Sample records for ultrasound-guided transverse abdominis

  1. Postoperative analgesic efficacy of ultrasound-guided ilioinguinal-iliohypogastric nerve block compared with medial transverse abdominis plane block in inguinal hernia repair: A prospective, randomised trial.

    PubMed

    Bhatia, Nidhi; Sen, Indu Mohini; Mandal, Banashree; Batra, Ankita

    2018-03-29

    Analgesic efficacy of ultrasound-guided transverse abdominis plane block, administered a little more medially, just close to the origin of the transverse abdominis muscle has not yet been investigated in patients undergoing unilateral inguinal hernia repair. We hypothesised that medial transverse abdominis plane block would provide comparable postoperative analgesia to ilioinguinal-iliohypogastric nerve block in inguinal hernia repair patients. This prospective, randomised trial was conducted in 50 ASA I and II male patients≥18 years of age. Patients were randomised into two groups to receive either pre-incisional ipsilateral ultrasound-guided ilioinguinal-iliohypogastric nerve block or medial transverse abdominis plane block, with 0.3ml/kg of 0.25% bupivacaine. Our primary objective was postoperative 24-hour analgesic consumption and secondary outcomes included pain scores, time to first request for rescue analgesic and side effects, if any, in the postoperative period. There was no significant difference in the total postoperative analgesic consumption [group I: 66.04mg; group II: 68.33mg (P value 0.908)]. Time to first request for rescue analgesic was delayed, though statistically non-significant (P value 0.326), following medial transverse abdominis plane block, with excellent pain relief seen in 58.3% patients as opposed to 45.8% patients in ilioinguinal-iliohypogastric nerve block group. Medial transverse abdominis plane block being a novel, simple and easily performed procedure can serve as an useful alternative to ilioinguinal-iliohypogastric nerve block for providing postoperative pain relief in inguinal hernia repair patients. Copyright © 2018 Société française d'anesthésie et de réanimation (Sfar). Published by Elsevier Masson SAS. All rights reserved.

  2. Measurement of superficial and deep abdominal muscle thickness: an ultrasonography study.

    PubMed

    Tahan, Nahid; Khademi-Kalantari, Khosro; Mohseni-Bandpei, Mohammad Ali; Mikaili, Saeed; Baghban, Alireza Akbarzadeh; Jaberzadeh, Shapour

    2016-08-23

    Real-time ultrasound imaging is a valid method in the field of rehabilitation. The ultrasound imaging allows direct visualization for real-time study of the muscles as they contract over the time. Measuring of the size of each abdominal muscle in relation to the others provides useful information about the differences in structure, as well as data on trunk muscle activation patterns. The purpose of this study was to assess the size and symmetry of the abdominal muscles at rest in healthy adults and to provide a reference range of absolute abdominal muscle size in a relatively large population. A total 156 healthy subjects with the age range of 18-44 years were randomly recruited. The thickness of internal oblique, external oblique, transverse abdominis, and rectus abdominis muscles was measured at rest on both right and left sides using ultrasound. Independent t test was used to compare the mean thickness of each abdominal muscle between males and females. Differences on side-to-side thicknesses were assessed using paired t test. The association between abdominal muscle thicknesses with gender and anthropometric variables was examined using the Pearson correlation coefficient. A normal pattern of increasing order of mean abdominal muscle thickness was found in both genders at both right and left sides: transverse abdominis < external oblique < internal oblique < rectus abdominis. There was a significant difference on the size of transverse abdominis, internal oblique, and external oblique muscles between right and left sides in both genders. Males had significantly thicker abdominal muscles than females. Age was significantly correlated with the thickness of internal oblique, external oblique, and rectus abdominis muscles. Body mass index was also positively correlated with muscle thickness of rectus abdominis and external oblique. The results provide a normal reference range for the abdominal muscles in healthy subjects and may be used as an index to find out abnormalities and also to evaluate the effectiveness of different interventions.

  3. Analgesic effects of ultrasound-guided transverse abdominis plane block using different volumes and concentrations of local analgesics after laparoscopic cholecystectomy.

    PubMed

    Şahin, Ayça Sultan; Ay, Necmiye; Şahbaz, Nuri Alper; Akay, Mehlika Kocabaş; Demiraran, Yavuz; Derbent, Abdurrahim

    2017-02-01

    Objective To evaluate the effects of an ultrasound-guided transverse abdominis plane (US-TAP) block used for postoperative pain relief by comparing the efficacy of two different volumes/concentrations of the local anaesthetic bupivacaine in patients undergoing laparoscopic cholecystectomies. Methods This randomized study enrolled patients undergoing laparoscopic cholecystectomies. They were randomized to two groups: group A received a 20 ml US-TAP block (50 mg bupivacaine +10 ml saline solution) and group B received a 30 ml US-TAP block (50 mg bupivacaine + 20 ml saline solution). The intraoperative consumption of remifentanil, the requirement for postoperative rescue analgesics, patient satisfaction scores, postoperative complications, and postoperative pain as measured by a visual analogue scale at 20 min, 12 h, and 24 h were recorded. Results A total of 60 patients enrolled in the study. There were no differences between the two groups with respect to demographic characteristics, duration of anaesthesia and patient satisfaction scores. The intraoperative consumption of remifentanil, postoperative VAS scores (20 min, 12 h and 24 h) and the requirement for postoperative analgesics were all significantly lower in group B who received a larger volume but a lower concentration of local anaesthetic solution compared with group A. Conclusion A US-TAP block can form part of a balanced postoperative analgesic regimen following laparoscopic cholecystectomy.

  4. Ultrasound Assessment of the Transverse Abdominis During Functional Movement.

    PubMed

    Mangum, L Colby; Henderson, Kaitlin; Murray, Kyle P; Saliba, Susan A

    2018-05-01

    The traditional activation ratio divides contracted muscle thickness by resting muscle thickness while an abdominal draw-in maneuver is performed during hook lying. Ultrasound imaging during function, such as standing or gait, or peak knee flexion in a single-leg squat allows for further visualization of muscle activity. The goal of this study was to examine activation ratio calculations for transverse abdominis function in supine versus loaded conditions to determine the most informative normalization strategy for muscle activity based on thickness values. Transverse abdominis thickness was measured via ultrasound in 35 healthy participants under 4 different conditions. Comparisons were made between the traditional activation ratio tabletop, standing activation ratio (standing abdominal draw-in maneuver thickness/quiet standing thickness), and functional activation ratio (single-leg squat thickness/quiet standing thickness). Additionally, a cued activation ratio (single-leg squat with cued abdominal draw-in maneuver thickness/single-leg squat thickness) during the single-leg squat was obtained. Activation ratios of greater than 1.0 indicated that participants could activate the muscle during activity, and values were compared by analysis of variance. The participants included 23 women and 12 men with a mean age ± SD of 21.3 ± 2.7 years, mass of 66.1 ± 14.4 kg, and height of 168.5 ± 10.1 cm. Activation ratios exceeded 1.0 in 94.3% for the traditional activation ratio, 85.7% for the standing activation ratio, 82.9% for the cued activation ratio, and 82.9% for the functional activation ratio. With groups defined as tabletop activated or not, the standing, cued, and functional activation ratios were all significantly different (all P < .05). Normalizing muscle thickness to the corresponding functional position quiet value provides a useful functional activation ratio and may help clinicians better understand the transverse abdominis role during complex functional tasks. Assessment techniques using various formulas for activation ratios reveal that the muscle functions differently during weight bearing compared to traditional measures. © 2017 by the American Institute of Ultrasound in Medicine.

  5. Comparison of ultrasound-guided posterior transversus abdominis plane block and lateral transversus abdominis plane block for postoperative pain management in patients undergoing cesarean section: a randomized double-blind clinical trial study.

    PubMed

    Faiz, Seyed Hamid Reza; Alebouyeh, Mahmoud Reza; Derakhshan, Pooya; Imani, Farnad; Rahimzadeh, Poupak; Ghaderi Ashtiani, Maryam

    2018-01-01

    Due to the importance of pain control after abdominal surgery, several methods such as transversus abdominis plane (TAP) block are used to reduce the pain after surgery. TAP blocks can be performed using various ultrasound-guided approaches. Two important approaches to do this are ultrasound-guided lateral and posterior approaches. This study aimed to compare the two approaches of ultrasound-guided lateral and posterior TAP blocks to control pain after cesarean section. In this double-blind clinical trial study, 76 patients scheduled for elective cesarean section were selected and randomly divided into two groups of 38 and underwent spinal anesthesia. For pain management after the surgery, one group underwent lateral TAP block and the other group underwent posterior TAP block using 20cc of ropivacaine 0.2% on both sides. Pain intensity was evaluated based on Numerical Analog Scale (NAS) at rest and when coughing, 2, 4, 6, 12, 24 and 36 hours after surgery. The pain at rest in the posterior group at all hours post surgery was lower than the lateral group, especially at 6, 12 and 24 hours after the surgery and the difference was statistically significant ( p =0.03, p <0.004, p =0.001). The results of this study show that ultrasound-guided posterior TAP block compared with the lateral TAP block was more effective in pain control after cesarean section.

  6. Analgesic effect of ultrasound-guided transversus abdominis plane block after total abdominal hysterectomy: a randomized, double-blind, placebo-controlled trial.

    PubMed

    Røjskjaer, Jesper O; Gade, Erik; Kiel, Louise B; Lind, Morten N; Pedersen, Lars M; Kristensen, Billy B; Rasmussen, Yvonne H; Foss, Nicolai B

    2015-03-01

    To assess the effect of bilateral ultrasound-guided transversus abdominis plane block with ropivacaine compared with placebo as part of a multimodal analgesic regimen. A randomized, double-blind, placebo-controlled trial following the CONSORT criteria. Hvidovre University Hospital. Forty-six women scheduled for total abdominal hysterectomy. Women received either ropivacaine 0.75%, 20 mL (n = 24) or 0.9% saline, 20 mL (n = 24) in the transversus abdominis plane on each side. Primary outcome was the 24-h postoperative morphine consumption. Secondary outcomes were pain scores at rest and during coughing, postoperative nausea and vomiting at 1, 2, 4, 6, 8, and 24 h, and time to first mobilization. There was no difference in the mean 24-h postoperative morphine consumption between the two groups (p = 0.733). The ropivacaine group had significantly lower median pain scores at 1 h (p = 0.008) and 2 h (p = 0.027) postoperatively at rest and at 8 h (p = 0.028) during coughing. There was no significant difference in other secondary outcomes. There was no reduction in 24-h morphine consumption when using an ultrasound-guided transversus abdominis plane block in women undergoing total abdominal hysterectomy. As part of a multimodal regimen the transversus abdominis plane block showed some effect on pain scores at rest only in the early postoperative period. © 2014 Nordic Federation of Societies of Obstetrics and Gynecology.

  7. Analgesic efficacy of transversus abdominis plane block in neonates and early infants for colostomy and reversal of colostomy.

    PubMed

    Chen, Chee Kean; Teo, Shu Ching; Phui, Vui Eng; Saman, Mat Ariffin

    2015-01-01

    The application of ultrasound-guided transversus abdominis plane (TAP) block in paediatric population is gaining popularity among anaesthetists. We present a case series of ultrasound-guided TAP block in ten neonate and infants undergoing colostomy and reversal of stoma. Classical TAP as described by Hebbard was carried out and a maximum dosage of 1ml/kg of 0.25% levobupivacaine was injected. Pain score was assessed using Neonatal Infant Pain Scale for 24 hours. In all patients, the block was successful with minimal hemodynamic changes intraoperatively and no additional systemic analgesia was needed intraoperative and immediate postoperatively. Ultrasound-guided TAP block has an important role in providing safe and effective analgesia for colostomy creation and reversal of stoma surgeries in paediatric population.

  8. Ultrasound guided transversus abdominis plane vs surgeon administered intraoperative regional field infiltration with bupivacaine for early postoperative pain control in children undergoing open pyeloplasty.

    PubMed

    Lorenzo, Armando J; Lynch, Johanne; Matava, Clyde; El-Beheiry, Hossam; Hayes, Jason

    2014-07-01

    Regional analgesic techniques are commonly used in pediatric urology. Ultrasound guided transversus abdominis plane block has recently gained popularity. However, there is a paucity of information supporting a benefit over regional field infiltration. We present a parallel group, randomized, controlled trial evaluating ultrasound guided transversus abdominis plane block superiority over surgeon delivered regional field infiltration for children undergoing open pyeloplasty at a tertiary referral center. Following ethics board approval and registration, children 0 to 6 years old were recruited and randomized to undergo perioperative transversus abdominis plane block or regional field infiltration for early post-pyeloplasty pain control. General anesthetic delivery, surgical technique and postoperative analgesics were standardized. A blinded assessor regularly captured pain scores in the recovery room using the FLACC (Face, Legs, Activity, Cry, Consolability) scale. The primary outcome was the need for rescue morphine administration based on a FLACC score of 3 or higher. Two pediatric urologists performed 57 pyeloplasties during a 2.5-year period, enrolling 32 children (16 in each group, balanced for age and weight). There were statistically significant differences in the number of children requiring rescue morphine administration (13 of 16 receiving transversus abdominis plane block and 6 of 16 receiving regional field infiltration, p = 0.011), mean ± SD total morphine consumption (0.066 ± 0.051 vs 0.028 ± 0.040 mg/kg, p = 0.021) and mean ± SD pain scores (5 ± 5 vs 2 ± 3, p = 0.043) in the recovery room, in favor of surgeon administered regional field infiltration. No local anesthetic specific adverse events were noted. Ultrasound guided transversus abdominis plane block is not superior to regional field infiltration with bupivacaine as a strategy to minimize early opioid requirements following open pyeloplasty in children. Instead, our data suggest that surgeon delivered regional field infiltration provides better pain control. Copyright © 2014 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  9. A randomised trial of the analgesic efficacy of ultrasound-guided transversus abdominis plane block after caesarean delivery under general anaesthesia.

    PubMed

    Tan, Terry T; Teoh, Wendy H L; Woo, David C M; Ocampo, Cecilia E; Shah, Mukesh K; Sia, Alex T H

    2012-02-01

    Previous studies examining the efficacy of transversus abdominis plane block after caesarean section have mostly been in parturients under spinal anaesthesia. We postulated that the advantage of performing transversus abdominis plane block after caesarean section might be even more obvious after general anaesthesia, resulting in reduced 24-h consumption of morphine. DESIGN, SETTING, PATIENTS AND INTERVENTIONS: In this single centre, randomised double-blind controlled trial, 40 women who underwent caesarean delivery under general anaesthesia were allocated randomly to receive a transversus abdominis plane block or no block. In those who received the block, 20 ml of levobupivacaine 2.5 mg ml was deposited bilaterally into the transversus abdominis plane under ultrasound guidance using a Sonosite Titan (SonoSite, Bothell, Washington, USA) 7-13 MHz linear transducer at the end of surgery when the patient was still anaesthetised. We recorded patient-controlled intravenous morphine use for 24 h, pain scores at rest and activity, sedation, nausea and vomiting, use of antiemetic medication and overall maternal satisfaction. The primary outcome was 24-h morphine consumption. Patients who received the transversus abdominis plane block used significantly less morphine in 24 h than those in the control group [12.3 (2.6) vs. 31.4 mg (3.1), P<0.001) and had higher satisfaction scores [16 (80%) vs. 5 (25%), P = 0.012). There were no differences between groups in the visual analogue pain scores, sedation level, nausea and vomiting or the use of antiemetic medication. Ultrasound-guided transversus abdominis plane block reduced morphine consumption following caesarean section under general anaesthesia, with increased maternal satisfaction.

  10. Comparison of ultrasound guided transversus abdominis plane block versus local wound infiltration for post operative analgesia in patients undergoing gynaecological surgery under general anaesthesia.

    PubMed

    Ranjit, S; Shrestha, S K

    2014-01-01

    Transversus abdominis plane block has been recently developed as a part of multimodal post operative analgesic techniques. We compared the analgesic efficacy of this technique with local bupivacaine infiltration in patients undergoing gynaecological surgeries with pfannenstiel incision and lower midline incision under general anaesthesia. To evaluate the efficacy of ultrasound guided transversus abdominis plane block for postoperative analgesia. Patients were randomly allocated to three groups: control group (n=15), transversus abdominis plane block group (n=15), who received bilateral transversus abdominis plane blockwith 0.25% bupivacaine, and local infiltration group (n=15), who received local wound infiltration with 0.25% bupivacaine at the end of surgery. All patients received intramuscular diclofenac 12 hourly and intravenous tramadol SOS in the postoperative period. Visual analogue scores for pain were assessed at 1,2,4,8,12 and 24 hours postoperatively and these were compared between the three groups. Average tramadol consumption in 24 hours were also compared among the three groups. Data were subjected to univariate ANOVA test and chi-square test. Level of significance was set at 0.05. Visual analogue scores were significantly less in transversus abdominis plane block group and effect lasted up to 12 hours at rest postoperatively and 8 hours during cough and movement. Bilateral Transversus abdominis plane block was effective in reducing postoperative pain scores for 8 to 12 hours postoperatively. This block was also successful in reducing postoperative opioid requirement.

  11. The importance of a normal breathing pattern for an effective abdominal-hollowing maneuver in healthy people: an experimental study.

    PubMed

    Ha, Sung-min; Kwon, Oh-yun; Kim, Su-jung; Choung, Sung-dae

    2014-02-01

    A normal breathing pattern while performing the abdominal-hollowing (AH) maneuver or spinal-stabilization exercise is essential for the success of rehabilitation programs and exercises. In previous studies, subjects were given standardized instructions to control the influence of respiration during the AH maneuver. However, the effect of breathing pattern on abdominal-muscle thickness during the AH maneuver has not been investigated. To compare abdominal-muscle thickness in subjects performing the AH maneuver under normal and abnormal breathing-pattern conditions and to investigate the effect of breathing pattern on the preferential contraction ratio (PCR) of the transverse abdominis. Comparative, repeated-measures experimental study. University research laboratory. 16 healthy subjects (8 male, 8 female) from a university population. A real-time ultrasound scanner was used to measure abdominal-muscle thickness during normal and abnormal breathing patterns. A paired t test was used to assess the effect of breathing pattern on abdominal-muscle thickness and PCR. Muscle thickness in the transverse abdominis and internal oblique muscles was significantly greater under the normal breathing pattern than under the abnormal pattern (P < .05). The PCR of the transverse abdominis was significantly higher under the normal breathing pattern compared with the abnormal pattern (P < .05). The results indicate that a normal breathing pattern is essential for performance of an effective AH maneuver. Thus, clinicians should ensure that patients adopt a normal breathing pattern before performing the AH maneuver and monitor transverse abdominis activation during the maneuver.

  12. The effect of morphine added to bupivacaine in ultrasound guided transversus abdominis plane (TAP) block for postoperative analgesia following lower abdominal cancer surgery, a randomized controlled study.

    PubMed

    El Sherif, Fatma Adel; Mohamed, Sahar Abdel-Baky; Kamal, Shereen Mamdouh

    2017-06-01

    Transversus abdominis plane (TAP) block used for management of surgical abdominal pain by injecting local anesthetics into the plane between the internal oblique and transversus abdominis muscles. We aimed to explore the effect of adding morphine to bupivacaine in ultrasound guided TAP-block in patients undergoing lower abdominal cancer surgery. Randomized, double-blind, prospective study. Clinical trial identifier: NCT02566096. Academic medical center. Sixty patients were enrolled in this study after ethical committee approval. Patients divided into 2 groups (30 each): Bupivacaine group (GB): given ultrasound guided TAP-block 20ml 0.5% bupivacaine diluted in 20ml saline; Morphine group (GM): given ultrasound guided TAP-block with 20ml 0.5% bupivacaine+10mg morphine sulphate diluted in 20ml saline. Patients were observed for total morphine consumption, time for first request of rescue analgesia, sedation scores, hemodynamics and side effects for 24h postoperatively. Morphine added to bupivacaine in TAP block compared to bupivacaine alone reduced total morphine consumption (5.33±1.28mg) (10.70±3.09mg) respectively (p<0.001), prolonged the time to first request of analgesia (10.40±4.96h) (6.97±3.26h) respectively (p<0.008), with a statistically significant decrease in (VAS-M) in GM compared with GB at 12h postoperatively (p<0.002). No significant differences in hemodynamics, respiratory rate, oxygen saturation, sedation score, and side effects except for nausea were observed (p>0.05). Addition of morphine to bupivacaine in TAP block is effective method for pain management in patients undergoing major abdominal cancer surgery without serious side effects. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Relative Efficacy of Ultrasound-guided Ilioinguinal-iliohypogastric Nerve Block versus Transverse Abdominis Plane Block for Postoperative Analgesia following Lower Segment Cesarean Section: A Prospective, Randomized Observer-blinded Trial.

    PubMed

    Kiran, L Vamsee; Sivashanmugam, T; Kumar, V R Hemanth; Krishnaveni, N; Parthasarathy, S

    2017-01-01

    Quality of postoperative analgesia after cesarean section makes difference to mother in child bonding, early ambulation, and discharge. Ilioinguinal iliohypogastric (ILIH) and transverse abdominis plane (TAP) block had been tried to reduce the opioid analgesics, but the relative efficacy is unknown. Hence, this study was designed to compare the efficacy of these two regional analgesic techniques in sparing postoperative rescue analgesic requirement following lower segment cesarean section (LSCS). Sixty patients who underwent LSCS were randomly allocated into two groups to receive either US-guided TAP block or ILIH nerve block using sealed envelope technique at the end of the surgery. In the postoperative ward, whenever patient complained of pain, pain nurse in-charge administered the rescue analgesics as per the study protocol. A blinded observer visited the patient at 0, 2, 4, 6, 8, 10, 12, and 24 h postoperative intervals and recorded the quality of pain relief and the amount of rescue analgesic consumed. All patients in both the study groups required one dose of rescue analgesics in the form of injection diclofenac sodium 50 mg intravenously but subsequently 57% of patients did not require any further analgesics till 24 h in the TAP block group whereas in ILIH group, only 13% did not require further analgesics ( P = 0.00), correspondingly the cumulative tramadol dose was significantly higher at all the time interval in the ILIH group when compared to the TAP group. Quality of postoperative analgesia provided by TAP block was superior to ILIH block following LSCS.

  14. Subcostal Transverse Abdominis Plane Block for Acute Pain Management: A Review.

    PubMed

    Soliz, Jose M; Lipski, Ian; Hancher-Hodges, Shannon; Speer, Barbra Bryce; Popat, Keyuri

    2017-10-01

    The subcostal transverse abdominis plane (SCTAP) block is the deposition of local anesthetic in the transverse abdominis plane inferior and parallel to the costal margin. There is a growing consensus that the SCTAP block provides better analgesia for upper abdominal incisions than the traditional transverse abdominis plane block. In addition, when used as part of a four-quadrant transverse abdominis plane block, the SCTAP block may provide adequate analgesia for major abdominal surgery. The purpose of this review is to discuss the SCTAP block, including its indications, technique, local anesthetic solutions, and outcomes.

  15. Pharmacokinetics of bupivacaine after bilateral ultrasound-guided transversus abdominis plane block following cesarean delivery under spinal anesthesia.

    PubMed

    Trabelsi, B; Charfi, R; Bennasr, L; Marzouk, S Ben; Eljebari, H; Jebabli, N; Sassi, M Ben; Trabelsi, S; Maghrebi, H

    2017-11-01

    Transversus abdominis plane block is an effective method of post-cesarean analgesia. There are no data available about plasma bupivacaine levels after this block in adults. This study aimed to assess bupivacaine pharmacokinetic parameters after ultrasound-guided transversus abdominis plane blocks following cesarean delivery under spinal anesthesia. A prospective observational study in parturients undergoing elective cesarean delivery under hyperbaric bupivacaine spinal anesthesia was conducted. After surgery, patients received bilateral transversus abdominis plane block (50mg bupivacaine each side). Venous blood samples were collected immediately before performing the block and at 10, 20, 30, 45, 60, 90, 120, 180, 240, 720 and 1440minutes. High performance liquid chromatography was used to measure total plasma bupivacaine concentrations. Mean bupivacaine area under the curve (AUC) was calculated from 0 to 24hours. Data were collected from 17 parturients. Mean age and body mass index were 31±6y and 30±4kg/m 2 respectively. Mean plasma bupivacaine concentration before the block was 171ng/mL. Mean peak concentration was 802.36ng/mL (range 231.8 to 3504.5ng/mL). Mean time to peak concentration was 30min and mean area-under-the-curve (0-24h) was 4505.4h.ng/mL. Mean elimination half-life was 8.75h. Three subjects had concentrations above the quoted toxic threshold and mild symptoms suggestive of neurotoxicity were reported by two subjects, but no treatment was required. Single-dose bilateral transversus abdominis plane block using 100mg of bupivacaine, after spinal anesthesia for cesarean delivery, can result in toxic plasma bupivacaine concentrations. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. No benefit of ultrasound-guided transversus abdominis plane blocks over wound infiltration with local anaesthetic in elective laparoscopic colonic surgery: results of a double-blind randomized controlled trial.

    PubMed

    Rashid, A; Gorissen, K J; Ris, F; Gosselink, M P; Shorthouse, J R; Smith, A D; Pandit, J J; Lindsey, I; Crabtree, N A

    2017-07-01

    Advances in laparoscopic techniques combined with enhanced recovery pathways have led to faster recuperation and discharge after colorectal surgery. Peripheral nerve blockade using transversus abdominis plane (TAP) blocks reduce opioid requirements and provide better analgesia for laparoscopic colectomies than do inactive controls. This double-blind randomized study was performed to compare TAP blocks using bupivacaine with standardized wound infiltration with local anaesthetic (LA). Seventy-one patients were randomized to receive either TAP block or wound infiltration. The TAP blocks were performed by experienced anaesthetists who used ultrasound guidance to deliver 40 ml of 0.25% bupivacaine post-induction into the transverse abdominis plane. In the control group, 40 ml of 0.25% bupivacaine was injected around the trocar and the extraction site by the surgeon. Both groups received patient-controlled analgesia (PCA) with intravenous morphine. Patients and nursing staff assessed pain scores 6, 12, 24 and 48 h after surgery. The primary outcome was overall morphine use in the first 48 h. Of the 71 patients, 20 underwent a right hemicolectomy and 51 a high anterior resection. The modified intention-to-treat analysis showed no significant differences in overall morphine use [47.3 (36.2-58.5) mg vs 46.7 (36.2-57.3) mg; mean (95% CI), P = 0.8663] in the first 48 h. Pain scores were similar at 6, 12, 24 and 48 h. No differences were found regarding time to mobilization, resumption of diet and length of hospital stay. In elective laparoscopic colectomies, standardized wound infiltration with LA has the same analgesic effect as TAP blocks post-induction using bupivacaine at 48 h. Colorectal Disease © 2016 The Association of Coloproctology of Great Britain and Ireland.

  17. Effectiveness of ultrasound-guided transversus abdominis plane block and rectus sheath block in pain control and recovery after gynecological transumbilical single-incision laparoscopic surgery.

    PubMed

    Mugita, M; Kawahara, R; Tamai, Y; Yamasaki, K; Okuno, S; Hanada, R; Inaoka, M; Funato, T

    2014-01-01

    To evaluate the effectiveness of ultrasound-guided transversus abdominis plane (TAP) and rectus sheath (RS) blocks in pain management and recovery after gynecological single-incision laparoscopic surgery (SILS). Abilateral TAP block (Group A, n = 9), bilateral TAP and RS blocks (Group B, n = 10), and a bilateral RS block (Group C, n = 9) with 40 ml ropivacaine per patient were conducted in 28 patients undergoing SILS for ovarian tumors. A pain score and walking distance in a 6-minute walk test (6MWT) were examined. Pain scores were significantly lower on postoperative day (POD) 3 than on POD 1 in Groups B (p = 0.03) and C (p = 0.02). The walking distance on POD 3 was comparable with that before surgery in Group C (p = 0.75), but shorter in Groups A (p = 0.004) and B (p = 0.02). The RS block alone was the most effective in relieving pain and accelerating general recovery after gynecological SILS.

  18. [Ultrasound-guided Rectus Sheath Block vs Transversus Abdominis Plane Block in Children Undergoing Umbilical Hernia Repair].

    PubMed

    Torii, Naoko; Tachibana, Kazuya; Iwasaki, Mitsuo; Takeuchi, Muneyuki; Kinouchi, Keiko

    2016-06-01

    Although many reports describe the usefulness of the rectus sheath block (RSB) in the umbilical hernia repair, the efficacy of the transversus abdominis plane block (TAPB) is rarely reported. The purpose of this study was to compare the efficacy and technique of ultrasound-guided RSB and TAPB in children undergoing umbilical hernia repair. Thirty-four children younger than 12 years of age scheduled for umbilical hernia repair were enrolled in this prospective observer-blinded randomized clinical trial. They were randomly assigned either to RSB group (median age, 3.7 years) or TAPB group (median age, 3.8 years). After the induction of general anesthesia with sevoflurane, nitrous oxide, and oxygen children in both groups received regional anesthesia with 0.3 ml x kg(-1) of 0.25% ropivacaine on each side under ultrasound guidance. Hemodynamic changes at the skin incision, postoperative pain scores and parental satisfaction were recorded. Anesthesiologists rated the quality of ultrasound images and easiness of the block performance. The patients' demographics of the two groups were similar. There were no significant differences in the time needed for the block procedure, quality of ultrasound images and the change of the heart rate and blood pressure at the skin incision between the two groups. Postoperative pain score (immediately, 2 and 4 hours after the operation), need for rescue analgesia and satisfaction of the parents also did not differ. There were no major complications in the patients. TAPB provided comparable perioperative analgesia and easiness of block performance to RSB in the pediatric umbilical hernia repair.

  19. Postoperative analgesic efficacy of single-shot and continuous transversus abdominis plane block after laparoscopic cholecystectomy: A randomized controlled clinical trial.

    PubMed

    Choi, Yun-Mi; Byeon, Gyeong-Jo; Park, Soon-Ji; Ok, Young-Min; Shin, Sang-Wook; Yang, Kwangho

    2017-06-01

    To compare the analgesic efficacy of ultrasound-guided single-shot and continuous transversus abdominis plane (TAP) block to that of IV-PCA in patients undergoing laparoscopic cholecystectomy. Prospective randomized controlled trial. Post-anesthesia care unit and General ward. 108 American Society of Anesthesiologist (ASA) physical status I-II patients undergoing laparoscopic cholecystectomy. Group A received IV-PCA; group B received both ultrasound-guided single-shot TAP block with 0.2% ropivacaine (20mL) and IV-PCA; and group C received continuous TAP block using an ultrasound-guidance-inserted indwelling catheter. In group C, infusion of 0.2% ropivacaine at a basal rate of 3mL/h, bolus dose of 4mL, and a lockout interval of 30min was maintained for 48h postoperatively. The primary outcome was evaluated analgesic efficacy using the numeric rating scale (NRS) for 48h postoperatively. Other outcomes included the number of patients requiring additional analgesics, patient satisfaction with postoperative pain control, and incidence of postoperative adverse events. Compared to other groups, group C had higher deep abdominal NRS at 1h postoperatively (P<0.05), and lower incidence of postoperative urinary retention (P<0.05). There were no significant intergroup differences in the number of patients requiring additional analgesics, and patient satisfaction with postoperative pain control. Compared to IV-PCA with or without single-shot TAP block, ultrasound-guided continuous TAP block provided similar analgesia in somatic pain and less analgesia in visceral pain. Moreover, the latter resulted in a lower incidence of postoperative urinary retention. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Successful treatment of athletic pubalgia in a lacrosse player with ultrasound-guided needle tenotomy and platelet-rich plasma injection: a case report.

    PubMed

    Scholten, Paul M; Massimi, Stephen; Dahmen, Nick; Diamond, Joanne; Wyss, James

    2015-01-01

    Athletic pubalgia is a syndrome of persistent groin pain due to chronic repetitive trauma or stress involving the pelvic joints and many musculotendinous structures that cross the anterior pelvis. As a result, the differential diagnosis can be complex, but insertional tendinopathies are the most common. This case report describes a novel approach to the treatment of distal rectus abdominis tendinopathies with ultrasound-guided needle tenotomy and platelet-rich plasma (PRP) injection. After injection, the patient returned to pain-free play at his previous level of intensity. This suggests that PRP may be a useful treatment for this diagnosis. Copyright © 2015. Published by Elsevier Inc.

  1. Ultrasound-guided transversus abdominis plane block in patients undergoing open inguinal hernia repair: 0.125% bupivacaine provides similar analgesic effect compared to 0.25% bupivacaine.

    PubMed

    Erdoğan Arı, Dilek; Yıldırım Ar, Arzu; Karadoğan, Firdevs; Özcabı, Yetkin; Koçoğlu, Ayşegül; Kılıç, Fatih; Akgün, Fatma Nur

    2016-02-01

    To evaluate the effectiveness of 0.125% bupivacaine compared to 0.25% bupivacaine for ultrasound-guided transversus abdominis plane (TAP) block in patients undergoing open inguinal hernia repair. Randomized, double-blind study. Educational and research hospital. Forty adult patients of American Society of Anesthesiologists physical status I-III undergoing elective primary unilateral open inguinal hernia repair under spinal anesthesia. Patients in group I received 20 mL of 0.25% bupivacaine, whereas patients in group II received 20 mL of 0.125% bupivacaine for TAP block at the end of the surgery. Pain intensity was assessed at rest and during coughing using 10-cm visual analog scale score at 5, 15, 30, and 45 minutes and 1, 2, 4, 6, 12, and 24 hours after TAP block. Morphine consumption and time to first morphine requirement were recorded. Visual analog scale scores at rest and during coughing were not significantly different between groups at all time points measured. Twenty-four hours of morphine consumption (7.72±7.33 mg in group I and 6.06±5.20 mg in group II; P=.437) and time to first morphine requirement (182.35±125.16 minutes in group I and 143.21±87.28 minutes in group II; P=.332) were not different between groups. 0.125% Bupivacaine provides similar analgesic effect compared to 0.25% bupivacaine for ultrasound-guided TAP block in patients undergoing open inguinal hernia repair. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. [Subcostal transversus abdominis plane block can improve analgesia after laparoscopic cholecystectomy].

    PubMed

    Vrsajkov, Vladimir; Mančić, Nedjica; Mihajlović, Dunja; Milićević, Suzana Tonković; Uvelin, Arsen; Vrsajkov, Jelena Pantić

    After laparoscopic cholecystectomy, patients have moderate pain in the early postoperative period. Some studies shown beneficial effects of subcostal transversus abdominis plane block on reducing this pain. Our goal was to investigate influence of subcostal transversus abdominis plane block on postoperative pain scores and opioid consumption. We have randomized 76 patients undergoing laparoscopic cholecystectomy to receive either subcostal transversus abdominis plane block (n=38) or standard postoperative analgesia (n=38). First group received bilateral ultrasound guided subcostal transversus abdominis plane block with 20mL of 0.33% bupivacaine per side before operation and tramadol 1mg.kg -1 IV for pain breakthrough (≥6). Second group received after operation tramadol 1mg.kg -1 /6h as standard hospital analgesia protocol. Both groups received acetaminophen 1g/8h IV and metamizole 2.5g/12h. Pain at rest was recorded for each patient using NR scale (0-10) in period of 10min, 30min, 2h, 4h, 8h, 12h and 16h after the surgery. We obtained no difference between groups according age, weight, intraoperative fentanyl consumption and duration of surgery. Subcostal transversus abdominis plane block significantly reduced postoperative pain scores compared to standard analgesia in all periods after surgery. Tramadol consumption was significantly lower in the subcostal transversus abdominis plane (24.29±47.54g) than in the standard analgesia group (270.2±81.9g) (p=0.000). Our results show that subcostal transversus abdominis plane block can provide superior postoperative analgesia and reduction in opioid requirements after laparoscopic cholecystectomy. Copyright © 2017 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All rights reserved.

  3. Effects of preoperative ultrasound-guided transversus abdominis plane block on pain after laparoscopic surgery for colorectal cancer: a double-blind randomized controlled trial.

    PubMed

    Oh, Tak Kyu; Yim, Jiyeon; Kim, Jaehyun; Eom, Woosik; Lee, Soon Ae; Park, Sung Chan; Oh, Jae Hwan; Park, Ji Won; Park, Boram; Kim, Dae Hyun

    2017-01-01

    Although laparoscopic colorectal surgery decreases postoperative pain and facilitates a speedier recovery compared with laparotomy, postoperative pain at trocar insertion sites remains a clinical concern. The objective of this study was to assess the effects of a preoperative ultrasound-guided transversus abdominis plane (TAP) block on pain after laparoscopic surgery for colorectal cancer. In total, 58 patients scheduled to undergo laparoscopic surgery following a diagnosis of colorectal cancer were included in this study. The patients were randomized into TAP and control groups; the TAP group patients received a preoperative ultrasound-guided bilateral TAP block with 0.5 mL/kg of 0.25 % bupivacaine, while the control patients received the block with an equal amount of saline. Pain on coughing and at rest was assessed during postanesthetic recovery (PAR; 1 h after surgery) and on postoperative days (PODs) 1 (24 h), 2 (48 h), and 3 (72 h) by an investigator blinded to group allocations using the numeric rating scale (NRS). The primary outcome was pain on coughing on postoperative day (POD) 1. Fifty-five patients were included in the final analysis, including 28 in the TAP and 27 in the control groups. The pain intensity on coughing and at rest during PAR and on PODs 1, 2, and 3 showed no significant differences between groups. Furthermore, there was no significant difference in postoperative opioid consumption, sedation scores, nausea scores at the four time points, complication rates, and length of hospital stay between groups. In colorectal cancer patients undergoing laparoscopic colorectal surgery, a TAP block did not offer enough benefit for clinical efficacy in terms of postoperative pain or analgesic consumption.

  4. Therapeutic results after ultrasound-guided intratissue percutaneous electrolysis (EPI®) in the treatment of rectus abdominis-related groin pain in professional footballers: a pilot study.

    PubMed

    Moreno, Carlos; Mattiussi, Gabriele; Núñez, Francisco J

    2016-10-01

    Rectus abdominis-related groin pain (RAGP) is one of the possible clinical patterns that determine pubalgia. RAGP is one of the typical patterns in footballers and is due to the degeneration and tendinopathy of the distal tendon, at the level of the two pubic tubercles. Intratissue percutaneous electrolysis (EPI) is a novel technique used in the treatment of tendinopathies. The aim of this study was to examine the therapeutic benefits of EPI by contrasting the two basic components that characterize RAGP: painful symptoms and resultant functional deficits. Eight professional footballers at Udinese Calcio Spa Football Club underwent ultrasound-guided EPI intervention. No other type of treatment was combined with EPI. Pain was monitored with the Verbal Rating Scale, while functional deficit was monitored using the Patient Specific Functional Scale. The scales implementation took place before treatment, then 24 hours, 1 week, 1 month and 6 months after the end of treatment. Treatment with EPI produced a complete reduction of pain symptoms in one month and enabled excellent functional recovery for walking and jogging in one week; for getting out of bed, running, jumping and kicking within one month from the end of the treatment. Treatment with ultrasound-guided EPI has shown encouraging clinical results for RAGP. Data are preliminary: considering the limitations of this study more complex design studies are necessary to test the efficacy of the technique. This study introduces the EPI technique for the first time in the treatment of professional footballers suffering from RAGP. Its future use is proposed as a treatment solution, including complementary to conservative treatment.

  5. Successful Treatment of Abdominal Cutaneous Entrapment Syndrome Using Ultrasound Guided Injection

    PubMed Central

    Hong, Myong Joo; Seo, Dong Hyuk

    2013-01-01

    There are various origins for chronic abdominal pain. About 10-30% of patients with chronic abdominal pain have abdominal wall pain. Unfortunately, abdominal wall pain is not thought to be the first origin of chronic abdominal pain; therefore, patients usually undergo extensive examinations, including diagnostic laparoscopic surgery. Entrapment of abdominal cutaneous nerves at the muscular foramen of the rectus abdominis is a rare cause of abdominal wall pain. If abdominal wall pain is considered in earlier stage of chronic abdominal pain, unnecessary invasive procedures are not required and patients will reach symptom free condition as soon as the diagnosis is made. Here, we report a case of successful treatment of a patient with abdominal cutaneous nerve entrapment syndrome by ultrasound guided injection therapy. PMID:23862004

  6. A comparative study to evaluate ultrasound-guided transversus abdominis plane block versus ilioinguinal iliohypogastric nerve block for post-operative analgesia in adult patients undergoing inguinal hernia repair.

    PubMed

    Kamal, Kirti; Jain, Parul; Bansal, Teena; Ahlawat, Geeta

    2018-04-01

    Both transversus abdominis plane (TAP) block and combined ilioinguinal-iliohypogastric (IIN/IHN) blocks are used routinely under ultrasound (USG) guidance for postoperative pain relief in patients undergoing inguinal hernia surgery. This study compares USG guided TAP Vs IIN/IHN block for post-operative analgesic efficacy in adults undergoing inguinal hernia surgery. Sixty adults aged 18 to 60 with American Society of Anesthesiologsts' grade I or II were included. After general anaesthesia, patients in Group I received USG guided unilateral TAP block using 0.75% ropivacaine 3 mg/kg (maximum 25 mL) and those in Group II received IIN/IHN block using 10 mL 0.75% ropivacaine. Postoperative rescue analgesia was with tramadol (intravenous) IV ± diclofenac IV in the first 4 h followed by oral diclofenac subsequently. Total analgesic consumption in the first 24 h was the primary objective, intraoperative haemodynamics, number of attempts and time required for performing the block as well as the postoperative pain scores were also evaluated. Time to first analgesic request was 319.8 ± 115.2 min in Group I and 408 ± 116.4 min in Group II ( P = 0.005). Seven patients (23.33%) in Group I and two (6.67%) in Group II required tramadol in first four hours. No patient in either groups received diclofenac IV. The average dose of tablet diclofenac was 200 ± 35.96 mg in Group I and 172.5 ± 34.96 mg in Group II ( P = 0. 004). USG guided IIN/IHN block reduces the postoperative analgesic requirement compared to USG guided TAP block.

  7. Adding a transversus abdominis plane block to parenteral opioid for postoperative analgesia following trans-abdominal hysterectomy in a low resource setting: a prospective, randomised, double blind, controlled study.

    PubMed

    Moyo, Nomaqhawe; Madzimbamuto, Farai D; Shumbairerwa, Samson

    2016-01-28

    The current gold standard treatment for acute postoperative pain after major abdominal surgery is multimodal analgesia using patient controlled analgesia delivery systems. Patient controlled analgesia systems are expensive and their routine use in very low income countries is not practical. The use of ultrasound in anaesthesia has made some regional anaesthesia blocks technically easy and safe to perform. This study aimed to determine whether adding an ultrasound guided transversus abdominis plane block as an adjunct to the current parenteral opioid based regimen would result in superior pain relief after a trans abdominal hysterectomy compared to using parenteral opioids alone. Thirty-two elective patients having trans abdominal hysterectomy were recruited into a prospective randomised double-blind, controlled study comparing a bilateral transversus abdominis plane block using 21 ml of 0.25% bupivacaine and 4.0 mg dexamethasone with a sham block containing 21 ml 0.9% saline. Sixteen patients were allocated to each group. Anaesthesia and postoperative analgesia was left to the attending anaesthetist's discretion. Primary outcome was visual analogue scale for pain at 2 h and 4 h. Secondary outcomes were time to first request for analgesia, visual analogue scale for comfort and bother. The data were analysed using the Statistical Package for Social Sciences (SPSS version 16). There was no statistically significant difference in the demographics of the two groups regarding weight, height, physical status and type of surgical incision. There was a statistically significant difference in visual analogue scale for pain at 4 h during movement with lower pain scales in the test group (p = 0.034). Women in the control group had an average pain free period of 56.8 min (median 56.5 min) before requesting a rescue analgesic compared to 116.5 min (median 103 min) in the study group. The between group difference in the average total analgesia duration was statistically significant at the 0.05 level (p = 0.005). The addition of a bupivacaine-dexamethasone transverse abdominis plane block to intramuscular opioid does produce superior acute post-operative pain relief following a hysterectomy. However a single-shot block has a limited duration of action, and we recommend a repeat block. Clinical trials registration was obtained PACTR201501000965252. http//www.pactr.org/ATMWeb/appmanager/atm/atmregistry?_nfpb=true&_windowLabel=BasicSearchUpdateController_1&BasicSearchUpdateController_1_actionOverride=%2Fpageflows%2Ftrial%2FbasicSearchUpdate%2FviewTrail&BasicSearchUpdateController_1id=965. The trial was registered on the 12th Dec 2014.

  8. Spread of Quadratus Lumborum Block to the Paravertebral Space Via Intramuscular Injection: A Volunteer Study.

    PubMed

    Tamura, Takahiro; Kitamura, Kana; Yokota, Shuichi; Ito, Shigeki; Shibata, Yasuyuki; Nishiwaki, Kimitoshi

    2018-05-01

    Several types of quadratus lumborum block (QLB) are used for postoperative analgesia and are believed to be effective against both somatic and visceral pain via a local anesthetic (LA) effect in the paravertebral space (PVS). However, it remains unclear whether all QLB techniques result in LA spread into the PVS. We hypothesized that LA administered via intramuscular QLB would spread into the paravertebral space and investigated the spread and sensory block area of LA in intramuscular QLB. This volunteer study included 5 healthy men and 1 woman, with no previous medical history. Intramuscular QLB and lateral transversus abdominis plane block were performed under real-time ultrasound guidance for comparison of sensory deprivation range. Two days later, the same procedure was performed on the contralateral side of the body. The spread of LA via intramuscular QLB spread to the PVS was assessed 1 hour after the first injections using magnetic resonance imaging. Sensory perception was also evaluated by the pinprick test at 90 minutes after injection. In total, we performed 11 intramuscular QLBs and 11 lateral transversus abdominis plane blocks. Magnetic resonance imaging showed that LA did not spread into the PVS after ultrasound-guided intramuscular QLB. The analgesic area corresponded to the side of the body that was ipsilateral to the block. Ultrasound-guided intramuscular QLBs are not clinically useful for procedures requiring LA spread into the PVS but do result in an ipsilateral analgesic effect in healthy volunteers. This study was registered at University Hospital Medical Information Network Clinical Trials Registry, UMIN 000019149.

  9. A comparison of longitudinal and transverse approaches to ultrasound-guided axillary vein cannulation by experienced operators.

    PubMed

    He, Yi-Zhou; Zhong, Ming; Wu, Wei; Song, Jie-Qiong; Zhu, Du-Ming

    2017-04-01

    The axillary vein is an easily accessible vessel that can be used for ultrasound-guided central vascular access and offers an alternative to the internal jugular and subclavian veins. The objective of this study was to identify which transducer orientation, longitudinal or transverse, is better for imaging the axillary vein with ultrasound. We analyzed 236 patients who had undergone central venous cannulation of axillary vein in this retrospective study. Patients were divided into two groups, the longitudinal approach group (n=120) and transverse approach group (n=116). Recorded the one-attempt success rate, operation time, arterial puncture rate and pneumothorax rate. We perform chest radiography to confirm pneumothorax on all patients. We compared the one-attempt success rate, operation time, arterial puncture rate and pneumothorax rate between the two groups. The two groups were comparable with clinical characters of patients. The overall success rates of the longitudinal group and the transverse group were both 100%. The rate of one-attempt success in the longitudinal approach group is higher than the transverse approach group (91.7% vs. 82.8%, P=0.040). The transverse approach group had shorter operation time than the longitudinal group (184.7±8.1 vs. 287.5±19.6 seconds, P=0.000). The two groups had lower postoperative complications. Arterial puncture occurred in 1 of 120 longitudinal and 2 of 116 transverse attempts and this difference was no significant (P=0.541). No pneumothorax occurred in the two groups. The longitudinal approach during ultrasound-guided axillary vein cannulation is associated with greater one-attempt success rate compared with the transverse approach by experienced operators. The transverse approach has shorter operation time. The two groups have lower postoperative complications and are comparable with pneumothorax and arterial puncture.

  10. Ultrasonographic percutaneous anatomy of the atlanto-occipital region and indirect ultrasound-guided cisternal puncture in the dog and the cat.

    PubMed

    Etienne, A-L; Audigié, F; Peeters, D; Gabriel, A; Busoni, V

    2015-04-01

    Cisternal puncture in dogs and cats is commonly carried out. This article describes the percutaneous ultrasound anatomy of the cisternal region in the dog and the cat and an indirect technique for ultrasound-guided cisternal puncture. Ultrasound images obtained ex vivo and in vivo were compared with anatomic sections and used to identify the landmarks for ultrasound-guided cisternal puncture. The ultrasound-guided procedure was established in cadavers and then applied in vivo in seven dogs and two cats. The anatomic landmarks for the ultrasound-guided puncture are the cisterna magna, the spinal cord, the two occipital condyles on transverse images, the external occipital crest and the dorsal arch of the first cervical vertebra on longitudinal images. Using these ultrasound anatomic landmarks, an indirect ultrasound-guided technique for cisternal puncture is applicable in the dog and the cat. © 2014 Blackwell Verlag GmbH.

  11. Ultrasound-guided rectus sheath and transversus abdominis plane blocks for perioperative analgesia in upper abdominal surgery: A randomized controlled study.

    PubMed

    Abdelsalam, Khaled; Mohamdin, O W

    2016-01-01

    Regional anesthetic techniques can be used to alleviate postoperative pain in patients undergoing major upper abdominal surgery. Our aim was to evaluate the efficacy of bilateral ultrasound (US)-guided rectus sheath (RS) and transversus abdominis plane (TAP) blocks for better perioperative analgesia. It is a prospective, observer-blinded, randomized clinical study. 40 eligible patients undergoing elective liver resection or Whipple procedure were included. All patients received a standardized anesthetic technique. Group 1 (n = 20) received preincisional US-guided bilateral RS and TAP blocks using 20 ml volume of bupivacaine 0.25% for each, and group 2 (n = 20) received local wound infiltration at end of surgery with 40 ml of bupivacaine 0.25%. A standardized postoperative analgesic regimen composed of intravenous paracetamol and a morphine patient-controlled analgesia (PCA). The use of intraoperative fentanyl and recovery room morphine boluses, PCA-administered morphine, pain scores as well as number of patients' experienced postoperative nausea and vomiting in the ward at 6 and 24 h were recorded. Group 1 patients received a significantly lower cumulative intraoperative fentanyl, significantly lesser boluses of morphine in postanesthesia care unit, as well, significantly lower cumulative 24 h postoperative morphine dosage than the group 2 patients. Pain visual analog scale scores were significantly lower at both 6 and 24 h postoperatively in TAP group when compared with the no-TAP group. There were no complications related to the TAP block procedures. No signs or symptoms of local anesthetic systemic toxicity were detected. The combination of bilateral US-guided RS and TAP blocks provides excellent perioperative analgesia for major upper abdominal surgery.

  12. Ultrasound-guided suprascapular nerve block: a correlation with fluoroscopic and cadaveric findings.

    PubMed

    Peng, Philip W H; Wiley, Michael J; Liang, James; Bellingham, Geoff A

    2010-02-01

    Previous work on the ultrasound-guided injection technique and the sonoanatomy of the suprascapular region relevant to the suprascapular nerve (SSN) block suggested that the ultrasound scan showed the presence of the suprascapular notch and transverse ligament. The intended target of the ultrasound-guided injection was the notch. The objective of this case report and the subsequent cadaver dissection findings is to reassess the interpretation of the ultrasound images when locating structures for SSN block. A 45-yr-old man with chronic shoulder pain received an ultrasound-guided SSN block using the suprascapular notch as the intended target. The position of the needle was verified by fluoroscopy, which showed the tip of the needle well outside the suprascapular notch. Similar ultrasound-guided SSN blocks were performed in two cadavers. Dissections were performed which showed that the needle tips were not at the suprascapular notch but, more accurately, were close to the SSN but at the floor of the suprascapular fossa between the suprascapular and spinoglenoid notch. Our fluoroscopic and cadaver dissection findings both suggest that the ultrasound image of the SSN block shown by the well-described technique is actually targeting the nerve on the floor of the suprascapular spine between the suprascapular and spinoglenoid notches rather than the suprascapular notch itself. The structure previously identified as the transverse ligament is actually the fascia layer of the supraspinatus muscle.

  13. Right Lower Quadrant Pain in a Young Female: Ultrasound Diagnosis of Rectus Abdominis Tear.

    PubMed

    Minardi, Joseph; Shaver, Erica; Monseau, Aaron; Pratt, Adam; Layman, Shelley M

    2015-11-01

    Right lower quadrant pain in young females presents a frequent diagnostic challenge for emergency physicians, with a broad differential and several important diagnoses. Using an "ultrasound first" imaging strategy can help decrease the use of computed tomography scans, with associated savings in radiation exposure, cost, and other resource use. We report a case of right lower quadrant pain in a young woman. After her initial history and physical examination, appendicitis was the leading differential. A bedside ultrasound was performed, leading to the uncommon diagnosis of rectus abdominis muscle tear. The sonographic findings of a muscle tear include increase in size, loss of linear, homogeneous architecture, and decreased echogenicity. Making this diagnosis at the bedside using ultrasound obviated the need for further imaging, avoiding unnecessary radiation exposure, and decreasing emergency department length of stay and overall cost, while leading to a tailored treatment plan. Why Should an Emergency Physician Be Aware of This? Rectus abdominis tear is a cause of right lower quadrant pain that may mimic appendicitis and should be considered in patients with this complaint. The ability to make this diagnosis with bedside ultrasound may assist in several important patient-oriented outcomes. Copyright © 2015 Elsevier Inc. All rights reserved.

  14. A comparison of longitudinal and transverse approaches to ultrasound-guided axillary vein cannulation by experienced operators

    PubMed Central

    He, Yi-Zhou; Zhong, Ming; Wu, Wei; Song, Jie-Qiong

    2017-01-01

    Background The axillary vein is an easily accessible vessel that can be used for ultrasound-guided central vascular access and offers an alternative to the internal jugular and subclavian veins. The objective of this study was to identify which transducer orientation, longitudinal or transverse, is better for imaging the axillary vein with ultrasound. Methods We analyzed 236 patients who had undergone central venous cannulation of axillary vein in this retrospective study. Patients were divided into two groups, the longitudinal approach group (n=120) and transverse approach group (n=116). Recorded the one-attempt success rate, operation time, arterial puncture rate and pneumothorax rate. We perform chest radiography to confirm pneumothorax on all patients. We compared the one-attempt success rate, operation time, arterial puncture rate and pneumothorax rate between the two groups. Results The two groups were comparable with clinical characters of patients. The overall success rates of the longitudinal group and the transverse group were both 100%. The rate of one-attempt success in the longitudinal approach group is higher than the transverse approach group (91.7% vs. 82.8%, P=0.040). The transverse approach group had shorter operation time than the longitudinal group (184.7±8.1 vs. 287.5±19.6 seconds, P=0.000). The two groups had lower postoperative complications. Arterial puncture occurred in 1 of 120 longitudinal and 2 of 116 transverse attempts and this difference was no significant (P=0.541). No pneumothorax occurred in the two groups. Conclusions The longitudinal approach during ultrasound-guided axillary vein cannulation is associated with greater one-attempt success rate compared with the transverse approach by experienced operators. The transverse approach has shorter operation time. The two groups have lower postoperative complications and are comparable with pneumothorax and arterial puncture. PMID:28523170

  15. Muscle mass and composition of the hip, thigh and abdominal muscles in women with and without hip osteoarthritis.

    PubMed

    Fukumoto, Yoshihiro; Ikezoe, Tome; Tateuchi, Hiroshige; Tsukagoshi, Rui; Akiyama, Haruhiko; So, Kazutaka; Kuroda, Yutaka; Yoneyama, Tomohide; Ichihashi, Noriaki

    2012-09-01

    The objective of this study was to compare muscle mass and composition between individuals with and without hip osteoarthritis. Twenty-four women with hip osteoarthritis (OA group) and 16 healthy women (healthy group) participated in this study. Muscle thickness (MT) and echo intensity (EI) were measured as indices of muscle mass and composition, respectively, using ultrasound imaging. Seven muscles were examined: gluteus maximus, gluteus medius, quadriceps femoris, rectus abdominis, external oblique, internal oblique and transversus abdominis. MT of only quadriceps femoris in the OA group was significantly thinner than that in the healthy group. EIs of gluteus medius, quadriceps femoris and rectus abdominis were significantly higher in the OA group than those in the healthy group. Thus, actual contractile tissue of gluteus medius and rectus abdominis substantially decreased, although muscle mass was similar, whereas both quantitative and qualitative changes occurred in quadriceps femoris in patients with hip OA. Copyright © 2012 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  16. Rectus abdominis atrophy after ventral abdominal incisions: midline versus chevron.

    PubMed

    Vigneswaran, Y; Poli, E; Talamonti, M S; Haggerty, S P; Linn, J G; Ujiki, M B

    2017-08-01

    Although many outcomes have been compared between a midline and chevron incision, this is the first study to examine rectus abdominis atrophy after these two types of incisions. Patients undergoing open pancreaticobiliary surgery between 2007 and 2011 at our single institution were included in this study. Rectus abdominis muscle thickness was measured on both preoperative and follow-up computed tomography (CT) scans to calculate percent atrophy of the muscle after surgery. At average follow-up of 24.5 and 19.0 months, respectively, rectus abdominis atrophy was 18.9% greater in the chevron (n = 30) than in the midline (n = 180) group (21.8 vs. 2.9%, p < 0.0001). Half the patients with a chevron incision had >20% atrophy at follow-up compared with 10% with a midline incision [odds ratio (OR) 9.0, p < 0.0001]. No significant difference was observed in incisional hernia rates or wound infections between groups. In this study, chevron incisions resulted in seven times more atrophy of the rectus abdominis compared with midline incisions. The long-term effects of transecting the rectus abdominis and disrupting its innervation creates challenging abdominal wall pathology. Atrophy of the abdominal wall can not be readily fixed with an operation, and this significant side effect of a transverse incision should be factored into the surgeon's decision-making process when choosing a transverse over a midline incision.

  17. Onset in abdominal muscles recorded simultaneously by ultrasound imaging and intramuscular electromyography.

    PubMed

    Vasseljen, Ottar; Fladmark, Anne M; Westad, Christian; Torp, Hans G

    2009-04-01

    Delayed onset of muscle activity in abdominal muscles has been related to low back pain. To investigate this in larger clinical trials it would be beneficial if non-invasive and less cumbersome alternatives to intramuscular electromyography (EMG) were available. This study was designed to compare onset of muscle activity recorded by intramuscular EMG to onset of muscle deformations by ultrasound imaging. Muscle deformations were recorded by two ultrasound imaging modes at high time resolution (m-mode and tissue velocity) in separate sessions and compared to simultaneously recorded intramuscular EMG in three abdominal muscles. Tissue velocity imaging was converted to strain rate which measures deformation velocity gradients within small regions, giving information about the rate of local tissue shortening or lengthening along the beam axis. Onsets in transversus abdominis (TrA), obliquus internus abdominis (OI) and obliquus externus abdominis (OE) were recorded during rapid arm flexions in ten healthy subjects. During ultrasound m-mode recordings, the results showed that mean onsets by EMG were detected 7 ms (95% CI of mean difference; +/-4 ms) and 2 ms (95% CI of mean difference; +/-6 ms) before concurrent ultrasound m-mode detected onsets in TrA and OI, respectively. In contrast, OE onset was recorded 54 ms (95% CI of bias; +/-16 ms) later by EMG compared to ultrasound m-mode. The discrepancy of ultrasound m-mode to accurately record onset in OE was practically corrected in the ultrasound-based strain rate recordings. However, this could only be applied on half of the subjects due to the angle dependency between the ultrasound beam and the direction of the contraction in strain rate recordings. The angle dependency needs to be further explored.

  18. Normal postural responses preceding shoulder flexion: co-activation or asymmetric activation of transverse abdominis?

    PubMed

    Davarian, Sanaz; Maroufi, Nader; Ebrahimi, Esmaeil; Parnianpour, Mohammad; Farahmand, Farzam

    2014-01-01

    It is suggested that activation of the transverse abdominis muscle has a stabilizing effect on the lumbar spine by raising intra-abdominal pressure without added disc compression. However, its feedforward activity has remained a controversial issue. In addition, research regarding bilateral activation of trunk muscles during a unilateral arm movement is limited. The aim of this study was to evaluate bilateral anticipatory activity of trunk muscles during unilateral arm flexion. Eighteen healthy subjects (aged 25 ± 3.96 years) participated in this study and performed 10 trials of rapid arm flexion in response to a visual stimulus. The electromyographic activity of the right anterior deltoid (AD) and bilateral trunk muscles including the transverse abdominis/internal oblique (TA/IO), superficial lumbar multifidus (SLM) and lumbar erector spine (LES) was recorded. The onset latency and anticipatory activity of the recorded trunk muscles were calculated. The first muscle activated in anticipation of the right arm flexion was the left TA/IO. The right TA/IO activated significantly later than all other trunk muscles (P < 0.0005). In addition, anticipatory activity of the right TA/IO was significantly lower than all other trunk muscles (P < 0.0005). There was no significant difference in either onset latency or anticipatory activity among other trunk muscles (P > 0.05). Healthy subjects showed no bilateral anticipatory co-activation of TA/IO in unilateral arm elevation. Further investigations are required to delineate normal muscle activation pattern in healthy subjects prior to prescribing bilateral activation training of transverse abdominis for subjects with chronic low back pain.

  19. Efficacy of ultrasound-guided transversus abdominis plane block in laparoscopic hysterectomy. Clinical trial.

    PubMed

    Guardabassi, D S; Lupi, S; Agejas, R; Allub, J M; García-Fornari, G

    2017-05-01

    Transversus abdominis plane block is a regional anaesthesia technique that has proven to be effective for postoperative pain reduction in different abdominal surgical procedures. This study evaluated its efficacy on post laparoscopic hysterectomy pain intensity and analgesic consumption. Randomized controlled trial which included 40 patients scheduled for laparoscopic hysterectomy, enrolled in 2 groups: transversus abdominis plane block+systemic analgesia (Group 1; n=20), versus systemic analgesia (Group 2; n=20). Opioid consumption within the first 24 postoperative hours, pain intensity scores at 60min, 2, 8 and 24h after surgery, adverse events related to systemic analgesia and time to hospital discharge were evaluated and registered. We found no differences between both groups in opioid consumption (10mg vs. 7mg; P=.2) and pain scores (NVS) within the first 24 postoperative hours, at 60min (3 vs. 5; P=.65), 120min (0 vs. 2; P=.15), 8 and 24h (0 vs. 0; P>.50) for the last 2 points in time analysed. Adverse events related to medication and time to hospital discharge showed similar results. Adding a transversus abdominis plane block technique to opioid PCA does not seem to improve postoperative pain management in laparoscopic hysterectomy. Patient preparation time and costs could be incremented and complications (although rare) related to the technique could appear. Copyright © 2017 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  20. [Case of Leriche's syndrome treated with safe and effective analgesia after laparotomy by transversus abdominis plane block, rectus sheath block, and continuous wound infusion with ropivacaine].

    PubMed

    Hotta, Arisa; Yagi, Yuuki; Hakata, Saaya; Tsumura, Yae; Shimizu, Motoko; Kukida, Ayako; Nakamoto, Ai; Yoshikawa, Noriko; Oohira, Naoko; Tatekawa, Shigeki

    2013-12-01

    Ultrasound-guided peripheral nerve blocks in the abdominal wall, such as transversus abdominis plane block (TAP block) and rectus sheath block, are now widely used. We report a case of Leriche's syndrome treated with safe and effective analgesia after laparotomy by abdominal wall block and continuous infusion. A 61-year-old man diagnosed with Leriche's syndrome underwent Y-graft replacement for an abdominal aortic aneurysm. Preoperative enhanced and 3-dimensional CTs showed many collateral arterial systems, especially in the right abdominal wall. It was suggested that the right internal iliac artery had been completely occluded, and the left one showed severe stenosis. After the induction of general anesthesia, we recognized collateral arteries through an ultrasound view as on preoperative CTs. We lowered the pulse repetition frequency more than usual in order not to injure them. We injected 0.1875% ropivacaine 60 ml as TAP block, and 20 ml as rectus sheath block. When the wound was closed, a catheter was passed through an 18-gauge Tuohy needle placed above the fascia along the supraumbilical site. After the operation, 0.2% ropivacaine was continuously delivered at a rate of 6 ml hr-1 through the catheter. We could provide the patient with effective analgesia after surgery.

  1. Comparison of Epidural Analgesia with Transversus Abdominis Plane Analgesia for Postoperative Pain Relief in Patients Undergoing Lower Abdominal Surgery: A Prospective Randomized Study.

    PubMed

    Iyer, Sadasivan Shankar; Bavishi, Harshit; Mohan, Chadalavada Venkataram; Kaur, Navdeep

    2017-01-01

    Anesthesiologists play an important role in postoperative pain management. For analgesia after lower abdominal surgery, epidural analgesia and ultrasound-guided transversus abdominis plane (TAP) block are suitable options. The study aims to compare the analgesic efficacy of both techniques. Seventy-two patients undergoing lower abdominal surgery under spinal anesthesia were randomized to postoperatively receive lumbar epidural catheter (Group E) or ultrasound-guided TAP block (Group T) through intravenous cannulas placed bilaterally. Group E received 10 ml 0.125% bupivacaine stat and 10 ml 8 th hourly for 48 h. Group T received 20 ml 0.125% bupivacaine bilaterally stat and 20 ml bilaterally 8 th hourly for 48 h. Pain at rest and on coughing, total paracetamol and tramadol consumption were recorded. Analgesia at rest was comparable between the groups in the first 16 h. At 24 and 48 h, Group E had significantly better analgesia at rest ( P = 0.001 and 0.004 respectively). Patients in Group E had significantly higher number of patients with nil or mild pain on coughing at all times. Paracetamol consumption was comparable in both groups, but tramadol consumption was significantly higher in Group T at the end of 48 h ( P = 0.001). For lower abdominal surgeries, analgesia provided by intermittent boluses of 0.125% is comparable for first 16 h between epidural and TAP catheters. However, the quality of analgesia provided by the epidural catheter is superior to that provided by TAP catheters beyond that both at rest and on coughing with reduced opioid consumption.

  2. Postoperative analgesic efficiency of transversus abdominis plane block after ventral hernia repair: a prospective, randomized, controlled clinical trial.

    PubMed

    Chesov, Ion; Belîi, Adrian

    2017-10-01

    Effective postoperative analgesia is a key element in reducing postoperative morbidity, accelerating recovery and avoiding chronic postoperative pain. The aim of this study was to evaluate the effectiveness of ultrasound-guided Transversus Abdominis Plane (TAP) block, performed before surgical incision, in providing postoperative analgesia for patients undergoing open ventral hernia repair under general anaesthesia. Seventy elective patients scheduled for open ventral hernia repair surgery under general anaesthesia were divided randomly into two equal groups: Group I received bilateral TAP block performed before surgical incision (n = 35); Group II received systemic postoperative analgesia with parenteral opioid (morphine) alone (n = 35). Postoperatively pain scores at rest and with movement, total morphine consumption and opioid related side effects were recorded. Postoperative pain scores at rest and mobilization/cough were significantly higher in patients without TAP block (p < 0.05). Mean intraoperative fentanyl consumption was comparable between the two groups: 0.75 ± 0.31 mg in group I (TAP) and 0.86 ± 0.29 mg in group II (MO), p = 0.1299. Patients undergoing preincisional TAP block had reduced morphine requirements during the first 24 hours after surgery, compared to patients from group II, without TAP block (p = 0.0001). There was no difference in the incidence of opioid related side effects (nausea, vomiting) in the both groups during the first 24 postoperative hours. The use of preincisional ultrasound guided TAP block reduced the pain scores at rest and with movement/cough, opioid consumption and opioid-related side effects after ventral hernia repair when compared with opioid-only analgesia.

  3. The ultrasound-guided nerve blocks of abdominal wall contributed to anesthetic management of cholecystectomy in a patient with Becker muscular dystrophy without using muscle relaxants.

    PubMed

    Iwata, Masato; Kuzumoto, Naoya; Akasaki, Yuka; Morioka, Masayo; Nakayama, Kana; Matsuzawa, Nobuyoshi; Kimoto, Katsuhiro; Shimomura, Toshiyuki

    2017-01-01

    Becker muscular dystrophy (BMD) is a progressive neuromuscular disorder caused by mutations in the dystrophin gene. The sensitivity to non-depolarizing muscle relaxant in a patient with muscle dystrophy is reportedly higher than that in normal individuals, and the duration of the effect is known to be prolonged. In this report, we present the case of a 58-year-old man with BMD who underwent laparoscopic cholecystectomy for symptomatic cholelithiasis under total intravenous anesthesia without the use of muscle-relaxant drugs and supplemented with regional anesthesia. Anesthesia was induced and maintained with propofol, remifentanil, and fentanyl; ultrasound-guided bilateral rectus sheath block (RSB) and right-sided subcostal transversus abdominis plane block (TAP) were performed. The procedure required conversion to open surgery because of hard conglutination; intraoperative and postoperative periods were uneventful. Adequate analgesia was maintained after extubation because of the effect of RSB and TAP.

  4. Chronic abdominal wall pain and ultrasound-guided abdominal cutaneous nerve infiltration: a case series.

    PubMed

    Kanakarajan, Saravanakumar; High, Kristina; Nagaraja, Ravi

    2011-03-01

    Chronic abdominal wall pain occurs in about 10-30% of patients presenting with chronic abdominal pain. Entrapment of abdominal cutaneous nerves at the lateral border of the rectus abdominis muscle has been attributed as a cause of abdominal wall pain. We report our experience of treating such patients using ultrasound-guided abdominal cutaneous nerve infiltration. We conducted a retrospective audit of abdominal cutaneous nerve infiltration performed in the period between September 2008 to August 2009 in our center. All patients had received local anesthetic and steroid injection under ultrasound guidance. The response to the infiltration was evaluated in the post-procedure telephone review as well as in the follow-up clinic. Brief pain inventory (BPI) and numerical rating scale pain scores were collated from two points: the initial outpatient clinic and the follow up clinic up to 5 months following the injection. Nine patients had abdominal cutaneous nerve injections under ultrasound guidance in the period under review. Six patients reported 50% pain relief or more (responders) while three patients did not. Pain and BPI scores showed a decreasing trend in responders. The median duration of follow-up was 12 weeks. Ultrasound can reliably be used for infiltration of the abdominal cutaneous nerves. This will improve the safety as well as diagnostic utility of the procedure. Wiley Periodicals, Inc.

  5. The analgesic efficacy of subcostal transversus abdominis plane block with Mercedes incision.

    PubMed

    Guo, Jian-Guo; Li, Hui-Ling; Pei, Qing-Qing; Feng, Zhi-Ying

    2018-04-10

    Conventional perioperative analgesic modalities (e.g. opioids, epidural analgesia) have their own drawbacks, which limit their clinical application. This study investigated the opioid-sparing effectsof the oblique subcostal transversus abdominis plane (OSTAP) blockade with ropivacaine for the patients undergoing open liver resection with a Mercedes incision. 126 patients who were scheduled for open liver resection were enrolled in this study. Patients were randomly assigned to receive bilateral ultrasound-guided OSTAPblocks with either 0.375% ropivacaine (groupT) or 0.9% isotonic saline (group C). Both groups also received intravenous patient-controlled analgesia and intravenous 40 mg parecoxib every 12 h for a total of 3 days. Preoperative and intraoperative parameters, plus intraoperative and postoperative cumulative sufentanil consumption, were recorded. 70 patients were enrolled in the study finally. There were no significant differences between the two groups with respect to preoperative parameters, and surgical and anesthetic characteristics. The intraoperative sufentanil use, cumulative sufentanil consumption at 5 min after extubation, 2 h, 4 h,12 h and 24 h after operation in group T was significantly less than that in group C (P = 0.001, 0.001, 0.000, 0.000, 0.001 and 0.044, respectively). Compared with group C, postoperative NRS pain scores at rest were significantly lower at 2 h and 4 h postoperatively in group T (P = 0.04and 0.02, respectively); NRS scores at the time of coughing were also significantly lower in group T than in group C at all time points except 5 min after extubation (all P < 0.001). Furthermore, compared with group C, the number of intraoperative vasodilator use, the extubation time and the incidence of nausea was reduced in group T. Ultrasound-guided OSTAP block with ropivacaine can significantly decrease the perioperative cumulative dosage of analgesics and improve analgesic effect without obvious side effects for the patients who underwent an open liver resection with Mercedes incision when compared tothe ultrasound-guided OSTAP block with saline. The study protocol was registered at http://www.chictr.org.cn (ChiCTR-TRC- 14004827) on February 19, 2014.

  6. Analgesic Effect Of Bilateral Subcostal Tap Block After Laparoscopic Cholecystectomy.

    PubMed

    Khan, Karima Karam; Khan, Robyna Irshad

    2018-01-01

    Pain after laparoscopic cholecystectomy is mild to moderate in intensity. Several modalities are employed for achieving safe and effective postoperative analgesia, the benefits of which adds to the early recovery of the patients. As a part of multimodal analgesia, various approaches of Transversus abdominis plane (TAP) block has been used for management of parietal and incisional components of pain after laparoscopic cholecystectomy. This study was designed to compare the analgesic efficacy of two different approaches of ultrasound guided TAP block, i.e., Subcostal-TAP block technique with ultrasound guided Posterior-TAP block for postoperative pain management in patients undergoing laparoscopic cholecystectomy under general anaesthesia. In this double blinded randomized controlled study, consecutive nonprobability sampling was done and a total of 126 patients admitted for elective laparoscopic cholecystectomy fulfilling the inclusion criteria were selected. After induction of general anaesthesia, patients were randomized through draw method and received either ultrasound guided posterior TAP block with 0.375% bupivacaine (20ml volume) on each side of the abdomen or subcostal TAP block bilaterally with the same. Up to 24 hours postoperatively, static and dynamic numeric rating pain scores were assessed. We found statistically significant difference in mean static pain scores over 24 hours postoperatively in subcostal TAP group, suggesting improved analgesia. However, mean dynamic postoperative pain scores were comparable between the two groups. Whereas, patients in both groups were satisfied with pain management. Ultrasound guided subcostal TAP block provides better postoperative analgesia as compared to the Posterior TAP block in laparoscopic cholecystectomy. Otherwise both of the approaches improve patient outcomes towards early recovery and discharge from hospital.

  7. Avoiding Complications in Abdominal Wall Surgery: A Mathematical Model to Predict the Course of the Motor Innervation of the Rectus Abdominis.

    PubMed

    Tessone, Ariel; Nava, Maurizio; Blondeel, Phillip; Spano, Andrea

    2016-02-01

    Ever since its introduction, the transverse rectus abdominis myocutaneous flap has become the mainstay of autologous breast reconstruction. However, concerns regarding donor site morbidity due to the breach of abdominal wall musculature integrity soon followed. Muscle-sparing techniques, eventually eliminating the muscle from the flap all-together with the deep inferior epigastric artery perforator flap, did not eliminate the problem of abdominal wall weakness. This led to the conclusion that motor innervation might be at fault. Studies have shown that even in the presence of an intact rectus abdominis muscle, and an intact anterior rectus sheath, denervation of the rectus abdominis muscle results in significant abdominal wall weakness leading to superior and inferior abdominal bulges, and abdominal herniation. Our aim was to establish a mathematical model to predict the location of the motor innervation to the rectus abdominis muscle, and thus provide surgeons with a tool that will allow them to reduce abdominal morbidity during deep inferior epigastric artery perforator and free muscle-sparing transverse rectus abdominis myocutaneous surgery. We dissected 42 cadaveric hemiabdomens and mapped the course of the thoracolumbar nerves. We then standardized and analyzed our findings and presented them as a relative map which can be adjusted to body type and dimensions. Our dissections show that the motor innervation is closely related to the lateral vascular supply. Thus, when possible, we support the preferred utilization of the medial vascular supply, and the preservation of the lateral supply and motor innervation.

  8. Change in trunk muscle activities with prone bridge exercise in patients with chronic low back pain.

    PubMed

    Kong, Yong-Soo; Park, Seol; Kweon, Mi-Gyong; Park, Ji-Won

    2016-01-01

    [Purpose] The aim of this study was to determine the effect of three different bridge exercises on internal oblique, external oblique, transverse abdominis, and erector spinae activities. [Subjects and Methods] Forty-five subjects with chronic low back pain participated in this study. The training outcome was evaluated with three different testing methods: supine bridge exercise, supine bridge on Swiss ball exercise, and prone bridge exercise. The activities of the transverse abdominis, internal oblique, external oblique, and erector spinae were measured using surface electromyography. [Results] There were significant differences in the internal oblique, external oblique, and erector spinae according to the three kinds of bridging exercises. The internal oblique, external oblique and transverse abdominis activities were highest in the prone bridge exercise, followed by those in the supine bridge on Swiss ball exercise, and supine bridge exercises. The activity of erector spine was highest in the supine bridge on Swiss ball exercise followed by the supine bridge exercise and prone bridge exercise. [Conclusion] These results suggest that prone bridge exercise is more effective than conventional supine bridge exercise and supine bridge on Swiss ball in increasing trunk muscle activity of chronic low back pain patients.

  9. Analgesic efficacy of ultrasound guided transversus abdominis plane block versus local anesthetic infiltration in adult patients undergoing single incision laparoscopic cholecystectomy: A randomized controlled trial.

    PubMed

    Bava, Ejas P; Ramachandran, Rashmi; Rewari, Vimi; Chandralekha; Bansal, Virinder Kumar; Trikha, Anjan

    2016-01-01

    Transversus abdominis plane (TAP) block has been used to provide intra- and post-operative analgesia with single incision laparoscopic (SIL) bariatric and gynecological surgery with mixed results. Its efficacy in providing analgesia for SIL cholecystectomy (SILC) via the same approach remains unexplored. The primary objective of our study was to compare the efficacy of bilateral TAP block with local anesthetic infiltration for perioperative analgesia in patients undergoing SILC. This was a prospective, randomized, controlled, double-blinded trial performed in a tertiary care hospital. Forty-two patients undergoing SILC were randomized to receive either ultrasound-guided (USG) bilateral mid-axillary TAP blocks with 0.375% ropivacaine or local anesthetic infiltration of the port site. The primary outcome measure was the requirement of morphine in the first 24 h postoperatively. The data were analyzed using t -test, Mann-Whitney test or Chi-square test. The 24 h morphine requirement (mean ± standard deviation) was 34.57 ± 14.64 mg in TAP group and 32.76 ± 14.34 mg in local infiltration group ( P = 0.688). The number of patients requiring intraoperative supplemental fentanyl in TAP group was 8 and in local infiltration group was 16 ( P = 0.028). The visual analog scale scores at rest and on coughing were significantly higher in the local infiltration group in the immediate postoperative period ( P = 0.034 and P = 0.007, respectively). USG bilateral TAP blocks were not effective in decreasing 24 h morphine requirement as compared to local anesthetic infiltration in patients undergoing SILC although it provided some analgesic benefit intraoperatively and in the initial 4 h postoperatively. Hence, the benefits of TAP blocks are not worth the effort and time spent for administering them for this surgery.

  10. Pethidine efficacy in achieving the ultrasound-guided oblique subcostal transversus abdominis plane block in laparoscopic cholecystectomy: A prospective study.

    PubMed

    Breazu, Caius Mihai; Ciobanu, Lidia; Bartos, Adrian; Bodea, Raluca; Mircea, Petru Adrian; Ionescu, Daniela

    2017-02-21

    Pethidine is a synthetic opioid with local anesthetic properties. Our goal was to evaluate the analgesic efficacy of pethidine for achieving the ultrasound-guided oblique subcostal transversus abdominis plane (OSTAP) block in laparoscopic cholecystectomy. This prospective, double-blind study included 79 patients of physical status I and II according to American Society of Anesthesiologists, scheduled for elective laparoscopic cholecystectomy. The patients were randomly allocated into three groups, depending on the drug used to achieve preoperative bilateral OSTAP block: 1) OSTAP-Placebo (treated with normal saline); 2) OSTAP-Bupivacaine (treated with 0.25% bupivacaine); and 3) OSTAP-Pethidine (treated with 1% pethidine). The efficacy of pethidine in achieving the OSTAP block was analyzed using visual analog scale (VAS), intraoperative opioid dose, opioid consumption in post anesthesia care unit, and opioid consumption in the first 24 postoperative hours. The pain scores assessed by VAS at 0, 2, 4, 6, 12, and 24 hours were significantly lower in OSTAP-Pethidine than in OSTAP-Placebo group (p < 0.001). The mean intraoperative opioid consumption was significantly lower in OSTAP-Pethidine compared to OSTAP-Placebo group (150 versus 400 mg, p < 0.001), as well as the mean opioid consumption in the first 24 hours (20.4 versus 78 mg, p < 0.001). Comparing VAS assessment between OSTAP-Bupivacaine and OSTAP-Pethidine groups, statistically significant differences were observed only for the immediate postoperative pain assessment (0 hours), where lower values were observed in OSTAP-Pethidine group (p = 0.004). There were no statistically significant differences in the incidence of postoperative nausea and vomiting (p = 0.131) between the groups. The use of 1% pethidine can be an alternative to 0.25% bupivacaine in achieving OSTAP block for laparoscopic cholecystectomy.

  11. A Comparative Study of Analgesic Efficacy of Intrathecal Buprenorphine with Ultrasound-Guided Transversus Abdominis Plane Block for Postcesarean Delivery Analgesia.

    PubMed

    Marappa, Prakash; Chikkapillappa, Manjunath Abloodu; Chennappa, Nagaraj Mungasuvalli; Pujari, Vinayak Seenappa

    2017-01-01

    Women undergoing cesarean (CS) delivery present a unique set of challenges to the anesthetist in terms of postoperative pain management. This study was conducted to compare the analgesic efficacy of intrathecal buprenorphine (ITB) with ultrasound-guided transversus abdominis plane (TAP) block in post-CS delivery pain. A prospective randomized comparative study of sixty American Society of Anesthesiologists physical status I and II pregnant patients divided into two groups of thirty each as ITB group and TAP block group after satisfying the inclusion criteria. In the present study, demographic data were comparable between both groups. The time to first analgesic request was significantly longer in ITB group (389.67 ± 90.78 min) compared to TAP group (669.17 ± 140.65 min) and was statistically significant, P < 0.001. The mean paracetamol consumption in the first 24 h was higher in the TAP group (3.5 g) compared to the ITB group (1.13 g) and was statistically significant, P < 0.0001, and the mean tramadol consumed in first 24 h was higher in the TAP (46.66 mg) group as compared to the ITB group (16.66 mg) and was statistically significant, P < 0.001. The mean visual analog scale scores assessed at 4, 6, 12, and 24 h was higher in the TAP group and was statistically significant, P < 0.001. Our study showed that patients receiving ITB for post-CS pain management reported longer duration of analgesia, lower pain scores, and lower analgesic consumption during the first 24 h. The benefits of neuraxial opiates are significant and far outweigh the side effects.

  12. [Efficiency of bupivacaine and association with dexmedetomidine in transversus abdominis plane block ultrasound guided in postoperative pain of abdominal surgery].

    PubMed

    Aksu, Recep; Patmano, Gülçin; Biçer, Cihangir; Emek, Ertan; Çoruh, Aliye Esmaoğlu

    We aimed to evaluate the effect of bupivacaine and dexmedetomidine added to bupivacaine used in tranversus abdominis plane (TAP) block on postoperative pain and patient satisfaction in patients undergoing lower abdominal surgery. Patients submitted to lower abdominal surgery were enrolled in the study. After anesthesia induction, ultrasound guided TAP block was performed. TAP block was obtained with 21mL 0.9% saline in Group C (n=31), 20mL 0.5% bupivacaine+1mL saline in Group B (n=31), and 20mL 0.5% bupivacaine+1mL dexmedetomidine (100μg) in Group BD (n=31). Visual analog scale scores were lower in Group BD compared to Group C, at all time points (p<0.05); it was lower in group BD than in group B at 10-24h. In Group B, it was lower than Group C at 2-8h (p<0.05). Total morphine consumption was lower in Group BD compared to other groups and lower in group B than in the controls (p<0.001). Patient satisfaction was higher in Group BD than in other groups and was higher in both study groups than in the controls (p<0.001). Nausea-vomiting scores, antiemetic requirement, or additional analgesic administration were not significant among groups (p>0.05). The addition of dexmedetomidine to bupivacaine on TAP block decreased postoperative pain scores and morphine consumption; it also increased patient satisfaction in patients undergoing lower abdominal surgery. Dexmedetomidine did not have any effect on nausea and vomiting score and antiemetic requirement. Copyright © 2017 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All rights reserved.

  13. Comparison of Epidural Analgesia with Transversus Abdominis Plane Analgesia for Postoperative Pain Relief in Patients Undergoing Lower Abdominal Surgery: A Prospective Randomized Study

    PubMed Central

    Iyer, Sadasivan Shankar; Bavishi, Harshit; Mohan, Chadalavada Venkataram; Kaur, Navdeep

    2017-01-01

    Background: Anesthesiologists play an important role in postoperative pain management. For analgesia after lower abdominal surgery, epidural analgesia and ultrasound-guided transversus abdominis plane (TAP) block are suitable options. The study aims to compare the analgesic efficacy of both techniques. Materials and Methods: Seventy-two patients undergoing lower abdominal surgery under spinal anesthesia were randomized to postoperatively receive lumbar epidural catheter (Group E) or ultrasound-guided TAP block (Group T) through intravenous cannulas placed bilaterally. Group E received 10 ml 0.125% bupivacaine stat and 10 ml 8th hourly for 48 h. Group T received 20 ml 0.125% bupivacaine bilaterally stat and 20 ml bilaterally 8th hourly for 48 h. Pain at rest and on coughing, total paracetamol and tramadol consumption were recorded. Results: Analgesia at rest was comparable between the groups in the first 16 h. At 24 and 48 h, Group E had significantly better analgesia at rest (P = 0.001 and 0.004 respectively). Patients in Group E had significantly higher number of patients with nil or mild pain on coughing at all times. Paracetamol consumption was comparable in both groups, but tramadol consumption was significantly higher in Group T at the end of 48 h (P = 0.001). Conclusion: For lower abdominal surgeries, analgesia provided by intermittent boluses of 0.125% is comparable for first 16 h between epidural and TAP catheters. However, the quality of analgesia provided by the epidural catheter is superior to that provided by TAP catheters beyond that both at rest and on coughing with reduced opioid consumption. PMID:28928569

  14. Imaging of Groin Pain: Magnetic Resonance and Ultrasound Imaging Features

    PubMed Central

    Lee, Susan C.; Endo, Yoshimi; Potter, Hollis G.

    2017-01-01

    Context: Evaluation of groin pain in athletes may be challenging as pain is typically poorly localized and the pubic symphyseal region comprises closely approximated tendons and muscles. As such, magnetic resonance imaging (MRI) and ultrasound (US) may help determine the etiology of groin pain. Evidence Acquisition: A PubMed search was performed using the following search terms: ultrasound, magnetic resonance imaging, sports hernia, athletic pubalgia, and groin pain. Date restrictions were not placed on the literature search. Study Design: Clinical review. Level of Evidence: Level 4. Results: MRI is sensitive in diagnosing pathology in groin pain. Not only can MRI be used to image rectus abdominis/adductor longus aponeurosis and pubic bone pathology, but it can also evaluate other pathology within the hip and pelvis. MRI is especially helpful when groin pain is poorly localized. Real-time capability makes ultrasound useful in evaluating the pubic symphyseal region, as it can be used for evaluation and treatment. Conclusion: MRI and US are valuable in diagnosing pathology in athletes with groin pain, with the added utility of treatment using US-guided intervention. Strength-of Recommendation Taxonomy: C PMID:28850315

  15. Imaging of Groin Pain: Magnetic Resonance and Ultrasound Imaging Features.

    PubMed

    Lee, Susan C; Endo, Yoshimi; Potter, Hollis G

    Evaluation of groin pain in athletes may be challenging as pain is typically poorly localized and the pubic symphyseal region comprises closely approximated tendons and muscles. As such, magnetic resonance imaging (MRI) and ultrasound (US) may help determine the etiology of groin pain. A PubMed search was performed using the following search terms: ultrasound, magnetic resonance imaging, sports hernia, athletic pubalgia, and groin pain. Date restrictions were not placed on the literature search. Clinical review. Level 4. MRI is sensitive in diagnosing pathology in groin pain. Not only can MRI be used to image rectus abdominis/adductor longus aponeurosis and pubic bone pathology, but it can also evaluate other pathology within the hip and pelvis. MRI is especially helpful when groin pain is poorly localized. Real-time capability makes ultrasound useful in evaluating the pubic symphyseal region, as it can be used for evaluation and treatment. MRI and US are valuable in diagnosing pathology in athletes with groin pain, with the added utility of treatment using US-guided intervention. Strength-of Recommendation Taxonomy: C.

  16. Perforator-Guided Drug Injection in the Treatment of Abdominal Wall Pain.

    PubMed

    Weum, Sven; de Weerd, Louis

    2016-07-01

    Pain from the abdominal wall can be caused by nerve entrapment, a condition called abdominal cutaneous nerve entrapment syndrome (ACNES). As an alternative to surgery, ACNES may be treated with injection of local anesthetics, corticosteroids, or botulinum toxin at the point of maximal pain. The point of maximal pain was marked on the abdominal skin. Using color Doppler ultrasound, the corresponding exit point of perforating blood vessels through the anterior fascia of the rectus abdominis muscle was identified. Ultrasound-guided injection of botulinum toxin in close proximity to the perforator's exit point was performed below and above the muscle fascia. The technique was used from 2008 to 2014 on 15 patients in 46 sessions with a total of 128 injections without complications. The injection technique provided safe and accurate administration of the drug in proximity to the affected cutaneous nerves. The effect of botulinum toxin on ACNES is beyond the scope of this article. Perforator-guided injection enables precise drug administration at the location of nerve entrapment in ACNES in contrast to blind injections. © 2015 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  17. Transperitoneal rectus sheath block and transversus abdominis plane block for laparoscopic inguinal hernia repair: A novel approach.

    PubMed

    Nagata, Jun; Watanabe, Jun; Nagata, Masato; Sawatsubashi, Yusuke; Akiyama, Masaki; Tajima, Takehide; Arase, Koichi; Minagawa, Noritaka; Torigoe, Takayuki; Nakayama, Yoshifumi; Horishita, Reiko; Kida, Kentaro; Hamada, Kotaro; Hirata, Keiji

    2017-08-01

    A laparoscopic approach for inguinal hernia repair is now considered the gold standard. Laparoscopic surgery is associated with a significant reduction in postoperative pain. Epidural analgesia cannot be used in patients with perioperative anticoagulant therapy because of complications such as epidural hematoma. As such, regional anesthetic techniques, such as ultrasound-guided rectus sheath block and transversus abdominis plane block, have become increasingly popular. However, even these anesthetic techniques have potential complications, such as rectus sheath hematoma, if vessels are damaged. We report the use of a transperitoneal laparoscopic approach for rectus sheath block and transversus abdominis plane block as a novel anesthetic procedure. An 81-year-old woman with direct inguinal hernia underwent laparoscopic transabdominal preperitoneal inguinal repair. Epidural anesthesia was not performed because anticoagulant therapy was administered. A Peti-needle™ was delivered through the port, and levobupivacaine was injected though the peritoneum. Surgery was performed successfully, and the anesthetic technique did not affect completion of the operative procedure. The patient was discharged without any complications. This technique was feasible, and the procedure was performed safely. Our novel analgesia technique has potential use as a standard postoperative regimen in various laparoscopic surgeries. Additional prospective studies to compare it with other techniques are required. © 2017 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and John Wiley & Sons Australia, Ltd.

  18. Ultrasound-guided rectus sheath block in children with umbilical hernia: Case series.

    PubMed

    Alsaeed, Abdul Hamid; Thallaj, Ahmed; Khalil, Nancy; Almutaq, Nada; Aljazaeri, Ayman

    2013-10-01

    Umbilical hernia repair, a common day-case surgery procedure in children, is associated with a significant postoperative pain. The most popular peripheral nerve blocks used in umbilical hernia repair are rectus sheath infiltration and caudal block. The rectus sheath block may offer improved pain relief following umbilical hernia repair with no undesired effects such as lower limb motor weakness or urinary retention seen with caudal block which might delay discharge from the hospital. Ultrasound guidance of peripheral nerve blocks has reduced the number of complications and improved the quality of blocks. The aim of this case series is to assess the post rectus sheath block pain relief in pediatric patients coming for umbilical surgery. Twenty two (22) children (age range: 1.5-8 years) scheduled for umbilical hernia repair were included in the study. Following the induction of general anesthesia, the ultrasonographic anatomy of the umbilical region was studied with a 5-16 MHz 50 mm linear probe. An ultrasound-guided posterior rectus sheath block of both rectus abdominis muscles (RMs) was performed (total of 44 punctures). An in-plain technique using Stimuplex A insulated facet tip needle 22G 50mm. Surgical conditions, intraoperative hemodynamic parameters, and postoperative analgesia by means of the modified CHEOPS scale were evaluated. ultrasonograghic visualization of the posterior sheath was possible in all patients. The ultrasound guided rectus sheath blockade provided sufficient analgesia in all children with no need for additional analgesia except for one patient who postoperatively required morphine 0.1 mg/kg intravenously. There were no complications. Ultrasound guidance enables performances of an effective rectus sheath block for umbilical hernia. Use of the Stimuplex A insulated facet tip needle 22G 50mm provides easy, less traumatic skin and rectus muscle penetration and satisfactory needle visualiza.

  19. Minimally Invasive Ultrasound-Guided Carpal Tunnel Release: Preliminary Clinical Results.

    PubMed

    Henning, P Troy; Yang, Lynda; Awan, Tariq; Lueders, Daniel; Pourcho, Adam M

    2018-04-02

    Ultrasound-guided carpal tunnel release was performed on 14 patients (18 wrists) using dynamic expansion of the transverse safe zone. Our patient population included able-bodied patients and those with impairments. The first 8 cases (12 wrists) underwent the procedure in an operating room, the remainder in an outpatient setting. No complications occurred, and all patients were able to immediately resume use of their hands without therapy. Improvements in the Quick Form of the Disabilities of the Arm, Shoulder, and Hand Index and Boston Carpal Tunnel Questionnaire at 3 months were comparable to results reported with mini-open and endoscopic release. Our results show that ultrasound-guided carpal tunnel release can be safely and effectively performed in an outpatient setting. © 2018 by the American Institute of Ultrasound in Medicine.

  20. Transversus Abdominis Plane Block versus Ilioinguinal/Iliohypogastric Nerve Block with Wound Infiltration for Postoperative Analgesia in Inguinal Hernia Surgery: A Randomized Clinical Trial.

    PubMed

    Sujatha, Chinthavali; Zachariah, Mamie; Ranjan, R V; George, Sagiev Koshy; Ramachandran, T R; Pillai, Anil Radhakrishna

    2017-01-01

    Various analgesic modalities have been used for postoperative analgesia in patients undergoing inguinal hernia surgery. In this randomized clinical trial, we have compared the analgesic efficacy of transversus abdominis plane (TAP) block with that of ilioinguinal/iliohypogastric (IIIH) nerve block with wound infiltration in patients undergoing unilateral open inguinal hernia repair. The primary objective of this study was to compare the efficacy of postoperative analgesia of ultrasound-guided TAP block and IIIH block with wound infiltration (WI) in patients undergoing open inguinal hernia surgery. This was a randomized clinical trial performed in a tertiary care hospital. Sixty patients scheduled for hernia repair were randomized into two groups, Group T and Group I. Postoperatively, under ultrasound guidance, Group T received 20 ml of 0.25% ropivacaine - TAP block and Group I received 10 ml of 0.25% ropivacaine - IIIH block + WI with 10 ml of 0.25% ropivacaine. The primary outcome measure was the time to rescue analgesia in the first 24 h postoperatively. Fentanyl along with diclofenac was given as first rescue analgesic when the patient complained of pain. Statistical comparisons were performed using Student's t -test and Chi-square test. Mean time to rescue analgesia was 5.900 ± 1.881 h and 3.766 ± 1.754 h ( P < 0.001) and the mean pain scores were 5.73 ± 0.784 and 6.03 ± 0.850 for Group TAP and IIIH + WI, respectively. Hemodynamics were stable in both the groups. One-third of the patients received one dose of paracetamol in addition to the rescue analgesic in the first 24 h. There were no complications attributed to the block. As a multimodal analgesic regimen, definitely both TAP block and IIIH block with wound infiltration have a supporting role in providing analgesia in the postoperative period for adult inguinal hernia repair. In this study, ultrasound-guided TAP block provided longer pain control postoperatively than IIIH block with WI after inguinal hernia repair. There were no complications attributed to the blocks in either of the group.

  1. Defining the reliability of sonoanatomy identification by novices in ultrasound-guided pediatric ilioinguinal and iliohypogastric nerve blockade.

    PubMed

    Ford, Simon; Dosani, Maryam; Robinson, Ashley J; Campbell, G Claire; Ansermino, J Mark; Lim, Joanne; Lauder, Gillian R

    2009-12-01

    The ilioinguinal (II)/iliohypogastric (IH) nerve block is a safe, frequently used block that has been improved in efficacy and safety by the use of ultrasound guidance. We assessed the frequency with which pediatric anesthesiologists with limited experience with ultrasound-guided regional anesthesia could correctly identify anatomical structures within the inguinal region. Our primary outcome was to compare the frequency of correct identification of the transversus abdominis (TA) muscle with the frequency of correct identification of the II/IH nerves. We used 2 ultrasound machines with different capabilities to assess a potential equipment effect on success of structure identification and time taken for structure identification. Seven pediatric anesthesiologists with <6 mo experience with ultrasound-guided regional anesthesia performed a total of 127 scans of the II region in anesthetized children. The muscle planes and the II and IH nerves were identified and labeled. The ultrasound images were reviewed by a blinded expert to mark accuracy of structure identification and time taken for identification. Two ultrasound machines (Sonosite C180plus and Micromaxx, both from Sonosite, Bothell, WA) were used. There was no difference in the frequency of correct identification of the TA muscle compared with the II/IH nerves (chi(2) test, TA versus II, P = 0.45; TA versus IH, P = 0.50). Ultrasound machine selection did show a nonsignificant trend in improving correct II/IH nerve identification (II nerve chi(2) test, P = 0.02; IH nerve chi(2) test, P = 0.04; Bonferroni corrected significance 0.17) but not for the muscle planes (chi(2) test, P = 0.83) or time taken (1-way analysis of variance, P = 0.07). A curve of improving accuracy with number of scans was plotted, with reliability of TA recognition occurring after 14-15 scans and II/IH identification after 18 scans. We have demonstrated that although there is no difference in the overall accuracy of muscle plane versus II/IH nerve identification, the muscle planes are reliably identified after fewer scans of the inguinal region. We suggest that a reliable end point for the inexperienced practitioner of ultrasound-guided II/IH nerve block may be the TA/internal oblique plane where the nerves are reported to be found in 100% of cases.

  2. Do various baseline characteristics of transversus abdominis and lumbar multifidus predict clinical outcomes in nonspecific low back pain? A systematic review.

    PubMed

    Wong, Arnold Y L; Parent, Eric C; Funabashi, Martha; Stanton, Tasha R; Kawchuk, Gregory N

    2013-12-01

    Although individual reports suggest that baseline morphometry or activity of transversus abdominis or lumbar multifidus predict clinical outcome of low back pain (LBP), a related systematic review is unavailable. Therefore, this review summarized evidence regarding the predictive value of these muscular characteristics. Candidate publications were identified from 6 electronic medical databases. After review, 5 cohort studies were included. Although this review intended to encompass studies using different muscle assessment methods, all included studies coincidentally used ultrasound imaging. No research investigated the relation between static morphometry and clinical outcomes. Evidence synthesis showed limited evidence supporting poor baseline transversus abdominis contraction thickness ratio as a treatment effect modifier favoring motor control exercise. Limited evidence supported that high baseline transversus abdominis lateral slide was associated with higher pain intensity after various exercise interventions at 1-year follow-up. However, there was limited evidence for the absence of relation between the contraction thickness ratio of transversus abdominis or anticipatory onset of lateral abdominal muscles at baseline and the short- or long-term LBP intensity after exercise interventions. There was conflicting evidence for a relation between baseline percent thickness change of lumbar multifidus during contraction and the clinical outcomes of patients after various conservative treatments. Given study heterogeneity, the small number of included studies and the inability of conventional greyscale B-mode ultrasound imaging to measure muscle activity, our findings should be interpreted with caution. Further large-scale prospective studies that use appropriate technology (ie, electromyography to assess muscle activity) should be conducted to investigate the predictive value of morphometry or activity of these muscles with respect to LBP-related outcomes measures. Copyright © 2013 International Association for the Study of Pain. Published by Elsevier B.V. All rights reserved.

  3. Dexmedetomidine decreases the required amount of bupivacaine for ultrasound-guided transversus abdominis plane block in pediatrics patients: a randomized study.

    PubMed

    Raof, Rehab Abdel; El Metainy, Shahira Ahmed; Alia, Doaa Abou; Wahab, Moataza Abdel

    2017-02-01

    The effect of dexmedetomidine on the potency of bupivacaine for transversus abdominis plane (TAP) block in pediatric patients has not been investigated. The primary objective of this study was to assess the effectiveness of dexmedetomidine to decrease the concentration of bupivacaine needed for analgesia for ultrasound-guided TAP block in a pediatric patient undergoing hernia repair or hydrocelectomy. This is a randomized, double-blind, up-down, dose-finding study. Operating room. Sixty American Society of Anesthesiologists I and II patients aged 1-4 years scheduled for elective unilateral herniorrhaphy or hydrocelectomy. Patients were randomly assigned to 1 of the 2 groups: group B (0.125% bupivacaine, 1mL/kg) TAP block or group BD (0.125% bupivacaine plus 2μg/kg dexmedetomidine, 1mL/kg) TAP block. The response of each child was observed for 60 seconds after skin incision and evaluated as 'unsuccessful' when skin incision caused a change in hemodynamic parameters (heart rate and mean blood pressure) 20% more than the preincision values. If the response was determined to be unsuccessful, the concentration of bupivacaine administrated to the next patient was increased by 0.02%. If it was successful, the concentration of bupivacaine administrated to the next patient was decreased by 0.02%. The minimum local anesthetic concentration of bupivacaine was 0.0839% (0.0137) in the B group and 0.0550% (0.0169) in the BD group. The difference was statistically significant (t=7.165, P=.0001). The total postoperative analgesic dosage of morphine was significantly higher in the B group (0.17±0.04 mg/kg) than the BD group (0.11±0.02 mg/kg, P=.001). The addition of 2μg/kg of dexmedetomidine reduced the minimum local anesthetic concentration of bupivacaine used for a TAP block and improved postoperative analgesia in children undergoing surgery for inguinal hernia repair or hydrocelectomy. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Analgesic efficacy of ultrasound guided transversus abdominis plane block versus local anesthetic infiltration in adult patients undergoing single incision laparoscopic cholecystectomy: A randomized controlled trial

    PubMed Central

    Bava, Ejas P.; Ramachandran, Rashmi; Rewari, Vimi; Chandralekha; Bansal, Virinder Kumar; Trikha, Anjan

    2016-01-01

    Background: Transversus abdominis plane (TAP) block has been used to provide intra- and post-operative analgesia with single incision laparoscopic (SIL) bariatric and gynecological surgery with mixed results. Its efficacy in providing analgesia for SIL cholecystectomy (SILC) via the same approach remains unexplored. Aims: The primary objective of our study was to compare the efficacy of bilateral TAP block with local anesthetic infiltration for perioperative analgesia in patients undergoing SILC. Settings and Design: This was a prospective, randomized, controlled, double-blinded trial performed in a tertiary care hospital. Materials and Methods: Forty-two patients undergoing SILC were randomized to receive either ultrasound-guided (USG) bilateral mid-axillary TAP blocks with 0.375% ropivacaine or local anesthetic infiltration of the port site. The primary outcome measure was the requirement of morphine in the first 24 h postoperatively. Statistical Analysis: The data were analyzed using t-test, Mann–Whitney test or Chi-square test. Results: The 24 h morphine requirement (mean ± standard deviation) was 34.57 ± 14.64 mg in TAP group and 32.76 ± 14.34 mg in local infiltration group (P = 0.688). The number of patients requiring intraoperative supplemental fentanyl in TAP group was 8 and in local infiltration group was 16 (P = 0.028). The visual analog scale scores at rest and on coughing were significantly higher in the local infiltration group in the immediate postoperative period (P = 0.034 and P = 0.007, respectively). Conclusion: USG bilateral TAP blocks were not effective in decreasing 24 h morphine requirement as compared to local anesthetic infiltration in patients undergoing SILC although it provided some analgesic benefit intraoperatively and in the initial 4 h postoperatively. Hence, the benefits of TAP blocks are not worth the effort and time spent for administering them for this surgery. PMID:27746552

  5. A reevaluation of the unusual abdominal musculature of squamate reptiles (Reptilia: Squamata).

    PubMed

    Bhullar, Bhart-Anjan S

    2009-08-01

    The abdominal muscles of lizards and snakes (Squamata) have been the subject of periodic attention from anatomists, embryologists, and systematists. Until now, the presence of a superficial portion of the m. rectus abdominis, named the m. rectus abdominis lateralis, has been considered a key synapomorphy of the clade Autarchoglossa, which includes all extant squamates save Gekkota and Iguania. However, the precise anatomical relations of the m. rectus abdominis lateralis have never been fully investigated. Here, I show that the m. rectus abdominis lateralis is present in Iguania. Its absence in Gekkota represents rare gross anatomical support for recent molecular-structure-based hypotheses of squamate relationships placing geckoes as sister to the remaining squamates. Where present, it is the most superficial trunk muscle, exterior to the m. obliquus externus. The separation of the m. rectus abdominis lateralis from the m. rectus abdominis occurs as the m. obliquus externus aponeurosis and part of the m. obliquus internus aponeurosis emerge superficially to form the outer portion of the rectus sheath. In Autarchoglossa, the contralateral mm. recti abdomines laterales meet at the midline and are attached to the imbricae of the transverse scale rows characteristic of the clade, suggesting developmental, functional, and evolutionary association. Because the m. rectus abdominis lateralis is sometimes continuous with the pectoralis, its exclusive association with the m. rectus abdominis is questionable. It may be a neomorphic layer that is part of the abaxial developmental system, comprising those muscles whose connective tissue is largely derived from lateral plate as opposed to somatic mesoderm. (c) 2009 Wiley-Liss, Inc.

  6. Verification of an optimized stimulation point on the abdominal wall for transcutaneous neuromuscular electrical stimulation for activation of deep lumbar stabilizing muscles.

    PubMed

    Baek, Seung Ok; Cho, Hee Kyung; Jung, Gil Su; Son, Su Min; Cho, Yun Woo; Ahn, Sang Ho

    2014-09-01

    Transcutaneous neuromuscular electrical stimulation (NMES) can stimulate contractions in deep lumbar stabilizing muscles. An optimal protocol has not been devised for the activation of these muscles by NMES, and information is lacking regarding an optimal stimulation point on the abdominal wall. The goal was to determine a single optimized stimulation point on the abdominal wall for transcutaneous NMES for the activation of deep lumbar stabilizing muscles. Ultrasound images of the spinal stabilizing muscles were captured during NMES at three sites on the lateral abdominal wall. After an optimal location for the placement of the electrodes was determined, changes in the thickness of the lumbar multifidus (LM) were measured during NMES. Three stimulation points were investigated using 20 healthy physically active male volunteers. A reference point R, 1 cm superior to the iliac crest along the midaxillary line, was used. Three study points were used: stimulation point S1 was located 2 cm superior and 2 cm medial to the anterior superior iliac spine, stimulation point S3 was 2 cm below the lowest rib along the same sagittal plane as S1, and stimulation point S2 was midway between S1 and S3. Sessions were conducted stimulating at S1, S2, or S3 using R for reference. Real-time ultrasound imaging (RUSI) of the abdominal muscles was captured during each stimulation session. In addition, RUSI images were captured of the LM during stimulation at S1. Thickness, as measured by RUSI, of the transverse abdominis (TrA), obliquus internus, and obliquus externus was greater during NMES than at rest for all three study points (p<.05). Transverse abdominis was significantly stimulated more by NMES at S1 than at the other points (p<.05). The LM thickness was also significantly greater during NMES at S1 than at rest (p<.05). Neuromuscular electrical stimulation at S1 optimally activated deep spinal stabilizing muscles, TrA and LM, as evidenced by RUSI. The authors recommend this optimal stimulation point be used for NMES in the course of lumbar spine stabilization training in patients having difficulty initiating contraction of these muscles. Copyright © 2014 Elsevier Inc. All rights reserved.

  7. Reliability of real-time ultrasound for the assessment of transversus abdominis function.

    PubMed

    Kidd, Adrian W; Magee, Scott; Richardson, Carolyn A

    2002-07-01

    Transversus abdominis (TrA) has now been established as a key muscle for the stabilization of the lumbar spine and sacroiliac joints. Significantly, dysfunction of this muscle has also been implicated in low back pain. Real-time ultrasound (US) is a non-invasive procedure that has the potential to evaluate objectively the function of TrA. To investigate M-mode US as a reliable method of assessing TrA function. M-mode US was used to measure the width of TrA as subjects drew in their lower abdominal wall at a controlled speed to a target depth. Eleven subjects were imaged. the measures of TrA width were reliable and ranged between 3.14mm relaxed and 6.35mm contracted. The standard error of measurement ranged between 0.18mm and 0.57mm. M-mode US provides a reliable non-invasive measure of a controlled contraction of TrA.

  8. Short beveled sharp cutting needle is superior to facet tip needle for ultrasound-guided rectus sheath block in children with umbilical hernia: a case series.

    PubMed

    Alsaeed, A; Thallaj, A; Alzahrani, T; Khalil, N; Aljazaeri, A

    2014-10-01

    The most common peripheral nerve blocks used in umbilical hernia repair are rectus sheath block and regional block (caudal block). Ultrasound guidance of peripheral nerve blocks has reduced the number of complications and improved the quality of blocks. The aim of this study is to assess the post rectus sheath block pain relief in pediatric patients coming for umbilical surgery, and to evaluate the easiness of soft tissue puncture and ultrasonic appearance of two different needle types. Twenty two (22) pediatric patients (age range: 1.5-8 years) scheduled for umbilical hernia repair were included in the study. Following the induction of general anesthesia, the ultrasonographic anatomy of the umbilical region was studied with a 5-16 MHz linear probe. An ultrasound-guided rectus sheath block in the lateral edge of both rectus abdominis muscles (RMs) was performed (total of 44 punctures). A 22 gauge short beveled sharp cutting needle 1.1 x 30 mm needle A (BD Insyte--W, Vialon material. Spain) was used in one side, and a Stimuplex A insulated Needle 22G 50mm (needle B) was used on the other side. Surgical conditions, intraoperative hemodynamic parameters, and postoperative analgesia were evaluated. Ultrasonograghic visualization of the posterior sheath was possible in all patients. Needle A scored 72.7% of excellent needle tip and shaft view (16 out of 22) compared to 63.63% for needle B (14 out of 22). None of the needles scored poor view. The ultrasound guided rectus sheath blockade provided sufficient analgesia in all children with no need for additional analgesia except for one child who postoperatively requested morphine 0.1 mg/kg intravenously in recovery room. There were no complications. Ultrasound guidance enables performances of an effective rectus sheath block for umbilical hernia in the lateral edge of the rectus muscle. Use of the sharp short beveled needle of 22 gauge intravenous (IV) cannula stylet provides easy, less traumatic skin and rectus muscle penetration and better needle visualization by the ultrasound.

  9. The use of ultrasound imaging of the abdominal drawing-in maneuver in subjects with low back pain.

    PubMed

    Teyhen, Deydre S; Miltenberger, Chad E; Deiters, Henry M; Del Toro, Yadira M; Pulliam, Jennifer N; Childs, John D; Boyles, Robert E; Flynn, Timothy W

    2005-06-01

    Randomized controlled trial among patients with low back pain (LBP). (1) Determine the reliability of real-time ultrasound imaging for assessing activation of the lateral abdominal muscles; (2) characterize the extent to which the abdominal drawing-in maneuver (ADIM) results in preferential activation of the transverse abdominis (TrA); and (3) determine if ultrasound biofeedback improves short-term performance of the ADIM in patients with LBP. Ultrasound imaging is reportedly useful for measuring and training patients to preferentially activate the TrA muscle. However, research to support these claims is limited. Thirty patients with LBP referred for lumbar stabilization training were randomized to receive either traditional training (n = 15) or traditional training with biofeedback (n = 15). Ultrasound imaging was used to measure changes in thickness of the lateral abdominal muscles. Differences in preferential changes in muscle thickness of the TrA between groups and across time were assessed using analysis of variance. Intrarater reliability measuring lateral abdominal muscle thickness exceeded 0.93. On average, patients in both groups demonstrated a 2-fold increase in the thickness of the TrA during the ADIM. Performance of the ADIM did not differ between the groups. These data provide construct validity for the notion that the ADIM results in preferential activation of the TrA in patients with LBP. Although, the addition of biofeedback did not enhance the ability to perform the ADIM at a short-term follow-up, our data suggest a possible ceiling effect or an insufficient training stimulus. Further research is necessary to determine if there is a subgroup of patients with LBP who may benefit from biofeedback.

  10. Cutaneous Sensory Block Area, Muscle-Relaxing Effect, and Block Duration of the Transversus Abdominis Plane Block: A Randomized, Blinded, and Placebo-Controlled Study in Healthy Volunteers.

    PubMed

    Støving, Kion; Rothe, Christian; Rosenstock, Charlotte V; Aasvang, Eske K; Lundstrøm, Lars H; Lange, Kai H W

    2015-01-01

    The transversus abdominis plane (TAP) block is a widely used nerve block. However, basic block characteristics are poorly described. The purpose of this study was to assess the cutaneous sensory block area, muscle-relaxing effect, and block duration. Sixteen healthy volunteers were randomized to receive an ultrasound-guided unilateral TAP block with 20 mL 7.5 mg/mL ropivacaine and placebo on the contralateral side. Measurements were performed at baseline and 90 minutes after performing the block. Cutaneous sensory block area was mapped and separated into a medial and lateral part by a vertical line through the anterior superior iliac spine. We measured muscle thickness of the 3 lateral abdominal muscle layers with ultrasound in the relaxed state and during maximal voluntary muscle contraction. The volunteers reported the duration of the sensory block and the abdominal muscle-relaxing effect. The lateral part of the cutaneous sensory block area was a median of 266 cm2 (interquartile range, 191-310 cm2) and the medial part 76 cm 2(interquartile range, 54-127 cm2). In all the volunteers, lateral wall muscle thickness decreased significantly by 9.2 mm (6.9-15.7 mm) during a maximal contraction. Sensory block and muscle-relaxing effect duration were 570 minutes (512-716 minutes) and 609 minutes (490-724 minutes), respectively. Cutaneous sensory block area of the TAP block is predominantly located lateral to a vertical line through the anterior superior iliac spine. The distribution is nondermatomal and does not cross the midline. The muscle-relaxing effect is significant and consistent. The block duration is approximately 10 hours with large variation.

  11. Development of a spherically focused phased array transducer for ultrasonic image-guided hyperthermia

    PubMed Central

    Liu, Jingfei; Foiret, Josquin; Stephens, Douglas N.; Le Baron, Olivier; Ferrara, Katherine W.

    2016-01-01

    A 1.5 MHz prolate spheroidal therapeutic array with 128 circular elements was designed to accommodate standard imaging arrays for ultrasonic image-guided hyperthermia. The implementation of this dual-array system integrates real-time therapeutic and imaging functions with a single ultrasound system (Vantage 256, Verasonics). To facilitate applications involving small animal imaging and therapy the array was designed to have a beam depth of field smaller than 3.5 mm and to electronically steer over distances greater than 1 cm in both the axial and lateral directions. In order to achieve the required f number of 0.69, 1-3 piezocomposite modules were mated within the transducer housing. The performance of the prototype array was experimentally evaluated with excellent agreement with numerical simulation. A focal volume (2.70 mm (axial) × 0.65 mm (transverse) × 0.35 mm (transverse)) defined by the −6 dB focal intensity was obtained to address the dimensions needed for small animal therapy. An electronic beam steering range defined by the −3 dB focal peak intensity (17 mm (axial) × 14 mm (transverse) × 12 mm (transverse)) and −8 dB lateral grating lobes (24 mm (axial) × 18 mm (transverse) × 16 mm (transverse)) was achieved. The combined testing of imaging and therapeutic functions confirmed well-controlled local heating generation and imaging in a tissue mimicking phantom. This dual-array implementation offers a practical means to achieve hyperthermia and ablation in small animal models and can be incorporated within protocols for ultrasound-mediated drug delivery. PMID:27353347

  12. The effects of prone bridge exercise on trunk muscle thickness in chronic low back pain patients.

    PubMed

    Kong, Yong-Soo; Lee, Woo-Jin; Park, Seol; Jang, Gwon-Uk

    2015-07-01

    [Purpose] This study aimed to investigate the effects of prone bridge exercise on trunk muscle thickness. [Subjects and Methods] Thirty-seven chronic low back pain patients participated in this study. Each participant was randomly assigned to one of three exercise groups, namely, a prone bridge exercise group, supine bridge exercise on a Swiss ball group, and supine bridge exercise group. The thicknesses of the transverse abdominis (TrA), internal oblique (IO), and external oblique (EO) were measured using ultrasound. [Results] After eight weeks of training, the three groups showed significant increases in the thicknesses of the TrA, IO, and EO. Among the groups, TrA and IO showed significantly different muscle thicknesses. [Conclusion] The prone bridge exercise significantly affected the thicknesses of the TrA, IO, and EO unlike the supine bridge exercises. Based on the results of this study, the prone bridge exercise is a more effective method to improve trunk stability than conventional supine bridge exercises.

  13. Donor-Site Complications and Remnant of Rectus Abdominis Muscle Status after Transverse Rectus Abdominis Myocutaneous Flap Reconstruction

    PubMed Central

    Chirappapha, Prakasit; Trikunagonvong, Noppadol; Rongthong, Sasiprapa; Lertsithichai, Panuwat; Sukarayothin, Thongchai; Leesombatpaiboon, Monchai; Panawattanakul, Rujira; Thaweepworadej, Panya

    2017-01-01

    Background: Transverse rectus abdominis myocutaneous (TRAM) flap reconstruction after mastectomy in breast cancer patients has become one of the milestones in breast reconstruction. There are several techniques that have been used in an attempt to minimize untoward complications. We present the whole muscle with partial sheath-sparing technique that focuses on the anatomy of arcuate line and the closure of the anterior abdominal wall techniques with mesh and determine factors associated with its complications and outcomes. Methods: We retrospectively and prospectively review the results of 30 pedicled TRAM flaps that were performed between November 2013 and March 2016, focusing on outcomes and complications. Results: Among the 30 pedicled TRAM flap procedures in 30 patients, there were complications in 5 patients (17%). Most common complications were surgical-site infection (7%). After a median follow-up time of 15 months, no patient developed abdominal wall hernia or bulging in daily activities in our study, but 6 patients (20%) had asymptomatic abdominal wall bulging when exercised. Significant factors related to asymptomatic exercised abdominal wall bulging included having a body mass index of more than 23 kg/m2. Conclusion: Pedicled TRAM flap by using the technique of the whole muscle with partial sheath-sparing technique combined with reinforcement above the arcuate line with mesh can reduce the occurrence of abdominal bulging and hernia. PMID:28740793

  14. Effects of age and inactivity due to prolonged bed rest on atrophy of trunk muscles.

    PubMed

    Ikezoe, Tome; Mori, Natsuko; Nakamura, Masatoshi; Ichihashi, Noriaki

    2012-01-01

    This study investigated the effects of age and inactivity due to being chronically bedridden on atrophy of trunk muscles. The subjects comprised 33 young women (young group) and 41 elderly women who resided in nursing homes or chronic care institutions. The elderly subjects were divided into two groups: independent elderly group who were able to perform activities of daily living involving walking independently (n = 28) and dependent elderly group who were chronically bedridden (n = 13). The thickness of the following six trunk muscles was measured by B-mode ultrasound: the rectus abdominis, external oblique, internal oblique, transversus abdominis, thoracic erector spinae (longissimus) and lumbar multifidus muscles. All muscles except for the transversus abdominis and lumbar multifidus muscles were significantly thinner in the independent elderly group compared with those in the young group. The thicknesses of all muscles in the dependent elderly group was significantly smaller than that in the young group, whereas there were no differences between the dependent elderly and independent elderly groups in the muscle thicknesses of the rectus abdominis and internal oblique muscles. In conclusion, our results suggest that: (1) age-related atrophy compared with young women was less in the deep antigravity trunk muscles than the superficial muscles in the independent elderly women; (2) atrophy associated with chronic bed rest was more marked in the antigravity muscles, such as the back and transversus abdominis.

  15. Development of a spherically focused phased array transducer for ultrasonic image-guided hyperthermia

    NASA Astrophysics Data System (ADS)

    Liu, Jingfei; Foiret, Josquin; Stephens, Douglas N.; Le Baron, Olivier; Ferrara, Katherine W.

    2016-07-01

    A 1.5 MHz prolate spheroidal therapeutic array with 128 circular elements was designed to accommodate standard imaging arrays for ultrasonic image-guided hyperthermia. The implementation of this dual-array system integrates real-time therapeutic and imaging functions with a single ultrasound system (Vantage 256, Verasonics). To facilitate applications involving small animal imaging and therapy the array was designed to have a beam depth of field smaller than 3.5 mm and to electronically steer over distances greater than 1 cm in both the axial and lateral directions. In order to achieve the required f number of 0.69, 1-3 piezocomposite modules were mated within the transducer housing. The performance of the prototype array was experimentally evaluated with excellent agreement with numerical simulation. A focal volume (2.70 mm (axial)  ×  0.65 mm (transverse)  ×  0.35 mm (transverse)) defined by the  -6 dB focal intensity was obtained to address the dimensions needed for small animal therapy. An electronic beam steering range defined by the  -3 dB focal peak intensity (17 mm (axial)  ×  14 mm (transverse)  ×  12 mm (transverse)) and  -8 dB lateral grating lobes (24 mm (axial)  ×  18 mm (transverse)  ×  16 mm (transverse)) was achieved. The combined testing of imaging and therapeutic functions confirmed well-controlled local heating generation and imaging in a tissue mimicking phantom. This dual-array implementation offers a practical means to achieve hyperthermia and ablation in small animal models and can be incorporated within protocols for ultrasound-mediated drug delivery.

  16. Development of a spherically focused phased array transducer for ultrasonic image-guided hyperthermia.

    PubMed

    Liu, Jingfei; Foiret, Josquin; Stephens, Douglas N; Le Baron, Olivier; Ferrara, Katherine W

    2016-07-21

    A 1.5 MHz prolate spheroidal therapeutic array with 128 circular elements was designed to accommodate standard imaging arrays for ultrasonic image-guided hyperthermia. The implementation of this dual-array system integrates real-time therapeutic and imaging functions with a single ultrasound system (Vantage 256, Verasonics). To facilitate applications involving small animal imaging and therapy the array was designed to have a beam depth of field smaller than 3.5 mm and to electronically steer over distances greater than 1 cm in both the axial and lateral directions. In order to achieve the required f number of 0.69, 1-3 piezocomposite modules were mated within the transducer housing. The performance of the prototype array was experimentally evaluated with excellent agreement with numerical simulation. A focal volume (2.70 mm (axial)  ×  0.65 mm (transverse)  ×  0.35 mm (transverse)) defined by the  -6 dB focal intensity was obtained to address the dimensions needed for small animal therapy. An electronic beam steering range defined by the  -3 dB focal peak intensity (17 mm (axial)  ×  14 mm (transverse)  ×  12 mm (transverse)) and  -8 dB lateral grating lobes (24 mm (axial)  ×  18 mm (transverse)  ×  16 mm (transverse)) was achieved. The combined testing of imaging and therapeutic functions confirmed well-controlled local heating generation and imaging in a tissue mimicking phantom. This dual-array implementation offers a practical means to achieve hyperthermia and ablation in small animal models and can be incorporated within protocols for ultrasound-mediated drug delivery.

  17. A pilot study on the influence of exercising on unstable training machine on balance control and trunk muscles activity.

    PubMed

    Domeika, Aurelijus; Aleknaite-Dambrauskiene, Ieva; Poskaitis, Vytautas; Zaveckas, Vidmantas; Grigas, Vytautas; Zvironiene, Ausra

    2018-05-16

    The main position of the working population is becoming sitting. Immobile prolonged sedentary time may cause negative effects including reduced intervertebral discs nutrition. Main ways of mitigating them are regular position changes and exercising. To evaluate influence of the short term training on unstable training machine on balance control and trunk muscles activity in patients with lower back pain. Participants (n=16) experiencing lower back pain were trained on an unstable sculling machine "Rehabili". Their balance tested by (Biodex Balance System) and rectus abdominis, externus oblique, transverse abdominis, multifidus and erector spine muscles activity (measured by surface electromyography) while sitting and standing with usual and aligned body postures both before and after six weeks of training (three 15 minutes sessions per week) were compared in between. Balance control improved after the training program. Besides, more symmetrical activation of both sides rectus and transversus abdominis muscles, as well as increased transversus abdominis muscle activation of 19% (p< 0.05), were observed. Six weeks short sessions training on unstable training machine improved balance control and increased trunk muscles activity especially in aligned body posture when standing or sitting on unstable surface.

  18. Ultrasound-guided Combined Fascial Plane Blocks as an Intervention for Pain Management after Laparoscopic Cholecystectomy: A Randomized Control Study

    PubMed Central

    Ramkiran, Seshadri; Jacob, Mathews; Honwad, Manish; Vivekanand, Desiraju; Krishnakumar, Mathangi; Patrikar, Seema

    2018-01-01

    Background: Pain associated with laparoscopic cholecystectomy is most severe during the first 24 h and the port sites are the most painful. Recent multimodal approaches target incisional pain instead of visceral pain which has led to the emergence of abdominal fascial plane blocks. This study embraces a novel combination of two independently effective fascial plane blocks, namely rectus sheath block and subcostal transversus abdominis plane (TAP) block to alleviate postoperative pain. Study Objective: The aim is to evaluate the effectiveness of the combination of rectus sheath block and subcostal TAP block, to compare its efficacy with that of subcostal TAP block alone and with conventional port site infiltration (PSI) in alleviating postoperative pain in patients undergoing laparoscopic cholecystectomy. Methodology: This prospective, randomized control, pilot study included 61 patients scheduled for elective laparoscopic cholecystectomy and distributed among three groups, namely Group 1: Combined subcostal TAP block with rectus sheath block (n = 20); Group 2: Oblique subcostal TAP block alone (n = 21); and Group 3: PSI group as an active control (n = 20). Results: Combined group had significantly lower pain scores, higher satisfaction scores, and reduced rescue analgesia both in early and late postoperative periods than the conventional PSI group. Conclusion: Ultrasound-guided combined fascial plane blocks is a novel intervention in pain management of patients undergoing laparoscopic cholecystectomy and should become the standard of care. PMID:29628547

  19. Ultrasound-guided transversus abdominis plane block for postoperative analgesia in living liver donors: A prospective, randomized, double-blinded clinical trial.

    PubMed

    Kıtlık, Arzu; Erdogan, Mehmet Ali; Ozgul, Ulku; Aydogan, Mustafa Said; Ucar, Muharrem; Toprak, Huseyin Ilksen; Colak, Cemil; Durmus, Mahmut

    2017-02-01

    Transversus abdominis plane (TAP) block is a peripheral nerve block that reduces postoperative pain, nausea, vomiting and the need for postoperative opioids following various types of abdominal surgery. The primary aim of the present study was to evaluate the effects of TAP block on postoperative analgesia and opioid consumption in living liver donors in whom a right "J" abdominal incision was used. This prospective, double-blinded, randomized controlled study was conducted with 50 living liver donors, aged 18-65years, who were scheduled to undergo right hepatectomy. Patients who received ultrasonography-guided subcostal TAP block were allocated into Group 1, and patients who did not receive TAP block were allocated into Group 2. The TAP blocks were performed bilaterally at the conclusion of surgery using 1.5mg∗kg -1 bupivacaine diluted with saline to reach a total volume of 40mL. For each patient, morphine consumption, pain scores at rest and movement, sedation scores, nausea, vomiting and the need for antiemetic medication were assessed at 0, 2, 4, 6, 12 and 24h postoperatively by researchers who were blinded to the study groups. Morphine consumption was significantly lower in Group 1 than in Group 2 at the 2nd, 6th and 24th hours (P<0.05). The mean total morphine consumption values after 24h were 40mg and 65mg in Groups 1 and 2, respectively. The TAP block significantly reduced postoperative visual analog scale pain scores both at rest and during movement at 0, 2, 4, 6, and 24h postoperatively (P<0.05). The TAP block reduced 24-h postoperative morphine consumption and contributed to analgesia in living liver donors who underwent upper abdominal wall incisions. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. A randomized trial comparing surgeon-administered intraoperative transversus abdominis plane block with anesthesiologist-administered transcutaneous block.

    PubMed

    Narasimhulu, D M; Scharfman, L; Minkoff, H; George, B; Homel, P; Tyagaraj, K

    2018-04-27

    Injection of local anesthetic into the transversus abdominis plane (TAP block) decreases systemic morphine requirements after abdominal surgery. We compared intraoperative surgeon-administered TAP block (surgical TAP) to anesthesiologist-administered transcutaneous ultrasound-guided TAP block (conventional TAP) for post-cesarean analgesia. We hypothesized that surgical TAP blocks would take less time to perform than conventional TAP blocks. We performed a randomized trial, recruiting 41 women undergoing cesarean delivery under neuraxial anesthesia, assigning them to either surgical TAP block (n=20) or conventional TAP block (n=21). Time taken to perform the block was the primary outcome, while postoperative pain scores and 24-hour opioid requirements were secondary outcomes. Student's t-test was used to compare block time and Kruskal-Wallis test opioid consumption and pain-scores. Time taken to perform the block (2.4 vs 12.1 min, P <0.001), and time spent in the operating room after delivery (55.3 vs 77.9 min, P <0.001) were significantly less for surgical TAP. The 24 h morphine consumption (P=0.17) and postoperative pain scores at 4, 8, 24 and 48 h were not significantly different between the groups. Surgical TAP blocks are feasible and less time consuming than conventional TAP blocks, while providing comparable analgesia after cesarean delivery. Copyright © 2018 Elsevier Ltd. All rights reserved.

  1. Measurement methods to assess diastasis of the rectus abdominis muscle (DRAM): A systematic review of their measurement properties and meta-analytic reliability generalisation.

    PubMed

    van de Water, A T M; Benjamin, D R

    2016-02-01

    Systematic literature review. Diastasis of the rectus abdominis muscle (DRAM) has been linked with low back pain, abdominal and pelvic dysfunction. Measurement is used to either screen or to monitor DRAM width. Determining which methods are suitable for screening and monitoring DRAM is of clinical value. To identify the best methods to screen for DRAM presence and monitor DRAM width. AMED, Embase, Medline, PubMed and CINAHL databases were searched for measurement property studies of DRAM measurement methods. Population characteristics, measurement methods/procedures and measurement information were extracted from included studies. Quality of all studies was evaluated using 'quality rating criteria'. When possible, reliability generalisation was conducted to provide combined reliability estimations. Thirteen studies evaluated measurement properties of the 'finger width'-method, tape measure, calipers, ultrasound, CT and MRI. Ultrasound was most evaluated. Methodological quality of these studies varied widely. Pearson's correlations of r = 0.66-0.79 were found between calipers and ultrasound measurements. Calipers and ultrasound had Intraclass Correlation Coefficients (ICC) of 0.78-0.97 for test-retest, inter- and intra-rater reliability. The 'finger width'-method had weighted Kappa's of 0.73-0.77 for test-retest reliability, but moderate agreement (63%; weighted Kappa = 0.53) between raters. Comparing calipers and ultrasound, low measurement error was found (above the umbilicus), and the methods had good agreement (83%; weighted Kappa = 0.66) for discriminative purposes. The available information support ultrasound and calipers as adequate methods to assess DRAM. For other methods limited measurement information of low to moderate quality is available and further evaluation of their measurement properties is required. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. [Radical hysterectomy in a patient with Steinert disease: spinal anaesthesia, ketamine and TAP and rectus sheath blocks].

    PubMed

    Armendáriz-Buil, I; Marenco-Arellano, V

    2015-01-01

    The case of a patient with Steinert disease who underwent surgery for radical hysterectomy is presented. Because of her advanced disease, she suffered from chronic respiratory failure which required non-invasive ventilation (NIV) at night. Spinal anaesthesia was chosen as an anaesthetic treatment. At the time of aortic lymphadenectomy, the patient reported moderate pain at hypogastrium, which was well controlled with boluses of 10 mg of ketamine. Postoperatively, opioid administration was avoided by applying abdominal wall blocks: transverse abdominis plane (TAP) block and sheath of rectus abdominis muscle block. The evolution of the patient was satisfactory and she was discharged on the fifth day after surgery.

  3. Ultrasound-Guided Carpal Tunnel Release Using Dynamic Expansion of the Transverse Safe Zone in a Patient With Postpolio Syndrome: A Case Report.

    PubMed

    Henning, Troy; Lueders, Daniel; Chang, Kate; Yang, Lynda

    2018-03-06

    The prevalence of carpal tunnel syndrome (CTS) in patients with postpolio syndrome occurs at a rate of 22%. Irrespective of those with CTS, 74% of postpolio patients weight bear through their arms for ambulation or transfers. As open carpal tunnel release is performed along the weight-bearing region of the wrist, their functional independence may be altered while recovering. This case demonstrates that ultrasound-guided carpal tunnel release was successfully performed in a patient with postpolio syndrome allowing him to immediately weight bear through his hands after the procedure so he could recover at home. Copyright © 2018 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  4. Can activity within the external abdominal oblique be measured using real-time ultrasound imaging?

    PubMed

    John, E K; Beith, I D

    2007-11-01

    Differences in the function of the anterolateral abdominal muscles have been the subject of much investigation, but primarily using electromyography. Recently changes in thickness of transversus abdominis and internal oblique measured from real-time ultrasound images have been shown to represent activity within these muscles. However it is still unclear if such a change in thickness in external oblique similarly represents activity within that muscle. The purpose of this study was to investigate the relationship between change in thickness and muscle activity in the external oblique using real-time ultrasound and surface electromyography. Simultaneous measurements of electromyography and real-time ultrasound images of external oblique were studied in up to 24 subjects during two tasks compared to the muscle at rest (1) isometric trunk rotation and (2) drawing in the lower abdomen. Changes in muscle thickness correlated significantly with electromyography during isometric trunk rotation in the majority of subjects but with a significant difference between subjects. In contrast, the relationship between change in thickness and electrical activity in the muscle when drawing in the lower abdomen was significant in less than 50% of subjects and the muscle often got thinner. Thickness changes of external oblique can be used as a valid indicator of electromyography activity during isometric trunk rotation, though the relationship is not as good as previously published data for transversus abdominis. Thickness changes of external oblique measured during lower abdominal drawing in cannot be used to detect activity within this muscle.

  5. A technical report on ultrasound-guided scapulocostal syndrome injection.

    PubMed

    McCarthy, C; Harmon, D

    2016-08-01

    We describe a case report and technique for using an ultrasound scanner and a linear transducer to guide serratus posterior superior (SPS) muscle injection. A 43-year-old female presented with chronic pain centered under the right upper portion of her scapula impacting her activities of daily living. For the ultrasound-guided SPS muscle injection, the patient was placed in the prone position. The transducer was oriented in a transverse orientation at the level of the C6-T1 vertebrae. Here the SPS muscle attaches to the lower portion of the ligament nuchae and the intervening interspinous ligaments. The muscle fibers run inferiorly and laterally to attach to the 2nd-5th ribs which were identified along with the lateral portion of the serratus posterior superior muscle which is covered by the scapula. Real-time imaging was used to direct a spinal needle into the trigger points of the SPS muscle, where solution was injected under direct vision. The patient's pain symptoms improved significantly. Serratus posterior superior injection can confirm a diagnosis of scapulocostal syndrome and be therapeutically beneficial.

  6. [Imaging features of pubalgia].

    PubMed

    Sans, N; Lhoste-Trouilloud, A; Sethom, S; Camara, P-Y; Jirari, M; Ponsot, A; Railhac, J-J

    2011-06-01

    Pubalgia is a generic term used to describe groin pain due to a multitude of different etiologies such as skeletal (microtraumatic pubic symphysis arthropathy), muscular (adductor or rectus abdominis disorders), or abdominal wall (inguinal hernia) disorders. Diagnosis relies mainly on MRI for musculoskeletal disorders and ultrasound for abdominal wall disorders. Copyright © 2011. Published by Elsevier Masson SAS.

  7. [Feasibility and accuracy of ultrasound-guided methodology in the examination of lumbar spine facet joints].

    PubMed

    Wen, Chuan-Bing; Li, Yong-Zhong; Tang, Qin-Qin; Sun, Lin; Xiao, Hong; Yang, Bang-Xiang; Song, Li; Liu, Hui

    2013-03-01

    To investigate the feasibility, accuracy of B ultrasound in the examination of joint space of lumbar spine facet joints compared with CT scan. Ten healthy adult volunteers were enrolled. The joint space of lumbar facet joints was measured by ultrasound. To identify the spinal levels, the posterior parasagittal sonograms were obtained at levels L1 to S1. The lumbar facet joints were delineated with the help of transverse sonograms at each level. Meanwhile, the lumbar facet joints were evaluated by spiral CT on the same plane, reformatted to 1-mm axial slices. A total of 88 lumbar facet joints from L1 to S1 were clearly visualized in the 10 volunteers. Both ultrasound and CT measurements showed the same average depth and lateral distance of lumbar facet joint space (P > 0.05). The lumbar facet joint space can be accurately demonstrated by ultrasound.

  8. Role of ultrasound guided transversus abdominis plane block as a component of multimodal analgesic regimen for lower segment caesarean section: a randomized double blind clinical study.

    PubMed

    Jadon, Ashok; Jain, Priyanka; Chakraborty, Swastika; Motaka, Mayur; Parida, Sudhansu Sekhar; Sinha, Neelam; Agrawal, Amit; Pati, Asit Kumar

    2018-05-14

    While opioids are the mainstay for post-operative analgesia after lower segment caesarean section, they are associated with various untoward effects. Ultrasound guided transversus abdominis plane (TAP) block has been postulated to provide effective analgesia for caesarean section. We evaluated the analgesic efficacy of this block for post caesarean analgesia in a randomised controlled trial. One hundred thirty-nine mothers undergoing caesarean delivery were randomised to receive TAP block with either 20 ml 0.375% ropivacaine or 20 ml saline after obtaining informed consent. All the subjects received a standard spinal anaesthetic and diclofenac was administered for post-operative pain. Breakthrough pain was treated with tramadol. Post-operatively, all the subjects were assessed at 0, 2, 4, 6, 8, 10, 12, 18 & 24 h. The primary outcome was the time to first analgesic request. The secondary measures of outcome were pain, nausea, sedation, number of doses of tramadol administered and satisfaction with the pain management. The median (interquartile range) time to first analgesic request was prolonged in the TAP group compared to the control group (p < 0.0001); 11 h (8,12) and 4 h (2.5,6) respectively. The median (interquartile range) number of doses of tramadol consumed in the TAP group was 0 (0,1) compared to 2 (1,2) in the control group (p < 0.0001). At all points in the study, pain scores both at rest and on movement were lower in the study group (p < 0.0001). Maternal satisfaction with pain relief was also higher in the study group (p 0.0002). One subject in the TAP group had convulsions following injection of local anaesthetic solution. She was managed conservatively with supportive treatment following which she recovered. TAP block reduces pain, prolongs the duration of analgesia and decreases supplemental opioid consumption when used for multimodal analgesia for pain relief after caesarean section. However, the risk of local anaesthetic systemic toxicity remains unknown with this block. Hence larger safety trials and measures to limit this complication need to be ascertained. The trial was registered with the Clinical Trial Registry of India ( CTRI/2017/03/008194 ) on 23/03/2017 (trial registered retrospectively).

  9. The analgesic efficacy of ultrasound-guided transversus abdominis plane block on postoperative pain and morphine consumption in varicocelectomy.

    PubMed

    Ömür, Dilek; Oğuzalp, Hüseyin; Kiraz, Hasan A; Ekin, Serpil; Alan, Cabir; Ersay, Ahmet R; Hancı, Volkan

    2016-06-01

    To evaluate the analgesic effect of transversus abdominis plane (TAP) block administered before varicocele surgery. This study was completed at the Faculty of Medicine, Çanakkale Onsekiz Mart University, Çanakkale, Turkey, between January 2011 and April 2013. In a prospective, double blind, randomized, placebo controlled clinical study, 40 male patients scheduled for elective varicocele operations were randomized to group T (treatment group) or group C (controls). After receiving general anesthesia, group T received a TAP block using 20 mL 0.25% bupivacaine on the operation side, whereas group C received a control block using 20 mL 0.9% Sodium chloride. During the first 24 hours after surgery, the patient pain was evaluated using the visual analogue scale (VAS) at rest and while coughing. Postoperative patient controlled analgesia morphine consumption, VAS scores, and side effects were recorded. Of 34 patients, Group T (n=18) had significantly lower VAS pain scores than Group C (n=16) both at rest and while coughing. The total morphine consumed was  lower (7.7 ± 4.0) versus 21.6 ± 12.4 mg, p less than 0.001) in the 24 hours after surgery. As part of a multimodal analgesic regime after varicocelectomy surgery, morphine consumption and VAS pain scores were significantly lower among those receiving 20 mL 0.25% bupivacaine administered for a TAP block than among controls.

  10. Comparison of portable and conventional ultrasound imaging in spinal curvature measurement

    NASA Astrophysics Data System (ADS)

    Yan, Christina; Tabanfar, Reza; Kempston, Michael; Borschneck, Daniel; Ungi, Tamas; Fichtinger, Gabor

    2016-03-01

    PURPOSE: In scoliosis monitoring, tracked ultrasound has been explored as a safer imaging alternative to traditional radiography. The use of ultrasound in spinal curvature measurement requires identification of vertebral landmarks, but bones have reduced visibility in ultrasound imaging and high quality ultrasound machines are often expensive and not portable. In this work, we investigate the image quality and measurement accuracy of a low cost and portable ultrasound machine in comparison to a standard ultrasound machine in scoliosis monitoring. METHODS: Two different kinds of ultrasound machines were tested on three human subjects, using the same position tracker and software. Spinal curves were measured in the same reference coordinate system using both ultrasound machines. Lines were defined by connecting two symmetric landmarks identified on the left and right transverse process of the same vertebrae, and spinal curvature was defined as the transverse process angle between two such lines, projected on the coronal plane. RESULTS: Three healthy volunteers were scanned by both ultrasound configurations. Three experienced observers localized transverse processes as skeletal landmarks and obtained transverse process angles in images obtained from both ultrasounds. The mean difference per transverse process angle measured was 3.00 +/-2.1°. 94% of transverse processes visualized in the Sonix Touch were also visible in the Telemed. Inter-observer error in the Telemed was 4.5° and 4.3° in the Sonix Touch. CONCLUSION: Price, convenience and accessibility suggest the Telemed to be a viable alternative in scoliosis monitoring, however further improvements in measurement protocol and image noise reduction must be completed before implementing the Telemed in the clinical setting.

  11. Theranostic Gd(III)-lipid microbubbles for MRI-guided focused ultrasound surgery.

    PubMed

    Feshitan, Jameel A; Vlachos, Fotis; Sirsi, Shashank R; Konofagou, Elisa E; Borden, Mark A

    2012-01-01

    We have synthesized a biomaterial consisting of Gd(III) ions chelated to lipid-coated, size-selected microbubbles for utility in both magnetic resonance and ultrasound imaging. The macrocyclic ligand DOTA-NHS was bound to PE headgroups on the lipid shell of pre-synthesized microbubbles. Gd(III) was then chelated to DOTA on the microbubble shell. The reaction temperature was optimized to increase the rate of Gd(III) chelation while maintaining microbubble stability. ICP-OES analysis of the microbubbles determined a surface density of 7.5 × 10(5) ± 3.0 × 10(5) Gd(III)/μm(2) after chelation at 50 °C. The Gd(III)-bound microbubbles were found to be echogenic in vivo during high-frequency ultrasound imaging of the mouse kidney. The Gd(III)-bound microbubbles also were characterized by magnetic resonance imaging (MRI) at 9.4 T by a spin-echo technique and, surprisingly, both the longitudinal and transverse proton relaxation rates were found to be roughly equal to that of no-Gd(III) control microbubbles and saline. However, the relaxation rates increased significantly, and in a dose-dependent manner, after sonication was used to fragment the Gd(III)-bound microbubbles into non-gas-containing lipid bilayer remnants. The longitudinal (r(1)) and transverse (r(2)) molar relaxivities were 4.0 ± 0.4 and 120 ± 18 mM(-1)s(-1), respectively, based on Gd(III) content. The Gd(III)-bound microbubbles may find application in the measurement of cavitation events during MRI-guided focused ultrasound therapy and to track the biodistribution of shell remnants. Copyright © 2011 Elsevier Ltd. All rights reserved.

  12. Influence of inward pressure of the transducer on lateral abdominal muscle thickness during ultrasound imaging.

    PubMed

    Ishida, Hiroshi; Watanabe, Sususmu

    2012-09-01

    Controlled laboratory study, technical note. The purpose of this study was to quantify changes in the thickness of the transversus abdominis, internal oblique, and external oblique muscles induced by different inward pressures of the transducer during ultrasound imaging (USI). USI of the lateral abdominal muscles is increasingly used in managing musculoskeletal dysfunction. However, to the best of our knowledge, no study has evaluated the influence of different inward pressures of the transducer on the lateral abdominal muscle thickness during USI. Thirty healthy male volunteers participated in this study. The thickness of the transversus abdominis, internal oblique, and external oblique muscles was measured with USI by the same rater in 4 conditions of inward pressures of 0.5, 1.0, 2.0, and 4.0 N. Intraclass correlation coefficients (ICC1,1), with 95% confidence intervals, were calculated, and a repeated-measures analysis of variance was used to assess the influence of inward pressure on the thickness of the lateral abdominal muscles. The thickness of the transversus abdominis, internal oblique, and external oblique muscles was significantly different among the 4 conditions (P<.038). The mean difference between the 0.5-N and 4.0-N conditions was greater than the minimal detectable change of the 0.5-N condition in the lateral abdominal muscles. The difference in magnitude produced by the forces under different conditions was meaningful. When using a technique that involves a handheld transducer, the examiner should attempt to maintain consistent inward pressure of the transducer during USI to quantify the thickness of lateral abdominal muscles. J Orthop Sports Phys Ther 2012;42(9):815-818, Epub 19 April 2012. doi:10.2519/jospt.2012.4064.

  13. [Clinical auxiliary diagnosis value of high frequency ultrasonographic measurements of the thickness of transverse carpal ligaments in carpal tunnel syndrome patients].

    PubMed

    Xu, L; Chen, F M; Wang, L; Zhang, P X; Jiang, X R

    2016-04-18

    To evaluate the meaning and value of high-frequency ultrasound in the diagnosis of carpal tunnel syndrome (CTS). In this study, 48 patients (unilateral hand) with CTS were analyzed. The thickness of transverse carpal ligaments at the pisiform bone was measured using high-frequency ultrasound. Open carpal tunnel release procedure was performed in the 48 CTS patients, and the thickness of transverse carpal ligaments at the hamate hook bone measured using vernier caliper under direct vision. The accuracy of thickness of transverse carpal ligaments was evaluated using high-frequency ultrasound. high-frequency ultrasound measurement of thickness of transverse carpal ligaments at the hamate hook bone and pisiform bone, and determination of the diagnostic threshold measurement index using receiver operating characteristic (ROC) curve, sensitivity and specificity were performed and the correlation between the thickness of transverse carpal ligaments and nerve conduction study (NCS) analyzed. The thickness of transverse carpal ligaments in the CTS patients were (0.42±0.08) cm (high-frequency ultrasound) and (0.41±0.06) cm (operation) at hamate hook bone, and there was no significant difference between the two ways (t=0.672, P>0.05). The optimal cut-off value of the transverse carpal ligaments at hamate hook bone was 0.385 cm, the sensitivity 0.775, and the specificity 0.788. The optimal cut-off value of the transverse carpal ligaments at the pisiform bone was 0.315 cm, the sensitivity 0.950, and the specificity 1.000. The transverse carpal ligaments thickness and wrist-index finger sensory nerve conduction velocity (SCV), wrist-middle finger SCV showed a negative correlation. High frequency ultrasound measurements of thickness of transverse carpal ligaments is a valuable method for the diagnosis of CTS.

  14. Mechanical and histological characterization of the abdominal muscle. A previous step to modelling hernia surgery.

    PubMed

    Hernández, B; Peña, E; Pascual, G; Rodríguez, M; Calvo, B; Doblaré, M; Bellón, J M

    2011-04-01

    The aims of this study are to experimentally characterize the passive elastic behaviour of the rabbit abdominal wall and to develop a mechanical constitutive law which accurately reproduces the obtained experimental results. For this purpose, tissue samples from New Zealand White rabbits 2150±50 (g) were mechanically tested in vitro. Mechanical tests, consisting of uniaxial loading on tissue samples oriented along the craneo-caudal and the perpendicular directions, respectively, revealed the anisotropic non-linear mechanical behaviour of the abdominal tissues. Experiments were performed considering the composite muscle (including external oblique-EO, internal oblique-IO and transverse abdominis-TA muscle layers), as well as separated muscle layers (i.e., external oblique, and the bilayer formed by internal oblique and transverse abdominis). Both the EO muscle layer and the IO-TA bilayer demonstrated a stiffer behaviour along the transversal direction to muscle fibres than along the longitudinal one. The fibre arrangement was measured by means of a histological study which confirmed that collagen fibres are mainly responsible for the passive mechanical strength and stiffness. Furthermore, the degree of anisotropy of the abdominal composite muscle turned out to be less pronounced than those obtained while studying the EO and IO-TA separately. Moreover, a phenomenological constitutive law was used to capture the measured experimental curves. A Levenberg-Marquardt optimization algorithm was used to fit the model constants to reproduce the experimental curves. Copyright © 2010 Elsevier Ltd. All rights reserved.

  15. Rectus abdominis muscle injuries in elite handball players: management and rehabilitation

    PubMed Central

    Balius, Ramon; Pedret, Carles; Pacheco, Laura; Gutierrez, Josep Antoni; Vives, Joan; Escoda, Jaume

    2011-01-01

    Muscle injuries generally occur in two-joint muscles with a high percentage of type II fibers during the performance of eccentric activity. Some muscle injuries, such as those located in the adductor longus, a monoarticular muscle, as well as rectus abdominis do not fully comply with these requirements. This study examines five cases of elite handball players with ruptured rectus abdominals. Sonographically, lesions in rectus abdominis are shown as a disruption of the fibrillar pattern with a hematic suffusion that invades the entire lesion. In some of the cases, the ultrasound study was complemented with a MRI. A unified rehabilitation protocol was applied and the return to play time of each handball player ranged between 16 and 22 days, with an average of 18.2 days. Follow-up at 15 months showed no evidence of re-injury or residual discomfort and all of them are playing at their highest level. The aim of this study was to illustrate a feature of handball injury that, as in tennis and volleyball, is uncommon and so far has not been specifically reported. The phenomenon of contralateral abdominal hypertrophy in handball appears in the dominant arm as in tennis and volleyball. PMID:24198573

  16. Ultrasound-guided transversus abdominal plane block with multimodal analgesia for pain management after total abdominal hysterectomy.

    PubMed

    Gasanova, Irina; Grant, Erica; Way, Megan; Rosero, Eric B; Joshi, Girish P

    2013-07-01

    Transversus abdominis plane (TAP) block has been shown to provide pain relief after abdominal procedures. However, TAP block combined with multimodal analgesia technique have not been assessed in a randomized controlled trial. This randomized, controlled, observer-blinded study was designed to evaluate the analgesic efficacy of bilateral ultrasound-guided TAP blocks with or without acetaminophen and non-steroidal anti-inflammatory drug (NSAID) combination. Patients undergoing total abdominal hysterectomy were randomized to one of three groups. Group 1 (n = 25) received a TAP block and ketorolac 30 mg, IV at the end of surgery and then ketorolac plus paracetamol 650 mg, orally, every 6 h for 24 h. Group 2 (n = 24) received only TAP block at the end of surgery. Group 3 (n = 25) received ketorolac 30 mg, IV at the end of surgery and then ketorolac plus paracetamol 650 mg, orally, every 6 h for 24 h. All patients received IV-PCA morphine for 24-h, postoperatively. All patients received a standardized general anaesthetic technique and dexamethasone 4 mg and ondansetron 4 mg, IV for antiemetic prophylaxis. There were no statistically significant differences in pain at rest between the groups. However, the pain on coughing (dynamic pain) in Group 1 was significantly less variable, compared with the other two groups (P = 0.012). Opioid consumption and occurrences of nausea, vomiting, and rescue antiemetic were similar in three the groups. The combination of TAP block and acetaminophen and NSAID provided less variability in dynamic pain compared with either treatment alone.

  17. Scaled signal intensity of uterine fibroids based on T2-weighted MR images: a potential objective method to determine the suitability for magnetic resonance-guided focused ultrasound surgery of uterine fibroids.

    PubMed

    Park, Hyun; Yoon, Sang-Wook; Sokolov, Amit

    2015-12-01

    Magnetic Resonance-guided Focused Ultrasound Surgery (MRgFUS) is a non-invasive method to treat uterine fibroids. To help determine the patient suitability for MRgFUS, we propose a new objective measure: the scaled signal intensity (SSI) of uterine fibroids in T2 weighted MR images (T2WI). Forty three uterine fibroids in 40 premenopausal women were included in this retrospective study. SSI of each fibroid was measured from the screening T2WI by standardizing its mean signal intensity to a 0-100 scale, using reference intensities of rectus abdominis muscle (0) and subcutaneous fat (100). Correlation between the SSI and the non-perfused volume (NPV) ratio (a measure for treatment success) was calculated. Pre-treatment SSI showed a significant inverse-correlation with post treatment NPV ratio (p < 0.05). When dichotomizing NPV ratio at 45 %, the optimal cut off value of the SSI was found to be 16.0. A fibroid with SSI value 16.0 or less can be expected to have optimal responses. The SSI of uterine fibroids in T2WI can be suggested as an objective parameter to help in patient selection for MRgFUS. • Signal intensity of fibroid in MR images predicts treatment response to MRgFUS. • Signal intensity is standardized into scaled form using adjacent tissues as references. • Fibroids with SSI less than 16.0 are expected to have optimal responses.

  18. Transverse acoustic trapping using a Gaussian focused ultrasound

    PubMed Central

    Lee, Jungwoo; Teh, Shia-Yen; Lee, Abraham; Kim, Hyung Ham; Lee, Changyang; Shung, K. Kirk

    2009-01-01

    The optical tweezer has become a popular device to manipulate particles in nanometer scales, and to study the underlying principles of many cellular or molecular interactions. Theoretical analysis was previously carried out at the authors’ laboratory, to show that similar acoustic trapping of microparticles may be possible with a single beam ultrasound. This paper experimentally presents the transverse trapping of 125 μm lipid droplets under an acoustically transparent mylar film, which is an intermediate step toward achieving acoustic tweezers in 3D. Despite the lack of axial trapping capability in the current experimental arrangement, it was found that a 30 MHz focused beam could be used to laterally direct the droplets towards the focus. The spatial range within which acoustic traps may guide droplet motion was in the range of hundreds of micrometers, much greater than that of optical traps. This suggests that this acoustic device may offer an alternative for manipulating microparticles in a wider spatial range. PMID:20045590

  19. Percutaneous Ultrasound-Guided Carpal Tunnel Release: Study Upon Clinical Efficacy and Safety

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Petrover, David, E-mail: dpetrover@yahoo.fr; Silvera, Jonathan, E-mail: silvera.jonathan@gmail.com; Baere, Thierry De, E-mail: Debaere@igr.fr

    ObjectivesTo evaluate the feasibility and 6 months clinical result of sectioning of the transverse carpal ligament (TCL) and median nerve decompression after ultra-minimally invasive, ultrasound-guided percutaneous carpal tunnel release (PCTR) surgery.MethodsConsecutive patients with carpal tunnel syndrome were enrolled in this descriptive, open-label study. The procedure was performed in the interventional radiology room. Magnetic resonance imaging was performed at baseline and 1 month. The Boston Carpal Tunnel Questionnaire was administered at baseline, 1, and 6 months.Results129 patients were enrolled. Significant decreases in mean symptom severity scores (3.3 ± 0.7 at baseline, 1.7 ± 0.4 at Month 1, 1.3 ± 0.3 at Month 6) and mean functional status scores (2.6 ± 1.1 atmore » baseline, 1.6 ± 0.4 at Month 1, 1.3 ± 0.5 at Month 6) were noted. Magnetic resonance imaging showed a complete section of all TCL and nerve decompression in 100% of patients. No complications were identified.ConclusionsUltrasound-guided PCTR was used successfully to section the TCL, decompress the median nerve, and reduce self-reported symptoms.« less

  20. Ultrasound evaluation of muscle thickness changes in the external oblique, internal oblique, and transversus abdominis muscles considering the influence of posture and muscle contraction.

    PubMed

    Sugaya, Tomoaki; Abe, Yota; Sakamoto, Masaaki

    2014-09-01

    [Purpose] The aim of this study was to investigate muscle thickness changes in the external oblique (EO), internal oblique (IO), and transversus abdominis (TrA) muscles between the neutral position and trunk rotation, under a state of rest without voluntary contractions, and isometric contractions to both sides with resistance of 50% of the maximum trunk rotation strength. [Subjects] The subjects of this study were 21 healthy young men. [Methods] Muscle thickness changes in the EO, IO, and TrA in each position and state were evaluated by ultrasound. The range of motion at maximum trunk rotation and the maximum strength of trunk rotation were measured using a hand-held dynamometer. [Results] In the neutral position and at 50% trunk rotation to the right side, the thicknesses of the IO and TrA significantly increased with resistance. In both states, the thicknesses of the IO and TrA significantly increased at 50% trunk rotation to the right side. [Conclusion] The muscular contractions of the IO and TrA were stronger during ipsilateral rotation than in the neutral position and with resistance than at rest. Moreover, the muscular contraction was strongest in the resistive state during ipsilateral rotation.

  1. Ultrasound Assessment of Abdominal Muscle Thickness in Women With and Without Low Back Pain During Pregnancy.

    PubMed

    Weis, Carol Ann; Nash, Jennifer; Triano, John J; Barrett, Jon

    2017-05-01

    The aim of this preliminary study was to determine the differences in abdominal musculature thickness, within 1 month of delivery, in women who experienced back pain during pregnancy compared with those who did not. B-mode ultrasound imaging was used to measure abdominal muscle thickness on 76 postpartum participants who participated in a larger study; 47 women experienced back pain during pregnancy, and 29 did not. Participant data were stratified by group, and primary comparisons were based on these grouping across the abdominal muscles, including rectus abdominis (upper and lower fibers), external oblique, internal oblique, and transversus abdominis. Means and standard deviations were also used to set parameters for future studies. In the present study, there was no difference in any abdominal muscle thickness between groups. Women with low back pain were significantly shorter (165.19 ± 6.64 cm) than women who did not have from back pain during pregnancy (169.38 ± 7.58 cm). All other demographics, such as age, weight, and date tested postpartum, were not significantly different between groups. The results of this study showed no variation in abdominal muscle thickness in women who had back pain during pregnancy and those who did not. Copyright © 2017. Published by Elsevier Inc.

  2. Preoperative TRAM free flap volume estimation for breast reconstruction in lean patients.

    PubMed

    Minn, Kyung Won; Hong, Ki Yong; Lee, Sang Woo

    2010-04-01

    To obtain pleasing symmetry in breast reconstruction with transverse rectus abdominis myocutaneous (TRAM) free flap, a large amount of abdominal flap is elevated and remnant tissue is trimmed in most cases. However, elevation of abundant abdominal flap can cause excessive tension in donor site closure and increase the possibility of hypertrophic scarring especially in lean patients. The TRAM flap was divided into 4 zones in routine manner; the depth and dimension of the 4 zones were obtained using ultrasound and AutoCAD (Autodesk Inc., San Rafael, CA), respectively. The acquired numbers were then multiplied to obtain an estimate of volume of each zone and the each zone volume was added. To confirm the relation between the estimated volume and the actual volume, authors compared intraoperative actual TRAM flap volumes with preoperative estimated volumes in 30 consecutive TRAM free flap breast reconstructions. The estimated volumes and the actual elevated volumes of flap were found to be correlated by regression analysis (r = 0.9258, P < 0.01). According to this result, we could confirm the reliability of the preoperative volume estimation using our method. Afterward, the authors applied this method to 7 lean patients by estimation and revision of the design and obtained symmetric results with minimal donor site morbidity. Preoperative estimation of TRAM flap volume with ultrasound and AutoCAD (Autodesk Inc.) allow the authors to attain the precise volume desired for elevation. This method provides advantages in terms of minimal flap trimming, easier closure of donor sites, reduced scar widening and symmetry, especially in lean patients.

  3. Exercise and Transversus Abdominis Muscle Atrophy after 60-d Bed Rest.

    PubMed

    Belavý, Daniel Ludovic; Gast, Ulf; Felsenberg, Dieter

    2017-02-01

    This study aimed to investigate atrophy in the deep abdominal muscles, spinal extensors, and the effect of high-load resistive exercise with and without whole-body vibration after 60 d of strict bed rest. Twenty-four subjects underwent 60 d of head-down tilt bed rest and performed either resistive vibration exercise (RVE), resistive exercise only (RE), or no exercise control (2nd Berlin BedRest Study). The thickness of the transversus abdominis, internal oblique, and erector spinae muscles and the area of the multifidus muscle were measured bilaterally via real-time ultrasound. Intention-to-treat analysis was implemented, and P values were adjusted by the false discovery rate method. At the end of the bed rest, transversus abdominis thickness was reduced by 18.3% in the inactive group (P = 0.00011) with no significant change in the RVE (-4.0%; P = 0.014 vs control) or RE (-5.0%; P = 0.10 vs control) groups. In the inactive subjects, internal oblique thickness reduced by 10.6% (P = 0.0025) and by 7% (P > 0.05) in each of the training groups. The lengthening of the lumbar spine was greatest on day 1 (+7.4%, P = 0.004) and day 2 (+6.3%, P = 0.004; day 54: +4.1%, P = 0.023). A 4.7% reduction of multifidus area was observed on day 1 of bed rest (P = 0.0049) and a 4.2% reduction of erector spinae thickness was observed on day 2 (P = 0.0011). Extensor atrophy and spinal lengthening was not affected by exercise. No significant difference was seen between RVE and RE. Bed rest leads to atrophy of the transversus abdominis and internal oblique muscles. The exercise program, which implemented lower-limb and back extension exercises against shoulder restraints, was able to reduce atrophy seen in transversus abdominis in bed rest.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shirkhoda, A; Mauro, M.A.; Staab, E.V.

    Fifty-four hemophiliac patients underwent a total of 94 studies using computed tomography (CT), ultrasound, or both. Not only common bleeding sites such as the iliopsoas muscles but also several unusual sites were encountered: these included th iliac bone, bowel wall, mesentery, rectus abdominis muscle, retroperitoneum, bladder wall, and scrotum. Both modalities gave comparable results, and each was helpful in (a) establishing the diagnosis, (b) evaluating the extent of bleeding and its effect on adjacent organs, and (c) demonstrating regression after treatment.

  5. Transversus Abdominis Plane Block Versus Surgical Site Infiltration for Pain Management After Open Total Abdominal Hysterectomy.

    PubMed

    Gasanova, Irina; Alexander, John; Ogunnaike, Babatunde; Hamid, Cherine; Rogers, David; Minhajuddin, Abu; Joshi, Girish P

    2015-11-01

    Surgical site infiltration and transversus abdominis plane (TAP) blocks are commonly used to improve pain relief after lower abdominal surgery. This randomized, observer-blinded study was designed to compare the analgesic efficacy of TAP blocks with surgical site infiltration in patients undergoing open total abdominal hysterectomy via a Pfannenstiel incision. Patients were randomized to receive either bilateral ultrasound-guided TAP blocks using bupivacaine 0.5% 20 mL on each side (n = 30) or surgical site infiltration with liposomal bupivacaine 266 mg diluted to 60 mL injected in the preperitoneal, subfascial, and subcutaneous planes (n = 30). The remaining aspects of the perioperative care were standardized. An investigator blinded to the group allocation documented pain scores at rest and with coughing, opioid requirements, nausea, vomiting, and rescue antiemetics in the postanesthesia care unit and at 2, 6, 12, 24, and 48 hours postoperatively. The primary outcome measure was pain scores on coughing at 6 hours postoperatively. One patient in each group was excluded from the analysis because of reoperation within 24 hours in the TAP block group and change of incision type in the infiltration group. The pain scores at rest and with coughing were significantly lower in the surgical site infiltration group at all postoperative time points (P < 0.0001) except at rest in the postanesthesia care unit. The opioid requirements between 24 and 48 hours were significantly lower in the infiltration group (P = 0.009). The nausea scores, occurrence of vomiting, and need for rescue antiemetics were similar. Surgical site infiltration provided superior pain relief at rest and on coughing, as well as reduced opioid consumption for up to 48 hours. Future studies need to compare TAP blocks with liposomal bupivacaine with surgical site infiltration with liposomal bupivacaine.

  6. Postoperative Analgesic Efficacy of Bilateral Transversus Abdominis Plane Block in Patients Undergoing Midline Colorectal Surgeries Using Ropivacaine: A Randomized, Double-blind, Placebo-controlled Trial.

    PubMed

    Qazi, Nahida; Bhat, Wasim Mohammad; Iqbal, Malik Zaffar; Wani, Anisur Rehman; Gurcoo, Showkat A; Rasool, Sahir

    2017-01-01

    Ultrasound-guided transversus abdominis plane (TAP) block is done as a part of multimodal analgesia for pain relief after abdominal surgeries. This prospective randomized, double-blind, placebo-controlled trial was conducted to evaluate the postoperative analgesic efficacy of bilateral TAP block in patients undergoing midline colorectal surgeries using ropivacaine. Eighty patients scheduled for elective colorectal surgeries involving midline abdominal wall incision under general anesthesia were enrolled in this prospective randomized controlled trial. Group A received TAP block with 20 ml of 0.2% ropivacaine on either side of the abdominal wall, and Group B received 20 ml of normal saline. The time to request for rescue analgesia, total analgesic consumption in 24 h, and satisfaction with the anesthetic technique were assessed. The mean visual analog scale scores at rest and on coughing were higher in control group ( P > 0.05). Time (min) to request for the first rescue analgesia was prolonged in study group compared to control group ( P < 0.001). The total tramadol consumption in 24 h postoperatively was significantly high in control group ( P < 0.001). Nausea/vomiting was more common in control group ( P > 0.05). The level of satisfaction concerning postoperative pain control/anesthetic technique was higher in study group ( P < 0.001). TAP block produces effective and prolonged postoperative analgesia in patients undergoing midline colorectal surgery. It is a technically simple block to perform with a high margin of safety. It produces a considerable reduction in mean intravenous postoperative tramadol requirements, reduction in postoperative pain scores, and increased time to first request for further analgesia, both at rest and on movement.

  7. Transversus abdominis plane block vs. wound infiltration in Caesarean section: a randomised controlled trial.

    PubMed

    Telnes, A; Skogvoll, E; Lonnée, H

    2015-04-01

    Multiple studies suggest that transversus abdominis plane (TAP) block (without intrathecal morphine) after Caesarean section (CS) reduces post-operative morphine consumption. In our study, we wanted to compare the analgesic effect of TAP block with infiltration of the wound after CS. We included 60 pregnant women scheduled for elective CS under spinal anaesthesia in a randomised, single-centre, double-blind study. Thirty patients received ultrasound-guided TAP block using 20 ml bupivacaine 0.25% with adrenaline 5 μg/ml bilaterally and 20 ml normal saline as wound infiltration (TAP group). The other 30 patients (the control group) received normal saline 20 ml bilaterally in the TAP, and 20 ml bupivacaine 0.25% with adrenaline 5 μg/ml as wound infiltration. The main outcome was cumulative morphine consumption at 48 h after surgery. In addition, continuous morphine consumption, pain scores and side effects were registered. Fifty-seven patients completed the study. Cumulative morphine consumption at 48 h (mean±standard deviation) was 41±34 mg in the TAP group and 38±27 mg in the control group (P=0.7); a difference of 3 mg (95% confidence interval -13 to 19 mg). Morphine consumption at any time up to 48 h was virtually identical in both groups. Side effects were similar, except for a higher degree of sedation in the TAP group (P=0.04). Compared with wound infiltration with local anaesthetics, TAP block did not reduce cumulative morphine consumption following CS. The TAP block was associated with more pronounced sedation. © 2015 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  8. Postoperative Analgesic Efficacy of Bilateral Transversus Abdominis Plane Block in Patients Undergoing Midline Colorectal Surgeries Using Ropivacaine: A Randomized, Double-blind, Placebo-controlled Trial

    PubMed Central

    Qazi, Nahida; Bhat, Wasim Mohammad; Iqbal, Malik Zaffar; Wani, Anisur Rehman; Gurcoo, Showkat A.; Rasool, Sahir

    2017-01-01

    Background: Ultrasound-guided transversus abdominis plane (TAP) block is done as a part of multimodal analgesia for pain relief after abdominal surgeries. This prospective randomized, double-blind, placebo-controlled trial was conducted to evaluate the postoperative analgesic efficacy of bilateral TAP block in patients undergoing midline colorectal surgeries using ropivacaine. Materials and Methods: Eighty patients scheduled for elective colorectal surgeries involving midline abdominal wall incision under general anesthesia were enrolled in this prospective randomized controlled trial. Group A received TAP block with 20 ml of 0.2% ropivacaine on either side of the abdominal wall, and Group B received 20 ml of normal saline. The time to request for rescue analgesia, total analgesic consumption in 24 h, and satisfaction with the anesthetic technique were assessed. Results: The mean visual analog scale scores at rest and on coughing were higher in control group (P > 0.05). Time (min) to request for the first rescue analgesia was prolonged in study group compared to control group (P < 0.001). The total tramadol consumption in 24 h postoperatively was significantly high in control group (P < 0.001). Nausea/vomiting was more common in control group (P > 0.05). The level of satisfaction concerning postoperative pain control/anesthetic technique was higher in study group (P < 0.001). Conclusion: TAP block produces effective and prolonged postoperative analgesia in patients undergoing midline colorectal surgery. It is a technically simple block to perform with a high margin of safety. It produces a considerable reduction in mean intravenous postoperative tramadol requirements, reduction in postoperative pain scores, and increased time to first request for further analgesia, both at rest and on movement. PMID:28928585

  9. Comparative effects of 12 weeks of equipment based and mat Pilates in patients with Chronic Low Back Pain on pain, function and transversus abdominis activation. A randomized controlled trial.

    PubMed

    Cruz-Díaz, David; Bergamin, M; Gobbo, S; Martínez-Amat, Antonio; Hita-Contreras, Fidel

    2017-08-01

    Pilates method has been recommended for patients with chronic low back pain (CLBP) and the activation of transversus abdominis has been deemed to play an important role in the improvement of these patients. Nevertheless, the evidence of the activation of TrA in Pilates practitioners remains unclear. To assess the effectiveness of 12 weeks of Pilates practice in disability, pain, kinesiophobia and transversus abdominis activation in patients with chronic nonspecific Low Back Pain. A randomized controlled trial was carried out. A single-blind randomized controlled trial with repeated measures at 6 and 12 weeks was carried out. A total of ninety eight patients with low back pain were included and randomly allocated to a Pilates Mat group (PMG) equipment based with apparatus Pilates (PAG) or control group (CG). Roland Morris Disability Questionnaire (RMDQ), visual analog scale (VAS) Tampa Scale of Kinesiophobia (TSK), and transversus abdominis (TrA) activation assessed by real time ultrasound measurement (US) were assessed as outcome measures. Improvement were observed in both intervention groups in all the included variables at 6 and 12 weeks (p<0.001). Faster enhancement was observed in the equipment based Pilates group (p=0.007). Equipment based and mat Pilates modalities are both effective in the improvement of TaA activation in patients with CLBP with associate improvement on pain, function and kinesiophobia. Significant differences were observed after 12 weeks of intervention in PMG and PAG with faster improvement in PAG suggesting that, feedback provided by equipment could help in the interiorization of Pilates principles. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. The influence of simulated transversus abdominis muscle force on sacroiliac joint flexibility during asymmetric moment application to the pelvis.

    PubMed

    Gnat, Rafael; Spoor, Kees; Pool-Goudzwaard, Annelies

    2015-10-01

    The role of so-called local muscle system in motor control of the lower back and pelvis is a subject of ongoing debate. Prevailing beliefs in stabilizing function of this system were recently challenged. This study investigated the impact of in vitro simulated force of transversely oriented fibres of the transversus abdominis muscle (a part of the local system) on flexibility of the sacroiliac joint during asymmetric moment application to the pelvis. In 8 embalmed specimens an incremental moment was applied in the sagittal plane to one innominate with respect to the fixed contralateral innominate. Ranges of motion of the sacroiliac joint were recorded using the Vicon Motion Capture System. Load-deformation curves were plotted and flexibility of the sacroiliac joint was calculated separately for anterior and posterior rotations of the innominate, with and without simulated muscle force. Flexibility of the sacroiliac joint was significantly bigger during anterior rotation of the innominate, as compared to posterior rotation (Anova P<0.05). After application of simulated force of transversus abdominis, flexibility of the joint did not change both during anterior and posterior rotations of the innominate. A lack of a stiffening effect of simulated transversus abdominis force on the sacroiliac joint was demonstrated. Earlier hypotheses suggesting a stiffening influence of this muscle on the pelvis cannot be confirmed. Consistent with previous findings smaller flexibility of the joint recorded during posterior rotation of the innominate may be of clinical importance for physio- and manual therapists. However, major limitations of the study should be acknowledged: in vitro conditions and simulation of only solitary muscle force. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. Comparison of the thickness of lateral abdominal muscles between pregnant women with and without low back pain.

    PubMed

    Rostami, Mohsen; Noormohammadpour, Pardis; Mansournia, Mohammad Ali; Hantoushzadeh, Sedigheh; Farahbakhsh, Farzin; Nourian, Ruhollah; Kordi, Ramin

    2015-05-01

    To compare the thickness of the external oblique, internal oblique, and transversus abdominis muscles in pregnant subjects with and without low back pain (LBP) by the use of ultrasound to measure thickness. A case-control study. An academic and tertiary care referral spine and sports medicine center. Fifty pregnant women with LBP during pregnancy and 54 pregnant control subjects. Case and control subjects were matched for body mass index, gestational age, and number of previous pregnancies. A multiple linear regression model with adjustment for the gestational age of the subjects, as the potential confounder of the primary outcomes, was used to evaluate the association between LBP appearance and abdominal muscles thickness of the subjects. The thickness of lateral abdominal muscles was measured by ultrasound with the subject in a hook-lying position on the examination table. We found that there was no significant difference between pregnant subjects with and without LBP in terms of the thickness of external oblique, internal oblique, and transversus abdominis muscles. These findings suggest that other factors rather than the thickness of core stabilizing muscles are influential in the etiology of LBP during pregnancy. We hypothesize that enlargement of uterus during pregnancy might influence the thickness of the lateral abdominal muscles. Copyright © 2015 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  12. The impact of the neurodevelopmental traction technique on activation of lateral abdominal muscles in children aged 11-13 years.

    PubMed

    Gogola, Anna; Gnat, Rafał; Dziub, Dorota; Gwóźdź, Michalina; Zaborowska, Małgorzata

    2016-06-27

    The aim of the study was to evaluate the activation of lateral abdominal muscles (LAM) in response to neurodevelopmental traction technique as assessed by ultrasounds as well as to compare the effects of different traction forces. An experiment with repeated measurements of the dependent variables was conducted. Thirty-seven children (22 girls) participated. Measurements of LAM thickness (indicating LAM activation) were performed bilaterally during traction of 5% body weight: 1) in neutral position, 2) in 20° posterior trunk inclination; during traction of 15% body weight: 3) in neutral position, 4) in 20° posterior trunk inclination. The ultrasound technology was employed. When applying the lighter traction the superficial LAM (external and internal oblique muscles) showed significant changes. The mean thickness of both muscles during traction increased (both p < 0.001). The deepest transversus abdominis showed no response (p > 0.05). Stronger traction elicited smaller changes. External and internal oblique muscles showed significant increases (p < 0.001, p < 0.01, respectively). Transversus abdominis became less thick during stronger traction (p < 0.01). The neurodevelopmental traction technique elicits the changes in LAM thickness in children with typical development. The superficial LAM show more distinct responses than the profound LAM. Stronger traction induces smaller LAM thickness changes than lighter traction.

  13. The number of operations required for completing breast reconstruction.

    PubMed

    Eom, Jin Sup; Kobayashi, Mark Robert; Paydar, Keyianoosh; Wirth, Garrett A; Evans, Gregory R D

    2014-10-01

    Breast reconstruction often requires multiple surgeries, which demands additional expense and time and is often contrary to the patient's expectation. The aim of this study was to review the number of operations that were needed for completion of breast reconstruction and to determine patient and clinical factors that influenced this number. We retrospectively reviewed the medical records of 254 cases of breast reconstructions (in 185 patients) that were performed between February 2005 and August 2009. We investigated the numbers of operations that were performed for individual case of breast reconstruction and analyzed the influence of variable factors. The purpose of the additional operations was also analyzed. The mean number of operations per breast was 2.37 (range, 1-9). The mean number of operations for mound creation was 2.24. Factors associated with an increased number of operation were use of an implant, contralateral symmetrization, complications, and nipple reconstruction. Considering the reconstruction method, either the use of a primary implant or the use of free abdominal tissue transfer demonstrated fewer surgeries than the use of an expander implant, and the number of operations using free transverse rectus abdominis musculocutaneous or deep inferior epigastric perforator flaps was less than the number of operations using pedicled transverse rectus abdominis musculocutaneous flaps. These data will aid in planning breast reconstruction surgery and will enable patients to be more informed regarding the likelihood of multiple surgeries.

  14. Reliability of real-time ultrasound measurement of transversus abdominis thickness in healthy trained subjects.

    PubMed

    Gnat, Rafael; Saulicz, Edward; Miądowicz, Barbara

    2012-08-01

    To investigate intra- and inter-rater reliability of the ultrasound measurement of transversus abdominis (TrA) thickness and thickness change (difference between thickness at rest and during contraction) in asymptomatic, trained subjects. To define the number of repeated measurements that provide acceptable level of reliability. To investigate variability of the measurements over time of 5 days and the reliability of duplicate analysis of images. A single-group repeated-measures design was used to assess reliability. Healthy volunteers (n = 10) were subjected to 1-week training in voluntary activation of TrA. Real-time ultrasound imaging and subsequent measurement of the TrA thickness at rest and during voluntary contraction were repeated on Monday, Wednesday and Friday of the next week. Using a single repeated measurement, intraclass correlation coefficients (ICCs) for TrA thickness were: 0.86-0.95 (intra-rater), 0.86-0.92 (inter-rater); and for TrA thickness change: 0.34-0.56 (intra-rater), 0.47-0.61 (inter-rater). Using the mean of three repeated measurements respective values were: 0.97, 0.96-0.98; and 0.81-0.84, 0.80-0.90. No significant differences were found between mean values of TrA thickness as well as thickness change obtained on three consecutive measurement days. Duplicate analysis of the images was highly reliable with ICCs of 0.89-0.99. Two repeated measurements for TrA thickness and at least three measurements for TrA thickness change are needed to achieve acceptable levels of intra- and inter-rater reliability. In healthy trained volunteers TrA thickness and thickness change are relatively stable parameters over a 5-day period. Duplicate analysis of the same images by two blinded observers is reliable.

  15. A novel transperitoneal abdominal wall nerve block for postoperative pain in laparoscopic colorectal surgery.

    PubMed

    Nagata, Jun; Watanabe, Jun; Sawatsubashi, Yusuke; Akiyama, Masaki; Arase, Koichi; Minagawa, Noritaka; Torigoe, Takayuki; Hamada, Kotaro; Nakayama, Yoshifumi; Hirata, Keiji

    2017-04-04

    Although the laparoscopic approach reduces pain associated with abdominal surgery, postoperative pain remains a problem. Ultrasound-guided rectus sheath block and transversus abdominis plane block have become increasingly popular means of providing analgesia for laparoscopic surgery. Ninety patients were enrolled in this study. A laparoscopic puncture needle was inserted via the port, and levobupivacaine was injected into the correct plane through the peritoneum. The patients' postoperative pain intensity was assessed using a numeric rating scale. The effects of laparoscopic nerve block versus percutaneous anesthesia were compared. This novel form of transperitoneal anesthesia did not jeopardize completion of the operative procedures. The percutaneous approach required more time for performance of the procedure than the transperitoneal technique. This new analgesia technique can become an optional postoperative treatment regimen for various laparoscopic abdominal surgeries. What we mainly want to suggest is that the transperitoneal approach has the advantage of a higher completion rate. A percutaneous technique is sometimes difficult with patients who have severe obesity and/or coagulation disorders. Additional studies are required to evaluate its benefits. Copyright © 2017. Published by Elsevier Taiwan.

  16. Localization of the transverse processes in ultrasound for spinal curvature measurement

    NASA Astrophysics Data System (ADS)

    Kamali, Shahrokh; Ungi, Tamas; Lasso, Andras; Yan, Christina; Lougheed, Matthew; Fichtinger, Gabor

    2017-03-01

    PURPOSE: In scoliosis monitoring, tracked ultrasound has been explored as a safer imaging alternative to traditional radiography. The use of ultrasound in spinal curvature measurement requires identification of vertebral landmarks such as transverse processes, but as bones have reduced visibility in ultrasound imaging, skeletal landmarks are typically segmented manually, which is an exceedingly laborious and long process. We propose an automatic algorithm to segment and localize the surface of bony areas in the transverse process for scoliosis in ultrasound. METHODS: The algorithm uses cascade of filters to remove low intensity pixels, smooth the image and detect bony edges. By applying first differentiation, candidate bony areas are classified. The average intensity under each area has a correlation with the possibility of a shadow, and areas with strong shadow are kept for bone segmentation. The segmented images are used to reconstruct a 3-D volume to represent the whole spinal structure around the transverse processes. RESULTS: A comparison between the manual ground truth segmentation and the automatic algorithm in 50 images showed 0.17 mm average difference. The time to process all 1,938 images was about 37 Sec. (0.0191 Sec. / Image), including reading the original sequence file. CONCLUSION: Initial experiments showed the algorithm to be sufficiently accurate and fast for segmentation transverse processes in ultrasound for spinal curvature measurement. An extensive evaluation of the method is currently underway on images from a larger patient cohort and using multiple observers in producing ground truth segmentation.

  17. Comparison of efficacy and safety of lateral-to-medial continuous transversus abdominis plane block with thoracic epidural analgesia in patients undergoing abdominal surgery: A randomised, open-label feasibility study.

    PubMed

    Ganapathy, Sugantha; Sondekoppam, Rakesh V; Terlecki, Magdalena; Brookes, Jonathan; Das Adhikary, Sanjib; Subramanian, Lakshmimathy

    2015-11-01

    We recently described a lateral-to-medial approach for transversus abdominis plane (LM-TAP) block, which may permit preoperative initiation of the block. Our objective was to evaluate the feasibility of continuous LM-TAP blocks in clinical practice in comparison with thoracic epidural analgesia (TEA). A randomised, open-label study. University Hospital, London Health Sciences Centre, London, Ontario, Canada from July 2008 to August 2012. Fifty adult patients undergoing open abdominal surgery via laparotomy were allocated randomly to receive preoperative catheter-congruent TEA or ultrasound-guided continuous bilateral LM-TAP block for 72 h postoperatively. Reasons for noninclusion were American Society of Anesthesiologists' physical status more than 4, known allergy to study drugs, chronic pain/opioid dependence, spinal abnormalities or psychiatric illness. In the TEA group (n = 24), patient-controlled epidural analgesia was maintained using bupivacaine 0.1% with hydromorphone 10 μg ml⁻¹ after establishment of the initial block. In the LM-TAP group (n = 26), ultrasound-guided LM-TAP catheters were inserted on each side preoperatively after a bolus of 30 ml of ropivacaine 0.5% (20 ml subcostal and 10 ml subumbilical injections on both sides). Analgesia was maintained with an infusion of ropivacaine 0.35% at a rate of 2 to 2.5 ml h⁻¹ through each catheter, along with rescue intravenous patient-controlled analgesia. The primary outcome was pain score on coughing 24 h after the end of surgery. Secondary outcomes were pain scores from 24 to 72 h, intraoperative and postoperative opioid consumption, time to onset of bowel movement and side effect profiles. Mean [95% confidence interval (95% CI)] pain scores at rest ranged from 1. 7 (0.9 to 2.5) to 2.3 (1.1 to 3.4) in TEA vs. 1.5 (0.7 to 2.2) to 2.2 (1.3 to 3.0) in LM-TAP (P = 0.829). The dynamic pain scores ranged from 2.9 (1.5 to 4.4) to 3.8 (2.8 to 4.8) in TEA vs. 3.3 (2.4 to 4.3) to 3.8 (2.7 to 4.9) in LM-TAP (P = 0.551). The variability in pain scores was lower in the LM-TAP group than in the TEA group in the first 24 h postoperatively. Patient satisfaction and other secondary outcomes were similar. Continuous bilateral LM-TAP block can be initiated preoperatively and may provide comparable analgesia to TEA in patients undergoing laparotomy. not registered because registration was not mandatory at the time of starting the trial.

  18. Ultrasound-guided fine needle aspiration versus core needle biopsy: comparison of post-biopsy hematoma rates and risk factors.

    PubMed

    Chae, In Hye; Kim, Eun-Kyung; Moon, Hee Jung; Yoon, Jung Hyun; Park, Vivian Y; Kwak, Jin Young

    2017-07-01

    To compare post-biopsy hematoma rates between ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy, and to investigate risk factors for post-biopsy hematoma. A total of 5304 thyroid nodules which underwent ultrasound guided biopsy were included in this retrospective study. We compared clinical and US features between patients with and without post-biopsy hematoma. Associations between these features and post-biopsy hematoma were analyzed. Post-biopsy hematoma rate was 0.8% (43/5121) for ultrasound guided-fine needle aspiration and 4.9% (9/183) for ultrasound guided-core needle biopsy (P < 0.001). For ultrasound guided-fine needle aspiration, gender, age, size, presence of vascularity, and suspicious US features were not associated with post-biopsy hematoma according to experience level. Post-biopsy hematoma occurred significantly more with ultrasound guided-core needle biopsy (9/179, 5.0%) than with ultrasound guided-fine needle aspiration (9/1138, 0.8%) (P < 0.001) in experienced performers and ultrasound guided-core needle biopsy was the only significant risk factor for post-biopsy hematoma (adjusted Odds Ratio, 6.458, P < 0.001). Post-biopsy hematoma occurred significantly more in ultrasound guided-core needle biopsy than in ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy was the only independent factor of post-biopsy hematoma in thyroid nodules.

  19. MR-guided Focused Ultrasound for Uterine Fibroids

    MedlinePlus

    ... Professions Site Index A-Z MR-guided Focused Ultrasound for Uterine Fibroids Magnetic Resonance-guided Focused Ultrasound ( ... are the limitations of MRgFUS? What is Focused Ultrasound of Uterine Fibroids? Magnetic Resonance-guided Focused Ultrasound ( ...

  20. Transverse vs torsional ultrasound: prospective randomized contralaterally controlled study comparing two phacoemulsification-system handpieces.

    PubMed

    Assil, Kerry K; Harris, Lindsay; Cecka, Jeannie

    2015-01-01

    To compare surgical efficiency and multiple early clinical outcome variables in eyes undergoing phacoemulsification using either transversal or torsional ultrasound systems. Assil Eye Institute, Beverly Hills, CA, USA. Prospective, randomized, clinician-masked, contralaterally controlled single-center evaluation. Patients seeking cataract removal in both eyes with implantation of multifocal intraocular lenses were randomly assigned to one of two treatment rooms for phacoemulsification with either a transverse ultrasound system or torsional handpiece system. The contralateral eye was treated at a later date with the alternate device. A total of 54 eyes of 27 patients having similar degrees of cataract, astigmatism, and visual potential were included. All operative data were collected for analysis, and patients were followed for 3 months after surgery. Similar visual acuity was reported at all postoperative visits between the two groups. Mean phacoemulsification time and total power required were both significantly lower with the transverse system than with the torsional technique (P<0.05 for both). Similarly, mean total balanced salt solution used was significantly less with the transverse system vs torsional (P<0.05). Postoperative safety demonstrated significantly lower endothelial cell loss at 1 day and 1 month (P<0.05) with transverse vs torsional. Macular swelling was less at 1 week, 1 month, and 3 months with transverse vs torsional, although the difference did not achieve significance (P=0.1) at any single time point. Clinically detectable corneal edema was reported less frequently at all postoperative time points with the transverse system. The transverse ultrasound system was found to be possibly associated with less balanced salt-solution use, less phacoemulsification time, and less power required than the torsional phaco system. Postoperative data suggested that improved phaco efficiency may translate to a better overall safety profile for the patient.

  1. Erector spinae plane block for analgesia after lower segment caesarean section: Case report.

    PubMed

    Yamak Altinpulluk, E; García Simón, D; Fajardo-Pérez, M

    2018-05-01

    Effective postoperative analgesia after emergency caesarean section is important because it provides early recovery, ambulation and breast-feeding. The ultrasound-guided erector spinae plane block has been orginally described for providing thoracic analgesia at the T5 transverse process by Forero et al. We performed post-operative bilateral erector spinae plane blocks with 20ml bupivacaine 0.25% at the level of the T9 transverse process in a pregnant woman after caesarean section. In this report, we described that bilateral erector spinae plane block at T9 level provides effective and long-lasting postoperative analgesia for lower abdominal surgery. Copyright © 2017 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  2. Technical Advances in Endoscopic Ultrasound (EUS)-Guided Tissue Acquisition for Pancreatic Cancers: How Can We Get the Best Results with EUS-Guided Fine Needle Aspiration?

    PubMed Central

    Kedia, Prashant; Gaidhane, Monica

    2013-01-01

    Endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) is one of the least invasive and most effective modality in diagnosing pancreatic adenocarcinoma in solid pancreatic lesions, with a higher diagnostic accuracy than cystic tumors. EUS-FNA has been shown to detect tumors less than 3 mm, due to high spatial resolution allowing the detection of very small lesions and vascular invasion, particularly in the pancreatic head and neck, which may not be detected on transverse computed tomography. Furthermore, this minimally invasive procedure is often ideal in the endoscopic procurement of tissue in patients with unresectable tumors. While EUS-FNA has been increasingly used as a diagnostic tool, most studies have collectively looked at all primary pancreatic solid lesions, including lymphomas and pancreatic neuroendocrine neoplasms, whereas very few studies have examined the diagnostic utility of EUS-FNA of pancreatic ductal carcinoma only. As with any novel and advanced endoscopic procedure that may incorporate several practices and approaches, endoscopists have adopted diverse techniques to improve the tissue procurement practice and increase diagnostic accuracy. In this article, we present a review of literature to date and discuss currently practiced EUS-FNA technique, including indications, technical details, equipment, patient selection, and diagnostic accuracy. PMID:24143320

  3. Ultrasound guided reduction of an ileocolic intussusception by a hydrostatic method by using normal saline enema in paediatric patients: a study of 30 cases.

    PubMed

    Digant, Shastri Mona; Rucha, Seth; Eke, Dessai

    2012-12-01

    The conventional hydrostatic reduction of an intussusception with barium enema or the pneumatic reduction of an intussusception is associated with considerable ionizing radiations and a risk of perforation; while the hydrostatic reduction of an intussusception under ultrasound guidance is a very safe method because the whole procedure is visualized with real time ultrasound. Also, being a non-invasive method with a high success rate, this procedure has emerged as a useful alternative to a surgical intervention. The aim of this study was to evaluate the role of ultrasound and colour Doppler studies for the guidance of the hydrostatic reduction of a childhood intussusception by using normal saline. Among 41 children who were evaluated with ultrasonography for the confirmation of the presence of intussusceptions, hydrostatic reduction of intussusception were performed under a sonographic guidance in 30 patients, whereas 11 patients were excluded due to clinical contraindications. This disease was observed mostly at the ages of 6 months to 24 months. In 80% of the patients, there was a recent history of gastroenteritis and 40 % had a history of common cold. The most common site of the intussusception was the transverse colon near the hepatic flexor of the colon (90%), with a mean duration of 22.1±17.3 hours. The overall rate of a successful reduction was 87% and the mean reduction time was 14 minutes. None of the cases showed recurrence within 24 hrs. No complications were observed. We conclude that ultrasound with colour Doppler study is very useful for the diagnosis of intussusceptions, as well as for guided hydrostatic reductions by using normal saline enema. This is an optimal, simple, and a safe procedure for the treatment of intussusceptions in paediatric patients.

  4. Double Back Cut in Post-mastectomy Breast Skin (Fish-Shaped Skin Paddle) in Delayed Pedicled TRAM Flap Breast Reconstruction.

    PubMed

    Berezovsky, Alexander Bogdanov; Pagkalos, Vasileios A; Shoham, Yaron; Krieger, Yuval; Silberstein, Eldad

    2015-08-01

    Breast reconstruction has become standard of care for female patients with breast cancer. The transverse rectus abdominis musculo-cutaneous flap (TRAMf) is the most common method of immediate or delayed autologous breast reconstruction following mastectomy. We share our experience with modified, double back cut of post-mastectomy skin in delayed pedicled TRAMf breast reconstruction, resulting in fish-shaped skin paddle. This sort of back cut is a simple, reliable way to obtain a natural, esthetically pleasant breast mound with inconspicuous hidden scars.

  5. Measurement of the normalized broadband ultrasound attenuation in trabecular bone by using a bidirectional transverse transmission technique

    NASA Astrophysics Data System (ADS)

    Lee, Kang Il

    2015-01-01

    A new method for measuring the normalized broadband ultrasound attenuation (nBUA) in trabecular bone by using a bidirectional transverse transmission technique was proposed and validated with measurements obtained by using the conventional transverse transmission technique. There was no significant difference between the nBUA measurements obtained for 14 bovine femoral trabecular bone samples by using the bidirectional and the conventional transverse transmission techniques. The nBUA measured by using the two transverse transmission techniques showed strong positive correlations of r = 0.87 to 0.88 with the apparent bone density, consistent with the behavior in human trabecular bone invitro. We expect that the new method can be usefully applied for improved accuracy and precision in clinical measurements.

  6. Clinical workflow for spinal curvature measurement with portable ultrasound

    NASA Astrophysics Data System (ADS)

    Tabanfar, Reza; Yan, Christina; Kempston, Michael; Borschneck, Daniel; Ungi, Tamas; Fichtinger, Gabor

    2016-03-01

    PURPOSE: Spinal curvature monitoring is essential in making treatment decisions in scoliosis. Monitoring entails radiographic examinations, however repeated ionizing radiation exposure has been shown to increase cancer risk. Ultrasound does not emit ionizing radiation and is safer for spinal curvature monitoring. We investigated a clinical sonography protocol and challenges associated with position-tracked ultrasound in spinal curvature measurement in scoliosis. METHODS: Transverse processes were landmarked along each vertebra using tracked ultrasound snapshots. The transverse process angle was used to determine the orientation of each vertebra. We tested our methodology on five patients in a local pediatric scoliosis clinic, comparing ultrasound to radiographic curvature measurements. RESULTS: Despite strong correlation between radiographic and ultrasound curvature angles in phantom studies, we encountered new challenges in the clinical setting. Our main challenge was differentiating transverse processes from ribs and other structures during landmarking. We observed up to 13° angle variability for a single vertebra and a 9.85° +/- 10.81° difference between ultrasound and radiographic Cobb angles for thoracic curvatures. Additionally, we were unable to visualize anatomical landmarks in the lumbar region where soft tissue depth was 25-35mm. In volunteers with large Cobb angles (greater than 40° thoracic and 60° lumbar), we observed spinal protrusions resulting in incomplete probe-skin contact and partial ultrasound images not suitable for landmarking. CONCLUSION: Spinal curvature measurement using tracked ultrasound is viable on phantom spine models. In the clinic, new challenges were encountered which must be resolved before a universal sonography protocol can be developed.

  7. Transverse vs torsional ultrasound: prospective randomized contralaterally controlled study comparing two phacoemulsification-system handpieces

    PubMed Central

    Assil, Kerry K; Harris, Lindsay; Cecka, Jeannie

    2015-01-01

    Purpose To compare surgical efficiency and multiple early clinical outcome variables in eyes undergoing phacoemulsification using either transversal or torsional ultrasound systems. Setting Assil Eye Institute, Beverly Hills, CA, USA. Design Prospective, randomized, clinician-masked, contralaterally controlled single-center evaluation. Patients and methods Patients seeking cataract removal in both eyes with implantation of multifocal intraocular lenses were randomly assigned to one of two treatment rooms for phacoemulsification with either a transverse ultrasound system or torsional handpiece system. The contralateral eye was treated at a later date with the alternate device. A total of 54 eyes of 27 patients having similar degrees of cataract, astigmatism, and visual potential were included. All operative data were collected for analysis, and patients were followed for 3 months after surgery. Results Similar visual acuity was reported at all postoperative visits between the two groups. Mean phacoemulsification time and total power required were both significantly lower with the transverse system than with the torsional technique (P<0.05 for both). Similarly, mean total balanced salt solution used was significantly less with the transverse system vs torsional (P<0.05). Postoperative safety demonstrated significantly lower endothelial cell loss at 1 day and 1 month (P<0.05) with transverse vs torsional. Macular swelling was less at 1 week, 1 month, and 3 months with transverse vs torsional, although the difference did not achieve significance (P=0.1) at any single time point. Clinically detectable corneal edema was reported less frequently at all postoperative time points with the transverse system. Conclusion The transverse ultrasound system was found to be possibly associated with less balanced salt-solution use, less phacoemulsification time, and less power required than the torsional phaco system. Postoperative data suggested that improved phaco efficiency may translate to a better overall safety profile for the patient. PMID:26345628

  8. [Pancreatic tail pseudoaneurysm: percutaneous treatment by thrombin injection].

    PubMed

    Pacheco Jiménez, M; Moreno Sánchez, T; Moreno Rodríguez, F; Guillén Rico, M

    2014-01-01

    Visceral artery pseudoaneurysms secondary to acute and/or chronic pancreatitis are a relatively common and potentially serious complication. Endovascular techniques are the most currently accepted techniques, given the higher morbidity-mortality of surgery. The thrombosis of the pseudoaneurysm using an ultrasound-guided percutaneous thrombin injection is emerging as a useful option in those cases in which endovascular embolisation is not possible. We present the case of a patient with a pseudoaneurysm of the transverse pancreatic artery secondary to chronic pancreatitis, and successfully treated by administering percutaneous thrombin. Copyright © 2011 SERAM. Published by Elsevier Espana. All rights reserved.

  9. Low back and hip pain in a postpartum runner: applying ultrasound imaging and running analysis.

    PubMed

    Thein-Nissenbaum, Jill M; Thompson, Elizabeth F; Chumanov, Elizabeth S; Heiderscheit, Bryan C

    2012-07-01

    Case report. Postpartum low back and hip dysfunction may be caused by an incomplete recovery of abdominal musculature and impaired neuromuscular control. The purpose of this report is to describe the management of a postpartum runner with hip and low back pain through exercise training via ultrasound imaging (USI) biofeedback combined with running-form modification. A postpartum runner with hip and low back pain underwent dynamic lumbar stabilization training with USI biofeedback and running-form modification to reduce mechanical loading. Muscle thickness of transversus abdominis and internal oblique was measured with USI preintervention and 7 weeks after completion of the intervention. Additionally, 3-dimensional lower extremity joint motions, moments, and powers were calculated during treadmill running. The patient's pain with running decreased from a constant 9/10 (0, no pain; 10, worst pain) to an occasional 3/10 posttreatment. Transversus abdominis muscle thickness increased 6.3% during the abdominal drawing-in maneuver and 27.0% during the abdominal drawing-in maneuver with straight leg raise. Changes were also noted in the internal oblique. These findings corresponded to improved lumbopelvic control: pelvic list and axial rotation during running decreased 38% and 36%, respectively. The patient's running volume returned to preinjury levels (8.1-9.7 km, 3 days per week) with no hip pain and minimal low back pain, and she successfully completed her goal of running a half-marathon. The successful outcomes of this case support the consideration of dynamic lumbar stabilization exercises, USI biofeedback, and running-form modification in postpartum runners with lumbopelvic dysfunction. Therapy, level 4.

  10. The Deep Inferior Epigastric Perforator and Pedicled Transverse Rectus Abdominis Myocutaneous Flap in Breast Reconstruction: A Comparative Study

    PubMed Central

    Tan, Shane; Yek, Jacklyn; Ong, Wei Chen; Hing, Chor Hoong; Lim, Thiam Chye

    2013-01-01

    Background Our objective was to compare the complication rates of two common breast reconstruction techniques performed at our hospital and the cost-effectiveness for each test group. Methods All patients who underwent deep inferior epigastric perforator (DIEP) flap and transverse rectus abdominis myocutaneous (TRAM) flap by the same surgeon were selected and matched according to age and mastectomy with or without axillary clearance. Patients from each resultant group were selected, with the patients matched chronologically. The remainder were matched for by co-morbidities. Sixteen patients who underwent immediate breast reconstruction with pedicled TRAM flaps and 16 patients with DIEP flaps from 1999 to 2006 were accrued. The average total hospitalisation cost, length of hospitalisation, and complications in the 2 year duration after surgery for each group were compared. Results Complications arising from both the pedicled TRAM flaps and DIEP flaps included fat necrosis (TRAM, 3/16; DIEP, 4/16) and other minor complications (TRAM, 3/16; DIEP, 1/16). The mean hospital stay was 7.13 days (range, 4 to 12 days) for the pedicled TRAM group and 7.56 (range, 5 to 10 days) for the DIEP group. Neither the difference in complication rates nor in hospital stay duration were statistically significant. The total hospitalisation cost for the DIEP group was significantly higher than that of the pedicled TRAM group (P<0.001). Conclusions Based on our study, the pedicled TRAM flap remains a cost-effective technique in breast reconstruction when compared to the newer, more expensive and tedious DIEP flap. PMID:23730591

  11. The Impact of Perioperative Hormonal Therapy for Breast Cancer on Transverse Rectus Abdominis Myocutaneous Flap Abdominal Complications.

    PubMed

    Huber, Katherine M; Clayman, Eric; Kumar, Ambuj; Smith, Paul

    2018-06-01

    The pedicled transverse rectus abdominis myocutaneous (TRAM) flap is a reliable reconstructive option in breast cancer patients; however, it carries known risk of donor site hernia formation. Some hormonal therapy drugs have been associated with hernia formation in animal models. Minimal data exist concerning impact of hormonal therapy for breast cancer on abdominal donor site complications after breast reconstruction. Patients who underwent TRAM flap for breast cancer or high-risk status at a single institution by the senior author from 2003 to 2015 were identified. Charts were reviewed. Patient demographics, comorbidities, treatments, and abdominal complications were recorded. Patients were divided into groups based on use of hormonal therapy as well as exposure to specific drugs. Statistical analyses were performed. A total of 358 patients were included. Overall hernia rate was 5.9%. About 231 (64.5%) patients had hormonal therapy, whereas 127 (35.5%) did not. Difference in hernia formation was not statistically significant between the hormonal therapy group (6.9%) and the no hormonal therapy group (3.9%; P = 0.359). Patients exposed to tamoxifen and those exposed to anastrozole had no significant difference in complication rates compared with the no hormonal therapy group, whereas patients exposed to letrozole had increased rate of hernia (13.5%; P = 0.037) and infection (21.6%; P = 0.013) compared with the no hormonal therapy group (3.9% and 7.1%, respectively). Hormonal therapy is a useful adjunct for chemoprevention in breast cancer; however, use of letrozole in patients undergoing reconstruction with pedicled TRAM can lead to increase in certain complication rates.

  12. Bedside ultrasound training using web-based e-learning and simulation early in the curriculum of residents.

    PubMed

    Beaulieu, Yanick; Laprise, Réjean; Drolet, Pierre; Thivierge, Robert L; Serri, Karim; Albert, Martin; Lamontagne, Alain; Bélliveau, Marc; Denault, André-Yves; Patenaude, Jean-Victor

    2015-01-01

    Focused bedside ultrasound is rapidly becoming a standard of care to decrease the risks of complications related to invasive procedures. The purpose of this study was to assess whether adding to the curriculum of junior residents an educational intervention combining web-based e-learning and hands-on training would improve the residents' proficiency in different clinical applications of bedside ultrasound as compared to using the traditional apprenticeship teaching method alone. Junior residents (n = 39) were provided with two educational interventions (vascular and pleural ultrasound). Each intervention consisted of a combination of web-based e-learning and bedside hands-on training. Senior residents (n = 15) were the traditionally trained group and were not provided with the educational interventions. After the educational intervention, performance of the junior residents on the practical tests was superior to that of the senior residents. This was true for the vascular assessment (94% ± 5% vs. 68% ± 15%, unpaired student t test: p < 0.0001, mean difference: 26 (95% CI: 20 to 31)) and even more significant for the pleural assessment (92% ± 9% vs. 57% ± 25%, unpaired student t test: p < 0.0001, mean difference: 35 (95% CI: 23 to 44)). The junior residents also had a significantly higher success rate in performing ultrasound-guided needle insertion compared to the senior residents for both the transverse (95% vs. 60%, Fisher's exact test p = 0.0048) and longitudinal views (100% vs. 73%, Fisher's exact test p = 0.0055). Our study demonstrated that a structured curriculum combining web-based education, hands-on training, and simulation integrated early in the training of the junior residents can lead to better proficiency in performing ultrasound-guided techniques compared to the traditional apprenticeship model.

  13. [Comparison of transverse short-axis classic and oblique long-axis "Syringe-Free" approaches for internal jugular venous catheterization under ultrasound guidance].

    PubMed

    Ince, Ilker; Arı, Muhammet Ali; Sulak, Muhammet Mustafa; Aksoy, Mehmet

    There are different ultrasound probe positions used for internal jugular venous catheter placement. Also, in-plane or out of plane needle approach may be used for catheterization. Transverse short-axis classic approach is the most popular performed approach in literature. "Syringe-Free" is a new described technique that is performed with oblique long-axis approach. We aimed to compare performance of these two approaches. This study was conducted as a prospective and randomized study. 80 patients were included the study and divided into two groups that were named Group C (transverse short-axis classic approach) and Group SF (oblique long-axis syringe-free approach) by a computer-generated randomization. The primary outcome was mean time that guidewire is seen in the internal jugular vein (performing time). The secondary outcomes were to compare number of needle pass, number of skin puncture and complications between two groups. Demographic and hemodynamic data were not significantly different. The mean performing time was 54.9±19.1s in Group C and 43.9±15.8s in Group SF. Significant differences were found between the groups (p=0.006). Mean number of needle pass was 3.2(±2.1) in Group C and 2.1(±1.6) in Group SF. There were statistically significant differences between two groups (p=0.002). The number of skin puncture was 1.6(±0.8) and 1.2(±0.5) in Group C and SF, respectively (p=0.027). "Syringe-Free" technique has lower performing time, number of needle pass and skin puncture. Also, it allows to follow progress of guide-wire under continuous ultrasound visualization and the procedure does not need assistance during catheter insertion. Namely, "Syringe-Free" is effective, safe and fast technique that may be used to place internal jugular venous catheter. Copyright © 2017 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All rights reserved.

  14. Reliability of measuring sciatic and tibial nerve movement with diagnostic ultrasound during a neural mobilisation technique.

    PubMed

    Ellis, Richard; Hing, Wayne; Dilley, Andrew; McNair, Peter

    2008-08-01

    Diagnostic ultrasound provides a technique whereby real-time, in vivo analysis of peripheral nerve movement is possible. This study measured sciatic nerve movement during a "slider" neural mobilisation technique (ankle dorsiflexion/plantar flexion and cervical extension/flexion). Transverse and longitudinal movement was assessed from still ultrasound images and video sequences by using frame-by-frame cross-correlation software. Sciatic nerve movement was recorded in the transverse and longitudinal planes. For transverse movement, at the posterior midthigh (PMT) the mean value of lateral sciatic nerve movement was 3.54 mm (standard error of measurement [SEM] +/- 1.18 mm) compared with anterior-posterior/vertical (AP) movement of 1.61 mm (SEM +/- 0.78 mm). At the popliteal crease (PC) scanning location, lateral movement was 6.62 mm (SEM +/- 1.10 mm) compared with AP movement of 3.26 mm (SEM +/- 0.99 mm). Mean longitudinal sciatic nerve movement at the PMT was 3.47 mm (SEM +/- 0.79 mm; n = 27) compared with the PC of 5.22 mm (SEM +/- 0.05 mm; n = 3). The reliability of ultrasound measurement of transverse sciatic nerve movement was fair to excellent (Intraclass correlation coefficient [ICC] = 0.39-0.76) compared with excellent (ICC = 0.75) for analysis of longitudinal movement. Diagnostic ultrasound presents a reliable, noninvasive, real-time, in vivo method for analysis of sciatic nerve movement.

  15. Transversus abdominis plane block in renal allotransplant recipients: A retrospective chart review.

    PubMed

    Gopwani, S R; Rosenblatt, M A

    2016-01-01

    The efficacy of the transversus abdominis plane (TAP) block appears to vary considerably, depending on the surgical procedure and block technique. This study aims to add to the existing literature and provide a more clear understanding of the TAP blocks role as a postoperative analgesic technique, specifically in renal allotransplant recipients. A retrospective chart review was conducted by querying the intraoperative electronic medical record system of a 1200-bed tertiary academic hospital over a 5 months period, and reviewing anesthetic techniques, as well as postoperative morphine equivalent consumption. Fifty renal allotransplant recipients were identified, 13 of whom received TAP blocks while 37 received no regional analgesic technique. All blocks were performed under ultrasound guidance, with 20 mL of 0.25% bupivacaine injected in the transversus abdominis fascial plane under direct visualization. The primary outcome was postoperative morphine equivalent consumption. Morphine consumption was compared with the two-tailed Mann-Whitney U -test. Continuous variables of patient baseline characteristics were analyzed with unpaired t -test and categorical variables with Fischer Exact Test. A P < 0.05 was considered statistically significant. A statistically significant decrease in cumulative morphine consumption was found in the group that received the TAP block at 6 h (2.46 mg vs. 7.27 mg, P = 0.0010), 12 h (3.88 mg vs. 10.20 mg, P = 0.0005), 24 h (6.96 mg vs. 14.75 mg, P = 0.0013), and 48 h (11 mg vs. 20.13 mg, P = 0.0092). The TAP block is a beneficial postoperative analgesic, opiate-sparing technique in renal allotransplant recipients.

  16. The Feasibility of Integrating Elastography Measurements into MRI-Guided Transurethral Ultrasound Therapy

    NASA Astrophysics Data System (ADS)

    Arani, Arvin; Huang, Yuexi; Bronskill, Michael; Chopra, Rajiv

    2009-04-01

    MRI-guided transurethral ultrasound therapy is being developed as a minimally invasive treatment for localized prostate cancer. The capability to identify target regions prior to therapy would provide an integrated diagnostic and therapeutic solution to the management of this disease. The objective of this project is to evaluate the feasibility of performing elastography using a transurethral actuator. Shear waves were generated in the prostate by vibrating the transurethral actuator longitudinally and resolving the tissue displacements with a 1.5 Tesla MRI. A piezoelectric actuator was used to vibrate the transurethral device with an amplitude of 32 um at frequencies of 100 and 250 Hz. GRE imaging sequences with displacement encoded along the direction of vibration were acquired transverse and parallel to the rod to visualize the dynamics of wave propagation. Experiments were performed in phantoms (8% gelatin) and in a canine model (n = 5). Vibration was achieved in the MRI without significant loss of SNR in the images. The shear waves produced in the gel were cylindrical in nature, and extended along the length of the rod. Shear wave propagation in the canine prostate gland was observed at 100 and 250 Hz, and shear modulus values agreed with previously published values.

  17. Brachial artery vasomotion and transducer pressure effect on measurements by active contour segmentation on ultrasound

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cary, Theodore W.; Sultan, Laith R.; Sehgal, Chandra M., E-mail: sehgalc@uphs.upenn.edu

    Purpose: To use feed-forward active contours (snakes) to track and measure brachial artery vasomotion on ultrasound images recorded in both transverse and longitudinal views; and to compare the algorithm's performance in each view. Methods: Longitudinal and transverse view ultrasound image sequences of 45 brachial arteries were segmented by feed-forward active contour (FFAC). The segmented regions were used to measure vasomotion artery diameter, cross-sectional area, and distention both as peak-to-peak diameter and as area. ECG waveforms were also simultaneously extracted frame-by-frame by thresholding a running finite-difference image between consecutive images. The arterial and ECG waveforms were compared as they traced eachmore » phase of the cardiac cycle. Results: FFAC successfully segmented arteries in longitudinal and transverse views in all 45 cases. The automated analysis took significantly less time than manual tracing, but produced superior, well-behaved arterial waveforms. Automated arterial measurements also had lower interobserver variability as measured by correlation, difference in mean values, and coefficient of variation. Although FFAC successfully segmented both the longitudinal and transverse images, transverse measurements were less variable. The cross-sectional area computed from the longitudinal images was 27% lower than the area measured from transverse images, possibly due to the compression of the artery along the image depth by transducer pressure. Conclusions: FFAC is a robust and sensitive vasomotion segmentation algorithm in both transverse and longitudinal views. Transverse imaging may offer advantages over longitudinal imaging: transverse measurements are more consistent, possibly because the method is less sensitive to variations in transducer pressure during imaging.« less

  18. Brachial artery vasomotion and transducer pressure effect on measurements by active contour segmentation on ultrasound.

    PubMed

    Cary, Theodore W; Reamer, Courtney B; Sultan, Laith R; Mohler, Emile R; Sehgal, Chandra M

    2014-02-01

    To use feed-forward active contours (snakes) to track and measure brachial artery vasomotion on ultrasound images recorded in both transverse and longitudinal views; and to compare the algorithm's performance in each view. Longitudinal and transverse view ultrasound image sequences of 45 brachial arteries were segmented by feed-forward active contour (FFAC). The segmented regions were used to measure vasomotion artery diameter, cross-sectional area, and distention both as peak-to-peak diameter and as area. ECG waveforms were also simultaneously extracted frame-by-frame by thresholding a running finite-difference image between consecutive images. The arterial and ECG waveforms were compared as they traced each phase of the cardiac cycle. FFAC successfully segmented arteries in longitudinal and transverse views in all 45 cases. The automated analysis took significantly less time than manual tracing, but produced superior, well-behaved arterial waveforms. Automated arterial measurements also had lower interobserver variability as measured by correlation, difference in mean values, and coefficient of variation. Although FFAC successfully segmented both the longitudinal and transverse images, transverse measurements were less variable. The cross-sectional area computed from the longitudinal images was 27% lower than the area measured from transverse images, possibly due to the compression of the artery along the image depth by transducer pressure. FFAC is a robust and sensitive vasomotion segmentation algorithm in both transverse and longitudinal views. Transverse imaging may offer advantages over longitudinal imaging: transverse measurements are more consistent, possibly because the method is less sensitive to variations in transducer pressure during imaging.

  19. Brachial artery vasomotion and transducer pressure effect on measurements by active contour segmentation on ultrasound

    PubMed Central

    Cary, Theodore W.; Reamer, Courtney B.; Sultan, Laith R.; Mohler, Emile R.; Sehgal, Chandra M.

    2014-01-01

    Purpose: To use feed-forward active contours (snakes) to track and measure brachial artery vasomotion on ultrasound images recorded in both transverse and longitudinal views; and to compare the algorithm's performance in each view. Methods: Longitudinal and transverse view ultrasound image sequences of 45 brachial arteries were segmented by feed-forward active contour (FFAC). The segmented regions were used to measure vasomotion artery diameter, cross-sectional area, and distention both as peak-to-peak diameter and as area. ECG waveforms were also simultaneously extracted frame-by-frame by thresholding a running finite-difference image between consecutive images. The arterial and ECG waveforms were compared as they traced each phase of the cardiac cycle. Results: FFAC successfully segmented arteries in longitudinal and transverse views in all 45 cases. The automated analysis took significantly less time than manual tracing, but produced superior, well-behaved arterial waveforms. Automated arterial measurements also had lower interobserver variability as measured by correlation, difference in mean values, and coefficient of variation. Although FFAC successfully segmented both the longitudinal and transverse images, transverse measurements were less variable. The cross-sectional area computed from the longitudinal images was 27% lower than the area measured from transverse images, possibly due to the compression of the artery along the image depth by transducer pressure. Conclusions: FFAC is a robust and sensitive vasomotion segmentation algorithm in both transverse and longitudinal views. Transverse imaging may offer advantages over longitudinal imaging: transverse measurements are more consistent, possibly because the method is less sensitive to variations in transducer pressure during imaging. PMID:24506648

  20. Quadratus lumborum catheters for breast reconstruction requiring transverse rectus abdominis myocutaneous flaps.

    PubMed

    Spence, Nicole Z; Olszynski, Patrycja; Lehan, Anne; Horn, Jean-Lois; Webb, Christopher A J

    2016-06-01

    Patients diagnosed with breast cancer may opt to undergo surgical reconstructive flaps at the time of or after mastectomies. These surgeries leave patients with significant postoperative pain and sometimes involve large surgical beds including graft sites from the abdomen to reconstruct the breast. Consequently, multimodal methods of pain management have become highly favored. Quadratus lumborum catheters offer an opioid-sparing technique that can be performed easily and safely. We present a case of a patient who underwent a breast flap reconstruction and had bilateral quadratus lumborum catheters placed for perioperative pain control.

  1. The putative involvement of the transabdominal muscles in dysphonia: a preliminary study and thoughts.

    PubMed

    Rubin, J S; Macdonald, I; Blake, E

    2011-03-01

    Real-time ultrasound was used as an adjunct to assess patterns of periabdominal musculature in 14 individual with dysphonia and muscle tension dysphonia. Fourteen individuals with muscle tension dysphonia were evaluated with real-time ultrasound as a part of their initial evaluation and management. In 13 of 14 individuals, there was an imbalance found during phonation between the transversus abdominis muscles (TAs) and internal oblique muscles (IOs), whereby the IOs were found to be overactive and the TAs underactive. After physiotherapy, this pattern was reversed. The abdominal muscle pattern of overactivity of the internal oblique and underactivity of the TA during phonation was found to be present in the large majority of patients in this pilot sample who had presented with muscle tension dysphonia. The significance of this is unclear but deserves further review. Copyright © 2011 The Voice Foundation. Published by Mosby, Inc. All rights reserved.

  2. Ultrasound guided double injection of blood into cisterna magna: a rabbit model for treatment of cerebral vasospasm.

    PubMed

    Chen, Yongchao; Zhu, Youzhi; Zhang, Yu; Zhang, Zixuan; Lian, Juan; Luo, Fucheng; Deng, Xuefei; Wong, Kelvin K L

    2016-02-06

    Double injection of blood into cisterna magna using a rabbit model results in cerebral vasospasm. An unacceptably high mortality rate tends to limit the application of model. Ultrasound guided puncture can provide real-time imaging guidance for operation. The aim of this paper is to establish a safe and effective rabbit model of cerebral vasospasm after subarachnoid hemorrhage with the assistance of ultrasound medical imaging. A total of 160 New Zealand white rabbits were randomly divided into four groups of 40 each: (1) manual control group, (2) manual model group, (3) ultrasound guided control group, and (4) ultrasound guided model group. The subarachnoid hemorrhage was intentionally caused by double injection of blood into their cisterna magna. Then, basilar artery diameters were measured using magnetic resonance angiography before modeling and 5 days after modeling. The depth of needle entering into cisterna magna was determined during the process of ultrasound guided puncture. The mortality rates in manual control group and model group were 15 and 23 %, respectively. No rabbits were sacrificed in those two ultrasound guided groups. We found that the mortality rate in ultrasound guided groups decreased significantly compared to manual groups. Compared with diameters before modeling, the basilar artery diameters after modeling were significantly lower in manual and ultrasound guided model groups. The vasospasm aggravated and the proportion of severe vasospasms was greater in ultrasound guided model group than that of manual group. In manual model group, no vasospasm was found in 8 % of rabbits. The ultrasound guided double injection of blood into cisterna magna is a safe and effective rabbit model for treatment of cerebral vasospasm.

  3. Comparison of deep and superficial abdominal muscle activity between experienced Pilates and resistance exercise instructors and controls during stabilization exercise.

    PubMed

    Moon, Ji-Hyun; Hong, Sang-Min; Kim, Chang-Won; Shin, Yun-A

    2015-06-01

    Pilates and resistance exercises are used for lumbar stabilization training. However, it is unclear which exercise is more effective for lumbar stabilization. In our study, we aimed to compare surface muscle activity and deep muscle thickness during relaxation and spinal stabilization exercise in experienced Pilates and resistance exercise instructors. This study is a retrospective case control study set in the Exercise Prescription Laboratory and Sports Medicine Center. The participants included Pilates instructors (mean years of experience, 3.20±1.76; n=10), resistance exercise instructors (mean years of experience, 2.53±0.63; n=10), and controls (n=10). The participants performed 4 different stabilization exercises: abdominal drawing-in maneuver, bridging, roll-up, and one-leg raise. During the stabilization exercises, surface muscle activity was measured with electromyography, whereas deep muscle thickness was measured by ultrasound imaging. During the 4 stabilization exercises, the thickness of the transverse abdominis (TrA) was significantly greater in the Pilates-trained group than the other 2 other groups. The internal oblique (IO) thickness was significantly greater in the Pilates- and resistance-trained group than the control group, during the 4 exercises. However, the surface muscle activities were similar between the groups. Both Pilates and resistance exercise instructors had greater activation of deep muscles, such as the TrA and IO, than the control subjects. Pilates and resistance exercise are both effective for increasing abdominal deep muscle thickness.

  4. Comparison of deep and superficial abdominal muscle activity between experienced Pilates and resistance exercise instructors and controls during stabilization exercise

    PubMed Central

    Moon, Ji-Hyun; Hong, Sang-Min; Kim, Chang-Won; Shin, Yun-A

    2015-01-01

    Pilates and resistance exercises are used for lumbar stabilization training. However, it is unclear which exercise is more effective for lumbar stabilization. In our study, we aimed to compare surface muscle activity and deep muscle thickness during relaxation and spinal stabilization exercise in experienced Pilates and resistance exercise instructors. This study is a retrospective case control study set in the Exercise Prescription Laboratory and Sports Medicine Center. The participants included Pilates instructors (mean years of experience, 3.20±1.76; n=10), resistance exercise instructors (mean years of experience, 2.53±0.63; n=10), and controls (n=10). The participants performed 4 different stabilization exercises: abdominal drawing-in maneuver, bridging, roll-up, and one-leg raise. During the stabilization exercises, surface muscle activity was measured with electromyography, whereas deep muscle thickness was measured by ultrasound imaging. During the 4 stabilization exercises, the thickness of the transverse abdominis (TrA) was significantly greater in the Pilates-trained group than the other 2 other groups. The internal oblique (IO) thickness was significantly greater in the Pilates- and resistance-trained group than the control group, during the 4 exercises. However, the surface muscle activities were similar between the groups. Both Pilates and resistance exercise instructors had greater activation of deep muscles, such as the TrA and IO, than the control subjects. Pilates and resistance exercise are both effective for increasing abdominal deep muscle thickness. PMID:26171383

  5. Sonoanatomical Change of Phrenic Nerve According to Posture During Ultrasound-Guided Stellate Ganglion Block

    PubMed Central

    Joeng, Eui Soo; Jeong, Young Cheol; Park, Bum Jun; Kang, Seok; Yang, Seung Nam

    2016-01-01

    Objective To evaluate the risk of phrenic nerve injury during ultrasound-guided stellate ganglion block (US-SGB) according to sonoanatomy of the phrenic nerve, and determine a safer posture for needle insertion by assessing its relationship with surrounding structure according to positional change. Methods Twenty-nine healthy volunteers were recruited and underwent ultrasound in two postures, i.e., supine position with the neck extension and head rotation, and lateral decubitus position. The transducer was placed at the anterior tubercle of the C6 level to identify phrenic nerve. The cross-sectional area (CSA), depth from skin, distance between phrenic nerve and anterior tubercle of C6 transverse process, and the angle formed by anterior tubercle, posterior tubercle and phrenic nerve were measured. Results The phrenic nerve was clearly identified in the intermuscular fascia layer between the anterior scalene and sternocleidomastoid muscles. The distance between the phrenic nerve and anterior tubercle was 10.33±3.20 mm with the supine position and 9.20±3.31 mm with the lateral decubitus position, respectively. The mean CSA and skin depth of phrenic nerve were not statistically different between the two positions. The angle with the supine position was 48.37°±27.43°, and 58.89°±30.02° with the lateral decubitus position. The difference of angle between the two positions was statistically significant. Conclusion Ultrasound is a useful tool for assessing the phrenic nerve and its anatomical relation with other cervical structures. In addition, lateral decubitus position seems to be safer by providing wider angle for needle insertion than the supine position in US-SGB. PMID:27152274

  6. Sonoanatomical Change of Phrenic Nerve According to Posture During Ultrasound-Guided Stellate Ganglion Block.

    PubMed

    Joeng, Eui Soo; Jeong, Young Cheol; Park, Bum Jun; Kang, Seok; Yang, Seung Nam; Yoon, Joon Shik

    2016-04-01

    To evaluate the risk of phrenic nerve injury during ultrasound-guided stellate ganglion block (US-SGB) according to sonoanatomy of the phrenic nerve, and determine a safer posture for needle insertion by assessing its relationship with surrounding structure according to positional change. Twenty-nine healthy volunteers were recruited and underwent ultrasound in two postures, i.e., supine position with the neck extension and head rotation, and lateral decubitus position. The transducer was placed at the anterior tubercle of the C6 level to identify phrenic nerve. The cross-sectional area (CSA), depth from skin, distance between phrenic nerve and anterior tubercle of C6 transverse process, and the angle formed by anterior tubercle, posterior tubercle and phrenic nerve were measured. The phrenic nerve was clearly identified in the intermuscular fascia layer between the anterior scalene and sternocleidomastoid muscles. The distance between the phrenic nerve and anterior tubercle was 10.33±3.20 mm with the supine position and 9.20±3.31 mm with the lateral decubitus position, respectively. The mean CSA and skin depth of phrenic nerve were not statistically different between the two positions. The angle with the supine position was 48.37°±27.43°, and 58.89°±30.02° with the lateral decubitus position. The difference of angle between the two positions was statistically significant. Ultrasound is a useful tool for assessing the phrenic nerve and its anatomical relation with other cervical structures. In addition, lateral decubitus position seems to be safer by providing wider angle for needle insertion than the supine position in US-SGB.

  7. Trunk extensor muscle fatigue influences trunk muscle activities.

    PubMed

    Hoseinpoor, Tahere Seyed; Kahrizi, Sedighe; Mobini, Bahram

    2015-01-01

    Trunk muscles fatigue is one of the risk factors in workplaces and daily activities. Loads would be redistributed among active and passive tissues in a non-optimal manner in fatigue conditions. Therefore, a single tissue might be overloaded with minimal loads and as a result the risk of injury would increase. The goal of this paper was to assess the electromyographic response of trunk extensor and abdominal muscles after trunk extensor muscles fatigue induced by cyclic lifting task. This was an experimental study that twenty healthy women participated. For assessing automatic response of trunk extensor and abdominal muscles before and after the fatigue task, electromyographic activities of 6 muscles: thorasic erector spine (TES), lumbar erector spine (LES), lumbar multifidus (LMF), transverse abdominis/ internal oblique (TrA/IO), rectus abdominis (RA) and external oblique (EO) were recorded in standing position with no load and symmetric axial loads equal to 25% of their body weights. Statistical analysis showed that all the abdominal muscles activity decreased with axial loads after performing fatigue task but trunk extensor activity remained constant. Results of the current study indicated that muscle recruitment strategies changed with muscle fatigue and load bearing, therefore risks of tissue injury may increase in fatigue conditions.

  8. Effect of addition of dexamethasone to ropivacaine on post-operative analgesia in ultrasonography-guided transversus abdominis plane block for inguinal hernia repair: A prospective, double-blind, randomised controlled trial.

    PubMed

    Sharma, Uma Datt; Prateek; Tak, Himani

    2018-05-01

    Ultrasonography (USG)-guided transversus abdominis plane (TAP) block is an abdominal field block with high efficacy. This study was undertaken with the aim of determining the effect of the addition of dexamethasone to 0.5% ropivacaine on post-operative analgesia in USG-guided TAP block for inguinal hernia repair. A double-blind randomised control study was conducted on sixty patients posted for inguinal hernia repair with the American Society of Anesthesiologists physical Status I or II, who were allocated two groups of 30 each. Patients in Group RS received 0.5% ropivacaine (20 ml) and normal saline (2 ml) whereas patients in Group RD received 0.5% ropivacaine (20 ml) and dexamethasone (2 ml, i.e., 8 mg), in USG-guided TAP Block on the same side, after repair of inguinal hernia under spinal anaesthesia. Visual analogue scale (VAS) scores, time for request of first analgesia and total tramadol consumption in first 24 h were compared. Unpaired Student's t -test and Mann-Whitney U-test were performed using SPSS 23 Software. Patients in Group RD had significantly lower VAS scores as compared to Group RS from 4 th to 12 th h, postoperatively. Duration of analgesia was significantly more in Group RD (547.50 [530,530] min) when compared with Group RS (387.50 [370,400] min) ( P < 0.001). The demand for intravenous tramadol was significantly low in Group RD (223.33 ± 56.83 mg) as compared to Group RS (293.33 ± 25.71 mg) ( P < 0.001). Addition of dexamethasone to ropivacaine in USG-guided TAP block significantly reduces post-operative pain and prolongs the duration of post-operative analgesia, thereby reducing analgesic consumption.

  9. Trunk Muscle Activity during Drop Jump Performance in Adolescent Athletes with Back Pain.

    PubMed

    Mueller, Steffen; Stoll, Josefine; Mueller, Juliane; Cassel, Michael; Mayer, Frank

    2017-01-01

    In the context of back pain, great emphasis has been placed on the importance of trunk stability, especially in situations requiring compensation of repetitive, intense loading induced during high-performance activities, e.g., jumping or landing. This study aims to evaluate trunk muscle activity during drop jump in adolescent athletes with back pain (BP) compared to athletes without back pain (NBP). Eleven adolescent athletes suffering back pain (BP: m/f: n = 4/7; 15.9 ± 1.3 y; 176 ± 11 cm; 68 ± 11 kg; 12.4 ± 10.5 h/we training) and 11 matched athletes without back pain (NBP: m/f: n = 4/7; 15.5 ± 1.3 y; 174 ± 7 cm; 67 ± 8 kg; 14.9 ± 9.5 h/we training) were evaluated. Subjects conducted 3 drop jumps onto a force plate (ground reaction force). Bilateral 12-lead SEMG (surface Electromyography) was applied to assess trunk muscle activity. Ground contact time [ms], maximum vertical jump force [N], jump time [ms] and the jump performance index [m/s] were calculated for drop jumps. SEMG amplitudes (RMS: root mean square [%]) for all 12 single muscles were normalized to MIVC (maximum isometric voluntary contraction) and analyzed in 4 time windows (100 ms pre- and 200 ms post-initial ground contact, 100 ms pre- and 200 ms post-landing) as outcome variables. In addition, muscles were grouped and analyzed in ventral and dorsal muscles, as well as straight and transverse trunk muscles. Drop jump ground reaction force variables did not differ between NBP and BP ( p > 0.05). Mm obliquus externus and internus abdominis presented higher SEMG amplitudes (1.3-1.9-fold) for BP ( p < 0.05). Mm rectus abdominis, erector spinae thoracic/lumbar and latissimus dorsi did not differ ( p > 0.05). The muscle group analysis over the whole jumping cycle showed statistically significantly higher SEMG amplitudes for BP in the ventral ( p = 0.031) and transverse muscles ( p = 0.020) compared to NBP. Higher activity of transverse, but not straight, trunk muscles might indicate a specific compensation strategy to support trunk stability in athletes with back pain during drop jumps. Therefore, exercises favoring the transverse trunk muscles could be recommended for back pain treatment.

  10. The importance of body mass normalisation for ultrasound measurements of the morphology of oblique abdominis muscles: the effect of age, gender, and sport practice.

    PubMed

    Linek, P

    2018-01-01

    Some studies have not considered body mass as a confounder in analysis of oblique abdominis muscles (OAM) (including the oblique externus [OE] and oblique internus [OI]), which may have led to improper interpretation of results. To assess the differences in the effect of age, gender, and physical activity between normalised for body mass and actual values of the OAM as well as to establish the effect of age, gender, and physical activity on normalised for body mass OAM thicknesses in adolescents. A real-time ultrasound was used to obtain images of the OAM. Body mass normalisation for OAM thicknesses was performed with allometric scaling and the following equations: Allometric-scaled OE = OE thickness/body mass0.88; Allometric-scaled OI = OI thickness/body mass0.72. Analysis showed that boys have significantly thicker OAM than girls, and those who practise sports have thicker OAM than non-active individuals. For allometric-scaled OAM, there was only a significant gender effect, where boys have thicker allometric-scaled OAM than girls. There was a significant correlation between participants' age and the actual value of the OAM. The correlations between age and allometric-scaled OAM were insignificant. An analysis of OAM without body mass normalisation can lead to improper interpretation of study results. Thus, future studies should analyse OE and OI thickness measurements after normalisation rather than actual values. In the adolescent population, there is no effect of age and physical activity on allometric-scaled OAM; males have thicker allometric-scaled OAM than females. (Folia Morphol 2018; 77, 1: 123-130).

  11. Ultrasound Evaluation of the Abdominal Wall and Lumbar Multifidus Muscles in Participants Who Practice Pilates: A 1-year Follow-up Case Series.

    PubMed

    Gala-Alarcón, Paula; Calvo-Lobo, César; Serrano-Imedio, Ana; Garrido-Marín, Alejandro; Martín-Casas, Patricia; Plaza-Manzano, Gustavo

    2018-04-18

    The purpose of this study was to describe ultrasound (US) changes in muscle thickness produced during automatic activation of the transversus abdominis (TrAb), internal oblique (IO), external oblique (EO), and rectus abdominis (RA), as well as the cross-sectional area (CSA) of the lumbar multifidus (LM), after 1 year of Pilates practice. A 1-year follow-up case series study with a convenience sample of 17 participants was performed. Indeed, TrAb, IO, EO, and RA thickness, as well as LM CSA changes during automatic tests were measured by US scanning before and after 1 year of Pilates practice twice per week. Furthermore, quality of life changes using the 36-Item Short Form Health Survey and US measurement comparisons of participants who practiced exercises other than Pilates were described. Statistically significant changes were observed for the RA muscle thickness reduction during the active straight leg raise test (P = .007). Participants who practiced other exercises presented a larger LM CSA and IO thickness, which was statistically significant (P < .05). Statistically significant changes were not observed for the domains of the analyzed 36-Item Short Form Health Survey (P > .05). A direct moderate correlation was observed (r = 0.562, P = .019) between the TrAb thickness before and after a 1-year follow-up. Long-term Pilates practice may reduce the RA thickness automatic activation during active straight leg raise. Furthermore, LM CSA and IO thickness increases were observed in participants who practice other exercise types in conjunction with Pilates. Despite a moderate positive correlation observed for TrAb thickness, the quality of life did not seem to be modified after long-term Pilates practice. Copyright © 2018. Published by Elsevier Inc.

  12. Long-term outcomes of patients with breast cancer after nipple-sparing mastectomy/skin-sparing mastectomy followed by immediate transverse rectus abdominis musculocutaneous flap reconstruction: Comparison with conventional mastectomy in a single center study.

    PubMed

    Lee, Sae Byul; Lee, Jong Won; Kim, Hee Jeong; Ko, Beom Seok; Son, Byung Ho; Eom, Jin Sup; Lee, Taik Jong; Ahn, Sei-Hyun

    2018-05-01

    To evaluate the oncological outcomes of patients with breast cancer after nipple-sparing mastectomy (NSM)/skin-sparing mastectomy (SSM), followed by immediate reconstruction, as compared to conventional mastectomy (CM).SSM/NSM has been increasingly used to treat women with breast cancer who wish to preserve the overlying breast skin, but concern exist regarding its oncological safety due to the potential for residual breast tissue. We report our experience performing SSM/NSM for breast cancer treatment compared to CM with a long follow-up period.All consecutive patients who underwent mastectomy for breast cancer at Asan Medical Center between January 1993 and December 2008 were identified by retrospective medical chart review. The patients who underwent NSM/SSM, followed by immediate breast reconstruction with a pedicled transverse rectus abdominis musculocutaneous flap (TRAM), were compared to the patients who underwent CM in terms of breast-cancer specific survival (BCSS) rate, distant metastasis-free survival (DMFS) rate, and local recurrence (LR) rate.During the study period, 6028 patients underwent mastectomy for breast cancer. Of these, 1032 and 4996 underwent NSM/SSM with TRAM and CM, respectively. Their median follow-up durations were 94.4 (range, 8.1-220.2) and 110.8 (range, 6.1-262.0) months, respectively. Their 5 year BCSS rates were 95.4% and 88.1%, respectively (log-rank, P < .001). Their 5 year DMFS rates were 93.0% and 85.6%, respectively (log-rank, P < .001).Relative to CM, NSM/SSM, followed by immediate breast reconstruction, may be a viable and oncologically safe surgical treatment in selected patients with breast cancer.

  13. Fat necrosis in autologous abdomen-based breast reconstruction: a systematic review.

    PubMed

    Khansa, Ibrahim; Momoh, Adeyiza O; Patel, Priti P; Nguyen, John T; Miller, Michael J; Lee, Bernard T

    2013-03-01

    Fat necrosis is a common and potentially exasperating complication of autologous breast reconstruction. The authors performed a systematic review of the English literature on autologous breast reconstruction to determine significant patient and surgical factors that are predictors of postoperative fat necrosis. A PubMed search using the terms "fat necrosis" and "breast reconstruction" was conducted. Articles were screened using predetermined inclusion and exclusion criteria. Data collected included patient characteristics, reconstructive techniques used, and the specific postoperative morbidity of interest. Patient cohorts were pooled, and the incidence of fat necrosis was calculated in the presence and absence of each risk factor. Chi-square analysis was applied, and p < 0.05 was considered statistically significant. Of 172 articles found, 70 met the inclusion criteria. The mean rate of fat necrosis was 11.3 percent. Deep inferior epigastric artery perforator flaps had the highest rate of fat necrosis (14.4 percent), followed by pedicled transverse rectus abdominis musculocutaneous (12.3 percent), superficial inferior epigastric artery (8.1 percent), and free transverse rectus abdominis musculocutaneous flaps (6.9 percent). Significant predictors of fat necrosis included obesity (p = 0.035), prereconstruction irradiation (p = 0.022), postreconstruction irradiation (p < 0.001), active smoking (p < 0.001), and abdominal scars (p = 0.05). Protective factors included supercharging (p < 0.001) and bilateral reconstruction (p = 0.01). Although there is little agreement in the literature regarding risk factors for fat necrosis, the authors were able to demonstrate several significant predictors by systematically analyzing 70 articles. Improved knowledge of the risk factors for fat necrosis can help surgeons provide improved preoperative counseling and take measures to minimize the risk of this complication.

  14. Postmastectomy reconstruction: comparative analysis of the psychosocial, functional, and cosmetic effects of transverse rectus abdominis musculocutaneous flap versus breast implant reconstruction.

    PubMed

    Cederna, P S; Yates, W R; Chang, P; Cram, A E; Ricciardelli, E J

    1995-11-01

    Over 40,000 postmastectomy breast reconstructions are performed annually. In this study, we investigated the psychosocial, functional, and cosmetic effects of transverse rectus abdominis musculocutaneous (TRAM) flap versus breast implant reconstruction. Thirty-three women who had undergone postmastectomy breast reconstruction were contacted by telephone and agreed to participate in the study. Twenty-two women completed the self-assessment questionnaires regarding their quality of life, psychological symptoms, functional status, body image, and global satisfaction. The TRAM and implant groups contained 8 and 14 patients, respectively. The groups were well matched for age, employment status, marital status, race, religion, and severity of medical and surgical illnesses. The average follow-up was 36 months. Statistical analysis of the responses revealed that women who had undergone TRAM flap reconstruction were more satisfied with how their reconstructed breast felt to the touch (p = .01), and there was a trend toward greater satisfaction with the appearance of their reconstructed breast (p = .08). However, these same patients identified more difficulties as far as functioning at work or school, performing vigorous physical activities, participating in community or religious activities, visiting with relatives, and interacting with male friends (p < .04). There were no statistically significant differences in body image or overall satisfaction. In this small cohort study, both the TRAM flap group and the implant group were satisfied with the results of their breast reconstruction, but the TRAM flap group was more satisfied with how their breast felt and tended to be more satisfied with the cosmetic result. The TRAM flap group reported greater psychological, social, and physical impairments as a result of their reconstruction.

  15. A review of randomised controlled trials comparing ultrasound-guided foam sclerotherapy with endothermal ablation for the treatment of great saphenous varicose veins.

    PubMed

    Davies, Huw Ob; Popplewell, Matthew; Darvall, Katy; Bate, Gareth; Bradbury, Andrew W

    2016-05-01

    The last 10 years have seen the introduction into everyday clinical practice of a wide range of novel non-surgical treatments for varicose veins. In July 2013, the UK National Institute for Health and Care Excellence recommended the following treatment hierarchy for varicose veins: endothermal ablation, ultrasound-guided foam sclerotherapy, surgery and compression hosiery. The aim of this paper is to review the randomised controlled trials that have compared endothermal ablation and ultrasound-guided foam sclerotherapy to determine if the level 1 evidence base still supports an "endothermal ablation first" strategy for the treatment of varicose veins. A PubMed and OVID literature search (until 31 January 2015) was performed and randomised controlled trials comparing endothermal ablation and ultrasound-guided foam sclerotherapy were obtained. Although anatomical success appeared higher with endothermal ablation than ultrasound-guided foam sclerotherapy, clinical success and patient-reported outcomes measures were similar. Morbidity and complication rates were very low and not significantly different between endothermal ablation and ultrasound-guided foam sclerotherapy. Ultrasound-guided foam sclerotherapy was consistently less expensive that endothermal ablation. All endovenous modalities appear to be successful and have a role in modern day practice. Although further work is required to optimise ultrasound-guided foam sclerotherapy technique to maximise anatomical success and minimise retreatment, the present level 1 evidence base shows there is no significant difference in clinical important outcomes between ultrasound-guided foam sclerotherapy and endothermal ablation. As ultrasound-guided foam sclerotherapy is less expensive, it is likely to be a more cost-effective option in most patients in most healthcare settings. Strict adherence to the treatment hierarchy recommended by National Institute for Health and Care Excellence seems unjustified. © The Author(s) 2015.

  16. A Spine Loading Model of Women in the Military

    DTIC Science & Technology

    1999-10-01

    Table 1.8. Left erector spinae anatomical cross-sectional areas ..................................... 42 Table 1.9. Right rectus abdominis anatomical...cross-sectional areas ................................ 43 Table 1.10. Left rectus abdominis anatomical cross-sectional areas...Right rectus abdominis coronal plane moment-arms ....................................... 59 Table 1.26. Left rectus abdominis coronal plane moment-arms

  17. Prevalence and risk factors of diastasis recti abdominis from late pregnancy to 6 months postpartum, and relationship with lumbo-pelvic pain.

    PubMed

    Fernandes da Mota, Patrícia Gonçalves; Pascoal, Augusto Gil Brites Andrade; Carita, Ana Isabel Andrade Dinis; Bø, Kari

    2015-02-01

    Diastasis recti abdominis (DRA) is an impairment characterized by a midline separation of the rectus abdominis muscles along the linea alba. It has its onset during pregnancy and the first weeks following childbirth. There is scant knowledge on both prevalence and risk factors for development of the condition. The aim of this study was to investigate the prevalence of DRA at gestational week 35 and three timepoints postpartum, possible risk factors, and the relationship between DRA and lumbo-pelvic pain. Ultrasound images of inter rectus distance (IRD) were recorded in 84 healthy primiparous women, at three locations on the linea alba. The IRD was measured at: gestational week 35 and 6-8, 12-14, and 24-26 weeks postpartum. Diagnosis of DRA was defined as 16 mm at 2 cm below the umbilicus. Independent sample t-test and binary logistic regression was used to assess differences and risk factors in women with and without DRA and women with and without lumbo-pelvic pain. P < 0.05 was considered statistically significant. The prevalence of DRA decreased from 100% at gestational week 35-39% at 6 months postpartum. No statistically significant differences were found in prepregnancy body mass index (BMI), weight gain, baby's birth weight or abdominal circumference between women with and without DRA at 6 months postpartum. Women with DRA at 6 months postpartum were not more likely to report lumbo-pelvic pain than women without DRA. DRA is prevalent at 6 months postpartum, but is not linked with lumbo-pelvic pain. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid

    MedlinePlus

    ... News Physician Resources Professions Site Index A-Z Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid ... Needle Aspiration Biopsy of the Thyroid? What is Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid? ...

  19. Ultrasound - Breast

    MedlinePlus

    ... the patient. Because ultrasound images are captured in real-time, they can show the structure and movement of ... perform an ultrasound-guided biopsy . Because ultrasound provides real-time images, it is often used to guide biopsy ...

  20. Assistive technology for ultrasound-guided central venous catheter placement.

    PubMed

    Ikhsan, Mohammad; Tan, Kok Kiong; Putra, Andi Sudjana

    2018-01-01

    This study evaluated the existing technology used to improve the safety and ease of ultrasound-guided central venous catheterization. Electronic database searches were conducted in Scopus, IEEE, Google Patents, and relevant conference databases (SPIE, MICCAI, and IEEE conferences) for related articles on assistive technology for ultrasound-guided central venous catheterization. A total of 89 articles were examined and pointed to several fields that are currently the focus of improvements to ultrasound-guided procedures. These include improving needle visualization, needle guides and localization technology, image processing algorithms to enhance and segment important features within the ultrasound image, robotic assistance using probe-mounted manipulators, and improving procedure ergonomics through in situ projections of important information. Probe-mounted robotic manipulators provide a promising avenue for assistive technology developed for freehand ultrasound-guided percutaneous procedures. However, there is currently a lack of clinical trials to validate the effectiveness of these devices.

  1. Ultrasound-guided synovial biopsy

    PubMed Central

    Sitt, Jacqueline C M; Wong, Priscilla

    2016-01-01

    Ultrasound-guided needle biopsy of synovium is an increasingly performed procedure with a high diagnostic yield. In this review, we discuss the normal synovium, as well as the indications, technique, tissue handling and clinical applications of ultrasound-guided synovial biopsy. PMID:26581578

  2. Ultrasound-guided greater occipital nerve blocks and pulsed radiofrequency ablation for diagnosis and treatment of occipital neuralgia.

    PubMed

    Vanderhoek, Matthew David; Hoang, Hieu T; Goff, Brandon

    2013-09-01

    Occipital neuralgia is a condition manifested by chronic occipital headaches and is thought to be caused by irritation or trauma to the greater occipital nerve (GON). Treatment for occipital neuralgia includes medications, nerve blocks, and pulsed radiofrequency ablation (PRFA). Landmark-guided GON blocks are the mainstay in both the diagnosis and treatment of occipital neuralgia. Ultrasound is being utilized more and more in the chronic pain clinic to guide needle advancement when performing procedures; however, there are no reports of ultrasound used to guide a diagnostic block or PRFA of the GON. We report two cases in which ultrasound was used to guide diagnostic greater occipital nerve blocks and greater occipital nerve pulsed radiofrequency ablation for treatment of occipital neuralgia. Two patients with occipital headaches are presented. In Case 1, ultrasound was used to guide diagnostic blocks of the greater occipital nerves. In Case 2, ultrasound was utilized to guide placement of radiofrequency probes for pulsed radiofrequency ablation of the greater occipital nerves. Both patients reported immediate, significant pain relief, with continued pain relief for several months. Further study is needed to examine any difference in outcomes or morbidity between the traditional landmark method versus ultrasound-guided blocks and pulsed radiofrequency ablation of the greater occipital nerves.

  3. Ultrasound-Guided Greater Occipital Nerve Blocks and Pulsed Radiofrequency Ablation for Diagnosis and Treatment of Occipital Neuralgia

    PubMed Central

    VanderHoek, Matthew David; Hoang, Hieu T; Goff, Brandon

    2013-01-01

    Occipital neuralgia is a condition manifested by chronic occipital headaches and is thought to be caused by irritation or trauma to the greater occipital nerve (GON). Treatment for occipital neuralgia includes medications, nerve blocks, and pulsed radiofrequency ablation (PRFA). Landmark-guided GON blocks are the mainstay in both the diagnosis and treatment of occipital neuralgia. Ultrasound is being utilized more and more in the chronic pain clinic to guide needle advancement when performing procedures; however, there are no reports of ultrasound used to guide a diagnostic block or PRFA of the GON. We report two cases in which ultrasound was used to guide diagnostic greater occipital nerve blocks and greater occipital nerve pulsed radiofrequency ablation for treatment of occipital neuralgia. Two patients with occipital headaches are presented. In Case 1, ultrasound was used to guide diagnostic blocks of the greater occipital nerves. In Case 2, ultrasound was utilized to guide placement of radiofrequency probes for pulsed radiofrequency ablation of the greater occipital nerves. Both patients reported immediate, significant pain relief, with continued pain relief for several months. Further study is needed to examine any difference in outcomes or morbidity between the traditional landmark method versus ultrasound-guided blocks and pulsed radiofrequency ablation of the greater occipital nerves. PMID:24282778

  4. Clinical Utility and Pitfalls of Ultrasound Guided Foreign Body Removal in War Fighters

    DTIC Science & Technology

    2015-12-01

    1 AD_________________ AWARD NUMBER: W81XWH-08-2-0162 TITLE: Clinical Utility and Pitfalls of Ultrasound Guided Foreign Body Removal in War...Clinical Utility and Pitfalls of Ultrasound Guided Foreign Body Removal in War Fighters 5a. CONTRACT NUMBER 5b. GRANT NUMBER: W81XWH-08-2-0162 5c...Purpose: To demonstrate that 1) ultrasound guided foreign body removal (USFBR) is superior to conventional surgery in the cadaver model, 2) USFBR can be

  5. Ultrasound-Guided Renal Access for Percutaneous Nephrolithotomy: A Description of Three Novel Ultrasound-Guided Needle Techniques

    PubMed Central

    Chu, Carissa; Masic, Selma; Usawachintachit, Manint; Hu, Weiguo; Yang, Wenzeng; Stoller, Marshall; Li, Jianxing

    2016-01-01

    Abstract Ultrasound-guided renal access for percutaneous nephrolithotomy (PCNL) is a safe, effective, and low-cost procedure commonly performed worldwide, but a technique underutilized by urologists in the United States. The purpose of this article is to familiarize the practicing urologist with methods for ultrasound guidance for percutaneous renal access. We discuss two alternative techniques for gaining renal access for PCNL under ultrasound guidance. We also describe a novel technique of using the puncture needle to reposition residual stone fragments to avoid additional tract dilation. With appropriate training, ultrasound-guided renal access for PCNL can lead to reduced radiation exposure, accurate renal access, and excellent stone-free success rates and clinical outcomes. PMID:26414304

  6. Ultrasound assessment of lung consolidation and reaeration after pleural effusion drainage in patients with Acute Respiratory Distress Syndrome: a pilot study.

    PubMed

    Chinardet, B; Brisson, H; Arbelot, C; Langeron, O; Rouby, J J; Lu, Q

    2016-01-01

    The aim of the pilot study was to assess by ultrasound changes in dimensions of lung consolidation and reaeration after drainage of large pleural effusion in patients with acute respiratory distress syndrome (ARDS). Lung ultrasound and blood gas were performed before, 2 hours (H2) and 24 hours (H24) after drainage of pleural effusion. Lung ultrasound aeration score was calculated. Cephalocaudal dimension and diaphragmatic transversal area of lung consolidation were measured. Ten patients were studied. Median volume of drained effusion was 675 ml at H2 and 895 at H24. Two hours after drainage, dimension of cephalocaudal consolidation and diaphragmatic transversal area decreased significantly. Lung reaeration after drainage occurred mainly in latero-inferior and postero-superior regions. PaO2/FiO2 increased significantly at H24. Ultrasound is a useful method to assess lung consolidation after pleural effusion drainage. Drainage of pleural effusion may lead to a decrease of lung consolidation and improvement of lung reaeration.

  7. Evaluation of the Normal Tonsils in Pediatric Patients With Ultrasonography.

    PubMed

    Hosokawa, Takahiro; Yamada, Yoshitake; Tanami, Yutaka; Hattori, Shinya; Sato, Yumiko; Hosokawa, Mayumi; Oguma, Eiji

    2017-05-01

    To evaluate how well the tonsils can be viewed, in addition to echogenicity, using ultrasound, and to compare these results between children younger and older than the age of 3. We evaluated the tonsils of 99 patients (72.0 ± 59.1 months) by ultrasound. Ultrasound scans of both the left and right side, in both the transverse and longitudinal planes, were obtained. Images were scored with one of four grades according to how well the tonsil border could be distinguished, 0 being the worst and 3 being the best. Grades 2 or 3 (>50% of the tonsil border was detectable) in both tonsils, in either the transverse or longitudinal image, were considered "evaluable." Echogenicity was designated as imperceptible, low echoic, or striated in appearance. Statistical analysis was performed using the Mann-Whitney U test. Bilateral tonsils were evaluable in 96.0% (96/99) of cases. The mean grades were 2.44 ± 0.65/2.03 ± 0.68 in the right transverse/longitudinal images, and 2.40 ± 0.59/2.12 ± 0.73 in the left transverse/longitudinal images. The grades in children older than the age of 3 were significantly higher than those in younger patients (all P < .05). Echogenicity classification on the right and left side revealed a striated appearance in 97.0% (96/99) and 90.0% (89/99) of cases, respectively. The tonsils of almost all pediatric patients could be evaluated by ultrasound, particularly for patients older than 3 years. Additionally, a striated pattern of the tonsils was observed in most cases. © 2017 by the American Institute of Ultrasound in Medicine.

  8. Laparoscopy in patients following transverse rectus abdominis myocutaneous flap reconstruction.

    PubMed

    Muller, C Y; Coleman, R L; Adams, W P

    2000-07-01

    We report our technique and experience performing laparoscopic pelvic surgery on four women after transverse abdominus rectus myocutaneous flap (TRAM). Examination under anesthesia is performed on all patients in the low lithotomy position parallel with the floor. The abdominal aorta is palpated and outlined. A pneumoperitoneum is created either by umbilical or left upper quadrant Veress placement. Patients with an acceptable umbilical location undergo port placement through the incision of the umbilical relocation. Other options include left upper quadrant or paramedian placement avoiding the ligamentum teres vessels. Lateral operative ports (5 mm) are placed with reference to the transverse incision present, the pelvic pathology, and the location of the umbilicus. Techniques of electrocautery, intra- and extracorporeal suturing and knot tying, and clips are preferred to minimize port size. Following unilateral or bilateral TRAM reconstruction, four consecutive breast cancer survivors underwent successful laparoscopic-assisted vaginal hysterectomy with oophorectomy using the periumbilical incision for trocar placement. The only complication was a superficial skin breakdown from an adhesive allergy that required 6 weeks for complete resolution. Laparoscopic pelvic surgery is feasible in women after TRAM reconstruction. Knowledge of anatomic and physiologic variations related to the TRAM procedure is necessary in planning a safe operation.

  9. 3D reconstruction of a carotid bifurcation from 2D transversal ultrasound images.

    PubMed

    Yeom, Eunseop; Nam, Kweon-Ho; Jin, Changzhu; Paeng, Dong-Guk; Lee, Sang-Joon

    2014-12-01

    Visualizing and analyzing the morphological structure of carotid bifurcations are important for understanding the etiology of carotid atherosclerosis, which is a major cause of stroke and transient ischemic attack. For delineation of vasculatures in the carotid artery, ultrasound examinations have been widely employed because of a noninvasive procedure without ionizing radiation. However, conventional 2D ultrasound imaging has technical limitations in observing the complicated 3D shapes and asymmetric vasodilation of bifurcations. This study aims to propose image-processing techniques for better 3D reconstruction of a carotid bifurcation in a rat by using 2D cross-sectional ultrasound images. A high-resolution ultrasound imaging system with a probe centered at 40MHz was employed to obtain 2D transversal images. The lumen boundaries in each transverse ultrasound image were detected by using three different techniques; an ellipse-fitting, a correlation mapping to visualize the decorrelation of blood flow, and the ellipse-fitting on the correlation map. When the results are compared, the third technique provides relatively good boundary extraction. The incomplete boundaries of arterial lumen caused by acoustic artifacts are somewhat resolved by adopting the correlation mapping and the distortion in the boundary detection near the bifurcation apex was largely reduced by using the ellipse-fitting technique. The 3D lumen geometry of a carotid artery was obtained by volumetric rendering of several 2D slices. For the 3D vasodilatation of the carotid bifurcation, lumen geometries at the contraction and expansion states were simultaneously depicted at various view angles. The present 3D reconstruction methods would be useful for efficient extraction and construction of the 3D lumen geometries of carotid bifurcations from 2D ultrasound images. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. [Low transverse laparotomy with rectus abdominus section in gynecology and obstetrics. Apropos of 1,000 cases].

    PubMed

    Querleu, D; Delahousse, G; Turpin, D; Leblanc, P; Debodinance, P; Boutteville, C; Meurette, J; Laurent, J C; Crépin, G

    1987-11-01

    The authors report 1,000 cases (357 cesarean sections, 230 hysterectomies for benign lesions, 157 conservative utero-adnexal procedures, 128 tubal plasties, 58 prolapse or incontinence procedures, 70 cancers) ,of laparotomies performed according to the technique described by Mouchel in 1980, i.e. strictly supra-pubic and transverse, from skin to peritoneum, including section of the rectus abdominis. This incision enables to perform in ideal technical conditions, with a minimal complication rate (3 hematomas, 2 incisional hernias for 1,000), and satisfactory esthetic results, almost all of the gynecological and obstetrical surgical procedures (90% of two among the authors' practice). The only contra-indications are, except for cases of previous median laparotomy, ovarian tumors. Neither the high risk of infection, nor obesity, extended hysterectomy, nor fetal distress, represent contra-indications, which is a definite advantage over the Pfannenstiel incision. As compared with the median incision which at some time offered similar results, the esthetics and mainly the strength of the abdominal wall are markedly superior.

  11. Ultrasound guided therapeutic injections of the cervical spine and brachial plexus.

    PubMed

    Cormick, Wes

    2014-02-01

    Introduction : Recent applications in ultrasound imaging include ultrasound assessment and ultrasound guided therapeutic injections of the spine and brachial plexus. Discussion : Ultrasound is an ideal modality for these regions as it allows accurate safe and quick injection of single or multiple sites. It has the added advantages of lack of ionising radiation, and can be done without requiring large expensive radiology equipment. Conclusion : Brachial plexus pathology may be present in patients presenting for shoulder symptoms where very little is found at imaging the shoulder. It is important to understand the anatomy and normal variants that may exist to be able to recognise when pathology is present. When pathology is demonstrated it is easy to do a trial of therapy with ultrasound guided injection of steroid around the nerve lesion. This review will outline the normal anatomy and variants and common pathology, which can be amenable to ultrasound guided injection of steroid.

  12. Cholecystectomy after breast reconstruction with a pedicled autologous tram flap. Types of surgical access

    PubMed Central

    Kostro, Justyna; Jankau, Jerzy; Bigda, Justyna; Skorek, Andrzej

    2014-01-01

    The number of breast reconstruction procedures has been increasing in recent years. One of the suggested treatment methods is breast reconstruction with a pedicled skin and muscle TRAM flap (transverse rectus abdominis muscle – TRAM). Surgical incisions performed during a cholecystectomy procedure may be located in the areas significant for flap survival. The aim of this paper is to present anatomical changes in abdominal walls secondary to pedicled skin and muscle (TRAM) flap breast reconstruction, which influence the planned access in cholecystectomy procedures. The authors present 2 cases of cholecystectomy performed due to cholelithiasis in female patients with a history of TRAM flap breast reconstruction procedures. The first patient underwent a traditional method of surgery 14 days after the reconstruction due to acute cholecystitis. The second patient underwent a laparoscopy due to cholelithiasis 7 years after the TRAM procedure. In both cases an abdominal ultrasound scan was performed prior to the operation, and surgical access was determined following consultation with a plastic surgeon. The patient who had undergone traditional cholecystectomy developed an infection of the postoperative wound. The wound was treated with antibiotics, vacuum therapy and skin grafting. After 7 weeks complete postoperative wound healing and correct healing of the TRAM flap were achieved. The patient who had undergone laparoscopy was discharged home on the second postoperative day without any complications. In order to plan a safe surgical access, it is necessary to know the changes in the anatomy of abdominal walls following a pedicled TRAM flap breast reconstruction procedure. PMID:25337177

  13. [Post-operative pain after ultrasound transversus abdominis plane block versus trocar site infiltration in laparoscopic nephrectomy: a prospective study].

    PubMed

    Araújo, Ana M; Guimarães, Joana; Nunes, Catarina S; Couto, Paula S; Amadeu, Eduarda

    Transversus abdominis plane (TAP) block is useful in reducing post-operative pain in laparoscopic nephrectomy compared to placebo. The purpose of this work is to compare post-operative pain and recovery after TAP block or trocar site infiltration (TSI) in this surgery. A prospective, single blinded study on patients scheduled for laparoscopic nephrectomy. Patients were assigned to two groups: TSI Group: trocar site infiltration at the end of surgery; TAP Group: unilateral ultrasound-guided TAP block after induction. Sevoflurane and remifentanil, in a target controlled infusion mode, were used for maintenance of general anesthesia. Before the end of surgery paracetamol, tramadol and morphine were administered. Visual analogue scale (VAS 0-100mm) at rest and with cough was applied in three moments: in recovery room (T1 at admission and T2 before discharge) and 24h after surgery (T3). Pain scores with incentive spirometer were also evaluated at T3. In recovery, morphine was administered as a rescue drug whenever VAS>30mm. Time to oral intake, chair sitting, ambulation and length of hospital stay were evaluated 24h after surgery. Student's t-test and Chi-square test, and linear regression models. A p-value<0.05 was considered significant. Data are presented as mean (SD). Forty patients were enrolled in the study. The primary outcome variable, VAS pain scores did not show a statistical significant difference between groups (p>0.05). VAS at rest (TAP vs. TSI groups) was: T1=33±29 vs. 39±32, T2=10±9 vs. 17±18 and T3=7±12 vs. 10±18. VAS with cough (TAP vs. TSI groups) was: T1=51±34 vs. 45±32, T2=24±24 vs. 33±23 and T3=20±23 vs. 23±23. VAS with incentive spirometer (TAP vs. TSI groups) was: T3=21±27 vs. 21±25. Intraoperative remifentanil consumption was similar between TAP (0.16±0.07mcg.kg -1 .min -1 ) and TSI (0.18±0.9mcg.kg -1 .min -1 ) groups. There were no differences in opioid consumption between TAP (4.4±3.49mg) and TSI (6.87±4.83mg) groups during recovery. Functional recovery parameters were not statistically different between groups. Multimodal analgesia with TAP block did not show a significant clinical benefit compared with trocar site infiltration in laparoscopic nephrectomies. Copyright © 2016 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All rights reserved.

  14. Guided Interventions for Prostate Cancer Using 3D-Transurethral Ultrasound and MRI Fusion

    DTIC Science & Technology

    2015-10-01

    AWARD NUMBER: W81XWH-14-1-0461 TITLE: Guided Interventions for Prostate Cancer Using 3D-Transurethral Ultrasound and MRI Fusion PRINCIPAL...Sep 2014 - 28 Sep 2015 4. TITLE AND SUBTITLE 5a. CONTRACT NUMBER Guided Interventions for Prostate Cancer Using 3D- Transurethral Ultrasound and...Magnetic Resonance- Ultrasound (MR-US) fusion allows for specific targeting of the tumors in real-time during clinical interventions, outside of an MR

  15. Ultrasound-guided high-intensity focused ultrasound ablation for treating uterine arteriovenous malformation.

    PubMed

    Yan, X; Zhao, C; Tian, C; Wen, S; He, X; Zhou, Y

    2017-08-01

    To explore HIFU treatment for uterine arteriovenous malformation. A case report. Gynaecological department in a university teaching hospital of China. A patient with uterine arteriovenous malformation. The diagnosis of uterine arteriovenous malformation was made through MRI. Ultrasound-guided high-intensity focused ultrasound (USgHIFU) ablation was performed. HIFU is effective in treating uterine arteriovenous malformation. The patient had reduction of the lesion volume and obvious symptom relief, without significant adverse effects. HIFU can be used as a new treatment option for uterine arteriovenous malformation. Ultrasound-guided high-intensity focused ultrasound ablation is effective in treating uterine arteriovenous malformation. © 2017 Royal College of Obstetricians and Gynaecologists.

  16. Ultrasound- versus Palpation-Guided Injection of Corticosteroid for Plantar Fasciitis: A Meta-Analysis

    PubMed Central

    Yu, Aixi; Qi, Baiwen

    2014-01-01

    Background It is controversial whether ultrasound-guided injection of corticosteroid is superior to palpation-guided injection for plantar fasciitis. This meta-analysis was performed to compare the effectiveness of ultrasound-guided and palpation-guided injection of corticosteroid for the treatment of plantar fasciitis. Methods Databases (MEDLINE, Cochrane library and EMBASE) and reference lists were searched from their establishment to August 30, 2013 for randomized controlled trials (RCTs) comparing ultrasound-guided with palpation-guided injection for plantar fasciitis. The Cochrane risk of bias (ROB) tool was used to assess the methodological quality. Outcome measurements were visual analogue scale (VAS), tenderness threshold (TT), heel tenderness index (HTI), response rate, plantar fascia thickness (PFT), hypoechogenicity and heel pad thickness (HPT). The statistical analysis was performed with software RevMan 5.2 and Stata 12.0. When I2<50%, the fixed-effects model was adopted. Otherwise the randomized-effects model was adopted. The Grading of Recommendations Assessment, Development and Evaluation (GRADE) system was used to assess the quality of evidence. Results Five RCTs with 149 patients were identified and analyzed. Compared with palpation-guided injection, ultrasound-guided injection was superior with regard to VAS, TT, response rate, PFT and hypoechogenicity. However, there was no statistical significance between the two groups for HPT and HTI. Conclusion Ultrasound-guided injection of corticosteroid tends to be more effective than palpation-guided injection. However, it needs to be confirmed by further research. PMID:24658102

  17. Applications of Doppler ultrasound in clinical vascular disease

    NASA Technical Reports Server (NTRS)

    Barnes, R. W.; Hokanson, D. E.; Sumner, D. S.; Strandness, D. E., Jr.

    1975-01-01

    Doppler ultrasound has become the most useful and versatile noninvasive technique for objective evaluation of clinical vascular disease. Commercially available continuous-wave instruments provide qualitative and quantitative assessment of venous and arterial disease. Pulsed Doppler ultrasound was developed to provide longitudinal and transverse cross-sectional images of the arterial lumen with a resolution approaching that of conventional X-ray techniques. Application of Doppler ultrasound in venous, peripheral arterial, and cerebrovascular diseases is reviewed.

  18. Ultrasound-Guided Intervention for Treatment of Trigeminal Neuralgia: An Updated Review of Anatomy and Techniques

    PubMed Central

    Allam, Abdallah El-Sayed; Khalil, Adham Aboul Fotouh; Eltawab, Basma Aly; Wu, Wei-Ting

    2018-01-01

    Orofacial myofascial pain is prevalent and most often results from entrapment of branches of the trigeminal nerves. It is challenging to inject branches of the trigeminal nerve, a large portion of which are shielded by the facial bones. Bony landmarks of the cranium serve as important guides for palpation-guided injections and can be delineated using ultrasound. Ultrasound also provides real-time images of the adjacent muscles and accompanying arteries and can be used to guide the needle to the target region. Most importantly, ultrasound guidance significantly reduces the risk of collateral injury to vital neurovascular structures. In this review, we aimed to summarize the regional anatomy and ultrasound-guided injection techniques for the trigeminal nerve and its branches, including the supraorbital, infraorbital, mental, auriculotemporal, maxillary, and mandibular nerves. PMID:29808105

  19. Anterior Cutaneous Nerve Entrapment Syndrome in a Pediatric Patient Previously Diagnosed With Functional Abdominal Pain: A Case Report.

    PubMed

    DiGiusto, Matthew; Suleman, M-Irfan

    2018-03-23

    Chronic abdominal pain is common in children and adolescents but challenging to diagnose, because practitioners may be concerned about missing serious occult disease. Abdominal wall pain is an often ignored etiology for chronic abdominal pain. Anterior cutaneous nerve entrapment syndrome causes abdominal wall pain but is frequently overlooked. Correctly diagnosing patients with anterior cutaneous nerve entrapment syndrome is important because nerve block interventions are highly successful in the remittance of pain. Here, we present the case of a pediatric patient who received a diagnosis of functional abdominal pain but experienced pain remittance after receiving a trigger-point injection and transverse abdominis plane block.

  20. Transvaginal Ultrasound-Guided Biopsy of Deep Pelvic Masses: How We Do It.

    PubMed

    Plett, Sara K; Poder, Liina; Brooks, Rebecca A; Morgan, Tara A

    2016-06-01

    The purpose of this review is to discuss the rationale and indications for transvaginal ultrasound-guided biopsy. Transvaginal ultrasound-guided biopsy can be a helpful tool for diagnosis and treatment planning in the evaluation of pelvic masses, particularly when the anatomy precludes a transabdominal or posterior transgluteal percutaneous biopsy approach. A step-by-step summary of the technique with preprocedure and postprocedure considerations is included. © 2016 by the American Institute of Ultrasound in Medicine.

  1. Cost-effectiveness of focused ultrasound, radiosurgery, and DBS for essential tremor.

    PubMed

    Ravikumar, Vinod K; Parker, Jonathon J; Hornbeck, Traci S; Santini, Veronica E; Pauly, Kim Butts; Wintermark, Max; Ghanouni, Pejman; Stein, Sherman C; Halpern, Casey H

    2017-08-01

    Essential tremor remains a very common yet medically refractory condition. A recent phase 3 study demonstrated that magnetic resonance-guided focused ultrasound thalamotomy significantly improved upper limb tremor. The objectives of this study were to assess this novel therapy's cost-effectiveness compared with existing procedural options. Literature searches of magnetic resonance-guided focused ultrasound thalamotomy, DBS, and stereotactic radiosurgery for essential tremor were performed. Pre- and postoperative tremor-related disability scores were collected from 32 studies involving 83 magnetic resonance-guided focused ultrasound thalamotomies, 615 DBSs, and 260 stereotactic radiosurgery cases. Utility, defined as quality of life and derived from percent change in functional disability, was calculated; Medicare reimbursement was employed as a proxy for societal cost. Medicare reimbursement rates are not established for magnetic resonance-guided focused ultrasound thalamotomy for essential tremor; therefore, reimbursements were estimated to be approximately equivalent to stereotactic radiosurgery to assess a cost threshold. A decision analysis model was constructed to examine the most cost-effective option for essential tremor, implementing meta-analytic techniques. Magnetic resonance-guided focused ultrasound thalamotomy resulted in significantly higher utility scores compared with DBS (P < 0.001) or stereotactic radiosurgery (P < 0.001). Projected costs of magnetic resonance-guided focused ultrasound thalamotomy were significantly less than DBS (P < 0.001), but not significantly different from radiosurgery. Magnetic resonance-guided focused ultrasound thalamotomy is cost-effective for tremor compared with DBS and stereotactic radiosurgery and more effective than both. Even if longer follow-up finds changes in effectiveness or costs, focused ultrasound thalamotomy will likely remain competitive with both alternatives. © 2017 International Parkinson and Movement Disorder Society. © 2017 International Parkinson and Movement Disorder Society.

  2. Echogenicity based approach to detect, segment and track the common carotid artery in 2D ultrasound images.

    PubMed

    Narayan, Nikhil S; Marziliano, Pina

    2015-08-01

    Automatic detection and segmentation of the common carotid artery in transverse ultrasound (US) images of the thyroid gland play a vital role in the success of US guided intervention procedures. We propose in this paper a novel method to accurately detect, segment and track the carotid in 2D and 2D+t US images of the thyroid gland using concepts based on tissue echogenicity and ultrasound image formation. We first segment the hypoechoic anatomical regions of interest using local phase and energy in the input image. We then make use of a Hessian based blob like analysis to detect the carotid within the segmented hypoechoic regions. The carotid artery is segmented by making use of least squares ellipse fit for the edge points around the detected carotid candidate. Experiments performed on a multivendor dataset of 41 images show that the proposed algorithm can segment the carotid artery with high sensitivity (99.6 ±m 0.2%) and specificity (92.9 ±m 0.1%). Further experiments on a public database containing 971 images of the carotid artery showed that the proposed algorithm can achieve a detection accuracy of 95.2% with a 2% increase in performance when compared to the state-of-the-art method.

  3. Efficacy of ultrasound-guided thoracentesis catheter drainage for pleural effusion

    PubMed Central

    Cao, Weitian; Wang, Yi; Zhou, Ningming; Xu, Bing

    2016-01-01

    The factors influencing the efficacy of ultrasound-guided thoracentesis catheter drainage were investigated in the present study. A retrospective analysis of clinical data from 435 patients who presented with a pleural effusion was performed. Patients were divided into a control group and an intervention group. Thirty-seven patients in the control group were given standard care using pleural puncture to draw the excess fluid. The 398 patients in the intervention group were treated using ultrasound-guided thoracentesis catheter drainage. The rate of successful drainage of a pleural effusion was significantly higher (P<0.05), while the rate of complication was lower, in the ultrasound-guided thoracentesis cases compared to standard care treatment. In conclusion, ultrasound-guided thoracentesis catheter drainage is an efficient, safe and minimally invasive procedure to alleviate pleural effusion. The efficacy of the procedure is related to the separation of pleural effusion, drainage tube type and tube diameter. PMID:28105155

  4. Technical tips to perform safe and effective ultrasound guided steroid joint injections in children.

    PubMed

    Parra, Dimitri A

    2015-01-01

    The aim of this article is to describe the technique used to perform ultrasound guided steroid joint injections in children in a group of joints that can be injected using ultrasound as the only image guidance modality. The technique is described and didactic figures are provided to illustrate key technical concepts. It is very important to be familiar with the sonographic appearance of the pediatric joints and the developing bone when performing ultrasound-guided joint injections in children.

  5. Robotic Assistance for Ultrasound-Guided Prostate Brachytherapy

    PubMed Central

    Fichtinger, Gabor; Fiene, Jonathan P.; Kennedy, Christopher W.; Kronreif, Gernot; Iordachita, Iulian; Song, Danny Y.; Burdette, Everette C.; Kazanzides, Peter

    2016-01-01

    We present a robotically assisted prostate brachytherapy system and test results in training phantoms and Phase-I clinical trials. The system consists of a transrectal ultrasound (TRUS) and a spatially co-registered robot, fully integrated with an FDA-approved commercial treatment planning system. The salient feature of the system is a small parallel robot affixed to the mounting posts of the template. The robot replaces the template interchangeably, using the same coordinate system. Established clinical hardware, workflow and calibration remain intact. In all phantom experiments, we recorded the first insertion attempt without adjustment. All clinically relevant locations in the prostate were reached. Non-parallel needle trajectories were achieved. The pre-insertion transverse and rotational errors (measured with a Polaris optical tracker relative to the template’s coordinate frame) were 0.25mm (STD=0.17mm) and 0.75° (STD=0.37°). In phantoms, needle tip placement errors measured in TRUS were 1.04mm (STD=0.50mm). A Phase-I clinical feasibility and safety trial has been successfully completed with the system. We encountered needle tip positioning errors of a magnitude greater than 4mm in only 2 out of 179 robotically guided needles, in contrast to manual template guidance where errors of this magnitude are much more common. Further clinical trials are necessary to determine whether the apparent benefits of the robotic assistant will lead to improvements in clinical efficacy and outcomes. PMID:18650122

  6. Intrapartum sonography for fetal head asynclitism and transverse position: sonographic signs and comparison of diagnostic performance between transvaginal and digital examination.

    PubMed

    Malvasi, Antonio; Stark, Michael; Ghi, Tullio; Farine, Dan; Guido, Marcello; Tinelli, Andrea

    2012-05-01

    The primary goal of this study was to determine the ultrasonographic signs of asynclitic and transverse head positioning. In addition, we compared the performance of intrapartum ultrasound to vaginal digital examination. 150 women were evaluated by 2D transabdominal and translabial ultrasound (US) to detect the asynclitic and deep transverse positions. Transvaginal sterile digital examinations were performed immediately after each intrapartum US assessments, the examinations were repeated at intervals of 45-90 minutes. Examiners were blinded to each other's findings (clinical or sonographic). Data were reviewed and analyzed by an independent reviewer. The efficacy of digital examination was significantly lower than US evaluation for the detection of either transverse position or asynclitism. The most frequent transverse position was the left one, while the most frequent asynclitism was the anterior one. Digital pelvic examination for detection of fetal head transverse position during labor is inferior to US, especially in the deep transverse positioning, where caput succedaneum occurs and reduces the diagnostic accuracy of vaginal digital examination. The US examination leads to early detection of persistent transverse position allowing for earlier timing and optimal technique for the operative vaginal delivery. We describe two signs for diagnosing asynclitism. The "squint sign" and the "sunset of thalamus and cerebellum signs" are two simple US signs allowing detection of anterior and posterior asynclitism.

  7. Point-of-Care Ultrasonography Findings and Care Use Among Patients Undergoing Ultrasound-Guided Shoulder Injections.

    PubMed

    Lee, Se Won; Tiu, Timothy; Roberts, Jeremy; Lee, Brian; Bartels, Matthew N; Oh-Park, Mooyeon

    2018-01-01

    The aims of the study were to assess the overall reduction of pain in patients undergoing ultrasound-guided shoulder injections and to characterize the preinjection point-of-care ultrasound findings and use of clinical services postinjection including the use of magnetic resonance imaging and surgeries. Data of 172 patients who underwent ultrasound-guided subacromial subdeltoid injection or glenohumeral joint injection were reviewed for preinjection point-of-care ultrasound findings, change in pain intensity at 2 mos from baseline, and use of care at 6 mos' postinjection. Pain intensity was measured by the numeric rating scale and a dichotomous report of global impression of significant improvement in pain. Responders were defined as those with 50% or more reduction in numeric rating scale or those with global impression of 50% or more improvement. There were 141 responders among the 172 patients analyzed. Full-thickness rotator cuff tears were higher in the ultrasound-guided subacromial subdeltoid injection group when compared with the glenohumeral joint injection group (P = 0.038) and abnormal bicipital tendon findings higher in the glenohumeral joint injection group (P = 0.016). There were no significant differences in specific abnormal U findings between responders versus nonresponders. Twelve patients had a shoulder magnetic resonance imaging and four patients underwent operative interventions after the injection. Overall pain reduction after ultrasound-guided shoulder injections was favorable in the short term. There was no specific preinjection point-of-care ultrasound findings associated with clinical pain reduction after injection. Additional imaging and operative intervention after ultrasound-guided shoulder injections seemed to be relatively low.

  8. PLUS: open-source toolkit for ultrasound-guided intervention systems.

    PubMed

    Lasso, Andras; Heffter, Tamas; Rankin, Adam; Pinter, Csaba; Ungi, Tamas; Fichtinger, Gabor

    2014-10-01

    A variety of advanced image analysis methods have been under the development for ultrasound-guided interventions. Unfortunately, the transition from an image analysis algorithm to clinical feasibility trials as part of an intervention system requires integration of many components, such as imaging and tracking devices, data processing algorithms, and visualization software. The objective of our paper is to provide a freely available open-source software platform-PLUS: Public software Library for Ultrasound-to facilitate rapid prototyping of ultrasound-guided intervention systems for translational clinical research. PLUS provides a variety of methods for interventional tool pose and ultrasound image acquisition from a wide range of tracking and imaging devices, spatial and temporal calibration, volume reconstruction, simulated image generation, and recording and live streaming of the acquired data. This paper introduces PLUS, explains its functionality and architecture, and presents typical uses and performance in ultrasound-guided intervention systems. PLUS fulfills the essential requirements for the development of ultrasound-guided intervention systems and it aspires to become a widely used translational research prototyping platform. PLUS is freely available as open source software under BSD license and can be downloaded from http://www.plustoolkit.org.

  9. Ultrasound-Guided 50% Ethyl Alcohol Injection for Patients With Malleolar and Olecranon Bursitis: A Prospective Pilot Study

    PubMed Central

    Hong, Ji Seong; Lee, Jin Hyung

    2016-01-01

    Objective To evaluate the feasibility and effect of ultrasound-guided ethyl alcohol injection on malleolar and olecranon synovial proliferative bursitis. Methods Twenty-four patients received ultrasound-guided 50% diluted ethyl alcohol injection at the site of synovial proliferative bursitis after aspiration of the free fluid. Results Swelling and symptoms significantly decreased in 13 of the 24 patients without any complications. Eleven patients had partial improvement in swelling and symptoms. Conclusion Ultrasound-guided alcohol injection could be an alternative therapeutic option before surgery in patients with chronic intractable malleolar and olecranon synovial proliferative bursitis. PMID:27152282

  10. Ultrasound-Guided Vascular Access Simulator for Medical Training: Proposal of a Simple, Economic and Effective Model.

    PubMed

    Fürst, Rafael Vilhena de Carvalho; Polimanti, Afonso César; Galego, Sidnei José; Bicudo, Maria Claudia; Montagna, Erik; Corrêa, João Antônio

    2017-03-01

    To present a simple and affordable model able to properly simulate an ultrasound-guided venous access. The simulation was made using a latex balloon tube filled with water and dye solution implanted in a thawed chicken breast with bones. The presented model allows the simulation of all implant stages of a central catheter. The obtained echogenicity is similar to that observed in human tissue, and the ultrasound identification of the tissues, balloon, needle, wire guide and catheter is feasible and reproducible. The proposed model is simple, economical, easy to manufacture and capable of realistically and effectively simulating an ultrasound-guided venous access.

  11. Comparison of the analgesic efficacy of ultrasound-guided rectus sheath block and local anesthetic infiltration for laparoscopic percutaneous extraperitoneal closure in children.

    PubMed

    Uchinami, Yuka; Sakuraya, Fumika; Tanaka, Nobuhiro; Hoshino, Koji; Mikami, Eri; Ishikawa, Taro; Fujii, Hitomi; Ishikawa, Takehiko; Morimoto, Yuji

    2017-05-01

    Ultrasound-guided rectus sheath block and local anesthetic infiltration are the standard options to improve postoperative pain for children undergoing surgery with a midline incision. However, there is no study comparing the effect of ultrasound-guided rectus sheath block with local anesthetic infiltration for children undergoing laparoscopic surgery. The aim of this trial was to compare the onset of ultrasound-guided rectus sheath block with that of local anesthetic infiltration for laparoscopic percutaneous extraperitoneal closure in children. We performed an observer-blinded, randomized, prospective trial. Enrolled patients were assigned to either an ultrasound-guided rectus sheath block group or a local anesthetic infiltration group. The ultrasound-guided rectus sheath block group (n = 17) received ultrasound-guided rectus sheath block with 0.2 ml·kg -1 of 0.375% ropivacaine per side in the posterior rectus sheath compartment. The local anesthetic infiltration group (n = 17) received local anesthetic infiltration with 0.2 ml·kg -1 of 0.75% ropivacaine. The Face, Legs, Activity, Cry, and Consolability (FLACC) pain scores were recorded at 0, 30, 60 min after arrival at the postanesthesia care unit. Of the 37 patients enrolled in this study, 34 completed the study protocol. A significant difference in the pain scale between the ultrasound-guided rectus sheath block group and local anesthetic infiltration group was found at 0 min (median: 0, interquartile range [IQR]: 0-1.5, vs median: 1, IQR 0-5, confidence interval of median [95% CI]: 0-3, P = 0.048), but no significant difference was found at 30 min (median: 1, IQR: 0-4 vs median: 6, IQR: 0-7, 95% CI: 0-5, P = 0.061), or 60 min (median: 0, IQR: 0-2 vs median: 1, IQR: 0-3, 95% CI: -1 to 1, P = 0.310). No significant difference was found in anesthesia time between the ultrasound-guided rectus sheath block and local anesthetic infiltration groups. No procedure-related complications were observed in either group. Ultrasound-guided rectus sheath block is a quicker way to control postoperative pain for pediatric patients undergoing laparoscopic extraperitoneal closure than local anesthetic infiltration, and thus may provide a clinical benefit. © 2017 John Wiley & Sons Ltd.

  12. Comparison of Oral Contrast-Enhanced Transabdominal Ultrasound Imaging With Transverse Contrast-Enhanced Computed Tomography in Preoperative Tumor Staging of Advanced Gastric Carcinoma.

    PubMed

    He, Xuemei; Sun, Jing; Huang, Xiaoling; Zeng, Chun; Ge, Yinggang; Zhang, Jun; Wu, Jingxian

    2017-12-01

    This study assessed the diagnostic performance of transabdominal oral contrast-enhanced ultrasound (US) imaging for preoperative tumor staging of advanced gastric carcinoma by comparing it with transverse contrast-enhanced computed tomography (CT). This retrospective study included 42 patients with advanced gastric cancer who underwent laparoscopy, radical surgery, or palliative surgery because of serious complications and had a body mass index of less than 25 kg/m 2 . A cereal-based oral contrast agent was used for transabdominal oral contrast-enhanced US. Retrospective analyses were conducted using preoperative tumor staging data acquired by either transabdominal oral contrast-enhanced US or transverse contrast-enhanced CT. Both contrast-enhanced US and contrast-enhanced CT examinations were reviewed by 2 experienced radiologists independently for preoperative tumor staging according to the seventh edition of the TNM classification. The accuracy, sensitivity, and specificity were calculated by comparing the results of contrast-enhanced US and contrast-enhanced CT with pathologic findings. The overall accuracies of the imaging modalities were compared by the McNemar test. No significant difference was noted in the overall accuracy of transabdominal oral contrast-enhanced US (86% [36 of 42]) and transverse contrast-enhanced CT (83% [35 of 42] P > .999). For stage T2 to T4 gastric cancer, the accuracies of transabdominal oral contrast-enhanced US were 88%, 86%, and 98%, respectively, and those of transverse contrast-enhanced CT were 93%, 83%, and 90%. The overall accuracy of transabdominal oral contrast-enhanced US was comparable with that of transverse contrast-enhanced CT for preoperative tumor staging of advanced gastric cancer. © 2017 by the American Institute of Ultrasound in Medicine.

  13. Preliminary study of ergonomic behavior during simulated ultrasound-guided regional anesthesia using a head-mounted display.

    PubMed

    Udani, Ankeet D; Harrison, T Kyle; Howard, Steven K; Kim, T Edward; Brock-Utne, John G; Gaba, David M; Mariano, Edward R

    2012-08-01

    A head-mounted display provides continuous real-time imaging within the practitioner's visual field. We evaluated the feasibility of using head-mounted display technology to improve ergonomics in ultrasound-guided regional anesthesia in a simulated environment. Two anesthesiologists performed an equal number of ultrasound-guided popliteal-sciatic nerve blocks using the head-mounted display on a porcine hindquarter, and an independent observer assessed each practitioner's ergonomics (eg, head turning, arching, eye movements, and needle manipulation) and the overall block quality based on the injectate spread around the target nerve for each procedure. Both practitioners performed their procedures without directly viewing the ultrasound monitor, and neither practitioner showed poor ergonomic behavior. Head-mounted display technology may offer potential advantages during ultrasound-guided regional anesthesia.

  14. Reflex-mediated dynamic neuromuscular stabilization in stroke patients: EMG processing and ultrasound imaging.

    PubMed

    Yoon, Hyun S; You, Joshua Sung H

    2017-07-20

    Postural core instability is associated with poor dynamic balance and a high risk of serious falls. Both neurodevelopmental treatment (NDT) and dynamic neuromuscular stabilization (DNS) core stabilization exercises have been used to improve core stability, but the outcomes of these treatments remain unclear. This study was undertaken to examine the therapeutic effects of NDT and DNS core stabilization exercises on muscular activity, core stability, and core muscle thickness. Ten participants (5 healthy adults; 5 hemiparetic stroke patients) were recruited. Surface electromyography (EMG) was used to determine core muscle activity of the transversus abdominis/internal oblique (TrA/IO), external oblique (EO), and rectus abdominis (RA) muscles. Ultrasound imaging was used to measure transversus abdominals/internal oblique (TrA/IO) thickness, and a pressure biofeedback unit (PBU) was used to measure core stability during the DNS and NDT core exercise conditions. Data are reported as median and range and were compared using nonparametric Mann - Whitney U test and Wilcoxon signed rank test at p< 0.05. Both healthy and hemiparetic stroke groups showed greater median EMG amplitude in the TrA/IO muscles, core stability, and muscle thickness values during the DNS exercise condition than during the NDT core exercise condition, respectively (p< 0.05). However, the relative changes in the EMG amplitude, core stability, and muscle thickness values were greater during the DNS exercise condition than during the NDT core exercise condition in the hemiparetic stroke patient group (p< 0.05). Our novel results provide the first clinical evidence that DNS is more effective than NDT in both healthy and hemiparetic stroke subjects to provide superior deep core muscle activation, core stabilization, and muscle thickness. Moreover, such advantageous therapeutic benefits of the DNS core stabilization exercise over the NDT exercise were more apparent in the hemiparetis stroke patients than normal controls.

  15. Supercharging the transverse rectus abdominis musculocutaneous flap: breast reconstruction for the overweight and obese population.

    PubMed

    Wu, Liza C; Iteld, Lawrence; Song, David H

    2008-06-01

    Autologous breast reconstruction with the transverse rectus abdominis musculocutaneous (TRAM) flap is traditionally based on either the superior epigastric vessels (pedicled) or the deep inferior system (free). In the overweight and obese population, both techniques have been shown to have increased complications of the reconstructed breast. Another alternative is supercharging the flap by anastamosing the deep inferior epigastric vessels to either the internal mammary or thoracodorsal systems. We present a single surgeon's experience with unilateral TRAM reconstructions supercharged to either the thoracodorsal vessels, the internal mammary system, or in one case, perforator vessels in overweight and obese patients. Nineteen consecutive overweight or obese patients underwent delayed or immediate, unilateral autologous breast reconstruction with supercharged TRAM flaps between November 2000 and November 2004. The patients ranged in age from 28 to 66 years (average 49) and had an average body mass index (BMI) of 29.5 (24.9-38.3). Twelve patients had a BMI between 25 and 29.9 kg/m2; 7 patients had BMI > or =30 kg/m2. Left-sided reconstructions were 13; right-sided reconstructions were 6. Supercharging was performed by anastamosing the deep inferior epigastric artery and vein to the thoracodorsal vessels, internal mammary vessels, or perforator vessels. Follow-up ranged from 6 to 54 months. There was a qualitative increase in blood flow measured by audible Doppler signals in all patients after the arterial and venous anastamoses. There were no cases of partial or complete flap loss. One patient had a hematoma and subsequently developed minor fat necrosis. One patient had an infection of the reconstructed breast. There were no donor site complications. Supercharging the TRAM flap by means of microvascular augmentation of the deep inferior epigastric vessels provides a safe and effective breast reconstruction in the overweight and obese population with no additional morbidity.

  16. Cost-utility analysis of great saphenous vein ablation with radiofrequency, foam and surgery in the emerging health-care setting of Thailand.

    PubMed

    Siribumrungwong, Boonying; Noorit, Pinit; Wilasrusmee, Chumpon; Leelahavarong, Pattara; Thakkinstian, Ammarin; Teerawattananon, Yot

    2016-09-01

    To conduct economic evaluations of radiofrequency ablation, ultrasound-guided foam sclerotherapy and surgery for great saphenous vein ablation. A cost-utility and cohort analysis from societal perspective was performed to estimate incremental cost-effectiveness ratio. Transitional probabilities were from meta-analysis. Direct medical, direct non-medical, indirect costs, and utility were from standard Thai costings and cohort. Probabilistic sensitivity analysis was performed to assess parameter uncertainties. Seventy-seven patients (31 radiofrequency ablation, 19 ultrasound-guided foam sclerotherapy, and 27 surgeries) were enrolled from October 2011 to February 2013. Compared with surgery, radiofrequency ablation costed 12,935 and 20,872 Baht higher, whereas ultrasound-guided foam sclerotherapy costed 6159 lower and 1558 Bath higher for outpatient and inpatient, respectively. At one year, radiofrequency ablation had slightly lower quality-adjusted life-year, whereas ultrasound-guided foam sclerotherapy yielded additional 0.025 quality-adjusted life-year gained. Because of costing lower and greater quality-adjusted life-year than other compared alternatives, outpatient ultrasound-guided foam sclerotherapy was an option being dominant. Probabilistic sensitivity analysis resulted that at the Thai ceiling threshold of 160,000 Baht/quality-adjusted life-year gained, ultrasound-guided foam sclerotherapy had chances of 0.71 to be cost-effective. Ultrasound-guided foam sclerotherapy seems to be cost-effective for treating great saphenous vein reflux compared to surgery in Thailand at one-year results. © The Author(s) 2015.

  17. Comparison of Ultrasound-Guided and Fluoroscopy-Assisted Antegrade Common Femoral Artery Puncture Techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Slattery, Michael M.; Goh, Gerard S.; Power, Sarah

    PurposeTo prospectively compare the procedural time and complication rates of ultrasound-guided and fluoroscopy-assisted antegrade common femoral artery (CFA) puncture techniques.Materials and MethodsHundred consecutive patients, undergoing a vascular procedure for which an antegrade approach was deemed necessary/desirable, were randomly assigned to undergo either ultrasound-guided or fluoroscopy-assisted CFA puncture. Time taken from administration of local anaesthetic to vascular sheath insertion in the superficial femoral artery (SFA), patients’ age, body mass index (BMI), fluoroscopy radiation dose, haemostasis method and immediate complications were recorded. Mean and median values were calculated and statistically analysed with unpaired t tests.ResultsSixty-nine male and 31 female patients underwent antegrademore » puncture (mean age 66.7 years). The mean BMI was 25.7 for the ultrasound-guided (n = 53) and 25.3 for the fluoroscopy-assisted (n = 47) groups. The mean time taken for the ultrasound-guided puncture was 7 min 46 s and for the fluoroscopy-assisted technique was 9 min 41 s (p = 0.021). Mean fluoroscopy dose area product in the fluoroscopy group was 199 cGy cm{sup 2}. Complications included two groin haematomas in the ultrasound-guided group and two retroperitoneal haematomas and one direct SFA puncture in the fluoroscopy-assisted group.ConclusionUltrasound-guided technique is faster and safer for antegrade CFA puncture when compared to the fluoroscopic-assisted technique alone.« less

  18. Endoscopic Rectus Abdominis and Prepubic Aponeurosis Repairs for Treatment of Athletic Pubalgia.

    PubMed

    Matsuda, Dean K; Matsuda, Nicole A; Head, Rachel; Tivorsak, Tanya

    2017-02-01

    Review of the English orthopaedic literature reveals no prior report of endoscopic repair of rectus abdominis tears and/or prepubic aponeurosis detachment. This technical report describes endoscopic reattachment of an avulsed prepubic aponeurosis and endoscopic repair of a vertical rectus abdominis tear immediately after endoscopic pubic symphysectomy for coexistent recalcitrant osteitis pubis as a single-stage outpatient surgery. Endoscopic rectus abdominis repair and prepubic aponeurosis repair are feasible surgeries that complement endoscopic pubic symphysectomy for patients with concurrent osteitis pubis and expand the less invasive options for patients with athletic pubalgia.

  19. The relationship of transversus abdominis and lumbar multifidus activation and prognostic factors for clinical success with a stabilization exercise program: a cross-sectional study.

    PubMed

    Hebert, Jeffrey J; Koppenhaver, Shane L; Magel, John S; Fritz, Julie M

    2010-01-01

    Hebert JJ, Koppenhaver SL, Magel JS, Fritz JM. The relationship of transversus abdominis and lumbar multifidus activation and prognostic factors for clinical success with a stabilization exercise program: a cross-sectional study. To examine the relationship between prognostic factors for clinical success with a stabilization exercise program and lumbar multifidus (LM) and transversus abdominis (TrA) muscle activation assessed using rehabilitative ultrasound imaging (RUSI). Cross-sectional study. Outpatient physical therapy clinic. Volunteers with current low back pain (N=40). Not applicable. We examined the relationship between prognostic factors associated with clinical success with a stabilization exercise program (positive prone instability test, age <40y, aberrant movements, straight leg raise >91 degrees , presence of lumbar hypermobility) and degree of TrA and LM muscle activation assessed by RUSI. Significant univariate relationships were identified between LM muscle activation and the number of prognostic factors present (Pearson correlation coefficient [r] =-.558, P=.001), as well as the individual factors of a positive prone instability test (point biserial correlation coefficient [r(pbis)]=.376, P=.018) and segmental hypermobility (r(pbis)=.358, P=.025). The multivariate analyses indicated that after controlling for other variables, the addition of the variable "number of prognostic factors present" resulted in a significant increase in R(2) (P=.006). No significant univariate or multivariate relationships were observed between the prognostic factors and TrA muscle activation. Decreased LM muscle activation, but not TrA muscle activation, is associated with the presence of factors predictive of clinical success with a stabilization exercise program. Our findings provide researchers and clinicians with evidence regarding the construct validity of the prognostic factors examined in this study, as well as the potential clinical importance of the LM muscle as a target for stabilization exercises. Copyright (c) 2010 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  20. A comparison of the effects of epidural and spinal anesthesia with ischemia-reperfusion injury on the rat transverse rectus abdominis musculocutaneous flap.

    PubMed

    Acar, Yusuf; Bozkurt, Mehmet; Firat, Ugur; Selcuk, Caferi Tayyar; Kapi, Emin; Isik, Fatma Birgul; Kuvat, Samet Vasfi; Celik, Feyzi; Bozarslan, Beri Hocaoglu

    2013-11-01

    The purpose of this study is to compare the effects of spinal and epidural anesthesia on a rat transverse rectus abdominus myocutaneous flap ischemia-reperfusion injury model.Forty Sprague-Dawley rats were divided into 4 experimental groups: group I (n = 10), sham group; group II (n = 10), control group; group III (n = 10), epidural group; and group IV (n = 10), spinal group. After the elevation of the transverse rectus abdominus myocutaneous flaps, all groups except for the sham group were subjected to normothermic no-flow ischemia for 4 hours, followed by a reperfusion period of 2 hours. At the end of the reperfusion period, biochemical and histopathological evaluations were performed on tissue samples.Although there was no significant difference concerning the malonyldialdehyde, nitric oxide, and paraoxonase levels in the spinal and epidural groups, the total antioxidant state levels were significantly increased, and the total oxidative stress levels were significantly decreased in the epidural group in comparison to the spinal group. The pathological evaluation showed that findings related to inflammation, nuclear change rates and hyalinization were significantly higher in the spinal group compared with the epidural group.Epidural anesthesia can be considered as a more suitable method that enables a decrease in ischemia-reperfusion injuries in the muscle flaps.

  1. [The effects of transversus abdominis plane block on analgesic and anesthetic consumption during total abdominal hysterectomy: a randomized controlled study].

    PubMed

    Karaman, Tugba; Ozsoy, Asker Zeki; Karaman, Serkan; Dogru, Serkan; Tapar, Hakan; Sahin, Aynur; Dogru, Hatice; Suren, Mustafa

    A transversus abdominis plane block is a peripheral block method that has been used successfully for pain relief after total abdominal hysterectomy. However, the effects of the combination of the transversus abdominis plane block and general anesthesia on analgesic and anesthetic requirements remain unclear. This randomized placebo-controlled study is aimed to evaluate the effects of transversus abdominis plane block on analgesic and anesthetic consumption during total abdominal hysterectomy under general anesthesia. Sixty-six women undergoing total abdominal hysterectomy were randomized into two groups to receive general anesthesia alone (control group) or with transversus abdominis plane block using 20mL of 0.25% bupivacaine (transversus abdominis plane group). Intraoperative remifentanil and sevoflurane consumption were recorded. We also evaluated the postoperative pain, nausea, quality of recovery scores and rescue analgesic requirement during postoperative 24hours. The total remifentanil and sevoflurane consumption is significantly lower in transversus abdominis plane group; respectively mean (SD) 0.130 (0.25) vs. 0.094 (0.02) mcg.kg -1 .min -1 ; p<0.01 and 0.295 (0.05) vs. 0.243 (0.06) mL.min -1 ; p<0.01. In the postoperative period, pain scores were significantly reduced in transversus abdominis plane group soon after surgery; median (range) 6 (2-10) vs. 3 (0-5); p<0.001, at 2h (5 [3-9] vs. 2.5 [0-6]; p<0.001), at 6h (4 [2-7] vs. 3[0-6], p<0.001), at 12h (3.5 [1-6] vs. 2 [1-5]; p=0.003). The patients in the transversus abdominis plane group had significantly higher QoR-40 scores 190.5 (175-197) vs. 176.5 (141-187); p<0.001). Combining transversus abdominis plane block with general anesthesia can provide reduced opioid and anesthetic consumption and can improve postoperative pain and quality of recovery scores in patients undergoing total abdominal hysterectomy. Copyright © 2018 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All rights reserved.

  2. Consistent evaluation of an ultrasound-guided surgical navigation system by utilizing an active validation platform

    NASA Astrophysics Data System (ADS)

    Kim, Younsu; Kim, Sungmin; Boctor, Emad M.

    2017-03-01

    An ultrasound image-guided needle tracking systems have been widely used due to their cost-effectiveness and nonionizing radiation properties. Various surgical navigation systems have been developed by utilizing state-of-the-art sensor technologies. However, ultrasound transmission beam thickness causes unfair initial evaluation conditions due to inconsistent placement of the target with respect to the ultrasound probe. This inconsistency also brings high uncertainty and results in large standard deviations for each measurement when we compare accuracy with and without the guidance. To resolve this problem, we designed a complete evaluation platform by utilizing our mid-plane detection and time of flight measurement systems. The evaluating system uses a PZT element target and an ultrasound transmitting needle. In this paper, we evaluated an optical tracker-based surgical ultrasound-guided navigation system whereby the optical tracker tracks marker frames attached on the ultrasound probe and the needle. We performed ten needle trials of guidance experiment with a mid-plane adjustment algorithm and with a B-mode segmentation method. With the midplane adjustment, the result showed a mean error of 1.62+/-0.72mm. The mean error increased to 3.58+/-2.07mm without the mid-plane adjustment. Our evaluation system can reduce the effect of the beam-thickness problem, and measure ultrasound image-guided technologies consistently with a minimal standard deviation. Using our novel evaluation system, ultrasound image-guided technologies can be compared under equal initial conditions. Therefore, the error can be evaluated more accurately, and the system provides better analysis on the error sources such as ultrasound beam thickness.

  3. Ultrasound-guided peripheral nerve blockade.

    PubMed

    Chin, Ki Jinn; Chan, Vincent

    2008-10-01

    The use of ultrasound for peripheral nerve blockade is becoming popular. Although the feasibility of ultrasound-guided nerve blockade is now clear, it is uncertain at this time whether it represents the new standard for regional anesthesia in terms of efficacy and safety. The ability to visualize nerve location, needle advancement, needle-nerve interaction, and local anesthetic spread makes ultrasound-guided nerve block an attractive option. Study results indicate that these advantages can improve the ease of block performance, block success rates, and complications. At the same time there is evidence that ultrasound-guided regional anesthesia is a unique skill in its own right, and that proficiency in it requires training and experience. Ultrasound is a valuable tool that is now available to the regional anesthesiologist, and it is fast becoming a standard part of practice. It promises to be of especial value to the less experienced practitioner. Ultrasound does not in itself, however, guarantee the efficacy and safety of peripheral nerve blockade. Proper training in its use is required and we can expect to see the development of formal standards and guidelines in this regard.

  4. Ultrasound-guided venous access for pacemakers and defibrillators.

    PubMed

    Seto, Arnold H; Jolly, Aaron; Salcedo, Jonathan

    2013-03-01

    Ultrasound guidance is widely recommended to reduce the risk of complications during central venous catheter placement. However, ultrasound guidance is not commonly utilized for implanting leads for cardiac rhythm management devices. We describe our technique of ultrasound-guided pacemaker implantation, including a novel pull-through technique that allows percutaneous guidewire insertion prior to the first incision. We review the literature and recent advances in ultrasound imaging technology that may facilitate the adoption of ultrasound guidance. Ultrasound guidance provides a safe and rapid technique for extrathoracic subclavian or axillary venous lead placement. © 2012 Wiley Periodicals, Inc.

  5. X-ray–free Ultrasound-guided Percutaneous Nephrolithotomy: How to Select the Right Patient?

    PubMed Central

    Usawachintachit, Manint; Tzou, David T.; Hu, Weiguo; Li, Jianxing; Chi, Thomas

    2017-01-01

    OBJECTIVE To identify factors associated with successful ultrasound guidance for each surgical step of ultrasound-guided percutaneous nephrolithotomy (PCNL). PATIENTS AND METHODS Consecutive patients undergoing PCNL between March 2015 and June 2016 were prospectively enrolled. An attempt was made to use ultrasound guidance in renal access, tract dilation, and nephrostomy tube placement for each patient. For steps during which ultrasound guidance was unsuccessful, fluoroscopic screening was applied. Regression analysis identified patient characteristics associated with successful use of ultrasound guidance. RESULTS A total of 96 patients composed this cohort, with a mean body mass index of 28.7 kg/m2. Mean stone size was 33.1 ± 18.9 mm, and no hydronephrosis was found in 63.5% of cases. Fluoroscopic screening was required for renal access in 27 cases (28.1%), tract dilation in 38 (39.6%), and nephrostomy tube placement in 80 (83.3%). Multivariate analysis demonstrated that successful ultrasound guidance was significantly associated with the presence of hydronephrosis for renal access and the absence of staghorn calculi for tract dilation. Ultrasound-guided nephrostomy tube placement appeared linked to surgeon experience. CONCLUSION To achieve completely x-ray–free ultrasound-guided PCNL, the ideal patient should have a hydronephrotic collecting system with no staghorn stone present. For practitioners looking to adopt ultrasound guidance into their PCNL practice, these represent the most appropriate patients to safely initiate a surgical experience. PMID:27720776

  6. Associations between low back pain, urinary incontinence, and abdominal muscle recruitment as assessed via ultrasonography in the elderly.

    PubMed

    Figueiredo, Vânia F; Amorim, Juleimar S C; Pereira, Aline M; Ferreira, Paulo H; Pereira, Leani S M

    2015-01-01

    Low back pain (LBP) and urinary incontinence (UI) are highly prevalent among elderly individuals. In young adults, changes in trunk muscle recruitment, as assessed via ultrasound imaging, may be associated with lumbar spine stability. To assess the associations between LBP, UI, and the pattern of transversus abdominis (TrA), internal (IO), and external oblique (EO) muscle recruitment in the elderly as evaluated by ultrasound imaging. Fifty-four elderly individuals (mean age: 72±5.2 years) who complained of LBP and/or UI as assessed by the McGill Pain Questionnaire, Incontinence Questionnaire-Short Form, and ultrasound imaging were included in the study. The statistical analysis comprised a multiple linear regression model, and a p-value <0.05 was considered significant. The regression models for the TrA, IO, and EO muscle thickness levels explained 2.0% (R2=0.02; F=0.47; p=0.628), 10.6% (R2=0.106; F=3.03; p=0.057), and 10.1% (R2=0.101; F=2.70; p=0.077) of the variability, respectively. None of the regression models developed for the abdominal muscles exhibited statistical significance. A significant and negative association (p=0.018; β=-0.0343) was observed only between UI and IO recruitment. These results suggest that age-related factors may have interfered with the findings of the study, thus emphasizing the need to perform ultrasound imaging-based studies to measure abdominal muscle recruitment in the elderly.

  7. Passive mechanical properties of rat abdominal wall muscles suggest an important role of the extracellular connective tissue matrix.

    PubMed

    Brown, Stephen H M; Carr, John Austin; Ward, Samuel R; Lieber, Richard L

    2012-08-01

    Abdominal wall muscles have a unique morphology suggesting a complex role in generating and transferring force to the spinal column. Studying passive mechanical properties of these muscles may provide insights into their ability to transfer force among structures. Biopsies from rectus abdominis (RA), external oblique (EO), internal oblique (IO), and transverse abdominis (TrA) were harvested from male Sprague-Dawley rats, and single muscle fibers and fiber bundles (4-8 fibers ensheathed in their connective tissue matrix) were isolated and mechanically stretched in a passive state. Slack sarcomere lengths were measured and elastic moduli were calculated from stress-strain data. Titin molecular mass was also measured from single muscle fibers. No significant differences were found among the four abdominal wall muscles in terms of slack sarcomere length or elastic modulus. Interestingly, across all four muscles, slack sarcomere lengths were quite long in individual muscle fibers (>2.4 µm), and demonstrated a significantly longer slack length in comparison to fiber bundles (p < 0.0001). Also, the extracellular connective tissue matrix provided a stiffening effect and enhanced the resistance to lengthening at long muscle lengths. Titin molecular mass was significantly less in TrA compared to each of the other three muscles (p < 0.0009), but this difference did not correspond to hypothesized differences in stiffness. Copyright © 2012 Orthopaedic Research Society.

  8. Utility of rapid on-site cytologic evaluation during endobronchial ultrasound with a guide sheath for peripheral pulmonary lesions.

    PubMed

    Izumo, Takehiro; Matsumoto, Yuji; Sasada, Shinji; Chavez, Christine; Nakai, Toshiyuki; Tsuchida, Takaaki

    2017-03-01

    The utility of rapid on-site evaluation during endobronchial ultrasound with a guide sheath for peripheral pulmonary lesions is unclear. The aim of this study was to evaluate the role of rapid on-site evaluation during endobronchial ultrasound with a guide sheath for peripheral pulmonary lesions. Consecutive patients who underwent endobronchial ultrasound with a guide sheath for the diagnosis of peripheral pulmonary lesions at our hospital between September 2012 and July 2014 were included in this retrospective study. Cytology slides were air-dried, and modified Giemsa (Diff-Quik) staining was used for rapid on-site evaluation. Additional smears were prepared for Papanicolaou staining and tissue samples were placed in formalin for histologic evaluation. The results of rapid on-site evaluation were compared with the final diagnoses of endobronchial ultrasound with a guide sheath. A total of 718 cases were included in the study population. The sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy of rapid on-site evaluation during endobronchial ultrasound with a guide sheath for peripheral pulmonary lesions was 88.6%, 65.9%, 81.2%, 77.7% and 80.1%, respectively. There were no procedure-related deaths. Rapid on-site evaluation during endobronchial ultrasound with a guide sheath had high sensitivity for peripheral pulmonary lesions. When carrying out rapid on-site evaluation of transbronchial biopsy samples from peripheral pulmonary lesions, careful interpretation and clinical correlation are necessary. © The Author 2016. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  9. Alzheimer disease in a mouse model: MR imaging-guided focused ultrasound targeted to the hippocampus opens the blood-brain barrier and improves pathologic abnormalities and behavior.

    PubMed

    Burgess, Alison; Dubey, Sonam; Yeung, Sharon; Hough, Olivia; Eterman, Naomi; Aubert, Isabelle; Hynynen, Kullervo

    2014-12-01

    To validate whether repeated magnetic resonance (MR) imaging-guided focused ultrasound treatments targeted to the hippocampus, a brain structure relevant for Alzheimer disease ( AD Alzheimer disease ), could modulate pathologic abnormalities, plasticity, and behavior in a mouse model. All animal procedures were approved by the Animal Care Committee and are in accordance with the Canadian Council on Animal Care. Seven-month-old transgenic (TgCRND8) (Tg) mice and their nontransgenic (non-Tg) littermates were entered in the study. Mice were treated weekly with MR imaging-guided focused ultrasound in the bilateral hippocampus (1.68 MHz, 10-msec bursts, 1-Hz burst repetition frequency, 120-second total duration). After 1 month, spatial memory was tested in the Y maze with the novel arm prior to sacrifice and immunohistochemical analysis. The data were compared by using unpaired t tests and analysis of variance with Tukey post hoc analysis. Untreated Tg mice spent 61% less time than untreated non-Tg mice exploring the novel arm of the Y maze because of spatial memory impairments (P < .05). Following MR imaging-guided focused ultrasound, Tg mice spent 99% more time exploring the novel arm, performing as well as their non-Tg littermates. Changes in behavior were correlated with a reduction of the number and size of amyloid plaques in the MR imaging-guided focused ultrasound-treated animals (P < .01). Further, after MR imaging-guided focused ultrasound treatment, there was a 250% increase in the number of newborn neurons in the hippocampus (P < .01). The newborn neurons had longer dendrites and more arborization after MR imaging-guided focused ultrasound, as well (P < .01). Repeated MR imaging-guided focused ultrasound treatments led to spatial memory improvement in a Tg mouse model of AD Alzheimer disease . The behavior changes may be mediated by decreased amyloid pathologic abnormalities and increased neuronal plasticity. © RSNA, 2014.

  10. Effect of surface stability on core muscle activity for dynamic resistance exercises.

    PubMed

    Willardson, Jeffrey M; Fontana, Fabio E; Bressel, Eadric

    2009-03-01

    To compare core muscle activity during resistance exercises performed on stable ground vs. the BOSU Balance Trainer. Twelve trained men performed the back squat, dead lift, overhead press, and curl lifts. The activity of the rectus abdominis, external oblique abdominis, transversus abdominis/internal oblique abdominis, and erector spinae muscles was assessed. Subjects performed each lift under three separate conditions including standing on stable ground with 50% of a 1-RM, standing on a BOSU Balance Trainer with 50% of a 1-RM, and standing on stable ground with 75% of a 1-RM. Significant differences were noted between the stable 75% of 1-RM and BOSU 50% of 1-RM conditions for the rectus abdominis during the overhead press and transversus abdominis/internal oblique abdominis during the overhead press and curl (P < .05). Conversely, there were no significant differences between the stable 75% of 1-RM and BOSU 50% of 1-RM conditions for the external obliques and erector spinae across all lifts examined. Furthermore, there were no significant differences between the BOSU 50% of 1-RM and stable 50% of 1-RM conditions across all muscles and lifts examined. The current study did not demonstrate any advantage in utilizing the BOSU Balance Trainer. Therefore, fitness trainers should be advised that each of the aforementioned lifts can be performed while standing on stable ground without losing the potential core muscle training benefits.

  11. Noninvasive Label-Free Detection of Micrometastases in the Lymphatics with Ultrasound-Guided Photoacoustic Imaging

    DTIC Science & Technology

    2015-10-01

    imaging can be used to guide dissection. We have also successfully integrated a programmable ultrasound machine (Verasonics Vantage ) and tunable pulsed...Mobile HE) with the programmable ultrasound machine (Verasonics Vantage ). We have synchronized the signals to enable interleaved acquisition of US

  12. Ultrasound in regional anaesthesia.

    PubMed

    Griffin, J; Nicholls, B

    2010-04-01

    Ultrasound guidance is rapidly becoming the gold standard for regional anaesthesia. There is an ever growing weight of evidence, matched with improving technology, to show that the use of ultrasound has significant benefits over conventional techniques, such as nerve stimulation and loss of resistance. The improved safety and efficacy that ultrasound brings to regional anaesthesia will help promote its use and realise the benefits that regional anaesthesia has over general anaesthesia, such as decreased morbidity and mortality, superior postoperative analgesia, cost-effectiveness, decreased postoperative complications and an improved postoperative course. In this review we consider the evidence behind the improved safety and efficacy of ultrasound-guided regional anaesthesia, before discussing its use in pain medicine, paediatrics and in the facilitation of neuraxial blockade. The Achilles' heel of ultrasound-guided regional anaesthesia is that anaesthetists are far more familiar with providing general anaesthesia, which in most cases requires skills that are achieved faster and more reliably. To this ends we go on to provide practical advice on ultrasound-guided techniques and the introduction of ultrasound into a department.

  13. Intraoperative Ultrasound for Peripheral Nerve Applications.

    PubMed

    Willsey, Matthew; Wilson, Thomas J; Henning, Phillip Troy; Yang, Lynda J-S

    2017-10-01

    Offering real-time, high-resolution images via intraoperative ultrasound is advantageous for a variety of peripheral nerve applications. To highlight the advantages of ultrasound, its extraoperative uses are reviewed. The current intraoperative uses, including nerve localization, real-time evaluation of peripheral nerve tumors, and implantation of leads for peripheral nerve stimulation, are reviewed. Although intraoperative peripheral nerve localization has been performed previously using guide wires and surgical dyes, the authors' approach using ultrasound-guided instrument clamps helps guide surgical dissection to the target nerve, which could lead to more timely operations and shorter incisions. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Combined magnetic resonance imaging and ultrasound echography guidance for motion compensated HIFU interventions

    NASA Astrophysics Data System (ADS)

    Ries, Mario; de Senneville, Baudouin Denis; Regard, Yvan; Moonen, Chrit

    2012-11-01

    The objective of this study is to evaluate the feasibility to integrate ultrasound echography as an additional imaging modality for continuous target tracking, while performing simultaneously real-time MR- thermometry to guide a High Intensity Focused Ultrasound (HIFU) ablation. Experiments on a moving phantom were performed with MRI-guided HIFU during continuous ultrasound echography. Real-time US echography-based target tracking during MR-guided HIFU heating was performed with heated area dimensions similar to those obtained for a static target. The combination of both imaging modalities shows great potential for real-time beam steering and MR-thermometry.

  15. Accuracy of ultrasound-guided nerve blocks of the cervical zygapophysial joints.

    PubMed

    Siegenthaler, Andreas; Mlekusch, Sabine; Trelle, Sven; Schliessbach, Juerg; Curatolo, Michele; Eichenberger, Urs

    2012-08-01

    Cervical zygapophysial joint nerve blocks typically are performed with fluoroscopic needle guidance. Descriptions of ultrasound-guided block of these nerves are available, but only one small study compared ultrasound with fluoroscopy, and only for the third occipital nerve. To evaluate the potential usefulness of ultrasound-guidance in clinical practice, studies that determine the accuracy of this technique using a validated control are essential. The aim of this study was to determine the accuracy of ultrasound-guided nerve blocks of the cervical zygapophysial joints using fluoroscopy as control. Sixty volunteers were studied. Ultrasound-imaging was used to place the needle to the bony target of cervical zygapophysial joint nerve blocks. The levels of needle placement were determined randomly (three levels per volunteer). After ultrasound-guided needle placement and application of 0.2 ml contrast dye, fluoroscopic imaging was performed for later evaluation by a blinded pain physician and considered as gold standard. Raw agreement, chance-corrected agreement κ, and chance-independent agreement Φ between the ultrasound-guided placement and the assessment using fluoroscopy were calculated to quantify accuracy. One hundred eighty needles were placed in 60 volunteers. Raw agreement was 87% (95% CI 81-91%), κ was 0.74 (0.64-0.83), and Φ 0.99 (0.99-0.99). Accuracy varied significantly between the different cervical nerves: it was low for the C7 medial branch, whereas all other levels showed very good accuracy. Ultrasound-imaging is an accurate technique for performing cervical zygapophysial joint nerve blocks in volunteers, except for the medial branch blocks of C7.

  16. Focused Ultrasound Surgery for Uterine Fibroids

    MedlinePlus

    ... ultrasound surgery, your doctor may perform a pelvic magnetic resonance imaging (MRI) scan before treatment. Focused ultrasound surgery — also called magnetic resonance-guided focused ultrasound surgery or focused ultrasound ...

  17. Comparison between ultrasound guided technique and digital palpation technique for radial artery cannulation in adult patients: An updated meta-analysis of randomized controlled trials.

    PubMed

    Bhattacharjee, Sulagna; Maitra, Souvik; Baidya, Dalim K

    2018-06-01

    Possible advantages and risks associated with ultrasound guided radial artery cannulation in-comparison to digital palpation guided method in adult patients are not fully known. We have compared ultrasound guided radial artery cannulation with digital palpation technique in this meta-analysis. Meta-analysis of randomized controlled trials. Trials conducted in operating room, emergency department, cardiac catheterization laboratory. PubMed and Cochrane Central Register of Controlled Trials (CENTRAL) were searched (from 1946 to 20th November 2017) to identify prospective randomized controlled trials in adult patients. Two-dimensional ultrasound guided radial artery catheterization versus digital palpation guided radial artery cannulation. Overall cannulation success rate, first attempt success rate, time to cannulation and mean number of attempts to successful cannulation. Odds ratio (OR) and standardized mean difference (SMD) or mean difference (MD) with 95% confidence interval (CI) were calculated for categorical and continuous variables respectively. Data of 1895 patients from 10 studies have been included in this meta- analysis. Overall cannulation success rate was similar between ultrasound guided technique and digital palpation [OR (95% CI) 2.01 (1.00, 4.06); p = 0.05]. Ultrasound guided radial artery cannulation is associated with higher first attempt success rate of radial artery cannulation in comparison to digital palpation [OR (95% CI) 2.76 (186, 4.10); p < 0.001]. No difference was seen in time to cannulate [SMD (95% CI) -0.31 (-0.65, 0.04); p = 0.30] and mean number of attempt [MD (95% CI) -0.65 (-1.32, 0.02); p = 0.06] between USG guided technique with palpation technique. Radial artery cannulation by ultrasound guidance may increase the first attempt success rate but not the overall cannulation success when compared to digital palpation technique. However, results of this meta-analysis should be interpreted with caution due presence of heterogeneity. Copyright © 2018 Elsevier Inc. All rights reserved.

  18. Enhanced Lesion Visualization in Image-Guided Noninvasive Surgery With Ultrasound Phased Arrays

    DTIC Science & Technology

    2001-10-25

    81, 1995. [4] N. Sanghvi et al., “Noninvasive surgery of prostate tissue by high-intensity focused ultrasound ,” IEEE Trans. UFFC, vol. 43, no. 6, pp...ENHANCED LESION VISUALIZATION IN IMAGE-GUIDED NONINVASIVE SURGERY WITH ULTRASOUND PHASED ARRAYS Hui Yao, Pornchai Phukpattaranont and Emad S. Ebbini...Department of Electrical and Computer Engineering University of Minnesota Minneapolis, MN 55455 Abstract- We describe dual-mode ultrasound phased

  19. Complications and adequacy of transplant kidney biopsies: A comparison of techniques.

    PubMed

    Plattner, Brett W; Chen, Pauline; Cross, Richard; Leavitt, Matthew A; Killen, Paul D; Heung, Michael

    2018-05-01

    Kidney biopsies are an essential tool in the diagnosis and management of kidney diseases, particularly in kidney transplant recipients. Biopsies carry a risk for serious complications and not all biopsies achieve adequate tissue. We examined the impact of kidney biopsy technique on complications and biopsy adequacy. The cohort consisted of consecutive kidney transplant patients undergoing biopsy by one of three techniques: ultrasound localization, real-time ultrasound guidance, and ultrasound-guided trocar placement. Variables of interest included patient characteristics and procedural characteristics. The primary outcome was serious complication attributable to kidney biopsy, and the secondary outcome was biopsy adequacy as defined by Banff criteria. Among 263 patients undergoing biopsy, 27 (10.3%) had a complication (14 with gross hematuria, 10 requiring blood transfusion, 3 requiring an unplanned interventional radiology procedure, 1 kidney loss; no deaths). Complications were more common among patients biopsied using ultrasound-guided trocar compared to real-time ultrasound and ultrasound localization (21.4% vs 7.9% vs 7.1%, respectively, p = 0.008). After adjusting for patient and procedure characteristics, technique was no longer significantly associated with complication. Biopsy adequacy was significantly higher when using ultrasound localization and real-time ultrasound compared to ultrasound-guided trocar (84.6% vs 86.8% vs 69.6%, p = 0.029), and this finding persisted in adjusted analysis. Kidney biopsy complications appear to be similar when using any of the three techniques examined in our study. However, ultrasound-guided trocar technique may yield lower biopsy adequacy when compared to non-trocar techniques.

  20. Towards enabling ultrasound guidance in cervical cancer high-dose-rate brachytherapy

    NASA Astrophysics Data System (ADS)

    Wong, Adrian; Sojoudia, Samira; Gaudet, Marc; Yap, Wan Wan; Chang, Silvia D.; Abolmaesumi, Purang; Aquino-Parsons, Christina; Moradi, Mehdi

    2014-03-01

    MRI and Computed Tomography (CT) are used in image-based solutions for guiding High Dose Rate (HDR) brachytherapy treatment of cervical cancer. MRI is costly and CT exposes the patients to ionizing radiation. Ultrasound, on the other hand, is affordable and safe. The long-term goal of our work is to enable the use of multiparametric ultrasound imaging in image-guided HDR for cervical cancer. In this paper, we report the development of enabling technology for ultrasound guidance and tissue typing. We report a system to obtain the 3D freehand transabdominal ultrasound RF signals and B-mode images of the uterus, and a method for registration of ultrasound to MRI. MRI and 3D ultrasound images of the female pelvis were registered by contouring the uterus in the two modalities, creating a surface model, followed by rigid and B-spline deformable registration. The resulting transformation was used to map the location of the tumor from the T2-weighted MRI to ultrasound images and to determine cancerous and normal areas in ultrasound. B-mode images show a contrast for cancer vs. normal tissue. Our study shows the potential and the challenges of ultrasound imaging in guiding cervical cancer treatments.

  1. Body Mass Normalization for Ultrasound Measurements of Adolescent Lateral Abdominal Muscle Thickness.

    PubMed

    Linek, Pawel; Saulicz, Edward; Wolny, Tomasz; Myśliwiec, Andrzej

    2017-04-01

    The purpose of this study was to determine the value of the allometric parameter for ultrasound measurements of the thickness of the oblique external (OE), internal (OI), and transversus abdominis (TrA) muscles in the adolescent population. The allometric parameter is the slope of the linear regression line between the log transformed body mass and log transformed muscle size measurement. The study included 321 adolescents between the ages of 10 and 17, consisting of 160 boys and 161 girls. The participants were recruited from local schools and attended regular school classes at normal grade levels. All individuals with no signs of scoliosis (screening with use of a scoliometer), and no surgical procedures performed on the trunk area were included. A real-time ultrasound B-scanner with a linear array transducer was used to obtain images of the lateral abdominal muscles from both sides of the body. The correlation between body mass and the OE muscle was r = 0.69; the OI muscle r = 0.68; and the TrA muscle r = 0.53 (in all cases, P < .0001). The allometric parameter for the OE was 0.88296; the OI 0.718756; and the TrA 0.60986. Using these parameters, no significant correlations were found between body mass and the allometric-scaled thickness of the lateral abdominal muscles. Significant positive correlations exist between body mass and lateral abdominal muscle thickness assessed by ultrasound imaging. Therefore, it is reasonable to advise that the values of the allometric parameters for OE, OI, and TrA obtained in this study should be used in other studies performed on adolescents. © 2016 by the American Institute of Ultrasound in Medicine.

  2. Gestrinone combined with ultrasound-guided aspiration and ethanol injection for treatment of chocolate cyst of ovary.

    PubMed

    Wu, Xiaoyun; Xu, Yun

    2015-05-01

    The aim of this study was to determine clinical performance of gestrinone combined with ultrasound-guided aspiration and ethanol injection in treating chocolate cyst of ovary. Sixty-eight patients enrolled in this study were randomly divided into two groups: control group and combination treatment group. In the control group, 34 patients were treated with ultrasound-guided aspiration and ethanol injection. In the combination treatment group, 34 patients received gestrinone p.o. following ultrasound-guided aspiration and ethanol injection. The recurrence rate of chocolate cyst was 10-fold lower in the combination treatment group (2.94%, 1/34) than in the control group (29.4%, 10/34) at 12 months. The effective rate for reduction of chocolate cyst was significantly higher in the combination treatment group (94.12%, 32/34) than in the control group (64.71%, 22/34) (P = 0.009). Gestrinone combined with ultrasound-guided aspiration and ethanol injection therapy is an effective treatment for ovarian chocolate cyst with low recurrence rate. © 2014 The Authors. Journal of Obstetrics and Gynaecology Research © 2014 Japan Society of Obstetrics and Gynecology.

  3. Reliability tests and guidelines for B-mode ultrasound assessment of central adiposity.

    PubMed

    Stoner, Lee; Chinn, Victoria; Cornwall, Jon; Meikle, Grant; Page, Rachel; Lambrick, Danielle; Faulkner, James

    2015-11-01

    Ultrasound represents a validated and relatively inexpensive diagnostic device for assessing central adiposity; however, widespread adoption has been impeded by the lack of reliable standard operating procedures. To examine the reliability of, and describe guidelines for, ultrasound-derived recording of intra-abdominal fat thickness (IAT) and maximal preperitoneal fat thickness (PFT). Ultrasound scans were obtained from 20 adults (50% female, 26 ± 7 years, 24·5 kg/m(2) ) on three different mornings. IAT was assessed 2 cm above the umbilicus (transverse plane) measuring from linea alba to: (i) anterior aorta, (ii) posterior aorta and (iii) anterior aspect of the vertebral column. PFT was measured from linea alba to visceral peritoneum in (i) sagittal and (ii) transverse planes, immediately over and inferior to the xiphi-sternum, respectively. For IAT, the criterion intraclass correlation coefficient (ICC) of 0·75 was exceeded for measurements to anterior aorta (0·95), posterior aorta (0·94) and vertebra (0·96). The reliability coefficient expressed as a percentage of the mean (RC%) was lowest (better) for measurement to vertebrae (9·8%). For PFT, mean thickness was comparable for sagittal (1·74 cm) and transverse (1·76 cm) planes; ICC values were also comparable for both planes (0·98 vs. 0·98, respectively), as were RC% (7·5% vs. 7·1%, respectively). IAT assessments to the vertebra were marginally more reliable than those to other structures. While PFT assessments were equally reliable for both measurements planes, precise probe placement was easier for the sagittal plane. Based on these findings, guidelines for the reliable measurement of central adiposity using ultrasound are presented. © 2015 Stichting European Society for Clinical Investigation Journal Foundation.

  4. Guiding intramuscular diaphragm injections using real-time ultrasound and electromyography.

    PubMed

    Sarwal, Aarti; Cartwright, Michael S; Mitchell, Erin; Williams, Koudy; Walker, Francis O; Childers, Martin K

    2015-02-01

    We describe a unique method that combines ultrasound and electromyography to guide intramuscular diaphragm injections in anesthetized large animals. Ultrasound was used to visualize the diaphragm on each side of spontaneously breathing, anesthetized beagle dogs and cynomolgus macaques. An electromyography (EMG) needle was introduced and directed by ultrasound to confirm that the needle entered the muscular portion of the diaphragm, and methylene blue was injected. Injection accuracy was confirmed upon necropsy by tracking the spread of methylene blue. All methylene blue injections were confirmed to have been placed appropriately into the diaphragm. This study demonstrates the feasibility and accuracy of using ultrasound and EMG to guide injections and to reduce complications associated with conventional blind techniques. Ultrasound guidance can be used for clinical EMG of the diaphragm. Future applications may include targeted diaphragm injections with gene replacement therapy in neuromuscular diseases. © 2014 Wiley Periodicals, Inc.

  5. Guiding Intramuscular Diaphragm Injections Using Real-time Ultrasound & Electromyography

    PubMed Central

    Sarwal, Aarti; Cartwright, Michael S.; Mitchell, Erin; Williams, Koudy; Walker, Francis O.; Childers, Martin K.

    2014-01-01

    Introduction We describe a unique method that combines ultrasound and electromyography to guide intramuscular diaphragm injections in anesthetized large animals. Methods Ultrasound was used to visualize the diaphragm on each side of spontaneously breathing, anesthetized beagle dogs and cynomolgus macaques. An electromyography needle was introduced and directed by ultrasound to confirm that the needle entered the muscular portion of the diaphragm, and methylene blue was injected. Injection accuracy was confirmed upon necropsy by tracking the spread of methylene blue. Results All methylene blue injections were confirmed to have been placed appropriately into the diaphragm. Conclusions This study demonstrates the feasibility and accuracy of using ultrasound and EMG to guide injections and to reduce complications associated with conventional blind techniques. Ultrasound guidance can be used for clinical electromyography of the diaphragm. Future applications may include targeted diaphragm injections with gene replacement therapy in neuromuscular diseases. PMID:25354257

  6. Remotely Guided Breast Sonography for Long-Term Space Missions: A Case Report and Discussion.

    PubMed

    Silva-Martinez, Jackelynne P; Sorice Genaro, Andreia; Wen, Hui Annie; Glauber, Naama; Russomano, Thais

    2017-12-01

    Space radiation can cause different types of cancers in crewmembers, especially during long-term space missions. To date, a complete bilateral breast ultrasound has not been performed at the International Space Station (ISS). A breast screening imaging technique could be a useful tool for early identification of breast cancer in astronauts. We hypothesized that breast ultrasound performed by a crewmember while being remotely guided by a specialist from the ground could be an essential tool for medical diagnosis in space. This project aimed to test an ultrasound screening protocol for breast tissue using real-time remotely guided telemedicine techniques. One female volunteer, with no previous medical experience, performed a self-scanned bilateral breast ultrasound exam guided by a remote sonographer. Dynamic ultrasound images were collected using a 25 mm broadband linear array transducer. To simulate fluid shift on the volunteer during microgravity, the bed was tilted -6°. Recorded ultrasound images were analyzed by radiologists, comparing the findings with a gold standard. The experiment demonstrated that real-time remotely guided sonography exam is feasible and can yield meaningful clinical results. This case study showed that remotely guided breast ultrasound can be performed and might become an important tool for diagnosis of breast cancer in space missions. The results cannot be generalized based on one subject, and additional research is warranted in this area in addition to its validation on the ISS. This technique, however, has potential for use as part of preventive medicine procedures for long-term space missions at the ISS, and eventually for human settlements on the Moon and Mars.

  7. Novel ultrasound-responsive chitosan/perfluorohexane nanodroplets for image-guided smart delivery of an anticancer agent: Curcumin.

    PubMed

    Baghbani, Fatemeh; Chegeni, Mahdieh; Moztarzadeh, Fathollah; Hadian-Ghazvini, Samaneh; Raz, Majid

    2017-05-01

    Ultrasound-responsive nanodroplets are a class of new emerging smart drug delivery systems which provide image-guided nano-therapy of various diseases, especially cancers. Here, we developed multifunctional smart curcumin-loaded chitosan/perfluorohexane nanodroplets for contrast-ultrasound imaging and on-demand drug delivery. The nanodroplets were synthesized via nanoemulsion process. The optimal formulation with the size of 101.2nm and 77.8% curcumin entrapment was chosen for release study and cytotoxicity evaluation. Sonication at the frequency of 1MHz, 2W/cm 2 for 4min triggered the release of 63.5% of curcumin from optimal formulation (Cur-NDs-2). Ultrasound aided release study indicated that the concentration of perfluorohexane and the degree of acoustic droplet vaporization play important role in ultrasound-active drug release. B-mode ultrasound imaging confirmed strong ultrasound contrast of chitosan nanodroplets even at low concentrations via droplet to bubble transition. Finally, cytotoxicity of the ultrasound-responsive nanodroplets in the presence of ultrasound was evaluated in-vitro on 4T1 human breast cancer cells. Cell growth inhibitory effects of curcumin-loaded nanodroplets significantly increased by ultrasound exposure. According to the obtained results, these ultrasound responsive curcumin-loaded chitosan/perfluorohexane nanodroplets have a great potential for imaged-guided cancer therapy. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Cost-Effectiveness Comparison of Imaging-Guided Prostate Biopsy Techniques: Systematic Transrectal Ultrasound, Direct In-Bore MRI, and Image Fusion.

    PubMed

    Venderink, Wulphert; Govers, Tim M; de Rooij, Maarten; Fütterer, Jurgen J; Sedelaar, J P Michiel

    2017-05-01

    Three commonly used prostate biopsy approaches are systematic transrectal ultrasound guided, direct in-bore MRI guided, and image fusion guided. The aim of this study was to calculate which strategy is most cost-effective. A decision tree and Markov model were developed to compare cost-effectiveness. Literature review and expert opinion were used as input. A strategy was deemed cost-effective if the costs of gaining one quality-adjusted life year (incremental cost-effectiveness ratio) did not exceed the willingness-to-pay threshold of €80,000 (≈$85,000 in January 2017). A base case analysis was performed to compare systematic transrectal ultrasound- and image fusion-guided biopsies. Because of a lack of appropriate literature regarding the accuracy of direct in-bore MRI-guided biopsy, a threshold analysis was performed. The incremental cost-effectiveness ratio for fusion-guided biopsy compared with systematic transrectal ultrasound-guided biopsy was €1386 ($1470) per quality-adjusted life year gained, which was below the willingness-to-pay threshold and thus assumed cost-effective. If MRI findings are normal in a patient with clinically significant prostate cancer, the sensitivity of direct in-bore MRI-guided biopsy has to be at least 88.8%. If that is the case, the incremental cost-effectiveness ratio is €80,000 per quality-adjusted life year gained and thus cost-effective. Fusion-guided biopsy seems to be cost-effective compared with systematic transrectal ultrasound-guided biopsy. Future research is needed to determine whether direct in-bore MRI-guided biopsy is the best pathway; in this study a threshold was calculated at which it would be cost-effective.

  9. Visualization of scoliotic spine using ultrasound-accessible skeletal landmarks

    NASA Astrophysics Data System (ADS)

    Church, Ben; Lasso, Andras; Schlenger, Christopher; Borschneck, Daniel P.; Mousavi, Parvin; Fichtinger, Gabor; Ungi, Tamas

    2017-03-01

    PURPOSE: Ultrasound imaging is an attractive alternative to X-ray for scoliosis diagnosis and monitoring due to its safety and inexpensiveness. The transverse processes as skeletal landmarks are accessible by means of ultrasound and are sufficient for quantifying scoliosis, but do not provide an informative visualization of the spine. METHODS: We created a method for visualization of the scoliotic spine using a 3D transform field, resulting from thin-spline interpolation of a landmark-based registration between the transverse processes that we localized in both the patient's ultrasound and an average healthy spine model. Additional anchor points were computationally generated to control the thin-spline interpolation, in order to gain a transform field that accurately represents the deformation of the patient's spine. The transform field is applied to the average spine model, resulting in a 3D surface model depicting the patient's spine. We applied ground truth CT from pediatric scoliosis patients in which we reconstructed the bone surface and localized the transverse processes. We warped the average spine model and analyzed the match between the patient's bone surface and the warped spine. RESULTS: Visual inspection revealed accurate rendering of the scoliotic spine. Notable misalignments occurred mainly in the anterior-posterior direction, and at the first and last vertebrae, which is immaterial for scoliosis quantification. The average Hausdorff distance computed for 4 patients was 2.6 mm. CONCLUSIONS: We achieved qualitatively accurate and intuitive visualization to depict the 3D deformation of the patient's spine when compared to ground truth CT.

  10. Musculoskeletal ultrasound: how to treat calcific tendinitis of the rotator cuff by ultrasound-guided single-needle lavage technique.

    PubMed

    Lee, Kenneth S; Rosas, Humberto G

    2010-09-01

    The purpose of this video article is to illustrate the ultrasound appearance of calcium deposition in the rotator cuff and provide a detailed step-by-step protocol for performing the ultrasound-guided single-needle lavage technique for the treatment of calcific tendinitis with emphasis on patient positioning, necessary supplies, real-time lavage technique, and steroid injection into the subacromial subdeltoid bursa. Musculoskeletal ultrasound is well established as a safe, cost-effective imaging tool in diagnosing and treating common musculoskeletal disorders. Calcific tendinitis of the rotator cuff is a common disabling cause of shoulder pain. Although most cases are self-limiting, a subset of patients is refractory to conservative therapy and requires treatment intervention. Ultrasound-guided lavage is an effective and safe minimally-invasive treatment not readily offered in the United States as an alternative to surgery, perhaps because of the limited prevalence of musculoskeletal ultrasound programs and limited training. On completion of this video article, the participant should be able to develop an appropriate diagnostic and therapeutic algorithm for the treatment of calcific tendinitis of the rotator cuff using ultrasound.

  11. Transcranial MR-Guided Focused Ultrasound: A Review of the Technology and Neuro Applications

    PubMed Central

    Ghanouni, Pejman; Pauly, Kim Butts; Elias, W. Jeff; Henderson, Jaimie; Sheehan, Jason; Monteith, Stephen; Wintermark, Max

    2015-01-01

    MR guided focused ultrasound is a new, minimally invasive method of targeted tissue thermal ablation that may be of use to treat central neuropathic pain, essential tremor, Parkinson tremor, and brain tumors. The system has also been used to temporarily disrupt the blood-brain barrier to allow targeted drug delivery to brain tumors. This article reviews the physical principles of MR guided focused ultrasound and discusses current and potential applications of this exciting technology. PMID:26102394

  12. Acute abdominal rhabdomyolysis after body building exercise: is there a "rectus abdominus syndrome?".

    PubMed

    Schmitt, H P; Bersch, W; Feustel, H P

    1983-01-01

    Report of a 19-year-old man who was admitted to the hospital after vigorous exercise with signs of the "acute abdomen" syndrome. Since intestinal reasons for the complaints were excluded, a myocardial infarction was considered. However, the excessively increased serum CK levels indicated a disorder of the voluntary muscles. A biopsy taken from the rectus abdominis revealed typical features of acute rhabdomyolysis, which was obviously restricted to the rectus abdominis. Together with a somewhat later observed autopsy case of a young male with acute abdominal rhabdomyolysis, also restricted to the rectus abdominis, this case gives rise to discuss, whether there exists a "rectus abdominis syndrome" analogous to the anterior tibial syndrome.

  13. Evaluation of knee cartilage thickness: A comparison between ultrasound and magnetic resonance imaging methods.

    PubMed

    Schmitz, Randy J; Wang, Hsin-Min; Polprasert, Daniel R; Kraft, Robert A; Pietrosimone, Brian G

    2017-03-01

    Establishing clinically accessible measures of cartilage health is critical for assessing effectiveness of protocols to reduce risk of osteoarthritis (OA) development and progression. Cartilage thickness is one important measure in describing both OA development and progression. The objective was to determine the relationship between ultrasound and MRI measures of cartilage thickness in the medial femoral condyle. Mean cartilage thicknesses of the left medial femoral cartilage were measured via T1 weighted MRI and ultrasound imaging from transverse, anterior, middle, and posterior medial femoral regions in 10 healthy females (Mean±Std Dev) (1.66±0.08m, 59.5±8.3kg, 21.6±1.4years) and nine healthy males (1.80±0.08m, 79.1±6.2kg, 21.7±1.5years). Pearson correlations examined relationships between MRI and ultrasound measures. Bland-Altman plots evaluated agreement between the imaging modalities. Transverse ultrasound thickness measures were significantly positively correlated with MRI middle (r=.67, P≤.05) and posterior thicknesses (r=.49, P≤.05) while the middle and posterior longitudinal ultrasound measures were significantly correlated to their respective MRI regions (r=.67, P≤.05 & r=.59 P≤.05, respectively). There was poor absolute agreement between correlated measures with ultrasound thickness measures being between 1.9 and 2.8mm smaller than MRI measures. These results suggest that ultrasound may be a viable clinical tool to assess relative cartilage thickness in the middle and posterior medial femoral regions. However, the absolute validity of the ultrasound measure is called into question due to the larger MRI-based thickness measures. Level IV. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. A successful model to learn and implement ultrasound-guided venous catheterization in apheresis.

    PubMed

    Gopalasingam, Nigopan; Thomsen, Anna-Marie Eller; Folkersen, Lars; Juhl-Olsen, Peter; Sloth, Erik

    2017-12-01

    Apheresis treatments can be performed with peripheral venous catheters (PVC), although central venous catheters (CVC) are inserted when PVCs fail or patient with history of difficult vascular access prior to the apheresis. Ultrasound guidance for PVC has shown promising results in other settings. To investigate if ultrasound guidance for PVC could be implemented among apheresis nurses. Second, how implementation of ultrasound guidance affected the number of CVCs used for apheresis per patient. Apheresis nurses completed a systematic training program for ultrasound-guided vascular access. All independent catheterizations were registered during the implementation stage. The number of CVCs in the pre- and postimplementation stages of the ultrasound guidance was compared. Six nurses completed the training program within a median of 48 days (range 38-83 days). In 77 patients, 485 independent ultrasound-guided PVC placements were performed during the implementation stage. All apheresis treatments (485/485) were accomplished using PVCs without requiring CVC as rescue. During the preimplementation stage, 125 of 273 (45.8%) procedures required a CVC for completion of apheresis procedures; during the postimplementation stage only 30 of 227 (13.2%) procedures required a CVC (p < 0.001). In the postimplementation stage, no CVCs were placed as rescue caused by failed PVCs but were only placed for patients where the ultrasound machine was unavailable. It indicates an effective success rate of 100% for ultrasound-guided PVC use. This study showed that ultrasound guidance could be implemented among apheresis nurses as a routine tool eliminating the need of CVC as a rescue. © 2017 Wiley Periodicals, Inc.

  15. Comparison of clinical marking and ultrasound-guided injection of Botulinum type A toxin into the masseter muscles for treating bruxism and its cosmetic effects.

    PubMed

    Quezada-Gaon, Natacha; Wortsman, Ximena; Peñaloza, Osvaldo; Carrasco, Juan Eduardo

    2016-09-01

    Botulinum toxin type A has been used for treating the hypertrophy of the masseter muscles and its cosmetic effects. Ultrasound is increasingly used in dermatology, along with the guidance of mini-invasive procedures. To evaluate the role of ultrasound for guiding the application of Botulinum A toxin in patients with cosmetic alterations due to bruxism, correlate the clinical landmarks with the ultrasound findings, and study the effect on the symptoms, cosmetics, and quality of life. Twenty individuals with bruxism and cosmetic alterations underwent an ultrasound-guided injection of Botulinum toxin type A in each masseter muscle. Clinical and ultrasound marking of the procedure was compared. Clinical and sonographic evaluation was performed at the time of injection and 3 months later. Ten normal individuals underwent ultrasound of the masseter muscles as a control group. Up to 65% of individuals showed anatomical variants of the salivary glands. The method for clinically marking the skin showed a frequently erroneous location of the anterior point (up to 40% of cases) that was proven by ultrasound to be out of the muscle. In 20% of cases, ultrasound showed that the needle should be longer to enter the muscle. After injection, most of the patients demonstrated a decrease of the symptoms and cosmetic and quality of life improvements. Ultrasound can be a potent tool for guiding the injection of Botulinum toxin into the masseter muscles. It may contribute to a more personalized procedure, better cosmetic results, and help to avoid potential complications. © 2016 Wiley Periodicals, Inc.

  16. Rectus abdominis overuse injury in a tennis athlete treated with traumeel.

    PubMed

    Natsis, Konstantinos; Lyrtzis, Christos; Papathanasiou, Efthymia; Anastasopoulos, Nikos

    2012-01-01

    Rectus abdominis injuries are common in tennis players at all levels of competition. Traumeel(®) injection can be used for treatment of muscle strains and hematomas. A 21-year-old female tennis athlete was injured on the non-dominant rectus abdominis during the cocking phase of the service motion. She suffered from pain and tenderness. One week later, during a serve, she experienced severe pain on the contralateral side of her abdomen. Conservative treatment was performed by the team physician with rest, ice therapy and analgesics for 20 days, but she had recurrent injuries. The ultrasonography and MRI showed hematoma of the rectus abdominis muscle. She was treated with 2 injections of Traumeel(®) on the 2(nd), 4(th), 6(th) post-traumatic day and received 1 injection on the 10(th) post-traumatic day. She also modified her serve technique. On the fourth post-treatment week the athlete had pain-free function and both the MRI appearance and the size of rectus abdominal muscle were normal. She returned to her sport activities. There is no recurrence of her injury 2 years later. Rectus abdominis hematoma must be diagnosed early. Traumeel(®) injections are effective, safe and well-tolerated for the treatment of overuse injury of the rectus abdominis following strain.

  17. A Kirschner wire as a transverse-axis guide to improve acetabular cup positioning.

    PubMed

    Ishidou, Y; Hirotsu, M; Setoguchi, T; Nagano, S; Kakoi, H; Yokouchi, M; Yamamoto, T; Komiya, S

    2016-04-01

    To compare cup-positioning accuracy in total hip arthroplasty (THA) with or without use of a Kirschner wire as a transverse-axis guide for pelvic alignment. Records of 18 men and 73 women (mean age, 60 years) who underwent primary THA with (n=49) or without (n=42) use of a Kirschner wire as a transverse-axis guide for pelvic alignment were reviewed. A 2.4-mm Kirschner wire as a transversea-xis guide was inserted to the anterior superior iliac spine and was parallel to a line linking the left and right anterior superior iliac spine. The safe zone for cup positioning was defined as 30º to 50° abduction and 10º to 30º anteversion. Of the 5 operative surgeons, 2 were classified as experienced (total surgical volume >300) and 3 as inexperienced (total surgical volume of <50). The proportion of patients with the cup in the safe zone was compared in patients with or without use of the transverse-axis guide and in experienced and inexperienced surgeons. For inexperienced surgeons, the use of the transverse-axis guide significantly improved the proportion of patients with the cup in the safe zone from 90% to 100% for abduction, from 50% to 82.4% for anteversion, and from 40% to 82.4% for both. Patients with the cup inside or outside the safe zone were comparable in terms of body height, weight, BMI, subcutaneous fat thickness, incision length, and acetabular cup size. The use of the transverse-axis guide improved the accuracy of cup positioning by inexperienced surgeons.

  18. Tissue elasticity of in vivo skeletal muscles measured in the transverse and longitudinal planes using shear wave elastography.

    PubMed

    Chino, Kentaro; Kawakami, Yasuo; Takahashi, Hideyuki

    2017-07-01

    The aim of the present study was to measure in vivo skeletal muscle elasticity in the transverse and longitudinal planes using shear wave elastography and then to compare the image stability, measurement values and measurement repeatability between these imaging planes. Thirty-one healthy males participated in this study. Tissue elasticity (shear wave velocity) of the medial gastrocnemius, rectus femoris, biceps brachii and rectus abdominis was measured in both the transverse and longitudinal planes using shear wave elastography. Image stability was evaluated by the standard deviation of the colour distribution in the shear wave elastography image. Measurement repeatability was assessed by the coefficient of variance obtained from three measurement values. Image stability of all tested muscles was significantly higher in the longitudinal plane (P<0·001), but measurement repeatability did not differ significantly between the imaging planes (P>0·05), except in the biceps brachii (P = 0·001). Measurement values of the medial gastrocnemius, rectus femoris and biceps brachii were significantly different between the imaging planes (P<0·001). Image stability and measurement values of shear wave elastography images varied with imaging plane, which indicates that imaging plane should be considered when measuring skeletal muscle tissue elasticity by shear wave elastography. © 2015 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  19. Ultrasound-guided injection of triamcinolone and bupivacaine in the management of De Quervain's disease.

    PubMed

    Jeyapalan, Kanagaratnam; Choudhary, Surabhi

    2009-11-01

    The aim of this study was to describe the technique and usefulness of ultrasound-guided intrasynovial injection of triamcinolone and bupivacaine in treatment of de Quervain's disease. A total of 17 patients with symptomatic De Quervain's disease were included in this study. The procedure involved confirmation of diagnosis with ultrasound followed by guided injection of a mixture of 20 mg of triamcinolone (40 mg/ml) and 1 ml of 0.5% bupivacaine. Ultrasound guidance with a high resolution 15-Mhz footprint probe was used for injection into the first dorsal extensor compartment tendon sheath (E1). The response to ultrasound-guided injection was ascertained at the post procedure outpatient clinic appointment according to the follow-up clinic notes. There were 14 female and 3 male patients aged 29 to 74 years. Mean duration of symptoms was 8.9 months. One patient had an atypical septum in the first extensor compartment and the extensor pollicis brevis alone was involved. The mean post-injection follow-up was at 6.75 weeks. One patient was lost to follow-up. Fifteen out of 16 patients had significant symptomatic relief (93.75%). There were no immediate or delayed complications. Recurrence of symptoms was seen in 3 (20%) patients. Ultrasound-guided injection of triamcinolone and bupivacaine is safe and useful in controlling symptoms of De Quervain's disease. Correct needle placement with ultrasound guidance avoids intratendinous injection as well as local complications like fat atrophy and depigmentation.

  20. Treatment of Parkinson's disease in rats by Nrf2 transfection using MRI-guided focused ultrasound delivery of nanomicrobubbles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Long, Ling; Cai, Xiaodong; Guo, Ruomi

    Parkinson's disease (PD) is a very common neurological disorder. However, effective therapy is lacking. Although the blood-brain-barrier (BBB) protects the brain, it prevents the delivery of about 90% of drugs and nucleotides into the brain, thereby hindering the development of gene therapy for PD. Magnetic resonance imaging (MRI)-guided focused ultrasound delivery of microbubbles enhances the delivery of gene therapy vectors across the BBB and improves transfection efficiency. In the present study, we delivered nuclear factor E2-related factor 2 (Nrf2, NFE2L2) contained in nanomicrobubbles into the substantia nigra of PD rats by MRI-guided focused ultrasound, and we examined the effect ofmore » Nrf2 over-expression in this animal model of PD. The rat model of PD was established by injecting 6-OHDA in the right substantia nigra stereotactically. Plasmids (pDC315 or pDC315/Nrf2) were loaded onto nanomicrobubbles, and then injected through the tail vein with the assistance of MRI-guided focused ultrasound. MRI-guided focused ultrasound delivery of nanomicrobubbles increased gene transfection efficiency. Furthermore, Nrf2 gene transfection reduced reactive oxygen species levels, thereby protecting neurons in the target region. - Highlights: • MRI-guided focused ultrasound enhances gene transfection into the brain of rats. • Increased Nrf2 expression protects neurons in the rat model of PD. • Nrf2 protects neurons in PD by inhibiting ROS production.« less

  1. Disinfection of a probe used in ultrasound-guided prostate biopsy.

    PubMed

    Rutala, William A; Gergen, Maria F; Weber, David J

    2007-08-01

    Transrectal ultrasound (TRUS)-guided prostate biopsies are among the most common outpatient diagnostic procedures in urology clinics and carry the risk of introducing pathogens that may lead to infection. To investigate the effectiveness of procedures for disinfecting a probe used in ultrasound-guided prostate biopsy. The effectiveness of disinfection was determined by inoculating 10(7) colony forming units (cfu) of Pseudomonas aeruginosa at the following 3 sites on the probe: the interior lumen of the biopsy needle guide, the outside surface of the biopsy needle guide, and the interior lumen of the ultrasound probe where the needle guide passes through the transducer. Each site was investigated separately. After inoculation, the probe was immersed in 2% glutaraldehyde for 20 minutes and then assessed for the level of microbial contamination. The results demonstrated that disinfection (ie, a reduction in bacterial load of greater than 7 log(10) cfu) could be achieved if the needle guide was removed from the probe. However, if the needle guide was left in the probe channel during immersion in 2% glutaraldehyde, disinfection was not achieved (ie, the reduction was approximately 1 log(10) cfu). Recommendations for probe disinfection are provided and include disassembling the device and immersing the probe and the needle guide separately in a high-level disinfectant.

  2. The effect of core stability and general exercise on abdominal muscle thickness in non-specific chronic low back pain using ultrasound imaging.

    PubMed

    Shamsi, MohammadBagher; Sarrafzadeh, Javad; Jamshidi, Aliashraf; Zarabi, Vida; Pourahmadi, Mohammad Reza

    2016-05-01

    There is a controversy regarding whether core stability exercise (CSE) is more effective than general exercise (GE) for chronic LBP. To compare different exercises regarding their effect on improving back strength and stability, performance of abdominal muscles is a useful index. Ultrasound imaging for measuring muscle thickness could be used to assess muscle performance. The aim of this study was to compare CSE and GE in chronic LBP using ultrasound imaging for measurement of thickness of the deep stabilizing and main global trunk muscles in non-specific chronic LBP. Each program included 16 training sessions three times a week. Using ultrasound imaging, four transabdominal muscle thickness were measured before and after the intervention. Disability and pain were measured as secondary outcomes. After the intervention on participants (n = 43), a significant increase in muscle thickness (hypertrophy) was seen only in right and left rectus abdominis in the GE group, but significant difference to the CSE group was only on the right side. Disability and pain reduced within the groups without a significant difference in the change between them. The present results provided evidence that only GE increased right and left rectus muscle thickness. The only significant difference between CSE and GE groups was the right rectus thickness. As rectus is a global muscle, the effect of GE on strength improvement (one side stronger than the other) may have a negative effect on motor control of lumbopelvic muscles and possibly increase the risk of back pain occurring or becoming worse, though this was not observed in the present study.

  3. Prospective evaluation of magnetic resonance imaging guided in-bore prostate biopsy versus systematic transrectal ultrasound guided prostate biopsy in biopsy naïve men with elevated prostate specific antigen.

    PubMed

    Quentin, Michael; Blondin, Dirk; Arsov, Christian; Schimmöller, Lars; Hiester, Andreas; Godehardt, Erhard; Albers, Peter; Antoch, Gerald; Rabenalt, Robert

    2014-11-01

    Magnetic resonance imaging guided biopsy is increasingly performed to diagnose prostate cancer. However, there is a lack of well controlled, prospective trials to support this treatment method. We prospectively compared magnetic resonance imaging guided in-bore biopsy with standard systematic transrectal ultrasound guided biopsy in biopsy naïve men with increased prostate specific antigen. We performed a prospective study in 132 biopsy naïve men with increased prostate specific antigen (greater than 4 ng/ml). After 3 Tesla functional multiparametric magnetic resonance imaging patients were referred for magnetic resonance imaging guided in-bore biopsy of prostate lesions (maximum 3) followed by standard systematic transrectal ultrasound guided biopsy (12 cores). We analyzed the detection rates of prostate cancer and significant prostate cancer (greater than 5 mm total cancer length or any Gleason pattern greater than 3). A total of 128 patients with a mean ± SD age of 66.1 ± 8.1 years met all study requirements. Median prostate specific antigen was 6.7 ng/ml (IQR 5.1-9.0). Transrectal ultrasound and magnetic resonance imaging guided biopsies provided the same 53.1% detection rate, including 79.4% and 85.3%, respectively, for significant prostate cancer. Magnetic resonance imaging and transrectal ultrasound guided biopsies missed 7.8% and 9.4% of clinically significant prostate cancers, respectively. Magnetic resonance imaging biopsy required significantly fewer cores and revealed a higher percent of cancer involvement per biopsy core (each p <0.01). Combining the 2 methods provided a 60.9% detection rate with an 82.1% rate for significant prostate cancer. Magnetic resonance imaging guided in-bore and systematic transrectal ultrasound guided biopsies achieved equally high detection rates in biopsy naïve patients with increased prostate specific antigen. Magnetic resonance imaging guided in-bore biopsies required significantly fewer cores and revealed a significantly higher percent of cancer involvement per biopsy core. Copyright © 2014 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  4. In-Bore MR-Guided Biopsy Systems and Utility of PI-RADS.

    PubMed

    Fütterer, Jurgen J; Moche, Michael; Busse, Harald; Yakar, Derya

    2016-06-01

    A diagnostic dilemma exists in cases wherein a patient with clinical suspicion for prostate cancer has a negative transrectal ultrasound-guided biopsy session. Although transrectal ultrasound-guided biopsy is the standard of care, a paradigm shift is being observed. In biopsy-naive patients and patients with at least 1 negative biopsy session, multiparametric magnetic resonance imaging (MRI) is being utilized for tumor detection and subsequent targeting. Several commercial devices are now available for targeted prostate biopsy ranging from transrectal ultrasound-MR fusion biopsy to in bore MR-guided biopsy. In this review, we will give an update on the current status of in-bore MRI-guided biopsy systems and discuss value of prostate imaging-reporting and data system (PIRADS).

  5. MR-Guided Pulsed High-Intensity Focused Ultrasound Enhancement of Gene Therapy Combined With Androgen Deprivation and Radiotherapy for Prostate Cancer Treatment

    DTIC Science & Technology

    2009-09-01

    first statement of work is to determine if high intensity focused ultrasound ( HIFU ) increases the cellular uptake of AS-MDM2, AS-bcl-2 and AS-PKA...Drug Delivery in Prostate Tumor in vivo Using MR Guided Focused Ultrasound (MRg HIFU ). WC, IFMBE Proceedings 25: pp341-344, 2009 6...pharmaceutical agents in the treatment target. In the model system proposed, pulsed high intensity focused ultrasound ( HIFU ) is hypothesized to improve

  6. The role of ultrasound guidance in pediatric caudal block

    PubMed Central

    Erbüyün, Koray; Açıkgöz, Barış; Ok, Gülay; Yılmaz, Ömer; Temeltaş, Gökhan; Tekin, İdil; Tok, Demet

    2016-01-01

    Objectives: To compare the time interval of the procedure, possible complications, post-operative pain levels, additional analgesics, and nurse satisfaction in ultrasonography-guided and standard caudal block applications. Methods: This retrospective study was conducted in Celal Bayar University Hospital, Manisa, Turkey, between January and December 2014, included 78 pediatric patients. Caudal block was applied to 2 different groups; one with ultrasound guide, and the other using the standard method. Results: The time interval of the procedure was significantly shorter in the standard application group compared with ultrasound-guided group (p=0.020). Wong-Baker FACES Pain Rating Scale values obtained at the 90th minute was statistically lower in the standard application group compared with ultrasound-guided group (p=0.035). No statistically significant difference was found on the other parameters between the 2 groups. The shorter time interval of the procedure at standard application group should not be considered as a distinctive mark by the pediatric anesthesiologists, because this time difference was as short as seconds. Conclusion: Ultrasound guidance for caudal block applications would neither increase nor decrease the success of the treatment. However, ultrasound guidance should be needed in cases where the detection of sacral anatomy is difficult, especially by palpations. PMID:26837396

  7. Sonothrombolysis of Intra-Catheter Aged Venous Thrombi Using Microbubble Enhancement and Guided Three Dimensional Ultrasound Pulses

    PubMed Central

    Kutty, Shelby; Xie, Feng; Gao, Shunji; Drvol, Lucas K; Lof, John; Fletcher, Scott E; Radio, Stanley J; Danford, David A; Hammel, James M; Porter, Thomas R

    2010-01-01

    Central venous and arterial catheters are a major source of thrombo-embolic disease in children. We hypothesized that guided high mechanical index (MI) impulses from diagnostic three-dimensional (3D) ultrasound during an intravenous microbubble infusion could dissolve these thrombi. An in vitro system simulating intra-catheter thrombi was created and then treated with guided high MI impulses from 3D ultrasound, utilizing low MI microbubble sensitive imaging pulse sequence schemes to detect the microbubbles (Perflutren Lipid Microsphere, Definity®, Lantheus). Ten aged thrombi over 24 hours old were tested using 3D ultrasound coupled with a continuous diluted microbubble infusion (Group A), and ten with 3D ultrasound alone (Group B). Mean thrombus age was 28.6 hours (range 26.6–30.3). Groups A exhibited a 55 ± 19 % reduction in venous thrombus size, compared to 31±10 % for Group B (p=0.008). Feasibility testing was performed in 4 pigs, establishing a model to further investigate the efficacy. Sonothrombolysis of aged intra-catheter venous thrombi can be achieved with commercially available microbubbles and guided high MI ultrasound from a diagnostic 3D transducer. PMID:20696549

  8. Analysis of "dry" mesothelioma with ultrasound guided biopsies.

    PubMed

    Stigt, Jos A; Boers, James E; Groen, Harry J M

    2012-12-01

    Image-guided sampling of the thickened pleura is a sensitive approach in patients with malignant pleural mesothelioma with pleural effusion. Malignant pleural mesothelioma presenting without effusion however is more of a diagnostic challenge. In this study we report the diagnostic yield and complications of ultrasound-guided cutting needle biopsies in this particular category of patients. A retrospective database analysis from September 2007 until January 2012 was performed in 56 patients with malignant pleural mesothelioma. Clinical characteristics and results of diagnostic evaluations were analysed. Of the 56 patients with malignant pleural mesothelioma, 20 patients presented without pleural effusion of with locular effusion. Ultrasound-guided cutting needle biopsy was performed in 14/20 patients with a diagnostic accuracy of 80%. Only 1 patient had mild haemoptysis immediately following biopsies. Diagnosing patients with pleural thickenings suspect for malignant mesothelioma without pleural effusion or with loculated pleural effusion is effective and safe with ultrasound-guided cutting needle biopsies. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  9. Ultrasound-Guided Treatment of Peripheral Nerve Pathology.

    PubMed

    Dettori, Nathan; Choudur, Hema; Chhabra, Avneesh

    2018-07-01

    High-resolution ultrasound serves as a fast, accessible, reliable, and radiation-free tool for anatomical and dynamic evaluation of various peripheral nerves. It can be used not only to identify and diagnose peripheral nerve and perineural pathology accurately but also to guide various nerve and perineural interventions. We describe the normal and pathologic appearances of peripheral nerves, the pathologies commonly affecting the individual peripheral nerves, and the current ultrasound-guided peripheral nerve interventions and techniques. Future directions are also highlighted. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  10. Impact of Focused Ultrasound-enhanced Drug Delivery on Survival in Rats with Glioma

    NASA Astrophysics Data System (ADS)

    Treat, Lisa Hsu; Zhang, Yongzhi; McDannold, Nathan; Hynynen, Kullervo

    2009-04-01

    Malignancies of the brain remain difficult to treat with chemotherapy because the selective permeability of the blood-brain barrier (BBB) blocks many potent agents from reaching their target. Previous studies have illustrated the feasibility of drug and antibody delivery across the BBB using MRI-guided focused ultrasound. In this study, we investigated the impact of focused ultrasound-enhanced delivery of doxorubicin on survival in rats with aggressive glioma. Sprague-Dawley rats were implanted with 9 L gliosarcoma cells in the brain. Eight days after implantation, each rat received one of the following: (1) no treatment (control), (2) a single treatment with microbubble-enhanced MRI-guided focused ultrasound (FUS only), (3) a single treatment with i.v. liposomal doxorubicin (DOX only), or (4) a single treatment with microbubble-enhanced MRI-guided focused ultrasound and concurrent i.v. injections of liposomal doxorubicin (FUS+DOX). The survival time from implantation to death or euthanasia was recorded. We observed a modest but significant increase in median survival time in rats treated with combined MRI-guided focused ultrasound chemotherapy, compared to chemotherapy alone (p<0.001). There was no significant improvement in survival between those who received stand-alone chemotherapy and those who did not receive any treatment (p>0.10). Our study demonstrates for the first time a therapeutic benefit achieved with ultrasound-enhanced drug delivery across the blood-brain barrier. This confirmation of efficacy in an in vivo tumor model indicates that targeted drug delivery using MRI-guided focused ultrasound has the potential to have a major impact on the treatment of patients with brain tumors and other neurological disorders.

  11. Long-axis view for ultrasound-guided central venous catheter placement via the internal jugular vein.

    PubMed

    Mahan, Angel F; McEvoy, Matthew D; Gravenstein, Nikolaus

    2016-04-01

    In modern practice, real-time ultrasound guidance is commonly employed for the placement of internal jugular vein catheters. With a new tool, such as ultrasound, comes the opportunity to refine and further optimize the ultrasound view during jugular vein catheterization. We describe jugular vein access techniques and use the long-axis view as an alternative to the commonly employed short-axis cross-section view for internal jugular vein access and cannulation. The long-axis ultrasound-guided internal jugular vein approach for internal jugular vein cannulation is a useful alternative technique that can provide better needle tip and guidewire visualization than the more traditional short-axis ultrasound view.

  12. [Carpal canal ultrasound examination in patients with mild hand-arm vibration disease].

    PubMed

    Liu, Y Z; Ye, Z H; Yang, W L; Zhu, J X; Lu, Q J; Su, W L

    2016-08-20

    Objective: To investigate the clinical value of ultrasound examination of carpal canal structure in patients with mild hand-arm vibration disease. Methods: A total of 29 patients (58 wrists) with mild hand-arm vibration disease who were treated in Shenzhen Prevention and Treatment Center for Occupational Diseases from May to December, 2015 were enrolled as observation group, and 20 healthy volunteers (40 wrists) were enrolled as the control group. Color Doppler ultrasound was used to observe the morphology and echo of the median nerve in the carpal canal and 9 muscle tendons and transverse carpal ligament. The thickness of transverse carpal ligament and diameter of the median nerve at the level of the hamulus of hamate bone were measured, as well as the cross-sectional area of the median nerve at the level of pisiform bone. Results: In the 29 patients with hand-arm vibration disease patients in the observation group, 8 experienced entrapment of the median nerve in the carpal canal, among whom 5 had entrapment in both wrists; there were 13 wrists (23%) with nerve entrapment and 45 wrists (77%) without nerve entrapment. Compared with the control group, the patients with hand-arm vibration disease and nerve entrapment in the observation group showed significant thickening of the transverse carpal ligament at the level of the hamulus of hamate bone and a significant increase in the cross-sectional area of the median nerve at the level of pisiform bone ( P <0.05) , while there were no significant differences in the thickness of transverse carpal ligament at the level of the hamulus of hamate bone and the cross-sectional area of the median nerve at the level of pisiform bone ( t=- 9.397 and -4.385, both P >0.05) . Conclusion: Ultrasound examination can clearly show the radiological changes of carpal canal contents in patients with mild hand-arm vibration disease and has a certain diagnostic value in nerve damage in patients with hand-arm vibration disease.

  13. WE-G-12A-01: High Intensity Focused Ultrasound Surgery and Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Farahani, K; O'Neill, B

    More and more emphasis is being made on alternatives to invasive surgery and the use of ionizing radiation to treat various diseases including cancer. Novel screening, diagnosis, treatment and monitoring of response to treatment are also hot areas of research and new clinical technologies. Ultrasound(US) has gained traction in all of the aforementioned areas of focus. Especially with recent advances in the use of ultrasound to noninvasively treat various diseases/organ systems. This session will focus on covering MR-guided focused ultrasound and the state of the art clinical applications, and the second speaker will survey the more cutting edge technologies e.g.more » Focused Ultrasound (FUS) mediated drug delivery, principles of cavitation and US guided FUS. Learning Objectives: Fundamental physics and physical limitations of US interaction with tissue and nanoparticles The alteration of tissue transport using focused ultrasound US control of nanoparticle drug carriers for targeted release The basic principles of MRI-guided focused ultrasound (MRgFUS) surgery and therapy the current state of the art clinical applications of MRgFUS requirements for quality assurance and treatment planning.« less

  14. Ultrasound-Guided Single-Injection Infraclavicular Block Versus Ultrasound-Guided Double-Injection Axillary Block: A Noninferiority Randomized Controlled Trial.

    PubMed

    Boivin, Ariane; Nadeau, Marie-Josée; Dion, Nicolas; Lévesque, Simon; Nicole, Pierre C; Turgeon, Alexis F

    2016-01-01

    Single-injection ultrasound-guided infraclavicular block is a simple, reliable, and effective technique. A simplified double-injection ultrasound-guided axillary block technique with a high success rate recently has been described. It has the advantage of being performed in a superficial and compressible location, with a potentially improved safety profile. However, its effectiveness in comparison with single-injection infraclavicular block has not been established. We hypothesized that the double-injection ultrasound-guided axillary block would show rates of complete sensory block at 30 minutes noninferior to the single-injection ultrasound-guided infraclavicular block. After approval by our research ethics committee and written informed consent, adults undergoing distal upper arm surgery were randomized to either group I, ultrasound-guided single-injection infraclavicular block, or group A, ultrasound-guided double-injection axillary block. In group I, 30 mL of 1.5% mepivacaine was injected posterior to the axillary artery. In group A, 25 mL of 1.5% mepivacaine was injected posteromedial to the axillary artery, after which 5 mL was injected around the musculocutaneous nerve. Primary outcome was the rate of complete sensory block at 30 minutes. Secondary outcomes were the onset of sensory and motor blocks, surgical success rates, performance times, and incidence of complications. All outcomes were assessed by a blinded investigator. The noninferiority of the double-injection ultrasound-guided axillary block was considered if the limits of the 90% confidence intervals (CIs) were within a 10% margin of the rate of complete sensory block of the infraclavicular block. At 30 minutes, the rate of complete sensory block was 79% in group A (90% CI, 71%-85%) compared with 91% in group I (90% CI, 85%-95%); the upper limit of CI of group A is thus included in the established noninferiority margin of 10%. The rate of complete sensory block was lower in group A (proportion difference of 12% [95% CI, 2-22]; P = 0.0091), as was surgical success rate (82% [95% CI, 74%-89%] vs 93% [95% CI, 86%-97%]; proportion difference of 11% [95% CI 1-20]; P = 0.0153). Sensory block onset also was slower in group A (log rank test P = 0.0020). Performance times were faster in group I (231 seconds [95% CI, 213-250]) than in group A (358 seconds [95% CI, 332-387]; P < 0.0001). No statistically significant difference was observed for vascular puncture, paresthesia during block performance, or procedure-related pain. No neurologic complication was noted at follow-up. We failed to demonstrate that the rate of complete sensory block of the double-injection axillary block is noninferior to the single-injection infraclavicular block. However, the rate of complete sensory block at 30 minutes is statistically significantly lower with the axillary block. The ultrasound-guided single-injection infraclavicular block thus seems to be the preferred technique over the axillary for upper arm anesthesia.

  15. Ultrasound-Guided Percutaneous Tenotomy of Biceps Tendon: Technical Feasibility on Cadavers.

    PubMed

    Sconfienza, Luca Maria; Mauri, Giovanni; Messina, Carmelo; Aliprandi, Alberto; Secchi, Francesco; Sardanelli, Francesco; Randelli, Pietro Simone

    2016-10-01

    We tested the technical feasibility of ultrasound-guided percutaneous tenotomy of the long head of the biceps tendon (LHBT) in cadavers. Both shoulders of two fresh cadavers were scanned anteriorly to evaluate the extra-articular portion of the LHBT. Under ultrasound monitoring, a scalpel was advanced obliquely up to touch the superficial medial side of the LHBT, cutting it until the tendon was not visible anymore. Ultrasound evaluation was repeated after the procedure, and anatomic dissection was performed. The procedure was 100% feasible: four cuts were made to completely sever the tendon; the duration was less than 1 min. Skin incision measured 5 mm in two cases and 6 mm in two cases. Anatomic dissection confirmed complete tendon cut in all cases with proximal and distal tendon stumps very close to each other. Ultrasound-guided percutaneous LHBT tenotomy was 100% technically feasible in cadavers with a quick procedure and minimal cutaneous incision. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  16. A multimodal image guiding system for Navigated Ultrasound Bronchoscopy (EBUS): A human feasibility study

    PubMed Central

    Hofstad, Erlend Fagertun; Amundsen, Tore; Langø, Thomas; Bakeng, Janne Beate Lervik; Leira, Håkon Olav

    2017-01-01

    Background Endobronchial ultrasound transbronchial needle aspiration (EBUS-TBNA) is the endoscopic method of choice for confirming lung cancer metastasis to mediastinal lymph nodes. Precision is crucial for correct staging and clinical decision-making. Navigation and multimodal imaging can potentially improve EBUS-TBNA efficiency. Aims To demonstrate the feasibility of a multimodal image guiding system using electromagnetic navigation for ultrasound bronchoschopy in humans. Methods Four patients referred for lung cancer diagnosis and staging with EBUS-TBNA were enrolled in the study. Target lymph nodes were predefined from the preoperative computed tomography (CT) images. A prototype convex probe ultrasound bronchoscope with an attached sensor for position tracking was used for EBUS-TBNA. Electromagnetic tracking of the ultrasound bronchoscope and ultrasound images allowed fusion of preoperative CT and intraoperative ultrasound in the navigation software. Navigated EBUS-TBNA was used to guide target lymph node localization and sampling. Navigation system accuracy was calculated, measured by the deviation between lymph node position in ultrasound and CT in three planes. Procedure time, diagnostic yield and adverse events were recorded. Results Preoperative CT and real-time ultrasound images were successfully fused and displayed in the navigation software during the procedures. Overall navigation accuracy (11 measurements) was 10.0 ± 3.8 mm, maximum 17.6 mm, minimum 4.5 mm. An adequate sample was obtained in 6/6 (100%) of targeted lymph nodes. No adverse events were registered. Conclusions Electromagnetic navigated EBUS-TBNA was feasible, safe and easy in this human pilot study. The clinical usefulness was clearly demonstrated. Fusion of real-time ultrasound, preoperative CT and electromagnetic navigational bronchoscopy provided a controlled guiding to level of target, intraoperative overview and procedure documentation. PMID:28182758

  17. Feasibility of Retrograde Ureteral Contrast Injection to Guide Ultrasonographic Percutaneous Renal Access in the Nondilated Collecting System.

    PubMed

    Usawachintachit, Manint; Tzou, David T; Mongan, John; Taguchi, Kazumi; Weinstein, Stefanie; Chi, Thomas

    2017-02-01

    Ultrasound-guided percutaneous nephrolithotomy (PCNL) has become increasingly utilized. Patients with nondilated collecting systems represent a challenge: the target calix is often difficult to visualize. Here we report pilot study results for retrograde ultrasound contrast injection to aid in percutaneous renal access during ultrasound-guided PCNL. From April to July 2016, consecutive patients over the age of 18 years with nondilated collecting systems on preoperative imaging who presented for PCNL were enrolled. B-mode ultrasound imaging was compared with contrast-enhanced mode with simultaneous retrograde injection of Optison™ via an ipsilateral ureteral catheter. Five patients (four males and one female) with renal stones underwent PCNL with retrograde ultrasound contrast injection during the study period. Mean body mass index was 28.3 ± 5.6 kg/m 2 and mean stone size was 24.5 ± 12.0 mm. Under B-mode ultrasound, all patients demonstrated nondilated renal collecting systems that appeared as hyperechoic areas, where it was difficult to identify a target calix for puncture. Retrograde contrast injection facilitated delineation of all renal calices initially difficult to visualize under B-mode ultrasound. Renal puncture was then performed effectively in all cases with a mean puncture time of 55.4 ± 44.8 seconds. All PCNL procedures were completed without intraoperative complications and no adverse events related to ultrasound contrast injection occurred. Retrograde ultrasound contrast injection as an aide for renal puncture during PCNL is a feasible technique. By improving visualization of the collecting system, it facilitates needle placement in challenging patients without hydronephrosis. Future larger scale studies comparing its use to standard ultrasound-guided technique will be required to validate this concept.

  18. Success of ultrasound-guided versus landmark-guided arthrocentesis of hip, ankle, and wrist in a cadaver model.

    PubMed

    Berona, Kristin; Abdi, Amin; Menchine, Michael; Mailhot, Tom; Kang, Tarina; Seif, Dina; Chilstrom, Mikaela

    2017-02-01

    The objectives of this study were to evaluate emergency medicine resident-performed ultrasound for diagnosis of effusions, compare the success of a landmark-guided (LM) approach with an ultrasound-guided (US) technique for hip, ankle and wrist arthrocentesis, and compare change in provider confidence with LM and US arthrocentesis. After a brief video on LM and US arthrocentesis, residents were asked to identify artificially created effusions in the hip, ankle and wrist in a cadaver model and to perform US and LM arthrocentesis of the effusions. Outcomes included success of joint aspiration, time to aspiration, and number of attempts. Residents were surveyed regarding their confidence in identifying effusions with ultrasound and performing LM and US arthrocentesis. Eighteen residents completed the study. Sensitivity of ultrasound for detecting joint effusion was 86% and specificity was 90%. Residents were successful with ultrasound in 96% of attempts and with landmark 89% of attempts (p=0.257). Median number of attempts was 1 with ultrasound and 2 with landmarks (p=0.12). Median time to success with ultrasound was 38s and 51s with landmarks (p=0.23). After the session, confidence in both US and LM arthrocentesis improved significantly, however the post intervention confidence in US arthrocentesis was higher than LM (4.3 vs. 3.8, p<0.001). EM residents were able to successfully identify joint effusions with ultrasound, however we were unable to detect significant differences in actual procedural success between the two modalities. Further studies are needed to define the role of ultrasound for arthrocentesis in the emergency department. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Pathological fracture of the patella due to an atypical located aneurysmal bone cyst: verification by means of ultrasound-guided biopsy.

    PubMed

    Plaikner, Michaela; Gruber, Hannes; Henninger, Benjamin; Gruber, Leonhard; Kosiol, Juana; Loizides, Alexander

    2016-03-01

    We report on a rare case of an atypical located aneurysmal bone cyst (ABC) in the patella presenting with pathological fracture after trauma. Using all available diagnostic modalities and by means of ultrasound-guided core-needle biopsy an unclear and suspected pathological fractured cystic bone lesion in the patella of a young man could be further clarified. The acquired images suggested the diagnosis of a pathological fractured aneurysmal bone cyst after mild trauma. However, due to the extraordinary location and clinical presentation the diagnosis was secured by means of ultrasound-guided biopsy through a small cortical gap. As shown in this rare case of an atypical aneurysmal bone cyst of the patella, the quite seldom but sometimes possible ultrasound-guided biopsy of intraosseous lesions can help to achieve the diagnostic clarification and should also be taken into account as a non-standard procedure.

  20. Ultrasound-guided percutaneous injection of methylene blue to identify nerve pathology and guide surgery.

    PubMed

    Osorio, Joseph A; Breshears, Jonathan D; Arnaout, Omar; Simon, Neil G; Hastings-Robinson, Ashley M; Aleshi, Pedram; Kliot, Michel

    2015-09-01

    OBJECT The objective of this study was to provide a technique that could be used in the preoperative period to facilitate the surgical exploration of peripheral nerve pathology. METHODS The authors describe a technique in which 1) ultrasonography is used in the immediate preoperative period to identify target peripheral nerves, 2) an ultrasound-guided needle electrode is used to stimulate peripheral nerves to confirm their position, and then 3) a methylene blue (MB) injection is performed to mark the peripheral nerve pathology to facilitate surgical exploration. RESULTS A cohort of 13 patients with varying indications for peripheral nerve surgery is presented in which ultrasound guidance, stimulation, and MB were used to localize and create a road map for surgeries. CONCLUSIONS Preoperative ultrasound-guided MB administration is a promising technique that peripheral nerve surgeons could use to plan and execute surgery.

  1. Comparison of analgesic efficacy of four-quadrant transversus abdominis plane (TAP) block and continuous posterior TAP analgesia with epidural analgesia in patients undergoing laparoscopic colorectal surgery: an open-label, randomised, non-inferiority trial.

    PubMed

    Niraj, G; Kelkar, A; Hart, E; Horst, C; Malik, D; Yeow, C; Singh, B; Chaudhri, S

    2014-04-01

    Posterior transversus abdominis plane blocks have been reported to be an effective method of providing analgesia after lower abdominal surgery. We compared the efficacy of a novel technique of providing continuous transversus abdominis plane analgesia with epidural analgesia in patients on an enhanced recovery programme following laparoscopic colorectal surgery. A non-inferiority comparison was used. Adult patients undergoing elective laparoscopic colorectal surgery were randomly assigned to receive continuous transversus abdominis plane analgesia (n = 35) vs epidural analgesia (n = 35), in addition to a postoperative analgesic regimen comprising regular paracetamol, regular diclofenac and tramadol as required. Sixty-one patients completed the study. The transversus group received four-quadrant transversus abdominis plane blocks and bilateral posterior transversus abdominis plane catheters that were infused with levobupivacaine 0.25% for 48 h. The epidural group received an infusion of bupivacaine and fentanyl. The primary outcome measure was visual analogue scale pain score on coughing at 24 h after surgery. We found no significant difference in median (IQR [range]) visual analogue scores during coughing at 24 h between the transversus group 2.5 (1.0-3.0 [0-5.5]) and the epidural group 2.5 (1.0-5.0 [0-6.0]). The one-sided 97.5% CI was a 0.0 (∞-1.0) difference in means, establishing non-inferiority. There were no significant differences between the groups for tramadol consumption. Success rate was 28/30 (93%) in the transversus group vs 27/31 (87%) in the epidural group. Continuous transversus abdominis plane infusion was non-inferior to epidural infusion in providing analgesia after laparoscopic colorectal surgery. © 2013 The Association of Anaesthetists of Great Britain and Ireland.

  2. Ultrasound image-guided therapy enhances antitumor effect of cisplatin.

    PubMed

    Sasaki, Noboru; Kudo, Nobuki; Nakamura, Kensuke; Lim, Sue Yee; Murakami, Masahiro; Kumara, W R Bandula; Tamura, Yu; Ohta, Hiroshi; Yamasaki, Masahiro; Takiguchi, Mitsuyoshi

    2014-01-01

    The aim of this study was to clarify whether ultrasound image-guided cisplatin delivery with an intratumor microbubble injection enhances the antitumor effect in a xenograft mouse model. Canine thyroid adenocarcinoma cells were used for all experiments. Before in vivo experiments, the cisplatin and microbubble concentration and ultrasound exposure time were optimized in vitro. For in vivo experiments, cells were implanted into the back of nude mice. Observed by a diagnostic ultrasound machine, a mixture of cisplatin and ultrasound contrast agent, Sonazoid, microbubbles was injected directly into tumors. The amount of injected cisplatin and microbubbles was 1 μg/tumor and 1.2 × 10(7) microbubbles/tumor, respectively, with a total injected volume of 20 μl. Using the same diagnostic machine, tumors were exposed to ultrasound for 15 s. The treatment was repeated four times. The combination of cisplatin, microbubbles, and ultrasound significantly delayed tumor growth as compared with no treatment (after 18 days, 157 ± 55 vs. 398 ± 49 mm(3), P = 0.049). Neither cisplatin alone nor the combination of cisplatin and ultrasound delayed tumor growth. The treatment did not decrease the body weight of mice. Ultrasound image-guided anticancer drug delivery may enhance the antitumor effects of drugs without obvious side effects.

  3. The Utility of Teleultrasound to Guide Acute Patient Management.

    PubMed

    Becker, Christian; Fusaro, Mario; Patel, Dhruv; Shalom, Isaac; Frishman, William H; Scurlock, Corey

    Ultrasound has evolved into a core bedside tool for diagnostic and management purposes for all subsets of adult and pediatric critically-ill patients. Teleintensive care unit coverage has undergone a similar rapid expansion period throughout the United States. Round-the-clock access to ultrasound equipment is very common in today's intensive care unit, but 24/7 coverage with staff trained to acquire and interpret point-of-care ultrasound in real time is lagging behind equipment availability. Medical trainees and physician extenders require attending level supervision to ensure consistent image acquisition and accurate interpretation. Teleintensivists can extend the utility of ultrasound by supervising and guiding providers without or with only partial training in ultrasound, and also by extending direct trainee ultrasound supervision to time periods when no direct bedside attending supervisor is available, and when treatment decisions otherwise would have been made without supervision and feedback on image acquisition and interpretation. Nursing staff without ultrasound training can also be directed to perform basic ultrasound exams, which may have immediate diagnostic and/or treatment consequences, thereby overcoming access barriers in the absence of physicians or physician extenders. We discuss 4 real-life clinical scenarios in which teleintensivist supervision extended and standardized bedside ultrasound exams to guide management decisions which significantly impacted patient outcomes.

  4. Ultrasound criteria and guided fine-needle aspiration diagnostic yields in small animal peritoneal, mesenteric and omental disease.

    PubMed

    Feeney, Daniel A; Ober, Christopher P; Snyder, Laura A; Hill, Sara A; Jessen, Carl R

    2013-01-01

    Peritoneal, mesenteric, and omental diseases are important causes of morbidity and mortality in humans and animals, although information in the veterinary literature is limited. The purposes of this retrospective study were to determine whether objectively applied ultrasound interpretive criteria are statistically useful in differentiating among cytologically defined normal, inflammatory, and neoplastic peritoneal conditions in dogs and cats. A second goal was to determine the cytologically interpretable yield on ultrasound-guided, fine-needle sampling of peritoneal, mesenteric, or omental structures. Sonographic criteria agreed upon by the authors were retrospectively and independently applied by two radiologists to the available ultrasound images without knowledge of the cytologic diagnosis and statistically compared to the ultrasound-guided, fine-needle aspiration cytologic interpretations. A total of 72 dogs and 49 cats with abdominal peritoneal, mesenteric, or omental (peritoneal) surface or effusive disease and 17 dogs and 3 cats with no cytologic evidence of inflammation or neoplasia were included. The optimized, ultrasound criteria-based statistical model created independently for each radiologist yielded an equation-based diagnostic category placement accuracy of 63.2-69.9% across the two involved radiologists. Regional organ-associated masses or nodules as well as aggregated bowel and peritoneal thickening were more associated with peritoneal neoplasia whereas localized, severely complex fluid collections were more associated with inflammatory peritoneal disease. The cytologically interpretable yield for ultrasound-guided fine-needle sampling was 72.3% with no difference between species, making this a worthwhile clinical procedure. © 2013 Veterinary Radiology & Ultrasound.

  5. Thermal comparison of Infiniti OZil and Signature Ellips phacoemulsification systems.

    PubMed

    Schmutz, Joseph S; Olson, Randall J

    2010-05-01

    To determine thermal characteristics of Signature Ellips (Abbott Medical Optics) and Infiniti OZil (Alcon, Inc.) transverse ultrasound and compare both with longitudinal ultrasound in clinically relevant scenarios. Laboratory investigation. Temperature increase over baseline after 60 seconds was measured in water at positions in 90-degree increments around the sleeve near the proximal needle shaft in an artificial chamber for Ellips and OZil on continuous ultrasound with aspiration blocked and unblocked. This was also done with Signature using longitudinal ultrasound, with and without micropulse (6 ms on, 12 ms off), with aspiration blocked and unblocked, and at the OZil sleeve tip on continuous transverse mode with aspiration unblocked. OZil (8.1 +/- 0.3 C) had greater temperature increase than Ellips (5.2 +/- 0.3 C; P < .0001) with aspiration unblocked and blocked (29.3 +/- 1.0 C vs 12.2 +/- 0.7 C; P < .0001). OZil had uneven distribution of heat around the shaft (30.1 +/- 0.5 C vs 28.5 +/- 0.6 C; P < .0001), whereas Ellips did not (P = .57). OZil was cooler at the tip (6.6 +/- 0.2 C; P < .0001). Friction in a cadaver eye incision only increased these numbers by 10% (OZil, irrigation blocked). Metal stress probably creates heat at the proximal needle junction for both transverse methods. Heat generation differences between OZil and Ellips result from the manner in which they create needle motion. Incision burns may occur, especially for OZil, under nonpulsed settings during fragment removal with occlusion when reaching across the anterior chamber such that the proximal needle shaft came near the wound. Copyright 2010 Elsevier Inc. All rights reserved.

  6. Feasibility of Prostate Cancer Diagnosis by Transrectal Photo-acoustic Imaging

    DTIC Science & Technology

    2013-03-01

    prostate. Transrectal ultrasound has been used as a guiding tool to direct tissue needle biopsy for prostate cancer diagnosis; it cannot be utilized for...tool currently available for prostate cancer detection; needle biopsy is the current practice for diagnosis of the disease, aiming randomly in the...developing an integrated approach between ultrasound and optical tomography, namely, transrectal ultrasound - guided diffuse optical tomography (TRUS

  7. Sonoanatomy relevant for ultrasound-guided central neuraxial blocks via the paramedian approach in the lumbar region

    PubMed Central

    Karmakar, M K; Li, X; Kwok, W H; Ho, A M-H; Ngan Kee, W D

    2012-01-01

    Objectives The use of ultrasound to guide peripheral nerve blocks is now a well-established technique in regional anaesthesia. However, despite reports of ultrasound guided epidural access via the paramedian approach, there are limited data on the use of ultrasound for central neuraxial blocks, which may be due to a poor understanding of spinal sonoanatomy. The aim of this study was to define the sonoanatomy of the lumbar spine relevant for central neuraxial blocks via the paramedian approach. Methods The sonoanatomy of the lumbar spine relevant for central neuraxial blocks via the paramedian approach was defined using a “water-based spine phantom”, young volunteers and anatomical slices rendered from the Visible Human Project data set. Results The water-based spine phantom was a simple model to study the sonoanatomy of the osseous elements of the lumbar spine. Each osseous element of the lumbar spine, in the spine phantom, produced a “signature pattern” on the paramedian sagittal scans, which was comparable to its sonographic appearance in vivo. In the volunteers, despite the narrow acoustic window, the ultrasound visibility of the neuraxial structures at the L3/L4 and L4/L5 lumbar intervertebral spaces was good, and we were able to delineate the sonoanatomy relevant for ultrasound-guided central neuraxial blocks via the paramedian approach. Conclusion Using a simple water-based spine phantom, volunteer scans and anatomical slices from the Visible Human Project (cadaver) we have described the sonoanatomy relevant for ultrasound-guided central neuraxial blocks via the paramedian approach in the lumbar region. PMID:22010025

  8. Real-time ultrasound-guided spinal anesthesia using the SonixGPS® needle tracking system: a case report.

    PubMed

    Wong, Simon W; Niazi, Ahtsham U; Chin, Ki J; Chan, Vincent W

    2013-01-01

    The SonixGPS® is an electromagnetic needle tracking system for ultrasound-guided needle intervention. Both current and predicted needle tip position are displayed on the ultrasound screen in real-time, facilitating needle-beam alignment and guidance to the target. This case report illustrates the use of the SonixGPS system for successful performance of real-time ultrasound-guided spinal anesthesia in a patient with difficult spinal anatomy. A 67-yr-old male was admitted to our hospital to undergo revision of total right hip arthroplasty. His four previous arthroplasties for hip revision were performed under general anesthesia because he had undergone L3-L5 instrumentation for spinal stenosis. The L4-L5 interspace was viewed with the patient in the left lateral decubitus position. A 19G 80-mm proprietary needle (Ultrasonix Medical Corp, Richmond, BC, Canada) was inserted and directed through the paraspinal muscles to the ligamentum flavum in plane to the ultrasound beam. A 120-mm 25G Whitacre spinal needle was then inserted through the introducer needle in a conventional fashion. Successful dural puncture was achieved on the second attempt, as indicated by a flow of clear cerebrospinal fluid. The patient tolerated the procedure well, and the spinal anesthetic was adequate for the duration of the surgery. The SonixGPS is a novel technology that can reduce the technical difficulty of real-time ultrasound-guided neuraxial blockade. It may also have applications in other advanced ultrasound-guided regional anesthesia techniques where needle-beam alignment is critical.

  9. MRI-guided focused ultrasound surgery in musculoskeletal diseases: the hot topics

    PubMed Central

    Napoli, Alessandro; Sacconi, Beatrice; Battista, Giuseppe; Guglielmi, Giuseppe; Catalano, Carlo; Albisinni, Ugo

    2016-01-01

    MRI-guided focused ultrasound surgery (MRgFUS) is a minimally invasive treatment guided by the most sophisticated imaging tool available in today's clinical practice. Both the imaging and therapeutic sides of the equipment are based on non-ionizing energy. This technique is a very promising option as potential treatment for several pathologies, including musculoskeletal (MSK) disorders. Apart from clinical applications, MRgFUS technology is the result of long, heavy and cumulative efforts exploring the effects of ultrasound on biological tissues and function, the generation of focused ultrasound and treatment monitoring by MRI. The aim of this article is to give an updated overview on a “new” interventional technique and on its applications for MSK and allied sciences. PMID:26607640

  10. Gaussian representation of high-intensity focused ultrasound beams.

    PubMed

    Soneson, Joshua E; Myers, Matthew R

    2007-11-01

    A method for fast numerical simulation of high-intensity focused ultrasound beams is derived. The method is based on the frequency-domain representation of the Khokhlov-Zabolotskaya-Kuznetsov (KZK) equation, and assumes for each harmonic a Gaussian transverse pressure distribution at all distances from the transducer face. The beamwidths of the harmonics are constrained to vary inversely with the square root of the harmonic number, and as such this method may be viewed as an extension of a quasilinear approximation. The technique is capable of determining pressure or intensity fields of moderately nonlinear high-intensity focused ultrasound beams in water or biological tissue, usually requiring less than a minute of computer time on a modern workstation. Moreover, this method is particularly well suited to high-gain simulations since, unlike traditional finite-difference methods, it is not subject to resolution limitations in the transverse direction. Results are shown to be in reasonable agreement with numerical solutions of the full KZK equation in both tissue and water for moderately nonlinear beams.

  11. Outcomes of ultrasound guided renal mass biopsies.

    PubMed

    Sutherland, Edward L; Choromanska, Agnieszka; Al-Katib, Sayf; Coffey, Mary

    2018-06-01

    The purpose of this study was to evaluate the rate of nondiagnostic ultrasound-guided renal mass biopsies (RMBs) at our institution and to determine what patient, procedural, and focal renal mass (FRM) factors were associated with nondiagnostic ultrasound-guided RMBs. Eighty-two ultrasound-guided renal mass biopsies performed between January 2014 and October 2016 were included in our study. Biopsy outcomes (diagnostic vs. nondiagnostic) and patient, procedural, and FRM characteristics were retrospectively reviewed and recorded. Univariate statistical analyses were performed to identify biopsy characteristics that were indicative of nondiagnostic biopsy. Ultrasound-guided RMBs were diagnostic in 70 out of 82 cases (85%) and non-diagnostic in 12 cases (15%). Among the diagnostic biopsies, 54 (77%) were malignant cases, 94% of which were renal cell carcinoma (RCC). Of the 12 nondiagnostic cases, the final diagnosis was RCC in 4 cases and angiomyolipoma in one case; seven of the nondiagnostic cases were lost to follow-up. A weak association (p = 0.04) was found between the number of needle passes and the biopsy outcome. None of the remaining collected RMB characteristics showed a significant correlation with a diagnostic or nondiagnostic RMB. Six patients (7%) experienced complications. Ultrasound-guided renal mass biopsy is a safe and effective method for the diagnosis of renal masses with a low rate of nondiagnostic outcomes. A nondiagnostic biopsy should not be treated as a surrogate for a diagnosis since a significant number of patients with nondiagnostic biopsies have subsequently been shown to have renal malignancies. Repeat biopsy should be considered in such cases.

  12. Pre-procedure ultrasound-guided paramedian spinal anaesthesia at L5–S1: Is this better than landmark-guided midline approach? A randomised controlled trial

    PubMed Central

    Srinivasan, Karthikeyan Kallidaikurichi; Leo, Anne-Marie; Iohom, Gabriella; Loughnane, Frank; Lee, Peter J

    2018-01-01

    Background and Aims: Routine use of pre-procedural ultrasound guided midline approach has not shown to improve success rate in administering subarachnoid block. The study hypothesis was that the routine use of pre-procedural (not real time) ultrasound-guided paramedian spinals at L5-S1 interspace could reduce the number of passes (i.e., withdrawal and redirection of spinal needle without exiting the skin) required to enter the subarachnoid space when compared to the conventional landmark-guided midline approach. Methods: After local ethics approval, 120 consenting patients scheduled for elective total joint replacements (Hip and Knee) were randomised into either Group C where conventional midline approach with palpated landmarks was used or Group P where pre-procedural ultrasound was used to perform subarachnoid block by paramedian approach at L5-S1 interspace (real time ultrasound guidance was not used). Results: There was no difference in primary outcome (difference in number of passes) between the two groups. Similarly there was no difference in the number of attempts (i.e., the number of times the spinal needle was withdrawn from the skin and reinserted). The first pass success rates (1 attempt and 1 pass) was significantly greater in Group C compared to Group P [43% vs. 22%, P = 0.02]. Conclusion: Routine use of paramedian spinal anaesthesia at L5-S1 interspace, guided by pre-procedure ultrasound, in patients undergoing lower limb joint arthroplasties did not reduce the number of passes or attempts needed to achieve successful dural puncture. PMID:29416151

  13. Magnetic Resonance-Guided High-Intensity Focused Ultrasound Ablation of Osteoid Osteoma: A Case Series Report.

    PubMed

    Rovella, Marcello S; Martins, Guilherme L P; Cavalcanti, Conrado F A; Bor-Seng-Shu, Edson; Camargo, Olavo P; Cerri, Giovanni G; Menezes, Marcos R

    2016-04-01

    Osteoid osteoma is painful benign tumor. The aim of this study was to report our initial experience using magnetic resonance-guided focused ultrasound to treat osteoid osteomas. This retrospective single-center study included four patients treated with magnetic resonance-guided focused ultrasound. They presented with severe pain with reduced quality of life and a poor response to clinical treatment. The pre- and post-treatment evaluation comprised computed tomography and magnetic resonance imaging and focused on quality of life and the impact of pain on daily activities. After treatment, three patients had complete pain resolution with no recurrence. One patient had a recurrence of symptoms after 2 wk and underwent a new successful treatment with increased energy levels. On average, 13 sonications were administered (8-18 sonications/treatment) with an average energy of 2,003 J (range: 1,063-3,522 J). Magnetic resonance-guided focused ultrasound appears to be a feasible, tolerable and effective treatment in selected patients with osteoid osteomas. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  14. Hydraulic balancing of a control component within a nuclear reactor

    DOEpatents

    Marinos, D.; Ripfel, H.C.F.

    1975-10-14

    A reactor control component includes an inner conduit, for instance containing neutron absorber elements, adapted for longitudinal movement within an outer guide duct. A transverse partition partially encloses one end of the conduit and meets a transverse wall within the guide duct when the conduit is fully inserted into the reactor core. A tube piece extends from the transverse partition and is coaxially aligned to be received within a tubular receptacle which extends from the transverse wall. The tube piece and receptacle cooperate in engagement to restrict the flow and pressure of coolant beneath the transverse partition and thereby minimize upward forces tending to expel the inner conduit.

  15. A 5 MHz Cylindrical Dual-Layer Transducer Array for 3-D Transrectal Ultrasound Imaging

    PubMed Central

    Chen, Yuling; Nguyen, Man; Yen, Jesse T.

    2012-01-01

    2-D transrectal ultrasound (TRUS) is being used in guiding prostate biopsies and treatments. In many cases, the TRUS probes are moved manually or mechanically to acquire volumetric information, making the imaging slow, user-dependent and unreliable. A real-time 3-D TRUS system could improve reliability and volume rates of imaging during these procedures. In this paper, we present a 5 MHz cylindrical dual-layer transducer array capable of real-time 3-D transrectal ultrasound without any mechanically moving parts. Compared to fully-sampled 2-D arrays, this design substantially reduces the channel count and fabrication complexity. This dual-layer transducer uses PZT elements for transmit and P[VDF-TrFE] copolymer elements for receive, respectively. The mechanical flexibility of both diced PZT and copolymer makes it practical for transrectal applications. Full synthetic aperture 3-D data sets were acquired by interfacing the transducer with a Verasonics Data Acquisition System (VDAS). Offline 3-D beamforming was then performed to obtain volumes of two wire phantoms and a cyst phantom. Generalized coherence factor (GCF) was applied to improve the contrast of images. The measured −6 dB fractional bandwidth of the transducer was 62% with a center frequency of 5.66 MHz. The measured lateral beamwidths were 1.28 mm and 0.91 mm in transverse and longitudinal directions respectively, compared with a simulated beamwidth of 0.92 mm and 0.74 mm. PMID:22972914

  16. A 5-MHz cylindrical dual-layer transducer array for 3-D transrectal ultrasound imaging.

    PubMed

    Chen, Yuling; Nguyen, Man; Yen, Jesse T

    2012-07-01

    Two-dimensional transrectal ultrasound (TRUS) is being used in guiding prostate biopsies and treatments. In many cases, the TRUS probes are moved manually or mechanically to acquire volumetric information, making the imaging slow, user dependent, and unreliable. A real-time three-dimensional (3-D) TRUS system could improve reliability and volume rates of imaging during these procedures. In this article, the authors present a 5-MHz cylindrical dual-layer transducer array capable of real-time 3-D transrectal ultrasound without any mechanically moving parts. Compared with fully sampled 2-D arrays, this design substantially reduces the channel count and fabrication complexity. This dual-layer transducer uses PZT elements for transmit and P[VDF-TrFE] copolymer elements for receive, respectively. The mechanical flexibility of both diced PZT and copolymer makes it practical for transrectal applications. Full synthetic aperture 3-D data sets were acquired by interfacing the transducer with a Verasonics Data Acquisition System. Offline 3-D beamforming was then performed to obtain volumes of two wire phantoms and a cyst phantom. Generalized coherence factor was applied to improve the contrast of images. The measured -6-dB fractional bandwidth of the transducer was 62% with a center frequency of 5.66 MHz. The measured lateral beamwidths were 1.28 mm and 0.91 mm in transverse and longitudinal directions, respectively, compared with a simulated beamwidth of 0.92 mm and 0.74 mm.

  17. Transurethral ultrasound-guided laser-induced prostatectomy

    NASA Astrophysics Data System (ADS)

    Babayan, Richard K.; Roth, Robert A.

    1991-07-01

    A transurethral ultrasound-guided Nd:YAG laser delivery system has been developed for use as an alternative approach to the treatment of benign prostatic hyperplasia. The TULIP system has been extensively tested in canine models and is currently undergoing FDA trials in humans.

  18. Efficacy of ultrasound-guided percutaneous needle treatment of calcific tendinitis.

    PubMed

    Vignesh, K Nithin; McDowall, Adam; Simunovic, Nicole; Bhandari, Mohit; Choudur, Hema N

    2015-01-01

    The purpose of this study was to conduct a systematic review of the efficacy of ultrasound-guided needle lavage in treating calcific tendinitis. Two independent assessors searched medical databases and screened studies for eligibility. Eleven articles were included. Heterogeneity among included studies precluded meta-analysis. Results of randomized controlled trials suggested no difference in pain relief between needle lavage and other interventions, but the studies were of low quality. Additional high-quality evidence is required to determine the relative efficacy of ultrasound-guided needle lavage in the management of calcific tendinitis of the rotator cuff.

  19. Non-malignant breast papillary lesions - b3 diagnosed on ultrasound--guided 14-gauge needle core biopsy: analysis of 114 cases from a single institution and review of the literature.

    PubMed

    Bianchi, Simonetta; Bendinelli, Benedetta; Saladino, Valeria; Vezzosi, Vania; Brancato, Beniamino; Nori, Jacopo; Palli, Domenico

    2015-07-01

    One-hundred-fourteen consecutive cases of breast ultrasound-guided 14-gauge needle core biopsy (14G NCB) performed from January 2001 to June 2013 and diagnosed as non-malignant papillary lesion (PL)-B3, were reviewed and compared with definitive histological diagnosis on surgical excision (SE) to evaluate the diagnostic accuracy of ultrasound-guided 14G NCB. PL with epithelial atypia on 14G NCB were associated to malignancy on definitive histological diagnosis on SE in 22 (7 DCIS and 15 invasive carcinomas) of 46 cases with an underestimation rate of 47.8 %, while 9 (4 DCIS and 5 invasive carcinomas) cases out of 68 cases of PL without epithelial atypia were upgraded to carcinoma with an underestimation rate of 13.2 %. In cases of PL with epithelial atypia on ultrasound-guided 14G NCB, SE appears mandatory due to the high risk of associated malignancy. The diagnosis of PL without epithelial atypia on ultrasound-guided 14G NCB does not exclude malignancy at subsequent SE, consequently further assessment (by surgical or vacuum-assisted excision) is recommended to avoid the risk of delaying a diagnosis of malignancy, although this tends to be lower (1 in 8 patients).

  20. [Ultrasound-guided peripheral catheterization].

    PubMed

    Salleras-Duran, Laia; Fuentes-Pumarola, Concepció

    2016-01-01

    Peripheral catheterization is a technique that can be difficult in some patients. Some studies have recently described the use of ultrasound to guide the venous catheterization. To describe the success rate, time required, complications of ultrasound-guided peripheral venous catheterization. and patients and professionals satisfaction The search was performed in databases (Medline-PubMed, Cochrane Library, CINAHL and Cuiden Plus) for studies published about ultrasound-guided peripheral venous catheterization performed on patients that provided results on the success of the technique, complications, time used, patient satisfaction and the type of professional who performed the technique. A total of 21 studies were included. Most of them get a higher success rate 80% in the catheterization ecoguide and time it is not higher than the traditional technique. The Technical complications analyzed were arterial puncture rates and lower nerve 10%. In all studies measuring and comparing patient satisfaction in the art ecoguide is greater. Various professional groups perform the technique. The use of ultrasound for peripheral pipes has a high success rate, complications are rare and the time used is similar to that of the traditional technique. The technique of inserting catheters through ultrasound may be learned by any professional group performing venipuncture. Finally, it gets underscores the high patient satisfaction with the use of this technique. Copyright © 2015 Elsevier España, S.L.U. All rights reserved.

  1. American Medical Society for Sports Medicine (AMSSM) position statement: interventional musculoskeletal ultrasound in sports medicine.

    PubMed

    Finnoff, Jonathan T; Hall, Mederic M; Adams, Erik; Berkoff, David; Concoff, Andrew L; Dexter, William; Smith, Jay

    2015-02-01

    The use of diagnostic and interventional ultrasound has significantly increased over the past decade. A majority of the increased utilisation is by non-radiologists. In sports medicine, ultrasound is often used to guide interventions such as aspirations, diagnostic or therapeutic injections, tenotomies, releases and hydrodissections. Critically review the literature related to the accuracy, efficacy and cost-effectiveness of ultrasound-guided injections (USGIs) in major, intermediate and small joints; and soft tissues. Systematic review of the literature. USGIs are more accurate than landmark-guided injections (LMGIs; strength of recommendation taxonomy (SORT) Evidence Rating=A). USGIs are more efficacious than LMGIs (SORT Evidence Rating=B). USGIs are more cost-effective than LMGIs (SORT Evidence Rating=B). Ultrasound guidance is required to perform many new procedures (SORT Evidence Rating=C). The findings of this position statement indicate there is strong evidence that USGIs are more accurate than LMGI, moderate evidence that they are more efficacious and preliminary evidence that they are more cost-effective. Furthermore, ultrasound-guided (USG) is required to perform many new, advanced procedures and will likely enable the development of innovative USG surgical techniques in the future. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  2. Ultrasound-guided supraclavicular block: outcome of 510 consecutive cases.

    PubMed

    Perlas, Anahi; Lobo, Giovanni; Lo, Nick; Brull, Richard; Chan, Vincent W S; Karkhanis, Reena

    2009-01-01

    Supraclavicular brachial plexus block provides consistently effective anesthesia to the upper extremity. However, traditional nerve localization techniques may be associated with a high risk of pneumothorax. In the present study, we report block success and clinical outcome data from 510 consecutive patients who received an ultrasound-guided supraclavicular block for upper extremity surgery. After institutional review board approval, the outcome of 510 consecutive patients who received an ultrasound-guided supraclavicular block for upper extremity surgery was reviewed. Real-time ultrasound guidance was used with a high-frequency linear probe. The neurovascular structures were imaged on short axis, and the needle was inserted using an in-plane technique with either a medial-to-lateral or lateral-to-medial orientation. Five hundred ten ultrasound-guided supraclavicular blocks were performed (50 inpatients, 460 outpatients) by 47 different operators at different levels of training over a 24-month period. Successful surgical anesthesia was achieved in 94.6% of patients after a single attempt; 2.8% required local anesthetic supplementation of a single peripheral nerve territory; and 2.6% received an unplanned general anesthetic. No cases of clinically symptomatic pneumothorax developed. Complications included symptomatic hemidiaphragmatic paresis (1%), Horner syndrome (1%), unintended vascular punctures (0.4%), and transient sensory deficits (0.4%). Ultrasound-guided supraclavicular block is associated with a high rate of successful surgical anesthesia and a low rate of complications and thus may be a safe alternative for both inpatients and outpatients. Severe underlying respiratory disease and coagulopathy should remain a contraindication for this brachial plexus approach.

  3. Effects of arthroscopy-guided suprascapular nerve block combined with ultrasound-guided interscalene brachial plexus block for arthroscopic rotator cuff repair: a randomized controlled trial.

    PubMed

    Lee, Jae Jun; Hwang, Jung-Taek; Kim, Do-Young; Lee, Sang-Soo; Hwang, Sung Mi; Lee, Na Rea; Kwak, Byung-Chan

    2017-07-01

    The aim of this study was to compare the pain relieving effect of ultrasound-guided interscalene brachial plexus block (ISB) combined with arthroscopy-guided suprascapular nerve block (SSNB) with that of ultrasound-guided ISB alone within the first 48 h after arthroscopic rotator cuff repair. Forty-eight patients with rotator cuff tears who had undergone arthroscopic rotator cuff repair were enrolled. The 24 patients in group 1 received ultrasound-guided ISB and arthroscopy-guided SSNB; the remaining 24 patients in group 2 underwent ultrasound-guided ISB alone. Visual analogue scale pain score and patient satisfaction score were checked at 1, 3, 6, 12, 18, 24, and 48 h post-operatively. Group 1 had a lower visual analogue scale pain score at 3, 6, 12, 18, 24, and 48 h post-operatively (1.7 < 2.6, 1.6 < 4.0, 3.5 < 5.8, 3.6 < 5.2, 3.2 < 4.2, 1.3 < 2.0), and a higher patient satisfaction score at 6, 12, 18, 24, and 36 h post-operatively than group 2 (7.8 > 6.0, 6.2 > 4.3, 6.4 > 5.1, 6.9 > 5.9, 7.9 > 7.1). Six patients in group 1 developed rebound pain twice, and the others in group 1 developed it once. All of the patients in group 2 had one rebound phenomenon each (p = 0.010). The mean timing of rebound pain in group 1 was later than that in group 2 (15.5 > 9.3 h, p < 0.001), and the mean size of rebound pain was smaller in group 1 than that in group 2 (2.5 > 4.0, p = 0.001). Arthroscopy-guided SSNB combined with ultrasound-guided ISB resulted in lower visual analogue scale pain scores at 3-24 and 48 h post-operatively, and higher patient satisfaction scores at 6-36 h post-operatively with the attenuated rebound pain compared to scores in patients who received ultrasound-guided ISB alone after arthroscopic rotator cuff repair. The combined blocks may relieve post-operative pain more effectively than the single block within 48 h after arthroscopic cuff repair. Randomized controlled trial, Level I. ClinicalTrials.gov Identifier: NCT02424630.

  4. Design and Production of an Articulating Needle Guide for Ultrasound-Guided Needle Block Manufactured With a Three-Dimensional Printer: Technical Communication.

    PubMed

    Bigeleisen, Paul E

    2017-05-15

    Needle guides may allow the practitioner to align the needle with the probe when ultrasound-guided nerve block is performed. The author's goal was to design and fabricate an inexpensive ($1.90), disposable, needle guide that could articulate over a range from 85 degrees to 0 degrees with a three-dimension printer. Three-dimensional representations of an L50, L25, and C 60 ultrasound probe (Sono Site, Bothell, WA) were created using a laser scanner. Computer-aided design software (Solid Works, Waltham, MA) was used to design a needle bracket and needle guide to attach to these probes. A three-dimensional printer was used to fabricate the needle bracket and guide with acrylonitrile polybutadiene polystyrene. An echogenic needle was held in plane with the needle guide. The author performed a supraclavicular block in a morbidly obese patient. The needle was easily visualized. Similar guides that are commercially available cost as much as $400. A knowledge of computer-aided design is necessary for this work.

  5. [Contrast-enhanced ultrasound (CEUS) and image fusion for procedures of liver interventions].

    PubMed

    Jung, E M; Clevert, D A

    2018-06-01

    Contrast-enhanced ultrasound (CEUS) is becoming increasingly important for the detection and characterization of malignant liver lesions and allows percutaneous treatment when surgery is not possible. Contrast-enhanced ultrasound image fusion with computed tomography (CT) and magnetic resonance imaging (MRI) opens up further options for the targeted investigation of a modified tumor treatment. Ultrasound image fusion offers the potential for real-time imaging and can be combined with other cross-sectional imaging techniques as well as CEUS. With the implementation of ultrasound contrast agents and image fusion, ultrasound has been improved in the detection and characterization of liver lesions in comparison to other cross-sectional imaging techniques. In addition, this method can also be used for intervention procedures. The success rate of fusion-guided biopsies or CEUS-guided tumor ablation lies between 80 and 100% in the literature. Ultrasound-guided image fusion using CT or MRI data, in combination with CEUS, can facilitate diagnosis and therapy follow-up after liver interventions. In addition to the primary applications of image fusion in the diagnosis and treatment of liver lesions, further useful indications can be integrated into daily work. These include, for example, intraoperative and vascular applications as well applications in other organ systems.

  6. Propogation loss with frequency of ultrasound guided waves in a composite metal-honeycomb structure

    NASA Astrophysics Data System (ADS)

    Saxena, Indu F.; Baid, Harsh K.; Guzman, Narciso; Kempen, Lothar U.; Mal, Ajit

    2009-05-01

    Non-destructive testing of critical structural components is time consuming, while necessary for maintaining safe operation. Large aerospace structures, such as the vertical stabilizers of aircraft undergo inspection at regular intervals for damage diagnostics. However, conventional techniques for damage detection and identification before repair can be scheduled are conducted off-line and therefore can take weeks. The use of guided ultrasound waves is being investigated to expedite damage detection in composites. We measure the frequency dependent loss of ultrasonic guided waves for a structure comprising a boron-nitride composite skin sandwiching an aluminum honeycomb. A wide range of ultrasound frequencies propagate as measured using PZTs, with the lowest attenuation observed about 200-250 kHz. These measurements are confirmed using optical fiber Bragg grating arrays used as ultrasound transducers.

  7. Regeneration of Full-Thickness Rotator Cuff Tendon Tear After Ultrasound-Guided Injection With Umbilical Cord Blood-Derived Mesenchymal Stem Cells in a Rabbit Model.

    PubMed

    Park, Gi-Young; Kwon, Dong Rak; Lee, Sang Chul

    2015-11-01

    Rotator cuff tendon tear is one of the most common causes of chronic shoulder pain and disability. In this study, we investigated the therapeutic effects of ultrasound-guided human umbilical cord blood (UCB)-derived mesenchymal stem cell (MSC) injection to regenerate a full-thickness subscapularis tendon tear in a rabbit model by evaluating the gross morphology and histology of the injected tendon and motion analysis of the rabbit's activity. At 4 weeks after ultrasound-guided UCB-derived MSC injection, 7 of the 10 full-thickness subscapularis tendon tears were only partial-thickness tears, and 3 remained full-thickness tendon tears. The tendon tear size and walking capacity at 4 weeks after UCB-derived MSC injection under ultrasound guidance were significantly improved compared with the same parameters immediately after tendon tear. UCB-derived MSC injection under ultrasound guidance without surgical repair or bioscaffold resulted in the partial healing of full-thickness rotator cuff tendon tears in a rabbit model. Histology revealed that UCB-derived MSCs induced regeneration of rotator cuff tendon tear and that the regenerated tissue was predominantly composed of type I collagens. In this study, ultrasound-guided injection of human UCB-derived MSCs contributed to regeneration of the full-thickness rotator cuff tendon tear without surgical repair. The results demonstrate the effectiveness of local injection of MSCs into the rotator cuff tendon. The results of this study suggest that ultrasound-guided umbilical cord blood-derived mesenchymal stem cell injection may be a useful conservative treatment for full-thickness rotator cuff tendon tear repair. ©AlphaMed Press.

  8. Regeneration of Full-Thickness Rotator Cuff Tendon Tear After Ultrasound-Guided Injection With Umbilical Cord Blood-Derived Mesenchymal Stem Cells in a Rabbit Model

    PubMed Central

    Park, Gi-Young; Lee, Sang Chul

    2015-01-01

    Rotator cuff tendon tear is one of the most common causes of chronic shoulder pain and disability. In this study, we investigated the therapeutic effects of ultrasound-guided human umbilical cord blood (UCB)-derived mesenchymal stem cell (MSC) injection to regenerate a full-thickness subscapularis tendon tear in a rabbit model by evaluating the gross morphology and histology of the injected tendon and motion analysis of the rabbit’s activity. At 4 weeks after ultrasound-guided UCB-derived MSC injection, 7 of the 10 full-thickness subscapularis tendon tears were only partial-thickness tears, and 3 remained full-thickness tendon tears. The tendon tear size and walking capacity at 4 weeks after UCB-derived MSC injection under ultrasound guidance were significantly improved compared with the same parameters immediately after tendon tear. UCB-derived MSC injection under ultrasound guidance without surgical repair or bioscaffold resulted in the partial healing of full-thickness rotator cuff tendon tears in a rabbit model. Histology revealed that UCB-derived MSCs induced regeneration of rotator cuff tendon tear and that the regenerated tissue was predominantly composed of type I collagens. In this study, ultrasound-guided injection of human UCB-derived MSCs contributed to regeneration of the full-thickness rotator cuff tendon tear without surgical repair. The results demonstrate the effectiveness of local injection of MSCs into the rotator cuff tendon. Significance The results of this study suggest that ultrasound-guided umbilical cord blood-derived mesenchymal stem cell injection may be a useful conservative treatment for full-thickness rotator cuff tendon tear repair. PMID:26371340

  9. Streptococcal toxic shock syndrome after breast reconstruction.

    PubMed

    Agerson, Ashley N; Wilkins, Edwin G

    2005-05-01

    Streptococcal toxic shock syndrome (STSS) is an increasingly common disease entity but has rarely been described in the plastic surgery literature. We present the first known case of STSS associated with a reconstructive procedure. Two weeks postoperatively from a transverse rectus abdominis musculocutaneous flap for breast reconstruction, our patient presented with flulike symptoms and progressed rapidly to multiorgan failure. Though initially no nidus for infection was evident, the abdominal donor site was surgically debrided and found to contain group A Streptococcus. Following aggressive rehydration and antibiotic therapy, the patient gradually made a full recovery. In this case report, we review the presentation and epidemiology of STSS and compare it to the more common staphylococcal toxic shock syndrome. In addition, we discuss the management and outcomes of STSS, with an emphasis on raising clinical suspicion for this rare but dangerous entity.

  10. Evaluation of a simplified augmented reality device for ultrasound-guided vascular access in a vascular phantom.

    PubMed

    Jeon, Yunseok; Choi, Seungpyo; Kim, Heechan

    2014-09-01

    To investigate whether a novel ultrasound device may be used with a simplified augmented reality technique, and to compare this device with conventional techniques during vascular access using a vascular phantom. Prospective, randomized study. Anesthesiology and Pain Medicine departments of a university-affiliated hospital. 20 physicians with no experience with ultrasound-guided techniques. All participants performed the vascular access technique on the vascular phantom model using both a conventional device and the new ultrasound device. Time and the number of redirections of the needle until aspiration of dye into a vessel of the vascular phantom were measured. The median/interquartile range of time was 39.5/41.7 seconds versus 18.6/10.0 seconds (P < 0.001) and number of redirections was 3/3.5 versus 1/0 (P < 0.001) for the conventional and novel ultrasound devices, respectively. During vascular access in a vascular phantom model, the novel device decreased the time and the number of redirections significantly. The device successfully improved the efficiency of the ultrasound-guided vascular access technique. Copyright © 2014 Elsevier Inc. All rights reserved.

  11. Ultrasound-guided microwave ablation in the treatment of benign thyroid nodules in 435 patients

    PubMed Central

    Qian, Lin-Xue; Liu, Dong; Zhao, Jun-Feng

    2017-01-01

    The objective of the present study was to investigate the effectiveness and safety of ultrasound-guided microwave ablation in the treatment of benign thyroid nodules. A total of 474 benign thyroid nodules in 435 patients who underwent ultrasound-guided microwave ablation from September 2012 to August 2015 were included. Nodule volume and thyroid function were measured before treatment and at 1, 3, 6, and 12 months and subsequently after every 6 months. The nodule volume reduction rate and changes of thyroid function were evaluated. The volume of all thyroid nodules significantly decreased after ultrasound-guided microwave ablation. The average volume was 13.07 ± 0.95 ml before treatment, and 1.14 ± 0.26 ml at 12-months follow-up. The mean volume reduction rate was 90% and the final volume reduction rate was 94%. The volume reduction rate of mainly cystic nodules was significantly higher than that of simple solid and mainly solid nodules (all P < 0.05). The pretreatment volume of nodules was positively correlated with the final volume reduction rate at final follow-up (P = 0.004). No serious complications were observed after treatment. In conclusion, ultrasound-guided microwave ablation is an effective and safe technique for treatment of benign thyroid nodules, and has the potential for clinical applications. Impact statement Ultrasound-guided MWA is an effective and safe technique for the treatment of benign thyroid nodules. It can significantly reduce the nodule volume, improve the patients’ clinical symptoms, has less complication, guarantees quick recovery, meets patients' aesthetic needs, and shows less interference on the physiological and psychological aspects of the body. MWA should be a good complement to traditional open surgery and has potentials in clinical applications. PMID:28847173

  12. Ultrasound-guided microwave ablation in the treatment of benign thyroid nodules in 435 patients.

    PubMed

    Liu, Yu-Jiang; Qian, Lin-Xue; Liu, Dong; Zhao, Jun-Feng

    2017-09-01

    The objective of the present study was to investigate the effectiveness and safety of ultrasound-guided microwave ablation in the treatment of benign thyroid nodules. A total of 474 benign thyroid nodules in 435 patients who underwent ultrasound-guided microwave ablation from September 2012 to August 2015 were included. Nodule volume and thyroid function were measured before treatment and at 1, 3, 6, and 12 months and subsequently after every 6 months. The nodule volume reduction rate and changes of thyroid function were evaluated. The volume of all thyroid nodules significantly decreased after ultrasound-guided microwave ablation. The average volume was 13.07 ± 0.95 ml before treatment, and 1.14 ± 0.26 ml at 12-months follow-up. The mean volume reduction rate was 90% and the final volume reduction rate was 94%. The volume reduction rate of mainly cystic nodules was significantly higher than that of simple solid and mainly solid nodules (all P < 0.05). The pretreatment volume of nodules was positively correlated with the final volume reduction rate at final follow-up ( P = 0.004). No serious complications were observed after treatment. In conclusion, ultrasound-guided microwave ablation is an effective and safe technique for treatment of benign thyroid nodules, and has the potential for clinical applications. Impact statement Ultrasound-guided MWA is an effective and safe technique for the treatment of benign thyroid nodules. It can significantly reduce the nodule volume, improve the patients' clinical symptoms, has less complication, guarantees quick recovery, meets patients' aesthetic needs, and shows less interference on the physiological and psychological aspects of the body. MWA should be a good complement to traditional open surgery and has potentials in clinical applications.

  13. Ultrasound-guided synovial Tru-cut biopsy: indications, technique, and outcome in 111 cases.

    PubMed

    Sitt, Jacqueline C M; Griffith, James F; Lai, Fernand M; Hui, Mamie; Chiu, K H; Lee, Ryan K L; Ng, Alex W H; Leung, Jason

    2017-05-01

    To investigate the diagnostic performance of ultrasound-guided synovial biopsy. Clinical notes, pathology and microbiology reports, ultrasound and other imaging studies of 100 patients who underwent 111 ultrasound-guided synovial biopsies were reviewed. Biopsies were compared with the final clinical diagnosis established after synovectomy (n = 43) or clinical/imaging follow-up (n = 57) (mean 30 months). Other than a single vasovagal episode, no complication of synovial biopsy was encountered. One hundred and seven (96 %) of the 111 biopsies yielded synovium histologically. Pathology ± microbiology findings for these 107 conclusive biopsies comprised synovial tumour (n = 30, 28 %), synovial infection (n = 18, 17 %), synovial inflammation (n = 45, 42 %), including gouty arthritis (n = 3), and no abnormality (n = 14, 13 %). The accuracy, sensitivity, and specificity of synovial biopsy was 99 %, 97 %, and 100 % for synovial tumour; 100 %, 100 %, and 100 % for native joint infection; and 78 %, 45 %, and 100 % for prosthetic joint infection. False-negative synovial biopsy did not seem to be related to antibiotic therapy. Ultrasound-guided Tru-cut synovial biopsy is a safe and reliable technique with a high diagnostic yield for diagnosing synovial tumour and also, most likely, for joint infection. Regarding joint infection, synovial biopsy of native joints seems to have a higher diagnostic yield than that for infected prosthetic joints. • Ultrasound-guided Tru-cut synovial biopsy has high accuracy (99 %) for diagnosing synovial tumour. • It has good accuracy, sensitivity, and high specificity for diagnosis of joint infection. • Synovial biopsy of native joints works better than biopsy of prosthetic joints. • A negative synovial biopsy culture from a native joint largely excludes septic arthritis. • Ultrasound-guided Tru-cut synovial biopsy is a safe and well-tolerated procedure.

  14. The effects of running in place in a limited area with abdominal drawing-in maneuvers on abdominal muscle thickness in chronic low back pain patients.

    PubMed

    Gong, Wontae

    2016-11-21

    Based on previous studies indicating that core stabilization exercises accompanied by abdominal drawing-in maneuvers increase the thickness of the transversus abdominis muscle. The purpose of this study was to compare the measurements of abdominal muscle thicknesses during running in place in a limited area with the abdominal drawing-in maneuver. The study classified the subjects into two experimental groups: the training group (M = 2, F = 13), and the control group (M = 2, F = 13). The training group performed three sets of running in place in a limited area with abdominal drawing-in maneuvers each time, three times a week for six weeks. The abdominal muscle thicknesses of the subjects were measured using ultrasonography. Comparing the training group's abdominal muscle thickness before and after this study, there was a statistical significance in all of the external obliquus abdominis, the internal obliquus abdominis, and the transversus abdominis. In particular, thicknesses of external obliquus abdominis and internal obliquus increased remarkably. Running in place in a limited area accompanied by abdominal drawing-in maneuvers increased the thickness of the deep abdominal muscles that are the basis of trunk stabilization.

  15. Dynamic rectus abdominis muscle sphincter for stoma continence: an acute functional study in a dog model.

    PubMed

    Bardoel, J W; Stadelmann, W K; Perez-Abadia, G A; Galandiuk, S; Zonnevijlle, E D; Maldonado, C; Stremel, R W; Tobin, G R; Kon, M; Barker, J H

    2001-02-01

    Fecal stomal incontinence is a problem that continues to defy surgical treatment. Previous attempts to create continent stomas using dynamic myoplasty have had limited success due to denervation atrophy of the muscle flap used in the creation of the sphincter and because of muscle fatigue resulting from continuous electrical stimulation. To address the problem of denervation atrophy, a stomal sphincter was designed using the most caudal segment of the rectus abdominis muscle, preserving its intercostal innervation as well as its vascular supply. The purpose of the present study was to determine whether this rectus abdominis muscle island flap sphincter design could maintain stomal continence acutely. In this experiment, six dogs were used to create eight rectus abdominis island flap stoma sphincters around a segment of distal ileum. Initially, the intraluminal stomal pressures generated by the sphincter using different stimulation frequencies were determined. The ability of this stomal sphincter to generate continence at different intraluminal bowel pressures was then assessed. In all cases, the rectus abdominis muscle sphincter generated peak pressures well above those needed to maintain stomal continence (60 mmHg). In addition, each sphincter was able to maintain stomal continence at all intraluminal bowel pressures tested.

  16. A comparison of plasma levobupivacaine concentrations following transversus abdominis plane block and rectus sheath block.

    PubMed

    Yasumura, R; Kobayashi, Y; Ochiai, R

    2016-05-01

    Levobupivacaine is commonly used as the local anaesthetic of choice in peripheral nerve blocks, but its pharmacokinetics have not been fully investigated. We compared the changes in plasma concentrations of levobupivacaine following transversus abdominis plane block and rectus sheath block. Fifty woman undergoing laparoscopy were randomly allocated to receive either a transversus abdominis plane block or an rectus sheath block. In both groups, 2.5 mg.kg(-1) levobupivacaine was administered, and blood samples were obtained 15 min, 30 min, 60 min and 120 min after injection. The mean maximum plasma concentration (Cmax) and mean time to reach Cmax (Tmax) as determined by non-linear regression analysis were 1.05 μg.ml(-1) and 32.4 min in the transversus abdominis plane group and 0.95 μg.ml(-1) and 60.9 min in the rectus sheath group, respectively. The plasma concentration of levobupivacaine peaked earlier in the transversus abdominis plane group than in the rectus sheath group and the maximum plasma concentration depended on the dose administered but not the procedure. © 2016 The Association of Anaesthetists of Great Britain and Ireland.

  17. 3D ultrasound imaging in image-guided intervention.

    PubMed

    Fenster, Aaron; Bax, Jeff; Neshat, Hamid; Cool, Derek; Kakani, Nirmal; Romagnoli, Cesare

    2014-01-01

    Ultrasound imaging is used extensively in diagnosis and image-guidance for interventions of human diseases. However, conventional 2D ultrasound suffers from limitations since it can only provide 2D images of 3-dimensional structures in the body. Thus, measurement of organ size is variable, and guidance of interventions is limited, as the physician is required to mentally reconstruct the 3-dimensional anatomy using 2D views. Over the past 20 years, a number of 3-dimensional ultrasound imaging approaches have been developed. We have developed an approach that is based on a mechanical mechanism to move any conventional ultrasound transducer while 2D images are collected rapidly and reconstructed into a 3D image. In this presentation, 3D ultrasound imaging approaches will be described for use in image-guided interventions.

  18. A Randomized Double-Blinded Trial on the Effects of Ultrasound Transducer Orientation on Teaching and Learning Ultrasound-Guided Regional Anesthesia.

    PubMed

    Lam, Nicholas C K; Baker, Elizabeth B; Fishburn, Steven J; Hammer, Angie R; Petersen, Timothy R; Mariano, Edward R

    2016-07-01

    Learning ultrasound-guided regional anesthesia skills, especially needle/ beam alignment, can be especially difficulty for trainees, who can often become frustrated. We hypothesized that teaching novices to orient the transducer and needle perpendicular to their shoulders will improve performance on a standardized task, compared to holding the transducer and needle parallel to the shoulders. This study compared the effects of transducer orientation on trainees' ability to complete a standardized ultrasound-guided nerve block simulation. The time to task completion and percentage of the attempt time without adequate needle visualization were measured. Participants were right-handed healthy adults with no previous ultrasound experience and were randomly assigned to training in either transducer and needle alignment in a coronal plane, parallel to the shoulders (parallel group) or transducer and needle alignment in a sagittal plane, perpendicular to the shoulders (perpendicular group). Participants used ultrasound to direct a needle to 3 targets in a standardized gelatin phantom and repeated this task 3 times. Their efforts were timed and evaluated by an assessor, who was blinded to group assignment. Data were analyzed on 28 participants. The perpendicular group was able to complete the task more quickly (P < .001) and with a smaller proportion of time lost to inadequate needle visualization (P < .001). Ultrasound-guided regional anesthesia trainees complete a standardized task more quickly and efficiently when instructed to hold the transducer and needle in an orientation perpendicular to their shoulders.

  19. [An easy, safe and affective method for the treatment of intussusception: ultrasound-guided hydrostatic reduction].

    PubMed

    Ülger, Fatma Esra Bahadır; Ülger, Aykut; Karakaya, Ali Erdal; Tüten, Fatih; Katı, Ömer; Çolak, Mustafa

    2014-03-01

    Intussusception is one of the important causes of intestinal obstruction in children. Hydrostatic reduction under ultrasound guidance is a popular treatment method for intussusception. In the present study, we aimed to explain the demographic characteristics of and treatment approaches in patients diagnosed with intussusception by ultrasound. Forty-one patients diagnosed with intussusception by ultrasound between August 2011 and May 2013 were retrospectively analyzed. Twenty-four of these patients who had no contraindications had been treated with ultrasound-guided hydrostatic reduction. Twenty-four of the patients were male and 17 were female, a 1.4/1 male-to-female ratio. The majority of the patients were between the ages of 6-24 months and 2-5 years. The mean age was 31.12±26.32 months (range 3-125). Patients were more frequently diagnosed in April and May. Seventeen patients who had clinical contraindications enrolled directly for surgery. In 20 of the 24 patients who underwent ultrasound-guided hydrostatic reduction, reduction was achieved. Three experienced recurrence. In two of these patients, successful reduction was achieved with the second attempt. The remaining patient was enrolled for surgery. Hydrostatic reduction was performed 26 times on these 24 patients, and in 22, success was achieved (84.6%). No procedure-related complications occurred in the patients. Ultrasound-guided hydrostatic reduction, with its high success rates and lack of radiation risk, should be the first choice therapeutic approach for children diagnosed with intussusception.

  20. Pregnancies following ultrasound-guided drainage of tubo-ovarian abscess.

    PubMed

    Gjelland, Knut; Granberg, Seth; Kiserud, Torvid; Wentzel-Larsen, Tore; Ekerhovd, Erling

    2012-07-01

    To study fertility among women treated by means of ultrasound-guided drainage and antibiotics for tubo-ovarian abscess (TOA). Retrospective cohort study. A tertiary referral center. One hundred women of reproductive age treated for TOA between June 1986 and July 2003. Transvaginal ultrasound-guided drainage of TOA was performed in all patients. The procedure was repeated if a substantial amount of pus was seen using ultrasonography 2-5 days after the initial aspiration, and repeated later if necessary. Frequency of naturally conceived pregnancies. Twenty of 38 (52.6%; 95% CI 36.5-68.9%) women who intended to have a child achieved pregnancy naturally and became mothers. In addition, 7 (50%) of 14 women who were not on birth control on a regular basis became pregnant. No ectopic pregnancies were registered. Ultrasound-guided drainage of TOA in combination with antibiotics seems to preserve fertility in approximately half of the patients. Copyright © 2012 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  1. Effectiveness of ultrasound-guided injections combined with shoulder exercises in the treatment of subacromial adhesive bursitis.

    PubMed

    Gasparre, Giuseppe; Fusaro, Isabella; Galletti, Stefano; Volini, Silvia; Benedetti, Maria Grazia

    2012-05-01

    The aim of this study was to evaluate whether the association of exercises for the shoulder with ultrasound-guided injection into the bursa significantly improves the treatment outcome in adhesive bursitis. Two groups of 35 patients, one treated with ultrasound-guided injection (UGI) and the other one with ultrasound-guided injection and home exercise program (UGI-exercise) for 1 month, were assessed for pain and shoulder function before treatment, 1 and 3 months post-treatment. Fourteen patients in UGI group and 23 patients in the UGI-exercises group were completely free of pain after 1 month (p = 0.031). At 3 months' follow-up, patients in the UGI-exercise group showed a significant improvement with respect to the other group (p = 0.005). No differences were found in function assessment. The UGI combined with shoulder exercises in the treatment of subacromial adhesive bursitis is effective to ensure a more frequent complete pain relief in the medium term.

  2. B-Mode ultrasound pose recovery via surgical fiducial segmentation and tracking

    NASA Astrophysics Data System (ADS)

    Asoni, Alessandro; Ketcha, Michael; Kuo, Nathanael; Chen, Lei; Boctor, Emad; Coon, Devin; Prince, Jerry L.

    2015-03-01

    Ultrasound Doppler imaging may be used to detect blood clots after surgery, a common problem. However, this requires consistent probe positioning over multiple time instances and therefore significant sonographic expertise. Analysis of ultrasound B-mode images of a fiducial implanted at the surgical site offers a landmark to guide a user to the same location repeatedly. We demonstrate that such an implanted fiducial may be successfully detected and tracked to calculate pose and guide a clinician consistently to the site of surgery, potentially reducing the ultrasound experience required for point of care monitoring.

  3. Molecular Endoscopic Ultrasound for Diagnosis of Pancreatic Cancer

    PubMed Central

    Bournet, Barbara; Pointreau, Adeline; Delpu, Yannick; Selves, Janick; Torrisani, Jerome; Buscail, Louis; Cordelier, Pierre

    2011-01-01

    Endoscopic ultrasound-guided fine needle aspiration-biopsy is a safe and effective technique in diagnosing and staging of pancreatic ductal adenocarcinoma. However its predictive negative value does not exceed 50% to 60%. Unfortunately, the majority of pancreatic cancer patients have a metastatic and/or a locally advanced disease (i.e., not eligible for curative resection) which explains the limited access to pancreatic tissue specimens. Endoscopic ultrasound-guided fine needle aspiration-biopsy is the most widely used approach for cytological and histological material sampling in these situations used in up to two thirds of patients with pancreatic cancer. Based on this unique material, we and others developed strategies to improve the differential diagnosis between carcinoma and inflammatory pancreatic lesions by analysis of KRAS oncogene mutation, microRNA expression and methylation, as well as mRNA expression using both qRT-PCR and Low Density Array Taqman analysis. Indeed, differentiating pancreatic cancer from pseudotumoral chronic pancreatitis remains very difficult in current clinical practice, and endoscopic ultrasound-guided fine needle aspiration-biopsy analysis proved to be very helpful. In this review, we will compile the clinical and molecular advantages of using endoscopic ultrasound-guided fine needle aspiration-biopsy in managing pancreatic cancer. PMID:24212643

  4. Teaching medical students ultrasound-guided vascular access - which learning method is best?

    PubMed

    Lian, Alwin; Rippey, James C R; Carr, Peter J

    2017-05-15

    Ultrasound is recommended to guide insertion of peripheral intravenous vascular cannulae (PIVC) where difficulty is experienced. Ultrasound machines are now common-place and junior doctors are often expected to be able to use them. The educational standards for this skill are highly varied, ranging from no education, to self-guided internet-based education, to formal, face-to-face traditional education. In an attempt to decide which educational technique our institution should introduce, a small pilot trial comparing educational techniques was designed. Thirty medical students were enrolled and allocated to one of three groups. PIVC placing ability was then observed, tested and graded on vascular access phantoms. The formal, face-to-face traditional education was rated best by the students, and had the highest success rate in PIVC placement, the improvement statistically significant compared to no education (p = 0.01) and trending towards significance when compared to self-directed internet-based education (p<0.06). The group receiving traditional face-to-face teaching on ultrasound-guided vascular access, performed significantly better than those not receiving education. As the number of ultrasound machines in clinical areas increases, it is important that education programs to support their safe and appropriate use are developed.

  5. Comparison of a GPS needle-tracking system, multiplanar imaging and 2D imaging for real-time ultrasound-guided epidural anaesthesia: A randomized, comparative, observer-blinded study on phantoms.

    PubMed

    Menacé, Cécilia; Choquet, Olivier; Abbal, Bertrand; Bringuier, Sophie; Capdevila, Xavier

    2017-04-01

    The real-time ultrasound-guided paramedian sagittal oblique approach for neuraxial blockade is technically demanding. Innovative technologies have been developed to improve nerve identification and the accuracy of needle placement. The aim of this study was to evaluate three types of ultrasound scans during ultrasound-guided epidural lumbar punctures in a spine phantom. Eleven sets of 20 ultrasound-guided epidural punctures were performed with 2D, GPS, and multiplanar ultrasound machines (660 punctures) on a spine phantom using an in-plane approach. For all punctures, execution time, number of attempts, bone contacts, and needle redirections were noted by an independent physician. Operator comfort and visibility of the needle (tip and shaft) were measured using a numerical scale. The use of GPS significantly decreased the number of punctures, needle repositionings, and bone contacts. Comfort of the physician was also significantly improved with the GPS system compared with the 2D and multiplanar systems. With the multiplanar system, the procedure was not facilitated and execution time was longer compared with 2D imaging after Bonferroni correction but interaction between the type of ultrasound system and mean execution time was not significant in a linear mixed model. There were no significant differences regarding needle tip and shaft visibility between the systems. Multiplanar and GPS needle-tracking systems do not reduce execution time compared with 2D imaging using a real-time ultrasound-guided paramedian sagittal oblique approach in spine phantoms. The GPS needle-tracking system can improve performance in terms of operator comfort, the number of attempts, needle redirections and bone contacts. Copyright © 2016 Société française d'anesthésie et de réanimation (Sfar). Published by Elsevier Masson SAS. All rights reserved.

  6. Colostomy with Transversus Abdominis Plane Block

    PubMed Central

    Tekelioğlu, Ümit Yaşar; Demirhan, Abdullah; Şit, Mustafa; Kurt, Adem Deniz; Bilgi, Murat; Koçoğlu, Hasan

    2015-01-01

    Transversus abdominis plane (TAP) block is one of the abdominal field block. The TAP block is used for both anaesthetic management and post-operative pain therapy in lower abdominal surgery. TAP block is a procedure in which local anaesthetic agents are applied to the anatomic neurofacial space between the internal oblique and the transversus abdominis muscle. TAP block is a good method for post-operative pain control as well as allows for short operations involving the abdominal area. In this article, a case of colostomy under TAP block is presented. PMID:27366540

  7. Evaluating the functional outcomes of ultrasound-guided botulinum toxin type A injections using the Euro-musculus approach for upper limb spasticity treatment in post-stroke patients; an observational study.

    PubMed

    Buyukavci, Raikan; Akturk, Semra; Ersoy, Yüksel

    2018-02-07

    Ultrasound-guided botulinum toxin type A injection is an effective treatment for spasticity. Euro-musculus spasticity approach is a new method for administering injections to the correct point of the correct muscle. The clinical outcomes of this practical approach is not yet available in the literature. The purpose of this study was to evaluate the effects on spasticity and the functional outcomes of ultrasound guided botulinum toxin type A injections via the Euro-musculus spasticity approach to treat upper limb spasticity in post-stroke patients. An observational study. Inpatient post-stroke patients. Twenty five post-stroke patients with post-stroke upper limb spasticity were recruited. The ultrasound-guided botulinum toxin type A injections were administered into the spastic target muscles using the Euro-musculus spasticity approach, and all of the patients were enrolled in rehabilitation programmes after the injections. This research included the innervation zone and injection site figures and ultrasound images of each muscle in the upper limb. The degree of spasticity was assessed via the Modified Ashworth Scale and the upper limb motor function via the Fugl Meyer Upper Extremity Scale at the baseline and 4 and 12 weeks after the botulinum toxin type A injection. Significant decreases in the Modified Ashworth Scale scores of the upper limb flexor muscle tone measured 4 and 12 weeks after the botulinum toxin type A injection were found when compared to the baseline scores (p<0.025). When compared with the baseline Fugl Meyer Upper Extremity subgroup scores, the sitting position, wrist and total scores at 4 and 12 weeks were significantly improved (p<0.025). However, only the Fugl Meyer Upper Extremity hand scores were significantly improved 12 weeks after the injection (p<0.025). Ultrasound-guided botulinum toxin type A injection via the Euro- musculus spasticity approach is a practical and effective method for administering injections to the correct point of the correct muscle. Ultrasound-guided botulinum toxin type A injections combined with rehabilitation programmes decrease spasticity and improve the upper extremity motor functions in stroke patients. This new approach for ultrasound- guided botulinum toxin type A injection is very practical and effective method for upper extremity spasticity.

  8. Ultrasound Guidance and Monitoring of Laser-Based Fat Removal

    PubMed Central

    Shah, Jignesh; Thomsen, Sharon; Milner, Thomas E.; Emelianov, Stanislav Y.

    2009-01-01

    Background and Objectives We report on a study to investigate feasibility of utilizing ultrasound imaging to guide laser removal of subcutaneous fat. Ultrasound imaging can be used to identify the tissue composition and to monitor the temperature increase in response to laser irradiation. Study Design/Materials and Methods Laser heating was performed on ex vivo porcine subcutaneous fat through the overlying skin using a continuous wave laser operating at 1,210 nm optical wavelength. Ultrasound images were recorded using a 10 MHz linear array-based ultrasound imaging system. Results Ultrasound imaging was utilized to differentiate between water-based and lipid-based regions within the porcine tissue and to identify the dermis-fat junction. Temperature maps during the laser exposure in the skin and fatty tissue layers were computed. Conclusions Results of our study demonstrate the potential of using ultrasound imaging to guide laser fat removal. PMID:19065554

  9. [Percutaneous renal puncture guide by a novel real-time needle-tracking ultrasound system for percutaneous nephrolithotomy: analysis of 16 cases].

    PubMed

    Ma, Kai; Huang, Xiao-bo; Xiong, Liu-lin; Xu, Qing-quan; Xu, Tao; Ye, Hai-yun; Yu, Lu-ping; Wang, Xiao-feng

    2014-08-18

    To evaluate the feasibility and efficacy of percutaneous renal puncture in percutaneous nephrolithotomy guided by novel needle-tracking ultrasound system. From may to october 2013, 16 cases of percutaneous nephrolithotomy were performed under the guidance of ultrasound system. The clinical data including the time of completing percutaneous renal puncture, the color of urine sucked out from the kidney calices, and the complications were analyzed retrospectively. Of the 16 patients, 18 percutaneous renal access were established guided by ultrasound system. All of them were successtul for the first time, and the average time of completing percutaneous renal punctures was (26.90 ± 11.37) s (15 to 54 s). After the operation, the hemoglobin decreased by (9.56 ± 5.27)%(1.41% to 24.06%), and no complications occurred except for postoperative fever in 2 case. The novel ultrasound system is a safe and effective technique that can reduce the technical difficulty of percutaneous renal puncture in percutaneous nephrolithotomy.

  10. Anaesthetics, steroids and platelet-rich plasma (PRP) in ultrasound-guided musculoskeletal procedures

    PubMed Central

    La Marra, Alice; Arrigoni, Francesco; Mariani, Silvia; Zugaro, Luigi; Splendiani, Alessandra; Di Cesare, Ernesto; Reginelli, Alfonso; Zappia, Marcello; Brunese, Luca; Duka, Ejona; Carrafiello, Giampaolo; Masciocchi, Carlo

    2016-01-01

    This review aims to evaluate the role of anaesthetics, steroids and platelet-rich plasma (PRP) employed with ultrasound-guided injection in the management of musculoskeletal pathology of the extremities. Ultrasound-guided injection represents an interesting and minimally invasive solution for the treatment of tendon and joint inflammatory or degenerative diseases. The availability of a variety of new drugs such as hyaluronic acid and PRP provides expansion of the indications and therapeutic possibilities. The clinical results obtained in terms of pain reduction and functional recovery suggest that the use of infiltrative procedures can be a good therapeutic alternative in degenerative and inflammatory joint diseases. PMID:27302491

  11. Anaesthetics, steroids and platelet-rich plasma (PRP) in ultrasound-guided musculoskeletal procedures.

    PubMed

    Barile, Antonio; La Marra, Alice; Arrigoni, Francesco; Mariani, Silvia; Zugaro, Luigi; Splendiani, Alessandra; Di Cesare, Ernesto; Reginelli, Alfonso; Zappia, Marcello; Brunese, Luca; Duka, Ejona; Carrafiello, Giampaolo; Masciocchi, Carlo

    2016-09-01

    This review aims to evaluate the role of anaesthetics, steroids and platelet-rich plasma (PRP) employed with ultrasound-guided injection in the management of musculoskeletal pathology of the extremities. Ultrasound-guided injection represents an interesting and minimally invasive solution for the treatment of tendon and joint inflammatory or degenerative diseases. The availability of a variety of new drugs such as hyaluronic acid and PRP provides expansion of the indications and therapeutic possibilities. The clinical results obtained in terms of pain reduction and functional recovery suggest that the use of infiltrative procedures can be a good therapeutic alternative in degenerative and inflammatory joint diseases.

  12. Investigation for all polarization conversions of the guided-modes in a bending waveguide

    NASA Astrophysics Data System (ADS)

    Shi, Yunjie; Shang, Hongpeng; Sun, DeGui

    2018-03-01

    In this work, a new solution to the partial differential Maxwell equations is first derived to investigate all polarization conversions of the transverse and the longitudinal components of guided-modes in a bending waveguide. Then, for the silica-waveguides, the polarization conversion efficiencies are numerical calculated and a significant finding is that the transverse-longitudinal polarization conversion efficiency is much higher than that of transverse-transverse polarization conversion. Furthermore, the dependences of all the conversion efficiencies on waveguide parameters are found. The agreeable results between the numerical calculation and the finite difference time-domain (FDTD) simulation show that for two 100 μm long bending waveguides of 0.75 and 1.50% index contrasts, the amplitude conversion efficiencies from ∼10-3 to ∼10-2 can be realized for the transverse-transverse polarization components and that of ∼10-1 can be realized for the transverse-longitudinal polarization components.

  13. In-line positioning of ultrasound images using wireless remote display system with tablet computer facilitates ultrasound-guided radial artery catheterization.

    PubMed

    Tsuchiya, Masahiko; Mizutani, Koh; Funai, Yusuke; Nakamoto, Tatsuo

    2016-02-01

    Ultrasound-guided procedures may be easier to perform when the operator's eye axis, needle puncture site, and ultrasound image display form a straight line in the puncture direction. However, such methods have not been well tested in clinical settings because that arrangement is often impossible due to limited space in the operating room. We developed a wireless remote display system for ultrasound devices using a tablet computer (iPad Mini), which allows easy display of images at nearly any location chosen by the operator. We hypothesized that the in-line layout of ultrasound images provided by this system would allow for secure and quick catheterization of the radial artery. We enrolled first-year medical interns (n = 20) who had no prior experience with ultrasound-guided radial artery catheterization to perform that using a short-axis out-of-plane approach with two different methods. With the conventional method, only the ultrasound machine placed at the side of the head of the patient across the targeted forearm was utilized. With the tablet method, the ultrasound images were displayed on an iPad Mini positioned on the arm in alignment with the operator's eye axis and needle puncture direction. The success rate and time required for catheterization were compared between the two methods. Success rate was significantly higher (100 vs. 70 %, P = 0.02) and catheterization time significantly shorter (28.5 ± 7.5 vs. 68.2 ± 14.3 s, P < 0.001) with the tablet method as compared to the conventional method. An ergonomic straight arrangement of the image display is crucial for successful and quick completion of ultrasound-guided arterial catheterization. The present remote display system is a practical method for providing such an arrangement.

  14. Comparison of Stereotactic and Ultrasound-guided Biopsy of Solid Supratentorial Tumor: A Preliminary Report

    PubMed Central

    Satyarthee, Guru Dutta; Chandra, P. Sarat; Sharma, Bhawani S.; Mehta, V. S.

    2017-01-01

    Introduction: The computed tomography (CT) guided stereotactic biopsy (STB) is considered as method of choice for biopsy of intracranial mass lesions. However, it's disadvantages are frame fixation, time requirement for transportation between CT scan suit to the operation theater with added much higher equipment cost in the relatively resource scarred developing country. Ultrasound-guided biopsy (USGB) is relatively simpler, economical, less time consuming, and real-time procedure. Clinical Materials and Methods: Thirty-seven consecutively admitted patients with supratentorial brain tumors, who underwent biopsy of the lesion using CT compatible stereotactic and ultrasound-guided (USGB) procedure formed cohort of the study. Based on location and size of the lesions, the cases were divided into two groups, superficial and deep. Twenty-two patients underwent ultrasound-guided biopsy and 15 with STB. Results: The diagnostic yield of STB was 93% and 91% for ultrasound-guided biopsy. The mean operation time of STB group was 149.00 min and 94 min for USGB, which was statistically significant. Two cases in each group developed hematoma; however, one case in USGB group needed surgical evacuation. The real-time monitoring detected two hematoma intraoperatively, which were further also confirmed on postoperative CT scan head. Conclusions: The ultrasound-guided biopsy procedure (USGB) was simple, relatively shorter time-consuming procedure and equally efficacious and utilizing economical equipment and can act as a safer alternative to CT STB process for biopsy of the intracranial mass lesion. Furthermore, USGB also provided intra-operative real-time monitoring, which provided clue for close monitoring in the postoperative period after completion of biopsy to look for development of fresh hematoma development not only at the biopsy site but also along the biopsy track and adjoining area. Perhaps, a longer period of ultrasonic monitoring following the procedure would be of greater help to detect hematoma formation, which is one of the most common complications of the biopsy procedure. PMID:29114280

  15. Use of Lymph Node Ultrasound Prior to Sentinel Lymph Node Biopsy in 384 Patients with Melanoma: A Cost-Effectiveness Analysis.

    PubMed

    Olmedo, D; Brotons-Seguí, M; Del Toro, C; González, M; Requena, C; Traves, V; Pla, A; Bolumar, I; Moreno-Ramírez, D; Nagore, E

    2017-12-01

    Locoregional lymph node ultrasound is not typically included in guidelines as part of the staging process prior to sentinel lymph node biopsy (SLNB). The objective of the present study was to make a clinical and economic analysis of lymph node ultrasound prior to SLNB. We performed a retrospective study of 384 patients with clinical stage I-II primary melanoma who underwent locorregional lymph node ultrasound (with or without ultrasound-guided biopsy) prior to SLNB between 2004 and 2015. We evaluated the reliability and cost-effectiveness of the strategy. Use of locorregional lymph node ultrasound avoided SLNB in 23 patients (6%). Ultrasound had a sensitivity of 46% and specificity of 76% for the detection of metastatic lymph nodes that were not clinically palpable. False negatives were significantly more common in patients aged over 60 years and in tumors with a thickness of less than 2mm. The staging process using SLNB and ultrasound with ultrasound-guided biopsy produced an increase of €16.30 in the unit price. Our cost-effectiveness analysis identified the staging protocol with ultrasound and SLNB as the dominant strategy, with a lower cost-effectiveness ratio than the alternative, consisting of SLNB alone (8,095.24 vs. €28,605.00). Ultrasound with ultrasound-guided biopsy for the diagnostic staging of melanoma prior to SLNB is a useful and cost-effective tool. This procedure does not substitute SLNB, though it does allow to avoid SLNB in a not insignificant proportion of patients. Copyright © 2017 AEDV. Publicado por Elsevier España, S.L.U. All rights reserved.

  16. Effects of neuromuscular joint facilitation on bridging exercises with respect to deep muscle changes.

    PubMed

    Zhou, Bin; Huang, QiuChen; Zheng, Tao; Huo, Ming; Maruyama, Hitoshi

    2015-05-01

    [Purpose] This study examined the effects of neuromuscular joint facilitation on bridging exercises by assessing the cross-sectional area of the multifidus muscle and thickness of the musculus transversus abdominis. [Subjects] Twelve healthy men. [Methods] Four exercises were evaluated: (a) supine resting, (b) bridging resistance exercise involving posterior pelvic tilting, (c) bridging resistance exercise involving anterior pelvic tilting, and (d) bridging resistance exercise involving neuromuscular joint facilitation. The cross-sectional area of the multifidus muscle and thickness of the musculus transversus abdominis were measured during each exercise. [Results] The cross-sectional area of the multifidus muscle and thickness of the musculus transversus abdominis were significantly greater in the neuromuscular joint facilitation group than the others. [Conclusion] Neuromuscular joint facilitation intervention improves the function of deep muscles such as the multifidus muscle and musculus transversus abdominis. Therefore, it can be recommended for application in clinical treatments such as that for back pain.

  17. Blunt transection of rectus abdominis following seatbelt related trauma with associated small and large bowel injury.

    PubMed

    Patel, K; Doolin, R; Suggett, N

    2013-01-01

    Closed rupture of rectus abdominis following seatbelt related trauma is rare. We present the case of a 45 year old female who presented with closed rupture of the rectus abdominis in conjunction with damage to small bowel mesentery and infarction of small and large bowel following a high velocity road traffic accident. Multiple intestinal resections were required resulting in short bowel syndrome and abdominal wall reconstruction with a porcine collagen mesh. Post-operative complications included intra-abdominal sepsis and an enterocutaneous fistula. The presence of rupture of rectus abdominis muscle secondary to seatbelt injury should raise the suspicion of intra-abdominal injury. Our case highlights the need for suspicion, investigation and subsequent surgical management of intra-abdominal injury following identification of this rare consequence of seatbelt trauma. Copyright © 2013 The Authors. Published by Elsevier Ltd.. All rights reserved.

  18. Real-time computed tomography dosimetry during ultrasound-guided brachytherapy for prostate cancer.

    PubMed

    Kaplan, Irving D; Meskell, Paul; Oldenburg, Nicklas E; Saltzman, Brian; Kearney, Gary P; Holupka, Edward J

    2006-01-01

    Ultrasound-guided implantation of permanent radioactive seeds is a treatment option for localized prostate cancer. Several techniques have been described for the optimal placement of the seeds in the prostate during this procedure. Postimplantation dosimetric calculations are performed after the implant. Areas of underdosing can only be corrected with either an external beam boost or by performing a second implant. We demonstrate the feasibility of performing computed tomography (CT)-based postplanning during the ultrasound-guided implant and subsequently correcting for underdosed areas. Ultrasound-guided brachytherapy is performed on a modified CT table with general anesthesia. The postplanning CT scan is performed after the implant, while the patient is still under anesthesia. Additional seeds are implanted into "cold spots," and the resultant dosimetry confirmed with CT. Intraoperative postplanning was successfully performed. Dose-volume histograms demonstrated adequate dose coverage during the initial implant, but on detailed analysis, for some patients, areas of underdosing were observed either at the apex or the peripheral zone. Additional seeds were implanted to bring these areas to prescription dose. Intraoperative postplanning is feasible during ultrasound-guided brachytherapy for prostate cancer. Although the postimplant dose-volume histograms for all patients, before the implantation of additional seeds, were adequate according to the American Brachytherapy Society criteria, specific critical areas can be underdosed. Additional seeds can then be implanted to optimize the dosimetry and reduce the risk of underdosing areas of cancer.

  19. Guided Interventions for Prostate Cancer Using 3D-Transurethral Ultrasound and MRI Fusion

    DTIC Science & Technology

    2017-06-01

    standard transrectal ultrasound (TRUS) probe, a TUUS probe, and MRI. (a) (b) Figure 2: 3D printed prostate phantom mold (a), and pelvis phantom mold...with prostate agar phantom in place (b). The TUUS phantoms were prepared using a standard recipe [ii] for the prostate and the 3D printed mold...AWARD NUMBER: W81XWH-14-1-0461 TITLE: Guided Interventions for Prostate Cancer Using 3D -Transurethral Ultrasound and MRI Fusion PRINCIPAL

  20. The American Society of Regional Anesthesia and Pain Medicine, the European Society of Regional Anaesthesia and Pain Therapy, and the Asian Australasian Federation of Pain Societies Joint Committee recommendations for education and training in ultrasound-guided interventional pain procedures.

    PubMed

    Narouze, Samer N; Provenzano, David; Peng, Philip; Eichenberger, Urs; Lee, Sang Chul; Nicholls, Barry; Moriggl, Bernhard

    2012-01-01

    The use of ultrasound in pain medicine for interventional axial, nonaxial, and musculoskeletal pain procedures is rapidly evolving and growing. Because of the lack of specialty-specific guidelines for ultrasonography in pain medicine, an international collaborative effort consisting of members of the Special Interest Group on Ultrasonography in Pain Medicine from the American Society of Regional Anesthesia and Pain Medicine, the European Society of Regional Anaesthesia and Pain Therapy, and the Asian Australasian Federation of Pain Societies developed the following recommendations for education and training in ultrasound-guided interventional pain procedures. The purpose of these recommendations is to define the required skills for performing ultrasound-guided pain procedures, the processes for appropriate education, and training and quality improvement. Training algorithms are outlined for practice- and fellowship-based pathways. The previously published American Society of Regional Anesthesia and Pain Medicine and European Society of Regional Anaesthesia and Pain Therapy education and teaching recommendations for ultrasound-guided regional anesthesia served as a foundation for the pain medicine recommendations. Although the decision to grant ultrasound privileges occurs at the institutional level, the committee recommends that the training guidelines outlined in this document serve as the foundation for educational training and the advancement of the practice of ultrasonography in pain medicine.

  1. Endoscopic ultrasound-guided biliary drainage

    PubMed Central

    Chavalitdhamrong, Disaya; Draganov, Peter V

    2012-01-01

    Endoscopic ultrasound (EUS)-guided biliary drainage has emerged as a minimally invasive alternative to percutaneous and surgical interventions for patients with biliary obstruction who had failed endoscopic retrograde cholangiopancreatography (ERCP). EUS-guided biliary drainage has become feasible due to the development of large channel curvilinear therapeutic echo-endoscopes and the use of real-time ultrasound and fluoroscopy imaging in addition to standard ERCP devices and techniques. EUS-guided biliary drainage is an attractive option because of its minimally invasive, single step procedure which provides internal biliary decompression. Multiple investigators have reported high success and low complication rates. Unfortunately, high quality prospective data are still lacking. We provide detailed review of the use of EUS for biliary drainage from the perspective of practicing endoscopists with specific focus on the technical aspects of the procedure. PMID:22363114

  2. Effect of Transversus Abdominis Plane Block on Cost of Laparoscopic Cholecystectomy Anesthesia

    PubMed Central

    Kokulu, Serdar; Bakı, Elif Doğan; Kaçar, Emre; Bal, Ahmet; Şenay, Hasan; Üstün, Kübra Demir; Yılmaz, Sezgin; Ela, Yüksel; Sıvacı, Remziye Gül

    2014-01-01

    Background Use of transversus abdominis plane (TAP) block for postoperative analgesia is continuously increasing. However, few studies have investigated intraoperative effects of TAP block. We aimed to study the effects of TAP block in terms of cost-effectiveness and consumption of inhalation agents. Material/Methods Forty patients undergoing laparoscopic cholecystectomy were enrolled in this study. Patients were randomly divided into 2 groups: Group 1 (n=20) patients received TAP block and Group 2 (n=20) patients did not receive TAP block. Standard anesthesia induction was used in all patients. For the maintenance of anesthesia, fractional inspired oxygen (FIO2) of 50% in air with desflurane was used with a fresh gas flow of 4 L/min. All patients were monitored with electrocardiography and for peripheral oxygen saturation (SpO2), end-tidal carbon dioxide (ET), heart rate (HR), noninvasive mean blood pressure (MBP), and bispectral index (BIS). Bilateral TAP blocks were performed under ultrasound guidance to Group 1 patients. The BIS value was maintained at between 40 and 50 during the surgery. The Dion formula was used to calculate consumption of desflurane for each patient. Results There was no difference between the groups with respect to demographic characteristics of the patients. Duration of anesthesia, surgery time, and dosage of fentanyl were similar in the 2 groups. However, the cost and consumption of desflurane was significantly lower in Group 1. Conclusions Total anesthesia consumption was lower and the cost-effectiveness of anesthesia was better in TAP block patients with general anesthesia than in non-TAP block patients undergoing laparoscopic cholecystectomy. PMID:25534331

  3. Effect of transversus abdominis plane block on cost of laparoscopic cholecystectomy anesthesia.

    PubMed

    Kokulu, Serdar; Bakı, Elif Doğan; Kaçar, Emre; Bal, Ahmet; Şenay, Hasan; Üstün, Kübra Demir; Yılmaz, Sezgin; Ela, Yüksel; Sıvacı, Remziye Gül

    2014-12-23

    Use of transversus abdominis plane (TAP) block for postoperative analgesia is continuously increasing. However, few studies have investigated intraoperative effects of TAP block. We aimed to study the effects of TAP block in terms of cost-effectiveness and consumption of inhalation agents. Forty patients undergoing laparoscopic cholecystectomy were enrolled in this study. Patients were randomly divided into 2 groups: Group 1 (n=20) patients received TAP block and Group 2 (n=20) patients did not receive TAP block. Standard anesthesia induction was used in all patients. For the maintenance of anesthesia, fractional inspired oxygen (FIO2) of 50% in air with desflurane was used with a fresh gas flow of 4 L/min. All patients were monitored with electrocardiography and for peripheral oxygen saturation (SpO2), end-tidal carbon dioxide (ET), heart rate (HR), noninvasive mean blood pressure (MBP), and bispectral index (BIS). Bilateral TAP blocks were performed under ultrasound guidance to Group 1 patients. The BIS value was maintained at between 40 and 50 during the surgery. The Dion formula was used to calculate consumption of desflurane for each patient. There was no difference between the groups with respect to demographic characteristics of the patients. Duration of anesthesia, surgery time, and dosage of fentanyl were similar in the 2 groups. However, the cost and consumption of desflurane was significantly lower in Group 1. Total anesthesia consumption was lower and the cost-effectiveness of anesthesia was better in TAP block patients with general anesthesia than in non-TAP block patients undergoing laparoscopic cholecystectomy.

  4. High-Intensity Focused Ultrasound: Current Status for Image-Guided Therapy

    PubMed Central

    Copelan, Alexander; Hartman, Jason; Chehab, Monzer; Venkatesan, Aradhana M.

    2015-01-01

    Image-guided high-intensity focused ultrasound (HIFU) is an innovative therapeutic technology, permitting extracorporeal or endocavitary delivery of targeted thermal ablation while minimizing injury to the surrounding structures. While ultrasound-guided HIFU was the original image-guided system, MR-guided HIFU has many inherent advantages, including superior depiction of anatomic detail and superb real-time thermometry during thermoablation sessions, and it has recently demonstrated promising results in the treatment of both benign and malignant tumors. HIFU has been employed in the management of prostate cancer, hepatocellular carcinoma, uterine leiomyomas, and breast tumors, and has been associated with success in limited studies for palliative pain management in pancreatic cancer and bone tumors. Nonthermal HIFU bioeffects, including immune system modulation and targeted drug/gene therapy, are currently being explored in the preclinical realm, with an emphasis on leveraging these therapeutic effects in the care of the oncology patient. Although still in its early stages, the wide spectrum of therapeutic capabilities of HIFU offers great potential in the field of image-guided oncologic therapy. PMID:26622104

  5. Correlation Between Cycling Power and Muscle Thickness in Cyclists.

    PubMed

    Lee, Hyung-Jin; Lee, Kang-Woo; Lee, Yong-Woo; Kim, Hee-Jin

    2018-05-17

    The aim of this study was to determine the correlation between muscle thickness (MT) and cycling power in varsity cyclists using ultrasonography (US) and to identify any differences in MT between short- and long-distance cyclists. Twelve cyclists participated in this study. Real-time two-dimensional B-mode US was used to measure the MT in the anterior thigh, anterior lower leg, and trunk, especially in the abdominal and lumbar regions. A Wattbike cycle ergometer was used to measure cycling power parameters such as maximum anaerobic power (over 5 s), mean anaerobic power (over 30 s), and aerobic power (over 3 min). This study was approved by the Ethics Committee of Korea National Sports University. There was a significant relationship between the MT and cycling power for the rectus femoris (RF) and vastus lateralis (VL) in the thigh, the rectus abdominis (RA) in the abdominal region, and the erector spinae (ES) in the lower back. The MT values of the RF, VL, and ES were strongly associated with the maximum and mean anaerobic power. There were significant differences between short- and long-distance cyclists in the MT of the RF in the thigh, the RA, the external abdominal oblique, the internal abdominal oblique, and the transverse abdominis muscle in the abdomen. We suggest that training programs attempting to improve cycling performance focus on improving the VL and ES via resistance weight or cycle training and also the core muscles for short-distance cyclists. This article is protected by copyright. All rights reserved. © 2018 Wiley Periodicals, Inc.

  6. Mechanics of lung ventilation in a large aquatic salamander, siren lacertina

    PubMed

    Brainerd; j

    1998-06-01

    Lung ventilation in Siren lacertina was studied using X-ray video, measurements of body cavity pressure and electromyography of hypaxial muscles. S. lacertina utilizes a two-stroke buccal pump in which mixing of expired and inspired gas is minimized by partial expansion of the buccal cavity during exhalation and then full expansion after exhalation is complete. Mixing is further reduced by the use of one or two accessory inspirations after the first, mixed-gas cycle. Exhalation occurs in two phases: a passive phase in which hydrostatic pressure and possibly lung elasticity force air out of the lungs, and an active phase in which contraction of the transverse abdominis (TA) muscle increases body cavity pressure and forces most of the remaining air out. In electromyograms of the lateral hypaxial musculature, the TA became active 200-400 ms before the rise in body cavity pressure, and activity ceased at peak pressure. The TA was not active during inspiration, and no consistent activity during breathing was noted in the external oblique, internal oblique and rectus abdominis muscles. The finding that the TA is the primary expiratory muscle in S. lacertina agrees with findings in a previous study of another salamander, Necturus maculosus. Together, these results indicate that the use of the TA for exhalation is a primitive character for salamanders and support the hypothesis that the breathing mechanism of salamanders represents an intermediate step in evolution between a buccal pump, in which only head muscles are used for ventilation, and an aspiration pump, in which axial muscles are used for both exhalation and inhalation.

  7. Backscattering analysis of high frequency ultrasonic imaging for ultrasound-guided breast biopsy

    NASA Astrophysics Data System (ADS)

    Cummins, Thomas; Akiyama, Takahiro; Lee, Changyang; Martin, Sue E.; Shung, K. Kirk

    2017-03-01

    A new ultrasound-guided breast biopsy technique is proposed. The technique utilizes conventional ultrasound guidance coupled with a high frequency embedded ultrasound array located within the biopsy needle to improve the accuracy in breast cancer diagnosis.1 The array within the needle is intended to be used to detect micro- calcifications indicative of early breast cancers such as ductal carcinoma in situ (DCIS). Backscattering analysis has the potential to characterize tissues to improve localization of lesions. This paper describes initial results of the application of backscattering analysis of breast biopsy tissue specimens and shows the usefulness of high frequency ultrasound for the new biopsy related technique. Ultrasound echoes of ex-vivo breast biopsy tissue specimens were acquired by using a single-element transducer with a bandwidth from 41 MHz to 88 MHz utilizing a UBM methodology, and the backscattering coefficients were calculated. These values as well as B-mode image data were mapped in 2D and matched with each pathology image for the identification of tissue type for the comparison to the pathology images corresponding to each plane. Microcalcifications were significantly distinguished from normal tissue. Adenocarcinoma was also successfully differentiated from adipose tissue. These results indicate that backscattering analysis is able to quantitatively distinguish tissues into normal and abnormal, which should help radiologists locate abnormal areas during the proposed ultrasound-guided breast biopsy with high frequency ultrasound.

  8. Feasibility and limits of inguinal hernia repair under local anaesthesia in a limited resource environment: a prospective controlled study.

    PubMed

    Bourgouin, S; Goudard, Y; Montcriol, A; Bordes, J; Nau, A; Balandraud, P

    2017-10-01

    Local anaesthesia (LA) has proven effective for inguinal hernia repair in developed countries. Hernias in low to middle income countries represent a different issue. The aim of this study was to analyse the feasibility of LA for African hernia repairs in a limited resource environment. Data from patients who underwent herniorrhaphy under LA or spinal anaesthesia (SA) by the 6th and 7th Forward Surgical Team were prospectively collected. All of the patients benefited from a transversus abdominis plane (TAP) block for postoperative analgesia. Primary endpoints concerned the pain response and conversion to general anaesthesia. Secondary endpoints concerned the complication and recurrence rates. Predictors of LA failure were then identified. In all, 189 inguinal hernias were operated during the study period, and 119 patients fulfilled the inclusion criteria: 57 LA and 62 SA. Forty-eight percent of patients presented with inguinoscrotal hernias. Local anaesthesia led to more pain during surgery and necessitated more administration of analgesics but resulted in fewer micturition difficulties and better postoperative pain control. Conversion rates were not different. Inguinoscrotal hernia and a time interval <50 min between the TAP block and skin incision were predictors of LA failure. Forty-four patients were followed-up at one month. No recurrence was noted. Local anaesthesia is a safe alternative to SA. Small or medium hernias can easily be performed under LA in rural centres, but inguinoscrotal hernias required an ultrasound-guided TAP block performed 50 min before surgery to achieve optimal analgesia, and should be managed only in centres equipped with ultrasonography.

  9. Intravascular ultrasound guided directional atherectomy versus directional atherectomy guided by angiography for the treatment of femoropopliteal in-stent restenosis.

    PubMed

    Krishnan, Prakash; Tarricone, Arthur; K-Raman, Purushothaman; Majeed, Farhan; Kapur, Vishal; Gujja, Karthik; Wiley, Jose; Vasquez, Miguel; Lascano, Rheoneil A; Quiles, Katherine G; Distin, Tashanne; Fontenelle, Ran; Atallah-Lajam, Farah; Kini, Annapoorna; Sharma, Samin

    2018-01-01

    The aim of this study was to compare 1-year outcomes for patients with femoropopliteal in-stent restenosis using directional atherectomy guided by intravascular ultrasound (IVUS) versus directional atherectomy guided by angiography. This was a retrospective analysis for patients with femoropopliteal in-stent restenosis treated with IVUS-guided directional atherectomy versus directional atherectomy guided by angiography from a single center between March 2012 and February 2016. Clinically driven target lesion revascularization was the primary endpoint and was evaluated through medical chart review as well as phone call follow up. Directional atherectomy guided by IVUS reduces clinically driven target lesion revascularization for patients with femoropopliteal in-stent restenosis.

  10. Accuracy of non-operative identification of the sentinel lymph node using combined gamma and ultrasound scanning.

    PubMed

    Whelehan, P; Vinnicombe, S J; Brown, D C; McLean, D; Evans, A

    2014-08-01

    To assess how accurately the sentinel lymph node (SLN) can be identified percutaneously, using gamma probe and ultrasound technology. Women with breast cancer, scheduled for wide local excision or mastectomy with SLN biopsy (SLNB), were included. Peri-areolar intradermal injection of technetium-99 nanocolloid was performed on the morning of surgery and 1-2 ml of blue dye was injected in the peri-areolar region once the patient was anaesthetized. Prior to surgery, a gamma probe was used over the skin to identify any hot spot that could represent a SLN. Ultrasound, guided by the hot spot, was then used to visualize potential SLNs and guide the insertion of a localizing wire. The accuracy in localizing the SLN by preoperative gamma-probe guided ultrasonography was assessed by comparison to SLNB. A SLN was correctly identified and marked using gamma-probe guided ultrasonography in 44 of 59 cases (75%; 95% CI: 63-86%). This study supports the case for investigating percutaneous gamma probe and ultrasound guided interventions in the axilla in women with breast cancer, as a potential alternative to surgical SLNB. Copyright © 2014 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  11. [An integrated segmentation method for 3D ultrasound carotid artery].

    PubMed

    Yang, Xin; Wu, Huihui; Liu, Yang; Xu, Hongwei; Liang, Huageng; Cai, Wenjuan; Fang, Mengjie; Wang, Yujie

    2013-07-01

    An integrated segmentation method for 3D ultrasound carotid artery was proposed. 3D ultrasound image was sliced into transverse, coronal and sagittal 2D images on the carotid bifurcation point. Then, the three images were processed respectively, and the carotid artery contours and thickness were obtained finally. This paper tries to overcome the disadvantages of current computer aided diagnosis method, such as high computational complexity, easily introduced subjective errors et al. The proposed method could get the carotid artery overall information rapidly, accurately and completely. It could be transplanted into clinical usage for atherosclerosis diagnosis and prevention.

  12. Efficiency of quantitative echogenicity for investigating supraspinatus tendinopathy by the gray-level histogram of two ultrasound devices.

    PubMed

    Hsu, Jiun-Cheng; Chen, Po-Han; Huang, Kuo-Chin; Tsai, Yao-Hung; Hsu, Wei-Hsiu

    2017-10-01

    The gray-level histogram of ultrasound is a promising tool for scanning the hypoechogenic appearance of supraspinatus tendinopathy, and the aim of this study was to test the hypothesis that the gray-level value of the supraspinatus tendon in the painful shoulder has a lower value on B-mode images even though in different ultrasound devices. Sixty-seven patients who had unilateral shoulder pain with rotator cuff tendinopathy underwent bilateral shoulder ultrasonography, and we compared the mean gray-level values of painful shoulders and contralateral shoulders without any pain in each patient using two ultrasound devices. The echogenicity ratio (symptomatic/asymptomatic side) of two ultrasound devices was compared. A significant difference existed between the symptomatic shoulder and contralateral asymptomatic shoulder (p < 0.001) on the mean gray-level value measurements of each device. The symptomatic-to-asymptomatic tendon echogenicity ratio of device A was 0.919 ± 0.090 in the transverse plane and 0.937 ± 0.081 in the longitudinal plane, and the echogenicity ratio of device B was 0.899 ± 0.113 in the transverse plane and 0.940 ± 0.113 in the longitudinal plane. The decline of the mean gray-level value and the echogenicity ratio of the supraspinatus tendon in the painful shoulder may be utilized as a useful sonographic reference of unilateral rotator cuff lesions. Diagnostic level III.

  13. Ultrasound for the Anesthesiologists: Present and Future

    PubMed Central

    Terkawi, Abdullah S.; Karakitsos, Dimitrios; Elbarbary, Mahmoud; Blaivas, Michael; Durieux, Marcel E.

    2013-01-01

    Ultrasound is a safe, portable, relatively inexpensive, and easily accessible imaging modality, making it a useful diagnostic and monitoring tool in medicine. Anesthesiologists encounter a variety of emergent situations and may benefit from the application of such a rapid and accurate diagnostic tool in their routine practice. This paper reviews current and potential applications of ultrasound in anesthesiology in order to encourage anesthesiologists to learn and use this useful tool as an adjunct to physical examination. Ultrasound-guided peripheral nerve blockade and vascular access represent the most popular ultrasound applications in anesthesiology. Ultrasound has recently started to substitute for CT scans and fluoroscopy in many pain treatment procedures. Although the application of airway ultrasound is still limited, it has a promising future. Lung ultrasound is a well-established field in point-of-care medicine, and it could have a great impact if utilized in our ORs, as it may help in rapid and accurate diagnosis in many emergent situations. Optic nerve sheath diameter (ONSD) measurement and transcranial color coded duplex (TCCD) are relatively new neuroimaging modalities, which assess intracranial pressure and cerebral blood flow. Gastric ultrasound can be used for assessment of gastric content and diagnosis of full stomach. Focused transthoracic (TTE) and transesophageal (TEE) echocardiography facilitate the assessment of left and right ventricular function, cardiac valve abnormalities, and volume status as well as guiding cardiac resuscitation. Thus, there are multiple potential areas where ultrasound can play a significant role in guiding otherwise blind and invasive interventions, diagnosing critical conditions, and assessing for possible anatomic variations that may lead to plan modification. We suggest that ultrasound training should be part of any anesthesiology training program curriculum. PMID:24348179

  14. Comparison of abdominal muscle activity and peak expiratory flow between forced vital capacity and fast expiration exercise.

    PubMed

    Ishida, Hiroshi; Suehiro, Tadanobu; Watanabe, Susumu

    2017-04-01

    [Purpose] The purpose of this investigation was to compare the activities of the abdominal muscles and peak expiratory flow between forced vital capacity and fast expiration exercise. [Subjects and Methods] Fifteen healthy male participated in this study. Peak expiratory flow and electromyographic activities of the rectus abdominis, external oblique, and internal oblique/transversus abdominis muscles were measured during forced vital capacity and fast expiration exercise and then peak amplitude and its appearance time were obtained. [Results] Peak expiratory flow values were significantly higher during fast expiration exercise than during forced vital capacity. The internal oblique/transversus abdominis muscles showed significantly higher peak amplitude during fast expiration exercise than during forced vital capacity. However, there were no significant differences between forced vital capacity and fast expiration exercise in the rectus abdominis and external oblique muscles. There was no difference in the appearance time of the peak amplitude between forced vital capacity and fast expiration exercise in any muscle. [Conclusion] Fast expiration exercise might be beneficial for increasing expiratory speed and neuromuscular activation of the internal oblique/transversus abdominis muscles compared to forced vital capacity. These findings could be considered when recommending a variation of expiratory muscle strength training as part of pulmonary rehabilitation programs.

  15. [Prognostic analysis of plantar fasciitis treated by pneumatic ballistic extracorporeal shock wave versus ultrasound guided intervention].

    PubMed

    Huo, Xiu-Lin; Wang, Ke-Tao; Zhang, Xiao-Ying; Yang, Yi-Tian; Cao, Fu-Yang; Yang, Jing; Yuan, Wei-Xiu; Mi, Wei-Dong

    2018-02-20

    To compare the medium- and long-term effect of pneumatic ballistic extracorporeal shock wave versus ultrasound-guided hormone injection in the treatment of plantar fasciitis. The clinical data were collected from patients with plantar fasciitis admitted to PLA General Hospital pain department from September, 2015 to February, 2017. The patients were randomly divided into ultrasound-guided drug injection group and shock wave group. The therapeutic parameters including the numerical rating scale (NRS) scores in the first step pain in the morning, American Orthopedic Foot and Ankle Society (AOFAS) Ankle Hindfoot Scale, and thickness of the plantar fascia were monitored before and at 1 week, 1 month, 3 months, and 6 months after the treatment. The recurrence rate, effectiveness, and patient satisfaction were compared between the two groups at 6 months after the treatment. Thirty-nine patients were enrolled in shock wave group and 38 patients in ultrasound group. The NRS scores in the first step pain in the morning were lowered after treatment in both groups (P<0.05), and the scores were significantly lower in ultrasound group than in shock wave group at 1 week and 1 month (P<0.01), but significantly higher in ultrasound group than in shock wave group at 3 and 6 months after treatment (P<0.05). The AOFAS functional scores were increased in both groups (P<0.05) at 6 months after treatment, was significantly lower in ultrasound group than in shock wave group than group B (90.44∓13.27 vs 75.76∓21.40; P<0.05). The effective rates in shock wave group and ultrasound group were 92.31% and 76.32%, respectively (P<0.05). Recurrence was found in 1 patient (2.56%) in shock wave group and in 8 (21.05%) in ultrasound group (P<0.05). The patient satisfaction scores were significantly higher in shock wave group than in ultrasound group (8.13∓2.67 vs 6.63∓3.75, P=0.048). Pneumatic ballistic extracorporeal shock achieves better medium- and long-term outcomes than ultrasound-guided hormone injection in the treatment of plantar fasciitis.

  16. Spinal curvature measurement by tracked ultrasound snapshots.

    PubMed

    Ungi, Tamas; King, Franklin; Kempston, Michael; Keri, Zsuzsanna; Lasso, Andras; Mousavi, Parvin; Rudan, John; Borschneck, Daniel P; Fichtinger, Gabor

    2014-02-01

    Monitoring spinal curvature in adolescent kyphoscoliosis requires regular radiographic examinations; however, the applied ionizing radiation increases the risk of cancer. Ultrasound imaging is favored over radiography because it does not emit ionizing radiation. Therefore, we tested an ultrasound system for spinal curvature measurement, with the help of spatial tracking of the ultrasound transducer. Tracked ultrasound was used to localize vertebral transverse processes as landmarks along the spine to measure curvature angles. The method was tested in two scoliotic spine models by localizing the same landmarks using both ultrasound and radiographic imaging and comparing the angles obtained. A close correlation was found between tracked ultrasound and radiographic curvature measurements. Differences between results of the two methods were 1.27 ± 0.84° (average ± SD) in an adult model and 0.96 ± 0.87° in a pediatric model. Our results suggest that tracked ultrasound may become a more tolerable and more accessible alternative to radiographic spine monitoring in adolescent kyphoscoliosis. Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  17. Mondor's disease of the breast as a complication of ultrasound-guided core needle biopsy: management and review of the literature.

    PubMed

    Salemis, Nikolaos S; Vasilara, Georgia; Lagoudianakis, Emmanuel

    2015-01-01

    Mondor's disease is a rare benign and self-limiting condition characterized by thrombophlebitis of the superficial veins of the anterolateral thoracoabdominal wall. We describe a case of Mondor's disease of the breast as a complication of an ultrasound-guided core needle biospy. The patient presented with a palpable cord-like structure in her left breast, associated with severe pain and tenderness. She was treated concervatively and complete resolution was observed after four weeks. We conclude that emergency clinicians and interventional breast radiologists should be aware of Mondor's disease as a potential complication of ultrasound-guided core needle biopsy of the breast.

  18. Targeted Ultrasound-Guided Perineural Hydrodissection of the Sciatic Nerve for the Treatment of Piriformis Syndrome.

    PubMed

    Burke, Christopher J; Walter, William R; Adler, Ronald S

    2018-05-01

    Piriformis syndrome is a common cause of lumbar, gluteal, and thigh pain, frequently associated with sciatic nerve symptoms. Potential etiologies include muscle injury or chronic muscle stretching associated with gait disturbances. There is a common pathological end pathway involving hypertrophy, spasm, contracture, inflammation, and scarring of the piriformis muscle, leading to impingement of the sciatic nerve. Ultrasound-guided piriformis injections are frequently used in the treatment of these pain syndromes, with most of the published literature describing injection of the muscle. We describe a safe, effective ultrasound-guided injection technique for the treatment of piriformis syndrome using targeted sciatic perineural hydrodissection followed by therapeutic corticosteroid injection.

  19. Delphi Method Validation of a Procedural Performance Checklist for Insertion of an Ultrasound-Guided Internal Jugular Central Line.

    PubMed

    Hartman, Nicholas; Wittler, Mary; Askew, Kim; Manthey, David

    2016-01-01

    Placement of ultrasound-guided central lines is a critical skill for physicians in several specialties. Improving the quality of care delivered surrounding this procedure demands rigorous measurement of competency, and validated tools to assess performance are essential. Using the iterative, modified Delphi technique and experts in multiple disciplines across the United States, the study team created a 30-item checklist designed to assess competency in the placement of ultrasound-guided internal jugular central lines. Cronbach α was .94, indicating an excellent degree of internal consistency. Further validation of this checklist will require its implementation in simulated and clinical environments. © The Author(s) 2014.

  20. Septic bursitis after ultrasound-guided percutaneous treatment of rotator cuff calcific tendinopathy.

    PubMed

    Sconfienza, Luca Maria; Randelli, Filippo; Sdao, Silvana; Sardanelli, Francesco; Randelli, Pietro

    2014-08-01

    Calcific tendinopathy of the rotator cuff is a common condition. Ultrasound-guided percutaneous aspiration is one of several options to treat this condition. The main advantages of this procedure are short duration, good outcome, and low cost. Furthermore, only minor complications have been reported in the literature, namely, vagal reactions during the procedure and mild postprocedural pain. We report the first case of septic bursitis after ultrasound-guided percutaneous treatment of calcific tendinopathy. Although this is generally considered a very safe procedure, a risk of infection should be taken into account. Copyright © 2014 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  1. Treatment of great auricular neuralgia with real-time ultrasound-guided great auricular nerve block

    PubMed Central

    Jeon, Younghoon; Kim, Saeyoung

    2017-01-01

    Abstract Rationale: The great auricular nerve can be damaged by the neck surgery, tumor, and long-time pressure on the neck. But, great auricular neuralgia is very rare condition. It was managed by several medication and landmark-based great auricular nerve block with poor prognosis. Patient concerns: A 25-year-old man presented with a pain in the left lateral neck and auricle. Diagnosis: He was diagnosed with great auricular neuralgia. Interventions: His pain was not reduced by medication. Therefore, the great auricular nerve block with local anesthetics and steroid was performed under ultrasound guidance. Outcomes: Ultrasound guided great auricular nerve block alleviated great auricular neuralgia. Lessons: This medication-resistant great auricular neuralgia was treated by the ultrasound guided great auricular nerve block with local anesthetic agent and steroid. Therefore, great auricular nerve block can be a good treatment option of medication resistant great auricular neuralgia. PMID:28328811

  2. Observation of transverse Anderson localization in an optical fiber.

    PubMed

    Karbasi, Salman; Mirr, Craig R; Yarandi, Parisa Gandomkar; Frazier, Ryan J; Koch, Karl W; Mafi, Arash

    2012-06-15

    We utilize transverse Anderson localization as the waveguiding mechanism in optical fibers with random transverse refractive index profiles. Using experiments and numerical simulations, we show that the transverse localization results in an effective propagating beam diameter that is comparable to that of a typical index-guiding optical fiber.

  3. Evolution of transversus abdominis plane infiltration techniques for postsurgical analgesia following abdominal surgeries.

    PubMed

    Gadsden, Jeffrey; Ayad, Sabry; Gonzales, Jeffrey J; Mehta, Jaideep; Boublik, Jan; Hutchins, Jacob

    2015-01-01

    Transversus abdominis plane (TAP) infiltration is a regional anesthesia technique that has been demonstrated to be effective for management of postsurgical pain after abdominal surgery. There are several different clinical variations in the approaches used for achieving analgesia via TAP infiltration, and methods for identification of the TAP have evolved considerably since the landmark-guided technique was first described in 2001. There are many factors that impact the analgesic outcomes following TAP infiltration, and the various nuances of this technique have led to debate regarding procedural classification of TAP infiltration. Based on our current understanding of fascial and neuronal anatomy of the anterior abdominal wall, as well as available evidence from studies assessing local anesthetic spread and cutaneous sensory block following TAP infiltration, it is clear that TAP infiltration techniques are appropriately classified as field blocks. While the objective of peripheral nerve block and TAP infiltration are similar in that both approaches block sensory response in order to achieve analgesia, the technical components of the two procedures are different. Unlike peripheral nerve block, which involves identification or stimulation of a specific nerve or nerve plexus, followed by administration of a local anesthetic in close proximity, TAP infiltration involves administration and spread of local anesthetic within an anatomical plane of the surgical site.

  4. In-vivo ultrasound and photoacoustic image- guided photothermal cancer therapy using silica-coated gold nanorods.

    PubMed

    Kim, Seungsoo; Chen, Yun-Sheng; Luke, Geoffrey P; Emelianov, Stanislav Y

    2014-05-01

    In nanoparticle-augmented photothermal therapy, evaluating the delivery and spatial distribution of nanoparticles, followed by remote temperature mapping and monitoring, is essential to ensure the optimal therapeutic outcome. The utility of ultrasound and photoacoustic imaging to assist photothermal therapy has been previously demonstrated. Here, using a mouse xenograft tumor model, it is demonstrated in vivo that ultrasound-guided photoacoustic imaging can be used to plan the treatment and to guide the therapy. To evaluate nanoparticle delivery and spatial distribution, three-dimensional ultrasound and spectroscopic photoacoustic imaging of a mouse with a tumor was performed before and after intravenous injection of silica-coated gold nanorods. After injection and sufficient circulation of nanoparticles, photothermal therapy was performed for 5 min using an 808-nm continuous-wave laser. During the photothermal therapy, photoacoustic images were acquired continuously and used to measure the temperature changes within tissue. A heterogeneous distribution of temperature, which was spatially correlated with the measured distribution of nanoparticles, indicated that peak temperatures of 53°C were achieved in the tumor. An Arrhenius thermal damage model determined that this thermal deposition would result in significant cell death. The results of this study suggest that ultrasound and photoacoustic imaging can effectively guide photothermal therapy to achieve the desired thermal treatment.

  5. The transverse ligament as a landmark for tibial sagittal insertions of the anterior cruciate ligament: a cadaveric study.

    PubMed

    Kongcharoensombat, Wirat; Ochi, Mitsuo; Abouheif, Mohamed; Adachi, Nobuo; Ohkawa, Shingo; Kamei, Goki; Okuhara, Atushi; Shibuya, Hoyatoshi; Niimoto, Takuya; Nakasa, Tomoyuki; Nakamae, Atsuo; Deie, Masataka

    2011-10-01

    The purpose of this study was to determine the relation between the position of the transverse ligament, the anterior edge of the anterior cruciate ligament (ACL) tibial footprint, and the center of the ACL tibial insertion. We used arthroscopy for localization of the anatomic landmarks, followed by insertions of guide pins under direct visualization, and then the position of these guide pins was checked on plain lateral radiographs. The transverse ligament and the anterior aspect of the ACL tibial footprint were identified by arthroscopy in 20 unpaired cadaveric knees (10 left and 10 right). Guide pins were inserted with tibial ACL adapter drill guides under direct observation at the transverse ligament, the anterior aspect of the tibial footprint, and the center of tibial insertion of the ACL. Then, plain lateral radiographs of specimens were taken. The Amis and Jakob line was used to define the attachment of the ACL tibial insertion and the transverse ligament. A sagittal percentage of the location of the insertion point was determined and calculated from the anterior margin of the tibia in the anteroposterior direction. The transverse ligament averaged 21.20% ± 4.1%, the anterior edge of the ACL tibial insertion averaged 21.60% ± 4.0%, and the center of the ACL tibial insertion averaged 40.30% ± 4.8%. There were similar percent variations between the transverse ligament and the anterior edge of the ACL tibial insertion, with no significant difference between them (P = .38). Intraobserver and interobserver reliability was high, with small standard errors of measurement. This study shows that the transverse ligament coincides with the anterior edge of the ACL tibial footprint in the sagittal plane. The transverse ligament can be considered as a new landmark for tibial tunnel positioning during anatomic ACL reconstruction. Copyright © 2011 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  6. Value of Artisanal Simulators to Train Veterinary Students in Performing Invasive Ultrasound-Guided Procedures

    ERIC Educational Resources Information Center

    Hage, Maria Cristina F. N. S.; Massaferro, Ana Beatriz; Lopes, Érika Rondon; Beraldo, Carolina Mariano; Daniel, Jéssika

    2016-01-01

    Pericardial effusion can lead to cardiac tamponade, which endangers an animal's life. Ultrasound-guided pericardiocentesis is used to remove abnormal liquid; however, it requires technical expertise. In veterinary medical education, the opportunity to teach this procedure to save lives during emergencies is rare; therefore, simulators are…

  7. Perioperative ultrasound-guided wire marking of calcific deposits in calcifying tendinitis of the rotator cuff.

    PubMed

    Sigg, Andreas; Draws, Detlev; Stamm, Axel; Pfeiffer, Michael

    2011-03-01

    The identification of a calcific deposit in the rotator cuff can often cause difficulties. A new technique is described to identify the calcific deposit perioperatively with a ultrasound-guided wire. The technique allows a safe direct marking of calcific deposits making the procedure faster especially in difficult cases.

  8. Endobronchial ultrasound-guided transbronchial needle injection for local control of recurrent non-small cell lung cancer.

    PubMed

    Khan, Farrah; Anker, Christopher J; Garrison, Garth; Kinsey, C Matthew

    2015-01-01

    Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is an established technique for the diagnosis of thoracic malignancies. Non-ultrasound-guided transbronchial needle injection has been used previously to deliver chemotherapeutic agents. To use endobronchial ultrasound-guided transbronchial needle injection (EBUS-TBNI) to achieve local control of recurrent early-stage lung cancer. A 63-year-old man presented with recurrent early stage non-small cell lung carcinoma after chemotherapy and external beam radiation. We used EBUS-TBNI to deliver cisplatin into the tumor located outside the airway. This procedure was performed on three separate occasions without complication. EBUS-TBNI resulted in resolution of fluorodeoxyglucose avidity, measured by positron emission tomography-computed tomography, in the region at 4 weeks. However, at 5 months, there was evidence of distal recurrence. This is the first description of EBUS-TBNI to treat local recurrence of lung cancer and one of the first reports of the use of EBUS for intratumoral therapy. Additional research is warranted to determine the clinical usefulness and safety of this therapeutic approach.

  9. [Ultrasound findings in rhabdomyolysis].

    PubMed

    Carrillo-Esper, Raúl; Galván-Talamantes, Yazmin; Meza-Ayala, Cynthia Margarita; Cruz-Santana, Julio Alberto; Bonilla-Reséndiz, Luis Ignacio

    Rhabdomyolysis is defined as skeletal muscle necrosis. Ultrasound assessment has recently become a useful tool for the diagnosis and monitoring of muscle diseases, including rhabdomyolysis. A case is presented on the ultrasound findings in a patient with rhabdomyolysis. To highlight the importance of ultrasound as an essential part in the diagnosis in rhabdomyolysis, to describe the ultrasound findings, and review the literature. A 30 year-old with post-traumatic rhabdomyolysis of both thighs. Ultrasound was performed using a Philips Sparq model with a high-frequency linear transducer (5-10MHz), in low-dimensional scanning mode (2D), in longitudinal and transverse sections at the level of both thighs. The images obtained showed disorganisation of the orientation of the muscle fibres, ground glass image, thickening of the muscular fascia, and the presence of anechoic areas. Ultrasound is a useful tool in the evaluation of rhabdomyolysis. Copyright © 2015 Academia Mexicana de Cirugía A.C. Publicado por Masson Doyma México S.A. All rights reserved.

  10. Assessment of Ultrasound Features Predicting Axillary Nodal Metastasis in Breast Cancer: The Impact of Cortical Thickness

    PubMed Central

    Stachs, A.; Thi, A. Tra-Ha; Dieterich, M.; Stubert, J.; Hartmann, S.; Glass, Ä.; Reimer, T.; Gerber, B.

    2015-01-01

    Purpose: To evaluate the accuracy of axillary ultrasound (AUS) in detecting nodal metastasis in patients with early-stage breast cancer and to identify AUS features with high predictive power. Materials and Methods: Prospective single-center preliminary study in 105 patients with a primary diagnosis of breast cancer and clinically negative axilla. AUS was performed using a 12 MHz linear-array transducer before ultrasound-guided needle biopsy. Nodal characteristics (shape, longitudinal-transverse [LT] axis ratio, margins, cortical thickness, hyperechoic hilum) were correlated with histopathological nodal status after SLNB or axillary lymph node dissection (ALND). Results: Nodal metastases were present in 42/105 patients (40.0%). Univariate analyses showed that absence of hyperechoic hilum, round shape, LT axis ratio<2, sharp margins and cortical thickness>3 mm were associated with lymph node metastasis. Multivariate logistic regression analysis revealed cortical thickness > 3 mm as an independent predictive parameter for nodal involvement. Sensitivity, specificity, positive predictive value, negative predictive value and accuracy were 66.7, 74.6, 63.6, 77.0% and 71.4% respectively when cortical thickness > 3 mm was applied as the criterion for AUS positivity. Axillary tumor volume was low in patients with pT1/2 tumors and negative AUS, since only 3.2% of patients had > 2 metastatic lymph nodes. Conclusion: Cortical thickness>3 mm is a reliable predictor of nodal metastatic involvement. Negative AUS does not exclude lymph node metastases, but extensive axillary tumor volume is rare. PMID:27689144

  11. Evaluation of the eZono 4000 with eZGuide for ultrasound-guided procedures.

    PubMed

    Gadsden, Jeff; Latmore, Malikah; Levine, Daniel M

    2015-05-01

    Ultrasound-guided procedures are increasingly common in a variety of acute care settings, such as the operating room, critical care unit and emergency room. However, accurate judgment of needle tip position using traditional ultrasound technology is frequently difficult, and serious injury can result from inadvertently advancing beyond or through the target. Needle navigation is a recent innovation that allows the clinician to visualize the needle position and trajectory in real time as it approaches the target. A novel ultrasound machine has recently been introduced that is portable and designed for procedural guidance. The eZono 4000™ features an innovative needle navigation technology that is simple to use and permits the use of a wide range of commercially available needles, avoiding the inconvenience and cost of proprietary equipment. This article discusses this new ultrasound machine in the context of other currently available ultrasound machines featuring needle navigation.

  12. Transversus Abdominis Plane Blocks with Single-Dose Liposomal Bupivacaine in Conjunction with a Nonnarcotic Pain Regimen Help Reduce Length of Stay following Abdominally Based Microsurgical Breast Reconstruction.

    PubMed

    Jablonka, Eric M; Lamelas, Andreas M; Kim, Julie N; Molina, Bianca; Molina, Nathan; Okwali, Michelle; Samson, William; Sultan, Mark R; Dayan, Joseph H; Smith, Mark L

    2017-08-01

    Side effects associated with use of postoperative narcotics for pain control can delay recovery after abdominally based microsurgical breast reconstruction. The authors evaluated a nonnarcotic pain control regimen in conjunction with bilateral transversus abdominis plane blocks on facilitating early hospital discharge. A retrospective analysis was performed of consecutive patients who underwent breast reconstruction using abdominally based free flaps, with or without being included in a nonnarcotic protocol using intraoperative transversus abdominis plane blockade. During this period, the use of locoregional analgesia evolved from none (control), to continuous bupivacaine infusion transversus abdominis plane and catheters, to single-dose transversus abdominis plane blockade with liposomal bupivacaine solution. Demographic factors, length of stay, inpatient opioid consumption, and complications were reported for all three groups. One hundred twenty-eight consecutive patients (182 flaps) were identified. Forty patients (62 flaps) were in the infusion-liposomal bupivacaine group, 48 (66 flaps) were in the single-dose blockade-catheter group, and 40 (54 flaps) were in the control group. The infusion-liposomal bupivacaine patients had a significantly shorter hospital stay compared with the single-dose blockade-catheter group (2.65 ± 0.66 versus 3.52 ± 0.92 days; p < 0.0001) and the control group (2.65 ± 0.66 versus 4.05 ± 1.26 days; p < 0.0001). There was no significant difference in flap loss or major complications among groups. When used as part of a nonnarcotic postoperative pain regimen, transversus abdominis plane blocks performed with single injections of liposomal bupivacaine help facilitate early hospital discharge after abdominally based microsurgical breast reconstruction. A trend toward consistent discharge by postoperative day 2 was seen. This could result in significant cost savings for health care systems. Therapeutic, III.

  13. Ultrasound-guided stellate ganglion blocks combined with pharmacological and occupational therapy in Complex Regional Pain Syndrome (CRPS): a pilot case series ad interim.

    PubMed

    Wei, Karin; Feldmann, Robert E; Brascher, Anne-Kathrin; Benrath, Justus

    2014-12-01

    This preliminary and retrospective pilot case series examines a treatment concept consisting of ultrasound-guided stellate ganglion blocks (SGBs) combined with pharmacological and occupational therapy in patients with complex regional pain syndrome (CRPS) of the hand. Efficacy of combined treatment concepts and safety of ultrasound-guided SGB have not been sufficiently investigated yet. A total number of 156 blocks were evaluated in 16 patients with CRPS in a retrospective analysis. All patients received pharmacotherapy and a standard regimen of occupational therapy offered simultaneously to the SGBs. Changes in both spontaneous and evoked pain levels were assessed by numerical pain rating score before and after the last blockade of a series. Side effects were documented. The overall mean pain reduction was 63.2% regarding spontaneous and 45.3% regarding evoked pain. Mild complications, such as hoarseness or dysphagia, occurred in 13.5% of the blocks (21 SGBs). Serious complications, such as plexus paresis or accidental puncture of vessels or other structures, did not occur. Time between symptom onset and start of treatment did not affect the extent of pain reduction. The combination of ultrasound-guided SGB and simultaneous pharmacological and occupational therapy showed encouraging treatment results under conditions of this pilot case series. Assessment of efficacy of this combined treatment concept and safety of ultrasound-guided SGB require further prospective clinical studies with larger number of participants. Wiley Periodicals, Inc.

  14. MRI-guided high-intensity focused ultrasound ablation of bone: evaluation of acute findings with MR and CT imaging in a swine model.

    PubMed

    Bucknor, Matthew D; Rieke, Viola; Do, Loi; Majumdar, Sharmila; Link, Thomas M; Saeed, Maythem

    2014-11-01

    To evaluate hyperacute (<1 hour) changes on magnetic resonance (MR) and computed tomography (CT) imaging following MR-guided high-intensity focused ultrasound (MRgHIFU) in a swine bone model as a function of sonication number and energy. Experimental procedures received approval from the local Institutional Animal Care and Use Committee. MRgHIFU was used to create distal and proximal ablations in the right femur of eight pigs. Each target was dosed with four or six sonications within similar volumes. The energy dosed to the distal target was higher (419 ± 19 J) than the proximal target (324 ± 17 J). The targeted femur and contralateral control were imaged before and after ablation using MR at 3T. Qualitative changes in signal on T1-weighted, T2-weighted, and T1-weighted postcontrast images were assessed. Ablation dimensions were calculated from postcontrast MRI. The 64-slice CT images were also obtained before and after ablation and qualitative changes were assessed. MRgHIFU bone ablation size measured on average 8.5 × 21.1 × 16.2 mm (transverse × craniocaudal × anteroposterior). Interestingly, within similar prescribed volumes, increasing the number of sonications from 4 to 6 increased the depth of the intramedullary hypoenhanced zone from 2.9 mm to 6.5 mm (P < 0.001). There was no difference in the appearance of low versus high energy ablations. CT imaging did not show structural abnormalities. The number of MRgHIFU focal sonications can be used to increase the depth of treatment within the targeted bone. Unlike CT, T2-weighted and contrast-enhanced MR demonstrated the hyperacute structural changes in the femur and surrounding soft tissue. © 2013 Wiley Periodicals, Inc.

  15. 'X-ray'-free balloon dilation for totally ultrasound-guided percutaneous nephrolithotomy.

    PubMed

    Zhou, Tie; Chen, Guanghua; Gao, Xiaofeng; Zhang, Wei; Xu, Chuanliang; Li, Lei; Sun, Yinghao

    2015-04-01

    The objective of the study was to evaluate the feasibility and safety of balloon dilation for 'X-ray'-free ultrasound-guided percutaneous nephrolithotomy (PCNL). From January 2012 to December 2012, patients underwent 'X-ray'-free ultrasound-guided PCNL with Amplatz dilator (Group A). From January 2013 to April 2014, patients underwent 'X-ray'-free ultrasound-guided PCNL with balloon dilator (Group B). For balloon dilation, a 10 F fascial dilator was used to dilate the tract. Subsequently, the 6 F nephrostomy balloon (8 mm in diameter) was indwelled along the guidewire with a marked length equal to the dilation depth. Under the monitoring of ultrasound, the location of balloon was secured and disappearance of balloon waist was confirmed when the balloon was inflated at a pressure of 20 atm. A total of 163 patients were involved in this study. Of 81 procedures in Group A, 45 procedures were performed by a senior urologist while 36 procedures by a resident. Of 82 patients in Group B, 47 procedures were performed by the same senior urologist while 35 procedures by another resident. For the senior urologist, there was no statistically significant difference between two groups in calyx of entry, stone-free rate, decline of hemoglobin and hematocrit, operation time and hospitalization. But for the residents, there was less decline of hemoglobin and hematocrit, tract development time and hospitalization in Group B compared to Group A (0.6 vs. 1.7 g/dl, p = 0.001; 2.3% vs. 5.5%, p = 0.003; 10.1 vs. 11.0 min, p = 0.027; 7.8 vs. 13.9 days, p < 0.001). Balloon dilation method introduced in this study is compensable for tract development when 'X-ray'-free ultrasound-guided PCNL is performed. Modified techniques make totally ultrasound guidance for PCNL feasible, easy and safe. In addition, such a procedure is preferable for initial operators because of less hemorrhage complication.

  16. Neurologic Outcomes After Low-Volume, Ultrasound-Guided Interscalene Block and Ambulatory Shoulder Surgery.

    PubMed

    Rajpal, Gaurav; Winger, Daniel G; Cortazzo, Megan; Kentor, Michael L; Orebaugh, Steven L

    2016-01-01

    Postoperative neurologic symptoms after interscalene block and shoulder surgery have been reported to be relatively frequent. Reports of such symptoms after ultrasound-guided block have been variable. We evaluated 300 patients for neurologic symptoms after low-volume, ultrasound-guided interscalene block and arthroscopic shoulder surgery. Patients underwent ultrasound-guided interscalene block with 16 to 20 mL of 0.5% bupivacaine or a mix of 0.2% bupivacaine/1.2% mepivacaine solution, followed by propofol/ketamine sedation for ambulatory arthroscopic shoulder surgery. Patients were called at 10 days for evaluation of neurologic symptoms, and those with persistent symptoms were called again at 30 days, at which point neurologic evaluation was initiated. Details of patient demographics and block characteristics were collected to assess any association with persistent neurologic symptoms. Six of 300 patients reported symptoms at 10 days (2%), with one of these patients having persistent symptoms at 30 days (0.3%). This was significantly lower than rates of neurologic symptoms reported in preultrasound investigations with focused neurologic follow-up and similar to other studies performed in the ultrasound era. There was a modest correlation between the number of needle redirections during the block procedure and the presence of postoperative neurologic symptoms. Ultrasound guidance of interscalene block with 16- to 20-mL volumes of local anesthetic solution results in a lower frequency of postoperative neurologic symptoms at 10 and 30 days as compared with investigations in the preultrasound period.

  17. A Single Center Evaluation of the Diagnostic Accuracy of Multiparametric Magnetic Resonance Imaging against Transperineal Prostate Mapping Biopsy: An Analysis of Men with Benign Histology and Insignificant Cancer following Transrectal Ultrasound Biopsy.

    PubMed

    Pal, Raj P; Ahmad, Ros; Trecartan, Shaun; Voss, James; Ahmed, Shaista; Bazo, Alvaro; Lloyd, Jon; Walton, Thomas J

    2018-03-01

    In this study we evaluated the diagnostic performance of transrectal ultrasound guided biopsy and multiparametric magnetic resonance imaging to detect prostate cancer against transperineal prostate mapping biopsy as the reference test. Transrectal ultrasound guided biopsy, multiparametric magnetic resonance imaging and transperineal prostate mapping biopsy were performed in 426 patients between April 2012 and January 2016. Patients initially underwent systematic 12 core transrectal ultrasound guided biopsy followed 3 months later by 1.5 Tesla, high resolution T2, diffusion-weighted, dynamic contrast enhanced multiparametric magnetic resonance imaging. Two specialist uroradiologists blinded to the results of transperineal prostate mapping biopsy allocated a PI-RADS™ (Prostate Imaging-Reporting and Data System) score to each multiparametric magnetic resonance imaging study. Transperineal prostate mapping biopsy with 5 mm interval sampling, which was performed within 6 months of multiparametric magnetic resonance imaging, served as the reference test. Transrectal ultrasound guided biopsy identified 247 of 426 patients with prostate cancer and 179 of 426 with benign histology. Transperineal prostate mapping biopsy detected prostate cancer in 321 of 426 patients. On transperineal prostate mapping biopsy 94 of 179 patients with benign transrectal ultrasound guided biopsy had prostate cancer and 95 of 247 with prostate cancer on transrectal ultrasound guided biopsy were identified with cancer of higher grade. Using a multiparametric magnetic resonance imaging PI-RADS score of 3 or greater to detect significant prostate cancer, defined as any core containing Gleason 4 + 3 or greater prostate cancer on transperineal prostate mapping biopsy, the ROC AUC was 0.754 (95% CI 0.677-0.819) with 87.0% sensitivity (95% CI 77.3-97.0), 55.3% specificity (95% CI 50.2-60.4) and 97.1% negative predictive value (95% CI 94.8-99.4). Multiparametric magnetic resonance imaging is a more accurate diagnostic test than transrectal ultrasound guided biopsy. However, a significant proportion of ISUP (International Society of Urological Pathology) Grade Group 2 prostate cancer remained undetected following multiparametric magnetic resonance imaging. Although multiparametric magnetic resonance imaging could avoid unnecessary biopsy in many patients with ISUP Grade Group 3 or greater prostate cancer, at less stringent definitions of significant cancer a substantial proportion of prostate cancer would remain undetected after multiparametric magnetic resonance imaging. Copyright © 2018 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  18. Intravascular ultrasound guided directional atherectomy versus directional atherectomy guided by angiography for the treatment of femoropopliteal in-stent restenosis

    PubMed Central

    Krishnan, Prakash; Tarricone, Arthur; K-Raman, Purushothaman; Majeed, Farhan; Kapur, Vishal; Gujja, Karthik; Wiley, Jose; Vasquez, Miguel; Lascano, Rheoneil A.; Quiles, Katherine G.; Distin, Tashanne; Fontenelle, Ran; Atallah-Lajam, Farah; Kini, Annapoorna; Sharma, Samin

    2017-01-01

    Background: The aim of this study was to compare 1-year outcomes for patients with femoropopliteal in-stent restenosis using directional atherectomy guided by intravascular ultrasound (IVUS) versus directional atherectomy guided by angiography. Methods and results: This was a retrospective analysis for patients with femoropopliteal in-stent restenosis treated with IVUS-guided directional atherectomy versus directional atherectomy guided by angiography from a single center between March 2012 and February 2016. Clinically driven target lesion revascularization was the primary endpoint and was evaluated through medical chart review as well as phone call follow up. Conclusions: Directional atherectomy guided by IVUS reduces clinically driven target lesion revascularization for patients with femoropopliteal in-stent restenosis. PMID:29265002

  19. Laparoscopic-guided abdominal wall nerve blocks in the pediatric population: a novel technique with comparison to ultrasound-guided blocks and local wound infiltration alone.

    PubMed

    Landmann, Alessandra; Visoiu, Mihaela; Malek, Marcus M

    2018-03-01

    Abdominal wall nerve blocks have been gaining popularity for the treatment of perioperative pain in children. Our aim was to compare a technique of surgeon-performed, laparoscopic abdominal wall nerve blocks to anesthesia-placed, ultrasound-guided abdominal wall nerve blocks and the current standard of local wound infiltration. After institutional review board approval was obtained, a retrospective chart review was performed of pediatric patients treated at a single institution during a 2-year period. Statistics were calculated using analysis of variance with post-hoc Bonferonni t tests for pair-wise comparisons. Included in this study were 380 patients who received ultrasound-guided abdominal wall nerve blocks (n = 125), laparoscopic-guided abdominal wall nerve blocks (n = 88), and local wound infiltration (n = 117). Groups were well matched for age, sex, and weight. There was no significant difference in pain scores within the first 8 hours or narcotic usage between groups. Local wound infiltration demonstrated the shortest overall time required to perform (P < .0001). Patients who received a surgeon-performed abdominal wall nerve block demonstrated a shorter duration of hospital stay when compared to the other groups (P = .02). Our study has demonstrated that laparoscopic-guided abdominal wall nerve blocks show similar efficacy to ultrasound-guided nerve blocks performed by pain management physicians without increasing time in the operating room. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Ultrasound-guided interventional procedures around the shoulder.

    PubMed

    Messina, Carmelo; Banfi, Giuseppe; Orlandi, Davide; Lacelli, Francesca; Serafini, Giovanni; Mauri, Giovanni; Secchi, Francesco; Silvestri, Enzo; Sconfienza, Luca Maria

    2016-01-01

    Ultrasound is an established modality for shoulder evaluation, being accurate, low cost and radiation free. Different pathological conditions can be diagnosed using ultrasound and can be treated using ultrasound guidance, such as degenerative, traumatic or inflammatory diseases. Subacromial-subdeltoid bursitis is the most common finding on ultrasound evaluation for painful shoulder. Therapeutic injections of corticosteroids are helpful to reduce inflammation and pain. Calcific tendinopathy of rotator cuff affects up to 20% of painful shoulders. Ultrasound-guided treatment may be performed with both single- and double-needle approach. Calcific enthesopathy, a peculiar form of degenerative tendinopathy, is a common and mostly asymptomatic ultrasound finding; dry needling has been proposed in symptomatic patients. An alternative is represented by autologous platelet-rich plasma injections. Intra-articular injections of the shoulder can be performed in the treatment of a variety of inflammatory and degenerative diseases with corticosteroids or hyaluronic acid respectively. Steroid injections around the long head of the biceps brachii tendon are indicated in patients with biceps tendinopathy, reducing pain and humeral tenderness. The most common indication for acromion-clavicular joint injection is degenerative osteoarthritis, with ultrasound representing a useful tool in localizing the joint space and properly injecting various types of drugs (steroids, lidocaine or hyaluronic acid). Suprascapular nerve block is an approved treatment for chronic shoulder pain non-responsive to conventional treatments as well as candidate patients for shoulder arthroscopy. This review provides an overview of these different ultrasonography-guided procedures that can be performed around the shoulder.

  1. Adopting Ultrasound Guidance for Prone Percutaneous Nephrolithotomy: Evaluating the Learning Curve for the Experienced Surgeon

    PubMed Central

    Usawachintachit, Manint; Masic, Selma; Allen, Isabel E.; Li, Jianxing

    2016-01-01

    Abstract Objectives: To define the learning curve associated with adopting ultrasound guidance for prone percutaneous nephrolithotomy (PCNL) for the experienced surgeon. Methods: A prospective cohort study of consecutive patients undergoing PCNL with ultrasound guidance for renal tract access and dilation was performed. Clinical data reviewed included success in gaining renal access with ultrasound guidance, total fluoroscopic screening time, and radiation exposure dose. PCNL cases performed with fluoroscopic guidance matched for stone size served as control cases. Results: One hundred consecutive ultrasound-guided procedures performed by a single experienced endourologist were divided into five experience groups. Significant improvement in renal access success rate with ultrasound was seen after 20 cases (p < 0.05). Total fluoroscopic screening time, radiation exposure dose, and operative time were also statistically significantly improved over the study period. When compared with fluoroscopy-guided PCNL, significant decreases in total fluoroscopic screening time (33.4 ± 35.3 seconds vs 157.5 ± 84.9 seconds, p < 0.05) and radiation exposure (7.0 ± 8.7 mGy vs 47.8 ± 45.9 mGy, p < 0.05) were seen. No differences in complication rates were found. Conclusions: Ultrasound-guided renal access for PCNL can be performed effectively after 20 cases. Transition to the use of ultrasound will quickly reduce radiation exposure for patients and intraoperative personnel. PMID:27150671

  2. Examples of Radiation-Emitting Products

    MedlinePlus

    ... Ultrasonography • Doppler ultrasound • Color doppler ultrasound • Hyperthermia • Diathermy/physical therapy • Bone healing • Lithotripsy • Phacoemulsifier • Needle guide • Bone density measuring • Geriatric bath (ultrasound) • Hearing aid • Many scientific uses • Nondestructive ...

  3. Real-time ultrasound-guided spinal anesthesia using the SonixGPS ultrasound guidance system: a feasibility study.

    PubMed

    Niazi, A U; Chin, K J; Jin, R; Chan, V W

    2014-08-01

    Real-time ultrasound-guided neuraxial blockade remains a largely experimental technique. SonixGPS® is a new needle tracking system that displays needle tip position on the ultrasound screen. We investigated if this novel technology might aid performance of real-time ultrasound-guided spinal anesthesia. Twenty patients with body mass index < 35 kg/m(2) undergoing elective total joint arthroplasty under spinal anesthesia were recruited. Patients with previous back surgery and spinal abnormalities were excluded. Following a pre-procedural ultrasound scan, a 17G proprietary needle-sensor assembly was inserted in-plane to the transducer in four patients and out-of-plane in 16 patients. In both approaches, the trajectory of insertion was adjusted in real-time until the needle tip lay just superficial to the ligamentum flavum-dura mater complex. At this point, a 25G 120 mm Whitacre spinal needle was inserted through the 17G SonixGPS® needle. Successful dural puncture was confirmed by backflow of cerebrospinal fluid from the spinal needle. An overall success rate of 14/20 (70%) was seen with two failures (50%) and four failures (25%) in the in-plane and out-of-plane groups respectively. Dural puncture was successful on the first skin puncture in 71% of patients and in a single needle pass in 57% of patients. The median total procedure time was 16.4 and 11.1 min in the in-plane and out-of-plane groups respectively. The SonixGPS® system simplifies real-time ultrasound-guided spinal anesthesia to a large extent, especially the out-of-plane approach. Nevertheless, it remains a complex multi-step procedure that requires time, specialized equipment, and a working knowledge of spinal sonoanatomy. © 2014 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  4. Ultrasound-guided thoracenthesis: the V-point as a site for optimal drainage positioning.

    PubMed

    Zanforlin, A; Gavelli, G; Oboldi, D; Galletti, S

    2013-01-01

    In the latest years the use of lung ultrasound is increasing in the evaluation of pleural effusions, because it makes follow-up easier and drainage more efficient by providing guidance on the most appropriate sampling site. However, no standardized approach for ultrasound-guided thoracenthesis is actually available. To evaluate our usual ultrasonographic landmark as a possible standard site to perform thoracenthesis by assessing its value in terms of safety and efficiency (success at first attempt, drainage as complete as possible). Hospitalized patients with non organized pleural effusion underwent thoracenthesis after ultrasound evaluation. The point showing on ultrasound the maximum thickness of the effusion ("V-point") was chosen for drainage. 45 ultrasound guided thoracenthesis were performed in 12 months. In 22 cases there were no complications; 16 cases of cough, 2 cases of mild dyspnea without desaturation, 4 cases of mild pain; 2 cases of complications requiring medical intervention occurred. No case of pneumothorax related to the procedure was detected. In all cases drainage was successful on the first attempt. The collected values of maximum thickness at V-point (min 3.4 cm - max 15.3 cm) and drained fluid volume (min 70 ml - max 2000 ml) showed a significative correlation (p < 0.0001). When the thickness was greater or equal to 9.9 cm, drained volume was always more than 1000 ml. The measure of the maximum thickness at V-point provides high efficiency to ultrasound guided thoracentesis and allows to estimate the amount of fluid in the pleural cavity. It is also an easy parameter that makes the proposed method quick to learn and apply.  

  5. Ultrasound-guided approach for axillary brachial plexus, femoral nerve, and sciatic nerve blocks in dogs.

    PubMed

    Campoy, Luis; Bezuidenhout, Abraham J; Gleed, Robin D; Martin-Flores, Manuel; Raw, Robert M; Santare, Carrie L; Jay, Ariane R; Wang, Annie L

    2010-03-01

    To describe an ultrasound-guided technique and the anatomical basis for three clinically useful nerve blocks in dogs. Prospective experimental trial. Four hound-cross dogs aged 2 +/- 0 years (mean +/- SD) weighing 30 +/- 5 kg and four Beagles aged 2 +/- 0 years and weighing 8.5 +/- 0.5 kg. Axillary brachial plexus, femoral, and sciatic combined ultrasound/electrolocation-guided nerve blocks were performed sequentially and bilaterally using a lidocaine solution mixed with methylene blue. Sciatic nerve blocks were not performed in the hounds. After the blocks, the dogs were euthanatized and each relevant site dissected. Axillary brachial plexus block Landmark blood vessels and the roots of the brachial plexus were identified by ultrasound in all eight dogs. Anatomical examination confirmed the relationship between the four ventral nerve roots (C6, C7, C8, and T1) and the axillary vessels. Three roots (C7, C8, and T1) were adequately stained bilaterally in all dogs. Femoral nerve block Landmark blood vessels (femoral artery and femoral vein), the femoral and saphenous nerves and the medial portion of the rectus femoris muscle were identified by ultrasound in all dogs. Anatomical examination confirmed the relationship between the femoral vessels, femoral nerve, and the rectus femoris muscle. The femoral nerves were adequately stained bilaterally in all dogs. Sciatic nerve block. Ultrasound landmarks (semimembranosus muscle, the fascia of the biceps femoris muscle and the sciatic nerve) could be identified in all of the dogs. In the four Beagles, anatomical examination confirmed the relationship between the biceps femoris muscle, the semimembranosus muscle, and the sciatic nerve. In the Beagles, all but one of the sciatic nerves were stained adequately. Ultrasound-guided needle insertion is an accurate method for depositing local anesthetic for axillary brachial plexus, femoral, and sciatic nerve blocks.

  6. A Randomized Controlled Trial Evaluating the See, Tilt, Align, and Rotate (STAR) Maneuver on Skill Acquisition for Simulated Ultrasound-Guided Interventional Procedures.

    PubMed

    Lam, Nicholas C K; Fishburn, Steven J; Hammer, Angie R; Petersen, Timothy R; Gerstein, Neal S; Mariano, Edward R

    2015-06-01

    Achieving the best view of the needle and target anatomy when performing ultrasound-guided interventional procedures requires technical skill, which novices may find difficult to learn. We hypothesized that teaching novice performers to use 4 sequential steps (see, tilt, align, and rotate [STAR] method) to identify the needle under ultrasound guidance is more efficient than training with the commonly described probe movements of align, rotate, and tilt (ART). This study compared 2 instructional methods for transducer manipulation including alignment of a probe and needle by novices during a simulated ultrasound-guided nerve block. Right-handed volunteers between the ages of 18 and 55 years who had no previous ultrasound experience were recruited and randomized to 1 of 2 groups; one group was trained to troubleshoot misalignment with the ART method, and the other was trained with the new STAR maneuver. Participants performed the task, consisting of directing a needle in plane to 3 targets in a standardized gelatin phantom 3 times. The performance assessor and data analyst were blinded to group assignment. Thirty-five participants were recruited. The STAR group was able to complete the task more quickly (P < .001) and visualized the needle in a greater proportion of the procedure time (P = .004) compared to the ART group. All STAR participants were able to complete the task, whereas 41% of ART participants abandoned the task (P = .003). Novices are able to complete a simulated ultrasound-guided nerve block more quickly and efficiently when trained with the 4-step STAR maneuver compared to the ART method. © 2015 by the American Institute of Ultrasound in Medicine.

  7. New piezocrystal material in the development of a 96-element array transducer for MR-guided focused ultrasound surgery

    NASA Astrophysics Data System (ADS)

    Qiu, Zhen; Habeshaw, Roderick; Fortine, Julien; Huang, Zhihong; Démoré, Christine; Cochran, Sandy

    2012-11-01

    Piezocrystal materials have been recognized as having better performance than piezoelectric ceramics, and have thus been widely adopted in ultrasound imaging arrays. Although their behaviour is susceptible to temperature and pressure, their large electromechanical coupling coefficients and other excellent piezoelectric properties also offer the potential for further improvements in the efficiency of therapeutic ultrasound transducers. Furthermore, new piezocrystals with modified compositions have been developed recently to increase their tolerance to temperature and pressure. In this work, a prototype of faceted bowl transducer was designed and manufactured as a proof of concept to explore practical issues associated with adoption of piezocrystals for magnetic resonance imaging guided focused ultrasound surgery.

  8. [Ultrasound-guided rectus sheath block for upper abdominal surgery].

    PubMed

    Osaka, Yoshimune; Kashiwagi, Masanori; Nagatsuka, Yukio; Oosaku, Masayoshi; Hirose, Chikako

    2010-08-01

    Upper abdominal surgery leads to severe postoperative pain. Insufficient postoperative analgesia accompanies a high incidence of complications. Therefore, postoperative analgesia is very important. The epidural analgesia has many advantages. However it has a high risk of epidural hematoma in anticoagulated patients. Rectus sheath block provided safer and more reliable analgesia in recent years, by the development of ultrasound tools. We experienced two cases of the rectus sheath block in upper abdominal surgery under ultrasound guidance. Ultrasound guided rectus sheath block can reduce the risk of peritoneal puncture, bleeding, and other complications. Rectus sheath block is very effective to reduce postoperative pain in upper abdominal surgery as an alternative method to epidural anesthesia in anticoagulated patients.

  9. Ultrasound-Guided Forearm Nerve Blocks: A Novel Application for Pain Control in Adult Patients with Digit Injuries

    PubMed Central

    Patricia Javedani, Parisa; Amini, Albert

    2016-01-01

    Phalanx fractures and interphalangeal joint dislocations commonly present to the emergency department. Although these orthopedic injuries are not complex, the four-point digital block used for anesthesia during the reduction can be painful. Additionally, cases requiring prolonged manipulation or consultation for adequate reduction may require repeat blockade. This case series reports four patients presenting after mechanical injuries resulting in phalanx fracture or interphalangeal joint dislocations. These patients received an ultrasound-guided peripheral nerve block of the forearm with successful subsequent reduction. To our knowledge, use of ultrasound-guided peripheral nerve blocks of the forearm for anesthesia in reduction of upper extremity digit injuries in adult patients in the emergency department setting has not been described before. PMID:27555971

  10. Ultrasound-Guided Drainage of Supralevator Hematoma in a Hemodynamically Stable Patient.

    PubMed

    Mukhopadhyay, Debjani; Jennings, Paul E; Banerjee, Mamta; Gada, Ruta

    2015-12-01

    Paravaginal hematomas can be life-threatening. In patients with intact vaginal walls and perineum, they may pose a diagnostic and therapeutic challenge. Supralevator hematomas are much less common than infralevator hematomas. We present a case of puerperal hemorrhagic shock after a normal vaginal delivery in a low-risk parous woman resulting from an occult supralevator hematoma. Because the woman was hemodynamically unstable initially, she underwent a vaginal surgical drainage. A week later, the supravaginal hematoma reformed. At this time the patient was hemodynamically stable, and ultrasound-guided drainage was performed, which resulted in complete resolution of the hematoma within 10 days. In a clinically stable puerperal patient, ultrasound-guided drainage of a supralevator hematoma resulted in rapid and complete resolution of symptoms.

  11. A pitfall during endobronchial ultrasound-guided transbronchial forceps biopsy of the mediastinal lymph nodes.

    PubMed

    Krenke, Rafal; Korczynski, Piotr; Gorska, Katarzyna; Chazan, Ryszarda

    2014-03-01

    The high diagnostic yield and favorable safety profile of endobronchial ultrasound-guided transbronchial forceps biopsy of the mediastinal lymph nodes have been recently demonstrated. We report an unusual technical problem during endobronchial ultrasound-guided transbronchial forceps biopsy that could be a prerequisite for severe complications. A rupture of the steering band precluded closure of the forceps jaws opened in the subcarinal lymph node. A solution to the problem is presented, together with other procedure-related complications reported in the literature. The report emphasizes that a dysfunction of the forceps steering band can result in severe complications when it occurs during transbronchial sampling of mediastinal lesions. Copyright © 2014 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  12. Acute Calcific Bursitis After Ultrasound-Guided Percutaneous Barbotage of Rotator Cuff Calcific Tendinopathy: A Case Report.

    PubMed

    Kang, Bo-Sung; Lee, Seung Hak; Cho, Yung; Chung, Sun Gun

    2016-08-01

    Ultrasound-guided percutaneous barbotage is an effective treatment for rotator cuff calcific tendinopathy, providing rapid and substantial pain relief. We present the case of a 49-year-old woman with aggravated pain early after ultrasound-guided barbotage of a large calcific deposit in the supraspinatus tendon. Subsequent examination revealed a thick calcification spreading along the subacromial-subdeltoid bursa space, suggesting acute calcific bursitis complicated by barbotage. Additional barbotage alleviated her pain completely. Therefore, a high index of suspicion for acute calcific bursitis is required in patients with unresolved or aggravated pain after barbotage. Repeated barbotage could be effective for this condition. Copyright © 2016 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  13. Ultrasound-guided thrombin injection of genicular artery pseudoaneurysm.

    PubMed

    Rachakonda, Aditya; Qato, Khalil; Khaddash, Tamim; Carroccio, Alfio; Pamoukian, Vicken; Giangola, Gary

    2015-07-01

    Pseudoaneurysm is a rare complication after arthroscopic procedures involving the knee. A 38-year-old man presented 1 month after right-knee arthroscopy with a 2-cm pulsating mass on the medial side of the right knee. Duplex ultrasound evaluation revealed 2.5 × 2.1-cm pseudoaneurysm just distal to the patella with arterialized flow communicating with the inferior medial genicular artery. Ultrasound-guided thrombin injection was performed in an office setting, and the resolution of active flow within the pseudoaneurysm was confirmed with duplex ultrasonography. Copyright © 2015 Elsevier Inc. All rights reserved.

  14. Case report: ultrasound-guided continuous thoracic paravertebral block for outpatient acute pain management of multilevel unilateral rib fractures.

    PubMed

    Murata, Hiroaki; Salviz, Emine Aysu; Chen, Stephanie; Vandepitte, Catherine; Hadzic, Admir

    2013-01-01

    A 61-year-old man with multiple unilateral rib fractures (T3-T8) gained the ability to breathe deeply and to ambulate after ultrasound-guided continuous thoracic paravertebral block and was discharged home after being observed for 15 hours after the block. The ultrasound guidance was helpful in determining the site of rib fractures and the optimal level for catheter placement. This report also discusses the management of analgesia using continuous paravertebral block in an outpatient with trauma.

  15. Endoscopic ultrasonography guided drainage: Summary of consortium meeting, May 21, 2012, San Diego, California

    PubMed Central

    Kahaleh, Michel; Artifon, Everson LA; Perez-Miranda, Manuel; Gaidhane, Monica; Rondon, Carlos; Itoi, Takao; Giovannini, Marc

    2015-01-01

    Endoscopic retrograde cholangiopancreatography (ERCP) is the preferred procedure for biliary and pancreatic drainage. While ERCP is successful in about 95% of cases, a small subset of cases are unsuccessful due to altered anatomy, peri-ampullary pathology, or malignant obstruction. Endoscopic ultrasound-guided drainage is a promising technique for biliary, pancreatic and recently gallbladder decompression, which provides multiple advantages over percutaneous or surgical biliary drainage. Multiple retrospective and some prospective studies have shown endoscopic ultrasound-guided drainage to be safe and effective. Based on the currently reported literature, regardless of the approach, the cumulative success rate is 84%-93% with an overall complication rate of 16%-35%. endoscopic ultrasound-guided drainage seems a viable therapeutic modality for failed conventional drainage when performed by highly skilled advanced endoscopists at tertiary centers with expertise in both echo-endoscopy and therapeutic endoscopy PMID:25624708

  16. Endobronchial ultrasound-guided transbronchial needle aspiration of thyroid: Report of two cases and systematic review of literature

    PubMed Central

    Madan, Karan; Mittal, Saurabh; Hadda, Vijay; Jain, Deepali; Mohan, Anant; Guleria, Randeep

    2016-01-01

    Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a minimally invasive and safe technique for a sampling of mediastinal lesions. Indications for EBUS-TBNA have gradually expanded since its introduction. The usual approach to cytological sampling of the thyroid gland is percutaneous ultrasound-guided fine needle aspiration (US-FNA) performed under local anesthesia. US-FNA may be risky or not feasible in intrathoracic/substernal thyroid location. Feasibility of aspirating thyroid lesions with EBUS-TBNA has been occasionally reported. We report two patients wherein EBUS-TBNA was utilized for thyroid lesion aspiration and definitive diagnosis. We highlight the utility and safety of EBUS-TBNA in the evaluation of intrathoracic thyroid lesions wherein image-guided percutaneous aspiration may be risky/sometimes impossible to perform. A systematic review of literature has also been performed summarizing and discussing the issues pertaining to EBUS-TBNA of the thyroid gland. PMID:27891005

  17. Simulation and training of ultrasound supported anaesthesia: a low-cost approach

    NASA Astrophysics Data System (ADS)

    Schaaf, T.; Lamontain, M.; Hilpert, J.; Schilling, F.; Tolxdorff, T.

    2010-03-01

    The use of ultrasound imaging technology during techniques of peripheral nerve blockade offers several clinical benefits. Here we report on a new method to educate residents in ultrasound-guided regional anesthesia. The daily challenge for the anesthesiologists is the 3D angle-depending handling of the stimulation needle and the ultrasound probe while watching the 2D ultrasound image on the monitor. Purpose: Our approach describes how a computer-aided simulation and training set for ultrasound-guided regional anesthesia could be built based on wireless low-cost devices and an interactive simulation of a 2D ultrasound image. For training purposes the injection needle and the ultrasound probe are replaced by wireless Bluetooth-connected 3D tracking devices, which are embedded in WII-mote controllers (Nintendo-Brand). In correlation to the tracked 3D positions of the needle and transducer models the visibility and position of the needle should be simulated in the 2D generated ultrasound image. Conclusion: In future, this tracking and visualization software module could be integrated in a more complex training set, where complex injection paths could be trained based on a 3D segmented model and the training results could be part of a curricular e-learning module.

  18. Internal Medicine Point-of-Care Ultrasound Curriculum: Consensus Recommendations from the Canadian Internal Medicine Ultrasound (CIMUS) Group.

    PubMed

    Ma, Irene W Y; Arishenkoff, Shane; Wiseman, Jeffrey; Desy, Janeve; Ailon, Jonathan; Martin, Leslie; Otremba, Mirek; Halman, Samantha; Willemot, Patrick; Blouw, Marcus

    2017-09-01

    Bedside point-of-care ultrasound (POCUS) is increasingly used to assess medical patients. At present, no consensus exists for what POCUS curriculum is appropriate for internal medicine residency training programs. This document details the consensus-based recommendations by the Canadian Internal Medicine Ultrasound (CIMUS) group, comprising 39 members, representing 14 institutions across Canada. Guiding principles for selecting curricular content were determined a priori. Consensus was defined as agreement by at least 80% of the members on POCUS applications deemed appropriate for teaching and assessment of trainees in the core (internal medicine postgraduate years [PGY] 1-3) and expanded (general internal medicine PGY 4-5) training programs. We recommend four POCUS applications for the core PGY 1-3 curriculum (inferior vena cava, lung B lines, pleural effusion, and abdominal free fluid) and three ultrasound-guided procedures (central venous catheterization, thoracentesis, and paracentesis). For the expanded PGY 4-5 curriculum, we recommend an additional seven applications (internal jugular vein, lung consolidation, pneumothorax, knee effusion, gross left ventricular systolic function, pericardial effusion, and right ventricular strain) and four ultrasound-guided procedures (knee arthrocentesis, arterial line insertion, arterial blood gas sampling, and peripheral venous catheterization). These recommendations will provide a framework for training programs at a national level.

  19. Palpation- and ultrasound-guided brachial plexus blockade in Hispaniolan Amazon parrots (Amazona ventralis).

    PubMed

    da Cunha, Anderson F; Strain, George M; Rademacher, Nathalie; Schnellbacher, Rodney; Tully, Thomas N

    2013-01-01

    To compare palpation-guided with ultrasound-guided brachial plexus blockade in Hispaniolan Amazon parrots. Prospective randomized experimental trial. Eighteen adult Hispaniolan Amazon parrots (Amazona ventralis) weighing 252-295 g. After induction of anesthesia with isoflurane, parrots received an injection of lidocaine (2 mg kg(-1)) in a total volume of 0.3 mL at the axillary region. The birds were randomly assigned to equal groups using either palpation or ultrasound as a guide for the brachial plexus block. Nerve evoked muscle potentials (NEMP) were used to monitor effectiveness of brachial plexus block. The palpation-guided group received the local anesthetic at the space between the pectoral muscle, triceps, and supracoracoideus aticimus muscle, at the insertion of the tendons of the caudal coracobrachial muscle, and the caudal scapulohumeral muscle. For the ultrasound-guided group, the brachial plexus and the adjacent vessels were located with B-mode ultrasonography using a 7-15 MHz linear probe. After location, an 8-5 MHz convex transducer was used to guide injections. General anesthesia was discontinued 20 minutes after lidocaine injection and the birds recovered in a padded cage. Both techniques decreased the amplitude of NEMP. Statistically significant differences in NEMP amplitudes, were observed within the ultrasound-guided group at 5, 10, 15, and 20 minutes after injection and within the palpation-guided group at 10, 15, and 20 minutes after injection. There was no statistically significant difference between the two groups. No effect on motor function, muscle relaxation or wing droop was observed after brachial plexus block. The onset of the brachial plexus block tended to be faster when ultrasonography was used. Brachial plexus injection can be performed in Hispaniolan Amazon parrots and nerve evoked muscle potentials were useful to monitor the effects on nerve conduction in this avian species. Neither technique produced an effective block at the doses of lidocaine used and further study is necessary to develop a useful block for surgical analgesia. © Published 2012. This article is a U.S. Government work and is in the public domain in the USA.

  20. Casualty Evacuation in the Contemporary Operating Environment

    DTIC Science & Technology

    2002-05-20

    HIFU ), or Focused Ultrasound ( FUS ), can be used to rapidly kill tissue (directly applicable to cancer treatment, for example) and to stop internal...132 Peter Kaczkowski, Development of a High-Intensity Focused Ultrasound System for Image-guided Ultrasound Surgery...spatial dimension, with acquisition and display occurring nearly in real time.135 Recent research has shown that High Intensity Focused Ultrasound

  1. Treatment of Partial Rotator Cuff Tear with Ultrasound-guided Platelet-rich Plasma.

    PubMed

    Sengodan, Vetrivel Chezian; Kurian, Sajith; Ramasamy, Raghupathy

    2017-01-01

    The treatment of symptomatic partial rotator cuff tear has presented substantial challenge to orthopaedic surgeons as it can vary from conservative to surgical repair. Researches have established the influence of platelet rich plasma in healing damaged tissue. Currently very few data are available regarding the evidence of clinical and radiological outcome of partial rotator cuff tear treated with ultrasound guided platelet rich plasma injection in English literature. 20 patients with symptomatic partial rotator cuff tears were treated with ultrasound guided platelet rich plasma injection. Before and after the injection of platelet rich plasma scoring was done with visual analogue score, Constant shoulder score, and UCLA shoulder score at 8 weeks and third month. A review ultrasound was performed 8 weeks after platelet rich plasma injection to assess the rotator cuff status. Our study showed statistically significant improvements in 17 patients in VAS pain score, constant shoulder score and UCLA shoulder score. No significant changes in ROM were noted when matched to the contra-lateral side ( P < 0.001) at the 3 month follow-up. The study also showed good healing on radiological evaluation with ultrasonogram 8 weeks after platelet rich plasma injection. Ultrasound guided platelet rich plasma injection for partial rotator cuff tears is an effective procedure that leads to significant decrease in pain, improvement in shoulder functions, much cost-effective and less problematic compared to a surgical treatment.

  2. Value of cytopathologist-performed ultrasound-guided fine-needle aspiration as a screening test for ultrasound-guided core-needle biopsy in nonpalpable breast masses.

    PubMed

    Lieu, David

    2009-04-01

    Fine-needle aspiration (FNA) of breast masses in the United States has been on the decline for the last decade and has been largely replaced by ultrasound-guided core-needle biopsy (UG-CNB). Some studies show core-needle biopsy (CNB) is superior to FNA in terms of absolute sensitivity, specificity, and inadequate rate. However, the importance of a skilled aspirator, experienced cytopathologist, and immediate cytological evaluation (ICE) in FNA is often not considered. CNB is more expensive, invasive, risky, and painful than FNA. This prospective study examines the value of cytopathologist-performed ultrasound-guided FNA (UG-FNA) with ICE as a screening test for cytopathologist-performed UG-CNB on nonpalpable or difficult-to-palpate solid breast masses visible on ultrasound. One hundred twenty consecutive nonpalpable or difficult-to-palpate presumably solid breast masses in 109 female patients from January2, 2008 to June 30, 2008 underwent cytopathologist-performed UG-FNA with ICE. Twenty cases were converted to cytopathologist-performed UG-CNB because ICE was inadequate, hypocellular, atypical, suspicious, or malignant. Patients with clearly benign cytology did not undergo UG-CNB. UG-FNA with ICE reduced the percentage of patients undergoing UG-CNB by 87%. A new role for cytopathologist-performed UG-FNA of nonpalpable breast masses has been identified.

  3. Comparison of ultrasound-guided supraclavicular block according to the various volumes of local anesthetic

    PubMed Central

    Kim, Seok Kon; Kang, Bong Jin; Kwon, Min A; Song, Jae Gyok; Jeon, Soo Mi

    2013-01-01

    Background The ultrasound guidance in regional nerve blocks has recently been introduced and gaining popularity. Ultrasound-guided supraclavicular block has many advantages including the higher success rate, faster onset time, and fewer complications. The aim of this study was to examine the clinical data according to the varied volume of local anesthetics in the ultrasound-guided supraclavicular block. Methods One hundred twenty patients were randomized into four groups, according to the local anesthetic volume used: Group 35 (n = 30), Group 30 (n = 30), Group 25 (n = 30), and Group 20 (n = 30). Supraclavicular blocks were performed with 1% mepivacaine 35 ml, 30 ml, 25 ml, and 20 ml, respectively. The success rate, onset time, and complications were checked and evaluated. Results The success rate (66.7%) was lower in Group 20 than that of Group 35 (96.7%) (P < 0.05). The average onset times of Group 35, Group 30, Group 25, and Group 20 were 14.3 ± 6.9 min, 13.6 ± 4.5 min, 16.7 ± 4.6 min, and 16.5 ± 3.7 min, respectively. There were no significant differences. Horner's syndrome was higher in Group 35 (P < 0.05). Conclusions In conclusion, we achieved 90% success rate with 30 ml of 1% mepivacaine. Therefore, we suggest 30 ml of local anesthetic volume for ultrasound-guided supraclavicular block. PMID:23814648

  4. Medical Ultrasound Technology Research and Development at the University of Washington Center for Industrial and Medical Ultrasound

    DTIC Science & Technology

    2003-10-02

    provide a world-class, advanced research center for bioengineering development and graduate education in high-intensity, focused ultrasound ( HIFU ). This...convenient, and robust. These technological enhancements have enabled the development of HIFU arrays and image-guided ultrasound systems for greater... Ultrasound (CIMU). The many disparate facilities and technical capabilities available to CIMU staff and students were integrated and enhanced to

  5. Fiber optic photoacoustic probe with ultrasonic tracking for guiding minimally invasive procedures

    NASA Astrophysics Data System (ADS)

    Xia, Wenfeng; Mosse, Charles A.; Colchester, Richard J.; Mari, Jean Martial; Nikitichev, Daniil I.; West, Simeon J.; Ourselin, Sebastien; Beard, Paul C.; Desjardins, Adrien E.

    2015-07-01

    In a wide range of clinical procedures, accurate placement of medical devices such as needles and catheters is critical to optimize patient outcomes. Ultrasound imaging is often used to guide minimally invasive procedures, as it can provide real-time visualization of patient anatomy and medical devices. However, this modality can provide low image contrast for soft tissues, and poor visualization of medical devices that are steeply angled with respect to the incoming ultrasound beams. Photoacoustic sensors can provide information about the spatial distributions of tissue chromophores that could be valuable for guiding minimally invasive procedures. In this study, a system for guiding minimally invasive procedures using photoacoustic sensing was developed. This system included a miniature photoacoustic probe with three optical fibers: one with a bare end for photoacoustic excitation of tissue, a second for photoacoustic excitation of an optically absorbing coating at the distal end to transmit ultrasound, and a third with a Fabry-Perot cavity at the distal end for receiving ultrasound. The position of the photoacoustic probe was determined with ultrasonic tracking, which involved transmitting pulses from a linear-array ultrasound imaging probe at the tissue surface, and receiving them with the fiber-optic ultrasound receiver in the photoacoustic probe. The axial resolution of photoacoustic sensing was better than 70 μm, and the tracking accuracy was better than 1 mm in both axial and lateral dimensions. By translating the photoacoustic probe, depth scans were obtained from different spatial positions, and two-dimensional images were reconstructed using a frequency-domain algorithm.

  6. Feasibility of ultrasound-guided epidural access at the lumbo-sacral space in dogs.

    PubMed

    Liotta, Annalisa; Busoni, Valeria; Carrozzo, Maria Valentina; Sandersen, Charlotte; Gabriel, Annick; Bolen, Géraldine

    2015-01-01

    Epidural injections are commonly performed blindly in veterinary medicine. The aims of this study were to describe the lumbosacral ultrasonographic anatomy and to assess the feasibility of an ultrasound-guided epidural injection technique in dogs. A cross sectional anatomic atlas of the lumbosacral region and ex vivo ultrasound images were obtained in two cadavers to describe the ultrasound anatomy and to identify the landmarks. Sixteen normal weight canine cadavers were used to establish two variations of the technique for direct ultrasound-guided injection, using spinal needles or epidural catheters. The technique was finally performed in two normal weight cadavers, in two overweight cadavers and in five live dogs with radiographic abnormalities resulting of the lumbosacral spine. Contrast medium was injected and CT was used to assess the success of the injection. The anatomic landmarks to carry out the procedure were the seventh lumbar vertebra, the iliac wings, and the first sacral vertebra. The target for directing the needle was the trapezoid-shaped echogenic zone between the contiguous articular facets of the lumbosacral vertebral canal visualized in a parasagittal plane. The spinal needle or epidural catheter was inserted in a 45° craniodorsal-caudoventral direction through the subcutaneous tissue and the interarcuate ligament until reaching the epidural space. CT examination confirmed the presence of contrast medium in the epidural space in 25/25 dogs, although a variable contamination of the subarachnoid space was also noted. Findings indicated that this ultrasound-guided epidural injection technique is feasible for normal weight and overweight dogs, with and without radiographic abnormalities of the spine. © 2014 American College of Veterinary Radiology.

  7. Long-term follow-up of ultrasound-guided botulinum toxin-A injections for sialorrhea in neurological dysphagia.

    PubMed

    Barbero, Pierangelo; Busso, Marco; Tinivella, Marco; Artusi, Carlo Alberto; De Mercanti, Stefania; Cucci, Angele; Veltri, Andrea; Avagnina, Paolo; Calvo, Andrea; Chio', Adriano; Durelli, Luca; Clerico, Marinella

    2015-12-01

    Literature provides reports only of a limited follow-up single injection of botulinum toxin-A (BoNT-A) in patients with sialorrhea. The aim of our study is to evaluate the long-lasting efficacy and safety of ultrasound-guided BoNT-A injections for severe sialorrhea secondary to neurological dysphagia. We enrolled 38 severe adult sialorrhea patients referred consecutively to the neurology unit and performed bilateral parotid and submandibular gland BoNT-A injections under ultrasound guidance. The outcomes of the study were reduction of sialorrhea, duration of therapeutic effect, and subjective patient- and caregiver-reported satisfaction. A total of 113 BoNT-A administrations were given during the study period with a mean duration of follow-up of 20.2 ± 4.4 months. We observed a significant decrease from baseline in mean number of daily aspirations and a significant improvement in patient- and caregiver-reported outcomes following ultrasound-guided BoNT-A injections (p < 0.001 vs baseline for all comparisons) and the mean duration of the efficacy was 5.6 ± 1 months. No major treatment-related adverse events occurred and a low incidence of minor adverse events was reported. This study confirms the long-lasting efficacy and safety of ultrasound-guided BoNT-A injections for sialorrhea, regardless of the causative neurological disorder. These results should encourage the use of BoNT-A in the treatment of severe sialorrhea and highlight the role of ultrasound guidance to obtain optimal results in terms of safety and reproducible outcomes.

  8. Ultrasound-guided, percutaneous peripheral nerve stimulation: technical note.

    PubMed

    Chan, Isaac; Brown, Anthony R; Park, Kenneth; Winfree, Christopher J

    2010-09-01

    Peripheral nerve stimulation is a form of neuromodulation that applies electric current to peripheral nerves to induce stimulation paresthesias within the painful areas. To report a method of ultrasound-guided, percutaneous peripheral nerve stimulation. This technique utilizes real-time imaging to avoid injury to adjacent vascular structures during minimally invasive placement of peripheral nerve stimulator electrodes. We describe a patient that presented with chronic, bilateral foot pain following multiple foot surgeries, for whom a comprehensive, pain management treatment strategy had failed. We utilized ultrasound-guided, percutaneous tibial nerve stimulation at a thigh level to provide durable pain relief on the right side, and open peripheral nerve stimulation on the left. The patient experienced appropriate stimulation paresthesias and excellent pain relief on the plantar aspect of the right foot with the percutaneous electrode. On the left side, we were unable to direct the stimulation paresthesias to the sole of the foot, despite multiple electrode repositionings. A subsequent, open placement of a left tibial nerve stimulator was performed. This revealed that the correct electrode position against the tibial nerve was immediately adjacent to the popliteal artery, and was thus not appropriate for percutaneous placement. We describe a method of ultrasound-guided peripheral nerve stimulation that avoids the invasiveness of electrode placement via an open procedure while providing excellent pain relief. We further describe limitations of the percutaneous approach when navigating close to large blood vessels, a situation more appropriately managed with open peripheral nerve stimulator placement. Ultrasound-guided placement may be considered for patients receiving peripheral nerve stimulators placed within the deep tissues, and not easily placed in a blind fashion.

  9. [Assessment of amylase and lipase levels following puncture biopsy and fine needle aspiration guided by endoscopic ultrasound in pancreatic lesions].

    PubMed

    Membrillo-Romero, Alejandro; Gonzalez-Lanzagorta, Rubén; Rascón-Martínez, Dulce María

    Puncture biopsy and fine needle aspiration guided by endoscopic ultrasound has been used as an effective technique and is quickly becoming the procedure of choice for diagnosis and staging in patients suspected of having pancreatic cancer. This procedure has replaced retrograde cholangiopancreatography and brush cytology due to its higher sensitivity for diagnosis, and lower risk of complications. To assess the levels of pancreatic enzymes amylase and lipase, after the puncture biopsy and fine needle aspiration guided by endoscopic ultrasound in pancreatic lesions and the frequency of post-puncture acute pancreatitis. A longitudinal and descriptive study of consecutive cases was performed on outpatients submitted to puncture biopsy and fine needle aspiration guided by endoscopic ultrasound in pancreatic lesions. Levels of pancreatic enzymes such as amylase and lipase were measured before and after the pancreatic puncture. Finally we documented post-puncture pancreatitis cases. A total of 100 patients who had been diagnosed with solid and cystic lesions were included in the study. Significant elevation was found at twice the reference value for lipase in 5 cases (5%) and for amylase in 2 cases (2%), none had clinical symptoms of acute pancreatitis. Eight (8%) of patients presented with mild nonspecific pain with no enzyme elevation compatible with pancreatitis. Pancreatic biopsy needle aspiration guided by endoscopic ultrasound was associated with a low rate of elevated pancreatic enzymes and there were no cases of post-puncture pancreatitis. Copyright © 2016 Academia Mexicana de Cirugía A.C. Publicado por Masson Doyma México S.A. All rights reserved.

  10. Safety of Ultrasound-Guided Botulinum Toxin Injections for Sialorrhea as Performed by Pediatric Otolaryngologists.

    PubMed

    Shariat-Madar, Bahbak; Chun, Robert H; Sulman, Cecille G; Conley, Stephen F

    2016-05-01

    To evaluate incidence of complications and hospital readmission as a result of ultrasound-guided botulinum toxin injections to manage sialorrhea. Case series with chart review. Children's Hospital of Wisconsin. A case series with chart review was performed of all cases of ultrasound-guided injection of botulinum toxin by pediatric otolaryngologists from March 5, 2010, to September 26, 2014,. Primary outcomes included complications such as dysphagia, aspiration pneumonia, and motor paralysis. Secondary outcomes included hospitalization, intubation, and nasogastric tube placement. There were 48 patients, 111 interventions, and 306 intraglandular injections identified. Botulinum toxin type A and type B were utilized in 4 and 107 operative interventions, respectively. Type A was injected into 4 parotid and 4 submandibular glands, utilizing doses of 20 U per parotid and 30 U per submandibular gland. Type B was injected into 98 parotid and 200 submandibular glands, with average dosing of 923 U per parotid and 1170 U per submandibular gland, respectively. There were 2 instances of subjectively worsening of baseline dysphagia that self-resolved. No cases were complicated by aspiration pneumonia or motor paralysis. No patients required hospital readmission, intubation, or nasogastric tube placement. Prior published data indicated 16% complication incidence with ultrasound-guided injection of botulinum toxin. Our study found a low complication rate (0.6%) with ultrasound-guided injections of botulinum toxin to manage sialorrhea, without cases of aspiration pneumonia or motor paralysis. Of 306 intraglandular injections, there were 2 cases of worsening baseline subjective dysphagia that self-resolved. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2016.

  11. Ultrasound as a Screening Tool for Central Venous Catheter Positioning and Exclusion of Pneumothorax.

    PubMed

    Amir, Rabia; Knio, Ziyad O; Mahmood, Feroze; Oren-Grinberg, Achikam; Leibowitz, Akiva; Bose, Ruma; Shaefi, Shahzad; Mitchell, John D; Ahmed, Muneeb; Bardia, Amit; Talmor, Daniel; Matyal, Robina

    2017-07-01

    Although real-time ultrasound guidance during central venous catheter insertion has become a standard of care, postinsertion chest radiograph remains the gold standard to confirm central venous catheter tip position and rule out associated lung complications like pneumothorax. We hypothesize that a combination of transthoracic echocardiography and lung ultrasound is noninferior to chest radiograph when used to accurately assess central venous catheter positioning and screen for pneumothorax. All operating rooms and surgical and trauma ICUs at the institution. Single-center, prospective noninferiority study. Patients receiving ultrasound-guided subclavian or internal jugular central venous catheters. During ultrasound-guided central venous catheter placement, correct positioning of central venous catheter was accomplished by real-time visualization of the guide wire and positive right atrial swirl sign using the subcostal four-chamber view. After insertion, pneumothorax was ruled out by the presence of lung sliding and seashore sign on M-mode. Data analysis was done for 137 patients. Chest radiograph ruled out pneumothorax in 137 of 137 patients (100%). Lung ultrasound was performed in 123 of 137 patients and successfully screened for pneumothorax in 123 of 123 (100%). Chest radiograph approximated accurate catheter tip position in 136 of 137 patients (99.3%). Adequate subcostal four-chamber views could not be obtained in 13 patients. Accurate positioning of central venous catheter with ultrasound was then confirmed in 121 of 124 patients (97.6%) as described previously. Transthoracic echocardiography and lung ultrasound are noninferior to chest x-ray for screening of pneumothorax and accurate central venous catheter positioning. Thus, the point of care use of ultrasound can reduce central venous catheter insertion to use time, exposure to radiation, and improve patient safety.

  12. Feasibility of MRI-guided Focused Ultrasound as Organ-Sparing Treatment for Testicular Cancer

    NASA Astrophysics Data System (ADS)

    Staruch, Robert; Curiel, Laura; Chopra, Rajiv; Hynynen, Kullervo

    2009-04-01

    High cure rates for testicular cancer have prompted interest in organ-sparing surgery for patients with bilateral disease or single testis. Focused ultrasound (FUS) ablation could offer a noninvasive approach to organ-sparing surgery. The objective of this study was to determine the feasibility of using MR thermometry to guide organ-sparing focused ultrasound surgery in the testis. The testes of anesthetized rabbits were sonicated in several discrete locations using a single-element focused transducer operating at 2.787MHz. Focal heating was visualized with MR thermometry, using a measured PRF thermal coefficient of -0.0089±0.0003 ppm/° C. Sonications at 3.5-14 acoustic watts applied for 30 seconds produced maximum temperature elevations of 10-80° C, with coagulation verified by histology. Coagulation of precise volumes in the testicle is feasible with MRI-guided focused ultrasound. Variability in peak temperature for given sonication parameters suggests the need for online temperature feedback control.

  13. Photoacoustic-guided ultrasound therapy with a dual-mode ultrasound array

    NASA Astrophysics Data System (ADS)

    Prost, Amaury; Funke, Arik; Tanter, Mickaël; Aubry, Jean-François; Bossy, Emmanuel

    2012-06-01

    Photoacoustics has recently been proposed as a potential method to guide and/or monitor therapy based on high-intensity focused ultrasound (HIFU). We experimentally demonstrate the creation of a HIFU lesion at the location of an optical absorber, by use of photoacoustic signals emitted by the absorber detected on a dual mode transducer array. To do so, a dedicated ultrasound array intended to both detect photoacoustic waves and emit HIFU with the same elements was used. Such a dual-mode array provides automatically coregistered reference frames for photoacoustic detection and HIFU emission, a highly desired feature for methods involving guidance or monitoring of HIFU by use of photoacoustics. The prototype is first characterized in terms of both photoacoustic and HIFU performances. The probe is then used to perform an idealized scenario of photoacoustic-guided therapy, where photoacoustic signals generated by an absorbing thread embedded in a piece of chicken breast are used to automatically refocus a HIFU beam with a time-reversal mirror and necrose the tissue at the location of the absorber.

  14. Comparing the effectiveness of ropivacaine 0.5% versus ropivacaine 0.2% for transabdominis plane block in providing postoperative analgesia after appendectomy.

    PubMed

    Abdul Jalil, Reymi Marseela; Yahya, Nurlia; Sulaiman, Omar; Wan Mat, Wan Rahiza; Teo, Rufinah; Izaham, Azarinah; Rahman, Raha Abdul

    2014-06-01

    The basis for the transversus abdominis plane (TAP) block involves infiltration of a local anesthetic into the neurofascial plane between the internal oblique and the transversus abdominis muscles, causing a regional block that spreads between the L1 and T10 dermatomes. Thus, the TAP block is said to be suitable for lower abdominal surgery. This study was designed to compare the analgesic efficacy of two different concentrations of ropivacaine for TAP block in patients undergoing appendectomy. Fifty-six patients with American Society of Anesthesiologists physical status I or II, aged 18 years and above, undergoing appendectomy were recruited in this prospective, randomized, double-blind study. They were divided into two groups: Group A patients who received 0.5 mL/kg of ropivacaine 0.5% and Group B patients who received 0.5 mL/kg of ropivacaine 0.2% via TAP block under ultrasound guidance. Postoperative pain was assessed using the visual analog scale upon arrival at the recovery room in the operating theatre, just prior to being discharged to the ward, and at 6 hours, 12 hours, 18 hours, and 24 hours postoperatively to compare the effectiveness of analgesia. Intraoperatively, patients in Group B required a significantly greater amount of additional intravenous fentanyl than those in Group A. There were no significant statistical differences in pain scores at rest and on movement at all assessment times as well as in the dose of 24-hour intravenous morphine consumption given via patient-controlled analgesia postoperatively between the two groups. The effectiveness of two different concentrations of ropivacaine (0.5% versus 0.2%) given via TAP block was comparable in providing postoperative analgesia for patients undergoing appendectomy. Copyright © 2014. Published by Elsevier B.V.

  15. Can motor control training lower the risk of injury for professional football players?

    PubMed

    Hides, Julie A; Stanton, Warren R

    2014-04-01

    Among injuries reported by the Australian Football League (AFL), lower limb injuries have shown the highest incidence and prevalence rates. Deficits in the muscles of the lumbopelvic region, such as a smaller size of multifidus (MF) muscle, have been related to the occurrence of lower limb injuries in the preseason in AFL players. Motor control training programs have been effective in restoring the size and control of the MF muscle, but the relationship between motor control training and occurrence of injuries has not been extensively examined. This pre- and postintervention trial was delivered during the playing season as a panel design with three groups. The motor control program involved voluntary contractions of the MF, transversus abdominis, and pelvic floor muscles while receiving feedback from ultrasound imaging and progressed into a functional rehabilitation program. Assessments of muscle size and function were performed using magnetic resonance imaging and included the measurement of cross-sectional areas of MF, psoas, and quadratus lumborum muscles and the change in trunk cross-sectional area due to voluntarily contracting the transversus abdominis muscle. Injury data were obtained from club records. Informed consent was obtained from all study participants. A smaller size of the MF muscle (odds ratio [OR] = 2.38) or quadratus lumborum muscle (OR = 2.17) was predictive of lower limb injury in the playing season. At the time point when one group of players had not received the intervention (n = 14), comparisons were made with the combined groups who had received the intervention (n = 32). The risk of sustaining a severe injury was lower for those players who received the motor control intervention (OR = 0.09). Although there are many factors associated with injuries in AFL, motor control training may provide a useful addition to strategies aimed at reducing lower limb injuries.

  16. "Transversus Abdominis Plane Blocks in Microsurgical Breast Reconstruction: Analysis of Pain, Narcotic Consumption, Length of Stay and Cost."

    PubMed

    Salibian, Ara A; Frey, Jordan D; Thanik, Vishal D; Karp, Nolan S; Choi, Mihye

    2018-06-02

    Transversus abdominis plane (TAP) blocks are increasingly being utilized in microvascular breast reconstruction. The implications of TAP blocks on specific reconstructive, patient and institutional outcomes remain to be fully elucidated. Patients undergoing abdominally-based microvascular breast reconstruction from 2015-2017 were reviewed. Length of stay, complications, narcotic consumption, donor-site pain and hospital expenses were compared between patients that did and those that did not receive TAP blocks with liposomal bupivacaine. Outcomes were subsequently compared in patients with elevated body mass index (BMI). Fifty patients (43.9%) received TAP blocks (27 [54.0%] under ultrasound guidance) and 64 patients (56.1%) did not. Patients with TAP blocks had significantly decreased oral and total narcotic consumption (p=0.0001 and p<0.0001, respectively) as well as significantly less donor-site pain (3.3 versus 4.3, p<0.0001). There was no significant difference in hospital expenses between the two cohorts ($21,531.53 versus $22,050.15 per patient, p=0.5659). Patients with BMI≥25 who received TAP blocks had a significantly decreased length of stay (3.8 versus 4.4 days, p=0.0345) as well as decreased narcotic consumption and postoperative pain compared to patients without TAP blocks. Patients with BMI<25 did not have a significant difference in postoperative pain, narcotic consumption or length of stay between the TAP versus no TAP block groups. TAP blocks with liposomal bupivacaine significantly reduce oral and total postoperative narcotic consumption as well as donor-site pain in all patients after abdominally-based microvascular breast reconstruction without increasing hospital expenses. TAP blocks additionally significantly decrease length of stay in patients with BMI≥25.

  17. Focused Ultrasound Surgery in Oncology: Overview and Principles

    PubMed Central

    McDannold, Nathan J.; Hynynen, Kullervo; Jolesz, Ferenc A.

    2011-01-01

    Focused ultrasound surgery (FUS) is a noninvasive image-guided therapy and an alternative to surgical interventions. It presents an opportunity to revolutionize cancer therapy and to affect or change drug delivery of therapeutic agents in new focally targeted ways. In this article the background, principles, technical devices, and clinical cancer applications of image-guided FUS are reviewed. © RSNA, 2011 PMID:21436096

  18. Ultrasound-guided fine needle aspiration in the diagnosis of peripheral nerve sheath tumors in 4 dogs

    PubMed Central

    da Costa, Ronaldo C.; Parent, Joane M.; Dobson, Howard; Ruotsalo, Kristiina; Holmberg, David; Duque, M. Carolina; Poma, Roberto

    2008-01-01

    Ultrasound-guided fine needle aspiration was used in establishing the diagnosis in 4 cases of malignant peripheral nerve sheath tumor. Sonographic and cytologic characteristics are discussed. Because of its availability and ease of use, axillary ultrasonography with fine needle aspiration can be an initial diagnostic step for suspected brachial plexus tumors. PMID:18320983

  19. Value of Artisanal Simulators to Teach Ultrasound-Guided Percutaneous Biopsy Using a Tru-Cut Needle for Veterinary and Medical Students

    ERIC Educational Resources Information Center

    de Araújo Setin, Raíza; Fortes Cirimbelli, Carolina; Mazeto Ercolin, Anna Carolina; Pires, Sâmara Turbay; Disselli, Tamiris; Ferrarini Nunes Soares Hage, Maria Cristina

    2018-01-01

    The present study aimed to evaluate the applicability of artisanal simulators to teach veterinary and medical students the ultrasound-guided percutaneous biopsy using a tru-cut needle. The artisanal simulators consisted of bovine liver between two layers of commercially available grape gelatin. Students were paired, with one doing the biopsy and…

  20. Ultrasound guided electrical impedance tomography for 2D free-interface reconstruction

    NASA Astrophysics Data System (ADS)

    Liang, Guanghui; Ren, Shangjie; Dong, Feng

    2017-07-01

    The free-interface detection problem is normally seen in industrial or biological processes. Electrical impedance tomography (EIT) is a non-invasive technique with advantages of high-speed and low cost, and is a promising solution for free-interface detection problems. However, due to the ill-posed and nonlinear characteristics, the spatial resolution of EIT is low. To deal with the issue, an ultrasound guided EIT is proposed to directly reconstruct the geometric configuration of the target free-interface. In the method, the position of the central point of the target interface is measured by a pair of ultrasound transducers mounted at the opposite side of the objective domain, and then the position measurement is used as the prior information for guiding the EIT-based free-interface reconstruction. During the process, a constrained least squares framework is used to fuse the information from different measurement modalities, and the Lagrange multiplier-based Levenberg-Marquardt method is adopted to provide the iterative solution of the constraint optimization problem. The numerical results show that the proposed ultrasound guided EIT method for the free-interface reconstruction is more accurate than the single modality method, especially when the number of valid electrodes is limited.

  1. Ultrasound-guided injection of botulinum toxin A in the treatment of iliopsoas spasticity

    PubMed Central

    Sconfienza, L.M.; Perrone, N.; Lacelli, F.; Lentino, C.; Serafini, G.

    2008-01-01

    Purpose Intramuscular injection of botulinum toxin A (BTX-A) is a common treatment for iliopsoas muscle spasticity, but it is not easy to position the needle in this muscle without guidance. In this paper we describe an ultrasound-guided technique for the intramuscular injection of BTX-A to treat spasticity of the iliopsoas muscle. Its effectiveness was assessed in 10 patients. Method and materials The ultrasound-guided technique for BTX-A injection was used on 10 patients. The needle was inserted into the muscle belly at an angle of 45° along the longitudinal axis of the muscle when allowed by patient's condition. Results In all cases, the iliopsoas muscle was easily identified and both the iliac and psoas components were assessed. Introduction of the needle and drug injection were entirely carried out under ultrasonographic guidance. The procedure was successful in all patients, even in those with a high-grade spasticity, and general anesthesia was not required. Conclusions This ultrasound-guided technique allows accurate guidance for the injection of BTX-A, and it can be considered as an alternate supportive therapy in patients with spasticity and dystonia. PMID:23396653

  2. The Gross Morphology and Histochemistry of Respiratory Muscles in Bottlenose Dolphins, Tursiops truncatus

    PubMed Central

    Cotten, Pamela B.; Piscitelli, Marina A.; McLellan, William A.; Rommel, Sentiel A.; Dearolf, Jennifer L.; Pabst, D. Ann

    2011-01-01

    Most mammals possess stamina because their locomotor and respiratory (i.e., ventilatory) systems are mechanically coupled. These systems are decoupled, however, in bottlenose dolphins (Tursiops truncatus) as they swim on a breath-hold. Locomotion and ventilation are coupled only during their brief surfacing event, when they respire explosively (up to 90% of total lung volume in approximately 0.3s) (Ridgway et al., 1969). The predominantly slow-twitch fiber profile of their diaphragm (Dearolf, 2003) suggests that this muscle does not likely power their rapid ventilatory event. Based upon Bramble's (1989) biomechanical model of locomotor-respiratory coupling in galloping mammals, it was hypothesized that locomotor muscles function to power ventilation in bottlenose dolphins. It was further hypothesized that these muscles would be composed predominantly of fast-twitch fibers to facilitate the bottlenose dolphin's rapid ventilation. The gross morphology of cranio-cervical (scalenus, sternocephalicus, sternohyoid), thoracic (intercostals, transverse thoracis), and lumbo-pelvic (hypaxialis, rectus abdominis, abdominal obliques) muscles (n=7) and the fiber-type profiles (n=6) of selected muscles (scalenus, sternocephalicus, sternohyoid, rectus abdominis) of bottlenose dolphins were investigated. Physical manipulations of excised thoracic units were carried out to investigate potential actions of these muscles. Results suggest that the cranio-cervical muscles act to draw the sternum and associated ribs cranio-dorsally, which flares the ribs laterally, and increases the thoracic cavity volume required for inspiration. The lumbo-pelvic muscles act to draw the sternum and caudal ribs caudally, which decreases the volumes of the thoracic and abdominal cavities required for expiration. All muscles investigated were composed predominantly of fast-twitch fibers (range 61-88% by area) and appear histochemically poised for rapid contraction. These combined results suggest that dolphins utilize muscles, similar to those used by galloping mammals, to power their explosive ventilation. PMID:18777569

  3. Efficacy of transverse abdominis plane block in reduction of postoperation pain in laparoscopic cholecystectomy.

    PubMed

    Saliminia, Alireza; Azimaraghi, Omid; Babayipour, Shiva; Ardavan, Kamelia; Movafegh, Ali

    2015-12-01

    Transversus abdominis plane (TAP) block is a recently introduced regional anesthesia technique that is used for postoperative pain reduction in some abdominal surgeries. The present study evaluated the efficacy of the TAP block on the post laparoscopic cholecystectomy pain intensity and analgesic consumption. Fifty-four patients were enrolled in three groups: TAP block with normal saline (Group 1, n = 18); TAP block with bupivacaine (Group 2, n = 18); and TAP block with bupivacaine plus sufentanil (Group 3, n = 18). The time to the first fentanyl request, fentanyl consumption in the 24 hours following surgery, and postoperative pain intensity at 30 minutes, 1 hour, 6 hours, 12 hours, and 24 hours following discharge for recovery were measured and recorded. The total amount of 24-hour fentanyl consumption was higher in Group 1 (877.8 ± 338.8 μg) than either Group 2 (566.7 ± 367.8 μg) or Group 3 (555.5 ± 356.8 μg; p = 0.03). Postoperative pain score was higher in Group 1 than intervention groups (p = 0.006); however, there was no significant difference in intervention groups. The time to the first fentanyl request in Group 1 (79.44 ± 42.2) was significantly lower than Group 3 (206.38 ± 112.7; p = 0.001). The present study demonstrated that bilateral TAP block with 0.5% bupivacaine reduces post laparoscopic cholecystectomy pain intensity and fentanyl request and prolongs time to the first analgesic request. Adding sufentanil to the block solution reduced neither pain intensity nor fentanyl further consumption. Copyright © 2015. Published by Elsevier B.V.

  4. Mechanical property assessment of tissue-mimicking phantoms using remote palpation and optical read-out for amplitude of vibration and refractive index modulation.

    PubMed

    Usha Devi, C; Bharat Chandran, R S; Vasu, R Mohan; Sood, Ajay K

    2007-01-01

    A coherent light beam is used to interrogate the focal region within a tissue-mimicking phantom insonified by an ultrasound transducer. The ultrasound-tagged photons exiting from the object carry with them information on local optical path length fluctuations caused by refractive index variations and medium vibration. Through estimation of the force distribution in the focal region of the ultrasound transducer, and solving the forward elastography problem for amplitude of vibration of tissue particles, we observe that the amplitude is directed along the axis of the transducer. It is shown that the focal region interrogated by photons launched along the transducer axis carries phase fluctuations owing to both refractive index variations and particle vibration, whereas the photons launched perpendicular to the transducer axis carry phase fluctuations arising mainly from the refractive index variations, with only smaller contribution from vibration of particles. Monte-Carlo simulations and experiments done on tissue-mimicking phantoms prove that as the storage modulus of the phantom is increased, the detected modulation depth in autocorrelation is reduced, significantly for axial photons and only marginally for the transverse-directed photons. It is observed that the depth of modulation is reduced to a significantly lower and constant value as the storage modulus of the medium is increased. This constant value is found to be the same for both axial and transverse optical interrogation. This proves that the residual modulation depth is owing to refractive index fluctuations alone, which can be subtracted from the overall measured modulation depth, paving the way for a possible quantitative reconstruction of storage modulus. Moreover, since the transverse-directed photons are not significantly affected by storage modulus variations, for a quantitatively accurate read-out of absorption coefficient variation, the interrogating light should be perpendicular to the focusing ultrasound transducer axis.

  5. Establishing intensivist-driven ultrasound at the PICU bedside--it's about time*.

    PubMed

    Su, Erik; Pustavoitau, Aliaksei; Hirshberg, Elliotte L; Nishisaki, Akira; Conlon, Thomas; Kantor, David B; Weber, Mark D; Godshall, Aaron J; Burzynski, Jeffrey H; Thompson, Ann E

    2014-09-01

    To discuss pediatric intensivist-driven ultrasound and the exigent need for research and practice definitions pertaining to its implementation within pediatric critical care, specifically addressing issues in ultrasound-guided vascular access and intensivist-driven echocardiography. Intensivist-driven ultrasound improves procedure safety and reduces time to diagnosis in clinical ultrasound applications, as demonstrated primarily in adult patients. Translating these applications to the PICU requires thoughtful integration of the technology into practice and would best be informed by dedicated ultrasound research in critically ill children.

  6. Ultrasound physics and instrumentation for pathologists.

    PubMed

    Lieu, David

    2010-10-01

    Interest in pathologist-performed ultrasound-guided fine-needle aspiration is increasing. Educational courses discuss clinical ultrasound and biopsy techniques but not ultrasound physics and instrumentation. To review modern ultrasound physics and instrumentation to help pathologists understand the basis of modern ultrasound. A review of recent literature and textbooks was performed. Ultrasound physics and instrumentation are the foundations of clinical ultrasound. The key physical principle is the piezoelectric effect. When stimulated by an electric current, certain crystals vibrate and produce ultrasound. A hand-held transducer converts electricity into ultrasound, transmits it into tissue, and listens for reflected ultrasound to return. The returning echoes are converted into electrical signals and used to create a 2-dimensional gray-scale image. Scanning at a high frequency improves axial resolution but has low tissue penetration. Electronic focusing moves the long-axis focus to depth of the object of interest and improves lateral resolution. The short-axis focus in 1-dimensional transducers is fixed, which results in poor elevational resolution away from the focal zone. Using multiple foci improves lateral resolution but degrades temporal resolution. The sonographer can adjust the dynamic range to change contrast and bring out subtle masses. Contrast resolution is limited by processing speed, monitor resolution, and gray-scale perception of the human eye. Ultrasound is an evolving field. New technologies include miniaturization, spatial compound imaging, tissue harmonics, and multidimensional transducers. Clinical cytopathologists who understand ultrasound physics, instrumentation, and clinical ultrasound are ready for the challenges of cytopathologist-performed ultrasound-guided fine-needle aspiration and core-needle biopsy in the 21st century.

  7. Comparison of ultrasound imaging in transverse median and parasagittal oblique planes for thoracic epidurals: A pilot study.

    PubMed

    Khemka, Rakhi; Rastogi, Sonal; Desai, Neha; Chakraborty, Arunangshu; Sinha, Subir

    2016-06-01

    The use of ultrasound (US) scanning to assess the depth of epidural space to prevent neurological complications is established in current practice. In this study, we hypothesised that pre-puncture US scanning for estimating the depth of epidural space for thoracic epidurals is comparable between transverse median (TM) and paramedian sagittal oblique (PSO) planes. We performed pre-puncture US scanning in 32 patients, posted for open abdominal surgeries. The imaging was done to detect the depth of epidural space from skin (ultrasound depth [UD]) and needle insertion point, in parasagittal oblique plane in PSO group and transverse median plane in TM group. Subsequently, epidural space was localised through the predetermined insertion point by 'loss of resistance' technique and needle depth (ND) to the epidural space was marked. Correlation between the UD and actual ND was calculated and concordance correlation coefficient (CCC) was used to determine the degree of agreement between UD and ND in both the planes. The primary outcome, i.e., the comparison between UD and ND, done using Pearson correlation coefficient, was 0.99 in both PSO and TM groups, and the CCC was 0.93 (95% confidence interval [95% CI]: 0.81-0.97) and 0.90 (95% CI: 0.74-0.96) in PSO and TM groups respectively, which shows a strong positive association between UD and ND in both groups. The use of pre-puncture US scanning in both PSO and TM planes for estimating the depth of epidural space at the level of mid- and lower-thoracic spine is comparable.

  8. Intensification of the impact of high-intensity focused ultrasound (HIFU) with special spatiotemporal modulation

    NASA Astrophysics Data System (ADS)

    Gusev, V. A.; Rudenko, O. V.

    2013-01-01

    The principle of forming a special form of powerful acoustic signals is proposed, which makes it possible to ensure precise spatiotemporal beam focusing. The introduction of a transverse-coordinate-dependent local wave frequency is suggested, due to which the equality of the formation lengths of a discontinuity for all rays is achieved. This thereby ensures an increase in nonlinear absorption; as a result, the temperature and radiation action of focused ultrasound on the medium increase.

  9. Acrania/encephalocele sequence (exencephaly) associated with 92,XXXX karyotype: early prenatal diagnosis at 9(+5) weeks by 3D transvaginal ultrasound and coelocentesis.

    PubMed

    Tonni, Gabriele; Ventura, Alessandro; Bonasoni, Maria Paola

    2009-09-01

    A 27-year-old pregnant woman was diagnosed by 3D transvaginal ultrasound as carrying a fetus of 9(+5) weeks gestation affected by acrania/encephalocele (exencephaly) sequence. A 2D transvaginal ultrasound-guided aspiration of 5 mL of extra-coelomic fluid was performed under cervical block before uterine suction. Conventional cytogenetic analysis demonstrated a 92,XXXX karyotype. Transvaginal 2D ultrasound-guided coelocentesis for rapid karyotyping can be proposed to women who are near to miscarriage or in cases where a prenatal ultrasound diagnosis of congenital anomaly is performed at an early stage of development. Genetic analysis can be performed using traditional cytogenetic analysis or can be aided by fluorescence in situ hybridization (FISH). Coelocentesis may become an integral part of first trimester armamentarium and may be clinically useful in the understanding of the pathogenesis of early prenatally diagnosed congenital anomalies.

  10. Quadratus Lumborum Block Versus Transversus Abdominis Plane Block for Postoperative Pain After Cesarean Delivery: A Randomized Controlled Trial.

    PubMed

    Blanco, Rafael; Ansari, Tarek; Riad, Waleed; Shetty, Nanda

    Effective postoperative analgesia after cesarean delivery enhances early recovery, ambulation, and breastfeeding. In a previous study, we established the effectiveness of the quadratus lumborum block in providing pain relief after cesarean delivery compared with patient-controlled analgesia (morphine). In the current study, we hypothesized that this method would be equal to or better than the transversus abdominis plane block with regard to pain relief and its duration of action after cesarean delivery. Between April 2015 and August 2015, we randomized 76 patients scheduled for elective cesarean delivery under spinal anesthesia to receive the quadratus lumborum block or the transversus abdominis plane block for postoperative pain relief. This trial was registered prospectively (NCT 02489851) [corrected]. Patients in the quadratus lumborum block group used significantly less morphine than the transversus abdominis plane block group (P < 0.05) at 12, 24, and 48 hours but not at 4 and 6 hours after cesarean delivery. This group also had significantly fewer morphine demands than the control group (P < 0.05) at 6, 12, 24, and 48 hours after cesarean delivery. No significant differences in visual analog scale results were shown between the 2 groups at rest or with movement. Calculated total pain relief at rest and with movement were similar (P < 0.001) in both groups. The quadratus lumborum block was more effective in reducing morphine consumption and demands than transversus abdominis plane blocks after cesarean section. This effect was observed up to 48 hours postoperatively.

  11. Sexual dysfunction after colpectomy and vaginal reconstruction with a vertical rectus abdominis myocutaneous flap.

    PubMed

    Løve, Uffe S; Sjøgren, Pia; Rasmussen, Peter; Laurberg, Søren; Christensen, Henrik K

    2013-02-01

    The use of the vertical rectus abdominis myocutaneous flap in reconstruction after abdominoperineal resection or pelvic exenteration for neoplasia is well documented. However, functional outcomes after vaginal reconstruction, including sexual function, are poorly described. This study aimed to examine sexual function in women following extensive pelvic surgery with colpectomy and vaginal reconstruction with the use of a vertical rectus abdominis myocutaneous flap. This study is a retrospective review of medical records in combination with patient questionnaires. Nonresponders were followed up with a second contact. This study was performed at a tertiary care university medical center (Colorectal Section, Department of Surgery P, Aarhus University Hospital, Denmark) All women undergoing pelvic surgery and simultaneous vaginal reconstruction with the use of a vertical rectus abdominis myocutaneous flap between 2004 and 2010 at our department were identified from a patient database. Thirty women who were alive at the time of identification were included in the study. Sexual function before and after surgery was evaluated by the use of the Sexual function Vaginal changes Questionnaire. The main outcome end point was whether the patient was sexually active after vaginal reconstruction. Twenty-six participants (87%) answered the questionnaire. Fifty percent of patients reported an active sex life before surgery. In general, patients reported an unchanged desire for both physical and sexual contact after surgery. However, only 2 patients (14%) reported being sexually active after surgery. This was a retrospective study with a heterogeneous cohort involving several types of cancers and surgical procedures. Factors other than vertical rectus abdominis myocutaneous flap reconstruction itself may interfere with the sexual function. Extensive pelvic surgery with colpectomy leads to sexual dysfunction even when the vagina is reconstructed with a vertical rectus abdominis myocutaneous flap. This knowledge may improve the quality of information given to this group of patients before surgery.

  12. [Expression of tumor necrosis factor-like weak inducer of apoptosis in patients with gastric cancer and its relationship with nutritional status].

    PubMed

    Lu, Hang; Sun, Yuanshui

    2016-10-25

    To investigate the expression of tumor necrosis factor-like weak inducer of apoptosis (TWEAK) in the serum and the rectus abdominis muscle in patients with gastric cancer and its relationship with the nutritional status. Method Clinical data of 102 patients with gastric cancer (gastric cancer group) and 53 patients with benign abdominal disease (control group) who were admitted to Zhejiang Province People's Hospital from January 2008 to October 2013 were analyzed retrospectively. Enzyme-linked immunosorbent assay(ELISA) was used to detect the serum expression of TWEAK. Reverse transcription polymerase chain reaction (RT-PCR) and Western blot were used to detect the mRNA and protein expression of TWEAK in the rectus abdominis muscle. Relationship between TWEAK expression and nutritional status of gastric cancer patients was examined. The relative expression level of TWEAK protein in serum of gastric cancer group and control group was 0.403±0.065 and 0.148±0.036 respectively. The relative expression of TWEAK mRNA in the rectus abdominis muscle tissue was 0.313±0.089 (gastric cancer group) and 0.118±0.005 (control group). The relative expression of TWEAK protein in the rectus abdominis muscle tissue was 0.197±0.064 (gastric cancer group) and 0.066±0.014 (control group), and the differences were statistically significant (both P=0.000). The high expression of TWEAK (high than median) in rectus abdominis muscle of gastric cancer patients was related to the percentage of more than 10% decline in body weight (P=0.000), the small percentage of ideal body weight at the time of admission (P=0.000), BMI<20 kg/m 2 (P=0.023), higher NRS2002 nutritional risk screening score (P=0.000), lower prognostic nutrition index (P=0.000) and serum albumin <35 g/L (P=0.000). The expression of TWEAK in serum and rectus abdominis muscle of gastric cancer patients up-regulates compared to non-tumor patients. The expression level of TWEAK in the rectus abdominis muscle of gastric cancer patients is closely related to poor nutritional status, suggesting that TWEAK may play a key role in the process of cachexia of gastric cancer patients.

  13. Single-operator real-time ultrasound-guided spinal injection using SonixGPS™: a case series.

    PubMed

    Brinkmann, Silke; Tang, Raymond; Sawka, Andrew; Vaghadia, Himat

    2013-09-01

    The SonixGPS™ is a novel needle tracking system that has recently been approved in Canada for ultrasound-guided needle interventions. It allows optimization of needle-beam alignment by providing a real-time display of current and predicted needle tip position. Currently, there is limited evidence on the effectiveness of this technique for performance of real-time spinal anesthesia. This case series reports performance of the SonixGPS system for real-time ultrasound-guided spinal anesthesia in elective patients scheduled for joint arthroplasty. In this single-centre case series, 20 American Society of Anesthesiologists' class I-II patients scheduled for lower limb joint arthroplasty were recruited to undergo real-time ultrasound-guided spinal anesthesia with the SonixGPS after written informed consent. The primary outcome for this clinical cases series was the success rate of spinal anesthesia, and the main secondary outcome was time required to perform spinal anesthesia. Successful spinal anesthesia for joint arthroplasty was achieved in 18/20 patients, and 17 of these required only a single skin puncture. In 7/20 (35%) patients, dural puncture was achieved on the first needle pass, and in 11/20 (55%) patients, dural puncture was achieved with two or three needle redirections. Median (range) time taken to perform the block was 8 (5-14) min. The study procedure was aborted in two cases because our clinical protocol dictated using a standard approach if spinal anesthesia was unsuccessful after three ultrasound-guided insertion attempts. These two cases were classified as failures. No complications, including paresthesia, were observed during the procedure. All patients with successful spinal anesthesia found the technique acceptable and were willing to undergo a repeat procedure if deemed necessary. This case series shows that real-time ultrasound-guided spinal anesthesia with the SonixGPS system is possible within an acceptable time frame. It proved effective with a low rate of failure and a low rate of complications. Our clinical experience suggests that a randomized trial is warranted to compare the SonixGPS with a standard block technique.

  14. Sonoanatomic Variation of Pes Anserine Bursa

    PubMed Central

    Imani, Farnad; Abolhasan Gharehdag, Farid; Faiz, Seyed Hamid Reza

    2013-01-01

    Background The pes anserine bursa lies beneath the pes anserine tendon, which is the insertional tendon of the sartorius, gracilis, and semitendinosus muscles on the medial side of the tibia, but it can lie in different sites in the medial knee. Accurate diagnosis of the position of the bursa is critical for diagnostic and therapeutic goals. The aim of this study was to evaluate sonoanatomic variations of the pes anserine bursa in the medial knee. Methods One hundred seventy asymptomatic volunteers were enrolled in this study. Using ultrasound imaging (transverse approach, 7-13 MHz linear array probe) the sonoanatomic position of the pes anserine bursa and its relation to the pes anserine tendon were evaluated. Additionally, we evaluated the sonoanatomic variation of the saphenous nerve. Results The position of the pes anserine bursa was between the medial collateral ligament and the pes anserine tendons in 21.2%/18.8% (males/females) of subjects; between the pes anserine tendons and the tibia in 67.1%/64.7% (m/f); and among the pes anserine tendons in 8.2%/12.9% (m/f). No significant differences in the position of the bursa existed between males and females. The saphenous nerve was found within the pes anserine tendons in 77.6%/74.1% (m/f) of subjects, but outside the pes anserine tendons in 18.8%/15.3% (m/f). Visibility of sonoanatomic structures was not related to either gender or BMI. Conclusions Ultrasound provides very accurate information about variations in the pes anserine bursa and the saphenous nerve. This suggests that our proposed ultrasound method can be a reliable guide to facilitate approaches to the medial knee for diagnostic and therapeutic objectives. PMID:23861998

  15. Evaluation of a Standardized Program for Training Practicing Anesthesiologists in Ultrasound-Guided Regional Anesthesia Skills.

    PubMed

    Mariano, Edward R; Harrison, T Kyle; Kim, T Edward; Kan, Jack; Shum, Cynthia; Gaba, David M; Ganaway, Toni; Kou, Alex; Udani, Ankeet D; Howard, Steven K

    2015-10-01

    Practicing anesthesiologists have generally not received formal training in ultrasound-guided perineural catheter insertion. We designed this study to determine the efficacy of a standardized teaching program in this population. Anesthesiologists in practice for 10 years or more were recruited and enrolled to participate in a 1-day program: lectures and live-model ultrasound scanning (morning) and faculty-led iterative practice and mannequin-based simulation (afternoon). Participants were assessed and recorded while performing ultrasound-guided perineural catheter insertion at baseline, at midday (interval), and after the program (final). Videos were scored by 2 blinded reviewers using a composite tool and global rating scale. Participants were surveyed every 3 months for 1 year to report the number of procedures, efficacy of teaching methods, and implementation obstacles. Thirty-two participants were enrolled and completed the program; 31 of 32 (97%) completed the 1-year follow-up. Final scores [median (10th-90th percentiles)] were 21.5 (14.5-28.0) of 30 points compared to 14.0 (9.0-20.0) at interval (P < .001 versus final) and 12.0 (8.5-17.5) at baseline (P < .001 versus final), with no difference between interval and baseline. The global rating scale showed an identical pattern. Twelve of 26 participants without previous experience performed at least 1 perineural catheter insertion after training (P < .001). However, there were no differences in the monthly average number of procedures or complications after the course when compared to baseline. Practicing anesthesiologists without previous training in ultrasound-guided regional anesthesia can acquire perineural catheter insertion skills after a 1-day standardized course, but changing clinical practice remains a challenge. © 2015 by the American Institute of Ultrasound in Medicine.

  16. Ultrasonography in Acupuncture-Uses in Education and Research.

    PubMed

    Leow, Mabel Qi He; Cui, Shu Li; Mohamed Shah, Mohammad Taufik Bin; Cao, Taige; Tay, Shian Chao; Tay, Peter Kay Chai; Ooi, Chin Chin

    2017-06-01

    This study aims to explore the potential use of ultrasound in locating the second posterior sacral foramen acupuncture point, quantifying depth of insertion and describing surrounding anatomical structures. We performed acupuncture needle insertion on a study team member. There were four steps in our experiment. First, the acupuncturist located the acupuncture point by palpation. Second, we used an ultrasound machine to visualize the structures surrounding the location of the acupuncture point and measure the depth required for needle insertion. Third, the acupuncturist inserted the acupuncture needle into the acupuncture point at an angle of 30°. Fourth, we performed another ultrasound scan to ensure that the needle was in the desired location. Results suggested that ultrasound could be used to locate the acupuncture point and estimate the depth of needle insertion. The needle was inserted to a depth of 4.0 cm to reach the surface of the sacral foramen. Based on Pythagoras theorem, taking a needle insertion angle of 30° and a needle insertion depth of 4.0 cm, the estimated perpendicular depth is 1.8 cm. An ultrasound scan corroborated the depth of 1.85 cm. The use of an ultrasound-guided technique for needle insertion in acupuncture practice could help standardize the treatment. Clinicians and students would be able to visualize and measure the depth of the sacral foramen acupuncture point, to guide the depth of needle insertion. This methodological guide could also be used to create a standard treatment protocol for research. A similar mathematical guide could also be created for other acupuncture points in future. Copyright © 2017. Published by Elsevier B.V.

  17. Theoretical Analysis of the Accuracy and Safety of MRI-Guided Transurethral 3-D Conformal Ultrasound Prostate Therapy

    NASA Astrophysics Data System (ADS)

    Burtnyk, Mathieu; Chopra, Rajiv; Bronskill, Michael

    2009-04-01

    MRI-guided transurethral ultrasound therapy is a promising new approach for the treatment of localized prostate cancer. Several studies have demonstrated the feasibility of producing large regions of thermal coagulation adequate for prostate therapy; however, the quantitative assessment of shaping these regions to complex 3-D human prostate geometries has not been fully explored. This study used numerical simulations and twenty manually-segmented pelvic anatomical models derived from high-quality MR images of prostate cancer patients to evaluate the treatment accuracy and safety of 3-D conformal MRI-guided transurethral ultrasound therapy. The simulations incorporated a rotating multi-element planar dual-frequency ultrasound transducer (seventeen 4×3 mm elements) operating at 4.7/9.7 MHz and 10 W/cm2 maximum acoustic power. Results using a novel feedback control algorithm which modulated the ultrasound frequency, power and device rate of rotation showed that regions of thermal coagulation could be shaped to predefined prostate volumes within 1.0 mm across the vast majority of these glands. Treatment times were typically 30 min and remained below 60 min for large 60 cc prostates. With a rectal cooling temperature of 15° C, the rectal wall did not exceed 30EM43 in half of the twenty patient models with only a few 1 mm3 voxels above this threshold in the other cases. At 4.7 MHz, heating of the pelvic bone can become significant when it is located less than 10 mm from the prostate. Numerical simulations show that MRI-guided transurethral ultrasound therapy can thermally coagulate whole prostate glands accurately and safely in 3-D.

  18. Treatment of Partial Rotator Cuff Tear with Ultrasound-guided Platelet-rich Plasma

    PubMed Central

    Sengodan, Vetrivel Chezian; Kurian, Sajith; Ramasamy, Raghupathy

    2017-01-01

    Background: The treatment of symptomatic partial rotator cuff tear has presented substantial challenge to orthopaedic surgeons as it can vary from conservative to surgical repair. Researches have established the influence of platelet rich plasma in healing damaged tissue. Currently very few data are available regarding the evidence of clinical and radiological outcome of partial rotator cuff tear treated with ultrasound guided platelet rich plasma injection in English literature. Materials and Methods: 20 patients with symptomatic partial rotator cuff tears were treated with ultrasound guided platelet rich plasma injection. Before and after the injection of platelet rich plasma scoring was done with visual analogue score, Constant shoulder score, and UCLA shoulder score at 8 weeks and third month. A review ultrasound was performed 8 weeks after platelet rich plasma injection to assess the rotator cuff status. Results: Our study showed statistically significant improvements in 17 patients in VAS pain score, constant shoulder score and UCLA shoulder score. No significant changes in ROM were noted when matched to the contra-lateral side (P < 0.001) at the 3 month follow-up. The study also showed good healing on radiological evaluation with ultrasonogram 8 weeks after platelet rich plasma injection. Conclusion: Ultrasound guided platelet rich plasma injection for partial rotator cuff tears is an effective procedure that leads to significant decrease in pain, improvement in shoulder functions, much cost-effective and less problematic compared to a surgical treatment. PMID:28900553

  19. Ultrasound-Guided Pulsed Radiofrequency Stimulation of Posterior Tibial Nerve: A Potential Novel Intervention for Recalcitrant Plantar Fasciitis.

    PubMed

    Wu, Yung-Tsan; Chang, Chih-Ya; Chou, Yu-Ching; Yeh, Chun-Chang; Li, Tsung-Ying; Chu, Heng-Yi; Chen, Liang-Cheng

    2017-05-01

    To evaluate the therapeutic benefit of ultrasound-guided pulsed radiofrequency (PRF) stimulation at the posterior tibial nerve (PTN) in patients with recalcitrant plantar fasciitis (PF). A prospective, randomized, double-blinded, placebo-controlled trial (12-wk follow-up). Outpatient local medical center settings. Patients (N=36) with recalcitrant PF underwent randomization, and all were included in the final data analysis. Patients in the PRF group were treated with 1 dose of ultrasound-guided PRF stimulation at the PTN, and those in the control group received 1 dose of 2% lidocaine, 0.5mL, injected at the PTN under ultrasound guidance. The visual analog scale (first-step and overall pain), American Orthopedic Foot-Ankle Society (AOFAS) ankle-hindfoot scale, and ultrasonographic thickness of the plantar fascia were evaluated at 1, 4, 8, and 12 weeks after treatment. Thirty-six patients (20 feet per group) completed the study. The PRF group had a significantly larger improvement in first-step pain, overall pain, and AOFAS score (all P<.001), as well as plantar fascia thickness (P<.05), compared with those of the control group at all observed time points. This study shows that ultrasound-guided PRF stimulation at the PTN is effective for treating recalcitrant PF. This simple, reproducible method could be a novel strategy for managing recalcitrant PF. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  20. Real-time visualization of ultrasound-guided retrobulbar blockade: an imaging study.

    PubMed

    Luyet, C; Eichenberger, U; Moriggl, B; Remonda, L; Greif, R

    2008-12-01

    Retrobulbar anaesthesia allows eye surgery in awake patients. Severe complications of the blind techniques are reported. Ultrasound-guided needle introduction and direct visualization of the spread of local anaesthetic may improve quality and safety of retrobulbar anaesthesia. Therefore, we developed a new ultrasound-guided technique using human cadavers. In total, 20 blocks on both sides in 10 embalmed human cadavers were performed. Using a small curved array transducer and a long-axis approach, a 22 G short bevel needle was introduced under ultrasound guidance lateral and caudal of the eyeball until the needle tip was seen 2 mm away from the optic nerve. At this point, 2 ml of contrast dye as a substitute for local anaesthetic was injected. Immediately after the injection, the spread of the contrast dye was documented by means of CT scans performed in each cadaver. The CT scans showed the distribution of the contrast dye in the muscle cone and behind the posterior sclera in all but one case. No contrast dye was found inside the optic nerve or inside the eyeball. In one case, there could be an additional trace of contrast dye behind the orbita. Our new ultrasound-guided technique has the potential to improve safety and efficacy of the procedure by direct visualization of the needle placement and the distribution of the injected fluid. Furthermore, the precise injection near the optic nerve could lead to a reduction of the amount of the local anaesthetic needed with fewer related complications.

  1. Breast cancer: determining the genetic profile from ultrasound-guided percutaneous biopsy specimens obtained during the diagnostic workups.

    PubMed

    López Ruiz, J A; Zabalza Estévez, I; Mieza Arana, J A

    2016-01-01

    To evaluate the possibility of determining the genetic profile of primary malignant tumors of the breast from specimens obtained by ultrasound-guided percutaneous biopsies during the diagnostic imaging workup. This is a retrospective study in 13 consecutive patients diagnosed with invasive breast cancer by B-mode ultrasound-guided 12 G core needle biopsy. After clinical indication, the pathologist decided whether the paraffin block specimens seemed suitable (on the basis of tumor size, validity of the sample, and percentage of tumor cells) before sending them for genetic analysis with the MammaPrint® platform. The size of the tumors on ultrasound ranged from 0.6cm to 5cm. In 11 patients the preserved specimen was considered valid and suitable for use in determining the genetic profile. In 1 patient (with a 1cm tumor) the pathologist decided that it was necessary to repeat the core biopsy to obtain additional samples. In 1 patient (with a 5cm tumor) the specimen was not considered valid by the genetic laboratory. The percentage of tumor cells in the samples ranged from 60% to 70%. In 11/13 cases (84.62%) it was possible to do the genetic analysis on the previously diagnosed samples. In most cases, regardless of tumor size, it is possible to obtain the genetic profile from tissue specimens obtained with ultrasound-guided 12 G core biopsy preserved in paraffin blocks. Copyright © 2015 SERAM. Published by Elsevier España, S.L.U. All rights reserved.

  2. Ultrasound-guided percutaneous fine-needle aspiration of 545 focal pancreatic lesions.

    PubMed

    Zamboni, Giulia A; D'Onofrio, Mirko; Idili, Antonio; Malagò, Roberto; Iozzia, Roberta; Manfrin, Erminia; Mucelli, Roberto Pozzi

    2009-12-01

    The purpose of this study was to assess the accuracy and short-term complication rate of ultrasound-guided fine-needle aspiration cytologic sampling of focal pancreatic lesions. We reviewed 545 consecutive ultrasound-guided fine-needle aspiration cytologic sampling procedures for focal pancreatic lesions from January 2004 through June 2008. The procedures were performed with a 20- or 21-gauge needle. The onsite cytopathologist evaluated the appropriateness of the sample and made a diagnosis. We reviewed the final diagnosis and the radiologic and medical records of all patients for onset of complications during or within 7 days of the procedure. The study sample included 262 women and 283 men (mean age, 62 years; range, 25-86 years). The head or uncinate process of the pancreas was the location of 63.0% of the lesions, and 35.2% of the lesions were located in the body or tail of the pancreas. The site of 10 lesions (1.8%) was not specified. Sampling was diagnostic in 509 of the 545 cases (93.4%). Excluding the 36 nondiagnostic samples, ultrasound-guided fine-needle aspiration cytologic sampling had 99.4% sensitivity, 100% specificity, and 99.4% accuracy. In 537 of the 545 cases (98.5%), the procedure was uneventful. In two cases, abdominal fluid was found after the procedure that was not present before the procedure. Six patients experienced postprocedural pain without abnormal findings at subsequent imaging. No major complications occurred. Ultrasound-guided cytologic sampling is safe and accurate for the diagnosis and planning of management of focal pancreatic lesions. With a cytologist on site, the rate of acquisition of samples adequate for diagnosis is high, reducing the need for patient recall.

  3. TU-B-210-00: MR-Guided Focused Ultrasound Therapy in Oncology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    MR guided focused ultrasound (MRgFUS), or alternatively high-intensity focused ultrasound (MRgHIFU), is approved for thermal ablative treatment of uterine fibroids and pain palliation in bone metastases. Ablation of malignant tumors is under active investigation in sites such as breast, prostate, brain, liver, kidney, pancreas, and soft tissue. Hyperthermia therapy with MRgFUS is also feasible, and may be used in conjunction with radiotherapy and for local targeted drug delivery. MRI allows in situ target definition and provides continuous temperature monitoring and subsequent thermal dose mapping during HIFU. Although MRgHIFU can be very precise, treatment of mobile organs is challenging and advancedmore » techniques are required because of artifacts in MR temperature mapping, the need for intercostal firing, and need for gated HIFU or tracking of the lesion in real time. The first invited talk, “MR guided Focused Ultrasound Treatment of Tumors in Bone and Soft Tissue”, will summarize the treatment protocol and review results from treatment of bone tumors. In addition, efforts to extend this technology to treat both benign and malignant soft tissue tumors of the extremities will be presented. The second invited talk, “MRI guided High Intensity Focused Ultrasound – Advanced Approaches for Ablation and Hyperthermia”, will provide an overview of techniques that are in or near clinical trials for thermal ablation and hyperthermia, with an emphasis of applications in abdominal organs and breast, including methods for MRTI and tracking targets in moving organs. Learning Objectives: Learn background on devices and techniques for MR guided HIFU for cancer therapy Understand issues and current status of clinical MRg HIFU Understand strategies for compensating for organ movement during MRgHIFU Understand strategies for strategies for delivering hyperthermia with MRgHIFU CM - research collaboration with Philips.« less

  4. Ultrasound-Guided Core-Needle Versus Vacuum-Assisted Breast Biopsy: A Cost Analysis Based on the American Society of Breast Surgeons' Mastery of Breast Surgery Registry.

    PubMed

    Grady, Ian; Vasquez, Tony; Tawfik, Sara; Grady, Sean

    2017-03-01

    To evaluate the cost-efficacy of vacuum-assisted ultrasound-guided breast biopsy instruments compared to ultrasound-guided 14-gauge spring-loaded core-needle biopsy. The American Society of Breast Surgeons' Mastery of Breast Surgery Registry was reviewed. Biopsy findings, any rebiopsy, and the instrument used were abstracted for 31,451 ultrasound-guided biopsy procedures performed between 2001 and July 2014. Rates of cancer diagnosis and rebiopsy were calculated for each instrument. A linear mathematical model was developed to calculate total cost per cancer diagnosis, including procedural costs and the costs of any additional surgical rebiopsy procedures. Mean cost per cancer diagnosis with confidence limits was then determined for 14-gauge spring-loaded core-needle biopsy and 14 different vacuum-assisted instruments. For 14-gauge spring-loaded core-needle biopsy, mean cost per cancer diagnosis was $4346 (4327-$4366). For the vacuum-assisted instruments, mean cost per cancer diagnosis ranged from a low of $3742 ($3732-$3752) to a high of $4779 ($4750-$4809). Vacuum-assisted instruments overall were more cost-effective than core with a mean cost per cancer diagnosis of $4052 ($4038-$4067) (p < 0.05). Tethered vacuum-assisted instruments performed best with a mean cost per cancer diagnosis of $3978 ($3964-$3991) (p < 0.05). Nontethered devices had a mean cost per cancer diagnosis of $4369 ($4350-$4388), a result no better than core (p < 0.05). Ultrasound-guided vacuum-assisted breast biopsy had a lower mean cost per cancer diagnosis than 14-gauge spring-loaded core-needle biopsy. This advantage was only seen in tethered vacuum-assisted instruments. Within device families, larger instruments tended to outperform smaller instruments.

  5. Magnetic resonance imaging-guided focused ultrasound treatment of symptomatic uterine fibroids: impact of technology advancement on ablation volumes in 115 patients.

    PubMed

    Trumm, Christoph G; Stahl, Robert; Clevert, Dirk-André; Herzog, Peter; Mindjuk, Irene; Kornprobst, Sabine; Schwarz, Christina; Hoffmann, Ralf-Thorsten; Reiser, Maximilian F; Matzko, Matthias

    2013-06-01

    The aim of this study was to assess the impact of the advanced technology of the new ExAblate 2100 system (Insightec Ltd, Haifa, Israel) for magnetic resonance imaging (MRI)-guided focused ultrasound surgery on treatment outcomes in patients with symptomatic uterine fibroids, as measured by the nonperfused volume ratio. This is a retrospective analysis of 115 women (mean age, 42 years; range, 27-54 years) with symptomatic fibroids who consecutively underwent MRI-guided focused ultrasound treatment in a single center with the new generation ExAblate 2100 system from November 2010 to June 2011. Mean ± SD total volume and number of treated fibroids (per patient) were 89 ± 94 cm and 2.2 ± 1.7, respectively. Patient baseline characteristics were analyzed regarding their impact on the resulting nonperfused volume ratio. Magnetic resonance imaging-guided focused ultrasound treatment was technically successful in 115 of 123 patients (93.5%). In 8 patients, treatment was not possible because of bowel loops in the beam pathway that could not be mitigated (n = 6), patient movement (n = 1), and system malfunction (n = 1). Mean nonperfused volume ratio was 88% ± 15% (range, 38%-100%). Mean applied energy level was 5400 ± 1200 J, and mean number of sonications was 74 ± 27. No major complications occurred. Two cases of first-degree skin burn resolved within 1 week after the intervention. Of the baseline characteristics analyzed, only the planned treatment volume had a statistically significant impact on nonperfused volume ratio. With technological advancement, the outcome of MRI-guided focused ultrasound treatment in terms of the nonperfused volume ratio can be enhanced with a high safety profile, markedly exceeding results reported in previous clinical trials.

  6. Mixed reality ultrasound guidance system: a case study in system development and a cautionary tale.

    PubMed

    Ameri, Golafsoun; Baxter, John S H; Bainbridge, Daniel; Peters, Terry M; Chen, Elvis C S

    2018-04-01

    Real-time ultrasound has become a crucial aspect of several image-guided interventions. One of the main constraints of such an approach is the difficulty in interpretability of the limited field of view of the image, a problem that has recently been addressed using mixed reality, such as augmented reality and augmented virtuality. The growing popularity and maturity of mixed reality has led to a series of informal guidelines to direct development of new systems and to facilitate regulatory approval. However, the goals of mixed reality image guidance systems and the guidelines for their development have not been thoroughly discussed. The purpose of this paper is to identify and critically examine development guidelines in the context of a mixed reality ultrasound guidance system through a case study. A mixed reality ultrasound guidance system tailored to central line insertions was developed in close collaboration with an expert user. This system outperformed ultrasound-only guidance in a novice user study and has obtained clearance for clinical use in humans. A phantom study with 25 experienced physicians was carried out to compare the performance of the mixed reality ultrasound system against conventional ultrasound-only guidance. Despite the previous promising results, there was no statistically significant difference between the two systems. Guidelines for developing mixed reality image guidance systems cannot be applied indiscriminately. Each design decision, no matter how well justified, should be the subject of scientific and technical investigation. Iterative and small-scale evaluation can readily unearth issues and previously unknown or implicit system requirements. We recommend a wary eye in development of mixed reality ultrasound image guidance systems emphasizing small-scale iterative evaluation alongside system development. Ultimately, we recommend that the image-guided intervention community furthers and deepens this discussion into best practices in developing image-guided interventions.

  7. Toward a real-time system for temporal enhanced ultrasound-guided prostate biopsy.

    PubMed

    Azizi, Shekoofeh; Van Woudenberg, Nathan; Sojoudi, Samira; Li, Ming; Xu, Sheng; Abu Anas, Emran M; Yan, Pingkun; Tahmasebi, Amir; Kwak, Jin Tae; Turkbey, Baris; Choyke, Peter; Pinto, Peter; Wood, Bradford; Mousavi, Parvin; Abolmaesumi, Purang

    2018-03-27

    We have previously proposed temporal enhanced ultrasound (TeUS) as a new paradigm for tissue characterization. TeUS is based on analyzing a sequence of ultrasound data with deep learning and has been demonstrated to be successful for detection of cancer in ultrasound-guided prostate biopsy. Our aim is to enable the dissemination of this technology to the community for large-scale clinical validation. In this paper, we present a unified software framework demonstrating near-real-time analysis of ultrasound data stream using a deep learning solution. The system integrates ultrasound imaging hardware, visualization and a deep learning back-end to build an accessible, flexible and robust platform. A client-server approach is used in order to run computationally expensive algorithms in parallel. We demonstrate the efficacy of the framework using two applications as case studies. First, we show that prostate cancer detection using near-real-time analysis of RF and B-mode TeUS data and deep learning is feasible. Second, we present real-time segmentation of ultrasound prostate data using an integrated deep learning solution. The system is evaluated for cancer detection accuracy on ultrasound data obtained from a large clinical study with 255 biopsy cores from 157 subjects. It is further assessed with an independent dataset with 21 biopsy targets from six subjects. In the first study, we achieve area under the curve, sensitivity, specificity and accuracy of 0.94, 0.77, 0.94 and 0.92, respectively, for the detection of prostate cancer. In the second study, we achieve an AUC of 0.85. Our results suggest that TeUS-guided biopsy can be potentially effective for the detection of prostate cancer.

  8. Endoscopic ultrasound-guided choledochoduodenostomy after a failed or impossible ERCP.

    PubMed

    Mora Soler, Ana María; Álvarez Delgado, Alberto; Piñero Pérez, María Concepción; Velasco-Guardado, Antonio; Marcos Prieto, Héctor; Rodríguez Pérez, Antonio

    2018-05-01

    endoscopic ultrasound-guided biliary drainage (EUS-BD) is an alternative to percutaneous trans-hepatic biliary drainage (PTBD) in cases of failed endoscopic retrograde cholangiopancreatography (ERCP). this is a retrospective description of six cases of endoscopic ultrasound-guided biliary drainage via choledochoduodenostomy (EUCD), as well as the clinical characteristics, endoscopic procedure, complications and monitoring. all cases had malignant distal biliary obstruction. The procedure was concluded with good drainage in four out of six patients. Two late complications were recorded that were caused by stent migration and there were no deaths related with the procedure. The average monitoring period was six months. EUCD can be considered as a valid therapeutic choice in some selected cases and when performed by a team of expert endoscopists in cases of failed ERCP drainage or as an alternative to PTBD. However, the procedure has some associated complications.

  9. Magnetic resonance guided high-intensity focused ultrasound ablation of musculoskeletal tumors

    PubMed Central

    Avedian, Raffi S.; Gold, Garry; Ghanouni, Pejman; Pauly, Kim Butts

    2015-01-01

    This article reviews the fundamental principles and clinical experimental uses of magnetic resonance guided high-intensity focused ultrasound (MRgHIFU) ablation of musculoskeletal tumors. MRgHIFU is a noninvasive treatment modality that takes advantage of the ability of magnetic resonance to measure tissue temperature and uses this technology to guide high-intensity focused ultrasound waves to a specific focus within the human body that results in heat generation and complete thermal necrosis of the targeted tissue. Adjacent normal tissues are spared because of the accurate delivery of thermal energy, as well as, local blood perfusion that provides a cooling effect. MRgHIFU is approved by the Food and Drug Administration for the treatment of uterine fibroids and is used on an experimental basis to treat breast, prostate, liver, bone, and brain tumors. PMID:26120376

  10. Ultrasound-guided central venous access using Google Glass.

    PubMed

    Wu, Teresa S; Dameff, Christian J; Tully, Jeffrey L

    2014-12-01

    The use of ultrasound during invasive bedside procedures is quickly becoming the standard of care. Ultrasound machine placement during procedures often requires the practitioner to turn their head during the procedure to view the screen. Such turning has been implicated in unintentional hand movements in novices. Google Glass is a head-mounted computer with a specialized screen capable of projecting images and video into the view of the wearer. Such technology may help decrease unintentional hand movements. Our aim was to evaluate whether or not medical practitioners at various levels of training could use Google Glass to perform an ultrasound-guided procedure, and to explore potential advantages of this technology. Forty participants of varying training levels were randomized into two groups. One group used Google Glass to perform an ultrasound-guided central line. The other group used traditional ultrasound during the procedure. Video recordings of eye and hand movements were analyzed. All participants from both groups were able to complete the procedure without difficulty. Google Glass wearers took longer to perform the procedure at all training levels (medical student year 1 [MS1]: 193 s vs. 77 s, p > 0.5; MS4: 197s vs. 91s, p ≤ 0.05; postgraduate year 1 [PGY1]: 288s vs. 125 s, p > 0.5; PGY3: 151 s vs. 52 s, p ≤ 0.05), and required more needle redirections (MS1: 4.4 vs. 2.0, p > 0.5; MS4: 4.8 vs. 2.8, p > 0.5; PGY1: 4.4 vs. 2.8, p > 0.5; PGY3: 2.0 vs. 1.0, p > 0.5). In this study, it was possible to perform ultrasound-guided procedures with Google Glass. Google Glass wearers, on average, took longer to gain access, and had more needle redirections, but less head movements were noted. Copyright © 2014 Elsevier Inc. All rights reserved.

  11. A randomised crossover study to compare the cross-sectional and longitudinal approaches to ultrasound-guided peripheral venepuncture in a model.

    PubMed

    Griffiths, James; Carnegie, Amadeus; Kendall, Richard; Madan, Rajeev

    2017-12-01

    Ultrasound-guided peripheral intravenous access may present an alternative to central or intraosseous access in patients with difficult peripheral veins. Using venepuncture of a phantom model as a proxy, we investigated whether novice ultrasound users should adopt a cross-sectional or longitudinal approach when learning to access peripheral veins under ultrasound guidance. This result would inform the development of a structured training method for this procedure. We conducted a randomised controlled trial of 30 medical students. Subjects received 35 min of training, then attempted to aspirate 1 ml of synthetic blood from a deep vein in a training model under ultrasound guidance. Subjects attempted both the cross-sectional and longitudinal approaches. Group 1 used cross-sectional first, followed by longitudinal. Group 2 used longitudinal first, then cross-sectional. We measured the time from first puncture of the model's skin to aspiration of fluid, and the number of attempts required. Subjects also reported difficulty ratings for each approach. Paired sample t-tests were used for statistical analysis. The mean number of attempts was 1.13 using the cross-sectional approach, compared with 1.30 using the longitudinal approach (p = 0.17). Mean time to aspiration of fluid was 45.1 s using the cross-sectional approach and 52.8 s using the longitudinal approach (p = 0.43). The mean difficulty score out of 10 was 3.97 for the cross-sectional approach and 3.93 for the longitudinal approach (p = 0.95). We found no significant difference in effectiveness between the cross-sectional and longitudinal approaches to ultrasound-guided venepuncture when performed on a model. We believe that both approaches should be included when teaching ultrasound-guided peripheral vascular access. To confirm which approach would be best in clinical practice, we advocate future testing of both approaches on patients.

  12. Evaluation of cost-effectiveness from the funding body's point of view of ultrasound-guided central venous catheter insertion compared with the conventional technique.

    PubMed

    Noritomi, Danilo Teixeira; Zigaib, Rogério; Ranzani, Otavio T; Teich, Vanessa

    2016-01-01

    To evaluate the cost-effectiveness, from the funding body's point of view, of real-time ultrasound-guided central venous catheter insertion compared to the traditional method, which is based on the external anatomical landmark technique. A theoretical simulation based on international literature data was applied to the Brazilian context, i.e., the Unified Health System (Sistema Único de Saúde - SUS). A decision tree was constructed that showed the two central venous catheter insertion techniques: real-time ultrasonography versus external anatomical landmarks. The probabilities of failure and complications were extracted from a search on the PubMed and Embase databases, and values associated with the procedure and with complications were taken from market research and the Department of Information Technology of the Unified Health System (DATASUS). Each central venous catheter insertion alternative had a cost that could be calculated by following each of the possible paths on the decision tree. The incremental cost-effectiveness ratio was calculated by dividing the mean incremental cost of real-time ultrasound compared to the external anatomical landmark technique by the mean incremental benefit, in terms of avoided complications. When considering the incorporation of real-time ultrasound and the concomitant lower cost due to the reduced number of complications, the decision tree revealed a final mean cost for the external anatomical landmark technique of 262.27 Brazilian reals (R$) and for real-time ultrasound of R$187.94. The final incremental cost of the real-time ultrasound-guided technique was -R$74.33 per central venous catheter. The incremental cost-effectiveness ratio was -R$2,494.34 due to the pneumothorax avoided. Real-time ultrasound-guided central venous catheter insertion was associated with decreased failure and complication rates and hypothetically reduced costs from the view of the funding body, which in this case was the SUS.

  13. The Agreement between Auscultation and Lung Ultrasound in Hemodialysis Patients: The LUST Study.

    PubMed

    Torino, Claudia; Gargani, Luna; Sicari, Rosa; Letachowicz, Krzysztof; Ekart, Robert; Fliser, Danilo; Covic, Adrian; Siamopoulos, Kostas; Stavroulopoulos, Aristeidis; Massy, Ziad A; Fiaccadori, Enrico; Caiazza, Alberto; Bachelet, Thomas; Slotki, Itzchak; Martinez-Castelao, Alberto; Coudert-Krier, Marie-Jeanne; Rossignol, Patrick; Gueler, Faikah; Hannedouche, Thierry; Panichi, Vincenzo; Wiecek, Andrzej; Pontoriero, Giuseppe; Sarafidis, Pantelis; Klinger, Marian; Hojs, Radovan; Seiler-Mussler, Sarah; Lizzi, Fabio; Siriopol, Dimitrie; Balafa, Olga; Shavit, Linda; Tripepi, Rocco; Mallamaci, Francesca; Tripepi, Giovanni; Picano, Eugenio; London, Gérard Michel; Zoccali, Carmine

    2016-11-07

    Accumulation of fluid in the lung is the most concerning sequela of volume expansion in patients with ESRD. Lung auscultation is recommended to detect and monitor pulmonary congestion, but its reliability in ESRD is unknown. In a subproject of the ongoing Lung Water by Ultra-Sound Guided Treatment to Prevent Death and Cardiovascular Complications in High Risk ESRD Patients with Cardiomyopathy Trial, we compared a lung ultrasound-guided ultrafiltration prescription policy versus standard care in high-risk patients on hemodialysis. The reliability of peripheral edema was tested as well. This study was on the basis of 1106 pre- and postdialysis lung ultrasound studies (in 79 patients) simultaneous with standardized lung auscultation (crackles at the lung bases) and quantification of peripheral edema. Lung congestion by crackles, edema, or a combination thereof poorly reflected the severity of congestion as detected by ultrasound B lines in various analyses, including standard regression analysis weighting for repeated measures in individual patients (shared variance of 12% and 4% for crackles and edema, respectively) and κ-statistics (κ ranging from 0.00 to 0.16). In general, auscultation had very low discriminatory power for the diagnosis of mild (area under the receiver operating curve =0.61), moderate (area under the receiver operating curve =0.65), and severe (area under the receiver operating curve =0.68) lung congestion, and the same was true for peripheral edema (receiver operating curve =0.56 or lower) and the combination of the two physical signs. Lung crackles, either alone or combined with peripheral edema, very poorly reflect interstitial lung edema in patients with ESRD. These findings reinforce the rationale underlying the Lung Water by Ultra-Sound Guided Treatment to Prevent Death and Cardiovascular Complications in High Risk ESRD Patients with Cardiomyopathy Trial, a trial adopting ultrasound B lines as an instrument to guide interventions aimed at mitigating lung congestion in high-risk patients on hemodialysis. Copyright © 2016 by the American Society of Nephrology.

  14. Porcine lens nuclei as a model for comparison of 3 ultrasound modalities regarding efficiency and chatter.

    PubMed

    Oakey, Zack B; Jensen, Jason D; Zaugg, Brian E; Radmall, Bryce R; Pettey, Jeff H; Olson, Randall J

    2013-08-01

    To validate a porcine lens model by comparing density and ultrasound (US) with known human standards using the Infiniti Ozil with Intelligent Phacoemulsification (torsional), Whitestar Signature Micropulse (longitudinal), and Ellips FX (transversal) modalities. Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. Experimental study. Lens nuclei were formalin soaked in hour-based intervals and divided into 2.0 mm cubes. Density was characterized by crushing experiments and compared with known human measures. Efficiency and chatter were examined. The mean weight to cut thickness in half ranged from 16.9 g ± 5.5 (SD) in the 0-hour group to 121.3 ± 47.5 gm in the 4-hour group. Lenses in the 2-hour group (mean 70.2 ± 19.1 g) best matched human density (P=.215). The mean efficiency ranged from 0.432 ± 0.178 seconds to 9.111 ± 2.925 seconds; chatter ranged from zero to 1.85 ± 1.927 bounces. No significant difference was detected when comparing the 2-hour formalin group with human lenses in torsional and transversal US. There was no significant difference between transversal and torsional modalities, consistent with human studies. Although longitudinal (6 milliseconds on, 12 milliseconds off) was significantly more efficient at 50% power than at 25%, there was no significant difference compared with transversal or torsional US. Animal lenses soaked for 2 hours in formalin were most comparable to human lenses. Longitudinal US may be an acceptable alternative to torsional and transversal US. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  15. Integrated ultrasound and magnetic resonance imaging for simultaneous temperature and cavitation monitoring during focused ultrasound therapies

    PubMed Central

    Arvanitis, Costas D.; McDannold, Nathan

    2013-01-01

    Purpose: Ultrasound can be used to noninvasively produce different bioeffects via viscous heating, acoustic cavitation, or their combination, and these effects can be exploited to develop a wide range of therapies for cancer and other disorders. In order to accurately localize and control these different effects, imaging methods are desired that can map both temperature changes and cavitation activity. To address these needs, the authors integrated an ultrasound imaging array into an MRI-guided focused ultrasound (MRgFUS) system to simultaneously visualize thermal and mechanical effects via passive acoustic mapping (PAM) and MR temperature imaging (MRTI), respectively. Methods: The system was tested with an MRgFUS system developed for transcranial sonication for brain tumor ablation in experiments with a tissue mimicking phantom and a phantom-filled ex vivo macaque skull. In experiments on cavitation-enhanced heating, 10 s continuous wave sonications were applied at increasing power levels (30–110 W) until broadband acoustic emissions (a signature for inertial cavitation) were evident. The presence or lack of signal in the PAM, as well as its magnitude and location, were compared to the focal heating in the MRTI. Additional experiments compared PAM with standard B-mode ultrasound imaging and tested the feasibility of the system to map cavitation activity produced during low-power (5 W) burst sonications in a channel filled with a microbubble ultrasound contrast agent. Results: When inertial cavitation was evident, localized activity was present in PAM and a marked increase in heating was observed in MRTI. The location of the cavitation activity and heating agreed on average after registration of the two imaging modalities; the distance between the maximum cavitation activity and focal heating was −3.4 ± 2.1 mm and −0.1 ± 3.3 mm in the axial and transverse ultrasound array directions, respectively. Distortions and other MRI issues introduced small uncertainties in the PAM/MRTI registration. Although there was substantial variation, a nonlinear relationship between the average intensity of the cavitation maps, which was relatively constant during sonication, and the peak temperature rise was evident. A fit to the data to an exponential had a correlation coefficient (R2) of 0.62. The system was also found to be capable of visualizing cavitation activity with B-mode imaging and of passively mapping cavitation activity transcranially during cavitation-enhanced heating and during low-power sonication with an ultrasound contrast agent. Conclusions: The authors have demonstrated the feasibility of integrating an ultrasound imaging array into an MRgFUS system to simultaneously map localized cavitation activity and temperature. The authors anticipate that this integrated approach can be utilized to develop controllers for cavitation-enhanced ablation and facilitate the optimization and development of this and other ultrasound therapies. The integrated system may also provide a useful tool to study the bioeffects of acoustic cavitation. PMID:24320468

  16. Integrated ultrasound and magnetic resonance imaging for simultaneous temperature and cavitation monitoring during focused ultrasound therapies.

    PubMed

    Arvanitis, Costas D; McDannold, Nathan

    2013-11-01

    Ultrasound can be used to noninvasively produce different bioeffects via viscous heating, acoustic cavitation, or their combination, and these effects can be exploited to develop a wide range of therapies for cancer and other disorders. In order to accurately localize and control these different effects, imaging methods are desired that can map both temperature changes and cavitation activity. To address these needs, the authors integrated an ultrasound imaging array into an MRI-guided focused ultrasound (MRgFUS) system to simultaneously visualize thermal and mechanical effects via passive acoustic mapping (PAM) and MR temperature imaging (MRTI), respectively. The system was tested with an MRgFUS system developed for transcranial sonication for brain tumor ablation in experiments with a tissue mimicking phantom and a phantom-filled ex vivo macaque skull. In experiments on cavitation-enhanced heating, 10 s continuous wave sonications were applied at increasing power levels (30-110 W) until broadband acoustic emissions (a signature for inertial cavitation) were evident. The presence or lack of signal in the PAM, as well as its magnitude and location, were compared to the focal heating in the MRTI. Additional experiments compared PAM with standard B-mode ultrasound imaging and tested the feasibility of the system to map cavitation activity produced during low-power (5 W) burst sonications in a channel filled with a microbubble ultrasound contrast agent. When inertial cavitation was evident, localized activity was present in PAM and a marked increase in heating was observed in MRTI. The location of the cavitation activity and heating agreed on average after registration of the two imaging modalities; the distance between the maximum cavitation activity and focal heating was -3.4 ± 2.1 mm and -0.1 ± 3.3 mm in the axial and transverse ultrasound array directions, respectively. Distortions and other MRI issues introduced small uncertainties in the PAM∕MRTI registration. Although there was substantial variation, a nonlinear relationship between the average intensity of the cavitation maps, which was relatively constant during sonication, and the peak temperature rise was evident. A fit to the data to an exponential had a correlation coefficient (R(2)) of 0.62. The system was also found to be capable of visualizing cavitation activity with B-mode imaging and of passively mapping cavitation activity transcranially during cavitation-enhanced heating and during low-power sonication with an ultrasound contrast agent. The authors have demonstrated the feasibility of integrating an ultrasound imaging array into an MRgFUS system to simultaneously map localized cavitation activity and temperature. The authors anticipate that this integrated approach can be utilized to develop controllers for cavitation-enhanced ablation and facilitate the optimization and development of this and other ultrasound therapies. The integrated system may also provide a useful tool to study the bioeffects of acoustic cavitation.

  17. Endoscopic ultrasound-guided transmural drainage of postoperative pancreatic collections.

    PubMed

    Tilara, Amy; Gerdes, Hans; Allen, Peter; Jarnagin, William; Kingham, Peter; Fong, Yuman; DeMatteo, Ronald; D'Angelica, Michael; Schattner, Mark

    2014-01-01

    Pancreatic leak is a major cause of morbidity after pancreatectomy. Traditionally, peripancreatic fluid collections have been managed by percutaneous or operative drainage. Data for endoscopic ultrasound (EUS)-guided drainage of postoperative fluid collections are limited. Here we report on the safety, efficacy, and timing of EUS-guided drainage of postoperative peripancreatic collections. This is a retrospective review of 31 patients who underwent EUS-guided drainage of fluid collections after pancreatic resection. Technical success was defined as successful transgastric deployment of at least one double pigtail plastic stent. Clinical success was defined as resolution of the fluid collection on follow-up CT scan and resolution of symptoms. Early drainage was defined as initial transmural stent placement within 30 days after surgery. Endoscopic ultrasound-guided drainage was performed effectively with a technical success rate of 100%. Clinical success was achieved in 29 of 31 patients (93%). Nineteen of the 29 patients (65%) had complete resolution of their symptoms and collection with the first endoscopic procedure. Repeat drainage procedures, including some with necrosectomy, were required in the remaining 10 patients, with eventual resolution of collection and symptoms. Two patients who did not achieve durable clinical success required percutaneous drainage by interventional radiology. Seventeen (55%) of 31 patients had successful early drainage completed within 30 days of their operation. Endoscopic ultrasound-guided drainage of fluid collections after pancreatic resection is safe and effective. Early drainage (<30 days) of postoperative pancreatic fluid collections was not associated with increased complications in this series. Copyright © 2014 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  18. Pocket ultrasound device as a complement to physical examination for ascites evaluation and guided paracentesis.

    PubMed

    Keil-Ríos, Daniel; Terrazas-Solís, Hiram; González-Garay, Alejandro; Sánchez-Ávila, Juan Francisco; García-Juárez, Ignacio

    2016-04-01

    The pocket ultrasound device (PUD) is a new tool that may be of use in the early detection of ascites. Abdominal ultrasound-guided paracentesis has been reported to decrease the rate of complications due to the procedure, but must be performed in a healthcare setting; this new tool may be a useful on an ambulatory basis. The aim of this study was to determine the diagnostic usefulness of the PUD in the diagnosis of ascites and the safety of guided paracentesis. We conducted a retrospective study that included adult patients suspected of having ascites and in whom an evaluation was performed with the PUD to identify it. Concordance with abdominal ultrasound (AUS) was determined with the Kappa coefficient. Sensitivity (Se), specificity (Sp) and likelihood ratios (LR) were determined and compared with physical examination, AUS, computed tomography and procurement of fluid by paracentesis. Complications resulting from the guided paracentesis were analyzed. 89 participants were included and 40 underwent a paracentesis. The PUD for ascites detection had 95.8 % Se, 81.8 % Sp, 5.27 +LR and 0.05 -LR. It had a concordance with AUS of 0.781 (p < 0.001). Technical problems during the guided paracentesis were present in only two participants (5 %) and three patients (7.5 %) developed minor complications that required no further intervention. There were no severe complications or deaths. This study suggests that the PUD is a reliable tool for ascites detection as a complement to physical examination and appears to be a safe method to perform guided paracentesis.

  19. In-Plane Ultrasound-Guided Knee Injection Through a Lateral Suprapatellar Approach: A Safe Technique.

    PubMed

    Chagas-Neto, Francisco A; Taneja, Atul K; Gregio-Junior, Everaldo; Nogueira-Barbosa, Marcello H

    2017-06-01

    This study aims to describe a technique for in-plane ultrasound-guided knee arthrography through a lateral suprapatellar approach, reporting its accuracy and related complications. A retrospective search was performed for computed tomography and magnetic resonance reports from June 2013 through June 2015. Imaging studies, puncture descriptions, and guided-procedure images were reviewed along with clinical and surgical history. A fellowship-trained musculoskeletal radiologist performed all procedures under sterile technique and ultrasound guidance with the probe in oblique position on the lateral suprapatellar recess after local anesthesia with the patient on dorsal decubitus, hip in neutral rotation, and 30 to 45 degrees of knee flexion. A total of 86 consecutive subjects were evaluated (mean, 55 years). All subjects underwent intra-articular injection of contrast, which was successfully reached in the first attempt in 94.2% of the procedures (81/86), and in the second attempt in 5.8% (5/86) after needle repositioning without a second puncture. There were no postprocedural reports of regional complications at the puncture site, such as significant pain, bleeding, or vascular lesions. Our study demonstrates that in-plane ultrasound-guided injection of the knee in semiflexion approaching the lateral suprapatellar recess is a safe and useful technique to administer intra-articular contrast solution, as an alternative method without radiation exposure.

  20. Ultrasound-Guided Regional Anesthesia in a Glucose-6-Phosphate Dehydrogenase (G6PD)-Deficient Geriatric Trauma Patient

    PubMed Central

    Födinger, Agnes M.; Kammerlander, Christian; Luger, Thomas J.

    2012-01-01

    Objective: Glucose-6-phosphate dehydrogenase (G6PD) deficiency is a genetic enzymatic disorder causing hemolytic anemia. Exposure to drugs is considered to be the most common cause of acute hemolysis in patients with G6PD deficiency. Experience with regional anesthesia, in particular peripheral nerve blocks, is rarely described in patients with G6PD deficiency, but is of great clinical interest. For this reason, we now report on the successful management of ultrasound-guided axillary brachial plexus block in a patient with geriatric G6PD deficiency. Case report: A female, 75-year-old geriatric trauma patient with G6PD deficiency and a fracture of the left forearm, was scheduled for osteosynthesis of the left forearm. For surgery regional anesthesia with ultrasound-guided axillary brachial plexus block with 30 mL bupivacaine 0.5% was established. Surgical operation und postoperative course were uneventful and with no signs of hemolysis. Conclusion: Ultrasound-guided axillary brachial plexus block with bupivacaine was a safe and effective technique in this patient with G6PD deficiency. Peripheral nerve block is a major analgesic approach and of great value for anesthesiologists and surgeons, especially in our aging and multimorbid society. PMID:23569708

  1. Delay and Standard Deviation Beamforming to Enhance Specular Reflections in Ultrasound Imaging.

    PubMed

    Bandaru, Raja Sekhar; Sornes, Anders Rasmus; Hermans, Jeroen; Samset, Eigil; D'hooge, Jan

    2016-12-01

    Although interventional devices, such as needles, guide wires, and catheters, are best visualized by X-ray, real-time volumetric echography could offer an attractive alternative as it avoids ionizing radiation; it provides good soft tissue contrast, and it is mobile and relatively cheap. Unfortunately, as echography is traditionally used to image soft tissue and blood flow, the appearance of interventional devices in conventional ultrasound images remains relatively poor, which is a major obstacle toward ultrasound-guided interventions. The objective of this paper was therefore to enhance the appearance of interventional devices in ultrasound images. Thereto, a modified ultrasound beamforming process using conventional-focused transmit beams is proposed that exploits the properties of received signals containing specular reflections (as arising from these devices). This new beamforming approach referred to as delay and standard deviation beamforming (DASD) was quantitatively tested using simulated as well as experimental data using a linear array transducer. Furthermore, the influence of different imaging settings (i.e., transmit focus, imaging depth, and scan angle) on the obtained image contrast was evaluated. The study showed that the image contrast of specular regions improved by 5-30 dB using DASD beamforming compared with traditional delay and sum (DAS) beamforming. The highest gain in contrast was observed when the interventional device was tilted away from being orthogonal to the transmit beam, which is a major limitation in standard DAS imaging. As such, the proposed beamforming methodology can offer an improved visualization of interventional devices in the ultrasound image with potential implications for ultrasound-guided interventions.

  2. Ultrasound-guided breast-sparing surgery to improve cosmetic outcomes and quality of life. A prospective multicentre randomised controlled clinical trial comparing ultrasound-guided surgery to traditional palpation-guided surgery (COBALT trial)

    PubMed Central

    2011-01-01

    Background Breast-conserving surgery for breast cancer was developed as a method to preserve healthy breast tissue, thereby improving cosmetic outcomes. Thus far, the primary aim of breast-conserving surgery has been the achievement of tumour-free resection margins and prevention of local recurrence, whereas the cosmetic outcome has been considered less important. Large studies have reported poor cosmetic outcomes in 20-40% of patients after breast-conserving surgery, with the volume of the resected breast tissue being the major determinant. There is clear evidence for the efficacy of ultrasonography in the resection of nonpalpable tumours. Surgical resection of palpable breast cancer is performed with guidance by intra-operative palpation. These palpation-guided excisions often result in an unnecessarily wide resection of adjacent healthy breast tissue, while the rate of tumour-involved resection margins is still high. It is hypothesised that the use of intra-operative ultrasonography in the excision of palpable breast cancer will improve the ability to spare healthy breast tissue while maintaining or even improving the oncological margin status. The aim of this study is to compare ultrasound-guided surgery for palpable tumours with the standard palpation-guided surgery in terms of the extent of healthy breast tissue resection, the percentage of tumour-free margins, cosmetic outcomes and quality of life. Methods/design In this prospective multicentre randomised controlled clinical trial, 120 women who have been diagnosed with palpable early-stage (T1-2N0-1) primary invasive breast cancer and deemed suitable for breast-conserving surgery will be randomised between ultrasound-guided surgery and palpation-guided surgery. With this sample size, an expected 20% reduction of resected breast tissue and an 18% difference in tumour-free margins can be detected with a power of 80%. Secondary endpoints include cosmetic outcomes and quality of life. The rationale, study design and planned analyses are described. Conclusion The COBALT trial is a prospective, multicentre, randomised controlled study to assess the efficacy of ultrasound-guided breast-conserving surgery in patients with palpable early-stage primary invasive breast cancer in terms of the sparing of breast tissue, oncological margin status, cosmetic outcomes and quality of life. Trial Registration Number Netherlands Trial Register (NTR): NTR2579 PMID:21410949

  3. Comparison of a novel real-time SonixGPS needle-tracking ultrasound technique with traditional ultrasound for vascular access in a phantom gel model.

    PubMed

    Kopac, Daniel S; Chen, Jerry; Tang, Raymond; Sawka, Andrew; Vaghadia, Himat

    2013-09-01

    Ultrasound-guided percutaneous vascular access for endovascular procedures is well established in surgical practice. Despite this, rates of complications from venous and arterial access procedures remain a significant cause of morbidity. We hypothesized that the use of a new technique of vascular access using an ultrasound with a novel needle-guidance positioning system (GPS) would lead to improved success rates of vascular puncture for both in-plane and out-of-plane techniques compared with traditional ultrasound. A prospective, randomized crossover study of medical students from all years of medical school was conducted using a phantom gel model. Each medical student performed three ultrasound-guided punctures with each of the four modalities (in-plane no GPS, in-plane with GPS, out-of-plane no GPS, out-of-plane with GPS) for a total of 12 attempts. The success or failure was judged by the ability to aspirate a simulated blood solution from the model. The time to successful puncture was also recorded. A poststudy validated NASA Task Load Index workload questionnaire was conducted to assess the student's perceptions of the two different techniques. A total of 30 students completed the study. There was no significant difference seen in the mean times of vascular access for each of the modalities. Higher success rates for vascular access using the GPS for both the in-plane (94% vs 91%) and the out-of-plane (86% vs 70%) views were observed; however, this was not statistically significant. The students perceived the mental demand (median 12.0 vs 14.00; P = .035) and effort to be lower (mean 11.25 vs 14.00; P = .044) as well as the performance to be higher (mean 15.50 vs 14.00; P = .041) for the GPS vs the traditional ultrasound-guided technique. Students also perceived their ability to access vessels increased with the aid of the GPS (7.00 vs 6.50; P = .007). The majority of students expressed a preference for GPS (26/30, 87%) as opposed to the traditional counterpart. Use of the novel SonixGPS needle-tracking ultrasound system (UltraSonix, Richmond, BC, Canada) was not associated with a higher success rate of vascular puncture compared with the traditional ultrasound-guided technique. Assessment of mental task load significantly favored the use of the ultrasound GPS over the traditional ultrasound technique. Copyright © 2013 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

  4. Prostate tissue ablation with MRI guided transurethral therapeutic ultrasound and intraoperative assessment of the integrity of the neurovascular bundle

    NASA Astrophysics Data System (ADS)

    Sammet, Steffen; Partanen, Ari; Yousuf, Ambereen; Wardrip, Craig; Niekrasz, Marek; Antic, Tatjana; Razmaria, Aria; Sokka, Sham; Karczmar, Gregory; Oto, Aytekin

    2017-03-01

    OBJECTIVES: Evaluation of the precision of prostate tissue ablation with MRI guided therapeuticultrasound by intraoperative objective assessment of the neurovascular bundle in canines in-vivo. METHODS: In this ongoing IACUC approved study, eight male canines were scanned in a clinical 3T Achieva MRI scanner (Philips) before, during, and after ultrasound therapy with a prototype MR-guided ultrasound therapy system (Philips). The system includes a therapy console to plan treatment, to calculate real-time temperature maps, and to control ultrasound exposures with temperature feedback. Atransurethral ultrasound applicator with eight transducer elements was used to ablate canine prostate tissue in-vivo. Ablated prostate tissue volumes were compared to the prescribed target volumes to evaluate technical effectiveness. The ablated volumes determined by MRI (T1, T2, diffusion, dynamic contrast enhanced and 240 CEM43 thermal dose maps) were compared to H&E stained histological slides afterprostatectomy. Potential nerve damage of the neurovascular bundle was objectively assessed intraoperativelyduring prostatectomy with a CaverMap Surgical Aid nerve stimulator (Blue Torch Medical Technologies). RESULTS: Transurethral MRI -guided ultrasound therapy can effectively ablate canine prostate tissue invivo. Coronal MR-imaging confirmed the correct placement of the HIFU transducer. MRI temperature maps were acquired during HIFU treatment, and subsequently used for calculating thermal dose. Prescribed target volumes corresponded to the 240 CEM43 thermal dose maps during HIFU treatment in all canines. Ablated volumes on high resolution anatomical, diffusion weighted, and contrast enhanced MR images matched corresponding histological slides after prostatectomy. MRI guidance with realtime temperature monitoring showed no damage to surrounding tissues, especially to the neurovascular bundle (assessed intra-operatively with a nerve stimulator) or to the rectum wall. CONCLUSIONS: Our study demonstrates the effectiveness and precision of transurethral ultrasound ablation of prostatic tissue in canines with MRI monitoring and guidance. The canine prostate is an excellent model for the human prostate with similar anatomical characteristics and diseases. MRI guidance with real-time, intraoperative temperature monitoring reduces the risk of damaging critical surrounding anatomical structures in ultrasound therapy of the prostate.

  5. Ultrasound description of Pecs II (modified Pecs I): a novel approach to breast surgery.

    PubMed

    Blanco, R; Fajardo, M; Parras Maldonado, T

    2012-11-01

    The Pecs block (pectoral nerves block) is an easy and reliable superficial block inspired by the infraclavicular block approach and the transversus abdominis plane blocks. Once the pectoralis muscles are located under the clavicle the space between the two muscles is dissected to reach the lateral pectoral and the medial pectoral nerves. The main indications are breast expanders and subpectoral prosthesis where the distension of these muscles is extremely painful. A second version of the Pecs block is described, called "modified Pecs block" or Pecs block type II. This novel approach aims to block at least the pectoral nerves, the intercostobrachial, intercostals III-IV-V-VI and the long thoracic nerve. These nerves need to be blocked to provide complete analgesia during breast surgery, and it is an alternative or a rescue block if paravertebral blocks and thoracic epidurals failed. This block has been used in our unit in the past year for the Pecs I indications described, and in addition for, tumorectomies, wide excisions, and axillary clearances. The ultrasound sequence to perform this block is shown, together with simple X-ray dye images and gadolinium MRI images to understand the spread and pathways that can explain the benefit of this novel approach. Copyright © 2012 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Published by Elsevier España. All rights reserved.

  6. Abdominal muscle response to a simulated weight-bearing task by elite Australian Rules football players.

    PubMed

    Hyde, Jodie; Stanton, Warren R; Hides, Julie A

    2012-02-01

    The aim of this study was to examine the automatic recruitment of the deep abdominal muscles during a unilateral simulated weight-bearing task by elite Australian Rules football (AFL) players with and without low back pain (LBP). An observational cross-sectional study was conducted using ultrasound imaging to measure the thickness of the internal oblique (IO) and transversus abdominis (TrA) muscles. Thirty-seven elite male AFL players participated. Repeated measures factors included 'force level' (rest, 25% and 45% of body weight), 'leg' (dominant or non-dominant kicking leg) and 'side' (ultrasound side ipsilateral or contralateral to the leg used for the weight-bearing task). The dependent variables were thickness of the IO and TrA muscles. The results of this study showed that thickness of the IO (p<.0001) and TrA (p<.0001) muscles increased in response to 'force level'. During the task, the thickness of the IO muscle on the contralateral side of the trunk relative to the leg being tested, increased more in participants with current LBP (p=.034). This pattern was more distinct on the non-dominant kicking leg. Altered abdominal muscle recruitment in elite athletes with low back pain may be an attempt by the central nervous system (CNS) to compensate for inadequate lumbo-pelvic stability. Copyright © 2011 Elsevier B.V. All rights reserved.

  7. Ultrasound-Guided Abrams Pleural Biopsy vs CT-Guided Tru-Cut Pleural Biopsy in Malignant Pleural Disease, a 3-Year Follow-up Study.

    PubMed

    Sivakumar, Parthipan; Jayaram, Deepak; Rao, Deepak; Dhileepan, Vignesh; Ahmed, Irfan; Ahmed, Liju

    2016-12-01

    Conventional Abrams biopsy shows low sensitivity in suspected malignant pleural disease. There are limited data on the improvement in sensitivity by adding in image guidance. This retrospective study compares the diagnostic sensitivity of Abrams biopsy using ultrasound guidance with CT-guided Tru-Cut biopsy in suspected malignant pleural disease. Data were collected from 2006 to 2012 of patients who underwent image-guided biopsies for suspected non-tuberculous pleural disease. Data were collected on the result of the initial biopsy and final patient diagnosis as of June 2015. Sixty-three patients underwent image-guided Abrams biopsy and 29 underwent CT-guided Tru-Cut biopsies. The sensitivity of Abrams was 71.43 % compared to 75 % in the CT-guided Tru-Cut group. Specificity was 100 % in both groups. Image-guided Abrams biopsies demonstrate comparable diagnostic sensitivity in malignant pleural disease to CT-guided Tru-Cut biopsy.

  8. High-intensity focused ultrasound (HIFU) array system for image-guided ablative therapy (IGAT)

    NASA Astrophysics Data System (ADS)

    Kaczkowski, Peter J.; Keilman, George W.; Cunitz, Bryan W.; Martin, Roy W.; Vaezy, Shahram; Crum, Lawrence A.

    2003-06-01

    Recent interest in using High Intensity Focused Ultrasound (HIFU) for surgical applications such as hemostasis and tissue necrosis has stimulated the development of image-guided systems for non-invasive HIFU therapy. Seeking an all-ultrasound therapeutic modality, we have developed a clinical HIFU system comprising an integrated applicator that permits precisely registered HIFU therapy delivery and high quality ultrasound imaging using two separate arrays, a multi-channel signal generator and RF amplifier system, and a software program that provides the clinician with a graphical overlay of the ultrasound image and therapeutic protocol controls. Electronic phasing of a 32 element 2 MHz HIFU annular array allows adjusting the focus within the range of about 4 to 12 cm from the face. A central opening in the HIFU transducer permits mounting a commercial medical imaging scanhead (ATL P7-4) that is held in place within a special housing. This mechanical fixture ensures precise coaxial registration between the HIFU transducer and the image plane of the imaging probe. Recent enhancements include development of an acoustic lens using numerical simulations for use with a 5-element array. Our image-guided therapy system is very flexible and enables exploration of a variety of new HIFU therapy delivery and monitoring approaches in the search for safe, effective, and efficient treatment protocols.

  9. Ultrasound-guided interventional therapy for recurrent ovarian chocolate cysts.

    PubMed

    Wang, Lu-Lu; Dong, Xiao-Qiu; Shao, Xiao-Hui; Wang, Si-Ming

    2011-10-01

    The aim of this study was to determine the effectiveness of ultrasound-guided interventional therapy in the treatment of postoperative recurrent chocolate cysts. The 198 patients enrolled in this study were divided into three groups. In group 1, the saline washing group, the cavity of the cyst was washed thoroughly with warm saline. In group 2, the ethanol short-time retention group, after washing with saline, the cyst was injected with 95% ethanol with a volume of half of the fluid aspirated from the cyst. Ten minutes later, the rest of the ethanol was aspirated. In group 3, the ethanol retention group, the procedures were the same as with the ethanol short-time retention group, except that 95% of the ethanol was retained in the cyst. An ultrasound examination was performed in the third, sixth and 12th months after therapy. The chocolate cyst cure rate was significantly higher in the ethanol retention group (96%, 66/69) than in the ethanol short-time retention group (82%, 56/68) and no case was cured in the first group (saline washing). We conclude that ultrasound-guided injection and 95% ethanol retention are an effective therapy for the treatment of postoperative recurrent chocolate cysts. Copyright © 2011 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  10. Ultrasound-guided injection for plantar fasciitis: A brief review

    PubMed Central

    Nair, AS; Sahoo, RK

    2016-01-01

    Plantar fasciitis (PF) is a distressing condition experienced by many patients. Although self-limiting, it tends to become a chronic ailment if the precipitating factors are not addressed. One of the modality of treating PF is intra-lesional corticosteroid injection. This was done using palpation technique earlier but nowadays many specialists use ultrasound (US) imaging as a guide to give injection accurately instead of inadvertently damaging the plantar fascia or injecting into surrounding soft tissue, both of which can have serious implications. We did a literature search in Medline, Scopus, and Embase databases to find out articles describing US-guided corticosteroid injection for treating PF and whether guided injection was effective than injection given by palpation. PMID:27833490

  11. High-frequency ultrasound imaging for breast cancer biopsy guidance

    PubMed Central

    Cummins, Thomas; Yoon, Changhan; Choi, Hojong; Eliahoo, Payam; Kim, Hyung Ham; Yamashita, Mary W.; Hovanessian-Larsen, Linda J.; Lang, Julie E.; Sener, Stephen F.; Vallone, John; Martin, Sue E.; Kirk Shung, K.

    2015-01-01

    Abstract. Image-guided core needle biopsy is the current gold standard for breast cancer diagnosis. Microcalcifications, an important radiographic finding on mammography suggestive of early breast cancer such as ductal carcinoma in situ, are usually biopsied under stereotactic guidance. This procedure, however, is uncomfortable for patients and requires the use of ionizing radiation. It would be preferable to biopsy microcalcifications under ultrasound guidance since it is a faster procedure, more comfortable for the patient, and requires no radiation. However, microcalcifications cannot reliably be detected with the current standard ultrasound imaging systems. This study is motivated by the clinical need for real-time high-resolution ultrasound imaging of microcalcifications, so that biopsies can be accurately performed under ultrasound guidance. We have investigated how high-frequency ultrasound imaging can enable visualization of microstructures in ex vivo breast tissue biopsy samples. We generated B-mode images of breast tissue and applied the Nakagami filtering technique to help refine image output so that microcalcifications could be better assessed during ultrasound-guided core biopsies. We describe the preliminary clinical results of high-frequency ultrasound imaging of ex vivo breast biopsy tissue with microcalcifications and without Nakagami filtering and the correlation of these images with the pathology examination by hematoxylin and eosin stain and whole slide digital scanning. PMID:26693167

  12. A Guide to Analysing Tongue Motion from Ultrasound Images

    ERIC Educational Resources Information Center

    Stone, Maureen

    2005-01-01

    This paper is meant to be an introduction to and general reference for ultrasound imaging for new and moderately experienced users of the instrument. The paper consists of eight sections. The first explains how ultrasound works, including beam properties, scan types and machine features. The second section discusses image quality, including the…

  13. Large asymmetric hypertrophy of rectus abdominis muscle in professional tennis players.

    PubMed

    Sanchis-Moysi, Joaquin; Idoate, Fernando; Dorado, Cecilia; Alayón, Santiago; Calbet, Jose A L

    2010-12-31

    To determine the volume and degree of asymmetry of the musculus rectus abdominis (RA) in professional tennis players. The volume of the RA was determined using magnetic resonance imaging (MRI) in 8 professional male tennis players and 6 non-active male control subjects. Tennis players had 58% greater RA volume than controls (P = 0.01), due to hypertrophy of both the dominant (34% greater volume, P = 0.02) and non-dominant (82% greater volume, P = 0.01) sides, after accounting for age, the length of the RA muscle and body mass index (BMI) as covariates. In tennis players, there was a marked asymmetry in the development of the RA, which volume was 35% greater in the non-dominant compared to the dominant side (P<0.001). In contrast, no side-to-side difference in RA volume was observed in the controls (P = 0.75). The degree of side-to-side asymmetry increased linearly from the first lumbar disc to the pubic symphysis (r = 0.97, P<0.001). Professional tennis is associated with marked hypertrophy of the musculus rectus abdominis, which achieves a volume that is 58% greater than in non-active controls. Rectus abdominis hypertrophy is more marked in the non-dominant than in the dominant side, particularly in the more distal regions. Our study supports the concept that humans can differentially recruit both rectus abdominis but also the upper and lower regions of each muscle. It remains to be determined if this disequilibrium raises the risk of injury.

  14. Responses of intra-abdominal pressure and abdominal muscle activity during dynamic trunk loading in man.

    PubMed

    Cresswell, A G

    1993-01-01

    The purpose of this study was to determine and compare interactions between the abdominal musculature and intra-abdominal pressure (IAP) during controlled dynamic and static trunk muscle loading. Myoelectric activity was recorded in six subjects from the rectus abdominis, obliquus externus, obliquus internus, transversus abdominis and erector spinae muscles using surface and intra-muscular fine-wire electrodes. The IAP was recorded intra-gastrically. Trunk flexions and extensions were performed lying on one side on a swivel table. An adjustable brake provided different friction loading conditions, while adding weights to an unbraked swivel table afforded various levels of inertial loading. During trunk extensions at all friction loads, IAP was elevated (1.8-7.2 kPa) with concomitant activity in transversus abdominis and obliquus internus muscles--little or no activity was seen from rectus abdominis and obliquus externus muscles. For inertia loading during trunk extension, IAP levels were somewhat lower (1.8-5.6 kPa) and displayed a second peak when abdominal muscle activity occurred in the course of decelerating the movement. For single trunk flexions with friction loading, IAP was higher than that seen in extension conditions and increased with added resistance. For inertial loading during trunk flexion, IAP showed two peaks, the larger first peak matched peak forward acceleration and general abdominal muscle activation, while the second corresponded to peak deceleration and was accompanied by activity in transversus abdominis and erector spinae muscles. It was apparent that different loading strategies produced markedly different patterns of response in both trunk musculature and intra-abdominal pressure.

  15. Four quadrant transversus abdominis plane block and continuous transversus abdominis plane analgesia: a 3-year prospective audit in 124 patients.

    PubMed

    Niraj, G; Kelkar, Aditi; Hart, Elaine; Kaushik, Vipul; Fleet, Danny; Jameson, John

    2015-11-01

    Transversus abdominis plane (TAP) blocks have been reported to be an effective method of providing analgesia after abdominal surgery. To perform a prospective audit on the effectiveness of a novel technique of providing continuous transversus abdominis plane (TAP) analgesia in patients undergoing emergency and elective abdominal surgery. Prospective single center audit over a 3-year period. University hospital. One hundred twenty-four American Society of Anesthesiologists I to IV adult patients presenting for elective as well as emergency abdominal surgery in whom epidural analgesia was contraindicated or refused. Four quadrant TAP blocks and continuous TAP analgesia. Numerical rating scale pain scores at rest and on coughing, nausea scores, satisfaction scores, complications, frequency of analgesia failure, therapeutic failure with continuous TAP analgesia and opioid consumption. One hundred twenty-four patients who received continuous TAP analgesia were audited. This included 34 patients for elective open surgery, 36 patients for emergency laparotomy, and 54 patients who underwent elective laparoscopic colorectal surgery. Surgical incision was within the dermatomal limit of the block in 70% of the patients (88/124). Therapeutic failure with the technique was 10%. Frequency of analgesic failure over the 48-hour period was none in 39% and below 5 episodes in 57%. Four quadrant transversus abdominis plane blocks and continuous TAP analgesia is an effective technique for providing postoperative analgesia after abdominal surgery. It has the potential to be used as a sole analgesic technique when the surgical incision is within its dermatomal limit. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Body Mass Normalization for Lateral Abdominal Muscle Thickness Measurements in Adolescent Athletes.

    PubMed

    Linek, Pawel

    2017-09-01

    To determine the value of allometric parameters for ultrasound measurements of the oblique external (OE), oblique internal (OI), and transversus abdominis (TrA) muscles in adolescent athletes. The allometric parameter is the slope of the linear regression line between the log-transformed body mass and log-transformed muscle size measurement. The study included 114 male adolescent football players between the ages of 10 and 19 years. All individuals with no surgical procedures performed on the trunk area and who had played a sport for at least 2 years were included. A real-time B-mode ultrasound scanner with a linear array transducer was used to obtain images of the lateral abdominal muscles from both sides of the body. A stabilometric platform was used to assess the body mass value. The correlations between body mass and the OE, OI, and TrA muscle thicknesses were r = 0.73, r = 0.79, and r = 0.64, respectively (in all cases, P < .0001). The allometric parameters were 0.77 for the OE, 0.67 for the OI, and 0.61 for the TrA. Using these parameters, no significant correlations were found between body mass and the allometric-scaled thickness of the lateral abdominal muscles. Significant positive correlations exist between body mass and lateral abdominal muscle thickness in adolescent athletes. Therefore, it is reasonable to advise that the values of the allometric parameters for the OE, OI, and TrA muscles obtained in this study should be used, and the allometric-scaled thicknesses of those muscles should be analyzed in future research on adolescent athletes. © 2017 by the American Institute of Ultrasound in Medicine.

  17. Reconstruction of the pelvic floor and the vagina after total pelvic exenteration using the transverse musculocutaneous gracilis flap.

    PubMed

    Kaartinen, Ilkka S; Vuento, Maarit H; Hyöty, Marja K; Kallio, Jukka; Kuokkanen, Hannu O

    2015-01-01

    Total pelvic exenteration (TPE) is a rare operation in which the pelvic contents are removed entirely. Several options for pelvic floor and vaginal reconstruction have been described including transverse rectus abdominis musculocutaneous (TRAM) or deep inferior epigastric perforator (DIEP) flaps. The transverse musculocutaneous gracilis (TMG) flap has been introduced for breast reconstruction as a free flap. We adopted the pedicled TMG flap for reconstructions after TPE. To the best of our knowledge, this is the first report of this method in the literature. Between November 2011 and February 2014, 12 patients underwent TPE and reconstruction with unilateral (six patients) or bilateral (six patients) pedicled TMG flaps. Five patients underwent vaginal reconstruction with bilateral TMG flaps. We describe the operative procedure and the outcome of the operation in these patients. The total mean operative times for TPE with or without vaginal reconstruction were 467 ± 12 and 386 ± 59 min, respectively. The TMG flaps had enough vascular tissue and mobility for reconstructing the TPE defects. There was distal edge necrosis in one out of 18 flaps, while the rest survived completely. During the follow-up, complete wound healing with no signs of weakening of the pelvic floor was observed in all cases. Soft-tissue reconstructions are needed to reduce complications associated with TPE, to secure the pelvic floor and to reconstruct the vagina in select patients. The TMG flap is a logical flap choice that does not lead to functional deficits, complicate the abdominal ostomies or weaken the abdominal wall. It reduces the length of operation compared to that of abdominal flaps. IV, therapeutic. Copyright © 2014 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  18. Muscle activity during the active straight leg raise (ASLR), and the effects of a pelvic belt on the ASLR and on treadmill walking.

    PubMed

    Hu, Hai; Meijer, Onno G; van Dieën, Jaap H; Hodges, Paul W; Bruijn, Sjoerd M; Strijers, Rob L; Nanayakkara, Prabath W; van Royen, Barend J; Wu, Wenhua; Xia, Chun

    2010-02-10

    Women with pregnancy-related pelvic girdle pain (PPP), or athletes with groin pain, may have trouble with the active straight leg raise (ASLR), for which a pelvic belt can be beneficial. How the problems emerge, or how the belt works, remains insufficiently understood. We assessed muscle activity during ASLR, and how it changes with a pelvic belt. Healthy nulligravidae (N=17) performed the ASLR, and walked on a treadmill at increasing speeds, without and with a belt. Fine-wire electromyography (EMG) was used to record activity of the mm. psoas, iliacus and transversus abdominis, while other hip and trunk muscles were recorded with surface EMG. In ASLR, all muscles were active. In both tasks, transverse and oblique abdominal muscles were less active with the belt. In ASLR, there was more activity of the contralateral m. biceps femoris, and in treadmill walking of the m. gluteus maximus in conditions with a belt. For our interpretation, we take our starting point in the fact that hip flexors exert a forward rotating torque on the ilium. Apparently, the abdominal wall was active to prevent such forward rotation. If transverse and oblique abdominal muscles press the ilia against the sacrum (Snijders' "force closure"), the pelvis may move as one unit in the sagittal plane, and also contralateral hip extensor activity will stabilize the ipsilateral ilium. The fact that transverse and oblique abdominal muscles were less active in conditions with a pelvic belt suggests that the belt provides such "force closure", thus confirming Snijders' theory. Copyright 2009 Elsevier Ltd. All rights reserved.

  19. The effects of aquatic trunk exercise on gait and muscle activity in stroke patients: a randomized controlled pilot study.

    PubMed

    Park, Byoung-Sun; Noh, Ji-Woong; Kim, Mee-Young; Lee, Lim-Kyu; Yang, Seung-Min; Lee, Won-Deok; Shin, Yong-Sub; Kim, Ju-Hyun; Lee, Jeong-Uk; Kwak, Taek-Yong; Lee, Tae-Hyun; Kim, Ju-Young; Park, Jaehong; Kim, Junghwan

    2015-11-01

    [Purpose] The purpose of this study was to investigate the relationship between muscle activity and gait function following aquatic trunk exercise in hemiplegic stroke patients. [Subjects and Methods] This study's participants included thirteen hemiplegic patients (ten males and three females). The aquatic therapy consisted of administering concentrative aquatic therapy for four weeks in a therapeutic pool. Gait parameters were measured using a gait analysis system adjusted to each subject's comfortable walking speed. Electromyographic signals were measured for the rectus abdominis, external abdominal oblique, transversus abdominis/internal-abdominal oblique, and erector spine of each patients. [Results] The pre- and post-training performances of the transversus abdominis/internal-abdominal oblique were compared statistically. There was no statistical difference between the patients' pre- and post-training values of maximal voluntary isometric contraction of the rectus abdominis, but the external abdominal oblique values tended to improve. Furthermore, gait factors improved significantly in terms of walking speeds, walking cycles, affected-side stance phases, affected-stride lengths, and stance-phase symmetry indices, respectively. [Conclusion] These results suggest that the trunk exercise during aquatic therapy may in part contribute to clinically relevant improvements in muscle activities and gait parameters.

  20. The effects of aquatic trunk exercise on gait and muscle activity in stroke patients: a randomized controlled pilot study

    PubMed Central

    Park, Byoung-Sun; Noh, Ji-Woong; Kim, Mee-Young; Lee, Lim-Kyu; Yang, Seung-Min; Lee, Won-Deok; Shin, Yong-Sub; Kim, Ju-Hyun; Lee, Jeong-Uk; Kwak, Taek-Yong; Lee, Tae-Hyun; Kim, Ju-Young; Park, Jaehong; Kim, Junghwan

    2015-01-01

    [Purpose] The purpose of this study was to investigate the relationship between muscle activity and gait function following aquatic trunk exercise in hemiplegic stroke patients. [Subjects and Methods] This study’s participants included thirteen hemiplegic patients (ten males and three females). The aquatic therapy consisted of administering concentrative aquatic therapy for four weeks in a therapeutic pool. Gait parameters were measured using a gait analysis system adjusted to each subject’s comfortable walking speed. Electromyographic signals were measured for the rectus abdominis, external abdominal oblique, transversus abdominis/internal-abdominal oblique, and erector spine of each patients. [Results] The pre- and post-training performances of the transversus abdominis/internal-abdominal oblique were compared statistically. There was no statistical difference between the patients’ pre- and post-training values of maximal voluntary isometric contraction of the rectus abdominis, but the external abdominal oblique values tended to improve. Furthermore, gait factors improved significantly in terms of walking speeds, walking cycles, affected-side stance phases, affected-stride lengths, and stance-phase symmetry indices, respectively. [Conclusion] These results suggest that the trunk exercise during aquatic therapy may in part contribute to clinically relevant improvements in muscle activities and gait parameters. PMID:26696736

  1. Core Muscle Activation in Suspension Training Exercises.

    PubMed

    Cugliari, Giovanni; Boccia, Gennaro

    2017-02-01

    A quantitative observational laboratory study was conducted to characterize and classify core training exercises executed in a suspension modality on the base of muscle activation. In a prospective single-group repeated measures design, seventeen active male participants performed four suspension exercises typically associated with core training (roll-out, bodysaw, pike and knee-tuck). Surface electromyographic signals were recorded from lower and upper parts of rectus abdominis, external oblique, internal oblique, lower and upper parts of erector spinae muscles using concentric bipolar electrodes. The average rectified values of electromyographic signals were normalized with respect to individual maximum voluntary isometric contraction of each muscle. Roll-out exercise showed the highest activation of rectus abdominis and oblique muscles compared to the other exercises. The rectus abdominis and external oblique reached an activation higher than 60% of the maximal voluntary contraction (or very close to that threshold, 55%) in roll-out and bodysaw exercises. Findings from this study allow the selection of suspension core training exercises on the basis of quantitative information about the activation of muscles of interest. Roll-out and bodysaw exercises can be considered as suitable for strength training of rectus abdominis and external oblique muscles.

  2. Line fiducial material and thickness considerations for ultrasound calibration

    NASA Astrophysics Data System (ADS)

    Ameri, Golafsoun; McLeod, A. J.; Baxter, John S. H.; Chen, Elvis C. S.; Peters, Terry M.

    2015-03-01

    Ultrasound calibration is a necessary procedure in many image-guided interventions, relating the position of tools and anatomical structures in the ultrasound image to a common coordinate system. This is a necessary component of augmented reality environments in image-guided interventions as it allows for a 3D visualization where other surgical tools outside the imaging plane can be found. Accuracy of ultrasound calibration fundamentally affects the total accuracy of this interventional guidance system. Many ultrasound calibration procedures have been proposed based on a variety of phantom materials and geometries. These differences lead to differences in representation of the phantom on the ultrasound image which subsequently affect the ability to accurately and automatically segment the phantom. For example, taut wires are commonly used as line fiducials in ultrasound calibration. However, at large depths or oblique angles, the fiducials appear blurred and smeared in ultrasound images making it hard to localize their cross-section with the ultrasound image plane. Intuitively, larger diameter phantoms with lower echogenicity are more accurately segmented in ultrasound images in comparison to highly reflective thin phantoms. In this work, an evaluation of a variety of calibration phantoms with different geometrical and material properties for the phantomless calibration procedure was performed. The phantoms used in this study include braided wire, plastic straws, and polyvinyl alcohol cryogel tubes with different diameters. Conventional B-mode and synthetic aperture images of the phantoms at different positions were obtained. The phantoms were automatically segmented from the ultrasound images using an ellipse fitting algorithm, the centroid of which is subsequently used as a fiducial for calibration. Calibration accuracy was evaluated for these procedures based on the leave-one-out target registration error. It was shown that larger diameter phantoms with lower echogenicity are more accurately segmented in comparison to highly reflective thin phantoms. This improvement in segmentation accuracy leads to a lower fiducial localization error, which ultimately results in low target registration error. This would have a profound effect on calibration procedures and the feasibility of different calibration procedures in the context of image-guided procedures.

  3. Intraluminal laser atherectomy with ultrasound and electromagnetic guidance

    NASA Astrophysics Data System (ADS)

    Gregory, Kenton W.; Aretz, H. Thomas; Martinelli, Michael A.; LeDet, Earl G.; Hatch, G. F.; Gregg, Richard E.; Sedlacek, Tomas; Haase, Wayne C.

    1991-05-01

    The MagellanTM coronary laser atherectomy system is described. It uses high- resolution ultrasound imaging and electromagnetic sensing to provide real-time guidance and control of laser therapy in the coronary arteries. The system consists of a flexible catheter, an electromagnetic navigation antenna, a sensor signal processor and a computer for image processing and display. The small, flexible catheter combines an ultrasound transducer and laser delivery optics, aimed at the artery wall, and an electromagnetic receiving sensor. An extra-corporeal electromagnetic transmit antenna, in combination with catheter sensors, locates the position of the ultrasound and laser beams in the artery. Navigation and ultrasound data are processed electronically to produce real-time, transverse, and axial cross-section images of the artery wall at selected locations. By exploiting the ability of ultrasound to image beneath the surface of artery walls, it is possible to identify candidate treatment sites and perform safe radial laser debulking of atherosclerotic plaque with reduced danger of perforation. The utility of the system in plaque identification and ablation is demonstrated with imaging and experimental results.

  4. Endoscopic ultrasound guided drainage of pancreatic fluid collections: Assessment of the procedure, technical details and review of the literature

    PubMed Central

    Puri, Rajesh; Thandassery, Ragesh Babu; Alfadda, Abdulrahman A; Kaabi, Saad Al

    2015-01-01

    Endoscopic ultrasound (EUS) guided drainage of pancreatic fluid collections (PFC) has become increasingly popular and become first line management option in many centers. Use of therapeutic echoendoscopes has greatly increased the applicability of EUS guided transmural drainage. Drainage is indicated in symptomatic PFCs, PFC related infection, bleed, luminal obstruction, fistulization and biliary obstruction. EUS guided transmural drainage of PFCs is preferred in patients with non bulging lesions, portal hypertension, bleeding tendency and in those whom conventional drainage has failed. In the present decade significant progress has been made in minimally invasive endoscopic techniques. There are newer stent designs, access devices and techniques for more efficient drainage of PFCs. In this review, we discuss the EUS guided drainage of PFCs in acute pancreatitis. PMID:25901214

  5. Intra-Operative Vector Flow Imaging Using Ultrasound of the Ascending Aorta among 40 Patients with Normal, Stenotic and Replaced Aortic Valves.

    PubMed

    Hansen, Kristoffer Lindskov; Møller-Sørensen, Hasse; Kjaergaard, Jesper; Jensen, Maiken Brit; Lund, Jens Teglgaard; Pedersen, Mads Møller; Lange, Theis; Jensen, Jørgen Arendt; Nielsen, Michael Bachmann

    2016-10-01

    Stenosis of the aortic valve gives rise to more complex blood flows with increased velocities. The angle-independent vector flow ultrasound technique transverse oscillation was employed intra-operatively on the ascending aorta of (I) 20 patients with a healthy aortic valve and 20 patients with aortic stenosis before (IIa) and after (IIb) valve replacement. The results indicate that aortic stenosis increased flow complexity (p < 0.0001), induced systolic backflow (p < 0.003) and reduced systolic jet width (p < 0.0001). After valve replacement, the systolic backflow and jet width were normalized (p < 0.52 and p < 0.22), but flow complexity was not (p < 0.0001). Flow complexity (p < 0.0001), systolic jet width (p < 0.0001) and systolic backflow (p < 0.001) were associated with peak systolic velocity. The study found that aortic stenosis changes blood flow in the ascending aorta and valve replacement corrects some of these changes. Transverse oscillation may be useful for assessment of aortic stenosis and optimization of valve surgery. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  6. The Second American Society of Regional Anesthesia and Pain Medicine Evidence-Based Medicine Assessment of Ultrasound-Guided Regional Anesthesia: Executive Summary.

    PubMed

    Neal, Joseph M; Brull, Richard; Horn, Jean-Louis; Liu, Spencer S; McCartney, Colin J L; Perlas, Anahi; Salinas, Francis V; Tsui, Ban Chi-Ho

    2016-01-01

    In 2009 and again in 2012, the American Society of Regional Anesthesia and Pain Medicine assembled an expert panel to assess the evidence basis for ultrasound guidance as a nerve localization tool for regional anesthesia. The 2012 panel reviewed evidence from the first advisory but focused primarily on new information that had emerged since 2009. A new section was added regarding the accuracy and reliability of ultrasound for determining needle-to-nerve proximity. Jadad scores are used to rank study quality. Grades of recommendations consistent with their level of evidence are provided. The panel offers recommendations based on synthesis and analysis of literature related to (1) the technical capabilities of ultrasound equipment and its operators, (2) comparison of ultrasound to other methods of nerve localization with regard to block characteristics, (3) comparison of block techniques where ultrasound is the sole nerve localization modality, and (4) major complications. Assessment of evidence strength and recommendations are made for upper- and lower-extremity, truncal, neuraxial, and pediatric blocks. Scientific evidence from the past 5 years has clarified and strengthened our understanding of ultrasound-guided regional anesthesia as a nerve localization tool. High-level evidence supports ultrasound guidance contributing to superior characteristics with selected blocks, although absolute differences with the comparator technique are often relatively small (especially for upper-extremity blocks). The clinical meaningfulness of these differences is likely of variable importance to individual practitioners. The use of ultrasound significantly reduces the risk of local anesthetic systemic toxicity as well as the incidence and intensity of hemidiaphragmatic paresis, but has no significant effect on the incidence of postoperative neurologic symptoms. WHAT'S NEW IN THIS UPDATE?: This evidence-based assessment of ultrasound-guided regional anesthesia reviews findings from our 2010 publication and focuses on new meta-analyses, randomized controlled trials, and large case series published since 2009. New to this exercise is an in-depth analysis of the accuracy and reliability of ultrasound guidance for identifying needle-to-nerve relationships. This version no longer addresses ultrasound for interventional pain medicine procedures, because the growth of that field demands separate consideration. Since our 2010 publication, new information has either supported or strengthened our original conclusions. There is no evidence that ultrasound is inferior to alternative nerve localization methods.

  7. Quantitative diagnostic method for biceps long head tendinitis by using ultrasound.

    PubMed

    Huang, Shih-Wei; Wang, Wei-Te

    2013-01-01

    To investigate the feasibility of grayscale quantitative diagnostic method for biceps tendinitis and determine the cut-off points of a quantitative biceps ultrasound (US) method to diagnose biceps tendinitis. Design. Prospective cross-sectional case controlled study. Outpatient rehabilitation service. A total of 336 shoulder pain patients with suspected biceps tendinitis were recruited in this prospective observational study. The grayscale pixel data of the range of interest (ROI) were obtained for both the transverse and longitudinal views of the biceps US. A total of 136 patients were classified with biceps tendinitis, and 200 patients were classified as not having biceps tendinitis based on the diagnostic criteria. Based on the Youden index, the cut-off points were determined as 26.85 for the transverse view and 21.25 for the longitudinal view of the standard deviation (StdDev) of the ROI values, respectively. When the ROI evaluation of the US surpassed the cut-off point, the sensitivity was 68% and the specificity was 90% in the StdDev of the transverse view, and the sensitivity was 81% and the specificity was 73% in the StdDev of the longitudinal view to diagnose biceps tendinitis. For equivocal cases or inexperienced sonographers, our study provides a more objective method for diagnosing biceps tendinitis in shoulder pain patients.

  8. Endoscopic ultrasound-guided transesophageal thoracentesis for minimal pleural effusion.

    PubMed

    Rana, Surinder Singh; Sharma, Ravi; Gupta, Rajesh

    2018-06-19

    Pleural effusion is a common finding both in patients with benign and malignant diseases of pleura and lung with diagnostic thoracentesis establishing the diagnosis in the majority of cases. The diagnostic thoracentesis can be done either blindly or under the guidance of ultrasound or computed tomography. However, minimal pleural effusion is difficult to sample even under image guidance. Endoscopic ultrasound (EUS) is known to detect smaller volume of pleural effusion and, thus, can help in guiding thoracentesis. To analyze the safety and efficacy of EUS-guided diagnostic thoracentesis in patients with undiagnosed minimal pleural effusion retrospectively. Retrospective analysis of the data of patients with minimal pleural effusion, who underwent EUS-guided transesophageal diagnostic thoracentesis over last 2 years, was performed. Thirteen patients (11 male; mean age 46.7 ± 16.2 years) with undiagnosed minimal pleural effusion underwent successful EUS-guided transesophageal diagnostic thoracentesis using a 22-G needle. Seven (53%) patients had fever on presentation whereas two presented with cough and loss of appetite. Eight to 54 mL fluid was aspirated with an attempt to completely empty the pleural cavity. There were no complications of the procedure. EUS-guided diagnostic thoracentesis is a safe and effective alternative for evaluating patients with minimal pleural effusion.

  9. Focused ultrasound guided relocation of kidney stones.

    PubMed

    Abrol, Nitin; Kekre, Nitin S

    2015-01-01

    Complete removal of all fragments is the goal of any intervention for urinary stones. This is more important in lower pole stones where gravity and spatial orientation of lower pole infundibulum may hinder spontaneous passage of fragments. Various adjuvant therapies (inversion, diuresis, percussion, oral citrate, etc.) are described to enhance stone-free rate but are not widely accepted. Focused ultrasound-guided relocation of fragments is a recently described technique aimed at improving results of intervention for stone disease. Purpose of this review is to discuss development of this technology and its potential clinical applications. Pubmed search was made using key words "Focused ultrasound" and "kidney stone". All English language articles were reviewed by title. Relevant studies describing development and application of focused ultrasound in renal stones were selected for review. Focused ultrasound has proven its efficacy in successfully relocating up to 8 mm stone fragments in vitro and in pigs. Relocation is independent of stone composition. The latest model allows imaging and therapy with a single handheld probe facilitating its use by single operator. The acoustic energy delivered by the new prototype is even less than that used for extracorporeal shock wave lithotripsy. Therapeutic exposure has not caused thermal injury in pig kidneys. Focused ultrasound-guided relocation of stones is feasible. Though it is safe in application in pigs, technology is awaiting approval for clinical testing in human beings. This technology has many potential clinical applications in the management of stone disease.

  10. Ultrasound-guided intrasphincteric botulinum toxin injection relieves obstructive defecation due to Hirschsprung's disease and internal anal sphincter achalasia.

    PubMed

    Church, Joseph T; Gadepalli, Samir K; Talishinsky, Toghrul; Teitelbaum, Daniel H; Jarboe, Marcus D

    2017-01-01

    Chronic obstructive defecation can occur in patients with Hirschsprung Disease (HD) and internal anal sphincter (IAS) achalasia. Injection of Botulinum Toxin (BoTox) into the IAS can temporarily relieve obstructive defecation, but can be challenging when performed by tactile sense alone. We compared results of BoTox injections with and without ultrasound (US) guidance. We retrospectively reviewed BoTox injections into the IAS for obstructive defecation over 5years. Analyzed outcomes included short-term improvement, defined as resolution of enterocolitis, new ability to spontaneously defecate, and/or normalization of bowel movement frequency 2weeks post-operatively, as well as requirement of more definitive surgical therapy (myotomy/myomectomy, colectomy, colostomy, cecostomy/appendicostomy, and/or sacral nerve stimulator implantation). Outcomes were compared using t-test and Fisher's Exact test, with significance defined as p<0.05. Twelve patients who underwent BoTox injection were included, including 5 patients who underwent injections both with and without ultrasound. Ten underwent an ultrasound-guided injection (13 injection procedures), 5 of whom had HD. Seven underwent an injection without ultrasound guidance (17 injection procedures), 5 of whom had HD. Procedures performed with US resulted in greater short-term improvement (76% versus 65% without ultrasound) and less requirement of a definitive procedure for obstructive defecation (p<0.05). US-guided BoTox injection is safe and effective for obstructive defecation, and may decrease the need for a definitive operation. III. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Passive Markers for Tracking Surgical Instruments in Real-Time 3-D Ultrasound Imaging

    PubMed Central

    Stoll, Jeffrey; Ren, Hongliang; Dupont, Pierre E.

    2013-01-01

    A family of passive echogenic markers is presented by which the position and orientation of a surgical instrument can be determined in a 3-D ultrasound volume, using simple image processing. Markers are attached near the distal end of the instrument so that they appear in the ultrasound volume along with the instrument tip. They are detected and measured within the ultrasound image, thus requiring no external tracking device. This approach facilitates imaging instruments and tissue simultaneously in ultrasound-guided interventions. Marker-based estimates of instrument pose can be used in augmented reality displays or for image-based servoing. Design principles for marker shapes are presented that ensure imaging system and measurement uniqueness constraints are met. An error analysis is included that can be used to guide marker design and which also establishes a lower bound on measurement uncertainty. Finally, examples of marker measurement and tracking algorithms are presented along with experimental validation of the concepts. PMID:22042148

  12. Reproducibility of Ultrasound-Guided High Intensity Focused Ultrasound (HIFU) Thermal Lesions in Minimally-Invasive Brain Surgery

    NASA Astrophysics Data System (ADS)

    Zahedi, Sulmaz

    This study aims to prove the feasibility of using Ultrasound-Guided High Intensity Focused Ultrasound (USg-HIFU) to create thermal lesions in neurosurgical applications, allowing for precise ablation of brain tissue, while simultaneously providing real time imaging. To test the feasibility of the system, an optically transparent HIFU compatible tissue-mimicking phantom model was produced. USg-HIFU was then used for ablation of the phantom, with and without targets. Finally, ex vivo lamb brain tissue was imaged and ablated using the USg-HIFU system. Real-time ultrasound images and videos obtained throughout the ablation process showing clear lesion formation at the focal point of the HIFU transducer. Post-ablation gross and histopathology examinations were conducted to verify thermal and mechanical damage in the ex vivo lamb brain tissue. Finally, thermocouple readings were obtained, and HIFU field computer simulations were conducted to verify findings. Results of the study concluded reproducibility of USg-HIFU thermal lesions for neurosurgical applications.

  13. Ultrasound in Arthritis.

    PubMed

    Sudoł-Szopińska, Iwona; Schueller-Weidekamm, Claudia; Plagou, Athena; Teh, James

    2017-09-01

    Ultrasound is currently performed in everyday rheumatologic practice. It is used for early diagnosis, to monitor treatment results, and to diagnose remission. The spectrum of pathologies seen in arthritis with ultrasound includes early inflammatory features and associated complications. This article discusses the spectrum of ultrasound features of arthritides seen in rheumatoid arthritis and other connective tissue diseases in adults, such as Sjögren syndrome, lupus erythematosus, dermatomyositis, polymyositis, and juvenile idiopathic arthritis. Ultrasound findings in spondyloarthritis, osteoarthritis, and crystal-induced diseases are presented. Ultrasound-guided interventions in patients with arthritis are listed, and the advantages and disadvantages of ultrasound are discussed. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. High-flow vascular malformation treatment using ultrasound-guided laser combined with polidocanol sclerotherapy.

    PubMed

    Zhang, Yan; Zhou, Ping; Li, Lan; Li, Jia-le

    2015-07-01

    The current treatment for vascular malformations includes surgery, sclerotherapy, and embolization. However, each method has its limitations, such as recurrence, complications, scarring, and radiation exposure. Therefore, identifying an effective, minimally invasive treatment that reduces lesion recurrence is particularly important. We describe in detail a patient who received treatment with ultrasound-guided laser interruption of feeding vessels combined with polidocanol sclerotherapy after the recurrence of forearm high-flow vascular malformation.

  15. Simulators for training in ultrasound guided procedures.

    PubMed

    Farjad Sultan, Syed; Shorten, George; Iohom, Gabrielle

    2013-06-01

    The four major categories of skill sets associated with proficiency in ultrasound guided regional anaesthesia are 1) understanding device operations, 2) image optimization, 3) image interpretation and 4) visualization of needle insertion and injection of the local anesthetic solution. Of these, visualization of needle insertion and injection of local anaesthetic solution can be practiced using simulators and phantoms. This survey of existing simulators summarizes advantages and disadvantages of each. Current deficits pertain to the validation process.

  16. Ultrasound-guided peripheral nerve interventions for common pain disorders

    PubMed Central

    Krishna Prasad, B P; Joy, Binu; Raghavendra, Vijayakumar A; Toms, Ajith; George, Danny; Ray, Brijesh

    2018-01-01

    There are a number of common pain disorders that can be managed effectively by injections around or ablation of peripheral nerves. Ultrasound is a universally available imaging tool, is safe, cost-effective, and is excellent in imaging many peripheral nerves and guiding needles to the site of the nerves. This article aims to present an overview of indications and techniques of such procedures that can be effectively performed by a radiologist. PMID:29692534

  17. Ultrasound-Guided Percutaneous Drainage of Neonatal Pyometrocolpos Under Local Anesthesia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Algin, Oktay, E-mail: droktayalgin@gmail.com; Erdogan, Cuneyt; Kilic, Nizamettin

    2011-02-15

    Hydrometrocolpos is an uncommon congenital disorder with cystic dilatation of the vagina and uterus that occurs as a result of accumulated secretions from the reproductive tract due to distal genital tract obstruction. Secondary infection may also occur, resulting in pyometrocolpos, a potentially lethal disease. Immediate drainage of the cystic mass in patients determined to have pyometrocolpos is required to prevent or treat uropathy and septicemia until definitive corrective surgery can be performed. We report an unusual cause of obstructive uropathy in three infants: pyometrocolpos due to lower genital tract atresia. Ultrasound-guided percutaneous drainage of the pyometrocolpos resulted in dramatically improvedmore » clinical and laboratory findings in these patients. Ultrasound-guided percutaneous drainage under local anesthesia is a simple, minimally invasive, safe, and effective procedure that facilitates later successful corrective surgery and avoids the need for more complex drainage procedures.« less

  18. Randomized controlled study of the safety and efficacy of nitrous oxide-sedated endoscopic ultrasound-guided fine needle aspiration for digestive tract diseases.

    PubMed

    Wang, Cai-Xia; Wang, Jian; Chen, Yuan-Yuan; Wang, Jia-Ni; Yu, Xin; Yang, Feng; Sun, Si-Yu

    2016-12-14

    To evaluate the efficacy and safety of nitrous oxide-sedated endoscopic ultrasound-guided fine needle aspiration. Enrolled patients were divided randomly into an experimental group (inhalation of nitrous oxide) and a control group (inhalation of pure oxygen) and heart rate, blood oxygen saturation, blood pressure, electrocardiogram (ECG) changes, and the occurrence of complications were monitored and recorded. All patients and physicians completed satisfaction questionnaires about the examination and scored the process using a visual analog scale. There was no significant difference in heart rate, blood oxygen saturation, blood pressure, ECG changes, or complication rate between the two groups of patients ( P > 0.05). However, patient and physician satisfaction were both significantly higher in the nitrous oxide compared with the control group ( P < 0.05). Nitrous oxide-sedation is a safe and effective option for patients undergoing endoscopic ultrasound-guided fine needle aspiration.

  19. Regional lymph node staging in breast cancer: the increasing role of imaging and ultrasound-guided axillary lymph node fine needle aspiration.

    PubMed

    Mainiero, Martha B

    2010-09-01

    The status of axillary lymph nodes is a key prognostic indicator in patients with breast cancer and helps guide patient management. Sentinel lymph node biopsy is increasingly being used as a less morbid alternative to axillary lymph node dissection. However, when sentinel lymph node biopsy is positive, axillary dissection is typically performed for complete staging and local control. Axillary ultrasound and ultrasound-guided fine needle aspiration (USFNA) are useful for detecting axillary nodal metastasis preoperatively and can spare patients sentinel node biopsy, because those with positive cytology on USFNA can proceed directly to axillary dissection or neoadjuvant chemotherapy. Internal mammary nodes are not routinely evaluated, but when the appearance of these nodes is abnormal on imaging, further treatment or metastatic evaluation may be necessary. Copyright © 2010 Elsevier Inc. All rights reserved.

  20. Yield and complications in percutaneous renal biopsy. A comparison between ultrasound-guided gun-biopsy and manual techniques in native and transplant kidneys.

    PubMed

    Nyman, R S; Cappelen-Smith, J; al Suhaibani, H; Alfurayh, O; Shakweer, W; Akhtar, M

    1997-05-01

    To compare the yield and complications of ultrasound-guided gun-biopsy and manual Tru-Cut techniques in percutaneous renal biopsy. A total of 448 biopsies were reviewed. They comprised 124 manual and 131 gun-biopsies in native kidneys, and 111 manual and 82 gun-biopsies in transplant kidneys. The gun-biopsies were performed under real-time ultrasound (US) guidance. The manual technique used US mainly for marking the position of the kidney. There was a significantly higher diagnostic yield and fewer complications in the gun-biopsy group. A total of 8 major complications were found, all in the manual group. Provided that the operator is experienced in US scanning, a switch from the manual technique to real-time US-guided gun-biopsy will result in the improvement of diagnostic accuracy together with a reduced risk of complications.

  1. Ultrasound guided electrochemotherapy for the treatment of a clear cell thymoma in a cat

    PubMed Central

    Spugnini, Enrico Pierluigi; Menicagli, Francesco; Pettorali, Michela; Baldi, Alfonso

    2017-01-01

    A twelve-year-old male castrated domestic shorthair cat was presented for rapidly progressing respiratory distress. The cat was depressed, tachypneic and moderately responsive. Ultrasonography showed a mediastinal mass associated with a significant pleural effusion that needed tapping every five to seven days. Ultrasound guided biopsy yielded a diagnosis of clear cell thymoma upon histopathology. After complete staging procedures, the owner elected to treat the cat with electrochemotherapy (ECT) using systemic bleomycin. Two sessions of ultrasound guided ECT were performed at two week intervals with trains of biphasic electric pulses applied using needle electrodes until complete coverage of the area was achieved. The treatment was well tolerated and resulted in partial remission (PR). Additional sessions were performed on a monthly basis. The cat is still in PR after fourteen months. ECT resulted in improved local control and should be considered among the available adjuvant treatments in pets carrying visceral tumors. PMID:28331834

  2. Optimizing MR imaging-guided navigation for focused ultrasound interventions in the brain

    NASA Astrophysics Data System (ADS)

    Werner, B.; Martin, E.; Bauer, R.; O'Gorman, R.

    2017-03-01

    MR imaging during transcranial MR imaging-guided Focused Ultrasound surgery (tcMRIgFUS) is challenging due to the complex ultrasound transducer setup and the water bolus used for acoustic coupling. Achievable image quality in the tcMRIgFUS setup using the standard body coil is significantly inferior to current neuroradiologic standards. As a consequence, MR image guidance for precise navigation in functional neurosurgical interventions using tcMRIgFUS is basically limited to the acquisition of MR coordinates of salient landmarks such as the anterior and posterior commissure for aligning a stereotactic atlas. Here, we show how improved MR image quality provided by a custom built MR coil and optimized MR imaging sequences can support imaging-guided navigation for functional tcMRIgFUS neurosurgery by visualizing anatomical landmarks that can be integrated into the navigation process to accommodate for patient specific anatomy.

  3. Ergonomic task analysis of ultrasound-guided femoral nerve block: a pilot study.

    PubMed

    Ajmal, Muhammad; Power, Susan; Smith, Tim; Shorten, George D

    2011-02-01

    To apply ergonomic task analysis to the performance of ultrasound-guided (US-guided) femoral nerve block (FNB) in an acute hospital setting. Pilot prospective observational study. Orthopedic operating room of a regional trauma hospital. 15 anesthesiologists of various levels of experience in US-guided FNB (estimated minimum experience < 10 procedures; maximum about 50 procedures, and from basic trainees to consultants); and 15 patients (5 men and 10 women), aged 77 ± 15 (mean ± SD yrs) years. MEASUREMENTS/OBSERVATIONS: A data capture "tool", which was modified from one previously developed for ergonomic study of spinal anesthesia, was studied. Patient, operator, and heterogeneous environmental factors related to ergonomic performance of US-guided FNB were identified. The observation period started immediately before commencement of positioning the patient and ended on completion of perineural injection. Data were acquired using direct observations, photography, and application of a questionnaire. The quality of ergonomic performance was generally suboptimal and varied greatly among operators. Eight (experience < 10 procedures) of 15 operators excessively rotated their head, neck, and/or back to visualize the image on the ultrasound machine. Eight operators (experience < 10 procedures) performed the procedure with excessive thoracolumbar flexion. Performance of US-guided FNB presents ergonomic challenges and was suboptimal during most of the procedures observed. Formal training in US-guided peripheral nerve blockade should include reference to ergonomic factors. Copyright © 2011 Elsevier Inc. All rights reserved.

  4. Robotic active positioning for magnetic resonance-guided high-intensity focused ultrasound

    NASA Astrophysics Data System (ADS)

    Xiao, Xu; Huang, Zhihong; Volovick, Alexander; Melzer, Andreas

    2012-11-01

    Magnetic resonance (MR) guided High-intensity focused ultrasound (HIFU) is a noninvasive method producing thermal necrosis and cavitation at the position of tumors with high accuracy. Because the typical size of the high-intensity focused ultrasound focus are much smaller than the targeted tumor or other tissues, multiple sonications and focus repositioning become necessary for HIFU treatment. In order to reach a much wider range, manual repositioning or using MR compatible mechanical actuators could be used. The repositioning technique is a time consuming procedure because it needs a series of MR imaging to detect the transducer and markers preplaced on the mechanical devices. We combined an active tracking technique into the MR guided HIFU system. In this work, the robotic system used is the MR-compatible robotics from InnoMotion{trade mark, serif} (IBSMM, Engineering spol. s r.o. / Ltd, Czech) which is originally designed for MR-guided needle biopsy. The precision and positioning speed of the combined robotic HIFU system are evaluated in this study. Compared to the existing MR guided HIFU systems, the combined robotic system with active tracking techniques provides a potential that allows the HIFU treatment to operate in a larger spatial range and with a faster speed.

  5. Coherent perfect absorption mediated enhancement of transverse spin in a gap plasmon guide

    NASA Astrophysics Data System (ADS)

    Mukherjee, Samyobrata; Dutta Gupta, Subhasish

    2017-01-01

    We consider a symmetric gap plasmon guide (a folded Kretschmann configuration) supporting both symmetric and antisymmetric coupled surface plasmons. We calculate the transverse spin under illumination from both the sides like in coherent perfect absorption (CPA), whereby all the incident light can be absorbed to excite one of the modes of the structure. Significant enhancement in the transverse spin is shown to be possible when the CPA dip and the mode excitation are at the same frequency. The enhancement results from CPA-mediated total transfer of the incident light to either of the coupled modes and the associated large local fields. The effect is shown to be robust against small deviations from the symmetric structure. The transverse spin is localized in the structure since in the ambient dielectric there are only incident plane waves lacking any structure.

  6. Transversely bounded DFB lasers. [bounded distributed-feedback lasers

    NASA Technical Reports Server (NTRS)

    Elachi, C.; Evans, G.; Yeh, C.

    1975-01-01

    Bounded distributed-feedback (DFB) lasers are studied in detail. Threshold gain and field distribution for a number of configurations are derived and analyzed. More specifically, the thin-film guide, fiber, diffusion guide, and hollow channel with inhomogeneous-cladding DFB lasers are considered. Optimum points exist and must be used in DFB laser design. Different-modes feedback and the effects of the transverse boundaries are included. A number of applications are also discussed.

  7. Ultrasound-guided cable-free 13-gauge vacuum-assisted biopsy of non-mass breast lesions

    PubMed Central

    Seo, Jiwoon; Jang, Mijung; Yun, Bo La; Lee, Soo Hyun; Kim, Eun-Kyu; Kang, Eunyoung; Park, So Yeon; Moon, Woo Kyung; Choi, Hye Young; Kim, Bohyoung

    2017-01-01

    Purpose To compare the outcomes of ultrasound-guided core biopsy for non-mass breast lesions by the novel 13-gauge cable-free vacuum-assisted biopsy (VAB) and by the conventional 14-gauge semi-automated core needle biopsy (CCNB). Materials and methods Our institutional review board approved this prospective study, and all patients provided written informed consent. Among 1840 ultrasound-guided percutaneous biopsies performed from August 2013 to December 2014, 145 non-mass breast lesions with suspicious microcalcifications on mammography or corresponding magnetic resonance imaging finding were subjected to 13-gauge VAB or 14-gauge CCNB. We evaluated the technical success rates, average specimen numbers, and tissue sampling time. We also compared the results of percutaneous biopsy and final surgical pathologic diagnosis to analyze the rates of diagnostic upgrade or downgrade. Results Ultrasound-guided VAB successfully targeted and sampled all lesions, whereas CCNB failed to demonstrate calcification in four (10.3%) breast lesions with microcalcification on specimen mammography. The mean sampling time were 238.6 and 170.6 seconds for VAB and CCNB, respectively. No major complications were observed with either method. Ductal carcinoma in situ (DCIS) and atypical ductal hyperplasia (ADH) lesions were more frequently upgraded after CCNB (8/23 and 3/5, respectively) than after VAB (2/26 and 0/4, respectively P = 0.028). Conclusion Non-mass breast lesions were successfully and accurately biopsied using cable-free VAB. The underestimation rate of ultrasound-detected non-mass lesion was significantly lower with VAB than with CCNB. Trial registration CRiS KCT0002267. PMID:28628656

  8. Ultrasound-guided core needle biopsy in diagnosis of abdominal and pelvic neoplasm in pediatric patients.

    PubMed

    Wang, Hailing; Li, Fangxuan; Liu, Juntian; Zhang, Sheng

    2014-01-01

    Ultrasound-guided core needle biopsy of abdominal and pelvic masses in adults has gained tremendous popularity. However, the application of the same treatment in children is not as popular because of apprehensions regarding inadequate tissues for the biopsy and accidental puncture of vital organs. Data of the application of ultrasound-guided core needle biopsy in 105 pediatric patients with clinically or ultrasound-diagnosed abdominopelvic masses were reviewed. Diagnostic procedures were conducted in our institution from May 2011 to May 2013. The biopsies were conducted on 86 malignant lesions and 19 benign lesions. 86 malignant tumors comprised neuroblastomas (30 cases), hepatoblastomas (15 cases), nephroblastomas (11 cases), and primitive neuroectodermal tumors/malignant small round cells (6 cases). Among malignant tumor cases, only a pelvic primitive neuroectodermal tumor did not receive a pathological diagnosis. Therefore, the biopsy accuracy was 98.8 % in malignant tumor. However, the biopsies for one neuroblastomas and one malignant small round cell tumor were inadequate for cytogenetic analysis. Therefore, 96.5 % of the malignant tumor patients received complete diagnosis via biopsy. 19 benign tumors comprised mature teratoma (10 cases), hemangioendothelioma (3 cases), paraganglioma (2 cases), and infection (2 cases). The diagnostic accuracy for benign neoplasm was 100 %. Five patients experienced postoperative complications, including pain (2 patients), bleeding from the biopsy site (2 patients), and wound infection (1 patient). Ultrasound-guided core needle biopsy is an efficient, minimally invasive, accurate, and safe diagnostic method that can be applied in the management of abdominal or pelvic mass of pediatric patients.

  9. Use of the cumulative sum method (CUSUM) to assess the learning curves of ultrasound-guided continuous femoral nerve block.

    PubMed

    Kollmann-Camaiora, A; Brogly, N; Alsina, E; Gilsanz, F

    2017-10-01

    Although ultrasound is a basic competence for anaesthesia residents (AR) there is few data available on the learning process. This prospective observational study aims to assess the learning process of ultrasound-guided continuous femoral nerve block and to determine the number of procedures that a resident would need to perform in order to reach proficiency using the cumulative sum (CUSUM) method. We recruited 19 AR without previous experience. Learning curves were constructed using the CUSUM method for ultrasound-guided continuous femoral nerve block considering 2 success criteria: a decrease of pain score>2 in a [0-10] scale after 15minutes, and time required to perform it. We analyse data from 17 AR for a total of 237 ultrasound-guided continuous femoral nerve blocks. 8/17 AR became proficient for pain relief, however all the AR who did more than 12 blocks (8/8) became proficient. As for time of performance 5/17 of AR achieved the objective of 12minutes, however all the AR who did more than 20 blocks (4/4) achieved it. The number of procedures needed to achieve proficiency seems to be 12, however it takes more procedures to reduce performance time. The CUSUM methodology could be useful in training programs to allow early interventions in case of repeated failures, and develop competence-based curriculum. Copyright © 2017 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  10. Stiffness at shear-wave elastography and patient presentation predicts upgrade at surgery following an ultrasound-guided core biopsy diagnosis of ductal carcinoma in situ.

    PubMed

    Evans, A; Purdie, C A; Jordan, L; Macaskill, E J; Flynn, J; Vinnicombe, S

    2016-11-01

    The aim of this study is to establish predictors of invasion in lesions yielding an ultrasound-guided biopsy diagnosis of ductal carcinoma in situ (DCIS). Patients subjected to ultrasound-guided core biopsy yielding DCIS were studied. At shear-wave elastography (SWE) a threshold of 50 kPa was used for mean elasticity (Emean) to dichotomise the elasticity data between invasive and non-invasive masses. Data recorded included the mammographic and ultrasound features, the referral source, and grade of DCIS in the biopsy. The chi-square test was used to detect statistical significance. Of 57 lesions, 24 (42%) had invasion at excision. Symptomatic patients and patients with stiff lesions were more likely to have invasion than patients presenting through screening and with soft lesions (58% [14 of 24] versus 30% [10 of 33], p=0.03) and (51% [20 of 39] versus 22% [4 of 18], p=0.04). No other factors showed a relationship with invasion. Combining the two predictors of invasion improved risk stratification with symptomatic and stiff lesions having a risk of invasion of 67% (12 of 18) and soft lesions presenting at screening having only a 17% (2 of 12) risk of invasion (p=0.02). Stiffness on SWE and the referral source of the patient are predictors of occult invasion in women with an ultrasound-guided core biopsy diagnosis of DCIS. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  11. Brief reports: regional anesthesia needles can introduce ultrasound gel into tissues.

    PubMed

    Belavy, David

    2010-09-01

    Anesthesiologists may insert needles through ultrasound gel when performing ultrasound-guided regional anesthesia. In this study, it was determined whether needles carry gel into tissues. Ultrasound gel dyed blue was applied to pork rashers. Tuohy and short-bevel needles were passed through the gel and pork. The needles were then assessed for the presence of ultrasound gel. All needles, including those with stylets, carried gel and tissue within the lumen. Ultrasound gel may be injected around (and perhaps in) nerves during regional anesthesia procedures. Studies are needed to determine the implications of this practice.

  12. Comparison of lateral abdominal muscle thickness between weightlifters and matched controls.

    PubMed

    Sitilertpisan, Patraporn; Pirunsan, Ubon; Puangmali, Aatit; Ratanapinunchai, Jonjin; Kiatwattanacharoen, Suchart; Neamin, Hudsaleark; Laskin, James J

    2011-11-01

    To compare lateral abdominal muscle thickness between weightlifters and matched controls. A case control study design. University laboratory. 16 female Thai national weightlifters and 16 matched controls participated in this study. Ultrasound imaging with a 12-MHz linear array was used to measure the resting thickness of transversus abdominis (TrA), internal oblique (IO) and total thickness (Total) of lateral abdominal muscle (LAM) on the right side of abdominal wall. The absolute muscle thickness and the relative contribution of each muscle to the total thickness were determined. Weightlifters had significantly thicker absolute TrA and IO muscles than matched controls (p < 0.01). Further, the relative thickness of the IO was significantly greater in weightlifters than matched controls (p < 0.05). The findings of this study suggest that routine Olympic style weight training among female weightlifters appears to result in preferential hypertrophy or adaptation of the IO muscle. Copyright © 2011 Elsevier Ltd. All rights reserved.

  13. Image-Guided Surgery of Primary Breast Cancer Using Ultrasound Phased Arrays

    DTIC Science & Technology

    2004-07-01

    applications using high-intensity focused ultrasound ( HIFU ). We tems, Once the real-time imaging capability is available for have shown that this dual-mode...Arrays Emad S. Ebbini, PI Introduction High-intensity focus ultrasound ( HIFU ) is gaining wider acceptance in noninvasive or minimally invasive targeting of...Methods in Ultrasound Imaging, ISBI 2004, Arlington, VA, April 2004. III. Yao and Ebbini, "Real-Time Monitoring of the Transients of HIFU -Induced Lesions

  14. Physics and instrumentation of ultrasound.

    PubMed

    Lawrence, John P

    2007-08-01

    A thorough understanding of the physics of ultrasound waves and the instrumentation will provide the user with a better understanding of the capabilities and limitations of ultrasound equipment. The ultrasound machine combines two technologies: image production (M-mode and 2-dimensional imaging) with Doppler assessment (continuous and pulse wave as well as color-flow mapping). These distinct technologies have been combined to provide the examiner with the ability to make accurate and comprehensive diagnoses and guide therapeutic intervention.

  15. Ultrasound- and MRI-Guided Prostate Biopsy

    MedlinePlus

    ... which the MR images are fused with the real-time ultrasound images — an approach known as MRI/TRUS ... by a computer, which in turn creates a real-time picture on the monitor. One or more frames ...

  16. A Spine Loading Model of Women in the Military

    DTIC Science & Technology

    1996-10-01

    latissimuss dorsi, posterior abdominal internal obliques, rectus abdomini and the abdominal external obliques (5,19). MVC exertions consisting of...Women tend to possess greater hip breadth and narrower abdominal depth than men (9). The sacroiliac joint is positioned several centimeters anteriorly...internal obliques, external obliques, rectus abdomini, and psoas major. The sizes and area centriods are also quantified for the vertebral body and the

  17. The Applicability of the Army Physical Fitness Test in the Contemporary Operating Environment

    DTIC Science & Technology

    2008-06-13

    abdominis, external obliques, internal obliques, latissimus dorsi, lumbar paraspinals, and rectus femoris during performance of different abdominal ...by asserting the need to train soldiers in the most stressful, painful , realistic environment possible in order to prepare them for combat. Both of...In Medicine & Science in Sports & Exercise, researchers specifically identify usage of the rectus abdominis, external oblique, internal oblique

  18. Athletic pubalgia and the "sports hernia": MR imaging findings.

    PubMed

    Zoga, Adam C; Kavanagh, Eoin C; Omar, Imran M; Morrison, William B; Koulouris, George; Lopez, Hector; Chaabra, Avneesh; Domesek, John; Meyers, William C

    2008-06-01

    To retrospectively determine the sensitivity and specificity of magnetic resonance (MR) imaging findings in patients with clinical athletic pubalgia, with either surgical or physical examination findings as the reference standard. Institutional review board approval was granted for this HIPAA-compliant study, and informed consent was waived. MR imaging studies in 141 patients (134 male patients, seven female patients; mean age, 30.1 years; range, 17-71 years) who had been referred to a subspecialist because of groin pain were reviewed for findings including hernia, pubic bone marrow edema, secondary cleft sign, and rectus abdominis and adductor tendon injury. MR imaging findings were compared with surgical findings for 102 patients, physical examination findings for all 141 patients, and MR imaging findings in an asymptomatic control group of 25 men (mean age, 29.8 years; range, 18-39 years). Sensitivity and specificity of MR imaging for rectus abdominis and adductor tendon injury were determined by using a chi(2) analysis, and significance of the findings was analyzed with an unpaired Student t test. Disease patterns seen at MR imaging were compared with those reported in the surgical and sports medicine literature. One hundred thirty-eight (98%) of 141 patients had findings at MR imaging that could cause groin pain. Compared with surgery, MR imaging had a sensitivity and specificity, respectively, of 68% and 100% for rectus abdominis tendon injury and 86% and 89% for adductor tendon injury. Injury in each of these structures was significantly more common in the patient group than in the control group (P < .001). Only two patients had hernias at surgery. At MR imaging, injury or disease could be fit into distinct groups, including osteitis pubis, adductor compartment injury, rectus abdominis tendon injury, and injury or disease remote from the pubic symphysis. Patients with injury involving the rectus abdominis insertion were most likely to go on to surgical pelvic floor repair. MR imaging depicts patterns of findings in patients with athletic pubalgia, including rectus abdominis insertional injury, thigh adductor injury, and articular diseases at the pubic symphysis (osteitis pubis). (c) RSNA, 2008.

  19. Ultrasound Imaging and Guided Injection for the Lateral and Posterior Hip.

    PubMed

    Chang, Ke-Vin; Wu, Wei-Ting; Lew, Henry L; Özçakar, Levent

    2018-04-01

    Ultrasound has emerged as one of the most utilized tools to diagnose musculoskeletal disorders and to assist in interventions. Traditionally, sonographic examination of the hip joint has been challenging because most of the major structures are deeply situated, thus requiring the use of curvilinear transducer for better penetrance. The posterior lateral hip is a frequent area for musculoskeletal pain and nerve entrapments. Common disorders include greater trochanteric pain syndrome, gluteus medius tendinopathy, piriformis syndrome, pudendal neuralgia, and proximal hamstring tendinopathy. The present review article aims to delineate sonoanatomy of the posterior lateral hip and to exemplify several common ultrasound guided procedures at the greater trochanteric, gluteal, and ischial tuberosity regions.

  20. Thermal fixation of swine liver tissue after magnetic resonance-guided high-intensity focused ultrasound ablation.

    PubMed

    Courivaud, Frédéric; Kazaryan, Airazat M; Lund, Alice; Orszagh, Vivian C; Svindland, Aud; Marangos, Irina Pavlik; Halvorsen, Per Steinar; Jebsen, Peter; Fosse, Erik; Hol, Per Kristian; Edwin, Bjørn

    2014-07-01

    The aim of this study was to investigate experimental conditions for efficient and controlled in vivo liver tissue ablation by magnetic resonance (MR)-guided high-intensity focused ultrasound (HIFU) in a swine model, with the ultimate goal of improving clinical treatment outcome. Histological changes were examined both acutely (four animals) and 1 wk after treatment (five animals). Effects of acoustic power and multiple sonication cycles were investigated. There was good correlation between target size and observed ablation size by thermal dose calculation, post-procedural MR imaging and histopathology, when temperature at the focal point was kept below 90°C. Structural histopathology investigations revealed tissue thermal fixation in ablated regions. In the presence of cavitation, mechanical tissue destruction occurred, resulting in an ablation larger than the target. Complete extra-corporeal MR-guided HIFU ablation in the liver is feasible using high acoustic power. Nearby large vessels were preserved, which makes MR-guided HIFU promising for the ablation of liver tumors adjacent to large veins. Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

Top