Sample records for ultraviolet-filtering intraocular lens

  1. Intraocular and crystalline lens protection from ultraviolet damage.

    PubMed

    Sliney, David H

    2011-07-01

    Although the risks of excess solar ultraviolet (UV) exposure of the skin are well recognized, the need for eye protection is frequently overlooked, or when sunglasses are also recommended, specific guidance is wrong or is not explained. Guidance from the World Health Organization at its InterSun webpage advises people to wear "wrap-around" sunglasses under many conditions. The objective of this study was to examine the need for UV filtration in prescription lenses, contact lenses, and sunglasses. The geometry of UV exposure of both eyes, solar position, ground reflection, pupil size, and lid opening were studied. Because an accurate determination of cumulative ocular exposure is difficult, the cornea itself can serve as a biologic dosimeter, because photokeratitis is not experienced on a daily basis but does under certain ground-surface and sunlight conditions. From a knowledge of the UV-threshold dose required to produce photokeratitis, we have an upper level of routine ocular exposure to ambient UV. From ambient UV measurements and observed photokeratitis, the upper limits of UV exposure of the crystalline lens or an intraocular lens implant are estimated. The risk of excess UV exposure of the germinative cells of the lens is greatest from the side. Sunglasses can actually increase UV exposure of the germinative region of the crystalline lens and the corneal limbus by disabling the eyes' natural protective mechanisms of lid closure and pupil constriction! The level of UV-A risk is difficult to define. Proper UV-absorbing contact lenses offer the best mode for filtering needless exposure of UV radiation of the lens and limbus.

  2. Ultraviolet-B phototoxicity and hypothetical photomelanomagenesis: intraocular and crystalline lens photoprotection.

    PubMed

    Mainster, Martin A; Turner, Patricia L

    2010-04-01

    Ultraviolet-B (UV-B) radiation can cause phototoxic macular injuries in young people who have been sunbathing but not sungazing and in welders. Welders have a reportedly increased risk of uveal melanoma. We analyze phakic and pseudophakic risks for solar and welding arc UV-B exposure. Optical radiation measurement, analysis, and perspective. Spectral transmittances were measured for UV-transmitting, UV-blocking, and blue-blocking intraocular lenses (IOLs). The photoprotective performances of crystalline and intraocular lenses were analyzed using relevant epidemiologic and laboratory data and action spectra for acute retinal phototoxicity and melanoma photocarcinogenesis. Crystalline lens UV-B retinal protection is deficient in children and young adults, increasing their potential susceptibility to acute retinal phototoxicity and hypothetical photomelanomagenesis. UV-B radiation has sufficient energy/photon to induce primary melanomagenic DNA lesions, unlike blue light or UV-A radiation. UV-blocking and blue-blocking IOLs have negligible UV-B transmittance. UV-transmitting IOL transmittance of UV-B radiation is equivalent to that of a 15-year-old crystalline lens. If optical radiation exposure is responsible for welders' increased risk of uveal melanoma, then UV-B radiation is the most probable causative agent and spectacle wear is a potential confounding factor in epidemiologic studies of ocular melanoma. Welders under 30 years of age are at greater risk for welding maculopathy than older welders. Children, adults under 30 years of age, and pseudophakic individuals with UV-transmitting IOLs should wear sunglasses in bright environments because of the UV-B window in their crystalline lenses or IOLs. Copyright 2010 Elsevier Inc. All rights reserved.

  3. 21 CFR 886.3600 - Intraocular lens.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Intraocular lens. 886.3600 Section 886.3600 Food... DEVICES OPHTHALMIC DEVICES Prosthetic Devices § 886.3600 Intraocular lens. (a) Identification. An intraocular lens is a device made of materials such as glass or plastic intended to be implanted to replace...

  4. [New trends of customizing intraocular lens choice].

    PubMed

    He, Shou-zhi

    2006-05-01

    Definition and basic principle of customizing intraocular lens choice are described. The importance of the choicing intraocular lens for individual patient is illustrated. The review emphasizes that it is surgeon's responsibility to choice the appropriate intraocular lens for the best postoperative outcome and patient's satisfaction.

  5. 21 CFR 886.4300 - Intraocular lens guide.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Intraocular lens guide. 886.4300 Section 886.4300...) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4300 Intraocular lens guide. (a) Identification. An intraocular lens guide is a device intended to be inserted into the eye during surgery to direct...

  6. Optimized constants for an ultraviolet light-adjustable intraocular lens.

    PubMed

    Conrad-Hengerer, Ina; Dick, H Burkhard; Hütz, Werner W; Haigis, Wolfgang; Hengerer, Fritz H

    2011-12-01

    To determine the accuracy of intraocular lens (IOL) power calculations and to suggest adjusted constants for implantation of ultraviolet light-adjustable IOLs. Center for Vision Science, Ruhr University Eye Clinic, Bochum, Germany. Cohort study. Eyes with a visually significant cataract that had phacoemulsification with implantation of a light-adjustable IOL were evaluated. IOLMaster measurements were performed before phacoemulsification and IOL implantation and 4 weeks after surgery before the first adjustment of the IOL. The difference in the expected refraction and estimation error was studied. The study evaluated 125 eyes. Using the surgical constants provided by the manufacturer of the light-adjustable IOL, the SRK/T formula gave a more hyperopic refraction than the Hoffer Q and Holladay 1 formulas. The mean error of prediction was 0.93 diopter (D) ± 0.69 (SD), 0.91 ± 0.63 D, and 0.86 ± 0.65 D, respectively. The corresponding mean absolute error of prediction was 0.98 ± 0.61 D, 0.93 ± 0.61 D, and 0.90 ± 0.59 D, respectively. With optimized constants for the formulas, the mean error of prediction was 0.00 ± 0.63 D for Hoffer Q, 0.00 ± 0.64 D for Holladay 1, and 0.00 ± 0.66 D for SRK/T. The expected refraction after phacoemulsification and implantation of a light-adjustable IOL toward the hyperopic side of the desired refraction could be considered when using the optimized constants for all formulas. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  7. [The effect of yellow filter intraocular lens on the macula after cataract phacoemulsification in patients with age macular degeneration].

    PubMed

    Shpak, A A; Maliugin, B É; Fadeeva, T V

    2012-01-01

    Macula changes diagnosed with optical coherence tomography (OCT) within a year after cataract phacoemulsification (PE) with intraocular lens implantation with and without yellow filter are presented. 32 patients (36 eyes) with early stages of age macular degeneration (AMD) were included into the experimental group and 35 patients (36 eyes) served as controls. IOLs with yellow filter were implanted in 21 eyes, and in 15 cases IOLs without filter were used in each group. According to OCT data thickening of fovea and increasing of macula volume developed within 6 months after cataract PE. Implantation of yellow filter IOLs reduced the intensity of these changes after surgery in patients with AMD. The progression of early AMD into advanced stages within a year after PE was not observed.

  8. Piggyback intraocular lens implantation to correct pseudophakic refractive error after segmental multifocal intraocular lens implantation.

    PubMed

    Venter, Jan A; Oberholster, Andre; Schallhorn, Steven C; Pelouskova, Martina

    2014-04-01

    To evaluate refractive and visual outcomes of secondary piggyback intraocular lens implantation in patients diagnosed as having residual ametropia following segmental multifocal lens implantation. Data of 80 pseudophakic eyes with ametropia that underwent Sulcoflex aspheric 653L intraocular lens implantation (Rayner Intraocular Lenses Ltd., East Sussex, United Kingdom) to correct residual refractive error were analyzed. All eyes previously had in-the-bag zonal refractive multifocal intraocular lens implantation (Lentis Mplus MF30, models LS-312 and LS-313; Oculentis GmbH, Berlin, Germany) and required residual refractive error correction. Outcome measurements included uncorrected distance visual acuity, corrected distance visual acuity, uncorrected near visual acuity, distance-corrected near visual acuity, manifest refraction, and complications. One-year data are presented in this study. The mean spherical equivalent ranged from -1.75 to +3.25 diopters (D) preoperatively (mean: +0.58 ± 1.15 D) and reduced to -1.25 to +0.50 D (mean: -0.14 ± 0.28 D; P < .01). Postoperatively, 93.8% of eyes were within ±0.50 D and 98.8% were within ±1.00 D of emmetropia. The mean uncorrected distance visual acuity improved significantly from 0.28 ± 0.16 to 0.01 ± 0.10 logMAR and 78.8% of eyes achieved 6/6 (Snellen 20/20) or better postoperatively. The mean uncorrected near visual acuity changed from 0.43 ± 0.28 to 0.19 ± 0.15 logMAR. There was no significant change in corrected distance visual acuity or distance-corrected near visual acuity. No serious intraoperative or postoperative complications requiring secondary intraocular lens removal occurred. Sulcoflex lenses proved to be a predictable and safe option for correcting residual refractive error in patients diagnosed as having pseudophakia. Copyright 2014, SLACK Incorporated.

  9. 21 CFR 886.4300 - Intraocular lens guide.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4300 Intraocular lens guide. (a) Identification. An intraocular lens guide is a device intended to be inserted into the eye during surgery to direct... lenses, the device is exempt from the premarket notification procedures in subpart E of part 807 of this...

  10. Relationship of the actual thick intraocular lens optic to the thin lens equivalent.

    PubMed

    Holladay, J T; Maverick, K J

    1998-09-01

    To theoretically derive and empirically validate the relationship between the actual thick intraocular lens and the thin lens equivalent. Included in the study were 12 consecutive adult patients ranging in age from 54 to 84 years (mean +/- SD, 73.5 +/- 9.4 years) with best-corrected visual acuity better than 20/40 in each eye. Each patient had bilateral intraocular lens implants of the same style, placed in the same location (bag or sulcus) by the same surgeon. Preoperatively, axial length, keratometry, refraction, and vertex distance were measured. Postoperatively, keratometry, refraction, vertex distance, and the distance from the vertex of the cornea to the anterior vertex of the intraocular lens (AV(PC1)) were measured. Alternatively, the distance (AV(PC1)) was then back-calculated from the vergence formula used for intraocular lens power calculations. The average (+/-SD) of the absolute difference in the two methods was 0.23 +/- 0.18 mm, which would translate to approximately 0.46 diopters. There was no statistical difference between the measured and calculated values; the Pearson product-moment correlation coefficient from linear regression was 0.85 (r2 = .72, F = 56). The average intereye difference was -0.030 mm (SD, 0.141 mm; SEM, 0.043 mm) using the measurement method and +0.124 mm (SD, 0.412 mm; SEM, 0.124 mm) using the calculation method. The relationship between the actual thick intraocular lens and the thin lens equivalent has been determined theoretically and demonstrated empirically. This validation provides the manufacturer and surgeon additional confidence and utility for lens constants used in intraocular lens power calculations.

  11. Intraocular lens fabrication

    DOEpatents

    Salazar, Mike A.; Foreman, Larry R.

    1997-01-01

    This invention describes a method for fabricating an intraocular lens made rom clear Teflon.TM., Mylar.TM., or other thermoplastic material having a thickness of about 0.025 millimeters. These plastic materials are thermoformable and biocompatable with the human eye. The two shaped lenses are bonded together with a variety of procedures which may include thermosetting and solvent based adhesives, laser and impulse welding, and ultrasonic bonding. The fill tube, which is used to inject a refractive filling material is formed with the lens so as not to damage the lens shape. A hypodermic tube may be included inside the fill tube.

  12. Intraocular lens fabrication

    DOEpatents

    Salazar, M.A.; Foreman, L.R.

    1997-07-08

    This invention describes a method for fabricating an intraocular lens made from clear Teflon{trademark}, Mylar{trademark}, or other thermoplastic material having a thickness of about 0.025 millimeters. These plastic materials are thermoformable and biocompatable with the human eye. The two shaped lenses are bonded together with a variety of procedures which may include thermosetting and solvent based adhesives, laser and impulse welding, and ultrasonic bonding. The fill tube, which is used to inject a refractive filling material is formed with the lens so as not to damage the lens shape. A hypodermic tube may be included inside the fill tube. 13 figs.

  13. Severe pigment dispersion after iris-claw phakic intraocular lens implantation.

    PubMed

    Galvis, Virgilio; Carreño, Néstor I; Tello, Alejandro; Laiton, Andrea N

    2017-12-01

    A 23-year-old female patient presented 3 months after the implantation of an Artisan® phakic intraocular lens with a severe depigmentation of the iris and peripheral anterior synechiae. Explantation of the intraocular lens and goniosynechialysis were performed. Eleven months after the explantation appearance of the iris significantly improved. There was no loss of lines of corrected distance visual acuity. Severe pigment dispersion after the implantation of an Artisan® phakic intraocular lens may happen and may require explantation of the lens. Iris depigmentation may improve with time.

  14. Population-based Incidence of Intraocular Lens Exchange in Olmsted County, Minnesota.

    PubMed

    Bothun, Erick D; Cavalcante, Lilian C B; Hodge, David O; Patel, Sanjay V

    2018-03-01

    To determine the population-based incidence of pseudophakic intraocular lens exchange in Olmsted County, Minnesota. Retrospective review of a population-based cohort. Patients undergoing pseudophakic intraocular lens exchange in Olmsted County, Minnesota, between January 1, 1986 and December 31, 2016 were identified from the Rochester Epidemiology Project medical record linkage system. Indications and outcomes were determined, and the incidence rate was calculated as cases per 1 000 000 person-years. Poisson regression analysis was used to assess changes in incidence over time, and the cumulative probability of needing a lens exchange was estimated by Kaplan-Meier analysis. Eighty cases of intraocular lens exchange were identified, yielding an overall age- and sex-adjusted incidence rate of 28.4 per million (confidence interval [CI], 22.1-34.7), which increased over the study period (P = .04). The 30-year cumulative probability of intraocular lens exchange among patients undergoing cataract surgery was 1.5% (CI, 0.6%-2.4%), increasing at a relatively constant rate. Dislocated lenses accounted for 72.5% of lens exchanges. Unplanned refractive outcome of primary cataract surgery and uveitis-glaucoma-hyphema syndrome from squared-edged haptics emerged as newer indications for intraocular lens exchange. The population-based incidence of pseudophakic intraocular lens exchange has increased over the last 30 years, and can be explained by the increase in incidence rate of cataract surgery over the same period. Surgeons should be aware of emerging indications of intraocular lens exchange, which reflect changes in lens design and increasing expectations of refractive outcomes. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. 21 CFR 886.3600 - Intraocular lens.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Intraocular lens. 886.3600 Section 886.3600 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL... the natural lens of an eye. (b) Classification. Class III. (c) Date PMA or notice of completion of a...

  16. Effects of a blue light-filtering intraocular lens on driving safety in glare conditions.

    PubMed

    Gray, Rob; Hill, Warren; Neuman, Brooke; Houtman, Diane; Potvin, Richard

    2012-05-01

    To evaluate whether the previously established benefit of blue light-filtering intraocular lenses (IOLs) when driving in glare conditions is maintained in patients previously implanted with a blue light-filtering toric IOL. Department of Applied Psychology, Arizona State University, Mesa, Arizona, USA. Comparative case series. The study comprised patients with a blue light-filtering toric IOL (test IOL) or an ultraviolet (UV)-only filtering nontoric IOL (control IOL). All patients had good visual acuity and a valid driver's license. While wearing best spherocylindrical correction, patients performed left-turn maneuvers in front of oncoming traffic in a driving simulator. The safety margin was defined as the time to collision less the time taken to turn at an intersection with oncoming traffic. Measures were repeated with a glare source simulating low-angle sun conditions (daytime driving). Of the 33 evaluable patients, 18 had a test IOL and 15 had a control IOL. In the presence of glare, patients with test IOLs had significantly greater safety margins (mean 2.676 seconds ± 0.438 [SD]) than patients with control IOLs (mean 2.179 ± 0.343 seconds) and significantly lower glare susceptibility (P<.05). In no-glare and glare conditions, patients with test IOLs had significantly lower glare susceptibility than patients with control IOLs. The blue light-filtering toric IOL produced a significantly greater reduction in glare disability than the UV-only filtering nontoric IOL and increased the ability of drivers to safely execute left turns in low-sun conditions. Dr. Houtman is an employee of Alcon Laboratories, Inc. No other author has a financial or proprietary interest in any material or method mentioned. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  17. The Fyodorov Sputnik intraocular lens.

    PubMed

    Kwitko, M L

    1979-04-01

    The author has implanted 197 Fyodorov intraocular lenses. With careful selection of patients, good surgical judgment, and meticulous surgery, a degree of success can be obtained with this lens, which will equal that of conventional cataract surgery. The surgical technique of implantation will be described.

  18. Changes in blood pressure and sleep duration in patients with blue light-blocking/yellow-tinted intraocular lens (CHUKYO study).

    PubMed

    Ichikawa, Kazuo

    2014-07-01

    Blood pressure and sleep duration may be influenced by retinal light exposure. Cataracts may exert such an influence by decreasing the transparency of the crystalline lens. A large-scale clinical study was conducted to examine changes in blood pressure and sleep duration after intraocular lens (IOL) implantation during cataract surgery and to investigate how different types of IOL influence the degree of these effects. Using a questionnaire, we collected information, including blood pressure measurement and sleep duration, from 1367 patients (1367 eyes) before IOL implantation, 1 week after IOL implantation and 1 month after IOL implantation. Systolic and diastolic blood pressures were significantly decreased in the total patient group after implantation. The decrease in systolic blood pressure 1 month after implantation was significantly more in patients who received a yellow-tinted IOL than it was in those who received an ultraviolet (UV) light-filtering IOL. The post-implantation sleep duration, including naps, became shorter in patients who had slept too much and became longer in those who had slept too little before IOL implantation. Our observations suggest that a yellow-tinted IOL is better for patients with high blood pressure than a UV light-filtering IOL. Furthermore, the yellow-tinted IOL is as good as the UV light-filtering IOL for improving sleep duration. A pale yellow-tinted IOL is likely to be superior to a moderate yellow-tinted IOL in terms of allowing patients to discriminate different colors. Thus, the pale yellow-tinted IOL appears to be better for patients than the UV light-filtering IOL and the moderate yellow-tinted IOL.

  19. Pigment dispersion syndrome associated with intraocular lens implantation: a new surgical technique.

    PubMed

    Canut Jordana, M Isabel; Pérez Formigó, Daniel; Abreu González, Rodrigo; Nadal Reus, Jeroni

    2010-11-11

    We report the case of a myopic patient who, after intraocular lens transplant in the posterior chamber, suffered elevated intraocular pressure due to pigment dispersion, with recurrent episodes of blurred vision. The patient was treated with a new surgical technique that can avoid potential iridolenticular contact. Complete ophthalmologic examination and optical coherence tomography (OCT) of the anterior segment were performed. Contact between the pigmentary epithelium and the iris with an intraocular lens was revealed by utrasound biomicroscopy and OCT. In this case, Nd:YAG laser iridotomy and laser iridoplasty were not effective for iridolenticular separation and control of the pigment dispersion. We propose a new technique: stitches on the surface of the iris to obtain good iridolenticular separation and good intraocular pressure control. Stitches on the iris surface should be considered as optional therapy in pigmentary glaucoma secondary to intraocular lens implantation. This surgical technique can avoid potential iridolenticular contacts more definitively.

  20. Magnetically adjustable intraocular lens.

    PubMed

    Matthews, Michael Wayne; Eggleston, Harry Conrad; Pekarek, Steven D; Hilmas, Greg Eugene

    2003-11-01

    To provide a noninvasive, magnetic adjustment mechanism to the repeatedly and reversibly adjustable, variable-focus intraocular lens (IOL). University of Missouri-Rolla, Rolla, and Eggleston Adjustable Lens, St. Louis, Missouri, USA. Mechanically adjustable IOLs have been fabricated and tested. Samarium and cobalt rare-earth magnets have been incorporated into the poly(methyl methacrylate) (PMMA) optic of these adjustable lenses. The stability of samarium and cobalt in the PMMA matrix was examined with leaching studies. Operational force testing of the magnetic optics with emphasis on the rotational forces of adjustment was done. Prototype optics incorporating rare-earth magnetic inserts were consistently produced. After 32 days in solution, samarium and cobalt concentration reached a maximum of 5 ppm. Operational force measurements indicate that successful adjustments of this lens can be made using external magnetic fields with rotational torques in excess of 0.6 ounce inch produced. Actual lenses were remotely adjusted using magnetic fields. The magnetically adjustable version of this IOL is a viable and promising means of handling the common issues of postoperative refractive errors without the requirement of additional surgery. The repeatedly adjustable mechanism of this lens also holds promise for the developing eyes of pediatric patients and the changing needs of all patients.

  1. Introduction to the development of intraocular lens

    NASA Astrophysics Data System (ADS)

    Li, Yifan; Peng, Runling; Hu, Shuilan; Wei, Maowei; Chen, Jiabi

    2013-08-01

    In order to cure the cataract disease or injuries in eyes, intraocular lens(IOL) has been studied all the time to replace the crystalline lens in human eyes. Researches on IOL are started early from 19th century, and it develops greatly in the hundreds years after. This article introduces several main kinds of IOLs that appear in the development history of IOL, and raises the double-liquid zoom IOL based on electrowetting, which will be the trend of IOL study.

  2. Delayed presentation of retained acrylic intraocular lens (IOL) fragment after uncomplicated cataract surgery.

    PubMed

    Capitena, Cara E; Gamett, Kevin; Pantcheva, Mina B

    2016-10-01

    To report a case of delayed presentation of a severed acrylic single-piece intraocular lens (IOL) haptic fragment causing corneal edema after uneventful phacoemulsification surgery. An 85-year-old male presented with inferior corneal decompensation six months after a reportedly uneventful phacoemulsification in his left eye. A distal haptic fragment of an acrylic single-piece posterior chamber intraocular lens was found in the inferior anterior chamber angle. Intraoperative examination revealed that the dislocated fragment originated from the temporal haptic, the remainder of which was adherent to the anterior surface of the capsular bag. The clipped edge of the haptic fragment showed a clean, flat surface, suggesting it was severed by a sharp object. The findings were considered consistent with cutting of the fragment during implantation presumably from improper lens loading, improper implantation technique, or defective implantation devices. This is the first case report of a foldable acrylic intraocular lens severed during routine uncomplicated cataract surgery that was not noted at the time of the surgery or in the immediate postoperative period. Delayed presentation of severed IOL fragments should be considered in cases of late onset corneal edema post-operatively, when other causes have been ruled out. Careful implantation technique and thorough examination of the intraocular lens after implantation to assess for lens damage intraoperatively is essential to avoid such rare complications.

  3. Toric Intraocular Lens Outcomes in Patients With Glaucoma.

    PubMed

    Brown, Reay H; Zhong, Le; Bozeman, Caroline W; Lynch, Mary G

    2015-06-01

    To report the outcomes of toric intraocular lens implantation in patients with glaucoma and corneal astigmatism. One hundred twenty-six eyes of 87 patients with glaucoma and corneal astigmatism that underwent cataract surgery with an AcrySof toric intraocular lens (Alcon Laboratories, Inc., Fort Worth, TX) implant were selected for this single-center, retrospective case series. Corrected distance visual acuity, intraocular pressure, and refractive astigmatism were measured in each eye preoperatively and postoperatively. Uncorrected distance visual acuity and toric alignment were measured postoperatively. The uncorrected distance visual acuity was 0.04 ± 0.08 logMAR (20/22 Snellen) for all eyes. Ninety-eight percent of all eyes achieved an uncorrected distance visual acuity of 20/40 or better, with 76% achieving 20/25 or better and 47% achieving 20/20. The corrected distance visual acuity for all eyes was 0.01 ± 0.03 logMAR (20/20.5 Snellen) postoperatively. The refractive cylinder improved from 1.47 ± 1.10 diopters preoperatively to 0.31 ± 0.37 diopters postoperatively. The residual refractive cylinder was 1.00 diopter or less in 97% of eyes, 0.75 diopters or less in 90% of eyes, and 0.50 diopters or less in 83% of eyes. Mean misalignment was 4.4° ± 5.1°. Intraocular pressure decreased by a mean of 2.3 ± 3.3 mm Hg following the surgery. Toric intraocular lenses can reliably reduce astigmatism and improve uncorrected vision in eyes with cataract and glaucoma. Copyright 2015, SLACK Incorporated.

  4. Comparison of visual outcomes after bilateral implantation of a diffractive trifocal intraocular lens and blended implantation of an extended depth of focus intraocular lens with a diffractive bifocal intraocular lens

    PubMed Central

    de Medeiros, André Lins; de Araújo Rolim, André Gustavo; Motta, Antonio Francisco Pimenta; Ventura, Bruna Vieira; Vilar, César; Chaves, Mário Augusto Pereira Dias; Carricondo, Pedro Carlos; Hida, Wilson Takashi

    2017-01-01

    Purpose The purpose of this study was to compare the visual outcomes and subjective visual quality between bilateral implantation of a diffractive trifocal intraocular lens, Alcon Acrysof IQ® PanOptix® TNFT00 (group A), and blended implantation of an extended depth of focus lens, J&J Tecnis Symfony® ZXR00 with a diffractive bifocal intraocular lens, J&J Vision Tecnis® ZMB00 (group B). Methods This prospective, nonrandomized, consecutive, comparative study included the assessment of 40 eyes in 20 patients implanted with multifocal intraocular lens. Exclusion criteria were existence of any corneal, retina, or optic nerve disease, previous eye surgery, illiteracy, previous refractive surgery, high axial myopia, expected postoperative corneal astigmatism of >1.00 cylindrical diopter (D), and intraoperative or postoperative complications. Binocular visual acuity was tested in all cases. Ophthalmological evaluation included the measurement of uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected near visual acuity (UNVA), and uncorrected intermediate visual acuity (UIVA), with the analysis of contrast sensitivity (CS), and visual defocus curve. Results Postoperative UDVA was 0.01 and −0.096 logMAR (p<0.01) in groups A and B, respectively; postoperative CDVA was −0.07 and −0.16 logMAR (p<0.01) in groups A and B, respectively; UIVA was 0.14 and 0.20 logMAR (p<0.01) in groups A and B, respectively; UNVA was −0.03 and 0.11 logMAR (p<0.01) in groups A and B, respectively. Under photopic conditions group B had better CS at low frequencies with and without glare. Conclusion Both groups promoted good quality of vision for long, intermediate, and short distances. Group B exhibited a better performance for very short distances and for intermediate and long distances ≥−1.50 D of vergence. Group A exhibited a better performance for UIVA at 60 cm and for UNVA at 40 cm. PMID:29138533

  5. [Correction of aphakia with the implantation of the retropupillary iris clip intraocular artificial lens].

    PubMed

    Szabó, Antal; Papp, András; Borbándy, Ágnes; D Géhl, Zsuzsanna; Nagy, Zoltán Zsolt; Resch, Miklós

    2017-01-01

    The correction of aphakia might be a challenge for the surgeon. The aim of this study is to describe the authors' experience with the implantation of the retropupillary iris clip intraocular lens. Patients between January 2014 and December 2015 were included in the retrospective study. Retropupillary implantation of iris clip intraocular lens VRSA 54 (AMO Advanced Medical Optics, USA) was performed in all cases. The minimum follow up period was three months. The stability of the intraocular lens and the intraoperative and postoperative complications and the visual acuity were evaluated. During this time period 11 cases (1 female, 10 males) were included in the study. The mean age at the time of the implantation was 57.7 years (between 25-74 years). In 4 cases the iris clip lens was implanted during the first intervention, in 7 cases during the secondary procedure. In all cases the lens was fixated onto the iris posteriorly. The best corrected visual acuity before the iris clip implantation was 0.43 (0.1-1.0) and postoperatively at the time of the follow up 0.49 (0.04-1.0). With the use of the retropupillary implanted iris clip intraocular lens all of the patients could have been rehabilitated without major complications. Orv. Hetil., 2017, 158(1), 20-24.

  6. Deformable Surface Accommodating Intraocular Lens: Second Generation Prototype Design Methodology and Testing.

    PubMed

    McCafferty, Sean J; Schwiegerling, Jim T

    2015-04-01

    Present an analysis methodology for developing and evaluating accommodating intraocular lenses incorporating a deformable interface. The next generation design of extruded gel interface intraocular lens is presented. A prototype based upon similar previously in vivo proven design was tested with measurements of actuation force, lens power, interface contour, optical transfer function, and visual Strehl ratio. Prototype verified mathematical models were used to optimize optical and mechanical design parameters to maximize the image quality and minimize the required force to accommodate. The prototype lens produced adequate image quality with the available physiologic accommodating force. The iterative mathematical modeling based upon the prototype yielded maximized optical and mechanical performance through maximum allowable gel thickness to extrusion diameter ratio, maximum feasible refractive index change at the interface, and minimum gel material properties in Poisson's ratio and Young's modulus. The design prototype performed well. It operated within the physiologic constraints of the human eye including the force available for full accommodative amplitude using the eye's natural focusing feedback, while maintaining image quality in the space available. The parameters that optimized optical and mechanical performance were delineated as those, which minimize both asphericity and actuation pressure. The design parameters outlined herein can be used as a template to maximize the performance of a deformable interface intraocular lens. The article combines a multidisciplinary basic science approach from biomechanics, optical science, and ophthalmology to optimize an intraocular lens design suitable for preliminary animal trials.

  7. Biocompatibility of poloxamer hydrogel as an injectable intraocular lens: a pilot study.

    PubMed

    Kwon, Ji Won; Han, Young Keun; Lee, Woo Jin; Cho, Chong Su; Paik, Seung Joon; Cho, Dong Il; Lee, Jin Hak; Wee, Won Ryang

    2005-03-01

    To induce irreversible gelation of poloxamer, a thermosensitive polymer hydrogel, by using a photoinitiator and ultraviolet (UV) irradiation and to verify the biocompatibility and use of poloxamer as an injectable intraocular lens (IOL) material. Department of Ophthalmology, Seoul National University College of Medicine, Seoul Artificial Eye Center, Clinical Research Institute, Seoul National University Hospital, Seoul, Korea. In 10 rabbits, endocapsular phacoemulsification was performed and a poloxamer-photoinitiator mixture was injected into the capsular bag through a small capsulorhexis site. In 1 eye, the capsulorhexis site was closed with a small plug and the entire eye was irradiated with UV light for 5 minutes. Postoperatively, poloxamer transparency and effect on the conjunctiva, cornea, iris, vitreous, and retina were observed. A mixture comprising 25% poloxamer and 0.01% photoinitiator produced a poloxamer that remained transparent in the lens capsule for up to 6 months. No inflammatory response or toxicity was observed in the conjunctiva, cornea, iris, vitreous, or retina. Poloxamer is a potentially suitable material for an injectable IOL. Further study is needed.

  8. Bilateral phacoemulsification and intraocular lens implantation in a great horned owl.

    PubMed

    Carter, Renee T; Murphy, Christopher J; Stuhr, Charles M; Diehl, Kathryn A

    2007-02-15

    A great horned owl of estimated age < 1 year that was captured by wildlife rehabilitators was evaluated because of suspected cataracts. Nuclear and incomplete cortical cataracts were evident in both eyes. Ocular ultrasonography revealed no evidence of retinal detachment, and electroretinography revealed normal retinal function. For visual rehabilitation, cataract surgery was planned and intraocular lens design was determined on the basis of values obtained from the schematic eye, which is a mathematical model representing a normal eye for a species. Cataract surgery and intraocular lens placement were performed in both eyes. After surgery, refraction was within -0.75 diopters in the right eye and -0.25 diopters in the left eye. Visual rehabilitation was evident on the basis of improved tracking and feeding behavior, and the owl was eventually released into the wild. In raptors with substantial visual compromise, euthanasia or placement in a teaching facility is a typical outcome because release of such a bird is unacceptable. Successful intraocular lens implantation for visual rehabilitation and successful release into the wild are achievable.

  9. Psychophysical Measurements of Luminance Contrast Sensitivity and Color Discrimination with Transparent and Blue-Light Filter Intraocular Lenses.

    PubMed

    da Costa, Marcelo Fernandes; Júnior, Augusto Paranhos; Lottenberg, Claudio Luiz; Castro, Leonardo Cunha; Ventura, Dora Fix

    2017-12-01

    The purpose of this study was to measure luminance contrast sensitivity and color vision thresholdfs in normal subjects using a blue light filter lens and transparent intraocular lens material. Monocular luminance grating contrast sensitivity was measured with Psycho for Windows (version 2.36; Cambridge Research Systems) at 3.0, 6.0, 12.0, 20.0, and 30.0 cycles per degree of visual angle (cpd) in 15 normal subjects (eight female), with a mean age of 21.6 years (SD = 3.8 years). Chromatic discrimination was assessed with the Cambridge colour test (CCT) along the protan, deutan, and tritan color confusion axes. Both tests were performed in a darkened room under two situations: with a transparent lens and with blue light filter lens. Subjective impressions were taken by subjects regarding their visual experience under both conditions. No difference was found between the luminance contrast sensitivity measured with transparent and blue light filter. However, 13/15 (87%) of the subjects reported more comfortable vision with the blue filter. In the color vision test, tritan thresholds were significantly higher for the blue filter compared with the transparent filter (p = 0.003). For protan and deutan thresholds no differences were found. Blue-yellow color vision is impaired with the blue light filter, and no impairment occurs with the transparent filter. No significant differences in thresholds were found in the luminance contrast sensitivity comparing the blue light and transparent filters. The impact of short wavelength light filtering on intrinsically photosensitive retinal ganglion cells is also discussed.

  10. INTRAOCULAR LENS SCAFFOLD TO PREVENT INTRAOCULAR FOREIGN BODY SLIPPAGE.

    PubMed

    Agarwal, Amar; Ashok Kumar, Dhivya; Agarwal, Athiya

    2017-01-01

    To report the application of intraocular lens (IOL) scaffold technique in intraocular foreign body (IOFB) removal. Patient with IOFB in posterior segment is included. The IOFB is retrieved from the posterior segment (pars plana vitrectomy and exteriorization of the IOFB from the retinal surface using an intravitreal forceps via the posterior capsulotomy) and placed on the iris. A three-piece posterior chamber IOL is placed in the sulcus via the clear corneal incision. IOFB is then removed from the anterior chamber over the IOL by forceps. Metallic IOFB of 4 mm × 3 mm has been retrieved by IOL scaffold technique after rescuing it from the posterior segment. There has been no drop or slip of IOFB in the vitreous during removal. Posterior chamber IOL served as scaffold during IOFB removal from anterior chamber. The IOL scaffold maneuver has shown to prevent slippage by acting as a barrier between the IOFB and the vitreous.

  11. Iris-Claw Intraocular Lens and Scleral-Fixated Posterior Chamber Intraocular Lens Implantations in Correcting Aphakia: A Meta-Analysis.

    PubMed

    Jing, Wu; Guanlu, Liang; Qianyin, Zheng; Shuyi, Li; Fengying, He; Jian, Liu; Wen, Xu

    2017-07-01

    A meta-analysis to compare iris-claw intraocular lens (IC-IOL) and scleral-fixated posterior chamber intraocular lens (SF-PCIOL) implantations in correcting aphakia without sufficient capsular support. Eligible studies were collected through PubMed, Web of Science, Embase, and the Cochrane library. The pooled relative risks (RR), pooled standardized mean difference (SMD), and their 95% confidence interval of the eligible studies were then calculated. Seven studies met our inclusion criteria, involving 232 and 158 eyes in IC-IOL and SF-PCIOL groups, respectively. The pooled SMD of the mean postoperative corrected distance visual acuity (CDVA) (logMAR) was -0.25. The pooled RR of the eyes achieving 20/40 or better postoperatively was 1.16. The pooled SMD of the surgical time was -2.97. The pooled RR of the surgical complications was 0.86. The pooled RR of IOL dislocation, retinal detachment (RD), and cystoid macular edema (CME) between the two groups were 0.22, 0.63, and 0.64. Implantation of IC-IOL has a more simple procedure and shorter learning curve than SF-PCIOL implantation in correcting aphakia without sufficient capsular support.

  12. [Hyperopic Laser-in-situ-Keratomileusis after trifocal intraocular lens implantation : Aberration-free femto-Laser-in-situ-Keratomileusis treatment after implantation of a diffractive, multifocal, toric intraocular lens-case analysis].

    PubMed

    Hemkeppler, E; Böhm, M; Kohnen, T

    2018-05-29

    A 52-year-old highly myopic female patient was implanted with a multifocal, diffractive, toric intraocular lens because of the wish to be independent of eyeglasses. Despite high-quality, extensive preoperative examinations, a hyperopic refractive error remained postoperatively, which led to the patient's dissatisfaction. This error was treated with Laser-in-situ-Keratomileusis (LASIK). After corneal LASIK treatment and implantation of a diffractive toric multifocal intraocular lens the patient showed a good postoperative visual result without optical phenomena.

  13. Comparison of hydrophobic and hydrophilic intraocular lens in preventing posterior capsule opacification after cataract surgery

    PubMed Central

    Zhao, Yang; Yang, Ke; Li, Jiaxin; Huang, Yang; Zhu, Siquan

    2017-01-01

    Abstract Background: Posterior capsular opacification (PCO) is a common long-term complication of cataract surgery. Intraocular lens design and material have been implicated in influencing the development of PCO. This study evaluated the association of hydrophobic and hydrophilic intraocular lenses on preventing PCO. Methods: Medline, Cochrane, EMBASE, and Google Scholar databases were searched until August 3, 2016, using the following search terms: cataract, posterior capsule opacification, and intraocular lens. Eligible studies included randomized controlled trials (RCTs), retrospective, and cohort studies. Results: Eleven studies were included in the study with a total of 889 eyes/patients. The overall analysis revealed that hydrophobic intraocular lenses were associated with lower Nd:YAG laser capsulotomy rates than hydrophilic lenses [odds ratio (OR) = 0.38, 95% confidence interval (95% CI) = 0.16–0.91, P = .029]. Hydrophobic intraocular lenses were also associated with lower subjective PCO score (diff. in means: −1.32, 95% CI = −2.39 to −0.25, P = .015) and estimated PCO score (diff. in means: −2.23; 95% CI, −3.80 to −0.68, P = .005) as compared with hydrophilic lenses. Objective PCO score was similar between lens types. (diff. in means: −0.075; 95% CI, −0.18 to 0.035; P = .182). Pooled analysis found that visual acuity was similar between hydrophobic and hydrophilic intraocular lenses (diff. in means: −0.016; 95% CI, −0.041 to 0.009, P = .208). Conclusion: In general, PCO scores and the rate of Nd:YAG laser capsulotomy were influenced by intraocular lens biomaterial. Lens made of hydrophobic biomaterial were overall superior in lowering the PCO score and the Nd:YAG laser capsulotomy rate, but not visual acuity. PMID:29095259

  14. Development of fibrin-free intraocular lens with photochemical surface modification

    NASA Astrophysics Data System (ADS)

    Sato, Yuji; Tanizawa, Katsuya; Anai, Hiroyuki; Sato, Nobuhiro; Sato, Yuki; Ajiki, Tooru; Parel, Jean-Marie; Murahara, Masataka

    2004-07-01

    Having substituted the hydrophilic and hydrophobic groups alternately on the soft acrylic resin intraocular lens (IOL) surface by using an ArF excimer laser and a Xe2 excimer lamp, we have developed the IOL that is free from fibrin. Acrylic resin or PMMA lens has been used as an intraocular lens for 50 years. However, protein and fat are stuck onto the IOL surface after a long implantation, which opacifies the surface (after-cataract). Thus, we designed the micro domain structures of hydrophilic and hydrophobic groups on the IOL surface for fibrin-free. Firstly, the IOL was irradiated with the Xe2 excimer lamp in the presence of perfluoropolyether in order to make it hydrophobic. By this photochemical reaction, the CF3 functional groups were substituted on the IOL surface. Secondly, the ArF laser was projected on the IOL through the mask pattern in reduced size in the presence of water in order to be hydrophilic. With the photochemical reaction, the OH groups were substituted at the part exposed. The fibrin adsorption test of the modified IOL surface was carried out with FT-IR; which revealed that the fibrin-sticking rate of the treated sample has decreased by 23% compared with that of the non-treated sample. As a result, the fibrin-free IOL has been made by modifying the surface of the IOL to have the micro domain structures of the hydrophilic and hydrophobic groups that are arrayed alternately. In conclusion, the ideal intraocular lens has been demonstrated.

  15. History and development of the apodized diffractive intraocular lens.

    PubMed

    Davison, James A; Simpson, Michael J

    2006-05-01

    The ReSTOR intraocular lens presents a unique apodized diffractive design within a refractive foldable acrylic optic, which makes an unprecedented level of mulifocal optical performance available. We describe the history and principles of diffractive optics used in the development of this refractive-diffractive IOL.

  16. Intraocular lens power estimation by accurate ray tracing for eyes underwent previous refractive surgeries

    NASA Astrophysics Data System (ADS)

    Yang, Que; Wang, Shanshan; Wang, Kai; Zhang, Chunyu; Zhang, Lu; Meng, Qingyu; Zhu, Qiudong

    2015-08-01

    For normal eyes without history of any ocular surgery, traditional equations for calculating intraocular lens (IOL) power, such as SRK-T, Holladay, Higis, SRK-II, et al., all were relativley accurate. However, for eyes underwent refractive surgeries, such as LASIK, or eyes diagnosed as keratoconus, these equations may cause significant postoperative refractive error, which may cause poor satisfaction after cataract surgery. Although some methods have been carried out to solve this problem, such as Hagis-L equation[1], or using preoperative data (data before LASIK) to estimate K value[2], no precise equations were available for these eyes. Here, we introduced a novel intraocular lens power estimation method by accurate ray tracing with optical design software ZEMAX. Instead of using traditional regression formula, we adopted the exact measured corneal elevation distribution, central corneal thickness, anterior chamber depth, axial length, and estimated effective lens plane as the input parameters. The calculation of intraocular lens power for a patient with keratoconus and another LASIK postoperative patient met very well with their visual capacity after cataract surgery.

  17. Symbolic algebra approach to the calculation of intraocular lens power following cataract surgery

    NASA Astrophysics Data System (ADS)

    Hjelmstad, David P.; Sayegh, Samir I.

    2013-03-01

    We present a symbolic approach based on matrix methods that allows for the analysis and computation of intraocular lens power following cataract surgery. We extend the basic matrix approach corresponding to paraxial optics to include astigmatism and other aberrations. The symbolic approach allows for a refined analysis of the potential sources of errors ("refractive surprises"). We demonstrate the computation of lens powers including toric lenses that correct for both defocus (myopia, hyperopia) and astigmatism. A specific implementation in Mathematica allows an elegant and powerful method for the design and analysis of these intraocular lenses.

  18. Suturing technique for scleral fixation of toric intraocular lens in the traumatic aphakic eye with corneal astigmatism.

    PubMed

    Pan, Qintuo; Yang, Zhengwei; Chen, Xiaomeng; Wei, Wenlong; Ke, Zhisheng; Chen, Ding; Huang, Fang; Cai, Junyong; Zhao, Zhenquan

    2018-04-01

    To describe the clinical outcomes of traumatic aphakic eyes with corneal astigmatism after using a novel technique for toric intraocular lens suture fixation. In total, 12 eyes of 12 patients who underwent a new scleral suture fixation technique of one-piece toric intraocular lens (SN6AT series, Alcon Inc., TX, USA) were included in our retrospective study. Preoperative patient status, postoperative visual acuity and refractive outcomes, postoperative intraocular lens rotation, tilt, decentration, and complications were analyzed. The mean follow-up was 11.6 ± 1.0 months. The mean preoperative best-corrected visual acuity was 0.55 ± 0.32 in the logarithm of minimum angle of resolution equivalent; the postoperative best-corrected visual acuity was 0.45 ± 0.34. The mean preoperative total corneal astigmatism was 2.51 ± 1.67 D. The mean postoperative residual astigmatism was 0.77 ± 0.54 D. The mean intraocular lens rotation was 3.33° ± 1.37° (range, 1°-6°). The mean intraocular lens tilt in horizontal direction was 3.64° ± 1.02° (range, 2.6°-6.3°) and in vertical direction it was 3.19° ± 1.07 ° (range, 1.6°-5.2°). The mean intraocular lens decentration in horizontal direction was 0.14 ± 0.03 mm (range, 0.089-0.192 mm) and in vertical direction it was 0.15 ± 0.02 mm (range, 0.113-0.181 mm). One patient had mild vitreous hemorrhage and two other patients had high postoperative residual sphere and astigmatism, respectively. But no other serious complications were observed. Scleral suture fixation of foldable toric intraocular lens to correct corneal astigmatism can be a safe and effective alternative technique to manage traumatic aphakic eyes that lack adequate capsular support.

  19. Neodymium:YAG laser cutting of intraocular lens haptics.

    PubMed

    Gorn, R A; Steinert, R F

    1985-11-01

    Neodymium:YAG laser cutting of polymethylmethacrylate and polypropylene anterior chamber and posterior chamber intraocular lens haptics was studied in terms of ease of transection and physical structure of the cut areas as seen by scanning electron microscopy. A marked difference was discovered, with the polymethylmethacrylate cutting easily along transverse planes, whereas the polypropylene resisted cutting along longitudinal fibers. Clinical guidelines are presented.

  20. Advanced pigment dispersion glaucoma secondary to phakic intraocular collamer lens implant.

    PubMed

    Ye, Clara; Patel, Cajal K; Momont, Anna C; Liu, Yao

    2018-06-01

    We report a case of pigment dispersion glaucoma secondary to uncomplicated phakic intraocular collamer lens (ICL) (Visian ICL™, Staar Inc., Monrovia, CA) implant that resulted in advanced visual field loss. A 50-year-old man presented for routine follow-up status post bilateral phakic intraocular collamer lens (ICL) placement 8 years earlier. He was incidentally found to have a decline in visual acuity from an anterior subcapsular cataract and elevated intraocular pressure (IOP) in the left eye. There were signs of pigment dispersion and no evidence of angle closure. Diffuse optic nerve thinning was consistent with advanced glaucomatous visual field defects. Pigment dispersion was also present in the patient's right eye, but without elevated IOP or visual field defects. The patient was treated with topical glaucoma medications and the phakic ICL in the left eye was removed concurrently with cataract surgery to prevent further visual field loss. Pigment dispersion glaucoma is a serious adverse outcome after phakic ICL implantation and regular post-operative monitoring may prevent advanced visual field loss.

  1. Effects of blue light-filtering intraocular lenses on the macula, contrast sensitivity, and color vision after a long-term follow-up.

    PubMed

    Kara-Junior, Newton; Espindola, Rodrigo F; Gomes, Beatriz A F; Ventura, Bruna; Smadja, David; Santhiago, Marcony R

    2011-12-01

    To evaluate the possible side effects and potential protection 5 years after implantation of an intraocular lens (IOL) with a blue-light filter (yellow tinted). Ophthalmology Department, University of São Paulo, São Paulo, Brazil. Prospective randomized clinical study. Patients with bilateral visually significant cataract randomly received an ultraviolet (UV) and blue light-filtering IOL (Acrysof Natural SN60AT) in 1 eye and an acrylic UV light-filtering only IOL (Acrysof SA60AT) in the fellow eye. The primary outcome measures were contrast sensitivity, color vision, and macular findings 5 years after surgery. The study enrolled 60 eyes of 30 patients. There were no significant clinical or optical coherence tomography findings in terms of age-related macular degeneration in any eye. There were no statistically significant differences in central macular thickness between the 2 IOL groups (P=.712). There were also no significant between-group differences under photopic or scotopic conditions at any spatial frequency studied. No statistically significant differences in the color discrimination test were found between the 2 IOL groups (P=.674). After 5 years, there were no significant differences in color perception, scotopic contrast sensitivity, or photopic contrast sensitivity between the blue light-filtering (yellow-tinted) IOL and the IOL with a UV-light filter only (untinted). The potential advantage of the tinted IOL in providing protection to macular cells remains unclear. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  2. Intracapsular lensectomy and sulcus intraocular lens fixation in dogs with primary lens luxation or subluxation.

    PubMed

    Stuhr, Charles M; Schilke, Hillary K; Forte, Christina

    2009-01-01

    To evaluate the postoperative results of lensectomy and sulcus intraocular lens fixation (SIOLF) via an ab interno approach in dogs with progressive lens subluxation or early luxation. Retrospective study. Twenty eyes from 19 dogs presented to the Animal Eye Clinic for lens luxation or subluxation between 1999 and 2006. Medical records were reviewed to evaluate preoperative lens position, vision status, intraocular pressure (IOP), and whether surgery was performed on an emergent or elective nature. Lensectomy and SIOLF were performed and postoperative status including vision, glaucoma, and retinal detachment was assessed. Average age was 8.6 years (range 4-14 years) and 55% (11/20) were terriers. Patients were followed a mean of 29.2 months (range 1-92 months) after surgery. Retinal detachment or secondary glaucoma was observed in 1 of 20 (5%) and 5 of 20 (20%) eyes, respectively, with 1 of 20 (5%) exhibiting both. Mean preoperative IOP was 16 mmHg and preoperative lens position was equally divided between luxated and subluxated lenses. Surgery was performed more frequently as an elective procedure (18/20; 90%) due to normalized IOP vs. an emergency procedure (2/20; 10%). Vision was retained in 70% (14/20) of eyes with a mean time to vision loss of 41 months in the remaining eyes due to glaucoma, retinal detachment, or retinal degeneration. Complications of glaucoma and retinal detachment after SIOLF in this study were less when compared with previously reported incidence rates in the literature for lensectomy alone which may reflect improved patient selection.

  3. The Visual Effects of Intraocular Colored Filters

    PubMed Central

    Hammond, Billy R.

    2012-01-01

    Modern life is associated with a myriad of visual problems, most notably refractive conditions such as myopia. Human ingenuity has addressed such problems using strategies such as spectacle lenses or surgical correction. There are other visual problems, however, that have been present throughout our evolutionary history and are not as easily solved by simply correcting refractive error. These problems include issues like glare disability and discomfort arising from intraocular scatter, photostress with the associated transient loss in vision that arises from short intense light exposures, or the ability to see objects in the distance through a veil of atmospheric haze. One likely biological solution to these more long-standing problems has been the use of colored intraocular filters. Many species, especially diurnal, incorporate chromophores from numerous sources (e.g., often plant pigments called carotenoids) into ocular tissues to improve visual performance outdoors. This review summarizes information on the utility of such filters focusing on chromatic filtering by humans. PMID:24278692

  4. Comparison of hydrophobic and hydrophilic intraocular lens in preventing posterior capsule opacification after cataract surgery: An updated meta-analysis.

    PubMed

    Zhao, Yang; Yang, Ke; Li, Jiaxin; Huang, Yang; Zhu, Siquan

    2017-11-01

    Posterior capsular opacification (PCO) is a common long-term complication of cataract surgery. Intraocular lens design and material have been implicated in influencing the development of PCO. This study evaluated the association of hydrophobic and hydrophilic intraocular lenses on preventing PCO. Medline, Cochrane, EMBASE, and Google Scholar databases were searched until August 3, 2016, using the following search terms: cataract, posterior capsule opacification, and intraocular lens. Eligible studies included randomized controlled trials (RCTs), retrospective, and cohort studies. Eleven studies were included in the study with a total of 889 eyes/patients. The overall analysis revealed that hydrophobic intraocular lenses were associated with lower Nd:YAG laser capsulotomy rates than hydrophilic lenses [odds ratio (OR) = 0.38, 95% confidence interval (95% CI) = 0.16-0.91, P = .029]. Hydrophobic intraocular lenses were also associated with lower subjective PCO score (diff. in means: -1.32, 95% CI = -2.39 to -0.25, P = .015) and estimated PCO score (diff. in means: -2.23; 95% CI, -3.80 to -0.68, P = .005) as compared with hydrophilic lenses. Objective PCO score was similar between lens types. (diff. in means: -0.075; 95% CI, -0.18 to 0.035; P = .182). Pooled analysis found that visual acuity was similar between hydrophobic and hydrophilic intraocular lenses (diff. in means: -0.016; 95% CI, -0.041 to 0.009, P = .208). In general, PCO scores and the rate of Nd:YAG laser capsulotomy were influenced by intraocular lens biomaterial. Lens made of hydrophobic biomaterial were overall superior in lowering the PCO score and the Nd:YAG laser capsulotomy rate, but not visual acuity.

  5. The relationship between morphological changes of lens epithelial cells and intraocular lens optic material.

    PubMed

    Majima, K

    1998-01-01

    To examine the morphological changes of lens epithelial cells (LECs) occurring directly beneath and at regions contacting various intraocular lens (IOL) optic materials, human LECs were cultured on human anterior lens capsules and were further incubated upon placing above the cells lens optics made of polymethylmethacrylate, silicone, and soft acrylic material. Observations as to the morphological changes of LECs under phase-contrast microscope and scanning electron microscope were performed on the 14th day of incubation. Gatherings of LECs were observed at regions contacting the soft acrylic material under phase-contrast microscope, and gatherings of LECs were observed accurately at the same regions mentioned above under scanning electron microscope. On the other hand, LECs in contact with two other optic materials did not show morphological changes. The results suggest that LECs attached to and proliferated on not only the anterior lens capsules but also the soft acrylic IOL optics. The model used in this study may be useful in studying the relationship between cellular movement of LECs and IOL optic material.

  6. Spectral analysis and comparison of mineral deposits forming in opacified intraocular lens and senile cataractous lens

    NASA Astrophysics Data System (ADS)

    Lin, Shan-Yang; Chen, Ko-Hwa; Lin, Chih-Cheng; Cheng, Wen-Ting; Li, Mei-Jane

    2010-10-01

    This preliminary report was attempted to compare the chemical components of mineral deposits on the surfaces of an opacified intraocular lens (IOL) and a calcified senile cataractous lens (SCL) by vibrational spectral diagnosis. An opacified intraocular lens (IOL) was obtained from a 65-year-old male patient who had a significant decrease in visual acuity 2-years after an ocular IOL implantation. Another SCL with grayish white calcified plaque on the subcapsular cortex was isolated from a 79-year-old male patient with complicated cataract after cataract surgery. Optical light microscope was used to observe both samples and gross pictures were taken. Fourier transform infrared (FT-IR) and Raman microspectroscopic techniques were employed to analyze the calcified deposits. The curve-fitting algorithm using the Gaussian function was also used to quantitatively estimate the chemical components in each deposit. The preliminary results of spectral diagnosis indicate that the opacified IOL mainly consisted of the poorly crystalline, immature non-stoichiometric hydroxyapatite (HA) with higher content of type B carbonated apatites. However, the calcified plaque deposited on the SCL was comprised of a mature crystalline stoichiometric HA having higher contents of type A and type B carbonate apatites. More case studies should be examined in future.

  7. Intraocular Lens Use in an Astronaut During Long Duration Spaceflight.

    PubMed

    Mader, Thomas H; Gibson, C Robert; Schmid, Josef F; Lipsky, William; Sargsyan, Ashot E; Garcia, Kathleen; Williams, Jeffrey N

    2018-01-01

    The purpose of this paper is to report the first use of an intraocular lens (IOL) in an astronaut during long duration spaceflight (LDSF). An astronaut developed a unilateral cataract and underwent phacoemulsification with insertion of an acrylic IOL. Approximately 15 mo later he flew on a Soyuz spacecraft to the International Space Station (ISS), where he successfully completed a 6-mo mission. Ocular examination, including ultrasound (US), was performed before, during, and after his mission and he was questioned regarding visual changes during each portion of his flight. We documented no change in IOL position during his space mission. This astronaut reported excellent and stable vision during liftoff, entry into microgravity (MG), 6 mo on the ISS, descent, and landing. Our results suggest that modern IOLs are stable, effective, and well tolerated during LDSF.Mader TH, Gibson CR, Schmid JF, Lipsky W, Sargsyan AE, Garcia K, Williams JN. Intraocular lens use in an astronaut during long duration spaceflight. Aerosp Med Hum Perform. 2018; 89(1):63-65.

  8. Visual performance after the implantation of a new trifocal intraocular lens

    PubMed Central

    Vryghem, Jérôme C; Heireman, Steven

    2013-01-01

    Purpose To evaluate the subjective and objective visual results after the implantation of a new trifocal diffractive intraocular lens. Methods A new trifocal diffractive intraocular lens was designed combining two superimposed diffractive profiles: one with +1.75 diopters (D) addition for intermediate vision and the other with +3.50 D addition for near vision. Fifty eyes of 25 patients that were operated on by one surgeon are included in this study. The uncorrected and best distance-corrected monocular and binocular, near, intermediate, and distance visual acuities, contrast sensitivity, and defocus curves were measured 6 months postoperatively. In addition to the standard clinical follow-up, a questionnaire evaluating individual satisfaction and quality of life was submitted to the patients. Results The mean age of patients at the time of surgery was 70 ± 10 years. The mean uncorrected and corrected monocular distance visual acuity (VA) were LogMAR 0.06 ± 0.10 and LogMAR 0.00 ± 0.08, respectively. The outcomes for the binocular uncorrected distance visual acuity were almost the same (LogMAR −0.04 ± 0.09). LogMAR −010 ± 0.15 and 0.02 ± 0.06 were measured for the binocular uncorrected intermediate and near VA, respectively. The distance-corrected visual acuity was maintained in mesopic conditions. The contrast sensitivity was similar to that obtained after implantation of a bifocal intraocular lens and did not decrease in mesopic conditions. The binocular defocus curve confirms good VA even in the intermediate distance range, with a moderate decrease of less than LogMAR 0.2 at −1.5 D, with respect to the best distance VA at 0 D defocus. Patient satisfaction was high. No discrepancy between the objective and subjective outcomes was evidenced. Conclusion The introduction of a third focus in diffractive multifocal intraocular lenses improves the intermediate vision with minimal visual discomfort for the patient. PMID:24124348

  9. Technology needs for the development of the accommodative intraocular lens

    NASA Astrophysics Data System (ADS)

    Nishi, Okihiro

    2010-02-01

    Refilling the lens capsule while preserving capsular integrity offers the potential to restore ocular accommodation. There are two persisting problems in capsular bag refilling for possible clinical application: Leakage of the injectable material through the capsular opening and capsular opacification. Numerous attempts for solving these cardinal problems have not been proven to be clinically applicable. Recently, we developed a novel capsular bag refilling procedure using a novel accommodative intraocular lens that serves as an optic as well as a plug for sealing the capsular opening. The procedure and the results of monkey experiments will be presented.

  10. High Refractive Index Polysiloxane as Injectable, In Situ Curable Accommodating Intraocular Lens

    PubMed Central

    Hao, Xiaojuan; Jeffery, Justine L.; Le, Tam P.T.; McFarland, Gail; Johnson, Graham; Mulder, Roger J.; Garrett, Qian; Manns, Fabrice; Nankivil, Derek; Arrieta, Esdras; Ho, Arthur; Parel, Jean-Marie; Hughes, Timothy C.

    2012-01-01

    Functionalised siloxane macromonomers, with properties designed for application as an injectable, in situ curable accommodating intraocular lens (A-IOL), were prepared via reequilibration of a phenyl group-containing polysiloxane of very high molecular weight with octamethylcyclotetrasiloxane (D4) and 2,4,6,8-tetra(n-propyl-3-methacrylate)-2,4,6,8-tetramethylcyclotetrasiloxane (D4AM) in toluene using trifluoromethanesulfonic acid as a catalyst. Hexaethyldisiloxane was used as an end group to control the molecular weight of the polymer. The generated polymers had a consistency suitable for injection into the empty lens capsule. The polymers contained a low ratio of polymerisable groups so that, in the presence of a photo-initiator, they could be cured on demand in situ within 5 minutes under irradiation of blue light to form an intraocular lens within the lens capsule. All resulting polysiloxane soft gels had a low elastic modulus and thus should be able to restore accommodation. The pre-cure viscosity and post-cure modulus of the generated polysiloxanes were controlled by the end group and D4AM concentrations respectively in the re-equilibration reactions. The refractive index could be precisely controlled by adjusting the aromatic ratio in the polymer to suit such application as an artificial lens. Lens stretching experiments with both human and non-human primate cadaver lenses of different ages refilled with polysiloxane polymers provided a significant increase in amplitude of accommodation (up to 4 D more than that of the respective natural lens). Both in vitro cytotoxicity study using L929 cell lines and in vivo biocompatibility study in rabbit models demonstrated the non-cytotoxicity and ocular biocompatibility of the polymer. PMID:22594975

  11. Lessons learned: wrong intraocular lens.

    PubMed

    Schein, Oliver D; Banta, James T; Chen, Teresa C; Pritzker, Scott; Schachat, Andrew P

    2012-10-01

    To report cases involving the placement of the wrong intraocular lens (IOL) at the time of cataract surgery where human error occurred. Retrospective small case series, convenience sample. Seven surgical cases. Institutional review of errors committed and subsequent improvements to clinical protocols. Lessons learned and changes in procedures adapted. The pathways to a wrong IOL are many but largely reflect some combination of poor surgical team communication, transcription error, lack of preoperative clarity in surgical planning or failure to match the patient, and IOL calculation sheet with 2 unique identifiers. Safety in surgery involving IOLs is enhanced both by strict procedures, such as an IOL-specific "time-out," and the fostering of a surgical team culture in which all members are encouraged to voice questions and concerns. Copyright © 2012 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  12. Combined 23-gauge transconjunctival vitrectomy and scleral fixation of intraocular lens without conjunctival dissection in managing lens complications.

    PubMed

    Yeung, Ling; Wang, Nan-Kai; Wu, Wei-Chi; Chen, Kuan-Jen

    2018-04-23

    To evaluate the safety and efficacy of combined 23-gauge transconjunctival pars plana vitrectomy and scleral fixation of intraocular lens (IOL) without conjunctival dissection. A retrospective study in Chang Gung Memorial Hospital, Keelung and Taoyuan, Taiwan. Patients receiving combined 23-gauge transconjunctival pars plana vitrectomy and scleral fixation of IOL without conjunctival dissection were enrolled. The ocular findings, causes of lens complication, surgical procedures, type of IOL used, and complications were documented. We included 40 eyes from 39 patients (27 male, 12 female) with a mean age of 59.5 [standard deviation (±) 14.8] years old. The mean follow-up duration was 6.8 ± 5.4 months. The cause of lens complications was ocular trauma in 24 (60%) eyes, cataract surgery complications in 11 (28%) eyes, and spontaneous subluxation of crystalline lens in 5 (13%) eyes. The overall best corrected visual acuity (BCVA) (logMAR) improved from 1.359 ± 0.735 to 0.514 ± 0.582 (p < 0.001). The BCVA also improved significantly in each group with different causes of lens complications. Preoperative BCVA was the only factor associated with the postoperative visual outcome (p = 0.008). Most surgery-related complications were self-limited, including mild vitreous hemorrhage (5%), microhyphema (5%), transient elevated intraocular pressure (3%), and transient hypotony (3%). Cystoid macular edema and IOL decentration was found in 3 (8%) eyes and 1 (3%) eye respectively. Combined 23-gauge transconjunctival vitrectomy and scleral fixation of IOL without conjunctival dissection is effective and safe in managing a wide variety of lens complications, with good postoperative comfort and visual recovery. Retrospective study, not applicable.

  13. Simple technique to treat pupillary capture after transscleral fixation of intraocular lens.

    PubMed

    Jürgens, Ignasi; Rey, Amanda

    2015-01-01

    We describe a simple surgical technique to manage pupillary capture after previous transscleral fixation of an intraocular lens. Neither author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  14. Intraocular lens employed for cataract surgery

    NASA Astrophysics Data System (ADS)

    Roszkowska, A. M.; Torrisi, L.

    2014-04-01

    The aim of this paper is to illustrate the techniques of cataract surgery with implantation of intraocular lenses and some physical properties of the used materials. The new technology, coupled with extensive experience and the studied cases, permits to increase the standardization and accuracy of the engravings, by reducing the use and handling of surgical instruments inside the eye. At present it is possible to replace the cataract with crystalline lenses based on biopolymers such as PMMA, silicone, acrylic hydrophilic and hydrophobic acrylic. These materials are increasingly able to replace the natural lens and to ensure the fully functional of the eye. The role of femtosecond lasers in cataract surgery, to assist or replace several aspects of the manual cataract surgery, are discussed.

  15. Asymptomatic snowflake degeneration in a polymethyl methacrylate (PMMA) intraocular lens implant.

    PubMed

    Tan, Lee T; Shuttleworth, Garry N

    2008-01-01

    Snowflake degeneration is a late complication of polymethyl methacrylate (PMMA) intraocular lens implants. We report a case of asymptomatic advanced snowflake opacification presenting 13 years after implantation who maintained a visual acuity of 6/6. This report serves to illustrate the variability of the clinical effects of snowflake degeneration, which do not necessarily correlate with slit-lamp appearances.

  16. Bilateral cataract extraction with posterior chamber intraocular lens implantation simultaneous in pediatric cataracts.

    PubMed

    Caça, Ihsan; Sakalar, Yildirim Bayezit; Ari, Seyhmus; Alakus, Fuat; Dogan, Eyüp

    2008-01-01

    We evaluated the results of simultaneous bilateral cataract extraction with intraocular lens (IOL) inplantation 32 pediatric cataract patients. Simultaneous cataract extraction and posterior capsulotomy with anterior vitrectomy and IOL implantation is an effective and safe procedure in bilateral pediatric cataracts treatment.

  17. Refractive Lens Exchange with Multifocal Intraocular Lens for Treatment of Chronic Intermittent Spasm of the Near Reflex

    PubMed Central

    Sallet, Guy

    2017-01-01

    We report the case of an emmetropic 32-year-old female with decreased uncorrected visual acuity and diplopia due to intermittent episodes of spasm of the near reflex. Neurologic, general, and ophthalmic examination could not find an organic cause. Attempts at spontaneous recovery, psychogenic therapy, and cycloplegic therapy were unsuccessful and the symptoms persisted for almost 5 years, leading to psychogenic distress. Final treatment with refractive lens exchange and implantation of a toric trifocal intraocular lens resolved the spasm of the near reflex, resulting in an uncorrected distance and near visual acuity of 20/20. PMID:29422856

  18. Transient anterior subcapsular vacuolar change of the crystalline lens in patients after posterior chamber phakic intraocular lens implantation.

    PubMed

    Chung, Jin Kwon; Shin, Jin Hee; Lee, Sung Jin

    2013-10-25

    We present two cases of transient vacuolar changes in the anterior subcapsular space of the crystalline lens in patients after posterior chamber phakic intraocular lens implantation. Implantable collamer lenses (ICL) were implanted in healthy myopic patients. Vacuolar changes developed just after the irrigating procedure through the narrow space between the ICL and the crystalline lens. Slit-lamp examinations and spectral domain optical coherence tomography showed bleb-like lesions in the anterior subcapsular space of one eye in each case, though the lesions gradually improved without visual deterioration. Consequently, the lesions turned into a few anterior subcapsular small faint opacities. Direct irrigation of the narrow space confined by the ICL and the crystalline lens is at risk for the development of vacuolar changes in the crystalline lens. The observed spontaneous reversal indicates that surgeons should not rush to surgical intervention but rather opt for close follow over several weeks.

  19. Comparison of a new refractive multifocal intraocular lens with an inferior segmental near add and a diffractive multifocal intraocular lens.

    PubMed

    Alio, Jorge L; Plaza-Puche, Ana B; Javaloy, Jaime; Ayala, María José; Moreno, Luis J; Piñero, David P

    2012-03-01

    To compare the visual acuity outcomes and ocular optical performance of eyes implanted with a multifocal refractive intraocular lens (IOL) with an inferior segmental near add or a diffractive multifocal IOL. Prospective, comparative, nonrandomized, consecutive case series. Eighty-three consecutive eyes of 45 patients (age range, 36-82 years) with cataract were divided into 2 groups: group A, 45 eyes implanted with Lentis Mplus LS-312 (Oculentis GmbH, Berlin, Germany); group B, 38 eyes implanted with diffractive IOL Acri.Lisa 366D (Zeiss, Oberkochen, Germany). All patients underwent phacoemulsification followed by IOL implantation in the capsular bag. Distance corrected, intermediate, and near with the distance correction visual acuity outcomes and contrast sensitivity, intraocular aberrations, and defocus curve were evaluated postoperatively during a 3-month follow-up. Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected near visual acuity (UNVA), corrected distance near and intermediate visual acuity (CDNVA), contrast sensitivity, intraocular aberrations, and defocus curve. A significant improvement in UDVA, CDVA, and UNVA was observed in both groups after surgery (P ≤ 0.04). Significantly better values of UNVA (P<0.01) and CDNVA (P<0.04) were found in group B. In the defocus curve, significantly better visual acuities were present in eyes in group A for intermediate vision levels of defocus (P ≤ 0.04). Significantly higher amounts of postoperative intraocular primary coma and spherical aberrations were found in group A (P<0.01). In addition, significantly better values were observed in photopic contrast sensitivity for high spatial frequencies in group A (P ≤ 0.04). The Lentis Mplus LS-312 and Acri.Lisa 366D IOLs are able to successfully restore visual function after cataract surgery. The Lentis Mplus LS-312 provided better intermediate vision and contrast sensitivity outcomes than the Acri.Lisa 366D. However, the

  20. [Fabrication and Performance Study of Polydimethylsiloxane Intraocular Lens].

    PubMed

    Du, Qiuyue; Yu, Yueqing

    2016-10-01

    To simplify the production process of intraocular lens(IOL)and to solve the problem of lacking adjustable ability,we proposed a novel soft IOL with large-scale adjustable ability and rigid haptics based on heat-assisted method,and gravity-assisted method.Polydimethylsiloxane(PDMS)and rigid material--polymethyl methacrylate(PMMA)were used as the materials for fabricating optical lens(PDMS)and haptics(PDMS and PMMA)through changing the weight ratio of the solution.A lens-smartphone microscopy system was established to replace the traditional digital microscopy to measure the tiny displacements and shape changes.The PDMS lens has excellent optical property through an experiment in which the maximum optical power was around 273.2D.Experimental results indicated that the maximum optical power of PMMA IOL was 129.3D,and that in PDMS IOL,however,was only 56.0D.Thus,the rigid PMMA-IOL has a larger adjustable range.The production process of PDMS was mold-free,rapid,real-time,and highly repeatable and there was no need for a rigorous experimental environment either.This creative processing technology reduced the manufacturing steps from which an optical lens with high transmittance and high resolution,as well as hatics with accurate dimensions,were obtained.The rigidity of haptics affected more intensely than other factors did for improving the pre-displacement and changing the appearance of PDMS lens.Even though the rigidity of PMMA haptics is large enough for accommodating,there are many drawbacks during manufacturing.It is unavailable to rapid fabricate IOL using PMMA.Thus,further work will be required to alter the weight ratio of PDMS material,increase the rigidity,and enhance the adjustable ability of PDMS IOL.

  1. Geometric calibration of lens and filter distortions for multispectral filter-wheel cameras.

    PubMed

    Brauers, Johannes; Aach, Til

    2011-02-01

    High-fidelity color image acquisition with a multispectral camera utilizes optical filters to separate the visible electromagnetic spectrum into several passbands. This is often realized with a computer-controlled filter wheel, where each position is equipped with an optical bandpass filter. For each filter wheel position, a grayscale image is acquired and the passbands are finally combined to a multispectral image. However, the different optical properties and non-coplanar alignment of the filters cause image aberrations since the optical path is slightly different for each filter wheel position. As in a normal camera system, the lens causes additional wavelength-dependent image distortions called chromatic aberrations. When transforming the multispectral image with these aberrations into an RGB image, color fringes appear, and the image exhibits a pincushion or barrel distortion. In this paper, we address both the distortions caused by the lens and by the filters. Based on a physical model of the bandpass filters, we show that the aberrations caused by the filters can be modeled by displaced image planes. The lens distortions are modeled by an extended pinhole camera model, which results in a remaining mean calibration error of only 0.07 pixels. Using an absolute calibration target, we then geometrically calibrate each passband and compensate for both lens and filter distortions simultaneously. We show that both types of aberrations can be compensated and present detailed results on the remaining calibration errors.

  2. [To exercise caution in developing intraocular lens exchange].

    PubMed

    Song, X D; Wang, X Z; Qian, J

    2018-05-11

    Nowadays cataract extraction combined intraocular lens (IOL) implantation has become the conventional treatment for cataract. Numbers of IOL exchange after cataract extraction combined IOL implantation have been increasing in recent years. As a non-routine surgery, IOL exchange is normally combined with other surgeries and accompanied by some complications to various extents. Is IOL exchange necessary for all abnomal IOLs? Can IOL exchange be avoided? How to avoid IOL exchange? The purpose of this article is to stress the importance of indication of IOL exchange and how to avoid IOL exchange. (Chin J Ophthalmol, 2018, 54: 324-327) .

  3. Cataract and keratoconus: minimizing complications in intraocular lens calculations.

    PubMed

    Bozorg, Sara; Pineda, Roberto

    2014-01-01

    Patients with both cataract and keratoconus present unique challenges for the surgeon. Accurate keratometry (K) and axial length (AL) readings may be impossible, and uncertainty is introduced when estimating the corneal power for intraocular lens (IOL) selection. Different options on how to choose an IOL and how to manage irregular astigmatism of a keratoconic patient with cataract have been proposed and are reviewed. The stage of keratoconus and the history of the patient are both critical in determining the strategy used in treatment of cataracts.

  4. Pigment dispersion and chronic intraocular pressure elevation after sulcus placement of 3-piece acrylic intraocular lens.

    PubMed

    Almond, M Camille; Wu, Michael C; Chen, Philip P

    2009-12-01

    A 55-year-old man had phacoemulsification and implantation of a 3-piece acrylic intraocular lens (IOL) (AcrySof MA60AC) in the right eye. One month postoperatively, the intraocular pressure (IOP) was 48 mm Hg and peripheral transillumination defects were noted in the iris circumferentially, with the IOL optic edge visible as a silhouette. Gonioscopy showed dense pigmentation of the trabecular meshwork in the right eye, but in the left eye, only mild trabecular meshwork pigment was seen, along with a concave peripheral iris insertion. At 21 months, the right eye required 3 medications for IOP control. While pigment dispersion has been widely reported after placement of 1-piece acrylic IOLs in the ciliary sulcus, we conclude that in susceptible individuals with a concave peripheral iris insertion, pigment dispersion can occur with sulcus placement of a 3-piece acrylic model despite its thinner optic and angulated haptics.

  5. [Spectral transmission in blue filter intraocular lenses].

    PubMed

    Schrage, N

    2012-02-01

    There is uncertainty in ophthalmology concerning the quality and spectral transmission of light of so-called blue filter intraocular lenses (IOL). Clinical users have noticed that such IOL's appear to have different color intensities. The discussion on medical changes by means of such IOL's is dependent on the real light transmission of these IOL's. To add some objective data we compared these IOL's by systematic transmission measurements and observed technical differences of diffraction and geometry as well as transmission differences. The result gives objective indications that differences between blue filter IOL's from different manufacturers are important and are detailed in this paper.

  6. Early opacification and subsequent in vivo clearing of a silicone intraocular lens.

    PubMed

    Nikrooyan, Idean; Anderson, Justin E

    2011-09-01

    To report a case of early opacification and spontaneous in vivo clearing of a silicone intraocular lens (IOL). A 79-year-old women underwent uncomplicated cataract extraction and subsequent implantation of a +21.5 D AMO Z9002 (Abbott Medical Optics, Santa Ana, CA) silicone lens. On postoperative day 1, the patient presented with a translucent, milky white appearing, diffuse IOL opacification. On postoperative day 8, the IOL periphery had cleared, but a full thickness haze persisted in the central portion of the optic. By postoperative day 14, the IOL had cleared. To date, the lens has remained clear. One possible mechanism might be exposure to industrial chemicals; however, the manufacturer reports no other similar lens opacities from this manufacturing batch of IOLs. We recommend that surgeons who implant or have implanted an AMO Z9002 silicone IOL and observe similar findings follow the patient closely for resolution of the haze.

  7. Biomechanical properties of crystalline lens as a function of intraocular pressure assessed noninvasively by optical coherence elastography

    NASA Astrophysics Data System (ADS)

    Wu, Chen; Aglyamov, Salavat R.; Liu, Chih-Hao; Han, Zhaolong; Singh, Manmohan; Larin, Kirill V.

    2017-02-01

    Many ocular diseases such as glaucoma and uveitis can lead to the elevation of intraocular pressure (IOP). Previous research implies a link between elevated IOP and lens disease. However, the relationship between IOP elevation and biomechanical properties of the crystalline lens has not been directly studied yet. In this work, we investigated the biomechanical properties of porcine lens as a function of IOP by acoustic radiation force optical coherence elastography.

  8. Fluoride coatings for vacuum ultraviolet reflection filters.

    PubMed

    Guo, Chun; Kong, Mingdong; Lin, Dawei; Li, Bincheng

    2015-12-10

    LaF3/MgF2 reflection filters with a high spectral-discrimination capacity of the atomic-oxygen lines at 130.4 and 135.6 nm, which were employed in vacuum ultraviolet imagers, were prepared by molybdenum-boat thermal evaporation. The optical properties of reflection filters were characterized by a high-precision vacuum ultraviolet spectrophotometer. The vulnerability of the filter's microstructures to environmental contamination and the recovery of the optical properties of the stored filter samples with ultraviolet ozone cleaning were experimentally demonstrated. For reflection filters with the optimized nonquarter-wave multilayer structures, the reflectance ratios R135.6 nm/R130.4 nm of 92.7 and 20.6 were achieved for 7° and 45° angles of incidence, respectively. On the contrary, R135.6 nm/R130.4 nm ratio of 12.4 was obtained for a reflection filter with a standard π-stack multilayer structure with H/L=1/4 at 7° AOI.

  9. Spectral transmission of the pig lens: effect of ultraviolet A+B radiation.

    PubMed

    Artigas, C; Navea, A; López-Murcia, M-M; Felipe, A; Desco, C; Artigas, J-M

    2014-12-01

    To determine the spectral transmission curve of the crystalline lens of the pig. To analyse how this curve changes when the crystalline lens is irradiated with ultraviolet A+B radiation similar to that of the sun. To compare these results with literature data from the human crystalline lens. We used crystalline lenses of the common pig from a slaughterhouse, i.e. genetically similar pigs, fed with the same diet, and slaughtered at six months old. Spectral transmission was measured with a Perkin-Elmer Lambda 35 UV/VIS spectrometer. The lenses were irradiated using an Asahi Spectra Lax-C100 ultraviolet source, which made it possible to select the spectral emission band as well as the intensity and exposure time. The pig lens transmits all the visible spectrum (95%) and lets part of the ultraviolet A through (15%). Exposure to acute UV (A+B) irradiation causes a decrease in its transmission as the intensity or exposure time increases: this decrease is considerable in the UV region. We were able to determine the mean spectral transmission curve of the pig lens. It appears to be similar to that of the human lens in the visible spectrum, but different in the ultraviolet. Pig lens transmission is reduced by UV (A+B) irradiation and its transmission in the UV region can even disappear as the intensity or exposure time increases. An adequate exposure intensity and time of UV (A+B) radiation always causes an anterior subcapsular cataract (ASC). Copyright © 2014. Published by Elsevier Masson SAS.

  10. Phakic iris-fixated intraocular lens placement in the anterior chamber: effects on aqueous flow.

    PubMed

    Repetto, Rodolfo; Pralits, Jan O; Siggers, Jennifer H; Soleri, Paolo

    2015-05-01

    Phakic intraocular lenses (pIOLs) are used for correcting vision; in this paper we investigate the fluid dynamical effects of an iris-fixated lens in the anterior chamber. In particular, we focus on changes in the wall shear stress (WSS) on the cornea and iris, which could be responsible for endothelial and pigment cell loss, respectively, and also on the possible increase of the intraocular pressure, which is known to correlate with the incidence of secondary glaucoma. We use a mathematical model to study fluid flow in the anterior chamber in the presence of a pIOL. The governing equations are solved numerically using the open source software OpenFOAM. We use an idealized standard geometry for the anterior chamber and a realistic geometric description of the pIOL. We consider separately the main mechanisms that produce fluid flow in the anterior chamber. The numerical simulations allow us to obtain a detailed description of the velocity and pressure distribution in the anterior chamber, and indicated that implantation of the pIOL significantly modifies the fluid dynamics in the anterior chamber. However, lens implantation has negligible influence on the intraocular pressure and does not produce a significant increase of the shear stress on the cornea, while the shear stress on the iris, although increased, is not enough to cause detachment of cells. We conclude that alterations in the fluid dynamics in the anterior chamber as a result of lens implantation are unlikely to be the cause of medical complications associated with its use.

  11. Iris-claw versus posterior chamber fixation intraocular lens implantation in pediatric traumatic cataract☆

    PubMed Central

    Kavitha, V; Balasubramanian, Preethi; Heralgi, Mallikarjun M.

    2016-01-01

    Aim: This study aims to compare visual outcomes and complications of iris-fixated (claw) intraocular lens (IFIOL) implantation with those of posterior chamber intraocular lens (PCIOL) implantation in children with traumatic cataract. Settings and design: Retrospective observational clinical audit. Materials and methods: A total of 50 pediatric traumatic cataract cases that underwent lens removal and IOL implantation (IFIOL or PCIOL) with or without corneal or corneoscleral tear repair between January 2009 and December 2013 were analyzed. After meeting the eligibility criteria, their pre- and postoperative visual outcomes and complication rates were recorded. Data were analyzed descriptively. Results: Out of 50 children, IFIOL and PCIOL implantations were performed in one eye of each of 25 children. Their mean age was 11 ± 4 years (range 4–18 years). Primary (cataract removal with lens implantation) and secondary (corneal tear repair followed by cataract removal with lens implantation) procedures were performed in 19 (76%) and six (24%) children in the IFIOL group and in 21 (84%) and four (16%) children in the PCIOL group, respectively. There was an improvement in best corrected visual acuity postimplantation in both the IFIOL and the PCIOL group, and no significant difference in the logarithm of the minimum angle of resolution of best corrected visual acuity was observed between the two groups over 36 months. Only three eyes in the IFIOL group developed complications: one eye developed secondary glaucoma, one disenclavation of IOL haptic, and one cystoid macular edema. Conclusion: Both IFIOL and PCIOL implantations have good visual outcomes and minimal postoperative complications; therefore, IFIOL can be used as an alternative to PCIOL in children with traumatic cataract with inadequate capsular support. PMID:29018714

  12. Extended depth of focus intraocular lens: Chromatic performance

    PubMed Central

    Millán, Maria S.; Vega, Fidel

    2017-01-01

    We describe a first-and-second-diffractive-order intraocular lens ((1st,2nd)DIOL) within the class of hybrid refractive-diffractive designs for intraocular lenses (IOLs) and analyse its properties of focus extension and compensation of longitudinal chromatic aberration (LCA), particularly for lenses with low addition. Power, energy efficiency and their wavelength dependence are extended from monofocal IOL and conventional bifocal zeroth-and-first-diffractive-order IOL ((0th,1st)DIOL) to (1st,2nd)DIOL of low addition. Compensation of LCA is experimentally assessed in optical bench through the through-focus energy efficiency of three Tecnis IOLs with red, green and blue illuminations: ZA9003 (monofocal), ZKB00 (bifocal (0th,1st)DIOL with + 2.75 D add) and Symfony ZXR00. We prove Tecnis Symfony ZXR00 IOL can be considered an example of (1st,2nd)DIOL design of low addition, with LCA compensation in both the distance and intermediate foci, whereas the bifocal (0th,1st)DIOL does not compensate in the distance focus. However, the energy efficiency of (1st,2nd)DIOL for wavelengths other than the design wavelength is markedly more asymmetric. PMID:28966865

  13. Forces on intraocular lens haptics induced by capsular fibrosis. An experimental study.

    PubMed

    Guthoff, R; Abramo, F; Draeger, J; Chumbley, L C; Lang, G K; Neumann, W

    1990-01-01

    Electronic dynamometry measurements, performed upon intraocular lens (IOL) haptics of prototype one-piece three-loop silicone lenses, accurately defined the relationships between elastic force and haptic displacement. Lens implantations in the capsular bag of dogs (loop span equal to capsular bag diameter, loops underformed immediately after the operation) were evaluated macrophotographically 5-8 months postoperatively. The highly constant elastic property of silicon rubber permitted quantitative correlation of subsequent in vivo haptic displacement with the resultant force vectors responsible for tissue contraction. The lens optics were well centered in 17 (85%) and slightly offcenter in 3 (15%) of 20 implanted eyes. Of the 60 supporting loops, 28 could be visualized sufficiently well to permit reliable haptic measurement. Of these 28, 20 (71%) were clearly displaced, ranging from 0.45 mm away from to 1.4 mm towards the lens' optic center. These extremes represented resultant vector forces of 0.20 and 1.23 mN respectively. Quantitative vector analysis permits better understanding of IOL-capsular interactions.

  14. Corneal edema and permanent blue discoloration of a silicone intraocular lens by methylene blue.

    PubMed

    Stevens, Scott; Werner, Liliana; Mamalis, Nick

    2007-01-01

    To report a silicone intraocular lens (IOL) stained blue by inadvertent intraoperative use of methylene blue instead of trypan blue and the results of experimental staining of various lens materials with different concentrations of the same dye. A "blue dye" was used to enhance visualization during capsulorhexis in a patient undergoing phacoemulsification with implantation of a three-piece silicone lens. Postoperatively, the patient presented with corneal edema and a discolored IOL. Various IOL materials were experimentally stained using methylene blue. Sixteen lenses (4 silicone, 4 hydrophobic acrylic, 4 hydrophilic acrylic, and 4 polymethylmethacrylate) were immersed in 0.5 mL of methylene blue at concentrations of 1%, 0.1%, 0.01%, and 0.001%. These lenses were grossly and microscopically evaluated for discoloration 6 and 24 hours after immersion. The corneal edema resolved within 1 month after the initial surgical procedure. After explantation, gross and microscopic analyses of the explanted silicone lens revealed that its surface and internal substance had been permanently stained blue. In the experimental study, all of the lenses except the polymethylmethacrylate lenses were permanently stained by methylene blue. The hydrophilic acrylic lenses showed the most intense blue staining in all dye concentrations. This is the first clinicopathological report of IOL discoloration due to intraocular use of methylene blue. This and other tissue dyes may be commonly found among surgical supplies in the operating room and due diligence is necessary to avoid mistaking these dyes for those commonly used during ocular surgery.

  15. Iris reconstruction combined with iris-claw intraocular lens implantation for the management of iris-lens injured patients.

    PubMed

    Hu, Shufang; Wang, Mingling; Xiao, Tianlin; Zhao, Zhenquan

    2016-03-01

    To study the efficiency and safety of iris reconstruction combined with iris-claw intraocular lens (IOL) implantation in the patients with iris-lens injuries. Retrospective, noncomparable consecutive case series study. Eleven patients (11 eyes) following iris-lens injuries underwent iris reconstructions combined with iris-claw IOL implantations. Clinical data, such as cause and time of injury, visual acuity (VA), iris and lens injuries, surgical intervention, follow-up period, corneal endothelial cell count, and optical coherence tomography, were collected. Uncorrected VA (UCVA) in all injured eyes before combined surgery was equal to or <20/1000. Within a 1.1-4.2-year follow-up period, a significant increase, equal to or better than 20/66, in UCVA was observed in six (55%) cases, and in best-corrected VA (BCVA) was observed in nine (82%) cases. Postoperative BCVA was 20/40 or better in seven cases (64%). After combined surgery, the iris returned to its natural round shape or smaller pupil, and the iris-claw IOLs in the 11 eyes were well-positioned on the anterior surface of reconstructed iris. No complications occurred in those patients. Iris reconstruction combined with iris-claw IOL implantation is a safe and efficient procedure for an eye with iris-lens injury in the absence of capsular support.

  16. Morphologic compatibility or intraocular lens haptics and the lens capsule.

    PubMed

    Nagamoto, T; Eguchi, G

    1997-10-01

    To evaluate the mechanical relationship between the intraocular lens (IOL) haptic and the capsular bag by quantitatively analyzing the fit of the haptic with the capsule equator and the capsular bag deformity induced by the implanted lens haptics. Division of Morphogenesis, Department of Developmental Biology, National Institute for Basic Biology, Okazaki, Japan. Following implantation of a poly(methyl methacrylate)(PMMA) ring in three excised human capsular bags with continuous curvilinear capsulorhexis (CCC), IOLs with different overall lengths or haptic designs were implanted in the bags and photographed. The straight length of the area of contact between the haptic and the capsule equator on the photographs was measured to provide a quantitative index of in-the-bag fixation and the length from the external margin of the PMMA ring to the external margin of the loop along the maximal diameter of the capsular bag, to indicate the quantitative degree of capsular deformity induced by an IOL. An IOL with modified-C loops produced better fit along the capsule equator and less deformity than an IOL with modified-J loops, and an IOL with an overall length of 12.0 or 12.5 mm produced a sufficiently good fit and less distortion of the capsular bag than an IOL with an overall length over 13.0 mm. An IOL with modified-C loops and an overall length of 12.0 or 12.5 mm is adequate for in-the-bag implantation following CCC.

  17. Blue-light filtering intraocular lenses (IOLs) for protecting macular health.

    PubMed

    Downie, Laura E; Busija, Ljoudmila; Keller, Peter R

    2018-05-22

    An intraocular lens (IOL) is a synthetic lens that is surgically implanted within the eye following removal of the crystalline lens, during cataract surgery. While all modern IOLs attenuate the transmission of ultra-violet (UV) light, some IOLs, called blue-blocking or blue-light filtering IOLs, also reduce short-wavelength visible light transmission. The rationale for blue-light filtering IOLs derives primarily from cell culture and animal studies, which suggest that short-wavelength visible light can induce retinal photoxicity. Blue-light filtering IOLs have been suggested to impart retinal protection and potentially prevent the development and progression of age-related macular degeneration (AMD). We sought to investigate the evidence relating to these suggested benefits of blue-light filtering IOLs, and to consider any potential adverse effects. To assess the effects of blue-light filtering IOLs compared with non-blue-light filtering IOLs, with respect to providing protection to macular health and function. We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (which contains the Cochrane Eyes and Vision Trials Register) (2017, Issue 9); Ovid MEDLINE; Ovid Embase; LILACS; the ISRCTN registry; ClinicalTrials.gov and the ICTRP. The date of the search was 25 October 2017. We included randomised controlled trials (RCTs), involving adult participants undergoing cataract extraction, where a blue-light filtering IOL was compared with an equivalent non-blue-light filtering IOL. The prespecified primary outcome was the change in distance best-corrected visual acuity (BCVA), as a continuous outcome, between baseline and 12 months of follow-up. Prespecified secondary outcomes included postoperative contrast sensitivity, colour discrimination, macular pigment optical density (MPOD), proportion of eyes with a pathological finding at the macula (including, but not limited to the development or progression of AMD, or both), daytime alertness, reaction time

  18. [Long-term results of posterior chamber phakic intraocular lens implantation for correction of high ametropia].

    PubMed

    Le Loir, M; Cochener, B

    2012-06-01

    To assess efficacy, stability and safety of posterior chamber phakic intraocular lens implantation with STAAR Visian ICL for correction of high ametropia, with a mean follow-up of 5 years (3.5-10 years). Ninety eyes of 53 highly ametropic patients (45 myopia, ten hyperopia and 35 with mixed astigmatism) were included in a retrospective single-surgeon study, using primarily the V4 ICL model (87 eyes). We studied pre- and postoperative refractive efficacy, endothelial cell density, crystalline lens opacification and intraocular clearances within the various compartments of the eye. Mean uncorrected visual acuity was 0.77 at the 12th postoperative month; 17 of 90 eyes required adjunctive photoablation for residual astigmatism. Forty-eight percent of eyes gained at least one line of best corrected visual acuity. After implantation, the decrease in endothelial cell density remained stable at 0.69%/year, and 91% of eyes showed no opacification of the crystalline lens. Mean endothelium-ICL and ICL-crystalline lens distances were 2.41 mm and 0.52 mm respectively. Overall patient satisfaction achieved was 96% at 36 months postoperatively. These results demonstrate efficacy, stability and safety of the ICL V4 phakic IOL for the correction of high ametropia. Long-term follow-up did not show a significant increase in cataract formation in implanted eyes. Copyright © 2012. Published by Elsevier Masson SAS.

  19. Engineering hurdles in contact and intraocular lens lathe design: the view ahead

    NASA Astrophysics Data System (ADS)

    Bradley, Norman D.; Keller, John R.; Ball, Gary A.

    1994-05-01

    Current trends in and intraocular lens design suggest ever- increasing demand for aspheric lens geometries - multisurface and/or toric surfaces - in a variety of new materials. As computer numeric controls (CNC) lathes and mills continue to evolve with he ophthalmic market, engineering hurdles present themselves to designers: Can hardware based upon single-point diamond turning accommodate the demands of software-driven designs? What are the limits of CNC resolution and repeatability in high-throughput production? What are the controlling factors in lathed, polish-free surface production? Emerging technologies in the lathed biomedical optics field are discussed along with their limitations, including refined diamond tooling, vibrational control, automation, and advanced motion control systems.

  20. Sectioning a luxated intraocular lens inside the vitreous cavity.

    PubMed

    Vilaplana, Daniel; Pazos, Marta

    2013-07-01

    We describe a new technique for sectioning an intraocular lens (IOL) inside the vitreous cavity. The IOL had a broken haptic and was accidentally luxated after a complicated cataract surgery with posterior capsule rupture. The primary indication to cut the IOL in half inside the vitreous cavity is to preserve the anterior capsule integrity, especially in a small-sized capsulotomy, allowing subsequent implantation of a new IOL in the sulcus with the optical zone captured in the capsulorhexis. Neither author has a financial or proprietary interest in any material or method mentioned. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  1. Surface Modification of Intraocular Lenses

    PubMed Central

    Huang, Qi; Cheng, George Pak-Man; Chiu, Kin; Wang, Gui-Qin

    2016-01-01

    Objective: This paper aimed to review the current literature on the surface modification of intraocular lenses (IOLs). Data Sources: All articles about surface modification of IOLs published up to 2015 were identified through a literature search on both PubMed and ScienceDirect. Study Selection: The articles on the surface modification of IOLs were included, but those on design modification and surface coating were excluded. Results: Technology of surface modification included plasma, ion beam, layer-by-layer self-assembly, ultraviolet radiation, and ozone. The main molecules introduced into IOLs surface were poly (ethylene glycol), polyhedral oligomeric silsesquioxane, 2-methacryloyloxyethyl phosphorylcholine, TiO2, heparin, F-heparin, titanium, titanium nitride, vinyl pyrrolidone, and inhibitors of cytokines. The surface modification either resulted in a more hydrophobic lens, a more hydrophilic lens, or a lens with a hydrophilic anterior and hydrophobic posterior surface. Advances in research regarding surface modification of IOLs had led to a better biocompatibility in both in vitro and animal experiments. Conclusion: The surface modification is an efficient, convenient, economic and promising method to improve the biocompatibility of IOLs. PMID:26830993

  2. Iris reconstruction combined with iris-claw intraocular lens implantation for the management of iris-lens injured patients

    PubMed Central

    Hu, Shufang; Wang, Mingling; Xiao, Tianlin; Zhao, Zhenquan

    2016-01-01

    Aim: To study the efficiency and safety of iris reconstruction combined with iris-claw intraocular lens (IOL) implantation in the patients with iris-lens injuries. Settings and Design: Retrospective, noncomparable consecutive case series study. Materials and Methods: Eleven patients (11 eyes) following iris-lens injuries underwent iris reconstructions combined with iris-claw IOL implantations. Clinical data, such as cause and time of injury, visual acuity (VA), iris and lens injuries, surgical intervention, follow-up period, corneal endothelial cell count, and optical coherence tomography, were collected. Results: Uncorrected VA (UCVA) in all injured eyes before combined surgery was equal to or <20/1000. Within a 1.1–4.2-year follow-up period, a significant increase, equal to or better than 20/66, in UCVA was observed in six (55%) cases, and in best-corrected VA (BCVA) was observed in nine (82%) cases. Postoperative BCVA was 20/40 or better in seven cases (64%). After combined surgery, the iris returned to its natural round shape or smaller pupil, and the iris-claw IOLs in the 11 eyes were well-positioned on the anterior surface of reconstructed iris. No complications occurred in those patients. Conclusions: Iris reconstruction combined with iris-claw IOL implantation is a safe and efficient procedure for an eye with iris-lens injury in the absence of capsular support. PMID:27146932

  3. Design of a Test Bench for Intraocular Lens Optical Characterization

    NASA Astrophysics Data System (ADS)

    Alba-Bueno, Francisco; Vega, Fidel; Millán, María S.

    2011-01-01

    The crystalline lens is the responsible for focusing at different distances (accommodation) in the human eye. This organ grows throughout life increasing in size and rigidity. Moreover, due this growth it loses transparency through life, and becomes gradually opacified causing what is known as cataracts. Cataract is the most common cause of visual loss in the world. At present, this visual loss is recoverable by surgery in which the opacified lens is destroyed (phacoemulsification) and replaced by the implantation of an intraocular lens (IOL). If the IOL implanted is mono-focal the patient loses its natural capacity of accommodation, and as a consequence they would depend on an external optic correction to focus at different distances. In order to avoid this dependency, multifocal IOLs designs have been developed. The multi-focality can be achieved by using either, a refractive surface with different radii of curvature (refractive IOLs) or incorporating a diffractive surface (diffractive IOLs). To analyze the optical quality of IOLs it is necessary to test them in an optical bench that agrees with the ISO119679-2 1999 standard (Ophthalmic implants. Intraocular lenses. Part 2. Optical Properties and Test Methods). In addition to analyze the IOLs according to the ISO standard, we have designed an optical bench that allows us to simulate the conditions of a real human eye. To do that, we will use artificial corneas with different amounts of optical aberrations and several illumination sources with different spectral distributions. Moreover, the design of the test bench includes the possibility of testing the IOLs under off-axis conditions as well as in the presence of decentration and/or tilt. Finally, the optical imaging quality of the IOLs is assessed by using common metrics like the Modulation Transfer Function (MTF), the Point Spread Function (PSF) and/or the Strehl ratio (SR), or via registration of the IOL's wavefront with a Hartmann-Shack sensor and its

  4. Positional and rotational stability of the toric phakic intraocular lens under high +Gz environments.

    PubMed

    Tan, Marcus C L; Nah, Gerard K M

    2012-02-01

    Phakic intraocular lens (PIOL) implantation is a surgical option for correction of refractive errors. PIOLs can be use to correct myopia, hyperopia, and astigmatism. It is a surgical option available to patients in addition to methods such as laser cornea refractive surgery, e.g., laser assisted in-situ keratomileusis (LASIK) and photo-refractive keratectomy (PRK). Visian implantable collamer lens (ICL) are posterior chamber lenses which are surgically positioned in a phakic eye in the sulcus between the iris diaphragm and the natural crystalline lens. This case report describes the stability of Visian toric ICL in a candidate with bilateral implants under high +Gz force exposure in a human centrifuge trainer. The subject was sequentially exposed to three incremental +Gz profiles of +5 Gz, +7 Gz, and +9 Gz. Pre- and post-+Gz exposure, ophthalmic examination revealed no ICL displacement, implant touch or induced cataract, or change in refractive error. The rotational stability of the toric implants was also demonstrated by identical subjective refractions in both eyes taken pre- and post-+Gz, exposure. A search of the literature did not reveal any published articles on intraocular stability of ICL in the +Gz environment. This case report suggests that ICL may be considered an alternative to laser refractive surgery for patients subjected to a high +G, environment such as military aviators.

  5. Better Visual Outcome by Intraocular Lens Ejection in Geriatric Patients with Ruptured Ocular Injuries

    PubMed Central

    Sugita, Tadasu; Tsunekawa, Taichi; Matsuura, Toshiyuki; Takayama, Kei; Yamamoto, Kentaro; Kachi, Shu; Ito, Yasuki; Ueno, Shinji; Nonobe, Norie; Kataoka, Keiko; Suzumura, Ayana; Iwase, Takeshi; Terasaki, Hiroko

    2017-01-01

    Ocular trauma is one of the leading causes of visual impairment worldwide. Because of the popularity of cataract surgeries, aged individuals with ocular trauma commonly have a surgical wound in their eyes. The purpose of this study was to evaluate the visual outcome of cases that were coincident with intraocular lens (IOL) ejection in the eyes with ruptured open-globe ocular injuries. Consecutive patients with open-globe ocular injuries were first reviewed. Patients’ characteristics, corrected distance visual acuities (CDVAs) over 3 years after the trauma, causes of injuries, traumatic wound patterns, and coexistence of retinal detachment were examined. The relationships between poor CDVA and the other factors, including the complications of crystalline lens and IOL ejection, were examined. A total of 105 eyes/patients [43 eyes with rupture, 33 with penetrating, 28 with intraocular foreign body (IOFB), and 1 with perforating injuries] were included. Rupture injuries were common in aged patients and were mostly caused by falls, whereas penetrating and IOFB injuries were common in young male patients. CDVAs of the eyes with rupture injuries were significantly worse than those of the eyes with penetrating or IOFB injuries. CDVA from more than 50% of the ruptured eyes resulted in no light perception or light perception to 20/500. CDVA of the ruptured eyes complicated by crystalline lens ejection was significantly worse than that of those complicated by IOL ejection. The wounds of the ruptured eyes complicated by IOL ejection were mainly located at the superior corneoscleral limbus, whereas those of the eyes complicated by crystalline lens ejection were located at the posterior sclera. There were significant correlations between poor CDVA and retinal detachment and crystalline lens ejection. These results proposed a new trend in the ocular injuries that commonly occur in aged patients; history of cataract surgery might affect the final visual outcome after open

  6. Alcaligenes xylosoxidans endophthalmitis following phacoemulsification and intraocular lens implantation.

    PubMed

    Robert, Pierre-Yves; Chainier, Delphine; Garnier, Fabien; Ploy, Marie-Cécile; Parneix, Pierre; Adenis, Jean-Paul; Martin, Christian

    2008-01-01

    Five consecutive cases of endophthalmitis that developed after cataract extraction by a single surgeon using the same operating room during one morning session are described. Following preoperative topical administration of ciprofloxacin, surgery consisted of phacoemulsification with peristaltic pump and fluid venting, polymethylmethacrylate intraocular lens implantation, and corneal suture. No complications occurred during surgery. All five patients developed endophthalmitis caused by infection with Alcaligenes xylosoxidans in less than 24 hours. Pulsed-field gel electrophoresis was used to prove similarity between strains. Bacterial inquiry on contamination of the operating room environment revealed massive colonization of phacoemulsifier irrigation channels by Pseudomonas fluorescens bacteria from an unestablished source. Four of the five patients ultimately recovered visual acuity better than 20/60.

  7. Clinical outcome and higher order aberrations after bilateral implantation of an extended depth of focus intraocular lens.

    PubMed

    Pilger, Daniel; Homburg, David; Brockmann, Tobias; Torun, Necip; Bertelmann, Eckart; von Sonnleithner, Christoph

    2018-04-01

    The purpose of this study was to assess the clinical outcome after a bilateral implantation of an extended depth of focus intraocular lens in comparison to a monofocal intraocular lens. Department of Ophthalmology, Charité-Medical University Berlin, Germany. A total of 60 eyes of 30 patients were enrolled in this prospective, single-center study. The cataract patients underwent phacoemulsification with bilateral implantation of a TECNIS ® Symfony (Abbott Medical Optics, Santa Ana, CA, USA, 15 patients) or a TECNIS Monofocal ZCB00 (Abbott Medical Optics, Santa Ana, CA, USA, 15 patients). Postoperative evaluations were performed after 1 and 3 months, including visual acuities at far, intermediate, and near distance. Mesopic, scotopic vision, and contrast sensitivity were investigated. Aberrometry was performed using an iTrace aberrometer with a pupil scan size of 5.0 mm. After 3 months, the TECNIS Symfony group reached an uncorrected visual acuity at far distance of -0.02 logMAR compared to -0.06 logMAR in the TECNIS Monofocal group ( p = 0.03). Regarding the uncorrected vision at intermediate and near distance the following values were obtained: intermediate visual acuity -0.13 versus 0.0 logMAR (TECNIS Symfony vs TECNIS Monofocal, p = 0.001) and near visual acuity 0.11 versus 0.26 logMAR (TECNIS Symfony vs TECNIS Monofocal, p = 0.001). Low-contrast visual acuities were 0.27 versus 0.20 logMar (TECNIS Symfony vs TECNIS Monofocal, p = 0.023). The TECNIS Symfony intraocular lens can be considered an appropriate alternative to multifocal intraocular lenses because of good visual results at far, intermediate, and near distance as well as in low-contrast vision.

  8. Vertical fixation with fibrin glue-assisted secondary posterior chamber intraocular lens implantation in a case of surgical aphakia

    PubMed Central

    Ladi, Jeevan S; Shah, Nitant A

    2013-01-01

    We report the first case of vertical fixation by fibrin glue-assisted secondary posterior chamber intraocular lens implantation in a case of surgical aphakia. Advantages of vertical fixation are discussed. PMID:23514650

  9. [Opacification of an intraocular lens: calcification of hydrophilic intraocular lenses after gas tamponade of the anterior chamber].

    PubMed

    Schmidinger, G; Pemp, B; Werner, L

    2013-11-01

    A patient with endothelial dystrophy was treated with Descemet stripping automated endothelial keratoplasty (DSAEK) combined with cataract extraction and implantation of a hydrophilic intraocular lens (IOL, Lentis-L312, Oculentis) but visual acuity dropped from 0.15 logMAR to 0.52 logMAR 18 months later due to calcification of the IOL. With new methods of lamellar corneal transplantation being used more frequently the number of necessary anterior chamber tamponades with air/gas are increasing. In cataract cases in which a gas tamponade and transplantation might be necessary later on (cornea guttata), hydrophilic IOLs should be avoided.

  10. Fixed mydriatic pupil associated with an intraocular pressure rise as a complication of the implant of a Phakic Refractive Lens (PRL).

    PubMed

    Pérez-Cambrodí, Rafael José; Piñero-Llorens, David Pablo; Ruiz-Fortes, Juan Pedro; Blanes-Mompó, Francisco Javier; Cerviño-Expósito, Alejandro

    2014-07-01

    We describe a case report of a patient that was implanted with a posterior chamber phakic intraocular lens (Phakic Refractive Lens, PRL) for the correction of moderate myopia and who developed postoperatively a fixed mydriasis compatible with an Urrets-Zavalia Syndrome (UZS). Specifically, a sudden acute increase of IOP in the left eye was observed in the immediate postoperative period. After IOP stabilization, the refractive result was good, but a fixed and mydriatic pupil appeared. This condition led the patient to experience visual discomfort, halos, and glare associated with high levels of higher-order aberrations in spite of the good visual result. A tinted-contact lens was fitted in order to minimize those symptoms. The UZS should be considered as a possible complication after implantation of posterior chamber phakic intraocular lenses.

  11. Intraocular camera for retinal prostheses: Refractive and diffractive lens systems

    NASA Astrophysics Data System (ADS)

    Hauer, Michelle Christine

    The focus of this thesis is on the design and analysis of refractive, diffractive, and hybrid refractive/diffractive lens systems for a miniaturized camera that can be surgically implanted in the crystalline lens sac and is designed to work in conjunction with current and future generation retinal prostheses. The development of such an intraocular camera (IOC) would eliminate the need for an external head-mounted or eyeglass-mounted camera. Placing the camera inside the eye would allow subjects to use their natural eye movements for foveation (attention) instead of more cumbersome head tracking, would notably aid in personal navigation and mobility, and would also be significantly more psychologically appealing from the standpoint of personal appearances. The capability for accommodation with no moving parts or feedback control is incorporated by employing camera designs that exhibit nearly infinite depth of field. Such an ultracompact optical imaging system requires a unique combination of refractive and diffractive optical elements and relaxed system constraints derived from human psychophysics. This configuration necessitates an extremely compact, short focal-length lens system with an f-number close to unity. Initially, these constraints appear highly aggressive from an optical design perspective. However, after careful analysis of the unique imaging requirements of a camera intended to work in conjunction with the relatively low pixellation levels of a retinal microstimulator array, it becomes clear that such a design is not only feasible, but could possibly be implemented with a single lens system.

  12. Scedosporium prolificans Keratouveitis in Association with a Contact Lens Retained Intraocularly over a Long Term

    PubMed Central

    Arthur, Stella; Steed, Lisa L.; Apple, David J.; Peng, Qun; Howard, Gene; Escobar-Gomez, Marcela

    2001-01-01

    Scedosporium prolificans is a soil saprophyte that is associated with a large variety of infectious processes and with respiratory colonization in immunocompetent and immunocompromised patients. We report the first described case of S. prolificans keratouveitis associated with the intraocular long-term retention of a contact lens in a 76-year-old female patient. PMID:11724890

  13. Processes for manufacturing multifocal diffractive-refractive intraocular lenses

    NASA Astrophysics Data System (ADS)

    Iskakov, I. A.

    2017-09-01

    Manufacturing methods and design features of modern diffractive-refractive intraocular lenses are discussed. The implantation of multifocal intraocular lenses is the most optimal method of restoring the accommodative ability of the eye after removal of the natural lens. Diffractive-refractive intraocular lenses are the most widely used implantable multifocal lenses worldwide. Existing methods for manufacturing such lenses implement various design solutions to provide the best vision function after surgery. The wide variety of available diffractive-refractive intraocular lens designs reflects the demand for this method of vision correction in clinical practice and the importance of further applied research and development of new technologies for designing improved lens models.

  14. The effect of lens aging and cataract surgery on circadian rhythm.

    PubMed

    Yan, Shen-Shen; Wang, Wei

    2016-01-01

    Many organisms have evolved an approximately 24-hour circadian rhythm that allows them to achieve internal physiological homeostasis with external environment. Suprachiasmatic nucleus (SCN) is the central pacemaker of circadian rhythm, and its activity is entrained to the external light-dark cycle. The SCN controls circadian rhythm through regulating the synthesis of melatonin by pineal gland via a multisynaptic pathway. Light, especially short-wavelength blue light, is the most potent environmental time cue in circadian photoentrainment. Recently, the discovery of a novel type of retinal photoreceptors, intrinsically photosensitive retinal ganglion cells, sheds light on the mechanism of circadian photoentrainment and raises concerns about the effect of ocular diseases on circadian system. With age, light transmittance is significantly decreased due to the aging of crystalline lens, thus possibly resulting in progressive loss of circadian photoreception. In the current review, we summarize the circadian physiology, highlight the important role of light in circadian rhythm regulation, discuss about the correlation between age-related cataract and sleep disorders, and compare the effect of blue light- filtering intraocular lenses (IOLs) and ultraviolet only filtering IOLs on circadian rhythm.

  15. Laser-assisted marking for toric intraocular lens alignment.

    PubMed

    Dick, H Burkhard; Schultz, Tim

    2016-01-01

    We describe a technique of 3-dimensional spectral-domain optical coherence tomography-controlled laser-assisted corneal marking for toric intraocular lens implantation. To facilitate accurate alignment, the technique creates 2 perpendicular intrastromal incisions (width 0.75 mm) using an image-guided femtosecond laser. This was performed in a case series comprising 10 eyes of 10 patients. No posterior corneal perforation or epithelial alterations occurred. The incisions were plainly visible under the operating microscope, and no optical phenomena were reported 6 weeks after surgery. Laser-assisted marking can be performed safely and has the potential to enable precise axis marking. Dr. Dick is a paid consultant to Abbott Medical Optics, Inc. Dr. Schultz has no financial or proprietary interest in any material or method mentioned. Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  16. Intraocular lens bioactivity tested using rabbit corneal tissue cultures.

    PubMed

    Linnola, R J; Salonen, J I; Happonen, R P

    1999-11-01

    To evaluate the effects of different intraocular lens (IOL) materials on epithelial cell growth to test the sandwich theory; i.e., a bioactivity-based explanation of posterior capsule opacification (PCO) after cataract surgery. Central Hospital, Vaasa, and Institute of Dentistry and Turku Center for Biomaterials, University of Turku, Finland. Rabbit corneal tissue cultures were set up on poly(methyl methacrylate) (PMMA), heparin-surface-modified (HSM) PMMA, silicone, acrylate, and hydrogel IOLs for 1 week. The tissue consisted of intact epithelium and half the thickness of the corneal stroma, which was placed against the IOL. The growth of the epithelium was examined by light microscopy to evaluate the attachment of the corneal explant to the IOL surface. All tissue samples grew well under the culture conditions. When grown on PMMA, HSM PMMA, silicone, and hydrogel, the tissue did not attach to the IOL or the epithelium grew around the explant, suggesting that the attachment of the stroma to the IOL was poor or nonexistent. Some explants on acrylate IOLs attached directly to the IOL surface with no epithelial ingrowth between the stroma and the IOL. This tissue culture method can be used to examine the behavior of corneal tissue in contact with different IOL materials. The results suggest that the acrylate IOL may have bioactive properties. This, with the lens optic's square edge, may hinder lens epithelial cell proliferation and thus prevent PCO.

  17. Comparison of Visian toric collamer lens and toric acrylic intraocular lens implantation for the treatment of myopia with astigmatism

    PubMed Central

    Ammar, Hatem; Anbar, Mohamed; Abdellah, Marwa M

    2017-01-01

    Purpose To compare the efficacy and outcome of phakic toric implantable collamer lens (TICL) and refractive clear lens extraction with AcrySof Toric intraocular lens (TIOL) implantation for the treatment of myopic astigmatism. Patients and methods This study assessed eyes with myopic astigmatism >−1 D and ≤−4 D with a spherical equivalent >10 D or <10 D if the patients were unsuitable for corneal refractive surgery. These eyes were divided into group A, in which Visian Toric ICL™ Phakic TICL was implanted, and group B, which involved clear lens extraction with implantation of an AcrySof IQ toric SN60T3-9™ IOL. The outcome and complications were evaluated. Results This study enrolled 63 eyes of 38 patients with a follow-up period of at least 6 months. The mean postoperative spherical equivalent was −0.19±0.31 D in group A and −0.21±0.28 D in group B (P=0.69). The mean postoperative cylinder value was −0.46±0.53 D in group A and −0.32±0.41 D in group B (P=0.35). Postoperative cylinder was <1 D in 76.47% and 79.31% of eyes in groups A and B, respectively. The mean endothelial cell count was reduced by 4.32% in group A and by 5.32% in group B (P=0.003). The mean postoperative intraocular pressure increased insignificantly in group A (P=0.22) and reduced significantly in group B (P=0.004). The complication rate was 11.76% in group A and 6.90% in group B. Conclusion Both procedures showed predictable results and good visual results. However, the loss of accommodation and risk of retinal complications in the TIOL group suggest that the use of TICL for myopic astigmatism is a better choice in younger patients. PMID:28096654

  18. Energy Efficiency of a New Trifocal Intraocular Lens

    NASA Astrophysics Data System (ADS)

    Vega, F.; Alba-Bueno, F.; Millán, M. S.

    2014-01-01

    The light distribution among the far, intermediate and near foci of a new trifocal intraocular lens (IOL) is experimentally determined, as a function of the pupil size, from image analysis. The concept of focus energy efficiency is introduced because, in addition to the theoretical diffraction efficiency of the focus, it accounts for other factors that are naturally presented in the human eye such as the level of spherical aberration (SA) upon the IOL, light scattering at the diffractive steps or the depth of focus. The trifocal IOL is tested in-vitro in two eye models: the aberration-free ISO model, and a so called modified-ISO one that uses an artificial cornea with positive spherical SA in instead. The SA upon the IOL is measured with a Hartmann-Shack sensor and compared to the values of theoretical eye models. The results show, for large pupils, a notorious reduction of the energy efficiency of the far and near foci of the trifocal IOL due to two facts: the level of SA upon the IOL is larger than the value the lens is able to compensate for and there is significant light scattering at the diffractive steps. On the other hand, the energy efficiency of the intermediate focus for small pupils is enhanced by the contribution of the extended depth of focus of the near and far foci. Thus, while IOLs manufacturers tend to provide just the theoretical diffraction efficiency of the foci to show which would be the performance of the lens in terms of light distribution among the foci, our results put into evidence that this is better described by using the energy efficiency of the foci.

  19. Improved accuracy of intraocular lens power calculation with the Zeiss IOLMaster.

    PubMed

    Olsen, Thomas

    2007-02-01

    This study aimed to demonstrate how the level of accuracy in intraocular lens (IOL) power calculation can be improved with optical biometry using partial optical coherence interferometry (PCI) (Zeiss IOLMaster) and current anterior chamber depth (ACD) prediction algorithms. Intraocular lens power in 461 consecutive cataract operations was calculated using both PCI and ultrasound and the accuracy of the results of each technique were compared. To illustrate the importance of ACD prediction per se, predictions were calculated using both a recently published 5-variable method and the Haigis 2-variable method and the results compared. All calculations were optimized in retrospect to account for systematic errors, including IOL constants and other off-set errors. The average absolute IOL prediction error (observed minus expected refraction) was 0.65 dioptres with ultrasound and 0.43 D with PCI using the 5-variable ACD prediction method (p < 0.00001). The number of predictions within +/- 0.5 D, +/- 1.0 D and +/- 2.0 D of the expected outcome was 62.5%, 92.4% and 99.9% with PCI, compared with 45.5%, 77.3% and 98.4% with ultrasound, respectively (p < 0.00001). The 2-variable ACD method resulted in an average error in PCI predictions of 0.46 D, which was significantly higher than the error in the 5-variable method (p < 0.001). The accuracy of IOL power calculation can be significantly improved using calibrated axial length readings obtained with PCI and modern IOL power calculation formulas incorporating the latest generation ACD prediction algorithms.

  20. Postoperative diffuse opacification of a hydrophilic acrylic intraocular lens: analysis of an explant.

    PubMed

    Cavallini, Gian Maria; Volante, Veronica; Campi, Luca; De Maria, Michele; Fornasari, Elisa; Urso, Giancarlo

    2017-06-14

    We describe the clinicopathological and ultrastructural features of an opaque single-piece hydrophilic acrylic intraocular lens (IOL) explanted from a patient. The main outcome of this report is the documentation of calcium deposits confirmed by surface analysis. The decrease in visual acuity was due to the opacification of the IOL. The opacification involved both the optic plate and the haptics. The analysis at the scansion electron microscope revealed that the opacity was caused by the deposition of calcium and phosphate within the lens optic and haptics. This is the first case about the opacification of an Oculentis L-313. The opacification was characterized by calcium and phosphate deposition probably due to a morphological alteration of the posterior surface of the IOL.

  1. Can the circadian system of a diurnal and a nocturnal rodent entrain to ultraviolet light?

    PubMed

    Hut, R A; Scheper, A; Daan, S

    2000-01-01

    Spectral measurements of sunlight throughout the day show close correspondence between the timing of above ground activity of the European ground squirrel and the presence of ultraviolet light in the solar spectrum. However, in a standard entrainment experiment ground squirrels show no entrainment to ultraviolet light, while Syrian hamsters do entrain under the same protocol. Presented transmittance spectra for lenses, corneas, and vitreous bodies may explain the different results of the entrainment experiment. We found ultraviolet light transmittance in the colourless hamster lens (50% cut-off at 341 nm), but not in the yellow ground squirrel lens (50% cut-off around 493 nm). Ultraviolet sensitivity in the ground squirrels based upon possible fluorescence mechanisms was not evident. Possible functions of ultraviolet lens filters in diurnal mammals are discussed, and compared with nocturnal mammals and diurnal birds. Species of the latter two groups lack ultraviolet filtering properties of their lenses and their circadian system is known to respond to ultraviolet light, a feature that does not necessarily has to depend on ultraviolet photoreceptors. Although the circadian system of several species responds to ultraviolet light, we argue that the role of ultraviolet light as a natural Zeitgeber is probably limited.

  2. Adhesion of lens capsule to intraocular lenses of polymethylmethacrylate, silicone, and acrylic foldable materials: an experimental study

    PubMed Central

    Oshika, T.; Nagata, T.; Ishii, Y.

    1998-01-01

    AIMS—To investigate the adhesion characteristics of several intraocular lenses (IOLs) to the simulated and rabbit lens capsule.
METHODS—Adhesive force to bovine collagen sheets was measured in water with polymethylmethacrylate (PMMA), three piece silicone, and acrylic foldable IOLs. In rabbit eyes, phacoemulsification and IOL implantation were performed. Three weeks later, adhesion between the anterior/posterior capsules and IOL optic was tested, and the capsule was examined histologically.
RESULTS—The mean adhesive force to the collagen sheet was 1697 (SD 286) mg for acrylic foldable, 583 (49) mg for PMMA, and 0 mg for silicone IOLs (p=0.0003, Kruskal-Wallis test). Scores (0-5) of adhesion between rabbit anterior capsule and IOL optic were 4.50 (0.55) for acrylic foldable, 3.20 (0.84) for PMMA, and 0.40 (0.55) for silicone IOLs (p=0.004). Scores between rabbit posterior capsule and IOL optic displayed a similar tendency; 4.50 (0.84) for acrylic foldable, 3.00 (1.00) for PMMA, and 0.40 (0.55) for silicone IOLs (p=0.021). Histological observation indicated that the edge of IOL optic suppressed the migration of lens epithelial cells towards the centre of the posterior capsule. This inhibitory effect was most pronounced with acrylic foldable IOL and least with silicone IOL.
CONCLUSIONS—The acrylic foldable IOL adhered to the lens capsule more than the PMMA IOL, and the silicone IOL showed no adhesiveness. These differences seem to play a role in preventing lens epithelial cells from migrating and forming posterior capsule opacification.

 Keywords: intraocular lens; lens capsule; posterior capsule opacification; adhesion PMID:9713064

  3. Thin film filter lifetesting results in the extreme ultraviolet

    NASA Technical Reports Server (NTRS)

    Vedder, P. W.; Vallerga, J. V.; Gibson, J. L.; Stock, J.; Siegmund, O. H. W.

    1993-01-01

    We present the results of the thin film filter lifetesting program conducted as part of the NASA Extreme Ultraviolet Explorer (EUVE) satellite mission. This lifetesting program is designed to monitor changes in the transmission and mechanical properties of the EUVE filters over the lifetime of the mission (fabrication, assembly, launch and operation). Witness test filters were fabricated from thin film foils identical to those used in the flight filters. The witness filters have been examined and calibrated periodically over the past seven years. The filters have been examined for evidence of pinholing, mechanical degradation, and oxidation. Absolute transmissions of the flight and witness filters have been measured in the extreme ultraviolet (EUV) over six orders of magnitude at numerous wavelengths using the Berkeley EUV Calibration Facility.

  4. Foldable iris-fixated intraocular lens implantation in children.

    PubMed

    Ryan, Andrea; Hartnett, Claire; Lanigan, Bernadette; O'Keefe, Michael

    2012-09-01

      To describe the results of foldable iris-fixated intraocular lens (IOL) implantation in children.   Children with high bilateral or unilateral myopia who were intolerant of spectacle or contact lens correction were implanted with an iris-fixated foldable IOL and prospectively followed. We measured pre- and postoperative visual acuity, refraction, endothelial cell density (ECD) and National Eye Institute Visual Functioning Questionnaire-25.   Eleven eyes of six children were implanted. Indications were high bilateral myopia in children with comorbid neurobehavioural disorders, high anisometropia and high myopic astigmatism. Mean preoperative spherical equivalent (SE) refraction was -14.6 dioptres (D)±4.2 SD. Mean follow-up was 15 months. Postoperative SE refraction was -2.40 D±2.40 SD. Corrected distance visual acuity (CDVA) improved from mean logMAR 0.84±0.4 SD to postoperative 0.67±0.34 SD (p=0.005). CDVA was reduced because of coexistent ocular disorders and amblyopia. Vision-related quality of life (QOL) measures improved significantly. There were no intraoperative or postoperative serious complications.   Foldable iris-fixated IOL insertion can give a significant improvement in vision and in vision-related QOL in a subset of paediatric patients with special refractive needs who are intolerant to conventional treatment. Long-term follow-up is required for monitoring of ECD. © 2012 The Authors. Acta Ophthalmologica © 2012 Acta Ophthalmologica Scandinavica Foundation.

  5. [Laser magnetotherapy after cataract extraction with implantation of intraocular lens].

    PubMed

    Maksimov, V Iu; Zakharova, N V; Maksimova, I S; Golushkov, G A; Evseev, S Iu

    2002-01-01

    Effects of low-intensive laser and alternating magnetic field on the course of the postoperative period were studied in patients with exudative reaction after extracapsular cataract extraction with implantation of intraocular lens (IOL). The results are analyzed for 148 eyes with early exudative reaction after IOL implantation (136 patients aged 42-75 years). The patients were observed for up to 6 months. The treatment efficiency was evaluated by the clinical picture of inflammatory reaction, visual acuity, and results of biochemical analysis of the lacrimal fluid (the ratio of lipid peroxidation products to antioxidants in cell membrane). The course of the postoperative period was more benign and recovery sooner in patients of the main group in comparison with the control.

  6. Combined keratoplasty, cataract extraction, and intraocular lens implantation after corneolenticular laceration in children.

    PubMed

    Vajpayee, R B; Angra, S K; Honavar, S G

    1994-04-15

    Over a period of two years we performed combined penetrating keratoplasty, cataract extraction, and intraocular lens implantation in seven children between the ages of 2 and 12 years old. The interval between trauma and the surgery varied from six weeks to six months (3.5 +/- 1.6 months, mean +/- SD). All of the patients had undergone primary repair of corneal perforation. Fresh corneas preserved in McCarey-Kaufman medium were used. The graft size was 7.5 mm with 0.5 mm disparity. Posterior chamber polymethylmethacrylate C-loop lenses were used in all cases. The surgeon's average postkeratoplasty keratometry was used in the calculation of intraocular lens power. The follow-up period ranged from nine to 36 months (18 +/- 9.1 months, mean +/- SD). Six grafts remained clear at the final follow-up. The visual acuity ranged from 20/40 to 20/200 with final astigmatism ranging from 0.5 diopter to 2.0 diopters. One patient developed a retinal detachment 12 months after surgery, which was successfully reattached. One patient, who had preoperative corneal vascularization, had graft rejection, which was treated medically. Our limited series suggests that the triple ocular procedure is a good choice for the treatment of corneolenticular trauma in children. The proper postoperative treatment includes vigorous antiamblyopia therapy and Nd:YAG laser treatment of after-cataracts.

  7. Glue-assisted intrascleral fixation of posterior chamber intraocular lens

    PubMed Central

    Narang, Priya; Narang, Samir

    2013-01-01

    Purpose: To analyze the visual outcome of patients undergoing glue-assisted intrascleral fixation of posterior chamber intraocular lens (IOL) in the absence of posterior capsular support. Materials and Methods: This retrospective study analyzes 25 eyes which underwent IOL implantation by the glued intrascleral fixation technique. The pre and post-operative uncorrected visual acuity (UCVA), pre and post-operative best corrected visual acuity (BCVA), intraocular pressure (IOP), IOL position, anterior chamber reaction and central macular thickness were assessed and recorded. Immediate and late post-operative complications were also recorded. Results: A total of 25 eyes of 22 patients were reviewed and analyzed over a period of one year. All eyes had a foldable three-piece IOL implanted. About 84% of the eyes had a gain of one or more lines, 12% had no gain, and 4% had a fall of three lines of BCVA on Snellen's visual chart, which was attributed to cystoid macular edema (CME). Postoperatively, there was a significant improvement in the UCVA (P < 0.05) and in the BCVA (P < 0.05). Postoperative complications included decentration in one case and vitritis with chronic macular edema in another case. Optical coherence tomography (OCT) demonstrated well placed IOL with no tilt. Conclusion: Although the results of one year follow-up of glued intrascleral fixation are promising, long term studies are recommended. PMID:23685487

  8. SiC: filter for extreme ultraviolet

    NASA Astrophysics Data System (ADS)

    Mitrofanov, Alexander V.; Pudonin, Fedor A.; Zhitnik, Igor A.

    1994-09-01

    It is proposed to use thin films of silicon carbide as Extreme Ultraviolet bandpass filters transparent within 135-304 A band and with excellent cutoff blocking of the strong L(subscript (alpha) ) 1216 A line radiation. Mesh or particle track porous membrane supporting 200-800 A thickness SiC filters have been made by RF sputtering techniques. We describe the design and performance of these filters. Such type SiC filter was used in front of the microchannel plate detector of the TEREK X-Ray Telescope mounted on the Solar Observatory CORONAS-I which was successfully launched on March 2, 1994.

  9. Stabilized Alkali-Metal Ultraviolet-Band-Pass Filters

    NASA Technical Reports Server (NTRS)

    Mardesich, Nick; Fraschetti, George A.; Mccann, Timothy; Mayall, Sherwood D.; Dunn, Donald E.; Trauger, John T.

    1995-01-01

    Layers of bismuth 5 to 10 angstrom thick incorporated into alkali-metal ultraviolet-band-pass optical filters by use of advanced fabrication techniques. In new filters layer of bismuth helps to reduce surface migration of sodium. Sodium layer made more stable and decreased tendency to form pinholes by migration.

  10. Spectral transmittance of intraocular lenses under natural and artificial illumination: criteria analysis for choosing a suitable filter.

    PubMed

    Artigas, Jose M; Felipe, Adelina; Navea, Amparo; Artigas, Cristina; García-Domene, Maria C

    2011-01-01

    To compare the spectral transmission of different intraocular lenses (IOLs) with either ultraviolet (UV) or blue-light filters, and to analyze the performance of these filters with artificial light sources as well as sunlight. Experimental study. The spectral transmission curve of 10 IOLs was measured using a PerkinElmer Lambda 800 UV/VIS spectrometer (Waltham, MA). Different filtering simulations were performed using the D65 standard illuminant as daylight and standard incandescent lamp and fluorescent bulb illuminants. Spectral transmittance of the IOLs. All the IOLs studied provide good UVC (200-280 nm) and UVB (280-315 nm) protection, except for one that presented an appreciable window at 270 nm. Nevertheless, both natural and artificial sources have practically no emission under 300 nm. In the UVA (315-380 nm) range the curves of the different IOLs manifested different degrees of absorption. Not all the UV filters incorporated in different IOLs protect equally. The filters that provide greater photoprotection against UV radiation, even blue light, are yellow and orange. Then, yellow and orange IOL filters may be best suited for cases requiring special retinal protection. The filters that favor better photoreception of visible light (380-780 nm) are those that transmit this radiation close to 100%. Artificial illumination practically does not emit in the UV range, but its levels of illumination are very low when compared with solar light. A possible balance between photoprotection and photoreception could be a sharp cutoff filter with the cutoff wavelength near 400 nm and a maximum transmittance around 100%. Copyright © 2011 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  11. Surgical management of spontaneous in-the-bag intraocular lens and capsular tension ring complex dislocation.

    PubMed

    Gunenc, Uzeyir; Kocak, Nilufer; Ozturk, A Taylan; Arikan, Gul

    2014-08-01

    We describe a technique to manage late spontaneous intraocular lens (IOL) and capsular tension ring (CTR) dislocation within the intact capsular bag. The subluxated IOL and CTR complex can be positioned in a closed chamber and fixed to the pars plana at both 3 and 9 o'clock quadrants with the presented ab externo direct scleral suturation technique which provides an easy, safe and effective surgical option for such cases.

  12. Fractured Anterior Chamber Intraocular Lens (ACIOL) Complicating Nd: YAG Laser for Peripheral Iridotomy.

    PubMed

    Farah, Edgard; Koutsandrea, Chryssanthi; Papaefthimiou, Ioannis; Papaconstantinou, Dimitris; Georgalas, Ilias

    2013-01-01

    Laser peripheral iridotomy is the procedure of choice for the treatment of angle-closure glaucoma caused by relative or absolute pupillary block. Nd: YAG laser iridotomy has been reported to have several complications such as Iris bleeding, hyphema, transient IOP elevation, intraocular inflammation, choroidal, retinal detachment and vitreous hemorrhage. We report a case of a 74 year old lady on anticoagulant treatment who developed pupillary block and angle closure glaucoma after cataract surgery and anterior chamber intraocular lens (ACIOL) insertion complicated with intraoperative bleeding. The patient was treated with Nd: YAG laser iridotomy , however, the ACIOL was inadvertently fractured after a single shot of laser and it had to be replaced. Although the incidence is rare. Ophthalmologists and Opticians should be aware that an ACIOL may be fractured even after a single Nd:YAG laser shot and avoid to perform it close to the ACIOL. Pretreatment counseling should include this rare complication.

  13. Hydrophilic acrylic intraocular lens as a drug-delivery system for fourth-generation fluoroquinolones.

    PubMed

    Kleinmann, Guy; Apple, David J; Chew, Jesse; Hunter, Brian; Stevens, Scott; Larson, Scott; Mamalis, Nick; Olson, Randall J

    2006-10-01

    To evaluate the ability and safety of a hydrophilic acrylic intraocular lens (IOL) as a drug-delivery system for commercially available gatifloxacin and moxifloxacin. David J. Apple, MD, Laboratories for Ophthalmic Research, John A. Moran Eye Center, Department of Ophthalmology and Visual Sciences, University of Utah, Salt Lake City, Utah, USA. Thirty rabbits were divided into 2 similar groups. In Group A (15 rabbits, 30 eyes), hydrophilic acrylic IOLs (C-flex, Rayner Intraocular Lenses, Ltd.) presoaked for 24 hours in commercially available solutions of gatifloxacin 3 mg/mL or moxifloxacin 5 mg/mL were implanted after evacuation of the crystalline lens. Group B (15 rabbits, 30 eyes) had topical preoperative and postoperative cataract prophylaxis with gatifloxacin 3 mg/mL or moxifloxacin 5 mg/mL; IOLs that were not presoaked were also implanted after evacuation of the crystalline lenses. In both groups, aqueous humor samples were taken 4, 8, or 12 hours after IOL implantation (5 eyes at each time point) to determine the antibiotic concentrations. Clinical examinations were performed 24 hours postoperatively. The antibiotic concentrations in Group A (presoaked IOLs) were statistically significantly higher than those in Group B (topical) for both antibiotics in all postoperative samples except moxifloxacin at 12 hours. In both groups, there was no statistically significant difference between the concentrations of the 2 antibiotics. No eye showed signs of clinical toxicity. Results show the C-flex IOL is a safe and effective drug-delivery system for fourth-generation fluoroquinolones.

  14. Filtering and polychromatic vision in mantis shrimps: themes in visible and ultraviolet vision.

    PubMed

    Cronin, Thomas W; Bok, Michael J; Marshall, N Justin; Caldwell, Roy L

    2014-01-01

    Stomatopod crustaceans have the most complex and diverse assortment of retinal photoreceptors of any animals, with 16 functional classes. The receptor classes are subdivided into sets responsible for ultraviolet vision, spatial vision, colour vision and polarization vision. Many of these receptor classes are spectrally tuned by filtering pigments located in photoreceptors or overlying optical elements. At visible wavelengths, carotenoproteins or similar substances are packed into vesicles used either as serial, intrarhabdomal filters or lateral filters. A single retina may contain a diversity of these filtering pigments paired with specific photoreceptors, and the pigments used vary between and within species both taxonomically and ecologically. Ultraviolet-filtering pigments in the crystalline cones serve to tune ultraviolet vision in these animals as well, and some ultraviolet receptors themselves act as birefringent filters to enable circular polarization vision. Stomatopods have reached an evolutionary extreme in their use of filter mechanisms to tune photoreception to habitat and behaviour, allowing them to extend the spectral range of their vision both deeper into the ultraviolet and further into the red.

  15. Pigment dispersion and Artisan phakic intraocular lenses: crystalline lens rise as a safety criterion.

    PubMed

    Baïkoff, Georges; Bourgeon, Grégoire; Jodai, Horacio Jitsuo; Fontaine, Aline; Lellis, Fernando Viera; Trinquet, Laure

    2005-04-01

    To validate the theory that crystalline lens rise can be used as a safety criterion to prevent pigment dispersion in eyes with an Artisan phakic intraocular lens (IOL) (Ophtec BV). Monticelli Clinic, Marseilles, France. A comparative analysis of crystalline lens rise in 9 eyes with pigment dispersion and 78 eyes without dispersion was performed. All eyes had previous implantation of an Artisan IOL. Anterior segment imaging was done using an anterior chamber optical coherence tomography (AC OCT) prototype. Crystalline lens rise was defined by the distance between the anterior pole of the crystalline lens and the horizontal plane joining the opposite iridocorneal recesses. The study confirmed that crystalline lens rise can be considered a safety criterion for implantation of Artisan-type phakic IOLs. The higher the crystalline lens rise, the greater the risk for developing pigment dispersion in the area of the pupil. This complication occurred more frequently in hyperopic eyes than in myopic eyes. Results indicate there is little or no risk for pigment dispersion if the rise is less than 600 microm; 67% of eyes with a rise of 600 microm or more developed pupillary pigment dispersion. In some cases in which the IOL was loosely fixated, there was no traction on the iris root and dispersion was prevented or delayed. Crystalline lens rise should be considered a new safety criterion for Artisan phakic IOL implantation and should also be applied to other types of phakic IOLs. The distance remaining between the crystalline lens rise and a 600 microm theoretical safety level allows one to calculate how long the IOL can safely remain in the eye.

  16. The effect of lens aging and cataract surgery on circadian rhythm

    PubMed Central

    Yan, Shen-Shen; Wang, Wei

    2016-01-01

    Many organisms have evolved an approximately 24-hour circadian rhythm that allows them to achieve internal physiological homeostasis with external environment. Suprachiasmatic nucleus (SCN) is the central pacemaker of circadian rhythm, and its activity is entrained to the external light-dark cycle. The SCN controls circadian rhythm through regulating the synthesis of melatonin by pineal gland via a multisynaptic pathway. Light, especially short-wavelength blue light, is the most potent environmental time cue in circadian photoentrainment. Recently, the discovery of a novel type of retinal photoreceptors, intrinsically photosensitive retinal ganglion cells, sheds light on the mechanism of circadian photoentrainment and raises concerns about the effect of ocular diseases on circadian system. With age, light transmittance is significantly decreased due to the aging of crystalline lens, thus possibly resulting in progressive loss of circadian photoreception. In the current review, we summarize the circadian physiology, highlight the important role of light in circadian rhythm regulation, discuss about the correlation between age-related cataract and sleep disorders, and compare the effect of blue light- filtering intraocular lenses (IOLs) and ultraviolet only filtering IOLs on circadian rhythm. PMID:27500118

  17. Ultra-widefield retinal imaging through a black intraocular lens.

    PubMed

    Yusuf, Imran H; Fung, Timothy H M; Patel, Chetan K

    2015-09-01

    To evaluate the feasibility of ultra-widefield retinal imaging in patients with near infrared (IR)-transmitting black intraocular lenses (IOLs). Oxford Eye Hospital, Oxford, United Kingdom. Laboratory evaluation of a diagnostic technology with interventional case report. The field of retinal imaging through a Morcher poly(methyl methacrylate) (PMMA) black IOL was determined in a purpose-built adult schematic model eye with the HRA2 Spectralis confocal scanning laser ophthalmoscope using standard imaging, Staurenghi retina lens-assisted imaging, and ultra-widefield noncontact imaging. Retinal imaging using each modality was then performed on a patient implanted with another Morcher PMMA black IOL model. Ultra-widefield noncontact imaging and lens-assisted imaging captured up to 150 degrees of field (versus 40 degrees with a standard confocal scanning laser ophthalmoscope). Ultra-widefield retinal images were successfully acquired in a patient eye with a black IOL. This study has identified the first ultra-widefield retinal imaging modalities for patients with near IR-transmitting black IOLs. Should larger studies confirm this finding, noncontact ultra-widefield confocal scanning laser ophthalmoscopy might be considered the gold standard imaging technique for retinal surveillance in patients with near IR-transmitting black IOLs. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  18. Injectable suture device for intraocular lens fixation.

    PubMed

    Smith, Jesse M; Erlanger, Michael; Olson, Jeffrey L

    2015-12-01

    We describe a surgical technique for scleral fixation of a posterior chamber intraocular lens (PC IOL) using a 24-gauge injectable polypropylene suture delivery system. A 3-piece PC IOL is inserted into the anterior chamber of the eye. Two sclerotomies are made 1.5 mm posterior to the limbus using a microvitreoretinal blade. The 24-gauge injector delivers a preformed suture loop into the eye with the double-armed needles still external to the eye. Each polypropylene IOL haptic is directed through the loop using microforceps. The suture loop is tightened around the haptic, and the attached needles are used to fixate the IOL to the sclera and close the sclerotomies simultaneously. This technique has been used in an ex vivo porcine eye and in an aphakic patient. In the latter, the IOL was quickly fixated to the sclera and maintained a stable position postoperatively. Dr. Olson has a patent pending for the device described in this article. No other author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  19. Treatment of dystrophic calcification on a silicone intraocular lens with pars plana vitrectomy

    PubMed Central

    Mehta, Nitish; Goldberg, Roger A; Shah, Chirag P

    2014-01-01

    Purpose Dense, vision-obscuring calcification on the posterior aspect of silicone intraocular lenses (IOLs) is often not amenable to neodymium:yttrium-aluminum-garnet capsulotomy, and, in prior reports, has required IOL exchange. We report the successful removal of dense calcium deposition on the posterior surface of a three-piece silicone lens using pars plana vitrectomy (PPV). Materials and methods A 23-gauge PPV was performed using the Stellaris® vitrectomy system. A light pipe was used to retroilluminate the IOL, and a dense fibrous tissue setting with a low cut-rate and high aspiration rate was able to clear the visual axis of the dystrophic calcification without damaging the IOL optic. Results Visual acuity improved from 20/100 to 20/25. Conclusion Small-gauge PPV may be utilized to remove dense dystrophic calcium deposits on the lens surface in lieu of IOL exchange. PMID:25045246

  20. Professor Peter Choyce: an early pioneer of intraocular lenses and corneal/refractive surgery.

    PubMed

    Pandey, Suresh K; Apple, David J

    2005-06-01

    Professor Peter Choyce, FRCS, DOMS, MS, was one of the pioneers of intraocular lens implant surgery. He developed an interest in artificial lens implantation following cataract surgery, a procedure that was widely criticized by the ophthalmic establishment in the UK, Europe, North America and other countries. Owing to the opposition to the intraocular lenses, Peter Choyce together with Sir Harold Ridley co-founded the International Intraocular Implant Club in 1966, which was responsible for the gradual acceptance of artificial lens implantation. Peter Choyce developed several models of intraocular lens, but did not patent the majority of them. The Choyce Mark IX, manufactured by Rayner Intraocular Lenses, became the first US Food and Drug Administration-approved intraocular lens in 1981. A review of Peter Choyce's record confirms a significant number of original innovations in the field of anterior segment surgery, including many procedures taken for granted today, but not associated with his name. These include early work on both kerato- and intraocular lens-refractive procedures, keratoprosthesis, pioneering paediatric implant procedures and others. Unfortunately his tenacious adherence to anterior chamber lens technology, while in general clinically sound, caused many to question his influence and hence he remained poorly understood even until after his death. He passed away on 8 August 2001 after a long fight with colon cancer. In this article, we provide evidence and elaborate Peter Choyce's accomplishments, which places him as one of the most innovative ophthalmologist in his surgical field in the twentieth century.

  1. Does infrared or ultraviolet light damage the lens?

    PubMed Central

    Söderberg, P G; Talebizadeh, N; Yu, Z; Galichanin, K

    2016-01-01

    In daylight, the human eye is exposed to long wavelength ultraviolet radiation (UVR), visible radiation and short wavelength infrared radiation (IRR). Almost all the UVR and a fraction of the IRR waveband, respectively, left over after attenuation in the cornea, is absorbed in the lens. The time delay between exposure and onset of biological response in the lens varies from immediate-to-short-to-late. After exposure to sunlight or artificial sources, generating irradiances of the same order of magnitude or slightly higher, biological damage may occur photochemically or thermally. Epidemiological studies suggest a dose-dependent association between short wavelength UVR and cortical cataract. Experimental data infer that repeated daily in vivo exposures to short wavelength UVR generate photochemically induced damage in the lens, and that short delay onset cataract after UVR exposure is photochemically induced. Epidemiology suggests that daily high-intensity short wavelength IRR exposure of workers, is associated with a higher prevalence of age-related cataract. It cannot be excluded that this effect is owing to a thermally induced higher denaturation rate. Recent experimental data rule out a photochemical effect of 1090 nm in the lens but other wavelengths in the near IRR should be investigated. PMID:26768915

  2. Using continuous intraoperative optical coherence tomography measurements of the aphakic eye for intraocular lens power calculation.

    PubMed

    Hirnschall, Nino; Norrby, Sverker; Weber, Maria; Maedel, Sophie; Amir-Asgari, Sahand; Findl, Oliver

    2015-01-01

    To include intraoperative measurements of the anterior lens capsule of the aphakic eye into the intraocular lens power calculation (IPC) process and to compare the refractive outcome with conventional IPC formulae. In this prospective study, a prototype operating microscope with an integrated continuous optical coherence tomography (OCT) device (Visante attached to OPMI VISU 200, Carl Zeiss Meditec AG, Germany) was used to measure the anterior lens capsule position after implanting a capsular tension ring (CTR). Optical biometry (intraocular lens (IOL) Master 500) and ACMaster measurements (Carl Zeiss Meditec AG, Germany) were performed before surgery. Autorefraction and subjective refraction were performed 3 months after surgery. Conventional IPC formulae were compared with a new intraoperatively measured anterior chamber depth (ACD) (ACDIntraOP) partial least squares regression (PLSR) model for prediction of the postoperative refractive outcome. In total, 70 eyes of 70 patients were included. Mean axial eye length (AL) was 23.3 mm (range: 20.6-29.5 mm). Predictive power of the intraoperative measurements was found to be slightly better compared to conventional IOL power calculations. Refractive error dependency on AL for Holladay I, HofferQ, SRK/T, Haigis and ACDintraOP PLSR was r(2)=-0.42 (p<0.0001), r(2)=-0.5 (p<0.0001), r(2)=-0.34 (p=0.010), r(2)=-0.28 (p=0.049) and r(2)<0.001 (p=0.866), respectively, ACDIntraOP measurements help to better predict the refractive outcome and could be useful, if implemented in fourth-generation IPC formulae. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  3. Reverse pupillary block associated with pigment dispersion syndrome after in-the-bag intraocular lens implantation.

    PubMed

    Itagaki, Hideo; Kunikata, Toshio; Hiratsuka, Kentaro; Saito, Junichiro; Oshika, Tetsuro

    2013-12-01

    A 61-year-old man with high myopia who had received a systemic α1A-adrenoceptor antagonist had phacoemulsification and in-the-bag intraocular lens implantation in the right eye. One day postoperatively, marked pigment dispersion in the anterior chamber, posterior bowing of the iris, and iridodonesis were noted associated with a subsequent elevation in intraocular pressure (IOP). Pharmacological pupil dilation was effective in reducing pigment dispersion and IOP, and laser peripheral iridotomy was performed to alleviate posterior bowing of the iris. We hypothesize that dynamic changes in the aqueous humor flow by cataract surgery and latent flaccidity of the iris due to the systemic α1A-adrenoceptor antagonist caused reverse pupillary block. High myopia may be another risk factor for this complication. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  4. A comparison of two different formulations of diclofenac sodium 0.1% in the treatment of inflammation following cataract-intraocular lens surgery.

    PubMed

    Mester, Ulrich; Lohmann, Chris; Pleyer, U; Steinkamp, G; Völcker, E; Kruger, H; Raj, Palaniswamy Sunder

    2002-01-01

    To compare the efficacy, tolerability and local tolerance of diclofenac sodium 0.1% containing hydroxypropylgamma cyclodextrin preserved with benzalkonium chloride 0.005% (Voltaren Ophtha CD), with that of diclofenac sodium 0.1% preserved with thiomersal 0.004% (Voltaren Ophtha) in the treatment of inflammation after cataract-intraocular lens surgery. Randomised 2:1, double-masked, parallel-group study in six centres in Germany. 299 patients scheduled to undergo phacoemulsification with posterior chamber intraocular lens implantation. Study medications were instilled four times in the 30 minutes before surgery and four times daily from the first postoperative day. The key efficacy variable was the reduction in anterior chamber flare (photons/millisecond) from day 1 to day 6 to 8. Patients underwent comprehensive ocular examinations, including laser flaremetry (KOWA), preoperatively and postoperatively at days 1, 6 to 8 and 24 to 32. 268 patients (Voltaren Ophtha CD 177, Voltaren Ophtha 91) completed the day 6 to 8 visit without any protocol violations. Reduction in the degree of intraocular inflammation with Voltaren Ophtha CD was equivalent to that achieved with Voltaren Ophtha at the day 6 to 8 [95% confidence interval (CI) -3.07 to +0.54] and day 24 to 32 (95% CI -1.44 to +1.40) visits. Although there was no significant (p = 0.464) difference between the two study groups in patients' global assessment of local tolerance at day 24 to 32, ocular discomfort was significantly (p = 0.023) less with Voltaren Ophtha CD compared with Voltaren Ophtha. Voltaren Ophtha CD was as effective and well tolerated but had less ocular discomfort compared with Voltaren Ophtha in the treatment of ocular inflammation after phacoemulsification with intraocular lens implantation. This new formulation of diclofenac sodium 0.1% may be used as an alternative to the existing formulations of ophthalmic diclofenac sodium 0.1%.

  5. Validity of automated refraction after segmented refractive multifocal intraocular lens implantation.

    PubMed

    Albarrán-Diego, César; Muñoz, Gonzalo; Rohrweck, Stephanie; García-Lázaro, Santiago; Albero, José Ricardo

    2017-01-01

    To evaluate the clinical utility of automated refraction (AR) and keratometry (KR) compared with subjective or manifest refraction (MR) after cataract or refractive lens exchange surgery with implantation of Lentis Mplus X (Oculentis GmbH) refractive multifocal intraocular lens (IOL). Eighty-six eyes implanted with the Lentis Mplus X multifocal IOL were included. MR was performed in all patients followed by three consecutive AR measurements using the Topcon KR-8000 autorefractor. Assessment of repeatability of consecutive AR before and after dilation with phenylephrine 10%, and comparison of the AR and KR with MR using vector analysis were performed at 3mo follow-up. Analysis showed excellent repeatability of the AR measurements. Linear regression of AR versus MR showed good correlation for sphere and spherical equivalent, whereas the correlation for astigmatism was low. The mean difference AR-MR was -1.28±0.29 diopters (D) for sphere. Astigmatism showed better correlation between KR and MR. We suggest AR sphere plus 1.25 D and the KR cylinder as the starting point for MR in eyes with a Lentis Mplus X multifocal IOL. If AR measurements are equal to MR, decentration of the IOL should be suspected.

  6. Intraocular Lens Opacification After Endothelial Keratoplasty as Analyzed by Environmental Scanning Electron Microscopy.

    PubMed

    Verdaguer, Paula; Gris, Oscar; Casaroli-Marano, Ricardo P; Elies, Daniel; Muñoz-Gutierrez, Gerardo; Güell, Jose L

    2015-08-01

    To describe a case of hydrophilic intraocular lens (IOL) opacification based on IOL analysis after Descemet stripping automated endothelial keratoplasty. A 60-year-old woman had uneventful phacoemulsification after the implantation of a hydrophilic IOL (Akreos-Adapt; Bausch & Lomb) into both eyes. Because of postoperative corneal decompensation in the right eye, 2 Descemet stripping automated endothelial keratoplasty operations were performed within 1 year. After the second procedure, the graft was not well attached, requiring an intracameral injection of air on day 3. After 1 year, opacification was observed on the superior 2/3 of the anterior surface of the IOL, along with a significant decrease in visual acuity. The IOL was explanted 6 months after the opacification. Environmental scanning electron microscopy followed by x-ray microanalysis revealed an organic biofilm on the surface of the IOL. To our knowledge, this is the first reported case in which the material deposited on the lens is organic rather than calcific.

  7. Femtosecond laser–assisted cataract surgery in vitrectomized eye with posterior chamber phakic intraocular lens

    PubMed Central

    Anisimova, Natalia; Malyugin, Boris; Arbisser, Lisa B.; Sobolev, Nikolay

    2017-01-01

    Summary We describe a case of femtosecond laser–assisted cataract surgery (FLACS) in an eye with multiple comorbidities, including retinal detachment surgery, high myopia, posterior chamber phakic intraocular lens (PC pIOL) and residual, emulsified, silicone oil located in the anterior chamber. FLACS was affected by the optical blockage, but the incomplete capsular tear was recoverable. The case suggests that silicone oil bubbles concentrated at the dome of the posterior corneal surface, along with the PC pIOL optic edges and scars after corneal astigmatic relaxing incisions can lead to incomplete anterior capsulotomy. PMID:28924422

  8. Evaluating the Biostability of Yellow and Clear Intraocular Lenses with a System Simulating Natural Intraocular Environment

    PubMed Central

    Hayashi, Rijo; Hayashi, Shimmin; Arai, Kiyomi; Yoshida, Shinichirou; Chikuda, Makoto; Machida, Shigeki

    2016-01-01

    Purpose Blue light–filtering intraocular lenses (IOLs) are thought to protect the retina from blue light damage after cataract surgery, and the implantation of yellow-tinted IOLs has been commonly used in cataract surgery. To our knowledge, this is the first investigation measuring the long-term biostability of yellow-tinted IOLs using an in vitro system simulating natural intraocular environment. Methods Six hydrophobic acrylic IOLs, three clear IOLs, and three yellow-tinted IOLs were included in the study. Each yellow-tinted IOL was a matching counterpart of a clear IOL, with the only difference being the lens color. The IOLs were kept in conditions replicating the intraocular environment using a perfusion culture system for 7 months. Resolution, light transmittance rate, and the modulation transfer function (MTF) were measured before and after culturing. Surface roughness of the anterior and posterior surfaces was also measured. Results After culturing for 7 months, there were no changes in the resolution, the light transmittance rate, and MTF. The surface roughness of the anterior and posterior surfaces increased after culturing; however, this increase was clinically insignificant. There were no differences in surface roughness between the clear and yellow-tinted IOLs, either before or after culturing. Conclusions A novel in vitro system replicating intraocular environment was used to investigate the biostability of yellow-tinted IOLs. The surface roughness showed no clinically significant increase after culturing for 7 months. Translational Relevance This system is useful for evaluating the biostability of IOLs. PMID:27933221

  9. Hydrophilic acrylic intraocular lens optic and haptics opacification in a diabetic patient: bilateral case report and clinicopathologic correlation.

    PubMed

    Pandey, Suresh K; Werner, Liliana; Apple, David J; Kaskaloglu, Mahmut

    2002-11-01

    To report clinicopathologic and ultrastructural features of two opacified single-piece hydrophilic acrylic intraocular lenses (IOLs) explanted from a diabetic patient. Interventional case report with clinicopathologic correlation. A 64-year-old white female underwent phacoemulsification and implantation of a single-piece hydrophilic acrylic lens (SC60B-OUV; Medical Developmental Research, Inc., Clear Water, FL) in October 1998 in the left eye and in July 1999 in the right eye. The best-corrected visual acuity after surgery was 20/60 in the left eye and 20/50 in the right eye. The patient had a marked decrease in visual acuity in June 2000 as a result of a milky, white opalescence of both lenses. Intraocular lens explantation and exchange was performed in both eyes and the explanted IOLs were submitted to our center for detailed pathologic, histochemical, and ultrastructural evaluation. They were stained with alizarin red and the von Kossa method for calcium, and also underwent scanning electron microscopy and energy dispersive radiograph spectroscopy to ascertain the nature of the deposits leading to opacification. Documentation of calcium deposits confirmed by histochemical stains and surface analyses. Opacification of the IOL was found to be the cause of decreased visual acuity. The opacification involved both the IOL optic and the haptics in the left eye and was confined to the IOL optic in the right eye. Histochemical and ultrastructural analyses revealed that the opacity was caused by deposition of calcium and phosphate within the lens optic and haptics. There are two features that distinguish this case from those reported earlier. This is the first clinicopathologic report of lens opacification that has involved completely the lens optic and the haptics. Second, these two explanted IOLs document the first bilateral case. This process of intraoptic and haptic opacification represents dystrophic calcification of unknown cause. Diabetic patients appear to be

  10. Characteristics and performance of a two-lens slit spatial filter for high power lasers

    NASA Astrophysics Data System (ADS)

    Xiong, Han; Gao, Fan; Zhang, Xiang; Zhuang, Zhenwu; Zhao, Jianjun; Yuan, Xiao

    2017-05-01

    The characteristics of a two-lens slit spatial filtering system on image relay and spatial filtering are discussed with detailed theoretical calculation and numerical simulation. The slit spatial filter can be used as the cavity spatial filter in large laser systems, such as National Ignition Facility, which can significantly decrease the focal intensity in cavity spatial filter and suppress or even avoid the pinhole (slit) closure while keeping the output power and beam quality. Additionally, the overall length of the cavity spatial filter can be greatly reduced with the use of the two-lens slit spatial filter.

  11. Capsular Outcomes After Pediatric Cataract Surgery Without Intraocular Lens Implantation

    PubMed Central

    Tan, Xuhua; Lin, Haotian; Lin, Zhuoling; Chen, Jingjing; Tang, Xiangchen; Luo, Lixia; Chen, Weirong; Liu, Yizhi

    2016-01-01

    Abstract The objective of this study was to investigate capsular outcomes 12 months after pediatric cataract surgery without intraocular lens implantation via qualitative classification and quantitative measurement. This study is a cross-sectional study that was approved by the institutional review board of Zhongshan Ophthalmic Center of Sun Yat-sen University in Guangzhou, China. Digital coaxial retro-illumination photographs of 329 aphakic pediatric eyes were obtained 12 months after pediatric cataract surgery without intraocular lens implantation. Capsule digital coaxial retro-illumination photographs were divided as follows: anterior capsule opening area (ACOA), posterior capsule opening area (PCOA), and posterior capsule opening opacity (PCOO). Capsular outcomes were qualitatively classified into 3 types based on the PCOO: Type I—capsule with mild opacification but no invasion into the capsule opening; Type II—capsule with moderate opacification accompanied by contraction of the ACOA and invasion to the occluding part of the PCOA; and Type III—capsule with severe opacification accompanied by total occlusion of the PCOA. Software was developed to quantitatively measure the ACOA, PCOA, and PCOO using standardized DCRPs. The relationships between the accurate intraoperative anterior and posterior capsulorhexis sizes and the qualitative capsular types were statistically analyzed. The DCRPs of 315 aphakic eyes (95.8%) of 191 children were included. Capsular outcomes were classified into 3 types: Type I—120 eyes (38.1%); Type II—157 eyes (49.8%); Type III—38 eyes (12.1%). The scores of the capsular outcomes were negatively correlated with intraoperative anterior capsulorhexis size (R = −0.572, P < 0.001), but no significant correlation with intraoperative posterior capsulorhexis size (R = −0.16, P = 0.122) was observed. The ACOA significantly decreased from Type I to Type II to Type III, the PCOA increased in size from Type I to Type

  12. Combined ab interno trabeculotomy and lens extraction: a novel management option for combined uveitic and chronic narrow angle raised intraocular pressure

    PubMed Central

    Lin, Siying; Gupta, Bhaskar; Rossiter, Jonathan

    2016-01-01

    Minimally invasive glaucoma surgery is a developing area that has the potential to replace traditional glaucoma surgery, with its known risk profile, but at present there are no randomised controlled data to validate its use. We report on a case where sequential bilateral combined ab interno trabeculotomy and lens extraction surgery was performed on a 45-year-old woman with combined uveitic and chronic narrow angle raised intraocular pressure. Maximal medical management alone could not control the intraocular pressure. At 12-month follow-up, the patient had achieved stable intraocular pressure in both eyes on a combination of topical ocular antiglaucomatous and steroid therapies. This case demonstrates the effectiveness of trabecular meshwork ablation via ab interno trabeculotomy in a case of complex mixed mechanism glaucoma. PMID:26833953

  13. Spherotoric bag-in-the-lens intraocular lens: power calculation and predictive misalignment nomogram.

    PubMed

    Gobin, Laure; Tassignon, Marie-José; Mathysen, Danny

    2011-06-01

    To propose a method of calculating the power of the 1-sided posterior chamber toric bag-in-the-lens (BIL) intraocular lens (IOL) and propose a misalignment nomogram to calculate the postoperative rotational misalignment or predict the effect of preoperative existing irregular corneal astigmatism. Antwerp University Hospital, Department of Ophthalmology, Antwerp, Belgium. Cohort study. The new IOL calculation formula uses the steepest corneal meridian and flattest corneal meridian separately (regular spherical IOL formula) followed by a customized A-constant approach based on the changes in the IOL principal plane depending on the spherical and cylindrical powers (thickness) of the IOL. The calculation of the remaining astigmatism (power and axis) in cases of postoperative rotational misalignment resulted in a nomogram that can also be used to predict the degree of tolerance for irregular corneal astigmatism correction at the lenticular plane. The calculation is performed using a worksheet. Because 10 degrees of misalignment would result in 35% refractive inaccuracy, it is the maximum acceptable corneal astigmatic irregularity for correction at the lenticular plane. Calculation of spherocylindrical power is specific to each toric IOL. Because the surgeon must fully understand the optical properties of the toric IOL that is going to be implanted, a comprehensive outline of a new calculation method specific to the toric BIL IOL is proposed. Primary rotational misalignment of the toric BIL IOL can be fine tuned postoperatively. Drs. Gobin and Mathysen have no financial or proprietary interest in any material or method mentioned. Additional disclosures are found in the footnotes. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  14. Comparison between bilateral implantation of a trifocal intraocular lens and blended implantation of two bifocal intraocular lenses

    PubMed Central

    Vilar, César; Hida, Wilson Takashi; de Medeiros, André Lins; Magalhães, Klayny Rafaella Pereira; de Moraes Tzelikis, Patrick Frensel; Chaves, Mario Augusto Pereira Dias; Motta, Antônio Francisco Pimenta; Carricondo, Pedro Carlos; Alves, Milton Ruiz; Nosé, Walton

    2017-01-01

    Purpose To compare visual outcomes and performance between bilateral implantation of a diffractive trifocal intraocular lens (IOL) Acrysof®PanOptix® TFNT00 and blended implantation of two different near add power bifocal IOLs: Acrysof® Restor® SV25T0 in dominant eye and Acrysof® Restor® SN6AD1 in the nondominant eye. Methods This prospective, nonrandomized, consecutive and comparative study assessed 20 patients (40 eyes) who had bilateral cataract surgery performed using the IOLs described. Patients were divided into groups, bilateral trifocal implant and blended implant. Evaluation included measurement of binocular uncorrected and corrected distance visual acuity at 4 m (UDVA, CDVA) and uncorrected intermediate (60 cm) and near (at 40 cm) visual acuity; contrast sensitivity (CS) and visual defocus curve. Results Postoperative CDVA comparison showed no statistical significance between groups. UDVA was significantly better in the trifocal groups. Under photopic conditions, the trifocal group had better CS in higher frequencies with and without glare. The binocular defocus curve demonstrated a trifocal behavior in both groups, with the bilateral trifocal group exhibiting better performance for intermediate vision. Conclusion Both lens combinations were able to provide good near, intermediate and distance vision, with the trifocal group showing significantly better performance at intermediate distances and better CS under photopic conditions. PMID:28814826

  15. Validity of automated refraction after segmented refractive multifocal intraocular lens implantation

    PubMed Central

    Albarrán-Diego, César; Muñoz, Gonzalo; Rohrweck, Stephanie; García-Lázaro, Santiago; Albero, José Ricardo

    2017-01-01

    AIM To evaluate the clinical utility of automated refraction (AR) and keratometry (KR) compared with subjective or manifest refraction (MR) after cataract or refractive lens exchange surgery with implantation of Lentis Mplus X (Oculentis GmbH) refractive multifocal intraocular lens (IOL). METHODS Eighty-six eyes implanted with the Lentis Mplus X multifocal IOL were included. MR was performed in all patients followed by three consecutive AR measurements using the Topcon KR-8000 autorefractor. Assessment of repeatability of consecutive AR before and after dilation with phenylephrine 10%, and comparison of the AR and KR with MR using vector analysis were performed at 3mo follow-up. RESULTS Analysis showed excellent repeatability of the AR measurements. Linear regression of AR versus MR showed good correlation for sphere and spherical equivalent, whereas the correlation for astigmatism was low. The mean difference AR-MR was -1.28±0.29 diopters (D) for sphere. Astigmatism showed better correlation between KR and MR. CONCLUSION We suggest AR sphere plus 1.25 D and the KR cylinder as the starting point for MR in eyes with a Lentis Mplus X multifocal IOL. If AR measurements are equal to MR, decentration of the IOL should be suspected. PMID:29181318

  16. Broadband ultraviolet reflectance filters for space applications.

    NASA Technical Reports Server (NTRS)

    Osantowski, J. F.; Toft, A. R.

    1973-01-01

    It is shown that a simple metal-dielectric-metal filter for broadband ultraviolet (BUV) reflectance control can provide a stable and effective means for reducing stray visible radiation in UV reflective optical systems. The application of such a filter in a BUV instrument resulted in a reduction of scattered visible light by at least an order of magnitude. The instrument has been in orbit for 2.5 year without loss of sensitivity or an increase in scattered light background.-

  17. Intraocular lens design for treating high myopia based on individual eye model

    NASA Astrophysics Data System (ADS)

    Wang, Yang; Wang, Zhaoqi; Wang, Yan; Zuo, Tong

    2007-02-01

    In this research, we firstly design the phakic intraocular lens (PIOL) based on individual eye model with optical design software ZEMAX. The individual PIOL is designed to correct the defocus and astigmatism, and then we compare the PIOL power calculated from the individual eye model with that from the experiential formula. Close values of PIOL power are obtained between the individual eye model and the formula, but the suggested method has more accuracy with more functions. The impact of PIOL decentration on human eye is evaluated, including rotation decentration, flat axis decentration, steep axis decentration and axial movement of PIOL, which is impossible with traditional method. To control the PIOL decentration errors, we give the limit values of PIOL decentration for the specific eye in this study.

  18. Preliminary study of a new intraocular method in the diagnosis and treatment of Propionibacterium acnes endophthalmitis following cataract extraction.

    PubMed

    Owens, S L; Lam, S; Tessler, H H; Deutsch, T A

    1993-04-01

    Late endophthalmitis, due to Propionibacterium acnes, developed in three patients following uncomplicated extracapsular cataract extraction and posterior chamber intraocular lens (PC-IOL) insertion. Cultures from the capsular bag yielded P. acnes in all three. With topical anesthesia and through an anterior chamber paracentesis, culture specimens were taken from and clindamycin irrigated into the capsular bag. Filtered 100% oxygen was introduced into the anterior chamber in two; the third also received an injection of gentamicin and dexamethasone into the capsular bag. After treatment, two patients received oral antibiotics; one received hyperbaric oxygen therapy. Visual acuity was improved and inflammation reduced in all three. However, after treatment, ocular toxic effects due to clindamycin were suspected in one. This approach offers several clear advantages, including topical anesthesia, outpatient management, elimination of the need for vitrectomy, and retention of the intraocular lens (IOL).

  19. Assessment of subjective intraocular forward scattering and quality of vision after posterior chamber phakic intraocular lens with a central hole (Hole ICL) implantation.

    PubMed

    Iijima, Ayaka; Shimizu, Kimiya; Yamagishi, Mayumi; Kobashi, Hidenaga; Igarashi, Akihito; Kamiya, Kazutaka

    2016-12-01

    To evaluate the subjective intraocular forward scattering and quality of vision after posterior chamber phakic intraocular lens with a central hole (Hole ICL, STAAR Surgical) implantation. We prospectively examined 29 eyes of 29 consecutive patients (15 men and 14 women; ages, 37.2 ± 8.8 years) undergoing Hole ICL implantation. We assessed the values of the logarithmic straylight value [log (s)] using a straylight meter (C-Quant ™ , Oculus) preoperatively and 3 months postoperatively. The patients completed a questionnaire detailing symptoms on a quantitative grading scale (National Eye Institute Refractive Error Quality of Life Instrument-42; NEI RQL-42) 3 months postoperatively. We compared the preoperative and postoperative values of the log(s) and evaluated the correlation of these values with patient subjective symptoms. The mean log(s) was not significantly changed, from 1.07 ± 0.20 preoperatively, to 1.06 ± 0.17 postoperatively (Wilcoxon signed-rank test, p = 0.641). There was a significant correlation between the preoperative and postoperative log(s) (Spearman's correlation coefficient r = 0.695, p < 0.001). The postoperative log(s) was significantly associated with the scores of glare in the questionnaire (Spearman's correlation coefficient r = -0.575, p = 0.017). According to our experience, Hole ICL implantation does not induce a significant additional change in the subjective intraocular forward scattering. The symptom of glare after Hole ICL implantation was significantly correlated with the postoperative intraocular forward scattering in relation to the preoperative one. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  20. Intraocular Lens Fragmentation Using Femtosecond Laser: An In Vitro Study

    PubMed Central

    Bala, Chandra; Shi, Jeffrey; Meades, Kerrie

    2015-01-01

    Purpose: To transect intraocular lenses (IOLs) using a femtosecond laser in cadaveric human eyes. To determine the optimal in vitro settings, to detect and characterize gasses or particles generated during this process. Methods: A femtosecond laser was used to transect hydrophobic and hydrophilic acrylic lenses. The settings required to enable easy separation of the lens fragment were determined. The gasses and particles generated were analysed using gas chromatography mass spectrometer (GC-MS) and total organic carbon analyzer (TOC), respectively. Results: In vitro the IOL fragments easily separated at the lowest commercially available energy setting of 1 μJ, 8-μm spot, and 2-μm line separation. No particles were detected in the 0.5- to 900-μm range. No significant gasses or other organic breakdown by products were detected at this setting. At much higher energy levels 12 μJ (4 × 6 μm spot and line separation) significant pyrolytic products were detected, which could be harmful to the eye. In cadaveric explanted IOL capsule complex the laser pulses could be applied through the capsule to the IOL and successfully fragment the IOL. Conclusion: IOL transection is feasible with femtosecond lasers. Further in vivo animal studies are required to confirm safety. Translational Relevance: In clinical practice there are a number of large intraocular lenses that can be difficult to explant. This in-vitro study examines the possibility of transecting the lasers quickly using femtosecond lasers. If in-vivo studies are successful, then this innovation could help ophthalmic surgeons in IOL explantation. PMID:26101721

  1. Combined ab interno trabeculotomy and lens extraction: a novel management option for combined uveitic and chronic narrow angle raised intraocular pressure.

    PubMed

    Lin, Siying; Gupta, Bhaskar; Rossiter, Jonathan

    2016-02-01

    Minimally invasive glaucoma surgery is a developing area that has the potential to replace traditional glaucoma surgery, with its known risk profile, but at present there are no randomised controlled data to validate its use. We report on a case where sequential bilateral combined ab interno trabeculotomy and lens extraction surgery was performed on a 45-year-old woman with combined uveitic and chronic narrow angle raised intraocular pressure. Maximal medical management alone could not control the intraocular pressure. At 12-month follow-up, the patient had achieved stable intraocular pressure in both eyes on a combination of topical ocular antiglaucomatous and steroid therapies. This case demonstrates the effectiveness of trabecular meshwork ablation via ab interno trabeculotomy in a case of complex mixed mechanism glaucoma. 2016 BMJ Publishing Group Ltd.

  2. Intracapsular lens extraction for the treatment of pupillary block glaucoma associated with anterior subluxation of the crystalline lens.

    PubMed

    Kim, Yong Joon; Ha, Seung Joo

    2013-01-01

    To report a case of pupillary block glaucoma associated with spontaneous crystalline lens subluxation into the anterior chamber in a 34-year-old man. Dry vitrectomy was performed for securing enough retrolental space, and an intracapsular lens extraction was then performed via a corneolimbal incision. Additional endothelial cell damage was avoided with an injection of viscoelastics and gentle extraction of the crystalline lens. After deepening of the anterior chamber, scleral fixation of the intraocular lens was performed with an ab externo technique. Two months after the operation, a well-fixated intraocular lens was observed and intraocular pressure was stable. The postoperative corneal astigmatism was -3.5 dpt, and the patient had a best-corrected visual acuity of 20/25. Postoperative complications included decreased endothelial cell count and sector iris paralysis near the incision site. An anteriorly subluxated crystalline lens can cause pupillary block glaucoma in healthy young adults. To prevent intraoperative complications, intracapsular lens extraction with dry vitrectomy can be a good surgical option. The endothelial cell density should be closely monitored after surgery.

  3. Voltage-controlled IPMC actuators for accommodating intra-ocular lens systems

    NASA Astrophysics Data System (ADS)

    Horiuchi, Tetsuya; Mihashi, Toshifumi; Fujikado, Takashi; Oshika, Tetsuro; Asaka, Kinji

    2017-04-01

    An ion polymer-metal composite (IPMC) actuator has unique performance characteristics that were applied in this study for use within the eye. Cataracts are a common eye disease causing clouding of the lens. To treat cataracts, surgeons replace clouded lenses with intraocular lenses (IOLs). However, patients who receive this treatment must still wear reading glasses for tasks requiring close-up vision. We suggest a new voltage-controlled accommodating IOL consisting of an IPMC actuator to change the lens’ focus. We examined the relationship between the displacement performance of an IPMC actuator and the accommodating range of the IOL using in vitro experiments. We show that this system has an accommodating range of approximately 1.15 D under an applied voltage of ±1.2 V. By Lagrange interpolation, we estimate that with an IPMC actuator displacement of 0.14 mm, we can achieve a refractive power of 4 D, which is equivalent to the accommodating range of a 40 year old person.

  4. The impact of intraocular pressure on elastic wave velocity estimates in the crystalline lens.

    PubMed

    Park, Suhyun; Yoon, Heechul; Larin, Kirill V; Emelianov, Stanislav Y; Aglyamov, Salavat R

    2016-12-20

    Intraocular pressure (IOP) is believed to influence the mechanical properties of ocular tissues including cornea and sclera. The elastic properties of the crystalline lens have been mainly investigated with regard to presbyopia, the age-related loss of accommodation power of the eye. However, the relationship between the elastic properties of the lens and IOP remains to be established. The objective of this study is to measure the elastic wave velocity, which represents the mechanical properties of tissue, in the crystalline lens ex vivo in response to changes in IOP. The elastic wave velocities in the cornea and lens from seven enucleated bovine globe samples were estimated using ultrasound shear wave elasticity imaging. To generate and then image the elastic wave propagation, an ultrasound imaging system was used to transmit a 600 µs pushing pulse at 4.5 MHz center frequency and to acquire ultrasound tracking frames at 6 kHz frame rate. The pushing beams were separately applied to the cornea and lens. IOP in the eyeballs was varied from 5 to 50 mmHg. The results indicate that while the elastic wave velocity in the cornea increased from 0.96  ±  0.30 m s -1 to 6.27  ±  0.75 m s -1 as IOP was elevated from 5 to 50 mmHg, there were insignificant changes in the elastic wave velocity in the crystalline lens with the minimum and the maximum speeds of 1.44  ±  0.27 m s -1 and 2.03  ±  0.46 m s -1 , respectively. This study shows that ultrasound shear wave elasticity imaging can be used to assess the biomechanical properties of the crystalline lens noninvasively. Also, it was observed that the dependency of the crystalline lens stiffness on the IOP was significantly lower in comparison with that of cornea.

  5. Prevention of increased abnormal fundus autofluorescence with blue light-filtering intraocular lenses.

    PubMed

    Nagai, Hiroyuki; Hirano, Yoshio; Yasukawa, Tsutomu; Morita, Hiroshi; Nozaki, Miho; Wolf-Schnurrbusch, Ute; Wolf, Sebastian; Ogura, Yuichiro

    2015-09-01

    To observe changes in fundus autofluorescence 2 years after implantation of blue light-filtering (yellow-tinted) and ultraviolet light-filtering (colorless) intraocular lenses (IOLs). Department of Ophthalmology and Visual Science, Nagoya City University Graduate School of Medical Sciences, Nagoya, Japan, and the Department of Ophthalmology, University of Bern, Bern, Switzerland. Prospective comparative observational study. Patients were enrolled who had cataract surgery with implantation of a yellow-tinted or colorless IOL and for whom images were obtained on which the fundus autofluorescence was measurable using the Heidelberg Retina Angiogram 2 postoperatively. The fundus autofluorescence in the images was classified into 8 abnormal patterns based on the classification of the International Fundus Autofluorescence Classification Group, The presence of normal fundus autofluorescence, geographic atrophy, and wet age-related macular degeneration (AMD) also was recorded. The fundus findings at baseline and 2 years postoperatively were compared. Fifty-two eyes with a yellow-tinted IOL and 79 eyes with a colorless IOL were included. Abnormal fundus autofluorescence did not develop or increase in the yellow-tinted IOL group; however, progressive abnormal fundus autofluorescence developed or increased in 12 eyes (15.2%) in the colorless IOL group (P = .0016). New drusen, geographic atrophy, and choroidal neovascularization were observed mainly in the colorless IOL group. The incidence of AMD was statistically significantly higher in the colorless IOL group (P = .042). Two years after cataract surgery, significant differences were seen in the progression of abnormal fundus autofluorescence between the 2 groups. The incidence of AMD was lower in eyes with a yellow-tinted IOL. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  6. Toric multifocal intraocular lens implantation in a case of bilateral anterior and posterior lenticonus in Alport syndrome

    PubMed Central

    Ladi, Jeevan S; Shah, Nitant A

    2016-01-01

    We report the first case of toric multifocal intraocular lens (IOL) implantation in both the eyes of a young patient of Alport syndrome with anterior and posterior lenticonus with a successful outcome. An 18-year-old female patient presented with progressively blurred vision in both eyes since 4–5 years not improving with glasses. Refraction showed high myopia with astigmatism; however, the vision did not improve beyond 6/60 with glasses correction. Clinical examination on slit lamp showed anterior and posterior lenticonus bilaterally with a classical oil droplet appearance. We performed clear lens extraction by phacoemulsification with toric multifocal IOL implantation in both eyes. Postoperatively, the patient achieved an excellent refractive outcome with the unaided vision of 6/9, N6 in both eyes. PMID:27958211

  7. Optical Fourier filtering for whole lens assessment of progressive power lenses.

    PubMed

    Spiers, T; Hull, C C

    2000-07-01

    Four binary filter designs for use in an optical Fourier filtering set-up were evaluated when taking quantitative measurements and when qualitatively mapping the power variation of progressive power lenses (PPLs). The binary filters tested were concentric ring, linear grating, grid and "chevron" designs. The chevron filter was considered best for quantitative measurements since it permitted a vernier acuity task to be used for measuring the fringe spacing, significantly reducing errors, and it also gave information on the polarity of the lens power. The linear grating filter was considered best for qualitatively evaluating the power variation. Optical Fourier filtering and a Nidek automatic focimeter were then used to measure the powers in the distance and near portions of five PPLs of differing design. Mean measurement error was 0.04 D with a maximum value of 0.13 D. Good qualitative agreement was found between the iso-cylinder plots provided by the manufacturer and the Fourier filter fringe patterns for the PPLs indicating that optical Fourier filtering provides the ability to map the power distribution across the entire lens aperture without the need for multiple point measurements. Arguments are presented that demonstrate that it should be possible to derive both iso-sphere and iso-cylinder plots from the binary filter patterns.

  8. Development and experimental verification of an intraocular scattering model

    NASA Astrophysics Data System (ADS)

    Jiang, Chong-Jhih; Jhong, Tian-Siang; Chen, Yi-Chun; Sun, Ching-Cherng

    2011-10-01

    An intraocular scattering model was constructed in human eye model and experimentally verified. According to the biometric data, the volumetric scattering in crystalline lens and diffusion at retina fundus were developed. The scattering parameters of cornea, including particle size and obscuration ratio, were varied to make the veiling luminance of the eye model matching the CIE disability glare general formula. By replacing the transparent lens with a cataractous lens, the disability glare curve of cataracts was generated and compared with that of transparent lenses. The MTF of the intraocular scattering model showed nice correspondence with the data measured by a double-pass experiment.

  9. Capsular bag opacification after experimental implantation of a new accommodating intraocular lens in rabbit eyes.

    PubMed

    Werner, Liliana; Pandey, Suresh K; Izak, Andrea M; Vargas, Luis G; Trivedi, Rupal H; Apple, David J; Mamalis, Nick

    2004-05-01

    To evaluate the development of capsular bag opacification in rabbit eyes after implantation of an intraocular lens (IOL) designed to minimize contact between the anterior capsule and the IOL and ensure expansion of the capsular bag. David J. Apple, MD Laboratories for Ophthalmic Devices Research, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. Ten New Zealand white rabbits had a study IOL (new accommodating silicone IOL [Synchrony, Visiogen, Inc.]) implanted in 1 eye and a control IOL (1-piece plate silicone IOL with large fixation holes) implanted in the other eye. Intraocular lens position, anterior capsule opacification (ACO), and posterior capsule opacification (PCO) were qualitatively assessed using slitlamp retroillumination photographs of the dilated eyes. Anterior capsule opacification and PCO were graded on a 0 to 4 scale after the eyes were enucleated (Miyake-Apple posterior and anterior views after excision of the cornea and iris). The eyes were also evaluated histopathologically. The rate of ACO and PCO was significantly higher in the control group. Fibrosis and ACO were almost absent in the study group; the control group exhibited extensive capsulorhexis contraction, including capsulorhexis occlusion. Postoperative IOL dislocation into the anterior chamber and pupillary block syndrome were observed in some eyes in the study group. The special design features associated with the study IOL appeared to help prevent PCO. Complications in the study group were probably caused by the increased posterior vitreous pressure in rabbit eyes compared to human eyes and the relatively large size of the study IOL relative to the anterior segment of rabbit eyes.

  10. Application of a three-lens slit spatial filter in high power lasers

    NASA Astrophysics Data System (ADS)

    Xiong, Han

    2018-07-01

    Combined with partial parameters in National Ignition Facility, the conceptual design of off-axial four-pass main laser optical system with a three-lens slit spatial filter has been discussed. Since the three-lens slit spatial filter can decline the focal intensity by about 3 orders of magnitudes than that in NIF system, the cutoff frequency in main amplifier cavity can be reduced from 51 × DL to 39 × DL for better beam quality. The main laser system for single beam line can be shortened from 174.7 m to 155.7 m and the spatial filter in high vacuum becomes 60 m instead of the original 83.5 m. Additionally, the pinhole closure could be avoided since the declining of focal intensity in slit spatial filter and the absence of pinhole aperture in the other (pinhole) spatial filter, which provides new ideas for the future high-power lasers.

  11. The effectiveness of early lens extraction with intraocular lens implantation for the treatment of primary angle-closure glaucoma (EAGLE): study protocol for a randomized controlled trial.

    PubMed

    Azuara-Blanco, Augusto; Burr, Jennifer M; Cochran, Claire; Ramsay, Craig; Vale, Luke; Foster, Paul; Friedman, David; Quayyum, Zahidul; Lai, Jimmy; Nolan, Winnie; Aung, Tin; Chew, Paul; McPherson, Gladys; McDonald, Alison; Norrie, John

    2011-05-23

    Glaucoma is the leading cause of irreversible blindness. Although primary open-angle glaucoma is more common, primary angle-closure glaucoma (PACG) is more likely to result in irreversible blindness. By 2020, 5·3 million people worldwide will be blind because of PACG. The current standard care for PACG is a stepped approach of a combination of laser iridotomy surgery (to open the drainage angle) and medical treatment (to reduce intraocular pressure). If these treatments fail, glaucoma surgery (eg, trabeculectomy) is indicated. It has been proposed that, because the lens of the eye plays a major role in the mechanisms leading to PACG, early clear lens extraction will improve glaucoma control by opening the drainage angle. This procedure might reduce the need for drugs and glaucoma surgery, maintain good visual acuity, and improve quality of life compared with standard care.EAGLE aims to evaluate whether early lens extraction improves patient-reported, clinical outcomes, and cost-effectiveness, compared with standard care. EAGLE is a multicentre pragmatic randomized trial. All people presenting to the recruitment centres in the UK and east Asia with newly diagnosed PACG and who are at least 50 years old are eligible.The primary outcomes are EQ-5D, intraocular pressure, and incremental cost per quality adjusted life year (QALY) gained. Other outcomes are: vision and glaucoma-specific patient-reported outcomes, visual acuity, visual field, angle closure, number of medications, additional surgery (e.g., trabeculectomy), costs to the health services and patients, and adverse events.A single main analysis will be done at the end of the trial, after three years of follow-up. The analysis will be based on all participants as randomized (intention to treat). 400 participants (200 in each group) will be recruited, to have 90% power at 5% significance level to detect a difference in EQ-5D score between the two groups of 0·05, and a mean difference in intraocular pressure of

  12. The effectiveness of early lens extraction with intraocular lens implantation for the treatment of primary angle-closure glaucoma (EAGLE): study protocol for a randomized controlled trial

    PubMed Central

    2011-01-01

    Background Glaucoma is the leading cause of irreversible blindness. Although primary open-angle glaucoma is more common, primary angle-closure glaucoma (PACG) is more likely to result in irreversible blindness. By 2020, 5·3 million people worldwide will be blind because of PACG. The current standard care for PACG is a stepped approach of a combination of laser iridotomy surgery (to open the drainage angle) and medical treatment (to reduce intraocular pressure). If these treatments fail, glaucoma surgery (eg, trabeculectomy) is indicated. It has been proposed that, because the lens of the eye plays a major role in the mechanisms leading to PACG, early clear lens extraction will improve glaucoma control by opening the drainage angle. This procedure might reduce the need for drugs and glaucoma surgery, maintain good visual acuity, and improve quality of life compared with standard care. EAGLE aims to evaluate whether early lens extraction improves patient-reported, clinical outcomes, and cost-effectiveness, compared with standard care. Methods/Design EAGLE is a multicentre pragmatic randomized trial. All people presenting to the recruitment centres in the UK and east Asia with newly diagnosed PACG and who are at least 50 years old are eligible. The primary outcomes are EQ-5D, intraocular pressure, and incremental cost per quality adjusted life year (QALY) gained. Other outcomes are: vision and glaucoma-specific patient-reported outcomes, visual acuity, visual field, angle closure, number of medications, additional surgery (e.g., trabeculectomy), costs to the health services and patients, and adverse events. A single main analysis will be done at the end of the trial, after three years of follow-up. The analysis will be based on all participants as randomized (intention to treat). 400 participants (200 in each group) will be recruited, to have 90% power at 5% significance level to detect a difference in EQ-5D score between the two groups of 0·05, and a mean

  13. [Slit lamp optical coherence tomography study of anterior segment changes after phacoemulsification and foldable intraocular lens implantation].

    PubMed

    Yan, Pi-song; Zhang, Zhen-ping; Lin, Hao-tian; Wu, Wen-jie; Bai, Ling

    2009-09-01

    To investigate quantitative changes of the anterior segment configuration after clear corneal incision phacoemulsification and foldable intraocular lens (IOL) implantation with slit-lamp-adapted optical coherence tomography (SL-OCT). In prospective consecutive case series, clear corneal incision phacoemulsification and foldable intraocular lens implantation were performed in 44 eyes of 40 patients. The changes of the anterior segment configuration were performed by SL-OCT before and 1 day, 1 week, 2 weeks and 1 month after surgery. SPSS 16.0 software was used to analyze statistical difference. For all patients, the central corneal thickness (CCT) and the incisional corneal thickness (ICT) increased significantly 1 day after surgery (CCT increased 99.59 microm, ICT increased 234.57 microm; P = 0.490). At 1 month, the CCT almost had returned to baseline, but the ICT had been thicker about 19.25 microm than baseline(P = 0.001). The measurements of ACD, AOD500, AOD750, TISA500, TISA750 also increased significantly 1 day after surgery. Although the ACD had no changes within 2 weeks (all P < 0.05), it had been not stable. The changes of the width of the anterior chamber had been stable in the early period after surgery (all P > 0.05). The SL-OCT could impersonality and quantificationally evaluate the anterior segment changes induced by cataract surgery.

  14. [Implantation of a sulcus-fixated toric additive intraocular lens in a case of high astigmatism after a triple procedure].

    PubMed

    Linz, K; Auffarth, G U; Kretz, F T A

    2014-08-01

    Residual refractive errors, especially high-grade astigmatism after penetrating keratoplasty, often lead to a significant loss of vision. If high anismetropia could not be corrected with glasses or contact lenses, different kinds of surgical procedures are available for visual rehabilitation (intraocular lens exchange, astigmatic keratotomy, Excimer laser treatment, intrastromal corneal ring segment implantation and additive intraocular lens implantation). Toric add-on IOLs are especially designed for sulcus implantation and correcting high astigmatism in pseudophakic eyes. All toric IOLs are individually manufactured according to subjective refraction and biometry. Depending on the underlying manufacturer high-grade astigmatism can be corrected with a cylindrical power up to + 30.0 D. A 74-year-old patient presented with endothelial decompensation and an uncorrected distance visual acuity (UDVA) of 1.0 logMAR for penetrating keratoplasty on the right eye due to a Fuchs endothelial dystrophy. Postoperatively, the uncorrected distance visual acuity improved to 0.8 logMAR, with pinhole correction to 0.5 logMAR. After removing the sutures a high and irregular corneal astigmatism of 21.0 D was found. The corrected distance visual acuity (CDVA) with a refraction of + 5.5 D sph, - 21.0 D cyl 90° was 0.24 logMAR. Therefore an individually manufactured toric additive intraocular lens of + 25.0 D cylindrical and - 18.0 D spherical power for sulcus implantation was chosen and implanted uneventfully. Eight months after surgery refractive astigmatism was reduced significantly to - 0.75 D with an UDVA of 0.08 logMAR and a CDVA of 0.02 logMAR. During the 8-months follow-up period the additive IOL remained centered and no IOL rotation could be observed. Toric add-on IOLs are a safe and successful method for reducing high astigmatism and anisometropia after penetrating keratoplasty. One of the main advantages is the reversibility of the procedure by an explantation of

  15. Intraocular pressure measurement over soft contact lens by rebound tonometer: a comparative study

    PubMed Central

    Nacaroglu, Senay Asik; Un, Emine Seker; Ersoz, Mehmet Giray; Tasci, Yelda

    2015-01-01

    AIM To evaluate the intraocular pressure (IOP) measurements by Icare rebound tonometer over a contact lens in comparison with Goldmann applanation tonometry (GAT). METHODS Fifty patients using contact lens were included in this study. One of the eyes of the patients was selected randomly and their IOP were measured by rebound tonometer with and without contact lens (RTCL, RT respectively) and by GAT, as well as their central corneal thickness (CCT) by optical pachymeter. The results of both methods were compared by correlation analysis, general linear method repeated measure and Bland-Altman analysis. RESULTS Mean IOP values measured by RTCL, RT and GAT were 15.68±3.7, 14.50±3.4 and 14.16±2.8 (P<0.001), respectively. Mean IOP by RTCL was significantly higher than the measurements implemented by RT and GAT (P<0.001), while there was no difference between the measurements by GAT and RT (P=0.629). There was a good level of positive correlation between GAT and RTCL as well as RT (r=0.786 P<0.001, r=0.833 P<0.001, respectively). We have observed that CCT increase did not show any correlation with the differences of the measurements between RTCL and RT (P=0.329), RTCL and GAT (P=0.07) as well as RT and GAT (P=0.189) in linear regression model. CONCLUSION The average of the measurements over contact lens by rebound tonometer was found to be higher than what was measured by GAT. Although this difference is statistically significant, it may be clinically negligible in the normal population. PMID:26086004

  16. SURGICAL OUTCOME OF SIMULTANEOUS INTRAOCULAR LENS RESCUE AND SUTURELESS INTRASCLERAL TUNNEL FIXATION OF DISLOCATED INTRAOCULAR LENSES.

    PubMed

    Kim, Min; Lee, Dong H; Koh, Hyoung J; Lee, Sung C; Kim, Sung S

    2015-07-01

    To report short-term surgical outcomes of single-stage simultaneous rescue and sutureless intrascleral fixation of dislocated intraocular lens (IOLs). Sixteen eyes of 16 patients who underwent simultaneous rescue and intrascleral fixation of dislocated 3-piece IOLs were retrospectively evaluated. Partial thickness limbal-based scleral flaps (2.0 × 2.0 mm) were created, and a 22-gauge round needle was used to create a sclerotomy at 1.5 mm from the limbus under the previously created scleral flap, and a 23-gauge trans pars plana vitrectomy was performed. Bimanual maneuvers using two 23-gauge end-grasping forceps under chandelier illumination and a wide-angle viewing system enabled 1 step rescue of IOLs from the posterior vitreous cavity with 1 hand and simultaneous haptic externalization through sclerotomy with the other hand. An externalized haptic was placed into the 3-mm intrascleral tunnel created using a bent 26-gauge needle. Fibrin glue was used to fixate haptics and close the scleral flaps. Intraocular lenses were successfully rescued and sclera-fixated through intrascleral tunnels in all 16 eyes (mean age, 56.56 ± 19.89 years). The mean preoperative logarithm of the minimum angle of resolution best-corrected visual acuity was 0.92 ± 0.68, and this significantly improved at 6 months to 0.289 ± 0.36 (P = 0.003). During the follow-up period (10.1 ± 3.21 months), no significant change of endothelial cell count or central foveal thickness was noted postoperatively (P = 0.203 and P = 0.979, respectively). There were no significant postoperative complications such as IOL dislocation, IOL decentration, retinal detachment, endophthalmitis, or postoperative hypotony. Simultaneous rescue and sutureless intrascleral haptic fixation of dislocated 3-piece IOLs using bimanual maneuvers is an effective, safe, and minimally invasive surgical method to rescue and fixate the dislocated IOL without further explant.

  17. Combining primary and piggyback intraocular lenses to treat extreme myopic astigmatism in stable keratoconus following cataract surgery.

    PubMed

    Goh, Yi Wei; Misra, Stuti; Patel, Dipika V; McGhee, Charles N J

    2013-03-01

    The majority of those with keratoconus can maximise visual acuity with spectacle or contact lens correction as they age; however, as subjects enter their sixties, cataracts may supervene and contact lens tolerance diminishes with consequent reduction in visual acuity. Following cataract extraction, the complex refractive error associated with keratoconus may not be readily corrected by an intraocular lens alone. This report highlights the planned implantation of a primary posterior chamber toric intraocular lens with a secondary piggyback, sulcus-based, intraocular lens in advanced but stable keratoconus with extreme myopic astigmatism and cataract. © 2013 The Authors. Clinical and Experimental Optometry © 2013 Optometrists Association Australia.

  18. Accommodative intraocular lens versus standard monofocal intraocular lens implantation in cataract surgery.

    PubMed

    Ong, Hon Shing; Evans, Jennifer R; Allan, Bruce D S

    2014-05-01

    Following cataract surgery and intraocular lens (IOL) implantation, loss of accommodation or postoperative presbyopia occurs and remains a challenge. Standard monofocal IOLs correct only distance vision; patients require spectacles for near vision. Accommodative IOLs have been designed to overcome loss of accommodation after cataract surgery. To define (a) the extent to which accommodative IOLs improve unaided near visual function, in comparison with monofocal IOLs; (b) the extent of compromise to unaided distance visual acuity; c) whether a higher rate of additional complications is associated the use of accommodative IOLs. We searched CENTRAL (which contains the Cochrane Eyes and Vision Group Trials Register) (The Cochrane Library 2013, Issue 9), Ovid MEDLINE, Ovid MEDLINE in-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily Update, Ovid OLDMEDLINE (January 1946 to October 2013), EMBASE (January 1980 to October 2013), Latin American and Caribbean Health Sciences Literature Database (LILACS) (January 1982 to October 2013), the metaRegister of Controlled Trials (mRCT) (www.controlled-trials.com), ClinicalTrials.gov (www.clinicaltrial.gov) and the WHO International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 10 October 2013. We include randomised controlled trials (RCTs) which compared implantation of accommodative IOLs to implantation of monofocal IOLs in cataract surgery. Two authors independently screened search results, assessed risk of bias and extracted data. All included trials used the 1CU accommodative IOL (HumanOptics, Erlangen, Germany) for their intervention group. One trial had an additional arm with the AT-45 Crystalens accommodative IOL (Eyeonics Vision). We performed a separate analysis comparing 1CU and AT-45 IOL. We included four RCTs, including 229 participants (256 eyes

  19. Calculating Solar Ultraviolet Irradiation Of The Human Cornea And Corresponding Required Sunglass Lens Transmittances

    NASA Astrophysics Data System (ADS)

    Hoover, Herbert L.; Marsaud, Serge G.

    1986-05-01

    Tinted ophthalmic lenses are used primarily for eye comfort in a brightly lit environment. An ancillary benefit is the attenuation of ultraviolet radiation. Some national product standards specify quantitative limits for ultraviolet transmittances. Such limits ought to be founded on quantitative estimates of solar irradiances of ocular tissues, with actinic effectiveness taken into account. We use the equations of Green and coworkers for direct and diffuse solar irradiance at the earth's surface to calculate average sky and ground spectral radiances. We use the geometric factors derived by us for the coupling of radiation from these sources to the human cornea. Actinically weighted corneal spectral irradiances integrated over wavelength and time yield peak irradiances and accumulated exposure doses that are compared with recommended exposure limits. This provides the maximal effective ultraviolet transmittances of tinted ophthalmic lenses such that these exposure limits will not be exceeded in the selected exposure environment. The influences on corneal irradiation of such exposure parameters as solar zenith angle, altitude of the exposure site, characteristics of atmospheric aerosols, and ground reflectances are illustrated. The relationships between the effective transmittance (which is a function of the environmental radiation and any actinicweighting function) and readily determined characteristics of the lens itself, viz., its mean transmittance, and a selected spectral transmittance, are derived for three lens transmittance curves. Limits of lens transmittance for the UV-B and UV-A wavelength regions are presented for several representative exposure sites in Europe and the U.S.A.

  20. Crystalens HD intraocular lens analysis using an adaptive optics visual simulator.

    PubMed

    Pérez-Vives, Cari; Montés-Micó, Robert; López-Gil, Norberto; Ferrer-Blasco, Teresa; García-Lázaro, Santiago

    2013-12-01

    To compare visual and optical quality of the Crystalens HD intraocular lens (IOL) with that of a monofocal IOL. The wavefront aberration patterns of the monocular Akreos Adapt AO IOL and the single-optic accommodating Crystalens HD IOL were measured in a model eye. The Crystalens IOL was measured in its nonaccommodative state and then, after flexing the haptic to produce 1.4 mm of movement, in its accommodative state. Using an adaptive optics system, subjects' aberrations were removed and replaced with those of pseudophakes viewing with either lens. Monocular distance visual acuity (DVA) at high (100%), medium (50%), and low (10%) contrast and contrast sensitivity (CS) were measured for both IOL optics. Near VA (NVA) and CS were measured for the Crystalens HD IOL in its accommodative state. Depth of focus around the distance and near focus was also evaluated for the Crystalens HD IOL. Modulation transfer function (MTF), point spread function (PSF), and Strehl ratio were also calculated. All measures were taken for 3- and 5-mm pupils. The MTF, PSF, and Strehl ratio showed comparable values between IOLs (p > 0.05). There were no significant differences in DVA and CS between IOLs for all contrasts and pupils (p > 0.05). When spherically focused, mean DVA and NVA with the Crystalens HD IOL were ≥20/20 at 100 and 50% contrasts for both pupils. Monocular DVA, NVA, and CS were slightly better with 3- than 5-mm pupils, but without statistically significant differences. The Crystalens HD IOL showed about 0.75 and 0.50 D of depth of focus in its accommodative state and nonaccommodative state, respectively. The optical and visual quality with the nonaccommodatied Crystalens HD IOL was comparable to that of a monofocal IOL. If this lens can move 1.4 mm in the eye, it will provide high-quality optics for near vision as well.

  1. Comparison of holographic lens and filter systems for lateral spectrum splitting

    NASA Astrophysics Data System (ADS)

    Vorndran, Shelby; Chrysler, Benjamin; Kostuk, Raymond K.

    2016-09-01

    Spectrum splitting is an approach to increasing the conversion efficiency of a photovoltaic (PV) system. Several methods can be used to perform this function which requires efficient spatial separation of different spectral bands of the incident solar radiation. In this paper several of holographic methods for implementing spectrum splitting are reviewed along with the benefits and disadvantages associated with each approach. The review indicates that a volume holographic lens has many advantages for spectrum splitting in terms of both power conversion efficiency and energy yield. A specific design for a volume holographic spectrum splitting lens is discussed for use with high bandgap InGaP and low bandgap silicon PV cells. The holographic lenses are modeled using rigorous coupled wave analysis, and the optical efficiency is evaluated using non-sequential raytracing. A proof-of-concept off-axis holographic lens is also recorded in dichromated gelatin film and the spectral diffraction efficiency of the hologram is measured with multiple laser sources across the diffracted spectral band. The experimental volume holographic lens (VHL) characteristics are compared to an ideal spectrum splitting filter in terms of power conversion efficiency and energy yield in environments with high direct normal incidence (DNI) illumination and high levels of diffuse illumination. The results show that the experimental VHL can achieve 62.5% of the ideal filter power conversion efficiency, 64.8% of the ideal filter DNI environment energy yield, and 57.7% of the ideal diffuse environment energy yield performance.

  2. Intraocular lens based on double-liquid variable-focus lens.

    PubMed

    Peng, Runling; Li, Yifan; Hu, Shuilan; Wei, Maowei; Chen, Jiabi

    2014-01-10

    In this work, the crystalline lens in the Gullstrand-Le Grand human eye model is replaced by a double-liquid variable-focus lens, the structure data of which are based on theoretical analysis and experimental results. When the pseudoaphakic eye is built in Zemax, aspherical surfaces are introduced to the double-liquid variable-focus lens to reduce the axial spherical aberration existent in the system. After optimization, the zoom range of the pseudoaphakic eye greatly exceeds that of normal human eyes, and the spot size on an image plane basically reaches the normal human eye's limit of resolution.

  3. Optical bench performance of a novel trifocal intraocular lens compared with a multifocal intraocular lens

    PubMed Central

    Lee, Shinwook; Choi, Myoung; Xu, Zaiwei; Zhao, Zeyu; Alexander, Elsinore; Liu, Yueai

    2016-01-01

    Purpose The purpose of this study is to compare the optical characteristics of the novel PanOptix presbyopia-correcting trifocal intraocular lens (IOL) and the multifocal ReSTOR +3.0 D IOL, through in vitro bench investigations. Methods The optical characteristics of AcrySof® IQ PanOptix™ (PanOptix) and AcrySof® IQ ReSTOR +3.0 D (ReSTOR +3.0 D) IOLs were evaluated by through-focus Badal images, simulated headlight images, and modulation transfer function (MTF) measurements which determine resolution, photic phenomena, and image quality. Through-focus Badal images of an Early Treatment of Diabetic Retinopathy Study chart were recorded at both photopic and mesopic pupil sizes. Simulated headlight images were taken on an MTF bench with a 50-μm pinhole target and a 5.0 mm pupil at the distance focus of the IOL. MTF curves were measured with a 3.0 mm pupil, and spatial frequencies equivalent to 20/40 and 20/20 visual acuities were recorded to illustrate the through-focus MTF curves. Far-, intermediate-, and near-focus MTF values were obtained. Results Bench Badal image testing and MTF measurements showed that PanOptix has a near focus at a distance of 42 cm and an additional intermediate focus at a distance of about 60 cm. The near focus for ReSTOR +3.0 D is at 45 cm. PanOptix and ReSTOR +3.0 D have comparable photopic distances and near MTF values. Additionally, PanOptix provided a substantial continuous range of vision from distance to intermediate and to near compared with ReSTOR +3.0 D. The halo propensity for PanOptix was slightly higher than that for ReSTOR +3.0 D. Conclusion Laboratory-based in vitro simulations showed that PanOptix trifocal IOL has comparable resolution and image quality performance in distance and near foci compared with ReSTOR +3.0 D IOL. PanOptix showed better resolution and image quality performance at the intermediate focus than ReSTOR +3.0 D IOL. PMID:27330273

  4. Management of corneal decompensation 4 decades after Sputnik intraocular lens implantation.

    PubMed

    Hirji, Nashila; Nanavaty, Mayank A

    2015-01-01

    We report an unusual case of corneal decompensation occurring four decades after complicated cataract extraction with implantation of a Sputnik intraocular lens (IOL) and highlight the clinical and practical issues faced in managing corneal decompensation with a Sputnik IOL. A 72-year-old woman presented with deterioration of the vision in her left eye, four decades after intracapsular cataract extraction with Sputnik IOL implantation. Ocular examination revealed diffuse corneal edema and thickened vitreous strands in the anterior chamber. Her best-corrected visual acuity (BCVA) worsened to 6/60 within 3 months. Anterior vitrectomy and inferior iridectomy combined with Desçemet-stripping automated endothelial keratoplasty was performed. The procedure was successful, with the patient achieving best-corrected visual acuity of 6/6 at 8 months postoperatively. Corneal decompensation after Sputnik IOL implantation can occur four decades later. When the historical preoperative visual acuity is good in such cases, careful anterior vitrectomy with Desçemet-stripping automated endothelial keratoplasty provides good visual rehabilitation.

  5. Erythemal irradiances of filtered ultraviolet radiation

    NASA Astrophysics Data System (ADS)

    Parisi, A. V.; Wong, J. C. F.

    1997-07-01

    A spectrum evaluator employing four passive dosimeters has been used to evaluate the time averaged spectrum to allow calculation of the erythemal exposures resulting from the predominantly UVA component of filtered solar ultraviolet radiation. An exposure interval of approximately 20 min to autumn and spring sunshine was required for the spectrum evaluator to allow evaluation of the filtered source spectrum. For a clear spring day an erythemal exposure of 0.85 MED (minimum erythemal dose) to a horizontal plane and 0.38 MED to a vertical plane over a 6 h period was measured within a glass enclosure. For a partially cloudy day six weeks later, these were 0.89 and 0.44 MED for the horizontal and the vertical planes respectively. The ratios of the filtered to the unfiltered erythemal exposures within and outside the enclosure respectively ranged from 0.08 to 0.18 throughout the two days.

  6. Solving intraocular lens-related pigment dispersion syndrome with repositioning of primary sulcus implanted single-piece IOL in the capsular bag.

    PubMed

    Kohnen, Thomas; Kook, Daniel

    2009-08-01

    We describe 2 cases of pigment dispersion syndrome (PDS) after uneventful phacoemulsification and implantation of a posterior chamber single-piece intraocular lens (IOL) with a sharp-edge design. In both cases, several days after IOL implantation, marked pigment dispersion was seen on the iris and in the trabecular meshwork, associated with an elevation in intraocular pressure (IOP). Thorough examination showed that the implanted IOL was in the ciliary sulcus. After surgical repositioning of both IOLs in the capsular bag, the pigment dispersion regressed and the IOP returned to normal limits. The 2 cases suggest that particularly in PDS patients, an IOL with an anterior sharp-edge design should be implanted in the capsular bag. Implantation in the ciliary sulcus should be avoided.

  7. Safety and efficacy of phacoemulsification and intraocular lens implantation through a small pupil using minimal iris manipulation.

    PubMed

    Papaconstantinou, Dimitris; Kalantzis, George; Brouzas, Dimitris; Kontaxakis, Anastasios; Koutsandrea, Chryssanthi; Diagourtas, Andreas; Georgalas, Ilias

    2016-01-01

    The aim of this study was to compare the results of phacoemulsification through a small pupil using minimal iris manipulation versus phacoemulsification through a well-dilated pupil. This prospective randomized control (comparative) study comprised 78 patients (group I) with a maximally dilated pupil size of ≤4.00 mm and 45 patients (group II) with dilated pupil size of ≥7.00 mm. In group I patients, only viscodilation and minimal push-and-pull iris stretching with two collar-button iris-retractor hooks were utilized without iris manipulation. Phacoemulsification was performed by two senior surgeons and the technique used consisted of either stop and chop or quick chop, infusion/aspiration of lens cortex, capsular bag refill with ocular viscoelastic devices, and implantation of an acrylic foldable intraocular lens. Patients were examined on the first day and 1 month postoperatively. Forty-six eyes of group I patients had pseudoexfoliation syndrome, eleven eyes had previous glaucoma surgery, 14 eyes had angle-closure or open-angle glaucoma, and seven eyes had posterior synechiae with iritis. In group I patients, the mean pupil size measured under an operating microscope was 3.2 mm preoperatively, 4.3 mm after viscoelastic and mechanical pupil dilation, and 4.1 mm at the end of a surgical procedure. Rupture of the zonular fibers occurred in six patients of group I and the intraocular lens was implanted in the sulcus. Small iris-sphincter rupture and small hemorrhages occurred in four eyes during pupillary manipulation, but they were not evident at the end of the surgery. In group II patients, no intraoperative complications occurred. Signs of significant corneal edema and iritis were observed more frequently in group I eyes (26 eyes and 20 eyes, respectively) on the first postoperative day in comparison with group II eyes (ten eyes and six eyes, respectively). Intraocular pressure was <20 mmHg in all eyes of both groups. One month postoperatively, the pupil was

  8. Neodymium:YAG laser cutting of intraocular lens haptics in vitro and in vivo.

    PubMed

    Feder, J M; Rosenberg, M A; Farber, M D

    1989-09-01

    Various complications following intraocular lens (IOL) surgery result in explantation of the lenses. Haptic fibrosis may necessitate cutting the IOL haptics prior to removal. In this study we used the neodymium: YAG (Nd:YAG) laser to cut polypropylene and poly(methyl methacrylate) (PMMA) haptics in vitro and in rabbit eyes. In vitro we were able to cut 100% of both haptic types successfully (28 PMMA and 30 polypropylene haptics). In rabbit eyes we were able to cut 50% of the PMMA haptics and 43% of the polypropylene haptics. Poly(methyl methacrylate) haptics were easier to cut in vitro and in vivo than polypropylene haptics, requiring fewer shots for transection. Complications of Nd:YAG laser use frequently interfered with haptic transections in rabbit eyes. Haptic transection may be more easily accomplished in human eyes.

  9. Anterior capsule contraction and intraocular lens decentration and tilt after hydrogel lens implantation

    PubMed Central

    Hayashi, K.; Hayashi, H.; Nakao, F.; Hayashi, F.

    2001-01-01

    AIM—To prospectively investigate changes in the area of the anterior capsule opening, and intraocular lens (IOL) decentration and tilt after implantation of a hydrogel IOL.
METHODS—100 patients underwent implantation of a hydrogel IOL in one eye and an acrylic IOL implantation in the opposite eye. The area of the anterior capsule opening, and the degree of IOL decentration and tilt were measured using the Scheimpflug videophotography system at 3 days, and at 1, 3, and 6 months postoperatively.
RESULTS—The mean anterior capsule opening area decreased significantly in both groups. At 6 months postoperatively, the area in the hydrogel group was significantly smaller than that in the acrylic group. The mean percentage of the area reduction in the hydrogel group was also significantly greater than that in the acrylic group, being 16.9% in the hydrogel group and 8.8% in the acrylic group. In contrast, IOL decentration and tilt did not progress in either group. No significant differences were found in the degree of IOL decentration and tilt throughout the follow up period.
CONCLUSIONS—Contraction of the anterior capsule opening was more extensive with the hydrogel IOL than with the acrylic IOL, but the degree of IOL decentration and tilt were similar for the two types of lenses studied.

 PMID:11673291

  10. INTRAOCULAR LENS POSITION IN COMBINED PHACOEMULSIFICATION AND VITREORETINAL SURGERY.

    PubMed

    Ozates, Serdar; Kiziltoprak, Hasan; Koc, Mustafa; Uzel, Mehmet Murat; Teke, Mehmet Yasin

    2017-10-09

    To assess the decentration and angle of tilt of the intraocular lens (IOL) according to the intravitreal tamponade types used in combined phacoemulsification and vitreoretinal surgery. This prospective and randomized clinical study involved 73 eyes of 69 patients who underwent combined vitreoretinal surgery. Eyes with intravitreal tamponades formed the study group and eyes without intravitreal tamponades formed the control group. The study group was further divided into silicone oil and gas tamponade subgroups. Cross-sectional IOL images were captured using a Pentacam HR (Oculus, Germany) and tilt and decentration were calculated with Adobe Photoshop software (Adobe, San Jose, CA). The mean angle of tilt and decentration at the vertical meridian were significantly higher in both tamponade groups than in the control group (P < 0.05 for all). No significant difference was observed among the groups regarding IOL position parameters at the horizontal meridian (P > 0.05). When comparing the silicone oil and gas tamponade subgroups, no significant differences were noted on the position of IOL at both meridians (P > 0.05 for all). Intravitreal tamponades have an important effect on the position of IOL in combined vitreoretinal surgery. Silicone oil and gas tamponades may induce postoperative tilt and decentration of one-piece acrylic IOLs.

  11. The Effect of Lens Sphere and Cylinder Power on Residual Astigmatism and Its Resolution After Toric Intraocular Lens Implantation.

    PubMed

    Berdahl, John P; Hardten, David R; Kramer, Brent A; Potvin, Richard

    2017-03-01

    To analyze correlations between residual refractive cylinder (and its correction through lens reorientation) with the sphere and cylinder power of the toric intraocular lens (IOL) implanted. An online toric back-calculator (www.astigmatismfix.com) allows users to input toric IOL planning data, along with postoperative IOL orientation and refractive results; these data are used to determine the optimal orientation of the IOL to reduce refractive astigmatism. This was a retrospective data analysis; aggregate historical data were extracted from this calculator to investigate the relationship between residual refractive astigmatism and IOL cylinder and sphere power. A total of 12,812 records, 4,619 of which included IOL sphere power, were available for analysis. There was no significant effect of sphere power on residual refractive astigmatism (P = .25), but lower IOL cylinder powers were associated with significantly lower residual refractive astigmatism (P < .05). The difference between the intended and ideal orientation was higher in the lower IOL cylinder power groups (P < .01). Overcorrection of astigmatism was significantly more likely with higher IOL cylinder power (P < .01), but not with sphere power (P = .33). Reorientation to correct residual refractive cylinder to less than 0.50 diopters (D) was more successful with IOL cylinder powers of 1.50 D or less (P < .01); IOL sphere power had no apparent effect. There were significant effects of IOL cylinder power on residual refractive astigmatism, the difference between intended and ideal orientation, the likelihood of overcorrection, and the likelihood of astigmatism reduction with lens reorientation. IOL sphere power appeared to have no such effects. [J Refract Surg. 2017;33(3):157-162.]. Copyright 2017, SLACK Incorporated.

  12. Early lens extraction with intraocular lens implantation for the treatment of primary angle closure glaucoma: an economic evaluation based on data from the EAGLE trial

    PubMed Central

    Javanbakht, Mehdi; Azuara-Blanco, Augusto; Burr, Jennifer M; Ramsay, Craig; Cooper, David; Cochran, Claire; Norrie, John; Scotland, Graham

    2017-01-01

    Objective To investigate the cost-effectiveness of early lens extraction with intraocular lens implantation for the treatment of primary angle closure glaucoma (PACG) compared to standard care. Design Cost-effectiveness analysis alongside a multicentre pragmatic two-arm randomised controlled trial. Patients were followed-up for 36 months, and data on health service usage and health state utility were collected and analysed within the trial time horizon. A Markov model was developed to extrapolate the results over a 5-year and 10-year time horizon. Setting 22 hospital eye services in the UK. Population Males and females aged 50 years or over with newly diagnosed PACG or primary angle closure (PAC). Interventions Lens extraction compared to standard care (ie, laser iridotomy followed by medical therapy and glaucoma surgery). Outcome measures Costs of primary and secondary healthcare usage (UK NHS perspective), quality-adjusted life years (QALYs) and the incremental cost-effectiveness ratio (ICER) for lens extraction versus standard care. Results The mean age of participants was 67.5 (8.42), 57.5% were women, 44.6% had both eyes eligible, 1.4% were of Asian ethnicity and 35.4% had PAC. The mean health service costs were higher in patients randomised to lens extraction: £2467 vs £1486. The mean adjusted QALYs were also higher with early lens extraction: 2.602 vs 2.533. The ICER for lens extraction versus standard care was £14 284 per QALY gained at three years. Modelling suggests that the ICER may drop to £7090 per QALY gained by 5 years and that lens extraction may be cost saving by 10 years. Our results are generally robust to changes in the key input parameters and assumptions. Conclusions We find that lens extraction has a 67–89% chance of being cost-effective at 3 years and that it may be cost saving by 10 years. Trial registration number ISRCTN44464607; Results. PMID:28087548

  13. Photoprotection and photoreception of intraocular lenses under xenon and white LED illumination.

    PubMed

    Artigas, J M; Navea, A; García-Domene, M C; Artigas, C; Lanzagorta, A

    2016-05-01

    To analyze the photoprotection and phototransmission that various intraocular lenses (IOLs) provide under the illumination of a xenon (Xe) lamp and white LEDs (light emitting diode). The spectral transmission curves of six representative IOLs were measured using a Perkin-Elmer Lambda 35 UV/VIS spectrometer. Various filtering simulations were performed using a Xe lamp and white LEDs. The spectral emissions of these lamps were measured with an ILT-950 spectroradiometer. The IOLs analyzed primarily show transmission of nearly 100% in the visible spectrum. In the ultraviolet (UV) region, the filters incorporated in the various IOLs did not filter equally, and some of them let an appreciable amount of UV through. The Xe lamp presented a strong emission of ultraviolet A (UVA), and its emission under 300nm was not negligible. The white LED did not present an appreciable emission under 380nm. The cut-off wavelength of most filters is between 380 and 400nm (Physiol Hydriol60C(®), IOLTECH E4T(®), Alcon SA60AT(®), Alcon IQ SN60WF(®)), so that their UV protection is very effective. Nonetheless, the IOL OPHTEC Oculaid(®) contains a filter that, when a Xe lamp is used, lets through up to 20% for 350nm and up to 15% for 300nm, which at this point is ultraviolet B (UVB). The OPHTEC(®) Artisan IOL has a transmission peak below 300nm, which must be taken into account under Xe illumination. White LEDs do not emit energy below 380nm, so no special protection is required in the UV region. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  14. Effect of trabeculectomy on the accuracy of intraocular lens calculations in patients with open-angle glaucoma.

    PubMed

    Bae, Hyoung Won; Lee, Yun Ha; Kim, Do Wook; Lee, Taekjune; Hong, Samin; Seong, Gong Je; Kim, Chan Yun

    2016-08-01

    The objective of the study is to examine the effect of trabeculectomy on intraocular lens power calculations in patients with open-angle glaucoma (OAG) undergoing cataract surgery. The design is retrospective data analysis. There are a total of 55 eyes of 55 patients with OAG who had a cataract surgery alone or in combination with trabeculectomy. We classified OAG subjects into the following groups based on surgical history: only cataract surgery (OC group), cataract surgery after prior trabeculectomy (CAT group), and cataract surgery performed in combination with trabeculectomy (CCT group). Differences between actual and predicted postoperative refractive error. Mean error (ME, difference between postoperative and predicted SE) in the CCT group was significantly lower (towards myopia) than that of the OC group (P = 0.008). Additionally, mean absolute error (MAE, absolute value of ME) in the CAT group was significantly greater than in the OC group (P = 0.006). Using linear mixed models, the ME calculated with the SRK II formula was more accurate than the ME predicted by the SRK T formula in the CAT (P = 0.032) and CCT (P = 0.035) groups. The intraocular lens power prediction accuracy was lower in the CAT and CCT groups than in the OC group. The prediction error was greater in the CAT group than in the OC group, and the direction of the prediction error tended to be towards myopia in the CCT group. The SRK II formula may be more accurate in predicting residual refractive error in the CAT and CCT groups. © 2016 Royal Australian and New Zealand College of Ophthalmologists.

  15. Management of moderate and severe corneal astigmatism with AcrySof® toric intraocular lens implantation - Our experience.

    PubMed

    Farooqui, Javed Hussain; Koul, Archana; Dutta, Ranjan; Shroff, Noshir Minoo

    2015-01-01

    Visual performance following toric intraocular lens implantation for cataract with moderate and severe astigmatism. Cataract services, Shroff Eye Centre, New Delhi, India. Case series. This prospective study included 64 eyes of 40 patients with more than 1.50 dioptre (D) of pre-existing corneal astigmatism undergoing phacoemulsification with implantation of the AcrySof® toric IntraOcular Lens (IOL). The unaided visual acuity (UCVA), best corrected visual acuity (BCVA), residual refractive sphere and refractive cylinders were evaluated. Toric IOL axis and alignment error was measured by slit lamp method and Adobe Photoshop (version 7) method. Patient satisfaction was evaluated using a satisfaction questionnaire at 3 months. The mean residual refractive astigmatism was 0.57 D at the final follow-up of 3 months. Mean alignment error was 3.44 degrees (SD = 2.60) by slit lamp method and 3.88 degrees (SD = 2.86) by Photoshop method. Forty-six (71.9%) eyes showed misalignment of 5 degrees or less, and 60 (93.8%) eyes showed misalignment of 10 degrees or less. The mean log MAR UCVA at 1st post-op day was 0.172 (SD = 0.02), on 7th post-op day was 0.138 (SD = 0.11), and on 30th post-op day was 0.081 (SD = 0.11). The mean log MAR BCVA at three months was -0.04 (SD = 0.76). We believe that implantation of AcrySof® toric IOL is an effective, safe and predictable method to correct high amounts of corneal astigmatism during cataract surgery.

  16. Refractive outcomes after multifocal intraocular lens exchange.

    PubMed

    Kim, Eric J; Sajjad, Ahmar; Montes de Oca, Ildamaris; Koch, Douglas D; Wang, Li; Weikert, Mitchell P; Al-Mohtaseb, Zaina N

    2017-06-01

    To evaluate the refractive outcomes after multifocal intraocular lens (IOL) exchange. Cullen Eye Institute, Baylor College of Medicine, Houston, Texas, USA. Retrospective case series. Patients had multifocal IOL explantation followed by IOL implantation. Outcome measures included type of IOL, surgical indication, corrected distance visual acuity (CDVA), and refractive prediction error. The study comprised 29 patients (35 eyes). The types of IOLs implanted after multifocal IOL explantation included in-the-bag IOLs (74%), iris-sutured IOLs (6%), sulcus-fixated IOLs with optic capture (9%), sulcus-fixated IOLs without optic capture (9%), and anterior chamber IOLs (3%). The surgical indication for exchange included blurred vision (60%), photic phenomena (57%), photophobia (9%), loss of contrast sensitivity (3%), and multiple complaints (29%). The CDVA was 20/40 or better in 94% of eyes before the exchange and 100% of eyes after the exchange (P = .12). The mean refractive prediction error significantly decreased from 0.22 ± 0.81 diopter (D) before the exchange to -0.09 ± 0.53 D after the exchange (P < .05). The median absolute refractive prediction error significantly decreased from 0.43 D before the exchange to 0.23 D after the exchange (P < .05). Multifocal IOL exchange can be performed safely with good visual outcomes using different types of IOLs. A lower refractive prediction error and a higher likelihood of 20/40 or better vision can be achieved with the implantation of the second IOL compared with the original multifocal IOL, regardless of the final IOL position. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  17. [Refraction after Implantation of Multifocal and Presbyopia-Correcting Intraocular Lenses].

    PubMed

    Kretz, F T A; Linz, K; Mueller, M; Gerl, M; Koss, M J; Gerl, R H; Auffarth, G U

    2015-08-01

    Nowadays, further developments in the field of intraocular lenses offer a higher level of spectacle independence for our patients. As light gets scattered on different focal points a wider range of defocus is created. This greater defocus area makes it more difficult for us to determine the objective or subjective refraction. This contribution is concerned with the difficulties of measuring visual acuity in different intraocular lens designs and different measurement distances. Measuring refraction after implantation of a multifocal intraocular lens is a complex procedure and the experience of the examiner plays a crucial role. Retinoscopy, keratometry and the defocus curve are reliable methods for testing, while the auto refractometer, bichromatic testing and the cross-cylinder have limitations. Georg Thieme Verlag KG Stuttgart · New York.

  18. Secondary membrane formation after cataract surgery with primary intraocular lens implantation in children.

    PubMed

    Bar-Sela, Shai M; Har-Noy, Nurit Birman; Spierer, Abraham

    2014-08-01

    To evaluate the risk factors for secondary membrane (SM) formation after congenital cataract surgery with intraocular lens (IOL) implantation. A retrospective non-interventional comparative study. Thirty-nine patients (63 eyes) aged 1-135 months. The study included patients who underwent cataract extraction and primary IOL implantation between 1994 and 2001 at the University Hospital. The postoperative follow-up was 6-24 months. Thirty-three eyes received a poly(methyl methacrylate) (PMMA) IOL without square edges, 29 eyes received a hydrophobic acrylic IOL with truncated square edges (AcrySof), and there was no data for IOL type in one eye. Thirty-nine eyes had primary posterior capsulotomy (PPC) and anterior vitrectomy (AV) and in 24 eyes the posterior capsule was left intact. Cox proportional hazard regression analysis was performed to identify significant risk factors for SM formation, and Wilcoxon test to evaluate the difference in time from surgery to SM formation. SM developed in 24 eyes (38 %)--58 % of eyes with an intact posterior capsule and 26 % of eyes having PPC and AV, 42 % of eyes with a PMMA IOL, and 34 % of eyes with an AcrySof lens. In multivariate Cox regression analysis intraoperative PPC and AV (P = 0.02) and AcrySof lens implantation (P = 0.097) were associated with decreased postoperative incidence of SM formation. Median time until SM development was 2.9 months with PMMA IOLs (range 1-17 months) and 6 months with AcrySof lenses (range 1-21.8 months) (P = 0.037). Posterior capsule management as well as IOL design and material influence the incidence and the timing of SM formation after primary IOL implantation in children.

  19. Stability and safety of MA50 intraocular lens placed in the sulcus.

    PubMed

    Kemp, P S; Oetting, T A

    2015-11-01

    To describe the safety and stability of sulcus placement of the MA50 intraocular lens (IOL). Consecutive patients with MA50 IOLs placed in the sulcus at the University of Iowa Hospitals and Clinics, Iowa City, Iowa, USA, from 1997 to 2012 were identified. Inclusion criteria included patients with over 4 weeks of follow-up data. AEL was compared with incidence of IOL decentration using at two-tailed Student's t-test. Fifty eyes of 49 patients meeting the inclusion criteria were identified. Four weeks post-operatively, the average best-corrected visual acuity was 20/30. IOL decentration occurred in 14% of patients; patients with decentered IOLs had a significantly longer average AEL (25.37 mm) than patients whose IOL remained centered (23.94 mm, P=0.017). Other complications included uveitis-glaucoma-hyphema syndrome (12%), iritis (8%), and glaucoma (6%). There were no cases of pigment dispersion syndrome or need for lens exchange. Twelve eyes (24%) had intra-operative optic capture by the anterior capsule, none of which had post-operative decentration. The MA50 IOL is a reasonable, stable option for placement in the sulcus, with a low-risk profile; however, in eyes with longer AEL and presumably larger anterior segment, surgeons should consider placing an IOL with longer haptic distance than the MA50 to maintain centration. Optic capture of the MA50 IOL by the anterior capsule should be considered for longer eyes, as it is protective against decentration.

  20. Comparison of contact lens and intraocular lens correction of monocular aphakia during infancy: a randomized clinical trial of HOTV optotype acuity at age 4.5 years and clinical findings at age 5 years.

    PubMed

    Lambert, Scott R; Lynn, Michael J; Hartmann, E Eugenie; DuBois, Lindreth; Drews-Botsch, Carolyn; Freedman, Sharon F; Plager, David A; Buckley, Edward G; Wilson, M Edward

    2014-06-01

    The efficacy and safety of primary intraocular lens (IOL) implantation during early infancy is unknown. To compare the visual outcomes of patients optically corrected with contact lenses vs IOLs following unilateral cataract surgery during early infancy. The Infant Aphakia Treatment Study is a randomized clinical trial with 5 years of follow-up that involved 114 infants with unilateral congenital cataracts at 12 sites. A traveling examiner assessed visual acuity at age 4.5 years. Cataract surgery with or without primary IOL implantation. Contact lenses were used to correct aphakia in patients who did not receive IOLs. Treatment was determined through random assignment. HOTV optotype visual acuity at 4.5 years of age. The median logMAR visual acuity was not significantly different between the treated eyes in the 2 treatment groups (both, 0.90 [20/159]; P = .54). About 50% of treated eyes in both groups had visual acuity less than or equal to 20/200. Significantly more patients in the IOL group had at least 1 adverse event after cataract surgery (contact lens, 56%; IOL, 81%; P = .02). The most common adverse events in the IOL group were lens reproliferation into the visual axis, pupillary membranes, and corectopia. Glaucoma/glaucoma suspect occurred in 35% of treated eyes in the contact lens group vs 28% of eyes in the IOL group (P = .55). Since the initial cataract surgery, significantly more patients in the IOL group have had at least 1 additional intraocular surgery (contact lens, 21%; IOL, 72%; P < .001). There was no significant difference between the median visual acuity of operated eyes in children who underwent primary IOL implantation and those left aphakic. However, there were significantly more adverse events and additional intraoperative procedures in the IOL group. When operating on an infant younger than 7 months of age with a unilateral cataract, we recommend leaving the eye aphakic and focusing the eye with a contact lens. Primary IOL

  1. Assessment of tilt and decentration of crystalline lens and intraocular lens relative to the corneal topographic axis using anterior segment optical coherence tomography

    PubMed Central

    Morizane, Yuki; Shiode, Yusuke; Hirano, Masayuki; Doi, Shinichiro; Toshima, Shinji; Fujiwara, Atsushi; Shiraga, Fumio

    2017-01-01

    Purpose To investigate the tilt and decentration of the crystalline lens and the intraocular lens (IOL) relative to the corneal topographic axis using anterior segment ocular coherence tomography (AS-OCT). Methods A sample set of 100 eyes from 49 subjects (41 eyes with crystalline lenses and 59 eyes with IOLs) were imaged using second generation AS-OCT (CASIA2, TOMEY) in June and July 2016 at Okayama University. Both mydriatic and non-mydriatic images were obtained, and the tilt and decentration of the crystalline lens and the IOL were quantified. The effects of pupil dilation on measurements were also assessed. Results The crystalline lens showed an average tilt of 5.15° towards the inferotemporal direction relative to the corneal topographic axis under non-mydriatic conditions and 5.25° under mydriatic conditions. Additionally, an average decentration of 0.11 mm towards the temporal direction was observed under non-mydriatic conditions and 0.08 mm under mydriatic conditions. The average tilt for the IOL was 4.31° towards the inferotemporal direction relative to the corneal topographic axis under non-mydriatic conditions and 4.65° in the same direction under mydriatic conditions. The average decentration was 0.05 mm towards the temporal direction under non-mydriatic conditions and 0.08 mm in the same direction under mydriatic conditions. A strong correlation was found between the average tilt and decentration values of the crystalline lens and the IOL under both non-mydriatic and mydriatic conditions (all Spearman correlation coefficients, r ≥ 0.800; all P < 0.001). Conclusion When measured using second generation AS-OCT, both the crystalline lens and the IOL showed an average tilt of 4–6° toward the inferotemporal direction relative to the corneal topographic axis and an average decentration of less than 0.12 mm towards the temporal direction. These results were not influenced by pupil dilation and they showed good repeatability. PMID:28863141

  2. Assessment of tilt and decentration of crystalline lens and intraocular lens relative to the corneal topographic axis using anterior segment optical coherence tomography.

    PubMed

    Kimura, Shuhei; Morizane, Yuki; Shiode, Yusuke; Hirano, Masayuki; Doi, Shinichiro; Toshima, Shinji; Fujiwara, Atsushi; Shiraga, Fumio

    2017-01-01

    To investigate the tilt and decentration of the crystalline lens and the intraocular lens (IOL) relative to the corneal topographic axis using anterior segment ocular coherence tomography (AS-OCT). A sample set of 100 eyes from 49 subjects (41 eyes with crystalline lenses and 59 eyes with IOLs) were imaged using second generation AS-OCT (CASIA2, TOMEY) in June and July 2016 at Okayama University. Both mydriatic and non-mydriatic images were obtained, and the tilt and decentration of the crystalline lens and the IOL were quantified. The effects of pupil dilation on measurements were also assessed. The crystalline lens showed an average tilt of 5.15° towards the inferotemporal direction relative to the corneal topographic axis under non-mydriatic conditions and 5.25° under mydriatic conditions. Additionally, an average decentration of 0.11 mm towards the temporal direction was observed under non-mydriatic conditions and 0.08 mm under mydriatic conditions. The average tilt for the IOL was 4.31° towards the inferotemporal direction relative to the corneal topographic axis under non-mydriatic conditions and 4.65° in the same direction under mydriatic conditions. The average decentration was 0.05 mm towards the temporal direction under non-mydriatic conditions and 0.08 mm in the same direction under mydriatic conditions. A strong correlation was found between the average tilt and decentration values of the crystalline lens and the IOL under both non-mydriatic and mydriatic conditions (all Spearman correlation coefficients, r ≥ 0.800; all P < 0.001). When measured using second generation AS-OCT, both the crystalline lens and the IOL showed an average tilt of 4-6° toward the inferotemporal direction relative to the corneal topographic axis and an average decentration of less than 0.12 mm towards the temporal direction. These results were not influenced by pupil dilation and they showed good repeatability.

  3. Scanning electron microscopy analysis of a sputnik-like intraocular lens 28 years after implantation.

    PubMed

    Ferrer, Consuelo; Abu-Mustafa, Sabat K; Alió, Jorge L

    2009-09-01

    To report a pupil-supported, iris-clip intraocular lens (IOL) that was explanted more than 28 years after implantation. A pupil-supported, iris-clip, Sputnik-like IOL was implanted in the left eye of a 33-year-old man to correct aphakia after extracapsular cataract extraction due to trauma. Twenty-eight years after implantation, the patient was referred to our center with loss of vision. Clinical examination showed dislocation of the IOL, which was subsequently explanted. Scanning electron microscopic examination showed a transparent, polymethylmethacrylate (PMMA), pupil-supported, iris-clip IOL with melanosomes and cell deposits (foreign-body reaction) on its surface. This case demonstrates the inertness of PMMA material and reports that a foreign body reaction can be induced following IOL dislocation 28 years after implantation. Copyright 2009, SLACK Incorporated.

  4. Comparative study of induced changes in effective lens position and refraction after Nd:YAG laser capsulotomy according to intraocular lens design.

    PubMed

    Monteiro, Tiago; Soares, Andreia; Leite, Ricardo Dourado; Franqueira, Nuno; Faria-Correia, Fernando; Vaz, Fernando

    2018-01-01

    To evaluate and compare the changes in refraction and effective intraocular lens (IOL) position between a plate-haptic IOL and a c-loop single-piece IOL after neodymium-doped yttrium aluminium garnet (YAG) laser posterior capsulotomy. In a prospective study, anterior chamber depth and subjective refraction were measured in 110 pseudophakic eyes from 110 patients, before and 1 month after YAG laser capsulotomy. Patients were divided into 2 groups according to the IOL design: group 1 (plate-haptic acrylic hydrophilic AT LISA tri 839MP ® ) and group 2 (c-loop acrylic hydrophobic single-piece AcrySof ® SA60AT). Lens position was obtained through optical coherence biometry (Biograph WaveLight OB820 ® ). YAG laser capsulotomy was performed 37.8±9.8 months after surgery in group 1 and 40.6±8.6 months in group 2 ( p =0.125). Significant changes were found in the lens effective position after treatment in the 2 groups. The YAG posterior capsulotomy led to a change of anterior chamber depth in group 1 from 4.03±0.32 mm to 3.86±0.34 mm ( p =0.02) and in group 2 from 4.03±0.37 mm to 4.14±0.45 mm ( p =0.025). After YAG laser posterior capsulotomy, no significant changes were observed in mean spherical equivalent, sphere or cylinder for both groups ( p >0.05). YAG laser posterior capsulotomy can induce a significant change in the IOL position according to the IOL type; however, the refractive change after treatment is clinically insignificant.

  5. New trends in intraocular lens imaging

    NASA Astrophysics Data System (ADS)

    Millán, María S.; Alba-Bueno, Francisco; Vega, Fidel

    2011-08-01

    As a result of modern technological advances, cataract surgery can be seen as not only a rehabilitative operation, but a customized procedure to compensate for important sources of image degradation in the visual system of a patient, such as defocus and some aberrations. With the development of new materials, instruments and surgical techniques in ophthalmology, great progress has been achieved in the imaging capability of a pseudophakic eye implanted with an intraocular lens (IOL). From the very beginning, optical design has played an essential role in this progress. New IOL designs need, on the one hand, theoretical eye models able to predict optical imaging performance and on the other hand, testing methods, verification through in vitro and in vivo measurements, and clinical validation. The implant of an IOL requires a precise biometry of the eye, a prior calculation from physiological data, and an accurate position inside the eye. Otherwise, the effects of IOL calculation errors or misplacements degrade the image very quickly. The incorporation of wavefront aberrometry into clinical ophthalmology practice has motivated new designs of IOLs to compensate for high order aberrations in some extent. Thus, for instance, IOLs with an aspheric design have the potential to improve optical performance and contrast sensitivity by reducing the positive spherical aberration of human cornea. Monofocal IOLs cause a complete loss of accommodation that requires further correction for either distance or near vision. Multifocal IOLs address this limitation using the principle of simultaneous vision. Some multifocal IOLs include a diffractive zone that covers the aperture in part or totally. Reduced image contrast and undesired visual phenomena, such as halos and glare, have been associated to the performance of multifocal IOLs. Based on a different principle, accommodating IOLs rely on the effort of the ciliary body to increase the effective power of the optical system of the

  6. CUSTOM OPTIMIZATION OF INTRAOCULAR LENS ASPHERICITY

    PubMed Central

    Koch, Douglas D.; Wang, Li

    2007-01-01

    Purpose To investigate the optimal amount of ocular spherical aberration (SA) in an intraocular lens (IOL) to maximize optical quality. Methods In 154 eyes of 94 patients aged 40 to 80 years, implantation of aspheric IOLs was simulated with different amounts of SA to produce residual ocular SA from −0.30 μm to +0.30 μm. Using the VOL-CT program (Sarver & Associates, Carbondale, Illinois), corneal wavefront aberrations up to 6th order were computed from corneal topographic elevation data (Humphrey Atlas, Carl Zeiss Meditec, Inc, Dublin, California). Using the ZernikeTool program (Advanced Medical Optics, Inc, Santa Ana, California), the polychromatic point spread function with Stiles-Crawford effect was calculated for the residual ocular higher-order aberrations (HOAs, 3rd to 6th order, 6-mm pupil), assuming fully corrected 2nd-order aberrations. Five parameters were used to quantify optical image quality, and we determined the residual ocular SA at which the maximal image quality was achieved for each eye. Stepwise multiple regression analysis was performed to assess the predictors for optimal SA of each eye. Results The optimal SA varied widely among eyes. Most eyes had best image quality with low amounts of negative SA. For modulation transfer function volume up to 15 cycles/degree, the amount of optimal SA could be predicted based on other HOAs of the cornea with coefficient of multiple determination (R2) of 79%. Eight Zernike terms significantly contributed to the optimal SA in this model; the order of importance to optimal SA from most to least was: Z60, Z62, Z42, Z53, Z64, Z3−1, Z33, and Z31. For the other 4 measures of visual quality, the coefficients of determination varied from 32% to 63%. Conclusion The amount of ocular SA producing best image quality varied widely among subjects and could be predicted based on corneal HOAs. Selection of an aspheric IOL should be customized according to the full spectrum of corneal HOAs and not 4th-order SA alone

  7. Scheimpflug camera combined with placido-disk corneal topography and optical biometry for intraocular lens power calculation.

    PubMed

    Kirgiz, Ahmet; Atalay, Kurşat; Kaldirim, Havva; Cabuk, Kubra Serefoglu; Akdemir, Mehmet Orcun; Taskapili, Muhittin

    2017-08-01

    The purpose of this study was to compare the keratometry (K) values obtained by the Scheimpflug camera combined with placido-disk corneal topography (Sirius) and optical biometry (Lenstar) for intraocular lens (IOL) power calculation before the cataract surgery, and to evaluate the accuracy of postoperative refraction. 50 eyes of 40 patients were scheduled to have phacoemulsification with the implantation of a posterior chamber intraocular lens. The IOL power was calculated using the SRK/T formula with Lenstar K and K readings from Sirius. Simulated K (SimK), K at 3-, 5-, and 7-mm zones from Sirius were compared with Lenstar K readings. The accuracy of these parameters was determined by calculating the mean absolute error (MAE). The mean Lenstar K value was 44.05 diopters (D) ±1.93 (SD) and SimK, K at 3-, 5-, and 7-mm zones were 43.85 ± 1.91, 43.88 ± 1.9, 43.84 ± 1.9, 43.66 ± 1.85 D, respectively. There was no statistically significant difference between the K readings (P = 0.901). When Lenstar was used for the corneal power measurements, MAE was 0.42 ± 0.33 D, but when simK of Sirius was used, it was 0.37 ± 0.32 D (the lowest MAE (0.36 ± 0.32 D) was achieved as a result of 5 mm K measurement), but it was not statistically significant (P = 0.892). Of all the K readings of Sirius and Lenstar, Sirius 5-mm zone K readings were the best in predicting a more precise IOL power. The corneal power measurements with the Scheimpflug camera combined with placido-disk corneal topography can be safely used for IOL power calculation.

  8. Stability and safety of MA50 intraocular lens placed in the sulcus

    PubMed Central

    Kemp, P S; Oetting, T A

    2015-01-01

    Purpose To describe the safety and stability of sulcus placement of the MA50 intraocular lens (IOL). Patients and methods Consecutive patients with MA50 IOLs placed in the sulcus at the University of Iowa Hospitals and Clinics, Iowa City, Iowa, USA, from 1997 to 2012 were identified. Inclusion criteria included patients with over 4 weeks of follow-up data. AEL was compared with incidence of IOL decentration using at two-tailed Student's t-test. Results Fifty eyes of 49 patients meeting the inclusion criteria were identified. Four weeks post-operatively, the average best-corrected visual acuity was 20/30. IOL decentration occurred in 14% of patients; patients with decentered IOLs had a significantly longer average AEL (25.37 mm) than patients whose IOL remained centered (23.94 mm, P=0.017). Other complications included uveitis-glaucoma-hyphema syndrome (12%), iritis (8%), and glaucoma (6%). There were no cases of pigment dispersion syndrome or need for lens exchange. Twelve eyes (24%) had intra-operative optic capture by the anterior capsule, none of which had post-operative decentration. Conclusion The MA50 IOL is a reasonable, stable option for placement in the sulcus, with a low-risk profile; however, in eyes with longer AEL and presumably larger anterior segment, surgeons should consider placing an IOL with longer haptic distance than the MA50 to maintain centration. Optic capture of the MA50 IOL by the anterior capsule should be considered for longer eyes, as it is protective against decentration. PMID:26139047

  9. Luneburg lens and optical matrix algebra research

    NASA Technical Reports Server (NTRS)

    Wood, V. E.; Busch, J. R.; Verber, C. M.; Caulfield, H. J.

    1984-01-01

    Planar, as opposed to channelized, integrated optical circuits (IOCs) were stressed as the basis for computational devices. Both fully-parallel and systolic architectures are considered and the tradeoffs between the two device types are discussed. The Kalman filter approach is a most important computational method for many NASA problems. This approach to deriving a best-fit estimate for the state vector describing a large system leads to matrix sizes which are beyond the predicted capacities of planar IOCs. This problem is overcome by matrix partitioning, and several architectures for accomplishing this are described. The Luneburg lens work has involved development of lens design techniques, design of mask arrangements for producing lenses of desired shape, investigation of optical and chemical properties of arsenic trisulfide films, deposition of lenses both by thermal evaporation and by RF sputtering, optical testing of these lenses, modification of lens properties through ultraviolet irradiation, and comparison of measured lens properties with those expected from ray trace analyses.

  10. Comparative study of induced changes in effective lens position and refraction after Nd:YAG laser capsulotomy according to intraocular lens design

    PubMed Central

    Monteiro, Tiago; Soares, Andreia; Leite, Ricardo Dourado; Franqueira, Nuno; Faria-Correia, Fernando; Vaz, Fernando

    2018-01-01

    Purpose To evaluate and compare the changes in refraction and effective intraocular lens (IOL) position between a plate-haptic IOL and a c-loop single-piece IOL after neodymium-doped yttrium aluminium garnet (YAG) laser posterior capsulotomy. Methods In a prospective study, anterior chamber depth and subjective refraction were measured in 110 pseudophakic eyes from 110 patients, before and 1 month after YAG laser capsulotomy. Patients were divided into 2 groups according to the IOL design: group 1 (plate-haptic acrylic hydrophilic AT LISA tri 839MP®) and group 2 (c-loop acrylic hydrophobic single-piece AcrySof® SA60AT). Lens position was obtained through optical coherence biometry (Biograph WaveLight OB820®). Results YAG laser capsulotomy was performed 37.8±9.8 months after surgery in group 1 and 40.6±8.6 months in group 2 (p=0.125). Significant changes were found in the lens effective position after treatment in the 2 groups. The YAG posterior capsulotomy led to a change of anterior chamber depth in group 1 from 4.03±0.32 mm to 3.86±0.34 mm (p=0.02) and in group 2 from 4.03±0.37 mm to 4.14±0.45 mm (p=0.025). After YAG laser posterior capsulotomy, no significant changes were observed in mean spherical equivalent, sphere or cylinder for both groups (p>0.05). Conclusion YAG laser posterior capsulotomy can induce a significant change in the IOL position according to the IOL type; however, the refractive change after treatment is clinically insignificant. PMID:29593378

  11. Cyclodextrin-containing hydrogels as an intraocular lens for sustained drug release

    PubMed Central

    Li, Xiao; Zhao, Yang; Wang, Kaijie; Yang, Xiaohui; Zhu, Siquan

    2017-01-01

    To improve the efficacy of anti-inflammatory factors in patients who undergo cataract surgery, poly(2-hydroxyethyl methacrylate-co-methyl methacrylate) (p(HEMA-co-MMA)) hydrogels containing β-cyclodextrin (β-CD) (pHEMA/MMA/β-CD) were designed and prepared as intraocular lens (IOLs) biomaterials that could be loaded with and achieve the sustained release of dexamethasone. A series of pHEMA/MMA/β-CD copolymers containing different ratios of β-CD (range, 2.77 to 10.24 wt.%) were obtained using thermal polymerization. The polymers had high transmittance at visible wavelengths and good biocompatibility with mouse connective tissue fibroblasts. Drug loading and release studies demonstrated that introducing β-CD into hydrogels increased loading efficiency and achieved the sustained release of the drug. Administering β-CD via hydrogels increased the equilibrium swelling ratio, elastic modulus and tensile strength. In addition, β-CD increased the hydrophilicity of the hydrogels, resulting in a lower water contact angle and higher cellular adhesion to the hydrogels. In summary, pHEMA/MMA/β-CD hydrogels show great potential as IOL biomaterials that are capable of maintaining the sustained release of anti-inflammatory drugs after cataract surgery. PMID:29244868

  12. Capsular Outcomes After Pediatric Cataract Surgery Without Intraocular Lens Implantation: Qualitative Classification and Quantitative Measurement.

    PubMed

    Tan, Xuhua; Lin, Haotian; Lin, Zhuoling; Chen, Jingjing; Tang, Xiangchen; Luo, Lixia; Chen, Weirong; Liu, Yizhi

    2016-03-01

    The objective of this study was to investigate capsular outcomes 12 months after pediatric cataract surgery without intraocular lens implantation via qualitative classification and quantitative measurement.This study is a cross-sectional study that was approved by the institutional review board of Zhongshan Ophthalmic Center of Sun Yat-sen University in Guangzhou, China.Digital coaxial retro-illumination photographs of 329 aphakic pediatric eyes were obtained 12 months after pediatric cataract surgery without intraocular lens implantation. Capsule digital coaxial retro-illumination photographs were divided as follows: anterior capsule opening area (ACOA), posterior capsule opening area (PCOA), and posterior capsule opening opacity (PCOO). Capsular outcomes were qualitatively classified into 3 types based on the PCOO: Type I-capsule with mild opacification but no invasion into the capsule opening; Type II-capsule with moderate opacification accompanied by contraction of the ACOA and invasion to the occluding part of the PCOA; and Type III-capsule with severe opacification accompanied by total occlusion of the PCOA. Software was developed to quantitatively measure the ACOA, PCOA, and PCOO using standardized DCRPs. The relationships between the accurate intraoperative anterior and posterior capsulorhexis sizes and the qualitative capsular types were statistically analyzed.The DCRPs of 315 aphakic eyes (95.8%) of 191 children were included. Capsular outcomes were classified into 3 types: Type I-120 eyes (38.1%); Type II-157 eyes (49.8%); Type III-38 eyes (12.1%). The scores of the capsular outcomes were negatively correlated with intraoperative anterior capsulorhexis size (R = -0.572, P < 0.001), but no significant correlation with intraoperative posterior capsulorhexis size (R = -0.16, P = 0.122) was observed. The ACOA significantly decreased from Type I to Type II to Type III, the PCOA increased in size from Type I to Type II, and the PCOO increased

  13. Rotation stability of a toric intraocular lens with a second capsular tension ring.

    PubMed

    Sagiv, Oded; Sachs, Dan

    2015-05-01

    An Acrysof toric intraocular lens (IOL) and a capsular tension ring (CTR) were implanted in the highly myopic eye of a 74-year-old white man during cataract surgery. On the first postoperative day, the IOL was found 90 degrees from the required position, with a consequent high amount of astigmatism. A second procedure was performed and because it was not possible to secure the toric IOL in the correct position, an additional in-the-bag CTR was inserted, with an immediate optimal outcome. The IOL remained stable up to the final follow-up examination. Co-implantation of a toric IOL and a single CTR has been reported. In our case, 2 CTRs were required to fixate the toric IOL in the correct position. This procedure is simple and safe and should be considered in cases of postoperatively misaligned toric IOLs. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  14. [Miyake-Apple video analysis of movement patterns of an accommodative intraocular lens implant].

    PubMed

    Auffarth, G U; Schmidbauer, J; Becker, K A; Rabsilber, T M; Apple, D J

    2002-11-01

    The potentially accommodative intraocular lens (IOL) is a new development in IOL design We evaluated the new Humanoptics 1CU accommodative IOL in a laboratory study with human post mortem autopsy eyes. Using the Miyake-Apple posterior view video technique, the movement pattern of the IOL was tested and observed from the posterior perspective. RESULTS. A circular bend at the level of the ciliary body applied slight circular force onto the sclera allowing the relaxation of the zonules. The shift of focus was demonstrated by using a reading target. In addition, viscoelastic was injected into the vitreous resulting in the same anterior movement of the IOL optic. The 1CU Humanoptics accommodative IOL showed potential accommodative behaviour in the laboratory. The accommodative (respectively pseudoaccommodative) effect was based on the anterior shift principle with anterior movement of the IOL-optic in the state of relaxing zonules. Whether this reflects the clinical situation, especially to this extent, must be further evaluated.

  15. The development of a tunable, single-frequency ultraviolet laser source for UV filtered Rayleigh scattering

    NASA Technical Reports Server (NTRS)

    Finkelstein, N.; Gambogi, J.; Lempert, Walter R.; Miles, Richard B.; Rines, G. A.; Finch, A.; Schwarz, R. A.

    1995-01-01

    We present the development of a flexible, high power, narrow line width, tunable ultraviolet source for diagnostic application. By frequency tripling the output of a pulsed titanium-sapphire laser, we achieve broadly tunable (227-360 nm) ultraviolet light with high quality spatial and spectral resolution. We also present the characterization of a mercury vapor cell which provides a narrow band, sharp edge absorption filter at 253.7 nm. These two components form the basis for the extension of the Filtered Rayleigh Scattering technique into the ultraviolet. The UV-FRS system is comprised of four pieces: a single frequency, cw tunable Ti:Sapphire seeding source; a high-powered pulsed Ti:Sapphire oscillator; a third harmonic generator system; and an atomic mercury vapor filter. In this paper we discuss the development and characterization of each of these elements.

  16. Advantages of using newly developed quartz contact lens with slit illumination from operating microscope.

    PubMed

    Kiyokawa, Masatoshi; Sakuma, Toshiro; Hatano, Noriko; Mizota, Atsushi; Tanaka, Minoru

    2009-06-01

    The purpose of this article is to report the characteristics and advantages of using a newly designed quartz contact lens with slit illumination from an operating microscope for intraocular surgery. The new contact lens is made of quartz. The lens is convex-concave and is used in combination with slit illumination from an operating microscope. The optical properties of quartz make this lens less reflective with greater transmittance. The combination of a quartz contact lens with slit illumination provided a brighter and wider field of view than conventional lenses. This system enabled us to perform bimanual vitrectomy and scleral buckling surgery without indirect ophthalmoscope. Small intraocular structures in the posterior pole or in the periphery were detected more easily. In conclusion, the newly designed quartz lens with slit beam illumination from an operating microscope provided a bright, clear and wide surgical field, and allowed intraocular surgery to be performed more easily.

  17. Pigment dispersion glaucoma induced by the chafing effect of intraocular lens haptics in Asian eyes.

    PubMed

    Hong, Ying; Sun, Yan-Xiu; Qi, Hong; Zhou, Ji-Chao; Hao, Yan-Sheng

    2013-03-01

    To study the possible mechanism and treatment for pigment dispersion glaucoma (PDG) caused by single-piece acrylic (SPA) intraocular lens (IOL) ciliary sulcus fixation in Asian eyes. Patients referred for PDG caused by SPA IOL ciliary sulcus fixation to our hospital from April 2005 to June 2011 were included. The patients' general information, IOL type, interval between initial surgery and PDG occurrence, examination findings, antiglaucoma medicine regimen and surgical interventions were recorded. In total, six eyes from five Chinese patients were included in this study. The intraocular pressure (IOP) increased 19-30 days after cataract surgery and was not satisfactorily controlled with antiglaucoma medication. Dense pigmentation was deposited on the IOLs and on the anterior chamber angle. IOL haptic chafing was noted on the rear iris surface. IOL repositioning in the capsular bag was performed in three eyes and was combined with trabeculectomy in two eyes with progressive glaucoma. An IOL exchange with three-piece IOL ciliary sulcus fixation was performed in the other three eyes. Scanning electron microscopy of the explanted IOLs demonstrated a rough edge on the IOL haptics. SPA IOLs were not suitable for ciliary sulcus fixation. The chafing effect of the IOL haptics on the posterior iris pigment epithelium could induce PDG in Asian eyes. IOLs should be positioned in the capsular bag or a three-piece IOL should be used instead.

  18. Bilateral reading performance of 4 multifocal intraocular lens models and a monofocal intraocular lens under bright lighting conditions.

    PubMed

    Rasp, Max; Bachernegg, Alexander; Seyeddain, Orang; Ruckhofer, Josef; Emesz, Martin; Stoiber, Josef; Grabner, Günther; Dexl, Alois K

    2012-11-01

    To compare changes in reading performance parameters after implantation of 4 multifocal intraocular lens (IOL) models and a monofocal IOL. Department of Ophthalmology, Paracelsus Medical University, Salzburg, Austria. Prospective randomized controlled clinical trial. Patients with bilateral cataract without additional ocular pathology were scheduled for bilateral implantation of Acri.Smart 48S monofocal, Acrysof Restor SN6AD3 apodized multifocal, AT LISA 366D diffractive multifocal, Tecnis ZMA00 diffractive multifocal, or Rezoom refractive multifocal IOLs. Bilateral corrected and uncorrected reading acuity, reading distance, mean and maximum reading speeds, and smallest log-scaled print size of a Radner reading chart were evaluated under bright lighting conditions (500 lux) using the Salzburg Reading Desk. Pupil size was not measured throughout the trial. The minimum follow-up was 12 months. The diffractive multifocal groups had significantly better uncorrected reading acuity and uncorrected smallest print size than the monofocal and refractive multifocal groups 1, 6, and 12 months postoperatively. The diffractive IOL groups had comparable uncorrected reading distance of approximately 32 cm, which was larger in the monofocal group (38.9 ± 8.4 cm) and refractive multifocal group (37.1 ± 7.3 cm) at the last visit. Patients with diffractive IOLs could read print sizes of approximately 0.74 to 0.87 mm, which was much better than in the monofocal and refractive multifocal groups. The diffractive AT LISA IOL provided the best reading speed values (mean and maximum, corrected and uncorrected). Multifocal IOLs with a diffractive component provided good reading performance that was significantly better than that obtained with a refractive multifocal or monofocal IOL. Drs. Grabner and Dexl were patent owners of the Salzburg Reading Desk technology (now owned by SRD-Vision, LLC). No other author has a financial or proprietary interest in any material or method mentioned

  19. The impact of a preloaded intraocular lens delivery system on operating room efficiency in routine cataract surgery.

    PubMed

    Jones, Jason J; Chu, Jeffrey; Graham, Jacob; Zaluski, Serge; Rocha, Guillermo

    2016-01-01

    The aim of this study was to evaluate the operational impact of using preloaded intraocular lens (IOL) delivery systems compared with manually loaded IOL delivery processes during routine cataract surgeries. Time and motion data, staff and surgery schedules, and cost accounting reports were collected across three sites located in the US, France, and Canada. Time and motion data were collected for manually loaded IOL processes and preloaded IOL delivery systems over four surgery days. Staff and surgery schedules and cost accounting reports were collected during the 2 months prior and after introduction of the preloaded IOL delivery system. The study included a total of 154 routine cataract surgeries across all three sites. Of these, 77 surgeries were performed using a preloaded IOL delivery system, and the remaining 77 surgeries were performed using a manual IOL delivery process. Across all three sites, use of the preloaded IOL delivery system significantly decreased mean total case time by 6.2%-12.0% (P<0.001 for data from Canada and the US and P<0.05 for data from France). Use of the preloaded delivery system also decreased surgeon lens time, surgeon delays, and eliminated lens touches during IOL preparation. Compared to a manual IOL delivery process, use of a preloaded IOL delivery system for cataract surgery reduced total case time, total surgeon lens time, surgeon delays, and eliminated IOL touches. The time savings provided by the preloaded IOL delivery system provide an opportunity for sites to improve routine cataract surgery throughput without impacting surgeon or staff capacity.

  20. The rectenna design on contact lens for wireless powering of the active intraocular pressure monitoring system.

    PubMed

    Cheng, H W; Jeng, B M; Chen, C Y; Huang, H Y; Chiou, J C; Luo, C H

    2013-01-01

    This paper proposed a wireless power harvesting system with micro-electro-mechanical-systems (MEMS) fabrication for noninvasive intraocular pressure (IOP) measurement on soft contact lens substructure. The power harvesting IC consists of a loop antenna, an impedance matching network and a rectifier. The proposed IC has been designed and fabricated by CMOS 0.18 um process that operates at the ISM band of 5.8 GHz. The antenna and the power harvesting IC would be bonded together by using flip chip bonding technologies without extra wire interference. The circuit utilized an impedance transformation circuit to boost the input RF signal that improves the circuit performance. The proposed design achieves an RF-to-DC conversion efficiency of 35% at 5.8 GHz.

  1. Binocular function to increase visual outcome in patients implanted with a diffractive trifocal intraocular lens.

    PubMed

    Kretz, Florian T A; Müller, Matthias; Gerl, Matthias; Gerl, Ralf H; Auffarth, Gerd U

    2015-08-21

    To evaluate binocular visual outcome for near, intermediate and distance compared to monocular visual outcome at the same distances in patients implanted with a diffractive trifocal intraocular lens (IOL). The study comprised of 100 eyes of 50 patients that underwent bilateral refractive lens exchange or cataract surgery with implantation of a multifocal diffractive IOL (AT LISA tri 839MP, Carl Zeiss Meditech, Germany). A complete ophthalmological examination was performed preoperatively and 3 month postoperatively. The main outcome measures were monocular and binocular uncorrected distance (UDVA), corrected distance (CDVA), uncorrected intermediate (UIVA), and uncorrected near visual acuities (UNVA), keratometry, and manifest refraction. The mean age was 59.28 years ± 9.6 [SD] (range 44-79 years), repectively. There was significant improvement in UDVA, UIVA, UNVA and CDVA. Comparing the monocular results to the binocular results there was a statistical significant better binocular outcome in all distances (UDVA p = 0.036; UIVA p < 0.0001; UNVA p = 0.001). The postoperative manifest refraction was in 86 % of patients within ± 0.50 [D]. The trifocal IOL improved near, intermediate, and distance vision compared to preoperatively. In addition a statistical significant increase for binocular visual function in all distances could be found. German Clinical Trials Register (DRKS) DRKS00007837.

  2. Pentacam Scheimpflug quantitative imaging of the crystalline lens and intraocular lens.

    PubMed

    Rosales, Patricia; Marcos, Susana

    2009-05-01

    To implement geometrical and optical distortion correction methods for anterior segment Scheimpflug images obtained with a commercially available system (Pentacam, Oculus Optikgeräte GmbH). Ray tracing algorithms were implemented to obtain corrected ocular surface geometry from the original images captured by the Pentacam's CCD camera. As details of the optical layout were not fully provided by the manufacturer, an iterative procedure (based on imaging of calibrated spheres) was developed to estimate the camera lens specifications. The correction procedure was tested on Scheimpflug images of a physical water cell model eye (with polymethylmethacrylate cornea and a commercial IOL of known dimensions) and of a normal human eye previously measured with a corrected optical and geometrical distortion Scheimpflug camera (Topcon SL-45 [Topcon Medical Systems Inc] from the Vrije University, Amsterdam, Holland). Uncorrected Scheimpflug images show flatter surfaces and thinner lenses than in reality. The application of geometrical and optical distortion correction algorithms improves the accuracy of the estimated anterior lens radii of curvature by 30% to 40% and of the estimated posterior lens by 50% to 100%. The average error in the retrieved radii was 0.37 and 0.46 mm for the anterior and posterior lens radii of curvature, respectively, and 0.048 mm for lens thickness. The Pentacam Scheimpflug system can be used to obtain quantitative information on the geometry of the crystalline lens, provided that geometrical and optical distortion correction algorithms are applied, within the accuracy of state-of-the art phakometry and biometry. The techniques could improve with exact knowledge of the technical specifications of the instrument, improved edge detection algorithms, consideration of aspheric and non-rotationally symmetrical surfaces, and introduction of a crystalline gradient index.

  3. Management of moderate and severe corneal astigmatism with AcrySof® toric intraocular lens implantation – Our experience

    PubMed Central

    Farooqui, Javed Hussain; Koul, Archana; Dutta, Ranjan; Shroff, Noshir Minoo

    2015-01-01

    Purpose Visual performance following toric intraocular lens implantation for cataract with moderate and severe astigmatism. Setting Cataract services, Shroff Eye Centre, New Delhi, India. Design Case series. Method This prospective study included 64 eyes of 40 patients with more than 1.50 dioptre (D) of pre-existing corneal astigmatism undergoing phacoemulsification with implantation of the AcrySof® toric IntraOcular Lens (IOL). The unaided visual acuity (UCVA), best corrected visual acuity (BCVA), residual refractive sphere and refractive cylinders were evaluated. Toric IOL axis and alignment error was measured by slit lamp method and Adobe Photoshop (version 7) method. Patient satisfaction was evaluated using a satisfaction questionnaire at 3 months. Results The mean residual refractive astigmatism was 0.57 D at the final follow-up of 3 months. Mean alignment error was 3.44 degrees (SD = 2.60) by slit lamp method and 3.88 degrees (SD = 2.86) by Photoshop method. Forty-six (71.9%) eyes showed misalignment of 5 degrees or less, and 60 (93.8%) eyes showed misalignment of 10 degrees or less. The mean log MAR UCVA at 1st post-op day was 0.172 (SD = 0.02), on 7th post-op day was 0.138 (SD = 0.11), and on 30th post-op day was 0.081 (SD = 0.11). The mean log MAR BCVA at three months was −0.04 (SD = 0.76). Conclusion We believe that implantation of AcrySof® toric IOL is an effective, safe and predictable method to correct high amounts of corneal astigmatism during cataract surgery. PMID:26586976

  4. Customized ultra-high-power toric intraocular lens implantation for pellucid marginal degeneration and cataract.

    PubMed

    Luck, Jonathan

    2010-07-01

    I report a case of pellucid marginal degeneration (PMD) with cataract that was successfully treated with implantation of an ultra-high-power customized bitoric AT.Comfort 646TLC intraocular lens (IOL). The preoperative uncorrected distance visual acuity (UDVA) was 6/120 and the corrected distance visual acuity (CDVA), 6/24 with 10.9 diopters (D) of keratometric astigmatism on Scheimpflug imaging. After implantation of an IOL with -0.5 +16.0 x 170, the UDVA was 6/9 with a manifest refraction of +0.25 +1.25 x 150 and the CDVA, 6/6(-1). No surgical complications or postoperative problems occurred, and the patient was very satisfied with the outcome. A longer follow-up is required to confirm this favorable clinical result. The author has no financial or proprietary interest in any material or method mentioned. Copyright 2010 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  5. Implantation of a Multifocal Toric Intraocular Lens after Radial Keratotomy and Cross-Linking with Hyperopia and Astigmatism Residues: A Case Report.

    PubMed

    Nuzzi, Raffaele; Monteu, Francesca; Tridico, Federico

    2017-01-01

    Radial keratotomy is a refractive surgical technique, widely used in the 80s and early 90s to correct myopia and astigmatism, but now overcome by more recent laser techniques. Important consequences, often in patients with more than 45 years of age, are progressive hyperopic shift and/or an increase in corneal astigmatism, whose main cause seems to be an increase in the curvature radius of the central portion of the cornea. This seems to be due to radial keratotomy incisions - with the consequent need for cross-linking - intraocular pressure, and corneal biomechanical parameters. The authors propose phacoemulsification with a customized multifocal toric intraocular lens implantation to correct the induced shift and hyperopic astigmatism. A decent postoperative visual acuity was observed with good patient satisfaction. A specific protocol must be applied to optimize the correct diagnosis, presurgical evaluation and postsurgical outcomes that are to be maintained over time, without regressions.

  6. Intraocular lenses in age-related macular degeneration.

    PubMed

    Grzybowski, Andrzej; Wasinska-Borowiec, Weronika; Alio, Jorge L; Amat-Peral, Pedro; Tabernero, Juan

    2017-09-01

    The aim of this work is to review the lenses, assessing their advantages and disadvantages. We describe a total of seven types of intraocular lenses (IOLs) recommended for age-related macular degeneration (AMD). We used the PubMed web platform to search for implantable devices in various stages of AMD. We searched for both prospective and retrospective studies and also case reports. Clinical results in AMD patients have been described for a total of seven types of IOLs recommended for AMD: an implantable miniature telescope (IMT), IOL-VIP System, Lipshitz macular implant (LMI), sulcus-implanted Lipshitz macular implant, LMI-SI, Fresnel Prism Intraocular Lens, iolAMD and Scharioth Macula Lens. We conclude that to objectively ascertain the effectiveness and safety of these lenses, further independent clinical studies with longer follow-up data are necessary prior to the general use of these optical devices.

  7. A new surgical technique using steel suture for trans-scleral fixation of posterior chamber intraocular lenses

    PubMed Central

    Ram, Jagat; Gupta, Nishant; Chaudhary, Manish; Verma, Neelam

    2013-01-01

    Background: A new emerging complication of trans-scleral fixation of posterior chamber (PC) intraocular lens (IOL) with polypropylene suture is high rates of spontaneous dislocation of the IOL due to disintegration or breakage of suture. Materials: We report a new surgical technique of trans-scleral fixation of posterior chamber intraocular lens (SF PCIOL) with steel suture to eliminate the complication of dislocation of IOL fixed with polypropylene suture in one adult and a child. Results: We successfully achieved stable fixation and good centration of IOL after SF PCIOL with steel suture in these patient having inadequate posterior capsular support. Both eyes achieved best corrected visual acuity 20/40 at 18 months follow-up. Conclusions: Steel suture is a viable option for trans-scleral fixation of posterior chamber intraocular lens. PMID:23619504

  8. Posterior capsule opacification after implantation of a hydrogel intraocular lens

    PubMed Central

    Hayashi, K; Hayashi, H

    2004-01-01

    Aim: To compare the degree of posterior capsule opacification (PCO) in eyes with a hydrophilic hydrogel intraocular lens (IOL) with that in eyes with a hydrophobic acrylic IOL. Methods: Ninety five patients underwent a hydrogel IOL implantation in one eye and an acrylic IOL implantation in the opposite eye. The PCO value of these patients was measured using the Scheimpflug videophotography system at 1, 6, 12, 18, and 24 months postoperatively. The rate of neodymium:YAG (Nd:YAG) laser posterior capsulotomy and visual acuity were also evaluated. Results: The mean PCO value in the hydrogel group increased significantly (p<0.0001), while that in the acrylic group did not show significant change. The PCO value in the hydrogel group was significantly greater than that in the acrylic group throughout the follow up period. Kaplan-Meier survival analysis determined that the Nd:YAG capsulotomy rate in the hydrogel group was significantly higher than that in the acrylic group (p<0.0001). Mean visual acuity in the hydrogel group decreased significantly with time (p<0.0001), and became significantly worse than that in the acrylic group at 18 and 24 months postoperatively. Conclusion: Posterior capsule opacification in eyes with a hydrophilic hydrogel IOL is significantly more extensive than that in eyes with a hydrophobic acrylic IOL, and results in a significant impairment of visual acuity. PMID:14736768

  9. OPTICAL PRINCIPLES, BIOMECHANICS, AND INITIAL CLINICAL PERFORMANCE OF A DUAL-OPTIC ACCOMMODATING INTRAOCULAR LENS (AN AMERICAN OPHTHALMOLOGICAL SOCIETY THESIS)

    PubMed Central

    McLeod, Stephen D.

    2006-01-01

    Purpose To design and develop an accommodating intraocular lens (IOL) for endocapsular fixation with extended accommodative range that can be adapted to current standard extracapsular phacoemulsification technique. Methods Ray tracing analysis and lens design; finite element modeling of biomechanical properties; cadaver eye implantation; initial clinical evaluation. Results Ray tracing analysis indicated that a dual-optic design with a high plus-power front optic coupled to an optically compensatory minus posterior optic produced greater change in conjugation power of the eye compared to that produced by axial movement of a single-optic IOL, and that magnification effects were unlikely to account for improved near vision. Finite element modeling indicated that the two optics can be linked by spring-loaded haptics that allow anterior and posterior axial displacement of the front optic in response to changes in ciliary body tone and capsular tension. A dual-optic single-piece foldable silicone lens was constructed based on these principles. Subsequent initial clinical evaluation in 24 human eyes after phacoemulsification for cataract indicated mean 3.22 diopters of accommodation (range, 1 to 5 D) based on defocus curve measurement. Accommodative amplitude evaluation at 1- and 6-month follow-up in all eyes indicated that the accommodative range was maintained and that the lens was well tolerated. Conclusions A dual-optic design increases the accommodative effect of axial optic displacement, with minimal magnification effect. Initial clinical trials suggest that IOLs designed on this principle might provide true pseudophakic accommodation following cataract extraction and lens implantation. PMID:17471355

  10. Silicone intraocular lens surface calcification in a patient with asteroid hyalosis.

    PubMed

    Matsumura, Kazuhiro; Takano, Masahiko; Shimizu, Kimiya; Nemoto, Noriko

    2012-07-01

    To confirm a substance presence on the posterior intraocular lens (IOL) surface in a patient with asteroid hyalosis. An 80-year-old man had IOLs for approximately 12 years. Opacities and neodymium-doped yttrium aluminum garnet pits were observed on the posterior surface of the right IOL. Asteroid hyalosis and an epiretinal membrane were observed OD. An IOL exchange was performed on 24 March 2008, and the explanted IOL was analyzed using a light microscope and a transmission electron microscope with a scanning electron micrograph and an energy-dispersive X-ray spectrometer for elemental analysis. To confirm asteroid hyalosis, asteroid bodies were examined with the ionic liquid (EtMeIm+ BF4-) method using a field emission scanning electron microscope (FE-SEM) with digital beam control RGB mapping. X-ray spectrometry of the deposits revealed high calcium and phosphorus peaks. Spectrometry revealed that the posterior IOL surface opacity was due to a calcium-phosphorus compound. Examination of the asteroid bodies using FE-SEM with digital beam control RGB mapping confirmed calcium and phosphorus as the main components. Calcium hydrogen phosphate dihydrate deposits were probably responsible for the posterior IOL surface opacity. Furthermore, analysis of the asteroid bodies demonstrated that calcium and phosphorus were its main components.

  11. Ray-tracing analysis of intraocular lens power in situ.

    PubMed

    Olsen, Thomas; Funding, Mikkel

    2012-04-01

    To describe a method for back-solving the power of an intraocular lens (IOL) in situ based on laser biometry and ray-tracing analysis of the pseudophakic eye. University Eye Clinic, Aarhus Hospital, Aarhus, Denmark. Evaluation of diagnostic test or technology. This study comprised pseudophakic eyes with an IOL power ranging from -2.00 to +36.00 diopters (D). Preoperatively, the corneal radius was measured with conventional autokeratometry and the axial length (AL) with optical biometry. After surgery, the position of the IOL was recorded using laser interferometry. Based on the postoperative refraction and the biometric measurements, a ray-tracing analysis was performed back-solving for the power of the IOL in situ. The analysis was performed assuming pupil diameters from 0.0 to 8.0 mm with and without correction for the Stiles-Crawford effect. The study evaluated 767 pseudophakic eyes (583 patients). Assuming a 3.0 mm pupil, the mean prediction error between the labeled and the calculated IOL power (± 1 standard deviation [SD]) was -0.26 D ± 0.65 (SD) (range -2.4 to +1.8 D). The prediction error showed no bias with IOL power or with AL. The calculated IOL power depended on the assumed pupil size and the Stiles-Crawford effect. However, the latter had a modulatory effect on the prediction error for large pupil diameters (>5.0 mm) only. The optics of the pseudophakic eye can be accurately described using exact ray tracing and modern biometric techniques. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  12. Intraocular lens scaffold technique to prevent posterior capsule rupture in cases of Morgagnian cataract.

    PubMed

    Parkash, Rohit Om; Mahajan, Shruti; Parkash, Tushya Om; Nayak, Vittal

    2017-01-01

    We describe a technique for performing safe phacoemulsification of a Morgagnian cataract using the intraocular lens (IOL) scaffold. An IOL scaffold has been used in cases in which posterior capsule rupture has occurred, leaving nonemulsified nuclear pieces. The scaffold provides a barrier that prevents the nuclear fragments from falling posteriorly into the vitreous cavity. Our technique uses the IOL as a scaffold to prevent the vulnerable posterior capsule from rupturing during nuclear emulsification in Morgagnian cataract. The technique prevents rupture of the floppy posterior capsule by providing a constant support to it. The scaffold provides stable inflation of the capsular bag and prevents inadvertent emulsification. Concurrently, it prevents dehiscence of weak zonular fibers by minimizing the stress on the zonular apparatus. Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  13. Recurrent uveitis and pigment dispersion in an eye with in-the-bag acrylic foldable intraocular lens.

    PubMed

    Thakur, Monica; Bhatia, Prashant; Chandrasekhar, Garudadri; Senthil, Sirisha

    2016-02-26

    Phacoemulsification with in-the-bag intraocular lens (IOL) implantation is the standard procedure for cataract surgery. Pigment dispersion and uveitis can result when an IOL is placed in the sulcus. We report a case of a 64-year-old woman, with pigmentary glaucoma, who developed recurrent uveitis following uneventful cataract surgery and an in-the-bag hydrophobic acrylic IOL implant. Recurrent uveitis did not subside despite use of topical steroids over 3 months. Dilated examination revealed capsulophimosis with anterior dislocation of the IOL haptic. The mechanical trauma to the iris due to the displaced haptic was implicated as the cause of recurrent uveitis, which completely resolved after capsular excision and IOL repositioning. This case illustrates a rare cause of recurrent uveitis due to IOL haptic dislocation following severe capsulophimosis. 2016 BMJ Publishing Group Ltd.

  14. Retropupillary iris-claw intraocular lens for the surgical correction of aphakia in cases with microspherophakia.

    PubMed

    Fouda, Sameh Mosaad; Al Aswad, Mahmoud A; Ibrahim, Basem M; Bori, Ashraf; Mattout, Hala K

    2016-12-01

    This study aimed to evaluate the safety and efficacy of retropupillary fixation of an iris-claw intraocular lens (IOL; Verisyse polymethyl methacrylate IOL, Abbott Medical Optics [AMO], Netherlands) for the surgical correction of aphakia in microspherophakic eyes without sufficient capsular support. This was a prospective, interventional, noncomparative case series. This interventional case series comprised 17 eyes of 9 microspherophakic patients. Retropupillary fixation of the Verisyse iris-claw IOL (AMO) was performed in all cases. The surgical time was measured. Corrected distance visual acuity, astigmatism, intraocular pressure (IOP), tissue reaction, pigment dispersion, and stability of the IOL were studied 1 day, 3 days, 1 week, 2 weeks, 1 month, and 6 months postoperatively. Eight patients had familial microspherophakia and one patient had Marfan's syndrome. Eighty-two percent of the cases achieved a visual acuity of 0.3 or better. There was no significant postoperative inflammatory reaction. Transient elevation of IOP was recorded in two cases in the 1st week only. One IOL developed disengagement of one of the haptics from the iris and was successfully re-engaged. All the other IOLs were well centered and stable. The mean surgical time was 18.0 ± 4.5 min. Retropupillary fixation of an iris-claw IOL is a safe and effective procedure that provides early visual recovery. It is also a time-saving method for correcting aphakia in microspherophakic eyes without sufficient capsular support.

  15. Mechanical properties of intra-ocular lenses

    NASA Astrophysics Data System (ADS)

    Ehrmann, Klaus; Kim, Eon; Parel, Jean-Marie

    2008-02-01

    Cataract surgery usually involves the replacement of the natural crystalline lens with a rigid or foldable intraocular lens to restore clear vision for the patient. While great efforts have been placed on optimising the shape and optical characteristics of IOLs, little is know about the mechanical properties of these devices and how they interact with the capsular bag once implanted. Mechanical properties measurements were performed on 8 of the most commonly implanted IOLs using a custom build micro tensometer. Measurement data will be presented for the stiffness of the haptic elements, the buckling resistance of foldable IOLs, the dynamic behaviour of the different lens materials and the axial compressibility. The biggest difference between the lens types was found between one-piece and 3-piece lenses with respect to the flexibility of the haptic elements

  16. Trifocal intraocular lenses: a comparison of the visual performance and quality of vision provided by two different lens designs.

    PubMed

    Gundersen, Kjell G; Potvin, Rick

    2017-01-01

    To compare two different diffractive trifocal intraocular lens (IOL) designs, evaluating longer-term refractive outcomes, visual acuity (VA) at various distances, low contrast VA and quality of vision. Patients with binocularly implanted trifocal IOLs of two different designs (FineVision [FV] and Panoptix [PX]) were evaluated 6 months to 2 years after surgery. Best distance-corrected and uncorrected VA were tested at distance (4 m), intermediate (80 and 60 cm) and near (40 cm). A binocular defocus curve was collected with the subject's best distance correction in place. The preferred reading distance was determined along with the VA at that distance. Low contrast VA at distance was also measured. Quality of vision was measured with the National Eye Institute Visual Function Questionnaire near subset and the Quality of Vision questionnaire. Thirty subjects in each group were successfully recruited. The binocular defocus curves differed only at vergences of -1.0 D (FV better, P =0.02), -1.5 and -2.00 D (PX better, P <0.01 for both). Best distance-corrected and uncorrected binocular vision were significantly better for the PX lens at 60 cm ( P <0.01) with no significant differences at other distances. The preferred reading distance was between 42 and 43 cm for both lenses, with the VA at the preferred reading distance slightly better with the PX lens ( P =0.04). There were no statistically significant differences by lens for low contrast VA ( P =0.1) or for quality of vision measures ( P >0.3). Both trifocal lenses provided excellent distance, intermediate and near vision, but several measures indicated that the PX lens provided better intermediate vision at 60 cm. This may be important to users of tablets and other handheld devices. Quality of vision appeared similar between the two lens designs.

  17. Clinical Outcomes after Binocular Implantation of a New Trifocal Diffractive Intraocular Lens

    PubMed Central

    Kretz, Florian T. A.; Breyer, Detlev; Diakonis, Vasilios F.; Klabe, Karsten; Henke, Franziska; Auffarth, Gerd U.; Kaymak, Hakan

    2015-01-01

    Purpose. To evaluate visual, refractive, and contrast sensitivity outcomes, as well as the incidence of pseudophakic photic phenomena and patient satisfaction after bilateral diffractive trifocal intraocular lens (IOL) implantation. Methods. This prospective nonrandomized study included consecutive patients undergoing cataract surgery with bilateral implantation of a diffractive trifocal IOL (AT LISA tri 839MP, Carl Zeiss Meditec). Distance, intermediate, and near visual outcomes were evaluated as well as the defocus curve and the refractive outcomes 3 months after surgery. Photopic and mesopic contrast sensitivity, patient satisfaction, and halo perception were also evaluated. Results. Seventy-six eyes of 38 patients were included; 90% of eyes showed a spherical equivalent within ±0.50 diopters 3 months after surgery. All patients had a binocular uncorrected distance visual acuity of 0.00 LogMAR or better and a binocular uncorrected intermediate visual acuity of 0.10 LogMAR or better, 3 months after surgery. Furthermore, 85% of patients achieved a binocular uncorrected near visual acuity of 0.10 LogMAR or better. Conclusions. Trifocal diffractive IOL implantation seems to provide an effective restoration of visual function for far, intermediate, and near distances, providing high levels of visual quality and patient satisfaction. PMID:26301104

  18. [Clinical results after implantation of a new segmental refractive multifocal intraocular lens].

    PubMed

    Thomas, B C; Auffarth, G U; Philips, R; Novák, J; Blazek, J; Adamkova, H; Rabsilber, T M

    2013-11-01

    The aim of the study was a clinical evaluation of an intraocular lens (IOL) with a segmental multifocal optic design and near addition of + 3.0 D as part of a CE approval study. In a multicenter study the LENTIS Mplus LS-312 MF IOL (Oculentis) was implanted in 134 eyes of 79 patients with a mean age of 68 ± 12 years. The multifocality is achieved by implementation of a distance part and a segmented near sector. Three months after surgery, uncorrected and best corrected distance visual acuity (UCDVA and BCDVA, respectively), near visual acuity (UCNVA and BCNVA, respectively), contrast vision and patient satisfaction (questionnaire) were evaluated. The IOLs were implanted uneventfully either unilaterally or bilaterally and 3 months postoperatively (n = 86 eyes) the following mean visual acuities were obtained (logMAR): UCDVA = 0.05, BCDVA = - 0.01, UCNVA = 0.09 and BCNVA = 0.02. Contrast sensitivity (n = 25 eyes) was within normal limits. Of the 66 questioned patients 10.6% spontaneously reported halos and 3% glare. This new innovative multifocal IOL concept showed very good functional results as well as high patient satisfaction.

  19. Can the accuracy of multifocal intraocular lens power calculation be improved to make patients spectacle free?

    PubMed

    Ramji, Hasnain; Moore, Johnny; Moore, C B Tara; Shah, Sunil

    2016-04-01

    To optimise intraocular lens (IOL) power calculation techniques for a segmental multifocal IOL, LENTIS™ MPlus(®) (Oculentis GmbH, Berlin, Germany) and assess outcomes. A retrospective consecutive non-randomised case series of patients receiving the MPlus(®) IOL following cataract surgery or clear lens extraction was performed at a privately owned ophthalmic hospital, Midland Eye, Solihull, UK. Analysis was undertaken of 116 eyes, with uncomplicated lens replacement surgery using the LENTIS™ MPlus(®) lenses. Pre-operative biometry data were stratified into short (<22.00 mm) and long axial lengths (ALs) (≥22.00 mm). IOL power predictions were calculated with SRK/T, Holladay I, Hoffer Q, Holladay II and Haigis formulae and compared to the final manifest refraction. These were compared with the OKULIX ray tracing method and the stratification technique suggested by the Royal College of Ophthalmologists (RCOphth). Using SRK/T for long eyes and Hoffer Q for short eyes, 64% achieved postoperative subjective refractions of ≤±0.25 D, 83%≤±0.50 D and 93%≤±0.75 D, with a maximum predictive error of 1.25D. No specific calculation method performed best across all ALs; however for ALs under 22 mm Hoffer Q and Holliday I methods performed best. Excellent but equivalent overall refractive results were found between all biometry methods used in this multifocal IOL study. For eyes with ALs under 22 mm Hoffer Q and Holliday I performed best. Current techniques mean that patients are still likely to need top up glasses for certain situations. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Light transmission through intraocular lenses with or without yellow chromophore (blue light filter) and its potential influence on functional vision in everyday environmental conditions.

    PubMed

    Owczarek, Grzegorz; Gralewicz, Grzegorz; Skuza, Natalia; Jurowski, Piotr

    2016-01-01

    In this research the factors used to evaluate the light transmission through two types of acrylic hydrophobic intraocular lenses, one that contained yellow chromophore that blocks blue light transmission and the other which did not contain that filter, were defined according to various light condition, e.g., daylight and at night. The potential influence of light transmission trough intraocular lenses with or without yellow chromophore on functional vision in everyday environmental conditions was analysed.

  1. Clear lens phacoemulsification in Alport syndrome: refractive results and electron microscopic analysis of the anterior lens capsule.

    PubMed

    Bayar, Sezin Akca; Pinarci, Eylem Yaman; Karabay, Gulten; Akman, Ahmet; Oto, Sibel; Yilmaz, Gursel

    2014-01-01

    To report the ocular findings of patients with Alport syndrome and the results of clear lens extraction in this patient group. Twenty-three eyes of 15 patients with a diagnosis of Alport syndrome were included in this study. Clear corneal phacoemulsification and intraocular foldable lens implantation was performed in eyes with indeterminate refractive errors and/or poor visual acuity and anterior capsule samples were analyzed with electron microscopy. All patients had a history of hereditary nephritis and/or deafness as systemic involvement. Ophthalmologic examination revealed anterior lenticonus with high myopia and/or irregular astigmatism in all patients. The mean best-corrected visual acuity (BCVA) was 0.67 ± 0.17 logMAR (range 1.0-0.4) preoperatively and 0.17 ± 0.08 logMAR (range 0.3-0.0) postoperatively. Postoperative refractive lenticular astigmatism dramatically decreased and no ocular complications arose during the follow-up period. Transmission electron microscopic analysis of the lens capsules supported the diagnosis of Alport syndrome. Clear lens phacoemulsification and foldable intraocular lens implantation is a safe and effective therapeutic choice for the management of uncorrectable refractive errors and low visual acuity due to anterior lenticonus in patients with Alport syndrome.

  2. Outcomes Associated With Concurrent Iris-Sutured Intraocular Lens Placement and Subluxated Crystalline Lens Extraction.

    PubMed

    McClellan, Scott F; Soiberman, Uri; Gehlbach, Peter L; Murakami, Peter N; Stark, Walter J

    2015-08-01

    We have developed a novel surgical technique, to our knowledge, for the management of subluxated crystalline lenses involving preplacement of an iris-sutured posterior chamber intraocular lens (PCIOL) before pars plana vitrectomy and lensectomy. To investigate the outcomes of eyes with subluxated crystalline lenses, predominantly a result of Marfan syndrome (14 eyes [58%]) or trauma (5 eyes [21%]), that underwent pars plana vitrectomy and lensectomy with placement of an iris-sutured PCIOL. We performed a retrospective, noncomparative case series of 24 eyes from 17 consecutive adult patients with surgically treated subluxated crystalline lenses presenting to the Wilmer Eye Institute at Johns Hopkins Hospital from October 6, 2006, through May 1, 2013. The mean (SD) postoperative follow-up was 24.4 (20.5) months for eyes with at least 6 months of follow-up (last date, October 13, 2014). We performed the analysis from January 21, 2014, through January 3, 2015. Improvement in best-corrected visual acuity using an automated Snellen chart and induction of astigmatism for eyes with at least 6 months of follow-up (n = 18) and IOL stability during follow-up for all eyes (n = 24). The mean (SD) age at surgery was 49.4 (10.7 [range, 29-67]) years. We found an improvement in mean (SD [95% CI]) best-corrected visual acuity from 0.66 (0.71 [0.30-1.02]) logMAR preoperatively (Snellen equivalent, approximately 20/90; range, 20/30 to hand motions) to 0.07 (0.11 [95% CI, 0.01-0.12]) logMAR postoperatively (Snellen equivalent, approximately 20/23; range, 20/15 to 20/50). We found little change in astigmatism postoperatively (mean change, -0.1 [95% CI, -0.5 to 0.13] diopters). Postoperative complications included retinal detachment (1 eye [4%]), retained cortical fragment (1 [4%]), cystoid macular edema (2 [8%]), and IOL subluxation (3 [13%]) owing to haptic slippage within 3 months of the procedure. The overall probability of successfully achieving placement of a centered iris

  3. Radiation damage effects in far-ultraviolet filters, thin films, and substrates.

    PubMed

    Keffer, C E; Torr, M R; Zukic, M; Spann, J F; Torr, D G; Kim, J

    1994-09-01

    Advances in vacuum ultraviolet thin-film filter technology have been made through the use of filter designs with multilayers of materials such as Al(2)O(3), BaF(2), CaF(2), HfO(2), LaF(3), MgF(2), and SiO(2). Our immediate application for these filters will be in an imaging system to be flown on a satellite where a 2 × 9 R(E) orbit will expose the instrument to approximately 250 krad of radiation. Because to our knowledge no previous studies have been made on the potential radiation damage of these materials in the thin-film format, we report on such an assessment here. Transmittances and reflectances of BaF(2), CaF(2), HfO(2), MgF(2), and SiO(2) thin films on MgF(2) substrates, Al(2)O(3) thin films on fused-silica substrates, uncoated fused silica and MgF(2), and four multilayer filters made from these materials were measured from 120 to 180 nm beforeand after irradiation by 250 krad from a (60)Co gamma radiation source. No radiation-induced losses in transmittance or reflectance occurred in this wavelength range. Additional postradiation measurements from 160 to 300 nm indicates 2-5% radiation-induced absorption near 260 nm in some of the samples with MgF(2) substrates. From these measurements we conclude that far-ultraviolet filters made from the materials tested should experience less than 5% change from exposure to up to 250 krad of high-energy radiation in space applications.

  4. Axial movement of the dual-optic accommodating intraocular lens for the correction of the presbyopia: optical performance and clinical outcomes.

    PubMed

    Tomás-Juan, Javier; Murueta-Goyena Larrañaga, Ane

    2015-01-01

    Presbyopia occurs in the aging eye due to changes in the ciliary muscle, zonular fibers, crystalline lens, and an increased lens sclerosis. As a consequence, the capacity of accommodation decreases, which hampers to focus near objects. With the aim of restoring near vision, different devices that produce multiple focuses have been developed and introduced. However, these devices are still unable to restore accommodation. In order to achieve that goal, dual-optic accommodating Intraocular Lenses have been designed, whose anterior optic displaces axially to increase ocular power, and focus near objects. Although dual-optic accommodating IOLs are relatively new, their outcomes are promising, as they provide large amplitudes of accommodation and a greater IOL displacement than single-optic accommodating IOLs. The outcomes show comfortable near vision, higher patients' satisfaction rates, and minimal postoperative complications like Posterior Capsular Opacification and Anterior Capsular Opacification, due to their design and material. Copyright © 2014. Published by Elsevier Espana.

  5. The 1997 North American Interagency Intercomparison of Ultraviolet Spectroradiometers Including Narrowband Filter Radiometers

    PubMed Central

    Lantz, Kathleen; Disterhoft, Patrick; Early, Edward; Thompson, Ambler; DeLuisi, John; Berndt, Jerry; Harrison, Lee; Kiedron, Peter; Ehramjian, James; Bernhard, Germar; Cabasug, Lauriana; Robertson, James; Mou, Wanfeng; Taylor, Thomas; Slusser, James; Bigelow, David; Durham, Bill; Janson, George; Hayes, Douglass; Beaubien, Mark; Beaubien, Arthur

    2002-01-01

    The fourth North American Intercomparison of Ultraviolet Monitoring Spectroradiometers was held September 15 to 25, 1997 at Table Mountain outside of Boulder, Colorado, USA. Concern over stratospheric ozone depletion has prompted several government agencies in North America to establish networks of spectroradiometers for monitoring solar ultraviolet irradiance at the surface of the Earth. The main purpose of the Intercomparison was to assess the ability of spectroradiometers to accurately measure solar ultraviolet irradiance, and to compare the results between instruments of different monitoring networks. This Intercomparison was coordinated by NIST and NOAA, and included participants from the ASRC, EPA, NIST, NSF, SERC, USDA, and YES. The UV measuring instruments included scanning spectroradiometers, spectrographs, narrow band multi-filter radiometers, and broadband radiometers. Instruments were characterized for wavelength accuracy, bandwidth, stray-light rejection, and spectral irradiance responsivity. The spectral irradiance responsivity was determined two to three times outdoors to assess temporal stability. Synchronized spectral scans of the solar irradiance were performed over several days. Using the spectral irradiance responsivities determined with the NIST traceable standard lamp, and a simple convolution technique with a Gaussian slit-scattering function to account for the different bandwidths of the instruments, the measured solar irradiance from the spectroradiometers excluding the filter radiometers at 16.5 h UTC had a relative standard deviation of ±4 % for wavelengths greater than 305 nm. The relative standard deviation for the solar irradiance at 16.5 h UTC including the filter radiometer was ±4 % for filter functions above 300 nm. PMID:27446717

  6. Evaluation of a contact lens-embedded sensor for intraocular pressure measurement.

    PubMed

    Twa, Michael D; Roberts, Cynthia J; Karol, Huikai J; Mahmoud, Ashraf M; Weber, Paul A; Small, Robert H

    2010-08-01

    To evaluate a novel contact lens-embedded pressure sensor for continuous measurement of intraocular pressure (IOP). Repeated measurements of IOP and ocular pulse amplitude (OPA) were recorded in 12 eyes of 12 subjects in sitting and supine positions using 3 configurations of the dynamic contour tonometer: slit-lamp mounted (DCT), hand-held (HH), and contact lens-embedded sensor (CL). The IOP and OPA for each condition were compared using repeated measures ANOVA and the 95% limits of agreement were calculated. The sitting IOP (mean and 95% CI) for each configuration was DCT: 16.3 mm Hg (15.6 to 17.1 mm Hg), HH: 16.6 mm Hg (15.6 to 17.6 mm Hg), and CL: 15.7 mm Hg (15 to 16.3 mm Hg). The sitting OPA for each configuration was DCT: 2.4 mm Hg (2.1 to 2.6 mm Hg), HH: 2.4 mm Hg (2.1 to 2.7 mm Hg), and CL: 2.1 mm Hg (1.8 to 2.3 mm Hg). Supine IOP and OPA measurements with the CL and HH sensors were both greater than their corresponding sitting measurements, but were significantly less with the CL sensor than the HH sensor. The mean difference and 95% Limits of Agreement were smallest for the DCT and CL sensor comparisons (0.7+/-3.9 mm Hg) and widest for the CL and HH sensors (-1.9+/-7.25 mm Hg); these wider limits were attributed to greater HH measurement variability. The CL sensor was comparable to HH and DCT sensors with sitting subjects and is a viable method for measuring IOP and OPA. Supine measurements of IOP and OPA were greater than sitting conditions and were comparatively lower with the CL sensor. HH measurements were more variable than CL measurements and this influenced the Limits of Agreement for both sitting and supine conditions.

  7. Ultrastructural evaluation of explanted opacified Hydroview (H60M) intraocular lenses

    PubMed Central

    Cartwright, Nathaniel E Knox; Mayer, Eric J; McDonald, Brendan M; Skinner, Andrew; Salter, Chris J; Tole, Derek M; Sparrow, John M; Dick, Andrew D; Group, The Bristol IOL Study; Ferguson, David J P

    2007-01-01

    Aim To describe the ultrastructural appearance of explanted opacified Hydroview H60M intraocular lenses. Methods 14 explanted lenses were examined by scanning electron microscopy, and their appearance compared with a non‐implanted H60M lens from the same time period. Wavelength‐dispersive x ray spectroscopy (WDX) was performed on two opacified lenses. Results Subsurface deposits were seen in all explanted opacified lenses. These deposits broke only onto the surface of more densely opacified lenses. WDX confirmed that the deposits contained both calcium and phosphorous, consistent with their being calcium apatite. Conclusion These findings challenge the widely accepted opinion that H60M intraocular lens opacification begins on the surface of the optic. PMID:16987894

  8. Ab-interno scleral suture loop fixation with cow-hitch knot in posterior chamber intraocular lens decentration

    PubMed Central

    Can, Ertuğrul; Koçak, Nurullah; Yücel, Özlem Eşki; Gül, Adem; Öztürk, Hilal Eser; Sayın, Osman

    2016-01-01

    Aim of Study: To describe a simplified ab-interno cow-hitch suture fixation technique for repositioning decentered posterior chamber intraocular lens (PC IOL). Materials and Methods: Two cases are presented with the surgical correction of decentered and subluxated IOL. Ab-interno scleral suture fixation technique with hitch-cow knot in the eye was performed with a ciliary sulcus guide instrument and 1 year follow-up was completed. Results: Both of the patients had well centered lenses postoperatively. Corrected distant and near visual acuities of the patients were improved. There was no significant postoperative complication. In the follow-up period of 1 year, no evidence of suture erosion was found. Conclusions: Ab-interno scleral suture loop fixation with hitch-cow knot in the eye was effective in repositioning decentered or subluxated PC IOLs with excellent postoperative centered lenses and visual outcomes. PMID:27050346

  9. Ultraviolet filters in stomatopod crustaceans: diversity, ecology and evolution.

    PubMed

    Bok, Michael J; Porter, Megan L; Cronin, Thomas W

    2015-07-01

    Stomatopod crustaceans employ unique ultraviolet (UV) optical filters in order to tune the spectral sensitivities of their UV-sensitive photoreceptors. In the stomatopod species Neogonodactylus oerstedii, we previously found four filter types, produced by five distinct mycosporine-like amino acid pigments in the crystalline cones of their specialized midband ommatidial facets. This UV-spectral tuning array produces receptors with at least six distinct spectral sensitivities, despite expressing only two visual pigments. Here, we present a broad survey of these UV filters across the stomatopod order, examining their spectral absorption properties in 21 species from seven families in four superfamilies. We found that UV filters are present in three of the four superfamilies, and evolutionary character reconstruction implies that at least one class of UV filter was present in the ancestor of all modern stomatopods. Additionally, postlarval stomatopods were observed to produce the UV filters simultaneously alongside development of the adult eye. The absorbance properties of the filters are consistent within a species; however, between species we found a great deal of diversity, both in the number of filters and in their spectral absorbance characteristics. This diversity correlates with the habitat depth ranges of these species, suggesting that species living in shallow, UV-rich environments may tune their UV spectral sensitivities more aggressively. We also found additional, previously unrecognized UV filter types in the crystalline cones of the peripheral eye regions of some species, indicating the possibility for even greater stomatopod visual complexity than previously thought. © 2015. Published by The Company of Biologists Ltd.

  10. [Representation and mathematical analysis of human crystalline lens].

    PubMed

    Tălu, Stefan; Giovanzana, Stefano; Tălu, Mihai

    2011-01-01

    The surface of human crystalline lens can be described and analyzed using mathematical models based on parametric representations, used in biomechanical studies and 3D solid modeling of the lens. The mathematical models used in lens biomechanics allow the study and the behavior of crystalline lens on variables and complex dynamic loads. Also, the lens biomechanics has the potential to improve the results in the development of intraocular lenses and cataract surgery. The paper presents the most representative mathematical models currently used for the modeling of human crystalline lens, both optically and biomechanically.

  11. Color of intra-ocular lens and cataract type are prognostic determinants of health indices after visual and photoreceptive restoration by surgery.

    PubMed

    Ayaki, Masahiko; Negishi, Kazuno; Suzukamo, Yoshimi; Tsubota, Kazuo

    2015-04-01

    This study compared post-operative quality of life and sleep according to the type of cataract opacity and color of the implanted intra-ocular lens (IOL). This is a cohort study and participants were 206 patients (average age 74.1 years) undergoing cataract surgery with the implantation of a clear ultra-violet (UV)-blocking IOL (C) or a yellow blue-light-blocking IOL (Y). Participants were evaluated using the National Eye Institute Visual Function Questionnaire (VFQ-25) and Pittsburgh Sleep Quality Index (PSQI) before surgery and 2 and 7 months after surgery. Changes in sub-scale scores of VFQ-25 and PSQI were compared. Sub-scale analyses for improvement after surgery revealed significant differences in ocular pain scores on the VFQ-25 (Y>C; the higher the score, the better the outcome). Furthermore, there were significant differences between the two IOLs in terms of the sleep latency score (C>Y) and sleep disturbances score (C>Y). A posterior sub-capsular cataract was significantly correlated with improvements in ocular pain and sleep latency scores. These effects were successfully represented by the change in scores rather than absolute post-operative scores because individual standard of response may often change after intervention, recognized as a response shift phenomenon in patient-reported outcome study. Regarding seasonal differences, patients who had surgery in summer exhibited relatively better sleep quality than those who had surgery in winter. Analysis of sub-scales of health indices demonstrated characteristic prognoses for each IOL and cataract type. Cataract surgery may potentially contribute to systemic health in older adults.

  12. Coupled exposure to ingredients of cosmetic products: III. Ultraviolet filters.

    PubMed

    Uter, Wolfgang; Gonçalo, Margarida; Yazar, Kerem; Kratz, Eva-Maria; Mildau, Gerd; Lidén, Carola

    2014-09-01

    The use of cosmetics exposes consumers to mixtures of ingredients, many of which are potential allergens. Ultraviolet (UV) filters are used not just in sunscreens, but also in other products. Many UV filters are known contact allergens and photoallergens. To examine the pattern of co-exposure to UV filters in cosmetics. A survey of products marketed in Germany, conducted in 2006-2009 by the Chemical and Veterinary Investigation Office in Karlsruhe, identified 4447 products (of all 5667 cosmetic products examined) (i) that were categorizable according to Annex I to the Cosmetics Directive, and (ii) with information on the presence of UV filters or zinc oxide. The occurrence and co-occurrence of UV filters were analysed and presented in tabular and graphical format. UV filters or zinc oxide were present in 22.5% of all 4447 products, ranging from almost 100% in sunscreens to a few per cent in, for example, some hair products; they were absent in two product categories. Frequently, several different UV filters were included in one product, for example in sunscreens (median 4) and in perfumes (median 3). The overall most frequent UV filters were butyl methoxydibenzoylmethane and titanium dioxide, combined mostly with octocrylene in sunscreens and with ethylhexyl methoxycinnamate in creams. The frequent co-occurrence of UV filters in cosmetic products possibly facilitates sensitization, and may explain why patients often react to chemically unrelated UV filters. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  13. Multifocal Intraocular Lens Results in Correcting Presbyopia in Eyes After Radial Keratotomy.

    PubMed

    Kim, Kyeong Hwan; Seok, Kyung-Won; Kim, Wan Soo

    2017-11-01

    To report results of multifocal intraocular lens (IOL) implantation in 2 patients with refractive error and presbyopia after previous radial keratotomy (RK). A refractive multifocal IOL with rotational asymmetry (LS313-MF30; Oculentis, Berlin, Germany) was implanted. The first patient was a 60-year-old man with myopia who underwent unilateral RK 20 years before. His uncorrected distance visual acuity (UDVA) was 20/400, and his distance corrected near vision was J9 in both eyes. Six months after bilateral surgery, his binocular UDVA and uncorrected near visual acuity (UNVA) improved to 20/20 and J1, respectively, although he experienced diurnal fluctuation. The second patient was a 55-year-old woman with hyperopia who underwent bilateral RK 18 years before. Uncorrected distance visual acuity was 20/25 in both eyes, but UNVA was between J9 and J10. Three months after unilateral surgery, UDVA and UNVA of the postsurgical eye improved to 20/20 and J1, respectively. Neither patient reported any significant photic phenomena, and both were satisfied with the results of treatment. The desirable clinical outcomes and levels of satisfaction expressed by these patients indicate that surgery using this particular multifocal IOL may benefit presbyopic patients with previous RK.

  14. Influence of intraocular lens material and design on postoperative intracapsular cellular reactivity.

    PubMed Central

    Apple, D J

    2000-01-01

    PURPOSE: To evaluate the influence of intraocular lens (IOL) material and design on the outcome of postoperative lens epithelial cell proliferation within the capsular bag after cataract surgery. METHODS: A total of 5,079 human globes containing rigid and foldable posterior chamber IOL styles commonly implanted in the United States (n = 8) were analyzed in this study. Each globe, fixated in 10% formalin, was sectioned at the equator and analyzed using the Miyake-Apple posterior technique. The study consisted of 3 parts: First, to evaluate posterior capsule opacification (PCO); the Nd:YAG laser posterior capsulotomy rate (%) was documented and plotted on a monthly basis, creating a computerized trend line for each IOL style. Second, to evaluate anterior capsule opacification (ACO); 460 globes were processed for histologic examination. Anterior capsule fibrosis was scored from 0 to III, according to the thickness of proliferative tissue/cells on the inner surface of the anterior capsule at the capsulorhexis margin. Third, interlenticular opacification (ILO) was studied by analysis of 3 pairs of acrylic piggyback lenses that had been explanted because of opacification between their optics. Each IOL pair was processed for histologic examination, and scanning electron microscopy was performed on 1 of the lenses. RESULTS: In the first study, relatively higher Nd:YAG laser posterior capsulotomy rates (19.1% to 32.8%) were noted with the 4 oldest IOL designs in this study (2 foldable lenses, 1 3-piece polymethyl methacrylate [PMMA] design, and 1 single-piece all-PMMA design). Four modern lenses, 1 acrylic lens, and 3 silicone foldable IOL designs had Nd:YAG rates ranging from 1.3% to 14.6% (P < .0001). In the second study, mean ACO scores were highest with silicone-plate lenses (1.77 +/- 0.86 and 1.28 +/- 0.77). The lowest mean score was observed with the acrylic lens (0.51 +/- 0.52; P < .0001). In study 3, the analyses of the 3 pairs of explanted acrylic piggyback lenses

  15. New regression formula for toric intraocular lens calculations.

    PubMed

    Abulafia, Adi; Koch, Douglas D; Wang, Li; Hill, Warren E; Assia, Ehud I; Franchina, Maria; Barrett, Graham D

    2016-05-01

    To evaluate and compare the accuracy of 2 toric intraocular lens (IOL) calculators with or without a new regression formula. Ein-Tal Eye Center, Tel-Aviv, Israel, and the Lions Eye Institute, Nedlands, Western Australia, Australia. Retrospective case series. A new regression formula (Abulafia-Koch) was developed to calculate the estimated total corneal astigmatism based on standard keratometry measurements. The error in the predicted residual astigmatism was calculated by the Alcon and Holladay toric IOL calculators with and without adjustments by the Abulafia-Koch formula. These results were compared with those of the Barrett toric calculator. Data from 78 eyes were evaluated to validate the Abulafia-Koch formula. The centroid errors in predicted residual astigmatism were against-the-rule with the Alcon (0.55 diopter [D]) and Holladay (0.54 D) toric calculators and decreased to 0.05 D (P < .001 [x-axis], P = .776 [y-axis]) and 0.04 D (P < .001 [x-axis], P = .726 [y-axis]) with adjustments by the Abulafia-Koch formula. The Alcon and the Holladay toric calculators had a higher proportion of eyes within ±0.50 D of the predicted residual astigmatism with the Abulafia-Koch formula (76.9% and 78.2%, respectively) than without it (both 30.8%). There were no significant differences between the results of the Abulafia-Koch-modified Alcon and the Holladay toric calculators and those of the Barrett toric calculator. Adjustment of commercial toric IOL calculators by the Abulafia-Koch formula significantly improved the prediction of postoperative astigmatic outcome. Dr. Abulafia received a speaker's fee from Haag-Streit AG. Dr. Barrett has licensed the Barrett Toric Calculator to Haag-Streit AG. Dr. Koch is a consultant to Alcon Laboratories, Inc., Abbott Medical Optics, Inc., and Revision Optics, Inc. Dr. Hill is a paid consultant to Haag-Streit AG and Alcon Laboratories, Inc. None of the other authors has a financial or proprietary interest in any material or method

  16. Disinfection capacity of PuriLens contact lens cleaning unit against Acanthamoeba.

    PubMed

    Hwang, Thomas S; Hyon, Joon Young; Song, Jae Kyung; Reviglio, Victor E; Spahr, Harry T; O'Brien, Terrence P

    2004-01-01

    The PuriLens contact lens system is indicated for cleaning and disinfection of soft (hydrophilic) contact lenses by means of subsonic agitation to remove lens deposits and microorganisms, and ultraviolet irradiation of the storage solution for disinfection. The capacity of the PuriLens system to disinfect storage solutions contaminated with known concentrations of Staphylococcus aureus, Pseudomonas aeruginosa, and Acanthamoeba species was evaluated. An in vitro assessment of the antibacterial and antiparasitic efficacy of the PuriLens system was performed. Separated batches of the storage solution for the cleansing system were contaminated with stock strains of S. aureus and P. aeruginosa. A comparison of the microbiologic content was made between the solution before and after the cycle. The PuriLens system effectively eradicated S. aureus and P. aeruginosa organisms after a 15-minute cycle. However, viable cysts of acanthamoeba were recovered in the solution after the 15-minute cycle. The PuriLens system is highly efficient in protecting against contamination with common bacterial ocular pathogens. Acanthamoeba cysts, however, can survive in the solution or contact lens bath undergoing integrated subsonic debridement and indirect ultraviolet light disinfection. Use of chemical disinfecting solutions that contain agents such as chlorhexidine or other cationic antiseptics may be advisable in conjunction with use of the PuriLens device, especially in high-risk settings.

  17. Visual Performance of a Quadrifocal (Trifocal) Intraocular Lens Following Removal of the Crystalline Lens.

    PubMed

    Kohnen, Thomas; Herzog, Michael; Hemkeppler, Eva; Schönbrunn, Sabrina; De Lorenzo, Nina; Petermann, Kerstin; Böhm, Myriam

    2017-12-01

    To evaluate visual performance after implantation of a quadrifocal intraocular lens (IOL). Setting: Department of Ophthalmology, Goethe University, Frankfurt, Germany. Twenty-seven patients (54 eyes) received bilateral implantation of the PanOptix IOL (AcrySof IQ PanOptixTM; Alcon Research, Fort Worth, Texas, USA) pre-enrollment. Exclusion criteria were previous ocular surgeries, corneal astigmatism of >1.5 diopter (D), ocular pathologies, or corneal abnormalities. Intervention or Observational Procedure(s): Postoperative examination at 3 months including manifest refraction; uncorrected visual acuity (UCVA) and distance-corrected visual acuity (DCVA) in 4 m, 80 cm, 60 cm, and 40 cm slit-lamp examination; defocus testing; contrast sensitivity (CS) under photopic and mesopic conditions; and a questionnaire on subjective quality of vision, optical phenomena, and spectacle independence was performed. At 3 months postoperatively, UCVA and DCVA in 4 m, 80 cm, 60 cm, and 40 cm (logMAR), defocus curves, CS, and quality-of-vision questionnaire results. Mean spherical equivalent was -0.04 ± 0.321 D 3 months postoperatively. Binocular UCVA at distance, intermediate (80 cm, 60 cm), and near was 0.00 ± 0.094 logMAR, 0.09 ± 0.107 logMAR, 0.00 ± 0.111 logMAR, and 0.01 ± 0.087 logMAR, respectively. Binocular defocus curve showed peaks with best visual acuity (VA) at 0.00 D (-0.07 logMAR) and -2.00 D (-0.02 logMAR). Visual performance of the PanOptix IOL showed good VA at all distances; particularly good intermediate VA (logMAR > 0.1), with best VA at 60 cm; and high patient satisfaction and spectacle independence 3 months postoperatively. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Iris-fixated phakic intraocular lens implantation after retinal detachment surgery: long-term clinical results.

    PubMed

    Chung, Jin Kwon; Kim, Jin Kook; Lee, Jae Bum; Lee, Sung Jin

    2013-10-01

    To assess the efficacy and safety of iris-fixated phakic intraocular lens (pIOL) implantation to correct myopia in eyes with previous retinal detachment (RD) surgery. Department of Ophthalmology, Soonchunhyang University College of Medicine, Seoul, South Korea. Retrospective case series. Patients having pIOL implantation in both eyes were enrolled. Eyes that had scleral buckling or encircling (RD group) and healthy fellow eyes (non-RD group) were evaluated over a 6-year follow-up. The corrected distance visual acuity (CDVA), endothelial cell density (ECD), intraoperative complications, and long-term complications were safety outcomes. Uncorrected distance visual acuity (UDVA), predictability, and stability of refraction were efficacy outcomes. The study comprised 34 eyes (17 patients). The mean postoperative CDVA and ECD were not significantly different between groups, and no patient lost CDVA. The rate of transient intraocular pressure spike was significantly higher in the RD group (P=.043). After 3 years and 6 years, the mean postoperative UDVA was 0.06 logMAR ± 0.09 (SD) and 0.08 ± 0.10 logMAR, respectively, in the RD group and 0.04 ± 0.08 logMAR and 0.04 ± 0.09 logMAR, respectively, in the non-RD group (P=.518 and P=.478, respectively). The rate of eyes within ±0.50 diopter of the desired refraction and the postoperative refraction was not significantly different between groups. No eye had vitreoretinal changes requiring secondary surgical intervention. Iris-fixated pIOL implantation corrected the myopic refractive error in patients who had scleral buckling or encircling surgery for RD with a high degree of efficacy, safety, and long-term stability. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  19. Toric Intraocular Lens for Astigmatism Correction in Cataract Patients.

    PubMed

    Razmjoo, Hassan; Ghoreishi, Mohammad; Milasi, Azadeh Mohammadi; Peyman, Alireza; Jafarzadeh, Zahra; Mohammadinia, Mohadeseh; Kobra, Nasrollahi

    2017-01-01

    To assess the clinical consequences of AcrySof toric intraocular lens (IOL) and Hoya toric IOL implantation to correct preexisting corneal astigmatism in patients undergoing cataract surgery. In this study, we examined 55 eyes of 45 patients with at least 1.00 D corneal astigmatism who were scheduled for cataract surgery. After phacoemulsification, toric IOL was inserted and axis was aligned. We observed the patients, uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), keratometry, manifest refraction, and IOL axis alignment 6 months after surgery. After 6 months, the UDVA was 0.17 ± 0.17 logMAR in the AcrySof group and 0.17 ± 0.18 logMar in the Hoya group. More than 78% of eyes in the AcrySof group and 80% of eyes in the Hoya toric IOL achieved a UDVA of 20/40 or better. In the AcrySof group, the mean preoperative corneal astigmatism was 2.73 ± 0.92 D. The mean postoperative refractive astigmatism was 0.84 ± 0.63 D. In the Hoya group, the preoperative corneal astigmatism was 2.58 ± 0.76 D and the postoperative refractive astigmatism was 0.87 ± 0.66 D ( P < 0.05). The mean AcrySof IOL axis rotation was 1.88° ± 3.05°. In the Hoya group, the mean axis rotation was 1.53° ± 3.66°. All changes in visual and refractive data before and after surgery were statistically significant ( P < 0.05). There was no significant difference between the two groups regarding refractive and visual outcome after surgery ( P > 0.05 for all). Implantation of AcrySof toric IOL and Hoya toric IOL was an effective way to correct preexisting corneal astigmatism in cataract surgery.

  20. The prevalence of artificial lens implants in the civil airman population.

    DOT National Transportation Integrated Search

    1992-03-01

    The use of artificial lens implants to correct for aphakia has become increasingly prevalent in the United States. This study analyzes the distribution of intraocular lens (IOL) implants in the civil airman population by type (unilateral bilateral), ...

  1. Development of a program for toric intraocular lens calculation considering posterior corneal astigmatism, incision-induced posterior corneal astigmatism, and effective lens position.

    PubMed

    Eom, Youngsub; Ryu, Dongok; Kim, Dae Wook; Yang, Seul Ki; Song, Jong Suk; Kim, Sug-Whan; Kim, Hyo Myung

    2016-10-01

    To evaluate the toric intraocular lens (IOL) calculation considering posterior corneal astigmatism, incision-induced posterior corneal astigmatism, and effective lens position (ELP). Two thousand samples of corneal parameters with keratometric astigmatism ≥ 1.0 D were obtained using bootstrap methods. The probability distributions for incision-induced keratometric and posterior corneal astigmatisms, as well as ELP were estimated from the literature review. The predicted residual astigmatism error using method D with an IOL add power calculator (IAPC) was compared with those derived using methods A, B, and C through Monte-Carlo simulation. Method A considered the keratometric astigmatism and incision-induced keratometric astigmatism, method B considered posterior corneal astigmatism in addition to the A method, method C considered incision-induced posterior corneal astigmatism in addition to the B method, and method D considered ELP in addition to the C method. To verify the IAPC used in this study, the predicted toric IOL cylinder power and its axis using the IAPC were compared with ray-tracing simulation results. The median magnitude of the predicted residual astigmatism error using method D (0.25 diopters [D]) was smaller than that derived using methods A (0.42 D), B (0.38 D), and C (0.28 D) respectively. Linear regression analysis indicated that the predicted toric IOL cylinder power and its axis had excellent goodness-of-fit between the IAPC and ray-tracing simulation. The IAPC is a simple but accurate method for predicting the toric IOL cylinder power and its axis considering posterior corneal astigmatism, incision-induced posterior corneal astigmatism, and ELP.

  2. Error induced by the estimation of the corneal power and the effective lens position with a rotationally asymmetric refractive multifocal intraocular lens.

    PubMed

    Piñero, David P; Camps, Vicente J; Ramón, María L; Mateo, Verónica; Pérez-Cambrodí, Rafael J

    2015-01-01

    To evaluate the prediction error in intraocular lens (IOL) power calculation for a rotationally asymmetric refractive multifocal IOL and the impact on this error of the optimization of the keratometric estimation of the corneal power and the prediction of the effective lens position (ELP). Retrospective study including a total of 25 eyes of 13 patients (age, 50 to 83y) with previous cataract surgery with implantation of the Lentis Mplus LS-312 IOL (Oculentis GmbH, Germany). In all cases, an adjusted IOL power (PIOLadj) was calculated based on Gaussian optics using a variable keratometric index value (nkadj) for the estimation of the corneal power (Pkadj) and on a new value for ELP (ELPadj) obtained by multiple regression analysis. This PIOLadj was compared with the IOL power implanted (PIOLReal) and the value proposed by three conventional formulas (Haigis, Hoffer Q and Holladay I). PIOLReal was not significantly different than PIOLadj and Holladay IOL power (P>0.05). In the Bland and Altman analysis, PIOLadj showed lower mean difference (-0.07 D) and limits of agreement (of 1.47 and -1.61 D) when compared to PIOLReal than the IOL power value obtained with the Holladay formula. Furthermore, ELPadj was significantly lower than ELP calculated with other conventional formulas (P<0.01) and was found to be dependent on axial length, anterior chamber depth and Pkadj. Refractive outcomes after cataract surgery with implantation of the multifocal IOL Lentis Mplus LS-312 can be optimized by minimizing the keratometric error and by estimating ELP using a mathematical expression dependent on anatomical factors.

  3. Assessment of intraocular measurements in neonatal foals and association with gender, laterality, and body weight: a clinical study.

    PubMed

    Valentini, Simona; Castagnetti, Carolina; Musella, Vincenzo; Spinella, Giuseppe

    2014-01-01

    Objective of this study was to describe intraocular measurements in newly born foals (1-7 days of age) and assess the association between globe measurements and gender, laterality, and body weight. B-scan ultrasonographic biometry was performed on both eyes of 22 healthy foals (44 eyes) ages 1-7 days using a 10-MHz transducer. Intraocular measurements (anterior chamber depth, central lens thickness, vitreous chamber depth, axial globe length, longitudinal globe length, lens poles distance) were carried out using the ultrasound internal calipers. The influence of gender (male or female), laterality (right or left eye), and body weight ("light" <48 kg; "heavy" ≥48 kg) on ocular measurements was analysed by the Student t test. Values of P<0.05 were accepted as significant for all analyses. Mean anterior chamber depth was 2.2±0.5 mm (Standard Deviation); central lens thickness was 9.9±0.8 mm; vitreous chamber depth was 15.5±1.1 mm; axial globe length was 27.6±1.6 mm; longitudinal globe length was 35.8±1.2 mm, and lens poles distance was 16.4±1.0 mm. Intraocular measurements were not influenced by gender, laterality nor body weight. This study provides reference values for intraocular measurements in neonatal foals and may be useful in the diagnosis and treatment of congenital and acquired pathologies involving the globe.

  4. Simultaneous and sequential implantation of intacs and verisyse phakic intraocular lens for refractive improvement in keratectasia.

    PubMed

    Moshirfar, Majid; Fenzl, Carlton R; Meyer, Jay J; Neuffer, Marcus C; Espandar, Ladan; Mifflin, Mark D

    2011-02-01

    To evaluate the safety, efficacy, and visual outcomes of simultaneous and sequential implantation of Intacs (Addition Technology, Inc, Sunnyvale, CA) and Verisyse phakic intraocular lens (AMO, Santa Ana, CA) in selected cases of ectatic corneal disease. John A. Moran Eye Center, University of Utah, UT. Prospective data were collected from 19 eyes of 12 patients (5 eyes, post-laser in situ keratomileusis ectasia and 14 eyes, keratoconus). Intacs segments were implanted followed by insertion of a phakic Verisyse lens at the same session (12 eyes) in the simultaneous group or several months later (7 eyes) in the sequential group. The uncorrected visual acuity, best spectacle-corrected visual acuity (BSCVA), and manifest refraction were recorded at each visit. No intraoperative or postoperative complications were observed. At the last follow-up (19 ± 6 months), in the simultaneous group, mean spherical error was -0.79 ± 1.0 diopter (D) (range, -2.0 to +1.50 D) and cylindrical error +2.06 ± 1.21 D (range, +0.5 to +3.75 D). In the sequential group, at the last follow-up, at 36 ± 21 months, the mean spherical error was -1.64 ± 1.31 D (range, -3.25 to +1.0 D) and cylindrical error +2.07 ± 1.03 D (range, +0.75 to +3.25 D). There were no significant differences in mean uncorrected visual acuity or BSCVA between the 2 groups preoperatively or postoperatively. No eye lost lines of preoperative BSCVA. Combined insertion of Intacs and Verisyse was safe and effective in all cases. The outcomes of the simultaneous implantation of the Intacs and Verisyse lens in 1 surgery were similar to the results achieved with sequential implantation using 2 surgeries.

  5. The ultraviolet detection component based on Te-Cs image intensifier

    NASA Astrophysics Data System (ADS)

    Qian, Yunsheng; Zhou, Xiaoyu; Wu, Yujing; Wang, Yan; Xu, Hua

    2017-05-01

    Ultraviolet detection technology has been widely focused and adopted in the fields of ultraviolet warning and corona detection for its significant value and practical meaning. The component structure of ultraviolet ICMOS, imaging driving and the photon counting algorithm are studied in this paper. Firstly, the one-inch and wide dynamic range CMOS chip with the coupling optical fiber panel is coupled to the ultraviolet image intensifier. The photocathode material in ultraviolet image intensifier is Te-Cs, which contributes to the solar blind characteristic, and the dual micro-channel plates (MCP) structure ensures the sufficient gain to achieve the single photon counting. Then, in consideration of the ultraviolet detection demand, the drive circuit of the CMOS chip is designed and the corresponding program based on Verilog language is written. According to the characteristics of ultraviolet imaging, the histogram equalization method is applied to enhance the ultraviolet image and the connected components labeling way is utilized for the ultraviolet single photon counting. Moreover, one visible light video channel is reserved in the ultraviolet ICOMS camera, which can be used for the fusion of ultraviolet and visible images. Based upon the module, the ultraviolet optical lens and the deep cut-off solar blind filter are adopted to construct the ultraviolet detector. At last, the detection experiment of the single photon signal is carried out, and the test results are given and analyzed.

  6. Bilateral spontaneous crystalline lens dislocation to the anterior chamber: a case report.

    PubMed

    Jovanović, Milos

    2013-01-01

    There are various reasons for the lens dislocation. Spontaneous dislocation of a clear lens is extremely rare, especially its dislocation to the anterior chamber. The author presents a case of spontaneous clear lens dislocation to the anterior chamber in both eyes in a patient without the history of any trauma. Dislocation occurred spontaneously, first in the left eye, along with a sudden decrease of vision. The ophthalmologist found a clear lens in the anterior chamber, without any sign of an elevated intraocular pressure, as should have been expected. The dislocated lens was removed surgically (intracapsular extraction) with the preventive basal iridectomy. Two years later, the same happened in the right eye: clear lens moved spontaneously to the anterior chamber, with a decrease of vision, but again without any rise of intraocular pressure and/or any pain. Intracapsular extraction of the lens with basal iridectomy was done again. The presented case demonstrates that spontaneous dislocation of the transparent lens to the eye anterior chamber can occur in both eyes at different time intervals. We suggest the removal of dislocated lens in the anterior chamber by the intracapsular extraction.

  7. A study of patient satisfaction after cataract surgery with implantation of different types of intraocular lenses

    PubMed Central

    2012-01-01

    Background The implementation of capitated payment has driven medical institutions through developing balance billing for medical services. By exploring the patients’ decision-making factors on different self-pay items, a reference for the pricing and sales strategy for the related products can be formed. The major purposes of this study were to analyze the determinants of preoperative selection and postoperative satisfaction with implantation of different types of intraocular lenses in cataract surgery. Methods This cross-sectional study consisted of 127 patients that were 50 years of age and older, and who had phacoemulsification with intraocular lens implantation in both eyes. Data were collected by using a structured questionnaire. The following parameters were measured: access to medical care, attitude towards receiving medical products at one’s own expense, overall patient satisfaction and postoperative visual clarity. Results The results showed that the patient’s gender, educational level and economic status influenced the type of intraocular lens chosen. Patients in the insurance group cared about access to medical care, and patients in the balance billing group cared about product differentiation. ANOVA results showed no statistically significant differences in the overall satisfaction of the patients among the groups with different types of intraocular lenses. Patients that received cataract surgery with implantation of multifocal intraocular lenses had better vision when trying to view smaller objects and when looking at objects under strong light. Conclusions Manufacturers should increase the number of differences between their products, and health care providers can then recommend the appropriate intraocular lens in accordance with the needs or demands of their patients, and also by keeping in mind the financial constraints of their patients. PMID:23107001

  8. A study of patient satisfaction after cataract surgery with implantation of different types of intraocular lenses.

    PubMed

    Wei, Ching-Kuo; Wang, Shun-Mu; Lin, Jen-Chieh

    2012-10-29

    The implementation of capitated payment has driven medical institutions through developing balance billing for medical services. By exploring the patients' decision-making factors on different self-pay items, a reference for the pricing and sales strategy for the related products can be formed. The major purposes of this study were to analyze the determinants of preoperative selection and postoperative satisfaction with implantation of different types of intraocular lenses in cataract surgery. This cross-sectional study consisted of 127 patients that were 50 years of age and older, and who had phacoemulsification with intraocular lens implantation in both eyes. Data were collected by using a structured questionnaire. The following parameters were measured: access to medical care, attitude towards receiving medical products at one's own expense, overall patient satisfaction and postoperative visual clarity. The results showed that the patient's gender, educational level and economic status influenced the type of intraocular lens chosen. Patients in the insurance group cared about access to medical care, and patients in the balance billing group cared about product differentiation. ANOVA results showed no statistically significant differences in the overall satisfaction of the patients among the groups with different types of intraocular lenses. Patients that received cataract surgery with implantation of multifocal intraocular lenses had better vision when trying to view smaller objects and when looking at objects under strong light. Manufacturers should increase the number of differences between their products, and health care providers can then recommend the appropriate intraocular lens in accordance with the needs or demands of their patients, and also by keeping in mind the financial constraints of their patients.

  9. RGD Surface Functionalization of the Hydrophilic Acrylic Intraocular Lens Material to Control Posterior Capsular Opacification

    PubMed Central

    Huang, Yi-Shiang; Bertrand, Virginie; Bozukova, Dimitriya; Pagnoulle, Christophe; Labrugère, Christine; De Pauw, Edwin; De Pauw-Gillet, Marie-Claire; Durrieu, Marie-Christine

    2014-01-01

    Posterior Capsular Opacification (PCO) is the capsule fibrosis developed on implanted IntraOcular Lens (IOL) by the de-differentiation of Lens Epithelial Cells (LECs) undergoing Epithelial Mesenchymal Transition (EMT). Literature has shown that the incidence of PCO is multifactorial including the patient's age or disease, surgical technique, and IOL design and material. Reports comparing hydrophilic and hydrophobic acrylic IOLs have shown that the former has more severe PCO. On the other hand, we have previously demonstrated that the adhesion of LECs is favored on hydrophobic compared to hydrophilic materials. By combining these two facts and contemporary knowledge in PCO development via the EMT pathway, we propose a biomimetically inspired strategy to promote LEC adhesion without de-differentiation to reduce the risk of PCO development. By surface grafting of a cell adhesion molecule (RGD peptide) onto the conventional hydrophilic acrylic IOL material, the surface-functionalized IOL can be used to reconstitute a capsule-LEC-IOL sandwich structure, which has been considered to prevent PCO formation in literature. Our results show that the innovative biomaterial improves LEC adhesion, while also exhibiting similar optical (light transmittance, optical bench) and mechanical (haptic compression force, IOL injection force) properties compared to the starting material. In addition, compared to the hydrophobic IOL material, our bioactive biomaterial exhibits similar abilities in LEC adhesion, morphology maintenance, and EMT biomarker expression, which is the crucial pathway to induce PCO. The in vitro assays suggest that this biomaterial has the potential to reduce the risk factor of PCO development. PMID:25501012

  10. RGD surface functionalization of the hydrophilic acrylic intraocular lens material to control posterior capsular opacification.

    PubMed

    Huang, Yi-Shiang; Bertrand, Virginie; Bozukova, Dimitriya; Pagnoulle, Christophe; Labrugère, Christine; De Pauw, Edwin; De Pauw-Gillet, Marie-Claire; Durrieu, Marie-Christine

    2014-01-01

    Posterior Capsular Opacification (PCO) is the capsule fibrosis developed on implanted IntraOcular Lens (IOL) by the de-differentiation of Lens Epithelial Cells (LECs) undergoing Epithelial Mesenchymal Transition (EMT). Literature has shown that the incidence of PCO is multifactorial including the patient's age or disease, surgical technique, and IOL design and material. Reports comparing hydrophilic and hydrophobic acrylic IOLs have shown that the former has more severe PCO. On the other hand, we have previously demonstrated that the adhesion of LECs is favored on hydrophobic compared to hydrophilic materials. By combining these two facts and contemporary knowledge in PCO development via the EMT pathway, we propose a biomimetically inspired strategy to promote LEC adhesion without de-differentiation to reduce the risk of PCO development. By surface grafting of a cell adhesion molecule (RGD peptide) onto the conventional hydrophilic acrylic IOL material, the surface-functionalized IOL can be used to reconstitute a capsule-LEC-IOL sandwich structure, which has been considered to prevent PCO formation in literature. Our results show that the innovative biomaterial improves LEC adhesion, while also exhibiting similar optical (light transmittance, optical bench) and mechanical (haptic compression force, IOL injection force) properties compared to the starting material. In addition, compared to the hydrophobic IOL material, our bioactive biomaterial exhibits similar abilities in LEC adhesion, morphology maintenance, and EMT biomarker expression, which is the crucial pathway to induce PCO. The in vitro assays suggest that this biomaterial has the potential to reduce the risk factor of PCO development.

  11. The effect of melatonin on eye lens of rats exposed to ultraviolet radiation.

    PubMed

    Anwar, M M; Moustafa, M A

    2001-05-01

    We investigated the influence of exogenously administered melatonin on adult rats eye lenses exposed to ultraviolet radiation (UV) A and B ranging from 356-254 nm irradiation at 8 microW/cm(2). Rats exposed to this range of UV for 15 min for one week showed a significant (P<0.05) reduction in antioxidant enzymes activities; superoxide dismutase (SOD), glutathione peroxidase (GSH-Px) and elevated (P<0.001) lipid peroxidation served as an index of cellular damage by free radicals. UV-radiation significantly (P<0.001) elevated calcium ions (Ca(2+)) and lactate dehydrogenase (LDH) activity in lenses. Depleting animals of their stores of important intracellular antioxidant and elevating lenticular Ca(2+) by UV irradiation, may be the main cause of lens opacification. Melatonin injection with radiation significantly reduced (P<0.05) lipid peroxidation, Ca(2+) and (P<0.001) for LDH. When melatonin was injected after radiation, SOD and GSH-Px enzyme activities increased significantly (P<0.01), and lipid peroxidation, Ca(2+) levels and LDH activities were reduced significantly. Melatonin injection after UV radiation was as effective as melatonin treatment concurrent with UV irradiation. We conclude that melatonin may protect the eye lens from the damaging effects of UV exposure, and its actions protect lens from oxidative stress, elevating Ca(2+) levels, which are considered as an important causes of cataractogenesis.

  12. Comparison of the Pentacam equivalent keratometry reading and IOL Master keratometry measurement in intraocular lens power calculations.

    PubMed

    Karunaratne, Nicholas

    2013-12-01

    To compare the accuracy of the Pentacam Holladay equivalent keratometry readings with the IOL Master 500 keratometry in calculating intraocular lens power. Non-randomized, prospective clinical study conducted in private practice. Forty-five consecutive normal patients undergoing cataract surgery. Forty-five consecutive patients had Pentacam equivalent keratometry readings at the 2-, 3 and 4.5-mm corneal zone and IOL Master keratometry measurements prior to cataract surgery. For each Pentacam equivalent keratometry reading zone and IOL Master measurement the difference between the observed and expected refractive error was calculated using the Holladay 2 and Sanders, Retzlaff and Kraff theoretic (SRKT) formulas. Mean keratometric value and mean absolute refractive error. There was a statistically significantly difference between the mean keratometric values of the IOL Master, Pentacam equivalent keratometry reading 2-, 3- and 4.5-mm measurements (P < 0.0001, analysis of variance). There was no statistically significant difference between the mean absolute refraction error for the IOL Master and equivalent keratometry readings 2 mm, 3 mm and 4.5 mm zones for either the Holladay 2 formula (P = 0.14) or SRKT formula (P = 0.47). The lowest mean absolute refraction error for Holladay 2 equivalent keratometry reading was the 4.5 mm zone (mean 0.25 D ± 0.17 D). The lowest mean absolute refraction error for SRKT equivalent keratometry reading was the 4.5 mm zone (mean 0.25 D ± 0.19 D). Comparing the absolute refraction error of IOL Master and Pentacam equivalent keratometry reading, best agreement was with Holladay 2 and equivalent keratometry reading 4.5 mm, with mean of the difference of 0.02 D and 95% limits of agreement of -0.35 and 0.39 D. The IOL Master keratometry and Pentacam equivalent keratometry reading were not equivalent when used only for corneal power measurements. However, the keratometry measurements of the IOL Master and Pentacam equivalent keratometry

  13. Interaction of intraocular lenses with fibronectin and human lens epithelial cells: Effect of chemical composition and aging.

    PubMed

    Tortolano, Lionel; Serrano, Carole; Jubeli, Emile; Saunier, Johanna; Yagoubi, Najet

    2015-12-01

    The aim of this study is to investigate in vitro interactions between hydrophobic acrylate intraocular lenses (IOLs) and their biological environment. The influence of lens chemical composition and aging on fibronectin (FN) adsorption and on IOLs cytotoxicity on human lens epithelial cells was examined. Cytotoxicity of acrylate monomers used in IOLs manufacture was also investigated. Four different IOLs were included in the study: Acrysof(®), Tecnis(®), EnVista(®), and iSert(®). Implants were artificially aged in a xenon arc chamber to simulate 2 years of light exposure. Fibronectin adsorption on IOL surface was quantified using ELISA and correlated to surface roughness determined with AFM. Direct contact cytotoxicity was determined with the MTT assay and cell morphology was observed with light microscopy. Results showed that fibronectin adsorption did not differ significantly among IOLs, whatever their chemical composition. Moreover, aging conditions did not impact fibronectin adsorption. All IOLs were biocompatible even after applying 2-year aging conditions, with cell viability higher than 70%. Five acrylate monomers appeared to be toxic in the range of concentrations tested, but no monomer release from the IOLs could be detected during accelerated 2-year incubation with saline solution. This study did not reveal an influence of chemical composition and aging on protein adsorption and on biocompatibility. © 2015 Wiley Periodicals, Inc.

  14. The gravitational lens system Q0957+561 in the ultraviolet

    NASA Technical Reports Server (NTRS)

    Dolan, J. F.; Michalitsianos, A. G.; Thompson, R. W.; Boyd, P. T.; Wolinski, K. G.; Bless, R. C.; Nelson, M. J.; Percival, J. W.; Taylor, M. J.; Elliot, J. L.

    1995-01-01

    Photometric and polarimetric observations of both images of the gravitationally lensed quasar Q0957+561 (z(sub em) = 1.41) were obtained in the UV in 1993 with the High Speed Photometer on board the Hubble Space Photometer on board the Hubble Space Telescope. The images exhibited no significant polarization in a bandpass centered on 2770 A (observer's frame); p less than or = 3.2 % (2 sigma upper limit) in each image. The ratio of the flux density in image A to that in image B in late 1993 had a constant valuee, 1.021 +/- 0.008, in four different UV bandpass between 1400 A and 3040 A observer's frame). These results are consistent with the prediction of the gravitation lens interpretation that the photometric ratio of the images measured simultaneously should be independent of frequency. Reprocessed archival spectra of the two images obtained between 1981 and 1983 by the International Ultraviolet Explorer (IUE) show that the photometric ratio of A to B varies between 0.96 and 2.0 in the Ly alpha emission line, and between 0.77 and 1.8 in the O VI lambda 1037 emission line (quasar rest frame). The photometric ratio of A to B at any single epoch is often significantly different in the two emission lines. Accepting the system as a gravitational lens implies that in the quasar the flux in the Ly alpha emsisson line can vary independently of the flux in the 0 IV emission line.

  15. Assessment of Intraocular Measurements in Neonatal Foals and Association with Gender, Laterality, and Body Weight: A Clinical Study

    PubMed Central

    Valentini, Simona; Castagnetti, Carolina; Musella, Vincenzo; Spinella, Giuseppe

    2014-01-01

    Objective of this study was to describe intraocular measurements in newly born foals (1–7 days of age) and assess the association between globe measurements and gender, laterality, and body weight. B-scan ultrasonographic biometry was performed on both eyes of 22 healthy foals (44 eyes) ages 1–7 days using a 10-MHz transducer. Intraocular measurements (anterior chamber depth, central lens thickness, vitreous chamber depth, axial globe length, longitudinal globe length, lens poles distance) were carried out using the ultrasound internal calipers. The influence of gender (male or female), laterality (right or left eye), and body weight (“light” <48 kg; “heavy” ≥48 kg) on ocular measurements was analysed by the Student t test. Values of P<0.05 were accepted as significant for all analyses. Mean anterior chamber depth was 2.2±0.5 mm (Standard Deviation); central lens thickness was 9.9±0.8 mm; vitreous chamber depth was 15.5±1.1 mm; axial globe length was 27.6±1.6 mm; longitudinal globe length was 35.8±1.2 mm, and lens poles distance was 16.4±1.0 mm. Intraocular measurements were not influenced by gender, laterality nor body weight. This study provides reference values for intraocular measurements in neonatal foals and may be useful in the diagnosis and treatment of congenital and acquired pathologies involving the globe. PMID:25296286

  16. Postoperative inflammatory reactions to intraocular lense sterilized with ethylene-oxide.

    PubMed

    Stark, W J; Rosenblum, P; Maumenee, A E; Cowan, C L

    1980-05-01

    Postoperative inflammatory complications after intraocular lens implantation have increased since we have been using lenses manufactured by American companies and sterilized with ethylene-oxide, as compared with lenses from European companies sterilized by sodium hydroxide. The possible sources of this complication are discussed.

  17. Error induced by the estimation of the corneal power and the effective lens position with a rotationally asymmetric refractive multifocal intraocular lens

    PubMed Central

    Piñero, David P.; Camps, Vicente J.; Ramón, María L.; Mateo, Verónica; Pérez-Cambrodí, Rafael J.

    2015-01-01

    AIM To evaluate the prediction error in intraocular lens (IOL) power calculation for a rotationally asymmetric refractive multifocal IOL and the impact on this error of the optimization of the keratometric estimation of the corneal power and the prediction of the effective lens position (ELP). METHODS Retrospective study including a total of 25 eyes of 13 patients (age, 50 to 83y) with previous cataract surgery with implantation of the Lentis Mplus LS-312 IOL (Oculentis GmbH, Germany). In all cases, an adjusted IOL power (PIOLadj) was calculated based on Gaussian optics using a variable keratometric index value (nkadj) for the estimation of the corneal power (Pkadj) and on a new value for ELP (ELPadj) obtained by multiple regression analysis. This PIOLadj was compared with the IOL power implanted (PIOLReal) and the value proposed by three conventional formulas (Haigis, Hoffer Q and Holladay I). RESULTS PIOLReal was not significantly different than PIOLadj and Holladay IOL power (P>0.05). In the Bland and Altman analysis, PIOLadj showed lower mean difference (-0.07 D) and limits of agreement (of 1.47 and -1.61 D) when compared to PIOLReal than the IOL power value obtained with the Holladay formula. Furthermore, ELPadj was significantly lower than ELP calculated with other conventional formulas (P<0.01) and was found to be dependent on axial length, anterior chamber depth and Pkadj. CONCLUSION Refractive outcomes after cataract surgery with implantation of the multifocal IOL Lentis Mplus LS-312 can be optimized by minimizing the keratometric error and by estimating ELP using a mathematical expression dependent on anatomical factors. PMID:26085998

  18. Multiple methods of surgical treatment combined with primary IOL implantation on traumatic lens subluxation/dislocation in patients with secondary glaucoma

    PubMed Central

    Wang, Rui; Bi, Chun-Chao; Lei, Chun-Ling; Sun, Wen-Tao; Wang, Shan-Shan; Dong, Xiao-Juan

    2014-01-01

    AIM To describe clinical findings and complications from cases of traumatic lens subluxation/dislocation in patients with secondary glaucoma, and discuss the multiple treating methods of operation combined with primary intraocular lens (IOL) implantation. METHODS Non-comparative retrospective observational case series. Participants: 30 cases (30 eyes) of lens subluxation/dislocation in patients with secondary glaucoma were investigated which accepted the surgical treatment by author in the Ophthalmology of Xi'an No.4 Hospital from 2007 to 2011. According to the different situations of lens subluxation/dislocation, various surgical procedures were performed such as crystalline lens phacoemulsification, crystalline lens phacoemulsification combined anterior vitrectomy, intracapsular cataract extraction combined anterior vitrectomy, lensectomy combined anterior vitrectomy though peripheral transparent cornea incision, pars plana lensectomy combined pars plana vitrectomy, and intravitreal cavity crystalline lens phacofragmentation combined pars plana vitrectomy. And whether to implement trabeculectomy depended on the different situations of secondary glaucoma. The posterior chamber intraocular lenses (PC-IOLs) were implanted in the capsular-bag or trassclerally sutured in the sulus decided by whether the capsular were present. Main outcome measures: visual acuity, intraocular pressure, the situation of intraocular lens and complications after the operations. RESULTS The follow-up time was 11-36mo (21.4±7.13). Postoperative visual acuity of all eyes were improved; 28 cases maintained IOP below 21 mm Hg; 2 cases had slightly IOL subluxation, 4 cases had slightly tilted lens optical area; 1 case had postoperative choroidal detachment; 4 cases had postoperative corneal edema more than 1wk, but eventually recovered transparent; 2 cases had mild postoperative vitreous hemorrhage, and absorbed 4wk later. There was no postoperative retinal detachment, IOL dislocation, and

  19. Management of sulcus-fixated single-piece intraocular lens-induced pigmentary glaucoma with 3-piece IOL exchange.

    PubMed

    Rabie, Hossein Mohammad; Esfandiari, Hamed; Rikhtegar, Mohammad Hassan; Hekmat, Vahid

    2018-02-01

    To describe our experience with exchanging sulcus-fixated single-piece intraocular lens (IOL) with 3-piece IOLs for management of pigmentary glaucoma. In this retrospective study, records of patients who underwent sulcus-fixated single-piece IOL exchanged with 3-piece IOLs were retrieved, and demographic and baseline data of patients, type of IOL, pre- and post-IOL exchange BCVA, IOP, number of anti-glaucoma medications, and optic nerve head examination were documented. Baseline and final examinations were analyzed and compared. Mean age of the patients was 59 ± 10 years, and 5 (41.6%) were female. Mean interval between primary cataract extraction operation and IOL exchange was 17 ± 5 months. Nine patients received in sulcus implantation of Alcon SA60AT, and three patients had SN60WF model at the end of primary surgery. BCVA changed insignificantly from 0.06 ± 0.06 logMAR to 0.06 ± 0.06 after IOL exchange. (P = 0.22) IOP was controlled in 8 cases (66.6%), but four cases (33.3%) needed glaucoma surgery to further control glaucoma condition. IOP decreased significantly from preoperative 17 ± 3 to 14 ± 1 mmHg postoperatively. Patients with advanced age and higher baseline IOP were more likely to undergo glaucoma surgery after IOL exchange. (P = 0.07 and 0.00, respectively). single-piece IOL exchange with 3-piece IOL dramatically decreases pigment release and reduces IOP. Those with advanced age and higher IOP are less likely to respond to IOL exchange and may need glaucoma surgery to control high intraocular pressure.

  20. Polymethyl methacrylate intraocular lens opacification 20 years after cataract surgery: A case report in a tertiary eye hospital in Saudi Arabia

    PubMed Central

    Al-Otaibi, Abdullah G.; Al-Qahtani, Elham S.

    2011-01-01

    Snowflake degeneration is a slow progressive opacification of polymethyl methacrylate (PMMA) intraocular lenses (IOLs). This late postoperative complication can occur a decade or later after implantation. The deposits are composed of IOL materials that tend to aggregate centrally. There is a relative paucity of the literature on snowflake degeneration of IOLs. Symptoms can range from mild visual disturbance to significant loss of visual acuity. In cases of opacification after IOL implantation, the different diagnosis should include snowflake degeneration to prevent surgical intervention such as lens exchange or explantation unless clinically warranted. We report a case of late optical opacification of a PMMA IOL, the clinical diagnosis and treatment that increased best corrected vision. PMID:23960977

  1. Comparison of Accuracy in Intraocular Lens Power Calculation by Measuring Axial Length with Immersion Ultrasound Biometry and Partial Coherence Interferometry.

    PubMed

    Ruangsetakit, Varee

    2015-11-01

    To re-examine relative accuracy of intraocular lens (IOL) power calculation of immersion ultrasound biometry (IUB) and partial coherence interferometry (PCI) based on a new approach that limits its interest on the cases in which the IUB's IOL and PCI's IOL assignments disagree. Prospective observational study of 108 eyes that underwent cataract surgeries at Taksin Hospital. Two halves ofthe randomly chosen sample eyes were implanted with the IUB- and PCI-assigned lens. Postoperative refractive errors were measured in the fifth week. More accurate calculation was based on significantly smaller mean absolute errors (MAEs) and root mean squared errors (RMSEs) away from emmetropia. The distributions of the errors were examined to ensure that the higher accuracy was significant clinically as well. The (MAEs, RMSEs) were smaller for PCI of (0.5106 diopter (D), 0.6037D) than for IUB of (0.7000D, 0.8062D). The higher accuracy was principally contributedfrom negative errors, i.e., myopia. The MAEs and RMSEs for (IUB, PCI)'s negative errors were (0.7955D, 0.5185D) and (0.8562D, 0.5853D). Their differences were significant. The 72.34% of PCI errors fell within a clinically accepted range of ± 0.50D, whereas 50% of IUB errors did. PCI's higher accuracy was significant statistically and clinically, meaning that lens implantation based on PCI's assignments could improve postoperative outcomes over those based on IUB's assignments.

  2. Functionalised Polysiloxanes as Injectable, In Situ Curable Accommodating Intraocular Lenses

    PubMed Central

    Hao, Xiaojuan; Jeffery, Justine L.; Wilkie, John S.; Meijs, Gordon; Clayton, Anthony; Watling, Jason; Ho, Arthur; Fernandez, Viviana; Acosta, Carolina; Yamamoto, Hideo; Aly, Mohamed G. M.; Parel, Jean-Marie; Hughes, Timothy C.

    2010-01-01

    The aged eye’s ability to change focus (accommodation) may be restored by replacing the hardened natural lens with a soft gel. Functionalised polysiloxane macromonomers, designed for application as an injectable, in situ curable accommodating intraocular lens (A-IOL), were prepared via a two-step synthesis. Prepolymers were synthesised via ring opening polymerisation (ROP) of octamethylcyclotetrasiloxane (D4) and 2,4,6,8-tetramethylcyclotetrasiloxane (D4H) in toluene using trifluoromethanesulfonic acid (TfOH) as catalyst. Hexaethyldisiloxane (HEDS) was used as the end group to control the molecular weight of the prepolymers, which were then converted to macromonomers by hydrosilylation of the SiH groups with allyl methacrylate (AM) to introduce polymerisable groups. The resulting macromonomers had an injectable consistency and thus, were able to be injected into and refill the empty lens capsular bag. The macromonomers also contained a low ratio of polymerisable groups so that they may be cured on demand, in situ, under irradiation of blue light, in the presence of a photo-initiator, to form a soft polysiloxane gel (an intraocular lens) in the eye. The pre-cure viscosity and post-cure modulus of the polysiloxanes, which are crucial factors for an injectable, in situ curable A-IOL application, were controlled by adjusting the end group and D4H concentrations, respectively, in the ROP. The macromonomers were fully cured within 5 minutes under light irradiation, as shown by the rapid change in modulus monitored by photorheology. Ex vivo primate lens stretching experiments on an Ex Vivo Accommodation Simulator (EVAS) showed that the polysiloxane gel refilled lenses achieved over 60% of the accommodation amplitude of the natural lens. An in vivo biocompatibility study in rabbits using the lens refilling (Phaco-Ersatz) procedure demonstrated that the soft gels were biocompatible with the ocular tissue. The polysiloxane macromonomers meet the targeted optical and

  3. Effect of humidity on posterior lens opacification during fluid-air exchange.

    PubMed

    Harlan, J B; Lee, E T; Jensen, P S; de Juan, E

    1999-06-01

    To study the relationship of humidity and the rate of lens opacity formation during fluid-air exchange using an animal model. Vitrectomy and fluid-air exchange was carried out using 16 eyes of 8 pigmented rabbits. One eye of each rabbit was exposed to dry air and the fellow eye received humidified air using an intraocular air humidifier. In each case, the percent humidity of the intraocular air was measured using an in-line hygrometer. Elapsed time from initial air entry to lens feathering was recorded for each eye, with the surgeon-observer unaware of the percent humidity of the air infusion. In each rabbit, use of humidified air resulted in a delay in lens feathering (P<.02), with an overall increase in time to feathering of 80% for humidified air vs room air. Use of a humidifier during fluid-air exchange prolongs intraoperative lens clarity in the rabbit model, suggesting that humidified air should prolong lens clarity during phakic fluid-air exchange in patients. Use of humidified air during vitrectomy and fluid-air exchange may retard the intraoperative loss of lens clarity, promoting better visualization of the posterior segment and enhancing surgical performance.

  4. Comparison of visual function between phakic eyes and pseudophakic eyes with a monofocal intraocular lens.

    PubMed

    Hayashi, Ken; Yoshida, Motoaki; Manabe, Shin-ichi; Hayashi, Hideyuki

    2010-01-01

    To compare all-distance visual acuity and contrast visual acuity with and without glare (glare visual acuity) between phakic eyes with a clear lens and pseudophakic eyes with a monofocal intraocular lens. Hayashi Eye Hospital, Fukuoka, Japan. This study comprised phakic), pseudophakic eyes in 4 age groups (40s, 50s, 60s, 70s). Corrected visual acuity from far to near, contrast visual acuity, and glare visual acuity were examined. The mean corrected intermediate and near visual acuities were significantly better in phakic eyes than in pseudophakic eyes in patients in their 40s and 50s (P

  5. Long-Term Visual Outcomes of Secondary Intraocular Lens Implantation in Children with Congenital Cataracts

    PubMed Central

    Jiang, Yongxiang; Lu, Yi

    2015-01-01

    Aim The aim of this study was to evaluate the long-term visual outcomes and factors affecting visual results in children undergoing secondary intraocular lens (IOL) implantation following primary congenital cataract extraction. Methods Children with congenital cataracts who underwent secondary IOL implantation for aphakia at the Eye and ENT Hospital of Fudan University between January 1, 2001, and December 31, 2007, were retrospectively reviewed. One eye was randomly selected in children with bilateral cataracts. Laterality, type of cataract (total or partial opacity), sex, age at primary and secondary surgeries, visual axis opacity (VAO), compliance with amblyopia therapy, postoperative ocular complications, refractive error, ocular alignment, and best corrected visual acuity (BCVA) at last follow-up were recorded; potential factors that might have affected the visual results were evaluated. Results Seventy-six bilateral and 34 unilateral congenital cataract cases were analyzed; the mean ages of the children were 12.70±5.06 and 12.50±2.71 years at final follow-up, the mean follow-up periods from IOL implantation were 94.93±24.22 and 109.09±18.89 months, and the mean BCVA (Log MAR) values were 0.51±0.37 and 1.05±0.46, respectively. Final BCVA after secondary IOL implantation was significantly associated with laterality, type of cataract, age at primary cataract extraction, compliance with amblyopia therapy, and refractive correction after surgery. No significant associations were found between BCVA and sex, age at secondary IOL implantation, VAO, or other ocular complications. The most common ocular complications were VAO and elevated intraocular pressure after surgery. There were no other complications, with the exception of one eye with IOL dislocation. Conclusions The results indicate that the important determinants of long-term visual outcomes in children with congenital cataracts undergoing secondary IOL implantation are laterality, cataract type, age at

  6. The efficiency of aspheric intraocular lens according to biometric measurements.

    PubMed

    Whang, Woong-Joo; Piao, Junjie; Yoo, Young-Sik; Joo, Choun-Ki; Yoon, Geunyoung

    2017-01-01

    To analyze internal spherical aberration in pseudophakic eyes that underwent aspheric intraocular lens (IOL) implantation, and to investigate the relationships between biometric data and the effectiveness of aspheric IOL implantation. This retrospective study included 40 eyes of 40 patients who underwent implantation of an IOL having a negative spherical aberration of -0.20 μm (CT ASPHINA 509M; Carl Zeiss Meditec Inc., Germany). The IOLMaster (version 5.0; Carl Zeiss AG, Germany) was used for preoperative biometric measurements (axial length, anterior chamber depth, central corneal power) and the measurement of postoperative anterior chamber depth. The spherical aberrations were measured preoperatively and 3 months postoperatively using the iTrace (Tracey Technologies, Houston, TX, USA) at a pupil diameter of 5.0 mm. We investigated the relationships between preoperative biometric data and postoperative internal spherical aberration, and compared biometric measurements between 2 subgroups stratified according to internal spherical aberration (spherical aberration ≤ -0.06 μm vs. spherical aberration > -0.06 μm). The mean postoperative internal spherical aberration was -0.087 ± 0.063 μm. Preoperative axial length and residual total spherical aberration showed statistically significant correlations with internal spherical aberration (p = 0.041, 0.002). Preoperative axial length, postoperative anterior chamber depth, IOL power, and residual spherical aberration showed significant differences between the 2 subgroups stratified according to internal spherical aberration (p = 0.020, 0.029, 0.048, 0.041 respectively). The corrective effect of an aspheric IOL is influenced by preoperative axial length and postoperative anterior chamber depth. Not only the amount of negative spherical aberration on the IOL surface but also the preoperative axial length should be considered to optimize spherical aberration after aspheric IOL implantation.

  7. The effect of cataract surgery on sleep quality: a systematic review and Meta-analysis

    PubMed Central

    Zheng, Ling; Wu, Xiao-Hang; Lin, Hao-Tian

    2017-01-01

    AIM To evaluate the effect of cataract surgery on sleep quality and to compare the difference between ultraviolet-blocking clear intraocular lens (UVB-IOL) and blue-filtering intraocular lens (BF-IOL) implantation. METHODS Electronic search was performed of PubMed, MEDLINE, Embase and the Cochrane Library up to January 2016. Studies were eligible when they evaluated the sleep quality before and after cataract surgery by Pittsburgh sleep quality index (PSQI). A random/fixed-effects Meta-analysis was used for the pooled estimate. Heterogeneity was assessed with the I2 test. RESULTS Six studies were selected from 5623 references. Cataract surgery significantly reduced the PSQI scores at postoperative 0-3mo [mean difference (MD) =-0.62, 95%CI: -1.14 to -0.11, P=0.02, I2=66%] and 3-12mo (MD=-0.32, 95%CI: -0.62 to -0.02, P=0.04, I2=0), respectively. Considering different intraocular lens (IOL) implantations, relative post-operative PSQI reduction was found for both UVB-IOL and BF-IOL, but a significant reduction was detected only for UVB-IOL. No significant difference was found with the effect of BF-IOL vs UVB-IOL on sleep quality. CONCLUSION This study found that cataract surgery significantly improved the PSQI score-derived subjective sleep quality irrespective of the IOL type implanted. These findings highlight a substantial benefit of cataract surgery on systemic health with photoreceptive restoration in addition to visual acuity improvements. PMID:29181319

  8. Filters for the International Solar Terrestrial Physics (ISTP) mission far ultraviolet imager

    NASA Technical Reports Server (NTRS)

    Zukic, Muamer; Torr, Douglas G.; Kim, Jongmin; Spann, James F.; Torr, Marsha R.

    1993-01-01

    The far ultraviolet (FUV) imager for the International Solar Terrestrial Physics (ISTP) mission is designed to image four features of the aurora: O I lines at 130.4 nm and 135.6 nm and the N2 Lyman-Birge-Hopfield (LBH) bands between 140 nm - 160 nm (LBH long) and 160 nm - 180 nm (LBH long). In this paper we report the design and fabrication of narrow-band and broadband filters for the ISTP FUV imager. Narrow-band filters designed and fabricated for the O I lines have a bandwidth of less than 5 nm and a peak transmittance of 23.9 percent and 38.3 percent at 130.4 nm and 135.6 nm, respectively. Broadband filters designed and fabricated for LBH bands have the transmittance close to 60 percent. Blocking of out-of-band wavelengths for all filters is better than 5x10(exp -3) percent with the transmittance at 121.6 nm of less than 10(exp -6) percent.

  9. Scharioth Macula Lens: A new intraocular implant for low-vision patients with stabilized maculopathy- first experience.

    PubMed

    Nekolova, Jana; Rozsival, Pavel; Sin, Martin; Jiraskova, Nada

    2017-06-01

    To present the initial results of Scharioth Macula Lens (SML) implantation. The SML is a new add-on intraocular lens designed to increase uncorrected near visual acuity (UCVA) in patients with stabilized maculopathy. Eight patients were included in the study. All met the indication criteria before SML implantation. An SML was implanted in the better seeing eye. Near and distance visual acuity were tested. Possible complications and patient complaints were recorded and patients were asked about their quality of vision after SML implantation. The examination was carried out on day 1, 1 week, 1, 3 and 6 months after surgery. Six-month-results are presented. Apart from one, all patients with the SML had good near visual acuity at a recommended reading distance of 15 cm. Preoperatively, the mean (min-max) near UCVA was J13 (J8-J16), mean distance BCVA was 0.27. Postoperatively, the best results were after 1 month - near UCVA was J2.5 (J1-J7), distance BCVA was 0.26. Three months after surgery, this decreased to J4.5 (J1-J8); distance VA remained 0.25. Six months postoperatively - near vision was J4 (J1-J8) and distance VA was unchanged. Patients reported problems with reading speed and reading distance. Daily exercise improved their reading ability. One patient converted to wet AMD 3 months post-implantation. The SML is a new hope for low-vision patients. It acts as a magnifier in the eye. It is a suitable method for increasing near visual acuity in patients with inactive maculopathy.

  10. Paediatric secondary intraocular lens estimation from the aphakic refraction alone: comparison with a standard biometric technique.

    PubMed

    Khan, A O; AlGaeed, A

    2006-12-01

    To compare the following two methods of paediatric secondary posterior chamber intraocular lens (PCIOL) determination with the Holladay formula: (1) estimation from the aphakic refraction alone (using assumed keratometry (K) of 44 diopters); and (2) calculation based on preoperative measured biometry. (1) Retrospective medical record review in a referral eye hospital of children with aphakia aged < or =12 years who underwent secondary PCIOL implantation with an Alcon MA60BM lens; (2) PCIOL determination for a plano refraction by the above two methods (estimation and calculation); and (3) prediction of pseudophakic refraction for the PCIOL actually implanted by the above two methods compared with the actual pseudophakic refraction. 50 eyes of 30 children with aphakia were studied. The estimated (mean, 95% confidence interval (CI)) secondary PCIOL values (25.81, +/-1.65 D) and the calculated secondary PCIOL values (26.35, +/-1.50 D) were not significantly different (mean absolute value of the difference 1.86 D, 95% CI +/-0.41 D) by the two-tailed paired t test at alpha = 0.05 (p = 0.11). For each eye, the pseudophakic refractions predicted by the two methods for the PCIOL that was actually implanted differed, both from each other and from the actual pseudophakic refraction (repeated-measures analysis of variance, p<0.001; Tukey test, p<0.01). The method of PCIOL estimation from the aphakic refraction alone provides values similar to those obtained by a standard technique and can be useful if biometry is unavailable. Targeting a pseudophakic refraction in paediatric aphakia is prone to error.

  11. A technique of experimental and numerical analysis of influence of defects in the intraocular lens on the retinal image quality

    NASA Astrophysics Data System (ADS)

    Geniusz, Malwina; ZajÄ c, Marek

    2016-09-01

    Intraocular lens (IOL) is an artificial lens implanted into the eye in order to restore correct vision after the removal of natural lens cloudy due to cataract. The IOL prolonged stay in the eyeball causes the creation of different changes on the surface and inside the implant mainly in form of small-size local defects such as vacuoles and calcium deposites. Their presence worsens the imaging properties of the eye mainly due to occurence of scattered light thus deteriorating the vision quality of patients after cataract surgery. It is very difficult to study influence the effects of these changes on image quality in real patients. To avoid these difficulties two other possibilities were chosen: the analysis of the image obtained in an optomechanical eye model with artificially aged IOL as well as numerical calculation of the image characteristics while the eye lens is burdened with adequately modeled defects. In experiments the optomechanical model of an eye consisting of a glass "cornea", chamber filled with liquid where the IOL under investigation was inserted and a high resulution CCC detector serving as a "retina" was used. The Modulation Transfer Function (MTF) of such "eye" was evaluated on the basis of image of an edge. Experiments show that there is significant connection between ageing defects and decrease in MTF parameters. Numerical part was performed with a computer programme for optical imaging analysis (OpticStudio Professional, Zemax Professional from Radiant Zemax, LLC). On the basis of Atchison eye model with lens burdened with defects Modulation Transfer Functio was calculated. Particular parameters of defects used in a numerical model were based on own measurements. Numerical simulation also show significant connection between ageing defects and decrease of MTF parameters. With this technique the influence of types, density and distribution of local defect in the IOL on the retinal image quality can be evaluated quickly without the need of

  12. New transparent flexible nanopaper as ultraviolet filter based on red emissive Eu(III) nanofibrillated cellulose

    NASA Astrophysics Data System (ADS)

    Zhang, Zhao; Chang, Hui; Xue, Bailiang; Han, Qing; Lü, Xingqiang; Zhang, Sufeng; Li, Xinping; Zhu, Xunjin; Wong, Wai-kwok; Li, Kecheng

    2017-11-01

    A new kind of highly red emissive and transparent nanopapers as ultraviolet filter are produced from lanthanide complex Eu(TTA)3(H2O)2 grafted nanofibrillated cellulose (NFC) by a filtration process using a Buchner funnel. The nanopapers Eu-NFC 1-4 with different thickness (0.023 mm, 1; 0.04 mm, 2; 0.081 mm, 3 and 0.1 mm, 4) possess a fibres with dimensions of approximately 50 nm in diameter and several micrometres in length. Those nanopapers exhibit excellent ultraviolet A (UVA; 320-400 nm) filter property and high optical transmittance (>73% at wavelength of 600 nm). The presence of Eu(TTA)3(H2O)2 in Eu-NFC nanopapers can block 97% UVA (at 348 nm) light and convert it into pure red emission (CIE: x = 0.663, y = 0.333) through the efficient triplet-triplet energy transfer process. The efficient red emission can significantly improve the photo-stability of β-diketones type UVA filter. It can sustain for 10 h without decomposition under UV irradiation at 365 nm, which makes it possible to be applied in UVA filters. Moreover, its low coefficient of thermal expansion (CTE: 6.39 ppm K-1 of nanocellulose), is superior to petroleum-based materials for red organic light-emitting devices.

  13. Improvement of Uveal and Capsular Biocompatibility of Hydrophobic Acrylic Intraocular Lens by Surface Grafting with 2-Methacryloyloxyethyl Phosphorylcholine-Methacrylic Acid Copolymer

    PubMed Central

    Tan, Xuhua; Zhan, Jiezhao; Zhu, Yi; Cao, Ji; Wang, Lin; Liu, Sa; Wang, Yingjun; Liu, Zhenzhen; Qin, Yingyan; Wu, Mingxing; Liu, Yizhi; Ren, Li

    2017-01-01

    Biocompatibility of intraocular lens (IOL) is critical to vision reconstruction after cataract surgery. Foldable hydrophobic acrylic IOL is vulnerable to the adhesion of extracellular matrix proteins and cells, leading to increased incidence of postoperative inflammation and capsule opacification. To increase IOL biocompatibility, we synthesized a hydrophilic copolymer P(MPC-MAA) and grafted the copolymer onto the surface of IOL through air plasma treatment. X-ray photoelectron spectroscopy, atomic force microscopy and static water contact angle were used to characterize chemical changes, topography and hydrophilicity of the IOL surface, respectively. Quartz crystal microbalance with dissipation (QCM-D) showed that P(MPC-MAA) modified IOLs were resistant to protein adsorption. Moreover, P(MPC-MAA) modification inhibited adhesion and proliferation of lens epithelial cells (LECs) in vitro. To analyze uveal and capsular biocompatibility in vivo, we implanted the P(MPC-MAA) modified IOLs into rabbits after phacoemulsification. P(MPC-MAA) modification significantly reduced postoperative inflammation and anterior capsule opacification (ACO), and did not affect posterior capsule opacification (PCO). Collectively, our study suggests that surface modification by P(MPC-MAA) can significantly improve uveal and capsular biocompatibility of hydrophobic acrylic IOL, which could potentially benefit patients with blood-aqueous barrier damage. PMID:28084469

  14. Radiation Damage Effects in Far Ultraviolet Filters and Substrates

    NASA Technical Reports Server (NTRS)

    Keffer, Charles E.; Torr, Marsha R.; Zukic, Muamer; Spann, James F.; Torr, Douglas G.; Kim, Jongmin

    1993-01-01

    New advances in VUV thin film filter technology have been made using filter designs with multilayers of materials such as Al2O3, BaF2, CaF2, HfO2, LaF3, MgF2, and SiO2. Our immediate application for these filters will be in an imaging system to be flown on a satellite where a 2 X 9 R(sub E) orbit will expose the instrument to approximately 275 krads of radiation. In view of the fact that no previous studies have been made on potential radiation damage of these materials in the thin film format, we report on such an assessment here. Transmittances and reflectances of BaF2, CaF2, HfO2, LaF3, MgF2, and SiO2 thin films on MgF2 substrates, Al2O3 thin films on fused silica substrates, uncoated fused silica and MgF2, and four multilayer filters made from these materials were measured from 120 nm to 180 nm before and after irradiation by 250 krads from a Co-60 gamma radiation source. No radiation-induced losses in transmittance or reflectance occurred in this wavelength range. Additional postradiation measurements from 160 nm to 300 nm indicated a 3 - 5% radiation-induced absorption near 260 nm in some of the samples with MgF2 substrates. From these measurements it is concluded that far ultraviolet filters made from the materials tested should experience less that 5% change from exposure to up to 250 krads of high energy radiation in space applications.

  15. Intraocular lens power selection and positioning with and without intraoperative aberrometry.

    PubMed

    Hatch, Kathryn M; Woodcock, Emily C; Talamo, Jonathan H

    2015-04-01

    To determine the value of intraoperative aberrometry in cases of toric intraocular lens (IOL) implantation and positioning. In this non-randomized retrospective comparative trial, two groups of eyes underwent cataract extraction with toric IOL implantation: the aberrometry group (n = 37 eyes), where toric IOL power and alignment were determined before surgery with automated keratometry, standard optical biometry, and an online calculator and then refined using intraoperative aberrometry, and the toric calculator group (n = 27 eyes), where IOL selection was performed in a similar manner but without intraoperative aberrometry. The primary outcome measure was mean postoperative residual refractive astigmatism (RRA). Mean RRA measured at follow-up after surgery was 0.46 ± 0.42 and 0.68 ± 0.34 diopters (D) in the aberrometry and toric calculator groups, respectively (P = .0153). A 75% and 57% reduction in cylinder was noted between preoperative keratometric astigmatism and postoperative RRA in the aberrometry and toric calculator groups, respectively (P = .0027). RRA of 0.25 D or less, 0.50 D or less, 0.75 D or less, and 1.00 D or less was seen 38%, 78%, 86%, and 95% of the time, respectively, in the aberrometry group and 22%, 33%, 74%, and 89% of the time, respectively, in the toric calculator group. These data show that the chance of a patient being in a lower postoperative RRA range increased when intraoperative aberrometry was used (P = .0130). Patients undergoing cataract extraction with toric IOL placement aided by intraoperative aberrometry were 2.4 times more likely to have less than 0.50 D of RRA compared to standard methods. Copyright 2015, SLACK Incorporated.

  16. [Clinical results of the aspheric intraocular lens FY-60AD (Hoya) with particular respect to decentration and tilt].

    PubMed

    Mester, U; Heinen, S; Kaymak, H

    2010-09-01

    Aspheric intraocular lenses (IOLs) aim to improve visual function and particularly contrast vision by neutralizing spherical aberration. One drawback of such IOLs is the enhanced sensitivity to decentration and tilt, which can deteriorate image quality. A total of 30 patients who received bilateral phacoemulsification before implantation of the aspheric lens FY-60AD (Hoya) were included in a prospective study. In 25 of the patients (50 eyes) the following parameters could be assessed 3 months after surgery: visual acuity, refraction, contrast sensitivity, pupil size, wavefront errors and decentration and tilt using a newly developed device. The functional results were very satisfying and comparable to results gained with other aspheric IOLs. The mean refraction was sph + 0.1 D (±0.7 D) and cyl 0.6 D (±0.8 D). The spherical equivalent was −0.2 D (±0.6 D). Wavefront measurements revealed a good compensation of the corneal spherical aberration but vertical and horizontal coma also showed opposing values in the cornea and IOL. The assessment of the lens position using the Purkinje meter demonstrated uncritical amounts of decentration and tilt. The mean amount of decentration was 0.2 mm±0.2 mm in the horizontal and vertical directions. The mean amount of tilt was 4.0±2.1° in horizontal and 3.0±2.5° in vertical directions. In a normal dioptric power range the aspheric IOL FY-60AD compensates the corneal spherical aberration very well with only minimal decentration. The slight tilt is symmetrical in both eyes and corresponds to the position of the crystalline lens in young eyes. This may contribute to our findings of compensated corneal coma.

  17. Evaluation of paraxial forward scattering from intraocular lens with increased surface light scattering using goniophotometry and Hartmann-Shack wavefront aberrometry.

    PubMed

    Minami, Keiichiro; Maruyama, Yoko; Mihashi, Toshifumi; Miyata, Kazunori; Oshika, Tetsuro

    2017-03-01

    To evaluate the influence of increases in light scattering on intraocular lens (IOL) surfaces on paraxial forward scattering using goniophotometry and Hartmann-Shack wavefront aberrometry. Surface light scattering was reproduced experimentally by acceleratedly aging 4 intraocular lenses by 0, 3, 5, and 10 years each. Light scattering from both IOL surfaces was measured using Scheimpflug photography. The paraxial forward scattering from the aged IOLs was measured using a goniophotometer with a halogen light source (wavelength: 350-850 nm) and telecentric optics, and changes in the maximum intensity and full width at 10% of maximum intensity (FW10%) were evaluated. The influences on the retina image were examined using a Hartmann-Shack aberrometer (wavelength: 840 nm). The contrast and difference from the point spread function of the central centroids were evaluated. The mean surface light scattering from both IOL surfaces ranged from 30.0 to 118.3 computer compatible tape (CCT) and increased with each aging year. Evaluations using the goniophotometer and the Hartmann-Shack aberrometer showed no significant change in the paraxial forward scattering with the aging year (P > .45, Kruskal-Wallis test), and no association with the surface light scattering intensity was found (P > .75, Spearman rank correlation). This experimental study using aged IOLs demonstrated that surface light scattering does not influence paraxial forward scattering.

  18. Evaluation of Different Power of Near Addition in Two Different Multifocal Intraocular Lenses

    PubMed Central

    Unsal, Ugur; Baser, Gonen

    2016-01-01

    Purpose. To compare near, intermediate, and distance vision and quality of vision, when refractive rotational multifocal intraocular lenses with 3.0 diopters or diffractive multifocal intraocular lenses with 2.5 diopters near addition are implanted. Methods. 41 eyes of 41 patients in whom rotational +3.0 diopters near addition IOLs were implanted and 30 eyes of 30 patients in whom diffractive +2.5 diopters near addition IOLs were implanted after cataract surgery were reviewed. Uncorrected and corrected distance visual acuity, intermediate visual acuity, near visual acuity, and patient satisfaction were evaluated 6 months later. Results. The corrected and uncorrected distance visual acuity were the same between both groups (p = 0.50 and p = 0.509, resp.). The uncorrected intermediate and corrected intermediate and near vision acuities were better in the +2.5 near vision added intraocular lens implanted group (p = 0.049, p = 0.005, and p = 0.001, resp.) and the uncorrected near vision acuity was better in the +3.0 near vision added intraocular lens implanted group (p = 0.001). The patient satisfactions of both groups were similar. Conclusion. The +2.5 diopters near addition could be a better choice in younger patients with more distance and intermediate visual requirements (driving, outdoor activities), whereas the + 3.0 diopters should be considered for patients with more near vision correction (reading). PMID:27340560

  19. Midline sclerotomy approach for intraocular foreign body removal in phakic eyes using endoilluminator: A novel technique

    PubMed Central

    Ravani, Raghav; Chawla, Rohan; Azad, Shorya Vardhan; Gupta, Yogita; Kumar, Vinod; Kumar, Atul

    2018-01-01

    Purpose: The objective of this study is to describe the removal of retained intraocular foreign body (RIOFB) by bimanual pars plana vitrectomy through midline sclerotomy in phakic patients. Technique: Four eyes with RIOFB and clear lens underwent microincision vitrectomy surgery. A chandelier illumination was placed through one of the existing ports. The foreign body (FB) was localized by direct visualization (intravitreal) or indentation (pars plana), stabilized using an intraocular magnet/FB forceps introduced through a midline sclerotomy and freed of vitreous from all sides using a vitrectomy cutter through the other port bimanually, reoriented along their long axis and extracted through the midline sclerotomy. Results: All four FBs were removed successfully without slippage or damage to the clear lens. Conclusion: Chandelier illumination-assisted removal of FB through midline sclerotomy helps in easier localization, stabilization and removal, avoiding lens touch even in anteriorly located FBs such as at pars plana. PMID:29676316

  20. Solid intraocular xanthogranuloma in three Miniature Schnauzer dogs.

    PubMed

    Zarfoss, Mitzi K; Dubielzig, Richard R

    2007-01-01

    Macrophages that contain abundant intracytoplasmic lipid are called 'foam cells'. In four canine globes submitted to the Comparative Ocular Pathology Laboratory of Wisconsin (COPLOW), foam cells formed a solid intraocular mass. The purpose of this study was to describe the histopathologic findings in these cases. The electronic COPLOW database (1993-2006) was searched for the diagnosis of 'foam cell tumor'. Clinical history, gross pathology and histopathology (5-micron sections, hematoxylin and eosin and Alcian blue periodic acid Schiff) were reviewed in all cases. Cases were included if the globe was grossly filled by a solid mass and if all intraocular structures were effaced by lipid-laden foam cell macrophages admixed with birefringent, Alcian blue-positive crystals oriented in stellate patterns. All three patients (four globes) satisfying the selection criteria were Miniature Schnauzers. In all cases the clinical history included diabetes mellitus, hyperlipidemia and chronic bilateral uveitis that was interpreted to be lens-induced. All globes were enucleated because of glaucoma. The term solid intraocular xanthogranuloma was used to describe these cases because the intraocular contents were effaced by a solid mass of foam cells and birefringent crystals. The cases in this report suggest that diabetic Miniature Schnauzers with hyperlipidemia are at risk for lipid and macrophage-rich uveitis, which may in some cases form a solid inflammatory intraocular mass, precipitate glaucoma, and lead to enucleation.

  1. Noninvasive photoacoustic detecting intraocular foreign bodies with an annular transducer array.

    PubMed

    Yang, Diwu; Zeng, Lvming; Pan, Changning; Zhao, Xuehui; Ji, Xuanrong

    2013-01-14

    We present a fast photoacoustic imaging system based on an annular transducer array for detection of intraocular foreign bodies. An eight-channel data acquisition system is applied to capture the photoacoustic signals using multiplexing and the total time of data acquisition and transferring is within 3 s. A limited-view filtered back projection algorithm is used to reconstruct the photoacoustic images. Experimental models of intraocular metal and glass foreign bodies were constructed on ex vivo pig's eyes and clear photoacoustic images of intraocular foreign bodies were obtained. Experimental results demonstrate the photoacoustic imaging system holds the potential for in clinic detecting the intraocular foreign bodies.

  2. Rotation and decentration of an undersized plate-haptic trifocal toric intraocular lens in an eye with moderate myopia.

    PubMed

    Giers, Bert C; Khoramnia, Ramin; Weber, Lea F; Tandogan, Tamer; Auffarth, Gerd U

    2016-03-01

    We present the case of a 56-year-old woman with moderate myopia and bilateral cataract who had cataract extraction and intraocular lens (IOL) implantation. Due to the patient's desire for spectacle independence, a trifocal IOL with toric correction for astigmatism was implanted. During the follow-up, it became obvious that the implanted IOL had rotated and tilted due to insufficient fixation in the large capsular bag of the myopic eye. An IOL explantation was therefore performed, and the original IOL was exchanged for a bifocal toric IOL with a larger overall diameter. Stable fixation of the IOL in the capsular bag was achieved, and after surgery in the second eye, the patient recovered good bilateral vision. This case illustrates the need for careful selection of IOL diameter and sizing even in patients with moderate myopia due to the potentially larger ocular dimensions in these patients. Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  3. Advances in lens implant technology

    PubMed Central

    Kampik, Anselm; Dexl, Alois K.; Zimmermann, Nicole; Glasser, Adrian; Baumeister, Martin; Kohnen, Thomas

    2013-01-01

    Cataract surgery is one of the oldest and the most frequent outpatient clinic operations in medicine performed worldwide. The clouded human crystalline lens is replaced by an artificial intraocular lens implanted into the capsular bag. During the last six decades, cataract surgery has undergone rapid development from a traumatic, manual surgical procedure with implantation of a simple lens to a minimally invasive intervention increasingly assisted by high technology and a broad variety of implants customized for each patient’s individual requirements. This review discusses the major advances in this field and focuses on the main challenge remaining – the treatment of presbyopia. The demand for correction of presbyopia is increasing, reflecting the global growth of the ageing population. Pearls and pitfalls of currently applied methods to correct presbyopia and different approaches under investigation, both in lens implant technology and in surgical technology, are discussed. PMID:23413369

  4. The Enigmatic Cornea and Intraocular Lens Calculations: The LXXIII Edward Jackson Memorial Lecture.

    PubMed

    Koch, Douglas D

    2016-11-01

    To review the progress and challenges in obtaining accurate corneal power measurements for intraocular lens (IOL) calculations. Personal perspective, review of literature, case presentations, and personal data. Through literature review findings, case presentations, and data from the author's center, the types of corneal measurement errors that can occur in IOL calculation are categorized and described, along with discussion of future options to improve accuracy. Advances in IOL calculation technology and formulas have greatly increased the accuracy of IOL calculations. Recent reports suggest that over 90% of normal eyes implanted with IOLs may achieve accuracy to within 0.5 diopter (D) of the refractive target. Though errors in estimation of corneal power can cause IOL calculation errors in eyes with normal corneas, greater difficulties in measuring corneal power are encountered in eyes with diseased, scarred, and postsurgical corneas. For these corneas, problematic issues are quantifying anterior corneal power and measuring posterior corneal power and astigmatism. Results in these eyes are improving, but 2 examples illustrate current limitations: (1) spherical accuracy within 0.5 D is achieved in only 70% of eyes with post-refractive surgery corneas, and (2) astigmatism accuracy within 0.5 D is achieved in only 80% of eyes implanted with toric IOLs. Corneal power measurements are a major source of error in IOL calculations. New corneal imaging technology and IOL calculation formulas have improved outcomes and hold the promise of ongoing progress. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Optimized keratometry and total corneal astigmatism for toric intraocular lens calculation.

    PubMed

    Savini, Giacomo; Næser, Kristian; Schiano-Lomoriello, Domenico; Ducoli, Pietro

    2017-09-01

    To compare keratometric astigmatism (KA) and different modalities of measuring total corneal astigmatism (TCA) for toric intraocular lens (IOL) calculation and optimize corneal measurements to eliminate the residual refractive astigmatism. G.B. Bietti Foundation IRCCS, Rome, Italy. Prospective case series. Patients who had a toric IOL were enrolled. Preoperatively, a Scheimpflug camera (Pentacam HR) was used to measure TCA through ray tracing. Different combinations of measurements at a 3.0 mm diameter, centered on the pupil or the corneal vertex and performed along a ring or within it, were compared. Keratometric astigmatism was measured using the same Scheimpflug camera and a corneal topographer (Keratron). Astigmatism was analyzed with Næser's polar value method. The optimized preoperative corneal astigmatism was back-calculated from the postoperative refractive astigmatism. The study comprised 62 patients (64 eyes). With both devices, KA produced an overcorrection of with-the-rule (WTR) astigmatism by 0.6 diopter (D) and an undercorrection of against-the-rule (ATR) astigmatism by 0.3 D. The lowest meridional error in refractive astigmatism was achieved by the TCA pupil/zone measurement in WTR eyes (0.27 D overcorrection) and the TCA apex/zone measurement in ATR eyes (0.07 D undercorrection). In the whole sample, no measurement allowed more than 43.75% of eyes to yield an absolute error in astigmatism magnitude lower than 0.5 D. Optimized astigmatism values increased the percentage of eyes with this error up to 57.81%, with no difference compared with the Barrett calculator and the Abulafia-Koch calculator. Compared with KA, TCA improved calculations for toric IOLs; however, optimization of corneal astigmatism measurements led to more accurate results. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  6. Autorefraction versus subjective refraction in a radially asymmetric multifocal intraocular lens.

    PubMed

    van der Linden, Jan Willem; Vrijman, Violette; Al-Saady, Rana; El-Saady, Rana; van der Meulen, Ivanka J; Mourits, Maarten P; Lapid-Gortzak, Ruth

    2014-12-01

    To evaluate whether the automated refraction (AR) correlates with subjective manifest (MR) refraction in eyes implanted with radially asymmetric multifocal intraocular lens (IOLs). This retrospective study evaluated 52 eyes (52 patients) implanted with a radially asymmetric multifocal IOL (LS-312 MF30, Oculentis, Germany). At 3 months postoperatively, the AR and MR values were compared to determine the correlation between the sphere (S), the spherical equivalent (SE) and the astigmatic components J0 and J45. The difference of mean spherical measurement was +0.98D ± 0.62, with the AR measuring more myopic. The difference of the mean spherical equivalent was +1.11D ± 0.57, again with AR being more myopic. Both these differences were statistically significant (p < 0.001). The astigmatic components showed less differences, with the mean difference of the J0 being -0.09D ± 0.43, and the J45 of +0.04D ± 0.47, which were both not statistically significant (p = 0.123 and p = 0.531, respectively). Correlation analysis of the refractive parameters showed r(2) = 0.067, r(2) = 0.078, r(2) = 0.018 and r(2) = 0.015, respectively, all of which point to a low correlation between the AR and the MR. Autorefraction shows poor correlation to manifest subjective refraction with these radially asymmetric multifocal IOLs. The autorefraction systematically underestimates the spherical and spherical equivalent power, while the correlation between the astigmatic components was also low. Autorefraction seems not a valid starting point for manifest subjective refraction with these types of lenses, unless a corrective factor of about +1 dioptre is used. © 2014 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  7. Intraocular lens calculation adjustment after laser refractive surgery using Scheimpflug imaging.

    PubMed

    Schuster, Alexander K; Schanzlin, David J; Thomas, Karin E; Heichel, Christopher W; Purcell, Tracy L; Barker, Patrick D

    2016-02-01

    To test a new method of intraocular lens (IOL) calculation after corneal refractive surgery using Scheimpflug imaging (Pentacam HR) and partial coherence interferometry (PCI) (IOLMaster) that does not require historical data; that is, the Schuster/Schanzlin-Thomas-Purcell (SToP) IOL calculator. Shiley Eye Center, San Diego, California, and Walter Reed National Military Medical Center, Bethesda, Maryland, USA. Retrospective data analysis and validation study. Data were retrospectively collected from patient charts including data from Scheimpflug imaging and refractive history. Target refraction was calculated using PCI and the Holladay 1 and SRK/T formulas. Regression analysis was performed to explain the deviation of the target refraction, taking into account the following influencing factors: ratio of posterior-to-anterior corneal radius, axial length (AL), and anterior corneal radius. The regression analysis study included 61 eyes (39 patients) that had laser in situ keratomileusis (57 eyes) or photorefractive keratectomy (4 eyes) and subsequent cataract. Two factors were found that explained the deviation of the target refraction using the Holladay 1 formula; that is, the ratio of the corneal radii and the AL and the ratio of corneal radii for the SRK/T formula. A new IOL adjustment calculator was derived and validated at a second center using 14 eyes (10 patients). The error in IOL calculation for normal eyes after laser refractive treatment was related to the ratio of posterior-to-anterior corneal radius. A formula requiring Scheimpflug data and suggested IOL power only yielded an improved postoperative result for patients with previous corneal laser refractive surgery having cataract surgery. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2016 ASCRS and ESCRS. All rights reserved.

  8. Changes in the accommodation-convergence relationship after the Artisan phakic intraocular lens implantation for myopic patients.

    PubMed

    Ryu, Ik Hee; Han, Jinu; Lee, Hyung Keun; Kim, Jin Kook; Han, Sueng-Han

    2014-04-01

    To evaluate the change of accommodation-convergence parameters after implantation of Artisan phakic intraocular lens (PIOL). Prospective study for the patients with the Artisan PIOL implantation was performed. A total of 37 patients (3 males and 34 females) enrolled the study. Preoperatively, convergence amplitude, the stimulus accommodative convergence per unit of accommodation (AC/A) ratio and the near point of convergence (NPC) were evaluated. After the Artisan PIOL implantation, the identical evaluations were repeated at 1 week, 1, 3, and 6 months after the surgery. Mean age was 24.3 ± 4.8 years old, and preoperative refractive error was -8.92 ± 4.13 diopters (D). After the implantation, mean refractive errors significantly decreased to within ±1.00 D, and noticeable complications were not found. The convergence amplitude and the stimulus AC/A ratio increased 1 month after the surgery, but progressively stabilized afterward to near preoperative values. NPC didn't show any significant change over follow-up period up to 6 months. These results regarding implantation of the Artisan PIOL revealed the increase of accommodation-convergence relationship within first 1 month after the surgery, but progressive stabilization was noted during follow-up periods.

  9. Glued intraocular lens implantation for eyes with inadequate capsular support: Analysis of the postoperative visual outcome.

    PubMed

    Mohan, Sujatha; John, Bina; Rajan, Mohan; Malkani, Harsha; Nagalekshmi, S V; Singh, Siddhartha

    2017-06-01

    The aim of this study is to analyze the postoperative visual outcomes of fibrin glue-assisted, suture-less posterior chamber (PC) intraocular lens (IOL) implantation technique in eyes with inadequate capsule support at a tertiary eye care hospital in South India. This is a retrospective, nonrandomized case series. This study analyzes 94 eyes which underwent PC-IOL implantation by fibrin glue-assisted, suture-less technique. All patients who had IOL implants by the fibrin glue-assisted PC-IOL technique from August 2009 to January 2014 were included in the study. Intra- and post-operative complications were analyzed. The postoperative best spectacle-corrected visual acuity (BSCVA) was evaluated and recorded at the end of 6 months. The data were analyzed using SPSS version 16.1 (SPSS Inc., Chicago, Illinois, USA) using two sample paired t-test and independent t-test. A total of 94 eyes of 92 patients that underwent glued IOL implantation over a period of 5 years were analyzed. Out of 94 eyes, 77 eyes (84.6%) maintained or improved on their preoperative BSCVA (P = 0.012). We conclude that glued IOL implantation is a feasible option in rehabilitating patients with aphakia without adequate capsular support.

  10. Ultraviolet and short wavelength visible light exposure: why ultraviolet protection alone is not adequate.

    PubMed

    Reichow, Alan W; Citek, Karl; Edlich, Richard F

    2006-01-01

    The danger of exposure to ultraviolet (UV) radiation in both the natural environment and artificial occupational settings has long been recognized by national and international standards committees and worker safety agencies. There is an increasing body of literature that suggests that protection from UV exposure is not enough. Unprotected exposure to the short wavelengths of the visible spectrum, termed the "blue light hazard", is gaining acceptance as a true risk to long-term visual health. Global standards and experts in the field are now warning that those individuals who spend considerable time outdoors should seek sun filter eyewear with high impact resistant lenses that provide 100% UV filtration, high levels of blue light filtration, and full visual field lens/frame coverage as provided by high wrap eyewear. The Skin Cancer Foundation has endorsed certain sunglasses as "product[s]...effective [as] UV filter[s] for the eyes and surrounding skin". However, such endorsement does not necessarily mean that the eyewear meets all the protective needs for outdoor use. There are several brands that offer products with such protective characteristics. Performance sun eyewear by Nike Vision, available in both corrective and plano (nonprescription) forms, is one such brand incorporating these protective features.

  11. Long-term corneal endothelial cell changes in pediatric intraocular lens reposition and exchange cases.

    PubMed

    Wang, Yan; Wu, Mingxing; Zhu, Liyuan; Liu, Yizhi

    2012-04-01

    To evaluate long-term corneal endothelial cell changes of intraocular lens (IOL) reposition and exchange in children. State key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, 510060, China In this retrospective study, all IOL reposition and exchange procedures performed in patients under 14 years old between January 1999 and April 2009 were included. Follow-up outcomes included corneal endothelial cell density, hexagonality, coefficient of variance, average cell size. IOL reposition procedures in 12 eyes (12 cases) (reposition group, RPG), and IOL exchanges in eight eyes (eight cases) (exchange group, EXG) were performed because of IOL pupillary capture or IOL dislocation. Median of follow-up was 44.5 months in RPG and 66.2 months in EXG. The density of corneal endothelial cells in RPG (2,053 ± 493/mm(2)) and EXG (2,100 ± 758/mm(2)) was significantly decreased in comparison to the control eyes (3,116 ± 335/mm(2)). Hexagonality of corneal endothelial cells and coefficient of variance showed no difference among the control group, RPG and EXG (P > 0.05). The density of corneal endothelial cells was conspicuously decreased after IOL reposition or exchange procedures in childhood cases. Longer follow-up must be conducted in these cases.

  12. Operating microscope light-induced phototoxic maculopathy after transscleral sutured posterior chamber intraocular lens implantation.

    PubMed

    Kweon, Eui Yong; Ahn, Min; Lee, Dong Wook; You, In Cheon; Kim, Min Jung; Cho, Nam Chun

    2009-01-01

    The purpose of this study is to report the features of operating microscope light-induced retinal phototoxic maculopathy after transscleral sutured posterior chamber intraocular lens (TSS PC-IOL) implantation. The charts of 118 patients who underwent TSS PC-IOL implantation surgery at Chonbuk National University Hospital (Jeonju, Korea) between March 1999 and February 2008 were retrospectively reviewed. Fourteen patients underwent combined 3-port pars plana vitrectomy and TSS PC-IOL implantation (vitrectomy group), and 104 patients underwent TSS PC-IOL implantation only (nonvitrectomy group). All surgeries were performed under the same coaxial illuminated microscope. All diagnoses were confirmed through careful fundus examination and fluorescein angiography (FA). Diagnoses of retinal phototoxic maculopathy were established in 10 (8.47%) of 118 TSS PC-IOL implantation cases. Phototoxic maculopathy occurred more frequently in the vitrectomy group than in the nonvitrectomy group (6/14 versus 4/104, respectively; P < 0.001, chi-square = 24.21). Affected patients reported decreased vision and were found to have coarse alterations of the retinal pigment epithelium (RPE). In 5 of the phototoxic maculopathy cases (50%), the visual acuity was 20/200 or worse. Operating microscope light-induced retinal phototoxic maculopathy can occur more frequently after TSS PC-IOL implantation than after casual cataract surgery, especially when TSS PC-IOL is combined with vitrectomy surgery. Surgeons should take precautions to prevent retinal phototoxicity after TSS PC-IOL implantation and vitrectomy.

  13. Sharing of secondary electrons by in-lens and out-lens detector in low-voltage scanning electron microscope equipped with immersion lens.

    PubMed

    Kumagai, Kazuhiro; Sekiguchi, Takashi

    2009-03-01

    To understand secondary electron (SE) image formation with in-lens and out-lens detector in low-voltage scanning electron microscopy (LV-SEM), we have evaluated SE signals of an in-lens and an out-lens detector in LV-SEM. From the energy distribution spectra of SEs with various boosting voltages of the immersion lens system, we revealed that the electrostatic field of the immersion lens mainly collects electrons with energy lower than 40eV, acting as a low-pass filter. This effect is also observed as a contrast change in LV-SEM images taken by in-lens and out-lens detectors.

  14. Determination of ultraviolet filter activity on coconut oil cosmetic cream

    NASA Astrophysics Data System (ADS)

    Widiyati, Eni

    2017-08-01

    A research on determination of ultraviolet (UV) filter activity of cosmetic cream with coconut oil as raw material has been done. The cream was made by mixing the oil phase (coconut oil, stearic acid, lanolin and cetyl alcohol) at 70°C and the water phase (glycerin, aquadest and triethanolamine) at 70°C, while stirring until reached a temperature of 35°C. It was made also a cream with inorganic sunscreen TiO2 and organic sunscreen benzophenone-3 as a comparison. To study the UV filter activity, each cream was determined the UV absorption using UV spectrophotometer. The results show that cosmetic cream with coconut oil as raw material absorbs UV rays in the region of UV-C, whereas the cream with TiO2 absorbs the UV rays from UV-C to UV-A and cream with benzophenone-3 absorbs the UV rays from UV-B to UV-A region. This means that, the cosmetic cream with coconut oil as raw material has an activity as UV-C filter. If this cream is expected to have an activity as a sunscreen, it must be added an inorganic or organic sunscreen or a mixture of both as an active materials.

  15. The influence of lens power and center thickness on the intraocular pressure measured through soft lenses: a comparison of two noncontact tonometers.

    PubMed

    Ogbuehi, Kelechi C

    2012-06-01

    To quantify the influence of soft contact lens power and thickness on the intraocular pressure (IOP). Thirty-nine young, healthy adult volunteers completed this study. One eye of each subject was randomly assigned either a +6D or a -6D high water content daily disposable lens. The other eye was fitted with the second lens. Triplicate measurements of IOP were taken before, during, and after contact lens wear. Each time, IOP was assessed in a randomized order with two noncontact tonometers. The lenses were swapped between eyes during a second session of measurements, one week later. In the first session with the +6D lenses, the average IOPs (±SDs) before, with the lenses fitted, and after the lenses were removed, were: 14.3 ± 2.9 mmHg, 17.0 ± 3.3 mmHg and 13.9 ± 3.1 mmHg, respectively, for the CT80 and 13.6 ± 3.1 mmHg, 17.1 ± 4.5 mmHg and 13.3 ± 2.9 mmHg, respectively, for the PT100. The corresponding values for the first session with the -6D lenses were: 14.3 ± 3.1 mmHg, 13.1 ± 3.1 mmHg and 14.1 ± 3.3 mmHg, respectively, for the CT80 and 13.6 ± 3.2 mmHg, 13.0 ± 3.0 mmHg and 13.6 ± 3.2 mmHg, respectively, for the PT100. IOP significantly (P<0.05) increased (+ΔIOP=2.7 ± 0.4 mmHg with the CT80 in the first session) with the +6D lenses, but decreased (P<0.05) when the -6D lenses were fitted (-ΔIOP=0.6 ± 0.2 mmHg with the PT100 in the first session). The soft contact lens-induced changes were consistent between sessions but varied between tonometers. The measurement of IOP through soft contact lenses resulted in consistent, statistically significant differences in IOP, which were not uniform across tonometers and which did not appear to be solely related to the central thickness of the soft contact lenses. Copyright © 2012 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  16. Toric intraocular lens implantation versus astigmatic keratotomy to correct astigmatism during phacoemulsification.

    PubMed

    Titiyal, Jeewan S; Khatik, Mukesh; Sharma, Namrata; Sehra, Sri Vatsa; Maharana, Parfulla K; Ghatak, Urmimala; Agarwal, Tushar; Khokhar, Sudarshan; Chawla, Bhavana

    2014-05-01

    To compare toric intraocular lens (IOL) implantation and astigmatic keratotomy (AK) in correction of astigmatism during phacoemulsification. Tertiary care hospital. Prospective randomized trial. Consecutive patients with visually significant cataract and moderate astigmatism (1.25 to 3.00 diopters [D]) were randomized into 2 groups. Temporal clear corneal 2.75 mm phacoemulsification with toric IOL implantation was performed in the toric IOL group and with 30-degree coupled AK at the 7.0 mm optic zone in the keratotomy group. The uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refraction, keratometry, topography, central corneal thickness, and endothelial cell density were evaluated preoperatively and 1 day, 1 week, and 1 and 3 months postoperatively. The study enrolled 34 eyes (34 patients), 17 in each group. There was no difference in UDVA or CDVA between the 2 groups at any follow-up visit. The mean preoperative and postoperative refractive cylinder was 2.00 D ± 0.49 (SD) and 0.33 ± 0.17 D, respectively, in the toric IOL group and 1.95 ± 0.47 D and 0.57 ± 0.41 D, respectively, in the keratotomy group (P=.10). The mean residual astigmatism at 3 months was 0.44 ± 1.89 @ 160 in the toric IOL group and 0.77 ± 1.92 @ 174 in the keratotomy group (P=.61). All eyes in the toric IOL group and 14 eyes (84%) in the keratotomy group achieved a residual refractive cylinder of 1.00 D or less (P=.17). Toric IOL implantation was comparable to AK in eyes with moderate astigmatism having phacoemulsification. Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  17. An Intraocular Camera for Retinal Prostheses: Restoring Sight to the Blind

    NASA Astrophysics Data System (ADS)

    Stiles, Noelle R. B.; McIntosh, Benjamin P.; Nasiatka, Patrick J.; Hauer, Michelle C.; Weiland, James D.; Humayun, Mark S.; Tanguay, Armand R., Jr.

    Implantation of an intraocular retinal prosthesis represents one possible approach to the restoration of sight in those with minimal light perception due to photoreceptor degenerating diseases such as retinitis pigmentosa and age-related macular degeneration. In such an intraocular retinal prosthesis, a microstimulator array attached to the retina is used to electrically stimulate still-viable retinal ganglion cells that transmit retinotopic image information to the visual cortex by means of the optic nerve, thereby creating an image percept. We describe herein an intraocular camera that is designed to be implanted in the crystalline lens sac and connected to the microstimulator array. Replacement of an extraocular (head-mounted) camera with the intraocular camera restores the natural coupling of head and eye motion associated with foveation, thereby enhancing visual acquisition, navigation, and mobility tasks. This research is in no small part inspired by the unique scientific style and research methodologies that many of us have learned from Prof. Richard K. Chang of Yale University, and is included herein as an example of the extent and breadth of his impact and legacy.

  18. Effectiveness of early lens extraction for the treatment of primary angle-closure glaucoma (EAGLE): a randomised controlled trial.

    PubMed

    Azuara-Blanco, Augusto; Burr, Jennifer; Ramsay, Craig; Cooper, David; Foster, Paul J; Friedman, David S; Scotland, Graham; Javanbakht, Mehdi; Cochrane, Claire; Norrie, John

    2016-10-01

    Primary angle-closure glaucoma is a leading cause of irreversible blindness worldwide. In early-stage disease, intraocular pressure is raised without visual loss. Because the crystalline lens has a major mechanistic role, lens extraction might be a useful initial treatment. From Jan 8, 2009, to Dec 28, 2011, we enrolled patients from 30 hospital eye services in five countries. Randomisation was done by a web-based application. Patients were assigned to undergo clear-lens extraction or receive standard care with laser peripheral iridotomy and topical medical treatment. Eligible patients were aged 50 years or older, did not have cataracts, and had newly diagnosed primary angle closure with intraocular pressure 30 mm Hg or greater or primary angle-closure glaucoma. The co-primary endpoints were patient-reported health status, intraocular pressure, and incremental cost-effectiveness ratio per quality-adjusted life-year gained 36 months after treatment. Analysis was by intention to treat. This study is registered, number ISRCTN44464607. Of 419 participants enrolled, 155 had primary angle closure and 263 primary angle-closure glaucoma. 208 were assigned to clear-lens extraction and 211 to standard care, of whom 351 (84%) had complete data on health status and 366 (87%) on intraocular pressure. The mean health status score (0·87 [SD 0·12]), assessed with the European Quality of Life-5 Dimensions questionnaire, was 0·052 higher (95% CI 0·015-0·088, p=0·005) and mean intraocular pressure (16·6 [SD 3·5] mm Hg) 1·18 mm Hg lower (95% CI -1·99 to -0·38, p=0·004) after clear-lens extraction than after standard care. The incremental cost-effectiveness ratio was £14 284 for initial lens extraction versus standard care. Irreversible loss of vision occurred in one participant who underwent clear-lens extraction and three who received standard care. No patients had serious adverse events. Clear-lens extraction showed greater efficacy and was more cost-effective than

  19. Novel Ultraviolet Light Absorbing Polymers For Optical Applications

    NASA Astrophysics Data System (ADS)

    Doddi, Namassivaya; Yamada, Akira; Dunks, Gary B.

    1988-07-01

    Ultraviolet light absorbing monomers have been developed that can be copolymerized with acrylates. The composition of the resultant stable copolymers can be adjusted to totally block the transmission of light below about 430 nm. Fabrication of lenses from the materials is accomplished by lathe cutting and injection molding procedures. These ultraviolet light absorbing materials are non-mutagenic and non-toxic and are currently being used in intraocular lenses.

  20. Efficacy and safety of multifocal intraocular lenses following cataract and refractive lens exchange: Metaanalysis of peer-reviewed publications.

    PubMed

    Rosen, Emanuel; Alió, Jorge L; Dick, H Burkhard; Dell, Steven; Slade, Stephen

    2016-02-01

    We performed a metaanaysis of peer-reviewed studies involving implantation of a multifocal intraocular lens (IOL) in presbyopic patients with cataract or having refractive lens exchange (RLE). Previous reviews have considered the use of multifocal IOLs after cataract surgery but not after RLE, whereas greater insight might be gained from examining the full range of studies. Selected studies were examined to collate outcomes with monocular and binocular uncorrected distance, intermediate, and near visual acuity; spectacle independence; contrast sensitivity; visual symptoms; adverse events; and patient satisfaction. In 8797 eyes, the mean postoperative monocular uncorrected distance visual acuity (UDVA) was 0.05 logMAR ± 0.006 (SD) (Snellen equivalent 20/20(-3)). In 6334 patients, the mean binocular UDVA was 0.04 ± 0.00 logMAR (Snellen equivalent 20/20(-2)), with a mean spectacle independence of 80.1%. Monocular mean UDVA did not differ significantly between those who had a cataract procedure and those who had an RLE procedure. Neural adaptation to multifocality may vary among patients. Dr. Alió is a clinical research investigator for Hanita Lenses, Carl Zeiss Meditec AG, Topcon Medical Systems, Inc., Oculentis GmbH, and Akkolens International BV. Dr. Dell is a consultant to Bausch & Lomb and Abbott Medical Optics, Inc. Dr. Slade is a consultant to Alcon Surgical, Inc., Carl Zeiss Meditec AG, and Bausch & Lomb. None of the authors has a financial or proprietary interest in any material or method mentioned. Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  1. An angle-supported foldable phakic intraocular lens for correction of myopia: A five-year follow-up.

    PubMed

    Alió, J L; Plaza-Puche, A B; Cavas, F; Yébana Rubio, P; Sala, E

    2017-01-01

    To evaluate the efficacy and safety of an angle-supported foldable phakic intraocular lens (pIOL) for the correction of moderate to high myopia after 5 years follow-up. Prospective and retrospective, observational, longitudinal, non-randomised consecutive series of cases conducted on a total of 100 eyes of 67 patients with moderate to high myopia implanted with an Acrysof Cachet pIOL (Alcon Laboratories Inc.) with the aim of minimising the refractive error. The ages ranged between 18 to 60years. Uncorrected distance visual acuity (UDVA), manifest refraction, corrected distance visual acuity (CDVA), endothelial cells density, pIOL position, intraocular pressure, and complications were recorded preoperatively and during the 5 year follow-up. Five years after implantation, the mean manifest spherical equivalent refraction reduced significantly from -11.62±3.35 dioptres (D) to -0.33±0.85D. UDVA was 20/20 or better in 5 of 25 cases (20%), and 20/40 or better in 22 cases (88%). CDVA was 20/20 or better in 17 cases (68%), and 20/32 or better in 23 cases (92%) of eyes. The residual refractive error was within ±0.50D of emmetropia in 12 cases (48%), and within ±1.00D in 19 cases (76%). Mean endothelial cell loss at 5 years was 11.8% central, and 13.7% peripheral. Mean endothelium-pIOL distance was 2.11±0.18mm, and mean pIOL-crystalline distance was 0.88±0.20mm. This angle supported pIOL provided a favourable refractive correction and predictability, as well as acceptable safety in patients with moderate to high myopia. Although endothelial cell density decreased over 5years, the results are within the range reported in previous studies with other pIOLs. Copyright © 2016 Sociedad Española de Oftalmología. Publicado por Elsevier España, S.L.U. All rights reserved.

  2. Near-infrared transillumination photography of intraocular tumours.

    PubMed

    Krohn, Jørgen; Ulltang, Erlend; Kjersem, Bård

    2013-10-01

    To present a technique for near-infrared transillumination imaging of intraocular tumours based on the modifications of a conventional digital slit lamp camera system. The Haag-Streit Photo-Slit Lamp BX 900 (Haag-Streit AG) was used for transillumination photography by gently pressing the tip of the background illumination cable against the surface of the patient's eye. Thus the light from the flash unit was transmitted into the eye, leading to improved illumination and image resolution. The modification for near-infrared photography was done by replacing the original camera with a Canon EOS 30D (Canon Inc) converted by Advanced Camera Services Ltd. In this camera, the infrared blocking filter was exchanged for a 720 nm long-pass filter, so that the near-infrared part of the spectrum was recorded by the sensor. The technique was applied in eight patients: three with anterior choroidal melanoma, three with ciliary body melanoma and two with ocular pigment alterations. The good diagnostic quality of the photographs made it possible to evaluate the exact location and extent of the lesions in relation to pigmented intraocular landmarks such as the ora serrata and ciliary body. The photographic procedure did not lead to any complications. We recommend near-infrared transillumination photography as a supplementary diagnostic tool for the evaluation and documentation of anteriorly located intraocular tumours.

  3. The concentration of light in the human lens.

    PubMed Central

    Merriam, J C

    1996-01-01

    PURPOSE: This thesis explores the idea that light energy, especially ultraviolet light, contributes to the unequal distribution of cataract around the world and to the development of cortical opacities. METHODS: In the first section, the thesis reviews historical concepts of the function of the lens and the nature of cataract, epidemiologic data on the global distribution of cataract, and clinical observations of the predominant location of cortical opacification. Second, computer ray tracings and geometric optics demonstrate the passage of light of varying angle of incidence within the lens. Third, two models of the human eye are used to study the refraction of light by the cornea and lens and illustrate the concentration of energy at the equatorial plane of the lens. RESULTS: Cataract prevalence increases with proximity to the earth's equator, and cortical cataract is most common in the inferior and inferonasal lens. Theoretical studies and the eye models both demonstrate that the concentration of light within the lens increases with angle of incidence, and the eye models suggest that the inferior and inferonasal lens receives significantly more energy than other sections of the lens. CONCLUSION: The prevalence of cataract and exposure to ultraviolet energy both increase with decreasing latitude. The most common location of cortical cataract in the inferonasal lens is consistent with the greater dose of light energy received by this portion of the lens. These studies suggest that the global distribution of cataract and the development of cortical cataract are at least in part dependent on the dose of ultraviolet light received by the lens. Images FIGURE 1 FIGURE 2 FIGURE 27 FIGURE 28 FIGURE 29 FIGURE 31 FIGURE 32 FIGURE 33 FIGURE 34 FIGURE 36 FIGURE 37 FIGURE 38 FIGURE 50 FIGURE 51 FIGURE 52 FIGURE 53 FIGURE 54 FIGURE 56 FIGURE 60 FIGURE 61 FIGURE 63 FIGURE 64 FIGURE 65 FIGURE 68 FIGURE 69 FIGURE 70 FIGURE 71 PMID:8981716

  4. Management of bipseudophakia with implantation of an iris claw lens.

    PubMed

    Izak, Milan G J; Werner, Liliana; Izak, Andrea M; Apple, David J

    2003-07-01

    We discuss a case of bipseudophakia with secondary dislocation of a posterior chamber intraocular lens (IOL) into the anterior chamber that was managed by explantation of the anterior and posterior chamber IOLs and implantation of an iris claw IOL.

  5. Management of iatrogenic crystalline lens injury occurred during intravitreal injection.

    PubMed

    Erdogan, Gurkan; Gunay, Betul Onal; Unlu, Cihan; Gunay, Murat; Ergin, Ahmet

    2016-08-01

    To evaluate the approach to management of iatrogenic crystalline lens injury occurred during intravitreal injection (IVI). The patients who were managed operatively or followed-up without intervention after the iatrogenic lens injury due to IVI were included in the study. Capsular breaks remained either quiescent or resulted in cataract formation in the patients with inadvertent crystalline lens capsule damage. Phacoemulsification surgery was performed in patients with cataract formation with lower fluidic settings. A total of 9 cases included in the study. Seven cases underwent phacoemulsification with intraocular lens implantation. Two cases remained as quiescent lens injury during the follow-up. In 2 cases, dislocation of lens fragments occurred during phacoemulsification where pars plana vitrectomy was performed at the same session. After iatrogenic crystalline lens injury, capsular damage could remain quiescent or progress to cataract formation. Although phacoemulsification surgery can be performed with appropriate parameters, lens fragment dislocation can be observed in cases with traumatic lens damage secondary to IVI.

  6. Spectral properties of common intraocular lens (IOL) types

    NASA Astrophysics Data System (ADS)

    Milne, Peter J.; Chapon, Pascal F.; Hamaoui, Marie; Parel, Jean-Marie A.; Clayman, H.; Rol, Pascal O.

    1999-06-01

    Currently over 50 kinds of intraocular lenses (IOLs) are approved for patient use in the treatment of cataracts and ametropia. These lenses are manufactured from at least 2 kinds of silicones as well as several kinds of acrylic polymers including polyHEMA, Poly HOXEMA, a range of polymethacrylate and polyacrylate formulations. We sought to measure spectral transmission curves of a range of IOLS in the UV-visible and near IR spectral regions in order to better characterize their optical properties and to provide a baseline from which to assess their alteration following implantation over time. Consideration of how this may best be achieved are discussed. The variable ability of both explained IOLs and some samples from a range of manufacturers to block UV wavelengths is commented upon.

  7. Tunable-Bandwidth Filter System

    NASA Technical Reports Server (NTRS)

    Bailey, John W.

    2004-01-01

    A tunable-bandwidth filter system (TBFS), now undergoing development, is intended to be part of a remote sensing multispectral imaging system that will operate in the visible and near infrared spectral region (wavelengths from 400 to 900 nm). Attributes of the TBFS include rapid tunability of the pass band over a wide wavelength range and high transmission efficiency. The TBFS is based on a unique integration of two pairs of broadband Raman reflection holographic filters with two rotating spherical lenses. In experiments, a prototype of the TBFS, was shown to be capable of spectral sampling of images in the visible range over a 200 nm spectral range with a spectral resolution of 30 nm. The figure depicts the optical layout of a prototype of the TBFS as part of a laboratory multispectral imaging system for the spectral sampling of color test images in two orthogonal polarizations. Each pair of broadband Raman reflection holographic filters is mounted at an equatorial plane between two halves of a spherical lens. The two filters in each pair are characterized by steep spectral slopes (equivalently, narrow spectral edges), no ripple or side lobes in their pass bands, and a few nanometers of non-overlapping wavelength range between their pass bands. Each spherical lens and thus the filter pair within it is rotated in order to rapidly tune its pass band. The rotations of are effected by electronically controlled, programmable, high-precision rotation stages. The rotations are coordinated by electronic circuits operating under overall supervision of a personal computer in order to obtain the desired variation of the overall pass bands with time. Embedding the filters inside the spherical lenses increases the range of the hologram incidence angles, making it possible to continuously tune the pass and stop bands of the filters over a wider wavelength range. In addition, each spherical lens also serves as part of the imaging optics: The telephoto lens focuses incoming light

  8. Tunable-Bandwidth Filter System

    NASA Technical Reports Server (NTRS)

    Aye, Tin; Yu, Kevin; Dimov, Fedor; Savant, Gajendra

    2006-01-01

    A tunable-bandwidth filter system (TBFS), now undergoing development, is intended to be part of a remote-sensing multispectral imaging system that will operate in the visible and near infrared spectral region (wavelengths from 400 to 900 nm). Attributes of the TBFS include rapid tunability of the pass band over a wide wavelength range and high transmission efficiency. The TBFS is based on a unique integration of two pairs of broadband Raman reflection holographic filters with two rotating spherical lenses. In experiments, a prototype of the TBFS was shown to be capable of spectral sampling of images in the visible range over a 200-nm spectral range with a spectral resolution of .30 nm. The figure depicts the optical layout of a prototype of the TBFS as part of a laboratory multispectral imaging system for the spectral sampling of color test images in two orthogonal polarizations. Each pair of broadband Raman reflection holographic filters is mounted at an equatorial plane between two halves of a spherical lens. The two filters in each pair are characterized by steep spectral slopes (equivalently, narrow spectral edges), no ripple or side lobes in their pass bands, and a few nanometers of non-overlapping wavelength range between their pass bands. Each spherical lens and thus the filter pair within it is rotated in order to rapidly tune its pass band. The rotations of the lenses are effected by electronically controlled, programmable, high-precision rotation stages. The rotations are coordinated by electronic circuits operating under overall supervision of a personal computer in order to obtain the desired variation of the overall pass bands with time. Embedding the filters inside the spherical lenses increases the range of the hologram incidence angles, making it possible to continuously tune the pass and stop bands of the filters over a wider wavelength range. In addition, each spherical lens also serves as part of the imaging optics: The telephoto lens focuses

  9. The effect of scleral search coil lens wear on the eye.

    PubMed

    Murphy, P J; Duncan, A L; Glennie, A J; Knox, P C

    2001-03-01

    Scleral search coils are used to measure eye movements. A recent abstract suggests that the coil can affect the eye by decreasing visual acuity, increasing intraocular pressure, and damaging the corneal and conjunctival surface. Such findings, if repeated in all subjects, would cast doubt on the credibility of the search coil as a reliable investigative technique. The aim of this study was to reassess the effect of the scleral search coil on visual function. Six volunteer subjects were selected to undergo coil wear and baseline measurements were taken of logMAR visual acuity, non-contact tonometry, keratometry, and slit lamp examination. Four drops of 0.4% benoxinate hydrochloride were instilled before insertion of the lens by an experienced clinician. The lens then remained on the eye for 30 minutes. Measurements of the four ocular health parameters were repeated after 15 and 30 minutes of lens wear. The lens was then removed and the health of the eye reassessed. No obvious pattern of change was found in logMAR visual acuity, keratometry, or intraocular pressure. The lens did produce changes to the conjunctival and corneal surfaces, but this was not considered clinically significant. Search coils do not appear to cause any significant effects on visual function. However, thorough prescreening of subjects and post-wear checks should be carried out on all coil wearers to ensure no adverse effects have been caused.

  10. Enhanced Aluminum Reflecting and Solar-Blind Filter Coatings for the Far-Ultraviolet

    NASA Technical Reports Server (NTRS)

    Del Hoyo, Javier; Quijada, Manuel

    2017-01-01

    The advancement of far-ultraviolet (FUV) coatings is essential to meet the specified throughput requirements of the Large UV/Optical/IR (LUVOIR) Surveyor Observatory which will cover wavelengths down to the 100 nm range. The biggest constraint in the optical thin film coating design is attenuation in the Lyman-Alpha Ultraviolet range of 100-130 nm in which conventionally deposited thin film materials used in this spectral region (e.g. aluminum [Al] protected with Magnesium fluoride [MgF2]) often have high absorption and scatter properties degrading the throughput in an optical system. We investigate the use of optimally deposited aluminum and aluminum tri-fluoride (AlF3) materials for reflecting and solar blind band-pass filter coatings for use in the FUV. Optical characterization of the deposited designs has been performed using UV spectrometry. The optical thin film design and optimal deposition conditions to produce superior reflectance and transmittance using Al and AlF3 are presented.

  11. Enhanced aluminum reflecting and solar-blind filter coatings for the far-ultraviolet

    NASA Astrophysics Data System (ADS)

    Del Hoyo, Javier; Quijada, Manuel

    2017-09-01

    The advancement of far-ultraviolet (FUV) coatings is essential to meet the specified throughput requirements of the Large UV/Optical/IR (LUVOIR) Surveyor Observatory which will cover wavelengths down to the 100 nm range. The biggest constraint in the optical thin film coating design is attenuation in the Lyman-Alpha Ultraviolet range of 100-130 nm in which conventionally deposited thin film materials used in this spectral region (e.g., aluminum [Al] protected with Magnesium fluoride [MgF2]) often have high absorption and scatter properties degrading the throughput in an optical system. We investigate the use of optimally deposited aluminum and aluminum tri-fluoride (AlF3) materials for reflecting and solar blind band-pass filter coatings for use in the FUV. Optical characterization of the deposited designs has been performed using UV spectrometry. The optical thin film design and optimal deposition conditions to produce superior reflectance and transmittance using Al and AlF3 are presented.

  12. Changes in the Accommodation-convergence Relationship after the Artisan Phakic Intraocular Lens Implantation for Myopic Patients

    PubMed Central

    Ryu, Ik Hee; Han, Jinu; Lee, Hyung Keun; Kim, Jin Kook

    2014-01-01

    Purpose To evaluate the change of accommodation-convergence parameters after implantation of Artisan phakic intraocular lens (PIOL). Methods Prospective study for the patients with the Artisan PIOL implantation was performed. A total of 37 patients (3 males and 34 females) enrolled the study. Preoperatively, convergence amplitude, the stimulus accommodative convergence per unit of accommodation (AC/A) ratio and the near point of convergence (NPC) were evaluated. After the Artisan PIOL implantation, the identical evaluations were repeated at 1 week, 1, 3, and 6 months after the surgery. Results Mean age was 24.3 ± 4.8 years old, and preoperative refractive error was -8.92 ± 4.13 diopters (D). After the implantation, mean refractive errors significantly decreased to within ±1.00 D, and noticeable complications were not found. The convergence amplitude and the stimulus AC/A ratio increased 1 month after the surgery, but progressively stabilized afterward to near preoperative values. NPC didn't show any significant change over follow-up period up to 6 months. Conclusions These results regarding implantation of the Artisan PIOL revealed the increase of accommodation-convergence relationship within first 1 month after the surgery, but progressive stabilization was noted during follow-up periods. PMID:24688257

  13. Broadband astigmatism-corrected spectrometer design using a toroidal lens and a special filter

    NASA Astrophysics Data System (ADS)

    Ge, Xianying; Chen, Siying; Zhang, Yinchao; Chen, He; Guo, Pan; Mu, Taotao; Yang, Jian; Bu, Zhichao

    2015-01-01

    In the paper, a method to obtain a broadband, astigmatism-corrected spectrometer based on the existing Czerny-Turner spectrometer is proposed. The theories of astigmatism correction using a toroidal lens and a special filter are described in detail. Performance comparisons of the modified spectrometer and the traditional spectrometer are also presented. Results show that with the new design the RMS spot radius in sagittal view is one-eightieth of that in the traditional spectrometer over a broadband spectral range from 300 to 700 nm, without changing or moving any optical elements in the traditional spectrometer.

  14. Design and fabrication of far ultraviolet filters based on π-multilayer technology in high-k materials

    PubMed Central

    Wang, Xiao-Dong; Chen, Bo; Wang, Hai-Feng; He, Fei; Zheng, Xin; He, Ling-Ping; Chen, Bin; Liu, Shi-Jie; Cui, Zhong-Xu; Yang, Xiao-Hu; Li, Yun-Peng

    2015-01-01

    Application of π-multilayer technology is extended to high extinction coefficient materials, which is introduced into metal-dielectric filter design. Metal materials often have high extinction coefficients in far ultraviolet (FUV) region, so optical thickness of metal materials should be smaller than that of the dielectric material. A broadband FUV filter of 9-layer non-periodic Al/MgF2 multilayer was successfully designed and fabricated and it shows high reflectance in 140–180 nm, suppressed reflectance in 120–137 nm and 181–220 nm. PMID:25687255

  15. Progressive lenticular astigmatism in the clear lens.

    PubMed

    Tatham, Andrew; Prydal, Jeremy

    2008-03-01

    We describe a case of progressive lenticular astigmatism in a 53-year-old man with a clear lens. The patient acquired 5 diopters of lenticular astigmatism in his right eye over an 18-month period. The visual acuity was reduced to 6/60. Following phacoemulsification and intraocular lens implantation, the uncorrected visual acuity was 6/5. Progressive astigmatism is usually corneal in origin and in an otherwise healthy eye, significant lenticular astigmatism is rare. When lenticular astigmatism occurs, it is usually associated with a cortical cataract; however, astigmatism may precede the development of a clinically visible cataract.

  16. Quantification of the ultraviolet radiation (UVR) field in the human eye in vivo using novel instrumentation and the potential benefits of UVR blocking hydrogel contact lens.

    PubMed

    Walsh, J E; Bergmanson, J P; Wallace, D; Saldana, G; Dempsey, H; McEvoy, H; Collum, L M

    2001-09-01

    Certain degenerative eye conditions occur predominantly nasally, at the limbal region, and are associated with solar ultraviolet radiation (UVR) induced damage. The relative contribution to the in vivo ocular flux of (a) the reflection of UVR incident on the skin of the nose onto the nasal limbus, and (b) the focusing of UVR incident on the temporal side of the cornea onto the nasal limbus were examined. A novel photodiode sensor array was used to measure the UVR field across the eye. In addition, a novel spectrometer set-up was used to measure the spectrum of radiation refracted across the cornea. The efficacy of UVR blocking hydrogel contact lenses in filtering incident UVR was assessed in vivo. Qualitative and quantitative data indicated an increase nasally of UVR. Photodiode readings showed a net UVR increase from the temporal to the nasal side. Transmission curves showed that most UVR incident on the limbal region is either absorbed by, or transmitted through, the ocular tissues. This radiation is filtered by UVR blocking soft contact lens. An increased UVR flux on the nasal side of the eye, due to reflection off the nasal skin, was identified in vivo. Any UVR passing through the cornea is either absorbed by the conjunctiva and/or transmitted through it onto the sclera where it is absorbed. UVR blocking hydrogel contact lenses can eliminate these sources of UVR.

  17. ACCOMMODATIVE MOVEMENTS OF THE LENS/CAPSULE AND THE STRAND THAT EXTENDS BETWEEN THE POSTERIOR VITREOUS ZONULE INSERTION ZONE & THE LENS EQUATOR, IN RELATION TO THE VITREOUS FACE AND AGING

    PubMed Central

    CROFT, MARY ANN; HEATLEY, GREGG; MCDONALD, JARED P.; KATZ, ALEXANDER; KAUFMAN, PAUL L.

    2016-01-01

    Purpose To elucidate the dynamic accommodative movements of the lens capsule, posterior lens and the strand that attaches to the posterior vitreous zonule insertion zone and posterior lens equator (PVZ INS-LE), and their age-related changes. Methods Twelve human subjects (ages 19–65 years) and twelve rhesus monkeys (ages 6–27 years) were studied. Accommodation was induced pharmacologically (humans) or by central electrical stimulation (monkeys). Ultrasound biomicroscopy was used to image intraocular structures in both species. Surgical procedures and contrast agents were utilized in the monkey eyes to elucidate function and allow visualization of the intraocular accommodative structures. Results Human: The posterior pole of the lens moves posteriorly during accommodation in proportion to accommodative amplitude and ciliary muscle movement. Monkey: Similar accommodative movements of the posterior lens pole were seen in the monkey eyes. Following extracapsular lens extraction (ECLE), the central capsule bows backward during accommodation in proportion to accommodative amplitude and ciliary muscle movement, while the peripheral capsule moves forward. During accommodation the ciliary muscle moved forward by ~1.0 mm, pulling forward the vitreous zonule and the PVZ INS-LE structure. During the accommodative response the PVZ INS-LE structure moved forward when the lens was intact and when the lens substance and capsule were removed. In both the monkey and the human eyes these movements declined with age. Conclusions The accommodative shape change of the central capsule may be due to the elastic properties of the capsule itself. For these capsule/lens accommodative posterior movements to occur, the vitreous face must either allow for it or facilitate it. The PVZ INS-LE structure may act as a “strut” to the posterior lens equator (pushing the lens equator forward) and thereby facilitate accommodative forward lens equator movement and lens thickening. The age

  18. Regulatory effect of Bcl-2 in ultraviolet radiation-induced apoptosis of the mouse crystalline lens

    PubMed Central

    DONG, YUCHEN; ZHENG, YAJUAN; XIAO, JUN; ZHU, CHAO; ZHAO, MEISHENG

    2016-01-01

    The aim of the present study was to analyze the role of Bcl-2 during the process of apoptosis in the mouse crystalline lens. In total, 12 normal mice served as the control group and 12 Bcl-2 knockout (K.O) mice served as the experimental group. The mouse crystalline lens was sampled for the detection of Bcl-2 and caspase-3 expression following exposure to ultraviolet (UV) radiation. Reverse transcription-quantitative polymerase chain reaction (RT-qPCR) was used to determine Bcl-2 expression in the groups of normal mice receiving UV radiation or not receiving UV radiation. Samples of the murine crystalline lens were microscopically harvested and analyzed using western blotting. Apoptosis was detected using terminal deoxynucleotidyl transferase dUTP nick-end labeling (TUNEL) assay. Furthermore, caspase 3 activity was examined using enzyme-linked immunosorbent assay kits, and RT-qPCR was used to analyze caspase-3 expression levels. The results of the present study demonstrated that there was no statistically significant difference in the level of Bcl-2 gene transcription between the two groups. In addition, UV radiation did not change the macrostructure of the crystalline lens in the group of normal mice or the group of Bcl-2 K.O mice. The results of the TUNEL assay indicated that the normal-UV group exhibited a more significant apoptosis level compared with the Bcl-2 K.O-UV group. Furthermore, the mRNA expression level of caspase-3 in the normal-UV group was significantly higher compared with the normal-nonUV group (P<0.05), while the levels in the Bcl-2 K.O-UV group were significantly higher compared with the Bcl-2 K.O and normal-nonUV groups (P<0.05). In addition, the mRNA expression level of caspase-3 was significantly higher in the normal-UV, as compared with the Bcl-2 K.O-UV group (P<0.05), and the variation trends in caspase-3 activity were consistent. In conclusion, the results of the present study demonstrated that Bcl-2 may have an important role in the

  19. Regulatory effect of Bcl-2 in ultraviolet radiation-induced apoptosis of the mouse crystalline lens.

    PubMed

    Dong, Yuchen; Zheng, Yajuan; Xiao, Jun; Zhu, Chao; Zhao, Meisheng

    2016-03-01

    The aim of the present study was to analyze the role of Bcl-2 during the process of apoptosis in the mouse crystalline lens. In total, 12 normal mice served as the control group and 12 Bcl-2 knockout (K.O) mice served as the experimental group. The mouse crystalline lens was sampled for the detection of Bcl-2 and caspase-3 expression following exposure to ultraviolet (UV) radiation. Reverse transcription-quantitative polymerase chain reaction (RT-qPCR) was used to determine Bcl-2 expression in the groups of normal mice receiving UV radiation or not receiving UV radiation. Samples of the murine crystalline lens were microscopically harvested and analyzed using western blotting. Apoptosis was detected using terminal deoxynucleotidyl transferase dUTP nick-end labeling (TUNEL) assay. Furthermore, caspase 3 activity was examined using enzyme-linked immunosorbent assay kits, and RT-qPCR was used to analyze caspase-3 expression levels. The results of the present study demonstrated that there was no statistically significant difference in the level of Bcl-2 gene transcription between the two groups. In addition, UV radiation did not change the macrostructure of the crystalline lens in the group of normal mice or the group of Bcl-2 K.O mice. The results of the TUNEL assay indicated that the normal-UV group exhibited a more significant apoptosis level compared with the Bcl-2 K.O-UV group. Furthermore, the mRNA expression level of caspase-3 in the normal-UV group was significantly higher compared with the normal-nonUV group (P<0.05), while the levels in the Bcl-2 K.O-UV group were significantly higher compared with the Bcl-2 K.O and normal-nonUV groups (P<0.05). In addition, the mRNA expression level of caspase-3 was significantly higher in the normal-UV, as compared with the Bcl-2 K.O-UV group (P<0.05), and the variation trends in caspase-3 activity were consistent. In conclusion, the results of the present study demonstrated that Bcl-2 may have an important role in the

  20. New algorithm for toric intraocular lens power calculation considering the posterior corneal astigmatism.

    PubMed

    Canovas, Carmen; Alarcon, Aixa; Rosén, Robert; Kasthurirangan, Sanjeev; Ma, Joseph J K; Koch, Douglas D; Piers, Patricia

    2018-02-01

    To assess the accuracy of toric intraocular lens (IOL) power calculations of a new algorithm that incorporates the effect of posterior corneal astigmatism (PCA). Abbott Medical Optics, Inc., Groningen, the Netherlands. Retrospective case report. In eyes implanted with toric IOLs, the exact vergence formula of the Tecnis toric calculator was used to predict refractive astigmatism from preoperative biometry, surgeon-estimated surgically induced astigmatism (SIA), and implanted IOL power, with and without including the new PCA algorithm. For each calculation method, the error in predicted refractive astigmatism was calculated as the vector difference between the prediction and the actual refraction. Calculations were also made using postoperative keratometry (K) values to eliminate the potential effect of incorrect SIA estimates. The study comprised 274 eyes. The PCA algorithm significantly reduced the centroid error in predicted refractive astigmatism (P < .001). With the PCA algorithm, the centroid error reduced from 0.50 @ 1 to 0.19 @ 3 when using preoperative K values and from 0.30 @ 0 to 0.02 @ 84 when using postoperative K values. Patients who had anterior corneal against-the-rule, with-the-rule, and oblique astigmatism had improvement with the PCA algorithm. In addition, the PCA algorithm reduced the median absolute error in all groups (P < .001). The use of the new PCA algorithm decreased the error in the prediction of residual refractive astigmatism in eyes implanted with toric IOLs. Therefore, the new PCA algorithm, in combination with an exact vergence IOL power calculation formula, led to an increased predictability of toric IOL power. Copyright © 2018 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  1. Implantation of a customized toric intraocular lens for correction of post-keratoplasty astigmatism

    PubMed Central

    Srinivasan, S; Ting, D S J; Lyall, D A M

    2013-01-01

    Purpose To report visual and refractive outcomes, and endothelial cell loss following primary and secondary ‘piggyback' toric intraocular lens (IOL) implantation in patients with high post-penetrating keratoplasty (PK) astigmatism. Methods Prospective case series. Nine eyes of nine patients with post-PK astigmatism were consecutively recruited for implantation of a customized toric IOL. Six underwent simultaneous phacoemulsification (PE) and three pseudophakic eyes had a secondary ‘piggyback' toric IOL implanted in the ciliary sulcus. Mean follow-up time was 17.2±7.7 months. Pre- and post-operative uncorrected (UDVA) and best-corrected (BDVA) distance visual acuities and refractive errors were collected for comparison. Cartesian astigmatic vectors were calculated to identify a change in the magnitude of astigmatism pre- compared to postoperatively. Pre- and post-operative endothelial cell counts were also collected for analysis. Results UDVA (logMAR) improved from 1.13±0.51 preoperatively to 0.48±0.24 postoperatively (P-value=0.003). There was no significant change in BDVA (P-value=0.905) from 0.31±0.27 to 0.26±0.19. Corneal astigmatism preoperatively was 6.57±4.40 diopters (D). Post-operative refractive cylinder was 0.83±1.09 D compared to 3.89±4.01 D preoperatively (P=0.039). Analysis of astigmatic Cartesian x and y coordinates found a significant reduction postoperatively compared to preoperatively (P=0.005 and P=0.002), respectively. Mean endothelial cell loss was 9.9%. Conclusion: Implantation of a customized primary or secondary ‘piggyback' toric IOL serves as an effective modality in treating patients with high post-PK astigmatism. PMID:23348728

  2. Sulcus implantation of a 3-piece, 6.0 mm optic, hydrophobic foldable acrylic intraocular lens in phacoemulsification complicated by posterior capsule rupture.

    PubMed

    Brazitikos, Periklis D; Balidis, Miltiadis O; Tranos, Paris; Androudi, Sofia; Papadopoulos, Nick T; Tsinopoulos, Ioannis T; Karabatakis, Vasilios; Stangos, Nikolaos T

    2002-09-01

    To evaluate the safety of implanting a 3-piece, 6.0 mm optic, foldable acrylic intraocular lens (IOL) in cases of posterior capsule rupture during phacoemulsification. Department of Ophthalmology, Ahepa Hospital, Aristotle University Medical School, and Interbalkan Medical Center, Thessaloniki, Greece. This prospective noncomparative case series included 28 eyes (28 patients) having phacoemulsification complicated by extensive posterior capsule rupture with or without vitreous loss. In all eyes, a 3-piece, 6.0 mm optic, foldable acrylic IOL (AcrySof MA60BM, Alcon) was implanted in the sulcus. Postoperative examination included best corrected visual acuity (BCVA), anterior segment biomicroscopy, IOL centralization and position, intraocular pressure (IOP), and fundus biomicroscopy. The follow-up was 6 months. The most common postoperative complications were transient corneal edema in 12 eyes and increased IOP in 11 eyes. Slight asymptomatic decentralization from the center of the pupil (1.0 to 2.0 mm) and pseudophacodonesis were observed in 5 eyes each. Friction of the IOL with the iris occurred in 1 eye. Clinically significant cystoid macular edema occurred in 3 eyes. The final BCVA was between 20/15 and 20/25 in 18 patients, 20/30 in 2, between 20/40 and 20/50 in 4, and between 20/60 and 20/200 in 4. AcrySof IOL implantation in the sulcus during phacoemulsification complicated by posterior capsule rupture preserved the advantages of small-incision surgery. The postoperative behavior and centralization of the IOLs resembled those of poly(methyl methacrylate) lenses.

  3. A classification system of intraocular lens dislocation sites under operating microscopy, and the surgical techniques and outcomes of exchange surgery.

    PubMed

    Hayashi, Ken; Ogawa, Soichiro; Manabe, Shin-Ichi; Hirata, Akira; Yoshimura, Koichi

    2016-03-01

    The aim of this study was to examine the recent status of intraocular lens (IOL) dislocation according to a classification system based on vertical dislocation position, as well as the surgical techniques and outcomes of IOL exchange surgery. The medical records of 230 eyes from 214 consecutive patients who experienced IOL dislocation and underwent exchange surgery between 2006 and 2014 were reviewed. Vertical dislocation sites observed preoperatively under operating microscopy were examined, along with the surgical techniques and outcomes of IOL exchange. Dislocation sites included (1) the anterior chamber (12.2 %), (2) pseudophakodonesis (19.1 %), (3) the anterior vitreous cavity (47.4 %), (4) trap door-like dislocation (dangling in the peripheral vitreous cavity; 16.1 %), and (5) the retinal surface (5.2 %). The IOL retained in the anterior segment was moved onto the iris by pulling it up through the limbal side ports with an anterior vitrectomy (67.8 %), or by pushing it up from the pars plana with an anterior vitrectomy (26.5 %), while the IOL dropped on the retina was lifting it up from the retina after pars plana vitrectomy (5.7 %). Mean uncorrected and distance-corrected visual acuity significantly improved postoperatively (p < 0.0001). Major complications included a marked elevation in intraocular pressure (7.8 %), pupillary capture (6.5 %), and vitreous hemorrhage (2.6 %). Based on the classification system, approximately 95 % of dislocated IOLs were retained in the anterior segment, and these IOLs were exchanged using an anterior approach through limbal incisions with an anterior vitrectomy. Visual acuity improved significantly, and serious complications were uncommon, probably because the IOL exchange techniques were standardized and simplified without pars plana vitrectomy.

  4. The effect of scleral search coil lens wear on the eye

    PubMed Central

    Murphy, P.; Duncan, A.; Glennie, A.; Knox, P.

    2001-01-01

    BACKGROUND/AIM—Scleral search coils are used to measure eye movements. A recent abstract suggests that the coil can affect the eye by decreasing visual acuity, increasing intraocular pressure, and damaging the corneal and conjunctival surface. Such findings, if repeated in all subjects, would cast doubt on the credibility of the search coil as a reliable investigative technique. The aim of this study was to reassess the effect of the scleral search coil on visual function.
METHODS—Six volunteer subjects were selected to undergo coil wear and baseline measurements were taken of logMAR visual acuity, non-contact tonometry, keratometry, and slit lamp examination. Four drops of 0.4% benoxinate hydrochloride were instilled before insertion of the lens by an experienced clinician. The lens then remained on the eye for 30 minutes. Measurements of the four ocular health parameters were repeated after 15 and 30 minutes of lens wear. The lens was then removed and the health of the eye reassessed.
RESULTS—No obvious pattern of change was found in logMAR visual acuity, keratometry, or intraocular pressure. The lens did produce changes to the conjunctival and corneal surfaces, but this was not considered clinically significant.
CONCLUSION—Search coils do not appear to cause any significant effects on visual function. However, thorough prescreening of subjects and post-wear checks should be carried out on all coil wearers to ensure no adverse effects have been caused.

 PMID:11222341

  5. Final incision size after cataract surgery with toric intraocular lens implantation using 2 techniques.

    PubMed

    Guarnieri, Adriano; Moreno-Montañés, Javier; Sabater, Alfonso L; Gosende-Chico, Inmaculada; Bonet-Farriol, Elvira

    2013-11-01

    To analyze the changes in incision sizes after implantation of a toric intraocular lens (IOL) using 2 methods. Department of Ophthalmology, Clínica Universidad de Navarra, Pamplona, Spain. Prospective case series. Coaxial phacoemulsification and IOL implantation through a 2.2 mm clear corneal incision using a cartridge injector were performed. Wound-assisted or cartridge-insertion techniques were used to implant the IOLs. The results were analyzed according to IOL spherical and cylindrical powers. Corneal hysteresis (CH) and the corneal resistance factor (CRF) were measured and evaluated based on the changes in incision size. Incision size increased in 30 (41.7%) of 72 eyes in the wound-assisted group and 71 (98.6%) of 72 eyes in the cartridge-insertion group. The mean incision size after IOL implantation was 2.27 mm ± 0.06 (SD) and 2.37 ± 0.05 mm, respectively (P<.01). The final incision size and IOL spherical power in the wound-assisted technique group (P=.02) and the cartridge-insertion technique group (P=.03) were correlated significantly; IOL toricity was not (P=.19 and P=.28, respectively). The CH and CRF values were not correlated with the final incision size. The final incision size and the changes in incision size after IOL implantation were greater with the cartridge-insertion technique than with the wound-assisted technique. The increase was related to IOL spherical power in both groups but not to IOL toricity. Corneal biomechanical properties were not correlated with the final incision size. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  6. Safety assessment of a new single-use small-incision injector for intraocular lens implantation.

    PubMed

    Satanovsky, Alexandra; Ben-Eliahu, Shmuel; Apple, David J; Kleinmann, Guy

    2011-07-01

    To evaluate the safety of a new injector, the Raysert R-INJ-04/18, for implantation of the C-flex intraocular lens (IOL). Ophthalmology Department, Kaplan Medical Center, Rehovot, Israel. Experimental study. Sixty IOLs were subdivided into 2 equally sized groups. Group A IOLs were injected using the established R-INJ-04 injector, and those in Group B were injected with the new injector. The IOLs were injected into a Petri dish. Subsequently, all IOLs and injectors were evaluated macroscopically and microscopically and then photographed under light microscopy (LM). Two IOLs in each group were randomly chosen and sent for evaluation by scanning electron microscopy (SEM) and energy dispersive analysis of x-ray. All remaining IOLs were sent for power and modulation transfer function (MTF) analysis. All Group B IOLs were successfully injected without evident signs of scratching, cracks, or deposits on LM and SEM examination. In Group A, findings were confined to a singular incidence of a small deposit detected on the periphery of the posterior optical surface of the IOL, with corresponding findings detected on the injector nozzle. No signs of scratching, cracks, or deposits were found in the rest of the IOLs or injectors. The power and MTF analyses were within the normal range for all IOLs. The new 1.8 mm external diameter soft-tipped injector for 2.4 to 2.2 mm incisions was shown to be safe for the implantation of the C-flex 21.0 diopter IOL. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  7. [Effect of ultraviolet radiation on ALDH1 expression in human lens epithelial cells].

    PubMed

    Shi, Jingming; Jia, Songbai; Chen, Xuan; Tang, Luosheng

    2012-06-01

    To determine the apoptosis-inducing effect of ultraviolet light (UV) on human lens epithelial cell (HLEC) and to explore the involvement of changes in ALDH1 folowing UV radiation. HLEC was exposed to the same UV light source and was subsequently divided into 6 groups according to UV radiation time of 0 (control group), 5, 10, 15, and 30 min. Apoptosis was detected by AO/EB staining. Changes of ALDH1 in HLEC were detected by immunohistochemical staining and Western blot. The intensity of immunohistochemical staining and the rate of positive cells decreased with increase of UV time (P<0.05). The rate of positive ALDH1 cells was negatively correlated with the rate of apoptosis (r= -0.92, P<0.05). Western blot showed the integrated absorbance values significantly decreased with the increase of UV time (P<0.05). ALDH1 in HLEC decreases with an increase of UV exposure, which may be related to UV induced apoptosis of HLEC.

  8. Uneventful Anterior Migration of Intravitreal Ozurdex Implant in a Patient with Iris-Sutured Intraocular Lens and Descemet Stripping Automated Endothelial Keratoplasty.

    PubMed

    Zafar, Andleeb; Aslanides, Ioannis M; Selimis, Vasileios; Tsoulnaras, Konstantinos I; Tabibian, David; Kymionis, George D

    2018-01-01

    We report here the case of a patient with anterior segment migration of intravitreal dexamethasone implant as well as its management and outcome. The patient had the following sequence of events: complicated cataract surgery, iris-sutured intraocular lens implant, followed by cystoid macular edema treated with intravitreal Avastin, retinal vein occlusion treated with intravitreal dexamethasone implant, corneal decompensation treated with Descemet stripping automated endothelial keratoplasty (DSAEK), and finally recurrence of macular edema treated with repeated intravitreal dexamethasone implant. Dexamethasone implant had completely dissolved from the eye 12 weeks after insertion without any complication. A conservative approach with regular monitoring in the situation of a quiet anterior segment without any corneal decompensation can provide enough time for the implant to dissolve without causing any complication to the involved eye, avoiding any additional surgical intervention, as presented in this case report. Despite the fact that the implant was left for natural dissolution, there were no adverse effects related to the graft or the eye.

  9. Introduction of a Toric Intraocular Lens to a Non-Refractive Cataract Practice: Challenges and Outcomes

    PubMed Central

    Kirwan, Clare; Nolan, John M; Stack, Jim; Dooley, Ian; Moore, Johnny; Moore, Tara CB; Beatty, Stephen

    2016-01-01

    Aim To identify challenges inherent in introducing a toric intraocular lens (IOL) to a non-refractive cataract practice, and evaluate residual astigmatism achieved and its impact on patient satisfaction. Methods Following introduction of a toric IOL to a cataract practice with all procedures undertaken by a single, non-refractive, surgeon (SB), pre-operative, intra-operative and post-operative data was analysed. Attenuation of anticipated post-operative astigmatism was examined, and subjectively perceived visual functioning was assessed using validated questionnaires. Results Median difference vector (DV, the induced astigmatic change [by magnitude and axis] that would enable the initial surgery to achieve intended target) was 0.93D; median anticipated DV with a non-toric IOL was 2.38D. One eye exhibited 0.75D residual astigmatism, compared to 3.8D anticipated residual astigmatism with a non-toric IOL. 100% of respondents reported satisfaction of ≥ 6/10, with 37.84% of respondents entirely satisfied (10/10). 17 patients (38.63%) reported no symptoms of dysphotopsia (dysphoptosia score 0/10), only 3 respondents (6.8%) reported a clinically meaningful level of dysphotopsia (≥ 4/10). Mean post-operative NEI VF-11 score was 0.54 (+/-0.83; scale 0 – 4). Conclusion Use of a toric IOL to manage astigmatism during cataract surgery results in less post-operative astigmatism than a non-toric IOL, resulting in avoidance of unacceptable post-operative astigmatism. PMID:27830188

  10. Evaluation of an interlaced triple procedure: penetrating keratoplasty, extracapsular cataract extraction, and nonopen-sky intraocular lens implantation.

    PubMed

    Yang, Shuo; Wang, Bin; Zhang, Yangyang; Zhai, Hualei; Wang, Junyi; Wang, Shuang; Xie, Lixin

    2017-09-01

    To evaluate an interlaced triple procedure that involved penetrating keratoplasty (PKP), extracapsular cataract extraction (ECCE) using diathermy capsulotomy, and nonopen-sky intraocular lens (IOL) implantation.This retrospective study involved data from 34 patients who were diagnosed with severe corneal opacities and cataracts. These patients were divided into an interlaced procedure group (21 patients) and a traditional procedure group (13 patients). In the interlaced group, the method of continuous curvilinear capsulorhexis (CCC) was completed via diathermy capsulotomy. The donor corneal button was sutured at 8 positions (at equal intervals) using 10-0 nylon sutures, and the IOL was inserted into the capsular bag using a closed anterior chamber approach at the 10:30 to 12 o'clock positions between the sutures. In the traditional group, CCC was completed using side-port capsular forceps, and the IOL was implanted using an open anterior chamber approach.In the interlaced group, the CCC, open-sky, and total operation times were significantly shorter than in the traditional group (P < .05). Neither the best-corrected visual acuity (BCVA) nor corneal endothelial cell density was significantly different between the groups at 1 and 6 months after the operation.This interlaced triple procedure for the treatment of corneal diseases with cataracts appears to be feasible and practical.

  11. Association of height, body weight, age, and corneal diameter with calculated intraocular lens strength of adult horses.

    PubMed

    Mouney, Meredith C; Townsend, Wendy M; Moore, George E

    2012-12-01

    To determine whether differences exist in the calculated intraocular lens (IOL) strengths of a population of adult horses and to assess the association between calculated IOL strength and horse height, body weight, and age, and between calculated IOL strength and corneal diameter. 28 clinically normal adult horses (56 eyes). Axial globe lengths and anterior chamber depths were measured ultrasonographically. Corneal curvatures were determined with a modified photokeratometer and brightness-mode ultrasonographic images. Data were used in the Binkhorst equation to calculate the predicted IOL strength for each eye. The calculated IOL strengths were compared with a repeated-measures ANOVA. Corneal curvature values (photokeratometer vs brightness-mode ultrasonographic images) were compared with a paired t test. Coefficients of determination were used to measure associations. Calculated IOL strengths (range, 15.4 to 30.1 diopters) differed significantly among horses. There was a significant difference in the corneal curvatures as determined via the 2 methods. Weak associations were found between calculated IOL strength and horse height and between calculated IOL strength and vertical corneal diameter. Calculated IOL strength differed significantly among horses. Because only weak associations were detected between calculated IOL strength and horse height and vertical corneal diameter, these factors would not serve as reliable indicators for selection of the IOL strength for a specific horse.

  12. Accuracy of Corneal Power Measurements for Intraocular Lens Power Calculation after Myopic Laser In situ Keratomileusis.

    PubMed

    Helaly, Hany A; El-Hifnawy, Mohammad A M; Shaheen, Mohamed Shafik; Abou El-Kheir, Amr F

    2016-01-01

    To evaluate the accuracy of corneal power measurements for intraocular lens (IOL) power calculation after myopic laser in situ keratomileusis (LASIK). The study evaluated 45 eyes with a history of myopic LASIK. Corneal power was measured using manual keratometry, automated keratometry, optical biometry, and Scheimflug tomography. Different hypothetical IOL power calculation formulas were performed for each case. The steepest mean K value was measured with manual keratometry (37.48 ± 2.86 D) followed by automated keratometry (37.31 ± 2.83 D) then optical biometry (37.06 ± 2.98 D) followed by Scheimflug tomography (36.55 ± 3.08). None of the K values generated by Scheimflug tomography were steeper than the measurements from the other 3 instruments. Using equivalent K reading (EKR) 4 mm with the Double-K SRK/T formula, the refractive outcome generated 97.8% of cases within ± 2 D, 80.0% of cases within ± 1 D, and 42.2% of cases within ± 0.5 D. The best combination of formulas was "Shammas-PL + Double-K SRK/T formula using EKR 4 mm." Scheimflug tomography imaging using the Holladay EKR 4 mm improved the accuracy of IOL power calculation in post-LASIK eyes. The best option is a combination of formulas. We recommended the use the combined "Shammas-PL ± Double-K SRK/T formula using EKR 4 mm"h for optical outcomes.

  13. Food and Drug Administration study update. One-year results from 671 patients with the 3M multifocal intraocular lens.

    PubMed

    Lindstrom, R L

    1993-01-01

    The clinical evaluation of the Food and Drug Administration study of the 3M diffractive multifocal intraocular lens (IOL) is presented here to demonstrate the results of 1-year postoperative data accumulated for 671 patients, the first of whom received the implant in 1987. Patients were selected for study if they had absence of preoperative pathology, were at least 60 years of age, and had a reasonable postoperative prognosis. Extensive evaluations took place at 4 to 6 months and 12 to 14 months after surgery, including five different visual acuity measurements and contrast sensitivity. All testing was completed on both eyes. Data from the fellow eye served as a control when implanted with a monofocal IOL. Overall uncorrected distance visual acuity at 1 year after surgery shows 57% patients with 20/40 or better acuity. In this same group, 78% achieved J3 or better near vision, which improved to 82% in the best case group. Uncorrected visual acuity of 20/40 or better and J3 or better was achieved by 50% of best case multifocal IOL patients, compared with 26% of the monofocal best case comparison group. Measurements of contrast sensitivity consistently document a small loss, which is considered clinically insignificant. Statistical analysis of satisfaction ratings shows that predictors of satisfaction include uncorrected distance acuity, final near acuity, and fellow eye spherical equivalent. This multifocal lens appears to work very well for most patients, with more than half having functional uncorrected distance and near vision. The study showed several considerations that are important for optimizing clinical performance and patient satisfaction: patient selection, realistic expectations, accurate biometry, and adequate control of surgical procedures.

  14. [Management of post-traumatic aphakia and aniridia: Retrospective study of 17 patients undergoing scleral-sutured artificial iris intraocular lens implantation. Management of aphakia-aniridia with scleral-sutured artificial iris intraocular lenses].

    PubMed

    Villemont, A-S; Kocaba, V; Janin-Manificat, H; Abouaf, L; Poli, M; Marty, A-S; Rabilloud, M; Fleury, J; Burillon, C

    2017-09-01

    To evaluate the long-term outcomes of artificial iris intraocular lenses sutured to the sclera for managing traumatic aphakia and aniridia. All consecutive cases receiving a Morcher ® combination implant from June 2008 to February 2016 in Edouard-Herriot Hospital (Lyon, France) were included in this single-center retrospective study. Visual acuity, subjective degree of glare, quality of life and surgical complications were evaluated. Seventeen eyes of 17 patients were included, among which 82% were male. The mean age was 42 years. The injuries consisted of 23.5% contusion and 70.5% open globe injuries, of which 41% were globe ruptures. There was one postoperative case. A penetrating keratoplasty was performed at the same time for eight eyes. The mean follow-up was 32 months. Best-corrected visual acuity improved in 41.2%, remained the same in 17.6% and decreased in 41.2% of our cases. Distance vision averaged 1±0.25 line better and near vision 2.2±0.32 lines better when visual acuity was quantifiable before surgery. Glare improved in 80% of patients and remained stable in 20%, decreasing on average from 3.3/5 [min. 3-max. 4; SD: 0.48] before surgery to 1.9/5 [min. 0-max. 4; SD: 1.197] after surgery. Regarding the esthetic results, 78% of the patients declared themselves reasonably to very satisfied; 57% reported no limitation of activities of daily living, and 43% reported mild limitation. Ocular hypertension and glaucoma, found in 40% of eyes, were the main postoperative complications. Implantation of prosthetic iris device combined with an intraocular lens appears to be safe and effective in reducing glare disability and improving visual acuity. Close, long-term monitoring is essential for the success of this surgery. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  15. Adaptive Calibration of Dynamic Accommodation—Implications for Accommodating Intraocular Lenses

    PubMed Central

    Schor, Clifton M.; Bharadwaj, Shrikant R.

    2009-01-01

    PURPOSE When the aging lens is replaced with prosthetic accommodating intraocular lenses (IOLs), with effective viscoelasticities different from those of the natural lens, mismatches could arise between the neural control of accommodation and the biomechanical properties of the new lens. These mismatches could lead to either unstable oscillations or sluggishness of dynamic accommodation. Using computer simulations, we investigated whether optimal accommodative responses could be restored through recalibration of the neural control of accommodation. Using human experiments, we also investigated whether the accommodative system has the capacity for adaptive recalibration in response to changes in lens biomechanics. METHODS Dynamic performance of two accommodating IOL prototypes was simulated for a 45-year-old accommodative system, before and after neural recalibration, using a dynamic model of accommodation. Accommodating IOL I, a prototype for an injectable accommodating IOL, was less stiff and less viscous than the natural 45-year-old lens. Accommodating IOL II, a prototype for a translating accommodating IOL, was less stiff and more viscous than the natural 45-year-old lens. Short-term adaptive recalibration of dynamic accommodation was stimulated using a double-step adaptation paradigm that optically induced changes in neuromuscular effort mimicking responses to changes in lens biomechanics. RESULTS Model simulations indicate that the unstable oscillations or sluggishness of dynamic accommodation resulting from mismatches between neural control and lens biomechanics might be restored through neural recalibration. CONCLUSIONS Empirical measures reveal that the accommodative system is capable of adaptive recalibration in response to optical loads that simulate effects of changing lens biomechanics. PMID:19044245

  16. Effect of posterior corneal astigmatism on refractive outcomes after toric intraocular lens implantation.

    PubMed

    Zhang, Lijun; Sy, Mary Ellen; Mai, Harry; Yu, Fei; Hamilton, D Rex

    2015-01-01

    To compare the prediction error after toric intraocular lens (IOL) (Acrysof IQ) implantation using corneal astigmatism measurements obtained with an IOLMaster automated keratometer and a Galilei dual rotating camera Scheimpflug-Placido tomographer. Jules Stein Eye Institute, University of California Los Angeles, Los Angeles, California, USA. Retrospective case series. The predicted residual astigmatism after toric IOL implantation was calculated using preoperative astigmatism values from an automated keratometer and the total corneal power (TCP) determined by ray tracing through the measured anterior and posterior corneal surfaces using dual Scheimpflug-Placido tomography. The prediction error was calculated as the difference between the predicted astigmatism and the manifest astigmatism at least 1 month postoperatively. The calculations included vector analysis. The study evaluated 35 eyes (35 patients). The preoperative corneal posterior astigmatism mean magnitude was 0.33 diopter (D) ± 0.16 (SD) (vector mean 0.23 × 176). Twenty-six eyes (74.3%) had with-the-rule (WTR) posterior astigmatism. The postoperative manifest refractive astigmatism mean magnitude was 0.38 ± 0.18 D (vector mean 0.26 × 171). There was no statistically significant difference in the mean magnitude prediction error between the automated keratometer and TCP techniques. However, the automated keratometer method tended to overcorrect WTR astigmatism and undercorrect against-the-rule (ATR) astigmatism. The TCP technique lacked these biases. The automated keratometer and TCP methods for estimating the magnitude of corneal astigmatism gave similar results. However, the automated keratometer method tended to overcorrect WTR astigmatism and undercorrect ATR astigmatism. Dr. Hamilton has received honoraria for educational lectures from Ziemer Ophthalmic Systems. No other author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published

  17. Outcomes of 23- and 25-gauge transconjunctival sutureless vitrectomies for dislocated intraocular lenses.

    PubMed

    Bajgai, Priya; Tigari, Basavraj; Singh, Ramandeep

    2017-10-04

    To compare the outcome of 23-gauge as compared with 25-gauge transconjunctival sutureless vitrectomy (TSV) in the management of dislocated intraocular lenses (IOLs). Retrospective, non-consecutive, comparative, interventional case series. Patients with dislocated intraocular lens who underwent sutureless PPV using either 23-gauge or 25-gauge instruments. The patients who presented with a dislocated IOL, underwent TSV with repositioning of the intraocular lens, either in the sulcus or scleral-fixated sutured/glued. Of the total 61 eyes, 33 (54.09%) underwent 23-gauge TSV and 28 (45.90%) underwent 25-gauge TSV. The mean logMAR BCVA at baseline and 6 months after surgery was 0.8 and 0.46 in the 23-gauge group, and 0.82 and 0.47 in the 25-gauge group. There was no significant difference in logMAR BCVA values between the two groups at any time point of time during the follow-up. The mean postoperative IOP on postoperative day 1 was 14.76 ± 5.4 in 23-gauge group and 17.57 ± 7.9 in the 25-gauge group (p = 0.10). Retinal break was noticed intraoperatively in two cases in 23-gauge group and in three cases in 25-gauge group (p = 0.509). Postoperative complications included IOL decentration in one case of 23-gauge vitrectomy and two cases in 25-gauge group (p = 0.5), cystoid macular edema in four patients in 23-gauge group and six cases of 25-gauge group (p = 0.3) and retinal detachment in one case in each group (p = 0.9). 25-gauge appears to be as safe and as effective as 23-gauge TSV in the management of dislocated intraocular lenses.

  18. Dynamics of defects in Ce³⁺ doped silica affecting its performance as protective filter in ultraviolet high-power lasers.

    PubMed

    Demos, Stavros G; Ehrmann, Paul R; Qiu, S Roger; Schaffers, Kathleen I; Suratwala, Tayyab I

    2014-11-17

    We investigate defects forming in Ce³⁺-doped fused silica samples following exposure to nanosecond ultraviolet laser pulses and their relaxation as a function of time and exposure to low intensity light at different wavelengths. A subset of these defects are responsible for inducing absorption in the visible and near infrared spectral range, which is of critical importance for the use of this material as ultraviolet light absorbing filter in high power laser systems. The dependence of the induced absorption as a function of laser fluence and methods to most efficiently mitigate this effect are presented. Experiments simulating the operation of the material as a UV protection filter for high power laser systems were performed in order to determine limitations and practical operational conditions.

  19. Spectral transmission of the human crystalline lens in adult and elderly persons: color and total transmission of visible light.

    PubMed

    Artigas, Jose M; Felipe, Adelina; Navea, Amparo; Fandiño, Adriana; Artigas, Cristina

    2012-06-26

    To experimentally measure the spectral transmission of human crystalline lenses belonging to adult and elderly persons, and to determine the color and total transmission of visible light of such crystalline lenses. The spectral transmission curve of 32 human crystalline lenses was measured using a PerkinElmer 800UV/VIS spectrometer. Total transmission of visible light and the chromatic coordinates of these crystalline lenses were determined from these curves for solar illumination. The crystalline lens that filters UV and its transmission in the visible spectrum decreases with age; such a decrease is greater for short wavelengths. The total transmission of visible light decreases, especially after the age of 70 years, and the crystalline color becomes yellower and saturated. The great variability existing in the spectral transmission of the human crystalline lens is lesser between the ages of 40 and 59 years, but greater from the age of 60 and older. The decrement in transmittance between these two age groups varies from 40% for 420 nm to 18% for 580 nm. Nevertheless, it is proven that age is not the only parameter affecting crystalline transmission. In the range of 40 to 59 years, age does not bear an influence on total transmission of light, but from 60 years and older it does. Moreover, the light transmitted decreases with age. This total transmission of light is similar to or lower than the amount that the different intraocular lenses transmit, even with a yellow or orange filter. The color of the human lens becomes yellowish and saturated with age.

  20. Quantification of the ultraviolet radiation (UVR) field in the human eye in vivo using novel instrumentation and the potential benefits of UVR blocking hydrogel contact lens

    PubMed Central

    Walsh, J.; Bergmanson, J.; Wallace, D.; Saldana, G.; Dempsey, H.; McEvoy, H.; Collum, L.

    2001-01-01

    BACKGROUND/AIMS—Certain degenerative eye conditions occur predominantly nasally, at the limbal region, and are associated with solar ultraviolet radiation (UVR) induced damage. The relative contribution to the in vivo ocular flux of (a) the reflection of UVR incident on the skin of the nose onto the nasal limbus, and (b) the focusing of UVR incident on the temporal side of the cornea onto the nasal limbus were examined.
METHODS—A novel photodiode sensor array was used to measure the UVR field across the eye. In addition, a novel spectrometer set-up was used to measure the spectrum of radiation refracted across the cornea. The efficacy of UVR blocking hydrogel contact lenses in filtering incident UVR was assessed in vivo.
RESULTS—Qualitative and quantitative data indicated an increase nasally of UVR. Photodiode readings showed a net UVR increase from the temporal to the nasal side. Transmission curves showed that most UVR incident on the limbal region is either absorbed by, or transmitted through, the ocular tissues. This radiation is filtered by UVR blocking soft contact lens.
CONCLUSIONS—An increased UVR flux on the nasal side of the eye, due to reflection off the nasal skin, was identified in vivo. Any UVR passing through the cornea is either absorbed by the conjunctiva and/or transmitted through it onto the sclera where it is absorbed. UVR blocking hydrogel contact lenses can eliminate these sources of UVR.

 PMID:11520761

  1. Comparison of Visual Quality after Implantation of Big Bag and Akreos Adapt Intraocular Lenses in Patients with High Myopia.

    PubMed

    Ma, Shengsheng; Zheng, Dongjian; Lin, Ling; Meng, Fanjian; Yuan, Yonggang

    2015-03-01

    To compare vision quality following phacoemulsification cataract extraction and implantation of a Big Bag or Akreos Adapt intraocular lens (IOL) in patients diagnosed with high myopia complicated with cataract. This was a randomized prospective control study. The patients with high myopia. complicated with cataract, with axial length ≥ 28 mm, and corneal astigmatism ≤ 1D were enrolled and randomly divided into the Big Bag and Akreos Adapt IOL groups. All patients underwent phacoemulsification cataract extraction and lens implantation. At 3 months after surgery, intraocular high-order aberration was measured by a Tracey-iTrace wavefront aberrometer at a pupil diameter of 5 mm in an absolutely dark room and statistically compared between two groups. The images of the anterior segment of eyes were photographed with a Scheimpflug camera using Penta-cam three-dimensional anterior segment analyzer. The tilt and decentration of the IOL were calculated by Image-pro plus 6.0 imaging analysis software and statistically compared between two groups. In total, 127 patients (127 eyes), including 52 males and 75 females, were enrolled in this study. The total high-order aberration and coma in the Akreos Adapt group (59 eyes) were significantly higher compared with those in the Big Bag (P < 0.05). The clover and spherical aberration did not differ between the two groups (P > 0.05). The horizontal and vertical decentration were significantly smaller in the Big Bag lens group than in the Akreos Adapt group (both P < 0.05), whereas the tilt of IOL did not significantly differ between the two groups (P > 0.05). Both Big Bag and Akreos Adapt IOLs possess relatively good intraocular stability implanted in patients with high myopia. Compared with the Akreos Adapt IOL, the Big Bag IOL presents with smaller intraocular high-order aberration. Coma is the major difference between the two groups.

  2. Microincision Hydrophobic Acrylic Aspheric Toric Intraocular Lens for Astigmatism and Cataract Correction.

    PubMed

    Bissen-Miyajima, Hiroko; Negishi, Kazuno; Hieda, Osamu; Kinoshita, Shigeru

    2015-06-01

    To evaluate the efficacy and safety of a new acrylic one-piece toric intraocular lens (IOL). This prospective multicenter clinical trial included 93 eyes of 61 patients that were implanted with a hydrophobic acrylic toric IOL from 2010 to 2012 and followed for 1 year. This IOL uses the platform of a microincision one-piece aspheric IOL, the NY-60 IOL (HOYA, Tokyo, Japan), with three increments in cylindrical power (NHT15, 1.5 diopters [D]; NHT23, 2.25 D; and NHT30, 3.0 D). The inclusion criterion was preoperative corneal astigmatism from 0.75 to 3.00 D. The primary endpoint was uncorrected distance visual acuity (UDVA) of 0.0 logMAR (20/20 Snellen) or better 6 months postoperatively. In addition to UDVA, corrected distance visual acuity (CDVA), residual astigmatism, stability of the IOL alignment, need of realignment, and the rate of Nd:YAG laser capsulotomy were evaluated up to 1 year postoperatively. Errors in astigmatic correction were assessed using Alpin's vector analysis. The primary endpoint was achieved in 54.8% of eyes. One year postoperatively, the logMAR UDVAs were 0.02 ± 0.13, 0.05 ± 0.17, and 0.09 ± 0.14 with models NHT15, NHT23, and NHT30, which corresponds to 0.96 (19/20 Snellen), 0.89 (18/20 Snellen), and 0.82 (16/20 Snellen), respectively. One year postoperatively, the residual astigmatism was 0.66 ± 0.58 D. In each evaluation, the mean absolute change in the position of the axis mark was between 1.93° and 2.32°. Three eyes required repositioning of the IOL axis and 2 eyes received Nd:YAG laser capsulotomy. The correction error showed an undercorrection with against-the-rule astigmatism and overcorrection with with-the-rule astigmatism. The new one-piece toric IOL provided desirable clinical outcomes and stability in eyes with corneal astigmatism. Copyright 2015, SLACK Incorporated.

  3. Simulation of Blast Loading on an Ultrastructurally-based Computational Model of the Ocular Lens

    DTIC Science & Technology

    2015-10-01

    cells) is stressed by the passing shock wave. Traumatic cataract can result in a partially or fully clouded lens, complete dislo- cation of the lens...penetration by Intra-Ocular Foreign Bodies (IOFBs), but also shock propagation and solid-fluid interaction be- tween the lens and vitreous and aqueous...1040-8738. doi: 10.1097/ICU.0b013e3283140e98. T.Y. Wong, M.B. Seet, and C.L. Ang. Eye injuries in twentieth century warfare: A historical perspective. Survey of Ophthalmology, 41(6):433–459, MAY-JUN 1997. ISSN 0039-6257. i

  4. Transcriptional activity of detoxification genes is altered by ultraviolet filters in Chironomus riparius.

    PubMed

    Martínez-Guitarte, José-Luis

    2018-03-01

    Ultraviolet (UV) filters are compounds used to prevent the damage produced by UV radiation in personal care products, plastics, etc. They have been associated with endocrine disruption, showing anti-estrogen activity in vertebrates and altering the ecdysone pathway in invertebrates. Although they have attracted the attention of multiple research teams there is a lack of data about how animals activate detoxification systems, especially in invertebrates. Here, analysis of the effects of two UV filters, benzophenone-3 (BP3) and 4-methylbenzylidene camphor (4MBC), on the transcriptional activity of nine genes covering the three steps of the detoxification process has been performed. Four cytochrome P450 genes belonging to different members of this family, five GST genes, and the multidrug resistance protein 1 (MRP1) gene were studied by RT-PCR to analyze their transcriptional activity in fourth instar larvae exposed to the UV filters for 8 and 24h. The obtained results show a differential response with downregulation of the different Cyp450s tested by 4MBC while BP3 seems not to modify their expression. On the other hand, some of the GST genes were affected by one or other of the filters, showing a less homogenous response. Finally, MRP1 was activated by both filters but at different times. These results demonstrate for first time that UV filters alter the expression of genes involved in the different steps of the detoxification process and that they can be processed by phase I enzymes other than Cyp450s. They also suggest that UV filters affect biotransformation processes, compromising the ability of the individual to respond to chemical stress, so further research is needed to know the extent of the damage that they can produce in the resistance of the cell to chemicals. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Characterization of a smartphone camera's response to ultraviolet A radiation.

    PubMed

    Igoe, Damien; Parisi, Alfio; Carter, Brad

    2013-01-01

    As part of a wider study into the use of smartphones as solar ultraviolet radiation monitors, this article characterizes the ultraviolet A (UVA; 320-400 nm) response of a consumer complementary metal oxide semiconductor (CMOS)-based smartphone image sensor in a controlled laboratory environment. The CMOS image sensor in the camera possesses inherent sensitivity to UVA, and despite the attenuation due to the lens and neutral density and wavelength-specific bandpass filters, the measured relative UVA irradiances relative to the incident irradiances range from 0.0065% at 380 nm to 0.0051% at 340 nm. In addition, the sensor demonstrates a predictable response to low-intensity discrete UVA stimuli that can be modelled using the ratio of recorded digital values to the incident UVA irradiance for a given automatic exposure time, and resulting in measurement errors that are typically less than 5%. Our results support the idea that smartphones can be used for scientific monitoring of UVA radiation. © 2012 Wiley Periodicals, Inc. Photochemistry and Photobiology © 2012 The American Society of Photobiology.

  6. Vision in semi-aquatic snakes: Intraocular morphology, accommodation, and eye: Body allometry

    NASA Astrophysics Data System (ADS)

    Plylar, Helen Bond

    Vision in vertebrates generally relies on the refractive power of the cornea and crystalline lens to facilitate vision. Light from the environment enters the eye and is refracted by the cornea and lens onto the retina for production of an image. When an animal with a system designed for air submerges underwater, the refractive power of the cornea is lost. Semi-aquatic animals (e.g., water snakes, turtles, aquatic mammals) must overcome this loss of corneal refractive power through visual accommodation. Accommodation relies on change of the position or shape of the lens to change the focal length of the optical system. Intraocular muscles and fibers facilitate lenticular displacement and deformation. Snakes, in general, are largely unstudied in terms of visual acuity and intraocular morphology. I used light microscopy and scanning electron microscopy to examine differences in eye anatomy between five sympatric colubrid snake species (Nerodia cyclopion, N. fasciata, N. rhombifer, Pantherophis obsoletus, and Thamnophis proximus) from Southeast Louisiana. I discovered previously undescribed structures associated with the lens in semi-aquatic species. Photorefractive methods were used to assess refractive error. While all species overcame the expected hyperopia imposed by submergence, there was interspecific variation in refractive error. To assess scaling of eye size with body size, I measure of eye size, head size, and body size in Nerodia cyclopion and N. fasciata from the SLU Vertebrate Museum. In both species, body size increases at a significantly faster rate than head size and eye size (negative allometry). Small snakes have large eyes relative to body size, and large snakes have relatively small eyes. There were interspecific differences in scaling of eye size with body size, where N. fasciata had larger eye diameter, but N. cyclopion had longer eyes (axial length).

  7. Evaluation of a new soft tipped injector for the implantation of foldable intraocular lenses.

    PubMed

    Kleinmann, Guy; Apple, David J

    2007-08-01

    To evaluate the R-INJ-04 soft-tipped injector, a new injector with an integral round nozzle manufactured by Rayner Intraocular Lenses, England. 16 Rayner C-flex intraocular lenses (IOLs; Rayner Intraocular lenses, England) ranging between +10 and +30 D (2 for each power) were tested. An ophthalmic viscoelastic device (Healon, AMO, Santa Ana, California, USA) was applied to the injectors. The IOLs were loaded according to the company injector's instructions for use and were injected into a Petri dish. After the injection, all the IOLs and nozzles were evaluated by gross (macroscopic) and microscopic analyses and photographed under a light microscope. One lens of each power and the cartridge used for the implantation were then sent for further analysis by scanning electron microscopy (SEM). The rest of the IOLs were tested for power and modulation transfer function (MTF). All the injections were successful. No damage to the IOLs or to the injectors was found by gross examination, light microscopy and SEM. No deposits were found on the IOL optical surfaces or haptics. Power and MTF analysis showed a close match with the original measurements. Our results suggest that the R-INJ-04 soft-tipped injector is safe for the implantation of the C-flex IOL with power range from 10 to 30 D. No structural damage to the IOLs or to the injectors was found, and the lens power and light transmission properties were not damaged in any way by the injection process.

  8. Posterior chamber phakic intraocular lens implantation: comparative, multicentre study in 351 eyes with low-to-moderate or high myopia.

    PubMed

    Kamiya, Kazutaka; Shimizu, Kimiya; Igarashi, Akihito; Kitazawa, Yoshihiro; Kojima, Takashi; Nakamura, Tomoaki; Oka, Yoshitaka; Matsumoto, Rei

    2018-02-01

    To compare the clinical outcomes of posterior chamber phakic intraocular lens implantation with a central hole (Hole Implantable Collamer Lens (ICL), STAAR Surgical) for low-to-moderate myopia and for high myopia. This multicentre retrospective case series comprised 351 eyes of 351 consecutive patients undergoing ICL implantation. Eyes were divided into groups based on preoperative degree of myopia: group 1; 57 eyes, manifest spherical equivalent less than -6 dioptres (D), and group 2; 294 eyes, -6 D or more. Safety, efficacy, predictability, stability and adverse events were compared preoperatively; and at 1 day, 1 week and 1, 3, 6 and 12 months postoperatively, RESULTS: Uncorrected and corrected visual acuities were -0.17±0.14 and -0.21±0.10 logMAR in group 1, and -0.16±0.09 and -0.21±0.08 logMAR in group 2, 1 year postoperatively. In groups 1 and 2, 98% and 99% of eyes were within 1.0 D of the targeted correction. Manifest refraction changes of -0.12±0.34 D (group 1) and -0.18±0.43 D (group 2) occurred from 1 day to 1 year. ICL exchanges were necessary in two eyes (0.7%) in group 2. No vision-threatening complications occurred at any time. The ICL performed well for the correction of both low-to-moderate myopia and high myopia throughout the 1-year observation period. The clinical outcomes of ICL implantation for low-to-moderate myopia are essentially equivalent to those for high myopia. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  9. Light-distortion analysis as a possible indicator of visual quality after refractive lens exchange with diffractive multifocal intraocular lenses.

    PubMed

    Brito, Pedro; Salgado-Borges, José; Neves, Helena; Gonzalez-Meijome, José; Monteiro, Manuel

    2015-03-01

    To study the perception of light distortion after refractive lens exchange (RLE) with diffractive multifocal intraocular lenses (IOLs). Clínica Oftalmológica das Antas, Porto, Portugal. Retrospective comparative study. Refractive lens exchange was performed with implantation of an AT Lisa 839M (trifocal) or 909MP (bifocal toric) IOL, the latter if corneal astigmatism was more than 0.75 diopter (D). The postoperative visual and refractive outcomes were evaluated. A prototype light-distortion analyzer was used to quantify the postoperative light-distortion indices. A control group of eyes in which a Tecnis ZCB00 1-piece monofocal IOL was implanted had the same examinations. A trifocal or bifocal toric IOL was implanted in 66 eyes. The control IOL was implanted in 18 eyes. All 3 groups obtained a significant improvement in uncorrected distance visual acuity (UDVA) (P < .001) and corrected distance visual acuity (CDVA) (P = .001). The mean uncorrected near visual acuity (UNVA) was 0.123 logMAR with the trifocal IOL and 0.130 logMAR with the bifocal toric IOL. The residual refractive cylinder was less than 1.00 D in 86.7% of cases with the toric IOL. The mean light-distortion index was significantly higher in the multifocal IOL groups than in the monofocal group (P < .001), although no correlation was found between the light-distortion index and CDVA. The multifocal IOLs provided excellent UDVA and functional UNVA despite increased light-distortion indices. The light-distortion analyzer reliably quantified a subjective component of vision distinct from visual acuity; it may become a useful adjunct in the evaluation of visual quality obtained with multifocal IOLs. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  10. Small-incision 4-point scleral suture fixation of a foldable hydrophilic acrylic intraocular lens in the absence of capsule support.

    PubMed

    Terveen, Daniel C; Fram, Nicole R; Ayres, Brandon; Berdahl, John P

    2016-02-01

    To determine the visual outcomes and complications of a new small-incision technique for 4-point fixation of a hydrophilic acrylic posterior chamber intraocular lens (IOL) in the absence of capsule support. Three North American tertiary referral centers and a private practice. Retrospective case series. Secondary IOL placement was performed from 2011 to 2014. Indications for surgery, clinical results, and complications were analyzed. Primary outcomes included postoperative corrected distance visual acuity (CDVA) and surgical complications. Charts of 35 patients (37 eyes) were reviewed. The mean age at surgery was 56 years, and the mean follow-up was 6 months (range 3 to 24 months). Clinical indications included a dislocated IOL (30%), ocular trauma (19%), crystalline lens subluxation (19%), uveitis-glaucoma-hyphema syndrome (5%), post-complicated cataract (8%), congenital cataract (8%), and decompensated cornea (3%). The mean CDVA improved from 20/80 preoperatively to 20/40 postoperatively (P < .01). Thirty-six eyes (97%) had an improved or unchanged CDVA, and 1 eye (3%) had a reduced CDVA because of worsening glaucoma. Postoperative complications included ocular hypertension (24%), iritis (5%), wound leakage (3%), transient corneal edema (3%), glaucoma requiring a tube shunt (3%), and IOL dislocation (3%). Small-incision 4-point scleral fixation of the Akreos AO60 hydrophilic acrylic IOL in the absence of capsule support appears to be a safe and effective technique for secondary IOL placement. Drs. Berdahl and Ayres are consultants to Bausch & Lomb, Inc. Drs. Ayres and Fram have received speaker fees from Bausch & Lomb. Dr. Terveen does not have a financial or proprietary interest in any material or methods mentioned. Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  11. Implantation of ArtificialIris, a CustomFlex irisprosthesis, in a trauma patient with an Artisan lens

    PubMed Central

    Doroodgar, Farideh; Jabbarvand, Mahmoud; Niazi, Feizollah; Niazi, Sana; Sanginabadi, Azad

    2017-01-01

    Abstract Purpose: To evaluate probable complications of ArtificialIris implantation with iris fixated intraocular lens. Method: Development of photophobia, glare, and psychological strain during face-to-face communication in a 23-year-old man with a widespread traumatic iris defect terminate to make a decision for performing implantation of an ArtificialIris (Humanoptics, Erlangen, Germany) under the remnant iris without removing the patient's existing Artisan lens. Results: Without any intraoperative or postoperative complications, the patient's visual acuity increased by 1 line, the endothelial cell loss was comparable with the cell loss associated with standard cataract surgery, and the anterior-chamber depth and anterior-chamber anatomy did not change. At the final follow-up examination, the mean intraocular pressure did not differ from baseline, and we achieved high level of patient satisfaction and subjective vision improvement. We discuss the particular importance of considering the patient's expectations, the appropriate measurements, ways to perfect color evaluation, and the types of ArtificialIris products. Conclusion: The implantation of the ArtificialIris in patients with aphakic iris-supported lenses (ie, pre-existing Artisan lenses) is a feasible approach and a useful option for patients with thin irises and iris hypoplasia who are at risk of subluxation or the dislocation of the posterior-chamber intraocular lens (PCIOL), and also those with sclerally fixed PCIOLs. PMID:29137026

  12. Uneventful Anterior Migration of Intravitreal Ozurdex Implant in a Patient with Iris-Sutured Intraocular Lens and Descemet Stripping Automated Endothelial Keratoplasty

    PubMed Central

    Zafar, Andleeb; Aslanides, Ioannis M.; Selimis, Vasileios; Tsoulnaras, Konstantinos I.; Tabibian, David; Kymionis, George D.

    2018-01-01

    Purpose We report here the case of a patient with anterior segment migration of intravitreal dexamethasone implant as well as its management and outcome. Methods The patient had the following sequence of events: complicated cataract surgery, iris-sutured intraocular lens implant, followed by cystoid macular edema treated with intravitreal Avastin, retinal vein occlusion treated with intravitreal dexamethasone implant, corneal decompensation treated with Descemet stripping automated endothelial keratoplasty (DSAEK), and finally recurrence of macular edema treated with repeated intravitreal dexamethasone implant. Results Dexamethasone implant had completely dissolved from the eye 12 weeks after insertion without any complication. Conclusion A conservative approach with regular monitoring in the situation of a quiet anterior segment without any corneal decompensation can provide enough time for the implant to dissolve without causing any complication to the involved eye, avoiding any additional surgical intervention, as presented in this case report. Despite the fact that the implant was left for natural dissolution, there were no adverse effects related to the graft or the eye. PMID:29643797

  13. Rapid analysis of ultraviolet filters using dispersive liquid-liquid microextraction coupled to headspace gas chromatography and mass spectrometry.

    PubMed

    Pierson, Stephen A; Trujillo-Rodríguez, María J; Anderson, Jared L

    2018-05-29

    An ionic-liquid-based in situ dispersive liquid-liquid microextraction method coupled to headspace gas chromatography and mass spectrometry was developed for the rapid analysis of ultraviolet filters. The chemical structures of five ionic liquids were specifically designed to incorporate various functional groups for the favorable extraction of the target analytes. Extraction parameters including ionic liquid mass, molar ratio of ionic liquid to metathesis reagent, vortex time, ionic strength, pH, and total sample volume were studied and optimized. The effect of the headspace temperature and volume during the headspace sampling step was also evaluated to increase the sensitivity of the method. The optimized procedure is fast as it only required ∼7-10 min per extraction and allowed for multiple extractions to be performed simultaneously. In addition, the method exhibited high precision, good linearity, and low limits of detection for six ultraviolet filters in aqueous samples. The developed method was applied to both pool and lake water samples attaining acceptable relative recovery values. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Characteristics of the retinal images of the eye optical systems with implanted intraocular lenses

    NASA Astrophysics Data System (ADS)

    Siedlecki, Damian; Zając, Marek; Nowak, Jerzy

    2007-04-01

    Cataract, or opacity of crystalline lens in the human eye is one of the most frequent reasons of blindness nowadays. Removing the pathologically altered crystalline lens and replacing it with artificial implantable intraocular lens (IOL) is practically the only therapy in this illness. There exist a wide variety of artificial IOL types on the medical market, differing in their material and design (shape). In this paper six exemplary models of IOL's made of PMMA, acrylic and silicone are considered. The retinal image quality is analyzed numerically on the basis of Liou-Brennan eye model with these IOL's inserted. Chromatic aberration as well as polychromatic Point Spread Function and Modulation Transfer Function are calculated as most adequate image quality measures. The calculations made with Zemax TM software show the importance of chromatic aberration correction.

  15. Effect of astigmatism on visual acuity in eyes with a diffractive multifocal intraocular lens.

    PubMed

    Hayashi, Ken; Manabe, Shin-Ichi; Yoshida, Motoaki; Hayashi, Hideyuki

    2010-08-01

    To examine the effect of astigmatism on visual acuity at various distances in eyes with a diffractive multifocal intraocular lens (IOL). Hayashi Eye Hospital, Fukuoka, Japan. In this study, eyes had implantation of a diffractive multifocal IOL with a +3.00 diopter (D) addition (add) (AcrySof ReSTOR SN6AD1), a diffractive multifocal IOL with a +4.00 D add (AcrySof ReSTOR SN6AD3), or a monofocal IOL (AcrySof SN60WF). Astigmatism was simulated by adding cylindrical lenses of various diopters (0.00, 0.50, 1.00, 1.50, 2.00), after which distance-corrected acuity was measured at various distances. At most distances, the mean visual acuity in the multifocal IOL groups decreased in proportion to the added astigmatism. With astigmatism of 0.00 D and 0.50 D, distance-corrected near visual acuity (DCNVA) in the +4.00 D group and distance-corrected intermediate visual acuity (DCIVA) and DCNVA in the +3.00 D group were significantly better than in the monofocal group; the corrected distance visual acuity (CDVA) was similar. The DCNVA with astigmatism of 1.00 D was better in 2 multifocal groups; however, with astigmatism of 1.50 D and 2.00 D, the CDVA and DCIVA at 0.5m in the multifocal groups were significantly worse than in the monofocal group, although the DCNVA was similar. With astigmatism of 1.00 D or greater, the mean CDVA and DCNVA in the multifocal groups reached useful levels (20/40). The presence of astigmatism in eyes with a diffractive multifocal IOL compromised all distance visual acuities, suggesting the need to correct astigmatism of greater than 1.00 D. No author has a financial or proprietary interest in any material or method mentioned. Copyright 2010 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  16. Image-guided system versus manual marking for toric intraocular lens alignment in cataract surgery.

    PubMed

    Webers, Valentijn S C; Bauer, Noel J C; Visser, Nienke; Berendschot, Tos T J M; van den Biggelaar, Frank J H M; Nuijts, Rudy M M A

    2017-06-01

    To compare the accuracy of toric intraocular lens (IOL) alignment using the Verion Image-Guided System versus a conventional manual ink-marking procedure. University Eye Clinic Maastricht, Maastricht, the Netherlands. Prospective randomized clinical trial. Eyes with regular corneal astigmatism of at least 1.25 diopters (D) that required cataract surgery and toric IOL implantation (Acrysof SN6AT3-T9) were randomly assigned to the image-guided group or the manual-marking group. The primary outcome was the alignment of the toric IOL based on preoperative images and images taken immediately after surgery. Secondary outcome measures were residual astigmatism, uncorrected distance visual acuity (UDVA), and complications. The study enrolled 36 eyes (24 patients). The mean toric IOL misalignment was significantly less in the image-guided group than in the manual group 1 hour (1.3 degrees ± 1.6 [SD] versus 2.8 ± 1.8 degrees; P = .02) and 3 months (1.7 ± 1.5 degrees versus 3.1 ± 2.1 degrees; P < .05) postoperatively. The mean residual refractive cylinder was -0.36 ± 0.32 D and -0.47 ± 0.28 D in the image-guided group and manual group, respectively (P > .05). The mean UDVA was 0.03 ± 0.10 logarithm of minimum angle of resolution (logMAR) and 0.04 ± 0.09 logMAR, respectively (both P > .05). No intraoperative complications occurred during any surgery. The IOL misalignment was significantly less with digital marking than with manual marking; this did not result in a better UDVA or lower residual refractive astigmatism. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  17. Comparison of intraocular lens decentration and tilt measurements using 2 Purkinje meter systems.

    PubMed

    Maedel, Sophie; Hirnschall, Nino; Bayer, Natascha; Markovic, Sabine; Tabernero, Juan; Artal, Pablo; Schaeffel, Frank; Findl, Oliver

    2017-05-01

    To evaluate the difference in intraocular lens tilt and decentration measurements with 2 Purkinje meters. Vienna Institute for Research in Ocular Surgery, Hanusch Hospital, Vienna, Austria. Prospective evaluation of diagnostic test. This single-center study included pseudophakic patients in 2 substudies in which 3 consecutive measurements were performed with 2 Purkinje meters (Spanish and German). In substudy 1, an inexperienced examiner performed all measurements after a short learning period. In substudy 2, all measurements were taken by experienced examiners under direct supervision of the inventors of the devices. Substudy 1 included 53 pseudophakic eyes in which all 53 scans were successful with the Spanish device; however, only 35 measurements (66%) were successful with the German Purkinje meter. The mean tilt measured with the Spanish Purkinje meter was 4.35 degrees ± 2.50 (SD) and 9.20 ± 6.96 degrees with the German Purkinje meter. The mean decentration was 0.44 ± 0.19 mm and 0.74 ± 0.91 mm, (P = .44), respectively. In substudy 2 (29 pseudophakic eyes), the number of successful scans was 29 (100%) and 18 (62%) for the Spanish meter and German Purkinje meter, respectively. The mean horizontal and vertical tilt difference vector between the 2 systems was 4.89 ± 3.24 degrees and 7.57 ± 3.82 degrees, respectively. Concerning clinical feasibility, the Spanish Purkinje meter had a greater percentage of successful scans than the German device. In addition, this device measured significantly higher tilt values than the Spanish Purkinje meter. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  18. Investigating the impact of preoperative corneal astigmatism orientation on the postoperative spherical equivalent refraction following intraocular lens implantation.

    PubMed

    McNeely, Richard N; Moutari, Salissou; Pazo, Eric; Moore, Jonathan E

    2018-01-01

    To investigate the impact of the orientation of preoperative corneal astigmatism on achieving the postoperative target refraction following monofocal intraocular lens (IOL) implantation. This study enrolled 339 eyes who had uneventful cataract surgery or refractive lens exchange (RLE) with subsequent monofocal IOL implantation. Eyes were initially categorized dependent upon axial length and then on the orientation of preoperative anterior corneal astigmatism. Group 1 had against-the-rule (ATR) anterior corneal astigmatism, group 2 had with-the-rule (WTR) anterior corneal astigmatism, and group 3 had oblique (OB) anterior corneal astigmatism. The preoperative corneal astigmatism was determined by the IOLMaster (Carl Zeiss Meditec AG). Postoperative refraction was completed for all eyes, and the results were calculated and compared for the separate groups. In eyes with axial lengths greater than 22.0 mm and less than 25.0 mm there was a significant difference between the magnitude of preoperative corneal astigmatism between groups 2 and 3 with 0.827 ± 0.376 D in group 2, and 0.677 ± 0.387 D in group 3. The mean postoperative spherical equivalent (SE) prediction error was - 0.132 ± 0.475 D in group 1, 0.026 ± 0.497 D in group 2, and - 0.130 ± 0.477 D in group 3. There was a significant difference between groups 1 and 2. There was no significant difference in the magnitude of preoperative corneal astigmatism and postoperative SE prediction error between the anterior corneal astigmatism orientation groups in eyes with axial lengths of less than or equal to 22.0 mm and greater than or equal to 25.0 mm. The orientation of preoperative anterior corneal astigmatism significantly affected the postoperative biometry prediction error in eyes with astigmatism of 1.75 D or less in eyes with the axial length between 22.0 mm and 25.0 mm. However, the results were not clinically significant.

  19. Posterior chamber phakic intraocular lens sizing based on iris pigment layer measurements by anterior segment optical coherence tomography.

    PubMed

    Malyugin, Boris E; Shpak, Alexander A; Pokrovskiy, Dmitry F

    2015-08-01

    To use anterior segment optical coherence tomography (AS-OCT) to evaluate the clinical effectiveness of Implantable Collamer Lens posterior chamber phakic intraocular lens (PC pIOL) sizing based on measurement of the distance from the iris pigment end to the iris pigment end. S. Fyodorov Eye Microsurgery Federal State Institution, Moscow, Russia. Evaluation of diagnostic test or technology. Stage 1 was a prospective study. The sulcus-to-sulcus (STS) distance was measured using ultrasound biomicroscopy (UBM) (Vumax 2), and the distance from iris pigment end to iris pigment end was assessed using a proposed AS-OCT algorithm. Part 2 used retrospective data from patients after implantation of a PC pIOL with the size selected according to AS-OCT (Visante) measurements of the distance from iris pigment end to iris pigment end. The PC pIOL vault was measured by AS-OCT, and adverse events were assessed. Stage 1 comprised 32 eyes of 32 myopic patients (mean age 28.4 years ± 6.3 [SD]; mean spherical equivalent [SE] -13.11 ± 4.28 diopters [D]). Stage 2 comprised 29 eyes of 16 patients (mean age 27.7 ± 4.7 years; mean SE -16.55 ± 3.65 D). The mean STS distance (12.35 ± 0.47 mm) was similar to the mean distance from iris pigment end to iris pigment end distance (examiner 1: 12.36 ± 0.51 mm; examiner 2: 12.37 ± 0.53 mm). The PC pIOL sized using the new AS-OCT algorithm had a mean vault of 0.53 ± 0.18 mm and did not produce adverse events during the 12-month follow-up. In 16 of 29 eyes, the PC pIOL vault was within an optimum interval (0.35 to 0.70 mm). The new measurement algorithm can be effectively used for PC pIOL sizing. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  20. MAHLI Calibration Target in Ultraviolet Light

    NASA Image and Video Library

    2012-02-07

    During pre-flight testing in March 2011, the Mars Hand Lens Imager MAHLI camera on NASA Mars rover Curiosity took this image of the MAHLI calibration target under illumination from MAHLI two ultraviolet LEDs light emitting diodes.

  1. Accommodation-Amplitudes following an Accommodative Lens Refilling Procedure — an in vivo Update

    PubMed Central

    Nishi, Okihiro; Nishi, Yutaro; Chang, S.; Nishi, Kayo

    2014-01-01

    Purpose To investigate whether a newly developed lens refilling procedure can provide some accommodation in monkey eyes and to evaluate the difference in accommodation with different degrees of capsular bag refilling. Setting Jinshikai Medical Foundation, Nishi Eye Hospital, Osaka, Japan. Design Experimental monkey study. Methods Following a central 3–4 mm continuous curvilinear capsulorhexis, phacoemulsification was performed in the usual manner. A novel accommodative membrane intraocular lens for sealing capsular opening was implanted into the capsular bag. Silicone polymers were injected beneath the intraocular lens into the capsular bag through the delivery hole. In three study groups, each with six monkey eyes, the lens capsule was refilled with 0.08 ml corresponding to 65% bag volume, 0.1 ml corresponding to 80% bag volume, and 0.125 ml of silicone polymers corresponding to 100% bag volume, respectively. To calculate the accommodation-amplitudes achieved, automated refractometry was performed before and 1 hour after the topical 4% pilocarpine application before and four weeks after surgery. Results The refilling technique was successful in all monkeys without polymer leakage. Accommodation-amplitudes attained were 2.56 ± 0.74 dioptries (D), 2.42 ± 1.00D, and 2.71 ± 0.63D, respectively, 4 weeks after surgery in the three study groups. Conclusions Using the technique, some accommodation could be obtained in the young monkey eyes. Leakage of the injectable silicone polymer and anterior capsular opacification at least in the visual axis could be avoided. The results suggest that this lens refilling procedure warrants further studies for a possible clinical application. PMID:24461501

  2. Visual Outcomes, Patient Satisfaction and Spectacle Independence with a Trifocal Diffractive Intraocular Lens.

    PubMed

    Kretz, Florian Tobias Alwin; Choi, Chul Young; Müller, Matthias; Gerl, Matthias; Gerl, Ralf Helmar; Auffarth, Gerd Uwe

    2016-06-01

    To evaluate visual outcomes following implantation of a trifocal diffractive intraocular lens (IOL) and to analyze their correlation with patient satisfaction and ease of performing daily tasks. This was a prospective study enrolling 100 eyes of 50 patients undergoing cataract surgery with implantation of trifocal IOL AT LISA tri 839MP. Visual and refractive outcomes were evaluated during a 3-month follow-up. Postoperatively, a questionnaire was used to evaluate patient satisfaction with regard to surgical outcome, spectacle independence, perception of photic phenomena, and ease of performing some vision-related activities. A total of 91%, 87%, and 79% of eyes achieved a monocular uncorrected distance, near, and intermediate visual acuity of 0.1 logarithm of the minimum angle of resolution or better, respectively. After the surgery, 96% of the patients could perform their daily activities without problems. The mean spectacle independence scores for reading, doing computer work, and for distance were 10.33 ± 12.47, 5.71 ± 11.90, and 3.92 ± 9.77, respectively (scale: 0 = no spectacles needed; 40 = spectacles always needed). No correlation was found between spectacle independence and visual outcome (-0.101 ≤ r ≤ 0.244, p ≥ 0.087). Mean scores (0 = no symptoms; 40 = strong symptoms) for glare at night, ghost images, and halos were 15.15 ± 12.02, 4.49 ± 7.92, and 13.34 ± 10.82, respectively. No correlation was found between photic phenomena and visual outcome (-0.199 ≤ r ≤ 0.209, p ≥ 0.150). A total of 80% of patients reported satisfaction with the surgery outcome, and 86% would recommend the surgery to friends and family. Implantation of the AT LISA tri 839MP IOL after cataract surgery provides effective visual restoration associated with a minimal level of photic phenomena, a positive impact on the performance of vision-related daily activities, and a high level of postoperative patient satisfaction.

  3. Visual Outcomes, Patient Satisfaction and Spectacle Independence with a Trifocal Diffractive Intraocular Lens

    PubMed Central

    Kretz, Florian Tobias Alwin; Choi, Chul Young; Müller, Matthias; Gerl, Matthias; Gerl, Ralf Helmar

    2016-01-01

    Purpose To evaluate visual outcomes following implantation of a trifocal diffractive intraocular lens (IOL) and to analyze their correlation with patient satisfaction and ease of performing daily tasks. Methods This was a prospective study enrolling 100 eyes of 50 patients undergoing cataract surgery with implantation of trifocal IOL AT LISA tri 839MP. Visual and refractive outcomes were evaluated during a 3-month follow-up. Postoperatively, a questionnaire was used to evaluate patient satisfaction with regard to surgical outcome, spectacle independence, perception of photic phenomena, and ease of performing some vision-related activities. Results A total of 91%, 87%, and 79% of eyes achieved a monocular uncorrected distance, near, and intermediate visual acuity of 0.1 logarithm of the minimum angle of resolution or better, respectively. After the surgery, 96% of the patients could perform their daily activities without problems. The mean spectacle independence scores for reading, doing computer work, and for distance were 10.33 ± 12.47, 5.71 ± 11.90, and 3.92 ± 9.77, respectively (scale: 0 = no spectacles needed; 40 = spectacles always needed). No correlation was found between spectacle independence and visual outcome (-0.101 ≤ r ≤ 0.244, p ≥ 0.087). Mean scores (0 = no symptoms; 40 = strong symptoms) for glare at night, ghost images, and halos were 15.15 ± 12.02, 4.49 ± 7.92, and 13.34 ± 10.82, respectively. No correlation was found between photic phenomena and visual outcome (-0.199 ≤ r ≤ 0.209, p ≥ 0.150). A total of 80% of patients reported satisfaction with the surgery outcome, and 86% would recommend the surgery to friends and family. Conclusions Implantation of the AT LISA tri 839MP IOL after cataract surgery provides effective visual restoration associated with a minimal level of photic phenomena, a positive impact on the performance of vision-related daily activities, and a high level of postoperative patient satisfaction. PMID:27247517

  4. Phakic Intraocular Lenses

    MedlinePlus

    ... Implants and Prosthetics Phakic Intraocular Lenses Phakic Intraocular Lenses Share Tweet Linkedin Pin it More sharing options Linkedin Pin it Email Print Phakic intraocular lenses are new devices used to correct nearsightedness. These ...

  5. Intraocular pressure, ultrasonographic and echobiometric findings of juvenile Yacare caiman (Caiman yacare) eye.

    PubMed

    Ruiz, Thaís; Campos, Wilma N S; Peres, Thalita P S; Gonçalves, Gentil F; Ferraz, Rosa H S; Néspoli, Pedro E B; Sousa, Valéria R F; Ribeiro, Alexandre P

    2015-01-01

    The aim was to determine the intraocular pressure (IOP), the ultrasonographic and echobiometric findings in the eyes of juvenile Yacare caiman (Caiman yacare). Twenty-two healthy caimans from a breeding farm in Brazilian Pantanal. Intraocular pressure was measured under physical restraint and topical anesthesia by applanation tonometry. Five individual measurements of each eye were recorded by the same examiner. B-mode ultrasonography was performed with a 10-MHz linear transducer, and the anterior chamber depth, lens thickness, vitreous depth, and axial globe length were measured. Unpaired and paired t-tests were used to assess data. Pearson's test was used to assess correlations between IOP and ocular structures (P < 0.05). Mean ± SD IOP of the 44 eyes studied was 9.56 ± 2.69 mmHg, (range 5.4-15.6 mmHg). IOP did not differ significantly between right and left eyes or between genders (P > 0.05). Echobiometric measurements did not differ significantly between eyes and genders (P > 0.05). Intraocular structures measured in male and female subjects were, respectively, 2.61 ± 0.13 and 2.55 ± 0.18 mm for anterior chamber depth, 7.60 ± 0.17 and 7.54 ± 0.20 mm for lens thickness, 6.83 ± 0.20 and 6.90 ± 0.22 mm for vitreous chamber depth, and 17.55 ± 0.25 and 17.54 ± 0.29 mm for axial globe length. Correlations were not observed (P > 0.05). Reference values of tonometry and distances of intraocular structures of Yacare caiman were described. IOP did not correlate with echobiometric measurements in this crocodilian. The ultrasonographic appearance was similar to other domestic and wild species. © 2014 American College of Veterinary Ophthalmologists.

  6. Attenuating Photostress and Glare Disability in Pseudophakic Patients through the Addition of a Short-Wave Absorbing Filter.

    PubMed

    Hammond, Billy R

    2015-01-01

    To evaluate the effects of filtering short wavelength light on visual performance under intense light conditions among pseudophakic patients previously implanted with a clear intraocular lens (IOL). This was a patient-masked, randomized crossover study conducted at 6 clinical sites in the United States between September 2013 and January 2014. One hundred fifty-four bilaterally pseudophakic patients were recruited. Photostress recovery time and glare disability thresholds were measured with clip-on blue-light-filtering and placebo (clear; no blue-light filtration) glasses worn over patients' habitual correction. Photostress recovery time was quantified as the time necessary to regain sight of a grating target after intense light exposure. Glare disability threshold was assessed as the intensity of a white-light annulus necessary to obscure a central target. The order of filter used and test eye were randomized across patients. Photostress recovery time and glare disability thresholds were significantly improved (both P < 0.0001) when patients used blue-light-filtering glasses compared with clear, nonfiltering glasses. Compared with a nonfiltering placebo, adding a clip-on blue-absorbing filter to the glasses of pseudophakic patients implanted with clear IOLs significantly increased their ability to cope with glare and to recover normal viewing after an intensive photostress. This result implies that IOL designs with blue-light-filtering characteristics may be beneficial under intense light conditions.

  7. Evaluation of the True Wavefront Aberrations in Eyes Implanted With a Rotationally Asymmetric Multifocal Intraocular Lens.

    PubMed

    Akondi, Vyas; Pérez-Merino, Pablo; Martinez-Enriquez, Eduardo; Dorronsoro, Carlos; Alejandre, Nicolás; Jiménez-Alfaro, Ignacio; Marcos, Susana

    2017-04-01

    Standard evaluation of aberrations from wavefront slope measurements in patients implanted with a rotationally asymmetric multifocal intraocular lens (IOL), the Lentis Mplus (Oculentis GmbH, Berlin, Germany), results in large magnitude primary vertical coma, which is attributed to the intrinsic IOL design. The new proposed method analyzes aberrometry data, allowing disentangling the IOL power pupillary distribution from the true higher order aberrations of the eye. The new method of wavefront reconstruction uses retinal spots obtained at both the near and far foci. The method was tested using ray tracing optical simulations in a computer eye model virtually implanted with the Lentis Mplus IOL, with a generic cornea or with anterior segment geometry obtained from custom quantitative spectral-domain optical coherence tomography in a real patient. The method was applied to laser ray tracing aberrometry data at near and far fixation obtained in a patient implanted with the Lentis Mplus IOL. Higher order aberrations evaluated from simulated and real retinal spot diagrams following the new reconstruction approach matched the nominal aberrations (approximately 98%). Previously reported primary vertical coma in patients implanted with this IOL lost significance with the application of the proposed reconstruction. Custom analysis of ray tracing-based retinal spot diagrams allowed decoupling of the true higher order aberrations of the patient's eye from the power pupillary distribution of a rotationally asymmetric multifocal IOL, therefore providing the appropriate phase map to accurately evaluate through-focus optical quality. [J Refract Surg. 2017;33(4):257-265.]. Copyright 2017, SLACK Incorporated.

  8. Capture of intraocular lens optic by residual capsular opening in secondary implantation: long-term follow-up.

    PubMed

    Tian, Tian; Chen, Chunli; Jin, Haiying; Jiao, Lyu; Zhang, Qi; Zhao, Peiquan

    2018-04-02

    To introduce a novel surgical technique for optic capture by residual capsular opening in secondary intraocular lens (IOL) implantation and to report the outcomes of a long follow-up. Twenty patients (20 eyes) who had received secondary IOL implantation with the optic capture technique were retrospectively reviewed. We used the residual capsular opening for capturing the optic and inserted the haptics in the sulcus during surgery. Baseline clinical characteristics and surgical outcomes, including best-corrected visual acuity (BCVA), refractive status, and IOL position were recorded. The postoperative location and stability of IOL were evaluated using the ultrasound biomicroscopy. Optic capture technique was successfully performed in all cases, including 5 cases with large area of posterior capsular opacity, 6 cases with posterior capsular tear or rupture,and 9 cases with adhesive capsules. BCVA improved from 0.60 logMAR at baseline to 0.36 logMAR at the last follow-up (P < 0.001). Spherical equivalent changed from 10.67 ± 4.59 D at baseline to 0.12 ± 1.35 D at 6 months postoperatively (P < 0.001). Centered IOLs were observed in all cases and remained captured through residual capsular opening in 19 (95%) eyes at the last follow-up. In one case, the captured optic of IOL slid into ciliary sulcus at 7 months postoperatively. No other postoperative complications were observed in any cases. This optic capture technique by using residual capsule opening is an efficacious and safe technique and can achieve IOL stability in the long follow-up.

  9. Comparison of two different methods of preoperative marking for toric intraocular lens implantation: bubble marker versus pendulum marker.

    PubMed

    Farooqui, Javed Hussain; Koul, Archana; Dutta, Ranjan; Shroff, Noshir Minoo

    2016-01-01

    To compare the accuracy of two different methods of preoperative marking for toric intraocular lens (IOL) implantation, bubble marker versus pendulum marker, as a means of establishing the reference point for the final alignment of the toric IOL to achieve an outcome as close as possible to emmetropia. Toric IOLs were implanted in 180 eyes of 110 patients. One group (55 patients) had preoperative marking of both eyes done with bubble marker (ASICO AE-2791TBL) and the other group (55 patients) with pendulum marker (Rumex(®)3-193). Reference marks were placed at 3-, 6-, and 9-o'clock positions on the limbus. Slit-lamp photographs were analyzed using Adobe Photoshop (version 7.0). Amount of alignment error (in degrees) induced in each group was measured. Mean absolute rotation error in the preoperative marking in the horizontal axis was 2.42±1.71 in the bubble marker group and 2.83±2.31in the pendulum marker group (P=0.501). Sixty percent of the pendulum group and 70% of the bubble group had rotation error ≤3 (P=0.589), and 90% eyes of the pendulum group and 96.7% of the bubble group had rotation error ≤5 (P=0.612). Both preoperative marking techniques result in approximately 3 of alignment error. Both marking techniques are simple, predictable, reproducible and easy to perform.

  10. Clinical magnification and residual refraction after implantation of a double intraocular lens system in patients with macular degeneration.

    PubMed

    Amselem, Luis; Diaz-Llopis, Manuel; Felipe, Adelina; Artigas, Jose M; Navea, Amparo; García-Delpech, Salvador

    2008-09-01

    To evaluate the efficacy of a standard double intraocular lens (IOL) system (IOL-Vip) in patients with low vision and central scotoma due to macular degeneration and assess the predictability of the residual refraction and magnification. Ophthalmology Department, Hospital General Universitario, Valencia, Spain. This interventional prospective noncomparative case series comprised 13 consecutive surgical procedures in 10 patients with central scotoma. Follow-up was 12 months. Evaluation included the difference between preoperative and postoperative best corrected visual acuity (BCVA), refraction, position of the IOLs, endothelial cell density, and occurrence of postoperative complications. Residual refraction and eye magnification were calculated using a theory developed in a previous study, and the values were compared with the clinical results. The mean BCVA was 1.37 logMAR preoperatively and 0.68 logMAR 1 year postoperatively. The mean best corrected clinical gain was 44%. There was no statistically significant difference between the clinically evaluated and theoretically calculated residual refractions (P = .17). No intraoperative or postoperative complications occurred. Implantation of the double IOL system improved BCVA in patients with low vision due to advanced maculopathy. The results were best in myopic patients (long eyes); patients with hyperopia (short eyes) had high residual refraction. The postoperative clinical gain and residual refraction were predictable, showing the feasibility of implanting a customized double IOL.

  11. Reduction in mean deviation values in automated perimetry in eyes with multifocal compared to monofocal intraocular lens implants.

    PubMed

    Farid, Marjan; Chak, Garrick; Garg, Sumit; Steinert, Roger F

    2014-08-01

    To evaluate differences in mean deviation values in automated perimetry in healthy eyes with multifocal compared to monofocal intraocular lens (IOL) implants. Prospective, age-matched, comparative analysis. Single-center, tertiary referral academic practice. A total of 37 healthy eyes in 37 patients with bilateral multifocal (n=22) or monofocal (n=15) IOL implants were studied. INTERVENTION/OBSERVATION PROCEDURE: Humphrey Visual Field 10-2 testing was performed on all patients. Mean deviation (MD) and pattern standard deviation (PSD) numerical values were evaluated and compared between groups. The average MD was -2.84 dB (SD 2.32) for the multifocal IOL group and -0.97 dB (SD 1.58) for the monofocal IOL group (P=.006). There was no significant difference in PSD between the 2 groups (P=.99). Eyes that had the visual field 10-2 testing≥6 months from time of IOL placement showed no improvement in MD when compared to eyes that were tested within 6 months from IOL placement. Multifocal IOL implants cause significant nonspecific reduction in MD values on Humphrey Visual Field 10-2 testing that does not improve with time or neuroadaptation. Multifocal IOL implants may be inadvisable in patients where central visual field reduction may not be tolerated, such as macular degeneration, retinal pigment epithelium changes, and glaucoma. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. UV-B-induced damage to the lens in vitro: prevention by caffeine.

    PubMed

    Varma, Shambhu D; Hegde, Kavita R; Kovtun, Svitlana

    2008-10-01

    Ultraviolet (UV) irradiation is one of the significant risk factors in the genesis of cataracts. Pathogenetically, the process can be triggered by the intraocular generation of various reactive species of oxygen that are well known to be initiated by the penetration of light, especially of the UV frequencies. The contribution of UV exposure in the etiology of this disease is likely to increase further due to ozone depletion in the upper atmosphere. The present studies were undertaken to examine if the UV effects can be attenuated with the xanthine-based alkaloids primarily present in tea and coffee. We have examined this possibility by in vitro lens culture studies with caffeine. As expected, mice lenses incubated in Tyrode solution exposed to UV at 302 nm are physiologically damaged, as evidenced by the inhibition of the active transport of (86)Rb(+), an ion acting as a surrogate of the K(+). There was a simultaneous decrease in the levels of adenosine triphosphate and glutathione. The addition of caffeine to the medium prevented such deleterious effects. That caffeine and perhaps other xanthinoids have a protective effect against cataract formation induced by UV has hence been demonstrated for the first time.

  13. Prevention of suture knot exposure in posterior chamber intraocular lens implantation by 4-point scleral fixation technique.

    PubMed

    Baykara, Mehmet; Avci, Remzi

    2004-01-01

    The results and complications of posterior chamber intraocular lens (IOL) implantation by a 4-point scleral fixation technique are described. Fifty eyes of 47 patients who underwent scleral-fixated IOL implantation were retrospectively evaluated. Twenty-one (42%) eyes had a history of trauma and 29 (58%) eyes had previously undergone cataract surgery. In all cases, IOL implantation by 4-point scleral fixation was performed and the knots of fixation sutures were rotated and buried in the globe. The IOL position was adjusted by suture rotation for best centration. The mean follow-up time was 7 +/- 4 months. Four (8%) eyes had minimal corneal edema preoperatively. Cystoid macular edema was noted in 2 (6.8%) eyes in the cataract surgery group and 8 (38%) eyes in the posttraumatic group. Two (9.5%) eyes in the posttraumatic group had atrophic macular changes and 1 (4.7%) had corneal scarring, which impaired vision. No complications such as knot exposure, tilting of the IOL, decentralization, or endophthalmitis were noted postoperatively. Postoperative mean corrected visual acuity was 0.4 +/- 0.3 in the posttraumatic group and 0.4 +/- 0.2 in the cataract surgery group. The 4-point scleral fixation technique resulted in no serious postoperative complications such as suture exposure and endophthalmitis. Because the knot can be rotated and buried in the globe, knot exposure is less likely to occur. This procedure is more effective than other techniques regarding IOL centralization.

  14. Central Corneal Thickness and its Relationship to Intra-Ocular and Epidmiological Determinants.

    PubMed

    Tayyab, Ali; Masrur, Amena; Afzal, Farooq; Iqbal, Fyza; Naseem, Kamran

    2016-06-01

    To measure central corneal thickness in Pakistani population and determine its relationship to intra-ocular pressure, age, gender and ethnicity. Cross-sectional observation study. Pakistan Institute of Medical Sciences, Islamabad, Pakistan, between December 2013 and February 2015. The right eyes of 1000 cases (496 males and 504 females) were recruited for this study. Inclusion criteria were Pashtun or Punjabi ethnicity, intra-ocular pressure < 22 mmHg, gonioscopically open angles, cup-disk-ratio < 0.5, and age matched normal visual fields. Cases with prior ocular surgery, contact lens use, corneal pathologies, myopia or hypermetropia > ±3.0 diopters, astigmatism of > ±1.0 diopters were excluded. Central corneal thickness was measured using a TopCon non-contact specular microscope. Intra-ocular pressure was measured using Goldmann applanation tonometer. Frequency distribution, test of significance, and regression analysis was carried out using Statistical Package for Social Sciences version 20.0. Mean age was 47.31 ±11.78 years. Ethnic composition was 51.6% (n=516) Pashtun and 48.4% (n=484) Punjabi. The mean central corneal thickness was 503.96 (±12.47) µm, while the mean intra-ocular pressure was 15.61 (±2.68) mmHg. Regression analysis showed a significant association between central corneal thickness and intra-ocular pressure (p=0.00) and age (p=0.00). A±100 µchange in central corneal thickness was associated with change in IOPof ±3.30 mmHg, whereas central corneal thickness decreased by 0.12 µm per year. No significant association could be established between central corneal thickness and ethnicity (p=0.19). Central corneal thickness of the studied races was comparable to non-Caucasians which affects intra-ocular pressure measurements, and decreases with increasing age. No relationship was observed between central corneal thickness and ethnicity or gender.

  15. Phakic Intraocular Collamer Lens (Visian ICL) Implantation for Correction of Myopia in Spectacle-Aversive Special Needs Children.

    PubMed

    Tychsen, Lawrence; Faron, Nicholas; Hoekel, James

    2017-03-01

    A subset of children with high anisometropia or isoametropia and neurobehavioral disorders have chronic difficulties with spectacle or contact lens wear. We report the results of refractive surgery in a series of these children treated using bilateral or unilateral intraocular collamer lens (Visian ICL) implantation for moderate to high myopia. Prospective nonrandomized cohort study. Clinical course and outcome data were collated prospectively for 40 implanted eyes in 23 children (mean age 10.2 ± 5.3 years, range, 1.8-17 years). Myopia ranged from -3.0 to -14.5 diopters (D), mean -9.2 ± 3.5 D. Goal refraction was plano to +1 D. Correction was achieved by sulcus implantation of a Visian ICL (STAAR Surgical, Monrovia, California, USA) under general anesthesia. Mean follow-up was 15.1 months (range, 6-22 months). Thirty-five eyes (88%) were corrected to within ±1.0 D of goal refraction; the other 5 (12%) were corrected to within 1.5 D. Uncorrected distance visual acuity improved substantially in all eyes (from mean 20/1050 [logMAR 1.72] to mean 20/42 [logMAR 0.48]). Spherical regression at last follow-up was an average of +0.59 D. Visuomotor comorbidities (eg, amblyopia, nystagmus, foveopathy, optic neuropathy) accounted for residual postoperative subnormal visual acuity. Thirteen of the 23 children (57%) had a neurobehavioral disorder (eg, developmental delay/intellectual disability/mental retardation, Down syndrome, cerebral palsy, autism spectrum disorder). Eighty-five percent (11/13) of those children were reported to have enhanced visual awareness, attentiveness, or social interactions. Endothelial cell density was measureable in 6 cooperative children (10 eyes), showing an average 1% decline. Central corneal thickness, measured in all children, increased an average of 8 μm. Two children (8%) required unplanned return to the operating room on the first postoperative day to alleviate pupillary block caused by a nonpatent iridotomy. No other

  16. Evolution of light scattering and redox balance in the rat lens after in vivo exposure to close-to-threshold dose ultraviolet radiation.

    PubMed

    Wang, Jing; Löfgren, Stefan; Dong, Xiuqin; Galichanin, Konstantin; Söderberg, Per G

    2010-11-01

    To investigate the evolution of cataract development and glutathione redox balance in the rat lens after in vivo close-to-threshold dose exposure to ultraviolet radiation (UVR) around 300 nm. Three groups of 10 Sprague-Dawley rats were unilaterally exposed to 8 kJ/m² UVR-300 nm for 15 min, and a fourth group of 10 rats was kept without UVR exposure as nonexposed control animals. The exposed animals were killed at 1, 3 and 7 days after exposure. Both lenses from all animals were extracted and photographed and the intensity of forward light scattering was measured quantitatively. Thereafter, the lenses were homogenized. The concentration of reduced glutathione (GSH) and oxidized glutathione (GSSG), and the activity of glutathione reductase (GR) and glutathione peroxidase (GPx), respectively, were determined spectrophotometrically. The mean paired differences between exposed and nonexposed lenses were used as primary data in the statistical analyses. All exposed lenses developed cataract. Lens light scattering increased throughout the 7 days after UVR exposure. GSH concentration and GPx rate transiently increased at 1 day after exposure and then decreased throughout follow-up, with GSH concentration having a negative balance at the end. GSSG concentration and GR activity did not change after UVR exposure. In vivo close-to-threshold UVR exposure induces a gradual increase in rat lens opacification/cataract development and time dependently alters the redox balance in the lens. © 2010 The Authors. Journal compilation © 2010 Acta Ophthalmol.

  17. Capsule-Fixated Intraocular Lens Implantation in Small Pupil Cases.

    PubMed

    Schojai, Merita; Schultz, Tim; Burkhard Dick, H

    2017-08-01

    To describe a new technique for implantation of capsule-fixated intraocular lenses (IOLs) (FEMTIS; Oculentis, Berlin, Germany) in patients with small pupils. In 4 eyes with small pupils, an anterior capsule-fixated IOL was implanted into the capsular bag after femtosecond laser treatment. The two large and two small flaps of the IOL were elevated to the front of the iris and the anterior capsule. Finally, the iris was flipped over the flaps to ensure a fixation of the capsule inside of the capsulotomy. In all cases, the implantation of anterior capsule-fixated IOLs was possible. No complications occurred during surgery or within the first months after surgery. With the described technique, capsulefixated IOLs can be implanted in eyes with small pupil easily and safely. This type of IOL has great potential to improve the refractive outcome by better prediction of the postoperative IOL position and eliminating IOL rotation after cataract surgery. [J Refract Surg. 2017;33(8):568-570.]. Copyright 2017, SLACK Incorporated.

  18. Scanning electron microscopic and histologic evaluation of the AcrySof SA30AL acrylic intraocular lens. Manufacturing quality and morphology in the capsular bag.

    PubMed

    Escobar-Gomez, Marcela; Apple, David J; Vargas, Luis G; Werner, Liliana; Arthur, Stella N; Pandey, Suresh K; Izak, Andrea M; Schmidbauer, Josef M

    2003-01-01

    To evaluate the properties of the AcrySof(R) SA30AL (Alcon Laboratories, Inc.) single-piece foldable posterior chamber intraocular lens (IOL). Center for Research on Ocular Therapeutics and Biodevices, Storm Eye Institute, Medical University of South Carolina, Charleston, South Carolina, USA. Two nonimplanted clinical-quality AcrySof IOLs were examined by gross, light, and scanning electron microscopy (SEM). In addition, 2 eyes implanted with this IOL obtained post-mortem, the first such eyes accessioned in our laboratory and the first described to date, were examined using the Miyake-Apple posterior photographic technique and by histologic sections. Scanning electron microscopy of the SA30AL IOL showed excellent surface finish. The edge of the optic was square (truncated) and had a matte (velvet or ground-glass) appearance, a feature that may minimize edge glare and other visual phenomena. A well-fabricated square or truncated optic edge was demonstrated. Miyake-Apple analysis revealed that the SA30AL IOL showed appropriate fit and configuration within the capsular bag. Histologic correlation of the IOL's square edge and its relation to the capsular bag and adjacent Soemmering's ring were noted. The AcrySof SA30AL IOL is a well-fabricated lens that situates well in the capsular bag. The truncated optic and its relationship to adjacent structures show a morphological profile that has been shown to be highly efficacious in reducing the rate of posterior capsule opacification.

  19. [Implantation of intraocular lenses in the ciliary sulcus].

    PubMed

    Schulze, S; Bertelmann, T; Sekundo, W

    2014-04-01

    Implantation of an intraocular lens (IOL) into the ciliary sulcus is the second most common implantation site after the regular capsular bag (in the bag) placement of an IOL. Although mainly not primarily intended, it is very often used in both complicated cataract surgery and secondary implantation due to IOL dislocation or aphakia. In most cases stable positioning is possible, especially when using optic capture techniques. A variety of difficulties can occur with sulcus implantation depending on the anatomical and surgical conditions present at the time of implantation. The most anterior position of the sulcus lense has to be considered for calculation of the refractive power of the IOL.

  20. Comparison of clinical outcomes of iris fixation and scleral fixation as treatment for intraocular lens dislocation.

    PubMed

    Kim, Kyeong Hwan; Kim, Wan Soo

    2015-09-01

    To compare the efficacy and safety of iris fixation with scleral fixation in surgical repositioning of dislocated intraocular lenses (IOLs). Retrospective, consecutive, comparative interventional case series. setting: Referral hospital. Seventy-eight consecutive patients who underwent surgical repositioning of dislocated intraocular lenses using suturing to the sclera or iris. Forty-four eyes of 44 patients underwent scleral fixation and 35 eyes of 34 patients underwent iris fixation of dislocated intraocular lenses. Visual acuity, refractive stability, operation time, and perioperative complications, including recurrence of IOL dislocation. Corrected distance visual acuity (CDVA) improved significantly 1 month postoperatively in both groups (P < .01 each), and remained stable for 12 months. One week postoperatively, however, CDVA improved significantly in the scleral fixation (P = .040) but not in the iris fixation (P = .058) group. The amount of refractive error significantly diminished 1 day after surgery (P = .028 in the scleral fixation and P = .046 in the iris fixation group). For the astigmatic components, Jackson crossed cylinders equivalent to conventional cylinders of positive power at axes of 0 degrees (J0) and 45 degrees (J45), J45 differed significantly in the scleral fixation and iris fixation groups (P = .009), whereas J0 was similar (P > .05). Operation time was significantly shorter (P = .0007), while immediate postoperative inflammation was significantly more severe (P = .001), in the iris fixation than in the scleral fixation group. Recurrence rates were similar (P > .05), but the mean time to recurrence was significantly shorter in the iris fixation than in the scleral fixation group (P = .031). Iris fixation and scleral fixation techniques had similar efficacy in the repositioning of dislocated intraocular lenses. Although operation time was shorter for iris fixation, it had several disadvantages, including induced astigmatism

  1. Ultraviolet spectrophotometer for measuring columnar atmospheric ozone from aircraft

    NASA Technical Reports Server (NTRS)

    Hanser, F. A.; Sellers, B.; Briehl, D. C.

    1978-01-01

    An ultraviolet spectrophotometer (UVS) to measure downward solar fluxes from an aircraft or other high altitude platform is described. The UVS uses an ultraviolet diffuser to obtain large angular response with no aiming requirement, a twelve-position filter wheel with narrow (2-nm) and broad (20-nm) bandpass filters, and an ultraviolet photodiode. The columnar atmospheric ozone above the UVS (aircraft) is calculated from the ratios of the measured ultraviolet fluxes. Comparison with some Dobson station measurements gives agreement to 2%. Some UVS measured ozone profiles over the Pacific Ocean for November 1976 are shown to illustrate the instrument's performance.

  2. An RFID-based on-lens sensor system for long-term IOP monitoring.

    PubMed

    Hsu, Shun-Hsi; Chiou, Jin-Chern; Liao, Yu-Te; Yang, Tzu-Sen; Kuei, Cheng-Kai; Wu, Tsung-Wei; Huang, Yu-Chieh

    2015-01-01

    In this paper, an RFID-based on-lens sensor system is proposed for noninvasive long-term intraocular pressure monitoring. The proposed sensor IC, fabricated in a 0.18um CMOS process, consists of capacitive sensor readout circuitry, RFID communication circuits, and digital processing units. The sensor IC is integrated with electroplating capacitive sensors and a receiving antenna on the contact lens. The sensor IC can be wirelessly powered, communicate with RFID compatible equipment, and perform IOP measurement using on-lens capacitive sensor continuously from a 2cm distance while the incident power from an RFID reader is 20 dBm. The proposed system is compatible to Gen2 RFID protocol, extending the flexibility and reducing the self-developed firmware efforts.

  3. Synthetic ultraviolet light filtering chemical contamination of coastal waters of Virgin Islands National Park, St. John, U.S. Virgin Islands

    USGS Publications Warehouse

    Bargar, Timothy A.; Alvarez, David; Garrison, Virginia H.

    2015-01-01

    Contamination of surface waters by synthetic ultraviolet light (UV) filtering chemicals is a concern for the Virgin Islands National Park (VINP). Discrete water samples were collected from VINP bays to determine UV filter chemical presence in the coastal waters. Spatial distribution and the potential for partitioning between subsurface waters and the sea surface microlayer (SML) were also examined. The UV filter chemicals 4-methylbenzylidene camphor, benzophenone-3, octinoxate, homosalate, and octocrylene were detected at concentrations up to 6073 ng/L (benzophenone-3). Concentrations for benzophenone-3 and homosalate declined exponentially (r2 = 0.86 to 0.98) with distance from the beach. Limited data indicate that some UV filter chemicals may partition to the SML relative to the subsurface waters. Contamination of VINP coastal waters by UV filter chemicals may be a significant issue, but an improved understanding of the temporal and spatial variability of their concentrations would be necessary to better understand the risk they present.

  4. Clinical outcomes and surgeon assessment after implantation of a new diffractive multifocal toric intraocular lens.

    PubMed

    Kretz, Florian T A; Bastelica, Antoine; Carreras, Humberto; Ferreira, Tiago; Müller, Matthias; Gerl, Matthias; Gerl, Ralf; Saeed, Manzar; Schmickler, Stefanie; Auffarth, Gerd U

    2015-03-01

    To evaluate the clinical outcome in eyes with significant corneal astigmatism after cataract surgery with implantation of a new diffractive multifocal toric intraocular lens (IOL). Prospective, non-randomised multicentre clinical study including 57 eyes of 38 consecutive patients with an age between 37 and 84 years that underwent cataract surgery with implantation of the toric multifocal IOL Tecnis ZMT (Abbott Medical Optics, Santa Ana, California, USA). Changes in uncorrected and corrected logMAR distance, intermediate and near visual acuity ((uncorrected distance visual acuity (UDVA), uncorrected intermediate visual acuity (UIVA) uncorrected near visual acuity (UNVA), corrected distance visual acuity (CDVA), corrected near visual acuity) and manifest refraction were evaluated during a 2-4 month follow-up. Additionally, patients were asked about photic phenomena and spectacle dependence. The surgeons subjectively assessed various aspects of the surgery. A significant improvement in CDVA was observed postoperatively (p<0.01), with a significant reduction in manifest cylinder (p<0.01). Mean postoperative binocular UDVA and UNVA were 0.04±0.10 and 0.06±0.12, respectively. Monocular UDVA and UNVA was 0.20 or better in 85.4% and 87.0% of eyes, respectively. Mean binocular logMAR UIVA was 0.21±0.20. Only 10.5% of patients required postoperative correction for near or intermediate distance. The incidence of moderate to severe photic phenomena was limited. Surgeons defined the IOL implantation in most cases as easy or very easy, with a satisfaction rate with the procedure of 84%. The implantation of the multifocal toric IOL is a safe procedure that provides a very good visual rehabilitation in eyes with corneal astigmatism. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  5. Effect of supplementary implantation of a sulcus-fixated intraocular lens in patients with negative dysphotopsia.

    PubMed

    Makhotkina, Natalia Y; Dugrain, Vincent; Purchase, Daniel; Berendschot, Tos T J M; Nuijts, Rudy M M A

    2018-02-01

    To evaluate whether the outcome of negative dysphotopsia treatment by implantation of a Sulcoflex intraocular lens (IOL) can be understood using individual biometry and optical modeling data. University Eye Clinic, Maastricht University Medical Centre, Maastricht, the Netherlands. Retrospective case series. Patients with negative dysphotopsia were treated with supplementary implantation of a sulcus-fixated IOL. Preoperative and postoperative ray-tracing optical models of eyes with negative dysphotopsia were constructed in the Zemax Optic Studio program using individual biometric data. The relationship between biometric parameters, ray-tracing data, and the course of negative dysphotopsia was evaluated. The study comprised 8 patients (10 eyes). After surgery, negative dysphotopsia resolved completely in 6 eyes, partially in 2 eyes, and persisted in 2 eyes. There was no relationship between the course of negative dysphotopsia and age, IOL power, or individual biometry results other than a larger angle κ that was observed in 2 patients with persistent negative dysphotopsia after surgery. Preoperative ray-tracing models showed a decrease in light irradiance at the periphery relative to the center of visual field. After sulcus-fixated IOL implantation, this decrease partially resolved, in particular, for a small pupil aperture (P < .05), and it was more prominent in patients in whom negative dysphotopsia resolved completely than in those with partial or persistent negative dysphotopsia (P = .065 at 1.5 mm aperture). Of all individual biometry results, only angle κ showed a relationship with the course of negative dysphotopsia. In patient-specific optical modeling of sulcus-fixated IOL implantation, the increase in simulated light irradiance at the periphery was related to the course of negative dysphotopsia. Copyright © 2018 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  6. Design, fabrication, and characterization of Fresnel lens array with spatial filtering for passive infrared motion sensors

    NASA Astrophysics Data System (ADS)

    Cirino, Giuseppe A.; Barcellos, Robson; Morato, Spero P.; Bereczki, Allan; Neto, Luiz G.

    2006-09-01

    A cubic-phase distribution is applied in the design, fabrication and characterization of inexpensive Fresnel lens arrays for passive infrared motion sensors. The resulting lens array produces a point spread function (PSF) capable of distinguish the presence of humans from pets by the employment of the so-called wavefront coding method. The cubic phase distribution used in the design can also reduce the optical aberrations present in the system. This aberration control allows a high tolerance in the fabrication of the lenses and in the alignment errors of the sensor. In order to proof the principle, a lens was manufactured on amorphous hydrogenated carbon thin film, by well-known micro fabrication process steps. The optical results demonstrates that the optical power falling onto the detector surface is attenuated for targets that present a mass that is horizontally distributed in space (e.g. pets) while the optical power is enhanced for targets that present a mass vertically distributed in space (e.g. humans). Then a mould on steel was fabricated by laser engraving, allowing large-scale production of the lens array in polymeric material. A polymeric lens was injected and its optical transmittance was characterized by Fourier Transform Infrared Spectrometry technique, which has shown an adequate optical transmittance in the 8-14 μm wavelength range. Finally the performance of the sensor was measured in a climate-controlled test laboratory constructed for this purpose. The results show that the sensor operates normally with a human target, with a 12 meter detection zone and within an angle of 100 degrees. On the other hand, when a small pet runs through a total of 22 different trajectories no sensor trips are observed. The novelty of this work is the fact that the so-called pet immunity function was implemented in a purely optical filtering. As a result, this approach allows the reduction of some hardware parts as well as decreasing the software complexity, once the

  7. Comparison of glare in YAG-damaged intraocular lenses: injection-molded versus lathe-cut.

    PubMed

    Bath, P E; Dang, Y; Martin, W H

    1986-11-01

    A comparative analysis of YAG laser intraocular lens (IOL) damage was undertaken on injection-molded and lathe-cut IOLs. Damage sites were evaluated with polarized light. A consistent positive polarization was observed in the damage sites of lathe-cut IOLs. A consistent negative polarization was observed in the damage sites of injection-molded IOLs. The presence of positive polarization in IOL damage sites may be correlated with increased potential for glare. Results and clinical implications are discussed.

  8. Visual and Refractive Outcomes following Bilateral Implantation of Extended Range of Vision Intraocular Lens with Micromonovision

    PubMed Central

    Ganesh, Sri; Relekar, Kirti J.

    2018-01-01

    Purpose To evaluate the outcomes following bilateral ERV intraocular lens implantation with micromonovision. Methods 25 subjects underwent bilateral Tecnis Symfony IOL implantation with micromonovision. The dominant eye was targeted for emmetropia and the nondominant eye for myopia of −0.75 D. Uncorrected and corrected distance (UDVA, CDVA), intermediate (UIVA, CIVA), and near visual acuity (UNVA, DCNVA); reading performance; defocus curve; and contrast sensitivity were studied. Follow-ups were conducted at 1 week and 1 and 6 months postoperatively. Results At 6 months postoperatively, the mean binocular UDVA, CDVA, UNVA, and DCNVA were −0.036 ± 0.09, −0.108 ± 0.07, 0.152 ± 0.11, and 0.216 ± 0.10 logMAR, respectively. Binocular UIVA and DCIVA were 0.048 ± 0.09 and 0.104 ± 0.08 logMAR, respectively, at 60 cm and −0.044 ± 0.09 and 0.012 ± 0.09 logMAR, respectively, at 80 cm. All patients had ≥0.2 logMAR UDVA and UNVA. Reading acuity and reading speeds showed improvement over time. Between defocus range of −2.50 and +1.00 D, the visual acuity remained ≥0.2 logMAR. Contrast sensitivity scores were within the normal range. 4 patients used reading glasses for very fine print. Conclusion Bilateral ERV IOL implantation leads to excellent outcomes for far and intermediate vision, satisfactory outcomes for near vision, and good tolerance to micromonovision at the end of the 6 months. This trial is registered with CTRI/2015/10/006246. PMID:29545954

  9. Scleral fixation of one piece intraocular lens by injector implantation

    PubMed Central

    Can, Ertuğrul; Başaran, Reşat; Gül, Adem; Birinci, Hakkı

    2014-01-01

    Aim of Study: With an ab-interno technique of transscleral suturing of current one-piece posterior chamber intraocular lenses (PC IOLs) by injector implantation in the absence of capsular support, we aimed to demonstrate the possibility of the implantation of one-piece acrylic PC IOLs that might be produced in the future for only scleral fixation through small clear corneal incision. Materials and Methods: Case report and literature review. Results: This procedure has been performed in eight aphakic eyes with four different types of IOLs. Good centration was achieved with minimal technical effort. All patients had well-centered and stable lenses postoperatively during 9-18 months follow-up. Conclusion: We managed to decrease the risks of surgical trauma and intricate surgical maneuvers requirement. With this technique, excessive fluid leakage and consecutive hypotony can be minimized. PMID:25230961

  10. Simulation of air-bag impact on an eye with transsclerally fixated posterior chamber intraocular lens using finite element analysis.

    PubMed

    Uchio, Eiichi; Kadonosono, Kazuaki; Matsuoka, Yasuhiro; Goto, Satoru

    2004-02-01

    To determine the physical and mechanical conditions of an impacting air bag that would rupture an eye with a transsclerally fixated posterior chamber intraocular lens (IOL). Numerical simulation study on a computer. Simulations in a model human eye were performed with a computer using the finite element analysis program PAM-CRASH (Nihon ESI). The air bag was set to impact the surface of an eye with a transsclerally fixated posterior chamber IOL at various velocities. The tensile force limit of a 10-1 polypropylene suture was assumed to be 0.16 N, which is specified in the U.S. Pharmacopeia XXII. At the lowest velocity of 20.0 m/s, 10-0 polypropylene sutures were not likely to break. Sutures fixating the IOL might break and a corneoscleral incision was likely to open after 0.3 second at the medium impacting velocity (30 m/s). Suture rupture was very likely at the highest velocity (40 m/s) since the tensile force on the sutures continuously exceeded the breaking force after the impact. In an eye with a transsclerally fixated posterior chamber IOL, severe ocular trauma can be caused by an air bag at high velocity. Small individuals such as elderly women are at greater risk for air-bag ocular injury. Further research on modifying air-bag design and deployment is important to minimize the risk for ocular injury.

  11. High order aberration and straylight evaluation after cataract surgery with implantation of an aspheric, aberration correcting monofocal intraocular lens

    PubMed Central

    Kretz, Florian T A; Tandogan, Tamer; Khoramnia, Ramin; Auffarth, Gerd U

    2015-01-01

    AIM To evaluate the quality of vision in respect to high order aberrations and straylight perception after implantation of an aspheric, aberration correcting, monofocal intraocular lens (IOL). METHODS Twenty-one patients (34 eyes) aged 50 to 83y underwent cataract surgery with implantation of an aspheric, aberration correcting IOL (Tecnis ZCB00, Abbott Medical Optics). Three months after surgery they were examined for uncorrected (UDVA) and corrected distance visual acuity (CDVA), contrast sensitivity (CS) under photopic and mesopic conditions with and without glare source, ocular high order aberrations (HOA, Zywave II) and retinal straylight (C-Quant). RESULTS Postoperatively, patients achieved a postoperative CDVA of 0.0 logMAR or better in 97.1% of eyes. Mean values of high order abberations were +0.02±0.27 (primary coma components) and -0.04±0.16 (spherical aberration term). Straylight values of the C-Quant were 1.35±0.44 log which is within normal range of age matched phakic patients. The CS measurements under mesopic and photopic conditions in combination with and without glare did not show any statistical significance in the patient group observed (P≥0.28). CONCLUSION The implantation of an aspherical aberration correcting monofocal IOL after cataract surgery resulted in very low residual higher order aberration (HOA) and normal straylight. PMID:26309872

  12. Psychophysical Vision Simulation of Diffractive Bifocal and Trifocal Intraocular Lenses

    PubMed Central

    Brezna, Wolfgang; Lux, Kirsten; Dragostinoff, Nikolaus; Krutzler, Christian; Plank, Nicole; Tobisch, Rainer; Boltz, Agnes; Garhöfer, Gerhard; Told, Reinhard; Witkowska, Katarzyna; Schmetterer, Leopold

    2016-01-01

    Purpose The visual performance of monofocal, bifocal, and trifocal intraocular lenses was evaluated by human individuals using a vision simulator device. This allowed investigation of the visual impression after cataract surgery, without the need actually to implant the lenses. Methods The randomized, double-masked, three-way cross-over study was conducted on 60 healthy male and female subjects aged between 18 and 35 years. Visual acuity (Early Treatment Diabetic Retinopathy Study; ETDRS) and contrast sensitivity tests (Pelli-Robson) under different lighting conditions (luminosities from 0.14–55 cd/m2, mesopic to photopic) were performed at different distances. Results Visual acuity tests showed no difference for corrected distance visual acuity data of bi- and trifocal lens prototypes (P = 0.851), but better results for the trifocal than for the bifocal lenses at distance corrected intermediate (P = 0.021) and distance corrected near visual acuity (P = 0.044). Contrast sensitivity showed no differences between bifocal and trifocal lenses at the distant (P = 0.984) and at the near position (P = 0.925), but better results for the trifocal lens at the intermediate position (P = 0.043). Visual acuity and contrast sensitivity showed a strong dependence on luminosity (P < 0.001). Conclusions At all investigated distances and all lighting conditions, the trifocal lens prototype often performed better, but never worse than the bifocal lens prototype. Translational Relevance The vision simulator can fill the gap between preclinical lens development and implantation studies by providing information of the perceived vision quality after cataract surgery without implantation. This can reduce implantation risks and promotes the development of new lens concepts due to the cost effective test procedure. PMID:27777828

  13. Simulation of Blast Loading on an Ultrastructurally-based Computational Model of the Ocular Lens

    DTIC Science & Technology

    2012-10-01

    mechanisms of traumatic cataract forma - tion that may require cataract surgery (implantation of an intraocular lens (IOL)) are not well understood in...cornea and cutting through the iris and zonules. This was done by making a small incision with a diamond-head blade at the edge of the cornea and using

  14. Combining zonal refractive and diffractive aspheric multifocal intraocular lenses.

    PubMed

    Muñoz, Gonzalo; Albarrán-Diego, César; Javaloy, Jaime; Sakla, Hani F; Cerviño, Alejandro

    2012-03-01

    To assess visual performance with the combination of a zonal refractive aspheric multifocal intraocular lens (MIOL) (Lentis Mplus, Oculentis GmbH) and a diffractive aspheric MIOL (Acri.Lisa 366, Acri.Tech GmbH). This prospective interventional cohort study comprised 80 eyes from 40 cataract patients (mean age: 65.5±7.3 years) who underwent implantation of the Lentis Mplus MIOL in one eye and Acri.Lisa 366 MIOL in the fellow eye. The main outcome measures were refraction; monocular and binocular uncorrected and corrected distance, intermediate, and near visual acuities; monocular and binocular defocus curves; binocular photopic contrast sensitivity function compared to a monofocal intraocular lens (IOL) control group (40 age-matched pseudophakic patients implanted with the AR-40e [Abbott Medical Optics]); and quality of vision questionnaire. Binocular uncorrected visual acuities were 0.12 logMAR (0.76 decimal) or better at all distances measured between 6 m and 33 cm. The Lentis Mplus provided statistically significant better vision than the Acri.Lisa at distances between 2 m and 40 cm, and the Acri.Lisa provided statistically significant better vision than the Lentis Mplus at 33 cm. Binocular defocus curve showed little drop-off at intermediate distances. Photopic contrast sensitivity function for distance and near were similar to the monofocal IOL control group except for higher frequencies. Moderate glare (15%), night vision problems (12.5%), and halos (10%) were reported. Complete independence of spectacles was achieved by 92.5% of patients. The combination of zonal refractive aspheric and diffractive aspheric MIOLs resulted in excellent uncorrected binocular distance, intermediate, and near vision, with low incidence of significant photic phenomena and high patient satisfaction. Copyright 2012, SLACK Incorporated.

  15. Trabeculotomy combined with phacoemulsification and implantation of an intraocular lens for the treatment of primary open-angle glaucoma and coexisting cataract.

    PubMed

    Tanihara, H; Honjo, M; Inatani, M; Honda, Y; Ogino, N; Ueno, S; Negi, A; Ichioka, H; Mizoguchi, T; Matsumura, M; Nagata, M

    1997-10-01

    The authors previously reported the usefulness of trabeculotomy ab externo for the treatment of primary open-angle glaucoma in adult patients. In an attempt to elucidate the long-term risk-to-benefit ratio of this surgical modality in combination with cataract surgery, the authors conducted a retrospective study of the surgical effects and complications of a triple procedure: phacoemulsification, implantation (of an intraocular lens), and trabeculotomy (PIT). The authors conducted a retrospective study of patients treated with PIT at multiple hospitals. Intraocular pressure (IOP) and visual function data were obtained from patients after PIT as an initial surgical treatment in cases where antiglaucoma medications failed to resolve uncontrolled IOP (higher than 21 mm Hg). Included in this study were 96 eyes of 64 patients with primary open-angle glaucoma and coexisting cataract. The mean follow-up period was 22.6 +/- 14.7 months (range 3-56 months). In 94 (98%) of the 96 eyes, the IOP was well controlled, having achieved a level of 21 mm Hg or lower at the final examinations. The mean preoperative IOP of the 33 eyes that underwent the triple procedure using a single flap method (PIT-I) was 24.3 +/- 3.9 mm Hg, with an average of 2.1 +/- 1.1 medications. At the final examinations, the mean IOP had dropped to 16.0 +/- 1.2 mm Hg, with an average of 1.2 +/- 1.2 medications. The mean preoperative IOP of the 63 eyes that underwent the triple procedure using a double flap method (PIT-II) was 26.2 +/- 6.2 mm Hg, with an average of 1.9 +/- 1.2 medications. At the final examination, the mean IOP for this group was 15.6 +/- 2.9 mm Hg, with an average of 1.0 +/- 0.9 medications. The long-term results from this multicenter study showed that the triple procedure, PIT, can be useful and effective as an initial surgical treatment for open-angle glaucoma in glaucoma patients with coexisting cataract.

  16. The Results of Toric Intraocular Lens Implantation in Patients With Cataract and High Astigmatism After Penetrating Keratoplasty.

    PubMed

    Müftüoğlu, İlkay Klç; Akova, Yonca Aydn; Egrilmez, Sait; Yilmaz, Suzan Guven

    2016-03-01

    To evaluate the results of toric intraocular lens (IOL) implantation in patients with cataract and postpenetrating keratoplasty astigmatism. Seven eyes of 7 patients with cataract and more than 3.5 diopters (D) astigmatism following penetrating keratoplasty were included in this retrospective case series study. All of the eyes underwent phacoemulsification and Acrysof toric IOL (t5-t9) implantation at least 6 months later than the complete suture removal. Corrected visual acuity (CVA), manifest astigmatism, the keratometry measurements, and complications were assessed. The mean preoperative CVA significantly increased (0.7±0.3 [range: 0.3-1.3] logMAR to 0.1±0.04 [range: 0.05-0.15] logMAR; P<0.05) at mean 8.71±4.11 months after the surgery. The mean preoperative corneal astigmatism and the average manifest refractive astigmatism at the last visit were 5.4±0.9 D (range: 4.25-7 D) and 1.6±0.6 D (range: 0.5-2.5 D), respectively. The mean attempted cylinder correction at spectacle plane was 4.3±0.9 D (range: 2.4-4.7 D) whereas the mean cylinder correction was 4.6±0.5 D (range: 3.9-5.9 D), showing a slightly tendency for overcorrection. All eyes (100%) were within 1 D of predicted residual astigmatism. No complication occurred during the follow-up. Toric IOL implantation seems to be an effective, predictable, and safe procedure in patients with cataract formation and high astigmatism after penetrating keratoplasty.

  17. Eye growth in the second decade of life: implications for the implantation of a multifocal intraocular lens.

    PubMed

    Wilson, M Edward; Trivedi, Rupal H; Burger, Berdine M

    2009-12-01

    There is a growing interest in multifocal intraocular lens (IOL) implantation in children because they lose accommodation when a cataract is removed. Many have assumed that very little, if any, eye growth occurs in the second decade of life. Multifocal IOL implantation requires precise biometry to arrive at the correct IOL power for spectacle independence. If the eye grows and the refraction becomes myopic, spectacle dependence may return. Therefore, knowing when the eye has completed its growth is critical to the decision of when to implant a multifocal IOL. Ninety-eight eyes were analyzed retrospectively. Each had at least two axial length (AL) measurements using immersion A-scan ultrasound in the second decade of life. Globe AL was 23.36 +/- 1.52 mm at initial measurement and 23.89 +/- 1.64 mm at last measurement. Measurement data show variable growth throughout the second decade of life. Based on our data, a theoretical patient was constructed with an AL at age 10 of 23.11 mm, who would need an IOL power of 21.5 for emmetropia. That same patient would have an AL of 23.76 mm (IOL power of 19.5) at age 15 and 24.41 mm (IOL power of 17.5) at age 20. That is a 4-diopter change in the IOL power need. Axial eye growth continues throughout the second decade of life, at least to age 20. These data have important implications for the use of multifocal IOLs in the preteen and teenage years.

  18. Visual outcomes of patients bilaterally implanted with the extended range of vision intraocular lens: A prospective study

    PubMed Central

    Sachdev, Gitansha Shreyas; Ramamurthy, Shreyas; Sharma, Umesh; Dandapani, Ramamurthy

    2018-01-01

    Purpose: The aim of this study was to analyze the objective and subjective visual outcomes of patients bilaterally implanted with the extended range of vision intraocular lens (EROV IOL), the Tecnis Symfony. Methods: This was a prospective interventional case series conducted at a tertiary eye care hospital in South India. The study included patients with bilateral implantation of EROV IOLs. The uncorrected and corrected visual acuity for distance, intermediate, and near vision was recorded at 6 weeks and 6 months’ postoperative visit. A subjective questionnaire was administered to assess spectacle independence, photic phenomenon, and overall satisfaction. All data were recorded using Microsoft Excel worksheet. The analyses were performed using SPSS for windows software. Results: Our study included fifty patients with bilateral implantation of EROV IOLs. The mean age was 59.84 ± 11.68 years. The mean uncorrected binocular distance, intermediate, and near visual acuity (in standard decimal equivalent) was 0.89,0.99 and 0.99 respectively, at 6 months’ postoperative visit. Ninety-six percent of the patients did not require spectacles for distance and 98% of the patients were free from spectacles for intermediate and near vision. 94% of our patients perceived no or minimal photic phenomena such as glare and halos. The mean subjective patient satisfaction score (out of 10) for distance, intermediate, and near was 9, 10, and 9, respectively. Conclusion: The EROV IOLs demonstrated high levels of spectacle independence for distance, intermediate, and near vision. The incidence of photic phenomena observed was minimal with a high level of patient satisfaction. PMID:29480252

  19. Variations in retinal nerve fiber layer measurements on optical coherence tomography after implantation of trifocal intraocular lens.

    PubMed

    García-Bella, Javier; Martínez de la Casa, José M; Talavero González, Paula; Fernández-Vigo, José I; Valcarce Rial, Laura; García-Feijóo, Julián

    2018-01-01

    To establish the changes produced after implantation of a trifocal intraocular lens (IOL) on retinal nerve fiber layer measurements performed with Fourier-domain optical coherence tomography (OCT). This prospective study included 100 eyes of 50 patients with bilateral cataract in surgical range, no other associated ocular involvement, refractive errors between +5 and -5 spherical diopters, and less than 1.5 D of corneal astigmatism. The eyes were operated by phacoemulsification with implantation of 2 different trifocal IOLs (FineVision and AT LISA tri 839MP) in randomized equal groups. Cirrus OCT and Spectralis OCT were performed before surgery and 3 months later. Both analyzed the thickness of the nerve fiber layer and thickness divided by quadrants (6 in case of Spectralis and 4 in case of Cirrus HD). The mean age of patients was 67.5 ± 5.8 years. The global nerve fiber layer thickness measured with Spectralis OCT was 96.77 μm before surgery and 99.55 μm after. With Cirrus OCT, the global thickness was 85.29 μm before surgery and 89.77 μm after. Statistically significant differences in global thickness measurements between preimplantation and postimplantation of the IOL were found with both OCT in the 2 groups. Statistically significant differences were also found in temporal and superior quadrants. The implantation of a diffractive trifocal IOL alters the results of the optic nerve fiber layer on Fourier-domain OCT in these patients, which should be taken into account in the posterior study of these patients.

  20. Intra-ocular lens optical changes resulting from the loading of dexamethasone.

    PubMed

    Artigas, José M; García-Domene, M Carmen; Navea, Amparo; Botella, Pablo; Fernández, Eduardo

    2017-10-01

    To study the optical changes on hydrogel-silicone intraocular lenses (IOLs) resulting from loading them with dexamethasone. We used prototype hydrogel(pHEMA)-silicone IOLs and loaded the matrices with an anti-inflammatory drug (dexamethasone). The optical properties we analyzed experimentally were a) modulation transfer function (MTF); b) spectral transmission; c) diopter power. These determinations were performed on drug-loaded IOLs, IOLs that had released the drug, and IOLs that had not been drug-loaded. Loading a hydrogel-silicone IOL with dexamethasone results in impairment of its optical qualities, in particular its MTF and spectral transmission, but not dioptric power. However, once the drug has been released, it almost recovers its initial optical properties.

  1. Intra-ocular lens optical changes resulting from the loading of dexamethasone

    PubMed Central

    Artigas, José M.; García-Domene, M. Carmen; Navea, Amparo; Botella, Pablo; Fernández, Eduardo

    2017-01-01

    To study the optical changes on hydrogel-silicone intraocular lenses (IOLs) resulting from loading them with dexamethasone. We used prototype hydrogel(pHEMA)-silicone IOLs and loaded the matrices with an anti-inflammatory drug (dexamethasone). The optical properties we analyzed experimentally were a) modulation transfer function (MTF); b) spectral transmission; c) diopter power. These determinations were performed on drug-loaded IOLs, IOLs that had released the drug, and IOLs that had not been drug-loaded. Loading a hydrogel-silicone IOL with dexamethasone results in impairment of its optical qualities, in particular its MTF and spectral transmission, but not dioptric power. However, once the drug has been released, it almost recovers its initial optical properties. PMID:29082089

  2. Comparison of two different methods of preoperative marking for toric intraocular lens implantation: bubble marker versus pendulum marker

    PubMed Central

    Farooqui, Javed Hussain; Koul, Archana; Dutta, Ranjan; Shroff, Noshir Minoo

    2016-01-01

    AIM To compare the accuracy of two different methods of preoperative marking for toric intraocular lens (IOL) implantation, bubble marker versus pendulum marker, as a means of establishing the reference point for the final alignment of the toric IOL to achieve an outcome as close as possible to emmetropia. METHODS Toric IOLs were implanted in 180 eyes of 110 patients. One group (55 patients) had preoperative marking of both eyes done with bubble marker (ASICO AE-2791TBL) and the other group (55 patients) with pendulum marker (Rumex®3-193). Reference marks were placed at 3-, 6-, and 9-o'clock positions on the limbus. Slit-lamp photographs were analyzed using Adobe Photoshop (version 7.0). Amount of alignment error (in degrees) induced in each group was measured. RESULTS Mean absolute rotation error in the preoperative marking in the horizontal axis was 2.42±1.71 in the bubble marker group and 2.83±2.31in the pendulum marker group (P=0.501). Sixty percent of the pendulum group and 70% of the bubble group had rotation error ≤3 (P=0.589), and 90% eyes of the pendulum group and 96.7% of the bubble group had rotation error ≤5 (P=0.612). CONCLUSION Both preoperative marking techniques result in approximately 3 of alignment error. Both marking techniques are simple, predictable, reproducible and easy to perform. PMID:27275425

  3. A Prototype Antifungal Contact Lens

    PubMed Central

    Ciolino, Joseph B.; Hudson, Sarah P.; Mobbs, Ashley N.; Hoare, Todd R.; Iwata, Naomi G.; Fink, Gerald R.

    2011-01-01

    Purpose. To design a contact lens to treat and prevent fungal ocular infections. Methods. Curved contact lenses were created by encapsulating econazole-impregnated poly(lactic-co-glycolic) acid (PLGA) films in poly(hydroxyethyl methacrylate) (pHEMA) by ultraviolet photopolymerization. Release studies were conducted in phosphate-buffered saline at 37°C with continuous shaking. The contact lenses and their release media were tested in an antifungal assay against Candida albicans. Cross sections of the pre- and postrelease contact lenses were characterized by scanning electron microscopy and by Raman spectroscopy. Results. Econazole-eluting contact lenses provided extended antifungal activity against Candida albicans fungi. Fungicidal activity varied in duration and effectiveness depending on the mass of the econazole-PLGA film encapsulated in the contact lens. Conclusions. An econazole-eluting contact lens could be used as a treatment for fungal ocular infections. PMID:21527380

  4. Light-adjustable lens.

    PubMed Central

    Schwartz, Daniel M

    2003-01-01

    PURPOSE: First, to determine whether a silicone light-adjustable intraocular lens (IOL) can be fabricated and adjusted precisely with a light delivery device (LDD). Second, to determine the biocompatibility of an adjustable IOL and whether the lens can be adjusted precisely in vivo. METHODS: After fabrication of a light-adjustable silicone formulation, IOLs were made and tested in vitro for cytotoxicity, leaching, precision of adjustment, optical quality after adjustment, and mechanical properties. Light-adjustable IOLs were then tested in vivo for biocompatibility and precision of adjustment in a rabbit model. In collaboration with Zeiss-Meditec, a digital LDD was developed and tested to correct for higher-order aberrations in light-adjustable IOLs. RESULTS: The results establish that a biocompatible silicone IOL can be fabricated and adjusted using safe levels of light. There was no evidence of cytotoxicity or leaching. Testing of mechanical properties revealed no significant differences from commercial controls. Implantation of light-adjustable lenses in rabbits demonstrated- excellent biocompatibility after 6 months, comparable to a commercially available IOL. In vivo spherical (hyperopic and myopic) adjustment in rabbits was achieved using an analog light delivery system. The digital light delivery system was tested and achieved correction of higher-order aberrations. CONCLUSION: A silicone light-adjustable IOL and LDD have been developed to enable postoperative, noninvasive adjustment of lens power. The ability to correct higher-order aberrations in these materials has broad potential applicability for optimization of vision in patients undergoing cataract and refractive surgery. PMID:14971588

  5. Intraocular Lenses for the Treatment of Age-Related Cataracts

    PubMed Central

    2009-01-01

    Executive Summary Objective The objective of the report is to examine the comparative effectiveness and cost-effectiveness of various intraocular lenses (IOLs) for the treatment of age-related cataracts. Clinical Need: Target Population and Condition A cataract is a hardening and clouding of the normally transparent crystalline lens that may result in a progressive loss of vision depending on its size, location and density. The condition is typically bilateral, seriously compromises visual acuity and contrast sensitivity and increases glare. Cataracts can also affect people at any age, however, they usually occur as a part of the natural aging process. The occurrence of cataracts increases with age from about 12% at age 50 years, to 60% at age 70. In general, approximately 50% of people 65 year of age or older have cataracts. Mild cataracts can be treated with a change in prescription glasses, while more serious symptoms are treated by surgical removal of the cataract and implantation of an IOL. In Ontario, the estimated prevalence of cataracts increased from 697,000 in 1992 to 947,000 in 2004 (35.9% increase, 2.4% annual increase). The number of cataract surgeries per 1,000 individuals at risk of cataract increased from 64.6 in 1992 to 140.4 in 1997 (61.9% increase, 10.1% annual increase) and continued to steadily increase to 115.7 in 2004 (10.7% increase, 5.2% increase per year). Description of Technology/Therapy IOLs are classified either as monofocal, multifocal, or accommodative. Traditionally, monofocal (i.e.. fixed focusing power) IOLs are available as replacement lenses but their implantation can cause a loss of the eye’s accommodative capability (which allows variable focusing). Patients thus usually require eyeglasses after surgery for reading and near vision tasks. Multifocal IOLs aim to improve near and distant vision and obviate the need for glasses. Potential disadvantages include reduced contrast sensitivity, halos around lights and glare

  6. [Scheimpflug photography for the examination of phakic intraocular lenses].

    PubMed

    Baumeister, M

    2014-10-01

    High myopia phakic intraocular lenses (IOL) have become an established means of surgical correction for high ametropia. Scheimpflug photography is one of the methods which are frequently applied for postoperative examination of the implants. Results from published studies employing Scheimpflug photography for examination of anterior chamber angle-fixated, iris-fixated and sulcus-fixated phakic IOLs were evaluated. In several published studies Scheimpflug photography was used to examine the position of the implant and opacification of the crystalline lens. The results provided valuable evidence for the improvement of phakic IOL design. Scheimpflug photography offers an easy to use, rapid non-contact examination of phakic IOLs.

  7. The long term effect of an iris-supported lens on the endothelium.

    PubMed

    Galin, M A; Dotson, R S; Obstbaum, S A; Tuberville, A W

    1982-01-01

    A retrospective study of 104 eyes that had iris-supported Sputnik intraocular lenses implanted and no surgery in the fellow eye and a separate series of 30 implanted eyes whose second eyes underwent surgery but did not receive implants disclosed that endothelial cell densities in the eyes with implants decreased immediately after surgery and then continued to decrease at the same rate as those of the control eyes. There was no sudden decrease in the endothelial cell counts during follow-up periods ranging from three to seven years. The main cause of large cell losses immediately after surgery, and possibly long-term corneal decompensation, was surgical manipulation rather than the presence of this style of intraocular lens.

  8. Alkali metal for ultraviolet band-pass filter

    NASA Technical Reports Server (NTRS)

    Mardesich, Nick (Inventor); Fraschetti, George A. (Inventor); Mccann, Timothy A. (Inventor); Mayall, Sherwood D. (Inventor); Dunn, Donald E. (Inventor); Trauger, John T. (Inventor)

    1993-01-01

    An alkali metal filter having a layer of metallic bismuth deposited onto the alkali metal is provided. The metallic bismuth acts to stabilize the surface of the alkali metal to prevent substantial surface migration from occurring on the alkali metal, which may degrade optical characteristics of the filter. To this end, a layer of metallic bismuth is deposited by vapor deposition over the alkali metal to a depth of approximately 5 to 10 A. A complete alkali metal filter is described along with a method for fabricating the alkali metal filter.

  9. Comparison of posterior capsule opacification at 360-degree square edge hydrophilic and sharp edge hydrophobic acrylic intraocular lens in diabetic patients.

    PubMed

    Bai, Ling; Zhang, Jin; Chen, Ling; Ma, Ting; Liang, Hou-Cheng

    2015-01-01

    To compare posterior capsule opacification (PCO) degree and visual functions after phacoemulsification in eyes implanted with 360-degree square edge hydrophilic acrylic intraocular lens (IOL) (570C C-flex, Rayner) and sharp edge hydrophobic acrylic IOL (Sensar AR40e, AMO) in diabetic patients. Sixty diabetic patients underwent uneventful phacoemulsification and randomly implanted one of the two IOLs. The PCO value was measured by retroillumination photographs and Evaluation of Posterior Capsule Opacification (EPCO) 2000 image-analysis software at 1, 6, 12, and 24mo after surgery. Visual acuity, and contrast sensitivity in photopic and mesopic conditions were also examined at each follow up time point. The incidence of eye that required Nd:YAG laser posterior capsulotomy were also compared. There was not any statistically significant difference in PCO scores between Rayner C-flex 570C group and Sensar AR40e group at each follow up time point. Visual acuity, Nd:YAG capsulotomy incidence and contrast sensitivity also had no significant difference during the 24mo follow-up. For diabetic patients, Rayner 570C C-flex and Sensar AR40e IOLs are same effective for prevent PCO. The 360-degree square edge design maybe is a good alternative technique to improve PCO prevention.

  10. Implantation of refractive multifocal intraocular lens with a surface-embedded near section for cataract eyes complicated with a coexisting ocular pathology

    PubMed Central

    Ouchi, M; Kinoshita, S

    2015-01-01

    Purpose To evaluate the postoperative outcomes of cataract eyes complicated with coexisting ocular pathologies that underwent implantation of a refractive multifocal intraocular lens (MIOL) with a surface-embedded near section. Methods LENTIS MPlus (Oculentis GmbH) refractive MIOLs were implanted in 15 eyes with ocular pathologies other than cataract (ie, six high-myopia eyes with an axial length longer than 28 mm, two fundus albipunctatus eyes, two branch retinal-vein occlusion eyes, four glaucoma eyes (one with high myopia), and two keratoconus eyes). Uncorrected or corrected distance and near visual acuity (VA) (UDVA, UNVA, CDVA, and CNVA), contrast sensitivity, and defocus curve were measured at 1 day and 6 months postoperatively, and each patient completed a 6-month postoperative questionnaire regarding vision quality and eyeglass use. Results Thirteen eyes (87%) registered 0 or better in CDVA and 12 eyes (73%) registered better than 0 in CNVA. Contrast sensitivity in the eyes of all patients was comparable to that of normal healthy subjects. No patient required eyeglasses for distance vision, but three patients (20%) required them for near vision. No patient reported poor or very poor vision quality. Conclusion With careful case selection, sectorial refractive MIOL implantation is effective for treating cataract eyes complicated with ocular pathologies. PMID:25744442

  11. Implantation of refractive multifocal intraocular lens with a surface-embedded near section for cataract eyes complicated with a coexisting ocular pathology.

    PubMed

    Ouchi, M; Kinoshita, S

    2015-05-01

    To evaluate the postoperative outcomes of cataract eyes complicated with coexisting ocular pathologies that underwent implantation of a refractive multifocal intraocular lens (MIOL) with a surface-embedded near section. LENTIS MPlus (Oculentis GmbH) refractive MIOLs were implanted in 15 eyes with ocular pathologies other than cataract (ie, six high-myopia eyes with an axial length longer than 28 mm, two fundus albipunctatus eyes, two branch retinal-vein occlusion eyes, four glaucoma eyes (one with high myopia), and two keratoconus eyes). Uncorrected or corrected distance and near visual acuity (VA) (UDVA, UNVA, CDVA, and CNVA), contrast sensitivity, and defocus curve were measured at 1 day and 6 months postoperatively, and each patient completed a 6-month postoperative questionnaire regarding vision quality and eyeglass use. Thirteen eyes (87%) registered 0 or better in CDVA and 12 eyes (73%) registered better than 0 in CNVA. Contrast sensitivity in the eyes of all patients was comparable to that of normal healthy subjects. No patient required eyeglasses for distance vision, but three patients (20%) required them for near vision. No patient reported poor or very poor vision quality. With careful case selection, sectorial refractive MIOL implantation is effective for treating cataract eyes complicated with ocular pathologies.

  12. Comparison of posterior capsule opacification at 360-degree square edge hydrophilic and sharp edge hydrophobic acrylic intraocular lens in diabetic patients

    PubMed Central

    Bai, Ling; Zhang, Jin; Chen, Ling; Ma, Ting; Liang, Hou-Cheng

    2015-01-01

    AIM To compare posterior capsule opacification (PCO) degree and visual functions after phacoemulsification in eyes implanted with 360-degree square edge hydrophilic acrylic intraocular lens (IOL) (570C C-flex, Rayner) and sharp edge hydrophobic acrylic IOL (Sensar AR40e, AMO) in diabetic patients. METHODS Sixty diabetic patients underwent uneventful phacoemulsification and randomly implanted one of the two IOLs. The PCO value was measured by retroillumination photographs and Evaluation of Posterior Capsule Opacification (EPCO) 2000 image-analysis software at 1, 6, 12, and 24mo after surgery. Visual acuity, and contrast sensitivity in photopic and mesopic conditions were also examined at each follow up time point. The incidence of eye that required Nd:YAG laser posterior capsulotomy were also compared. RESULTS There was not any statistically significant difference in PCO scores between Rayner C-flex 570C group and Sensar AR40e group at each follow up time point. Visual acuity, Nd:YAG capsulotomy incidence and contrast sensitivity also had no significant difference during the 24mo follow-up. CONCLUSION For diabetic patients, Rayner 570C C-flex and Sensar AR40e IOLs are same effective for prevent PCO. The 360-degree square edge design maybe is a good alternative technique to improve PCO prevention. PMID:26309870

  13. Temporal multiplexing to simulate multifocal intraocular lenses: theoretical considerations

    PubMed Central

    Akondi, Vyas; Dorronsoro, Carlos; Gambra, Enrique; Marcos, Susana

    2017-01-01

    Fast tunable lenses allow an effective design of a portable simultaneous vision simulator (SimVis) of multifocal corrections. A novel method of evaluating the temporal profile of a tunable lens in simulating different multifocal intraocular lenses (M-IOLs) is presented. The proposed method involves the characteristic fitting of the through-focus (TF) optical quality of the multifocal component of a given M-IOL to a linear combination of TF optical quality of monofocal lenses viable with a tunable lens. Three different types of M-IOL designs are tested, namely: segmented refractive, diffractive and refractive extended depth of focus. The metric used for the optical evaluation of the temporal profile is the visual Strehl (VS) ratio. It is shown that the time profiles generated with the VS ratio as a metric in SimVis resulted in TF VS ratio and TF simulated images that closely matched the TF VS ratio and TF simulated images predicted with the M-IOL. The effects of temporal sampling, varying pupil size, monochromatic aberrations, longitudinal chromatic aberrations and temporal dynamics on SimVis are discussed. PMID:28717577

  14. Cataract, phacoemulsification and intraocular pressure: Is the anterior segment anatomy the missing piece of the puzzle?

    PubMed

    Masis Solano, Marisse; Lin, Shan C

    2018-01-29

    Cataract extraction is a safe and effective surgery that has a lowering effect on the intraocular pressure. The specific mechanisms for this effect are still unclear. A direct inflammatory effect on the trabecular meshwork, alteration of the blood aqueous barrier, changes in the ciliary body and mechanical changes of the anterior segment anatomy are the key to understand cataract surgery and it's effects on aqueous humor dynamics. Additionally, with the advent of AS OCT, changes in the anterior segment of the eye have been studied and several parameters (such as lens vault, angle opening distance and anterior chamber depth) have been identified as predictors of intraocular pressure change. In eyes with narrow angles there is a greater drop in intraocular pressure after cataract surgery and it is correlated with parameters related to anterior chamber space. It is safe to affirm that cataract surgery is an important part of the modern glaucoma treatment and evidence should be analyzed as part of a bigger picture in order to more accurately understand its clinical relevance. Copyright © 2018. Published by Elsevier Ltd.

  15. Intraocular lens power calculations for cataract surgery after phototherapeutic keratectomy in granular corneal dystrophy type 2.

    PubMed

    Jung, Se Hwan; Han, Kyung Eun; Sgrignoli, Bradford; Kim, Tae-Im; Lee, Hyung Keun; Kim, Eung Kweon

    2012-10-01

    To investigate the predictability of various intraocular lens (IOL) power calculation methods in granular corneal dystrophy type 2 (GCD2) with prior phototherapeutic keratectomy (PTK) and to suggest the more predictable IOL power calculation method. Medical records of 20 eyes from 16 patients with GCD2, all having undergone cataract surgery after PTK, were retrospectively evaluated. Postoperative cataract refractive errors were compared with target diopters (D) using IOL power calculation methods as follows: 1) myopic and 2) hyperopic Haigis-L formula in IOLMaster (Carl Zeiss Meditec); 3) SRK/T formula using 4.5-mm zone Holladay equivalent keratometry readings (EKRs) (single-K Holladay EKRs method); 4) central keratometry power of true net power map in the Pentacam system (Oculus Optikgeräte GmbH); and 5) clinical history, Aramberri double-K, and double-K Holladay EKRs methods. Topographic status of corneal curvature after PTK was evaluated. Fourteen (70%) of 20 eyes showed central island formation after PTK. When central island was present, the mean absolute error (MAE) using the hyperopic Haigis-L formula was 0.25±0.15 D. When central island was not present, the myopic Haigis-L formula showed MAE of 0.33±0.16 D. When central island formation and IOLMaster keratometry underestimation were present, the hyperopic Haigis-L formula showed the least MAE of 0.26±0.08 D when switching the IOL-Master keratometry values equal to 4.5-mm zone Holladay EKRs. In planning for cataract surgery after PTK in GCD2, topographic analysis for central island formation is necessary. With or without central island formation, the hyperopic or myopic Haigis-L formula can be applied. When IOLMaster keratometry shows underestimation, the Haigis-L formula using 4.5-mm zone Holladay EKRs can be considered. Copyright 2012, SLACK Incorporated.

  16. Comparative Efficacy of the New Optical Biometer on Intraocular Lens Power Calculation (AL-Scan versus IOLMaster).

    PubMed

    Ha, Ahnul; Wee, Won Ryang; Kim, Mee Kum

    2018-05-15

    To evaluate the agreement in axial length (AL), keratometry, and anterior chamber depth measurements between AL-Scan and IOLMaster biometers and to compare the efficacy of the AL-Scan on intraocular lens (IOL) power calculations and refractive outcomes with those obtained by the IOLMaster. Medical records of 48 eyes from 48 patients who underwent uneventful phacoemulsification and IOL insertion were retrospectively reviewed. One of the two types of monofocal aspheric IOLs were implanted (Tecnis ZCB00 [Tecnis, n = 34] or CT Asphina 509M [Asphina, n = 14]). Two different partial coherence interferometers measured and compared AL, keratometry (2.4 mm), anterior chamber depth, and IOL power calculations with SRK/T, Hoffer Q, Holladay2, and Haigis formulas. The difference between expected and actual final refractive error was compared as refractive mean error (ME), refractive mean absolute error (MAE), and median absolute error (MedAE). AL measured by the AL-Scan was shorter than that measured by the IOLMaster (p = 0.029). The IOL power of Tecnis did not differ between the four formulas; however, the Asphina measurement calculated using Hoffer Q for the AL-Scan was lower (0.28 diopters, p = 0.015) than that calculated by the IOLMaster. There were no statistically significant differences between the calculations by MAE and MedAE for the four formulas in either IOL. In SRK/T, ME in Tecnis-inserted eyes measured by AL-Scan showed a tendency toward myopia (p = 0.032). Measurement by AL-Scan provides reliable biometry data and power calculations compared to the IOLMaster; however, refractive outcomes of Tecnis-inserted eyes by AL-Scan calculated using SRK/T can show a slight myopic tendency. © 2018 The Korean Ophthalmological Society.

  17. Morphology of contact lens-induced conjunctival epithelial flaps: a pilot study.

    PubMed

    Bergmanson, Jan P G; Tukler, Johanna; Leach, Norman E; Alabdelmoneam, Mussaed; Miller, William L

    2012-08-01

    Conjunctival epithelial flap (CEF) is a conjunctival condition most commonly seen in silicone hydrogel contact lens wearers. This study utilized impression cytology to investigate the cellular composition and health of CEFs. Nine (9) subjects were enrolled - 3 non-lens wearers, 3 contact lens wearers without CEF, and 3 contact lens wearers with CEFs wearing 8.4/13.8 lotrafilcon A lenses. Impression cytology samples were collected from the flap or similar locations, if CEF was absent, using rectangular 5 mm × 2 mm Millipore HAWP02500 membrane filters. The filters were gently pressed onto the conjunctiva, subsequently fixed in 95% alcohol, stained with hematoxylin-eosin and evaluated under an Olympus IX70 microscope. Measurements of the longest cell and nucleus dimensions were measured on 40 cells from each filter by utilizing NIH Image 1.63. CEF consisted of multilayers of epithelial and goblet cells and were devoid of inflammatory cells, basement membrane material and stromal tissue. The cytoplasmic and nuclear dimensions were similar within the groups and the cytoplasm-to-nucleus ratio was not different between the flap group and the non-lens wearing group. The CEF appeared to be formed by healthy epithelial and goblet cells that have been dislocated from their normal location along the conjunctival surface by the lens edge. No inflammatory cells were present in this contact lens induced condition, which is reported to be associated most commonly with the silicone hydrogel material. Copyright © 2012 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  18. Carnosine ameliorates lens protein turbidity formations by inhibiting calpain proteolysis and ultraviolet C-induced degradation.

    PubMed

    Liao, Jiahn-Haur; Lin, I-Lin; Huang, Kai-Fa; Kuo, Pei-Ting; Wu, Shih-Hsiung; Wu, Tzu-Hua

    2014-06-25

    Carnosine (CAR) is an endogenous peptide and present in lens, but there is little evidence for its effectiveness in calpain-induced proteolysis inhibition and its differential effects toward different wavelengths of ultraviolet (UV) irradiation. This study aimed to develop three in vitro cataract models to compare the mechanisms underlying the protective activities of CAR. Crude crystallins extracted from porcine lenses were used for antiproteolysis assays, and purified γ-crystallins were used for anti-UV assays. The turbidity in those in vitro models mimics cataract formation and was assayed by measuring optical density (OD) at 405 nm. The effectiveness of CAR on calpain-induced proteolysis was studied at 37 and 58 °C. Patterns of proteins were then analyzed by SDS-PAGE. The turbidity was reduced significantly (p<0.05) at 60 min measurements with the increased concentration of CAR (10-300 mM). SDS-PAGE showed that the decreased intensities at both ∼28 and ∼30 kDa protein bands in heat-enhanced assays were ameliorated by CAR at ≥10 mM concentrations. In UV-B studies, CAR (200, 300 mM) reduced the turbidity of γ-crystallin significantly (p<0.05) at 6 h observations. The turbidity of samples containing γ-crystallins was ameliorated while incubated with CAR (100, 300 mM) significantly (p<0.05) following 4 h of exposure to UV-C. SDS-PAGE showed that the presence of CAR reduced UV-B-induced aggregation of γ-crystallins at ∼44 kDa and resulted in less loss of γ-crystallin following UV-C exposure. The result of modeling also suggests that CAR acts as an inhibitor of calpain. In conclusion, CAR protects lens proteins more readily by inhibiting proteolysis and UV-C-induced degradation than aggregation induced by UV-B irradiation.

  19. Trade-offs in ecosystem impacts from nanomaterial versus organic chemical ultraviolet filters in sunscreens.

    PubMed

    Hanigan, David; Truong, Lisa; Schoepf, Jared; Nosaka, Takayuki; Mulchandani, Anjali; Tanguay, Robert L; Westerhoff, Paul

    2018-08-01

    Both nanoparticulate (nZnO and nTiO 2 ) and organic chemical ultraviolet (UV) filters are active ingredients in sunscreen and protect against skin cancer, but limited research exists on the environmental effects of sunscreen release into aquatic systems. To examine the trade-offs of incorporating nanoparticles (NPs) into sunscreens over the past two decades, we targeted endpoints sensitive to the potential risks of different UV filters: solar reactive oxygen production in water and disruption of zebrafish embryo development. First, we developed methodology to extract nanoparticles from sunscreens with organic solvents. Zebrafish embryos exposed to parts-per-million NPs used in sunscreens displayed limited toxicological effects; nZnO particles appeared to be slightly more toxic than nTiO 2 at the highest concentrations. In contrast, seven organic UV filters did not affect zebrafish embryogenesis at or near aqueous solubility. Second, to simulate potent photo-initiated reactions upon release into water, we examined methylene blue (MB) degradation under UV light. nTiO 2 from sunscreen caused 10 times faster MB loss than nZnO and approached the photocatalytic degradation rate of a commercial nTiO 2 photocatalysts (P25). Organic UV filters did not cause measurable MB degradation. Finally, we estimated that between 1 and 10 ppm of sunscreen NPs in surface waters could produce similar steady state hydroxyl radical concentrations as naturally occurring fluvic acids under sunlight irradiation. Incorporation of NPs into sunscreen may increase environmental concentrations of reactive oxygen, albeit to a limited extent, which can influence transformation of dissolved substances and potentially affect ecosystem processes. Copyright © 2018 Elsevier Ltd. All rights reserved.

  20. Pupil Influence on the Visual Outcomes of a New-Generation Multifocal Toric Intraocular Lens With a Surface-Embedded Near Segment.

    PubMed

    Wang, Mengmeng; Corpuz, Christine Carole C; Huseynova, Tukezban; Tomita, Minoru

    2016-02-01

    To evaluate the influences of preoperative pupil parameters on the visual outcomes of a new-generation multifocal toric intraocular lens (IOL) model with a surface-embedded near segment. In this prospective study, patients with cataract had phacoemulsification and implantation of Lentis Mplus toric LU-313 30TY IOLs (Oculentis GmbH, Berlin, Germany). The visual and optical outcomes were measured and compared preoperatively and postoperatively. The correlations between preoperative pupil parameters (diameter and decentration) and 3-month postoperative visual outcomes were evaluated using the Spearman's rank-order correlation coefficient (Rs) for the nonparametric data. A total of 27 eyes (16 patients) were enrolled into the current study. Statistically significant improvements in visual and refractive performances were found after the implantation of Lentis Mplus toric LU-313 30TY IOLs (P < .05). Statistically significant correlations were present between preoperative pupil diameters and postoperative visual acuities (Rs > 0; P < .05). Patients with a larger pupil always have better postoperative visual acuities. Meanwhile, there was no statistically significant correlation between pupil decentration and visual acuities (P > .05). Lentis Mplus toric LU-313 30TY IOLs provided excellent visual and optical performances during the 3-month follow-up. The preoperative pupil size is an important parameter when this toric multifocal IOL model is contemplated for surgery. Copyright 2016, SLACK Incorporated.

  1. Clinical Evaluation of Functional Vision of +1.5 Diopters near Addition, Aspheric, Rotational Asymmetric Multifocal Intraocular Lens

    PubMed Central

    Khoramnia, Rahmin; Attia, Mary Safwat; Koss, Michael Janusz; Linz, Katharina; Auffarth, Gerd Uwe

    2016-01-01

    Purpose To evaluate postoperative outcomes and visual performance in intermediate distance after implantation of a +1.5 diopters (D) addition, aspheric, rotational asymmetric multifocal intraocular lens (MIOL). Methods Patients underwent bilateral cataract surgery with implantation of an aspheric, asymmetric MIOL with +1.5 D near addition. A complete ophthalmological examination was performed preoperatively and 3 months postoperatively. The main outcome measures were monocular and binocular uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected intermediate visual acuity (UIVA), distance corrected intermediate visual acuity (DCIVA), uncorrected near visual acuity (UNVA) and distance corrected keratometry, and manifest refraction. The Salzburg Reading Desk was used to analyze unilateral and bilateral functional vision with uncorrected and corrected reading acuity, reading distance, reading speed, and the smallest log-scaled print size that could be read effectively at near and intermediate distances. Results The study comprised 60 eyes of 30 patients (mean age, 68.30 ± 9.26 years; range, 34 to 80 years). There was significant improvement in UDVA and CDVA. Mean UIVA was 0.01 ± 0.09 logarithm of the minimum angle of resolution (logMAR) and mean DCIVA was -0.02 ± 0.11 logMAR. In Salzburg Reading Desk analysis for UIVA, the mean subjective intermediate distance was 67.58 ± 8.59 cm with mean UIVA of -0.02 ± 0.09 logMAR and mean word count of 96.38 ± 28.32 words/min. Conclusions The new aspheric, asymmetric, +1.5 D near addition MIOL offers good results for distance visual function in combination with good performance for intermediate distances and functional results for near distance. PMID:27729759

  2. Clinical Evaluation of Functional Vision of +1.5 Diopters near Addition, Aspheric, Rotational Asymmetric Multifocal Intraocular Lens.

    PubMed

    Kretz, Florian Tobias Alwin; Khoramnia, Rahmin; Attia, Mary Safwat; Koss, Michael Janusz; Linz, Katharina; Auffarth, Gerd Uwe

    2016-10-01

    To evaluate postoperative outcomes and visual performance in intermediate distance after implantation of a +1.5 diopters (D) addition, aspheric, rotational asymmetric multifocal intraocular lens (MIOL). Patients underwent bilateral cataract surgery with implantation of an aspheric, asymmetric MIOL with +1.5 D near addition. A complete ophthalmological examination was performed preoperatively and 3 months postoperatively. The main outcome measures were monocular and binocular uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected intermediate visual acuity (UIVA), distance corrected intermediate visual acuity (DCIVA), uncorrected near visual acuity (UNVA) and distance corrected keratometry, and manifest refraction. The Salzburg Reading Desk was used to analyze unilateral and bilateral functional vision with uncorrected and corrected reading acuity, reading distance, reading speed, and the smallest log-scaled print size that could be read effectively at near and intermediate distances. The study comprised 60 eyes of 30 patients (mean age, 68.30 ± 9.26 years; range, 34 to 80 years). There was significant improvement in UDVA and CDVA. Mean UIVA was 0.01 ± 0.09 logarithm of the minimum angle of resolution (logMAR) and mean DCIVA was -0.02 ± 0.11 logMAR. In Salzburg Reading Desk analysis for UIVA, the mean subjective intermediate distance was 67.58 ± 8.59 cm with mean UIVA of -0.02 ± 0.09 logMAR and mean word count of 96.38 ± 28.32 words/min. The new aspheric, asymmetric, +1.5 D near addition MIOL offers good results for distance visual function in combination with good performance for intermediate distances and functional results for near distance.

  3. Robot-assisted intraocular surgery: development of the IRISS and feasibility studies in an animal model

    PubMed Central

    Rahimy, E; Wilson, J; Tsao, T-C; Schwartz, S; Hubschman, J-P

    2013-01-01

    Purpose The aim of this study is to develop a novel robotic surgical platform, the IRISS (Intraocular Robotic Interventional and Surgical System), capable of performing both anterior and posterior segment intraocular surgery, and assess its performance in terms of range of motion, speed of motion, accuracy, and overall capacities. Patients and methods To test the feasibility of performing ‘bimanual' intraocular surgical tasks using the IRISS, we defined four steps out of typical anterior (phacoemulsification) and posterior (pars plana vitrectomy (PPV)) segment surgery. Selected phacoemulsification steps included construction of a continuous curvilinear capsulorhexis and cortex removal in infusion–aspiration (I/A) mode. Vitrectomy steps consisted of performing a core PPV, followed by aspiration of the posterior hyaloid with the vitreous cutter to induce a posterior vitreous detachment (PVD) assisted with triamcinolone, and simulation of the microcannulation of a temporal retinal vein. For each evaluation, the duration and the successful completion of the task with or without complications or involuntary events was assessed. Results Intraocular procedures were successfully performed on 16 porcine eyes. Four eyes underwent creation of a round, curvilinear anterior capsulorhexis without radialization. Four eyes had I/A of lens cortical material completed without posterior capsular tear. Four eyes completed 23-gauge PPV followed by successful PVD induction without any complications. Finally, simulation of microcannulation of a temporal retinal vein was successfully achieved in four eyes without any retinal tears/perforations noted. Conclusion Robotic-assisted intraocular surgery with the IRISS may be technically feasible in humans. Further studies are pending to improve this particular surgical platform. PMID:23722720

  4. Effect of Myopic Defocus on Visual Acuity after Phakic Intraocular Lens Implantation and Wavefront-guided Laser in Situ Keratomileusis

    PubMed Central

    Kamiya, Kazutaka; Shimizu, Kimiya; Igarashi, Akihito; Kawamorita, Takushi

    2015-01-01

    This study aimed to investigate the effect of myopic defocus on visual acuity after phakic intraocular lens (IOL) implantation and wavefront-guided laser in situ keratomileusis (wfg-LASIK). Our prospective study comprised thirty eyes undergoing posterior chamber phakic IOL implantation and 30 eyes undergoing wfg-LASIK. We randomly measured visual acuity under myopic defocus after cycloplegic and non-cycloplegic correction. We also calculated the modulation transfer function by optical simulation and estimated visual acuity from Campbell & Green’s retinal threshold curve. Visual acuity in the phakic IOL group was significantly better than that in the wfg-LASIK group at myopic defocus levels of 0, –1, and –2 D (p < 0.001, p < 0.001, and p = 0.02, Mann-Whitney U-test), but not at a defocus of –3 D (p = 0.30). Similar results were also obtained in a cycloplegic condition. Decimal visual acuity values at a myopic defocus of 0, −1, −2, and -3 D by optical simulation were estimated to be 1.95, 1.21, 0.97, and 0.75 in the phakic IOL group, and 1.39, 1.11, 0.94, and 0.71 in the wfg-LASIK group, respectively. From clinical and optical viewpoints, phakic IOL implantation was superior to wfg-LASIK in terms of the postoperative visual performance, even in the presence of low to moderate myopic regression. PMID:25994984

  5. Measurement device for high-precision spectral transmittance of solar blind filter

    NASA Astrophysics Data System (ADS)

    Wang, Yan; Qian, Yunsheng; Lv, Yang; Feng, Cheng; Liu, Jian

    2017-02-01

    In order to measure spectral transmittance of solar-blind filter ranging from ultraviolet to visible light accurately, a high-precision filter transmittance measuring system based on the ultraviolet photomultiplier is developed. The calibration method is mainly used to measure transmittance in this system, which mainly consists of an ultraviolet photomultiplier as core of the system and a lock-in amplifier combined with an optical modulator as the aided measurement for the system. The ultraviolet photomultiplier can amplify the current signal through the filter and have the characteristics of low dark current and high luminance gain. The optical modulator and the lock-in amplifier can obtain the signal from the photomultiplier and inhibit dark noise and spurious signal effectively. Through these two parts, the low light passing through the filters can be detected and we can calculate the transmittance by the optical power detected. Based on the proposed system, the limit detection of the transmittance can reach 10-12, while the result of the conventional approach is merely 10-6. Therefore, the system can make an effective assessment of solar blind ultraviolet filters.

  6. Accidental injections of dexamethasone intravitreal implant (Ozurdex) into the crystalline lens.

    PubMed

    Coca-Robinot, Javier; Casco-Silva, Bruno; Armadá-Maresca, Felix; García-Martínez, Jesús

    2014-01-01

    To describe the side effects and management after inadvertent injection of a dexamethasone implant (Ozurdex) into the crystalline lens. Two case reports. Two patients with macular edema due to unilateral retinal vein occlusion were scheduled for an intravitreal injection of Ozurdex. During the procedure, the implant was accidentally injected into the crystalline lens. Both patients developed cataracts during the course of several weeks and in both there was an intraocular pressure (IOP) increase, which required treatment with topical hypotensives. Macular edema improved only slightly. Cataract surgery with uneventful removal of the implant was performed 3 (case 1) and 6 months (case 2) after the injection. After inadvertent injection of Ozurdex into the crystalline lens, cataract surgery with removal of the implant should be performed as soon as possible in order to avoid IOP increase and so that the underlying condition may be treated adequately.

  7. National Apprenticeship and Training Standards for Optical Technician (Contact Lens Technician).

    ERIC Educational Resources Information Center

    Manpower Administration (DOL), Washington, DC. Bureau of Apprenticeship and Training.

    A statement of policy of the Contact Lens Society of America regarding contact lens filters is followed by national apprenticeship and training standards for optical technicians approved and adopted by the Contact Lens Society of America in accordance with the basic standards recommended by the Bureau of Apprenticeship and Training of the…

  8. Rotationally asymmetric multifocal IOL implantation with and without capsular tension ring: refractive and visual outcomes and intraocular optical performance.

    PubMed

    Alió, Jorge L; Plaza-Puche, Ana B; Piñero, David P

    2012-04-01

    To ascertain whether the refractive, visual, and intraocular optical quality outcomes of a rotationally asymmetric multifocal intraocular lens (IOL) are enhanced by the use of a capsular tension ring. Ninety consecutive eyes from 53 patients (age range: 36 to 82 years) were divided into two groups: the no ring group comprised 43 eyes implanted with the multifocal rotationally asymmetric Lentis Mplus LS-312 (Oculentis GmbH) without a capsular tension ring; and the ring group comprised 47 eyes with the same IOL with a capsular tension ring. Distance and near visual acuity and refractive outcomes were evaluated pre- and postoperatively. Contrast sensitivity, intraocular aberrations, and defocus curve were evaluated postoperatively. Significant postoperative differences between groups were found in sphere, spherical equivalent refraction, and near addition (P<.02). Regarding defocus curve, significantly better visual acuity was present in eyes with the capsular tension ring for intermediate vision conditions (P<.05). Intraocular aberrometry did not differ significantly between groups (P<.09). Refractive predictability and intermediate visual outcomes with the Lentis Mplus LS-312 IOL improved significantly when implanted in combination with a capsular tension ring. Copyright 2012, SLACK Incorporated.

  9. Seasonal and diurnal variation of organic ultraviolet filters from personal care products used along the Japanese coast.

    PubMed

    Sankoda, Kenshi; Murata, Kotaro; Tanihata, Mai; Suzuki, Kengo; Nomiyama, Kei; Shinohara, Ryota

    2015-02-01

    This study aimed to investigate the behavior of organic ultraviolet (UV) filters released by recreational activities along the Japanese coastline. Seasonal variations of organic UV filters in seawater were investigated at four different recreational beaches (Mogushi, Wakamiya, Tsurugahama, and Otachimisaki beaches) in both summer (July through August) and winter (December). Moreover, short time scale diurnal changes were monitored at Otachimisaki beach in summer. Of the four sunscreen agents tested in this study, two agents-2-ethylhexyl-4-methoxycinnamate (EHMC) and 2-ethylhexyl salicylate (EHS)-were detected in all samples, whereas octyl-dimethyl-p-aminobenzonic acid and 3-(4-methylbenzylidene)-camphor were lower than detection limits. In particular, EHMC, one of the most popular organic UV filters, was dominant. The highest concentration of EHMC was observed at 1,080 ng L(-1), a level that exceeds those of previous studies. Both EHMC and EHS concentrations showed significant (p < 0.05) seasonal variations with advancing summer suggesting direct input from recreational activities. The subsequent examination showed short time scale diurnal changes of organic UV filters on the beach. The results showed that diurnal changes in EHMC concentrations were correlated to the number of bathers. EHMC concentrations increased during the afternoon and decreased during the night, although complete attenuation during the night did not occur. EHMC persists along the coast due to low mobility and may persist the next day. This is the first study to show the natural attenuation behavior of organic UV filters along recreational beaches.

  10. Analysis of patients with good uncorrected distance and near vision after monofocal intraocular lens implantation.

    PubMed

    Nanavaty, Mayank A; Vasavada, Abhay R; Patel, Anil S; Raj, Shetal M; Desai, Tejas H

    2006-07-01

    To analyze factors contributing to uncorrected visual acuity of at least 6/12 for distance and at least J4 for near (pseudoaccommodation) after monofocal intraocular lens (IOL) implantation. Iladevi Cataract and IOL Research Center, Ahmedabad, India. In a case-controlled study of 30 eyes (30 patients) that had phacoemulsification, those with pseudoaccommodation were assigned to cases and 30 eyes (30 patients) without pseudoaccommodation were designated as controls. Controls were matched by identical best corrected visual acuity, age, and postoperative duration. Subjective refraction was done with retinoscopy. Factors analyzed included corneal astigmatism, pupil size, axial IOL movement, amplitude of accommodation, axial length (AL), and age. Corneal astigmatism was noted on topography and interpreted as against the rule (ATR) (180 +/- 15 degrees), with the rule (WTR) (90 +/- 15 degrees), and oblique (OB) (45/135 +/- 30 degrees). Pupil size was noted on topographic display and AL and anterior chamber depth (ACD) on immersion A-scan. The axial IOL movement was calculated as the difference in ACD after instillation of cyclopentolate 1% (Cyclopent) and subsequently pilocarpine nitrate 2% (Carpinol) at separate visits, and amplitude of accommodation was measured with static and dynamic retinoscopy. Multivariate logistic regression and odds ratio with 95% confidence intervals were determined. Mean spherical equivalent was -0.45 +/- 0.63 diopter (D) in cases and -0.35 +/- 0.83 D (P = .61) in controls. Multivariate logistic regression in cases versus controls: corneal astigmatism (ATR versus WTR and OB collectively): 10.19 [1.8,57.44], P = .009; pupil size: 0.45 [0.07,2.71], P = .38; axial IOL movement: 1.39 [0.51,0.77], P = .514; amplitude of accommodation: 2.95 [0.93,9.3], P = .065; AL: 0.55 [0.29,1.02], P = .058; and age: 0.98 [0.5,1.95], P = .963. The study suggests a significant role of ATR corneal astigmatism in good uncorrected distance and near vision after

  11. Estimation of safe exposure time from an ophthalmic operating microscope with regard to ultraviolet radiation and blue-light hazards to the eye

    NASA Astrophysics Data System (ADS)

    Michael, Ralph; Wegener, Alfred

    2004-08-01

    Hazards from the optical radiation of an operating microscope that cause damage at the corneal, lenticular, and retinal levels were investigated; we considered, in particular, ultraviolet radiation (UVR) and blue light. The spectral irradiance from a Zeiss operation microscope OPMI VISU 200 was measured in the corneal plane between 300 and 1100 nm. Effective irradiance and radiance were calculated with relative spectral effectiveness data from the American Conference for Governmental and Industrial Hygienists. Safe exposure time to avoid UVR injury to the lens and cornea was found to be 2 h without a filter, 4 h with a UVR filter, 200 h with a yellow filter, and 400 h with a filter combination. Safe exposure time to avoid retinal photochemical injury was found to be 3 min without a filter and with a UVR filter, 10 min with a yellow filter, and 49 min with a filter combination. The effective radiance limit for retinal thermal injury was not exceeded. The hazard due to the UVR component from the operating microscope is not critical, and operation time can be safely prolonged with the use of appropriate filters. The retinal photochemical hazard appears critical without appropriate filters, permitting only some minutes of safe exposure time. The calculated safe exposure times are for worst-case conditions and maximal light output and include a safety factor.

  12. Estimation of safe exposure time from an ophthalmic operating microscope with regard to ultraviolet radiation and blue-light hazards to the eye.

    PubMed

    Michael, Ralph; Wegener, Alfred

    2004-08-01

    Hazards from the optical radiation of an operating microscope that cause damage at the corneal, lenticular, and retinal levels were investigated; we considered, in particular, ultraviolet radiation (UVR) and blue light. The spectral irradiance from a Zeiss operation microscope OPMI VISU 200 was measured in the corneal plane between 300 and 1100 nm. Effective irradiance and radiance were calculated with relative spectral effectiveness data from the American Conference for Governmental and Industrial Hygienists. Safe exposure time to avoid UVR injury to the lens and cornea was found to be 2 h without a filter, 4 h with a UVR filter, 200 a yellow filter, and 400 h with a filter combination. Safe exposure time to avoid retinal photochemical injury was found to be 3 min without a filter and with a UVR filter, 10 min with a yellow filter, and 49 min with a filter combination. The effective radiance limit for retinal thermal injury was not exceeded. The hazard due to the UVR component from the operating microscope is not critical, and operation time can be safely prolonged with the use of appropriate filters. The retinal photochemical hazard appears critical without appropriate filters, permitting only some minutes of safe exposure time. The calculated safe exposure times are for worst-case conditions and maximal light output and include a safety factor.

  13. Ultraviolet Enceladus

    NASA Image and Video Library

    2004-09-23

    Looking beyond Saturn's south pole, this was the Cassini spacecraft's view of the distant, icy moon Enceladus on July 28, 2004. The planet itself shows few obvious features at these ultraviolet wavelengths, due to scattering of light by molecules of the gases high in the atmosphere. Enceladus is 499 kilometers (310 miles) wide. The image was taken with the Cassini spacecraft narrow angle camera at a distance of 7.4 million kilometers (4.6 million miles) from Saturn through a filter sensitive to ultraviolet wavelengths of light. The image scale is 44 kilometers (27 miles) per pixel of Saturn. http://photojournal.jpl.nasa.gov/catalog/PIA06483

  14. Aqueous humour and ultraviolet radiation.

    PubMed

    Ringvold, A

    1980-01-01

    Studies on the ultraviolet ray absorption in the aqueous humour of rabbit, cat, monkey, guinea pig, and rat showed marked species differences. In the rabbit aqueous the ascorbic acid, the proteins, and some amino acids (tyrosine, phenylalanine, cystine, and tryptophane) are together responsible for the total absorption, and a very great part of it refers to the ascorbic acid content. Accordingly, species with significant amounts of ascorbic acid in the aqueous (monkey, rabbit, guinea pig) have a greater absorption capacity towards ultraviolet radiation than species (cat, rat) lacking this substance. This effect of the ascorbic acid may contribute in protecting the lens against the most biotoxic ultraviolet rays. It seems that the ascorbic acid concentration is highest in the aqueous of typical day animals and lowest in species being active in the dark, indicating a correlation between the aqueous' ascorbic acid level and the quantity of incident light on the eye. The possible significance of changed aqueous ultraviolet ray absorption in the pathogenesis of human cataract development is discussed.

  15. The South Asian cataract management study: complications, vision outcomes, and corneal endothelial cell loss in a randomized multicenter clinical trial comparing intracapsular cataract extraction with and without anterior chamber intraocular lens implantation.

    PubMed

    Snellingen, T; Shrestha, J K; Huq, F; Husain, R; Koirala, S; Rao, G N; Pokhrel, R P; Kolstad, A; Upadhyay, M P; Apple, D J; Arnesen, E; Cheng, H; Olsen, E G; Vogel, M

    2000-02-01

    To determine clinical outcomes of primary intracapsular cataract surgery with and without implantation of anterior chamber lenses. A multicenter randomized clinical trial. One thousand two hundred twenty-nine male and female patients 40-75 years of age with senile cataract. Study patients were recruited from screening eye camps and outpatient clinics. Randomization to the two treatment groups was performed after screening for predetermined inclusion and exclusion criteria. Demographics, visual acuity, intraocular pressures, and corneal endothelial cell data were recorded before surgery and at 6 weeks, 12 months, and 24 months after surgery. Monitoring of the study was secured by a standardized image documentation procedure on all patients using the IMAGEnet digital imaging system. Analysis of corneal endothelial cell images was performed with the Cell Soft software (Topcon Corporation, Japan). Visual acuity and central corneal endothelial cell loss. The patients were randomized to intraocular lens (IOL; n = 616) and no IOL (n = 613) implantation. Surgical complications were reported in 177 (14.4%) patients (IOL = 14.8%; no IOL = 14.0%). The most frequent complication observed was vitreous loss which occurred in 10.3% of eyes (IOL = 11.2%; no IOL = 9.5%). At the final examination (2 years after surgery), 88% of the operated eyes had a best corrected vision of 6/18 or better (IOL = 88.8%; no IOL = 86.6%). Analysis of corneal endothelial cell data showed a small but significantly greater cell loss 6 weeks after surgery in eyes with IOL compared with those without IOL, but no overall difference was found between the treatment groups in the long term follow-up. The findings indicate that there is a rationale for the use of anterior chamber intraocular lenses in primary intracapsular cataract surgery.

  16. Predictive factors for photic phenomena after refractive, rotationally asymmetric, multifocal intraocular lens implantation

    PubMed Central

    Tchah, Hungwon; Nam, Kiyeun; Yoo, Aeri

    2017-01-01

    AIM To investigate the independent factors associated with photic phenomena in patients implanted with refractive, rotationally asymmetric, multifocal intraocular lenses (MIOLs). METHODS Thirty-four eyes of 34 patients who underwent unilateral cataract surgery, followed by implantation of rotationally asymmetric MIOLs were included. Distance and near visual acuity outcomes, intraocular aberrations, preferred reading distances, preoperative and postoperative refractive errors, mesopic and photopic pupil diameters, and the mesopic and photopic kappa angles were assessed. Patients were also administered a satisfaction survey. Photic phenomena were graded by questionnaire. Independent-related factors were identified by correlation and bivariate logistic regression analyses. RESULTS The distance from the photopic to the mesopic pupil center (pupil center shift) was significantly associated with glare/halo symptoms [odds ratio (OR)=2.065, 95% confidence interval (CI)=0.916-4.679, P=0.006] and night vision problems (OR=1.832, 95% CI=0.721-2.158, P=0.007). The preoperative photopic angle kappa was significantly associated with glare/halo symptoms (OR=2.155, 95% CI=1.065-4.362, P=0.041). The photopic angle kappa was also significantly associated with glare/halo symptoms (OR=2.155, 95% CI=1.065-4.362, P=0.041) and with night vision problems (OR=1.832, 95% CI=0.721-2.158, P=0.007) in patients implanted with rotationally asymmetric MIOLs. CONCLUSION A large pupil center shift and misalignment between the visual and pupillary axis (angle kappa) may play a role in the occurrence of photic phenomena after implantation of rotationally asymmetric MIOLs. PMID:28251083

  17. Intraocular pressure variation following retrobulbar anaesthesia among the different sex, age and ethnic groups in Malaysia.

    PubMed

    Lee, F N; Kong, V Y; Lee, G P; Ho, K H; Choon, S C; Hoh, H B

    1999-12-01

    A total of 114 patients (48 Chinese, 34 Malay and 32 Indian) undergoing extracapsular cataract extraction (ECCE) with intraocular lens implantation, were enrolled. All were given 3 ml of local anaesthetic (combination of equal amounts of lignocaine 2% and bupivacaine 0.5%) using retrobulbar technique. Intraocular pressure (IOP) was measured at different time intervals; before, immediately after and 5 minutes after injection with Honan balloon compression. Mean IOP increased by 5.0 mmHg immediately after injection (p < 0.001) and reduced to baseline level after 5 minutes of external compression. Although there were no statistical difference in terms of IOP variation between sex and age groups, Chinese patients demonstrated the highest IOP rise following retrobulbar anaesthesia. This is the first study to demonstrate the influence of race in the IOP response with Chinese subjects having the highest IOP rise.

  18. Electron microscopic examination of the anterior lens capsule in a case of Alport's syndrome.

    PubMed

    Citirik, Mehmet; Batman, Cosar; Men, Gamze; Tuncel, Murvet; Zilelioglu, Orhan

    2007-09-01

    To report a case of Alport's syndrome and to present electronmicroscopic examination findings of the anterior lens capsule of this patient. A 21-year-old man was referred for low visual acuity and retinal pigment epithelial changes in the left eye. The patient and his relatives underwent detailed ophthalmological examination, including electrophysiological testing. The patient also underwent electronmicroscopic examination of the anterior lens capsule. His visual acuity was 6/18 OD and 6/15 OS. Anterior lenticonus and subcapsular opacities were observed in the left eye. Cataract extraction by phacoemulsification with intraocular lens implantation was performed for his poor visual performance. During the capsulorhexis, the remarkably thin and fragile anterior capsule was noted and removed. Ultrastructural analysis of the anterior lens capsule showed a thinner central zone compared with the periphery. The course of Alport's syndrome can be ameliorated by early diagnosis. Therefore, the ophthalmological examination of a patient with anterior lenticonus must be combined with a detailed medical evaluation. Ultrastructural analysis of the lens capsule can support the diagnosis of Alport's syndrome.

  19. Clinical and optical intraocular performance of rotationally asymmetric multifocal IOL plate-haptic design versus C-loop haptic design.

    PubMed

    Alió, Jorge L; Plaza-Puche, Ana B; Javaloy, Jaime; Ayala, María José; Vega-Estrada, Alfredo

    2013-04-01

    To compare the visual and intraocular optical quality outcomes with different designs of the refractive rotationally asymmetric multifocal intraocular lens (MFIOL) (Lentis Mplus; Oculentis GmbH, Berlin, Germany) with or without capsular tension ring (CTR) implantation. One hundred thirty-five consecutive eyes of 78 patients with cataract (ages 36 to 82 years) were divided into three groups: 43 eyes implanted with the C-Loop haptic design without CTR (C-Loop haptic only group); 47 eyes implanted with the C-Loop haptic design with CTR (C-Loop haptic with CTR group); and 45 eyes implanted with the plate-haptic design (plate-haptic group). Visual acuity, contrast sensitivity, defocus curve, and ocular and intraocular optical quality were evaluated at 3 months postoperatively. Significant differences in the postoperative sphere were found (P = .01), with a more myopic postoperative refraction for the C-Loop haptic only group. No significant differences were detected in photopic and scotopic contrast sensitivity among groups (P ⩾ .05). Significantly better visual acuities were present in the C-Loop haptic with CTR group for the defocus levels of -2.0, -1.5, -1.0, and -0.50 D (P ⩽.03). Statistically significant differences among groups were found in total intraocular root mean square (RMS), high-order intraocular RMS, and intraocular coma-like RMS aberrations (P ⩽.04), with lower values from the plate-haptic group. The plate-haptic design and the C-Loop haptic design with CTR implantation both allow good visual rehabilitation. However, better refractive predictability and intraocular optical quality was obtained with the plate-haptic design without CTR implantation. The plate-haptic design seems to be a better design to support rotational asymmetric MFIOL optics. Copyright 2013, SLACK Incorporated.

  20. Causes of Phakic Implantable Collamer Lens Explantation/Exchange at King Khaled Eye Specialist Hospital

    PubMed Central

    AlSabaani, Nasser A.; Behrens, Ashley; Jastanieah, Sabah; Al Malki, Salem; Al Jindan, Mohanna; Al Motowa, Saeed

    2016-01-01

    PURPOSE: The purpose of this study is to evaluate the causes of phakic implantable collamer lens (ICL) explantation/exchange at an eye hospital in Saudi Arabia. MATERIALS AND METHODS: A retrospective chart review was performed for patients who underwent ICL implantation from 2007 to March 2014 and data were collected on cases that underwent ICL explantation. RESULTS: Of the 787 ICL implants, 30 implants (3.8% [95% confidence interval 2.6%; 5.3%]) were explanted. The causes of explantation included incorrect lens size (22), cataract (4), high residual astigmatism (2), rhegmatogenous retinal detachment (1), and intolerable glare (1). Corrective measures mainly included an exchange with an appropriately sized lens (9), ICL explantation (11), with phacoemulsification and posterior chamber intraocular lens implantation (6), or replacement with an ICL of correct power (2). CONCLUSION: Incorrect ICL size was the most common cause of ICL explantation. More accurate sizing methods for ICL are required to reduce the explantation/exchange rate. PMID:27994391

  1. Reducing angiographic cystoid macular edema and blood-aqueous barrier disruption after small-incision phacoemulsification and foldable intraocular lens implantation: multicenter prospective randomized comparison of topical diclofenac 0.1% and betamethasone 0.1%.

    PubMed

    Asano, Sayaka; Miyake, Kensaku; Ota, Ichiro; Sugita, Gentaro; Kimura, Wataru; Sakka, Yuji; Yabe, Nobuyuki

    2008-01-01

    To compare the effectiveness of a topical nonsteroidal drug (diclofenac 0.1%) and a topical steroidal drug (betamethasone 0.1%) in preventing cystoid macular edema (CME) and blood-aqueous barrier (BAB) disruption after small-incision cataract surgery and foldable intraocular lens (IOL) implantation. Shohzankai Medical Foundation Miyake Eye Hospital, Tokyo, Japan. This multicenter interventional double-masked randomized study comprised 142 patients having phacoemulsification and foldable IOL implantation. Seventy-one patients were randomized to receive diclofenac eyedrops and 71, betamethasone eyedrops for 8 weeks postoperatively. The incidence and severity of CME were evaluated by fluorescein angiography. Blood-aqueous barrier disruption was determined by laser flare-cell photometry. Of the patients, 63 were men and 79 were women. Five weeks after surgery, the incidence of fluorescein angiographic CME was lower in the diclofenac group (18.8%) than in the betamethasone group (58.0%) (P<.001). At 1 and 2 weeks, the amount of anterior chamber flare was statistically significantly less in the diclofenac group than in the betamethasone group (P<.05). At 8 weeks, intraocular pressure was statistically significantly higher in the betamethasone group (P = .0003). Diclofenac was more effective than betamethasone in preventing angiographic CME and BAB disruption after small-incision cataract surgery. Thus, nonsteroidal antiinflammatory agents should be considered for routine treatment of eyes having cataract surgery.

  2. Postoperative Refractive Errors Following Pediatric Cataract Extraction with Intraocular Lens Implantation.

    PubMed

    Indaram, Maanasa; VanderVeen, Deborah K

    2018-01-01

    Advances in surgical techniques allow implantation of intraocular lenses (IOL) with cataract extraction, even in young children. However, there are several challenges unique to the pediatric population that result in greater degrees of postoperative refractive error compared to adults. Literature review of the techniques and outcomes of pediatric cataract surgery with IOL implantation. Pediatric cataract surgery is associated with several sources of postoperative refractive error. These include planned refractive error based on age or fellow eye status, loss of accommodation, and unexpected refractive errors due to inaccuracies in biometry technique, use of IOL power formulas based on adult normative values, and late refractive changes due to unpredictable eye growth. Several factors can preclude the achievement of optimal refractive status following pediatric cataract extraction with IOL implantation. There is a need for new technology to reduce postoperative refractive surprises and address refractive adjustment in a growing eye.

  3. Development of a human eye model incorporated with intraocular scattering for visual performance assessment

    NASA Astrophysics Data System (ADS)

    Chen, Yi-Chun; Jiang, Chong-Jhih; Yang, Tsung-Hsun; Sun, Ching-Cherng

    2012-07-01

    A biometry-based human eye model was developed by using the empirical anatomic and optical data of ocular parameters. The gradient refractive index of the crystalline lens was modeled by concentric conicoid isoindical surfaces and was adaptive to accommodation and age. The chromatic dispersion of ocular media was described by Cauchy equations. The intraocular scattering model was composed of volumetric Mie scattering in the cornea and the crystalline lens, and a diffusive-surface model at the retina fundus. The retina was regarded as a Lambertian surface and was assigned its corresponding reflectance at each wavelength. The optical performance of the eye model was evaluated in CodeV and ASAP and presented by the modulation transfer functions at single and multiple wavelengths. The chromatic optical powers obtained from this model resembled that of the average physiological eyes. The scattering property was assessed by means of glare veiling luminance and compared with the CIE general disability glare equation. By replacing the transparent lens with a cataractous lens, the disability glare curve of cataracts was generated to compare with the normal disability glare curve. This model has high potential for investigating visual performance in ordinary lighting and display conditions and under the influence of glare sources.

  4. The Effects of Phacoemulsification and Intraocular Lens Implantation on Anatomical and Functional Parameters in Patients with Primary Angle Closure: A Prospective Study. (An American Ophthalmological Society Thesis).

    PubMed

    Traverso, Carlo Enrico; Cutolo, Carlo Alberto

    2017-08-01

    To investigate the clinical, anatomical, and patient-reported outcomes of phacoemulsification (PE) with intraocular lens implantation performed to treat primary angle closure (PAC) and primary angle-closure glaucoma (PACG). Patients were evaluated at baseline and at 6 months after PE. The examination included visual acuity, intraocular pressure (IOP), visual field, optic nerve head, endothelial cell count (ECC), aqueous depth, and ocular biometric parameters. Patient-reported visual function and health status were assessed. Coprimary outcome measures were IOP changes, angle widening, and patient-reported visual function; secondary outcome measures were visual acuity changes, use of IOP-lowering medications, and complications. Univariate and multivariate analyses were performed to determine the predictors of IOP change. Thirty-nine cases were identified, and postoperative data were analyzed for 59 eyes, 39 with PACG and 20 with PAC. Globally, PE resulted in a mean reduction in IOP of -6.33 mm Hg (95% CI, -8.64 to -4.01, P <.001). Aqueous depth and angle measurements improved ( P <.01), whereas ECC significantly decreased ( P <.001). Both corrected and uncorrected visual acuity improved ( P <.01). The EQ visual analog scale did not change ( P =.16), but VFQ-25 improved ( P <.01). The IOP-lowering effect of PE was greater in the PACG compared to the PAC group ( P =.04). In both groups, preoperative IOP was the most significant predictor of IOP change ( P <.01). No sight-threatening complications were recorded. Our data support the usefulness of PE in lowering the IOP in patients with PAC and PACG. Although PE resulted in several anatomical and patient-reported visual improvements, we observe that a marked decrease in ECC should be carefully weighed before surgery.

  5. Visual outcomes after lensectomy and iris claw artisan intraocular lens implantation in patients with Marfan syndrome.

    PubMed

    Rabie, Hossein Mohammad; Malekifar, Parviz; Javadi, Mohammad Ali; Roshandel, Danial; Esfandiari, Hamed

    2017-08-01

    To review our experience with crystalline lens extraction and iris claw Artisan IOL implantation in patients with lens subluxation secondary to Marfan syndrome. A retrospective analysis of 12 eyes of 9 patients with lens subluxation due to Marfan syndrome who underwent crystalline lens removal and Artisan IOL (Ophtec, Groningen, Netherlands) implantation. A questionnaire of pre- and post-operative data, including demographics, pre- and postoperative comorbidities and complications was completed. Patients were evaluated for visual outcome and occurrence of complications. Uncorrected visual acuity (UCVA), best-corrected visual acuity (BCVA), and spherical equivalents (SE) were compared before and after lens extraction and IOL insertion. The mean age of the participants was 30.03 ± 15.02 years, and mean post-operative follow-up time was 44.5 ± 16.4 months. Mean BCVA also showed a significant improvement from 0.5 ± 0.3 at the baseline to 0.2 ± 0.2 post-operatively (P = 0.006). SE changed significantly from -11.38 ± 1.99 preoperatively to -0.45 ± 1.65 post-operatively (P = 0.003). All eyes had the IOL implanted at desired position. Post-operative complications were retinal detachment in one case and IOL dislocation in another patient. No other complication such as ocular hypertension, angle abnormalities, clinical cystoids macular edema, and corneal decompensation was observed during the follow-up period. Artisan IOL implantation after lens extraction appears to be an attractive alternative for optical correction in cases of Marfan syndrome with ectopia lentis. It confers a significant improvement in visual acuity with reasonable risk profile.

  6. Light scatter on the surface of AcrySof intraocular lenses: part I. Analysis of lenses retrieved from pseudophakic postmortem human eyes.

    PubMed

    Yaguchi, Shigeo; Nishihara, Hitoshi; Kambhiranond, Waraporn; Stanley, Daniel; Apple, David J

    2008-01-01

    To investigate the cause of light scatter measured on the surface of AcrySof intraocular lenses (Alcon Laboratories, Inc., Fort Worth, TX) retrieved from pseudophakic postmortem human eyes. Ten intraocular lenses (Alcon AcrySofModel MA60BM) were retrieved postmortem and analyzed for light scatter before and after removal of surface-bound biofilms. Six of the 10 lenses exhibited light scatter that was clearly above baseline levels. In these 6 lenses, both peak and average pixel density were reduced by approximately 80% after surface cleaning. The current study demonstrates that a coating deposited in vivo on the lens surface is responsible for the light scatter observed when incident light is applied.

  7. Comparative analysis of the visual and refractive outcomes of an aspheric diffractive intraocular lens with and without toricity.

    PubMed

    Frieling-Reuss, Elisabeth H

    2013-10-01

    To analyze and compare the postoperative visual and refractive outcomes and patients' visual satisfaction after implantation of an aspheric or an aspheric toric multifocal diffractive intraocular lens (IOL) in eyes with equivalent biometric characteristics. Private clinic, Munich, Germany. Comparative case series. Patients having cataract surgery were assigned to 1 of 2 groups: aspheric, which had AT Lisa 809M IOL implantation, and aspheric toric, which had AT Lisa 909M IOL implantation (corneal toricity ≥0.75 diopter [D]). Visual and refractive postoperative outcomes were evaluated, as was the patient's ability to perform daily tasks related to vision and the incidence of photic phenomena. The aspheric group comprised 77 eyes (42 patients) and the aspheric toric group, 26 eyes (17 patients). A significant improvement in corrected distance and near visual acuity was observed postoperatively in both groups, as was a significant reduction in the astigmatic component J0 (P<.01). The aspheric toric group had significantly better uncorrected intermediate visual acuity (P=.01). In both groups, the postoperative astigmatic power vectors and spherical equivalent were within ±0.50 D in 100% of eyes and in more than 88% of eyes, respectively. No statistically significant differences were found in any subjective patient questionnaire item. There was no difference in the incidence of photic phenomena between the groups (P≥0.16). The addition of a toric surface to the aspheric diffractive multifocal platform resulted in a comparable visual performance and ability to perform visual tasks. The author has no financial or proprietary interest in any material or method mentioned. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  8. Intraocular pressure reduction and regulation system

    NASA Technical Reports Server (NTRS)

    Baehr, E. F.; Burnett, J. E.; Felder, S. F.; Mcgannon, W. J.

    1979-01-01

    An intraocular pressure reduction and regulation system is described and data are presented covering performance in: (1) reducing intraocular pressure to a preselected value, (2) maintaining a set minimum intraocular pressure, and (3) reducing the dynamic increases in intraocular pressure resulting from external loads applied to the eye.

  9. Changes in astigmatism and corneal higher-order aberrations after phacoemulsification with toric intraocular lens implantation for mild keratoconus with cataract.

    PubMed

    Kamiya, Kazutaka; Shimizu, Kimiya; Miyake, Toshiyuki

    2016-07-01

    To assess the changes in astigmatism and higher-order aberrations (HOAs) after toric intraocular lens (IOL) implantation for mild non-progressive keratoconus with cataract. We prospectively examined 19 eyes of 19 consecutive keratoconic patients (mean age ± standard deviation, 63.1 ± 9.1 years) who underwent phacoemulsification with toric IOL implantation. We determined uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), refractive astigmatism, corneal astigmatism, corneal HOAs and astigmatic axis rotation both preoperatively and 3 months postoperatively. Logarithm of the minimal angle of resolution (logMAR) UDVA was significantly improved from 1.14 ± 0.50 preoperatively to 0.46 ± 0.33 postoperatively (Wilcoxon signed-rank test, p < 0.001). LogMAR CDVA was also significantly improved from 0.27 ± 0.45 preoperatively to -0.01 ± 0.09 postoperatively (p < 0.001). In 5 of 6 eyes in which the target refraction was emmetropia, postoperative UDVA was better than 20/32. The achieved spherical equivalent correction was within ±0.5 diopters (D) of the targeted correction in 13 (68 %) eyes and 1.0 in 18 (95 %) eyes. The refractive astigmatism was significantly decreased from -1.92 ± 1.73 D preoperatively to -0.70 ± 0.60 D postoperatively (p = 0.006). The corneal astigmatism changed from 2.89 ± 1.30 D preoperatively to 2.98 ± 1.09 D postoperatively (p = 0.492), which was not statistically significant. The corneal HOAs for a 4-mm pupil was changed from 0.47 ± 0.23 µm preoperatively to 0.52 ± 0.26 µm postoperatively (p = 0.211), which was not statistically significant. According to our experience, toric IOL implantation for mild keratoconic patients having rigid gas-permeable lens intolerance appears to be effective for reducing refractive astigmatism without a significant induction of corneal HOAs.

  10. Far Ultraviolet Refractive Index of Optical Materials for Solar Blind Channel (SBC) Filters for HST Advanced Camera for Surveys

    NASA Technical Reports Server (NTRS)

    Leviton, Douglas B.; Madison, Timothy J.; Petrone, Peter

    1998-01-01

    Refractive index measurements using the minimum deviation method have been carried out for prisms of a variety of far ultraviolet optical materials used in the manufacture of Solar Blind Channel (SBC) filters for the HST Advanced Camera for Surveys (ACS). Some of the materials measured are gaining popularity in a variety of high technology applications including high power excimer lasers and advanced microlithography optics operating in a wavelength region where high quality knowledge of optical material properties is sparse. Our measurements are of unusually high accuracy and precision for this wavelength region owing to advanced instrumentation in the large vacuum chamber of the Diffraction Grating Evaluation Facility (DGEF) at Goddard Space Flight Center (GSFC). Index values for CaF2, BaF2, LiF, and far ultraviolet grades of synthetic sapphire and synthetic fused silica are reported and compared with values from the literature.

  11. [Impact of an Aspherical Aberration Correcting Monofocal Intraocular Lens on Patient Satisfaction for Daily Life Activities: The Heidelberg Daily Task Evaluation (DATE) Questionnaire].

    PubMed

    Kretz, F T A; Son, H; Liebing, S; Tandogan, T; Auffarth, G U

    2015-08-01

    A clinical evaluation of the functional results and its impact on daily activities of an aspherical, aberration correcting intraocular lens (IOL) was undertaken. Twenty-one patients aged from 50 to 83 years underwent cataract surgery with implantation of the aspheric IOL (Tecnis ZCB00, Abbott Medical Optics). They were evaluated 2 to 4 months after surgery for their subjective satisfaction of vision quality and its impact on performance of daily activities as well as functional results and refractive outcome. Patients were asked to fill out a questionnaire - the Heidelberg DATE (DAily Tasks Evaluation) questionnaire. Significant changes from pre- to postoperative results were found in refraction (p ≤ 0.03), with a mean prediction error of + 0.21 ± 0.43 D. UDVA and CDVA improved significantly (p < 0.01), with a postoperative CDVA of 0.0 logMAR or better in 97.1 % of eyes. All patients would recommend the procedure to a relative or a friend and 93.8 % of patients reported to be satisfied with the outcome. The implantation of the aspheric IOL Tecnis ZCB00 after cataract surgery allows the restoration of visual function, providing an optimised optical quality and a high level of patient satisfaction. Georg Thieme Verlag KG Stuttgart · New York.

  12. Simple technique to measure toric intraocular lens alignment and stability using a smartphone.

    PubMed

    Teichman, Joshua C; Baig, Kashif; Ahmed, Iqbal Ike K

    2014-12-01

    Toric intraocular lenses (IOLs) are commonly implanted to correct corneal astigmatism at the time of cataract surgery. Their use requires preoperative calculation of the axis of implantation and postoperative measurement to determine whether the IOL has been implanted with the proper orientation. Moreover, toric IOL alignment stability over time is important for the patient and for the longitudinal evaluation of toric IOLs. We present a simple, inexpensive, and precise method to measure the toric IOL axis using a camera-enabled cellular phone (iPhone 5S) and computer software (ImageJ). Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  13. Predicting crystalline lens fall caused by accommodation from changes in wavefront error

    PubMed Central

    He, Lin; Applegate, Raymond A.

    2011-01-01

    PURPOSE To illustrate and develop a method for estimating crystalline lens decentration as a function of accommodative response using changes in wavefront error and show the method and limitations using previously published data (2004) from 2 iridectomized monkey eyes so that clinicians understand how spherical aberration can induce coma, in particular in intraocular lens surgery. SETTINGS College of Optometry, University of Houston, Houston, USA. DESIGN Evaluation of diagnostic test or technology. METHODS Lens decentration was estimated by displacing downward the wavefront error of the lens with respect to the limiting aperture (7.0 mm) and ocular first surface wavefront error for each accommodative response (0.00 to 11.00 diopters) until measured values of vertical coma matched previously published experimental data (2007). Lens decentration was also calculated using an approximation formula that only included spherical aberration and vertical coma. RESULTS The change in calculated vertical coma was consistent with downward lens decentration. Calculated downward lens decentration peaked at approximately 0.48 mm of vertical decentration in the right eye and approximately 0.31 mm of decentration in the left eye using all Zernike modes through the 7th radial order. Calculated lens decentration using only coma and spherical aberration formulas was peaked at approximately 0.45 mm in the right eye and approximately 0.23 mm in the left eye. CONCLUSIONS Lens fall as a function of accommodation was quantified noninvasively using changes in vertical coma driven principally by the accommodation-induced changes in spherical aberration. The newly developed method was valid for a large pupil only. PMID:21700108

  14. In-the-Bag Intraocular Lens Placement via Secondary Capsulorhexis with Radiofrequency Diathermy in Pediatric Aphakic Eyes

    PubMed Central

    Wang, Chunxiao; Zhang, Xinyu; Tang, Xiangchen; Liu, Jianping; Congdon, Nathan; Chen, Jingjing; Lin, Zhuoling; Liu, Yizhi

    2013-01-01

    Pediatric ophthalmologists increasingly recognize that the ideal site for intraocular lens (IOL) implantation is in the bag for aphakic eyes, but it is always very difficult via conventional technique. We conducted a prospective case series study to investigate the success rate and clinical outcomes of capsular bag reestablishment and in-the-bag IOL implantation via secondary capsulorhexis with radiofrequency diathermy (RFD) in pediatric aphakic eyes, in which twenty-two consecutive aphakic pediatric patients (43 aphakic eyes) enrolled in the Childhood Cataract Program of the Chinese Ministry of Health were included. The included children underwent either our novel technique for secondary IOL implantation (with RFD) or the conventional technique (with a bent needle or forceps), depending on the type of preoperative proliferative capsular bag present. In total, secondary capsulorhexis with RFD was successfully applied in 32 eyes (32/43, 74.4%, age 5.6±2.3 years), of which capsular bag reestablishment and in-the-bag IOL implantation were both achieved in 30 eyes (30/43, 70.0%), but in the remaining 2 eyes (2/32, 6.2%) the IOLs were implanted in the sulcus with a capsular bag that was too small. Secondary capsulorhexis with conventional technique was applied in the other 11 eyes (11/43, 25.6%, age 6.9±2.3 years), of which capsular bag reestablishment and in-the-bag IOL implantation were both achieved only in 3 eyes(3/43, 7.0%), and the IOLs were implanted in the sulcus in the remaining 8 eyes. A doughnut-like proliferative capsular bag with an extensive Soemmering ring (32/43, 74.4%) was the main success factor for secondary capsulorhexis with RFD, and a sufficient capsular bag size (33/43, 76.7%) was an additional factor in successful in-the-bag IOL implantation. In conclusion, RFD secondary capsulorhexis technique has 70% success rate in the capsular bag reestablishment and in-the-bag IOL implantation in pediatric aphakic eyes, particularly effective in cases with

  15. Intraocular (Eye) Melanoma—Health Professional Version

    Cancer.gov

    Intraocular (uveal) melanoma of the uveal tract (iris, ciliary body, and choroid), though rare, is the most common primary intraocular malignancy in adults. Find evidence-based information on intraocular melanoma treatment.

  16. Comparison of decentration and tilt between one piece and three piece polymethyl methacrylate intraocular lenses

    PubMed Central

    Hayashi, K.; Hayashi, H.; Nakao, F.; Hayashi, F.

    1998-01-01

    BACKGROUND—The extent of the decentration and tilt was prospectively compared between one piece polymethyl methacrylate (PMMA) and three piece PMMA intraocular lenses (IOLs) which were implanted in the capsular bag after performing continuous curvilinear capsulorhexis.
METHODS—91 patients underwent a one piece PMMA IOL implantation in one eye as well as the implantation of the three piece PMMA IOL with polyvinylidene fluoride loops in the opposite eye. The length of the lens decentration and the angle of the tilt were quantitated using the anterior eye segment analysis system (EAS-1000) at 1 week as well as 1, 3, and 6 months postoperatively.
RESULTS—The mean length of the decentration in the one piece IOL was smaller than that in the three piece IOL at 1 week (p=0.0092), 1 month (p=0.0044), 3 months (p=0.0069), and 6 months (p=0.0010) postoperatively. However, no significant difference was found in the degree of the tilt between the two types of IOLs throughout the observation periods.
CONCLUSION—These results clarified that the one piece PMMA IOL with rigid PMMA haptics implanted in the capsular bag provides a better centration than the three piece PMMA IOL with flexible haptics, whereas the tilt was the same between the two types of IOLs.

 Keywords: intraocular lens; decentration; tilt; continuous curvilinear capsulorhexis PMID:9640193

  17. Foreign body giant cells selectively covering haptics of intraocular lens implants: indicators of poor toleration?

    PubMed

    Wolter, J R

    1983-10-01

    A Sputnik lens implant removed after five years because of bullous keratopathy exhibits a dense covering of its Supramid anterior staves with large foreign body giant cells, while its Prolene loops and Polymethylmethacrylate optics have attracted only few of these cell units. The glass-membrane-like component of the reactive membrane also shows significant differences on the different parts of this implant. The use of observation of the components of reactive membranes on lens implants as indicators of toleration in the eye is suggested.

  18. STEREO's Extreme UltraViolet Imager (EUVI)

    NASA Technical Reports Server (NTRS)

    2007-01-01

    At a pixel resolution of 2048x2048, the STEREO EUVI instrument provides views of the Sun in ultraviolet light that rivals the full-disk views of SOHO/EIT. This image is through the 171 Angstrom (ultraviolet) filter which is characteristic of iron ions (missing eight and nine electrons) at 1 million degrees. There is a short data gap in the latter half of the movie that creates a freeze and then jump in the data view. This is a movie of the Sun in 171 Angstrom ultraviolet light. The time frame is late January, 2007

  19. An evaluation of novel vital dyes for intraocular surgery.

    PubMed

    Haritoglou, Christos; Yu, Alice; Freyer, Wolfgang; Priglinger, Siegfried G; Alge, Claudia; Eibl, Kirsten; May, Christian A; Welge-Luessen, Ulrich; Kampik, Anselm

    2005-09-01

    To evaluate systematically the staining characteristics and safety of potential new dyes for intraocular surgery. Six dyes were included in the investigation: light green SF (LGSF) yellowish, E68, bromophenol blue (BPB), Chicago blue (CB), rhodamine 6G, rhodulinblau-basic 3 (RDB-B3). All dyes were dissolved and diluted in a balanced saline saline solution. The light-absorbing properties of each dye were measured at a concentration of 0.05% between 200 and 1000 nm. Staining characteristics were examined by staining lens capsule tissue and epiretinal membranes (ERMs), removed intraoperatively, with dye concentrations of 1.0%, 0.5%, 0.2%, and 0.05%. Enucleated porcine eyes (postmortem time, 9 hours) were also stained. Dye-related toxicity was evaluated by a colorimetric test (MTT) measuring the inhibition of retinal pigment epithelium (RPE) cell proliferation (ARPE-19 and primary human RPE cells, passages 3-6). Cell viability was also quantified based on a two-color fluorescence cell-viability assay. Dyes were investigated in concentrations of 0.2% and 0.02%. All dyes investigated in this study stained human lens capsules, removed intraoperatively; ERMs, peeled during macular pucker surgery; and enucleated porcine eyes, depending on the concentration applied. The long-wavelength absorption maximum of the dyes was within the range of 527 to 655 nm at concentrations of 0.05%. Rhodamine G6 and RDB-B3 showed adverse effects on ARPE-19 cell proliferation at a concentration of 0.2% and were excluded from further investigation in primary RPE cells. The remaining four dyes showed no toxic effect on ARPE-19 and primary RPE cell proliferation at concentrations of 0.2% and 0.02%. Cell viability was affected by LGSF yellowish (0.2%) and CB (0.2% and 0.02%). Two dyes (E68 and BPB) showed no relevant toxicity in vitro. The systematic evaluation of dyes for intraocular use seems mandatory. In this study four dyes were identified with effective staining characteristics, with two of

  20. Surface cytologic features on intraocular lenses: can increased biocompatibility have disadvantages?

    PubMed

    Hollick, E J; Spalton, D J; Ursell, P G

    1999-07-01

    To compare the anterior surface cytologic features and effect on blood-aqueous barrier of polymethyl methacrylate, silicone, and hydrogel intraocular lens (IOL) implants to give an indication of their biocompatibility. This prospective study was performed at an English-teaching hospital. Ninety eyes were randomized to receive a polymethyl methacrylate, silicone, or hydrogel implant. A standardized surgical protocol was performed by a single surgeon using phacoemulsification. Patients were seen at intervals for 1 year. Measurements of visual acuity, contrast sensitivity, and anterior chamber laser flare and cells were obtained; and an assessment of lens cytologic features using specular microscopy of the anterior IOL surface was performed. Visual acuity and contrast sensitivity were not significantly different among the 3 groups. Hydrogel IOLs were associated with fewer inflammatory cells on their surface than polymethyl methacrylate and silicone IOLs (P<.001), but with significantly more lens epithelial cells (LECs) (P<.001). Patients with hydrogel implants without LECs had greater blood-aqueous barrier breakdown than those with LECs. The hydrogel IOLs were associated with a reduced inflammatory cell reaction but had many more LECs on their anterior surface. Those IOLs associated with increased blood-aqueous barrier damage did not develop LECs. If an IOL is too biocompatible, then it may incite the growth of LECs over its surface, which could have disadvantages.

  1. Optical effects of exposing intact human lenses to ultraviolet radiation and visible light.

    PubMed

    Kessel, Line; Eskildsen, Lars; Lundeman, Jesper Holm; Jensen, Ole Bjarlin; Larsen, Michael

    2011-12-30

    The human lens is continuously exposed to high levels of light. Ultraviolet radiation is believed to play a causative role in the development of cataract. In vivo, however, the lens is mainly exposed to visible light and the ageing lens absorbs a great part of the short wavelength region of incoming visible light. The aim of the present study was to examine the optical effects on human lenses of short wavelength visible light and ultraviolet radiation. Naturally aged human donor lenses were irradiated with UVA (355 nm), violet (400 and 405 nm) and green (532 nm) lasers. The effect of irradiation was evaluated qualitatively by photography and quantitatively by measuring the direct transmission before and after irradiation. Furthermore, the effect of pulsed and continuous laser systems was compared as was the effect of short, intermediate and prolonged exposures. Irradiation with high intensity lasers caused scattering lesions in the human lenses. These effects were more likely to be seen when using pulsed lasers because of the high pulse intensity. Prolonged irradiation with UVA led to photodarkening whereas no detrimental effects were observed after irradiation with visible light. Irradiation with visible light does not seem to be harmful to the human lens except if the lens is exposed to laser irradiances that are high enough to warrant thermal protein denaturation that is more readily seen using pulsed laser systems.

  2. Design, assembly, and testing of a high-resolution relay lens used for holography with operation at both doubled and tripled Nd:YAG laser wavelengths

    NASA Astrophysics Data System (ADS)

    Malone, Robert M.; Capelle, Gene A.; Cox, Brian C.; Frogget, Brent C.; Grover, Mike; Kaufman, Morris I.; Pazuchanics, Peter; Sorenson, Danny S.; Stevens, Gerald D.; Tibbitts, Aric; Turley, William D.

    2009-08-01

    The design and assembly of a nine-element lens that achieves >2000 lp/mm resolution at a 355-nm wavelength (ultraviolet) has been completed. By adding a doublet to this lens system, operation at a 532-nm wavelength (green) with >1100 lp/mm resolution is achieved. This lens is used with high-power laser light to record holograms of fast-moving ejecta particles from a shocked metal surface located inside a test package. Part of the lens and the entire test package are under vacuum with a 1-cm air gap separation. Holograms have been recorded with both doubled and tripled Nd:YAG laser light. The UV operation is very sensitive to the package window's tilt. If this window is tilted by more than 0.1 degrees, the green operation performs with better resolution than that of the UV operation. The setup and alignment are performed with green light, but the dynamic recording can be done with either UV light or green light. A resolution plate can be temporarily placed inside the test package so that a television microscope located beyond the hologram position can archive images of resolution patterns that prove that the calibration wires, interference filter, holographic plate, and relay lenses are in their correct positions. Part of this lens is under vacuum, at the point where the laser illumination passes through a focus. Alignment and tolerancing of this high-resolution lens are presented. Resolution variation across the 12-mm field of view and throughout the 5-mm depth of field is discussed for both wavelengths.

  3. Visual simulation through an aspheric aberration-correcting intraocular lens in subjects with different corneal profiles using adaptive optics.

    PubMed

    Ruiz-Alcocer, Javier; Madrid-Costa, David; García-Lázaro, Santiago; Albarrán-Diego, César; Ferrer-Blasco, Teresa

    2013-07-01

    The aim of this study was to analyse the visual quality of the AcrySof IQ SN60WF(®) intraocular lens (IOL) when combined with different corneal profiles. Ten eyes of 10 participants with no prior history of refractive or cataract surgery were evaluated. An adaptive optics visual simulator was used to simulate the wavefront aberration pattern of an aspheric aberration-correcting IOL (AcrySof IQ SN60WF(®)). Normal corneas (group A), low and high myopic corneal ablations (groups B and C, respectively) and low and high hyperopic corneal ablations (groups D and E, respectively) were also simulated. Monocular distance visual acuities at 100, 50 and 10 per cent of contrast were measured. At 100, 50 and 10 per cent contrast, no differences were found between groups A and B (p > 0.06 for all contrasts). Group A obtained better values than groups C, D and E for all contrasts (p = 0.031, p = 0.038, p = 0.032 at 100, 50 and 10 per cent of contrast, respectively). At the same time, group B obtained better values than groups C, D and E (p = 0.041, p = 0.042, p = 0.036 at 100, 50 and 10 per cent of contrast, respectively). Within the five groups, the worst results were always obtained for group E (p = 0.017, p = 0.021 and p = 0.025 at 100, 50 and 10 per cent of contrast, respectively). The results suggest that the aspheric aberration-correcting IOL studied provides comparable results, when it is combined with normal corneas and with corneas with simulated low myopic ablations. When negative amounts of residual spherical aberration after cataract surgery are expected to be achieved, IOLs with more positive spherical aberration should be considered. © 2013 The Authors. Clinical and Experimental Optometry © 2013 Optometrists Association Australia.

  4. Clinical Evaluation of Reading Performance Using the Salzburg Reading Desk With a Refractive Rotational Asymmetric Multifocal Intraocular Lens.

    PubMed

    Linz, Katharina; Attia, Mary S A; Khoramnia, Ramin; Tandogan, Tamer; Kretz, Florian T; Auffarth, Gerd Uwe

    2016-08-01

    To evaluate functional results and reading performance using the Salzburg Reading Desk after implantation of a sector-shaped near-embedded, rotational asymmetrical multifocal intraocular lens (IOL) and a multifocal toric IOL with a +3.00 diopter (D) near addition. In a prospective study, the LentisMplus and Mplus toric IOLs (Oculentis GmbH, Berlin, Germany) were implanted in 34 eyes of 18 patients at the University Eye Hospital of Heidelberg. Uncorrected and corrected distance visual acuity (UDVA, CDVA) and uncorrected and corrected near visual acuity (UNVA, CNVA) were evaluated using standardized visual acuity charts (ETDRS). The Salzburg Reading Desk was used to analyze unilateral and bilateral uncorrected and corrected reading acuity, reading distance, reading speed, and the smallest log-scaled print size that could be read effectively at a set (40 cm/80 cm) and subjective chosen near and intermediate distance. Postoperatively, the median UDVA was 0.08 logMAR (20/25 Snellen) and the median CDVA was 0.01 logMAR (20/20 Snellen). The median UNVA was 0.12 logMAR (20/25 Snellen) and the median CNVA was 0.03 logMAR (20/20 Snellen). The median uncorrected reading acuity measured with the Salzburg Reading Desk for near distance at 40 cm was 0.18 logMAR (20/32 Snellen). The subjectively preferred near distance was 39 cm and revealed similar visual acuity results. The best reading acuity for intermediate distance with a median of 0.22 logMAR (20/32 Snellen) was achieved at a median distance of 62 cm. Reading performance of the multifocal IOL corresponded for near standardized and individual distance, whereas reading function was better at the patient's preferred intermediate distance. [J Refract Surg. 2016;32(8):526-532.]. Copyright 2016, SLACK Incorporated.

  5. Biometry and intraocular lens power calculation results with a new optical biometry device: comparison with the gold standard.

    PubMed

    Kaswin, Godefroy; Rousseau, Antoine; Mgarrech, Mohamed; Barreau, Emmanuel; Labetoulle, Marc

    2014-04-01

    To evaluate the agreement in axial length (AL), keratometry (K), anterior chamber depth (ACD) measurements; intraocular lens (IOL) power calculations; and predictability using a new partial coherence interferometry (PCI) optical biometer (AL-Scan) and a reference (gold standard) PCI optical biometer (IOLMaster 500). Service d'Ophtalmologie, Hopital Bicêtre, APHP Université, Paris, France. Evaluation of a diagnostic device. One eye of consecutive patients scheduled for cataract surgery was measured. Biometry was performed with the new biometer and the reference biometer. Comparisons were performed for AL, average K at 2.4 mm, ACD, IOL power calculations with the Haigis and SRK/T formulas, and postoperative predictability of the devices. A P value less than 0.05 was statistically significant. The study enrolled 50 patients (mean age 72.6 years±4.2 SEM). There was a good correlation between biometers for AL, K, and ACD measurements (r=0.999, r=0.933, and r=0.701, respectively) and between IOL power calculation with the Haigis formula (r=0.972) and the SRK/T formula (r=0.981). The mean absolute error (MAE) in IOL power prediction was 0.42±0.08 diopter (D) with the new biometer and 0.44±0.08 D with the reference biometer. The MAE was 0.20 D with the Haigis formula and 0.19 with the SRK/T formula (P=.36). The new PCI biometer provided valid measurements compared with the current gold standard, indicating that the new device can be used for IOL power calculations for routine cataract surgery. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  6. Twenty-four hour intraocular pressure monitoring with the SENSIMED Triggerfish contact lens: effect of body posture during sleep.

    PubMed

    Beltran-Agulló, Laura; Buys, Yvonne M; Jahan, Farzana; Shapiro, Colin M; Flanagan, John G; Cheng, Jason; Trope, Graham E

    2017-10-01

    To determine the difference in relative intraocular pressure (IOP) measured by the SENSIMED Triggerfish (TF) contact lens in flat compared with 30° head-up sleeping positions in patients with progressive primary open-angle glaucoma or normotensive glaucoma, based on recent or recurrent disc haemorrhage. Prospective, randomised, cross-over, open-label comparative study. IOP was monitored for 24 hours using TF on two separate sessions. Patients were randomly assigned to sleep flat one night and 30° head-up the other. Outputs in arbitrary units were obtained. Sleep and wake periods were defined as 22:00-6:00 and 8:00-22:00, respectively. Mean TF values during sleep and wake periods and wake-sleep and sleep-wake slopes were calculated for each session. TF output signals were compared between positions. Twelve subjects completed the study. Significant mean positive slopes were noted during the sleep period for both positions (p<0.01). No significant differences in the TF mean values were observed between positions (p=0.51). Six (54%) subjects had mean TF values significantly higher during the flat supine session, while four (36%) subjects had higher values during the head-up session. A significant increase in Goldmann IOP (p=0.001) and TF (p=0.02) measurements were observed after 24 hours of TF wear ('drift phenomenon'). Sleep position affects IOP as measured by TF in some patients with progressive glaucoma. The upward drift in TF output detected in >50% of the subjects requires further investigation to establish whether the increased output values over time are an artefact induced by the TF or a real change in IOP. NCT01351779. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  7. Comparative evaluation of toric intraocular lens alignment and visual quality with image-guided surgery and conventional three-step manual marking.

    PubMed

    Titiyal, Jeewan S; Kaur, Manpreet; Jose, Cijin P; Falera, Ruchita; Kinkar, Ashutosh; Bageshwar, Lalit Ms

    2018-01-01

    To compare toric intraocular lens (IOL) alignment assisted by image-guided surgery or manual marking methods and its impact on visual quality. This prospective comparative study enrolled 80 eyes with cataract and astigmatism ≥1.5 D to undergo phacoemulsification with toric IOL alignment by manual marking method using bubble marker (group I, n=40) or Callisto eye and Z align (group II, n=40). Postoperatively, accuracy of alignment and visual quality was assessed with a ray tracing aberrometer. Primary outcome measure was deviation from the target axis of implantation. Secondary outcome measures were visual quality and acuity. Follow-up was performed on postoperative days (PODs) 1 and 30. Deviation from the target axis of implantation was significantly less in group II on PODs 1 and 30 (group I: 5.5°±3.3°, group II: 3.6°±2.6°; p =0.005). Postoperative refractive cylinder was -0.89±0.35 D in group I and -0.64±0.36 D in group II ( p =0.003). Visual acuity was comparable between both the groups. Visual quality measured in terms of Strehl ratio ( p <0.05) and modulation transfer function (MTF) ( p <0.05) was significantly better in the image-guided surgery group. Significant negative correlation was observed between deviation from target axis and visual quality parameters (Strehl ratio and MTF) ( p <0.05). Image-guided surgery allows precise alignment of toric IOL without need for reference marking. It is associated with superior visual quality which correlates with the precision of IOL alignment.

  8. Patients with Fuchs Endothelial Dystrophy and Cataract Undergoing Descemet Stripping Automated Endothelial Keratoplasty and Phacoemulsification with Intraocular Lens Implant: Staged versus Combined Procedure Outcomes.

    PubMed

    Sykakis, Evripidis; Lam, Fook Chang; Georgoudis, Panagiotis; Hamada, Samer; Lake, Damian

    2015-01-01

    Purpose. To compare the surgical outcomes of staged and combined phacoemulsification with intraocular lens implant (phaco+IOL) and Descemet stripping automated endothelial keratoplasty (DSAEK) in patients with Fuchs' endothelial dystrophy and cataract. Setting. Corneoplastic Unit and Eye Bank, Queen Victoria Hospital, East Grinstead, UK. Methods. Retrospective study of patients who had combined phaco+IOL and DSAEK (group 1) or phaco+IOL followed within 2 months by DSAEK (group 2). Patients who had previous eye surgery or any other ocular comorbidities were excluded. Results. There were 28 eyes in group 1 and 31 in group 2. There were no significant differences in the demographics and corneal tissue characteristics of the two groups. The endothelial disc dislocation and rebubbling rate within 1 week in group 1 was 21.42% and in group 2 was 3.2% (P = 0.04), while the endothelial cell density at 12 months was 1510 ± 433 for group 1 and 1535 ± 482 for group 2 (P = 0.89). The mean 12-month logMAR visual acuity was 0.28 ± 0.24 for group 1 and 0.33 ± 0.15 for group 2 (P = 0.38). Conclusions. Although the combined procedure seems to be associated with a higher complication rate the final outcomes seem to be similar to both methods.

  9. MAHLI First Night Imaging of Martian Rock Under Ultraviolet Lighting

    NASA Image and Video Library

    2013-01-24

    This image of a Martian rock dubbed Sayunei is illuminated by ultraviolet LEDs light emitting diodes is part of the first set of nighttime images taken by the Mars Hand Lens Imagery camera at the end of the robotic arm of NASA Mars rover Curiosity.

  10. In vivo measurement of the average refractive index of the human crystalline lens using optical coherence tomography.

    PubMed

    de Freitas, Carolina; Ruggeri, Marco; Manns, Fabrice; Ho, Arthur; Parel, Jean-Marie

    2013-01-15

    We present a method for measuring the average group refractive index of the human crystalline lens in vivo using an optical coherence tomography (OCT) system which, allows full-length biometry of the eye. A series of OCT images of the eye including the anterior segment and retina were recorded during accommodation. Optical lengths of the anterior chamber, lens, and vitreous were measured dynamically along the central axis on the OCT images. The group refractive index of the crystalline lens along the central axis was determined using linear regression analysis of the intraocular optical length measurements. Measurements were acquired on three subjects of age 21, 24, and 35 years. The average group refractive index for the three subjects was, respectively, n=1.41, 1.43, and 1.39 at 835 nm.

  11. Crystalline lens dislocation secondary to bacterial endogenous endophthalmitis.

    PubMed

    Sangave, Amit; Komati, Rahul; Weinmann, Allison; Samuel, Linoj; Desai, Uday

    2017-09-01

    To present an unusual case of endogenous endophthalmitis secondary to Group A streptococcus (GAS) that resulted in dislocation of the crystalline lens. An immunocompetent 51-year-old man presented to the emergency room (ER) with upper respiratory infection (URI) symptoms and painful right eye. He was diagnosed with URI and viral conjunctivitis and discharged on oral azithromycin and polytrim eyedrops. He returned to the ER 30 h later with sepsis and findings consistent with endophthalmitis, including light perception only vision. Ophthalmology was consulted at this time and an emergent vitreous tap and injection was performed. Both blood and vitreous cultures grew an atypical non-hemolytic variant of GAS ( Streptococcus pyogenes ). The primary source of infection was presumed to be secondary to pharyngitis or cutaneous dissemination. Final vision in the affected eye was no light perception, likely from a combination of anterior segment scarring, posterior segment damage, and hypotony. Interestingly, head computed tomography (CT) at the initial ER presentation showed normal lens position, but repeat CT at re-presentation revealed posterior dislocation of the lens. Endophthalmitis secondary to GAS has been sparsely reported in the literature, and this case highlights a unique clinical presentation. We suspect that this atypical non-hemolytic strain may have evaded detection on initial pharyngeal cultures. Additionally, we hypothesize that GAS-mediated protease release resulted in breakdown of the zonular fibers and subsequent lens dislocation. Ophthalmologists should be aware of GAS and its devastating intraocular manifestations.

  12. LONG-TERM INTRAOCULAR PRESSURE AFTER UNCOMPLICATED PARS PLANA VITRECTOMY FOR IDIOPATHIC EPIRETINAL MEMBRANE.

    PubMed

    Tognetto, Daniele; Pastore, Marco R; Cirigliano, Gabriella; DʼAloisio, Rossella; Borelli, Massimo; De Giacinto, Chiara

    2017-11-16

    To investigate long-term intraocular pressure trends after uncomplicated pars plana vitrectomy for idiopathic epiretinal membrane. Three hundred and sixty-eight eyes of 368 consecutive patients were enrolled. Changes in intraocular pressure 1, 3, 6, and 12 months after surgery and during the final follow-up visit were evaluated in vitrectomized eyes and nonvitrectomized fellow eyes. The median follow-up period was 36 months (range 12-92 months). Longitudinal data analysis evidenced a 2.5-mmHg (2.2 mmHg; 2.7 mmHg, 95% confidence interval) statistically significant difference in intraocular pressure 30 days after surgery between treated and fellow untreated eyes, gradually recovering to a not significant 0.2-mmHg (-0.1 mmHg; 0.4 mmHg, 95% confidence interval) difference within 26 months. The incidence of late-onset ocular hypertension was 5.7% (21 over 347, 2%; 12%, 95% confidence interval) without difference between the treated eyes and the group control. No significant difference in the incidence of late-onset ocular hypertension and sex, lens status, or gauge of vitrectomy instruments was detected. Only patient's age was significantly higher (mean difference 4.2 years; 0.1-8.0 years, Monte Carlo, 95% confidence interval) in those who developed late-onset ocular hypertension in the vitrectomized eye. Uncomplicated pars plana vitrectomy for idiopathic epiretinal membrane seems not to increase the risk of late-onset ocular hypertension or open-angle glaucoma development.

  13. [Correlation of intraocular pressure variation after visual field examination with 24-hour intraocular pressure variations in primary open-angle glaucoma].

    PubMed

    Noro, Takahiko; Nakamoto, Kenji; Sato, Makoto; Yasuda, Noriko; Ito, Yoshinori; Ogawa, Shumpei; Nakano, Tadashi; Tsuneoka, Hiroshi

    2014-10-01

    We retrospectively examined intraocular pressure variations after visual field examination in primary open angle glaucoma (POAG), together with its influencing factors and its association with 24-hour intraocular pressure variations. Subjects were 94 eyes (52 POAG patients) subjected to measurements of 24-hour intraocular pressure and of changes in intraocular pressure after visual field examination using a Humphrey Visual Field Analyzer. Subjects were classified into three groups according to the magnitude of variation (large, intermediate and small), and 24-hour intraocular pressure variations were compared among the three groups. Factors influencing intraocular pressure variations after visual field examination and those associated with the large variation group were investigated. Average intraocular pressure variation after visual field examination was -0.28 ± 1.90 (range - 6.0(-) + 5.0) mmHg. No significant influencing factors were identified. The intraocular pressure at 3 a.m. was significantly higher in the large variation group than other two groups (p < 0.001). Central corneal thickness was correlated with the large variation group (odds ratio = 1.04; 95% confidence interval, 1.01-1.07 ; p = 0.02). No particular tendencies in intraocular pressure variations were found after visual field examination. Increases in intraocular pressure during the night might be associated with large intraocular pressure variations after visual field examination.

  14. Determinants of lens vault and association with narrow angles in patients from Singapore.

    PubMed

    Tan, Gavin S; He, Mingguang; Zhao, Wanting; Sakata, Lisandro M; Li, Jialiang; Nongpiur, Monisha E; Lavanya, Raghavan; Friedman, David S; Aung, Tin

    2012-07-01

    To describe the distribution and determinants of lens vault and to investigate the association of lens vault with narrow angles. Prospective cross-sectional study. Phakic subjects 50 years and older were evaluated at a primary healthcare clinic with gonioscopy, partial laser interferometry, and anterior segment optical coherence tomography (AS-OCT). Narrow angles were defined as posterior trabecular meshwork not visible for ≥2 quadrants on non-indentation gonioscopy. Lens vault was defined as the perpendicular distance between the anterior pole of the crystalline lens and the horizontal line joining the 2 scleral spurs on horizontal AS-OCT scans. Analysis of covariance, multivariate logistic regression, and area under the receiver operating characteristic curves (AUC) were performed. Of the 2047 subjects recruited, 582 were excluded because of poor image quality or inability to locate scleral spurs, leaving 1465 subjects for analysis. Eyes with narrow angles had greater lens vault compared to eyes with open angles (775.6 µm vs 386.5 µm, P < .0001). Women had significantly greater lens vault than men (497.28 µm vs 438.56 µm, P < .001), and lens vault increased significantly with age (P for trend <.001). Adjusted for age and sex, significant associations with greater lens vault were shorter axial length, shallower anterior chamber depth(ACD), higher intraocular pressure, and more hyperopic spherical equivalent (all P < .001). On multivariate analysis, subjects with lens vault >667.6 µm were more likely to have narrow angles (OR 2.201, 95% CI: 1.070-4.526) compared to those with lens vault ≤462.7 µm. The AUC for lens vault (0.816) and ACD (0.822) for detecting narrow angles were similar (P = .582). Lens vault was independently associated with narrow angles and may be useful in screening to detect eyes with narrow angles. Copyright © 2012 Elsevier Inc. All rights reserved.

  15. Long-Term Comparison of Posterior Chamber Phakic Intraocular Lens With and Without a Central Hole (Hole ICL and Conventional ICL) Implantation for Moderate to High Myopia and Myopic Astigmatism: Consort-Compliant Article.

    PubMed

    Shimizu, Kimiya; Kamiya, Kazutaka; Igarashi, Akihito; Kobashi, Hidenaga

    2016-04-01

    The study shows a promising next-generation surgical option for the correction of moderate to high ametropia. Hole implantable collamer lens (ICL), STAAR Surgical, is a posterior chamber phakic intraocular lens with a central artificial hole. As yet, however, no long-term comparison of the clinical results of the implantation of ICLs with and without such a hole has hitherto been conducted. A prospective, randomized, controlled trial was carried out in order to compare the long-term clinical outcomes of the implantation, in such eyes, of ICLs with and without a central artificial hole.Examinations were conducted of the 64 eyes of 32 consecutive patients with spherical equivalents of -7.53 ± 2.39 diopters (D) (mean ± standard deviation) in whom implantation of a Hole ICL was performed in 1 eye, and that of a conventional ICL was carried out in the other, by randomized assignment. Before 1, 3, and 6 months, and 1, 3, and 5 years after surgery, the safety, efficacy, predictability, stability, intraocular pressure, endothelial cell density, and adverse events of the 2 surgical techniques were assessed and compared over time.The measurements of LogMAR uncorrected and corrected distance visual acuity 5 years postoperatively were -0.17 ± 0.14 and -0.24 ± 0.08 in the Hole ICL group, and -0.16 ± 0.10 and -0.25 ± 0.08 in the conventional ICL group. In these 2 groups, 96% and 100% of eyes, respectively, were within 1.0 D of the targeted correction 5 years postoperatively. Manifest refraction changed by -0.17 ± 0.41 D and -0.10 ± 0.26 D occurred in from 1 month to 5 years in the Hole and conventional ICL groups, respectively. Only 1 eye (3.1%), which was in the conventional ICL group, developed an asymptomatic anterior subcapsular cataract.Both Hole and conventional ICLs corrected of ametropia successfully throughout the 5-year observation period. It appears likely that the presence of the central hole does not significantly affect these

  16. Genetics of Primary Intraocular Tumors

    PubMed Central

    Nagarkatti-Gude, Nisha; Wang, Yujuan; Ali, Mohammad Javed; Honavar, Santosh G.; Jager, Martine J.; Chan, Chi-Chao

    2012-01-01

    Primary intraocular neoplasms are tumors that originate within the eye. The most common malignant primary intraocular tumor in adults is uveal melanoma and the second is primary intraocular lymphoma or vitreoretinal (intraocular) lymphoma. The most common malignant intraocular tumor in children is retinoblastoma. Genetics plays a vital role in the diagnosis and detection of ocular tumors. In uveal melanoma, monosomy 3 is the most common genetic alteration and somatic mutations of BAP1, a tumor suppressor gene, have been reported in nearly 50% of primary uveal melanomas. The retinoblastoma gene RB1 is the prototype tumor suppressor gene—mutations in RB1 alleles lead to inactivated RB protein and the development of retinoblastoma. Immunoglobulin heavy chain (IgH) or T-cell receptor (TCR) gene rearrangement is observed in B-cell or T-cell primary vitreoretinal lymphoma, respectively. Other factors related to the genetics of these three common malignancies in the eye are discussed and reviewed. PMID:22834783

  17. [Ultraviolet radiation-induced apoptosis in human lens epithelial cells and its effect on Bcl-2 and Bax].

    PubMed

    Jia, Songbai; Shi, Jingming; Chen, Xuan; Tang, Luosheng

    2012-07-01

    To explore the apoptosis-inducing effect of ultraviolet(UV) radiation on human lens epithelial cells (HLEC), with particular focus on changes in Bcl-2 or Bax expression as possible mechanisms. All experimental groups were exposed to the same UV light source. HLEC were divided into 6 groups according to duration of UV radiation : 0 min group (control group), 5 min group, 10 min group,15 min group, and 30 min group. Analysis on apoptosis of HLEC was performed by flow cytometry analysis (FCA, Annexin V + PI staining). Changes of Bax and Bcl-2 expression in HLEC were detected by hybridization in situ. Apoptosis in HLEC increased with UV exposure time. The expression level of Bax mRNA was increased with the increase of UV exposure time, whereas the expression level of Bcl-2 mRNA decreased with the increase of UV exposure time. The proportion of apoptotic cells was negatively correlated with ratio of Bcl-2/Bax (r=-0.874, P<0.05). UA radiation can induce apoptosis of HLEC in vitro. Bcl-2 and Bax genes may play an important role in regulating this apoptotic process.

  18. Science-Filters Study of Martian Rock Sees Hematite

    NASA Image and Video Library

    2017-11-01

    This false-color image demonstrates how use of special filters available on the Mast Camera (Mastcam) of NASA's Curiosity Mars rover can reveal the presence of certain minerals in target rocks. It is a composite of images taken through three "science" filters chosen for making hematite, an iron-oxide mineral, stand out as exaggerated purple. This target rock, called "Christmas Cove," lies in an area on Mars' "Vera Rubin Ridge" where Mastcam reconnaissance imaging (see PIA22065) with science filters suggested a patchy distribution of exposed hematite. Bright lines within the rocks are fractures filled with calcium sulfate minerals. Christmas Cove did not appear to contain much hematite until the rover team conducted an experiment on this target: Curiosity's wire-bristled brush, the Dust Removal Tool, scrubbed the rock, and a close-up with the Mars Hand Lens Imager (MAHLI) confirmed the brushing. The brushed area is about is about 2.5 inches (6 centimeters) across. The next day -- Sept. 17, 2017, on the mission's Sol 1819 -- this observation with Mastcam and others with the Chemistry and Camera (ChemCam showed a strong hematite presence that had been subdued beneath the dust. The team is continuing to explore whether the patchiness in the reconnaissance imaging may result more from variations in the amount of dust cover rather than from variations in hematite content. Curiosity's Mastcam combines two cameras: one with a telephoto lens and the other with a wider-angle lens. Each camera has a filter wheel that can be rotated in front of the lens for a choice of eight different filters. One filter for each camera is clear to all visible light, for regular full-color photos, and another is specifically for viewing the Sun. Some of the other filters were selected to admit wavelengths of light that are useful for identifying iron minerals. Each of the filters used for this image admits light from a narrow band of wavelengths, extending to only about 5 nanometers longer or

  19. UV solid state laser ablation of intraocular lenses

    NASA Astrophysics Data System (ADS)

    Apostolopoulos, A.; Lagiou, D. P.; Evangelatos, Ch.; Spyratou, E.; Bacharis, C.; Makropoulou, M.; Serafetinides, A. A.

    2013-06-01

    smooth optical surface on the intraocular lens with no irregularities, observed with other wavelengths.

  20. Ultraviolet radiation-blocking characteristics of contact lenses: relevance to eye protection for psoralen-sensitised patients.

    PubMed

    Anstey, A; Taylor, D; Chalmers, I; Ansari, E

    1999-10-01

    Nine brands of contact lens marketed as "UV protective" were tested for ultraviolet (UV) transmission in order to assess potential suitability for psoralen-sensitised patients. UV-transmission characteristics of hydrated lenses was tested with a Bentham monochromator spectro-radiometer system. All lenses showed minimal transmission loss in the visible band. The performance of the nine lenses was uniform for ultraviolet B radiation with negligible transmission, but showed variation in transmission for ultraviolet A radiation. None of the lenses complied with UV-transmission criteria used previously to assess UV-blocking spectacles. Only two lenses had UV-blocking characteristics which came close to the arbitrary criteria used. The performance of ordinary soft and hard lenses was very similar, with negligible blocking of UV radiation. None of the nine contact lenses marketed as "UV protective" excluded sufficient UVA to comply with criteria in current use to assess UV protection in spectacles for psoralen-sensitised patients. However, the improved UV-blocking characteristics of contact lenses identified in this paper compared to previous studies suggests that such a contact lens will soon become available. Meanwhile, contact lens-wearing systemically sensitised PUVA patients should continue to wear approved spectacles for eye protection whilst photosensitised with psoralen.

  1. In-the-bag decentration of an intraocular lens in a patient with a tendency to hypertrophic scarring

    PubMed Central

    Joshi, Rajesh Subhash

    2016-01-01

    Summary We report a case of rapid anterior lens capsular contraction leading to decentration of a hydrophilic acrylic lens with stiff haptics (Rayner design). To our knowledge, this is the first report to investigate early capsular contraction with folding of the haptic over the optic in a patient with a tendency toward hypertrophic scar formation. PMID:27330480

  2. The Relationship between Anterior Chamber Depth, Axial Length and Intraocular Lens Power among Candidates for Cataract Surgery.

    PubMed

    Sedaghat, Mohammad Reza; Azimi, Ali; Arasteh, Peyman; Tehranian, Naghmeh; Bamdad, Shahram

    2016-10-01

    Basic anatomical parameters in ophthalmology are variable in different countries according to ethnic groups, genetics and some environmental factors. The aim of this study was to determine the relationship between axial length (AL), anterior chamber depth (ACD) and intraocular lens power (IOL) in a referral center from eastern Iran among patients who had cataract surgery, in comparison to studies from other regions of the world. In a cross-sectional retrospective study from 2011 to 2013, the records of 698 cataract patients referring to Khatam Al Anbia general hospital in Mashhad, Iran were evaluated. We divided patients, based on their AL and ACD, into three separate groups and compared their results. The SPSS software was used for data analysis. The Chi-Square test and the Independent-samples t-test were used to compare qualitative and quantitative data between two groups, respectively. The Kendall and the Pearson product-moment correlation tests were used to assess the relationship between AL and ACD. The linear Regression model was used to obtain a mathematical model to estimate ACD, using AL, age and sex. Among individuals who had normal AL (between 22-24.5mm), there was a positive correlation between AL and ACD (p<0.001, r=0.17), however, among individuals with short (AL<22mm) or long sightedness (AL>24.5mm), no significant correlation was detected. We also found that older people have shorter AL (p=0.001 and r=-0.287). Men have an average longer AL (23.7±2.4mm vs. 22.9±2.1mm; p<0.001) and deeper ACD compared to women (2.93±0.45mm vs. 2.82±0.42mm, p=0.002). Our findings were mostly similar to previous literature from other regions of the world and although some anatomical variations may exist regarding ophthalmic anatomy, factors like race and geographical area have little effect on the relationship between ACD, AL and IOL power calculation, furthermore our results support the use of third and fourth generation formulas for IOL power calculation.

  3. Image watermarking against lens flare effects

    NASA Astrophysics Data System (ADS)

    Chotikawanid, Piyanart; Amornraksa, Thumrongrat

    2017-02-01

    Lens flare effects in various photo and camera software nowadays can partially or fully damage the watermark information within the watermarked image. We propose in this paper a spatial domain based image watermarking against lens flare effects. The watermark embedding is based on the modification of the saturation color component in HSV color space of a host image. For watermark extraction, a homomorphic filter is used to predict the original embedding component from the watermarked component, and the watermark is blindly recovered by differentiating both components. The watermarked image's quality is evaluated by wPSNR, while the extracted watermark's accuracy is evaluated by NC. The experimental results against various types of lens flare effects from both computer software and mobile application showed that our proposed method outperformed the previous methods.

  4. Utilizing the Southwest Ultraviolet Imaging System (SwUIS) on the International Space Station

    NASA Astrophysics Data System (ADS)

    Schindhelm, Eric; Stern, S. Alan; Ennico-Smith, Kimberly

    2013-09-01

    We present the Southwest Ultraviolet Imaging System (SwUIS), a compact, low-cost instrument designed for remote sensing observations from a manned platform in space. It has two chief configurations; a high spatial resolution mode with a 7-inch Maksutov-Cassegrain telescope, and a large field-of-view camera mode using a lens assembly. It can operate with either an intensified CCD or an electron multiplying CCD camera. Interchangeable filters and lenses enable broadband and narrowband imaging at UV/visible/near-infrared wavelengths, over a range of spatial resolution. SwUIS has flown previously on Space Shuttle flights STS-85 and STS-93, where it recorded multiple UV images of planets, comets, and vulcanoids. We describe the instrument and its capabilities in detail. The SWUIS's broad wavelength coverage and versatile range of hardware configurations make it an attractive option for use as a facility instrument for Earth science and astronomical imaging investigations aboard the International Space Station.

  5. UVB-induced epidermal pigmentation in mice eyes with no contact lens wear and non-UVB blocking and UVB blocking contact lens wear.

    PubMed

    Hiramoto, Keiichi; Kobayashi, Hiromi; Yamate, Yurika; Ishii, Masamitsu; Sato, Takao; Inoue, Masayasu

    2013-02-01

    Irradiation by ultraviolet (UV) B is known to increase the number of Dopa-positive melanocytes in the skin. This study examines the effectiveness of a contact lens for the defense of UVB eye irradiation-induced pigmentation. A 2.5 kJ/m(2) dose of UVB radiation was delivered by a sunlamp to the eye of C57BL/6j male mice, and changes in the expression of Dopa-positive melanocytes in the epidermis and the plasma level of alpha-melanocyte-stimulating hormone (α-MSH) was analyzed. The degree of change in the Dopa-positive melanocytes expression was reduced by UVB blocking contact lens using mice given UVB irradiation to the eye. The plasma level of α-MSH increased in the C57BL/6j mice after irradiation to the eye, but there was no increase in the UVB blocking contact lens mice given UVB irradiation to the eye. Both the increase of the expression of Dopa-positive melanocytes and the plasma level of α-MSH were strongly suppressed by an alignment fitting UVB blocking contact lens and only a slightly suspended UVB blocking contact lens. In addition, these changes were successfully inhibited by a UVB blocking contact lens but not by a non-UVB blocking contact lens with a similar absorbance. These observations suggest that the UVB blocking contact lens inhibits the pigmentation of the epidermis in mice by suppressing of the α-MSH. Copyright © 2012 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  6. Analysis of crystalline lens coloration using a black and white charge-coupled device camera.

    PubMed

    Sakamoto, Y; Sasaki, K; Kojima, M

    1994-01-01

    To analyze lens coloration in vivo, we used a new type of Scheimpflug camera that is a black and white type of charge-coupled device (CCD) camera. A new methodology was proposed. Scheimpflug images of the lens were taken three times through red (R), green (G), and blue (B) filters, respectively. Three images corresponding with the R, G, and B channels were combined into one image on the cathode-ray tube (CRT) display. The spectral transmittance of the tricolor filters and the spectral sensitivity of the CCD camera were used to correct the scattering-light intensity of each image. Coloration of the lens was expressed on a CIE standard chromaticity diagram. The lens coloration of seven eyes analyzed by this method showed values almost the same as those obtained by the previous method using color film.

  7. Performance Analysis of Local Ensemble Kalman Filter

    NASA Astrophysics Data System (ADS)

    Tong, Xin T.

    2018-03-01

    Ensemble Kalman filter (EnKF) is an important data assimilation method for high-dimensional geophysical systems. Efficient implementation of EnKF in practice often involves the localization technique, which updates each component using only information within a local radius. This paper rigorously analyzes the local EnKF (LEnKF) for linear systems and shows that the filter error can be dominated by the ensemble covariance, as long as (1) the sample size exceeds the logarithmic of state dimension and a constant that depends only on the local radius; (2) the forecast covariance matrix admits a stable localized structure. In particular, this indicates that with small system and observation noises, the filter error will be accurate in long time even if the initialization is not. The analysis also reveals an intrinsic inconsistency caused by the localization technique, and a stable localized structure is necessary to control this inconsistency. While this structure is usually taken for granted for the operation of LEnKF, it can also be rigorously proved for linear systems with sparse local observations and weak local interactions. These theoretical results are also validated by numerical implementation of LEnKF on a simple stochastic turbulence in two dynamical regimes.

  8. Broadband diffractive lens or imaging element

    DOEpatents

    Ceglio, Natale M.; Hawryluk, Andrew M.; London, Richard A.; Seppala, Lynn G.

    1993-01-01

    A broadband diffractive lens or imaging element produces a sharp focus and/or a high resolution image with broad bandwidth illuminating radiation. The diffractive lens is sectored or segmented into regions, each of which focuses or images a distinct narrowband of radiation but all of which have a common focal length. Alternatively, a serial stack of minus filters, each with a diffraction pattern which focuses or images a distinct narrowband of radiation but all of which have a common focal length, is used. The two approaches can be combined. Multifocal broadband diffractive elements can also be formed. Thin film embodiments are described.

  9. Broadband diffractive lens or imaging element

    DOEpatents

    Ceglio, Natale M.; Hawryluk, Andrew M.; London, Richard A.; Seppala, Lynn G.

    1991-01-01

    A broadband diffractive lens or imaging element produces a sharp focus and/or a high resolution image with broad bandwidth illuminating radiation. The diffractive lens is sectored or segmented into regions, each of which focuses or images a distinct narrowband of radiation but all of which have a common focal length. Alternatively, a serial stack of minus filters, each with a diffraction pattern which focuses or images a distinct narrowband of radiation but all of which have a common focal length, is used. The two approaches can be combined. Multifocal broadband diffractive elements can also be formed.

  10. Aging and Age-Related Diseases of the Ocular Lens and Vitreous Body

    PubMed Central

    Petrash, J. Mark

    2013-01-01

    Reduced quality of life and financial burden due to visual impairment and blindness begin to increase dramatically when individuals reach the age of 40. The major causes of age-related vision loss can be traced to changes to the structure and function of the lens, one of the tissues responsible for focusing light on the retina. Age-related nuclear cataracts, which are caused by aggregation and condensation of proteins, diminish vision because they impede the transmission and focusing of light on the retina. In addition to the slow-developing age-related form, cataracts often develop rapidly as a complication of ocular surgery, such as following vitrectomy or as a consequence of vitreous gel degeneration. Posterior capsular opacification, which can develop following cataract removal, is caused by proliferation and inappropriate accumulation of lens epithelial cells on the surfaces of intraocular lenses and the posterior lens capsule. Presbyopia is a loss of accommodative amplitude and reduced ability to shift focus from far to near objects. Onset of presbyopia is associated with an increase in lens hardness and reduced ability of the lens to change shape in response to ciliary muscle contraction. Avenues of promising research that seek to delay or prevent these causes of low vision are discussed in light of our current understanding of disease pathogenesis and some challenges that must be met to achieve success. PMID:24335070

  11. Tonopen XL assessment of intraocular pressure through silicone hydrogel contact lenses.

    PubMed

    Schornack, Muriel; Rice, Melissa; Hodge, David

    2012-09-01

    To assess the accuracy of Tonopen XL measurement of intraocular pressure (IOP) through low-power (-0.25 to -3.00) and high power (-3.25 to -6.00) silicone hydrogel lenses of 3 different materials (galyfilcon A, senofilcon A, and lotrafilcon B). Seventy-eight patients were recruited for participation in this study. All were habitual wearers of silicone hydrogel contact lenses, and none had been diagnosed with glaucoma, ocular hypertension, or anterior surface disease. IOP was measured with and without lenses in place in the right eye only. Patients were randomized to initial measurement either with or without the lens in place. A single examiner collected all data. No statistically significant differences were noted between IOP measured without lenses and IOP measured through low-power lotrafilcon B lenses or high-power or low-power galyfilcon A and senofilcon A lenses. However, we did find a statistically significant difference between IOP measured without lenses and IOP measured through high-power lotrafilcon B lenses. In general, Tonopen XL measurement of IOP through silicone hydrogel lenses may be sufficiently accurate for clinical purposes. However, Tonopen XL may overestimate IOP if performed through a silicone hydrogel lens of relatively high modulus.

  12. Clinical and biometric determinants of actual lens position after cataract surgery.

    PubMed

    Plat, Julien; Hoa, Didier; Mura, Frederic; Busetto, Timothe; Schneider, Christelle; Payerols, Arnaud; Villain, Max; Daien, Vincent

    2017-02-01

    To evaluate the preoperative clinical and biometric determinants associated with the actual lens position after cataract surgery. Department of Ophthalmology, University Hospital of Montpellier, France. Prospective longitudinal cohort study. The data collected included clinical factors (age, sex, history of vitrectomy) and biometry factors (axial length [AL], anterior chamber depth [ACD], lens thickness, white-to-white [WTW] distance) that might affect actual lens position. Each patient had optical low-coherence reflectometry biometry (Lenstar) preoperatively and 1 month postoperatively. The actual lens position was measured as the postoperative position of the center of the intraocular lens (IOL). Patients were stratified into 3 groups by type of IOL: Acrysof SN60WF or SN6AT (Group 1), Tecnis ZCB00 or ZCT (Group 2), and Asphina 409 MV (Group 3). The study comprised 168 eyes (mean age 73.3 years ± 9.8 [SD]). The mean actual lens position was 4.88 ± 0.29 mm, 5.01 ± 0.29 mm, and 5.05 ± 0.32 mm in Group 1 (n = 67 eyes), Group 2 (n = 52 eyes), and Group 3 (n = 49 eyes), respectively. In the overall population, AL, ACD, anterior segment depth, and WTW distance were correlated with actual lens position (r = 0.48, P < .0001; r = 0.64, P < .001; r = 0.58, P < .0001; r = 0.39, P < .001, respectively). The AL, ACD, anterior segment depth, and WTW distance correlated with actual lens position after cataract surgery. The integration of these data in IOL formulas could help improve refractive outcomes after the surgery. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  13. Solar ultraviolet radiation cataract.

    PubMed

    Löfgren, Stefan

    2017-03-01

    Despite being a treatable disease, cataract is still the leading cause for blindness in the world. Solar ultraviolet radiation is epidemiologically linked to cataract development, while animal and in vitro studies prove a causal relationship. However, the pathogenetic pathways for the disease are not fully understood and there is still no perfect model for human age related cataract. This non-comprehensive overview focus on recent developments regarding effects of solar UV radiation wavebands on the lens. A smaller number of fundamental papers are also included to provide a backdrop for the overview. Future studies are expected to further clarify the cellular and subcellular mechanisms for UV radiation-induced cataract and especially the isolated or combined temporal and spatial effects of UVA and UVB in the pathogenesis of human cataract. Regardless of the cause for cataract, there is a need for advances in pharmaceutical or other treatment modalities that do not require surgical replacement of the lens. Copyright © 2016. Published by Elsevier Ltd.

  14. Reflective Filters Design for Self-Filtering Narrowband Ultraviolet Imaging Experiment Wide-Field Surveys (NUVIEWS) Project

    NASA Technical Reports Server (NTRS)

    Park, Jung- Ho; Kim, Jongmin; Zukic, Muamer; Torr, Douglas G.

    1994-01-01

    We report the design of multilayer reflective filters for the self-filtering cameras of the NUVIEWS project. Wide angle self-filtering cameras were designed to image the C IV (154.9 nm) line emission, and H2 Lyman band fluorescence (centered at 161 nm) over a 20 deg x 30 deg field of view. A key element of the filter design includes the development of pi-multilayers optimized to provide maximum reflectance at 154.9 nm and 161 nm for the respective cameras without significant spectral sensitivity to the large cone angle of the incident radiation. We applied self-filtering concepts to design NUVIEWS telescope filters that are composed of three reflective mirrors and one folding mirror. The filters with narrowband widths of 6 and 8 rim at 154.9 and 161 nm, respectively, have net throughputs of more than 50 % with average blocking of out-of-band wavelengths better than 3 x 10(exp -4)%.

  15. Comparison of Toric Foldable Iris-Fixated Phakic Intraocular Lens Implantation and Limbal Relaxing Incisions for Moderate-to-High Myopic Astigmatism

    PubMed Central

    Lee, Jeihoon; Lee, Hun; Kang, David Sung Yong; Choi, Jin Young; Kim, Eung Kweon

    2016-01-01

    Purpose To compare the effectiveness of toric foldable iris-fixated phakic intraocular lens (pIOL) implantation and non-toric foldable iris-fixated pIOL implantation with limbal relaxing incisions (LRIs) for correcting moderate-to-high astigmatism in myopic eyes. Materials and Methods The medical records of 146 patients (195 eyes) with myopic astigmatism who underwent toric foldable iris-fixated pIOL implantation (toric group; 94 eyes) or non-toric foldable iris-fixated pIOL implantation with concurrent LRIs (LRI group; 101 eyes) were retrospectively reviewed. For subgroup analysis, the two groups were subdivided according to preoperative astigmatic severity [moderate, 2.00 to <3.00 diopters (D); high, 3.00–4.00 D]. Visual and astigmatic outcomes were compared 6 months postoperatively. Results The uncorrected distance visual acuity was at least 20/25 in 100% and 98% of the toric and LRI group eyes, respectively. The toric group had lower mean residual cylindrical error (-0.67±0.39 D vs. -1.14±0.56 D; p<0.001) and greater mean cylindrical error change (2.17±0.56 D vs. 1.63±0.72 D; p<0.001) than the LRI group, regardless of the preoperative astigmatic severity. The mean correction index (1.10±0.16 vs. 0.72±0.24; p<0.001) and success index (0.24±0.14 vs. 0.42±0.21; p<0.001) also differed significantly between the groups. Conclusion Both surgical techniques considerably reduced astigmatism and had comparable visual outcomes. However, toric foldable iris-fixated pIOL implantation was more reliable for correcting moderate-to-high astigmatism in myopic eyes. PMID:27593877

  16. Comparative evaluation of toric intraocular lens alignment and visual quality with image-guided surgery and conventional three-step manual marking

    PubMed Central

    Titiyal, Jeewan S; Kaur, Manpreet; Jose, Cijin P; Falera, Ruchita; Kinkar, Ashutosh; Bageshwar, Lalit MS

    2018-01-01

    Purpose To compare toric intraocular lens (IOL) alignment assisted by image-guided surgery or manual marking methods and its impact on visual quality. Patients and methods This prospective comparative study enrolled 80 eyes with cataract and astigmatism ≥1.5 D to undergo phacoemulsification with toric IOL alignment by manual marking method using bubble marker (group I, n=40) or Callisto eye and Z align (group II, n=40). Postoperatively, accuracy of alignment and visual quality was assessed with a ray tracing aberrometer. Primary outcome measure was deviation from the target axis of implantation. Secondary outcome measures were visual quality and acuity. Follow-up was performed on postoperative days (PODs) 1 and 30. Results Deviation from the target axis of implantation was significantly less in group II on PODs 1 and 30 (group I: 5.5°±3.3°, group II: 3.6°±2.6°; p=0.005). Postoperative refractive cylinder was −0.89±0.35 D in group I and −0.64±0.36 D in group II (p=0.003). Visual acuity was comparable between both the groups. Visual quality measured in terms of Strehl ratio (p<0.05) and modulation transfer function (MTF) (p<0.05) was significantly better in the image-guided surgery group. Significant negative correlation was observed between deviation from target axis and visual quality parameters (Strehl ratio and MTF) (p<0.05). Conclusion Image-guided surgery allows precise alignment of toric IOL without need for reference marking. It is associated with superior visual quality which correlates with the precision of IOL alignment. PMID:29731603

  17. AcrySof Natural SN60AT versus AcrySof SA60AT intraocular lens in patients with color vision defects.

    PubMed

    Raj, Shetal M; Vasavada, Abhay R; Nanavaty, Mayank A

    2005-12-01

    To determine whether implantation of the AcrySof Natural intraocular lens (IOL) worsened the severity of existing color deficit in congenital partial red-green color deficient individuals (CPRG). A prospective controlled randomized double-masked analysis of 30 consecutive patients with CPRG defect and bilateral cataracts received a Natural IOL (test group) in 1 eye and a single-piece AcrySof IOL (control group) in the other eye. Patients were tested unilaterally to detect CPRG defect using Ishihara pseudoisochromatic plates and the Farnsworth D-15 test. Plates 1 to 21 measured the Ishihara error score; plates 22 to 25 indicated severity of defect based on clarity of both numerals as partial mild/moderate (both visible), partial severe defect (only 1 visible). The D-15 test is based on number of diametrical crossings on the circular diagram; severity is graded as mild (1 crossing), moderate (2 crossings), or severe (>2 crossings). Tests were performed before and after IOL implantation at 1, 3, and 6 months. At mean follow-up of 6.13 months +/- 1.2 (SD), analysis of variance test judged the difference in error scores and cross tabulation represented change in number of diametrical crossings. The mean age was 62.3 +/- 8.5 years. All patients were men. Before IOL implantation, all patients had moderate CPRG defect on both tests. The Ishihara error score in the test and control groups did not reveal statistically significant differences (P = .505 and P = .119, respectively). With D-15, none of the patients in the test or control group showed >2 crossings. The implantation of AcrySof Natural IOL did not worsen the preexisting severity of color defect in CPRG individuals.

  18. Effect of the equivalent refractive index on intraocular lens power prediction with ray tracing after myopic laser in situ keratomileusis.

    PubMed

    Canovas, Carmen; van der Mooren, Marrie; Rosén, Robert; Piers, Patricia A; Wang, Li; Koch, Douglas D; Artal, Pablo

    2015-05-01

    To determine the impact of the equivalent refractive index (ERI) on intraocular lens (IOL) power prediction for eyes with previous myopic laser in situ keratomileusis (LASIK) using custom ray tracing. AMO B.V., Groningen, the Netherlands, and the Department of Ophthalmology, Baylor College of Medicine, Houston, Texas, USA. Retrospective data analysis. The ERI was calculated individually from the post-LASIK total corneal power. Two methods to account for the posterior corneal surface were tested; that is, calculation from pre-LASIK data or from post-LASIK data only. Four IOL power predictions were generated using a computer-based ray-tracing technique, including individual ERI results from both calculation methods, a mean ERI over the whole population, and the ERI for normal patients. For each patient, IOL power results calculated from the four predictions as well as those obtained with the Haigis-L were compared with the optimum IOL power calculated after cataract surgery. The study evaluated 25 patients. The mean and range of ERI values determined using post-LASIK data were similar to those determined from pre-LASIK data. Introducing individual or an average ERI in the ray-tracing IOL power calculation procedure resulted in mean IOL power errors that were not significantly different from zero. The ray-tracing procedure that includes an average ERI gave a greater percentage of eyes with an IOL power prediction error within ±0.5 diopter than the Haigis-L (84% versus 52%). For IOL power determination in post-LASIK patients, custom ray tracing including a modified ERI was an accurate procedure that exceeded the current standards for normal eyes. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  19. Comparison of Toric Foldable Iris-Fixated Phakic Intraocular Lens Implantation and Limbal Relaxing Incisions for Moderate-to-High Myopic Astigmatism.

    PubMed

    Lee, Jeihoon; Lee, Hun; Kang, David Sung Yong; Choi, Jin Young; Kim, Eung Kweon; Kim, Tae Im

    2016-11-01

    To compare the effectiveness of toric foldable iris-fixated phakic intraocular lens (pIOL) implantation and non-toric foldable iris-fixated pIOL implantation with limbal relaxing incisions (LRIs) for correcting moderate-to-high astigmatism in myopic eyes. The medical records of 146 patients (195 eyes) with myopic astigmatism who underwent toric foldable iris-fixated pIOL implantation (toric group; 94 eyes) or non-toric foldable iris-fixated pIOL implantation with concurrent LRIs (LRI group; 101 eyes) were retrospectively reviewed. For subgroup analysis, the two groups were subdivided according to preoperative astigmatic severity [moderate, 2.00 to <3.00 diopters (D); high, 3.00-4.00 D]. Visual and astigmatic outcomes were compared 6 months postoperatively. The uncorrected distance visual acuity was at least 20/25 in 100% and 98% of the toric and LRI group eyes, respectively. The toric group had lower mean residual cylindrical error (-0.67±0.39 D vs. -1.14±0.56 D; p<0.001) and greater mean cylindrical error change (2.17±0.56 D vs. 1.63±0.72 D; p<0.001) than the LRI group, regardless of the preoperative astigmatic severity. The mean correction index (1.10±0.16 vs. 0.72±0.24; p<0.001) and success index (0.24±0.14 vs. 0.42±0.21; p<0.001) also differed significantly between the groups. Both surgical techniques considerably reduced astigmatism and had comparable visual outcomes. However, toric foldable iris-fixated pIOL implantation was more reliable for correcting moderate-to-high astigmatism in myopic eyes.

  20. Visual Results Following Implantation of a Refractive Multifocal Intraocular Lens in One Eye and a Diffractive in the Contralateral Eye

    PubMed Central

    Yıldırım Karabağ, Revan; Günenç, Üzeyir; Aydın, Rukiye; Arıkan, Gül; Aslankara, Hüseyin

    2018-01-01

    Objectives To assess the visual outcomes in patients who underwent cataract surgery with multifocal intraocular lens (IOL) implantation using a “mix and match” approach. Materials and Methods Twenty patients (40 eyes) were involved in this prospective, nonrandomized study. Refractive multifocal IOLs (ReZoom NXG1) were implanted in patients’ dominant eyes and diffractive multifocal IOLs (Tecnis ZMA00) were implanted in their non-dominant eyes. Monocular and binocular uncorrected distance, intermediate and near visual acuity (logMAR), and contrast sensitivity levels were measured at 1, 3, and 6 months after cataract surgery. Defocus curves, reading speeds, patient satisfaction, spectacle dependence, and halo and glare symptoms were also evaluated at 6 months after the surgery. Postoperative quality of life was assessed with the Turkish version of National Eye Institute Visual Function Questionnaire-25. Results The study group comprised 8 females and 12 males with a mean age of 69.45±10.76 years (range, 31-86 years). The uncorrected distance and intermediate visual acuity levels were significantly better in the ReZoom-implanted eyes at postoperative 6 months (p=0.026 and p=0.037, respectively). There was no statistically significant difference in uncorrected near visual acuity (p>0.05). There was no statistically significant difference in contrast sensitivity, reading speed, halos, or glare between the groups (p<0.05). Mild glare/halo was reported by 40% of the subjects. The mean patient satisfaction was 95% and all patients were spectacle independent. Conclusion Mixing and matching multifocal IOLs in selected cataract patients provides excellent visual outcome, a high level of patient satisfaction, and spectacle independency. PMID:29576891