Sample records for umbilical coiling index

  1. Evidence-based pathology: umbilical cord coiling.

    PubMed

    Khong, T Y

    2010-12-01

    The generation of a pathology test result must be based on criteria that are proven to be acceptably reproducible and clinically relevant to be evidence-based. This review de-constructs the umbilical cord coiling index to illustrate how it can stray from being evidence-based. Publications related to umbilical cord coiling were retrieved and analysed with regard to how the umbilical coiling index was calculated, abnormal coiling was defined and reference ranges were constructed. Errors and other influences that can occur with the measurement of the length of the umbilical cord or of the number of coils can compromise the generation of the coiling index. Definitions of abnormal coiling are not consistent in the literature. Reference ranges defining hypocoiling or hypercoiling have not taken those potential errors or the possible effect of gestational age into account. Even the way numerical test results in anatomical pathology are generated, as illustrated by the umbilical coiling index, warrants a critical analysis into its evidence base to ensure that they are reproducible or free from errors.

  2. The relation between umbilical cord characteristics and the outcome of external cephalic version.

    PubMed

    Kuppens, Simone M I; Waerenburgh, Evelyne R; Kooistra, Libbe; van der Donk, Riet W P; Hasaart, Tom H M; Pop, Victor J M

    2011-05-01

    Umbilical cords of fetuses in breech presentation differ in length and coiling from their cephalic counterparts and it might be hypothesised that these cord characteristics may in turn affect ECV outcome. To investigate the relation between umbilical cord characteristics and the outcome of external cephalic version (ECV). Prospective cohort study. Women (>35 weeks gestation) with a singleton fetus in breech presentation, suitable for external cephalic version. Demographic, lifestyle and obstetrical parameters were assessed at intake. ECV success was based on cephalic presentation on ultrasound post-ECV. Umbilical cord length (UCL) and umbilical coiling index (UCI) were measured after birth. The relation between umbilical cord characteristics (cord length and coiling) and the success of external cephalic version. ECV success rate was overall 79/146 (54%), for multiparas 37/46(80%) and for nulliparas 42/100 (42%). Multiple logistic regression showed that UCL (OR: 1.04, CI: 1.01-1.07), nulliparity (OR: 0.20, CI: 0.08-0.51), frank breech (OR: 0.37, 95% CI: 0.15-0.90), body mass index (OR: 0.85, CI: 0.76-0.95), placenta anterior (OR: 0.27, CI: 0.12-0.63) and birth weight (OR: 1.002, CI: 1.001-1.003) were all independently related to ECV success. Umbilical cord length is independently related to the outcome of ECV, whereas umbilical coiling index is not. Copyright © 2011 Elsevier Ltd. All rights reserved.

  3. A case report of umbilical ring constriction with application of amnioinfusion.

    PubMed

    Tokunaka, Mayumi; Hasegawa, Junichi; Nakamura, Masamitsu; Hamada, Shoko; Matsuoka, Ryu; Ichizuka, Kiyotake; Sekizawa, Akihiko; Okai, Takashi

    2013-07-01

    This is a case report of a pregnant 38-year-old primigravida woman. Due to severe fetal growth restriction and oligohydramnios, she was referred to our tertiary perinatal center at 24 weeks' gestation. To rule out chromosomal abnormalities and facilitate ultrasound evaluation of fetal morphology, we performed amniocentesis and subsequent amnioinfusion. Thereafter, a precise ultrasound examination revealed no obvious fetal morphological abnormalities except for a hyper-coiled cord and marginal placenta previa. During expectant management, the amount of amniotic fluid was maintained at 20-26 mm for a few days; however, the pregnancy resulted in intrauterine fetal death after 26 weeks + 5 days of gestation. The stillborn infant weighed 530 g (-3.3 SD) and had no obvious external abnormalities apart from umbilical ring constriction. Although a postmortem autopsy was not performed, it is suspected that the fetal growth restriction and the intrauterine fetal death were associated with the hyper-coiled cord and the umbilical ring constriction. It is thought that umbilical ring constriction might therefore be an irreversible fatal condition in cases with a hyper-coiled cord.

  4. [Assessment of blood flow in the middle cerebral artery and the umbilical artery in fetuses with umbilical venous pulsations].

    PubMed

    Borowski, Dariusz; Czuba, Bartosz; Kaczmarek, Piotr; Włoch, Agata; Pawłowicz, Paweł; Wyrwas, Dorota; Wielgos, Mirosław; Sodowski, Krzysztof; Szaflik, Krzysztof

    2006-03-01

    Umbilical venous pulsation is an important sign of hemodynamic compromise, especially during fetal heart failure and asphyxia. The aim of this study was to determine of the blow flow in the middle cerebral artery and the umbilical artery in fetuses with umbilical venous pulsations. The investigation included 18 fetuses with signs of the intrauterine growth restriction and umbilical venous pulsations after 28th weeks of gestation. We evaluated cerebral-placental ratio (CPR) and pulsation index (PI) in the middle cerebral artery (MCA) and the umbilical artery (UA). We observed brain sparring effect in all cases of analyzing fetuses. There were 77,8% of abnormal flow pattern in umbilical artery. 13 fetuses had a single pulsation pattern in umbilical vein and another 5 had double pulsation pattern. The coexistence of umbilical vein pulsation and abnormal flow pattern in umbilical artery is closely related to increased perinatal mortality.

  5. Umbilical Deployment Device

    NASA Technical Reports Server (NTRS)

    Shafer, Michael W.; Gallon, John C.; Rivellini, Tommaso P.

    2011-01-01

    The landing scheme for NASA's next-generation Mars rover will encompass a novel landing technique (see figure). The rover will be lowered from a rocket-powered descent stage and then placed onto the surface while hanging from three bridles. Communication between the rover and descent stage will be maintained through an electrical umbilical cable, which will be deployed in parallel with structural bridles. The -inch (13-mm) umbilical cable contains a Kevlar rope core, around which wires are wrapped to create a cable. This cable is helically coiled between two concentric truncated cones. It is deployed by pulling one end of the cable from the cone. A retractable mechanism maintains tension on the cable after deployment. A break-tie tethers the umbilical end attached to the rover even after the cable is cut after touchdown. This break-tie allows the descent stage to develop some velocity away from the rover prior to the cable releasing from the rover deck, then breaks away once the cable is fully extended. The descent stage pulls the cable up so that recontact is not made. The packaging and deployment technique can store a long length of cable in a relatively small volume while maintaining compliance with the minimum bend radius requirement for the cable being deployed. While the packaging technique could be implemented without the use of break-ties, they were needed in this design due to the vibratory environment and the retraction required by the cable. The break-ties used created a series of load-spikes in the deployment signature. The load spikes during the deployment of the initial three coils of umbilical showed no increase between the different temperature trials. The cold deployment did show an increased load requirement for cable extraction in the region where no break-ties were used. This increase in cable drag was superimposed on the loads required to rupture the last set of break-ties, and as such, these loads saw significant increase when compared to their ambient counterparts. While the loads showed spikes of high magnitude, they were of short duration. Because of this, neither the deployment of the rover, nor the motion of the descent stage, would be adversely affected. In addition, the umbilical was found to have a maximum of 1.2 percent chance for recontact with the ultra-high frequency antenna due to the large margin of safety built in.

  6. [Correlation analysis of the pre-pregnant body mass index, the gestational weight gain and umbilical cord blood C peptide].

    PubMed

    Chen, X L; Han, Y; Zhao, X M; Liu, Y; Lü, J J

    2017-01-03

    Objective: To explore the correlation among the pre-pregnant body mass index (BMI), gestational weight gain (GWG) and umbilical cord blood C peptide, and to investigate the influence of maternal weight management on the incidence of baby long-term metabolic syndrome. Methods: During May to Aug.2015, 485 pregnant women in Zhejiang Taizhou first people's hospital and Taizhou Huangyan maternal &child care service centre were selected in random and divided into four groups according to pre-pregnant BMI: low body mass, normal body mass, over body mass and obese group, and also divided into two groups for getting gestational diabetes mellitus (GDM) or not. According to the gestational weight gain (GWG), all the cases were divided into two groups: above the Institute Of Medicine (IMO) 2009 recommendations or not. According to the outcome, the GDM group which had received weight control treatment, was divided into successful treat group or not. At last, we tested the umbilical cord blood C peptide and birth weight of each newborn and compared the difference in all subgroups. The correlation between the umbilical cord blood C peptide and birth weight were analysed. Results: (1) In the pre-pregnant BMI groups, there were significant differences of incidence of GDM ( P <0.05). But, there were no significant differences of incidence of GWG in four groups ( P >0.05). (2) Newborn birth weight and the umbilical cord blood C peptide were positively correlated ( r =0.673, P <0.05). (3) Umbilical cord blood C peptide showed the correlation in all subgroups for different pre-pregnant BMI, GDM or not, overweight or not ( P <0.05), but only the GDM or not group had relation to newborn birth weight in all subgroups. (4) All groups showed correlations with neonatal umbilical cord blood C peptide, the GDM mostly (β=0.58), pre-pregnant BMI secondly (β: 0.36, 0.38) , and GWG weakly (β=0.17). (5) By stratification analysis, in GDM group, low body mass was negatively correlated with umbilical cord blood C peptide ( P <0.05, β=-1.41); in non-GDM group, over body mass group and obsess group were positively correlated with umbilical cord blood C peptide ( P <0.05, β=0.37, 0.46). Conclusion: There was direct correlation between the pre-pregnant body mass index, the gestational weight gain and umbilical cord blood C peptide. Suitable maternal weight control especially pre-pregnant body mass index control will lower the baby long-term metabolic syndrome incidence.

  7. Assessment of umbilical artery flow and fetal heart rate to predict delivery time in bitches.

    PubMed

    Giannico, Amália Turner; Garcia, Daniela Aparecida Ayres; Gil, Elaine Mayumi Ueno; Sousa, Marlos Gonçalves; Froes, Tilde Rodrigues

    2016-10-15

    The aim of this study was to quantitatively investigate the oscillation of the fetal heart rate (HR) in advance of normal delivery and whether this index could be used to indicate impending delivery. In addition, fetal HR oscillation and umbilical artery resistive index (RI) were correlated to determine if the combination of these parameters provided a more accurate prediction of the time of delivery. Sonographic evaluation was performed in 11 pregnant bitches to evaluate the fetal HR and umbilical artery RI at the following antepartum times: 120 to 96 hours, 72 to 48 hours, 24 to 12 hours, and 12 to 1 hours. Statistical analysis indicated a correlation between the oscillation of fetal HR and the umbilical artery RI. As delivery approached a considerable reduction in the umbilical artery RI was documented and greater oscillations between maximum and minimum HRs occurred. We conclude that the quantitative analysis of fetal HR oscillations may be used to predict the time of delivery in bitches. The combination of fetal HR and umbilical artery RI together may provide more accurate predictions of time of delivery. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Umbilical hernia with cholelithiasis and hiatal hernia: a clinical entity similar to Saint's triad.

    PubMed

    Yamanaka, Takahiro; Miyazaki, Tatsuya; Kumakura, Yuji; Honjo, Hiroaki; Hara, Keigo; Yokobori, Takehiko; Sakai, Makoto; Sohda, Makoto; Kuwano, Hiroyuki

    2015-01-01

    We experienced two cases involving the simultaneous presence of cholelithiasis, hiatal hernia, and umbilical hernia. Both patients were female and overweight (body mass index of 25.0-29.9 kg/m(2)) and had a history of pregnancy and surgical treatment of cholelithiasis. Additionally, both patients had two of the three conditions of Saint's triad. Based on analysis of the pathogenesis of these two cases, we consider that these four diseases (Saint's triad and umbilical hernia) are associated with one another. Obesity is a common risk factor for both umbilical hernia and Saint's triad. Female sex, older age, and a history of pregnancy are common risk factors for umbilical hernia and two of the three conditions of Saint's triad. Thus, umbilical hernia may readily develop with Saint's triad. Knowledge of this coincidence is important in the clinical setting. The concomitant occurrence of Saint's triad and umbilical hernia may be another clinical "tetralogy."

  9. Recurrent umbilical cord accidents in a bottlenose dolphin Tursiops truncatus.

    PubMed

    García-Párraga, Daniel; Brook, Fiona; Crespo-Picazo, José Luís; Alvaro, Teresa; Valls, Mónica; Penadés, Mariola; Ortega, Joaquín; Corpa, Juan Manuel

    2014-02-19

    Three successive umbilical cord accidents (UCAs) were diagnosed in the same female bottlenose dolphin Tursiops truncatus during consecutive gestations. In 2 of these, transabdominal ultrasonographic examination revealed coiling of the UC around the peduncle of the foetus. All 3 foetuses were male, died in utero during the last third of gestation and were spontaneously aborted. The 3 UCs were elongated, flattened and congested. For 3 subsequent pregnancies, a different sire was used for mating, handling protocols and treatments were adjusted, and 3 live female calves were successfully delivered. UC lengths were normal. UCAs are associated with excessively long UCs and are not uncommon in humans and horses but are unusual in other species. We believe this is the first detailed report of recurrent UCAs in a dolphin.

  10. Effect of maternal activity during gestation on maternal behavior, fetal growth, umbilical blood flow, and farrowing characteristics in pigs.

    PubMed

    Harris, E K; Berg, E P; Berg, E L; Vonnahme, K A

    2013-02-01

    Yorkshire gilts either remained in their individual stall from d 40 to term (CON; n = 7) or were subjected to exercise for 30 min 3 times per week from mid to late gestation (EX; n = 7) to determine the impact of increased maternal activity during gestation on maternal behavior, fetal growth, umbilical blood flow, and parturition. In parity 1, maternal body composition (10th rib back fat and LM area), maternal behavior, and farrowing characteristics were recorded. In parities 1 and 2, fetal growth, fetal heart rate, pulsatility index and resistance index, and umbilical blood flow were monitored beginning at d 39 of gestation continuing to d 81 of gestation. Exercise continued until d 104. Gilts allowed to exercise sat less (P < 0.01), stood more (P < 0.01), tended (P = 0.06) to lie down less, and had fewer postural changes (P < 0.01) compared with CON gilts. Umbilical blood flow increased (P < 0.01) in EX compared with CON gilts. Moreover, gilts had greater (P < 0.01) umbilical blood flow in their first parity compared with their second. Indices of vascular resistance were not affected (P ≥ 0.15) by maternal treatment; however, EX gilts reached peak pulsatility index earlier than CON gilts (56.2 vs. 64.3 ± 3.6 d). Fetal weights, piglet birth weights, placental weight, interval between piglet births, and blood lactate of newborn piglets were unaffected (P ≥ 0.15) by maternal treatment. Although maternal exercise during gestation in the pig increased umbilical blood flow and appeared to reduce maternal restlessness, impacts on offspring development in postnatal life are not known.

  11. [Changes in index-F and index-delta 4P in normal pregnancy, labor and the puerperium].

    PubMed

    Kamada, T

    1984-04-01

    Index-F and index-delta 4P (cortisol and progesterone which are not bound to corticosteroid-binding globulin (CBG) in the umbilical cord vein and the maternal blood were determined during pregnancy, at delivery and puerperium. Index-F and index-delta 4P were calculated as the total cortisol or total progesterone X% unbound to CBG divided by 100. The level of index-F showed a gradual rise during pregnancy, and in late pregnancy reached about 1.5 times as high as that of non-pregnant women, whereas the total cortisol level was about 3.3 times. Near delivery, index-F was almost completely stable, but at delivery, it increased suddenly in proportion to the rise in the total cortisol level. This rise is probably due to stress. In the umbilical cord vein blood, the level of index-F was 1.5 times higher than that in the maternal plasma before delivery; however the total cortisol level was lower than that of the maternal plasma. The levels of both index-delta 4P and total progesterone showed a gradual increase during pregnancy in parallel, and each value in late pregnancy was about 4.5 to 4.9 times that of early pregnant women. At or near delivery, the level of index-delta 4P was almost stable and no decrease occurred. In the umbilical cord vein plasma, the levels of index-delta 4P and total progesterone were extremely high. However, the meaning of these results isn't clear.

  12. Effect of low-sodium diet on uteroplacental circulation.

    PubMed

    Delemarre, F M; van Leest, L A; Jongsma, H W; Steegers, E A

    2000-01-01

    To study the influence of chronic dietary sodium restriction on uteroplacental circulation. In a randomized trial, Doppler flow velocity waveforms of the uterine and umbilical artery were studied at monthly intervals during pregnancy in 59 women on a low-sodium diet and in 68 controls. Pulsatility index (PI), resistance index (RI), and A/B ratio of the uterine artery were significantly lower during sodium restriction, whereas PI, RI, and A/B ratio of the umbilical artery were significantly higher. The lower resistance indices of the uterine artery during sodium restriction might reflect an increase in pulse pressure/impedance ratio as a result of activation of the renin-angiotensin system. The increase in umbilical artery resistance indices supports the hypothesis that fetal circulation might be altered by chronic dietary sodium restriction.

  13. Risk Factors for the Development of Refeeding Syndrome-Like Hypophosphatemia in Very Low Birth Weight Infants

    PubMed Central

    Okuno, Takashi; Ohta, Genrei; Tokuriki, Shuko

    2017-01-01

    Background Refeeding syndrome is characterized by metabolic disturbance including hypophosphatemia and hypokalemia upon reinstitution of nutrition in severely malnourished patients. Objective The present study sought to identify the risk factors for the development of refeeding syndrome-like metabolic disturbance in very low birth weight infants. Methods The correlations of severe hypophosphatemia with the serum levels of potassium and ionized calcium, daily calorie and phosphate intake, and umbilical cord blood flow on ultrasonography were analyzed in 49 very low birth weight infants. Results Fifteen infants (36%) presented with hypophosphatemia during the first postnatal week. Hypophosphatemia was significantly associated with birth weight z score (odds ratio, 1.60; 95% confidence interval, 1.04–2.47; p = 0.034) and umbilical artery resistance index (odds ratio, 7.72E−04; 95% confidence interval, 1.14E−06–0.523; p = 0.031). Multiple regression analysis revealed that umbilical artery resistance index was independently associated with hypophosphatemia. Conclusions Umbilical artery resistance index may serve as a useful marker for future development of refeeding syndrome-like hypophosphatemia in very low birth weight infants. Close monitoring of serum phosphorus and potassium levels and early intervention are important for the management of very low birth weight infants with intrauterine growth restriction due to placental dysfunction. PMID:29104345

  14. Risk Factors for the Development of Refeeding Syndrome-Like Hypophosphatemia in Very Low Birth Weight Infants.

    PubMed

    Igarashi, Aiko; Okuno, Takashi; Ohta, Genrei; Tokuriki, Shuko; Ohshima, Yusei

    2017-01-01

    Refeeding syndrome is characterized by metabolic disturbance including hypophosphatemia and hypokalemia upon reinstitution of nutrition in severely malnourished patients. The present study sought to identify the risk factors for the development of refeeding syndrome-like metabolic disturbance in very low birth weight infants. The correlations of severe hypophosphatemia with the serum levels of potassium and ionized calcium, daily calorie and phosphate intake, and umbilical cord blood flow on ultrasonography were analyzed in 49 very low birth weight infants. Fifteen infants (36%) presented with hypophosphatemia during the first postnatal week. Hypophosphatemia was significantly associated with birth weight z score (odds ratio, 1.60; 95% confidence interval, 1.04-2.47; p = 0.034) and umbilical artery resistance index (odds ratio, 7.72 E -04; 95% confidence interval, 1.14 E -06-0.523; p = 0.031). Multiple regression analysis revealed that umbilical artery resistance index was independently associated with hypophosphatemia. Umbilical artery resistance index may serve as a useful marker for future development of refeeding syndrome-like hypophosphatemia in very low birth weight infants. Close monitoring of serum phosphorus and potassium levels and early intervention are important for the management of very low birth weight infants with intrauterine growth restriction due to placental dysfunction.

  15. Characteristics of the umbilical artery velocity waveform as function of measurement site.

    PubMed

    Ruissen, C J; von Drongelen, M M; Hoogland, H J; Jager, W; Hoeks, A P

    1990-01-01

    In 30 uncomplicated singleton pregnancies, varying in duration between 24 and 40 weeks, the variability of the flow velocity waveform (FVW) along the course of the umbilical artery was investigated. Blood flow velocities were recorded at 4 locations in the vessel: within the fetal abdomen, 0-5 cm from the origin of the umbilical cord, in the free-floating part, and 0-5 cm from its insertion in the placenta. From the Doppler signals recorded, the pulsatility index (PI) and a parameter for the frequency distribution index (FDI) were calculated. PI values differed among the locations, but no unequivocal tendency could be demonstrated. Statistical analysis, including multiple regression analysis for maternal and menstrual age and fetal heart rate, showed no significant difference in PI and FDI values for any of the 4 locations. It can be concluded that in uncomplicated pregnancies, possible changes in FVW (quantified by PI) along the course of the umbilical artery have no clinical relevance. Therefore, standardization for the sampling site when measuring PI in this vessel seems to be unnecessary.

  16. Concomitant abdominoplasty and umbilical hernia repair using the Ventralex hernia patch.

    PubMed

    Neinstein, Ryan M; Matarasso, Alan; Abramson, David L

    2015-04-01

    Patients requesting abdominoplasty often have concomitant umbilical hernias and may request simultaneous treatment. The vascularity of the umbilicus is potentially at risk during these combined procedures. In this study, the authors present a technique for treating umbilical hernias at the time of abdominoplasty surgery using the Ventralex hernia patch. A total of 11 female patients with a mean age of 39.4 years (range, 28 to 51 years) undergoing abdominoplasty with umbilical hernia repair with the Ventralex patch were included. The mean body mass index was 27.6 kg/m (range, 20 to 34 kg/m). No vascular compromise of the umbilicus was seen. The hernia repair did not alter the abdominoplasty results. One patient had transient umbilical swelling postoperatively that resolved within 6 months postoperatively. The authors present a series of umbilical hernia repairs in abdominoplasty patients using a minimal access incision by means of the rectus fascia and the Ventralex patch that is fast and reliable and preserves the blood supply to the umbilicus.

  17. Maternal pre-gravid body mass index and adiposity influence umbilical cord gene expression at term in AGA infants

    USDA-ARS?s Scientific Manuscript database

    While maternal obesity is associated with unfavorable maternal and fetal outcomes, the influence of maternal obesity on fetal gene expression is less clear. Umbilical cords (UC) from 12 lean (pre-gravid BMI < 25) and 10 overweight/obese (OB, pre-gravid BMI =25) women without gestational diabetes wer...

  18. Influence of the measurement location on the resistance index in the umbilical arteries: a hemodynamic approach.

    PubMed

    Vieyres, P; Durand, A; Patat, F; Descamps, P; Gregoire, J M; Pourcelot, D; Pourcelot, L

    1991-12-01

    A computer model was used to study the primary factors generating the reduction in resistance index, (S-D)/S, values observed by ultrasonic Doppler measurements in the umbilical artery, from the fetal insertion to the placental insertion (S represents the amplitude of the systolic peak and D the amplitude of the diastolic peak). This hemodynamic approach shows that the placental resistance is the primary factor, the viscosity and the cord length playing secondary roles. Clinically, the position of the measurement along the cord is an important factor. To increase the sensitivity of the index, the Doppler measurement must be performed near the fetal insertion, whereas a measurement near the placental insertion will make the Doppler examination more specific.

  19. Umbilical hernias: the cost of waiting.

    PubMed

    Strosberg, David S; Pittman, Matthew; Mikami, Dean

    2017-02-01

    Umbilical hernias are well described in the literature, but its impact on health care is less understood. The purpose of this study was to investigate the effect of non-operative management of umbilical hernias on cost, work absenteeism, and resource utilization. The Truven Health Database, consisting of 279 employers and over 3000 hospitals, was reviewed for all umbilical hernia patients, aged 18-64 who were enrolled in health plans for 12 months prior to surgery and 12 months after surgery. Patients were excluded if they had a recurrence or had been offered a "no surgery" approach within 1 year of the index date. The remaining patients were separated into surgery (open or laparoscopic repair) or no surgery (NS). Post-cost analysis at 90 and 365 days and estimated days off from work were reviewed for each group. The non-surgery cohort had a higher proportion of females and comorbidity index. Adjusted analysis showed significantly higher 90 and 365 costs for the surgery group (p < 0.0001), though the cost difference did decrease over time. NS group had significantly higher estimated days of health-care utilization at both the 90 (1.99 vs. 3.58 p < 0.0001) and 365 (8.69 vs. 11.04 p < 0.0001) day post-index mark. A subgroup analysis demonstrated laparoscopic repair had higher costs compared to open primarily due to higher index procedure costs (p < 0.05). Though the financial costs were found to be higher in the surgery group, the majority of these were due to the surgery itself. Significantly higher days of health-care utilization and estimated days off work were experienced in the NS group. It is our belief that early operative intervention will lead to decreased costs and resource utilization.

  20. Multivariable analysis of tests for the diagnosis of intrauterine growth restriction.

    PubMed

    Bachmann, L M; Khan, K S; Ogah, J; Owen, P

    2003-04-01

    To describe how data from antenatal fetal ultrasound biometry, amniotic fluid index and umbilical artery Doppler can be appropriately combined using multivariable models and to investigate how the addition of these ultrasound parameters influences the ability to predict intrauterine growth restriction (IUGR). This was a prospective cohort study involving 274 low-risk pregnancies undergoing serial ultrasound examination at predetermined intervals. Standard deviation (Z) scores of the last values for fetal abdominal area (FAA), growth velocity of the FAA, amniotic fluid index (AFI) and umbilical artery Doppler pulsatility index prior to delivery were calculated for 260 fetuses. Customized estimated fetal weight (cEFW) centiles were also calculated using the last EFW before delivery after adjustment for fetal gender, gestational age, birth order and maternal weight, height and ethnic origin. Following delivery the neonatal ponderal index was calculated and centile position obtained. A neonatal ponderal index <25(th) centile served as the main outcome measure for diagnosis of IUGR. Logistic regression analysis was used to delineate the predictive value of the three fetal growth tests FAA, FAA growth velocity and cEFW and the additional values of AFI and pulsatility index of the umbilical artery. The areas under the receiver-operating characteristics (ROC) curves (95% confidence interval) for FAA, FAA growth velocity and cEFW alone were 0.819 (0.748-0.891), 0.784 (0.699-0.869) and 0.74 (0.643-0.837), respectively, in the prediction of a neonatal ponderal index <25(th) centile. The addition of both the AFI and pulsatility index to FAA, FAA growth velocity and cEFW generated small increases in the areas, to 0.831 (0.758-0.904), 0.817 (0.735-0.899) and 0.766 (0.672-0.859), respectively. These improvements in diagnostic prediction were not statistically significant. The addition of AFI and umbilical artery pulsatility index to the fetal biometry parameters did not significantly increase the ROC areas in the study population. The approach applied in this study is useful in the context of hypothesis generation. Further studies using larger data sets and other predictors should be carried out using the analytical techniques outlined in this paper to determine the contribution of various antenatal tests in the prediction of IUGR. Copyright 2003 ISUOG. Published by John Wiley & Sons, Ltd.

  1. Construction and Test Results of Coils 2 and 3 of a 3-Nested-Coil 800-MHz REBCO Insert for the MIT 1.3-GHz LTS/HTS NMR Magnet.

    PubMed

    Park, Dongkeun; Bascuñán, Juan; Michael, Philip C; Lee, Jiho; Hahn, Seungyong; Iwasa, Yukikazu

    2018-04-01

    We present construction and test results of Coils 2 and 3 of a 3-coil 800-MHz REBCO insert (H800) for the MIT 1.3 GHz LTS/HTS NMR magnet currently under construction. Each of three H800 coils (Coils 1-3) is a stack of no-insulation REBCO double pancakes (DPs). The innermost 8.67-T Coil 1 (26 DPs) was completed in 2016; the middle 5.64-T Coil 2 (32 DPs) has been wound, assembled, and tested; and for the outermost 4.44-T Coil 3, its 38 DPs have been wound and preliminary tests were performed to characterize each DP at 77 K. Included for Coil 2 are: 1) 77-K data of critical current, index, and turn-to-turn characteristic resistivity of each DP; 2) stacking order of the 32 DPs optimized to maximize the Coil 2 current margin and minimize its Joule dissipation in the pancake-to-pancake joints; 3) procedure to experimentally determine and apply a room-temperature preload to the DP stack; 4) 77-K and 4.2-K test results after each of 64 pancakes was over-banded with 75-μm-thick stainless steel tape for a radial thickness of 5 mm. Presented for each DP in Coil 3 are 77-K dada of critical current, index, and turn-to-turn characteristic resistivity.

  2. Placental vascular dysfunction, fetal and childhood growth, and cardiovascular development: the generation R study.

    PubMed

    Gaillard, Romy; Steegers, Eric A P; Tiemeier, Henning; Hofman, Albert; Jaddoe, Vincent W V

    2013-11-12

    Suboptimal fetal nutrition may influence early growth and cardiovascular development. We examined whether umbilical and uterine artery resistance indices, as measures of feto-placental and utero-placental vascular function, respectively, are associated with fetal and childhood growth and cardiovascular development. This study was embedded in a population-based prospective cohort study among 6716 mothers and their children. Umbilical artery pulsatility index and uterine artery resistance index and fetal growth were measured in third trimester. Childhood growth was repeatedly assessed from birth to the age of 6 years. We measured body fat distribution, left ventricular mass, and blood pressure at the age of 6 years. Higher third trimester umbilical and uterine artery vascular resistance were associated with lower fetal length and weight growth in third trimester resulting in a smaller size at birth among boys and girls (P values < 0.05). These differences in length and weight growth became smaller from the age of 6 months onwards, but were still present at the age of 6 years. Higher third trimester umbilical artery vascular resistance, but not uterine artery vascular resistance, was associated with higher childhood body mass index, total fat mass, android/gynoid fat mass ratio, and systolic blood pressure, and with a lower left ventricular mass (P values<0.05). These associations were not explained by birth weight. Stronger associations tended to be present among girls as compared with boys. Higher third trimester feto-placental vascular resistance, but not utero-placental vascular resistance, was associated with slower fetal growth rates and cardiovascular adaptations in childhood.

  3. Concomitant Abdominoplasty and Laparoscopic Umbilical Hernia Repair.

    PubMed

    van Schalkwyk, Constant P; Dusseldorp, Joseph R; Liang, Derek G; Keshava, Anil; Gilmore, Andrew J; Merten, Steve

    2018-04-20

    Umbilical hernia is a common finding in patients undergoing abdominoplasty, especially those who are post-partum with rectus divarication. Concurrent surgical treatment of the umbilical hernia at abdominoplasty presents a "vascular challenge" due to the disruption of dermal blood supply to the umbilicus, leaving the stalk as the sole axis of perfusion. To date, there have been no surgical techniques described to adequately address large umbilical herniae during abdominoplasty. To present an effective and safe technique that can address large umbilical herniae during abdominoplasty. A prospective series of 10 consecutive patients, undergoing concurrent abdominoplasty and laparoscopic umbilical hernia repair between 2014 and 2017 were included in the study. All procedures were performed by the same general surgeon and plastic surgeon at the Macquarie University Hospital in North Ryde, NSW, Australia. Data was collected with approval of our ethics committee. At 12-month follow-up there were no instances of umbilical necrosis, wound complications, seroma or recurrent hernia. The mean body mass index was 23.8 kg/m2 (range, 16.1-30.1 kg/m2). Rectus divarication ranged from 35-80 mm (mean, 53.5 mm). Umbilical hernia repair took a mean of 25.9 minutes to complete (range, 18-35 minutes). We present a technique that avoids incision of the rectus fascia minimizes dissection of the umbilical stalk and is able to provide a gold standard hernia repair with mesh. This procedure is particularly suited to post-partum patients with large herniae (>3-4 cm diameter) and wide rectus divarication, where mesh repair with adequate overlap is the recommended treatment.

  4. Investigating a Quadrant Surface Coil Array for NQR Remote Sensing

    DTIC Science & Technology

    2014-10-23

    UNCLASSIFIED 1  Abstract—this paper is on the design and fabrication of a surface coil array in a quadrant layout for NQR (Nuclear Quadrupole...coupling and SNR (Signal-to-Noise Ratio) at standoff distances perpendicular from each coil. Index Terms— Nuclear Quadrupole Resonance, NQR ...Coil Array, probe, Nuclear Magnetic Resonance, tuning, decoupling, RLC, mutual coupling, RLC I. INTRODUCTION N Nuclear quadrupole resonance ( NQR

  5. Long-term follow-up results of umbilical hernia repair.

    PubMed

    Venclauskas, Linas; Jokubauskas, Mantas; Zilinskas, Justas; Zviniene, Kristina; Kiudelis, Mindaugas

    2017-12-01

    Multiple suture techniques and various mesh repairs are used in open or laparoscopic umbilical hernia (UH) surgery. To compare long-term follow-up results of UH repair in different hernia surgery groups and to identify risk factors for UH recurrence. A retrospective analysis of 216 patients who underwent elective surgery for UH during a 10-year period was performed. The patients were divided into three groups according to surgery technique (suture, mesh and laparoscopic repair). Early and long-term follow-up results including hospital stay, postoperative general and wound complications, recurrence rate and postoperative patient complaints were reviewed. Risk factors for recurrence were also analyzed. One hundred and forty-six patients were operated on using suture repair, 52 using open mesh and 18 using laparoscopic repair technique. 77.8% of patients underwent long-term follow-up. The postoperative wound complication rate and long-term postoperative complaints were significantly higher in the open mesh repair group. The overall hernia recurrence rate was 13.1%. Only 2 (1.7%) patients with small hernias (< 2 cm) had a recurrence in the suture repair group. Logistic regression analysis showed that body mass index (BMI) > 30 kg/m 2 , diabetes and wound infection were independent risk factors for umbilical hernia recurrence. The overall umbilical hernia recurrence rate was 13.1%. Body mass index > 30 kg/m 2 , diabetes and wound infection were independent risk factors for UH recurrence. According to our study results, laparoscopic medium and large umbilical hernia repair has slight advantages over open mesh repair concerning early postoperative complications, long-term postoperative pain and recurrence.

  6. [Evaluation of neonatal prognosis using Doppler velocimeter in cases of a high risk fetus].

    PubMed

    Ferchiou-Cherif, M; Zhioua, F; Hafsia, S; Hamdoun, L; Jedoui, A; Slim, R; Meriah, S

    1993-01-01

    The authors describe the main characteristics of the Doppler method in the early diagnosis of chronic fetal distress, and report their personal results in the study of 51 high risk pregnancies. In their study the fetal doppler ultrasound findings were correlated with birth weight related to gestational age, and neonatal morbidity. The parameters established from the doppler ultrasound assessment were the placenta resistance (calculated from the formula of Pourcelot: R = S-D/S applied to the umbilical artery) and the cerebro-placental index, Rp/Rc, Rc being the index of cerebral arterial resistance. The diagnosis performance of the method appeared very good: the Rp index was found to be highly specific for hypotrophy (85,7%) and for neonatal morbidity (90%), the RCP index adding its own good sensitivity (85% for hypotrophy and 83,3% for neonatal morbidity). The authors conclude upon the interest to study simultaneously the fetal umbilical and cerebral arterial circulations. The pathological significance of the two indexes appears different so that they are to be complementary in the evaluation of fetal distress.

  7. [Long-term follow-up results after open small umbilical hernia repairs].

    PubMed

    Malý, O; Sotona, O

    2014-04-01

    Adult umbilical hernia is a common surgical condition in the fifth and sixth decade of life. Despite the high frequency of umbilical hernia repairs, disappointingly high recurrence rates after simple suture repairs are reported, amounting to 54%. In addition, it is reported that with the rising frequency of recurrences, the size of the hernial sac and gate gradually increases. Therefore we decided to find out the incidence of recurrences after operative repair of an umbilical hernia at our department. Patient data for this retrospective study focusing on the period between 2006 and 2010 were obtained from the electronic hospital database. Patients with umbilical hernia and the abdominal wall defect up to 3 cm who underwent primary elective procedure were included in the study. Patients with incisional hernias were excluded. All patients were contacted at least 3 years after operation to confirm the accuracy of data. A total of 127 patients were included in this study. In the abovementioned period, no mesh was used during primary surgery in any of the patients. Recurrence occurred in a total of 13.4% of patients. Approximately 40% of patients with the first recurrence were re-operated at our department, 30% of patients were re-operated in other hospitals and the rest have not sought medical attention in respect of the recurrence. Patients with recurrence did not differ from the others as regards age, body mass index or surgical site infection development. Due to the high recurrence rates after operative sutures of the umbilical hernias there is a need to thoroughly consider the potential risk factors such as the body mass index and the abdominal wall defect size. Therefore, it is recommended to use the mesh more widely during primary surgery, especially in obese patients with BMI over 30 and the wall defect size exceeding 3 cm. The question remains whether to use the mesh in all overweight patients and with wall defect smaller than 3 cm.

  8. Successful transcatheter closure of a large patent ductus venosus with the Amplatzer vascular plug II.

    PubMed

    Cho, Y K; Chang, N-K; Ma, J S

    2009-05-01

    Patent ductus venosus is a rare form of congenital portosystemic shunt from the fetal umbilical vein to the inferior vena cava. The reported surgical treatments include ligation, banding, and liver transplantation. In addition, transcatheter closure with a coil, stent, or original Amplatzer vascular plug (AVP) has been reported. The AVP II, a redesigned version of the original vascular plug with a finer more densely woven nitinol wire and a large diameter (up to 22 mm) is available. This reported case is the first successful occlusion of a large patent ductus venosus with the new AVP II.

  9. Doppler ultrasound evaluation in preeclampsia

    PubMed Central

    2013-01-01

    Background Worldwide preeclampsia (PE) is the leading cause of maternal death and affects 5 to 8% of pregnant women. PE is characterized by elevated blood pressure and proteinuria. Doppler Ultrasound (US) evaluation has been considered a useful method for prediction of PE; however, there is no complete data about the most frequently altered US parameters in the pathology. The aim of this study was to evaluate the uterine, umbilical, and the middle cerebral arteries using Doppler US parameters [resistance index (RI), pulsatility index (PI), notch (N), systolic peak (SP) and their combinations] in pregnant women, in order to make a global evaluation of hemodynamic repercussion caused by the established PE. Results A total of 102 pregnant Mexican women (65 PE women and 37 normotensive women) were recruited in a cases and controls study. Blood velocity waveforms from uterine, umbilical, and middle cerebral arteries, in pregnancies from 24 to 37 weeks of gestation were recorded by trans-abdominal examination with a Toshiba Ultrasound Power Vision 6000 SSA-370A, with a 3.5 MHz convex transducer. Abnormal general Doppler US profile showed a positive association with PE [odds ratio (OR) = 2.93, 95% confidence interval (CI) = 1.2 - 7.3, P = 0.021)], and a specificity and predictive positive value of 89.2% and 88.6%, respectively. Other parameters like N presence, RI and PI of umbilical artery, as well as the PI of middle cerebral artery, showed differences between groups (P values < 0.05). Conclusion General Doppler US result, as well as N from uterine vessel, RI from umbilical artery, and PI from umbilical and middle cerebral arteries in their individual form, may be considered as tools to determine hemodynamic repercussion caused by PE. PMID:24252303

  10. Long-term follow-up results of umbilical hernia repair

    PubMed Central

    Venclauskas, Linas; Zilinskas, Justas; Zviniene, Kristina; Kiudelis, Mindaugas

    2017-01-01

    Introduction Multiple suture techniques and various mesh repairs are used in open or laparoscopic umbilical hernia (UH) surgery. Aim To compare long-term follow-up results of UH repair in different hernia surgery groups and to identify risk factors for UH recurrence. Material and methods A retrospective analysis of 216 patients who underwent elective surgery for UH during a 10-year period was performed. The patients were divided into three groups according to surgery technique (suture, mesh and laparoscopic repair). Early and long-term follow-up results including hospital stay, postoperative general and wound complications, recurrence rate and postoperative patient complaints were reviewed. Risk factors for recurrence were also analyzed. Results One hundred and forty-six patients were operated on using suture repair, 52 using open mesh and 18 using laparoscopic repair technique. 77.8% of patients underwent long-term follow-up. The postoperative wound complication rate and long-term postoperative complaints were significantly higher in the open mesh repair group. The overall hernia recurrence rate was 13.1%. Only 2 (1.7%) patients with small hernias (< 2 cm) had a recurrence in the suture repair group. Logistic regression analysis showed that body mass index (BMI) > 30 kg/m2, diabetes and wound infection were independent risk factors for umbilical hernia recurrence. Conclusions The overall umbilical hernia recurrence rate was 13.1%. Body mass index > 30 kg/m2, diabetes and wound infection were independent risk factors for UH recurrence. According to our study results, laparoscopic medium and large umbilical hernia repair has slight advantages over open mesh repair concerning early postoperative complications, long-term postoperative pain and recurrence. PMID:29362649

  11. A new approach to umbilical hernia repair: the circular suture technique for defects less than 2 cm.

    PubMed

    Yıldız, Ihsan; Koca, Yavuz Savas

    2017-01-01

    Umbilical hernia, unlike other abdominal wall hernias, occurs when the umbilical ring opens and expands. Its' symptoms and complications show similarities with other hernias. Although there are various repair techniques, there is not a standard technique yet. This paper investigated the outcomes of double layer circular suture technique as a new approach in the repair of umbilical hernia. A total number of 282 patients comprised of 102 males and 180 females with an age range of 18-89 whose umbilical hernias were repaired between 2002 and 2013, retrospectively studied in two groups group 1 (circular suture technique) and group 2 (open primary suture). The subjects were investigated with regards to age, sex, body mass index (BMI), accompanying disease, anesthesia method, surgical complications, hospital stay, total costs, mortality and recurrence. The study participants were 282 patients with an age average of 49, 09 ± 16, 62 including 182 patients in group 1 (male/female ratio 76/106) and 100 patients in group 2 (26/74). There was a significant difference between the groups in terms of time and recurrence. During the follow-up period, 9 patients in group 1 (4.94%) and 16 patients in group 2 (16%) had a recurrence. This result was statistically significant (p=0.014) CONCLUSION: We believe that the double layer circular suture technique is practical, inexpensive and effective in the repair of umbilical hernia defects, which are smaller than 2 cm diameter. Key words: Hernia, Repair, Umbilical hernia.

  12. Laparoscopic management of urachal cyst associated with umbilical hernia.

    PubMed

    Gregory, G C; Vijay, R; Ligaj, M; Shiwani, M H

    2011-02-01

    The urachal cyst is a rare clinical entity of a urachal remnant. It is usually asymptomatic but can present with haematuria, tumour, urachal stone and infection. We present a case of a 63-year-old lady with a body mass index (BMI) of 49 who presented with a painful swelling in the umbilical region associated with an umbilical hernia. An ultrasound and computed tomography (CT) scan showed a suspected herniation of an umbilical remnant cyst through a paraumbilical defect. Laparoscopy confirmed the urachal cyst of 3 cm in size with a band connected with the cyst down to the urinary bladder associated with a 3-cm paraumbilical hernia. We removed the cyst and repaired the hernia laparoscopically uneventfully, after which her recovery was perfect. Radiological and laparoscopic pictures have not been reported in the English literature before. Although this condition is very rare, we suggest that it should be considered in the differential diagnosis of painful paraumbilical swelling. CT scanning and laparoscopy seems to be valuable, especially in obese patients.

  13. Programmable Mechanobioreactor for Exploration of the Effects of Periodic Vibratory Stimulus on Mesenchymal Stem Cell Differentiation

    PubMed Central

    Cashion, Avery T.; Caballero, Montserrat; Halevi, Alexandra; Pappa, Andrew; Dennis, Robert G.

    2014-01-01

    Abstract A programmable bioreactor using a voice-coil actuator was developed to enable research on the effects of periodic vibratory stimulus on human and porcine mesenchymal stem cells (MSCs). We hypothesized that low frequency vibrations would result in a cartilage phenotype and higher frequency vibrations would result in a bone phenotype. The mechanical stimulation protocol is adjusted from a computer external to the incubator via a USB cable. Once programmed, the embedded microprocessor and sensor system on the bioreactor execute the protocol independent of the computer. In each test, a sinusoidal stimulus was applied to a culture plate in 1-min intervals with a 15-min rest following each, for a total of 15 h per day for 10 days. Frequencies of 1 and 100 Hz were applied to cultures of both human and porcine umbilical cord–derived MSCs. Chondrogenesis was determined by Alcian blue staining for glycosaminoglycans and an increased differentiation index (ratio of mRNA for collagen II and collagen I). Osteogenic differentiation was indicated with Alizarin red for calcium staining and increased bone morphogenetic protein 2 mRNA. One-hertz stimulation resulted in a cartilage phenotype for both human and porcine MSCs, while 100-Hz stimulation resulted in a bone phenotype. PMID:24570842

  14. Evaluation of feline uterine and umbilical arteries blood flow in a pharmacologically induced abnormal gestation model.

    PubMed

    Blanco, P G; Vercellini, R; Rube, A; Rodríguez, R; Arias, D O; Gobello, C

    2016-12-01

    The aim of this study was to describe resistance index (RI) and systolic/diastolic ratio (S/D ratio) of uterine and umbilical arteries in an experimental model of abnormal pregnancy in felids. On days 30 to 35 (32 ± 2.9) after mating, 20 domestic short-hair pregnant queens were randomly assigned to one of the following treatment groups: a treated group (TG; n = 8), which received 10 mg/kg of aglepristone subcutaneously twice, 24 hours apart, and a control nontreated group (CG; n = 12). M-mode and Doppler ultrasonographic evaluations were performed at the initiation of the treatment (Day 0) and then every other day during 8 days. In both groups, uterine and umbilical arteries were evaluated by Doppler ultrasound, whereas fetal heart rate was assessed by M-mode ultrasound. Resistance index of uterine artery augmented in TG from Day 2 onward, conversely it decreased in CG (P < 0.01). On Day 8, RI values were 0.64 ± 0.05 vs 0.37 ± 0.01 for TG and CG, respectively. Additionally, S/D ratio of the same artery presented an increase in TG, whereas this ratio diminished in CG (P < 0.01). On Day 8, this parameter showed values of 2.98 ± 0.4 vs 1.62 ± 0.06 for TG and CG, respectively. Resistance index of umbilical artery remained almost unchanged in TG from Day 6 onward, whereas it progressively decreased in CG throughout the course of the study (P < 0.05). On Day 8, RI were 0.89 ± 0.04 and 0.82 ± 0.01, for TG and CG, respectively. Furthermore, on Day 8, S/D ratio of umbilical artery progressively diminished in CG but not in TG (P < 0.01), being 14.7 ± 9.1 vs 5.9 ± 0.3 for TG and CG, respectively. Fetal heart rate was higher in TG than in CG (P < 0.05). Group differences in Doppler parameters appeared on Day 2, when the other clinical or ultrasonographic signs were still absent. It is concluded that blood flow of the uterine and umbilical arteries differed between these normal and abnormal gestations predicting an adverse obstetric outcome. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Chronic hypoxia alters maternal uterine and fetal hemodynamics in the full-term pregnant guinea pig.

    PubMed

    Turan, Sifa; Aberdeen, Graham W; Thompson, Loren P

    2017-10-01

    Placental hypoxia is associated with maternal hypertension, placental insufficiency, and fetal growth restriction. In the pregnant guinea pig, prenatal hypoxia during early gestation inhibits cytotrophoblast invasion of spiral arteries, increases maternal blood pressure, and induces fetal growth restriction. In this study the impact of chronic maternal hypoxia on fetal heart structure was evaluated using four-dimensional echocardiography with spatiotemporal image correlation and tomographic ultrasound, and uterine and umbilical artery resistance/pulsatility indexes and fetal heart function were evaluated using pulsed-wave Doppler ultrasound. Pregnant guinea pigs were exposed to normoxia ( n = 7) or hypoxia (10.5% O 2 , n = 9) at 28-30 days gestation, which was maintained until full term (65 days). At full term, fetal heart structure and outflow tracts were evaluated in the four-chamber view. Fetal heart diastolic function was assessed by E wave-to-A wave diastolic filling ratios (E/A ratios) of both ventricles and systolic function by the myocardial performance index (or Tie) of left ventricles of normoxic ( n = 21) and hypoxic ( n = 17) fetuses. There were no structural abnormalities in fetal hearts. However, hypoxia induced asymmetric fetal growth restriction and increased the placental/fetal weight compared with normoxic controls. Hypoxia increased Doppler resistance and pulsatility indexes in the uterine, but not umbilical, arteries, had no effect on the Tie index, and increased the E/A ratio in left, but not right, ventricles. Thus, prolonged hypoxia, starting at midgestation, increases uterine artery resistance and generates fetal growth restriction at full term. Furthermore, the enhanced cardiac diastolic filling with no changes in systolic function or umbilical artery resistance suggests that the fetal guinea pig systemic circulation undergoes a compensated, adaptive response to prolonged hypoxia exposure. Copyright © 2017 the American Physiological Society.

  16. Comparison of human mesenchymal stromal cells from four neonatal tissues: Amniotic membrane, chorionic membrane, placental decidua and umbilical cord.

    PubMed

    Araújo, Anelise Bergmann; Salton, Gabrielle Dias; Furlan, Juliana Monteiro; Schneider, Natália; Angeli, Melissa Helena; Laureano, Álvaro Macedo; Silla, Lúcia; Passos, Eduardo Pandolfi; Paz, Ana Helena

    2017-05-01

    Mesenchymal stromal cells (MSCs) are being investigated as a potential alternative for cellular therapy. This study was designed to compare the biological characteristics of MSCs isolated from amniotic membrane (A-MSCs), chorionic membrane (C-MSCs), placental decidua (D-MSCs) and umbilical cord (UC-MSCs) to ascertain whether any one of these sources is superior to the others for cellular therapy purposes. MSCs were isolated from amniotic membrane, chorionic membrane, umbilical cord and placental decidua. Immunophenotype, differentiation ability, cell size, cell complexity, polarity index and growth kinetics of MSCs isolated from these four sources were analyzed. MSCs were successfully isolated from all four sources. Surface marker profile and differentiation ability were consistent with human MSCs. C-MSCs in suspension were the smallest cells, whereas UC-MSCs presented the greatest length and least width. A-MSCs had the lowest polarity index and UC-MSCs, as more elongated cells, the highest. C-MSCs, D-MSCs and UC-MSCs exhibited similar growth capacity until passage 8 (P8); C-MSCs presented better lifespan, whereas insignificant proliferation was observed in A-MSCs. Neonatal and maternal tissues can serve as sources of multipotent stem cells. Some characteristics of MSCs obtained from four neonatal tissues were compared and differences were observed. Amniotic membrane was the least useful source of MSCs, whereas chorionic membrane and umbilical cord were considered good options for future use in cell therapy because of the known advantages of immature cells. Copyright © 2017 International Society for Cellular Therapy. Published by Elsevier Inc. All rights reserved.

  17. Early functional and morphological brain disturbances in late-onset intrauterine growth restriction.

    PubMed

    Starčević, Mirta; Predojević, Maja; Butorac, Dražan; Tumbri, Jasna; Konjevoda, Paško; Kadić, Aida Salihagić

    2016-02-01

    To determine whether the brain disturbances develop in late-onset intrauterine growth restriction (IUGR) before blood flow redistribution towards the fetal brain (detected by Doppler measurements in the middle cerebral artery and umbilical artery). Further, to evaluate predictive values of Doppler arterial indices and umbilical cord blood gases and pH for early functional and/or morphological brain disturbances in late-onset IUGR. This cohort study included 60 singleton term pregnancies with placental insufficiency caused late-onset IUGR (IUGR occurring after 34 gestational weeks). Umbilical artery resistance index (URI), middle cerebral artery resistance index (CRI), and cerebroumbilical (C/U) ratio (CRI/URI) were monitored once weekly. Umbilical blood cord samples (arterial and venous) were collected for the analysis of pO2, pCO2 and pH. Morphological neurological outcome was evaluated by cranial ultrasound (cUS), whereas functional neurological outcome by Amiel-Tison Neurological Assessment at Term (ATNAT). 50 fetuses had C/U ratio>1, and 10 had C/U ratio≤1; among these 10 fetuses, 9 had abnormal neonatal cUS findings and all 10 had non-optimal ATNAT. However, the total number of abnormal neurological findings was much higher. 32 neonates had abnormal cUS (53.37%), and 42 (70.00%) had non-optimal ATNAT. Furthermore, Doppler indices had higher predictive validity for early brain disturbances than umbilical cord blood gases and pH. C/U ratio had the highest predictive validity with threshold for adverse neurological outcome at value 1.13 (ROC analysis), i.e., 1.18 (party machine learning algorithm). Adverse neurological outcome at average values of C/U ratios>1 confirmed that early functional and/or structural brain disturbances in late-onset IUGR develop even before activation of fetal cardiovascular compensatory mechanisms, i.e., before Doppler signs of blood flow redistribution between the fetal brain and the placenta. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  18. A comparison of the effects of the most commonly used tocolytic agents on maternal and fetal blood flow

    PubMed Central

    Güden, Mahmut; Akkurt, Mehmet Özgür; Eriş Yalçın, Serenat; Coşkun, Bora; Akkurt, Iltaç; Yavuz, And; Yirci, Bülent; Kandemir, Necmi Ömer

    2016-01-01

    Objective: To investigate the effects of two tocolytics, nifedipine and magnesium sulfate, on Doppler indices in maternal and fetal vessels. Materials and Methods: We recruited 100 pregnant women with preterm birth between 24-36 gestational weeks who were admitted to our tertiary center over a two-year period. Patients were allocated to nifedipine (n=49) and magnesium sulfate (n=51) groups and Doppler indices of umbilical, middle cerebral, uterine arteries, and ductus venosus were measured before and after tocolysis. Results: There were no differences between the groups in terms of maternal age, gestational week, body mass indexes, cervical dilation, effacement at admission, birth weights and latency periods until birth. Nifedipine decreased resistance indexes in uterine arteries but magnesium sulfate increased resistance especially in the right uterine artery. Nifedipine significantly decreased systole to diastole and resistance index in the umbilical artery, magnesium sulfate increased systole to diastole and resistance index but this was not statistically significant. Nifedipine acted variably on resistance index and pulsatility index in the ductus venosus; however, magnesium sulfate increased resistance. Nifedipine decreased pulsatility index in the middle cerebral artery, contrary to magnesium sulfate with which it increased. Conclusion: Nifedipine had favorable effects on maternal and fetal vessel indexes but magnesium sulfate increased resistance. Despite the proposed neuroprotective benefits of magnesium sulfate, nifedipine seems to be a better and safer tocolytic agent than magnesium sulfate due to its positive beneficial effects on maternal and fetal vessels. PMID:28913098

  19. Perfluoroalkyl acids (PFAAs) and anthropometric measures in the first year of life: Results from the Duisburg Birth Cohort.

    PubMed

    Alkhalawi, Eman; Kasper-Sonnenberg, Monika; Wilhelm, Michael; Völkel, Wolfgang; Wittsiepe, Jürgen

    2016-01-01

    In the context of the Duisburg Birth Cohort, this retrospective cohort study provides results of internal exposure to perfluorooctanoic acid (PFOA), perfluorooctanesulfonic acid (PFOS), and perfluorohexanesulfonic acid (PFHxS) in 156 mother-child pairs, and investigates whether and to what extent in utero exposure of these chemicals at German background levels exerts an effect on newborn and infant weight and length, and weight in relation to length expressed by ponderal index, in order to examine whether any reduction in weight is disproportionate to length. The levels of PFOA, PFOS, and PFHxS were determined in 81 maternal and 83 umbilical cord stored frozen plasma samples and 105 umbilical cord blood samples. Calculated factors were used to convert umbilical cord values to maternal levels. Weights and lengths were retrieved at birth and at 1, 4, 6, and 12 mo from examination booklets and ponderal index (kg/m 3 ) was calculated. Subsequently, correlations were assessed using multiple linear regressions and generalized estimation equations with each of the measures as a continuous outcome variable and with PFOA, PFOS, and PFHxS concentration quartiles as categorized predictor variables, while adjusting for relevant covariates. PFOA, PFOS, and PFHxS were generally within German background exposure levels. There was a significant association between PFOA, PFOS, and PFHxS concentration quartiles and decrease in ponderal index at birth but not weight or height. A nonsignificant negative association between exposure to all three compounds and birth weight was noted. Follow-up showed no sustained effect of the PFAA on anthropometric measures during the first year.

  20. Proteomic evaluation of human umbilical cord tissue exposed to polybrominated diphenyl ethers in an e-waste recycling area.

    PubMed

    Li, Minghui; Huo, Xia; Pan, Yukui; Cai, Haoxing; Dai, Yifeng; Xu, Xijin

    2018-02-01

    Parental exposure to polybrominated diphenyl ethers (PBDEs) is associated with adverse birth outcomes. This study aims to examine differentially-expressed protein profiles in umbilical cord tissue, derived from mothers exposed to PBDEs, and investigate candidate biomarkers to reveal the underlying molecular mechanisms. Umbilical cord samples were obtained from women residing in an electronic waste (e-waste) recycling area (Guiyu) and reference area (Haojiang) in China. The concentration of PBDEs in umbilical cord tissue was determined by gas chromatography and mass spectrometry (GC/MS). Isobaric tagging for relative and absolute quantification (iTRAQ)-based proteomic technology was conducted to analyze differentially-expressed protein profiles. The total PBDE concentration was approximately five-fold higher in umbilical cords from Guiyu than from Haojiang (median 71.92ng/g vs. 15.52ng/g lipid, P<0.01). Neonatal head circumference, body-mass index (BMI) and Apgar1 score were lower in Guiyu and negatively correlated with PBDE concentration (P<0.01). Proteomic analysis showed 697 proteins were differentially expressed in the e-waste-exposed group compared with the reference group. The differentially-expressed proteins were principally involved in antioxidant defense, apoptosis, cell structure and metabolism. Among them, catalase and glutathione S-transferase omega-1, were down-regulated, and cytochrome c was found to be up-regulated, changes which were further verified by enzyme-linked immunosorbent assays. These results suggest that an antioxidant imbalance and cell apoptosis in the umbilical cord following PBDE exposure is associated with neonatal birth outcomes. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. A highly versatile adaptor protein for the tethering of growth factors to gelatin-based biomaterials.

    PubMed

    Addi, Cyril; Murschel, Frédéric; Liberelle, Benoît; Riahi, Nesrine; De Crescenzo, Gregory

    2017-03-01

    In the field of tissue engineering, the tethering of growth factors to tissue scaffolds in an oriented manner can enhance their activity and increase their half-life. We chose to investigate the capture of the basic Fibroblast Growth Factor (bFGF) and the Epidermal Growth Factor (EGF) on a gelatin layer, as a model for the functionalization of collagen-based biomaterials. Our strategy relies on the use of two high affinity interactions, that is, the one between two distinct coil peptides as well as the one occurring between a collagen-binding domain (CBD) and gelatin. We expressed a chimeric protein to be used as an adaptor that comprises one of the coil peptides and a CBD derived from the human fibronectin. We proved that it has the ability to bind simultaneously to a gelatin substrate and to form a heterodimeric coiled-coil domain with recombinant growth factors being tagged with the complementary coil peptide. The tethering of the growth factors was characterized by ELISA and surface plasmon resonance-based biosensing. The bioactivity of the immobilized bFGF and EGF was evaluated by a human umbilical vein endothelial cell proliferation assay and a vascular smooth muscle cell survival assay. We found that the tethering of EGF preserved its mitogenic and anti-apoptotic activity. In the case of bFGF, when captured via our adaptor protein, changes in its natural mode of interaction with gelatin were observed. In an effort to functionalize collagen/gelatin-based biomaterials with growth factors, we have designed an adaptor protein corresponding to a collagen-binding domain fused to a coil peptide. In our strategy, this adaptor protein captures growth factors being tagged with the partner coil peptide in a specific, stable and oriented manner. We have found that the tethering of the Epidermal Growth Factor preserved its mitogenic and anti-apoptotic activity. In the case of the basic Fibroblast Growth Factor, the captured growth factor remained bioactive although its tethering via this adaptor protein modified its natural mode of interaction with gelatin. Altogether this strategy is easily adaptable to the simultaneous tethering of various growth factors. Copyright © 2017 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  2. Aneurysm coil embolization: cost per volumetric filling analysis and strategy for cost reduction.

    PubMed

    Wang, Charlie; Ching, Esteban Cheng; Hui, Ferdinand K

    2016-05-01

    One of the primary device expenditures associated with the endovascular treatment of aneurysms is that of detachable coils. Analyzing the cost efficiency of detachable coils is difficult, given the differences in design, implantable volume, and the presence of additives. However, applying a volume per cost metric may provide an index analogous to unit price found in grocery stores. The price information for 509 different coils belonging to 31 different coil lines, available as of September 2013, was obtained through the inventory management system at the study site, and normalized to the price of the least expensive coil. Values were used to calculate the logarithmic ratio of volume over cost. Operator choice among coil sizes can vary the material costs by five-fold in a hypothetical aneurysm. The difference in coil costs as a function of cost per volume of coil can vary tremendously. Using the present pricing algorithms, using the longest available length at a particular helical dimension and system yields improved efficiency. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  3. The risk of umbilical hernia and other complications with laparoendoscopic single-site surgery.

    PubMed

    Gunderson, Camille C; Knight, Jason; Ybanez-Morano, Jessica; Ritter, Carol; Escobar, Pedro F; Ibeanu, Okechukwu; Grumbine, Francis C; Bedaiwy, Mohamed A; Hurd, William W; Fader, Amanda Nickles

    2012-01-01

    To estimate the risk of umbilical hernia and other latent complications in women who underwent laparoendoscopic single-site surgery (LESS) for a gynecologic indication. Retrospective, nonrandomized clinical study (Canadian Task Force classification II-2). Four tertiary care academic medical centers. Women undergoing LESS for a benign or malignant gynecologic indication from 2009 to 2011. A total of 211 women underwent LESS via a single 1.5- to 2.0-cm umbilical incision. All surgeries were performed by advanced gynecologic laparoscopists. Incisions were repaired with a running, delayed absorbable suture. Subject demographics and clinical variables were collected and surgical outcomes analyzed. Median age and body mass index were 45 years and 30 kg/m(2), respectively. Approximately half of study subjects underwent a hysterectomy with or without salpingo-oophorectomy, and 15% had a diagnosis of cancer. Overall, 0.9% of women were diagnosed with a preoperative umbilical hernia, and 2.4% of women experienced a major perioperative complication. After a median postoperative follow-up time of 16 months, 2.4% had development of an umbilical hernia. However, 4/5 of these women had significant risk factors for fascial weakening independent of LESS, including requirement for a second abdominal surgery in 1 subject and a cancer diagnosis with postoperative chemotherapy administration in 2 subjects. When these subjects deemed "high risk" for incisional disruption were excluded from the analysis, the umbilical hernia rate was 0.5% (1/207). On univariable analysis, obesity was the only factor associated with complications (p = .04). When performed by advanced laparoscopic surgeons, laparoendoscopic single-site gynecologic surgery is associated with a low risk of major adverse events. Additionally, the overall umbilical hernia rate was 2.4% and was lower (0.5%) in subjects without significant comorbidities. Copyright © 2012 AAGL. Published by Elsevier Inc. All rights reserved.

  4. Heat Treatment Optimization of Rutherford Cables for a 15 T Nb 3Sn Dipole Demonstrator

    DOE PAGES

    Barzi, Emanuela; Bossert, Marianne; Field, Michael; ...

    2017-01-09

    FNAL has been developing a 15 T Nb 3Sn dipole demonstrator for a future Very High Energy pp Collider based on an optimized 60-mm aperture 4-layer “cos-theta” coil. In order to increase magnet efficiency, we graded the coil by using two cables with same 15 mm width and different thicknesses made of two different Restacked Rod Process (RRP®) wires. Due to the non-uniform field distribution in dipole coils the maximum field in the inner coil will reach 15-16 T, whereas the maximum field in the outer coil is 12-13 T. In preparation for the 15 T dipole coil reaction, heatmore » treatment studies were performed on strands extracted from these cables with the goal of achieving the best coil performance in the corresponding magnetic fields. Particularly, the effect of maximum temperature and time on the cable critical current was studied to take into account actual variations of these parameters during coil reaction. In parallel and in collaboration with OST, development was performed on optimizing Nb 3Sn RRP® wire design and layout. Index Terms— Accelerator magnet, critical current density, Nb 3Sn strand, Rutherford cable.« less

  5. Design Optimization for a Maglev System Employing Flux Eliminating Coils

    NASA Technical Reports Server (NTRS)

    Davey, Kent R.

    1996-01-01

    Flux eliminating coils have received no little attention over the past thirty years as an alternative for realizing lift in a MAGLEV system. When the magnets on board the vehicle are displaced from the equilibrium or null flux point of these coils, they induce current in those coils which act to restore the coil to its null flux or centerline position. The question being addressed in this paper is that of how to choose the best coil for a given system. What appears at first glance to be an innocent question is in fact one that is actually quite involved, encompassing both the global economics and physics of the system. The real key in analyzing that question is to derive an optimization index or functional which represents the cost of the system subject to constraints, the primary constraint being that the vehicle lift itself at a certain threshold speed. Outlined in this paper is one scenario for realizing a total system design which uses sequential quadratic programming techniques.

  6. Coil occlusion of residual shunts after surgical closure of patent ductus arteriosus.

    PubMed

    Fujii, Yoko; Keene, Bruce W; Mathews, Kyle G; Atkins, Clarke E; Defrancesco, Teresa C; Hardie, Elizabeth M; Wakao, Yoshito

    2006-12-01

    OBJECTIVE; To describe use of coil embolization to occlude residual flow through a patent ductus arteriosus (PDA) after incomplete surgical ligation. Clinical study. Dogs (n=4) with continuous murmur after surgical ligation of PDA. After PDA ligation, residual ductal flow through the PDA was visible on color-flow Doppler examination and left ventricular end-diastolic diameter remained increased. Coil embolization by an arterial approach was performed to achieve complete occlusion of the PDA. Embolization coils were delivered without complications and hemodynamically successful occlusion was achieved. Doppler-visible flow resolved in 2 dogs within 3 months after embolization. Left ventricular end-diastolic diameter indexed to body weight decreased in all dogs. Transcatheter coil embolization appears to be a safe and minimally invasive procedure for complete occlusion of residual PDA flow after incomplete surgical ligation. Transcatheter coil embolization should be considered for correction of hemodynamically significant residual shunts in dogs that have incomplete PDA occlusion after open surgical ligation.

  7. Concurrent Umbilical Hernia Repair at the Time of Liver Transplantation: A Six-Year Experience from a Single Institution

    PubMed Central

    Perez, A. J.; Haskins, I. N.; Prabhu, A. S.; Krpata, D. M.; Tu, C.; Rosenblatt, S.; Hashimoto, K.; Diago, T.; Eghtesad, B.; Rosen, M. l. J.

    2018-01-01

    Background: Umbilical hernias are common in patients with end-stage liver disease undergoing liver transplantation. Management of those persisting at the time of liver transplantation is important to define. Objective: To evaluate the long-term results of patients undergoing simultaneous primary umbilical hernia repair (UHR) at the time of liver transplantation at a single institution. Methods: Retrospective chart review was performed on patients undergoing simultaneous UHR and liver transplantation from 2010 through 2016. 30-day morbidity and mortality outcomes and long-term hernia recurrence were investigated. Results: 59 patients had primary UHR at the time of liver transplantation. All hernias were reducible with no overlying skin breakdown or leakage of ascites. 30-day morbidity and mortality included 5 (8%) superficial surgical site infections, 1 (2%) deep surgical site infection, and 7 (12%) organ space infections. Unrelated to the UHR, 10 (17%) patients had an unplanned return to the operating room, 16 (27%) were readmitted within 30 days of their index operation, and 1 (2%) patient died. With a mean follow-up of 21.8 months, 7 (18%) patients experienced an umbilical hernia recurrence. Conclusion: Despite the high perioperative morbidity associated with the transplant procedure, concurrent primary UHR resulted in an acceptable long-term recurrence rate with minimal associated morbidity. PMID:29531643

  8. Concurrent Umbilical Hernia Repair at the Time of Liver Transplantation: A Six-Year Experience from a Single Institution.

    PubMed

    Perez, A J; Haskins, I N; Prabhu, A S; Krpata, D M; Tu, C; Rosenblatt, S; Hashimoto, K; Diago, T; Eghtesad, B; Rosen, M L J

    2018-01-01

    Umbilical hernias are common in patients with end-stage liver disease undergoing liver transplantation. Management of those persisting at the time of liver transplantation is important to define. To evaluate the long-term results of patients undergoing simultaneous primary umbilical hernia repair (UHR) at the time of liver transplantation at a single institution. Retrospective chart review was performed on patients undergoing simultaneous UHR and liver transplantation from 2010 through 2016. 30-day morbidity and mortality outcomes and long-term hernia recurrence were investigated. 59 patients had primary UHR at the time of liver transplantation. All hernias were reducible with no overlying skin breakdown or leakage of ascites. 30-day morbidity and mortality included 5 (8%) superficial surgical site infections, 1 (2%) deep surgical site infection, and 7 (12%) organ space infections. Unrelated to the UHR, 10 (17%) patients had an unplanned return to the operating room, 16 (27%) were readmitted within 30 days of their index operation, and 1 (2%) patient died. With a mean follow-up of 21.8 months, 7 (18%) patients experienced an umbilical hernia recurrence. Despite the high perioperative morbidity associated with the transplant procedure, concurrent primary UHR resulted in an acceptable long-term recurrence rate with minimal associated morbidity.

  9. Neonatal liver abscesses due to Candida infection in a preterm infant, secondary to malpositioned umbilical lines – a rare entity

    PubMed Central

    Sharma, Deepak; Choudhary, Mukesh; Shastri, Sweta; Sharma, Pradeep Kumar

    2015-01-01

    Neonatal liver abscess is an uncommon seen condition in neonatology and it holds a very high neonatal mortality because of difficulty in diagnosis and treatment. Till today, only few instances are reported that too are mainly in preterm. Its diagnosis requires a high index of suspicion. Fungal hepatic abscess is very rare and in medical literature very few case reports are there in the medical literature. Here, we report a case of Candida albicans liver abscess in a preterm neonate, secondary to malpositioned umbilical lines that presented with respiratory difficulty and other clinical features of sepsis that was managed medically and discharged successfully. PMID:25736870

  10. Factors Associated With Long-term Outcomes of Umbilical Hernia Repair.

    PubMed

    Shankar, Divya A; Itani, Kamal M F; O'Brien, William J; Sanchez, Vivian M

    2017-05-01

    Umbilical hernia repair is one of the most commonly performed general surgical procedures. However, there is little consensus about the factors that lead to umbilical hernia recurrence. To better understand the factors associated with long-term umbilical hernia recurrence. A retrospective cohort of 332 military veteran patients who underwent umbilical hernia repair was studied between January 1, 1998, and December 31, 2008, at the VA Boston Healthcare System. Recurrence and mortality outcomes were tracked from that period until June 1, 2014. Data were collected on patient characteristics, operative, and postoperative factors and univariate and multivariable analyses were used to assess which factors were significantly associated with umbilical hernia recurrence and mortality. All patients with primary umbilical hernia repair, with or without a concurrent unrelated procedure, were included in the study. Patients excluded were those who underwent umbilical hernia repair as a part of another major planned procedure with abdominal incisions. Data were collected from June 1, 2014, to November 1, 2015. Statistical analysis was performed from November 2, 2015, to April 1, 2016. The primary study outcomes were umbilical hernia recurrence and death. Of the 332 patients in this study, 321 (96.7%) were male, mean age was 58.4 years, and mean (SD) time of follow-up was 8.5 (4.1) years. The hernia recurrence rate was 6.0% (n = 20) at a mean 3.1 years after index repair (median, 1.0-year; range, 0.33-13 years). The primary suture repair recurrence rate was 9.8% (16 of 163 patients), and the mesh repair recurrence rate was 2.4% (4 of 169 patients). On univariate analysis, ascites (P = .02), liver disease (P = .02), diabetes (P = .04), and primary suture (nonmesh) repairs (P = .04) were significantly associated with increased recurrence rates. Patients who had a history of hernias (125 [39%]) were less likely to have umbilical hernia recurrences (χ21 = 4.65, P = .03). On multivariable regression analysis, obesity and ascites were associated with significantly increased odds ratios of recurrence of 3.3 (95% CI, 1.0-10.1) and 8.0 (95% CI, 1.8-34.4), respectively. Mesh repair was seen to decrease recurrence with odds of 0.28 (95% CI, 0.08-0.95). There was no significant difference in complication rates between mesh repair and primary suture repair. The survival rate was 73% (n = 242) at the end of the study. Factors associated with mortality were older age, smoking, liver disease, ascites, emergency or semiurgent repair, and need for intraoperative bowel resection. Ascites, liver disease, diabetes, obesity, and primary suture repair without mesh are associated with increased umbilical hernia recurrence rates. Elective umbilical hernia repair with mesh should be considered in patients with multiple comorbidities given that the use of mesh offers protection from recurrence without major morbidity.

  11. Factors Associated With Long-term Outcomes of Umbilical Hernia Repair

    PubMed Central

    Shankar, Divya A.; Itani, Kamal M. F.; O’Brien, William J.

    2017-01-01

    Importance Umbilical hernia repair is one of the most commonly performed general surgical procedures. However, there is little consensus about the factors that lead to umbilical hernia recurrence. Objective To better understand the factors associated with long-term umbilical hernia recurrence. Design, Setting, and Participants A retrospective cohort of 332 military veteran patients who underwent umbilical hernia repair was studied between January 1, 1998, and December 31, 2008, at the VA Boston Healthcare System. Recurrence and mortality outcomes were tracked from that period until June 1, 2014. Data were collected on patient characteristics, operative, and postoperative factors and univariate and multivariable analyses were used to assess which factors were significantly associated with umbilical hernia recurrence and mortality. All patients with primary umbilical hernia repair, with or without a concurrent unrelated procedure, were included in the study. Patients excluded were those who underwent umbilical hernia repair as a part of another major planned procedure with abdominal incisions. Data were collected from June 1, 2014, to November 1, 2015. Statistical analysis was performed from November 2, 2015, to April 1, 2016. Main Outcomes and Measures The primary study outcomes were umbilical hernia recurrence and death. Results Of the 332 patients in this study, 321 (96.7%) were male, mean age was 58.4 years, and mean (SD) time of follow-up was 8.5 (4.1) years. The hernia recurrence rate was 6.0% (n = 20) at a mean 3.1 years after index repair (median, 1.0-year; range, 0.33-13 years). The primary suture repair recurrence rate was 9.8% (16 of 163 patients), and the mesh repair recurrence rate was 2.4% (4 of 169 patients). On univariate analysis, ascites (P = .02), liver disease (P = .02), diabetes (P = .04), and primary suture (nonmesh) repairs (P = .04) were significantly associated with increased recurrence rates. Patients who had a history of hernias (125 [39%]) were less likely to have umbilical hernia recurrences (χ21 = 4.65, P = .03). On multivariable regression analysis, obesity and ascites were associated with significantly increased odds ratios of recurrence of 3.3 (95% CI, 1.0-10.1) and 8.0 (95% CI, 1.8-34.4), respectively. Mesh repair was seen to decrease recurrence with odds of 0.28 (95% CI, 0.08-0.95). There was no significant difference in complication rates between mesh repair and primary suture repair. The survival rate was 73% (n = 242) at the end of the study. Factors associated with mortality were older age, smoking, liver disease, ascites, emergency or semiurgent repair, and need for intraoperative bowel resection. Conclusions and Relevance Ascites, liver disease, diabetes, obesity, and primary suture repair without mesh are associated with increased umbilical hernia recurrence rates. Elective umbilical hernia repair with mesh should be considered in patients with multiple comorbidities given that the use of mesh offers protection from recurrence without major morbidity. PMID:28122076

  12. Shape memory polymer (SMP) gripper with a release sensing system

    DOEpatents

    Maitland, Duncan J.; Lee, Abraham P.; Schumann, Daniel L.; Silva, Luiz Da

    2000-01-01

    A system for releasing a target material, such as an embolic coil from an SMP located at the end of a catheter utilizing an optical arrangement for releasing the material. The system includes a laser, laser driver, display panel, photodetector, fiber optics coupler, fiber optics and connectors, a catheter, and an SMP-based gripper, and includes a release sensing and feedback arrangement. The SMP-based gripper is heated via laser light through an optic fiber causing the gripper to release a target material (e.g., embolic coil for therapeutic treatment of aneurysms). Various embodiments are provided for coupling the laser light into the SMP, which includes specific positioning of the coils, removal of the fiber cladding adjacent the coil, a metal coating on the SMP, doping the SMP with a gradient absorbing dye, tapering the fiber optic end, coating the SMP with low refractive index material, and locating an insert between the fiber optic and the coil.

  13. Adverse perinatal outcomes in borderline amniotic fluid index.

    PubMed

    Jamal, Ashraf; Kazemi, Maryam; Marsoosi, Vajiheh; Eslamian, Laleh

    2016-11-01

    Normal amniotic fluid predicts normal placental function, fetal growth and fetal well-being. To determine adverse pregnancy outcomes in borderline amniotic fluid index (AFI). Pregnant women (37-40 wks) with diagnosis of borderline AFI between December 2012 and August 2014 were identified. Antepartum, intrapartum and neonatal data were collected and compared with those of pregnant women with normal AFI. An AFI less than 8 and more than 5 cm was defined for borderline AFI. Pregnancy outcomes included Cesarean section for non-reassuring fetal heart rate, meconium stained amniotic fluid, 5-min Apgar score <7, low birth weight, umbilical cord blood pH at term and NICU admission. Gestational age at delivery in pregnancies with borderline AFI was significantly lower than normal AFI. Cesarean section rate for non-reassuring fetal heart rate in women of borderline AFI was significantly higher and there was an increased incidence of birth weight less than 10 th percentile for gestation age in borderline AFI group. Incidence of low Apgar score and low umbilical artery pH in pregnancies with borderline AFI was significantly higher than women with normal AFI. There were no significant difference in the rate of NICU admission and meconium staining in both groups. There are significant differences for adverse pregnancy outcomes , such as Cesarean section due to non-reassuring fetal heart rate, birth weight less than 10 th percentile for gestation age, low 5 min Apgar score and low umbilical artery pH between pregnancies with borderline and normal AFI.

  14. Amniotic fluid index predicts the relief of variable decelerations after amnioinfusion bolus.

    PubMed

    Spong, C Y; McKindsey, F; Ross, M G

    1996-10-01

    Our purpose was to determine whether intrapartum amniotic fluid index before amnioinfusion can be used to predict response to therapeutic amnioinfusion. Intrapartum patients (n = 85) with repetitive variable decelerations in fetal heart rate that necessitated amnioinfusion (10 ml/min for 60 minutes) underwent determination of amniotic fluid index before and after bolus amnioinfusion. The fetal heart tracing was scored (scorer blinded to amniotic fluid index values) for number and characteristics of variable decelerations before and 1 hour after initiation of amnioinfusion. The amnioinfusion was considered successful if it resulted in a decrease of > or = 50% in total number of variable decelerations or a decrease of > or = 50% in the rate of atypical or severe variable decelerations after administration of the bolus. Spontaneous vaginal births before completion of administration of the bolus (n = 18) were excluded from analysis. The probability of success of amnioinfusion in relation to amniotic fluid index was analyzed with the chi(2) test for progressive sequence. The mean amniotic fluid index before amnioinfusion was 6.2 +/- 3.3 cm. An amniotic fluid index of < or = 5 cm was present in 40% of patients (27/67), and an amniotic fluid index of < or = 8 cm was present in 72% of patients (48/67). The probability of success of amnioinfusion decreased with increasing amniotic fluid index before amnioinfusion (76% [16/21] when initial amniotic fluid index was 0 to 4 cm, 63% [17/27] when initial amniotic fluid index was 4 to 8 cm, 44% [7/16] when initial amniotic fluid index was 8 to 12 cm, and 33% [1/3] when initial amniotic fluid index was > 12 cm, p = 0.03). The incidence of nuchal cords or true umbilical cord knots increased in relation to amniotic fluid index before amnioinfusion. Amniotic fluid index before amnioinfusion can be used to predict the success of amnioinfusion for relief of variable decelerations in fetal heart rate. Failure of amnioinfusion at a high amniotic fluid index before amnioinfusion may be explained by the increased prevalence of nuchal cords or true knots in the umbilical cord.

  15. Relationship between umbilical cord essential fatty acid content and the quality of general movements of healthy term infants at 3 months.

    PubMed

    Bouwstra, Hylco; Dijck-Brouwer, Da Janneke; Decsi, Tamás; Boehm, Günther; Boersma, E Rudy; Muskiet, Frits A J; Hadders-Algra, Mijna

    2006-05-01

    Prenatal essential fatty acid (EFA) status might be an important factor in the development of the central nervous system (CNS). The aim of the present study was to evaluate the relationship between the fatty acid compositions of the umbilical blood vessels at birth, used as a proxy of prenatal EFA status, and quality of general movements (GMs) at 3 mo. Umbilical artery and vein fatty acid compositions were investigated in a mixed group of breastfed infants and infants fed with formula with or without long-chain polyunsaturated fatty acid (LCPUFA) supplementation. At the age of 3 mo, video assessment of the quality of GMs was performed to evaluate neurologic condition. The quality of GMs was scored by assessing the degree of variation, complexity, and fluency. Outcomes were classified as normal-optimal, normal suboptimal, mildly abnormal, and definitely abnormal movements. Information on potential confounders, including the type of postnatal feeding, was collected prospectively. Associations between fatty acid status at birth and quality of GMs were investigated, and multinomial logistic regression analyses were carried out. None of the infants showed definitely abnormal movements. Infants with mildly abnormal GMs had a lower EFA index, lower arachidonic acid (AA) content, higher total n-9 fatty acid, and higher total monounsaturated fatty acid (MUFA) content in the umbilical artery compared with infants with normal GMs. Multivariate analyses confirmed these findings. We conclude that mildly abnormal GMs are associated with a less favorable EFA status in the umbilical artery.

  16. Predicting umbilical artery pH during labour: Development and validation of a nomogram using fetal heart rate patterns.

    PubMed

    Ramanah, Rajeev; Omar, Sikiyah; Guillien, Alicia; Pugin, Aurore; Martin, Alain; Riethmuller, Didier; Mottet, Nicolas

    2018-06-01

    Nomograms are statistical models that combine variables to obtain the most accurate and reliable prediction for a particular risk. Fetal heart rate (FHR) interpretation alone has been found to be poorly predictive for fetal acidosis while other clinical risk factors exist. The aim of this study was to create and validate a nomogram based on FHR patterns and relevant clinical parameters to provide a non-invasive individualized prediction of umbilical artery pH during labour. A retrospective observational study was conducted on 4071 patients in labour presenting singleton pregnancies at >34 gestational weeks and delivering vaginally. Clinical characteristics, FHR patterns and umbilical cord gas of 1913 patients were used to construct a nomogram predicting an umbilical artery (Ua) pH <7.18 (10th centile of the study population) after an univariate and multivariate stepwise logistic regression analysis. External validation was obtained from an independent cohort of 2158 patients. Area under the receiver operating characteristics (ROC) curve, sensitivity, specificity, positive and negative predictive values of the nomogram were determined. Upon multivariate analysis, parity (p < 0.01), induction of labour (p = 0.01), a prior uterine scar (p = 0.02), maternal fever (p = 0.02) and the type of FHR (p < 0.01) were significantly associated with an Ua pH <7.18 (p < 0.05). Apgar score at 1, 5 and 10 min were significantly lower in the group with an Ua pH <7.18 (p < 0.01). The nomogram constructed had a Concordance Index of 0.75 (area under the curve) with a sensitivity of 57%, a specificity of 91%, a negative predictive value of 5% and a positive predictive value of 99%. Calibration found no difference between the predicted probabilities and the observed rate of Ua pH <7.18 (p = 0.63). The validation set had a Concordance Index of 0.72 and calibration with a p < 0.77. We successfully developed and validated a nomogram to predict Ua pH by combining easily available clinical variables and FHR. Discrimination and calibration of the model were statistically good. This mathematical tool can help clinicians in the management of labour by predicting umbilical artery pH based on FHR tracings. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. Sildenafil citrate and uteroplacental perfusion in fetal growth restriction

    PubMed Central

    Dastjerdi, Marzieh Vahid; Hosseini, Sayedehafagh; Bayani, Leila

    2012-01-01

    Background: To determine whether the phosphodiesterase type 5 inhibitor, Sildenafil citrate, affects uteroplacental perfusion. Materials and Methods: Based on a randomized double-blinded and placebo-controlled trial, forty one pregnant women with documented intrauterine growth retardation at 24-37 weeks of gestation were evaluated for the effect of a single dose of Sildenafil citrate on uteroplacental circulation as determined by Doppler ultrasound study of the umbilical and middle cerebral arteries. Statistical analysis included χ2-test to compare proportions, and independent-samples t-test and paired student's t-test to compare continuous variables. Results: Sildenafil group fetuses demonstrated a significant decrease in systolic/diastolic ratios (0.60 [SD 0.40] [95% Cl 0.37-0.84], P=0.000), and pulsatility index (0.12 [SD 0.15] [95% Cl 0.02-0.22], P=0.019) for the umbilical artery and a significant increase in middle cerebral artery pulsatility index (MCA PI) (0.51 [SD 0.60] [95% Cl 0.16-0.85], P=0.008). Conclusion: Doppler velocimetry index values reflect decreased placental bed vascular resistance after Sildenafil. Sildenafil citrate can improve fetoplacental perfusion in pregnancies complicated by intrauterine growth restriction. It could be a potential therapeutic strategy to improve uteroplacental blood flow in pregnancies with fetal growth restriction (FGR). PMID:23798922

  18. Fetal vascular adaptation before and after treatment of severe maternal anemia in pregnancy.

    PubMed

    Ali, Eram; Kumar, Manisha; Naqvi, Sayyed E H; Trivedi, Shubha S; Singh, Anuradha

    2016-06-01

    To use color Doppler ultrasonography indices to study the effects on fetal circulation of treating severe maternal anemia. A prospective cohort study enrolled patients who were at 30-34weeks of pregnancy and had hemoglobin levels below 70g/L between November 1, 2011 and March 31, 2013 at a hospital in New Delhi, India. A control group consisting of patients with the same duration of pregnancy and with hemoglobin levels above 110g/L was included. Umbilical artery and middle cerebral artery velocimetry were performed using color Doppler ultrasonography at admission and after 4weeks and 6weeks of treatment. The maternal anemia cohort demonstrated a significantly lower middle cerebral artery resistance index and middle cerebral/umbilical artery resistance ratio (P<0.001) at admission. Following 4weeks of treatment for maternal anemia, significant increases in these parameters were observed (P<0.001). Fetuses of individuals with severe maternal anemia demonstrated altered cerebral and umbilical artery flows. Normal flows were restored following treatment of maternal anemia. Copyright © 2016 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.

  19. Evaluation of the use of umbilical artery Doppler flow studies and outcome of pregnancies at a secondary hospital.

    PubMed

    Hugo, Elizabeth J C; Odendaal, Hein J; Grove, Debbie

    2007-03-01

    To investigate the use of a personal computer (PC)-based, continuous-wave Doppler machine by a trained midwife at a secondary hospital to assess umbilical artery flow velocity waveforms (FVW) in referred women. Pregnant women referred for suspected poor fetal growth were evaluated from June 2002 through December 2004. The Umbiflow apparatus, consisting of a Pentium 3 PC with an ultrasound transducer plugged into the USB port and software, was used to analyze the FVW of the umbilical artery. Pregnancies in which the resistance index (RI) was <75(th) percentile (P75) were not further evaluated for fetal well-being unless the clinical condition of the mother changed. Pregnancies with an RI >or=P75 were followed up according to a specific protocol. Primary end points were intrauterine death and intrauterine growth restriction. A total of 572 singleton pregnancies were followed up. Significantly more infants were small-for-gestational-age when the RI was >P95 (55.6%) than those between P75 and P95 (41.2%) or P95, respectively. A normal Doppler FVW of the umbilical artery is less likely to be followed by perinatal death.

  20. Space-coiling metamaterials with double negativity and conical dispersion

    PubMed Central

    Liang, Zixian; Feng, Tianhua; Lok, Shukin; Liu, Fu; Ng, Kung Bo; Chan, Chi Hou; Wang, Jinjin; Han, Seunghoon; Lee, Sangyoon; Li, Jensen

    2013-01-01

    Metamaterials are effectively homogeneous materials that display extraordinary dispersion. Negative index metamaterials, zero index metamaterials and extremely anisotropic metamaterials are just a few examples. Instead of using locally resonating elements that may cause undesirable absorption, there are huge efforts to seek alternative routes to obtain these unusual properties. Here, we demonstrate an alternative approach for constructing metamaterials with extreme dispersion by simply coiling up space with curled channels. Such a geometric approach also has an advantage that the ratio between the wavelength and the lattice constant in achieving a negative or zero index can be changed in principle. It allows us to construct for the first time an acoustic metamaterial with conical dispersion, leading to a clear demonstration of negative refraction from an acoustic metamaterial with airborne sound. We also design and realize a double-negative metamaterial for microwaves under the same principle. PMID:23563489

  1. Doppler Audio Signal Analysis as an Additional Tool in Evaluation of Umbilical Artery Circulation.

    PubMed

    Thuring, Ann; Källén, Karin; Brännström, K Jonas; Jansson, Tomas; Maršál, Karel

    2017-10-01

    Purpose  To investigate the predictive capacity of a new method for sound spectrum analysis of Doppler signals recorded from the umbilical artery in high-risk pregnancies. Material and Methods  The retrospective study comprised 127 pregnant women with various pregnancy complications between 23 and 39 gestational weeks. Umbilical artery blood flow velocity waveforms were recorded with Doppler ultrasound and characterized by pulsatility index (PI) and blood flow class (BFC). Doppler audio signals were stored on a digital video recorder and the sound frequency at the energy level 15 dB below its peak (MAX peak-15 dB ) was estimated off-line. The prediction of probability for composite adverse pregnancy outcome (operative delivery for fetal distress, admission to neonatal intensive care unit, perinatal death) was evaluated using the area under the curve (AUC) of the receiver operating characteristics (ROC) curve. Results  With increasing umbilical artery BFC, the MAX peak-15 dB frequencies decreased (p < 0.0001) and the PI increased (p < 0.0001). The ROC AUCs for adverse outcome for MAX peak-15 dB and for PI were 0.842 and 0.836 (p = 0.88), respectively. For the combination of MAX peak-15 dB and PI, the corresponding AUC was 0.894, significantly higher than that of PI (p < 0.03) and of MAX peak-15 dB (p < 0.05). Conclusion  Umbilical artery Doppler sound spectrum analysis might be a useful supplement to PI in the clinical evaluation of fetoplacental circulation. © Georg Thieme Verlag KG Stuttgart · New York.

  2. Effect of γ-Al2O3/water nanofluid on the thermal performance of shell and coil heat exchanger with different coil torsions

    NASA Astrophysics Data System (ADS)

    Elshazly, K. M.; Sakr, R. Y.; Ali, R. K.; Salem, M. R.

    2017-06-01

    This work investigated experimentally the thermal performance of shell and coil heat exchanger with different coil torsions (λ) for γ-Al2O3/water nanofluid flow. Five helically coiled tube (HCT) with 0.0442 ≤ λ ≤ 0.1348 were tested within turbulent flow regime. The average size of γ-Al2O3 particles is 40 nm and volume concentration (φ) is varied from 0 to 2%. Results showed that reducing coil torsion enhances the heat transfer rate and increases HCT-friction factor (fc). Also, it is noticed that HCT average Nusselt number (Nut) and fc of nanofluids increase with increasing γ-Al2O3 volume concentration. The thermal performance index, TPI = (ht,nf/ht,bf)/(ΔPc,nf/ΔPc,bf). increases with increasing nanoparticles concentration, coil torsion, HCT-side inlet temperature and nanofluid flow rate. Over the studied range of HCT-Reynolds number, the average value of TPI is of 1.34 and 2.24 at φ = 0.5% and φ = 2%, respectively. The average value of TPI is of 1.64 at λ = 0.0442 while its average value at λ = 0.1348 is of 2.01. One of the main contributions is to provide heat equipments designers with Nut and fc correlations for practical configurations shell and coil heat exchangers with a wide range of nanofluid concentration.

  3. Construction and Test Results of Coil 2 of a Three-Coil 800-MHz REBCO Insert for the 1.3-GHz High-Resolution NMR Magnet.

    PubMed

    Bascuñán, Juan; Michael, Philip; Hahn, Seungyong; Lecrevisse, Thibault; Iwasa, Yukikazu

    2017-06-01

    This paper focuses on the construction and test results of Coil 2 that is part of a trio of nested coils composing the REBCO 800 MHz insert. Upon its completion, the REBCO 800 MHz insert will be placed in the bore of a 500 MHz low temperature superconducting (LTS) NMR magnet (L500) to form the MIT 1.3 GHz high-resolution NMR magnet. Coil 2 is a stack of 32 double pancake (DP) coils wound with 6-mm wide REBCO tape using the no-insulation (NI) technique. Each pancake is wound on a stainless steel inner supporting ring to prevent the collapsing of its crossover due to the external pressure exerted by the winding pack. Coil 2 will be constructed in the following sequence: 1) after winding each DP will be individually tested in a bath of liquid nitrogen at atmospheric pressure to determine its current carrying capabilities; 2) DPs will be then assembled as a stack with interconnecting joints, and 3) as in Coil 1, each pancake will be overbanded with a stainless steel tape, this time to a thickness of 5 mm, thickness determined by a stress analysis previously performed. Finally the fully assembled Coil 2 will be tested in liquid nitrogen at 77 K and then in liquid helium at 4.2 K. We present here details of the stress analysis leading to the sizing of the DP inner supporting stainless steel ring and of the overbanding thickness required. Test results include coil index, critical current, charging time constant.

  4. An exploration of advanced X-divertor scenarios on ITER

    NASA Astrophysics Data System (ADS)

    Covele, B.; Valanju, P.; Kotschenreuther, M.; Mahajan, S.

    2014-07-01

    It is found that the X-divertor (XD) configuration (Kotschenreuther et al 2004 Proc. 20th Int. Conf. on Fusion Energy (Vilamoura, Portugal, 2004) (Vienna: IAEA) CD-ROM file [IC/P6-43] www-naweb.iaea.org/napc/physics/fec/fec2004/datasets/index.html, Kotschenreuther et al 2006 Proc. 21st Int. Conf. on Fusion Energy 2006 (Chengdu, China, 2006) (Vienna: IAEA), CD-ROM file [IC/P7-12] www-naweb.iaea.org/napc/physics/FEC/FEC2006/html/index.htm, Kotschenreuther et al 2007 Phys. Plasmas 14 072502) can be made with the conventional poloidal field (PF) coil set on ITER (Tomabechi et al and Team 1991 Nucl. Fusion 31 1135), where all PF coils are outside the TF coils. Starting from the standard divertor, a sequence of desirable XD configurations are possible where the PF currents are below the present maximum design limits on ITER, and where the baseline divertor cassette is used. This opens the possibility that the XD could be tested and used to assist in high-power operation on ITER, but some further issues need examination. Note that the increased major radius of the super-X-divertor (Kotschenreuther et al 2007 Bull. Am. Phys. Soc. 53 11, Valanju et al 2009 Phys. Plasmas 16 5, Kotschenreuther et al 2010 Nucl. Fusion 50 035003, Valanju et al 2010 Fusion Eng. Des. 85 46) is not a feature of the XD geometry. In addition, we present an XD configuration for K-DEMO (Kim et al 2013 Fusion Eng. Des. 88 123) to demonstrate that it is also possible to attain the XD configuration in advanced tokamak reactors with all PF coils outside the TF coils. The results given here for the XD are far more encouraging than recent calculations by Lackner and Zohm (2012 Fusion Sci. Technol. 63 43) for the Snowflake (Ryutov 2007 Phys. Plasmas 14 064502, Ryutov et al 2008 Phys. Plasmas 15 092501), where the required high PF currents represent a major technological challenge. The magnetic field structure in the outboard divertor SOL (Kotschenreuther 2013 Phys. Plasmas 20 102507) in the recently created XD configurations reproduces what was presented in the earlier XD papers (Kotschenreuther et al 2004 Proc. 20th Int. Conf. on Fusion Energy (Vilamoura, Portugal, 2004) (Vienna: IAEA) CD-ROM file [IC/P6-43] www-naweb.iaea.org/napc/physics/fec/fec2004/datasets/index.html, Kotschenreuther et al 2006 Proc. 21st Int. Conf. on Fusion Energy 2006 (Chengdu, China, 2006) (Vienna: IAEA) CD-ROM file [IC/P7-12] www-naweb.iaea.org/napc/physics/FEC/FEC2006/html/index.htm, Kotschenreuther et al 2007 Phys. Plasmas 14 072502). Consequently, the same advantages accrue, but no close-in PF coils are employed.

  5. Umbilical hernia repair with mesh: identifying effectors of ideal outcomes.

    PubMed

    Colavita, Paul D; Belyansky, Igor; Walters, Amanda L; Zemlyak, Alla Y; Lincourt, Amy E; Heniford, B Todd; Augenstein, Vedra A

    2014-09-01

    Quality of life has become an important focus for improvement in hernia repair. The International Hernia Mesh Registry was queried. The Carolinas Comfort Scale quantitated quality of life at 1-month, 6-month, and annual follow-up. Scores of 0 (completely asymptomatic) in all categories without recurrence defined an ideal outcome. The analysis consisted of 363 umbilical hernia repairs; 18.7% were laparoscopic. Demographics included age of 51.5 ± 13.8 years, 24.5% were female, and the average body mass index was 30.63 ± 5.9 kg/m(2). Mean defect size was 4.3 ± 3.1 cm(2). Mean follow-up was 18.2 months. Absent/minimal preoperative symptoms were predictive of ideal outcome at all time points and increasing age was predictive at 6 months and 1 year. At 6 months, the use of fixation sutures alone versus tacks (odds ratio 14.1) predicted ideal outcome. Ideal outcomes are dependent on both patient-specific and operative factors. The durable, ideal outcome in umbilical hernia repair is most likely in an older, asymptomatic patient who undergoes mesh fixation with permanent suture. Copyright © 2014 Elsevier Inc. All rights reserved.

  6. Associations between intrapartum death and piglet, placental, and umbilical characteristics.

    PubMed

    Rootwelt, V; Reksen, O; Farstad, W; Framstad, T

    2012-12-01

    Intrapartum death in multiparous gestations in sows (Sus scrofa) is often caused by hypoxia. There is little information in the literature on the assessment of the placenta in relation to intrapartum death in piglets. The aim of this study was to evaluate the impact of the placental area and weight upon piglet birth characteristics and intrapartum death. Litters from 26 Landrace-Yorkshire sows were monitored during farrowing and the status of each piglet was recorded, including blood parameters of piglets and their umbilical veins. Of 413 piglets born, 6.5% were stillborn. Blood concentrations of glucose, lactate, and CO(2) partial pressure were increased in the stillborn piglets (P < 0.05) and corresponding umbilical veins (P < 0.01) vs. live-born piglets, whereas pH and base excess were decreased (P < 0.001). Time from onset of parturition until birth was increased for piglets born dead vs. live (P < 0.001). Mean birth weight for piglets born dead was not different from live-born piglets (P = 0.631), whereas mean body mass index was reduced (P < 0.001). Mean placental area and placental weight belonging to stillborn piglets were not different from live-born piglets (P = 0.662 and P = 0.253, respectively). Blood concentrations of lactate, hemoglobin, and hematocrit recorded in all piglets pooled were associated with placental area (P < 0.05), but not with placental weight (P > 0.2). Piglet BW was positively correlated with placental area and placental weight (P < 0.001). The risk of being born dead increased with increasing birth order group, and broken umbilical cords explained 71% of the stillbirths (P = 0.001). We conclude that placental area and placental weight are both positively associated with piglet birth weight, but not with the probability of being born dead. Placental area was a better predictor of piglet vitality than placental weight. Because umbilical cord rupture and prolonged birth time were associated with being born dead, umbilical cord rupture and placental detachment seem to be probable causes of intrapartum death.

  7. Hemodynamic adaptation to suboptimal fetal growth in patients with single ventricle physiology.

    PubMed

    Alsaied, Tarek; Tseng, Stephanie; King, Eileen; Hahn, Eunice; Divanovic, Allison; Habli, Mounira; Cnota, James

    2018-06-10

    In fetuses with structurally normal heart and suboptimal fetal growth (SFG), umbilical artery vascular resistance increases as measured by umbilical artery pulsatility index (UA-PI). The objective of this study is to compare hemodynamic responses to SFG in fetuses with single ventricle (SV) and controls with structurally normal heart. Fetal echocardiograms around 30 weeks of gestation were reviewed. UA-PI and middle cerebral artery pulsatility index (MCA-PI) were calculated. SFG was defined as a birth weight below 25th percentile for gestational age. Studies from 92 fetuses were reviewed-SV (n = 50) and controls (n = 42). The prevalence of SFG was higher in SV compared to controls (46% vs 21%, P = .02). In patients with normal heart and SFG, UAPI was significantly higher than normal controls (P = .003) suggesting increased placental vascular resistance. In SV with SFG there was no difference in UAPI compared to SV without SFG. There was no difference in MCA-PI between the groups. The hemodynamic response to SFG in SV varies from fetuses with structurally normal heart. The mechanism of SFG and the placental pathology may be distinct in SV. © 2018 Wiley Periodicals, Inc.

  8. Neonatal, placental, and umbilical cord blood parameters in pregnant women residing in areas with intensive pesticide application.

    PubMed

    Quintana, María Martha; Vera, Berta; Magnarelli, Gladis; Guiñazú, Natalia; Rovedatti, María Gabriela

    2017-09-01

    In rural populations, the proximity to areas with intensive pesticide application represents a risk factor of xenobiotic exposure. Here, we investigated whether newborns born to mothers residing in an area with intensive pesticide application show alterations in placental and neonatal morphometric standards, umbilical cord blood (UCB) biochemical parameters, and/or biomarkers related to oxidative stress and oxidative damage. Samples were collected from 151 healthy pregnant women residing in a rural area (rural group; RG) during the pesticide spraying (SS) and nonspraying (NSS) seasons, as well as from women from an urban population (control group; CG), and grouped according to the delivery type (vaginal or cesarean). In the vaginal delivery group, the placental weight and placental index were higher in the RG groups than in the CG (p = 0.01), whereas in the cesarean delivery group, newborn weight was lower in the RG-SS group than in the CG. In the RG-SS group, UCB erythrocyte osmotic fragility and the DNA damage index (DI) were higher, and superoxide dismutase (SOD) activity was lower than in the RG-NSS group. Acetylcholinesterase and SOD activities were found to be inversely correlated with the DI.

  9. Maternal systemic or cord blood inflammation is associated with birth anthropometry in a Tanzanian prospective cohort.

    PubMed

    Wilkinson, A L; Pedersen, S H; Urassa, M; Michael, D; Andreasen, A; Todd, J; Kinung'hi, S M; Changalucha, J; McDermid, J M

    2017-01-01

    HIV infection is associated with chronic systemic inflammation, with or without antiretroviral therapy. Consequences for foetal growth are not understood, particularly in settings where multiple maternal infections and malnutrition are common. The study was designed to examine maternal systemic circulating and umbilical cord blood cytokine concentrations in relation to birth anthropometry in a Tanzanian prospective cohort. A 9-plex panel of maternal plasma cytokines in HIV-positive (n = 44) and HIV-negative (n = 70) mothers and the same cytokines in umbilical cord blood collected at delivery was assayed. Linear regression modelled associations between maternal or cord blood cytokines and birth anthropometry. Health indicators (haemoglobin, mid-upper-arm circumference, body mass index) in HIV-positive mothers without considerable immunosuppression did not differ from HIV-negative women. Despite this, HIV-exposed infants had lower birthweight and length. Subgroup analyses indicated that HIV management using HAART was associated with lower plasma TNF-α, as were longer durations of any antiretroviral therapy (≥2 months). Greater maternal plasma TNF-α was associated with earlier delivery (-1.7 weeks, P = 0.039) and lower birthweights (-287 g; P = 0.020), while greater umbilical cord TNF-α (-1.43 cm; P = 0.036) and IL-12p70 (-2.4 cm; P = 0.008) were associated with shorter birth length. Birthweight was inversely associated with cord IL-12p70 (-723 g; P = 0.001) and IFN-γ (-482 g, P = 0.007). Maternal cytokines during pregnancy did not correlate with umbilical cord cytokines at delivery. Systemic inflammation identified in maternal plasma or umbilical cord blood was associated with poorer birth anthropometrics in HIV-exposed and HIV-unexposed infants. Controlling maternal and/or foetal systemic inflammation may improve birth anthropometry. © 2016 The Authors. Tropical Medicine & International Health Published by John Wiley & Sons Ltd.

  10. Umbilical endometriosis associated with large umbilical hernia. Case report.

    PubMed

    Stojanovic, M; Radojkovic, M; Jeremic, L; Zlatic, A; Stanojevic, G; Janjic, D; Mihajlovic, S; Dimov, I; Kostov, M; Zdravkovic, M; Stojanovic, M

    2014-01-01

    Umbilical endometriosis is a rare condition, usually following laparoscopic and surgical procedures involving the umbilicus.Spontaneous umbilical endometriosis occurring without any previous abdominal or uterine surgery is extremely rare. The maximal depth of penetration of the umbilical endometriosis described is up to fascial level. There have been only two cases of endometriosis reported arising within umbilical hernia. The authors report a case of a patient with spontaneous umbilical endometriosis associated with a large umbilical hernia, treated by surgical excision and mesh repair of the abdominal wall. To the best of our knowledge, this is the first described case of the association of umbilical endometriosis with a large umbilical hernia that requires prosthetic mesh repair of the abdominal wall defect. Celsius.

  11. The intra-umbilical approach in umbilical hernia.

    PubMed

    Arslan, Sukru; Korkut, Ercan

    2014-02-01

    To investigate the "intra-umbilical incision", a smaller incision compared to classic incisions, in cases of umbilical hernia, and which we believe will contribute to patient satisfaction in aesthetic terms, and also the practicability of such operations. The umbilical margins of eight patients with an umbilical hernia were marked between the levels of 6 and 12 o'clock, and a median intra-umbilical skin incision was performed between these two points. In some cases, where exploration could not be performed sufficiently, the incision was extended horizontally from 6 or 12 o'clock. Hernia repair and mesh placement was then performed using an intra-umbilical approach. Patients were investigated according to the defect size and requirement for intra-umbilical incision extension. No requirement for intra-umbilical incision was encountered in six patients with a facial defect diameter smaller than 4 cm, while the incision had to be extended in two patients with defects greater than 4 cm. The intra-umbilical approach in umbilical hernia surgery is aesthetically superior to classical approaches and is a practicable technique.

  12. Intravenous human umbilical cord blood improves electrophysiological and metabolic properties in ISO induced myocardial necrosis in rats.

    PubMed

    Mohan, Mahalaxmi; Rokade, Rahul; Kasturet, Sanjay

    2013-03-01

    Rats treated with isoproterenol (ISO, 85 mg/kg, sc, twice at an interval of 24 h) showed a significant increase in heart rate, mean arterial blood pressure, pressure rate index, ST elevation on ECG, and a significant increase in the levels of cardiac marker enzymes- lactate dehydrogenase, and creatine kinase in serum and a significant reduction in superoxide dismutase, and catalase and increase in thiobarbituric acid reactive substance activity in heart tissue. Treatment with Human umbilical cord blood (hUCBC; 500 and 1000 microL, iv, via the tail vein; 2 h after the second dose of ISO) significantly restored back to normal levels and showed a lesser degree of cellular infiltration and infarct size in histopathological and planimetry studies respectively. Thus, hUCBC ameliorates cardiotoxic effects of isoproterenol and may be of value in the treatment of myocardial infarction.

  13. MANAGEMENT OF OMPHALOPHLEBITIS AND UMBILICAL HERNIA IN THREE NEONATAL GIRAFFE (GIRAFFA CAMELOPARDALIS).

    PubMed

    Selig, Michael; Lewandowski, Albert; Burton, Michael S; Ball, Ray L

    2015-12-01

    Umbilical disorders, including omphalophlebitis, omphaloarteritis, external umbilical abscesses, urachal abscesses, patent urachus, and umbilical hernias, represent a significant challenge to the health and well-being of a neonate. The three neonatal giraffe (Giraffa camelopardalis) in this report were evaluated for umbilical swellings. Two developed omphalophlebitis, and one had an uncomplicated umbilical hernia. Omphalophlebitis is an inflammation and/or infection of the umbilical vein. Giraffe calves with a failure of passive transfer may be predisposed and should be thoroughly evaluated for the condition. Umbilical hernias result from a failure of the umbilical ring to close after parturition or from malformation of the umbilical ring during embryogenesis. These problems were surgically corrected for all three individuals, although one died due to postsurgical complications. The risks involved include anesthetic complications, surgical dehiscence, and maternal rejection. Early detection and surgical intervention are recommended for the correction of omphalophlebitis and umbilical hernias in neonatal giraffe.

  14. [Measurement of umbilical activin A level in preterm infants].

    PubMed

    Zhong, Ying; Li, Juan; Wei, Ke-Lun

    2011-10-01

    To evaluate the clinical significance of umbilical activin A in preterm infants. Forty-one preterm infants (gestation 28 to 36 weeks) were enrolled. Fetal membranes, umbilical cords and blood samples from umbilical vein were obtained. Umbilical activin A level was measured using ELISA. The histological examinations of fetal membranes and umbilical cords were performed. The umbilical level of activin A averaged 2069 pg/mL in the 41 preterm infants. The umbilical activin A level in the 5 infants with intrauterine infection was higher than in those without intrauterine infection (2510 pg/mL vs 1975 pg/mL; P<0.01). Umbilical activin A level at cutoff of 2490 pg/mL showed a sensitivity of 80.0% and a specificity of 90.6% as a marker of intrauterine infection. There were no significant differences in the umbilical activin A level between the infants with and without respiratory distress syndrome. Umbilical activin A level was positively correlated with the duration of postnatal oxygen therapy (r=0.326, P<0.05). Umbilical activin A may serve a marker of intrauterine infection in preterm infants. The umbilical activin A level is correlated with the duration of postnatal oxygen therapy.

  15. Sonographic diagnosis and clinical significance of umbilical arterial atresia.

    PubMed

    Ren, Jinhe

    2017-05-01

    To evaluate the feasibility of antenatal sonographic diagnosis of umbilical arterial atresia and its clinical significance. Data of 5 cases with umbilical arterial atresia diagnosed in our hospital were studied retrospectively. The antenatal ultrasonogram of umbilical arterial atresia was obtain, and the pathological examination of umbilical cords and the prognosis of neonates were analyzed. Among 5 cases with umbilical arterial atresia in this group, 1 case with double umbilical arterial atresia was found with dead fetus in uterus, and the rest 4 cases with single umbilical arterial atresia were found with survival fetuses. In the latter 4 cases with live fetus, once umbilical arterial atresia was diagnosed, cesarean section was performed to terminate pregnancy, and the 4 fetus were all healthy. The chromosome karyotypes and S/D value of umbilical arteries were showed normal in all 5 cases. Accurate antenatal diagnosis can be made according to the specific ultrasonogram of umbilical arterial atresia. Instant intervention should be performed upon observing umbilical arterial atresia with live fetus, so as to avoid dead fetus as much as possible.

  16. The Intra-Umbilical Approach in Umbilical Hernia

    PubMed Central

    Arslan, Sukru; Korkut, Ercan

    2014-01-01

    Objective: To investigate the “intra-umbilical incision”, a smaller incision compared to classic incisions, in cases of umbilical hernia, and which we believe will contribute to patient satisfaction in aesthetic terms, and also the practicability of such operations. Materials and Methods: The umbilical margins of eight patients with an umbilical hernia were marked between the levels of 6 and 12 o’clock, and a median intra-umbilical skin incision was performed between these two points. In some cases, where exploration could not be performed sufficiently, the incision was extended horizontally from 6 or 12 o’clock. Hernia repair and mesh placement was then performed using an intra-umbilical approach. Results: Patients were investigated according to the defect size and requirement for intra-umbilical incision extension. No requirement for intra-umbilical incision was encountered in six patients with a facial defect diameter smaller than 4 cm, while the incision had to be extended in two patients with defects greater than 4 cm. Conclusion: The intra-umbilical approach in umbilical hernia surgery is aesthetically superior to classical approaches and is a practicable technique. PMID:25610291

  17. Robust SMES controller design for stabilization of inter-area oscillation considering coil size and system uncertainties

    NASA Astrophysics Data System (ADS)

    Ngamroo, Issarachai

    2010-12-01

    It is well known that the superconducting magnetic energy storage (SMES) is able to quickly exchange active and reactive power with the power system. The SMES is expected to be the smart storage device for power system stabilization. Although the stabilizing effect of SMES is significant, the SMES is quite costly. Particularly, the superconducting magnetic coil size which is the essence of the SMES, must be carefully selected. On the other hand, various generation and load changes, unpredictable network structure, etc., cause system uncertainties. The power controller of SMES which is designed without considering such uncertainties, may not tolerate and loses stabilizing effect. To overcome these problems, this paper proposes the new design of robust SMES controller taking coil size and system uncertainties into account. The structure of the active and reactive power controllers is the 1st-order lead-lag compensator. No need for the exact mathematical representation, system uncertainties are modeled by the inverse input multiplicative perturbation. Without the difficulty of the trade-off of damping performance and robustness, the optimization problem of control parameters is formulated. The particle swarm optimization is used for solving the optimal parameters at each coil size automatically. Based on the normalized integral square error index and the consideration of coil current constraint, the robust SMES with the smallest coil size which still provides the satisfactory stabilizing effect, can be achieved. Simulation studies in the two-area four-machine interconnected power system show the superior robustness of the proposed robust SMES with the smallest coil size under various operating conditions over the non-robust SMES with large coil size.

  18. Parasympathetic tone variations according to umbilical cord pH at birth: a computerized fetal heart rate variability analysis.

    PubMed

    Butruille, Laura; De Jonckheere, Julien; Flocteil, Mathilde; Garabedian, Charles; Houfflin-Debarge, Véronique; Storme, Laurent; Deruelle, Philippe; Logier, Régis

    2017-12-01

    Non-reassuring fetal heart rate tracings reflect an imbalance between the parasympathetic and sympathetic nervous systems. In this situation, fetal asphyxia can be suspected and may be confirmed by metabolic measurements at birth like low pH or high base deficit values. The objective of this study was to determine whether fetal asphyxia during labor is related to parasympathetic nervous system activity. This is a retrospective study of a database collected in 5 centers. Two hundred and ninety-nine fetal heart rate tracings collected during labor were analyzed. Autonomic nervous system, especially the parasympathetic nervous system, was analyzed using an original index: the FSI (Fetal Stress Index). The FSI is a parasympathetic activity evaluation based on fetal heart rate variability analysis. Infants were grouped based on normal or low pH value at birth. FSI was measured during the last 30 min of labor before birth and compared between groups. The minimum value of the FSI during the last 30 min before delivery was significantly lower in the group with the lower umbilical cord arterial pH value. In this pilot study during labor, FSI was lower in the group of infants with low arterial pH at birth.

  19. In vivo T-cell activation by a monoclonal αCD3ε antibody induces preterm labor and birth

    PubMed Central

    Gomez-Lopez, Nardhy; Romero, Roberto; Arenas-Hernandez, Marcia; Ahn, Hyunyoung; Panaitescu, Bogdan; Vadillo-Ortega, Felipe; Sanchez-Torres, Carmen; Salisbury, Katherine S; Hassan, Sonia S.

    2016-01-01

    PROBLEM Activated/effector T cells seem to play a role in the pathological inflammation associated with preterm labor. The aim of this study was to determine whether in vivo T-cell activation by a monoclonal αCD3ε antibody induces preterm labor and birth. METHOD OF STUDY Pregnant B6 mice were intraperitoneally injected with a monoclonal αCD3ε antibody or its isotype control. The gestational age and the rates of preterm birth and pup mortality at birth, as well as the fetal heart rate and umbilical artery pulsatility index, were determined. RESULTS Injection of a monoclonal αCD3ε antibody led to preterm labor/birth [αCD3ε 83 ± 16.97% (10/12) vs. isotype 0% (0/8)], and increased the rate of pup mortality at birth [αCD3ε 87.30 ± 8.95% (77/85) vs. isotype 4.91 ± 4.34% (3/59)]. In addition, injection of a monoclonal αCD3ε antibody decreased the fetal heart rate and increased the umbilical artery pulsatility index when compared to isotype controls. CONCLUSION In vivo T-cell activation by a monoclonal αCD3ε antibody in late gestation induces preterm labor and birth. PMID:27658719

  20. Correlation Between Maternal and Fetal Insulin Resistance in Pregnant Women with Gestational Diabetes Mellitus.

    PubMed

    Wang, Xuqin; Yang, Ting; Miao, Jingkun; Liu, Huan; Wu, Kaifeng; Guo, Jing; Chen, Jie; Li, Tingyu

    2018-06-01

    Offspring of mothers with gestational diabetes mellitus (GDM) are far more likely to develop type 2 diabetes. The aim of this study was to investigate the effect of the insulin metabolism of pregnant women with GDM in late pregnancy on the insulin metabolism of the fetuses and their correlation. This study enrolled 55 pregnant women with GDM and 87 control subjects. Fasting venous blood samples and umbilical venous blood samples (reflecting fetal metabolism) were collected from the study subjects. All blood samples were used to evaluate the blood glucose and insulin concentrations. The blood glucose and insulin concentrations were measured using an automatic biochemical analyser and radioimmunoassay, respectively. The homeostasis model assessment (HOMA) was performed to assess the insulin resistance of mother and fetus. 1. The fasting blood glucose, fasting insulin, and HOMA-IR of pregnant women in the late pregnancy GDM group were all significantly higher than those in the control group (fasting blood glucose: 4.70 ± 0.11 vs. 4.11 ± 0.05 mmol/L, p < 0.001; fasting insulin: 44.1 ± 6.76 vs. 25.1 ± 3.58 µU/mL, p = 0.013; HOMA-IR: 8.92 ± 1.25 vs. 5.39 ± 0.83, p = 0.012); 2. The results of logistic regression analyses showed that maternal age, pre-pregnancy body mass index (BMI), and family history of diabetes were high-risk factors for the development of GDM in pregnant women. 3. The insulin level and HOMA-IR in the umbilical venous blood of the late pregnancy GDM group were both significantly higher than those in the control group (insulin: 10.1 ± 1.41 vs. 6.38 ± 0.49 µU/mL, p = 0.035; HOMA-IR: 1.60 ± 0.22 vs. 1.07 ± 0.08, p = 0.006). 4. The umbilical venous blood HOMA-IR in the GDM group positively correlated with the maternal HOMA-IR and fasting insulin level. The neonatal ponderal index (PI) in the GDM group positively correlated with the umbilical venous blood HOMA-IR and insulin level. The HOMA-IR was significantly higher in the late pregnancy GDM women and their fetuses than in the control group. In addition, fetal HOMA-IR positively correlated to maternal HOMA-IR in late pregnancy GDM women.

  1. Cardiac index in term pregnant women in the sitting, lateral, and supine positions: an observational, crossover study.

    PubMed

    Armstrong, Sarah; Fernando, Roshan; Columb, Malachy; Jones, Tanya

    2011-08-01

    Aortocaval compression may affect maternal hemodynamic indices and fetal well-being in various maternal positions. There has been much debate regarding the optimal position for performing neuraxial blockade for labor analgesia and cesarean delivery. We hypothesized that in pregnant women at term, cardiac index (CI) may be improved in the lateral positions as compared with the flexed sitting position. Our primary outcome was to measure CI as assessed by suprasternal Doppler. A prospective, observational, crossover study was conducted in 25 ASA physical status I/II women with uncomplicated pregnancies presenting for elective cesarean delivery at term. Hemodynamic indices were measured in 4 positions in random order: supine with a 15-degree left tilt, sitting with neck and hips flexed, and flexed left lateral and flexed right lateral positions. Maternal CIs were measured using a noninvasive suprasternal Doppler device and upper arm noninvasive arterial blood pressure. Umbilical Dopplers were performed simultaneously to measure the fetal heart rate and umbilical artery pulsatility and resistivity indices. CI differed by position (P = 0.01); it was higher in the right lateral position compared with the sitting and supine positions (by 8.8% and 8.1%, respectively) and in the left lateral compared with sitting position (by 7.8%) (P < 0.05). Maternal stroke volume index, heart rate, and systolic blood pressure were higher in the lateral positions compared with the sitting and supine-tilt positions. We found no significant differences in fetal heart rate, pulsatility index, or resistivity index among positions. Positioning for neuraxial anesthesia may influence maternal hemodynamic variables. We found no difference in healthy fetal blood flow indices among positions, suggesting that these changes are not clinically significant. This study provides new physiological information on the changes that occur in a group in whom it has not been practical to study previously. Further study is necessary to determine whether these changes are significant in the presence of neuraxial anesthesia or in the high-risk parturient.

  2. Doppler ultrasonographic assessment of maternal and fetal arteries during normal feline gestation.

    PubMed

    Blanco, P G; Rodríguez, R; Olguín, S; Rube, A; Tórtora, M; Gobello, C

    2014-04-01

    The aim of this study was to describe Doppler parameters of uterine, umbilical, fetal abdominal aorta, fetal renal and fetal internal carotid arteries, as well as fetal heart rate (FHR), during normal feline gestation. Fifteen, 1-4 years of age, weighing 2.5-3.9kg, domestic short-hair pregnant queens, which were born in our institutional cat colony were included in this study. Color and pulsed-wave Doppler evaluations of uterine arteries were performed every 10 days (Day 0, 10, 20, 30, 40, 50, 60) from mating. Fetal Doppler and M-mode ultrasonography were performed to assess umbilical, fetal abdominal aorta, fetal renal, fetal internal carotid arteries and FHR. Both peak systolic velocity (PSV) and end diastolic velocity (EDV) of uterine artery increased up to parturition (P<0.01), while resistance index (RI) decreased from Day 10 onwards (P<0.01). From Day 40 onwards, RI of umbilical artery diminished, while PSV and EDV augmented (P<0.01). Fetal abdominal aorta (P<0.01), renal (P<0.01) and internal carotid (P<0.01) arteries diminished their RI from Days 40, 60 and 40 onwards, respectively. Both PSV and EDV of these three arteries increased progressively. Fetal heart rate was first registered on Day 20 when it began to increase up to Day 40 and then diminished to the end of gestation (P<0.01). It is concluded that blood flow of uterine, umbilical, fetal abdominal aorta, fetal renal and fetal internal carotid arteries progressively increased during normal feline pregnancy, while FHR rose to mid gestation and then decreased up to parturition. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Suture versus preperitoneal polypropylene mesh for elective umbilical hernia repairs.

    PubMed

    Berger, Rachel L; Li, Linda T; Hicks, Stephanie C; Liang, Mike K

    2014-12-01

    Repair of primary ventral hernias (PVH) such as umbilical hernias is a common surgical procedure. There is a paucity of risk-adjusted data comparing suture versus mesh repair of these hernias. We compared preperitoneal polypropylene (PP) repair versus suture repair for elective umbilical hernia repair. A retrospective review of all elective open PVH repairs at a single institution from 2000-2010 was performed. Only patients with suture or PP repair of umbilical hernias were included. Univariate analysis was conducted and propensity for treatment-adjusted multivariate logistic regression. There were 442 elective open PVH repairs performed; 392 met our inclusion criteria. Of these patients, 126 (32.1%) had a PP repair and 266 (67.9%) underwent suture repair. Median (range) follow-up was 60 mo (1-143). Patients who underwent PP repair had more surgical site infections (SSIs; 19.8% versus 7.9%, P < 0.01) and seromas (14.3% versus 4.1%, P < 0.01). There was no difference in recurrence (5.6% versus 7.5%, P = 0.53). On propensity score-adjusted multivariate analysis, we found that body mass index (odds ratio [OR], 1.10) and smoking status (OR, 2.3) were associated with recurrence. Mesh (OR, 2.34) and American Society of Anesthesiologists (OR, 1.95) were associated with SSI. Only mesh (OR, 3.41) was associated with seroma formation. Although there was a trend toward more recurrence with suture repair in our study, this was not statistically significant. Mesh repair was associated with more SSI and seromas. Further prospective randomized controlled trial is needed to clarify the role of suture and mesh repair in PVH. Copyright © 2014 Elsevier Inc. All rights reserved.

  4. Ultrasonography of umbilical structures in clinically normal foals.

    PubMed

    Reef, V B; Collatos, C

    1988-12-01

    The umbilical arteries, urachus, and umbilical vein were scanned ultrasonographically in 13 clinically normal foals that ranged in age from 6 hours to 4 weeks. Sonograms were obtained using a 7.5-MHz sector scanner transducer placed across the midline of the ventral portion of the foal's abdominal wall. The umbilical vein was scanned from the umbilical stalk to its entrance into the hepatic parenchyma. The mean (+/- SD) diameter of the umbilical vein was 0.61 +/- 0.20 cm immediately cranial to the umbilical stalk, 0.52 +/- 0.19 cm midway between the umbilicus and liver, and 0.6 +/- 0.19 cm at the liver. The urachus and umbilical arteries were scanned from the umbilical stalk to the apex of the urinary bladder and had a mean total diameter of 1.75 +/- 0.37 cm at the bladder apex. The umbilical arteries also were scanned along either side of the bladder and had a mean diameter of 0.85 +/- 0.21 cm. These measurements and the ultrasonographic appearance of the internal umbilical structures from clinically normal foals can be used as references to diagnose abnormalities of the umbilical structures in neonatal foals.

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Michael Viola, J. Edwards, T. Brown, L. Dudek, R. Ellis, P. Heitzenroeder, R. Strykowsky and Michael Cole

    The National Compact Stellarator Experiment (NCSX) was a collaborative effort between ORNL and PPPL. PPPL provided the assembly techniques with guidance from ORNL to meet design criteria. The individual vacuum vessel segments, modular coils, trim coils, and toroidal field coils components were delivered to the Field Period Assembly (FPA) crew who then would complete the component assemblies and then assemble the final three field period assemblies, each consisting of two sets of three modular coils assembled over a 120o vacuum vessel segment with the trim coils and toroidal field coils providing the outer layer. The requirements for positioning the modularmore » coils were found to be most demanding. The assembly tolerances required for accurate positioning of the field coil windings in order to generate sufficiently accurate magnetic fields strained state of the art techniques in metrology and alignment and required constant monitoring of assembly steps with laser trackers, measurement arms, and photogrammetry. The FPA activities were being performed concurrently while engineering challenges were being resolved. For example, it was determined that high friction electrically isolated shims were needed between the modular coil interface joints and low distortion welding was required in the nose region of those joints. This took months of analysis and development yet the assembly was not significantly impacted because other assembly tasks could be performed in parallel with ongoing assembly tasks as well as tasks such as advance tooling setup preparation for the eventual welding tasks. The crew technicians developed unique, accurate time saving techniques and tooling which provided significant cost and schedule savings. Project management displayed extraordinary foresight and every opportunity to gain advanced knowledge and develop techniques was taken advantage of. Despite many risk concerns, the cost and schedule performance index was maintained nearly 1.0 during the assembly phase until project cancellation. In this paper, the assembly logic, the engineering challenges, solutions to those challenges and some of the unique and clever assembly techniques, will be presented.« less

  6. [Umbilical endometriosis mimicking a keloid in a young black woman: A case report].

    PubMed

    Kourouma, H-S; Ecra, E-J; Allou, A-S; Kouyaté, M; Kouassi, Y-I; Kaloga, M; Kouassi, K-A; Kassi, K; Kouamé, K; Ahogo, C; Gbery, I-P; Sangaré, A

    2017-10-01

    Most umbilical tumors are diagnosed as benign tumors, umbilical metastases of abdominal and pelvic tumors, or Sister Marie Joseph nodule. Herein, we report a case of cutaneous umbilical endometriosis mistaken for a keloid. A young black woman aged 26 consulted for a painful umbilical tumefaction. She had noted the appearance of a nodule of the umbilicus 10 months ago with bleeding during her menstrual periods. Skin examination revealed a firm and painful umbilical nodule 2.5cm in diameter. She was treated with corticosteroid injections for one month for umbilical keloid. Given that the symptoms recurred regularly at the time of menstruation, we suspected umbilical endometriosis. This diagnosis was finally confirmed by histopathological examination and hormone therapy was instituted on gynecological advice before scheduled surgical excision. In a setting of an umbilical tumor simulating a keloid associated with cyclical symptoms in a black woman, the diagnosis of umbilical endometriosis should not be overlooked by the dermatologist. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  7. Umbilical hernia management during liver transplantation.

    PubMed

    de Goede, B; van Kempen, B J H; Polak, W G; de Knegt, R J; Schouten, J N L; Lange, J F; Tilanus, H W; Metselaar, H J; Kazemier, G

    2013-08-01

    Patients with liver cirrhosis scheduled for liver transplantation often present with a concurrent umbilical hernia. Optimal management of these patients is not clear. The objective of this study was to compare the outcomes of patients who underwent umbilical hernia correction during liver transplantation through a separate infra-umbilical incision with those who underwent correction through the same incision used to perform the liver transplantation. In the period between 1990 and 2011, all 27 patients with umbilical hernia and liver cirrhosis who underwent hernia correction during liver transplantation were identified in our hospital database. In 17 cases, umbilical hernia repair was performed through a separate infra-umbilical incision (separate incision group) and 10 were corrected from within the abdominal cavity without a separate incision (same incision group). Six patients died during follow-up; no deaths were attributable to intraoperative umbilical hernia repair. All 21 patients who were alive visited the outpatient clinic to detect recurrent umbilical hernia. One recurrent umbilical hernia was diagnosed in the separate incision group (6 %) and four (40 %) in the same incision group (p = 0.047). Two patients in the same incision group required repair of the recurrent umbilical hernia; one of whom underwent emergency surgery for bowel incarceration. The one recurrent hernia in the separate incision group was corrected electively. In the event of liver transplantation, umbilical hernia repair through a separate infra-umbilical incision is preferred over correction through the same incision used to perform the transplantation.

  8. Index formulas for higher order Loewner vector fields

    NASA Astrophysics Data System (ADS)

    Broad, Steven

    Let ∂ be the Cauchy-Riemann operator and f be a C real-valued function in a neighborhood of 0 in R in which ∂z¯nf≠0 for all z≠0. In such cases, ∂z¯nf is known as a Loewner vector field due to its connection with Loewner's conjecture that the index of such a vector field is bounded above by n. The n=2 case of Loewner's conjecture implies Carathéodory's conjecture that any C-immersion of S into R must have at least two umbilics. Recent work of F. Xavier produced a formula for computing the index of Loewner vector fields when n=2 using data about the Hessian of f. In this paper, we extend this result and establish an index formula for ∂z¯nf for all n⩾2. Structurally, our index formula provides a defect term, which contains geometric data extracted from Hessian-like objects associated with higher order derivatives of f.

  9. Abnormal arterial flows by a distributed model of the fetal circulation.

    PubMed

    van den Wijngaard, Jeroen P H M; Westerhof, Berend E; Faber, Dirk J; Ramsay, Margaret M; Westerhof, Nico; van Gemert, Martin J C

    2006-11-01

    Modeling the propagation of blood pressure and flow along the fetoplacental arterial tree may improve interpretation of abnormal flow velocity waveforms in fetuses. The current models, however, either do not include a wide range of gestational ages or do not account for variation in anatomical, vascular, or rheological parameters. We developed a mathematical model of the pulsating fetoumbilical arterial circulation using Womersley's oscillatory flow theory and viscoelastic arterial wall properties. Arterial flow waves are calculated at different arterial locations from which the pulsatility index (PI) can be determined. We varied blood viscosity, placental and brain resistances, placental compliance, heart rate, stiffness of the arterial wall, and length of the umbilical arteries. The PI increases in the umbilical artery and decreases in the cerebral arteries, as a result of increasing placental resistance or decreasing brain resistance. Both changes in resistance decrease the flow through the placenta. An increased arterial stiffness increases the PIs in the entire fetoplacental circulation. Blood viscosity and peripheral bed compliance have limited influence on the flow profiles. Bradycardia and tachycardia increase and decrease the PI in all arteries, respectively. Umbilical arterial length has limited influence on the PI but affects the mean arterial pressure at the placental cord insertion. The model may improve the interpretation of arterial flow pulsations and thus may advance both the understanding of pathophysiological processes and clinical management.

  10. Echocardiographic predictors of coil vs device closure in patients undergoing percutaneous patent ductus arteriosus closure.

    PubMed

    Roushdy, Alaa; Abd El Razek, Yasmeen; Mamdouh Tawfik, Ahmed

    2018-01-01

    To determine anatomic and hemodynamic echocardiographic predictors for patent ductus arteriosus (PDA) device vs coil closure. Seventy-six patients who were referred for elective transcatheter PDA closure were enrolled in the study. All patients underwent full echocardiogram including measurement of the PDA pulmonary end diameter, color flow width and extent, peak and end-diastolic Doppler gradients across the duct, diastolic flow reversal, left atrial dimensions and volume, left ventricular sphericity index, and volumes. The study group was subdivided into 2 subgroups based on the mode of PDA closure whether by coil (n = 42) or device (n = 34). Using univariate analysis there was a highly significant difference between the 2 groups as regard the pulmonary end diameter measured in both the suprasternal and parasternal short-axis views as well as the color flow width and color flow extent (P < .0001). The device closure group had statistically significant higher end-systolic and end-diastolic volumes indexed, left atrial volume, and diastolic flow reversal. Receiver operating characteristic curve analysis showed a pulmonary end diameter cutoff point from the suprasternal view > 2.5 mm and from parasternal short-axis view > 2.61 mm to have the highest balanced sensitivity and specificity to predict the likelihood for device closure (AUC 0.971 and 0.979 respectively). The pulmonary end diameter measured from the suprasternal view was the most independent predictor of device closure. The selection between PDA coil or device closure can be done on the basis of multiple anatomic and hemodynamic echocardiographic variables. © 2017 Wiley Periodicals, Inc.

  11. Troponin T and NT ProBNP Levels in Gestational, Type 1 and Type 2 Diabetic Mothers and Macrosomic Infants.

    PubMed

    Mert, Mustafa Kurthan; Satar, Mehmet; Özbarlas, Nazan; Yaman, Akgün; Özgünen, Fatma Tuncay; Asker, Hüseyin Selim; Çekinmez, Eren Kale; Tetiker, Tamer

    2016-01-01

    This study compares NT proBNP and troponin T levels in umbilical cord arterial blood and postnatal echocardiographic findings for infants of gestational and pregestational diabetic mothers and macrosomic infants. Twenty-seven infants of pregestational diabetic mothers, 61 infants of gestational diabetic mothers and 37 macrosomic infants of nondiabetic mothers were prospectively enrolled in this study along with a control group of 58 healthy infants of mothers without any pregestational or gestational disorders as the control group. All enrollees were born after 34 weeks of gestation. For this study, umbilical cord blood was drawn during delivery to determine NT proBNP and troponin T levels. Echocardiography was performed 24-72 h after the delivery. Umbilical cord troponin T and NT proBNP levels were found to be higher in the diabetic and macrosomic groups than in the control group (all of them p < 0.001). NT proBNP levels were positively correlated with interventricular septum thickness in the pregestational and gestational infants of diabetic mothers groups (r = 0.564 and r = 0.560, respectively, p < 0.01). Both pregestational and gestational diabetic mothers were divided into two groups according to HbA1c levels in the third trimester as good (<6.1 %) and suboptimal (>6.1 %) metabolic control. In the good and suboptimal metabolic control diabetic groups, NT proBNP levels were also positively correlated with interventricular septum thickness (r = 0.536 and r = 0.576, respectively, p < 0.01). In the suboptimal metabolic control diabetic group, NT proBNP was only found to be positively correlated with the left ventricular mass index (r = 0.586, p < 0.01). While there was no correlation in the myocardial performance index between infants of diabetic mothers and the control group, the myocardial performance index of macrosomic infants was lower than that of the control group (p = 0.017). Cardiac biomarkers (NT proBNP and troponin T) were elevated in infants of diabetic mothers and macrosomic infants. While there was a positive correlation between NT proBNP levels and cardiac structure in infants of pregestational and gestational diabetic mothers, there was no relationship between NT proBNP levels and cardiac function.

  12. [Expression and significance of adipocyte fatty acid-binding protein in placenta, serum and umbilical cord blood in preeclampsia].

    PubMed

    Yan, Jian-Ying; Wang, Xiao-Juan

    2010-12-01

    To investigate the change of adipocyte fatty acid-binding protein (FABP4) in maternal serum and umbilical cord blood and FABP4 mRNA placental expression in patients with preeclampsia (PE). A total of 60 women with PE and 60 normal pregnant women as control participated in this study.All are admitted to Fujian Maternity and Children Health Hospital for delivery from December 2008 to October 2009. Patients with PE were divided into early-onset group (n = 30, presented at ≤ 34 weeks of gestation) and late-onset group (n = 30, presented at > 34 weeks of gestation), with 30 normal pregnant women as early control group (≤ 34 weeks of gestation) and 30 as late control group (> 34 weeks of gestation). Enzyme-linked immunosorbent assay (ELISA) was used to detect FABP4, fasting serum glucose, fasting insulin (FINS) in maternal serum and FABP4 in umbilical cord blood. Real-time fluorescent quantitative reverse transcription PCR was used to detect placental FABP4 mRNA expression. Furthermore, clinical and biochemical parameters were recorded, such as body mass index (BMI), systolic pressure (SP), diastolic pressure (DP), mean arterial pressure (MAP), total cholesterol (TC), triglyceride (TG), low density lipoprotein (LDL), high density lipoprotein (HDL), creatinine (Cr), uric acid (UA), glomerular filtration rate (GFR), 24 hours urine protein in pregnant women and neonatal weight. (1) Maternal serum FABP4 was (176 ± 9) ng/L in early-onset PE group and (170 ± 9) ng/L in late-onset PE group, significantly elevated as compared to (81 ± 13) ng/L in early control group and (94 ± 15) ng/L in late control group. (2) Mean maternal FINS, homeostasis model of assessment for insulin resistence index (HOMA-IR) were significantly elevated in the early-onset PE group and late-onset PE group as compared to control groups, respectively. (3) Mean placental FABP4 mRNA expression were significantly elevated in the early-onset PE group and late-onset PE group as compared to late control group. However, no significant difference was found in placental FABP4 mRNA expression between early-onset and late-onset PE groups. (4) Mean umbilical cord blood FABP4 concentrations were significantly decreased in the early-onset PE group and late-onset PE group as compared to late control group. Furthermore, umbilical cord blood FABP4 concentration correlated negatively with maternal serum FABP4 level and placental FABP4 mRNA expression, but positively with neonatal weight. (5) Mean maternal serum FABP4 concentrations correlated positively with placental FABP4 mRNA expression, TG, FINS, HOMA-IR, Cr, UA; and negatively with HDL, GFR. Increased FABP4 expression in maternal serum and placenta may be involved in the pathogenesis of preeclampsia. Increased FABP4 mRNA expression in placenta may contribute to high serum FABP4 level in women with PE.

  13. Association of umbilical hernia with volume of ascites in liver cirrhosis: a retrospective observational study.

    PubMed

    Wang, Ran; Qi, Xingshun; Peng, Ying; Deng, Han; Li, Jing; Ning, Zheng; Dai, Junna; Hou, Feifei; Zhao, Jiancheng; Guo, Xiaozhong

    2016-11-01

    Umbilical hernia is a common abdominal complication in cirrhotic patients with ascites. Our study aimed to evaluate the correlation of umbilical hernia with the volume of ascites. Cirrhotic patients that underwent axial abdominopelvic computed tomography (CT) scans at our hospital between June 2012 and June 2014 were eligible. All CT images were reviewed to confirm the presence of umbilical hernia. The volume of ascites was estimated by five-point method. One hundred and fifty-seven patients were enrolled into this study. Among them, 101 patients had ascites and 6 patients had umbilical hernia. Alkaline phosphatase (AKP) and serum sodium were significantly lower in patients with umbilical hernia (P = 0.008, P = 0.011, respectively). Child-Pugh scores and the volume of ascites were significantly higher in patients with umbilical hernia (P = 0.03, P < 0.0001, respectively). Correlation analysis demonstrated that the volume of ascites, Child-Pugh scores, and blood ammonia had positive correlations with umbilical hernia (r = 0.4579, P < 0.0001; r = 0.175, P = 0.03; r = 0.342, P = 0.001, respectively) and that serum sodium had a negative correlation with umbilical hernia (r = -0.203, P = 0.011). In patients with ascites ≥2000 mL, only AKP was significantly associated with umbilical hernia (P = 0.0497). No variables were significantly associated with umbilical hernia in a subgroup analysis of patients matched according to the volume of ascites. The volume of ascites has a positive correlation with umbilical hernia. However, the factors associated with umbilical hernia in patients with severe ascites remain unclear. © 2016 Chinese Cochrane Center, West China Hospital of Sichuan University and John Wiley & Sons Australia, Ltd.

  14. Rare Abdominal Wall Malformation: Case Report of Umbilical Cord Hernia.

    PubMed

    Gliha, Andro; Car, Andrija; Višnjić, Stjepan; Zupancic, Bozidar; Kondza, Karmen; Petracic, Ivan

    The umbilical cord hernia is the rarest form of abdominal wall malformations, anatomically completely different from gastroschisis and omphalocele. It occurs due to the permanent physiological evisceration of abdominal organs into umbilical celom and persistence of a patent umbilical ring. The umbilical cord hernia is often mistaken for omphalocele and called "small omphalocele". Here we present a case of a female newborn with umbilical cord hernia treated in our Hospital. After preoperative examinations surgery was done on the second day of life. The abdominal wall was closed without tension. The aim of this article is to present the importance of the proper diagnose of these three entities and to stimulate academic community for the answer, is this umbilical cord hernia or small omphalocele.

  15. Stabilization of the vertical instability by non-axisymmetric coils

    DOE PAGES

    Turnbull, A. D.; Reiman, A. H.; Lao, L. L.; ...

    2016-07-05

    In a published Physical Review Letter [A. Reiman, Physical Review Letters, 99, 135007 (2007)], it was shown that axisymmetric (or vertical) stability can be improved by placing a set of parallelogram coils above and below the plasma oriented at an angle to the constant toroidal planes. The physics of this stabilization can be understood as providing an effective additional positive stability index. The original work was based on a simplified model of a straight tokamak and is not straightforwardly applicable to a finite aspect ratio, strongly shaped plasma such as in DIII-D. Numerical calculations were performed to provide a proofmore » of principal that 3-D fields can, in fact raise the elongation limits as predicted, in a real DIII-D-like configuration. A four field period trapezoid-shaped coil set was developed in toroidal geometry and 3-D equilibria were computed using trapezium coil currents of ,10kA, 100kA, and 500kA. The ideal magnetohydrodynamics growth rates were computed as a function of the conformal wall position for the n=0 symmetry-preserving family. The results show an insignificant relative improvement in the stabilizing wall location for the two lower coil current cases, of the order of 10 -3 and less. In contrast, the marginal wall position is increased by 7% as the coil current is increased to 500kA, confirming the main prediction from the original study in a real geometry case. In DIII-D the shift in marginal wall position of 7% would correspond to being able to move the existing wall outward by 5 to 10 cm. While the predicted effect on the axisymmetric stability is real, it appears to require higher coil currents than could be provided in an upgrade to existing facilities. Lastly, additional optimization over the pitch of the coils, the number of field periods and the coil positions, as well as plasma parameters, such as the internal inductivity l iβ, and q 95 would mitigate this but seem unlikely to change the conclusion.« less

  16. Stabilization of the vertical instability by non-axisymmetric coils

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Turnbull, A. D.; Reiman, A. H.; Lao, L. L.

    In a published Physical Review Letter [A. Reiman, Physical Review Letters, 99, 135007 (2007)], it was shown that axisymmetric (or vertical) stability can be improved by placing a set of parallelogram coils above and below the plasma oriented at an angle to the constant toroidal planes. The physics of this stabilization can be understood as providing an effective additional positive stability index. The original work was based on a simplified model of a straight tokamak and is not straightforwardly applicable to a finite aspect ratio, strongly shaped plasma such as in DIII-D. Numerical calculations were performed to provide a proofmore » of principal that 3-D fields can, in fact raise the elongation limits as predicted, in a real DIII-D-like configuration. A four field period trapezoid-shaped coil set was developed in toroidal geometry and 3-D equilibria were computed using trapezium coil currents of ,10kA, 100kA, and 500kA. The ideal magnetohydrodynamics growth rates were computed as a function of the conformal wall position for the n=0 symmetry-preserving family. The results show an insignificant relative improvement in the stabilizing wall location for the two lower coil current cases, of the order of 10 -3 and less. In contrast, the marginal wall position is increased by 7% as the coil current is increased to 500kA, confirming the main prediction from the original study in a real geometry case. In DIII-D the shift in marginal wall position of 7% would correspond to being able to move the existing wall outward by 5 to 10 cm. While the predicted effect on the axisymmetric stability is real, it appears to require higher coil currents than could be provided in an upgrade to existing facilities. Lastly, additional optimization over the pitch of the coils, the number of field periods and the coil positions, as well as plasma parameters, such as the internal inductivity l iβ, and q 95 would mitigate this but seem unlikely to change the conclusion.« less

  17. Stabilization of the vertical instability by non-axisymmetric coils

    NASA Astrophysics Data System (ADS)

    Turnbull, A. D.; Reiman, A. H.; Lao, L. L.; Cooper, W. A.; Ferraro, N. M.; Buttery, R. J.

    2016-08-01

    In a published Physical Review Letter (Reiman 2007 Phys. Rev. Lett. 99 135007), it was shown that axisymmetric (or vertical) stability can be improved by placing a set of parallelogram coils above and below the plasma oriented at an angle to the constant toroidal planes. The physics of this stabilization can be understood as providing an effective additional positive stability index. The original work was based on a simplified model of a straight tokamak and is not straightforwardly applicable to a finite aspect ratio, strongly shaped plasma such as in DIII-D. Numerical calculations were performed in a real DIII-D -like configuration to provide a proof of principal that 3-D fields can, in fact raise the elongation limits as predicted. A four field period trapezioid-shaped coil set was developed in toroidal geometry and 3D equilibria were computed using trapezium coil currents of 10 kA , 100 kA , and 500 kA . The ideal magnetohydrodynamics growth rates were computed as a function of the conformal wall position for the n = 0 symmetry-preserving family. The results show an insignificant relative improvement in the stabilizing wall location for the two lower coil current cases, of the order of 10-3 and less. In contrast, the marginal wall position is increased by 7% as the coil current is increased to 500 kA , confirming the main prediction from the original study in a real geometry case. In DIII-D the shift in marginal wall position of 7% would correspond to being able to move the existing wall outward by 5 to 10 cm. While the predicted effect on the axisymmetric stability is real, it appears to require higher coil currents than could be provided in an upgrade to existing facilities. Additional optimization over the pitch of the coils, the number of field periods and the coil positions, as well as plasma parameters, such as the internal inductivity {{\\ell}\\text{i}} , β , and {{q}95} would mitigate this but seem unlikely to change the conclusion.

  18. Reduced heart rate and cardiac output differentially affect angiogenesis, growth, and development in early chicken embryos (Gallus domesticus).

    PubMed

    Branum, Sylvia R; Yamada-Fisher, Miho; Burggren, Warren

    2013-01-01

    An increase in both vascular circumferential tension and shear stress in the developing vasculature of the chicken embryo has been hypothesized to stimulate angiogenesis in the developing peripheral circulation chorioallantoic membrane (CAM). To test this hypothesis, angiogenesis in the CAM, development, and growth were measured in the early chicken embryo, following acute and chronic topical application of the purely bradycardic drug ZD7288. At hour 56, ZD7288 reduced heart rate (f(H)) by ~30% but had no significant effect on stroke volume (~0.19 ± 0.2 μL), collectively resulting in a significant fall in cardiac output (CO) from ~27 ± 3 to 18 ± 2 μL min(-1). Mean f(H) at 72 h of development was similarly significantly lowered by acute ZD7288 treatment (250 μM) to 128 ± 0.3 beats min(-1), compared with 174.5 ± 0.3 and 174.7 ± 0.8 beats min(-1) in control and Pannett-Compton (P-C) saline-treated embryos, respectively. Chronic dosing with ZD7288-and the attendant decreases in f(H) and CO-did not change eye diameter or cervical flexion (key indicators of development rate) at 120 h but significantly reduced overall growth (wet and dry body mass decreased by 20%). CAM vessel density index (reflecting angiogenesis) measured 200-400 μm from the umbilical stalk was not altered, but ZD7288 reduced vessel numbers-and therefore vessel density-by 13%-16% more distally (500-600 μm from umbilical stalk) in the CAM. In the ZD7288-treated embryos, a decrease in vessel length was found within the second branch order (~300-400 μm from the umbilical stock), while a decrease in vessel diameter was found closer to the umbilical stock, beginning in the first branch order (~200-300 μm). Paradoxically, chronic application of P-C saline also reduced peripheral CAM vessel density index at 500 and 600 μm by 13% and 7%, respectively, likely from washout of local angiogenic factors. In summary, decreased f(H) with reduced CO did not slow development rate but reduced embryonic growth rate and angiogenesis in the CAM periphery. This study demonstrates for the first time that different processes in the ontogeny of the early vertebrate embryo (i.e., hypertrophic growth vs. development) have differential sensitivities to altered convective blood flow.

  19. Spatiotemporal image correlation-derived volumetric Doppler impedance indices from spherical samples of the placenta: intraobserver reliability and correlation with conventional umbilical artery Doppler indices.

    PubMed

    Welsh, A W; Hou, M; Meriki, N; Martins, W P

    2012-10-01

    Volumetric impedance indices derived from spatiotemporal image correlation (STIC) power Doppler ultrasound (PDU) might overcome the influence of machine settings and attenuation. We examined the feasibility of obtaining these indices from spherical samples of anterior placentas in healthy pregnancies, and assessed intraobserver reliability and correlation with conventional umbilical artery (UA) impedance indices. Uncomplicated singleton pregnancies with anterior placenta were included in the study. A single observer evaluated UA pulsatility index (PI), resistance index (RI) and systolic/diastolic ratio (S/D) and acquired three STIC-PDU datasets from the placenta just above the placental cord insertion. Another observer analyzed the STIC-PDU datasets using Virtual Organ Computer-aided AnaLysis (VOCAL) spherical samples from every frame to determine the vascularization index (VI) and vascularization flow index (VFI); maximum, minimum and average values were used to determine the three volumetric impedance indices (vPI, vRI, vS/D). Intraobserver reliability was examined by intraclass correlation coefficients (ICC) and association between volumetric indices from placenta, and UA Doppler indices were assessed by Pearson's correlation coefficient. A total of 25 pregnant women were evaluated but five were excluded because of artifacts observed during analysis. The reliability of measurement of volumetric indices of both VI and VFI from three STIC-PDU datasets was similar, with all ICCs ≥ 0.78. Pearson's r values showed a weak and non-significant correlation between UA pulsed-wave Doppler indices and their respective volumetric indices from spherical samples of placenta (all r ≥ 0.23). VOCAL indices from specific phases of the cardiac cycle showed good repeatability (ICC ≥ 0.92). Volumetric impedance indices determined from spherical samples of placenta are sufficiently reliable but do not correlate with UA Doppler indices in healthy pregnancies. Copyright © 2012 ISUOG. Published by John Wiley & Sons, Ltd.

  20. The changes in Doppler indices of fetal ductus venosus and umbilical artery after amnioinfusion for women with preterm premature rupture of membranes before 26 weeks' gestation.

    PubMed

    Hsu, Te-Yao; Hsu, Jenn-Jeih; Fu, Hung-Chun; Ou, Chia-Yu; Tsai, Chih-Chang; Cheng, Bi-Hua; Fang, Fu-Min; Kao, Hui-Fen; Yang, Chun-Yuh; Tsai, Wen Lin; Sung, Chuen Chu; Tsai, Men-Yi

    2009-09-01

    To investigate the changes in Doppler indices of the fetal ductus venosus (DV) and umbilical artery (UMA) after amnioinfusion in pregnant women with preterm premature rupture of membranes (pPROM). Pregnancies with pPROM and severe oligohydramnios cause sequelae in newborns and mothers. This cross-sectional study included a group of 25 patients with pPROM before 26 weeks' gestation. Color Doppler imaging was used to measure the impedance index and quantitative blood flow in the DV and systolic/diastolic ratio (S/D) of the UMA before and 30 minutes after the end of amnioinfusion. The following velocity parameters were measured: (1) DV peak systolic velocity; (2) DV time-averaged velocity; (3) DV maximum forward velocity during atrial contraction; (4) DV S/D; (5) DV pulsatility index (PI); (6) DV Pourcelots resistance index (RI); (7) fetal heart rate; and (8) UMA S/D. Twenty-one of the 25 patients underwent a total of 27 amnioinfusions. The mean PI and RI of the DV, and S/D of the DV and UMA decreased significantly after amnioinfusion (PI, 0.75 +/- 0.24 vs. 0.60 +/- 0.18, p = 0.009; RI, 0.60 +/- 0.15 vs. 0.50 +/- 0.13; DV S/D, 3.07 +/- 1.81 vs. 2.13 +/- 0.66, p = 0.008; UMA S/D, 3.58 +/- 0.87 vs. 2.88 +/- 0.62, p = 0.001). Amnioinfusion increases the space for the fetuses and reduces the impedance of the fetoplacental circulation. Improvements in DV and UMA flow may benefit fetuses suffering severe oligohydramnios in mid-pregnancy.

  1. 46. BASE OF UMBILICAL MAST FROM UMBILICAL MAST TRENCH. ERECTION ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    46. BASE OF UMBILICAL MAST FROM UMBILICAL MAST TRENCH. ERECTION AND RETRACTION CYLINDERS BETWEEN MAST AND TRENCH WALL. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 East, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  2. Incarceration of a pedunculated uterine fibroid in an umbilical hernia.

    PubMed

    Kim, Mi Ju; Cha, Hyun-Hwa; Seong, Won Joon

    2017-05-01

    Uterine fibroids are common benign tumors that may cause an umbilical hernia in patients with increased intra-abdominal pressure due to pregnancy, obesity, ascites, and intra-abdominal tumors. However, the simultaneous occurrence of uterine fibroids and umbilical hernias, or fibroids and an associated umbilical hernia, during pregnancy has rarely been reported. Here, we present the case of a fibroid presenting as an incarcerated umbilical hernia in a menopausal patient.

  3. Poorly understood and often miscategorized congenital umbilical cord hernia: an alternative repair method.

    PubMed

    İnce, E; Temiz, A; Ezer, S S; Gezer, H Ö; Hiçsönmez, A

    2017-06-01

    Umbilical cord hernia is poorly understood and often miscategorized as "omphalocele minor". Careless clamping of the cord leads to iatrogenic gut injury in the situation of umbilical cord hernia. This study aimed to determine the characteristics and outcomes of umbilical cord hernias. We also highlight an alternative repair method for umbilical cord hernias. We recorded 15 cases of umbilical cord hernias over 10 years. The patients' data were retrospectively reviewed, and preoperative preparation of the newborn, gestational age, birth weight, other associated malformations, surgical technique used, enteral nutrition, and length of hospitalization were recorded. This study included 15 neonates with umbilical cord hernias. The mean gestational age at the time of referral was 38.2 ± 2.1

  4. Incarceration of a pedunculated uterine fibroid in an umbilical hernia

    PubMed Central

    Kim, Mi Ju; Seong, Won Joon

    2017-01-01

    Uterine fibroids are common benign tumors that may cause an umbilical hernia in patients with increased intra-abdominal pressure due to pregnancy, obesity, ascites, and intra-abdominal tumors. However, the simultaneous occurrence of uterine fibroids and umbilical hernias, or fibroids and an associated umbilical hernia, during pregnancy has rarely been reported. Here, we present the case of a fibroid presenting as an incarcerated umbilical hernia in a menopausal patient. PMID:28534020

  5. Deformation and Flexibility Equations for Idealized ARIS Umbilicals, Under Planar End-Loading Conditions

    NASA Technical Reports Server (NTRS)

    Hampton, R. David; Quraishi, Naveed (Technical Monitor)

    2003-01-01

    The International Space Station (ISS) relies on the Active Rack Isolation System (ARIS) as the central component of an integrated, station-wide strategy to isolate microgravity space-science experiments. ARIS uses electromechanical actuators to isolate an International Standard Payload Rack (ISPR) from disturbances due to the motion of the ISS. Disturbances to microgravity experiments on ARIS-isolated racks are primarily transmitted via the ARTS power and vacuum umbilicals. Recent experimental tests indicate that these umbilicals resonate at frequencies outside the ARIS controller's bandwidth, at levels of potential concern for certain microgravity experiments. Reduction in the umbilical resonant frequencies could help to address this issue. This report develops equations for the in-plane deflections and flexibilities of an idealized umbilical (thin, flexible, cantilever beam) under end-point, in-plane loading (inclined-force and moment). The effect of gravity is neglected due to the on-orbit application. The analysis assumes an initially straight, cantilevered umbilical with uniform cross-section, which undergoes large deflections with no plastic deformation, such that the umbilical terminus remains in a single quadrant and the umbilical slope changes monotonically. The analysis is applicable to the ARIS power and vacuum umbilicals, under the indicated assumptions.

  6. Deformation and Flexibility Equations for Idealized ARIS Umbilicals, Under Planar End-Loading Conditions

    NASA Technical Reports Server (NTRS)

    Hampton, R. David; Quraishi, Naveed; Rupert, Jason K.

    2000-01-01

    The International Space Station (ISS) relies on the Active Rack Isolation System (ARIS) as the central component of an integrated, station-wide strategy to isolate microgravity space-science experiments. ARIS uses electromechanical actuators to isolate an International Standard Payload Rack (ISPR) from disturbances due to the motion of the ISS. Disturbances to microgravity experiments on ARIS-isolated racks are primarily transmitted via the ARIS power and vacuum umbilicals. Recent experimental tests indicate that these umbilicals resonate at frequencies outside the ARIS controller's bandwidth. at levels of potential concern for certain microgravity experiments. Reduction in the umbilical resonant frequencies could help to address this issue. This paper develops equations for the in-plane deflections and flexibilities of an idealized umbilical (thin, flexible, cantilever beam) under end-point, in-plane loading (inclined-force and moment). The effect of gravity is neglected due to the on:orbit application. The analysis assumes an initially straight. cantilevered umbilical with uniform cross-section. which undergoes large deflections with no plastic deformation, such that the umbilical terminus remains in a single quadrant and the umbilical slope changes monotonically. The analysis is applicable to the ARIS power and vacuum umbilicals. under the indicated assumptions.

  7. Automated Ground Umbilical Systems (AGUS) Project

    NASA Technical Reports Server (NTRS)

    Gosselin, Armand M.

    2007-01-01

    All space vehicles require ground umbilical systems for servicing. Servicing requirements can include, but are not limited to, electrical power and control, propellant loading and venting, pneumatic system supply, hazard gas detection and purging as well as systems checkout capabilities. Of the various types of umbilicals, all require several common subsystems. These typically include an alignment system, mating and locking system, fluid connectors, electrical connectors and control !checkout systems. These systems have been designed to various levels of detail based on the needs for manual and/or automation requirements. The Automated Ground Umbilical Systems (AGUS) project is a multi-phase initiative to develop design performance requirements and concepts for launch system umbilicals. The automation aspect minimizes operational time and labor in ground umbilical processing while maintaining reliability. This current phase of the project reviews the design, development, testing and operations of ground umbilicals built for the Saturn, Shuttle, X-33 and Atlas V programs. Based on the design and operations lessons learned from these systems, umbilicals can be optimized for specific applications. The product of this study is a document containing details of existing systems and requirements for future automated umbilical systems with emphasis on design-for-operations (DFO).

  8. Signs of fetal brain sparing are not related to umbilical cord blood gases at birth.

    PubMed

    Cheema, Riffat; Dubiel, Mariusz; Gudmundsson, Saemundur

    2009-07-01

    Fetal chronic hypoxia leads to centralization of circulation in order to spare the vital organs brain, adrenals and the heart. This can be documented by Doppler ultrasound. Increased blood velocity in the fetal middle cerebral artery (MCA) is an acknowledged sign of centralization of circulation in chronic hypoxia, and is called brain sparing. Our aim was to assess the relationship between signs of brain sparing in the MCA and umbilical cord blood gases at birth. A prospective study. Singleton 57 high-risk pregnancies (outcome was compared with 21 normal pregnancies). MCA Doppler was performed within 24 h of elective caesarean section in high-risk pregnancies. Umbilical cord blood gases were analysed at birth. Cord blood gases were related to signs of centralization of fetal circulation in the MCA. No correlation between signs of brain sparing in the MCA and cord blood gases. Apgar score at 5'<7 was seen in three newborns, but only one of these had antenatal signs of brain sparing. Newborns with antenatal brain sparing were admitted more often (p<0.04) and had a longer duration of stay in NICU (p<0.03) compared to newborns without brain sparing. Decreased pulsatility index in MCA is an acknowledged sign of fetal centralization of circulation during chronic hypoxia. However, signs of brain sparing are not related to cord blood gases at birth, which might suggest that redistribution of fetal circulation can maintain normal blood gases for a long time during chronic hypoxia.

  9. Maternal Serum Endocan Concentration in Pregnancies Complicated by Intrauterine Growth Restriction.

    PubMed

    Szpera-Gozdziewicz, Agata; Kosicka, Katarzyna; Gozdziewicz, Tomasz; Krzyscin, Mariola; Wirstlein, Przemyslaw; Siemiatkowska, Anna; Glowka, Franciszek; Wender-Ozegowska, Ewa; Breborowicz, Grzegorz H

    2018-01-01

    Endocan plays a role in the development of vascular tissue in health and disease and is an indicator of endothelial cells activation and angiogenesis. Therefore, this study aimed to investigate the relationship between maternal endocan serum level and intrauterine growth restriction (IUGR) as well as ultrasound Doppler flow measurements indicating placental insufficiency. This study included a group of women with IUGR (n = 37) and a group of healthy pregnant women (controls, n = 37). The endocan serum concentrations were assessed using commercially available enzyme-linked immunosorbent assay kit. Every woman underwent an ultrasound examination with Doppler flow measurements of the uterine arteries, umbilical vessels, and fetal middle cerebral artery. We used the cerebroplacental ratio (CPR) to determine placental insufficiency. We found significant differences in median (interquartile) endocan serum level (pg/mL) between study and control groups (464 [374-532] vs 339 [189-496], respectively; P < .001). The endocan serum level correlated neither with umbilical cord blood gases nor with Apgar score. Ultrasound Doppler findings revealed significant differences in middle cerebral artery pulsatility index (PI), umbilical artery PI, CPR, as well as mean uterine arteries PI between IUGR group and controls. In the study group, we found significant correlations between the serum endocan and CPR ( R = 0.56, P < .001) as well as between serum endocan and mean uterine arteries PI ( R = 0.46, P = .006). Endocan is likely involved in the pathogenesis of IUGR in pregnant women and possibly is a useful marker of endothelial dysfunction in these cases.

  10. Umbilical hernia repair in pregnant patients: review of the American College of Surgeons National Surgical Quality Improvement Program.

    PubMed

    Haskins, I N; Rosen, M J; Prabhu, A S; Amdur, R L; Rosenblatt, S; Brody, F; Krpata, D M

    2017-10-01

    Umbilical hernias present commonly during pregnancy secondary to increased intra-abdominal pressure. As a result, umbilical hernia incarceration or strangulation may affect pregnant females. The purpose of this study is to detail the operative management and 30-day outcomes of umbilical hernias in pregnant patients using the American College of Surgeons National Surgical Quality Improvement Program (ACS-NSQIP). All female patients undergoing umbilical hernia repair during pregnancy were identified within the ACS-NSQIP. Preoperative patient variables, intraoperative variables, and 30-day patient morbidity and mortality outcomes were investigated using a variety of statistical tests. A total of 126 pregnant patients underwent umbilical hernia repair from 2005 to 2014; 73 (58%) had incarceration or strangulation at the time of surgical intervention. The majority of patients (95%) underwent open umbilical hernia repair. Superficial surgical site infection was the most common morbidity in patients undergoing open umbilical hernia repair. Based on review of the ACS-NSQIP database, the incidence of umbilical hernia repair during pregnancy is very low; however, the majority of patients required repair for incarceration of strangulation. When symptoms develop, these hernias can be repaired with minimal 30-day morbidity to the mother. Additional studies are needed to determine the long-term recurrence rate of umbilical hernia repairs performed in pregnant patients and the effects of surgical intervention and approach on the fetus.

  11. Nutritional status and umbilical hernia in Nigerian school children of different ethnic groups.

    PubMed Central

    Ebomoyi, E.; Parakoyi, D. B.; Omonisi, M. K.

    1991-01-01

    The relationship between nutritional status and umbilical hernia was assessed among Hausa and Yoruba school children in rural areas of Kwara State, Nigeria. The prevalence of umbilical hernia in the rural school pupils was 19.4%. The Yoruba school children had a higher prevalence rate of 22.0%, while the prevalence rate for Hausa pupils was 16.9%. The association between umbilical hernia and primary school class was statistically significant. More school children suffering from protein energy malnutrition presented with umbilical hernia. The association between umbilical hernia and nutritional status was weak. The school health component of the national primary health program should be intensified to screen school children regularly for umbilical hernia. The school health environment of rural Nigerian schools should be improved through government efforts. Images Figure 1 Figure 2 PMID:1800766

  12. Umbilical paracentesis for incarcerated umbilical hernia in patients with end-stage liver disease.

    PubMed

    Alonso, S; Donat, M; Carrion, L; Rodriguez, J M; Diego, L; Acin, D; Serrano, A; Perez, E; Pereira, F

    2016-08-01

    Patients with cirrhosis and ascites are prone to abdominal wall complications largely predominate by umbilical hernia. Elective surgery is indicated in select patients but a high morbidity and mortality rate occurs if it is performed in emergency conditions. We present a clinical case of a patient with advanced alcoholic liver disease who came to the emergency room for an acutely incarcerated umbilical hernia. Due to the high surgical risk, we had to discuss other treatment options. The use of umbilical paracentesis for incarcerated hernia reduction in cirrhotic patients with tense ascites is a safe and reproducible technique. Umbilical paracentesis could be considered as an alternative to emergency surgery in these high-risk patients.

  13. Spontaneous Endometriosis Within a Primary Umbilical Hernia

    PubMed Central

    Yheulon, Christopher G

    2017-01-01

    Umbilical hernias are rather common in the General Surgery clinic; however, endometriosis of an umbilical hernia is rare. It is especially unusual to have endometriosis of an umbilical hernia spontaneously occur compared to occurring at a site of a prior surgery. We present a case of spontaneous endometriosis of an umbilical hernia without prior surgery to her umbilicus. She had not presented with the usual symptoms of endometriosis and it was not considered as a diagnosis prior to surgery. Umbilical endometriosis is rare but usually occurs after prior laparoscopic surgery. We believe this is the second reported case in the English literature and the first such case reported from North America of spontaneous endometriosis of an umbilical hernia. This case highlights the importance of a full review of systems and qualifying the type and occurrence of pain. Additionally, it is always important to analyze surgical specimens in pathology to avoid errors in diagnosis. PMID:29164008

  14. Spontaneous Endometriosis Within a Primary Umbilical Hernia.

    PubMed

    Laferriere, Nicole R; Yheulon, Christopher G

    2017-11-01

    Umbilical hernias are rather common in the General Surgery clinic; however, endometriosis of an umbilical hernia is rare. It is especially unusual to have endometriosis of an umbilical hernia spontaneously occur compared to occurring at a site of a prior surgery. We present a case of spontaneous endometriosis of an umbilical hernia without prior surgery to her umbilicus. She had not presented with the usual symptoms of endometriosis and it was not considered as a diagnosis prior to surgery. Umbilical endometriosis is rare but usually occurs after prior laparoscopic surgery. We believe this is the second reported case in the English literature and the first such case reported from North America of spontaneous endometriosis of an umbilical hernia. This case highlights the importance of a full review of systems and qualifying the type and occurrence of pain. Additionally, it is always important to analyze surgical specimens in pathology to avoid errors in diagnosis.

  15. Functional magnetic resonance imaging and transcranial magnetic stimulation: effects of motor imagery, movement and coil orientation.

    PubMed

    Niyazov, D M; Butler, A J; Kadah, Y M; Epstein, C M; Hu, X P

    2005-07-01

    To compare fMRI activations during movement and motor imagery to corresponding motor evoked potential (MEP) maps obtained with the TMS coil in three different orientations. fMRI activations during executed (EM) and imagined (IM) movements of the index finger were compared to MEP maps of the first dorsal interosseus (FDI) muscle obtained with the TMS coil in anterior, posterior and lateral handle positions. To ensure spatial registration of fMRI and MEP maps, a special grid was used in both experiments. No statistically significant difference was found between the TMS centers of gravity (TMS CoG) obtained with the three coil orientations. There was a significant difference between fMRI centers of gravity during IMs (IM CoG) and EMs (EM CoG), with IM CoGs localized on average 10.3mm anterior to those of EMs in the precentral gyrus. Most importantly, the IM CoGs closely matched cortical projections of the TMS CoGs while the EM CoGs were on average 9.5mm posterior to the projected TMS CoGs. TMS motor maps are more congruent with fMRI activations during motor imagery than those during EMs. These findings are not significantly affected by changing orientation of the TMS coil. Our results suggest that the discrepancy between fMRI and TMS motor maps may be largely due to involvement of the somatosensory component in the EM task.

  16. Neonatal oxidative stress depends on oxygen blood pressure in umbilical artery.

    PubMed

    Proietti, F; De Bernardo, G; Longini, M; Sordino, D; Scaramuzzini, G; Tataranno, M L; Belvisi, E; Bazzini, F; Perrone, S; Buonocore, G

    2016-01-01

    With advancing gestation, partial pressure of oxygen (pO2) and pH fall significantly. Hypoxia is a main factor inducing free radical generation and thereby oxidative stress (OS). Placental and fetal tissue response when oxygen becomes restricted is complex and partially known. We tested the hypothesis that changes in umbilical artery and vein blood gas concentrations modulate OS occurrence in the newborn. Seventy umbilical artery and vein plasma samples were collected from healthy term newborns immediately after delivery. F2 Isoprostanes (F2-Isop) were measured in all samples as reliable markers of lipid peroxidation. Significantly lower pCO2 and higher pO2 and pH were found in umbilical vein than in artery, as expected. A positive correlation was detected between pH and pO2 only in umbilical artery (p=0.019). F2-Isop levels were no different between artery and vein in cord blood. Significant correlations were found between F2-Isop and pCO2 (p=0.025) as well as between F2-Isop and pH in umbilical vein (p=0.027). F2-Isop correlated with pCO2 (p=0.007) as well as with pO2 values (p=0.005) in umbilical artery blood. Oxidative stress (OS) in newborns depends on oxygen concentrations in umbilical artery. OS biomarkers significantly correlate with pO2 and in umbilical artery but not in umbilical vein. In normoxic conditions fetal-maternal gas exchanges occurring in placenta re-establish normal higher oxygen levels in umbilical vein than artery, with a normal production of free radicals without any deleterious effects.

  17. Umbilical Cord Mesenchymal Stem Cell Treatment for Crohn’s Disease: A Randomized Controlled Clinical Trial

    PubMed Central

    Zhang, Jian; Lv, Samei; Liu, Xiaojing; Song, Bin; Shi, Liping

    2018-01-01

    Background/Aims Stem cell therapy has been applied to treat a variety of autoimmune diseases, including Crohn’s disease (CD), but few studies have examined the use of umbilical cord mesenchymal stem cells (UC-MSCs). This trial sought to investigate the efficacy and safety of UC-MSCs for the treatment of CD. Methods Eighty-two patients who had been diagnosed with CD and had received steroid maintenance therapy for more than 6 months were included in this study. Forty-one patients were randomly selected to receive a total of four peripheral intravenous infusions of 1×106 UC-MSCs/kg, with one infusion per week. Patients were followed up for 12 months. The Crohn’s disease activity index (CDAI), Harvey-Bradshaw index (HBI), and corticosteroid dosage were assessed. Results Twelve months after treatment, the CDAI, HBI, and corticosteroid dosage had decreased by 62.5±23.2, 3.4±1.2, and 4.2±0.84 mg/day, respectively, in the UC-MSC group and by 23.6±12.4, 1.2±0.58, and 1.2±0.35 mg/day, respectively, in the control group (p<0.01, p<0.05, and p<0.05 for UC-MSC vs control, respectively). Four patients developed a fever after cell infusion. No serious adverse events were observed. Conclusions UC-MSCs were effective in the treatment of CD and produced mild side effects. PMID:28873511

  18. Discordant Umbilical Cord Drug Testing Results in Monozygotic Twins.

    PubMed

    Alexander, Amy; Abbas, Liaqat; Jones, Mary; Jones, Joseph; Lewis, Douglas; Negrusz, Adam

    2018-06-01

    Our laboratory received segments of umbilical cord that originated from identical twins for routine toxicology analysis. The specimens were analyzed multiple times by liquid chromatography tandem mass spectrometry. The umbilical cord from newborn #1 was positive for hydromorphone only (1.06 ng/g), and the umbilical cord from newborn #2 was positive for hydromorphone (0.81 ng/g) and benzoylecgonine (5.41 ng/g). The hydromorphone results are consistent with maternal administration of hydromorphone; however, the cause of the discrepant benzoylecgonine results in the umbilical cords from the identical twins is unknown.

  19. Catamenial Pain in Umbilical Hernia with Spontaneous Reduction: An Unusual Presentation of a Rare Entity.

    PubMed

    Pandey, Divya; Sharma, Ritu; Salhan, Sudha

    2015-08-01

    Spontaneous umbilical endometriosis occurring in absence of any previous abdominal or uterine surgery is extremely atypical. Its association with umbilical hernia is very rare and hernia getting spontaneously resolved has not been reported in literature so far. Here we report a case of a patient with spontaneous umbilical endometriosis associated with umbilical hernia which led to spontaneous hernia reduction. This was also associated with multiple uterine fibromyoma and bilateral ovarian endometrioma which were simultaneously treated by total abdominal hysterectomy with bilateral salpingo-oopherectomy along with surgical excision of the endometriotic tissue and repair of the abdominal wall defect. To the best of our knowledge, this is the first described case of spontaneous umbilical hernia reduction due to development of endometriosis.

  20. High-Frequency Ultrasound for the Study of Early Mouse Embryonic Cardiovascular System.

    PubMed

    Greco, Adelaide; Coda, Anna Rita Daniela; Albanese, Sandra; Ragucci, Monica; Liuzzi, Raffaele; Auletta, Luigi; Gargiulo, Sara; Lamagna, Francesco; Salvatore, Marco; Mancini, Marcello

    2015-12-01

    An accurate diagnosis of congenital heart defects during fetal development is critical for interventional planning. Mice can be used to generate animal models with heart defects, and high-frequency ultrasound (HFUS) imaging enables in utero imaging of live mouse embryos. A wide range of physiological measurements is possible using Doppler-HFUS imaging; limitations of any single measurement warrant a multiparameter approach to characterize cardiovascular function. Doppler-HFUS was used to explore the embryonic (heart, aorta) and extraembryonic (umbilical blood flow) circulatory systems to create a database in normal mouse embryos between 9.5 and 16.5 days of gestation. Multivariate analyses were performed to explore correlations between gestational age and embryo echocardiographic parameters. Heart rate and peak velocity in the aorta were positively correlated with gestational time, whereas cardiac cycle length, isovolumetric relaxation time, myocardial performance index, and arterial deceleration time of the umbilical cord were negatively correlated with it. Doppler-HFUS facilitated detailed characterization of the embryonic mouse circulation and represents a useful tool for investigation of the early mouse embryonic cardiovascular system. © The Author(s) 2015.

  1. Surgical anatomy and morphologic variations of umbilical structures.

    PubMed

    Fathi, Amir H; Soltanian, Hooman; Saber, Alan A

    2012-05-01

    The umbilicus is the main access route to the abdominal cavity in laparoscopic surgeries. However, its anatomical configuration is rarely studied in the surgical and anatomical literature. With introduction of laparoendoscopic single-site surgery and considering the significant number of primary and postoperative umbilical hernias, we felt the necessity to comprehensively study the umbilical structures and analyze their protective function against hernias. Twenty-four embalmed cadavers were studied in the anatomy laboratory of Case Western Reserve University. Round hepatic, median and medial ligaments, umbilical ring, umbilical and umbilicovesicular fasciae, and pattern of attachment to the ring were dissected and measured. Mean age was 82.1 years, ranging between 56 and 96 years, with a male-to-female ratio of 1.4:1. Ninety-two per cent was white and 8 per cent black adults. According to shape and attachment pattern of ligaments, umbilical ring is classified into five types. Hernia incidence was 25 per cent. All hernia cases lacked the umbilical fascia and the round hepatic ligament was not attached to the inferior border of the ring. The umbilical ring and its morphologic relation with adjacent ligaments are described and classified into five types. In contrary to sparse existing literature, we propose that umbilical fascia is continuation and condensation of umbilicovesicular rather than transversalis fascia. It was absent in cadavers forming conjoined median and medial ligaments with a single insertion site to the ring. Round ligament insertion to the inferior border of the ring provides another protective factor. These two protective measures were absent in all the observed umbilical hernias.

  2. Umbilical scarring in hatchling American alligators

    USGS Publications Warehouse

    Wiebe, J.J.; Sepulveda, M.S.; Buckland, J.E.; Anderson, S.R.; Gross, T.S.

    2004-01-01

    Umbilical scarring is the presence of excess scar tissue deposited between abdominal dermal layers at the site of yolk sac absorption in hatchling American alligators (Alligator mississippiensis). The presence of this dermal condition plays a key evaluatory role in the overall quality and subsequent value for various commercial leather products. Despite the prevalent nature of this condition, currently the industry has no standardized protocols for its quantification. The objectives of this study were to examine the relationship between hatchling weight and age and incidence of umbilical scarring and to develop a quantifiable and reproducible technique to measure this dermal condition in hatchling American alligators. Thirty eggs from each of nine clutches were incubated in two separate incubators at different facilities and hatchling umbilical scarring was measured at 2 and 10 days of age using digital calipers. Umbilical area was calculated by multiplying umbilical length times umbilical width. There was a significant effect of both age and clutch on umbilical area (overall decline of 64%) by 10 days post-hatch. However, only five of the nine clutches utilized expressed a noticeable decline in the size of this dermal condition (range 67-74%). We had hypothesized that larger hatchlings would have larger umbilical areas and a slower rate of improvement in this condition during the first few days post-hatch. The differences in umbilical area and percent decline with age across clutches, however, were not associated with differences in initial hatchling weights. Within clutches and time periods, hatchling weight had no significant effect on the size and/or rate of decline of this condition. ?? 2004 Published by Elsevier B.V.

  3. Deformation and Flexibility Equations for ARIS Umbilicals Idealized as Planar Elastica

    NASA Technical Reports Server (NTRS)

    Hampton, R. David; Leamy, Michael J.; Bryant, Paul J.; Quraishi, Naveed

    2005-01-01

    The International Space Station relies on the active rack isolation system (ARIS) as the central component of an integrated, stationwide strategy to isolate microgravity space-science experiments. ARIS uses electromechanical actuators to isolate an international standard payload rack from disturbances due to the motion of the Space Station. Disturbances to microgravity experiments on ARIS isolated racks are transmitted primarily via the ARIS power and vacuum umbilicals. Experimental tests indicate that these umbilicals resonate at frequencies outside the ARIS controller s bandwidth at levels of potential concern for certain microgravity experiments. Reduction in the umbilical resonant frequencies could help to address this issue. This work documents the development and verification of equations for the in-plane deflections and flexibilities of an idealized umbilical (thin, flexible, inextensible, cantilever beam) under end-point, in-plane loading (inclined-force and moment). The effect of gravity is neglected due to the on-orbit application. The analysis assumes an initially curved (not necessarily circular), cantilevered umbilical with uniform cross-section, which undergoes large deflections with no plastic deformation, such that the umbilical slope changes monotonically. The treatment is applicable to the ARIS power and vacuum umbilicals under the indicated assumptions.

  4. The Development and Implementation of the Kennedy Space Center Umbilical Clearance Tool

    NASA Technical Reports Server (NTRS)

    Chesnutt, David

    2016-01-01

    In preparation for NASAs upcoming Space Launch System program, the Kennedy Space Center is currently developing subsystems to provide fuel, purges and communications to the flight vehicle, known as umbilicals. It is vital to the crew and mission that these umbilicals release at T-0 without re-contacting the vehicle as it is accelerating from the launch pad. To help ensure this requirement is met by the program, a methodology of evaluating the moving bodies was developed and implemented into a tool using MATLAB. The tool, known as the KSC Umbilical Clearance Tool, takes a given elevation of interest and an umbilical retract profile within the plane to evaluate the clearance between the umbilical arm and thousands of independent flight vehicle drift profiles from a Monte Carlo analysis. The presentation will delve into the challenges associated with developing and implementing the tool framed in the context of evaluating the clearance for one of the SLS umbilicals.

  5. [Intestinal polyp of the umbilical cord].

    PubMed

    Guschmann, M; Janda, J; Wenzelides, K; Vogel, M

    2002-02-01

    The morphology, pathogenesis, complications and differential diagnosis of an intestinal polyp of the umbilical cord are presented. The polyp were detected postnatal on the umbilical cord in an healthy male newborn. The presents of intestinal tissue upon the umbilical cord ist possible about the persistence from remnants of the ductus omphalomesentericus with prolapse and differentiation of the intestinal cells. The ductus omphalomesentericus is a tubular structure, a communication between the developing embryonic gut and the yolk sac, forming during the early embryonic life. Obliteration of the omphalomesenteric duct is usually complete by the 10(th) week of gestation. Various portions of the duct may persist, however, giving rise to polyps, fistulas or cysts of the umbilical cord with potentially dangerous clinical consequences. Other tumors of the umbilical cord are myxoma, angioma and teratoma are differential diagnosis.

  6. [Umbilical hernia repair in conjunction with abdominoplasty].

    PubMed

    Bai, Ming; Dai, Meng-Hua; Huang, Jiu-Zuo; Qi, Zheng; Lin, Chen; Ding, Wen-Yun; Zhao, Ru

    2012-09-01

    To investigate the feasibility and clinical benefits of umbilical hernia repair in conjunction with abdominoplasty. The incision was designed in accord with abdominoplasty. The skin and subcutaneous tissue was dissected toward the costal arch, and then the anterior sheath of rectus abdominus was exposed. After exposure and dissection of the sac of umbilical hernia, tension-free hernioplasty was performed with polypropylene mesh. After dissecting the redundant skin and subcutaneous tissue, the abdominal wall was tightened. Between May 2008 and May 2011, ten patients were treated in the way mentioned above. The repair of umbilical hernia and the correction of abdominal wall laxity were satisfactory. There was no recurrence of umbilical hernia, hematoma, seroma or fat liquefaction. Through careful selection of patients, repair of umbilical hernia and body contouring could be achieved simultaneously.

  7. Therapy of umbilical hernia during laparoscopic cholecystectomy.

    PubMed

    Zoricić, Ivan; Vukusić, Darko; Rasić, Zarko; Schwarz, Dragan; Sever, Marko

    2013-09-01

    The aim of this study is to show our experience with umbilical hernia herniorrhaphy and laparoscopic cholecystectomy, both in the same act. During last 10 years we operated 89 patients with cholecystitis and pre-existing umbilical hernia. In 61 of them we performed standard laparoscopic cholecystectomy and additional sutures of abdominal wall, and in 28 patients we performed in the same act laparoscopic cholecystectomy and herniorrhaphy of umbilical hernia. We observed incidence of postoperative herniation, and compared patients recovery after herniorrhaphy combined with laparoscopic cholecystectomy in the same act, and patients after standard laparoscopic cholecystectomy and additional sutures of abdominal wall. Patients, who had in the same time umbilical hernia herniorrhaphy and laparoscopic cholecystectomy, shown better postoperative recovery and lower incidence of postoperative umbilical hernias then patients with standard laparoscopic cholecystectomy and additional abdominal wall sutures.

  8. Umbilical hernia masking primary umbilical endometriosis - a case report.

    PubMed

    Brătilă, Elvira; Ionescu, Oana Maria; Badiu, Dumitru Cristinel; Berceanu, Costin; Vlădăreanu, Simona; Pop, Doina Mihaela; MehedinŢu, Claudia

    2016-01-01

    Endometriosis is a gynecologic condition affecting mainly the pelvic organs. However, extrapelvic endometriosis has been reported in almost all parts of the body. Umbilical endometriosis, either primary or secondary, is uncommon and has a documented neoplastic risk. We present the case of a 46-year-old woman with a large umbilical hernia associating primary umbilical endometriosis discovered during surgery and confirmed later by pathological and immunohistochemical exams. The patient underwent omphalectomy and partial omentum resection, alongside with mesh abdominal wall repair. The patient was informed about the recurrence risk and was asymptomatic at follow-up consults.

  9. Acute Abdomen Secondary to Incarcerated Umbilical Hernia after Treatment of Massive Cirrhotic Ascites

    PubMed Central

    Tan, Hiang Keat; Chang, Pik Eu

    2013-01-01

    Umbilical herniation is common in patients with liver cirrhosis and ascites. Rarely, they suffer from incarceration and strangulation of the umbilical hernia after treatment of ascites. We report 3 cases of umbilical hernia incarceration following removal of massive ascites with different treatment modalities. Physicians managing this group of patients should be aware of this rare and potentially fatal complication. PMID:25374722

  10. Effect of body position and ventilation on umbilical artery and venous blood flows during delayed umbilical cord clamping in preterm lambs.

    PubMed

    Hooper, Stuart B; Crossley, Kelly J; Zahra, Valerie A; van Vonderen, Jeroen; Moxham, Alison; Gill, Andrew W; Kluckow, Martin; Te Pas, Arjan B; Wallace, Euan M; Polglase, Graeme R

    2017-07-01

    While delayed umbilical cord clamping (UCC) is thought to facilitate placental to infant blood transfusion, the physiological factors regulating flow in the umbilical arteries and veins during delayed UCC is unknown. We investigated the effects of gravity, by changing fetal height relative to the placenta, and ventilation on umbilical blood flows and the cardiovascular transition during delayed UCC at birth. Catheters and flow probes were implanted into preterm lambs (128 days) prior to delivery to measure pulmonary, carotid, umbilical artery (UaBF) and umbilical venous (UvBF) blood flows. Lambs were placed either 10 cm below or 10 cm above the ewe. Ventilation commenced 2-3 min before UCC and continued for 30 min after UCC. Gravity reduced umbilical and cerebral flows when lambs were placed below the midline, but the reduction in UaBF and UvBF was similar. Ventilation during delayed UCC reduced UvBF and UaBF by similar amounts, irrespective of the lamb's position, such that flows into and out of the placenta remained balanced. The effects of ventilation on umbilical flows were much greater than the effects of gravity, but no net placental to lamb blood transfusion could be detected under any condition. Cardiovascular parameters, cerebral oxygen kinetics and final blood volumes were similar in both groups 5 min after UCC. Gravity caused small transient effects on umbilical and cerebral flow, but given changes were similar in umbilical arteries and veins, no net placental transfusion was detected. Ventilation during delayed UCC has a markedly greater influence on cardiovascular function in the newborn. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  11. Umbilical cord care in newborns

    MedlinePlus

    ... the stump clean with gauze and water only. Sponge bathe the rest of your baby, as well. ... Neonatal care - umbilical cord Images Umbilical cord healing Sponge bath References Carlo WA, Ambalavanan N. The umbilicus. ...

  12. Visualization of early post-implantation mouse embryogenesis using 3D imaging modality (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Hsu, Chih-Wei; Le, Henry H.; Li-Villarreal, Nanbing; Piazza, Victor G.; Kalaga, Sowmya; Dickinson, Mary E.

    2017-02-01

    Hemodynamic force is vital to cardiovascular remodeling in the early post-implantation mouse embryo. Here, we present work using microCT and lightsheet microscopy to establish the critical sequence of developmental events required for forming functional vasculature and circulation in the embryo, yolk sac, and placenta in the context of normal and impaired flow. A flow impaired model, Mlc2a+/- will be used to determine how hemodynamic force affects the specific events during embryonic development and vascular remodeling between the 4 and 29-somite stage using microCT. We have recently established high-resolution methods for the generation of 3D image volumes from the whole embryo within the deciduum (Hsu et al., in revision). This method enables the careful characterization of 3D images of vitelline and umbilical vessel remodeling to define how poor blood flow impacts both vitelline and umbilical vessel remodeling. Novel lightsheet live imaging techniques will be used to determine the consequence of impaired blood flow on yolk sac vasculature remodeling and formation of umbilical vessels using transgenic reporters: Flk-myr::mCherry, Flk1-H2B::YFP, or ɛGlobin-GFP. High-resolution 3D imaging of fixed and ScaleA2-cleared whole mount embryos labeled with Ki67 and Caspase3 will also be performed using lightsheet microscopy to quantify the proliferation and apoptotic indexes of early post-implanted embryos and yolk sac. This multi-modality approach is aimed at revealing further information about the cellular mechanisms required for proper vessel remodeling and the initial stages in placentation during early post-implantation development.

  13. Umbilical metastasis derived from early stage rectal cancer: a case report

    PubMed Central

    2014-01-01

    Background Umbilical metastasis, also called Sister Mary Joseph’s nodule (SMJN), is defined as the umbilical nodule associated with advanced metastatic intra-abdominal and pelvic malignancies. A patient with umbilical metastasis has been deemed to have a poor prognosis. Rectal cancer presenting with a SMJN is a rare phenomenon, especially in the early stage and in middle-low rectal cancer. Case presentation We report a case of a 70-year-old male presenting with umbilical metastasis derived from rectal cancer (10 cm from the anal verge, T2N0). Discussion and conclusion For rectal cancer with umbilical metastasis, the exact metastatic routes as well as the criterion of diagnosis and treatments are not very clear. Here we review the literature on rectal cancer and SMJN to deepen the understanding of this disease. PMID:24708697

  14. Effect of Hot Rolling Process on Microstructure and Properties of Low-Carbon Al-Killed Steels Produced Through TSCR Technology

    NASA Astrophysics Data System (ADS)

    Paul, S. K.; Ahmed, U.; Megahed, G. M.

    2011-10-01

    Low-carbon Al-killed hot rolled strips for direct forming, cold rolling, and galvanizing applications are produced from the similar chemistry at Ezz Flat Steel (EFS) through thin slab casting and rolling (TSCR) technology. The desired mechanical and microstructural properties in hot bands for different applications are achieved through control of hot rolling parameters, which in turn control the precipitation and growth of AlN. Nitrogen in solid solution strongly influences the yield strength (YS), ductility, strain aging index (SAI), and other formability properties of steel. The equilibrium solubility of AlN in austenite at different temperatures and its isothermal precipitation have been studied. To achieve the formability properties for direct forming, soluble nitrogen is fixed as AlN by coiling the strip at higher temperatures. For stringent cold forming, boron was added below the stoichiometric ratio with nitrogen, which improved the formability properties dramatically. The requirements of hot band for processing into cold rolled and annealed deep drawing sheets are high SAI and fine-grain microstructure. Higher finish rolling and low coiling temperatures are used to achieve these. Fully processed cold rolled sheets from these hot strips at customer's end have shown good formability properties. Coil break marks observed in some coils during uncoiling were found to be associated with yielding phenomenon. The spike height (difference between upper and lower yield stresses) and yield point elongation (YPE) were found to be the key material parameters for the break marks. Factors affecting these parameters have been studied and the coiling temperature optimized to overcome the problem.

  15. An ovary as unusual contents of an incarcerated umbilical hernia

    PubMed Central

    Ahmed, R; Kamat, S; Elkholy, K

    2014-01-01

    We present the unusual case of a woman presenting with an incarcerated umbilical hernia. Intraoperatively, the contents of the hernia were found to be an ovary. We outline the clinical presentation of our patient, investigations and management as well as a discussion on unusual contents of umbilical hernias. To our knowledge, this is the first case of a non-malignant ovary incarcerated in an umbilical hernia. PMID:25198958

  16. An ovary as unusual contents of an incarcerated umbilical hernia.

    PubMed

    Ahmed, U; Ahmed, R; Kamat, S; Elkholy, K

    2014-09-01

    We present the unusual case of a woman presenting with an incarcerated umbilical hernia. Intraoperatively, the contents of the hernia were found to be an ovary. We outline the clinical presentation of our patient, investigations and management as well as a discussion on unusual contents of umbilical hernias. To our knowledge, this is the first case of a non-malignant ovary incarcerated in an umbilical hernia.

  17. Microbial load of umbilical cord blood Ureaplasma species and Mycoplasma hominis in preterm prelabor rupture of membranes.

    PubMed

    Kacerovsky, Marian; Pliskova, Lenka; Menon, Ramkumar; Kutova, Radka; Musilova, Ivana; Maly, Jan; Andrys, Ctirad

    2014-11-01

    To evaluate Ureaplasma species and M. hominis DNA in the umbilical cord blood and its correlation with its microbial load in the amniotic fluid, as a measure of microbial burden in fetal inflammatory response and neonatal outcome in pregnancies complicated by preterm prelabor rupture of membranes (pPROM). A retrospective study of 158 women with singleton pregnancies complicated by pPROM between 24(0/7) and 36(6/7) weeks was conducted. Amniotic fluid was obtained from all women by transabdominal amniocentesis, and umbilical cord blood was obtained by venipuncture from umbilical cords immediately after the delivery of the neonates. The Ureaplasma species and M. hominis DNA was quantitated using absolute quantification techniques. Ureaplasma species and M. hominis DNA was identified in 9% of the umbilical cord blood samples. No correlation between the amniotic fluid and umbilical cord blood microbial load was observed. The presence of Ureaplasma species and M. hominis DNA in the umbilical cord blood had no impact on short-term neonatal morbidity. A high microbial load of genital mycoplasma Ureaplasma species DNA in the umbilical cord in pregnancies complicated by pPROM is not associated with a high fetal inflammatory response and is therefore not associated with serious neonatal morbidity.

  18. Giant Ovarian Tumor Presenting as an Incarcerated Umbilical Hernia: A Case Report

    PubMed Central

    Aydın, Özgür; Onur, Erdal; Çelik, Nilufer Yiğit; Moray, Gökhan

    2009-01-01

    We report a rare case of a giant ovarian tumor presenting as an incarcerated umbilical hernia. A 61-yr-old woman was admitted to the hospital with severe abdominal pain, an umbilical mass, nausea and vomiting. On examination, a large, irreducible umbilical hernia was found. The woman underwent an urgent operation for a possible strangulated hernia. A large, multilocular tumor was found. The tumor was excised, and a total abdominal hysterectomy and bilateral salphingo-oophorectomy were performed. The woman was discharged 6 days after her admission. This is the first report of incarcerated umbilical hernia containing a giant ovarian tumor within the sac. PMID:19543424

  19. Umbilical Hernia

    MedlinePlus

    ... Prompt diagnosis and treatment can help prevent complications. Causes During pregnancy, the umbilical cord passes through a small opening ... abdominal pressure can cause an umbilical hernia. Possible causes in adults include: ... pregnancies Fluid in the abdominal cavity (ascites) Previous abdominal ...

  20. ACOG committee opinion number 399, February 2008: umbilical cord blood banking.

    PubMed

    2008-02-01

    Two types of banks have emerged for the collection and storage of umbilical cord blood--public banks and private banks. Public banks promote allogenic (related or unrelated) donation, analogous to the current collection of whole blood units in the United States. Private banks were initially developed to store stem cells from umbilical cord blood for autologous use (taken from an individual for subsequent use by the same individual) by a child if the child develops disease later in life. If a patient requests information on umbilical cord blood banking, balanced and accurate information regarding the advantages and disadvantages of public versus private banking should be provided. The remote chance of an autologous unit of umbilical cord blood being used for a child or a family member (approximately 1 in 2,700 individuals) should be disclosed. The collection should not alter routine practice for the timing of umbilical cord clamping. Physicians or other professionals who recruit pregnant women and their families for for-profit umbilical cord blood banking should disclose any financial interests or other potential conflicts of interest.

  1. [Pathophysiological changes of umbilical vessels in intrauterine growth restriction].

    PubMed

    Jakó, Mária; Surányi, Andrea; Kaiser, László; Domokos, Dóra; Gáspár, Róbert; Bártfai, György

    2014-12-14

    The prevalence of intrauterine growth restriction is 4-5000/100,000 births, and they give the majority of perinatal morbidity. The aim of the authors was to compare the pathomorphologic data and vasoreactivity of umbilical vessels and placenta of small for date newborns to that of the normal pregnancies. Samples of the umbilical cord and placenta were divided into case and control groups. Two 10 cm long segments were cut of the umbilical cord at placental insertion. Tissue bath experiment was performed on umbilical vessels and pathomorphologic data were collected according to the Royal College of Pathologists' protocol. After the development of basal tone, oxytocin and desmopressin did not enhance the vascular contraction, but the pathomorphological and ultrasonographic data were significantly different in the two groups. The results indicate that umbilical vessels might not have oxytocin or vasopressin receptors. The pathomorphologic and flowmetric differences could be the causes of small birth weight.

  2. Gross umbilical cord complications are associated with placental lesions of circulatory stasis and fetal hypoxia.

    PubMed

    Chan, Joanna S Y; Baergen, Rebecca N

    2012-01-01

    Umbilical cord complications (UCC), such as true knots (TK), velamentous (VEL) insertion, marginal umbilical cord (MUC) insertion, umbilical cord entanglement (UCE) (both nuchal and non-nuchal), excessively long umbilical cord (ELUC), and excessively twisted umbilical cord (ETUC), can lead to decreased UC blood flow and have been associated with adverse fetal outcome and intrauterine fetal demise (IUFD). Few large series exist that correlate UCC with specific pathologic findings of the placenta. We present the largest series of UCC at this time. Eight hundred forty-one 3rd-trimester placentas with UCC were identified, as well as 858 randomly selected gestational age-matched placentas with grossly unremarkable UC. Lesions associated with circulatory stasis and thrombosis, including villous capillary congestion (VC), umbilical vessel distension (UVD), chorionic plate vessel distension (CPD), umbilical vessel thrombosis (UVT), fetal vascular thrombosis (FVT), intimal fibrin cushions (IFC), and avascular villi (AV), were noted, as well as other pathologic lesions. Data were analyzed by analysis of variance and Fisher exact tests, with P < 0.05 statistically significant. Umbilical cord complications as a group was associated with a significant increase in placental circulatory stasis lesions. Lesions associated with hypoxia, namely nucleated red blood cells and chorangiosis, were also increased. Finally, the presence of any UCC was significantly associated with IUFD. We also found that multiple UCC are associated with nonreassuring fetal heart rate and chorangiosis but that the presence of a single UCC was not. This indicates that UCC may lead to intrauterine hypoxia and subsequent adverse fetal outcome and that multiple UCC may be cumulative in effect.

  3. Low risk, but not no risk, of umbilical hernia complications requiring acute surgery in childhood.

    PubMed

    Ireland, Amanda; Gollow, Ian; Gera, Parshotam

    2014-04-01

    Umbilical hernias are a common finding in the paediatric community, with a preponderance to affect Afro-Caribbean and premature children. The rate of incarceration varies greatly between populations. Therefore, it is valuable to obtain some Australian data on this topic. We undertook a retrospective study of the records of all patients who underwent umbilical hernia repair over a 12-year period of between October 1999 and May 2012 at Princess Margaret Hospital. From this group, all patients that had an umbilical hernia repair for reason of acute complication were identified and analysed for age, ethnicity and co-morbidities. Between October 1999 and May 2012, 433 umbilical hernias were repaired at Princess Margaret Hospital, five of which were as the direct result of an acutely complicated umbilical hernia. The mean age of hernia repair was 5 years old, and the mean age of acute complication was 5 years old. Out of the patients with acutely complicated umbilical hernia, there were no Afro-Caribbean patients, and one was premature complicated by hyaline membrane disease and broncho-pulmonary dysplasia. Western Australia has an incidence of acutely complicated umbilical hernia requiring operative intervention of 1:3000 to 1:11,000. On an international scale, this is low, and studies with similar incidence do not advocate for immediate repair of all identified umbilical hernias. The authors believe repair should be guided by patient and guardian, but if there is an episode of incarceration, acute repair is advised. © 2013 The Authors. Journal of Paediatrics and Child Health © 2013 Paediatrics and Child Health Division (Royal Australasian College of Physicians).

  4. Core Stage Inter-Tank Umbilical (CSITU) Lift at ML

    NASA Image and Video Library

    2017-10-11

    A heavy-lift crane and rigging are used to lift the Core Stage Inter-tank Umbilical (CSITU) up to about the 140-foot level of the mobile launcher (ML) tower at NASA's Kennedy Space Center in Florida. The CSITU is moved into place for a fit check of the attachment hardware. The umbilical will then be lowered down and installed permanently on the ML at a later date. The CSITU is a swing-arm umbilical that will connect to the Space Launch System core stage inter-tank. It will provide conditioned air, pressurized gases and power and data connection to the core stage. The Ground Systems Development and Operations Program is overseeing installation of the umbilicals.

  5. MSCs with ACE II gene affect apoptosis pathway of acute lung injury induced by bleomycin.

    PubMed

    Zhang, Xiaomiao; Gao, Fengying; Li, Qian; Dong, Zhixia; Sun, Bo; Hou, Lili; Li, Zhuozhe; Liu, Zhenwei

    2015-02-01

    The aim of this study was to evaluate the effect and related mechanisms of Mesenchymal stem cells (MSCs) and Angiotensin converting enzyme II (ACE II) on acute lung injury (ALI). MSCs were separated from umbilical cord cells, and the changes of phenotype before and after ACE II silence were observed using Flow Cytometer. ALI model was induced by 10 mg/mL bleomycin in 60 Balb/c mice, and the rest 8 mice were regarded as the baseline group. The mice were randomly divided into four groups (n = 15): control, ACE II, stem, and stem + ACE II. The apoptotic index (AI) was calculated using TUNEL, and the detection of protein and mRNA of Bax, Bak and p53, Bcl-2, Grp78, CHOP and Caspase 12 were used by western-blot and RT-PCR, respectively. The umbilical cord cells differentiated into stable MSCs about 14 days, and ACE II transfection reached a peak at the 5th day after transfection. ACE II silence did not affect the phenotype of MSCs. All the proteins and mRNAs expression except Bcl-2 in the stem and stem + ACE II were significantly lower than those in control from 8 h (p < 0.05, p < 0.01), while Bcl-2 exhibited an opposite trend. Stem + ACE II performed a better effect than single stem in most indexes, including AI (p < 0.05, p < 0.01). The co-administration of MSCs and ACE II can significantly suppress apoptosis in ALI mice, and may be an effective clinical treatment for ALI.

  6. Mobile Launcher

    NASA Image and Video Library

    2017-05-30

    A view of the mobile launcher (ML) taken from the "eyebrow" of the nearby Vehicle Assembly Building at NASA's Kennedy Space Center in Florida. The ML tower will be equipped with a number of lines, called umbilicals that will connect to the Space Launch System rocket and Orion spacecraft for Exploration Mission-1 (EM-1). The Orion Service Module Umbilical and Core State Forward Skirt Umbilical were recently installed on the ML. The Ground Systems Development and Operations Program is overseeing installation of the umbilicals.

  7. Spontaneous evisceration of bowel through an umbilical hernia in a patient with refractory ascites

    PubMed Central

    Ogu, Uchechukwu Stanley; Valko, Janice; Wilhelm, Jakub; Dy, Victor

    2013-01-01

    Umbilical hernia in the cirrhotic patient is frequently seen in the setting of refractory ascites. This article reports a rare case of spontaneous rupture of a recurrent umbilical hernia in a patient with persistent ascites, following an acute increase in intra-abdominal pressure, leading to bowel evisceration. This case highlights a potentially fatal complication of umbilical hernia in the setting of chronic ascites, which was successfully managed with prompt surgical intervention. PMID:24964319

  8. Reference centiles for the middle cerebral artery and umbilical artery pulsatility index and cerebro-placental ratio from a low-risk population - a Generalised Additive Model for Location, Shape and Scale (GAMLSS) approach.

    PubMed

    Flatley, Christopher; Kumar, Sailesh; Greer, Ristan M

    2018-02-06

    The primary aim of this study was to create reference ranges for the fetal Middle Cerebral artery Pulsatility Index (MCA PI), Umbilical Artery Pulsatility Index (UA PI) and the Cerebro-Placental Ratio (CPR) in a clearly defined low-risk cohort using the Generalised Additive Model for Location, Shape and Scale (GAMLSS) method. Prospectively collected cross-sectional biometry and Doppler data from low-risk women attending the Mater Mother's Hospital, Maternal and Fetal Medicine Department in Brisbane, Australia between January 2010 and April 2017 were used to derive gestation specific centiles for the MCA PI, UA PI and CPR. All ultrasound scans were performed between 18 + 0 and 41 + 6 weeks gestation with recorded data for the MCA PI and/or UA PI. The GAMLSS method was used for the calculation of gestational age-adjusted centiles. Distributions and additive terms were assessed and the final model was chosen on the basis of the Global Deviance, Akaike information criterion (AIC) and Schwartz bayesian criterion (SBC), along with the results of the model and residual diagnostics as well as visual assessment of the centiles themselves. Over the study period 6013 women met the inclusion criteria. The MCA PI was recorded in 4473 fetuses, the UA PI in 6008 fetuses and the CPR was able to be calculated in 4464 cases. The centiles for the MCA PI used a fractional polynomial additive term and Box-Cox t (BCT) distribution. Centiles for the UA PI used a cubic spline additive term with BCT distribution and the CPR used a fractional polynomial additive term and a BCT distribution. We have created gestational centile reference ranges for the MCA PI, UA PI and CPR from a large low-risk cohort that supports their applicability and generalisability.

  9. 56. DETAIL OF PAYLOAD ELECTRICAL AND AIRCONDITIONING UMBILICAL CONNECTIONS ON ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    56. DETAIL OF PAYLOAD ELECTRICAL AND AIR-CONDITIONING UMBILICAL CONNECTIONS ON NORTH FACE OF SLC-3W UMBILICAL MAST - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 West, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  10. [Effect of Low Molecular Weight Heparin Calcium Combined Compound Danshen Injection on Perinatal Outcomes of Nephrotic Syndrome Patients with Early Onset Severe Pre-eclampsia].

    PubMed

    Tong, Chong-xin; Xing, Xiao-fen; Qiao, Shu-hua; Liu, Lin; Shan, Ling

    2015-08-01

    To observe the effect of low molecular weight heparin calcium (LMWHC) combined Compound Danshen Injection (DI) on nephrotic syndrome patients with early onset severe preeclampsia. Totally 80 nephrotic syndrome patients with early onset severe pre-eclampsia were randomly assigned to four groups voluntarily, i.e., Group A (22 cases, treated by magnesium sulfate), B (19 cases, treated by magnesium sulfate plus LMWHC), C (21 cases, magnesium sulfate plus DI), D (18 cases, magnesium sulfate plus LMWHC and DI). Umbilical arterial S/D ratios, amniotic fluid index (AFI), prolonged gestational age, placenta weight, neonatal weight, and Apgar score were compared among the four groups. Compared with before treatment in the same group, umbilical arterial S/D ratios decreased in the four groups (P <0. 05). AFI decreased in Group A, while it increased in Group B, C, and D (P<0. 05). Compared with Group A at the same time point, umbilical arterial S/D ratios decreased, and AFI increased in Group B, C, and D (P <0. 01 , P <0. 05). Prolonged gestational age and neonatal weight were increased in Group B, C, and D (P <0. 01, P <0. 05). Placenta weight were increased in Group B and D (P <0. 05). Apgar scores at 1 and 5 min were improved in Group D (P <0. 05). Compared with Group B and C at the same time point, umbilical arterial S/D ratios decreased, and AFI increased in Group D (P<0. 05). Compared with Group B, prolonged gestational age and placenta weight were decreased in Group C, but prolonged gestational age and placenta weight were increased in Group D (P <0.05). Compared with Group C, prolonged gestational age, placenta weight, and neonatal weight were increased in Group D (P <0. 05). Treatment of nephrotic syndrome patients with early onset severe pre-eclampsia by LMWHC combined DI could prolong gestational ages, obviously improve prenatal outcomes, with better effect obtained than using any of them alone.

  11. Ethical issues relating the the banking of umbilical cord blood in Mexico.

    PubMed

    Serrano-Delgado, V Moises; Novello-Garza, Barbara; Valdez-Martinez, Edith

    2009-08-14

    Umbilical cord banks are a central component, as umbilical cord tissue providers, in both medical treatment and scientific research with stem cells. But, whereas the creation of umbilical cord banks is seen as successful practice, it is perceived as a risky style of play by others. This article examines and discusses the ethical, medical and legal considerations that arise from the operation of umbilical cord banks in Mexico. A number of experts have stated that the use of umbilical cord goes beyond the mere utilization of human tissues for the purpose of treatment. This tissue is also used in research studies: genetic studies, studies to evaluate the effectiveness of new antibiotics, studies to identify new proteins, etc. Meanwhile, others claim that the law and other norms for the functioning of cord banks are not consistent and are poorly defined. Some of these critics point out that the confidentiality of donor information is handled differently in different places. The fact that private cord banks offer their services as "biological insurance" in order to obtain informed consent by promising the parents that the tissue that will be stored insures the health of their child in the future raises the issue of whether the consent is freely given or given under coercion. Another consideration that must be made in relation to privately owned cord banks has to do with the ownership of the stored umbilical cord. Conflicts between moral principles and economic interests (non-moral principles) cause dilemmas in the clinical practice of umbilical cord blood storage and use especially in privately owned banks. This article presents a reflection and some of the guidelines that must be followed by umbilical cord banks in order to deal with these conflicts. This reflection is based on the fundamental notions of ethics and public health and seeks to be a contribution towards the improvement of umbilical cord banks' performance.

  12. Ethical issues relating to the banking of umbilical cord blood in Mexico

    PubMed Central

    2009-01-01

    Background Umbilical cord banks are a central component, as umbilical cord tissue providers, in both medical treatment and scientific research with stem cells. But, whereas the creation of umbilical cord banks is seen as successful practice, it is perceived as a risky style of play by others. This article examines and discusses the ethical, medical and legal considerations that arise from the operation of umbilical cord banks in Mexico. Discussion A number of experts have stated that the use of umbilical cord goes beyond the mere utilization of human tissues for the purpose of treatment. This tissue is also used in research studies: genetic studies, studies to evaluate the effectiveness of new antibiotics, studies to identify new proteins, etc. Meanwhile, others claim that the law and other norms for the functioning of cord banks are not consistent and are poorly defined. Some of these critics point out that the confidentiality of donor information is handled differently in different places. The fact that private cord banks offer their services as "biological insurance" in order to obtain informed consent by promising the parents that the tissue that will be stored insures the health of their child in the future raises the issue of whether the consent is freely given or given under coercion. Another consideration that must be made in relation to privately owned cord banks has to do with the ownership of the stored umbilical cord. Summary Conflicts between moral principles and economic interests (non-moral principles) cause dilemmas in the clinical practice of umbilical cord blood storage and use especially in privately owned banks. This article presents a reflection and some of the guidelines that must be followed by umbilical cord banks in order to deal with these conflicts. This reflection is based on the fundamental notions of ethics and public health and seeks to be a contribution towards the improvement of umbilical cord banks' performance. PMID:19678958

  13. Structure and non-structure of centrosomal proteins.

    PubMed

    Dos Santos, Helena G; Abia, David; Janowski, Robert; Mortuza, Gulnahar; Bertero, Michela G; Boutin, Maïlys; Guarín, Nayibe; Méndez-Giraldez, Raúl; Nuñez, Alfonso; Pedrero, Juan G; Redondo, Pilar; Sanz, María; Speroni, Silvia; Teichert, Florian; Bruix, Marta; Carazo, José M; Gonzalez, Cayetano; Reina, José; Valpuesta, José M; Vernos, Isabelle; Zabala, Juan C; Montoya, Guillermo; Coll, Miquel; Bastolla, Ugo; Serrano, Luis

    2013-01-01

    Here we perform a large-scale study of the structural properties and the expression of proteins that constitute the human Centrosome. Centrosomal proteins tend to be larger than generic human proteins (control set), since their genes contain in average more exons (20.3 versus 14.6). They are rich in predicted disordered regions, which cover 57% of their length, compared to 39% in the general human proteome. They also contain several regions that are dually predicted to be disordered and coiled-coil at the same time: 55 proteins (15%) contain disordered and coiled-coil fragments that cover more than 20% of their length. Helices prevail over strands in regions homologous to known structures (47% predicted helical residues against 17% predicted as strands), and even more in the whole centrosomal proteome (52% against 7%), while for control human proteins 34.5% of the residues are predicted as helical and 12.8% are predicted as strands. This difference is mainly due to residues predicted as disordered and helical (30% in centrosomal and 9.4% in control proteins), which may correspond to alpha-helix forming molecular recognition features (α-MoRFs). We performed expression assays for 120 full-length centrosomal proteins and 72 domain constructs that we have predicted to be globular. These full-length proteins are often insoluble: Only 39 out of 120 expressed proteins (32%) and 19 out of 72 domains (26%) were soluble. We built or retrieved structural models for 277 out of 361 human proteins whose centrosomal localization has been experimentally verified. We could not find any suitable structural template with more than 20% sequence identity for 84 centrosomal proteins (23%), for which around 74% of the residues are predicted to be disordered or coiled-coils. The three-dimensional models that we built are available at http://ub.cbm.uam.es/centrosome/models/index.php.

  14. Placental passage of antiepileptic drugs at delivery and neonatal outcomes

    PubMed Central

    Bank, Anna M.; Stowe, Zachary N.; Newport, D. Jeffrey; Ritchie, James C.; Pennell, Page B.

    2017-01-01

    Summary Children of women treated with antiepileptic drugs (AEDs) are at increased risk for adverse outcomes detectable in the neonatal period, which may be associated with the amount of AED in the fetal circulation. Placental passage of AEDs can be measured by calculating the ratio of umbilical cord to maternal AED concentrations collected at delivery. The aims of this study were to determine the umbilical cord concentrations and umbilical to maternal ratios for AEDs, and to determine whether higher cord concentrations are associated with increased risk of neonatal complications. AED cord and maternal blood concentrations from 70 mother-newborn dyads and neonatal complications were recorded. Logistic regressions were performed to determine the association between AED concentrations and complications. Mean umbilical to maternal ratios for total concentrations ranged from 0.79 for carbamazepine to 1.20 for valproic acid, and mean umbilical to maternal ratios for free concentrations ranged from 0.86 for valproic acid to 1.42 for carbamazepine, indicating complete placental passage. Neither umbilical cord concentrations nor umbilical to maternal ratios were associated with adverse neonatal outcomes. Additional investigations are warranted to delineate the relationship between quantified fetal AED exposure and neonatal complications. PMID:28387929

  15. Robotic-assisted laparoscopic prostatectomy in umbilical hernia patients: University of California, Irvine, technique for port placement and repair.

    PubMed

    Kim, William; Abdelshehid, Corollos; Lee, Hak J; Ahlering, Thomas

    2012-06-01

    To discuss a technique currently used at our institution for the management of umbilical hernias during robot-assisted laparoscopic prostatectomy. As more patients undergo robot-assisted radical prostatectomy, there will be an increase in patients who qualify for robotic surgery with comorbidities. This technique has been utilized in clinically localized prostate cancer patients with umbilical hernias using the da Vinci Surgical System and standard laparoscopic instrumentation. Port placements and closures were performed by a resident assistant and a nurse at the operating table. The prostatectomy was performed by a single experienced surgeon at the console. Currently, no data are available regarding patients with umbilical hernias undergoing robotic prostatectomy. We reviewed our technique of port placement for patients with a pre-existing umbilical hernia undergoing robot-assisted laparoscopic prostatectomy. This technique allows for a reduction of the umbilical hernia, the use of the fascial defect as a robotic port, and the removal of the prostate by way of transverse incision and transverse repair. In our experience, this technique is feasible and reproducible for any small or large umbilical hernia. Copyright © 2012 Elsevier Inc. All rights reserved.

  16. Patent omphalomesenteric duct of the vermiform appendix in a neonate: congenital appendicoumbilical fistula.

    PubMed

    Crankson, S J; Ahmed, G S; Palkar, V

    1998-12-01

    Umbilical anomalies arise from fetal structures such as the omphalomesenteric duct (OMD) or urachus or from failure of closure of the umbilical fascial ring. Persistence of the OMD may lead to several anomalies including umbilical sinus, umbilical cyst, Meckel's diverticulum, or patent OMD (POMD). A POMD is usually associated with the ileum, but rarely may be with the caecum or appendix. We describe a POMD of the vermiform appendix and discuss the possible pathogenesis and management.

  17. Hepatic laceration as a life-threatening complication of umbilical venous catheterization.

    PubMed

    Gülcan, Hande; Hanta, Deniz; Törer, Birgin; Temiz, Adbülkerim; Demir, Senay

    2011-01-01

    Umbilical venous catheterization is an intravenous infusion route for maintenance fluids, medications, blood products, and parenteral nutrition in preterm neonates. However, this procedure may be associated with several complications, such as infection, thrombosis, vessel perforation, and cardiac and hepatic injuries. Hepatic laceration is a rare but life-threatening complication of umbilical venous catheterization that is a result of direct injury through the liver parenchyma. Here, we present a preterm newborn with hepatic laceration as a rare and serious complication of umbilical venous catheterization.

  18. Rupture of Umbilical Hernia with Evisceration in a Newborn - A Case Report.

    PubMed

    Kittur, Dinesh H; Bhandarkar, Kailas P; Patil, Santosh V; Jadhav, Sudhakar S

    2017-01-01

    Most umbilical hernias in infants do not need surgery and the ring will eventually close. Occasionally few complications can arise and incarceration is most common. Spontaneous rupture of the hernia and eventual evisceration is a rarely seen complication. A 3-week-old neonate having umbilical hernia presented with rupture of the sac with evisceration of bowel within a few days of first visit. No underlying cause like umbilical sepsis was found. The baby had emergency repair of the hernia with an uneventful recovery.

  19. Incarceration of umbilical hernia after radiological insertion of a Denver peritoneovenous shunt.

    PubMed

    Ohta, Kengo; Shimohira, Masashi; Hashizume, Takuya; Kawai, Tatsuya; Kurosaka, Kenichiro; Suzuki, Kazushi; Watanabe, Kenichi; Shibamoto, Yuta

    2013-03-01

    We report a rare complication of incarceration of an umbilical hernia after Denver peritoneovenous shunt placement. A 50-year-old man presented with refractory ascites from liver cirrhosis. He also had an umbilical hernia. Because the ascites became uncontrollable, Denver peritoneovenous shunting was performed. The operation was successful and the ascites decreased. Ten days later, however, incarceration of the umbilical hernia occurred. A surgical repair was performed, but he died 2 days later. The cause of death was considered to be sepsis.

  20. Comparative studies of mesenchymal stem cells derived from different cord tissue compartments - The influence of cryopreservation and growth media.

    PubMed

    Dulugiac, Magda; Moldovan, Lucia; Zarnescu, Otilia

    2015-10-01

    We have identified some critical aspects concerning umbilical cord tissue mesenchymal stem cells: the lack of standards for cell isolation, expansion and cryopreservation, the lack of unanimous opinions upon their multilineage differentiation potential and the existence of very few results related to the functional characterization of the cells isolated from cryopreserved umbilical cord tissue. Umbilical cord tissue cryopreservation appears to be the optimal solution for umbilical cord tissue mesenchymal stem cells storage for future clinical use. Umbilical cord tissue cryopreservation allows mesenchymal stem cells isolation before expected use, according with the specific clinical applications, by different customized isolation and expansion protocols agreed by cell therapy institutions. Using an optimized protocol for umbilical cord tissue cryopreservation in autologous cord blood plasma, isolation explant method and growth media supplemented with FBS or human serum, we performed comparative studies with respect to the characteristics of mesenchymal stem cells (MSC) isolated from different compartments of the same umbilical cord tissue such as Wharton's jelly, vein, arteries, before cryopreservation (pre freeze) and after cryopreservation (post thaw). Expression of histochemical and immunohistochemical markers as well as electron microscopy observations revealed similar adipogenic, chondrogenic and osteogenic differentiation capacity for cells isolated from pre freeze and corresponding post thaw tissue fragments of Wharton's jelly, vein or arteries of the same umbilical cord tissue, regardless growth media used for cells isolation and expansion. Our efficient umbilical cord tissue cryopreservation protocol is reliable for clinical applicability of mesenchymal stem cells that could next be isolated and expanded in compliance with future accepted standards. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Umbilical cord blood: a guide for primary care physicians.

    PubMed

    Martin, Paul L; Kurtzberg, Joanne; Hesse, Brett

    2011-09-15

    Umbilical cord blood stem cell transplants are used to treat a variety of oncologic, genetic, hematologic, and immunodeficiency disorders. Physicians have an important role in educating, counseling, and offering umbilical cord blood donation and storage options to patients. Parents may donate their infant's cord blood to a public bank, pay to store it in a private bank, or have it discarded. The federal government and many state governments have passed laws and issued regulations regarding umbilical cord blood, and some states require physicians to discuss cord blood options with pregnant women. Five prominent medical organizations have published recommendations about cord blood donation and storage. Current guidelines recommend donation of umbilical cord blood to public banks when possible, or storage through the Related Donor Cord Blood Program when a sibling has a disease that may require a stem cell transplant. Experts do not currently recommend private banking for unidentified possible future use. Step-by-step guidance and electronic resources are available to physicians whose patients are considering saving or donating their infant's umbilical cord blood.

  2. [Umbilical Hernia Complicated by Gastrointestinal Stromal Tumor of the Small Intestine - A Case Report].

    PubMed

    Tsukada, Manabu; Ozaki, Akihiko; Ohira, Hiromichi; Sawano, Toyoaki; Nemoto, Tsuyoshi; Kanazawa, Yukio

    2016-11-01

    Intraabdominal tumors can cause umbilical hernia and may lead to serious consequences, such as incarcerated or necrotized intestine. However, little information is available concerning how the location and characteristics of tumors may affect the process of umbilical hernia development. A 46-year-old Japanese man presented at the department of surgery with abdominal pain and abdominal retention, which appeared on the day of presentation and 4 years before the presentation, respectively. Abdominal computed tomography revealed a suspected gastrointestinal stromal tumor(GIST)and an umbilical hernia close to the tumor, both of which were clinically diagnosed. Surgical tumor resection and hernia repair were conducted successfully. The patient was pathologically diagnosed with high-risk GIST. Adjuvant therapy with imatinib was administered with no recurrence as of 1 year post-surgery. This is a case of GIST complicated by umbilical hernia. Small solid tumors may cause umbilical hernia if they are in close proximity to vulnerable parts of the abdominal wall.

  3. Umbilical Hernia in Peritoneal Dialysis Patients: Surgical Treatment and Risk Factors.

    PubMed

    Banshodani, Masataka; Kawanishi, Hideki; Moriishi, Misaki; Shintaku, Sadanori; Ago, Rika; Hashimoto, Shinji; Nishihara, Masahiro; Tsuchiya, Shinichiro

    2015-12-01

    No previous reports have focused on surgical treatments and risk factors of umbilical hernia alone in peritoneal dialysis (PD) patients. Herein, we evaluated the treatments and risk factors. A total of 411 PD patients were enrolled. Of the 15 patients with umbilical hernia (3.6%), six underwent hernioplasty. There was no recurrence in five patients treated with tension-free hernioplasty. The mean PD vintage after onset of hernia in the hernioplasty group tended to be longer than that in the non-hernioplasty group. An incarcerated hernia occurred in one non-hernioplasty patient. Although the incidence was significantly higher among women (P = 0.02), female sex was not a risk factor for umbilical hernia (P = 0.08). Our findings suggest that umbilical hernias should be repaired for continuing PD. Furthermore, there were no significant risk factors for umbilical hernia in PD patients. Future studies with larger sample groups are required to elucidate these risk factors. © 2015 International Society for Apheresis, Japanese Society for Apheresis, and Japanese Society for Dialysis Therapy.

  4. Traumatic diaphragmatic rupture through the central tendon with herniation of the stomach and coils of small bowel into the pericardial cavity.

    PubMed

    Nwafor, I A; Eze, J C; Aminu, M B

    2011-01-01

    Traumatic diaphragmatic rupture through the central tendon with herniation of the stomach and coils of small bowel into the pericardial cavity. Case note of a patient managed for traumatic diaphragmatic rupture through the central tendon with herniation of the stomach and coils of small bowel into the pericardial cavity was used with a review of relevant literature. A 49-year old civil engineer who presented with 2-year history of easy fatigability and palpitations as well as a 6-month history of hypertension and was initially managed as a case dilated cardiomyopathy to rule out incipient CCF secondary to hypertension, was evaluated and found to have chronic diaphragmatic hernia through the central tendon with evisceration of the stomach and coils of the small bowel into the pericardial cavity. Though there was history of motor vehicle crash preceding the development of the symptoms, but the long history of effort dyspnoea and palpitations added to enlarged cardiac silhouette on posterior anterior chest x-ray, a diagnostic challenge was posed which was resolved by thoracoabdominal CT scan. Patient had left sided posteriorlateral thoracotomy via 7h intercostal space followed with reduction of thq stomach and coils of small bowel after careful adhesiolysis and repair of the defect in double layers. High index of suspicion is very important in the diagnosis of diaphragmatic central tendon injury considering the rarity of the injury and diagnostic challenges it poses in chronic form. However, where the facilities are available, CT scan and 2-D echo will most of the time clinch the diagnosis; also is upper gastrointestinal series.

  5. Anatomical description of the umbilical arteries and impact of their ligation on pelvic and perineal vascular supply after cystectomy in women.

    PubMed

    Chantalat, E; Vaysse, C; Delchier, M C; Bordier, B; Game, X; Chaynes, P; Cavaignac, E; Roumiguié, M

    2018-03-27

    In radical cystectomy, the surgeon generally ligates the umbilical artery at its origin. This artery may give rise to several arteries that supply the sexual organs. Our aim was to evaluate pelvic and perineal devascularisation in women after total cystectomy. We carried out a prospective anatomical and radiological study. We performed bilateral pelvic dissections of fresh adult female cadavers to identify the dividing branches of the umbilical artery. In parallel, we examined and compared the pre- and postoperative imaging investigations [magnetic resonance imaging (MRI) angiography] in patients undergoing cystectomy for benign disease to quantify the loss of pelvic vascularisation on the postoperative images by identifying the occluded arteries. The anatomical study together with the radiological study visualised 35 umbilical arteries (n = 70) with their branching patterns and collateral arteries. The uterine artery originated from the umbilical artery in more than 75% of cases (n = 54) of the internal pudendal artery in 34% (n = 24) and the vaginal artery in 43% (n = 30). The postoperative MRI angiograms showed pelvic devascularisation in four patients. Devascularisation was dependent on the level of surgical ligation. In the four patients with loss of pelvic vascular supply, the umbilical artery had been ligated at its origin. The umbilical artery gives rise to various branches that supply the pelvis and perineum. If the surgeon ligates the umbilical artery at its origin during total cystectomy, there is a significant risk of pelvic and perineal devascularisation.

  6. Treatment of umbilical hernia and recti muscles diastasis without a periumbilical incision.

    PubMed

    Kulhanek, J; Mestak, O

    2013-08-01

    Postpartum rectus diastasis eventually combined with umbilical hernia is a condition that is frequently treated by plastic surgeons and general surgeons. Standard treatment of this condition is abdominoplasty with a periumbilical incision, which often results in an umbilical incision or an inverted-T scar. Limited incision abdominoplasty differs from traditional abdominoplasty by disconnecting the umbilical stalk from the abdominal wall during flap dissection, thus allowing the resection of excess skin above and under the umbilicus without causing periumbilical scarring. We conducted a retrospective cohort study of women undergoing a limited scar abdominoplasty without a periumbilical incision for the treatment of a separation of the recti muscles and/or an umbilical hernia. We recorded the postoperative complications and patient satisfaction with the results of the treatment. We operated on 50 patients from 2002 to 2010. We followed the patients for 2-8 years. The most common complication, as with other abdominoplasty procedures, was minor dehiscention in the middle part of the wound, which occurred in 16 % (n = 8) of the patients. All of these complications were treated conservatively. No recurrence of diastasis or umbilical hernia was observed. Extended miniabdominoplasty with a low suprapubic incision and umbilical caudalization for treating the diastasis of the abdominal rectus muscles and/or an umbilical hernia is an excellent method that results in a small, hidden scar. This method is especially beneficial for young, slim women with an abdominal wall deformity after pregnancy.

  7. Determinants of brain-derived neurotrophic factor (BDNF) in umbilical cord and maternal serum.

    PubMed

    Flöck, A; Weber, S K; Ferrari, N; Fietz, C; Graf, C; Fimmers, R; Gembruch, U; Merz, W M

    2016-01-01

    Brain-derived neurotrophic factor (BDNF) plays a fundamental role in brain development; additionally, it is involved in various aspects of cerebral function, including neurodegenerative and psychiatric diseases. Involvement of BDNF in parturition has not been investigated. The aim of our study was to analyze determinants of umbilical cord BDNF (UC-BDNF) concentrations of healthy, term newborns and their respective mothers. This cross-sectional prospective study was performed at a tertiary referral center. Maternal venous blood samples were taken on admission to labor ward; newborn venous blood samples were drawn from the umbilical cord (UC), before delivery of the placenta. Analysis was performed with a commercially available immunoassay. Univariate analyses and stepwise multivariate regression models were applied. 120 patients were recruited. UC-BDNF levels were lower than maternal serum concentrations (median 641 ng/mL, IQR 506 vs. median 780 ng/mL, IQR 602). Correlation between UC- and maternal BDNF was low (R=0.251, p=0.01). In univariate analysis, mode of delivery (MoD), gestational age (GA), body mass index at delivery, and gestational diabetes were determinants of UC-BDNF (MoD and smoking for maternal BDNF, respectively). Stepwise multivariate regression analysis revealed a model with MoD and GA as determinants for UC-BDNF (MoD for maternal BDNF). MoD and GA at delivery are determinants of circulating BDNF in the mother and newborn. We hypothesize that BDNF, like other neuroendocrine factors, is involved in the neuroendocrine cascade of delivery. Timing and mode of delivery may exert BDNF-induced effects on the cerebral function of newborns and their mothers. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Effects of preoperative carprofen on cardio-respiratory, hormonal and metabolic stress response in calves during umbilical surgery under isoflurane inhalation anaesthesia.

    PubMed

    Schulze, I; Poos, E M; Meyer, H; List, A K; Kaestner, S B R; Rehage, J

    2016-10-01

    The aim of this study was to examine the effects of preoperative carprofen on the cardiorespiratory, hormonal and metabolic stress response during umbilical surgery under isoflurane anaesthesia combined with local anaesthesia, in calves. A randomised, blinded experimental study was conducted in 24 calves. Carprofen (n = 12; 1.4 mg/kg) or physiological saline solution (controls; n = 12) was administered 1 h prior to surgery. Anaesthesia was induced with xylazine (0.1 mg/kg, IM) and, after the onset of sedation (i.e. after 5-8 min), ketamine was administered (2 mg/kg, IV). Anaesthesia was then maintained with isoflurane (ISO) in oxygen to effect and completed by infiltration of the incision line with 20 mL of 2% procaine. Cardiorespiratory, endocrine and metabolic parameters were examined before, during and after surgery at short intervals. In both groups, anaesthesia appeared adequate for the surgical intervention. Heart rate, stroke index and arterial blood pressure were significantly elevated after the onset of surgery. Oxygen partial pressure and oxygen delivery increased, while the oxygen extraction ratio decreased intraoperatively, ensuring sufficient oxygen supply. In the control group, the mean surge in serum cortisol concentrations tended to be higher (P = 0.089) and systemic vascular resistance (SVR) was significantly greater (P <0.05) than in the carprofen group during surgery. In conclusion, the anaesthetic protocol used in this study induced reliable analgesia in both groups. The lower serum cortisol levels and SVR may indicate a reduced surgical stress response in calves undergoing umbilical surgery under ISO anaesthesia after administering carprofen preoperatively. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. The relationship between human placental morphometry and ultrasonic measurements of utero-placental blood flow and fetal growth.

    PubMed

    Salavati, N; Sovio, U; Mayo, R Plitman; Charnock-Jones, D S; Smith, G C S

    2016-02-01

    Ultrasonic fetal biometry and arterial Doppler flow velocimetry are widely used to assess the risk of pregnancy complications. There is an extensive literature on the relationship between pregnancy outcomes and the size and shape of the placenta. However, ultrasonic fetal biometry and arterial Doppler flow velocimetry have not previously been studied in relation to postnatal placental morphometry in detail. We conducted a prospective cohort study of nulliparous women in The Rosie Hospital, Cambridge (UK). We studied a group of 2120 women who had complete data on uterine and umbilical Doppler velocimetry and fetal biometry at 20, 28 and 36 weeks' gestational age, digital images of the placenta available, and delivered a liveborn infant at term. Associations were expressed as the difference in the standard deviation (SD) score of the gestational age adjusted ultrasound measurement (z-score) comparing the lowest and highest decile of the given placental morphometric measurement. The lowest decile of placental surface area was associated with 0.87 SD higher uterine artery Doppler mean pulsatility index (PI) at 20 weeks (95% CI: 0.68 to 1.07, P < 0.001). The lowest decile of placental weight was associated with 0.73 SD higher umbilical artery Doppler PI at 36 weeks (95% CI: 0.54 to 0.93, P < 0.001). The lowest decile of both placental weight and placental area were associated with reduced growth velocity of the fetal abdominal circumference between 20 and 36 weeks (both P < 0.001). Placental area and weight are associated with uterine and umbilical blood flow, respectively, and both are associated with fetal growth rate. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. 126. REDUNDANCY SYSTEM CONTROLS FOR UMBILICAL MAST RETRACTION AT LOWER ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    126. REDUNDANCY SYSTEM CONTROLS FOR UMBILICAL MAST RETRACTION AT LOWER LEFT SIDE OF HYDRAULIC CONTROL PANEL IN UMBILICAL MAST PUMP ROOM (209), LSB (BLDG. 751) - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 East, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  11. 109. REDUNDANCY SYSTEM CONTROLS FOR UMBILICAL MAST RETRACTION AT LOWER ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    109. REDUNDANCY SYSTEM CONTROLS FOR UMBILICAL MAST RETRACTION AT LOWER LEFT SIDE OF HYDRAULIC CONTROL PANEL IN UMBILICAL MAST PUMP ROOM (109), LSB (BLDG. 770) - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 West, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  12. 127. HYDRAULIC CONTROLS AND GAUGES FOR THE UMBILICAL MAST ON ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    127. HYDRAULIC CONTROLS AND GAUGES FOR THE UMBILICAL MAST ON UPPER RIGHT SIDE OF HYDRAULIC CONTROL PANEL IN UMBILICAL MAST PUMP ROOM (209), LSB (BLDG. 751) - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 East, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  13. 123. UMBILICAL MAST PUMP ROOM (209), LSB (BLDG. 751). PUMP ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    123. UMBILICAL MAST PUMP ROOM (209), LSB (BLDG. 751). PUMP ON LEFT; HYDRAULIC CONTROL PANEL FOR UMBILICAL MAST AND TRENCH DOORS IN CENTER OF ROOM, FACING WEST. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 East, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  14. The conception, birth, and growth of a missile umbilical system

    NASA Technical Reports Server (NTRS)

    Nordman, G. W.

    1977-01-01

    The design development of the Sprint 2 and the Improved Sprint 2 Missile System umbilical system is reviewed. Unique system requirements, umbilical designs considered to meet the requirements, and the problems encountered and solutions derived during the design and development testing of the selected systems are described.

  15. 42. VIEW OF UMBILICAL MAST AND LAUNCH PAD FROM MST ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    42. VIEW OF UMBILICAL MAST AND LAUNCH PAD FROM MST BASE. LAUNCHER IS BEHIND UMBILICAL MAST AND RAIL SYSTEM IS PARALLEL TO MAST ON RIGHT AND LEFT. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 East, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  16. Obstructed Umbilical Hernia: A Normal Presentation with Abnormal Contents.

    PubMed

    P Agrawal, Vijay; S Shetty, Nikhil; Narasimhaprasad, Ashwin

    2015-01-01

    Umbilical hernia is a common problem encountered in children. The rarity of finding cecum and appendix is probably due to the fact that the appendix is seldom found in the proximity of the umbilicus. It would, therefore, appear worthwhile to report the occurrence of cecum and an inflamed appendix with Ladd's bands in an umbilical hernia of a child. The last case with similar presentation was presented in 1950s. Agrawal VP, Shetty NS, Narasimhaprasad A. Obstructed Umbilical Hernia: A Normal Presentation with Abnormal Contents. Euroasian J Hepato-Gastroenterol 2015;5(2):110-111.

  17. Concentrations of amino acids in plasma from 45- to 47-week gestation mares and foetuses (Equus caballus).

    PubMed

    Zicker, S C; Vivrette, S; Rogers, Q R

    1994-06-01

    Concentrations of 16 of 24 amino acids in plasma of foetuses were significantly higher, while four of 24 were lower, than their concentration in maternal plasma. The higher foetal concentrations of amino acids in plasma are similar to other species, with some exceptions, and suggest that equine placenta actively transports and concentrates amino acids into the umbilical circulation. Concentrations of nine of 24 amino acids were significantly lower in plasma from the umbilical artery compared to plasma from the umbilical vein, while no significant differences were present between maternal artery and vein plasma. The umbilical venous-arterial difference in concentrations of amino acids in plasma suggests the foetus extracts amino acids from the umbilical circulation for catabolism or protein synthesis, as in other species.

  18. The crying sign: the winking umbilical cord

    PubMed Central

    Smith, Aisling M; Healy, David B; Ryan, C Anthony; Dempsey, Eugene M

    2015-01-01

    A preterm baby girl, born at 34 weeks gestation, with features of Beckwith-Wiedemann syndrome was noted to have a relatively large umbilical stump. No fetal abnormalities had been detected on anatomy scan at 28 weeks and only mild polyhydramnios and macrosomia were noted on a 32-week ultrasound scan. Although there was no obvious omphalocoele, clinical assessment of the umbilical cord revealed an abdominal wall defect through which bowel would protrude into the umbilicus when the infant was crying. In keeping with an abdominal wall defect α-fetoprotein was found to be elevated. Surgical consultation advised conservative management. Subsequently, detachment of the umbilical cord occurred 1 week postdischarge and a large umbilical hernia persists. Genetic analysis confirmed a diagnosis of Beckwith-Wiedemann syndrome. PMID:25820111

  19. A "Kane's Dynamics" Model for the Active Rack Isolation System. Part 3; Addition of Umbilicals to the Nonlinear Model

    NASA Technical Reports Server (NTRS)

    Rupert, J. K.; Hampton, R. D.; Beech, G. S.

    2005-01-01

    In the late 1980s, microgravity researchers began to voice their concern that umbilical-transmitted energy could significantly degrade the acceleration environment of microgravity space science experiments onboard manned spacecraft. Since umbilicals are necessary for many experiments, control designers began to seek ways to compensate for these "indirect" disturbances. Hampton, et al., used the Kane s method to develop a model of the active rack isolation system (ARIS) that includes (1) actuator control forces, (2) direct disturbance forces, and (3) indirect, actuator-transmitted disturbances. Their model does not, however, include the indirect, umbilical-transmitted disturbances. Since the umbilical stiffnesses are not negligible, these indirect disturbances must be included in the model. Until the umbilicals have been appropriately included, the model will be incomplete. This Technical Memorandum presents a nonlinear model of ARIS with umbilicals included. Model verification was achieved by utilizing two commercial-off-the-shelf software tools. Various forces and moments were applied to the model to yield simulated responses of the system. Plots of the simulation results show how various critical points on an ARIS-outfitted international standard payload rack behave under the application of direct disturbances, indirect disturbances, and control forces. Simulations also show system response to a variety of initial conditions.

  20. Umbilical hernia: Influence of adhesive strapping on outcome.

    PubMed

    Hayashida, Makoto; Shimozono, Takashi; Meiri, Satoru; Kurogi, Jun; Yamashita, Naoto; Ifuku, Toshinobu; Yamamura, Yoshiko; Tanaka, Etsuko; Ishii, Shigeki; Shimonodan, Hidemi; Mihara, Yuka; Kono, Keiichiro; Nakatani, Keigo; Nishiguchi, Toshihiro

    2017-12-01

    Adhesive strapping for umbilical hernia has been re-evaluated as a promising treatment. We evaluated the influence of adhesive strapping on the outcome of umbilical hernia. We retrospectively evaluated patients with umbilical hernia referred to the present institution from April 2011 to December 2015. Patients who were treated with adhesive strapping were compared with an observation alone group. The adhesive strapping group was also subdivided into two groups: the cure group and the treatment failure group. A total of 212 patients with umbilical hernia were referred to the present institution. Eighty-nine patients were treated with adhesive strapping, while 27 had observation only. The cure rate in the adhesive strapping group was significantly higher than that in the observation group. The duration of treatment of the adhesive strapping group was significantly shorter than that of the observation group. In the adhesive strapping group, the patients in the cure group were treated significantly earlier than those in the treatment failure group (P < 0.001). Furthermore, even in cases of umbilical hernia non-closure, surgical repair was easier after adhesive strapping. Adhesive strapping represents a promising treatment for umbilical hernia. To achieve the best results, adhesive strapping should be initiated as early as possible. © 2017 Japan Pediatric Society.

  1. Umbilical Hernia Repair: Analysis After 934 Procedures.

    PubMed

    Porrero, José L; Cano-Valderrama, Oscar; Marcos, Alberto; Bonachia, Oscar; Ramos, Beatriz; Alcaide, Benito; Villar, Sol; Sánchez-Cabezudo, Carlos; Quirós, Esther; Alonso, María T; Castillo, María J

    2015-09-01

    There is a lack of consensus about the surgical management of umbilical hernias. The aim of this study is to analyze the medium-term results of 934 umbilical hernia repairs. In this study, 934 patients with an umbilical hernia underwent surgery between 2004 and 2010, 599 (64.1%) of which were evaluated at least one year after the surgery. Complications, recurrence, and the reoperation rate were analyzed. Complications were observed in 5.7 per cent of the patients. With a mean follow-up time of 35.5 months, recurrence and reoperation rates were 3.8 per cent and 4.7 per cent, respectively. A higher percentage of female patients (60.9 % vs 29 %, P = 0.001) and a longer follow-up time (47.4 vs 35 months, P = 0.037) were observed in patients who developed a recurrence. No significant differences were observed between complications and the reoperation rate in patients who underwent Ventralex(®) preperitoneal mesh reinforcement and suture repair; however, a trend toward a higher recurrence rate was observed in patients with suture repair (6.5 % vs 3.2 %, P = 0.082). Suture repair had lower recurrence and reoperation rates in patients with umbilical hernias less than 1 cm. Suture repair is an appropriate procedure for small umbilical hernias; however, for larger umbilical hernias, mesh reinforcement should be considered.

  2. Short communication: The effect of 4 antiseptic compounds on umbilical cord healing and infection rates in the first 24 hours in dairy calves from a commercial herd.

    PubMed

    Robinson, A L; Timms, L L; Stalder, K J; Tyler, H D

    2015-08-01

    The objective of this study was to compare the effect of 4 antiseptic compounds on the healing rate and incidence of infection of umbilical cords in newborn calves (n=60). Late gestation Jersey cows were monitored at a commercial farm (Sioux Jersey, Salix, IA) and newborn purebred (n=30) and crossbred (n=30) calves were obtained within 30min after birth. Calves were alternately assigned by birth order to 4 treatment groups: 7% tincture of iodine, 0.1% chlorine created using a novel chlorine disinfectant technology, chlorohexidine gluconate 4.0% wt/vol, and 10% trisodium citrate. Prior to dipping (within 30min of birth), diameter of the umbilical cords (as an indicator of cord drying and healing) were determined using digital calipers. In addition, as an indicator of umbilical infections, surface temperature of the umbilical stump (along with a reference point at the midpoint of the sternum) was determined using a dual-laser infrared thermometer. These measurements were all repeated at 24±1 h of age. All data were analyzed using mixed model methods. All models included fixed effects of breed (Jersey or Jersey cross), sex (bull or heifer), and treatment. Fixed effect interactions were not included in the statistical model due to the relatively small sample size. No treatment differences were noted for healing rate of umbilical cords. Initially, mean umbilical cord diameter was 22.84±3.89mm and cords healed to a mean diameter of 7.64±4.12mm at 24 h of age. No umbilical infections were noted for calves on any treatment during the course of this study. Mean surface temperature of the umbilical stump was 33.1±2.2°C at birth (1.5±1.6°C higher than the sternal reference temperature), and at 24±1 h of age the mean temperature of the umbilical stump was 33.0±4.3°C (0.5±1.8°C lower than the sternal reference temperature). These data suggest that these antiseptic compounds are equally effective for preventing infections and permitting healing of the umbilical cord when used within 30min of birth. Copyright © 2015 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  3. Acoustic perfect absorber based on metasurface with deep sub-wavelength thickness (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Assouar, Badreddine; Li, Yong

    2016-04-01

    The concept of the coiling up space, based on which artificial structures could exhibit extreme acoustic properties, such as high refractive index, double negativity, near-zero index, etc., have been investigated intensively recently due to the fascinating underlying physics and diverse potential applications [1-3]. One of the most important functionality is the ability to shrink bulky structures into deep sub-wavelength scale. It is therefore intuitive to prospect that the concept of coiling up space, if could be extended into the perforated system, will benefit to significantly reduce the total thickness while keeping total absorption. Conventional acoustic absorbers require a structure with a thickness comparable to the working wavelength, resulting major obstacles in real applications in low frequency range. We present a metasurface-based perfect absorber capable of achieving the total absorption of acoustic wave in extremely low frequency region. The metasurface possessing a deep sub-wavelength thickness down to a feature size of ~ lambda/223 is composed of a perforated plate and a coiled coplanar air chamber. Simulations based on fully coupled acoustic with thermodynamic equations and theoretical impedance analysis are utilized to reveal the underlying physics and the acoustic performances, showing an excellent agreement. Our realization should have high impact on amount of applications due to the extremely thin thickness, easy fabrication and high efficiency of the proposed structure. References 1. Z. Liang and J. Li, Phys. Rev. Lett. 108, 114301 (2012). 2. Y. Li, B. Liang, X. Tao, X. F. Zhu, X. Y. Zou, and J. C. Cheng, Appl. Phys. Lett. 101, 233508 (2012). 3. Y. Xie, W. Wang, H. Chen, A. Konneker, B. I. Popa, and S. A. Cummer, Nat. Commun. 5, 5553 (2014).

  4. Incarcerated umbilical hernia in children.

    PubMed

    Chirdan, L B; Uba, A F; Kidmas, A T

    2006-02-01

    Umbilical hernia is common in children. Complications from umbilical hernias are thought to be rare and the natural history is spontaneous closure within 5 years. A retrospective analysis was performed of the medical records of a series of 23 children who presented with incarcerated umbilical hernias at our institution over an 8-year period. Fifty-two children with umbilical hernias were seen in the hospital over the period. Twenty-three (44.2%) had incarceration. Seventeen (32.7%) had acute incarceration while 6 (11.5%) had recurrent incarceration. There were 16 girls and 7 boys. The ages of the children with acute incarceration ranged from 3 weeks to 12 years (median 4 years), while the ages of those with recurrent incarceration ranged from 3-15 years (median 8.5 years). Incarceration occurred in hernias of more than 1.5 cm in diameter (in those whose defect size was measured). Twenty-one children (15 with acute and all six with recurrent incarceration) underwent repair of the umbilical hernia using standard methods. The parents of two children with acute incarceration declined surgery after spontaneous reduction of the hernia in one and taxis in the other. One boy had gangrenous bowel containing Meckel's diverticulum inside the sac, for which bowel resection with end-to-end anastomosis was done. Operation led to disappearance of pain in all 6 children with recurrent incarceration. Superficial wound infection occurred in one child. There was no mortality. Incarcerated umbilical hernia is not as uncommon as thought. Active observation of children with umbilical hernia is necessary to prevent morbidity from incarceration.

  5. Predicting intrapartum fetal compromise using the fetal cerebro-umbilical ratio.

    PubMed

    Sabdia, S; Greer, R M; Prior, T; Kumar, S

    2015-05-01

    The aim of this study was to explore the association between the cerebro-umbilical ratio measured at 35-37 weeks and intrapartum fetal compromise. This retrospective cross sectional study was conducted at the Mater Mothers' Hospital in Brisbane, Australia. Maternal demographics and fetal Doppler indices at 35-37 weeks gestation for 1381 women were correlated with intrapartum and neonatal outcomes. Babies born by caesarean section or instrumental delivery for fetal compromise had the lowest median cerebro-umbilical ratio 1.60 (IQR 1.22-2.08) compared to all other delivery groups (vaginal delivery, emergency delivery for failure to progress, emergency caesarean section for other reasons or elective caesarean section). The percentage of infants with a cerebro-umbilical ratio <10th centile that required emergency delivery (caesarean section or instrumental delivery) for fetal compromise was 22%, whereas only 7.3% of infants with a cerebro-umbilical ratio between the 10th-90th centile and 9.6% of infants with a cerebro-umbilical ratio > 90th centile required delivery for the same indication (p < 0.001). A lower cerebro-umbilical ratio was associated with an increased risk of emergency delivery for fetal compromise, OR 2.03 (95% CI 1.41-2.92), p < 0.0001. This study suggests that a low fetal cerebro-umbilical ratio measured at 35-37 weeks is associated with a greater risk of intrapartum compromise. This is a relatively simple technique which could be used to risk stratify women in diverse healthcare settings. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Endothelial cell expression of adhesion molecules is induced by fetal plasma from pregnancies with umbilical placental vascular disease.

    PubMed

    Wang, Xin; Athayde, Neil; Trudinger, Brian

    2002-07-01

    To test the hypothesis that local production with spill into the fetal circulation of factor(s) injurious to endothelium is responsible for the vascular pathology present when the umbilical artery Doppler study is abnormal. Expression of adhesion molecules is a feature of endothelial cell activation. Case-control study. University teaching hospital. Fetal plasma was collected from 27 normal pregnancies, 39 pregnancies with umbilical placental vascular disease defined by abnormal umbilical artery Doppler and 11 pregnancies with pre-eclampsia and normal umbilical artery Doppler. Isolated and cultured human umbilical vein endothelial cells from normal pregnancies were incubated with fetal plasma from three study groups. mRNA expression of intercellular cell adhesion molecule-1 (ICAM-1), vascular cell adhesion molecule-1 (VCAM-1) and platelet-endothelial cell adhesion molecule-1 (PECAM-1) were assessed by reverse transcription-polymerase chain reaction. To confirm the occurrence of this in vivo, we measured the levels of soluble fractions of sICAM-1, sVCAM-1 and sPECAM-1 in the fetal circulation in the fetal plasma used for endothelial cell incubation. The mRNA expression of ICAM-1 [median 1.1 (interquartile range 0.5-1.9) vs 0.7 (0.3-1.2), P < 0.05] and PECAM-1 [2.1 (1.2-3.0) vs 1.5 (0.7-2.1), P < 0.05] was significantly higher following incubation with fetal plasma from umbilical placental vascular disease compared with the normal group. There was no difference in the expression of VCAM-1 [1.2 (0.9-1.8) vs 1.1 (0.8-1.6), ns]. The group with maternal pre-eclampsia and normal umbilical artery Doppler did not differ from the normal group. In the umbilical placental vascular disease group, the results were similar in the presence or absence of pre-eclampsia. For soluble fractions of the adhesion molecules released into the fetal circulation, we found the levels (ng/mL) of sICAM- I [median 248.5 (interquartile range 197.3-315.7) vs 174.2 (144.5-212.9), P < 0.05] and sPECAM-1 [9.3 (6.2-11.1) vs 6.1 (5.4-7.7), P < 0.05] in fetal plasma to be significantly increased in the presence of umbilical placental vascular disease compared with the normal. Vascular disease in the fetal umbilical placental circulation is associated with an elevation in mRNA expression by endothelial cells of ICAM-1 and PECAM-1. Our study provides evidence for endothelial cell activation and dysfunction in umbilical placental vascular disease. We speculate that the plasma factor(s) affecting the vessels of the umbilical villous tree is locally released by the trophoblast. The occurrence of the maternal syndrome of pre-eclampsia appears to be independent of this.

  7. Mucinous cystadenoma of the appendix presenting as an umbilical hernia: A case report.

    PubMed

    Ren, Bingbing; Meng, Xiangchao; Cao, Z I; Guo, Chunli; Zhang, Zili

    2016-06-01

    Mucinous cystadenoma of the appendix is a rare condition that develops as a result of proliferation of mucin-secreting cells in an occluded appendix. Mucinous cystadenoma of the appendix presenting as an umbilical hernia is a rare clinical entity. The most common causes of this condition are known to be ascites, hepatitis and cirrhosis; however, the patient in the present study, was diagnosed as hepatitis- and cirrhosis-negative, with no history of chronic coughing or constipation. The aim of the present study was to report a rare case of mucinous cystadenoma of the appendix presenting as an umbilical hernia in a 66-year-old female patient. The patient had a 6-month history of a reducible mass in the umbilical region and was diagnosed with umbilical hernia. Computed tomography and ultrasonography were performed and revealed massive ascites. Ultimately, a laparoscopic appendectomy was performed and borderline mucinous appendiceal cystadenoma of low malignant potential was confirmed. In addition, the present study discussed the association between mucinous cystadenoma of the appendix and umbilical hernia, as well as the diagnostic process and treatment strategies.

  8. Mucinous cystadenoma of the appendix presenting as an umbilical hernia: A case report

    PubMed Central

    REN, BINGBING; MENG, XIANGCHAO; CAO, ZI; GUO, CHUNLI; ZHANG, ZILI

    2016-01-01

    Mucinous cystadenoma of the appendix is a rare condition that develops as a result of proliferation of mucin-secreting cells in an occluded appendix. Mucinous cystadenoma of the appendix presenting as an umbilical hernia is a rare clinical entity. The most common causes of this condition are known to be ascites, hepatitis and cirrhosis; however, the patient in the present study, was diagnosed as hepatitis- and cirrhosis-negative, with no history of chronic coughing or constipation. The aim of the present study was to report a rare case of mucinous cystadenoma of the appendix presenting as an umbilical hernia in a 66-year-old female patient. The patient had a 6-month history of a reducible mass in the umbilical region and was diagnosed with umbilical hernia. Computed tomography and ultrasonography were performed and revealed massive ascites. Ultimately, a laparoscopic appendectomy was performed and borderline mucinous appendiceal cystadenoma of low malignant potential was confirmed. In addition, the present study discussed the association between mucinous cystadenoma of the appendix and umbilical hernia, as well as the diagnostic process and treatment strategies. PMID:27313766

  9. Small Intracranial Aneurysm Treatment Using Target (®) Ultrasoft (™) Coils.

    PubMed

    Jindal, Gaurav; Miller, Timothy; Iyohe, Moronke; Shivashankar, Ravi; Prasad, Vikram; Gandhi, Dheeraj

    2016-06-01

    The introduction of small, soft, complex-shaped microcoils has helped facilitate the endovascular treatment of small intracranial aneurysms (IAs) over the last several years. Here, we evaluate the initial safety and efficacy of treating small IAs using only Target(®) Ultrasoft(™) coils. A retrospective review of a prospectively maintained clinical database at a single, high volume, teaching hospital was performed from September 2011 to May 2015. IAs smaller than or equal to 5.0 mm in maximal dimension treated with only Target(®) Ultrasoft(™) coils were included. A total of 50 patients with 50 intracranial aneurysms were included. Subarachnoid hemorrhage from index aneurysm rupture was the indication for treatment in 23 of 50 (46%) cases, and prior subarachnoid hemorrhage (SAH) from another aneurysm was the indication for treatment in eight of 50 (16%) cases. The complete aneurysm occlusion rate was 70% (35/50), the minimal residual aneurysm rate was 14% (7/50), and residual aneurysm rate was 16% (8/50). One intraoperative aneurysm rupture occurred. Three patients died during hospitalization from clinical sequelae of subarachnoid hemorrhage. Follow-up at a mean of 13.6 months demonstrated complete aneurysm occlusion in 75% (30/40) of cases, near complete occlusion in 15% (6/40) of cases, and residual aneurysm in 10% (4/40) of cases, all four of which were retreated. Our initial results using only Target(®) Ultrasoft(™) coils for the endovascular treatment of small intracranial aneurysms demonstrate initial excellent safety and efficacy profiles.

  10. Mercury in the Umbilical Cord: Implications for Risk Assessment for Minamata Disease.

    PubMed Central

    Dalgard, C; Grandjean, P; Jorgensen, PJ; Weihe, P

    1994-01-01

    Umbilical cord tissue was obtained from 50 births in the Faroe Islands, where high mercury intake is due to ingestion of pilot whale meat. The mercury concentration correlated significantly with the frequency of maternal whale meat dinners during pregnancy and with mercury concentrations in umbilical cord blood and in maternal hair. The results were compared with published values for mercury in umbilical cord tissue from 12 infants diagnosed with congenital methylmercury poisoning in Minamata, Japan. From the regression coefficients obtained in the Faroese samples, the median umbilical cord mercury concentration of 4.95 nmol/g dry weight in Minamata would correspond to 668 nmol/l cord blood and 114 nmol/g maternal hair. These levels agree well with other evidence of susceptibility of the fetus to increased exposure to methylmercury. Images Figure 1. Figure 2. PMID:9679113

  11. Core Stage Forward Skirt Umbilical Installation onto Mobile Laun

    NASA Image and Video Library

    2017-05-25

    Construction workers assist as a crane lifts the Core Stage Forward Skirt Umbilical up for installation on the mobile launcher tower at NASA's Kennedy Space Center in Florida. The mobile launcher tower will be equipped with a number of lines, called umbilicals that will connect to the Space Launch System (SLS) rocket and Orion spacecraft for Exploration Mission-1 (EM-1). The CSFSU will be located at about the 180-foot level on the tower, above the liquid oxygen tank. The CSFSU is an umbilical that will swing into position to provide connections to the core stage forward skirt of the SLS rocket, and then swing away before launch. Its main purpose is to provide conditioned air/GN2 to the SLS core stage forward skirt cavity. The Ground Systems Development and Operations Program is overseeing installation of the umbilicals.

  12. Core Stage Forward Skirt Umbilical Installation onto Mobile Laun

    NASA Image and Video Library

    2017-05-25

    Cranes and rigging are being used to lift up the Core Stage Forward Skirt Umbilical (CSFSU) for installation on the mobile launcher tower at NASA's Kennedy Space Center in Florida. The mobile launcher tower will be equipped with a number of lines, called umbilicals that will connect to the Space Launch System (SLS) rocket and Orion spacecraft for Exploration Mission-1 (EM-1). The CSFSU will be located at about the 180-foot level on the tower, above the liquid oxygen tank. The CSFSU is an umbilical that will swing into position to provide connections to the core stage forward skirt of the SLS rocket, and then swing away before launch. Its main purpose is to provide conditioned air/GN2 to the SLS core stage forward skirt cavity. The Ground Systems Development and Operations Program is overseeing installation of the umbilicals.

  13. Core Stage Forward Skirt Umbilical Installation onto Mobile Laun

    NASA Image and Video Library

    2017-05-25

    A construction worker welds a metal part during installation of the Core Stage Forward Skirt Umbilical on the mobile launcher tower at NASA's Kennedy Space Center in Florida. The mobile launcher tower will be equipped with a number of lines, called umbilicals that will connect to the Space Launch System (SLS) rocket and Orion spacecraft for Exploration Mission-1 (EM-1). The CSFSU will be located at about the 180-foot level on the tower, above the liquid oxygen tank. The CSFSU is an umbilical that will swing into position to provide connections to the core stage forward skirt of the SLS rocket, and then swing away before launch. Its main purpose is to provide conditioned air/GN2 to the SLS core stage forward skirt cavity. The Ground Systems Development and Operations Program is overseeing installation of the umbilicals.

  14. Core Stage Forward Skirt Umbilical Installation onto Mobile Laun

    NASA Image and Video Library

    2017-05-25

    Construction workers assist as a crane lifts the Core Stage Forward Skirt Umbilical into position for installation on the mobile launcher tower at NASA's Kennedy Space Center in Florida. The mobile launcher tower will be equipped with a number of lines, called umbilicals that will connect to the Space Launch System (SLS) rocket and Orion spacecraft for Exploration Mission-1 (EM-1). The CSFSU will be located at about the 180-foot level on the tower, above the liquid oxygen tank. The CSFSU is an umbilical that will swing into position to provide connections to the core stage forward skirt of the SLS rocket, and then swing away before launch. Its main purpose is to provide conditioned air/GN2 to the SLS core stage forward skirt cavity. The Ground Systems Development and Operations Program is overseeing installation of the umbilicals.

  15. Spacecraft automatic umbilical system

    NASA Technical Reports Server (NTRS)

    Goldin, R. W.; Jacquemin, G. G.; Johnson, W. H.

    1981-01-01

    An umbilical system design is described that incorporates all the features specified for a power system to payload interconnect capability. A proof-of-concept prototype of the umbilical system was built to determine experimentally the suitability of the threading characteristics of the ram mechanism and to verify freedom from cross threading. It is concluded that Berthing systems that utilize remote manipulator systems (RMS) can be simplified by using RMS targets, closed circuit TV cameras, tie into the RMS control system, and grapple-fixture and end-effector-like capture and secure mechanisms. To effect a remotely controlled umbilical interconnect in proximity with a manned spacecraft and to provide for extravehicular activity backup and maintenance capabilities, 18 different mechanisms are found to be necessary. The weight impact of proving for maintenance capability in a large multiple connector umbilical system was found to be in the order of +60 percent.

  16. Generation of mesenchymal stromal cells in the presence of platelet lysate: a phenotypic and functional comparison of umbilical cord blood- and bone marrow-derived progenitors

    PubMed Central

    Avanzini, Maria Antonietta; Bernardo, Maria Ester; Cometa, Angela Maria; Perotti, Cesare; Zaffaroni, Nadia; Novara, Francesca; Visai, Livia; Moretta, Antonia; Del Fante, Claudia; Villa, Raffaella; Ball, Lynne M.; Fibbe, Willem E.; Maccario, Rita; Locatelli, Franco

    2009-01-01

    Background Mesenchymal stromal cells are employed in various different clinical settings in order to modulate immune response. However, relatively little is known about the mechanisms responsible for their immunomodulatory effects, which could be influenced by both the cell source and culture conditions. Design and Methods We tested the ability of a 5% platelet lysate-supplemented medium to support isolation and ex vivo expansion of mesenchymal stromal cells from full-term umbilical-cord blood. We also investigated the biological/functional properties of umbilical cord blood mesenchymal stromal cells, in comparison with platelet lysate-expanded bone marrow mesenchymal stromal cells. Results The success rate of isolation of mesenchymal stromal cells from umbilical cord blood was in the order of 20%. These cells exhibited typical morphology, immunophenotype and differentiation capacity. Although they have a low clonogenic efficiency, umbilical cord blood mesenchymal stromal cells may possess high proliferative potential. The genetic stability of these cells from umbilical cord blood was demonstrated by a normal molecular karyotype; in addition, these cells do not express hTERT and telomerase activity, do express p16ink4a protein and do not show anchorage-independent cell growth. Concerning alloantigen-specific immune responses, umbilical cord blood mesenchymal stromal cells were able to: (i) suppress T- and NK-lymphocyte proliferation, (ii) decrease cytotoxic activity and (iii) only slightly increase interleukin-10, while decreasing interferon-γ secretion, in mixed lymphocyte culture supernatants. While an indoleamine 2,3-dioxygenase-specific inhibitor did not reverse mesenchymal stromal cell-induced suppressive effects, a prostaglandin E2-specific inhibitor hampered the suppressive effect of both umbilical cord blood- and bone marrow-mesenchymal stromal cells on alloantigen-induced cytotoxic activity. Mesenchymal stromal cells from both sources expressed HLA-G. Conclusions Umbilical cord blood- and bone marrow-mesenchymal stromal cells may differ in terms of clonogenic efficiency, proliferative capacity and immunomodulatory properties; these differences may be relevant for clinical applications. PMID:19773264

  17. Attitudes of Swiss mothers toward unrelated umbilical cord blood banking 6 months after donation.

    PubMed

    Danzer, Enrico; Holzgreve, Wolfgang; Troeger, Carolyn; Kostka, Ulrike; Steimann, Sabine; Bitzer, Johanes; Gratwohl, Alois; Tichelli, André; Seelmann, Kurt; Surbek, Daniel V

    2003-05-01

    During the past decade, the use of umbilical cord blood (CB) as a source of transplantable hematopoietic stem cells has been increasing. Little is known about the psychosocial consequences that later affect parents after unrelated CB donation. The objective of this study was to evaluate the attitudes of mothers toward unrelated donation of umbilical CB for transplantation 6 months after giving birth. A prospective study was performed with a standardized, anonymous questionnaire distributed to 131 women 6 months after CB donation. The questionnaire included topics concerning views about the ethical accuracy of having donated CB, emotional responses after donation, concerns about genetic testing and research with CB samples, attitude toward anonymity between her child and possible unrelated CB recipient, and willingness to repeatedly donate umbilical CB in a next pregnancy. The vast majority (96.1%) stated that they would donate umbilical CB again, and all respondents were certain that their decision to have donated umbilical CB was ethical. With regard to the potential risks of genetic testing and "experimentation" of umbilical CB, a significant correlation (p = 0.01) was found between negative attitudes and the decision not to donate umbilical CB again. Additionally, it was observed that women who had a negative experience concerning the donation of CB would not donate again (p = 0.004). This study shows a high degree of satisfaction of unrelated umbilical CB donation for banking in women 6 months after delivery. Despite a well-performed and detailed informed consent procedure, one of the ongoing issues for the donators in CB banking involves the concern regarding of improper use of the cells, such as genetic testing or experimentation. Accurate and detailed counseling of pregnant women and their partners therefore maximizes the likelihood that they will donate CB for unrelated banking. These data provide a basis for the improvement of donor selection procedures and public education regarding the use of CB for banking and transplantation.

  18. [Rare umbilical anomalies].

    PubMed

    Kysucan, J; Malý, T; Neoral, C

    2010-12-01

    Umbilicus is a scar, which is the place of the previous merger of the fetus with the umbilical cord. After birth, it has no known function, however, unless the umbilical annulus is completely closed, umbilical hernia may occur. Umbilical scar is also an area where may occur a number of anomalies that may be present alone or together with umbilical hernia. Failure of involution leads to persistence of omphalomesenteric duct and urachal remnants. These embryonic remnants may cause more or less significant clinical problems, or may be completely asymptomatic and may be diagnosed at random. The authors present their own group of patients who were diagnosed and dealt with the defect omphalomesenteric duct or urachus. In past 7 years we observed 35 children with these abnormalities. A large group of patients represents incidental findings during elective surgery for umbilical hernia. Another large group are patients with symptomatic or asymptomatic Meckel's diverticulum. The anatomical observations, clinical manifestations, complications and treatment of these anomalies are mentioned. A total of 35 children were found with these birth defects. In 23 cases we observed omphalomesenteric duct disorders and 12 urachal remnants were reported. Of these, 12 abnormalities were found incidentally during elative procedure for umbilical hernia. Asymptomatic or symptomatic Meckel's diverticulum appeared in 16 cases. Surgical treatment included resection or exstirpation, if urachal anomaly was accompanied then partial resection of the bladder vertex was added. Postoperative complications emerged in 4 cases, three times it was ileus from adhesions 6 months after surgery, once postoperative cystitis appeared and was treated conservatively. Birth abnormalities of the umbilicus are relatively rare diseases that may occur in the pediatric population. Omfalomesenteric duct and urachal anomalies constitute a major group of these congenital disorders and are often associated with umbilical hernia. They can be diagnosed soon after birth or later in life. Surgical treatment involves excision or radical exstirpation to prevent early or late complications (urachal carcinoma in adulthood).

  19. Profile of paediatric umbilical hernias managed at Federal Medical Centre Umuahia.

    PubMed

    Ezomike, U O; Ituen, M A; Ekpemo, S C; Eke, C B; Eke, B C

    2012-01-01

    Umbilical hernias are common in children but many resolve spontaneously within the first five years of life. Most umbilical herniorrhaphies in our environment are due to symptomatic hernias which constitute a small percentage of all umbilical hernias. A retrospective review of all pediatric patients with UH treated at Federal Medical Centre Umuahia, Abia State from February 2001 to February 2011. There were 22 patients but only 20 of the folders were found and analyzed. They were made up of 11 males and 9 females with a mean age of 6.19 +/- 0.83 years and median age of 6 years. Nine(7 males and 2 females) had acute incarcerations, nine (3 males and 6 females) had recurrent umbilical pains without incarceration and two (1 male and 1 female) had recurrent incarcerations. Age range for acute incarceration was 2-8 years (mean: 4.69 years, median: 4 years); recurrent umbilical pains was 4 months -15 years (mean: 7.7 years, median: 8 years) and for recurrent incarceration 2-10 years (mean: 6 years). All had standard umbilical hernia repairs except one whose parents declined surgery after reduction of acute incarceration. One patient with acute incarceration had gangrenous bowel with hernia sac abscess and was offered bowel resection with end-to-end anastomosis. On short-term follow-up, the symptoms resolved in all the patients following surgery. Five patients had six complications: 1 exuberant granulation tissue, 2 stitch reactions, 2 superficial wound dehiscence and one superficial wound infection. There were no mortalities and no recurrence on short-term follow-up. Only one patient (5%) registered under the National Health Insurance Scheme (NHIS). Active observation of all umbilical hernias at all ages will ensure early detection of complications and prompt treatment. Elective repair of umbilical hernias in patientsabove five years with fascia defect greater than 1.5cm is encouraged. Comprehensive NHIS will ensure early presentation and reduced complications.

  20. Umbilical cord rupture: a case report and review of literature.

    PubMed

    Naidu, Madhusudhan; Nama, Vivek; Karoshi, Mahantesh; Kakumani, Vijayasri; Worth, Richard

    2007-01-01

    The umbilical cord acts as a mechanical conduit between the fetus and placenta, allowing movement of water and nutrient substances between the fetal circulation and the amniotic fluid. Complications can occur antenatally or intranatally and are usually acute events that require immediate delivery to prevent intrauterine death. Even though the majority of the cord complications are unpreventable, significant improvement in perinatal mortality and morbidity can be achieved if such an event can be predicted. Umbilical cord rupture is not uncommon, but significantly underreported. We present an unusual cause of umbilical cord rupture and a review of literature.

  1. Engraftment of gene-modified umbilical cord blood cells in neonates with adenosine deaminase deficiency

    PubMed Central

    Kohn, Donald B.; Weinberg, Kenneth I.; Nolta, Jan A.; Heiss, Linda N.; Lenarsky, Carl; Crooks, Gay M.; Hanley, Mary E.; Annett, Geralyn; Brooks, Judith S.; El-Khoureiy, Anthony; Lawrence, Kim; Wells, Susie; Moen, Robert C.; Bastian, John; Williams-Herman, Debora E.; Elder, Melissa; Wara, Diane; Bowen, Thomas; Hershfield, Michael S.; Mullen, Craig A.; Blaese, R. Michael; Parkman, Robertson

    2010-01-01

    Haematopoietic stem cells in umbilical cord blood are an attractive target for gene therapy of inborn errors of metabolism. Three neonates with severe combined immunodeficiency were treated by retroviral-mediated transduction of the CD34+ cells from their umbilical cord blood with a normal human adenosine deaminase complementary DNA followed by autologous transplantation. The continued presence and expression of the introduced gene in leukocytes from bone marrow and peripheral blood for 18 months demonstrates that umbilical cord blood cells may be genetically modified with retroviral vectors and engrafted in neonates for gene therapy. PMID:7489356

  2. Umbilical Hernia Repair: Overview of Approaches and Review of Literature.

    PubMed

    Appleby, Paul W; Martin, Tasha A; Hope, William W

    2018-06-01

    Umbilical hernias are ubiquitous, and surgery is indicated in symptomatic patients. Umbilical hernia defects can range from small (<1 cm) to very large/complex hernias, and treatment options should be tailored to the clinical situation. Open, laparoscopic, and robotic options exist for repair, with each having its advantages and disadvantages. In general, mesh should be used for repair, because it has been shown to decrease recurrence rates, even in small hernias. Although outcomes are generally favorable after umbilical hernia repairs, some patients have chronic complaints that are mostly related to recurrences. Copyright © 2018 Elsevier Inc. All rights reserved.

  3. Obstructed Umbilical Hernia: A Normal Presentation with Abnormal Contents

    PubMed Central

    P Agrawal, Vijay; Narasimhaprasad, Ashwin

    2015-01-01

    Umbilical hernia is a common problem encountered in children. The rarity of finding cecum and appendix is probably due to the fact that the appendix is seldom found in the proximity of the umbilicus. It would, therefore, appear worthwhile to report the occurrence of cecum and an inflamed appendix with Ladd’s bands in an umbilical hernia of a child. The last case with similar presentation was presented in 1950s. How to cite this article Agrawal VP, Shetty NS, Narasimhaprasad A. Obstructed Umbilical Hernia: A Normal Presentation with Abnormal Contents. Euroasian J Hepato-Gastroenterol 2015;5(2):110-111. PMID:29201704

  4. [Umbilical cord collision in the first trimester in a monoamniotic twin pregnancy--does it really matter?].

    PubMed

    Ropacka-Lesiak, Mariola; Lebioda, Anna; Breborowicz, Grzegorz

    2012-09-01

    A case of an umbilical cord collision diagnosed in the first trimester of a monochorionic monoamniotic twin pregnancy is presented. An intensive surveillance included ultrasound monitoring with color and spectral Doppler and fetal echocardiography. The first signs of fetal distress were observed at 31 weeks of gestation. The brain sparing effect as well as a periodic appearance of the "notch" in the wave forms obtained from the umbilical artery from the collision region were observed. In the first ultrasound scan there were no abnormalities in twin I. In contrast, in twin II a vascular resistance in the umbilical artery was at the upper limit for the gestational age. Five days later, decreased vascular resistance in the middle cerebral artery, which fluctuated at the lower limit, was noticed in twin II. After the next four days, PI in the middle cerebral artery decreased below the lower limit and tricuspid regurgitation appeared. In twin I the vascular resistance in the umbilical artery increased and remained at the upper limit of the reference ranges. Cardiotocographic records did not reveal signs of fetal distress. After a week the signs of brain sparing effect were visible in both fetuses. However, twin II showed features of umbilical cord clamping in the form of abnormal blood flow waveforms in the umbilical artery ("notch"). Therefore, despite the absence of signs of fetal distress in CTG in monochorionic monoamniotic twins with growth discordance of 20% and exponents of periodical clamping of the umbilical cord in twin II at 34 weeks, the decision to perform a caesarean section was made. The patient gave birth to two daughters (twin I: weight 1780g, Ap 10, pH 7.39, 7.40, BE -3.0, -2.6, and twin II: weight 1860g, Ap 10, pH 7.29, 7.35, BE -1.4, -2.4). During the delivery the umbilical cords collision was found at the region close to the body of twins. This case presents the possibility of using ultrasound and Doppler in the early diagnosis, monitoring and surveillance of pregnancies complicated by umbilical cords collision in monochorionic monoamniotic twins from the first trimester. Application of these methods allowed a safe monitoring of the fetuses and the identification of the onset of the cords collision. This in turn allowed the achievement of fetal maturity at 34 weeks, when both the risk of death and neonatal morbidity are significantly minimized. The use of Doppler blood flow velocimetry allowed the diagnosis of umbilical cords tightening before there were any signs of cardiac dysfunction in the CTG. This enabled to determine the most favorable, earlier time for delivery. The paper presents diagnostic management and surveillance in monochorionic monoamniotic pregnancy complicated by umbilical cord collision since the early pregnancy.

  5. Troponin T and Pro–B-Type Natriuretic Peptide in Fetuses of Type 1 Diabetic Mothers

    PubMed Central

    Russell, Noirin E.; Higgins, Mary F.; Amaruso, Michael; Foley, Michael; McAuliffe, F.M.

    2009-01-01

    OBJECTIVE Cardiomyopathy is noted in up to 40% of infants of diabetic mothers, and the exact mechanisms are unknown. The aim of this study was to determine whether fetal serum markers of cardiac function differ between normal and type 1 diabetic pregnancies and to examine the relationship between these markers and fetal cardiac structure and function. RESEARCH DESIGN AND METHODS This was a prospective observational study of 45 type 1 diabetic pregnancies and 39 normal pregnancies. All participants had concentrations of fetal pro–B-type natriuretic peptide (proBNP) and troponin-T (TnT) measured at the time of delivery. All patients with type 1 diabetes had Doppler evaluation of the umbilical artery, middle cerebral artery, and ductus venosus in the third trimester, and a subset (n = 21) had detailed fetal echocardiograms performed in each trimester. RESULTS Fetal proBNP and TnT concentrations were higher in the diabetic cohort than in the normal cohort (P < 0.05). ProBNP correlated positively with interventricular septum thickness (P < 0.05) but not with cardiac function indexes in the third trimester. In patients with poor glycemic control, there was a significant positive correlation (P < 0.05) between fetal TnT and the third trimester umbilical artery pulsatility index. There were also increased levels of fetal TnT in infants with poor perinatal outcome (P < 0.05). CONCLUSIONS Biochemical markers of cardiac dysfunction are elevated in infants of diabetic mothers, especially those with cardiomyopathy or poor perinatal outcome. Hyperglycemia in early pregnancy may affect myocardial and placental development, thus contributing to the susceptibility to hypoxia seen in these infants. PMID:19690080

  6. The effect of Ramadan fasting on fetal development.

    PubMed

    Karateke, Atilla; Kaplanoglu, Mustafa; Avci, Fazil; Kurt, Raziye Keskin; Baloglu, Ali

    2015-01-01

    To evaluate the effects of Ramadan fasting on fetal development and outcomes of pregnancy. We performed this study in Antakya State Hospital of Obstetrics and Child Care, between 28 June 2014 and 27 July 2014 (during the month of Ramadan). A total of two hundred forty healthy pregnant women who were fasting during Ramadan, were included in the groups. The three groups were divided according to the trimesters. The each group was consisted of 40 healthy pregnant women with fasting and 40 healthy pregnant women without fasting. For evaluating the effects of Ramadan on fetus, ultrasonography was performed on all pregnant women in the beginning and the end of Ramadan. We used the essential parameters for the following measurements: increase of fetal biparietal diameter (BPD), increase of fetal femur length (FL), increase of estimated fetal body weight (EFBW), fetal biophysical profile (BPP), amniotic fluid index (AFI), and umbilical artery systole/diastole (S/D) ratio. No significant difference was found between the two groups for the fetal age, maternal weight gain (kilogram), estimated fetal weight gain (EFWG), fetal BPP, AFI, and umbilical artery S/D ratio. On the other hand, a statistically significant increase was observed in maternal weight in the second and third trimesters and a significant increase was observed in the amniotic fluid index in second trimester. In Ramadan there was no bad fetal outcome between pregnant women with fasting and pregnant women without fasting. Pregnant women who want to be with fast, should be examined by doctors, adequately get breakfast before starting to fast and after the fasting take essential calori and hydration. More comprehensive randomized studies are needed to explain the effects of fasting on the pregnancy and fetal outcomes.

  7. The impact of maternal plasma volume expansion and antihypertensive treatment with intravenous dihydralazine on fetal and maternal hemodynamics during pre-eclampsia: a clinical, echo-Doppler and viscometric study.

    PubMed

    Boito, S M E; Struijk, P C; Pop, G A M; Visser, W; Steegers, E A P; Wladimiroff, J W

    2004-04-01

    To establish the effects of plasma volume expansion (PVE) followed by intravenous dihydralazine (DH) administration on maternal whole blood viscosity (WBV) and hematocrit, uteroplacental and fetoplacental downstream impedance and umbilical venous (UV) volume flow in pre-eclampsia. In 13 pre-eclamptic women maternal and fetal hemodynamics were established by means of combined measurement of maternal arterial blood pressure (BP), WBV, hematocrit and uterine artery (UtA) resistance index (RI) in addition to umbilical artery (UA) pulsatility index (PI) and UV volume flow obtained from UV vessel area and UV time-averaged flow velocity. In each woman all parameters were measured four times at baseline, after PVE, after DH and 24 h after the start of treatment. Maternal diastolic BP, hematocrit and WBV display a significant reduction after PVE. In the fetus UA PI decreases significantly whereas a significant increase in UV cross-sectional area was detected. After maternal DH administration, arterial systolic and diastolic BP and UA PI show a significant decrease compared with the measurements following PVE. At 24 h, only maternal systolic and diastolic BP display a significant further decrease. No significant changes were established for the UtA RI, UV time-averaged velocity and UV volume flow during the entire study period. During pre-eclampsia, maternal PVE followed by DH administration results in a significant reduction in maternal diastolic BP, maternal hematocrit and WBV. Maternal PVE is associated with a significant increase in UV cross-sectional area and a non-significant rise of 11% in UV volume flow. Maternal DH administration does not result in any change in UV cross-sectional area. However, UA PI decreases significantly after both PVE and DH treatment. Copyright 2004 ISUOG.

  8. SUPRAPUBIC LAPAROSCOPIC CHOLECYSTECTOMY: TECHNIQUE AND PRELIMINARY RESULTS

    PubMed Central

    SALES, Leonardo Adolpho S.; PINTO, João Odilo G.; QUEIROZ, Carlos Eduardo F.; CASTRO, Marcelo; DOURADO, Paulo Henrique F.; PINHEIRO, Fernando Antonio S.

    2014-01-01

    Background The minimally invasive abdominal surgery has evolved to reduce portals, culminating with a single incision and natural orifice operation. However, these methods are still expensive, difficult to implement and with questionable aesthetic results. Aim To present the standardization and preliminary results of a technique for performing laparoscopic suprapubic access by the principle which was called the Supra Pubic Endoscopic Surgery for cholecystectomy. Method The average body mass index of patients, the mean operative time, clinical data of the postoperative complications and quality of life were prospectively studied. The operation incisions consisted of: A) umbilical for instrumental dissection and clipping; B) in the right groin for handling and gallbladder gripping; C) suprapubic for the camera. With the patient in reverse Trendelenburg and left lateral decubitus, the operation flew by the camera trocar in C, proceeding with dissection and isolation of the biliary pedicle, identification of cystic duct and artery, with usual instrumentation. Transcystic intraoperative cholangiography was performed in all cases in which there were indications. The procedure was completed with clipping and sectioning of the cystic duct and artery, retrograde resection of the gallbladder and extracting it by the umbilical trocar incision under direct vision. Results Thirty patients undergone this surgical procedure between March and June 2012 and were evaluated. The mean age was 40.7 years and the indications were typical biliary colic in 18 cases (60 %), cholecystitis in five cases (16.6 %), biliary pancreatitis in one case (3.3%); polyp in three cases (10%) and obstructive jaundice at three cases (10%). The average body mass index was 27.8 (23.1-35.1) and surgical time ranged between 24 and 70 minutes. Conclusion The technique proved to be feasible and safe , with no significant complications, and satisfactory cosmetic results. PMID:24676293

  9. Anesthetic management of super-morbidly obese parturients for cesarean delivery with a double neuraxial catheter technique: a case series.

    PubMed

    Polin, C M; Hale, B; Mauritz, A A; Habib, A S; Jones, C A; Strouch, Z Y; Dominguez, J E

    2015-08-01

    Parturients with super-morbid obesity, defined as body mass index greater than 50kg/m(2), represent a growing segment of patients who require anesthetic care for labor and delivery. Severe obesity and its comorbid conditions place the parturient and fetus at greater risk for pregnancy complications and cesarean delivery, as well as surgical and anesthetic complications. The surgical approach for cesarean delivery in these patients may require a supra-umbilical vertical midline incision due to a large pannus. The dense T4-level of spinal anesthesia can cause difficulties with ventilation for the obese patient during the procedure, which can be prolonged. Patients also may have respiratory complications in the postoperative period due to pain from the incision. We describe the anesthetic management of three parturients with body mass index ranging from 73 to 95kg/m(2) who had a cesarean delivery via a supra-umbilical vertical midline incision. Continuous lumbar spinal and low thoracic epidural catheters were placed in each patient for intraoperative anesthesia and postoperative analgesia, respectively. Continuous spinal catheters were dosed with incremental bupivacaine boluses to achieve surgical anesthesia. In one case, the patient required respiratory support with non-invasive positive pressure ventilation. Two cases were complicated by intraoperative hemorrhage. All patients had satisfactory postoperative analgesia with a thoracic epidural infusion. None suffered postoperative respiratory complications or postdural puncture headache. The use of a continuous lumbar spinal catheter and a low thoracic epidural provides several advantages in the anesthetic management of super-morbidly obese parturients for cesarean delivery. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Infection of internal umbilical remnant in foals by Clostridium sordellii.

    PubMed

    Ortega, J; Daft, B; Assis, R A; Kinde, H; Anthenill, L; Odani, J; Uzal, F A

    2007-05-01

    Omphalitis and the resulting septicemia contribute to perinatal mortality in several animal species. In foals, the most important causes of omphalitis are Escherichia coli and Streptococcus zooepidemicus. However to date, no information has been published about the role of Clostridium sordellii in these infections. In this paper, we describe 8 cases of perinatal mortality in foals associated with internal umbilical remnant infection by C. sordellii. The foals studied were between 12 and 21 days old at the time of death, and various breeds were represented in the group. Five of the foals were male and 3 were female. The diagnosis was established on the basis of the detection of C. sordellii by 3 methods (culture, fluorescent antibody test, and immunohistochemistry) and on gross and histopathologic findings. All foals had acute peritonitis, and the internal umbilical remnant was thickened by edema, hemorrhage, and fibrosis. A moderate amount of serosanguinous fluid with fibrin strands was present in the pericardial sac and pleural cavity. Histopathologically, the urachus and umbilical arterial walls were thickened by edema and exhibited hemorrhage, fibrin, and leukocytic infiltration. Gram-positive bacterial rods were observed in subepithelial areas of the urachus, the adventicia of umbilical arteries, and interstitium of the internal umbilical remnant. On the basis of these findings, we suggest that C. sordellii should be considered in the differential diagnosis for infections of the internal umbilical remnant in foals.

  11. PP043. Oxidative stress in the maternal body also affects the fetus in preeclamptic women with fetal growth restriction.

    PubMed

    Watanabe, Kazushi; Iwasaki, Ai; Mori, Toshitaka; Kimura, Chiharu; Matsushita, Hiroshi; Shinohara, Koichi; Wakatsuki, Akihiko

    2013-04-01

    The purpose of the present study was to determine whether oxidative stress occurring in the maternal body also affects the fetus in preeclamptic women with FGR. We ∥@consecutively recruited 17 preeclamptic women with FGR, 16 preeclamptic women without FGR, and 16 healthy pregnant women with uncomplicated pregnancy. We measured concentrations of derivatives of reactive oxygen metabolites (d-ROMs) as a marker of oxygen free radicals in a maternal vein, umbilical artery, and umbilical vein. ∥@Maternal d-ROM levels were higher in preeclamptic groups compared to the control group. Umbilical artery and vein d-ROM levels were elevated in preeclamptic women with FGR compared to the control group. Umbilical artery d-ROM levels were significantly higher than in the vein in preeclamptic women with FGR, but not in those without FGR. Umbilical arterial blood pH was significantly lower in preeclamptic women with FGR. The partial pressure of oxygen (PaO2) in umbilical arterial blood tended to be lower in preeclamptic women with FGR (p=0.08). The partial pressure of carbon dioxide (PaCO2) in umbilical arterial blood was significantly higher in preeclamptic women with FGR. These results indicate that oxidative stress occurring in the maternal body also affects the fetus in preeclamptic women with FGR. Copyright © 2013. Published by Elsevier B.V.

  12. Abnormal umbilical cord Doppler sonograms may predict impending demise in fetuses with sacrococcygeal teratoma. A report of two cases.

    PubMed

    Olutoye, Oluyinka O; Johnson, Mark P; Coleman, Beverly G; Crombleholme, Timothy M; Adzick, N Scott; Flake, Alan W

    2004-01-01

    To identify factors predictive of fetal demise in fetuses with sacrococcygeal teratoma (SCT). The recent management of monochorionic twins discordant for a large SCT and a singleton with a large SCT was reviewed. Serial fetal echocardiography and ultrasonography with Doppler flow measurements documented rapid growth of the SCT in both cases with a relatively modest increase in combined cardiac output. No placentomegaly or hydrops was observed at any time. In both fetuses with SCT, evolution of abnormal umbilical artery waveforms was observed with the ultimate development of reversed end-diastolic umbilical arterial flow that was followed by sudden fetal demise. Death in these 2 fetuses with large SCTs in the absence of placentomegaly/hydrops or hemodynamic changes suggestive of evolving high-output failure suggests a previously unrecognized mechanism of death in fetuses with large rapidly growing SCTs. In these cases, fetal demise may only be heralded by abnormal umbilical artery waveforms that progress to the premorbid observation of reversed diastolic umbilical artery blood flow. Umbilical artery waveform analysis should be closely monitored with other hemodynamic parameters in fetuses with large SCTs. In such fetuses, depending on the gestational age, abnormalities in umbilical artery waveform should be considered indications for early delivery or in utero intervention to prevent fetal demise. Copyright 2004 S. Karger AG, Basel

  13. Abnormal umbilical cord Dopplers may predict impending demise in fetuses with sacrococcygeal teratoma. A report of 2 cases.

    PubMed

    Olutoye, Oluyinka O; Johnson, Mark P; Coleman, Beverly G; Crombleholme, Timothy M; Adzick, N Scott; Flake, Alan W

    2003-01-01

    To identify factors predictive of fetal demise in fetuses with sacrococcygeal teratoma (SCT). The recent management of monochorionic twins discordant for a large SCT and a singleton with a large SCT were reviewed. Serial fetal echocardiography and ultrasonography with Doppler flow measurements documented rapid growth of the SCT in both cases with a relatively modest increase in combined cardiac output. No placentomegaly or hydrops was observed at any time. In both fetuses with SCT, evolution of abnormal umbilical artery waveforms was observed with the ultimate development of reversed end-diastolic umbilical arterial flow that was followed by sudden fetal demise. Death in these 2 fetuses with large SCTs in the absence of placentomegaly/hydrops or hemodynamic changes suggestive of evolving high-output failure suggests a previously unrecognized mechanism of death in fetuses with large rapidly growing SCTs. In these cases, fetal demise may only be heralded by abnormal umbilical artery waveforms that progress to the premorbid observation of reversed diastolic umbilical artery blood flow. Umbilical artery waveform analysis should be closely monitored with other hemodynamic parameters in fetuses with large SCTs. In such fetuses, depending on the gestational age, abnormalities in umbilical artery waveform should be considered indications for early delivery or in utero intervention to prevent fetal demise. Copyright 2003 S. Karger AG, Basel

  14. Umbilical hernias and anterior fontanelle size in Jamaican children.

    PubMed

    Cohen, I P

    1989-06-01

    This cross-sectional study documents the frequent occurrence of umbilical hernias among Jamaican children and suggests, for the first time, that the presence of an umbilical hernia may be associated with larger anterior fontanelle dimensions. It also demonstrates that data about the people a community health officer serves can be recorded during a busy clinic schedule.

  15. The Effect of Prophylactic Phenylephrine and Ephedrine Infusions on Umbilical Artery Blood pH in Women With Preeclampsia Undergoing Cesarean Delivery With Spinal Anesthesia: A Randomized, Double-Blind Trial.

    PubMed

    Higgins, Nicole; Fitzgerald, Paul C; van Dyk, Dominique; Dyer, Robert A; Rodriguez, Natalie; McCarthy, Robert J; Wong, Cynthia A

    2018-06-01

    Spinal anesthesia for cesarean delivery is associated with a high incidence of hypotension. Phenylephrine results in higher umbilical artery pH than ephedrine when used to prevent or treat hypotension in healthy women. We hypothesized that phenylephrine compared to ephedrine would result in higher umbilical artery pH in women with preeclampsia undergoing cesarean delivery with spinal anesthesia. This study was a randomized double-blind clinical trial. Nonlaboring women with preeclampsia scheduled for cesarean delivery with spinal anesthesia at Prentice Women's Hospital of Northwestern Medicine were randomized to receive prophylactic infusions of phenylephrine or ephedrine titrated to maintain systolic blood pressure >80% of baseline. Spinal anesthesia consisted of hyperbaric 0.75% bupivacaine 12 mg, fentanyl 15 µg, and morphine 150 µg. The primary outcome was umbilical arterial blood pH and the secondary outcome was umbilical artery base excess. One hundred ten women were enrolled in the study and 54 per group were included in the analysis. There were 74 and 72 infants delivered in the ephedrine and phenylephrine groups, respectively. The phenylephrine:ephedrine ratio for umbilical artery pH was 1.002 (95% confidence interval [CI], 0.997-1.007). Mean [standard deviation] umbilical artery pH was not different between the ephedrine 7.20 [0.10] and phenylephrine 7.22 [0.07] groups (mean difference -0.02, 95% CI of the difference -0.06 to 0.07; P = .38). Median (first, third quartiles) umbilical artery base excess was -3.4 mEq/L (-5.7 to -2.0 mEq/L) in the ephedrine group and -2.8 mEq/L (-4.6 to -2.2mEq/L) in the phenylephrine group (difference -0.6 mEq/L, 95% CI of the difference -1.6 to 0.3 mEq/L; P = .10). When adjusted for gestational age and infant gender, umbilical artery pH did not differ between groups. There were also no differences in the umbilical artery pH stratified by magnesium therapy or by the severity of preeclampsia. We were unable to demonstrate a beneficial effect of phenylephrine on umbilical artery pH compared with ephedrine. Our findings suggest that phenylephrine may not have a clinically important advantage compared with ephedrine with regard to improved neonatal acid-base status when used to prevent spinal anesthesia-induced hypotension in women with preeclampsia undergoing cesarean delivery.

  16. Umbilical necrosis rates after abdominal-based microsurgical breast reconstruction.

    PubMed

    Ricci, Joseph A; Kamali, Parisa; Becherer, Babette E; Curiel, Daniel; Wu, Winona; Tobias, Adam M; Lin, Samuel J; Lee, Bernard T

    2017-07-01

    Umbilical stalk necrosis represents a rare, yet important complication after abdominal-based microsurgical breast reconstruction, which is both underrecognized and understudied in the literature. Once identified, umbilical reconstruction can be an extremely challenging problem. All consecutive breast free flaps at a single institution from February 2004 to February 2016 were reviewed, excluding non-abdominal-based flaps. Patients were divided based on the development of umbilical necrosis postoperatively. Demographics, surgical characteristics, and other complications were compared between the groups. A total of 918 patients met the inclusion criteria, with 29 developing umbilical necrosis identified (3.2%). Patients developing necrosis tended to be older (49.4 yrs versus 52.9 yrs; P < 0.01); have higher BMI (31.3 versus 27.8; P < 0.01); and were more likely to be smokers (27.5% versus 11.6%; P = 0.01). Umbilical necrosis was also associated with increased flap weight (830 g versus 656 g; P < 0.01), decreased time of perforator dissection (151 min versus 169 min; P = 0.02); bilateral cases (68.9% versus 44.7%; P < 0.01), and increased number of perforators per flap (2.5 versus 2.2; P = 0.03). There was no association with flap type (deep inferior epigastric perforator, superficial inferior epigastric artery, or free TRAM), diabetes, previous abdominal surgery, or use of preoperative imaging. Umbilical necrosis was not associated with any concomitant complications. Umbilical stalk necrosis was found to occur in 3.2% of patients and was associated with several preoperative comorbidities and intraoperative characteristics. This information should help influence intraoperative decision-making to prevent the development of this undesirable complication. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Efficacy of intra-umbilical oxytocin in the management of retained placenta: a randomized controlled trial.

    PubMed

    Samanta, Ajanta; Roy, Samir Ghosh; Mistri, Pallab Kumar; Mitra, Anirban; Pal, Ranjan; Naskar, Animesh; Bhattacharya, Sanjay Kumar; Pal, Partha Pratim; Pande, Arindam

    2013-01-01

    Retained placenta is an important cause of maternal mortality. The present study was aimed to determine the efficacy of umbilical injection of oxytocin as a treatment modality in this condition. This was a single-center randomized controlled trial incorporating 58 women with retained placenta of more than 30 min, equally distributed into two study arms of intra-umbilical injection of oxytocin (50 IU oxytocin diluted with normal saline [NS] to a total volume 30 mL) and intra-umbilical injection of NS (30 mL). Primary outcome was expulsion of the placenta within 30 min following intervention. All the data were analyzed on an intention-to-treat basis. The success rate in the intra-umbilical oxytocin group was 51.72% compared to 20.69% in the control arm. This difference in the primary outcome was statistically significant with a P-value<0.05 (P=0.014) favoring intra-umbilical oxytocin infusion with an efficacy rate of 1.5 and a number-needed-to-treat of 3. The peripartum bleeding complications were more in the NS group with a statistically higher (P<0.001) requirement of extra oxytocin to control post-partum bleeding. There were no differences between the two groups in respect to other secondary outcomes, such as post-partum fever, antibiotic requirement and hospital stay.   Umbilical vein injection of 50IU oxytocin in 30mL of NS delivered effectively via the umbilical cord with milking in cases of retained placenta seems a simple and promising technique to reduce the incidence of a potentially morbid procedure and other complications. © 2012 The Authors. Journal of Obstetrics and Gynaecology Research © 2012 Japan Society of Obstetrics and Gynecology.

  18. Release from quiescence of CD34+ CD38- human umbilical cord blood cells reveals their potentiality to engraft adults.

    PubMed Central

    Cardoso, A A; Li, M L; Batard, P; Hatzfeld, A; Brown, E L; Levesque, J P; Sookdeo, H; Panterne, B; Sansilvestri, P; Clark, S C

    1993-01-01

    Using optimal culture conditions in which the transforming growth factor beta 1 (TGF-beta 1) inhibitory loop has been interrupted by antisense TGF-beta 1 oligonucleotides or anti-TGF-beta serum, we have compared the proliferative capacities and the abilities of the CD34+ CD38- cell populations from bone marrow and umbilical cord blood to generate early progenitors in long-term cultures. The CD34+ CD38- fraction of umbilical cord blood accounts for 4% of the CD34+ fraction compared to only 1% in bone marrow, indicating that umbilical cord blood may be relatively enriched in stem cells. We estimate that the CD34+ CD38- cells from a typical umbilical cord blood sample produce equivalent numbers of colony-forming units (CFU)-granulocyte/erythrocyte/macrophage/megakaryocyte, twice as many CFU-granulocyte/macrophage (GM) and 3 times as many burst-forming units-erythroid as the same population from an average bone marrow sample used in adult transplantation. In addition, the colonies resulting from the umbilical cord blood samples were significantly larger than those from bone marrow, indicating a greater growth potential. However, the content of later progenitors, which may be important for short-term reconstitution, was less in umbilical cord blood-derived than in bone marrow-derived cell preparations, as estimated by a 4-fold lower production of CFU-GM in long-term cultures of CD34+ CD38+ cells. This deficit is partially compensated by the higher growth capacity of the resulting CFU-GM. These studies suggest that umbilical cord blood is a suitable source of cells for adult transplantation. PMID:7690969

  19. Intrauterine growth restriction is associated with structural alterations in human umbilical cord and decreased nitric oxide-induced relaxation of umbilical vein.

    PubMed

    Peyter, A-C; Delhaes, F; Baud, D; Vial, Y; Diaceri, G; Menétrey, S; Hohlfeld, P; Tolsa, J-F

    2014-11-01

    Intrauterine growth restriction (IUGR) affects ∼8% of all pregnancies and is associated with major perinatal mortality and morbidity, and with an increased risk to develop cardiovascular diseases in adulthood. Despite identification of several risk factors, the mechanisms implicated in the development of IUGR remain poorly understood. In case of placental insufficiency, reduced delivery of oxygen and/or nutrients to the fetus could be associated with alterations in the umbilical circulation, contributing further to the impairment of maternal-fetal exchanges. We compared the structural and functional properties of umbilical cords from growth-restricted and appropriate for gestational age (AGA) term newborns, with particular attention to the umbilical vein (UV). Human umbilical cords were collected at delivery. Morphological changes were investigated by histomorphometry, and UV's reactivity by pharmacological studies. Growth-restricted newborns displayed significantly lower growth parameters, placental weight and umbilical cord diameter than AGA controls. Total cross-section and smooth muscle areas were significantly smaller in UV of growth-restricted neonates than in controls. Maximal vasoconstriction achieved in isolated UV was lower in growth-restricted boys than in controls, whereas nitric oxide-induced relaxation was significantly reduced in UV of growth-restricted girls compared to controls. IUGR is associated with structural alterations of the UV in both genders, and with a decreased nitric oxide-induced relaxation in UV of newborn girls, whereas boys display impaired vasoconstriction. Further investigations will allow to better understand the regulation of umbilical circulation in growth-restricted neonates, which could contribute to devise potential novel therapeutic strategies to prevent or limit the development of IUGR. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Transplacental Distribution of Lidocaine and Its Metabolite in Peridural Anesthesia Administered to Patients With Gestational Diabetes Mellitus

    PubMed Central

    Duarte, Luciana de Barros; Cavalli, Ricardo de Carvalho; Carvalho, Daniela Miarelli; Filgueira, Gabriela Campos de Oliveira; Marques, Maria Paula; Lanchote, Vera Lucia; Duarte, Geraldo

    2015-01-01

    Background: Neonatal effects of drugs administered to mothers before delivery depend on the quantity that crosses the placental barrier, which is determined by the pharmacokinetics of the drug in the mother, fetus, and placenta. Diabetes mellitus can alter the kinetic disposition and the metabolism of drugs. This study investigated the placental transfer of lidocaine and its metabolite monoethylglycinexylidide (MEGX) in pregnant women with gestational diabetes mellitus (GDM) submitted to peridural anesthesia. Patients and Methods: A total of 10 normal pregnant women (group 1) and 6 pregnant women with GDM (group 2) were studied, all at term. The patients received 200 mg 2% lidocaine hydrochloride by the peridural locoregional route. Maternal blood samples were collected at the time of delivery and, after placental expulsion, blood samples were collected from the intervillous space, umbilical artery, and vein for determination of lidocaine and MEGX concentrations and analysis of the placental transfer of the drug. Results: The following respective lidocaine ratios between the maternal and the fetal compartments were obtained for groups 1 and 2: umbilical vein/maternal peripheral blood, 0.60 and 0.46; intervillous space/maternal blood, 1.01 and 0.88; umbilical artery/umbilical vein, 0.77 and 0.91; and umbilical vein/intervillous space, 0.53 and 0.51. The following MEGX ratios for groups 1 and 2 were, respectively, fetal/maternal, 0.43 and 0.97; intervillous space/maternal blood, 0.64 and 0.90; umbilical artery/umbilical vein, 1.09 and 0.99; and umbilical vein/intervillous space, 0.55 and 0.78. Conclusion: Gestational diabetes mellitus did not affect the transplacental transfer of lidocaine but interfered with the transfer of MEGX, acting as a mechanism facilitating the transport of the metabolite. PMID:25563756

  1. Transplacental Distribution of Lidocaine and Its Metabolite in Peridural Anesthesia Administered to Patients With Gestational Diabetes Mellitus.

    PubMed

    Moises, Elaine Christine Dantas; Duarte, Luciana de Barros; Cavalli, Ricardo de Carvalho; Carvalho, Daniela Miarelli; Filgueira, Gabriela Campos de Oliveira; Marques, Maria Paula; Lanchote, Vera Lucia; Duarte, Geraldo

    2015-07-01

    Neonatal effects of drugs administered to mothers before delivery depend on the quantity that crosses the placental barrier, which is determined by the pharmacokinetics of the drug in the mother, fetus, and placenta. Diabetes mellitus can alter the kinetic disposition and the metabolism of drugs. This study investigated the placental transfer of lidocaine and its metabolite monoethylglycinexylidide (MEGX) in pregnant women with gestational diabetes mellitus (GDM) submitted to peridural anesthesia. A total of 10 normal pregnant women (group 1) and 6 pregnant women with GDM (group 2) were studied, all at term. The patients received 200 mg 2% lidocaine hydrochloride by the peridural locoregional route. Maternal blood samples were collected at the time of delivery and, after placental expulsion, blood samples were collected from the intervillous space, umbilical artery, and vein for determination of lidocaine and MEGX concentrations and analysis of the placental transfer of the drug. The following respective lidocaine ratios between the maternal and the fetal compartments were obtained for groups 1 and 2: umbilical vein/maternal peripheral blood, 0.60 and 0.46; intervillous space/maternal blood, 1.01 and 0.88; umbilical artery/umbilical vein, 0.77 and 0.91; and umbilical vein/intervillous space, 0.53 and 0.51. The following MEGX ratios for groups 1 and 2 were, respectively, fetal/maternal, 0.43 and 0.97; intervillous space/maternal blood, 0.64 and 0.90; umbilical artery/umbilical vein, 1.09 and 0.99; and umbilical vein/intervillous space, 0.55 and 0.78. Gestational diabetes mellitus did not affect the transplacental transfer of lidocaine but interfered with the transfer of MEGX, acting as a mechanism facilitating the transport of the metabolite. © The Author(s) 2015.

  2. Comparison of umbilical cord ghrelin concentrations in full-term pregnant women with or without gestational diabetes.

    PubMed

    Karakulak, Murat; Saygili, Uğur; Temur, Muzaffer; Yilmaz, Özgür; Özün Özbay, Pelin; Calan, Mehmet; Coşar, Hese

    2017-05-01

    Ghrelin is a potent orexigenic peptide hormone secreted from the gastrointestinal tract that plays a crucial role in the regulation of lipids and glucose metabolism. Ghrelin also has links with fetal development and growth. Gestational diabetes mellitus (GDM) causes fetal macrosomia, but there is no available evidence of a relationship between ghrelin levels and birth weight in women with GDM. The purpose of this study is to investigate whether umbilical cord ghrelin concentrations are altered in full-term pregnant women with GDM compared to women without GDM and whether birth weight is correlated with ghrelin levels. Sixty pregnant women with GDM and 64 healthy pregnant women without GDM were included in this cross-sectional study. Blood samples were drawn from the umbilical vein following birth. Ghrelin concentrations were measured using enzyme-linked immunosorbent assay (ELISA). Umbilical vein ghrelin levels were decreased in women with GDM (879.6 ± 256.1 vs. 972.2 ± 233.6 pg/ml in women without GDM, p=0.033), whereas birth weights were higher for babies in the GDM than in the non-GDM group (3448 ± 410 vs. 3308 ± 365 gr, respectively, p=0.046). Umbilical ghrelin levels were inversely correlated with birth weight (r=-0.765, p<0.001). Multiple regression analysis revealed that birth weight was independently and negatively associated with umbilical ghrelin levels (β= -2.077, 95% CI=-2.652 to -1.492, p=0.002). Umbilical ghrelin levels were lower in GDM women. Birth weight was inversely associated with umbilical ghrelin levels. This association may be explained by a negative feedback mechanism between ghrelin and birth weight.

  3. Evaluating a switch from meconium to umbilical cord tissue for newborn drug testing: A retrospective study at an academic medical center.

    PubMed

    Palmer, Kendra L; Wood, Kelly E; Krasowski, Matthew D

    2017-04-01

    The objective of this study was to compare detection rates of newborn drug exposure at an academic medical center transitioning from meconium to umbilical cord tissue toxicology testing. We performed an Institutional Review Board-approved retrospective chart review on all newborns (n=2072) for whom newborn drug testing was ordered at our academic medical center between June 2012 and August 2015 (in August 2013, umbilical cord tissue became the preferred specimen). Meconium toxicology testing was positive for at least one compound in 221 cases (21.3% of 1037 total specimens), with non-medical drug use identified in 85 cases (8.2%). Umbilical cord tissue toxicology testing was positive for at least one compound in 302 cases (29.2%), with non-medical drug use identified in 107 cases (10.3%). Of the cases involving non-medical drug use, the most common compounds detected were tetrahydrocannabinol and amphetamines. Non-medical drug use did not differ significantly between meconium and umbilical cord tissue, either as a total or for classes of drugs such as amphetamines, cannabinoids, and opiates. Maternal non-medical use of tramadol (not tested for in meconium) was identified in 5 cases (0.4%). There were significant differences in rate of detection of iatrogenic medications. Specifically, morphine, lorazepam, phenobarbital, and codeine were more commonly detected in meconium, while oxycodone was more commonly detected in umbilical cord tissue. Umbilical cord tissue toxicology testing yielded a similar detection rate compared to meconium testing. The use of umbilical cord tissue avoids detection of medications given to the neonate prior to meconium collection. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  4. Genome-wide association study reveals a QTL and strong candidate genes for umbilical hernia in pigs on SSC14.

    PubMed

    Grindflek, Eli; Hansen, Marianne H S; Lien, Sigbjørn; van Son, Maren

    2018-05-29

    Umbilical hernia is one of the most prevalent congenital defect in pigs, causing economic losses and substantial animal welfare problems. Identification and implementation of genomic regions controlling umbilical hernia in breeding is of great interest to reduce incidences of hernia in commercial pig production. The aim of this study was to identify such regions and possibly identify causative variation affecting umbilical hernia in pigs. A case/control material consisting of 739 Norwegian Landrace pigs was collected and applied in a GWAS study with a genome-wide distributed panel of 60 K SNPs. Additionally candidate genes were sequenced to detect additional polymorphisms that were used for single SNP and haplotype association analyses in 453 of the pigs. The GWAS in this report detected a highly significant region affecting umbilical hernia around 50 Mb on SSC14 (P < 0.0001) explaining up to 8.6% of the phenotypic variance of the trait. The region is rather broad and includes 62 significant SNPs in high linkage disequilibrium with each other. Targeted sequencing of candidate genes within the region revealed polymorphisms within the Leukemia inhibitory factor (LIF) and Oncostatin M (OSM) that were significantly associated with umbilical hernia (P < 0.001). A highly significant QTL for umbilical hernia in Norwegian Landrace pigs was detected around 50 Mb on SSC14. Resequencing of candidate genes within the region revealed SNPs within LIF and OSM highly associated with the trait. However, because of extended LD within the region, studies in other populations and functional studies are needed to determine whether these variants are causal or not. Still without this knowledge, SNPs within the region can be used as genetic markers to reduce incidences of umbilical hernia in Norwegian Landrace pigs.

  5. Ultrasound-guided rectus sheath block in children with umbilical hernia: Case series.

    PubMed

    Alsaeed, Abdul Hamid; Thallaj, Ahmed; Khalil, Nancy; Almutaq, Nada; Aljazaeri, Ayman

    2013-10-01

    Umbilical hernia repair, a common day-case surgery procedure in children, is associated with a significant postoperative pain. The most popular peripheral nerve blocks used in umbilical hernia repair are rectus sheath infiltration and caudal block. The rectus sheath block may offer improved pain relief following umbilical hernia repair with no undesired effects such as lower limb motor weakness or urinary retention seen with caudal block which might delay discharge from the hospital. Ultrasound guidance of peripheral nerve blocks has reduced the number of complications and improved the quality of blocks. The aim of this case series is to assess the post rectus sheath block pain relief in pediatric patients coming for umbilical surgery. Twenty two (22) children (age range: 1.5-8 years) scheduled for umbilical hernia repair were included in the study. Following the induction of general anesthesia, the ultrasonographic anatomy of the umbilical region was studied with a 5-16 MHz 50 mm linear probe. An ultrasound-guided posterior rectus sheath block of both rectus abdominis muscles (RMs) was performed (total of 44 punctures). An in-plain technique using Stimuplex A insulated facet tip needle 22G 50mm. Surgical conditions, intraoperative hemodynamic parameters, and postoperative analgesia by means of the modified CHEOPS scale were evaluated. ultrasonograghic visualization of the posterior sheath was possible in all patients. The ultrasound guided rectus sheath blockade provided sufficient analgesia in all children with no need for additional analgesia except for one patient who postoperatively required morphine 0.1 mg/kg intravenously. There were no complications. Ultrasound guidance enables performances of an effective rectus sheath block for umbilical hernia. Use of the Stimuplex A insulated facet tip needle 22G 50mm provides easy, less traumatic skin and rectus muscle penetration and satisfactory needle visualiza.

  6. Vitellointestinal Duct Anomalies in Infancy

    PubMed Central

    Kadian, Yogender Singh; Verma, Anjali; Rattan, Kamal Nain; Kajal, Pardeep

    2016-01-01

    Background: Vitellointestinal duct (VID) or omphalomesenteric duct anomalies are secondary to the persistence of the embryonic vitelline duct, which normally obliterates by weeks 5–9 of intrauterine life. Methods: This is a retrospective analysis of a total of 16 patients of symptomatic remnants of vitellointestinal duct from period of Jan 2009 to May 2013. Results: Male to female ratio (M:F) was 4.3:1 and mean age of presentation was 2 months and their mode of presentation was: patent VID in 9 (56.25%) patients, umbilical cyst in 2(12.25%), umbilical granuloma in 2 (12.25%), and Meckel diverticulum as content of hernia sac in obstructed umbilical hernia in 1 (6.25%) patient. Two patients with umbilical fistula had severe electrolyte disturbance and died without surgical intervention. Conclusion: Persistent VID may have varied presentations in infancy. High output umbilical fistula and excessive bowel prolapse demand urgent surgical intervention to avoid morbidity and mortality. PMID:27433448

  7. Vitellointestinal Duct Anomalies in Infancy.

    PubMed

    Kadian, Yogender Singh; Verma, Anjali; Rattan, Kamal Nain; Kajal, Pardeep

    2016-01-01

    Vitellointestinal duct (VID) or omphalomesenteric duct anomalies are secondary to the persistence of the embryonic vitelline duct, which normally obliterates by weeks 5-9 of intrauterine life. This is a retrospective analysis of a total of 16 patients of symptomatic remnants of vitellointestinal duct from period of Jan 2009 to May 2013. Male to female ratio (M:F) was 4.3:1 and mean age of presentation was 2 months and their mode of presentation was: patent VID in 9 (56.25%) patients, umbilical cyst in 2(12.25%), umbilical granuloma in 2 (12.25%), and Meckel diverticulum as content of hernia sac in obstructed umbilical hernia in 1 (6.25%) patient. Two patients with umbilical fistula had severe electrolyte disturbance and died without surgical intervention. Persistent VID may have varied presentations in infancy. High output umbilical fistula and excessive bowel prolapse demand urgent surgical intervention to avoid morbidity and mortality.

  8. Active Vibration Isolation of Microgravity Experiments with Spring Umbilicals Using an Electrodynamic Actuator

    NASA Technical Reports Server (NTRS)

    Banerjee, B. B.; Allaire, P. E.; Grodsinsky, C. M.

    1996-01-01

    Microgravity experiments will require active vibration isolation in the low to mid frequency range of 0.1 Hz to 10 Hz. Approximately two orders of acceleration reduction (40 dB) will be required. Previous works have reported results for accelerations transmitted through the umbilical. This paper describes experimental and theoretical results for vibration isolation in one dimension (horizontal) where the simulated experiment is connected to the spacecraft by a spring umbilical. The experiment consisted of a spacecraft (shaker), experiment (mass), umbilical, accelerometer, control electronics, and Lorentz actuator. The experiment mass was supported in magnetic bearings to avoid any stiction problems. Acceleration feedback control was employed to obtain the vibration isolation. Three different spring umbilicals were employed. Acceleration reductions on the order of 40 dB were obtained over the frequency range of 0.1 Hz to 10 Hz. Good agreement was obtained between theory and experiment.

  9. [Persistent neonatal hypoglycaemia caused by arterial positioning of the umbilical venous catheter].

    PubMed

    Peters, P A G; Brus, F; Noordam, C; Smorenburg, M K; van Setten, P A

    2007-10-06

    Two neonates, a girl born at 40 2/7 weeks weighing 4165 g and a boy born at 37 6/7 weeks weighing 4040 g, received umbilical venous catheters to help manage hypoglycaemia. The catheter was ineffective or only effective when high doses of glucose were used, due to what later appeared to be arterial positioning of the catheter. Both patients recovered without consequences. Persistent hypoglycaemia is a common problem in newborns and can cause severe neurological sequelae. A relatively uncommon cause is malpositioning of the umbilical catheter. Positioning in an artery leads to direct infusion of glucose into the pancreas, which causes hyperinsulinaemia and can lead to potentially dangerous nonketotic hypoglycaemia. Arterial positioning of the umbilical catheter should be ruled out at an early stage. Correct catheter positioning can be determined using careful inspection of the umbilical veins, radiological examination of the catheter position, blood gas analysis or vascular pulsation.

  10. Core Stage Forward Skirt Umbilical Installation onto Mobile Laun

    NASA Image and Video Library

    2017-05-25

    A crane has been attached to the Core Stage Forward Skirt Umbilical (CSFSU) to lift it up for installation on the mobile launcher tower at NASA's Kennedy Space Center in Florida. The mobile launcher tower will be equipped with a number of lines, called umbilicals that will connect to the Space Launch System (SLS) rocket and Orion spacecraft for Exploration Mission-1 (EM-1). The CSFSU will be located at about the 180-foot level on the tower, above the liquid oxygen tank. The CSFSU is an umbilical that will swing into position to provide connections to the core stage forward skirt of the SLS rocket, and then swing away before launch. Its main purpose is to provide conditioned air/GN2 to the SLS core stage forward skirt cavity. The Ground Systems Development and Operations Program is overseeing installation of the umbilicals.

  11. Core Stage Forward Skirt Umbilical Installation onto Mobile Laun

    NASA Image and Video Library

    2017-05-25

    Cranes and rigging are being used to lift the Core Stage Forward Skirt Umbilical (CSFSU) into position for installation on the mobile launcher tower at NASA's Kennedy Space Center in Florida. The mobile launcher tower will be equipped with a number of lines, called umbilicals that will connect to the Space Launch System (SLS) rocket and Orion spacecraft for Exploration Mission-1 (EM-1). The CSFSU will be located at about the 180-foot level on the tower, above the liquid oxygen tank. The CSFSU is an umbilical that will swing into position to provide connections to the core stage forward skirt of the SLS rocket, and then swing away before launch. Its main purpose is to provide conditioned air/GN2 to the SLS core stage forward skirt cavity. The Ground Systems Development and Operations Program is overseeing installation of the umbilicals.

  12. Core Stage Forward Skirt Umbilical Installation onto Mobile Laun

    NASA Image and Video Library

    2017-05-25

    Seeming to hang in midair, the Core Stage Forward Skirt Umbilical (CSFSU) is lifted high up by crane for installation on the mobile launcher tower at NASA's Kennedy Space Center in Florida. The mobile launcher tower will be equipped with a number of lines, called umbilicals that will connect to the Space Launch System rocket and Orion spacecraft for Exploration Mission-1 (EM-1). The CSFSU will be located at about the 180-foot level on the tower, above the liquid oxygen tank. The CSFSU is an umbilical that will swing into position to provide connections to the core stage forward skirt of the SLS rocket, and then swing away before launch. Its main purpose is to provide conditioned air/GN2 to the SLS core stage forward skirt cavity. The Ground Systems Development and Operations Program is overseeing installation of the umbilicals.

  13. Rotatable electric cable connecting system

    NASA Technical Reports Server (NTRS)

    Manges, D. R. (Inventor)

    1985-01-01

    A cable reel assembly is described which is particularly adapted for, but not limited to, a system for providing electrical connection of power and data signals between an orbiter vehicle, such as a space shuttle, and a recovered satellite. The assembly is comprised of two mutually opposing ring type structures having 180 deg relative rotation with one of the structures being held in fixed position while the other structure is rotatable. Motor controlled berthing latches and umbilical cable connectors for the satellite are located on the rim of the rotatable ring structure. The electrical cable assembly is fed in two sections from the orbiter vehicle into the outer rim portion of the fixed ring structure where they are directed inwardly and attached to two concentrically coiled metal bands whose respective ends are secured to inner and outer post members of circular sets of guide pins located on opposing circular plate members, one rotatable and one fixed. The cable sections are fed out as three output cable sections through openings in the central portion of the circular plate of the rotatable ring structure where they are directed to the latches and connectors located on its rim.

  14. Eviscerated urinary bladder via ruptured umbilical hernia: a rare occurrence.

    PubMed

    Pandey, A; Kumar, V; Gangopadhyay, A N; Upadhyaya, V D

    2008-06-01

    Umbilical hernia is a common problem encountered in children. Rupture and evisceration are very rare phenomena, and the usual content that is eviscerated is the bowel. We present an infant who had a ruptured umbilical hernia with eviscerated urinary bladder dome. As this is the first case of its kind, it is being reported with a brief review of literature.

  15. Persistent Umbilical Discharge from an Omphalomesenteric Duct Cyst Containing Gastric Mucosa

    PubMed Central

    Tamilselvan, Kanimozhi; Mohan, Arunodaya; Cheslyn-Curtis, Sarah; Eisenhut, Michael

    2012-01-01

    Umbilical discharge in infancy is often attributed to infection or an umbilical granuloma. It is important to investigate if such a discharge is due to an underlying congenital abnormality because corrective surgical intervention may then be required. We present the first case of an infant with a persistent umbilical discharge from an omphalomesenteric duct cyst. The discharge was associated with periumbilical dermatitis. The dermatitis was most likely due to irritation of the skin by gastric acid produced by the ectopic gastric mucosa contained in the omphalomesenteric duct cyst. Both discharge and dermatitis resolved after surgical removal of the cyst. PMID:22693676

  16. A "Kane's Dynamics" Model for the Active Rack Isolation System

    NASA Astrophysics Data System (ADS)

    Rupert, J. K.; Hampton, R. D.; Beech, G. S.

    2005-02-01

    In the late 1980s, microgravity researchers began to voice their concern that umbilical-transmitted energy could significantly degrade the acceleration environment of microgravity space science experiments onboard manned spacecraft. Since umbilicals are necessary for many experiments, control designers began to seek ways to compensate for these "indirect" disturbances. Hampton, et al., used the Kane s method to develop a model of the active rack isolation system (ARIS) that includes (1) actuator control forces, (2) direct disturbance forces, and (3) indirect, actuator-transmitted disturbances. Their model does not, however, include the indirect, umbilical-transmitted disturbances. Since the umbilical stiffnesses are not negligible, these indirect disturbances must be included in the model. Until the umbilicals have been appropriately included, the model will be incomplete. This Technical Memorandum presents a nonlinear model of ARIS with umbilicals included. Model verification was achieved by utilizing two commercial-off-the-shelf software tools. Various forces and moments were applied to the model to yield simulated responses of the system. Plots of the simulation results show how various critical points on an ARIS-outfitted international standard payload rack behave under the application of direct disturbances, indirect disturbances, and control forces. Simulations also show system response to a variety of initial conditions.

  17. Design of the Core Stage Inter-Tank Umbilical {CSITU) Compliance Mechanism

    NASA Technical Reports Server (NTRS)

    Smith, Kurt R.

    2013-01-01

    Project Goals: a) Design the compliance mechanism for the CSITU system to a 30% level -3D models completed in Pro/Engineer -Relevant design analysis b) Must meet all system requirements and establish basis for proceeding with detailed design. Tasks to be completed: A design that meets requirements for the 30% design review, 01/16/2013. Umbilical arms provide commodities to the launch vehicle prior to T-0. Commodities can range anywhere from hydraulics, pneumatics, cryogenic, electrical, ECS, etc ... Umbilicals commonly employ truss structures to deliver commodities to vehicle. Common configurations include: -Tilt-up -Swing Arm -Hose Drape -Drop Arm Umbilical arms will be mounted to Mobile Launch Platform. SLS currently has 9 T-0 umbilical arms. The compliance refers to the ability of the umbilical to adjust to minor changes in vehicle location. The compliance mechanism refers to the mechanism on the ground support equipment {GSE) that compensates for these changes. For the CSITU, these minor changes, or vehicle excursions, can be up to +4 in. Excursions refer to movements of the vehicle caused by wind loads and thermal expansion. It is ideal to have significant vertical compliance so a passive secondary release mechanism may be implemented.

  18. Umbilical hernia rupture with evisceration of omentum from massive ascites: a case report

    PubMed Central

    2011-01-01

    Introduction The incidence of hernias is increased in patients with alcoholic liver disease with ascites. To the best of our knowledge, this is the first report of an acute rise in intra-abdominal pressure from straining for stool as the cause of a ruptured umbilical hernia. Case presentation An 81-year-old Caucasian man with a history of alcoholic liver disease presented to our emergency department with an erythematous umbilical hernia and clear, yellow discharge from the umbilicus. On straining for stool, after initial clinical assessment, our patient noted a gush of fluid and evisceration of omentum from the umbilical hernia. An urgent laparotomy was performed with excision of the umbilicus and devitalized omentum. Conclusion We report the case of a patient with a history of alcoholic liver disease with ascites. Ascites causes a chronic increase in intra-abdominal pressure. A sudden increase in intra-abdominal pressure, such as coughing, vomiting, gastroscopy or, as in this case, straining for stool can cause rupture of an umbilical hernia. The presence of discoloration, ulceration or a rapid increase in size of the umbilical hernia signals impending rupture and should prompt the physician to reduce the intra-abdominal pressure. PMID:21539740

  19. The Perfect Mate for Safe Fueling

    NASA Technical Reports Server (NTRS)

    2004-01-01

    Referred to as the "lifeline for any space launch vehicle" by NASA Space Launch Initiative Program Manager Warren Wiley, an umbilical is a large device that transports power, communications, instrument readings, and fluids such as propellants, pressurization gases, and coolants from one source to another. Numerous launch vehicles, planetary systems, and rovers require umbilical "mating". This process is a driving factor for dependable and affordable space access. With future-generation space vehicles in mind, NASA recently designed a smart, automated method for quickly and reliably mating and demating electrical and fluid umbilical connectors. The new umbilical concept is expected to replace NASA s traditional umbilical systems that release at vehicle lift-off (T-0). The idea is to increase safety by automatically performing hazardous tasks, thus reducing potential failure modes and the time and labor hours necessary to prepare for launch. The new system will also be used as a test bed for quick disconnect development and for advance control and leak detection. It incorporates concepts such as a secondary mate plate, robotic machine vision, and compliant motor motion control, and is destined to advance usage of automated umbilicals in a variety of aerospace and commercial applications.

  20. Cryopreserved, Xeno-Free Human Umbilical Cord Mesenchymal Stromal Cells Reduce Lung Injury Severity and Bacterial Burden in Rodent Escherichia coli-Induced Acute Respiratory Distress Syndrome.

    PubMed

    Curley, Gerard F; Jerkic, Mirjana; Dixon, Steve; Hogan, Grace; Masterson, Claire; O'Toole, Daniel; Devaney, James; Laffey, John G

    2017-02-01

    Although mesenchymal stem/stromal cells represent a promising therapeutic strategy for acute respiratory distress syndrome, clinical translation faces challenges, including scarcity of bone marrow donors, and reliance on bovine serum during mesenchymal stem/stromal cell proliferation. We wished to compare mesenchymal stem/stromal cells from human umbilical cord, grown in xeno-free conditions, with mesenchymal stem/stromal cells from human bone marrow, in a rat model of Escherichia coli pneumonia. In addition, we wished to determine the potential for umbilical cord-mesenchymal stem/stromal cells to reduce E. coli-induced oxidant injury. Randomized animal study. University research laboratory. Male Sprague-Dawley rats. Acute respiratory distress syndrome was induced in rats by intratracheal instillation of E. coli (1.5-2 × 10 CFU/kg). "Series 1" compared the effects of freshly thawed cryopreserved umbilical cord-mesenchymal stem/stromal cells with bone marrow-mesenchymal stem/stromal cells on physiologic indices of lung injury, cellular infiltration, and E. coli colony counts in bronchoalveolar lavage. "Series 2" examined the effects of cryopreserved umbilical cord-mesenchymal stem/stromal cells on survival, as well as measures of injury, inflammation and oxidant stress, including production of reactive oxidative species, reactive oxidative species scavenging by superoxide dismutase-1 and superoxide dismutase-2. In "Series 1," animals subjected to E. coli pneumonia who received umbilical cord-mesenchymal stem/stromal cells had improvements in oxygenation, respiratory static compliance, and wet-to-dry ratios comparable to bone marrow-mesenchymal stem/stromal cell treatment. E. coli colony-forming units in bronchoalveolar lavage were reduced in both cell therapy groups, despite a reduction in bronchoalveolar lavage neutrophils. In series 2, umbilical cord-mesenchymal stem/stromal cells enhanced animal survival and decreased alveolar protein and proinflammatory cytokine concentrations, whereas increasing interleukin-10 concentrations. Umbilical cord-mesenchymal stem/stromal cell therapy decreased nicotinamide adenine dinucleotide phosphate-oxidase 2 and inducible nitric oxide synthase and enhanced lung concentrations of superoxide dismutase-2, thereby reducing lung tissue reactive oxidative species concentrations. Our results demonstrate that freshly thawed cryopreserved xeno-free human umbilical cord-mesenchymal stem/stromal cells reduce the severity of rodent E. coli-induced acute respiratory distress syndrome. Umbilical cord-mesenchymal stem/stromal cells, therefore, represent an attractive option for future clinical trials in acute respiratory distress syndrome.

  1. Torsion fracture of carbon nanocoils

    NASA Astrophysics Data System (ADS)

    Yonemura, Taiichiro; Suda, Yoshiyuki; Tanoue, Hideto; Takikawa, Hirofumi; Ue, Hitoshi; Shimizu, Kazuki; Umeda, Yoshito

    2012-10-01

    We fix a carbon nanocoil (CNC) on a substrate in a focused ion beam instrument and then fracture the CNC with a tensile load. Using the CNC spring index, we estimate the maximum to average stress ratio on the fractured surface to range from 1.3 to 1.7, indicating stress concentration on the coil wire inner edge. Scanning electron microscopy confirms a hollow region on the inner edge of all fractured surfaces.

  2. Clinical accuracy of non-contact infrared thermometer from umbilical region in children: A new side.

    PubMed

    Apa, Hurşit; Gözmen, Salih; Keskin-Gözmen, Şükran; Aslan, Fatma; Bayram, Nuri; Devrim, İlker

    2016-01-01

    Measurement from axillary site with digital thermometer has been accepted as the most accurate method. But this method is time consuming. Tympanic and forehead measurements are often used but don't always seem to be more appropriate. Another site, umbilical region, could be an alternative site. This study aims to compare the measurements with axillary digital thermometer and non-contact infrared thermometers at sites from umbilicus and forehead to determine whether umbilical site could be used accurately in children. For each method, 2,048 measurements in total were performed. Using axillary method as gold standard, with a cut-off temperature of 38oC, the sensitivities and specificities, positive and negative predictive values of umbilical and forehead temperatures and area under the ROC curve were determined in non obese children. There was a significant positive correlation between axillary and umbilical temperatures with a correlation coefficient of 0.78. The average difference between the mean of both axillary and umbilical temperatures was -0.47 ± 0.65°C. The Bland-Altman plot showed good accuracy with only 2.5 % of the readings falling outside the 95% level of confidence. Umbilical measurements showed sensitivity of 71.7% and specificity of 95.8%. The area under the ROC curve was 0.93. The easy application may lead noncontact measurements from umbilicus site to be the preferable method for health care providers, but agreement limits mentioned in this study should be considered.

  3. [Umbilical blood-gas status at cesarean section for breech presentation: a comparison with vertex presentation].

    PubMed

    Haruta, M; Saeki, N; Naka, Y; Funato, T; Ohtsuki, Y

    1989-10-01

    Umbilical blood-gas status at elective cesarean section with oxygen inhalation for breech presentation (25 cases) was compared with that for vertex presentation (25 cases), so as to confirm the security of full-term breech fetuses delivered by cesarean section under spinal anesthesia. Umbilical arterial oxygen levels were significantly lower in the breech group (Mean PO2:18.9 mmHg; SO2:37.3%; Oxygen content:7.6 ml/dl). The number of hypoxemic fetuses was significantly higher in the breech group (the breech: 7; the vertex; 0). The other umbilical blood-gas values revealed no significant differences between the breech and vertex groups, and were within normal limits in both groups. Oxygen extraction in the breech (Mean: 49.0%) was higher than that in the vertex (32.9%). Therefore decreased umbilical blood flow in the breech was suggested. The incidence of depression at 1 minute after delivery in the breech infants (24%) was significantly higher than that in the vertex infants (0%). It became obvious in the breech that as the interval between the uterine incision and delivery increased, umbilical arterial blood tended to acidosis and the 1 minute Apgar score decreased. Cesarean section for breech presentation requires sufficient and optimal incisions of the abdominal wall and uterus as well as a skillful manual delivery technique, because the fetus or neonate should be protected against asphyxia resulting from umbilical compression and prolonged delivery interval.

  4. Umbilical artery histomorphometry: a link between the intrauterine environment and kidney development.

    PubMed

    DeFreitas, M J; Mathur, D; Seeherunvong, W; Cano, T; Katsoufis, C P; Duara, S; Yasin, S; Zilleruelo, G; Rodriguez, M M; Abitbol, C L

    2017-06-01

    Prematurity is a risk factor for hypertension, vascular stiffness, nephron deficit and adult onset cardiorenal disease. The vascular tree and kidneys share morphogenic drivers that promote maturation in utero before 36 weeks of gestation. Vascular elastin accrual terminates after birth leaving collagen to promote vascular stiffness. Our objective was to determine if the histomorphometry of the umbilical artery, an extension of the aorta, parallels nephron mass across gestational age groups. From a cohort of 54 newborns, 32 umbilical cord specimens were adequate for evaluation. The umbilical cord was sectioned, stained with trichrome, and digitalized. Muscular and collagenous areas of the umbilical artery were measured in pixels using the Image J 1.48q software. Total kidney volume was measured by ultrasound and factored by body surface area (TKV/BSA). The umbilical artery total area was significantly greater in term v. preterm infants (9.3±1.3 v. 7.0±2.0 mm2; P<0.05) and increased with gestational age; while the percent muscular and collagen areas were independent of gestational age (R 2=0.04; P=ns). Percent muscular area correlated positively with TKV/BSA (r=0.53; P=0.002); while an increase in collagen correlated inversely with kidney mass (r=-0.53; P=0.002). In conclusion, an enhanced % muscular area and presumed vascular elasticity was associated with increased renal mass in all infants. Umbilical artery histomorphometry provides a link between the intrauterine environment, vascular and kidney development.

  5. 44. VIEW OF UMBILICAL MAST AND LAUNCH PAD FROM SOUTHWEST. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    44. VIEW OF UMBILICAL MAST AND LAUNCH PAD FROM SOUTHWEST. DOORS FOR THE UMBILICAL MAST TRENCH RAISED FOR MAINTENANCE POSITION OF 10 DEGREES. LAUNCHER IS RIGHT OF MAST; RAILS PARALLEL TO MAST. CONTROL PANELS LEFT TO RIGHT: ELECTRICAL PANEL, COMMUNICATIONS PANEL, AND MAST CONTROL PANEL. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 East, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  6. Systematic design of broadband path-coiling acoustic metamaterials

    NASA Astrophysics Data System (ADS)

    Jia, Zhetao; Li, Junfei; Shen, Chen; Xie, Yangbo; Cummer, Steven A.

    2018-01-01

    A design approach for acoustic metamaterial unit cells based on a coiled path with impedance matching layers (IMLs) is proposed in this paper. A theoretical approach is developed to calculate the transmission of the labyrinthine unit cells with different effective refractive indices. The IML is introduced to broaden the transmission bandwidth and produce a lower envelope boundary of transmission for unit cells of different effective refractive indices. According to the theory, cells of all effective refractive indices can be built to achieve unitary transmission at center working frequencies. The working frequency can be tuned by adjusting the length of the IML. Numerical simulations based on finite element analysis are used to validate the theoretical predictions. The high transmission and low dispersive index nature of our designs are further verified by experiments within a broad frequency band of over 1.4 kHz centered at 2.86 kHz. Our design approach can be useful in various wavefront engineering applications.

  7. Pseudoaneurysm of the Profunda Femoris Artery following Blunt Trauma Treated by Endovascular Coil Embolization: Review of Two Cases and Relevant Literature

    PubMed Central

    McNerney, Patrick; Kiproff, Paul

    2017-01-01

    Profunda femoris artery (PFA) pseudoaneurysm after blunt trauma without associated femur fracture is a rare occurrence. Most of the reported cases of PFA pseudoaneurysm in the English literature developed after penetrating trauma, surgical procedures, and femur fractures. We present two such cases following blunt trauma and without any associated long bone injury. After initial imaging failed to show any long bone fracture, CT angiography confirmed pseudoaneurysm of the branch of the PFA. Both patients were then treated with emergent coil embolization of the bleeding vessel. Pseudoaneurysms typically present late and signs of persistent hip pain, thigh swelling, presence of a pulsatile mass, and even unexplained anemia all may suggest the diagnosis. Recognition of PFA pseudoaneurysm requires high index of suspicion and is often difficult to diagnose clinically because of its location. PMID:28246563

  8. Study of the electromagnetic characteristics of multiple HTSPPT modules based on the configuration of toroidal structure for inductive pulsed power supply

    NASA Astrophysics Data System (ADS)

    Zhang, Cunshan; Zheng, Xinxin; Li, Haitao; Li, Zhenmei; Zhang, Tao; Jiao, Can

    2018-04-01

    High temperature superconducting pulsed power transformer (HTSPPT) is an important device for pulsed power supplies. It consists of a superconducting primary and a normal conducting secondary, which is used for energy storage and current amplification. The critical current density, the energy storage, and the coupling coefficient are three main performance indexes. They are affected by the geometry parameters of HTSPPT modules, such as the height and the width of the superconducting coils. In addition, the hoop stress of the HTSPPT coils is limited by the maximum tensile strength of high temperature superconducting (HTS) tapes. In this paper, Bi-2223/Ag HTS tapes are selected as the wire of primary inductor and the toroidal structure model is selected for multiple HTSPPT modules. The relationships between the geometry parameters of HTSPPT modules and the electrical performance are studied.

  9. Intrapartum amnioinfusion in women with oligohydramniosis. A prospective randomized trial.

    PubMed

    Persson-Kjerstadius, N; Forsgren, H; Westgren, M

    1999-02-01

    To evaluate the effects of amnioinfusion in oligohydramniosis. During a 20-month period, patients at term with oligohydramniosis (amniotic fluid index less than 5 cm) at Huddinge University and Norrköping Hospitals were recruited for a prospective randomized study to evaluate amnioinfusion. Informed consent was obtained from 112 patients who met the entry criteria. Sixty subjects were randomized to amnioinfusion and 52 to the control group. Outcome parameters included fetal heart rate abnormalities, mode of delivery, Apgar score, pH in umbilical artery blood and need for neonatal intensive care. The cesarean section rate was significantly reduced in the amnio-infusion group (29% versus 13%, p=0.043). No difference in time from randomization to delivery was detected between the two groups. The frequency of ominous fetal heart rate tracings with a cervical dilatation of 0-3 cm was the same in the two groups. The frequency of such heart rate patterns after amnioinfusion was significantly lower than in the control group. Neonatal outcome, pH in the umbilical artery blood and need for neonatal intensive care did not differ between the two groups. The present study confirms the findings of other authors that amnioinfusion effectively reduces the number of cesarean sections in cases of oligohydramniosis.

  10. [Effect of cryopreservation on umbilical blood cells and its mechanism].

    PubMed

    Li, Xin; Chen, Fangping; Jiang, Tiebin; Wang, Erhua; Liu, Jing

    2013-07-01

    To evaluate the effect of cryopreservation on clonogenic ability and apoptosis rate of mono-nuclear cells and CD34+ cells in umbilical blood (UB), and to choose the index to present the freezing injury and optimize the cryopreservation of UB. The mono-nuclear cells (MNC) and CD34+ cells were separated from UB and frozen.After 30 days, they were thawed in warm water. Clonogenic capacity and clonogenic recovery before and after the cryopreservation was compared. We also used Annexin V-FITC-PI to investigate the apoptosis rate of the cells before and after the cryopreservation of these 2 types of cells. The number of colony forming unit-granulocyte/monocyte (CFU-GMs) was not changed after freezing and thawing in both MNCs and CD34+ cells, while the number of colony forming unit-granulocyte, erythrocyte, monocyte and megakaryocyte (CFU-GEMM) was obviously reduced after freezing in CD34+ cells. The 2 types of cryopreserved cells had certain degree of apoptosis before the cryopreservation. MNC-type cryopreservation increased the cells apoptosis a little, while CD34+-type cryopreservation increased more. The cells have certain degree of apoptosis before the cryopreservation. The freezing and thawing procedure does affect the early stage progenitor cells-CFU-GEMM in the CD34+- type cryopreserved cells in UB. The damage may be induced by the cell apoptosis.

  11. Genome-Wide Identification of Arabidopsis Coiled-Coil Proteins and Establishment of the ARABI-COIL Database1

    PubMed Central

    Rose, Annkatrin; Manikantan, Sankaraganesh; Schraegle, Shannon J.; Maloy, Michael A.; Stahlberg, Eric A.; Meier, Iris

    2004-01-01

    Increasing evidence demonstrates the importance of long coiled-coil proteins for the spatial organization of cellular processes. Although several protein classes with long coiled-coil domains have been studied in animals and yeast, our knowledge about plant long coiled-coil proteins is very limited. The repeat nature of the coiled-coil sequence motif often prevents the simple identification of homologs of animal coiled-coil proteins by generic sequence similarity searches. As a consequence, counterparts of many animal proteins with long coiled-coil domains, like lamins, golgins, or microtubule organization center components, have not been identified yet in plants. Here, all Arabidopsis proteins predicted to contain long stretches of coiled-coil domains were identified by applying the algorithm MultiCoil to a genome-wide screen. A searchable protein database, ARABI-COIL (http://www.coiled-coil.org/arabidopsis), was established that integrates information on number, size, and position of predicted coiled-coil domains with subcellular localization signals, transmembrane domains, and available functional annotations. ARABI-COIL serves as a tool to sort and browse Arabidopsis long coiled-coil proteins to facilitate the identification and selection of candidate proteins of potential interest for specific research areas. Using the database, candidate proteins were identified for Arabidopsis membrane-bound, nuclear, and organellar long coiled-coil proteins. PMID:15020757

  12. Term Neonate with Atypical Hypoxic-Ischemic Encephalopathy Presentation: A Case Report

    PubMed Central

    Townley, Nick; McNellis, Emily; Sampath, Venkatesh

    2017-01-01

    We describe a case of atypical hypoxic-ischemic encephalopathy (HIE) in a neonate following a normal pregnancy and delivery who was found to have an umbilical vein thrombosis. The infant arrived to our center with continuous bicycling movement of her lower extremities. She had a continuous electroencephalogram that showed burst suppression and magnetic resonance imaging of the brain showed diffusely abnormal cerebral cortical/subcortical diffusion restriction which may be secondary hypoxic-ischemic injury. Interestingly, a pathology report noted a focal umbilical vein thrombosis appearing to have compressed an umbilical artery with associated arterial dissection and hematoma. Our case illustrates how umbilical venous or arterial thrombosis may be associated with HIE and refractory seizures. PMID:28852582

  13. Term Neonate with Atypical Hypoxic-Ischemic Encephalopathy Presentation: A Case Report.

    PubMed

    Townley, Nick; McNellis, Emily; Sampath, Venkatesh

    2017-07-01

    We describe a case of atypical hypoxic-ischemic encephalopathy (HIE) in a neonate following a normal pregnancy and delivery who was found to have an umbilical vein thrombosis. The infant arrived to our center with continuous bicycling movement of her lower extremities. She had a continuous electroencephalogram that showed burst suppression and magnetic resonance imaging of the brain showed diffusely abnormal cerebral cortical/subcortical diffusion restriction which may be secondary hypoxic-ischemic injury. Interestingly, a pathology report noted a focal umbilical vein thrombosis appearing to have compressed an umbilical artery with associated arterial dissection and hematoma. Our case illustrates how umbilical venous or arterial thrombosis may be associated with HIE and refractory seizures.

  14. Nurses' guide to early detection of umbilical arterial catheter complications in infants.

    PubMed

    Furdon, Susan Arana; Horgan, Michael J; Bradshaw, Wanda Todd; Clark, David A

    2006-10-01

    Umbilical arterial catheters (UAC) are routinely used in the care of critically ill newborns. Complications related to UACs include vascular compromise, hemorrhage, complications related to malposition, severance of the catheter itself, and infection. This article is Part II in a series dedicated to assessing infants with an umbilical catheter. Part I focused on infants with umbilical venous catheters; this article will focus on the physical assessment relevant to infants with an UAC. Complications related to UACs can occur during any phase of treatment: insertion, while indwelling, or after discontinuing the catheter. Review of clinical signs of complications along with clinical photographs, will assist caregivers in promptly recognizing UAC-related complications.

  15. [Hernia surgery in urology: part 1: inguinal, femoral and umbilical hernias - fundamentals of clinical diagnostics and treatment].

    PubMed

    Franz, T; Schwalenberg, T; Dietrich, A; Müller, J; Stolzenburg, J-U

    2013-05-01

    Hernias are a common occurrence with correspondingly huge clinical and economic impacts on the healthcare system. The most common forms of hernia which need to be diagnosed and treated in routine urological work are inguinal and umbilical hernias. With the objective of reconstructing and stabilizing the inguinal canal there are the possibilities of open and minimally invasive surgery and both methods can be performed with suture or mesh repair. Indications for surgery of umbilical hernias are infrequent although this is possible with little effort under local anesthesia. This article presents an overview of the epidemiology, pathogenesis, clinical symptoms, diagnostics and therapy of inguinal, femoral and umbilical hernias.

  16. Orion Service Module Umbilical (OSMU) Installation

    NASA Image and Video Library

    2017-03-16

    A crane lifts the Orion Service Module Umbilical (OSMU) high up for installation on the mobile launcher tower at NASA's Kennedy Space Center in Florida. The mobile launcher tower will be equipped with a number of lines, called umbilicals, that will connect to the Space Launch System rocket and Orion spacecraft for Exploration Mission-1 (EM-1). The OSMU will be located high on the mobile launcher tower and, prior to launch, will transfer liquid coolant for the electronics and air for the Environmental Control System to the Orion service module that houses these critical systems to support the spacecraft. EM-1 is scheduled to launch in 2018. The Ground Systems Development and Operations Program is overseeing installation of the umbilicals.

  17. Umbilical cord blood transplants: treatment for selected hematologic and oncologic diseases.

    PubMed

    Stevens, K

    1997-12-01

    Umbilical cord blood transplantation is a rapidly growing form of treatment for many types of cancer and hematologic disorders. The concepts behind the use of umbilical cord blood transplantation are based on information gained from experience in bone marrow transplantation. Previously discarded as human waste, the blood in the umbilical cord remnant and the placenta has been observed to be rich in hematopoietic stem cells. Techniques for collecting these stem cells from the placenta may vary among the institutions, physicians, and other health care providers, including midwives and nurse practitioners, involved with this procedure. This source of hematopoietic stem cells in transplantation has many advantages, disadvantages, and controversies associated with its use.

  18. Simultaneous Umbilical Hernia Repair with Transumbilical Ventriculoperitoneal Shunt Placement.

    PubMed

    Montalbano, Michael J; Loukas, Marios; Oakes, W Jerry; Tubbs, R Shane

    2017-01-01

    Recently, placement of a ventriculoperitoneal shunt via a transumbilical approach has been reported. Herein, we report the repair of an umbilical hernia via the same incision and introduction of the distal end of a ventricultoperitoneal shunt into the peritoneal cavity in 3 patients. A case illustration is included. Both hernia repair and placement of the distal end of the ventriculoperitoneal shunt were uncomplicated in our small case series. To our knowledge, simultaneous repair of an umbilical hernia followed by transumbilical shunt placement has not been reported. As umbilical hernias are so common in infants, this finding, based on our experience, should not exclude placement of peritoneal tubing in the same setting. © 2017 S. Karger AG, Basel.

  19. Long-term follow-up after transvenous single coil embolization of patent ductus arteriosus in dogs.

    PubMed

    Hildebrandt, N; Schneider, C; Schweigl, T; Schneider, M

    2010-01-01

    Long-term follow-up studies after interventional therapy of patent ductus arteriosus (PDA) in dogs are rare. Transvenous PDA embolization with a single detachable coil is a highly effective method in patients with an angiographically determined PDA≤4.0 mm. Twenty-eight dogs with an angiographic PDA≤4.0 mm were included. Prospective follow-up study after PDA coil embolization. The median follow-up time was 792 days (range, 2-3, 248 days). The rate of complete closure demonstrated by Doppler color flow was 54% at day 3 after intervention and the final cumulative rate was 71%. The rate of complete closure was significantly different between small and moderately sized PDA over the study period (P<.0001) and finally was 100 and 50%, respectively. In 16 dogs with complete closure, no recanalization was found. Disappearance of the continuous heart murmur was found in 89% after 3 days, and this increased to a final cumulative rate of 96%. Indexed left ventricular internal diameter in diastole (LVDd-I) decreased significantly (P<.0001). In the group with moderately sized PDA, a significant difference (P=.0256) was seen in LVDd-I between patients with and without residual shunt after exclusion of patients with persistent severe mitral valve regurgitation. Long-term follow-up after single coil embolization showed complete closure in all small PDA but a residual shunt with mild hemodynamic consequences was present in half of the moderately sized PDA. Copyright © 2010 by the American College of Veterinary Internal Medicine.

  20. T2- and diffusion-weighted magnetic resonance imaging at 3T for the detection of prostate cancer with and without endorectal coil: An intraindividual comparison of image quality and diagnostic performance.

    PubMed

    Baur, Alexander D J; Daqqaq, Tareef; Wagner, Moritz; Maxeiner, Andreas; Huppertz, Alexander; Renz, Diane; Hamm, Bernd; Fischer, Thomas; Durmus, Tahir

    2016-06-01

    To intraindividually compare image quality and diagnostic performance of multiparametric MRI (mpMRI) at 3T for the detection of prostate cancer (PCa) using a pelvic phased-array coil (PAC) and a combined endorectal and pelvic phased-array coil (ERC-PAC). Forty-five patients were prospectively included and received mpMRI of the prostate using a PAC and an ERC-PAC during one imaging session. Two radiologists evaluated image quality and the most suspicious lesion according to the PI-RADS scoring system. Results of MRI-TRUS-fusion biopsy of the prostate served as reference standard. Patient comfort and acceptance were assessed using a standardized questionnaire. Overall image quality for T2WI was rated significantly better with an ERC-PAC compared to a PAC (p=0.0038). The weighted kappa for PI-RADS scores for T2WI and DWI with a PAC and an ERC-PAC was 0.70 and 0.73, respectively. For a PI-RADS sum score including T2WI and DWI the area under the curve with a PAC and an ERC-PAC were 0.95-0.99 and 0.93-0.97, respectively (p=0.1395). For T2WI and DWI performed at 3T index PCa lesion identification and evaluation did not differ significantly with both coil setups. Patients preferred MRI without an ERC. Therefore, the use of an ERC may be omitted in a prostate cancer detection setting. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  1. Umbilical Connect Techniques Improvement-Technology Study

    NASA Technical Reports Server (NTRS)

    Valkema, Donald C.

    1972-01-01

    The objective of this study was to develop concepts, specifications, designs, techniques, and procedures capable of significantly reducing the time required to connect and verify umbilicals for ground services to the space shuttle. The desired goal was to reduce the current time requirement of several shifts for the Saturn 5/Apollo to an elapsed time of less than one hour to connect and verify all of the space shuttle ground service umbilicals. The study was conducted in four phases: (1) literature and hardware examination, (2) concept development, (3) concept evaluation and tradeoff analysis, and (4) selected concept design. The final product of this study was a detail design of a rise-off disconnect panel prototype test specimen for a LO2/LH2 booster (or an external oxygen/hydrogen tank for an orbiter), a detail design of a swing-arm mounted preflight umbilical carrier prototype test specimen, and a part 1 specification for the umbilical connect and verification design for the vehicles as defined in the space shuttle program.

  2. Umbilical Stiffness Matrix Characterization and Testing for Microgravity Science Payloads

    NASA Technical Reports Server (NTRS)

    Engberg, Robert C.

    2003-01-01

    This paper describes efforts of testing and analysis of various candidate cables and umbilicals for International Space Station microgravity science payloads. The effects of looping, large vs. small displacements, and umbilical mounting configurations were assessed. A 3-DOF stepper motor driven fixture was used to excite the umbilicals. Forces and moments were directly measured in all three axes with a 6-DOF load cell in order to derive suitable stiffness matrices for design and analysis of vibration isolation controllers. Data obtained from these tests were used to help determine the optimum type and configuration of umbilical cables for the International Space Station microgravity science glovebox (MSG) vibration isolation platform. The data and procedures can also be implemented into control algorithm simulations to assist in validation of actively controlled vibration isolation systems. The experimental results of this work are specific in support of the Glovebox Integrated Microgravity Isolation Technology (g-LIMIT) isolation platform, to be located in the microgravity science glovebox aboard the U.S. Destiny Laboratory Module.

  3. Cardiac tamponade due to umbilical venous catheter in the new born

    PubMed Central

    Abdellatif, Mohamed; Ahmed, Ashfag; Alsenaidi, Khalfan

    2012-01-01

    With more and more extreme premature and very low-birth weight babies being resuscitated, umbilical central venous catheterisation is now being used more frequently in neonatal intensive care. The authors present a case of cardiac tamponade following umbilical venous catheterisation in a neonate, an uncommon, yet potentially fatal complication. The patient was diagnosed at the appropriate time by echocardiography and urgent pericardiocentesis proved lifesaving. PMID:22802560

  4. The effects of compound danshen dripping pills and human umbilical cord blood mononuclear cell transplant after acute myocardial infarction.

    PubMed

    Jun, Yi; Chunju, Yuan; Qi, Ai; Liuxia, Deng; Guolong, Yu

    2014-04-01

    The low frequency of survival of stem cells implanted in the myocardium after acute myocardial infarction may be caused by inflammation and oxidative stress in the myocardial microenvironment. We evaluated the effects of a traditional Chinese medicine, Compound Danshen Dripping Pills, on the cardiac microenvironment and cardiac function when used alone or in combination with human umbilical cord blood mononuclear cell transplant after acute myocardial infarction. After surgically induced acute myocardial infarction, rabbits were treated with Compound Danshen Dripping Pills alone or in combination with human umbilical cord blood mononuclear cell transplant. Evaluation included histology, measurement of left ventricular ejection fraction and fractional shortening, leukocyte count, count of green fluorescent protein positive cells, superoxide dismutase activity, and malondialdehyde content. Combination treatment with Compound Danshen Dripping Pills and human umbilical cord blood mononuclear cell transplant significantly increased the survival of implanted cells, inhibited cardiac cell apoptosis, decreased oxidative stress, decreased the inflammatory response, and improved cardiac function. Rabbits treated with either Compound Danshen Dripping Pills or human umbilical cord blood mononuclear cells alone had improvement in these effects compared with untreated control rabbits. Combination therapy with Compound Danshen Dripping Pills and human umbilical cord blood mononuclear cells may improve cardiac function and morphology after acute myocardial infarction.

  5. Hypoxic ischemic encephalopathy in newborns linked to placental and umbilical cord abnormalities.

    PubMed

    Nasiell, Josefine; Papadogiannakis, Nikos; Löf, Erika; Elofsson, Fanny; Hallberg, Boubou

    2016-03-01

    Birth asphyxia and hypoxic ischemic encephalopathy (HIE) of the newborn remain serious complications. We present a study investigating if placental or umbilical cord abnormalities in newborns at term are associated with HIE. A prospective cohort study of the placenta and umbilical cord of infants treated with hypothermia (HT) due to hypoxic brain injury and follow-up at 12 months of age has been carried out. The study population included 41 infants treated for HT whose placentas were submitted for histopathological analysis. Main outcome measures were infant development at 12 months, classified as normal, cerebral palsy, or death. A healthy group of 100 infants without HIE and normal follow-up at 12 months of age were used as controls. A velamentous or marginal umbilical cord insertion and histological abruption was associated with the risk of severe HIE, OR = 5.63, p = 0.006, respectively, OR = 20.3, p = 0.01 (multiple-logistic regression). Velamentous or marginal umbilical cord insertion was found in 39% among HIE cases compared to 7% in controls. Placental and umbilical cord abnormalities have a profound association with HIE. A prompt examination of the placentas of newborns suffering from asphyxia can provide important information on the pathogenesis behind the incident and contribute to make a better early prognosis.

  6. Umbilical Negative Pressure Dressing for Transumbilical Appendectomy in Childern.

    PubMed

    Seifarth, Federico G; Kundu, Neilendu; Guerron, Alfredo D; Garland, Mary M; Gaffley, Michaela W G; Worley, Sarah; Knight, Colin G

    2016-01-01

    Transumbilical laparoscopic-assisted appendectomy (TULAA) carries a high risk for surgical site infection. We investigated the effect of a bio-occlusive umbilical vacuum dressing on wound infection rates after TULAA for patients with acute appendicitis and compared to it with a conventional 3-port appendectomy with a nonvacuum dressing. This study was a retrospective chart review of 1377 patients (2-20 years) undergoing laparoscopic appendectomy for acute appendicitis in 2 tertiary care referral centers from January 2007 through December 2012. Twenty-two different operative technique/dressing variations were documented. The 6 technique/dressing groups with >50 patients were assessed, including a total of 1283 patients. The surgical site infection rate of the 220 patients treated with TULAA and application of an umbilical vacuum dressing with dry gauze is 1.8% (95% CI, 0.0-10.3%). This compares to an infection rate of 4.1% (95% CI, 1.3-10.5%) in 97 patients with dry dressing without vacuum. In the 395 patients who received an umbilical vacuum dressing with gauze and bacitracin, the surgical site infection rate was found to be 4.3% (95% CI, 2.7-6.8%). Application of an umbilical negative-pressure dressing with dry gauze lowers the rate of umbilical site infections in patients undergoing transumbilical laparoscopic-assisted appendectomy for acute appendicitis.

  7. Outcome of sublay mesh repair in non-complicated umbilical hernia with liver cirrhosis and ascites.

    PubMed

    Hassan, Ahmed Mohamed Abdelaziz; Salama, Asaad Fayrouz; Hamdy, Hussam; Elsebae, Magdy Mohamed; Abdelaziz, Ayman Mohamed; Elzayat, Wessam Abdelrahman

    2014-01-01

    Umbilical hernia repair is often accompanied by complications in patients with liver cirrhosis and ascites. It appears that the early elective repair of umbilical hernias in these patients is safer and can be considered for selected patients. The objective of this study is to evaluate the feasibility, safety, complications and technical aspects of sublay mesh repair of umbilical hernia in cirrhotic patients with ascites. Between October 2010 and April 2013, 70 patients with non-complicated umbilical hernia, liver cirrhosis and ascites were enrolled in this study. All patients underwent sublay mesh repair. Demographic data, preoperative variables, peri-operative course, and postoperative complications were recorded and analyzed. A total of 38 women and 32 men underwent operation at an average age 51.24 years. The patients mean MELD score was 18 (range 12-25). The mean operative time was 67.45 min and the average hospital stay was 3.8 days. 2 patients had wound infection, 3 patients developed seroma and 1 patient had an ascitic fistula. Recurrence occurred in 1 (1.4%) patient and no mortality related to the procedure. elective sublay umbilical hernia mesh repair is a safe approach and feasible technique in selected non-complicated cirrhotic patients with ascites. Copyright © 2013 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.

  8. The prevalence of umbilical and epigastric hernia repair: a nationwide epidemiologic study.

    PubMed

    Burcharth, J; Pedersen, M S; Pommergaard, H-C; Bisgaard, T; Pedersen, C B; Rosenberg, J

    2015-10-01

    Umbilical and epigastric hernia repair are common surgical procedures; however, the nationwide gender and age-specific prevalence of these repairs is unknown, and this knowledge could form the basis for new studies. A nationwide register-based study covering all people living in Denmark on December 31st, 2010 was performed. Within this population all umbilical and epigastric hernia repairs from January 1st, 2006 to December 31st, 2010 were identified using data from the Danish National Hospital Register, and 5-year prevalence estimates were calculated. The study population covered 5,639,885 persons (49 % males). A total of 10,107 patients (68 % males) were operated for an umbilical hernia and 2412 patients (55 % males) were operated for an epigastric hernia. The age-specific 5-year prevalence differed for both hernia types. The highest 5-year prevalence of umbilical hernia repairs was seen in males aged 60-70 years with a 5-year prevalence of 0.53 % (95 % CI 0.51-0.56 %) and the highest age-specific 5-year prevalence of epigastric hernia repair was seen in 40-50 year females with a 5-year prevalence of 0.086 % (95 % CI 0.077-0.095 %). The gender and age-specific 5-year prevalence of umbilical and epigastric hernia repair differed in a nationwide population.

  9. Spontaneous endometriosis associated with an umbilical hernia: A case report and review of the literature.

    PubMed

    Ismael, Hishaam; Ragoza, Yury; Harden, Angela; Cox, Steven

    2017-01-01

    Umbilical endometriosis occurring in the presence of an underlying hernia is extremely rare and presents a diagnostic challenge for the general surgeon. We present an interesting case and perform a comprehensive review of the literature. Medline and PubMed were queried for all cases of spontaneous umbilical endometriosis associated with an umbilical hernia. Data was analyzed and is presented along with an interesting case. Only 7 cases have been reported in the literature. Median age was 38 years. Time to presentation was long (up to 5 years) and the majority had cyclical symptoms related to menstruation. All patients, including our case, were treated surgically. Spontaneous umbilical endometriosis with an underlying hernia is often missed preoperatively. Preoperative suspicion warrants axial imaging for better operative planning and patient counseling. Surgery consists of enbloc excision of the umbilicus, implant and the hernia sac to avoid residual disease and reduce recurrence. The hernia defect can be repaired primarily or using mesh and the umbilicus reconstructed using skin flaps if necessary. Surgery is the mainstay of therapy for umbilical endometriosis associated with an underlying hernia. Clinical suspicion warrants preoperative imaging, and follow-up with a gynecologist is essential to address any pelvic disease. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  10. Coiled-coil protein composition of 22 proteomes--differences and common themes in subcellular infrastructure and traffic control.

    PubMed

    Rose, Annkatrin; Schraegle, Shannon J; Stahlberg, Eric A; Meier, Iris

    2005-11-16

    Long alpha-helical coiled-coil proteins are involved in diverse organizational and regulatory processes in eukaryotic cells. They provide cables and networks in the cyto- and nucleoskeleton, molecular scaffolds that organize membrane systems and tissues, motors, levers, rotating arms, and possibly springs. Mutations in long coiled-coil proteins have been implemented in a growing number of human diseases. Using the coiled-coil prediction program MultiCoil, we have previously identified all long coiled-coil proteins from the model plant Arabidopsis thaliana and have established a searchable Arabidopsis coiled-coil protein database. Here, we have identified all proteins with long coiled-coil domains from 21 additional fully sequenced genomes. Because regions predicted to form coiled-coils interfere with sequence homology determination, we have developed a sequence comparison and clustering strategy based on masking predicted coiled-coil domains. Comparing and grouping all long coiled-coil proteins from 22 genomes, the kingdom-specificity of coiled-coil protein families was determined. At the same time, a number of proteins with unknown function could be grouped with already characterized proteins from other organisms. MultiCoil predicts proteins with extended coiled-coil domains (more than 250 amino acids) to be largely absent from bacterial genomes, but present in archaea and eukaryotes. The structural maintenance of chromosomes proteins and their relatives are the only long coiled-coil protein family clearly conserved throughout all kingdoms, indicating their ancient nature. Motor proteins, membrane tethering and vesicle transport proteins are the dominant eukaryote-specific long coiled-coil proteins, suggesting that coiled-coil proteins have gained functions in the increasingly complex processes of subcellular infrastructure maintenance and trafficking control of the eukaryotic cell.

  11. Coiled-coil protein composition of 22 proteomes – differences and common themes in subcellular infrastructure and traffic control

    PubMed Central

    Rose, Annkatrin; Schraegle, Shannon J; Stahlberg, Eric A; Meier, Iris

    2005-01-01

    Background Long alpha-helical coiled-coil proteins are involved in diverse organizational and regulatory processes in eukaryotic cells. They provide cables and networks in the cyto- and nucleoskeleton, molecular scaffolds that organize membrane systems and tissues, motors, levers, rotating arms, and possibly springs. Mutations in long coiled-coil proteins have been implemented in a growing number of human diseases. Using the coiled-coil prediction program MultiCoil, we have previously identified all long coiled-coil proteins from the model plant Arabidopsis thaliana and have established a searchable Arabidopsis coiled-coil protein database. Results Here, we have identified all proteins with long coiled-coil domains from 21 additional fully sequenced genomes. Because regions predicted to form coiled-coils interfere with sequence homology determination, we have developed a sequence comparison and clustering strategy based on masking predicted coiled-coil domains. Comparing and grouping all long coiled-coil proteins from 22 genomes, the kingdom-specificity of coiled-coil protein families was determined. At the same time, a number of proteins with unknown function could be grouped with already characterized proteins from other organisms. Conclusion MultiCoil predicts proteins with extended coiled-coil domains (more than 250 amino acids) to be largely absent from bacterial genomes, but present in archaea and eukaryotes. The structural maintenance of chromosomes proteins and their relatives are the only long coiled-coil protein family clearly conserved throughout all kingdoms, indicating their ancient nature. Motor proteins, membrane tethering and vesicle transport proteins are the dominant eukaryote-specific long coiled-coil proteins, suggesting that coiled-coil proteins have gained functions in the increasingly complex processes of subcellular infrastructure maintenance and trafficking control of the eukaryotic cell. PMID:16288662

  12. The Umbilical Benz Incision for Reduced Port Surgery in Pediatric Patients

    PubMed Central

    Amano, Hizuru; Kawashima, Hiroshi; Deie, Kyoichi; Murase, Naruhiko; Makita, Satoshi; Yokota, Kazuki; Tanaka, Yujiro

    2015-01-01

    Background and Objectives: For reduced port surgery in pediatric patients, the initial umbilical incision plays an important role in both functional ability and cosmetic impact. Larger umbilical incisions enable better manipulation of forceps, extraction of larger surgical specimens, and easier exteriorization of the intestine for anastomosis. We have pursued an incision of the small pediatric umbilicus that allows for enlargement of the orifice of the abdominal opening with preservation of the natural umbilical profile. This article aims to present a new umbilical incision technique and describe the outcomes. Methods: We devised a new umbilical incision technique for reduced port surgery in pediatric patients. Our incision is made in an inverted Y shape (Benz incision), allowing for access port device insertion. The Benz incision technique was applied between November 2010 and May 2014 and was retrospectively studied. Results: Seventy-five patients underwent Benz incisions. The median age of all patients was 6 years 6 months (range, 26 days to 18 years), and the median body weight was 21.7 kg (range, 3.1–54.3 kg). Benz incisions were applied for various procedures, including reduced port surgery with hepaticojejunostomy for congenital biliary dilatation, portojejunostomy for biliary atresia, Meckel diverticulectomy, tumor resection, varicocelectomy, cholecystectomy, splenectomy, ileus surgery, ileocecal resection, and total colectomy. All patients were successfully treated, without a significant increase in operating time or severe complications. The cosmetic profile of the umbilicus was maintained after surgery. Conclusion: The Benz incision is a feasible, effective, and scarless approach for reduced port surgery in pediatric patients whose umbilical rings are too small for the conventional approach. PMID:25848185

  13. Tacrolimus placental transfer at delivery and neonatal exposure through breast milk.

    PubMed

    Zheng, Songmao; Easterling, Thomas R; Hays, Karen; Umans, Jason G; Miodovnik, Menachem; Clark, Shannon; Calamia, Justina C; Thummel, Kenneth E; Shen, Danny D; Davis, Connie L; Hebert, Mary F

    2013-12-01

    The current investigation aims to provide new insights into fetal exposure to tacrolimus in utero by evaluating maternal and umbilical cord blood (venous and arterial), plasma and unbound concentrations at delivery. This study also presents a case report of tacrolimus excretion via breast milk. Maternal and umbilical cord (venous and arterial) samples were obtained at delivery from eight solid organ allograft recipients to measure tacrolimus and metabolite bound and unbound concentrations in blood and plasma. Tacrolimus pharmacokinetics in breast milk were assessed in one subject. Mean (±SD) tacrolimus concentrations at the time of delivery in umbilical cord venous blood (6.6 ± 1.8 ng ml(-1)) were 71 ± 18% (range 45-99%) of maternal concentrations (9.0 ± 3.4 ng ml(-1)). The mean umbilical cord venous plasma (0.09 ± 0.04 ng ml(-1)) and unbound drug concentrations (0.003 ± 0.001 ng ml(-1)) were approximately one fifth of the respective maternal concentrations. Arterial umbilical cord blood concentrations of tacrolimus were 100 ± 12% of umbilical venous concentrations. In addition, infant exposure to tacrolimus through the breast milk was less than 0.3% of the mother's weight-adjusted dose. Differences between maternal and umbilical cord tacrolimus concentrations may be explained in part by placental P-gp function, greater red blood cell partitioning and higher haematocrit levels in venous cord blood. The neonatal drug exposure to tacrolimus via breast milk is very low and likely does not represent a health risk to the breastfeeding infant. © 2013 The Authors. British Journal of Clinical Pharmacology © 2013 The British Pharmacological Society.

  14. The feasibility of local anesthesia for the surgical treatment of umbilical hernia: a systematic review of the literature.

    PubMed

    Jairam, A P; Kaufmann, R; Muysoms, F; Jeekel, J; Lange, J F

    2017-04-01

    Yearly approximately 4500 umbilical hernias are repaired in The Netherlands, mostly under general anesthesia. The use of local anesthesia has shown several advantages in groin hernia surgery. Local anesthesia might be useful in the treatment of umbilical hernia as well. However, convincing evidence is lacking. We have conducted a systematic review on safety, feasibility, and advantages of local anesthesia for umbilical hernia repair. A systematic review was conducted according to the PRISMA guidelines. Outcome parameters were duration of surgery, surgical site infection, perioperative and postoperative complications, postoperative pain, hernia recurrence, time before discharge, and patient satisfaction. The systematic review resulted in nine included articles. Various anesthetic agents were used, varying from short acting to longer acting agents. There was no consensus regarding the injection technique and no conversions to general anesthesia were described. The most common postoperative complication was surgical site infection, with an overall percentage of 3.4%. There were no postoperative deaths and no allergic reactions described for local anesthesia. The hernia recurrence rate varied from 2 to 7.4%. Almost 90% of umbilical hernia patients treated with local anesthesia were discharged within 24 h, compared with 47% of patients treated with general anesthesia. The overall patient satisfaction rate varied from 89 to 97%. Local anesthesia for umbilical hernia seems safe and feasible. However, the advantages of local anesthesia are not sufficiently demonstrated, due to the heterogeneity of included studies. We, therefore, propose a randomized controlled trial comparing general versus local anesthesia for umbilical hernia repair.

  15. Umbilical metastasis or Sister Mary Joseph's nodule as a very early sign of an occult cecal adenocarcinoma.

    PubMed

    Salemis, Nikolaos S

    2007-01-01

    Umbilical metastasis (Sister Mary Joseph's nodule) is a rare occurrence and indicates, in most of the patients, an advanced intraabdominal malignancy. It may be the first sign of an underlying adenocarcinoma, originating mainly from the gastrointestinal or genitourinary tract. An extremely rare case of a Sister Mary Joseph's nodule is described herein, where the metastatic umbilical nodule was the first sign of a cecal adenocarcinoma and became evident 8 months before the onset of the disease. Diagnostic evaluation and surgical management are discussed along with a review of the literature. This case is presented in order to emphasize the need for thorough investigation of any umbilical lesion especially in elderly patients.

  16. Orion Service Module Umbilical (OSMU) Installation on Mobile Launcher (ML)

    NASA Image and Video Library

    2017-03-13

    Cranes and rigging are being used to lift the bracket for the Orion Service Module Umbilical (OSMU) up for installation on the mobile launcher tower. The tower will be equipped with a number of lines, called umbilicals, that will connect to the Space Launch System rocket and Orion spacecraft for Exploration Mission-1 (EM-1). The OSMU will be located high on the mobile launcher tower and, prior to launch, will transfer liquid coolant for the electronics and air for the Environmental Control System to the Orion service module that houses these critical systems to support the spacecraft. EM-1 is scheduled to launch in 2018. The Ground Systems Development and Operations Program is overseeing installation of the umbilicals.

  17. Orion Service Module Umbilical (OSMU) Lift & Preparation for Ins

    NASA Image and Video Library

    2017-03-13

    Preparations are underway to lift the bracket for the Orion Service Module Umbilical (OSMU) up for installation on the mobile launcher tower at NASA's Kennedy Space Center in Florida. The mobile launcher tower will be equipped with a number of lines, called umbilicals, that will connect to the Space Launch System rocket and Orion spacecraft for Exploration Mission-1 (EM-1). The OSMU will be located high on the mobile launcher tower and, prior to launch, will transfer liquid coolant for the electronics and air for the Environmental Control System to the Orion service module that houses these critical systems to support the spacecraft. EM-1 is scheduled to launch in 2018. The Ground Systems Development and Operations Program is overseeing installation of the umbilicals.

  18. Orion Service Module Umbilical (OSMU) Installation

    NASA Image and Video Library

    2017-03-16

    A crane and rigging are used to lift the Orion Service Module Umbilical (OSMU) up for installation on the mobile launcher tower at NASA's Kennedy Space Center in Florida. The mobile launcher tower will be equipped with a number of lines, called umbilicals, that will connect to the Space Launch System rocket and Orion spacecraft for Exploration Mission-1 (EM-1). The OSMU will be located high on the mobile launcher tower and, prior to launch, will transfer liquid coolant for the electronics and air for the Environmental Control System to the Orion service module that houses these critical systems to support the spacecraft. EM-1 is scheduled to launch in 2018. The Ground Systems Development and Operations Program is overseeing installation of the umbilicals.

  19. Orion Service Module Umbilical (OSMU) Installation

    NASA Image and Video Library

    2017-03-16

    Preparations are underway to lift the Orion Service Module Umbilical (OSMU) up for installation on the mobile launcher tower at NASA's Kennedy Space Center in Florida. The mobile launcher tower will be equipped with a number of lines, called umbilicals, that will connect to the Space Launch System rocket and Orion spacecraft for Exploration Mission-1 (EM-1). The OSMU will be located high on the mobile launcher tower and, prior to launch, will transfer liquid coolant for the electronics and air for the Environmental Control System to the Orion service module that houses these critical systems to support the spacecraft. EM-1 is scheduled to launch in 2018. The Ground Systems Development and Operations Program is overseeing installation of the umbilicals.

  20. Orion Service Module Umbilical (OSMU) Installation

    NASA Image and Video Library

    2017-03-16

    Seeming to hang in midair, the Orion Service Module Umbilical (OSMU) is lifted high up by crane for installation on the mobile launcher tower at NASA's Kennedy Space Center in Florida. The mobile launcher tower will be equipped with a number of lines, called umbilicals, that will connect to the Space Launch System rocket and Orion spacecraft for Exploration Mission-1 (EM-1). The OSMU will be located high on the mobile launcher tower and, prior to launch, will transfer liquid coolant for the electronics and air for the Environmental Control System to the Orion service module that houses these critical systems to support the spacecraft. EM-1 is scheduled to launch in 2018. The Ground Systems Development and Operations Program is overseeing installation of the umbilicals.

  1. Orion Service Module Umbilical (OSMU) Installation

    NASA Image and Video Library

    2017-03-16

    A crane and rigging are used to position the Orion Service Module Umbilical (OSMU) for installation high up on the mobile launcher tower at NASA's Kennedy Space Center in Florida. The mobile launcher tower will be equipped with a number of lines, called umbilicals, that will connect to the Space Launch System rocket and Orion spacecraft for Exploration Mission-1 (EM-1). The OSMU will be located high on the mobile launcher tower and, prior to launch, will transfer liquid coolant for the electronics and air for the Environmental Control System to the Orion service module that houses these critical systems to support the spacecraft. EM-1 is scheduled to launch in 2018. The Ground Systems Development and Operations Program is overseeing installation of the umbilicals.

  2. Orion Service Module Umbilical (OSMU) Lift & Preparation for Ins

    NASA Image and Video Library

    2017-03-13

    A crane positions the bracket for the Orion Service Module Umbilical (OSMU) for installation on the mobile launcher tower at NASA's Kennedy Space Center in Florida. The mobile launcher tower will be equipped with a number of lines, called umbilicals, that will connect to the Space Launch System rocket and Orion spacecraft for Exploration Mission-1 (EM-1). The OSMU will be located high on the mobile launcher tower and, prior to launch, will transfer liquid coolant for the electronics and air for the Environmental Control System to the Orion service module that houses these critical systems to support the spacecraft. EM-1 is scheduled to launch in 2018. The Ground Systems Development and Operations Program is overseeing installation of the umbilicals.

  3. Orion Service Module Umbilical (OSMU) Installation

    NASA Image and Video Library

    2017-03-16

    A crane and rigging are used to lift the Orion Service Module Umbilical (OSMU) high up for installation on the mobile launcher tower at NASA's Kennedy Space Center in Florida. The mobile launcher tower will be equipped with a number of lines, called umbilicals, that will connect to the Space Launch System rocket and Orion spacecraft for Exploration Mission-1 (EM-1). The OSMU will be located high on the mobile launcher tower and, prior to launch, will transfer liquid coolant for the electronics and air for the Environmental Control System to the Orion service module that houses these critical systems to support the spacecraft. EM-1 is scheduled to launch in 2018. The Ground Systems Development and Operations Program is overseeing installation of the umbilicals.

  4. Orion Service Module Umbilical (OSMU) Lift & Preparation for Ins

    NASA Image and Video Library

    2017-03-13

    A crane lifts the bracket for the Orion Service Module Umbilical (OSMU) high up for installation on the mobile launcher tower at NASA's Kennedy Space Center in Florida. The mobile launcher tower will be equipped with a number of lines, called umbilicals, that will connect to the Space Launch System rocket and Orion spacecraft for Exploration Mission-1 (EM-1). The OSMU will be located high on the mobile launcher tower and, prior to launch, will transfer liquid coolant for the electronics and air for the Environmental Control System to the Orion service module that houses these critical systems to support the spacecraft. EM-1 is scheduled to launch in 2018. The Ground Systems Development and Operations Program is overseeing installation of the umbilicals.

  5. ICPSU Install onto Mobile Launcher

    NASA Image and Video Library

    2018-03-16

    A heavy-lift crane slowly lifts the Interim Cryogenic Propulsion Stage Umbilical (ICPSU) high up for installation on the tower of the mobile launcher (ML) at NASA's Kennedy Space Center in Florida. The last of the large umbilicals to be installed, the ICPSU will provide super-cooled hydrogen and liquid oxygen to the Space Launch System (SLS) rocket's interim cryogenic propulsion stage, or upper stage, at T-0 for Exploration Mission-1. The umbilical is located at about the 240-foot-level of the mobile launcher and will supply fuel, oxidizer, gaseous helium, hazardous gas leak detection, electrical commodities and environment control systems to the upper stage of the SLS rocket during launch. Exploration Ground Systems is overseeing installation of the umbilicals on the ML.

  6. ICPSU Install onto Mobile Launcher

    NASA Image and Video Library

    2018-03-16

    A crane and rigging lines are used to install the Interim Cryogenic Propulsion Stage Umbilical (ICPSU) high up on the mobile launcher (ML) at NASA's Kennedy Space Center in Florida. The last of the large umbilicals to be installed, the ICPSU will provide super-cooled hydrogen and liquid oxygen to the Space Launch System (SLS) rocket's interim cryogenic propulsion stage, or upper stage, at T-0 for Exploration Mission-1. The umbilical is located at about the 240-foot-level of the mobile launcher and will supply fuel, oxidizer, gaseous helium, hazardous gas leak detection, electrical commodities and environment control systems to the upper stage of the SLS rocket during launch. Exploration Ground Systems is overseeing installation of the umbilicals on the ML.

  7. ICPSU Install onto Mobile Launcher - Preps for Lift

    NASA Image and Video Library

    2018-03-15

    Construction workers with JP Donovan assist with preparations to lift and install the Interim Cryogenic Propulsion Stage Umbilical on the tower of the mobile launcher at NASA's Kennedy Space Center in Florida. The last of the large umbilicals to be installed, the ICPSU will provide super-cooled hydrogen and liquid oxygen to the Space Launch System (SLS) rocket's interim cryogenic propulsion stage, or upper stage, at T-0 for Exploration Mission-1. The umbilical is located at about the 240-foot-level of the mobile launcher and will supply fuel, oxidizer, gaseous helium, hazardous gas leak detection, electrical commodities and environment control systems to the upper stage of the SLS rocket during launch. Exploration Ground Systems is overseeing installation of the umbilicals on the ML.

  8. ICPSU Install onto Mobile Launcher

    NASA Image and Video Library

    2018-03-16

    Construction workers with JP Donovan install the Interim Cryogenic Propulsion Stage Umbilical (ICPSU) at about the 240-foot-level of the mobile launcher (ML) tower at NASA's Kennedy Space Center in Florida. The last of the large umbilicals to be installed, the ICPSU will provide super-cooled hydrogen and liquid oxygen to the Space Launch System (SLS) rocket's interim cryogenic propulsion stage, or upper stage, at T-0 for Exploration Mission-1. The umbilical is located at about the 240-foot-level of the mobile launcher and will supply fuel, oxidizer, gaseous helium, hazardous gas leak detection, electrical commodities and environment control systems to the upper stage of the SLS rocket during launch. Exploration Ground Systems is overseeing installation of the umbilicals on the ML.

  9. ICPSU Install onto Mobile Launcher

    NASA Image and Video Library

    2018-03-16

    A heavy-lift crane slowly lifts the Interim Cryogenic Propulsion Stage Umbilical (ICPSU) up for installation on the tower of the mobile launcher (ML) at NASA's Kennedy Space Center in Florida. The last of the large umbilicals to be installed, the ICPSU will provide super-cooled hydrogen and liquid oxygen to the Space Launch System (SLS) rocket's interim cryogenic propulsion stage, or upper stage, at T-0 for Exploration Mission-1. The umbilical is located at about the 240-foot-level of the mobile launcher and will supply fuel, oxidizer, gaseous helium, hazardous gas leak detection, electrical commodities and environment control systems to the upper stage of the SLS rocket during launch. Exploration Ground Systems is overseeing installation of the umbilicals on the ML.

  10. ICPSU Install onto Mobile Launcher - Preps for Lift

    NASA Image and Video Library

    2018-03-15

    The mobile launcher (ML) tower is lit up before early morning sunrise at NASA's Kennedy Space Center in Florida. Preparations are underway to lift and install the Interim Cryogenic Propulsion Stage Umbilical (ICPSU) at about the 240-foot-level on the tower. The last of the large umbilicals to be installed, the ICPSU will provide super-cooled hydrogen and liquid oxygen to the Space Launch System (SLS) rocket's interim cryogenic propulsion stage, or upper stage, at T-0 for Exploration Mission-1. The umbilical will supply fuel, oxidizer, gaseous helium, hazardous gas leak detection, electrical commodities and environment control systems to the upper stage of the SLS rocket during launch. Exploration Ground Systems is overseeing installation of the umbilicals on the ML.

  11. Flood Syndrome: Spontaneous Umbilical Hernia Rupture Leaking Ascitic Fluid—A Case Report

    PubMed Central

    Nguyen, Emilie T; Tudtud-Hans, Leah A

    2017-01-01

    Introduction We report a rare case of Flood syndrome, which is a spontaneous rupture of an umbilical hernia. Case Presentation A 42-year-old man with decompensated hepatitis C and alcoholic cirrhosis complicated by ascites and esophageal varices presented with 1 day of ascitic fluid drainage after rupture of a preexisting umbilical hernia associated with diffuse abdominal pain and tenderness. A pigtail drain was placed in the right upper abdominal quadrant to decrease fluid drainage from the abdominal wall defect, allowing it to heal naturally. Discussion The spontaneous rupture of an umbilical hernia in our patient highlights a rare complication with high mortality rates and stresses the challenge of treatment that falls in the area between medical and surgical management. PMID:28678688

  12. Flood Syndrome: Spontaneous Umbilical Hernia Rupture Leaking Ascitic Fluid-A Case Report.

    PubMed

    Nguyen, Emilie T; Tudtud-Hans, Leah A

    2017-01-01

    We report a rare case of Flood syndrome, which is a spontaneous rupture of an umbilical hernia. A 42-year-old man with decompensated hepatitis C and alcoholic cirrhosis complicated by ascites and esophageal varices presented with 1 day of ascitic fluid drainage after rupture of a preexisting umbilical hernia associated with diffuse abdominal pain and tenderness. A pigtail drain was placed in the right upper abdominal quadrant to decrease fluid drainage from the abdominal wall defect, allowing it to heal naturally. The spontaneous rupture of an umbilical hernia in our patient highlights a rare complication with high mortality rates and stresses the challenge of treatment that falls in the area between medical and surgical management.

  13. [Effects of non-saccharomyces albicans metabolic products on the proliferation of human umbilical vein endothelial cell ECV304].

    PubMed

    Chen, Bin; Che, Tuanjie; Bai, Decheng; He, Xiangyi

    2013-04-01

    To evaluate the effects of non-Saccharomyces albicans metabolic products on the cell cycle distribution and proliferation of human umbilical vein endothelial cell ECV304 cells in vitro. The parallel dilution supernatant of Saccharomyces tropicalis, Saccharomyces krusei and Saccharomyces glabrata were prepared, and 1, 4, 16-fold(s) diluted concentration and control group were set up. The line of human umbilical vein endothelial cell ECV304 was cultured in vitro and treated by non-Saccharomyces albicans supernatant. The proliferous effect of ECV304 induced by non-Saccharomyces albicans supernatant after 24, 48, 72 h was detected by the methods of MTT, and the changes of cell density and cycle after 48 h were investigated by inverted microscope and flow cytometry. At the 24th hour, all of the higher concentration (1-fold) of non-Saccharomyces albicans supernatant and the 4-folds diluted Saccharomyces krusei could promote ECV304 proliferation(P < 0.05). After adding various non-Saccharomyces albicans supernatant at 48h and 72th hour, Saccharomyces krusei supernatant and Saccharomyces glabrata supernatant significantly increased proliferation rate of ECV304, while Saccharomyces tropicalis supernatant group showed no significant change no matter which concentration was tested. At 48th hour after adding the non-Saccharomyces albicans supernatant, the ECV304 cells density treated by Saccharomyces krusei supernatant and Saccharomyces glabrata supernatant were significantly higher under the inverted microscope. The G0/G1 population of ECV304 cells decreased while cell proliferation index (PI) increased after incubated with Saccharomyces krusei supernatant and Saccharomyces glabrata supernatant for 48 hours (P < 0.05). Saccharomyces tropicalis group showed no significant change (P > 0.05). The metabolic products of Sacharoymces krusei and Saccharomyces glabrata could induce proliferation of ECV304 cell, which suggests non-Saccharomyces albicans should be undergone more attention clinically in detection and treatment.

  14. Extreme umbilical cord lengths, cord knot and entanglement: Risk factors and risk of adverse outcomes, a population-based study

    PubMed Central

    Kessler, Jörg

    2018-01-01

    Objectives To determine risk factors for short and long umbilical cord, entanglement and knot. Explore their associated risks of adverse maternal and perinatal outcome, including risk of recurrence in a subsequent pregnancy. To provide population based gestational age and sex and parity specific reference ranges for cord length. Design Population based registry study. Setting Medical Birth Registry of Norway 1999–2013. Population All singleton births (gestational age>22weeks<45 weeks) (n = 856 300). Methods Descriptive statistics and odds ratios of risk factors for extreme cord length and adverse outcomes based on logistic regression adjusted for confounders. Main outcome measures Short or long cord (<10th or >90th percentile), cord knot and entanglement, adverse pregnancy outcomes including perinatal and intrauterine death. Results Increasing parity, maternal height and body mass index, and diabetes were associated with increased risk of a long cord. Large placental and birth weight, and fetal male sex were factors for a long cord, which again was associated with a doubled risk of intrauterine and perinatal death, and increased risk of adverse neonatal outcome. Anomalous cord insertion, female sex, and a small placenta were associated with a short cord, which was associated with increased risk of fetal malformations, placental complications, caesarean delivery, non-cephalic presentation, perinatal and intrauterine death. At term, cord knot was associated with a quadrupled risk of perinatal death. The combination of a cord knot and entanglement had a more than additive effect to the association to perinatal death. There was a more than doubled risk of recurrence of a long or short cord, knot and entanglement in a subsequent pregnancy of the same woman. Conclusion Cord length is influenced both by maternal and fetal factors, and there is increased risk of recurrence. Extreme cord length, entanglement and cord knot are associated with increased risk of adverse outcomes including perinatal death. We provide population based reference ranges for umbilical cord length. PMID:29584790

  15. The effect of umbilical cord cleansing with chlorhexidine on omphalitis and neonatal mortality in community settings in developing countries: a meta-analysis

    PubMed Central

    2013-01-01

    Background There is an increased risk of serious neonatal infection arising through exposure of the umbilical cord to invasive pathogen in home and facility births where hygienic practices are difficult to achieve. The World Health Organization currently recommends ‘dry cord care’ because of insufficient data in favor of or against topical application of an antiseptic. The primary objective of this meta-analysis is to evaluate the effects of application of chlorhexidine (CHX) to the umbilical cord to children born in low income countries on cord infection (omphalitis) and neonatal mortality. Standardized guidelines of Child Health Epidemiology Reference Group (CHERG) were followed to generate estimates of effectiveness of topical chlorhexidine application to umbilical cord for prevention of sepsis specific mortality, for inclusion in the Lives Saved Tool (LiST). Methods Systematic review and meta-analysis. Data sources included Cochrane Central Register of Controlled Trials (CENTRAL) in the Cochrane Library, PubMed, CINHAL and WHO international clinical trials registry. Only randomized trials were included. Studies of children in hospital settings were excluded. The comparison group received no application to the umbilical cord (dry cord care), no intervention, or a non-CHX intervention. Primary outcomes were omphalitis and all-cause neonatal mortality. Results There were three cluster-randomised community trials (total participants 54,624) conducted in Nepal, Bangladesh and Pakistan that assessed impact of CHX application to the newborn umbilical cord for prevention of cord infection and mortality. Application of any CHX to the umbilical cord of the newborn led to a 23% reduction in all-cause neonatal mortality in the intervention group compared to control [RR 0.77, 95 % CI 0.63, 0.94; random effects model, I2=50 %]. The reduction in omphalitis ranged from 27 % to 56 % compared to control group depending on severity of infection. Based on CHERG rules, effect size for all-cause mortality was used for inclusion to LiST model as a proxy for sepsis specific mortality. Conclusions Application of CHX to newborn umbilical cord can significantly reduce incidence of umbilical cord infection and all-cause mortality among home births in community settings. This inexpensive and simple intervention can save a significant number of newborn lives in developing countries. PMID:24564621

  16. Changes in Doppler flow velocity waveforms and fetal size at 20 weeks gestation among cigarette smokers.

    PubMed

    Kho, E M; North, R A; Chan, E; Stone, P R; Dekker, G A; McCowan, L M E

    2009-09-01

    To compare umbilical and uterine artery Doppler waveforms and fetal size at 20 weeks between smokers and nonsmokers. Prospective cohort study. Auckland, New Zealand and Adelaide, Australia. Nulliparous participants in the Screening for Pregnancy Endpoints (SCOPE) study. Self-reported smoking status was determined at 15 +/- 1 weeks' gestation. At the 20 +/- 1 week anatomy scan, uterine and umbilical Doppler resistance indices (RI) and fetal measurements were compared between smokers and nonsmokers. Umbilical and mean uterine artery Doppler RI values, abnormal umbilical and uterine Doppler (RI > 90th centile) and fetal biometry. Among the 2459 women, 248 (10%) were smokers. Smokers had higher umbilical RI [0.75 (SD 0.06) versus 0.73 (0.06), P < 0.0001] and mean uterine RI [0.59 (0.09) versus 0.56 (0.10), P < 0.0001]. They were twice as likely to have an abnormal umbilical Doppler at 20 weeks compared with nonsmokers [n = 35 (14.6%) versus n = 156 (7.2%), OR 2.21, 95% CI 1.49-3.27]. This effect remained significant after adjusting for age, ethnicity, marital status, employment and BMI (adjusted OR 1.62, 95% CI 1.03-2.54). Smokers were more likely to have an abnormal mean uterine RI [n = 33 (13.7%) versus n = 198 (9.2%), OR 1.57, 95% CI 1.06-2.33], but this association was not significant after adjusting for confounders. Fetuses of women who smoked had a small reduction in femur length and estimated weight compared with nonsmokers. At 20 weeks' gestation, women who smoke have higher umbilical artery RI, a surrogate measure for an abnormal placental villous vascular tree. This may contribute to later fetal growth restriction among smokers. Further research is needed to explore the clinical significance of these findings.

  17. Carbetocin versus intra-umbilical oxytocin in the management of retained placenta: a randomized clinical study.

    PubMed

    Elfayomy, Amr K

    2015-08-01

    This study aimed to compare the hemodynamic profile and efficacy of carbetocin versus intra-umbilical oxytocin in the management of retained placenta following vaginal delivery. In this randomized clinical study, women with retained placenta for more than 30 min were assigned to receive either an i.v. bolus of 100-µg carbetocin (n = 38) or an intra-umbilical vein injection of 50 IU oxytocin in 30 mL saline (n = 40). The main parameters evaluated were the success rate for expulsion of the placenta and the effects of these drugs on maternal blood pressure. The success rate in the carbetocin group was 86.84% compared to 77.5% in the intra-umbilical oxytocin group. Notably, 57.7% of the participants had prior induction of labor or augmentation during labor. There were no significant differences between the two groups regarding the estimated blood loss, drop of hemoglobin within the first 48 h, additional uterotonic injection or the need for manual removal of the placenta. Systolic blood pressure was significantly lower in the intra-umbilical oxytocin group at 30 and 60 min after injection (P = 0.008, 0.026, respectively). Nonetheless, diastolic blood pressure was significantly lower in the intra-umbilical oxytocin group than in the carbetocin group at 30 min (P = 0.036). A single i.v. bolus of carbetocin and umbilical vein injection of 50 IU oxytocin are similarly effective in reducing the need for manual removal of the placenta. Carbetocin seems to have an acceptable hemodynamic safety profile and can be used as an alternative choice to the conventional oxytocic agents in the management of retained placenta. © 2015 The Authors. Journal of Obstetrics and Gynaecology Research © 2015 Japan Society of Obstetrics and Gynecology.

  18. Evaluation of three high abundance protein depletion kits for umbilical cord serum proteomics

    PubMed Central

    2011-01-01

    Background High abundance protein depletion is a major challenge in the study of serum/plasma proteomics. Prior to this study, most commercially available kits for depletion of highly abundant proteins had only been tested and evaluated in adult serum/plasma, while the depletion efficiency on umbilical cord serum/plasma had not been clarified. Structural differences between some adult and fetal proteins (such as albumin) make it likely that depletion approaches for adult and umbilical cord serum/plasma will be variable. Therefore, the primary purposes of the present study are to investigate the efficiencies of several commonly-used commercial kits during high abundance protein depletion from umbilical cord serum and to determine which kit yields the most effective and reproducible results for further proteomics research on umbilical cord serum. Results The immunoaffinity based kits (PROTIA-Sigma and 5185-Agilent) displayed higher depletion efficiency than the immobilized dye based kit (PROTBA-Sigma) in umbilical cord serum samples. Both the PROTIA-Sigma and 5185-Agilent kit maintained high depletion efficiency when used three consecutive times. Depletion by the PROTIA-Sigma Kit improved 2DE gel quality by reducing smeared bands produced by the presence of high abundance proteins and increasing the intensity of other protein spots. During image analysis using the identical detection parameters, 411 ± 18 spots were detected in crude serum gels, while 757 ± 43 spots were detected in depleted serum gels. Eight spots unique to depleted serum gels were identified by MALDI- TOF/TOF MS, seven of which were low abundance proteins. Conclusions The immunoaffinity based kits exceeded the immobilized dye based kit in high abundance protein depletion of umbilical cord serum samples and dramatically improved 2DE gel quality for detection of trace biomarkers. PMID:21554704

  19. Umbilical cord CD71+ erythroid cells are reduced in neonates born to women in spontaneous preterm labor.

    PubMed

    Gomez-Lopez, Nardhy; Romero, Roberto; Xu, Yi; Miller, Derek; Unkel, Ronald; C MacKenzie, Tippi; Frascoli, Michela; Hassan, Sonia S

    2016-10-01

    Preterm neonates are highly susceptible to infection. Neonatal host defense against infection seems to be maintained by the temporal presence of immunosuppressive CD71+ erythroid cells. The aim of this study was to investigate whether umbilical cord CD71+ erythroid cells are reduced in neonates born to women who undergo spontaneous preterm labor/birth. Umbilical cord blood samples (n=155) were collected from neonates born to women who delivered preterm with (n=39) and without (n=12) spontaneous labor or at term with (n=82) and without (n=22) spontaneous labor. Time-matched maternal peripheral blood samples were also included (n=111). Mononuclear cells were isolated from these samples, and CD71+ erythroid cells were identified and quantified as CD3-CD235a+CD71+ cells by flow cytometry. (i) The proportion of CD71+ erythroid cells was 50-fold higher in cord blood than in maternal blood; (ii) a reduced number and frequency of umbilical cord CD71+ erythroid cells were found in neonates born to women who underwent spontaneous preterm labor compared to those born to women who delivered preterm without labor; (iii) umbilical cord CD71+ erythroid cells were fewer in neonates born to term pregnancies, regardless of the process of labor, than in those born to women who delivered preterm without labor; and (iv) no differences were seen in umbilical cord CD71+ erythroid cells between neonates born to women who underwent spontaneous preterm labor and those born to women who delivered at term with labor. Umbilical cord CD71+ erythroid cells are reduced in neonates born to women who had undergone spontaneous preterm labor. Published 2016. This article is a U.S. Government work and is in the public domain in the USA.

  20. Lower reoperation rate for recurrence after mesh versus sutured elective repair in small umbilical and epigastric hernias. A nationwide register study.

    PubMed

    Christoffersen, M W; Helgstrand, F; Rosenberg, J; Kehlet, H; Bisgaard, T

    2013-11-01

    Repair for a small (≤ 2 cm) umbilical and epigastric hernia is a minor surgical procedure. The most common surgical repair techniques are a sutured repair or a repair with mesh reinforcement. However, the optimal repair technique with regard to risk of reoperation for recurrence is not well documented. The aim of the present study was in a nationwide setup to investigate the reoperation rate for recurrence after small open umbilical and epigastric hernia repairs using either sutured or mesh repair. This was a prospective cohort study based on intraoperative registrations from the Danish Ventral Hernia Database (DVHD) of patients undergoing elective open mesh and sutured repair for small (≤ 2 cm) umbilical and epigastric hernias. Patients were included during a 4-year study period. A complete follow-up was obtained by combining intraoperative data from the DVHD with data from the Danish National Patient Register. The cumulative reoperation rates were obtained using cumulative incidence plot and compared with the log rank test. In total, 4,786 small (≤ 2 cm) elective open umbilical and epigastric hernia repairs were included. Age was median 48 years (range 18-95 years). Follow-up was 21 months (range 0-47 months). The cumulated reoperation rates for recurrence were 2.2 % for mesh reinforcement and 5.6 % for sutured repair (P = 0.001). The overall cumulated reoperation rate for sutured and mesh repairs was 4.8 %. In conclusion, reoperation rate for recurrence for small umbilical and epigastric hernias was significantly lower after mesh repair compared with sutured repair. Mesh reinforcement should be routine in even small umbilical or epigastric hernias to lower the risk of reoperation for recurrence avoid recurrence.

  1. An umbilical polyp in an infant.

    PubMed

    Swanson, David L; Pakzad, Betty

    2005-10-01

    The persistence at birth of the omphalomesenteric (vitelline) duct may result in life-threatening consequences. Early identification of this congenital anomaly is essential for prompt surgical treatment to eliminate the risk of prolapse and herniation. A neonatal umbilical polyp may indicate the presence of an omphalomesenteric duct remnant. We describe the diagnosis and surgical treatment of an infant with an umbilical polyp. We also present an overview of the diagnosis and treatment of vitelline duct remnants and their associated anomalies.

  2. Simultaneous isolation of vascular endothelial cells and mesenchymal stem cells from the human umbilical cord.

    PubMed

    Kadam, Sachin S; Tiwari, Shubha; Bhonde, Ramesh R

    2009-01-01

    The umbilical cord represents the link between mother and fetus during pregnancy. This cord is usually discarded as a biological waste after the child's birth; however, its importance as a "store house" of stem cells has been explored recently. We developed a method of simultaneous isolation of endothelial cells (ECs) from the vein and mesenchymal stem cells from umbilical cord Wharton's jelly of the same cord. The isolation protocol has been simplified, modified, and improvised with respect to choice of enzyme and enzyme mixture, digestion time, cell yield, cell growth, and culture medium. Isolated human umbilical vascular ECs (hUVECs) were positive for von-Willibrand factor, a classical endothelial marker, and could form capillary-like structures when seeded on Matrigel, thus proving their functionality. The isolated human umbilical cord mesenchymal stem cells (hUCMSCs) were found positive for CD44, CD90, CD 73, and CD117 and were found negative for CD33, CD34, CD45, and CD105 surface markers; they were also positive for cytoskeleton markers of smooth muscle actin and vimentin. The hUCMSCs showed multilineage differentiation potential and differentiated into adipogenic, chondrogenic, osteogenic, and neuronal lineages under influence of lineage specific differentiation medium. Thus, isolating endothelial cells as well as mesenchymal cells from the same umbilical cord could lead to complete utilization of the available tissue for the tissue engineering and cell therapy.

  3. Double half-cone flap umbilicoplasty for proboscoid umbilical hernia in a 2 years old child with satisfactory results 2 years later.

    PubMed

    Ashu, Eseme Ebai; Leroy, Guifo Marc; Aristide, Bang Guy; Joss, Bitang Mafok Louis; Bonaventure, Jemea; Patrick, Savom Eric; Myriam, Fotso Guegne

    2015-01-01

    Surgical repair of large umbilical hernias may present a challenging surgical problem; standard surgical techniques have proven to be inadequate for both closing the fascial defect of the umbilicus and providing a satisfactory cosmetic result. We describe here a case of double half-cone flap umbilicoplasty that was performed in a 2 years old boy. The case of a 2 years old child with proboscoid umbilical hernia. The protruding umbilical skin was excised sharply by two V-shaped cuts leaving two half cones, a short cephalic (0.5cm) and a long caudal (1cm). A classic herniotomy was carried out, with repair of the facial defect. The caudal half cone was sutured from its apex till half it's length upon itself with interrupted sutures and it was anchored deeply to the fascia. Then we inverted the cephalic half cone which was sutured to the caudal cone to form the new umbilicus. The early result was excellent with no complications and the result after 2years revealed a cosmetically satisfactory shape of the umbilicus. this technique provides a good solution for reconstruction of the protruding umbilical skin and it is easy to learn, easy to be taught and perform in surgical environments and may be applicable for any kind of umbilical reconstruction.

  4. Umbilical cord sparing technique for repair of congenital hernia into the cord and small omphalocele.

    PubMed

    Ceccanti, Silvia; Falconi, Ilaria; Frediani, Simone; Boscarelli, Alessandro; Musleh, Layla; Cozzi, Denis A

    2017-01-01

    Current repair of small omphaloceles and hernias into the umbilical cord is a straightforward procedure, whose repair may result in a suboptimal cosmetic outcome. We describe a novel repair technique retaining the umbilical cord elements in an attempt to improve the cosmetic appearance of the umbilicus. Eight neonates were consecutively treated more than a ten-year period. Size of the fascial defects ranged 1 to 3cm (median, 2). Present technique entails incision of the amniotic sac without its detachment from the skin, reduction of the extruded contents under direct vision, and closure of the abdominal wall defect by circumferential suturing of peritoneum and fascia around the base of the amniotic sac. The amniotic sac is then re-approximated and folded to create an umbilical stump, which is trimmed and left to shed naturally. All patients achieved a scarless abdomen with a normal appearing umbilicus in 6. The remaining 2 patients are awaiting surgery for persisting umbilical hernia repair and umbilicoplasty, respectively. Poor esthetic outcome was significantly associated with initial fascial defect ≥2.5cm in size (p=0.03). Present technique is a simple and cosmetically appealing repair for umbilical cord hernias and small omphaloceles, especially effective when the size of the fascial defect is less than 2.5cm. IV (Treatment Study). Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Double half-cone flap umbilicoplasty for proboscoid umbilical hernia in a 2 years old child with satisfactory results 2 years later

    PubMed Central

    Ashu, Eseme Ebai; Leroy, Guifo Marc; Aristide, Bang Guy; Joss, Bitang Mafok Louis; Bonaventure, Jemea; Patrick, Savom Eric; Myriam, Fotso Guegne

    2015-01-01

    Surgical repair of large umbilical hernias may present a challenging surgical problem; standard surgical techniques have proven to be inadequate for both closing the fascial defect of the umbilicus and providing a satisfactory cosmetic result. We describe here a case of double half-cone flap umbilicoplasty that was performed in a 2 years old boy. The case of a 2 years old child with proboscoid umbilical hernia. The protruding umbilical skin was excised sharply by two V-shaped cuts leaving two half cones, a short cephalic (0.5cm) and a long caudal (1cm). A classic herniotomy was carried out, with repair of the facial defect. The caudal half cone was sutured from its apex till half it's length upon itself with interrupted sutures and it was anchored deeply to the fascia. Then we inverted the cephalic half cone which was sutured to the caudal cone to form the new umbilicus. The early result was excellent with no complications and the result after 2years revealed a cosmetically satisfactory shape of the umbilicus. this technique provides a good solution for reconstruction of the protruding umbilical skin and it is easy to learn, easy to be taught and perform in surgical environments and may be applicable for any kind of umbilical reconstruction. PMID:26664545

  6. Optimization of informed consent for umbilical cord blood banking.

    PubMed

    Sugarman, Jeremy; Kurtzberg, Joanne; Box, Tamara L; Horner, Ronnie D

    2002-12-01

    The purpose of this project was to evaluate the informed consent process for donation to a public umbilical cord blood bank. Telephone interviews were conducted with 170 women who had given consent to donate their newborn infants' umbilical cord blood. Of the 170 women who were contacted, 96.8% of the women reported that all their questions had been answered. Nevertheless, approximately one third of the respondents did not consider themselves to be in research, and almost one quarter of the respondents did not know how to contact the umbilical cord blood bank if they or their infant became seriously ill. Further, a substantial proportion of the respondents did not understand the full range of alternatives to donation and incorrectly endorsed potential benefits. Informed consent could be optimized by (1) having those personnel who obtain consent emphasize that banking involves research and to explain the true benefits of donation, (2) ensuring that parents know how and when to contact the umbilical cord blood bank after donation, and (3) using phone surveys to continue assessments and to monitor changes in the process.

  7. Laparoscopic surgical treatment of umbilical hernia and small eventrations with prosthetic mesh using omentum overlay.

    PubMed

    Bratu, D; Sabău, A; Dumitra, A; Sabău, D; Miheţiu, A; Beli, L; Hulpuş, R

    2014-01-01

    Umbilical hernias and abdominal incisional hernias represent current pathologies which require numerous surgical alternative ways of treatment in prosthetic or non prosthetic,open or minimally invasive surgery. The method proposed by us is a less expensive option with no additional risks compared to other similar procedures as surgical technique. We conducted a retrospective study between 01.01.2008 - 01.06.2013 in which we considered a number of 23 patients with umbilical hernia and eventration, patients who received laparoscopic intraperitoneal polyester mesh covered with omentum, procedure applied at the IInd Surgery Clinic, Clinical County Emergency Hospital Sibiu. Out of 23 patients with postoperative umbilical hernia and eventration cases in which we used this surgical technique,16 were umbilical hernias and 7 post incisional hernias. The average time of surgery was 1 hour and 40 minutes, recording 4 postoperative complications remitted under conservative treatment, with a mean hospitalization of 4.1 days. Proepiploic laparoscopic treatment using omentum is a reliable alternative to a more expensive and difficult procedure involving Dual Mesh. Celsius.

  8. Umbilical hernia in patients with liver cirrhosis: A surgical challenge

    PubMed Central

    Coelho, Julio C U; Claus, Christiano M P; Campos, Antonio C L; Costa, Marco A R; Blum, Caroline

    2016-01-01

    Umbilical hernia occurs in 20% of the patients with liver cirrhosis complicated with ascites. Due to the enormous intraabdominal pressure secondary to the ascites, umbilical hernia in these patients has a tendency to enlarge rapidly and to complicate. The treatment of umbilical hernia in these patients is a surgical challenge. Ascites control is the mainstay to reduce hernia recurrence and postoperative complications, such as wound infection, evisceration, ascites drainage, and peritonitis. Intermittent paracentesis, temporary peritoneal dialysis catheter or transjugular intrahepatic portosystemic shunt may be necessary to control ascites. Hernia repair is indicated in patients in whom medical treatment is effective in controlling ascites. Patients who have a good perspective to be transplanted within 3-6 mo, herniorrhaphy should be performed during transplantation. Hernia repair with mesh is associated with lower recurrence rate, but with higher surgical site infection when compared to hernia correction with conventional fascial suture. There is no consensus on the best abdominal wall layer in which the mesh should be placed: Onlay, sublay, or underlay. Many studies have demonstrated several advantages of the laparoscopic umbilical herniorrhaphy in cirrhotic patients compared with open surgical treatment. PMID:27462389

  9. Umbilical hernia in patients with liver cirrhosis: A surgical challenge.

    PubMed

    Coelho, Julio C U; Claus, Christiano M P; Campos, Antonio C L; Costa, Marco A R; Blum, Caroline

    2016-07-27

    Umbilical hernia occurs in 20% of the patients with liver cirrhosis complicated with ascites. Due to the enormous intraabdominal pressure secondary to the ascites, umbilical hernia in these patients has a tendency to enlarge rapidly and to complicate. The treatment of umbilical hernia in these patients is a surgical challenge. Ascites control is the mainstay to reduce hernia recurrence and postoperative complications, such as wound infection, evisceration, ascites drainage, and peritonitis. Intermittent paracentesis, temporary peritoneal dialysis catheter or transjugular intrahepatic portosystemic shunt may be necessary to control ascites. Hernia repair is indicated in patients in whom medical treatment is effective in controlling ascites. Patients who have a good perspective to be transplanted within 3-6 mo, herniorrhaphy should be performed during transplantation. Hernia repair with mesh is associated with lower recurrence rate, but with higher surgical site infection when compared to hernia correction with conventional fascial suture. There is no consensus on the best abdominal wall layer in which the mesh should be placed: Onlay, sublay, or underlay. Many studies have demonstrated several advantages of the laparoscopic umbilical herniorrhaphy in cirrhotic patients compared with open surgical treatment.

  10. Laparoscopic transabdominal preperitoneal approach for umbilical hernia with rectus diastasis.

    PubMed

    Capitano, Sante

    2017-08-01

    Rectus diastasis, when coexistent with umbilical hernia, can benefit from mesh-based repair of the midline. Laparoscopic correction of an umbilical hernia involves the placement of a mesh in the peritoneal cavity, but this comes with the risk of bowel complications. However, newly developed dual-sided composite meshes have helped to reduce this risk. Four men and three women with umbilical hernia and rectus diastasis were treated with laparoscopic transabdominal preperitoneal repair. Composite mesh with a hydrophilic 3-D polyester textile on the parietal side and an absorbable collagen barrier on the peritoneal side were placed in the preperitoneal pocket after hernial sac reduction. Mean hernia size was 2.5 cm, and no recurrences were observed during the mean follow-up period of 9.2 months. The laparoscopic transabdominal preperitoneal approach for umbilical hernia and rectus diastasis may be a safe surgical option when trying to avoid potential complications related to intra-abdominal mesh positioning. © 2017 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and John Wiley & Sons Australia, Ltd.

  11. Prognosis elements in surgical treatment of complicated umbilical hernia in patients with liver cirrhosis.

    PubMed

    Banu, P; Popa, F; Constantin, V D; Bălălău, C; Nistor, M

    2013-09-15

    The surgical treatment of umbilical hernia in cirrhosis patients raises special management challenges. The attitude upon the repair of these hernias varies from expectancy or elective treatment in early stages of the disease to the surgical treatment only if complications occur. We have assessed 22 consecutive cases of cirrhosis patients treated for complicated umbilical hernia in the Surgical Department of "Sf. Pantelimon" Emergency Hospital in Bucharest between January 2008 and December 2012. The patients' stratification was done in stages of liver disease based upon Child-Pugh classification. Complications that required emergency repair were the following: strangulation, incarceration and hernia rupture. The postoperative complications were ordered in five grades of severity based upon Clavien classification. The severity of the complications was higher in advanced stages of liver cirrhosis, Child B and C. There were 5 deaths representing 22,7%, four of them in patients with Child C disease stage. The incidence of morbidity and mortality after umbilical hernia repair in emergencies increases in advanced stages of liver cirrhosis. It is advisable to prevent complications occurrence and perform surgical repair of umbilical hernia in elective condition.

  12. Protective link for superconducting coil

    DOEpatents

    Umans, Stephen D [Belmont, MA

    2009-12-08

    A superconducting coil system includes a superconducting coil and a protective link of superconducting material coupled to the superconducting coil. A rotating machine includes first and second coils and a protective link of superconducting material. The second coil is operable to rotate with respect to the first coil. One of the first and second coils is a superconducting coil. The protective link is coupled to the superconducting coil.

  13. A matter of health? Legal aspects of private umbilical cord blood banking.

    PubMed

    Vidalis, Takis

    2011-03-01

    Private umbilical cord blood banking raises a question of special legal regulation. This practice promises the safe storage of biological material on the assumption that it may be useful, at a certain moment in future, for its own donor (or for a donor's close family member) for curing serious blood diseases. Although currently the therapeutic value of umbilical cord blood is confirmed, there are strong scientific doubts and relevant controversies regarding its use in autologous transplantations. This fact produces conditions of legal uncertainty, since the benefit for those wanting to conclude contracts with private umbilical cord blood banks is not clear. The Greek example illustrates this situation of regulatory deficit well, which eventually creates a major problem, given the increasing number of private banks offering relevant services in the country.

  14. Orion Service Module Umbilical (OSMU) Lift & Preparation for Ins

    NASA Image and Video Library

    2017-03-13

    Crane specialists monitor the progress as the bracket for the Orion Service Module Umbilical (OSMU) is lifted up for installation on the mobile launcher tower at NASA's Kennedy Space Center in Florida. The mobile launcher tower will be equipped with a number of lines, called umbilicals, that will connect to the Space Launch System rocket and Orion spacecraft for Exploration Mission-1 (EM-1). The OSMU will be located high on the mobile launcher tower and, prior to launch, will transfer liquid coolant for the electronics and air for the Environmental Control System to the Orion service module that houses these critical systems to support the spacecraft. EM-1 is scheduled to launch in 2018. The Ground Systems Development and Operations Program is overseeing installation of the umbilicals.

  15. Orion Service Module Umbilical (OSMU) Installation

    NASA Image and Video Library

    2017-03-16

    Construction workers assist as a crane and rigging are used to position the Orion Service Module Umbilical (OSMU) for installation high up on the mobile launcher tower at NASA's Kennedy Space Center in Florida. The mobile launcher tower will be equipped with a number of lines, called umbilicals, that will connect to the Space Launch System rocket and Orion spacecraft for Exploration Mission-1 (EM-1). The OSMU will be located high on the mobile launcher tower and, prior to launch, will transfer liquid coolant for the electronics and air for the Environmental Control System to the Orion service module that houses these critical systems to support the spacecraft. EM-1 is scheduled to launch in 2018. The Ground Systems Development and Operations Program is overseeing installation of the umbilicals.

  16. Orion Service Module Umbilical (OSMU) Lift & Preparation for Ins

    NASA Image and Video Library

    2017-03-13

    A view from below the mobile launcher shows a crane positioning the bracket for the Orion Service Module Umbilical (OSMU) high up for installation on the mobile launcher tower at NASA's Kennedy Space Center in Florida. The mobile launcher tower will be equipped with a number of lines, called umbilicals, that will connect to the Space Launch System rocket and Orion spacecraft for Exploration Mission-1 (EM-1). The OSMU will be located high on the mobile launcher tower and, prior to launch, will transfer liquid coolant for the electronics and air for the Environmental Control System to the Orion service module that houses these critical systems to support the spacecraft. EM-1 is scheduled to launch in 2018. The Ground Systems Development and Operations Program is overseeing installation of the umbilicals.

  17. Orion Service Module Umbilical (OSMU) Lift & Preparation for Ins

    NASA Image and Video Library

    2017-03-13

    Crane specialists monitor the progress as the bracket for the Orion Service Module Umbilical (OSMU) is lifted high up for installation on the mobile launcher tower at NASA's Kennedy Space Center in Florida. The mobile launcher tower will be equipped with a number of lines, called umbilicals, that will connect to the Space Launch System rocket and Orion spacecraft for Exploration Mission-1 (EM-1). The OSMU will be located high on the mobile launcher tower and, prior to launch, will transfer liquid coolant for the electronics and air for the Environmental Control System to the Orion service module that houses these critical systems to support the spacecraft. EM-1 is scheduled to launch in 2018. The Ground Systems Development and Operations Program is overseeing installation of the umbilicals.

  18. Orion Service Module Umbilical (OSMU) Lift & Preparation for Ins

    NASA Image and Video Library

    2017-03-13

    In this view looking down from high up on the mobile launcher, a crane positions the bracket for the Orion Service Module Umbilical (OSMU) for installation on the mobile launcher tower at NASA's Kennedy Space Center in Florida. The mobile launcher tower will be equipped with a number of lines, called umbilicals, that will connect to the Space Launch System rocket and Orion spacecraft for Exploration Mission-1 (EM-1). The OSMU will be located high on the mobile launcher tower and, prior to launch, will transfer liquid coolant for the electronics and air for the Environmental Control System to the Orion service module that houses these critical systems to support the spacecraft. EM-1 is scheduled to launch in 2018. The Ground Systems Development and Operations Program is overseeing installation of the umbilicals.

  19. ICPSU Install onto Mobile Launcher

    NASA Image and Video Library

    2018-03-16

    The mobile launcher (ML) is reflected in the sunglasses of a construction worker with JP Donovan at NASA's Kennedy Space Center in Florida. A crane is lifting the Interim Cryogenic Propulsion Stage Umbilical (ICPSU) up for installation on the tower of the ML. The last of the large umbilicals to be installed, the ICPSU will provide super-cooled hydrogen and liquid oxygen to the Space Launch System (SLS) rocket's interim cryogenic propulsion stage, or upper stage, at T-0 for Exploration Mission-1. The umbilical is located at about the 240-foot-level of the mobile launcher and will supply fuel, oxidizer, gaseous helium, hazardous gas leak detection, electrical commodities and environment control systems to the upper stage of the SLS rocket during launch. Exploration Ground Systems is overseeing installation of the umbilicals on the ML.

  20. ICPSU Install onto Mobile Launcher - Preps for Lift

    NASA Image and Video Library

    2018-03-15

    A construction worker with JP Donovan helps prepare the Interim Cryogenic Propulsion Stage Umbilical (ICPSU) for installation high up on the tower of the mobile launcher (ML) at NASA's Kennedy Space Center in Florida. The last of the large umbilicals to be installed, the ICPSU will provide super-cooled hydrogen and liquid oxygen to the Space Launch System (SLS) rocket's interim cryogenic propulsion stage, or upper stage, at T-0 for Exploration Mission-1. The umbilical will be located at about the 240-foot-level of the mobile launcher and will supply fuel, oxidizer, gaseous helium, hazardous gas leak detection, electrical commodities and environment control systems to the upper stage of the SLS rocket during launch. Exploration Ground Systems is overseeing installation of the umbilicals on the ML.

  1. ICPSU Install onto Mobile Launcher - Preps for Lift

    NASA Image and Video Library

    2018-03-15

    Construction workers with JP Donovan attach a heavy-lift crane to the Interim Cryogenic Propulsion Stage Umbilical (ICPSU) to prepare for lifting and installation on the mobile launcher (ML) tower at NASA's Kennedy Space Center in Florida. The last of the large umbilicals to be installed, the ICPSU will provide super-cooled hydrogen and liquid oxygen to the Space Launch System (SLS) rocket's interim cryogenic propulsion stage, or upper stage, at T-0 for Exploration Mission-1. The umbilical will be located at about the 240-foot-level of the ML and will supply fuel, oxidizer, gaseous helium, hazardous gas leak detection, electrical commodities and environment control systems to the upper stage of the SLS rocket during launch. Exploration Ground Systems is overseeing installation of the umbilicals on the ML.

  2. [Effectiveness of Sacral Intervertebral Epidural Block for Umbilical Hernia Repair in Children].

    PubMed

    Nagamine, Norimitsu; Furuya, Atsushi; Suzuki, Sho; Kondo, Satoko; Kiuchi, Riko; Suzuki, Satomi; Nonaka, Akihiko

    2015-02-01

    Effectiveness of sacral intervertebral epidural block (S 2-3 block) for umbilical hernia repair has not been clarified. We investigate 24 children, undergoing umbilical hernia repair; mean age of 3 years (age range: 20-65 months). Under general anesthesia, epidural block was performed at S 2-3 interspace with 1 ml x kg(-1) ropivacaine (0.2%) at injecting rate of 1 ml x sec(-1) followed by 0.25 ml x kg(-1) normal saline. In all cases, neither systolic blood pressure nor heart rate increased > 15% from those just before the block. Postoperative analgesics were given in 6 patients (25%) rectally. Mean time between the block and the administration of analgesic was 10.5 hours. S 2-3 block can be effective for postoperative pain in umbilical hernia repair.

  3. Investigations of SBS and Laser Gain Competition in High-Power Phase Modulated Fiber Amplifiers (Postprint)

    DTIC Science & Technology

    2014-02-26

    through RF filtering . Subsequently, this modulated signal is used in a cutback experiment with a passive fiber . Studies describing enhancement factors...to filter out higher order modes [3]. However, in order to maintain single-mode (diffraction limited) operation, conventional step-index fiber core...Letters 36, 2686-2688 (2011). [3] J. P. Koplaw, D. Kliner, and L. Goldberg, “Single-mode operation of a coiled multimode fiber amplifier,” Optics Letters

  4. Magnetic field transfer device and method

    DOEpatents

    Wipf, S.L.

    1990-02-13

    A magnetic field transfer device includes a pair of oppositely wound inner coils which each include at least one winding around an inner coil axis, and an outer coil which includes at least one winding around an outer coil axis. The windings may be formed of superconductors. The axes of the two inner coils are parallel and laterally spaced from each other so that the inner coils are positioned in side-by-side relation. The outer coil is outwardly positioned from the inner coils and rotatable relative to the inner coils about a rotational axis substantially perpendicular to the inner coil axes to generate a hypothetical surface which substantially encloses the inner coils. The outer coil rotates relative to the inner coils between a first position in which the outer coil axis is substantially parallel to the inner coil axes and the outer coil augments the magnetic field formed in one of the inner coils, and a second position 180[degree] from the first position, in which the augmented magnetic field is transferred into the other inner coil and reoriented 180[degree] from the original magnetic field. The magnetic field transfer device allows a magnetic field to be transferred between volumes with negligible work being required to rotate the outer coil with respect to the inner coils. 16 figs.

  5. Magnetic field transfer device and method

    DOEpatents

    Wipf, Stefan L.

    1990-01-01

    A magnetic field transfer device includes a pair of oppositely wound inner coils which each include at least one winding around an inner coil axis, and an outer coil which includes at least one winding around an outer coil axis. The windings may be formed of superconductors. The axes of the two inner coils are parallel and laterally spaced from each other so that the inner coils are positioned in side-by-side relation. The outer coil is outwardly positioned from the inner coils and rotatable relative to the inner coils about a rotational axis substantially perpendicular to the inner coil axes to generate a hypothetical surface which substantially encloses the inner coils. The outer coil rotates relative to the inner coils between a first position in which the outer coil axis is substantially parallel to the inner coil axes and the outer coil augments the magnetic field formed in one of the inner coils, and a second position 180.degree. from the first position, in which the augmented magnetic field is transferred into the other inner coil and reoriented 180.degree. from the original magnetic field. The magnetic field transfer device allows a magnetic field to be transferred between volumes with negligible work being required to rotate the outer coil with respect to the inner coils.

  6. Klotho gene delivery ameliorates renal hypertrophy and fibrosis in streptozotocin-induced diabetic rats by suppressing the Rho-associated coiled-coil kinase signaling pathway.

    PubMed

    Deng, Minghong; Luo, Yumei; Li, Yunkui; Yang, Qiuchen; Deng, Xiaoqin; Wu, Ping; Ma, Houxun

    2015-07-01

    The present study aimed to investigate whether klotho gene delivery attenuated renal hypertrophy and fibrosis in streptozotocin-induced diabetic rats. A recombinant adeno-associated virus (rAAV) carrying mouse klotho full-length cDNA (rAAV.mKL), was constructed for in vivo investigation of klotho expression. Diabetes was induced in rats by a single tail vein injection of 60 mg/kg streptozotocin. Subsequently, the diabetic rats received an intravenous injection of rAAV.mKL, rAAV.green fluorescent protein (GFP) or phosphate-buffered saline (PBS). The Sprague-Dawley rat group received PBS and served as the control group. After 12 weeks, all the rats were sacrificed and ELISA, immunohistochemical and histological analyses, fluorescence microscopy, semi-quantitative reverse transcription-polymerase chain reaction and western blottin were performed. A single dose of rAAV.mKL was found to prevent the progression of renal hypertrophy and fibrosis for at least 12 weeks (duration of study). Klotho expression was suppressed in the diabetic rats, but was increased by rAAV.mKL delivery. rAAV.mKL significantly suppressed diabetes-induced renal hypertrophy and histopathological changes, reduced renal collagen fiber generation and decreased kidney hypertrophy index. In addition, rAAV.mKL decreased the protein expression levels of fibronectin and vimentin, while it downregulated the mRNA expression and activity of Rho-associated coiled-coil kinase (ROCK)I in the kidneys of the diabetic rats. These results indicated that klotho gene delivery ameliorated renal hypertrophy and fibrosis in diabetic rats, possibly by suppressing the ROCK signaling pathway. This may offer a novel approach for the long-term control and renoprotection of diabetes.

  7. Umbilical cord blood banking: implications for perinatal care providers.

    PubMed

    Armson, B Anthony

    2005-03-01

    To evaluate the risks and benefits of umbilical cord blood banking for future stem cell transplantation and to provide guidelines for Canadian perinatal care providers regarding the counselling, procedural, and ethical implications of this potential therapeutic option. Selective or routine collection and storage of umbilical cord blood for future autologous (self) or allogenic (related or unrelated) transplantation of hematopoietic stem cells to treat malignant and nonmalignant disorders in children and adults. Maternal and perinatal morbidity, indications for umbilical cord blood transplantation, short- and long-term risks and benefits of umbilical cord blood transplantation, burden of umbilical cord blood collection on perinatal care providers, parental satisfaction, and health care costs. MEDLINE and PubMed searches were conducted from January 1970 to October 2003 for English-language articles related to umbilical cord blood collection, banking, and transplantation; the Cochrane library was searched; and committee opinions of the Royal College of Obstetricians and Gynaecologists, the American Academy of Pediatrics, and the American College of Obstetricians and Gynecologists were obtained. The evidence collected was reviewed and evaluated by the Maternal/Fetal Medicine Committee of the Society of Obstetricians and Gynaecologists of Canada (SOGC), and recommendations were made using the evaluation of evidence guidelines developed by the Canadian Task Force on the Periodic Health Exam. Umbilical cord blood is a readily available source of hematopoietic stem cells used with increasing frequency as an alternative to bone marrow or peripheral stem cells for transplantation in the treatment of malignant and nonmalignant conditions in children and adults. Umbilical cord blood transplantation provides a rich source of hematopoietic stem cells with several advantages, including prompt availability, decreased risk of transmissible viral infections and graft-versus-host disease (GVHD) in both human leukocyte antigen(HLA)-matched and HLA-mismatched stem cell transplants, and ease of collection with little risk to the mother or newborn. Potential limitations of umbilical cord blood transplantation include insufficient stem cell dose to reliably treat larger children and adult recipients, slower rate of engraftment, and the potential for transfer of genetically abnormal hematopoietic stem cells. The optimum method of umbilical cord blood transplantation is not yet clear, though available evidence would favour collection before delivery of the placenta. There are many unresolved ethical issues related to umbilical cord blood banking, particularly related to the rapid growth of private, for-profit, cord blood banks offering long-term storage for potential future autologous or related allogenic transplantation. The financial burden to the health care system for public cord blood banking and to families for private cord blood collection and storage is considerable. 1. Perinatal care providers should be informed about the promising clinical potential of hematopoietic stem cells in umbilical cord blood and about current indications for its collection, storage, and use, based on sound scientific evidence (II-3B). 2. Umbilical cord blood collection should be considered for a sibling or parent in need of stem cell transplantation when an HLA-identical bone marrow cell or peripheral stem cell donation from a sibling or parent is unavailable for transplantation (II-2B). 3. Umbilical cord blood should be considered when allogeneic transplantation is the treatment of choice for a child who does not have an HLA-identical sibling or a well-matched, unrelated adult bone marrow donor (II-2B). 4. Umbilical cord blood should be considered for allogeneic transplantation in adolescents and young adults with hematologic malignancies who have no suitable bone marrow donor and who require urgent transplantation (II-3B). 5. Altruistic donation of cord blood for public banking and subsequent allogeneic transplantation should be encouraged when umbilical cord blood banking is being considered by childbearing women, prenatal care providers, and(or) obstetric facilities (II-2B). 6. Collection and long-term storage of umbilical cord blood for autologous donation is not recommended because of the limited indications and lack of scientific evidence to support the practice (III-D). 7. Birth unit staff should receive training in standardized cord blood unit volume and reduce the rejection rate owing to labelling problems, bacterial contamination, and clotting (II-3B). 8. The safe management of obstetric delivery should never be compromised to facilitate cord blood collection. Manoeuvres to optimize cord blood unit volume, such as early clamping of the umbilical cord, may be employed at the discretion of the perinatal care team, provided the safety of the mother and newborn remains the major priority (III-A). 9. Collection of cord blood should be performed after the delivery of the infant but before delivery of the placenta, using a closed collection system and procedures that minimize risk of bacterial and maternal fluid contamination (see Figures 1a-1c) (I-B). 10. Public and private cord blood banks should strictly adhere to standardized policies and procedures for transportation, safety testing, HLA typing, cryopreservation, and long-term storage of umbilical cord blood units to prevent harm to the recipient, to eliminate the risk of transmitting communicable diseases, and thus to maximize the effectiveness of umbilical cord blood stem cell transplantation (II-1A). 11. Canada should establish registration, regulation, and accreditation of cord blood collection centres and banks (III-B). 12. Recruitment of cord blood donors should be fair and noncoercive. Criteria to ensure an equitable recruitment process include the following: (a) adequate supply to meet population transplantation needs; (b) fair distribution of the burdens and benefits of cord blood collection; (c) optimal timing of recruitment; (d) appropriately trained personnel; and (e) accurate recruitment message (III-A). 13. Informed consent for umbilical cord blood collection and banking should be obtained during prenatal care, before the onset of labour, with confirmation of consent after delivery (III-B). 14. Linkage of cord blood units and donors is recommended for public safety. Policies regarding the disclosure of abnormal test results to donor parents should be developed. Donor privacy and confidentiality of test results must be respected (III-C). 15. Commercial cord blood banks should be carefully regulated to ensure that promotion and pricing practices are fair, financial relationships are transparent, banked cord blood is stored and used according to approved standards, and parents and care providers understand the differences between autologous versus allogenic donations and private versus public banks (III-B). 16. Policies and procedures need to be developed by perinatal facilities and national health authorities to respond to prenatal requests for public and private cord blood banking (III-C).

  8. Sildenafil citrate for the management of fetal growth restriction and oligohydramnios

    PubMed Central

    Choudhary, Rana; Desai, Kavita; Parekh, Hetal; Ganla, Kedar

    2016-01-01

    Fetal growth restriction (FGR) and preeclampsia are the major causes of neonatal morbidity and mortality, which affect up to 8% of all pregnancies. The pathogenesis in FGR is an abnormal trophoblastic invasion leading to compromised uteroplacental circulation. However, in spite of this understanding and identification of high-risk patients, the management options are limited. There are some new studies which have demonstrated the role of sildenafil citrate in improving vasodilatation of small myometrial vessels and therefore improvement in amniotic fluid index, fetal weight, and even uterine and umbilical artery Doppler patterns. We report here the case of a 31-year-old female with infertility and preconceptional thin endometrium responding well to sildenafil citrate, followed by conception. However, she presented with an early-onset FGR at 26 weeks of gestation, and again after treatment with sildenafil citrate, showed improvement in amniotic fluid index and fetal weight, finally resulting in delivery of a full-term healthy baby with uneventful neonatal course. PMID:27563258

  9. The conception, birth, and growth of a missile umbilical system

    NASA Technical Reports Server (NTRS)

    Nordman, G. W.

    1977-01-01

    The design development was traced for the sprint 2 and improved sprint 2 missile system (ISMS) umbilical system. The unique system requirements, umbilical designs considered to meet the requirements, and the problems encountered and solutions derived during the design, and development testing of the selected systems are described. The sprint 2 development effort consisted of design, analysis, and testing activities. The ISMS effort involved the performance of an extensive trade study to determine the optimum design to meet the ISMS conditions.

  10. Testing of the X-33 umbilical system at KSC

    NASA Technical Reports Server (NTRS)

    1999-01-01

    At the Launch Equipment Test Facility, , Will Reaves and Mike Solomon (kneeling), both with Lockheed Martin Technical Operations, observe parts of the X-33 umbilical system during testing. A team of Kennedy Space Center experts developed the umbilical system, comprising panels, valves and hoses that provide the means to load the X-33 with super-cold propellant. The X-33, under construction at Lockheed Martin Skunk Works in Palmdale, Calif., is a half-scale prototype of the planned operational reusable launch vehicle dubbed VentureStar.

  11. Robots Would Couple And Uncouple Fluid And Electrical Lines

    NASA Technical Reports Server (NTRS)

    Del Castillo, Eduardo Lopez; Davis, Virgil; Ferguson, Bob; Reichle, Garland

    1992-01-01

    Robots make and break connections between umbilical plates and mating connectors on rockets about to be launched. Sensing and control systems include vision, force, and torque subsystems. Enhances safety by making it possible to couple and uncouple umbilical plates quickly, without exposing human technicians to hazards of leaking fuels and oxidizers. Significantly reduces time spent to manually connect umbilicals. Robots based on similar principles used in refueling of National AeroSpace Plane (NASP) and satellites and orbital transfer vehicles in space.

  12. Safety and Tolerability of HSC835 in Patients With Hematological Malignancies Undergoing Single Umbilical Cord Blood Transplant

    ClinicalTrials.gov

    2017-08-31

    Single Umbilical Cord Blood Transplantation; Non-myeloablative Conditioning; Acute Lymphocytic Leukemia; Myelodysplastic Syndrome; Non-Hodgkin's Lymphoma; Multiple Myeloma; Chronic Lymphocytic Leukemia

  13. Conformational switching in the coiled-coil domains of a proteasomal ATPase regulates substrate processing.

    PubMed

    Snoberger, Aaron; Brettrager, Evan J; Smith, David M

    2018-06-18

    Protein degradation in all domains of life requires ATPases that unfold and inject proteins into compartmentalized proteolytic chambers. Proteasomal ATPases in eukaryotes and archaea contain poorly understood N-terminally conserved coiled-coil domains. In this study, we engineer disulfide crosslinks in the coiled-coils of the archaeal proteasomal ATPase (PAN) and report that its three identical coiled-coil domains can adopt three different conformations: (1) in-register and zipped, (2) in-register and partially unzipped, and (3) out-of-register. This conformational heterogeneity conflicts with PAN's symmetrical OB-coiled-coil crystal structure but resembles the conformational heterogeneity of the 26S proteasomal ATPases' coiled-coils. Furthermore, we find that one coiled-coil can be conformationally constrained even while unfolding substrates, and conformational changes in two of the coiled-coils regulate PAN switching between resting and active states. This switching functionally mimics similar states proposed for the 26S proteasome from cryo-EM. These findings thus build a mechanistic framework to understand regulation of proteasome activity.

  14. Molecular basis of coiled-coil oligomerization-state specificity.

    PubMed

    Ciani, Barbara; Bjelic, Saša; Honnappa, Srinivas; Jawhari, Hatim; Jaussi, Rolf; Payapilly, Aishwarya; Jowitt, Thomas; Steinmetz, Michel O; Kammerer, Richard A

    2010-11-16

    Coiled coils are extensively and successfully used nowadays to rationally design multistranded structures for applications, including basic research, biotechnology, nanotechnology, materials science, and medicine. The wide range of applications as well as the important functions these structures play in almost all biological processes highlight the need for a detailed understanding of the factors that control coiled-coil folding and oligomerization. Here, we address the important and unresolved question why the presence of particular oligomerization-state determinants within a coiled coil does frequently not correlate with its topology. We found an unexpected, general link between coiled-coil oligomerization-state specificity and trigger sequences, elements that are indispensable for coiled-coil formation. By using the archetype coiled-coil domain of the yeast transcriptional activator GCN4 as a model system, we show that well-established trimer-specific oligomerization-state determinants switch the peptide's topology from a dimer to a trimer only when inserted into the trigger sequence. We successfully confirmed our results in two other, unrelated coiled-coil dimers, ATF1 and cortexillin-1. We furthermore show that multiple topology determinants can coexist in the same trigger sequence, revealing a delicate balance of the resulting oligomerization state by position-dependent forces. Our experimental results should significantly improve the prediction of the oligomerization state of coiled coils. They therefore should have major implications for the rational design of coiled coils and consequently many applications using these popular oligomerization domains.

  15. Umbilical Cord Blood: Information for Childbirth Educators

    PubMed Central

    Waller-Wise, Renece

    2011-01-01

    Umbilical cord blood was once thought of as a waste product. Now, years after the first successful umbilical cord blood transplant, more families seek information about whether or not to save their newborn’s cord blood. Childbirth educators may be one of the main sources that an expectant family depends on to gain more knowledge about cord blood banking in order to make an informed decision. Preserving umbilical cord blood in public banks is advisable for any family; however, it is recommended that expectant families only consider private cord blood banking when they have a relative with a known disorder that is treatable by stem cell transplants. The childbirth educator is encouraged to be well versed on the topic of cord blood banking, so that as questions from class participants arise, the topic can be explored and addressed appropriately. PMID:22211060

  16. Type II single umbilical artery (persistent vitelline artery) in an otherwise normal fetus.

    PubMed

    Gamzu, Ronni; Zalel, Yaron; Jacobson, Jeffrey M; Screiber, Leticia; Achiron, Reuven

    2002-11-01

    A single umbilical artery resulting from absence of the umbilical arteries and persistence of the vitelline artery that arises directly from the abdominal aorta has been described only in malformed fetuses with sirenomelia or caudal regression. Such an aberrant artery was suggested to be the etiology of sirenomelia caused by a 'steal' mechanism of blood flow from the caudal end of the embryo. We present a case in which prenatal ultrasound showed a similar aberrant single artery arising from the abdominal aorta in an otherwise normal fetus with a normal course of pregnancy. This vessel, a continuation of the superior mesenteric artery (SMA), corresponds to a persistent vitelline artery assuming the function of the umbilical arteries. The etiology of such a finding and its possible consequences are discussed. Copyright 2002 John Wiley & Sons, Ltd.

  17. Triple dye plus rubbing alcohol versus triple dye alone for umbilical cord care.

    PubMed

    Suliman, Alawia K; Watts, Heidi; Beiler, Jessica; King, Tonya S; Khan, Sana; Carnuccio, Marybeth; Paul, Ian M

    2010-01-01

    Current practices for umbilical cord care vary across centers, but the evidence regarding these practices and their impact on cord separation, complications, and health care use are limited. The objective of this study was to compare the effect of triple dye alone (brilliant green, crystal violet, and proflavine hemisulfate) versus triple dye plus rubbing alcohol (isopropyl alcohol) twice daily on time to umbilical cord separation, complications, and health care use. For the 90 newborns who completed the study, there were no significant differences between treatment groups for time to cord separation, cord-related morbidities, or cord-related urgent care. Based on these study results, there does not appear to be significant benefit to the addition of twice daily applications of rubbing alcohol to neonatal umbilical cords following triple dye treatment after birth.

  18. Orion Service Module Umbilical (OSMU) Lift & Preparation for Ins

    NASA Image and Video Library

    2017-03-13

    Construction workers and crane specialists high up on the mobile launcher tower monitor the progress as a crane positions the bracket for the Orion Service Module Umbilical (OSMU) for installation on the mobile launcher tower at NASA's Kennedy Space Center in Florida. The tower will be equipped with a number of lines, called umbilicals, that will connect to the Space Launch System rocket and Orion spacecraft for Exploration Mission-1 (EM-1). The OSMU will be located high on the mobile launcher tower and, prior to launch, will transfer liquid coolant for the electronics and air for the Environmental Control System to the Orion service module that houses these critical systems to support the spacecraft. EM-1 is scheduled to launch in 2018. The Ground Systems Development and Operations Program is overseeing installation of the umbilicals.

  19. Regulation of malonyl-CoA-acyl carrier protein transacylase network in umbilical cord blood affected by intrauterine hyperglycemia.

    PubMed

    Zhang, Yong; Ye, Jianping; Fan, Jianxia

    2017-09-26

    Gestational diabetes mellitus (GDM) has been shown to be associated with high risk of diabetes in offspring. However, the mechanisms involved in the insulin resistance in offspring are still unclear. Mitochondrial dysfunction is related with insulin resistance. In mitochondria, malonyl-CoA-acyl carrier protein transacylase (MCAT) is the key enzyme of mitochondrial fatty acid synthesis and is estimated to contribute to insulin resistance. In this study, we aimed to examine the role of MCAT and its network in the umbilical cord blood in GDM-induced offspring insulin resistance. We isolated lymphocytes from umbilical cord vein blood in 6 GDM patients and 6 controls and examined the differences of RNA by RNA sequencing. qRT-PCR and western blot were used to measure mRNA and protein changes. Bisulfite genomic sequencing PCR was applied to detect DNA methylation. We found more than 400 genes were differentially regulated in the lymphocytes of umbilical cord blood from GDM patients and these genes were mainly enriched in immune system and endocrine system, which relate to mitochondrial dysfunction and insulin resistance. MCAT closely related with PTPN1 (Protein Tyrosine Phosphatase, Non-Receptor Type1) and STAT5A (Signal Transducer And Activator of Transcription 5A), which were all increased in umbilical cord blood from GDM patients. Increase in MCAT may be due to decreased MCAT DNA methylation. MCAT and its network with PTPN1, STAT5A are regulated in umbilical cord blood affected by maternal intrauterine hyperglycemia.

  20. Is human umbilical cord the most suitable substrate for the detection of endomysium antibodies in the screening and follow-up of coeliac disease?

    PubMed

    Sategna-Guidetti, C; Grosso, S B; Bruno, M; Grosso, S

    1997-07-01

    Immunoglobulin A (IgA) anti-endomysium antibodies, the most reliable immunological marker for both the screening and follow-up of coeliac disease, need monkey oesophagus as antigenic substrate; this limits their use because of high costs and the exploitation of endangered species. (1) To compare the diagnostic accuracy of anti-endomysium antibodies detected by indirect immunofluorescence on monkey oesophagus and on human umbilical cord; (2) to evaluate their reliability during follow-up in detecting non-compliant patients. One hundred and four untreated adults with biopsy-proven coeliac disease and 94 controls were investigated. Endomysium antibodies were found in 99 patients (95%) on both substrates, with a specificity, respectively, of 100% and 99% on monkey oesophagus and umbilical cord. One year after gluten withdrawal, out of 47 patients who were investigated, only six presented with complete mucosal recovery: none of these subjects was positive on either substrates, while, among patients with persistent histological alterations, endomysium positivity persisted in only 10 on monkey oesophagus, but in 32 on umbilical cord. Histology (recovery or persistent involvement) was in agreement with endomysium (negative or positive) in 34% on monkey oesophagus, but in 81% on umbilical cord (P < 0.0001). Human umbilical cord, with its comparable diagnostic efficiency, could replace monkey tissues, with the advantages of saving both money and monkeys. Moreover, it seems the most suitable substrate in the follow-up, as it enables detection of non-compliant patients with persisting mucosal alterations.

  1. [Without Net and Double Floor: Comparison of Umbilical Hernia Repair by Spitzy in Children and Adults].

    PubMed

    Kuck, Laura; Seitz, Florian; Wiegering, Armin; Dietz, Ulrich; Meyer, Thomas

    2017-11-22

    Summary Umbilical hernia occur in both adults and children. For over 100 years, umbilical hernia in children has been treated surgically by the Spitzy method. With adult patients, meshes are being increasingly used. The purpose of our study was to analyse Spitzy herniotomy with respect to the recurrence rate in children and adults. Material and Methods Over a period of 7 years, 383 children (age < 16 years) with umbilical hernia were treated surgically; after applying the exclusion criteria, 370 patients were evaluated. At the same time, 106 adult patients (age > 16 years) were operated for an umbilical hernia: 31 patients were treated with direct suture and thus are included in our study as comparison group. Results The young patients had an average age of 33.81 months and were 44% female and 56% male. After direct Spitzy suture, a low recurrence rate of 1.1% (n = 4) in infancy could be achieved. The average age of the adult patients was 54.55 years; 32% were female, 68% male. In comparison to the group of children, the recurrence rate in adult surgery was 12.9% (n = 4) after direct suture. Conclusion As confirmed in our study, umbilical herniotomy by direct suture in childhood has been the method of choice and gold standard for more than 100 years. Mesh implantation is still not necessary in childhood. Georg Thieme Verlag KG Stuttgart · New York.

  2. A new type of coil structure called pan-shaped coil of wireless charging system based on magnetic resonance

    NASA Astrophysics Data System (ADS)

    Yue, Z. K.; Liu, Z. Z.; Hou, Y. J.; Zeng, H.; Liang, L. H.; Cui, S.

    2017-11-01

    The problem that misalignment between the transmitting coil and the receiving coil significantly impairs the transmission power and efficiency of the system has been attached more and more attention. In order to improve the uniformity of the magnetic field between the two coils to solve this problem, a new type of coil called pan-shaped coil is proposed. Three-dimension simulation models of the planar-core coil and the pan-shaped coil are established using Ansoft Maxwell software. The coupling coefficient between the transmitting coil and the receiving coil is obtained by simulating the magnetic field with the receiving coil misalignment or not. And the maximum percentage difference strength along the radial direction which is defined as the magnetic field uniformity factor is calculated. According to the simulation results of the two kinds of coil structures, it is found that the new type of coil structure can obviously improve the uniformity of the magnetic field, coupling coefficient and power transmission properties between the transmitting coil and the receiving coil.

  3. Improvement of wireless power transmission efficiency of implantable subcutaneous devices by closed magnetic circuit mechanism.

    PubMed

    Jo, Sung-Eun; Joung, Sanghoon; Suh, Jun-Kyo Francis; Kim, Yong-Jun

    2012-09-01

    Induction coils were fabricated based on flexible printed circuit board for inductive transcutaneous power transmission. The coil had closed magnetic circuit (CMC) structure consisting of inner and outer magnetic core. The power transmission efficiency of the fabricated device was measured in the air and in vivo condition. It was confirmed that the CMC coil had higher transmission efficiency than typical air-core coil. The power transmission efficiency during a misalignment between primary coil and implanted secondary coil was also evaluated. The decrease of mutual inductance between the two coils caused by the misalignment led to a low efficiency of the inductive link. Therefore, it is important to properly align the primary coil and implanted secondary coil for effective power transmission. To align the coils, a feedback coil was proposed. This was integrated on the backside of the primary coil and enabled the detection of a misalignment of the primary and secondary coils. As a result of using the feedback coil, the primary and secondary coils could be aligned without knowledge of the position of the implanted secondary coil.

  4. Two-Port Laparoscopic Reconstructive Surgery of the Urinary Tract with Reusable Umbilical System (Hybrid Less): A Proof of Concept Study.

    PubMed

    Angulo, Javier C; Pérez, Sergio; García-Tello, Ana; Redondo, Cristina; Meilán, Elisa; Arance, Ignacio

    2016-01-01

    We compared perioperative results and complications of reconstructive surgery of the urinary tract performed using a multichannel platform through the umbilicus and one additional 3.5-mm with a cohort of patients simultaneously treated with conventional 4-port laparoscopy. Matched-pair study comparing perioperative outcomes, postoperative visual analogue pain scale (VAPS) and morbidity of 2-port (n = 20) and 4-port (n = 10) laparoscopic reconstructive urological surgery. Preoperative and perioperative data compared included demographics, type of surgery, operative time, blood loss, decrease in serum hemoglobin, operative complications, length of stay and postoperative complications according to Clavien-Dindo classification. There was no significant difference between groups regarding age, gender, body mass index, American Society of Anesthesiologists score, type of surgery, operative time, operative complications and intraoperative or postoperative transfusion. Estimated blood loss was lower using reduced-port approach. VAPS at postoperative day one was significantly lower for 2-port approach and so was the length of stay. Patient satisfaction with the wound was higher for 2-port surgery. Differences were not observed in number and severity of postoperative complications. Urological reconstructive operations can be safely performed using the hybrid laparoendoscopic single-site umbilical approach, resulting in lower blood loss, higher patient satisfaction and lower postoperative pain, which also facilitate earlier hospital discharge, than the same reconstructive procedures performed through multiport conventional laparoscopy. © 2016 S. Karger AG, Basel.

  5. The structure of the GemC1 coiled coil and its interaction with the Geminin family of coiled-coil proteins

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Caillat, Christophe; Fish, Alexander; Pefani, Dafni-Eleftheria

    The GemC1 coiled-coil structure has subtle differences compared with its homologues Geminin and Idas. Co-expression experiments in cells and biophysical stability analysis of the Geminin-family coiled coils suggest that the GemC1 coiled coil alone is unstable. GemC1, together with Idas and Geminin, an important regulator of DNA-replication licensing and differentiation decisions, constitute a superfamily sharing a homologous central coiled-coil domain. To better understand this family of proteins, the crystal structure of a GemC1 coiled-coil domain variant engineered for better solubility was determined to 2.2 Å resolution. GemC1 shows a less typical coiled coil compared with the Geminin homodimer and themore » Geminin–Idas heterodimer structures. It is also shown that both in vitro and in cells GemC1 interacts with Geminin through its coiled-coil domain, forming a heterodimer that is more stable that the GemC1 homodimer. Comparative analysis of the thermal stability of all of the possible superfamily complexes, using circular dichroism to follow the unfolding of the entire helix of the coiled coil, or intrinsic tryptophan fluorescence of a unique conserved N-terminal tryptophan, shows that the unfolding of the coiled coil is likely to take place from the C-terminus towards the N-terminus. It is also shown that homodimers show a single-state unfolding, while heterodimers show a two-state unfolding, suggesting that the dimer first falls apart and the helices then unfold according to the stability of each protein. The findings argue that Geminin-family members form homodimers and heterodimers between them, and this ability is likely to be important for modulating their function in cycling and differentiating cells.« less

  6. N‐Acetylcysteine, a glutathione precursor, reverts vascular dysfunction and endothelial epigenetic programming in intrauterine growth restricted guinea pigs

    PubMed Central

    Herrera, Emilio A.; Cifuentes‐Zúñiga, Francisca; Figueroa, Esteban; Villanueva, Cristian; Hernández, Cherie; Alegría, René; Arroyo‐Jousse, Viviana; Peñaloza, Estefania; Farías, Marcelo; Uauy, Ricardo; Casanello, Paola

    2016-01-01

    Key points Intrauterine growth restriction (IUGR) is associated with vascular dysfunction, oxidative stress and signs of endothelial epigenetic programming of the umbilical vessels.There is no evidence that this epigenetic programming is occurring on systemic fetal arteries.In IUGR guinea pigs we studied the functional and epigenetic programming of endothelial nitric oxide synthase (eNOS) (Nos3 gene) in umbilical and systemic fetal arteries, addressing the role of oxidative stress in this process by maternal treatment with N‐acetylcysteine (NAC) during the second half of gestation.The present study suggests that IUGR endothelial cells have common molecular markers of programming in umbilical and systemic arteries. Notably, maternal treatment with NAC restores fetal growth by increasing placental efficiency and reverting the functional and epigenetic programming of eNOS in arterial endothelium in IUGR guinea pigs. Abstract In humans, intrauterine growth restriction (IUGR) is associated with vascular dysfunction, oxidative stress and signs of endothelial programming in umbilical vessels. We aimed to determine the effects of maternal antioxidant treatment with N‐acetylcysteine (NAC) on fetal endothelial function and endothelial nitric oxide synthase (eNOS) programming in IUGR guinea pigs. IUGR was induced by implanting ameroid constrictors on uterine arteries of pregnant guinea pigs at mid gestation, half of the sows receiving NAC in the drinking water (from day 34 until term). Fetal biometry and placental vascular resistance were followed by ultrasound throughout gestation. At term, umbilical arteries and fetal aortae were isolated to assess endothelial function by wire‐myography. Primary cultures of endothelial cells (ECs) from fetal aorta, femoral and umbilical arteries were used to determine eNOS mRNA levels by quantitative PCR and analyse DNA methylation in the Nos3 promoter by pyrosequencing. Doppler ultrasound measurements showed that NAC reduced placental vascular resistance in IUGR (P < 0.05) and recovered fetal weight (P < 0.05), increasing fetal‐to‐placental ratio at term (∼40%) (P < 0.001). In IUGR, NAC treatment restored eNOS‐dependent relaxation in aorta and umbilical arteries (P < 0.05), normalizing eNOS mRNA levels in EC fetal and umbilical arteries (P < 0.05). IUGR‐derived ECs had a decreased DNA methylation (∼30%) at CpG −170 (from the transcription start site) and this epigenetic signature was absent in NAC‐treated fetuses (P < 0.001). These data show that IUGR‐ECs have common molecular markers of eNOS programming in umbilical and systemic arteries and this effect is prevented by maternal treatment with antioxidants. PMID:27739590

  7. A periodic table of coiled-coil protein structures.

    PubMed

    Moutevelis, Efrosini; Woolfson, Derek N

    2009-01-23

    Coiled coils are protein structure domains with two or more alpha-helices packed together via interlacing of side chains known as knob-into-hole packing. We analysed and classified a large set of coiled-coil structures using a combination of automated and manual methods. This led to a systematic classification that we termed a "periodic table of coiled coils," which we have made available at http://coiledcoils.chm.bris.ac.uk/ccplus/search/periodic_table. In this table, coiled-coil assemblies are arranged in columns with increasing numbers of alpha-helices and in rows of increased complexity. The table provides a framework for understanding possibilities in and limits on coiled-coil structures and a basis for future prediction, engineering and design studies.

  8. A portable wireless power transmission system for video capsule endoscopes.

    PubMed

    Shi, Yu; Yan, Guozheng; Zhu, Bingquan; Liu, Gang

    2015-01-01

    Wireless power transmission (WPT) technology can solve the energy shortage problem of the video capsule endoscope (VCE) powered by button batteries, but the fixed platform limited its clinical application. This paper presents a portable WPT system for VCE. Besides portability, power transfer efficiency and stability are considered as the main indexes of optimization design of the system, which consists of the transmitting coil structure, portable control box, operating frequency, magnetic core and winding of receiving coil. Upon the above principles, the correlation parameters are measured, compared and chosen. Finally, through experiments on the platform, the methods are tested and evaluated. In the gastrointestinal tract of small pig, the VCE is supplied with sufficient energy by the WPT system, and the energy conversion efficiency is 2.8%. The video obtained is clear with a resolution of 320×240 and a frame rate of 30 frames per second. The experiments verify the feasibility of design scheme, and further improvement direction is discussed.

  9. Fetal umbilical artery Doppler pulsatility index and childhood neurocognitive outcome at 12 years

    PubMed Central

    Mone, Fionnuala; McConnell, Barbara; Thompson, Andrew; Segurado, Ricardo; Hepper, Peter; Stewart, Moira C; Dornan, James C; Ong, Stephen; McAuliffe, Fionnuala M; Shields, Michael D

    2016-01-01

    Objective To determine whether an elevated fetal umbilical artery Doppler (UAD) pulsatility index (PI) at 28 weeks’ gestation, in the absence of fetal growth restriction (FGR) and prematurity, is associated with adverse neurocognitive outcome in children aged 12 years. Methods Prospective cohort study, comparing children with a normal fetal UAD PI (<90th centile) (n=110) and those with an elevated PI (≥90th centile) (n=40). UAD was performed at 28, 32 and 34 weeks gestation. At 12 years of age, all children were assessed under standardised conditions at Queen's University, Belfast, UK to determine cognitive and behavioural outcomes using the British Ability Score-II and Achenbach Child Behavioural Checklist Parent Rated Version under standardised conditions. Regression analysis was performed, controlling for confounders such as gender, socioeconomic status and age at assessment. Results The mean age of follow-up was 12.4 years (±0.5 SD) with 44% of children male (n=63). When UAD was assessed at 28 weeks, the elevated fetal UAD group had lower scores in cognitive assessments of information processing and memory. Parameters included (1) recall of objects immediate verbal (p=0.002), (2) delayed verbal (p=0.008) and (3) recall of objects immediate spatial (p=0.0016). There were no significant differences between the Doppler groups at 32 or 34 weeks' gestation. Conclusions An elevated UAD PI at 28 weeks' gestation in the absence of FGR or prematurity is associated with lower scores of declarative memory in children aged 12 years. A potential explanation for this is an element of placental insufficiency in the presence of the appropriately grown fetus, which affects the development of the fetal hippocampus and information processing and memory long-term. These findings, however, had no impact on overall academic ability, mental processing and reasoning or overall behavioural function. PMID:27311899

  10. Low Body Mass Index Is Associated with Increased Risk of Acute GVHD after Umbilical Cord Blood Transplantation in Children and Young Adults with Acute Leukemia: A Study on Behalf of Eurocord and the EBMT Pediatric Disease Working Party.

    PubMed

    Paviglianiti, Annalisa; Dalle, Jean Hugues; Ayas, Mouhab; Boelens, Jan Jaap; Volt, Fernanda; Iori, Anna Paola; de Souza, Mair Pedro; Diaz, Miguel Angel; Michel, Gerard; Locatelli, Franco; Jubert, Charlotte; Yakoub-Agha, Ibrahim; Bittencourt, Henrique; Bertrand, Yves; Kenzey, Chantal; Tozatto Maio, Karina; Hayashi, Hiromi; Rocha, Vanderson; Bader, Peter; Gluckman, Eliane; Ruggeri, Annalisa

    2018-04-01

    Body mass index (BMI) may influence outcomes after allogeneic hematopoietic stem cell transplantation (HSCT). However, the impact of BMI on survival in children undergoing HSCT is not well defined, with conflicting results being reported on this issue. We analyzed 855 patients age 2 to 20 years with diagnosis of acute leukemia who underwent umbilical cord blood transplantation (UCBT) from 1990 to 2015. Patients were classified according to BMI as normal (fifth to 85th percentile), underweight (less than fifth percentile), overweight (85th to 95th percentile), and obese (>95th percentile) using growth charts for age and sex. All patients received single-unit UCBT after a myeloablative conditioning regimen. Diagnosis was acute lymphoblastic leukemia in 68% of the patients. Sixty-one percent of patients (n = 523) were in the normal BMI category, 11% (n = 96) were underweight, 16% (n = 137) overweight, and 12% (n = 99) obese. The cumulative incidence of grade II to IV acute graft-versus-host disease (aGVHD) was 35% (32% to 38%). According to pretransplantation BMI, aGVHD was 46% (33% to 59%) for underweight, 34% (31% to 42%) for normal, 36% (18% to 38%) for overweight, and 27% (15% to 37%) for obese (P = .04). In multivariate analysis, a BMI less than the fifth percentile was associated with higher incidence of acute grade II to IV GVHD compared with normal-BMI patients (hazard ratio,  1.61; 95% confidence interval, 1.15 to 2.26; P = .006). Our results show that being underweight at the time of transplantation is associated with an increased risk of aGVHD, highlighting the importance of nutritional status before UCBT. Copyright © 2017 The American Society for Blood and Marrow Transplantation. Published by Elsevier Inc. All rights reserved.

  11. Lipids and leukocytes in newborn umbilical vein blood, birth weight and maternal body mass index.

    PubMed

    Brittos, T; de Souza, W B; Anschau, F; Pellanda, L

    2016-12-01

    Maternal obesity during pregnancy may influence fetal development and possibly predispose offspring to cardiovascular disease. The aim of the present study was to evaluate the relationship between maternal pre-pregnancy body mass index (BMI) and weight gain during pregnancy, and newborn birth weight, with lipid profile, high-sensitivity C-reactive protein (hs-CRP) and leukocyte in newborns. We performed a cross-sectional study of 245 mothers and their children. Blood was collected from the umbilical vein and assayed for lipid profile, hs-CRP and leukocyte count. Newborns average weight was 3241 g, total cholesterol 53.9 mg/dl, high-density lipoprotein cholesterol (HDL-c) 21.9 mg/dl, low-density lipoprotein cholesterol (LDL-c) 26.2 mg/dl, triglyceride 29.5 mg/dl and leukocytes 13,777/mm3. There was a direct correlation of pre-pregnancy BMI of overweight mothers with total cholesterol (r=0.220, P=0.037) and LDL-c (r=0.268, P=0.011) of newborns. Total cholesterol, LDL-c and HDL-c were higher in pre-term newborns (66.3±19.7, 35.9±14.6 and 25.2±7.7 mg/dl, respectively) that in full-term (52.4±13.1, 25.0±8.7 and 21.5±6.0 mg/dl), with P=0.001, 0.001 and 0.003, respectively. Leukocyte counts were higher in full-term newborns (14,268±3982/mm3) compared with pre-term (9792±2836/mm3, P<0.0001). There was a direct correlation between birth weight and leukocyte counts of newborns (r=0.282, P<0.0001). These results suggest the possible interaction of maternal weight and fetal growth with lipid metabolism and leukocyte count in the newborn, which may be linked to programming of the immune system.

  12. Neonatal atrial flutter after insertion of an intracardiac umbilical venous catheter

    PubMed Central

    de Almeida, Marcos Moura; Tavares, Wládia Gislaynne de Sousa; Furtado, Maria Mônica Alencar Araripe; Fontenele, Maria Marcia Farias Trajano

    2016-01-01

    Abstract Objective: To describe a case of neonatal atrial flutter after the insertion of an intracardiac umbilical venous catheter, reporting the clinical presentation and reviewing the literature on this subject. Case description: A late-preterm newborn, born at 35 weeks of gestational age to a diabetic mother and large for gestational age, with respiratory distress and rule-out sepsis, required an umbilical venous access. After the insertion of the umbilical venous catheter, the patient presented with tachycardia. Chest radiography showed that the catheter was placed in the position that corresponds to the left atrium, and traction was applied. The patient persisted with tachycardia, and an electrocardiogram showed atrial flutter. As the patient was hemodynamically unstable, electric cardioversion was successfully applied. Comments: The association between atrial arrhythmias and misplaced umbilical catheters has been described in the literature, but in this case, it is noteworthy that the patient was an infant born to a diabetic mother, which consists in another risk factor for heart arrhythmias. Isolated atrial flutter is a rare tachyarrhythmia in the neonatal period and its identification is essential to establish early treatment and prevent systemic complications and even death. PMID:26525686

  13. Concentrations of pentosidine, an advanced glycation end-product, in umbilical cord blood.

    PubMed

    Tsukahara, Hirokazu; Ohta, Naoko; Sato, Shuko; Hiraoka, Masahiro; Shukunami, Ken-Ichi; Uchiyama, Mayumi; Kawakami, Hisako; Sekine, Kyouichi; Mayumi, Mitsufumi

    2004-07-01

    Advanced glycation end-products (AGEs) are formed over several weeks to months by non-enzymatic glycation and oxidation ("glycoxidation") reactions between carbohydrate-derived carbonyl groups and protein amino groups, known as the Maillard reaction. Pentosidine is one of the best-characterized AGEs and is accepted as a satisfactory marker for glycoxidation in vivo. The present study was intended to measure pentosidine concentrations in umbilical cord blood from newborns with various gestational ages using our recently established high-performance liquid chromatography method [Tsukahara, H. et al. (2003) Pediatr. Res. 54, 419-424]. Our study demonstrates, for the first time, that pentosidine is detected in most of the umbilical blood samples. This study also shows that the umbilical blood concentrations of pentosidine are considerably lower than normal adult values, but that they increase with gestation progression and fetal growth. Umbilical pentosidine concentrations were significantly elevated in newborns of mothers with preeclampsia compared to those of mothers without preeclampsia. We conclude that accumulation of AGEs and oxidative stress occurs in fetal tissues and organs in utero at the early stage of human life and that their accumulation is augmented in the maternal preeclampsic condition.

  14. A Review of Factors Influencing the Banking of Collected Umbilical Cord Blood Units

    PubMed Central

    Allan, David; Petraszko, Tanya; Elmoazzen, Heidi; Smith, Susan

    2013-01-01

    Umbilical cord blood banking efforts have increased dramatically in the past two decades in response to increasing demand for alternative sources of blood stem cells to support patients requiring hematopoietic stem cell transplantation. Transplant centres have accumulated increasing expertise in their understanding of umbilical cord blood characteristics that are associated with improved outcome following transplantation. These characteristics and factors can assist transplant centres in selecting cord blood units from the worldwide inventory of banked units. Umbilical cord blood banks, therefore, need to remain agile in adjusting the inventory of the banks to address shifts or changes in the needs of transplant centres. Public umbilical cord blood banks face the challenge of building inventory while managing limited resources and are faced with decisions regarding which units can be stored and which units that have been collected should be discarded or used for other endeavours such as research. To this end, we sought to review parameters influencing the decision to bank a collected cord blood unit. In this paper, we will address parameters associated with graft potency and address other factors that guide the decision to bank collected units. PMID:23533442

  15. Experimental studies on the tensile properties of human umbilical cords.

    PubMed

    Tantius, Britta; Rothschild, Markus A; Valter, Markus; Michael, Joern; Banaschak, Sibylle

    2014-03-01

    When tried in court, mothers accused of neonaticide may claim that the umbilical cord just broke during birth and the newborn child bled to death accordingly. To evaluate the possibility of a breakage of the umbilical cord is the goal of this work. Therefore 25 umbilical cords from neonates of both sexes born at term were stretched using an electrically operated material testing machine and the energy necessary to break them was measured. This experimental set-up equals a static strain, not a dynamic one. The maximum force endured (F max) ranged from 37.24 N to 150.04 N. The average force endured was 79.87 N with a standard deviation of 27.39. The elongation at break varied from 13.24% to a maximum of 119.93%. We found no relationship between the force endured and any of the following parameters: birth weight, pH of the venous umbilical blood, diameter of cord, free length under testing, duration of pregnancy or the mother's age. We performed a literature research and tried to define the circumstances in which a break is more likely to occur, these being malformations, entanglement or disease, e.g. inflammation. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  16. How does tobacco smoke influence the morphometry of the fetus and the umbilical cord?-Research on pregnant women with intrauterine growth restriction exposed to tobacco smoke.

    PubMed

    Milnerowicz-Nabzdyk, Ewa; Bizoń, Anna

    2015-12-01

    Proper structure of the umbilical cord is important for the fetal development. We evaluated effects of toxic factors from tobacco smoke on fetal and umbilical cord morphometry. 109 women in weeks 29-40 of pregnancy (31 smokers with intrauterine growth restriction (IUGR); 28 non-smoking women with IUGR; 50 healthy pregnancies) were included. In smokers with IUGR, cotinine, cadmium and lead concentrations were significantly higher than in controls (mean 55.23ng/l; 1.52ng/ml; 14.85ng/ml vs 1.07; 0.34; 9.42) and inverse correlation between lead concentration and uncoiled umbilical cord was significant (r=-0.80). In smokers with IUGR, area of Wharton's jelly was increased compared to nonsmokers and controls. Inverse correlations occurred between cotinine and cadmium concentration and fetal percentile in smokers (r=-0.87; r=-0.87) and non-smokers (r=-0.47; r=-0.78) with IUGR. Exposure to tobacco smoke measured by cotinine, cadmium and lead concentration has an impact on fetal growth and umbilical cord morphometry and correlates with intensity of IUGR. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Four signature motifs define the first class of structurally related large coiled-coil proteins in plants.

    PubMed Central

    Gindullis, Frank; Rose, Annkatrin; Patel, Shalaka; Meier, Iris

    2002-01-01

    Background Animal and yeast proteins containing long coiled-coil domains are involved in attaching other proteins to the large, solid-state components of the cell. One subgroup of long coiled-coil proteins are the nuclear lamins, which are involved in attaching chromatin to the nuclear envelope and have recently been implicated in inherited human diseases. In contrast to other eukaryotes, long coiled-coil proteins have been barely investigated in plants. Results We have searched the completed Arabidopsis genome and have identified a family of structurally related long coiled-coil proteins. Filament-like plant proteins (FPP) were identified by sequence similarity to a tomato cDNA that encodes a coiled-coil protein which interacts with the nuclear envelope-associated protein, MAF1. The FPP family is defined by four novel unique sequence motifs and by two clusters of long coiled-coil domains separated by a non-coiled-coil linker. All family members are expressed in a variety of Arabidopsis tissues. A homolog sharing the structural features was identified in the monocot rice, indicating conservation among angiosperms. Conclusion Except for myosins, this is the first characterization of a family of long coiled-coil proteins in plants. The tomato homolog of the FPP family binds in a yeast two-hybrid assay to a nuclear envelope-associated protein. This might suggest that FPP family members function in nuclear envelope biology. Because the full Arabidopsis genome does not appear to contain genes for lamins, it is of interest to investigate other long coiled-coil proteins, which might functionally replace lamins in the plant kingdom. PMID:11972898

  18. A new twist in the coil: functions of the coiled-coil domain of structural maintenance of chromosome (SMC) proteins.

    PubMed

    Matityahu, Avi; Onn, Itay

    2018-02-01

    The higher-order organization of chromosomes ensures their stability and functionality. However, the molecular mechanism by which higher order structure is established is poorly understood. Dissecting the activity of the relevant proteins provides information essential for achieving a comprehensive understanding of chromosome structure. Proteins of the structural maintenance of chromosome (SMC) family of ATPases are the core of evolutionary conserved complexes. SMC complexes are involved in regulating genome dynamics and in maintaining genome stability. The structure of all SMC proteins resembles an elongated rod that contains a central coiled-coil domain, a common protein structural motif in which two α-helices twist together. In recent years, the imperative role of the coiled-coil domain to SMC protein activity and regulation has become evident. Here, we discuss recent advances in the function of the SMC coiled coils. We describe the structure of the coiled-coil domain of SMC proteins, modifications and interactions that are mediated by it. Furthermore, we assess the role of the coiled-coil domain in conformational switches of SMC proteins, and in determining the architecture of the SMC dimer. Finally, we review the interplay between mutations in the coiled-coil domain and human disorders. We suggest that distinctive properties of coiled coils of different SMC proteins contribute to their distinct functions. The discussion clarifies the mechanisms underlying the activity of SMC proteins, and advocates future studies to elucidate the function of the SMC coiled coil domain.

  19. RF Magnetic Field Uniformity of Rectangular Planar Coils for Resonance Imaging

    DTIC Science & Technology

    2016-02-04

    coil with square -shaped overlapping turns along the 135mm length of the coil. This paper compares these two coils to determine which has a more...in which, the coil arrays consist of a few square or circular coils side-by-side or overlapping. Mobile unilateral NMR/MRI scanners were...magnetic field along the length of a normal rectangular coil (NRC) and a rectangular coil with overlapping square -shaped turns (RCOS). The RCOS coil is

  20. Testing of the X-33 umbilical system at KSC

    NASA Technical Reports Server (NTRS)

    1999-01-01

    At the Launch Equipment Test Facility, Mike Solomon, with Lockheed Martin Technical Operations, studies a part of the X-33 umbilical system during testing. Pointing to the part is Will Reaves, also with Lockheed Martin Technical Operations. A team of Kennedy Space Center experts developed the umbilical system, comprising panels, valves and hoses that provide the means to load the X-33 with super-cold propellant. The X-33, under construction at Lockheed Martin Skunk Works in Palmdale, Calif., is a half-scale prototype of the planned operational reusable launch vehicle dubbed VentureStar.

  1. Umbilical cord blood banking and the next generation of human tissue regulation: an agenda for research.

    PubMed

    Stewart, Cameron; Kerridge, Ian

    2012-03-01

    The transformation of umbilical cord blood from being a waste product to being a valuable source of stem cells has led to the emergence of significant legal, ethical and social issues. This editorial proposes an agenda for research into the regulation of umbilical cord blood banking which focuses on issues of characterisation, consent, the interplay of public and private services, and the importance of applying property concepts. It concludes by stressing the need for reform to be based on well-informed public debate.

  2. Introduction to the Portable Life Support Schematic and Technology Development Components

    NASA Technical Reports Server (NTRS)

    Conger, Bruce

    2008-01-01

    Conger presented the operations and functions of the baseline Constellation Program (CxP) Portable Life Support System (PLSS) schematic and key development technologies. He explained the functional descriptions of the schematic components in the fluid systems of the PLSS for multiple operational scenarios. PLSS subsystems include the oxygen subsystem, the ventilation subsystem, and the thermal subsystem. He also presented the operational PLSS modes: Nominal EVA mode, Umbilical - no recharge mode, Umbilical - with recharge mode, BENDS mode, BUDDY mode, Secondary oxygen mode, and the PLSS-removed umbilical mode.

  3. Testing of the X-33 umbilical system at KSC

    NASA Technical Reports Server (NTRS)

    1999-01-01

    At the Launch Equipment Test Facility, Mike Solomon (left) and Will Reaves (right), both with Lockheed Martin Technical Operations, move in for a close look at part of the X-33 umbilical system. A team of Kennedy Space Center experts developed the umbilical system, comprising panels, valves and hoses that provide the means to load the X-33 with super-cold propellant. The X-33, under construction at Lockheed Martin Skunk Works in Palmdale, Calif., is a half-scale prototype of the planned operational reusable launch vehicle dubbed VentureStar.

  4. Incarceration of umbilical hernia: a rare complication of large volume paracentesis.

    PubMed

    Khodarahmi, Iman; Shahid, Muhammad Usman; Contractor, Sohail

    2015-09-01

    We present two cases of umbilical hernia incarceration following large volume paracentesis (LVP) in patients with cirrhotic ascites. Both patients became symptomatic within 48 hours after the LVP. Although being rare, given the significantly higher mortality rate of cirrhotic patients undergoing emergent herniorrhaphy, this complication of LVP is potentially serious. Therefore, it is recommended that patients be examined closely for the presence of umbilical hernias before removal of ascitic fluid and an attempt should be made for external reduction of easily reducible hernias, if a hernia is present.

  5. Incarceration of umbilical hernia: a rare complication of large volume paracentesis

    PubMed Central

    Khodarahmi, Iman; Shahid, Muhammad Usman; Contractor, Sohail

    2015-01-01

    We present two cases of umbilical hernia incarceration following large volume paracentesis (LVP) in patients with cirrhotic ascites. Both patients became symptomatic within 48 hours after the LVP. Although being rare, given the significantly higher mortality rate of cirrhotic patients undergoing emergent herniorrhaphy, this complication of LVP is potentially serious. Therefore, it is recommended that patients be examined closely for the presence of umbilical hernias before removal of ascitic fluid and an attempt should be made for external reduction of easily reducible hernias, if a hernia is present. PMID:26629305

  6. Experimental measurement of coil-rod-coil block copolymer tracer diffusion through entangled coil homopolymers

    PubMed Central

    Wang, Muzhou; Timachova, Ksenia; Olsen, Bradley D.

    2014-01-01

    The diffusion of coil-rod-coil triblock copolymers in entangled coil homopolymers is experimentally measured and demonstrated to be significantly slower than rod or coil homopolymers of the same molecular weight. A model coil-rod-coil triblock was prepared by expressing rodlike alanine-rich α-helical polypeptides in E. coli and conjugating coillike poly(ethylene oxide) (PEO) to both ends to form coil-rod-coil triblock copolymers. Tracer diffusion through entangled PEO homopolymer melts was measured using forced Rayleigh scattering at various rod lengths, coil molecular weights, and coil homopolymer concentrations. For rod lengths, L, that are close to the entanglementh length, a, the ratio between triblock diffusivity and coil homopolymer diffusivity decreases monotonically and is only a function of L/a, in quantitative agreement with previous simulation results. For large rod lengths, diffusion follows an arm retraction scaling, which is also consistent with previous theoretical predictions. These experimental results support the key predictions of theory and simulation, suggesting that the mismatch in curvature between rod and coil entanglement tubes leads to the observed diffusional slowing. PMID:25484454

  7. Magnetic propulsion of a magnetic device using three square-Helmholtz coils and a square-Maxwell coil.

    PubMed

    Ha, Yong H; Han, Byung H; Lee, Soo Y

    2010-02-01

    We introduce a square coil system for remote magnetic navigation of a magnetic device without any physical movements of the coils. We used three square-Helmholtz coils and a square-Maxwell coil for magnetic propulsion of a small magnet along the desired path. All the square coils are mountable on a cubic frame that has an opening to accommodate a living subject. The square-Helmholtz coils control the magnetic propulsion direction by generating uniform magnetic field along the desired direction while the square-Maxwell coil controls the propulsion force by generating magnetic gradient field. We performed magnetic propulsion experiments with a down-scaled coil set and a three-channel coil driver. Experimental results demonstrate that we can use the square coil set for magnetic navigation of a magnetic device without any physical movements of the coils.

  8. Early Cord Metabolite Index and Outcome in Perinatal Asphyxia and Hypoxic-Ischaemic Encephalopathy.

    PubMed

    Ahearne, C E; Denihan, N M; Walsh, B H; Reinke, S N; Kenny, L C; Boylan, G B; Broadhurst, D I; Murray, D M

    2016-01-01

    A 1H-NMR-derived metabolomic index based on early umbilical cord blood alterations of succinate, glycerol, 3-hydroxybutyrate and O-phosphocholine has shown potential for the prediction of hypoxic-ischaemic encephalopathy (HIE) severity. To evaluate whether this metabolite score can predict 3-year neurodevelopmental outcome in infants with perinatal asphyxia and HIE, compared with current standard biochemical and clinical markers. From September 2009 to June 2011, infants at risk of perinatal asphyxia were recruited from a single maternity hospital. Cord blood was drawn and biobanked at delivery. Neonates were monitored for development of encephalopathy both clinically and electrographically. Neurodevelopmental outcome was assessed at 36-42 months using the Bayley Scales of Infant and Toddler Development, ed. III (BSID-III). Death and cerebral palsy were also considered as abnormal end points. Thirty-one infants had both metabolomic analysis and neurodevelopmental outcome at 36-42 months. No child had a severely abnormal BSID-III result. The metabolite index significantly correlated with outcome (ρ2 = 0.30, p < 0.01), which is robust to predict both severe outcome (area under the receiver operating characteristic curve: 0.92, p < 0.01) and intact survival (0.80, p = 0.01). There was no correlation between the index score and performance in the individual BSID-III subscales (cognitive, language, motor). The metabolite index outperformed other standard biochemical markers at birth for prediction of outcome at 3 years, but was not superior to EEG or the Sarnat score. © 2016 S. Karger AG, Basel.

  9. Newborn umbilical cord and skin care in Sylhet District, Bangladesh: Implications for promotion of umbilical cord cleansing with topical chlorhexidine

    PubMed Central

    Alam, Ashraful; Ali, Nabeel Ashraf; Sultana, Nighat; Mullany, Luke C.; Teela, Katherine C.; Khan, Nazib Uz Zaman; Baqui, Abdullah H.; Arifeen, Shams El; Mannan, Ishtiaq; Darmstadt, Gary L.; Winch, Peter J.

    2010-01-01

    Background Newborn cord care practices may directly contribute to infections, which account for a large proportion of the 4 million annual global neonatal deaths. This formative research study assessed current umbilical and skin care knowledge and practices for neonates in Sylhet, Bangladesh in preparation for a cluster-randomised trial of the impact of topical chlorhexidine cord cleansing on neonatal mortality and omphalitis. Methodology Unstructured interviews (n=60), structured observations (n=20), rating and ranking exercises (n=40), and household surveys (n=400) were conducted to elicit specific behaviours regarding newborn cord and skin care practices. These included hand-washing, skin and cord care at the time of birth, persons engaged in cord care, cord cutting practices, topical applications to the cord at the time of birth, wrapping/dressing of the cord stump, and use of skin-to-skin care. Results Ninety percent of deliveries occurred at home. The umbilical cord was almost always (98%) cut after delivery of the placenta, and cut by mothers in more than half the cases (57%). Substances were commonly (52%) applied to the stump after cord cutting; turmeric was the most common application (83%). Umbilical stump care revolved around bathing, skin massage with mustard oil, and heat massage on the umbilical stump. Forty-two percent of newborns were bathed on the day of birth. Mothers were the principal provider for skin and cord care during the neonatal period and 9% reported umbilical infections in their infants. Discussion Unhygienic cord care practices are prevalent in the study area. Efforts to promote hand washing, cord cutting with clean instruments, and avoiding unclean home applications to the cord may reduce exposure and improve neonatal outcomes. Such efforts should broadly target a range of caregivers, including mothers and other female household members. PMID:19057570

  10. Local Perceptions, Cultural Beliefs and Practices That Shape Umbilical Cord Care: A Qualitative Study in Southern Province, Zambia

    PubMed Central

    Herlihy, Julie M.; Shaikh, Affan; Mazimba, Arthur; Gagne, Natalie; Grogan, Caroline; Mpamba, Chipo; Sooli, Bernadine; Simamvwa, Grace; Mabeta, Catherine; Shankoti, Peggy; Messersmith, Lisa; Semrau, Katherine; Hamer, Davidson H.

    2013-01-01

    Background Global policy regarding optimal umbilical cord care to prevent neonatal illness is an active discussion among researchers and policy makers. In preparation for a large cluster-randomized control trial to measure the impact of 4% chlorhexidine as an umbilical wash versus dry cord care on neonatal mortality in Southern Province, Zambia, we performed a qualitative study to determine local perceptions of cord health and illness and the cultural belief system that shapes umbilical cord care knowledge, attitudes, and practices. Methods and Findings This study consisted of 36 focus group discussions with breastfeeding mothers, grandmothers, and traditional birth attendants, and 42 in-depth interviews with key community informants. Semi-structured field guides were used to lead discussions and interviews at urban and rural sites. A wide variation in knowledge, beliefs, and practices surrounding cord care was discovered. For home deliveries, cords were cut with non-sterile razor blades or local grass. Cord applications included drying agents (e.g., charcoal, baby powder, dust), lubricating agents (e.g., Vaseline, cooking oil, used motor oil) and agents intended for medicinal/protective purposes (e.g., breast milk, cow dung, chicken feces). Concerns regarding the length of time until cord detachment were universally expressed. Blood clots in the umbilical cord, bulongo-longo, were perceived to foreshadow neonatal illness. Management of bulongo-longo or infected umbilical cords included multiple traditional remedies and treatment at government health centers. Conclusion Umbilical cord care practices and beliefs were diverse. Dry cord care, as recommended by the World Health Organization at the time of the study, is not widely practiced in Southern Province, Zambia. A cultural health systems model that depicts all stakeholders is proposed as an approach for policy makers and program implementers to work synergistically with existing cultural beliefs and practices in order to maximize effectiveness of evidence-based interventions. PMID:24244447

  11. Umbilical Cord Care in the Newborn Infant.

    PubMed

    Stewart, Dan; Benitz, William

    2016-09-01

    Postpartum infections remain a leading cause of neonatal morbidity and mortality worldwide. A high percentage of these infections may stem from bacterial colonization of the umbilicus, because cord care practices vary in reflection of cultural traditions within communities and disparities in health care practices globally. After birth, the devitalized umbilical cord often proves to be an ideal substrate for bacterial growth and also provides direct access to the bloodstream of the neonate. Bacterial colonization of the cord not infrequently leads to omphalitis and associated thrombophlebitis, cellulitis, or necrotizing fasciitis. Various topical substances continue to be used for cord care around the world to mitigate the risk of serious infection. More recently, particularly in high-resource countries, the treatment paradigm has shifted toward dry umbilical cord care. This clinical report reviews the evidence underlying recommendations for care of the umbilical cord in different clinical settings. Copyright © 2016 by the American Academy of Pediatrics.

  12. Endometriosis of umbilical cicatrix: case report and review of the literature.

    PubMed

    Rosina, Paolo; Pugliarello, Silvia; Colato, Chiara; Girolomoni, Giampiero

    2008-01-01

    Umbilical endometriosis has an estimated incidence of 0.5%-1% of all patients with endometrial ectopia. It is a very rare disease, but should be considered on the differential diagnosis of umbilical lesions. We report on a case of spontaneous umbilical endometriosis in a 38-year-old woman, with a dark brown nodule periodically bleeding, associated with severe abdominal pain. There was no history of endometriosis and she had not been pregnant before. Laparoscopic visualization of pelvic cavity showed bilateral ovarian endometrioma (it was removed while sparing the ovaries). Surgical treatment proved effective. Cutaneous endometriosis could be a sign of internal endometriosis. Presentations may be atypical and pose diagnostic difficulty, mimicking other acute diseases, e.g., skin neoplasm, folliculitis, etc., but it should be suspected in any female presenting with a painful or bleeding mass close to the umbilicus or abdominal surgical scar.

  13. Design, Development, And Testing of Umbilical System Mechanisms for the X-33 Advanced Technology Demonstrator

    NASA Technical Reports Server (NTRS)

    Littlefield, Alan C.; Melton, Gregory S.

    2000-01-01

    The X-33 Advanced Technology Demonstrator is an un-piloted, vertical take-off, horizontal landing spacecraft. The purpose of the X-33 program is to demonstrate technologies that will dramatically lower the cost of access to space. The rocket-powered X-33 will reach an altitude of up to 100 km and speeds between Mach 13 and 15. Fifteen flight tests are planned, beginning in 2000. Some of the key technologies demonstrated will be the linear aerospike engine, improved thermal protection systems, composite fuel tanks and reduced operational timelines. The X-33 vehicle umbilical connections provide monitoring, power, cooling, purge, and fueling capability during horizontal processing and vertical launch operations. Two "rise-off" umbilicals for the X-33 have been developed, tested, and installed. The X-33 umbilical systems mechanisms incorporate several unique design features to simplify horizontal operations and provide reliable disconnect during launch.

  14. Design, Development,and Testing of Umbillical System Mechanisms for the X-33 Advanced Technology Demonstrator

    NASA Technical Reports Server (NTRS)

    Littlefield, Alan C.; Melton, Gregory S.

    1999-01-01

    The X-33 Advanced Technology Demonstrator is an un-piloted, vertical take-off, horizontal landing spacecraft. The purpose of the X-33 program is to demonstrate technologies that will dramatically lower the cost of access to space. The rocket-powered X-33 will reach an altitude of up to 100 km and speeds between Mach 13 and 15. Fifteen flight tests are planned, beginning in 2000. Some of the key technologies demonstrated will be the linear aerospike engine, improved thermal protection systems, composite fuel tanks and reduced operational timelines. The X-33 vehicle umbilical connections provide monitoring, power, cooling, purge, and fueling capability during horizontal processing and vertical launch operations. Two "rise-ofF' umbilicals for the X-33 have been developed, tested, and installed. The X-33 umbilical systems mechanisms incorporate several unique design features to simplify horizontal operations and provide reliable disconnect during launch.

  15. Study on electromagnetic characteristics of the magnetic coupling resonant coil for the wireless power transmission system.

    PubMed

    Wang, Zhongxian; Liu, Yiping; Wei, Yonggeng; Song, Yilin

    2018-01-01

    The resonant coil design is taken as the core technology in the magnetic coupling resonant wireless power transmission system, which achieves energy transmission by the coupling of the resonant coil. This paper studies the effect of the resonant coil on energy transmission and the efficiency of the system. Combining a two-coil with a three-coil system, the optimum design method for the resonant coil is given to propose a novel coil structure. First, the co-simulation methods of Pspice and Maxwell are used. When the coupling coefficient of the resonant coil is different, the relationship between system transmission efficiency, output power, and frequency is analyzed. When the self-inductance of the resonant coil is different, the relationship between the performance and frequency of the system transmission is analyzed. Then, two-coil and three-coil structure models are built, and the parameters of the magnetic field of the coils are calculated and analyzed using the finite element method. In the end, a dual E-type simulation circuit model is used to optimize the design of the novel resonance coil. The co-simulation results show that the coupling coefficients of the two-coil, three-coil, and novel coil systems are 0.017, 0.17 and 0.0126, respectively. The power loss of the novel coil is 16.4 mW. There is an obvious improvement in the three-coil system, which shows that the magnetic leakage of the field and the energy coupling are relatively small. The new structure coil has better performance, and the load loss is lower; it can improve the system output power and transmission efficiency.

  16. Applying graph theory to protein structures: an atlas of coiled coils.

    PubMed

    Heal, Jack W; Bartlett, Gail J; Wood, Christopher W; Thomson, Andrew R; Woolfson, Derek N

    2018-05-02

    To understand protein structure, folding and function fully and to design proteins de novo reliably, we must learn from natural protein structures that have been characterised experimentally. The number of protein structures available is large and growing exponentially, which makes this task challenging. Indeed, computational resources are becoming increasingly important for classifying and analysing this resource. Here, we use tools from graph theory to define an atlas classification scheme for automatically categorising certain protein substructures. Focusing on the α-helical coiled coils, which are ubiquitous protein-structure and protein-protein interaction motifs, we present a suite of computational resources designed for analysing these assemblies. iSOCKET enables interactive analysis of side-chain packing within proteins to identify coiled coils automatically and with considerable user control. Applying a graph theory-based atlas classification scheme to structures identified by iSOCKET gives the Atlas of Coiled Coils, a fully automated, updated overview of extant coiled coils. The utility of this approach is illustrated with the first formal classification of an emerging subclass of coiled coils called α-helical barrels. Furthermore, in the Atlas, the known coiled-coil universe is presented alongside a partial enumeration of the 'dark matter' of coiled-coil structures; i.e., those coiled-coil architectures that are theoretically possible but have not been observed to date, and thus present defined targets for protein design. iSOCKET is available as part of the open-source GitHub repository associated with this work (https://github.com/woolfson-group/isocket). This repository also contains all the data generated when classifying the protein graphs. The Atlas of Coiled Coils is available at: http://coiledcoils.chm.bris.ac.uk/atlas/app.

  17. Crystal structure of a super leucine zipper, an extended two-stranded super long coiled coil

    PubMed Central

    Diao, Jiasheng

    2010-01-01

    Coiled coil is a ubiquitous structural motif in proteins, with two to seven alpha helices coiled together like the strands of a rope, and coiled coil folding and assembly is not completely understood. A GCN4 leucine zipper mutant with four mutations of K3A, D7A, Y17W, and H18N has been designed, and the crystal structure has been determined at 1.6 Å resolution. The peptide monomer shows a helix trunk with short curved N- and C-termini. In the crystal, two monomers cross in 35° and form an X-shaped dimer, and each X-shaped dimer is welded into the next one through sticky hydrophobic ends, thus forming an extended two-stranded, parallel, super long coiled coil rather than a discrete, two-helix coiled coil of the wild-type GCN4 leucine zipper. Leucine residues appear at every seventh position in the super long coiled coil, suggesting that it is an extended super leucine zipper. Compared to the wild-type leucine zipper, the N-terminus of the mutant has a dramatic conformational change and the C-terminus has one more residue Glu 32 determined. The mutant X-shaped dimer has a large crossing angle of 35° instead of 18° in the wild-type dimer. The results show a novel assembly mode and oligomeric state of coiled coil, and demonstrate that mutations may affect folding and assembly of the overall coiled coil. Analysis of the formation mechanism of the super long coiled coil may help understand and design self-assembling protein fibers. PMID:20027625

  18. Microcoil embolization during abdominal vascular interventions through microcatheters with a tip of 2 French or less.

    PubMed

    Miyayama, Shiro; Yamashiro, Masashi; Hattori, Yuki; Orito, Nobuaki; Matsui, Ken; Tsuji, Kazunobu; Yoshida, Miki; Matsui, Osamu

    2011-05-01

    The aim of this study was to evaluate the technical aspects of embolization using microcoils through a microcatheter with a tip of 2F or smaller during abdominal vascular interventions. Coil embolization through a microcatheter with a tip of 2F or smaller was attempted in 73 procedures. Two types of microcoil-Liquid Coil (Boston Scientific, Watertown, MA, USA) and Tornado Coil (Cook, Bloomington, IN, USA)-were deployed through four types of thinner microcatheter [2F tip (n = 49) and 1.8F tip (n = 24)]. Coil jams in the microcatheter and coil migration were evaluated. In total, 286 microcoils were placed (mean ± SD, 3.9 ± 4.3 coils per procedure, range 1-32 coils). In 19 procedures (26.9%), Liquid Coils were used alone. In 44 (60.3%), Tornado Coils were used alone. In 10 (13.7%), Liquid Coils and Tornado Coils were combined. There were no coil jams in the microcatheter in this series. One Tornado Coil (0.3%) delivered into the gastroduodenal artery migrated to the right hepatic artery. Liquid Coils and Tornado Coils can be placed through a thinner microcatheter without difficulty. However, there is a risk of coil migration in large vessels or at the proximal site because the catheter tip is not stabilized.

  19. Regulation of malonyl-CoA-acyl carrier protein transacylase network in umbilical cord blood affected by intrauterine hyperglycemia

    PubMed Central

    Zhang, Yong; Ye, Jianping; Fan, Jianxia

    2017-01-01

    Background Gestational diabetes mellitus (GDM) has been shown to be associated with high risk of diabetes in offspring. However, the mechanisms involved in the insulin resistance in offspring are still unclear. Mitochondrial dysfunction is related with insulin resistance. In mitochondria, malonyl-CoA-acyl carrier protein transacylase (MCAT) is the key enzyme of mitochondrial fatty acid synthesis and is estimated to contribute to insulin resistance. In this study, we aimed to examine the role of MCAT and its network in the umbilical cord blood in GDM-induced offspring insulin resistance. Methods We isolated lymphocytes from umbilical cord vein blood in 6 GDM patients and 6 controls and examined the differences of RNA by RNA sequencing. qRT-PCR and western blot were used to measure mRNA and protein changes. Bisulfite genomic sequencing PCR was applied to detect DNA methylation. Results We found more than 400 genes were differentially regulated in the lymphocytes of umbilical cord blood from GDM patients and these genes were mainly enriched in immune system and endocrine system, which relate to mitochondrial dysfunction and insulin resistance. MCAT closely related with PTPN1 (Protein Tyrosine Phosphatase, Non-Receptor Type1) and STAT5A (Signal Transducer And Activator of Transcription 5A), which were all increased in umbilical cord blood from GDM patients. Increase in MCAT may be due to decreased MCAT DNA methylation. Conclusion MCAT and its network with PTPN1, STAT5A are regulated in umbilical cord blood affected by maternal intrauterine hyperglycemia. PMID:29088862

  20. [Systematic umbilical cord blood analysis at birth: feasibility and reliability in a French labour ward].

    PubMed

    Ernst, D; Clerc, J; Decullier, E; Gavanier, G; Dupuis, O

    2012-10-01

    At birth, evaluation of neonatal well-being is crucial. It is though important to perform umbilical cord blood gas analysis, and then to analyze the samples. We wanted to establish the feasibility and reliability of systematic umbilical cord blood sampling in a French labour ward. Study of systematic umbilical cord blood gas analysis was realized retrospectively from 1000 consecutive deliveries. We first established the feasibility of the samples. Feasibility was defined by the ratio of complete cord acid-base data on the number of deliveries from alive newborns. Afterwards, we established the reliability on the remaining cord samples. Reliability was the ratio of samples that fulfilled quality criteria defined by Westgate et al. and revised by Kro et al., on the number of complete samples from alive newborns. At last, we looked for factors that would influence these results. The systematic umbilical cord blood sample feasibility reached 91.6%, and the reliability reached 80.7%. About the delivery mode, 38.6% of emergency caesarians (IC 95% [30.8-46.3]; P<0.0001) led to non-valid samples, when only 11.3% of programmed caesarians (IC 95% [4.3-18.2]; P<0.0001) led to non-valid samples. Umbilical cord blood analysis were significantly less validated during emergency caesarians. Realization of systematic cord blood gas analysis was followed by 8.4% of incomplete samples, and by 19.3% that were uninterpretable. Training sessions should be organized to improve the feasibility and reliability, especially during emergency caesarians. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  1. Probabilistic Design Methodology and its Application to the Design of an Umbilical Retract Mechanism

    NASA Technical Reports Server (NTRS)

    Onyebueke, Landon; Ameye, Olusesan

    2002-01-01

    A lot has been learned from past experience with structural and machine element failures. The understanding of failure modes and the application of an appropriate design analysis method can lead to improved structural and machine element safety as well as serviceability. To apply Probabilistic Design Methodology (PDM), all uncertainties are modeled as random variables with selected distribution types, means, and standard deviations. It is quite difficult to achieve a robust design without considering the randomness of the design parameters which is the case in the use of the Deterministic Design Approach. The US Navy has a fleet of submarine-launched ballistic missiles. An umbilical plug joins the missile to the submarine in order to provide electrical and cooling water connections. As the missile leaves the submarine, an umbilical retract mechanism retracts the umbilical plug clear of the advancing missile after disengagement during launch and retrains the plug in the retracted position. The design of the current retract mechanism in use was based on the deterministic approach which puts emphasis on factor of safety. A new umbilical retract mechanism that is simpler in design, lighter in weight, more reliable, easier to adjust, and more cost effective has become desirable since this will increase the performance and efficiency of the system. This paper reports on a recent project performed at Tennessee State University for the US Navy that involved the application of PDM to the design of an umbilical retract mechanism. This paper demonstrates how the use of PDM lead to the minimization of weight and cost, and the maximization of reliability and performance.

  2. Comparison between open and closed methods of herniorrhaphy in calves affected with umbilical hernia

    PubMed Central

    Hossain, Mohammad Farhad; Das, Bhajan Chandra; Kim, Gonhyung; Hossain, Mohammad Alamgir

    2009-01-01

    Umbilical hernias in calves commonly present to veterinary clinics, which are normally secondary to failure of the normal closure of the umbilical ring, and which result in the protrusion of abdominal contents into the overlying subcutis. The aim of this study was to compare the suitability of commonly-used herniorrhaphies for the treatment of reducible umbilical hernia in calves. Thirty-four clinical cases presenting to the Veterinary Teaching Hospital, Chittagong Veterinary and Animal Sciences University, Chittagong, Bangladesh from July 2004 to July 2007 were subjected to comprehensive study including history, classification of hernias, size of the hernial rings, presence of adhesion with the hernial sacs, postoperative care and follow-up. They were reducible, non-painful and had no evidence of infection present on palpation. The results revealed a gender influence, with the incidence of umbilical hernia being higher in female calves than in males. Out of the 34 clinical cases, 14 were treated by open method of herniorrhaphy and 20 were treated by closed method. Complications of hernia were higher (21%) in open method-treated cases than in closed method-treated cases (5%). Hernia recurred in three calves treated with open herniorrhaphy within 2 weeks of the procedure, with swelling in situ and muscular weakness at the site of operation. Shorter operation time and excellent healing rate (80%) were found in calves treated with closed herniorrhaphy. These findings suggest that the closed herniorrhaphy is better than the commonly-used open method for the correction of reducible umbilical hernia in calves. PMID:19934601

  3. Unraveling double stranded alpha-helical coiled coils: an x-ray diffraction study on hard alpha-keratin fibers.

    PubMed

    Kreplak, L; Doucet, J; Briki, F

    2001-04-15

    Transformations of proteins secondary and tertiary structures are generally studied in globular proteins in solution. In fibrous proteins, such as hard alpha-keratin, that contain long and well-defined double stranded alpha-helical coiled coil domains, such study can be directly done on the native fibrous tissue. In order to assess the structural behavior of the coiled coil domains under an axial mechanical stress, wide angle x-ray scattering and small angle x-ray scattering experiments have been carried out on stretched horse hair fibers at relative humidity around 30%. Our observations of the three major axial spacings as a function of the applied macroscopic strain have shown two rates. Up to 4% macroscopic strain the coiled coils were slightly distorted but retained their overall conformation. Above 4% the proportion of coiled coil domains progressively decreased. The main and new result of our study is the observation of the transition from alpha-helical coiled coils to disordered chains instead of the alpha-helical coiled coil to beta-sheet transition that occurs in wet fibers.

  4. Development of a planar-type high sensitivity metallic contaminant detector

    NASA Astrophysics Data System (ADS)

    Okabe, Shunsuke; Sasada, Ichiro

    2017-05-01

    Metallic contaminant detectors based on the balanced coil system are widely used in the food industry. In the balanced coil system, an excitation coil and two identical pickup coils are used in a way that the magnetic coupling of pickup coils to the excitation coil is cancelled with each other when no metallic contaminants present. In a conventional system, the excitation coil and the pickup coil are planar and are parallel, therefore the magnetic coupling is strong even if there is no metallic contaminant. Such strong magnetic coupling makes balancing procedure tedious. In this paper, we introduce a new coil system in which pickup coils are set orthogonal to the excitation coil, making the magnetic coupling much small compared to conventional counterpart. Pickup coils are equipped with thin magnetic cores and placed inside the excitation coil being parallel to the excitation coil plane. The balancing method consists of two steps; the one is geometrical and the other is digital processing including down conversion. Experiments are carried out to show the detection capability of ferromagnetic contaminants and non-magnetic contaminants.

  5. Accommodation of structural rearrangements in the huntingtin-interacting protein 1 coiled-coil domain

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wilbur, Jeremy D., E-mail: jwilbur@msg.ucsf.edu; Hwang, Peter K.; Brodsky, Frances M.

    2010-03-01

    Variable packing interaction related to the conformational flexibility within the huntingtin-interacting protein 1 coiled coil domain. Huntingtin-interacting protein 1 (HIP1) is an important link between the actin cytoskeleton and clathrin-mediated endocytosis machinery. HIP1 has also been implicated in the pathogenesis of Huntington’s disease. The binding of HIP1 to actin is regulated through an interaction with clathrin light chain. Clathrin light chain binds to a flexible coiled-coil domain in HIP1 and induces a compact state that is refractory to actin binding. To understand the mechanism of this conformational regulation, a high-resolution crystal structure of a stable fragment from the HIP1 coiled-coilmore » domain was determined. The flexibility of the HIP1 coiled-coil region was evident from its variation from a previously determined structure of a similar region. A hydrogen-bond network and changes in coiled-coil monomer interaction suggest that the HIP1 coiled-coil domain is uniquely suited to allow conformational flexibility.« less

  6. 47. BASE OF UMBILICAL MAST, WITH ELECTRICAL POWER CABLES ON ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    47. BASE OF UMBILICAL MAST, WITH ELECTRICAL POWER CABLES ON LEFT; AIR-CONDITIONER DUCTS ON RIGHT - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 East, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  7. Maternal nutritional status during pregnancy and surma use determine cord lead levels in Karachi, Pakistan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Janjua, Naveed Zafar; Department of Community Health Sciences, Aga Khan University, Karachi; Delzell, Elizabeth

    Objectives: To estimate the umbilical cord blood lead levels (BLLs) of Pakistani neonates and to identify determinants for umbilical BLLs. Methods: We conducted a cross-sectional study of mothers and infants at one of the two obstetric units of two tertiary care hospitals in Karachi during January-August 2005. Information from 540 mothers selected randomly from those registered for delivery was obtained about their pregnancy, diet, and current and past lead exposures. We collected umbilical cord blood for lead levels analyzed using graphite furnace atomic absorption spectrophotometry. We computed geometric and arithmetic means. We performed multiple linear regression analysis to identify factorsmore » associated with log-transformed umbilical cord BLLs. We also performed logistic regression analysis to identify determinants of high lead cord BLLs ({>=}10 {mu}g/dl). Results: The geometric mean cord BLL of the neonates was 9.6 {mu}g/dl; arithmetic mean (S.D.) was 10.8 {mu}g/dl (5.7) with a median of 9.7 {mu}g/dl and a range of 1.8-48.9 {mu}g/dl. Women who reported intake of less than 58.5 mg of elemental iron supplement per day during pregnancy had cord BLL of 10.0 {mu}g/dl; in comparison those women who had higher iron intake had lower cord BLL (8.4 {mu}g/dl). Those who used surma (an eye cosmetic) daily had higher cord BLL (11.5 {mu}g/dl) as compared to those who used it less frequently (9.4 {mu}g/dl). In multivariable linear regression model, higher iron intake, owning a car, and being in 2nd quartile of mid-arm circumference were associated with low lead levels while father's occupation in lead-based industry was associated with significantly higher umbilical cord BLLs. There was interaction of daily surma use and ethnicity. Geometric mean BLLs were varied among surma users by ethnicity. Conclusions: Umbilical cord BLLs are high in Karachi, Pakistan, in comparison to those in developed countries such as United States. Measures are needed to reduce fetal lead exposure to prevent adverse affect on neurocognitive development. Association of low iron (below RDA of 60 mg per day) with high umbilical cord has implications for strengthening iron supplement intake during pregnancy. Umbilical cord BLLs differed among surma users by ethnicity.« less

  8. A prospective study on elective umbilical hernia repair in patients with liver cirrhosis and ascites.

    PubMed

    Eker, Hasan H; van Ramshorst, G H; de Goede, B; Tilanus, H W; Metselaar, H J; de Man, R A; Lange, J F; Kazemier, G

    2011-09-01

    Patients with both cirrhosis and ascites have a 20% risk of developing umbilical hernia. A retrospective study from our center comparing conservative management of umbilical hernia with elective repair in these patients showed a significant risk of mortality as a result of hernia incarceration in conservatively treated patients. The goal of this study was to assess the safety and efficacy of elective umbilical hernia repair in these patients prospectively. Patients with liver cirrhosis and ascites presenting with an umbilical hernia were included in this study. For all patients, the expected time to liver transplantation was more than 3 months, and they did not have a patent umbilical vein in the hernia sac. The following data were collected prospectively for all patients: Child-Pugh-Turcotte (CPT) classification, model for end-stage liver disease (MELD) score, kidney failure, cardiovascular comorbidity, operation-related complications, and duration of hospital stay. Mortality rates were registered in hospital records and verified in government records during follow-up. Mortality rates were registered in hospital records and verified in government records during follow-up. On completion of the study, a retrospective survey was performed to search for any patients who met the study inclusion criteria but were left out of the study cohort. In total, 30 patients (25 males) underwent operation at a mean age of 58 years (standard deviation [SD] ± 9 years). Of these 30 patients, 6 were classified as CPT grade A (20%), 19 (63%) as grade B, and 5 (17%) as grade C. The patients' median MELD score was 12 (interquartile range [IQR], 8-16). In 10 (33%) of the 30 patients hernia repair was performed with mesh. The median duration of hospital stay was 3 days (IQR, 2-4). None of the patients were admitted to the intensive care unit. Postoperative complications included pneumonia and decompensation of cirrhosis (1 case each,) resulting in prolonged hospital stay for those 2 patients. After a median follow-up period of 25 months (IQR, 14-34), 2 (7%) of the 30 patients died; neither of the deaths were attributable to the umbilical hernia repair. A total of 2 patients suffered recurrence. Elective umbilical hernia repair is safe and the preferred approach in cirrhotic patients with ascites. Copyright © 2011 Mosby, Inc. All rights reserved.

  9. Accommodation of structural rearrangements in the huntingtin-interacting protein 1 coiled-coil domain.

    PubMed

    Wilbur, Jeremy D; Hwang, Peter K; Brodsky, Frances M; Fletterick, Robert J

    2010-03-01

    Huntingtin-interacting protein 1 (HIP1) is an important link between the actin cytoskeleton and clathrin-mediated endocytosis machinery. HIP1 has also been implicated in the pathogenesis of Huntington's disease. The binding of HIP1 to actin is regulated through an interaction with clathrin light chain. Clathrin light chain binds to a flexible coiled-coil domain in HIP1 and induces a compact state that is refractory to actin binding. To understand the mechanism of this conformational regulation, a high-resolution crystal structure of a stable fragment from the HIP1 coiled-coil domain was determined. The flexibility of the HIP1 coiled-coil region was evident from its variation from a previously determined structure of a similar region. A hydrogen-bond network and changes in coiled-coil monomer interaction suggest that the HIP1 coiled-coil domain is uniquely suited to allow conformational flexibility.

  10. Crystal Structure of a Super Leucine Zipper an Extended Two-Stranded Super Long Coiled Coil

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    J Diao

    2011-12-31

    Coiled coil is a ubiquitous structural motif in proteins, with two to seven alpha helices coiled together like the strands of a rope, and coiled coil folding and assembly is not completely understood. A GCN4 leucine zipper mutant with four mutations of K3A, D7A, Y17W, and H18N has been designed, and the crystal structure has been determined at 1.6 {angstrom} resolution. The peptide monomer shows a helix trunk with short curved N- and C-termini. In the crystal, two monomers cross in 35{sup o} and form an X-shaped dimer, and each X-shaped dimer is welded into the next one through stickymore » hydrophobic ends, thus forming an extended two-stranded, parallel, super long coiled coil rather than a discrete, two-helix coiled coil of the wild-type GCN4 leucine zipper. Leucine residues appear at every seventh position in the super long coiled coil, suggesting that it is an extended super leucine zipper. Compared to the wild-type leucine zipper, the N-terminus of the mutant has a dramatic conformational change and the C-terminus has one more residue Glu 32 determined. The mutant X-shaped dimer has a large crossing angle of 35{sup o} instead of 18{sup o} in the wild-type dimer. The results show a novel assembly mode and oligomeric state of coiled coil, and demonstrate that mutations may affect folding and assembly of the overall coiled coil. Analysis of the formation mechanism of the super long coiled coil may help understand and design self-assembling protein fibers.« less

  11. System and method for cancelling the effects of stray magnetic fields from the output of a variable reluctance sensor

    DOEpatents

    Chen, Chingchi; Degner, Michael W.

    2002-11-19

    A sensor system for sensing a rotation of a sensing wheel is disclosed. The sensor system has a sensing coil in juxtaposition with the sensing wheel. Moreover, the sensing coil has a sensing coil output signal indicative of the rotational speed of the sensing wheel. Further, a cancellation coil is located remotely from the sensing coil and connected in series therewith. Additionally, the cancellation coil has a cancellation coil output signal indicative of an environmental disturbance which is effecting the sensing coil output signal. The cancellation coil output signal operates to cancel the effects of the environmental disturbance on the sensing coil output signal.

  12. Wellbore manufacturing processes for in situ heat treatment processes

    DOEpatents

    Davidson, Ian Alexander; Geddes, Cameron James; Rudolf, Randall Lynn; Selby, Bruce Allen; MacDonald, Duncan Charles

    2012-12-11

    A method includes making coiled tubing at a coiled tubing manufacturing unit coupled to a coiled tubing transportation system. One or more coiled tubing reels are transported from the coiled tubing manufacturing unit to one or more moveable well drilling systems using the coiled tubing transportation system. The coiled tubing transportation system runs from the tubing manufacturing unit to one or more movable well drilling systems, and then back to the coiled tubing manufacturing unit.

  13. Aneurysm permeability following coil embolization: packing density and coil distribution

    PubMed Central

    Chueh, Ju-Yu; Vedantham, Srinivasan; Wakhloo, Ajay K; Carniato, Sarena L; Puri, Ajit S; Bzura, Conrad; Coffin, Spencer; Bogdanov, Alexei A; Gounis, Matthew J

    2015-01-01

    Background Rates of durable aneurysm occlusion following coil embolization vary widely, and a better understanding of coil mass mechanics is desired. The goal of this study is to evaluate the impact of packing density and coil uniformity on aneurysm permeability. Methods Aneurysm models were coiled using either Guglielmi detachable coils or Target coils. The permeability was assessed by taking the ratio of microspheres passing through the coil mass to those in the working fluid. Aneurysms containing coil masses were sectioned for image analysis to determine surface area fraction and coil uniformity. Results All aneurysms were coiled to a packing density of at least 27%. Packing density, surface area fraction of the dome and neck, and uniformity of the dome were significantly correlated (p<0.05). Hence, multivariate principal components-based partial least squares regression models were used to predict permeability. Similar loading vectors were obtained for packing and uniformity measures. Coil mass permeability was modeled better with the inclusion of packing and uniformity measures of the dome (r2=0.73) than with packing density alone (r2=0.45). The analysis indicates the importance of including a uniformity measure for coil distribution in the dome along with packing measures. Conclusions A densely packed aneurysm with a high degree of coil mass uniformity will reduce permeability. PMID:25031179

  14. 9. DETAIL OF UMBILICAL MAST BASE WITH STEEL STOPS AT ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    9. DETAIL OF UMBILICAL MAST BASE WITH STEEL STOPS AT EAST END OF MOBILE SERVICE STRUCTURE RAIL; VIEW TO NORTHWEST. - Cape Canaveral Air Station, Launch Complex 17, Facility 28501, East end of Lighthouse Road, Cape Canaveral, Brevard County, FL

  15. Sonographic diagnosis of hepatic erosion caused by umbilical catheterization.

    PubMed

    Schiavone, R; Narese, D; Ognibene, N; Rossi, E; Antonello, M; Basile, M; Di Maurizio, M; Defilippi, C

    2016-01-01

    The use of umbilical venous catheter (UVC) is common practice in neonatal units. The traumatic injury of the hepatic parenchyma is a rare complication. We present a case of a preterm newborn underwent ultrasound examination revealing a hyperechogenic focal lesion at the confluence of the hepatic veins This finding, according to patient's history, was suspected to be a traumatic injury of the liver parenchyma caused by umbilical catheterization. During sonographic follow-up this lesion gradually reduced until complete resolution. Finally, when focal hyperechogenic hepatic lesion is incidentally detected in newborn with history of UVC placement, the radiologists must consider the traumatic etiology.

  16. Placental transfer of flunitrazepam following intramuscular administration during labour.

    PubMed Central

    Kanto, J; Erkkola, R; Kangas, L; Pitkänen, Y

    1987-01-01

    After a single intramuscular dose of flunitrazepam 0.015 mg kg-1 (n = 14) in women 37 to 41 weeks pregnant, the concentrations in the umbilical artery and amniotic fluid were significantly lower than in maternal venous plasma. Although the difference between the maternal venous and umbilical venous plasma concentrations was not significant, the mean fetomaternal ratio was 0.7. The plasma protein binding of flunitrazepam was 80 +/- 4% in the mother and 79 +/- 5% in the umbilical circulation. Both mothers and midwives subjectively estimated intramuscular flunitrazepam as a valuable sedative-anxiolytic agent during the first stage of labour. PMID:3580256

  17. Agenesis of the venous duct: two cases of extrahepatic drainage of the umbilical vein and extrahepatic portosystemic shunt with a review of the literature.

    PubMed

    Loomba, Rohit S; Frommelt, Michele; Moe, David; Shillingford, Amanda J

    2015-02-01

    Agenesis of the venous duct is a rare congenital anomaly resulting in abnormal drainage of the umbilical vein into the foetal venous circulation. The clinical presentation and prognosis is variable, and may depend on the specific drainage pathways of the umbilical vein. We present two foetuses with agenesis of the venous duct, both associated with a postnatal portosystemic shunt, but with markedly different postnatal clinical courses. We also review all previously reported cases to better characterise this foetal disorder and the prognosis.

  18. Cure of beta-thalassaemia major by umbilical cord blood transplantation--a case report of Malaysia's first cord blood transplantation.

    PubMed

    Chan, L L; Lin, H P

    1999-08-01

    A 25-month-old boy with beta-thalassaemia major was presented with an opportunity for umbilical cord blood transplantation when his unborn sibling was diagnosed in utero to be a beta-thalassaemia carrier and also human leucocyte antigen compatible. A barely adequate amount of cord blood was collected at the birth of his sibling and infused into the patient after appropriate chemo-conditioning. Engraftment occurred without major complications. The subject is now alive and well 9 months post-transplant, thus marking our first success in umbilical cord blood transplantation.

  19. Differences in twins: the importance of birth order.

    PubMed

    Young, B K; Suidan, J; Antoine, C; Silverman, F; Lustig, I; Wasserman, J

    1985-04-01

    Despite the clinical impression that firstborn twins do better than second-born twins, recent reports have shown no difference in perinatal mortality between them. In order to evaluate differences in twins, more sensitive means than perinatal deaths are necessary. This study examines differences between 80 firstborn and second-born twin pairs with respect to Apgar score, umbilical venous and arterial blood gas, and acid-base data. The umbilical venous and arterial blood PO2, PCO2, base deficit, pH, and lactic acid concentration were measured in paired samples and compared with the paired t test and chi 2 when applicable. Statistically significant differences favoring twin A, the firstborn, were found in 1-minute Apgar score, umbilical venous pH, PO2, and PCO2, and umbilical arterial PO2. The other factors in umbilical venous and arterial blood did not show statistically significant differences. When these parameters were examined with respect to route of delivery, monochorionic and dichorionic twins, interval between twins, and vertex twins only, with the possible effects of malpresentation eliminated, the results persistently favored the firstborn twin. Thus it is unequivocally demonstrated that there are substantial differences at birth favoring the first twin, despite similar perinatal mortality for both. The data suggest that the second-born twin has potentially greater susceptibility to hypoxia and trauma.

  20. Evolution of congenital malformations of the umbilical-portal-hepatic venous system.

    PubMed

    Scalabre, Aurelien; Gorincour, Guillaume; Hery, Geraldine; Gamerre, Marc; Guys, Jean-Michel; de Lagausie, Pascal

    2012-08-01

    The objective of this study is to describe the evolution of 8 cases of congenital malformations of the umbilical-portal-hepatic venous system diagnosed before the first month of life. All cases of congenital malformation of the portal and hepatic venous system diagnosed prenatally or during the first month of life in our institution were systematically reviewed since November 2000. Clinical features, imaging, and anatomical findings were reviewed, focusing primarily on clinical and radiologic evolution. Eight cases of congenital malformation of the umbilical-portal-hepatic venous system were studied. Fifty percent of these malformations were diagnosed prenatally. We report 4 portosystemic shunts. Three involuted spontaneously, and the fourth one required surgical treatment. We report a variation of the usual anatomy of portal and hepatic veins that remained asymptomatic, an aneurysmal dilatation of a vitelline vein causing portal vein thrombosis that needed prompt surgical treatment with good result, a complex portal and hepatic venous malformation treated operatively, and a persistent right umbilical vein that remained asymptomatic. Prenatal diagnosis of malformations of the umbilical-portal-hepatic venous network is uncommon. Little is known about the postnatal prognosis. Clinical, biologic, and radiologic follow-up by ultrasonography is essential to distinguish pathologic situations from normal anatomical variants. Copyright © 2012 Elsevier Inc. All rights reserved.

  1. Delivery route determines the presence of immune complexes on umbilical cord erythrocytes.

    PubMed

    de Lima, Andrés; Franco, Luis C; Sarmiento, Andrés; González, John M

    2017-11-01

    Umbilical cord blood offers a unique opportunity to study the basal level of immunoglobulin complexes. This study aims to determine the presence of immune complexes and complement deposition on erythrocytes from umbilical cord blood from normal, full-term pregnancies. In vitro pre-formed IgA, IgG, and IgM complexes were used as positive control for flow cytometry detection, and for C3d deposition. Blood samples (34) of umbilical cord blood taken from vaginal and cesarean deliveries were tested for the presence of immunoglobulin complexes. Fourteen samples from vaginal deliveries and 20 samples from cesarean deliveries were assessed. IgG and IgM complexes were detected on erythrocytes, whereas no IgA complexes or complement deposition was observed. Interestingly, the percentage of IgG complexes was higher on erythrocytes from vaginal delivery samples compared to those from cesarean deliveries. No other associations between immune complexes and other maternal or newborn variables were found. IgG and IgM complexes seem to be normally present on umbilical cord erythrocytes. Erythrocytes from vaginal deliveries have a higher percentage of IgG complexes present compared to that from cesarean deliveries. Since no C3d activity was detected, these complexes are non-pathological and should be part of the newborn's initial innate immune response.

  2. Clinicopathologic features and surgical management of primary umbilical melanoma: a case series.

    PubMed

    Di Monta, Gianluca; Caracò, Corrado; Marone, Ugo; Grimaldi, Antonio Maria; Anniciello, Anna Maria; Di Marzo, Massimiliano; Simeone, Ester; Mori, Stefano

    2015-04-15

    Primary umbilical melanoma is an uncommon tumor that is poorly described in the medical literature. The umbilical region is a particular anatomic site owing to the presence of embryonal remnants, which can be a potential metastatic pathway, as well as the braided lymphatic network drainage. Hence, primary malignant neoplasms affecting the umbilicus require a different and more radical surgical approach compared with other melanomas. In this report, we describe a series of three patients of Caucasian ethnicity who presented with primary umbilical melanoma at the National Cancer Institute of Naples, Italy. All patients underwent wide excision of the tumor including the underlying peritoneum. No surgical complications, either immediate or delayed, were observed in any of the patients. Sentinel lymph node biopsy was negative in two cases. Two of the patients developed metastatic disease and died after systemic medical therapy. The other patient is currently in follow-up, and remains disease-free after 21 months. The umbilicus has vascular and embryological connections with the underlying peritoneum, so that early visceral involvement is more likely to occur with primary umbilical melanomas. As such, tumor resection including the underlying peritoneum is required to avoid local relapse, whilst sentinel lymph node biopsy appears to be of poor diagnostic value.

  3. Exploring the umbilical and vaginal port during minimally invasive surgery.

    PubMed

    Tinelli, Andrea; Tsin, Daniel A; Forgione, Antonello; Zorron, Ricardo; Dapri, Giovanni; Malvasi, Antonio; Benhidjeb, Tahar; Sparic, Radmila; Nezhat, Farr

    2017-09-01

    This article focuses on the anatomy, literature, and our own experiences in an effort to assist in the decision-making process of choosing between an umbilical or vaginal port. Umbilical access is more familiar to general surgeons; it is thicker than the transvaginal entry, and has more nerve endings and sensory innervations. This combination increases tissue damage and pain in the umbilical port site. The vaginal route requires prophylactic antibiotics, a Foley catheter, and a period of postoperative sexual abstinence. Removal of large specimens is a challenge in traditional laparoscopy. Recently, there has been increased interest in going beyond traditional laparoscopy by using the navel in single-incision and port-reduction techniques. The benefits for removal of surgical specimens by colpotomy are not new. There is increasing interest in techniques that use vaginotomy in multifunctional ways, as described under the names of culdolaparoscopy, minilaparoscopy-assisted natural orifice surgery, and natural orifice transluminal endoscopic surgery. Both the navel and the transvaginal accesses are safe and convenient to use in the hands of experienced laparoscopic surgeons. The umbilical site has been successfully used in laparoscopy as an entry and extraction port. Vaginal entry and extraction is associated with a lower risk of incisional hernias, less postoperative pain, and excellent cosmetic results.

  4. Umbilical hernia following gastroschisis closure: a common event?

    PubMed

    Tullie, L G C; Bough, G M; Shalaby, A; Kiely, E M; Curry, J I; Pierro, A; De Coppi, P; Cross, K M K

    2016-08-01

    To assess incidence and natural history of umbilical hernia following sutured and sutureless gastroschisis closure. With audit approval, we undertook a retrospective clinical record review of all gastroschisis closures in our institution (2007-2013). Patient demographics, gastroschisis closure method and umbilical hernia occurrence were recorded. Data, presented as median (range), underwent appropriate statistical analysis. Fifty-three patients were identified, gestation 36 weeks (31-38), birth weight 2.39 kg (1-3.52) and 23 (43 %) were male. Fourteen patients (26 %) underwent sutureless closure: 12 primary, 2 staged; and 39 (74 %) sutured closure: 19 primary, 20 staged. Sutured closure was interrupted sutures in 24 patients, 11 pursestring and 4 not specified. Fifty patients were followed-up over 53 months (10-101) and 22 (44 %) developed umbilical hernias. There was a significantly greater hernia incidence following sutureless closure (p = 0.0002). In sutured closure, pursestring technique had the highest hernia rate (64 %). Seven patients underwent operative hernia closure; three secondary to another procedure. Seven patients had their hernias resolve. One patient was lost to follow-up and seven remain under observation with no reported complications. There is a significant umbilical hernia incidence following sutureless and pursestring sutured gastroschisis closure. This has not led to complications and the majority have not undergone repair.

  5. Suture versus tack fixation of mesh in laparoscopic umbilical hernia repair.

    PubMed

    Kitamura, Riley K; Choi, Jacqueline; Lynn, Elizabeth; Divino, Celia M

    2013-01-01

    Mesh fixation in laparoscopic umbilical hernia repair is poorly studied. We compared postoperative outcomes of laparoscopic umbilical hernia repair in suture versus tack mesh fixation. Patients who underwent laparoscopic umbilical hernia repair were separated by method of mesh fixation: sutures versus primarily tacks. Medical history and follow-up data were collected through medical records. The primary outcome of this study was the recurrence rates of hernias. Postoperative major and minor complications, such as surgical site infection, small-bowel obstruction, and seroma formation, were regarded as secondary outcomes. Additionally, a telephone interview was conducted to assess postoperative pain, recovery time, and overall patient satisfaction. Eighty-six patients were identified: 33 in the suture group and 53 in the tacks group. The number of emergent cases was increased in the tacks group (6 vs 0; P = .022). Mean follow-up time was 2.7 years for both groups. Documented postoperative follow-up was obtained in 29 (90%) suture group and 31 (58%) tacks group patients. Hernia recurrence occurred in 3 and 2 patients in the sutures and tacks groups, respectively (P was not significant). No differences were found in secondary outcomes, including subjective outcomes from telephone interviews, between groups. There are no differences in postoperative complication rates in suture versus tack mesh fixation in laparoscopic umbilical hernia repair.

  6. Fetal demise by umbilical cord around abdomen and stricture.

    PubMed

    Tan, Shun-Jen; Chen, Chi-Huang; Wu, Gwo-Jang; Chen, Wei-Hwa; Chang, Cheng-Chang

    2010-01-01

    Umbilical cord abnormalities are accepted as conditions associated with intrauterine fetal demise (IUFD), and umbilical cord stricture is most frequently encountered. In addition, although cord entanglement with multiple loops rarely increases the perinatal mortality, it is associated with a significant increase in variable kind of morbidity such as growth restriction. We describe a 27-year-old woman, with a missed abortion history at about 10 weeks' gestation in her first pregnancy, who presented to our outpatient department at 34 4/7 weeks of gestation due to decreased fetal activity during the preceding week. No fetal heart activity and blood flow had been detected by ultrasonography and pulsed-wave Doppler. A demised fetus with umbilical cord stricture and three loops around abdomen was delivered and was weighted 1,830 g that was below the tenth percentile for the gestational age. Either umbilical cord stricture or entanglement around the body can affect the development of the fetus and even be lethal. The former might play a more important role in this case. Their etiology and the sequence of the events are still undetermined, and additional evaluation such as autopsy and further research may be needed. In addition, counsel and frequent fetal surveillance should be done in patients with previous IUFD attributed to cord stricture during next pregnancy because of undetermined risk of recurrence.

  7. N-Acetylcysteine, a glutathione precursor, reverts vascular dysfunction and endothelial epigenetic programming in intrauterine growth restricted guinea pigs.

    PubMed

    Herrera, Emilio A; Cifuentes-Zúñiga, Francisca; Figueroa, Esteban; Villanueva, Cristian; Hernández, Cherie; Alegría, René; Arroyo-Jousse, Viviana; Peñaloza, Estefania; Farías, Marcelo; Uauy, Ricardo; Casanello, Paola; Krause, Bernardo J

    2017-02-15

    Intrauterine growth restriction (IUGR) is associated with vascular dysfunction, oxidative stress and signs of endothelial epigenetic programming of the umbilical vessels. There is no evidence that this epigenetic programming is occurring on systemic fetal arteries. In IUGR guinea pigs we studied the functional and epigenetic programming of endothelial nitric oxide synthase (eNOS) (Nos3 gene) in umbilical and systemic fetal arteries, addressing the role of oxidative stress in this process by maternal treatment with N-acetylcysteine (NAC) during the second half of gestation. The present study suggests that IUGR endothelial cells have common molecular markers of programming in umbilical and systemic arteries. Notably, maternal treatment with NAC restores fetal growth by increasing placental efficiency and reverting the functional and epigenetic programming of eNOS in arterial endothelium in IUGR guinea pigs. In humans, intrauterine growth restriction (IUGR) is associated with vascular dysfunction, oxidative stress and signs of endothelial programming in umbilical vessels. We aimed to determine the effects of maternal antioxidant treatment with N-acetylcysteine (NAC) on fetal endothelial function and endothelial nitric oxide synthase (eNOS) programming in IUGR guinea pigs. IUGR was induced by implanting ameroid constrictors on uterine arteries of pregnant guinea pigs at mid gestation, half of the sows receiving NAC in the drinking water (from day 34 until term). Fetal biometry and placental vascular resistance were followed by ultrasound throughout gestation. At term, umbilical arteries and fetal aortae were isolated to assess endothelial function by wire-myography. Primary cultures of endothelial cells (ECs) from fetal aorta, femoral and umbilical arteries were used to determine eNOS mRNA levels by quantitative PCR and analyse DNA methylation in the Nos3 promoter by pyrosequencing. Doppler ultrasound measurements showed that NAC reduced placental vascular resistance in IUGR (P < 0.05) and recovered fetal weight (P < 0.05), increasing fetal-to-placental ratio at term (∼40%) (P < 0.001). In IUGR, NAC treatment restored eNOS-dependent relaxation in aorta and umbilical arteries (P < 0.05), normalizing eNOS mRNA levels in EC fetal and umbilical arteries (P < 0.05). IUGR-derived ECs had a decreased DNA methylation (∼30%) at CpG -170 (from the transcription start site) and this epigenetic signature was absent in NAC-treated fetuses (P < 0.001). These data show that IUGR-ECs have common molecular markers of eNOS programming in umbilical and systemic arteries and this effect is prevented by maternal treatment with antioxidants. © 2016 The Authors. The Journal of Physiology © 2016 The Physiological Society.

  8. Evaluation of a New 1H/31P Dual-Tuned Birdcage Coil for 31P Spectroscopy

    PubMed Central

    Potter, WM; Wang, L; McCully, KK; Zhao, Q

    2013-01-01

    We introduce a new dual-tuned Hydrogen/Phosphorus (1H/31P) birdcage coil, referred to as split birdcage coil, and evaluate its performance using both simulations and magnetic resonance (MR) experiments on a 3 T MR scanner. The proposed coil simplifies the practical matters of tuning and matching, which makes the coil easily reproducible. Simulations were run with the Finite Difference in Time Domain (FDTD) method to evaluate the sensitivity and homogeneity of the magnetic field generated by the proposed 1H coils. Following simulations, MR experiments were conducted using both a phantom and human thigh to compare the proposed design with a currently available commercial dual-tuned flexible surface coil, referred to as flex surface coil, for signal to noise ratio (SNR) as well as homogeneity for the 31P coil. At regions deep within the human thigh, the split birdcage coil was able to acquire spectroscopic signal with a higher average SNR than the flex surface coil. For all regions except those close to the flex surface coil, the split birdcage coil matched or exceeded the performance of the flex surface coil. PMID:24039555

  9. Computational study for the effects of coil configuration on blood flow characteristics in coil-embolized cerebral aneurysm.

    PubMed

    Otani, Tomohiro; Ii, Satoshi; Shigematsu, Tomoyoshi; Fujinaka, Toshiyuki; Hirata, Masayuki; Ozaki, Tomohiko; Wada, Shigeo

    2017-05-01

    Coil embolization of cerebral aneurysms with inhomogeneous coil distribution leads to an incomplete occlusion of the aneurysm. However, the effects of this factor on the blood flow characteristics are still not fully understood. This study investigates the effects of coil configuration on the blood flow characteristics in a coil-embolized aneurysm using computational fluid dynamics (CFD) simulation. The blood flow analysis in the aneurysm with coil embolization was performed using a coil deployment (CD) model, in which the coil configuration was constructed using a physics-based simulation of the CD. In the CFD results, total flow momentum and kinetic energy in the aneurysm gradually decayed with increasing coil packing density (PD), regardless of the coil configuration attributed to deployment conditions. However, the total shear rate in the aneurysm was relatively high and the strength of the local shear flow varied based on the differences in coil configuration, even at adequate PDs used in clinical practice (20-25 %). Because the sufficient shear rate reduction is a well-known factor in the blood clot formation occluding the aneurysm inside, the present study gives useful insight into the effects of coil configuration on the treatment efficiency of coil embolization.

  10. Method and apparatus for magnetic resonance imaging and spectroscopy using microstrip transmission line coils

    DOEpatents

    Zhang, Xiaoliang; Ugurbil, Kamil; Chen, Wei

    2006-04-04

    Apparatus and method for MRI imaging using a coil constructed of microstrip transmission line (MTL coil) are disclosed. In one method, a target is positioned to be imaged within the field of a main magnetic field of a magnet resonance imaging (MRI) system, a MTL coil is positioned proximate the target, and a MRI image is obtained using the main magnet and the MTL coil. In another embodiment, the MRI coil is used for spectroscopy. MRI imaging and spectroscopy coils are formed using microstrip transmission line. These MTL coils have the advantageous property of good performance while occupying a relatively small space, thus allowing MTL coils to be used inside restricted areas more easily than some other prior art coils. In addition, the MTL coils are relatively simple to construct of inexpensive components and thus relatively inexpensive compared to other designs. Further, the MTL coils of the present invention can be readily formed in a wide variety of coil configurations, and used in a wide variety of ways. Further, while the MTL coils of the present invention work well at high field strengths and frequencies, they also work at low frequencies and in low field strengths as well.

  11. Apparatus and method for reducing inductive coupling between levitation and drive coils within a magnetic propulsion system

    DOEpatents

    Post, Richard F.

    2001-01-01

    An apparatus and method is disclosed for reducing inductive coupling between levitation and drive coils within a magnetic levitation system. A pole array has a magnetic field. A levitation coil is positioned so that in response to motion of the magnetic field of the pole array a current is induced in the levitation coil. A first drive coil having a magnetic field coupled to drive the pole array also has a magnetic flux which induces a parasitic current in the levitation coil. A second drive coil having a magnetic field is positioned to attenuate the parasitic current in the levitation coil by canceling the magnetic flux of the first drive coil which induces the parasitic current. Steps in the method include generating a magnetic field with a pole array for levitating an object; inducing current in a levitation coil in response to motion of the magnetic field of the pole array; generating a magnetic field with a first drive coil for propelling the object; and generating a magnetic field with a second drive coil for attenuating effects of the magnetic field of the first drive coil on the current in the levitation coil.

  12. Characteristics of bowl-shaped coils for transcranial magnetic stimulation

    NASA Astrophysics Data System (ADS)

    Yamamoto, Keita; Suyama, Momoko; Takiyama, Yoshihiro; Kim, Dongmin; Saitoh, Youichi; Sekino, Masaki

    2015-05-01

    Transcranial magnetic stimulation (TMS) has recently been used as a method for the treatment of neurological and psychiatric diseases. Daily TMS sessions can provide continuous therapeutic effectiveness, and the installation of TMS systems at patients' homes has been proposed. A figure-eight coil, which is normally used for TMS therapy, induces a highly localized electric field; however, it is challenging to achieve accurate coil positioning above the targeted brain area using this coil. In this paper, a bowl-shaped coil for stimulating a localized but wider area of the brain is proposed. The coil's electromagnetic characteristics were analyzed using finite element methods, and the analysis showed that the bowl-shaped coil induced electric fields in a wider area of the brain model than a figure-eight coil. The expanded distribution of the electric field led to greater robustness of the coil to the coil-positioning error. To improve the efficiency of the coil, the relationship between individual coil design parameters and the resulting coil characteristics was numerically analyzed. It was concluded that lengthening the outer spherical radius and narrowing the width of the coil were effective methods for obtaining a more effective and more uniform distribution of the electric field.

  13. Kinetic studies on strand displacement in de novo designed parallel heterodimeric coiled coils.

    PubMed

    Groth, Mike C; Rink, W Mathis; Meyer, Nils F; Thomas, Franziska

    2018-05-14

    Among the protein folding motifs, which are accessible by de novo design, the parallel heterodimeric coiled coil is most frequently used in bioinspired applications and chemical biology in general. This is due to the straightforward sequence-to-structure relationships, which it has in common with all coiled-coil motifs, and the heterospecificity, which allows control of association. Whereas much focus was laid on designing orthogonal coiled coils, systematic studies on controlling association, for instance by strand displacement, are rare. As a contribution to the design of dynamic coiled-coil-based systems, we studied the strand-displacement mechanism in obligate heterodimeric coiled coils to investigate the suitability of the dissociation constants ( K D ) as parameters for the prediction of the outcome of strand-displacement reactions. We use two sets of heterodimeric coiled coils, the previously reported N-A x B y and the newly characterized C-A x B y . Both comprise K D values in the μM to sub-nM regime. Strand displacement is explored by CD titration and a FRET-based kinetic assay and is proved to be an equilibrium reaction with half-lifes from a few seconds up to minutes. We could fit the displacement data by a competitive binding model, giving rate constants and overall affinities of the underlying association and dissociation reactions. The overall affinities correlate well with the ratios of K D values determined by CD-thermal denaturation experiments and, hence, support the dissociative mechanism of strand displacement in heterodimeric coiled coils. From the results of more than 100 different displacement reactions we are able to classify three categories of overall affinities, which allow for easy prediction of the equilibrium of strand displacement in two competing heterodimeric coiled coils.

  14. Structural mapping of the coiled-coil domain of a bacterial condensin and comparative analyses across all domains of life suggest conserved features of SMC proteins.

    PubMed

    Waldman, Vincent M; Stanage, Tyler H; Mims, Alexandra; Norden, Ian S; Oakley, Martha G

    2015-06-01

    The structural maintenance of chromosomes (SMC) proteins form the cores of multisubunit complexes that are required for the segregation and global organization of chromosomes in all domains of life. These proteins share a common domain structure in which N- and C- terminal regions pack against one another to form a globular ATPase domain. This "head" domain is connected to a central, globular, "hinge" or dimerization domain by a long, antiparallel coiled coil. To date, most efforts for structural characterization of SMC proteins have focused on the globular domains. Recently, however, we developed a method to map interstrand interactions in the 50-nm coiled-coil domain of MukB, the divergent SMC protein found in γ-proteobacteria. Here, we apply that technique to map the structure of the Bacillus subtilis SMC (BsSMC) coiled-coil domain. We find that, in contrast to the relatively complicated coiled-coil domain of MukB, the BsSMC domain is nearly continuous, with only two detectable coiled-coil interruptions. Near the middle of the domain is a break in coiled-coil structure in which there are three more residues on the C-terminal strand than on the N-terminal strand. Close to the head domain, there is a second break with a significantly longer insertion on the same strand. These results provide an experience base that allows an informed interpretation of the output of coiled-coil prediction algorithms for this family of proteins. A comparison of such predictions suggests that these coiled-coil deviations are highly conserved across SMC types in a wide variety of organisms, including humans. © 2015 Wiley Periodicals, Inc.

  15. Design of catheter radio frequency coils using coaxial transmission line resonators for interventional neurovascular MR imaging.

    PubMed

    Zhang, Xiaoliang; Martin, Alastair; Jordan, Caroline; Lillaney, Prasheel; Losey, Aaron; Pang, Yong; Hu, Jeffrey; Wilson, Mark; Cooke, Daniel; Hetts, Steven W

    2017-04-01

    It is technically challenging to design compact yet sensitive miniature catheter radio frequency (RF) coils for endovascular interventional MR imaging. In this work, a new design method for catheter RF coils is proposed based on the coaxial transmission line resonator (TLR) technique. Due to its distributed circuit, the TLR catheter coil does not need any lumped capacitors to support its resonance, which simplifies the practical design and construction and provides a straightforward technique for designing miniature catheter-mounted imaging coils that are appropriate for interventional neurovascular procedures. The outer conductor of the TLR serves as an RF shield, which prevents electromagnetic energy loss, and improves coil Q factors. It also minimizes interaction with surrounding tissues and signal losses along the catheter coil. To investigate the technique, a prototype catheter coil was built using the proposed coaxial TLR technique and evaluated with standard RF testing and measurement methods and MR imaging experiments. Numerical simulation was carried out to assess the RF electromagnetic field behavior of the proposed TLR catheter coil and the conventional lumped-element catheter coil. The proposed TLR catheter coil was successfully tuned to 64 MHz for proton imaging at 1.5 T. B 1 fields were numerically calculated, showing improved magnetic field intensity of the TLR catheter coil over the conventional lumped-element catheter coil. MR images were acquired from a dedicated vascular phantom using the TLR catheter coil and also the system body coil. The TLR catheter coil is able to provide a significant signal-to-noise ratio (SNR) increase (a factor of 200 to 300) over its imaging volume relative to the body coil. Catheter imaging RF coil design using the proposed coaxial TLR technique is feasible and advantageous in endovascular interventional MR imaging applications.

  16. Measurement of heating coil temperature for e-cigarettes with a "top-coil" clearomizer.

    PubMed

    Chen, Wenhao; Wang, Ping; Ito, Kazuhide; Fowles, Jeff; Shusterman, Dennis; Jaques, Peter A; Kumagai, Kazukiyo

    2018-01-01

    To determine the effect of applied power settings, coil wetness conditions, and e-liquid compositions on the coil heating temperature for e-cigarettes with a "top-coil" clearomizer, and to make associations of coil conditions with emission of toxic carbonyl compounds by combining results herein with the literature. The coil temperature of a second generation e-cigarette was measured at various applied power levels, coil conditions, and e-liquid compositions, including (1) measurements by thermocouple at three e-liquid fill levels (dry, wet-through-wick, and full-wet), three coil resistances (low, standard, and high), and four voltage settings (3-6 V) for multiple coils using propylene glycol (PG) as a test liquid; (2) measurements by thermocouple at additional degrees of coil wetness for a high resistance coil using PG; and (3) measurements by both thermocouple and infrared (IR) camera for high resistance coils using PG alone and a 1:1 (wt/wt) mixture of PG and glycerol (PG/GL). For single point thermocouple measurements with PG, coil temperatures ranged from 322 ‒ 1008°C, 145 ‒ 334°C, and 110 ‒ 185°C under dry, wet-through-wick, and full-wet conditions, respectively, for the total of 13 replaceable coil heads. For conditions measured with both a thermocouple and an IR camera, all thermocouple measurements were between the minimum and maximum across-coil IR camera measurements and equal to 74% ‒ 115% of the across-coil mean, depending on test conditions. The IR camera showed details of the non-uniform temperature distribution across heating coils. The large temperature variations under wet-through-wick conditions may explain the large variations in formaldehyde formation rate reported in the literature for such "top-coil" clearomizers. This study established a simple and straight-forward protocol to systematically measure e-cigarette coil heating temperature under dry, wet-through-wick, and full-wet conditions. In addition to applied power, the composition of e-liquid, and the devices' ability to efficiently deliver e-liquid to the heating coil are important product design factors effecting coil operating temperature. Precautionary temperature checks on e-cigarettes under manufacturer-recommended normal use conditions may help to reduce the health risks from exposure to toxic carbonyl emissions associated with coil overheating.

  17. Comparison of endorectal coil and nonendorectal coil T2W and diffusion-weighted MRI at 3 Tesla for localizing prostate cancer: correlation with whole-mount histopathology.

    PubMed

    Turkbey, Baris; Merino, Maria J; Gallardo, Elma Carvajal; Shah, Vijay; Aras, Omer; Bernardo, Marcelino; Mena, Esther; Daar, Dagane; Rastinehad, Ardeshir R; Linehan, W Marston; Wood, Bradford J; Pinto, Peter A; Choyke, Peter L

    2014-06-01

    To compare utility of T2-weighted (T2W) MRI and diffusion-weighted MRI (DWI-MRI) obtained with and without an endorectal coil at 3 Tesla (T) for localizing prostate cancer. This Institutional Review Board-approved study included 20 patients (median prostate-specific antigen, 8.4 ng/mL). Patients underwent consecutive prostate MRIs at 3T, first with a surface coil alone, then with combination of surface, endorectal coils (dual coil) followed by robotic assisted radical prostatectomy. Lesions were mapped at time of acquisition on dual-coil T2W, DWI-MRI. To avoid bias, 6 months later nonendorectal coil T2W, DWI-MRI were mapped. Both MRI evaluations were performed by two readers blinded to pathology with differences resolved by consensus. A lesion-based correlation with whole-mount histopathology was performed. At histopathology 51 cancer foci were present ranging in size from 2 to 60 mm. The sensitivity of the endorectal dual-coil, nonendorectal coil MRIs were 0.76, 0.45, respectively. PPVs for endorectal dual-coil, nonendorectal coil MRI were 0.80, 0.64, respectively. Mean size of detected lesions with nonendorectal coil MRI were larger than those detected by dual-coil MRI (22 mm versus 17.4 mm). Dual-coil prostate MRI detected more cancer foci than nonendorectal coil MRI. While nonendorectal coil MRI is an attractive alternative, physicians performing prostate MRI should be aware of its limitations. Copyright © 2013 Wiley Periodicals, Inc.

  18. Sensitivity of an eight-element phased array coil in 3 Tesla MR imaging: a basic analysis.

    PubMed

    Hiratsuka, Yoshiyasu; Miki, Hitoshi; Kikuchi, Keiichi; Kiriyama, Ikuko; Mochizuki, Teruhito; Takahashi, Shizue; Sadamoto, Kazuhiko

    2007-01-01

    To evaluate the performance advantages of an 8-element phased array head coil (8 ch coil) over a conventional quadrature-type birdcage head coil (QD coil) with regard to the signal-to-noise ratio (SNR) and image uniformity in 3 Tesla magnetic resonance (MR) imaging. We scanned a phantom filled with silicon oil using an 8 ch coil and a QD coil in a 3T MR imaging system and compared the SNR and image uniformity obtained from T(1)-weighted spin echo (SE) images and T(2)-weighted fast SE images between the 2 coils. We also visually evaluated images from 4 healthy volunteers. The SNR with the 8 ch coil was approximately twice that with the QD coil in the region of interest (ROI), which was set as 75% of the area in the center of the phantom images. With regard to the spatial variation of sensitivity, the SNR with the 8 ch coil was lower at the center of the images than at the periphery, whereas the SNR with the QD coil exhibited an inverse pattern. At the center of the images with the 8 ch coil, the SNR was somewhat lower, and that distribution was relatively flat compared to that in the periphery. Image uniformity varied less with the 8 ch coil than with the QD coil on both imaging sequences. The 8 ch phased array coil was useful for obtaining high quality 3T images because of its higher SNR and improved image uniformity than those obtained with conventional quadrature-type birdcage head coil.

  19. Crystal Structure of a Coiled-Coil Domain from Human ROCK I

    PubMed Central

    Tu, Daqi; Li, Yiqun; Song, Hyun Kyu; Toms, Angela V.; Gould, Christopher J.; Ficarro, Scott B.; Marto, Jarrod A.; Goode, Bruce L.; Eck, Michael J.

    2011-01-01

    The small GTPase Rho and one of its targets, Rho-associated kinase (ROCK), participate in a variety of actin-based cellular processes including smooth muscle contraction, cell migration, and stress fiber formation. The ROCK protein consists of an N-terminal kinase domain, a central coiled-coil domain containing a Rho binding site, and a C-terminal pleckstrin homology domain. Here we present the crystal structure of a large section of the central coiled-coil domain of human ROCK I (amino acids 535–700). The structure forms a parallel α-helical coiled-coil dimer that is structurally similar to tropomyosin, an actin filament binding protein. There is an unusual discontinuity in the coiled-coil; three charged residues (E613, R617 and D620) are positioned at what is normally the hydrophobic core of coiled-coil packing. We speculate that this conserved irregularity could function as a hinge that allows ROCK to adopt its autoinhibited conformation. PMID:21445309

  20. Performance evaluation of matrix gradient coils.

    PubMed

    Jia, Feng; Schultz, Gerrit; Testud, Frederik; Welz, Anna Masako; Weber, Hans; Littin, Sebastian; Yu, Huijun; Hennig, Jürgen; Zaitsev, Maxim

    2016-02-01

    In this paper, we present a new performance measure of a matrix coil (also known as multi-coil) from the perspective of efficient, local, non-linear encoding without explicitly considering target encoding fields. An optimization problem based on a joint optimization for the non-linear encoding fields is formulated. Based on the derived objective function, a figure of merit of a matrix coil is defined, which is a generalization of a previously known resistive figure of merit for traditional gradient coils. A cylindrical matrix coil design with a high number of elements is used to illustrate the proposed performance measure. The results are analyzed to reveal novel features of matrix coil designs, which allowed us to optimize coil parameters, such as number of coil elements. A comparison to a scaled, existing multi-coil is also provided to demonstrate the use of the proposed performance parameter. The assessment of a matrix gradient coil profits from using a single performance parameter that takes the local encoding performance of the coil into account in relation to the dissipated power.

  1. Cool-Down and Current Test Results of the KSTAR Prototype TF Coil

    NASA Astrophysics Data System (ADS)

    Oh, Y. K.; Lee, S.; Chu, Y.; Park, K. R.; Yonekawa, H.; Baek, S. H.; Cho, K. W.; Park, Y. M.; Kim, M. K.; Chang, H. S.; Kim, Y. S.; Chang, Y. B.; Lee, Y. J.; Kim, W. C.; Kim, K.; Kwag, S. W.; Lee, S. H.; Yang, S. H.; Lee, S. J.; Bak, J. S.; Lee, G. S.

    2004-06-01

    A prototype toroidal field (TF) coil, TF00 coil, of the Korea Superconducting Tokamak Advanced Research (KSTAR) project has been assembled and tested at the coil test facility in Korea Basic Science Institute (KBSI). The TF00 coil is a real-sized TF coil made of Nb3Sn superconducting cable-in-conduit conductor (CICC). The coil test was conducted by several campaigns according to the objectives. The first campaign, which was carried out by Jan. 2003, has objectives of cooling the coil into operating temperature and finding any defect in the coil such as cold leaks. From the results of the first campaign experiment, any defect in the coil was not found. The second campaign, which was carried out by Aug. 2003, has objectives to get the operating characteristics according to the current ramp up and discharge operations. In this paper, the coil test results are introduced as well as the details of the coil test system setup.

  2. Crystal Structure of the Central Coiled-Coil Domain from Human Liprin-[beta]2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stafford, Ryan L.; Tang, Ming-Yun; Sawaya, Michael R.

    2012-02-07

    Liprins are a conserved family of scaffolding proteins important for the proper regulation and development of neuronal synapses. Humans have four liprin-{alpha}s and two liprin-{beta}s which all contain long coiled-coil domains followed by three tandem SAM domains. Complex interactions between the coiled-coil and SAM domains are thought to create liprin scaffolds, but the structural and biochemical properties of these domains remain largely uncharacterized. In this study we find that the human liprin-{beta}2 coiled-coil forms an extended dimer. Several protease-resistant subdomains within the liprin-{beta}1 and liprin-{beta}2 coiled-coils were also identified. A 2.0 {angstrom} crystal structure of the central, protease-resistant core ofmore » the liprin-{beta}2 coiled-coil reveals a parallel helix orientation. These studies represent an initial step toward determining the overall architecture of liprin scaffolds and understanding the molecular basis for their synaptic functions.« less

  3. Dynamic allostery of protein alpha helical coiled-coils

    PubMed Central

    Hawkins, Rhoda J; McLeish, Tom C.B

    2005-01-01

    Alpha helical coiled-coils appear in many important allosteric proteins such as the dynein molecular motor and bacteria chemotaxis transmembrane receptors. As a mechanism for transmitting the information of ligand binding to a distant site across an allosteric protein, an alternative to conformational change in the mean static structure is an induced change in the pattern of the internal dynamics of the protein. We explore how ligand binding may change the intramolecular vibrational free energy of a coiled-coil, using parameterized coarse-grained models, treating the case of dynein in detail. The models predict that coupling of slide, bend and twist modes of the coiled-coil transmits an allosteric free energy of ∼2kBT, consistent with experimental results. A further prediction is a quantitative increase in the effective stiffness of the coiled-coil without any change in inherent flexibility of the individual helices. The model provides a possible and experimentally testable mechanism for transmission of information through the alpha helical coiled-coil of dynein. PMID:16849225

  4. [Development of RF coil of permanent magnet mini-magnetic resonance imager and mouse imaging experiments].

    PubMed

    Hou, Shulian; Xie, Huantong; Chen, Wei; Wang, Guangxin; Zhao, Qiang; Li, Shiyu

    2014-10-01

    In the development of radio frequency (RF) coils for better quality of the mini-type permanent magnetic resonance imager for using in the small animal imaging, the solenoid RF coil has a special advantage for permanent magnetic system based on analyses of various types.of RF coils. However, it is not satisfied for imaging if the RF coils are directly used. By theoretical analyses of the magnetic field properties produced from the solenoid coil, the research direction was determined by careful studies to raise further the uniformity of the magnetic field coil, receiving coil sensitivity for signals and signal-to-noise ratio (SNR). The method had certain advantages and avoided some shortcomings of the other different coil types, such as, birdcage coil, saddle shaped coil and phased array coil by using the alloy materials (from our own patent). The RF coils were designed, developed and made for keeled applicable to permanent magnet-type magnetic resonance imager, multi-coil combination-type, single-channel overall RF receiving coil, and applied for a patent. Mounted on three instruments (25 mm aperture, with main magnetic field strength of 0.5 T or 1.5 T, and 50 mm aperture, with main magnetic field strength of 0.48 T), we performed experiments with mice, rats, and nude mice bearing tumors. The experimental results indicated that the RF receiving coil was fully applicable to the permanent magnet-type imaging system.

  5. A Mechanical Coil Insertion System for Endovascular Coil Embolization of Intracranial Aneurysms

    PubMed Central

    Haraguchi, K.; Miyachi, S.; Matsubara, N.; Nagano, Y.; Yamada, H.; Marui, N.; Sano, A.; Fujimoto, H.; Izumi, T.; Yamanouchi, T.; Asai, T.; Wakabayashi, T.

    2013-01-01

    Summary Like other fields of medicine, robotics and mechanization might be introduced into endovascular coil embolization of intracranial aneurysms for effective treatment. We have already reported that coil insertion force could be smaller and more stable when the coil delivery wire is driven mechanically at a constant speed. Another background is the difficulty in synchronizing operators' minds and hands when two operators control the microcatheter and the coil respectively. We have therefore developed a mechanical coil insertion system enabling a single operator to insert coils at a fixed speed while controlling the microcatheter. Using our new system, the operator manipulated the microcatheter with both hands and drove the coil using foot switches simultaneously. A delivery wire force sensor previously reported was used concurrently, allowing the operator to detect excessive stress on the wire. In vitro coil embolization was performed using three methods: simple mechanical advance of the coil; simple mechanical advance of the coil with microcatheter control; and driving (forward and backward) of the coil using foot switches in addition to microcatheter control. The system worked without any problems, and did not interfere with any procedures. In experimental coil embolization, delivery wire control using the foot switches as well as microcatheter manipulation helped to achieve successful insertion of coils. This system could offer the possibility of developing safer and more efficient coil embolization. Although we aim at total mechanization and automation of procedures in the future, microcatheter manipulation and synchronized delivery wire control are still indispensable using this system. PMID:23693038

  6. Flux pumping for non-insulated and metal-insulated HTS coils

    NASA Astrophysics Data System (ADS)

    Ma, Jun; Geng, Jianzhao; Coombs, T. A.

    2018-01-01

    High-temperature superconducting (HTS) coils wound from coated conductors without turn-to-turn insulation (non-insulated (NI) coils) have been proven with excellent electrical and thermal performances. However, the slow charging of NI coils has been a long-lasting problem. In this work, we explore using a transformer-rectifier HTS flux pump to charge an NI coil and a metal-insulated coil. The charging performance comparison is made between different coils. Comprehensive study is done to thoroughly understand the electrical-magnetic transience in charging these coils. We will show that the low-voltage high-current flux pump is especially suitable for charging NI coils with very low characteristic resistance.

  7. Endovascular rescue method for undesirably stretched coil.

    PubMed

    Cho, Jae Hoon

    2014-10-01

    Undesirable detachment or stretching of coils within the parent artery during aneurysm embolization can be related with thrombus formation, which can be caused occlusion of parent artery or embolic event(s). To escape from this situation, several rescue methods have been reported. A case with undesirably stretched coil in which another rescue method was used, is presented. When the stretched coil is still located in the coil delivery microcatheter, the stretched coil can be removed safely using a snare and a handmade monorail microcatheter. After a snare is lodged in the handmade monorail microcatheter, the snare is introduced over the coil delivery micorcatheter and located in the distal part of the stretched coil. After then, the handmade monorail microcatheter captures the stretched coil and the snare as one unit. This technique using a handmade monorail microcatheter and a snare can be a good rescue modality for the undesirably stretched coil, still remained within the coil delivery microcatheter.

  8. Endovascular Rescue Method for Undesirably Stretched Coil

    PubMed Central

    2014-01-01

    Undesirable detachment or stretching of coils within the parent artery during aneurysm embolization can be related with thrombus formation, which can be caused occlusion of parent artery or embolic event(s). To escape from this situation, several rescue methods have been reported. A case with undesirably stretched coil in which another rescue method was used, is presented. When the stretched coil is still located in the coil delivery microcatheter, the stretched coil can be removed safely using a snare and a handmade monorail microcatheter. After a snare is lodged in the handmade monorail microcatheter, the snare is introduced over the coil delivery micorcatheter and located in the distal part of the stretched coil. After then, the handmade monorail microcatheter captures the stretched coil and the snare as one unit. This technique using a handmade monorail microcatheter and a snare can be a good rescue modality for the undesirably stretched coil, still remained within the coil delivery microcatheter. PMID:25371791

  9. Radiation-hard electrical coil and method for its fabrication

    DOEpatents

    Grieggs, R.J.; Blake, R.D.; Gac, F.D.

    1982-06-29

    A radiation-hard insulated electrical coil and method for making the same are disclosed. In accordance with the method, a conductor, preferably copper, is wrapped with an aluminum strip and then tightly wound into a coil. The aluminum-wrapped coil is then annealed to relax the conductor in the coiled configuration. The annealed coil is then immersed in an alkaline solution to dissolve the aluminum strip, leaving the bare conductor in a coiled configuration with all of the windings closely packed yet uniformly spaced from one another. The coil is then insulated with a refractory insulating material. In the preferred embodiment, the coil is insulated by coating it with a vitreous enamel and subsequently potting the enamelled coil in a castable ceramic concrete. The resulting coil is substantially insensitive to radiation and may be operated continuously in high radiation environments for long periods of time.

  10. Development and positioning reliability of a TMS coil holder for headache research.

    PubMed

    Chronicle, Edward P; Pearson, A Jane; Matthews, Cheryl

    2005-01-01

    Accurate and reproducible coil positioning is important for headache research using transcranial magnetic stimulation protocols. We aimed to design a transcranial magnetic stimulation coil holder and demonstrate reliability of test-retest coil positioning. A coil holder was developed and manufactured according to three principles of stability, durability, and three-dimensional positional accuracy. Reliability of coil positioning was assessed by stimulating over the motor cortex of four neurologically normal subjects and recording finger muscle responses, both at a test phase and a retest phase several hours later. In all four subjects, repositioning of the transcranial magnetic stimulation coil solely on the basis of coil holder coordinates was accurate to within 2 mm. The coil holder demonstrated good test-retest reliability of coil positioning, and is thus a promising tool for transcranial magnetic stimulation-based headache research, particularly studies of prophylactic drug effect where several laboratory visits with identical coil positioning are necessary.

  11. Inductance and resistance measurement method for vessel detection and coil powering in all-surface inductive heating systems composed of outer squircle coils

    NASA Astrophysics Data System (ADS)

    Kilic, Veli Tayfun; Unal, Emre; Demir, Hilmi Volkan

    2017-05-01

    In this work, we investigate a method proposed for vessel detection and coil powering in an all-surface inductive heating system composed of outer squircle coils. Besides conventional circular coils, coils with different shapes such as outer squircle coils are used for and enable efficient all-surface inductive heating. Validity of the method, which relies on measuring inductance and resistance values of a loaded coil at different frequencies, is experimentally demonstrated for a coil with shape different from conventional circular coil. Simple setup was constructed with a small coil to model an all-surface inductive heating system. Inductance and resistance maps were generated by measuring coil's inductance and resistance values at different frequencies loaded by a plate made of different materials and located at various positions. Results show that in an induction hob for various coil geometries it is possible to detect a vessel's presence, to identify its material type and to specify its position on the hob surface by considering inductance and resistance of the coil measured on at least two different frequencies. The studied method is important in terms of enabling safe, efficient and user flexible heating in an all-surface inductive heating system by automatically detecting the vessel's presence and powering on only the coils that are loaded by the vessel with predetermined current levels.

  12. Insulin restores gestational diabetes mellitus-reduced adenosine transport involving differential expression of insulin receptor isoforms in human umbilical vein endothelium.

    PubMed

    Westermeier, Francisco; Salomón, Carlos; González, Marcelo; Puebla, Carlos; Guzmán-Gutiérrez, Enrique; Cifuentes, Fredi; Leiva, Andrea; Casanello, Paola; Sobrevia, Luis

    2011-06-01

    To determine whether insulin reverses gestational diabetes mellitus (GDM)-reduced expression and activity of human equilibrative nucleoside transporters 1 (hENT1) in human umbilical vein endothelium cells (HUVECs). Primary cultured HUVECs from full-term normal (n = 44) and diet-treated GDM (n = 44) pregnancies were used. Insulin effect was assayed on hENT1 expression (protein, mRNA, SLC29A1 promoter activity) and activity (initial rates of adenosine transport) as well as endothelial nitric oxide (NO) synthase activity (serine(1177) phosphorylation, l-citrulline formation). Adenosine concentration in culture medium and umbilical vein blood (high-performance liquid chromatography) as well as insulin receptor A and B expression (quantitative PCR) were determined. Reactivity of umbilical vein rings to adenosine and insulin was assayed by wire myography. Experiments were in the absence or presence of l-N(G)-nitro-l-arginine methyl ester (l-NAME; NO synthase inhibitor) or ZM-241385 (an A(2A)-adenosine receptor antagonist). Umbilical vein blood adenosine concentration was higher, and the adenosine- and insulin-induced NO/endothelium-dependent umbilical vein relaxation was lower in GDM. Cells from GDM exhibited increased insulin receptor A isoform expression in addition to the reported NO-dependent inhibition of hENT1-adenosine transport and SLC29A1 reporter repression, and increased extracellular concentration of adenosine and NO synthase activity. Insulin reversed all these parameters to values in normal pregnancies, an effect blocked by ZM-241385 and l-NAME. GDM and normal pregnancy HUVEC phenotypes are differentially responsive to insulin, a phenomenon where insulin acts as protecting factor for endothelial dysfunction characteristic of this syndrome. Abnormal adenosine plasma levels, and potentially A(2A)-adenosine receptors and insulin receptor A, will play crucial roles in this phenomenon in GDM.

  13. A risk factor analysis of outcomes after unrelated cord blood transplantation for children with Wiskott-Aldrich syndrome

    PubMed Central

    Shekhovtsova, Zhanna; Bonfim, Carmem; Ruggeri, Annalisa; Nichele, Samantha; Page, Kristin; AlSeraihy, Amal; Barriga, Francisco; de Toledo Codina, José Sánchez; Veys, Paul; Boelens, Jaap Jan; Mellgren, Karin; Bittencourt, Henrique; O’Brien, Tracey; Shaw, Peter J.; Chybicka, Alicja; Volt, Fernanda; Giannotti, Federica; Gluckman, Eliane; Kurtzberg, Joanne; Gennery, Andrew R.; Rocha, Vanderson

    2017-01-01

    Wiskott-Aldrich syndrome is a severe X-linked recessive immune deficiency disorder. A scoring system of Wiskott-Aldrich syndrome severity (0.5–5) distinguishes two phenotypes: X-linked thrombocytopenia and classic Wiskott-Aldrich syndrome. Hematopoietic cell transplantation is curative for Wiskott-Aldrich syndrome; however, the use of unrelated umbilical cord blood transplantation has seldom been described. We analyzed umbilical cord blood transplantation outcomes for 90 patients. The median age at umbilical cord blood transplantation was 1.5 years. Patients were classified according to clinical scores [2 (23%), 3 (30%), 4 (23%) and 5 (19%)]. Most patients underwent HLA-mismatched umbilical cord blood transplantation and myeloablative conditioning with anti-thymocyte globulin. The cumulative incidence of neutrophil recovery at day 60 was 89% and that of grade II–IV acute graft-versus-host disease at day 100 was 38%. The use of methotrexate for graft-versus-host disease prophylaxis delayed engraftment (P=0.02), but decreased acute graft-versus-host disease (P=0.03). At 5 years, overall survival and event-free survival rates were 75% and 70%, respectively. The estimated 5-year event-free survival rates were 83%, 73% and 55% for patients with a clinical score of 2, 4–5 and 3, respectively. In multivariate analysis, age <2 years at the time of the umbilical cord blood transplant and a clinical phenotype of X-linked thrombocytopenia were associated with improved event-free survival. Overall survival tended to be better in patients transplanted after 2007 (P=0.09). In conclusion, umbilical cord blood transplantation is a good alternative option for young children with Wiskott-Aldrich syndrome lacking an HLA identical stem cell donor. PMID:28255019

  14. Improvement of renal function after human umbilical cord mesenchymal stem cell treatment on chronic renal failure and thoracic spinal cord entrapment: a case report.

    PubMed

    Rahyussalim, Ahmad Jabir; Saleh, Ifran; Kurniawati, Tri; Lutfi, Andi Praja Wira Yudha

    2017-11-30

    Chronic renal failure is an important clinical problem with significant socioeconomic impact worldwide. Thoracic spinal cord entrapment induced by a metabolic yield deposit in patients with renal failure results in intrusion of nervous tissue and consequently loss of motor and sensory function. Human umbilical cord mesenchymal stem cells are immune naïve and they are able to differentiate into other phenotypes, including the neural lineage. Over the past decade, advances in the field of regenerative medicine allowed development of cell therapies suitable for kidney repair. Mesenchymal stem cell studies in animal models of chronic renal failure have uncovered a unique potential of these cells for improving function and regenerating the damaged kidney. We report a case of a 62-year-old ethnic Indonesian woman previously diagnosed as having thoracic spinal cord entrapment with paraplegic condition and chronic renal failure on hemodialysis. She had diabetes mellitus that affected her kidneys and had chronic renal failure for 2 years, with creatinine level of 11 mg/dl, and no urinating since then. She was treated with human umbilical cord mesenchymal stem cell implantation protocol. This protocol consists of implantation of 16 million human umbilical cord mesenchymal stem cells intrathecally and 16 million human umbilical cord mesenchymal stem cells intravenously. Three weeks after first intrathecal and intravenous implantation she could move her toes and her kidney improved. Her creatinine level decreased to 9 mg/dl. Now after 8 months she can raise her legs and her creatinine level is 2 mg/dl with normal urinating. Human umbilical cord mesenchymal stem cell implantations led to significant improvement for spinal cord entrapment and kidney failure. The major histocompatibility in allogeneic implantation is an important issue to be addressed in the future.

  15. A risk factor analysis of outcomes after unrelated cord blood transplantation for children with Wiskott-Aldrich syndrome.

    PubMed

    Shekhovtsova, Zhanna; Bonfim, Carmem; Ruggeri, Annalisa; Nichele, Samantha; Page, Kristin; AlSeraihy, Amal; Barriga, Francisco; de Toledo Codina, José Sánchez; Veys, Paul; Boelens, Jaap Jan; Mellgren, Karin; Bittencourt, Henrique; O'Brien, Tracey; Shaw, Peter J; Chybicka, Alicja; Volt, Fernanda; Giannotti, Federica; Gluckman, Eliane; Kurtzberg, Joanne; Gennery, Andrew R; Rocha, Vanderson

    2017-06-01

    Wiskott-Aldrich syndrome is a severe X-linked recessive immune deficiency disorder. A scoring system of Wiskott-Aldrich syndrome severity (0.5-5) distinguishes two phenotypes: X-linked thrombocytopenia and classic Wiskott-Aldrich syndrome. Hematopoietic cell transplantation is curative for Wiskott-Aldrich syndrome; however, the use of unrelated umbilical cord blood transplantation has seldom been described. We analyzed umbilical cord blood transplantation outcomes for 90 patients. The median age at umbilical cord blood transplantation was 1.5 years. Patients were classified according to clinical scores [2 (23%), 3 (30%), 4 (23%) and 5 (19%)]. Most patients underwent HLA-mismatched umbilical cord blood transplantation and myeloablative conditioning with anti-thymocyte globulin. The cumulative incidence of neutrophil recovery at day 60 was 89% and that of grade II-IV acute graft- versus -host disease at day 100 was 38%. The use of methotrexate for graft- versus -host disease prophylaxis delayed engraftment ( P =0.02), but decreased acute graft- versus -host disease ( P =0.03). At 5 years, overall survival and event-free survival rates were 75% and 70%, respectively. The estimated 5-year event-free survival rates were 83%, 73% and 55% for patients with a clinical score of 2, 4-5 and 3, respectively. In multivariate analysis, age <2 years at the time of the umbilical cord blood transplant and a clinical phenotype of X-linked thrombocytopenia were associated with improved event-free survival. Overall survival tended to be better in patients transplanted after 2007 ( P =0.09). In conclusion, umbilical cord blood transplantation is a good alternative option for young children with Wiskott-Aldrich syndrome lacking an HLA identical stem cell donor. Copyright© Ferrata Storti Foundation.

  16. The timing of umbilical cord clamping at birth: physiological considerations.

    PubMed

    Hooper, Stuart B; Binder-Heschl, Corinna; Polglase, Graeme R; Gill, Andrew W; Kluckow, Martin; Wallace, Euan M; Blank, Douglas; Te Pas, Arjan B

    2016-01-01

    While it is now recognized that umbilical cord clamping (UCC) at birth is not necessarily an innocuous act, there is still much confusion concerning the potential benefits and harms of this common procedure. It is most commonly assumed that delaying UCC will automatically result in a time-dependent net placental-to-infant blood transfusion, irrespective of the infant's physiological state. Whether or not this occurs, will likely depend on the infant's physiological state and not on the amount of time that has elapsed between birth and umbilical cord clamping (UCC). However, we believe that this is an overly simplistic view of what can occur during delayed UCC and ignores the benefits associated with maintaining the infant's venous return and cardiac output during transition. Recent experimental evidence and observations in humans have provided compelling evidence to demonstrate that time is not a major factor influencing placental-to-infant blood transfusion after birth. Indeed, there are many factors that influence blood flow in the umbilical vessels after birth, which depending on the dominating factors could potentially result in infant-to-placental blood transfusion. The most dominant factors that influence umbilical artery and venous blood flows after birth are lung aeration, spontaneous inspirations, crying and uterine contractions. It is still not entirely clear whether gravity differentially alters umbilical artery and venous flows, although the available data suggests that its influence, if present, is minimal. While there is much support for delaying UCC at birth, much of the debate has focused on a time-based approach, which we believe is misguided. While a time-based approach is much easier and convenient for the caregiver, ignoring the infant's physiology during delayed UCC can potentially be counter-productive for the infant.

  17. The umbilical and paraumbilical veins of man.

    PubMed

    Martin, B F; Tudor, R G

    1980-03-01

    During its transit through the umbilicus structural changes occur in the thick wall of the extra-abdominal segment of the umbilical vein whereby the components of the intra-abdominal segment acquire an essentially longitudinal direction and become arranged in fibro-elastic and fibro-muscular zones. The vein lumen becomes largely obliterated by asymmetrical proliferation of loose subendothelial conective tissue. The latter forms a new inner zone within which a small segment of the lumen persists in an eccentric position. This residual lumen transmits blood to the portal system from paraumbilical and systemic sources, and is retained in the upper part of the vein, even in old age. A similar process of lumen closure is observed in the ductus venosus. In early childhood the lower third of the vein undergoes breakdown, with fatty infiltration, resulting in its complete division into vascular fibro-elastic strands, and in old age some breakdown occurs in the outermost part of the wall of the upper two thirds. The paraumbilical veins are thick-walled and of similar structure to the umbilical vein. Together they constitute an accessory portal system which is confined between the layers of the falciform ligament and is in communication with the veins of the ventral abdominal wall. The constituents form an ascending series, namely, Burow's veins, the umbilical vein, and Sappey's inferior and superior veins. The main channel of Sappey's inferior veins may be the remnant of the right umbilical vein since it communicates with the right rectus sheath and often communicates directly with the portal system within the right lobe of the liver. The results are of significance in relation to clinical usage of the umbilical vein.

  18. Reappraisal of adhesive strapping as treatment for infantile umbilical hernia.

    PubMed

    Yanagisawa, Satohiko; Kato, Mototoshi; Oshio, Takehito; Morikawa, Yasuhide

    2016-05-01

    Most umbilical hernias spontaneously close by 3-5 years of age; therefore, surgical repair is considered only in children whose hernias have not closed by this point. At present, adhesive strapping is not the preferred treatment for umbilical hernias because of the lack of supporting evidence regarding its efficacy, and its association with skin complications. This aim of this study was to examine umbilical hernia closure on ultrasonography, and reassess the merits of adhesive strapping. Between January 2013 and December 2014, 89 infants underwent adhesive strapping for umbilical hernia. The strapping was changed once a week. The diameter of the hernia orifice was measured on ultrasonography every 2 weeks until closure. The closure speed (CS) of the hernia orifice was compared between the infants treated with adhesive strapping and those undergoing observation alone. The association between CS and birthweight, gestational age, diameter of the hernia orifice, and timing of treatment (before 12 weeks of age vs between 12 and 26 weeks of age) was also analyzed. Closure was achieved after 2-13 weeks of strapping in 81 infants (91%), and the likelihood of closure was not affected by the diameter of the hernia orifice, gestational age, or the timing of treatment. The mean CS of the infants treated with adhesive strapping was significantly faster than that of the infants undergoing observation alone (2.59 vs 0.37 mm/week, P < 0.05). Adhesive strapping was discontinued in five of the 89 infants (5.6%) due to severe skin complications. Adhesive strapping promoted early spontaneous umbilical hernia closure compared with observation alone, regardless of the diameter of the hernia orifice. Adhesive strapping is an effective alternative to surgery and observation. © 2015 Japan Pediatric Society.

  19. The Hernia-Neck-Ratio (HNR), a Novel Predictive Factor for Complications of Umbilical Hernia.

    PubMed

    Fueter, T; Schäfer, M; Fournier, P; Bize, P; Demartines, N; Allemann, P

    2016-09-01

    Umbilical hernia is a common pathology and surgical repair is advised to prevent complications in symptomatic patients. However, risk factors that predict such advert events are unknown. The aim of the study was to determine whether morphological characteristics are associated with the occurrence of complications. Retrospective review of adult patients with elective and emergent umbilical hernia repair operated from January 2004 to December 2013. The size of the hernia and the size of the neck were measured based on operative reports, ultrasound, CT or MRI images. The Hernia-Neck-Ratio (HNR) was then calculated as novel risk indicator. 106 patients underwent umbilical hernia repair (70 for uncomplicated and 36 for complicated hernia) as single procedure. The median size of the hernia sac was statistically significantly smaller in the uncomplicated group (30 mm, interquartile range (IQR) 20-49 vs. 50 mm, IQR 40-71, p = 0.037). The median size of the neck was not different between both groups (15 mm, IQR 11-29 vs. 16 mm, IQR 12-21, p = 0.44). The median HNR was smaller in the uncomplicated group (1.76, IQR 1.45-2.18 vs. 3.33, IQR 2.97-3.91, p = 0.00026). Based on ROC curve analysis (area under the curve: 0.9038), a cut-off value of 2.5 was associated with 91 % sensitivity and 84 % specificity. A novel predictive factor for complications related to umbilical hernia is proposed. The Hernia-Neck Ratio can easily be calculated. These results suggest that umbilical hernia with HNR >2.5 should be operated, irrespective of the presence of symptoms.

  20. Monorail snare technique for the recovery of stretched platinum coils: technical case report.

    PubMed

    Fiorella, David; Albuquerque, Felipe C; Deshmukh, Vivek R; McDougall, Cameron G

    2005-07-01

    Coil stretching represents a potentially hazardous technical complication not infrequently encountered during the embolization of cerebral aneurysms. Often, the stretched coil cannot be advanced into the aneurysm or withdrawn intact. The operator is then forced to attempt to retract the damaged coil, which may result in coil breakage, leaving behind a significant length of potentially thrombogenic stretched coil material within the parent vessel. To overcome this problem, we devised a technique to snare the distal, unstretched, intact portion of the platinum coil by use of the indwelling microcatheter and stretched portion of the coil as a monorail guide. We have used this technique successfully in four patients to snare coils stretched during cerebral aneurysm embolization. Three of these patients were undergoing Neuroform (Boston Scientific/Target, Fremont, CA) stent-supported coil embolization of unruptured aneurysms. In all cases, the snare was advanced easily to the targeted site for coil engagement by use of the microcatheter as a monorail guide. Once the intact distal segment of the coil was ensnared, coil removal was uneventful, with no disturbance of the remainder of the indwelling coil pack or Neuroform stent. A 2-mm Amplatz Goose Neck microsnare (Microvena Corp., White Bear Lake, MN) was placed through a Prowler-14 microcatheter (Cordis Corp., Miami, FL). The hub of the indwelling SL-10 microcatheter (Boston Scientific, Natick, MA) was then cut away with a scalpel, leaving the coil pusher wire intact, and removed. The open 2-mm snare was then advanced over the outside of the coil pusher wire and microcatheter. The snare and Prowler-14 microcatheter were then advanced into the guiding catheter (6- or 7-French) as a unit over the indwelling SL-10 microcatheter. By use of the SL-10 microcatheter and coil as a "monorail" guide, the snare was advanced over and beyond the microcatheter and the stretched portion of the coil until the snare was in position to engage the distal unstretched coil. At this point, the snare was then closed around the intact portion of the coil, and the microcatheters, snare, and coil were removed as a unit. The monorail snare technique represents a fast, safe, and easy method by which a stretched coil can be removed.

  1. Comprehensive Survey on Improved Focality and Penetration Depth of Transcranial Magnetic Stimulation Employing Multi-Coil Arrays.

    PubMed

    Wei, Xile; Li, Yao; Lu, Meili; Wang, Jiang; Yi, Guosheng

    2017-11-14

    Multi-coil arrays applied in transcranial magnetic stimulation (TMS) are proposed to accurately stimulate brain tissues and modulate neural activities by an induced electric field (EF). Composed of numerous independently driven coils, a multi-coil array has alternative energizing strategies to evoke EFs targeting at different cerebral regions. To improve the locating resolution and the stimulating focality, we need to fully understand the variation properties of induced EFs and the quantitative control method of the spatial arrangement of activating coils, both of which unfortunately are still unclear. In this paper, a comprehensive analysis of EF properties was performed based on multi-coil arrays. Four types of planar multi-coil arrays were used to study the relationship between the spatial distribution of EFs and the structure of stimuli coils. By changing coil-driven strategies in a basic 16-coil array, we find that an EF induced by compactly distributed coils decays faster than that induced by dispersedly distributed coils, but the former has an advantage over the latter in terms of the activated brain volume. Simulation results also indicate that the attenuation rate of an EF induced by the 36-coil dense array is 3 times and 1.5 times greater than those induced by the 9-coil array and the 16-coil array, respectively. The EF evoked by the 36-coil dispense array has the slowest decay rate. This result demonstrates that larger multi-coil arrays, compared to smaller ones, activate deeper brain tissues at the expense of decreased focality. A further study on activating a specific field of a prescribed shape and size was conducted based on EF variation. Accurate target location was achieved with a 64-coil array 18 mm in diameter. A comparison between the figure-8 coil, the planar array, and the cap-formed array was made and demonstrates an improvement of multi-coil configurations in the penetration depth and the focality. These findings suggest that there is a tradeoff between attenuation rate and focality in the application of multi-coil arrays. Coil-energizing strategies and array dimensions should be based on an adequate evaluation of these two important demands and the topological structure of target tissues.

  2. Designed Coiled-Coil Peptides Inhibit the Type Three Secretion System of Enteropathogenic Escherichia coli

    PubMed Central

    Larzábal, Mariano; Mercado, Elsa C.; Vilte, Daniel A.; Salazar-González, Hector; Cataldi, Angel; Navarro-Garcia, Fernando

    2010-01-01

    Background Enteropathogenic E. coli (EPEC) and enterohemorrhagic E. coli (EHEC) are two categories of E. coli strains associated with human disease. A major virulence factor of both pathotypes is the expression of a type three secretion system (TTSS), responsible for their ability to adhere to gut mucosa causing a characteristic attaching and effacing lesion (A/E). The TTSS translocates effector proteins directly into the host cell that subvert mammalian cell biochemistry. Methods/Principal Findings We examined synthetic peptides designed to inhibit the TTSS. CoilA and CoilB peptides, both representing coiled-coil regions of the translocator protein EspA, and CoilD peptide, corresponding to a coiled–coil region of the needle protein EscF, were effective in inhibiting the TTSS dependent hemolysis of red blood cells by the EPEC E2348/69 strain. CoilA and CoilB peptides also reduced the formation of actin pedestals by the same strain in HEp-2 cells and impaired the TTSS-mediated protein translocation into the epithelial cell. Interestingly, CoilA and CoilB were able to block EspA assembly, destabilizing the TTSS and thereby Tir translocation. This blockage of EspA polymerization by CoilA or CoilB peptides, also inhibited the correct delivery of EspB and EspD as detected by immunoblotting. Interestingly, electron microscopy of bacteria incubated with the CoilA peptide showed a reduction of the length of EspA filaments. Conclusions Our data indicate that coiled-coil peptides can prevent the assembly and thus the functionality of the TTSS apparatus and suggest that these peptides could provide an attractive tool to block EPEC and EHEC pathogenesis. PMID:20140230

  3. Embolization of the Gastroduodenal Artery Before Selective Internal Radiotherapy: A Prospectively Randomized Trial Comparing Standard Pushable Coils with Fibered Interlock Detachable Coils

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dudeck, Oliver, E-mail: oliver.dudeck@med.ovgu.de; Bulla, Karsten; Wieners, Gero

    2011-02-15

    The purpose of this study was compare embolization of the gastroduodenal artery (GDA) using standard pushable coils with the Interlock detachable coil (IDC), a novel fibered mechanically detachable long microcoil, in patients scheduled for selective internal radiotherapy (SIRT). Fifty patients (31 male and 19 female; median age 66.6 {+-} 8.1 years) were prospectively randomized for embolization using either standard coils or IDCs. Procedure time, radiation dose, number of embolization devices, complications, and durability of vessel occlusion at follow-up angiography were recorded. The procedures differed significantly in time (14:32 {+-} 5:56 min for standard coils vs. 2:13 {+-} 1:04 min formore » IDCs; p < 0.001); radiation dose for coil deployment (2479 {+-} 1237 cGycm Superscript-Two for standard coils vs. 275 {+-} 268 cGycm Superscript-Two for IDCs; p < 0.001); and vessel occlusion (17:18 {+-} 6:39 min for standard coils vs. 11:19 {+-} 7:54 min for IDCs; p = 0.002). A mean of 6.2 {+-} 1.8 coils (n = 27) were used in the standard coil group, and 1.3 {+-} 0.9 coils (p < 0.0001) were used in the IDC group (n = 23) because additional pushable coils were required to achieve GDA occlusion in 4 patients. In 2 patients, the IDC could not be deployed through a Soft-VU catheter. One standard coil dislodged in the hepatic artery and was retrieved. Vessel reperfusion was noted in only 1 patient in the standard coil group. Controlled embolization of the GDA with fibered IDCs was achieved more rapidly than with pushable coils. However, vessel occlusion may not be obtained using a single device only, and the use of sharply angled guiding catheters hampered coil pushability.« less

  4. Kinetic studies on strand displacement in de novo designed parallel heterodimeric coiled coils† †Electronic supplementary information (ESI) available. See DOI: 10.1039/c7sc05342h

    PubMed Central

    Groth, Mike C.; Rink, W. Mathis; Meyer, Nils F.

    2018-01-01

    Among the protein folding motifs, which are accessible by de novo design, the parallel heterodimeric coiled coil is most frequently used in bioinspired applications and chemical biology in general. This is due to the straightforward sequence-to-structure relationships, which it has in common with all coiled-coil motifs, and the heterospecificity, which allows control of association. Whereas much focus was laid on designing orthogonal coiled coils, systematic studies on controlling association, for instance by strand displacement, are rare. As a contribution to the design of dynamic coiled-coil-based systems, we studied the strand-displacement mechanism in obligate heterodimeric coiled coils to investigate the suitability of the dissociation constants (KD) as parameters for the prediction of the outcome of strand-displacement reactions. We use two sets of heterodimeric coiled coils, the previously reported N-AxBy and the newly characterized C-AxBy. Both comprise KD values in the μM to sub-nM regime. Strand displacement is explored by CD titration and a FRET-based kinetic assay and is proved to be an equilibrium reaction with half-lifes from a few seconds up to minutes. We could fit the displacement data by a competitive binding model, giving rate constants and overall affinities of the underlying association and dissociation reactions. The overall affinities correlate well with the ratios of KD values determined by CD-thermal denaturation experiments and, hence, support the dissociative mechanism of strand displacement in heterodimeric coiled coils. From the results of more than 100 different displacement reactions we are able to classify three categories of overall affinities, which allow for easy prediction of the equilibrium of strand displacement in two competing heterodimeric coiled coils. PMID:29780562

  5. Comparison of pelvic phased-array versus endorectal coil magnetic resonance imaging at 3 Tesla for local staging of prostate cancer.

    PubMed

    Kim, Bum Soo; Kim, Tae-Hwan; Kwon, Tae Gyun; Yoo, Eun Sang

    2012-05-01

    Several studies have demonstrated the superiority of endorectal coil magnetic resonance imaging (MRI) over pelvic phased-array coil MRI at 1.5 Tesla for local staging of prostate cancer. However, few have studied which evaluation is more accurate at 3 Tesla MRI. In this study, we compared the accuracy of local staging of prostate cancer using pelvic phased-array coil or endorectal coil MRI at 3 Tesla. Between January 2005 and May 2010, 151 patients underwent radical prostatectomy. All patients were evaluated with either pelvic phased-array coil or endorectal coil prostate MRI prior to surgery (63 endorectal coils and 88 pelvic phased-array coils). Tumor stage based on MRI was compared with pathologic stage. We calculated the specificity, sensitivity and accuracy of each group in the evaluation of extracapsular extension and seminal vesicle invasion. Both endorectal coil and pelvic phased-array coil MRI achieved high specificity, low sensitivity and moderate accuracy for the detection of extracapsular extension and seminal vesicle invasion. There were statistically no differences in specificity, sensitivity and accuracy between the two groups. Overall staging accuracy, sensitivity and specificity were not significantly different between endorectal coil and pelvic phased-array coil MRI.

  6. A history of detachable coils: 1987-2012.

    PubMed

    Hui, Ferdinand K; Fiorella, David; Masaryk, Thomas J; Rasmussen, Peter A; Dion, Jacques E

    2014-03-01

    The development of detachable coils is one of the most pivotal developments in neurointervention, providing a tool that could be used to treat a wide variety of hemorrhagic stroke. From the original Guglielmi detachable coil, a number of different coil designs and delivery designs have evolved. This article reviews the history of commercially available detachable coils. A timeline of detachable coils was constructed and coil design philosophies were reviewed. A complete list of commercially available coils is presented in a timeline format. Detachable coil technology continues to evolve. Advances in construction and design have yielded products which may benefit patients in terms of safety, radiation dose reduction and cost of treatment. Continued evolution is expected, irrespective of competing disruptive technologies.

  7. Evaluation of hyaluronan from different sources: Streptococcus zooepidemicus, rooster comb, bovine vitreous, and human umbilical cord.

    PubMed

    Shiedlin, Aviva; Bigelow, Russell; Christopher, William; Arbabi, Saman; Yang, Laura; Maier, Ronald V; Wainwright, Norman; Childs, Alice; Miller, Robert J

    2004-01-01

    Sodium hyaluronate (HA) is widely distributed in extracellular matrixes and can play a role in orchestrating cell function. Consequently, many investigators have looked at the effect of exogenous HA on cell behavior in vitro. HA can be isolated from several sources (e.g., bacterial, rooster comb, umbilical cord) and therefore can possess diverse impurities. This current study compares the measured impurities and the differences in biological activity between HA preparations from these sources. It was demonstrated that nucleic acid and protein content was highest in human umbilical cord and bovine vitreous HA and was low in bacterial and rooster comb HA. Macrophages exposed to human umbilical cord HA produced significantly higher amounts of TNF-alpha relative to control or bacterial-derived HA. These results indicate that the source of HA should be considered due to differences in the amounts and types of contaminants that could lead to widely different behaviors in vitro and in vivo.

  8. Armored umbilical apparatus for towing a marine seismic air gun sub array

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Burrage, E.C.

    1985-06-25

    An armored umbilical and termination housing is disclosed for towing a sub-array of seismic air guns used in marine seismic surveying comprising a single air hose for supplying all the high pressure air to the individual air guns surrounded by all the electrical control cables needed to operate the air guns in the sub-array. Protective coatings are applied around the electrical control cables and stress members for carrying the load of towing the sub-array are incorporated within the umbilical. A termination housing is provided on the end of the umbilical for terminating the single air hose and all the electricalmore » control lines to common connectors so that individual electrical control lines and air hoses can run from the termination housing to each individual air gun in the sub-array. Air shut off valves are provided so that the high pressure air can be shut off to the individual air guns within the sub-array remotely from the survey vessel.« less

  9. KSC-2014-3662

    NASA Image and Video Library

    2014-08-25

    CAPE CANAVERAL, Fla. – The umbilical swing arm for Orion's Exploration Flight Test 1, or EFT-1, has been attached to the uppermost location on the fixed umbilical tower at Space Launch Complex 37 at Cape Canaveral Air Force Station in Florida. All three swing arms on the tower are undergoing tests to confirm that they are operating correctly. The uppermost swing arm will carry umbilicals that will be mated to Orion's launch abort system and environmental control system. During launch, all three umbilicals will pull away from Orion and the United Launch Alliance Delta IV Heavy rocket at T-0. During the EFT-1 mission, Orion will travel farther into space than any human spacecraft has gone in more than 40 years. The data gathered during the flight will influence design decisions, validate existing computer models and innovative new approaches to space systems development, as well as reduce overall mission risks and costs for later Orion flights. Liftoff of Orion on its first flight test is planned for fall 2014. Photo credit: NASA/Daniel Casper

  10. KSC-2014-3660

    NASA Image and Video Library

    2014-08-25

    CAPE CANAVERAL, Fla. – The umbilical swing arm for Orion's Exploration Flight Test 1, or EFT-1, has been attached to the uppermost location on the fixed umbilical tower at Space Launch Complex 37 at Cape Canaveral Air Force Station in Florida. All three swing arms on the tower will undergo tests to confirm that they are operating correctly. The uppermost swing arm will carry umbilicals that will be mated to Orion's launch abort system and environmental control system. During launch, all three umbilicals will pull away from Orion and the United Launch Alliance Delta IV Heavy rocket at T-0. During the EFT-1 mission, Orion will travel farther into space than any human spacecraft has gone in more than 40 years. The data gathered during the flight will influence design decisions, validate existing computer models and innovative new approaches to space systems development, as well as reduce overall mission risks and costs for later Orion flights. Liftoff of Orion on its first flight test is planned for fall 2014. Photo credit: NASA/Daniel Casper

  11. KSC-2014-3661

    NASA Image and Video Library

    2014-08-25

    CAPE CANAVERAL, Fla. – The umbilical swing arm for Orion's Exploration Flight Test 1, or EFT-1, has been attached to the uppermost location on the fixed umbilical tower at Space Launch Complex 37 at Cape Canaveral Air Force Station in Florida. All three swing arms on the tower will undergo tests to confirm that they are operating correctly. The uppermost swing arm will carry umbilicals that will be mated to Orion's launch abort system and environmental control system. During launch, all three umbilicals will pull away from Orion and the United Launch Alliance Delta IV Heavy rocket at T-0. During the EFT-1 mission, Orion will travel farther into space than any human spacecraft has gone in more than 40 years. The data gathered during the flight will influence design decisions, validate existing computer models and innovative new approaches to space systems development, as well as reduce overall mission risks and costs for later Orion flights. Liftoff of Orion on its first flight test is planned for fall 2014. Photo credit: NASA/Daniel Casper

  12. The Usefulness of Patch Repair Using the Repermeabilized Umbilical Vein of the Round Ligament for Hepatobiliary Malignancies.

    PubMed

    Takahashi, Michiro; Saiura, Akio; Takahashi, Yu

    2017-11-01

    Patients with tumors invading major veins may require combined resection and reconstruction. However, venous reconstruction often demands complex hepatobiliary and vascular surgical procedures. In this study, we report a simple patch repair technique for venous reconstruction using the repermeabilized umbilical vein of the round ligament. We reviewed the outcomes of eleven patients who underwent venous wedge resection and patch repair using the repermeabilized umbilical vein of the round ligament at our institution. Procurement of the round ligament and method of making a patch is simple. The duration of anastomosis was approximately 15 min. Eight patients (73%) underwent hepatic resection followed by hepatic vein reconstruction; two (18%) pancreaticoduodenectomy followed by inferior vena cava (IVC) reconstruction; one (9%) hepatic resection followed by IVC reconstruction. Although one reconstructed vein became narrowed, the other ten veins were patent after surgery. Patch repair using the repermeabilized umbilical vein of the round ligament is a simple and useful technique.

  13. Laparoscopic umbilical hernia repair in a cirrhotic patient with a peritoneovenous shunt.

    PubMed

    Umemura, Akira; Suto, Takayuki; Sasaki, Akira; Fujita, Tomohiro; Endo, Fumitaka; Wakabayashi, Go

    2015-05-01

    A 62-year-old Japanese woman who had developed massive cirrhotic ascites was referred to our hospital for a peritoneovenous shunt implant. However, CT examination revealed an umbilical hernia that had not been observed before the peritoneovenous shunt was implanted. We decided to perform laparoscopic umbilical hernia repair to keep carbon dioxide from flowing backward into the central circulatory system. We first clamped the catheter and set the upper limit of the pneumoperitoneum pressure to 6 mmHg. The central venous pressure was also measured simultaneously. Mesh was then applied over the hernia and fixed by the double-crown technique. Finally, 1000-mL physiological saline was infused into the abdominal cavity while the pneumoperitoneum was slowly released. In this case, we safely performed laparoscopic umbilical hernia repair while making some alterations, specifically catheter clamping, reducing pneumoperitoneum pressure, monitoring central venous pressure, and infusing physiological saline. © 2014 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and Wiley Publishing Asia Pty Ltd.

  14. Radio frequency coil technology for small-animal MRI.

    PubMed

    Doty, F David; Entzminger, George; Kulkarni, Jatin; Pamarthy, Kranti; Staab, John P

    2007-05-01

    A review of the theory, technology, and use of radio frequency (RF) coils for small-animal MRI is presented. It includes a brief overview of MR signal-to-noise (S/N) analysis and discussions of the various coils commonly used in small-animal MR: surface coils, linear volume coils, birdcages, and their derivatives. The scope is limited to mid-range coils, i.e. coils where the product (fd) of the frequency f and the coil diameter d is in the range 2-30 MHz-m. Common applications include mouse brain and body coils from 125 to 750 MHz, rat body coils up to 500 MHz, and small surface coils at all fields. In this regime, all the sources of loss (coil, capacitor, sample, shield, and transmission lines) are important. All such losses may be accurately captured in some modern full-wave 3D electromagnetics software, and new simulation results are presented for a selection of surface coils using Microwave Studio 2006 by Computer Simulation Technology, showing the dramatic importance of the "lift-off effect". Standard linear circuit simulators have been shown to be useful in optimization of complex coil tuning and matching circuits. There appears to be considerable potential for trading S/N for speed using phased arrays, especially for a larger field of view. Circuit simulators are shown to be useful for optimal mismatching of ultra-low-noise preamps based on the enhancement-mode pseudomorphic high-electron-mobility transistor for optimal coil decoupling in phased arrays. Cryogenically cooled RF coils are shown to offer considerable opportunity for future gains in S/N in smaller samples.

  15. Can flavonoid-rich chocolate modulate arterial elasticity and pathological uterine artery Doppler blood flow in pregnant women? A pilot study.

    PubMed

    von Wowern, Emma; Olofsson, Per

    2018-09-01

    Dark chocolate has shown beneficial effects on cardiovascular health and might also modulate hypertensive complications in pregnancy and uteroplacental blood flow. Increased uteroplacental resistance is associated with systemic arterial stiffness. We aimed to investigate the short-term effect of flavonoid-rich chocolate on arterial stiffness and Doppler blood flow velocimetry indexes in pregnant women with compromised uteroplacental blood flow. Doppler blood flow velocimetry and digital pulse wave analysis (DPA) were performed in 25 women pregnant in the second and third trimesters with uterine artery (UtA) score (UAS) 3-4, before and after 3 days of ingestion of chocolate with high flavonoid and antioxidant contents. UtA pulsatility index (PI), UtA diastolic notching, UAS (semiquantitative measure of PI and notching combined), and umbilical artery PI were calculated, and DPA variables representing central and peripheral maternal arteries were recorded. Mean UtA PI (p = .049) and UAS (p = .025) significantly decreased after chocolate consumption. There were no significant changes in UtA diastolic notching or any DPA indexes of arterial stiffness/vascular tone. Chocolate may have beneficial effects on the uteroplacental circulation, but in this pilot study, we could not demonstrate effects on arterial vascular tone as assessed by DPA.

  16. A Synthetic Coiled-Coil Interactome Provides Heterospecific Modules for Molecular Engineering

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reinke, Aaron W.; Grant, Robert A.; Keating, Amy E.

    2010-06-21

    The versatile coiled-coil protein motif is widely used to induce and control macromolecular interactions in biology and materials science. Yet the types of interaction patterns that can be constructed using known coiled coils are limited. Here we greatly expand the coiled-coil toolkit by measuring the complete pairwise interactions of 48 synthetic coiled coils and 7 human bZIP coiled coils using peptide microarrays. The resulting 55-member protein 'interactome' includes 27 pairs of interacting peptides that preferentially heteroassociate. The 27 pairs can be used in combinations to assemble sets of 3 to 6 proteins that compose networks of varying topologies. Of specialmore » interest are heterospecific peptide pairs that participate in mutually orthogonal interactions. Such pairs provide the opportunity to dimerize two separate molecular systems without undesired crosstalk. Solution and structural characterization of two such sets of orthogonal heterodimers provide details of their interaction geometries. The orthogonal pair, along with the many other network motifs discovered in our screen, provide new capabilities for synthetic biology and other applications.« less

  17. Measurement of a Conduction Cooled Nb3Sn Racetrack Coil

    NASA Astrophysics Data System (ADS)

    Kim, HS; Kovacs, C.; Rochester, J.; Sumption, MD; Tomsic, M.; Peng, X.; Doll, D.

    2017-12-01

    Use of superconducting coils for wind turbines and electric aircraft is of interest because of the potential for high power density and weight reduction. Here we test a racetrack coil developed as a proof-of-concept for cryogen-free superconducting motors and generators. The coil was wound with 1209 m of 0.7-mm-diameter insulated tube-type Nb3Sn wire. The coil was epoxy-impregnated, instrumented, covered with numerous layers of aluminized mylar insulation, and inserted vertically into a dewar. The system was cooled to 4.2 K, and a few inches of liquid helium was allowed to collect at the bottom of the dewar but below the coil. The coil was cooled by conduction via copper cooling bars were attached to the coil but also were immersed in the liquid helium at their lower ends. Several current tests were performed on the coil, initially in voltage mode, and one run in current mode. The maximum coil Ic at 4.2 K was 480 A, generating 3.06 T at the surface of the coil. The coil met the design targets with a noticeable margin.

  18. Measurement of Diffusion in Entangled Rod-Coil Triblock Copolymers

    NASA Astrophysics Data System (ADS)

    Olsen, B. D.; Wang, M.

    2012-02-01

    Although rod-coil block copolymers have attracted increasing attention for functional nanomaterials, their dynamics relevant to self-assembly and processing have not been widely investigated. Because the rod and coil blocks have different reptation behavior and persistence lengths, the mechanism by which block copolymers will diffuse is unclear. In order to understand the effect of the rigid block on reptation, tracer diffusion of a coil-rod-coil block copolymer through an entangled coil polymer matrix was experimentally measured. A monodisperse, high molecular weight coil-rod-coil triblock was synthesized using artificial protein engineering to prepare the helical rod and bioconjugaiton of poly(ethylene glycol) coils to produce the final triblock. Diffusion measurements were performed using Forced Rayleigh scattering (FRS), at varying ratios of the rod length to entanglement length, where genetic engineering is used to control the protein rod length and the polymer matrix concentration controls the entanglement length. As compared to PEO homopolymer tracers, the coil-rod-coil triblocks show markedly slower diffusion, suggesting that the mismatch between rod and coil reptation mechanisms results in hindered diffusion of these molecules in the entangled state.

  19. Deep brain transcranial magnetic stimulation using variable "Halo coil" system

    NASA Astrophysics Data System (ADS)

    Meng, Y.; Hadimani, R. L.; Crowther, L. J.; Xu, Z.; Qu, J.; Jiles, D. C.

    2015-05-01

    Transcranial Magnetic Stimulation has the potential to treat various neurological disorders non-invasively and safely. The "Halo coil" configuration can stimulate deeper regions of the brain with lower surface to deep-brain field ratio compared to other coil configurations. The existing "Halo coil" configuration is fixed and is limited in varying the site of stimulation in the brain. We have developed a new system based on the current "Halo coil" design along with a graphical user interface system that enables the larger coil to rotate along the transverse plane. The new system can also enable vertical movement of larger coil. Thus, this adjustable "Halo coil" configuration can stimulate different regions of the brain by adjusting the position and orientation of the larger coil on the head. We have calculated magnetic and electric fields inside a MRI-derived heterogeneous head model for various positions and orientations of the coil. We have also investigated the mechanical and thermal stability of the adjustable "Halo coil" configuration for various positions and orientations of the coil to ensure safe operation of the system.

  20. The accommodation index measures the perturbation associated with insertions and deletions in coiled‐coils: Application to understand signaling in histidine kinases

    PubMed Central

    Schmidt, Nathan W.; Grigoryan, Gevorg

    2017-01-01

    Abstract Coiled‐coils are essential components of many protein complexes. First discovered in structural proteins such as keratins, they have since been found to figure largely in the assembly and dynamics required for diverse functions, including membrane fusion, signal transduction and motors. Coiled‐coils have a characteristic repeating seven‐residue geometric and sequence motif, which is sometimes interrupted by the insertion of one or more residues. Such insertions are often highly conserved and critical to interdomain communication in signaling proteins such as bacterial histidine kinases. Here we develop the “accommodation index” as a parameter that allows automatic detection and classification of insertions based on the three dimensional structure of a protein. This method allows precise identification of the type of insertion and the “accommodation length” over which the insertion is structurally accommodated. A simple theory is presented that predicts the structural perturbations of 1, 3, 4 residue insertions as a function of the length over which the insertion is accommodated. Analysis of experimental structures is in good agreement with theory, and shows that short accommodation lengths give rise to greater perturbation of helix packing angles, changes in local helical phase, and increased structural asymmetry relative to long accommodation lengths. Cytoplasmic domains of histidine kinases in different signaling states display large changes in their accommodation lengths, which can now be seen to underlie diverse structural transitions including symmetry/asymmetry and local variations in helical phase that accompany signal transduction. PMID:27977891

  1. Safety and effectiveness of umbilical hernia repair in patients with cirrhosis.

    PubMed

    Hew, S; Yu, W; Robson, S; Starkey, G; Testro, A; Fink, M; Angus, P; Gow, P

    2018-03-27

    Umbilical hernia is a common complication in patients with cirrhosis. Early studies have reported a high morbidity and mortality associated with hernia repair. The traditional approach has been to non-operatively manage umbilical hernias in patients with cirrhosis. There are emerging data suggesting that an elective repair is a preferable approach. This study examined the outcomes of umbilical hernia repair in patients with advanced liver disease and compared this with a control group of non-cirrhotic patients. Prospective data were collected regarding the outcome of umbilical hernia repairs performed between 2004 and 2013 at the Austin Hospital, Melbourne, Australia. Outcomes at 90 days were compared between patients with and without cirrhosis. 79 patients with cirrhosis and 249 controls were analysed. Of the patients with cirrhosis, 9% were classified as Child-Pugh A, 61% were Child-Pugh B and 30% were Child-Pugh C. Emergency repairs for complicated hernias was undertaken in 18% of the cirrhosis population and 10% in controls (P = 0.10). Post-operative complications occurred more commonly in patients with cirrhosis (26%) compared with controls (11%) (P < 0.01). Emergency hernia repairs were associated with a higher complication rate in both patients with cirrhosis (62%) and controls (20%) (P = 0.01). There was no significant difference in the rate of hernia recurrence as assessed by clinical examination between patients with cirrhosis (2.7%) and controls (6.8%) (P = 0.17) nor in 90-day mortality between patients with cirrhosis (n = 1, 1.3%) and the controls (n = 0) (P = 0.43). Within the limitations of a small study cohort and therefore an underpowered study, elective surgical repair of umbilical hernias in patients with cirrhosis, including decompensated cirrhosis, may not be associated with a significant increase in mortality when compared to a control cohort. Whilst complications are higher in cirrhotic patients, there is no difference in the rate of hernia recurrence. Emergency repairs of umbilical hernias are associated with a high complication rate in cirrhotic patients.

  2. Apparatus for unilateral generation of a homogeneous magnetic field

    DOEpatents

    Fukushima, Eiichi; Rath, Alan R.; Roeder, Stephen B. W.

    1988-01-01

    An apparatus for unilaterally producing a substantially homogeneous magnetic field. The apparatus includes two circular electromagnet coils, a small coil and a large coil, which are coaxial with one another and which are separated by a distance equal to one-half the difference in the radius of the two coils. By appropriate selection of electrical currents, which are passed through the coil in opposite directions, a region of homogeneous magnetic field is formed. This region is centered on the common axis of the two coils, at a point on the axis which is at a distance from the small coil equal to one-half the radius of the small coil, and which is on the opposite side of the small coil from the large coil. The apparatus has particular application in the field of diagnostic medical NMR and other NMR applications.

  3. Apparatus for unilateral generation of a homogeneous magnetic field

    DOEpatents

    Fukushima, E.; Rath, A.R.; Roeder, S.B.W.

    1984-05-01

    An apparatus for unilaterally producing a substantially homogeneous magnetic field. The apparatus includes two circular electromagnet coils, a small coil and a large coil, which are coaxial with one another and which are separated by a distance equal to one-half the difference in the radius of the two coils. By appropriate selection of electrical currents, which are passed through the coils in opposite directions, a region of homogeneous magnetic field is formed. This region is centered on the common axis of the two coils, at a point on the axis which is at a distance from the small coil equal to one-half the radius of the small coil, and which is on the opposite side of the small coil from the large coil. The apparatus has particular application in the field of diagnostic medical NMR and other NMR applications.

  4. Aneurysm permeability following coil embolization: packing density and coil distribution.

    PubMed

    Chueh, Ju-Yu; Vedantham, Srinivasan; Wakhloo, Ajay K; Carniato, Sarena L; Puri, Ajit S; Bzura, Conrad; Coffin, Spencer; Bogdanov, Alexei A; Gounis, Matthew J

    2015-09-01

    Rates of durable aneurysm occlusion following coil embolization vary widely, and a better understanding of coil mass mechanics is desired. The goal of this study is to evaluate the impact of packing density and coil uniformity on aneurysm permeability. Aneurysm models were coiled using either Guglielmi detachable coils or Target coils. The permeability was assessed by taking the ratio of microspheres passing through the coil mass to those in the working fluid. Aneurysms containing coil masses were sectioned for image analysis to determine surface area fraction and coil uniformity. All aneurysms were coiled to a packing density of at least 27%. Packing density, surface area fraction of the dome and neck, and uniformity of the dome were significantly correlated (p<0.05). Hence, multivariate principal components-based partial least squares regression models were used to predict permeability. Similar loading vectors were obtained for packing and uniformity measures. Coil mass permeability was modeled better with the inclusion of packing and uniformity measures of the dome (r(2)=0.73) than with packing density alone (r(2)=0.45). The analysis indicates the importance of including a uniformity measure for coil distribution in the dome along with packing measures. A densely packed aneurysm with a high degree of coil mass uniformity will reduce permeability. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  5. Radio-frequency coil selection for MR imaging of the carotid vessel wall

    NASA Astrophysics Data System (ADS)

    Mat Isa, S.; Shuaib, I. L.; Bauk, S.

    2014-11-01

    This aim of this study was to identify the radiofrequency coil that will produce optimum image quality for scanning the carotid vessel wall using magnetic resonance imaging. A comparative cross-sectional study was conducted using 10 volunteers. Each volunteer was scanned three times using a 1.5T Signa HDxt machine equipped with one of three different coils: a neurovascular array (NV) coil, an 8-channel CTL spine array coil, and a 3-inch surface coil. A qualitative image quality rating was assigned to each image. The images were also evaluated by measuring the signal to noise ratio (SNR) using Osirix 4.2.3 software. The noise was estimated from the mean intensities of the region of interest in the background of the images and the signal was measured in the muscle adjacent to the vessel wall. The SNRs of the three coils were compared using one-way ANOVA, with 104 images used for the data analysis. The mean image quality scores for the NV head coil, CTL coil, and 3-inch coil were 3.4, 3.33, and 1.67, respectively. In addition, the SNRs differed significantly (p < 0.05). The mean SNR for the 3-inch coil was significantly higher (56.21 ± 25.06) than those for the NV head coil (27.34 ± 15.47) and CTL coil (21.77 ± 13.14). The Bonferroni post-hoc test revealed that there was no significant difference between the NV head coil and the CTL coil (p = 0.21). The optimum SNR value was 20-27. These results indicate that the NV head coil and CTL coil can be used to evaluate the carotid arterial wall with optimum image quality and higher resolution. These coil can deliver fast and robust data to image the carotid vessel wall in vivo.

  6. Application of a run around coil system to a roof fan house at Michoud Assembly Facility at New Orleans, Louisiana

    NASA Technical Reports Server (NTRS)

    1976-01-01

    Analysis of the proposed run around coil system indicates that it offers a decrease in steam, electricity and water consumptions. The run around coil system consist of two coils, a precooling coil which will be located at up stream and a reheating coil which will be located at down stream of the chilled water spray chamber. This system will provide the necessary reheat in summer, spring and fall. At times, if the run around coil system can not provide the necessary reheat, the existing reheat coil could be utilized.

  7. Hepatic laceration because of malpositioning of the umbilical vein catheter: case report and literature review.

    PubMed

    Yiğiter, Murat; Arda, Irfan Serdar; Hiçsönmez, Akgün

    2008-05-01

    Umbilical vein catheterization that is a common bedside procedure in the neonatal intensive care units is not without complication. The most common complications are thrombus formation, embolism, vessel perforation, hemorrhage, and infection. Complications related to the liver carry a high risk for mortality. Laceration is an ominous complication of umbilical vein catheter that is generally a result of direct injury through the liver parenchyma. Abdominal distension that develops gradually should alert the physician for a likely development of intrahepatic bleeding. Surgery is mandatory in patients with ongoing bleeding after the withdrawal of the catheter. Early diagnosis and treatment are lifesaving in these patients.

  8. Tail Service Mast Umbilical Arrival

    NASA Image and Video Library

    2016-08-02

    A crane lowers the first Tail Service Mast Umbilical (TSMU) onto a test stand at the Launch Equipment Test Facility at NASA’s Kennedy Space Center in Florida. Two TSMUs will provide liquid propellants and power to the Space Launch System (SLS) rocket’s core stage engine. Both TSMUs will connect to the zero-level deck on the mobile launcher, providing fuel and electricity to the SLS rocket before it launches on Exploration Mission 1. The TSMU will undergo testing and validation at the LETF to verify it is functioning properly. The center’s Engineering Directorate and the Ground Systems Development and Operations Program are overseeing processing and testing of the umbilicals.

  9. Patent vitellointestinal duct as paraumblical abcess: A rare presentation

    PubMed Central

    Rekhi, Harnam Singh; Mittal, Sushil; Singh, Gurtej; Rekhi, Balwinder Kaur; Dugg, Pankaj

    2015-01-01

    Introduction Umbilical and paraumblical abscess can occur in children with presenting complaint of discharge from umbilical region. However, patent vitello intestinal duct presenting as paraumblical abscess is rare phenomenon. Presentation of case One year old male child presented with complain of discharge from umbilical region since birth. Incision & drainage done twice thinking it to be paraumblical abscess. Discussion Vitellointestinal duct as abscess is rare presentation but it should be considered as a differential diagnosis of discharging umbilicus as management of abscess and patent duct are different. Conclusion Patent vitellointestinal duct can present as paraumbilical abscess, and it should be kept in differential diagnosis specifically in children. PMID:26301682

  10. Prenatal diagnosis of abnormal course of umbilical vein and ductus venosus agenesis: report of three cases.

    PubMed

    Corbacioglu, Aytul; Aslan, Halil; Dagdeviren, Hediye; Ceylan, Yavuz

    2012-01-01

    Ductus venosus connecting the portal and embryonic venous circulation into the inferior vena cava has a crucial role in fetal circulation. The absence of ductus venosus is a rare anomaly, in which the umbilical vein connection to the venous system may be extrahepatic, bypassing the liver or intrahepatic via the portal venous system. We report three cases of ductus venosus agenesis with associated anomalies. In two of them the connection was directly to the right atrium, whereas the umbilical vein drained to the left internal iliac artery in the third case. Copyright © 2012 Wiley Periodicals, Inc.

  11. Effective arrangement of separated transmit-only/receive-only RF coil for improvement of B1 homogeneity at 7 Tesla

    NASA Astrophysics Data System (ADS)

    Im, Geun Ho; Seo, Jeong-Hoon; Kim, Kyoung-Nam; Heo, Phil; Chung, Julius Juhyun; Jang, Moon-Sun; Lee, Jung Hee; Kim, Jae-Hun; Kim, Sun I.

    2014-09-01

    This article presents an effective arrangement with shifted transmit (Tx)-only and receive (Rx)-only (TORO) radiofrequency (RF) coils in a single-channel surface coil for improving the magnetic flux ( B 1) homogeneity in an ultra-high field (UHF) magnetic resonance imaging (MRI) scanner. The proposed new methodology for the coil arrangement using the shifted TORO RF coils was demonstrated for coils with 50-mm, 100-mm, and 150-mm-square surfaces and the results were compared to those for general Tx/Rx surface coils with the same dimensions. The computational analysis indicated that a homogeneous B1 field was achieved when the Rx-only coil was shifted in the two-dimensional xy-plane away from the Tx-only coils. Because the proposed coil configuration provides a unique opportunity for increasing the B 1 homogeneity, this feature is likely to increase the feasibility via new coil arrangements of UHF surface design and fabrication.

  12. New Side-Looking Rogowski Coil Sensor for Measuring Large-Magnitude Fast Impulse Currents

    NASA Astrophysics Data System (ADS)

    Metwally, I. A.

    2015-12-01

    This paper presents a new design of a side-looking "flat spiral" self-integrating Rogowski coil that is wound by twin coaxial cable with individual sheath. The coil is tested with different impulse current waveforms up to 7 kA peak value to improve its performance. The coil design is optimized to achieve bandwidth and sensitivity up to 7.854 MHz and 3.623 V/kA, respectively. The coil is calibrated versus two commercial impulse-current measurement devices at different coil-to-wire separations, coil inclination angles, and impulse current waveforms. Distortion of the coil output voltage waveform is examined by using the lumped-element model to optimize the connections of the four cable winding sheaths and the coil termination resistance. Finally, the coil frequency response is investigated to optimize the coil design parameters and achieve the desired bandwidth (large low-frequency time constant), high rate of rise, no overshoot, very small droop, high rate of fall, and no backswing.

  13. Apparatus and Methods for Mitigating Electromagnetic Emissions

    NASA Technical Reports Server (NTRS)

    Geng, Steven M. (Inventor); Niedra, Janis M. (Inventor)

    2013-01-01

    Apparatus, methods, and other embodiments associated with mitigation of magnetic fields are described herein. In an embodiment, a method for mitigating an electromagnetic field includes positioning a mitigating coil around a linear alternator of linear motor so that the mitigating coil is coaxially located with an alternator coil; arranging the mitigating coil to generate a field to mitigate an electromagnetic field generated by the alternator coil; and passing an induced current from the alternator coil through the mitigating coil.

  14. Apparatus and Methods for Mitigating Electromagnetic Emissions

    NASA Technical Reports Server (NTRS)

    Geng, Steven M. (Inventor); Niedra, Janis M. (Inventor)

    2016-01-01

    Apparatus, methods, and other embodiments associated with mitigation of magnetic fields are described herein. In an embodiment, a method for mitigating an electromagnetic field includes positioning a mitigating coil around a linear alternator of linear motor so that the mitigating coil is coaxially located with an alternator coil; arranging the mitigating coil to generate a field to mitigate an electromagnetic field generated by the alternator coil; and passing an induced current from the alternator coil through the mitigating coil.

  15. Optimization and Validation of Rotating Current Excitation with GMR Array Sensors for Riveted

    DTIC Science & Technology

    2016-09-16

    distribution. Simulation results, using both an optimized coil and a conventional coil, are generated using the finite element method (FEM) model...optimized coil and a conventional coil, are generated using the finite element method (FEM) model. The signal magnitude for an optimized coil is seen to be...optimized coil. 4. Model Based Performance Analysis A 3D finite element model (FEM) is used to analyze the performance of the optimized coil and

  16. CCBuilder: an interactive web-based tool for building, designing and assessing coiled-coil protein assemblies.

    PubMed

    Wood, Christopher W; Bruning, Marc; Ibarra, Amaurys Á; Bartlett, Gail J; Thomson, Andrew R; Sessions, Richard B; Brady, R Leo; Woolfson, Derek N

    2014-11-01

    The ability to accurately model protein structures at the atomistic level underpins efforts to understand protein folding, to engineer natural proteins predictably and to design proteins de novo. Homology-based methods are well established and produce impressive results. However, these are limited to structures presented by and resolved for natural proteins. Addressing this problem more widely and deriving truly ab initio models requires mathematical descriptions for protein folds; the means to decorate these with natural, engineered or de novo sequences; and methods to score the resulting models. We present CCBuilder, a web-based application that tackles the problem for a defined but large class of protein structure, the α-helical coiled coils. CCBuilder generates coiled-coil backbones, builds side chains onto these frameworks and provides a range of metrics to measure the quality of the models. Its straightforward graphical user interface provides broad functionality that allows users to build and assess models, in which helix geometry, coiled-coil architecture and topology and protein sequence can be varied rapidly. We demonstrate the utility of CCBuilder by assembling models for 653 coiled-coil structures from the PDB, which cover >96% of the known coiled-coil types, and by generating models for rarer and de novo coiled-coil structures. CCBuilder is freely available, without registration, at http://coiledcoils.chm.bris.ac.uk/app/cc_builder/. © The Author 2014. Published by Oxford University Press.

  17. A multi-slot surface coil for MRI of dual-rat imaging at 4 T

    NASA Astrophysics Data System (ADS)

    Solis, S. E.; Wang, R.; Tomasi, D.; Rodriguez, A. O.

    2011-06-01

    A slotted surface coil inspired by the hole-and-slot cavity magnetron was developed for magnetic resonance imaging of obese rats at 4 T. Full-wave analysis of the magnetic field was carried out at 170 MHz for both the slotted and circular-shaped coils. The noise figure values of two coils were investigated via the numerical calculation of the quality factors. Fat simulated phantoms to mimic overweight rats were included in the analysis with weights ranging from 300 to 900 g. The noise figures were 1.2 dB for the slotted coil and 2.4 dB for the circular coil when loaded with 600 g of simulated phantom. A slotted surface coil with eight circular slots and a circular coil with similar dimensions were built and operated in the transceiver mode, and their performances were experimentally compared. The imaging tests in phantoms demonstrated that the slotted surface coil has a deeper RF-sensitivity and better field uniformity than the single-loop RF-coil. High quality images of two overweight Zucker rats were acquired simultaneously with the slotted surface coil using standard spin-echo pulse sequences. Experimental results showed that the slotted surface coil outperformed the circular coil for imaging considerably overweight rats. Thus, the slotted surface coil can be a good tool for MRI experiments in rats on a human whole-body 4 T scanner.

  18. Shielded helix traveling wave cathode ray tube deflection structure

    DOEpatents

    Norris, Neil J.; Hudson, Charles L.

    1992-01-01

    Various embodiments of a helical coil deflection structure of a CRT are described and illustrated which provide shielding between adjacent turns of the coil on either three or four sides of each turn in the coil. Threaded members formed with either male or female threads and having the same pitch as the deflection coil are utilized for shielding the deflection coil with each turn of the helical coil placed between adjacent threads which act to shield each coil turn from adjacent turns and to confine the field generated by the coil to prevent or inhibit cross-coupling between adjacent turns of the coil to thereby prevent generation of fast fields which might otherwise deflect the beam out of time synchronization with the electron beam pulse.

  19. Design guidelines for an umbilical cord blood stem cell therapy quality assessment model

    NASA Astrophysics Data System (ADS)

    Januszewski, Witold S.; Michałek, Krzysztof; Yagensky, Oleksandr; Wardzińska, Marta

    The paper enlists the pivotal guidelines for producing an empirical umbilical cord blood stem cell therapy quality assessment model. The methodology adapted was single equation linear model with domain knowledge derived from MEDAFAR classification. The resulting model is ready for therapeutical application.

  20. 41. VIEW OF UMBILICAL MAST AND LAUNCH PAD FROM LAUNCHER; ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    41. VIEW OF UMBILICAL MAST AND LAUNCH PAD FROM LAUNCHER; SOUTH FACE OF MST IN BACKGROUND. RAIL SYSTEM FROM BASE OF MST PARALLEL TO MAST. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 East, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  1. Umbilical cannulation optimizes circuit flows in premature lambs supported by the EXTra-uterine Environment for Neonatal Development (EXTEND).

    PubMed

    Hornick, Matthew A; Davey, Marcus G; Partridge, Emily A; Mejaddam, Ali Y; McGovern, Patrick E; Olive, Aliza M; Hwang, Grace; Kim, Jenny; Castillo, Orlando; Young, Kathleen; Han, Jiancheng; Zhao, Sheng; Connelly, James T; Dysart, Kevin C; Rychik, Jack; Peranteau, William H; Flake, Alan W

    2018-05-01

    Bronchopulmonary dysplasia is a disease of extreme prematurity that occurs when the immature lung is exposed to gas ventilation. We designed a novel 'artificial womb' system for supporting extreme premature lambs (called EXTEND) that obviates gas ventilation by providing oxygen via a pumpless arteriovenous circuit with the lamb submerged in sterile artificial amniotic fluid. In the present study, we compare different arteriovenous cannulation strategies on EXTEND, including carotid artery/jugular vein (CA/JV), carotid artery/umbilical vein (CA/UV) and umbilical artery/umbilical vein (UA/UV). Compared to CA/JV and CA/UV cannulation, UA/UV cannulation provided significantly higher, physiological blood flows to the oxygenator, minimized flow interruptions and supported significantly longer circuit runs (up to 4 weeks). Physiological circuit blood flow in UA/UV lambs made possible normal levels of oxygen delivery, which is a critical step toward the clinical application of artificial womb technology. EXTEND (EXTra-uterine Environment for Neonatal Development) is a novel system that promotes physiological development by maintaining the premature lamb in a sterile fluid environment and providing gas exchange via a pumpless arteriovenous oxygenator circuit. During the development of EXTEND, different cannulation strategies evolved with the aim of improving circuit flow. The present study examines how different cannulation strategies affect EXTEND circuit haemodynamics in extreme premature lambs. Seventeen premature lambs were cannulated at gestational ages 105-117 days (term 145-150 days) and supported on EXTEND for up to 4 weeks. Experimental groups were distinguished by cannulation strategy: carotid artery outflow and jugular vein inflow (CA/JV; n = 4), carotid artery outflow and umbilical vein inflow (CA/UV; n = 5) and double umbilical artery outflow and umbilical vein inflow (UA/UV; n = 8). Circuit flows and pressures were measured continuously. As we transitioned from CA/JV to CA/UV to UA/UV cannulation, mean duration of circuit run and weight-adjusted circuit flows increased (P < 0.001) and the frequency of flow interruptions declined (P < 0.05). Umbilical vessels generally accommodated larger-bore cannulas, and cannula calibre was directly correlated with circuit pressures and indirectly correlated with flow:pressure ratio (a measure of post-membrane resistance). We conclude that UA/UV cannulation in fetal lambs on EXTEND optimizes circuit flow dynamics and flow stability and also supports circuit flows that closely approximate normal placental flow. © 2018 The Authors. The Journal of Physiology © 2018 The Physiological Society.

  2. Toroidal plasma response based ELM control coil design for EU DEMO

    NASA Astrophysics Data System (ADS)

    Zhou, Lina; Liu, Yueqiang; Wenninger, Ronald; Liu, Yue; Wang, Shuo; Yang, Xu

    2018-07-01

    Magnetic coil design study is carried out, for the purpose of mitigating or suppressing the edge localized modes (ELMs) in a EU DEMO reference scenario. The coil design, including both the coil geometry and the coil current requirement, is based on criteria derived from the linear, full toroidal plasma response computed by the MARS-F code (Liu et al 2000 Phys. Plasma 7 3681). With a single midplane row of coils, a coil size covering about 30°–50° poloidal angle of the torus is found to be optimal for ELM control using the n  >  2 resonant magnetic perturbation (RMP) field (n is the toroidal mode number). For off-midplane coils, the coils’ poloidal location, as well as the relative toroidal phase (coil phasing) between the upper and lower rows of coils, also sensitively affects the ELM control according to the specified criteria. Assuming that the optimal coil phasing can always be straightforwardly implemented, following a simple analytic model derived from toroidal computations, it is better to place the two off-midplane rows of coils near the midplane, in order to maximize the resonant field amplitude and to have larger effects on ELMs. With the same coil current, the ex-vessel coils can be made as effective as the in-vessel coils, at the expense of increasing the ex-vessel coils’ size. This is however possible only for low-n (n  =  1–3) RMP fields. With these low-n fields, and assuming 300 kAt maximal coil current, the computed plasma displacement near the X-point can meet the 10 mm level, which we use as the conservative indicator for achieving ELM mitigation in EU DEMO. The risk of partial control coil failure in EU DEMO is also assessed based on toroidal modeling, indicating that the large n  =  1 sideband due to coil failure may need to be corrected, if the nominal n  >  1 coil configurations are used for ELM control in EU DEMO.

  3. The contactless detection of local normal transitions in superconducting coils by using Poynting’s vector method

    NASA Astrophysics Data System (ADS)

    Habu, K.; Kaminohara, S.; Kimoto, T.; Kawagoe, A.; Sumiyoshi, F.; Okamoto, H.

    2010-11-01

    We have developed a new monitoring system to detect an unusual event in the superconducting coils without direct contact on the coils, using Poynting's vector method. In this system, the potential leads and pickup coils are set around the superconducting coils to measure local electric and magnetic fields, respectively. By measuring the sets of magnetic and electric fields, the Poynting's vectors around the coil can be obtained. An unusual event in the coil can be detected as the result of the change of the Poynting's vector. This system has no risk of the voltage breakdown which may happen with the balance voltage method, because there is no need of direct contacts on the coil windings. In a previous paper, we have demonstrated that our system can detect the normal transitions in the Bi-2223 coil without direct contact on the coil windings by using a small test system. For our system to be applied to practical devices, it is necessary for the early detection of an unusual event in the coils to be able to detect local normal transitions in the coils. The signal voltages of the small sensors to measure local magnetic and electric fields are small. Although the increase in signals of the pickup coils is attained easily by an increase in the number of turns of the pickup coils, an increase in the signals of the potential lead is not easily attained. In this paper, a new method to amplify the signal of local electric fields around the coil is proposed. The validity of the method has been confirmed by measuring local electric fields around the Bi-2223 coil.

  4. UV-activated 7-dehydrocholesterol-coated titanium implants promote differentiation of human umbilical cord mesenchymal stem cells into osteoblasts.

    PubMed

    Satué, María; Ramis, Joana M; Monjo, Marta

    2016-01-01

    Vitamin D metabolites are essential for bone regeneration and mineral homeostasis. The vitamin D precursor 7-dehydrocholesterol can be used after UV irradiation to locally produce active vitamin D by osteoblastic cells. Furthermore, UV-irradiated 7-dehydrocholesterol is a biocompatible coating for titanium implants with positive effects on osteoblast differentiation. In this study, we examined the impact of titanium implants surfaces coated with UV-irradiated 7-dehydrocholesterol on the osteogenic differentiation of human umbilical cord mesenchymal stem cells. First, the synthesis of cholecalciferol (D3) was achieved through the incubation of the UV-activated 7-dehydrocholesterol coating for 48 h at 23℃. Further, we investigated in vitro the biocompatibility of this coating in human umbilical cord mesenchymal stem cells and its potential to enhance their differentiation towards the osteogenic lineage. Human umbilical cord mesenchymal stem cells cultured onto UV-irradiated 7-dehydrocholesterol-coated titanium implants surfaces, combined with osteogenic supplements, upregulated the gene expression of several osteogenic markers and showed higher alkaline phosphatase activity and calcein blue staining, suggesting increased mineralization. Thus, our results show that the use of UV irradiation on 7-dehydrocholesterol -treated titanium implants surfaces generates a bioactive coating that promotes the osteogenic differentiation of human umbilical cord mesenchymal stem cells, with regenerative potential for improving osseointegration in titanium-based bone anchored implants. © The Author(s) 2015.

  5. Quantitative determination of famotidine in human maternal plasma, umbilical cord plasma and urine using high-performance liquid chromatography - mass spectrometry

    PubMed Central

    Wang, Xiaoming; Rytting, Erik; Abdelrahman, Doaa R.; Nanovskaya, Tatiana N.; Hankins, Gary D.V.; Ahmed, Mahmoud S.

    2013-01-01

    The liquid chromatography with electrospray ionization mass spectrometry for the quantitative determination of famotidine in human urine, maternal and umbilical cord plasma was developed and validated. The plasma samples were alkalized with ammonium hydroxide and extracted twice with ethyl acetate. The extraction recovery of famotidine in maternal and umbilical cord plasma ranged from 53% to 64% and 72% to 79%, respectively. Urine samples were directly diluted with the initial mobile phase then injected into the HPLC system. Chromatographic separation of famotidine was achieved by using a Phenomenex Synergi™ Hydro-RP™ column with a gradient elution of acetonitrile and 10 mM ammonium acetate aqueous solution (pH 8.3, adjusted with ammonium hydroxide). Mass Spectrometric detection of famotidine was set in the positive mode and used a selected ion monitoring method. Carbon-13-labeled famotidine was used as internal standard. The calibration curves were linear (r2> 0.99) in the concentration ranges of 0.631-252 ng/mL for umbilical and maternal plasma samples, and of 0.075-30.0 μg/mL for urine samples. The relative deviation of method was less than 14% for intra- and inter-day assays, and the accuracy ranged between 93% and 110%. The matrix effect of famotidine in human urine, maternal and umbilical cord plasma is less than 17%. PMID:23401067

  6. Umbilical hernia in cirrhotic patients: outcome of elective repair.

    PubMed

    Lasheen, Adel; Naser, Hatem M; Abohassan, Ahmed

    2013-12-01

    Cirrhotic patients with umbilical hernia have an increased likelihood of complications following repair. The aim of this study was to assess the outcomes of elective umbilical hernia repair in cirrhotic patients. Fifty patients having uncomplicated umbilical hernia with a cirrhotic liver were studied prospectively. These patients divided into three groups' according to Child-Turcotte-Pugh (CTP) classification. After management of coagulopathy, correction of hypoalbuminaemia and electrolytes imbalance, and control of ascites, all patients underwent elective hernia repair under regional anesthesia. A comparison was made between the three groups as regard the size of the defect in the linea Alba, operative time, postoperative morbidity and mortality, length of hospital stay, time of return to daily life and postoperative changes in liver function tests (LFTs) in relation to the regional anesthesia applied. hernioplasty was done under spinal anesthesia in 13 patients (26%), under epidural anesthesia in 10 patients (20%), under intercostal nerve block in 7 patients (14%), and under local anesthesia in 20 patients (40%). There was an increased safety (less changes in LFTs) in cases done under local anesthesia and intercostal nerve block. The overall complications rate was 30%. There was an increased complications rate towards the decompensated cases. The differences in the mean length of hospital stay and mean time of return to daily life are statistically significant between the three groups. Umbilical hernia recurrence rate was 2% and no mortality was reported in the study groups.

  7. Inductively coupled wireless RF coil arrays.

    PubMed

    Bulumulla, S B; Fiveland, E; Park, K J; Foo, T K; Hardy, C J

    2015-04-01

    As the number of coils increases in multi-channel MRI receiver-coil arrays, RF cables and connectors become increasingly bulky and heavy, degrading patient comfort and slowing workflow. Inductive coupling of signals provides an attractive "wireless" approach, with the potential to reduce coil weight and cost while simplifying patient setup. In this work, multi-channel inductively coupled anterior arrays were developed and characterized for 1.5T imaging. These comprised MR receiver coils inductively (or "wirelessly") linked to secondary or "sniffer" coils whose outputs were transmitted via preamps to the MR system cabinet. The induced currents in the imaging coils were blocked by passive diode circuits during RF transmit. The imaging arrays were totally passive, obviating the need to deliver power to the coils, and providing lightweight, untethered signal reception with easily positioned coils. Single-shot fast spin echo images were acquired from 5 volunteers using a 7-element inductively coupled coil array and a conventionally cabled 7-element coil array of identical geometry, with the inductively-coupled array showing a relative signal-to-noise ratio of 0.86 +/- 0.07. The concept was extended to a larger 9-element coil array to demonstrate the effect of coil element size on signal transfer and RF-transmit blocking. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Periprocedural safety of aneurysm embolization with the Medina Coil System: the early human experience.

    PubMed

    Turk, Aquilla S; Maia, Orlando; Ferreira, Christian Candido; Freitas, Diogo; Mocco, J; Hanel, Ricardo

    2016-02-01

    Intracranial saccular aneurysms, if untreated, carry a high risk of morbidity and mortality from intracranial bleeding. Embolization coils are the most common treatment. We describe the periprocedural safety and performance of the initial human experience with the next generation Medina Coil System. The Medina Coil System is a layered three-dimensional coil made from a radiopaque, shape set core wire, and shape memory alloy outer coil filaments. Nine aneurysms in five patients were selected for treatment with the Medina Coil System. Nine aneurysms in five patients, ranging from 5 to 17 mm in size in various locations, were treated with the Medina Coil System. No procedural or periprocedural complications were encountered. Procedure times, number of coils used to treat the aneurysm, and use of adjunctive devices were much less than anticipated if conventional coil technology had been used. The Medina Coil System is a next generation coil that combines all of the familiar and expected procedural safety and technique concepts associated with conventional coils. We found improved circumferential aneurysm filling, which may lead to improved long term outcomes, with fewer devices and faster operating times. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  9. Comparison of Pelvic Phased-Array versus Endorectal Coil Magnetic Resonance Imaging at 3 Tesla for Local Staging of Prostate Cancer

    PubMed Central

    Kim, Bum Soo; Kim, Tae-Hwan; Kwon, Tae Gyun

    2012-01-01

    Purpose Several studies have demonstrated the superiority of endorectal coil magnetic resonance imaging (MRI) over pelvic phased-array coil MRI at 1.5 Tesla for local staging of prostate cancer. However, few have studied which evaluation is more accurate at 3 Tesla MRI. In this study, we compared the accuracy of local staging of prostate cancer using pelvic phased-array coil or endorectal coil MRI at 3 Tesla. Materials and Methods Between January 2005 and May 2010, 151 patients underwent radical prostatectomy. All patients were evaluated with either pelvic phased-array coil or endorectal coil prostate MRI prior to surgery (63 endorectal coils and 88 pelvic phased-array coils). Tumor stage based on MRI was compared with pathologic stage. We calculated the specificity, sensitivity and accuracy of each group in the evaluation of extracapsular extension and seminal vesicle invasion. Results Both endorectal coil and pelvic phased-array coil MRI achieved high specificity, low sensitivity and moderate accuracy for the detection of extracapsular extension and seminal vesicle invasion. There were statistically no differences in specificity, sensitivity and accuracy between the two groups. Conclusion Overall staging accuracy, sensitivity and specificity were not significantly different between endorectal coil and pelvic phased-array coil MRI. PMID:22476999

  10. A study on geometry effect of transmission coil for micro size magnetic induction coil

    NASA Astrophysics Data System (ADS)

    Lee, Kyung Hwa; Jun, Byoung Ok; Kim, Seunguk; Lee, Gwang Jun; Ryu, Mingyu; Choi, Ji-Woong; Jang, Jae Eun

    2016-05-01

    The effects of transmission (Tx) coil structure have been studied for micro-size magnetic induction coil. The size of the receiving (Rx) coil should be shrunk to the micrometer level for the various new applications such as micro-robot and wireless body implanted devices. In case of the macro-scale magnetic induction coil, the power transmission efficiency is generally considered to be higher as the inductance of the transmission coil became larger; however, the large size difference between macro-size Tx coil and micro-size Rx coil can decrease the power transmission efficiency due to the difference of resonance frequency. Here, we study a correlation of the power transmission with the size and distance between the macro-size Tx and micro-size Rx coils using magnetic induction technique. The maximum power efficiency was 0.28/0.23/0.13/0.12% at the distance of 0.3/1/3/5 cm between Rx and Tx coil. In addition, more efficient wireless power transferring method is suggested with a floating coil for the body implantable devices. The voltage output increased up to 5.4 mV than the original one Tx coil system. The results demonstrated the foundational wireless power transferring system with enhanced power efficiency.

  11. Overview of torus magnet coil production at Fermilab for the Jefferson Lab 12-GeV Hall B upgrade

    DOE PAGES

    Krave, S.; Velev, G.; Makarov, A.; ...

    2016-02-29

    Fermi National Accelerator Laboratory (Fermilab) fabricated the torus magnet coils for the 12-GeV Hall B upgrade at Jefferson Lab (JLab). The production consisted of six large superconducting coils for the magnet and two spare coils. The toroidal field coils are approximately 2 m × 4 m × 5 cm thick. Each of these coils consists of two layers, each of which has 117 turns of copper-stabilized superconducting cable, which will be conduction cooled by supercritical helium. Due to the size of the coils and their unique geometry, Fermilab designed and fabricated specialized tooling and, together with JLab, developed unique manufacturingmore » techniques for each stage of the coil construction. Furthermore, this paper describes the tooling and manufacturing techniques required to produce the six production coils and the two spare coils needed by the project.« less

  12. Buried polar residues in coiled-coil interfaces.

    PubMed

    Akey, D L; Malashkevich, V N; Kim, P S

    2001-05-29

    Coiled coils, estimated to constitute 3-5% of the encoded residues in most genomes, are characterized by a heptad repeat, (abcdefg)(n), where the buried a and d positions form the interface between multiple alpha-helices. Although generally hydrophobic, a substantial fraction ( approximately 20%) of these a- and d-position residues are polar or charged. We constructed variants of the well-characterized coiled coil GCN4-p1 with a single polar residue (Asn, Gln, Ser, or Thr) at either an a or a d position. The stability and oligomeric specificity of each variant were measured, and crystal structures of coiled-coil trimers with threonine or serine at either an a or a d position were determined. The structures show how single polar residues in the interface affect not only local packing, but also overall coiled-coil geometry as seen by changes in the Crick supercoil parameters and core cavity volumes.

  13. Analysis and quantification of endovascular coil distribution inside saccular aneurysms using histological images.

    PubMed

    Morales, Hernán G; Larrabide, Ignacio; Geers, Arjan J; Dai, Daying; Kallmes, David F; Frangi, Alejandro F

    2013-11-01

    Endovascular coiling is often performed by first placing coils along the aneurysm wall to create a frame and then by filling up the aneurysm core. However, little attention has been paid to quantifying this filling strategy and to see how it changes for different packing densities. The purpose of this work is to analyze and quantify endovascular coil distribution inside aneurysms based on serial histological images of experimental aneurysms. Seventeen histological images from 10 elastase-induced saccular aneurysms in rabbits treated with coils were studied. In-slice coil density, defined as the area taken up by coil winds, was calculated on each histological image. Images were analyzed by partitioning the aneurysm along its longitudinal and radial axes. Coil distribution was quantified by measuring and comparing the in-slice coil density of each partition. Mean total in-slice coil density was 22.0 ± 6.2% (range 10.1-30.2%). The density was non-significantly different (p = 0.465) along the longitudinal axis. A significant difference (p < 0.001) between peripheral and core densities was found. Additionally, the peripheral-core density ratio was observed to be inversely proportional to the total in-slice coil density (R(2)=0.57, p <0.001). This ratio was near unity for high in-slice coil density (around 30%). These findings demonstrate and confirm that coils tend to be located near the aneurysm periphery when few are inserted. However, when more coils are added, the radial distribution becomes more homogeneous. Coils are homogeneously distributed along the longitudinal axis.

  14. Retreatment of Recurrent Internal Carotid-Posterior Communicating Artery Aneurysm after Coil Embolization

    PubMed Central

    TOYOTA, Shingo; TAKI, Takuyu; WAKAYAMA, Akatsuki; YOSHIMINE, Toshiki

    2015-01-01

    Internal carotid-posterior communicating artery (IC-PC) aneurysms account for more than 20% of all intracranial aneurysms. As a result of the increase in coiling, there has also been an increase in recurrent IC-PC aneurysms after coiling. We present our experience of 10 recurrent IC-PC aneurysms after coiling that were retreated using surgical or endovascular techniques in order to discuss the choice of treatment and the points of clipping without removal of coils. From 2007 to 2014, 10 recurrent IC-PC aneurysms after coiling were retreated. When the previous frames covered the aneurysms all around or almost around except a part of the neck, coiling was chosen. In other cases, clipping was chosen. Clipping was attempted without removal of coils when it was technically feasible. Among the 10 IC-PC aneurysms retreated, 3 were retreated with coiling and 7 were retreated with clipping. In all three cases retreated with coiling, almost complete occlusion was accomplished. In the seven cases retreated with clipping, coil extrusion was observed during surgery in six cases. In most of them, it was necessary to dissect strong adhesions around the coiled aneurysms and to utilize temporary occlusion of the internal carotid artery. In all seven cases, neck clipping was accomplished without the removal of coils. There were no neurological complications in any cases. The management of recurrent lesions of embolized IC-PC aneurysms requires appropriate choice of treatment using both coiling and clipping. Clipping, especially without the removal of coils, plays an important role in safe treatment. PMID:26437796

  15. Retreatment of Recurrent Internal Carotid-Posterior Communicating Artery Aneurysm after Coil Embolization.

    PubMed

    Toyota, Shingo; Taki, Takuyu; Wakayama, Akatsuki; Yoshimine, Toshiki

    2015-01-01

    Internal carotid-posterior communicating artery (IC-PC) aneurysms account for more than 20% of all intracranial aneurysms. As a result of the increase in coiling, there has also been an increase in recurrent IC-PC aneurysms after coiling. We present our experience of 10 recurrent IC-PC aneurysms after coiling that were retreated using surgical or endovascular techniques in order to discuss the choice of treatment and the points of clipping without removal of coils. From 2007 to 2014, 10 recurrent IC-PC aneurysms after coiling were retreated. When the previous frames covered the aneurysms all around or almost around except a part of the neck, coiling was chosen. In other cases, clipping was chosen. Clipping was attempted without removal of coils when it was technically feasible. Among the 10 IC-PC aneurysms retreated, 3 were retreated with coiling and 7 were retreated with clipping. In all three cases retreated with coiling, almost complete occlusion was accomplished. In the seven cases retreated with clipping, coil extrusion was observed during surgery in six cases. In most of them, it was necessary to dissect strong adhesions around the coiled aneurysms and to utilize temporary occlusion of the internal carotid artery. In all seven cases, neck clipping was accomplished without the removal of coils. There were no neurological complications in any cases. The management of recurrent lesions of embolized IC-PC aneurysms requires appropriate choice of treatment using both coiling and clipping. Clipping, especially without the removal of coils, plays an important role in safe treatment.

  16. Wireless power transmission for battery charging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mi, Chris; Li, Siqi; Nguyen, Trong-Duy

    A wireless power transmission system is provided for high power applications. The power transmission system is comprised generally of a charging unit configured to generate an alternating electromagnetic field and a receive unit configured to receive the alternating electromagnetic field from the charging unit. The charging unit includes a power source; an input rectifier; an inverter; and a transmit coil. The transmit coil has a spirangle arrangement segmented into n coil segments with capacitors interconnecting adjacent coil segments. The receive unit includes a receive coil and an output rectifier. The receive coil also has a spirangle arrangement segmented into mmore » coil segments with capacitors interconnecting adjacent coil segments.« less

  17. Fifty years of coiled-coils and alpha-helical bundles: a close relationship between sequence and structure.

    PubMed

    Parry, David A D; Fraser, R D Bruce; Squire, John M

    2008-09-01

    alpha-Helical coiled coils are remarkable for the diversity of related conformations that they adopt in both fibrous and globular proteins, and for the range of functions that they exhibit. The coiled coils are based on a heptad (7-residue), hendecad (11-residue) or a related quasi-repeat of apolar residues in the sequences of the alpha-helical regions involved. Most of these, however, display one or more sequence discontinuities known as stutters or stammers. The resulting coiled coils vary in length, in the number of chains participating, in the relative polarity of the contributing alpha-helical regions (parallel or antiparallel), and in the pitch length and handedness of the supercoil (left- or right-handed). Functionally, the concept that a coiled coil can act only as a static rod is no longer valid, and the range of roles that these structures have now been shown to exhibit has expanded rapidly in recent years. An important development has been the recognition that the delightful simplicity that exists between sequence and structure, and between structure and function, allows coiled coils with specialized features to be designed de novo.

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fabbricatore, P.; Ambrosio, G.; Cheban, S.

    The Mu2e Transport Solenoid consists of 52 coils arranged in 27 coil modules that form the S-shaped cold mass. Each coil is wound from Al-stabilized NbTi superconductor. The coils are supported by an external structural aluminum shell machined from a forged billet. Most of the coil modules house two coils, with the axis of each coil oriented at an angle of approximately 5° with respect to each other. The coils are indirectly cooled with LHe circulating in tubes welded on the shell. In order to enhance the cooling capacity, pure aluminum sheets connect the inner bore of the coils tomore » the cooling tubes. The coils are placed inside the shell by the means of a shrink-fit procedure. A full-size prototype, with all the features of the full assembly, was successfully manufactured in a collaboration between INFN Genova and Fermilab. In order to ensure an optimal mechanical prestress at the coil-shell interface, the coils are inserted into the shell through a shrink-fitting process. We present the details of the prototype with the design choices as validated by the structural analysis. In conclusion, the fabrication steps are described as well.« less

  19. Mu2e transport solenoid prototype design and manufacturing

    DOE PAGES

    Fabbricatore, P.; Ambrosio, G.; Cheban, S.; ...

    2016-02-08

    The Mu2e Transport Solenoid consists of 52 coils arranged in 27 coil modules that form the S-shaped cold mass. Each coil is wound from Al-stabilized NbTi superconductor. The coils are supported by an external structural aluminum shell machined from a forged billet. Most of the coil modules house two coils, with the axis of each coil oriented at an angle of approximately 5° with respect to each other. The coils are indirectly cooled with LHe circulating in tubes welded on the shell. In order to enhance the cooling capacity, pure aluminum sheets connect the inner bore of the coils tomore » the cooling tubes. The coils are placed inside the shell by the means of a shrink-fit procedure. A full-size prototype, with all the features of the full assembly, was successfully manufactured in a collaboration between INFN Genova and Fermilab. In order to ensure an optimal mechanical prestress at the coil-shell interface, the coils are inserted into the shell through a shrink-fitting process. We present the details of the prototype with the design choices as validated by the structural analysis. In conclusion, the fabrication steps are described as well.« less

  20. Performance of the Conduction-Cooled LDX Levitation Coil

    NASA Astrophysics Data System (ADS)

    Michael, P. C.; Schultz, J. H.; Smith, B. A.; Titus, P. H.; Radovinsky, A.; Zhukovsky, A.; Hwang, K. P.; Naumovich, G. J.; Camille, R. J.

    2004-06-01

    The Levitated Dipole Experiment (LDX) was developed to study plasma confinement in a dipole magnetic field. Plasma is confined in the magnetic field of a 680-kg Nb3Sn Floating Coil (F-coil) that is electromagnetically supported at the center of a 5-m diameter by 3-m tall vacuum chamber. The Levitation Coil (L-coil) is a 2800-turn, double pancake winding that supports the weight of the F-coil and controls its vertical position within the vacuum chamber. The use of high-temperature superconductor (HTS) Bi-2223 for the L-coil minimizes the electrical and cooling power needed for levitation. The L-coil winding pack and support plate are suspended within the L-coil cryostat and cooled by conduction to a single-stage cryocooler rated for 25-W heat load at approximately 20 K. The coil current leads consist of conduction-cooled copper running from room temperature to 80 K and a pair of commercially-available, 150-A HTS leads. An automatically filled liquid-nitrogen reservoir provides cooling for the coil's radiation shield and for the leads' 80-K heat stations. This paper discusses the L-coil system design and its observed cryogenic performance.

Top