material from puncture can be obtained with endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) in many cases. The aim of this study was to analyse the value of additional information from cell blocks obtained with EBUS-TBNA samples from mediastinal and hilar lymph nodes and masses. Review of pathology reports with a specific diagnosis obtained from EBUS-TBNA samples of mediastinal or hilar lesions, prospectively obtained over a two-year period. The generation of cell blocks from cytology needle samples, the contribution to morphological diagnosis, and the possible use of samples for immunohistochemistry were analysed. One hundred and twenty-nine samples corresponding to 110 patients were reviewed. The diagnosis was lung cancer in 81% of cases, extrapulmonary carcinoma in 10%, sarcoidosis in 4%, lymphoma in 2.7%, and tuberculosis in 0.9%. Cell blocks could be obtained in 72% of cases. Immunohistochemistry studies on the cell blocks were significantly easier to perform than on conventional smears (52.6% vs. 14%, P<.0001). In 4cases, the cell block provided an exclusive morphological diagnosis (3sarcoidosis and one metastasis from prostatic carcinoma) and in 3carcinomas, subtype and origin could be identified. Exclusive diagnoses from the cell block were significantly more frequent in benign disease than in malignant disease (25% vs 0.9%, P=.002). Cell blocks were obtained from 72% of EBUS-TBNA diagnostic procedures. The main contributions of cell blocks to pathology examinations were the possibility of carrying out immunohistochemical staining for the better classification of neoplasms, especially extrapulmonary metastatic tumours, and the improved diagnosis of benign lesions. Copyright © 2013 SEPAR. Published by Elsevier Espana. All rights reserved.
Mahan, Angel F; McEvoy, Matthew D; Gravenstein, Nikolaus
2016-04-01
In modern practice, real-time ultrasound guidance is commonly employed for the placement of internal jugular vein catheters. With a new tool, such as ultrasound, comes the opportunity to refine and further optimize the ultrasound view during jugular vein catheterization. We describe jugular vein access techniques and use the long-axis view as an alternative to the commonly employed short-axis cross-section view for internal jugular vein access and cannulation. The long-axis ultrasound-guided internal jugular vein approach for internal jugular vein cannulation is a useful alternative technique that can provide better needle tip and guidewire visualization than the more traditional short-axis ultrasound view.
Bonmati, Ester; Hu, Yipeng; Villarini, Barbara; Rodell, Rachael; Martin, Paul; Han, Lianghao; Donaldson, Ian; Ahmed, Hashim U; Moore, Caroline M; Emberton, Mark; Barratt, Dean C
2018-04-01
Image-guided systems that fuse magnetic resonance imaging (MRI) with three-dimensional (3D) ultrasound (US) images for performing targeted prostate needle biopsy and minimally invasive treatments for prostate cancer are of increasing clinical interest. To date, a wide range of different accuracy estimation procedures and error metrics have been reported, which makes comparing the performance of different systems difficult. A set of nine measures are presented to assess the accuracy of MRI-US image registration, needle positioning, needle guidance, and overall system error, with the aim of providing a methodology for estimating the accuracy of instrument placement using a MR/US-guided transperineal approach. Using the SmartTarget fusion system, an MRI-US image alignment error was determined to be 2.0 ± 1.0 mm (mean ± SD), and an overall system instrument targeting error of 3.0 ± 1.2 mm. Three needle deployments for each target phantom lesion was found to result in a 100% lesion hit rate and a median predicted cancer core length of 5.2 mm. The application of a comprehensive, unbiased validation assessment for MR/US guided systems can provide useful information on system performance for quality assurance and system comparison. Furthermore, such an analysis can be helpful in identifying relationships between these errors, providing insight into the technical behavior of these systems. © 2018 American Association of Physicists in Medicine.
Fluoroscopic image-guided intervention system for transbronchial localization
NASA Astrophysics Data System (ADS)
Rai, Lav; Keast, Thomas M.; Wibowo, Henky; Yu, Kun-Chang; Draper, Jeffrey W.; Gibbs, Jason D.
2012-02-01
Reliable transbronchial access of peripheral lung lesions is desirable for the diagnosis and potential treatment of lung cancer. This procedure can be difficult, however, because accessory devices (e.g., needle or forceps) cannot be reliably localized while deployed. We present a fluoroscopic image-guided intervention (IGI) system for tracking such bronchoscopic accessories. Fluoroscopy, an imaging technology currently utilized by many bronchoscopists, has a fundamental shortcoming - many lung lesions are invisible in its images. Our IGI system aligns a digitally reconstructed radiograph (DRR) defined from a pre-operative computed tomography (CT) scan with live fluoroscopic images. Radiopaque accessory devices are readily apparent in fluoroscopic video, while lesions lacking a fluoroscopic signature but identifiable in the CT scan are superimposed in the scene. The IGI system processing steps consist of: (1) calibrating the fluoroscopic imaging system; (2) registering the CT anatomy with its depiction in the fluoroscopic scene; (3) optical tracking to continually update the DRR and target positions as the fluoroscope is moved about the patient. The end result is a continuous correlation of the DRR and projected targets with the anatomy depicted in the live fluoroscopic video feed. Because both targets and bronchoscopic devices are readily apparent in arbitrary fluoroscopic orientations, multiplane guidance is straightforward. The system tracks in real-time with no computational lag. We have measured a mean projected tracking accuracy of 1.0 mm in a phantom and present results from an in vivo animal study.
Modeling, Production, and Testing of an Echogenic Needle for Ultrasound-Guided Nerve Blocks.
Bigeleisen, Paul E; Hess, Aaron; Zhu, Richard; Krediet, Annelot
2016-06-01
We have designed, produced, and tested an echogenic needle based on a sawtooth pattern where the height of the tooth was 1.25 times the wavelength of the ultrasound transducer. A numeric solution to the time-independent wave equation (Helmholtz equation) was used to create a model of backscattering from a needle. A 21-gauge stainless steel prototype was manufactured and tested in a water bath. Backscattering from the needle was compared to theoretical predications from our model. Based on these results, an 18-gauge prototype needle was fabricated from stainless steel and tested in a pig cadaver. This needle was compared to a commercial 18-gauge echogenic needle (Pajunk Medical Systems, Tucker, GA) by measuring the brightness of the needle relative to the background of sonograms of a needle in a pig cadaver. The backscattering from the 21-gauge prototype needle reproduced the qualitative predictions of our model. At 30° and 45° of insonation, our prototype performed equivalently to the Pajunk needle. At 60°, our prototype was significantly brighter than the Pajunk needle (P = .017). In conclusion, we chose a model for the design of an echogenic needle and modeled it on the basis of a solution to the Helmholtz equation. A prototype needle was tested in a water bath and compared to the model prediction. After verification of our model, we designed an 18-gauge needle, which performed better than an existing echogenic needle (Pajunk) at 60° of insonation. Our needle will require further testing in human trials. © 2016 by the American Institute of Ultrasound in Medicine.
Ultrasound-guided interventional procedures around the shoulder.
Messina, Carmelo; Banfi, Giuseppe; Orlandi, Davide; Lacelli, Francesca; Serafini, Giovanni; Mauri, Giovanni; Secchi, Francesco; Silvestri, Enzo; Sconfienza, Luca Maria
2016-01-01
Ultrasound is an established modality for shoulder evaluation, being accurate, low cost and radiation free. Different pathological conditions can be diagnosed using ultrasound and can be treated using ultrasound guidance, such as degenerative, traumatic or inflammatory diseases. Subacromial-subdeltoid bursitis is the most common finding on ultrasound evaluation for painful shoulder. Therapeutic injections of corticosteroids are helpful to reduce inflammation and pain. Calcific tendinopathy of rotator cuff affects up to 20% of painful shoulders. Ultrasound-guided treatment may be performed with both single- and double-needle approach. Calcific enthesopathy, a peculiar form of degenerative tendinopathy, is a common and mostly asymptomatic ultrasound finding; dry needling has been proposed in symptomatic patients. An alternative is represented by autologous platelet-rich plasma injections. Intra-articular injections of the shoulder can be performed in the treatment of a variety of inflammatory and degenerative diseases with corticosteroids or hyaluronic acid respectively. Steroid injections around the long head of the biceps brachii tendon are indicated in patients with biceps tendinopathy, reducing pain and humeral tenderness. The most common indication for acromion-clavicular joint injection is degenerative osteoarthritis, with ultrasound representing a useful tool in localizing the joint space and properly injecting various types of drugs (steroids, lidocaine or hyaluronic acid). Suprascapular nerve block is an approved treatment for chronic shoulder pain non-responsive to conventional treatments as well as candidate patients for shoulder arthroscopy. This review provides an overview of these different ultrasonography-guided procedures that can be performed around the shoulder.
... the thyroid and see if the nodule is solid or filled with fluid (cystic). Although this test cannot tell if the nodule is cancerous, it is very useful to guide the needle to remove (aspirate) cells from nodules. This procedure is called “ultrasound-guided ...
Treatment of supraspinatus tendinopathy with ultrasound guided dry needling.
Settergren, Roy
2013-03-01
The purpose of this case study is to describe the treatment of a patient with tendinopathy using sonographically guided dry needling. Tendinopathies are a highly prevalent problem in musculoskeletal medicine, and no one form of treatment has gained universal acceptance as being superior to another. A 30-year-old woman with a 4-month history of anterolateral right shoulder pain was diagnosed with supraspinatus tendinopathy upon physical examination, which was confirmed with diagnostic sonography. Sonography was used to guide an acupuncture needle into the pathologic tissue to induce a humoral healing response. Therapeutic exercise was also prescribed. At 10-day follow-up, increased echogenicity was found in the previously heterogenous hypoechoic areas. The patient also experienced a subjective resolution of her shoulder pain, which did not return with increased physical activity. Sonographically guided dry needling was shown to be beneficial for this patient as evident by sonographic changes pre- and postprocedure.
Hopps, Carin V; Goldstein, Marc
2002-09-01
We describe a technique by which incidental, nonpalpable intratesticular tumors are excised using intraoperative ultrasonography and the operating microscope. Men with impalpable intratesticular tumors incidentally detected by ultrasonography underwent intraoperative ultrasound guided needle localization and microsurgical exploration of the mass. The testis was delivered through an inguinal incision and placed on ice to minimize warm ischemia. Two rubber shod vascular clamps were placed across the spermatic cord. The tumor was identified by ultrasound and localized with a 30 gauge needle, which was placed adjacent to the tumor. An operating microscope providing 6x to 25x magnification was used to excise the lesion with a 2 to 5 mm. margin. Tissue diagnosis was obtained by frozen section. Multiple random biopsies of the remaining parenchyma were done to confirm absent malignancy. Ultrasound showed incidental, nonpalpable testis tumors in 4 of the 65 men who underwent infertility evaluation and were entered into the microsurgical testis biopsy database between January 1995 and December 2001. All lesions were hypoechoic. Frozen section analysis of the lesions revealed 2 Leydig cell tumors, 1 mass with an inconclusive pathological diagnosis and 1 inflammatory mass. On permanent section the latter 2 lesions were seminoma. The seminomas were 1.6 and 0.9 cm. in the greatest diameter, and the Leydig cell tumors were 0.35 and 0.2 cm., respectively. Random biopsies were positive for seminoma and intratubular germ cell neoplasia in both testes with seminoma. These 2 patients subsequently opted to undergo radical orchiectomy. No residual tumor was detected in either radical orchiectomy specimen. Intraoperative ultrasound guided needle localization with microsurgical exploration is a safe and effective approach to even small impalpable testicular masses. This technique provides the opportunity to identify and remove benign and malignant lesions, and preserve the testis when the lesion is benign. In cases of a solitary testis or bilateral synchronous lesions the technique allows a potentially testis sparing operation for small malignancies.
NASA Astrophysics Data System (ADS)
Beigi, Parmida; Rohling, Robert
2014-03-01
Despite the wide range and long history of ultrasound guided needle insertions, an unresolved issue in many cases is clear needle visibility. A well-known ad hoc technique to detect the needle is to move the stylet and look for changes in the needle appearance. We present a new method to automatically locate a moving stylet/catheter within a stationary cannula using motion detection. We then use this information to detect the needle trajectory and the tip. The differences between the current frame and the previous frame are detected and localized, to minimize the influence of tissue global motions. A polynomial fit based on the detected needle axis determines the estimated stylet shaft trajectory, and the extent of the differences along the needle axis represents the tip. Over a few periodic movements of the stylet including its full insertion into the cannula to the tip, a combination of polynomial fits determines the needle trajectory and the last detected point represents the needle tip. Experiments are conducted in water bath and bovine muscle tissue for several stylet/catheter materials. Results show that a plastic stylet has the best needle shaft and tip localization accuracy in the water bath with RMSE = 0:16 mm and RMSE = 0:51 mm, respectively. In the bovine tissue, the needle tip was best localized with the plastic catheter with RMSE = 0:33 mm. The stylet tip localization was most accurate with the steel stylet, with RMSE = 2:81 mm and the shaft was best localized with the plastic catheter, with RMSE = 0:32 mm.
A Man with Pancreatic Head Mass Lesion on Endoscopic Ultrasound and Granuloma on Cytopathology.
Rad, Neda; Heidarnezhad, Arash; Soheili, Setareh; Mohammad-Alizadeh, Amir Houshang; Nikmanesh, Arash
2016-01-01
Primary pancreatic lymphoma is an unlikely malignancy accounting for less than 0.5% of pancreatic tumors. Clinical presentation is often nonspecific and may be clinically misdiagnosed as pancreatic adenocarcinoma. Here we present an Iranian case of primary pancreatic lymphoma in a 47-year-old male suffering from jaundice and 20% weight loss. Endoscopic ultrasound revealed a mixed echoic mass lesion at the head of pancreas. The patient underwent endoscopic ultrasound-guided fine needle aspiration of solid pancreatic mass and histopathologic diagnosis revealed granuloma. Computed tomography-guided core needle biopsy was performed and eventually histological examination showed granuloma that was coherent with the diagnosis of primary pancreatic lymphoma. Primary pancreatic lymphoma is a rare entity presenting with nonspecific symptoms, laboratory and radiological findings. Computed tomography results in combination with clinical and radiological studies generally provide guidance for appropriate investigation.
A Man with Pancreatic Head Mass Lesion on Endoscopic Ultrasound and Granuloma on Cytopathology
Rad, Neda; Heidarnezhad, Arash; Soheili, Setareh; Mohammad-Alizadeh, Amir Houshang; Nikmanesh, Arash
2016-01-01
Primary pancreatic lymphoma is an unlikely malignancy accounting for less than 0.5% of pancreatic tumors. Clinical presentation is often nonspecific and may be clinically misdiagnosed as pancreatic adenocarcinoma. Here we present an Iranian case of primary pancreatic lymphoma in a 47-year-old male suffering from jaundice and 20% weight loss. Endoscopic ultrasound revealed a mixed echoic mass lesion at the head of pancreas. The patient underwent endoscopic ultrasound-guided fine needle aspiration of solid pancreatic mass and histopathologic diagnosis revealed granuloma. Computed tomography-guided core needle biopsy was performed and eventually histological examination showed granuloma that was coherent with the diagnosis of primary pancreatic lymphoma. Primary pancreatic lymphoma is a rare entity presenting with nonspecific symptoms, laboratory and radiological findings. Computed tomography results in combination with clinical and radiological studies generally provide guidance for appropriate investigation. PMID:28100998
Accuracy and safety of ultrasound-guided percutaneous needle core biopsy of renal masses
Wang, Xianding; Lv, Yuanhang; Xu, Zilin; Aniu, Muguo; Qiu, Yang; Wei, Bing; Li, Xiaohong; Wei, Qiang; Dong, Qiang; Lin, Tao
2018-01-01
Abstract Our aim is to determine the sufficiency, accuracy, and safety of ultrasound-guided percutaneous needle core biopsy of renal masses in Chinese patients. Patients who had undergone ultrasound-guided needle core renal mass biopsy from June 2012 to June 2016 at West China Hospital, China were retrospectively reviewed. The information obtained included demographics, mass-related parameters, biopsy indications, technique, complications, pathologic results, and follow-up. Concordance of surgical resection pathology and follow-up data were assessed. Renal mass biopsies were performed in 106 patients. Thirty-nine (36.8%) were asymptomatic. The male/female ratio was 60/46, with a median age of 49.5 years. Median mass size was 8.1 cm (range 1.8–20). Biopsy was performed through a 16-gauge needle, with median cores of 2 taken (range 1–5). Only one significant biopsy-related complication (hemorrhage requiring transfusion) was encountered. An adequate tissue sample was obtained in 97.2% (103/106) of biopsies. Eighty-seven biopsies (82.1%) showed malignant neoplasms, 16 (15.1%) yielded benignity, and 3 (2.8%) were nondiagnostic. After biopsy, 46 patients (43.4%) underwent surgery. Compared with the subsequent mass resection pathology, the biopsy diagnoses were identical in 43 cases. The accuracy rate of biopsy distinguishing malignant from benign lesions was 99.1%, and the rate for determining tumor histological type (excluding the nondiagnostic biopsies) was 95.1%. The sensitivity and specificity in detecting malignancy were 98.9% and 100%, respectively. In several situations, there is still a role for biopsy before intervention. Percutaneous needle core biopsy under ultrasonography guidance is highly accurate and safe, and can determine the proper management of undefinable masses. PMID:29595650
Paul-Murphy, J; O'Brien, R T; Spaeth, A; Sullivan, L; Dubielzig, R R
1999-01-01
The large mesenteric lymph node of 28 normal ferrets was imaged with ultrasound. The large node, located in the mid-abdomen at the root of the mesentery, was round to ovoid and uniformly hyperechoic. Mean ultrasonographic dimensions of the lymph node were 12.6 +/- 2.6 mm by 7.6 +/- 2.0 mm. Fine needle aspirates of 20 lymph nodes were obtained either using ultrasound guided free-hand techniques or at necropsy. The cytological descriptions were compared to histological descriptions of 13 lymph node core biopsies obtained during laparotomy or necropsy as well as 10 peripheral blood smear differentials. The large mesenteric lymph node of ferrets could be easily imaged and measured by ultrasound and evaluated by fine needle aspirate cytology. Normal lymph node cytology may include an eosinophilic infiltrate.
García Bermejo, Paula; De La Cruz Torres, Blanca; Naranjo Orellana, José; Albornoz Cabello, Manuel
2018-01-01
The aim of this study was to establish if the changes in sympathetic and parasympathetic activity (analyzed through heart-rate variability [HRV]) during ultrasound (US)-guided percutaneous needle electrolysis (PNE) is due to the effect of needle puncture only or of the PNE technique per se where the puncture and galvanic current are combined. This was an experimental, case-control study that took place at the University of Seville. Subjects were 36 male footballers who were randomly allocated to three groups: a control group (CG; 12 players), for whom HRV was recorded for 10 min, both at rest and during an exhaustive US examination of the patellar tendon and adjacent structures; a first experimental group (PNE group; 12 players), for whom HRV was recorded for 10 min, both at rest and during application of US-guided PNE in the patellar tendon; and a second experimental group (needle group; 12 players), for whom HRV was recorded for 10 min, both at rest and during application of US-guided PNE without electrical current in the patellar tendon. The outcome measures were the diameters of the Poincaré plot (SD1, SD2), stress score, and sympathetic/parasympathetic ratio. There were no differences between groups in any baseline measurements, nor were there any significant differences between CG measurements (baseline vs. intervention). The PNE group exhibited statistically significant increases in SD1 (p = 0.01) and SD2 (p = 0.004) and statistically significant decreases in SS and S/PS ratio (p = 0.03), indicating increased parasympathetic and decreased sympathetic activity, respectively. The needle group exhibited statistically significant increases in SD2 (p = 0.02) and statistically significant decreases in SS (p = 0.02), indicating decreased sympathetic activity. The application of the US-guided PNE technique caused a measurable increase in parasympathetic activity (detected by HRV), which was due to the combination of needle puncture and electric current.
Baez, E; Huber, A; Vetter, M; Hackelöer, B-J
2003-03-01
The aim of this study was to evaluate the use of three-dimensional (3D) ultrasonography in the complete excision of benign breast tumors using ultrasound-guided vacuum-assisted core-needle biopsy (Mammotome). A protocol for the management of benign breast tumors is proposed. Twenty consecutive patients with sonographically benign breast lesions underwent 3D ultrasound-guided mammotome biopsy under local anesthesia. The indication for surgical biopsy was a solid lesion with benign characteristics on both two-dimensional (2D) and 3D ultrasound imaging, increasing in size over time or causing pain or irritation. Preoperatively, the size of the lesion was assessed using 2D and 3D volumetry. During vacuum biopsy the needle was visualized sonographically in all three dimensions, including the coronal plane. Excisional biopsy was considered complete when no residual tumor tissue could be seen sonographically. Ultrasonographic follow-up examinations were performed on the following day and 3-6 months later to assess residual tissue and scarring. All lesions were histologically benign. Follow-up examinations revealed complete excision of all lesions of < 1.5 mL in volume as assessed by 3D volumetry. 3D ultrasonographic volume assessment was more accurate than 2D using the ellipsoid formula or assessment of the maximum diameter for the prediction of complete excision of the tumor. No bleeding or infections occurred postoperatively and no scarring was seen ultrasonographically on follow-up examinations. Ultrasound-guided vacuum-assisted biopsy allows complete excision of benign breast lesions that are =1.5 mL in volume (calculated by 3D volumetry), and thus avoids open surgery and postoperative scarring. Under local anesthesia it is a safe procedure with optimal compliance. 3D ultrasound offers the advantage of better preoperative demonstration of the lesions' margins, resulting in better assessment of volumetry, improved intraoperative needle location and perioperative identification of residual tumor tissue. 3D sonographically guided biopsy should be integrated into breast cancer screening programs as a safe therapeutic option for breast lesions presumed to be benign. Copyright 2003 ISUOG. Published by John Wiley & Sons, Ltd.
A novel platform for electromagnetic navigated ultrasound bronchoscopy (EBUS).
Sorger, Hanne; Hofstad, Erlend Fagertun; Amundsen, Tore; Langø, Thomas; Leira, Håkon Olav
2016-08-01
Endobronchial ultrasound transbronchial needle aspiration (EBUS-TBNA) of mediastinal lymph nodes is essential for lung cancer staging and distinction between curative and palliative treatment. Precise sampling is crucial. Navigation and multimodal imaging may improve the efficiency of EBUS-TBNA. We demonstrate a novel EBUS-TBNA navigation system in a dedicated airway phantom. Using a convex probe EBUS bronchoscope (CP-EBUS) with an integrated sensor for electromagnetic (EM) position tracking, we performed navigated CP-EBUS in a phantom. Preoperative computed tomography (CT) and real-time ultrasound (US) images were integrated into a navigation platform for EM navigated bronchoscopy. The coordinates of targets in CT and US volumes were registered in the navigation system, and the position deviation was calculated. The system visualized all tumor models and displayed their fused CT and US images in correct positions in the navigation system. Navigating the EBUS bronchoscope was fast and easy. Mean error observed between US and CT positions for 11 target lesions (37 measurements) was [Formula: see text] mm, maximum error was 5.9 mm. The feasibility of our novel navigated CP-EBUS system was successfully demonstrated. An EBUS navigation system is needed to meet future requirements of precise mediastinal lymph node mapping, and provides new opportunities for procedure documentation in EBUS-TBNA.
Kavrut Ozturk, Nilgun; Kavakli, Ali Sait
2017-08-01
This prospective randomized study compared the coracoid and retroclavicular approaches to ultrasound-guided infraclavicular brachial plexus block (IBPB) in terms of needle tip and shaft visibility and quality of block. We hypothesized that the retroclavicular approach would increase needle tip and shaft visibility and decrease the number of needle passes compared to the coracoid approach. A total of 100 adult patients who received IBPB block for upper limb surgery were randomized into two groups: a coracoid approach group (group C) and a retroclavicular approach group (group R). In group C, the needle was inserted 2 cm medial and 2 cm inferior to the coracoid process and directed from ventral to dorsal. In group R, the needle insertion point was posterior to the clavicle and the needle was advanced from cephalad to caudal. All ultrasound images were digitally stored for analysis. The primary aim of the present study was to compare needle tip and shaft visibility between the coracoid approach and retroclavicular approach in patients undergoing upper limb surgery. The secondary aim was to investigate differences between the two groups in the number of needle passes, sensory and motor block success rates, surgical success rate, block performance time, block performance-related pain, patient satisfaction, use of supplemental local anesthetic and analgesic, and complications. Needle tip visibility and needle shaft visibility were significantly better in group R (p = 0.040, p = 0.032, respectively). Block performance time and anesthesia-related time were significantly shorter in group R (p = 0.022, p = 0.038, respectively). Number of needle passes was significantly lower in group R (p = 0.044). Paresthesia during block performance was significantly higher in group C (p = 0.045). There were no statistically significant differences between the two groups in terms of sensory or motor block success, surgical success, block-related pain, and patient satisfaction. The retroclavicular approach is associated with better needle tip and shaft visibility, reduced performance time and anesthesia-related time, less paresthesia during block performance, and fewer needle passes than the coracoid approach. TRıAL REGISTRY NUMBER: Clinicaltrials.gov (no. NCT02673086).
Ballegeer, Elizabeth A; Forrest, Lisa J; Dickinson, Ryan M; Schutten, Melissa M; Delaney, Fern A; Young, Karen M
2007-03-01
To determine the accuracy of cytologic diagnosis, compared with histologic diagnosis, in determination of disease in ultrasound-guided fine-needle aspirates of splenic lesions. Retrospective study. Splenic specimens from 29 dogs and 3 cats. Records were searched for dogs and cats that had undergone ultrasound-guided splenic aspiration. Criteria for inclusion were ultrasonographic identification of splenic lesions and cytologic and histologic evaluation of tissue from the same lesion. Cytologic samples were obtained by fine-needle aspiration, and histologic specimens were obtained via surgical biopsy, ultrasound-guided biopsy, or necropsy. Cytologic diagnoses corresponded with histologic diagnoses in 19 of 31 (61.3%) cases and differed in 5 of 31(16.1%) cases, and 1 aspirate was inadequate for evaluation. In 7 of 31 (22.6%) cases, histologic evaluation of tissue architecture was required to distinguish between reactive and neoplastic conditions. On the basis of histologic diagnosis in 14 animals with nonneoplastic conditions, the cytologic diagnosis was correct in 11 cases, not definitive in 2 cases, and incorrect in 1 case. In 17 animals with malignant neoplastic diseases, the cytologic diagnosis was correct in 8 cases, not definitive but consistent with possible neoplasia in 5 cases, and incorrect in 4 cases. Multiple similar-appearing nodules were significantly associated with malignancy, whereas single lesions were more often benign. Ultrasound-guided aspiration of splenic lesions is a minimally invasive tool for obtaining specimens for cytologic evaluation. Although cytologic diagnoses often reflect histologic results, if missampling or incomplete sampling occurs or tissue architecture is required to distinguish between reactive and neoplastic conditions, accurate diagnosis with fine-needle aspiration may not be possible.
Ultrasound-guided peripheral nerve interventions for common pain disorders
Krishna Prasad, B P; Joy, Binu; Raghavendra, Vijayakumar A; Toms, Ajith; George, Danny; Ray, Brijesh
2018-01-01
There are a number of common pain disorders that can be managed effectively by injections around or ablation of peripheral nerves. Ultrasound is a universally available imaging tool, is safe, cost-effective, and is excellent in imaging many peripheral nerves and guiding needles to the site of the nerves. This article aims to present an overview of indications and techniques of such procedures that can be effectively performed by a radiologist. PMID:29692534
Oh, Hyoung-Chul; Kang, Hyun; Lee, Jae Young; Choi, Geun Joo; Choi, Jung Sik
2016-11-01
To compare the diagnostic accuracy of endoscopic ultrasound-guided core needle aspiration with that of standard fine-needle aspiration by systematic review and meta-analysis. Studies using 22/25-gauge core needles, irrespective of comparison with standard fine needles, were comprehensively reviewed. Pooled sensitivity, specificity, diagnostic odds ratio (DOR), and summary receiver operating characteristic curves for the diagnosis of malignancy were used to estimate the overall diagnostic efficiency. The pooled sensitivity, specificity, and DOR of the core needle for the diagnosis of malignancy were 0.88 (95% confidence interval [CI], 0.84 to 0.90), 0.99 (95% CI, 0.96 to 1), and 167.37 (95% CI, 65.77 to 425.91), respectively. The pooled sensitivity, specificity, and DOR of the standard needle were 0.84 (95% CI, 0.79 to 0.88), 1 (95% CI, 0.97 to 1), and 130.14 (95% CI, 34.00 to 495.35), respectively. The area under the curve of core and standard needle in the diagnosis of malignancy was 0.974 and 0.955, respectively. The core and standard needle were comparable in terms of pancreatic malignancy diagnosis. There was no significant difference in procurement of optimal histologic cores between core and standard needles (risk ratio [RR], 0.545; 95% CI, 0.187 to 1.589). The number of needle passes for diagnosis was significantly lower with the core needle (standardized mean difference, -0.72; 95% CI, -1.02 to -0.41). There were no significant differences in overall complications (RR, 1.26; 95% CI, 0.34 to 4.62) and technical failure (RR, 5.07; 95% CI, 0.68 to 37.64). Core and standard needles were comparable in terms of diagnostic accuracy, technical performance, and safety profile.
Ultrasound-guided rectus sheath block in children with umbilical hernia: Case series.
Alsaeed, Abdul Hamid; Thallaj, Ahmed; Khalil, Nancy; Almutaq, Nada; Aljazaeri, Ayman
2013-10-01
Umbilical hernia repair, a common day-case surgery procedure in children, is associated with a significant postoperative pain. The most popular peripheral nerve blocks used in umbilical hernia repair are rectus sheath infiltration and caudal block. The rectus sheath block may offer improved pain relief following umbilical hernia repair with no undesired effects such as lower limb motor weakness or urinary retention seen with caudal block which might delay discharge from the hospital. Ultrasound guidance of peripheral nerve blocks has reduced the number of complications and improved the quality of blocks. The aim of this case series is to assess the post rectus sheath block pain relief in pediatric patients coming for umbilical surgery. Twenty two (22) children (age range: 1.5-8 years) scheduled for umbilical hernia repair were included in the study. Following the induction of general anesthesia, the ultrasonographic anatomy of the umbilical region was studied with a 5-16 MHz 50 mm linear probe. An ultrasound-guided posterior rectus sheath block of both rectus abdominis muscles (RMs) was performed (total of 44 punctures). An in-plain technique using Stimuplex A insulated facet tip needle 22G 50mm. Surgical conditions, intraoperative hemodynamic parameters, and postoperative analgesia by means of the modified CHEOPS scale were evaluated. ultrasonograghic visualization of the posterior sheath was possible in all patients. The ultrasound guided rectus sheath blockade provided sufficient analgesia in all children with no need for additional analgesia except for one patient who postoperatively required morphine 0.1 mg/kg intravenously. There were no complications. Ultrasound guidance enables performances of an effective rectus sheath block for umbilical hernia. Use of the Stimuplex A insulated facet tip needle 22G 50mm provides easy, less traumatic skin and rectus muscle penetration and satisfactory needle visualiza.
Transjugular intrahepatic portosystemic shunt creation using intravascular ultrasound guidance.
Farsad, Khashayar; Fuss, Cristina; Kolbeck, Kenneth J; Barton, Robert E; Lakin, Paul C; Keller, Frederick S; Kaufman, John A
2012-12-01
To describe the use of intravascular ultrasound (US) guidance for creation of transjugular intrahepatic portosystemic shunts (TIPSs) in humans. The initial 25 cases of intravascular US-guided TIPS were retrospectively compared versus the last 75 conventional TIPS cases during the same time period at the same institution in terms of the number of needle passes required to establish portal vein (PV) access, fluoroscopy time, and needle pass-related complications. Intravascular US-guided TIPS creation was successful in all cases, and there was no statistically significant difference in number of needle passes, fluoroscopy time, or needle pass-related complications between TIPS techniques. Intravascular US-guided TIPS creation was successful in cases in which conventional TIPS creation had failed as a result of PV thrombosis or distorted anatomy. Intravascular US guidance for TIPS creation was additionally useful in a patient with Budd-Chiari syndrome and in a patient with intrahepatic tumors. Intravascular US is a safe and reproducible means of real-time image guidance for TIPS creation, equivalent in efficacy to conventional fluoroscopic guidance. Real-time sonographic guidance with intravascular US may prove advantageous for cases in which there is PV thrombus, distorted anatomy, Budd-Chiari syndrome, or hepatic tumors. Copyright © 2012 SIR. Published by Elsevier Inc. All rights reserved.
Ultrasound-guided core needle biopsy of cervical lymph nodes in the diagnosis of toxoplasmosis.
Cho, Woojin; Kim, Min Kyung; Sim, Jung Suk
2017-05-01
Our study investigates whether the histopathological features of toxoplasmic lymphadenitis (TL), specifically noncaseating microgranuloma and follicular hyperplasia, can be obtained by sonographic-guided core needle biopsy (CNB) of cervical lymph nodes. Thirty-two patients seen from June 2014 to March 2015 were positive for toxoplasma immunoglobulin M antibody. Among those patients, 21 underwent CNB of a cervical lymph node and were enrolled in this study. The pathologic findings were reviewed. Twenty-nine lymph nodes in 21 patients were sampled. Eighteen of the 21 (86%) patients had a microgranuloma without caseating necrosis or giant cells, and all 21 (100%) patients had follicular hyperplasia. The histologic findings of TL were detected by sonographic-guided CNB, which can be used as part of the first line of investigation in patients with unexplained cervical adenopathy. © 2016 Wiley Periodicals, Inc. J Clin Ultrasound 45:192-196, 2017. © 2016 Wiley Periodicals, Inc.
Klauser, Andrea; De Zordo, Tobias; Feuchtner, Gudrun; Sögner, Peter; Schirmer, Michael; Gruber, Johann; Sepp, Norbert; Moriggl, Bernhard
2008-11-15
Sacroiliitis is often caused by rheumatic diseases, and besides other therapeutic options, treatment consists of intraarticular injection of corticosteroids. The purpose of this study was to assess the feasibility of ultrasound (US)-guided sacroiliac joint (SI joint) injection at 2 different puncture levels in cadavers and patients when defined sonoanatomic landmarks were considered. After defining sonoanatomic landmarks, US-guided needle insertion was performed in 10 human cadavers (20 SI joints) at 2 different puncture sites. Upper level was defined at the level of the posterior sacral foramen 1 and lower level at the level of the posterior sacral foramen 2. In 10 patients with unilateral sacroiliitis, injection at the most feasible level was attempted. Computed tomography confirmed correct intraarticular needle placement in cadavers by showing the tip of the needle in the joint and intraarticular diffusion of contrast media in 16 (80%) of 20 SI joints (upper level 7 [70%] of 10; lower level 9 [90%] of 10). In all 4 cases in which needle insertion failed, intraarticular SI joint injection at the other level was successful. In patients, 100% of US-guided injections were successful (8 lower level, 2 upper level), with a mean pain relief of 8.6 after 3 months. US guidance of needle insertion into SI joints was feasible at both levels when defined sonoanatomic landmarks were used. If SI joint alterations do not allow for direct visualization of the dorsal joint space of the lower level, which is easier to access, the upper level might offer an appropriate alternative.
Tsuchiya, Masahiko; Mizutani, Koh; Funai, Yusuke; Nakamoto, Tatsuo
2016-02-01
Ultrasound-guided procedures may be easier to perform when the operator's eye axis, needle puncture site, and ultrasound image display form a straight line in the puncture direction. However, such methods have not been well tested in clinical settings because that arrangement is often impossible due to limited space in the operating room. We developed a wireless remote display system for ultrasound devices using a tablet computer (iPad Mini), which allows easy display of images at nearly any location chosen by the operator. We hypothesized that the in-line layout of ultrasound images provided by this system would allow for secure and quick catheterization of the radial artery. We enrolled first-year medical interns (n = 20) who had no prior experience with ultrasound-guided radial artery catheterization to perform that using a short-axis out-of-plane approach with two different methods. With the conventional method, only the ultrasound machine placed at the side of the head of the patient across the targeted forearm was utilized. With the tablet method, the ultrasound images were displayed on an iPad Mini positioned on the arm in alignment with the operator's eye axis and needle puncture direction. The success rate and time required for catheterization were compared between the two methods. Success rate was significantly higher (100 vs. 70 %, P = 0.02) and catheterization time significantly shorter (28.5 ± 7.5 vs. 68.2 ± 14.3 s, P < 0.001) with the tablet method as compared to the conventional method. An ergonomic straight arrangement of the image display is crucial for successful and quick completion of ultrasound-guided arterial catheterization. The present remote display system is a practical method for providing such an arrangement.
Vanderhoek, Matthew David; Hoang, Hieu T; Goff, Brandon
2013-09-01
Occipital neuralgia is a condition manifested by chronic occipital headaches and is thought to be caused by irritation or trauma to the greater occipital nerve (GON). Treatment for occipital neuralgia includes medications, nerve blocks, and pulsed radiofrequency ablation (PRFA). Landmark-guided GON blocks are the mainstay in both the diagnosis and treatment of occipital neuralgia. Ultrasound is being utilized more and more in the chronic pain clinic to guide needle advancement when performing procedures; however, there are no reports of ultrasound used to guide a diagnostic block or PRFA of the GON. We report two cases in which ultrasound was used to guide diagnostic greater occipital nerve blocks and greater occipital nerve pulsed radiofrequency ablation for treatment of occipital neuralgia. Two patients with occipital headaches are presented. In Case 1, ultrasound was used to guide diagnostic blocks of the greater occipital nerves. In Case 2, ultrasound was utilized to guide placement of radiofrequency probes for pulsed radiofrequency ablation of the greater occipital nerves. Both patients reported immediate, significant pain relief, with continued pain relief for several months. Further study is needed to examine any difference in outcomes or morbidity between the traditional landmark method versus ultrasound-guided blocks and pulsed radiofrequency ablation of the greater occipital nerves.
VanderHoek, Matthew David; Hoang, Hieu T; Goff, Brandon
2013-01-01
Occipital neuralgia is a condition manifested by chronic occipital headaches and is thought to be caused by irritation or trauma to the greater occipital nerve (GON). Treatment for occipital neuralgia includes medications, nerve blocks, and pulsed radiofrequency ablation (PRFA). Landmark-guided GON blocks are the mainstay in both the diagnosis and treatment of occipital neuralgia. Ultrasound is being utilized more and more in the chronic pain clinic to guide needle advancement when performing procedures; however, there are no reports of ultrasound used to guide a diagnostic block or PRFA of the GON. We report two cases in which ultrasound was used to guide diagnostic greater occipital nerve blocks and greater occipital nerve pulsed radiofrequency ablation for treatment of occipital neuralgia. Two patients with occipital headaches are presented. In Case 1, ultrasound was used to guide diagnostic blocks of the greater occipital nerves. In Case 2, ultrasound was utilized to guide placement of radiofrequency probes for pulsed radiofrequency ablation of the greater occipital nerves. Both patients reported immediate, significant pain relief, with continued pain relief for several months. Further study is needed to examine any difference in outcomes or morbidity between the traditional landmark method versus ultrasound-guided blocks and pulsed radiofrequency ablation of the greater occipital nerves. PMID:24282778
2017-08-14
Doctors Attending a Central Line Insertion Training Courses for New Residents of a University Hospital From March 2017 to June 2017; Physicians Who Had Less Than 10 Ultrasound Guided Internal Jugular Vein Cannulation Participate in This Study
A case of lung abscess successfully treated by transbronchial drainage using a guide sheath.
Izumi, Hiroki; Kodani, Masahiro; Matsumoto, Shingo; Kawasaki, Yuji; Igishi, Tadashi; Shimizu, Eiji
2017-05-01
A 51-year-old man was diagnosed with colon cancer in September 2011, and a solitary pulmonary nodule was detected by computed tomography (CT) scan. We performed a transbronchial biopsy with endobronchial ultrasonography using a guide sheath (GS) and diagnosed lung metastasis of colon cancer. The patient experienced remittent fever after the biopsy in spite of intravenous antibiotic therapies. Moreover, his CT scan showed a large lung abscess at the biopsy site. We performed transbronchial drainage using a GS as salvage therapy. The bloody pus was successfully aspirated, and chest X-ray following the procedure showed dramatic shrinkage of the abscess.
Siegenthaler, Andreas; Haug, Matthias; Eichenberger, Urs; Suter, Marc Rene; Moriggl, Bernhard
2013-05-01
Injection of opioids to the superior cervical ganglion (SCG) has been reported to provide pain relief in patients suffering from different kinds of neuropathic facial pain conditions, such as trigeminal neuralgia, postherpetic neuralgia, and atypical facial pain. The classic approach to the SCG is a transoral technique using a so-called "stopper" to prevent accidental carotid artery puncture. The main disadvantage of this technique is that the needle tip is positioned distant from the actual target, possibly impeding successful block of the SCG. A further limitation is that injection of local anesthetics due to potential carotid artery puncture is contraindicated. We hypothesized that the SCG can be identified and blocked using ultrasound imaging, potentially increasing precision of this technique. In this pilot study, 20 US-guided simulated blocks of the SCG were performed in 10 human cadavers in order to determine the accuracy of this novel block technique. After injection of 0.1 mL of dye, the cadavers were dissected to evaluate the needle position and coloring of the SCG. Nineteen of the 20 needle tips were located in or next to the SCG. This corresponded to a simulated block success rate of 95% (95% confidence interval 85-100%). In 17 cases, the SCG was completely colored, and in two cases, the caudal half of the SCG was colored with dye. The anatomical dissections confirmed that our ultrasound-guided approach to the SCG is accurate. Ultrasound could become an attractive alternative to the "blind" transoral technique of SCG blocks. Wiley Periodicals, Inc.
Kopac, Daniel S; Chen, Jerry; Tang, Raymond; Sawka, Andrew; Vaghadia, Himat
2013-09-01
Ultrasound-guided percutaneous vascular access for endovascular procedures is well established in surgical practice. Despite this, rates of complications from venous and arterial access procedures remain a significant cause of morbidity. We hypothesized that the use of a new technique of vascular access using an ultrasound with a novel needle-guidance positioning system (GPS) would lead to improved success rates of vascular puncture for both in-plane and out-of-plane techniques compared with traditional ultrasound. A prospective, randomized crossover study of medical students from all years of medical school was conducted using a phantom gel model. Each medical student performed three ultrasound-guided punctures with each of the four modalities (in-plane no GPS, in-plane with GPS, out-of-plane no GPS, out-of-plane with GPS) for a total of 12 attempts. The success or failure was judged by the ability to aspirate a simulated blood solution from the model. The time to successful puncture was also recorded. A poststudy validated NASA Task Load Index workload questionnaire was conducted to assess the student's perceptions of the two different techniques. A total of 30 students completed the study. There was no significant difference seen in the mean times of vascular access for each of the modalities. Higher success rates for vascular access using the GPS for both the in-plane (94% vs 91%) and the out-of-plane (86% vs 70%) views were observed; however, this was not statistically significant. The students perceived the mental demand (median 12.0 vs 14.00; P = .035) and effort to be lower (mean 11.25 vs 14.00; P = .044) as well as the performance to be higher (mean 15.50 vs 14.00; P = .041) for the GPS vs the traditional ultrasound-guided technique. Students also perceived their ability to access vessels increased with the aid of the GPS (7.00 vs 6.50; P = .007). The majority of students expressed a preference for GPS (26/30, 87%) as opposed to the traditional counterpart. Use of the novel SonixGPS needle-tracking ultrasound system (UltraSonix, Richmond, BC, Canada) was not associated with a higher success rate of vascular puncture compared with the traditional ultrasound-guided technique. Assessment of mental task load significantly favored the use of the ultrasound GPS over the traditional ultrasound technique. Copyright © 2013 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.
Paraffin-gel tissue-mimicking material for ultrasound-guided needle biopsy phantom.
Vieira, Sílvio L; Pavan, Theo Z; Junior, Jorge E; Carneiro, Antonio A O
2013-12-01
Paraffin-gel waxes have been investigated as new soft tissue-mimicking materials for ultrasound-guided breast biopsy training. Breast phantoms were produced with a broad range of acoustical properties. The speed of sound for the phantoms ranged from 1425.4 ± 0.6 to 1480.3 ± 1.7 m/s at room temperature. The attenuation coefficients were easily controlled between 0.32 ± 0.27 dB/cm and 2.04 ± 0.65 dB/cm at 7.5 MHz, depending on the amount of carnauba wax added to the base material. The materials do not suffer dehydration and provide adequate needle penetration, with a Young's storage modulus varying between 14.7 ± 0.2 kPa and 34.9 ± 0.3 kPa. The phantom background material possesses long-term stability and can be employed in a supine position without changes in geometry. These results indicate that paraffin-gel waxes may be promising materials for training radiologists in ultrasound biopsy procedures. Copyright © 2013 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Laser Generated Leaky Acoustic Waves for Needle Visualization.
Wu, Kai-Wen; Wang, Yi-An; Li, Pai-Chi
2018-04-01
Ultrasound (US)-guided needle operation is usually used to visualize both tissue and needle position such as tissue biopsy and localized drug delivery. However, the transducer-needle orientation is limited due to reflection of the acoustic waves. We proposed a leaky acoustic wave method to visualize the needle position and orientation. Laser pulses are emitted on top of the needle to generate acoustic waves; then, these acoustic waves propagate along the needle surface. Leaky wave signals are detected by the US array transducer. The needle position can be calculated by phase velocities of two different wave modes and their corresponding emission angles. In our experiments, a series of needles was inserted into a tissue mimicking phantom and porcine tissue to evaluate the accuracy of the proposed method. The results show that the detection depth is up to 51 mm and the insertion angle is up to 40° with needles of different diameters. It is demonstrated that the proposed approach outperforms the conventional B-mode US-guided needle operation in terms of the detection range while achieving similar accuracy. The proposed method reveals the potentials for further clinical applications.
Mullins, Cormac F; O'Brien, Conor; O'Connor, Therese C
2017-05-15
The quadratus lumborum (QL) block facilitates the administration of anaesthesia to the anterior abdominal wall. The use of ultrasound (US) improves the accuracy of the QL block and reduces the risk of adverse events. Electromyography (EMG) in combination with US for muscle plane blocks has not been described previously. We postulated that the addition of EMG-guided needle positioning might assist the execution of this block. This case report describes the first use of combined needle EMG and US to carry out a QL block performed for postoperative analgesia following an open appendicectomy. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
NASA Astrophysics Data System (ADS)
Hrinivich, W. Thomas; Hoover, Douglas A.; Surry, Kathleen; Edirisinghe, Chandima; Montreuil, Jacques; D'Souza, David; Fenster, Aaron; Wong, Eugene
2016-03-01
Background: High-dose-rate brachytherapy (HDR-BT) is a prostate cancer treatment option involving the insertion of hollow needles into the gland through the perineum to deliver a radioactive source. Conventional needle imaging involves indexing a trans-rectal ultrasound (TRUS) probe in the superior/inferior (S/I) direction, using the axial transducer to produce an image set for organ segmentation. These images have limited resolution in the needle insertion direction (S/I), so the sagittal transducer is used to identify needle tips, requiring a manual registration with the axial view. This registration introduces a source of uncertainty in the final segmentations and subsequent treatment plan. Our lab has developed a device enabling 3D-TRUS guided insertions with high S/I spatial resolution, eliminating the need to align axial and sagittal views. Purpose: To compare HDR-BT needle tip localization accuracy between 2D and 3D-TRUS. Methods: 5 prostate cancer patients underwent conventional 2D TRUS guided HDR-BT, during which 3D images were also acquired for post-operative registration and segmentation. Needle end-length measurements were taken, providing a gold standard for insertion depths. Results: 73 needles were analyzed from all 5 patients. Needle tip position differences between imaging techniques was found to be largest in the S/I direction with mean+/-SD of -2.5+/-4.0 mm. End-length measurements indicated that 3D TRUS provided statistically significantly lower mean+/-SD insertion depth error of -0.2+/-3.4 mm versus 2.3+/-3.7 mm with 2D guidance (p < .001). Conclusions: 3D TRUS may provide more accurate HDR-BT needle localization than conventional 2D TRUS guidance for the majority of HDR-BT needles.
Needle segmentation using 3D Hough transform in 3D TRUS guided prostate transperineal therapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Qiu Wu; Imaging Research Laboratories, Robarts Research Institute, Western University, London, Ontario N6A 5K8; Yuchi Ming
Purpose: Prostate adenocarcinoma is the most common noncutaneous malignancy in American men with over 200 000 new cases diagnosed each year. Prostate interventional therapy, such as cryotherapy and brachytherapy, is an effective treatment for prostate cancer. Its success relies on the correct needle implant position. This paper proposes a robust and efficient needle segmentation method, which acts as an aid to localize the needle in three-dimensional (3D) transrectal ultrasound (TRUS) guided prostate therapy. Methods: The procedure of locating the needle in a 3D TRUS image is a three-step process. First, the original 3D ultrasound image containing a needle is cropped;more » the cropped image is then converted to a binary format based on its histogram. Second, a 3D Hough transform based needle segmentation method is applied to the 3D binary image in order to locate the needle axis. The position of the needle endpoint is finally determined by an optimal threshold based analysis of the intensity probability distribution. The overall efficiency is improved through implementing a coarse-fine searching strategy. The proposed method was validated in tissue-mimicking agar phantoms, chicken breast phantoms, and 3D TRUS patient images from prostate brachytherapy and cryotherapy procedures by comparison to the manual segmentation. The robustness of the proposed approach was tested by means of varying parameters such as needle insertion angle, needle insertion length, binarization threshold level, and cropping size. Results: The validation results indicate that the proposed Hough transform based method is accurate and robust, with an achieved endpoint localization accuracy of 0.5 mm for agar phantom images, 0.7 mm for chicken breast phantom images, and 1 mm for in vivo patient cryotherapy and brachytherapy images. The mean execution time of needle segmentation algorithm was 2 s for a 3D TRUS image with size of 264 Multiplication-Sign 376 Multiplication-Sign 630 voxels. Conclusions: The proposed needle segmentation algorithm is accurate, robust, and suitable for 3D TRUS guided prostate transperineal therapy.« less
Treatment of supraspinatus tendinopathy with ultrasound guided dry needling
Settergren, Roy
2013-01-01
Objective The purpose of this case study is to describe the treatment of a patient with tendinopathy using sonographically guided dry needling. Tendinopathies are a highly prevalent problem in musculoskeletal medicine, and no one form of treatment has gained universal acceptance as being superior to another. Clinical Features A 30-year-old woman with a 4-month history of anterolateral right shoulder pain was diagnosed with supraspinatus tendinopathy upon physical examination, which was confirmed with diagnostic sonography. Intervention and Outcome Sonography was used to guide an acupuncture needle into the pathologic tissue to induce a humoral healing response. Therapeutic exercise was also prescribed. At 10-day follow-up, increased echogenicity was found in the previously heterogenous hypoechoic areas. The patient also experienced a subjective resolution of her shoulder pain, which did not return with increased physical activity. Conclusions Sonographically guided dry needling was shown to be beneficial for this patient as evident by sonographic changes pre- and postprocedure. PMID:23997721
Plaikner, Michaela; Gruber, Hannes; Henninger, Benjamin; Gruber, Leonhard; Kosiol, Juana; Loizides, Alexander
2016-03-01
We report on a rare case of an atypical located aneurysmal bone cyst (ABC) in the patella presenting with pathological fracture after trauma. Using all available diagnostic modalities and by means of ultrasound-guided core-needle biopsy an unclear and suspected pathological fractured cystic bone lesion in the patella of a young man could be further clarified. The acquired images suggested the diagnosis of a pathological fractured aneurysmal bone cyst after mild trauma. However, due to the extraordinary location and clinical presentation the diagnosis was secured by means of ultrasound-guided biopsy through a small cortical gap. As shown in this rare case of an atypical aneurysmal bone cyst of the patella, the quite seldom but sometimes possible ultrasound-guided biopsy of intraosseous lesions can help to achieve the diagnostic clarification and should also be taken into account as a non-standard procedure.
Osorio, Joseph A; Breshears, Jonathan D; Arnaout, Omar; Simon, Neil G; Hastings-Robinson, Ashley M; Aleshi, Pedram; Kliot, Michel
2015-09-01
OBJECT The objective of this study was to provide a technique that could be used in the preoperative period to facilitate the surgical exploration of peripheral nerve pathology. METHODS The authors describe a technique in which 1) ultrasonography is used in the immediate preoperative period to identify target peripheral nerves, 2) an ultrasound-guided needle electrode is used to stimulate peripheral nerves to confirm their position, and then 3) a methylene blue (MB) injection is performed to mark the peripheral nerve pathology to facilitate surgical exploration. RESULTS A cohort of 13 patients with varying indications for peripheral nerve surgery is presented in which ultrasound guidance, stimulation, and MB were used to localize and create a road map for surgeries. CONCLUSIONS Preoperative ultrasound-guided MB administration is a promising technique that peripheral nerve surgeons could use to plan and execute surgery.
Cardoso-Coelho, Lívio Portela; Borges, Rafael Soares; Alencar, Airlane Pereira; Cardoso-Campos-Verdes, Larysse Maira; da Silva-Sampaio, João Paulo; Borges, Umbelina Soares; Gebrim, Luiz Henrique; da Silva, Benedito Borges
2017-01-01
The replacement of sentinel lymph node biopsy (SNB) by ultrasound-guided fine-needle aspiration (US-guided FNA) cytology of axillary lymph nodes is controversial, despite the simplicity and reduced cost of the latter. In the present study, US-guided FNA was performed in 27 patients with early-stage breast cancer for comparison with SNB. Data were analyzed by calculation of sample proportions. Tumor subtypes included invasive ductal carcinoma (85%), invasive lobular carcinoma (7%), and tubular and metaplastic carcinoma (4%). FNA had a sensitivity of 45%, specificity of 100%, positive predictive value of 100% and a negative predictive value of 73%. Axillary lymph node cytology obtained by US guided-FNA in patients with breast cancer had a specificity similar to that of sentinel lymph node histopathology in the presence of axillary node metastases. However, when lymph node cytology is negative, it does not exclude the existence of metastatic implants, due to its low sensitivity in comparison to sentinel lymph node histopathology. PMID:28521436
Zhou, Jian-hua; Shan, Hong-bo; Ou, Wei; Mo, Yun-xian; Xiang, Jin; Wang, Yu; Wang, Si-yu
2018-01-01
Based on the option that ultrasound-guided core needle biopsy (US-CNB) of the enhanced portion of anterior mediastinal masses (AMMs) identified by contrast-enhanced ultrasound (CEUS) would harvest viable tissue and benefit the histological diagnoses, a retrospective study was performed to elucidate the correlation between the prebiopsy CEUS and diagnostic yield of AMMs and found that CEUS potentially improved the diagnostic yield of AMMs compared with conventional US with a significant increase in the cellularity of samples. Furthermore, the marginal blood flow signals and absence of necrosis can predict the diagnostic yield of AMM. It was concluded that US-CNB of the viable part of AMMs, as verified by CEUS, was able to harvest sufficient tissue with more cellularity that could be used for ancillary studies and improve the diagnostic yield. And CEUS was recommended to those patients with AMMs undergoing repeated US-CNB, with the absence of marginal blood signals or presence of necrosis. PMID:29581992
Liu, Yang; Glass, Nancy L; Glover, Chris D; Power, Robert W; Watcha, Mehernoor F
2013-12-01
Ultrasound-guided regional anesthesia (UGRA) skills are traditionally obtained by supervised performance on patients, but practice on phantom models improves success. Currently available models are expensive or use perishable products, for example, olive-in-chicken breasts (OCB). We constructed 2 inexpensive phantom (transparent and opaque) models with readily available nonperishable products and compared the process of learning UGRA skills by novice practitioners on these models with the OCB model. Three experts first established criteria for a satisfactory completion of the simulated UGRA task in the 3 models. Thirty-six novice trainees (<20 previous UGRA experience) were randomly assigned to perform a UGRA task on 1 of 3 models-the transparent, opaque, and OCB models, where the hyperechoic target was identified, a needle was advanced to it under ultrasound guidance, fluid was injected, and images were saved. We recorded the errors during task completion, number of attempts and needle passes, and the time for target identification and needle placement until the predetermined benchmark of 3 consecutive successful UGRA simulations was accomplished. The number of errors, needle passes, and time for task completion per attempt progressively decreased in all 3 groups. However, failure to identify the target and to visualize the needle on the ultrasound image occurred more frequently with the OCB model. The time to complete simulator training was shortest with the transparent model, owing to shorter target identification times. However, trainees were less likely to agree strongly that this model was realistic for teaching UGRA skills. Training on inexpensive synthetic simulation models with no perishable products permits learning of UGRA skills by novices. The OCB model has disadvantages of containing potentially infective material, requires refrigeration, cannot be used after multiple needle punctures, and is associated with more failures during simulated UGRA. Direct visualization of the target in the transparent model allows the trainee to focus on needle insertion skills, but the opaque model may be more realistic for learning target identification skills required when UGRA is performed on real patients in the operating room.
Daswani, Ravi; Kumar, Ashish; Singla, Vikas; Kaur, Gagandeep; Sharma, Praveen; Bansal, Naresh; Arora, Anil
2018-06-01
The gold-standard for diagnosis is growth of Mycobacterium tuberculosis on ascitic fluid or peritoneal culture. Due to the non-specific signs and symptoms of disease, its early diagnosis is difficult, especially in patients with decompensated cirrhosis. The reported sensitivity of ascitic fluid is low and to obtain tissue for peritoneal biopsy in patients with cirrhosis is difficult. Endoscopic ultrasound (EUS) guided fine needle aspiration (FNA) is a good alternative to obtain peritoneal tissue for establishing the diagnosis of peritoneal TB. To assess the role of EUS-FNA in the diagnosis of peritoneal tuberculosis in patients with decompensated cirrhosis. Consecutive patients with peritoneal thickening, ascites and decompensated cirrhosis underwent EUS-FNA from the thickened omentum. Presence of granuloma or demonstration of acid fast bacilli was diagnostic of peritoneal tuberculosis. A total of 5 patients with CLD underwent EUS-FNA from omentum. FNA cytology revealed granuloma with multinucleated cells in all patients (100%) and AFB stain was positive in 2 of them (40%). We hereby report the use of EUS guided fine needle aspiration (FNA) of peritoneum as a newer, safe and unexplored technique for diagnosis of peritoneal TB.
Ultrasound-guided three-dimensional needle steering in biological tissue with curved surfaces
Abayazid, Momen; Moreira, Pedro; Shahriari, Navid; Patil, Sachin; Alterovitz, Ron; Misra, Sarthak
2015-01-01
In this paper, we present a system capable of automatically steering a bevel-tipped flexible needle under ultrasound guidance toward a physical target while avoiding a physical obstacle embedded in gelatin phantoms and biological tissue with curved surfaces. An ultrasound pre-operative scan is performed for three-dimensional (3D) target localization and shape reconstruction. A controller based on implicit force control is developed to align the transducer with curved surfaces to assure the maximum contact area, and thus obtain an image of sufficient quality. We experimentally investigate the effect of needle insertion system parameters such as insertion speed, needle diameter and bevel angle on target motion to adjust the parameters that minimize the target motion during insertion. A fast sampling-based path planner is used to compute and periodically update a feasible path to the target that avoids obstacles. We present experimental results for target reconstruction and needle insertion procedures in gelatin-based phantoms and biological tissue. Mean targeting errors of 1.46 ± 0.37 mm, 1.29 ± 0.29 mm and 1.82 ± 0.58 mm are obtained for phantoms with inclined, curved and combined (inclined and curved) surfaces, respectively, for insertion distance of 86–103 mm. The achieved targeting errors suggest that our approach is sufficient for targeting lesions of 3 mm radius that can be detected using clinical ultrasound imaging systems. PMID:25455165
Chen, Yongchao; Zhu, Youzhi; Zhang, Yu; Zhang, Zixuan; Lian, Juan; Luo, Fucheng; Deng, Xuefei; Wong, Kelvin K L
2016-02-06
Double injection of blood into cisterna magna using a rabbit model results in cerebral vasospasm. An unacceptably high mortality rate tends to limit the application of model. Ultrasound guided puncture can provide real-time imaging guidance for operation. The aim of this paper is to establish a safe and effective rabbit model of cerebral vasospasm after subarachnoid hemorrhage with the assistance of ultrasound medical imaging. A total of 160 New Zealand white rabbits were randomly divided into four groups of 40 each: (1) manual control group, (2) manual model group, (3) ultrasound guided control group, and (4) ultrasound guided model group. The subarachnoid hemorrhage was intentionally caused by double injection of blood into their cisterna magna. Then, basilar artery diameters were measured using magnetic resonance angiography before modeling and 5 days after modeling. The depth of needle entering into cisterna magna was determined during the process of ultrasound guided puncture. The mortality rates in manual control group and model group were 15 and 23 %, respectively. No rabbits were sacrificed in those two ultrasound guided groups. We found that the mortality rate in ultrasound guided groups decreased significantly compared to manual groups. Compared with diameters before modeling, the basilar artery diameters after modeling were significantly lower in manual and ultrasound guided model groups. The vasospasm aggravated and the proportion of severe vasospasms was greater in ultrasound guided model group than that of manual group. In manual model group, no vasospasm was found in 8 % of rabbits. The ultrasound guided double injection of blood into cisterna magna is a safe and effective rabbit model for treatment of cerebral vasospasm.
NASA Astrophysics Data System (ADS)
Rogers, Albert J.; Light, Edward D.; von Allmen, Daniel; Smith, Stephen W.
2009-02-01
Two studies have been conducted using real time 3D ultrasound and an automated robot system for carrying out surgical tasks. The first task is to perform a breast lesion biopsy automatically after detection by ultrasound. Combining 3D ultrasound with traditional mammography allows real time guidance of the biopsy needle. Image processing techniques analyze volumes to calculate the location of a target lesion. This position was converted into the coordinate system of a three axis robot which moved a needle probe to touch the lesion. The second task is to remove shrapnel from a tissue phantom autonomously. In some emergency situations, shrapnel detection in the body is necessary for quick treatment. Furthermore, small or uneven shrapnel geometry may hinder location by typical ultrasound imaging methods. Vibrations and small displacements can be induced in ferromagnetic shrapnel by a variable electromagnet. We used real time 3D color Doppler to locate this motion for 2 mm long needle fragments and determined the 3D position of the fragment in the scanner coordinates. The rms error of the image guided robot for 5 trials was 1.06 mm for this task which was accomplished in 76 seconds.
NASA Astrophysics Data System (ADS)
Zhang, Haichong K.; Lin, Melissa; Kim, Younsu; Paredes, Mateo; Kannan, Karun; Patel, Nisu; Moghekar, Abhay; Durr, Nicholas J.; Boctor, Emad M.
2017-03-01
Lumbar punctures (LPs) are interventional procedures used to collect cerebrospinal fluid (CSF), a bodily fluid needed to diagnose central nervous system disorders. Most lumbar punctures are performed blindly without imaging guidance. Because the target window is small, physicians can only accurately palpate the appropriate space about 30% of the time and perform a successful procedure after an average of three attempts. Although various forms of imaging based guidance systems have been developed to aid in this procedure, these systems complicate the procedure by including independent image modalities and requiring image-to-needle registration to guide the needle insertion. Here, we propose a simple and direct needle insertion platform utilizing a single ultrasound element within the needle through dynamic sensing and imaging. The needle-shaped ultrasound transducer can not only sense the distance between the tip and a potential obstacle such as bone, but also visually locate structures by combining transducer location tracking and back projection based tracked synthetic aperture beam-forming algorithm. The concept of the system was validated through simulation first, which revealed the tolerance to realistic error. Then, the initial prototype of the single element transducer was built into a 14G needle, and was mounted on a holster equipped with a rotation tracking encoder. We experimentally evaluated the system using a metal wire phantom mimicking high reflection bone structures and an actual spine bone phantom with both the controlled motion and freehand scanning. An ultrasound image corresponding to the model phantom structure was reconstructed using the beam-forming algorithm, and the resolution was improved compared to without beam-forming. These results demonstrated the proposed system has the potential to be used as an ultrasound imaging system for lumbar puncture procedures.
Prostate Enlargement: Benign Prostatic Hyperplasia (BPH)
... such as ultrasound, a computerized tomography scan, or magnetic resonance imaging to guide the biopsy needle into ... heats and destroys selected portions of prostate tissue. Shields protect the urethra from heat damage. Transurethral microwave ...
Ieni, Antonio; Barresi, Valeria; Todaro, Paolo; Caruso, Rosario Alberto; Tuccari, Giovanni
2015-01-01
In the present review we have analyzed the clinical applications of endoscopic ultrasound-guided-fine-needle-aspiration (EUS-FNA) and the methodological aspects obtained by cell-block procedure (CBP) in the diagnostic approach to the gastrointestinal neoplastic pathology. CBP showed numerous advantages in comparison to the cytologic routine smears; in particular, better preservation of cell architecture, achievement of routine haematoxylin-eosin staining equivalent to histological slides and possibility to perform immunohistochemistry or molecular analyses represented the most evident reasons to choose this method. Moreover, by this approach, the differential diagnosis of solid gastrointestinal neoplasias may be more easily achieved and the background of contaminant non-neoplastic gastrointestinal avoided. Finally, biological samples collected by EUS-FNA CBP-assisted should be investigated in order to identify and quantify further potential molecular markers. PMID:26322154
von Bartheld, Martin B; Annema, Jouke T
2015-12-01
Endosonography is being implemented rapidly in pulmonary medicine for the diagnosis and staging of lung cancer, the assessment of sarcoidosis, and the assessment of mediastinal lesions. Although serious adverse events (SAEs) have been described, safety data outside cohort studies are scarce. To assess the SAE and mortality rate of EUS-guided FNA (EUS-FNA) and endobronchial ultrasound guided transbronchial needle aspiration (EBUS-TBNA) for mediastinal and/or hilar analysis. Nationwide, retrospective survey by using questionnaires. All hospitals in the Netherlands. All patients undergoing EUS-FNA and EBUS-TBNA for intrathoracic analysis in the period 1999 to 2011. EUS-FNA and EBUS-TBNA. Occurrence of fatal outcomes and SAEs. Detailed information was obtained for each reported case, and all cases were reviewed independently by 2 investigators, including identification of risk factors. All 89 hospitals (100%) responded. An estimated 14,075 EUS-FNA and 2675 EBUS procedures were performed. Seven patients died after endosonography (5 EUS-FNA, 2 EBUS [mortality rate 0.04%]). All fatalities occurred in patients of poor performance status (American Society of Anesthesiologists Physical Status Classification System score of III/IV). Twenty-five SAEs were reported (22 EUS-FNA, 3 EBUS [SAE rate of 0.15%; EUS-FNA 0.16%, EBUS 0.11%]). SAEs were mostly (64%) of infectious origin. No specific risk factors for infectious adverse events could be identified. Retrospective study, possible recall bias, overrepresentation of EUS-FNA cases. Endosonography appears to be a safe technique for the analysis of mediastinal and/or hilar lesions. Poor performance status is a risk factor for fatal outcomes. Mediastinitis and/or mediastinal abscess formation is rare but is a potential and dangerous adverse event of endosonography. Copyright © 2015 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.
Characterization of tissue-simulating phantom materials for ultrasound-guided needle procedures
NASA Astrophysics Data System (ADS)
Buchanan, Susan; Moore, John; Lammers, Deanna; Baxter, John; Peters, Terry
2012-02-01
Needle biopsies are standard protocols that are commonly performed under ultrasound (US) guidance or computed tomography (CT)1. Vascular access such as central line insertions, and many spinal needle therapies also rely on US guidance. Phantoms for these procedures are crucial as both training tools for clinicians and research tools for developing new guidance systems. Realistic imaging properties and material longevity are critical qualities for needle guidance phantoms. However, current commercially available phantoms for use with US guidance have many limitations, the most detrimental of which include harsh needle tracks obfuscating US images and a membrane comparable to human skin that does not allow seepage of inner media. To overcome these difficulties, we tested a variety of readily available media and membranes to evaluate optimal materials to fit our current needs. It was concluded that liquid hand soap was the best medium, as it instantly left no needle tracks, had an acceptable depth of US penetration and portrayed realistic imaging conditions, while because of its low leakage, low cost, acceptable durability and transparency, the optimal membrane was 10 gauge vinyl.
Factors influencing discomfort during anterior ultrasound-guided injection for hip arthrography.
Hsu, Yi-Chih; Wu, Yu-Cheng; Kao, Hao-Lun; Pan, Ru-Yu; Lee, Meei-Shyuan; Huang, Guo-Shu
2013-09-01
Although ultrasound (US)-guided injection techniques for magnetic resonance arthrography of the hip have been used with increasing frequency to diagnose internal joint derangements, little is known about patient tolerance, which is relevant information for patients. The objective of this study was to evaluate prospectively the association between possible influencing factors and discomfort felt during the performance of anterior US-guided injection techniques targeting the femoral head-neck junction during hip arthrography. Forty-four consecutive patients (21 women and 23 men; mean age, 41 years) undergoing magnetic resonance hip arthrography were sequentially assigned to receive injection alternating between fixed and freehand US-guided injection. Discomfort was assessed using a visual analog scale and relative ratings. Patient body mass index, extra-articular contrast leakage, the duration of the procedure, the needle advancement distance, and the fixed trajectory of the needle were assessed. Pearson's correlation coefficients and multiple logistic regression analysis were used to determine the association. Puncture was successfully accomplished in all cases, and no relevant complications were reported. The only significant relationships were between discomfort and the time required for needle manipulation (r = 0.8) and fixed US-guided injection (r = 0.6; p < 0.001). Compared with the freehand technique, the fixed technique resulted in significantly less pain and took significantly less time to perform (p < 0.001). The procedure time during needle manipulation in the fixed US-guided injections (4.0 ± 0.9 seconds) was significantly less than that in the freehand US-guided injections (19.4 ± 17.6 seconds; p < 0.001). No significant relationships were found between discomfort and other parameters (r < 0.3, p > 0.05). The procedure time appears to be the most important factor influencing patient discomfort. Fixed US-guided injection is a time-saving technique that alleviates procedure-related discomfort. Copyright © 2013. Published by Elsevier B.V.
Lin, Michael; Hair, Clark D.; Green, Linda K.; Vela, Stacie A.; Patel, Kalpesh K.; Qureshi, Waqar A.; Shaib, Yasser H.
2014-01-01
Background: Endoscopic ultrasound (EUS)-guided fine needle aspiration (FNA) with bedside cytopathology is the gold standard for assessment of pancreatic, subepithelial, and other lesions in close proximity to the gastrointestinal tract, but it is time-consuming, has certain diagnostic limitations, and bedside cytopathology is not widely available. Aims: The goal of this study is to compare the diagnostic yield of EUS-guided FNA with on-site cytopathology and EUS-guided core biopsy. Methods: Twenty-six patients with gastrointestinal mass lesions requiring biopsy at a tertiary medical center were included in this retrospective analysis of a prospective cohort. Two core biopsies were taken using a 22 gauge needle followed by FNA guided by a bedside cytopathologist at the same endoscopic session. The diagnostic yield and test characteristics of EUS core biopsy and EUS FNA with bedside cytopathology were examined. Results: The mean number of passes was 3.2 for FNA, and the mean procedure time was 39.4 minutes. The final diagnosis was malignant in 92.3 %. Sensitivity and specificity were 83 % and 100 %, respectively, for FNA, and 91.7 % and 100 %, respectively, for core biopsy. Diagnostic accuracy was 92.3 % for FNA and 84.6 % for core biopsy. The two approaches were in agreement in 88.4 % with a kappa statistic of 0.66 (95 % confidence interval 0.33 – 0.99). Conclusions: An approach using two passes with a core biopsy needle is comparable to the current gold standard of FNA with bedside cytopathology. The performance of two core biopsies is time-efficient and could represent a good alternative to FNA with bedside cytopathology. PMID:26135096
Probabilistic registration of an unbiased statistical shape model to ultrasound images of the spine
NASA Astrophysics Data System (ADS)
Rasoulian, Abtin; Rohling, Robert N.; Abolmaesumi, Purang
2012-02-01
The placement of an epidural needle is among the most difficult regional anesthetic techniques. Ultrasound has been proposed to improve success of placement. However, it has not become the standard-of-care because of limitations in the depictions and interpretation of the key anatomical features. We propose to augment the ultrasound images with a registered statistical shape model of the spine to aid interpretation. The model is created with a novel deformable group-wise registration method which utilizes a probabilistic approach to register groups of point sets. The method is compared to a volume-based model building technique and it demonstrates better generalization and compactness. We instantiate and register the shape model to a spine surface probability map extracted from the ultrasound images. Validation is performed on human subjects. The achieved registration accuracy (2-4 mm) is sufficient to guide the choice of puncture site and trajectory of an epidural needle.
Khan, Ajmal; Nath, Alok; Lal, Hira; Krishnani, Narendra; Agarwal, Aarti
2018-01-01
In the modern era, real-time imaging-guided transbronchial needle aspiration (TBNA) has completely replaced the traditional surgical approaches to sample the mediastinal lesions for diagnosis and cancer staging. However, there is a limited role of these innovations in the presence of critical airway narrowing due to a further decrease in cross-sectional area of the airway proportionate to the outer diameters of the scope. Rigid TBNA with airway control by rigid bronchoscopy is one alternative which can be used for mediastinal sampling when modern technique is impracticable. Herein, we report the use of rigid TBNA, an underutilized old method to sample the mediastinal lesion in a patient with severe orthopnea secondary to tracheal compression by mediastinal mass.
Louwerens, Jan K G; Veltman, Ewout S; van Noort, Arthur; van den Bekerom, Michel P J
2016-01-01
The objectives of this comprehensive quantitative review of the treatment of calcific tendinopathy of the rotator cuff were to investigate if there is a sustainable positive effect on outcomes after treatment with high-energy extracorporeal shockwave therapy (ESWT) or ultrasound (US)-guided needling and to compare these results with those of treatment with arthroscopic surgery. The PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines were followed to conduct this review. A systematic literature search was conducted in December 2014 to identify relevant clinical articles in peer-reviewed journals with at least 6 months' follow-up. Each article was scored using the Coleman Methodology Score. The primary endpoints were functional outcome and radiologic change in the size of the calcific deposit. Twenty-two studies were included (1,258 shoulders). The mean Coleman Methodology Score for the included studies was 77.1 ± 9.1. Overall, good to excellent clinical outcomes were achieved after treatment with either high-energy ESWT, US-guided needling, or arthroscopic surgery, with an improvement in the Constant-Murley score ranging between 26.3 and 41.5 points after 1 year. No severe side effects or long-term complications were encountered. Patients can achieve good to excellent clinical outcomes after high-energy ESWT, US-guided needling, and arthroscopy for calcific tendinopathy of the shoulder. Side effects and post-treatment complications should be taken into account when a decision is being made for each individual patient. Physicians should consider high-energy ESWT and US-guided needling as minimally invasive treatment options when primary conservative treatment fails. Arthroscopy can safely be used as a very effective but more invasive secondary option, although the extent of deposit removal and the additional benefit of subacromial decompression remain unclear. Level IV, systematic review of Level I, II, and IV studies. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Characterization of optically actuated MRI-compatible active needles for medical interventions
NASA Astrophysics Data System (ADS)
Black, Richard J.; Ryu, Seokchang; Moslehi, Behzad; Costa, Joannes M.
2014-03-01
The development of a Magnetic Resonance Imaging (MRI) compatible optically-actuated active needle for guided percutaneous surgery and biopsy procedures is described. Electrically passive MRI-compatible actuation in the small diameter needle is provided by non-magnetic materials including a shape memory alloy (SMA) subject to precise fiber laser operation that can be from a remote (e.g., MRI control room) location. Characterization and optimization of the needle is facilitated using optical fiber Bragg grating (FBG) temperature sensors arrays. Active bending of the needle during insertion allows the needle to be accurately guided to even relatively small targets in an organ while avoiding obstacles and overcoming undesirable deviations away from the planned path due to unforeseen or unknowable tissue interactions. This feature makes the needle especially suitable for use in image-guided surgical procedures (ranging from MRI to CT and ultrasound) when accurate targeting is imperative for good treatment outcomes. Such interventions include reaching small tumors in biopsies, delineating freezing areas in, for example, cryosurgery and improving the accuracy of seed placement in brachytherapy. Particularly relevant are prostate procedures, which may be subject to pubic arch interference. Combining diagnostic imaging and actuation assisted biopsy into one treatment can obviate the need for a second exam for guided biopsy, shorten overall procedure times (thus increasing operating room efficiencies), address healthcare reimbursement constraints and, most importantly, improve patient comfort and clinical outcomes.
NASA Astrophysics Data System (ADS)
Stegehuis, Paulien L.; Boogerd, Leonora S. F.; Inderson, Akin; Veenendaal, Roeland A.; van Gerven, P.; Bonsing, Bert A.; Sven Mieog, J.; Amelink, Arjen; Veselic, Maud; Morreau, Hans; van de Velde, Cornelis J. H.; Lelieveldt, Boudewijn P. F.; Dijkstra, Jouke; Robinson, Dominic J.; Vahrmeijer, Alexander L.
2017-02-01
Endoscopic ultrasound-guided fine needle aspirations (EUS-FNA) of pancreatic masses suffer from sample errors and low-negative predictive values. Fiber-optic spectroscopy in the visible to near-infrared wavelength spectrum can noninvasively extract physiological parameters from tissue and has the potential to guide the sampling process and reduce sample errors. We assessed the feasibility of single fiber (SF) reflectance spectroscopy measurements during EUS-FNA of pancreatic masses and its ability to distinguish benign from malignant pancreatic tissue. A single optical fiber was placed inside a 19-gauge biopsy needle during EUS-FNA and at least three reflectance measurements were taken prior to FNA. Spectroscopy measurements did not cause any related adverse events and prolonged procedure time with ˜5 min. An accurate correlation between spectroscopy measurements and cytology could be made in nine patients (three benign and six malignant). The oxygen saturation and bilirubin concentration were significantly higher in benign tissue compared with malignant tissue (55% versus 21%, p=0.038; 166 μmol/L versus 17 μmol/L, p=0.039, respectively). To conclude, incorporation of SF spectroscopy during EUS-FNA was feasible, safe, and relatively quick to perform. The optical properties of benign and malignant pancreatic tissue are different, implying that SF spectroscopy can potentially guide the FNA sampling.
Ultrasound-guided central venous access using Google Glass.
Wu, Teresa S; Dameff, Christian J; Tully, Jeffrey L
2014-12-01
The use of ultrasound during invasive bedside procedures is quickly becoming the standard of care. Ultrasound machine placement during procedures often requires the practitioner to turn their head during the procedure to view the screen. Such turning has been implicated in unintentional hand movements in novices. Google Glass is a head-mounted computer with a specialized screen capable of projecting images and video into the view of the wearer. Such technology may help decrease unintentional hand movements. Our aim was to evaluate whether or not medical practitioners at various levels of training could use Google Glass to perform an ultrasound-guided procedure, and to explore potential advantages of this technology. Forty participants of varying training levels were randomized into two groups. One group used Google Glass to perform an ultrasound-guided central line. The other group used traditional ultrasound during the procedure. Video recordings of eye and hand movements were analyzed. All participants from both groups were able to complete the procedure without difficulty. Google Glass wearers took longer to perform the procedure at all training levels (medical student year 1 [MS1]: 193 s vs. 77 s, p > 0.5; MS4: 197s vs. 91s, p ≤ 0.05; postgraduate year 1 [PGY1]: 288s vs. 125 s, p > 0.5; PGY3: 151 s vs. 52 s, p ≤ 0.05), and required more needle redirections (MS1: 4.4 vs. 2.0, p > 0.5; MS4: 4.8 vs. 2.8, p > 0.5; PGY1: 4.4 vs. 2.8, p > 0.5; PGY3: 2.0 vs. 1.0, p > 0.5). In this study, it was possible to perform ultrasound-guided procedures with Google Glass. Google Glass wearers, on average, took longer to gain access, and had more needle redirections, but less head movements were noted. Copyright © 2014 Elsevier Inc. All rights reserved.
The additional role of Xpert MTB/RIF in the diagnosis of intrathoracic tuberculous lymphadenitis.
Lee, Jinwoo; Choi, Sun Mi; Lee, Chang-Hoon; Lee, Sang-Min; Yim, Jae-Joon; Yoo, Chul-Gyu; Kim, Young Whan; Han, Sung Koo; Park, Young Sik
2017-06-01
Diagnosis of intrathoracic tuberculosis (TB) lymphadenitis remains a challenge because of difficulties in obtaining adequate tissue and the lack of a sensitive test. Recently, Xpert MTB/RIF assay is being used for rapid diagnosis of pulmonary TB, but it has not yet been widely validated in intrathoracic TB lymphadenitis. The aim of this study was to assess the additional role of Xpert MTB/RIF in diagnosing intrathoracic TB lymphadenitis using endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) specimen. Consecutive patients who underwent Xpert MTB/RIF assay using EBUS-TBNA specimen from January 2012 and November 2013 at a tertiary referral hospital were recruited. Among them, the cases with malignant lymph nodes were excluded. Among 73 patients, 13 (17.8%) cases were diagnosed with intrathoracic TB lymphadenitis. In detail, 10 patients were diagnosed using conventional methods only (histology or AFB culture) and 3 patients were additionally diagnosed when adding Xpert MTB/RIF assay. The median time to diagnosis using Xpert MTB/RIF (1 day) was shorter than conventional methods (3 days for histology, 14 days for AFB culture). Rifampin resistance was not detected in any patients. In patients with enlarged intrathoracic lymph nodes and low suspicion of malignancy, combination of conventional diagnostic methods with Xpert MTB/RIF could lead to additional and rapid diagnosis of intrathoracic TB lymphadenitis. Copyright © 2017 Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.
Suzuki, Rei; Irisawa, Atsushi; Bhutani, Manoop S; Hikichi, Takuto; Takagi, Tadayuki; Shibukawa, Goro; Sato, Ai; Sato, Masaki; Ikeda, Tsunehiko; Watanabe, Ko; Nakamura, Jun; Annangi, Srinadh; Tasaki, Kazuhiro; Obara, Katsutoshi; Ohira, Hiromasa
2014-01-01
AIM: To evaluate the feasibility of using an automated spring-loaded needle device for endoscopic ultrasound (EUS)-guided abdominal paracentesis (EUS-P) to see if this would make it easier to puncture the mobile and lax gastric wall for EUS-P. METHODS: The EUS database and electronic medical records at Fukushima Medical University Hospital were searched from January 2001 to April 2011. Patients with a history of cancer and who underwent EUS-P using an automated spring-loaded needle device with a 22-gauge puncture needle were included. The needle was passed through the instrument channel and advanced through the gastrointestinal wall under EUS guidance into the echo-free space in the abdominal cavity and ascitic fluid was collected. The confirmed diagnosis of malignant ascites included positive cytology and results from careful clinical observation for at least 6 mo in patients with negative cytology. The technical success rate, cytology results and complications were evaluated. RESULTS: We found 11 patients who underwent EUS-P with an automated spring-loaded needle device. In 4 cases, ascites was revealed only with EUS but not in other imaging modalities. EUS-P was done in 7 other cases because there was minimal ascitic fluid and no safe window for percutaneous abdominal aspiration. Ascitic fluid was obtained in all cases by EUS-P. The average amount aspirated was 14.1 mL (range 0.5-38 mL) and that was sent for cytological exam. The etiology of ascitic fluid was benign in 5 patients and malignant in 6. In all cases, ascitic fluid was obtained with the first needle pass. No procedure-related adverse effects occurred. CONCLUSION: EUS-P with an automated spring-loaded needle device is a feasible and safe method for ascites evaluation. PMID:24567793
Gulay, Ucarli; Meltem, Turkay; Nadir, Sinikoglu Sitki; Aysin, Alagol
2015-01-01
The aim was to compare visibility of the spinal space in sitting and lateral positions, number of attempts, spinal needle depth, skin-dura mater distance and the possible complications; in application of spinal anesthesia, using ultrasound in pregnant patients scheduled to receive elective cesarean operations. The study was conducted prospective-randomly after receiving approval from the ethics committee and the patients' permission. ASA I-II 50 pregnant patients were divided into two groups. The patients in Group SP were those placed in a sitting position and the patients in Group LP were those placed in a lateral position. In both groups, the skin-dura mater distance was recorded through an out-of plane technique accompanied by ultrasound. The depth of the spinal needle was measured. The number of attempts, the level of attempts recorded. The degree of visibility of the vertebral space was observed through ultrasound and was numerically scored. Intraoperative and postoperative complications were recorded. There was no difference between the number of attempts, Modified Bromage Scale and mean measurements of skin-dura mater distance observed through ultrasound. The mean needle depths of Group LP were statistically found significantly higher than Group SP (p=0.002). Our study supports the notion that access to the skin-dura mater distance is longer in the lateral decubitus position when skin-dura mater distance is evaluated by measuring needle depth.
Yamamoto, Hiroto; Sakura, Shinichi; Wada, Minori; Shido, Akemi
2014-12-01
It is believed that local anesthetic injected to obtain circumferential spread around nerves produces a more rapid onset and successful blockade after some ultrasound-guided peripheral nerve blocks. However, evidence demonstrating this point is limited only to the popliteal sciatic nerve block, which is relatively easy to perform by via a high-frequency linear transducer. In the present study, we tested the hypothesis that multiple injections of local anesthetic to make circumferential spread would improve the rate of sensory and motor blocks compared with a single-injection technique for ultrasound-guided subgluteal sciatic nerve block, which is considered a relatively difficult block conducted with a low-frequency, curved-array transducer. Ninety patients undergoing knee surgery were divided randomly into 2 groups to receive the ultrasound-guided subgluteal approach to sciatic nerve block with 20 mL of 1.5% mepivacaine with epinephrine. For group M (the multiple-injection technique), the local anesthetic was injected to create circumferential spread around the sciatic nerve without limitation on the number of needle passes. For group S (the single-injection technique), the number of needle passes was limited to 1, and the local anesthetic was injected to create spread along the dorsal surface of the sciatic nerve, during which no adjustment of the needle tip was made. Sensory and motor blockade were assessed in double-blind fashion for 30 minutes after completion of the block. The primary outcome was sensory blockade of all sciatic components tested, including tibial, superficial peroneal, and sural nerves at 30 minutes after injection. Data from 86 patients (43 in each group) were analyzed. Block execution took more time for group M than group S. The proportion of patients with complete sensory blockade of all sciatic components at 30 minutes after injection was significantly larger for group M than group S (41.9% vs 16.3%, P = 0.018). Complete motor blockade of foot and toes extension also was observed more frequently in group M than in group S (67.4% vs 34.9%, P = 0.005 and 51.2% vs 25.6%, P = 0.027, respectively). When ultrasound-guided subgluteal sciatic nerve block is conducted, multiple injections of local anesthetic to make a circumferential spread around the sciatic nerve improve the rate of sensory and motor blocks compared with a single injection.
Mignon, Paul; Poignet, Philippe; Troccaz, Jocelyne
2018-05-29
Robotic control of needle bending aims at increasing the precision of percutaneous procedures. Ultrasound feedback is preferable for its clinical ease of use, cost and compactness but raises needle detection issues. In this paper, we propose a complete system dedicated to robotized guidance of a flexible needle under 3D ultrasound imaging. This system includes a medical robot dedicated to transperineal needle positioning and insertion, a rapid path planning for needle steering using bevel-tip needle natural curvature in tissue, and an ultrasound-based automatic needle detection algorithm. Since ultrasound-based automatic needle steering is often made difficult by the needle localization in biological tissue, we quantify the benefit of using flexible echogenic needles for robotized guidance under 3D ultrasound. The "echogenic" term refers to the etching of microstructures on the needle shaft. We prove that these structures improve needle visibility and detection robustness in ultrasound images. We finally present promising results when reaching targets using needle steering. The experiments were conducted with various needles in different media (synthetic phantoms and ex vivo biological tissue). For instance, with nitinol needles the mean accuracy is 1.2 mm (respectively 3.8 mm) in phantoms (resp. biological tissue).
Metintas, Muzaffer; Yildirim, Huseyin; Kaya, Tamer; Ak, Guntulu; Dundar, Emine; Ozkan, Ragip; Metintas, Selma
2016-01-01
Image-guided pleural biopsies, both using ultrasound (US) or computed tomography (CT), are important in the diagnosis of pleural disease. However, no consensus exists regarding which biopsy needles are appropriate for specific procedures. In this randomized, prospective study, we aimed to compare CT scan-guided pleural biopsy using an Abrams' needle (CT-ANPB) with US-assisted pleural biopsy using a cutting needle (US-CNPB) with respect to both diagnostic yield and safety. Between February 2009 and April 2013, 150 patients with exudative pleural effusion who could not be diagnosed by cytological analysis were included in the study. The patients were randomized into either the US-CNPB group or the CT-ANPB group. The two groups were compared in terms of diagnostic sensitivity and complications. Of the 150 patients enrolled in this study, 45 were diagnosed with malignant mesothelioma, 46 were diagnosed with metastatic pleural disease, 18 were diagnosed with pleural tuberculosis, 34 were diagnosed with benign pleural disease, and 7 were lost to follow-up. In the US-CNPB group, the diagnostic sensitivity was 66.7%, compared with 82.4% in the CT-ANPB group; the difference between the two groups was statistically significant (p = 0.029). The sensitivity of CT-ANPB increased to 93.7% for patients with a pleural thickness ≥1 cm. The complication rates were low and acceptable. The first diagnostic intervention that should be preferred in patients with pleural effusion and associated pleural thickening on a CT scan is CT-ANPB. US-CNPB should be used primarily in cases for which only pleural thickening but no pleural effusion is noted. © 2016 S. Karger AG, Basel.
Jeon, Yunseok; Choi, Seungpyo; Kim, Heechan
2014-09-01
To investigate whether a novel ultrasound device may be used with a simplified augmented reality technique, and to compare this device with conventional techniques during vascular access using a vascular phantom. Prospective, randomized study. Anesthesiology and Pain Medicine departments of a university-affiliated hospital. 20 physicians with no experience with ultrasound-guided techniques. All participants performed the vascular access technique on the vascular phantom model using both a conventional device and the new ultrasound device. Time and the number of redirections of the needle until aspiration of dye into a vessel of the vascular phantom were measured. The median/interquartile range of time was 39.5/41.7 seconds versus 18.6/10.0 seconds (P < 0.001) and number of redirections was 3/3.5 versus 1/0 (P < 0.001) for the conventional and novel ultrasound devices, respectively. During vascular access in a vascular phantom model, the novel device decreased the time and the number of redirections significantly. The device successfully improved the efficiency of the ultrasound-guided vascular access technique. Copyright © 2014 Elsevier Inc. All rights reserved.
de la Cruz Torres, Blanca; Albornoz Cabello, Manuel; García Bermejo, Paula; Naranjo Orellana, José
2016-08-01
Ultrasound (US)-guided percutaneous needle electrolysis (PNE) is a novel minimally invasive approach, which involves the application of a galvanic current via an acupuncture needle. As in any procedure involving needling, vagal reactions have been reported during PNE. To examine for changes in autonomic activity during the US-guided PNE technique on healthy patellar tendons by measurement and analysis of heart rate variability (HRV). Twenty-two male footballers were randomly allocated to: a control group (11 players), for whom HRV was recorded for 10 min, both at rest and during an exhaustive US examination of the patellar tendon and adjacent structures; and an experimental group (11 players), for whom HRV was recorded for 10 min, both at rest and during application of US-guided PNE on the patellar tendon. The following HRV parameters were assessed: mean NN interval, mean heart rate, time domain parameters (SDNN, rMSSD, pNN50), diameters of the Poincaré plot (SD1, SD2), stress score, and sympathetic/parasympathetic ratio. There were no differences between groups in any baseline measurements, nor were there any significant differences between control group measurements (baseline vs intervention). The experimental group exhibited statistically significant increases in SDNN/SD1 (p=0.02/p=0.03) and SD2 (p=0.03), indicating increased parasympathetic and decreased sympathetic activity, respectively. US-guided PNE was associated with an autonomic imbalance characterised by greater parasympathetic activity, which could potentially result in a vasovagal reaction. Care should be taken to monitor for adverse reactions during US-guided PNE and simple HRV indicators may have a role in early detection. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
[Joint application of 7 interventional pulmonology methods in early diagnosis of lung cancer].
Jin, Fa-Guang; Li, Wang-Ping; Mu, De-Guang; Chu, Dong-Ling; Fu, En-Qing; Xie, Yong-Hong; Lu, Jing-Li; Sun, Ya-Ni
2009-06-23
To evaluate the combination of 7 interventional pulmonology methods in early diagnosis of lung cancer. A total of 467 patients with thoracic and pulmonary lesions (include hilum pulmonis lymphadenectasis, mediastinal lymphadenectasis, pulmonary scobination, lump, lamellar infiltration, small amount of pleural fluid and pleural scobination) had negative results via exfoliative cytology, bacteriology and routine bronchoscopy. All these patients had ultrathin bronchoscopy with biopsy and brushing. For those 155 cases whose foci were located at porta pulmonis, inner zone or median zone, the authors applied ultrathin bronchoscopy with biopsy and brushing guided by X-ray. For those 95 cases whose foci were located at median zone or outer zone and unconnected with chest wall, per cutem lung puncture needle aspiration was employed under the guidance of X-ray. For those 102 cases whose foci were tightly connected with pleural membrane, per cutem lung puncture biopsy was employed under the guidance of type-B ultrasonic. For those 59 cases with suspected central airway foci, auto-fluorescence bronchoscopic biopsy and brushing were employed. For those 67 cases with hilum pulmonis or mediastinal lymphadenectasis, endobronchial ultrasonic transbronchial needle aspiration (EBUS-TBNA) was employed. For those 23 cases with small amount of pleural fluid or pleural scobination, electronic thoracoscopic biopsy and brushing were employed. It was found that 118 cases were diagnosed by ultrathin bronchoscopic biopsy and brushing with a positive rate of 25.3% (118/467), 105 cases by ultrathin bronchoscopy with biopsy and brushing guided by X-ray with a positive rate of 67.7% (105/155), 63 cases by per cutem lung puncture needle aspiration under the guidance of X-ray with a positive rate of 66.3% (63/95), 69 cases by per cutem lung puncture biopsy under the guidance of type-B ultrasound with a positive rate of 67.6% (69/102), 18 cases by auto-fluorescence bronchoscopic biopsy and brushing with a positive rate of 35.3% (18/51), 52 cases by EBUS-TBNA with a positive rate of 77.6% (52/67), 12 cases by electronic thoracoscopic biopsy and brushing with a positive rate of 52.2% (12/23). The total positive diagnostic rate was 93.6% (437/467). And the diagnostic rate of < or = stage II lung cancer (3 cases carcinoma in situ, 84 stage I a, 63 stage Ib, 65 stage IIa and 44 stage IIb) was 82.7% (259/313). Joint application of these 7 interventional bronchoscopic techniques can significantly boost the rate of early diagnosis of lung cancer.
Willard, M D; Weeks, B R; Johnson, M
1999-12-01
Four cats are reported in which cytology smears obtained by ultrasound-guided fine needle aspiration of the liver were interpreted as indicative of hepatic lipidosis. However, histopathology of hepatic tissue samples obtained with Tru-Cut-like needles or wedge biopsy revealed that the cats had inflammatory or neoplastic hepatic disease causing their clinical signs. Fine needle aspiration and cytology may not detect infiltrative lesions, particularly those that are nodular, multifocal, or localised around the portal regions. Fine needle aspirate cytology is a useful diagnostic procedure with many advantages, but care must be taken to avoid diagnosing hepatic lipidosis as the cause of illness when an infiltrative lesion is responsible. Copyright 1999 European Society of Feline Medicine.
Real-time ultrasound-guided PCNL using a novel SonixGPS needle tracking system.
Li, Xiang; Long, Qingzhi; Chen, Xingfa; He, Dalin; Dalin, He; He, Hui
2014-08-01
SonixGPS is a successful ultrasound guidance position system. It helps to improve accuracy in performing complex puncture operations. This study firstly used SonixGPS to perform kidney calyx access in PCNL to investigate its effectiveness and safety. This was a prospectively randomized controlled study performed from September 2011 to October 2012. A total of 97 patients were prospectively randomized into two groups using random number generated from SAS software. 47 Patients were enrolled in conventional ultrasound-guided (US-guided) group and 50 patients were classified into SonixGPS-guided group. Nine patients were lost during follow-up. Hence, a total of 88 patients were qualified and analyzed. Preoperative examinations included urine analysis, urine culture, kidney function, coagulation profile and routine analysis of blood. Ultrasonography was used to evaluate the degree of hydronephrosis. The intraoperative findings, including blood loss, operating time, time to successful puncture, the number of attempts for successful puncture and hospital stay were recorded. The stone clearance rate and complications were analyzed. The present study showed no significant difference between the two groups in terms of demographic data, preoperative markers, stone clearance rate and the stone composition. However, the time to successful puncture, the number of trials for successful puncture, operating time and hospital length of stay were significantly decreased in the SonixGPS-guided group. Furthermore, the hemoglobin decrease was also obviously lower in the SonixGPS group than that in conventional US-guided group. SonixGPS needle tacking system guided PCNL is safe and effective in treating upper urinary tract stones. This novel technology makes puncturing more accuracy and can significantly decrease the incidence of relative hemorrhage and accelerate recovery.
Morse, J; Terrasini, N; Wehbe, M; Philippona, C; Zaouter, C; Cyr, S; Hemmerling, T M
2014-06-01
This study focuses on a recently developed robotic nerve block system and its impact on learning regional anaesthesia skills. We compared success rates, learning curves, performance times, and inter-subject performance variability of robot-assisted vs manual ultrasound (US)-guided nerve block needle guidance. The hypothesis of this study is that robot assistance will result in faster skill acquisition than manual needle guidance. Five co-authors with different experience with nerve blocks and the robotic system performed both manual and robot-assisted, US-guided nerve blocks on two different nerves of a nerve phantom. Ten trials were performed for each of the four procedures. Time taken to move from a shared starting position till the needle was inserted into the target nerve was defined as the performance time. A successful block was defined as the insertion of the needle into the target nerve. Average performance times were compared using analysis of variance. P<0.05 was considered significant. Data presented as mean (standard deviation). All blocks were successful. There were significant differences in performance times between co-authors to perform the manual blocks, either superficial (P=0.001) or profound (P=0.0001); no statistical difference between co-authors was noted for the robot-assisted blocks. Linear regression indicated that the average decrease in time between consecutive trials for robot-assisted blocks of 1.8 (1.6) s was significantly (P=0.007) greater than the decrease for manual blocks of 0.3 (0.3) s. Robot assistance of nerve blocks allows for faster learning of needle guidance over manual positioning and reduces inter-subject performance variability. © The Author [2014]. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Shah, Amit; Best, Alistair J; Rennie, Winston J
2016-06-01
Various therapeutic options are available for treatment of recalcitrant plantar fasciitis. Studies using TOPAZ coblation (ArthroCare, Sunnyvale, CA) have had good early results. The current coblation technique involves a surgical incision or breach of the highly specialized plantar fat pad, which can be associated with risks. We describe a novel technique of ultrasound-guided percutaneous coblation with a lateral heel approach. Advantages include precise targeting of the plantar fascia by direct dynamic visualization of the coblation tip, a true percutaneous approach with a needle skin puncture (<5 mm), and preservation of the plantar fat pad by using a lateral heel approach. © 2016 by the American Institute of Ultrasound in Medicine.
El-Osta, Hazem; Jani, Pushan; Mansour, Ali; Rascoe, Philip; Jafri, Syed
2018-04-23
An accurate assessment of the mediastinal lymph nodes status is essential in the staging and treatment planning of potentially resectable non-small cell lung cancer (NSCLC). We performed this meta-analysis to evaluate the role of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) in detecting occult mediastinal disease in NSCLC with no radiologic mediastinal involvement. The PubMed, Embase, and Cochrane libraries were searched for studies describing the role of EBUS-TBNA in lung cancer patients with radiologically negative mediastinum. The individual and pooled sensitivity, prevalence, negative predictive value (NPV), and diagnostic odds ratio (DOR) were calculated using the random effects model. Metaregression analysis, heterogeneity, and publication bias were also assessed. A total of 13 studies that met the inclusion criteria were included in the meta-analysis. The pooled effect size of the different diagnostic parameters were estimated as follows: prevalence, 12.8% (95% CI, 10.4%-15.7%); sensitivity, 49.5% (95% confidence interval [CI], 36.4%-62.6%); NPV, 93.0% (95% CI, 90.3%-95.0%); and log DOR, 5.069 (95% CI, 4.212-5.925). Significant heterogeneity was noticeable for the sensitivity, disease prevalence, and NPV, but not observed for log DOR. Publication bias was detected for sensitivity, NPV and log DOR but not for prevalence. Bivariate meta-regression analysis showed no significant association between the pooled calculated parameters and the type of anesthesia, imaging utilized to define negative mediastinum, rapid on-site test usage, and presence of bias by QUADAS-2 tool. Interestingly, we observed a greater sensitivity, NPV and log DOR for studies published prior to 2010, and for prospective multicenter studies. Among NSCLC patients with a radiologically normal mediastinum, the prevalence of mediastinal disease is 12.8% and the sensitivity of EBUS-TBNA is 49.5%. Despite the low sensitivity, the resulting NPV of 93.0% for EBUS-TBNA suggests that mediastinal metastasis is uncommon in such patients.
Matsuyama, Masato; Ishii, Hiroshi; Kuraoka, Kensuke; Yukisawa, Seigo; Kasuga, Akiyoshi; Ozaka, Masato; Suzuki, Sho; Takano, Kouichi; Sugiyama, Yuko; Itoi, Takao
2013-01-01
AIM: To clarify the effectiveness and safety of endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) for the diagnosis of pancreatic cancer (PC). METHODS: Patients who were diagnosed with unresectable, locally advanced or metastatic PC between February 2006 and September 2011 were selected for this retrospective study. FNA biopsy for pancreatic tumors had been performed percutaneously under extracorporeal ultrasound guidance until October 2009; then, beginning in November 2009, EUS-FNA has been performed. We reviewed the complete medical records of all patients who met the selection criteria for the following data: sex, age, location and size of the targeted tumor, histological and/or cytological findings, details of puncture procedures, time from day of puncture until day of definitive diagnosis, and details of severe adverse events. RESULTS: Of the 121 patients who met the selection criteria, 46 had a percutaneous biopsy (Group A) and 75 had an EUS-FNA biopsy (Group B). Adequate cytological specimens were obtained in 42 Group A patients (91.3%) and all 75 Group B patients (P = 0.0192), and histological specimens were obtained in 41 Group A patients (89.1%) and 65 Group B patients (86.7%). Diagnosis of malignancy by cytology was positive in 33 Group A patients (78.6%) and 72 Group B patients (94.6%) (P = 0.0079). Malignancy by both cytology and pathology was found in 43 Group A (93.5%) and 73 Group B (97.3%) patients. The mean period from the puncture until the cytological diagnosis in Group B was 1.7 d, which was significantly shorter than that in Group A (4.1 d) (P < 0.0001). Severe adverse events were experienced in two Group A patients (4.3%) and in one Group B patient (1.3%). CONCLUSION: EUS-FNA, as well as percutaneous needle aspiration, is an effective modality to obtain cytopathological confirmation in patients with advanced PC. PMID:23613631
Zhang, Catherine D; Erickson, Dana; Levy, Michael J; Gleeson, Ferga C; Salomao, Diva R; Delivanis, Danae A; Bancos, Irina
2017-12-01
While the left adrenal gland is readily accessible via endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA), data regarding the utility of EUS-FNA in the diagnosis of adrenal lesions remain limited. We aimed to ( 1) describe the clinical context, adverse event rate, and diagnostic performance of EUS-FNA, and ( 2) compare the safety profile and diagnostic accuracy of EUS-FNA with percutaneous adrenal biopsy. Single-center, retrospective cohort study. Medical records of patients who underwent adrenal EUS-FNA from 2005-2016 were reviewed. Biopsy outcomes were evaluated using a predefined reference standard. Results were compared to patients who underwent percutaneous biopsy (n = 419; 1994-2014) at the same institution. A total of 121 patients underwent EUS-FNA of 122 adrenal lesions (left [n = 121]; right [n = 1]; mean lesion size, 1.8 cm). Cytology was positive for malignancy in 35 (29%), suspicious for malignancy in 1 (1%), atypical in 1 (1%), negative for malignancy in 81 (66%), and nondiagnostic in 4 (3%). No adverse events were reported. EUS-FNA diagnosed metastasis with a sensitivity of 100%, specificity of 97.4%, positive predictive value of 91.7%, and negative predictive value of 100%. When compared to percutaneous biopsy, lesion size (1.8 cm vs. 3.7 cm; P<.001) and biopsy site (99% vs. 62% left adrenal; P<.001) were significantly different. EUS-FNA adverse event rate was lower than percutaneous biopsy (0% vs. 4%; P = .024), but nondiagnostic rates were similar (3.3% vs. 4.8%; P = .48). EUS-FNA is a sensitive technique to sample adrenal lesions in patients at high risk for adrenal metastasis with fewer adverse events compared to percutaneous biopsy. CI = confidence interval CT = computed tomography EUS-FNA = endoscopic ultrasound-guided fine-needle aspiration NPV = negative predictive value PPV = positive predictive value TUS = transabdominal ultra-sound.
Choudhary, Narendra S; Puri, Rajesh; Saigal, Sanjiv; Bhangui, Prashant; Saraf, Neeraj; Shah, Vinit; Nasa, Mukesh; Sarin, Haimanti; Guleria, Mridula; Sud, Randhir; Soin, Arvinder S
2016-11-01
Diagnosis of metastatic disease is important in patients with cirrhosis and hepatocellular carcinoma (HCC) to prevent futile liver transplantation. Some of these patients have metastatic lymphadenopathy; however, it is difficult to perform percutaneous fine-needle aspiration due to presence of collateral and anatomic location. Endoscopic ultrasound (EUS)-guided fine-needle aspiration (FNA) of lymph nodes offers several advantages like real-time vision, proximity to target, and avoidance of collaterals. The aim of this study was to look for metastatic lymphadenopathy by EUS-guided FNA (EUS-FNA) in prospective liver transplant recipients with HCC. A prospective study was conducted from January 2013 to January 2016 at a tertiary care center. All prospective liver transplant recipients with HCC had PET-CT and bone scan to look for metastatic disease. EUS-FNA was done in patients with abdominal or mediastinal lymphadenopathy and no evidence of extrahepatic disease. Data is shown as median (25-75 interquartile range). EUS-guided FNA was done for 50 patients (42 abdominal and 8 mediastinal lymph nodes), age 57 (53-62) years, Child-Turcotte-Pugh 7 (6-9), and model for end-stage liver disease 10 (7-16). FNA material was adequate in 92% patients, metastasis in 15 (30%), granulomatous lymphadenopathy in 4 (8%), and reactive change in 27 patients (54%). The material was inadequate for diagnosis in 4 (8%) patients. Thus, EUS-guided FNA precluded transplantation in 30% of patients with lymphadenopathy, and 4 (8%) patients received anti-tubercular therapy before liver transplantation. In patients with HCC and lymphadenopathy, EUS-guided FNA detected metastatic disease and precluded liver transplantation in approximately one third of patients.
Cirla, A.; Rondena, M.; Bertolini, G.
2016-01-01
The purpose of this study was to evaluate the diagnostic value of imaging-guided core needle biopsy for canine orbital mass diagnosis. A second excisional biopsy obtained during surgery or necropsy was used as the reference standard. A prospective feasibility study was conducted in 23 canine orbital masses at a single centre. A complete ophthalmic examination was always followed by orbital ultrasound and computed tomography (CT) examination of the head. All masses were sampled with the patient still on the CT table using ultrasound (US) guided automatic tru-cut device. The most suitable sampling approach to the orbit was chosen each time based on the CT image analysis. One of the following different approaches was used: trans-orbital, trans-conjunctival or trans-masseteric. In all cases, the imaging-guided biopsy provided a sufficient amount of tissue for the histopathological diagnosis, which concurred with the biopsies obtained using the excisional technique. CT examination was essential for morphological diagnosis and provided detailed topographic information that allowed us to choose the safest orbital approach for the biopsy. US guided automatic tru-cut biopsy based on CT images, performed with patient still on the CT table, resulted in a minimally invasive, relatively easy, and accurate diagnostic procedure in dogs with orbital masses. PMID:27540512
Cirla, A; Rondena, M; Bertolini, G
2016-01-01
The purpose of this study was to evaluate the diagnostic value of imaging-guided core needle biopsy for canine orbital mass diagnosis. A second excisional biopsy obtained during surgery or necropsy was used as the reference standard. A prospective feasibility study was conducted in 23 canine orbital masses at a single centre. A complete ophthalmic examination was always followed by orbital ultrasound and computed tomography (CT) examination of the head. All masses were sampled with the patient still on the CT table using ultrasound (US) guided automatic tru-cut device. The most suitable sampling approach to the orbit was chosen each time based on the CT image analysis. One of the following different approaches was used: trans-orbital, trans-conjunctival or trans-masseteric. In all cases, the imaging-guided biopsy provided a sufficient amount of tissue for the histopathological diagnosis, which concurred with the biopsies obtained using the excisional technique. CT examination was essential for morphological diagnosis and provided detailed topographic information that allowed us to choose the safest orbital approach for the biopsy. US guided automatic tru-cut biopsy based on CT images, performed with patient still on the CT table, resulted in a minimally invasive, relatively easy, and accurate diagnostic procedure in dogs with orbital masses.
Giuliani, Michela; Rinaldi, Pierluigi; Rella, Rossella; Fabrizi, Gina; Petta, Federica; Carlino, Giorgio; Di Leone, Alba; Mulè, Antonino; Bufi, Enida; Romani, Maurizio; Belli, Paolo; Bonomo, Lorenzo
2017-11-01
The aim of the present study was to assess the diagnostic accuracy of ultrasound-guided core needle biopsy (US-CNB) of breast lesions, comparing smaller needles (16- and 18-gauge) with the 14-gauge needle, and to analyze the lesion characteristics influencing US-CNB diagnostic performance. All the patients provided informed consent before the biopsy procedure. The data from breast lesions that had undergone US-CNB in our institution from January 2011 to January 2015 were retrospectively reviewed. The inclusion criterion was the surgical histopathologic examination findings of the entire lesion or radiologic follow-up data for ≥ 24 months. The exclusion criterion was the use of preoperative neoadjuvant therapy. The US-CNB results were compared with the surgical pathologic results or with the follow-up findings in the 3 needle size groups (14-, 16-, and 18-gauge). The needle size- and lesion characteristic-specific diagnostic accuracy parameters were evaluated. Statistical analysis was performed using a dedicated software program, and P ≤ .01 was considered significant. A total of 1118 US-CNB cases (1042 patients) were included. Of the 1118 cases, 630 (56.3%) were in the 14-gauge group, 136 (12.2%) in the 16-gauge, and 352 (31.5%) in the 18-gauge needle group. Surgery was performed on 800 lesions (71.6%). Of these, 619 were malignant, 77 were high risk, and 104 were benign. The remaining 318 lesions (28.4%) underwent follow-up imaging studies. All the lesions were stable and, therefore, were considered benign. No differences were observed in the diagnostic accuracy parameters among the 3 needle size groups (P > .01). The false-negative rate was greater for lesions < 10 mm (7.2%) (P < .01) but without statistically significant differences among the 3 gauges (P > .01). US-CNB performed with small needles (16 and 18 gauge) had the same diagnostic accuracy as that performed with 14-gauge needles, regardless of the lesion characteristics. Copyright © 2017 Elsevier Inc. All rights reserved.
Robotic Assistance for Ultrasound-Guided Prostate Brachytherapy
Fichtinger, Gabor; Fiene, Jonathan P.; Kennedy, Christopher W.; Kronreif, Gernot; Iordachita, Iulian; Song, Danny Y.; Burdette, Everette C.; Kazanzides, Peter
2016-01-01
We present a robotically assisted prostate brachytherapy system and test results in training phantoms and Phase-I clinical trials. The system consists of a transrectal ultrasound (TRUS) and a spatially co-registered robot, fully integrated with an FDA-approved commercial treatment planning system. The salient feature of the system is a small parallel robot affixed to the mounting posts of the template. The robot replaces the template interchangeably, using the same coordinate system. Established clinical hardware, workflow and calibration remain intact. In all phantom experiments, we recorded the first insertion attempt without adjustment. All clinically relevant locations in the prostate were reached. Non-parallel needle trajectories were achieved. The pre-insertion transverse and rotational errors (measured with a Polaris optical tracker relative to the template’s coordinate frame) were 0.25mm (STD=0.17mm) and 0.75° (STD=0.37°). In phantoms, needle tip placement errors measured in TRUS were 1.04mm (STD=0.50mm). A Phase-I clinical feasibility and safety trial has been successfully completed with the system. We encountered needle tip positioning errors of a magnitude greater than 4mm in only 2 out of 179 robotically guided needles, in contrast to manual template guidance where errors of this magnitude are much more common. Further clinical trials are necessary to determine whether the apparent benefits of the robotic assistant will lead to improvements in clinical efficacy and outcomes. PMID:18650122
Relea, A; Alonso, J A; González, M; Zornoza, C; Bahamonde, S; Viñuela, B E; Encinas, M B
2018-06-12
To determine whether the twinkling artifact on Doppler ultrasound imaging corresponds to microcalcifications previously seen on mammograms and to evaluate the usefulness of this finding in the ultrasound management of suspicious microcalcifications. We used ultrasonography to prospectively examine 46 consecutive patients with groups of microcalcifications suspicious for malignancy identified at mammography, searching for the presence of the twinkling artifact to identify the microcalcifications. Once we identified the microcalcifications, we obtained core-needle biopsy specimens with 11G needles and then used X-rays to check the specimens for the presence of microcalcifications. We analyzed the percentage of detection and obtainment of microcalcifications by core-needle biopsy with this technique and the radiopathologic correlation. Microcalcifications that were not detected by ultrasound or discordant lesions were biopsied by stereotaxy at another center. We also used ultrasound guidance for preoperative marking with clips, usually orienting them radially. We identified and biopsied 41 of the 46 lesions under ultrasound guidance, including 24 of 25 carcinomas (17 in situ). B-mode ultrasound was sufficient for biopsying the microcalcifications in 14 patients, although the presence of the twinkling artifact increased the number of microcalcifications detected and thus enabled more accurate preoperative marking. Thanks to the twinkling sign, we were able to identify 27 additional groups of microcalcifications (89% vs. 30%; p < 0.05). All the surgical specimens had margins free of disease. The twinkling artifact is useful for microcalcifications in ultrasound examinations, enabling a significant increase in the yield of ultrasound-guided biopsies and better preoperative marking of groups of microcalcifications. Copyright © 2018 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.
Jeong, Seok Hoo; Yoon, Hyun Hwa; Kim, Eui Joo; Kim, Yoon Jae; Kim, Yeon Suk; Cho, Jae Hee
2017-01-01
Abstract Endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) is the accurate diagnostic method for pancreatic masses and its accuracy is affected by various FNA methods and EUS equipment. Therefore, we aimed to elucidate the instrumental and methodologic factors for determining the diagnostic yield of EUS-FNA for pancreatic solid masses without an on-site cytopathology evaluation. We retrospectively reviewed the medical records of 260 patients (265 pancreatic solid masses) who underwent EUS-FNA. We compared historical conventional EUS groups with high-resolution imaging devices and finally analyzed various factors affecting EUS-FNA accuracy. In total, 265 pancreatic solid masses of 260 patients were included in this study. The accuracy, sensitivity, specificity, positive predictive value, and negative predictive value of EUS-FNA for pancreatic solid masses without on-site cytopathology evaluation were 83.4%, 81.8%, 100.0%, 100.0%, and 34.3%, respectively. In comparison with conventional image group, high-resolution image group showed the increased accuracy, sensitivity and specificity of EUS-FNA (71.3% vs 92.7%, 68.9% vs 91.9%, and 100% vs 100%, respectively). On the multivariate analysis with various instrumental and methodologic factors, high-resolution imaging (P = 0.040, odds ratio = 3.28) and 3 or more needle passes (P = 0.039, odds ratio = 2.41) were important factors affecting diagnostic yield of pancreatic solid masses. High-resolution imaging and 3 or more passes were the most significant factors influencing diagnostic yield of EUS-FNA in patients with pancreatic solid masses without an on-site cytopathologist. PMID:28079803
Autonomous surgical robotics using 3-D ultrasound guidance: feasibility study.
Whitman, John; Fronheiser, Matthew P; Ivancevich, Nikolas M; Smith, Stephen W
2007-10-01
The goal of this study was to test the feasibility of using a real-time 3D (RT3D) ultrasound scanner with a transthoracic matrix array transducer probe to guide an autonomous surgical robot. Employing a fiducial alignment mark on the transducer to orient the robot's frame of reference and using simple thresholding algorithms to segment the 3D images, we tested the accuracy of using the scanner to automatically direct a robot arm that touched two needle tips together within a water tank. RMS measurement error was 3.8% or 1.58 mm for an average path length of 41 mm. Using these same techniques, the autonomous robot also performed simulated needle biopsies of a cyst-like lesion in a tissue phantom. This feasibility study shows the potential for 3D ultrasound guidance of an autonomous surgical robot for simple interventional tasks, including lesion biopsy and foreign body removal.
Nayak, Anupma; Carkaci, Selin; Gilcrease, Michael Z.; Liu, Ping; Middleton, Lavinia P.; Bassett, Roland L.; Zhang, Jinxia; Zhang, Hong; Coyne, Robin L.; Bevers, Therese B.; Sneige, Nour; Huo, Lei
2015-01-01
The management of benign papilloma (BP) without atypia identified on breast core needle biopsy (CNB) is controversial. We describe the clinicopathologic features of 80 patients with such lesions in our institution, with an upgrade rate to malignancy of 3.8%. A multidisciplinary approach to select patients for surgical excision is recommended. Background The management of benign papilloma (BP) without atypia identified on breast core needle biopsy (CNB) is controversial. In this study, we determined the upgrade rate to malignancy for BPs without atypia diagnosed on CNB and whether there are factors associated with upgrade. Methods Through our pathology database search, we studied 80 BPs without atypia identified on CNB from 80 patients from 1997 to 2010, including 30 lesions that had undergone excision and 50 lesions that had undergone ≥ 2 years of radiologic follow-up. Associations between surgery or upgrade to malignancy and clinical, radiologic, and pathologic features were analyzed. Results Mass lesions, lesions sampled by ultrasound-guided CNB, and palpable lesions were associated with surgical excision. All 3 upgraded cases were mass lesions sampled by ultrasound-guided CNB. None of the lesions with radiologic follow-up only were upgraded to malignancy. The overall upgrade rate was 3.8%. None of the clinical, radiologic, or histologic features were predictive of upgrade. Conclusion Because the majority of patients can be safely managed with radiologic surveillance, a selective approach for surgical excision is recommended. Our proposed criteria for excision include pathologic/radiologic discordance or sampling by ultrasound-guided CNB without vacuum assistance when the patient is symptomatic or lesion size is ≥ 1.5 cm. PMID:24119786
Robotic Needle Guide for Prostate Brachytherapy: Clinical Testing of Feasibility and Performance
Song, Danny Y; Burdette, Everette C; Fiene, Jonathan; Armour, Elwood; Kronreif, Gernot; Deguet, Anton; Zhang, Zhe; Iordachita, Iulian; Fichtinger, Gabor; Kazanzides, Peter
2010-01-01
Purpose Optimization of prostate brachytherapy is constrained by tissue deflection of needles and fixed spacing of template holes. We developed and clinically tested a robotic guide towards the goal of allowing greater freedom of needle placement. Methods and Materials The robot consists of a small tubular needle guide attached to a robotically controlled arm. The apparatus is mounted and calibrated to operate in the same coordinate frame as a standard template. Translation in x and y directions over the perineum ±40mm are possible. Needle insertion is performed manually. Results Five patients were treated in an IRB-approved study. Confirmatory measurements of robotic movements for initial 3 patients using infrared tracking showed mean error of 0.489 mm (SD 0.328 mm). Fine adjustments in needle positioning were possible when tissue deflection was encountered; adjustments were performed in 54/179 (30.2%) needles placed, with 36/179 (20.1%) adjustments of > 2mm. Twenty-seven insertions were intentionally altered to positions between the standard template grid to improve the dosimetric plan or avoid structures such as pubic bone and blood vessels. Conclusions Robotic needle positioning provided a means of compensating for needle deflections as well as the ability to intentionally place needles into areas between the standard template holes. To our knowledge, these results represent the first clinical testing of such a system. Future work will be incorporation of direct control of the robot by the physician, adding software algorithms to help avoid robot collisions with the ultrasound, and testing the angulation capability in the clinical setting. PMID:20729152
Goldberg, Robert; Colt, Henri G; Davoudi, Mohsen; Cherrison, Larry
2009-09-01
Transbronchial needle aspiration (TBNA) is used to sample mediastinal abnormalities and lymph node stations for diagnostic purposes and lung cancer staging. The procedure is underused, operator dependent, and reputed to have a steep learning curve. Other difficulties arise from a bronchoscopist's failure to insert the needle satisfactorily into the target node. The purpose of this study was to evaluate the realism and helpfulness of a lo-fidelity, easily constructed hybrid model used for learning and practicing TBNA. The model is constructed by attaching a porcine tracheobronchial tree to a Laerdal Airway Model mounted on polyvinyl chloride (PVC) piping. Twelve individuals with various levels of bronchoscopy training and experience were given a 15-min introductory PowerPoint presentation on TBNA strategy and planning, execution, and response to complications. Participants then practiced TBNA alone and with guidance, aided by an assistant, as many times as individually necessary to feel comfortable with the procedure. A five-point Likert scale 8-item questionnaire was then completed. Participants were unanimously positive about their experience (mean scores 4.25-4.91). The model was realistic, provided increased comfort with TBNA techniques, and allowed practice of communication skills. This realistic, affordable, and easily constructed hybrid lo-fidelity airway model allows beginner and experienced bronchoscopists opportunities to learn and practice basic TBNA techniques and team communication skills without placing patients at risk.
Biopsy of Liver Target Lesions under Contrast-Enhanced Ultrasound Guidance - A Multi-Center Study.
Francica, Giampiero; Meloni, Maria Franca; de Sio, Ilario; Terracciano, Fulvia; Caturelli, Eugenio; Riccardi, Laura; Roselli, Paola; Iadevaia, Maddalena Diana; Scaglione, Mariano; Lenna, Giovanni; Chiang, Jason; Pompili, Maurizio
2017-12-12
Purpose To retrospectively characterize the prevalence and impact of contrast-enhanced ultrasound (CEUS) as a guidance technique for the biopsy of liver target lesions (LTLs) at six interventional ultrasound centers. Materials and Methods The six participating centers retrospectively selected all patients in whom biopsy needles were positioned in LTLs during CEUS. The prevalence of CEUS-guided biopsies at each center between 2005 and 2016, contrast agent consumption, procedure indications, diagnostic yield and complications were assessed. Informed consent was obtained for all patients. Results CEUS-guided biopsy of LTLs was carried out in 103 patients (68 M/35 F, median age: 69 yrs) with 103 liver target lesions (median size: 20 mm) using cutting needles (18 - 20 g) in 94 cases (91.2 %). CEUS-guided biopsy represented 2.6 % (range: 0.8 - 7.7 %) of 3818 biopsies on LTLs carried out at the participating centers. Indications to CEUS-guided biopsy were: a target lesion not visible on non-enhanced US (27.2 %), improvement of conspicuity of the target (33 %), choice of non-necrotic area inside the target (39.8 %). 26 patients (25.2 %) had a previously non-diagnostic cyto-histological exam. The diagnostic accuracy of the technique was 99 %. No major complications followed infusion of contrast agent or biopsy performance. Conclusion The indications for CEUS-guided biopsy for LTLs are limited, but CEUS can be useful in challenging clinical scenarios, e. g. poorly visualized or invisible lesions or sampling of non-necrotic areas in the target lesions. There is also a potential advantage in using CEUS to guide repeat biopsies after unsuccessful sampling performed using the standard ultrasound technique. © Georg Thieme Verlag KG Stuttgart · New York.
Sampson, Steven; Meng, Michael; Schulte, Adam; Trainor, Drew; Montenegro, Roberto; Aufiero, Danielle
2011-02-01
Dupuytren contracture is a debilitating disease that characteristically presents as a firm nodularity on the palmar surface of the hand with coalescing cords of soft tissue on the webs and digits. With few nonsurgical modalities providing clinical benefits, open surgical procedures are the standard of care for patients with this condition. However, recent studies have associated surgical intervention with many complications, necessitating further exploration of nonsurgical treatment options. We describe the case of a 64-year-old woman who presented with decreased extension of the fourth and fifth digits on the upper extremities bilaterally; previous conservative treatment regimens had been unsuccessful. After a diagnostic ultrasound, the patient was diagnosed as having Dupuytren contracture and underwent 5 treatments consisting of ultrasound-guided dry-needle aponeurotomy, lidocaine injections, and osteopathic manipulative treatment. During the fifth treatment session, the patient experienced dramatic relief of her symptoms after a palpable release during the manual manipulation portion of her therapeutic regimen. At 2-week follow-up, the patient was symptom-free. Based on this desirable outcome, the authors suggest future research be directed at minimally invasive therapeutic options in the management of Dupuytren contracture.
Voss, M; Hammel, P; Molas, G; Palazzo, L; Dancour, A; O'Toole, D; Terris, B; Degott, C; Bernades, P; Ruszniewski, P
2000-01-01
AIM—To assess the feasibility and diagnostic accuracy of endoscopic ultrasound guided fine needle biopsy (EUS-FNAB) in patients with solid pancreatic masses. METHODS—Ninety nine consecutive patients with pancreatic masses were studied. Histological findings obtained by EUS-FNAB were compared with the final diagnosis assessed by surgery, biopsy of other tumour site or at postmortem examination, or by using a combination of clinical course, imaging features, and tumour markers. RESULTS—EUS-FNAB was feasible in 90 patients (adenocarcinomas, n = 59; neuroendocrine tumours, n = 15; various neoplasms, n = 6; pancreatitis, n = 10), and analysable material was obtained in 73. Tumour size (⩾ or < 25 mm in diameter) did not influence the ability to obtain informative biopsy samples. Diagnostic accuracy was 74.4% (adenocarcinomas, 81.4%; neuroendocrine tumours, 46.7%; other lesions, 75%; p<0.02). Overall, the diagnostic yield in all 99 patients was 68%. Successful biopsies were performed in six patients with portal hypertension. Minor complications (moderate bleeding or pain) occurred in 5% of cases. CONCLUSIONS—EUS-FNAB is a useful and safe method for the investigation of pancreatic masses, with a high feasibility rate even when lesions are small. Overall diagnostic accuracy of EUS-FNAB seems to depend on the tumour type. Keywords: pancreas; tumour; endoscopic ultrasound; fine needle aspiration biopsy PMID:10644320
Ultrasound guided electrochemotherapy for the treatment of a clear cell thymoma in a cat
Spugnini, Enrico Pierluigi; Menicagli, Francesco; Pettorali, Michela; Baldi, Alfonso
2017-01-01
A twelve-year-old male castrated domestic shorthair cat was presented for rapidly progressing respiratory distress. The cat was depressed, tachypneic and moderately responsive. Ultrasonography showed a mediastinal mass associated with a significant pleural effusion that needed tapping every five to seven days. Ultrasound guided biopsy yielded a diagnosis of clear cell thymoma upon histopathology. After complete staging procedures, the owner elected to treat the cat with electrochemotherapy (ECT) using systemic bleomycin. Two sessions of ultrasound guided ECT were performed at two week intervals with trains of biphasic electric pulses applied using needle electrodes until complete coverage of the area was achieved. The treatment was well tolerated and resulted in partial remission (PR). Additional sessions were performed on a monthly basis. The cat is still in PR after fourteen months. ECT resulted in improved local control and should be considered among the available adjuvant treatments in pets carrying visceral tumors. PMID:28331834
Okuwaki, Kosuke; Kida, Mitsuhiro; Masutani, Hironori; Yamauchi, Hiroshi; Katagiri, Hiroyuki; Mikami, Tetuo; Miyazawa, Shiro; Iwai, Tomohisa; Takezawa, Miyoko; Imaizumi, Hiroshi; Koizumi, Wasaburo
2013-01-01
Primary perivascular epithelioid cell tumors (PEComas) of the pancreas are extremely rare. We herein report our experience with a patient who had a primary PEComa of the pancreas that was diagnosed by the preoperative histopathological examination of a biopsy specimen obtained by endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA). The patient was a 43-year-old woman whose chief complaint was abdominal pain. Imaging studies revealed a pancreatic tumor. Gastrointestinal stromal tumor (GIST), solid pseudopapillary tumor and neuroendocrine tumor were considered in the differential diagnosis. A histopathological examination of a specimen of the tumor obtained using EUS-FNA showed spindle-shaped tumor cells with enlarged nuclei and eosinophilic cytoplasm. The tumor cells proliferated in a sheet-like fashion and stained positive for the melanoma-associated antigen HMB-45. A PEComa was thus diagnosed. If an adequate tumor specimen can be obtained using EUS-FNA, immunostaining may facilitate the diagnosis of extremely rare diseases and therefore assist in deciding the treatment policy.
Daswani, Ravi; Singla, Vikas; Arora, Anil; Sharma, Praveen; Bansal, Naresh; Kumar, Ashish
2017-01-01
The gold standard for diagnosis of peritoneal tuberculosis is growth of Mycobacterium tuberculosis on ascitic fluid or peritoneal culture. Due to the nonspecific signs and symptoms of disease, its early diagnosis is difficult, especially in patients with decompensated cirrhosis. The reported sensitivity of ascitic fluid is low, and to obtain tissue for peritoneal biopsy in patients with cirrhosis is difficult. Thus, there is an urgent need to explore newer diagnostic modalities, especially those that can provide perioneal tissue by less invasive means. Endoscopic ultrasound (EUS)-guided fine needle aspiration (FNA) is a good alternative to obtain peritoneal tissue for establishing the diagnosis of peritoneal tuberculosis (TB). We hereby report the use of EUS- FNA of the peritoneum in five patients with decompensated cirrhosis, in whom the diagnosis could not be confirmed by other means; thus, we propose EUS-FNA of the peritoneum as a new, safe, and unexplored technique for diagnosis of peritoneal TB.
Igarashi, Ryo; Irisawa, Atsushi; Shibukawa, Goro; Yamabe, Akane; Fujisawa, Mariko; Sato, Ai; Maki, Takumi; Arakawa, Noriyuki; Yoshida, Yoshitsugu; Yamamoto, Shogo; Ikeda, Tsunehiko
2016-10-01
Eosinophilic esophagitis (EoE) is diagnosed by microscopic findings of eosinophilic infiltration into the squamous epithelium. In contrast, another disease concept termed "eosinophilic esophageal myositis (EoEM)" has been proposed, whereby there is eosinophilic infiltration into the muscularis propria instead. A 60-year-old man was referred to our hospital for chest pain, dysphagia, and several episodes of esophageal food impaction. Although EoE was suspected based on clinical features, biopsy specimens showed no mucosal eosinophilic infiltration. Endoscopic ultrasound (EUS) showed thickening of the muscularis propria layer and subsequent EUS-guided fine-needle aspiration biopsy (EUS-FNA) revealed eosinophilic infiltration into the muscularis propria. Although the patient's symptoms gradually improved after steroid administration, complete remission was not achieved after 1 year of treatment. This case may reflect a disorder distinct from typical EoE based on eosinophilic infiltration of the muscularis propria but not the squamous epithelium, and we, therefore, diagnosed it as EoEM using the EUS-FNA findings as reference.
Okasha, Hussein Hassan; Ashry, Mahmoud; Imam, Hala M. K.; Ezzat, Reem; Naguib, Mohamed; Farag, Ali H.; Gemeie, Emad H.; Khattab, Hani M.
2015-01-01
Background and Objective: The addition of fine-needle aspiration (FNA) to different imaging modalities has raised the accuracy for diagnosis of cystic pancreatic lesions. We aim to differentiate benign from neoplastic pancreatic cysts by evaluating cyst fluid carcinoembryonic antigen (CEA), carbohydrate antigen (CA19-9), and amylase levels and cytopathological examination, including mucin stain. Patients and Methods: This prospective study included 77 patients with pancreatic cystic lesions. Ultrasound-FNA (US-FNA) or endoscopic ultrasound-FNA (EUS-FNA) was done according to the accessibility of the lesion. The aspirated specimens were subjected to cytopathological examination (including mucin staining), tumor markers (CEA, CA19-9), and amylase level. Results: Cyst CEA value of 279 or more showed high statistical significance in differentiating mucinous from nonmucinous lesions with sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of 73%, 60%, 50%, 80%, and 65%, respectively. Cyst amylase could differentiate between neoplastic and nonneoplastic cysts at a level of 1043 with sensitivity of 58%, specificity of 75%, PPV of 73%, NPV of 60%, and accuracy of 66%. CA19-9 could not differentiate between neoplastic and nonneoplastic cysts. Mucin examination showed a sensitivity of 85%, specificity of 95%, PPV of 92%, NPV of 91%, and accuracy of 91% in differentiating mucinous from non-mucinous lesions. Cytopathological examination showed a sensitivity of 81%, specificity of 94%, PPV of 94%, NPV of 83%, and accuracy of 88%. Conclusion: US or EUS-FNA with analysis of cyst CEA level, CA19-9, amylase, mucin stain, and cytopathological examination increases the diagnostic accuracy of cystic pancreatic lesions. PMID:26020048
Acupuncture sensation during ultrasound guided acupuncture needling
Park, Jongbae J.; Akazawa, Margeaux; Ahn, Jaeki; Beckman-Harned, Selena; Lin, Feng-Chang; Lee, Kwangjae; Fine, Jason; Davis, Robert T; Langevin, Helene
2014-01-01
Background Although acupuncture sensation (also known as de qi) is a cornerstone of traditional acupuncture therapy, most research has accepted the traditional method of defining acupuncture sensation only through subjective patient reports rather than on any quantifiable physiological basis. Purpose To preliminarily investigate the frequency of key sensations experienced while needling to specific, quantifiable tissue levels (TLs) guided by ultrasound (US) imaging. Methods Five participants received needling at two acupuncture points and two control points at four TLs. US scans were used to determine when each TL was reached. Each volunteer completed 32 sets of modified Southampton Needle Sensation Questionnaires. Part one of the study tested sensations experienced at each TL and part two compared the effect of oscillation alone versus oscillation + rotation. Results In all volunteers, the frequency of pricking, sharp sensations was significantly greater in shallower TLs than deeper (p=0.007); the frequency of sensations described as deep, dull and heavy, as spreading, and as electric shocks was significantly greater in deeper TLs than shallower (p=0.002). Sensations experienced did not significantly differ between real and control points within each of three TLs (p>0.05) except TL 4 (p=0.006). The introduction of needle rotation significantly increased deep, dull, heavy sensations, but not pricking and sharp sensations; within each level, the spectrum of sensation experienced during both oscillation + rotation and oscillation alone did not significantly differ between acupuncture and control points. Conclusion The preliminary study indicates a strong connection between acupuncture sensation and both tissue depth and needle rotation. Furthermore, the new methodology has been proven feasible. A further study with an objective measurement is warranted. PMID:21642648
Needle biopsy for hepatic vitamin A levels in lions (Panthera leo).
Shamir, Merav H; Rubin, Gal; Aizenberg, Zachi; Berkovich, Zipi; Reifen, Ram; Horowitz, Igal; Bdolah-Abram, Tali; Aroch, Itamar
2012-06-01
Hypovitaminosis A (HA)-related skull malformations resulting in neurologic abnormalities and death have been, and still are, reported in captive lions (Panthera leo) worldwide. Liver vitamin A (VA) concentration is the most reliable indicator of animals' VA status, and its assessment is essential in prevention and treatment of HA in lions. A percutaneous needle liver biopsy using high-performance liquid chromatography ultraviolet retinoid analysis for VA concentration measurement was validated. It was first assessed in vitro using chicken liver. Later, the safety and feasibility of ultrasound-guided percutaneous needle liver biopsy was assessed in living lions. Hepatic VA concentrations in lion liver were measured using the above laboratory method. Mean chicken hepatic VA concentration in needle biopsy (NB) and wedge biopsy (WB) of the same liver lobes were 108.66 and 60.89 microg/g wet tissue, respectively, and were significantly (P = 0.03) correlated (r = 0.74). The calculated linear regression for predicting VA concentration in WB using NB VA for chicken liver was 25.194 + 0.3234x NB (microg/g). Four ultrasound-guided percutaneous needle liver biopsies were obtained from each of the four lions under general anesthesia. Mean hepatic VA concentration was 8.25 microg/g wet tissue (range 1.43-25.29 microg/g). Mean serum VA concentration, measured in these four lions was 1,011.1 nmol/L with a standard deviation of 337.91 nmol/L (range 590.26-1,077.2 nmol/L). The lions recovered uneventfully, and no complications were observed during a 4-yr follow-up period. In conclusion, the percutaneous needle liver biopsy technique is a reliable, practical, safe tool for obtaining liver tissue samples antemortem for assessment of the VA status in lions and can be used in future studies.
Dong, Guo-Chung; Chiu, Li-Chen; Ting, Chien-Kun; Hsu, Jia-Ruei; Huang, Chih-Chung; Chang, Yin; Chen, Gin-Shin
2017-09-01
Ultrasound guidance for epidural block has improved clinical blind-trial problems but the design of present ultrasonic probes poses operating difficulty of ultrasound-guided catheterization, increasing the failure rate. The purpose of this study was to develop a novel ultrasonic probe to avoid needle contact with vertebral bone during epidural catheterization. The probe has a central circular passage for needle insertion. Two focused annular transducers are deployed around the passage for on-axis guidance. A 17-gauge insulated Tuohy needle containing the self-developed fiber-optic-modified stylet was inserted into the back of the anesthetized pig, in the lumbar region under the guidance of our ultrasonic probe. The inner transducer of the probe detected the shallow echo signals of the peak-peak amplitude of 2.8 V over L3 at the depth of 2.4 cm, and the amplitude was decreased to 0.8 V directly over the L3 to L4 interspace. The outer transducer could detect the echoes from the deeper bone at the depth of 4.5 cm, which did not appear for the inner transducer. The operator tilted the probe slightly in left-right and cranial-caudal directions until the echoes at the depth of 4.5 cm disappeared, and the epidural needle was inserted through the central passage of the probe. The needle was advanced and stopped when the epidural space was identified by optical technique. The needle passed without bone contact. Designs of the hollow probe for needle pass and dual transducers with different focal lengths for detection of shallow and deep vertebrae may benefit operation, bone/nonbone identification, and cost.
Neal, Joseph M; Brull, Richard; Horn, Jean-Louis; Liu, Spencer S; McCartney, Colin J L; Perlas, Anahi; Salinas, Francis V; Tsui, Ban Chi-Ho
2016-01-01
In 2009 and again in 2012, the American Society of Regional Anesthesia and Pain Medicine assembled an expert panel to assess the evidence basis for ultrasound guidance as a nerve localization tool for regional anesthesia. The 2012 panel reviewed evidence from the first advisory but focused primarily on new information that had emerged since 2009. A new section was added regarding the accuracy and reliability of ultrasound for determining needle-to-nerve proximity. Jadad scores are used to rank study quality. Grades of recommendations consistent with their level of evidence are provided. The panel offers recommendations based on synthesis and analysis of literature related to (1) the technical capabilities of ultrasound equipment and its operators, (2) comparison of ultrasound to other methods of nerve localization with regard to block characteristics, (3) comparison of block techniques where ultrasound is the sole nerve localization modality, and (4) major complications. Assessment of evidence strength and recommendations are made for upper- and lower-extremity, truncal, neuraxial, and pediatric blocks. Scientific evidence from the past 5 years has clarified and strengthened our understanding of ultrasound-guided regional anesthesia as a nerve localization tool. High-level evidence supports ultrasound guidance contributing to superior characteristics with selected blocks, although absolute differences with the comparator technique are often relatively small (especially for upper-extremity blocks). The clinical meaningfulness of these differences is likely of variable importance to individual practitioners. The use of ultrasound significantly reduces the risk of local anesthetic systemic toxicity as well as the incidence and intensity of hemidiaphragmatic paresis, but has no significant effect on the incidence of postoperative neurologic symptoms. WHAT'S NEW IN THIS UPDATE?: This evidence-based assessment of ultrasound-guided regional anesthesia reviews findings from our 2010 publication and focuses on new meta-analyses, randomized controlled trials, and large case series published since 2009. New to this exercise is an in-depth analysis of the accuracy and reliability of ultrasound guidance for identifying needle-to-nerve relationships. This version no longer addresses ultrasound for interventional pain medicine procedures, because the growth of that field demands separate consideration. Since our 2010 publication, new information has either supported or strengthened our original conclusions. There is no evidence that ultrasound is inferior to alternative nerve localization methods.
Jin, Cheng S.; Wada, Hironobu; Anayama, Takashi; McVeigh, Patrick Z; Hu, Hsin Pei; Hirohashi, Kentaro; Nakajima, Takahiro; Kato, Tatsuya; Keshavjee, Shaf; Hwang, David; Wilson, Brian C.; Zheng, Gang; Yasufuku, Kazuhiro
2016-01-01
Early detection and efficient treatment modality of early-stage peripheral lung cancer is essential. Current non-surgical treatments for peripheral lung cancer show critical limitations associated with various complications, requiring alternative minimally invasive therapeutics. Porphysome nanoparticle-enabled fluorescence-guided transbronchial photothermal therapy (PTT) of peripheral lung cancer was developed and demonstrated in preclinical animal models. Systemically-administered porphysomes accumulated in lung tumors with significantly enhanced disease-to-normal tissue contrast, as confirmed in three subtypes of orthotopic human lung cancer xenografts (A549, H460 and H520) in mice and in an orthotopic VX2 tumor in rabbits. An in-house prototype fluorescence bronchoscope demonstrated the capability of porphysomes for in vivo imaging of lung tumors in the mucosal/submucosal layers, providing real-time fluorescence guidance for transbronchial PTT. Porphysomes also enhanced the efficacy of transbronchial PTT significantly and resulted in selective and efficient tumor tissue ablation in the rabbit model. A clinically used cylindrical diffuser fiber successfully achieved tumor-specific thermal ablation, showing promising evidence for the clinical translation of this novel platform to impact upon non-surgical treatment of early-stage peripheral lung cancer. PMID:27543602
Siddiqui, EJ; Ali, S; Koneru, S
2006-01-01
INTRODUCTION Transrectal ultrasound guided prostate needle biopsy (TRUS) is the standard procedure to diagnose or exclude prostate cancer. This procedure can be associated with significant discomfort, both on insertion of the ultrasound probe as well as on taking the biopsy. We evaluated a new technique for pain relief during TRUS biopsy. PATIENTS AND METHODS In Group 1 (n = 60), the biopsies were taken without any analgesia. In Group 2 (n = 60), 11 ml of Instillagel (2% lignocaine) was administered rectally prior to probe insertion and 5 ml of 1% lignocaine periprostatic injection was administered before taking the biopsy. The discomfort encountered during the procedure was graded by the patient on a scale ranging from no discomfort to mild, moderate and severe pain. RESULTS In Group 2, there was a marked reduction in the pain experienced during the procedure. The Chi-squared test for trend showed a significant association between the rectal administration of local anaesthetic gel and reduction in pain on probe insertion (P = 0.0001). There was also a significant association between the use of periprostatic lignocaine injection and reduction in pain on taking the biopsy (P < 0.0001). CONCLUSIONS The use of lignocaine gel prior to probe insertion and periprostatic infiltration of lignocaine before taking the needle biopsy significantly reduces the pain experienced by the patient during TRUS-guided prostate biopsy. PMID:16551424
Siebert, Frank-André; Hirt, Markus; Niehoff, Peter; Kovács, György
2009-08-01
Ultrasound imaging is becoming increasingly important in prostate brachytherapy. In high-dose-rate (HDR) real-time planning procedures the definition of the implant needles is often performed by transrectal ultrasound. This article describes absolute measurements of the visibility and accuracy of manual detection of implant needle tips and compares measurement results of different biplane ultrasound systems in transversal and longitudinal (i.e., sagittal) ultrasound modes. To obtain a fixed coordinate system and stable conditions the measurements were carried out in a water tank using a dedicated marker system. Needles were manually placed in the phantom until the observer decided by the real-time ultrasound image that the zero position was reached. A comparison of three different ultrasound systems yielded an offset between 0.8 and 3.1 mm for manual detection of the needle tip in ultrasound images by one observer. The direction of the offset was discovered to be in the proximal direction, i.e., the actual needle position was located more distally compared to the ultrasound-based definition. In the second part of the study, the ultrasound anisotropy of trocar implant needles is reported. It was shown that the integrated optical density in a region of interest around the needle tip changes with needle rotation. Three peaks were observed with a phase angle of 120 degrees. Peaks appear not only in transversal but also in longitudinal ultrasound images, with a phase shift of 60 degrees. The third section of this study shows results of observer dependent influences on needle tip detection in sagittal ultrasound images considering needle rotation. These experiments were carried out using the marker system in a water tank. The needle tip was placed exactly at the position z=0 mm. It was found that different users tend to differently interpret the same ultrasound images. The needle tip was manually detected five times in the ultrasound images by three experienced observers at positions (+/- standard deviation) -0.53 +/- 0.16, -0.16 +/- 0.14, and -0.30 +/- 0.16 mm using a gain of 15 dB. The minus sign indicates that the needle tips were detected more proximally than the actual position of the needle tip. When using a gain of -15 dB the mean values of two observers resulted in -0.62 +/- 0.08 and -0.51 +/- 0.12 mm. Additionally an alternative approach to the direct needle tip definition was investigated. Two observers detected the solid part of the needle tip in sagittal images. This solid part, often named as "dead space end," is the distance between the needle tip and the beginning of the hollow part of the implant needle. The dead space end is 6.2 mm for the investigated needle type. Two users found mean values of -6.70 +/- 0.16 and -7.00 +/- 0.06 mm, respectively, for 15 dB gain and -6.90 +/- 0.09 and -7.02 +/- 0.06 mm using the -15 dB gain setting. The results show that ultrasound-based needle tip definition in sagittal viewing mode is accurate. The inter- and intraobserver errors should, however, be taken into account. A lower gain setting of the ultrasound system reduces the intraobserver error.
Dhooria, Sahajal; Gupta, Nalini; Bal, Amanjit; Sehgal, Inderpaul Singh; Aggarwal, Ashutosh Nath; Sethi, Sunil; Behera, Digambar; Agarwal, Ritesh
2016-10-07
In patients with intrathoracic lymphadenopathy, differentiating tuberculosis from sarcoidosis is often difficult. We hypothesized that Xpert MTB/RIF assay, a semi-automated hemi-nested PCR would help in this regard. To evaluate the performance of Xpert MTB/RIF in the differential diagnosis of tuberculosis and sarcoidosis. This was a retrospective analysis of patients with intrathoracic lymphadenopathy who underwent endobronchial ultrasound (EBUS)-guided transbronchial needle aspiration (TBNA), and were diagnosed as either tuberculosis or sarcoidosis. The results of Xpert MTB/RIF assay, tuberculin skin test and endosonographic characteristics (heterogeneous echotexture and coagulation necrosis sign) of the lymph nodes were compared between the two groups. During the study period, 465 EBUS procedures were performed and a diagnosis of sarcoidosis (n=94) or tuberculosis (n=53) was made in 147 patients. Xpert MTB/RIF was positive in 26 (49.1%) and two (2.1%) patients with tuberculosis and sarcoidosis, respectively. The sensitivity, specificity, positive and negative predictive values of Xpert MTB/RIF in the diagnosis of tuberculosis were 49.1 %, 97.9%, 92.9% and 77.3%, respectively. The presence of any of the four features namely positive Xpert MTB/RIF, positive tuberculin skin test, heterogeneous echotexture of the lymph nodes, or the presence of endosonographic coagulation necrosis sign yielded a sensitivity and negative predictive value of 83.0% and 88.0%, respectively in the diagnosis of tuberculosis versus sarcoidosis. Xpert MTB/RIF has good specificity and positive predictive value in the diagnosis of tuberculosis, and is a useful investigation in separating tuberculosis from sarcoidosis.
Sarcoidosis: a state of the art review from the Thoracic Society of Australia and New Zealand.
Ahmadzai, Hasib; Huang, Shuying; Steinfort, Chris; Markos, James; Allen, Roger Ka; Wakefield, Denis; Wilsher, Margaret; Thomas, Paul S
2018-06-18
Sarcoidosis is a systemic disease of unknown aetiology, characterised by non-caseating granulomatous inflammation. It most commonly manifests in the lungs and intrathoracic lymph nodes but can affect any organ. This summary of an educational resource provided by the Thoracic Society of Australia and New Zealand outlines the current understanding of sarcoidosis and highlights the need for further research. Our knowledge of the aetiology and immunopathogenesis of sarcoidosis remains incomplete. The enigma of sarcoidosis lies in its immunological paradox of type 1 T helper cell-dominated local inflammation co-existing with T regulatory-induced peripheral anergy. Although specific aetiological agents have not been identified, mounting evidence suggests that environmental and microbial antigens may trigger sarcoidosis. Genome-wide association studies have identified candidate genes conferring susceptibility and gene expression analyses have provided insights into cytokine dysregulation leading to inflammation. Sarcoidosis remains a diagnosis of exclusion based on histological evidence of non-caseating granulomas with compatible clinical and radiological findings. In recent years, endobronchial ultrasound-guided transbronchial needle aspiration of mediastinal lymph nodes has facilitated the diagnosis, and whole body positron emission tomography scanning has improved localisation of disease. No single biomarker is adequately sensitive and specific for detecting and monitoring disease activity. Most patients do not require treatment; when indicated, corticosteroids remain the initial standard of care, despite their adverse side effect profile. Other drugs with fewer side effects may be a better long term choice (eg, methotrexate, hydroxychloroquine, azathioprine, mycophenolate), while tumour necrosis factor-α inhibitors are a treatment option for patients with refractory disease.
Jeyapalan, Kanagaratnam; Choudhary, Surabhi
2009-11-01
The aim of this study was to describe the technique and usefulness of ultrasound-guided intrasynovial injection of triamcinolone and bupivacaine in treatment of de Quervain's disease. A total of 17 patients with symptomatic De Quervain's disease were included in this study. The procedure involved confirmation of diagnosis with ultrasound followed by guided injection of a mixture of 20 mg of triamcinolone (40 mg/ml) and 1 ml of 0.5% bupivacaine. Ultrasound guidance with a high resolution 15-Mhz footprint probe was used for injection into the first dorsal extensor compartment tendon sheath (E1). The response to ultrasound-guided injection was ascertained at the post procedure outpatient clinic appointment according to the follow-up clinic notes. There were 14 female and 3 male patients aged 29 to 74 years. Mean duration of symptoms was 8.9 months. One patient had an atypical septum in the first extensor compartment and the extensor pollicis brevis alone was involved. The mean post-injection follow-up was at 6.75 weeks. One patient was lost to follow-up. Fifteen out of 16 patients had significant symptomatic relief (93.75%). There were no immediate or delayed complications. Recurrence of symptoms was seen in 3 (20%) patients. Ultrasound-guided injection of triamcinolone and bupivacaine is safe and useful in controlling symptoms of De Quervain's disease. Correct needle placement with ultrasound guidance avoids intratendinous injection as well as local complications like fat atrophy and depigmentation.
Bang, Ji Young; Navaneethan, Udayakumar; Hasan, Muhammad K; Hawes, Robert; Varadarajulu, Shyam
2018-03-11
Outcomes of endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) evaluation vary with technique, needles, and methods of specimen evaluation. We performed a direct comparison of diagnostic yields of EUS-FNA samples collected using different gauge needles (22- vs 25-gauge), with or without suction. We performed a randomized controlled study of 352 patients with suspected pancreatic masses, referred for EUS-FNA at a tertiary referral center. Patients were randomly assigned to 22-gauge needles with or without suction or 25-gauge needles with or without suction. Specimens were evaluated offsite by cell block and rapid onsite cytologic evaluation (ROSE). Final diagnoses were made based on histologic analyses or 12-month follow-up evaluations. The primary outcome was diagnostic adequacy of cell blocks. Secondary outcomes were operating characteristics of ROSE and EUS-FNA, number of passes required for accurate onsite diagnosis, and amount of blood in specimens. The final diagnoses were malignancy (81.5% of patients) and benign disease (17.0% of patients); 1.4% of patients were lost during follow up. Cell block, ROSE, and EUS-FNA led to diagnostic accuracies of 71.9%, 95.5%, and 96.6%, respectively. A 22-gauge needle with suction was associated with more passes for adequate onsite diagnosis (P = .003) and specimens contained more blood (P = .01). Diagnostic accuracy of specimens collected by transduodenal EUS-FNA was lower with 22-gauge needles with suction compared to other techniques (P = .004). In a randomized trial of patients undergoing EUS-FNA for pancreatic masses, samples collected with 22-gauge vs 25-gauge needles performed equally well for offsite specimen evaluation. Use of suction appears to increase number of passes needed and specimen bloodiness. Specimen collection techniques should be individualized based on method of evaluation. ClinicalTrials.gov no: NCT02424838. Copyright © 2018 AGA Institute. Published by Elsevier Inc. All rights reserved.
Dong, YiJie; Mao, MinJing; Zhan, WeiWei; Zhou, JianQiao; Zhou, Wei; Yao, JieJie; Hu, YunYun; Wang, Yan; Ye, TingJun
2018-06-01
Our goal was to assess the diagnostic efficacy of ultrasound (US)-guided fine-needle aspiration (FNA) of thyroid nodules according to size and US features. A retrospective correlation was made with 1745 whole thyroidectomy and hemithyroidectomy specimens with preoperative US-guided FNA results. All cases were divided into 5 groups according to nodule size (≤5, 5.1-10, 10.1-15, 15.1-20, and >20 mm). For target nodules, static images and cine clips of conventional US and color Doppler were obtained. Ultrasound images were reviewed and evaluated by two radiologists with at least 5 years US working experience without knowing the results of pathology, and then agreement was achieved. The Bethesda category I rate was higher in nodules larger than 15 mm (P < .05). The diagnostic accuracy was best in nodules of 5 to 10 mm in diameter. The sensitivity, accuracy, PPV, and LR for negative US-guided FNA results were better in nodules with a size range of 5 to 15 mm. The specificity, negative predictive value (NPV), and LR for positive results and the Youden index rose with increasing nodule size. Seventeen false-positive and 60 false-negative results were found in this study. The false-negative rate rose with increasing nodule size. However, the false-positive rate was highest in the group containing the smallest nodules. Nodules with circumscribed margins and those that were nonsolid and nonhypoechoic and had no microcalcifications correlated with Bethesda I FNA results. Nodules with circumscribed margins and those that were nonsolid, heterogeneous, and nonhypoechoic and had increased vascularity correlated with false-negative FNA results. Borders correlated with Bethesda I false-negative and false-positive FNA results. Tiny nodules (≤5 mm) with obscure borders tended to yield false-positive FNA results. Large nodules (>20 mm) with several US features tended to yield false-negative FNA results. © 2017 by the American Institute of Ultrasound in Medicine.
Development of a 3D ultrasound-guided prostate biopsy system
NASA Astrophysics Data System (ADS)
Cool, Derek; Sherebrin, Shi; Izawa, Jonathan; Fenster, Aaron
2007-03-01
Biopsy of the prostate using ultrasound guidance is the clinical gold standard for diagnosis of prostate adenocarinoma. However, because early stage tumors are rarely visible under US, the procedure carries high false-negative rates and often patients require multiple biopsies before cancer is detected. To improve cancer detection, it is imperative that throughout the biopsy procedure, physicians know where they are within the prostate and where they have sampled during prior biopsies. The current biopsy procedure is limited to using only 2D ultrasound images to find and record target biopsy core sample sites. This information leaves ambiguity as the physician tries to interpret the 2D information and apply it to their 3D workspace. We have developed a 3D ultrasound-guided prostate biopsy system that provides 3D intra-biopsy information to physicians for needle guidance and biopsy location recording. The system is designed to conform to the workflow of the current prostate biopsy procedure, making it easier for clinical integration. In this paper, we describe the system design and validate its accuracy by performing an in vitro biopsy procedure on US/CT multi-modal patient-specific prostate phantoms. A clinical sextant biopsy was performed by a urologist on the phantoms and the 3D models of the prostates were generated with volume errors less than 4% and mean boundary errors of less than 1 mm. Using the 3D biopsy system, needles were guided to within 1.36 +/- 0.83 mm of 3D targets and the position of the biopsy sites were accurately localized to 1.06 +/- 0.89 mm for the two prostates.
Kunz, Derek; Pariyadath, Manoj; Wittler, Mary; Askew, Kim; Manthey, David; Hartman, Nicholas
2017-06-01
Arthrocentesis is an important skill for physicians in multiple specialties. Recent studies indicate a superior safety and performance profile for this procedure using ultrasound guidance for needle placement, and improving quality of care requires a valid measurement of competency using this modality. We endeavored to create a validated tool to assess the performance of this procedure using the modified Delphi technique and experts in multiple disciplines across the United States. We derived a 22-item checklist designed to assess competency for the completion of ultrasound-guided arthrocentesis, which demonstrated a Cronbach's alpha of 0.89, indicating an excellent degree of internal consistency. Although we were able to demonstrate content validity for this tool, further validity evidence should be acquired after the tool is used and studied in clinical and simulated contexts. © 2017 by the American Institute of Ultrasound in Medicine.
Plantar fascia: imaging diagnosis and guided treatment.
McNally, Eugene G; Shetty, Shilpa
2010-09-01
Plantar fasciopathy is a common cause of heel pain. This article covers the imaging anatomy of the hindfoot, the imaging findings on ultrasound and magnetic resonance imaging (MRI) of plantar fasciopathy, plantar fibromas, trauma, Achilles tendonopathy, neural compression, stress fractures of the os calcis and other heel pad lesions. Thickening of the plantar fascia insertion more than 5 mm either on ultrasound or MRI is suggestive of plantar fasciopathy. Ultrasound is superior to MRI for diagnosis of plantar fibroma as small low signal lesions on MRI are similar to the normal plantar fascia signal. Ultrasound demonstrates low echogenicity compared with the echogenic plantar fascia. Penetrating injuries can appear bizarre due to associated foreign body impaction and infection. Achilles tendonopathy can cause heel pain and should be considered as a possible diagnosis. Treatment options include physical therapy, ECSWT, corticosteroid injection, and dry needling. Percutaneous US guided treatment methods will be described. Thieme Medical Publishers.
NASA Astrophysics Data System (ADS)
Irisawa, Kaku; Murakoshi, Dai; Hashimoto, Atsushi; Yamamoto, Katsuya; Hayakawa, Toshiro
2017-03-01
Visualization of the tip of medical devices like needles or catheters under ultrasound imaging has been a continuous topic since the early 1980's. In this study, a needle tip visualization system utilizing photoacoustic effects is proposed. In order to visualize the needle tip, an optical fiber was inserted into a needle. The optical fiber tip is placed on the needle bevel and affixed with black glue. The pulsed laser light from laser diode was transferred to the optical fiber and converted to ultrasound due to laser light absorption of the black glue and the subsequent photoacoustic effect. The ultrasound is detected by transducer array and reconstructed into photoacoustic images in the ultrasound unit. The photoacoustic image is displayed with a superposed ultrasound B-mode image. As a system evaluation, the needle is punctured into bovine meat and the needle tip is observed with commercialized conventional linear transducers or convex transducers. The needle tip is visualized clearly at 7 and 12 cm depths with linear and convex probes, respectively, even with a steep needle puncture angle of around 90 degrees. Laser and acoustic outputs, and thermal rise at the needle tip, were measured and were well below the limits of the safety standards. Compared with existing needle tip visualization technologies, the photoacoustic needle tip visualization system has potential distinguishable features for clinical procedures related with needle puncture and injection.
Lean Six Sigma Applied to Ultrasound Guided Needle Biopsy in the Head and Neck.
Matt, Bruce H; Woodward-Hagg, Heather K; Wade, Christopher L; Butler, Penny D; Kokoska, Mimi S
2014-07-01
(1) Confirm the positive value stream of office-based ultrasound using Lean Six Sigma; (2) demonstrate how ultrasound reduces time to diagnosis, costs, patient inconvenience and travel, exposure to ionizing radiation, intravenous contrast, and laboratory tests. Case series with historical controls using chart review. Tertiary Veterans Administration Hospital (university-affiliated). Patients with a consult request or decision for ultrasound guided fine needle aspiration (USFNA) from 2006 to 2012. Process evaluation using Lean Six Sigma methodologies; years study conducted: 2006-2012; outcome measurements: type of diagnostic tests and imaging studies including CT scans with associated radiation exposure, time to preliminary and final cytopathologic diagnosis, episodes of patient travel. Value stream mapping prior to and after implementing office-based ultrasound confirmed the time from consult request or decision for USFNA to completion of the USFNA was reduced from a range of 0 to 286 days requiring a maximum 17 steps to a range of 0 to 48 days, necessitating only a maximum of 9 steps. Office-based USFNA for evaluation of head and neck lesions reduced costs, time to diagnosis, risks and inconvenience to patients, radiation exposure, unnecessary laboratory, and patient complaints while increasing staff satisfaction. In addition, office-based ultrasound also changed the clinical management of specific patients. Lean Six Sigma reduces waste and optimizes quality and accuracy in manufacturing. This is the first known application of Lean Six Sigma to office-based USFNA in the evaluation of head and neck lesions. The literature supports the value of office-based ultrasound to patients and health care systems. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2014.
NASA Astrophysics Data System (ADS)
Samboju, Vishal; Adams, Matthew; Salgaonkar, Vasant; Diederich, Chris J.; Cunha, J. Adam M.
2017-02-01
The speed of sound (SOS) for ultrasound devices used for imaging soft tissue is often calibrated to water, 1540 m/s1 , despite in-vivo soft tissue SOS varying from 1450 to 1613 m/s2 . Images acquired with 1540 m/s and used in conjunction with stereotactic external coordinate systems can thus result in displacement errors of several millimeters. Ultrasound imaging systems are routinely used to guide interventional thermal ablation and cryoablation devices, or radiation sources for brachytherapy3 . Brachytherapy uses small radioactive pellets, inserted interstitially with needles under ultrasound guidance, to eradicate cancerous tissue4 . Since the radiation dose diminishes with distance from the pellet as 1/r2 , imaging uncertainty of a few millimeters can result in significant erroneous dose delivery5,6. Likewise, modeling of power deposition and thermal dose accumulations from ablative sources are also prone to errors due to placement offsets from SOS errors7 . This work presents a method of mitigating needle placement error due to SOS variances without the need of ionizing radiation2,8. We demonstrate the effects of changes in dosimetry in a prostate brachytherapy environment due to patientspecific SOS variances and the ability to mitigate dose delivery uncertainty. Electromagnetic (EM) sensors embedded in the brachytherapy ultrasound system provide information regarding 3D position and orientation of the ultrasound array. Algorithms using data from these two modalities are used to correct bmode images to account for SOS errors. While ultrasound localization resulted in >3 mm displacements, EM resolution was verified to <1 mm precision using custom-built phantoms with various SOS, showing 1% accuracy in SOS measurement.
Quezada-Gaon, Natacha; Wortsman, Ximena; Peñaloza, Osvaldo; Carrasco, Juan Eduardo
2016-09-01
Botulinum toxin type A has been used for treating the hypertrophy of the masseter muscles and its cosmetic effects. Ultrasound is increasingly used in dermatology, along with the guidance of mini-invasive procedures. To evaluate the role of ultrasound for guiding the application of Botulinum A toxin in patients with cosmetic alterations due to bruxism, correlate the clinical landmarks with the ultrasound findings, and study the effect on the symptoms, cosmetics, and quality of life. Twenty individuals with bruxism and cosmetic alterations underwent an ultrasound-guided injection of Botulinum toxin type A in each masseter muscle. Clinical and ultrasound marking of the procedure was compared. Clinical and sonographic evaluation was performed at the time of injection and 3 months later. Ten normal individuals underwent ultrasound of the masseter muscles as a control group. Up to 65% of individuals showed anatomical variants of the salivary glands. The method for clinically marking the skin showed a frequently erroneous location of the anterior point (up to 40% of cases) that was proven by ultrasound to be out of the muscle. In 20% of cases, ultrasound showed that the needle should be longer to enter the muscle. After injection, most of the patients demonstrated a decrease of the symptoms and cosmetic and quality of life improvements. Ultrasound can be a potent tool for guiding the injection of Botulinum toxin into the masseter muscles. It may contribute to a more personalized procedure, better cosmetic results, and help to avoid potential complications. © 2016 Wiley Periodicals, Inc.
Kao, Steven D; Morshedi, Maud M; Narsinh, Kazim H; Kinney, Thomas B; Minocha, Jeet; Picel, Andrew C; Newton, Isabel; Rose, Steven C; Roberts, Anne C; Kuo, Alexander; Aryafar, Hamed
2016-08-01
To assess whether intravascular ultrasound (US) guidance impacts number of needle passes, contrast usage, radiation dose, and procedure time during creation of transjugular intrahepatic portosystemic shunts (TIPS). Intravascular US-guided creation of TIPS in 40 patients was retrospectively compared with conventional TIPS in 49 patients between February 2010 and November 2015 at a single tertiary care institution. Patient sex and age, etiology of liver disease (hepatitis C virus, alcohol abuse, nonalcoholic steatohepatitis), severity of liver disease (mean Model for End-Stage Liver Disease score), and indications for TIPS (variceal bleeding, refractory ascites, refractory hydrothorax) in conventional and intravascular US-guided cases were recorded. The two groups were well matched by sex, age, etiology of liver disease, Child-Pugh class, Model for End-Stage Liver Disease scores, and indication for TIPS (P range = .19-.94). Fewer intrahepatic needle passes were required in intravascular US-guided TIPS creation compared with conventional TIPS (2 passes vs 6 passes, P < .01). Less iodinated contrast material was used in intravascular US cases (57 mL vs 140 mL, P < .01). Radiation exposure, as measured by cumulative dose, dose area product, and fluoroscopy time, was reduced with intravascular US (174 mGy vs 981 mGy, P < .01; 3,793 μGy * m(2) vs 21,414 μGy * m(2), P < .01; 19 min vs 34 min, P < .01). Procedure time was shortened with intravascular US (86 min vs 125 min, P < .01). Intravascular US guidance resulted in fewer intrahepatic needle passes, decreased contrast medium usage, decreased radiation dosage, and shortened procedure time in TIPS creation. Copyright © 2016 SIR. All rights reserved.
A new technical contribution for ultrasound-guided injections of sacro-iliac joints.
Migliore, A; Bizzi, E; Massafra, U; Vacca, F; Martin-Martin, L S; Granata, M; Tormenta, S
2010-05-01
Sacroiliac joint (SIJ) represents a difficult location for local therapies, as intra-articular injections may be hard to execute, especially in particular conditions such as chronic inflammatory diseases. However, in selected patients, local therapies may be considered. Some recent studies demonstrated the feasibility of ultrasound (US)-guided injection of SIJ, but still a complete explanation and definition of the technique is needed. Seven patients, four males and 3 females, affected by mono or bilateral sacroiliitis entered the study. Each patient received 40 mg of acetonide triamcinolone for each SIJ, intra articular (IA) US-guided injection. The technical originality proposed in this study consists in the spinal needle insertion in the middle of the cranial long side of the linear transducer with an orientation of about 10 degrees, determining shorter needle insertion for reaching joint space and consequently probably granting lesser pain and traumatism for patients. A total of 22 injections was performed. The longer follow-up time obtained was 18 months in 3 patients. All patients reached at least a 6 month follow-up. All patients reported an amelioration in pain that lasted for at least 6 months. No systemic adverse events were reported or observed. Complete visualization of SIJ and of needle placement was performed by US imaging, while compound proper injection was also visualized by Color-Doppler US imaging. Actually, sacroiliac joint intraarticular injections are often performed under fluoroscopy or Computerized Tomography guidance. Such techniques present several limitations, especially for repeated injections, such as the use of ionizing radiations, the need of a contrast agent and the direct and indirect costs connected. US guidance in IA SIJ injections may represent an easily repeatable imaging technique for needle placement and a precious tool for detecting inflammatory activity of the joint.
Paris, Ida; Prelaj, Arsela; Onesti, Concetta Elisa; Baldoni, Alessandra; Giovagnoli, Maria Rosaria; Bassanelli, Maria; Lauro, Salvatore; Marchetti, Paolo
2014-01-01
The occurrence of radiological mediastinal lymphadenopathy as the only evidence of tumor recurrence of cervical carcinoma is very rare. We report on such a case with stenosis of the esophagus. A 36-year-old Caucasian woman, without any relevant history of gynecological cancer, underwent a trans-vaginal ultrasound with evidence of any cervical lesion locally extended. After histologically-proven diagnosis of squamous cell carcinoma of the cervix uterine, the patient was treated by neoadjuvant chemoradiation, followed by total abdominal hysterectomy with bilateral salpingoophorectomy. A subsequent close follow-up was negative for recurrence of disease until December 2008, two years after diagnosis. At that period, the patient experienced cough and severe dysphagia and for this reason she underwent several examinations including esophagogastroduodenoscopy, whole-body computed tomographic scan and bronchoscopy with transbronchial needle aspiration. Histology led to diagnosis of recurrence of cervical cancer, HPV31-positive, in multiple mediastinal lymphnodes, with infiltration of the esophageal mucosa. Mediastinal lymphade-nopathy in patients with a history of cervical carcinoma should be suspicious of metastatic disease, even if there is no radiological evidence of distant metastases.
Automatic needle segmentation in 3D ultrasound images using 3D Hough transform
NASA Astrophysics Data System (ADS)
Zhou, Hua; Qiu, Wu; Ding, Mingyue; Zhang, Songgeng
2007-12-01
3D ultrasound (US) is a new technology that can be used for a variety of diagnostic applications, such as obstetrical, vascular, and urological imaging, and has been explored greatly potential in the applications of image-guided surgery and therapy. Uterine adenoma and uterine bleeding are the two most prevalent diseases in Chinese woman, and a minimally invasive ablation system using an RF button electrode which is needle-like is being used to destroy tumor cells or stop bleeding currently. Now a 3D US guidance system has been developed to avoid accidents or death of the patient by inaccurate localizations of the electrode and the tumor position during treatment. In this paper, we described two automated techniques, the 3D Hough Transform (3DHT) and the 3D Randomized Hough Transform (3DRHT), which is potentially fast, accurate, and robust to provide needle segmentation in 3D US image for use of 3D US imaging guidance. Based on the representation (Φ , θ , ρ , α ) of straight lines in 3D space, we used the 3DHT algorithm to segment needles successfully assumed that the approximate needle position and orientation are known in priori. The 3DRHT algorithm was developed to detect needles quickly without any information of the 3D US images. The needle segmentation techniques were evaluated using the 3D US images acquired by scanning water phantoms. The experiments demonstrated the feasibility of two 3D needle segmentation algorithms described in this paper.
Endoscopic Ultrasound of the Upper Gastrointestinal Tract and Mediastinum: Diagnosis and Therapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Prasad, Priyajit; Wittmann, Johannes; Pereira, Stephen P.
2006-12-15
Endoscopic ultrasound (EUS) has developed significantly over the last two decades and has had a considerable impact on the imaging and staging of mass lesions within or in close proximity to the gastrointestinal (GI) tract. In conjunction with conventional imaging such as helical computed tomography and magnetic resonance imaging, the indications for EUS include (1) differentiating between benign and malignant lesions of the mediastinum and upper GI tract, (2) staging malignant tumors of the lung, esophagus, stomach, and pancreas prior to surgery or oncological treatment, (3) excluding common bile duct stones before laparoscopic cholecystectomy, thereby avoiding the need for endoscopicmore » retrograde cholangiopancreatography (ERCP) in some patients, and (4) assessing suspected lesions that are either equivocal or not seen on conventional imaging. In recent years, EUS has charted a course similar to that taken by ERCP, evolving from a purely diagnostic modality to one that is interventional and therapeutic. These indications include (5) obtaining a tissue diagnosis by EUS-guided fine-needle aspiration or trucut-type needle biopsy and (6) providing therapy such as coeliac plexus neurolysis and pancreatic pseudocyst drainage-in many cases, more accurately and safely than conventional techniques. Emerging investigational techniques include EUS-guided enteric anastomosis formation and fine-needle injection therapy for malignant disease.« less
Antonini, Filippo; Fuccio, Lorenzo; Giorgini, Sara; Fabbri, Carlo; Frazzoni, Leonardo; Scarpelli, Marina; Macarri, Giampiero
2017-08-01
While the presence of biliary stent significantly decreases the accuracy of endoscopic ultrasound (EUS) for pancreatic head cancer staging, its impact on the EUS-guided sampling accuracy is still debated. Furthermore, data on EUS-fine needle biopsy (EUS-FNB) using core biopsy needles in patients with pancreatic mass and biliary stent are lacking. The aim of this study was to evaluate the influence of biliary stent on the adequacy and accuracy of EUS-FNB in patients with pancreatic head mass. All patients who underwent EUS-guided sampling with core needles of solid pancreatic head masses causing obstructive jaundice were retrospectively identified in a single tertiary referral center. Adequacy, defined as the rate of cases in which a tissue specimen for proper examination was achieved, with and without biliary stent, was the primary outcome measure. The diagnostic accuracy and complication rate were the secondary outcome measures. A total of 130 patients with pancreatic head mass causing biliary obstruction were included in the study: 74 cases of them were sampled without stent and 56 cases with plastic stent in situ. The adequacy was 96.4% in the stent group and 90.5% in the group without stent (p=0.190). No significant differences were observed for sensitivity (88.9% vs. 85.9%), specificity (100% for both groups), and accuracy (89.3% vs. 86.5%) between those with and without stent, respectively. The accuracy was not influenced by the timing of stenting (<48h or ≥48h before EUS). No EUS-FNB related complications were recorded. The presence of biliary stent does not influence the tissue sampling adequacy, the diagnostic accuracy and the complication rate of EUS-FNB of pancreatic head masses performed with core biopsy needles. Copyright © 2017 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Armstrong, G.; Cardon, L.; Vilkomerson, D.; Lipson, D.; Wong, J.; Rodriguez, L. L.; Thomas, J. D.; Griffin, B. P.
2001-01-01
This study evaluates a new device that uses color Doppler ultrasonography to enable real-time image guidance of the aspirating needle, which has not been possible until now. The ColorMark device (EchoCath Inc, Princeton, NJ) induces high-frequency, low-amplitude vibrations in the needle to enable localization with color Doppler. We studied this technique in 25 consecutive patients undergoing pericardiocentesis, and in vitro, in a urethane phantom with which the accuracy of color Doppler localization of the needle tip was compared with that obtained by direct measurement. Tip localization was excellent in vitro; errors axial to the ultrasound beam (velocity Doppler -0.13 +/- 0.90 mm, power Doppler -0.05 +/- 1.7 mm) were less than lateral errors (velocity -0.36 +/- 1.8 mm, power -0.02 +/- 2.8 mm). In 18 of 25 patients, the needle was identified and guided into the pericardial space with the ColorMark technique, and it allowed successful, uncomplicated drainage of fluid. Initial failures were the result of incorrect settings on the echocardiographic machine and inappropriate combinations of the needle puncture site and imaging window. This study demonstrates a novel color Doppler technique that is highly accurate at localizing a needle tip. The technique is feasible for guiding pericardiocentesis. Further clinical validation of this technique is required.
Multi-resolution Gabor wavelet feature extraction for needle detection in 3D ultrasound
NASA Astrophysics Data System (ADS)
Pourtaherian, Arash; Zinger, Svitlana; Mihajlovic, Nenad; de With, Peter H. N.; Huang, Jinfeng; Ng, Gary C.; Korsten, Hendrikus H. M.
2015-12-01
Ultrasound imaging is employed for needle guidance in various minimally invasive procedures such as biopsy guidance, regional anesthesia and brachytherapy. Unfortunately, a needle guidance using 2D ultrasound is very challenging, due to a poor needle visibility and a limited field of view. Nowadays, 3D ultrasound systems are available and more widely used. Consequently, with an appropriate 3D image-based needle detection technique, needle guidance and interventions may significantly be improved and simplified. In this paper, we present a multi-resolution Gabor transformation for an automated and reliable extraction of the needle-like structures in a 3D ultrasound volume. We study and identify the best combination of the Gabor wavelet frequencies. High precision in detecting the needle voxels leads to a robust and accurate localization of the needle for the intervention support. Evaluation in several ex-vivo cases shows that the multi-resolution analysis significantly improves the precision of the needle voxel detection from 0.23 to 0.32 at a high recall rate of 0.75 (gain 40%), where a better robustness and confidence were confirmed in the practical experiments.
Ultrasound-guided supraclavicular block: outcome of 510 consecutive cases.
Perlas, Anahi; Lobo, Giovanni; Lo, Nick; Brull, Richard; Chan, Vincent W S; Karkhanis, Reena
2009-01-01
Supraclavicular brachial plexus block provides consistently effective anesthesia to the upper extremity. However, traditional nerve localization techniques may be associated with a high risk of pneumothorax. In the present study, we report block success and clinical outcome data from 510 consecutive patients who received an ultrasound-guided supraclavicular block for upper extremity surgery. After institutional review board approval, the outcome of 510 consecutive patients who received an ultrasound-guided supraclavicular block for upper extremity surgery was reviewed. Real-time ultrasound guidance was used with a high-frequency linear probe. The neurovascular structures were imaged on short axis, and the needle was inserted using an in-plane technique with either a medial-to-lateral or lateral-to-medial orientation. Five hundred ten ultrasound-guided supraclavicular blocks were performed (50 inpatients, 460 outpatients) by 47 different operators at different levels of training over a 24-month period. Successful surgical anesthesia was achieved in 94.6% of patients after a single attempt; 2.8% required local anesthetic supplementation of a single peripheral nerve territory; and 2.6% received an unplanned general anesthetic. No cases of clinically symptomatic pneumothorax developed. Complications included symptomatic hemidiaphragmatic paresis (1%), Horner syndrome (1%), unintended vascular punctures (0.4%), and transient sensory deficits (0.4%). Ultrasound-guided supraclavicular block is associated with a high rate of successful surgical anesthesia and a low rate of complications and thus may be a safe alternative for both inpatients and outpatients. Severe underlying respiratory disease and coagulopathy should remain a contraindication for this brachial plexus approach.
Rha, Dong-wook; Park, Gi-Young; Kim, Yong-Kyun; Kim, Min Tae; Lee, Sang Chul
2013-02-01
To compare the effects of platelet-rich plasma injection with those of dry needling on shoulder pain and function in patients with rotator cuff disease. A single-centre, prospective, randomized, double-blinded, controlled study. University rehabilitation hospital. Thirty-nine patients with a supraspinatus tendon lesion (tendinosis or a partial tear less than 1.0 cm, but not a complete tear) who met the inclusion criteria recruited between June 2010 and February 2011. Two dry needling procedures in the control group and two platelet-rich plasma injections in the experimental group were applied to the affected shoulder at four-week intervals using ultrasound guidance. The Shoulder Pain and Disability Index, passive range of motion of the shoulder, a physician global rating scale at the six-month follow-up, adverse effects monitoring and an ultrasound measurement were used as outcome measures. The clinical effect of the platelet-rich plasma injection was superior to the dry needling from six weeks to six months after initial injection (P < 0.05). At six months the mean Shoulder Pain and Disability Index was 17.7 ± 3.7 in the platelet-rich plasma group versus 29.5 ± 3.8 in the dry needling group (P < 0.05). No severe adverse effects were observed in either group. Autologous platelet-rich plasma injections lead to a progressive reduction in the pain and disability when compared to dry needling. This benefit is certainly still present at six months after treatment. These findings suggest that treatment with platelet-rich plasma injections is safe and useful for rotator cuff disease.
Outcomes of ultrasound guided renal mass biopsies.
Sutherland, Edward L; Choromanska, Agnieszka; Al-Katib, Sayf; Coffey, Mary
2018-06-01
The purpose of this study was to evaluate the rate of nondiagnostic ultrasound-guided renal mass biopsies (RMBs) at our institution and to determine what patient, procedural, and focal renal mass (FRM) factors were associated with nondiagnostic ultrasound-guided RMBs. Eighty-two ultrasound-guided renal mass biopsies performed between January 2014 and October 2016 were included in our study. Biopsy outcomes (diagnostic vs. nondiagnostic) and patient, procedural, and FRM characteristics were retrospectively reviewed and recorded. Univariate statistical analyses were performed to identify biopsy characteristics that were indicative of nondiagnostic biopsy. Ultrasound-guided RMBs were diagnostic in 70 out of 82 cases (85%) and non-diagnostic in 12 cases (15%). Among the diagnostic biopsies, 54 (77%) were malignant cases, 94% of which were renal cell carcinoma (RCC). Of the 12 nondiagnostic cases, the final diagnosis was RCC in 4 cases and angiomyolipoma in one case; seven of the nondiagnostic cases were lost to follow-up. A weak association (p = 0.04) was found between the number of needle passes and the biopsy outcome. None of the remaining collected RMB characteristics showed a significant correlation with a diagnostic or nondiagnostic RMB. Six patients (7%) experienced complications. Ultrasound-guided renal mass biopsy is a safe and effective method for the diagnosis of renal masses with a low rate of nondiagnostic outcomes. A nondiagnostic biopsy should not be treated as a surrogate for a diagnosis since a significant number of patients with nondiagnostic biopsies have subsequently been shown to have renal malignancies. Repeat biopsy should be considered in such cases.
SU-E-J-81: Beveled Needle Tip Detection Error in Ultrasound-Guided Prostate Brachytherapy.
Leu, S; Ruiz, B; Podder, T
2012-06-01
To quantify the needle tip detection errors in ultrasound images due to bevel-tip orientation in relation to the location on template grid. Transrectal ultrasound (TRUS) system (BK Medical) with physical template grid and 18-gauge bevel-tip (20-deg beveled angle) brachytherapy needle (Bard Medical, Covington, GA) were used. The TRUS was set at 6.5MHz in water phantom at 40°C and measurements were taken with 50% and 100% TRUS gains. Needles were oriented with bevel-tip facing up (0-degree) and inserted through template grid-holes. Reference needle depths were measured when needle tip image intensity was bright enough for potentially consistent readings. High-resolution digital vernier caliper was used to measure needle depth. Needle bevel-tip orientation was then changed to bevel down (by rotating 180-degree) and needle depth was adjusted by retracting so that the needle-tip image intensity appeared similar to when the needle bevel-tip was at 0-degree orientation. Clinically relevant locations were considered for needle placement on the template grids (1st row to 9th row, and 'a-f' columns). For 50% TRUS gain, bevel tip detection errors/differences were 0.69±0.30mm (1st row) to 3.23±0.22mm (9th row) and 0.78±0.71mm (1st row) to 4.14±0.56mm (9th row) in columns 'a' and 'D', respectively. The corresponding errors for 100% TRUS gain were 0.57±0.25mm to 5.24±0.36mm and 0.84±0.30mm to 4.2±0.20mm in columns 'a' and 'D', respectively. These errors/differences varied linearly for grid-hole locations on the rows and columns in between, smaller to large depending on distance from the TRUS probe. Observed no effect of gains (50% vs. 100%) along 'D' column, which was directly above the TRUS probe. Experiment results revealed that the beveled needle tip orientation could significantly impact the detection accuracy of the needle tips, based on which the seeds might be delivered. These errors may lead to considerable dosimetric deviations in prostate brachytherapy seed implantation. © 2012 American Association of Physicists in Medicine.
MR guided FUS therapy with a Robotic Assistance System
NASA Astrophysics Data System (ADS)
Jenne, Jürgen W.; Krafft, Axel J.; Maier, Florian; Rauschenberg, Jaane; Semmler, Wolfhard; Huber, Peter E.; Bock, Michael
2009-04-01
Magnetic Resonance imaging guided Focus Ultrasound Surgery (MRgFUS) is a highly precise method to ablate tissue non-invasively. To date, there is only one commercial MRgFUS system available and only a few are in a prototype stage. The objective of this ongoing project is to establish an MRgFUS therapy unit as add-on for a commercially available robotic assistance system originally designed for percutaneous needle interventions in whole-body MR scanners.
A needle guidance system for biopsy and therapy using two-dimensional ultrasound
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bluvol, Nathan; Sheikh, Allison; Kornecki, Anat
2008-02-15
Image-guided needle biopsies are currently used to provide a definitive diagnosis of breast cancer; however, difficulties in tumor targeting exist as the ultrasound (United States) scan plane and biopsy needle must remain coplanar throughout the procedure to display the actual needle tip position. The additional time associated with aligning and maintaining this coplanar relationship results in increased patient discomfort. Biopsy procedural efficiency is further hindered since needle pathway interpretation is often difficult, especially for needle insertions at large depths that usually require multiple reinsertions. The authors developed a system that would increase the speed and accuracy of current breast biopsymore » procedures using readily available two-dimensional (2D) US technology. This system is composed of a passive articulated mechanical arm that attaches to a 2D US transducer. The arm is connected to a computer through custom electronics and software, which were developed as an interface for tracking the positioning of the mechanical components in real time. The arm couples to the biopsy needle and provides visual guidance for the physician performing the procedure in the form of a real-time projected needle pathway overlay on an US image of the breast. An agar test phantom, with stainless steel targets interspersed randomly throughout, was used to validate needle trajectory positioning accuracy. The biopsy needle was guided by both the software and hardware components to the targets. The phantom, with the needle inserted and device decoupled, was placed in an x-ray stereotactic mammography (SM) machine. The needle trajectory and bead target locations were determined in three dimensions from the SM images. Results indicated a mean needle trajectory accuracy error of 0.75{+-}0.42 mm. This is adequate to sample lesions that are <2 mm in diameter. Chicken tissue test phantoms were used to compare core needle biopsy procedure times between experienced radiologists and inexperienced resident radiologists using free-hand US and the needle guidance system. Cylindrical polyvinyl alcohol cryogel lesions, colored blue, were embedded in chicken tissue. Radiologists identified the lesions, visible as hypoechoic masses in the US images, and performed biopsy using a 14-gauge needle. Procedure times were compared based on experience and the technique performed. Using a pair-wise t test, lower biopsy procedure times were observed when using the guidance system versus the free-hand technique (t=12.59, p<0.001). The authors believe that with this improved biopsy guidance they will be able to reduce the ''false negative'' rate of biopsies, especially in the hands of less experienced physicians.« less
2014-01-01
Purpose: This study was designed to determine the rate of ductal carcinoma in situ (DCIS)underestimation diagnosed after an ultrasound-guided 14-gauge core needle biopsy (US-14G-CNB) of breast masses and to compare the clinical and imaging characteristics between trueDCIS and underestimated DCIS identified following surgical excision. Methods: Among 3,124 US-14G-CNBs performed for breast masses, 69 lesions in 60 patients were pathologically-determined to be pure DCIS. We classified these patients according to the final pathology after surgical excision as those with invasive ductal carcinoma (underestimated group) and those with DCIS (non-underestimated group). We retrospectively reviewed and compared the clinical and imaging characteristics between the two groups. Results: Of the 69 lesions, 21 were shown after surgery to be invasive carcinomas; the rateof DCIS underestimation was 30.4%. There were no statistically significant differences withrespect to the clinical symptoms, age, lesion size, mammographic findings, and ultrasonographic findings except for the presence of abnormal axillary lymph nodes as detected on ultrasound. The lesions in 2 patients in the non-underestimated group (2/41, 4.9%) and 5 patients in the underestimated group (5/19, 26.3%) were associated with abnormal lymph nodes on axillary ultrasound, and the presence of abnormal axillary lymph nodes on ultrasound was tatistically significant (P=0.016). Conclusion: We found a 30.4% rate of DCIS underestimation in breast masses based on a US-14G-CNB. The presence of abnormal lymph nodes as detected on axillary ultrasound may be useful to preoperatively predict underestimation. PMID:24936506
Lee, Ban Seok; Cho, Chang-Min; Jung, Min Kyu; Jang, Jung Sik; Bae, Han Ik
2017-07-15
The superiority of endoscopic ultrasound-guided fine needle biopsy (EUS-FNB) over EUS-guided fine needle aspiration (EUS-FNA) remains controversial. Given the lack of studies analyzing histologic specimens acquired from EUS-FNB or EUS-FNA, we compared the proportion of the histologic core obtained from both techniques. A total of 58 consecutive patients with solid mass lesions were enrolled and randomly assigned to the EUS-FNA or EUS-FNB groups. The opposite needle was used after the failure of core tissue acquisition using the initial needle with up to three passes. Using computerized analyses of the scanned histologic slide, the overall area and the area of the histologic core portion in specimens obtained by the two techniques were compared. No significant differences were identified between the two groups with respect to demographic and clinical characteristics. Fewer needle passes were required to obtain core specimens in the FNB group (p<0.001). There were no differences in the proportion of histologic core (11.8%±19.5% vs 8.0%±11.1%, p=0.376) or in the diagnostic accuracy (80.6% vs 81.5%, p=0.935) between two groups. The proportion of histologic core and the diagnostic accuracy were comparable between the FNB and FNA groups. However, fewer needle passes were required to establish an accurate diagnosis in EUS-FNB.
Endoscopic ultrasound-guided techniques for diagnosing pancreatic mass lesions: Can we do better?
Storm, Andrew C; Lee, Linda S
2016-01-01
The diagnostic approach to a possible pancreatic mass lesion relies first upon various non-invasive imaging modalities, including computed tomography, ultrasound, and magnetic resonance imaging techniques. Once a suspect lesion has been identified, tissue acquisition for characterization of the lesion is often paramount in developing an individualized therapeutic approach. Given the high prevalence and mortality associated with pancreatic cancer, an ideal approach to diagnosing pancreatic mass lesions would be safe, highly sensitive, and reproducible across various practice settings. Tools, in addition to radiologic imaging, currently employed in the initial evaluation of a patient with a pancreatic mass lesion include serum tumor markers, endoscopic retrograde cholangiopancreatography, and endoscopic ultrasound-guided fine needle aspiration (EUS-FNA). EUS-FNA has grown to become the gold standard in tissue diagnosis of pancreatic lesions. PMID:27818584
Minimum effective volume of mepivacaine for ultrasound-guided supraclavicular block
Song, Jae Gyok; Kang, Bong Jin; Park, Kee Keun
2013-01-01
Background The aim of this study was to estimate the minimum effective volume (MEV) of 1.5% mepivacaine for ultrasound-guided supraclavicular block by placing the needle near the lower trunk of brachial plexus and multiple injections. Methods Thirty patients undergoing forearm and hand surgery received ultrasound-guided supraclavicular block with 1.5% mepivacaine. The initial volume of local anesthetic injected was 24 ml, and local anesthetic volume for the next patient was determined by the response of the previous patient. The next patient received a 3 ml higher volume in the case of the failure of the previous case. If the previous block was successful, the next volume was 3 ml lower. MEV was estimated by the Dixon and Massey up and down method. MEV in 95, 90, and 50% of patients (MEV95, MEV90, and MEV50) were calculated using probit transformation and logistic regression. Results MEV95 of 1.5% mepivacaine was 17 ml (95% confidence interval [CI], 13-42 ml), MEV90 was 15 ml (95% CI, 12-34 ml), and MEV50 was 9 ml (95% CI, 4-12 ml). Twelve patients had a failed block. Three patients received general anesthesia. Nine patients could undergo surgery with sedation only. Only one patient showed hemi-diaphragmatic paresis. Conclusions MEV95 was 17 ml, MEV90 was 15 ml, and MEV50 was 9 ml. However, needle location near the lower trunk of brachial plexus and multiple injections should be performed. PMID:23904937
Del Cura, Jose Luis; Coronado, Gloria; Zabala, Rosa; Korta, Igone; López, Ignacio
2018-01-31
To review the diagnostic accuracy of ultrasound-guided core-needle biopsy (CNB) in the diagnosis of salivary gland tumours (SGT). Retrospective, institutional review board approved, analysis of the CNB of SGT performed at our centre in 8 years. We used an automatic 18-G spring-loaded device. The final diagnosis was based on surgery in the cases that were operated on, and on clinical evolution and biopsy findings in the rest. Four hundred and nine biopsies were performed in 381 patients (ages, 2-97 years; mean, 55.9). There were two minor complications. Biopsy was diagnostic in 98.3%. There were eight false negatives. The diagnostic values for malignancy were: sensitivity 89.6%, specificity 100%, positive predictive value (PPV) 100% and negative predictive value (NPV) 98%. For the detection of neoplasms were: sensitivity 98.7%, specificity 99%, PPV 99.7% and VPN 96.1%. Accuracy of CNB in SGT is very high, with a very high sensitivity and an absolutely reliable diagnosis of malignancy. Complication rate is very low. It should be considered the technique of choice when a STG is detected. Normal tissue results warrant repeating biopsy. • Ultrasound-guided core-biopsy is the technique of choice in salivary glands nodules • Sensitivity, specificity for detecting neoplasms (which should be resected) are around 99% • Diagnosis of malignancy in core-biopsy is absolutely reliable • A CNB result of "normal tissue", however, warrants repeating the biopsy • Complication rate is very low.
2016-04-01
6 1. INTRODUCTION Lung cancer is the leading cause of cancer related death accounting for more deaths than breast , prostate and colon...the cancer has spread, at which time patients have little chance of cure. Macroscopic imaging modalities including CT and bronchoscopy have made...Electromagnetic Navigation , Biopsy Guidance, Optical Microscopy, Optical Coherence Tomography, Lung Cancer , Optical needle. 3. OVERALL PROJECT SUMMARY
Usawachintachit, Manint; Tzou, David T; Mongan, John; Taguchi, Kazumi; Weinstein, Stefanie; Chi, Thomas
2017-02-01
Ultrasound-guided percutaneous nephrolithotomy (PCNL) has become increasingly utilized. Patients with nondilated collecting systems represent a challenge: the target calix is often difficult to visualize. Here we report pilot study results for retrograde ultrasound contrast injection to aid in percutaneous renal access during ultrasound-guided PCNL. From April to July 2016, consecutive patients over the age of 18 years with nondilated collecting systems on preoperative imaging who presented for PCNL were enrolled. B-mode ultrasound imaging was compared with contrast-enhanced mode with simultaneous retrograde injection of Optison™ via an ipsilateral ureteral catheter. Five patients (four males and one female) with renal stones underwent PCNL with retrograde ultrasound contrast injection during the study period. Mean body mass index was 28.3 ± 5.6 kg/m 2 and mean stone size was 24.5 ± 12.0 mm. Under B-mode ultrasound, all patients demonstrated nondilated renal collecting systems that appeared as hyperechoic areas, where it was difficult to identify a target calix for puncture. Retrograde contrast injection facilitated delineation of all renal calices initially difficult to visualize under B-mode ultrasound. Renal puncture was then performed effectively in all cases with a mean puncture time of 55.4 ± 44.8 seconds. All PCNL procedures were completed without intraoperative complications and no adverse events related to ultrasound contrast injection occurred. Retrograde ultrasound contrast injection as an aide for renal puncture during PCNL is a feasible technique. By improving visualization of the collecting system, it facilitates needle placement in challenging patients without hydronephrosis. Future larger scale studies comparing its use to standard ultrasound-guided technique will be required to validate this concept.
Valera-Garrido, Fermín; Minaya-Muñoz, Francisco; Medina-Mirapeix, Francesc
2014-01-01
Background Ultrasound (US)-guided percutaneous needle electrolysis (PNE) is a novel minimally invasive approach which consists of the application of a galvanic current through an acupuncture needle. Objective To evaluate the clinical and ultrasonographic effectiveness of a multimodal programme (PNE, eccentric exercise (EccEx) and stretching) in the short term for patients with chronic lateral epicondylitis, and to determine whether the clinical outcomes achieved decline over time. Methods A one-way repeated measures study was performed in a clinical setting in 36 patients presenting with lateral epicondylitis. The patients received one session of US-guided PNE per week over 4–6 weeks, associated with a home programme of EccEx and stretching. The main outcome measures were severity of pain, disability (Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire), structural tendon changes (US), hypervascularity and patients’ perceptions of overall outcome. Measurements at 6, 26 and 52 weeks follow-up included recurrence rates (increase in severity of pain or disability compared with discharge), perception of overall outcome and success rates. Results All outcome measures registered significant improvements between pre-intervention and discharge. Most patients (n=30, 83.3%) rated the overall outcome as ‘successful’ at 6 weeks. The ultrasonographic findings showed that the hypoechoic regions and hypervascularity of the extensor carpi radialis brevis changed significantly. At 26 and 52 weeks, all participants (n=32) perceived a ‘successful’ outcome. Recurrence rates were null after discharge and at follow-up at 6, 26 and 52 weeks. Conclusions Symptoms and degenerative structural changes of chronic lateral epicondylitis are reduced after US-guided PNE associated with EccEx and stretching, with encouragingly low recurrences in the mid to long term. Trial registration number ClinicalTrials.gov identifier: NCT02085928. PMID:25122629
Comparison of incision and drainage against needle aspiration for the treatment of breast abscess.
Naeem, Muhammad; Rahimnajjad, Muhammad Kazim; Rahimnajjad, Nasir Ali; Ahmed, Qazi Jalaluddin; Fazel, Pyar Ali; Owais, Muhammad
2012-11-01
We aim to compare the incision and drainage against ultrasound-guided aspiration for the treatment of breast abscesses. Sixty-four patients were randomly allocated to Group A (incision and drainage) and Group B (needle aspiration). Incision and drainage was done under general, whereas aspiration was done under local anesthesia with antibiotic coverage after the pus sample was taken for cultures. Time taken to resolve symptoms including point tenderness, erythema and hyperthermia, recurrence of breast abscess, and healing time was recorded. Patients were followed until 8 weeks. Culture and sensitivity of the pus were done. Data were analyzed in SPSS 16.0. The mean difference of healing time was significant (P = 0.001). A total of 93.3 per cent were healed in Group B and 76.6 per cent in Group A (P = 0.033). Twenty-two samples (34.37%) had no bacterial yield and the remaining 42 samples (65.6%) yielded 11 anaerobic cultures (17.18%) and 31 aerobic cultures (48.4%). Ultrasound-guided aspiration of breast abscesses with the judicious use of antibiotics is a better treatment modality than incision and drainage.
Wang, David; Amesur, Nikhil; Shukla, Gaurav; Bayless, Angela; Weiser, David; Scharl, Adam; Mockel, Derek; Banks, Christopher; Mandella, Bernadette; Klatzky, Roberta; Stetten, George
2010-01-01
Objective We describe a case series comprising the first clinical trial by intravenous (IV) team nurses using the Sonic Flashlight for ultrasound guidance of peripherally inserted central catheter (PICC) placement. Methods Two IV team nurses with more than 10 years experience placing PICCs and from 3–6 years experience with ultrasound (US) attempted to place PICCs under US guidance in patients requiring long-term IV access. One of two methods of US guidance was used: conventional ultrasound (CUS) (60 patients) or a new device called the Sonic Flashlight (SF) (44 patients). The number of needle punctures required to gain IV access was recorded for each subject. Results In both methods, 87% of the cases resulted in successful venous access on the first attempt. The average number of needle sticks per patient was 1.18 for SF-guided procedures, as compared to 1.20 for CUS-guided procedures. No significant difference was found in the distribution of the number of attempts between the two methods. Anecdotal comments by the nurses indicated the comparative ease of use of the SF display, although relatively small scale of the SF image compared to the CUS image was also noted. Conclusions We have shown that the Sonic Flashlight is a safe and effective device for guidance of PICC placement in the hands of experienced IV team nurses. The advantage of placing the ultrasound image at its actual location must be balanced against the relatively small scale of the SF image. PMID:19389904
Penthrox inhaler analgesia in transrectal ultrasound-guided prostate biopsy.
Lee, Chanyang; Woo, Henry H
2015-06-01
Periprostatic injection of local anaesthetic (PILA) has been shown to significantly reduce pain in patients undergoing transrectal ultrasound-guided prostate biopsy (TRUSPB). However, this method does not address pain that is associated with ultrasound probe insertion, and the injection of local anaesthetic itself causes pain. The aim of this study was to explore the efficacy of methoxyflurane delivered by a Penthrox inhaler as a novel method of pain relief during TRUSPB. From July 2012 to July 2013, 64 patients were scheduled at a single centre to undergo TRUSPB while receiving analgesia via Penthrox inhaler. Fifteen minutes after the biopsy procedure, these patients were asked to complete a pain score survey using a 10-cm visual analogue scale (VAS) to separately report the degree of pain experienced during digital rectal examination (DRE), ultrasound probe insertion and core biopsy. The median pain scores on a 10-cm VAS were 2.0, 2.4 and 3.0 during DRE, probe insertion and needle biopsy, respectively, while using the Penthrox inhaler. Of the 64 patients, 11 had undergone TRUSPB previously receiving PILA. In these patients, PILA was significantly better than the Penthrox inhaler for pain relief during needle biopsy (median pain score 2.0 versus 4.0; P = 0.012). The Penthrox inhaler appears to be a safe and effective method of analgesia for TRUSPB. Patients who had experienced both PILA and Penthrox reported pain scores that significantly favoured PILA over the Penthrox inhaler. © 2014 Royal Australasian College of Surgeons.
Sinskey, Jina L; Vecchione, Tricia M; Ekstrom, Benjamin G; Boretsky, Karen
2018-06-01
Pediatric caudal epidural blockade, the most common pediatric regional anesthetic, is classically placed using surface landmark technique with infrequent use of ultrasound guidance. We present 3 cases where ultrasound guidance facilitated successful placement and helped prevent complications. One infant had an unanticipated S5 dural sac necessitating needle redirection to avoid subarachnoid injection. A 5-year old had proper needle position with inability to inject secondary to needle blockage confirmed with ultrasound. An expremature infant had initial needle placement anterior to the sacrum with subsequent proper placement using real-time ultrasound imaging. Ultrasound guidance for pediatric caudal placement confers advantages and increased routine use should be considered.
Development of a Novel Ultrasound-guided Peritonsillar Abscess Model for Simulation Training.
Ng, Vivienne; Plitt, Jennifer; Biffar, David
2018-01-01
Peritonsillar abscess (PTA) is the most common deep space infection of the head and neck presenting to emergency departments.1 No commercial PTA task trainer exists for simulation training. Thus, resident physicians often perform their first PTA needle aspiration in the clinical setting, knowing that carotid artery puncture and hemorrhage are serious and devastating complications. While several low-fidelity PTA task trainers have been previously described, none allow for ultrasound image acquisition.6-9 We sought to create a cost-effective and realistic task trainer that allows trainees to acquire both diagnostic ultrasound and needle aspiration skills while draining a peritonsillar abscess. We built the task trainer with low-cost, replaceable, and easily cleanable materials. A damaged airway headskin was repurposed to build the model. A mesh wire cylinder attached to a wooden base was fashioned to provide infrastructure. PTAs were simulated with a water and lotion solution inside a water balloon that was glued to the bottom of a paper cup. The balloon was fully submerged with ordnance gelatin to facilitate ultrasound image acquisition, and an asymmetric soft palate and deviated uvula were painted on top after setting. PTA cups were replaced after use. We spent eight hours constructing three task trainers and used 50 PTA cups for a total cost <$110. Forty-six emergency medicine (EM) residents performed PTA needle aspirations using the task trainers and were asked to rate ultrasound image realism, task trainer realism, and trainer ease of use on a five-point visual analog scale, with five being very realistic and easy. Sixteen of 46 (35%) residents completed the survey and reported that ultrasound images were representative of real PTAs (mean 3.41). They found the model realistic (mean 3.73) and easy to use (mean 4.08). Residents rated their comfort with the drainage procedure as 2.07 before and 3.64 after practicing on the trainer. This low-cost, easy-to-construct simulator allows for ultrasound image acquisition while performing PTA needle aspirations and is the first reported of its kind. Educators from EM and otolaryngology can use this model to educate inexperienced trainees, thus ultimately improving patient safety in the clinical setting.
Is ultrasound-guided injection more effective in chronic subacromial bursitis?
Hsieh, Lin-Fen; Hsu, Wei-Chun; Lin, Yi-Jia; Wu, Shih-Hui; Chang, Kae-Chwen; Chang, Hsiao-Lan
2013-12-01
Although ultrasound (US)-guided subacromial injection has shown increased accuracy in needle placement, whether US-guided injection produces better clinical outcome is still controversial. Therefore, this study aimed to compare the efficacy of subacromial corticosteroid injection under US guidance with palpation-guided subacromial injection in patients with chronic subacromial bursitis. Patients with chronic subacromial bursitis were randomized to a US-guided injection group and a palpation-guided injection group. The subjects in each group were injected with a mixture of 0.5 mL dexamethasone suspension and 3 mL lidocaine into the subacromial bursa. The primary outcome measures were the visual analog scale for pain and active and passive ranges of motion of the affected shoulder. Secondary outcome measures were the Shoulder Pain and Disability Index, the Shoulder Disability Questionnaire, and the 36-item Short-Form Health Survey (SF-36). The primary outcome measures were evaluated before, immediately, 1 wk, and 1 month after the injection; the secondary outcome measures were evaluated before, 1 wk, and 1 month after the injection. Of the 145 subjects screened, 46 in each group completed the study. Significantly greater improvement in passive shoulder abduction and in physical functioning and vitality scores on the SF-36 were observed in the US-guided group. The pre- and postinjection within-group comparison revealed significant improvement in the visual analog scale for pain and range of motion, as well as in the Shoulder Pain and Disability Index, Shoulder Disability Questionnaire, and SF-36 scores, in both groups. The US-guided subacromial injection technique produced significantly greater improvements in passive shoulder abduction and in some items of the SF-36. US is effective in guiding the needle into the subacromial bursa in patients with chronic subacromial bursitis.
Robotic active positioning for magnetic resonance-guided high-intensity focused ultrasound
NASA Astrophysics Data System (ADS)
Xiao, Xu; Huang, Zhihong; Volovick, Alexander; Melzer, Andreas
2012-11-01
Magnetic resonance (MR) guided High-intensity focused ultrasound (HIFU) is a noninvasive method producing thermal necrosis and cavitation at the position of tumors with high accuracy. Because the typical size of the high-intensity focused ultrasound focus are much smaller than the targeted tumor or other tissues, multiple sonications and focus repositioning become necessary for HIFU treatment. In order to reach a much wider range, manual repositioning or using MR compatible mechanical actuators could be used. The repositioning technique is a time consuming procedure because it needs a series of MR imaging to detect the transducer and markers preplaced on the mechanical devices. We combined an active tracking technique into the MR guided HIFU system. In this work, the robotic system used is the MR-compatible robotics from InnoMotion{trade mark, serif} (IBSMM, Engineering spol. s r.o. / Ltd, Czech) which is originally designed for MR-guided needle biopsy. The precision and positioning speed of the combined robotic HIFU system are evaluated in this study. Compared to the existing MR guided HIFU systems, the combined robotic system with active tracking techniques provides a potential that allows the HIFU treatment to operate in a larger spatial range and with a faster speed.
A training phantom for ultrasound-guided needle insertion and suturing.
Nattagh, Khashayar; Siauw, Timmy; Pouliot, Jean; Hsu, I-Chow; Cunha, J Adam
2014-01-01
During gynecologic brachytherapy (BT), suturing and image-guided needle insertions are highly skill-dependent tasks. Medical residents often have to practice these techniques in the operating room; this is sub-optimal for many reasons. We present a fast and low-cost method of building realistic and disposable gynecologic phantoms, which can be used to train physicians new to gynecologic BT. Phantoms comprised a rectal cavity large enough to accommodate a standard transrectal ultrasound (US) probe, a vaginal cavity, a uterus, a uterine canal, and a cervix, all embedded in a gelatin matrix. The uterus was made of gelatin and coated with rubber to mimic the texture of soft tissue and for computed tomography (CT) and US image contrast. The phantom's durability, longevity, construction times, materials costs, CT, and US image quality were recorded. The speed of sound in the gelatin was measured using pulse echo measurements. Anatomic structures were distinguishable using CT and US. For the first phantom, material costs were under $200, curing time was approximately 48 hours, and active participation time was 3 hours. Reusable parts allowed for reduction in time and cost for subsequent phantoms: under $20, 24 hours curing time, and 1 hour active participation time. The speed of sound in the gelatin ranged from 1495 to 1506 m/s. A method for constructing gelatin gynecologic phantoms was developed. It can be used for training in image-guided BT needle insertion, placing a suture on the vaginal wall, and suturing the cervical lip. Copyright © 2014 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
Endoscopic Ultrasound-Guided Fine Needle Aspiration: From the Past to the Future
Costache, Mădălin-Ionuț; Iordache, Sevastița; Karstensen, John Gásdal; Săftoiu, Adrian; Vilmann, Peter
2013-01-01
Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) is a technique which allows the study of cells obtained through aspiration in different locations near the gastrointestinal tract. EUS-FNA is used to acquire tissue from mucosal/submucosal tumors, as well as peri-intestinal structures including lymph nodes, pancreas, adrenal gland, gallbladder, bile duct, liver, kidney, lung, etc. The pancreas and lymph nodes are still the most common organs targeted in EUS-FNA. The overall accuracy of EUS is superior to computed tomography scan and magnetic resonance imaging for detecting pancreatic lesions. In most cases it is possible to avoid unnecessary surgical interventions in advanced pancreatic cancer, and EUS is considered the preferred method for loco-regional staging of pancreatic cancer. FNA improved the sensitivity and specificity compared to EUS imaging alone in detection of malignant lymph nodes. The negative predictive value of EUS-FNA is relatively low. The presence of a cytopathologist during EUS-FNA improves the diagnostic yield, decreasing unsatisfactory samples or need for additional passes, and consequently the procedural time. The size of the needle is another factor that could modify the diagnostic accuracy of EUS-FNA. Even though the EUS-FNA technique started in early nineteen's, there are many remarkable progresses culminating nowadays with the discovery and performance of needle-based confocal laser endomicroscopy. Last, but not least, identification and quantification of potential molecular markers for pancreatic cancer on cellular samples obtained by EUS-FNA could be a promising approach for the diagnosis of solid pancreatic masses. PMID:24949369
Kaseda, Kaoru; Asakura, Keisuke; Kazama, Akio; Ozawa, Yukihiko
2016-12-01
Lymph nodes in patients with non-small cell lung cancer (NSCLC) are often staged using integrated 18F-fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT). However, this modality has limited ability to detect micrometastases. We aimed to define risk factors for occult lymph node metastasis in patients with clinical stage I NSCLC diagnosed by preoperative integrated FDG-PET/CT. We retrospectively reviewed the records of 246 patients diagnosed with clinical stage I NSCLC based on integrated FDG-PET/CT between April 2007 and May 2015. All patients were treated by complete surgical resection. The prevalence of occult lymph node metastasis in patients with clinical stage I NSCLC was analysed according to clinicopathological factors. Risk factors for occult lymph node metastasis were defined using univariate and multivariate analyses. Occult lymph node metastasis was detected in 31 patients (12.6 %). Univariate analysis revealed CEA (P = 0.04), SUV max of the primary tumour (P = 0.031), adenocarcinoma (P = 0.023), tumour size (P = 0.002) and pleural invasion (P = 0.046) as significant predictors of occult lymph node metastasis. Multivariate analysis selected SUV max of the primary tumour (P = 0.049), adenocarcinoma (P = 0.003) and tumour size (P = 0.019) as independent predictors of occult lymph node metastasis. The SUV max of the primary tumour, adenocarcinoma and tumour size were risk factors for occult lymph node metastasis in patients with NSCLC diagnosed as clinical stage I by preoperative integrated FDG-PET/CT. These findings would be helpful in selecting candidates for mediastinoscopy or endobronchial ultrasound-guided transbronchial needle aspiration.
The value of rapid on-site evaluation during EBUS-TBNA.
Cardoso, A V; Neves, I; Magalhães, A; Sucena, M; Barroca, H; Fernandes, G
2015-01-01
Rapid on-site evaluation (ROSE) has the potential to increase endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) accuracy in the diagnosis of mediastinal lesions and lung cancer staging. However, studies have reported controversial results. The purpose of our study was to evaluate the influence of ROSE on sample adequacy and diagnostic accuracy of EBUS-TBNA. Prospective observational study that enrolled 81 patients who underwent EBUS-TBNA for investigation of hilo-mediastinal lesions or lung cancer staging. The first 41 patients underwent EBUS-TBNA with ROSE (ROSE group) and the last 40 patients without ROSE (non-ROSE group). Sample adequacy and diagnostic accuracy of EBUS-TBNA in both groups were compared. Adequate samples were obtained in 93% of the patients in the ROSE group and 80% in non-ROSE group (p=0.10). The diagnostic accuracy of EBUS-TBNA was 91% in ROSE group and 83% in non-ROSE group (p=0.08). Analyzing the EBUS-TBNA purpose, in the subgroup of patients who underwent EBUS-TBNA for investigation of hilo-mediastinal lesions, these differences between ROSE and non-ROSE group were higher compared to lung cancer staging, 93% of patients with adequate samples in the ROSE group vs. 75% in the non-ROSE group (p=0.06) and 87% of diagnostic accuracy in ROSE group vs. 77% in non-ROSE group (p=0.10). Despite the lack of statistical significance, ROSE appears to be particularly useful in the diagnostic work-up of hilo-mediastinal lesions, increasing the diagnostic yield of EBUS-TBNA. Copyright © 2014 Sociedade Portuguesa de Pneumologia. Published by Elsevier España, S.L.U. All rights reserved.
The Ultrasound-Guided Retroclavicular Block: A Prospective Feasibility Study.
Charbonneau, Jasmin; Fréchette, Yannick; Sansoucy, Yanick; Echave, Pablo
2015-01-01
The aim of this feasibility study was to determine the success rate (sensory and surgical) of the novel retroclavicular block and to thoroughly describe the technique. In addition, needle tip and shaft visibility, needling time, procedural discomfort, motor block success rate, patient satisfaction at 48-hour follow-up, and complications were also recorded. Fifty patients scheduled for distal upper limb surgery received an in-plane, single-shot, ultrasound-guided retroclavicular block with 40 mL of mepivacaine 1.5% with epinephrine 2.5 μg/mL. Block success was defined as a sensory score of 10/10 for the 5 nerves supplying the distal upper limb at 30 minutes. Surgical success, needle visibility, needling time, axillary artery depth, motor block rate, patient discomfort with technique, satisfaction at 48 hours, and complications were also recorded. All blocks were video-recorded and timed for further independent assessment. A chest x-ray was obtained before discharge. Forty-five patients had a total sensory score of 10/10 at 30 minutes (90% success rate). Surgical success rate was 96%. Mean needling time was 3.77 minutes (25th-75th percentiles, 2.90-6.53 minutes) with a mean axillary artery depth of 3.1 ± 0.7 cm. Procedure-related discomfort (mean visual analog scale, 1.9 ± 1.2) was low. Mean 48-hour patient satisfaction rate (9.2 ± 1.1), mean needle tip (Likert scale, 3.0 ± 0.9), and shaft visibility (3.9 ± 0.9) were high. One vascular puncture and two transient paresthesias were recorded. No pneumothorax was revealed by chest x-ray. In this study, the novel retroclavicular block offered a quick, safe, and reliable alternative for distal arm block. Further studies, comparing this approach with the classic infraclavicular block, are required to validate its efficacy, safety, and reliability.
Rajpal, Gaurav; Winger, Daniel G; Cortazzo, Megan; Kentor, Michael L; Orebaugh, Steven L
2016-01-01
Postoperative neurologic symptoms after interscalene block and shoulder surgery have been reported to be relatively frequent. Reports of such symptoms after ultrasound-guided block have been variable. We evaluated 300 patients for neurologic symptoms after low-volume, ultrasound-guided interscalene block and arthroscopic shoulder surgery. Patients underwent ultrasound-guided interscalene block with 16 to 20 mL of 0.5% bupivacaine or a mix of 0.2% bupivacaine/1.2% mepivacaine solution, followed by propofol/ketamine sedation for ambulatory arthroscopic shoulder surgery. Patients were called at 10 days for evaluation of neurologic symptoms, and those with persistent symptoms were called again at 30 days, at which point neurologic evaluation was initiated. Details of patient demographics and block characteristics were collected to assess any association with persistent neurologic symptoms. Six of 300 patients reported symptoms at 10 days (2%), with one of these patients having persistent symptoms at 30 days (0.3%). This was significantly lower than rates of neurologic symptoms reported in preultrasound investigations with focused neurologic follow-up and similar to other studies performed in the ultrasound era. There was a modest correlation between the number of needle redirections during the block procedure and the presence of postoperative neurologic symptoms. Ultrasound guidance of interscalene block with 16- to 20-mL volumes of local anesthetic solution results in a lower frequency of postoperative neurologic symptoms at 10 and 30 days as compared with investigations in the preultrasound period.
Kedia, Prashant; Gaidhane, Monica
2013-01-01
Endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) is one of the least invasive and most effective modality in diagnosing pancreatic adenocarcinoma in solid pancreatic lesions, with a higher diagnostic accuracy than cystic tumors. EUS-FNA has been shown to detect tumors less than 3 mm, due to high spatial resolution allowing the detection of very small lesions and vascular invasion, particularly in the pancreatic head and neck, which may not be detected on transverse computed tomography. Furthermore, this minimally invasive procedure is often ideal in the endoscopic procurement of tissue in patients with unresectable tumors. While EUS-FNA has been increasingly used as a diagnostic tool, most studies have collectively looked at all primary pancreatic solid lesions, including lymphomas and pancreatic neuroendocrine neoplasms, whereas very few studies have examined the diagnostic utility of EUS-FNA of pancreatic ductal carcinoma only. As with any novel and advanced endoscopic procedure that may incorporate several practices and approaches, endoscopists have adopted diverse techniques to improve the tissue procurement practice and increase diagnostic accuracy. In this article, we present a review of literature to date and discuss currently practiced EUS-FNA technique, including indications, technical details, equipment, patient selection, and diagnostic accuracy. PMID:24143320
Lanza, Ezio; Banfi, Giuseppe; Serafini, Giovanni; Lacelli, Francesca; Orlandi, Davide; Bandirali, Michele; Sardanelli, Francesco; Sconfienza, Luca Maria
2015-07-01
We performed a systematic review of current evidence regarding ultrasound-guided percutaneous irrigation of calcific tendinopathy (US-PICT) in the shoulder aimed to: assess different published techniques; evaluate clinical outcome in a large combined cohort; and propose suggestions for homogeneous future reporting. Cochrane Collaboration for Systematic Reviews of Interventions Guidelines were followed. We searched MEDLINE/MEDLINE In-Process/EMBASE/Cochrane databases from 1992-2013 using the keywords 'ultrasound, shoulder, needling, calcification, lavage, rotator cuff' combined in appropriate algorithms. References of resulting papers were also screened. Risk of bias was assessed with a modified Newcastle-Ottawa Scale. Of 284 papers found, 15 were included, treating 1,450 shoulders in 1,403 patients (females, n = 838; mean age interval 40-63 years). There was no exclusion due to risk of bias. US-PICT of rotator cuff is a safe and effective procedure, with an estimated average 55% pain improvement at an average of 11 months, with a 10% minor complication rate. No evidence exists in favour of using a specific size/number of needles. Imaging follow-up should not be used routinely. Future studies should aim at structural uniformity, including the use of the Constant Score to assess outcomes and 1-year minimum follow-up. Alternatives to steroid injections should also be explored. • US-PICT of rotator cuff is a safe and effective procedure. • On average 55% pain improvement with 10% minor complication rate. • No evidence exists in favour of using a specific size/number of needles. • Future need to assess outcome using Constant Score with 1-year minimum follow-up.
Chagas-Neto, Francisco A; Taneja, Atul K; Gregio-Junior, Everaldo; Nogueira-Barbosa, Marcello H
2017-06-01
This study aims to describe a technique for in-plane ultrasound-guided knee arthrography through a lateral suprapatellar approach, reporting its accuracy and related complications. A retrospective search was performed for computed tomography and magnetic resonance reports from June 2013 through June 2015. Imaging studies, puncture descriptions, and guided-procedure images were reviewed along with clinical and surgical history. A fellowship-trained musculoskeletal radiologist performed all procedures under sterile technique and ultrasound guidance with the probe in oblique position on the lateral suprapatellar recess after local anesthesia with the patient on dorsal decubitus, hip in neutral rotation, and 30 to 45 degrees of knee flexion. A total of 86 consecutive subjects were evaluated (mean, 55 years). All subjects underwent intra-articular injection of contrast, which was successfully reached in the first attempt in 94.2% of the procedures (81/86), and in the second attempt in 5.8% (5/86) after needle repositioning without a second puncture. There were no postprocedural reports of regional complications at the puncture site, such as significant pain, bleeding, or vascular lesions. Our study demonstrates that in-plane ultrasound-guided injection of the knee in semiflexion approaching the lateral suprapatellar recess is a safe and useful technique to administer intra-articular contrast solution, as an alternative method without radiation exposure.
High-frequency ultrasound imaging for breast cancer biopsy guidance
Cummins, Thomas; Yoon, Changhan; Choi, Hojong; Eliahoo, Payam; Kim, Hyung Ham; Yamashita, Mary W.; Hovanessian-Larsen, Linda J.; Lang, Julie E.; Sener, Stephen F.; Vallone, John; Martin, Sue E.; Kirk Shung, K.
2015-01-01
Abstract. Image-guided core needle biopsy is the current gold standard for breast cancer diagnosis. Microcalcifications, an important radiographic finding on mammography suggestive of early breast cancer such as ductal carcinoma in situ, are usually biopsied under stereotactic guidance. This procedure, however, is uncomfortable for patients and requires the use of ionizing radiation. It would be preferable to biopsy microcalcifications under ultrasound guidance since it is a faster procedure, more comfortable for the patient, and requires no radiation. However, microcalcifications cannot reliably be detected with the current standard ultrasound imaging systems. This study is motivated by the clinical need for real-time high-resolution ultrasound imaging of microcalcifications, so that biopsies can be accurately performed under ultrasound guidance. We have investigated how high-frequency ultrasound imaging can enable visualization of microstructures in ex vivo breast tissue biopsy samples. We generated B-mode images of breast tissue and applied the Nakagami filtering technique to help refine image output so that microcalcifications could be better assessed during ultrasound-guided core biopsies. We describe the preliminary clinical results of high-frequency ultrasound imaging of ex vivo breast biopsy tissue with microcalcifications and without Nakagami filtering and the correlation of these images with the pathology examination by hematoxylin and eosin stain and whole slide digital scanning. PMID:26693167
Wang, Jinlin; Zhou, Xinghua; Xie, Xiaohong; Tang, Qing; Shen, Panxiao; Zeng, Yunxiang
2016-11-17
The most efficient approach to diagnose malignant pleural effusions (MPEs) is still controversial and uncertain. This study aimed to evaluate the utility of a combined approach using ultrasound (US)-guided cutting-needle biopsy (CNB) and standard pleural biopsy (SPB) for diagnosing MPE. Pleural effusions were collected from 172 patients for biochemical and microbiological analyses. US-guided CNB and SPB were performed in the same operation sequentially to obtain specimens for histological analysis. US-guided CNB and SPB procedures provided adequate material for histological analysis in 90.7 and 93.0% of cases, respectively, while a combination of the 2 techniques was in 96.5% of cases. The sensitivity, specificity, positive-predictive value (PPV), negative-predictive value (NPV) and diagnostic accuracy of US-guided CNB versus SPB were: 51.2 vs 63.4%, 100 vs 100%, 100 vs 100%, 64.9 vs 72.2% and 74.4 vs 81.3%, respectively. When CNB was combined with SPB, the corresponding values were 88.6, 100, 100, 88.6 and 93.9%, respectively. Whereas sensitivity, NPV and diagnostic accuracy were not significantly different between CNB and SPB, the combination of CNB and SPB significantly improved the sensitivity, NPV and diagnostic accuracy versus each technique alone (p < 0.05). Significant pain (eight patients), moderate haemoptysis (two patients) and chest wall haematomas (two patients) were observed following CNB, while syncope (four patients) and a slight pneumothorax (four patients) were observed following SPB. Use of a combination of US-guided CNB and SPB afforded a high sensitivity to diagnose MPEs, it is a convenient and safe approach.
Musculoskeletal ultrasound for interventional physiatry.
De Muynck, M; Parlevliet, T; De Cock, K; Vanden Bossche, L; Vanderstraeten, G; Özçakar, L
2012-12-01
More and more physiatrists are interested in learning how to use musculoskeletal ultrasonography in their clinical practice. The possibility of high resolution, dynamic, comparative and repeatable imaging makes it an important diagnostic tool for soft tissue pathology. There is also growing interest to use sonography for guiding interventions such as aspirations and infiltrations. In daily practice these are often done blindly or palpation-guided. To improve the accuracy of interventions, fluoroscopy or computed tomography were traditionally used for guidance. Since sonography is non-ionizing, readily available and relatively low cost, it has become the first choice to guide many musculoskeletal interventions. Ultrasound allows real-time imaging of target and needle as well as surrounding vulnerable structures such as vessels and nerves. Many different techniques are proposed in the literature. Interventions under ultrasound guidance have been proven to be more accurate than unguided ones. Further studies are required to prove better clinical results and fewer complications. Infection is the most dreaded complication. This review wants to highlight technical aspects of ultrasound guidance of interventions and give a survey of different interventions that have been introduced, with emphasis on applications in Physical Medicine and Rehabilitation. Results and complications are discussed. Finally training requirements and modalities are presented.
Segmentation of prostate biopsy needles in transrectal ultrasound images
NASA Astrophysics Data System (ADS)
Krefting, Dagmar; Haupt, Barbara; Tolxdorff, Thomas; Kempkensteffen, Carsten; Miller, Kurt
2007-03-01
Prostate cancer is the most common cancer in men. Tissue extraction at different locations (biopsy) is the gold-standard for diagnosis of prostate cancer. These biopsies are commonly guided by transrectal ultrasound imaging (TRUS). Exact location of the extracted tissue within the gland is desired for more specific diagnosis and provides better therapy planning. While the orientation and the position of the needle within clinical TRUS image are limited, the appearing length and visibility of the needle varies strongly. Marker lines are present and tissue inhomogeneities and deflection artefacts may appear. Simple intensity, gradient oder edge-detecting based segmentation methods fail. Therefore a multivariate statistical classificator is implemented. The independent feature model is built by supervised learning using a set of manually segmented needles. The feature space is spanned by common binary object features as size and eccentricity as well as imaging-system dependent features like distance and orientation relative to the marker line. The object extraction is done by multi-step binarization of the region of interest. The ROI is automatically determined at the beginning of the segmentation and marker lines are removed from the images. The segmentation itself is realized by scale-invariant classification using maximum likelihood estimation and Mahalanobis distance as discriminator. The technique presented here could be successfully applied in 94% of 1835 TRUS images from 30 tissue extractions. It provides a robust method for biopsy needle localization in clinical prostate biopsy TRUS images.
Johnson, S J; Hunt, C M; Woolnough, H M; Crawshaw, M; Kilkenny, C; Gould, D A; England, A; Sinha, A; Villard, P F
2012-05-01
The aim of this article was to identify and prospectively investigate simulated ultrasound-guided targeted liver biopsy performance metrics as differentiators between levels of expertise in interventional radiology. Task analysis produced detailed procedural step documentation allowing identification of critical procedure steps and performance metrics for use in a virtual reality ultrasound-guided targeted liver biopsy procedure. Consultant (n=14; male=11, female=3) and trainee (n=26; male=19, female=7) scores on the performance metrics were compared. Ethical approval was granted by the Liverpool Research Ethics Committee (UK). Independent t-tests and analysis of variance (ANOVA) investigated differences between groups. Independent t-tests revealed significant differences between trainees and consultants on three performance metrics: targeting, p=0.018, t=-2.487 (-2.040 to -0.207); probe usage time, p = 0.040, t=2.132 (11.064 to 427.983); mean needle length in beam, p=0.029, t=-2.272 (-0.028 to -0.002). ANOVA reported significant differences across years of experience (0-1, 1-2, 3+ years) on seven performance metrics: no-go area touched, p=0.012; targeting, p=0.025; length of session, p=0.024; probe usage time, p=0.025; total needle distance moved, p=0.038; number of skin contacts, p<0.001; total time in no-go area, p=0.008. More experienced participants consistently received better performance scores on all 19 performance metrics. It is possible to measure and monitor performance using simulation, with performance metrics providing feedback on skill level and differentiating levels of expertise. However, a transfer of training study is required.
Endoscopic ultrasound-guided transesophageal thoracentesis for minimal pleural effusion.
Rana, Surinder Singh; Sharma, Ravi; Gupta, Rajesh
2018-06-19
Pleural effusion is a common finding both in patients with benign and malignant diseases of pleura and lung with diagnostic thoracentesis establishing the diagnosis in the majority of cases. The diagnostic thoracentesis can be done either blindly or under the guidance of ultrasound or computed tomography. However, minimal pleural effusion is difficult to sample even under image guidance. Endoscopic ultrasound (EUS) is known to detect smaller volume of pleural effusion and, thus, can help in guiding thoracentesis. To analyze the safety and efficacy of EUS-guided diagnostic thoracentesis in patients with undiagnosed minimal pleural effusion retrospectively. Retrospective analysis of the data of patients with minimal pleural effusion, who underwent EUS-guided transesophageal diagnostic thoracentesis over last 2 years, was performed. Thirteen patients (11 male; mean age 46.7 ± 16.2 years) with undiagnosed minimal pleural effusion underwent successful EUS-guided transesophageal diagnostic thoracentesis using a 22-G needle. Seven (53%) patients had fever on presentation whereas two presented with cough and loss of appetite. Eight to 54 mL fluid was aspirated with an attempt to completely empty the pleural cavity. There were no complications of the procedure. EUS-guided diagnostic thoracentesis is a safe and effective alternative for evaluating patients with minimal pleural effusion.
Sites, Brian D; Antonakakis, John G
2009-01-01
Ultrasound guided regional anesthesia (UGRA) for peripheral nerve blockade is becoming increasingly popular. The advantage of ultrasound technology is that it affords the anesthesiologist the real time ability to visualize neural structures, needle advancement, and local anesthetic spread. Recent data suggest that UGRA generates improved success rates and reductions in performance times in comparison to traditional approaches. Further, the use of ultrasound technology in peripheral nerve blocks has provided insight into needle–nerve interactions, revealing distinct limitations of nerve stimulator techniques. Given that UGRA requires a unique set of skills, formal standards and guidelines are currently being developed by leadership societies in order to foster education and training. This review article, in a case vignette format, highlights important techniques, concepts, and limitations regarding the use of ultrasound to facilitate regional anesthesia. Clinically relevant aspects of ultrasound physics are also discussed. PMID:22915860
Diederich, S; Padge, B; Vossas, U; Hake, R; Eidt, S
2006-01-01
Purpose: To assess feasibility, results and complications in image-guided biopsies using a single needle design in various organs. Materials and methods: 100 consecutive percutaneous biopsies were performed in 54 females and 46 males aged 24–87 years (mean age/standard deviation: 64.5 +/− 12 years) using a full-core end-cut tri-axial full-automatic biopsy needle (18 gauge BioPince ™, InterV-MDTech, Gainesville, Florida) under CT (n=45) or ultrasound (n=55) guidance. In 63 biopsies a coaxial technique was used. Results: Biopsies were obtained of liver (n=32), lymph nodes (n=17), thyroid (n=11), lung (n=9), adrenal (n=9), pelvis (n=6), chest wall/pleura (n=6), mediastinum (n=4), lytic bone lesions (n=2), retroperitoneum (n=1), muscle (n=1), pancreas (n=1), peritoneum (n=1). Between 1 and 6 (mean/SD 2.83 +/− 0.92) needle passes were performed. In 77 cases a malignant (40 metastases, 37 primary tumours) and in 23 a benign lesion was diagnosed. Of the 23 benign lesions a specific diagnosis was possible in 22. In one case necrosis and haemorrhage was diagnosed. In this patient surgery and autopsy both revealed a mediastinal haematoma of unknown origin. Eight minor complications (mild pain/local haematoma requiring no therapy) and three major complications (three pneumothoraces in nine lung biopsies requiring two aspirations and one drainage) were observed. There was no mortality. Conclusion: Percutaneous image-guided biopsy using the described full-core end-cut needle resulted in a specific diagnosis in 99/100 consecutive biopsies in various organs with a low complication rate. We use this needle type for all CT- or US-guided biopsies in all organs except for solid bone. PMID:16766268
Endoscopic ultrasound elastography: Current status and future perspectives
Cui, Xin-Wu; Chang, Jian-Min; Kan, Quan-Cheng; Chiorean, Liliana; Ignee, Andre; Dietrich, Christoph F
2015-01-01
Elastography is a new ultrasound modality that provides images and measurements related to tissue stiffness. Endoscopic ultrasound (EUS) has played an important role in the diagnosis and management of numerous abdominal and mediastinal diseases. Elastography by means of EUS examination can assess the elasticity of tumors in the proximity of the digestive tract that are hard to reach with conventional transcutaneous ultrasound probes, such as pancreatic masses and mediastinal or abdominal lymph nodes, thus improving the diagnostic yield of the procedure. Results from previous studies have promised benefits for EUS elastography in the differential diagnosis of lymph nodes, as well as for assessing masses with pancreatic or gastrointestinal (GI) tract locations. It is important to mention that EUS elastography is not considered a modality that can replace biopsy. However, it may be a useful adjunct, improving the accuracy of EUS-fine needle aspiration biopsy (EUS-FNAB) by selecting the most suspicious area to be targeted. Even more, it may be useful for guiding further clinical management when EUS-FNAB is negative or inconclusive. In the present paper we will discuss the current knowledge of EUS elastography, including the technical aspects, along with its applications in the differential diagnosis between benign and malignant solid pancreatic masses and lymph nodes, as well as its aid in the differentiation between normal pancreatic tissues and chronic pancreatitis. Moreover, the emergent indication and future perspectives are summarized, such as the benefit of EUS elastography in EUS-guided fine needle aspiration biopsy, and its uses for characterization of lesions in liver, biliary tract, adrenal glands and GI tract. PMID:26715804
The utility of ultrasound in patients with melanoma.
Uren, Roger F; Sanki, Amira; Thompson, John F
2007-11-01
The highest quality gray-scale ultrasound images are obtained with high-frequency transducers; however, such high frequencies do not penetrate more than a few centimeters into body tissue. Fortunately, in patients with melanoma, the structures of interest are close to the skin surface, making them ideal targets for examination with high-resolution ultrasound. These include primary cutaneous melanomas, uveal melanomas and the regional lymph nodes draining the skin that lie in the axilla, groin, neck and other locations. Although ultrasound study of primary melanomas arising in the skin and eye has provided some insights, a major role for ultrasound has evolved recently, to provide early detection of metastatic melanoma in regional lymph nodes. Ultrasound is clearly superior to clinical palpation of the nodes during follow-up and, when combined with guided fine-needle biopsy, allows the earliest possible surgical intervention for regional nodal metastases. In the future the use of ultrasound contrast agents may improve the sensitivity of ultrasound in the detection of very small metastatic deposits.
A technical report on ultrasound-guided scapulocostal syndrome injection.
McCarthy, C; Harmon, D
2016-08-01
We describe a case report and technique for using an ultrasound scanner and a linear transducer to guide serratus posterior superior (SPS) muscle injection. A 43-year-old female presented with chronic pain centered under the right upper portion of her scapula impacting her activities of daily living. For the ultrasound-guided SPS muscle injection, the patient was placed in the prone position. The transducer was oriented in a transverse orientation at the level of the C6-T1 vertebrae. Here the SPS muscle attaches to the lower portion of the ligament nuchae and the intervening interspinous ligaments. The muscle fibers run inferiorly and laterally to attach to the 2nd-5th ribs which were identified along with the lateral portion of the serratus posterior superior muscle which is covered by the scapula. Real-time imaging was used to direct a spinal needle into the trigger points of the SPS muscle, where solution was injected under direct vision. The patient's pain symptoms improved significantly. Serratus posterior superior injection can confirm a diagnosis of scapulocostal syndrome and be therapeutically beneficial.
Kumar, Awanish; Pahwa, Harvinder Singh; Srivastava, Rohit; Khan, Khursheed Alam
2013-01-01
We encountered a patient who presented with neck swelling, difficulty in swallowing, voice change along with systemic features such as evening rise of temperature, chronic cough and weight loss. Ultrasonography of the thyroid gland revealed two cystic swellings. An ultrasound guided fine needle aspiration cytology was suggestive of tubercular abscess. The patient responded well to antigravity aspiration of the swellings and antitubercular treatment. PMID:23814203
Varghese, Linda; Ngae, Min Yi; Wilson, Andrew P; Crowder, Clinton D; Gulbahce, H Evin; Pambuccian, Stefan E
2009-11-01
Involvement of the pancreas by metastatic sarcoma is rare, and can prove challenging to differentiate from sarcomatoid carcinomas which occur more commonly. The endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) technique has been successfully used for the diagnosis of pancreatic carcinomas whether primary or metastatic, and is now considered the most effective noninvasive method for the identification of pancreatic metastases. However, to date very few reports detail the diagnosis of mesenchymal neoplasms by EUS-FNA. Herein, we report a series of four patients who underwent EUS-FNA of the pancreas, where the diagnosis of metastatic sarcoma was made based on morphology and ancillary studies. The cases include metastases of leiomyosarcoma, liposarcoma, alveolar rhabdomyosarcoma, and solitary fibrous tumor. The history of a primary sarcoma of the chest wall, mediastinum, and respectively lower extremity was known for the first three of these patients while in the case of the solitary fibrous tumor a remote history of a paraspinal "hemangiopericytoma" was only elicited after the EUS-FNA diagnosis was made. We conclude that EUS-FNA is efficient and accurate in providing a diagnosis of sarcoma, even in patients without a known primary sarcoma, thus allowing institution of therapy without additional biopsies.
Rapid diagnosis of liver cancer by ultrasound-guided fine-needle aspiration biopsy.
Huber, K; Heuhold, N
1987-01-01
Because of the relatively favorable prognosis to the patient with early detected hepatocarcinoma followed by surgical treatment if resection is possible, it is important to differentiate quickly between primary and secondary liver cancer. Ultrasound-guided percutaneous fine needle aspiration biopsy (US-FNAB) was used as a first diagnostic measure in patients with sonographic evidence of liver tumors. Biopsies were done under sonographic control and antiseptic conditions from the center and the border zone of solid tumors of the liver, and the aspirated cell material was air dried on glass slides and Giemsa stained. The cytologic diagnosis was proved by clinical course and in most cases by surgical or autoptic histology. Cytologic evaluation lead in 15 cases to the diagnosis of definitive or suspicious malignant liver disease; the sensitivity was 93% and the specificity was 87%. One case classified as suspicious for malignancy by cytologic examination could be identified as cirrhotic nodule by further investigations. In none of the patients did we find complications from the biopsy procedure. From these data it is concluded that US-FNAB can serve as a rapid, inexpensive, safe, and highly accurate first diagnostic step in patients with solid lesions of the liver.
Chen, Bo; Zhao, Yu; Gu, Jiangang; Wu, Huanwen; Liang, Zhiyong; Meng, Zhilan
2017-01-01
The Papanicolaou Society of Cytopathology has recently proposed a standardized terminology and nomenclature guidelines for pancreatic cytology. However the risk of malignancy associated with the new guidelines has been scarcely studied. In this study, a series of pancreatic cytology cases obtained by endoscopic ultrasound-guided fine-needle aspiration from 294 Chinese patients were retrospectively re-categorized into six categories according the new guidelines. The risks of malignancy were 18.1% for “negative,” 20.0% for “neoplastic,” 57.1% for “nondiagnostic,” 69.2% for “atypical,” 87.5% for “suspicious,” and 100.0% for “positive” respectively. The area under the receiver operating characteristic curve was 0.93 (95% Confidence Interval, 0.90-0.96), which was significantly higher than that associated with old classification system (0.82; 95% Confidence Interval, 0.77-0.87) conventionally used in China. Our investigation demonstrated that the new guidelines have a greater ability of risk stratification than the old classification system conventionally used in China. This may be helpful in giving better predictions of malignancy, thus leading to more personalized treatment strategies. PMID:28042957
Fiber optic photoacoustic probe with ultrasonic tracking for guiding minimally invasive procedures
NASA Astrophysics Data System (ADS)
Xia, Wenfeng; Mosse, Charles A.; Colchester, Richard J.; Mari, Jean Martial; Nikitichev, Daniil I.; West, Simeon J.; Ourselin, Sebastien; Beard, Paul C.; Desjardins, Adrien E.
2015-07-01
In a wide range of clinical procedures, accurate placement of medical devices such as needles and catheters is critical to optimize patient outcomes. Ultrasound imaging is often used to guide minimally invasive procedures, as it can provide real-time visualization of patient anatomy and medical devices. However, this modality can provide low image contrast for soft tissues, and poor visualization of medical devices that are steeply angled with respect to the incoming ultrasound beams. Photoacoustic sensors can provide information about the spatial distributions of tissue chromophores that could be valuable for guiding minimally invasive procedures. In this study, a system for guiding minimally invasive procedures using photoacoustic sensing was developed. This system included a miniature photoacoustic probe with three optical fibers: one with a bare end for photoacoustic excitation of tissue, a second for photoacoustic excitation of an optically absorbing coating at the distal end to transmit ultrasound, and a third with a Fabry-Perot cavity at the distal end for receiving ultrasound. The position of the photoacoustic probe was determined with ultrasonic tracking, which involved transmitting pulses from a linear-array ultrasound imaging probe at the tissue surface, and receiving them with the fiber-optic ultrasound receiver in the photoacoustic probe. The axial resolution of photoacoustic sensing was better than 70 μm, and the tracking accuracy was better than 1 mm in both axial and lateral dimensions. By translating the photoacoustic probe, depth scans were obtained from different spatial positions, and two-dimensional images were reconstructed using a frequency-domain algorithm.
Hematoma formation during breast core needle biopsy in women taking antithrombotic therapy.
Chetlen, Alison L; Kasales, Claudia; Mack, Julie; Schetter, Susann; Zhu, Junjia
2013-07-01
The purpose of this study was to compare hematoma formation after breast core needle biopsy performed on patients undergoing and those not undergoing concurrent antithrombotic therapy. A prospective assessment of core needle biopsies (stereotactic, ultrasound guided, or MRI guided) performed on patients enrolled between September 2011 and July 2012 formed the basis of this study. Postprocedure mediolateral and craniocaudal mammograms were evaluated for the presence and size of hematomas. Patients were clinically evaluated for complications 24-48 hours after the procedure through telephone call or face-to-face consultation. Needle size, type of biopsy, and presence of hematoma and documented complications were correlated with use of antithrombotic agents (including aspirin, warfarin, clopidogrel, and daily nonsteroidal antiinflammatory medications). No clinically significant hematomas or bleeding complications were found. Eighty-nine of 617 (14.4%) non-clinically significant hematomas were detected on postprocedure mammograms. The probability of development of a non-clinically significant hematoma was 21.6% for patients taking antithrombotics and 13.0% for those not taking antithrombotics. Concurrent antithrombotic therapy and larger needle gauge were significant factors contributing to the probability of hematoma formation. The volume of the hematoma was not related to needle gauge or presence of antithrombotic therapy. No clinically significant hematomas were found. Because there are potential life-threatening risks to stopping antithrombotic therapy before breast biopsy, withholding antithrombotic therapy for core needle breast biopsy is not recommended because the incidence of non-clinically significant hematoma is low.
López Ruiz, J A; Zabalza Estévez, I; Mieza Arana, J A
2016-01-01
To evaluate the possibility of determining the genetic profile of primary malignant tumors of the breast from specimens obtained by ultrasound-guided percutaneous biopsies during the diagnostic imaging workup. This is a retrospective study in 13 consecutive patients diagnosed with invasive breast cancer by B-mode ultrasound-guided 12 G core needle biopsy. After clinical indication, the pathologist decided whether the paraffin block specimens seemed suitable (on the basis of tumor size, validity of the sample, and percentage of tumor cells) before sending them for genetic analysis with the MammaPrint® platform. The size of the tumors on ultrasound ranged from 0.6cm to 5cm. In 11 patients the preserved specimen was considered valid and suitable for use in determining the genetic profile. In 1 patient (with a 1cm tumor) the pathologist decided that it was necessary to repeat the core biopsy to obtain additional samples. In 1 patient (with a 5cm tumor) the specimen was not considered valid by the genetic laboratory. The percentage of tumor cells in the samples ranged from 60% to 70%. In 11/13 cases (84.62%) it was possible to do the genetic analysis on the previously diagnosed samples. In most cases, regardless of tumor size, it is possible to obtain the genetic profile from tissue specimens obtained with ultrasound-guided 12 G core biopsy preserved in paraffin blocks. Copyright © 2015 SERAM. Published by Elsevier España, S.L.U. All rights reserved.
Iglesias García, Julio; Lariño-Noia, José; Abdulkader Nallib, Ihab; Lindkvist, Björn; Domínguez-Muñoz, J Enrique
2018-05-03
diagnosis of early chronic pancreatitis (CP) is hampered due to the low accuracy of current imaging techniques and the absence of methods for histological confirmation. We aimed to evaluate the efficacy of endoscopic ultrasound-guided fine needle biopsy (EUS-FNB) for the histological diagnosis of early CP. a prospective, cross-sectional, single-center study was designed. Consecutive patients referred for EUS with a clinical suspicion of CP were evaluated for inclusion into the study. Inclusion criteria were age > 18 years and indeterminate EUS findings for the diagnosis of CP according to the Rosemont classification. EUS-FNB of the body of the pancreas was performed with Procore™ needles. Tissue samples were immersed into a methanol-based buffered preservative solution for cytohistological evaluation. The quality of the samples obtained and the histological findings were evaluated. Procedure-related complications were recorded. the study was stopped after eleven patients were included due to safety concerns and poor diagnostic yield. The mean age of the patients was 50.3 years (range 33-70 years) and six were male. Samples were of poor quality in five cases, but were sufficient for cell-block evaluation. An inflammatory infiltration with mild fibrosis was identified in two cases and neither inflammatory infiltration nor fibrosis was identified in three cases. With regard to the other six cases, isolated inflammatory cells were observed in one case, although the cellularity was poor and unsuitable for cytological evaluation in five cases. There was one major complication (9.1%) of acute pancreatitis that required hospitalization for 48 hours. EUS-FNB is technically feasible in patients with EUS findings categorized as indeterminate for a CP diagnosis. However, the diagnostic yield is poor and there is a non-negligible risk of complications.
Fevre, Marie-Cécile; Vincent, Caroline; Picard, Julien; Vighetti, Arnaud; Chapuis, Claire; Detavernier, Maxime; Allenet, Benoît; Payen, Jean-François; Bosson, Jean-Luc; Albaladejo, Pierre
2018-02-01
Ultrasound (US) guided needle positioning is safer than anatomical landmark techniques for central venous access. Hand-eye coordination and execution time depend on the professional's ability, previous training and personal skills. Needle guidance positioning systems (GPS) may theoretically reduce execution time and facilitate needle positioning in specific targets, thus improving patient comfort and safety. Three groups of healthcare professionals (41 anaesthesiologists and intensivists, 41 residents in anaesthesiology and intensive care, 39 nurse anaesthetists) were included and required to perform 3 tasks (positioning the tip of a needle in three different targets in a silicon phantom) by using successively a conventional US-guided needle positioning and a needle GPS. We measured execution times to perform the tasks, hand-eye coordination and the number of repositioning occurrences or errors in handling the needle or the probe. Without the GPS system, we observed a significant inter-individual difference for execution time (P<0.05), hand-eye coordination and the number of errors/needle repositioning between physicians, residents and nurse anaesthetists. US training and video gaming were found to be independent factors associated with a shorter execution time. Use of GPS attenuated the inter-individual and group variability. We observed a reduced execution time and improved hand-eye coordination in all groups as compared to US without GPS. Neither US training, video gaming nor demographic personal or professional factors were found to be significantly associated with reduced execution time when GPS was used. US associated with GPS systems may improve safety and decrease execution time by reducing inter-individual variability between professionals for needle-handling procedures. Copyright © 2016 Société française d'anesthésie et de réanimation (Sfar). Published by Elsevier Masson SAS. All rights reserved.
Campoy, Luis; Bezuidenhout, Abraham J; Gleed, Robin D; Martin-Flores, Manuel; Raw, Robert M; Santare, Carrie L; Jay, Ariane R; Wang, Annie L
2010-03-01
To describe an ultrasound-guided technique and the anatomical basis for three clinically useful nerve blocks in dogs. Prospective experimental trial. Four hound-cross dogs aged 2 +/- 0 years (mean +/- SD) weighing 30 +/- 5 kg and four Beagles aged 2 +/- 0 years and weighing 8.5 +/- 0.5 kg. Axillary brachial plexus, femoral, and sciatic combined ultrasound/electrolocation-guided nerve blocks were performed sequentially and bilaterally using a lidocaine solution mixed with methylene blue. Sciatic nerve blocks were not performed in the hounds. After the blocks, the dogs were euthanatized and each relevant site dissected. Axillary brachial plexus block Landmark blood vessels and the roots of the brachial plexus were identified by ultrasound in all eight dogs. Anatomical examination confirmed the relationship between the four ventral nerve roots (C6, C7, C8, and T1) and the axillary vessels. Three roots (C7, C8, and T1) were adequately stained bilaterally in all dogs. Femoral nerve block Landmark blood vessels (femoral artery and femoral vein), the femoral and saphenous nerves and the medial portion of the rectus femoris muscle were identified by ultrasound in all dogs. Anatomical examination confirmed the relationship between the femoral vessels, femoral nerve, and the rectus femoris muscle. The femoral nerves were adequately stained bilaterally in all dogs. Sciatic nerve block. Ultrasound landmarks (semimembranosus muscle, the fascia of the biceps femoris muscle and the sciatic nerve) could be identified in all of the dogs. In the four Beagles, anatomical examination confirmed the relationship between the biceps femoris muscle, the semimembranosus muscle, and the sciatic nerve. In the Beagles, all but one of the sciatic nerves were stained adequately. Ultrasound-guided needle insertion is an accurate method for depositing local anesthetic for axillary brachial plexus, femoral, and sciatic nerve blocks.
Mao, Feng; Dong, Yi; Ji, Zhengbiao; Cao, Jiaying; Wang, Wen-Ping
2017-01-01
Aim. To investigate the value of contrast-enhanced ultrasound (CEUS) guided biopsy of undetermined abdominal lesions in multidisciplinary treatment (MDT) decision-making approach. Methods. Between Jan 2012 and Dec 2015, 60 consecutive patients (male, 37; female, 23; mean age, 51.3 years ± 14.6) who presented with undetermined abdominal lesions were included. CEUS and core needle percutaneous biopsy was performed under real-time CEUS guidance in all lesions. Data were recorded and compared with conventional ultrasound (US) guidance group ( n = 75). All CEUS findings and clinical data were evaluated in MDT. Results. CEUS enabled the delimitation of more (88.3% versus 41.3%) and larger (14.1 ± 10.7 mm versus 32.3 ± 18.5 mm) nonenhanced necrotic areas. More inner (20.0% versus 6.7%) and surrounding (18.3% versus 2.7%) major vessels were visualized and avoided during biopsies. CEUS-guided biopsy increased the diagnostic accuracy from 93.3% to 98.3%, with correct diagnosis in 57 of 60 lesions (95.0%). The therapeutic plan was influenced by CEUS guided biopsies findings in the majority of patients (98.3%). Conclusion. The combination of CEUS guided biopsy and MDT decision-making approach is useful in the diagnostic work-up and therapeutic management.
Imaoka, Hiroshi; Yamao, Kenji; Bhatia, Vikram; Shimizu, Yasuhiro; Yatabe, Yasushi; Koshikawa, Takashi; Kinoshita, Yoshikazu
2009-01-01
Tumors other than ductal adenocarcinomas constitute 10%-15% of all pancreatic tumors. We describe the performance and pitfalls of endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) for diagnosis of these rare pancreatic tumors and their characteristic cytopathological features. The records of 455 pancreatic fine-needle aspiration procedures done between March 1997 and August 2006 at Aichi Cancer Center, Nagoya, Japan, were reviewed. Besides cytology, aspirated material was routinely submitted in formalin for cell-block analysis. The reference standard for final diagnosis was surgical pathology from resected specimens. Twenty-eight rare (nonductal adenocarcinomas) pancreatic tumors were identified. Overall, EUS-FNA with the results of cytology, cell-block processing, and immunohistochemistry could correctly diagnose the type of neoplasm in 19 (67.9%) cases. EUS-FNA could distinguish benign from malignant rare tumors with a sensitivity of 69.2%, a specificity of 100%, positive predictive value of 100%, negative predictive value of 79.0%, and accuracy of 85.7%. None of three malignant pancreatic endocrine neoplasms could be diagnosed as malignant. An adequate core tissue sample could be obtained in 21 cases (75.0%) and provide a histopathological diagnosis in 19 (67.9%) cases. EUS-FNA could change the presumptive diagnosis in 11 (39.3%) cases. Specific immunochemical studies were useful adjuncts to the diagnosis. No major or minor complication was noted in any patient. Pancreatic neoplasms other than ductal adenocarcinomas have diverse imaging and histopathological features. EUS-FNA is accurate and safe for their identification.
NASA Astrophysics Data System (ADS)
Song, Sang-Eun; Tokuda, Junichi; Tuncali, Kemal; Tempany, Clare; Hata, Nobuhiko
2012-02-01
Image guided prostate interventions have been accelerated by Magnetic Resonance Imaging (MRI) and robotic technologies in the past few years. However, transrectal ultrasound (TRUS) guided procedure still remains as vast majority in clinical practice due to engineering and clinical complexity of the MRI-guided robotic interventions. Subsequently, great advantages and increasing availability of MRI have not been utilized at its maximum capacity in clinic. To benefit patients from the advantages of MRI, we developed an MRI-compatible motorized needle guide device "Smart Template" that resembles a conventional prostate template to perform MRI-guided prostate interventions with minimal changes in the clinical procedure. The requirements and specifications of the Smart Template were identified from our latest MRI-guided intervention system that has been clinically used in manual mode for prostate biopsy. Smart Template consists of vertical and horizontal crossbars that are driven by two ultrasonic motors via timing-belt and mitergear transmissions. Navigation software that controls the crossbar position to provide needle insertion positions was also developed. The software can be operated independently or interactively with an open-source navigation software, 3D Slicer, that has been developed for prostate intervention. As preliminary evaluation, MRI distortion and SNR test were conducted. Significant MRI distortion was found close to the threaded brass alloy components of the template. However, the affected volume was limited outside the clinical region of interest. SNR values over routine MRI scan sequences for prostate biopsy indicated insignificant image degradation during the presence of the robotic system and actuation of the ultrasonic motors.
Ultrasound-guided Subclavian Vein Cannulation Using a Micro-Convex Ultrasound Probe
Fair, James; Hirshberg, Eliotte L.; Grissom, Colin K.; Brown, Samuel M.
2014-01-01
Background: The subclavian vein is the preferred site for central venous catheter placement due to infection risk and patient comfort. Ultrasound guidance is useful in cannulation of other veins, but for the subclavian vein, current ultrasound-guided techniques using high-frequency linear array probes are generally limited to axillary vein cannulation. Methods: We report a series of patients who underwent clinically indicated subclavian venous catheter placement using a micro-convex pediatric probe for real-time guidance in the vein’s longitudinal axis. We identified rates of successful placement and complications by chart review. Results: Twenty-four catheters were placed using the micro-convex pediatric probe with confirmation of placement of the needle medial to the lateral border of the first rib. Sixteen of the catheters were placed by trainee physicians. In 23 patients, the catheter was placed without complication (hematoma, pneumothorax, infection). In one patient, the vein could not be safely cannulated without risk of arterial puncture, so an alternative site was selected. Conclusions: Infraclavicular subclavian vein cannulation using real-time ultrasound with a micro-convex pediatric probe appears to be a safe and effective method of placing subclavian vascular catheters. This technique merits further study to confirm safety and efficacy. PMID:24611628
NASA Astrophysics Data System (ADS)
Beigi, Parmida; Salcudean, Tim; Rohling, Robert; Lessoway, Victoria A.; Ng, Gary C.
2015-03-01
This paper presents a new needle detection technique for ultrasound guided interventions based on the spectral properties of small displacements arising from hand tremour or intentional motion. In a block-based approach, the displacement map is computed for each block of interest versus a reference frame, using an optical flow technique. To compute the flow parameters, the Lucas-Kanade approach is used in a multiresolution and regularized form. A least-squares fit is used to estimate the flow parameters from the overdetermined system of spatial and temporal gradients. Lateral and axial components of the displacement are obtained for each block of interest at consecutive frames. Magnitude-squared spectral coherency is derived between the median displacements of the reference block and each block of interest, to determine the spectral correlation. In vivo images were obtained from the tissue near the abdominal aorta to capture the extreme intrinsic body motion and insertion images were captured from a tissue-mimicking agar phantom. According to the analysis, both the involuntary and intentional movement of the needle produces coherent displacement with respect to a reference window near the insertion site. Intrinsic body motion also produces coherent displacement with respect to a reference window in the tissue; however, the coherency spectra of intrinsic and needle motion are distinguishable spectrally. Blocks with high spectral coherency at high frequencies are selected, estimating a channel for needle trajectory. The needle trajectory is detected from locally thresholded absolute displacement map within the initial estimate. Experimental results show the RMS localization accuracy of 1:0 mm, 0:7 mm, and 0:5 mm for hand tremour, vibrational and rotational needle movements, respectively.
NASA Astrophysics Data System (ADS)
Sadeghi Neshat, Hamid; Bax, Jeffery; Barker, Kevin; Gardi, Lori; Chedalavada, Jason; Kakani, Nirmal; Fenster, Aaron
2014-03-01
Image-guided percutaneous ablation is the standard treatment for focal liver tumors deemed inoperable and is commonly used to maintain eligibility for patients on transplant waitlists. Radiofrequency (RFA), microwave (MWA) and cryoablation technologies are all delivered via one or a number of needle-shaped probes inserted directly into the tumor. Planning is mostly based on contrast CT/MRI. While intra-procedural CT is commonly used to confirm the intended probe placement, 2D ultrasound (US) remains the main, and in some centers the only imaging modality used for needle guidance. Corresponding intraoperative 2D US with planning and other intra-procedural imaging modalities is essential for accurate needle placement. However, identification of matching features of interest among these images is often challenging given the limited field-of-view (FOV) and low quality of 2D US images. We have developed a passive tracking arm with a motorized scan-head and software tools to improve guiding capabilities of conventional US by large FOV 3D US scans that provides more anatomical landmarks that can facilitate registration of US with both planning and intra-procedural images. The tracker arm is used to scan the whole liver with a high geometrical accuracy that facilitates multi-modality landmark based image registration. Software tools are provided to assist with the segmentation of the ablation probes and tumors, find the 2D view that best shows the probe(s) from a 3D US image, and to identify the corresponding image from planning CT scans. In this paper, evaluation results from laboratory testing and a phase 1 clinical trial for planning and guiding RFA and MWA procedures using the developed system will be presented. Early clinical results show a comparable performance to intra-procedural CT that suggests 3D US as a cost-effective alternative with no side-effects in centers where CT is not available.
Valera-Garrido, Fermín; Minaya-Muñoz, Francisco; Medina-Mirapeix, Francesc
2014-12-01
Ultrasound (US)-guided percutaneous needle electrolysis (PNE) is a novel minimally invasive approach which consists of the application of a galvanic current through an acupuncture needle. To evaluate the clinical and ultrasonographic effectiveness of a multimodal programme (PNE, eccentric exercise (EccEx) and stretching) in the short term for patients with chronic lateral epicondylitis, and to determine whether the clinical outcomes achieved decline over time. A one-way repeated measures study was performed in a clinical setting in 36 patients presenting with lateral epicondylitis. The patients received one session of US-guided PNE per week over 4-6 weeks, associated with a home programme of EccEx and stretching. The main outcome measures were severity of pain, disability (Disabilities of the Arm, Shoulder and Hand (DASH) questionnaire), structural tendon changes (US), hypervascularity and patients' perceptions of overall outcome. Measurements at 6, 26 and 52 weeks follow-up included recurrence rates (increase in severity of pain or disability compared with discharge), perception of overall outcome and success rates. All outcome measures registered significant improvements between pre-intervention and discharge. Most patients (n=30, 83.3%) rated the overall outcome as 'successful' at 6 weeks. The ultrasonographic findings showed that the hypoechoic regions and hypervascularity of the extensor carpi radialis brevis changed significantly. At 26 and 52 weeks, all participants (n=32) perceived a 'successful' outcome. Recurrence rates were null after discharge and at follow-up at 6, 26 and 52 weeks. Symptoms and degenerative structural changes of chronic lateral epicondylitis are reduced after US-guided PNE associated with EccEx and stretching, with encouragingly low recurrences in the mid to long term. ClinicalTrials.gov identifier: NCT02085928. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Johnson, S J; Hunt, C M; Woolnough, H M; Crawshaw, M; Kilkenny, C; Gould, D A; England, A; Sinha, A; Villard, P F
2012-01-01
Objectives The aim of this article was to identify and prospectively investigate simulated ultrasound-guided targeted liver biopsy performance metrics as differentiators between levels of expertise in interventional radiology. Methods Task analysis produced detailed procedural step documentation allowing identification of critical procedure steps and performance metrics for use in a virtual reality ultrasound-guided targeted liver biopsy procedure. Consultant (n=14; male=11, female=3) and trainee (n=26; male=19, female=7) scores on the performance metrics were compared. Ethical approval was granted by the Liverpool Research Ethics Committee (UK). Independent t-tests and analysis of variance (ANOVA) investigated differences between groups. Results Independent t-tests revealed significant differences between trainees and consultants on three performance metrics: targeting, p=0.018, t=−2.487 (−2.040 to −0.207); probe usage time, p = 0.040, t=2.132 (11.064 to 427.983); mean needle length in beam, p=0.029, t=−2.272 (−0.028 to −0.002). ANOVA reported significant differences across years of experience (0–1, 1–2, 3+ years) on seven performance metrics: no-go area touched, p=0.012; targeting, p=0.025; length of session, p=0.024; probe usage time, p=0.025; total needle distance moved, p=0.038; number of skin contacts, p<0.001; total time in no-go area, p=0.008. More experienced participants consistently received better performance scores on all 19 performance metrics. Conclusion It is possible to measure and monitor performance using simulation, with performance metrics providing feedback on skill level and differentiating levels of expertise. However, a transfer of training study is required. PMID:21304005
Lee, Wonyou; Song, Kilyoung; Lee, Inhyung; Shin, Hyungdo; Lee, Byeong Chun; Yeon, Seongchan; Jang, Goo
2015-01-01
Transvaginal ultrasound-guided follicle aspiration is one method of obtaining recipient oocytes for equine somatic cell nuclear transfer (SCNT). This study was conducted: (1) to evaluate the possibility of oocyte aspiration from pre-ovulatory follicles using a short disposable needle system (14-G) by comparing the oocyte recovery rate with that of a long double lumen needle (12-G); (2) to investigate the developmental competence of recovered oocytes after SCNT and embryo transfer. The recovery rates with the short disposable needle vs. the long needle were not significantly different (47.5% and 35.0%, respectively). Twenty-six SCNT embryos were transferred to 13 mares, and one mare delivered a live offspring at Day 342. There was a perfect identity match between the cloned foal and the cell donor after analysis of microsatellite DNA, and the mitochondrial DNA of the cloned foal was identical with that of the oocyte donor. These results demonstrated that the short disposable needle system can be used to recover oocytes to use as cytoplasts for SCNT, in the production of cloned foals and for other applications in equine embryology.
Delay and Standard Deviation Beamforming to Enhance Specular Reflections in Ultrasound Imaging.
Bandaru, Raja Sekhar; Sornes, Anders Rasmus; Hermans, Jeroen; Samset, Eigil; D'hooge, Jan
2016-12-01
Although interventional devices, such as needles, guide wires, and catheters, are best visualized by X-ray, real-time volumetric echography could offer an attractive alternative as it avoids ionizing radiation; it provides good soft tissue contrast, and it is mobile and relatively cheap. Unfortunately, as echography is traditionally used to image soft tissue and blood flow, the appearance of interventional devices in conventional ultrasound images remains relatively poor, which is a major obstacle toward ultrasound-guided interventions. The objective of this paper was therefore to enhance the appearance of interventional devices in ultrasound images. Thereto, a modified ultrasound beamforming process using conventional-focused transmit beams is proposed that exploits the properties of received signals containing specular reflections (as arising from these devices). This new beamforming approach referred to as delay and standard deviation beamforming (DASD) was quantitatively tested using simulated as well as experimental data using a linear array transducer. Furthermore, the influence of different imaging settings (i.e., transmit focus, imaging depth, and scan angle) on the obtained image contrast was evaluated. The study showed that the image contrast of specular regions improved by 5-30 dB using DASD beamforming compared with traditional delay and sum (DAS) beamforming. The highest gain in contrast was observed when the interventional device was tilted away from being orthogonal to the transmit beam, which is a major limitation in standard DAS imaging. As such, the proposed beamforming methodology can offer an improved visualization of interventional devices in the ultrasound image with potential implications for ultrasound-guided interventions.
Electromagnetic navigation diagnostic bronchoscopy for small peripheral lung lesions.
Makris, D; Scherpereel, A; Leroy, S; Bouchindhomme, B; Faivre, J-B; Remy, J; Ramon, P; Marquette, C-H
2007-06-01
The present study prospectively evaluated the diagnostic yield and safety of electromagnetic navigation-guided bronchoscopy biopsy, for small peripheral lung lesions in patients where standard techniques were nondiagnostic. The study was conducted in a tertiary medical centre on 40 consecutive patients considered unsuitable for straightforward surgery or computed tomography (CT)-guided transthoracic needle aspiration biopsy, due to comorbidities. The lung lesion diameter was mean+/-sem 23.5+/-1.5 mm and the depth from the visceral-costal pleura was 14.9+/-2 mm. Navigation was facilitated by an electromagnetic tracking system which could detect a position sensor incorporated into a flexible catheter advanced through a bronchoscope. Information obtained during bronchoscopy was superimposed on previously acquired CT data. Divergence between CT data and data obtained during bronchoscopy was calculated by the system's software as a measure of navigational accuracy. All but one of the target lesions was reached and the overall diagnostic yield was 62.5% (25-40). Diagnostic yield was significantly affected by CT-to-body divergence; yield was 77.2% when estimated divergence was
Joeng, Eui Soo; Jeong, Young Cheol; Park, Bum Jun; Kang, Seok; Yang, Seung Nam
2016-01-01
Objective To evaluate the risk of phrenic nerve injury during ultrasound-guided stellate ganglion block (US-SGB) according to sonoanatomy of the phrenic nerve, and determine a safer posture for needle insertion by assessing its relationship with surrounding structure according to positional change. Methods Twenty-nine healthy volunteers were recruited and underwent ultrasound in two postures, i.e., supine position with the neck extension and head rotation, and lateral decubitus position. The transducer was placed at the anterior tubercle of the C6 level to identify phrenic nerve. The cross-sectional area (CSA), depth from skin, distance between phrenic nerve and anterior tubercle of C6 transverse process, and the angle formed by anterior tubercle, posterior tubercle and phrenic nerve were measured. Results The phrenic nerve was clearly identified in the intermuscular fascia layer between the anterior scalene and sternocleidomastoid muscles. The distance between the phrenic nerve and anterior tubercle was 10.33±3.20 mm with the supine position and 9.20±3.31 mm with the lateral decubitus position, respectively. The mean CSA and skin depth of phrenic nerve were not statistically different between the two positions. The angle with the supine position was 48.37°±27.43°, and 58.89°±30.02° with the lateral decubitus position. The difference of angle between the two positions was statistically significant. Conclusion Ultrasound is a useful tool for assessing the phrenic nerve and its anatomical relation with other cervical structures. In addition, lateral decubitus position seems to be safer by providing wider angle for needle insertion than the supine position in US-SGB. PMID:27152274
Joeng, Eui Soo; Jeong, Young Cheol; Park, Bum Jun; Kang, Seok; Yang, Seung Nam; Yoon, Joon Shik
2016-04-01
To evaluate the risk of phrenic nerve injury during ultrasound-guided stellate ganglion block (US-SGB) according to sonoanatomy of the phrenic nerve, and determine a safer posture for needle insertion by assessing its relationship with surrounding structure according to positional change. Twenty-nine healthy volunteers were recruited and underwent ultrasound in two postures, i.e., supine position with the neck extension and head rotation, and lateral decubitus position. The transducer was placed at the anterior tubercle of the C6 level to identify phrenic nerve. The cross-sectional area (CSA), depth from skin, distance between phrenic nerve and anterior tubercle of C6 transverse process, and the angle formed by anterior tubercle, posterior tubercle and phrenic nerve were measured. The phrenic nerve was clearly identified in the intermuscular fascia layer between the anterior scalene and sternocleidomastoid muscles. The distance between the phrenic nerve and anterior tubercle was 10.33±3.20 mm with the supine position and 9.20±3.31 mm with the lateral decubitus position, respectively. The mean CSA and skin depth of phrenic nerve were not statistically different between the two positions. The angle with the supine position was 48.37°±27.43°, and 58.89°±30.02° with the lateral decubitus position. The difference of angle between the two positions was statistically significant. Ultrasound is a useful tool for assessing the phrenic nerve and its anatomical relation with other cervical structures. In addition, lateral decubitus position seems to be safer by providing wider angle for needle insertion than the supine position in US-SGB.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kawai, T., E-mail: t-kawai@hosp.yoka.hyogo.jp; Kaminou, T., E-mail: kaminout@grape.med.tottori-u.ac.jp; Sugiura, K.
2010-02-15
To evaluate the efficacy of radiofrequency lung ablation with transbronchial saline injection. The bilateral lungs of eight living swine were used. A 13-gauge bone biopsy needle was inserted percutaneously into the lung, and 1 ml of muscle paste was injected to create a tumor mimic. In total, 21 nodules were ablated. In the saline injection group (group A), radiofrequency ablation (RFA) was performed for 11 nodules after transbronchial saline injection under balloon occlusion with a 2-cm active single internally cooled electrode. In the control group (group B), conventional RFA was performed for 10 nodules as a control. The infused salinemore » liquid showed a wedge-shaped and homogeneous distribution surrounding a tumor mimic. All 21 RFAs were successfully completed. The total ablation time was significantly longer (13.4 {+-} 2.8 min vs. 8.9 {+-} 3.5 min; P = 0.0061) and the tissue impedance was significantly lower in group A compared with group B (73.1 {+-} 8.8 {Omega} vs. 100.6 {+-} 16.6 {Omega}; P = 0.0002). The temperature of the ablated area was not significantly different (69.4 {+-} 9.1{sup o}C vs. 66.0 {+-} 7.9{sup o}C; P = 0.4038). There was no significant difference of tumor mimic volume (769 {+-} 343 mm{sup 3} vs. 625 {+-} 191 mm{sup 3}; P = 0.2783). The volume of the coagulated area was significantly larger in group A than in group B (3886 {+-} 1247 mm{sup 3} vs. 2375 {+-} 1395 mm{sup 3}; P = 0.0221). Percutaneous radiofrequency lung ablation combined with transbronchial saline injection can create an extended area of ablation.« less
Ultrasound-guided cable-free 13-gauge vacuum-assisted biopsy of non-mass breast lesions
Seo, Jiwoon; Jang, Mijung; Yun, Bo La; Lee, Soo Hyun; Kim, Eun-Kyu; Kang, Eunyoung; Park, So Yeon; Moon, Woo Kyung; Choi, Hye Young; Kim, Bohyoung
2017-01-01
Purpose To compare the outcomes of ultrasound-guided core biopsy for non-mass breast lesions by the novel 13-gauge cable-free vacuum-assisted biopsy (VAB) and by the conventional 14-gauge semi-automated core needle biopsy (CCNB). Materials and methods Our institutional review board approved this prospective study, and all patients provided written informed consent. Among 1840 ultrasound-guided percutaneous biopsies performed from August 2013 to December 2014, 145 non-mass breast lesions with suspicious microcalcifications on mammography or corresponding magnetic resonance imaging finding were subjected to 13-gauge VAB or 14-gauge CCNB. We evaluated the technical success rates, average specimen numbers, and tissue sampling time. We also compared the results of percutaneous biopsy and final surgical pathologic diagnosis to analyze the rates of diagnostic upgrade or downgrade. Results Ultrasound-guided VAB successfully targeted and sampled all lesions, whereas CCNB failed to demonstrate calcification in four (10.3%) breast lesions with microcalcification on specimen mammography. The mean sampling time were 238.6 and 170.6 seconds for VAB and CCNB, respectively. No major complications were observed with either method. Ductal carcinoma in situ (DCIS) and atypical ductal hyperplasia (ADH) lesions were more frequently upgraded after CCNB (8/23 and 3/5, respectively) than after VAB (2/26 and 0/4, respectively P = 0.028). Conclusion Non-mass breast lesions were successfully and accurately biopsied using cable-free VAB. The underestimation rate of ultrasound-detected non-mass lesion was significantly lower with VAB than with CCNB. Trial registration CRiS KCT0002267. PMID:28628656
Mari, Jean Martial; West, Simeon J.; Pratt, Rosalind; David, Anna L.; Ourselin, Sebastien; Beard, Paul C.; Desjardins, Adrien E.
2016-01-01
Precise device guidance is important for interventional procedures in many different clinical fields including fetal medicine, regional anesthesia, interventional pain management, and interventional oncology. While ultrasound is widely used in clinical practice for real-time guidance, the image contrast that it provides can be insufficient for visualizing tissue structures such as blood vessels, nerves, and tumors. This study was centered on the development of a photoacoustic imaging system for interventional procedures that delivered excitation light in the ranges of 750 to 900 nm and 1150 to 1300 nm, with an optical fiber positioned in a needle cannula. Coregistered B-mode ultrasound images were obtained. The system, which was based on a commercial ultrasound imaging scanner, has an axial resolution in the vicinity of 100 μm and a submillimeter, depth-dependent lateral resolution. Using a tissue phantom and 800 nm excitation light, a simulated blood vessel could be visualized at a maximum distance of 15 mm from the needle tip. Spectroscopic contrast for hemoglobin and lipids was observed with ex vivo tissue samples, with photoacoustic signal maxima consistent with the respective optical absorption spectra. The potential for further optimization of the system is discussed. PMID:26263417
Determining procedures for simulation-based training in radiology: a nationwide needs assessment.
Nayahangan, Leizl Joy; Nielsen, Kristina Rue; Albrecht-Beste, Elisabeth; Bachmann Nielsen, Michael; Paltved, Charlotte; Lindorff-Larsen, Karen Gilboe; Nielsen, Bjørn Ulrik; Konge, Lars
2018-06-01
New training modalities such as simulation are widely accepted in radiology; however, development of effective simulation-based training programs is challenging. They are often unstructured and based on convenience or coincidence. The study objective was to perform a nationwide needs assessment to identify and prioritize technical procedures that should be included in a simulation-based curriculum. A needs assessment using the Delphi method was completed among 91 key leaders in radiology. Round 1 identified technical procedures that radiologists should learn. Round 2 explored frequency of procedure, number of radiologists performing the procedure, risk and/or discomfort for patients, and feasibility for simulation. Round 3 was elimination and prioritization of procedures. Response rates were 67 %, 70 % and 66 %, respectively. In Round 1, 22 technical procedures were included. Round 2 resulted in pre-prioritization of procedures. In round 3, 13 procedures were included in the final prioritized list. The three highly prioritized procedures were ultrasound-guided (US) histological biopsy and fine-needle aspiration, US-guided needle puncture and catheter drainage, and basic abdominal ultrasound. A needs assessment identified and prioritized 13 technical procedures to include in a simulation-based curriculum. The list may be used as guide for development of training programs. • Simulation-based training can supplement training on patients in radiology. • Development of simulation-based training should follow a structured approach. • The CAMES Needs Assessment Formula explores needs for simulation training. • A national Delphi study identified and prioritized procedures suitable for simulation training. • The prioritized list serves as guide for development of courses in radiology.
McCrary, Hilary C; Faucett, Erynne A; Hurbon, Audriana N; Milinic, Tijana; Cervantes, Jose A; Kent, Sean L; Adamas-Rappaport, William J
2017-07-01
Objective The aim of our study is to determine if a fresh cadaver model (FCM) for the instruction of ultrasound (US)-guided fine-needle aspiration (FNA) of thyroid nodules is a practical method for instruction. Study Design Pre- and postinstruction assessment of medical students' ability to perform US-guided FNA of artificially created thyroid nodules placed adjacent to the thyroid gland of a fresh cadaver. Setting University-based fresh cadaver laboratory. Subjects and Methods Study participants included a total of 17 first- and second-year medical students with minimal US training. Technical skills were assessed using a 10-item checklist. In addition, a cognitive assessment regarding the indications, contraindications, and complications of the procedure was completed. A postinstruction assessment was provided for participants 5 weeks after their initial assessment. Differences between pre- and postinstruction assessment scores of technical skills were analyzed using McNemar's test. The mean cognitive knowledge gain was analyzed using a paired 2-sample t test. Results Eight of 10 items on the skills checklist were statistically significant between pre- and postinstruction skills assessment ( P < .05). There was a statistically significant change in cognitive knowledge gain regarding the contraindications of the procedure ( P = .001), but not for indications or complications ( P = .104 and P = .111, respectively). Conclusion US-guided FNA continues to be an important diagnostic procedure in the workup of thyroid nodules, making it an essential skill to integrate into surgical skills lab. Our FCM for the instruction of US-guided FNA is the first of its kind, and this pilot study shows this is a viable method for instruction.
Indications for axillary ultrasound use in breast cancer patients.
Joh, Jennifer E; Han, Gang; Kiluk, John V; Laronga, Christine; Khakpour, Nazanin; Lee, M Catherine
2012-12-01
Axillary ultrasound has been adopted for preoperative planning in breast cancer. Our objective was to determine features predictive of abnormal AUS and/or positive axillary node needle biopsy (NBx). Single-institution database of breast cancer patients identified patients with preoperative AUS. Patient characteristics and outcomes were correlated with AUS and NBx. Significant features were identified using univariable and multivariable analysis and correlative statistics. Three hundred thirteen breast cancers were evaluated. Abnormal AUS was demonstrated in 250 cases (80%). Node needle biopsy was performed in 247 cases (79%). Sensitivity and specificity was 93% and 48% for AUS and 86% and 100% for NBx, respectively. Palpable axillary adenopathy was significant in logistic regression model (P < .05). There were positive correlations between tumor grade, clinical T and tumor-node-metastasis stage, invasive ductal carcinoma histology, and inflammatory breast carcinoma with AUS and NBx (P < .05). Clinicopathologic features (grade, histology, tumor size) might help guide judicious use of AUS. Copyright © 2012 Elsevier Inc. All rights reserved.
Alderliesten, Tanja; Loo, Claudette; Paape, Anita; Muller, Sara; Rutgers, Emiel; Peeters, Marie-Jeanne Vrancken; Gilhuijs, Kenneth
2010-06-01
The aim of this study was to investigate the feasibility of image-guided navigation approaches to demarcate breast cancer on the basis of preacquired magnetic resonance (MR) imaging in supine patient orientation. Strategies were examined to minimize the uncertainty in the instrument-tip position, based on the hypothesis that the release of instrument pressure returns the breast tissue to its predeformed state. For this purpose, four sources of uncertainty were taken into account: (1) U(ligaments): Uncertainty in the reproducibility of the internal mammary gland geometry during repeat patient setup in supine orientation; (2) U(r_breathing): Residual uncertainty in registration of the breast after compensation for breathing motion using an external marker; (3) U(reconstruction): Uncertainty in the reconstructed location of the tip of the needle using an optical image-navigation system (phantom experiments, n = 50); and (4) U(deformation): Uncertainty in displacement of breast tumors due to needle-induced tissue deformations (patients, n = 21). A Monte Carlo study was performed to establish the 95% confidence interval (CI) of the combined uncertainties. This region of uncertainty was subsequently visualized around the reconstructed needle tip as an additional navigational aid in the preacquired MR images. Validation of the system was performed in five healthy volunteers (localization of skin markers only) and in two patients. In the patients, the navigation system was used to monitor ultrasound-guided radioactive seed localization of breast cancer. Nearest distances between the needle tip and the tumor boundary in the ultrasound images were compared to those in the concurrently reconstructed MR images. Both U(reconstruction) and U(deformation) were normally distributed with 0.1 +/- 1.2 mm (mean +/- 1 SD) and 0.1 +/- 0.8 mm, respectively. Taking prior estimates for U(ligaments) (0.0 +/- 1.5 mm) and U(r_breathing) (-0.1 +/- 0.6 mm) into account, the combined impact resulted in 3.9 mm uncertainty in the position of the needle tip (95% CI) after release of pressure. The volunteer study showed a targeting accuracy comparable to that in the phantom experiments: 2.9 +/- 1.3 versus 2.7 +/- 1.1 mm, respectively. In the patient feasibility study, the deviations were within the 3.9 mm CI. Image-guided navigation to demarcate breast cancer on the basis of preacquired MR images in supine orientation appears feasible if patient breathing is tracked during the navigation procedure, positional uncertainty is visualized and pressure on the localization instrument is released prior to verification of its position.
Photoacoustic and Ultrasonic Image-Guided Needle Biopsy of the Prostate
2015-10-01
improved spectral fidelity (i.e., reduced redshift in obtained spectra) using the Verasonics ultrasound platform, is suited for eventual clinical...trials. The Verasonics acquisition is performed in a Delrin holder and coordinated with a LabVIEW data acquisition device to allow for energy... Verasonics Inc., Toronto, Canada), the ratio of PA signal at 850 vs 750 nm was calculated for each oxygenation concentration (Fig. 5) to achieve
Photoacoustic and Ultrasonic Image-Guided Needle Biopsy of the Prostate
2015-02-01
demonstrated in Figures 2 & 3 were performed with a linear array coupled with a Verasonics Vantage 128 US system ( Verasonics Inc., Redmond, WA...the Verasonics ultrasound platform, is suited for eventual clinical trials. The Verasonics acquisition is coordinated with a LabVIEW data...Recently we acquired and integrated an ATL C9-5 end-fire transrectal array (Philips Medical Systems, Bothell, WA) with our Verasonics system. Figure 3
Stanger, Dylan; Shuster, Constantin; Telford, Jennifer; Lam, Eric
2016-01-01
Background. There is a high incidence of inconclusive cytopathology at initial EUS-FNA (endoscopic ultrasound-guided fine-needle aspiration) for suspected malignant pancreatic lesions. To obtain appropriate preoperative or palliative chemotherapy for pancreatic cancer, definitive cytopathology is often required. The utility of repeat EUS-FNA is not well established. Methods. A retrospective cohort study was conducted evaluating the yield of repeat EUS-FNA in determining a cytological diagnosis in patients who had undergone a prior EUS-FNA for diagnosis of suspected malignant pancreatic lesions with inconclusive cytopathology. The wait times to the second procedure and to decisions regarding therapy were calculated. Results. Overall, 45 repeat EUS-FNA procedures were performed over seven years for suspected malignant pancreatic lesions. Cytopathological class (I to IV) changed between first and second EUS-FNA in 32 patients (71%). Of 34 patients with an initially nonconclusive diagnosis, 20 had a conclusive diagnosis (59%) on repeat EUS-FNA. The cumulative yield after repeat EUS-FNA for definite pancreatic adenocarcinoma was 7 (16%). The median time interval between first and second EUS-FNA was 31 (7–175) days. Conclusions. A substantial number of patients had a definitive diagnosis of adenocarcinoma on repeat FNA and were, therefore, subsequently able to access appropriate care. PMID:27648440
Hwang, Chang Yun; Song, Tae Jun; Moon, Sung-Hoon; Lee, Don; Park, Do Hyun; Seo, Dong Wan; Lee, Sung Koo; Kim, Myung-Hwan
2009-01-01
Background/Aims Although endoscopic ultrasound guided fine needle aspiration (EUS-FNA) has been introduced and its use has been increasing in Korea, there have not been many reports about its performance. The aim of this study was to assess the utility of EUS-FNA without on-site cytopathologist in establishing the diagnosis of solid pancreatic and peripancreatic masses from a single institution in Korea. Methods Medical records of 139 patients who underwent EUS-FNA for pancreatic and peripancreatic solid mass in the year 2007, were retrospectively reviewed. By comparing cytopathologic diagnosis of FNA with final diagnosis, sensitivity, specificity, and accuracy were determined, and factors influencing the accuracy as well as complications were analyzed. Results One hundred twenty out of 139 cases had final diagnosis of malignancy. Sensitivity, specificity, and accuracy of EUS-FNA were 82%, 89%, and 83%, respectively, and positive and negative predictive values were 100% and 46%, respectively. As for factors influencing the accuracy of FNA, lesion size was marginally significant (p-value 0.08) by multivariate analysis. Conclusions EUS-FNA performed without on-site cytopathologist was found to be accurate and safe, and thus EUS-FNA should be a part of the standard management algorithm for pancreatic and peripancreatic mass. PMID:20431733
Paksoy, Nadir; Ozbek, Busra
2018-01-01
Over the last few decades, fine needle aspiration cytology (FNA) has emerged as a SAFE (Simple, Accurate, Fast, Economical) diagnostic tool based on the morphologic evaluation of cells. The first and most important step in obtaining accurate results from FNA is to procure sufficient and representative material from the lesion and to appropriately transfer this material to the laboratory. Unfortunately, the most important aspect of this task occurs beyond the control of the cytopathologist, a key reason for obtaining unsatisfactory results with FNA. There is growing interest in the field of cytology in "cytopathologist-performed ultrasound (US)-guided FNA," which has been reported to yield accurate results. The first author has been applying FNA in his own private cytopathology practice with a radiologist and under the guidance of US for more than 20 years. This study retrospectively reviews the utility of this practice. We present a selection of didactic examples under different headings that highlight the application of FNA by a cytopathologist, accompanied by US, under the guidance of a radiologist, in the form of an "outpatient FNA clinic." The use of this technique enhances diagnostic accuracy and prevents pitfalls. The highlights of each case are also outlined as "take-home messages."
Collins, Katrina; Buckley, Tinera; Anderson, Kevin; Karasik, Michael; Ligato, Saverio
2017-01-01
Perivascular epithelioid cell tumors (PEComas) of the pancreas are extremely rare mesenchymal tumors and to our knowledge, only 17 cases have been reported in the English literature to date. We report our experience with a new case of primary pancreatic PEComa diagnosed preoperatively by endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) complemented by tissue cell block and immunohistochemistry. The patient was a 54-year-old female whose chief complaint was intermittent severe right upper quadrant abdominal pain. Computed-tomography (CT) imaging revealed a mass between the head and the body of the pancreas. EUS-FNA smear preparation was obtained but was nondiagnostic. However, examination of the tissue cell block showed sheets of epithelioid cells with abundant eosinophilic cytoplasm and immunohistochemistry studies revealed positivity for both melanocytic (HMB-45 and Melan-A) and smooth muscle markers (actin and desmin). A diagnosis of PEComa was made and an uncomplicated middle pancreatectomy was performed. Our case and review of the literature demonstrates that EUS-FNA complemented with tissue cell block increases cellular yield, improved preoperative diagnostic accuracy, and may assist the surgeon in planning conservative surgical management. Diagn. Cytopathol. 2017;45:59-65. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Mattiussi, Gabriele; Moreno, Carlos
2016-01-01
Proximal Hamstring Tendinopathy-related Sciatic Nerve Entrapment (PHTrSNE) is a neuropathy caused by fibrosis interposed between the semimembranosus tendon and the sciatic nerve, at the level of the ischial tuberosity. Ultrasound-guided Intratissue Percutaneous Electrolysis (US-guided EPI) involves galvanic current transfer within the treatment target tissue (fibrosis) via a needle 0.30 to 0.33 mm in diameter. The galvanic current in a saline solution instantly develops the chemical process of electrolysis, which in turn induces electrochemical ablation of fibrosis. In this article, the interventional procedure is presented in detail, and both the strengths and limits of the technique are discussed. US-guided EPI eliminates the fibrotic accumulation that causes PHTrSNE, without the semimembranosus tendon or the sciatic nerve being directly involved during the procedure. The technique is however of limited use in cases of compression neuropathy. US-guided EPI is a technique that is quick to perform, minimally invasive and does not force the patient to suspend their activities (work or sports) to make the treatment effective. This, coupled to the fact that the technique is generally well-tolerated by patients, supports use of US-guided EPI in the treatment of PHTrSNE.
Nzayisenga, Jean-Baptiste; Shibemba, Aaron; Kusweje, Victor; Chiboola, Hector; Amuyunzu-Nyamongo, Mary; Kapambwe, Sharon; Mwaba, Catherine; Lermontov, Pavlo; Mumba, Chibamba; Henry-Tillman, Ronda; Parham, Groesbeck P.
2018-01-01
Background Long delays to diagnosis is a major cause of late presentation of breast diseases in sub-Saharan Africa. Aims We designed and implemented a single-visit breast care algorithm that overcomes health system-related barriers to timely diagnosis of breast diseases. Methods A multidisciplinary team of Zambian healthcare experts trained a team of mid- and high-level Zambian healthcare practitioners how to evaluate women for breast diseases, and train trainers to do likewise. Working collaboratively, the two teams then designed a clinical platform that provides multiple breast care services within a single visit. The service platform was implemented using a breast outreach camp format, during which breast self-awareness, psychosocial counseling, clinical breast examination, breast ultrasound, ultrasound-guided biopsy, imprint cytology of biopsy specimens and surgical treatment or referral, were offered within a single visit. Results Eleven hundred and twenty-nine (1129) women attended the camps for breast care. Mean age was 35.9 years. The majority were multiparous (79.4%), breast-fed (76.0%), and reported hormone use (50.4%). Abnormalities were detected on clinical breast examination in 122 (10.8%) women, 114 of whom required ultrasound. Of the 114 who underwent ultrasound, 48 had identifiable lesions and were evaluated with ultrasound-guided core needle biopsy (39) or fine-needle aspiration (9). The concordance between imprint cytology and histopathology was 100%, when breast specimens were classified as either benign or malignant. However, when specimens were classified by histopathologic subtype, the concordance between imprint cytology and histology was 85.7% for benign and 100% for malignant lesions. Six (6) women were diagnosed with invasive cancer. Eighteen (18) women with symptomatic breast lesions had next-day surgery. Significance Similar to its impact on cervical cancer prevention services, a single visit breast care algorithm has the potential to overcome health system-related barriers to timely diagnosis of breast diseases, including cancer, in rural African settings. PMID:29746541
Evaluation and nonsurgical management of rotator cuff calcific tendinopathy.
Greis, Ari C; Derrington, Stephen M; McAuliffe, Matthew
2015-04-01
Rotator cuff calcific tendinopathy is a common finding that accounts for about 7% of patients with shoulder pain. There are numerous theories on the pathogenesis of rotator cuff calcific tendinopathy. The diagnosis is confirmed with radiography, MRI or ultrasound. There are numerous conservative treatment options available and most patients can be managed successfully without surgical intervention. Nonsteroidal anti-inflammatory drugs and multiple modalities are often used to manage pain and inflammation; physical therapy can help improve scapular mechanics and decrease dynamic impingement; ultrasound-guided needle aspiration and lavage techniques can provide long-term improvement in pain and function in these patients. Copyright © 2015 Elsevier Inc. All rights reserved.
McCrary, Hilary C; Krate, Jonida; Savilo, Christine E; Tran, Melissa H; Ho, Hang T; Adamas-Rappaport, William J; Viscusi, Rebecca K
2016-11-01
The aim of our study was to determine if a fresh cadaver model is a viable method for teaching ultrasound (US)-guided breast biopsy of palpable breast lesions. Third-year medical students were assessed both preinstruction and postinstruction on their ability to perform US-guided needle aspiration or biopsy of artificially created masses using a 10-item checklist. Forty-one third-year medical students completed the cadaver laboratory as part of the surgery clerkship. Eight items on the checklist were found to be significantly different between pre-testing and post-testing. The mean preinstruction score was 2.4, whereas the mean postinstruction score was 7.10 (P < .001). Fresh cadaver models have been widely used in medical education. However, there are few fresh cadaver models that provide instruction on procedures done in the outpatient setting. Our model was found to be an effective method for the instruction of US-guided breast biopsy among medical students. Copyright © 2016 Elsevier Inc. All rights reserved.
Models to teach lung sonopathology and ultrasound-guided thoracentesis.
Wojtczak, Jacek A
2014-12-01
Lung sonography allows rapid diagnosis of lung emergencies such as pulmonary edema, hemothorax or pneumothorax. The ability to timely diagnose an intraoperative pneumothorax is an important skill for the anesthesiologist. However, lung ultrasound exams require an interpretation of not only real images but also complex acoustic artifacts such as A-lines and B-lines. Therefore, appropriate training to gain proficiency is important. Simulated environment using ultrasound phantom models allows controlled, supervised learning. We have developed hybrid models that combine dry or wet polyurethane foams, porcine rib cages and human hand simulating a rib cage. These models simulate fairly accurately pulmonary sonopathology and allow supervised teaching of lung sonography with the immediate feedback. In-vitro models can also facilitate learning of procedural skills, improving transducer and needle positioning and movement, rapid recognition of thoracic anatomy and hand - eye coordination skills. We described a new model to teach an ultrasound guided thoracentesis. This model consists of the experimenter's hand placed on top of the water-filled container with a wet foam. Metacarpal bones of the human hand simulate a rib cage and a wet foam simulates a diseased lung immersed in the pleural fluid. Positive fluid flow offers users feedback when a simulated pleural effusion is accurately assessed.
Kim, Won Hwa; Kim, Hye Jung; Jung, Jin Hyang; Park, Ho Yong; Lee, Jeeyeon; Kim, Wan Wook; Park, Ji Young; Cheon, Hyejin; Lee, So Mi; Cho, Seung Hyun; Shin, Kyung Min; Kim, Gab Chul
2017-11-01
Ultrasonography-guided fine-needle aspiration (US-guided FNA) for axillary lymph nodes (ALNs) is currently used with various techniques for the initial staging of breast cancer and tagging of ALNs. With the implementation of the tattooing of biopsied ALNs, the rate of false-negative results of US-guided FNA for non-palpable and suspicious ALNs and concordance with sentinel lymph nodes were determined by node-to node analyses. A total of 61 patients with breast cancer had negative results for metastasis on US-guided FNA of their non-palpable and suspicious ALNs. The biopsied ALNs were tattooed with an injection of 1-3 mL Charcotrace (Phebra, Lane Cove West, Australia) ink and removed during sentinel lymph node biopsy or axillary dissection. We determined the rate of false-negative results and concordance with the sentinel lymph nodes by a retrospective review of surgical and pathologic findings. The association of false-negative results with clinical and imaging factors was evaluated using logistic regression. Of the 61 ALNs with negative results for US-guided FNA, 13 (21%) had metastases on final pathology. In 56 of 61 ALNs (92%), tattooed ALNs corresponded to the sentinel lymph nodes. Among the 5 patients (8%) without correspondence, 1 patient (2%) had 2 metastatic ALNs of 1 tattooed node and 1 sentinel lymph node. In multivariate analysis, atypical cells on FNA results (odds ratio = 20.7, p = 0.040) was independently associated with false-negative FNA results. False-negative ALNs after US-guided FNA occur at a rate of 21% and most of the tattooed ALNs showed concordance with sentinel lymph nodes. Copyright © 2017 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Xia, Wenfeng; Nikitichev, Daniil I.; Mari, Jean Martial; West, Simeon J.; Ourselin, Sebastien; Beard, Paul C.; Desjardins, Adrien E.
2015-07-01
Precise and efficient guidance of medical devices is of paramount importance for many minimally invasive procedures. These procedures include fetal interventions, tumor biopsies and treatments, central venous catheterisations and peripheral nerve blocks. Ultrasound imaging is commonly used for guidance, but it often provides insufficient contrast with which to identify soft tissue structures such as vessels, tumors, and nerves. In this study, a hybrid interventional imaging system that combines ultrasound imaging and multispectral photoacoustic imaging for guiding minimally invasive procedures was developed and characterized. The system provides both structural information from ultrasound imaging and molecular information from multispectral photoacoustic imaging. It uses a commercial linear-array ultrasound imaging probe as the ultrasound receiver, with a multimode optical fiber embedded in a needle to deliver pulsed excitation light to tissue. Co-registration of ultrasound and photoacoustic images is achieved with the use of the same ultrasound receiver for both modalities. Using tissue ex vivo, the system successfully discriminated deep-located fat tissue from the surrounding muscle tissue. The measured photoacoustic spectrum of the fat tissue had good agreement with the lipid spectrum in literature.
Conformal needle-based ultrasound ablation using EM-tracked conebeam CT image guidance
NASA Astrophysics Data System (ADS)
Burdette, E. Clif; Banovac, Filip; Diederich, Chris J.; Cheng, Patrick; Wilson, Emmanuel; Cleary, Kevin R.
2011-03-01
Numerous studies have demonstrated the efficacy of interstitial ablative approaches for the treatment of renal and hepatic tumors. Despite these promising results, current systems remain highly dependent on operator skill, and cannot treat many tumors because there is little control of the size and shape of the zone of necrosis, and no control over ablator trajectory within tissue once insertion has taken place. Additionally, tissue deformation and target motion make it extremely difficult to accurately place the ablator device into the target. Irregularly shaped target volumes typically require multiple insertions and several sequential thermal ablation procedures. This study demonstrated feasibility of spatially tracked image-guided conformal ultrasound (US) ablation for percutaneous directional ablation of diseased tissue. Tissue was prepared by suturing the liver within a pig belly and 1mm BBs placed to serve as needle targets. The image guided system used integrated electromagnetic tracking and cone-beam CT (CBCT) with conformable needlebased high-intensity US ablation in the interventional suite. Tomographic images from cone beam CT were transferred electronically to the image-guided tracking system (IGSTK). Paired-point registration was used to register the target specimen to CT images and enable navigation. Path planning is done by selecting the target BB on the GUI of the realtime tracking system and determining skin entry location until an optimal path is selected. Power was applied to create the desired ablation extent within 7-10 minutes at a thermal dose (>300eqm43). The system was successfully used to place the US ablator in planned target locations within ex-vivo kidney and liver through percutaneous access. Targeting accuracy was 3-4 mm. Sectioned specimens demonstrated uniform ablation within the planned target zone. Subsequent experiments were conducted for multiple ablator positions based upon treatment planning simulations. Ablation zones in liver were 73cc, 84cc, and 140cc for 3, 4, and 5 placements, respectively. These experiments demonstrate the feasibility of combining real-time spatially tracked image guidance with directional interstitial ultrasound ablation. Interstitial ultrasound ablation delivered on multiple needles permit the size and shape of the ablation zone to be "sculpted" by modifying the angle and intensity of the active US elements in the array. This paper summarizes the design and development of the first system incorporating thermal treatment planning and integration of a novel interstitial acoustic ablation device with integrated 3D electromagnetic tracking and guidance strategy.
Lee, Wonyou; Song, Kilyoung; Lee, Inhyung; Shin, Hyungdo; Lee, Byeong Chun
2015-01-01
Transvaginal ultrasound-guided follicle aspiration is one method of obtaining recipient oocytes for equine somatic cell nuclear transfer (SCNT). This study was conducted: (1) to evaluate the possibility of oocyte aspiration from pre-ovulatory follicles using a short disposable needle system (14-G) by comparing the oocyte recovery rate with that of a long double lumen needle (12-G); (2) to investigate the developmental competence of recovered oocytes after SCNT and embryo transfer. The recovery rates with the short disposable needle vs. the long needle were not significantly different (47.5% and 35.0%, respectively). Twenty-six SCNT embryos were transferred to 13 mares, and one mare delivered a live offspring at Day 342. There was a perfect identity match between the cloned foal and the cell donor after analysis of microsatellite DNA, and the mitochondrial DNA of the cloned foal was identical with that of the oocyte donor. These results demonstrated that the short disposable needle system can be used to recover oocytes to use as cytoplasts for SCNT, in the production of cloned foals and for other applications in equine embryology PMID:26119166
Azhar, J Khairul; Jacqueline, H S G; Tony, L K H; Tan, B H; Steven, J M
2011-12-01
We report a case of a healthy 78-year-old indonesian man who presented with chronic weight loss, poor appetite and lethargy. CT abdomen showed bilateral adrenal masses. EUS-guided FNA was performed on the left adrenal gland. Histopathology report was Histoplasma Capsulatum. He recovered well with antifungal treatment without any complication. In this case, we found that the role of EUS -guided FNA was not only limited to diagnosis but also helped in the prognosis of the disease since the method was able to assess the general anatomy of the adrenal gland better than other imaging modalities due to its close proximity and direct visualization.
Real-time needle guidance with photoacoustic and laser-generated ultrasound probes
NASA Astrophysics Data System (ADS)
Colchester, Richard J.; Mosse, Charles A.; Nikitichev, Daniil I.; Zhang, Edward Z.; West, Simeon; Beard, Paul C.; Papakonstantinou, Ioannis; Desjardins, Adrien E.
2015-03-01
Detection of tissue structures such as nerves and blood vessels is of critical importance during many needle-based minimally invasive procedures. For instance, unintentional injections into arteries can lead to strokes or cardiotoxicity during interventional pain management procedures that involve injections in the vicinity of nerves. Reliable detection with current external imaging systems remains elusive. Optical generation and reception of ultrasound allow for depth-resolved sensing and they can be performed with optical fibers that are positioned within needles used in clinical practice. The needle probe developed in this study comprised separate optical fibers for generating and receiving ultrasound. Photoacoustic generation of ultrasound was performed on the distal end face of an optical fiber by coating it with an optically absorbing material. Ultrasound reception was performed using a high-finesse Fabry-Pérot cavity. The sensor data was displayed as an M-mode image with a real-time interface. Imaging was performed on a biological tissue phantom.
Interventional robotic systems: Applications and technology state-of-the-art
CLEARY, KEVIN; MELZER, ANDREAS; WATSON, VANCE; KRONREIF, GERNOT; STOIANOVICI, DAN
2011-01-01
Many different robotic systems have been developed for invasive medical procedures. In this article we will focus on robotic systems for image-guided interventions such as biopsy of suspicious lesions, interstitial tumor treatment, or needle placement for spinal blocks and neurolysis. Medical robotics is a young and evolving field and the ultimate role of these systems has yet to be determined. This paper presents four interventional robotics systems designed to work with MRI, CT, fluoroscopy, and ultrasound imaging devices. The details of each system are given along with any phantom, animal, or human trials. The systems include the AcuBot for active needle insertion under CT or fluoroscopy, the B-Rob systems for needle placement using CT or ultrasound, the INNOMOTION for MRI and CT interventions, and the MRBot for MRI procedures. Following these descriptions, the technology issues of image compatibility, registration, patient movement and respiration, force feedback, and control mode are briefly discussed. It is our belief that robotic systems will be an important part of future interventions, but more research and clinical trials are needed. The possibility of performing new clinical procedures that the human cannot achieve remains an ultimate goal for medical robotics. Engineers and physicians should work together to create and validate these systems for the benefits of patients everywhere. PMID:16754193
Elagili, Faisal; Abdullah, Norlia; Fong, Liew; Pei, Tan
2007-01-01
To assess ultrasonographically (US) guided needle aspiration of breast abscesses as an alternative to surgical incision and drainage. In our prospective study, 30 patients with 31 breast abscesses (one patient had bilateral breast abscess) underwent percutaneous breast abscess drainage under US guidance with local anaesthesia and oral antibiotics between 1 January 2004 and 31 March 2005. These patients consisted of 16 (53.3%) non-lactating and 14 (46.7%) lactating women, with ages ranging from 18 to 68 years (median, 28 years). The racial distribution comprised 26 (86.7%) Malays, three (10%) Chinese and one (3.3%) Indian. All patients had the chief complaint of breast swelling and 25 (83.3%) had breast pain. Clinically, 28 (93.3%) were found to have a palpable mass. Nine (30%) lesions were in the upper outer quadrant of the left breast. US diameters ranged from 1 to 15 cm (median, 4 cm). The pus volumes varied from 1 to 200 mL (median, 14 mL). Fifteen (50%) patients required only a single aspiration, 10 required multiple aspirations and five required incision and drainage. Those patients in whom needle aspiration failed had multiloculated lesions irrespective of abscess volume and size. Needle aspiration with ultrasound guidance is an effective treatment for breast abscess irrespective of abscess volume and size.
Lopez, A M; Sala-Blanch, X; Castillo, R; Hadzic, A
2014-01-01
The recommendations for the level of injection and ideal placement of the needle tip required for successful ultrasound-guided sciatic popliteal block vary among authors. A hypothesis was made that, when the local anesthetic is injected at the division of the sciatic nerve within the common connective tissue sheath, the block has a higher success rate than an injection outside the sheath. Thirty-four patients scheduled for hallux valgus repair surgery were randomized to receive either a sub-sheath block (n=16) or a peri-sheath block (n=18) at the level of the division of the sciatic nerve at the popliteal fossa. For the sub-sheath block, the needle was advanced out of plane until the tip was positioned between the tibial and peroneal nerves, and local anesthetic was then injected without moving the needle. For the peri-sheath block, the needle was advanced out of plane both sides of the sciatic nerve, to surround the sheath. Mepivacaine 1.5% and levobupivacaine 0.5% 30mL were used in both groups. The progression of motor and sensory block was assessed at 5min intervals. Duration of block was recorded. Adequate surgical block was achieved in all patients in the subsheath group (100%) compared to 12 patients (67%) in the peri-sheath group at 30min. Sensory block was achieved faster in the subsheath than peri-sheath (9.1±7.4min vs. 19.0±4.0; p<.001). Our study suggests that for successful sciatic popliteal block in less than 30min, local anesthetic should be injected within the sheath. Copyright © 2013 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Published by Elsevier España. All rights reserved.
Zhu, Mengchen; Salcudean, Septimiu E
2011-07-01
In this paper, we propose an interpolation-based method for simulating rigid needles in B-mode ultrasound images in real time. We parameterize the needle B-mode image as a function of needle position and orientation. We collect needle images under various spatial configurations in a water-tank using a needle guidance robot. Then we use multidimensional tensor-product interpolation to simulate images of needles with arbitrary poses and positions using collected images. After further processing, the interpolated needle and seed images are superimposed on top of phantom or tissue image backgrounds. The similarity between the simulated and the real images is measured using a correlation metric. A comparison is also performed with in vivo images obtained during prostate brachytherapy. Our results, carried out for both the convex (transverse plane) and linear (sagittal/para-sagittal plane) arrays of a trans-rectal transducer indicate that our interpolation method produces good results while requiring modest computing resources. The needle simulation method we present can be extended to the simulation of ultrasound images of other wire-like objects. In particular, we have shown that the proposed approach can be used to simulate brachytherapy seeds.
Santamato, Andrea; Micello, Maria Francesca; Valeno, Giovanni; Beatrice, Raffaele; Cinone, Nicoletta; Baricich, Alessio; Picelli, Alessandro; Panza, Francesco; Logroscino, Giancarlo; Fiore, Pietro; Ranieri, Maurizio
2015-01-01
Piriformis muscle syndrome (PMS) is caused by prolonged or excessive contraction of the piriformis muscle associated with pain in the buttocks, hips, and lower limbs because of the close proximity to the sciatic nerve. Botulinum toxin type A (BoNT-A) reduces muscle hypertonia as well as muscle contracture and pain inhibiting substance P release and other inflammatory factors. BoNT-A injection technique is important considering the difficult access of the needle for deep location, the small size of the muscle, and the proximity to neurovascular structures. Ultrasound guidance is easy to use and painless and several studies describe its use during BoNT-A administration in PMS. In the present review article, we briefly updated current knowledge regarding the BoNT therapy of PMS, describing also a case report in which this syndrome was treated with an ultrasound-guided injection of incobotulinumtoxin A. Pain reduction with an increase of hip articular range of motion in this patient with PMS confirmed the effectiveness of BoNT-A injection for the management of this syndrome. PMID:26266421
Automatic needle segmentation in 3D ultrasound images using 3D improved Hough transform
NASA Astrophysics Data System (ADS)
Zhou, Hua; Qiu, Wu; Ding, Mingyue; Zhang, Songgen
2008-03-01
3D ultrasound (US) is a new technology that can be used for a variety of diagnostic applications, such as obstetrical, vascular, and urological imaging, and has been explored greatly potential in the applications of image-guided surgery and therapy. Uterine adenoma and uterine bleeding are the two most prevalent diseases in Chinese woman, and a minimally invasive ablation system using a needle-like RF button electrode is widely used to destroy tumor cells or stop bleeding. To avoid accidents or death of the patient by inaccurate localizations of the electrode and the tumor position during treatment, 3D US guidance system was developed. In this paper, a new automated technique, the 3D Improved Hough Transform (3DIHT) algorithm, which is potentially fast, accurate, and robust to provide needle segmentation in 3D US image for use of 3D US imaging guidance, was presented. Based on the coarse-fine search strategy and a four parameter representation of lines in 3D space, 3DIHT algorithm can segment needles quickly, accurately and robustly. The technique was evaluated using the 3D US images acquired by scanning a water phantom. The segmentation position deviation of the line was less than 2mm and angular deviation was much less than 2°. The average computational time measured on a Pentium IV 2.80GHz PC computer with a 381×381×250 image was less than 2s.
Eom, H-J; Lee, J H; Ko, M-S; Choi, Y J; Yoon, R G; Cho, K J; Nam, S Y; Baek, J H
2015-06-01
Diagnostic test accuracy studies for ultrasonography-guided fine-needle aspiration and ultrasonography-guided core needle biopsy have shown inconclusive results due to their heterogenous study designs. Our aim was to compare the diagnostic accuracy of ultrasonography-guided fine-needle aspiration versus ultrasonography-guided core needle biopsy for detecting malignant tumors of the salivary gland and for the tissue-specific diagnosis of salivary gland tumors in a single tertiary hospital. This retrospective study was approved by our institutional review board and informed consent was waived. Four hundred twelve patients who underwent ultrasonography-guided fine-needle aspiration (n = 155) or ultrasonography-guided core needle biopsy (n = 257) with subsequent surgical confirmation or clinical follow-up were enrolled. We compared the diagnostic accuracy of ultrasonography-guided fine-needle aspiration and ultrasonography-guided core needle biopsy regarding malignant salivary gland tumors and the correct tissue-specific diagnosis of benign and malignant tumors. We also tested the difference between these procedures according to the operator's experience and lesion characteristics. The inconclusive rates of ultrasonography-guided fine-needle aspiration and ultrasonography-guided core needle biopsy were 19% and 4%, respectively (P < .001). The overall accuracy of ultrasonography-guided core needle biopsy for diagnosing malignant tumors was significantly higher than that of ultrasonography-guided fine-needle aspiration (P = .024). The correct tissue-specific diagnosis rates of ultrasonography-guided fine-needle aspiration and ultrasonography-guided core needle biopsy were 95% versus 97% for benign tumors (P = .648) and 67% versus 80% for malignant tumors (P = .310). Trainees showed significantly lower accuracy with ultrasonography-guided fine-needle aspiration than with ultrasonography-guided core needle biopsy for diagnosing malignant tumors (P = .021). There was no difference between the diagnostic accuracy of ultrasonography-guided fine-needle aspiration and ultrasonography-guided core needle biopsy according to the internal composition of the lesions. There were no complications requiring intervention or hospitalization in our patients. Ultrasonography-guided core needle biopsy is superior to ultrasonography-guided fine-needle aspiration in detecting and characterizing malignant tumors of the salivary gland and could emerge as the diagnostic method of choice for patients presenting with a salivary gland mass. © 2015 by American Journal of Neuroradiology.
Endobronchial Ultrasound in Suspected Non-Malignant Mediastinal Lymphadenopathy.
Eickhoff, L; Golpon, H; Zardo, P; Suhling, H; Welte, T; Jonigk, D; Gottlieb, J; Fuehner, T
2018-05-22
Endobronchial ultrasound (EBUS) bronchoscopy with transbronchial needle aspiration (TBNA) is a well-established tool in mediastinal staging in lung cancer and gains importance in exploration of non-malignant lymphadenopathy. The aim of this study was to evaluate the role of EBUS-TBNA in suspected non-malignant diseases. A retrospective, single-center, observation analysis of endobronchial ultrasound bronchoscopy procedures was performed in a university medical center between March 2013 and July 2015. All patients with suspected non-malignant mediastinal lymphadenopathy were included. Cytopathological and microbiological results of EBUS were compared to clinical diagnosis 6 months after procedure and performance of EBUS was contrasted to malignant indications. During study period, 333 EBUS bronchoscopies in 315 patients with mediastinal lymphadenopathy were performed. 111 out of 315 (35 %) patients had neither primary signs nor history of a malignant disease, categorised as patients with suspected non-malignant disease. 245 lymph nodes were sampled (median size 15 mm [IQR10 - 19]). Preferred station for TBNA was lymph node station 7 (38 %). Cytopathological findings revealed non-specific inflammation (n = 81; 70 %), carcinoma (n = 7; 6 %), epithelioid cell granulomas (n = 20; 17 %). 7 samples (6 %) were non-representative. Microbiologic testing of lymph nodes identified 3 infections (Mycobacteria tuberculosis [n = 2] and Nocardia nova [n = 1]) relevant to antibiotic therapy. Minor adverse events were observed in 9 out of 115 (8 %) patients. Sensitivity of EBUS-TBNA intervention in suspected non-malignant disease was 76 % and specificity 96 %. EBUS-TBNA revealed a specific cause for suspected non-malignant lymphadenopathy in one-third of cases and was associated with excellent specificity. Predominant specific causes were granuloma, besides from tumor. In 3 patients pathogen could be isolated by TBNA. © Georg Thieme Verlag KG Stuttgart · New York.
A Prediction Model to Help with the Assessment of Adenopathy in Lung Cancer: HAL.
O'Connell, Oisin J; Almeida, Francisco A; Simoff, Michael J; Yarmus, Lonny; Lazarus, Ray; Young, Benjamin; Chen, Yu; Semaan, Roy; Saettele, Timothy M; Cicenia, Joseph; Bedi, Harmeet; Kliment, Corrine; Li, Liang; Sethi, Sonali; Diaz-Mendoza, Javier; Feller-Kopman, David; Song, Juhee; Gildea, Thomas; Lee, Hans; Grosu, Horiana B; Machuzak, Michael; Rodriguez-Vial, Macarena; Eapen, George A; Jimenez, Carlos A; Casal, Roberto F; Ost, David E
2017-06-15
Estimating the probability of finding N2 or N3 (prN2/3) malignant nodal disease on endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) in patients with non-small cell lung cancer (NSCLC) can facilitate the selection of subsequent management strategies. To develop a clinical prediction model for estimating the prN2/3. We used the AQuIRE (American College of Chest Physicians Quality Improvement Registry, Evaluation, and Education) registry to identify patients with NSCLC with clinical radiographic stage T1-3, N0-3, M0 disease that had EBUS-TBNA for staging. The dependent variable was the presence of N2 or N3 disease (vs. N0 or N1) as assessed by EBUS-TBNA. Univariate followed by multivariable logistic regression analysis was used to develop a parsimonious clinical prediction model to estimate prN2/3. External validation was performed using data from three other hospitals. The model derivation cohort (n = 633) had a 25% prevalence of malignant N2 or N3 disease. Younger age, central location, adenocarcinoma histology, and higher positron emission tomography-computed tomography N stage were associated with a higher prN2/3. Area under the receiver operating characteristic curve was 0.85 (95% confidence interval, 0.82-0.89), model fit was acceptable (Hosmer-Lemeshow, P = 0.62; Brier score, 0.125). We externally validated the model in 722 patients. Area under the receiver operating characteristic curve was 0.88 (95% confidence interval, 0.85-0.90). Calibration using the general calibration model method resulted in acceptable goodness of fit (Hosmer-Lemeshow test, P = 0.54; Brier score, 0.132). Our prediction rule can be used to estimate prN2/3 in patients with NSCLC. The model has the potential to facilitate clinical decision making in the staging of NSCLC.
NASA Astrophysics Data System (ADS)
Nikitichev, Daniil I.; Xia, Wenfeng; West, Simeon J.; Desjardins, Adrien E.; Ourselin, Sebastien; Vercauteren, Tom
2017-03-01
Ultrasound (US) imaging is widely used to guide vascular access procedures such as arterial and venous cannulation. As needle visualisation with US imaging can be very challenging, it is easy to misplace the needle in the patient and it can be life threating. Photoacoustic (PA) imaging is well suited to image medical needles and catheters that are commonly used for vascular access. To improve the success rate, a certain level of proficiency is required that can be gained through extensive practice on phantoms. Unfortunately, commercial training phantoms are expensive and custom-made phantoms usually do not replicate the anatomy very well. Thus, there is a great demand for more realistic and affordable ultrasound and photoacoustic imaging phantoms for vasculature access procedures training. Three-dimensional (3D) printing can help create models that replicate complex anatomical geometries. However, the available 3D printed materials do not possess realistic tissue properties. Alternatively, tissue-mimicking materials can be employed using casting and 3D printed moulds but this approach is limited to the creation of realistic outer shapes with no replication of complex internal structures. In this study, we developed a realistic vasculature access phantom using a combination of mineral oil based materials as background tissue and a non-toxic, water dissolvable filament material to create complex vascular structure using 3D printing. US and PA images of the phantoms comprising the complex vasculature network were acquired. The results show that 3D printing can facilitate the fabrication of anatomically realistic training phantoms, with designs that can be customized and shared electronically.
Pillai, Anil K; Andring, Brice; Faulconer, Nicholas; Reis, Stephen P; Xi, Yin; Iyamu, Ikponmwosa; Suthpin, Patrick D; Kalva, Sanjeeva P
2016-08-01
To compare safety and effectiveness of intravascular ultrasound (US)-guided portal vein access during transjugular intrahepatic portosystemic shunt (TIPS) creation with conventional TIPS technique. In this retrospective study, TIPS creation using intravascular US guidance in 55 patients was compared with conventional TIPS creation in 54 patients by 10 operators over a 3-year period. Operators were classified as experienced if they had performed ≥ 20 TIPS procedures at the beginning of the study period. Time to portal vein access, total radiation dose, and needle pass-related capsular perforation were recorded. Baseline demographic characteristics of patients were similar (P > .05). Mean time to portal venous access was 46 minutes ± 37 for conventional TIPS and 31 minutes ± 19 for intravascular US-guided TIPS (P = .007). Intravascular US guidance allowed significantly shorter times (48 min ± 30 vs 28 min ± 16; P = .01) to portal vein access among operators (n = 5) with limited experience but failed to achieve any significant time savings (44 min ± 43 vs 34 min ± 22; P = .89) among experienced operators (n = 5). Needle pass-related capsular perforation occurred in 17/54 (34%) patients with conventional TIPS and 5/55 (9%) patients with intravascular US-guided TIPS (P = .004). Radiation dose was 2,376 mGy ± 1,816 for conventional TIPS and 1,592 mGy ± 1,263 for intravascular US-guided TIPS (P = .004). Intravascular US-guided portal vein access during TIPS creation is associated with shorter portal vein access times, decreased needle pass-related capsular perforations, and reduced radiation dose. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.
Singaporewalla, R M; Hwee, J; Lang, T U; Desai, V
2017-07-01
Clinico-pathological correlation of thyroid nodules is not routinely performed as until recently there was no objective classification system for reporting thyroid nodules on ultrasound. We compared the Thyroid Imaging Reporting and Data System (TIRADS) of classifying thyroid nodules on ultrasound with the findings on fine-needle aspiration cytology (FNAC) reported using the Bethesda System. A retrospective analysis of 100 consecutive cases over 1 year (Jan-Dec 2015) was performed comparing single-surgeon-performed bedside thyroid nodule ultrasound findings based on the TIRADS classification to the FNAC report based on the Bethesda Classification. TIRADS 1 (normal thyroid gland) and biopsy-proven malignancy referred by other clinicians were excluded. Benign-appearing nodules were reported as TIRADS 2 and 3. Indeterminate or suspected follicular lesions were reported as TIRADS 4, and malignant-appearing nodules were classified as TIRADS 5 during surgeon-performed bedside ultrasound. All the nodules were subjected to ultrasound-guided FNAC, and TIRADS findings were compared to Bethesda FNAC Classification. Of the 100 cases, 74 were considered benign or probably benign, 20 were suspicious for malignancy, and 6 were indeterminate on ultrasound. Overall concordance rate with FNAC was 83% with sensitivity and specificity of 70.6 and 90.4%, respectively. The negative predictive value was 93.8%. It is essential for clinicians performing bedside ultrasound thyroid and guided FNAC to document their sonographic impression of the nodule in an objective fashion using the TIRADS classification and correlate with the gold standard cytology to improve their learning curve and audit their results.
Endoscopic ultrasound guided fine needle aspiration and useful ancillary methods
Tadic, Mario; Stoos-Veic, Tajana; Kusec, Rajko
2014-01-01
The role of endoscopic ultrasound (EUS) in evaluating pancreatic pathology has been well documented from the beginning of its clinical use. High spatial resolution and the close proximity to the evaluated organs within the mediastinum and abdominal cavity allow detection of small focal lesions and precise tissue acquisition from suspected lesions within the reach of this method. Fine needle aspiration (FNA) is considered of additional value to EUS and is performed to obtain tissue diagnosis. Tissue acquisition from suspected lesions for cytological or histological analysis allows, not only the differentiation between malignant and non-malignant lesions, but, in most cases, also the accurate distinction between the various types of malignant lesions. It is well documented that the best results are achieved only if an adequate sample is obtained for further analysis, if the material is processed in an appropriate way, and if adequate ancillary methods are performed. This is a multi-step process and could be quite a challenge in some cases. In this article, we discuss the technical aspects of tissue acquisition by EUS-guided-FNA (EUS-FNA), as well as the role of an on-site cytopathologist, various means of specimen processing, and the selection of the appropriate ancillary method for providing an accurate tissue diagnosis and maximizing the yield of this method. The main goal of this review is to alert endosonographers, not only to the different possibilities of tissue acquisition, namely EUS-FNA, but also to bring to their attention the importance of proper sample processing in the evaluation of various lesions in the gastrointestinal tract and other accessible organs. All aspects of tissue acquisition (needles, suction, use of stylet, complications, etc.) have been well discussed lately. Adequate tissue samples enable comprehensive diagnoses, which answer the main clinical questions, thus enabling targeted therapy. PMID:25339816
Soh, Jae Seung; Lee, Ho-Su; Lee, Seohyun; Bae, Jungho; Lee, Hyo Jeong; Park, Sang Hyoung; Yang, Dong-Hoon; Kim, Kyung-Jo; Ye, Byong Duk; Myung, Seung-Jae; Yang, Suk-Kyun; Kim, Jin-Ho
2015-01-01
Background/Aims Endoscopic ultrasound-guided fine needle aspiration and/or biopsy (EUS-FNA/B) have been used to diagnose subepithelial tumors (SETs) and extraluminal lesions in the gastrointestinal tract. Our group previously reported the usefulness of EUS-FNA/B for rectal and perirectal lesions. This study reports our expanded experience with EUS-FNA/B for rectal and perirectal lesions in terms of diagnostic accuracy and safety. We also included our new experience with EUS-FNB using the recently introduced ProCore needle. Methods From April 2009 to March 2014, EUS-FNA/B for rectal and perirectal lesions was performed in 30 consecutive patients. We evaluated EUS-FNA/B performance by comparing histological diagnoses with final results. We also investigated factors affecting diagnostic accuracy. Results Among 10 patients with SETs, EUS-FNA/B specimen results revealed a gastrointestinal stromal tumor in 4 patients and malignant lymphoma in 1 patient. The diagnostic accuracy of EUS-FNA/B was 50% for SETs (5/10). Among 20 patients with non-SET lesions, 8 patients were diagnosed with malignant disease and 7 were diagnosed with benign disease based on both EUS-FNA/B and the final results. The diagnostic accuracy of EUS-FNA/B for non-SET lesions was 75% (15/20). The size of lesions was the only factor related to diagnostic accuracy (P=0.027). Two complications of mild fever and asymptomatic pneumoperitoneum occurred after EUS-FNA/B. Conclusions The overall diagnostic accuracy of EUS-FNA/B for rectal and perirectal lesions was 67% (20/30). EUS-FNA/B is a clinically useful method for cytological and histological diagnoses of rectal and perirectal lesions. PMID:25931998
Martin, E J; Cooke, E J; Ceponis, A; Barnes, R F W; Moran, C M; Holle, S; Hughes, T H; Moore, R E; von Drygalski, A
2017-01-01
Intra-articular corticosteroid injections are standard of care for managing joint pain secondary to osteoarthritis or rheumatoid arthritis but are rarely used in haemophilic arthropathy. We have introduced and evaluated the efficacy and safety of ultrasound-guided corticosteroid injections for pain relief in patients with haemophilic arthropathy. Ultrasound-guided intra-articular injections performed on haemophilia patients at UCSD between March 2012 and January 2016 were analysed. Needle placement and injection (40 mg triamcinolone; 3-5 mL lidocaine) were performed with musculoskeletal ultrasound and Power Doppler. Analysis included patient demographics, joint-specific parameters such as tissue hypervascularity and effusions, pain relief, and procedure-associated complications. Forty-five injections (14 ankles, 13 elbows, 18 knees) were administered in 25 patients. Advanced arthropathy with hypervascularity and/or effusions was present in 91% and 61% of joints, respectively. Ninety-one per cent of injections resulted in pain relief which was significant in 84% (>30% reduction). Median pain score was reduced from 7 of 10 to 1 of 10 (P < 0.001), usually within 24 h. Median duration of pain relief was 8 weeks (range 1-16 weeks). Haemophilia B patients experienced longer periods of relief, and high Pettersson scores were associated with shorter duration of relief. There were no procedure-associated complications. Repeat ultrasound of eight joints within 4 weeks of injection demonstrated nearly complete resolution of hypervascularity. Point-of-care ultrasound enabled intra-articular corticosteroid injections that provided highly effective, safe, and relatively long-lasting pain relief in haemophilic arthropathy. This approach should be used to improve pain management in haemophilic arthropathy. © 2016 John Wiley & Sons Ltd.
Teleoperation of steerable flexible needles by combining kinesthetic and vibratory feedback.
Pacchierotti, Claudio; Abayazid, Momen; Misra, Sarthak; Prattichizzo, Domenico
2014-01-01
Needle insertion in soft-tissue is a minimally invasive surgical procedure that demands high accuracy. In this respect, robotic systems with autonomous control algorithms have been exploited as the main tool to achieve high accuracy and reliability. However, for reasons of safety and responsibility, autonomous robotic control is often not desirable. Therefore, it is necessary to focus also on techniques enabling clinicians to directly control the motion of the surgical tools. In this work, we address that challenge and present a novel teleoperated robotic system able to steer flexible needles. The proposed system tracks the position of the needle using an ultrasound imaging system and computes needle's ideal position and orientation to reach a given target. The master haptic interface then provides the clinician with mixed kinesthetic-vibratory navigation cues to guide the needle toward the computed ideal position and orientation. Twenty participants carried out an experiment of teleoperated needle insertion into a soft-tissue phantom, considering four different experimental conditions. Participants were provided with either mixed kinesthetic-vibratory feedback or mixed kinesthetic-visual feedback. Moreover, we considered two different ways of computing ideal position and orientation of the needle: with or without set-points. Vibratory feedback was found more effective than visual feedback in conveying navigation cues, with a mean targeting error of 0.72 mm when using set-points, and of 1.10 mm without set-points.
[Interest of ultrasonographic guidance in paediatric regional anaesthesia].
Dadure, C; Raux, O; Rochette, A; Capdevila, X
2009-10-01
The use of ultrasonographic guidance for regional anaesthesia has known recently a big interest in children in recent years. The linear ultrasound probes with a 25 mm active surface area (or probes with 38 mm active surface area in older children), with high sound frequencies in the range 8-14 MHz, allow a good compromise between excellent resolution for superficial structure and good penetration depths. In children, the easiest ultrasound guided blocks are axillar blocks, femoral blocks, fascia iliaca compartment blocks, ilio-inguinal blocks and para-umbilical blocks, caudal blocks. They permit a safe and easy learning curve of these techniques. The main advantage of ultrasound guided regional anaesthesia is the visualization of different anatomical structures and the approximate localization of the tip of needle. The other advantages for ultrasound guided peripheral nerve blocks in children are: faster onset time of sensory and motor block, longer duration of sensory blockade, increase of blockade quality and reduction of local anesthetic injection. The use of ultrasonographic guidance for central block allows to visualize different structures as well as spine and his content. Spinous process, ligament flavum, dura mater, conus medullaris and cerebrospinal fluid are identifiable, and give some information on spine, epidural space and the depth between epidural space and skin. At last, in caudal block, ultrasounds permit to evaluate the anatomy of caudal epidural space, especially the relation of the sacral hiatus to the dural sac and the search of occult spinal dysraphism. Benefit of this technique is the visualization of targeted nerves or spaces and the spread of injected local anaesthetic.
Arias-Buría, José L.; Truyols-Domínguez, Sebastián; Valero-Alcaide, Raquel; Salom-Moreno, Jaime; Atín-Arratibel, María A.; Fernández-de-las-Peñas, César
2015-01-01
Objective. To compare effects of ultrasound- (US-) guided percutaneous electrolysis combined with an eccentric exercise program of the rotator cuff muscles in subacromial pain syndrome. Methods. Thirty-six patients were randomized and assigned into US-guided percutaneous electrolysis (n = 17) group or exercise (n = 19) group. Patients were asked to perform an eccentric exercise program of the rotator cuff muscles twice every day for 4 weeks. Participants assigned to US-guided percutaneous electrolysis group also received the application of galvanic current through acupuncture needle on each session once a week (total 4 sessions). Shoulder pain (NPRS) and disability (DASH) were assessed at baseline, after 2 sessions, and 1 week after the last session. Results. The ANOVA revealed significant Group∗Time interactions for shoulder pain and disability (all, P < 0.01): individuals receiving US-guided percutaneous electrolysis combined with the eccentric exercises experienced greater improvement than those receiving eccentric exercise alone. Conclusions. US-guided percutaneous electrolysis combined with eccentric exercises resulted in small better outcomes at short term compared to when only eccentric exercises were applied in subacromial pain syndrome. The effect was statistically and clinically significant for shoulder pain but below minimal clinical difference for function. Future studies should investigate the long-term effects and potential placebo effect of this intervention. PMID:26649058
Mattiussi, Gabriele; Moreno, Carlos
2016-01-01
Summary Background Proximal Hamstring Tendinopathy-related Sciatic Nerve Entrapment (PHTrSNE) is a neuropathy caused by fibrosis interposed between the semimembranosus tendon and the sciatic nerve, at the level of the ischial tuberosity. Methods Ultrasound-guided Intratissue Percutaneous Electrolysis (US-guided EPI) involves galvanic current transfer within the treatment target tissue (fibrosis) via a needle 0.30 to 0.33 mm in diameter. The galvanic current in a saline solution instantly develops the chemical process of electrolysis, which in turn induces electrochemical ablation of fibrosis. In this article, the interventional procedure is presented in detail, and both the strengths and limits of the technique are discussed. Results US-guided EPI eliminates the fibrotic accumulation that causes PHTrSNE, without the semimembranosus tendon or the sciatic nerve being directly involved during the procedure. The technique is however of limited use in cases of compression neuropathy. Conclusion US-guided EPI is a technique that is quick to perform, minimally invasive and does not force the patient to suspend their activities (work or sports) to make the treatment effective. This, coupled to the fact that the technique is generally well-tolerated by patients, supports use of US-guided EPI in the treatment of PHTrSNE. PMID:27900300
Diego, Rodrigo; Douet, Cécile; Reigner, Fabrice; Blard, Thierry; Cognié, Juliette; Deleuze, Stefan; Goudet, Ghylène
2016-10-15
Transvaginal ultrasound-guided follicular punctures are widely used in the mare for diagnosis, research, and commercial applications. The objective of our study was to determine their influence on pain, stress, and well-being in the mare, by evaluating heart rate, breath rate, facial expression changes, and salivary cortisol before, during, and after puncture. For this experiment, 21 pony mares were used. Transvaginal ultrasound-guided aspirations were performed on 11 mares. After injections for sedation, analgesia, and antispasmodia, the follicles from both ovaries were aspirated with a needle introduced through the vagina wall into the ovary. In the control group, 10 mares underwent similar treatments and injections, but no follicular aspiration. Along the session, heart rate and breath rate were evaluated by a trained veterinarian, ears position, eyelid closure, and contraction of facial muscles were evaluated, and salivary samples were taken for evaluation of cortisol concentration. A significant relaxation was observed after sedative injection in the punctured and control mares, according to ear position, eyelid closure, and contraction of facial muscles, but no difference between punctured and control animals was recorded. No significant modification of salivary cortisol concentration during puncture and no difference between punctured and control mares at any time were observed. No significant modification of the breath rate was observed along the procedure for the punctured and the control mares. Heart rate increased significantly but transiently when the needle was introduced in the ovary and was significantly higher at that time for the punctured mares than that for control mares. None of the other investigated parameters were affected at that time, suggesting discomfort is minimal and transient. Improving analgesia, e.g., through a multimodal approach, during that possibly more sensitive step could be recommended. The evaluation of facial expression changes and heart rate is easy-to-use and accurate tools to evaluate pain and well-being of the mare. Copyright © 2016 Elsevier Inc. All rights reserved.
Rossa, Carlos; Sloboda, Ron; Usmani, Nawaid; Tavakoli, Mahdi
2016-07-01
This paper proposes a method to predict the deflection of a flexible needle inserted into soft tissue based on the observation of deflection at a single point along the needle shaft. We model the needle-tissue as a discretized structure composed of several virtual, weightless, rigid links connected by virtual helical springs whose stiffness coefficient is found using a pattern search algorithm that only requires the force applied at the needle tip during insertion and the needle deflection measured at an arbitrary insertion depth. Needle tip deflections can then be predicted for different insertion depths. Verification of the proposed method in synthetic and biological tissue shows a deflection estimation error of [Formula: see text]2 mm for images acquired at 35 % or more of the maximum insertion depth, and decreases to 1 mm for images acquired closer to the final insertion depth. We also demonstrate the utility of the model for prostate brachytherapy, where in vivo needle deflection measurements obtained during early stages of insertion are used to predict the needle deflection further along the insertion process. The method can predict needle deflection based on the observation of deflection at a single point. The ultrasound probe can be maintained at the same position during insertion of the needle, which avoids complications of tissue deformation caused by the motion of the ultrasound probe.
Samosky, Joseph T; Allen, Pete; Boronyak, Steve; Branstetter, Barton; Hein, Steven; Juhas, Mark; Nelson, Douglas A; Orebaugh, Steven; Pinto, Rohan; Smelko, Adam; Thompson, Mitch; Weaver, Robert A
2011-01-01
We are developing a simulator of peripheral nerve block utilizing a mixed-reality approach: the combination of a physical model, an MRI-derived virtual model, mechatronics and spatial tracking. Our design uses tangible (physical) interfaces to simulate surface anatomy, haptic feedback during needle insertion, mechatronic display of muscle twitch corresponding to the specific nerve stimulated, and visual and haptic feedback for the injection syringe. The twitch response is calculated incorporating the sensed output of a real neurostimulator. The virtual model is isomorphic with the physical model and is derived from segmented MRI data. This model provides the subsurface anatomy and, combined with electromagnetic tracking of a sham ultrasound probe and a standard nerve block needle, supports simulated ultrasound display and measurement of needle location and proximity to nerves and vessels. The needle tracking and virtual model also support objective performance metrics of needle targeting technique.
Yang, Yongtao; Li, Lianyong; Qu, Changmin; Liang, Shuwen; Zeng, Bolun; Luo, Zhiwen
2016-01-01
Endoscopic ultrasound-guided fine needle core biopsy (EUS-FNB) has been used as an effective method of diagnosing pancreatic malignant lesions. It has the advantage of providing well preserved tissue for histologic grading and subsequent molecular biological analysis. In order to estimate the diagnostic accuracy of EUS-FNB for pancreatic malignant lesions, studies assessing EUS-FNB to diagnose solid pancreatic masses were selected via Medline. Sixteen articles published between 2005 and 2015, covering 828 patients, met the inclusion criteria. The summary estimates for EUS-FNB differentiating malignant from benign solid pancreatic masses were: sensitivity 0.84 (95% confidence interval (CI), 0.82–0.87); specificity 0.98 (95% CI, 0.93–1.00); positive likelihood ratio 8.0 (95% CI 4.5–14.4); negative likelihood ratio 0.17 (95% CI 0.10–0.26); and DOR 64 (95% CI 30.4–134.8). The area under the sROC curve was 0.96. Subgroup analysis did not identify other factors that could substantially affect the diagnostic accuracy, such as the study design, location of study, number of centers, location of lesion, whether or not a cytopathologist was present, and so on. EUS-FNB is a reliable diagnostic tool for solid pancreatic masses and should be especially considered for pathology where histologic morphology is preferred for diagnosis. PMID:26960914
Qin, Shan-yu; Zhou, You; Li, Ping; Jiang, Hai-xing
2014-01-01
Background The diagnostic efficiency of endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) cytology varies widely depending on the treatment method of the specimens. The present study aimed to evaluate the diagnostic efficacy of cell block (CB) immunohistochemistry, smear cytology (SC), and liquid-based cytology (LBC) in patients with pancreatic lesions without consulting an on-site cytopathologist. Methods This study prospectively enrolled 72 patients with pancreatic lesions. The EUS-FNA specimens were examined by SC, LBC, and CB immunohistochemistry. The diagnostic efficacy of the 3 methods was then compared. Patients’ final diagnosis was confirmed by surgical resection specimens, diagnostic imaging, and clinical follow-up. Results Our results included 60 malignant and 12 benign pancreatic lesions. The diagnostic sensitivity (90%), negative predictive value (66.7%), and accuracy (91.7%) of CB immunohistochemistry were significantly higher than those of SC (70.0%, 30.0%, and 75.0%, respectively) and LBC (73.3%, 31.6%, and 77.8%, respectively) (all P<0.05). The combination of CB and SC, or CB and LBC, did not significantly increase the efficacy compared to CB immunohistochemistry alone. Conclusion Our findings suggest that in the absence of an on-site cytopathologist, CB immunohistochemistry on EUS-FNA specimens offers a higher diagnostic efficacy in patients with pancreatic lesions than does SC and LBC. PMID:25259861
Bellantone, Rocco; Lombardi, Celestino Pio; Raffaelli, Marco; Traini, Emanuela; De Crea, Carmela; Rossi, Esther Diana; Fadda, Guido
2004-01-01
Conventional fine-needle aspiration biopsy (FNAB) for cystic thyroid nodules (CTNs) has a high rate of nondiagnostic and false-negative results. Ultrasound-guided FNAB (UG-FNAB) permits direct sampling of the wall and/or the solid portion of CTNs, increasing the possibility of a representative sample. In this study we evaluated the role of UG-FNAB in CTNs management. Five-hundred-seventy-five UG-FNAB of CTNs were performed. Thyroidectomy was carried out in 119 of these cases. The medical records of these 119 patients were reviewed and form the basis of this report. The nondiagnostic smear rate was 9.2%. Cytological diagnosis was benign nodule in 42 cases, predominantly follicular lesion in 50 cases, and suspicious or malignant lesion in 16 cases. The final pathology revealed a benign nodule in 98 cases (82.4%) and a carcinoma in 21 (17.6%). The overall accuracy of UG-FNAB was 88.0%. No significant differences were found in age, sex, lesion size, or echographic pattern (p = NS) comparing patients with benign CTNs to patients with malignant CTNs. UG-FNAB has a low rate of nondiagnostic smears and a high overall accuracy in CTNs. All CTNs should undergo UG-FNAB to select patients for surgery, since the malignancy rate is not negligible and no clinical parameter can reliably predict it.
Endoscopic ultrasound guided brush/fine-needle aspiration cytology: A 15-month study.
Tummidi, Santosh; Kothari, Kanchan; Sathe, Pragati; Agnihotri, Mona; Fernandes, Gwendolyn; Naik, Leena; Jain, Aleena; Chaturvedi, Rachana
2018-06-01
Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) has become increasingly popular for the diagnosis and staging of gastrointestinal diseases and peri-gastrointestinal lesions. The application of FNA/Brush has dramatically expanded the clinical utility of EUS. To evaluate the diagnostic accuracy, study the spectrum of lesions encountered in EUS-FNAC/brush cytology of gastrointestinal and peri-gastrointestinal lesions. Total of 124 patients during the period from August 2015 to November 2016 was included in the study. Routine staining was done. A total of 124 cases were studied with 86% (107 cases) being satisfactory for evaluation. M:F ratio was 1:1.03, mean age of 50.5 years. The most common site was common bile duct (CBD) (37%) followed by lymph node (21%), pancreas (17.7%), esophagus (17%), stomach (3.5%), liver (1.8%), gallbladder (1%), and spleen (1%). In total, 53.4% lesions were benign, in 6.5% atypical cells were seen, 12.1% were suspicious for malignancy, and 28% cases were positive for malignancy. Follow-up was available in 102 cases with cyto-histopathological concordance rate of 90%. EUS-FNA/Brush is a reliable, sensitive, specific and minimally invasive way to establish a diagnosis. It can be utilized as a pre-operative procedure for the management of many intra-abdominal lesions and prevent unnecessary invasive procedures. © 2018 Wiley Periodicals, Inc.
BiopSee® - transperineal stereotactic navigated prostate biopsy.
Zogal, Pawel; Sakas, Georgios; Rösch, Woerner; Baltas, Dimos
2011-06-01
In the recent years, prostate cancer was the most commonly diagnosed cancer in men. Currently secure diagnosis confirmation is done by a transrectal biopsy and following histopathological examination. Conventional transrectal biopsy success rates are rather low with ca. 30% detection upon the first and ca 20% after re-biopsy. The paper presents a novel system for stereotactic navigated prostate biopsy. The approach results into higher accuracy, reproducibility and unrestricted and effective access to all prostate regions. Custom designed ultrasound, new template design and integrated 2-axes stepper allows superior 2D and 3D prostate imaging quality and precise needle navigation. DICOM functionality and image fusion enable to import pre-operative datasets (e.g. multiparametric MRI, targets etc.) and overlay all available radiological information into the biopsy planning and guiding procedure. The biopsy needle insertion itself is performed under augmented reality ultrasound guidance. Each procedure step is automatically documented in order to provide quality assurance and permit data re-usage for the further treatment. First clinical results indicates success rates of ca. 70% by first biopsies by our approach.
Pi, Z B; Lin, H; He, G D; Cai, Z; Xu, X Z
2015-01-01
To evaluate the efficacy of ultrasound-guided spinal nerve posterior ramus pulsed radiofrequency treatment for lower back post-herpetic neuralgia. 128 cases of lower back or anterior abdominal wall acute post-herpetic neuralgia patients were selected. They were randomly divided into two groups. Group A: oral treatment only with gabapentin + celecoxib + amitriptyline. Group B: while taking these drugs, patients were treated with radiofrequency (RF) pulses using a portable ultrasound device using the paravertebral puncture technique. In both groups, sudden outbreaks of pain were treated with immediate release 10mg morphine tablets. Visual analogue scale (VAS) was used for pain score, Pittsburgh Sleep Quality Index scale (PSQI) was used to evaluate sleep quality and morphine consumption were recorded at different time points, before and after treatment. Treatment efficiency was calculated while the occurrence of complications was documented. At each time point after treatment, VAS scores were lower, but scores in the RF group was significantly lower than those of the oral-only group. In terms of sleep quality scores and morphine consumption between the two groups, the RF group was significantly lower than the oral-only group. During the procedure no error occurred with needle penetrating the abdominal cavity, chest, offal or blood vessels. Ultrasound-guided spinal nerve posterior ramus pulsed radiofrequency treatment of lower back or anterior abdominal wall post-herpetic neuralgia proved effective by reducing morphine use in patients and led to fewer adverse reactions.
Ince, Ilker; Arı, Muhammet Ali; Sulak, Muhammet Mustafa; Aksoy, Mehmet
There are different ultrasound probe positions used for internal jugular venous catheter placement. Also, in-plane or out of plane needle approach may be used for catheterization. Transverse short-axis classic approach is the most popular performed approach in literature. "Syringe-Free" is a new described technique that is performed with oblique long-axis approach. We aimed to compare performance of these two approaches. This study was conducted as a prospective and randomized study. 80 patients were included the study and divided into two groups that were named Group C (transverse short-axis classic approach) and Group SF (oblique long-axis syringe-free approach) by a computer-generated randomization. The primary outcome was mean time that guidewire is seen in the internal jugular vein (performing time). The secondary outcomes were to compare number of needle pass, number of skin puncture and complications between two groups. Demographic and hemodynamic data were not significantly different. The mean performing time was 54.9±19.1s in Group C and 43.9±15.8s in Group SF. Significant differences were found between the groups (p=0.006). Mean number of needle pass was 3.2(±2.1) in Group C and 2.1(±1.6) in Group SF. There were statistically significant differences between two groups (p=0.002). The number of skin puncture was 1.6(±0.8) and 1.2(±0.5) in Group C and SF, respectively (p=0.027). "Syringe-Free" technique has lower performing time, number of needle pass and skin puncture. Also, it allows to follow progress of guide-wire under continuous ultrasound visualization and the procedure does not need assistance during catheter insertion. Namely, "Syringe-Free" is effective, safe and fast technique that may be used to place internal jugular venous catheter. Copyright © 2017 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All rights reserved.
Zheng, Dandan; Todor, Dorin A
2011-01-01
In real-time trans-rectal ultrasound (TRUS)-based high-dose-rate prostate brachytherapy, the accurate identification of needle-tip position is critical for treatment planning and delivery. Currently, needle-tip identification on ultrasound images can be subject to large uncertainty and errors because of ultrasound image quality and imaging artifacts. To address this problem, we developed a method based on physical measurements with simple and practical implementation to improve the accuracy and robustness of needle-tip identification. Our method uses measurements of the residual needle length and an off-line pre-established coordinate transformation factor, to calculate the needle-tip position on the TRUS images. The transformation factor was established through a one-time systematic set of measurements of the probe and template holder positions, applicable to all patients. To compare the accuracy and robustness of the proposed method and the conventional method (ultrasound detection), based on the gold-standard X-ray fluoroscopy, extensive measurements were conducted in water and gel phantoms. In water phantom, our method showed an average tip-detection accuracy of 0.7 mm compared with 1.6 mm of the conventional method. In gel phantom (more realistic and tissue-like), our method maintained its level of accuracy while the uncertainty of the conventional method was 3.4mm on average with maximum values of over 10mm because of imaging artifacts. A novel method based on simple physical measurements was developed to accurately detect the needle-tip position for TRUS-based high-dose-rate prostate brachytherapy. The method demonstrated much improved accuracy and robustness over the conventional method. Copyright © 2011 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
Venous catheterization with ultrasound navigation
NASA Astrophysics Data System (ADS)
Kasatkin, A. A.; Urakov, A. L.; Nigmatullina, A. R.
2015-11-01
By ultrasound scanning it was determined that respiratory movements made by chest of healthy and sick person are accompanied by respiratory chest rise of internal jugular veins. During the exhalation of an individual diameter of his veins increases and during the breath it decreases down to the complete disappearing if their lumen. Change of the diameter of internal jugular veins in different phases can influence significantly the results of vein puncture and cauterization in patients. The purpose of this research is development of the method increasing the efficiency and safety of cannulation of internal jugular veins by the ultrasound visualization. We suggested the method of catheterization of internal jugular veins by the ultrasound navigation during the execution of which the puncture of venous wall by puncture needle and the following conduction of J-guide is carried out at the moment of patient's exhalation. This method decreases the risk of complications development during catheterization of internal jugular vein due to exclusion of perforating wound of vein and subjacent tissues and anatomical structures.
The role of ultrasonography in the management of lung and pleural diseases.
Rumende, C Martin
2012-04-01
Ultrasonographic examination in pulmonology provides a revolutionary advance because it is very helpful in the diagnosis and management of various pleural and peripheral pulmonary defects. Lung ultrasonography allows the clinicians to diagnose some pulmonary abnormalities more rapidly, including the diagnosis of pleural effusion. Ultrasound examination also provides great assistance for the clinicians to perform invasive techniques in the field of pulmonology, which may increase the success rate and reduce the likelihood of complications. In addition to pleural effusion, other lung disorders can be diagnosed by ultrasound such as peripheral lung tumors and other pleural abnormalities caused by pleural fibrosis and tumor metastasis as well as the primary pleural tumor (mesothelioma). Ultrasound-guided invasive procedures include aspiration of minimal effusion, Transthoracal Needle Aspiration, Transthoracal biopsies and chest tube insertion. Lung ultrasound also offers other advantages, i.e. free from radiation hazards, portable, non-invasive and relatively inexpensive. Ultrasonography in the thorax also has its limitations, especially in detecting mediastinal abnormalities.
Venous catheterization with ultrasound navigation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kasatkin, A. A., E-mail: ant-kasatkin@yandex.ru; Nigmatullina, A. R.; Urakov, A. L., E-mail: ant-kasatkin@yandex.ru
By ultrasound scanning it was determined that respiratory movements made by chest of healthy and sick person are accompanied by respiratory chest rise of internal jugular veins. During the exhalation of an individual diameter of his veins increases and during the breath it decreases down to the complete disappearing if their lumen. Change of the diameter of internal jugular veins in different phases can influence significantly the results of vein puncture and cauterization in patients. The purpose of this research is development of the method increasing the efficiency and safety of cannulation of internal jugular veins by the ultrasound visualization.more » We suggested the method of catheterization of internal jugular veins by the ultrasound navigation during the execution of which the puncture of venous wall by puncture needle and the following conduction of J-guide is carried out at the moment of patient’s exhalation. This method decreases the risk of complications development during catheterization of internal jugular vein due to exclusion of perforating wound of vein and subjacent tissues and anatomical structures.« less
Hohenforst-Schmidt, Wolfgang; Zarogoulidis, Paul; Vogl, Thomas; Turner, J Francis; Browning, Robert; Linsmeier, Bernd; Huang, Haidong; Li, Qiang; Darwiche, Kaid; Freitag, Lutz; Simoff, Michael; Kioumis, Ioannis; Zarogoulidis, Konstantinos; Brachmann, Johannes
2014-01-01
Currently there are several advanced guiding techniques for pathoanatomical diagnosis of incidental solitary pulmonary nodules (iSPN): Electromagnetic navigation (EMN) with or without endobronchial ultrasound (EBUS) with miniprobe, transthoracic ultrasound (TTUS) for needle approach to the pleural wall and adjacent lung and computed tomography (CT) -guidance for (seldom if ever used) endobronchial or (common) transthoracical approach. In several situations one technique is not enough for efficient diagnosis, therefore we investigated a new diagnostic technique of endobronchial guided biopsies by a Cone Beam Computertomography (CBCT) called DynaCT (SIEMENS AG Forchheim, Germany). In our study 33 incidental solitary pulmonary nodules (iSPNs) (28 malignant, 5 benign; mean diameter 25 +/-12mm, shortest distance to pleura 25+/-18mm) were eligible according to in- and exclusion criteria. Realtime and onsite navigation were performed according to our standard protocol.22 All iSPN were controlled with a second technique when necessary and clinical feasible in case of unspecific or unexpected histological result. In all cases common guidelines of treatment of different iSPNs were followed in a routine manner. Overall navigational yield (ny) was 91% and diagnostic yield (dy) 70%, dy for all accomplished malignant cases (n=28) was 82%. In the subgroup analysis of the invisible iSPN (n=12, 11 malignant, 1 benign; mean diameter 15+/-3mm) we found an overall dy of 75%. For the first time we describe a significant difference in specifity of biopsy results in regards to the position of the forceps in the 3-dimensional volume (3DV) of the iSPN in the whole sample group. Comparing the specifity of biopsies of a 3D-uncentered but inside the outer one third of an iSPN-3DV with the specifity of biopsies of centered forceps position (meaning the inner two third of an iSPN-3DV) reveals a significant (p=0,0375 McNemar) difference for the size group (>1cm) of 0,9 for centered biopsies vs. 0,3 for uncentered biopsies. Therefore only 3D-centered biopsies should be relied on especially in case of a benign result. The diagnostic yield of DynaCT navigation guided transbronchial biopsies (TBB) only with forceps is at least up to twofold higher than conventional TBB for iSPNs <2cm. The diagnostic yield of DynaCT navigation guided forceps TBB in invisible SPNs is at least in the range of other navigation studies which were performed partly with multiple navigation tools and multiple instruments. For future diagnostic and therapeutic approaches it is so far the only onsite and realtime extrathoracic navigation approach (except for computed tomography (CT)-fluoroscopy) in the bronchoscopy suite which keeps the working channel open. The system purchase represents an important investment for hospitals but it is a multidisciplinary and multinavigational tool with possible access via bronchial airways, transthoracical or vascular approach at the same time and on the same table without the need for an expensive disposable instrument use.
Koegelenberg, Coenraad Frederik N; Bolliger, Christoph Thomas; Theron, Johan; Walzl, Gerhard; Wright, Colleen Anne; Louw, Mercia; Diacon, Andreas Henri
2010-10-01
Tuberculous pleuritis remains the commonest cause of exudative effusions in areas with a high prevalence of tuberculosis and histological and/or microbiological confirmation on pleural tissue is the gold standard for its diagnosis. Uncertainty remains regarding the choice of closed pleural biopsy needles. This prospective study compared ultrasound-assisted Abrams and Tru-Cut needle biopsies with regard to their diagnostic yield for pleural tuberculosis. 89 patients (54 men) of mean ± SD age 38.7 ± 16.7 years with pleural effusions and a clinical suspicion of tuberculosis were enrolled in the study. Transthoracic ultrasound was performed on all patients, who were then randomly assigned to undergo ≥ 4 Abrams needle biopsies followed by ≥ 4 Tru-Cut needle biopsies or vice versa. Medical thoracoscopy was performed on cases with non-diagnostic closed biopsies. Histological and/or microbiological proof of tuberculosis on any pleural specimen was considered the gold standard for pleural tuberculosis. Pleural tuberculosis was diagnosed in 66 patients, alternative diagnoses were established in 20 patients and 3 remained undiagnosed. Pleural biopsy specimens obtained with Abrams needles contained pleural tissue in 81 patients (91.0%) and were diagnostic for tuberculosis in 54 patients (sensitivity 81.8%), whereas Tru-Cut needle biopsy specimens only contained pleural tissue in 70 patients (78.7%, p=0.015) and were diagnostic in 43 patients (sensitivity 65.2%, p=0.022). Ultrasound-assisted pleural biopsies performed with an Abrams needle are more likely to contain pleura and have a significantly higher diagnostic sensitivity for pleural tuberculosis.
Flat epithelial atypia of the breast: pathological-radiological correlation.
Solorzano, Silma; Mesurolle, Benoît; Omeroglu, Attila; El Khoury, Mona; Kao, Ellen; Aldis, Ann; Meterissian, Sarkis
2011-09-01
This study was undertaken to determine the prevalence of flat epithelial atypia at ultrasound-guided and stereotactically guided needle biopsies, to describe the mammographic and sonographic features of flat epithelial atypia, and to determine the significance of lesions diagnosed as flat epithelial atypia at imaging-guided needle biopsies. Retrospective review of a database of 1369 consecutive sonographically and stereotactically guided needle biopsies performed during a 12-month period yielded 33 lesions with flat epithelial atypia as the most severe pathologic entity (32 patients). Two radiologists retrospectively reviewed the imaging presentation, by combined consensus, according to the BI-RADS lexicon. Twenty-two of 33 flat epithelial atypia diagnoses (67%) were obtained under stereotactic guidance, and 11 (33%) were obtained under sonographic guidance. Six patients had synchronous breast cancer. Flat epithelial atypia lesions presented mammographically most often as microcalcifications (20/33 [61%]) distributed in a cluster (14/20 [70%]) with amorphous morphology (13/20 [65%]). Sonographically, flat epithelial atypia lesions appeared most often as masses (9/11 [82%]), with an irregular shape (6/9 [67%]), microlobulated margins (5/9 [56%]), and hypoechoic or complex echotexture (7/9 [78%]). Twenty-eight of 33 lesions (85%) were surgically excised, confirming the flat epithelial atypia diagnosis in 11 of the 28 lesions (39%), yielding carcinoma in four (14%) and atypical ductal hyperplasia in six (21%). Columnar cell changes without atypia were diagnosed in four lesions (14%), and lobular carcinoma in situ was diagnosed in three lesions (11%). Mammographic and sonographic presentation of flat epithelial atypia is not specific (clustered amorphous microcalcifications and irregular, hypoechoic or complex masses). Given the underestimation rate of malignancy, surgical excision should be considered when imaging-guided biopsy yields flat epithelial atypia.
[Evaluation of the learning curve of residents in localizing a phantom target with ultrasonography].
Dessieux, T; Estebe, J-P; Bloc, S; Mercadal, L; Ecoffey, C
2008-10-01
Few information are available regarding the learning curve in ultrasonography and even less for ultrasound-guided regional anesthesia. This study aimed to evaluate in a training program the learning curve on a phantom of 12 residents novice in ultrasonography. Twelve trainees inexperienced in ultrasonography were given introductory training consisting of didactic formation on the various components of the portable ultrasound machine (i.e. on/off button, gain, depth, resolution, and image storage). Then, students performed three trials, in two sets of increased difficulty, at executing these predefined tasks: adjustments of the machine, then localization of a small plastic piece introduced into roasting pork (3 cm below the surface). At the end of the evaluation, the residents were asked to insert a 22 G needle into an exact predetermined target (i.e. point of fascia intersection). The progression of the needle was continuously controlled by ultrasound visualization using injection of a small volume of water (needle perpendicular to the longitudinal plane of the ultrasound beam). Two groups of two different examiners evaluated for each three trials the skill of the residents (quality, time to perform the machine adjustments, to localize the plastic target, and to hydrolocalize, and volume used for hydrolocalization). After each trial, residents evaluated their performance using a difficulty scale (0: easy to 10: difficult). All residents performed the adjustments from the last trial of each set, with a learning curve observed in terms of duration. Localization of the plastic piece was achieved by all residents at the 6th trial, with a shorter duration of localization. Hydrolocalization was achieved after the 4th trial by all subjects. Difficulty scale was correlated to the number of trials. All these results were independent of the experience of residents in regional anesthesia. Four trials were necessary to adjust correctly the machine, to localize a target, and to complete hydrolocalization. Ultrasonography in regional anesthesia seems to be a fast-learning technique, using this kind of practical training.
Hari, Smriti; Kumari, Swati; Srivastava, Anurag; Thulkar, Sanjay; Mathur, Sandeep; Veedu, Prasad Thotton
2016-01-01
Background & objectives: Biopsy of palpable breast masses can be performed manually by palpation guidance or under imaging guidance. Based on retrospective studies, image guided biopsy is considered more accurate than palpation guided breast biopsy; however, these techniques have not been compared prospectively. We conducted this prospective study to verify the superiority and determine the size of beneficial effect of image guided biopsy over palpation guided biopsy. Methods: Over a period of 18 months, 36 patients each with palpable breast masses were randomized into palpation guided and image guided breast biopsy arms. Ultrasound was used for image guidance in 33 patients and mammographic (stereotactic) guidance in three patients. All biopsies were performed using 14 gauge automated core biopsy needles. Inconclusive, suspicious or imaging-histologic discordant biopsies were repeated. Results: Malignancy was found in 30 of 36 women in palpation guided biopsy arm and 27 of 36 women in image guided biopsy arm. Palpation guided biopsy had sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of 46.7, 100, 100, 27.3 per cent, respectively, for diagnosing breast cancer. Nineteen of 36 women (52.8%) required repeat biopsy because of inadequate samples (7 of 19), suspicious findings (2 of 19) or imaging-histologic discordance (10 of 19). On repeat biopsy, malignancy was found in all cases of imaging-histologic discordance. Image guided biopsy had 96.3 per cent sensitivity and 100 per cent specificity. There was no case of inadequate sample or imaging-histologic discordance with image guided biopsy. Interpretation & conclusions: Our results showed that in palpable breast masses, image guided biopsy was superior to palpation guided biopsy in terms of sensitivity, false negative rate and repeat biopsy rates. PMID:27488003
Multimodal US-gamma imaging using collaborative robotics for cancer staging biopsies.
Esposito, Marco; Busam, Benjamin; Hennersperger, Christoph; Rackerseder, Julia; Navab, Nassir; Frisch, Benjamin
2016-09-01
The staging of female breast cancer requires detailed information about the level of cancer spread through the lymphatic system. Common practice to obtain this information for patients with early-stage cancer is sentinel lymph node (SLN) biopsy, where LNs are radioactively identified for surgical removal and subsequent histological analysis. Punch needle biopsy is a less invasive approach but suffers from the lack of combined anatomical and nuclear information. We present and evaluate a system that introduces live collaborative robotic 2D gamma imaging in addition to live 2D ultrasound to identify SLNs in the surrounding anatomy. The system consists of a robotic arm equipped with both a gamma camera and a stereoscopic tracking system that monitors the position of an ultrasound probe operated by the physician. The arm cooperatively places the gamma camera parallel to the ultrasound imaging plane to provide live multimodal visualization and guidance. We validate the system by evaluating the target registration errors between fused nuclear and US image data in a phantom consisting of two spheres, one of which is filled with radioactivity. Medical experts perform punch biopsies on agar-gelatine phantoms with complex configurations of hot and cold lesions to provide a qualitative and quantitative evaluation of the system. The average point registration error for the overlay is [Formula: see text] mm. The time of the entire procedure was reduced by 36 %, with 80v of the biopsies being successful. The users' feedback was very positive, and the system was deemed to be very intuitive, with handling similar to classic US-guided needle biopsy. We present and evaluate the first medical collaborative robotic imaging system. Feedback from potential users for SLN punch needle biopsy is encouraging. Ongoing work investigates the clinical feasibility with more complex and realistic phantoms.
Ghaffar, Hasan; Parwani, Anil; Rosenthal, Dorothy L
2003-01-01
Hemangiopericytomas (HPCs) are rare spindle cell tumors, constituting 2.5% of soft tissue neoplasms. Few reports have addressed the fine needle aspiration (FNA) cytology of HPC. We describe the FNA biopsy (FNAB) findings in a 44-year-old patient with a previously resected meningeal hemangiopericytoma. The patient underwent ultrasound-guided FNAB of a 16.0-cm, radiographically heterogeneous density in the liver. The FNA smear showed crowded, ovoid to spindle-shaped cells with poorly defined, scant cytoplasm. The neoplastic cells were positive for CD34 and negative for CD31, factor VIII, glial fibrillary acid protein and cytokeratin AE1/AE3, supporting a diagnosis of HPC and compatible with metastasis from the patient's cerebral tumor. This case documents the role of FNA cytology in confirming HPC.
Zreik, Riyam; Soyalp, Krystal; Ruiz, Steve; Ward, Russell; Dobin, Sheila; Chen, Xiangbai; Liu, Lina; Rao, Arundhati
2015-04-01
Head and neck liposarcomas, while rare, tend to be subcutaneous and well-differentiated. Dedifferentiated liposarcomas of the head and neck are exceedingly rare in the literature. We present a case of a dedifferentiated liposarcoma arising in the soft tissue of the posterior neck of an 86-year-old man and diagnosed by fine-needle aspiration. Aspirate smears showed a dual population of atypical lipomatous and spindled cells. MDM2 (murine double minute 2) amplification was demonstrated on a Pap-stained smear using fluorescence in situ hybridization (FISH). To the best of our knowledge, this is the first report of MDM2 FISH amplification in a liposarcoma performed on an aspirate smear. © 2014 Wiley Periodicals, Inc.
Collado-Mesa, F; Net, J M; Arheart, K; Klevos, G A; Yepes, M M
2015-09-01
To assess whether the application of a topical vapocoolant spray immediately prior to initial intradermal anaesthetic injection during ultrasound-guided breast biopsy decreases pain at the site of the initial injection. In this institutional review board-approved, Health Insurance Portability and Accountability Act (HIPAA)-compliant study, 50 women aged 49.1 ± 1.6 years (mean ± standard error) were recruited and provided written informed consent. Participants served as their own controls and were blinded as to whether a topical vapocoolant spray or a placebo was used immediately prior to the initial local anaesthetic injection at two separate biopsy sites. With the exception of the application of vapocoolant or placebo, the entire ultrasound-guided procedure was performed according to a routine protocol. Participants recorded pain at initial injection site on a visual analogue scale. General linear mixed models for repeated measures analysis of variance and a 0.05 significance level were used. Application of topical vapocoolant spray was shown to significantly decrease pain at the site of initial intradermal anaesthetic injection as compared to placebo (p<0.001). Treatment effect was independent of age of the subject, race/ethnicity, operator, type of biopsy device, and histopathology result. No complications from vapocoolant spray use were reported. Application of a topical vapocoolant spray immediately prior to initial intradermal anaesthetic injection during ultrasound-guided breast biopsy significantly decreases pain at the site of the initial injection and could contribute to improve the patient's overall procedural experience. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Ultrasound-guided microinjection into the mouse forebrain in utero at E9.5.
Pierfelice, Tarran J; Gaiano, Nicholas
2010-11-13
In utero survival surgery in mice permits the molecular manipulation of gene expression during development. However, because the uterine wall is opaque during early embryogenesis, the ability to target specific parts of the embryo for microinjection is greatly limited. Fortunately, high-frequency ultrasound imaging permits the generation of images that can be used in real time to guide a microinjection needle into the embryonic region of interest. Here we describe the use of such imaging to guide the injection of retroviral vectors into the ventricular system of the mouse forebrain at embryonic day (E) 9.5. This method uses a laparotomy to permit access to the uterine horns, and a specially designed plate that permits host embryos to be bathed in saline while they are imaged and injected. Successful surgeries often result in most or all of the injected embryos surviving to any subsequent time point of interest (embryonically or postnatally). The principles described here can be used with slight modifications to perform injections into the amnionic fluid of E8.5 embryos (thereby permitting infection along the anterior posterior extent of the neural tube, which has not yet closed), or into the ventricular system of the brain at E10.5/11.5. Furthermore, at mid-neurogenic ages (~E13.5), ultrasound imaging can be used direct injection into specific brain regions for viral infection or cell transplantation. The use of ultrasound imaging to guide in utero injections in mice is a very powerful technique that permits the molecular and cellular manipulation of mouse embryos in ways that would otherwise be exceptionally difficult if not impossible.
Shital, Patil; Rujuta, Ayachit; Sanjay, Mundkar
2014-05-01
Lung cancer is the leading cause of cancer deaths around the world. Globally, lung cancer is the largest contributor to new cancer diagnosis and to death from cancer. Various conventional diagnostic techniques (CDTs) such as endobronchial forcep biopsy (FB), bronchial washing (BW) and bronchial brushing (BB), and transbronchial needle aspiration cytology (TBNA) are employed during fiber-optic bronchoscopy. This is a prospective study conducted between June 2012 and September 2013 at Bronchoscopy unit of MIMSR Medical College Latur, India, to find the role of TBNA in exophytic endobronchial lesions in confirming the diagnosis of lung cancer and to find additive yield over other techniques such as BB, BW and FB, and included 150 patients on the basis of clinical and radiological features of malignancy. In exophytic endobronchial lesions, predominant endoscopic findings were cauliflower, polypoidal-like or nodular or multinodular endobronchial growth. TBNA, FB, BB and BW were performed in all the cases during FOB. Histopathological and cytological examinations of specimens were performed at Pathology department. The statistical analysis was done using chi-square test. Total 150 patients, between age group 24-80 years, mean age was 57.93 years, male population constitutes 86.17 % of total. 76.14 % cases were smoker of them 61.87 % cases having history of >40 pack years. Commoner symptoms were cough (91.33 %), hemoptysis (54.00 %) and chest pain (46.66 %), and mass lesion (40.66 %), hilar opacity (31.33 %) and collapse segmental/lobar (29.33 %) were commoner radiological abnormalities. Yield of TBNA, CDT and TBNA plus CDT in exophytic lesions is 60.66, 79.33 and 84.66 %, respectively, in diagnosis of lung malignancies (P < 0.001). Sensitivity of forcep biopsy and TBNA in diagnosing lung malignancy was 88.18 and 71.65 %, respectively (P < 0.01). FOB-related hypoxemia documented in two cases and minor bleeding in six cases. Other complications such as significant bleeding, pneumothorax and death were not seen. Minor bleeding was seen with forcep biopsy mainly in 4.0 % cases. TBNA has decreased repeat procedure, decreases cost for diagnosis. IHC on TBNA specimens had increased histological-type confirmation. Transbronchial needle aspiration is a beneficial, safe and minimally invasive bronchoscopic technique with insignificant side effect in the diagnosis bronchogenic carcinoma. TBNA considered safe, especially when fleshy vascular endobronchial growth is present and risk of bleeding is high with forcep biopsy. Inadequate tissue sampling due to the presence of necrosis, blood clot over the lesion and formation of crush artifacts by FB makes TBNA valuable in these lesions. TBNA will definitely decrease need for repeat bronchoscopy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rivera-Sanfeliz, Gerant, E-mail: gerantrivera@ucsd.edu; Kinney, Thomas B.; Rose, Steven C.
2005-06-15
Purpose: To describe our experience with ultrasound (US)-guided percutaneous liver biopsies using the INRAD 18G Express core needle biopsy system.Methods: One hundred and fifty-four consecutive percutaneous core liver biopsy procedures were performed in 153 men in a single institution over 37 months. The medical charts, pathology reports, and radiology files were retrospectively reviewed. The number of needle passes, type of guidance, change in hematocrit level, and adequacy of specimens for histologic analysis were evaluated.Results: All biopsies were performed for histologic staging of chronic liver diseases. The majority of patients had hepatitis C (134/153, 90.2%). All patients were discharged to homemore » after 4 hr of postprocedural observation. In 145 of 154 (94%) biopsies, a single needle pass was sufficient for diagnosis. US guidance was utilized in all but one of the procedures (153/154, 99.4%). The mean hematocrit decrease was 1.2% (44.1-42.9%). Pain requiring narcotic analgesia, the most frequent complication, occurred in 28 of 154 procedures (18.2%). No major complications occurred. The specimens were diagnostic in 152 of 154 procedures (98.7%).Conclusions: Single-pass percutaneous US-guided liver biopsy with the INRAD 18G Express core needle biopsy system is safe and provides definitive pathologic diagnosis of chronic liver disease. It can be performed on an outpatient basis. Routine post-biopsy monitoring of hematocrit level in stable, asymptomatic patients is probably not warranted.« less
NASA Astrophysics Data System (ADS)
Rodgers, Jessica R.; Surry, Kathleen; D'Souza, David; Leung, Eric; Fenster, Aaron
2017-03-01
Treatment for gynaecological cancers often includes brachytherapy; in particular, in high-dose-rate (HDR) interstitial brachytherapy, hollow needles are inserted into the tumour and surrounding area through a template in order to deliver the radiation dose. Currently, there is no standard modality for visualizing needles intra-operatively, despite the need for precise needle placement in order to deliver the optimal dose and avoid nearby organs, including the bladder and rectum. While three-dimensional (3D) transrectal ultrasound (TRUS) imaging has been proposed for 3D intra-operative needle guidance, anterior needles tend to be obscured by shadowing created by the template's vaginal cylinder. We have developed a 360-degree 3D transvaginal ultrasound (TVUS) system that uses a conventional two-dimensional side-fire TRUS probe rotated inside a hollow vaginal cylinder made from a sonolucent plastic (TPX). The system was validated using grid and sphere phantoms in order to test the geometric accuracy of the distance and volumetric measurements in the reconstructed image. To test the potential for visualizing needles, an agar phantom mimicking the geometry of the female pelvis was used. Needles were inserted into the phantom and then imaged using the 3D TVUS system. The needle trajectories and tip positions in the 3D TVUS scan were compared to their expected values and the needle tracks visualized in magnetic resonance images. Based on this initial study, 360-degree 3D TVUS imaging through a sonolucent vaginal cylinder is a feasible technique for intra-operatively visualizing needles during HDR interstitial gynaecological brachytherapy.
Yan, Lei; Ikemura, Kenji; Park, Ji-Weon
2018-02-01
Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) and endoscopic ultrasound-guided core-needle biopsy (EUS-CNB) are widely used for diagnosis of pancreatic tumors. The aim of our study was to compare the diagnostic performance of ROSE EUS-FNA and EUS-CNB for diagnosis of pancreatic malignancy during the same EUS. Patients who underwent both FNA and CNB during the same EUS for pancreatic solid lesion were reviewed retrospectively. Sample adequacy, diagnostic yield (defined as percentage of definitive diagnosis), sensitivity and specificity for malignancy were compared between FNA and CNB. A total of 48 patients with solid pancreatic lesions were evaluated. The proportions of adequate samples were 48/48 (100%) for FNA and 45/48 (93.7%) for core biopsy (P = .24). The diagnostic yield was 42/48 (87.5%) and 33/48 (68.7%) for FNA and CNB respectively (P = .046). The incremental increase in diagnostic yield by combining both methods was 2/48 (4%). The diagnostic yield for malignancy was 30/32 (93.7%) for FNA and 23/32 (71.8%) for CNB (P = .043). The sensitivity for the diagnosis of malignancy for FNA and CNB were 90.6% and 69%, respectively (P = .045). The specificity was 100% for both methods. The sensitivity for diagnosing malignancy increased to 93.8% when the two methods were combined. The difference in diagnostic yield was not associated with lesion size or location. EUS-guided FNA is a superior method of assessing solid pancreatic lesion and pancreatic malignancy with better diagnostic yield and higher sensitivity than EUS-CNB. © 2017 Wiley Periodicals, Inc.
Shahait, Mohammed; Degheili, Jad; El-Merhi, Fadi; Tamim, Hani; Nasr, Rami
2016-01-01
ABSTRACT Background Urosepsis is a rare but life-threatening complication following transrectal ultrasound (TRUS) guided needle prostate biopsy. Despite the technological and pharmacological improvements, the problem of bacterial urosepsis after prostate biopsy remains. A strategy for preventing urosepsis following TRUS prostate biopsy in areas with high prevalence of resistant strains or patients presenting risk factors is lacking. Objectives The aim of this study was to assess the prevalence of urosepsis, as well its predictors, following TRUS guided needle biopsy of the prostate in a tertiary care medical center in Lebanon. Materials and Methods We carried out a retrospective study on all patients who underwent TRUS prostate biopsy at the American University of Beirut Medical Center between January 1, 2011 and June 31, 2013. Patients’ hospital charts were reviewed. Data collected included demographic information, pre-procedure disease specific information, as well as post-procedure information. Predictors of urosepsis following TRUS were assessed. Results In total, 265 patients were included in this study, where the prevalence of urosepsis following TRUS prostate biopsy was found to be 9.4%. The significant independent predictors of urosepsis were found to be: age with an OR=0.93 (95% CI: 0.88–1.00, p-value=0.03), and hypertension comorbidity with an OR=3.25 (95% CI: 1.19–8.85, p-value=0.02). Conclusion We found a high prevalence of urosepsis among patients who have undergone TRUS prostate biopsy, and identified two significant risk factors. The results of this study highlight the importance of implementing strategies for prevention of urosepsis following TRUS prostate biopsy. PMID:27136468
Utilization of Ancillary Studies in the Cytologic Diagnosis of Respiratory Lesions
Layfield, Lester J.; Roy-Chowdhuri, Sinchita; Baloch, Zubair; Ehya, Hormoz; Geisinger, Kim; Hsiao, Susan J.; Lin, Oscar; Lindeman, Neal I.; Roh, Michael; Schmitt, Fernando; Sidiropoulos, Nikoletta; VanderLaan, Paul A.
2017-01-01
The Papanicolaou Society of Cytopathology has developed a set of guidelines for respiratory cytology including indications for sputum examination, bronchial washings and brushings, CT-guided FNA and endobronchial ultrasound guided fine needle aspiration (EBUS-FNA), as well as recommendations for classification and criteria, ancillary testing and post-cytologic diagnosis management and follow-up. All recommendation documents are based on the expertise of committee members, an extensive literature review, and feedback from presentations at national and international conferences. The guideline documents selectively present the results of these discussions. The present document summarizes recommendations for ancillary testing of cytologic samples. Ancillary testing including microbiologic, immunocytochemical, flow cytometric, and molecular testing, including next-generation sequencing are discussed. PMID:27561242
Needle Steering in Biological Tissue using Ultrasound-based Online Curvature Estimation
Moreira, Pedro; Patil, Sachin; Alterovitz, Ron; Misra, Sarthak
2014-01-01
Percutaneous needle insertions are commonly performed for diagnostic and therapeutic purposes. Accurate placement of the needle tip is important to the success of many needle procedures. The current needle steering systems depend on needle-tissue-specific data, such as maximum curvature, that is unavailable prior to an interventional procedure. In this paper, we present a novel three-dimensional adaptive steering method for flexible bevel-tipped needles that is capable of performing accurate tip placement without previous knowledge about needle curvature. The method steers the needle by integrating duty-cycled needle steering, online curvature estimation, ultrasound-based needle tracking, and sampling-based motion planning. The needle curvature estimation is performed online and used to adapt the path and duty cycling. We evaluated the method using experiments in a homogenous gelatin phantom, a two-layer gelatin phantom, and a biological tissue phantom composed of a gelatin layer and in vitro chicken tissue. In all experiments, virtual obstacles and targets move in order to represent the disturbances that might occur due to tissue deformation and physiological processes. The average targeting error using our new adaptive method is 40% lower than using the conventional non-adaptive duty-cycled needle steering method. PMID:26229729
Liu, Yang; Glass, Nancy L; Power, Robert W
2010-04-01
There is a pronounced learning curve for the technique of ultrasound-guided regional anesthesia. Practicing with a simulator model has been shown to speed the acquisition of these skills for various ultrasound-guided procedures. However, commercial models for ultrasound-guided regional anesthesia may be too costly or not readily available. Models using turkey breasts or tofu blocks have the disadvantage of containing perishable food products that can be a source for infection. We describe an alternative inexpensive model that is made from nonperishable components readily available in the operating room. The materials required include 1 clean used 500-mL bag of IV fluids, a bottle of Premisorb (TYCO Healthcare Group, Mansfield, MA), and a piece of foam material approximately 0.3 cm in diameter and 5 cm in length trimmed from operating room foam pads. After filling the IV bag with tap water and inserting the foam into the IV bag from the outlet port of the IV bag, one-third of a bottle of Premisorb (approximately 15 g) is poured into the IV bag. The outlet port of the bag is then sealed by taping the rubber stopper that originally came with the bag. Premisorb, a solidifying agent frequently used to absorb irrigating fluids or blood in operating room suction canisters, produces a gel-like material in the IV bag. The foam inserted into the bag creates a relatively hyperechoic target. This gel-like substance in the bag will seal the holes created after multiple practice needle insertions, resulting in minimal leakage. The semitransparent nature of the gel allows the trainee to visualize the target directly and on the ultrasound screen. The model we describe is inexpensive and easy to make from materials readily available in the operating room with the advantages of being nonperishable, easy to carry, and reusable.
A new needle on the block: EchoTip ProCore endobronchial ultrasound needle
Dincer, H Erhan; Andrade, Rafael; Zamora, Felix; Podgaetz, Eitan
2016-01-01
Endobronchial ultrasound has become the first choice standard of care procedure to diagnose benign or malignant lesions involving mediastinum and lung parenchyma adjacent to the airways owing to its characteristics of being real-time and minimally invasive. Although the incidence of lung cancer has been decreasing, it is and will be the leading cause of cancer-related mortality in the next few decades. When compared to other cancers, lung cancer kills more females than breast and colon cancers combined and more males than colon and prostate cancers combined. The type of lung cancer has changed in recent decades and adenocarcinoma has become the most frequent cell type. Prognosis of lung cancer depends upon the cell type and the staging at the time of diagnosis. The cell type and molecular characteristics of adenocarcinoma may allow individualized targeted treatment. Other malignant conditions in the mediastinum and lung (eg, metastatic lung cancers and lymphoma) can be biopsied using endobronchial ultrasound needles. Endobronchial ultrasound needle biopsies provides mostly cytology specimens due to its small sizes of needles (22 gauge or larger) which may not give enough tissue to make a definitive diagnosis in malignant (eg, lymphoma) or benign conditions (eg, sarcoidosis). EchoTip ProCore endobronchial needle released in early 2014 provides histologic biopsy material. Larger tissue biopsies may potentially provide a higher diagnostic yield and it eliminates mediastinoscopy or other surgical interventions. Here we aim to review bronchoscopic approach in the diagnosis of mediastinal lesions with emphasis of EchoTip ProCore needles. PMID:27099535
Zerth, Herb; Harwood, Robert; Tommaso, Laura; Girzadas, Daniel V
2012-12-01
Pericardiocentesis is a low-frequency, high-risk procedure integral to the practice of emergency medicine. Ultrasound-guided pericardiocentesis is the preferred technique for providing this critical intervention. Traditionally, emergency physicians learned pericardiocentesis in real time, at the bedside, on critically ill patients. Medical education is moving toward simulation for training and assessment of procedures such as pericardiocentesis because it allows learners to practice time-sensitive skills without risk to patient or learner. The retail market for models for pericardiocentesis practice is limited and expensive. We have developed an ultrasound-guided pericardiocentesis task trainer that allows the physician to insert a needle under ultrasound guidance, pierce the "pericardial sac" and aspirate "blood." Our model can be simply constructed in a home kitchen, and the overall preparation time is 1 h. Our model costs $20.00 (US, 2008). Materials needed for the construction include 16 ounces of plain gelatin, one large balloon, one golf ball, food coloring, non-stick cooking spray, one wooden cooking skewer, surgical iodine solution, and a 4-quart sized plastic food storage container. Refrigeration and a heat source for cooking are also required. Once prepared, the model is usable for 2 weeks at room temperature and may be preserved an additional week if refrigerated. When the model shows signs of wear, it can be easily remade, by simply recycling the existing materials. The self-made model was well liked by training staff due to accessibility of a simulation model, and by learners of the technique as they felt more at ease performing pericardiocentesis on a live patient. Copyright © 2012 Elsevier Inc. All rights reserved.
MO-FG-210-02: Implementation of Image-Guided Prostate HDR Brachytherapy Using MR-Ultrasound Fusion
DOE Office of Scientific and Technical Information (OSTI.GOV)
Libby, B.
Ultrasound (US) is one of the most widely used imaging modalities in medical practice. Since US imaging offers real-time imaging capability, it has becomes an excellent option to provide image guidance for brachytherapy (IGBT). (1) The physics and the fundamental principles of US imaging are presented, and the typical steps required to commission an US system for IGBT is provided for illustration. (2) Application of US for prostate HDR brachytherapy, including partial prostate treatments using MR-ultrasound co-registration to enable a focused treatment on the disease within the prostate is also presented. Prostate HDR with US image guidance planning can benefitmore » from real time visualization of the needles, and fusion of the ultrasound images with T2 weighted MR allows the focusing of the treatment to the specific areas of disease within the prostate, so that the entire gland need not be treated. Finally, (3) ultrasound guidance for an eye plaque program is presented. US can be a key component of placement and QA for episcleral plaque brachytherapy for ocular cancer, and the UCLA eye plaque program with US for image guidance is presented to demonstrate the utility of US verification of plaque placement in improving the methods and QA in episcleral plaque brachytherapy. Learning Objectives: To understand the physics of an US system and the necessary aspects of commissioning US for image guided brachytherapy (IGBT). To understand real time planning of prostate HDR using ultrasound, and its application in partial prostate treatments using MR-ultrasound fusion to focus treatment on disease within the prostate. To understand the methods and QA in applying US for localizing the target and the implant during a episcleral plaque brachytherapy procedures.« less
Paeng, Dong-Guk; Chang, Jin Ho; Chen, Ruimin; Humayun, Mark S.; Shung, K. Kirk
2009-01-01
High frequency ultrasound over 40 MHz has been used to image the anterior segment of the eye, but it is not suitable for the posterior segment due to the frequency-dependent attenuation of ultrasound and thus the limitation of penetration depth. This paper proposes a novel scan method to image the posterior segment of the eye with an angled high frequency (beyond 40 MHz) ultrasound needle transducer. In this method, the needle transducer is inserted into the eye through a small incision hole (∼1 mm in diameter) and rotated around the axial direction to form a cone-shaped imaging plane, allowing the spatial information of retinal vessels and diagnosis of their occlusion to be displayed. The feasibility of this novel technique was tested with images of a wire phantom, a polyimide tube, and an excised pig eye obtained by manually rotating a 40-MHz PMN-PT needle transducer with a beveled tip of 45°. From the results, we believe that rotational scan imaging will help expand the minimally invasive applications of high frequency ultrasound to other areas due to the capability of increased closeness of an angled needle transducer to structures of interest buried in other tissues. PMID:19411226
Paeng, Dong-Guk; Chang, Jin Ho; Chen, Ruimin; Humayun, Mark S; Shung, K Kirk
2009-03-01
High frequency ultrasound over 40 MHz has been used to image the anterior segment of the eye, but it is not suitable for the posterior segment due to the frequency dependent attenuation of ultrasound and thus the limitation of penetration depth. This paper proposes a novel scan method to image the posterior segment of the eye with an angled high frequency (beyond 40 MHz) ultrasound needle transducer. In this method, the needle transducer is inserted into the eye through a small incision hole (approximately 1 mm in diameter) and rotated around the axial direction to form a cone-shaped imaging plane, allowing the spatial information of retinal vessels and diagnosis of their occlusion to be displayed. The feasibility of this novel technique was tested with images of a wire phantom, a polyimide tube, and an excised pig eye obtained by manually rotating a 40-MHz PMN-PT needle transducer with a beveled tip of 45 degrees . From the results, we believe that rotational scan imaging will help expand the minimally invasive applications of high frequency ultrasound to other areas due to the capability of increased closeness of an angled needle transducer to structures of interest buried in other tissues.
Interventional radiology virtual simulator for liver biopsy.
Villard, P F; Vidal, F P; ap Cenydd, L; Holbrey, R; Pisharody, S; Johnson, S; Bulpitt, A; John, N W; Bello, F; Gould, D
2014-03-01
Training in Interventional Radiology currently uses the apprenticeship model, where clinical and technical skills of invasive procedures are learnt during practice in patients. This apprenticeship training method is increasingly limited by regulatory restrictions on working hours, concerns over patient risk through trainees' inexperience and the variable exposure to case mix and emergencies during training. To address this, we have developed a computer-based simulation of visceral needle puncture procedures. A real-time framework has been built that includes: segmentation, physically based modelling, haptics rendering, pseudo-ultrasound generation and the concept of a physical mannequin. It is the result of a close collaboration between different universities, involving computer scientists, clinicians, clinical engineers and occupational psychologists. The technical implementation of the framework is a robust and real-time simulation environment combining a physical platform and an immersive computerized virtual environment. The face, content and construct validation have been previously assessed, showing the reliability and effectiveness of this framework, as well as its potential for teaching visceral needle puncture. A simulator for ultrasound-guided liver biopsy has been developed. It includes functionalities and metrics extracted from cognitive task analysis. This framework can be useful during training, particularly given the known difficulties in gaining significant practice of core skills in patients.
Augmented Reality-Guided Lumbar Facet Joint Injections.
Agten, Christoph A; Dennler, Cyrill; Rosskopf, Andrea B; Jaberg, Laurenz; Pfirrmann, Christian W A; Farshad, Mazda
2018-05-08
The aim of this study was to assess feasibility and accuracy of augmented reality-guided lumbar facet joint injections. A spine phantom completely embedded in hardened opaque agar with 3 ring markers was built. A 3-dimensional model of the phantom was uploaded to an augmented reality headset (Microsoft HoloLens). Two radiologists independently performed 20 augmented reality-guided and 20 computed tomography (CT)-guided facet joint injections each: for each augmented reality-guided injection, the hologram was manually aligned with the phantom container using the ring markers. The radiologists targeted the virtual facet joint and tried to place the needle tip in the holographic joint space. Computed tomography was performed after each needle placement to document final needle tip position. Time needed from grabbing the needle to final needle placement was measured for each simulated injection. An independent radiologist rated images of all needle placements in a randomized order blinded to modality (augmented reality vs CT) and performer as perfect, acceptable, incorrect, or unsafe. Accuracy and time to place needles were compared between augmented reality-guided and CT-guided facet joint injections. In total, 39/40 (97.5%) of augmented reality-guided needle placements were either perfect or acceptable compared with 40/40 (100%) CT-guided needle placements (P = 0.5). One augmented reality-guided injection missed the facet joint space by 2 mm. No unsafe needle placements occurred. Time to final needle placement was substantially faster with augmented reality guidance (mean 14 ± 6 seconds vs 39 ± 15 seconds, P < 0.001 for both readers). Augmented reality-guided facet joint injections are feasible and accurate without potentially harmful needle placement in an experimental setting.
Iftimia, Nicusor; Park, Jesung; Maguluri, Gopi; Krishnamurthy, Savitri; McWatters, Amanda; Sabir, Sharjeel H
2018-02-01
We report the development and the pre-clinical testing of a new technology based on optical coherence tomography (OCT) for investigating tissue composition at the tip of the core biopsy needle. While ultrasound, computed tomography, and magnetic resonance imaging are routinely used to guide needle placement within a tumor, they still do not provide the resolution needed to investigate tissue cellularity (ratio between viable tumor and benign stroma) at the needle tip prior to taking a biopsy core. High resolution OCT imaging, however, can be used to investigate tissue morphology at the micron scale, and thus to determine if the biopsy core would likely have the expected composition. Therefore, we implemented this capability within a custom-made biopsy gun and evaluated its capability for a correct estimation of tumor tissue cellularity. A pilot study on a rabbit model of soft tissue cancer has shown the capability of this technique to provide correct evaluation of tumor tissue cellularity in over 85% of the cases. These initial results indicate the potential benefit of the OCT-based approach for improving the success of the core biopsy procedures.
Boonsarngsuk, Viboon; Kanoksil, Wasana; Laungdamerongchai, Sarangrat
2015-04-01
There are many sampling techniques dedicated to radial endobronchial ultrasound (R-EBUS) guided flexible bronchoscopy (FB). However, data regarding the diagnostic performances among bronchoscopic sampling techniques is limited. This study was conducted to compare the diagnostic yields among bronchoscopic sampling techniques in the diagnosis of peripheral pulmonary lesions (PPLs). A prospective study was conducted on 112 patients who were diagnosed with PPLs and underwent R-EBUS-guided FB between Oct 2012 and Sep 2014. Sampling techniques-including transbronchial biopsy (TBB), brushing cell block, brushing smear, rinsed fluid of brushing, and bronchoalveolar lavage (BAL)-were evaluated for the diagnosis. The mean diameter of the PPLs was 23.5±9.5 mm. The final diagnoses included 76 malignancies and 36 benign lesions. The overall diagnostic yield of R-EBUS-guided bronchoscopy was 80.4%; TBB gave the highest yield among the 112 specimens: 70.5%, 34.8%, 62.5%, 50.0% and 42.0% for TBB, brushing cell block, brushing smear, rinsed brushing fluid, and BAL fluid (BALF), respectively (P<0.001). TBB provided high diagnostic yield irrespective of the size and etiology of the PPLs. The combination of TBB and brushing smear achieved the maximum diagnostic yield. Of 31 infectious PPLs, BALF culture gave additional microbiological information in 20 cases. TBB provided the highest diagnostic yield; however, to achieve the highest diagnostic performance, TBB, brushing smear and BAL techniques should be performed together.
Motorized fusion guided prostate biopsy: phantom study
NASA Astrophysics Data System (ADS)
Seifabadi, Reza; Xu, Sheng; Aalamifar, Fereshteh; Pinto, Peter; Wood, Bradford J.
2017-03-01
Purpose: Fusion of Magnetic Resonance Imaging (MRI) with intraoperative real-time Ultrasound (US) during prostate biopsy has significantly improved the sensitivity of transrectal ultrasound (TRUS) guided cancer detection. Currently, sweeping of the TRUS probe to build a 3D volume as part of the fusion process and the TRUS probe manipulation for needle guidance are both done manually. A motorized, joystick controlled, probe holder was custom fabricated that can potentially reduce inter-operator variability, provide standardization of needle placement, improve repeatability and uniformity of needle placement, which may have impacts upon the learning curve after clinical deployment of this emerging approach. Method: a 2DOF motorized probe holder was designed to provide translation and rotation of a triplane TRUS end firing probe for prostate biopsy. The probe holder was joystick controlled and can assist manipulation of the probe during needle insertion as well as in acquiring a smoother US 2D to 3D sweep in which the 3D US volume for fusion is built. A commercial MRI-US fusion platform was used. Three targets were specified on MR image of a commercial prostate phantom. After performing the registration, two operators performed targeting, once manually and once with the assistance of the motorized probe holder. They repeated these tasks 5 times resulting in a total of 30 targeting events. Time of completion and mechanical error i.e. distance of the target from the needle trajectory in the software user interface were measured. Repeatability in reaching a given target in a systematic and consistent way was measured using a scatter plot showing all targets in the US coordinate system. Pearson product-moment correlation coefficient (PPMCC) was used to demonstrate the probe steadiness during targeting. Results: the completion time was 25+/-17 sec, 25+/-24 sec, and 27+/-15 sec for free hand and 24+/-10 sec, 22.5+/-10 sec, and 37+/-10 sec for motorized insertion, for target 1, 2, and 3, respectively. The mechanical error was 0.75+/-0.4 mm, 0.45+/-0.4 mm, and 0.55+/-0.4 mm, for free hand approach while it was 1.0+/-0.57 mm, 0.45+/-0.4 mm, and 0.35+/-0.25 mm, for motorized approach, for target 1, 2, and 3, respectively. PPMCC remained almost at 1.0 for the motorized approach while having a variation between 0.9 and 1.0 for the free hand approach. Conclusions: motorized fusion guided prostate biopsy in a phantom study was feasible and non-inferior or comparable to the free hand manual approach in terms of accuracy and speed of targeting, while being superior in terms of repeatability and steadiness.
Positional calibration of an ultrasound image-guided robotic breast biopsy system.
Nelson, Thomas R; Tran, Amy; Fakourfar, Hourieh; Nebeker, Jakob
2012-03-01
Precision biopsy of small lesions is essential in providing high-quality patient diagnosis and management. Localization depends on high-quality imaging. We have developed a dedicated, fully automatic volume breast ultrasound (US) imaging system for early breast cancer detection. This work focuses on development of an image-guided robotic biopsy system that is integrated with the volume breast US system for performing minimally invasive breast biopsies. The objective of this work was to assess the positional accuracy of the robotic system for breast biopsy. We have adapted a compact robotic arm for performing breast biopsy. The arm incorporates a force torque sensor and is modified to accommodate breast biopsy sampling needles mounted on the robot end effector. Volume breast US images are used as input to a targeting algorithm that provides the physician with control of biopsy device guidance and trajectory optimization. In this work, the positional accuracy was evaluated using (1) a light-emitting diode (LED) mounted on the end effector and (2) a LED mounted on the end of a biopsy needle, each of which was imaged for each robot controller position as part of mapping the positional accuracy throughout a volume that would contain the breast. We measured the error in each location and the cumulative error. Robotic device performance over the volume provided mean accuracy ± SD of 0.76 ± 0.13 mm (end effector) and 0.55 ± 0.13 mm (needle sample location), sufficient for a targeting accuracy within ±1 mm, which is suitable for clinical use. Depth positioning error also was small: 0.38 ± 0.03 mm. Reproducibility was excellent with less than 0.5% variation. Overall accuracy and reproducibility of the compact robotic device were excellent, well within clinical biopsy performance requirements. Volume breast US data provide high-quality input to a biopsy sampling algorithm under physician control. Robotic devices may provide more precise device placement, assisting physicians with biopsy procedures.
Deep Needle Procedures: Improving Safety With Ultrasound Visualization
Peabody, Christopher R.; Mandavia, Diku
2017-01-01
Abstract Promoting patient safety and increasing health care quality have dominated the health care landscape during the last 15 years. Health care regulators and payers are now tying patient safety outcomes and best practices to hospital reimbursement. Many health care leaders are searching for new technologies that not only make health care for patients safer but also reduce overall health care costs. New advances in ultrasonography have made this technology available to health care providers at the patient’s bedside. Point-of-care ultrasound assistance now aids providers with real-time diagnosis and with visualization for procedural guidance. This is especially true for common deep needle procedures such as central venous catheter insertion, thoracentesis, and paracentesis. There is now mounting evidence that clinician-performed point-of-care ultrasound improves patient safety, enhances health care quality, and reduces health care cost for deep needle procedures. Furthermore, the miniaturization, ease of use, and the evolving affordability of ultrasound have now made this technology widely available. The adoption of point-of-care ultrasonography has reached a tipping point and should be seriously considered the safety standard for all hospital-based deep needle procedures. PMID:24786918
Enabling image fusion for a CT guided needle placement robot
NASA Astrophysics Data System (ADS)
Seifabadi, Reza; Xu, Sheng; Aalamifar, Fereshteh; Velusamy, Gnanasekar; Puhazhendi, Kaliyappan; Wood, Bradford J.
2017-03-01
Purpose: This study presents development and integration of hardware and software that enables ultrasound (US) and computer tomography (CT) fusion for a FDA-approved CT-guided needle placement robot. Having real-time US image registered to a priori-taken intraoperative CT image provides more anatomic information during needle insertion, in order to target hard-to-see lesions or avoid critical structures invisible to CT, track target motion, and to better monitor ablation treatment zone in relation to the tumor location. Method: A passive encoded mechanical arm is developed for the robot in order to hold and track an abdominal US transducer. This 4 degrees of freedom (DOF) arm is designed to attach to the robot end-effector. The arm is locked by default and is released by a press of button. The arm is designed such that the needle is always in plane with US image. The articulated arm is calibrated to improve its accuracy. Custom designed software (OncoNav, NIH) was developed to fuse real-time US image to a priori-taken CT. Results: The accuracy of the end effector before and after passive arm calibration was 7.07mm +/- 4.14mm and 1.74mm +/-1.60mm, respectively. The accuracy of the US image to the arm calibration was 5mm. The feasibility of US-CT fusion using the proposed hardware and software was demonstrated in an abdominal commercial phantom. Conclusions: Calibration significantly improved the accuracy of the arm in US image tracking. Fusion of US to CT using the proposed hardware and software was feasible.
Xu, Mei-Mei; Jia, Hong-Yu; Yan, Li-Li; Li, Shan-Shan; Zheng, Yue
2017-01-01
Abstract Background: This meta-analysis aimed to provide a pooled analysis of prospective controlled trials comparing the diagnostic accuracy of 22-G and 25-G needles on endoscopic ultrasonography (EUS-FNA) of the solid pancreatic mass. Methods: We established a rigorous study protocol according to Cochrane Collaboration recommendations. We systematically searched the PubMed and Embase databases to identify articles to include in the meta-analysis. Sensitivity, specificity, and corresponding 95% confidence intervals were calculated for 22-G and 25-G needles of individual studies from the contingency tables. Results: Eleven prospective controlled trials included a total of 837 patients (412 with 22-G vs 425 with 25-G). Our outcomes revealed that 25-G needles (92% [95% CI, 89%–95%]) have higher sensitivity than 22-G needles (88% [95% CI, 84%–91%]) on solid pancreatic mass EUS-FNA (P = 0.046). However, there were no significant differences between the 2 groups in overall diagnostic specificity (P = 0.842). The pooled positive and negative likelihood ratio of the 22-G needle were 12.61 (95% CI, 5.65–28.14) and 0.16 (95% CI, 0.12–0.21), respectively. The pooled positive likelihood ratio was 12.61 (95% CI, 5.65–28.14), and the negative likelihood ratio was 0.16 (95% CI, 0.12–0.21) for the 22-G needle. The pooled positive likelihood ratio was 8.44 (95% CI, 3.87–18.42), and the negative likelihood ratio was 0.13 (95% CI, 0.09–0.18) for the 25-G needle. The area under the summary receiver operating characteristic curve was 0.97 for the 22-G needle and 0.96 for the 25-G needle. Conclusion: Compared to the study of 22-G EUS-FNA needles, our study showed that 25-G needles have superior sensitivity in the evaluation of solid pancreatic lesions by EUS–FNA. PMID:28151856
Can Breast Cancer Biopsy Influence Sentinel Lymph Node Status?
Giuliani, Michela; Patrolecco, Federica; Rella, Rossella; Di Giovanni, Silvia Eleonora; Infante, Amato; Rinaldi, Pierluigi; Romani, Maurizio; Mulè, Antonino; Arciuolo, Damiano; Belli, Paolo; Bonomo, Lorenzo
2016-12-01
We evaluated whether the needle size could influence metastasis occurrence in the axillary sentinel lymph node (SLN) in ultrasound-guided core needle biopsy (US-CNB) of breast cancer (BC). The data from all patients with breast lesions who had undergone US-CNB at our institution from January 2011 to January 2015 were retrospectively reviewed. A total of 377 BC cases were included using the following criteria: (1) percutaneous biopsy-proven invasive BC; and (2) SLN dissection with histopathologic examination. The patients were divided into 2 groups according to the needle size used: 14 gauge versus 16 or 18 gauge. SLN metastasis classification followed the 7th American Joint Committee on Cancer (2010) TNM pathologic staging factors: macrometastases, micrometastases, isolated tumor cells, or negative. Only macrometastases and micrometastases were considered positive, and the positive and negative rates were calculated for the overall population and for both needle size groups. Of the 377 BC cases, 268 US-CNB procedures were performed using a 14-gauge needle and 109 with a 16- or 18-gauge needle, respectively. The negative rate was significantly related statistically with the needle size, with a greater prevalence in the 14-gauge group on both extemporaneous analysis (P = .019) and definitive analysis (P = .002). The macrometastasis rate was 17% (63 of 377) for the 14-gauge and 3% (12 of 377) for the 16- and 18-gauge needles, respectively. Our preliminary results have suggested that use of a large needle size in CNB does not influence SLN status; thus, preoperative breast biopsy can be considered a safe procedure in the diagnosis of malignant breast lesions. Copyright © 2016 Elsevier Inc. All rights reserved.
American Thyroid Association statement on preoperative imaging for thyroid cancer surgery.
Yeh, Michael W; Bauer, Andrew J; Bernet, Victor A; Ferris, Robert L; Loevner, Laurie A; Mandel, Susan J; Orloff, Lisa A; Randolph, Gregory W; Steward, David L
2015-01-01
The success of surgery for thyroid cancer hinges on thorough and accurate preoperative imaging, which enables complete clearance of the primary tumor and affected lymph node compartments. This working group was charged by the Surgical Affairs Committee of the American Thyroid Association to examine the available literature and to review the most appropriate imaging studies for the planning of initial and revision surgery for thyroid cancer. Ultrasound remains the most important imaging modality in the evaluation of thyroid cancer, and should be used routinely to assess both the primary tumor and all associated cervical lymph node basins preoperatively. Positive lymph nodes may be distinguished from normal nodes based upon size, shape, echogenicity, hypervascularity, loss of hilar architecture, and the presence of calcifications. Ultrasound-guided fine-needle aspiration of suspicious lymph nodes may be useful in guiding the extent of surgery. Cross-sectional imaging (computed tomography with contrast or magnetic resonance imaging) may be considered in select circumstances to better characterize tumor invasion and bulky, inferiorly located, or posteriorly located lymph nodes, or when ultrasound expertise is not available. The above recommendations are applicable to both initial and revision surgery. Functional imaging with positron emission tomography (PET) or PET-CT may be helpful in cases of recurrent cancer with positive tumor markers and negative anatomic imaging.
American Thyroid Association Statement on Preoperative Imaging for Thyroid Cancer Surgery
Bauer, Andrew J.; Bernet, Victor A.; Ferris, Robert L.; Loevner, Laurie A.; Mandel, Susan J.; Orloff, Lisa A.; Randolph, Gregory W.; Steward, David L.
2015-01-01
Background: The success of surgery for thyroid cancer hinges on thorough and accurate preoperative imaging, which enables complete clearance of the primary tumor and affected lymph node compartments. This working group was charged by the Surgical Affairs Committee of the American Thyroid Association to examine the available literature and to review the most appropriate imaging studies for the planning of initial and revision surgery for thyroid cancer. Summary: Ultrasound remains the most important imaging modality in the evaluation of thyroid cancer, and should be used routinely to assess both the primary tumor and all associated cervical lymph node basins preoperatively. Positive lymph nodes may be distinguished from normal nodes based upon size, shape, echogenicity, hypervascularity, loss of hilar architecture, and the presence of calcifications. Ultrasound-guided fine-needle aspiration of suspicious lymph nodes may be useful in guiding the extent of surgery. Cross-sectional imaging (computed tomography with contrast or magnetic resonance imaging) may be considered in select circumstances to better characterize tumor invasion and bulky, inferiorly located, or posteriorly located lymph nodes, or when ultrasound expertise is not available. The above recommendations are applicable to both initial and revision surgery. Functional imaging with positron emission tomography (PET) or PET-CT may be helpful in cases of recurrent cancer with positive tumor markers and negative anatomic imaging. PMID:25188202
MO-FG-210-00: US Guided Systems for Brachytherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
Ultrasound (US) is one of the most widely used imaging modalities in medical practice. Since US imaging offers real-time imaging capability, it has becomes an excellent option to provide image guidance for brachytherapy (IGBT). (1) The physics and the fundamental principles of US imaging are presented, and the typical steps required to commission an US system for IGBT is provided for illustration. (2) Application of US for prostate HDR brachytherapy, including partial prostate treatments using MR-ultrasound co-registration to enable a focused treatment on the disease within the prostate is also presented. Prostate HDR with US image guidance planning can benefitmore » from real time visualization of the needles, and fusion of the ultrasound images with T2 weighted MR allows the focusing of the treatment to the specific areas of disease within the prostate, so that the entire gland need not be treated. Finally, (3) ultrasound guidance for an eye plaque program is presented. US can be a key component of placement and QA for episcleral plaque brachytherapy for ocular cancer, and the UCLA eye plaque program with US for image guidance is presented to demonstrate the utility of US verification of plaque placement in improving the methods and QA in episcleral plaque brachytherapy. Learning Objectives: To understand the physics of an US system and the necessary aspects of commissioning US for image guided brachytherapy (IGBT). To understand real time planning of prostate HDR using ultrasound, and its application in partial prostate treatments using MR-ultrasound fusion to focus treatment on disease within the prostate. To understand the methods and QA in applying US for localizing the target and the implant during a episcleral plaque brachytherapy procedures.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lamb, J.
2015-06-15
Ultrasound (US) is one of the most widely used imaging modalities in medical practice. Since US imaging offers real-time imaging capability, it has becomes an excellent option to provide image guidance for brachytherapy (IGBT). (1) The physics and the fundamental principles of US imaging are presented, and the typical steps required to commission an US system for IGBT is provided for illustration. (2) Application of US for prostate HDR brachytherapy, including partial prostate treatments using MR-ultrasound co-registration to enable a focused treatment on the disease within the prostate is also presented. Prostate HDR with US image guidance planning can benefitmore » from real time visualization of the needles, and fusion of the ultrasound images with T2 weighted MR allows the focusing of the treatment to the specific areas of disease within the prostate, so that the entire gland need not be treated. Finally, (3) ultrasound guidance for an eye plaque program is presented. US can be a key component of placement and QA for episcleral plaque brachytherapy for ocular cancer, and the UCLA eye plaque program with US for image guidance is presented to demonstrate the utility of US verification of plaque placement in improving the methods and QA in episcleral plaque brachytherapy. Learning Objectives: To understand the physics of an US system and the necessary aspects of commissioning US for image guided brachytherapy (IGBT). To understand real time planning of prostate HDR using ultrasound, and its application in partial prostate treatments using MR-ultrasound fusion to focus treatment on disease within the prostate. To understand the methods and QA in applying US for localizing the target and the implant during a episcleral plaque brachytherapy procedures.« less
NASA Astrophysics Data System (ADS)
Xia, Wenfeng; West, Simeon J.; Nikitichev, Daniil I.; Ourselin, Sebastien; Beard, Paul C.; Desjardins, Adrien E.
2016-03-01
Accurate identification of tissue structures such as nerves and blood vessels is critically important for interventional procedures such as nerve blocks. Ultrasound imaging is widely used as a guidance modality to visualize anatomical structures in real-time. However, identification of nerves and small blood vessels can be very challenging, and accidental intra-neural or intra-vascular injections can result in significant complications. Multi-spectral photoacoustic imaging can provide high sensitivity and specificity for discriminating hemoglobin- and lipid-rich tissues. However, conventional surface-illumination-based photoacoustic systems suffer from limited sensitivity at large depths. In this study, for the first time, an interventional multispectral photoacoustic imaging (IMPA) system was used to image nerves in a swine model in vivo. Pulsed excitation light with wavelengths in the ranges of 750 - 900 nm and 1150 - 1300 nm was delivered inside the body through an optical fiber positioned within the cannula of an injection needle. Ultrasound waves were received at the tissue surface using a clinical linear array imaging probe. Co-registered B-mode ultrasound images were acquired using the same imaging probe. Nerve identification was performed using a combination of B-mode ultrasound imaging and electrical stimulation. Using a linear model, spectral-unmixing of the photoacoustic data was performed to provide image contrast for oxygenated and de-oxygenated hemoglobin, water and lipids. Good correspondence between a known nerve location and a lipid-rich region in the photoacoustic images was observed. The results indicate that IMPA is a promising modality for guiding nerve blocks and other interventional procedures. Challenges involved with clinical translation are discussed.
Primdahl, Stine C; Todsen, Tobias; Clemmesen, Louise; Knudsen, Lars; Weile, Jesper
2016-09-21
Peripheral vascular access is vital for treatment and diagnostics of hospitalized patients. Ultrasound-guided vascular access (UGVA) is superior to the landmark technique. To ensure competence-based education, an assessment tool of UGVA competence is needed. We aimed to develop a global rating scale (RS) for assessment of UGVA competence based on opinions on the content from ultrasound experts in a modified Delphi consensus study. We included experts from anesthesiology, emergency medicine and radiology across university hospitals in Denmark. Nine elements were drafted based on existing literature and recommendations from international societies. In a multi-round survey, the experts rated the elements on a five-point Likert scale according to importance, and suggested missing elements. The final Delphi round occurred when >80% of the experts rated all elements ≥4 on the Likert scale. Sixteen experts consented to participate in the study, one withdrew consent prior to the first Delphi round, and 14 completed all three Delphi rounds. In the first Delphi round the experts excluded one element from the scale and changed the content of two elements. In the second Delphi round, the experts excluded one element from the scale. In the third Delphi round, consensus was obtained on the eight elements: preparation of utensils, ergonomics, preparation of the ultrasound device, identification of blood vessels, anatomy, hygiene, coordination of the needle, and completion of the procedure. We developed an RS for assessment of UGVA competence based on opinions of ultrasound experts through a modified Delphi consensus study.
Wijlemans, Joost W; de Greef, Martijn; Schubert, Gerald; Moonen, Chrit T W; van den Bosch, Maurice A A J; Ries, Mario
2014-12-01
Magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) ablation of tumors in the liver dome is challenging because of the presence of air in the costophrenic angle. In this study, we used a porcine liver model and a clinical MR-HIFU system to assess the feasibility and safety of using intrapleural fluid infusion (IPI) to create an acoustic window for MR-HIFU ablation in the liver dome. Healthy adult Dalland land pigs (n = 6) under general anesthesia were used with animal committee approval. Degassed saline (200-800 mL) was infused into the intrapleural space under ultrasound guidance. A clinical 1.5-T MR-HIFU system was used to perform sonications (4-mm treatment cells, 300-450 W, 20-30 seconds) in the liver dome under real-time MR thermometry. An intercostal firing technique was used to prevent rib heating in one experiment. Technical success was defined as a temperature increase (>10°C) in the target area. After termination, the animal was examined for thermal damage to liver, diaphragm, pleura, lung, or intercostal muscle. An acoustic window was established in all animals. A temperature increase in the target area was achieved in all animals (max. 47°C-67°C). MR thermometry showed no heating outside the target area. Intercostal firing effectively reduced rib heating (55°C vs. 42°C). Postmortem examination revealed no unwanted thermal damage. One complication occurred, in the first experiment, because of an ill-suited needle (displacement of the needle). The results indicate that IPI may be used safely to assist MR-HIFU ablation of tumors in the liver dome. For reliable tissue coagulation, IPI must be combined with an intercostal sonication technique. Considering the proportion of patients with tumors in the liver dome, IPI widens the applicability of MR-HIFU ablation for liver tumors considerably. Copyright © 2014 AUR. Published by Elsevier Inc. All rights reserved.
2010-01-01
Background Analysis of gene expression and gene mutation may add information to be different from ordinary pathological tissue diagnosis. Since samples obtained endoscopically are very small, it is desired that more sensitive technology is developed for gene analysis. We investigated whether gene expression and gene mutation analysis by newly developed ultra-sensitive three-dimensional (3D) microarray is possible using small amount samples from endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) specimens and pancreatic juices. Methods Small amount samples from 17 EUS-FNA specimens and 16 pancreatic juices were obtained. After nucleic acid extraction, the samples were amplified with labeling and analyzed by the 3D microarray. Results The analyzable rate with the microarray was 46% (6/13) in EUS-FNA specimens of RNAlater® storage, and RNA degradations were observed in all the samples of frozen storage. In pancreatic juices, the analyzable rate was 67% (4/6) in frozen storage samples and 20% (2/10) in RNAlater® storage. EUS-FNA specimens were classified into cancer and non-cancer by gene expression analysis and K-ras codon 12 mutations were also detected using the 3D microarray. Conclusions Gene analysis from small amount samples obtained endoscopically was possible by newly developed 3D microarray technology. High quality RNA from EUS-FNA samples were obtained and remained in good condition only using RNA stabilizer. In contrast, high quality RNA from pancreatic juice samples were obtained only in frozen storage without RNA stabilizer. PMID:20416107
Ultrasound-guided core biopsy in the diagnosis of lymphoma of the head and neck. A 9 year experience
Burke, C; Thomas, R; Inglis, C; Baldwin, A; Ramesar, K; Grace, R; Howlett, D C
2011-01-01
Objectives This retrospective study aimed to evaluate the diagnostic utility of ultrasound-guided core biopsy (USCB) in lymphoma of the head and neck, in particular whether core biopsy can provide sufficient diagnostic information for definitive treatment. Methods All lymphomas diagnosed in the head and neck at Eastbourne General Hospital between January 2000 and June 2009 were identified. Radiology and pathology reports were reviewed and the diagnostic techniques recorded. The type of biopsy (fine needle aspiration, needle core, surgical excision biopsy) used to establish a diagnosis sufficient to allow treatment, i.e. the "index" diagnostic technique, was identified. Previous inconclusive or inadequate biopsies were noted. Pathology reports based on USCB were graded 0–3 according to diagnostic completeness and ability to provide treatment information. Results Of 691 overall cases of lymphoma diagnosed over the 9 year period, 171 different patients presented with lymphoma in the head and neck. Of these 171, 83 had USCB biopsy during diagnostic work up. 60 were regarded as grade 3 where a confident diagnosis of lymphoma was made. In seven patients, clinical management proceeded on the basis of a suggestive (grade 2) pathology report without surgical excision, and these were therefore also included as "index" biopsies. Overall therefore, 67/83 core biopsies (81%) provided adequate information to allow treatment. Surgical excision biopsy was the index modality in 104 cases. Conclusion In the majority of cases USCB is adequate for confident histopathological diagnosis avoiding the need for surgical excision biopsy in cases of suspected head and neck lymphoma. PMID:21427181
Chatzipantelis, Paschalis; Salla, Charitini; Apostolou, George; Christodoulou, Lambrini; Kakiopoulos, George; Patralexis, Charalambos
2010-01-01
Solid pseudopapillary tumor of the pancreas (SPTP) is an exceedingly rare pancreatic tumor. We present the clinical, endoscopic ultrasound (EUS)-guided fine needle aspiration (FNA) cytologic features and immunohistochemical findings performed on cell blocks of 3 SPTPs. Three females (17-32 years old) were admitted to our hospital due to unexplained episodic abdominal pain. EUS confirmed the presence of a mass in the body and tail of the pancreas (2 cases) and in the head (1 case), with distinct borders and occassional dilation of the peripheral part of the pancreatic duct. EUS-FNA cytology specimens consisted of single cells and aggregates of uniform polyhedral cells, forming branching papillary clusters with delicate fibrovascular cores and nuclear overlapping (2 cases) and glandlike structures (1 case). Variable hyaline, myxoid stromal elements and naked capillaries were also seen. The cells had bland nuclear features, small nucleoli, nuclear grooves in some of them and focally cytoplasmic projections. Mitoses and necrosis were not observed. The immunohistochemistry on cell blocks revealed: vimentin+ (3 cases), CA19.9+ (2 cases), cytokeratin 7+ (focal, intensive, 1 case), synaptophysin+ (1 case), MUC1+ (focal, intensive, 1 case), EMA+ (diffuse weak, 1 case), a1-antitrypsin and a1-antichymotrypsin+ (focal intensive, 2 cases), progesterone+ (1 case), chromogranin-A- (3 cases) and NSE- (3 cases). Cytologic and immunohistochemical findings were strongly suggestive of SPTP. Surgical resection confirmed the diagnosis in all cases. EUS-FNA cytology features and immunohistochemistry provide the diagnosis of SPTP with accuracy.
NASA Astrophysics Data System (ADS)
Bhattad, Srikanth; Escoto, Abelardo; Malthaner, Richard; Patel, Rajni
2015-03-01
Brachytherapy and thermal ablation are relatively new approaches in robot-assisted minimally invasive interventions for treating malignant tumors. Ultrasound remains the most favored choice for imaging feedback, the benefits being cost effectiveness, radiation free, and easy access in an OR. However it does not generally provide high contrast, noise free images. Distortion occurs when the sound waves pass through a medium that contains air and/or when the target organ is deep within the body. The distorted images make it quite difficult to recognize and localize tumors and surgical tools. Often tools, such as a bevel-tipped needle, deflect from its path during insertion, making it difficult to detect the needle tip using a single perspective view. The shifting of the target due to cardiac and/or respiratory motion can add further errors in reaching the target. This paper describes a comprehensive system that uses robot dexterity to capture 2D ultrasound images in various pre-determined modes for generating 3D ultrasound images and assists in maneuvering a surgical tool. An interactive 3D virtual reality environment is developed that visualizes various artifacts present in the surgical site in real-time. The system helps to avoid image distortion by grabbing images from multiple positions and orientation to provide a 3D view. Using the methods developed for this application, an accuracy of 1.3 mm was achieved in target attainment in an in-vivo experiment subjected to tissue motion. An accuracy of 1.36 mm and 0.93 mm respectively was achieved for the ex-vivo experiments with and without external induced motion. An ablation monitor widget that visualizes the changes during the complete ablation process and enables evaluation of the process in its entirety is integrated.
Park, Young Mi; Fornage, Bruno D; Benveniste, Ana Paula; Fox, Patricia S; Bassett, Roland L; Yang, Wei Tse
2014-12-01
The purpose of this study was to determine the diagnostic value of strain elastography (SE) alone and in combination with gray-scale ultrasound in the diagnosis of benign versus metastatic disease for abnormal axillary lymph nodes in breast cancer patients. Patients with breast cancer and axillary lymph nodes suspicious for metastatic disease on conventional ultrasound who underwent SE of the suspicious node before ultrasound-guided fine-needle aspiration biopsy (FNAB) were included in this study. On conventional ultrasound, the long- and short-axis diameters, long-axis-to-short-axis ratio, cortical echogenicity, thickness, and evenness were documented. The nodal vascularity was assessed on power Doppler imaging. Elastograms were evaluated for the percentage of black (hard) areas in the lymph node, and the SE-ultrasound size ratio was calculated. Two readers assessed the images independently and then in consensus in cases of disagreement. ROC AUCs were calculated for conventional ultrasound, SE, and both methods combined. Interreader reliability was assessed using kappa statistics. A total of 101 patients with 104 nodes were examined; 35 nodes were benign, and 69 had metastases. SE alone showed a significantly lower AUC (62%) than did conventional ultrasound (92%) (p<0.001). There was no difference between the AUC of conventional ultrasound and the AUC of the combination of conventional ultrasound and SE (93%) (p=0.16). Interreader reliability was moderate for all variables (κ≥0.60) except the SE-ultrasound size ratio (κ=0.35). Added SE does not improve the diagnostic ability of conventional ultrasound when evaluating abnormal axillary lymph nodes.
Needle echogenicity in ultrasound-guided lumbar spine injections: a cadaveric study.
Gofeld, Michael; Krashin, Daniel L; Ahn, Sangmin
2013-01-01
Echogenicity of regional anesthesia needles has been tested on different preclinical models; however, previous studies were done in an ideal experimental setting utilizing high-frequency insonation and superficially located targets. Because steep-angle deep injections are typically required for spinal and other chronic pain procedures, and low-frequency transducers are used, further feasibility study is warranted. To determine effectiveness of steep-angle deep injections, typically required for spinal and other chronic pain procedures. Experimental laboratory study. Willed Body Program, University of Washington. In-plane lumbar spine procedures with 50° and 70° angles were performed on a human cadaver. The images and video clips of a non-echogenic (Quincke-type) and echogenic (SonoPlex, StimuQuick, and EchoStim) needle placements were presented to 3 blinded assessors who rated the needle visibility on a 4-point scale. The data was statistically analyzed to determine the differences in visibility between the needles with and without the digital image enhancement, and to compare the video clips to captured images. ANOVA analysis demonstrated that overall SonoPlex was significantly better (P = 0.02) than other needles. SonoPlex maintained its superiority in the subset of facet joint injections (P = 0.02), followed by Quincke-type, then the StimuQuik, and EchoStim needles. In deep procedures, EchoStim was comparable with SonoPlex (P = 0.03), and they both were better than the other 2 needles. The enhanced images received higher rates, with a 0.6 point mean improved rating (P = 0). This study is limited by choice of needles, number of experiments performed, and potential postmortem changes of echogenicity. The SonoPlex needle appeared to have better echogenicity in this study. While non-echogenic Quincke-type needle visibility was adequate in superficial placements, it was limited in deep injections. An imaging enhancement is effective in improving needle visibility and should be used whenever possible.
Lateral orbitotomy for treatment of an orbital abscess in a dog.
Vallefuoco, R; Molas, C; Moissonnier, P; Chahory, S
2014-10-01
A two-year-old Jack Russell terrier was diagnosed with a retrobulbar abscess and orbital cellulitis. The diagnosis was confirmed by ultrasound, magnetic resonance imaging examination and ultrasound-guided fine-needle aspiration. Transoral ventral drainage was attempted but was unsuccessful. The abscess was successfully treated by open drainage through a lateral orbitotomy. Despite the exposure of the orbital structures, the orbital soft tissues healed by second intention without further complications. The open drainage was well tolerated and resulted in immediate reduction of inflammation and pain, allowing a quick recovery. This report describes the diagnosis and, surgical management and the long-term (3 years) follow-up of an unusual case of orbital abscess associated with diffuse periorbital cellulitis successfully treated by open drainage through a lateral orbitotomy. © 2014 British Small Animal Veterinary Association.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kapoor, P; Kapoor, R; Curran, B
Purpose: To analyze the impact on acoustic velocity (AV) of two different media (water and milk) using the needle template/electronic grid alignment test. Water, easily available, makes a good material to test the alignment of the template and grid although water’s AV (1498 m/s at 25°C) is significantly different from tissue (1540 m/s). Milk, with an AV much closer (1548 m/s) to prostate tissue, may be a good substitute for water in ultrasound quality assurance testing. Methods: Tests were performed using a Hitachi ultrasound unit with a mechanical arrangement designed to position needles parallel to the transducer. In this work,more » two materials – distilled water and homogenized whole milk (AVs of 1498 and 1548 m/s at 25°C) were used in a phantom to test ultrasound needle/grid alignment. The images were obtained with both materials and analyzed for their placement accuracy. Results: The needle template/electronic grid alignment tests showed displacement errors between measured and calculated values. The measurements showed displacements of 2.3mm (water) and 0.4mm (milk), and 1.6mm (water) and 0.3mm (milk) at depths of 7cm and 5cm respectively from true needle positions. The calculated results showed a displacement of 2.36 mm (water); 0.435mm (milk), and 1.66mm (water) and 0.31mm (milk) at a depth of 7cm and 5cm respectively. The displacements in the X and Y directions were also calculated. At depths of 7cm and 5cm, the (ΔX,ΔY) displacements in water were (0.829mm, 2.21mm) and (0.273mm, 1.634mm) and for milk were (0.15mm, 0.44mm) and (0.05mm, 0.302mm) respectively. Conclusion: The measured and calculated values were in good agreement for all tests. They show that milk provides superior results when performing needle template and electronic grid alignment tests for ultrasound units used in prostate brachytherapy.« less
Arnuntasupakul, Vanlapa; Chalachewa, Theerawat; Leurcharusmee, Prangmalee; Tiyaprasertkul, Worakamol; Finlayson, Roderick J; Tran, De Q
2018-03-01
Ultrasound-guided lumbar plexus blocks usually require confirmatory neurostimulation. A simpler alternative is to inject local anaesthetic inside the posteromedial quadrant of the psoas muscle under ultrasound guidance. We hypothesised that both techniques would result in similar total anaesthesia time, defined as the sum of performance and onset time. A randomised, observer-blinded, equivalence trial. Ramathibodi Hospital and Maharaj Nakorn Chiang Mai Hospital (Thailand) from 12 May 2016 to 10 January 2017. A total of 110 patients undergoing total hip or knee arthroplasty, who required lumbar plexus block for postoperative analgesia. In the combined ultrasonography-neurostimulation group, quadriceps-evoked motor response was sought at a current between 0.2 and 0.8 mA prior to local anaesthetic injection (30 ml of lidocaine 1% and levobupivacaine 0.25% with epinephrine 5 μg ml and 5 mg of dexamethasone). In the ultrasound guidance alone group, local anaesthetic was simply injected inside the posteromedial quadrant of the psoas muscle. We measured the total anaesthesia time, the success rate (at 30 min), the number of needle passes, block-related pain, cumulative opioid consumption (at 24 h) and adverse events (vascular puncture, paraesthesia, local anaesthetic spread to the epidural space). The equivalence margin was 7.4 min. Compared with ultrasound guidance alone, combined ultrasonography-neurostimulation resulted in decreased mean (±SD) total anaesthesia time [15.3 (±6.5) vs. 20.1 (±9.0) min; mean difference, -4.8; 95% confidence interval, -8.1 to -1.9; P = 0.005] and mean (±SD) onset time [10.2 (±5.6) vs. 15.5 (±9.0) min; P = 0.004). No inter-group differences were observed in terms of success rate, performance time, number of needle passes, block-related pain, opioid consumption or adverse events. Although the ultrasonography-neurostimulation technique results in a shorter total anaesthesia time compared with ultrasound guidance alone, this difference falls within our accepted equivalence margin (±7.4 min). www.clinicaltrials in the (Study ID: TCTR20160427003).
Fine-needle aspiration cytology of intraductal papillary-mucinous tumors: a retrospective analysis.
Layfield, Lester J; Cramer, Harvey
2005-01-01
Intraductal papillary-mucinous tumor (IPMT) of the pancreas has become the accepted terminology for a group of mucin-producing epithelial proliferations lying within ectatic segments of the main pancreatic duct or its large branches. These neoplasms generally are associated with an indolent course, characteristic endoscopic ultrasonographic (EUS) findings, and a variable histo- and cytomorphology ranging from hyperplasia to carcinoma. Cytological specimens obtained by endoscopic ultrasound-guided or percutaneous fine-needle aspiration (FNA) are characterized by a background containing abundant mucin in which are entrapped single or loosely cohesive clusters of neoplastic cells characteristically showing a goblet-cell morphology. The degree of nuclear atypia, cell crowding, and cell shape varies between smears within a single case and between cases. Cytomorphological examination, when coupled with EUS features, is accurate for the diagnosis of these lesions but often it underdiagnoses the grade of the neoplasm. (c) 2005 Wiley-Liss, Inc.
Xiao, Li-Hong; Chen, Pei-Ran; Gou, Zhong-Ping; Li, Yong-Zhong; Li, Mei; Xiang, Liang-Cheng; Feng, Ping
2017-01-01
The aim of this study is to evaluate the ability of the random forest algorithm that combines data on transrectal ultrasound findings, age, and serum levels of prostate-specific antigen to predict prostate carcinoma. Clinico-demographic data were analyzed for 941 patients with prostate diseases treated at our hospital, including age, serum prostate-specific antigen levels, transrectal ultrasound findings, and pathology diagnosis based on ultrasound-guided needle biopsy of the prostate. These data were compared between patients with and without prostate cancer using the Chi-square test, and then entered into the random forest model to predict diagnosis. Patients with and without prostate cancer differed significantly in age and serum prostate-specific antigen levels (P < 0.001), as well as in all transrectal ultrasound characteristics (P < 0.05) except uneven echo (P = 0.609). The random forest model based on age, prostate-specific antigen and ultrasound predicted prostate cancer with an accuracy of 83.10%, sensitivity of 65.64%, and specificity of 93.83%. Positive predictive value was 86.72%, and negative predictive value was 81.64%. By integrating age, prostate-specific antigen levels and transrectal ultrasound findings, the random forest algorithm shows better diagnostic performance for prostate cancer than either diagnostic indicator on its own. This algorithm may help improve diagnosis of the disease by identifying patients at high risk for biopsy.
Kang, Hyo Jae; Hwangbo, Bin; Lee, Jin Soo; Kim, Moon Soo; Lee, Jong Mog; Lee, Geon-Kook
2016-01-01
Introduction Although the use of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is increasing for epidermal growth factor receptor (EGFR) testing in lung cancer, the discordance rate in EGFR mutations between lymph node (LN) samples obtained by EBUS-TBNA and primary tumor (PT) is not well known. Thus, we compared the EGFR mutation status of LN samples obtained by EBUS-TBNA and PTs to estimate the efficacy of using EBUS-TBNA specimens for EGFR testing in advanced, non-squamous, non-small cell lung cancer (NSCLC). Materials and Methods Using data of patients from the EBUS-TBNA database (N = 1914) obtained between January 2009 and January 2013, we identified 100 treatment-naïve, advanced, non-squamous NSCLC patients (stage 3 and 4) with matched LN specimens obtained by EBUS-TBNA and PT specimens. Of these, 74 patients with paired specimens were feasible for EGFR mutation analysis, which we performed using a direct sequencing method. Results Of the 74 cases, at least one major [exon 19 deleted (19del) and L858R] or minor (T790M, exon 20 insertion, and other point mutations) EGFR mutation was detected in 31 cases (41.9%), which included PT (n = 31, 41.9%) and LN (n = 28, 37.8%) specimens. Major mutations were detected in 25 PT (33.8%, 19del = 13, L858R = 12) and 22 LN (29.8%, 19del = 11, L858R = 11) specimens. The discordance rate in major mutations between matched PT and LN specimens was 4.1% (3/74). Among minor mutations, T790M was detected in LN specimen only in 2 cases with L858R in PT and LN. The discordance rate major and minor EGFR mutations combined between matched PT and LN specimens was 12% (9/74). Conclusions We observed a high concordance rate of major EGFR mutations between matched LN specimens sampled by EBUS-TBNA and PTs, suggesting that LN samples obtained by EBUS-TBNA from advanced non-squamous NSCLC patients are effective for use in EGFR mutation testing. PMID:27685950
Mallorie, Amy; Goldring, James; Patel, Anant; Lim, Eric; Wagner, Thomas
2017-08-01
Lymph node involvement in non-small-cell lung cancer (NSCLC) is a major factor in determining management and prognosis. We aimed to evaluate the accuracy of fluorine-18-fluorodeoxyglucose-PET/computed tomography (CT) for the assessment of nodal involvement in patients with NSCLC. In this retrospective study, we included 61 patients with suspected or confirmed resectable NSCLC over a 2-year period from April 2013 to April 2015. 221 nodes with pathological staging from surgery or endobronchial ultrasound-guided transbronchial needle aspiration were assessed using a nodal station-based analysis with original clinical reports and three different cut-offs: mediastinal blood pool (MBP), liver background and tumour standardized uptake value maximal (SUVmax)/2. Using nodal station-based analysis for activity more than tumour SUVmax/2, the sensitivity was 45%, the specificity was 89% and the negative predictive value (NPV) was 87%. For activity more than MBP, the sensitivity was 93%, the specificity was 72% and NPV was 98%. For activity more than liver background, the sensitivity was 83%, the specificity was 84% and NPV was 96%. Using a nodal staging-based analysis for accuracy at detecting N2/3 disease, for activity more than tumour SUVmax/2, the sensitivity was 59%, the specificity was 85% and NPV was 80%. For activity more than MBP, the sensitivity was 95%, the specificity was 61% and NPV was 96%. For activity more than liver background, the sensitivity was 86%, the specificity was 81% and NPV was 92%. Receiver-operating characteristic analysis showed the optimal nodal SUVmax to be more than 6.4 with a sensitivity of 45% and a specificity of 95%, with an area under the curve of 0.85. Activity more than MBP was the most sensitive cut-off with the highest sensitivity and NPV. Activity more than primary tumour SUVmax/2 was the most specific cut-off. Nodal SUVmax more than 6.4 has a high specificity of 95%.
Analysis of EML4-ALK rearrangement in non-small cell lung cancer in Argentina.
Verzura, María; Batagelj, Emilio; Bagnes, Claudia; Martin, Claudio; Enrico, Diego; Richardet, Eduardo; De la Iglesia, Paola
2018-02-26
Identification of EML4-ALK rearrangement by FISH test has become standard in advanced NSCLC patients. There is limited information about the prevalence and clinical characteristics of ALK translocation in Latin America. The aim of our study was to evaluate this lung cancer subtype features in Argentinian patients and the factibility of FISH test with different methods used for obtaining tissue samples. Between August 2014 and February 2017, 183 non-squamous NSCLC patients were prospectively enrolled from five Argentinian institutions. Different techniques and procedures were used to obtained tissue samples material. ALK determination was performed by FISH and immunohistochemistry (IHC). Correlation with clinico-pathological information and different biopsy procedures was assessed. From 183 non-squamous NSCLC samples, 131 could perform FISH test, finding 123 (93.9%) negative and 8 (6.1%) positive patients. Fifty-one samples were not evaluable by FISH, 35 because of technical problems and 16 due to not/weak signal. The difficulties in obtaining adequate FISH tests were observed significantly more frequently for fine-needle aspiration (FNA) and core-needle biopsy than for excisional and incisional biopsy (p = 0.009). Regarding the procedures, surgery was the most efficient, obtaining only 12.7% (10/79) of not evaluable samples for FISH, while CT guided biopsy and transbronchial biopsy (TBB) failed in 43.8% (21/48) and 41.3% (19/46) of patients respectively (p < 0.001). We observed a significant association between ALK translocation and never smoking habit (p = 0.004). Our ALK rearrangements frequency (6.1%) was similar to the reports worldwide. One of the major determinants for the ALK FISH test success is the quality of the tissue sample obtained. Copyright © 2018 Elsevier Inc. All rights reserved.
Blumenfeld, Philip; Hata, Nobuhiko; DiMaio, Simon; Zou, Kelly; Haker, Steven; Fichtinger, Gabor; Tempany, Clare M C
2007-09-01
To quantify needle placement accuracy of magnetic resonance image (MRI)-guided core needle biopsy of the prostate. A total of 10 biopsies were performed with 18-gauge (G) core biopsy needle via a percutaneous transperineal approach. Needle placement error was assessed by comparing the coordinates of preplanned targets with the needle tip measured from the intraprocedural coherent gradient echo images. The source of these errors was subsequently investigated by measuring displacement caused by needle deflection and needle susceptibility artifact shift in controlled phantom studies. Needle placement error due to misalignment of the needle template guide was also evaluated. The mean and standard deviation (SD) of errors in targeted biopsies was 6.5 +/- 3.5 mm. Phantom experiments showed significant placement error due to needle deflection with a needle with an asymmetrically beveled tip (3.2-8.7 mm depending on tissue type) but significantly smaller error with a symmetrical bevel (0.6-1.1 mm). Needle susceptibility artifacts observed a shift of 1.6 +/- 0.4 mm from the true needle axis. Misalignment of the needle template guide contributed an error of 1.5 +/- 0.3 mm. Needle placement error was clinically significant in MRI-guided biopsy for diagnosis of prostate cancer. Needle placement error due to needle deflection was the most significant cause of error, especially for needles with an asymmetrical bevel. (c) 2007 Wiley-Liss, Inc.
Sanz-Santos, José; Serra, Pere; Torky, Mohamed; Andreo, Felipe; Centeno, Carmen; Mendiluce, Leire; Martínez-Barenys, Carlos; López de Castro, Pedro; Ruiz-Manzano, Juan
2018-04-06
To evaluate the accuracy of systematic mediastinal staging by endobronchial ultrasound transbronchial needle aspiration (EBUS-TBNA) (sampling of all visible nodes measuring ≥5mm from stations N3 to N1 regardless of their positron emission tomography/computed tomography (PET/CT) features) and compare this staging approach with targeted EBUS-TBNA staging (sampling only 18F-fluorodeoxyglucose (FDG)-avid nodes) in patients with N2 non-small cell lung cancer (NSCLC) on PET/CT. Retrospective study of 107 patients who underwent systematic EBUS-TBNA mediastinal staging. The results were compared with those of a hypothetical scenario where only FDG-avid nodes on PET/CT would be sampled. Systematic EBUS-TBNA sampling demonstrated N3 disease in 3 patients, N2 disease in 60 (42 single-station or N2a, 18 multiple-station or N2b) and N0/N1 disease in 44. Of these 44, seven underwent mediastinoscopy, which did not show mediastinal disease; six of the seven proceeded to lung resection, which also showed no mediastinal disease. Thirty-four N0/N1 patients after EBUS-TBNA underwent lung resection directly: N0/N1 was found in 30 and N2 in four (one N2b with a PET/CT showing N2a disease, three N2a). Sensitivity, specificity, negative predictive value, positive predictive value, and overall accuracy of systematic EBUS-TBNA were 94%, 100%, 90%, 100% and 96%, respectively. Compared to targeted EBUS-TBNA, systematic EBUS-TBNA sampling provided additional important clinical information in 14 cases (13%): three N3 cases would have passed unnoticed, and 11 N2b cases would have been staged as N2a. In clinical practice, systematic sampling of the mediastinum by EBUS-TBNA, regardless of PET/CT features, is to be recommended over targeted sampling. Copyright © 2018. Published by Elsevier Inc.
Fortmeier, Dirk; Mastmeyer, Andre; Schröder, Julian; Handels, Heinz
2016-01-01
This study presents a new visuo-haptic virtual reality (VR) training and planning system for percutaneous transhepatic cholangio-drainage (PTCD) based on partially segmented virtual patient models. We only use partially segmented image data instead of a full segmentation and circumvent the necessity of surface or volume mesh models. Haptic interaction with the virtual patient during virtual palpation, ultrasound probing and needle insertion is provided. Furthermore, the VR simulator includes X-ray and ultrasound simulation for image-guided training. The visualization techniques are GPU-accelerated by implementation in Cuda and include real-time volume deformations computed on the grid of the image data. Computation on the image grid enables straightforward integration of the deformed image data into the visualization components. To provide shorter rendering times, the performance of the volume deformation algorithm is improved by a multigrid approach. To evaluate the VR training system, a user evaluation has been performed and deformation algorithms are analyzed in terms of convergence speed with respect to a fully converged solution. The user evaluation shows positive results with increased user confidence after a training session. It is shown that using partially segmented patient data and direct volume rendering is suitable for the simulation of needle insertion procedures such as PTCD.
Rossi, Esther Diana; Larghi, Alberto; Verna, Elizabeth C; Martini, Maurizio; Galasso, Domenico; Carnuccio, Antonella; Larocca, Luigi Maria; Costamagna, Guido; Fadda, Guido
2010-11-01
The diagnosis subtyping of lymphoma on specimens collected by endoscopic ultrasound fine-needle aspiration (EUS-FNA) can be extremely difficult. When a cytopathologist is available for the on-site evaluation, the diagnosis may be achieved by applying flow cytometric techniques. We describe our experience with immunocytochemistry (ICC) and molecular biology studies applied on EUS-FNA specimens processed with a liquid-based cytologic (LBC) preparation for the diagnosis of primary pancreatic lymphoma (PPL). Three patients with a pancreatic mass underwent EUS-FNA. The collected specimens were processed with the ThinPrep method for the cytologic diagnosis and eventual additional investigations. A morphologic picture consistent with PPL was found on the LBC specimens of the 3 patients. Subsequent ICC and molecular biology studies for immunoglobulin heavy chain gene rearrangement established the diagnosis of pancreatic large B-cell non-Hodgkin lymphoma in 2 patients and a non-Hodgkin lymphoma with plasmoblastic/immunoblastic differentiation in the remaining one. An LBC preparation can be used to diagnose and subtype PPL by applying ICC and molecular biology techniques to specimens collected with EUS-FNA. This method can be an additional processing method for EUS-FNA specimens in centers where on-site cytopathologist expertise is not available.
Wei, Chen-Wei; Nguyen, Thu-Mai; Xia, Jinjun; Arnal, Bastien; Wong, Emily Y; Pelivanov, Ivan M; O'Donnell, Matthew
2015-02-01
Because of depth-dependent light attenuation, bulky, low-repetition-rate lasers are usually used in most photoacoustic (PA) systems to provide sufficient pulse energies to image at depth within the body. However, integrating these lasers with real-time clinical ultrasound (US) scanners has been problematic because of their size and cost. In this paper, an integrated PA/US (PAUS) imaging system is presented operating at frame rates >30 Hz. By employing a portable, low-cost, low-pulse-energy (~2 mJ/pulse), high-repetition-rate (~1 kHz), 1053-nm laser, and a rotating galvo-mirror system enabling rapid laser beam scanning over the imaging area, the approach is demonstrated for potential applications requiring a few centimeters of penetration. In particular, we demonstrate here real-time (30 Hz frame rate) imaging (by combining multiple single-shot sub-images covering the scan region) of an 18-gauge needle inserted into a piece of chicken breast with subsequent delivery of an absorptive agent at more than 1-cm depth to mimic PAUS guidance of an interventional procedure. A signal-to-noise ratio of more than 35 dB is obtained for the needle in an imaging area 2.8 × 2.8 cm (depth × lateral). Higher frame rate operation is envisioned with an optimized scanning scheme.
To fine needle aspiration or not? An endosonographer's approach to pancreatic cystic lesions
But, David Yiu-Kuen; Poley, Jan-Werner
2014-01-01
Endoscopic ultrasound (EUS) guided fine needle aspiration (FNA) is an established diagnostic tool in the management of pancreatic cystic lesions (PCLs). Due to the proximity to the target lesion, the fine diagnostic needle travels through only minimal normal tissues. The risks of bleeding, pancreatitis and infection are small. Valuable diagnostic morphological information can be obtained by EUS before the use of FNA. The additional cytopathologic and cyst fluid analysis for the conventional markers such as amylase, carcinoembryonic antigen (CEA) and CA19.9 improves the diagnostic capability. Pancreatic cyst fluid CEA concentration of 192 ng/mL is generally the most agreed cutoff to differentiate mucinous from non-mucinous lesion. A fluid amylase level of <250 IU/L excludes the diagnosis of pseudocyst. Technical tips of EUS-FNA and the limitations of the procedure are discussed. Promising technique and FNA needle modifications have been described to improve the diagnostic yield at the cytopathologic analysis. The use of novel cyst fluid proteomics and deoxyribonucleic acid-based biomarkers of the PCLs are reviewed. Although it is considered a safe procedure, EUS-FNA is not a routine in every patient. Recommendations of the role of EUS-FNA at various common clinical scenarios are discussed. PMID:24955337
Stevenson, Tracey; Powari, Manish; Bowles, Christopher
2018-05-13
Endobronchial ultrasound fine needle aspiration (EBUS FNA) is a well-established procedure for the diagnosis and staging of lung cancer. We review our provision of this service at the Royal Devon and Exeter NHS Foundation Trust and the role of rapid onsite evaluation (ROSE) with the increasing demand for molecular markers in this era of personalized medicine. A review of the changes in the Endoscopy clinic over the 7 years from the introduction of EBUS at the end of 2010 until 2017 was carried out. This included the availability of material obtained for diagnosis, accurate subtyping, and molecular testing. We also assessed the success of molecular genetics DNA techniques from EBUS material versus formalin fixed paraffin embedded tissue (FFPE). A total of 1218 EBUS cases with ROSE were reported between 2011 and 2017 Percentage diagnostic rates were calculated as 83, 82, 84, 92, 93, 94, and 92 for 2011, 2012, 2013, 2014, 2015, 2016, and 2017, respectively. Availability of material for immunocytochemistry ranged from 86 to 100% over the 7 years. Molecular testing was successfully performed for EGFR in 89-100% of requested cases and ALK testing in 87-100% of requested cases. EBUS sourced material gave on average twice the amount of DNA and fewer amplicon repeats per patient compared to FFPE material. ROSE at EBUS FNA provides access to suitable material for molecular testing with increased yields in the form of needle washings for EGFR with FFPE materials for ALK and PDL1 testing. © 2018 Wiley Periodicals, Inc.
Lin, Li-Wu; Lin, Xue-Ying; He, Yi-Mi; Gao, Shang-Da; Lin, Xiao-Dong
2003-01-01
AIM: To probe the pathological biological characteristics of hepatocellular carcinoma (HCC) by the ultrasound-guided aspiration biopsy and assess the clinical application value of this method. METHODS: The biopsy and DNA analysis by flow cytometry (FCM) were taken in 46 cases with HCC nodules, including 26 cases and 20 cases with nodules ≤ 3 cm and > 3 cm in diameters respectively, and 12 cases with intrahepatic benign hyperplastic nodules. They were taken in 22 cases of 46 cases with HCC before and after the therapy. Fine-needles and automatic histological incised biopsy needles were used. The fresh biopsy tissue was produced into the single cell suspension, which was sent for DNA detection and ratio analysis of cell period. The ratio of each DNA period of cell proliferation of each group was calculated and compared with each other. The DNA aneuploid (AN) and apoptosis cell peak were observed and their percentages were calculated. RESULTS: The ratios of S and G2/M periods of DNA, which reflect cell hyperproliferation, in the group with HCC tumors > 3 cm in diameter were markedly higher than those of the group with HCC nodules ≤ 3 cm in diameter and the group with the benign hyperplastic nodules (P < 0.01 except A:B of S period, P < 0.05). The ratios of the middle group were also apparently higher than those of the latter group (P < 0.01). The ratio of DNA AN of 46 cases with HCC nodules was 34.8% (16/46). None of the cases with the intrahepatic hyperplastic nodules appeared AN. The DNA AN appeared more apparently with the growth of the tumors. The AN ratio of the group with tumors > 3 cm in diameter was 55% (11/20), markedly higher than that of the group with tumors ≤ 3 cm in diameter which was 19.2% (5/26) (P < 0.01). The FCM DNA analysis of 22 specimens of hepatic carcinoma tissue before therapy showed that the aneuploid peaks appeared in 5 cases (22.7%). The ratio of G1 period rose after therapy while the S period and G2/M ratios fell (P < 0.01). The aneuploid peak disappeared in the 5 cases after the therapy, while the apoptosis peaks in 12 cases (54.5%) appeared. CONCLUSION: Addition to supply the information of the pathological morphology of the tumor, the ultrasound-guided fine-needle aspiration tissue could be sent for FCM DNA analysis to comprehend its pathological biological characteristics. This can not only provide the clinic the reliable information about the occurrence, development, diagnosis, curative effect and prognosis of tumors but also supply biological information for clinic to choose therapeutic schemes. PMID:12717834
van der Aa, Anouk A M A; Mannaerts, Christophe K; van der Linden, Hans; Gayet, Maudy; Schrier, Bart Ph; Mischi, Massimo; Beerlage, Harrie P; Wijkstra, Hessel
2018-02-01
To determine the value of a three-dimensional (3D) greyscale transrectal ultrasound (TRUS)-guided prostate biopsy system and biopsy core pre-embedding method on concordance between Gleason scores of needle biopsies and radical prostatectomy (RP) specimens. Retrospective analysis of prostate biopsies and subsequent RP for PCa in the Jeroen Bosch Hospital, the Netherlands, from 2007 to 2016. Two cohorts were analysed: conventional 2D TRUS-guided biopsies and RP (2007-2013, n = 266) versus 3D TRUS-guided biopsies with pre-embedding (2013-2016, n = 129). The impact of 3D TRUS-guidance with pre-embedding on Gleason score (GS) concordance between biopsy and RP was evaluated using the κ-coefficient. Predictors of biopsy GS 6 upgrading were assessed using logistic regression models. Gleason concordance was comparable between the two cohorts with a κ = 0.44 for the 3D cohort, compared to κ = 0.42 for the 2D cohort. 3D TRUS-guidance with pre-embedding, did not significantly affect the risk of biopsy GS 6 upgrading in univariate and multivariate analysis. 3D TRUS-guidance with biopsy core pre-embedding did not improve Gleason concordance. Improved detection techniques are needed for recognition of low-grade disease upgrading.
Jeong, Seung Uk; Aizan, Hassanuddin; Song, Tae Jun; Seo, Dong Wan; Kim, Su-Hui; Park, Do Hyun; Lee, Sang Soo; Lee, Sung Koo; Kim, Myung-Hwan
2013-01-01
AIM: To evaluate the feasibility of diagnostic and therapeutic transgastric (TG) peritoneoscopic interventions with a forward-viewing endoscopic ultrasound (FV-EUS). METHODS: This prospective endoscopic experimental study used an animal model. Combined TG peritoneoscopic interventions and EUS examination of the intra-abdominal organs were performed using an FV-EUS on 10 animal models (1 porcine and 9 canine). The procedures carried out include EUS evaluation and endoscopic biopsy of intraperitoneal organs, EUS-guided fine needle aspiration (EUS-FNA), EUS-guided radiofrequency ablation (EUS-RFA), and argon plasma coagulation (APC) for hemostatic control. The animals were kept alive for 7 d, and then necropsy was performed to evaluate results and complications. RESULTS: In all 10 animals, TG peritoneoscopy, followed by endoscopic biopsy for the liver, spleen, abdominal wall, and omentum, was performed successfully. APC helped control minor bleeding. Visualization of intra-abdominal solid organs with real-time EUS was accomplished with ease. Intraperitoneal EUS-FNA was successfully performed on the liver, spleen, and kidney. Similarly, a successful outcome was achieved with EUS-RFA of the hepatic parenchyma. No adverse events were recorded during the study. CONCLUSION: Peritoneoscopic natural orifice transluminal endoscopic surgery (NOTES) interventions through FV-EUS were feasible in providing evaluation and performing endoscopic procedures. It promises potential as a platform for future EUS-based NOTES. PMID:24222961
Coded excitation ultrasonic needle tracking: An in vivo study.
Xia, Wenfeng; Ginsberg, Yuval; West, Simeon J; Nikitichev, Daniil I; Ourselin, Sebastien; David, Anna L; Desjardins, Adrien E
2016-07-01
Accurate and efficient guidance of medical devices to procedural targets lies at the heart of interventional procedures. Ultrasound imaging is commonly used for device guidance, but determining the location of the device tip can be challenging. Various methods have been proposed to track medical devices during ultrasound-guided procedures, but widespread clinical adoption has remained elusive. With ultrasonic tracking, the location of a medical device is determined by ultrasonic communication between the ultrasound imaging probe and a transducer integrated into the medical device. The signal-to-noise ratio (SNR) of the transducer data is an important determinant of the depth in tissue at which tracking can be performed. In this paper, the authors present a new generation of ultrasonic tracking in which coded excitation is used to improve the SNR without spatial averaging. A fiber optic hydrophone was integrated into the cannula of a 20 gauge insertion needle. This transducer received transmissions from the ultrasound imaging probe, and the data were processed to obtain a tracking image of the needle tip. Excitation using Barker or Golay codes was performed to improve the SNR, and conventional bipolar excitation was performed for comparison. The performance of the coded excitation ultrasonic tracking system was evaluated in an in vivo ovine model with insertions to the brachial plexus and the uterine cavity. Coded excitation significantly increased the SNRs of the tracking images, as compared with bipolar excitation. During an insertion to the brachial plexus, the SNR was increased by factors of 3.5 for Barker coding and 7.1 for Golay coding. During insertions into the uterine cavity, these factors ranged from 2.9 to 4.2 for Barker coding and 5.4 to 8.5 for Golay coding. The maximum SNR was 670, which was obtained with Golay coding during needle withdrawal from the brachial plexus. Range sidelobe artifacts were observed in tracking images obtained with Barker coded excitation, and they were visually absent with Golay coded excitation. The spatial tracking accuracy was unaffected by coded excitation. Coded excitation is a viable method for improving the SNR in ultrasonic tracking without compromising spatial accuracy. This method provided SNR increases that are consistent with theoretical expectations, even in the presence of physiological motion. With the ultrasonic tracking system in this study, the SNR increases will have direct clinical implications in a broad range of interventional procedures by improving visibility of medical devices at large depths.
Francischetti, Ivo M B; Cajigas, Antonio; Suhrland, Mark; Farinhas, Joaquim M; Khader, Samer
2017-08-01
We describe a case of a 41-year old male patient with no significant prior medical history who presents with symptoms of Transient Ischemic Attack and stroke. Magnetic Resonance Imaging (MRI) of the brain identified areas of ischemia in the left side, and angiography showed occlusion of the left Medial Cerebral Artery (MCA). Cardiac Transthoracic Echocardiogram (TTE) for stroke evaluation incidentally noted a mediastinal abnormality leading to cancer work-up. Computer Tomography (CT) and 18 F-fluorodeoxyglucose (FDG) PET-CT scan of the chest incidentally revealed an avid 6 cm paraesophagial/subcarinal mass. Further diagnostic work-up with endoscopic and endobronchial ultra sound (EBUS)-guided fine needle aspiration (FNA) of the mass yielded a cytology diagnosis of Germ Cell Tumor (GCT), with choriocarcinoma component. Additionally, high plasma levels of β-human chorionic gonadotrophin (β-HCG) were detected with no evidence of testicular tumor. This exceedingly rare presentation for a primary mediastinal choriocarcinoma underscores the importance of complete investigation of young patients presenting with neurological symptoms compatible with ischemic events. Diagn. Cytopathol. 2017;45:738-743. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
Cadaveric and Ultrasonographic Validation of Needling Placement in the Cervical Multifidus Muscle.
Fernández-de-Las-Peñas, César; Mesa-Jiménez, Juan A; Paredes-Mancilla, Jose A; Koppenhaver, Shane L; Fernández-Carnero, Samuel
2017-06-01
The aim of this study was to determine if a needle is able to reach the cervical multifidus during the application of dry needling or acupuncture. Dry needling and ultrasound imaging of cervical multifidi was conducted on 5 patients (age: 32 ± 5 years) with mechanical neck pain and on 2 fresh cadavers (age: 64 ± 1 years). Dry needling was done using a needle of 40 mm in length inserted perpendicular to the skin about 1 cm lateral to the spinous process at C3-C4. The needle was advanced from a posterior to anterior direction into the cervical multifidus with a slight inferior-medial angle (approximately 10°) to reach the vertebra lamina. For the cadaveric study, the multifidus was isolated by carefully resecting the superficial posterior cervical muscles: trapezius, splenius, and semispinalis. For the ultrasonographic study, a convex transducer was placed transversely over C3-C4 after the insertion of the needle into the muscle. The results of both the cadaveric and ultrasonic studies found that the needle does pierce the cervical multifidus muscle during insertion and that the tip of the needle rests properly against the vertebral laminae, thereby guarding the sensitive underlying spinal structures from damage. This anatomical and ultrasound imaging study supports that dry needling of the cervical multifidus could be conducted clinically. Copyright © 2017. Published by Elsevier Inc.
3-D ultrasound guidance of surgical robotics: a feasibility study.
Pua, Eric C; Fronheiser, Matthew P; Noble, Joanna R; Light, Edward D; Wolf, Patrick D; von Allmen, Daniel; Smith, Stephen W
2006-11-01
Laparoscopic ultrasound has seen increased use as a surgical aide in general, gynecological, and urological procedures. The application of real-time, three-dimensional (RT3D) ultrasound to these laparoscopic procedures may increase information available to the surgeon and serve as an additional intraoperative guidance tool. The integration of RT3D with recent advances in robotic surgery also can increase automation and ease of use. In this study, a 1-cm diameter probe for RT3D has been used laparoscopically for in vivo imaging of a canine. The probe, which operates at 5 MHz, was used to image the spleen, liver, and gall bladder as well as to guide surgical instruments. Furthermore, the three-dimensional (3-D) measurement system of the volumetric scanner used with this probe was tested as a guidance mechanism for a robotic linear motion system in order to simulate the feasibility of RT3D/robotic surgery integration. Using images acquired with the 3-D laparoscopic ultrasound device, coordinates were acquired by the scanner and used to direct a robotically controlled needle toward desired in vitro targets as well as targets in a post-mortem canine. The rms error for these measurements was 1.34 mm using optical alignment and 0.76 mm using ultrasound alignment.
NASA Astrophysics Data System (ADS)
Erpelding, Todd N.; Kim, Chulhong; Pramanik, Manojit; Guo, Zijian; Dean, John; Jankovic, Ladislav; Maslov, Konstantin; Wang, Lihong V.
2010-02-01
Sentinel lymph node biopsy (SLNB) has become the standard method for axillary staging in breast cancer patients, relying on invasive identification of sentinel lymph nodes (SLNs) following injection of blue dye and radioactive tracers. While SLNB achieves a low false negative rate (5-10%), it is an invasive procedure requiring ionizing radiation. As an alternative to SLNB, ultrasound-guided fine needle aspiration biopsy has been tested clinically. However, ultrasound alone is unable to accurately identify which lymph nodes are sentinel. Therefore, a non-ionizing and noninvasive detection method for accurate SLN mapping is needed. In this study, we successfully imaged methylene blue dye accumulation in vivo in rat axillary lymph nodes using a Phillips iU22 ultrasound imaging system adapted for photoacoustic imaging with an Nd:YAG pumped, tunable dye laser. Photoacoustic images of rat SLNs clearly identify methylene blue dye accumulation within minutes following intradermal dye injection and co-registered photoacoustic/ultrasound images illustrate lymph node position relative to surrounding anatomy. To investigate clinical translation, the imaging depth was extended up to 2.5 cm by adding chicken breast tissue on top of the rat skin surface. These results raise confidence that photoacoustic imaging can be used clinically for accurate, noninvasive SLN mapping.
Chang, Yun Hee; Oh, Tae Hoon; Lee, Jae Whan; Park, Seung Chol; Seo, Ill Young; Jeong, Hee Jong; Kwon, Whi-An
2015-01-01
To determine whether listening to music during transrectal ultrasound (TRUS)-guided 12-core needle prostate biopsy decreases anxiety, pain and dissatisfaction among patients and results in a more comfortable and better tolerated procedure. 76 male patients who underwent TRUS-guided prostate biopsy between March 2013 and June 2014 were randomized into the following groups: no music (group I, n = 38) or classical music (group II, n = 38) during the procedure. Before TRUS-guided prostate biopsy, lidocaine gel was instilled into the rectum. Patient anxiety levels were quantified using the State-Trait Anxiety Inventory. A visual analog scale (0-10) was used for self-assessment of satisfaction, discomfort and willingness among patients to have a repeat TRUS-guided prostate biopsy. Demographic characteristics, mean age, procedure duration and procedure indications did not differ statistically between the two groups. The mean anxiety level and mean pain score of group II were significantly lower than those of group I (p = 0.001 and p = 0.003, respectively). Group II also had a significantly higher mean satisfaction score than group I (p = 0.007). Before the procedure, heart rate and systolic blood pressure were similar in groups I and II; however, after the procedure, levels were lower in group II than in group I (heart rate, p = 0.014; systolic blood pressure, p = 0.011). Listening to music during TRUS-guided prostate biopsy significantly reduced patients' feelings of pain, discomfort and dissatisfaction. Music can serve as a simple, inexpensive and effective adjunct to sedation during TRUS-guided prostate biopsy. We recommend playing music during TRUS-guided prostate biopsy. 2014 S. Karger AG, Basel
Ethnicity influences pain after ultrasound-guided percutaneous liver biopsy.
Mahadeva, Sanjiv; Mahfudz, Anis S; Vijayananthan, Anushya
2015-12-01
The influence of ethnicity on pain complicating ultrasound-guided percutaneous liver biopsy (US-guided PLB) and its clinical impact has not been reported to date. Consecutive adults from a multiethnic background, undergoing an US-guided PLB, were independently assessed for pain up to 6 h after the procedure. Clinical and demographic parameters were analysed to determine independent predictors of significant pain after PLB. Willingness to undergo a repeat procedure was assessed 1 week after PLB. Data from 203 patients (median age 50 years; 43.9% female; ethnicity: Malay 41.5%, Chinese 40%, Indian 18%; median BMI 27.7 kg/m; median waist circumference 92.0 cm) were analysed. Pain after US-guided PLB was experienced in 133 (61.1%) patients, with severity grades as follows: none, n=81 (39.9%); mild, n=56 (27.6%); moderate, n=51 (25.1%); and severe, n=15 (7.4%). Analgesia requirements correlated well with severity of pain. Independent predictors of significant pain after PLB (moderate and severe categories) in patients included age less than 50 years [odds ratio (OR) 3.0], female sex (OR 3.7), Indian ethnicity (OR 2.9) and Malay ethnicity (OR 2.7), but not number of needle passes, BMI and educational levels. Patients who experienced moderate/severe pain were less willing to undergo a repeat PLB compared with those who experienced mild/no pain (60.9 vs. 82.8%, P=0.001). Ethnicity has an important role in the development of pain after US-guided PLB. This has a significant impact on willingness to repeat the procedure.