Sample records for undergoing ct examinations

  1. Radiation assessment to paediatric with F-18-FDG undergo whole-body PET/CT examination

    NASA Astrophysics Data System (ADS)

    Dhalisa, H.; Mohamad, A. S.; Rafidah, Z.

    2016-01-01

    This study was carried out on wholebody radiation dose assessment to paediatrics patient who undergo PET/CT scanner at Institut Kanser Negara. Consist of 68 patients with varies of malignancies and epilepsy disease case covering age between 2 years to 12 years old. This is a retrospective study from 2010-2014. The use of PET/CT scanner as an advanced tool has been proven to give an extra radiation dose to the patient. It is because of the radiation exposure from the combination of both CT and PET scans rather than a single CT or PET scan. Furthermore, a study on radiation dose to paediatric patient undergoing PET/CT is rare in Malaysia. So, the aim of this study is to estimate the wholebody effective dose to paediatric patient in Malaysia. Effective dose from PET scan was calculated based on the activity of F18 FDG and dose coefficient reported in International Commission on Radiological Protection (ICRP) Publication 106. Effective dose from CT was determined using k coefficient as reported in ICRP publication 102 and Dose Length Product (DLP) value. The average effective dose from PET and CT were found to be 7.05mSv and 5.77mSv respectively. The mean wholebody effective dose received by a patient with combined PETCT examination was 12.78mSv. These results could be used as reference for dosimetry of a patient undergoing PETCT examination in Malaysia.

  2. Radiation assessment to paediatric with F-18-FDG undergo whole-body PET/CT examination

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dhalisa, H., E-mail: dhalisa82@gmail.com; Rafidah, Z.; Mohamad, A. S.

    2016-01-22

    This study was carried out on wholebody radiation dose assessment to paediatrics patient who undergo PET/CT scanner at Institut Kanser Negara. Consist of 68 patients with varies of malignancies and epilepsy disease case covering age between 2 years to 12 years old. This is a retrospective study from 2010-2014. The use of PET/CT scanner as an advanced tool has been proven to give an extra radiation dose to the patient. It is because of the radiation exposure from the combination of both CT and PET scans rather than a single CT or PET scan. Furthermore, a study on radiation dosemore » to paediatric patient undergoing PET/CT is rare in Malaysia. So, the aim of this study is to estimate the wholebody effective dose to paediatric patient in Malaysia. Effective dose from PET scan was calculated based on the activity of F18 FDG and dose coefficient reported in International Commission on Radiological Protection (ICRP) Publication 106. Effective dose from CT was determined using k coefficient as reported in ICRP publication 102 and Dose Length Product (DLP) value. The average effective dose from PET and CT were found to be 7.05mSv and 5.77mSv respectively. The mean wholebody effective dose received by a patient with combined PETCT examination was 12.78mSv. These results could be used as reference for dosimetry of a patient undergoing PETCT examination in Malaysia.« less

  3. Intramammary Findings on CT of the Chest – a Review of Normal Anatomy and Possible Findings

    PubMed Central

    Gossner, Johannes

    2016-01-01

    Summary Computed tomography (CT) is a frequently performed examination in women of all ages. In all thoracic CT examinations of the chest at least parts of the breasts are included. Therefore incidental breast pathology may be observed. It has been suggested that one out of 250 women undergoing chest CT will show a malignant incidental breast lesion. Given the high number of performed chest CT examinations, this contributes to a significant number of malignancies. In this review, after a brief discussion of the value of computed tomography in breast imaging, normal and pathologic findings are discussed to create awareness of this potential “black box” on chest CT. PMID:28058068

  4. Radiation dose exposure in patients affected by lymphoma undergoing repeat CT examinations: how to manage the radiation dose variability.

    PubMed

    Paolicchi, Fabio; Bastiani, Luca; Guido, Davide; Dore, Antonio; Aringhieri, Giacomo; Caramella, Davide

    2018-03-01

    To assess the variability of radiation dose exposure in patients affected by lymphoma undergoing repeat CT (computed tomography) examinations and to evaluate the influence of different scan parameters on the overall radiation dose. A series of 34 patients (12 men and 22 women with a median age of 34.4 years) with lymphoma, after the initial staging CT underwent repeat follow-up CT examinations. For each patient and each repeat examination, age, sex, use of AEC system (Automated Exposure Control, i.e. current modulation), scan length, kV value, number of acquired scans (i.e. number of phases), abdominal size diameter and dose length product (DLP) were recorded. The radiation dose of just one venous phase was singled out from the DLP of the entire examination. All scan data were retrieved by our PACS (Picture Archiving and Communication System) by means of a dose monitoring software. Among the variables we considered, no significant difference of radiation dose was observed among patients of different ages nor concerning tube voltage. On the contrary the dose delivered to the patients varied depending on sex, scan length and usage of AEC. No significant difference was observed depending on the behaviour of technologists, while radiologists' choices had indirectly an impact on the radiation dose due to the different number of scans requested by each of them. Our results demonstrate that patients affected by lymphoma who undergo repeat whole body CT scanning may receive unnecessary overexposure. We quantified and analyzed the most relevant variables in order to provide a useful tool to manage properly CT dose variability, estimating the amount of additional radiation dose for every single significant variable. Additional scans, incorrect scan length and incorrect usage of AEC system are the most relevant cause of patient radiation exposure.

  5. Organ doses for reference pediatric and adolescent patients undergoing computed tomography estimated by Monte Carlo simulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Choonsik; Kim, Kwang Pyo; Long, Daniel J.

    Purpose: To establish an organ dose database for pediatric and adolescent reference individuals undergoing computed tomography (CT) examinations by using Monte Carlo simulation. The data will permit rapid estimates of organ and effective doses for patients of different age, gender, examination type, and CT scanner model. Methods: The Monte Carlo simulation model of a Siemens Sensation 16 CT scanner previously published was employed as a base CT scanner model. A set of absorbed doses for 33 organs/tissues normalized to the product of 100 mAs and CTDI{sub vol} (mGy/100 mAs mGy) was established by coupling the CT scanner model with age-dependentmore » reference pediatric hybrid phantoms. A series of single axial scans from the top of head to the feet of the phantoms was performed at a slice thickness of 10 mm, and at tube potentials of 80, 100, and 120 kVp. Using the established CTDI{sub vol}- and 100 mAs-normalized dose matrix, organ doses for different pediatric phantoms undergoing head, chest, abdomen-pelvis, and chest-abdomen-pelvis (CAP) scans with the Siemens Sensation 16 scanner were estimated and analyzed. The results were then compared with the values obtained from three independent published methods: CT-Expo software, organ dose for abdominal CT scan derived empirically from patient abdominal circumference, and effective dose per dose-length product (DLP). Results: Organ and effective doses were calculated and normalized to 100 mAs and CTDI{sub vol} for different CT examinations. At the same technical setting, dose to the organs, which were entirely included in the CT beam coverage, were higher by from 40 to 80% for newborn phantoms compared to those of 15-year phantoms. An increase of tube potential from 80 to 120 kVp resulted in 2.5-2.9-fold greater brain dose for head scans. The results from this study were compared with three different published studies and/or techniques. First, organ doses were compared to those given by CT-Expo which revealed dose differences up to several-fold when organs were partially included in the scan coverage. Second, selected organ doses from our calculations agreed to within 20% of values derived from empirical formulae based upon measured patient abdominal circumference. Third, the existing DLP-to-effective dose conversion coefficients tended to be smaller than values given in the present study for all examinations except head scans. Conclusions: A comprehensive organ/effective dose database was established to readily calculate doses for given patients undergoing different CT examinations. The comparisons of our results with the existing studies highlight that use of hybrid phantoms with realistic anatomy is important to improve the accuracy of CT organ dosimetry. The comprehensive pediatric dose data developed here are the first organ-specific pediatric CT scan database based on the realistic pediatric hybrid phantoms which are compliant with the reference data from the International Commission on Radiological Protection (ICRP). The organ dose database is being coupled with an adult organ dose database recently published as part of the development of a user-friendly computer program enabling rapid estimates of organ and effective dose doses for patients of any age, gender, examination types, and CT scanner model.« less

  6. Projected Effects of Radiation-Induced Cancers on Life Expectancy in Patients Undergoing CT Surveillance for Limited-Stage Hodgkin Lymphoma: A Markov Model.

    PubMed

    Lowry, Kathryn P; Turan, Ekin A; Eisenberg, Jonathan; Kong, Chung Y; Barnes, Jeffrey A; Pandharipande, Pari Vijay

    2015-06-01

    Patients with limited-stage Hodgkin lymphoma (HL) undergo frequent posttreatment surveillance CT examinations, raising concerns about the cumulative magnitude of radiation exposure. The purpose of this study was to project radiation-induced cancer risks relative to competing risks of HL and account for the differential timing of each. We adapted a previously developed Markov model to project lifetime mortality risks and life expectancy losses due to HL versus radiation-induced cancers in HL patients undergoing surveillance CT. In the base case, we modeled 35-year-old men and women undergoing seven CT examinations of the chest, abdomen, and pelvis over 5 years. Radiation-induced cancer risks and deaths for 17 organ systems were modeled using an organ-specific approach, accounting for specific anatomy exposed at CT. Cohorts of 20-, 50-, and 65-year-old men and women were evaluated in secondary analyses. Markov chain Monte Carlo methods were used to estimate the uncertainty of radiation risk projections. For 35-year-old adults, we projected 3324/100,000 (men) and 3345/100,000 (women) deaths from recurrent lymphoma and 245/100,000 (men, 95% uncertainty interval [UI]: 121-369) and 317/100,000 (women, 95% UI: 202-432) radiation-induced cancer deaths. Discrepancies in life expectancy losses between HL (428 days in men, 482 days in women) and radiation-induced cancers (11.6 days in men, [95% UI: 5.7-17.5], 15.6 days in women [95% UI: 9.8-21.4]) were proportionately greater because of the delayed timing of radiation-induced cancers relative to recurrent HL. Deaths and life expectancy losses from radiation-induced cancers were highest in the youngest cohorts. Given the low rate of radiation-induced cancer deaths associated with CT surveillance, modest CT benefits would justify its use in patients with limited-stage HL.

  7. Calculation of Organ Doses for a Large Number of Patients Undergoing CT Examinations.

    PubMed

    Bahadori, Amir; Miglioretti, Diana; Kruger, Randell; Flynn, Michael; Weinmann, Sheila; Smith-Bindman, Rebecca; Lee, Choonsik

    2015-10-01

    The objective of our study was to develop an automated calculation method to provide organ dose assessment for a large cohort of pediatric and adult patients undergoing CT examinations. We adopted two dose libraries that were previously published: the volume CT dose index-normalized organ dose library and the tube current-exposure time product (100 mAs)-normalized weighted CT dose index library. We developed an algorithm to calculate organ doses using the two dose libraries and the CT parameters available from DICOM data. We calculated organ doses for pediatric (n = 2499) and adult (n = 2043) CT examinations randomly selected from four health care systems in the United States and compared the adult organ doses with the values calculated from the ImPACT calculator. The median brain dose was 20 mGy (pediatric) and 24 mGy (adult), and the brain dose was greater than 40 mGy for 11% (pediatric) and 18% (adult) of the head CT studies. Both the National Cancer Institute (NCI) and ImPACT methods provided similar organ doses (median discrepancy < 20%) for all organs except the organs located close to the scanning boundaries. The visual comparisons of scanning coverage and phantom anatomies revealed that the NCI method, which is based on realistic computational phantoms, provides more accurate organ doses than the ImPACT method. The automated organ dose calculation method developed in this study reduces the time needed to calculate doses for a large number of patients. We have successfully used this method for a variety of CT-related studies including retrospective epidemiologic studies and CT dose trend analysis studies.

  8. Estimation of the total effective dose from low-dose CT scans and radiopharmaceutical administrations delivered to patients undergoing SPECT/CT explorations.

    PubMed

    Montes, Carlos; Tamayo, Pilar; Hernandez, Jorge; Gomez-Caminero, Felipe; García, Sofia; Martín, Carlos; Rosero, Angela

    2013-08-01

    Hybrid imaging, such as SPECT/CT, is used in routine clinical practice, allowing coregistered images of the functional and structural information provided by the two imaging modalities. However, this multimodality imaging may mean that patients are exposed to a higher radiation dose than those receiving SPECT alone. The study aimed to determine the radiation exposure of patients who had undergone SPECT/CT examinations and to relate this to the Background Equivalent Radiation Time (BERT). 145 SPECT/CT studies were used to estimate the total effective dose to patients due to both radiopharmaceutical administrations and low-dose CT scans. The CT contribution was estimated by the Dose-Length Product method. Specific conversion coefficients were calculated for SPECT explorations. The radiation dose from low-dose CTs ranged between 0.6 mSv for head and neck CT and 2.6 mSv for whole body CT scan, representing a maximum of 1 year of background radiation exposure. These values represent a decrease of 80-85% with respect to the radiation dose from diagnostic CT. The radiation exposure from radiopharmaceutical administration varied from 2.1 mSv for stress myocardial perfusion SPECT to 26 mSv for gallium SPECT in patients with lymphoma. The BERT ranged from 1 to 11 years. The contribution of low-dose CT scans to the total radiation dose to patients undergoing SPECT/CT examinations is relatively low compared with the effective dose from radiopharmaceutical administration. When a CT scan is only acquired for anatomical localization and attenuation correction, low-dose CT scan is justified on the basis of its lower dose.

  9. Factors affecting the incidence of contrast-induced nephropathy in patients undergoing computed tomography.

    PubMed

    Heras Benito, M; Garrido Blázquez, M; Gómez Sanz, Y; Bernardez Mardomingo, M; Ruiz Cacho, J; Rodríguez Recio, F J; Fernández-Reyes Luis, M J

    2018-05-17

    To analyze the incidence of contrast-induced nephropathy in a cohort of patients undergoing computed tomography (CT) with intravenous iodinated contrast material. To evaluate the efficacy of N-acetylcysteine in preventing contrast-induced nephropathy. This prospective observational study was carried out in the months comprising March 2016 through July 2016. We selected the first five patients scheduled to undergo CT examination each day who agreed to participate and signed the informed consent form. We recorded patients' cardiovascular histories, chronic treatments, and indications for the CT examination. We measured blood levels of creatinine and urea before and after the CT examination. We used the Modification of Diet in Renal Disease (MDRD-4) equation to estimate the glomerular filtration rate. We analyzed the type and dose of contrast material. We recorded whether N-acetylcysteine was administered before the CT examination. We used SPSS 15.0 ® to compare means and proportions. Statistical significance was set at p < 0.05. No incidents of contrast-induced nephropathy were detected in any of the 202 patients included [mean age, 63.92 ± 12 years (range 22-87); 57.4% male; 21.8% diabetic; 39.6% hypertensive; 87.1% had MDRD4 ≥ 60 ml/min/1.73 m 2 (89.45 ± 14, range 62.36-134.14) and 12.9% had MDRD4 < 60 ml/min/1.73 m 2 (45.38 ± 11, range 9.16-58.90)]. The most common indication for CT examinations was oncologic (81.2%). The only contrast agent administered was iopamidol; the mean dose was 107.83 ± 11 ml (range 70-140). The mean interval between pre-CT and post-CT laboratory tests was 4.06 ± 1 days. Only 13 patients received N-acetylcysteine; 9 of these had MDRD < 60 ml/min/1.73 m 2 and 4 had MDRD4 ≥ 60 ml/min/1.73 m 2 (p = 0.000). The incidence of contrast-induced nephropathy was not significant in patients with glomerular filtration rates greater than 30 ml/min/1.73 m 2 : these favorable results might be due to analyzing only scheduled examinations and to using relatively low doses of a "nonionic" iodinated contrast agent. Copyright © 2018 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  10. Low-dose computed tomography scans with automatic exposure control for patients of different ages undergoing cardiac PET/CT and SPECT/CT.

    PubMed

    Yang, Ching-Ching; Yang, Bang-Hung; Tu, Chun-Yuan; Wu, Tung-Hsin; Liu, Shu-Hsin

    2017-06-01

    This study aimed to evaluate the efficacy of automatic exposure control (AEC) in order to optimize low-dose computed tomography (CT) protocols for patients of different ages undergoing cardiac PET/CT and single-photon emission computed tomography/computed tomography (SPECT/CT). One PET/CT and one SPECT/CT were used to acquire CT images for four anthropomorphic phantoms representative of 1-year-old, 5-year-old and 10-year-old children and an adult. For the hybrid systems investigated in this study, the radiation dose and image quality of cardiac CT scans performed with AEC activated depend mainly on the selection of a predefined image quality index. Multiple linear regression methods were used to analyse image data from anthropomorphic phantom studies to investigate the effects of body size and predefined image quality index on CT radiation dose in cardiac PET/CT and SPECT/CT scans. The regression relationships have a coefficient of determination larger than 0.9, indicating a good fit to the data. According to the regression models, low-dose protocols using the AEC technique were optimized for patients of different ages. In comparison with the standard protocol with AEC activated for adult cardiac examinations used in our clinical routine practice, the optimized paediatric protocols in PET/CT allow 32.2, 63.7 and 79.2% CT dose reductions for anthropomorphic phantoms simulating 10-year-old, 5-year-old and 1-year-old children, respectively. The corresponding results for cardiac SPECT/CT are 8.4, 51.5 and 72.7%. AEC is a practical way to reduce CT radiation dose in cardiac PET/CT and SPECT/CT, but the AEC settings should be determined properly for optimal effect. Our results show that AEC does not eliminate the need for paediatric protocols and CT examinations using the AEC technique should be optimized for paediatric patients to reduce the radiation dose as low as reasonably achievable.

  11. Multislice CT of the head and body routine scans: Are scanning protocols adjusted for paediatric patients?

    PubMed Central

    Sun, Z; Al Ghamdi, KS; Baroum, IH

    2012-01-01

    Purpose: To investigate whether the multislice CT scanning protocols of head, chest and abdomen are adjusted according to patient’s age in paediatric patients. Materials and Methods: Multislice CT examination records of paediatric patients undergoing head, chest and abdomen scans from three public hospitals during a one-year period were retrospectively reviewed. Patients were categorised into the following age groups: under 4 years, 5–8 years, 9–12 years and 13–16 years, while the tube current was classified into the following ranges: < 49 mA, 50–99 mA, 100–149 mA, 150–199 mA, > 200 mA and unknown. Results: A total of 4998 patient records, comprising a combination of head, chest and abdomen CT scans, were assessed, with head CT scans representing nearly half of the total scans. Age-based adjusted CT protocols were observed in most of the scans with higher tube current setting being used with increasing age. However, a high tube current (150–199 mA) was still used in younger patients (0–8 years) undergoing head CT scans. In one hospital, CT protocols remained constant across all age groups, indicating potential overexposure to the patients. Conclusion: This analysis shows that paediatric CT scans are adjusted according to the patient’s age in most of the routine CT examinations. This indicates increased awareness regarding radiation risks associated with CT. However, high tube current settings are still used in younger patient groups, thus, optimisation of paediatric CT protocols and implementation of current guidelines, such as age-and weight-based scanning, should be recommended in daily practice. PMID:22970059

  12. SimDoseCT: dose reporting software based on Monte Carlo simulation for a 320 detector-row cone-beam CT scanner and ICRP computational adult phantoms

    NASA Astrophysics Data System (ADS)

    Cros, Maria; Joemai, Raoul M. S.; Geleijns, Jacob; Molina, Diego; Salvadó, Marçal

    2017-08-01

    This study aims to develop and test software for assessing and reporting doses for standard patients undergoing computed tomography (CT) examinations in a 320 detector-row cone-beam scanner. The software, called SimDoseCT, is based on the Monte Carlo (MC) simulation code, which was developed to calculate organ doses and effective doses in ICRP anthropomorphic adult reference computational phantoms for acquisitions with the Aquilion ONE CT scanner (Toshiba). MC simulation was validated by comparing CTDI measurements within standard CT dose phantoms with results from simulation under the same conditions. SimDoseCT consists of a graphical user interface connected to a MySQL database, which contains the look-up-tables that were generated with MC simulations for volumetric acquisitions at different scan positions along the phantom using any tube voltage, bow tie filter, focal spot and nine different beam widths. Two different methods were developed to estimate organ doses and effective doses from acquisitions using other available beam widths in the scanner. A correction factor was used to estimate doses in helical acquisitions. Hence, the user can select any available protocol in the Aquilion ONE scanner for a standard adult male or female and obtain the dose results through the software interface. Agreement within 9% between CTDI measurements and simulations allowed the validation of the MC program. Additionally, the algorithm for dose reporting in SimDoseCT was validated by comparing dose results from this tool with those obtained from MC simulations for three volumetric acquisitions (head, thorax and abdomen). The comparison was repeated using eight different collimations and also for another collimation in a helical abdomen examination. The results showed differences of 0.1 mSv or less for absolute dose in most organs and also in the effective dose calculation. The software provides a suitable tool for dose assessment in standard adult patients undergoing CT examinations in a 320 detector-row cone-beam scanner.

  13. SimDoseCT: dose reporting software based on Monte Carlo simulation for a 320 detector-row cone-beam CT scanner and ICRP computational adult phantoms.

    PubMed

    Cros, Maria; Joemai, Raoul M S; Geleijns, Jacob; Molina, Diego; Salvadó, Marçal

    2017-07-17

    This study aims to develop and test software for assessing and reporting doses for standard patients undergoing computed tomography (CT) examinations in a 320 detector-row cone-beam scanner. The software, called SimDoseCT, is based on the Monte Carlo (MC) simulation code, which was developed to calculate organ doses and effective doses in ICRP anthropomorphic adult reference computational phantoms for acquisitions with the Aquilion ONE CT scanner (Toshiba). MC simulation was validated by comparing CTDI measurements within standard CT dose phantoms with results from simulation under the same conditions. SimDoseCT consists of a graphical user interface connected to a MySQL database, which contains the look-up-tables that were generated with MC simulations for volumetric acquisitions at different scan positions along the phantom using any tube voltage, bow tie filter, focal spot and nine different beam widths. Two different methods were developed to estimate organ doses and effective doses from acquisitions using other available beam widths in the scanner. A correction factor was used to estimate doses in helical acquisitions. Hence, the user can select any available protocol in the Aquilion ONE scanner for a standard adult male or female and obtain the dose results through the software interface. Agreement within 9% between CTDI measurements and simulations allowed the validation of the MC program. Additionally, the algorithm for dose reporting in SimDoseCT was validated by comparing dose results from this tool with those obtained from MC simulations for three volumetric acquisitions (head, thorax and abdomen). The comparison was repeated using eight different collimations and also for another collimation in a helical abdomen examination. The results showed differences of 0.1 mSv or less for absolute dose in most organs and also in the effective dose calculation. The software provides a suitable tool for dose assessment in standard adult patients undergoing CT examinations in a 320 detector-row cone-beam scanner.

  14. Children with chronic renal disease undergoing dialysis or conservative treatment--differences in structural and functional echocardiographic parameters.

    PubMed

    Scavarda, Valeska Tavares; Pinheiro, Aurelio Carvalho; Costa, Symône Damasceno; de Andrade, Zélia Maria; Carvalhaes, João Tomás de Abreu; Campos, Orlando; Carvalho, Antonio Carlos; Moises, Valdir Ambrosio

    2014-10-01

    Cardiac disease frequently occurs in children with chronic kidney disease (CKD) undergoing dialysis (DI), but it is not well studied in patients undergoing conservative treatment (CT). The aim of our study was to use echocardiography to analyze and compare the cardiac involvement of children with CKD undergoing DI or CT. Seventy-one children with CKD were included; 41 undergoing DI and 30 undergoing CT. There were 33 controls. Measurements of arterial pressure and structural and functional echocardiographic variables were obtained; the children were followed up for 18 months. Tests of comparison and multiple regression were used; significant if P < 0.05. Arterial hypertension (AH) was present in 37 of 71 (52%) children with CKD: 27 (65.8%) in DI and 10 (33.3%) in CT (X2 = 8.7; P = 0.003). An abnormal left ventricular geometric pattern was present in 37/41 (90.3%) undergoing DI, 33 had left ventricular hypertrophy (LVH), and in 14/30 (46.7%) undergoing CT, 5 had LVH. Ejection fraction was normal in all groups; diastolic function alteration (DFA) occurred in 28/41 (68.3%) children on DI and in 10/30 (33.3%) on CT (X2 = 9.2; P = 0.002). For children with CKD, DI (P = 0.002) and hypertension (P = 0.04) were associated with LVH; among those on DI, only AH was associated with LVH (P = 0.02). During the follow-up, 18 (43.9%) children undergoing DI had at least one cardiovascular event. Children with CKD undergoing CT had less cardiac involvement than those undergoing DI. LVH was associated with DI and AH in all children with CKD and with AH in those on DI.

  15. Evaluation of diagnostic value of CT scan, physical examination and ultrasound based on pathological findings in patients with pelvic masses.

    PubMed

    Firoozabadi, Razieh Dehghani; Karimi Zarchi, Mojgan; Mansurian, Hamid Reza; Moghadam, Bita Rafiei; Teimoori, Soraya; Naseri, Ali

    2011-01-01

    Because benign and malignant cervical and ovarian masses occur with different percentages in different age groups, the importance of primary diagnosis and selection of a suitable surgical procedure is underlined. Diagnosis of pelvic masses is carried out using ultrasound, physical examination, CT scan and MRI. The objective of this study is to evaluate the diagnostic value of CT scan in pelvic masses in comparison with physical examination-ultrasound based on pathology of the lesion in patients undergoing laparotomic surgery. This analytic-descriptive study focused on age, sonographic findings, physical examinations, CT scan and pathological findings in 139 patients with pelvic mass, gathered with questionnaires and statistically analayzed using the SPSS software programme. Of 139 patients with pelvic mass (patients aged from 17 to 75 years old), 62 (44%) cases were diagnosed as benign and 77 (55.4%) as malignant; among them malignant tratoma serocyst adenocarsinoma with 33 (23.7%) cases and benign myoma with 21 (15.2%) cases comprised the most frequent cases. The sensitivity and specificity of sonography-physical examination were 51.9% and 87.9% respectively and the sensitivity and specificity of CT scan images were 79.2% and 91.6% respectively. It was shown that CT scan images were more consistant with pathological findings in predicting appropriate surgical procedures than do sonography-physical examinations. The sensitivity of CT scan is far higher than that of sonography-physical examination in the diagnosis of pelvic mass malignancy.

  16. It's a question of endurance - Patients with head and neck cancer experiences of 18F-FDG PET/CT in a fixation mask.

    PubMed

    Andersson, Camilla; Röing, Marta; Tiblom Ehrsson, Ylva; Johansson, Birgitta

    2017-08-01

    This study aimed to explore how patients with head and neck cancer experienced undergoing an 18 F-fluoro-deoxy-glucose positrons emissions tomography/computed tomography ( 18 F-FDG PET/CT) examination in a fixation mask. Interviews were conducted with nine patients with known or suspected head and neck cancer who were scheduled for the examination for the first time. The phenomenological method according to van Manen and his four lifeworld existentials; lived space, lived body, lived time, and lived relation was used to analyse the interviews. The thoughts and feelings of the patients during the PET/CT examination varied, some found it very difficult, while others did not. However, for all the patients, it was an experience that required some form of coping to maintain composure for example distraction. PET/CT examnation in a fixation mask may be strenuous for some patients. Patients need more detailed information, including suggestions for coping behaviours, prior to the examination, as well as higher level of support during and after the examination. The results of this study may be used to improve patient care and optimize the procedure of PET/CT examination in a fixation mask. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Assessment of Safety and Interference Issues of Radio Frequency Identification Devices in 0.3 Tesla Magnetic Resonance Imaging and Computed Tomography

    PubMed Central

    Periyasamy, M.; Dhanasekaran, R.

    2014-01-01

    The objective of this study was to evaluate two issues regarding magnetic resonance imaging (MRI) including device functionality and image artifacts for the presence of radio frequency identification devices (RFID) in association with 0.3 Tesla at 12.7 MHz MRI and computed tomography (CT) scanning. Fifteen samples of RFID tags with two different sizes (wristband and ID card types) were tested. The tags were exposed to several MR-imaging conditions during MRI examination and X-rays of CT scan. Throughout the test, the tags were oriented in three different directions (axial, coronal, and sagittal) relative to MRI system in order to cover all possible situations with respect to the patient undergoing MRI and CT scanning, wearing a RFID tag on wrist. We observed that the tags did not sustain physical damage with their functionality remaining unaffected even after MRI and CT scanning, and there was no alternation in previously stored data as well. In addition, no evidence of either signal loss or artifact was seen in the acquired MR and CT images. Therefore, we can conclude that the use of this passive RFID tag is safe for a patient undergoing MRI at 0.3 T/12.7 MHz and CT Scanning. PMID:24701187

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Ching-Ching, E-mail: cyang@tccn.edu.tw; Liu, Shu-Hsin; Mok, Greta S. P.

    Purpose: This study aimed to tailor the CT imaging protocols for pediatric patients undergoing whole-body PET/CT examinations with appropriate attention to radiation exposure while maintaining adequate image quality for anatomic delineation of PET findings and attenuation correction of PET emission data. Methods: The measurements were made by using three anthropomorphic phantoms representative of 1-, 5-, and 10-year-old children with tube voltages of 80, 100, and 120 kVp, tube currents of 10, 40, 80, and 120 mA, and exposure time of 0.5 s at 1.75:1 pitch. Radiation dose estimates were derived from the dose-length product and were used to calculate riskmore » estimates for radiation-induced cancer. The influence of image noise on image contrast and attenuation map for CT scans were evaluated based on Pearson's correlation coefficient and covariance, respectively. Multiple linear regression methods were used to investigate the effects of patient age, tube voltage, and tube current on radiation-induced cancer risk and image noise for CT scans. Results: The effective dose obtained using three anthropomorphic phantoms and 12 combinations of kVp and mA ranged from 0.09 to 4.08 mSv. Based on our results, CT scans acquired with 80 kVp/60 mA, 80 kVp/80 mA, and 100 kVp/60 mA could be performed on 1-, 5-, and 10-year-old children, respectively, to minimize cancer risk due to CT scans while maintaining the accuracy of attenuation map and CT image contrast. The effective doses of the proposed protocols for 1-, 5- and 10-year-old children were 0.65, 0.86, and 1.065 mSv, respectively. Conclusions: Low-dose pediatric CT protocols were proposed to balance the tradeoff between radiation-induced cancer risk and image quality for patients ranging in age from 1 to 10 years old undergoing whole-body PET/CT examinations.« less

  19. Hypertensive crisis due to contrast-enhanced computed tomography in a patient with malignant pheochromocytoma.

    PubMed

    Nakano, Sachiko; Tsushima, Yoshito; Taketomi-Takahashi, Ayako; Higuchi, Tetsuya; Amanuma, Makoto; Oriuchi, Noboru; Endo, Keigo

    2011-07-01

    A 63-year-old man underwent computed tomography (CT) using intravenous low-osmolar iodine contrast medium (LOCM) 6 days after undergoing high-dose (131)I-MIBG therapy for metastatic pheochromocytoma. Immediately after the CT examination, his blood pressure increased to 260/160 mmHg (from 179/101 mmHg before the examination). Phentolamine mesilate was administered, and the blood pressure rapidly went back to normal. Although hypertensive crisis after administration of LOCM is rare, this case suggests that high-dose (131)IMIBG therapy may be a risk factor for hypertensive crisis after administration of intravenous LOCM.

  20. Randomized controlled trial of relaxation music to reduce heart rate in patients undergoing cardiac CT.

    PubMed

    Ng, Ming Yen; Karimzad, Yasser; Menezes, Ravi J; Wintersperger, Bernd J; Li, Qin; Forero, Julian; Paul, Narinder S; Nguyen, Elsie T

    2016-10-01

    To evaluate the heart rate lowering effect of relaxation music in patients undergoing coronary CT angiography (CCTA), pulmonary vein CT (PVCT) and coronary calcium score CT (CCS). Patients were randomised to a control group (i.e. standard of care protocol) or to a relaxation music group (ie. standard of care protocol with music). The groups were compared for heart rate, radiation dose, image quality and dose of IV metoprolol. Both groups completed State-Trait Anxiety Inventory anxiety questionnaires to assess patient experience. One hundred and ninety-seven patients were recruited (61.9 % males); mean age 56y (19-86 y); 127 CCTA, 17 PVCT, 53 CCS. No significant difference in heart rate, radiation dose, image quality, metoprolol dose and anxiety scores. 86 % of patients enjoyed the music. 90 % of patients in the music group expressed a strong preference to have music for future examinations. The patient cohort demonstrated low anxiety levels prior to CT. Relaxation music in CCTA, PVCT and CCS does not reduce heart rate or IV metoprolol use. Patients showed low levels of anxiety indicating that anxiolytics may not have a significant role in lowering heart rate. Music can be used in cardiac CT to improve patient experience. • Relaxation music does not reduce heart rate in cardiac CT • Relaxation music does not reduce beta-blocker use in cardiac CT • Relaxation music has no effect on cardiac CT image quality • Low levels of anxiety are present in patients prior to cardiac CT • Patients enjoyed the relaxation music and this results in improved patient experience.

  1. Effective doses to patients undergoing thoracic computed tomography examinations.

    PubMed

    Huda, W; Scalzetti, E M; Roskopf, M

    2000-05-01

    The purpose of this study was to investigate how x-ray technique factors and effective doses vary with patient size in chest CT examinations. Technique factors (kVp, mAs, section thickness, and number of sections) were recorded for 44 patients who underwent a routine chest CT examination. Patient weights were recorded together with dimensions and mean Hounsfield unit values obtained from representative axial CT images. The total mass of directly irradiated patient was modeled as a cylinder of water to permit the computation of the mean patient dose and total energy imparted for each chest CT examination. Computed values of energy imparted during the chest CT examination were converted into effective doses taking into account the patient weight. Patient weights ranged from 4.5 to 127 kg, and half the patients in this study were children under 18 years of age. All scans were performed at 120 kVp with a 1 s scan time. The selected tube current showed no correlation with patient weight (r2=0.06), indicating that chest CT examination protocols do not take into account for the size of the patient. Energy imparted increased with increasing patient weight, with values of energy imparted for 10 and 70 kg patients being 85 and 310 mJ, respectively. The effective dose showed an inverse correlation with increasing patient weight, however, with values of effective dose for 10 and 70 kg patients being 9.6 and 5.4 mSv, respectively. Current CT technique factors (kVp/mAs) used to perform chest CT examinations result in relatively high patient doses, which could be reduced by adjusting technique factors based on patient size.

  2. First installation of a dual-room IVR-CT system in the emergency room.

    PubMed

    Wada, Daiki; Nakamori, Yasushi; Kanayama, Shuji; Maruyama, Shuhei; Kawada, Masahiro; Iwamura, Hiromu; Hayakawa, Koichi; Saito, Fukuki; Kuwagata, Yasuyuki

    2018-03-05

    Computed tomography (CT) embedded in the emergency room has gained importance in the early diagnostic phase of trauma care. In 2011, we implemented a new trauma workflow concept with a sliding CT scanner system with interventional radiology features (IVR-CT) that allows CT examination and emergency therapeutic intervention without relocating the patient, which we call the Hybrid emergency room (Hybrid ER). In the Hybrid ER, all life-saving procedures, CT examination, damage control surgery, and transcatheter arterial embolisation can be performed on the same table. Although the trauma workflow realized in the Hybrid ER may improve mortality in severe trauma, the Hybrid ER can potentially affect the efficacy of other in/outpatient diagnostic workflow because one room is occupied by one severely injured patient undergoing both emergency trauma care and CT scanning for long periods. In July 2017, we implemented a new trauma workflow concept with a dual-room sliding CT scanner system with interventional radiology features (dual-room IVR-CT) to increase patient throughput. When we perform emergency surgery or interventional radiology for a severely injured or ill patient in the Hybrid ER, the sliding CT scanner moves to the adjacent CT suite, and we can perform CT scanning of another in/outpatient. We believe that dual-room IVR-CT can contribute to the improvement of both the survival of severely injured or ill patients and patient throughput.

  3. Pediatric Emergency CT Scans at a Children's Hospital and at Community Hospitals: Radiation Technical Factors Are an Important Source of Radiation Exposure.

    PubMed

    Agarwal, Saurabh; Jokerst, Clinton; Siegel, Marilyn J; Hildebolt, Charles

    2015-08-01

    This article compares the technical factors-in particular, tube current and voltage-and the resultant exposure to radiation associated with CT examinations performed at a children's hospital and at more general community hospital emergency departments (EDs). CT scans obtained at community hospital EDs were retrospectively reviewed and compared with CT scans obtained at a children's hospital, to assess differences in kilovoltage, tube current, and volume CT dose index (CTDIvol) used. The number of scans obtained during the contrast-enhanced phase was also assessed. Parametric and nonparametric statistical analyses were used to test differences. A total of 233 body CT examinations were performed at community hospitals, and 287 were performed at a children's hospital. At both types of hospital, the median patient age was 12 years (p = 0.66). Of the body CT scans obtained at community hospitals that focused on the care of adult patients, 194 of 233 (83%) used a tube voltage of 120 kVp, 29 of 233 (12%) used 100 kVp, and two of 233 (< 1%) used 80 kVp. Of the body CT scans obtained at the children's hospital, 121 of 287 (42%) used a tube voltage of 120 kVp, 129 of 287 (45%) used 100 kVp, and 36 of 287 (13%) used 80 kVp. The median tube current was also lower at the children's hospital (110 vs 125 mA) (p < 0.001). At the community hospitals, 11 of 233 studies were multiphasic, whereas at the children's hospital, there were no multiphasic studies. For all CT types, the median CTDIvol was 4.9 mGy (range, 2.5-8.2 mGy) at the children's hospital and 8.6 mGy (range, 6.0-14.4 mGy) at the community hospitals (p < 0.001). The results of this study suggest that a large proportion of children who undergo CT at community hospitals receive relatively higher radiation doses than children who undergo CT at children's hospitals. This finding is related to the higher tube settings (in particular, kilovoltage) used at community hospitals.

  4. WAZA-ARI: computational dosimetry system for X-ray CT examinations II: development of web-based system.

    PubMed

    Ban, Nobuhiko; Takahashi, Fumiaki; Ono, Koji; Hasegawa, Takayuki; Yoshitake, Takayasu; Katsunuma, Yasushi; Sato, Kaoru; Endo, Akira; Kai, Michiaki

    2011-07-01

    A web-based dose computation system, WAZA-ARI, is being developed for patients undergoing X-ray CT examinations. The system is implemented in Java on a Linux server running Apache Tomcat. Users choose scanning options and input parameters via a web browser over the Internet. Dose coefficients, which were calculated in a Japanese adult male phantom (JM phantom) are called upon user request and are summed over the scan range specified by the user to estimate a normalised dose. Tissue doses are finally computed based on the radiographic exposure (mA s) and the pitch factor. While dose coefficients are currently available only for limited CT scanner models, the system has achieved a high degree of flexibility and scalability without the use of commercial software.

  5. Estimating radiation dose to organs of patients undergoing conventional and novel multidetector CT exams using Monte Carlo simulations

    NASA Astrophysics Data System (ADS)

    Angel, Erin

    Advances in Computed Tomography (CT) technology have led to an increase in the modality's diagnostic capabilities and therefore its utilization, which has in turn led to an increase in radiation exposure to the patient population. As a result, CT imaging currently constitutes approximately half of the collective exposure to ionizing radiation from medical procedures. In order to understand the radiation risk, it is necessary to estimate the radiation doses absorbed by patients undergoing CT imaging. The most widely accepted risk models are based on radiosensitive organ dose as opposed to whole body dose. In this research, radiosensitive organ dose was estimated using Monte Carlo based simulations incorporating detailed multidetector CT (MDCT) scanner models, specific scan protocols, and using patient models based on accurate patient anatomy and representing a range of patient sizes. Organ dose estimates were estimated for clinical MDCT exam protocols which pose a specific concern for radiosensitive organs or regions. These dose estimates include estimation of fetal dose for pregnant patients undergoing abdomen pelvis CT exams or undergoing exams to diagnose pulmonary embolism and venous thromboembolism. Breast and lung dose were estimated for patients undergoing coronary CTA imaging, conventional fixed tube current chest CT, and conventional tube current modulated (TCM) chest CT exams. The correlation of organ dose with patient size was quantified for pregnant patients undergoing abdomen/pelvis exams and for all breast and lung dose estimates presented. Novel dose reduction techniques were developed that incorporate organ location and are specifically designed to reduce close to radiosensitive organs during CT acquisition. A generalizable model was created for simulating conventional and novel attenuation-based TCM algorithms which can be used in simulations estimating organ dose for any patient model. The generalizable model is a significant contribution of this work as it lays the foundation for the future of simulating TCM using Monte Carlo methods. As a result of this research organ dose can be estimated for individual patients undergoing specific conventional MDCT exams. This research also brings understanding to conventional and novel close reduction techniques in CT and their effect on organ dose.

  6. Occult pneumothorax in trauma patients: should this be sought in the focused assessment with sonography for trauma examination?

    PubMed

    Tam, Michael M K

    2005-01-01

    At present, CT scan is the gold standard for detecting occult traumatic pneumothorax not apparent on supine chest X-ray radiograph. Recently there were suggestions to expand focused assessment with sonography for trauma (FAST) to include thoracic ultrasound for detecting pneumothorax. The aim of the present study is to determine the incidence of occult pneumothorax (as shown by CT) in the subgroup of trauma patients undergoing FAST. Review of all trauma patients with FAST done from 1 June 2001 to 31 October 2002. Incidence of occult pneumothorax as diagnosed by CT was determined. Patients were not counted as having true occult pneumothorax if they had chest drains inserted before arrival or imaging studies. Selected clinical findings were tested for association with occult pneumothorax. In total, 143 patients underwent FAST, of whom 137 (95.8%) had chest X-ray examination performed. Of the 137 patients 59 required CT abdomen and/or thorax. Occult pneumothorax was found in three patients (2.1%). A history of thorax and/or abdominal injury plus one or more of: (i) mechanisms potentially causing major trauma; (ii) abnormal chest examination; and (iii) chest X-ray radiograph abnormality in the absence of pneumothorax, was significantly associated with the presence of occult pneumothorax (P = 0.03, Fisher's exact test; sensitivity: 100%; specificity: 71%; likelihood ratio: 3.42). The incidence of occult pneumothorax in the subgroup of trauma patients undergoing FAST is low. It implies that routine screening for its presence by adding thoracic ultrasound to FAST is unnecessary. Identifying those at risk of occult pneumothorax for further investigation appeared feasible.

  7. Prevalence of extravertebral cement leakage after vertebroplasty: procedural documentation versus CT detection.

    PubMed

    Martin, Douglas J; Rad, Arash Ehteshami; Kallmes, David F

    2012-06-01

    Reported incidence of extravertebral cement leakage after vertebroplasty varies widely across studies. To retrospectively compare the relative detection rates of extravertebral leakage noted under intra-procedural fluoroscopic surveillance, postprocedure plain radiographs, and postprocedure computed tomography (CT) in a cohort of patients undergoing vertebroplasty. With IRB approval, we retrospectively identified 181 patients with 277 levels treated with percutaneous vertebroplasty among a total of 1255 patients undergoing vertebroplasty between 1999 and 2010 who had subsequently undergone a CT examination that included the treated level(s). Categories of leakage were paravertebral, end plate, epidural, and prevertebral venous leakage. CT-detected leak rates were then compared to those noted on the vertebroplasty procedure reports and the archived fluoroscopic images for this same cohort using Pearson's χ(2) test. One hundred and forty-nine (82%, 95% CI 76-87%) of 181 patients demonstrated evidence of some type of leakage on CT at one or more treated levels. Sixty-two (34%, 95% CI 28-42%) and seventy-seven (50%, 95% CI 43-57%) of 149 CT-detected leaks were reported in the procedural dictation or detected on plain radiography (P = 0.01 and 0.006, respectively). The most common type of leakage noted on CT was end plate (n = 81, 45%, 95% CI 38-52%), followed by paravertebral (n = 64, 35%, 95% CI 29-43%), epidural (n = 36, 20%, 95% CI 15-26%), and prevertebral venous (n = 32, 18%, 95% CI 13-24%). Cement leakage after vertebroplasty is common and is often not reported by operators in procedural dictations. CT detects substantially more leaks than plain radiography.

  8. Diagnostic reference levels of paediatric computed tomography examinations performed at a dedicated Australian paediatric hospital.

    PubMed

    Bibbo, Giovanni; Brown, Scott; Linke, Rebecca

    2016-08-01

    Diagnostic Reference Levels (DRL) of procedures involving ionizing radiation are important tools to optimizing radiation doses delivered to patients and in identifying cases where the levels of doses are unusually high. This is particularly important for paediatric patients undergoing computed tomography (CT) examinations as these examinations are associated with relatively high-dose. Paediatric CT studies, performed at our institution from January 2010 to March 2014, have been retrospectively analysed to determine the 75th and 95th percentiles of both the volume computed tomography dose index (CTDIvol ) and dose-length product (DLP) for the most commonly performed studies to: establish local diagnostic reference levels for paediatric computed tomography examinations performed at our institution, benchmark our DRL with national and international published paediatric values, and determine the compliance of CT radiographer with established protocols. The derived local 75th percentile DRL have been found to be acceptable when compared with those published by the Australian National Radiation Dose Register and two national children's hospitals, and at the international level with the National Reference Doses for the UK. The 95th percentiles of CTDIvol for the various CT examinations have been found to be acceptable values for the CT scanner Dose-Check Notification. Benchmarking CT radiographers shows that they follow the set protocols for the various examinations without significant variations in the machine setting factors. The derivation of DRL has given us the tool to evaluate and improve the performance of our CT service by improved compliance and a reduction in radiation dose to our paediatric patients. We have also been able to benchmark our performance with similar national and international institutions. © 2016 The Royal Australian and New Zealand College of Radiologists.

  9. What is the underestimation of radiation dose to the pediatric thyroid gland from contrast enhanced CT, if contrast medium uptake is not taken into account?

    PubMed

    Perisinakis, Kostas; Pouli, Styliani; Tzedakis, Antonis; Spanakis, Kostas; Hatzidakis, Adam; Raissaki, Maria; Damilakis, John

    2018-05-01

    To assess the underestimation of radiation dose to the thyroid of children undergoing contrast enhanced CT if contrast medium uptake is not taken into account. 161 pediatric head, head & neck and chest CT examinations were retrospectively studied to identify those involving pre- and post-contrast imaging and thyroid inclusion in imaged volume. CT density of thyroid tissue in HU was measured in non-enhanced (NECT) and corresponding contrast-enhanced CT (CECT) images. Resulting CT number increase (ΔHU) was recorded for each patient and corresponded to a % w/w iodine concentration. The relation of %w/w iodine concentration to %dose increase induced by iodinated contrast uptake was derived by Monte Carlo simulation experiments. The thyroid gland was visible in 11 chest and 3 neck CT examinations involving both pre- and post-contrast imaging. The %w/w concentration of iodine in the thyroid tissue at the time of CECT acquisition was found to be 0.13%-0.58% w/w (mean = 0.26%). The %increase of dose to thyroid tissue was found to be linearly correlated to%w/w iodine uptake. The increase in radiation dose to thyroid due to contrast uptake ranged from 12% to 44%, with a mean value of 23%. The radiation dose to the pediatric thyroid from CECT exposure may be underestimated by up to 44% if contrast medium uptake is not taken into account. Meticulous demarcation of imaged volume in pediatric chest CT examinations is imperative to avoid unnecessary direct exposure of thyroid, especially in CT examinations following intravenous administration of contrast medium. Copyright © 2018 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  10. Accuracy of Ultrasonography and Computed Tomography in the Evaluation of Patients Undergoing Sialendoscopy for Sialolithiasis.

    PubMed

    Thomas, W Walsh; Douglas, Jennifer E; Rassekh, Christopher H

    2017-05-01

    Objective To determine the accuracy of the 2 most utilized imaging modalities in obstructive sialadenitis secondary to sialolithiasis-computed tomography (CT) and ultrasonography (US)-using sialendoscopic findings as a comparison standard. To review the impact of CT and US on the management of sialolithiasis managed with sialendoscopy alone and through combined approaches. Study Design Retrospective cohort study. Setting Quaternary academic referral center. Subjects and Methods All cases of patients undergoing sialendoscopy by a single surgeon for suspected parotid and submandibular gland pathology between the October 2013 and April 2016 were reviewed. Results Sixty-eight patients were in this cohort, of whom 44 underwent US, CT, and sialendoscopy; 20 underwent CT and sialendoscopy only; and 4 underwent US and sialendoscopy only. The sensitivity and specificity were 65% and 80% for US and 98% and 88% for CT, respectively. These 68 patients had 84 total stones addressed, with 79 being removed and 5 remaining in situ. The methods of stone removal were sialendoscopy alone (34 stones), open transoral approaches (36 stones), and an external approach: transcervical for submandibular and transfacial for parotid (11 stones). Conclusion US had a lower sensitivity (65%) than what has been reported in the literature (70%-94%), and the majority of missed stones were anterior Wharton's duct stones. These sialoliths were likely missed due to an incomplete examination. US and CT were complementary in this study, and the findings suggest that both modalities can be utilized to optimize the outcome of sialendoscopy and combined approaches.

  11. Performance of CT examinations in children with suspected acute appendicitis in the community setting: a need for more education.

    PubMed

    Kim, Michael E; Orth, Robert C; Fallon, Sara C; Lopez, Monica E; Brandt, Mary L; Zhang, Wei; Bisset, George S

    2015-04-01

    Despite a recent focus on the preferential use of ultrasound over CT for pediatric appendicitis, most children transferred from community hospitals still undergo diagnostic CT scans. The purpose of this study was to evaluate CT techniques performed for children with acute appendicitis at nonpediatric treatment centers. All patients treated for acute appendicitis at our tertiary-care pediatric hospital from July 1, 2011, through June 30, 2012, were identified. Patient demographics, imaging modality used to diagnoses appendicitis (CT or ultrasound), location (home or referral institution), and CT technique parameters were collected. The estimated mean organ radiation dose, number of imaging phases, and use of contrast media were evaluated at home and referral institutions. During the study period, 1215 patients underwent appendectomies after imaging, with 442 (36.4%) imaged at referral facilities. Most referral patients received a diagnosis by CT (n=384, 87%), compared with 73 of 773 (9.4%) who received a diagnosis by CT at the home institution. The estimated mean (±SD) organ radiation dose was not statistically significantly different between home and referral institutions (13.5±7.3 vs 12.9±6.4 mGy; p=0.58) for single-phase examinations. Of 384 referral patients, 344 had images available for review. In total, 40% (138/344) of patients from referral centers were imaged with suboptimal CT techniques: 50 delayed phase only, 52 dual phase (eight of which were imaged twice in delayed phase), eight triple phase, and 36 without IV contrast agent. CT parameters and radiation doses from single-phase examinations in children with appendicitis were similar at nonpediatric treatment centers and a tertiary care children's hospital. Future educational outreach should focus on optimizing other technical parameters.

  12. Absence of Intramolecular Singlet Fission in Pentacene-Perylenediimide Heterodimers: The Role of Charge Transfer State.

    PubMed

    Wang, Long; Wu, Yishi; Chen, Jianwei; Wang, Lanfen; Liu, Yanping; Yu, Zhenyi; Yao, Jiannian; Fu, Hongbing

    2017-11-16

    A new class of donor-acceptor heterodimers based on two singlet fission (SF)-active chromophores, i.e., pentacene (Pc) and perylenediimide (PDI), was developed to investigate the role of charge transfer (CT) state on the excitonic dynamics. The CT state is efficiently generated upon photoexcitation. However, the resulting CT state decays to different energy states depending on the energy levels of the CT state. It undergoes extremely rapid deactivation to the ground state in polar CH 2 Cl 2 , whereas it undergoes transformation to a Pc triplet in nonpolar toluene. The efficient triplet generation in toluene is not due to SF but CT-mediated intersystem crossing. In light of the energy landscape, it is suggested that the deep energy level of the CT state relative to that of the triplet pair state makes the CT state actually serve as a trap state that cannot undergoes an intramolecular singlet fission process. These results provide guidance for the design of SF materials and highlight the requisite for more widely applicable design principles.

  13. Fulminant clostridium difficile colitis: comparing computed tomography with histopathology: are they concordant?

    PubMed

    Felder, Seth I; Larson, Brent; Balzer, Bonnie; Wachsman, Ashley; Haker, Katherine; Fleshner, Phillip; Annamalai, Alagappan; Margulies, Daniel R

    2014-10-01

    A Total abdominal colectomy (TAC) is recommended for fulminant Clostridium difficile colitis (FCDC) because intraoperative assessment of diseased segments is inaccurate. To determine whether computerized tomography (CT) provides an accurate assessment of disease, we examined the concordance between CT and histopathologic colitis distribution in patients undergoing TAC for FCDC. The ileocolon was divided into seven distinct segments. Of 20 patients meeting criteria, the median interval between preoperative CT and TAC was 1.5 days (range, 0 to 23 days), and mortality was 65 per cent. The CT distribution of colitis was pancolitis in 12 patients and segmental in eight. Nine of the 12 patients with CT pancolitis had histologic pancolitis (75% concordance). Four of the eight patients with CT-diagnosed segmental disease had histologic segmental disease (50% concordance). For patients with FCDC, the distribution of colitis on CT agrees with the histopathologic extent of disease in the majority of patients. However, discordance between CT and histologic extent of disease was present in 25 to 50 per cent of patients. Therefore, the recommendation for TAC rather than segmental resection for FCDC remains justified.

  14. Diagnostic evaluation of ovarian torsion: An analysis of pediatric patients using the Nationwide Emergency Department Sample.

    PubMed

    Rialon, Kristy L; Wolf, Steven; Routh, Jonathan C; Adibe, Obinna O

    2017-04-01

    Ultrasonography (US) is the diagnostic modality of choice during work-up for ovarian torsion, although computed tomography (CT) may be used. We examined the utilization of CT in girls with ovarian torsion, and determined which patients are most likely to undergo this study. The Nationwide Emergency Department Sample dataset was searched for patients <18 years who presented with ovarian torsion from 2006 to 2012. Hospitals were categorized by the volume of pediatric patients seen. A total of 1279 patients were identified. Seven hundred twelve (56%) were seen at adult hospitals, 154 (12%) at pediatric privileged, and 413 (32%) at pediatric hospitals. Patients cared for in a pediatric or pediatric privileged hospital had more US alone performed to diagnose ovarian torsion (p < 0.01). Girls seen at pediatric hospitals are more likely to undergo US for work-up of ovarian torsion. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. ASSESSMENT OF CLINICAL IMAGE QUALITY IN PAEDIATRIC ABDOMINAL CT EXAMINATIONS: DEPENDENCY ON THE LEVEL OF ADAPTIVE STATISTICAL ITERATIVE RECONSTRUCTION (ASiR) AND THE TYPE OF CONVOLUTION KERNEL.

    PubMed

    Larsson, Joel; Båth, Magnus; Ledenius, Kerstin; Caisander, Håkan; Thilander-Klang, Anne

    2016-06-01

    The purpose of this study was to investigate the effect of different combinations of convolution kernel and the level of Adaptive Statistical iterative Reconstruction (ASiR™) on diagnostic image quality as well as visualisation of anatomical structures in paediatric abdominal computed tomography (CT) examinations. Thirty-five paediatric patients with abdominal pain with non-specified pathology undergoing abdominal CT were included in the study. Transaxial stacks of 5-mm-thick images were retrospectively reconstructed at various ASiR levels, in combination with three convolution kernels. Four paediatric radiologists rated the diagnostic image quality and the delineation of six anatomical structures in a blinded randomised visual grading study. Image quality at a given ASiR level was found to be dependent on the kernel, and a more edge-enhancing kernel benefitted from a higher ASiR level. An ASiR level of 70 % together with the Soft™ or Standard™ kernel was suggested to be the optimal combination for paediatric abdominal CT examinations. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. Radiation Dose Index of Renal Colic Protocol CT Studies in the United States

    PubMed Central

    Lukasiewicz, Adam; Bhargavan-Chatfield, Mythreyi; Coombs, Laura; Ghita, Monica; Weinreb, Jeffrey; Gunabushanam, Gowthaman; Moore, Christopher L.

    2016-01-01

    Purpose To determine radiation dose indexes for computed tomography (CT) performed with renal colic protocols in the United States, including frequency of reduced-dose technique usage and any institutional-level factors associated with high or low dose indexes. Materials and Methods The Dose Imaging Registry (DIR) collects deidentified CT data, including examination type and dose indexes, for CT performed at participating institutions; thus, the DIR portion of the study was exempt from institutional review board approval and was HIPAA compliant. CT dose indexes were examined at the institutional level for CT performed with a renal colic protocol at institutions that contributed at least 10 studies to the registry as of January 2013. Additionally, patients undergoing CT for renal colic at a single institution (with institutional review board approval and informed consent from prospective subjects and waiver of consent from retrospective subjects) were studied to examine individual renal colic CT dose index patterns and explore relationships between patient habitus, demographics, and dose indexes. Descriptive statistics were used to analyze dose indexes, and linear regression and Spearman correlations were used to examine relationships between dose indexes and institutional factors. Results There were 49 903 renal colic protocol CT examinations conducted at 93 institutions between May 2011 and January 2013. Mean age ± standard deviation was 49 years ± 18, and 53.9% of patients were female. Institutions contributed a median of 268 (interquartile range, 77–699) CT studies. Overall mean institutional dose-length product (DLP) was 746 mGy · cm (effective dose, 11.2 mSv), with a range of 307–1497 mGy · cm (effective dose, 4.6–22.5 mSv) for mean DLPs. Only 2% of studies were conducted with a DLP of 200 mGy · cm or lower (a “reduced dose”) (effective dose, 3 mSv), and only 10% of institutions kept DLP at 400 mGy · cm (effective dose, 6 mSv) or less in at least 50% of patients. Conclusion Reduced-dose renal protocol CT is used infrequently in the United States. Mean dose index is higher than reported previously, and institutional variation is substantial. PMID:24484064

  17. NCICT: a computational solution to estimate organ doses for pediatric and adult patients undergoing CT scans.

    PubMed

    Lee, Choonsik; Kim, Kwang Pyo; Bolch, Wesley E; Moroz, Brian E; Folio, Les

    2015-12-01

    We developed computational methods and tools to assess organ doses for pediatric and adult patients undergoing computed tomography (CT) examinations. We used the International Commission on Radiological Protection (ICRP) reference pediatric and adult phantoms combined with the Monte Carlo simulation of a reference CT scanner to establish comprehensive organ dose coefficients (DC), organ absorbed dose per unit volumetric CT Dose Index (CTDIvol) (mGy/mGy). We also developed methods to estimate organ doses with tube current modulation techniques and size specific dose estimates. A graphical user interface was designed to obtain user input of patient- and scan-specific parameters, and to calculate and display organ doses. A batch calculation routine was also integrated into the program to automatically calculate organ doses for a large number of patients. We entitled the computer program, National Cancer Institute dosimetry system for CT(NCICT). We compared our dose coefficients with those from CT-Expo, and evaluated the performance of our program using CT patient data. Our pediatric DCs show good agreements of organ dose estimation with those from CT-Expo except for thyroid. Our results support that the adult phantom in CT-Expo seems to represent a pediatric individual between 10 and 15 years rather than an adult. The comparison of CTDIvol values between NCICT and dose pages from 10 selected CT scans shows good agreements less than 12% except for two cases (up to 20%). The organ dose comparison between mean and modulated mAs shows that mean mAs-based calculation significantly overestimates dose (up to 2.4-fold) to the organs in close proximity to lungs in chest and chest-abdomen-pelvis scans. Our program provides more realistic anatomy based on the ICRP reference phantoms, higher age resolution, the most up-to-date bone marrow dosimetry, and several convenient features compared to previous tools. The NCICT will be available for research purpose in the near future.

  18. New diagnostic pathways urgently needed. Protocol of PET Guidance I pilot study: positron emission tomography in suspected cardiac implantable electronic device-related infection.

    PubMed

    Marciniak-Emmons, Marta Barbara; Sterliński, Maciej; Syska, Paweł; Maciąg, Aleksander; Farkowski, Michał Mirosław; Firek, Bohdan; Dziuk, Mirosław; Zając, Dariusz; Pytkowski, Mariusz; Szwed, Hanna

    2016-01-01

    Cardiovascular implantable electronic device (CIED) infection is a complication of increasing incidence. We present a protocol of an observational case control clinical trial "Positron Emission Tomography Combined With Computed Tomography (PET CT) in Suspected Cardiac Implantable Electronic Device Infection, a Pilot Study - PET Guidance I" (NCT02196753). The aim of this observational clinical trial is to assess and standardise diagnostic algorithms for CIED infections (lead-dependent infective endocarditis, generator pocket infection, fever of unknown origin) with PET CT in Poland. Study group will consist of 20 patients with initial diagnosis of CIED-related infection paired with a control group of 20 patients with implanted CIEDs, who underwent PET CT due to other non-infectious indications and have no data for infectious process in follow-up. All patients included in the study will undergo standard diagnostic pro-cess. Conventional/standard diagnostic and therapeutic process will consist of: medical interview, physical examination, laboratory tests, blood cultures; imaging studies: echocardiography: transthoracic (TTE), and, if there are no contraindications transoesophageal, computed tomography scan for pulmonary embolism if indicated; if there are abnormalities in other systems, decisions concerning further diagnostics will be made at the physician's discretion. As well as standard diagnostic procedures, patients will undergo whole body PET CT scan to localise infection or inflammation. Diagnosis and therapeutic decision will be obtained from the Study Committee. Follow-up will be held within six months with control visits at three and six months. During each follow-up visit, all patients will undergo laboratory tests, two blood cultures collected 1 h apart, and TTE. In case of actual clinical suspicion of infective endocarditis or local generator pocket infection, patients will be referred for further diagnostics. Endpoints for the results assessment - primary endpoints are to standardise PET CT in the diagnostic process: sensitivity, specificity, positive predictive value, and negative predictive value of the diagnosis made by PET CT; secondary endpoints are: assessment of usefulness of PET CT for detection of remote infective complications (metastatic abscesses, infected pulmonary emboli), incidence of particular localisations of infection, influence of PET CT on therapeutic decision: confirmation or change of decision based on PET CT, safety and complications of diagnostic process of CIED-related infections with PET CT. Evaluation of PET CT use for device-related infections in a case control study may be conclusive and improve diagnostic pathway.

  19. Influence of Parathyroidectomy on Bone Calcium Concentration: Evaluation with Spectral CT in Patients with Secondary Hyperparathyroidism Undergoing Hemodialysis-A Prospective Feasibility Study.

    PubMed

    Ma, Qiang; Yang, Zhenghan; Han, Xue; Liu, Fen; Su, Dechun; Xing, Haidong

    2017-07-01

    Purpose To use spectral computed tomography (CT) to evaluate the influence of parathyroidectomy (PTX) on calcium concentration in trabecular bone and cortical bone in patients undergoing hemodialysis with secondary hyperparathyroidism. Materials and Methods This study was performed with institutional review board approval. Written consent was obtained from each patient. Thirty-eight men (mean age ± standard deviation, 55.69 years ± 8.05; range, 42-72 years) undergoing maintenance hemodialysis who underwent PTX and 40 patients (mean age, 56.71 years ± 9.53; range, 45-74 years) who did not undergo PTX received prospective follow-up for 2 years. Bone calcium concentration was measured in the cortical compartment of the bilateral proximal femur and the medullary compartment of the lumbar vertebral bodies (L1 through L3) on the basis of calcium-based material decomposition images of a spectral CT examination. The differences between baseline and end-of-study PTX parameters were analyzed with the paired Student t test. Results For patients who underwent PTX, mean cortical bone calcium concentration increased from 220.69 mg/cm 3 ± 25.79 to 257.43 mg/cm 3 ± 25.46 (t = 8.546, P < .001), whereas medullary bone calcium concentration decreased from 64.75 mg/cm 3 ± 15.07 to 61.42 mg/cm 3 ± 15.77 (t = 22.293, P < .001) from baseline to follow-up. In patients who did not undergo PTX, mean cortical bone calcium concentration decreased from 296.08 mg/cm 3 ± 36.35 to 258.35 mg/cm 3 ± 31.46 (t = 7.420, P < .001), but medullary bone calcium concentration increased from 61.13 mg/cm 3 ± 13.85 to 62.94 mg/cm 3 ± 14.80 (t = 2.370, P = .023) from baseline to follow-up. Conclusion During the course of chronic renal failure, different bone elements involve various pathologic changes. PTX could reverse long-term cortical bone loss reflected in calcium concentration measured with spectral CT; however, it could induce medullary bone loss. © RSNA, 2017 Online supplemental material is available for this article.

  20. Perioperative patient radiation exposure in the endoscopic removal of upper urinary tract calculi.

    PubMed

    Jamal, Joseph E; Armenakas, Noel A; Sosa, R Ernest; Fracchia, John A

    2011-11-01

    The efficacy of computed tomography (CT) in detailing upper urinary tract calculi is well established. There is no established acceptable annual recommended limit for medical exposure, yet the global accepted upper limit for occupational radiation exposure is <50 millisieverts (mSv) in any one year. We sought to appreciate the CT and fluoroscopic radiation exposure to our patients undergoing endoscopic removal of upper tract calculi during the periprocedure period. All patients undergoing upper urinary endoscopic stone removal between 2005 and 2009 were identified. To calculate the cumulative radiation exposure, we included all ionizing radiation imaging performed during a periprocedure period, which we defined as ≤90 days pre- and post-therapeutic procedure. A total of 233 upper urinary tract therapeutic patient stone procedures were identified; 127 patients underwent ureteroscopy (URS) and 106 patients underwent percutaneous nephrolithotomy (PCNL). A mean 1.58 CTs were performed per patient. Ninety (38.6%) patients underwent ≥2 CTs in the periprocedure period, with an average number in this group of 2.49 CT/patient, resulting in approximately 49.8 mSv of CT radiation exposure. Patients who were undergoing URS were significantly more likely to have multiple CTs (P=0.003) than those undergoing PCNL. Median fluoroscopic procedure exposures were 43.3 mGy for patients who were undergoing PCNL and 27.6 mGy for those patients undergoing URS. CT radiation exposure in the periprocedure period for patients who were undergoing endoscopic upper tract stone removal is considerable. Added to this is the procedure-related fluoroscopic radiation exposure. Urologic surgeons should be aware of the cumulative amount of ionizing radiation received by their patients from multiple sources.

  1. Molecular imaging of malignant tumor metabolism: whole-body image fusion of DWI/CT vs. PET/CT.

    PubMed

    Reiner, Caecilia S; Fischer, Michael A; Hany, Thomas; Stolzmann, Paul; Nanz, Daniel; Donati, Olivio F; Weishaupt, Dominik; von Schulthess, Gustav K; Scheffel, Hans

    2011-08-01

    To prospectively investigate the technical feasibility and performance of image fusion for whole-body diffusion-weighted imaging (wbDWI) and computed tomography (CT) to detect metastases using hybrid positron emission tomography/computed tomography (PET/CT) as reference standard. Fifty-two patients (60 ± 14 years; 18 women) with different malignant tumor disease examined by PET/CT for clinical reasons consented to undergo additional wbDWI at 1.5 Tesla. WbDWI was performed using a diffusion-weighted single-shot echo-planar imaging during free breathing. Images at b = 0 s/mm(2) and b = 700 s/mm(2) were acquired and apparent diffusion coefficient (ADC) maps were generated. Image fusion of wbDWI and CT (from PET/CT scan) was performed yielding for wbDWI/CT fused image data. One radiologist rated the success of image fusion and diagnostic image quality. The presence or absence of metastases on wbDWI/CT fused images was evaluated together with the separate wbDWI and CT images by two different, independent radiologists blinded to results from PET/CT. Detection rate and positive predictive values for diagnosing metastases was calculated. PET/CT examinations were used as reference standard. PET/CT identified 305 malignant lesions in 39 of 52 (75%) patients. WbDWI/CT image fusion was technically successful and yielded diagnostic image quality in 73% and 92% of patients, respectively. Interobserver agreement for the evaluation of wbDWI/CT images was κ = 0.78. WbDWI/CT identified 270 metastases in 43 of 52 (83%) patients. Overall detection rate and positive predictive value of wbDWI/CT was 89% (95% CI, 0.85-0.92) and 94% (95% CI, 0.92-0.97), respectively. WbDWI/CT image fusion is technically feasible in a clinical setting and allows the diagnostic assessment of metastatic tumor disease detecting nine of 10 lesions as compared with PET/CT. Copyright © 2011 AUR. Published by Elsevier Inc. All rights reserved.

  2. German cardiac CT registry: indications, procedural data and clinical consequences in 7061 patients undergoing cardiac computed tomography.

    PubMed

    Marwan, Mohamed; Achenbach, Stephan; Korosoglou, Grigorios; Schmermund, Axel; Schneider, Steffen; Bruder, Oliver; Hausleiter, Jörg; Schroeder, Stephen; Barth, Sebastian; Kerber, Sebastian; Leber, Alexander; Moshage, Werner; Senges, Jochen

    2018-05-01

    Cardiac computed tomography permits quantification of coronary calcification as well as detection of coronary artery stenoses after contrast enhancement. Moreover, cardiac CT offers high-resolution morphologic and functional imaging of cardiac structures which is valuable for various structural heart disease interventions and electrophysiology procedures. So far, only limited data exist regarding the spectrum of indications, image acquisition parameters as well as results and clinical consequences of cardiac CT examinations using state-of-the-art CT systems in experienced centers. Twelve cardiology centers with profound expertise in cardiovascular imaging participated in the German Cardiac CT Registry. Criteria for participation included adequate experience in cardiac CT as well of the availability of a 64-slice or newer CT system. Between 2009 and 2014, 7061 patients were prospectively enrolled. For all cardiac CT examinations, patient parameters, procedural data, indication and clinical consequences of the examination were documented. Mean patient age was 61 ± 12 years, 63% were males. The majority (63%) of all cardiac CT examinations were performed in an outpatient setting, 37% were performed during an inpatient stay. 91% were elective and 9% were scheduled in an acute setting. In most examinations (48%), reporting was performed by cardiologists, in 4% by radiologists and in 47% of the cases as a consensus reading. Cardiac CT was limited to native acquisitions for assessment of coronary artery calcification in 9% of patients, only contrast-enhanced coronary CT angiography was performed in 16.6% and combined native and contrast-enhanced coronary CT angiography was performed in 57.7% of patients. Non-coronary cardiac CT examinations constituted 16.6% of all cases. Coronary artery calcification assessment was performed using prospectively ECG-triggered acquisition in 76.9% of all cases. The median dose length product (DLP) was 42 mGy cm (estimated effective radiation dose of 0.6 mSv). Coronary CT angiography was performed using prospectively ECG-triggered acquisition in 77.3% of all cases. Tube voltage was 120 kV in 67.8% of patients and 100 kV in 30.7% of patients, with a resultant median DLP of 256 mGy cm (estimated effective dose of 3.6 mSv). Clinical consequences of cardiac CT were as follows: in 46.8% of the cases, invasive coronary angiography could be avoided; ischemia testing was recommended in 4.7% of the cases, invasive coronary angiography was recommended in 16.4% of the cases and change in medication in 21.6% of the examinations. Cardiac CT is performed in the majority of patients for non-invasive evaluation of the coronary arteries. CT frequently resulted in medication change, and otherwise planned downstream testing including invasive angiography could be avoided in a high percentage of patients. Radiation exposure in experienced centers is relatively low.

  3. Patients with cervical Ureaplasma Urealyticum and Chlamydia Trachomatis infection undergoing IVF/ICSI-ET: The need for new paradigm.

    PubMed

    Xie, Qing-Zhen; Xu, Wang-Ming; Qi, Qian-Rong; Luo, Zeng-Li; Dong, Lan

    2016-10-01

    Genital tract infections with ureaplasma urealyticum (UU) and chlamydia trachomatis (CT) are the most frequent sexually-transmitted disease worldwide. UU and CT infections are considered to be the leading cause for infertility and adverse pregnancy outcomes. However, little is known about the specific effect of cervical UU and CT infections on the etiology of female infertility, as well as the pregnancy outcomes of the patients undergoing in vitro fertilization/intracytoplasmic sperm injection-embryo transfer (IVF/ICSI-ET). In order to find the association between cervical UU and/or CT infection and pregnancy outcomes, we conducted a retrospective case-control study on the patients undergoing IVF/ICSI-ET with cervical UU and/or CT infection. A total of 2208 patients who received IVF/ICSI-ET were enrolled in this study. Data on the general conditions, pregnancy history and clinical pregnant outcomes were analyzed in terms of the cervical UU and CT detection. Our results revealed that cervical UU and CT infections were the risk factors for ectopic pregnancy and tubal factor-induced infertility. Moreover, the pregnancy rate, abortion rate, ectopic pregnancy rate and premature birth rate in patients with UU and/or CT infections showed no significant difference when compared with the control group. We recommend that cervical UU and CT detection should be an optional item for infertility patients and clinical UU detection should differentiate the subtypes of cervical UU. Positive cervical UU and CT infections should not be taken as strict contraindications for IVF/ICSI-ET.

  4. The utility of noncontrast computed tomography in the prompt diagnosis of postoperative complications after percutaneous nephrolithotomy.

    PubMed

    Gnessin, Ehud; Mandeville, Jessica A; Handa, Shelly E; Lingeman, James E

    2012-04-01

    Noncontrast computed tomography (CT) is commonly utilized after percutaneous nephrolithotomy (PNL) to assess stone-free (SF) status. In addition to assessing SF status, CT is useful in the recognition of complications after PNL. We characterized complications demonstrated by postoperative CT scan and compared hospital re-admission rates based on whether or not CT was performed. We retrospectively reviewed records of 1032 consecutive patients from April 1999 to June 2010. Patients were divided into two cohorts based on whether they had a CT within 24 hours of PNL. Demographic data, CT findings, and need for re-admission for complication management were assessed. Nine hundred fifty-seven patients (92.7%) underwent post-PNL CT. CT-diagnosed complications were perinephric hematoma in 41 (4.3%; 2 requiring embolization and 9 necessitating transfusion), pleural effusion in 25 (2.6%; 10 requiring intervention), colon perforation in 2 (0.2%), and splenic injury in 2 (0.2%). Of patients with postoperative complications, 33% required intervention. Among patients with a CT, 6 (0.6%) were readmitted despite negative postoperative CT (four perinephric hematomas, one calyceal-pleural fistula, and one pseudoaneurysm). The sensitivity of CT for diagnosing complications was 92.7%. Seventy-five patients (7.3%) did not undergo CT post-PNL. Of these, four (5.33%) were readmitted: three for perinephric hematomas and one for ureteral clot obstruction. Patients undergoing post-PNL CT were less likely to be readmitted because of missed complications (p=0.02). Serious post-PNL complications are uncommon, but their prompt diagnosis and treatment is imperative. In addition to identifying residual stones, CT is useful in diagnosing postoperative complications. Postoperative CT could potentially be considered for all patients undergoing PNL, particularly in complex cases such as patients with anatomical abnormalities (renal anatomic abnormality or retrorenal colon), patients requiring upper pole access (risk of thoracic, hepatic, and splenic complications), and patients requiring multisite access (higher risk of perinephric hematoma or need for transfusion).

  5. Evaluation of the radiation doses in newborn patients submitted to CT examinations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    De Souza Santos, William; Caldas, Linda V.E.; Belinato, Walmir

    The number of computed tomography (CT) scans available to the population is increasing, as well as the complexity of such exams. As a result, the radiation doses are increasing as well. Considering the population exposed to CT exams, pediatric patients are considerably more sensitive to radiation than adults. They have a longer life expectancy than adults, and may receive a higher radiation dose than necessary if the CT scan settings are not adjusted for their smaller body size. As a result of these considerations, the risk of developing cancer is of great concern when newborn patients are involved. The objectivemore » of this work was to study the radiation doses on radiosensitive organs of newborn patients undergoing a whole body CT examination, utilizing Monte Carlo simulations. The novelty of this work is the use of pediatric virtual anthropomorphic phantoms, developed at the Department of Nuclear Energy at the Federal University of Pernambuco (DEN/UFPE). The CT equipment utilized during the simulations was a Discovery VCT GE PET/CT system, with a tube voltage of 140 kVp. The X-ray spectrum of this CT scanner was generated by the SRS-78 software, which takes into account the X-ray beam energy used in PET/CT procedures. The absorbed organ doses were computed employing the F6 tally (MeV/g). The results were converted to dose coefficients (mGy/100 mA) for all the structures, considering all employed beams. The highest dose coefficients values were obtained for the brain and the thyroid. This work provides useful information regarding the risks involving ionizing radiation in newborn patients, employing a new and reliable technique. (authors)« less

  6. Estimating Radiation Dose Metrics for Patients Undergoing Tube Current Modulation CT Scans

    NASA Astrophysics Data System (ADS)

    McMillan, Kyle Lorin

    Computed tomography (CT) has long been a powerful tool in the diagnosis of disease, identification of tumors and guidance of interventional procedures. With CT examinations comes the concern of radiation exposure and the associated risks. In order to properly understand those risks on a patient-specific level, organ dose must be quantified for each CT scan. Some of the most widely used organ dose estimates are derived from fixed tube current (FTC) scans of a standard sized idealized patient model. However, in current clinical practice, patient size varies from neonates weighing just a few kg to morbidly obese patients weighing over 200 kg, and nearly all CT exams are performed with tube current modulation (TCM), a scanning technique that adjusts scanner output according to changes in patient attenuation. Methods to account for TCM in CT organ dose estimates have been previously demonstrated, but these methods are limited in scope and/or restricted to idealized TCM profiles that are not based on physical observations and not scanner specific (e.g. don't account for tube limits, scanner-specific effects, etc.). The goal of this work was to develop methods to estimate organ doses to patients undergoing CT scans that take into account both the patient size as well as the effects of TCM. This work started with the development and validation of methods to estimate scanner-specific TCM schemes for any voxelized patient model. An approach was developed to generate estimated TCM schemes that match actual TCM schemes that would have been acquired on the scanner for any patient model. Using this approach, TCM schemes were then generated for a variety of body CT protocols for a set of reference voxelized phantoms for which TCM information does not currently exist. These are whole body patient models representing a variety of sizes, ages and genders that have all radiosensitive organs identified. TCM schemes for these models facilitated Monte Carlo-based estimates of fully-, partially- and indirectly-irradiated organ dose from TCM CT exams. By accounting for the effects of patient size in the organ dose estimates, a comprehensive set of patient-specific dose estimates from TCM CT exams was developed. These patient-specific organ dose estimates from TCM CT exams will provide a more complete understanding of the dose impact and risks associated with modern body CT scanning protocols.

  7. Follow-up CT findings of tamoxifen-induced non-alcoholic steatohepatitis (NASH) of breast cancer patients treated with bezafibrate.

    PubMed

    Ogawa, Yasuhiro; Murata, Yoriko; Saibara, Toshiji; Nishioka, Akihito; Kariya, Shinji; Yoshida, Shoji

    2003-01-01

    One-third of the breast cancer patients who underwent tamoxifen intake showed less than 0.9 of their liver/spleen CT (computed tomography) ratio on their annual CT study, and were diagnosed as having fatty liver (hepatic steatosis). Among them, patients who showed a lower liver/spleen CT ratio of less than 0.5 were recommended to undergo needle biopsy of the liver in order to obtain histopathological confirmation of non-alcoholic steatohepatitis (NASH), with 15 patients undergoing needle biopsy of the liver. As a result, 14 out of the 15 patients were diagnosed as having NASH, and these patients were additionally administered bezafibrate in order to prevent possible progressive changes of NASH into liver cirrhosis. In this study, we show the changes of follow-up CT findings of 6 patients with histopathologically-proven NASH who continued to undergo bezafibrate intake after the diagnosis of NASH. Two patients showed almost complete improvement as indicated by the liver/spleen CT ratio several months after completion of a tamoxifen intake of 5 years, and another 3 showed partial improvement on their liver/spleen CT ratio by bezafibrate intake in spite of continuing tamoxifen intake. Another patient with diabetes mellitus (type II) showed a continually decreasing liver/spleen CT ratio during adjuvant tamoxifen in spite of bezafibrate intake. Therefore, we concluded that the progression of NASH could be prevented by bezafibrate without any interruption of adjuvant tamoxifen treatment. For patients with diabetes mellitus, critical follow-up using CT study and laboratory tests is considered essential.

  8. Evaluation of thromboelastometry parameters as predictive markers for sinusoidal obstruction syndrome in patients undergoing allogeneic stem cell transplantation for acute leukaemia

    PubMed Central

    Rupa-Matysek, Joanna; Gil, Lidia; Wojtasińska, Ewelina; Kanduła, Zuzanna; Nowicki, Adam; Matuszak, Magdalena; Komarnicki, Mieczysław

    2017-01-01

    Hepatic sinusoidal obstruction syndrome (previously named veno-occlusive disease, SOS/VOD) is a serious complication of allogeneic stem cell transplantation (HSCT). Early identification of patients at risk of SOS/VOD may possibly improve the outcome and reduce mortality. Rotation thromboelastometry (ROTEM) is global assay allowing for the precise assessment of both bleeding and thrombotic conditions, however, its usefulness in patients undergoing HSCT for acute leukaemia has not been studied. We evaluated the thromboelastometry parameters in patients undergoing allogeneic HSCT for acute leukaemia to identify candidate biomarkers of SOS/VOD occurrence. ROTEM assays (INTEM, EXTEM, FIBTEM, APTEM) were performed on day -10, on the day of stem cell infusion (day 0) and on days +12 and +28 post-HSCT. The diagnosis of SOS/VOD was based on the Baltimore criteria. Seven patients (26%) developed SOS/VOD. On day +12, the patients with SOS/VOD had statistically significant longer INTEM-CT (clotting time, 199 ± 33.41vs166 ± 23.65s, p = 0.0033), EXTEM-CT (69.5 ± 6.39vs.52 ± 3.42s, p = 0.0139) and FIBTEM-CT (69.5 ± 22.75vs. 50.8 ± 14.31s, p = 0.0124) compared to SOS/VOD (-). ROC curve on day +12 indicated a cut-off value of 179s in INTEM-CT (AUC = 0.91), 69s in EXTEM-CT (AUC = 0.90) and 102s in FIBTEM-CT (AUC = 0.82) for the prediction of SOS/VOD. This is the first study evaluating the usefulness of ROTEM assays in the early detection of haemostasis abnormalities predictive of SOS/VOD development in patients undergoing HSCT for acute leukemia. Patients with SOS/VOD had a significant delay in the initiation of thrombin formation in the analysed ROTEM assays. The utility of ROTEM assays in the optimal management of patients undergoing HSCT should be clarified in further prospective studies. PMID:28938703

  9. Comparison of the incidence of postoperative hypocalcemia following total thyroidectomy vs completion thyroidectomy.

    PubMed

    Merchavy, Shlomo; Marom, Tal; Forest, Veronique-Isabelle; Hier, Michael; Mlynarek, Alex; McHugh, Tobial; Payne, Richard

    2015-01-01

    To study the rate of postoperative hypocalcemia following completion thyroidectomy (CT), in comparison with the hypocalcemia rate following total thyroidectomy (TT). A retrospective study, performed at the McGill University Thyroid Cancer Center, Montreal, Quebec, Canada, from 2007 to 2012. Medical records of adult patients undergoing CT and TT operated by a single surgeon were reviewed. Data were extracted for demographics, postoperative calcium levels, surgical logs, and final surgical pathology. Hypocalcemia was defined as corrected serum calcium level ≤ 1.90 mmol/L, with concurrent serum parathyroid hormone <8 ng/L, and/or any signs or symptoms of hypocalcemia. There were 68 CTs and 146 TTs. Transient hypocalcemia occurred in 1 of 68 (1.5%) and 18 of 146 (12.5%) patients in the CT and TT groups, respectively. The rate of hypocalcemia was significantly lower in the CT compared with the TT group (P = .02). In both groups, there were no cases of permanent hypocalcemia. The risk of transient of hypocalcemia in patients undergoing CT is significantly lower than the rate of hypocalcemia in patients undergoing TT. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2014.

  10. Investigating the necessity of computed tomographic scans in children with headaches: a retrospective review.

    PubMed

    Gandhi, Rohit; Lewis, Evan Cole; Evans, Jeanette W; Sell, Erick

    2015-03-01

    Headaches are a common problem in the pediatric population. In 2002, the American Academy of Neurology (AAN) developed guidelines on neuroimaging for patients presenting with headache. Our objective was to determine the frequency of computed tomographic (CT) scanning ordered by a range of medical practitioners for pediatric patients presenting with primary headache. A retrospective chart review was conducted at the Children's Hospital of Eastern Ontario (CHEO), a tertiary care centre in Ontario. One hundred fifty-one records of patients referred to the outpatient neurology clinic at CHEO with ''headache'' or ''migraine'' as the primary complaint from 2004 to 2009 were randomly selected. Ninety-nine patients with normal neurologic examinations were ultimately included. Thirty-four patients (34%; 95% CI 25-45) had undergone CT scanning. None of the 34 CT scans (0%; 95% CI 0-10) showed significant findings, and none changed the headache diagnosis or management. Eleven (32%) of the CT scans were ordered by CHEO neurologists, 15 (44%) by community physicians, and 8 (24%) by CHEO emergency physicians. A high proportion of children presenting with primary headaches and a normal neurologic examination undergo CT scanning, despite well-established AAN guidelines regarding neuroimaging. Most of these CT scans do not appear to alter diagnosis and management. A variety of non-evidencebased factors may be encouraging physicians to overinvestigate this population and, as a result, increasing the risk of adverse events due to radiation exposure. Implementing initiatives at a site-based level that promote the use of established guidelines before performing CT scanning in this population may be beneficial.

  11. Establishing national diagnostic reference levels (DRLs) for computed tomography in Egypt.

    PubMed

    Salama, Dina Husseiny; Vassileva, Jenia; Mahdaly, Gamal; Shawki, Mona; Salama, Ahmad; Gilley, Debbie; Rehani, Madan Mohan

    2017-07-01

    To establish national diagnostic reference levels (DRLs) in Egypt for computed tomography (CT) examinations of adults and identify the potential for optimization. Data from 3762 individual patient's undergoing CT scans of head, chest (high resolution), abdomen, abdomen-pelvis, chest-abdomen-pelvis and CT angiography (aorta and both lower limbs) examinations in 50 CT facilities were collected. This represents 20% of facilities in the country and all of the 27 Governorates. Results were compared with DRLs of UK, USA, Canada, Japan, Australia and France. The Egyptian DRLs for CTDI vol in mGy are for head: 30, chest (high resolution): 22, abdomen (liver metastasis): 31, abdomen-pelvis: 31, chest-abdomen-pelvis: 33 and CT angiography (aorta and lower limbs): 37. The corresponding DRLs for DLP in mGy.cm are 1360, 420, 1425, 1325, 1320 and 1320. For head CT, the Egyptian DRL for CTDI vol is 2-3 times lower than the DRLs from other countries. However, the DRL in terms of DLP is in the same range or higher as compared to others. The Egyptian DRL for chest CT (high resolution) is similar to others for DLP but higher for CTDI vol . For abdomen and abdomen-pelvis DRLs for CTDI vol are higher than others. For DLP, the DRLs for abdomen are higher than DRL in UK and lower than those in Japan, while for abdomen-pelvis they are higher than other countries. Despite lower DRLs for CTDI vol , an important consistent problem appears to be higher scan range as DRLs for DLP are higher. Copyright © 2017 Associazione Italiana di Fisica Medica. All rights reserved.

  12. Patient size and x-ray transmission in body CT.

    PubMed

    Ogden, Kent; Huda, Walter; Scalzetti, Ernest M; Roskopf, Marsha L

    2004-04-01

    Physical characteristics were obtained for 196 patients undergoing chest and abdomen computed tomography (CT) examinations. Computed tomography sections for these patients having no evident pathology were analyzed to determine patient dimensions (AP and lateral), together with the average attenuation coefficient. Patient weights ranged from approximately 3 kg to about 120 kg. For chest CT, the mean Hounsfield unit (HU) fell from about -120 HU for newborns to about -300 HU for adults. For abdominal CT, the mean HU for children and normal-sized adults was about 20 HU, but decreased to below -50 HU for adults weighing more than 100 kg. The effective photon energy and percent energy fluence transmitted through a given patient size and composition was calculated for representative x-ray spectra at 80, 100, 120, and 140 kV tube potentials. A 70-kg adult scanned at 120 kVp transmits 2.6% of the energy fluence for chest and 0.7% for abdomen CT examinations. Reducing the patient size to 10 kg increases transmission by an order of magnitude. For 70 kg patients, effective energies in body CT range from approximately 50 keV at 80 kVp to approximately 67 keV at 140 kVp; increasing patient size from 10 to 120 kg resulted in an increase in effective photon energy of approximately 4 keV. The x-ray transmission data and effective photon energy data can be used to determine CT image noise and image contrast, respectively, and information on patient size and composition can be used to determine patient doses.

  13. Correlation of B-Lines on Ultrasonography With Interstitial Lung Disease on Chest Radiography and CT Imaging.

    PubMed

    Dubinsky, Theodore J; Shah, Hardik; Sonneborn, Rachelle; Hippe, Daniel S

    2017-11-01

    We prospectively identified B-lines in patients undergoing ultrasonographic (US) examinations following liver transplantation who also had chest radiography (CXR) or chest CT imaging, or both, on the same day to determine if an association between the presence of B-lines from the thorax on US images correlates with the presence of lung abnormalities on CXR. Following institutional review board (IRB) approval, patients who received liver transplants and underwent routine US examinations and chest radiography or CT imaging, or both, on the same day between January 1, 2015 through July 1, 2016 were prospectively identified. Two readers who were blinded to chest films and CT images and reports independently reviewed the US interreader agreement for the presence or absence of B-lines and performed an evaluation for the presence or absence of diffuse parenchymal lung disease (DPLD) on chest films and CT images as well as from clinical evaluation. Receiver operating characteristic (ROC) curves were constructed. There was good agreement between the two readers on the presence of absence of B-lines (kappa = 0.94). The area under the ROC curve for discriminating between positive DPLD and negative DPLD for both readers was 0.79 (95% CI, 0.71-0.87). There is an association between the presence of extensive B-lines to the point of confluence and "dirty shadowing" on US examinations of the chest and associated findings on chest radiographs and CT scans of DPLD. Conversely, isolated B-lines do not always correlate with abnormalities on chest films and in fact sometimes appear to be a normal variant. Copyright © 2017 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.

  14. Utility of MRI for cervical spine clearance in blunt trauma patients after a negative CT.

    PubMed

    Malhotra, Ajay; Durand, David; Wu, Xiao; Geng, Bertie; Abbed, Khalid; Nunez, Diego B; Sanelli, Pina

    2018-07-01

    To determine the utility of cervical spine MRI in blunt trauma evaluation for instability after a negative non-contrast cervical spine CT. A review of medical records identified all adult patients with blunt trauma who underwent CT cervical spine followed by MRI within 48 h over a 33-month period. Utility of subsequent MRI was assessed in terms of findings and impact on outcome. A total of 1,271 patients with blunt cervical spine trauma underwent both cervical spine CT and MRI within 48 h; 1,080 patients were included in the study analysis. Sixty-six percent of patients with a CT cervical spine study had a negative study. Of these, the subsequent cervical spine MRI had positive findings in 20.9%; 92.6% had stable ligamentous or osseous injuries, 6.0% had unstable injuries and 1.3% had potentially unstable injuries. For unstable injury, the NPV for CT was 98.5%. In all 712 patients undergoing both CT and MRI, only 1.5% had unstable injuries, and only 0.42% had significant change in management. MRI for blunt trauma evaluation remains not infrequent at our institution. MRI may have utility only in certain patients with persistent abnormal neurological examination. • MRI has limited utility after negative cervical CT in blunt trauma. • MRI is frequently positive for non-specific soft-tissue injury. • Unstable injury missed on CT is infrequent.

  15. Is computed tomography a necessary part of a metastatic evaluation for castration-resistant prostate cancer? Results from the Shared Equal Access Regional Cancer Hospital Database.

    PubMed

    Hanyok, Brian T; Howard, Lauren E; Amling, Christopher L; Aronson, William J; Cooperberg, Matthew R; Kane, Christopher J; Terris, Martha K; Posadas, Edwin M; Freedland, Stephen J

    2016-01-15

    Metastatic lesions in prostate cancer beyond the bone have prognostic importance and affect clinical therapeutic decisions. Few data exist regarding the prevalence of soft-tissue metastases at the initial diagnosis of metastatic castration-resistant prostate cancer (mCRPC). This study analyzed 232 men with nonmetastatic (M0) castration-resistant prostate cancer (CRPC) who developed metastases detected by a bone scan or computed tomography (CT). All bone scans and CT scans within the 30 days before or after the mCRPC diagnosis were reviewed. The rate of soft-tissue metastases among those undergoing CT was determined. Then, predictors of soft-tissue metastases and visceral and lymph node metastases were identified. Compared with men undergoing CT (n = 118), men undergoing only bone scans (n = 114) were more likely to have received primary treatment (P = .048), were older (P = .013), and less recently developed metastases (P = .018). Among those undergoing CT, 52 (44%) had soft-tissue metastases, including 20 visceral metastases (17%) and 41 lymph node metastases (35%), whereas 30% had no bone involvement. In a univariable analysis, only prostate-specific antigen (PSA) predicted soft-tissue metastases (odds ratio [OR], 1.27; P = .047), and no statistically significant predictors of visceral metastases were found. A higher PSA level was associated with an increased risk of lymph node metastases (OR, 1.38; P = .014), whereas receiving primary treatment was associated with decreased risk (OR, 0.36; P = .015). The data suggest that there is a relatively high rate of soft-tissue metastasis (44%) among CRPC patients undergoing CT at the initial diagnosis of metastases, including some men with no bone involvement. Therefore, forgoing CT during a metastatic evaluation may lead to an underdiagnosis of soft-tissue metastases and an underdiagnosis of metastases in general. Cancer 2015. © 2015 American Cancer Society. Cancer 2016;122:222-229. © 2015 American Cancer Society. © 2015 American Cancer Society.

  16. PET/CT with 18F Fluorocholine as an Imaging Biomarker for Chronic Liver Disease: A Preliminary Radiopathologic Correspondence Study in Patients with Liver Cancer.

    PubMed

    Kwee, Sandi A; Wong, Linda; Chan, Owen T M; Kalathil, Sumodh; Tsai, Naoky

    2018-04-01

    Purpose To determine the relationship between hepatic uptake at preoperative fluorine 18 ( 18 F) fluorocholine combined positron emission tomography (PET) and computed tomography (CT) and the histopathologic features of chronic liver disease in patients with Child-Pugh class A or B disease who are undergoing hepatic resection for liver cancer. Materials and Methods Forty-eight patients with resectable liver tumors underwent preoperative 18 F fluorocholine PET/CT. Mean liver standardized uptake value (SUV mean ) measurements were obtained from PET images, while histologic indexes of inflammation and fibrosis were applied to nontumor liver tissue from resection specimens. Effects of histopathologic features on liver SUV mean were examined with analysis of variance. Results Liver SUV mean ranged from 4.3 to 11.6, correlating significantly with Knodell histologic activity index (ρ = -0.81, P < .001) and several clinical indexes of liver disease severity. Liver SUV mean also differed significantly across groups stratified by necroinflammatory severity and Metavir fibrosis stage (P < . 001). The area under the receiver operating characteristic curve for 18 F fluorocholine PET/CT detecting Metavir fibrosis stage F1 or higher was 0.89 ± 0.05, with an odds-ratio of 3.03 (95% confidence interval: 1.59, 5.88) and sensitivity and specificity of 82% and 93%, respectively. Conclusion Correlations found in patients undergoing hepatic resection for liver cancer between liver 18 F fluorocholine uptake and histopathologic indexes of liver fibrosis and inflammation support the use of 18 F fluorocholine PET/CT as a potential imaging biomarker for chronic liver disease. © RSNA, 2018.

  17. Development and validation of a GEANT4 radiation transport code for CT dosimetry

    PubMed Central

    Carver, DE; Kost, SD; Fernald, MJ; Lewis, KG; Fraser, ND; Pickens, DR; Price, RR; Stabin, MG

    2014-01-01

    We have created a radiation transport code using the GEANT4 Monte Carlo toolkit to simulate pediatric patients undergoing CT examinations. The focus of this paper is to validate our simulation with real-world physical dosimetry measurements using two independent techniques. Exposure measurements were made with a standard 100-mm CT pencil ionization chamber, and absorbed doses were also measured using optically stimulated luminescent (OSL) dosimeters. Measurements were made in air, a standard 16-cm acrylic head phantom, and a standard 32-cm acrylic body phantom. Physical dose measurements determined from the ionization chamber in air for 100 and 120 kVp beam energies were used to derive photon-fluence calibration factors. Both ion chamber and OSL measurement results provide useful comparisons in the validation of our Monte Carlo simulations. We found that simulated and measured CTDI values were within an overall average of 6% of each other. PMID:25706135

  18. Development and validation of a GEANT4 radiation transport code for CT dosimetry.

    PubMed

    Carver, D E; Kost, S D; Fernald, M J; Lewis, K G; Fraser, N D; Pickens, D R; Price, R R; Stabin, M G

    2015-04-01

    The authors have created a radiation transport code using the GEANT4 Monte Carlo toolkit to simulate pediatric patients undergoing CT examinations. The focus of this paper is to validate their simulation with real-world physical dosimetry measurements using two independent techniques. Exposure measurements were made with a standard 100-mm CT pencil ionization chamber, and absorbed doses were also measured using optically stimulated luminescent (OSL) dosimeters. Measurements were made in air with a standard 16-cm acrylic head phantom and with a standard 32-cm acrylic body phantom. Physical dose measurements determined from the ionization chamber in air for 100 and 120 kVp beam energies were used to derive photon-fluence calibration factors. Both ion chamber and OSL measurement results provide useful comparisons in the validation of the Monte Carlo simulations. It was found that simulated and measured CTDI values were within an overall average of 6% of each other.

  19. Should bedside sonography be used first to diagnose pneumothorax secondary to blunt trauma?

    PubMed

    Donmez, Halil; Tokmak, Turgut Tursem; Yildirim, Afra; Buyukoglan, Hakan; Ozturk, Mehmet; Yaşar Ayaz, Umit; Mavili, Ertugrul

    2012-01-01

    BACKGROUND.: Our purpose was to evaluate the effectiveness of bedside sonography (US) in the detection of pneumothorax secondary to blunt thoracic trauma. METHODS.: In this prospective study, 240 hemithoraces of 120 consecutive patients with multiple trauma were evaluated with chest radiographs (CXR) and bedside thoracic US for the diagnosis of pneumothorax. CT examinations were performed in 68 patients. Fifty-two patients who did not undergo CT examinations were excluded from the study. US examinations were performed independently at bedside by two radiologists who were not informed about CXR and CT findings. CXRs were interpreted by two radiologists who were unaware of the US and CT results. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of CXR and US were calculated. RESULTS.: One hundred thirty-six hemithoraces were assessed in 68 patients. A total of 35 pneumothoraces were detected in 33 patients. On US, the diagnosis of pneumothorax was correct in 32 hemithoraces. In 98 hemithoraces without pneumothorax, US was normal. With US examination, there were three false-positive and three false-negative results. The sensitivity, specificity, positive predictive value, negative predictive value, and overall accuracy of US were 91.4%, 97%, 91.4%, 97%, and 97%, respectively. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of CXR were 82.7%, 89.7%, 68.5%, 95%, and 89.5%, respectively. CONCLUSIONS.: Bedside thoracic US is an accurate method that can be used in trauma patients instead of CXR for the detection of pneumothorax. Copyright © 2012 Wiley Periodicals, Inc.

  20. Dynamic Contrast-Enhanced Magnetic Resonance Imaging (DCE-MRI) Combined with Positron Emission Tomography-Computed Tomography (PET-CT) and Video-Electroencephalography (VEEG) Have Excellent Diagnostic Value in Preoperative Localization of Epileptic Foci in Children with Epilepsy.

    PubMed

    Wang, Gui-Bin; Long, Wei; Li, Xiao-Dong; Xu, Guang-Yin; Lu, Ji-Xiang

    2017-01-01

    BACKGROUND To investigate the effect that dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) has on surgical decision making relative to video-electroencephalography (VEEG) and positron emission tomography-computed tomography (PET-CT), and if the differences in these variables translates to differences in surgical outcomes. MATERIAL AND METHODS A total of 166 children with epilepsy undergoing preoperative DCE-MRI, VEEG, and PET-CT examinations, surgical resection of epileptic foci, and intraoperative electrocorticography (ECoG) monitoring were enrolled. All children were followed up for 12 months and grouped by Engles prognostic classification for epilepsy. Based on intraoperative ECoG as gold standard, the diagnostic values of DCE-MRI, VEEG, PET-CT, DCE-MRI combined with VEEG, DCE-MRI combined with PET-CT, and combined application of DCE-MRI, VEEG, and PET-CT in preoperative localization for epileptic foci were evaluated. RESULTS The sensitivity of DCE-MRI, VEEG, and PET-CT was 59.64%, 76.51%, and 93.98%, respectively; the accuracy of DCE-MRI, VEEG, PET-CT, DCE-MRI combined with VEEG, and DCE-MRI combined with PET-CT was 57.58%, 67.72%, 91.03%, 91.23%, and 96.49%, respectively. Localization accuracy rate of the combination of DCE-MRI, VEEG, and PET-CT was 98.25% (56/57), which was higher than that of DCE-MRI combined with VEEG and of DCE-MRI combined with PET-CT. No statistical difference was found in the accuracy rate of localization between these three combined techniques. During the 12-month follow-up, children were grouped into Engles grade I (n=106), II (n=31), III (n=21), and IV (n=8) according to postoperative conditions. CONCLUSIONS All DCE-MRI combined with VEEG, DCE-MRI combined with PET-CT, and DCE-MRI combined with VEEG and PET-CT examinations have excellent accuracy in preoperative localization of epileptic foci and present excellent postoperative efficiency, suggesting that these combined imaging methods are suitable for serving as the reference basis in preoperative localization of epileptic foci in children with epilepsy.

  1. Enhancing 18F-FDG-PET/CT analysis in lung cancer patients. Is CT-CT image fusion helpful in predicting pleural involvement? A pilot study.

    PubMed

    Kapfhammer, A; Winkens, T; Lesser, T; Reissig, A; Steinert, M; Freesmeyer, M

    2015-01-01

    To retrospectively evaluate the feasibility and value of CT-CT image fusion to assess the shift of peripheral lung cancers with/-out chest wall infiltration, comparing computed tomography acquisitions in shallow-breathing (SB-CT) and deep-inspiration breath-hold (DIBH-CT) in patients undergoing FDG-PET/CT for lung cancer staging. Image fusion of SB-CT and DIBH-CT was performed with a multimodal workstation used for nuclear medicine fusion imaging. The distance of intrathoracic landmarks and the positional shift of tumours were measured using semi-transparent overlay of both CT series. Statistical analyses were adjusted for confounders of tumour infiltration. Cutoff levels were calculated for prediction of no-/infiltration. Lateral pleural recessus and diaphragm showed the largest respiratory excursions. Infiltrating lung cancers showed more limited respiratory shifts than non-infiltrating tumours. A large respiratory tumour-motility accurately predicted non-infiltration. However, the tumour shifts were limited and variable, limiting the accuracy of prediction. This pilot fusion study proved feasible and allowed a simple analysis of the respiratory shifts of peripheral lung tumours using CT-CT image fusion in a PET/CT setting. The calculated cutoffs were useful in predicting the exclusion of chest wall infiltration but did not accurately predict tumour infiltration. This method can provide additional qualitative information in patients with lung cancers with contact to the chest wall but unclear CT evidence of infiltration undergoing PET/CT without the need of additional investigations. Considering the small sample size investigated, further studies are necessary to verify the obtained results.

  2. [A Case of Surgery after Chemotherapy for Cecal Cancer with Onset of the Stenosis of the Colostomy].

    PubMed

    Kono, Teppei; Yokomizo, Hajime; Yano, Yuki; Okayama, Sachiyo; Satake, Masaya; Yamada, Yasufumi; Ida, Arika; Usui, Takebumi; Yamaguchi, Kentaro; Shiozawa, Shunichi; Yoshimatsu, Kazuhiko; Shimakawa, Takeshi; Katsube, Takao; Kato, Hiroyuki; Naritaka, Yoshihiko

    2018-02-01

    The patient was 55-year-old woman, undergoing Hartmann operation by the sigmoid colon diverticulum perforation, 2 years later visited our hospital with abdominal pain. Although lower endoscopy and histological examination could not be performed due to stoma stenosis, we diagnosed cecal carcinoma, liver metastasis, distant lymph node metastasis from CT and PET-CT, CapeOX plus Bmabtherapy and IRIS plus Bmabtherapy were performed. After that, repeated intestinal obstruction due to exacerbated stoma stenosis, metastatic lesion increased in CT examination, furthermore the patient had hope of stoma closure, we decided to resect the primacy tumor, performed subtotal colonectomy and stoma closure. Pathological diagnosis revealed RAS wild type. After surgery, Pmabplus CPT-11 therapy was performed and the metastatic lesion was temporarily shrunk but re-exacerbated, the patient died 2 years 2 months after the first treatment started, 7 months after the primary tumor resection. In the treatment of colorectal cancer, when metastatic lesion is unresectable, chemotherapy is often carried out except when the primary tumor is symptomatic. In our case, although the primary tumor was asymptomatic, an intestinal obstruction due to stoma stenosis was developed and it was necessary to examine whether to use anti-EGFR antibody drugs, therefore we performed operation.

  3. Precision phenotyping, panomics, and system-level bioinformatics to delineate complex biologies of atherosclerosis: rationale and design of the "Genetic Loci and the Burden of Atherosclerotic Lesions" study.

    PubMed

    Voros, Szilard; Maurovich-Horvat, Pal; Marvasty, Idean B; Bansal, Aruna T; Barnes, Michael R; Vazquez, Gustavo; Murray, Sarah S; Voros, Viktor; Merkely, Bela; Brown, Bradley O; Warnick, G Russell

    2014-01-01

    Complex biological networks of atherosclerosis are largely unknown. The main objective of the Genetic Loci and the Burden of Atherosclerotic Lesions study is to assemble comprehensive biological networks of atherosclerosis using advanced cardiovascular imaging for phenotyping, a panomic approach to identify underlying genomic, proteomic, metabolomic, and lipidomic underpinnings, analyzed by systems biology-driven bioinformatics. By design, this is a hypothesis-free unbiased discovery study collecting a large number of biologically related factors to examine biological associations between genomic, proteomic, metabolomic, lipidomic, and phenotypic factors of atherosclerosis. The Genetic Loci and the Burden of Atherosclerotic Lesions study (NCT01738828) is a prospective, multicenter, international observational study of atherosclerotic coronary artery disease. Approximately 7500 patients are enrolled and undergo non-contrast-enhanced coronary calcium scanning by CT for the detection and quantification of coronary artery calcium, as well as coronary artery CT angiography for the detection and quantification of plaque, stenosis, and overall coronary artery disease burden. In addition, patients undergo whole genome sequencing, DNA methylation, whole blood-based transcriptome sequencing, unbiased proteomics based on mass spectrometry, as well as metabolomics and lipidomics on a mass spectrometry platform. The study is analyzed in 3 subsequent phases, and each phase consists of a discovery cohort and an independent validation cohort. For the primary analysis, the primary phenotype will be the presence of any atherosclerotic plaque, as detected by cardiac CT. Additional phenotypic analyses will include per patient maximal luminal stenosis defined as 50% and 70% diameter stenosis. Single-omic and multi-omic associations will be examined for each phenotype; putative biomarkers will be assessed for association, calibration, discrimination, and reclassification. Copyright © 2014 The Authors. Published by Elsevier Inc. All rights reserved.

  4. Estimation of radiation dose to patients from (18) FDG whole body PET/CT investigations using dynamic PET scan protocol.

    PubMed

    Kaushik, Aruna; Jaimini, Abhinav; Tripathi, Madhavi; D'Souza, Maria; Sharma, Rajnish; Mondal, Anupam; Mishra, Anil K; Dwarakanath, Bilikere S

    2015-12-01

    There is a growing concern over the radiation exposure of patients from undergoing 18FDG PET/CT (18F-fluorodeoxyglucose positron emission tomography/computed tomography) whole body investigations. The aim of the present study was to study the kinetics of 18FDG distributions and estimate the radiation dose received by patients undergoing 18FDG whole body PET/CT investigations. Dynamic PET scans in different regions of the body were performed in 49 patients so as to measure percentage uptake of 18FDG in brain, liver, spleen, adrenals, kidneys and stomach. The residence time in these organs was calculated and radiation dose was estimated using OLINDA software. The radiation dose from the CT component was computed using the software CT-Expo and measured using computed tomography dose index (CTDI) phantom and ionization chamber. As per the clinical protocol, the patients were refrained from eating and drinking for a minimum period of 4 h prior to the study. The estimated residence time in males was 0.196 h (brain), 0.09 h (liver), 0.007 h (spleen), 0.0006 h (adrenals), 0.013 h (kidneys) and 0.005 h (stomach) whereas it was 0.189 h (brain), 0.11 h (liver), 0.01 h (spleen), 0.0007 h (adrenals), 0.02 h (kidneys) and 0.004 h (stomach) in females. The effective dose was found to be 0.020 mSv/MBq in males and 0.025 mSv/MBq in females from internally administered 18FDG and 6.8 mSv in males and 7.9 mSv in females from the CT component. For an administered activity of 370 MBq of 18FDG, the effective dose from PET/CT investigations was estimated to be 14.2 mSv in males and 17.2 mSv in females. The present results did not demonstrate significant difference in the kinetics of 18FDG distribution in male and female patients. The estimated PET/CT doses were found to be higher than many other conventional diagnostic radiology examinations suggesting that all efforts should be made to clinically justify and carefully weigh the risk-benefit ratios prior to every 18FDG whole body PET/CT scan.

  5. Patient experiences of colonoscopy, barium enema and CT colonography: a qualitative study.

    PubMed

    Von Wagner, C; Knight, K; Halligan, S; Atkin, W; Lilford, R; Morton, D; Wardle, J

    2009-01-01

    Previous studies of patient experience with bowel screening tests, in particular CT colonography (CTC), have superimposed global rating scales and not explored individual experience in detail. To redress this, we performed qualitative interviews in order to characterize patient expectations and experiences in depth. Following ethical permission, 16 patients undergoing CTC, 18 undergoing colonoscopy and 15 undergoing barium enema agreed to a semi-structured interview by a health psychologist. Interviews were recorded, responses transcribed and themes extracted with the aim of assimilating individual experiences to facilitate subsequent development and interpretation of quantitative surveys of overall satisfaction with each diagnostic test. Transcript analysis identified three principal themes: physical sensations, social interactions and information provision. Physical sensations differed for each test but were surprisingly well tolerated overall. Social interactions with staff were perceived as very important in colouring the whole experience, particularly in controlling the feelings of embarrassment, which was critical for all procedures. Information provision was also an important determinant of experience. Verbal feedback was most common during colonoscopy and invariably reassuring. However, patients undergoing CTC received little visual or verbal feedback and were often confused regarding the test outcome. Barium enema had no specific advantage over other tests. Qualitative interviews provided important perspectives on patient experience. Our data demonstrated that models describing the quality of medical encounters are applicable to single diagnostic episodes. Staff interactions and information provision were particularly important. We found advantages specific to both CTC and colonoscopy but none for barium enema. CTC could benefit greatly from improved information provision following examination.

  6. MDCT imaging of the stomach: advances and applications

    PubMed Central

    Prakash, Anjali; Pradhan, Gaurav; Vidholia, Aditi; Nagpal, Nishant; Saboo, Sachin S; Kuehn, David M; Khandelwal, Ashish

    2017-01-01

    The stomach may be involved by a myriad of pathologies ranging from benign aetiologies like inflammation to malignant aetiologies like carcinoma or lymphoma. Multidetector CT (MDCT) of the stomach is the first-line imaging for patients with suspected gastric pathologies. Conventionally, CT imaging had the advantage of simultaneous detection of the mural and extramural disease extent, but advances in MDCT have allowed mucosal assessment by virtual endoscopy (VE). Also, better three-dimensional (3D) post-processing techniques have enabled more robust and accurate pre-operative planning in patients undergoing gastrectomy and even predict the response to surgery for patients undergoing laparoscopic sleeve gastrectomy for weight loss. The ability of CT to obtain stomach volume (for bariatric surgery patients) and 3D VE images depends on various patient and protocol factors that are important for a radiologist to understand. We review the appropriate CT imaging protocol in the patients with suspected gastric pathologies and highlight the imaging pearls of various gastric pathologies on CT and VE. PMID:27785936

  7. MDCT imaging of the stomach: advances and applications.

    PubMed

    Nagpal, Prashant; Prakash, Anjali; Pradhan, Gaurav; Vidholia, Aditi; Nagpal, Nishant; Saboo, Sachin S; Kuehn, David M; Khandelwal, Ashish

    2017-01-01

    The stomach may be involved by a myriad of pathologies ranging from benign aetiologies like inflammation to malignant aetiologies like carcinoma or lymphoma. Multidetector CT (MDCT) of the stomach is the first-line imaging for patients with suspected gastric pathologies. Conventionally, CT imaging had the advantage of simultaneous detection of the mural and extramural disease extent, but advances in MDCT have allowed mucosal assessment by virtual endoscopy (VE). Also, better three-dimensional (3D) post-processing techniques have enabled more robust and accurate pre-operative planning in patients undergoing gastrectomy and even predict the response to surgery for patients undergoing laparoscopic sleeve gastrectomy for weight loss. The ability of CT to obtain stomach volume (for bariatric surgery patients) and 3D VE images depends on various patient and protocol factors that are important for a radiologist to understand. We review the appropriate CT imaging protocol in the patients with suspected gastric pathologies and highlight the imaging pearls of various gastric pathologies on CT and VE.

  8. Reduced dose CT with model-based iterative reconstruction compared to standard dose CT of the chest, abdomen, and pelvis in oncology patients: intra-individual comparison study on image quality and lesion conspicuity.

    PubMed

    Morimoto, Linda Nayeli; Kamaya, Aya; Boulay-Coletta, Isabelle; Fleischmann, Dominik; Molvin, Lior; Tian, Lu; Fisher, George; Wang, Jia; Willmann, Jürgen K

    2017-09-01

    To compare image quality and lesion conspicuity of reduced dose (RD) CT with model-based iterative reconstruction (MBIR) compared to standard dose (SD) CT in patients undergoing oncological follow-up imaging. Forty-four cancer patients who had a staging SD CT within 12 months were prospectively included to undergo a weight-based RD CT with MBIR. Radiation dose was recorded and tissue attenuation and image noise of four tissue types were measured. Reproducibility of target lesion size measurements of up to 5 target lesions per patient were analyzed. Subjective image quality was evaluated for three readers independently utilizing 4- or 5-point Likert scales. Median radiation dose reduction was 46% using RD CT (P < 0.01). Median image noise across all measured tissue types was lower (P < 0.01) in RD CT. Subjective image quality for RD CT was higher (P < 0.01) in regard to image noise and overall image quality; however, there was no statistically significant difference regarding image sharpness (P = 0.59). There were subjectively more artifacts on RD CT (P < 0.01). Lesion conspicuity was subjectively better in RD CT (P < 0.01). Repeated target lesion size measurements were highly reproducible both on SD CT (ICC = 0.987) and RD CT (ICC = 0.97). RD CT imaging with MBIR provides diagnostic imaging quality and comparable lesion conspicuity on follow-up exams while allowing dose reduction by a median of 46% compared to SD CT imaging.

  9. WebCT: A Major Shift of Emphasis

    ERIC Educational Resources Information Center

    Morningstar, Barbara; Schubert, Jeremy; Thibeault, Kristine

    2004-01-01

    The evaluation reports in this series usually feature several products at once. The current review, however, comes at a time when one of the most widely used (and expensive) online learning management systems is undergoing a major change in its marketing strategy and corporate focus. "WebCT" is currently evolving to a new version ("WebCT Vista"),…

  10. Predicting Infected Bile Among Patients Undergoing Percutaneous Cholecystostomy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Beardsley, Shannon L.; Shlansky-Goldberg, Richard D.; Patel, Aalpen

    2005-04-15

    Purpose. Patients may not achieve a clinical benefit after percutaneous cholecystostomy due to the inherent difficulty in identifying patients who truly have infected gallbladders. We attempted to identify imaging and biochemical parameters which would help to predict which patients have infected gallbladders. Methods. A retrospective review was performed of 52 patients undergoing percutaneous cholecystostomy for clinical suspicion of acute cholecystitis in whom bile culture results were available. Multiple imaging and biochemical variables were examined alone and in combination as predictors of infected bile, using logistic regression. Results. Of the 52 patients, 25 (48%) had infected bile. Organisms cultured included Enterococcus,more » Enterobacter, Klebsiella, Pseudomonas, E. coli, Citrobacter and Candida. No biochemical parameters were significantly predictive of infected bile; white blood cell count >15,000 was weakly associated with greater odds of infected bile (odds ratio 2.0, p = NS). The presence of gallstones, sludge, gallbladder wall thickening and pericholecystic fluid by ultrasound or CT were not predictive of infected bile, alone or in combination, although a trend was observed among patients with CT findings of acute cholecystitis toward a higher 30-day mortality. Radionuclide scans were performed in 31% of patients; all were positive and 66% of these patients had infected bile. Since no patient who underwent a radionuclide scan had a negative study, this variable could not be entered into the regression model due to collinearity. Conclusion. No single CT or ultrasound imaging variable was predictive of infected bile, and only a weak association of white blood cell count with infected bile was seen. No other biochemical parameters had any association with infected bile. The ability of radionuclide scanning to predict infected bile was higher than that of ultrasound or CT. This study illustrates the continued challenge to identify bacterial cholecystitis among patients referred for percutaneous cholecystostomy.« less

  11. Criteria for Performing Cranial Computed Tomography for Chinese Patients With Mild Traumatic Brain Injury: Canadian Computed Tomography Head Rule or New Orleans Criteria?

    PubMed

    Yang, Xiao-Feng; Meng, Yuan-Yuan; Wen, Liang; Wang, Hao

    2017-09-01

    Computed tomography (CT) provides the primary diagnostic evidence for traumatic brain injury (TBI), but few positive traumatic findings are discovered in patients with mild TBI. In China, there are no existing criteria for selecting patients with mild TBI to undergo CT, and almost all of these patients undergo cranial CT in the emergency department. This retrospective study was performed to evaluate the necessity of cranial CT among patients with mild TBI, as well as the feasibility of 2 popular criteria (Canadian CT head rule [CCHR] and New Orleans Criteria [NOC]) in China. Patients with mild TBI who underwent cranial CT within 24 hours of the trauma were included in our institute. Two neurosurgeons reviewed the CT images independently to identify positive CT findings. The sensitivity and specificity of CCHR and NOC for positive CT findings related to TBI were analyzed. Finally, this study included 625 patients. Positive CT findings related to TBI were discovered in 13.12% (82/625) of these patients on cranial CT, and 6.88% (43/625) of them were admitted to the hospital for further management. Ultimately, 11 patients (1.76%, 11/625) underwent neurosurgery. In this study, the sensitivities of both the CCHR and NOC were 100%, but the specificity of CCHR was 43.36% and that of NOC was 33.12%. Based on our study, both CCHR and NOC have high sensitivity for the detection of positive CT findings related to head trauma in patients with mild TBI.

  12. Degree of Biomimicry of Artificial Spider Silk Spinning Assessed by NMR Spectroscopy.

    PubMed

    Otikovs, Martins; Andersson, Marlene; Jia, Qiupin; Nordling, Kerstin; Meng, Qing; Andreas, Loren B; Pintacuda, Guido; Johansson, Jan; Rising, Anna; Jaudzems, Kristaps

    2017-10-02

    Biomimetic spinning of artificial spider silk requires that the terminal domains of designed minispidroins undergo specific structural changes in concert with the β-sheet conversion of the repetitive region. Herein, we combine solution and solid-state NMR methods to probe domain-specific structural changes in the NT2RepCT minispidroin, which allows us to assess the degree of biomimicry of artificial silk spinning. In addition, we show that the structural effects of post-spinning procedures can be examined. By studying the impact of NT2RepCT fiber drying, we observed a reversible beta-to-alpha conversion. We think that this approach will be useful for guiding the optimization of artificial spider silk fibers. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Assessing stapes piston position using computed tomography: a cadaveric study.

    PubMed

    Hahn, Yoav; Diaz, Rodney; Hartman, Jonathan; Bobinski, Matthew; Brodie, Hilary

    2009-02-01

    Temporal bone computed tomographic (CT) scanning in the postoperative stapedotomy patient is inaccurate in assessing stapes piston position within the vestibule. Poststapedotomy patients that have persistent vertigo may undergo CT scanning to assess the position of the stapes piston within the vestibule to rule out overly deep insertion. Vertigo is a recognized complication of the deep piston, and CT evaluation is often recommended. The accuracy of CT scan in this setting is unestablished. Stapedotomy was performed on 12 cadaver ears, and stainless steel McGee pistons were placed. The cadaver heads were then scanned using a fine-cut temporal bone protocol. Temporal bone dissection was performed with microscopic measurement of the piston depth in the vestibule. These values were compared with depth of intravestibular penetration measured on CT scan by 4 independent measurements. The intravestibular penetration as assessed by computed tomography was consistently greater than the value found on cadaveric anatomic dissection. The radiographic bias was greater when piston location within the vestibule was shallower. The axial CT scan measurement was 0.53 mm greater, on average, than the anatomic measurement. On average, the coronal CT measurement was 0.68 mm greater than the anatomic measurement. The degree of overestimation of penetration, however, was highly inconsistent. Standard temporal bone CT scan is neither an accurate nor precise examination of stapes piston depth within the vestibule. We found that CT measurement consistently overstated intravestibular piston depth. Computed tomography is not a useful study in the evaluation of piston depth for poststapedectomy vertigo and is of limited value in this setting.

  14. Relative hypotension increases the probability of the need for angioembolisation in pelvic fracture patients without contrast extravasation on computed tomography scan.

    PubMed

    Kuo, Ling-Wei; Yang, Shang-Ju; Fu, Chih-Yuan; Liao, Chien-Hung; Wang, Shang-Yu; Wu, Shih-Chi

    2016-01-01

    In the evaluation of haemorrhage in trauma patients with pelvic fractures, contrast extravasation (CE) on computed tomography (CT) scan often implies active arterial bleeding. However, the absence of CE on CT scan does not always exclude the need for transcatheter arterial embolisation (TAE) to achieve haemostasis. In the current study, we evaluated the factors associated with the need for TAE in patients without CE on CT scan. These factors may be evaluated as adjuncts to CT scanning in the management of patients with pelvic fractures. We retrospectively reviewed our trauma registry and medical records of patients with pelvic fractures. When CE was observed, indicating active haemorrhage, the patients underwent TAE to achieve haemostasis. In contrast, patients without CE were held for observation and treatment of their injuries, and if their condition deteriorated after a delayed interval, they were then also referred for TAE if no other focus of haemorrhage was found. Patients without CE on CT scan but with retroperitoneal haemorrhage requiring TAE were investigated. Their demographic characteristics, associated injuries, fracture patterns, and changes in systolic blood pressure were described and analysed. In total, 201 patients with pelvic fracture underwent CT scan examination; 47 (23.4%) had CE by CT scan, whereas the other 154 (76.6%) did not. Of the 154 patients who did not show CE by CT scan, 124 (80.5%) patients never underwent TAE; however, 30 (19.5%) of these patients did eventually undergo TAE. In comparing the patients who underwent TAE to those who did not undergo TAE among patients without CE on CT scan, the systolic blood pressure (SBP) on arrival (median: 100.0 mmHg vs 136.0 mmHg, p<0.01) and the lowest SBP recorded in the ED (median: 68.0 mmHg vs 129.0 mmHg, p<0.01) were significantly lower in the patients who underwent TAE. The ROC curve analysis revealed that the most appropriate cutoff value of decrement of SBP (SBP on arrival minus the lowest SBP in the ED) was 30 mmHg (AUC=0.89). In the management of pelvic fracture patients, greater attention should be directed toward patients with relative hypotension. The higher likelihood of haemodynamic deterioration and the need for TAE for haemorrhage control should remain under consideration in such cases, despite the absence of CE by CT scan. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Primary Intimal Sarcoma of Thoracic Aorta Presenting as Hypertensive Crisis

    PubMed Central

    Lin, Shu-I; Su, Min-I; Tsai, Cheng-Ting

    2015-01-01

    We report a 45-year-old woman who presented to our facility in a hypertensive crisis. Computed tomography (CT) revealed a thoracic aortic tumor, and tissues obtained via endovascular biopsy revealed undifferentiated sarcoma. A final diagnosis of intimal sarcoma was made by intra-operative pathological examination. Despite undergoing surgical resection followed by adjuvant chemotherapy, the patient died from progressive multiple metastasis and severe sepsis. Although aortic sarcoma is rarely diagnosed, it should be considered a possible etiology of hypertensive crisis. PMID:27122923

  16. Is gender still a predisposing factor in contrast-media associated adverse drug reactions? A systematic review and meta-analysis of randomized trials and observational studies.

    PubMed

    Lee, Heeyoung; Song, Seungyeon; Oh, Yun-Kyoung; Kang, WonKu; Kim, Eunyoung

    2017-04-01

    To evaluate the role of gender as a risk factor for developing contrast media-associated adverse drug reactions (CM-ADRs) by comparing the incidence of CM-ADR between male and female patients according to study design, ADR type, and computed tomography (CT) examination. We systematically searched three electronic databases for eligible studies. In the studies included (n=18), we assessed effect estimates of the relative incidence of CM-ADR, analysed by experimental design, ADR type and CT examination. This was calculated by using a random effects model if clinical conditions showed heterogeneity; otherwise, a fixed effects model was used. We identified 10,776 patients administered CM. According to the designs, studies were classified into randomised controlled trials (RCTs) and observational studies. Results were as follows: risk ratio (RR)=1.07 (95% confidence interval (CI): 0.79-1.46, P=0.66) for RCTs, and RR=0.77 (95% CI: 0.58-1.04, P=0.09) for observational studies. The results of analysis according to ADR type and for undergoing CT demonstrated that the incidence of CM-ADR did not differ between males and females. We found no significant difference in the incidence of CM-ADRs between male and female patients according to study design, ADR type, or CT examination. Future studies to determine why gender has shown different roles as a risk factor between CM-ADRs and non-CM ADRs are needed. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Crohn's Disease

    MedlinePlus

    ... causes, such as infection. You may also undergo flexible sigmoidoscopy, colonoscopy, body CT, body MRI, MR enterography, upper GI, small ... Flexible sigmoidoscopy , performed by inserting a sigmoidoscope (a flexible tube ... can also sometimes be seen. Body CT scan , a special type of x-ray ...

  18. Targeted delayed scanning at CT urography: a worthwhile use of radiation?

    PubMed

    Hack, Kalesha; Pinto, Patricia A; Gollub, Marc J

    2012-10-01

    To determine whether ureteral segments not filled with contrast material at computed tomographic (CT) urography ever contain tumor detectable only by filling these segments with contrast material. In this institutional review board-approved, HIPAA-compliant retrospective study, with waiver of informed consent, databases were searched for all patients who underwent heminephroureterectomy or ureteroscopy between January 1, 2001, and December 31, 2009, with available CT urography findings in the 12 months prior to surgery or biopsy and patients who had undergone at least two CT urography procedures with a minimum 5-year follow-up between studies. One of two radiologists blinded to results of pathologic examination recorded location of unfilled segments, time of scan, subsequent filling, and pathologic or 5-year follow-up CT urography results. Tumors were considered missed in an unfilled segment if tumor was found at pathologic examination or follow-up CT urography in the same one-third of the ureter and there were no secondary signs of a mass with other index CT urography sequences. Estimated radiation dose for additional delayed sequences was calculated with a 32-cm phantom. In 59 male and 33 female patients (mean age, 66 years) undergoing heminephroureterectomy, 27 tumors were present in 41 partially nonopacified ureters in 20 patients. Six tumors were present in nonopacified segments (one multifocal, none bilateral); all were identifiable by means of secondary signs present with earlier sequences. Among 182 lesions biopsied at ureteroscopy in 124 male and 53 female patients (mean age, 69 years), 28 tumors were present in nonopacified segments in 25 patients (four multifocal, none bilateral), all with secondary imaging signs detectable without delayed scanning. In 64 male and 29 female patients (mean age, 69 years) who underwent 5-year follow-up CT urography, three new tumors were revealed in three patients; none occurred in the unfilled ureter at index CT urography. Estimated radiation dose from additional sequences was 4.3 mSv per patient. Targeted delayed scanning at CT urography yielded no additional ureteral tumors and resulted in additional radiation exposure. © RSNA, 2012.

  19. Bladder cancer diagnosis with CT urography: test characteristics and reasons for false-positive and false-negative results.

    PubMed

    Trinh, Tony W; Glazer, Daniel I; Sadow, Cheryl A; Sahni, V Anik; Geller, Nina L; Silverman, Stuart G

    2018-03-01

    To determine test characteristics of CT urography for detecting bladder cancer in patients with hematuria and those undergoing surveillance, and to analyze reasons for false-positive and false-negative results. A HIPAA-compliant, IRB-approved retrospective review of reports from 1623 CT urograms between 10/2010 and 12/31/2013 was performed. 710 examinations for hematuria or bladder cancer history were compared to cystoscopy performed within 6 months. Reference standard was surgical pathology or 1-year minimum clinical follow-up. False-positive and false-negative examinations were reviewed to determine reasons for errors. Ninety-five bladder cancers were detected. CT urography accuracy: was 91.5% (650/710), sensitivity 86.3% (82/95), specificity 92.4% (568/615), positive predictive value 63.6% (82/129), and negative predictive value was 97.8% (568/581). Of 43 false positives, the majority of interpretation errors were due to benign prostatic hyperplasia (n = 12), trabeculated bladder (n = 9), and treatment changes (n = 8). Other causes include blood clots, mistaken normal anatomy, infectious/inflammatory changes, or had no cystoscopic correlate. Of 13 false negatives, 11 were due to technique, one to a large urinary residual, one to artifact. There were no errors in perception. CT urography is an accurate test for diagnosing bladder cancer; however, in protocols relying predominantly on excretory phase images, overall sensitivity remains insufficient to obviate cystoscopy. Awareness of bladder cancer mimics may reduce false-positive results. Improvements in CTU technique may reduce false-negative results.

  20. Locoregional outcomes in clinical stage IIB breast cancer after neoadjuvant therapy and mastectomy with or without radiation.

    PubMed

    Diaz, Dayssy A; Hurley, Judith; Reis, Isildinha; Takita, Cristiane; Zhao, Wei; Wright, Jean

    2014-12-01

    Low rates of locoregional recurrence (LRR) in patients with clinical stage IIB breast cancer (cT2N1 or cT3N0) who undergo neoadjuvant therapy (NAT) and mastectomy have been reported. We aimed to quantify the risk of LRR and the relationship between LRR and potential risk factors in this subset of patients. We conducted a retrospective review of 116 patients with clinical IIB breast cancer who underwent NAT followed by mastectomy +/- postmastectomy radiotherapy (PMRT) between 2000 and 2009. We estimated the rate of LRR by cumulative incidence. The effect of prognostic factors was examined by Gray's test and Fine and Gray's test. Median follow-up: 63 months. Median age: 49. 28.4% cT2N1 and 71.6% cT3N0. 62.1% of tumors were ER+, 22.6% HER2+, 19% triple negative (TN). All patients underwent NAT and mastectomy. The majority of patients (87%) received PMRT; 32.3% were treated to chest wall (CW) only, and 67.7% to CW plus supraclavicular (SCV) field. Compared to cT2N1, patients with cT3N0 disease were more likely to be pN0 (60% vs 27%, P = 0.005). There was no significant relationship between risk of LRR and pathologic complete response (pCR), use of PMRT, RT to SCV field, or TN status, but there was higher risk of LRR in cT2N1 than cT3N0 (HR 6.03, P = 0.015). LRR was more common in cT2N1 than in cT3N0 disease, emphasizing the negative prognostic implication of clinically node-positive presentation.

  1. Real-life Experience for Integration of PET-CT in the Treatment of Hodgkin Lymphoma in Lebanon.

    PubMed

    Sakr, Riwa; Massoud, Marcel; Kerbage, Fouad; Rached, Layale; Zeghondy, Jean; Akoury, Elie; Nasr, Fady; Chahine, Georges

    2017-07-01

    Hodgkin lymphoma (HL) is a highly curable disease; < 80% of patients will achieve long-term survival. Positron emission tomography-computed tomography (PET-CT) has played a major role in the evaluation of both disease staging and response and has become an essential component in tailoring patients' treatment. We report the effect of integrating PET-CT into the management of HL in Lebanon. We analyzed the data regarding the usage of PET-CT at diagnosis, during treatment (interim PET), and at the end of treatment. We also analyzed the PET-CT findings from 2009 to 2015. The first PET-CT system was introduced in Lebanon in April 2002 but was not used for the evaluation of HL. Early in 2009, we started to incorporate PET-CT into the treatment of HL. By the end of 2009, 70% of patients were undergoing PET-CT at diagnosis and at the end of treatment. This proportion remained constant until 2013, when an increase occurred, with ≤ 94% of patients undergoing PET-CT at diagnosis. The usage of CT at diagnosis decreased significantly from 70% before 2009 to 52% after 2015. In contrast, CT usage at the end of treatment has fluctuated from 10% in 2009 to 0% in 2012, 2013, and 2014 and 11.76% in 2015. Functional imaging techniques are increasing in popularity compared with anatomic imaging. The usage of PET-CT has emerged as a highly valuable staging and follow-up method in the treatment of HL 8 years after the introduction of PET in Lebanon. PET was used first to improve the staging, then to evaluate the treatment response, and, recently, to tailor therapy according to the response. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Development Of A Flash X-Ray Scanner For Stereoradiography And CT

    NASA Astrophysics Data System (ADS)

    Endorf, Robert J.; DiBianca, Frank A.; Fritsch, Daniel S.; Liu, Wen-Ching; Burns, Charles B.

    1989-05-01

    We are developing a flash x-ray scanner for stereoradiography and CT which will be able to produce a stereoradiograph in 30 to 70 ns and a complete CT scan in one microsecond. This type of imaging device will be valuable in studying high speed processes, high acceleration, and traumatic events. We have built a two channel flash x-ray system capable of producing stereo radiographs with stereo angles of from 15 to 165 degrees. The dynamic and static Miff 's for the flash x-ray system were measured and compared with similar MIT's measured for a conventional medical x-ray system. We have written and tested a stereo reconstruction algorithm to determine three dimensional space points from corresponding points in the two stereo images. To demonstrate the ability of the system to image traumatic events, a radiograph was obtained of a bone undergoing a fracture. The effects of accelerations of up to 600 g were examined on radiographs taken of human kidney tissue samples in a rapidly rotating centrifuge. Feasibility studies of CT reconstruction have been performed by making simulated Cr images of various phantoms for larger flash x-ray systems of from 8 to 29 flash x-ray tubes.

  3. A randomized comparison of 1-h sodium bicarbonate hydration versus standard peri-procedural saline hydration in patients with chronic kidney disease undergoing intravenous contrast-enhanced computerized tomography.

    PubMed

    Kooiman, Judith; Sijpkens, Yvo W J; de Vries, Jean-Paul P M; Brulez, Harald F H; Hamming, Jaap F; van der Molen, Aart J; Aarts, Nico J M; Cannegieter, Suzanne C; Putter, Hein; Swarts, Renate; van den Hout, Wilbert B; Rabelink, Ton J; Huisman, Menno V

    2014-05-01

    Guidelines recommend saline hydration for prophylaxis of contrast-induced acute kidney injury (CI-AKI) in patients with chronic kidney disease (CKD) undergoing intravenous contrast media-enhanced CT (CE-CT). The safety and efficacy of a brief hydration protocol using sodium bicarbonate in this population is unknown. We analysed whether 1-h sodium bicarbonate hydration prior to CE-CT is non-inferior to saline hydration prior to and after CE-CT in CKD patients. We performed an open-label multicentre randomized trial. Patients were randomized to 250 mL of 1.4% sodium bicarbonate hydration prior to CE-CT or 1000 mL of 0.9% saline hydration prior to and, once again, after CE-CT. Primary outcome was the relative increase in serum creatinine 48-96 h post-CE-CT. Secondary outcomes were incidence of CI-AKI [serum creatinine increase >25%/>44 µmol/L (0.5 mg/dL)], recovery of renal function, the need for dialysis and 2-month hospital costs. Five hundred and seventy adult CKD patients undergoing CE-CT were randomized between 2010 and 2012, of whom 548 were included in the intention-to-treat population. Mean relative serum creatinine increase was 1.2% for sodium bicarbonate and 1.5% for saline (mean difference -0.3%; 95% confidence interval -2.7 to 2.1, P-value for non-inferiority <0.0001). CI-AKI occurred in 22 patients (4.1%); 8 (3.0%) randomized to sodium bicarbonate versus 14 (5.1%) to saline (P = 0.23). Renal function recovered in 75 and 69% of CI-AKI patients, respectively (P = 0.81). No patients developed a need for dialysis. Mean hydration costs per patient were €224 for the sodium bicarbonate and €683 for the saline regime (P < 0.001). Other healthcare costs were similar. Short hydration with sodium bicarbonate prior to CE-CT was non-inferior to peri-procedural saline hydration with respect to renal safety and may result in healthcare savings. [Netherlands Trial Register (http://www.trialregister.nl/trialreg/index.asp), Nr 2149, date of registration 23 December 2009.].

  4. Lymphoma and tuberculosis: temporal evolution of dual pathology on sequential 18F-FDG PET/CT.

    PubMed

    Mukherjee, Anirban; Sharma, Punit; Karunanithi, Sellam; Dhull, Varun Singh; Kumar, Rakesh

    2014-08-01

    Tuberculosis can often be seen in patients undergoing chemotherapy for lymphoma, especially in endemic countries. As both tuberculosis and lymphoma can lead to hypermetabolic lesions of F-FDG PET/CT, a diagnostic dilemma often ensues. We present the sequential F-FDG PET/CT images of a 22-year-old female patient with Hodgkin lymphoma who developed tuberculosis and later relapse of lymphoma. These images present the temporal evaluation of the dual pathology on F-FDG PET/CT.

  5. Using injectable hydrogel markers to assess resimulation for boost target volume definition in a patient undergoing whole-breast radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Patel, Henal; Goyal, Sharad; Kim, Leonard, E-mail: kimlh@rutgers.edu

    Several publications have recommended that patients undergoing whole-breast radiotherapy be resimulated for boost planning. The rationale for this is that the seroma may be smaller when compared with the initial simulation. However, the decision remains whether to use the earlier or later images to define an appropriate boost target volume. A patient undergoing whole-breast radiotherapy had new, injectable, temporary hydrogel fiducial markers placed 1 to 3 cm from the seroma at the time of initial simulation. The patient was resimulated 4.5 weeks later for conformal photon boost planning. Computed tomography (CT) scans acquired at the beginning and the end ofmore » whole-breast radiotherapy showed that shrinkage of the lumpectomy cavity was not matched by a corresponding reduction in the surrounding tissue volume, as demarcated by hydrogel markers. This observation called into question the usual interpretation of cavity shrinkage for boost target definition. For this patient, it was decided to define the boost target volume on the initial planning CT instead of the new CT.« less

  6. Detection of incidental cardiac findings in noncardiac chest computed tomography

    PubMed Central

    Secchi, Francesco; Di Leo, Giovanni; Zanardo, Moreno; Alì, Marco; Cannaò, Paola Maria; Sardanelli, Francesco

    2017-01-01

    Abstract The aim of the study was to estimate the rate of incidental cardiac findings (ICF) in patients undergoing noncardiac chest CT. An experienced radiologist retrospectively reviewed 237 consecutive patients (147 males and 90 females with median age of 69 years) undergoing a noncardiac chest CT. ICF at targeted review were compared to those mentioned in original reports (χ2 test). At review, ≥1 ICF was detected in 124/237 patients (52%), for a total of 229 ICF, 158 of them (69%) not originally mentioned. Valvular calcifications were unmentioned in 23/23 (100%) patients, main pulmonary artery dilation in 21/22 (96%), coronary calcifications in 69/86 (80%), right or left atrial dilation in 7/11 (64%), aortic atherosclerosis in 29/62 (47%), and ascending aorta dilatation in 8/18 (44%). All 6 pericardial effusions were originally mentioned. No association with sex (P ≥ .189); positive correlation with age (P < .001). Half of patients undergoing noncardiac chest CT presented ≥1 ICF, independently from sex but increasing with age. Moreover, 69% of detectable ICFs were not originally mentioned. PMID:28723768

  7. Detection of incidental cardiac findings in noncardiac chest computed tomography.

    PubMed

    Secchi, Francesco; Di Leo, Giovanni; Zanardo, Moreno; Alì, Marco; Cannaò, Paola Maria; Sardanelli, Francesco

    2017-07-01

    The aim of the study was to estimate the rate of incidental cardiac findings (ICF) in patients undergoing noncardiac chest CT.An experienced radiologist retrospectively reviewed 237 consecutive patients (147 males and 90 females with median age of 69 years) undergoing a noncardiac chest CT. ICF at targeted review were compared to those mentioned in original reports (χ test).At review, ≥1 ICF was detected in 124/237 patients (52%), for a total of 229 ICF, 158 of them (69%) not originally mentioned. Valvular calcifications were unmentioned in 23/23 (100%) patients, main pulmonary artery dilation in 21/22 (96%), coronary calcifications in 69/86 (80%), right or left atrial dilation in 7/11 (64%), aortic atherosclerosis in 29/62 (47%), and ascending aorta dilatation in 8/18 (44%). All 6 pericardial effusions were originally mentioned. No association with sex (P ≥ .189); positive correlation with age (P < .001).Half of patients undergoing noncardiac chest CT presented ≥1 ICF, independently from sex but increasing with age. Moreover, 69% of detectable ICFs were not originally mentioned.

  8. Diagnostic imaging in paraneoplastic autoimmune multiorgan syndrome: retrospective single site study and literature review of 225 patients.

    PubMed

    Lehman, Vance T; Barrick, Benjamin J; Pittelkow, Mark R; Peller, Patrick J; Camilleri, Michael J; Lehman, Julia S

    2015-04-01

    The utility of diagnostic imaging in paraneoplastic autoimmune multiorgan syndrome (PAMS) is unknown. We examined the role of diagnostic imaging in patients with PAMS evaluated at our tertiary referral center (at Mayo Clinic, Rochester, MN, USA) and in the English literature between January 1, 1996, and August 31, 2012. We included 17 patients from our institution and 208 patients from the literature review. Of these 225 patients, 113 (50.2%) were not known to have a malignancy diagnosis at the time of PAMS diagnosis. Of the 123 patients from our institution and from the literature reported to undergo imaging studies, conventional computed tomography (CT) was the predominant imaging modality (n = 110; 89.4%); 18F-fluorodeoxyglucose (18F-FDG) positron emission tomography (PET)/CT was also used, albeit infrequently (n = 12; 9.8%). When CT was included in imaging to identify or confirm the presence of a malignancy, imaging was successful in all patients who ultimately were diagnosed with an associated malignancy. At our institution, a relatively high percentage (n = 7; 41%) of patients had 18F-FDG PET/CT, which not only identified all tumors found on CT but also facilitated staging of lymphoma and guided biopsy procedures. Diagnostic imaging is frequently utilized in PAMS with unknown malignancy. Both conventional CT and 18F-FDG PET/CT are likely to detect the typical underlying neoplasms. Relative to conventional CT, 18F-FDG PET/CT may provide additional useful information regarding prognosis for the likely underlying malignancies, although there is a paucity of reports describing the use of this modality for this purpose. © 2014 The International Society of Dermatology.

  9. Deterioration of Cortical Bone Microarchitecture: Critical Component of Renal Osteodystrophy Evaluation.

    PubMed

    Sharma, Ashish K; Toussaint, Nigel D; Masterson, Rosemary; Holt, Stephen G; Rajapakse, Chamith S; Ebeling, Peter R; Mohanty, Sindhu T; Baldock, Paul; Elder, Grahame J

    2018-05-23

    Cortical bone is a significant determinant of bone strength and its deterioration contributes to bone fragility. Thin cortices and increased cortical porosity have been noted in patients with chronic kidney disease (CKD), but the "Turnover Mineralization Volume" classification of renal osteodystrophy does not emphasize cortical bone as a key parameter. We aimed to assess trabecular and cortical bone microarchitecture by histomorphometry and micro-CT in patients with CKD G5 and 5D (dialysis). Transiliac bone biopsies were performed in 14 patients undergoing kidney transplantation (n = 12) and parathyroidectomy (n = 2). Structural parameters were analysed by histomorphometry and micro-CT including trabecular bone volume, thickness (TbTh), number (TbN) and separation and cortical thickness (CtTh) and porosity (CtPo). Indices of bone remodelling and mineralisation were obtained and relationships to bone biomarkers examined. Associations were determined by Spearman's or Pearson's rank correlation coefficients. By micro-CT, trabecular parameters were within normal ranges in most patients, but all patients showed very low CtTh (127 ± 44 µm) and high CtPo (60.3 ± 22.5%). CtPo was inversely related to TbN (r = -0.56; p = 0.03) by micro-CT and to TbTh (r = -0.60; p = 0.024) by histomorphometry and correlated to parathyroid hormone values (r = 0.62; p = 0.021). By histomorphometry, bone turnover was high in 50%, low in 21% and normal in 29%, while 36% showed abnormal patterns of mineralization. Significant positive associations were observed between osteoblast surface, osteoclast surface, mineralization surface and bone turnover markers. Deterioration of cortical -microarchitecture despite predominantly normal trabecular parameters reinforces the importance of comprehensive cortical evaluation in patients with CKD. © 2018 S. Karger AG, Basel.

  10. The prevalence of ureaplasma urealyticum, mycoplasma hominis, chlamydia trachomatis and neisseria gonorrhoeae infections, and the rubella status of patients undergoing an initial infertility evaluation

    PubMed Central

    Imudia, Anthony N.; Detti, Laura; Puscheck, Elizabeth E.; Yelian, Frank D.

    2008-01-01

    Purpose To determine the prevalence of positive test for Ureaplasma urealyticum (UU), Mycoplasma hominis (MH), Chlamydia trachomatis (CT), Neisseria gonorrhoeae (NG) infections, and their corresponding Rubella status when undergoing workup for infertility. Methods Retrospective chart review to determine infection status for UU, MH, CT, and NG as determined by cervical swab, as well as the serum Rubella antibody titer. Results A total of 46 patients of the patients reviewed were positive for UU (20.1%), three patients were positive for MH (1.3%), five patients were positive for CT (2.2%) and one patient was positive for NG (0.4%). Rubella immunity was confirmed in 90.3% of patients. Conclusion Approximately one quarter of women presenting to an infertility clinic seeking to conceive were found to have a positive test for UU, MH, CT or NG infection. Additionally, almost 10% of the patients were Rubella non-immune at the time of presentation for infertility evaluation. PMID:18202910

  11. Smoking cessation results in a clinical lung cancer screening program.

    PubMed

    Borondy Kitts, Andrea K; McKee, Andrea B; Regis, Shawn M; Wald, Christoph; Flacke, Sebastian; McKee, Brady J

    2016-07-01

    Lung cancer screening may provide a "teachable moment" for promoting smoking cessation. This study assessed smoking cessation and relapse rates among individuals undergoing follow-up low-dose chest computed tomography (CT) in a clinical CT lung screening program and assessed the influence of initial screening results on smoking behavior. Self-reported smoking status for individuals enrolled in a clinical CT lung screening program undergoing a follow-up CT lung screening exam between 1st February, 2014 and 31st March, 2015 was retrospectively reviewed and compared to self-reported smoking status using a standardized questionnaire at program entry. Point prevalence smoking cessation and relapse rates were calculated across the entire population and compared with exam results. All individuals undergoing screening fulfilled the National Comprehensive Cancer Network Clinical Practice Guidelines in Oncology: Lung Cancer Screening v1.2012(®) high-risk criteria and had an order for CT lung screening. A total of 1,483 individuals underwent a follow-up CT lung screening exam during the study interval. Smoking status at time of follow-up exam was available for 1,461/1,483 (98.5%). A total of 46% (678/1,461) were active smokers at program entry. The overall point prevalence smoking cessation and relapse rates were 20.8% and 9.3%, respectively. Prior positive screening exam results were not predictive of smoking cessation (OR 1.092; 95% CI, 0.715-1.693) but were predictive of reduced relapse among former smokers who had stopped smoking for 2 years or less (OR 0.330; 95% CI, 0.143-0.710). Duration of program enrollment was predictive of smoking cessation (OR 0.647; 95% CI, 0.477-0.877). Smoking cessation and relapse rates in a clinical CT lung screening program rates are more favorable than those observed in the general population. Duration of participation in the screening program correlated with increased smoking cessation rates. A positive exam result correlated with reduced relapse rates among smokers recently quit smoking.

  12. Radiation exposure - how do CT scans for appendicitis compare between a free standing children's hospital and non-dedicated pediatric facilities?

    PubMed

    Sharp, Nicole E; Raghavan, Maneesha U; Svetanoff, Wendy J; Thomas, Priscilla T; Sharp, Susan W; Brown, James C; Rivard, Douglas C; St Peter, Shawn D; Holcomb, George W

    2014-06-01

    We compare the amount of radiation children receive from CT scans performed at non-dedicated pediatric facilities (OH) versus those at a dedicated children's hospital (CH). Using a retrospective chart review, all children undergoing CT scanning for appendicitis at an OH were compared to children undergoing CT imaging for appendicitis at a CH between January 2011 and November 2012. One hundred sixty-three children underwent CT scans at 42 different OH. Body mass index was similar between the two groups (21.00±6.49kg/m(2), 19.58±5.18kg/m(2), P=0.07). Dose length product (DLP) was 620±540.3 at OH and 253.78±211.08 at CH (P < 0.001). OH CT scans accurately diagnosed appendicitis in 81%, while CT scans at CH were accurate in 95% (P=0.026). CTDIvol was recorded in 65 patients with subset analysis showing CTDIvol of 16.98±15.58 and 4.89±2.64, a DLP of 586.25±521.59 and 143.54±41.19, and size-specific dose estimate (SSDE) of 26.71±23.1 and 3.81±2.02 at OH and CH, respectively (P<0.001). Using SSDE as a marker for radiation exposure, children received 86% less radiation and had improved diagnostic accuracy when CT scans are performed at a CH. Copyright © 2014 Elsevier Inc. All rights reserved.

  13. Primary Intimal Sarcoma of Thoracic Aorta Presenting as Hypertensive Crisis.

    PubMed

    Lin, Shu-I; Su, Min-I; Tsai, Cheng-Ting

    2015-11-01

    We report a 45-year-old woman who presented to our facility in a hypertensive crisis. Computed tomography (CT) revealed a thoracic aortic tumor, and tissues obtained via endovascular biopsy revealed undifferentiated sarcoma. A final diagnosis of intimal sarcoma was made by intra-operative pathological examination. Despite undergoing surgical resection followed by adjuvant chemotherapy, the patient died from progressive multiple metastasis and severe sepsis. Although aortic sarcoma is rarely diagnosed, it should be considered a possible etiology of hypertensive crisis. Aortic tumor; Endovascular biopsy; Hypertension crisis; Intimal sarcoma.

  14. Computed tomography use among children presenting to emergency departments with abdominal pain.

    PubMed

    Fahimi, Jahan; Herring, Andrew; Harries, Aaron; Gonzales, Ralph; Alter, Harrison

    2012-11-01

    To evaluate trends in and factors associated with computed tomography (CT) use among children presenting to the emergency department (ED) with abdominal pain. This study was a cross-sectional, secondary analysis of the National Hospital Ambulatory Medical Care Survey data from 1998 to 2008. We identified ED patients aged <19 years with abdominal pain and collected patient demographic and hospital characteristics, and outcomes related to imaging, hospital admission, and diagnosis of appendicitis. Trend analysis was performed over the study period for the outcomes of interest, and a multivariate regression model was used to identify factors associated with CT use. Of all pediatric ED visits, 6.0% were for abdominal pain. We noted a rise in the proportion of these patients with CT use, from 0.9% in 1998 to 15.4% in 2008 (P < .001), with no change in ultrasound/radiograph use, diagnosis of appendicitis, or hospital admission. Older and male patients were more likely to have a CT scan, whereas black children were one-half as likely to undergo a CT scan compared with white children (odds ratio: 0.50 [95% confidence interval: 0.31-0.81]). Admitted children had much higher odds of undergoing a CT scan (odds ratio: 4.11 [95% confidence interval: 2.66-6.35]). There was a plateau in CT use in 2006 to 2008. There was a dramatic increase in the utilization of CT imaging in the ED evaluation of pediatric patients with abdominal pain. Some groups of children may have a differential likelihood of receiving CT scans.

  15. Patient-specific dose calculations for pediatric CT of the chest, abdomen and pelvis

    PubMed Central

    Fraser, Nicholas D.; Carver, Diana E.; Pickens, David R.; Price, Ronald R.; Hernanz-Schulman, Marta; Stabin, Michael G.

    2015-01-01

    Background Organ dose is essential for accurate estimates of patient dose from CT. Objective To determine organ doses from a broad range of pediatric patients undergoing diagnostic chest–abdomen–pelvis CT and investigate how these relate to patient size. Materials and methods We used a previously validated Monte Carlo simulation model of a Philips Brilliance 64 multi-detector CT scanner (Philips Healthcare, Best, The Netherlands) to calculate organ doses for 40 pediatric patients (M:F=21:19; range 0.6–17 years). Organ volumes and positions were determined from the images using standard segmentation techniques. Non-linear regression was performed to determine the relationship between volume CT dose index (CTDIvol)-normalized organ doses and abdominopelvic diameter. We then compared results with values obtained from independent studies. Results We found that CTDIvol-normalized organ dose correlated strongly with exponentially decreasing abdominopelvic diameter (R2>0.8 for most organs). A similar relationship was determined for effective dose when normalized by dose-length product (R2=0.95). Our results agreed with previous studies within 12% using similar scan parameters (i.e. bowtie filter size, beam collimation); however results varied up to 25% when compared to studies using different bowtie filters. Conclusion Our study determined that organ doses can be estimated from measurements of patient size, namely body diameter, and CTDIvol prior to CT examination. This information provides an improved method for patient dose estimation. PMID:26142256

  16. Clinical manifestations that predict abnormal brain computed tomography (CT) in children with minor head injury.

    PubMed

    Alharthy, Nesrin; Al Queflie, Sulaiman; Alyousef, Khalid; Yunus, Faisel

    2015-01-01

    Computed tomography (CT) used in pediatric pediatrics brain injury (TBI) to ascertain neurological manifestations. Nevertheless, this practice is associated with adverse effects. Reports in the literature suggest incidents of morbidity and mortality in children due to exposure to radiation. Hence, it is found imperative to search for a reliable alternative. The aim of this study is to find a reliable clinical alternative to detect an intracranial injury without resorting to the CT. Retrospective cross-sectional study was undertaken in patients (1-14 years) with blunt head injury and having a Glasgow Coma Scale (GCS) of 13-15 who had CT performed on them. Using statistical analysis, the correlation between clinical examination and positive CT manifestation is analyzed for different age-groups and various mechanisms of injury. No statistically significant association between parameteres such as Loss of Consciousness, 'fall' as mechanism of injury, motor vehicle accidents (MVA), more than two discrete episodes of vomiting and the CT finding of intracranial injury could be noted. Analyzed data have led to believe that GCS of 13 at presentation is the only important clinical predictor of intracranial injury. Retrospective data, small sample size and limited number of factors for assessing clinical manifestation might present constraints on the predictive rule that was derived from this review. Such limitations notwithstanding, the decision to determine which patients should undergo neuroimaging is encouraged to be based on clinical judgments. Further analysis with higher sample sizes may be required to authenticate and validate findings.

  17. Relevant incidental findings at abdominal multi-detector contrast-enhanced computed tomography: A collateral screening?

    PubMed Central

    Sconfienza, Luca Maria; Mauri, Giovanni; Muzzupappa, Claudia; Poloni, Alessandro; Bandirali, Michele; Esseridou, Anastassia; Tritella, Stefania; Secchi, Francesco; Di Leo, Giovanni; Sardanelli, Francesco

    2015-01-01

    AIM: To investigate the prevalence of relevant incidental findings (RIFs) detected during routine abdominal contrast-enhanced computed tomography (CeCT). METHODS: We retrospectively evaluated the reports of a consecutive series of abdominal CeCT studies performed between January and May 2013. For each report, patients’ age and sex, admission as inpatient or outpatient, clinical suspicion as indicated by the requesting physician, availability of a previous abdominal examination, and name of the reporting radiologist were recorded. Based on the clinical suspicion, the presence and features of any RIFs (if needing additional workup) was noted. RESULTS: One thousand forty abdominal CeCT were performed in 949 patients (528 males, mean age 66 ± 14 years). No significant difference was found between inpatients and outpatients age and sex distribution (P > 0.472). RIFs were found in 195/1040 (18.8%) CeCT [inpatients = 108/470 (23.0%); outpatients = 87/570 (15.2%); P = 0.002]. RIFs were found in 30/440 (6.8%) CeCT with a previous exam and in 165/600 (27.5%) without a previous exam (P < 0.001). Radiologists’ distribution between inpatients or outpatients was significantly different (P < 0.001). RIFs prevalence increased with aging, except for a peak in 40-49 year group. Most involved organs were kidneys, gallbladder, and lungs. CONCLUSION: A RIF is detected in 1/5 patients undergoing abdominal CeCT. Risk of overdiagnosis should be taken into account. PMID:26516432

  18. Simulation of computed tomography dose based on voxel phantom

    NASA Astrophysics Data System (ADS)

    Liu, Chunyu; Lv, Xiangbo; Li, Zhaojun

    2017-01-01

    Computed Tomography (CT) is one of the preferred and the most valuable imaging tool used in diagnostic radiology, which provides a high-quality cross-sectional image of the body. It still causes higher doses of radiation to patients comparing to the other radiological procedures. The Monte-Carlo method is appropriate for estimation of the radiation dose during the CT examinations. The simulation of the Computed Tomography Dose Index (CTDI) phantom was developed in this paper. Under a similar conditions used in physical measurements, dose profiles were calculated and compared against the measured values that were reported. The results demonstrate a good agreement between the calculated and the measured doses. From different CT exam simulations using the voxel phantom, the highest absorbed dose was recorded for the lung, the brain, the bone surface. A comparison between the different scan type shows that the effective dose for a chest scan is the highest one, whereas the effective dose values during abdomen and pelvis scan are very close, respectively. The lowest effective dose resulted from the head scan. Although, the dose in CT is related to various parameters, such as the tube current, exposure time, beam energy, slice thickness and patient size, this study demonstrates that the MC simulation is a useful tool to accurately estimate the dose delivered to any specific organs for patients undergoing the CT exams and can be also a valuable technique for the design and the optimization of the CT x-ray source.

  19. Oncologic safety of breast conserving surgery after tumour downsizing by neoadjuvant therapy: a retrospective single centre cohort study.

    PubMed

    Fitzal, F; Riedl, O; Mittlböck, M; Dubsky, P; Bartsch, R; Steger, G; Jakesz, R; Gnant, M

    2011-05-01

    The objective of this study is to analyse local recurrence rates in patients receiving neoadjuvant chemotherapy (nCT) comparing mastecomized (MX) patients with those undergoing breast conserving therapy (BCT). Patients undergoing breast cancer surgery after nCT (3xCMF or 3-6xED) between 1995 and 2007 at our department were retrospectively analysed. The median follow up was 60 months for 308 patients. Patients who were downsized from MX to BCT with partial or complete response (n = 104) had a similar local recurrence free survival (LRFS) compared to patients who did not experience successful downsizing (n = 67) and finally undergoing MX (LRFS MX-BCT 81% vs. MX-MX 91%; P = 0.79). Uni- and multivariate analyses demonstrated that BCT itself was not an independent prognostic factor for a worse LRFS (P = 0.07 and 0.14). After no pathologic change or progressive disease the risk of local recurrence was increased in patients undergoing BCT (MX-BCT; n = 6 LRFS 66%) compared with MX (n = 44; LRFS 90%; P = 0.04). Overall survival in general was better for the BCT group (n = 197) compared with MX group (n = 111) regardless of clinical response (92% vs. 72%; P < 0.0001). Breast conservation, nodal negativity and low or medium grade histology were prognostic factors for an improved OS (P = 0.02, 0.01, 0.004). In conclusion, our study suggests that BCT is oncologically safe after tumour downsizing by nCT in patients primarily scheduled for mastectomy. These patients, however, should not be treated with breast conservation in the absence of any proven response after nCT.

  20. Computed tomographic colonography (CTC): a retrospective analysis of a single site experience and a review of the literature on the status of CTC.

    PubMed

    Ghuman, Marcus; Bates, Ngaire; Moore, Helen

    2012-06-08

    To review local CT colonography (CTC) data with regard to demographics, and both colonic and extracolonic findings. To improve performance by identifying any deficiencies that need to be addressed, in relation to a literature review of the current status of CTC. A retrospective observational analysis was conducted of all the patients undergoing CTC for the 3-year period from 9 August 2007 - 12 August 2010 (n=302) conducted at a single site: Greenlane Hospital (ADHB outpatients). In total, 12 of the 302 patients (4%) were found to have cancer, 24 polyps (8%), and 111 diverticular disease (37%). 21 patients (7%) were referred on for optical colonoscopy following their CTC, and 34 patients (11%) had follow-up recommendations resulting from extracolonic findings, including 24 recommendations for further imaging. A trend towards under-representation of both Māori and Pacific Island groups undergoing CTC, and over-representation of Asians was identified. This study has reported on the experience of CT colonography at Greenlane Hospital over a 3-year period. It has provided important local data on rates of detection of colonic pathology. Māori and Pacific Islanders need encouragement from primary health practitioners to present for bowel examination.

  1. Diagnostic value of a pancreatic mass on computed tomography in patients undergoing pancreatoduodenectomy for presumed pancreatic cancer.

    PubMed

    Gerritsen, Arja; Bollen, Thomas L; Nio, C Yung; Molenaar, I Quintus; Dijkgraaf, Marcel G W; van Santvoort, Hjalmar C; Offerhaus, G Johan; Brosens, Lodewijk A; Biermann, Katharina; Sieders, Egbert; de Jong, Koert P; van Dam, Ronald M; van der Harst, Erwin; van Goor, Harry; van Ramshorst, Bert; Bonsing, Bert A; de Hingh, Ignace H; Gerhards, Michael F; van Eijck, Casper H; Gouma, Dirk J; Borel Rinkes, Inne H M; Busch, Olivier R C; Besselink, Marc G H

    2015-07-01

    Previous studies have shown that 5-14% of patients undergoing pancreatoduodenectomy for suspected malignancy ultimately are diagnosed with benign disease. A "pancreatic mass" on computed tomography (CT) is considered to be the strongest predictor of malignancy, but studies describing its diagnostic value are lacking. The aim of this study was to determine the diagnostic value of a pancreatic mass on CT in patients with presumed pancreatic cancer, as well as the interobserver agreement among radiologists and the additional value of reassessment by expert-radiologists. Reassessment of preoperative CT scans was performed within a previously described multicenter retrospective cohort study in 344 patients undergoing pancreatoduodenectomy for suspected malignancy (2003-2010). Preoperative CT scans were reassessed by 2 experienced abdominal radiologists separately and subsequently in a consensus meeting, after defining a pancreatic mass as "a measurable space occupying soft tissue density, except for an enlarged papilla or focal steatosis". CT scans of 86 patients with benign and 258 patients with (pre)malignant disease were reassessed. In 66% of patients a pancreatic mass was reported in the original CT report, versus 48% and 50% on reassessment by the 2 expert radiologists separately and 44% in consensus (P < .001 vs original report). Interobserver agreement between the original CT report and expert consensus was fair (kappa = 0.32, 95% confidence interval 0.23-0.42). Among both expert-radiologists agreement was moderate (kappa = 0.47, 95% confidence interval 0.38-0.56), with disagreement on the presence of a pancreatic mass in 29% of cases. The specificity for malignancy of pancreatic masses identified in expert consensus was twice as high compared with the original CT report (87% vs 42%, respectively). Positive predictive value increased to 98% after expert consensus, but negative predictive value was low (12%). Clinicians need to be aware of potential considerable disagreement among radiologists about the presence of a pancreatic mass. The specificity for malignancy doubled by expert radiologist reassessment when a uniform definition of "pancreatic mass" was used. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. Variations in the intensive use of head CT for elderly patients with hemorrhagic stroke.

    PubMed

    Bekelis, Kimon; Fisher, Elliott S; Labropoulos, Nicos; Zhou, Weiping; Skinner, Jonathan

    2015-04-01

    To investigate the variability in head computed tomographic (CT) scanning in patients with hemorrhagic stroke in U.S. hospitals, its association with mortality, and the number of different physicians consulted. The study was approved by the Committee for the Protection of Human Subjects at Dartmouth College. A retrospective analysis of the Medicare fee-for-service claims data was performed for elderly patients admitted for hemorrhagic stroke in 2008-2009, with 1-year follow-up through 2010. Risk-adjusted primary outcome measures were mean number of head CT scans performed and high-intensity use of head CT (six or more head CT scans performed in the year after admission). We examined the association of high-intensity use of head CT with the number of different physicians consulted and mortality. A total of 53 272 patients (mean age, 79.6 years; 31 377 women [58.9%]) with hemorrhagic stroke were identified in the study period. The mean number of head CT scans conducted in the year after admission for stroke was 3.4; 8737 patients (16.4%) underwent six or more scans. Among the hospitals with the highest case volume (more than 50 patients with hemorrhagic stroke), risk-adjusted rates ranged from 8.0% to 48.1%. The correlation coefficient between number of physicians consulted and rates of high-intensity use of head CT was 0.522 (P < .01) for all hospitals and 0.50 (P < .01) for the highest-volume hospitals. No improvement in 1-year mortality was found for patients undergoing six or more head CT scans (odds ratio, 0.84; 95% confidence interval: 0.69, 1.02). High rates of head CT use for patients with hemorrhagic stroke are frequently observed, without an association with decreased mortality. A higher number of physicians consulted was associated with high-intensity use of head CT. © RSNA, 2014 Online supplemental material is available for this article.

  3. The Effect of the Presence of EEG Leads on Image Quality in Cerebral Perfusion SPECT and FDG PET/CT.

    PubMed

    Zhang, Lulu; Yen, Stephanie P; Seltzer, Marc A; Thomas, George P; Willis, Kristen; Siegel, Alan

    2018-06-08

    Rationale: Cerebral perfusion SPECT and 18 F-FDG PET/CT are commonly performed diagnostic procedures for patients suffering from epilepsy. Individuals receiving these tests are often in-patients undergoing examinations with EEG leads. We have routinely removed these leads before these tests due to concerns that they would lead to imaging artifacts. The leads would then be replaced at the conclusion of the scan. The goal of our study was to determine if the EEG leads actually do cause artifacts that could lead to erroneous scan interpretation or make the scan uninterpretable. Methods: PET/CT with 18 F-FDG and SPECT with technetium-99m ECD were performed on a two dimensional brain phantom. The phantom was scanned with standard leads, CT/MR compatible leads and with no leads. The scans were interpreted by three experienced nuclear medicine physicians who were asked to rank the images by quality and then to determine if they could differentiate each of the scans from a scan in which it was indicated that no leads were present. Results: No differences could be detected between SPECT or PET scans performed without leads or with either set of leads. The standard EEG leads did create an artifact in the CT portion of the PET/CT while the CT/MR compatible leads did not. Conclusion: This phantom study suggest that EEG leads, standard or CT/MR compatible do not need to be removed for SPECT or for PET. Further study evaluating the effect on patients scan would be of value to support this conclusion. Copyright © 2018 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  4. Automatic machine learning based prediction of cardiovascular events in lung cancer screening data

    NASA Astrophysics Data System (ADS)

    de Vos, Bob D.; de Jong, Pim A.; Wolterink, Jelmer M.; Vliegenthart, Rozemarijn; Wielingen, Geoffrey V. F.; Viergever, Max A.; Išgum, Ivana

    2015-03-01

    Calcium burden determined in CT images acquired in lung cancer screening is a strong predictor of cardiovascular events (CVEs). This study investigated whether subjects undergoing such screening who are at risk of a CVE can be identified using automatic image analysis and subject characteristics. Moreover, the study examined whether these individuals can be identified using solely image information, or if a combination of image and subject data is needed. A set of 3559 male subjects undergoing Dutch-Belgian lung cancer screening trial was included. Low-dose non-ECG synchronized chest CT images acquired at baseline were analyzed (1834 scanned in the University Medical Center Groningen, 1725 in the University Medical Center Utrecht). Aortic and coronary calcifications were identified using previously developed automatic algorithms. A set of features describing number, volume and size distribution of the detected calcifications was computed. Age of the participants was extracted from image headers. Features describing participants' smoking status, smoking history and past CVEs were obtained. CVEs that occurred within three years after the imaging were used as outcome. Support vector machine classification was performed employing different feature sets using sets of only image features, or a combination of image and subject related characteristics. Classification based solely on the image features resulted in the area under the ROC curve (Az) of 0.69. A combination of image and subject features resulted in an Az of 0.71. The results demonstrate that subjects undergoing lung cancer screening who are at risk of CVE can be identified using automatic image analysis. Adding subject information slightly improved the performance.

  5. Development of a database of organ doses for paediatric and young adult CT scans in the United Kingdom

    PubMed Central

    Kim, K. P.; Berrington de González, A.; Pearce, M. S.; Salotti, J. A.; Parker, L.; McHugh, K.; Craft, A. W.; Lee, C.

    2012-01-01

    Despite great potential benefits, there are concerns about the possible harm from medical imaging including the risk of radiation-related cancer. There are particular concerns about computed tomography (CT) scans in children because both radiation dose and sensitivity to radiation for children are typically higher than for adults undergoing equivalent procedures. As direct empirical data on the cancer risks from CT scans are lacking, the authors are conducting a retrospective cohort study of over 240 000 children in the UK who underwent CT scans. The main objective of the study is to quantify the magnitude of the cancer risk in relation to the radiation dose from CT scans. In this paper, the methods used to estimate typical organ-specific doses delivered by CT scans to children are described. An organ dose database from Monte Carlo radiation transport-based computer simulations using a series of computational human phantoms from newborn to adults for both male and female was established. Organ doses vary with patient size and sex, examination types and CT technical settings. Therefore, information on patient age, sex and examination type from electronic radiology information systems and technical settings obtained from two national surveys in the UK were used to estimate radiation dose. Absorbed doses to the brain, thyroid, breast and red bone marrow were calculated for reference male and female individuals with the ages of newborns, 1, 5, 10, 15 and 20 y for a total of 17 different scan types in the pre- and post-2001 time periods. In general, estimated organ doses were slightly higher for females than males which might be attributed to the smaller body size of the females. The younger children received higher doses in pre-2001 period when adult CT settings were typically used for children. Paediatric-specific adjustments were assumed to be used more frequently after 2001, since then radiation doses to children have often been smaller than those to adults. The database here is the first detailed organ-specific paediatric CT scan database for the UK. As well as forming the basis for the UK study, the results and description of the methods will also serve as a key resource for paediatric CT scan studies currently underway in other countries. PMID:22228685

  6. Development of a database of organ doses for paediatric and young adult CT scans in the United Kingdom.

    PubMed

    Kim, K P; Berrington de González, A; Pearce, M S; Salotti, J A; Parker, L; McHugh, K; Craft, A W; Lee, C

    2012-07-01

    Despite great potential benefits, there are concerns about the possible harm from medical imaging including the risk of radiation-related cancer. There are particular concerns about computed tomography (CT) scans in children because both radiation dose and sensitivity to radiation for children are typically higher than for adults undergoing equivalent procedures. As direct empirical data on the cancer risks from CT scans are lacking, the authors are conducting a retrospective cohort study of over 240,000 children in the UK who underwent CT scans. The main objective of the study is to quantify the magnitude of the cancer risk in relation to the radiation dose from CT scans. In this paper, the methods used to estimate typical organ-specific doses delivered by CT scans to children are described. An organ dose database from Monte Carlo radiation transport-based computer simulations using a series of computational human phantoms from newborn to adults for both male and female was established. Organ doses vary with patient size and sex, examination types and CT technical settings. Therefore, information on patient age, sex and examination type from electronic radiology information systems and technical settings obtained from two national surveys in the UK were used to estimate radiation dose. Absorbed doses to the brain, thyroid, breast and red bone marrow were calculated for reference male and female individuals with the ages of newborns, 1, 5, 10, 15 and 20 y for a total of 17 different scan types in the pre- and post-2001 time periods. In general, estimated organ doses were slightly higher for females than males which might be attributed to the smaller body size of the females. The younger children received higher doses in pre-2001 period when adult CT settings were typically used for children. Paediatric-specific adjustments were assumed to be used more frequently after 2001, since then radiation doses to children have often been smaller than those to adults. The database here is the first detailed organ-specific paediatric CT scan database for the UK. As well as forming the basis for the UK study, the results and description of the methods will also serve as a key resource for paediatric CT scan studies currently underway in other countries.

  7. Is non-attenuation-corrected PET inferior to body attenuation-corrected PET or PET/CT in lung cancer?

    NASA Astrophysics Data System (ADS)

    Maintas, Dimitris; Houzard, Claire; Ksyar, Rachid; Mognetti, Thomas; Maintas, Catherine; Scheiber, Christian; Itti, Roland

    2006-12-01

    It is considered that one of the great strengths of PET imaging is the ability to correct for body attenuation. This enables better lesion uptake quantification and quality of PET images. The aim of this work is to compare the sensitivity of non-attenuation-corrected (NAC) PET images, the gamma photons (GPAC) and CT attenuation-corrected (CTAC) images in detecting and staging of lung cancer. We have studied 66 patients undergoing PET/CT examinations for detecting and staging NSC lung cancer. The patients were injected with 18-FDG; 5 MBq/kg under fasting conditions and examination was started 60 min later. Transmission data were acquired by a spiral CT X-ray tube and by gamma photons emitting Cs-137l source and were used for the patient body attenuation correction without correction for respiratory motion. In 55 of 66 patients we performed both attenuation correction procedures and in 11 patients only CT attenuation correction. In seven patients with solitary nodules PET was negative and in 59 patients with lung cancer PET/CT was positive for pulmonary or other localization. In the group of 55 patients we found 165 areas of focal increased 18-FDG uptake in NAC, 165 in CTAC and 164 in GPAC PET images.In the patients with only CTAC we found 58 areas of increased 18-FDG uptake on NAC and 58 areas lesions on CTAC. In the patients with positive PET we found 223 areas of focal increased uptake in NAC and 223 areas in CTAC images. The sensitivity of NAC was equal to the sensitivity of CTAC and GPAC images. The visualization of peripheral lesions was better in NAC images and the lesions were better localized in attenuation-corrected images. In three lesions of the thorax the localization was better in GPAC and fused images than in CTAC images.

  8. An anatomical review of spinal cord blood supply.

    PubMed

    Melissano, G; Bertoglio, L; Rinaldi, E; Leopardi, M; Chiesa, R

    2015-10-01

    Knowledge of the spinal cord (SC) vascular supply is important in patients undergoing procedures that involve the thoracic and thoracoabdominal aorta. However, the SC vasculature has a complex anatomy, and teaching is often based only on anatomical sketches with highly variable accuracy; historically, this has required a "leap of faith" on the part of aortic surgeons. Fortunately, this "leap of faith" is no longer necessary given recent breakthroughs in imaging technologies and postprocessing software. Imaging methods have expanded the non-invasive diagnostic ability to determine a patient's SC vascular pattern, particularly in detecting the presence and location of the artery of Adamkiewicz. CT is the imaging modality of choice for most patients with thoracic and thoracoabdominal aortic disease, proving especially useful in the determination of feasibility and planning of endovascular treatment. Thus the data set required for analysis of SC vascular anatomy is usually already available. We have concentrated our efforts on CT angiography, which offers particularly good imaging capabilities with state-of-the-art multidetector scanners. Multidetector row helical CT provides examinations of an extensive range in the craniocaudal direction with thin collimation in a short time interval, giving excellent temporal and spatial resolution. This paper provides examples of the SC vasculature imaging quality that can be obtained with 64 row scanners and appropriate postprocessing. Knowledge of the principal anatomical features of the SC blood supply of individual patients undergoing open or endovascular thoracoabdominal procedures has several potential benefits. For open surgery, analysis of the SC vasculature could tell us the aortic region that feeds the Adamkiewicz artery and thus needs to be reimplanted. For endovascular procedures, we can determine whether the stent-graft will cover the Adamkiewicz artery, thus avoiding unnecessary coverage. CT data can also be used to stratify risk of SC ischemia and guide the selective use of spinal cord injury prevention strategies.

  9. Definitions and outlook targeting x-ray exposure of patients in diagnostic imaging

    NASA Astrophysics Data System (ADS)

    Regulla, Dieter F.

    2011-03-01

    Computer tomography (CT) is vital and currently irreplaceable in diagnostic radiology. But CT operates with ionizing radiation which may cause cancer or non-cancer diseases in humans. The degree of radiation impact depends on the dose administered by an investigation. And this is the core issue: Even CT exams executed lege artis, administer doses to patients which by magnitude are far beyond the level of hitherto known doses of conventional film-screen techniques. Patients undergoing one or multiple CT examinations, digital angiographies or interventions will be exposed to effective doses between roughly several mSv and several 100 mSv depending on type and frequency of the diagnostic investigations. From the radiation protection point of view, there is therefore the worldwide problem of formulating firm rules for the control of these high-dose investigations, as dose limits can not be established for reasons of the medical benefit. This makes the difference compared with radiation protection for occupationally exposed persons. What remains is "software", namely "justification" and "optimization". Justification requires balancing the interests between the health benefit and the potential harm of an exam which has to be responsibly executed by the physician himself; therefore the radiologists' associations are in the duty to prepare practicable rules for justification. Optimization again needs a cooperative solution, and that is the establishment of reference doses for diagnostic examinations, to be checked by the technical service of the producers' companies. Experts and authorities have been aware of the high-dose dilemma in diagnostic imaging since long. It is time for the reflection of active solutions and their implementation into practice.

  10. Improving ultrasound quality to reduce computed tomography use in pediatric appendicitis: the Safe and Sound campaign.

    PubMed

    Kotagal, Meera; Richards, Morgan K; Chapman, Teresa; Finch, Lisa; McCann, Bessie; Ormazabal, Amaya; Rush, Robert J; Goldin, Adam B

    2015-05-01

    Safety concerns about the use of radiation-based imaging such as computed tomography (CT) in children have resulted in national recommendations to use ultrasound (US) for the diagnosis of appendicitis when possible. We evaluated the trends in CT and US use in a statewide sample and the accuracy of these modalities. Patients less than or equal to 18 years undergoing appendectomy in Washington State from 2008 to 2013 were evaluated for preoperative US/CT use, as well as imaging/pathology concordance using data from the Surgical Care and Outcomes Assessment Program. Among 3,353 children, 98.3% underwent preoperative imaging. There was a significant increase in the use of US first over the study period (P < .001). The use of CT at any time during the evaluation decreased. Despite this, in 2013, over 40% of the children still underwent CT imaging. Concordance between US imaging and pathology varied between 40% and 75% at hospitals performing greater than or equal to 10 appendectomies in 2013. Over one third (34.9%) of CT scans performed in the evaluation of children with appendicitis were performed after an indeterminate US. Although the use of US as the first imaging modality to diagnose pediatric appendicitis has increased over the past 5 years, over 40% of children still undergo a CT scan during their preoperative evaluation. Causality for this persistence of CT use is unclear, but could include variability in US accuracy, lack of training, and lack of awareness of the risks of radiation-based imaging. Developing a campaign to focus on continued reduction in CT and increased use of high-quality US should be pursued. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. Fluorine-18-fluorodeoxyglucose positron emission tomography as an objective substitute for CT morphologic response criteria in patients undergoing chemotherapy for colorectal liver metastases.

    PubMed

    Nishioka, Yujiro; Yoshioka, Ryuji; Gonoi, Wataru; Sugawara, Toshitaka; Yoshida, Shuntaro; Hashimoto, Masaji; Shindoh, Junichi

    2018-05-01

    The computed tomography (CT) morphologic response of colorectal liver metastases (CLM) after chemotherapy is reportedly correlated with pathologic response and survival outcomes of patients undergoing surgery. However, they are rather subjective criteria and not evaluable without adequate quality of contrast-enhanced CT images. This study sought the potential use of fluorine-18-fluorodeoxyglucose (FDG) positron emission tomography (PET) as an objective substitute for predicting pathological viability of CLM after chemotherapy. Predictive ability of tumor viability of ≤10% was compared between FDG-PET/CT and contrast-enhanced CT in 34 patients who underwent curative surgical resection for CLM after chemotherapy. The CT morphology and response were defined according to the reported criteria (Chun YS, JAMA 2009). The mean standard uptake value (SUV-mean) in CLM was significantly lower in patients with group 1 and group 2 CT morphology (median, 2.53 and 3.00, respectively) than in group 3 (median, 3.32). The tumor SUV-mean showed moderate correlation with the tumor pathologic viability (r = 0.660, P < 0.0001). A receiver operating characteristic curve analysis revealed that both the tumor SUV-mean (area under the curve [AUC], 0.916; the cut-off value, 3.00) and the CT morphology (AUC, 0.882) have excellent predictive power for ≤10% of tumor viability, while degree of tumor shrinkage showed lower predictive power (AUC, 0.692). FDG-PET shows significant correlation with pathologic viability of CLM after chemotherapy and may offer additional objective information for estimating tumor viability when the CT morphologic response is not evaluable.

  12. Emergency Medicine Myths: Computed Tomography of the Head Prior to Lumbar Puncture in Adults with Suspected Bacterial Meningitis - Due Diligence or Antiquated Practice?

    PubMed

    April, Michael D; Long, Brit; Koyfman, Alex

    2017-09-01

    Various sources purport an association between lumbar puncture and brainstem herniation in patients with intracranial mass effect lesions. Several organizations and texts recommend head computed tomography (CT) prior to lumbar puncture in selected patients. To review the evidence regarding the utility of obtaining head CT prior to lumbar puncture in adults with suspected bacterial meningitis. Observational studies report a risk of post-lumbar puncture brainstem herniation in the presence of intracranial mass effect (1.5%) that is significantly lower than that reported among all patients with bacterial meningitis (up to 13.3%). It is unclear from existing literature whether identifying patients with intracranial mass effect decreases herniation risk. Up to 80% of patients with bacterial meningitis experiencing herniation have no CT abnormalities, and approximately half of patients with intracranial mass effect not undergoing lumbar puncture herniate. Decision rules to selectively perform CT on only those individuals most likely to have intracranial mass effect lesions have not undergone validation. Despite recommendations for immediate antimicrobial therapy prior to imaging, data indicate an association between pre-lumbar puncture CT and antibiotic delays. Recent data demonstrate shortened door-to-antibiotic times and lower mortality from bacterial meningitis after implementation of new national guidelines, which restricted generally accepted CT indications by removing impaired mental status as imaging criterion. Data supporting routine head CT prior to lumbar puncture are limited. Physicians should consider selective CT for those patients at risk for intracranial mass effect lesions based on decision rules or clinical gestalt. Patients undergoing head CT must receive immediate antibiotic therapy. Published by Elsevier Inc.

  13. HIV status and viral loads among men testing positive for rectal gonorrhoea and chlamydia, Maricopa County, Arizona, USA, 2011-2013.

    PubMed

    Taylor, M M; Newman, D R; Gonzalez, J; Skinner, J; Khurana, R; Mickey, T

    2015-04-01

    Men diagnosed with rectal gonorrhoea (GC) and chlamydia (CT) have engaged in unprotected receptive anal intercourse. We reviewed the HIV positivity and HIV viral loads (VLs) of men who had rectal GC and CT testing to evaluate potential HIV acquisition and transmission risk. Rectal GC and CT testing data for men attending the Maricopa County STD clinic during the period from 1 October 2011 to 30 September 2013 were cross-matched with HIV surveillance data to identify men with HIV coinfection. We examined HIV status, HIV diagnosis date, and the values of VL collected nearest to the date of reported rectal infection. During the 2-year time period, 1591 men were tested for rectal GC and CT. Of the men tested, 506 (31.8%) were positive for GC (13.2%), CT (12.2%) or both (6.4%); 119 (23.5%) of those with rectal GC or CT were coinfected with HIV. Among the 275 men with HIV at the time of rectal testing, 54 (19.6%) had no reported VL; 63 (22.9%) had an undetectable VL (< 20 HIV-1 RNA copies/mL) and 158 (57.4%) had a detectable VL collected within 1 year of rectal diagnosis. Mean VL was higher among HIV and rectal GC/CT coinfected cases compared with men with HIV alone (174 316 vs. 57 717 copies/mL, respectively; P = 0.04). Approximately one-third of men undergoing rectal testing were positive for GC or CT and one-quarter of men with rectal GC or CT also had HIV infection. Of the HIV-infected men tested for rectal GC or CT, more than half had a detectable VL collected near the time of rectal testing, demonstrating a risk for transmitting HIV. © 2014 British HIV Association.

  14. Effects of VKORC1 Genetic Polymorphisms on Warfarin Maintenance Dose Requirement in a Chinese Han Population

    PubMed Central

    Yan, Xiaojuan; Yang, Feng; Zhou, Hanyun; Zhang, Hongshen; Liu, Jianfei; Ma, Kezhong; Li, Yi; Zhu, Jun; Ding, Jianqiang

    2015-01-01

    Background VKORC1 is reported to be capable of treating several diseases with thrombotic risk, such as cardiac valve replacement. Some single-nucleotide polymorphisms (SNPs) in VKORC1 are documented to be associated with clinical differences in warfarin maintenance dose. This study explored the correlations of VKORC1–1639 G/A, 1173 C/T and 497 T/G genetic polymorphisms with warfarin maintenance dose requirement in patients undergoing cardiac valve replacement. Material/Methods A total of 298 patients undergoing cardiac valve replacement were recruited. During follow-up, clinical data were recorded. Polymerase chain reaction-restriction fragment length polymorphism (PCR-RFLP) method was applied to detect VKORC1–1639 G/A, 1173 C/T and 497 T/G polymorphisms, and genotypes were analyzed. Results Correlations between warfarin maintenance dose and baseline characteristics revealed statistical significances of age, gender and operation methods with warfarin maintenance dose (all P<0.05). Warfarin maintenance dose in VKORC1–1639 G/A AG + GG carriers was obviously higher than in AA carriers (P<0.001). As compared with patients with TT genotype in VKORC1 1173 C/T, warfarin maintenance dose was apparently higher in patients with CT genotype (P<0.001). Linear regression analysis revealed that gender, operation method, method for heart valve replacement, as well as VKORC1–1639 G/A and 1173 C/T gene polymorphisms were significantly related to warfarin maintenance dose (all P<0.05). Conclusions VKORC1 gene polymorphisms are key genetic factors to affect individual differences in warfarin maintenance dose in patients undergoing cardiac valve replacement; meanwhile, gender, operation method and method for heart valve replacement might also be correlate with warfarin maintenance dose. PMID:26583785

  15. Characteristics and outcomes of secondary nodules identified on initial computed tomography scan for patients undergoing resection for primary non-small cell lung cancer.

    PubMed

    Stiles, Brendon M; Schulster, Michael; Nasar, Abu; Paul, Subroto; Lee, Paul C; Port, Jeffrey L; Altorki, Nasser K

    2015-01-01

    We sought to define the prevalence, malignancy rate, and outcome of secondary nodules (SNs) detected on computed tomography (CT) scan for patients undergoing resection for primary non-small cell lung cancer (NSCLC). In consecutive patients with NSCLC, we reviewed all CT scan reports obtained at diagnosis of the dominant tumor for description of SNs. When resected, pathology was reviewed. Serial CT reports for 2 years postoperatively were evaluated to follow SNs not resected. Among 155 patients, 88 (57%) were found to have SNs. A total of 137 SNs were evaluated (median size, 0.5 cm). Thirty-two nodules were resected at primary resection. Nineteen (61%) resected nodules were benign, whereas 13 (39%) were malignant (8 synchronous primary tumors and 5 lobar metastases). A total of 105 unresected nodules were followed by CT. Of these, 32 (30%) resolved completely, 20 (19%) shrunk, and 28 (27%) were stable, whereas 11 (11%) were lost to follow-up. Fourteen SNs (13%) grew, of which 5 were found to be malignant, each a new primary. Overall 5-year survival was not different between patients with or without SNs (67% vs 64%; P = .88). The prevalence of SNs on CT scan in patients undergoing resection for primary NSCLC is high. Only a low proportion of SNs are ever found to be malignant, predominantly those on the ipsilateral side as the dominant tumor. The presence of SNs has no effect on survival. Patients with SNs, if otherwise appropriately staged, should not be denied surgical therapy. Copyright © 2015. Published by Elsevier Inc.

  16. Changes in cognitive functions and cerebral grey matter and their associations with inflammatory markers, endocrine markers, and APOE genotypes in testicular cancer patients undergoing treatment.

    PubMed

    Amidi, Ali; Agerbæk, Mads; Wu, Lisa M; Pedersen, Anders D; Mehlsen, Mimi; Clausen, Cecilie R; Demontis, Ditte; Børglum, Anders D; Harbøll, Anja; Zachariae, Robert

    2017-06-01

    Evidence suggests that testicular cancer (TC) and its treatment are associated with cognitive impairment. However, the underlying neural substrate and biological mechanisms are poorly understood. This study aimed to investigate changes in cognition and brain grey matter (GM) morphology in TC patients undergoing treatment, and to explore associations with immune markers, endocrine markers, and genotype. Sixty-five patients with stage I-III TC underwent assessment after surgery but prior to further treatment and again 6 months after. Twenty-two patients received chemotherapy (+CT), while 43 did not (-CT). Assessments included neuropsychological testing, whole-brain magnetic resonance imaging, and blood samples. Twenty-five healthy controls (HCs) underwent neuropsychological testing with a matching time interval. A regression-based approach was used to determine cognitive changes and longitudinal voxel-based morphometry (VBM) was performed to investigate changes in GM density in the TC groups. Compared with the HCs, both TC groups showed higher rates of cognitive decline (p < 0.05). A trend towards greater decline was observed in + CT (63.6 %) compared with -CT patients (39.5 %) (p = 0.07). VBM revealed widespread GM reductions in both TC groups, but a group-by-time interaction analysis revealed prefrontal reductions specific to the + CT group (p = 0.02), which were associated with poorer cognitive performance. Poorer cognitive performance was also associated with an increase in tumor necrosis factor alpha in + CT patients. Furthermore, an interaction effect was found between the APOE ε4 genotype and chemotherapy on cognitive performance with ε4 carriers performing significantly worse. These findings provide novel evidence of changes in cognition and brain morphology in TC patients undergoing treatment.

  17. The Added Diagnostic Value of 18F-Fluorodihydroxyphenylalanine PET/CT in the Preoperative Work-Up of Small Bowel Neuroendocrine Tumors.

    PubMed

    Addeo, Pietro; Poncet, Gilles; Goichot, Bernard; Leclerc, Loic; Brigand, Cécile; Mutter, Didier; Romain, Benoit; Namer, Izzie-Jacques; Bachellier, Philippe; Imperiale, Alessio

    2018-04-01

    The precise localization of the primary tumor and/or the identification of multiple primary tumors improves the preoperative work-up in patients with small bowel (SB) neuroendocrine tumor (NET). The present study assesses the diagnostic value of 18 F-fluorodihydroxyphenylalanine ( 18 F-FDOPA) positron emission tomography/computed tomography (PET/CT) during the preoperative wok-up of SB NETs. Between January 2010 and June 2017, all consecutive patients with SB NETs undergoing preoperative 18 F-FDOPA PET/CT and successive resection were analyzed. Preoperative work-up included computed tomography (CT), somatostatin receptor scintigraphy (SRS), and 18 F-FDOPA PET/CT. Sensitivity and accuracy ratio for primary and multiple tumor detection were compared with data from surgery and pathology. There were 17 consecutive patients with SB NETs undergoing surgery. Nine patients (53%) had multiple tumors, 15 (88%) metastatic lymph nodes, 3 (18%) peritoneal carcinomatosis, and 9 patients (53%) liver metastases. A total of 70 SB NETs were found by pathology. Surgery identified the primary in 17/17 (100%) patients and recognized seven of 9 patients (78%) with multiple synchronous SB. Preoperatively, 18 F-FDOPA PET/CT displayed a statistically significant higher sensitivity for primary tumor localization (100 vs. 23.5 vs. 29.5%) and multiple tumor detection (78 vs. 22 vs. 11%) over SRS and CT. Compared with pathology, 18 F-FDOPA PET/CT displayed the highest accuracy ratio for number of tumor detected over CT and SRS (2.0 ± 2.2 vs. 0.4 ± 0.7 vs. 0.6 ± 1.5, p = 0.0003). 18 F-FDOPA PET/CT significantly increased the sensitivity and accuracy for primary and multiple SB NET identification. 18 F-FDOPA PET/CT should be included systematically in the preoperative work-up of SB NET.

  18. Total thyroidectomy with ultrasonic dissector for cancer: multicentric experience

    PubMed Central

    2012-01-01

    Background We conducted an observational multicentric clinical study on a cohort of patients undergoing thyroidectomy for thyroid carcinoma. The aim of this study was to evaluate the benefits of the use of ultrasonic dissector (UAS) vs. the use of a conventional technique (vessel clamp and tie) in patients undergoing thyroid surgery for cancer. Methods From June 2009 to May 2010 we evaluated 321 consecutive patients electively admitted to undergo total thyroidectomy for thyroid carcinoma. The first 201 patients (89 males, 112 females) presenting to our Department underwent thyroidectomy with the use of UAS while the following 120 patients (54 males, 66 females) underwent thyroidectomy performed with a conventional technique (CT): vessel clamp and tie. Results The operative time (mean: 75 min in UAS vs. 113 min in CT, range: 54 to 120 min in UAS vs. 68 to 173 min in CT) was much shorter in the group of thyroidectomies performed with UAS. The incidence of transient laryngeal nerve palsy (UAS 3/201 patients (1.49%); CT 1/120 patients (0.83%)) was higher in the group of UAS; the incidence of permanent laryngeal nerve palsy was similar in the two groups (UAS 2/201 patients (0.99%) vs. CT 2/120 patients (1.66%)). The incidence of transient hypocalcaemia (UAS 17/201 patients (8.4%) vs. CT 9/120 patients (7.5%)) was higher in the UAS group; no relevant differences were reported in the incidence of permanent hypocalcaemia in the two groups (UAS 5/201 patients (2.48%) vs. 2/120 patients (1.66%)). Also the average postoperative length of stay was similar in two groups (2 days). Conclusion The only significant advantage proved by this study is represented by the cost-effectiveness (reduction of the usage of operating room) for patients treated with UAS, secondary to the significant reduction of the operative time. The analysis failed to show any advantages in terms of postoperative transient complications in the group of patients treated with ultrasonic dissector: transient laryngeal nerve palsy (1.49% in UAS vs. 0.83% in CT) and transient hypocalcaemia (8.4% in UAS vs. 7.5%in CT). No significant differences in the incidence of permanent laryngeal nerve palsy (0.8% in UAS vs. 1.04% in CT) and permanent hypocalcaemia (2.6% in UAS vs. 2.04% in CT) were demonstrated. The level of surgeons’ expertise is a central factor, which can influence the complications rate; the use of UAS can only help surgical action but cannot replace the experience of the operator. PMID:22540914

  19. 77 FR 45342 - Maxfield and Oberton Holdings, LLC; Complaint

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-31

    ..., including x-rays and monitoring for infection and internal damage. 27. Since March 2009 to approximately... had to undergo x-rays, CT scans, endoscopy, and an appendectomy to remove them. The girl's father had... attraction of the magnets to the metal equipment used to retrieve the magnets. 22. Children who undergo...

  20. Development of a computed tomography-based scoring system for necrotizing soft-tissue infections.

    PubMed

    McGillicuddy, Edward A; Lischuk, Andrew W; Schuster, Kevin M; Kaplan, Lewis J; Maung, Adrian; Lui, Felix Y; Bokhari, S A Jamal; Davis, Kimberly A

    2011-04-01

    Necrotizing soft-tissue infections (NSTIs) are associated with significant morbidity and mortality, but a definitive nonsurgical diagnostic test remains elusive. Despite the widespread use of computed tomography (CT) as a diagnostic adjunct, there is little data that definitively correlate CT findings with the presence of NSTI. Our goal was the development of a CT-based scoring system to discriminate non-NSTI from NSTI. Patients older than 17 years undergoing CT for evaluation of soft-tissue infection at a tertiary care medical center over a 10-year period (2000-2009) were included. Abstracted data included comorbidities and social history, physical examination, laboratory findings, and operative and pathologic findings. NSTI was defined as soft-tissue necrosis in the dictated operative note or the accompanying pathology report. CT scans were reviewed by a radiologist blinded to clinical and laboratory data. A scoring system was developed and the area under the receiver operating characteristic curve was calculated. During the study period, 305 patients underwent CT scanning (57% men; mean age, 47.4 years). Forty-four patients (14.4%) evaluated had an NSTI. A scoring system was retrospectively developed (table). A score >6 points was 86.3% sensitive and 91.5% specific for the diagnosis of NSTI (positive predictive value, 63.3%; negative predictive value, 85.5%). The area under the receiver operating characteristic curve was 0.928 (95% confidence interval, 0.893-0.964). The mean score of the non-NSTI group was 2.74. We have developed a CT scoring system that is both sensitive and specific for the diagnosis of NSTIs. This system may allow clinicians to more accurately diagnose NSTIs. Prospective validation of this scoring system is planned.

  1. Smoking cessation results in a clinical lung cancer screening program

    PubMed Central

    McKee, Andrea B.; Regis, Shawn M.; Wald, Christoph; Flacke, Sebastian; McKee, Brady J.

    2016-01-01

    Background Lung cancer screening may provide a “teachable moment” for promoting smoking cessation. This study assessed smoking cessation and relapse rates among individuals undergoing follow-up low-dose chest computed tomography (CT) in a clinical CT lung screening program and assessed the influence of initial screening results on smoking behavior. Methods Self-reported smoking status for individuals enrolled in a clinical CT lung screening program undergoing a follow-up CT lung screening exam between 1st February, 2014 and 31st March, 2015 was retrospectively reviewed and compared to self-reported smoking status using a standardized questionnaire at program entry. Point prevalence smoking cessation and relapse rates were calculated across the entire population and compared with exam results. All individuals undergoing screening fulfilled the National Comprehensive Cancer Network Clinical Practice Guidelines in Oncology: Lung Cancer Screening v1.2012® high-risk criteria and had an order for CT lung screening. Results A total of 1,483 individuals underwent a follow-up CT lung screening exam during the study interval. Smoking status at time of follow-up exam was available for 1,461/1,483 (98.5%). A total of 46% (678/1,461) were active smokers at program entry. The overall point prevalence smoking cessation and relapse rates were 20.8% and 9.3%, respectively. Prior positive screening exam results were not predictive of smoking cessation (OR 1.092; 95% CI, 0.715–1.693) but were predictive of reduced relapse among former smokers who had stopped smoking for 2 years or less (OR 0.330; 95% CI, 0.143–0.710). Duration of program enrollment was predictive of smoking cessation (OR 0.647; 95% CI, 0.477–0.877). Conclusions Smoking cessation and relapse rates in a clinical CT lung screening program rates are more favorable than those observed in the general population. Duration of participation in the screening program correlated with increased smoking cessation rates. A positive exam result correlated with reduced relapse rates among smokers recently quit smoking. PMID:27606076

  2. The utility of 64 channel multidetector CT angiography for evaluating the renal vascular anatomy and possible variations: a pictorial essay.

    PubMed

    Kumar, Sheo; Neyaz, Zafar; Gupta, Archna

    2010-01-01

    The increased use of laparoscopic nephrectomy and nephron-sparing surgery has prompted the need for a more detailed radiological evaluation of the renal vascular anatomy. Multidetector CT angiography is a fast and accurate modality for assessing the precise anatomy of the renal vessels. In this pictorial review, we present the multidetector CT angiography appearances of the normal renal vascular anatomy and a spectrum of various anomalies that require accurate vascular depiction before undergoing surgical treatment.

  3. Incidental physiological sliding hiatal hernia: a single center comparison study between CT with water enema and CT colonography.

    PubMed

    Revelli, Matteo; Furnari, Manuele; Bacigalupo, Lorenzo; Paparo, Francesco; Astengo, Davide; Savarino, Edoardo; Rollandi, Gian Andrea

    2015-08-01

    Hiatal hernia is a well-known factor impacting on most mechanisms underlying gastroesophageal reflux, related with the risk of developing complications such as erosive esophagitis, Barrett's esophagus and ultimately, esophageal adenocarcinoma. It is our firm opinion that an erroneous reporting of hiatal hernia in CT exams performed with colonic distention may trigger a consecutive diagnostic process that is not only unnecessary, inducing a unmotivated anxiety in the patient, but also expensive and time-consuming for both the patient and the healthcare system. The purposes of our study were to determine whether colonic distention at CT with water enema and CT colonography can induce small sliding hiatal hernias and to detect whether hiatal hernias size modifications could be considered significant for both water and gas distention techniques. We retrospectively evaluated 400 consecutive patients, 200 undergoing CT-WE and 200 undergoing CTC, including 59 subjects who also underwent a routine abdominal CT evaluation on a different time, used as internal control, while a separate group of 200 consecutive patients who underwent abdominal CT evaluation was used as external control. Two abdominal radiologists assessed the CT exams for the presence of a sliding hiatal hernia, grading the size as small, moderate, or large; the internal control groups were directly compared with the corresponding CT-WE or CTC study looking for a change in hernia size. We used the Student's t test applying a size-specific correction factor, in order to account for the effect of colonic distention: these "corrected" values were then individually compared with the external control group. A sliding hiatal hernia was present in 51 % (102/200) of the CT-WE patients and in 48.5 % (97/200) of the CTC patients. Internal control CT of the 31 patients with a hernia at CT-WE showed resolution of the hernia in 58.1 % (18/31) of patients, including 76.5 % (13/17) and 45.5 % (5/11) of small and moderate hernias. Comparison CT of the 28 patients with a hiatal hernia at CTC showed the absence of the hernia in 57.1 % (16/28) patients, including 68.8 % (11/16) and 50 % (5/10) of small and moderate hernias. The prevalence of sliding hiatal hernias in the external control group was 22 % (44/200), significantly lower than the CT-WE and CTC cohorts' prevalence of 51 % (p < 0.0001) and 48.5 % (p < 0.0001). After applying the correction factors for the CT-WE and the CTC groups, the estimated residual prevalences (16 and 18.5 %, respectively) were much closer to that of the external control patients (p = 0.160 for CT-WE and p = 0.455 for CTC). We believe that incidental findings at CT-WE and CTC should be considered according to the clinical background, and that small sliding hiatal hernias should not be reported in patients with symptoms not related to reflux disease undergoing CT-WE or CTC: When encountering these findings, accurate anamnesis and review of medical history looking for GERD-related symptoms are essential, in order to address these patients to a correct diagnostic iter, taking advantage from more appropriate techniques such as endoscopy or functional techniques.

  4. Cost analysis of colorectal cancer screening with CT colonography in Italy.

    PubMed

    Mantellini, Paola; Lippi, Giuseppe; Sali, Lapo; Grazzini, Grazia; Delsanto, Silvia; Mallardi, Beatrice; Falchini, Massimo; Castiglione, Guido; Carozzi, Francesca Maria; Mascalchi, Mario; Milani, Stefano; Ventura, Leonardo; Zappa, Marco

    2018-06-01

    Unit costs of screening CT colonography (CTC) can be useful for cost-effectiveness analyses and for health care decision-making. We evaluated the unit costs of CTC as a primary screening test for colorectal cancer in the setting of a randomized trial in Italy. Data were collected within the randomized SAVE trial. Subjects were invited to screening CTC by mail and requested to have a pre-examination consultation. CTCs were performed with 64- and 128-slice CT scanners after reduced or full bowel preparation. Activity-based costing was used to determine unit costs per-process, per-participant to screening CTC, and per-subject with advanced neoplasia. Among 5242 subjects invited to undergo screening CTC, 1312 had pre-examination consultation and 1286 ultimately underwent CTC. Among 129 subjects with a positive CTC, 126 underwent assessment colonoscopy and 67 were ultimately diagnosed with advanced neoplasia (i.e., cancer or advanced adenoma). Cost per-participant of the entire screening CTC pathway was €196.80. Average cost per-participant for the screening invitation process was €17.04 and €9.45 for the pre-examination consultation process. Average cost per-participant of the CTC execution and reading process was €146.08 and of the diagnostic assessment colonoscopy process was €24.23. Average cost per-subject with advanced neoplasia was €3777.30. Cost of screening CTC was €196.80 per-participant. Our data suggest that the more relevant cost of screening CTC, amenable of intervention, is related to CTC execution and reading process.

  5. Full dose reduction potential of statistical iterative reconstruction for head CT protocols in a predominantly pediatric population

    PubMed Central

    Mirro, Amy E.; Brady, Samuel L.; Kaufman, Robert. A.

    2016-01-01

    Purpose To implement the maximum level of statistical iterative reconstruction that can be used to establish dose-reduced head CT protocols in a primarily pediatric population. Methods Select head examinations (brain, orbits, sinus, maxilla and temporal bones) were investigated. Dose-reduced head protocols using an adaptive statistical iterative reconstruction (ASiR) were compared for image quality with the original filtered back projection (FBP) reconstructed protocols in phantom using the following metrics: image noise frequency (change in perceived appearance of noise texture), image noise magnitude, contrast-to-noise ratio (CNR), and spatial resolution. Dose reduction estimates were based on computed tomography dose index (CTDIvol) values. Patient CTDIvol and image noise magnitude were assessed in 737 pre and post dose reduced examinations. Results Image noise texture was acceptable up to 60% ASiR for Soft reconstruction kernel (at both 100 and 120 kVp), and up to 40% ASiR for Standard reconstruction kernel. Implementation of 40% and 60% ASiR led to an average reduction in CTDIvol of 43% for brain, 41% for orbits, 30% maxilla, 43% for sinus, and 42% for temporal bone protocols for patients between 1 month and 26 years, while maintaining an average noise magnitude difference of 0.1% (range: −3% to 5%), improving CNR of low contrast soft tissue targets, and improving spatial resolution of high contrast bony anatomy, as compared to FBP. Conclusion The methodology in this study demonstrates a methodology for maximizing patient dose reduction and maintaining image quality using statistical iterative reconstruction for a primarily pediatric population undergoing head CT examination. PMID:27056425

  6. Image mottle in abdominal CT.

    PubMed

    Ende, J F; Huda, W; Ros, P R; Litwiller, A L

    1999-04-01

    To investigate image mottle in conventional CT images of the abdomen as a function of radiographic technique factors and patient size. Water-filled phantoms simulating the abdomens of adult (32 cm in diameter) and pediatric (16 cm in diameter) patients were used to investigate image mottle in CT as a function of x-ray tube potential and mAs. CT images from 39 consecutive patients with noncontrast liver scans and 49 patients with iodine contrast scans were analyzed retrospectively. Measurements were made of the mean liver parenchyma Hounsfield unit value and the corresponding image mottle. For a given water phantom and x-ray tube potential, image mottle was proportional to the mAs-0.5. Increasing the phantom diameter from 16 cm (pediatric) to 32 cm increased the mottle by a factor of 2.4, and increasing the x-ray tube potential from 80 kVp to 140 kVp reduced the mottle by a factor of 2.5. All patients were scanned at 120 kVp, with no correlation between patient size and the x-ray tube mAs. The mean mottle level was 7.8 +/- 2.2 and 10.0 +/- 2.5 for the noncontrast and contrast studies, respectively. An increase in patient diameter of 3 cm would require approximately 65% more mAs to maintain the same level of image mottle. The mottle in abdominal CT images may be controlled by adjusting radiographic technique factors, which should be adjusted to take into account the size of the patient undergoing the examination.

  7. [Topography of ischemic strokes in Abidjan (Côte d'Ivoire): a computed tomographic approach].

    PubMed

    Cowppli-Bony, Pascale; Yapi-Yapo, Paulette; Douayoua-Sonan, Thérèse; Kouamé, Blaise; Yapo, Félix Boa; Kouassi, Ernest Beugré

    2006-01-01

    The authors used computed tomography (CT) to assess and categorize the topography of ischemic strokes (IS) among blacks living in Abidjan, the commercial and administrative center of Côte d'Ivoire, in West Africa. This retrospective study analyzed CT data of patients admitted to the Sainte Anne Marie Polyclinic (the principal private hospital in the country) and to the neurology department of the university hospital center in Cocody, from January 1, 2000, to December 31, 2001. The study included patients who met World Health Organisation criteria for stroke and had CT performed during the hospitalization for this stroke. We examined CT data to find early and late signs of IS, analyze lesion diameter (15 mm cutoff used to distinguish infarcts from lacuna), and determine their topography (cerebral arterial territory and localization, that is, brain lobes, basal ganglia and posterior cerebral fossa). We included 260 subjects (58% males) with a median age of 45 years (range: 20-80 years). CT findings were abnormal for 224 patients with infarcts (72.7%), lacuna (27.3%), or both (8%). As reported elsewhere, the anterior arterial territory was most often affected (83.9%) with a middle cerebral artery lesion in 79.4% of patients. Posterior territory (16.1%) lesions and lacuna were probably underestimated because CT exploration is reported to be less useful for this area than for the carotid area. On the other hand, CT diagnoses infarcts more easily than it does lacuna. CT was normal for 36 patients although performed no more than 3 days after IS. These patients did not undergo CT angiography, which might have shown cerebral artery occlusion. Our study included IS of all types and typography. Stroke registries in Africa would provide useful data for better assessment of prevalence for specific topographic and etiologic types of stroke.

  8. Diagnostic Accuracy of Computed Tomography Angiography as Compared to Conventional Angiography in Patients Undergoing Noncoronary Cardiac Surgery

    PubMed Central

    Joshi, Hasit; Shah, Ronak; Prajapati, Jayesh; Bhangdiya, Vipin; Shah, Jayal; Kandre, Yogini; Shah, Komal

    2016-01-01

    Objective: To compare the diagnostic accuracy of multi-slice computed tomography (MSCT) angiography with conventional angiography in patients undergoing major noncoronary cardiac surgeries. Materials and Methods: We studied fifty major noncoronary cardiac surgery patients scheduled for invasive coronary angiography, 29 (58%) female and 21 (42%) male. Inclusion criteria of the study were age of the patients ≥40 years, having low or intermediate probability of coronary artery disease (CAD), left ventricular ejection fraction (LVEF) >35%, and patient giving informed consent for undergoing MSCT and conventional coronary angiography. The patients with LVEF <35%, high pretest probability of CAD, and hemodynamically unstable were excluded from the study. Results: The diagnostic accuracy of CT coronary angiography was evaluated regarding true positive, true negative values. The overall sensitivity and specificity of CT angiography technique was 100% (95% confidence interval [CI]: 39.76%–100%) and 91.30% (95% CI: 79.21%–97.58%). The positive (50%; 95% CI: 15.70%–84.30%) and negative predictive values (100%; 95% CI: 91.59%–100%) of CT angiography were also fairly high in these patients. Conclusion: Our study suggests that this non-invasive technique may improve perioperative risk stratification in patients undegoing non-cardiac surgery. PMID:27867455

  9. Preoperative predictive model of cervical lymph node metastasis combining fluorine-18 fluorodeoxyglucose positron-emission tomography/computerized tomography findings and clinical factors in patients with oral or oropharyngeal squamous cell carcinoma.

    PubMed

    Mochizuki, Yumi; Omura, Ken; Nakamura, Shin; Harada, Hiroyuki; Shibuya, Hitoshi; Kurabayashi, Toru

    2012-02-01

    This study aimed to construct a preoperative predictive model of cervical lymph node metastasis using fluorine-18 fluorodeoxyglucose positron-emission tomography/computerized tomography ((18)F-FDG PET/CT) findings in patients with oral or oropharyngeal squamous cell carcinoma (SCC). Forty-nine such patients undergoing preoperative (18)F-FDG PET/CT and neck dissection or lymph node biopsy were enrolled. Retrospective comparisons with spatial correlation between PET/CT and the anatomical sites based on histopathological examinations of surgical specimens were performed. We calculated a logistic regression model, including the SUVmax-related variable. When using the optimal cutoff point criterion of probabilities calculated from the model that included either clinical factors and delayed-phase SUVmax ≥0.087 or clinical factors and maximum standardized uptake (SUV) increasing rate (SUV-IR) ≥ 0.100, it significantly increased the sensitivity, specificity, and accuracy (87.5%, 65.7%, and 75.2%, respectively). The use of predictive models that include clinical factors and delayed-phase SUVmax and SUV-IR improve preoperative nodal diagnosis. Copyright © 2012 Elsevier Inc. All rights reserved.

  10. Selection of symptomatic patients with Crohn's disease for abdominopelvic computed tomography: role of serum C-reactive protein.

    PubMed

    Desmond, Alan N; O'Regan, Kevin; Malik, Neera; McWilliams, Sebastian; O'Neill, Siobhan; Quigley, Eamonn M; Shanahan, Fergus; Maher, Michael M

    2012-11-01

    Results of previous studies have shown that repeated abdominopelvic computed tomography (CT) examinations can lead to substantial cumulative diagnostic radiation exposure in patients with Crohn's disease (CD). Improved selection of patients referred for CT will reduce unnecessary radiation exposure. This study examines if serum C-reactive protein (CRP) concentration predicts which symptomatic patients with CD are likely to have significant disease activity or disease complications (such as abscess) detected on abdominopelvic CT. All abdominopelvic CTs performed on patients with CD at a tertiary referral centre during the period June 2003 to June 2008 were identified. CT findings were coded by a pair of independent blinded senior radiologists for (i) small bowel luminal disease, (ii) large bowel luminal disease, (iii) mesenteric inflammatory changes, (iv) penetrating disease (fistulas, abscess, or phlegmon), (v) acute disease complications (obstruction or perforation), and (vi) acute non-CD findings. Imaging findings were correlated with serum CRP checked within 14 days before imaging. The reference range for CRP was defined as 0-5 mg/L. A total of 147 patients with symptomatic CD had a CRP assay performed within 14 days before undergoing abdominopelvic CT. The median time from CRP assay to imaging was 2 days (interquartile range, 0-6 days). Median CRP before imaging was 24 mg/L (interquartile range, 6-88 mg/L). CT was normal in 34 of 147 case (23.1%). Patients with normal CRP (n = 36) were significantly less likely to have penetrating disease (odds ratio [OR], 0.04 [95% confidence interval {CI}, 0.01-0.7]; P < .001) or large bowel luminal disease (OR, 0.3 [95% CI, 0.1-0.8]; P < .05). Normal CRP excluded penetrating disease with a sensitivity of 1.0 (95% CI, 0.87-1.0). CRP levels did not correlate with the presence of small bowel luminal disease (n = 82), mesenteric inflammatory changes (n = 68), or acute disease complications (n = 10). Symptomatic patients with CD and normal serum CRP are unlikely to have evidence of abscess, fistulating disease, or large bowel luminal disease detected on abdominopelvic CT. However, abdominopelvic CT may demonstrate evidence of clinically significant non-penetrating CD or complications, including perforation and acute obstruction, regardless of serum CRP concentration. Copyright © 2012 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.

  11. Organizing Principles of Human Cortical Development--Thickness and Area from 4 to 30 Years: Insights from Comparative Primate Neuroanatomy.

    PubMed

    Amlien, Inge K; Fjell, Anders M; Tamnes, Christian K; Grydeland, Håkon; Krogsrud, Stine K; Chaplin, Tristan A; Rosa, Marcello G P; Walhovd, Kristine B

    2016-01-01

    The human cerebral cortex undergoes a protracted, regionally heterogeneous development well into young adulthood. Cortical areas that expand the most during human development correspond to those that differ most markedly when the brains of macaque monkeys and humans are compared. However, it remains unclear to what extent this relationship derives from allometric scaling laws that apply to primate brains in general, or represents unique evolutionary adaptations. Furthermore, it is unknown whether the relationship only applies to surface area (SA), or also holds for cortical thickness (CT). In 331 participants aged 4 to 30, we calculated age functions of SA and CT, and examined the correspondence of human cortical development with macaque to human expansion, and with expansion across nonhuman primates. CT followed a linear negative age function from 4 to 30 years, while SA showed positive age functions until 12 years with little further development. Differential cortical expansion across primates was related to regional maturation of SA and CT, with age trajectories differing between high- and low-expanding cortical regions. This relationship adhered to allometric scaling laws rather than representing uniquely macaque-human differences: regional correspondence with human development was as large for expansion across nonhuman primates as between humans and macaque. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  12. The potential of positron emission tomography/computerized tomography (PET/CT) scanning as a detector of high-risk patients with oral infection during preoperative staging.

    PubMed

    Yamashiro, Keisuke; Nakano, Makoto; Sawaki, Koichi; Okazaki, Fumihiko; Hirata, Yasuhisa; Takashiba, Shogo

    2016-08-01

    It is sometimes difficult to determine during the preoperative period whether patients have oral infections; these patients need treatment to prevent oral infection-related complications from arising during medical therapies, such as cancer therapy and surgery. One of the reasons for this difficulty is that basic medical tests do not identify oral infections, including periodontitis and periapical periodontitis. In this report, we investigated the potential of positron emission tomography/computerized tomography (PET/CT) as a diagnostic tool in these patients. We evaluated eight patients during the preoperative period. All patients underwent PET/CT scanning and were identified as having the signs of oral infection, as evidenced by (18)F-fludeoxyglucose (FDG) localization in the oral regions. Periodontal examination and orthopantomogram evaluation showed severe infection or bone resorption in the oral regions. (18)F-FDG was localized in oral lesions, such as severe periodontitis, apical periodontitis, and pericoronitis of the third molar. The densities of (18)F-FDG were proportional to the degree of inflammation. PET/CT is a potential diagnostic tool for oral infections. It may be particularly useful in patients during preoperative staging, as they frequently undergo scanning at this time, and those identified as having oral infections at this time require treatment before cancer therapy or surgery. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Prevalence of ear disease in dogs undergoing multidetector thin-slice computed tomography of the head.

    PubMed

    Foster, Allison; Morandi, Federica; May, Elizabeth

    2015-01-01

    Previous reports describing the prevalence of ear diseases in dogs have primarily been based on dogs presenting with clinical signs of disease. The prevalence of subclinical ear disease remains unknown. The purpose of this cross-sectional retrospective study was to describe the prevalence of lesions consistent with middle and external ear disease in dogs presented for multidetector computed tomography (CT) of the head and/or cranial cervical spine at our hospital during the period of July 2011 and August 2013. For each included dog, data recorded were signalment, CT findings, diagnosis, and treatment. A total of 199 dogs met inclusion criteria. Nineteen dogs (9.5%) were referred for evaluation of suspected ear disease and 27 dogs (13.5%) had histories or physical examination findings consistent with otitis externa. A total of 163 dogs (81.9%) had CT lesions consistent with external ear disease (i.e. ear canal mineralization, external canal thickening, and/or narrowing of the external canal). Thirty-nine dogs (19.5%) had CT lesions consistent with middle ear disease (i.e. soft tissue attenuating/fluid material in the tympanic bullae, bulla wall thickening or lysis, and/or periosteal proliferation of the temporal bone). Findings from this study indicated that the prevalence of external and middle ear disease in dogs could be higher than that previously reported. © 2014 American College of Veterinary Radiology.

  14. Neurologic abnormalities in murderers.

    PubMed

    Blake, P Y; Pincus, J H; Buckner, C

    1995-09-01

    Thirty-one individuals awaiting trial or sentencing for murder or undergoing an appeal process requested a neurologic examination through legal counsel. We attempted in each instance to obtain EEG, MRI or CT, and neuropsychological testing. Neurologic examination revealed evidence of "frontal" dysfunction in 20 (64.5%). There were symptoms or some other evidence of temporal lobe abnormality in nine (29%). We made a specific neurologic diagnosis in 20 individuals (64.5%), including borderline or full mental retardation (9) and cerebral palsy (2), among others. Neuropsychological testing revealed abnormalities in all subjects tested. There were EEG abnormalities in eight of the 20 subjects tested, consisting mainly of bilateral sharp waves with slowing. There were MRI or CT abnormalities in nine of the 19 subjects tested, consisting primarily of atrophy and white matter changes. Psychiatric diagnoses included paranoid schizophrenia (8), dissociative disorder (4), and depression (9). Virtually all subjects had paranoid ideas and misunderstood social situations. There was a documented history of profound, protracted physical abuse in 26 (83.8%) and of sexual abuse in 10 (32.3%). It is likely that prolonged, severe physical abuse, paranoia, and neurologic brain dysfunction interact to form the matrix of violent behavior.

  15. A Comparison of Lumpectomy Cavity Delineations Between Use of Magnetic Resonance Imaging and Computed Tomography Acquired With Patient in Prone Position for Radiation Therapy Planning of Breast Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huang, Wei; Department of Radiation Oncology, Shandong's Key Laboratory of Radiation Oncology, Shandong Cancer Hospital and Institute, Jinan; Currey, Adam

    2016-03-15

    Purpose: To compare lumpectomy cavity (LC) and planning target volume (PTV) delineated with the use of magnetic resonance imaging (MRI) and computed tomography (CT) and to examine the possibility of replacing CT with MRI for radiation therapy (RT) planning for breast cancer. Methods and Materials: MRI and CT data were acquired for 15 patients with early-stage breast cancer undergoing lumpectomy during RT simulation in prone positions, the same as their RT treatment positions. The LCs were delineated manually on both CT (LC-CT) and MRI acquired with 4 sequences: T1, T2, STIR, and DCE. Various PTVs were created by expanding amore » 15-mm margin from the corresponding LCs and from the union of the LCs for the 4 MRI sequences (PTV-MRI). Differences were measured in terms of cavity visualization score (CVS) and dice coefficient (DC). Results: The mean CVSs for T1, T2, STIR, DCE, and CT defined LCs were 3.47, 3.47, 3.87, 3.50. and 2.60, respectively, implying that the LC is mostly visible with a STIR sequence. The mean reductions of LCs from those for CT were 22%, 43%, 36%, and 17% for T1, T2, STIR, and DCE, respectively. In 14 of 15 cases, MRI (union of T1, T2, STIR, and DCE) defined LC included extra regions that would not be visible from CT. The DCs between CT and MRI (union of T1, T2, STIR, and DCE) defined volumes were 0.65 ± 0.20 for LCs and 0.85 ± 0.06 for PTVs. There was no obvious difference between the volumes of PTV-MRI and PTV-CT, and the average PTV-STIR/PTV-CT volume ratio was 0.83 ± 0.23. Conclusions: The use of MRI improves the visibility of LC in comparison with CT. The volumes of LC and PTV generated based on a MRI sequence are substantially smaller than those based on CT, and the PTV-MRI volumes, defined by the union of T1, T2, STIR, and DCE, were comparable with those of PTV-CT for most of the cases studied.« less

  16. Monte Carlo simulations of adult and pediatric computed tomography exams: Validation studies of organ doses with physical phantoms

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Long, Daniel J.; Lee, Choonsik; Tien, Christopher

    2013-01-15

    Purpose: To validate the accuracy of a Monte Carlo source model of the Siemens SOMATOM Sensation 16 CT scanner using organ doses measured in physical anthropomorphic phantoms. Methods: The x-ray output of the Siemens SOMATOM Sensation 16 multidetector CT scanner was simulated within the Monte Carlo radiation transport code, MCNPX version 2.6. The resulting source model was able to perform various simulated axial and helical computed tomographic (CT) scans of varying scan parameters, including beam energy, filtration, pitch, and beam collimation. Two custom-built anthropomorphic phantoms were used to take dose measurements on the CT scanner: an adult male and amore » 9-month-old. The adult male is a physical replica of University of Florida reference adult male hybrid computational phantom, while the 9-month-old is a replica of University of Florida Series B 9-month-old voxel computational phantom. Each phantom underwent a series of axial and helical CT scans, during which organ doses were measured using fiber-optic coupled plastic scintillator dosimeters developed at University of Florida. The physical setup was reproduced and simulated in MCNPX using the CT source model and the computational phantoms upon which the anthropomorphic phantoms were constructed. Average organ doses were then calculated based upon these MCNPX results. Results: For all CT scans, good agreement was seen between measured and simulated organ doses. For the adult male, the percent differences were within 16% for axial scans, and within 18% for helical scans. For the 9-month-old, the percent differences were all within 15% for both the axial and helical scans. These results are comparable to previously published validation studies using GE scanners and commercially available anthropomorphic phantoms. Conclusions: Overall results of this study show that the Monte Carlo source model can be used to accurately and reliably calculate organ doses for patients undergoing a variety of axial or helical CT examinations on the Siemens SOMATOM Sensation 16 scanner.« less

  17. Role of preoperative 3-dimensional computed tomography reconstruction in depressed skull fractures treated with craniectomy: a case report of forensic interest.

    PubMed

    Viel, Guido; Cecchetto, Giovanni; Manara, Renzo; Cecchetto, Attilio; Montisci, Massimo

    2011-06-01

    Patients affected by cranial trauma with depressed skull fractures and increased intracranial pressure generally undergo neurosurgical intervention. Because craniotomy and craniectomy remove skull fragments and generate new fracture lines, they complicate forensic examination and sometimes prevent a clear identification of skull fracture etiology. A 3-dimensional reconstruction based on preoperative computed tomography (CT) scans, giving a picture of the injuries before surgical intervention, can help the forensic examiner in identifying skull fracture origin and the means of production.We report the case of a 41-year-old-man presenting at the emergency department with a depressed skull fracture at the vertex and bilateral subdural hemorrhage. The patient underwent 2 neurosurgical interventions (craniotomy and craniectomy) but died after 40 days of hospitalization in an intensive care unit. At autopsy, the absence of various bone fragments did not allow us to establish if the skull had been stricken by a blunt object or had hit the ground with high kinetic energy. To analyze bone injuries before craniectomy, a 3-dimensional CT reconstruction based on preoperative scans was performed. A comparative analysis between autoptic and radiological data allowed us to differentiate surgical from traumatic injuries. Moreover, based on the shape and size of the depressed skull fracture (measured from the CT reformations), we inferred that the man had been stricken by a cylindric blunt object with a diameter of about 3 cm.

  18. Value of a step-up diagnosis plan: CRP and CT-scan to diagnose and manage postoperative complications after major abdominal surgery.

    PubMed

    Straatman, Jennifer; Cuesta, Miguel A; Gisbertz, Suzanne S; Van der Peet, Donald L

    2014-12-01

    Postoperative complications frequently follow major abdominal surgery and are associated with increased morbidity and mortality. Early diagnosis and treatment of complications is associated with improved patient outcome. In this study we assessed the value of a step-up diagnosis plan by C-reactive protein and CT-scan (computed tomography-scan) imaging for detection of postoperative complications following major abdominal surgery.An observational cohort study was conducted of 399 consecutivepatients undergoing major abdominal surgery between January 2009 and January 2011. Indication for operation, type of surgery, postoperative morbidity, complications according to the Clavien-Dindo classification and mortality were recorded. Clinical parameters were recorded until 14 days postoperatively or until discharge. Regular C-reactive protein (CPR) measurements in peripheral blood and on indication -enhanced CT-scans were performed.Eighty-three out of 399 (20.6 %) patients developed a major complication in the postoperative course after a median of seven days (IQR 4-9 days). One hundred and thirty two patients received additional examination consisting of enhanced CT-scan imaging, and treatment by surgical reintervention or intensive care observation. CRP levels were significantly higher in patients with postoperative complications. On the second postoperative dayCRP levels were on average 197.4 mg/L in the uncomplicated group, 220.9 mg/L in patients with a minor complication and 280.1 mg/L in patients with major complications (p < 0,001).CT-scan imaging showed a sensitivity of 91.7 % and specificity of 100 % in diagnosis of major complications. Based on clinical deterioration and the increase of CRP, an additional enhanced CT-scan offered clear discrimination between patients with major abdominal complications and uncomplicated patients. Adequate treatment could then be accomplished.

  19. Barium enema and CT volumetry for predicting pathologic response to preoperative chemoradiotherapy in rectal cancer patients.

    PubMed

    Murono, Koji; Kawai, Kazushige; Tsuno, Nelson H; Ishihara, Soichiro; Yamaguchi, Hironori; Sunami, Eiji; Kitayama, Joji; Watanabe, Toshiaki

    2014-06-01

    Preoperative chemoradiotherapy has been widely used for the prevention of local recurrence of locally advanced rectal cancer, and the effect of chemoradiotherapy is known to be associated with overall survival. We aimed to evaluate the association of the pathologic response grade with tumor recurrence rate after chemoradiotherapy, using radiographic analysis and the Response Evaluation Criteria in Solid Tumors as the parameters. This study was conducted at a single tertiary care institution in Japan. This was a retrospective cohort study of patients undergoing preoperative chemoradiotherapy. A total of 101 low rectal cancer patients receiving preoperative chemoradiotherapy from July 2004 to August 2012 were enrolled. The tumor reduction rate was measured with the use of traditional Response Evaluation Criteria in Solid Tumors, barium enema, and CT volumetry, and the correlation between the reduction rate and the pathologic response grade was examined. The tumor reduction rate assessed according to Response Evaluation Criteria in Solid Tumors showed no association with the pathologic response grade (p =0.61). In contrast, the radiographic response rate by both barium enema and CT volumetry strongly correlated with the pathologic response grade (p < 0.0001 and p = 0.001).In terms of local tumor recurrence, those diagnosed as high responders by the pathologic response grade, Response Evaluation Criteria in Solid Tumors, barium enema, and CT volumetry had a lower recurrence rate (p =0.03, p =0.03, p =0.0002, and p =0.001). The difference between high responders and low responders was especially prominent by barium enema and CT volumetry. The study is limited by its retrospective nature. Double-contrast barium enema and CT volumetry were superior to Response Evaluation Criteria in Solid Tumors in evaluating the effect of chemoradiotherapy and predicting the likelihood of tumor recurrence.

  20. Incidental detection of colorectal lesions by FDG PET/CT scans in melanoma patients.

    PubMed

    Young, Christopher J; Zahid, Assad; Choy, Ian; Thompson, John F; Saw, Robyn P M

    2017-11-01

    Increased use of PET/CT scans in oncology patients has raised detection of Colorectal incidentalomas (CIs). The frequency and diagnostic outcomes of identifying these lesions in melanoma patients have not previously been studied. This studies primary objective was to determine the prevalence of CIs found on PET/CT scans in melanoma patients. The secondary objectives were to correlate the PET/CT findings with the pathology found at colonoscopy, and identify which patients were referred for colonoscopy. A retrospective analysis of patients identified from the prospectively collected research database of Melanoma Institute Australia. 2509 patients with melanoma underwent PET/CT scans between 2001 and 2013. The prevalence of CIs, the correlation of lesions, and the survival of patients who underwent colonoscopy versus patients who did not were analyzed. The prevalence of CIs in melanoma patients who had PET/CT scans was 3.2%. Forty-five of the 81 (56%) patients with CIs underwent colonoscopy. Of these, premalignant or malignant disease was found in 58%. Patients with previous metastatic melanoma were significantly less likely to be referred for colonoscopy. Patients undergoing colonoscopy had significantly better survival, as did those without previous distant metastases before the CIs were found, and those without any metastases at the time the CIs were found. These factors were not significant on multivariate analysis. The prevalence of incidental colorectal lesions identified on PET/CT scans in melanoma patients was found to be equivalent to that in the general cancer population. Patients undergoing colonoscopy had better survival than those who did not. Copyright © 2017 Elsevier Ltd, BASO ~ The Association for Cancer Surgery, and the European Society of Surgical Oncology. All rights reserved.

  1. PET-CT in oncological patients: analysis of informal care costs in cost-benefit assessment.

    PubMed

    Orlacchio, Antonio; Ciarrapico, Anna Micaela; Schillaci, Orazio; Chegai, Fabrizio; Tosti, Daniela; D'Alba, Fabrizio; Guazzaroni, Manlio; Simonetti, Giovanni

    2014-04-01

    The authors analysed the impact of nonmedical costs (travel, loss of productivity) in an economic analysis of PET-CT (positron-emission tomography-computed tomography) performed with standard contrast-enhanced CT protocols (CECT). From October to November 2009, a total of 100 patients referred to our institute were administered a questionnaire to evaluate the nonmedical costs of PET-CT. In addition, the medical costs (equipment maintenance and depreciation, consumables and staff) related to PET-CT performed with CECT and PET-CT with low-dose nonenhanced CT and separate CECT were also estimated. The medical costs were 919.3 euro for PET-CT with separate CECT, and 801.3 euro for PET-CT with CECT. Therefore, savings of approximately 13% are possible. Moreover, savings in nonmedical costs can be achieved by reducing the number of hospital visits required by patients undergoing diagnostic imaging. Nonmedical costs heavily affect patients' finances as well as having an indirect impact on national health expenditure. Our results show that PET-CT performed with standard dose CECT in a single session provides benefits in terms of both medical and nonmedical costs.

  2. Patients with Testicular Cancer Undergoing CT Surveillance Demonstrate a Pitfall of Radiation-induced Cancer Risk Estimates: The Timing Paradox

    PubMed Central

    Eisenberg, Jonathan D.; Lee, Richard J.; Gilmore, Michael E.; Turan, Ekin A.; Singh, Sarabjeet; Kalra, Mannudeep K.; Liu, Bob; Kong, Chung Yin; Gazelle, G. Scott

    2013-01-01

    Purpose: To demonstrate a limitation of lifetime radiation-induced cancer risk metrics in the setting of testicular cancer surveillance—in particular, their failure to capture the delayed timing of radiation-induced cancers over the course of a patient’s lifetime. Materials and Methods: Institutional review board approval was obtained for the use of computed tomographic (CT) dosimetry data in this study. Informed consent was waived. This study was HIPAA compliant. A Markov model was developed to project outcomes in patients with testicular cancer who were undergoing CT surveillance in the decade after orchiectomy. To quantify effects of early versus delayed risks, life expectancy losses and lifetime mortality risks due to testicular cancer were compared with life expectancy losses and lifetime mortality risks due to radiation-induced cancers from CT. Projections of life expectancy loss, unlike lifetime risk estimates, account for the timing of risks over the course of a lifetime, which enabled evaluation of the described limitation of lifetime risk estimates. Markov chain Monte Carlo methods were used to estimate the uncertainty of the results. Results: As an example of evidence yielded, 33-year-old men with stage I seminoma who were undergoing CT surveillance were projected to incur a slightly higher lifetime mortality risk from testicular cancer (598 per 100 000; 95% uncertainty interval [UI]: 302, 894) than from radiation-induced cancers (505 per 100 000; 95% UI: 280, 730). However, life expectancy loss attributable to testicular cancer (83 days; 95% UI: 42, 124) was more than three times greater than life expectancy loss attributable to radiation-induced cancers (24 days; 95% UI: 13, 35). Trends were consistent across modeled scenarios. Conclusion: Lifetime radiation risk estimates, when used for decision making, may overemphasize radiation-induced cancer risks relative to short-term health risks. © RSNA, 2012 Supplemental material: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.12121015/-/DC1 PMID:23249573

  3. Risk factors and the preoperative assessment of right para-oesophageal lymph node metastasis in right lobe papillary thyroid carcinoma: A case series.

    PubMed

    Qu, You; Zhang, Hao; Zhang, Ping; Dong, Wenwu; He, Liang; Sun, Wei; Liu, Jinhao

    2017-06-01

    Right para-oesophageal lymph nodes (RPELN) are included among the right central compartment lymph nodes (rCLN) and located behind right recurrent laryngeal nerve (rRLN). However, due to the likelihood of increasing postoperative complications, and the extremely difficulties of RPELN dissection, the decision to perform RPELN dissection remains controversial. The aim of this study was to explore the risk factors of RPELN metastasis and evaluate RPELN metastasis by preoperative examination. We reviewed the medical records of 163 consecutive papillary thyroid carcinoma (PTC) patients (125 females and 38 males) who underwent right lobe plus isthmic resection (91 patients) or total thyroidectomy (72 patients) with right or bilateral central compartment lymph node dissection. The RPELN dissections were performed in all patients and were individually dissected and recorded intraoperatively. All patients underwent thyroid ultrasound and enhanced neck computed tomography (CT) routinely during preoperative examination. RPELN metastasis was detected in 20 patients (12.3%), among whom 6 (3.7%) had RPELN metastasis without rCLN metastasis. Total rCLN metastasis and lateral compartment lymph node metastasis were confirmed in 57 (35.0%) and 24 (14.7%) patients, respectively. The tumour diameter, number of metastatic rCLN and lateral compartment lymph nodes, RPELN visible on CT, and enhanced CT value of RPELN were confirmed significantly associated with RPELN metastasis by univariate analysis (P < 0.05). The area under the ROC curve of CT values was 0.77 (95% CI, 0.59-0.95; P = 0.003). The CT value of 132.0 was used as the cut-off point, and the specificity and sensitivity were 84.1% and 71.4%, respectively. PTC patients with a large tumour (>1 cm) in the right lobe or suspected rCLN metastasis were recommended to undergo prophylactic RPELN dissection, particularly in those with a high enhanced CT value (>132) of RPELN or those with the copresence of lateral compartment lymph node metastasis. Copyright © 2017 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  4. SU-E-I-32: Benchmarking Head CT Doses: A Pooled Vs. Protocol Specific Analysis of Radiation Doses in Adult Head CT Examinations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fujii, K; UCLA School of Medicine, Los Angeles, CA; Bostani, M

    Purpose: The aim of this study was to collect CT dose index data from adult head exams to establish benchmarks based on either: (a) values pooled from all head exams or (b) values for specific protocols. One part of this was to investigate differences in scan frequency and CT dose index data for inpatients versus outpatients. Methods: We collected CT dose index data (CTDIvol) from adult head CT examinations performed at our medical facilities from Jan 1st to Dec 31th, 2014. Four of these scanners were used for inpatients, the other five were used for outpatients. All scanners used Tubemore » Current Modulation. We used X-ray dose management software to mine dose index data and evaluate CTDIvol for 15807 inpatients and 4263 outpatients undergoing Routine Brain, Sinus, Facial/Mandible, Temporal Bone, CTA Brain and CTA Brain-Neck protocols, and combined across all protocols. Results: For inpatients, Routine Brain series represented 84% of total scans performed. For outpatients, Sinus scans represented the largest fraction (36%). The CTDIvol (mean ± SD) across all head protocols was 39 ± 30 mGy (min-max: 3.3–540 mGy). The CTDIvol for Routine Brain was 51 ± 6.2 mGy (min-max: 36–84 mGy). The values for Sinus were 24 ± 3.2 mGy (min-max: 13–44 mGy) and for Facial/Mandible were 22 ± 4.3 mGy (min-max: 14–46 mGy). The mean CTDIvol for inpatients and outpatients was similar across protocols with one exception (CTA Brain-Neck). Conclusion: There is substantial dose variation when results from all protocols are pooled together; this is primarily a function of the differences in technical factors of the protocols themselves. When protocols are analyzed separately, there is much less variability. While analyzing pooled data affords some utility, reviewing protocols segregated by clinical indication provides greater opportunity for optimization and establishing useful benchmarks.« less

  5. SU-F-P-45: Clinical Experience with Radiation Dose Reduction of CT Examinations Using Iterative Reconstruction Algorithms

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weir, V; Zhang, J

    2016-06-15

    Purpose: Iterative reconstruction (IR) algorithms have been adopted by medical centers in the past several years. IR has a potential to substantially reduce patient dose while maintaining or improving image quality. This study characterizes dose reductions in clinical settings for CT examinations using IR. Methods: We retrospectively analyzed dose information from patients who underwent abdomen/pelvis CT examinations with and without contrast media in multiple locations of our Healthcare system. A total of 743 patients scanned with ASIR on 64 slice GE lightspeed VCTs at three sites, and 30 patients scanned with SAFIRE on a Siemens 128 slice Definition Flash inmore » one site was retrieved. For comparison, patient data (n=291) from a GE scanner and patient data (n=61) from two Siemens scanners where filtered back-projection (FBP) was used was collected retrospectively. 30% and 10% ASIR, and SAFIRE Level 2 was used. CTDIvol, Dose-length-product (DLP), weight and height from all patients was recorded. Body mass index (BMI) was calculated accordingly. To convert CTDIvol to SSDE, AP and lateral dimensions at the mid-liver level was measured for each patient. Results: Compared with FBP, 30% ASIR reduces dose by 44.1% (SSDE: 12.19mGy vs. 21.83mGy), while 10% ASIR reduced dose by 20.6% (SSDE 17.32mGy vs. 21.83). Use of SAFIRE reduced dose by 61.4% (SSDE: 8.77mGy vs. 22.7mGy). The geometric mean for patients scanned with ASIR was larger than for patients scanned with FBP (geometric mean is 297.48 mmm vs. 284.76 mm). The same trend was observed for the Siemens scanner where SAFIRE was used (geometric mean: 316 mm with SAFIRE vs. 239 mm with FBP). Patient size differences suggest that further dose reduction is possible. Conclusion: Our data confirmed that in clinical practice IR can significantly reduce dose to patients who undergo CT examinations, while meeting diagnostic requirements for image quality.« less

  6. Is Ultrasound a Valid and Reliable Imaging Modality for Airway Evaluation?: An Observational Computed Tomographic Validation Study Using Submandibular Scanning of the Mouth and Oropharynx.

    PubMed

    Abdallah, Faraj W; Yu, Eugene; Cholvisudhi, Phantila; Niazi, Ahtsham U; Chin, Ki J; Abbas, Sherif; Chan, Vincent W

    2017-01-01

    Ultrasound (US) imaging of the airway may be useful in predicting difficulty of airway management (DAM); but its use is limited by lack of proof of its validity and reliability. We sought to validate US imaging of the airway by comparison to CT-scan, and to assess its inter- and intra-observer reliability. We used submandibular sonographic imaging of the mouth and oropharynx to examine how well the ratio of tongue thickness to oral cavity height correlates with the ratio of tongue volume to oral cavity volume, an established tomographic measure of DAM. A cohort of 34 patients undergoing CT-scan was recruited. Study standardized assessments included CT-measured ratios of tongue volume to oropharyngeal cavity volume; tongue thickness to oral cavity height; and US-measured ratio of tongue thickness to oral cavity height. Two sonographers independently performed US imaging of the airway before and after CT-scan. Our findings indicate that the US-measured ratio of tongue thickness to oral cavity height highly correlates with the CT-measured ratio of tongue volume to oral cavity volume. US measurements also demonstrated strong inter- and intra-observer reliability. This study suggests that US is a valid and reliable tool for imaging the oral and oropharyngeal parts of the airway, as well as for measuring the volumetric relationship between the tongue and oral cavity, and may therefore be a useful predictor of DAM. © 2016 by the American Institute of Ultrasound in Medicine.

  7. VirtualDose: a software for reporting organ doses from CT for adult and pediatric patients.

    PubMed

    Ding, Aiping; Gao, Yiming; Liu, Haikuan; Caracappa, Peter F; Long, Daniel J; Bolch, Wesley E; Liu, Bob; Xu, X George

    2015-07-21

    This paper describes the development and testing of VirtualDose--a software for reporting organ doses for adult and pediatric patients who undergo x-ray computed tomography (CT) examinations. The software is based on a comprehensive database of organ doses derived from Monte Carlo (MC) simulations involving a library of 25 anatomically realistic phantoms that represent patients of different ages, body sizes, body masses, and pregnant stages. Models of GE Lightspeed Pro 16 and Siemens SOMATOM Sensation 16 scanners were carefully validated for use in MC dose calculations. The software framework is designed with the 'software as a service (SaaS)' delivery concept under which multiple clients can access the web-based interface simultaneously from any computer without having to install software locally. The RESTful web service API also allows a third-party picture archiving and communication system software package to seamlessly integrate with VirtualDose's functions. Software testing showed that VirtualDose was compatible with numerous operating systems including Windows, Linux, Apple OS X, and mobile and portable devices. The organ doses from VirtualDose were compared against those reported by CT-Expo and ImPACT-two dosimetry tools that were based on the stylized pediatric and adult patient models that were known to be anatomically simple. The organ doses reported by VirtualDose differed from those reported by CT-Expo and ImPACT by as much as 300% in some of the patient models. These results confirm the conclusion from past studies that differences in anatomical realism offered by stylized and voxel phantoms have caused significant discrepancies in CT dose estimations.

  8. Assessment of Osteoporosis in Injured Older Women Admitted to a Safety-Net Level One Trauma Center: A Unique Opportunity to Fulfill an Unmet Need

    PubMed Central

    Young, Elisabeth S.; Reed, May J.; Pham, Tam N.; Gross, Joel A.; Taitsman, Lisa A.

    2017-01-01

    Background Older trauma patients often undergo computed tomography (CT) as part of the initial work-up. CT imaging can also be used opportunistically to measure bone density and assess osteoporosis. Methods In this retrospective cohort study, osteoporosis was ascertained from admission CT scans in women aged ≥65 admitted to the ICU for traumatic injury during a 3-year period at a single, safety-net, level 1 trauma center. Osteoporosis was defined by established CT-based criteria of average L1 vertebral body Hounsfield units <110. Evidence of diagnosis and/or treatment of osteoporosis was the primary outcome. Results The study cohort consisted of 215 women over a 3-year study period, of which 101 (47%) had evidence of osteoporosis by CT scan criteria. There were no differences in injury severity score, hospital length of stay, cost, or discharge disposition between groups with and without evidence of osteoporosis. Only 55 (59%) of the 94 patients with osteoporosis who survived to discharge had a documented osteoporosis diagnosis and/or corresponding evaluation/treatment plan. Conclusion Nearly half of older women admitted with traumatic injuries had underlying osteoporosis, but 41% had neither clinical recognition of this finding nor a treatment plan for osteoporosis. Admission for traumatic injury is an opportunity to assess osteoporosis, initiate appropriate intervention, and coordinate follow-up care. Trauma and acute care teams should consider assessment of osteoporosis in women who undergo CT imaging and provide a bridge to outpatient services. PMID:29234352

  9. Fracture Prediction by Computed Tomography and Finite Element Analysis: Current and Future Perspectives.

    PubMed

    Johannesdottir, Fjola; Allaire, Brett; Bouxsein, Mary L

    2018-05-30

    This review critiques the ability of CT-based methods to predict incident hip and vertebral fractures. CT-based techniques with concurrent calibration all show strong associations with incident hip and vertebral fracture, predicting hip and vertebral fractures as well as, and sometimes better than, dual-energy X-ray absorptiometry areal biomass density (DXA aBMD). There is growing evidence for use of routine CT scans for bone health assessment. CT-based techniques provide a robust approach for osteoporosis diagnosis and fracture prediction. It remains to be seen if further technical advances will improve fracture prediction compared to DXA aBMD. Future work should include more standardization in CT analyses, establishment of treatment intervention thresholds, and more studies to determine whether routine CT scans can be efficiently used to expand the number of individuals who undergo evaluation for fracture risk.

  10. Recurrent malignant pheochromocytoma with unusual omental metastasis: 68Ga-DOTANOC PET/CT and 131I-MIBG SPECT/CT scintigraphy findings

    PubMed Central

    Arora, Saurabh; Agarwal, Krishan Kant; Karunanithi, Sellam; Tripathi, Madhavi; Kumar, Rakesh

    2014-01-01

    Pheochromocytomas are rare catecholamine-secreting tumors derived from the sympathetic nervous system. The most common sites of metastasis for pheochromocytoma or extra-adrenal paraganglioma are lymph nodes, bones, lungs, and liver. Patients with known or suspected malignancy should undergo staging with computed tomography (CT) or magnetic resonance imaging as well as functional imaging (e.g. with 123I/131I-MIBG (131I-metaiodobenzylguanidine) and 68Ga-DOTANOC (68Ga-labeled [1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid]-1-NaI3-octreotide) positron emission tomography (PET)/CT) to determine the extent and location of disease. We present a case of recurrent malignant pheochromocytoma with unusual site of metastasis in omentum, which was positive on 68Ga-DOTANOC PET/CT and 131I-MIBG single-photon emission computed tomography (SPECT/)/CT scintigraphy. PMID:25400380

  11. Recurrent malignant pheochromocytoma with unusual omental metastasis: (68)Ga-DOTANOC PET/CT and (131)I-MIBG SPECT/CT scintigraphy findings.

    PubMed

    Arora, Saurabh; Agarwal, Krishan Kant; Karunanithi, Sellam; Tripathi, Madhavi; Kumar, Rakesh

    2014-10-01

    Pheochromocytomas are rare catecholamine-secreting tumors derived from the sympathetic nervous system. The most common sites of metastasis for pheochromocytoma or extra-adrenal paraganglioma are lymph nodes, bones, lungs, and liver. Patients with known or suspected malignancy should undergo staging with computed tomography (CT) or magnetic resonance imaging as well as functional imaging (e.g. with (123)I/(131)I-MIBG ((131)I-metaiodobenzylguanidine) and (68)Ga-DOTANOC ((68)Ga-labeled [1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid]-1-NaI3-octreotide) positron emission tomography (PET)/CT) to determine the extent and location of disease. We present a case of recurrent malignant pheochromocytoma with unusual site of metastasis in omentum, which was positive on (68)Ga-DOTANOC PET/CT and (131)I-MIBG single-photon emission computed tomography (SPECT/)/CT scintigraphy.

  12. [18F-Fluorocholine PET-CT for localization of parathyroid adenomas].

    PubMed

    Kluijfhout, Wouter P; Vriens, Menno R; Borel Rinkes, Inne H M; Valk, Gerlof D; de Klerk, John M H; de Keizer, Bart

    2015-01-01

    18F-fluorocholine PET-CT is a new imaging modality for the localization of pathological parathyroid glands in patients with primary hyperparathyroidism. The PET-CT is a combination scan that uses both the physiological information from the PET and the anatomical information from the CT. Uptake of the radio-isotope 18F-fluorocholine is increased in pathological parathyroid glands. 18F-fluorocholine PET-CT helps clinicians to localize the pathological parathyroid glands where conventional modalities fail to do so. This enables surgeons to carry out targeted minimal invasive surgery. It may also prevent the patient having to undergo a more extensive exploration, with its associated risks, and alleviate the necessity of taking medications with side effects. Although the literature on this subject is still scarce, preliminary results are promising. As any hospital with a PET-CT can perform the scan, we expect that its use in patients with hyperparathyroidism will increase over the next few years.

  13. Dyspnea predicts mortality among patients undergoing coronary computed tomographic angiography.

    PubMed

    Nakanishi, Rine; Gransar, Heidi; Rozanski, Alan; Rana, Jamal S; Cheng, Victor Y; Thomson, Louise E J; Miranda-Peats, Romalisa; Dey, Damini; Hayes, Sean W; Friedman, John D; Min, James K; Berman, Daniel S

    2016-02-01

    The prognostic implications of dyspnea and typical angina in patients referred for coronary CT angiography have not been examined. We examined features associated with incident mortality risk among individuals undergoing coronary computed tomographic angiography (CCTA) presenting with dyspnea, typical angina, and neither of these symptoms. 1147 consecutive individuals without known CAD (mean 61 years, 61.6 %men) undergoing CCTA comprised the study population 132 with dyspnea, 218 with typical angina, and 797 without dyspnea or typical angina (reference group). Mortality risk in relation to dyspnea or typical angina was evaluated with multivariable Cox proportional hazards models compared to reference. In addition, the prognosis associated with dyspnea or typical angina was assessed among age matched subgroups. Patients with dyspnea had a greater prevalence of C70 % stenosis (p\\0.001) and coronary segments with plaque (p = 0.02) compared to the other two groups. During a follow-up of 3.1 years, 52 individuals died. By multivariable Cox models, compared to patients in reference group, dyspnea patients experienced higher mortality (HR 2.0, 95 % CI 1.0–4.0, p = 0.049) while typical angina patients did not (HR 1.1, 95 % CI 0.6–2.3, p = 0.76). In the matched group, the patients with dyspnea (HR 2.2, 95 % CI 1.1–4.3, p = 0.03) still had significantly reduced survival compared to the other two groups, while those with typical angina did not (HR 1.2, 95 % CI 0.6–2.6,p = 0.62). Dyspnea is associated with increased mortality ate compared to patients with typical angina and those with neither of these symptoms among patients undergoing CCTA.

  14. Hospital of diagnosis and probability of having surgical treatment for resectable gastric cancer.

    PubMed

    van Putten, M; Verhoeven, R H A; van Sandick, J W; Plukker, J T M; Lemmens, V E P P; Wijnhoven, B P L; Nieuwenhuijzen, G A P

    2016-02-01

    Gastric cancer surgery is increasingly being centralized in the Netherlands, whereas the diagnosis is often made in hospitals where gastric cancer surgery is not performed. The aim of this study was to assess whether hospital of diagnosis affects the probability of undergoing surgery and its impact on overall survival. All patients with potentially curable gastric cancer according to stage (cT1/1b-4a, cN0-2, cM0) diagnosed between 2005 and 2013 were selected from The Netherlands Cancer Registry. Multilevel logistic regression was used to examine the probability of undergoing surgery according to hospital of diagnosis. The effect of variation in probability of undergoing surgery among hospitals of diagnosis on overall survival during the intervals 2005-2009 and 2010-2013 was examined by using Cox regression analysis. A total of 5620 patients with potentially curable gastric cancer, diagnosed in 91 hospitals, were included. The proportion of patients who underwent surgery ranged from 53.1 to 83.9 per cent according to hospital of diagnosis (P < 0.001); after multivariable adjustment for patient and tumour characteristics it ranged from 57.0 to 78.2 per cent (P < 0.001). Multivariable Cox regression showed that patients diagnosed between 2010 and 2013 in hospitals with a low probability of patients undergoing curative treatment had worse overall survival (hazard ratio 1.21; P < 0.001). The large variation in probability of receiving surgery for gastric cancer between hospitals of diagnosis and its impact on overall survival indicates that gastric cancer decision-making is suboptimal. © 2015 BJS Society Ltd Published by John Wiley & Sons Ltd.

  15. Commissioning and Characterization of a Dedicated High-Resolution Breast PET Camera

    DTIC Science & Technology

    2014-02-01

    aim to achieve 1 mm3 resolution using a unique detector design that is able to measure annihilation radiation coming from the PET tracer in 3...undergoing a regular staging PET /CT. We will image with the novel two-panel system after the standard PET /CT scan , in order not to interfere with the...Resolution Breast PET Camera PRINCIPAL INVESTIGATOR: Arne Vandenbroucke, Ph.D. CONTRACTING ORGANIZATION: Stanford University

  16. A Multidisciplinary Evaluation of Traumatic Brain Injury: Early Predictors of Outcome

    DTIC Science & Technology

    2007-04-01

    undergoing an acceleration/deceleration movement (i.e., whiplash ) without direct external trauma to the head . Computed tomography (CT...mild head injury. J Neurol Neurosurg Psychiatry. 1985;48:137-140. Geurts ACH , Ribbers GM, Knoop JA, van Limbeek J. Identification of static and...boney) Injury 30 Facial Injury 13 Skull Fracture/ Head CT Findings 7 Symptoms (i.e. dizziness, nausea, vomiting) 10 Past Medical History 6 The NBM

  17. CT scan exposure in Spanish children and young adults by socioeconomic status: Cross-sectional analysis of cohort data.

    PubMed

    Bosch de Basea, Magda; Espinosa, Ana; Gil, Mariona; Figuerola, Jordi; Pardina, Marina; Vilar, José; Cardis, Elisabeth

    2018-01-01

    Recent publications reported that children in disadvantaged areas undergo more CT scanning than others. The present study is aimed to assess the potential differences in CT imaging by socioeconomic status (SES) in Spanish young scanned subjects and if such differences vary with different indicators or different time point SES measurements. The associations between CT scanning and SES, and between the CT scan rate per patient and SES were investigated in the Spanish EPI-CT subcohort. Various SES indicators were studied to determine whether particular SES dimensions were more closely related to the probability of undergoing one or multiple CTs. Comparisons were made with indices based on 2001 and 2011 censuses. We found evidence of socio-economic variation among young people, mainly related to autonomous communities of residence. A slightly higher rate of scans per patient of multiple body parts in the less affluent categories was observed, possibly reflecting a higher rate of accidents and violence in these groups. The number of CT scans per patient was higher both in the most affluent and the most deprived categories and somewhat lower in the intermediate groups. This relation varied with the SES indicator used, with lower CT scans per patients in categories of high unemployment and temporary work, but not depending on categories of unskilled work or illiteracy. The relationship between these indicators and number of CTs in 2011 was different than that seen with the 2001 census, with the number of CTs increasing with higher unemployment. Overall we observed some differences in the SES distribution of scanned patients by Autonomous Community in Spain. There was, however, no major differences in the frequency of CT scans per patient by SES overall, based on the 2001 census. The use of different indicators and of SES data collected at different time points led to different relations between SES and frequency of CT scans, outlining the difficulty of adequately capturing the social and economic dimensions which may affect health and health service utilisation.

  18. CT scan exposure in Spanish children and young adults by socioeconomic status: Cross-sectional analysis of cohort data

    PubMed Central

    Espinosa, Ana; Gil, Mariona; Figuerola, Jordi; Pardina, Marina; Vilar, José; Cardis, Elisabeth

    2018-01-01

    Recent publications reported that children in disadvantaged areas undergo more CT scanning than others. The present study is aimed to assess the potential differences in CT imaging by socioeconomic status (SES) in Spanish young scanned subjects and if such differences vary with different indicators or different time point SES measurements. The associations between CT scanning and SES, and between the CT scan rate per patient and SES were investigated in the Spanish EPI-CT subcohort. Various SES indicators were studied to determine whether particular SES dimensions were more closely related to the probability of undergoing one or multiple CTs. Comparisons were made with indices based on 2001 and 2011 censuses. We found evidence of socio-economic variation among young people, mainly related to autonomous communities of residence. A slightly higher rate of scans per patient of multiple body parts in the less affluent categories was observed, possibly reflecting a higher rate of accidents and violence in these groups. The number of CT scans per patient was higher both in the most affluent and the most deprived categories and somewhat lower in the intermediate groups. This relation varied with the SES indicator used, with lower CT scans per patients in categories of high unemployment and temporary work, but not depending on categories of unskilled work or illiteracy. The relationship between these indicators and number of CTs in 2011 was different than that seen with the 2001 census, with the number of CTs increasing with higher unemployment. Overall we observed some differences in the SES distribution of scanned patients by Autonomous Community in Spain. There was, however, no major differences in the frequency of CT scans per patient by SES overall, based on the 2001 census. The use of different indicators and of SES data collected at different time points led to different relations between SES and frequency of CT scans, outlining the difficulty of adequately capturing the social and economic dimensions which may affect health and health service utilisation. PMID:29723272

  19. Technical note: estimating absorbed doses to the thyroid in CT.

    PubMed

    Huda, Walter; Magill, Dennise; Spampinato, Maria V

    2011-06-01

    To describe a method for estimating absorbed doses to the thyroid in patients undergoing neck CT examinations. Thyroid doses in anthropomorphic phantoms were obtained for all 23 scanner dosimetry data sets in the ImPACT CT patient dosimetry calculator. Values of relative thyroid dose [R(thy)(L)], defined as the thyroid dose for a given scan length (L) divided by the corresponding thyroid dose for a whole body scan, were determined for neck CT scans. Ratios of the maximum thyroid dose to the corresponding CTDI(vol) and [D'(thy)], were obtained for two phantom diameters. The mass-equivalent water cylinder of any patient can be derived from the neck cross-sectional area and the corresponding average Hounsfield Unit, and compared to the 16.5-cm diameter water cylinder that models the ImPACT anthropomorphic phantom neck. Published values of relative doses in water cylinders of varying diameter were used to adjust thyroid doses in the anthropomorphic phantom to those of any sized patient. Relative thyroid doses R(thy)(L) increase to unity with increasing scan length and with very small difference between scanners. A 10-cm scan centered on the thyroid would result in a dose that is, nearly 90% of the thyroid dose from a whole body scan when performed using the constant radiographic techniques. At 120 kV, the average value of D'(thy) for the 16-cm diameter was 1.17 +/- 0.05 and was independent of CT vendor and year of CT scanner, and choice of x-ray tube voltage. The corresponding average value of D'(thy) in the 32-cm diameter phantom was 2.28 +/- 0.22 and showed marked variations depending on vendor, year of introduction into clinical practice as well as x-ray tube voltage. At 120 kV, a neck equivalent to a 10-cm diameter cylinder of water would have thyroid doses 36% higher than those in the ImPACT phantom, whereas a neck equivalent to a 25-cm cylinder diameter would have thyroid doses 35% lower. Patient thyroid doses can be estimated by taking into account the amount of radiation used to perform the CT examination (CTDI(vol)) and accounting for scan length and patient anatomy (i.e., neck diameter) at the thyroid location.

  20. Sinusitis in patients undergoing allogeneic bone marrow transplantation - a review.

    PubMed

    Drozd-Sokolowska, Joanna Ewa; Sokolowski, Jacek; Wiktor-Jedrzejczak, Wieslaw; Niemczyk, Kazimierz

    Sinusitis is a common morbidity in general population, however little is known about its occurrence in severely immunocompromised patients undergoing allogeneic hematopoietic stem cell transplantation. The aim of the study was to analyze the literature concerning sinusitis in patients undergoing allogeneic bone marrow transplantation. An electronic database search was performed with the objective of identifying all original trials examining sinusitis in allogeneic hematopoietic stem cell transplant recipients. The search was limited to English-language publications. Twenty five studies, published between 1985 and 2015 were identified, none of them being a randomized clinical trial. They reported on 31-955 patients, discussing different issues i.e. value of pretransplant sinonasal evaluation and its impact on post-transplant morbidity and mortality, treatment, risk factors analysis. Results from analyzed studies yielded inconsistent results. Nevertheless, some recommendations for good practice could be made. First, it seems advisable to screen all patients undergoing allogeneic hematopoietic stem cell transplantation with Computed Tomography (CT) prior to procedure. Second, patients with symptoms of sinusitis should be treated before hematopoietic stem cell transplantation (HSCT), preferably with conservative medical approach. Third, patients who have undergone hematopoietic stem cell transplantation should be monitored closely for sinusitis, especially in the early period after transplantation. Copyright © 2016 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  1. Coronary risk stratification of patients undergoing surgery for valvular heart disease.

    PubMed

    Hasselbalch, Rasmus Bo; Engstrøm, Thomas; Pries-Heje, Mia; Heitmann, Merete; Pedersen, Frants; Schou, Morten; Mickley, Hans; Elming, Hanne; Steffensen, Rolf; Køber, Lars; Iversen, Kasper

    2017-01-15

    Multislice computed tomography (MSCT) is a non-invasive, less expensive, low-radiation alternative to coronary angiography (CAG) prior to valvular heart surgery. MSCT has a high negative predictive value for coronary artery disease (CAD) but previous studies of patients with valvular disease have shown that MSCT, as the primary evaluation technique, lead to re-evaluation with CAG in about a third of cases and it is therefore not recommended. If a subgroup of patients with low- to intermediate risk of CAD could be identified and examined with MSCT, it could be cost-effective, reduce radiation and the risk of complications associated with CAG. The study cohort was derived from a national registry of patients undergoing CAG prior to valvular heart surgery. Using logistic regression, we identified significant risk factors for CAD and developed a risk score (CT-valve score). The score was validated on a similar cohort of patients from another registry. The study cohort consisted of 2221 patients, 521 (23.5%) had CAD. The validation cohort consisted of 2575 patients, 771 (29.9%) had CAD. The identified risk factors were male sex, age, smoking, hyperlipidemia, hypertension, aortic valve disease, extracardiac arteriopathy, ejection fraction <30% and diabetes mellitus. CT-valve score could identify a third of the population with a risk about 10%. A score based on risk factors of CAD can identify patients that might benefit from using MSCT as a gatekeeper to CAG prior to heart valve surgery. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  2. Use of Video Goggles to Distract Patients During PET/CT Studies of School-Aged Children.

    PubMed

    Gelfand, Michael J; Harris, Jennifer M; Rich, Amanda C; Kist, Chelsea S

    2016-12-01

    This study was designed to evaluate the effectiveness of video goggles in distracting children undergoing PET/CT and to determine whether the goggles create CT and PET artifacts. Video goggles with small amounts of internal radioopaque material were used. During whole-body PET/CT imaging, 30 nonsedated patients aged 4-13 y watched videos of their choice using the goggles. Fifteen of the PET/CT studies were performed on a scanner installed in 2006, and the other 15 were performed on a scanner installed in 2013. The fused scans were reviewed for evidence of head movement, and the individual PET and CT scans of the head were reviewed for the presence and severity of streak artifact. The CT exposure settings were recorded for each scan at the anatomic level at which the goggles were worn. Only one of the 30 scans had evidence of significant head motion. Two of the 30 had minor coregistration problems due to motion, and 27 of the 30 had very good to excellent coregistration. For the 2006 scanner, 2 of the 14 evaluable localization CT scans of the head demonstrated no streak artifact in brain tissue, 6 of the 14 had mild streak artifact in brain tissue, and 6 of the 14 had moderate streak artifact in brain tissue. Mild streak artifact in bone was noted in 2 of the 14 studies. For the 2013 scanner, 7 of 15 studies had mild streak artifact in brain tissue and 8 of 15 had no streak artifact in brain tissue, whereas none of the 15 had streak artifact in bone. There were no artifacts attributable to the goggles on the 18 F-FDG PET brain images of any of the 29 evaluable studies. The average CT exposure parameters at the level of the orbits were 36% lower on the 2013 scanner than on the 2006 scanner. Video goggles may be used successfully to distract children undergoing PET with localization CT. The goggles cause no significant degradation of the PET brain images or the CT skull images. The degree of artifact on brain tissue images varies from none to moderate and depends on the CT equipment used. © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  3. CT analysis of lung density changes in patients undergoing total body irradiation prior to bone marrow transplantation.

    PubMed

    Lee, J Y; Shank, B; Bonfiglio, P; Reid, A

    1984-10-01

    Sequential changes in lung density measured by CT are potentially sensitive and convenient monitors of lung abnormalities following total body irradiation (TBI). Methods have been developed to compare pre- and post-TBI CT of lung. The average local features of a cross-sectional lung slice are extracted from three peripheral regions of interest in the anterior, posterior, and lateral portions of the CT image. Also, density profiles across a specific region may be obtained. These may be compared first for verification of patient position and breathing status and then for changes between pre- and post-TBI. These may also be compared with radiation dose profiles through the lung. A preliminary study on 21 leukemia patients undergoing total body irradiation indicates the following: (a) Density gradients of patients' lungs in the antero-posterior direction show a marked heterogeneity before and after transplantation compared with normal lungs. The patients with departures from normal density gradients pre-TBI correlate with later pulmonary complications. (b) Measurements of average peripheral lung densities have demonstrated that the average lung density in the younger age group is substantially higher: pre-TBI, the average CT number (1,000 scale) is -638 +/- 39 Hounsfield unit (HU) for 0-10 years old and -739 +/- 53 HU for 21-40 years old. (c) Density profiles showed no post-TBI regional changes in lung density corresponding to the dose profile across the lung, so no differentiation of a radiation-specific effect has yet been possible. Computed tomographic density profiles in the antero-posterior direction are successfully used to verify positioning of the CT slice and the breathing level of the lung.

  4. Quantitative evaluation of native lung hyperinflation after single lung transplantation for emphysema using three-dimensional computed tomography volumetry.

    PubMed

    Motoyama, H; Chen, F; Ohsumi, A; Hijiya, K; Takahashi, M; Ohata, K; Yamada, T; Sato, M; Aoyama, A; Bando, T; Date, H

    2014-04-01

    Although double lung transplantation is performed more frequently for emphysema, single lung transplantation (SLT) continues to be performed owing to limited donor organ availability. Native lung hyperinflation (NLH) is a unique complication following SLT for emphysema. Three-dimensional computed tomography (3D-CT) volumetry has been introduced into the field of lung transplantation, which we used to assess NLH in emphysema patients undergoing SLT. The primary purpose of this study was to confirm the effectiveness of 3D-CT volumetry in the evaluation of NLH following SLT for emphysema. In 5 emphysema patients undergoing SLT at Kyoto University Hospital, 3D-CT volumetry data, pulmonary function test results, and clinical and radiological findings were retrospectively evaluated. Three patients did not develop a significant mediastinal shift, whereas the other 2 patients developed a mediastinal shift. In the 3 patients without a mediastinal shift, 3D-CT volumetry did not show a significant increase in native lung volume. These patients had a history of sternotomy prior to lung transplantation and firm adhesion on the mediastinal side was detected during lung transplantation. One of 2 patients with a mediastinal shift developed severe dyspnea with significantly decreased pulmonary function, and 3D-CT volumetry showed a significant increase in the native lung volume. However, the other patient did not show any dyspnea and his native lung volume decreased postoperatively (preoperatively to 6 months postoperatively: +981 mL and -348 mL, respectively). Although bilateral lung transplantation has become preferable for emphysema patients owing to postoperative NLH with SLT, patients with a history of sternotomy prior to lung transplantation might be good candidates for SLT. 3D-CT volumetry may be a useful method for detection of NLH. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. Dual tracer functional imaging of gastroenteropancreatic neuroendocrine tumors using 68Ga-DOTA-NOC PET-CT and 18F-FDG PET-CT: competitive or complimentary?

    PubMed

    Naswa, Niraj; Sharma, Punit; Gupta, Santosh Kumar; Karunanithi, Sellam; Reddy, Rama Mohan; Patnecha, Manish; Lata, Sneh; Kumar, Rakesh; Malhotra, Arun; Bal, Chandrasekhar

    2014-01-01

    This study aimed to compare the diagnostic performance of Ga-DOTANOC PET/CT with F-FDG PET/CT in the patients with gastroenteropancreatic neuroendocrine tumors (GEP-NETs). Data of 51 patients with definite histological diagnosis of GEP-NET who underwent both Ga-DOTA-NOC PET-CT and F-FDG PET-CT within a span of 15 days were selected for this retrospective analysis. Sensitivity, specificity, and predictive values were calculated for Ga-DOTA-NOC PET-CT and F-FDG PET-CT, and results were compared both on patientwise and regionwise analysis. Ga-DOTA-NOC PET-CT is superior to F-FDG PET-CT on patientwise analysis (P < 0.0001). On regionwise analysis, Ga-DOTA-NOC PET-CT is superior to F-FDG PET-CT only for lymph node metastases (P < 0.003). Although Ga-DOTA-NOC PET-CT detected more liver and skeletal lesions compared with F-FDG PET-CT, the difference was not statistically significant. In addition, the results of combined imaging helped in selecting candidates who would undergo the appropriate mode of treatment, whether octreotide therapy or conventional chemotherapy Ga-DOTA-NOC PET-CT seems to be superior to F-FDG PET-CT for imaging GEP-NETs. However, their role seems to be complementary because combination of Ga-DOTA-NOC PET-CT and F-FDG PET-CT in such patients helps demonstrate the total disease burden and segregate them to proper therapeutic groups.

  6. Extravasation of contrast medium during CT examination: an observational case-control study.

    PubMed

    Alami, Zayneb; Nasri, Siham; Ahid, Samir; Kacem, Hanane Hadj

    2015-01-01

    Extravasation is an adverse reaction to intravenous injection of contrast medium (CM) during CT examination. The objectives of this study are to determine the frequency, management and outcomes of extravasations and to assess risk factors for extravasation. Every incident of extravasation which occurred between March 2012 and March 31, 2013 was recorded in an extravasation form. Ethics Committee approval was obtained and the patients gave their consent to participate in the study. Data collected in the form included patients' age, sex, comorbidities, symptoms, CM used, injection mode, site and rate, extravasated volume, location of extravasation, severity of injury, treatment and patient outcome. Each case was matched with 4 controls of the same age ± 5 years and the same gender when possible. Extravasation occurred in 18 (7 women, 11 men) out of 2,000 injections of CM (0.9%) with a median age of 53 (10-78) years. Automated injection was performed in all cases with a mean rate of 1.7 ml/s. Large extravasated volumes (≥50 ml) were more observed in patients undergoing CT angiography (28.6% vs. 6.6%, although not significant P=0.112). Multivariate analysis revealed a significant association between patients with cardiac diseases and extravasation (OR: 7.3, 95% CI (1.09-49.05), P=0.04) whereas the injection rate is a protective factor from extravasation (P=0.002). Extravasation of CM results in mild to moderate adverse effects in all cases. Our study suggests that patients with cardiac disease are more predisposed to contrast extravasation than others. Further and larger studies are needed to confirm this trend.

  7. Comparison of 68Ga-PSMA-11 PET-CT with mpMRI for preoperative lymph node staging in patients with intermediate to high-risk prostate cancer.

    PubMed

    Zhang, Qing; Zang, Shiming; Zhang, Chengwei; Fu, Yao; Lv, Xiaoyu; Zhang, Qinglei; Deng, Yongming; Zhang, Chuan; Luo, Rui; Zhao, Xiaozhi; Wang, Wei; Wang, Feng; Guo, Hongqian

    2017-11-07

    To evaluate the diagnostic value of 68 Ga-PSMA-11 PET-CT with multiparametric magnetic resonance imaging (mpMRI) for lymph node (LN) staging in patients with intermediate- to high-risk prostate cancer (PCa) undergoing radical prostatectomy (RP) with pelvic lymph node dissection (PLND). We retrospectively identified 42 consecutive patients with intermediate- to high-risk PCa according to D'Amico and without concomitant cancer. Preoperative 68 Ga-PSMA-11 PET-CT, pelvic mpMRI and subsequent robot assisted laparoscopic RP with PLND were performed in all patients. Among 42 patients assessed, the preoperative PSA value, Gleason score, pT stage and intraprostatic PCa volume of patients with LN metastases were all significantly higher than those without metastases (P = 0.029, 0.028, 0.004, respectively). The average maximum standardized uptake value (SUV) of 68 Ga-PSMA-11 PET-CT positive PCa of patients with or without LN metastases were 13.10 (range 6.12-51.75) and 7.22 (range 5.4-11.2), respectively (P < 0.001). 68 Ga-PSMA-11 PET-CT and pelvic mpMRI had the ability of succeed on preoperative definite accurate diagnosis and accurate localization of primary PCa in all 42 patients. Fifteen patients (35.71%) had a pN1 stage. 51 positive LN were found. Both 68 Ga-PSMA-11 PET-CT and pelvic mpMRI displayed brillient patient-based and region-based sensitivity, specificity, negative predictive value and positive predictive value. There was no statistical difference for the detection of LNMs according to the diameter of the LNMs between 68 Ga-PSMA-11 PET-CT and mpMRI in this study. Both 68 Ga-PSMA-11 PET-CT and mpMRI performed great value for LN staging in patients with intermediate- to high-risk PCa undergoing RP with PLND. However, despite excellent performance of 68 Ga-PSMA-11 PET-CT, it cannot replace mpMRI that remains excellent for lymph node staging.

  8. Destructive granuloma derived from a liver cyst: A case report

    PubMed Central

    Kawashita, Yujo; Kamohara, Yukio; Furui, Junichiro; Fujita, Fumihiko; Miyamoto, Shungo; Takatsuki, Mitsuhisa; Abe, Kuniko; Hayashi, Tomayoshi; Ohno, Yasuharu; Kanematsu, Takashi

    2006-01-01

    We herein report the case of an idiopathic liver cystic mass which aggressively infiltrated the thoraco-abdominal wall. A 74-year-old woman who had a huge cystic lesion in her right hepatic lobe was transferred to our hospital for further examinations. Imaging studies revealed a simple liver cyst, and the cytological findings of intracystic fluid were negative. She was followed up periodically by computed tomography (CT) scans. Seven years later, she complained of a prominence and dull pain in her right thoraco-abdominal region. CT revealed an enlargement of the cystic lesion and infiltration into the intercostal subcutaneous tissue. We suspected the development of a malignancy inside the liver cyst such as cystadenocarcinoma, and she therefore underwent surgery. A tumor extirpation was performed, including the chest wall, from the 7th to the 10th rib, as well as a right hepatic lobectomy. Pathologically, the lesion consisted of severe inflammatory change with epithelioid cell granuloma and bone destruction without any malignant neoplasm. No specific pathogens were evident based on further histological and molecular examinations. Therefore the lesion was diagnosed to be a destructive granuloma associated with a long-standing hepatic cyst. Since undergoing surgery, the patient has been doing well without any signs of recurrence. PMID:16586558

  9. Multifunctional imaging signature for V-KI-RAS2 Kirsten rat sarcoma viral oncogene homolog (KRAS) mutations in colorectal cancer.

    PubMed

    Miles, Kenneth A; Ganeshan, Balaji; Rodriguez-Justo, Manuel; Goh, Vicky J; Ziauddin, Zia; Engledow, Alec; Meagher, Marie; Endozo, Raymondo; Taylor, Stuart A; Halligan, Stephen; Ell, Peter J; Groves, Ashley M

    2014-03-01

    This study explores the potential for multifunctional imaging to provide a signature for V-KI-RAS2 Kirsten rat sarcoma viral oncogene homolog (KRAS) gene mutations in colorectal cancer. This prospective study approved by the institutional review board comprised 33 patients undergoing PET/CT before surgery for proven primary colorectal cancer. Tumor tissue was examined histologically for presence of the KRAS mutations and for expression of hypoxia-inducible factor-1 (HIF-1) and minichromosome maintenance protein 2 (mcm2). The following imaging parameters were derived for each tumor: (18)F-FDG uptake ((18)F-FDG maximum standardized uptake value [SUVmax]), CT texture (expressed as mean of positive pixels [MPP]), and blood flow measured by dynamic contrast-enhanced CT. A recursive decision tree was developed in which the imaging investigations were applied sequentially to identify tumors with KRAS mutations. Monte Carlo analysis provided mean values and 95% confidence intervals for sensitivity, specificity, and accuracy. The final decision tree comprised 4 decision nodes and 5 terminal nodes, 2 of which identified KRAS mutants. The true-positive rate, false-positive rate, and accuracy (95% confidence intervals) of the decision tree were 82.4% (63.9%-93.9%), 0% (0%-10.4%), and 90.1% (79.2%-96.0%), respectively. KRAS mutants with high (18)F-FDG SUVmax and low MPP showed greater frequency of HIF-1 expression (P = 0.032). KRAS mutants with low (18)F-FDG SUV(max), high MPP, and high blood flow expressed mcm2 (P = 0.036). Multifunctional imaging with PET/CT and recursive decision-tree analysis to combine measurements of tumor (18)F-FDG uptake, CT texture, and perfusion has the potential to identify imaging signatures for colorectal cancers with KRAS mutations exhibiting hypoxic or proliferative phenotypes.

  10. Improvement of ablative margins by the intraoperative use of CEUS-CT/MR image fusion in hepatocellular carcinoma.

    PubMed

    Li, Kai; Su, Zhong-Zhen; Xu, Er-Jiao; Ju, Jin-Xiu; Meng, Xiao-Chun; Zheng, Rong-Qin

    2016-04-18

    To assess whether intraoperative use of contrast-enhanced ultrasound (CEUS)-CT/MR image fusion can accurately evaluate ablative margin (AM) and guide supplementary ablation to improve AM after hepatocellular carcinoma (HCC) ablation. Ninety-eight patients with 126 HCCs designated to undergo thermal ablation treatment were enrolled in this prospective study. CEUS-CT/MR image fusion was performed intraoperatively to evaluate whether 5-mm AM was covered by the ablative area. If possible, supplementary ablation was applied at the site of inadequate AM. The CEUS image quality, the time used for CEUS-CT/MR image fusion and the success rate of image fusion were recorded. Local tumor progression (LTP) was observed during follow-up. Clinical factors including AM were examined to identify risk factors for LTP. The success rate of image fusion was 96.2% (126/131), and the duration required for image fusion was 4.9 ± 2.0 (3-13) min. The CEUS image quality was good in 36.1% (53/147) and medium in 63.9% (94/147) of the cases. By supplementary ablation, 21.8% (12/55) of lesions with inadequate AMs became adequate AMs. During follow-up, there were 5 LTPs in lesions with inadequate AMs and 1 LTP in lesions with adequate AMs. Multivariate analysis showed that AM was the only independent risk factor for LTP (hazard ratio, 9.167; 95% confidence interval, 1.070-78.571; p = 0.043). CEUS-CT/MR image fusion is feasible for intraoperative use and can serve as an accurate method to evaluate AMs and guide supplementary ablation to lower inadequate AMs.

  11. Adherence to Radiology Recommendations in a Clinical CT Lung Screening Program.

    PubMed

    Alshora, Sama; McKee, Brady J; Regis, Shawn M; Borondy Kitts, Andrea K; Bolus, Christopher C; McKee, Andrea B; French, Robert J; Flacke, Sebastian; Wald, Christoph

    2018-02-01

    Assess patient adherence to radiologist recommendations in a clinical CT lung cancer screening program. Patients undergoing CT lung cancer screening between January 12, 2012, and June 12, 2013, were included in this institutional review board-approved retrospective review. Patients referred from outside our institution were excluded. All patients met National Comprehensive Cancer Network Guidelines Lung Cancer Screening high-risk criteria. Full-time program navigators used a CT lung screening program management system to schedule patient appointments, generate patient result notification letters detailing the radiologist follow-up recommendation, and track patient and referring physician notification of missed appointments at 30, 60, and 90 days. To be considered adherent, patients could be no more than 90 days past due for their next recommended examination as of September 12, 2014. Patients who died, were diagnosed with cancer, or otherwise became ineligible for screening were considered adherent. Adherence rates were assessed across multiple variables. During the study interval, 1,162 high-risk patients were screened, and 261 of 1,162 (22.5%) outside referrals were excluded. Of the remaining 901 patients, 503 (55.8%) were male, 414 (45.9%) were active smokers, 377 (41.8%) were aged 65 to 73, and >95% were white. Of the 901 patients, 772 (85.7%) were adherent. Most common reasons for nonadherence were patient refusal of follow-up exam (66.7%), inability to successfully contact the patient (20.9%), and inability to obtain the follow-up order from the referring provider (7.8%); 23 of 901 (2.6%) were discharged for other reasons. High rates of adherence to radiologist recommendations are achievable for in-network patients enrolled in a clinical CT lung screening program. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  12. Changes in entrance surface dose in relation to the location of shielding material in chest computed tomography

    NASA Astrophysics Data System (ADS)

    Kang, Y. M.; Cho, J. H.; Kim, S. C.

    2015-07-01

    This study examined the effects of entrance surface dose (ESD) on the abdomen and pelvis of the patient when undergoing chest computed tomography (CT) procedure, and evaluated the effects of ESD reduction depending on the location of radiation shield. For CT scanner, the 64-slice multi-detector computed tomography was used. The alderson radiation therapy phantom and optically stimulated luminescence dosimeter (OSLD), which enabled measurement from low to high dose, were also used. For measurement of radiation dose, the slice number from 9 to 21 of the phantom was set as the test range, which included apex up to both costophrenic angles. A total of 10 OSLD nanoDots were attached for measurement of the front and rear ESD. Cyclic tests were performed using the low-dose chest CT and high-resolution CT (HRCT) protocol on the following set-ups: without shielding; shielding only on the front side; shielding only on the rear side; and shielding for both front and rear sides. According to the test results, ESD for both front and rear sides was higher in HRCT than low-dose CT when radiation shielding was not used. It was also determined that, compared to the set-up that did not use the radiation shield, locating the radiation shield on the front side was effective in reducing front ESD, while locating the radiation shield on the rear side reduced rear ESD level. Shielding both the front and rear sides resulted in ESD reduction. In conclusion, it was confirmed that shielding the front and rear sides was the most effective method to reduce the ESD effect caused by scatter ray during radiography.

  13. Fifth-year surveillance computed tomography scanning after potentially curative resections for colorectal cancer.

    PubMed

    Walter, Catherine J; Al-Allak, Asmaa; Borley, Neil; Goodman, Anthony; Wheeler, James M D

    2013-02-01

    Optimal follow-up after colorectal resection for adenocarcinoma is yet to be determined. The aim of this study was to examine the role of a fifth-year surveillance Computed Tomography (CT) scan in detecting recurrence in our population. A retrospective analysis of all patients who had undergone potentially curative resections of colorectal adenocarcinomas between 2003 and 2004 was performed using electronic and casenote records. Data analysis was performed using Microsoft Office Excel 2007 and GnuPSPP statistical software. Two hundred and seven patients (111 male and 96 female) with a median age of 74 years (IQR 66-80) undergoing colorectal resections were studied. One hundred and twenty-one patients (58%) were alive and disease free at 5 years of whom 81 (67%) had received a fifth-year surveillance CT scan. Fifth-year scanning did not demonstrate any new colorectal metastases. However 6 (7%) scans revealed new, undiagnosed, non-colorectal malignancies. Thirty-four patients developed metastatic disease. All metastasis were diagnosed by 3½ years of follow-up. Eleven of these 34 cases presented after their second-year surveillance CT scan. Those patients with asymptomatic metastasis at the time of their discovery demonstrated improved likelihood of five year survival. This study showed no role for a fifth-year surveillance CT scan in the detection of resectable metastases, however there was a 7% pick up rate for detecting new malignancies. CT scanning beyond 2 years was needed to identify about one-third of the recurrences reported in this study. Copyright © 2012 Royal College of Surgeons of Edinburgh (Scottish charity number SC005317) and Royal College of Surgeons in Ireland. Published by Elsevier Ltd. All rights reserved.

  14. VirtualDose: a software for reporting organ doses from CT for adult and pediatric patients

    NASA Astrophysics Data System (ADS)

    Ding, Aiping; Gao, Yiming; Liu, Haikuan; Caracappa, Peter F.; Long, Daniel J.; Bolch, Wesley E.; Liu, Bob; Xu, X. George

    2015-07-01

    This paper describes the development and testing of VirtualDose—a software for reporting organ doses for adult and pediatric patients who undergo x-ray computed tomography (CT) examinations. The software is based on a comprehensive database of organ doses derived from Monte Carlo (MC) simulations involving a library of 25 anatomically realistic phantoms that represent patients of different ages, body sizes, body masses, and pregnant stages. Models of GE Lightspeed Pro 16 and Siemens SOMATOM Sensation 16 scanners were carefully validated for use in MC dose calculations. The software framework is designed with the ‘software as a service (SaaS)’ delivery concept under which multiple clients can access the web-based interface simultaneously from any computer without having to install software locally. The RESTful web service API also allows a third-party picture archiving and communication system software package to seamlessly integrate with VirtualDose’s functions. Software testing showed that VirtualDose was compatible with numerous operating systems including Windows, Linux, Apple OS X, and mobile and portable devices. The organ doses from VirtualDose were compared against those reported by CT-Expo and ImPACT—two dosimetry tools that were based on the stylized pediatric and adult patient models that were known to be anatomically simple. The organ doses reported by VirtualDose differed from those reported by CT-Expo and ImPACT by as much as 300% in some of the patient models. These results confirm the conclusion from past studies that differences in anatomical realism offered by stylized and voxel phantoms have caused significant discrepancies in CT dose estimations.

  15. Comprehensive CT Evaluation in Acute Ischemic Stroke: Impact on Diagnosis and Treatment Decisions

    PubMed Central

    Löve, Askell; Siemund, Roger; Andsberg, Gunnar; Cronqvist, Mats; Holtås, Stig; Björkman-Burtscher, Isabella

    2011-01-01

    Background. With modern CT imaging a comprehensive overview of cerebral macro- and microcirculation can be obtained within minutes in acute ischemic stroke. This opens for patient stratification and individualized treatment. Methods. Four patients with acute ischemic stroke of different aetiologies and/or treatments were chosen for illustration of the comprehensive CT protocol and its value in subsequent treatment decisions. The patients were clinically evaluated according to the NIHSS-scale, examined with the comprehensive CT protocol including both CT angiography and CT perfusion, and followed up by MRI. Results. The comprehensive CT examination protocol increased the examination time but did not delay treatment initiation. In some cases CT angiography revealed the cause of stroke while CT perfusion located and graded the perfusion defect with reasonable accuracy, confirmed by follow-up MR-diffusion. In the presented cases findings of the comprehensive CT examination influenced the treatment strategy. Conclusions. The comprehensive CT examination is a fast and safe method allowing accurate diagnosis and making way for individualized treatment in acute ischemic stroke. PMID:21603175

  16. Neurocognitive assessment in patients with a minor traumatic brain injury and an abnormal initial CT scan: Can cognitive evaluation assist in identifying patients who require surveillance CT brain imaging?

    PubMed

    Clements, Thomas W; Dunham, Michael; Kirkpatrick, Andrew; Rajakumar, Ruphus; Gratton, Carolyn; Lall, Rohan; McBeth, Paul; Ball, Chad G

    2018-05-01

    Evidence for repeat computed tomography (CT) in minor traumatic brain injury (mTBI) patients with intracranial pathology is scarce. The aim of this study was to investigate the utility of clinical cognitive assessment (COG) in defining the need for repeat imaging. COG performance was compared with findings on subsequent CT, and need for neurosurgery in mTBI patients (GCS 13-15 and positive CT findings). Of 152 patients, 65.8% received a COG (53.0% passed). Patients with passed COG underwent fewer repeat CT (43.4% vs. 78.7%; p = .001) and had shorter LOS (8.7 vs. 19.5; p < .05). Only 1 patient required neurosurgery after a passed COG. The negative predictive value of a normal COG was 90.6% (95%CI = 81.8%-95.4%). mTBI patients with an abnormal index CT who pass COG are less likely to undergo repeat CT head, and rarely require neurosurgery. The COG warrants further investigation to determine its role in omitting repeat head CT. Copyright © 2018 Elsevier Inc. All rights reserved.

  17. [Testicular cancer: a model to optimize the radiological follow-up].

    PubMed

    Stebler, V; Pauchard, B; Schmidt, S; Valerio, M; De Bari, B; Berthold, D

    2015-05-20

    Despite being rare cancers, testicular seminoma and non-seminoma play an important role in oncology: they represent a model on how to optimize radiological follow-up, aiming at a lowest possible radiation exposure and secondary cancer risk. Males diagnosed with testicular cancer undergo frequently prolonged follow-up with CT-scans with potential toxic side effects, in particular secondary cancers. To reduce the risks linked to ionizing radiation, precise follow-up protocols have been developed. The number of recommended CT-scanners has been significantly reduced over the last 10 years. The CT scanners have evolved technically and new acquisition protocols have the potential to reduce the radiation exposure further.

  18. Tracking the Remodeling of SNOMED CT's Bacterial Infectious Diseases.

    PubMed

    Ochs, Christopher; Case, James T; Perl, Yehoshua

    2016-01-01

    SNOMED CT's content undergoes many changes from one release to the next. Over the last year SNOMED CT's Bacterial infectious disease subhierarchy has undergone significant editing to bring consistent modeling to its concepts. In this paper we analyze the stated and inferred structural modifications that affected the Bacterial infectious disease subhierarchy between the Jan 2015 and Jan 2016 SNOMED CT releases using a two-phased approach. First, we introduce a methodology for creating a human readable list of changes. Next, we utilize partial-area taxonomies, which are compact summaries of SNOMED CT's content and structure, to identify the "big picture" changes that occurred in the subhierarchy. We illustrate how partial-area taxonomies can be used to help identify groups of concepts that were affected by these editing operations and the nature of these changes. Modeling issues identified using our two-phase methodology are discussed.

  19. Results of initial low-dose computed tomographic screening for lung cancer.

    PubMed

    Church, Timothy R; Black, William C; Aberle, Denise R; Berg, Christine D; Clingan, Kathy L; Duan, Fenghai; Fagerstrom, Richard M; Gareen, Ilana F; Gierada, David S; Jones, Gordon C; Mahon, Irene; Marcus, Pamela M; Sicks, JoRean D; Jain, Amanda; Baum, Sarah

    2013-05-23

    Lung cancer is the largest contributor to mortality from cancer. The National Lung Screening Trial (NLST) showed that screening with low-dose helical computed tomography (CT) rather than with chest radiography reduced mortality from lung cancer. We describe the screening, diagnosis, and limited treatment results from the initial round of screening in the NLST to inform and improve lung-cancer-screening programs. At 33 U.S. centers, from August 2002 through April 2004, we enrolled asymptomatic participants, 55 to 74 years of age, with a history of at least 30 pack-years of smoking. The participants were randomly assigned to undergo annual screening, with the use of either low-dose CT or chest radiography, for 3 years. Nodules or other suspicious findings were classified as positive results. This article reports findings from the initial screening examination. A total of 53,439 eligible participants were randomly assigned to a study group (26,715 to low-dose CT and 26,724 to chest radiography); 26,309 participants (98.5%) and 26,035 (97.4%), respectively, underwent screening. A total of 7191 participants (27.3%) in the low-dose CT group and 2387 (9.2%) in the radiography group had a positive screening result; in the respective groups, 6369 participants (90.4%) and 2176 (92.7%) had at least one follow-up diagnostic procedure, including imaging in 5717 (81.1%) and 2010 (85.6%) and surgery in 297 (4.2%) and 121 (5.2%). Lung cancer was diagnosed in 292 participants (1.1%) in the low-dose CT group versus 190 (0.7%) in the radiography group (stage 1 in 158 vs. 70 participants and stage IIB to IV in 120 vs. 112). Sensitivity and specificity were 93.8% and 73.4% for low-dose CT and 73.5% and 91.3% for chest radiography, respectively. The NLST initial screening results are consistent with the existing literature on screening by means of low-dose CT and chest radiography, suggesting that a reduction in mortality from lung cancer is achievable at U.S. screening centers that have staff experienced in chest CT. (Funded by the National Cancer Institute; NLST ClinicalTrials.gov number, NCT00047385.).

  20. Assessing the Content of YouTube Videos in Educating Patients Regarding Common Imaging Examinations.

    PubMed

    Rosenkrantz, Andrew B; Won, Eugene; Doshi, Ankur M

    2016-12-01

    To assess the content of currently available YouTube videos seeking to educate patients regarding commonly performed imaging examinations. After initial testing of possible search terms, the first two pages of YouTube search results for "CT scan," "MRI," "ultrasound patient," "PET scan," and "mammogram" were reviewed to identify educational patient videos created by health organizations. Sixty-three included videos were viewed and assessed for a range of features. Average views per video were highest for MRI (293,362) and mammography (151,664). Twenty-seven percent of videos used a nontraditional format (eg, animation, song, humor). All videos (100.0%) depicted a patient undergoing the examination, 84.1% a technologist, and 20.6% a radiologist; 69.8% mentioned examination lengths, 65.1% potential pain/discomfort, 41.3% potential radiation, 36.5% a radiology report/results, 27.0% the radiologist's role in interpretation, and 13.3% laboratory work. For CT, 68.8% mentioned intravenous contrast and 37.5% mentioned contrast safety. For MRI, 93.8% mentioned claustrophobia, 87.5% noise, 75.0% need to sit still, 68.8% metal safety, 50.0% intravenous contrast, and 0.0% contrast safety. For ultrasound, 85.7% mentioned use of gel. For PET, 92.3% mentioned radiotracer injection, 61.5% fasting, and 46.2% diabetic precautions. For mammography, unrobing, avoiding deodorant, and possible additional images were all mentioned by 63.6%; dense breasts were mentioned by 0.0%. Educational patient videos on YouTube regarding common imaging examinations received high public interest and may provide a valuable patient resource. Videos most consistently provided information detailing the examination experience and less consistently provided safety information or described the presence and role of the radiologist. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  1. Can handheld micropower impulse radar technology be used to detect pneumothorax? Initial experience in a European trauma centre.

    PubMed

    Albers, C E; Haefeli, P C; Zimmermann, H; de Moya, M; Exadaktylos, A K

    2013-05-01

    Pneumothoraces are a common injury pattern in emergency medicine. Rapid and safe identification can reduce morbidity and mortality. A new handheld, battery powered device, the Pneumoscan (CE 561036, PneumoSonics Inc., Cleveland, OH, USA), using micropower impulse radar (MIR) technology, has recently been introduced in Europe for the rapid and reliable detection of PTX. However, this technology has not yet been tested in trauma patients. This is the first quality control evaluation to report on emergency room performance of a new device used in the trauma setting. This study was performed at a Level I trauma centre in Switzerland. All patients with thoracic trauma and undergoing chest X-ray and CT-scan were eligible for the study. Readings were performed before the chest X-ray and CT scan. The patients had eight lung fields tested (four on each side). All readings with the Pneumoscan were performed by two junior residents in our department who had previously received an instructional tutorial of 15min. The qualitative MIR results were blinded, and stored on the device. We then compared the results of the MIR to those of the clinical examination, chest X-ray and CT-scan. 50 patients were included, with a mean age of 46 (SD 17) years. Seven patients presented with PTX diagnosed by CT; six of these were detected by Pneumoscan, leading to an overall sensitivity of 85.7 (95% confidence interval 42.1-99.6)%. Only two of seven PTX were found during clinical examination and on chest X-ray (sensitivity 28.6 (95% CI 3.7-71.0)%). Of the remaining 43 of 50 patients without PTX, one false-positive PTX was found by the Pneumoscan, resulting in a specificity of 97.7 (95% CI 87.7-99.9)%. The Pneumoscan is an easy to use handheld technology with reliable results. In this series, the sensitivity to detect a PTX by the Pneumoscan was higher than by clinical examination and chest X-ray. Further studies with higher case numbers and a prospective study design are needed to confirm our findings. Copyright © 2012 Elsevier Ltd. All rights reserved.

  2. Evaluation of an imaging protocol using ultrasound as the primary diagnostic modality in pediatric patients with superficial soft tissue infections of the face and neck.

    PubMed

    Sethia, Rishabh; Mahida, Justin B; Subbarayan, Rahul A; Deans, Katherine J; Minneci, Peter C; Elmaraghy, Charles A; Essig, Garth F

    2017-05-01

    To determine the clinical impact of an initiative to use ultrasound (US) as the primary diagnostic modality for children with superficial face and neck infections versus use of computed tomography (CT). Children with a diagnosis of lymphadenitis, face or neck abscess, or face and neck cellulitis were retrospectively evaluated by the otolaryngology service. Patients were separated into two groups based on implementation of a departmental initiative to use US as the primary diagnostic modality. The pre-implementation cohort consisted of patients treated prior to the initiative (2006-2009) and the current protocol cohort consisted of patients treated after the initiative was started (2010-2013). Demographics, use of US or CT, necessity of surgical intervention, and failure of medical management were compared. Three hundred seventy three children were evaluated; 114 patients were included in the pre-implementation cohort and 259 patients were included in the current protocol cohort for comparison. Patients presenting during the current protocol period were more likely to undergo US (pre-implementation vs. current protocol, p-value) (12% vs. 49%, p < 0.0001) and less likely to undergo CT (66% vs. 41%, p < 0.0001) for their initial evaluation. There were no differences in the percentage of children who underwent prompt surgical drainage, prompt discharge without surgery, or trial inpatient observation. There were also no differences in the rate of treatment failure for patients undergoing prompt surgery or prompt discharge on antibiotics. For those patients who underwent repeat evaluation following trial medical management, US was used more frequently in the current protocol period (4% vs. 20%, p = 0.002) with no difference in CT use, selected treatment strategy, or treatment failure rates. Increased use of US on initial evaluation of children with superficial face and neck infections resulted in decreased CT utilization, without negatively impacting outcome. Decreasing pediatric radiation exposure and potential long-term effects is of primary importance. Copyright © 2017. Published by Elsevier B.V.

  3. Splenic trauma during abdominal wall liposuction: a case report

    PubMed Central

    Harnett, Paul; Koak, Yashwant; Baker, Daryl

    2008-01-01

    Summary A 35-year-old woman collapsed 18 hours after undergoing abdominal wall liposuction. Abdominal CT scan revealed a punctured spleen. She underwent an emergency splenectomy and made an uneventful recovery. PMID:18387911

  4. Efficacy of Lens Protection Systems: Dependency on Different Cranial CT Scans in The Acute Stroke Setting.

    PubMed

    Guberina, Nika; Forsting, Michael; Ringelstein, Adrian

    2017-06-15

    To evaluate the dose-reduction potential with different lens protectors for patients undergoing cranial computed tomography (CT) scans. Eye lens dose was assessed in vitro (α-Al2O3:C thermoluminescence dosemeters) using an Alderson-Rando phantom® in cranial CT protocols at different CT scanners (SOMATOM-Definition-AS+®(CT1) and SOMATOM-Definition-Flash® (CT2)) using two different lens-protection systems (Somatex® (SOM) and Medical Imaging Systems® (MIS)). Summarised percentage of the transmitted photons: (1) CT1 (a) unenhanced CT (nCT) with gantry angulation: SOM = 103%, MIS = 111%; (2) CT2 (a) nCT without gantry angulation: SOM = 81%, MIS = 91%; (b) CT angiography (CTA) with automatic dose-modulation technique: SOM = 39%, MIS = 74%; (c) CTA without dose-modulation technique: SOM = 22%, MIS = 48%; (d) CT perfusion: SOM = 44%, MIS = 69%. SOM showed a higher dose-reduction potential than MIS maintaining equal image quality. Lens-protection systems are most effective in CTA protocols without dose-reduction techniques. Lens-protection systems lower the average eye lens dose during CT scans up to 1/3 (MIS) and 2/3 (SOM), respectively, if the eye lens is exposed to the direct beam of radiation. Considering both the CT protocol and the material of lens protectors, they seem to be mandatory for reducing the radiation exposure of the eye lens. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  5. Adult advanced chronic lymphocytic leukemia: computational analysis of whole-body CT documents a bone structure alteration.

    PubMed

    Fiz, Francesco; Marini, Cecilia; Piva, Roberta; Miglino, Maurizio; Massollo, Michela; Bongioanni, Francesca; Morbelli, Silvia; Bottoni, Gianluca; Campi, Cristina; Bacigalupo, Andrea; Bruzzi, Paolo; Frassoni, Francesco; Piana, Michele; Sambuceti, Gianmario

    2014-06-01

    To assess the presence of alteration of bone structure and bone marrow metabolism in adult patients who were suspected of having advanced chronic lymphocytic leukemia (ACLL) by using a computational prognostic model that was based on computational analysis of positron emission tomography (PET)/computed tomography (CT) images. In this retrospective study, all patients signed written informed consent as a requisite to undergo PET/CT examination. However, due to its observational nature, approval from the ethical committee was not deemed necessary. Twenty-two previously untreated chronic lymphocytic leukemia patients underwent PET/CT for disease progression. PET/CT images were analyzed by using dedicated software, capable of recognizing an external 2-pixel bone ring whose Hounsfield coefficient served as cutoff to recognize trabecular and compact bone. PET/CT data from 22 age- and sex-matched control subjects were used as comparison. All data are reported as means ± standard deviations. The Student t test, log-rank, or Cox proportional hazards model were used as appropriate, considering a difference with a P value of less than .05 as significant. Trabecular bone was expanded in ACLL patients and occupied a larger fraction of the skeleton with respect to control subjects (mean, 39% ± 5 [standard deviation] vs 31% ± 7; ie, 32 of 81 mL/kg of ideal body weight vs 27 of 86 mL/kg of ideal body weight, respectively; P < .001). After stratification according to median value, patients with a ratio of trabecular to skeletal bone volume of more than 37.3% showed an actuarial 2-year survival of 18%, compared with 82% for those with a ratio of less than 37.3% (P < .001), independent from age, sex, biological markers, and disease duration. These data suggest that computational assessment of skeletal alterations might represent a new window for prediction of the clinical course of the disease.

  6. Physiological and computed tomographic predictors of outcome from lung volume reduction surgery.

    PubMed

    Washko, George R; Martinez, Fernando J; Hoffman, Eric A; Loring, Stephen H; Estépar, Raúl San José; Diaz, Alejandro A; Sciurba, Frank C; Silverman, Edwin K; Han, MeiLan K; Decamp, Malcolm; Reilly, John J

    2010-03-01

    Previous investigations have identified several potential predictors of outcomes from lung volume reduction surgery (LVRS). A concern regarding these studies has been their small sample size, which may limit generalizability. We therefore sought to examine radiographic and physiologic predictors of surgical outcomes in a large, multicenter clinical investigation, the National Emphysema Treatment Trial. To identify objective radiographic and physiological indices of lung disease that have prognostic value in subjects with chronic obstructive pulmonary disease being evaluated for LVRS. A subset of the subjects undergoing LVRS in the National Emphysema Treatment Trial underwent preoperative high-resolution computed tomographic (CT) scanning of the chest and measures of static lung recoil at total lung capacity (SRtlc) and inspiratory resistance (Ri). The relationship between CT measures of emphysema, the ratio of upper to lower zone emphysema, CT measures of airway disease, SRtlc, Ri, the ratio of residual volume to total lung capacity (RV/TLC), and both 6-month postoperative changes in FEV(1) and maximal exercise capacity were assessed. Physiological measures of lung elastic recoil and inspiratory resistance were not correlated with improvement in either the FEV(1) (R = -0.03, P = 0.78 and R = -0.17, P = 0.16, respectively) or maximal exercise capacity (R = -0.02, P = 0.83 and R = 0.08, P = 0.53, respectively). The RV/TLC ratio and CT measures of emphysema and its upper to lower zone ratio were only weakly predictive of postoperative changes in both the FEV(1) (R = 0.11, P = 0.01; R = 0.2, P < 0.0001; and R = 0.23, P < 0.0001, respectively) and maximal exercise capacity (R = 0.17, P = 0.0001; R = 0.15, P = 0.002; and R = 0.15, P = 0.002, respectively). CT assessments of airway disease were not predictive of change in FEV(1) or exercise capacity in this cohort. The RV/TLC ratio and CT measures of emphysema and its distribution are weak but statistically significant predictors of outcome after LVRS.

  7. Radiological features for the approach in trans-sphenoidal pituitary surgery.

    PubMed

    Twigg, Victoria; Carr, Simon D; Balakumar, Ramkishan; Sinha, Saurabh; Mirza, Showkat

    2017-08-01

    In order to perform trans-sphenoidal endoscopic pituitary surgery safely and efficiently it is important to identify anatomical and pituitary disease features on the pre-operative CT and MRI scans; thereby minimising the risk to surrounding structures and optimising outcomes. We aim to create a checklist to streamline pre-operative planning. We retrospectively reviewed pre-operative CT and MRI scans of 100 adults undergoing trans-sphenoidal endoscopic pituitary surgery. Radiological findings and their incidence included deviated nasal septum (62%), concha bullosa (32%), bony dehiscence of the carotid arteries (18%), sphenoid septation overlying the internal carotid artery (24% at the sella) and low lying CSF (32%). The mean distance of the sphenoid ostium to the skull base was 10 mm (range 2.7-17.6 mm). We also describe the 'teddy bear' sign which when present on an axial CT indicates the carotid arteries will be identifiable intra-operatively. There are significant variations in the anatomical and pituitary disease features between patients. We describe a number of features on pre-operative scans and have devised a checklist including a new 'teddy bear' sign to aid the surgeon in the anatomical assessment of patients undergoing trans-sphenoidal pituitary surgery.

  8. FDG-PET/CT in the evaluation of anal carcinoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cotter, Shane E.; Medical Scientist Training Program, Washington University School of Medicine, St. Louis, MO; Grigsby, Perry W.

    2006-07-01

    Purpose: Surgical staging and treatment of anal carcinoma has been replaced by noninvasive staging studies and combined modality therapy. In this study, we compare computed tomography (CT) and physical examination to [{sup 18}F]-fluoro-2-deoxy-D-glucose-positron emission tomography/computed tomography (FDG-PET/CT) in the staging of carcinoma of the anal canal, with special emphasis on determination of spread to inguinal lymph nodes. Methods and Materials: Between July 2003 and July 2005, 41 consecutive patients with biopsy-proved anal carcinoma underwent a complete staging evaluation including physical examination, CT, and 2-FDG-PET/CT. Patients ranged in age from 30 to 89 years. Nine men were HIV-positive. Treatment was withmore » standard Nigro regimen. Results: [{sup 18}F]-fluoro-2-deoxy-D-glucose-positron emission tomography/computed tomography (FDG-PET/CT) detected 91% of nonexcised primary tumors, whereas CT visualized 59%. FDG-PET/CT detected abnormal uptake in pelvic nodes of 5 patients with normal pelvic CT scans. FDG-PET/CT detected abnormal nodes in 20% of groins that were normal by CT, and in 23% without abnormality on physical examination. Furthermore, 17% of groins negative by both CT and physical examination showed abnormal uptake on FDG-PET/CT. HIV-positive patients had an increased frequency of PET-positive lymph nodes. Conclusion: [{sup 18}F]-fluoro-2-deoxy-D-glucose-positron emission tomography/computed tomography detects the primary tumor more often than CT. FDG-PET/CT detects substantially more abnormal inguinal lymph nodes than are identified by standard clinical staging with CT and physical examination.« less

  9. Shared decision-making: is it time to obtain informed consent before radiologic examinations utilizing ionizing radiation? Legal and ethical implications.

    PubMed

    Berlin, Leonard

    2014-03-01

    Concerns about the possibility of developing cancer due to diagnostic imaging examinations utilizing ionizing radiation exposure are increasing. Research studies of survivors of atomic bomb explosions, nuclear reactor accidents, and other unanticipated exposures to similar radiation have led to varying conclusions regarding the stochastic effects of radiation exposure. That high doses of ionizing radiation cause cancer in humans is generally accepted, but the question of whether diagnostic levels of radiation cause cancer continues to be hotly debated. It cannot be denied that overexposure to ionizing radiation beyond a certain threshold, which has not been exactly determined, does generate cancer. This causes a dilemma: what should patients be informed about the possibility that a CT or similar examination might cause cancer later in life? At present, there is no consensus in the radiology community as to whether informed consent must be obtained from a patient before the patient undergoes a CT or similar examination. The author analyzes whether there is a legal duty mandating radiologists to obtain such informed consent but also, irrespective of the law, whether there an ethical duty that compels radiologists to inform patients of potential adverse effects of ionizing radiation. Over the past decade, there has been a noticeable shift from a benevolent, paternalistic approach to medical care to an autonomy-based, shared-decision-making approach, whereby patient and physician work as partners in determining what is medically best for the patient. Radiologists should discuss the benefits and hazards of imaging with their patients. Copyright © 2014. Published by Elsevier Inc.

  10. TC99m MDP bone scan in evaluation of painful scoliosis

    PubMed Central

    Nilegaonkar, Sujit; Sonar, Sameer; Ranade, Ashish; Khadilkar, Madhav

    2010-01-01

    A 18-year-old male presented with low back ache. The patient was investigated and was diagnosed to have painful scoliosis. X-ray and other examinations could not reveal any diagnosis. The patient was referred to undergo bone scan on clinical suspicion of osteoid osteoma and to rule out stress fracture if any. Planar bone scan was performed, which showed a lesion in L3 vertebra and was further evaluated with SPECT (Single photon emission computed tomography) study to characterize the lesion. On SPECT examination, the classical features of osteoid osteoma, the double density sign (11), was noted in the pars interarticularis region. These findings were confirmed by a CT scan, which showed a sclerotic lesion in pars interarticularis of L3 vertebra. The patient was posted for operation and was relieved of symptoms in the postoperative follow-up. PMID:21188068

  11. Postoperative PET/CT and target delineation before adjuvant radiotherapy in patients with oral cavity squamous cell carcinoma.

    PubMed

    Dutta, Pinaki R; Riaz, Nadeem; McBride, Sean; Morris, Luc G; Patel, Snehal; Ganly, Ian; Wong, Richard J; Palmer, Frank; Schöder, Heiko; Lee, Nancy

    2016-04-01

    The purpose of this study was for us to present our evaluation of the effectiveness of positron emission tomography (PET)/CT imaging in postoperative patients with oral cavity squamous cell carcinoma (SCC) before initiating adjuvant radiation therapy. Treatment planning PET/CT scans were obtained in 44 patients with oral cavity SCC receiving adjuvant radiation. We identified target areas harboring macroscopic disease requiring higher radiation doses or additional surgery. Fourteen PET/CT scans were abnormal. Thirteen patients underwent surgery and/or biopsy, increased radiation dose, and/or addition of chemotherapy. Eleven patients received higher radiation doses. Patients undergoing imaging >8 weeks were more likely to have abnormal results (p = .01). One-year distant metastases-free survival was significantly worse in patients with positive PET/CT scans (61.5% vs 92.7%; p = .01). The estimated positive predictive value (PPV) was 38% for postoperative PET/CT scanning. We demonstrated that 32% of patients have abnormal PET/CT scans resulting in management changes. Patients may benefit from postoperative PET/CT imaging to optimize adjuvant radiation treatment planning. © 2015 Wiley Periodicals, Inc. Head Neck 38: E1285-E1293, 2016. © 2015 Wiley Periodicals, Inc.

  12. Likelihood of aneurysmal subarachnoid haemorrhage in patients with normal unenhanced CT, CSF xanthochromia on spectrophotometry and negative CT angiography.

    PubMed

    Rana, A K; Turner, H E; Deans, K A

    2013-01-01

    Patients with suspected subarachnoid haemorrhage, a normal noncontrast computed tomography (CT) and cerebrospinal fluid (CSF) evidence of haemoglobin breakdown products often undergo CT angiography (CTA). If this is normal, then invasive catheter angiography may be offered. In current clinical practice, haemoglobin breakdown products are detected by spectrophotometry rather than visible xanthochromia, and CTA is performed on multidetector scanners. The aim of this study was to determine if such patients should still have a catheter angiography, given the associated risks. Patients positive for CSF spectrophotometry (n=26) were retrospectively identified from the clinical biochemistry information system and imaging data from the electronic radiology records were reviewed. Discharge letters were consulted to relate the biochemistry and radiology results to the final diagnosis. 15 patients with CT angiography were found. Nine patients had normal CT angiography. No causative aneurysms had been missed. One patient had small, coincidental aneurysms missed on initial reading of the CTA. The likelihood of a clinically significant aneurysm in a patient who is CT negative, lumbar puncture positive and CTA negative is low. Double reporting of negative CT angiograms may be advisable.

  13. Prevalence of Poor Bone Quality in Women Undergoing Spinal Fusion Using Biomechanical-CT Analysis.

    PubMed

    Burch, Shane; Feldstein, Michael; Hoffmann, Paul F; Keaveny, Tony M

    2016-02-01

    Retrospective, cross-sectional analysis of vertebral bone quality in spine-fusion patients at a single medical center. To characterize the prevalence of osteoporosis and fragile bone strength in a spine-fusion population of women with an age range of 50 years to 70 years. Fragile bone strength is defined as the level of vertebral strength below which a patient is at as high a risk of future vertebral fracture as a patient having bone density-defined osteoporosis. Poor bone quality--defined here as the presence of either osteoporosis or fragile bone strength--is a risk factor for spine-fusion patients that often goes undetected but can now be assessed preoperatively by additional postprocessing of computed tomography (CT) scans originally ordered for perioperative clinical assessment. Utilizing such perioperative CT scans for a cohort of 98 women (age range: 51-70 yr) about to undergo spine fusion, we retrospectively used a phantomless calibration technique and biomechanical-CT postprocessing analysis to measure vertebral trabecular bone mineral density (BMD) (in mg/cm³) and by nonlinear finite element analysis, vertebral compressive strength (in Newtons, N) in the L1 or L2 vertebra. Preestablished validated threshold values were used to define the presence of osteoporosis (trabecular BMD of 80 mg/cm³ or lower) and fragile bone strength (vertebral strength of 4500 N or lower). Fourteen percent of the women tested positive for osteoporosis, 27% tested positive for fragile bone strength, and 29% were classified as having poor bone quality (either osteoporosis or fragile bone strength). Over this narrow age range, neither BMD nor vertebral strength were significantly correlated with age, weight, height, or body mass index (P values 0.14-0.97 for BMD; 0.13-0.51 for strength). Poor bone quality appears to be common in women between ages 50 years and 70 years undergoing spinal fusion surgery. 3.

  14. Use of a frameless computed tomography-guided stereotactic biopsy system for nasal biopsy in five dogs.

    PubMed

    Kuhlman, Gregory M; Taylor, Amanda R; Thieman-Mankin, Kelley M; Griffin, Jay; Cook, Audrey K; Levine, Jonathan M

    2016-04-15

    5 dogs (median age, 9 years; median body weight, 31 kg [68.2 lb]) with undefined nasal masses were examined after undergoing CT of the head and nasal biopsy via a rostral rhinoscopic or unaided (blind) approach because histologic results for collected biopsy specimens (inflammatory, necrotic, or hemorrhagic disease) suggested the specimens were nonrepresentative of the underlying disease process identified via CT (aggressive or malignant disease). Clinical signs at the time dogs were evaluated included open-mouth breathing, sneezing, or unilateral epistaxis. Histologic findings pertaining to the original biopsy specimens were suggestive of benign processes such as inflammation. In an attempt to obtain better representative specimens, a frameless CT-guided stereotactic biopsy system (CTSBS) was used to collect additional biopsy specimens from masses within the nasal and sinus passages of the dogs. The second set of biopsy specimens was histologically evaluated. Histologic evaluation of biopsy specimens collected via the CTSBS revealed results suggestive of malignant neoplasia (specifically, chondrosarcoma, hemangiopericytoma, or undifferentiated sarcoma) for 3 dogs, mild mixed-cell inflammation for 1 dog, and hamartoma for 1 dog. No complications were reported. These findings resulted in a change in treatment recommendations for 3 dogs and confirmed that no additional treatment was required for 1 dog (with hamartoma). For the remaining dog, in which CT findings and clinical history were strongly suggestive of neoplasia, the final diagnosis was rhinitis. Biopsy specimens were safely collected from masses within the nasal and sinus passages of dogs by use of a frameless CTSBS, allowing a definitive diagnosis that was unachievable with other biopsy approaches.

  15. Is the Keros classification alone enough to identify patients with the 'dangerous ethmoid'? An anatomical study.

    PubMed

    Skorek, Andrzej; Tretiakow, Dmitry; Szmuda, Tomasz; Przewozny, Tomasz

    2017-02-01

    By means of three-dimensional display of the critical measurements, the authors suggest a novel definition of 'dangerous ethmoid'. Parallel to Keros type III, the proposed determining factors include: olfactory fossa width >6 mm, its distance to the medial nasal concha (turbinate) <20 mm and to the orbit interval of <10 mm. Clinical evaluation of these preliminary criteria based only on radiological data is required and underway. Detailed pre-operative assessment of sinus computer tomography (CT) scans reduces the frequency of severe complications in patients undergoing endoscopic sinus surgery (ESS). The authors aimed to identify a sub-set of anatomical features pre-disposing to major post-operative complications. Sinus computer tomography (CT) scans of patients of a single institution qualified for ESS were examined. Besides the Keros classification, authors focused on the anatomic measurements as follows: the olfactory fossa depth, width, and its distance from the medial nasal concha and the medial wall of the orbit (referred to as 'critical measurements'). The sample comprised 120 consecutive CT exams, without clinical validation. Keros type I, II, and III was noted in 9.2%, 75.8%, and 15.0% of cases, respectively. Despite some statistically significant correlations, it was not possible to identify the patient age, sex, and side of body clearly correlating with the critical measurements.

  16. Sexually Transmitted Infections: A Novel Screening Strategy for Improving Women's Health in Vulnerable Populations.

    PubMed

    Frati, Elena R; Fasoli, Ester; Martinelli, Marianna; Colzani, Daniela; Bianchi, Silvia; Carnelli, Luciana; Amendola, Antonella; Olivani, Pierfranco; Tanzi, Elisabetta

    2017-06-20

    Migrant women are one of the most vulnerable population to health problems and well-being. This study aimed at implementing a counseling and preventive strategy for sexually transmitted infections (STIs) in undocumented migrant women in Milan, Italy. Women (ages 18-65) were enrolled at the NAGA Centre (2012-2013) and asked for a urine sample in order to carry out molecular detection of Human papillomavirus (HPV), Chlamydia trachomatis ( Ct ), Trichomonas vaginalis ( Tv ), Neisseria gonorrhoeae ( Ng )-DNA. Socio-demographic and sexual behavior information were collected. All HPV/ Ct + women were offered Pap tests and/or were prescribed antibiotic treatment. 537/757 women participated in the study (acceptability rate: 70.9%). Most of the women were from Latin America (45.6%) and Eastern Europe (30.7%); >60% of them had stable partners, did not use contraception and had had at least one pregnancy. The prevalence rates of HPV, Ct , Tv and Ng infections were 24.2%, 7.8%, 4.8% and 0%, respectively. In all, 43.2% of the positive women agreed to undergo a gynecological examination and accepted suitable treatment. This study shows an overall high prevalence of STIs in undocumented migrant women in Milan. The screening strategy based on counseling and urine testing contributed to the successfully high acceptability rate. More appropriate health services that adequately address all aspects of women's health are required.

  17. Ectopic ACTH and CRH co-secreting tumor localized by 68Ga-DOTA-TATE PET/CT

    PubMed Central

    Papadakis, Georgios Z.; Bagci, Ulas; Sadowski, Samira M.; Patronas, Nicholas J.; Stratakis, Constantine A.

    2015-01-01

    Diagnosis of ectopic adrenocorticotropic hormone (ACTH) and corticotropin releasing hormone (CRH) co-secreting tumors causing Cushing syndrome (CS) is challenging, since these tumors are rare and their diagnosis is frequently confused with Cushing disease (CD), due to the effect of CRH on the pituitary. We report a case of a 21-year-old male who was referred to our institution with persistent hypercortisolemia and CS after undergoing unnecessary transsphenoidal surgery (TSS). 68Ga-DOTA-TATE PET/CT revealed increased tracer uptake in the thymus which was histologically proved to be neuroendocrine tumor (NET) staining positive for ACTH and CRH. Imaging with 18F-FDG PET/CT was not diagnostic. PMID:26018709

  18. FDG PET/CT Findings in Primary Diffuse Large B-cell Lymphoma, Leg Type.

    PubMed

    Ni, Chiayi; Lewis, Michael; Berenji, Gholam

    2016-01-01

    A 64-year-old man presented with complaints of worsening left foot pain and swelling. MRI showed a soft tissue mass overlying the dorsolateral aspect of the left foot. Following a 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT), the left foot mass was biopsied and pathology indicated a diagnosis of primary diffuse large B-cell lymphoma, leg type (PDLBCL, LT). Review of the PET/CT images demonstrated hypermetabolic activity associated with the left foot mass, multiple subcutaneous nodules/nodes, sclerotic osseous lesions in the lower extremities, and left external iliac/left inguinal lymphadenopathy. At the moment, the patient is undergoing chemotherapy.

  19. [The status of domestic PET/CT attendance in the light of the waiting list data].

    PubMed

    Galuska, László; Balkay, László

    2010-06-01

    The aim of the study is to demonstrate the diagnostic and geographical distribution of the domestic PET/CT examinations financed by the OEP based on the data from the waiting list of the past 4 years. The analysis of the demonstrated data can support the rational usage of PET/CT examination contingents in the domestic oncological attendance, which has growing importance. PET examinations with oncological aims have started in Debrecen more than 10 years ago. In 2005 already 1500 PET examinations have been carried out. According to the governmental regulation accepted in 2006, OEP ensures the financing of the three PET/CT centers until 2012, which means 12,000 examinations in 2012. However, the number of domestic oncological patients requiring PET/CT examinations can reach the number of 20,000-30,000 patients. The study summarizes the number of patients who applied for PET/CT examinations for the first time and later again between 2006 and 2010, based on the data of the waiting list, and the change of the patient assigning diagnosis and the number of examinations carried out with 18F-FDG and with 11C-methionine. The study demonstrates the number of examinations by counties which characterize the population's access to PET/CT. The assigning diagnosis in 2007 was already widespread and focused on problems. After the regulation came in to force in 2008 the possibilities significantly decreased. Clinical cases which were efficiently examined with PET/CT earlier were left out from the indication list. The distribution by county is uneven, although the number of examinations increases year by year. The number of repeated examinations increases as well. As a conclusion, the annual PET/CT examination contingents are constantly exploited. This might seem sufficient, because the method has not become a part of the oncological routine in all counties. Although the current indication list includes the most frequent oncological cases requiring PET/CT, the abandoning of the less frequent ones narrowed the professional latitude, which is disadvantageous for the patients suffering from such diseases. The radiopharmacon supply of PET/CT centers is inadequate thus they cannot provide modern oncological diagnostic attendance in case of frequent types of cancer (such as prostate). In the long run the growing number of repeated PET/CT examinations built in the oncological professional protocol has to be taken into account.

  20. Extravasation of contrast medium during CT examination: an observational case-control study

    PubMed Central

    Alami, Zayneb; Nasri, Siham; Ahid, Samir; Kacem, Hanane Hadj

    2015-01-01

    Introduction Extravasation is an adverse reaction to intravenous injection of contrast medium (CM) during CT examination. The objectives of this study are to determine the frequency, management and outcomes of extravasations and to assess risk factors for extravasation. Methods Every incident of extravasation which occurred between March 2012 and March 31, 2013 was recorded in an extravasation form. Ethics Committee approval was obtained and the patients gave their consent to participate in the study. Data collected in the form included patients’ age, sex, comorbidities, symptoms, CM used, injection mode, site and rate, extravasated volume, location of extravasation, severity of injury, treatment and patient outcome. Each case was matched with 4 controls of the same age ± 5 years and the same gender when possible. Results Extravasation occurred in 18 (7 women, 11 men) out of 2,000 injections of CM (0.9%) with a median age of 53 (10-78) years. Automated injection was performed in all cases with a mean rate of 1.7ml/s. Large extravasated volumes (≥ 50ml) were more observed in patients undergoing CT angiography (28.6% vs. 6.6%, although not significant P=0.112). Multivariate analysis revealed a significant association between patients with cardiac diseases and extravasation (OR: 7.3, 95% CI (1.09-49.05), P=0.04) whereas the injection rate is a protective factor from extravasation (P=0.002). Conclusion Extravasation of CM results in mild to moderate adverse effects in all cases. Our study suggests that patients with cardiac disease are more predisposed to contrast extravasation than others. Further and larger studies are needed to confirm this trend. PMID:26090047

  1. Varied incidence of immediate adverse reactions to low-osmolar non-ionic iodide radiocontrast media used in computed tomography.

    PubMed

    Kim, S R; Lee, J H; Park, K H; Park, H J; Park, J W

    2017-01-01

    Low-osmolar non-ionic radiocontrast media (RCMs) are commonly used throughout hospitals. However, the incidence of immediate adverse drug reactions (ADRs) to various low-osmolar non-ionic RCMs is not well studied. We compared the incidence of immediate ADRs among different low-osmolar non-ionic RCMs used in computed tomography (CT). Severance Hospital has collected data for adverse reactions occurring in-hospital using an internally developed system. Using this data, we reviewed 1969 immediate ADRs from 286 087 RCM-contrasted CT examinations of 142 099 patients and compared the immediate ADRs of iobitridol, iohexol, iopamidol, and iopromide. We analysed the incidence of immediate ADRs to different RCMs, as well as the effect of single or multiple CT examinations per day. Iopromide showed the highest incidence of immediate ADRs (1.03%) and was followed by iopamidol (0.67%), iohexol (0.64%), and iobitridol (0.34%). In cases of anaphylaxis, iopromide also showed the highest incidence (0.041%), followed by iopamidol (0.023%), iohexol (0.018%), and iobitridol (0.012%). Risk of immediate ADR due to multiple CT examinations (1.19%) was significantly higher than the risk due to a single CT examination (0.63%). Risk of anaphylaxis was also higher for multiple CT examinations (0.052%) than for a single CT examination (0.020%). The incidence of immediate ADRs varied according to the low-osmolar non-ionic RCM used. Iopromide-induced immediate ADRs were more frequent, while iobitridol was associated with fewer immediate ADRs than other RCMs. Multiple CT examinations per day resulted in a higher incidence of immediate ADRs and anaphylaxis than a single CT examination. Clinicians should consider these risk differences of immediate ADRs when prescribing contrasted CT examinations. © 2016 The Authors. Clinical & Experimental Allergy Published by John Wiley & Sons Ltd.

  2. Use of CT Hounsfield unit density to identify ablated tumor after laparoscopic radiofrequency ablation of hepatic tumors.

    PubMed

    Berber, E; Foroutani, A; Garland, A M; Rogers, S J; Engle, K L; Ryan, T L; Siperstein, A E

    2000-09-01

    When attempting to interpret CT scans after radiofrequency thermal ablation (RFA) of liver tumors, it is sometimes difficult to distinguish ablated from viable tumor tissue. Identification of the two types of tissue is specially problematic for lesions that are hypodense before ablation. The aim of this study was to determine whether quantitative Hounsfield unit (HU) density measurements can be used to document the lack of tumor perfusion and thereby identify ablated tissue. Liver spiral CT scans of 13 patients with 51 lesions undergoing laparoscopic RFA for metastatic liver tumors within a 2-year time period were reviewed. HU density of the lesions as well as normal liver were measured pre- and postoperatively in each CT phase (noncontrast, arterial, portovenous). Statistical analyses were performed using Student's paired t-test and ANOVA. Normal liver parenchyma, which was used as a control, showed a similar increase with contrast injection in both pre- and postprocedure CT scans (56.4 +/- 2.4 vs 57.1 +/- 2.4 HU, respectively; p = 0.3). In contrast, ablated liver lesions showed a preablation increase of 45.7 +/- 3.4 HU but only a minimal postablation increase of 6.6 +/- 0.7 HU (p < 0.0001). This was true for highly vascular tumors (neuroendocrine) as well as hypovascular ones (adenocarcinoma). This is the first study to define quantitative radiological criteria using HU density for the evaluation of ablated tissues. A lack of increase in HU density with contrast injection indicates necrotic tissue, whereas perfused tissue shows an increase in HU density. This technique can be used in the evaluation of patients undergoing RFA.

  3. Enteral Contrast in the Computed Tomography Diagnosis of Appendicitis

    PubMed Central

    Drake, Frederick Thurston; Alfonso, Rafael; Bhargava, Puneet; Cuevas, Carlos; Dighe, Manjiri K.; Florence, Michael G.; Johnson, Morris G.; Jurkovich, Gregory J.; Steele, Scott R.; Symons, Rebecca Gaston; Thirlby, Richard C.; Flum, David R.

    2014-01-01

    Objective Our goal was to perform a comparative effectiveness study of intravenous (IV)-only versus IV + enteral contrast in computed tomographic (CT) scans performed for patients undergoing appendectomy across a diverse group of hospitals. Background Small randomized trials from tertiary centers suggest that enteral contrast does not improve diagnostic performance of CT for suspected appendicitis, but generalizability has not been demonstrated. Eliminating enteral contrast may improve efficiency, patient comfort, and safety. Methods We analyzed data for adult patients who underwent nonelective appendectomy at 56 hospitals over a 2-year period. Data were obtained directly from patient charts by trained abstractors. Multivariate logistic regression was utilized to adjust for potential confounding. The main outcome measure was concordance between final radiology interpretation and final pathology report. Results A total of 9047 adults underwent appendectomy and 8089 (89.4%) underwent CT, 54.1% of these with IV contrast only and 28.5% with IV + enteral contrast. Pathology findings correlated with radiographic findings in 90.0% of patients who received IV + enteral contrast and 90.4% of patients scanned with IV contrast alone. Hospitals were categorized as rural or urban and by their teaching status. Regardless of hospital type, there was no difference in concordance between IV-only and IV + enteral contrast. After adjusting for age, sex, comorbid conditions, weight, hospital type, and perforation, odds ratio of concordance for IV + enteral contrast versus IV contrast alone was 0.95 (95% CI: 0.72–1.25). Conclusions Enteral contrast does not improve CT evaluation of appendicitis in patients undergoing appendectomy. These broadly generalizable results from a diverse group of hospitals suggest that enteral contrast can be eliminated in CT scans for suspected appendicitis. PMID:24598250

  4. Modeling patterns of anatomical deformations in prostate patients undergoing radiation therapy with an endorectal balloon

    NASA Astrophysics Data System (ADS)

    Brion, Eliott; Richter, Christian; Macq, Benoit; Stützer, Kristin; Exner, Florian; Troost, Esther; Hölscher, Tobias; Bondar, Luiza

    2017-03-01

    External beam radiation therapy (EBRT) treats cancer by delivering daily fractions of radiation to a target volume. For prostate cancer, the target undergoes day-to-day variations in position, volume, and shape. For stereotactic photon and for proton EBRT, endorectal balloons (ERBs) can be used to limit variations. To date, patterns of non-rigid variations for patients with ERB have not been modeled. We extracted and modeled the patient-specific patterns of variations, using regularly acquired CT-images, non-rigid point cloud registration, and principal component analysis (PCA). For each patient, a non-rigid point-set registration method, called Coherent Point Drift, (CPD) was used to automatically generate landmark correspondences between all target shapes. To ensure accurate registrations, we tested and validated CPD by identifying parameter values leading to the smallest registration errors (surface matching error 0.13+/-0.09 mm). PCA demonstrated that 88+/-3.2% of the target motion could be explained using only 4 principal modes. The most dominant component of target motion is a squeezing and stretching in the anterior-posterior and superior-inferior directions. A PCA model of daily landmark displacements, generated using 6 to 10 CT-scans, could explain well the target motion for the CT-scans not included in the model (modeling error decreased from 1.83+/-0.8 mm for 6 CT-scans to 1.6+/-0.7 mm for 10 CT-scans). PCA modeling error was smaller than the naive approximation by the mean shape (approximation error 2.66+/-0.59 mm). Future work will investigate the use of the PCA-model to improve the accuracy of EBRT techniques that are highly susceptible to anatomical variations such as, proton therapy

  5. [Application of computed tomography (CT) examination for forensic medicine].

    PubMed

    Urbanik, Andrzej; Chrzan, Robert

    2013-01-01

    The aim of the study is to present a own experiences in usage of post mortem CT examination for forensic medicine. With the help of 16-slice CT scanner 181 corpses were examined. Obtained during acquisition imaging data are later developed with dedicated programmes. Analyzed images were extracted from axial sections, multiplanar reconstructions as well as 3D reconstructions. Gained information helped greatly when classical autopsy was performed by making it more accurate. A CT scan images recorded digitally enable to evaluate corpses at any time, despite processes of putrefaction or cremation. If possible CT examination should precede classical autopsy.

  6. Geometry-constraint-scan imaging for in-line phase contrast micro-CT.

    PubMed

    Fu, Jian; Yu, Guangyuan; Fan, Dekai

    2014-01-01

    X-ray phase contrast computed tomography (CT) uses the phase shift that x-rays undergo when passing through matter, rather than their attenuation, as the imaging signal and may provide better image quality in soft-tissue and biomedical materials with low atomic number. Here a geometry-constraint-scan imaging technique for in-line phase contrast micro-CT is reported. It consists of two circular-trajectory scans with x-ray detector at different positions, the phase projection extraction method with the Fresnel free-propagation theory and the filter back-projection reconstruction algorithm. This method removes the contact-detector scan and the pure phase object assumption in classical in-line phase contrast Micro-CT. Consequently it relaxes the experimental conditions and improves the image contrast. This work comprises a numerical study of this technique and its experimental verification using a biomedical composite dataset measured at an x-ray tube source Micro-CT setup. The numerical and experimental results demonstrate the validity of the presented method. It will be of interest for a wide range of in-line phase contrast Micro-CT applications in biology and medicine.

  7. PET/CT aids the staging of and radiotherapy planning for early-stage extranodal natural killer/T-cell lymphoma, nasal type: A case series

    PubMed Central

    2011-01-01

    Extranodal natural killer/T-cell lymphoma (ENKTL), nasal type, is a rare form of non-Hodgkin lymphoma. Treatment of ENKTL primarily relies on radiation; thus, proper delineation of target volumes is critical. Currently, the ideal modalities for delineation of gross tumor volume for ENKTL are unknown. We describe three consecutive cases of localized ENKTL that presented to the Nova Scotia Cancer Centre in Halifax, Nova Scotia. All patients had a planning CT and MRI as well as a planning FDG-PET/CT in the radiotherapy treatment position, wearing immobilization masks. All patients received radiation alone. In two patients, PET/CT changed not only the stage, but also the target volume requiring treatment. The third patient was unable to tolerate an MRI, but was able to undergo PET/CT, which improved the accuracy of the target volume. PET/CT aided the staging of and radiotherapy planning for our patients and appears to be a promising tool in the treatment of ENKTL. PMID:22208903

  8. Analysis of FET-PET imaging for target volume definition in patients with gliomas treated with conformal radiotherapy.

    PubMed

    Rieken, Stefan; Habermehl, Daniel; Giesel, Frederik L; Hoffmann, Christoph; Burger, Ute; Rief, Harald; Welzel, Thomas; Haberkorn, Uwe; Debus, Jürgen; Combs, Stephanie E

    2013-12-01

    Modern radiotherapy (RT) techniques such as stereotactic RT, intensity-modulated RT, or particle irradiation allow local dose escalation with simultaneous sparing of critical organs. Several trials are currently investigating their benefit in glioma reirradiation and boost irradiation. Target volume definition is of critical importance especially when steep dose gradient techniques are employed. In this manuscript we investigate the impact of O-(2-(F-18)fluoroethyl)-l-tyrosine-positron emission tomography/computer tomography (FET-PET/CT) on target volume definition in low and high grade glioma patients undergoing either first or re-irradiation with particles. We investigated volumetric size and uniformity of magnetic resonance imaging (MRI)- vs. FET-PET/CT-derived gross tumor volumes (GTVs) and planning target volumes (PTVs) of 41 glioma patients. Clinical cases are presented to demonstrate potential benefits of integrating FET-PET/CT-planning into daily routine. Integrating FET-uptake into the delineation of GTVs yields larger volumes. Combined modality-derived PTVs are significantly enlarged in high grade glioma patients and in case of primary RT. The congruence of MRI and FET signals for the identification of glioma GTVs is poor with mean uniformity indices of 0.39. MRI-based PTVs miss 17% of FET-PET/CT-based GTVs. Non significant alterations were detected in low grade glioma patients and in those undergoing reirradiation. Target volume definition for malignant gliomas during initial RT may yield significantly differing results depending upon the imaging modality, which the contouring process is based upon. The integration of both MRI and FET-PET/CT may help to improve GTV coverage by avoiding larger incongruences between physical and biological imaging techniques. In low grade gliomas and in cases of reirradiation, more studies are needed in order to investigate a potential benefit of FET-PET/CT for planning of RT. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  9. Segmentation algorithm of colon based on multi-slice CT colonography

    NASA Astrophysics Data System (ADS)

    Hu, Yizhong; Ahamed, Mohammed Shabbir; Takahashi, Eiji; Suzuki, Hidenobu; Kawata, Yoshiki; Niki, Noboru; Suzuki, Masahiro; Iinuma, Gen; Moriyama, Noriyuki

    2012-02-01

    CT colonography is a radiology test that looks at people's large intestines(colon). CT colonography can screen many options of colon cancer. This test is used to detect polyps or cancers of the colon. CT colonography is safe and reliable. It can be used if people are too sick to undergo other forms of colon cancer screening. In our research, we proposed a method for automatic segmentation of the colon from abdominal computed Tomography (CT) images. Our multistage detection method extracted colon and spited colon into different parts according to the colon anatomy information. We found that among the five segmented parts of the colon, sigmoid (20%) and rectum (50%) are more sensitive toward polyps and masses than the other three parts. Our research focused on detecting the colon by the individual diagnosis of sigmoid and rectum. We think it would make the rapid and easy diagnosis of colon in its earlier stage and help doctors for analysis of correct position of each part and detect the colon rectal cancer much easier.

  10. AN ANALYSIS OF THE POTENTIAL ROLE OF CHEST TOMOSYNTHESIS IN OPTIMISING IMAGING RESOURCES IN THORACIC RADIOLOGY

    PubMed Central

    Petersson, Cecilia; Båth, Magnus; Vikgren, Jenny; Johnsson, Åse Allansdotter

    2016-01-01

    The aim of the study was to investigate the potential role of chest tomosynthesis (CTS) at a tertiary referral centre by exploring to what extent CTS could substitute chest radiography (CXR) and computed tomography (CT). The study comprised 1433 CXR, 523 CT and 216 CTS examinations performed 5 years after the introduction of CTS. For each examination, it was decided if CTS would have been appropriate instead of CXR (CXR cases), if CTS could have replaced the performed CT (CT cases) or if CT would have been performed had CTS not been available (CTS cases). It was judged that (a) CTS had been appropriate in 15 % of the CXR examinations, (b) CTS could have replaced additionally 7 % of the CT examinations and (c) CT would have been carried out in 63 % of the performed CTS examinations, had CTS not been available. In conclusion, the potential role for CTS to substitute other modalities during office hours at a tertiary referral centre may be in the order of 20 and 25 % of performed CXR and chest CT, respectively. PMID:26979807

  11. Evaluation of Kidney Stones with Reduced-Radiation Dose CT: Progress from 2011-2012 to 2015-2016-Not There Yet.

    PubMed

    Weisenthal, Karrin; Karthik, Priyadarshini; Shaw, Melissa; Sengupta, Debapriya; Bhargavan-Chatfield, Mythreyi; Burleson, Judy; Mustafa, Adel; Kalra, Mannudeep; Moore, Christopher

    2018-02-01

    Purpose To determine if the use of reduced-dose computed tomography (CT) for evaluation of kidney stones increased in 2015-2016 compared with that in 2011-2012, to determine variability in radiation exposure according to facility for this indication, and to establish a current average radiation dose for CT evaluation for kidney stones by querying a national dose registry. Materials and Methods This cross-sectional study was exempt from institutional review board approval. Data were obtained from the American College of Radiology dose registry for CT examinations submitted from July 2015 to June 2016. Study descriptors consistent with single-phase unenhanced CT for evaluation of kidney stones and associated RadLex® Playbook identifiers (RPIDs) were retrospectively identified. Facilities actively submitting data on kidney stone-specific CT examinations were included. Dose metrics including volumetric CT dose index, dose-length product, and size-specific dose estimate, when available, were reported, and a random effects model was run to account for clustering of CT examinations at facilities. A z-ratio was calculated to test for a significant difference between the proportion of reduced-radiation dose CT examinations (defined as those with a dose-length product of 200 mGy · cm or less) performed in 2015-2016 and the proportion performed in 2011-2012. Results Three hundred four study descriptors for kidney stone CT corresponding to data from 328 facilities that submitted 105 334 kidney stone CT examinations were identified. Reduced-dose CT examinations accounted for 8040 of 105 334 (7.6%) CT examinations, a 5.6% increase from the 1010 of 49 903 (2%) examinations in 2011-2012 (P < .001). Mean overall dose-length product was 689 mGy · cm (95% confidence interval: 667, 712), decreased from the mean of 746 mGy · cm observed in 2011-2012. Median facility dose-length product varied up to sevenfold, from less than 200 mGy · cm to greater than 1600 mGy · cm. Conclusion Use of reduced-radiation dose CT for evaluation of kidney stones has increased since 2011-2012, but remains low; variability of radiation dose according to facility continues to be wide. National mean CT radiation exposure for evaluation of renal colic during 2015-2016 decreased relative to 2011-2012 values, but remained well above what is reasonably achievable. © RSNA, 2017.

  12. Blunt trauma of bone structures of the chest--computed tomography vs multidetector computed tomography.

    PubMed

    Petrović, Kosta; Turkalj, Ivan; Stojanović, Sanja; Vucaj-Cirilović, Viktorija; Nikolić, Olivera; Stojiljković, Dragana

    2013-08-01

    Computerized tomography (CT), especially multidetector CT (MDCT), has had a revolutionary impact in diagnostic in traumatized patients. The aim of the study was to identify and compare the frequency of injuries to bone structures of the thorax displayed with 5-mm-thick axial CT slices and thin-slice (MDCT) examination with the use of 3D reconstructions, primarily multiplanar reformations (MPR). This prospective study included 61 patients with blunt trauma submitted to CT scan of the thorax as initial assessment. The two experienced radiologists inde pendently and separately described the findings for 5-mm-thick axial CT slices (5 mm CT) as in monoslice CT examination; MPR and other 3D reconstructions along with thin-slice axial sections which were available in modern MDCT technologies. After describing thin-slice examination in case of disagreement in the findings, the examiners redescribed thin-slice examination together which was ultimately considered as a real, true finding. No statistically significant difference in interobserver evaluation of 5 mm CT examination was recorded (p > 0.05). Evaluation of fractures of sternum with 5 mm CT and MDCT showed a statistically significant difference (p < 0.05) in favor of better display of injury by MDCT examination. MDCT is a powerful diagnostic tool that can describe higher number of bone fractures of the chest in traumatized patients compared to 5 mm CT, especially in the region of sternum for which a statistical significance was obtained using MPR. Moreover, the importance of MDCT is also set by easier and more accurate determination of the level of bone injury.

  13. Is triple contrast computed tomographic scanning useful in the selective management of stab wounds to the back?

    PubMed

    McAllister, E; Perez, M; Albrink, M H; Olsen, S M; Rosemurgy, A S

    1994-09-01

    We devised a protocol to prospectively manage stab wounds to the back with the hypothesis that the triple contrast computed tomographic (CT) scan is an effective means of detecting occult injury in these patients. All wounds to the back in hemodynamically stable adults were locally explored. All patients with muscular fascial penetration underwent triple contrast CT scanning utilizing oral, rectal, and IV contrast. Patients did not undergo surgical exploration if their CT scan was interpreted as negative or if the CT scan demonstrated injuries not requiring surgical intervention. Fifty-three patients were entered into the protocol. The time to complete the triple contrast CT scan ranged from 3 to 6 hours at a cost of $1050 for each scan. In 51 patients (96%), the CT scan either had negative findings (n = 31) or showed injuries not requiring exploration (n = 20). These patients did well with nonsurgical management. Two CT scans documented significant injury and led to surgical exploration and therapeutic celiotomies. Although triple contrast CT scanning was able to detect occult injury in patients with stab wounds to the back it did so at considerable cost and the results rarely altered clinical care. Therefore, its routine use in these patients is not recommended.

  14. Transcatheter Arterial Embolization of Concurrent Spontaneous Hematomas of the Rectus Sheath and Psoas Muscle in Patients Undergoing Anticoagulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Basile, Antonio; Medina, Jose Garcia; Mundo, Elena

    We report a case of concurrent rectus sheath and psoas hematomas in a patient undergoing anticoagulant therapy, treated by transcatheter arterial embolization (TAE) of inferior epigastric and lumbar arteries. Computed tomography (CT) demonstrated signs of active bleeding in two hematomas of the anterior and posterior abdominal walls. Transfemoral arteriogram confirmed the extravasation of contrast from the right inferior epigastric artery (RIEA). Indirect signs of bleeding were also found in a right lumbar artery (RLA). We successfully performed TAE of the feeding arteries. There have been few reports in the literature of such spontaneous hemorrhages in patients undergoing anticoagulation, successfully treatedmore » by TAE.« less

  15. CT abdominal imaging findings in patients with sickle cell disease: acute vaso-occlusive crisis, complications, and chronic sequelae.

    PubMed

    Gardner, Carly S; Boll, Daniel T; Bhosale, Priya; Jaffe, Tracy A

    2016-12-01

    Sickle cell disease (SCD) is the most prevalent hemoglobinopathy. Survival in patients with SCD has improved over the past few decades. These patients experience a lifetime of repeated acute pain crises, which are thought to result from sickling and microvascular occlusions; acute abdominal pain is common. Moreover, repeated crises often lead to organ dysfunction, such as asplenia, hepatic failure, and renal failure. The spleen, liver, biliary system, kidneys, and gastrointestinal tract can all be affected. Patients may undergo CT to further direct clinical management. We review the spectrum of CT imaging findings of abdominal manifestations in patients with SCD, from the acute microvascular occlusive pain crisis to the potential complications and chronic sequelae.

  16. Cervical spine evaluation and clearance in the intoxicated patient: A prospective Western Trauma Association Multi-Institutional Trial and Survey.

    PubMed

    Martin, Matthew J; Bush, Lisa D; Inaba, Kenji; Byerly, Saskya; Schreiber, Martin; Peck, Kimberly A; Barmparas, Galinos; Menaker, Jay; Hazelton, Joshua P; Coimbra, Raul; Zielinski, Martin D; Brown, Carlos V R; Ball, Chad G; Cherry-Bukowiec, Jill R; Burlew, Clay Cothren; Dunn, Julie; Minshall, C Todd; Carrick, Matthew M; Berg, Gina M; Demetriades, Demetrios; Long, William

    2017-12-01

    Intoxication often prevents clinical clearance of the cervical spine (Csp) after trauma leading to prolonged immobilization even with a normal computed tomography (CT) scan. We evaluated the accuracy of CT at detecting clinically significant Csp injury, and surveyed participants on related opinions and practice. A prospective multicenter study (2013-2015) at 17 centers. All adult blunt trauma patients underwent structured clinical examination and imaging including a Csp CT, with follow-up thru discharge. alcohol- and drug-intoxicated patients (TOX+) were identified by serum and/or urine testing. Primary outcomes included the incidence and type of Csp injuries, the accuracy of CT scan, and the impact of TOX+ on the time to Csp clearance. A 36-item survey querying local protocols, practices, and opinions in the TOX+ population was administered. Ten thousand one hundred ninety-one patients were prospectively enrolled and underwent CT Csp during the initial trauma evaluation. The majority were men (67%), had vehicular trauma or falls (83%), with mean age of 48 years, and mean Injury Severity Score (ISS) of 11. The overall incidence of Csp injury was 10.6%. TOX+ comprised 30% of the cohort (19% EtOH only, 6% drug only, and 5% both). TOX+ were significantly younger (41 years vs. 51 years; p < 0.01) but with similar mean Injury Severity Score (11) and Glasgow Coma Scale score (13). The TOX+ cohort had a lower incidence of Csp injury versus nonintoxicated (8.4% vs. 11.5%; p < 0.01). In the TOX+ group, CT had a sensitivity of 94%, specificity of 99.5%, and negative predictive value (NPV) of 99.5% for all Csp injuries. For clinically significant injuries, the NPV was 99.9%, and there were no unstable Csp injuries missed by CT (NPV, 100%). When CT Csp was negative, TOX+ led to longer immobilization versus sober patients (mean, 8 hours vs. 2 hours; p < 0.01), and prolonged immobilization (>12 hrs) in 25%. The survey showed marked variations in protocols, definitions, and Csp clearance practices among participating centers, although 100% indicated willingness to change practice based on these data. For intoxicated patients undergoing Csp imaging, CT scan was highly accurate and reliable for identifying clinically significant spine injuries, and had a 100% NPV for identifying unstable injuries. CT-based clearance in TOX+ patients appears safe and may avoid unnecessary prolonged immobilization. There was wide disparity in practices, definitions, and opinions among the participating centers. Diagnostic tests or criteria, level II.

  17. Diagnostic role of magnetic resonance imaging in assessing orofacial pain and paresthesia.

    PubMed

    Ohba, Seigo; Yoshimura, Hitoshi; Matsuda, Shinpei; Kobayashi, Junichi; Kimura, Takashi; Aiki, Minako; Sano, Kazuo

    2014-09-01

    The aim of this study was to compare the efficacy of CT and MRI in evaluating orofacial pain and paresthesia. A total of 96 patients with orofacial pain and/or paresthesia were included in this study. The patients who underwent CT and/or MRI examinations were assessed, and the efficacy of CT and/or MRI examinations in detecting the causative disease of the orofacial pain and paresthesia was evaluated. Seventy (72.9%) of 96 patients underwent CT and/or MRI examinations. Whereas CT examinations detected 2 diseases (4.5%) in 44 tests, 13 diseases (37.1%) were detected in 35 MRI examinations. Seven (53.8%) of 13 diseases, which were detected by MRI, were found in elderly patients. A high percentage of patients, who claimed orofacial pain and paresthesia, have other diseases in their brain, especially in elderly patients, and MRI is more useful than CT for evaluating these patients.

  18. Ehrlichia Meningitis Mimicking Aneurysmal Subarachnoid Hemorrhage: A Case Study for Medical Decision-Making Heuristics.

    PubMed

    Dredla, Brynn; Freeman, William D

    2016-04-01

    Thunderclap headache is a sudden and severe headache that can occur after an aneurysmal subarachnoid hemorrhage (SAH). Subarachnoid hemorrhage is a medical emergency that requires prompt attention and hospitalization. Patients with thunderclap headache often undergo a noncontrast head computed tomography (CT) scan to ascertain SAH bleeding and, if the scan is negative, then undergo a lumbar puncture to look for cerebrospinal fluid (CSF) red blood cells (RBCs), which would be consistent with an aneurysmal leak. If the initial CT is negative and CSF is positive for RBCs, patients are usually admitted to the hospital for evaluation of intracranial aneurysm. We encountered a patient with thunderclap headache whose initial head CT was negative for SAH and whose CSF tested positive for RBCs. The patient was referred to our center for evaluation and management of aneurysmal SAH. However, on careful review of the patient's medical history, serum laboratory values, and spinal fluid values, the patient was diagnosed with Ehrlichia chaffeensis meningitis. While Ehrlichia meningitis is rare, it is important to recognize the clinical clues that could help avoid formal cerebral angiography, a costly and potentially unnecessary procedure. We present how this case represented a cognitive framing bias and anchoring heuristic as well as steps that medical providers can use to prevent such cognitive errors in diagnosis.

  19. The effective dose result of 18F-FDG PET-CT paediatric patients

    NASA Astrophysics Data System (ADS)

    Hussin, D.; Said, M. A.; Ali, N. S.; Tajuddin, A. A.; Zainon, R.

    2017-05-01

    Paediatric patient received high exposure from both CT and PET examination. Automatic Exposure Control (AEC) is important in CT dose reduction. This study aimed to compare the effective dose obtained from PET-CT scanner with and without the use of AEC function. In this study, 68 patients underwent PET-CT examination without the use of AEC function, while 25 patients used the AEC function during the examination. Patients involved in this study were between 2 to 15 years old with varies of malignancies and epilepsy diseases. The effective dose obtained from PET and CT examinations was calculated based on recommendation from International Commission on Radiological Protection (ICRP) Publication 106 and ICRP publication 102. The outcome of this study shows that the radiation dose was reduced up to 20% with the use of AEC function. The mean average of effective dose result obtained from PET and CT examinations without the use of AEC and AEC function were found to be as 6.67 mSv, 6.77 mSv, 6.03mSv and 4.96 mSv respectively. Where total effective dose result of PET-CT with non-AEC and AEC were found to be 13.44 mSv and 10.99 mSv respectively. Conclusion of this study is, the installation of AEC function in PET-CT machine does play important role in CT dose reduction especially for paediatric patient.

  20. Effect of emergency department CT on neuroimaging case volume and positive scan rates.

    PubMed

    Oguz, Kader Karli; Yousem, David M; Deluca, Tom; Herskovits, Edward H; Beauchamp, Norman J

    2002-09-01

    The authors performed this study to determine the effect a computed tomographic (CT) scanner in the emergency department (ED) has on neuroimaging case volume and positive scan rates. The total numbers of ED visits and neuroradiology CT scans requested from the ED were recorded for 1998 and 2000, the years before and after the installation of a CT unit in the ED. For each examination type (brain, face, cervical spine), studies were graded for major findings (those that affected patient care), minor findings, and normal findings. The CT utilization rates and positive study rates were compared for each type of study performed for both years. There was a statistically significant increase in the utilization rate after installation of the CT unit (P < .001). The fractions of studies with major findings, minor findings, and normal findings changed significantly after installation of the CT unit for facial examinations (P = .002) but not for brain (P = .12) or cervical spine (P = .24) examinations. In all types of studies, the percentage of normal examinations increased. In toto, there was a significant decrease in the positive scan rate after installation of the CT scanner (P = .004). After installation of a CT scanner in the ED, there was increased utilization and a decreased rate of positive neuroradiologic examinations, the latter primarily due to lower positive rates for facial CT scans.

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    De Ornelas-Couto, M; Bossart, E; Elsayyad, N

    Purpose: To determine the sensitivity of dose-mass-histogram (DMH) due to anatomical changes of head-and-neck squamous cell carcinoma (HNSCC) radiotherapy (RT). Methods: Eight patients undergoing RT treatment for HNSCC were scanned during the third and sixth week of RT. These second (CT2) and third (CT3) CTs were co-registered to the planning CT (CT1). Contours were propagated via deformable registration from CT1 and doses were re-calculated. DMHs were extracted for each CT set. DMH sensitivity was assessed by dose-mass indices (DMIs), which represent the dose delivered to a certain mass of and anatomical structure. DMIs included: dose to 98%, 95% and 2%more » of the target masses (PTV1, PTV2, and PTV3) and organs-at-risk (OARs): cord DMI2%, brainstem DMI2%, left- and right-parotid DMI2% and DMI50%, and mandible DMI2%. A two-tailed paired t-test was used to compare changes to DMIs in CT2 and CT3 with respect to CT1 (CT2/CT1 and CT3/CT1). Results: Changes to DMHs were found for all OARs and PTVs, but they were significant only for the PTVs. Maximum dose to PTVs increased significantly for CT2/CT1 in all three PTVs, but CT3/CT1 changes were only significantly different for PTV1 and PTV2. Dose coverage to the three PTVs was also significantly different, DMI98% was lower for both CT2/CT1 and CT3/CT1. DMI95% was significantly lower for PTV1 for CT2/CT1, PTV2 for CT2/CT1 and CT3/CT1, and PTV3 for CT3/CT1. Conclusion: Changes in anatomy significantly change dose-mass coverage for the planning targets, making it necessary to re-plan in order to maintain the therapeutic goals. Maximum dose to the PTVs increase significantly as RT progresses, which may not be problematic as long as the high dose remains in the gross tumor volume. Doses to OARs were minimally affected and the differences were not significant.« less

  2. Patient-specific lean body mass can be estimated from limited-coverage computed tomography images.

    PubMed

    Devriese, Joke; Beels, Laurence; Maes, Alex; van de Wiele, Christophe; Pottel, Hans

    2018-06-01

    In PET/CT, quantitative evaluation of tumour metabolic activity is possible through standardized uptake values, usually normalized for body weight (BW) or lean body mass (LBM). Patient-specific LBM can be estimated from whole-body (WB) CT images. As most clinical indications only warrant PET/CT examinations covering head to midthigh, the aim of this study was to develop a simple and reliable method to estimate LBM from limited-coverage (LC) CT images and test its validity. Head-to-toe PET/CT examinations were retrospectively retrieved and semiautomatically segmented into tissue types based on thresholding of CT Hounsfield units. LC was obtained by omitting image slices. Image segmentation was validated on the WB CT examinations by comparing CT-estimated BW with actual BW, and LBM estimated from LC images were compared with LBM estimated from WB images. A direct method and an indirect method were developed and validated on an independent data set. Comparing LBM estimated from LC examinations with estimates from WB examinations (LBMWB) showed a significant but limited bias of 1.2 kg (direct method) and nonsignificant bias of 0.05 kg (indirect method). This study demonstrates that LBM can be estimated from LC CT images with no significant difference from LBMWB.

  3. Plateletworks platelet function test compared to the thromboelastograph for prediction of postoperative outcomes.

    PubMed

    Ostrowsky, Jacob; Foes, Jennifer; Warchol, Mark; Tsarovsky, Gary; Blay, Jessica

    2004-06-01

    Approximately 3.5 million units of platelets are transfused in the United States each year to patients undergoing open-heart surgery with cardiopulmonary bypass (CPB). CPB is a known contributor to platelet loss and platelet dysfunction leading to disruption of hemostasis. Impaired hemostasis results in excess bleeding in 5-25% of all patients undergoing CPB. For this reason, it may be beneficial to measure platelet number and function in these patients. The purpose of this study was to compare the Plateletworks platelet function analyzer to the thromboelastograph (TEG) in predicting postoperatiave hemostatic outcomes as measured by blood product use and chest tube (CT) drainage. This study consisted of 35 adult patients undergoing cardiac surgery with cardiopulmonary bypass at Rush-Presbyterian-Saint Luke's Medical Center (RPSLMC). The Plateletworks and TEG tests were performed preoperatively, after protamine was given, and 24 hours postoperatively on all patients. Plateletworks demonstrated a statistically significant change in platelet function as shown by the adenosine diphosphate (ADP) reagent tube from the preoperative period to the removal of the aortic cross clamp (p = .011). The TEG did not demonstrate a significant change in the k-time and maximum amplitude (MA), but did show a significant change in the alpha-angle from the pre-operative to postoperatiave sample (p = .035). A correlation was found between Plateletworks collagen reagent tubes preoperatively and CT drainage (p = .048, r -0.324). No statistical correlation was established between TEG parameters and CT drainage at any time interval. TEG preoperative MA showed a correlation to receipt of blood products (p = .016). When comparing the Plateletworks to the TEG in this study, the Plateletworks system was a more useful predictor of blood product use and chest tube drainage.

  4. Diagnostic Yield of Recommendations for Chest CT Examination Prompted by Outpatient Chest Radiographic Findings

    PubMed Central

    Harvey, H. Benjamin; Gilman, Matthew D.; Wu, Carol C.; Cushing, Matthew S.; Halpern, Elkan F.; Zhao, Jing; Pandharipande, Pari V.; Shepard, Jo-Anne O.

    2015-01-01

    Purpose To evaluate the diagnostic yield of recommended chest computed tomography (CT) prompted by abnormalities detected on outpatient chest radiographic images. Materials and Methods This HIPAA-compliant study had institutional review board approval; informed consent was waived. Reports of all outpatient chest radiographic examinations performed at a large academic center during 2008 (n = 29 138) were queried to identify studies that included a recommendation for a chest CT imaging. The radiology information system was queried for these patients to determine if a chest CT examination was obtained within 1 year of the index radiographic examination that contained the recommendation. For chest CT examinations obtained within 1 year of the index chest radiographic examination and that met inclusion criteria, chest CT images were reviewed to determine if there was an abnormality that corresponded to the chest radiographic finding that prompted the recommendation. All corresponding abnormalities were categorized as clinically relevant or not clinically relevant, based on whether further work-up or treatment was warranted. Groups were compared by using t test and Fisher exact test with a Bonferroni correction applied for multiple comparisons. Results There were 4.5% (1316 of 29138 [95% confidence interval {CI}: 4.3%, 4.8%]) of outpatient chest radiographic examinations that contained a recommendation for chest CT examination, and increasing patient age (P < .001) and positive smoking history (P = .001) were associated with increased likelihood of a recommendation for chest CT examination. Of patients within this subset who met inclusion criteria, 65.4% (691 of 1057 [95% CI: 62.4%, 68.2%) underwent a chest CT examination within the year after the index chest radiographic examination. Clinically relevant corresponding abnormalities were present on chest CT images in 41.4% (286 of 691 [95% CI: 37.7%, 45.2%]) of cases, nonclinically relevant corresponding abnormalities in 20.6% (142 of 691 [95% CI: 17.6%, 23.8%]) of cases, and no corresponding abnormalities in 38.1% (263 of 691 [95% CI: 34.4%, 41.8%]) of cases. Newly diagnosed, biopsy-proven malignancies were detected in 8.1% (56 of 691 [95% CI: 6.2%, 10.4%]) of cases. Conclusion A radiologist recommendation for chest CT to evaluate an abnormal finding on an outpatient chest radiographic examination has a high yield of clinically relevant findings. © RSNA, 2014 PMID:25531242

  5. [Postmortem CT examination in a case of alleged drowning--a case report].

    PubMed

    Woźniak, Krzysztof; Urbanik, Andrzej; Rzepecka-Woźniak, Ewa; Moskała, Artur; Kłys, Małgorzata

    2009-01-01

    The authors present an analysis of postmortem CT examination in a case of drowning in fresh water of a young male. Both the results of conventional forensic autopsy and radiologic examination have been compared. The analysis is illustrated by two-dimensional and three-dimensional reconstructions based on the DICOM files obtained during postmortem CT examination.

  6. Cardiac-CT and Cardiac-MR examinations cost analysis, based on data of four Italian Centers.

    PubMed

    Centonze, Maurizio; Lorenzin, Giuseppe; Francesconi, Andrea; Cademartiri, Filippo; Casagranda, Giulia; Fusaro, Michele; Ligabue, Guido; Zanetti, Giovanna; Spanti, Demetrio; De Cobelli, Francesco

    2016-01-01

    To establish the appropriate number of Cardiac-CT and Cardio-MR examinations, to determine an economically justified and sustainable investment in these two technologies, for an exclusive cardiologic use. From July 2013 to July 2014, through a survey in four different Italian Departments of Radiology, data on the costs of Cardiac-CT and Cardiac-MR examinations were collected. For the evaluation of the costs of examinations, it was used an analytical accounting system, considering only the direct costs (consumables, health personnel work time, equipment amortization/maintenance) and other costs (utilities, services, etc.). Indirect costs (general costs) were not assessed. It was made a simulation, assuming an exclusive use of the CT and MR equipments for Cardiac-CT and Cardiac-MR examinations, calculating the annual number necessary to arrive at the Break Even Point (BEP: the point at which cost or expenses and revenue are equal). On the basis of the CT costs, in order to reach the BEP, performing only Cardiac-CT examinations, an average of 2641-2752 examinations/year is needed. The annual time commitment of the Medical Professional to ensure the number of examinations to reach the BEP is 2625-2750 h/year, equivalent to two Medical Doctors in a Cardiology Department. The recent Cardiac-CT Italian Registry, in the period January-June 2011, reports a number of examinations of 3455 patients in 47 different Centers, distributed throughout the whole national territory. With regard to MR, in order to reach the BEP, performing only Cardiac-MR examinations, an average of 2435-3123 examinations/year is needed. The annual time commitment of the Medical Professional to ensure the number of examinations to reach the BEP is 2437-3125 h/year, equivalent to two Medical Doctors in a Cardiology Department. The recent Cardiac-MR Italian Registry reports a number of examinations of 3776 patients in 40 Centers, distributed throughout the whole national territory. This research has shown that, only on the basis of costs, currently in Italy is anti-economic an exclusive use of CT or MR equipment for cardiac exams, unless it's not decided, regardless of the recent guidelines and clinical indications, to submit all patients with cardiac diseases (diseases of the coronary arteries and cardiomyopathies) to Cardiac-CT and Cardiac-MR examinations. This might likely to increase both the inappropriate examinations and either health spending and in the case of CT with important repercussions, in terms of radio-exposure, subject to forensic procedures.

  7. A low-dose, dual-phase cardiovascular CT protocol to assess left atrial appendage anatomy and exclude thrombus prior to left atrial intervention.

    PubMed

    Lazoura, Olga; Ismail, Tevfik F; Pavitt, Christopher; Lindsay, Alistair; Sriharan, Mona; Rubens, Michael; Padley, Simon; Duncan, Alison; Wong, Tom; Nicol, Edward

    2016-02-01

    Assessment of the left atrial appendage (LAA) for thrombus and anatomy is important prior to atrial fibrillation (AF) ablation and LAA exclusion. The use of cardiovascular CT (CCT) to detect LAA thrombus has been limited by the high incidence of pseudothrombus on single-pass studies. We evaluated the diagnostic accuracy of a two-phase protocol incorporating a limited low-dose delayed contrast-enhanced examination of the LAA, compared with a single-pass study for LAA morphological assessment, and transesophageal echocardiography (TEE) for the exclusion of thrombus. Consecutive patients (n = 122) undergoing left atrial interventions for AF were assessed. All had a two-phase CCT protocol (first-past scan plus a limited, 60-s delayed scan of the LAA) and TEE. Sensitivity, specificity, diagnostic accuracy, positive (PPV) and negative predictive values (NPV) were calculated for the detection of true thrombus on first-pass and delayed scans, using TEE as the gold standard. Overall, 20/122 (16.4 %) patients had filling defects on the first-pass study. All affected the full delineation of the LAA morphology; 17/20 (85 %) were confirmed as pseudo-filling defects. Three (15 %) were seen on late-pass and confirmed as true thrombi on TEE; a significant improvement in diagnostic performance relative to a single-pass scan (McNemar Chi-square 17, p < 0.001). The sensitivity, specificity, diagnostic accuracy, PPV and NPV was 100, 85.7, 86.1, 15.0 and 100 % respectively for first-pass scans, and 100 % for all parameters for the delayed scans. The median (range) additional radiation dose for the delayed scan was 0.4 (0.2-0.6) mSv. A low-dose delayed scan significantly improves the identification of true LAA anatomy and thrombus in patients undergoing LA intervention.

  8. AN ANALYSIS OF THE POTENTIAL ROLE OF CHEST TOMOSYNTHESIS IN OPTIMISING IMAGING RESOURCES IN THORACIC RADIOLOGY.

    PubMed

    Petersson, Cecilia; Båth, Magnus; Vikgren, Jenny; Johnsson, Åse Allansdotter

    2016-06-01

    The aim of the study was to investigate the potential role of chest tomosynthesis (CTS) at a tertiary referral centre by exploring to what extent CTS could substitute chest radiography (CXR) and computed tomography (CT). The study comprised 1433 CXR, 523 CT and 216 CTS examinations performed 5 years after the introduction of CTS. For each examination, it was decided if CTS would have been appropriate instead of CXR (CXR cases), if CTS could have replaced the performed CT (CT cases) or if CT would have been performed had CTS not been available (CTS cases). It was judged that (a) CTS had been appropriate in 15 % of the CXR examinations, (b) CTS could have replaced additionally 7 % of the CT examinations and (c) CT would have been carried out in 63 % of the performed CTS examinations, had CTS not been available. In conclusion, the potential role for CTS to substitute other modalities during office hours at a tertiary referral centre may be in the order of 20 and 25 % of performed CXR and chest CT, respectively. © The Author 2016. Published by Oxford University Press.

  9. Bicuspid Aortic Valve Stenosis and the Effect of Vitamin K2 on Calcification Using 18F-Sodium Fluoride Positron Emission Tomography/Magnetic Resonance: The BASIK2 Rationale and Trial Design.

    PubMed

    Peeters, Frederique E C M; van Mourik, Manouk J W; Meex, Steven J R; Bucerius, Jan; Schalla, Simon M; Gerretsen, Suzanne C; Mihl, Casper; Dweck, Marc R; Schurgers, Leon J; Wildberger, Joachim E; Crijns, Harry J G M; Kietselaer, Bas L J H

    2018-03-21

    BASIK2 is a prospective, double-blind, randomized placebo-controlled trial investigating the effect of vitamin K2 (menaquinone-7;MK7) on imaging measurements of calcification in the bicuspid aortic valve (BAV) and calcific aortic valve stenosis (CAVS). BAV is associated with early development of CAVS. Pathophysiologic mechanisms are incompletely defined, and the only treatment available is valve replacement upon progression to severe symptomatic stenosis. Matrix Gla protein (MGP) inactivity is suggested to be involved in progression. Being a vitamin K dependent protein, supplementation with MK7 is a pharmacological option for activating MGP and intervening in the progression of CAVS. Forty-four subjects with BAV and mild-moderate CAVS will be included in the study, and baseline 18 F-sodiumfluoride ( 18 F-NaF) positron emission tomography (PET)/ magnetic resonance (MR) and computed tomography (CT) assessments will be performed. Thereafter, subjects will be randomized (1:1) to MK7 (360 mcg/day) or placebo. During an 18-month follow-up period, subjects will visit the hospital every 6 months, undergoing a second 18 F-NaF PET/MR after 6 months and CT after 6 and 18 months. The primary endpoint is the change in PET/MR 18 F-NaF uptake (6 months minus baseline) compared to this delta change in the placebo arm. The main secondary endpoints are changes in calcium score (CT), progression of the left ventricularremodeling response and CAVS severity (echocardiography). We will also examine the association between early calcification activity (PET) and later changes in calcium score (CT).

  10. Patient-specific dose estimation for pediatric abdomen-pelvis CT

    NASA Astrophysics Data System (ADS)

    Li, Xiang; Samei, Ehsan; Segars, W. Paul; Sturgeon, Gregory M.; Colsher, James G.; Frush, Donald P.

    2009-02-01

    The purpose of this study is to develop a method for estimating patient-specific dose from abdomen-pelvis CT examinations and to investigate dose variation across patients in the same weight group. Our study consisted of seven pediatric patients in the same weight/protocol group, for whom full-body computer models were previously created based on the patients' CT data obtained for clinical indications. Organ and effective dose of these patients from an abdomen-pelvis scan protocol (LightSpeed VCT scanner, 120-kVp, 85-90 mA, 0.4-s gantry rotation period, 1.375-pitch, 40-mm beam collimation, and small body scan field-of-view) was calculated using a Monte Carlo program previously developed and validated for the same CT system. The seven patients had effective dose of 2.4-2.8 mSv, corresponding to normalized effective dose of 6.6-8.3 mSv/100mAs (coefficient of variation: 7.6%). Dose variations across the patients were small for large organs in the scan coverage (mean: 6.6%; range: 4.9%-9.2%), larger for small organs in the scan coverage (mean: 10.3%; range: 1.4%-15.6%), and the largest for organs partially or completely outside the scan coverage (mean: 14.8%; range: 5.7%-27.7%). Normalized effective dose correlated strongly with body weight (correlation coefficient: r = -0.94). Normalized dose to the kidney and the adrenal gland correlated strongly with mid-liver equivalent diameter (kidney: r = -0.97; adrenal glands: r = -0.98). Normalized dose to the small intestine correlated strongly with mid-intestine equivalent diameter (r = -0.97). These strong correlations suggest that patient-specific dose may be estimated for any other child in the same size group who undergoes the abdomen-pelvis scan.

  11. Diagnosis, treatment and prognosis of small bowel volvulus in adults: A monocentric summary of a rare small intestinal obstruction.

    PubMed

    Li, Xiaohang; Zhang, Jialin; Li, Baifeng; Yi, Dehui; Zhang, Chengshuo; Sun, Ning; Lv, Wu; Jiao, Ao

    2017-01-01

    Small bowel volvulus is a rare disease, which is also challenging to diagnose. The aims of this study were to characterize the clinical and radiological features associated with small bowel volvulus and treatment and to identify risk factors for associated small bowel necrosis. Patients with small bowel volvulus who underwent operations from January 2001 to December 2015 at the First Affiliated Hospital of China Medical University (Shenyang, China) were reviewed. Clinical, surgical and postsurgical data were registered and analyzed. Thirty-one patients were included for analysis. Fifteen patients were female (48.4%), with an average age of 47.7 years (18-79 years). The clinical signs and symptoms were unspecific and resembled intestinal obstruction. Clinical examination revealed abdominal distension and/or diffuse tenderness with or without signs of peritonitis. The use of CT scans, X-rays or ultrasound did not differ significantly between patients. In 9 of 20 patients that received abdominal CT scans, "whirlpool sign" on the CT scan was present. Secondary small bowel volvulus was present in 58.1% of patients, and causes included bands (3), adhesion (7), congenital anomalies (7) and stromal tumor (1). Out of the 31 patients, 15 with gangrenous small bowel had to undergo intestinal resection. Intestinal gangrene was present with higher neutrophils count (p<0.0001) and the presence of bloody ascites (p = 0.004). Three patients died of septic shock (9.68%), and the recurrence rate was 3.23%. To complete an early and accurate diagnosis, a CT scan plus physical exam seems to be the best plan. After diagnosis, an urgent laparotomy must be performed to avoid intestinal necrosis and perforation. After surgery, more than 90% of the patients can expect to have a favorable prognosis.

  12. Four-dimensional measurement of the displacement of internal fiducial and skin markers during 320-multislice computed tomography scanning of breast cancer.

    PubMed

    Yamashita, Hideomi; Okuma, Kae; Tada, Keiichiro; Shiraishi, Kenshiro; Takahashi, Wataru; Shibata-Mobayashi, Shino; Sakumi, Akira; Saotome, Naoya; Haga, Akihiro; Onoe, Tsuyoshi; Ino, Kenji; Akahane, Masaaki; Ohtomo, Kuni; Nakagawa, Keiichi

    2012-10-01

    To study the three-dimensional movement of internal tumor bed fiducial and breast skin markers, using 320-multislice computed tomography (CT); and to analyze intrafractional errors for breast cancer patients undergoing breast irradiation. This study examined 280 markers on the skin of the breast (200 markers) and on the primary tumor bed (80 markers) of 20 patients treated by external-beam photon radiotherapy. Motion assessment was analyzed in 41 respiratory phases during 20 s of cine CT in the radiotherapy position. To assess intrafractional errors resulting from respiratory motion, four-dimensional CT scans were acquired for 20 patients. Motion in the anterior-posterior (A/P) and superior-inferior (S/I) directions showed a strong correlation (|r| > 0.7) with the respiratory curve for most markers (79% and 70%, respectively). The average marker displacements between maximum and minimum value during 20 s for the 200 breast skin metal markers were 1.1 ± 0.3 mm, 2.1 ± 0.6 mm, and 1.6 ± 0.4 mm in the left-right, A/P, and S/I directions, respectively. For the 80 tumor bed clips, displacements were 0.9 ± 0.2 mm in left-right, 1.7 ± 0.5 mm in A/P, and 1.1 ± 0.3 mm in S/I. There was no significant difference in the motion between breast quadrant regions or between the primary site and the other regions. Motion in primary breast tumors was evaluated with 320-multislice CT. Very little change was detected during individual radiation treatment fractions. Copyright © 2012 Elsevier Inc. All rights reserved.

  13. Performance of turbo high-pitch dual-source CT for coronary CT angiography: first ex vivo and patient experience.

    PubMed

    Morsbach, Fabian; Gordic, Sonja; Desbiolles, Lotus; Husarik, Daniela; Frauenfelder, Thomas; Schmidt, Bernhard; Allmendinger, Thomas; Wildermuth, Simon; Alkadhi, Hatem; Leschka, Sebastian

    2014-08-01

    To evaluate image quality, maximal heart rate allowing for diagnostic imaging, and radiation dose of turbo high-pitch dual-source coronary computed tomographic angiography (CCTA). First, a cardiac motion phantom simulating heart rates (HRs) from 60-90 bpm in 5-bpm steps was examined on a third-generation dual-source 192-slice CT (prospective ECG-triggering, pitch 3.2; rotation time, 250 ms). Subjective image quality regarding the presence of motion artefacts was interpreted by two readers on a four-point scale (1, excellent; 4, non-diagnostic). Objective image quality was assessed by calculating distortion vectors. Thereafter, 20 consecutive patients (median, 50 years) undergoing clinically indicated CCTA were included. In the phantom study, image quality was rated diagnostic up to the HR75 bpm, with object distortion being 1 mm or less. Distortion increased above 1 mm at HR of 80-90 bpm. Patients had a mean HR of 66 bpm (47-78 bpm). Coronary segments were of diagnostic image quality for all patients with HR up to 73 bpm. Average effective radiation dose in patients was 0.6 ± 0.3 mSv. Our combined phantom and patient study indicates that CCTA with turbo high-pitch third-generation dual-source 192-slice CT can be performed at HR up to 75 bpm while maintaining diagnostic image quality, being associated with an average radiation dose of 0.6 mSv. • CCTA is feasible with the turbo high-pitch mode. • Turbo high-pitch CCTA provides diagnostic image quality up to 73 bpm. • The radiation dose of high-pitch CCTA is 0.6 mSv on average.

  14. Dissociation of decision making under ambiguity and decision making under risk in breast cancer patients receiving adjuvant chemotherapy: a neuropsychological study.

    PubMed

    Chen, Xingui; Zhu, Chunyan; Li, Jingjing; Qiu, Linlin; Zhang, Long; Yu, Fengqiong; Ye, Rong; Zhang, Jingjie; Wang, Kai

    2013-10-02

    There is evidence that women with breast cancer show a cognitive impairment after having undergone chemotherapy treatment; this cognitive impairment may result in behavioral deficits. However, the neural mechanism of this cognitive impairment remains unclear. The present study investigated the neural basis of the cognitive impairment caused by chemotherapy treatment by exploring the decision-making function of the executive subcomponents under ambiguity and risk in breast cancer survivors. Participants included breast cancer patients who had undergone chemotherapy (CT, N=63) or patients who did not undergo chemotherapy (non-CT, N=62), as well as matched healthy controls (HC, N=61). All participants were examined using the Iowa Gambling Task (IGT) to assess their decision-making under ambiguity, the Game of Dice Task (GDT) to assess their decision-making under risk and neuropsychological background tests. Our results indicated that during the IGT test, the chemotherapy-treated breast cancer patients selected from the disadvantageous decks with a higher frequency than the non-treated breast cancer patients or healthy controls, whereas all three groups performed at the same level when performing the GDT. The CT group demonstrated significantly lower scores in several cognitive tasks, including attention, memory, executive functions and cognitive processing, when compared with the other two groups. In addition, within the CT group, significant correlations were found between the IGT performance and information processing, as well as with working memory. This study demonstrated that breast cancer survivors treated with chemotherapy may have selective reductions in IGT performance but unimpaired GDT performance and that these deficits may result from dysfunctions in the limbic loop rather than in the dorsolateral prefrontal loop. © 2013 Elsevier B.V. All rights reserved.

  15. The 10 Pillars of Lung Cancer Screening: Rationale and Logistics of a Lung Cancer Screening Program.

    PubMed

    Fintelmann, Florian J; Bernheim, Adam; Digumarthy, Subba R; Lennes, Inga T; Kalra, Mannudeep K; Gilman, Matthew D; Sharma, Amita; Flores, Efren J; Muse, Victorine V; Shepard, Jo-Anne O

    2015-01-01

    On the basis of the National Lung Screening Trial data released in 2011, the U.S. Preventive Services Task Force made lung cancer screening (LCS) with low-dose computed tomography (CT) a public health recommendation in 2013. The Centers for Medicare and Medicaid Services (CMS) currently reimburse LCS for asymptomatic individuals aged 55-77 years who have a tobacco smoking history of at least 30 pack-years and who are either currently smoking or had quit less than 15 years earlier. Commercial insurers reimburse the cost of LCS for individuals aged 55-80 years with the same smoking history. Effective care for the millions of Americans who qualify for LCS requires an organized step-wise approach. The 10-pillar model reflects the elements required to support a successful LCS program: eligibility, education, examination ordering, image acquisition, image review, communication, referral network, quality improvement, reimbursement, and research frontiers. Examination ordering can be coupled with decision support to ensure that only eligible individuals undergo LCS. Communication of results revolves around the Lung Imaging Reporting and Data System (Lung-RADS) from the American College of Radiology. Lung-RADS is a structured decision-oriented reporting system designed to minimize the rate of false-positive screening examination results. With nodule size and morphology as discriminators, Lung-RADS links nodule management pathways to the variety of nodules present on LCS CT studies. Tracking of patient outcomes is facilitated by a CMS-approved national registry maintained by the American College of Radiology. Online supplemental material is available for this article. (©)RSNA, 2015.

  16. Iatrogenic radiation exposure to patients with early onset spine and chest wall deformities.

    PubMed

    Khorsand, Derek; Song, Kit M; Swanson, Jonathan; Alessio, Adam; Redding, Gregory; Waldhausen, John

    2013-08-01

    Retrospective cohort series. Characterize average iatrogenic radiation dose to a cohort of children with thoracic insufficiency syndrome (TIS) during assessment and treatment at a single center with vertically expandable prosthetic titanium rib. Children with TIS undergo extensive evaluations to characterize their deformity. No standardized radiographical evaluation exists, but all reports use extensive imaging. The source and level of radiation these patients receive is not currently known. We evaluated a retrospective consecutive cohort of 62 children who had surgical treatment of TIS at our center from 2001-2011. Typical care included obtaining serial radiographs, spine and chest computed tomographic (CT) scans, ventilation/perfusion scans, and magnetic resonance images. Epochs of treatment were divided into time of initial evaluation to the end of initial vertically expandable prosthetic titanium rib implantation with each subsequent epoch delineated by the next surgical intervention. The effective dose for each examination was estimated within millisieverts (mSv). Plain radiographs were calculated from references. Effective dose was directly estimated for CT scans since 2007 and an average of effective dose from 2007-2011 was used for scans before 2007. Effective dose from fluoroscopy was directly estimated. All doses were reported in mSv. A cohort of 62 children had a total of 447 procedures. There were a total of 290 CT scans, 4293 radiographs, 147 magnetic resonance images, and 134 ventilation/perfusion scans. The average accumulated effective dose was 59.6 mSv for children who had completed all treatment, 13.0 mSv up to initial surgery, and 3.2 mSv for each subsequent epoch of treatment. CT scans accounted for 74% of total radiation dose. Children managed for TIS using a consistent protocol received iatrogenic radiation doses that were on average 4 times the estimated average US background radiation exposure of 3 mSv/yr. CT scans comprised 74% of the total dose. 3.

  17. Individualized Margins in 3D Conformal Radiotherapy Planning for Lung Cancer: Analysis of Physiological Movements and Their Dosimetric Impacts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Germain, Francois; Beaulieu, Luc; Fortin, Andre

    2008-04-01

    In conformal radiotherapy planning for lung cancer, respiratory movements are not taken into account when a single computed tomography (CT) scan is performed. This study examines tumor movements to design individualized margins to account for these movements and evaluates their dosimetric impacts on planning volume. Fifteen patients undergoing CT-based planning for radical radiotherapy for localized lung cancer formed the study cohort. A reference plan was constructed based on reference gross, clinical, and planning target volumes (rGTV, rCTV, and rPTV, respectively). The reference plans were compared with individualized plans using individualized margins obtained by using 5 serial CT scans to generatemore » individualized target volumes (iGTV, iCTV, and iPTV). Three-dimensional conformal radiation therapy was used for plan generation using 6- and 23-MV photon beams. Ten plans for each patient were generated and dose-volume histograms (DVHs) were calculated. Comparisons of volumetric and dosimetric parameters were performed using paired Student t-tests. Relative to the rGTV, the total volume occupied by the superimposed GTVs increased progressively with each additional CT scans. With the use of all 5 scans, the average increase in GTV was 52.1%. For the plans with closest dosimetric coverage, target volume was smaller (iPTV/rPTV ratio 0.808) but lung irradiation was only slightly decreased. Reduction in the proportion of lung tissue that received 20 Gy or more outside the PTV (V20) was observed both for 6-MV plans (-0.73%) and 23-MV plans (-0.65%), with p = 0.02 and p = 0.04, respectively. In conformal RT planning for the treatment of lung cancer, the use of serial CT scans to evaluate respiratory motion and to generate individualized margins to account for these motions produced only a limited lung sparing advantage.« less

  18. Correlation between presumed sinusitis-induced pain and paranasal sinus computed tomographic findings.

    PubMed

    Mudgil, Shikha P; Wise, Scott W; Hopper, Kenneth D; Kasales, Claudia J; Mauger, David; Fornadley, John A

    2002-02-01

    The correlation between facial and/or head pain in patients clinically suspected of having sinusitis and actual localized findings on sinus computed tomographic (CT) imaging are poorly understood. To prospectively evaluate the relationship of paranasal sinus pain symptoms with CT imaging. Two hundred consecutive patients referred by otolaryngologists and internists for CT of the paranasal sinuses participated by completing a questionnaire immediately before undergoing CT. Three radiologists blinded to the patients' responses scored the degree of air/fluid level, mucosal thickening, bony reaction, and mucus retention cysts using a graded scale of severity (0 to 3 points). The osteomeatal complexes and nasolacrimal ducts were also evaluated for patency. Bivariate analysis was performed to evaluate the relationship between patients' localized symptoms and CT findings in the respective sinus. One hundred sixty-three patients (82%) reported having some form of facial pain or headache. The right temple/forehead was the most frequently reported region of maximal pain. On CT imaging the maxillary sinus was the most frequently involved sinus. Bivariate analysis failed to show any relationship between patient symptoms and findings on CT. Patients with a normal CT reported a mean 5.88 sites of facial or head pain versus 5.45 sites for patients with an abnormal CT. Patient-based responses of sinonasal pain symptoms fail to correlate with findings in the respective sinuses. CT should therefore be reserved for delineating the anatomy and degree of sinus disease before surgical intervention.

  19. Outcome after open surgery repair in endovascular-suitable patients with ruptured abdominal aortic aneurysms.

    PubMed

    Krenzien, Felix; Matia, Ivan; Wiltberger, Georg; Hau, Hans-Michael; Freitas, Bruno; Moche, Michael; Schmelzle, Moritz; Jonas, Sven; Fellmer, Peter T

    2013-11-01

    Endovascular aneurysm repair (EVAR) has been suggested in several studies to be superior to open surgery repair (OSR) for the treatment of ruptured abdominal aortic aneurysms (rAAAs), but this finding might be affected by selection bias based on aneurysm morphology and patient characteristics. We tested rAAA anatomy according to EVAR suitability in patients undergoing OSR to assess the impact on mortality. This retrospective analysis reports on 83 patients with rAAAs treated between November 2002 and July 2013. Pre-operative computed tomography (CT) scans were evaluated based on EVAR suitability and were determined by blinded independent reviewers. CT scans were lacking due to acquisition in an external institution with no availability (n = 9) or solely ultrasound evaluations (n = 8). In addition patient characteristics and outcomes were assessed. All patients who underwent OSR and who had available preoperative CT scans were included in the study (n = 66). In summary, 42 % of the patients (28/66; 95 % confidence interval [CI], 30.5 - 54.4) were considered eligible for EVAR according to pre-operative CT scans and 58 % of the patients (38/66; 95 % CI, 45.6 - 69.5) were categorized as unsuitable for endovascular repair. Patients suitable for EVAR had a significantly lower prevalence of in-hospital deaths (25 % [7/28]; 95 % CI, 9 - 41) in contrast to patients unsuitable for EVAR (53 % [20/38]; 95 % CI, 36.8 - 68.5; p = 0.02). EVAR-suitable patients had a highly significant mortality reduction undergoing OSR. Thus, the present study proposes that EVAR suitability is a positive predictor for survival after open repair of rAAA.

  20. Cervical lymph node metastases of squamous cell carcinoma of unknown origin: the diagnostic value of FDG PET/CT and clinical outcome.

    PubMed

    Dale, Einar; Moan, Jon M; Osnes, Terje A; Bogsrud, Trond V

    2017-02-01

    FDG PET/CT is perceived as a valuable diagnostic tool in addition to the standard diagnostic workup for patients with isolated neck lymph nodes of squamous cell carcinoma of unknown primary (SCCUP). For patients with SCCUP intended for primary radiotherapy, we hypothesize that the previously reported FDG PET/CT detection rates are too high. From 2008 to 2015, 30 SCCUP patients were examined with FDG PET/CT. The objective of the FDG PET/CT examination was twofold: (1) improve the radiotherapy target definition, and (2) identify the primary cancer. Before the FDG PET/CT, the patients had been through a standard workup consisting of CT of the neck and chest, examination with flexible endoscopy with patient awake, panendoscopy and examination under general anesthesia, tonsillectomy and sometimes blind sampling biopsies, and MRI (floor of the mouth). All FDG PET/CTs were performed applying a flat table, head support and fixation mask as part of the radiotherapy treatment planning. Diagnostic CT with contrast was an integrated part of the PET/CT examination. Only 1/30 patients (cancer of the vallecula) had their primary cancer detected by FDG PET/CT. In addition, a non-biopsied patient with high uptake in the ipsilateral palatine tonsil was included, giving a detection rate of ≤7 % (95 % CI 2-21 %). In this retrospective study, we found that the FDG PET/CT detection rate of the primary for SCCUP patients is lower than previously reported. It is questionable whether FDG PET/CT is necessary for these patients when improved, advanced workup is available.

  1. AMPD1 polymorphism and response to regadenoson.

    PubMed

    Saab, Rayan; Zouk, Aline N; Mastouri, Ronald; Skaar, Todd C; Philips, Santosh; Kreutz, Rolf P

    2015-11-01

     AMPD1 c.34C > T (rs17602729) polymorphism results in AMPD1 deficiency. We examined the association of AMPD1 deficiency and variability of hemodynamic response to regadenoson. Genotyping for c.34C>T was performed in 267 patients undergoing regadenoson cardiac stress testing. Carriers of c.34C >T variant exhibited higher relative changes in systolic blood pressure (SBP) compared with wild-type subjects ([%] SBP change to peak: 12 ± 25 vs 5 ± 13%; p = 0.01) ([%] SBP change to nadir: -3 ± 15 vs -7 ± 11%; p = 0.04). Change in heart rate was similar between groups, but side effects were more common in carriers of the variant (+LR = 4.2; p = 0.04). AMPD1 deficiency may be involved in the modulation of regadenoson's systemic effects.

  2. Non-rigid registration of serial dedicated breast CT, longitudinal dedicated breast CT and PET/CT images using the diffeomorphic demons method.

    PubMed

    Santos, Jonathan; Chaudhari, Abhijit J; Joshi, Anand A; Ferrero, Andrea; Yang, Kai; Boone, John M; Badawi, Ramsey D

    2014-09-01

    Dedicated breast CT and PET/CT scanners provide detailed 3D anatomical and functional imaging data sets and are currently being investigated for applications in breast cancer management such as diagnosis, monitoring response to therapy and radiation therapy planning. Our objective was to evaluate the performance of the diffeomorphic demons (DD) non-rigid image registration method to spatially align 3D serial (pre- and post-contrast) dedicated breast computed tomography (CT), and longitudinally-acquired dedicated 3D breast CT and positron emission tomography (PET)/CT images. The algorithmic parameters of the DD method were optimized for the alignment of dedicated breast CT images using training data and fixed. The performance of the method for image alignment was quantitatively evaluated using three separate data sets; (1) serial breast CT pre- and post-contrast images of 20 women, (2) breast CT images of 20 women acquired before and after repositioning the subject on the scanner, and (3) dedicated breast PET/CT images of 7 women undergoing neo-adjuvant chemotherapy acquired pre-treatment and after 1 cycle of therapy. The DD registration method outperformed no registration (p < 0.001) and conventional affine registration (p ≤ 0.002) for serial and longitudinal breast CT and PET/CT image alignment. In spite of the large size of the imaging data, the computational cost of the DD method was found to be reasonable (3-5 min). Co-registration of dedicated breast CT and PET/CT images can be performed rapidly and reliably using the DD method. This is the first study evaluating the DD registration method for the alignment of dedicated breast CT and PET/CT images. Copyright © 2014 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  3. Sexually Transmitted Infections: A Novel Screening Strategy for Improving Women’s Health in Vulnerable Populations

    PubMed Central

    Frati, Elena R.; Fasoli, Ester; Martinelli, Marianna; Colzani, Daniela; Bianchi, Silvia; Carnelli, Luciana; Amendola, Antonella; Olivani, Pierfranco; Tanzi, Elisabetta

    2017-01-01

    Background: Migrant women are one of the most vulnerable population to health problems and well-being. This study aimed at implementing a counseling and preventive strategy for sexually transmitted infections (STIs) in undocumented migrant women in Milan, Italy. Methods: Women (ages 18–65) were enrolled at the NAGA Centre (2012–2013) and asked for a urine sample in order to carry out molecular detection of Human papillomavirus (HPV), Chlamydia trachomatis (Ct), Trichomonas vaginalis (Tv), Neisseria gonorrhoeae (Ng)-DNA. Socio-demographic and sexual behavior information were collected. All HPV/Ct+ women were offered Pap tests and/or were prescribed antibiotic treatment. Results: 537/757 women participated in the study (acceptability rate: 70.9%). Most of the women were from Latin America (45.6%) and Eastern Europe (30.7%); >60% of them had stable partners, did not use contraception and had had at least one pregnancy. The prevalence rates of HPV, Ct, Tv and Ng infections were 24.2%, 7.8%, 4.8% and 0%, respectively. In all, 43.2% of the positive women agreed to undergo a gynecological examination and accepted suitable treatment. Conclusions: This study shows an overall high prevalence of STIs in undocumented migrant women in Milan. The screening strategy based on counseling and urine testing contributed to the successfully high acceptability rate. More appropriate health services that adequately address all aspects of women’s health are required. PMID:28632191

  4. Augmented reality navigation in open surgery for hilar cholangiocarcinoma resection with hemihepatectomy using video-based in situ three-dimensional anatomical modeling: A case report.

    PubMed

    Tang, Rui; Ma, Longfei; Xiang, Canhong; Wang, Xuedong; Li, Ang; Liao, Hongen; Dong, Jiahong

    2017-09-01

    Patients who undergo hilar cholangiocarcinoma (HCAC) resection with concomitant hepatectomy have a high risk of postoperative morbidity and mortality due to surgical trauma to the hepatic and biliary vasculature. A 58-year-old Chinese man with yellowing skin and sclera, abdominal distension, pruritus, and anorexia for approximately 3 weeks. Magnetic resonance cholangiopancreatography and enhanced computed tomography (CT) scanning revealed a mass over the biliary tree at the porta hepatis, which diagnosed to be s a hilar cholangiocarcinoma. Three-dimensional (3D) images of the patient's hepatic and biliary structures were reconstructed preoperatively from CT data, and the 3D images were used for preoperative planning and augmented reality (AR)-assisted intraoperative navigation during open HCAC resection with hemihepatectomy. A 3D-printed model of the patient's biliary structures was also used intraoperatively as a visual reference. No serious postoperative complications occurred, and the patient was tumor-free at the 9-month follow-up examination based on CT results. AR-assisted preoperative planning and intraoperative navigation might be beneficial in other patients with HCAC patients to reduce postoperative complications and ensure disease-free survival. In our postoperative analysis, we also found that, when the3D images were superimposed 3D-printed model using a see-through integral video graphy display device, our senses of depth perception and motion parallax were improved, compared with that which we had experienced intraoperatively using the videobased AR display system.

  5. Utility of CT Findings in the Diagnosis of Cecal Volvulus.

    PubMed

    Dane, Bari; Hindman, Nicole; Johnson, Evan; Rosenkrantz, Andrew B

    2017-10-01

    The objective of our study was to assess the utility of CT features in the diagnosis of cecal volvulus. Forty-three patients undergoing CT for cecal volvulus and with surgical or clinical follow-up were included. Two radiologists (11 years and 1 year of experience) evaluated CT examinations for the following: whirl sign, abnormal cecal position, "bird beak" sign, severe cecal distention, mesenteric engorgement, a newly described "central appendix" sign (defined as abnormal appendix position near midline), and overall impression for cecal volvulus. Univariable and multivariable assessments were performed. Patients with CT examinations in which the appendix was not visible were excluded from calculations involving the central appendix sign. Fifty-one percent (n = 22) of patients had cecal volvulus. All CT findings were significantly more common in patients with cecal volvulus (p < 0.01) other than mesenteric engorgement for reader 1 (p = 0.332). Readers 1 and 2 identified the central appendix sign in 92.9% and 92.3% of patients with volvulus versus in 37.5 and 31.1% of patients without volvulus. The whirl sign exhibited a sensitivity for cecal volvulus of 90.9% for reader 1 and 95.5% for reader 2, and a specificity of 61.9% for both readers. Abnormal cecal position exhibited a sensitivity of 90.0% for reader 1 and 100.0% for reader 2 and a specificity of 66.7% and 38.1%. The bird beak sign exhibited a sensitivity of 86.4% for reader 1 and 100.0% for reader 2 and a specificity of 85.7% and 71.4%. Severe cecal distention exhibited a sensitivity of 100.0% for both readers and a specificity of 81.0% and 61.9%. Mesenteric engorgement exhibited a sensitivity of 40.9% for reader 1 and 100.0% for reader 2 and a specificity of 76.2% and 71.4%. The central appendix sign exhibited a sensitivity of 92.9% for reader 1 and 92.3% for reader 2 and a specificity of 62.5% and 68.8%. Overall impression exhibited a sensitivity of 100.0% for both readers and a specificity of 76.2% and 57.1%. At multivariable analysis, the AUC for cecal volvulus ranged from 0.787 to 0.931, and the whirl sign was an independent predictor of volvulus for both readers (p ≤ 0.014); the central appendix sign was also an independent predictor in patients with a visualized appendix for reader 2 (p ≤ 0.001). CT exhibited high diagnostic performance and very high sensitivity for cecal volvulus. The whirl sign was a significant independent predictor of volvulus for both readers.

  6. Examination of the dental cone-beam CT equipped with flat-panel-detector (FPD)

    NASA Astrophysics Data System (ADS)

    Ito, Rieko; Fujita, Naotoshi; Kodera, Yoshie

    2011-03-01

    In dentistry, computed tomography (CT) is essential for diagnosis. Recently, cone-beam CT has come into use. We used an "Alphard 3030" cone-beam CT equipped with an FPD system. This system can obtain fluoroscopic and CT images. Moreover, the Alphard has 4 exposure modes for CT, and each mode has a different field of view (FOV) and voxel size. We examined the image quality of kinetic and CT images obtained using the cone-beam CT system. To evaluate kinetic image quality, we calculated the Wiener spectrum (WS) and modulation transfer function (MTF). We then analyzed the lag images and exposed a phantom. To evaluate CT image quality, we calculated WS and MTF at various places in the FOV and examined the influence of extension of the cone beam X-ray on voxel size. Furthermore, we compared the WS and MTF values of cone-beam CT to those of another CT system. Evaluation of the kinetic images showed that cone-beam CT is sufficient for clinical diagnosis and provides better image quality than the other system tested. However, during exposure of a CT image, the distance from the center influences image quality (especially MTF). Further, differences in voxel size affect image quality. It is therefore necessary to carefully position the region of interest and select an appropriate mode.

  7. [Clinical decision to perform cranial computed tomography in children with non-severe head injury].

    PubMed

    Franco-Koehrlen, Celine Alicia; Iglesias-Leboreiro, José; Bernárdez-Zapata, Isabel; Rendón-Macías, Mario Enrique

    The main goal of this article was to evaluate if the decision to perform cranial computed tomography (CT) in children with minor head injury is determined by the presence or absence of the physician during assessment in the emergency room. Clinical files of 92 patients from 8 months to 4 years of age were selected. Those children were evaluated at the emergency department of the Spanish Hospital of Mexico due to non-severe traumatic brain injury. Glasgow Coma Scale (GCS) score was determined in all patients. Groups of patients were compared: 1) patients having CT, 2) patients with a physician who attended the initial assessment, 3) patients whose attending physician did not arrive to assess the patient and 4) patients assessed by the emergency room staff. 38% of patients with non-severe brain injury underwent CT, 8.6% had a brain injury visible on the CT. Moderate intensity impacts were greater in patients with CT. Regarding the ECG, it was found that most children scored 15 points (p=0.03). In patients without a physician, a greater trend was demonstrated for performing CT. Patients with minor head injury but without neurological signs should undergo a detailed clinical evaluation in order to avoid unwarranted CT. Copyright © 2015. Publicado por Masson Doyma México S.A.

  8. A Compact Torus Fusion Reactor Utilizing a Continuously Generated Strings of CT's. The CT String Reactor, CTSR.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hartman, C W; Reisman, D B; McLean, H S

    2007-05-30

    A fusion reactor is described in which a moving string of mutually repelling compact toruses (alternating helicity, unidirectional Btheta) is generated by repetitive injection using a magnetized coaxial gun driven by continuous gun current with alternating poloidal field. An injected CT relaxes to a minimum magnetic energy equilibrium, moves into a compression cone, and enters a conducting cylinder where the plasma is heated to fusion-producing temperature. The CT then passes into a blanketed region where fusion energy is produced and, on emergence from the fusion region, the CT undergoes controlled expansion in an exit cone where an alternating poloidal fieldmore » opens the flux surfaces to directly recover the CT magnetic energy as current which is returned to the formation gun. The CT String Reactor (CTSTR) reactor satisfies all the necessary MHD stability requirements and is based on extrapolation of experimentally achieved formation, stability, and plasma confinement. It is supported by extensive 2D, MHD calculations. CTSTR employs minimal external fields supplied by normal conductors, and can produce high fusion power density with uniform wall loading. The geometric simplicity of CTSTR acts to minimize initial and maintenance costs, including periodic replacement of the reactor first wall.« less

  9. The role of fluorine-18-fluorodeoxyglucose positron emission tomography in evaluating the response to tyrosine-kinase inhibitors in patients with metastatic primary renal cell carcinoma.

    PubMed

    Caldarella, Carmelo; Muoio, Barbara; Isgrò, Maria Antonietta; Porfiri, Emilio; Treglia, Giorgio; Giovanella, Luca

    2014-09-01

    Positron emission tomography-computed tomography (PET-CT) using fluorodeoxyglucose (FDG) is increasingly used in the evaluation of patients with advanced renal cell carcinoma (RCC), primarily for staging purposes. The aim of this paper is to perform a systematic review about the usefulness of PET-CT using FDG in response assessment after treatment with tyrosine-kinase inhibitors (TKIs) in patients with advanced RCC. The scientific literature about the role of PET-CT using FDG in the assessment of response to treatment with TKIs in patients affected by advanced RCC was systematically reviewed. Seven studies about the role of PET-CT using FDG in the response assessment after treatment with TKIs (essentially sunitinib and sorafenib) in advanced RCC were retrieved in full-text and analysed, to determine the predictive role of this morpho-functional imaging method on patient outcome. To date, the role of PET-CT using FDG in evaluating the response to TKIs in metastatic RCC patients is still not well defined, partly due to heterogeneity of available studies; however, PET-CT reveals potential role for the selection of patients undergoing therapy with TKIs. The use of contrast-enhanced PET-CT appears to be promising for a "multi-dimensional" evaluation of treatment response in these patients.

  10. Physiological and Computed Tomographic Predictors of Outcome from Lung Volume Reduction Surgery

    PubMed Central

    Washko, George R.; Martinez, Fernando J.; Hoffman, Eric A.; Loring, Stephen H.; Estépar, Raúl San José; Diaz, Alejandro A.; Sciurba, Frank C.; Silverman, Edwin K.; Han, MeiLan K.; DeCamp, Malcolm; Reilly, John J.

    2010-01-01

    Rationale: Previous investigations have identified several potential predictors of outcomes from lung volume reduction surgery (LVRS). A concern regarding these studies has been their small sample size, which may limit generalizability. We therefore sought to examine radiographic and physiologic predictors of surgical outcomes in a large, multicenter clinical investigation, the National Emphysema Treatment Trial. Objectives: To identify objective radiographic and physiological indices of lung disease that have prognostic value in subjects with chronic obstructive pulmonary disease being evaluated for LVRS. Methods: A subset of the subjects undergoing LVRS in the National Emphysema Treatment Trial underwent preoperative high-resolution computed tomographic (CT) scanning of the chest and measures of static lung recoil at total lung capacity (SRtlc) and inspiratory resistance (Ri). The relationship between CT measures of emphysema, the ratio of upper to lower zone emphysema, CT measures of airway disease, SRtlc, Ri, the ratio of residual volume to total lung capacity (RV/TLC), and both 6-month postoperative changes in FEV1 and maximal exercise capacity were assessed. Measurements and Main Results: Physiological measures of lung elastic recoil and inspiratory resistance were not correlated with improvement in either the FEV1 (R = −0.03, P = 0.78 and R = –0.17, P = 0.16, respectively) or maximal exercise capacity (R = –0.02, P = 0.83 and R = 0.08, P = 0.53, respectively). The RV/TLC ratio and CT measures of emphysema and its upper to lower zone ratio were only weakly predictive of postoperative changes in both the FEV1 (R = 0.11, P = 0.01; R = 0.2, P < 0.0001; and R = 0.23, P < 0.0001, respectively) and maximal exercise capacity (R = 0.17, P = 0.0001; R = 0.15, P = 0.002; and R = 0.15, P = 0.002, respectively). CT assessments of airway disease were not predictive of change in FEV1 or exercise capacity in this cohort. Conclusions: The RV/TLC ratio and CT measures of emphysema and its distribution are weak but statistically significant predictors of outcome after LVRS. PMID:19965810

  11. Diagnostic accuracy of CT in assessing extra-regional lymphadenopathy in pancreatic and peri-ampullary cancer: a systematic review and meta-analysis.

    PubMed

    Tseng, Dorine S J; van Santvoort, Hjalmar C; Fegrachi, Samira; Besselink, Marc G; Zuithoff, Nicolaas P A; Borel Rinkes, Inne H; van Leeuwen, Maarten S; Molenaar, I Quintus

    2014-12-01

    Computed tomography (CT) is the most widely used method to assess resectability of pancreatic and peri-ampullary cancer. One of the contra-indications for curative resection is the presence of extra-regional lymph node metastases. This meta-analysis investigates the accuracy of CT in assessing extra-regional lymph node metastases in pancreatic and peri-ampullary cancer. We systematically reviewed the literature according to the PRISMA guidelines. Studies reporting on CT assessment of extra-regional lymph nodes in patients undergoing pancreatoduodenectomy were included. Data on baseline characteristics, CT-investigations and histopathological outcomes were extracted. Diagnostic accuracy, positive predictive value (PPV), negative predictive value (NPV), sensitivity and specificity were calculated for individual studies and pooled data. After screening, 4 cohort studies reporting on CT-findings and histopathological outcome in 157 patients with pancreatic or peri-ampullary cancer were included. Overall, diagnostic accuracy, specificity and NPV varied from 63 to 81, 80-100% and 67-90% respectively. However, PPV and sensitivity ranged from 0 to 100% and 0-38%. Pooled sensitivity, specificity, PPV and NPV were 25%, 86%, 28% and 84% respectively. CT has a low diagnostic accuracy in assessing extra-regional lymph node metastases in pancreatic and peri-ampullary cancer. Therefore, suspicion of extra-regional lymph node metastases on CT alone should not be considered a contra-indication for exploration. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. Non-perforated peptic ulcer disease: multidetector CT findings, complications, and differential diagnosis.

    PubMed

    Tonolini, Massimo; Ierardi, Anna Maria; Bracchi, Elena; Magistrelli, Paolo; Vella, Adriana; Carrafiello, Gianpaolo

    2017-10-01

    Despite availability of effective therapies, peptic ulcer disease (PUD) remains a major global disease, resulting from a combination of persistent Helicobacter pylori infection and widespread use of nonsteroidal anti-inflammatory drugs. Albeit endoscopy definitely represents the mainstay diagnostic technique, patients presenting to emergency departments with unexplained abdominal pain generally undergo multidetector CT as an initial investigation. Although superficial ulcers generally remain inconspicuous, careful multiplanar CT interpretation may allow to detect deep ulcers, secondary mural and extraluminal signs of peptic gastroduodenitis, thereby allowing timely endoscopic verification and appropriate treatment. This pictorial essay aims to provide radiologists with an increased familiarity with CT diagnosis of non-perforated PUD, with emphasis on differential diagnosis. Following an overview of current disease epidemiology and complications, it explains the appropriate CT acquisition and interpretation techniques, and reviews with several examples the cross-sectional findings of uncomplicated PUD. Afterwards, the CT features of PUD complications such as ulcer haemorrhage, gastric outlet obstruction, biliary and pancreatic fistulisation are presented. • Gastric and duodenal peptic ulcers are increasingly caused by nonsteroidal anti-inflammatory drugs • Multiplanar CT interpretation allows detecting deep ulcers and secondary signs of gastroduodenitis • CT diagnosis of uncomplicated peptic disease relies on direct and indirect signs • Currently the commonest complication, haemorrhage may be treated with transarterial embolisation • Other uncommon complications include gastric outlet obstruction and biliopancreatic fistulisation.

  13. Initial In Vivo Quantification of Tc-99m Sestamibi Uptake as a Function of Tissue Type in Healthy Breasts Using Dedicated Breast SPECT-CT

    PubMed Central

    Mann, Steve D.; Perez, Kristy L.; McCracken, Emily K. E.; Shah, Jainil P.; Wong, Terence Z.; Tornai, Martin P.

    2012-01-01

    A pilot study is underway to quantify in vivo the uptake and distribution of Tc-99m Sestamibi in subjects without previous history of breast cancer using a dedicated SPECT-CT breast imaging system. Subjects undergoing diagnostic parathyroid imaging studies were consented and imaged as part of this IRB-approved breast imaging study. For each of the seven subjects, one randomly selected breast was imaged prone-pendant using the dedicated, compact breast SPECT-CT system underneath the shielded patient support. Iteratively reconstructed and attenuation and/or scatter corrected images were coregistered; CT images were segmented into glandular and fatty tissue by three different methods; the average concentration of Sestamibi was determined from the SPECT data using the CT-based segmentation and previously established quantification techniques. Very minor differences between the segmentation methods were observed, and the results indicate an average image-based in vivo Sestamibi concentration of 0.10 ± 0.16 μCi/mL with no preferential uptake by glandular or fatty tissues. PMID:22956950

  14. Comparison of pre/post-operative CT image volumes to preoperative digitization of partial hepatectomies: a feasibility study in surgical validation

    NASA Astrophysics Data System (ADS)

    Dumpuri, Prashanth; Clements, Logan W.; Li, Rui; Waite, Jonathan M.; Stefansic, James D.; Geller, David A.; Miga, Michael I.; Dawant, Benoit M.

    2009-02-01

    Preoperative planning combined with image-guidance has shown promise towards increasing the accuracy of liver resection procedures. The purpose of this study was to validate one such preoperative planning tool for four patients undergoing hepatic resection. Preoperative computed tomography (CT) images acquired before surgery were used to identify tumor margins and to plan the surgical approach for resection of these tumors. Surgery was then performed with intraoperative digitization data acquire by an FDA approved image-guided liver surgery system (Pathfinder Therapeutics, Inc., Nashville, TN). Within 5-7 days after surgery, post-operative CT image volumes were acquired. Registration of data within a common coordinate reference was achieved and preoperative plans were compared to the postoperative volumes. Semi-quantitative comparisons are presented in this work and preliminary results indicate that significant liver regeneration/hypertrophy in the postoperative CT images may be present post-operatively. This could challenge pre/post operative CT volume change comparisons as a means to evaluate the accuracy of preoperative surgical plans.

  15. Is neoadjuvant chemoradiation with dose-escalation and consolidation chemotherapy sufficient to increase surgery-free and distant metastases-free survival in baseline cT3 rectal cancer?

    PubMed

    São Julião, Guilherme Pagin; Habr-Gama, Angelita; Vailati, Bruna Borba; Aguilar, Patricia Bailão; Sabbaga, Jorge; Araújo, Sérgio Eduardo Alonso; Mattacheo, Adrian; Alexandre, Flavia Andrea; Fernandez, Laura Melina; Gomes, Diogo Bugano; Gama-Rodrigues, Joaquim; Perez, Rodrigo Oliva

    2018-01-01

    Patients with cT3 rectal cancer are less likely to develop complete response to neoadjuvant chemoradiation (nCRT) and still face significant risk for systemic relapse. In this setting, radiation (RT) dose-escalation and consolidation chemotherapy in "extended" nCRT regimens have been suggested to improve primary tumor response and decrease the risks of systemic recurrences. For these reasons we compared surgery-free and distant-metastases free survival among cT3 patients undergoing standard or extended nCRT. Patients with distal and non-metastatic T3 rectal cancer managed by nCRT were retrospectively reviewed. Patients undergoing standard CRT (50.4 Gy and 2 cycles of 5FU-based chemotherapy) were compared to those undergoing extended CRT (54 Gy and 6 cycles of 5FU-based chemotherapy). Patients were assessed for tumor response at 8-10 weeks. Patients with complete clinical response (cCR) underwent organ-preservation strategy (Watch & Wait). Patients were referred to salvage surgery in the event of local recurrence during follow-up. Cox's logistic regression was performed to identify independent features associated with improved surgery-free survival after cCR and distant-metastases-free survival. 155 patients underwent standard and 66 patients extended CRT. Patients undergoing extended CRT were more likely to harbor larger initial tumor size (p = 0.04), baseline nodal metastases (cN+; p < 0.001) and higher tumor location (p = 0.02). Cox-regression analysis revealed that the type of nCRT regimen was not independently associated with distinct surgery-free survival after cCR or distant-metastases-free survival (p > 0.05). Dose-escalation and consolidation chemotherapy are insufficient to increase long-term surgery-free survival among cT3 rectal cancer patients and provides no advantage in distant metastases-free survival. Copyright © 2017 Elsevier Ltd, BASO ~ The Association for Cancer Surgery, and the European Society of Surgical Oncology. All rights reserved.

  16. Detection of osseous metastasis by 18F-NaF/18F-FDG PET/CT versus CT alone.

    PubMed

    Sampath, Srinath C; Sampath, Srihari C; Mosci, Camila; Lutz, Amelie M; Willmann, Juergen K; Mittra, Erik S; Gambhir, Sanjiv S; Iagaru, Andrei

    2015-03-01

    Sodium fluoride PET (18F-NaF) has recently reemerged as a valuable method for detection of osseous metastasis, with recent work highlighting the potential of coadministered 18F-NaF and 18F-FDG PET/CT in a single combined imaging examination. We further examined the potential of such combined examinations by comparing dual tracer 18F-NaF18/F-FDG PET/CT with CT alone for detection of osseous metastasis. Seventy-five participants with biopsy-proven malignancy were consecutively enrolled from a single center and underwent combined 18F-NaF/18F-FDG PET/CT and diagnostic CT scans. PET/CT as well as CT only images were reviewed in blinded fashion and compared with the results of clinical, imaging, or histological follow-up as a truth standard. Sensitivity of the combined 18F-NaF/18F-FDG PET/CT was higher than that of CT alone (97.4% vs 66.7%). CT and 18F-NaF/18F-FDG PET/CT were concordant in 73% of studies. Of 20 discordant cases, 18F-NaF/18F-FDG PET/CT was correct in 19 (95%). Three cases were interpreted concordantly but incorrectly, and all 3 were false positives. A single case of osseous metastasis was detected by CT alone, but not by 18F-NaF/18F-FDG PET/CT. Combined 18F-NaF/18F-FDG PET/CT outperforms CT alone and is highly sensitive and specific for detection of osseous metastases. The concordantly interpreted false-positive cases demonstrate the difficulty of distinguishing degenerative from malignant disease, whereas the single case of metastasis seen on CT but not PET highlights the need for careful review of CT images in multimodality studies.

  17. Accuracy of Monte Carlo simulations compared to in-vivo MDCT dosimetry.

    PubMed

    Bostani, Maryam; Mueller, Jonathon W; McMillan, Kyle; Cody, Dianna D; Cagnon, Chris H; DeMarco, John J; McNitt-Gray, Michael F

    2015-02-01

    The purpose of this study was to assess the accuracy of a Monte Carlo simulation-based method for estimating radiation dose from multidetector computed tomography (MDCT) by comparing simulated doses in ten patients to in-vivo dose measurements. MD Anderson Cancer Center Institutional Review Board approved the acquisition of in-vivo rectal dose measurements in a pilot study of ten patients undergoing virtual colonoscopy. The dose measurements were obtained by affixing TLD capsules to the inner lumen of rectal catheters. Voxelized patient models were generated from the MDCT images of the ten patients, and the dose to the TLD for all exposures was estimated using Monte Carlo based simulations. The Monte Carlo simulation results were compared to the in-vivo dose measurements to determine accuracy. The calculated mean percent difference between TLD measurements and Monte Carlo simulations was -4.9% with standard deviation of 8.7% and a range of -22.7% to 5.7%. The results of this study demonstrate very good agreement between simulated and measured doses in-vivo. Taken together with previous validation efforts, this work demonstrates that the Monte Carlo simulation methods can provide accurate estimates of radiation dose in patients undergoing CT examinations.

  18. Retrospective review of positron emission tomography with contrast-enhanced computed tomography in the posttreatment setting in human papillomavirus-associated oropharyngeal carcinoma.

    PubMed

    Chan, Jason Y K; Sanguineti, Giuseppe; Richmon, Jeremy D; Marur, Shanthi; Gourin, Christine G; Koch, Wayne; Chung, Christine H; Quon, Harry; Bishop, Justin A; Aygun, Nafi; Agrawal, Nishant

    2012-11-01

    To determine the value of positron emission tomography (PET) with contrast-enhanced computed tomography (CT) in assessing the need for neck dissection by retrospectively reviewing the pathology reports of patients with human papillomavirus (HPV)-associated oropharyngeal squamous cell carcinoma (SCC). Retrospective cohort study. Tertiary medical center. Seventy-seven patients with HPV-related SCC. Seventy-seven consecutive patients with a diagnosis of HPV-related SCC who were treated with radiotherapy as the primary treatment between August 2007 and October 2010 were retrospectively evaluated for radiologic and pathologic rate of persistence of nodal metastasis after completion of definitive radiotherapy. Pretreatment and posttreatment imaging included contrast-enhanced CT and PET. Response to treatment was measured on CT, PET at standardized uptake value (SUV) thresholds of 2 and 2.5, and PET/CT by a neuroradiologist in a blinded fashion. Then, the pathology report of the patients who underwent neck dissections was reviewed for nodal status after resection and correlated with the imaging findings. Of the 77 patients, 67 met the study criteria, with an average follow-up PET/CT scan at 90.5 days after completion of radiotherapy. Ten patients did not undergo follow-up PET/CT imaging. Twenty patients underwent neck dissections after completion of radiation therapy. Of these 20 patients, 4 had persistent tumor and 16 did not have viable tumor. Using the final pathology report to correlate with imaging responses, CT had a negative predictive value (NPV) of 85.7% (95% CI, 48.7%-97.4%), PET with SUV thresholds of 2 had an NPV of 91.7% (95% CI, 64.6%-98.5%), PET with a cutoff SUV of 2.5 had an NPV of 85.7% (95% CI, 60.1%-96.0%), PET/CT with an SUV of 2 had an NPV of 100% (95% CI, 59.8%-100.0%), and PET/CT with an SUV of 2.5 had an NPV of 85.7% (95% CI, 48.7%-97.4%). The 47 patients who did not undergo neck dissection had a median follow-up of 26 months without an isolated neck failure. Analysis of all 67 patients in the cohort revealed the following values: CT had an NPV of 95.7% (95% CI, 85.8%-98.8%), PET with an SUV of 2 had an NPV of 98.2% (95% CI, 90.4%-99.7%), PET with an SUV of 2.5 had an NPV of 95.0% (95% CI, 86.3%-98.3%), PET/CT with an SUV of 2 had an NPV of 100.0% (95% CI, 92.0%-100.0%), and PET/CT with an SUV of 2.5 had an NPV of 95.7% (95% CI, 85.8%-98.8%). Positron emission tomography combined with contrast-enhanced CT has a better NPV than either imaging modality alone in patients with HPV-associated oropharyngeal SCC. Furthermore, PET/CT with an SUV threshold of 2 used in patients with HPV-related SCC offers an imaging modality with a high NPV that may obviate the need for unnecessary neck dissections.

  19. Timely Antecedent CT or MRI Can Help Predict Hemorrhage Site of Posttreatment Head and Neck Cancer, With Digital Subtraction Angiography Used as the Reference Standard.

    PubMed

    Ku, Yi-Kang; Wong, Yon-Cheong; Fu, Chen-Ju; Tseng, Hsiao-Jung; Wang, Li-Jen; Wang, Chao-Jan; Chin, Shy-Chyi

    2016-04-01

    We investigated the timing of CT and MRI performed before digital subtraction angiography (DSA) in the prediction of hemorrhage sites in patients with head and neck cancers who present with acute oral or neck bleeding after receiving treatment. A total of 123 DSA examinations that evaluated 123 oral or neck bleeding events in 85 patients were analyzed. The last CT or MRI examinations performed within a time frame of 0-337 days before transarterial embolization were reviewed retrospectively, with three findings (pseudoaneurysm, air-containing necrotic tissue, and residual tumor) used to predict hemorrhage sites. DSA findings of pseudoaneurysm or active contrast extravasation were used as a reference standard. The sensitivity of CT and MRI for correctly predicting hemorrhage sites was used to determine the optimal timing of CT or MRI examinations performed before DSA. A total of 8.9% of the DSA examinations (11/123) had equivocal findings but were followed by another bleeding event for which DSA findings were positive. CT or MRI was statistically significantly better at predicting hemorrhage sites in patients with bleeding events associated with nonhypopharyngeal cancers (p = 0.019) than in those with bleeding events associated with hypopharyngeal cancers. The sensitivity of CT or MRI in the prediction of hemorrhage sites was statistically significantly higher for the common carotid artery and the internal carotid artery when CT or MRI was performed less than 30 days before bleeding events occurred. Prediction of hemorrhagic sites was better with the use of CT angiography than with the use of enhanced CT or MRI, although it was not statistically significant. DSA findings can temporarily be equivocal. CT or MRI examinations performed within 30 days of bleeding events can predict the site of hemorrhage. If no CT or MRI findings from the past 30 days are available, we suggest performing emergent CT angiography for the sake of obtaining better arterial detail.

  20. Evaluation of a semi-automated computer algorithm for measuring total fat and visceral fat content in lambs undergoing in vivo whole body computed tomography.

    PubMed

    Rosenblatt, Alana J; Scrivani, Peter V; Boisclair, Yves R; Reeves, Anthony P; Ramos-Nieves, Jose M; Xie, Yiting; Erb, Hollis N

    2017-10-01

    Computed tomography (CT) is a suitable tool for measuring body fat, since it is non-destructive and can be used to differentiate metabolically active visceral fat from total body fat. Whole body analysis of body fat is likely to be more accurate than single CT slice estimates of body fat. The aim of this study was to assess the agreement between semi-automated computer analysis of whole body volumetric CT data and conventional proximate (chemical) analysis of body fat in lambs. Data were collected prospectively from 12 lambs that underwent duplicate whole body CT, followed by slaughter and carcass analysis by dissection and chemical analysis. Agreement between methods for quantification of total and visceral fat was assessed by Bland-Altman plot analysis. The repeatability of CT was assessed for these measures using the mean difference of duplicated measures. When compared to chemical analysis, CT systematically underestimated total and visceral fat contents by more than 10% of the mean fat weight. Therefore, carcass analysis and semi-automated CT computer measurements were not interchangeable for quantifying body fat content without the use of a correction factor. CT acquisition was repeatable, with a mean difference of repeated measures being close to zero. Therefore, uncorrected whole body CT might have an application for assessment of relative changes in fat content, especially in growing lambs. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Imaging in the newborn: infant immobilizer obviates the need for anesthesia.

    PubMed

    Golan, Agneta; Marco, Rina; Raz, Hagit; Shany, Eilon

    2011-11-01

    Neonatal cerebral imaging is a sensitive technique for evaluating brain injury in the neonatal period. When performing computed tomography or magnetic resonance imaging, sedation is needed to prevent motion artifacts. However, general anesthesia in neonates carries significant risks and requires a complex logistic approach that often limits the use of these modalities. The development of infant immobilizers now enables imaging without general anesthesia and significantly increases clinical and research investigational opportunities. To assess the efficacy of the infant immobilizer instead of general anesthesia for infants undergoing imaging. The study group comprised all infants born over a 1 year period at Soroka University Medical Center who required imaging such as MRI, CT or bone scans. A MedVac Vacuum Splint infant immobilizer was used in all infants to prevent motion during imaging. The success rate of a single scan and the need for general anesthesia were assessed. Forty infants were examined during 1 year. The studies included 15 CT scans, 25 MRIs and 1 bone scan. The infants' gestational age at birth was 27-40 weeks and the examinations were performed at ages ranging from delivery to 6 months old. All imaging was successful and none of the infants required general anesthesia. An infant immobilizer should be used for imaging of newborns. Since this method carries a low risk and has a high success rate, general anesthesia in newborns is justified only when this non-invasive procedure fails.

  2. Organ doses for reference adult male and female undergoing computed tomography estimated by Monte Carlo simulations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Choonsik; Kim, Kwang Pyo; Long, Daniel

    2011-03-15

    Purpose: To develop a computed tomography (CT) organ dose estimation method designed to readily provide organ doses in a reference adult male and female for different scan ranges to investigate the degree to which existing commercial programs can reasonably match organ doses defined in these more anatomically realistic adult hybrid phantomsMethods: The x-ray fan beam in the SOMATOM Sensation 16 multidetector CT scanner was simulated within the Monte Carlo radiation transport code MCNPX2.6. The simulated CT scanner model was validated through comparison with experimentally measured lateral free-in-air dose profiles and computed tomography dose index (CTDI) values. The reference adult malemore » and female hybrid phantoms were coupled with the established CT scanner model following arm removal to simulate clinical head and other body region scans. A set of organ dose matrices were calculated for a series of consecutive axial scans ranging from the top of the head to the bottom of the phantoms with a beam thickness of 10 mm and the tube potentials of 80, 100, and 120 kVp. The organ doses for head, chest, and abdomen/pelvis examinations were calculated based on the organ dose matrices and compared to those obtained from two commercial programs, CT-EXPO and CTDOSIMETRY. Organ dose calculations were repeated for an adult stylized phantom by using the same simulation method used for the adult hybrid phantom. Results: Comparisons of both lateral free-in-air dose profiles and CTDI values through experimental measurement with the Monte Carlo simulations showed good agreement to within 9%. Organ doses for head, chest, and abdomen/pelvis scans reported in the commercial programs exceeded those from the Monte Carlo calculations in both the hybrid and stylized phantoms in this study, sometimes by orders of magnitude. Conclusions: The organ dose estimation method and dose matrices established in this study readily provides organ doses for a reference adult male and female for different CT scan ranges and technical parameters. Organ doses from existing commercial programs do not reasonably match organ doses calculated for the hybrid phantoms due to differences in phantom anatomy, as well as differences in organ dose scaling parameters. The organ dose matrices developed in this study will be extended to cover different technical parameters, CT scanner models, and various age groups.« less

  3. Influence of hormonal therapy in prostate cancer patients undergoing [18F]fluoromethyl choline PET/CT: a retrospective study.

    PubMed

    Palumbo, Barbara; Sivolella, Silvio; Palumbo, Isabella; Buresta, Tommaso; Radicchia, Valentina; Fravolini, Mario L; Ferretti, Francesca; Bellavita, Rita; Mearini, Luigi; Scialpi, Michele; Aristei, Cynthia; Pelliccia, Gianfranco

    2016-12-01

    Patients with suspected recurrence of prostate cancer undergoing [18F]fluoromethyl choline ([18F]FCH) PET/CT were retrospectively evaluated to investigate the influence of hormonal therapy (HT) in [18F]FCH uptake. [18F]FCH PET/CT was performed in 102 surgically treated patients with suspected recurrence (PSA increase >0.2 ng/mL) of prostate cancer, divided in two groups: under HT (N.=54) and without HT (N.=48) at the time of PET scanning. PET/CT was carried out by an integrated system (Biograph 6, CTI/Siemens, Knoxville, TN, USA) intravenously by administering 4.1 MBq/kg of [18F]FCH to each patient; images were acquired 60 minutes later. On the total number of patients, 66 were found to be true positives (TP), 9 false positives (FP), 5 false negatives (FN) and 22 true negatives (TN), sensitivity to [18F]FCH PET/CT was 93%, specificity 71%, accuracy 86%, positive predictive value (PPV) 88%, negative predictive value (NPV) 81%. In the 54 patients under HT, 38 were TP, 6 FP, 3 FN and 7 TN, sensitivity was 93%, specificity 54%, accuracy 83%, PPV 86% and NPV was 70%. In the 48 patients receiving no HT, 28 were TP, 3 FP, 2 FN and 15 TN, sensitivity was 93%, specificity 83%, accuracy 90%, PPV 90% and NPV 88%. A χ2 test showed that sensitivity, accuracy and PPV did not differ among patients with and without HT, while specificity and NPV were significantly lower (P<0.001) in HT treated patients. Sensitivity, accuracy and PPV were similar in patients with and without HT. Specificity and NPV were reduced in patients under HT, but further data are necessary to support if this reduction is casual or related to therapy and it could be confirmed in a larger series of patients.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marquez, Herman P., E-mail: hermanpaulo.marquezmasquiaran@usz.ch; Puippe, Gilbert; Mathew, Rishi Philip

    PurposeTo investigate the value of perfusion CT (P-CT) for early assessment of treatment response in patients undergoing radiofrequency ablation (RFA) of focal liver lesions.Methods and Materials20 consecutive patients (14 men; mean age 64 ± 14) undergoing P-CT within 24 h after RFA of liver metastases (n = 10) or HCC (n = 10) were retrospectively included. Two readers determined arterial liver perfusion (ALP, mL/min/100 mL), portal liver perfusion (PLP, mL/min/100 mL), and hepatic perfusion index (HPI, %) in all post-RFA lesions by placing a volume of interest in the necrotic central (CZ), the transition (TZ), and the surrounding parenchymal (PZ) zone. Patients were classified into complete responders (no residual tumor)more » and incomplete responders (residual/progressive tumor) using imaging follow-up with contrast-enhanced CT or MRI after a mean of 57 ± 30 days. Prediction of treatment response was evaluated using the area under the curve (AUC) from receiver operating characteristic analysis.ResultsMean ALP/PLP/HPI of both readers were 4.8/15.4/61.2 for the CZ, 9.9/16.8/66.3 for the TZ and 20.7/29.0/61.8 for the PZ. Interreader agreement of HPI was fair for the CZ (intraclass coefficient 0.713), good for the TZ (0.813), and excellent for the PZ (0.920). For both readers, there were significant differences in HPI of the CZ and TZ between responders and nonresponders (both, P < 0.05). HPI of the TZ showed the highest AUC (0.911) for prediction of residual tumor, suggesting a cut-off value of 76 %.ConclusionIncreased HPI of the transition zone assessed with P-CT after RFA might serve as an early quantitative biomarker for residual tumor in patients with focal liver lesions.« less

  5. Utility of Megavoltage Fan-Beam CT for Treatment Planning in a Head-And-Neck Cancer Patient with Extensive Dental Fillings Undergoing Helical Tomotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Claus; Liu Tianxiao; Jennelle, Richard L.

    The purpose of this study was to demonstrate the potential utility of megavoltage fan-beam computed tomography (MV-FBCT) for treatment planning in a patient undergoing helical tomotherapy for nasopharyngeal carcinoma in the presence of extensive dental artifact. A 28-year-old female with locally advanced nasopharyngeal carcinoma presented for radiation therapy. Due to the extensiveness of the dental artifact present in the oral cavity kV-CT scan acquired at simulation, which made treatment planning impossible on tomotherapy planning system, MV-FBCT imaging was obtained using the HI-ART tomotherapy treatment machine, with the patient in the treatment position, and this information was registered with her originalmore » kV-CT scan for the purposes of structure delineation, dose calculation, and treatment planning. To validate the feasibility of the MV-FBCT-generated treatment plan, an electron density CT phantom (model 465, Gammex Inc., Middleton, WI) was scanned using MV-FBCT to obtain CT number to density table. Additionally, both a 'cheese' phantom (which came with the tomotherapy treatment machine) with 2 inserted ion chambers and a generic phantom called Quasar phantom (Modus Medical Devices Inc., London, ON, Canada) with one inserted chamber were used to confirm dosimetric accuracy. The MV-FBCT could be used to clearly visualize anatomy in the region of the dental artifact and provide sufficient soft-tissue contrast to assist in the delineation of normal tissue structures and fat planes. With the elimination of the dental artifact, the MV-FBCT images allowed more accurate dose calculation by the tomotherapy system. It was confirmed that the phantom material density was determined correctly by the tomotherapy MV-FBCT number to density table. The ion chamber measurements agreed with the calculations from the MV-FBCT generated phantom plan within 2%. MV-FBCT may be useful in radiation treatment planning for nasopharyngeal cancer patients in the setting of extensive dental artifacts.« less

  6. Potential value of contrast-enhanced intraoperative ultrasonography during partial hepatectomy for metastases: an essential investigation before resection?

    PubMed

    Leen, Edward; Ceccotti, Piercarlo; Moug, Susan J; Glen, Paul; MacQuarrie, John; Angerson, Wilson J; Albrecht, Thomas; Hohmann, Joachim; Oldenburg, Anja; Ritz, Jorg Peter; Horgan, Paul G

    2006-02-01

    The aim of the study was to assess the clinical value of contrast-enhanced intraoperative ultrasound (CE-IOUS) as a novel tool in the hepatic staging of patients undergoing liver resection. Sixty patients scheduled to undergo liver resection for metastatic disease were studied. Preoperative staging with contrast-enhanced CT and/or MR scans was performed within 2 to 6 weeks of operation. Following exploration, intraoperative ultrasound (IOUS) was performed using an HDI-5000 scanner (Philips) and a finger-probe with pulse inversion harmonic (PIH) capability. CE-IOUS in the PIH mode was performed in a standardized protocol (low MI: 0.02-0.04) after intravenous injection of 3-4 mL of SonoVue (Bracco spa, Milan); all detected lesions on precontrast and postcontrast scans were counted and mapped. Any alteration in surgical management was documented following CE-IOUS compared with IOUS. Three patients were excluded due to disseminated disease on exploration. CE-IOUS was significantly more sensitive than CT/MR and IOUS in detecting liver metastases (96.1% versus 76.7% and 81.5%, respectively) (P<0.05); it altered surgical management in 29.8% (17 of 57) of cases, due to 1) additional metastases in 19.3% (11 of 57), 2) less metastases in 3.5% (2 of 57), 3) benign lesions wrongly diagnosed as metastasis on IOUS/CT in 5.3% (3 of 57), and 4) vascular proximity in 1.8% (1 of 57). Management was unchanged in 70.2% (40 of 57) despite additional lesions detected in 3.5% (2 of 57) and benign lesion wrongly diagnosed on IOUS and CT as metastasis in 1.8% (1 of 57). CE-IOUS altered combined IOUS/CT/MR staging in 35.1%. These preliminary results suggest CE-IOUS is an essential tool prior to liver resection for metastases.

  7. Is distal femoral torsion the same in both of a patient's legs? Morphometric CT study.

    PubMed

    Beranger, J-S; Dujardin, D; Taburet, J-F; Boisrenoult, P; Steltzlen, C; Beaufils, P; Pujol, N

    2018-04-18

    The rotational position of the femoral component is a primary driver of success in total knee arthroplasty. However, distal femoral torsion (DFT) varies greatly between individuals. Measuring DFT preoperatively by CT in combination with computer-assisted surgery can significantly improve the rotational positioning of the femoral component. However, a preoperative CT scan is costly and exposes the patient to radiation. These are doubled when the patient is undergoing bilateral arthroplasty. The aim of this study was to determine the DFT in both knees of a patient undergoing bilateral arthroplasty. We hypothesized that DFT was symmetric between a patient's two knees and was independent of frontal alignment. In this retrospective study of TKA cases performed between December 2008 and March 2015, 82 patients (mean age 73years) who underwent two-stage bilateral TKA (164 knees) were included. A preoperative CT scan of each knee was performed to measure the DFT using the surgical posterior condylar angle (PCA) described by Yoshioka. Two observers performed the measurements twice each, to allow calculation of the intraclass and interclass correlation coefficients. The mean PCA was 5.4° (±1.48) in the right knee and 5.4° (±1.45) in the left knee, with a left/right difference ranging from 0 to 2.2° (p=0.8). In the entire cohort, 84.6% of patients had a left/right difference of less than 1°. We found no significant differences in DFT in knees with large or small frontal deformity (deformity<10°, p=0.7; deformity>10°, p=0.5) or the presence of varus or valgus (p=0.9). The intraclass correlation coefficient was excellent (94%) and the interclass correlation coefficient was moderate to good (60% for left knees, 53% for right knees). Based on CT scan measurements, the DFT in both knees of an arthritic patient is comparable and this measurement is reproducible. This means that a single, unilateral preoperative CT scan is sufficient for planning purposes. IV (retrospective cohort study). Copyright © 2018. Published by Elsevier Masson SAS.

  8. Aortic valve calcification - a commonly observed but frequently ignored finding during CT scanning of the chest.

    PubMed

    Raju, Prashanth; Sallomi, David; George, Bindu; Patel, Hitesh; Patel, Nikhil; Lloyd, Guy

    2012-06-01

    To describe the frequency and severity of Aortic valve calcification (AVC) in an unselected cohort of patients undergoing chest CT scanning and to assess the frequency with which AVC was being reported in the radiology reports. Consecutive CT scan images of the chest and the radiological reports (December 2009 to May 2010) were reviewed at the district general hospital (DGH). AVC on CT scan was visually graded on a scale ranging from 0 to IV (0 = no calcification, IV = severe calcification). Total of 416 (232 male; 184 female) CT chest scans [Contrast enhanced 302 (72%), unenhanced 114 (28%)] were reviewed. Mean age was 70.55 ± 11.48 years. AVC in CT scans was identified in 95 of the 416 patients (22.83%). AVC classification was as follows: Grade I: 60 (63.15%), Grade II: 22 (23.15%), Grade III: 9 (9.47%), Grade IV: 4 (4.21%). Only one CT report mentioned AVC. Only 31 of 95 AVC had Transthoracic echocardiogram (TTE). The interval time between CT scan and TTE was variable.   Aortic valve calcification in CT chest scans is a common finding and studies have shown that it is strongly related to the presence and severity of aortic valve disease. As CT scans are considered as a valuable additional screening tool for detection of aortic stenosis, AVC should always be commented upon in the radiology reports. Furthermore, patients with at least Grade III and IV AVC should be sent for TTE. © 2012 Blackwell Publishing Ltd.

  9. Adrenal venous sampling for stratifying patients for surgery of adrenal nodules detected using dynamic contrast enhanced CT

    PubMed Central

    Kim, Jin Young; Kim, See Hyung; Lee, Hee Jung; Kim, Young Hwan; Kim, Mi Jeong; Cho, Seung Hyun

    2014-01-01

    PURPOSE We aimed to assess the value of adrenal venous sampling (AVS) for diagnosing primary aldosteronism (PA) subtypes in patients with a unilateral nodule detected on adrenal computed tomography (CT) and scheduled for adrenalectomy. MATERIALS AND METHODS This retrospective study included 80 consecutive patients with PA undergoing CT and AVS. Different lateralization indices were assessed, and a cutoff established using receiver operating characteristic curve analysis. The value of CT alone versus CT with AVS for differentiating PA subtypes was compared. The adrenalectomy outcome was assessed, and predictors of cure were determined using univariate analysis. RESULTS AVS was successful in 68 patients. A cortisol-corrected aldosterone affected-to-unaffected ratio cutoff of 2.0 and affected-to-inferior vena cava ratio cutoff of 1.4 were the best lateralization indices, with accuracies of 82.5% and 80.4%, respectively. CT and AVS diagnosed 38 patients with aldosterone-producing adenomas, five patients with unilateral adrenal hyperplasia, and 25 patients with bilateral adrenal hyperplasia. Of the 52 patients with a nodule detected on CT, subsequent AVS diagnosed bilateral adrenal hyperplasia in 14 patients (27%). Compared to the results of combining CT with AVS, the accuracy of CT alone for diagnosing aldosterone-producing adenomas was 71.1% (P < 0.001). The cure rate for hypertension after adrenalectomy was 39.2%, with improvement in 53.5% of patients. On univariate analysis, predictors of persistent hypertension were male gender and preoperative systolic blood pressure. CONCLUSION To avoid inappropriate surgery, AVS is necessary for diagnosing unilateral nodules with aldosterone hypersecretion detected by CT. PMID:24047720

  10. Hospital of Diagnosis Influences the Probability of Receiving Curative Treatment for Esophageal Cancer.

    PubMed

    van Putten, Margreet; Koëter, Marijn; van Laarhoven, Hanneke W M; Lemmens, Valery E P P; Siersema, Peter D; Hulshof, Maarten C C M; Verhoeven, Rob H A; Nieuwenhuijzen, Grard A P

    2018-02-01

    The aim of this article was to study the influence of hospital of diagnosis on the probability of receiving curative treatment and its impact on survival among patients with esophageal cancer (EC). Although EC surgery is centralized in the Netherlands, the disease is often diagnosed in hospitals that do not perform this procedure. Patients with potentially curable esophageal or gastroesophageal junction tumors diagnosed between 2005 and 2013 who were potentially curable (cT1-3,X, any N, M0,X) were selected from the Netherlands Cancer Registry. Multilevel logistic regression was performed to examine the probability to undergo curative treatment (resection with or without neoadjuvant treatment, definitive chemoradiotherapy, or local tumor excision) according to hospital of diagnosis. Effects of variation in probability of undergoing curative treatment among these hospitals on survival were investigated by Cox regression. All 13,017 patients with potentially curable EC, diagnosed in 91 hospitals, were included. The proportion of patients receiving curative treatment ranged from 37% to 83% and from 45% to 86% in the periods 2005-2009 and 2010-2013, respectively, depending on hospital of diagnosis. After adjustment for patient- and hospital-related characteristics these proportions ranged from 41% to 77% and from 50% to 82%, respectively (both P < 0.001). Multivariable survival analyses showed that patients diagnosed in hospitals with a low probability of undergoing curative treatment had a worse overall survival (hazard ratio = 1.13, 95% confidence interval 1.06-1.20; hazard ratio = 1.15, 95% confidence interval 1.07-1.24). The variation in probability of undergoing potentially curative treatment for EC between hospitals of diagnosis and its impact on survival indicates that treatment decision making in EC may be improved.

  11. Incidental findings on computed tomography scans in children with mild head trauma.

    PubMed

    Ortega, Henry W; Vander Velden, Heidi; Reid, Samuel

    2012-09-01

    Computed tomography (CT) scans are frequently used in managing traumatic brain injuries in children. To assess incidental findings in children with head trauma undergoing CT scan and to describe any associated clinical ramifications. Retrospective review of 524 children treated in 2 emergency departments for closed head injury who received a CT scan. Overall, 137 (26.2%) patients had an incidental finding on CT scan. The most common incidental finding was sinus opacification with an air fluid level (115/137, 83.9%). Thirty-five interventions were reported in children with incidental findings. Children 2 years old or younger were more likely to receive a prescription for antibiotics (relative risk [RR] = 2.66, 95% confidence interval [CI] = 1.08-6.51) and be referred to a specialist (RR = 10.26, 95% CI = 3.56-29.56) than older children. Incidental findings in minor head trauma are common. Clinicians should be prepared to address these findings if clinically indicated.

  12. Operation of the Preclinical Head Scanner for Proton CT.

    PubMed

    Sadrozinski, H F-W; Geoghegan, T; Harvey, E; Johnson, R P; Plautz, T E; Zatserklyaniy, A; Bashkirov, V; Hurley, R F; Piersimoni, P; Schulte, R W; Karbasi, P; Schubert, K E; Schultze, B; Giacometti, V

    2016-09-21

    We report on the operation and performance tests of a preclinical head scanner developed for proton computed tomography (pCT). After extensive preclinical testing, pCT is intended to be employed in support of proton therapy treatment planning and pre-treatment verification in patients undergoing particle-beam therapy. In order to assess the performance of the scanner, we have performed CT scans with 200 MeV protons from both the synchrotron of the Loma Linda University Medical Center (LLUMC) and the cyclotron of the Northwestern Medicine Chicago Proton Center (NMCPC). The very high sustained rate of data acquisition, exceeding one million protons per second, allowed a full 360° scan to be completed in less than 7 minutes. The reconstruction of various phantoms verified accurate reconstruction of the proton relative stopping power (RSP) and the spatial resolution in a variety of materials. The dose for an image with better than 1% uncertainty in the RSP is found to be close to 1 mGy.

  13. Single-Blinded Prospective Implementation of a Preoperative Imaging Checklist for Endoscopic Sinus Surgery.

    PubMed

    Error, Marc; Ashby, Shaelene; Orlandi, Richard R; Alt, Jeremiah A

    2018-01-01

    Objective To determine if the introduction of a systematic preoperative sinus computed tomography (CT) checklist improves identification of critical anatomic variations in sinus anatomy among patients undergoing endoscopic sinus surgery. Study Design Single-blinded prospective cohort study. Setting Tertiary care hospital. Subjects and Methods Otolaryngology residents were asked to identify critical surgical sinus anatomy on preoperative CT scans before and after introduction of a systematic approach to reviewing sinus CT scans. The percentage of correctly identified structures was documented and compared with a 2-sample t test. Results A total of 57 scans were reviewed: 28 preimplementation and 29 postimplementation. Implementation of the sinus CT checklist improved identification of critical sinus anatomy from 24% to 84% correct ( P < .001). All residents, junior and senior, demonstrated significant improvement in identification of sinus anatomic variants, including those not directly included in the systematic review implemented. Conclusion The implementation of a preoperative endoscopic sinus surgery radiographic checklist improves identification of critical anatomic sinus variations in a training population.

  14. Barium Sulfate

    MedlinePlus

    ... and intestine using x-rays or computed tomography (CAT scan, CT scan; a type of body scan that uses a ... be clearly seen by x-ray examination or CT scan. ... more times before an x-ray examination or CT scan.If you are using a barium sulfate enema, ...

  15. Implementation of a CT Scan Practice Guideline for Pediatric Trauma Patients Reduces Unnecessary Scans Without Impacting Outcomes.

    PubMed

    McGrew, Patrick R; Chestovich, Paul J; Fisher, Jay D; Kuhls, Deborah A; Fraser, Douglas R; Patel, Purvi P; Katona, Chad W; Saquib, Syed; Fildes, John J

    2018-05-04

    Computed Tomography (CT) scans are useful in the evaluation of trauma patients, but are costly and pose risks from ionizing radiation in children. Recent literature has demonstrated the utility of CT scan guidelines in the management of pediatric trauma. This study objective is to review our treatment of pediatric blunt trauma patients and evaluate CT utilization before and after CT-guideline implementation. Our Pediatric Level 2 Trauma Center (TC) implemented a CT scan practice guideline for pediatric trauma patients in March 2014. The guideline recommended for or against CT of the head and abdomen/pelvis utilizing published criteria from the Pediatric Emergency Care and Research Network (PECARN). There was no chest CT guideline. We reviewed all pediatric trauma patients for CT scans obtained during initial evaluation before and after guideline implementation, excluding inpatient scans. The Trauma Registry Database was queried to include all pediatric (age<15) trauma patients seen in our TC from 2010-2016, excluding penetrating mechanism and deaths in the TC. Scans were considered positive if organ injury was detected. Primary outcome was the proportion of patients undergoing CT and percent positive CTs. Secondary outcomes were hospital length of stay (LOS), readmissions, and mortality. Categorical and continuous variables were analyzed with Chi-square and Wilcoxon rank-sum tests, respectively. P<0.05 was considered significant. We identified 1934 patients: 1106 pre- and 828 post-guideline. Absolute reductions in head, chest, and abdomen/pelvis CT scans were 17.7%, 11.5%, and 18.8% respectively (p<0.001). Percent positive head CTs were equivalent, but percent positive chest and abdomen CT increased after implementation. Secondary outcomes were unchanged. Implementation of a pediatric CT guideline significantly decreases CT utilization, reducing the radiation exposure without a difference in outcome. Trauma centers treating pediatric patients should adopt similar guidelines to decrease unnecessary CT scans in children. Level IV, Therapeutic Study.

  16. Evaluation of organ doses in CT examinations with an infant anthropomorphic phantom.

    PubMed

    Fujii, K; Akahane, K; Miyazaki, O; Horiuchi, T; Shimada, A; Nagmatsu, H; Yamauchi, M; Yamauchi-Kawaura, C; Kawasaki, T

    2011-09-01

    The aim of this study is to evaluate organ doses in infant CT examinations with multi-detector row CT scanners. Radiation doses were measured with radiophotoluminescence glass dosemeters set in various organ positions within a 1-y-old child anthropomorphic phantom and organ doses were evaluated from the measurement values. Doses for tissues or organs within the scan range were 28-36 mGy in an infant head CT, 3-11 mGy in a chest CT, 5-11 mGy in an abdominal-pelvic CT and 2-14 mGy in a cardiac CT. The doses varied by the differences in the types of CT scanners and scan parameters used at each medical facility. Compared with those for children of various ages, the doses in an infant CT protocol were found to be similar to or slightly smaller than those in a paediatric CT for 5- or 6-y-old children.

  17. Cloud-Based CT Dose Monitoring using the DICOM-Structured Report: Fully Automated Analysis in Regard to National Diagnostic Reference Levels.

    PubMed

    Boos, J; Meineke, A; Rubbert, C; Heusch, P; Lanzman, R S; Aissa, J; Antoch, G; Kröpil, P

    2016-03-01

    To implement automated CT dose data monitoring using the DICOM-Structured Report (DICOM-SR) in order to monitor dose-related CT data in regard to national diagnostic reference levels (DRLs). We used a novel in-house co-developed software tool based on the DICOM-SR to automatically monitor dose-related data from CT examinations. The DICOM-SR for each CT examination performed between 09/2011 and 03/2015 was automatically anonymized and sent from the CT scanners to a cloud server. Data was automatically analyzed in accordance with body region, patient age and corresponding DRL for volumetric computed tomography dose index (CTDIvol) and dose length product (DLP). Data of 36,523 examinations (131,527 scan series) performed on three different CT scanners and one PET/CT were analyzed. The overall mean CTDIvol and DLP were 51.3% and 52.8% of the national DRLs, respectively. CTDIvol and DLP reached 43.8% and 43.1% for abdominal CT (n=10,590), 66.6% and 69.6% for cranial CT (n=16,098) and 37.8% and 44.0% for chest CT (n=10,387) of the compared national DRLs, respectively. Overall, the CTDIvol exceeded national DRLs in 1.9% of the examinations, while the DLP exceeded national DRLs in 2.9% of the examinations. Between different CT protocols of the same body region, radiation exposure varied up to 50% of the DRLs. The implemented cloud-based CT dose monitoring based on the DICOM-SR enables automated benchmarking in regard to national DRLs. Overall the local dose exposure from CT reached approximately 50% of these DRLs indicating that DRL actualization as well as protocol-specific DRLs are desirable. The cloud-based approach enables multi-center dose monitoring and offers great potential to further optimize radiation exposure in radiological departments. • The newly developed software based on the DICOM-Structured Report enables large-scale cloud-based CT dose monitoring • The implemented software solution enables automated benchmarking in regard to national DRLs • The local radiation exposure from CT reached approximately 50 % of the national DRLs • The cloud-based approach offers great potential for multi-center dose analysis. © Georg Thieme Verlag KG Stuttgart · New York.

  18. Pilot study for the establishment of biomarkers for radiation damage after computed tomography in children.

    PubMed

    Halm, Brunhild M; Franke, Adrian A; Lai, Jennifer F; Li, Xingnan; Custer, Laurie J; Pagano, Ian; Cooney, Robert V; Turner, Helen C; Brenner, David J

    2015-03-01

    Computed tomography (CT) is an imaging modality that exposes patients to ionizing radiation (IR). We review and report findings from our pilot study evaluating whether blood markers are altered in 17 children undergoing medically indicated CT scans. Blood was drawn before ('pre-CT') and 1 hour after ('post-CT' CT scans. Plasma carotenoids, tocopherols, Q10, ascorbic acid (AA) and uric acid (UA) were analyzed by RP-HPLC with diode-array and electrochemical detection. Dehydroascorbic acid (DHAA) was calculated by subtraction from total AA. Total antioxidant capacity (TAC) was measured using the ORAC assay. Cytokines were quantified using a multiplex immunoassay. γ-H2AX foci were visualized using immunofluorescence. Mean pre- and post-CT changes were compared using t-tests; P-levels < .05 indicated significance. All major plasma lipid soluble antioxidant levels were lower post- vs pre-CT (P < .05) possibly from the scavenging of free radicals formed by CT-induced IR. Average AA levels increased (134%) while DHAA levels were decreased (29%) post-CT, probably due to intracellular recycling of AA from DHAA. TAC levels in lipophilic and hydrophilic extracts were unchanged, suggesting that other antioxidants may have assisted in free radical quenching, which would corroborate their lower concentrations post-CT. Cytokine levels were unchanged and dose-dependent increases in γ-H2AX foci, a measure of double strand DNA breaks, were observed (P = .046, n = 3 children). Our results suggest that CT-derived IR can influence the antioxidant system and may elicit detrimental responses on the cellular level of young children. When possible and if appropriate non-IR based techniques such as ultrasound or magnetic resonance imaging should be used.

  19. The value of FDG PET/CT for follow-up of patients with melanoma: a retrospective analysis

    PubMed Central

    Vensby, Philip H; Schmidt, Grethe; Kjær, Andreas; Fischer, Barbara M

    2017-01-01

    The incidence of melanoma (MM) is among the fastest rising cancers in the western countries. Positron Emission Tomography with Computed Tomography (PET/CT) is a valuable non-invasive tool for the diagnosis and staging of patients with MM. However, research on the value of PET/CT in follow-up of melanoma patients is limited. This study assesses the diagnostic value of PET/CT for follow-up after melanoma surgery. This retrospective study includes patients with MM who performed at least one PET/CT scan after initial surgery and staging. PET/CT findings were compared to histology, MRI or fine needle aspiration (FNA) to estimate the diagnostic accuracy. The diagnostic performance of PET/CT performed in patients with and without a clinical suspicion of relapse was compared. 238 patients (526 scans) were included. Of the 526 scans 130 (25%) scans were PET-positive, 365 (69%) PET-negative, and 28 (5%) had equivocal findings. Sensitivity was 89% [0.82-0.94], specificity 92% [0.89-0.95], positive and negative predictive values of 78% [0.70-0.84] and 97% [0.94-0.98] respectively. When stratified for reason of referral there was no statistical significant difference in the diagnostic accuracy of PET/CT between patients referred with or without a clinical suspicion of relapse. This study demonstrates that PET/CT despite a moderate sensitivity has a high negative predictive value in the follow-up of melanoma patients. Thus, a negative PET/CT-scan essentially rules out relapse. However, the frequency of false positive findings is relatively high, especially among patients undergoing a “routine” PET/CT with no clinical suspicion of relapse, potentially causing anxiety and leading to further diagnostic procedures. PMID:29348980

  20. The value of FDG PET/CT for follow-up of patients with melanoma: a retrospective analysis.

    PubMed

    Vensby, Philip H; Schmidt, Grethe; Kjær, Andreas; Fischer, Barbara M

    2017-01-01

    The incidence of melanoma (MM) is among the fastest rising cancers in the western countries. Positron Emission Tomography with Computed Tomography (PET/CT) is a valuable non-invasive tool for the diagnosis and staging of patients with MM. However, research on the value of PET/CT in follow-up of melanoma patients is limited. This study assesses the diagnostic value of PET/CT for follow-up after melanoma surgery. This retrospective study includes patients with MM who performed at least one PET/CT scan after initial surgery and staging. PET/CT findings were compared to histology, MRI or fine needle aspiration (FNA) to estimate the diagnostic accuracy. The diagnostic performance of PET/CT performed in patients with and without a clinical suspicion of relapse was compared. 238 patients (526 scans) were included. Of the 526 scans 130 (25%) scans were PET-positive, 365 (69%) PET-negative, and 28 (5%) had equivocal findings. Sensitivity was 89% [0.82-0.94], specificity 92% [0.89-0.95], positive and negative predictive values of 78% [0.70-0.84] and 97% [0.94-0.98] respectively. When stratified for reason of referral there was no statistical significant difference in the diagnostic accuracy of PET/CT between patients referred with or without a clinical suspicion of relapse. This study demonstrates that PET/CT despite a moderate sensitivity has a high negative predictive value in the follow-up of melanoma patients. Thus, a negative PET/CT-scan essentially rules out relapse. However, the frequency of false positive findings is relatively high, especially among patients undergoing a "routine" PET/CT with no clinical suspicion of relapse, potentially causing anxiety and leading to further diagnostic procedures.

  1. Is There a Role for Oncotype Dx Testing in Invasive Lobular Carcinoma?

    PubMed

    Conlon, Niamh; Ross, Dara S; Howard, Jane; Catalano, Jeffrey P; Dickler, Maura N; Tan, Lee K

    2015-01-01

    Oncotype Dx Breast Cancer Assay is a 21-gene assay used in estrogen receptor (ER)-positive breast cancer to predict benefit from chemotherapy (CT). Tumors are placed into one of three risk categories based on their recurrence score (RS). This paper explores the impact of tumor histopathologic features and Oncotype Dx RS on the treatment plan for invasive lobular carcinoma (ILC). Invasive lobular carcinoma cases submitted for Oncotype Dx testing were identified from a clinical data base. The histopathologic and immunohistochemical features and RS subcategory of each tumor, and treatment regimen and medical oncologic assessments of each patient were reviewed. A total of 135 cases of ILC had RS testing, which represented 15% of all ILC diagnosed at the institution over the time period. 80% of ILC was of the classical subtype and all tumors were ER positive and human epidermal growth factor receptor 2 (HER-2) negative by immunohistochemistry. Sixty three percent of cases were low risk (LR), 35.5% were intermediate risk (IR) and 1.5% were high risk (HR). Both HR cases were pleomorphic ILC. Sixty eight percent of classical ILC had a LR score, while 70% of pleomorphic ILC had an IR score. Patients in the IR category were significantly more likely to undergo CT than patients in the LR category (54% versus 18%; p < 0.0001). In the LR category, those undergoing CT were significantly younger and more likely to have positive lymph nodes (p < 0.05). Qualitative analysis of medical oncologic assessments showed that RS played a role in decision-making on CT in 74% of cases overall. At our institution, Oncotype Dx RS currently plays a role in the management of a proportion of ILC and impacts on treatment decisions. © 2015 Wiley Periodicals, Inc.

  2. Evaluation of optimal parameters for using low-dose computed tomography to diagnose urolithiasis

    NASA Astrophysics Data System (ADS)

    Chen, Hui-Hsien; Yu, Cheng-Ching; Hsu, Fang-Yuh

    2017-11-01

    Urolithiasis is a common disease; patients suspected of suffering from urolithiasis will be examined by abdomen x-ray, Sono, Intraudio Videonous Urography (IVU) and Computed Tomography (CT). The detection rates for calculus in above examinations are respectively: 50-70% (x-ray), 50-60% (Sono), 70-90% (IVU) and 97% (CT). In addition, the effective doses are respectively: 0.63 mSv (x-ray), no radiation dose (Sono), 2.6 mSv (IVU) and 8-16 mSv (CT). Although CT has the highest detection rate for calculus, it also has the highest radiation dose. This research sought to lower the radiation dose by using CT scans with different dose conditions of standard dose (SD), 50% SD, 25% SD, and 15% SD to diagnose patients who suffer from urolithiasis and thus explore the feasibility of examining urolithiasis via CT with lower dose conditions. This research simulated the examination of patients with RANDO phantom, collocating PMMA slice phantom and pig's kidney. Fake calculuses made of five different materials of different sizes were put into the phantom and scanned individually. The results of the scanned images were given to two physicians who had many years of diagnostic experience to interpret the urolithiasis images. This study explored the different image qualities of CT with different dose conditions. In addition, this research used thermoluminescent dosimeters (TLD) to measure the radiation doses and compared the results with the dose values shown on the screen of the CT scanner to estimate the dose conversion factor (k). The research results showed that a low-dose CT was able to provide good image quality and thus have a lower radiation dose. Therefore, a low-dose CT is suggested the main examination method to diagnose patients with urolithiasis.

  3. An algorithm for intelligent sorting of CT-related dose parameters.

    PubMed

    Cook, Tessa S; Zimmerman, Stefan L; Steingall, Scott R; Boonn, William W; Kim, Woojin

    2012-02-01

    Imaging centers nationwide are seeking innovative means to record and monitor computed tomography (CT)-related radiation dose in light of multiple instances of patient overexposure to medical radiation. As a solution, we have developed RADIANCE, an automated pipeline for extraction, archival, and reporting of CT-related dose parameters. Estimation of whole-body effective dose from CT dose length product (DLP)--an indirect estimate of radiation dose--requires anatomy-specific conversion factors that cannot be applied to total DLP, but instead necessitate individual anatomy-based DLPs. A challenge exists because the total DLP reported on a dose sheet often includes multiple separate examinations (e.g., chest CT followed by abdominopelvic CT). Furthermore, the individual reported series DLPs may not be clearly or consistently labeled. For example, "arterial" could refer to the arterial phase of the triple liver CT or the arterial phase of a CT angiogram. To address this problem, we have designed an intelligent algorithm to parse dose sheets for multi-series CT examinations and correctly separate the total DLP into its anatomic components. The algorithm uses information from the departmental PACS to determine how many distinct CT examinations were concurrently performed. Then, it matches the number of distinct accession numbers to the series that were acquired and anatomically matches individual series DLPs to their appropriate CT examinations. This algorithm allows for more accurate dose analytics, but there remain instances where automatic sorting is not feasible. To ultimately improve radiology patient care, we must standardize series names and exam names to unequivocally sort exams by anatomy and correctly estimate whole-body effective dose.

  4. An algorithm for intelligent sorting of CT-related dose parameters

    NASA Astrophysics Data System (ADS)

    Cook, Tessa S.; Zimmerman, Stefan L.; Steingal, Scott; Boonn, William W.; Kim, Woojin

    2011-03-01

    Imaging centers nationwide are seeking innovative means to record and monitor CT-related radiation dose in light of multiple instances of patient over-exposure to medical radiation. As a solution, we have developed RADIANCE, an automated pipeline for extraction, archival and reporting of CT-related dose parameters. Estimation of whole-body effective dose from CT dose-length product (DLP)-an indirect estimate of radiation dose-requires anatomy-specific conversion factors that cannot be applied to total DLP, but instead necessitate individual anatomy-based DLPs. A challenge exists because the total DLP reported on a dose sheet often includes multiple separate examinations (e.g., chest CT followed by abdominopelvic CT). Furthermore, the individual reported series DLPs may not be clearly or consistently labeled. For example, Arterial could refer to the arterial phase of the triple liver CT or the arterial phase of a CT angiogram. To address this problem, we have designed an intelligent algorithm to parse dose sheets for multi-series CT examinations and correctly separate the total DLP into its anatomic components. The algorithm uses information from the departmental PACS to determine how many distinct CT examinations were concurrently performed. Then, it matches the number of distinct accession numbers to the series that were acquired, and anatomically matches individual series DLPs to their appropriate CT examinations. This algorithm allows for more accurate dose analytics, but there remain instances where automatic sorting is not feasible. To ultimately improve radiology patient care, we must standardize series names and exam names to unequivocally sort exams by anatomy and correctly estimate whole-body effective dose.

  5. Perfusion CT of the Brain and Liver and of Lung Tumors: Use of Monte Carlo Simulation for Patient Dose Estimation for Examinations With a Cone-Beam 320-MDCT Scanner.

    PubMed

    Cros, Maria; Geleijns, Jacob; Joemai, Raoul M S; Salvadó, Marçal

    2016-01-01

    The purpose of this study was to estimate the patient dose from perfusion CT examinations of the brain, lung tumors, and the liver on a cone-beam 320-MDCT scanner using a Monte Carlo simulation and the recommendations of the International Commission on Radiological Protection (ICRP). A Monte Carlo simulation based on the Electron Gamma Shower Version 4 package code was used to calculate organ doses and the effective dose in the reference computational phantoms for an adult man and adult woman as published by the ICRP. Three perfusion CT acquisition protocols--brain, lung tumor, and liver perfusion--were evaluated. Additionally, dose assessments were performed for the skin and for the eye lens. Conversion factors were obtained to estimate effective doses and organ doses from the volume CT dose index and dose-length product. The sex-averaged effective doses were approximately 4 mSv for perfusion CT of the brain and were between 23 and 26 mSv for the perfusion CT body protocols. The eye lens dose from the brain perfusion CT examination was approximately 153 mGy. The sex-averaged peak entrance skin dose (ESD) was 255 mGy for the brain perfusion CT studies, 157 mGy for the lung tumor perfusion CT studies, and 172 mGy for the liver perfusion CT studies. The perfusion CT protocols for imaging the brain, lung tumors, and the liver performed on a 320-MDCT scanner yielded patient doses that are safely below the threshold doses for deterministic effects. The eye lens dose, peak ESD, and effective doses can be estimated for other clinical perfusion CT examinations from the conversion factors that were derived in this study.

  6. MRI and CT contrast media extravasation: A systematic review.

    PubMed

    Heshmatzadeh Behzadi, Ashkan; Farooq, Zerwa; Newhouse, Jeffery H; Prince, Martin R

    2018-03-01

    This systematic review combines data from multiple papers on contrast media extravasation to identify factors contributing to increased extravasation risk. Data were extracted from 17 papers reporting 2191 extravasations in 1,104,872 patients (0.2%) undergoing computed tomography (CT) or magnetic resonance imaging (MRI). Extravasation rates were 0.045% for gadolinium-based contrast agents (GBCA) and nearly 6-fold higher, 0.26% for iodinated contrast agents. Factors associated with increased contrast media extravasations included: older age, female gender, using an existing intravenous (IV) instead of placing a new IV in radiology, in-patient status, use of automated power injection, high injection rates, catheter location, and failing to warm up the more viscous contrast media to body temperature. Contrast media extravasation is infrequent but nearly 6 times less frequent with GBCA for MRI compared with iodinated contrast used in CT.

  7. Dosimetric Quantities for Computed Tomography Examinations of Paediatric Patients on the Thoracic and Abdominal Regions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Flores-M, E.; Gamboa de Buen, I.; Buenfil, A. E.

    Computed Tomography (CT) is a high dose X ray imaging procedure and its use has rapidly increased in the last two decades fueled by the development of helical CT. The aim of this study is to present values of the dosimetric quantities for CT paediatric examinations of thoracic and abdominal regions. The protocols studied were those of chest, lung-mediastine, chest-abdomen, pulmonary high resolution and mediastine-abdomen, which are the more common examinations performed at ''Hospital Infantil de Mexico Federico Gomez'' in the thoracic-abdominal region. The measurements were performed on a Siemens SOMATOM Sensation 16 CT Scanner and the equipment used wasmore » a CT pencil ionization chamber, connected to an electrometer. This system was calibrated for RQT9 CT beam quality. A PMMA head phantom with diameter of 16 cm and length of 15 cm was also used. The dosimetric quantities measured were the weighted air kerma index (C{sub w}), the volumetric dose index (C{sub vol}) and the CT air kerma-length product. It was found that the pulmonary high resolution examination presented the highest values for the C{sub w}(31.1 mGy) and C{sub vol}(11.1 mGy). The examination with the lowest values of these two quantities was the chest-abdomen protocol with 10.5 mGy for C{sub w} and 5.5 mGy for C{sub vol}. However, this protocol presented the highest value for P{sub KL,CT}(282.2 mGy cm) when considering the average clinical length of the examinations.« less

  8. The effects of a transcontinental flight on markers of coagulation and fibrinolysis in healthy men after vigorous physical activity.

    PubMed

    Kupchak, Brian R; Kraemer, William J; Hooper, David R; Saenz, Cathy; Dulkis, Lexie L; Secola, Paul J; Brown, Lee E; Galpin, Andrew J; Coburn, Jared W; DuPont, William H; Caldwell, Lydia K; Volek, Jeff S; Maresh, Carl M

    2017-01-01

    Athletes and military service members are known to undergo strenuous exercise and sometimes have to take long haul flights soon afterwards; however, its combined effect on many physiological functions is relatively unknown. Therefore, we examined the combined effects of a full-body muscle-damaging workout and transcontinental flight on coagulation and fibrinolysis in healthy, resistance trained men. We also determined the efficacy of a full-body compression garment in limiting their coagulation responses. Nineteen healthy, resistance trained men flew from Connecticut (CT) to California (CA), performed a full-body muscle-damaging workout and then flew back to CT. Ten participants wore full-body compression garments (FCG) for the duration of both flights and during all other portions of the study except during workouts and blood draws, when they wore loose clothing. Nine controls wore loose clothing (CON) throughout the study. Blood samples were collected at 16 h and 3 h before the initial flight from CT, immediately after landing in CA, immediately before and immediately after the full-body workout in CA, immediately after landing in CT, and at 29 h after landing in CT. Plasma markers of coagulation included activated partial thromboplastin time (aPTT), prothrombin fragment 1+2 (PTF 1+2) and thrombin ant-thrombin (TAT). Markers of the fibrinolytic system included the tissue plasmigen activator (tPA), plasminogen activator inhibitor-1 (PAI-1) and D-Dimer. Both FCG and CON groups exhibited a faster aPTT after the full-body workout compared to all other time points.  Thrombin generation markers, TAT and PTF 1+2, increased significantly after the full-body workout and immediately after landing in CT. Additionally, tPA increased after the full-body workout, while PAI-1 increased before the flight to CA, after the full-body workout, and just after landing in CT. The D-Dimer significantly increased after the full-body workout and at 29 h post-flight in both groups. Between groups, aPTT was significantly faster and TAT elevated with the CON group at 29 h post-flight. Also, PAI-1 demonstrated higher concentrations immediately after landing in CT for the CON group. A full-body muscle-damaging workout in conjunction with a trans-continental flight activated the coagulation and fibrinolytic systems. Additionally, wearing a full-body compression garment may limit coagulation following a workout through the recovery period.

  9. Four-arm variable-resolution x-ray detector for CT target imaging

    NASA Astrophysics Data System (ADS)

    DiBianca, Frank A.; Gulabani, Daya; Jordan, Lawrence M.; Vangala, Sravanthi; Rendon, David; Laughter, Joseph S.; Melnyk, Roman; Gaber, M. W.; Keyes, Gary S.

    2005-04-01

    The basic VRX technique boosts spatial resolution of a CT scanner in the scan plane by two or more orders of magnitude by reducing the angle of incidence of the x-ray beam with respect to the detector surface. A four-arm Variable-Resolution X-ray (VRX) detector has been developed for CT scanning. The detector allows for "target imaging" in which an area of interest is scanned at higher resolution than the remainder of the subject, yielding even higher resolution for the focal area than that obtained from the basic VRX technique. The new VRX-CT detector comprises four quasi-identical arms each containing six 24-cell modules (576 cells total). The modules are made of individual custom CdWO4 scintillators optically-coupled to custom photodiode arrays. The maximum scan field is 40 cm for a magnification of 1.4. A significant advantage of the four-arm geometry is that it can transform quickly to the two-arm, or even the single-arm geometry, for comparison studies. These simpler geometries have already been shown experimentally to yield in-plane CT detector resolution exceeding 60 cy/mm (<8μ) for small fields of view. Geometrical size and resolution limits of the target VRX field are calculated. Two-arm VRX-CT data are used to simulate and establish the feasibility of VRX CT target imaging. A prototype target VRX-CT scanner has been built and is undergoing initial testing.

  10. Diagnostic and clinical benefit of combined coronary calcium and perfusion assessment in patients undergoing PET/CT myocardial perfusion stress imaging.

    PubMed

    Bybee, Kevin A; Lee, John; Markiewicz, Richard; Longmore, Ryan; McGhie, A Iain; O'Keefe, James H; Hsu, Bai-Ling; Kennedy, Kevin; Thompson, Randall C; Bateman, Timothy M

    2010-04-01

    A limitation of stress myocardial perfusion imaging (MPI) is the inability to detect non-obstructive coronary artery disease (CAD). One advantage of MPI with a hybrid CT device is the ability to obtain same-setting measurement of the coronary artery calcium score (CACS). Utilizing our single-center nuclear database, we identified 760 consecutive patients with: (1) no CAD history; (2) a normal clinically indicated Rb-82 PET/CT stress perfusion study; and (3) a same-setting CAC scan. 487 of 760 patients (64.1%) had subclinical CAD based on an abnormal CACS. Of those with CAC, the CACS was > or =100, > or =400, and > or =1000 in 47.0%, 22.4%, and 8.4% of patients, respectively. Less than half of the patients with CAC were receiving aspirin or statin medications prior to PET/CT imaging. Patients with CAC were more likely to be initiated or optimized on proven medical therapy for CAD immediately following PET/CT MPI compared to those without CAC. Subclinical CAD is common in patients without known CAD and normal myocardial perfusion assessed by hybrid PET/CT imaging. Identification of CAC influences subsequent physician prescribing patterns such that those with CAC are more likely to be treated with proven medical therapy for the treatment of CAD.

  11. Diagnostic accuracy of laparoscopy following computed tomography (CT) scanning for assessing the resectability with curative intent in pancreatic and periampullary cancer.

    PubMed

    Allen, Victoria B; Gurusamy, Kurinchi Selvan; Takwoingi, Yemisi; Kalia, Amun; Davidson, Brian R

    2016-07-06

    Surgical resection is the only potentially curative treatment for pancreatic and periampullary cancer. A considerable proportion of patients undergo unnecessary laparotomy because of underestimation of the extent of the cancer on computed tomography (CT) scanning. Laparoscopy can detect metastases not visualised on CT scanning, enabling better assessment of the spread of cancer (staging of cancer). This is an update to a previous Cochrane Review published in 2013 evaluating the role of diagnostic laparoscopy in assessing the resectability with curative intent in people with pancreatic and periampullary cancer. To determine the diagnostic accuracy of diagnostic laparoscopy performed as an add-on test to CT scanning in the assessment of curative resectability in pancreatic and periampullary cancer. We searched the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE via PubMed, EMBASE via OvidSP (from inception to 15 May 2016), and Science Citation Index Expanded (from 1980 to 15 May 2016). We included diagnostic accuracy studies of diagnostic laparoscopy in people with potentially resectable pancreatic and periampullary cancer on CT scan, where confirmation of liver or peritoneal involvement was by histopathological examination of suspicious (liver or peritoneal) lesions obtained at diagnostic laparoscopy or laparotomy. We accepted any criteria of resectability used in the studies. We included studies irrespective of language, publication status, or study design (prospective or retrospective). We excluded case-control studies. Two review authors independently performed data extraction and quality assessment using the QUADAS-2 tool. The specificity of diagnostic laparoscopy in all studies was 1 because there were no false positives since laparoscopy and the reference standard are one and the same if histological examination after diagnostic laparoscopy is positive. The sensitivities were therefore meta-analysed using a univariate random-effects logistic regression model. The probability of unresectability in people who had a negative laparoscopy (post-test probability for people with a negative test result) was calculated using the median probability of unresectability (pre-test probability) from the included studies, and the negative likelihood ratio derived from the model (specificity of 1 assumed). The difference between the pre-test and post-test probabilities gave the overall added value of diagnostic laparoscopy compared to the standard practice of CT scan staging alone. We included 16 studies with a total of 1146 participants in the meta-analysis. Only one study including 52 participants had a low risk of bias and low applicability concern in the patient selection domain. The median pre-test probability of unresectable disease after CT scanning across studies was 41.4% (that is 41 out of 100 participants who had resectable cancer after CT scan were found to have unresectable disease on laparotomy). The summary sensitivity of diagnostic laparoscopy was 64.4% (95% confidence interval (CI) 50.1% to 76.6%). Assuming a pre-test probability of 41.4%, the post-test probability of unresectable disease for participants with a negative test result was 0.20 (95% CI 0.15 to 0.27). This indicates that if a person is said to have resectable disease after diagnostic laparoscopy and CT scan, there is a 20% probability that their cancer will be unresectable compared to a 41% probability for those receiving CT alone.A subgroup analysis of people with pancreatic cancer gave a summary sensitivity of 67.9% (95% CI 41.1% to 86.5%). The post-test probability of unresectable disease after being considered resectable on both CT and diagnostic laparoscopy was 18% compared to 40.0% for those receiving CT alone. Diagnostic laparoscopy may decrease the rate of unnecessary laparotomy in people with pancreatic and periampullary cancer found to have resectable disease on CT scan. On average, using diagnostic laparoscopy with biopsy and histopathological confirmation of suspicious lesions prior to laparotomy would avoid 21 unnecessary laparotomies in 100 people in whom resection of cancer with curative intent is planned.

  12. Lung Cancer Screening May Benefit Those at Highest Risk

    Cancer.gov

    People at the highest risk for lung cancer, based on a risk model, may be more likely to benefit from screening with low-dose CT, a new analysis suggests. The study authors believe the findings may better define who should undergo lung cancer screening, as this Cancer Currents blog post explains.

  13. Virion stiffness regulates immature HIV-1 entry

    PubMed Central

    2013-01-01

    Background Human immunodeficiency virus type 1 (HIV-1) undergoes a protease-mediated maturation process that is required for its infectivity. Little is known about how the physical properties of viral particles change during maturation and how these changes affect the viral lifecycle. Using Atomic Force Microscopy (AFM), we previously discovered that HIV undergoes a “stiffness switch”, a dramatic reduction in particle stiffness during maturation that is mediated by the viral Envelope (Env) protein. Results In this study, we show that transmembrane-anchored Env cytoplasmic tail (CT) domain is sufficient to regulate the particle stiffness of immature HIV-1. Using this construct expressed in trans with viral Env lacking the CT domain, we show that increasing particle stiffness reduces viral entry activity in immature virions. A similar effect was also observed for immature HIV-1 pseudovirions containing Env from vesicular stomatitis virus. Conclusions This linkage between particle stiffness and viral entry activity illustrates a novel level of regulation for viral replication, providing the first evidence for a biological role of virion physical properties and suggesting a new inhibitory strategy. PMID:23305456

  14. Imaging in blunt cardiac injury: Computed tomographic findings in cardiac contusion and associated injuries.

    PubMed

    Hammer, Mark M; Raptis, Demetrios A; Cummings, Kristopher W; Mellnick, Vincent M; Bhalla, Sanjeev; Schuerer, Douglas J; Raptis, Constantine A

    2016-05-01

    Blunt cardiac injury (BCI) may manifest as cardiac contusion or, more rarely, as pericardial or myocardial rupture. Computed tomography (CT) is performed in the vast majority of blunt trauma patients, but the imaging features of cardiac contusion are not well described. To evaluate CT findings and associated injuries in patients with clinically diagnosed BCI. We identified 42 patients with blunt cardiac injury from our institution's electronic medical record. Clinical parameters, echocardiography results, and laboratory tests were recorded. Two blinded reviewers analyzed chest CTs performed in these patients for myocardial hypoenhancement and associated injuries. CT findings of severe thoracic trauma are commonly present in patients with severe BCI; 82% of patients with ECG, cardiac enzyme, and echocardiographic evidence of BCI had abnormalities of the heart or pericardium on CT; 73% had anterior rib fractures, and 64% had pulmonary contusions. Sternal fractures were only seen in 36% of such patients. However, myocardial hypoenhancement on CT is poorly sensitive for those patients with cardiac contusion: 0% of right ventricular contusions and 22% of left ventricular contusions seen on echocardiography were identified on CT. CT signs of severe thoracic trauma are frequently present in patients with severe BCI and should be regarded as indirect evidence of potential BCI. Direct CT findings of myocardial contusion, i.e. myocardial hypoenhancement, are poorly sensitive and should not be used as a screening tool. However, some left ventricular contusions can be seen on CT, and these patients could undergo echocardiography or cardiac MRI to evaluate for wall motion abnormalities. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. The combination of preoperative PET/CT and sentinel lymph node biopsy in the surgical management of early-stage cervical cancer.

    PubMed

    Papadia, Andrea; Gasparri, Maria Luisa; Genoud, Sophie; Bernd, Klaeser; Mueller, Michael D

    2017-11-01

    The aim of the study was to evaluate the use of PET/CT and/or SLN mapping alone or in combination in cervical cancer patients. Data on stage IA1-IIA cervical cancer patients undergoing PET/CT and SLN mapping were retrospectively collected. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of PET/CT and SLN mapping, alone or in combination, in identifying cervical cancer patients with lymph node metastases were calculated. Sixty patients met the inclusion criteria. PET/CT showed a sensitivity of 68%, a specificity of 84%, a PPV of 61% and a NPV of 88% in detecting lymph nodal metastases. SLN mapping showed a sensitivity of 93%, a specificity of 100%, a PPV of 100% and a NPV of 97%. The combination of PET/CT and SLN mapping showed a sensitivity of 100%, a specificity of 86%, a PPV of 72% and a NPV of 100%. For patients with tumors of >2 cm in diameter, the PET/CT showed a sensitivity of 68%, a specificity of 72%, a PPV of 61% and a NPV of 86%. SLN mapping showed a sensitivity of 93%, a specificity of 100%, a PPV of 100% and a NPV of 95%. The combination of PET/CT and SLN mapping showed a sensitivity of 100%, a specificity of 76%, a PPV of 72% and a NPV of 100%. PET/CT represents a "safety net" that helps the surgeon in identifying metastatic lymph nodes, especially in patients with larger tumors.

  16. Postmortem computed tomography in victims of military air mishaps: radiological-pathological correlation of CT findings.

    PubMed

    Levy, Gad; Goldstein, Liav; Blachar, Arye; Apter, Sara; Barenboim, Erez; Bar-Dayan, Yaron; Shamis, Ari; Atar, Eli

    2007-10-01

    A thorough medical inquiry is included in every aviation mishap investigation. While the gold standard of this investigation is a forensic pathology examination, numerous reports stress the important role of computed tomography in the postmortem evaluation of trauma victims. To characterize the findings identified by postmortem CT and compare its performance to conventional autopsy in victims of military aviation mishaps, we analyzed seven postmortem CT examinations. Musculoskeletal injuries accounted for 57.8% of the traumatic findings identified by postmortem CT. The most frequent findings were fractures of the rib (47%), skull (9.6%) and facial bones (8.6%). Abnormally located air accounted for 24% of findings, for which CT was superior (3.5% detected by autopsy, 100% by postmortem CT, P < 0.001). The performance of autopsy in detecting injuries was superior (autopsy detected 85.8% of all injuries, postmortem CT detected 53.9%, P < 0.001), especially in the detection of superficial lesions (100% detected by autopsy, 10.5% by postmortem CT, P < 0.001) and solid organ injuries (100% by autopsy, 18.5% by postmortem CT, P < 0.001). Performance in the detection of musculoskeletal injuries was similar (91.3% for autopsy, 90.3% for postmortem CT, P = not significant). Postmortem CT and autopsy have distinct performance profiles, and although the first cannot replace the latter it is a useful complementary examination.

  17. Retrospective Review of Positron Emission Tomography With Contrast-Enhanced Computed Tomography in the Posttreatment Setting in Human Papillomavirus–Associated Oropharyngeal Carcinoma

    PubMed Central

    Chan, Jason Y. K.; Sanguineti, Giuseppe; Richmon, Jeremy D.; Marur, Shanthi; Gourin, Christine G.; Koch, Wayne; Chung, Christine H.; Quon, Harry; Bishop, Justin A.; Aygun, Nafi; Agrawal, Nishant

    2013-01-01

    Objective To determine the value of positron emission tomography (PET) with contrast-enhanced computed tomography (CT) in assessing the need for neck dissection by retrospectively reviewing the pathology reports of patients with human papillomavirus (HPV)- associated oropharyngeal squamous cell carcinoma (SCC). Design Retrospective cohort study. Setting Tertiary medical center. Patients Seventy-seven patients with HPV-related SCC. Main Outcome Measures Seventy-seven consecutive patients with a diagnosis of HPV-related SCC who were treated with radiotherapy as the primary treatment between August 2007 and October 2010 were retrospectively evaluated for radiologic and pathologic rate of persistence of nodal metastasis after completion of definitive radiotherapy. Pretreatment and posttreatment imaging included contrast-enhanced CT and PET. Response to treatment was measured on CT, PET at standardized uptake value (SUV) thresholds of 2 and 2.5, and PET/CT by a neuroradiologist in a blinded fashion. Then, the pathology report of the patients who underwent neck dissections was reviewed for nodal status after resection and correlated with the imaging findings. Results Of the 77 patients, 67 met the study criteria, with an average follow-up PET/CT scan at 90.5 days after completion of radiotherapy. Ten patients did not undergo follow-up PET/CT imaging. Twenty patients underwent neck dissections after completion of radiation therapy. Of these 20 patients, 4 had persistent tumor and 16 did not have viable tumor. Using the final pathology report to correlate with imaging responses, CT had a negative predictive value (NPV) of 85.7% (95% CI, 48.7%-97.4%), PET with SUV thresholds of 2 had an NPV of 91.7% (95% CI, 64.6%-98.5%), PET with a cutoff SUV of 2.5 had an NPV of 85.7% (95% CI, 60.1%-96.0%), PET/CT with an SUV of 2 had an NPV of 100% (95% CI, 59.8%-100.0%), and PET/CT with an SUV of 2.5 had an NPV of 85.7% (95% CI, 48.7%-97.4%). The 47 patients who did not undergo neck dissection had a median follow-up of 26 months without an isolated neck failure. Analysis of all 67 patients in the cohort revealed the following values: CT had an NPV of 95.7% (95% CI, 85.8%-98.8%), PET with an SUV of 2 had an NPV of 98.2% (95% CI, 90.4%-99.7%), PET with an SUV of 2.5 had an NPV of 95.0% (95% CI, 86.3%-98.3%), PET/CT with an SUV of 2 had an NPV of 100.0% (95% CI, 92.0%-100.0%), and PET/CT with an SUV of 2.5 had an NPV of 95.7% (95% CI, 85.8%-98.8%). Conclusions Positron emission tomography combined with contrast-enhanced CT has a better NPV than either imaging modality alone in patients with HPV-associated oropharyngeal SCC. Furthermore, PET/CT with an SUV threshold of 2 used in patients with HPV-related SCC offers an imaging modality with a high NPV that may obviate the need for unnecessary neck dissections. PMID:23165378

  18. Augmented reality navigation in open surgery for hilar cholangiocarcinoma resection with hemihepatectomy using video-based in situ three-dimensional anatomical modeling

    PubMed Central

    Tang, Rui; Ma, Longfei; Xiang, Canhong; Wang, Xuedong; Li, Ang; Liao, Hongen; Dong, Jiahong

    2017-01-01

    Abstract Rationale: Patients who undergo hilar cholangiocarcinoma (HCAC) resection with concomitant hepatectomy have a high risk of postoperative morbidity and mortality due to surgical trauma to the hepatic and biliary vasculature. Patient concerns: A 58-year-old Chinese man with yellowing skin and sclera, abdominal distension, pruritus, and anorexia for approximately 3 weeks. Diagnoses: Magnetic resonance cholangiopancreatography and enhanced computed tomography (CT) scanning revealed a mass over the biliary tree at the porta hepatis, which diagnosed to be s a hilar cholangiocarcinoma. Intervention: Three-dimensional (3D) images of the patient's hepatic and biliary structures were reconstructed preoperatively from CT data, and the 3D images were used for preoperative planning and augmented reality (AR)-assisted intraoperative navigation during open HCAC resection with hemihepatectomy. A 3D-printed model of the patient's biliary structures was also used intraoperatively as a visual reference. Outcomes: No serious postoperative complications occurred, and the patient was tumor-free at the 9-month follow-up examination based on CT results. Lessons: AR-assisted preoperative planning and intraoperative navigation might be beneficial in other patients with HCAC patients to reduce postoperative complications and ensure disease-free survival. In our postoperative analysis, we also found that, when the3D images were superimposed 3D-printed model using a see-through integral video graphy display device, our senses of depth perception and motion parallax were improved, compared with that which we had experienced intraoperatively using the videobased AR display system. PMID:28906410

  19. Clinical spectrum of patients with erosion of the inner ear by jugular bulb abnormalities.

    PubMed

    Friedmann, David R; Le, B Thuy; Pramanik, Bidyut K; Lalwani, Anil K

    2010-02-01

    Anatomic variants of the jugular bulb (JB) are common; however, abnormalities such as large high riding JB and JB diverticulum (JBD) are uncommon. Rarely, the abnormal JB may erode into the inner ear. The goal of our study is to report a large series of patients with symptomatic JB erosion into the inner ear. Retrospective review in an academic medical center. Eleven patients with JB abnormality eroding into the inner ear were identified on computed tomography (CT) scan of the temporal bone. Age at presentation was from 5 years to 82 years with six males and five females. The large JB or JBD eroded into the vestibular aqueduct (n = 9) or the posterior semicircular canal (n = 4). The official radiology report usually identified the JB abnormality; however, erosion into these structures by the JB was not mentioned in all but one case. All patients were symptomatic with five having conductive hearing loss (CHL) and three complaining of pulsatile tinnitus. Those with pulsatile tinnitus and four of five with CHL had erosion into the vestibular aqueduct. Vestibular evoked myogenic potential (VEMP) findings in three of six patients were consistent with dehiscence of the inner ear. High riding large JB or JBD can erode into the inner ear and may be associated with CHL and/or pulsatile tinnitus. CT scan is diagnostic and should be examined specifically for these lesions. As patients with pulsatile tinnitus may initially undergo a magnetic resonance imaging scan, identification of JB abnormality should prompt CT scan or VEMP testing to evaluate for inner ear erosion.

  20. Computed tomography of radioactive objects and materials

    NASA Astrophysics Data System (ADS)

    Sawicka, B. D.; Murphy, R. V.; Tosello, G.; Reynolds, P. W.; Romaniszyn, T.

    1990-12-01

    Computed tomography (CT) has been performed on a number of radioactive objects and materials. Several unique technical problems are associated with CT of radioactive specimens. These include general safety considerations, techniques to reduce background-radiation effects on CT images and selection criteria for the CT source to permit object penetration and to reveal accurate values of material density. In the present paper, three groups of experiments will be described, for objects with low, medium and high levels of radioactivity. CT studies on radioactive specimens will be presented. They include the following: (1) examination of individual ceramic reactor-fuel (uranium dioxide) pellets, (2) examination of fuel samples from the Three Mile Island reactor, (3) examination of a CANDU (CANada Deuterium Uraniun: registered trademark) nuclear-fuel bundle which underwent a simulated loss-of-coolant accident resulting in high-temperature damage and (4) examination of a PWR nuclear-reactor fuel assembly.

  1. Anomalous vertebral artery origins: the first and second reports of two variants.

    PubMed

    Hsu, Daniel P; Alexander, Ashley D; Gilkeson, Robert C

    2010-06-01

    We present two cases of aberrant origins of vertebral arteries. Case 1 is of a patient undergoing evaluation of an infrarenal aortic aneurysm stent graft. Computed tomography (CT) angiogram revealed an aberrant right vertebral artery that subsequently joined a second right vertebral artery that had the typical origin off the right subclavian artery. This represents an unusual anatomic variation not previously reported in the literature. Case 2 is of a patient being evaluated for thoracic aorta injury. CT angiogram of the chest revealed a five-vessel aortic arch with aberrant origin of the bilateral vertebral arteries distal to the left subclavian artery.

  2. β-Blocker premedication does not increase the frequency of allergic reactions from coronary CT angiography: Results from the Advanced Cardiovascular Imaging Consortium.

    PubMed

    Aggarwal, Anshul; Smith, James L; Chinnaiyan, Kavitha M; Mehta, Neesurg; Boura, Judith; Khoury Abdulla, Rami; Lauter, Carl B; Raff, Gilbert L

    2015-01-01

    β-Blockers are often used for heart rate control during coronary CT angiography (CTA). Increased frequency and severity of allergic reactions to radiocontrast media (RCM) have been reported with concomitant use of β-blockers. The objectives of this study were to determine whether there is a higher incidence of allergic reactions to low-osmolar nonionic RCM in patients undergoing coronary CTA with concomitant β-blockers and to define the overall incidence and severity of allergic reactions in patients undergoing coronary CTA with and without a history of allergy to RCM. Patients undergoing coronary CTA at 47 institutions participating in the Advanced Cardiovascular Imaging Consortium registry were analyzed. The incidence and severity of allergic reactions were compared between those patients who did and those who did not receive β-blockers, as well as in subgroups of patients with and without a history of prior allergy to RCM. The incidence of allergic reaction in patients who received β-blockers was 45 of 23,867 (0.19%) compared with those who did not receive β-blockers, which was 9 of 5232 (0.17%; P = .84; odds ratio = 1.1). Of the patients with history of allergy to RCM, 4 of 706 patients (0.6%) on β-blockers experienced allergic reactions compared to 1 of 77 patients (1.3%) without β-blockers (P = .40; odds ratio = 0.43). β-Blocker pretreatment had no effect on the frequency or severity of allergic reaction in patients undergoing coronary CTA, even in patients with a past history of allergy to RCM. Copyright © 2015 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  3. Reductive dechlorination of carbon tetrachloride using buffered alkaline ascorbic acid.

    PubMed

    Lin, Ya-Ting; Liang, Chenju

    2015-10-01

    Alkaline ascorbic acid (AA) was recently discovered as a novel in-situ chemical reduction (ISCR) reagent for remediating chlorinated solvents in the subsurface. For this ISCR process, the maintenance of an alkaline pH is essential. This study investigated the possibility of the reduction of carbon tetrachloride (CT) using alkaline AA solution buffered by phosphate and by NaOH. The results indicated that CT was reduced by AA, and chloroform (CF) was a major byproduct at a phosphate buffered pH of 12. However, CT was completely reduced by AA in 2M NaOH without CF formation. In the presence of iron/soil minerals, iron could be reduced by AA and Fe(2+) tends to precipitate on the mineral surface to accelerate CT degradation. A simultaneous transfer of hydrogenolysis and dichloroelimination would occur under phosphate buffered pH 12. This implies that a high alkaline environment is a crucial factor for maintaining the dominant pathway of two electron transfer from dianionic AA to dehydroascorbic acid, and to undergo dichloroelimination of CT. Moreover, threonic acid and oxalic acid were identified to be the major AA decomposition products in alkaline solutions. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Hybrid imaging by SPECT/CT for sentinel lymph node detection in patients with cancer of the uterine cervix.

    PubMed

    Martínez, A; Zerdoud, S; Mery, E; Bouissou, E; Ferron, G; Querleu, D

    2010-12-01

    Conventional lymphoscintigraphy provides planar images with little spatial information on location of pelvic sentinel lymph nodes (SLN). SPECT has better spatial resolution and, in combination with anatomic accuracy provided by CT improves SLN preoperative localization. The aim of the study was to report on the results of hybrid imaging of SLN in early cervical cancer patients treated at Claudius Regaud Cancer Center. Stages IA-IB1 cervical cancer patients undergoing preoperative SPECT/CT for SLN detection were analysed. Forty-one patients were included. A 100% SLN detection rate was achieved when a combined technique (radiotracer and blue dye) was used. At least one SLN was clearly visualized by SPECT/CT in 39 of 41 patients (95%) and full anatomic concordance with intraoperative anatomical location of SLN was found in 37 of the 39 patients with at least one SLN identified by SPECT/CT (95%). Location of removed SLN included the external and internal iliac area in 88% patients, the common iliac area in 10.5%, and the inframesenteric para-aortic area in 1.5%. No SLN was found in the infrarenal para-aortic region. Lymph node involvement was identified in 5 patients (12.1%). SLN correctly predicted lymph node involvement in all node-positive patients. However, SPECT/CT failed to identify 1 of the 5 metastatic SLN. SPECT/CT accurately detected preoperative SLN topography and enhanced diagnostic sensitivity of SLN imaging, improving surgical approach to patients with cervical cancer staging. Diagnostic quality of anatomic landmarks of CT images of SPECT/CT could be further improved by the use of contrast injected CT. Copyright © 2010 Elsevier Inc. All rights reserved.

  5. 68 Ga-PSMA-PET/CT staging prior to definitive radiation treatment for prostate cancer.

    PubMed

    Hruby, George; Eade, Thomas; Emmett, Louise; Ho, Bao; Hsiao, Ed; Schembri, Geoff; Guo, Linxin; Kwong, Carolyn; Hunter, Julia; Byrne, Keelan; Kneebone, Andrew

    2018-04-16

    To explore the utility of prostate specific membrane antigen (PSMA)-positron emission tomography (PET)/computed tomography (CT) in addition to conventional imaging prior to definitive external beam radiation treatment (EBRT) for prostate cancer. All men undergoing PSMA-PET/CT prior to definitive EBRT for intermediate and high-risk prostate cancer were included in our ethics approved prospective database. For each patient, clinical and pathological results, in addition to scan results including site of PSMA positive disease and number of lesions, were recorded. Results of conventional imaging (bone scan, CT and multiparametric magnetic resonance imaging [MRI]) were reviewed and included. One hundred nine men underwent staging PSMA-PET/CT between May 2015 and June 2017; all patients had national comprehensive cancer network (NCCN) intermediate or high-risk prostate cancer and 87% had Gleason score (GS) 4 + 3 or higher. There was positive uptake corresponding to the primary in 108, equivocal in one. All patients with image detected nodal or bony lesions had GS 4 + 3 or more disease. Compared to conventional imaging with bone scan, CT and multiparametric MRI, PSMA-PET/CT upstaged an additional 7 patients (6.4%) from M0 to M1, 16 from N0M0 to N1M0 (14.7%) and downstaged 3 (2.8%) from M1 to M0 disease. PSMA-PET/CT identified the primary in 99% of patients, and altered staging in 21% of men with intermediate or high-risk prostate cancer referred for definitive EBRT compared to CT, bone scan and multiparametric MRI. Following this audit, we recommend the routine use of PSMA-PET/CT prior to EBRT in this patient group. © 2018 John Wiley & Sons Australia, Ltd.

  6. 3D echocardiographic analysis of aortic annulus for transcatheter aortic valve replacement using novel aortic valve quantification software: Comparison with computed tomography.

    PubMed

    Mediratta, Anuj; Addetia, Karima; Medvedofsky, Diego; Schneider, Robert J; Kruse, Eric; Shah, Atman P; Nathan, Sandeep; Paul, Jonathan D; Blair, John E; Ota, Takeyoshi; Balkhy, Husam H; Patel, Amit R; Mor-Avi, Victor; Lang, Roberto M

    2017-05-01

    With the increasing use of transcatheter aortic valve replacement (TAVR) in patients with aortic stenosis (AS), computed tomography (CT) remains the standard for annulus sizing. However, 3D transesophageal echocardiography (TEE) has been an alternative in patients with contraindications to CT. We sought to (1) test the feasibility, accuracy, and reproducibility of prototype 3DTEE analysis software (Philips) for aortic annular measurements and (2) compare the new approach to the existing echocardiographic techniques. We prospectively studied 52 patients who underwent gated contrast CT, procedural 3DTEE, and TAVR. 3DTEE images were analyzed using novel semi-automated software designed for 3D measurements of the aortic root, which uses multiplanar reconstruction, similar to CT analysis. Aortic annulus measurements included area, perimeter, and diameter calculations from these measurements. The results were compared to CT-derived values. Additionally, 3D echocardiographic measurements (3D planimetry and mitral valve analysis software adapted for the aortic valve) were also compared to the CT reference values. 3DTEE image quality was sufficient in 90% of patients for aortic annulus measurements using the new software, which were in good agreement with CT (r-values: .89-.91) and small (<4%) inter-modality nonsignificant biases. Repeated measurements showed <10% measurements variability. The new 3D analysis was the more accurate and reproducible of the existing echocardiographic techniques. Novel semi-automated 3DTEE analysis software can accurately measure aortic annulus in patients with severe AS undergoing TAVR, in better agreement with CT than the existing methodology. Accordingly, intra-procedural TEE could potentially replace CT in patients where CT carries significant risk. © 2017, Wiley Periodicals, Inc.

  7. Late effect of subtotal thyroidectomy and radioactive iodine therapy on calcitonin secretion and bone mineral density in women treated for Graves' disease

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lowery, W.D.; Thomas, C.G. Jr.; Awbrey, B.J.

    1986-12-01

    This study was designed to evaluate the effect of subtotal thyroidectomy and/or radioactive iodine therapy on plasma immunocalcitonin (iCT) levels and bone densities in patients treated for Graves' disease. Forty-eight women whose ages ranged from 29 to 79 years (mean, 55 years) were evaluated. All were at least 10 years beyond treatment. Fourteen patients had undergone subtotal thyroidectomy, 22 had received radioactive iodine therapy, and 12 had received both. Serum calcitonin levels were measured with the patient fasting and at 30 minutes and 2 hours after the ingestion of 15 mg of calcium in orange juice. Single photon absorptiometry wasmore » used to measure bone mineral density of the middle and distal radius. The mean fasting plasma levels of iCT for patients undergoing subtotal thyroidectomy was 27 +/- 2 mumol/L; women treated with radioactive iodine, 26 +/- 2; women undergoing subtotal thyroidectomy followed by radioactive iodine, 24 +/- 2, and for normal control women, 48.5 +/- 4.7. The mean stimulated iCT level of each of the patient groups was significantly lower than that of the normal controls (p = 0.01). There were no significant differences among the groups. Although there was an increased loss of bone mineral density in postmenopausal patients, with age and race as covariates, the bone densities of the distal radius in women undergoing subtotal thyroidectomy and/or receiving radioactive iodine were not significantly lower than those of normal control subjects (p greater than 0.05). These findings are consistent with other observations that patients treated by thyroidectomy and/or radioactive iodine for Graves' disease have lower basal levels of calcitonin and decreased calcitonin response to a provocative stimulus. Whether this loss of calcitonin reserve is a significant factor in development of postmenopausal osteoporosis remains unanswered.« less

  8. Is sarcopenia a useful predictor of outcome in patients after emergency laparotomy? A study using the NELA database.

    PubMed

    Trotter, John; Johnston, Judith; Ng, Alvin; Gatt, Marcel; MacFie, John; McNaught, Clare

    2018-05-01

    Introduction Studies have reported on the use of frailty as a prognostic indicator in patients undergoing elective surgery. Similar data do not exist for patients undergoing emergency surgery. The aim of this study was to evaluate the effect of preoperative sarcopenia measured by computed tomography (CT) on outcome following emergency laparotomy. Materials and methods Data from the National Emergency Laparotomy Audit database were retrieved for patients who had undergone an emergency laparotomy over 12 months at York NHS Foundation Trust. Sarcopenia was assessed by psoas density and area on preoperative CT. Mortality rates at 30 days and 1 year were recorded. Secondary outcomes included discharge rates to non-independent living. Results A total of 259 patients were included. Overall cohort 30-day and 1-year mortality was 13.9% (36/259) and 28.2% (73/259), respectively. Sarcopenia measured by psoas density was associated with increased mortality compared with patients who did not develop sarcopenia at 30 days (29.7%, 19/64, vs. 8.7%, 17/195; P < 0.001; odds ratio, OR, 4.42; 95% confidence interval, CI 2.13-9.26) and at 1 year (57.8%, 37/64, vs. 18.5%, (36/195; P < 0.001; OR 6.05; 95%CI 3.28-11.18). An increase in mortality was seen in patients with sarcopenia measured by psoas area at 30 days (21.3%, 13/61, vs. 9.1%, 17/187; OR 2.71; 95%CI 1.23-5.96, P = 0.013) and at 1 year (42.6%, 26/61, vs. 20.9%, 39/187; OR 2.82; 95% CI 1.52-5.23, P < 0.001). Conclusions Sarcopenia assessed by measurement of psoas density and area on CT is associated with increased mortality following emergency laparotomy. The use of sarcopenia as a predictive tool merits further attention and may be useful in patients undergoing emergency surgery.

  9. An unusual initial presentation of mantle cell lymphoma arising from the lymphoid stroma of warthin tumor.

    PubMed

    Arcega, Ramir S; Feinstein, Aaron J; Bhuta, Sunita; Blackwell, Keith E; Rao, Nagesh P; Pullarkat, Sheeja T

    2015-12-03

    Warthin tumors presenting concomitantly with a lymphoma is vanishingly rare with only 15 reported cases in English literature. Herein, we report an unusual initial presentation of a mantle cell lymphoma involving the lymphoid stroma of a Warthin tumor. A seventy-seven year old otherwise healthy gentleman with a 50-pack year smoking history presents with a slowly enlarging left cheek mass. CT scan of the neck demonstrated a left parotid gland tumor measuring 3.4 cm in greatest dimension. He underwent a left superficial parotidectomy, with subsequent histopathologic examination revealing a Warthin tumor with extensive expansion of the lymphoid stroma. Flow cytometric, immunohistochemical, and cytogenetic studies of the stromal component of the tumor confirmed the presence of a mantle cell lymphoma. Clinical staging demonstrated stage IVa disease, and was considered to be at low to intermediate risk due to the slow growth of the parotid lesion. The patient is undergoing close follow up with repeat PET-CT scans at six months. To the best of our knowledge, this is the first well documented collision tumor between mantle cell lymphoma and a Warthin tumor. This case also brings to light the significance of thorough evaluation of the lymphoid component of Warthin tumor.

  10. High-resolution imaging diagnosis of human fetal membrane by three-dimensional optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Ren, Hugang; Avila, Cecilia; Kaplan, Cynthia; Pan, Yingtian

    2011-11-01

    Microscopic chorionic pseudocyst (MCP) arising in the chorion leave of the human fetal membrane (FM) is a clinical precursor for preeclampsia which may progress to fatal medical conditions (e.g., abortion) if left untreated. To examine the utility of three-dimensional (3D) optical coherence tomography (OCT) for noninvasive delineation of the morphology of human fetal membranes and early clinical detection of MCP, 60 human FM specimens were acquired from 10 different subjects undergoing term cesarean delivery for an ex vivo feasibility study. Our results showed that OCT was able to identify the four-layer architectures of human FMs consisting of high-scattering decidua vera (DV, average thickness dDV ~ 92+/-38 μm), low-scattering chorion and trophoblast (CT, dCT ~ 150+/-67 μm), high-scattering subepithelial amnion (A, dA ~ 95+/-36 μm), and low-scattering epithelium (E, dE ~ 29+/-8 μm). Importantly, 3D OCT was able to instantaneously detect MCPs (low scattering due to edema, fluid buildup, vasodilatation) and track (staging) their thicknesses dMCP ranging from 24 to 615 μm. It was also shown that high-frequency ultrasound was able to compliment OCT for detecting more advanced thicker MCPs (e.g., dMCP>615 μm) because of its increased imaging depth.

  11. Unipedal Diagnostic Lymphangiography Followed by Sequential CT Examinations in Patients With Idiopathic Chyluria: A Retrospective Study.

    PubMed

    Dong, Jian; Xin, Jianfeng; Shen, Wenbin; Chen, Xiaobai; Wen, Tingguo; Zhang, Chunyan; Wang, Rengui

    2018-04-01

    The objective of our study was to investigate the clinical value of diagnostic lymphangiography followed by sequential CT examinations in patients with idiopathic chyluria. Thirty-six patients with idiopathic chyluria underwent unipedal diagnostic lymphangiography and then underwent sequential CT examinations. The examinations were reviewed separately by two radiologists. Abnormal distribution of contrast medium, lymphourinary leakages, and retrograde flow were noted, and the range and distribution of lymphatic vessel lesions were recorded. The stage of idiopathic chyluria based on CT findings and the stage based on clinical findings were compared. Therapeutic management and follow-up were recorded. Statistical analyses were performed. Compared with CT studies performed after lymphangiography, diagnostic lymphangiography showed a unique capability to depict lymphourinary leakages in three patients. Lymphourinary fistulas and abnormal dilated lymphatic vessels were found in and around kidney in all patients. CT depicted retrograde flow of lymph fluid in 47.2% of patients. The consistency in staging chyluria based on CT findings and clinical findings was fair (κ = 0.455). Twenty-nine patients underwent conservative therapy, and seven underwent surgery. Surgical therapy was superior to conservative management (no recurrence, 85.7% of patients who underwent surgery vs 62.1% of patients who underwent conservative therapy; p = 0.025). From assessing the drainage of contrast medium on unipedal diagnostic lymphangiography and the redistribution of contrast medium on sequential CT examinations, it is possible to detect the existence of lymphourinary fistulas, the precise location of lymphatic anomalies, the distribution of collateral lymphatic vessels, and hydrodynamic pressure abnormality in the lymph circulation in patients with idiopathic chyluria. CT staging of chyluria provides additional information that can be used to guide therapeutic management.

  12. Survey of computed tomography scanners in Taiwan: Dose descriptors, dose guidance levels, and effective doses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tsai, H. Y.; Tung, C. J.; Yu, C. C.

    2007-04-15

    The IAEA and the ICRP recommended dose guidance levels for the most frequent computed tomography (CT) examinations to promote strategies for the optimization of radiation dose to CT patients. A national survey, including on-site measurements and questionnaires, was conducted in Taiwan in order to establish dose guidance levels and evaluate effective doses for CT. The beam quality and output and the phantom doses were measured for nine representative CT scanners. Questionnaire forms were completed by respondents from facilities of 146 CT scanners out of 285 total scanners. Information on patient, procedure, scanner, and technique for the head and body examinationsmore » was provided. The weighted computed tomography dose index (CTDI{sub w}), the dose length product (DLP), organ doses and effective dose were calculated using measured data, questionnaire information and Monte Carlo simulation results. A cost-effective analysis was applied to derive the dose guidance levels on CTDI{sub w} and DLP for several CT examinations. The mean effective dose{+-}standard deviation distributes from 1.6{+-}0.9 mSv for the routine head examination to 13{+-}11 mSv for the examination of liver, spleen, and pancreas. The surveyed results and the dose guidance levels were provided to the national authorities to develop quality control standards and protocols for CT examinations.« less

  13. Relationship Between Clinicopathological Characteristics and PET/CT Uptake in Esophageal Squamous Cell Carcinoma: [18F]Alfatide versus [18F]FDG.

    PubMed

    Dong, Yinjun; Wei, Yuchun; Chen, Guanxuan; Huang, Yong; Song, Pingping; Liu, Shuguang; Zheng, Jinsong; Cheng, Monica; Yuan, Shuanghu

    2018-06-04

    To assess a novel radiotracer aluminum [ 18 F]fluoride-1,4,7-triazacyclononane-triacetic acid-pegylated dimeric RGD ([ 18 F]ALF-NOTA-PRGD 2 , denoted as [ 18 F]Alfatide) for positron emission tomography (PET)/X-ray computed tomography (CT) and explore the relationships between clinicopathological characteristics and maximum standard uptake values in primary (SUV P ) and metastatic lymph nodes (SUV LN ) of patients with esophageal squamous cell carcinoma (ESCC), as verified by pathologic examination and compared with those obtained with 2-deoxy-2-[ 18 F]fluoro-D-glucose ([ 18 F]DG) PET. We prospectively enrolled patients with newly diagnosed ESCC who agreed to undergo [ 18 F]Alfatide PET/CT or [ 18 F]FDG PET/CT scans before surgery at Shandong Cancer Hospital from May 2011 to July 2017. SUVs and the pathological tumor-node-metastasis (pTNM) stages of primary tumors and metastatic lymph nodes (LNs) were measured and confirmed pathologically. Immunohistochemical (IHC) staining for integrin αvβ3 was performed on tumor samples (both primary tumors and metastatic LNs) collected from nine patients. Of 61 patients who underwent PET/CT scans, 46 then underwent curative surgery and were included in our analysis (n = 21 for [ 18 F]Alfatide PET/CT and n = 25 for [ 18 F]FDG PET/CT). No significant differences in the SUV P on [ 18 F]Alfatide PET/CT or [ 18 F]FDG PET/CT were observed among the cohorts according to gender, pathological stage, T stage, status of LNs, and differentiation (all P > 0.05). The SUV LN differed significantly between the pathological stages and status of LNs both on [ 18 F]Alfatide PET/CT (P = 0.03, 0.003) and [ 18 F]FDG PET/CT (P = 0.001. < 0.001), but not according to gender (P = 0.128, 0.129), T stage (P = 0.791, 0.727), or tumor differentiation (P = 0.049, 0.053). Significant positive correlations were observed between the SUV LN on [ 18 F]Alfatide PET/CT and [ 18 F]FDG PET/CT, and pathological stage (r = 0.52, P = 0.016; r = 0.503, P = 0.01), LN status (r = 0.73, P < 0.001; r = 0.649, P < 0.001), and differentiation (r = 0.509, P < 0.019; r = 0.459, P = 0.021) were observed. No significant differences were found between the relationships of SUV P with SUV LN , length, age, gender, pathological stage, T stage, status of LN, or differentiation, or of SUV LN with length, age, gender, or T stage both on [ 18 F]Alfatide PET/CT and [ 18 F]FDG PET/CT (all P > 0.05). The quantitated expression levels of αvβ3 in primary tumors and metastatic LNs were 1.67 ± 1.12 and 3.42 ± 2.93, respectively (P = 0.031). Our results suggest that SUV LN is influenced by pathological stage, LN status, and differentiation. SUV LN may therefore serve as a new parameter for risk stratification of with ESCC patients. Moreover, [ 18 F]Alfatide PET can provide complementary molecular information about ESCC metastasis.

  14. Evaluation of a semiautomated lung mass calculation technique for internal dosimetry applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Busse, Nathan; Erwin, William; Pan, Tinsu

    2013-12-15

    Purpose: The authors sought to evaluate a simple, semiautomated lung mass estimation method using computed tomography (CT) scans obtained using a variety of acquisition techniques and reconstruction parameters for mass correction of medical internal radiation dose-based internal radionuclide radiation absorbed dose estimates.Methods: CT scans of 27 patients with lung cancer undergoing stereotactic body radiation therapy treatment planning with PET/CT were analyzed retrospectively. For each patient, free-breathing (FB) and respiratory-gated 4DCT scans were acquired. The 4DCT scans were sorted into ten respiratory phases, representing one complete respiratory cycle. An average CT reconstruction was derived from the ten-phase reconstructions. Mid expiration breath-holdmore » CT scans were acquired in the same session for many patients. Deep inspiration breath-hold diagnostic CT scans of many of the patients were obtained from different scanning sessions at similar time points to evaluate the effect of contrast administration and maximum inspiration breath-hold. Lung mass estimates were obtained using all CT scan types, and intercomparisons made to assess lung mass variation according to scan type. Lung mass estimates using the FB CT scans from PET/CT examinations of another group of ten male and ten female patients who were 21–30 years old and did not have lung disease were calculated and compared with reference lung mass values. To evaluate the effect of varying CT acquisition and reconstruction parameters on lung mass estimation, an anthropomorphic chest phantom was scanned and reconstructed with different CT parameters. CT images of the lungs were segmented using the OsiriX MD software program with a seed point of about −850 HU and an interval of 1000. Lung volume, and mean lung, tissue, and air HUs were recorded for each scan. Lung mass was calculated by assuming each voxel was a linear combination of only air and tissue. The specific gravity of lung volume was calculated using the formula (lung HU − air HU)/(tissue HU − air HU), and mass = specific gravity × total volume × 1.04 g/cm{sup 3}.Results: The range of calculated lung masses was 0.51–1.29 kg. The average male and female lung masses during FB CT were 0.80 and 0.71 kg, respectively. The calculated lung mass varied across the respiratory cycle but changed to a lesser degree than did lung volume measurements (7.3% versus 15.4%). Lung masses calculated using deep inspiration breath-hold and average CT were significantly larger (p < 0.05) than were some masses calculated using respiratory-phase and FB CT. Increased voxel size and smooth reconstruction kernels led to high lung mass estimates owing to partial volume effects.Conclusions: Organ mass correction is an important component of patient-specific internal radionuclide dosimetry. Lung mass calculation necessitates scan-based density correction to account for volume changes owing to respiration. The range of lung masses in the authors’ patient population represents lung doses for the same absorbed energy differing from 25% below to 64% above the dose found using reference phantom organ masses. With proper management of acquisition parameters and selection of FB or midexpiration breath hold scans, lung mass estimates with about 10% population precision may be achieved.« less

  15. Dosimetric and workflow evaluation of first commercial synthetic CT software for clinical use in pelvis

    NASA Astrophysics Data System (ADS)

    Tyagi, Neelam; Fontenla, Sandra; Zhang, Jing; Cloutier, Michelle; Kadbi, Mo; Mechalakos, Jim; Zelefsky, Michael; Deasy, Joe; Hunt, Margie

    2017-04-01

    To evaluate a commercial synthetic CT (syn-CT) software for use in prostate radiotherapy. Twenty-five prostate patients underwent CT and MR simulation scans in treatment position on a 3T MR scanner. A commercially available MR protocol was used that included a T2w turbo spin-echo sequence for soft-tissue contrast and a dual echo 3D mDIXON fast field echo (FFE) sequence for generating syn-CT. A dual-echo 3D FFE B 0 map was used for patient-induced susceptibility distortion analysis and a new 3D balanced-FFE sequence was evaluated for identification of implanted gold fiducial markers and subsequent image-guidance during radiotherapy delivery. Tissues were classified as air, adipose, water, trabecular/spongy bone and compact/cortical bone and assigned bulk HU values. The accuracy of syn-CT for treatment planning was analyzed by transferring the structures and plan from planning CT to syn-CT and recalculating the dose. Accuracy of localization at the treatment machine was evaluated by comparing registration of kV radiographs to either digitally reconstructed radiographs (DRRs) generated from syn-CT or traditional DRRs generated from the planning CT. Similarly, accuracy of setup using CBCT and syn-CT was compared to that using the planning CT. Finally, a MR-only simulation workflow was established and end-to-end testing was completed on five patients undergoing MR-only simulation. Dosimetric comparison between the original CT and syn-CT plans was within 0.5% on average for all structures. The de-novo optimized plans on the syn-CT met institutional clinical objectives for target and normal structures. Patient-induced susceptibility distortion based on B 0 maps was within 1 mm and 0.5 mm in the body and prostate respectively. DRR and CBCT localization based on MR-localized fiducials showed a standard deviation of  <1 mm. End-to-end testing and MR simulation workflow was successfully validated. MRI derived synthetic CT can be successfully used for a MR-only planning and treatment for prostate radiotherapy.

  16. CT-guided brachytherapy of prostate cancer: reduction of effective dose from X-ray examination

    NASA Astrophysics Data System (ADS)

    Sanin, Dmitriy B.; Biryukov, Vitaliy A.; Rusetskiy, Sergey S.; Sviridov, Pavel V.; Volodina, Tatiana V.

    2014-03-01

    Computed tomography (CT) is one of the most effective and informative diagnostic method. Though the number of CT scans among all radiographic procedures in the USA and European countries is 11% and 4% respectively, CT makes the highest contribution to the collective effective dose from all radiographic procedures, it is 67% in the USA and 40% in European countries [1-5]. Therefore it is necessary to understand the significance of dose value from CT imaging to a patient . Though CT dose from multiple scans and potential risk is of great concern in pediatric patients, this applies to adults as well. In this connection it is very important to develop optimal approaches to dose reduction and optimization of CT examination. International Commission on Radiological Protection (ICRP) in its publications recommends radiologists to be aware that often CT image quality is higher than it is necessary for diagnostic confidence[6], and there is a potential to reduce the dose which patient gets from CT examination [7]. In recent years many procedures, such as minimally invasive surgery, biopsy, brachytherapy and different types of ablation are carried out under guidance of computed tomography [6;7], and during a procedures multiple CT scans focusing on a specific anatomic region are performed. At the Clinics of MRRC different types of treatment for patients with prostate cancer are used, incuding conformal CT-guided brachytherapy, implantation of microsources of I into the gland under guidance of spiral CT [8]. So, the purpose of the study is to choose optimal method to reduce radiation dose from CT during CT-guided prostate brachytherapy and to obtain the image of desired quality.

  17. MRI and CT contrast media extravasation

    PubMed Central

    Heshmatzadeh Behzadi, Ashkan; Farooq, Zerwa; Newhouse, Jeffery H.; Prince, Martin R.

    2018-01-01

    Abstract Background: This systematic review combines data from multiple papers on contrast media extravasation to identify factors contributing to increased extravasation risk. Methods: Data were extracted from 17 papers reporting 2191 extravasations in 1,104,872 patients (0.2%) undergoing computed tomography (CT) or magnetic resonance imaging (MRI). Results: Extravasation rates were 0.045% for gadolinium-based contrast agents (GBCA) and nearly 6-fold higher, 0.26% for iodinated contrast agents. Factors associated with increased contrast media extravasations included: older age, female gender, using an existing intravenous (IV) instead of placing a new IV in radiology, in-patient status, use of automated power injection, high injection rates, catheter location, and failing to warm up the more viscous contrast media to body temperature. Conclusion: Contrast media extravasation is infrequent but nearly 6 times less frequent with GBCA for MRI compared with iodinated contrast used in CT. PMID:29489663

  18. Increased Regional Epicardial Fat Volume Associated with Reversible Myocardial Ischemia in Patients with Suspected Coronary Artery Disease

    PubMed Central

    Khawaja, Tuba; Greer, Christine; Thadani, Samir R.; Kato, Tomoko S.; Bhatia, Ketan; Shimbo, Daichi; Konkak, Andrew; Bokhari, Sabahat; Einstein, Andrew J.; Schulze, P. Christian

    2015-01-01

    Epicardial adipose tissue is a source of pro-inflammatory cytokines and has been linked to the development of coronary artery disease. No study has systematically assessed the relationship between local epicardial fat volume (EFV) and myocardial perfusion defects. We analyzed EFV in patients undergoing SPECT myocardial perfusion imaging combined with computed tomography (CT) for attenuation correction. Low-dose CT without contrast was performed in 396 consecutive patients undergoing SPECT imaging for evaluation of coronary artery disease. Regional thickness, cross-sectional areas, and total EFV were assessed. 295 patients had normal myocardial perfusion scans and 101 had abnormal perfusion scans. Mean EFVs in normal, ischemic, and infarcted hearts were 99.8 ± 82.3 cm3, 156.4 ± 121.9 cm3, and 96.3 ± 102.1 cm3, respectively (P < 0.001). Reversible perfusion defects were associated with increased local EFV compared to normal perfusion in the distribution of the right (69.2 ± 51.5 vs 46.6 ± 32.0 cm3; P = 0.03) and left anterior descending coronary artery (87.1 ± 76.4 vs 46.7 ± 40.6 cm3; P = 0.005). Our results demonstrate increased regional epicardial fat in patients with active myocardial ischemia compared to patients with myocardial scar or normal perfusion on nuclear perfusion scans. Our results suggest a potential role for cardiac CT to improve risk stratification in patients with suspected coronary artery disease. PMID:25339129

  19. Comparison of 3D bone models of the knee joint derived from CT and 3T MR imaging.

    PubMed

    Neubert, Aleš; Wilson, Katharine J; Engstrom, Craig; Surowiec, Rachel K; Paproki, Anthony; Johnson, Nicholas; Crozier, Stuart; Fripp, Jurgen; Ho, Charles P

    2017-08-01

    To examine whether magnetic resonance (MR) imaging can offer a viable alternative to computed tomography (CT) based 3D bone modeling. CT and MR (SPACE, TrueFISP, VIBE) images were acquired from the left knee joint of a fresh-frozen cadaver. The distal femur, proximal tibia, proximal fibula and patella were manually segmented from the MR and CT examinations. The MR bone models obtained from manual segmentations of all three sequences were compared to CT models using a similarity measure based on absolute mesh differences. The average absolute distance between the CT and the various MR-based bone models were all below 1mm across all bones. The VIBE sequence provided the best agreement with the CT model, followed by the SPACE, then the TrueFISP data. The most notable difference was for the proximal tibia (VIBE 0.45mm, SPACE 0.82mm, TrueFISP 0.83mm). The study indicates that 3D MR bone models may offer a feasible alternative to traditional CT-based modeling. A single radiological examination using the MR imaging would allow simultaneous assessment of both bones and soft-tissues, providing anatomically comprehensive joint models for clinical evaluation, without the ionizing radiation of CT imaging. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Patient satisfaction with the consent discussion is not improved by showing patients their computed tomography or angiography images before they undergo vascular surgery.

    PubMed

    LeBlanc, Dominic; Power, Adam H; DeRose, Guy; Duncan, Audra; Dubois, Luc

    2018-05-18

    Patient-based decision aids and other multimedia tools have been developed to help enrich the preoperative discussion between surgeon and patient. Use of these tools, however, can be time-consuming and logistically challenging. We investigated whether simply showing patients their images from preoperative computed tomography (CT) or angiography would improve patients' satisfaction with the preoperative discussion. We also examined whether this improved the patient's understanding and trust and whether it contributed to increased preoperative anxiety. Patients undergoing either elective abdominal aortic aneurysm repair or lower limb revascularization were randomly assigned to either standard perioperative discussion or perioperative discussion and review of images (CT image or angiogram). Randomization was concealed and stratified by surgeon. Primary outcome was patient satisfaction with the preoperative discussion as measured by a validated 7-item scale (score, 0-28), with higher scores indicating improved satisfaction. Secondary outcomes included patient understanding, patient anxiety, patient trust, and length of preoperative discussion. Scores were compared using t-test. Overall, 51 patients were randomized, 25 to the intervention arm (discussion and imaging) and 26 to the control arm. Most patients were male (69%), and the average age was 70 years. Forty percent of patients underwent abdominal aortic aneurysm repair, whereas 60% underwent lower limb revascularization. Patient satisfaction with the discussion was generally high, with no added improvement when preoperative images were reviewed (mean score, 24.9 ± 3.02 vs 24.8 ± 2.93; P = .88). Similarly, there was no difference in the patient's anxiety, level of trust, or understanding when the imaging review was compared with standard discussion. There was a trend toward longer preoperative discussions in the group that underwent imaging review (8.18 vs 6.35 minutes; P = .07). Showing patients their CT or angiography images during the preoperative discussion does not improve the patient's satisfaction with the consent discussion. Similarly, there was no effect on the patient's trust, understanding, or anxiety level. Our conclusions are limited by the lack of a standardized measure of patient understanding and not measuring outcomes postoperatively, both of which should be considered in future studies. Copyright © 2018 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  1. Communication Technology: Pros and Cons of Constant Connection to Work

    ERIC Educational Resources Information Center

    Diaz, Ismael; Chiaburu, Dan S.; Zimmerman, Ryan D.; Boswell, Wendy R.

    2012-01-01

    We examined the relationship between employees' attitudes related to communication technology (CT) flexibility, communication technology (CT) use, work-to-life conflict and work satisfaction. Based on data obtained from 193 employees, CT flexibility predicted more CT use. Further, CT use was associated not only with increased work satisfaction,…

  2. Intraoperative CT in the assessment of posterior wall acetabular fracture stability.

    PubMed

    Cunningham, Brian; Jackson, Kelly; Ortega, Gil

    2014-04-01

    Posterior wall acetabular fractures that involve 10% to 40% of the posterior wall may or may not require an open reduction and internal fixation. Dynamic stress examination of the acetabular fracture under fluoroscopy has been used as an intraoperative method to assess joint stability. The aim of this study was to demonstrate the value of intraoperative ISO computed tomography (CT) examination using the Siemens ISO-C imaging system (Siemens Corp, Malvern, Pennsylvania) in the assessment of posterior wall acetabular fracture stability during stress examination under anesthesia. In 5 posterior wall acetabular fractures, standard fluoroscopic images (including anteroposterior pelvis and Judet radiographs) with dynamic stress examinations were compared with the ISO-C CT imaging system to assess posterior wall fracture stability during stress examination. After review of standard intraoperative fluoroscopic images under dynamic stress examination, all 5 cases appeared to demonstrate posterior wall stability; however, when the intraoperative images from the ISO-C CT imaging system demonstrated that 1 case showed fracture instability of the posterior wall segment during stress examination, open reduction and internal fixation was performed. The use of intraoperative ISO CT imaging has shown an initial improvement in the surgeon's ability to assess the intraoperative stability of posterior wall acetabular fractures during stress examination when compared with standard fluoroscopic images. Copyright 2014, SLACK Incorporated.

  3. Target volume and artifact evaluation of a new data-driven 4D CT.

    PubMed

    Martin, Rachael; Pan, Tinsu

    Four-dimensional computed tomography (4D CT) is often used to define the internal gross target volume (IGTV) for radiation therapy of lung cancer. Traditionally, this technique requires the use of an external motion surrogate; however, a new image, data-driven 4D CT, has become available. This study aims to describe this data-driven 4D CT and compare target contours created with it to those created using standard 4D CT. Cine CT data of 35 patients undergoing stereotactic body radiation therapy were collected and sorted into phases using standard and data-driven 4D CT. IGTV contours were drawn using a semiautomated method on maximum intensity projection images of both 4D CT methods. Errors resulting from reproducibility of the method were characterized. A comparison of phase image artifacts was made using a normalized cross-correlation method that assigned a score from +1 (data-driven "better") to -1 (standard "better"). The volume difference between the data-driven and standard IGTVs was not significant (data driven was 2.1 ± 1.0% smaller, P = .08). The Dice similarity coefficient showed good similarity between the contours (0.949 ± 0.006). The mean surface separation was 0.4 ± 0.1 mm and the Hausdorff distance was 3.1 ± 0.4 mm. An average artifact score of +0.37 indicated that the data-driven method had significantly fewer and/or less severe artifacts than the standard method (P = 1.5 × 10 -5 for difference from 0). On average, the difference between IGTVs derived from data-driven and standard 4D CT was not clinically relevant or statistically significant, suggesting data-driven 4D CT can be used in place of standard 4D CT without adjustments to IGTVs. The relatively large differences in some patients were usually attributed to limitations in automatic contouring or differences in artifacts. Artifact reduction and setup simplicity suggest a clinical advantage to data-driven 4D CT. Published by Elsevier Inc.

  4. Endoscopic ultrasonography in esophageal cancer leads to improved survival rates: results from a population-based study.

    PubMed

    Wani, Sachin; Das, Ananya; Rastogi, Amit; Drahos, Jennifer; Ricker, Winifred; Parsons, Ruth; Bansal, Ajay; Yen, Roy; Hosford, Lindsay; Jankowski, Meghan; Sharma, Prateek; Cook, Michael B

    2015-01-15

    The advantages of endoscopic ultrasound (EUS) and computed tomography (CT)-positron emission tomography (PET) with respect to survival for esophageal cancer patients are unclear. This study aimed to assess the effects of EUS, CT-PET, and their combination on overall survival with respect to cases not receiving these procedures. Patients who were ≥66 years old when diagnosed with esophageal cancer were identified in the Surveillance, Epidemiology, and End Results-Medicare linked database. Cases were split into 4 analytic groups: EUS only (n = 318), CT-PET only (n = 853), EUS+CT-PET (n = 189), and no EUS or CT-PET (n = 2439). Survival times were estimated with the Kaplan-Meier method and were compared with the log-rank test for each group versus the no EUS or CT-PET group. Multivariate Cox proportional hazards models were used to compare 1-, 3-, and 5-year survival rates. Kaplan-Meier analyses showed that EUS, CT-PET, and EUS+CT-PET patients had improved survival for all stages (with the exception of stage 0 disease) in comparison with patients undergoing no EUS or CT-PET. Receipt of EUS increased the likelihood of receiving endoscopic therapies, esophagectomy, and chemoradiation. Multivariate Cox proportional hazards models showed that receipt of EUS was a significant predictor of improved 1- (hazard ratio [HR], 0.49; 95% confidence interval [CI], 0.39-0.59; P < .0001), 3- (HR, 0.57; 95% CI, 0.48-0.66; P < .0001), and 5-year survival (HR, 0.59; 95% CI, 0.50-0.68). Similar results were noted when the results were stratified on the basis of histology and for the CT-PET and EUS+CT-PET groups. Receipt of either EUS or CT-PET alone in esophageal cancer patients was associated with improved 1-, 3-, and 5-year survival. Future studies should identify barriers to the dissemination of these staging modalities. © 2014 American Cancer Society.

  5. Trends in CT scan rates in children and pregnant women: teaching, private, public and nonprofit facilities.

    PubMed

    Hoshiko, Sumi; Smith, Daniel; Fan, Cathyn; Jones, Carrie R; McNeel, Sandra V; Cohen, Ronald A

    2014-05-01

    Radiation exposure from medical sources now equals or exceeds that from natural background sources, largely attributable to a 20-fold increase in CT use since 1980. Increasing exposure to children and fetuses is of most concern due to their heightened susceptibility. More recently, CT use may be leveling or decreasing, but it is unclear whether this change is widespread or varies by type of institution. We sought to characterize trends in CT utilization in California hospitals and emergency departments among children and pregnant women, looking at different types of facilities, such as teaching, private, public and nonprofit institutions. We examined frequency of CT examinations by year from 229 facilities reporting CT usage in routinely collected California statewide data for 2005-2012. We modeled trends overall and by facility type. CT scans for pediatric and pregnant patient visits in the emergency department increased initially, then started to decline after 2008. Among hospital admissions, rates declined or leveled after 2005. In the emergency department, CT rates varied between types of facilities, with teaching hospitals reducing use sooner and more sharply than other types of facilities. CT utilization in California among children and pregnant women has begun to level or decline. Still, population exposure remains at historically high levels, warranting consideration of potential public health implications. Further examination of reasons for trends among hospital types, particularly how teaching hospitals have reduced rates of CT utilization, may help identify strategies for CT reduction without compromising patient care.

  6. 77 FR 76597 - Petition for Waiver of Compliance

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-28

    ... fleet to the age exploration M7 waiver. FRA assigned the petition Docket Number FRA-2004-17099. MNR is...). The MNR M7 fleet is currently undergoing age exploration tests. The MNR M7 fleet is averaging 68,000... only those components not yet captured by the KB-CT1 (M7) age exploration testing in support of this...

  7. Disappearing renal calculus.

    PubMed

    Cui, Helen; Thomas, Johanna; Kumar, Sunil

    2013-04-10

    We present a case of a renal calculus treated solely with antibiotics which has not been previously reported in the literature. A man with a 17 mm lower pole renal calculus and concurrent Escherichia coli urine infection was being worked up to undergo percutaneous nephrolithotomy. However, after a course of preoperative antibiotics the stone was no longer seen on retrograde pyelography or CT imaging.

  8. Comparison of standard radiography and computed tomography in 21 dogs with maxillary masses.

    PubMed

    Ghirelli, Carolina O; Villamizar, Lenin A; Pinto, Ana Carolina B C Fonseca

    2013-01-01

    Imaging of patients with oral cancer is required to determine tumor extension in order to assist in prognosis and surgical planning. Conventional screen-film radiography (SFR) used to be the most common method for oral assessment, but computed tomography (CT) has become more available and is being used for obtaining complementary information. CT examinations eliminate superimposition by acquiring cross-sectional images of the region of interest. The objective of this study was to determine the diagnostic value of SFR compared with CT examinations for evaluation of oral masses in dogs. Twenty-one dogs received head and thorax SFR, and pre- and post-contrast head CT. Bony changes were observed in 80.9% and 95.2% of the cases in SFR and CT studies, respectively. Invasion of adjacent structures (i.e. nasal cavity, frontal and sphenoidal sinuses, orbit, maxillary recess, nasopharynx) was observed in only 30% of cases with SFR while CT showed 90.4% involvement. CT is an important preoperative examination modality and is more effective in identifying bone changes and tumor invasion of adjacent structures compared with SFR.

  9. Whole-body CT-based imaging algorithm for multiple trauma patients: radiation dose and time to diagnosis

    PubMed Central

    Gordic, S; Hodel, S; Simmen, H-P; Brueesch, M; Frauenfelder, T; Wanner, G; Sprengel, K

    2015-01-01

    Objective: To determine the number of imaging examinations, radiation dose and the time to complete trauma-related imaging in multiple trauma patients before and after introduction of whole-body CT (WBCT) into early trauma care. Methods: 120 consecutive patients before and 120 patients after introduction of WBCT into the trauma algorithm of the University Hospital Zurich were compared regarding the number and type of CT, radiography, focused assessment with sonography for trauma (FAST), additional CT examinations (defined as CT of the same body regions after radiography and/or FAST) and the time to complete trauma-related imaging. Results: In the WBCT cohort, significantly more patients underwent CT of the head, neck, chest and abdomen (p < 0.001) than in the non-WBCT cohort, whereas the number of radiographic examinations of the cervical spine, chest and pelvis and of FAST examinations were significantly lower (p < 0.001). There were no significant differences between cohorts regarding the number of radiographic examinations of the upper (p = 0.56) and lower extremities (p = 0.30). We found significantly higher effective doses in the WBCT (29.5 mSv) than in the non-WBCT cohort (15.9 mSv; p < 0.001), but fewer additional CT examinations for completing the work-up were needed in the WBCT cohort (p < 0.001). The time to complete trauma-related imaging was significantly shorter in the WBCT (12 min) than in the non-WBCT cohort (75 min; p < 0.001). Conclusion: Including WBCT in the initial work-up of trauma patients results in higher radiation doses, but fewer additional CT examinations are needed, and the time for completing trauma-related imaging is shorter. Advances in knowledge: WBCT in trauma patients is associated with a high radiation dose of 29.5 mSv. PMID:25594105

  10. Increased CCT-eta expression is a marker of latent and active disease and a modulator of fibroblast contractility in Dupuytren's contracture.

    PubMed

    Satish, Latha; O'Gorman, David B; Johnson, Sandra; Raykha, Christina; Gan, Bing Siang; Wang, James H-C; Kathju, Sandeep

    2013-07-01

    Dupuytren's contracture (DC) is a fibroproliferative disorder of unknown etiology characterized by a scar-like contracture that develops in the palm and/or digits. We have previously reported that the eta subunit of the chaperonin containing T-complex polypeptide (CCT-eta) is increased in fibrotic wound healing, and is essential for the accumulation of α-smooth muscle actin (α-SMA) in fibroblasts. The purpose of this study was to determine if CCT-eta is similarly implicated in the aberrant fibrosis seen in DC and to investigate the role of CCT-eta in the behavior of myo/fibroblasts in DC. Fibroblasts were obtained from DC-affected palmar fascia, from adjacent phenotypically normal palmar fascia in the same DC patients (PF), and from non-DC palmar fascial tissues in patients undergoing carpal tunnel (CT) release. Inherent contractility in these three populations was examined using fibroblast-populated collagen lattices (FPCLs) and by cell traction force microscopy. Expression of CCT-eta and α-SMA protein was determined by Western blot. The effect of CCT-eta inhibition on the contractility of DC cells was determined by deploying an siRNA versus CCT-eta. DC cells were significantly more contractile than both matching palmar fascial (PF) cells and CT cells in both assays, with PF cells demonstrating an intermediate contractility in the FPCL assay. Whereas α-SMA protein was significantly increased only in DC cells compared to PF and CT cells, CCT-eta protein was significantly increased in both PF and DC cells compared to CT cells. siRNA-mediated depletion of CCT-eta inhibited the accumulation of both CCT-eta and α-SMA protein in DC cells, and also significantly decreased the contractility of treated DC cells. These observations suggest that increased expression of CCT-eta appears to be a marker for latent and active disease in these patients and to be essential for the increased contractility exhibited by these fibroblasts.

  11. Diagnosis, treatment and prognosis of small bowel volvulus in adults: A monocentric summary of a rare small intestinal obstruction

    PubMed Central

    Li, Xiaohang; Zhang, Jialin; Li, Baifeng; Yi, Dehui; Zhang, Chengshuo; Sun, Ning; Lv, Wu; Jiao, Ao

    2017-01-01

    Objectives Small bowel volvulus is a rare disease, which is also challenging to diagnose. The aims of this study were to characterize the clinical and radiological features associated with small bowel volvulus and treatment and to identify risk factors for associated small bowel necrosis. Methods Patients with small bowel volvulus who underwent operations from January 2001 to December 2015 at the First Affiliated Hospital of China Medical University (Shenyang, China) were reviewed. Clinical, surgical and postsurgical data were registered and analyzed. Results Thirty-one patients were included for analysis. Fifteen patients were female (48.4%), with an average age of 47.7 years (18–79 years). The clinical signs and symptoms were unspecific and resembled intestinal obstruction. Clinical examination revealed abdominal distension and/or diffuse tenderness with or without signs of peritonitis. The use of CT scans, X-rays or ultrasound did not differ significantly between patients. In 9 of 20 patients that received abdominal CT scans, “whirlpool sign” on the CT scan was present. Secondary small bowel volvulus was present in 58.1% of patients, and causes included bands (3), adhesion (7), congenital anomalies (7) and stromal tumor (1). Out of the 31 patients, 15 with gangrenous small bowel had to undergo intestinal resection. Intestinal gangrene was present with higher neutrophils count (p<0.0001) and the presence of bloody ascites (p = 0.004). Three patients died of septic shock (9.68%), and the recurrence rate was 3.23%. Conclusions To complete an early and accurate diagnosis, a CT scan plus physical exam seems to be the best plan. After diagnosis, an urgent laparotomy must be performed to avoid intestinal necrosis and perforation. After surgery, more than 90% of the patients can expect to have a favorable prognosis. PMID:28426721

  12. Pre-operative localization of solitary pulmonary nodules with computed tomography-guided hook wire: report of 181 patients.

    PubMed

    Hanauer, Matthieu; Perentes, Jean Yannis; Krueger, Thorsten; Ris, Hans-Beat; Bize, Pierre; Schmidt, Sabine; Gonzalez, Michel

    2016-01-16

    Video-assisted thoracic surgery (VATS) is currently performed to diagnose and treat solitary pulmonary nodules (SPN). However, the intra-operative identification of deep nodules can be challenging with VATS as the lung is difficult to palpate. The aim of the study was to report the utility and the results of pre-operative computed tomography (CT)-guided hook wire localization of SPN. All records of the patients undergoing CT-guided hook wire localization prior to VATS resection for SPN between 2002 and 2013 were reviewed. The efficacy in localizing the nodule, hook wire complications, necessity to convert VATS to thoracotomy and the histology of SPN are reported. One hundred eighty-one patients (90 females, mean age 63 y, range 28-82 y) underwent 187 pulmonary resections after CT-guided hook wire localization. The mean SPN diameter was 10.3 mm (range: 4-29 mm). The mean distance of the lesion from the pleural surface was 11.6 mm (range: 0-45 mm). The mean time interval from hook wire insertion to VATS resection was 224 min (range 54-622 min). Hook wire complications included pneumothorax requiring chest tube drainage in 4 patients (2.1%) and mild parenchymal haemorrhage in 11 (5.9%) patients. Migration of the hook wire occurred in 7 patients (3.7%) although it did not affect the success of VATS resection (nodule location guided by the lung puncture site). Three patients underwent additional wedge resection by VATS during the same procedure because no lesion was identified in the surgical specimen. Conversion thoracotomy was required in 13 patients (7 %) for centrally localized lesions (6 patients) and pleural adhesions (7 patients). The mean operative time was 60 min (range 18-135 min). Pathological examination revealed a malignant lesion in 107 patients (59 %). The diagnostic yield was 98.3 %. VATS resection for SPN after CT-guided hook wire localization for SPN is safe and allows for proper diagnosis with a low thoracotomy conversion rate.

  13. SU-E-J-234: Application of a Breathing Motion Model to ViewRay Cine MR Images

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    O’Connell, D. P.; Thomas, D. H.; Dou, T. H.

    2015-06-15

    Purpose: A respiratory motion model previously used to generate breathing-gated CT images was used with cine MR images. Accuracy and predictive ability of the in-plane models were evaluated. Methods: Sagittalplane cine MR images of a patient undergoing treatment on a ViewRay MRI/radiotherapy system were acquired before and during treatment. Images were acquired at 4 frames/second with 3.5 × 3.5 mm resolution and a slice thickness of 5 mm. The first cine frame was deformably registered to following frames. Superior/inferior component of the tumor centroid position was used as a breathing surrogate. Deformation vectors and surrogate measurements were used to determinemore » motion model parameters. Model error was evaluated and subsequent treatment cines were predicted from breathing surrogate data. A simulated CT cine was created by generating breathing-gated volumetric images at 0.25 second intervals along the measured breathing trace, selecting a sagittal slice and downsampling to the resolution of the MR cines. A motion model was built using the first half of the simulated cine data. Model accuracy and error in predicting the remaining frames of the cine were evaluated. Results: Mean difference between model predicted and deformably registered lung tissue positions for the 28 second preview MR cine acquired before treatment was 0.81 +/− 0.30 mm. The model was used to predict two minutes of the subsequent treatment cine with a mean accuracy of 1.59 +/− 0.63 mm. Conclusion: Inplane motion models were built using MR cine images and evaluated for accuracy and ability to predict future respiratory motion from breathing surrogate measurements. Examination of long term predictive ability is ongoing. The technique was applied to simulated CT cines for further validation, and the authors are currently investigating use of in-plane models to update pre-existing volumetric motion models used for generation of breathing-gated CT planning images.« less

  14. On the effect of computed tomography resolution to distinguish between abdominal aortic aneurysm wall tissue and calcification: A proof of concept.

    PubMed

    Barrett, H E; Cunnane, E M; O Brien, J M; Moloney, M A; Kavanagh, E G; Walsh, M T

    2017-10-01

    The purpose of this study is to determine the optimal target CT spatial resolution for accurately imaging abdominal aortic aneurysm (AAA) wall characteristics, distinguishing between tissue and calcification components, for an accurate assessment of rupture risk. Ruptured and non-ruptured AAA-wall samples were acquired from eight patients undergoing open surgical aneurysm repair upon institutional review board approval and informed consent was obtained from all patients. Physical measurements of AAA-wall cross-section were made using scanning electron microscopy. Samples were scanned using high resolution micro-CT scanning. A resolution range of 15.5-155μm was used to quantify the influence of decreasing resolution on wall area measurements, in terms of tissue and calcification. A statistical comparison between the reference resolution (15.5μm) and multi-detector CT resolution (744μm) was also made. Electron microscopy examination of ruptured AAAs revealed extremely thin outer tissue structure <200μm in radial distribution which is supporting the aneurysm wall along with large areas of adjacent medial calcifications far greater in area than the tissue layer. The spatial resolution of 155μm is a significant predictor of the reference AAA-wall tissue and calcification area measurements (r=0.850; p<0.001; r=0.999; p<0.001 respectively). The tissue and calcification area at 155μm is correct within 8.8%±1.86 and 26.13%±9.40 respectively with sensitivity of 87.17% when compared to the reference. The inclusion of AAA-wall measurements, through the use of high resolution-CT will elucidate the variations in AAA-wall tissue and calcification distributions across the wall which may help to leverage an improved assessment of AAA rupture risk. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Impact of time-of-flight PET on quantification errors in MR imaging-based attenuation correction.

    PubMed

    Mehranian, Abolfazl; Zaidi, Habib

    2015-04-01

    Time-of-flight (TOF) PET/MR imaging is an emerging imaging technology with great capabilities offered by TOF to improve image quality and lesion detectability. We assessed, for the first time, the impact of TOF image reconstruction on PET quantification errors induced by MR imaging-based attenuation correction (MRAC) using simulation and clinical PET/CT studies. Standard 4-class attenuation maps were derived by segmentation of CT images of 27 patients undergoing PET/CT examinations into background air, lung, soft-tissue, and fat tissue classes, followed by the assignment of predefined attenuation coefficients to each class. For each patient, 4 PET images were reconstructed: non-TOF and TOF both corrected for attenuation using reference CT-based attenuation correction and the resulting 4-class MRAC maps. The relative errors between non-TOF and TOF MRAC reconstructions were compared with their reference CT-based attenuation correction reconstructions. The bias was locally and globally evaluated using volumes of interest (VOIs) defined on lesions and normal tissues and CT-derived tissue classes containing all voxels in a given tissue, respectively. The impact of TOF on reducing the errors induced by metal-susceptibility and respiratory-phase mismatch artifacts was also evaluated using clinical and simulation studies. Our results show that TOF PET can remarkably reduce attenuation correction artifacts and quantification errors in the lungs and bone tissues. Using classwise analysis, it was found that the non-TOF MRAC method results in an error of -3.4% ± 11.5% in the lungs and -21.8% ± 2.9% in bones, whereas its TOF counterpart reduced the errors to -2.9% ± 7.1% and -15.3% ± 2.3%, respectively. The VOI-based analysis revealed that the non-TOF and TOF methods resulted in an average overestimation of 7.5% and 3.9% in or near lung lesions (n = 23) and underestimation of less than 5% for soft tissue and in or near bone lesions (n = 91). Simulation results showed that as TOF resolution improves, artifacts and quantification errors are substantially reduced. TOF PET substantially reduces artifacts and improves significantly the quantitative accuracy of standard MRAC methods. Therefore, MRAC should be less of a concern on future TOF PET/MR scanners with improved timing resolution. © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  16. Research on radiation exposure from CT part of hybrid camera and diagnostic CT

    NASA Astrophysics Data System (ADS)

    Solný, Pavel; Zimák, Jaroslav

    2014-11-01

    Research on radiation exposure from CT part of hybrid camera in seven different Departments of Nuclear Medicine (DNM) was conducted. Processed data and effective dose (E) estimations led to the idea of phantom verification and comparison of absorbed doses and software estimation. Anonymous data from about 100 examinations from each DNM was gathered. Acquired data was processed and utilized by dose estimation programs (ExPACT, ImPACT, ImpactDose) with respect to the type of examination and examination procedures. Individual effective doses were calculated using enlisted programs. Preserving the same procedure in dose estimation process allows us to compare the resulting E. Some differences and disproportions during dose estimation led to the idea of estimated E verification. Consequently, two different sets of about 100 of TLD 100H detectors were calibrated for measurement inside the Aldersnon RANDO Anthropomorphic Phantom. Standard examination protocols were examined using a 2 Slice CT- part of hybrid SPECT/CT. Moreover, phantom exposure from body examining protocol for 32 Slice and 64 Slice diagnostic CT scanner was also verified. Absorbed dose (DT,R) measured using TLD detectors was compared with software estimation of equivalent dose HT values, computed by E estimation software. Though, only limited number of cavities for detectors enabled measurement within the regions of lung, liver, thyroid and spleen-pancreas region, some basic comparison is possible.

  17. Dose reduction with adaptive statistical iterative reconstruction for paediatric CT: phantom study and clinical experience on chest and abdomen CT.

    PubMed

    Gay, F; Pavia, Y; Pierrat, N; Lasalle, S; Neuenschwander, S; Brisse, H J

    2014-01-01

    To assess the benefit and limits of iterative reconstruction of paediatric chest and abdominal computed tomography (CT). The study compared adaptive statistical iterative reconstruction (ASIR) with filtered back projection (FBP) on 64-channel MDCT. A phantom study was first performed using variable tube potential, tube current and ASIR settings. The assessed image quality indices were the signal-to-noise ratio (SNR), the noise power spectrum, low contrast detectability (LCD) and spatial resolution. A clinical retrospective study of 26 children (M:F = 14/12, mean age: 4 years, range: 1-9 years) was secondarily performed allowing comparison of 18 chest and 14 abdominal CT pairs, one with a routine CT dose and FBP reconstruction, and the other with 30 % lower dose and 40 % ASIR reconstruction. Two radiologists independently compared the images for overall image quality, noise, sharpness and artefacts, and measured image noise. The phantom study demonstrated a significant increase in SNR without impairment of the LCD or spatial resolution, except for tube current values below 30-50 mA. On clinical images, no significant difference was observed between FBP and reduced dose ASIR images. Iterative reconstruction allows at least 30 % dose reduction in paediatric chest and abdominal CT, without impairment of image quality. • Iterative reconstruction helps lower radiation exposure levels in children undergoing CT. • Adaptive statistical iterative reconstruction (ASIR) significantly increases SNR without impairing spatial resolution. • For abdomen and chest CT, ASIR allows at least a 30 % dose reduction.

  18. Radiological diagnosis of gas gangrene in a fetus at term.

    PubMed

    Abe, Kanako; Hamada, Hiromi; Fujiki, Yutaka; Iiba, Moe; Tenjimbayashi, Yuri; Yoshikawa, Hiroyuki

    2016-08-01

    To report a case of gas gangrene in a fetus at term, which was diagnosed by antenatal computed tomography (CT) imaging. A 23-year-old primiparous woman, who did not undergo any prenatal health checks until term, developed hypertension, proteinuria, and clouding of consciousness, and experienced intrauterine fetal death. A single, mature fetus with voluminous gas bubbles was observed on CT, which was consistent with a diagnosis of fetal gas gangrene. Following the induction of labor, a dead, malodorous infant was delivered, along with foul-smelling and frothy amniotic fluid. The patient's condition deteriorated, and intensive care support was required to treat the patient for septic shock and disseminated intravascular coagulation during the postpartum period. She died on the 2(nd) postpartum day. Fetal gas gangrene is a very rare and potentially lethal event in pregnant women. To our knowledge, this is the first report on the antenatal diagnosis of fetal gas gangrene in a term pregnancy through CT. CT was useful for evaluating the extent of emphysematous change in the fetal and maternal organs. Copyright © 2016. Published by Elsevier B.V.

  19. [Has high-definition spiral computed tomography changed the management of patients with acute pulmonary embolism?].

    PubMed

    Pesavento, Raffaele; de Conti, Giorgio; Minotto, Isabella; Prandoni, Paolo

    2008-12-01

    Pulmonary embolism (PE) is a common condition carrying a significant degree of mortality if not diagnosed early. The diagnosis of PE is challenging, because of the non-specific nature of its clinical features. For many years the diagnostic strategies for PE have mainly involved ventilation/perfusion lung scan as the chief diagnostic procedure, often associated with a few clinical models of pre-test probability and the D-dimer test. These modalities of diagnosing PE, though quite satisfactory in various clinical settings, show several limitations, the most important one being the high rate of non-diagnostic procedures. The introduction of computed tomography (CT) has changed the diagnostic strategies and has become the main diagnostic procedure for diagnosing PE. CT is undergoing a rapid technological upgrade, which will open in the near future new frontiers in the diagnosis of PE. Nonetheless, CT carries a number of limitations, which should be carefully identified. This article reviews the evidences on both the traditional and newer diagnostic strategies for PE, outlines their strengths and weaknesses and describes future applications of CT for diagnosing PE.

  20. Use and accuracy of diagnostic imaging in the evaluation of pediatric appendicitis.

    PubMed

    Kotagal, Meera; Richards, Morgan K; Flum, David R; Acierno, Stephanie P; Weinsheimer, Robert L; Goldin, Adam B

    2015-04-01

    There are safety concerns about the use of radiation-based imaging (computed tomography [CT]) to diagnose appendicitis in children. Factors associated with CT use remain to be determined. For patients ≤18 years old undergoing appendectomy, we evaluated diagnostic imaging performed, patient characteristics, hospital type, and imaging/pathology concordance (2008-2012) using data from Washington State's Surgical Care and Outcomes Assessment Program. Among 2538 children, 99.7% underwent pre-operative imaging. 52.7% had a CT scan as their first study. After adjustment, age >10 years (OR 2.9 (95% CI 2.2-4.0), Hispanic ethnicity (OR 1.7, 95% CI 1.5-1.9), and being obese (OR 1.7, 95% CI 1.4-2.1) were associated with CT use first. Evaluation at a non-children's hospital was associated with higher odds of CT use (OR 7.9, 95% CI 7.5-8.4). Ultrasound concordance with pathology was higher for males (72.3 vs. 66.4%, p=.03), in perforated appendicitis (75.9 vs. 67.5%, p=.009), and at children's hospitals compared to general adult hospitals (77.3 vs. 62.2%, p<.001). CT use has decreased yearly statewide. Over 50% of children with appendicitis had radiation-based imaging. Understanding factors associated with CT use should allow for more specific QI interventions to reduce radiation exposure. Site of care remains a significant factor in radiation exposure for children. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. The effect of respiratory motion on pulmonary nodule location during electromagnetic navigation bronchoscopy.

    PubMed

    Chen, Alexander; Pastis, Nicholas; Furukawa, Brian; Silvestri, Gerard A

    2015-05-01

    Electromagnetic navigation has improved the diagnostic yield of peripheral bronchoscopy for pulmonary nodules. For these procedures, a thin-slice chest CT scan is performed prior to bronchoscopy at full inspiration and is used to create virtual airway reconstructions that are used as a map during bronchoscopy. Movement of the lung occurs with respiratory variation during bronchoscopy, and the location of pulmonary nodules during procedures may differ significantly from their location on the initial planning full-inspiratory chest CT scan. This study was performed to quantify pulmonary nodule movement from full inspiration to end-exhalation during tidal volume breathing in patients undergoing electromagnetic navigation procedures. A retrospective review of electromagnetic navigation procedures was performed for which two preprocedure CT scans were performed prior to bronchoscopy. One CT scan was performed at full inspiration, and a second CT scan was performed at end-exhalation during tidal volume breathing. Pulmonary lesions were identified on both CT scans, and distances between positions were recorded. Eighty-five pulmonary lesions were identified in 46 patients. Average motion of all pulmonary lesions was 17.6 mm. Pulmonary lesions located in the lower lobes moved significantly more than upper lobe nodules. Size and distance from the pleura did not significantly impact movement. Significant movement of pulmonary lesions occurs between full inspiration and end-exhalation during tidal volume breathing. This movement from full inspiration on planning chest CT scan to tidal volume breathing during bronchoscopy may significantly affect the diagnostic yield of electromagnetic navigation bronchoscopy procedures.

  2. Accuracy of Monte Carlo simulations compared to in-vivo MDCT dosimetry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bostani, Maryam, E-mail: mbostani@mednet.ucla.edu; McMillan, Kyle; Cagnon, Chris H.

    Purpose: The purpose of this study was to assess the accuracy of a Monte Carlo simulation-based method for estimating radiation dose from multidetector computed tomography (MDCT) by comparing simulated doses in ten patients to in-vivo dose measurements. Methods: MD Anderson Cancer Center Institutional Review Board approved the acquisition of in-vivo rectal dose measurements in a pilot study of ten patients undergoing virtual colonoscopy. The dose measurements were obtained by affixing TLD capsules to the inner lumen of rectal catheters. Voxelized patient models were generated from the MDCT images of the ten patients, and the dose to the TLD for allmore » exposures was estimated using Monte Carlo based simulations. The Monte Carlo simulation results were compared to the in-vivo dose measurements to determine accuracy. Results: The calculated mean percent difference between TLD measurements and Monte Carlo simulations was −4.9% with standard deviation of 8.7% and a range of −22.7% to 5.7%. Conclusions: The results of this study demonstrate very good agreement between simulated and measured doses in-vivo. Taken together with previous validation efforts, this work demonstrates that the Monte Carlo simulation methods can provide accurate estimates of radiation dose in patients undergoing CT examinations.« less

  3. Improving perceptions of empathy in patients undergoing low-yield computerized tomographic imaging in the emergency department.

    PubMed

    Lin, Michelle P; Probst, Marc A; Puskarich, Michael A; Dehon, Erin; Kuehl, Damon R; Wang, Ralph C; Hess, Erik P; Butler, Katie; Runyon, Michael S; Wang, Hao; Courtney, D Mark; Muckley, Brandon; Hobgood, Cherri D; Hall, Cassandra L; Kline, Jeffrey A

    2018-04-01

    We assessed emergency department (ED) patient perceptions of how physicians can improve their language to determine patient preferences for 11 phrases to enhance physician empathy toward the goal of reducing low-value advanced imaging. Multi-center survey study of low-risk ED patients undergoing computerized tomography (CT) scanning. We enroled 305 participants across nine sites. The statement "I have carefully considered what you told me about what brought you here today" was most frequently rated as important (88%). The statement "I have thought about the cost of your medical care to you today" was least frequently rated as important (59%). Participants preferred statements indicating physicians had considered their "vital signs and physical examination" (86%), "past medical history" (84%), and "what prior research tells me about your condition" (79%). Participants also valued statements conveying risks of testing, including potential kidney injury (78%) and radiation (77%). The majority of phrases were identified as important. Participants preferred statements conveying cognitive reassurance, medical knowledge and risks of testing. Our findings suggest specific phrases have the potential to enhance ED patient perceptions of physician empathy. Further research is needed to determine whether statements to convey empathy affect diagnostic testing rates. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Development of a Radiation Dose Reporting Software for X-ray Computed Tomography (CT)

    NASA Astrophysics Data System (ADS)

    Ding, Aiping

    X-ray computed tomography (CT) has experienced tremendous technological advances in recent years and has established itself as one of the most popular diagnostic imaging tools. While CT imaging clearly plays an invaluable role in modern medicine, its rapid adoption has resulted in a dramatic increase in the average medical radiation exposure to the worldwide and United States populations. Existing software tools for CT dose estimation and reporting are mostly based on patient phantoms that contain overly simplified anatomies insufficient in meeting the current and future needs. This dissertation describes the development of an easy-to-use software platform, “VirtualDose”, as a service to estimate and report the organ dose and effective dose values for patients undergoing the CT examinations. “VirtualDose” incorporates advanced models for the adult male and female, pregnant women, and children. To cover a large portion of the ignored obese patients that frequents the radiology clinics, a new set of obese male and female phantoms are also developed and applied to study the effects of the fat tissues on the CT radiation dose. Multi-detector CT scanners (MDCT) and clinical protocols, as well as the most recent effective dose algorithms from the International Commission on Radiological Protection (ICRP) Publication 103 are adopted in “VirtualDose” to keep pace with the MDCT development and regulatory requirements. A new MDCT scanner model with both body and head bowtie filter is developed to cover both the head and body scanning modes. This model was validated through the clinical measurements. A comprehensive slice-by-slice database is established by deriving the data from a larger number of single axial scans simulated on the patient phantoms using different CT bowtie filters, beam thicknesses, and different tube voltages in the Monte Carlo N-Particle Extended (MCNPX) code. When compared to the existing CT dose software packages, organ dose data in this software provides a better CT dose assessment by using anatomically realistic patient phantoms. All the related organ doses are incorporated into a standardized database compiled using Microsoft Structured Query Language (SQL) server 2008. Organ doses from contiguous axial or helical scans defined by a specific protocol can be rapidly obtained from the database. A next-generation software architecture and Active Server Pages (ASP) .NET framework are adopted to create a browser-hosted application to improve the user interactivity and reporting functionality including scanning parameter selection and organ dose reporting. “VirtualDose” has been developed as a web-based CT dose reporting platform to facilitate several important features including: (1) easy access via Internet; (2) no need for installation on the local computer; (3) a user-friendly, dynamic, browser-hosted graphical user interface; (4) use of advanced patient models for the adult male and female, pregnant women, children, and obese patient models; (5) adoption of modern CT scanners and protocols, as well as the most recent ICRP 103 effective dose algorithms; and (6) flexibility to manage and easily upgrade without impacting user’s usage.

  5. [Evaluation of the knowledge of physicians prescribing CT examinations on the radiation protection of patients].

    PubMed

    Gervaise, A; Esperabe-Vignau, F; Pernin, M; Naulet, P; Portron, Y; Lapierre-Combes, M

    2011-01-01

    To evaluate the knowledge of physicians prescribing CT examinations on the radiation protection of patients. A questionnaire was distributed to all clinicians on medical staff who prescribe CT examinations. Several questions related to their prescription pattern and their knowledge of radiation protection. Forty-four questionnaires were analyzed. While 70% of physicians claimed that they considered the risks from exposure to ionizing radiation when prescribing a CT examination, only 25% informed their patients about those risks. Knowledge of the radiation dose delivered during CT evaluation of the abdomen and pelvis was poorly understood and the risks related to small doses of radiation were grossly underestimated. Finally, only a third of clinicians had received training with regards to radiation protection. While most clinicians claim that they consider the risks from exposure to ionizing radiation when prescribing a CT examination, the risks are either not well known or not known at all. Increased formation of clinicians with regards to the radiation protection of patients, maybe through a dedicated clinical rotation while in medical school, could be a solution to improve the knowledge of hospital clinicians with regards to radiation protection. Copyright © 2011 Elsevier Masson SAS and Éditions françaises de radiologie. All rights reserved.

  6. University of Hawai‘i Cancer Center Connection

    PubMed Central

    Halm, Brunhild M; Lai, Jennifer F; Li, Xingnan; Custer, Laurie J; Pagano, Ian; Cooney, Robert V; Turner, Helen C; Brenner, David J

    2015-01-01

    Computed tomography (CT) is an imaging modality that exposes patients to ionizing radiation (IR). We review and report findings from our pilot study evaluating whether blood markers are altered in 17 children undergoing medically indicated CT scans. Blood was drawn before (‘pre-CT’) and 1 hour after (‘post-CT’ CT scans. Plasma carotenoids, tocopherols, Q10, ascorbic acid (AA) and uric acid (UA) were analyzed by RP-HPLC with diode-array and electrochemical detection. Dehydroascorbic acid (DHAA) was calculated by subtraction from total AA. Total antioxidant capacity (TAC) was measured using the ORAC assay. Cytokines were quantified using a multiplex immunoassay. γ-H2AX foci were visualized using immunofluorescence. Mean pre- and post-CT changes were compared using t-tests; P-levels < .05 indicated significance. All major plasma lipid soluble antioxidant levels were lower post- vs pre-CT (P < .05) possibly from the scavenging of free radicals formed by CT-induced IR. Average AA levels increased (134%) while DHAA levels were decreased (29%) post-CT, probably due to intracellular recycling of AA from DHAA. TAC levels in lipophilic and hydrophilic extracts were unchanged, suggesting that other antioxidants may have assisted in free radical quenching, which would corroborate their lower concentrations post-CT. Cytokine levels were unchanged and dose-dependent increases in γ-H2AX foci, a measure of double strand DNA breaks, were observed (P = .046, n = 3 children). Our results suggest that CT-derived IR can influence the antioxidant system and may elicit detrimental responses on the cellular level of young children. When possible and if appropriate non-IR based techniques such as ultrasound or magnetic resonance imaging should be used. PMID:25821654

  7. A single CT for attenuation correction of both rest and stress SPECT myocardial perfusion imaging: a retrospective feasibility study

    PubMed Central

    Ahlman, Mark A; Nietert, Paul J; Wahlquist, Amy E; Serguson, Jill M; Berry, Max W; Suranyi, Pal; Liu, Songtao; Spicer, Kenneth M

    2014-01-01

    Purpose: In the effort to reduce radiation exposure to patients undergoing myocardial perfusion imaging (MPI) with SPECT/CT, we evaluate the feasibility of a single CT for attenuation correction (AC) of single-day rest (R)/stress (S) perfusion. Methods: Processing of 20 single isotope and 20 dual isotope MPI with perfusion defects were retrospectively repeated in three steps: (1) the standard method using a concurrent R-CT for AC of R-SPECT and S-CT for S-SPECT; (2) the standard method repeated; and (3) with the R-CT used for AC of S-SPECT, and the S-CT used for AC of R-SPECT. Intra-Class Correlation Coefficients (ICC) and Choen’s kappa were used to measure intra-operator variability in sum scoring. Results: The highest level of intra-operator reliability was seen with the reproduction of the sum rest score (SRS) and sum stress score (SSS) (ICC > 95%). ICCs were > 85% for SRS and SSS when alternate CTs were used for AC, but when sum difference scores were calculated, ICC values were much lower (~22% to 27%), which may imply that neither CT substitution resulted in a reproducible difference score. Similar results were seen when evaluating dichotomous outcomes (sum scores difference of ≥ 4) when comparing different processing techniques (kappas ~0.32 to 0.43). Conclusions: When a single CT is used for AC of both rest and stress SPECT, there is disproportionately high variability in sum scoring that is independent of user error. This information can be used to direct further investigation in radiation reduction for common imaging exams in nuclear medicine. PMID:24482701

  8. Longitudinal studies of the 18F-FDG kinetics after ipilimumab treatment in metastatic melanoma patients based on dynamic FDG PET/CT.

    PubMed

    Sachpekidis, Christos; Anwar, Hoda; Winkler, Julia K; Kopp-Schneider, Annette; Larribere, Lionel; Haberkorn, Uwe; Hassel, Jessica C; Dimitrakopoulou-Strauss, Antonia

    2018-06-05

    Immunotherapy has raised the issue of appropriate treatment response evaluation, due to the unique mechanism of action of the immunotherapeutic agents. Aim of this analysis is to evaluate the potential role of quantitative analysis of 2-deoxy-2-( 18 F)fluoro-D-glucose ( 18 F-FDG) positron emission tomography/computed tomography (PET/CT) data in monitoring of patients with metastatic melanoma undergoing ipilimumab therapy. 25 patients with unresectable metastatic melanoma underwent dynamic PET/CT (dPET/CT) of the thorax and upper abdomen as well as static, whole body PET/CT with 18 F-FDG before the start of ipilimumab treatment (baseline PET/CT), after two cycles of treatment (interim PET/CT) and at the end of treatment after four cycles (late PET/CT). The evaluation of dPET/CT studies was based on semi-quantitative (standardized uptake value, SUV) calculation as well as quantitative analysis, based on two-tissue compartment modeling and a fractal approach. Patients' best clinical response, assessed at a mean of 59 weeks, was used as reference. According to their best clinical response, patients were dichotomized in those demonstrating clinical benefit (CB, n = 16 patients) and those demonstrating no clinical benefit (no-CB, n = 9 patients). No statistically significant differences were observed between CB and no-CB regarding either semi-quantitative or quantitative parameters in all scans. On contrary, the application of the recently introduced PET response evaluation criteria for immunotherapy (PERCIMT) led to a correct classification rate of 84% (21/25 patients). Quantitative analysis of 18 F-FDG PET data does not provide additional information in treatment response evaluation of metastatic melanoma patients receiving ipilimumab. PERCIMT criteria correlated better with clinical response.

  9. Differential expression of circulating Th1/ Th2/ Th17 cytokines in serum of Chlamydia trachomatis-infected women undergoing incomplete spontaneous abortion.

    PubMed

    Prasad, Priya; Singh, Namita; Das, Banashree; Raisuddin, Sheikh; Dudeja, Mridu; Rastogi, Sangita

    2017-09-01

    The study aimed to elucidate role of Th1/Th2/Th17 cytokines in the immunopathogenesis of spontaneous abortion in Chlamydia trachomatis (Ct)-positive first-trimester aborters. Endometrial curettage tissue and serum were collected from 145 aborters (spontaneous abortion (SA) group, n = 85; recurrent miscarriage (RM) group, n = 60) and 120 controls attending Department of Obstetrics & Gynecology at Safdarjung hospital, New Delhi (India). Polymerase chain reaction was used to detect Ct plasmid/MOMP, while commercial cytometric bead array kit was utilized to estimate circulating serum cytokines. 13.7% aborters were Ct-positive, however, none was found to be infected among controls. IFN-γ, TNF-α, IL-2, IL-6 and IL-17A cytokines were significantly increased in SA group/RM group (Ct-infected) versus controls. IL-4 showed no difference between groups, while IL-10 was significantly elevated in controls versus Ct-infected subjects in SA group/RM group. Furthermore, IFN-γ, TNF-α, IL-6, IL-17A cytokines were significantly elevated in Ct-positive RM group versus Chlamydia-infected SA group. However, IL-2, IL-4 and IL-10 cytokines showed no significant difference between Ct-positive SA group versus infected RM group. Positive correlation was found between few cytokines (TNF-α and IFN-γ/IL-17A; IL-17A and IFN-γ/IL-6) in Ct-positive aborters. Our study clearly established the role of Th1/Th2/Th17 cytokines in the pathogenesis of spontaneous abortion in Ct-infected subjects and found that Chlamydia-positive recurrent aborters had a predominant Th1/Th17 bias. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Early detection of lung cancer using ultra-low-dose computed tomography in coronary CT angiography scans among patients with suspected coronary heart disease.

    PubMed

    Zanon, Matheus; Pacini, Gabriel Sartori; de Souza, Vinicius Valério Silveiro; Marchiori, Edson; Meirelles, Gustavo Souza Portes; Szarf, Gilberto; Torres, Felipe Soares; Hochhegger, Bruno

    2017-12-01

    To assess whether an additional chest ultra-low-dose CT scan to the coronary CT angiography protocol can be used for lung cancer screening among patients with suspected coronary artery disease. 175 patients underwent coronary CT angiography for assessment of coronary artery disease, additionally undergoing ultra-low-dose CT screening to early diagnosis of lung cancer in the same scanner (80kVp and 15mAs). Patients presenting pulmonary nodules were followed-up for two years, repeating low-dose CTs in intervals of 3, 6, or 12 months based on nodule size and growth rate in accordance with National Comprehensive Cancer Network guidelines. Ultra-low-dose CT identified 71 patients with solitary pulmonary nodules (41%), with a mean diameter of 5.50±4.00mm. Twenty-eight were >6mm, and in 79% (n=22) of these cases they were false positive findings, further confirmed by follow-up (n=20), resection (n=1), or biopsy (n=1). Lung cancer was detected in six patients due to CT screening (diagnostic yield: 3%). Among these, four cases could not be detected in the cardiac field of view. Most patients were in early stages of the disease. Two patients diagnosed at advanced stages died due to cancer complications. The addition of the ultra-low-dose CT scan represented a radiation dose increment of 1.22±0.53% (effective dose, 0.11±0.03mSv). Lung cancer might be detected using additional ultra-low-dose protocols in coronary CT angiography scans among patients with suspected coronary artery disease. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Emergency ultrasound-based algorithms for diagnosing blunt abdominal trauma.

    PubMed

    Stengel, Dirk; Bauwens, Kai; Rademacher, Grit; Ekkernkamp, Axel; Güthoff, Claas

    2013-07-31

    Ultrasonography is regarded as the tool of choice for early diagnostic investigations in patients with suspected blunt abdominal trauma. Although its sensitivity is too low for definite exclusion of abdominal organ injury, proponents of ultrasound argue that ultrasound-based clinical pathways enhance the speed of primary trauma assessment, reduce the number of computed tomography scans and cut costs. To assess the effects of trauma algorithms that include ultrasound examinations in patients with suspected blunt abdominal trauma. We searched the Cochrane Injuries Group's Specialised Register, CENTRAL (The Cochrane Library), MEDLINE (OvidSP), EMBASE (OvidSP), CINAHL (EBSCO), publishers' databases, controlled trials registers and the Internet. Bibliographies of identified articles and conference abstracts were searched for further elligible studies. Trial authors were contacted for further information and individual patient data. The searches were updated in February 2013. randomised controlled trials (RCTs) and quasi-randomised trials (qRCTs). patients with blunt torso, abdominal or multiple trauma undergoing diagnostic investigations for abdominal organ injury. diagnostic algorithms comprising emergency ultrasonography (US). diagnostic algorithms without ultrasound examinations (for example, primary computed tomography [CT] or diagnostic peritoneal lavage [DPL]). mortality, use of CT and DPL, cost-effectiveness, laparotomy and negative laparotomy rates, delayed diagnoses, and quality of life. Two authors independently selected trials for inclusion, assessed methodological quality and extracted data. Where possible, data were pooled and relative risks (RRs), risk differences (RDs) and weighted mean differences, each with 95% confidence intervals (CIs), were calculated by fixed- or random-effects modelling, as appropriate. We identified four studies meeting our inclusion criteria. Overall, trials were of moderate methodological quality. Few trial authors responded to our written inquiries seeking to resolve controversial issues and to obtain individual patient data. We pooled mortality data from three trials involving 1254 patients; relative risk in favour of the US arm was 1.00 (95% CI 0.50 to 2.00). US-based pathways significantly reduced the number of CT scans (random-effects RD -0.52, 95% CI -0.83 to -0.21), but the meaning of this result is unclear. Given the low sensitivity of ultrasound, the reduction in CT scans may either translate to a number needed to treat or number needed to harm of two. There is currently insufficient evidence from RCTs to justify promotion of ultrasound-based clinical pathways in diagnosing patients with suspected blunt abdominal trauma.

  12. Assessment of dose and DNA damages in individuals exposed to low dose and low dose rate ionizing radiations during computed tomography imaging.

    PubMed

    Kanagaraj, Karthik; Abdul Syed Basheerudeen, Safa; Tamizh Selvan, G; Jose, M T; Ozhimuthu, Annalakshmi; Panneer Selvam, S; Pattan, Sudha; Perumal, Venkatachalam

    2015-08-01

    Computed tomography (CT) is a frequently used imaging modality that contributes to a tenfold increase in radiation exposure to the public when compared to other medical imaging modalities. The use of radiation for therapeutic need is always rationalized on the basis of risk versus benefit thereby increasing concerns on the dose received by patients undergoing CT imaging. Therefore, it was of interest to us to investigate the effects of low dose and low dose-rate X-irradiation in patients who underwent CT imaging by recording the doses received by the eye, forehead and thyroid, and to study the levels of damages in the lymphocytes in vivo. Lithium manganese borate doped with terbium (LMB:Tb) thermo luminescence dosimeters (TLD) were used to record the doses in the patient's (n = 27) eye, forehead, and thyroid and compared with the dose length product (DLP) values. The in vivo DNA damages measured were compared before and after CT imaging using chromosomal aberration (CA) and micronucleus (MN) assays. The overall measured organ dose ranged between 2 ± 0.29 and 520 ± 41.63 mGy for the eye, 0.84 ± 0.29 and 210 ± 20.50 mGy for the forehead, and 1.79 ± 0.43 and 185 ± 0.70 mGy for the thyroid. The in vivo damages measured from the blood lymphocytes of the subjects showed an extremely significant (p < 0.0001) increase in CA frequency and significant (p < 0.001) increase in MN frequency after exposure, compared to before exposure. The results suggest that CT imaging delivers a considerable amount of radiation dose to the eye, forehead, and thyroid, and the observed increase in the CA and MN frequencies show low dose radiation effects calling for protective regulatory measures to increase patient's safety. This study is the first attempt to indicate the trend of doses received by the patient's eye, forehead and thyroid and measured directly in contrast to earlier values obtained by extrapolation from phantoms, and to assess the in vivo low dose effects in an Indian patient population undergoing CT procedures. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Evaluation of the stability of the stereotactic Leksell Frame G in Gamma Knife radiosurgery.

    PubMed

    Rojas-Villabona, Alvaro; Miszkiel, Katherine; Kitchen, Neil; Jäger, Rolf; Paddick, Ian

    2016-05-08

    The purpose of this study was to evaluate the stability of the Leksell Frame G in Gamma Knife radiosurgery (GKR). Forty patients undergoing GKR underwent pretreatment stereotactic MRI for GKR planning and stereotactic CT immediately after GKR. The stereotactic coordinates of four anatomical landmarks (cochlear apertures and the summits of the anterior post of the superior semicircular canals, bilaterally) were measured by two evaluators on two separate occasions in the pre-treatment MRI and post-treatment CT scans and the absolute distance between the observations is reported. The measurement method was validated with an indepen-dent group of patients who underwent both stereotactic MRI and CT imaging before treatment (negative controls; n: 5). Patients undergoing GKR for arteriovenous malformations (AVM) also underwent digital subtraction angiography (DSA), which could result in extra stresses on the frame. The distance between landmark local-ization in the scans for the negative control group (0.63 mm; 95% CI: 0.57-0.70; SD: 0.29) represents the overall consistency of the evaluation method and provides an estimate of the minimum displacement that could be detected by the study. Two patients in the study group had the fiducial indicator box accidentally misplaced at post-treatment CT scanning. This simulated the scenario of a frame displacement, and these cases were used as positive controls to demonstrate that the evaluation method is capable of detecting a discrepancy between the MRI and CT scans, if there was one. The mean distance between the location of the landmarks in the pretreatment MRI and post-treatment CT scans for the study group was 0.71 mm (95% CI: 0.68-0.74; SD:0.32), which was not statistically different from the over-all uncertainty of the evaluation method observed in the negative control group (p = 0.06). The subgroup of patients with AVM (n: 9), who also underwent DSA, showed a statistically significant difference between the location of the landmarks compared to subjects with no additional imaging: 0.78 mm (95% CI: 0.72-0.84) vs. 0.69 mm (95% CI: 0.66-0.72), p = 0.016. This is however a minimal differ-ence (0.1 mm) and the mean difference in landmark location for each AVM patient remained submillimeter. This study demonstrates submillimeter stability of the Leksell Frame G in GKR throughout the treatment procedure.

  14. Pretreatment with diphenoxylate hydrochloride/atropine sulfate (Lomotil) does not decrease physiologic bowel FDG activity on PET/CT scans of the abdomen and pelvis.

    PubMed

    Murphy, Robert; Doerger, Kirk M; Nathan, Mark A; Lowe, Val J

    2009-01-01

    Physiologic uptake of 2-[(18)F]-fluoro-2-deoxy-D: -glucose (FDG) by bowel can confound positron emission tomography/computed tomography (PET/CT) assessment for abdominal pathology, particularly within the bowel itself. We wished to determine if oral administration of the antimotility agent, Lomotil (5 mg diphenoxylate hydrochloride/0.05 mg atropine sulfate; G.D. Searle and Company, a division of Pfizer), prior to PET/CT scanning would reduce physiologic uptake of FDG by the small bowel and colon (lower gastrointestinal [GI] tract). Patients undergoing PET/CT scans for lymphoma were enrolled in a prospective, randomized, double-blinded study and received either 10 mL water (control group) or 10 mL Lomotil (experimental group) orally 30-60 min prior to scanning. Scans were reviewed independently by two blinded experienced readers and scored for the degree of FDG activity in the lower GI tract relative to liver activity. The administration of Lomotil prior to PET/CT scanning did not reduce physiologic FDG activity in the small bowel and colon. In contrast, increased radiotracer uptake by the lower GI tract was observed in the Lomotil group compared to the control group. Pretreatment with Lomotil prior to PET/CT scanning confers no benefit toward the reduction of physiologic FDG uptake by the small bowel and colon.

  15. Enumeration and targeted analysis of KRAS, BRAF and PIK3CA mutations in CTCs captured by a label-free platform: Comparison to ctDNA and tissue in metastatic colorectal cancer.

    PubMed

    Kidess-Sigal, Evelyn; Liu, Haiyan E; Triboulet, Melanie M; Che, James; Ramani, Vishnu C; Visser, Brendan C; Poultsides, George A; Longacre, Teri A; Marziali, Andre; Vysotskaia, Valentina; Wiggin, Matthew; Heirich, Kyra; Hanft, Violet; Keilholz, Ulrich; Tinhofer, Ingeborg; Norton, Jeffrey A; Lee, Mark; Sollier-Christen, Elodie; Jeffrey, Stefanie S

    2016-12-20

    Treatment of advanced colorectal cancer (CRC) requires multimodal therapeutic approaches and need for monitoring tumor plasticity. Liquid biopsy biomarkers, including CTCs and ctDNA, hold promise for evaluating treatment response in real-time and guiding therapeutic modifications. From 15 patients with advanced CRC undergoing liver metastasectomy with curative intent, we collected 41 blood samples at different time points before and after surgery for CTC isolation and quantification using label-free Vortex technology. For mutational profiling, KRAS, BRAF, and PIK3CA hotspot mutations were analyzed in CTCs and ctDNA from 23 samples, nine matched liver metastases and three primary tumor samples. Mutational patterns were compared. 80% of patient blood samples were positive for CTCs, using a healthy baseline value as threshold (0.4 CTCs/mL), and 81.4% of captured cells were EpCAM+ CTCs. At least one mutation was detected in 78% of our blood samples. Among 23 matched CTC and ctDNA samples, we found a concordance of 78.2% for KRAS, 73.9% for BRAF and 91.3% for PIK3CA mutations. In several cases, CTCs exhibited a mutation that was not detected in ctDNA, and vice versa. Complementary assessment of both CTCs and ctDNA appears advantageous to assess dynamic tumor profiles.

  16. Patient-specific radiation dose and cancer risk estimation in CT: Part II. Application to patients

    PubMed Central

    Li, Xiang; Samei, Ehsan; Segars, W. Paul; Sturgeon, Gregory M.; Colsher, James G.; Toncheva, Greta; Yoshizumi, Terry T.; Frush, Donald P.

    2011-01-01

    Purpose: Current methods for estimating and reporting radiation dose from CT examinations are largely patient-generic; the body size and hence dose variation from patient to patient is not reflected. Furthermore, the current protocol designs rely on dose as a surrogate for the risk of cancer incidence, neglecting the strong dependence of risk on age and gender. The purpose of this study was to develop a method for estimating patient-specific radiation dose and cancer risk from CT examinations. Methods: The study included two patients (a 5-week-old female patient and a 12-year-old male patient), who underwent 64-slice CT examinations (LightSpeed VCT, GE Healthcare) of the chest, abdomen, and pelvis at our institution in 2006. For each patient, a nonuniform rational B-spine (NURBS) based full-body computer model was created based on the patient’s clinical CT data. Large organs and structures inside the image volume were individually segmented and modeled. Other organs were created by transforming an existing adult male or female full-body computer model (developed from visible human data) to match the framework defined by the segmented organs, referencing the organ volume and anthropometry data in ICRP Publication 89. A Monte Carlo program previously developed and validated for dose simulation on the LightSpeed VCT scanner was used to estimate patient-specific organ dose, from which effective dose and risks of cancer incidence were derived. Patient-specific organ dose and effective dose were compared with patient-generic CT dose quantities in current clinical use: the volume-weighted CT dose index (CTDIvol) and the effective dose derived from the dose-length product (DLP). Results: The effective dose for the CT examination of the newborn patient (5.7 mSv) was higher but comparable to that for the CT examination of the teenager patient (4.9 mSv) due to the size-based clinical CT protocols at our institution, which employ lower scan techniques for smaller patients. However, the overall risk of cancer incidence attributable to the CT examination was much higher for the newborn (2.4 in 1000) than for the teenager (0.7 in 1000). For the two pediatric-aged patients in our study, CTDIvol underestimated dose to large organs in the scan coverage by 30%–48%. The effective dose derived from DLP using published conversion coefficients differed from that calculated using patient-specific organ dose values by −57% to 13%, when the tissue weighting factors of ICRP 60 were used, and by −63% to 28%, when the tissue weighting factors of ICRP 103 were used. Conclusions: It is possible to estimate patient-specific radiation dose and cancer risk from CT examinations by combining a validated Monte Carlo program with patient-specific anatomical models that are derived from the patients’ clinical CT data and supplemented by transformed models of reference adults. With the construction of a large library of patient-specific computer models encompassing patients of all ages and weight percentiles, dose and risk can be estimated for any patient prior to or after a CT examination. Such information may aid in decisions for image utilization and can further guide the design and optimization of CT technologies and scan protocols. PMID:21361209

  17. Patient-specific radiation dose and cancer risk estimation in CT: Part II. Application to patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li Xiang; Samei, Ehsan; Segars, W. Paul

    2011-01-15

    Purpose: Current methods for estimating and reporting radiation dose from CT examinations are largely patient-generic; the body size and hence dose variation from patient to patient is not reflected. Furthermore, the current protocol designs rely on dose as a surrogate for the risk of cancer incidence, neglecting the strong dependence of risk on age and gender. The purpose of this study was to develop a method for estimating patient-specific radiation dose and cancer risk from CT examinations. Methods: The study included two patients (a 5-week-old female patient and a 12-year-old male patient), who underwent 64-slice CT examinations (LightSpeed VCT, GEmore » Healthcare) of the chest, abdomen, and pelvis at our institution in 2006. For each patient, a nonuniform rational B-spine (NURBS) based full-body computer model was created based on the patient's clinical CT data. Large organs and structures inside the image volume were individually segmented and modeled. Other organs were created by transforming an existing adult male or female full-body computer model (developed from visible human data) to match the framework defined by the segmented organs, referencing the organ volume and anthropometry data in ICRP Publication 89. A Monte Carlo program previously developed and validated for dose simulation on the LightSpeed VCT scanner was used to estimate patient-specific organ dose, from which effective dose and risks of cancer incidence were derived. Patient-specific organ dose and effective dose were compared with patient-generic CT dose quantities in current clinical use: the volume-weighted CT dose index (CTDI{sub vol}) and the effective dose derived from the dose-length product (DLP). Results: The effective dose for the CT examination of the newborn patient (5.7 mSv) was higher but comparable to that for the CT examination of the teenager patient (4.9 mSv) due to the size-based clinical CT protocols at our institution, which employ lower scan techniques for smaller patients. However, the overall risk of cancer incidence attributable to the CT examination was much higher for the newborn (2.4 in 1000) than for the teenager (0.7 in 1000). For the two pediatric-aged patients in our study, CTDI{sub vol} underestimated dose to large organs in the scan coverage by 30%-48%. The effective dose derived from DLP using published conversion coefficients differed from that calculated using patient-specific organ dose values by -57% to 13%, when the tissue weighting factors of ICRP 60 were used, and by -63% to 28%, when the tissue weighting factors of ICRP 103 were used. Conclusions: It is possible to estimate patient-specific radiation dose and cancer risk from CT examinations by combining a validated Monte Carlo program with patient-specific anatomical models that are derived from the patients' clinical CT data and supplemented by transformed models of reference adults. With the construction of a large library of patient-specific computer models encompassing patients of all ages and weight percentiles, dose and risk can be estimated for any patient prior to or after a CT examination. Such information may aid in decisions for image utilization and can further guide the design and optimization of CT technologies and scan protocols.« less

  18. Prevalence of non-cardiovascular findings on CT angiography in children with congenital heart disease.

    PubMed

    Malik, Archana; Hellinger, Jeffrey C; Servaes, Sabah; Schwartz, Mathew C; Keller, Marc S; Epelman, Monica

    2017-03-01

    CT angiography is gaining broader acceptance in the evaluation of children with known or suspected congenital heart disease. These studies include non-cardiovascular structures such as the mediastinum, lung parenchyma and upper abdominal organs. It is important to inspect all these structures for potential abnormalities that might be clinically important and, in some cases, may impact care plans. To determine the prevalence of non-cardiovascular findings in CT angiography of children with congenital heart disease. During 28 months, 300 consecutive children (170 males; mean age: 7.1 years, age range: 6 h-26 years), referred from a tertiary pediatric cardiology center, underwent clinically indicated CT angiography to evaluate known or suspected congenital heart disease. Slightly more than half (n = 169) of the patients were postoperative or post-intervention. Examinations were retrospectively reviewed, and non-cardiovascular findings were recorded and tabulated by organ system, congenital heart disease and operative procedure in conjunction with outcomes from medical charts. Non-cardiovascular findings were identified in 83% (n = 250 / 300) of the studies for a total of 857 findings. In 221 patients (n = 73.7% of 300) a total of 813 non-cardiovascular findings were clinically significant, while in 9.7% (n = 29 / 300) of patients, 5.1% (n = 44 / 857) of the findings were nonsignificant. In 38.3% (n = 115 / 300) of patients with significant non-cardiovascular pathology, the findings were unexpected and directly impacted patient care plans. Commonly involved organs with non-cardiovascular findings were the lungs with 280 non-cardiovascular findings in 176 / 300 (58.7%) of patients, the airway with 139 non-cardiovascular findings in 103 / 300 (34.3%) of patients and the liver with 108 non-cardiovascular findings in 72 / 300 (24.0%) of patients. Syndromic associations were noted in 22% (n = 66 / 300) of the patients. Non-cardiovascular findings are common in children with congenital heart disease who undergo CT angiography. Based upon our study population, if a child with congenital heart disease has a CT angiography, five out of six will have non-cardiovascular findings, while nearly three out of four (73.7%; 221 / 300) will have significant non-cardiovascular findings. Close attention to the non-cardiovascular structures in children with congenital heart disease presenting for a CT angiography is recommended as in nearly 40% of these children, findings were unexpected and directly altered patient care.

  19. Acute Adverse Reactions to Nonionic Iodinated Contrast Media for CT: Prospective Randomized Evaluation of the Effects of Dehydration, Oral Rehydration, and Patient Risk Factors.

    PubMed

    Motosugi, Utaroh; Ichikawa, Tomoaki; Sano, Katsuhiro; Onishi, Hiroshi

    2016-11-01

    The objective of our study was to determine the effects of dehydration and oral rehydration on the incidence of acute adverse reactions to iodinated contrast media administered during abdominal and pelvic CT in outpatients. For our prospective randomized study performed at a single institution, adult outpatients undergoing contrast-enhanced abdominal CT were randomly divided into a rehydration group (n = 2244 patients [1379 men and 865 women]; mean age, 65.2 years; age range, 18-90 years) and a control group (n = 3715 [2112 male patients and 1603 female patients]; mean age, 65.8 years; age range, 17-96 years), which included an age- and sex-matched subgroup (adjusted control group, n = 2244). The rehydration group received an oral rehydration solution (500 mL of liquid in which osmotic pressure is adjusted to enhance gastrointestinal absorption) before abdominal and pelvic CT. Patients were also divided into subclinically dehydrated (n = 997) and hydrated (n = 4962) groups according to their answers to a questionnaire that they completed before the CT examination. The patients were interviewed about contrast-induced adverse reactions before they left the CT room, and the reactions were categorized as allergiclike or physiologic. The incidence of reactions was compared between the rehydration and control groups and between the subclinical dehydration and hydrated groups. The rehydration and control groups were compared with an unpaired t test or a chi-square or Fisher test. The overall incidence of an acute adverse reaction was 4.3% (254/5959); the acute adverse reactions included 136 allergiclike and 118 physiologic reactions. Fourteen allergiclike and nine physiologic reactions were moderate grade, and none was severe. There was no significant difference between the rehydration group and adjusted control group in the overall incidence of adverse reactions (99/2244 [4.4%] vs 100/2244 [4.5%], respectively; p = 0.9422) or between the subclinically dehydrated group and hydrated group in the incidence of allergiclike reactions (25/997 [2.5%] vs 111/4962 [2.2%], p = 0.6062) and physiologic reactions (22/997 [2.2%] vs 96/4962 [1.9%], p = 0.5793). Younger age was a risk factor for both allergiclike and physiologic reactions (p ≤ 0.0019). Dehydration and oral rehydration did not affect the incidence of acute adverse reactions to iodinated contrast material for abdominal and pelvic CT in our randomized prospective trial.

  20. Young patients with suspected uncomplicated renal colic are unlikely to have dangerous alternative diagnoses or need emergent intervention.

    PubMed

    Schoenfeld, Elizabeth M; Poronsky, Kye E; Elia, Tala R; Budhram, Gavin R; Garb, Jane L; Mader, Timothy J

    2015-03-01

    In the United States there is debate regarding the appropriate first test for new-onset renal colic, with non-contrast helical computed tomography (CT) receiving the highest ratings from both Agency for Healthcare Research and Quality and the American Urological Association. This is based not only on its accuracy for the diagnosis of renal colic, but also its ability to diagnose other surgical emergencies, which have been thought to occur in 10-15% of patients with suspected renal colic, based on previous studies. In younger patients, it may be reasonable to attempt to avoid immediate CT if concern for dangerous alternative diagnosis is low, based on the risks of radiation from CTs, and particularly in light of evidence that patients with renal colic have a very high likelihood of having multiple CTs in their lifetimes. The objective is to determine the proportion of patients with a dangerous alternative diagnosis in adult patients age 50 and under presenting with uncomplicated (non-infected) suspected renal colic, and also to determine what proportion of these patients undergo emergent urologic intervention. Retrospective chart review of 12 months of patients age 18-50 presenting with "flank pain," excluding patients with end stage renal disease, urinary tract infection, pregnancy and trauma. Dangerous alternative diagnosis was determined by CT. Two hundred and ninety-one patients met inclusion criteria. One hundred and fifteen patients had renal protocol CTs, and zero alternative emergent or urgent diagnoses were identified (one-sided 95% CI [0-2.7%]). Of the 291 encounters, there were 7 urologic procedures performed upon first admission (2.4%, 95% CI [1.0-4.9%]). The prevalence of kidney stone by final diagnosis was 58.8%. This small sample suggests that in younger patients with uncomplicated renal colic, the benefit of immediate CT for suspected renal colic should be questioned. Further studies are needed to determine which patients benefit from immediate CT for suspected renal colic, and which patients could undergo alternate imaging such as ultrasound.

  1. Prognostic Value of Quantitative Metabolic Metrics on Baseline Pre-Sunitinib FDG PET/CT in Advanced Renal Cell Carcinoma

    PubMed Central

    Minamimoto, Ryogo; Barkhodari, Amir; Harshman, Lauren; Srinivas, Sandy; Quon, Andrew

    2016-01-01

    Purpose The objective of this study was to prospectively evaluate various quantitative metrics on FDG PET/CT for monitoring sunitinib therapy and predicting prognosis in patients with metastatic renal cell cancer (mRCC). Methods Seventeen patients (mean age: 59.0 ± 11.6) prospectively underwent a baseline FDG PET/CT and interim PET/CT after 2 cycles (12 weeks) of sunitinib therapy. We measured the highest maximum standardized uptake value (SUVmax) of all identified lesions (highest SUVmax), sum of SUVmax with maximum six lesions (sum of SUVmax), total lesion glycolysis (TLG) and metabolic tumor volume (MTV) from baseline PET/CT and interim PET/CT, and the % decrease in highest SUVmax of lesion (%Δ highest SUVmax), the % decrease in sum of SUVmax, the % decrease in TLG (%ΔTLG) and the % decrease in MTV (%ΔMTV) between baseline and interim PET/CT, and the imaging results were validated by clinical follow-up at 12 months after completion of therapy for progression free survival (PFS). Results At 12 month follow-up, 6/17 (35.3%) patients achieved PFS, while 11/17 (64.7%) patients were deemed to have progression of disease or recurrence within the previous 12 months. At baseline, PET/CT demonstrated metabolically active cancer in all cases. Using baseline PET/CT alone, all of the quantitative imaging metrics were predictive of PFS. Using interim PET/CT, the %Δ highest SUVmax, %Δ sum of SUVmax, and %ΔTLG were also predictive of PFS. Otherwise, interim PET/CT showed no significant difference between the two survival groups regardless of the quantitative metric utilized including MTV and TLG. Conclusions Quantitative metabolic measurements on baseline PET/CT appears to be predictive of PFS at 12 months post-therapy in patients scheduled to undergo sunitinib therapy for mRCC. Change between baseline and interim PET/CT also appeared to have prognostic value but otherwise interim PET/CT after 12 weeks of sunitinib did not appear to be predictive of PFS. PMID:27123976

  2. Improvements in Pneumatosis Cystoides Intestinalis and Hepatic Portal Venous Gas with Conservative Therapy in a Patient on Maintenance Dialysis.

    PubMed

    Torigoe, Kenta; Arai, Hideyuki; Yamashita, Ayuko; Muraya, Yoshiaki; Obata, Yoko; Nishino, Tomoya

    2016-01-01

    A 77-year-old man on maintenance dialysis developed hypotension, nausea and abdominal pain one hour after beginning to undergo hemodialysis. Abdominal computed tomography (CT) showed gas shadows in the intrahepatic portal vein and the small intestinal wall, but no signs indicating intestinal necrosis. Three days later, the gas shadows on abdominal CT disappeared by conservative therapy. In cases with both pneumatosis cystoides intestinalis and hepatic portal venous gas, intestinal necrosis should therefore be suspected and surgical therapy should also be considered, particularly in hemodialysis patients with a risk of intestinal ischemia. However, conservative therapy may be an option in cases with no intestinal necrosis.

  3. Pulmonary atelectasis: a frequent alternative diagnosis in patients undergoing CT-PA for suspected pulmonary embolism.

    PubMed

    Tsai, Kun-Lin; Gupta, Ekta; Haramati, Linda B

    2004-04-01

    The purpose of the study was to evaluate the prevalence of atelectasis as an alternative diagnosis in patients who underwent computed tomographic pulmonary angiography (CT-PA) for suspected pulmonary embolism (PE), and to contrast the pathophysiology of pulmonary atelectasis and PE, both of which are associated with dyspnea and hypoxemia. We retrospectively identified 144 consecutive emergency department patients (n=49) and inpatients (n=95) admitted between July 2001 and June 2002 who were evaluated with CT-PA for suspected PE. There were 98 women and 46 men with a mean age of 58 years (range 27-95 years). Each CT report was reviewed for PE, the words "atelectasis," "collapse," and/or "volume loss," findings known to predispose to atelectasis, and alternative diagnoses. CT scans of those with PE and those with atelectasis were reviewed. Each case was categorized into one of three groups, as follows: group 1, PE; group 2, atelectasis of three or more segments and no PE; group 3, neither PE nor atelectasis. PaO2 was documented, when available (n=115), with PaO2 >100 mmHg recorded as 100 mmHg. Reports for group 3 were reviewed for alternative diagnoses. Thirteen percent of the study population (19/144, group 1) had PE, and two of them had concomitant atelectasis; mean PaO2 was 69 mmHg (range 38-100 mmHg). Nineteen percent of the study population (27/144, group 2) had atelectasis of three or more segments without PE; mean PaO2 was 73 mmHg (range 45-100 mmHg). Sixty-eight percent of the study population (98/144, group 3) had neither PE nor atelectasis; mean PaO2 was 79 mmHg (range 36-100 mmHg). There was a significant difference in the PaO2 between groups 1 and 3 (Student's t-test), with group 2 intermediate. Seventy percent of group 2 (19/27) had at least one finding predisposing to atelectasis: central bronchial abnormality (n=6), moderate or larger pleural effusion (n=11), pleural mass, pneumothorax, elevated hemidiaphragm, and severe kyphosis (the last four all n=1 each), versus 16% (3/19) of group 1 ( P<0.05). Sixty-three percent of group 3 (62/98) had one or more alternative diagnoses on CT that explained the patient's symptoms as follows: pneumonia (28%, 27/98), other lung disease (18%, 18/98), congestive heart failure (13%, 13/98), and malignancy (13%, 13/98). Pulmonary atelectasis was common in patients undergoing CT-PA for suspected PE, equaling pneumonia as the most common alternative diagnosis. Most patients with atelectasis had predisposing findings on CT. Pulmonary atelectasis and PE cause similar symptoms by different mechanisms of ventilation-perfusion mismatch.

  4. Volumetric gain of the human pancreas after left partial pancreatic resection: A CT-scan based retrospective study.

    PubMed

    Phillip, Veit; Zahel, Tina; Danninger, Assiye; Erkan, Mert; Dobritz, Martin; Steiner, Jörg M; Kleeff, Jörg; Schmid, Roland M; Algül, Hana

    2015-01-01

    Regeneration of the pancreas has been well characterized in animal models. However, there are conflicting data on the regenerative capacity of the human pancreas. The aim of the present study was to assess the regenerative capacity of the human pancreas. In a retrospective study, data from patients undergoing left partial pancreatic resection at a single center were eligible for inclusion (n = 185). Volumetry was performed based on 5 mm CT-scans acquired through a 256-slice CT-scanner using a semi-automated software. Data from 24 patients (15 males/9 females) were included. Mean ± SD age was 68 ± 11 years (range, 40-85 years). Median time between surgery and the 1st postoperative CT was 9 days (range, 0-27 days; IQR, 7-13), 55 days (range, 21-141 days; IQR, 34-105) until the 2nd CT, and 191 days (range, 62-1902; IQR, 156-347) until the 3rd CT. The pancreatic volumes differed significantly between the first and the second postoperative CT scans (median volume 25.6 mL and 30.6 mL, respectively; p = 0.008) and had significantly increased further by the 3rd CT scan (median volume 37.9 mL; p = 0.001 for comparison with 1st CT scan and p = 0.003 for comparison with 2nd CT scan). The human pancreas shows a measurable and considerable potential of volumetric gain after partial resection. Multidetector-CT based semi-automated volume analysis is a feasible method for follow-up of the volume of the remaining pancreatic parenchyma after partial pancreatectomy. Effects on exocrine and endocrine pancreatic function have to be evaluated in a prospective manner. Copyright © 2015 IAP and EPC. Published by Elsevier B.V. All rights reserved.

  5. Early PET/CT scan is more effective than RECIST in predicting outcome of patients with liver metastases from colorectal cancer treated with preoperative chemotherapy plus bevacizumab.

    PubMed

    Lastoria, Secondo; Piccirillo, Maria Carmela; Caracò, Corradina; Nasti, Guglielmo; Aloj, Luigi; Arrichiello, Cecilia; de Lutio di Castelguidone, Elisabetta; Tatangelo, Fabiana; Ottaiano, Alessandro; Iaffaioli, Rosario Vincenzo; Izzo, Francesco; Romano, Giovanni; Giordano, Pasqualina; Signoriello, Simona; Gallo, Ciro; Perrone, Francesco

    2013-12-01

    Markers predictive of treatment effect might be useful to improve the treatment of patients with metastatic solid tumors. Particularly, early changes in tumor metabolism measured by PET/CT with (18)F-FDG could predict the efficacy of treatment better than standard dimensional Response Evaluation Criteria In Solid Tumors (RECIST) response. We performed PET/CT evaluation before and after 1 cycle of treatment in patients with resectable liver metastases from colorectal cancer, within a phase 2 trial of preoperative FOLFIRI plus bevacizumab. For each lesion, the maximum standardized uptake value (SUV) and the total lesion glycolysis (TLG) were determined. On the basis of previous studies, a ≤ -50% change from baseline was used as a threshold for significant metabolic response for maximum SUV and, exploratively, for TLG. Standard RECIST response was assessed with CT after 3 mo of treatment. Pathologic response was assessed in patients undergoing resection. The association between metabolic and CT/RECIST and pathologic response was tested with the McNemar test; the ability to predict progression-free survival (PFS) and overall survival (OS) was tested with the Log-rank test and a multivariable Cox model. Thirty-three patients were analyzed. After treatment, there was a notable decrease of all the parameters measured by PET/CT. Early metabolic PET/CT response (either SUV- or TLG-based) had a stronger, independent and statistically significant predictive value for PFS and OS than both CT/RECIST and pathologic response at multivariate analysis, although with different degrees of statistical significance. The predictive value of CT/RECIST response was not significant at multivariate analysis. PET/CT response was significantly predictive of long-term outcomes during preoperative treatment of patients with liver metastases from colorectal cancer, and its predictive ability was higher than that of CT/RECIST response after 3 mo of treatment. Such findings need to be confirmed by larger prospective trials.

  6. Comparison of CT and MRI in patients with tibial plateau fracture: can CT findings predict ligament tear or meniscal injury?

    PubMed

    Mui, Leonora W; Engelsohn, Eliyahu; Umans, Hilary

    2007-02-01

    (1) To determine the accuracy of computed tomography (CT) in the evaluation of ligament tear and avulsion in patients with tibial plateau fracture. (2) To evaluate whether the presence or severity of fracture gap and articular depression can predict meniscal injury. A fellowship-trained musculoskeletal radiologist retrospectively reviewed knee CT and MRI examinations of 41 consecutive patients presenting to a level 1 trauma center with tibial plateau fractures. Fracture gap, articular depression, ligament tear and footprint avulsions were assessed on CT examinations. The MRI studies were examined for osseous and soft tissue injuries, including meniscal tear, meniscal displacement, ligament tear, and ligament avulsion. CT demonstrated torn ligaments with 80% sensitivity and 98% specificity. Only 2% of ligaments deemed intact on careful CT evaluation had partial or complete tears on MRI. Although the degree of fracture gap and articular depression was significantly greater in patients with meniscal injury compared with those without meniscal injury, ROC analysis demonstrated no clear threshold for gap or depression that yielded a combination of high sensitivity and specificity. In the acute setting, CT offers high sensitivity and specificity for depicting osseous avulsions, as well as high negative predictive value for excluding ligament injury. However, MRI remains necessary for the preoperative detection of meniscal injury.

  7. Effects of a radiation dose reduction strategy for computed tomography in severely injured trauma patients in the emergency department: an observational study.

    PubMed

    Kim, Soo Hyun; Jung, Seung Eun; Oh, Sang Hoon; Park, Kyu Nam; Youn, Chun Song

    2011-11-03

    Severely injured trauma patients are exposed to clinically significant radiation doses from computed tomography (CT) imaging in the emergency department. Moreover, this radiation exposure is associated with an increased risk of cancer. The purpose of this study was to determine some effects of a radiation dose reduction strategy for CT in severely injured trauma patients in the emergency department. We implemented the radiation dose reduction strategy in May 2009. A prospective observational study design was used to collect data from patients who met the inclusion criteria during this one year study (intervention group) from May 2009 to April 2010. The prospective data were compared with data collected retrospectively for one year prior to the implementation of the radiation dose reduction strategy (control group). By comparison of the cumulative effective dose and the number of CT examinations in the two groups, we evaluated effects of a radiation dose reduction strategy. All the patients met the institutional adult trauma team activation criteria. The radiation doses calculated by the CT scanner were converted to effective doses by multiplication by a conversion coefficient. A total of 118 patients were included in this study. Among them, 33 were admitted before May 2009 (control group), and 85 were admitted after May 2009 (intervention group). There were no significant differences between the two groups regarding baseline characteristics, such as injury severity and mortality. Additionally, there was no difference between the two groups in the mean number of total CT examinations per patient (4.8 vs. 4.5, respectively; p = 0.227). However, the mean effective dose of the total CT examinations per patient significantly decreased from 78.71 mSv to 29.50 mSv (p < 0.001). The radiation dose reduction strategy for CT in severely injured trauma patients effectively decreased the cumulative effective dose of the total CT examinations in the emergency department. But not effectively decreased the number of CT examinations.

  8. Evaluation of the robustness of the preprocessing technique improving reversible compressibility of CT images: Tested on various CT examinations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jeon, Chang Ho; Kim, Bohyoung; Gu, Bon Seung

    2013-10-15

    Purpose: To modify the preprocessing technique, which was previously proposed, improving compressibility of computed tomography (CT) images to cover the diversity of three dimensional configurations of different body parts and to evaluate the robustness of the technique in terms of segmentation correctness and increase in reversible compression ratio (CR) for various CT examinations.Methods: This study had institutional review board approval with waiver of informed patient consent. A preprocessing technique was previously proposed to improve the compressibility of CT images by replacing pixel values outside the body region with a constant value resulting in maximizing data redundancy. Since the technique wasmore » developed aiming at only chest CT images, the authors modified the segmentation method to cover the diversity of three dimensional configurations of different body parts. The modified version was evaluated as follows. In randomly selected 368 CT examinations (352 787 images), each image was preprocessed by using the modified preprocessing technique. Radiologists visually confirmed whether the segmented region covers the body region or not. The images with and without the preprocessing were reversibly compressed using Joint Photographic Experts Group (JPEG), JPEG2000 two-dimensional (2D), and JPEG2000 three-dimensional (3D) compressions. The percentage increase in CR per examination (CR{sub I}) was measured.Results: The rate of correct segmentation was 100.0% (95% CI: 99.9%, 100.0%) for all the examinations. The median of CR{sub I} were 26.1% (95% CI: 24.9%, 27.1%), 40.2% (38.5%, 41.1%), and 34.5% (32.7%, 36.2%) in JPEG, JPEG2000 2D, and JPEG2000 3D, respectively.Conclusions: In various CT examinations, the modified preprocessing technique can increase in the CR by 25% or more without concerning about degradation of diagnostic information.« less

  9. Sci—Thur PM: Imaging — 06: Canada's National Computed Tomography (CT) Survey

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wardlaw, GM; Martel, N; Blackler, W

    2014-08-15

    The value of computed tomography (CT) in medical imaging is reflected in its' increased use and availability since the early 1990's; however, given CT's relatively larger exposures (vs. planar x-ray) greater care must be taken to ensure that CT procedures are optimised in terms of providing the smallest dose possible while maintaining sufficient diagnostic image quality. The development of CT Diagnostic Reference Levels (DRLs) supports this process. DRLs have been suggested/supported by international/national bodies since the early 1990's and widely adopted elsewhere, but not on a national basis in Canada. Essentially, CT DRLs provide guidance on what is considered goodmore » practice for common CT exams, but require a representative sample of CT examination data to make any recommendations. Canada's National CT Survey project, in collaboration with provincial/territorial authorities, has collected a large national sample of CT practice data for 7 common examinations (with associated clinical indications) of both adult and pediatric patients. Following completion of data entry into a common database, a survey summary report and recommendations will be made on CT DRLs from this data. It is hoped that these can then be used by local regions to promote CT practice optimisation and support any dose reduction initiatives.« less

  10. Radiation doses in examination of lower third molars with computed tomography and conventional radiography.

    PubMed

    Ohman, A; Kull, L; Andersson, J; Flygare, L

    2008-12-01

    To measure organ doses and calculate effective doses for pre-operative radiographic examination of lower third molars with CT and conventional radiography (CR). Measurements of organ doses were made on an anthropomorphic head phantom with lithium fluoride thermoluminescent dosemeters. The dosemeters were placed in regions corresponding to parotid and submandibular glands, mandibular bone, thyroid gland, skin, eye lenses and brain. The organ doses were used for the calculation of effective doses according to proposed International Commission on Radiological Protection 2005 guidelines. For the CT examination, a Siemens Somatom Plus 4 Volume Zoom was used and exposure factors were set to 120 kV and 100 mAs. For conventional radiographs, a Scanora unit was used and panoramic, posteroanterior, stereographic (scanogram) and conventional spiral tomographic views were exposed. The effective doses were 0.25 mSv, 0.060 mSv and 0.093 mSv for CT, CR without conventional tomography and CR with conventional spiral tomography, respectively. The effective dose is low when CT examination with exposure factors optimized for the examination of bone structures is performed. However, the dose is still about four times as high as for CR without tomography. CT should therefore not be a standard method for the examination of lower third molars. In cases where there is a close relationship between the tooth and the inferior alveolar nerve the advantages of true sectional imaging, such as CT, outweighs the higher effective dose and is recommended. Further reduction in the dose is feasible with further optimization of examination protocols and the development of newer techniques.

  11. Crawler Solids Unknown Analysis

    NASA Technical Reports Server (NTRS)

    Frandsen, Athela

    2016-01-01

    Crawler Transporter (CT) #2 has been undergoing refurbishment to carry the Space Launch System (SLS). After returning to normal operation, multiple filters of the gear box lubrication system failed/clogged and went on bypass during a test run to the launch pad. Analysis of the filters was done in large part with polarized light microscopy (PLM) to identify the filter contaminates and the source of origin.

  12. Disappearing renal calculus

    PubMed Central

    Cui, Helen; Thomas, Johanna; Kumar, Sunil

    2013-01-01

    We present a case of a renal calculus treated solely with antibiotics which has not been previously reported in the literature. A man with a 17 mm lower pole renal calculus and concurrent Escherichia coli urine infection was being worked up to undergo percutaneous nephrolithotomy. However, after a course of preoperative antibiotics the stone was no longer seen on retrograde pyelography or CT imaging. PMID:23580676

  13. Routine colonic endoscopic evaluation following resolution of acute diverticulitis: Is it necessary?

    PubMed Central

    Agarwal, Amit K; Karanjawala, Burzeen E; Maykel, Justin A; Johnson, Eric K; Steele, Scott R

    2014-01-01

    Diverticular disease incidence is increasing up to 65% by age 85 in industrialized nations, low fiber diets, and in younger and obese patients. Twenty-five percent of patients with diverticulosis will develop acute diverticulitis. This imposes a significant burden on healthcare systems, resulting in greater than 300000 admissions per year with an estimated annual cost of $3 billion USD. Abdominal computed tomography (CT) is the diagnostic study of choice, with a sensitivity and specificity greater than 95%. Unfortunately, similar CT findings can be present in colonic neoplasia, especially when perforated or inflamed. This prompted professional societies such as the American Society of Colon Rectal Surgeons to recommend patients undergo routine colonoscopy after an episode of acute diverticulitis to rule out malignancy. Yet, the data supporting routine colonoscopy after acute diverticulitis is sparse and based small cohort studies utilizing outdated technology. While any patient with an indication for a colonoscopy should undergo appropriate endoscopic evaluation, in the era of widespread use of high-resolution computed tomography, routine colonic endoscopic evaluation following resolution of acute uncomplicated diverticulitis poses additional costs, comes with inherent risks, and may require further study. In this manuscript, we review the current data related to this recommendation. PMID:25253951

  14. 3D dosimetry estimation for selective internal radiation therapy (SIRT) using SPECT/CT images: a phantom study

    NASA Astrophysics Data System (ADS)

    Debebe, Senait A.; Franquiz, Juan; McGoron, Anthony J.

    2015-03-01

    Selective Internal Radiation Therapy (SIRT) is a common way to treat liver cancer that cannot be treated surgically. SIRT involves administration of Yttrium - 90 (90Y) microspheres via the hepatic artery after a diagnostic procedure using 99mTechnetium (Tc)-macroaggregated albumin (MAA) to detect extrahepatic shunting to the lung or the gastrointestinal tract. Accurate quantification of radionuclide administered to patients and radiation dose absorbed by different organs is of importance in SIRT. Accurate dosimetry for SIRT allows optimization of dose delivery to the target tumor and may allow for the ability to assess the efficacy of the treatment. In this study, we proposed a method that can efficiently estimate radiation absorbed dose from 90Y bremsstrahlung SPECT/CT images of liver and the surrounding organs. Bremsstrahlung radiation from 90Y was simulated using the Compton window of 99mTc (78keV at 57%). 99mTc images acquired at the photopeak energy window were used as a standard to examine the accuracy of dosimetry prediction by the simulated bremsstrahlung images. A Liqui-Phil abdominal phantom with liver, stomach and two tumor inserts was imaged using a Philips SPECT/CT scanner. The Dose Point Kernel convolution method was used to find the radiation absorbed dose at a voxel level for a three dimensional dose distribution. This method will allow for a complete estimate of the distribution of radiation absorbed dose by tumors, liver, stomach and other surrounding organs at the voxel level. The method provides a quantitative predictive method for SIRT treatment outcome and administered dose response for patients who undergo the treatment.

  15. Inverse association between brown adipose tissue activation and white adipose tissue accumulation in successfully treated pediatric malignancy1234

    PubMed Central

    Chalfant, James S; Smith, Michelle L; Hu, Houchun H; Dorey, Fred J; Goodarzian, Fariba; Fu, Cecilia H

    2012-01-01

    Background: Although the accumulation of white adipose tissue (WAT) is a risk factor for disease, brown adipose tissue (BAT) has been suggested to have a protective role against obesity. Objective: We studied whether changes in BAT were related to changes in the amounts of subcutaneous adipose tissue (SAT) and visceral adipose tissue (VAT) in children treated for malignancy. Design: We examined the effect of BAT activity on weight, SAT, and VAT in 32 pediatric patients with cancer whose positron emission tomography–computed tomography (PET-CT) scans at diagnosis showed no BAT activity. Changes in weight, SAT, and VAT from diagnosis to remission for children with metabolically active BAT at disease-free follow-up (BAT+) were compared with those in children without visualized BAT when free of disease (BAT−). Results: Follow-up PET-CT studies (4.7 ± 2.4 mo later) after successful treatment of the cancer showed BAT+ in 19 patients but no active BAT (BAT−) in 13 patients. BAT+ patients, in comparison with BAT− patients, gained significantly less weight (3.3 ± 6.6% compared with 11.0 ± 11.6%; P = 0.02) and had significantly less SAT (18.2 ± 26.5% compared with 67.4 ± 71.7%; P = 0.01) and VAT (22.6 ± 33.5% compared with 131.6 ± 171.8%; P = 0.01) during treatment. Multiple regression analysis indicated that the inverse relations between BAT activation and measures of weight, SAT, and VAT persisted even after age, glucocorticoid treatment, and the season when the PET-CT scans were obtained were accounted for. Conclusion: The activation of BAT in pediatric patients undergoing treatment of malignancy is associated with significantly less adipose accumulation. This trial was registered at clinicaltrials.gov as NCT01517581. PMID:22456659

  16. Is there a role for neck dissection in T1 oral tongue squamous cell carcinoma? The UCLA experience.

    PubMed

    Peng, Kevin A; Chu, Alan C; Lai, Chi; Grogan, Tristan; Elashoff, David; Abemayor, Elliot; St John, Maie A

    2014-01-01

    We sought to examine prognostic and therapeutic implications, including cost-effectiveness, of elective neck dissection in the management of patients with clinically-determined T1N0 oral tongue carcinoma. A retrospective review of patients with cT1N0 oral tongue squamous cell carcinoma who underwent surgical extirpation of primary tumor, with or without elective neck dissection, at UCLA Medical Center from 1990 to 2009 was performed. Cox proportional hazards regression was used to assess effects of variables on time to first loco-regional recurrence. A healthcare costs analysis of elective neck dissection was performed by querying the SEER-Medicare linked database. Of the 123 patients identified with cT1N0 squamous cell carcinoma of the oral tongue, 88 underwent elective neck dissection at the time of tumor resection while 35 did not. For all patients, disease-free survival at 3, 5, and 10 years was 93%, 82%, and 79%. Of the 88 patients undergoing elective neck dissection, 20 (23%) demonstrated occult metastatic disease. Male gender, tumor size, perineural invasion, and occult metastatic disease were individually associated with higher rates of loco-regional recurrence. There was no significant difference in loco-regional recurrence between those who underwent elective neck dissection and those who did not (HR=0.76, p=0.52). On cost analysis, neck dissection was not associated with any significant difference in Medicare payments. The high rate of occult metastasis (23%) following elective neck dissection, which did not confer additional healthcare costs, leads to the recommendation of elective neck dissection in patients with cT1N0 oral tongue squamous cell carcinoma. Copyright © 2014 Elsevier Inc. All rights reserved.

  17. Nipple-Sparing Mastectomy is Not Associated with a Delay of Adjuvant Treatment.

    PubMed

    Albright, Emily L; Schroeder, Mary C; Foster, Kendra; Sugg, Sonia L; Erdahl, Lillian M; Weigel, Ronald J; Lizarraga, Ingrid M

    2018-07-01

    High-volume single-institution studies support the oncologic safety of nipple sparing mastectomy (NSM). Concerns remain regarding the increased potential for complications, recurrence, and delays to subsequent adjuvant therapy. A national database was used to examine treatment and outcomes for NSM patients. Women undergoing unilateral NSM or skin sparing mastectomy (SSM) for stage 0-4 breast cancer from 2004 to 2013 were identified from the National Cancer Database. Demographic and oncologic characteristics, short-term outcomes and time to local and systemic treatment were compared. NSM was performed on 8173 patients: 8.7% were node positive, and for stage 1-4 disease, 10.6% were triple negative (TN) and 15.3% were HER2-positive. NSM patients were less likely than SSM patients to receive chemotherapy [CT] (37.4 vs. 43.4%) or radiation [PMRT] (15.6 vs. 16.9%), and were also more likely to present with clinically early-stage disease. NSM patients with high-risk features were more likely to receive CT in the neoadjuvant [NCT] than adjuvant setting [AC] (OR 3.76, 1.81, and 1.99 for clinical N2/3, TN, and HER2-positive disease, all p < 0.001). On multivariate analysis, NSM patients had a higher rate of pathologic complete response [pCR] (OR 1.41, p < 0.001). Readmission rate, positive margin rate and time to CT, PMRT or hormonal therapy were not increased for NSM compared to SSM patients. Over one third of NSM patients received chemotherapy and/or radiation. NSM patients with high-risk features were more likely to receive NAC and obtain a pCR. NSM patients did not experience worse outcomes or delayed adjuvant therapy compared to SSM.

  18. Pleural effusion biomarkers and computed tomography findings in diagnosing malignant pleural mesothelioma: A retrospective study in a single center.

    PubMed

    Otoshi, Takehiro; Kataoka, Yuki; Ikegaki, Shunkichi; Saito, Emiko; Matsumoto, Hirotaka; Kaku, Sawako; Shimada, Masatoshi; Hirabayashi, Masataka

    2017-01-01

    In this study, we aimed to examine the clinical value of the pleural effusion (PE) biomarkers, soluble mesothelin-related peptide (SMRP), cytokeratin 19 fragment (CYFRA 21-1) and carcinoembryonic antigen (CEA), and the utility of combining chest computed tomography (CT) findings with these biomarkers, in diagnosing malignant pleural mesothelioma (MPM). We conducted a retrospective cohort study in a single center. Consecutive patients with undiagnosed pleural effusions who underwent PE analysis between September 2014 and August 2016 were reviewed. This study included 240 patients (32 with MPM and 208 non-MPM). SMRP and the CYFRA 21-1/CEA ratio had a sensitivity and specificity for diagnosing MPM of 56.3% and 86.5%, and 87.5% and 74.0%, respectively. Using receiver operating characteristics (ROC) curve analysis of the ability of these markers to distinguish MPM from all other PE causes, the area under the ROC curve (AUC) for SMRP and the CYFRA 21-1/CEA ratio was 0.804 and 0.874, respectively. The sensitivity and specificity of SMRP combined with the CYFRA 21-1/CEA ratio were 93.8% and 64.9%, respectively. The sensitivity of the combination of SMRP, the CYFRA 21-1/CEA ratio, and the presence of Leung's criteria (a chest CT finding that is suggestive of malignant pleural disease) was 93.8%. In conclusion, the combined PE biomarkers had a high sensitivity for diagnosing MPM, although the addition of chest CT findings did not improve the sensitivity of SMRP combined with the CYFRA 21-1/CEA ratio. Combination of these biomarkers helped to rule out MPM effectively among patients at high risk of suffering MPM and would be valuable especially for old frail patients who have difficulty in undergoing invasive procedures such as thoracoscopy.

  19. Individualized threshold for tumor segmentation in 18F-FDG PET/CT imaging: The key for response evaluation of neoadjuvant chemoradiation therapy in patients with rectal cancer?

    PubMed

    Fagundes, Theara C; Mafra, Arnoldo; Silva, Rodrigo G; Castro, Ana C G; Silva, Luciana C; Aguiar, Priscilla T; Silva, Josiane A; P Junior, Eduardo; Machado, Alexei M; Mamede, Marcelo

    2018-02-01

    The standard treatment for locally advanced rectal cancer (RC) consists of neoadjuvant chemoradiation followed by radical surgery. Regardless the extensive use of SUVmax in 18F-FDG PET tumor uptake as representation of tumor glycolytic consumption, there is a trend to apply metabolic volume instead. Thus, the aim of the present study was to evaluate a noninvasive method for tumor segmentation using the 18F-FDG PET imaging in order to predict response to neoadjuvant chemoradiation therapy in patients with rectal cancer. The sample consisted of stage II and III rectal cancer patients undergoing 18F-FDG PET/CT examination before and eight weeks after neoadjuvant therapy. An individualized tumor segmentation methodology was applied to generate tumor volumes (SUV2SD) and compare with standard SUVmax and fixed threshold (SUV40%, SUV50% and SUV60%) pre- and post-therapy. Therapeutic response was assessed in the resected specimens using Dworak's protocol recommendations. Several variables were generated and compared with the histopathological results. Seventeen (17) patients were included and analyzed. Significant differences were observed between responders (Dworak 3 and 4) and non-responders for SUVmax-2 (p<0.01), SUV2SD-2 (p<0.05), SUV40%-2 (p<0.05), SUV50%-2 (p<0.05) and SUV60%-2 (p<0.05). ROC analyses showed significant areas under the curve (p<0.01) for the proposed methodology with sensitivity and specificity varying from 60% to 83% and 73% to 82%, respectively. The present study confirmed the predictive power of the variables using a noninvasive individualized methodology for tumor segmentation based on 18F-FDG PET/CT imaging for response evaluation in patients with rectal cancer after neoadjuvant chemoradiation therapy.

  20. Feasibility and radiation dose of high-pitch acquisition protocols in patients undergoing dual-source cardiac CT.

    PubMed

    Sommer, Wieland H; Albrecht, Edda; Bamberg, Fabian; Schenzle, Jan C; Johnson, Thorsten R; Neumaier, Klement; Reiser, Maximilian F; Nikolaou, Konstatin

    2010-12-01

    The objective of this study was to compare image quality and radiation dose between high-pitch and established retrospectively and prospectively gated cardiac CT protocols using an Alderson-Rando phantom and a set of patients. An anthropomorphic Alderson-Rando phantom equipped with thermoluminiscent detectors and a set of clinical patients underwent the following cardiac CT protocols: high-pitch acquisition (pitch 3.4), prospectively triggered acquisition, and retrospectively gated acquisition (pitch 0.2). For patients with sinus rhythm below 65 beats per minute (bpm), high-pitch protocol was used, whereas for patients in sinus rhythm between 65 and 100 bpm, prospective triggering was used. Patients with irregular heart rates or heart rates of ≥ 100 bpm, were examined using retrospectively gated acquisition. Evaluability of coronary artery segments was determined, and effective radiation dose was derived from the phantom study. In the phantom study, the effective radiation dose as determined with thermoluminescent detector (TLD) measurements was lowest in the high-pitch acquisition (1.21, 3.12, and 11.81 mSv, for the high-pitch, the prospectively triggered, and the retrospectively gated acquisition, respectively). There was a significant difference with respect to the percentage of motion-free coronary artery segments (99%, 87%, and 92% for high-pitch, prospectively triggered, and retrospectively gated, respectively (p < 0.001), whereas image noise was lowest for the high-pitch protocol (p < 0.05). High-pitch scans have the potential to reduce radiation dose up to 61.2% and 89.8% compared with prospectively triggered and retrospectively gated scans. High-pitch protocols lead to excellent image quality when used in patients with stable heart rates below 65 bpm.

  1. CT detection of occult pneumothorax in head trauma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tocino, I.M.; Miller, M.H.; Frederick, P.R.

    1984-11-01

    A prospective evaluation for occult pneumothorax was performed in 25 consecutive patients with serious head trauma by combining a limited chest CT examination with the emergency head CT examination. Of 21 pneuomothoraces present in 15 patients, 11 (52%) were found only by chest CT and were not identified clinically or by supine chest radiograph. Because of pending therapeutic measures, chest tubes were placed in nine of the 11 occult pneumothoraces, regardless of the volume. Chest CT proved itself as the most sensitive method for detection of occult pneumothorax, permitting early chest tube placement to prevent transition to a tension pneumothoraxmore » during subsequent mechanical ventilation or emergency surgery under general anesthesia.« less

  2. Comparative effectiveness of 18F-FDG PET-CT and contrast-enhanced CT in the diagnosis of suspected large-vessel vasculitis.

    PubMed

    Vaidyanathan, Sriram; Chattopadhyay, Arpita; Mackie, Sarah L; Scarsbrook, Andrew

    2018-06-21

    Large-vessel vasculitis (LVV) is a serious illness with potentially life-threatening consequences. 18 F-FDG PET-CT has emerged as a valuable diagnostic tool in suspected LVV, combining the strengths of functional and structural imaging. This study aimed to compare the accuracy of FDG PET-CT and contrast-enhanced CT (CECT) in the evaluation of patients with LVV. A retrospective database review for LVV patients undergoing CECT and PET-CT between 2011 to 2016 yielded demographics, scan interval and vasculitis type. Qualitative and quantitative PET-CT analyses included aorta: liver FDG uptake, bespoke FDG uptake distribution scores and vascular maximum standardized uptake values (SUVmax). Quantitative CECT data were assessed wall thickness and mural/lumen ratio. ROC curves were constructed to evaluate comparative diagnostic accuracy and a correlational analysis was conducted between SUVmax and wall-thickness. 36 adults (17 LVV, 19 controls) with a mean age (range) 63 (38-89) years, of which 17 (47%) were males were included. Time interval between CT and PET was mean (standard deviation (SD)) 1.9 (1.2) months. Both SUVmax and wall-thickness demonstrated a significant difference between LVV and controls, with a mean difference (95%confidence interval (CI)) for SUVmax 1.6 (1.1, 2.0) and wall thickness 1.25 (0.68, 1.83) mm, respectively. These two parameters were significantly correlated (p < .0001, R = 0.62). The area under the curve (AUC) (95% CI) for SUVmax was 0.95 (0.88-1.00), and for mural thickening was 0.83 (0.66-0.99). FDG PET-CT demonstrated excellent accuracy whilst CECT mural thickening showed good accuracy in the diagnosis of LVV. Both parameters showed a highly significant correlation. In hospitals without access to FDG PET-CT or in patients unsuitable for PET-CT (e.g., uncontrolled diabetes) CECT offers a viable alternative for the assessment LVV. Advances in knowledge: FDG PET-CT is a highly accurate test for the diagnosis of LVV. Aorta:liver SUVmax ratio is the most specific parameter for LVV. In hospitals without PET-CT or in unsuitable patients e.g. diabetics, CECT is a viable alternative.

  3. Effect of film-based versus filmless operation on the productivity of CT technologists.

    PubMed

    Reiner, B I; Siegel, E L; Hooper, F J; Glasser, D

    1998-05-01

    To determine the relative time required for a technologist to perform a computed tomographic (CT) examination in a "filmless" versus a film-based environment. Time-motion studies were performed in 204 consecutive CT examinations. Images from 96 examinations were electronically transferred to a picture archiving and communication system (PACS) without being printed to film, and 108 were printed to film. The time required to obtain and electronically transfer the images or print the images to film and make the current and previous studies available to the radiologists for interpretation was recorded. The time required for a technologist to complete a CT examination was reduced by 45% with direct image transfer to the PACS compared with the time required in the film-based mode. This reduction was due to the elimination of a number of steps in the filming process, such as the printing at multiple window or level settings. The use of a PACS can result in the elimination of multiple time-intensive tasks for the CT technologist, resulting in a marked reduction in examination time. This reduction can result in increased productivity, and, hence greater cost-effectiveness with filmless operation.

  4. Discrete Event Simulation Models for CT Examination Queuing in West China Hospital.

    PubMed

    Luo, Li; Liu, Hangjiang; Liao, Huchang; Tang, Shijun; Shi, Yingkang; Guo, Huili

    2016-01-01

    In CT examination, the emergency patients (EPs) have highest priorities in the queuing system and thus the general patients (GPs) have to wait for a long time. This leads to a low degree of satisfaction of the whole patients. The aim of this study is to improve the patients' satisfaction by designing new queuing strategies for CT examination. We divide the EPs into urgent type and emergency type and then design two queuing strategies: one is that the urgent patients (UPs) wedge into the GPs' queue with fixed interval (fixed priority model) and the other is that the patients have dynamic priorities for queuing (dynamic priority model). Based on the data from Radiology Information Database (RID) of West China Hospital (WCH), we develop some discrete event simulation models for CT examination according to the designed strategies. We compare the performance of different strategies on the basis of the simulation results. The strategy that patients have dynamic priorities for queuing makes the waiting time of GPs decrease by 13 minutes and the degree of satisfaction increase by 40.6%. We design a more reasonable CT examination queuing strategy to decrease patients' waiting time and increase their satisfaction degrees.

  5. Discrete Event Simulation Models for CT Examination Queuing in West China Hospital

    PubMed Central

    Luo, Li; Tang, Shijun; Shi, Yingkang; Guo, Huili

    2016-01-01

    In CT examination, the emergency patients (EPs) have highest priorities in the queuing system and thus the general patients (GPs) have to wait for a long time. This leads to a low degree of satisfaction of the whole patients. The aim of this study is to improve the patients' satisfaction by designing new queuing strategies for CT examination. We divide the EPs into urgent type and emergency type and then design two queuing strategies: one is that the urgent patients (UPs) wedge into the GPs' queue with fixed interval (fixed priority model) and the other is that the patients have dynamic priorities for queuing (dynamic priority model). Based on the data from Radiology Information Database (RID) of West China Hospital (WCH), we develop some discrete event simulation models for CT examination according to the designed strategies. We compare the performance of different strategies on the basis of the simulation results. The strategy that patients have dynamic priorities for queuing makes the waiting time of GPs decrease by 13 minutes and the degree of satisfaction increase by 40.6%. We design a more reasonable CT examination queuing strategy to decrease patients' waiting time and increase their satisfaction degrees. PMID:27547237

  6. Positive effect of combined exercise training in a model of metabolic syndrome and menopause: autonomic, inflammatory, and oxidative stress evaluations.

    PubMed

    Conti, Filipe Fernandes; Brito, Janaina de Oliveira; Bernardes, Nathalia; Dias, Danielle da Silva; Malfitano, Christiane; Morris, Mariana; Llesuy, Susana Francisca; Irigoyen, Maria-Cláudia; De Angelis, Kátia

    2015-12-15

    It is now well established that after menopause cardiometabolic disorders become more common. Recently, resistance exercise has been recommended as a complement to aerobic (combined training, CT) for the treatment of cardiometabolic diseases. The aim of this study was to evaluate the effects of CT in hypertensive ovariectomized rats undergoing fructose overload in blood pressure variability (BPV), inflammation, and oxidative stress parameters. Female rats were divided into the following groups (n = 8/group): sedentary normotensive Wistar rats (C), and sedentary (FHO) or trained (FHOT) ovariectomized spontaneously hypertensive rats undergoing and fructose overload. CT was performed on a treadmill and ladder adapted to rats in alternate days (8 wk; 40-60% maximal capacity). Arterial pressure (AP) was directly measured. Oxidative stress and inflammation were measured on cardiac and renal tissues. The association of risk factors (hypertension + ovariectomy + fructose) promoted increase in insulin resistance, mean AP (FHO: 174 ± 4 vs. C: 108 ± 1 mmHg), heart rate (FHO: 403 ± 12 vs. C: 352 ± 11 beats/min), BPV, cardiac inflammation (tumor necrosis factor-α-FHO: 65.8 ± 9.9 vs. C: 23.3 ± 4.3 pg/mg protein), and oxidative stress cardiac and renal tissues. However, CT was able to reduce mean AP (FHOT: 158 ± 4 mmHg), heart rate (FHOT: 303 ± 5 beats/min), insulin resistance, and sympathetic modulation. Moreover, the trained rats presented increased nitric oxide bioavailability, reduced tumor necrosis factor-α (FHOT: 33.1 ± 4.9 pg/mg protein), increased IL-10 in cardiac tissue and reduced lipoperoxidation, and increased antioxidant defenses in cardiac and renal tissues. In conclusion, the association of risk factors promoted an additional impairment in metabolic, cardiovascular, autonomic, inflammatory, and oxidative stress parameters and combined exercise training was able to attenuate these dysfunctions. Copyright © 2015 the American Physiological Society.

  7. Usefulness and pitfalls of MAA SPECT/CT in identifying digestive extrahepatic uptake when planning liver radioembolization.

    PubMed

    Lenoir, Laurence; Edeline, Julien; Rolland, Yann; Pracht, Marc; Raoul, Jean-Luc; Ardisson, Valérie; Bourguet, Patrick; Clément, Bruno; Boucher, Eveline; Garin, Etienne

    2012-05-01

    Identifying gastroduodenal uptake of (99m)Tc-macroaggregated albumin (MAA), which is associated with an increased risk of ulcer disease, is a crucial part of the therapeutic management of patients undergoing radioembolization for liver tumours. Given this context, the use of MAA single photon emission computed tomography (SPECT)/CT may be essential, but the procedure has still not been thoroughly evaluated. The aim of this retrospective study was to determine the effectiveness of MAA SPECT/CT in identifying digestive extrahepatic uptake, while determining potential diagnostic pitfalls. Overall, 139 MAA SPECT/CT scans were performed on 103 patients with different hepatic tumour types. Patients were followed up for at least 6 months according to standard requirements. Digestive, or digestive-like, uptake other than free pertechnetate was identified in 5.7% of cases using planar imaging and in 36.6% of cases using SPECT/CT. Uptake sites identified by SPECT/CT included the gastroduodenal region (3.6%), gall bladder (12.2%), portal vein thrombosis (6.5%), hepatic artery (6.5%), coil embolization site (2.1%) as well as falciform artery (5.0%). For 2.1% of explorations, a coregistration error between SPECT and CT imaging could have led to a false diagnosis by erroneously attributing an uptake site to the stomach or gall bladder, when the uptake actually occurred in the liver. SPECT/CT is more efficacious than planar imaging in identifying digestive extrahepatic uptake sites, with extrahepatic uptake observed in one third of scans using the former procedure. However, more than half of the uptake sites in our study were vascular in nature, without therapeutic implications. The risk of coregistration errors must also be kept in mind.

  8. The cost-effectiveness of CT-guided sacroiliac joint injections: a measure of QALY gained.

    PubMed

    Bydon, Mohamad; Macki, Mohamed; De la Garza-Ramos, Rafael; Youssef, Mina; Gokaslan, Ziya L; Meleka, Sherif; Bydon, Ali

    2014-10-01

    The purpose of this study is to estimate the total cost and the quality of life years (QALY) gained for computer tomography (CT)-guided sacroiliac joint (SIJ) injections. The cost per QALY gained for the procedure is the primary end-point of this study. In our 1-year prospective institutional study, we gathered 30 patients undergoing CT-guided SIJ injections for degenerative changes at the SIJ space. Patient-reported outcomes included both the US population-based EQ-5D (EuroQol) index score and the EQ-visual analog scale (VAS). The EQ-5D is based on mobility, self-care, usual activities, pain/discomfort, and anxiety depression. Utility expenditures were based on hospital charges at our institution. All 30 patients had one pre-injection physician visit followed by 43 initial injections (13 bilateral). Each patient underwent one CT scan, and three patients required additional plain films. In the 1 year following the injections, 26 physician visits were documented. Five patients required repeat CT-guided injections. Total 1-year cost for all 30 patients was $34 874·00. Mean decrease in EQ-VAS was 0·60 (P  =  0·187). The mean 1-year gain of 0·58 EQ-5D QALY reached statistical significance (P < 0·001). The cost per QALY gained by CT-guided sacroiliac injections was $2004·29. In one of the first cost analyses of CT-guided sacroiliac injections, we found that the procedure improves pain and activities of daily living. The cost per QALY gained by CT-guided sacroiliac injections falls well below the threshold cost of 1 QALY, suggesting that the procedure is strongly cost-effective.

  9. Total Navigation in Spine Surgery; A Concise Guide to Eliminate Fluoroscopy Using a Portable Intraoperative Computed Tomography 3-Dimensional Navigation System.

    PubMed

    Navarro-Ramirez, Rodrigo; Lang, Gernot; Lian, Xiaofeng; Berlin, Connor; Janssen, Insa; Jada, Ajit; Alimi, Marjan; Härtl, Roger

    2017-04-01

    Portable intraoperative computed tomography (iCT) with integrated 3-dimensional navigation (NAV) offers new opportunities for more precise navigation in spinal surgery, eliminates radiation exposure for the surgical team, and accelerates surgical workflows. We present the concept of "total navigation" using iCT NAV in spinal surgery. Therefore, we propose a step-by-step guideline demonstrating how total navigation can eliminate fluoroscopy with time-efficient workflows integrating iCT NAV into daily practice. A prospective study was conducted on collected data from patients undergoing iCT NAV-guided spine surgery. Number of scans, radiation exposure, and workflow of iCT NAV (e.g., instrumentation, cage placement, localization) were documented. Finally, the accuracy of pedicle screws and time for instrumentation were determined. iCT NAV was successfully performed in 117 cases for various indications and in all regions of the spine. More than half (61%) of cases were performed in a minimally invasive manner. Navigation was used for skin incision, localization of index level, and verification of implant position. iCT NAV was used to evaluate neural decompression achieved in spinal fusion surgeries. Total navigation eliminates fluoroscopy in 75%, thus reducing staff radiation exposure entirely. The average times for iCT NAV setup and pedicle screw insertion were 12.1 and 3.1 minutes, respectively, achieving a pedicle screw accuracy of 99%. Total navigation makes spine surgery safer and more accurate, and it enhances efficient and reproducible workflows. Fluoroscopy and radiation exposure for the surgical staff can be eliminated in the majority of cases. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. CT and 3-T MRI accurately identify T3c disease in colon cancer, which strongly predicts disease-free survival.

    PubMed

    Hunter, C; Siddiqui, M; Georgiou Delisle, T; Blake, H; Jeyadevan, N; Abulafi, M; Swift, I; Toomey, P; Brown, G

    2017-04-01

    To compare the preoperative staging accuracy of computed tomography (CT) and 3-T magnetic resonance imaging (MRI) in colon cancer, and to investigate the prognostic significance of identified risk factors. Fifty-eight patients undergoing primary resection of their colon cancer were prospectively recruited, with 53 patients included for final analysis. Accuracy of CT and MRI were compared for two readers, using postoperative histology as the reference standard. Patients were followed-up for a median of 39 months. Risk factors were compared by modality and reader in terms of metachronous metastases and disease-free survival (DFS), stratified for adjuvant chemotherapy. Accuracy for the identification of T3c+ disease was non-significantly greater on MRI (75% and 79%) than CT (70% and 77%). Differences in the accuracy of MRI and CT for identification of T3+ disease (MRI 75% and 57%, CT 72% and 66%) and N+ disease (MRI 62% and 63%, CT 62% and 56%) were also non-significant. Identification of extramural venous invasion (EMVI+) disease was significantly greater on MRI (75% and 75%) than CT (79% and 54%) for one reader (p=0.029). T3c+ disease at histopathology was the only risk factor that demonstrated a significant difference in rate of metachronous metastases (odds ratio [OR] 8.6, p=0.0044) and DFS stratified for adjuvant therapy (OR=4, p=0.048). T3c or greater disease is the strongest risk factor for predicting DFS in colon cancer, and is accurately identified on imaging. T3c+ disease may therefore be the best imaging entry criteria for trials of neoadjuvant treatment. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  11. Does diagnosis change as a result of repeat renal colic computed tomography scan in patients with a history of kidney stones?

    PubMed

    Goldstone, Adam; Bushnell, Andrew

    2010-03-01

    We sought to determine the incidence of alternative diagnosis in patients with a history of kidney stones who experience recurrent symptoms and undergo repeat computed tomography (CT) imaging at their return to the emergency department (ED). This was a retrospective chart review of ED patients at a tertiary care hospital. Inclusion criteria were all adult ED patients who received a repeat CT for renal colic, after having previously received the diagnosis of obstructive kidney stone confirmed by CT, in our ED. Patients were identified by reviewing the charts of those patients with repeat visits to the ED after January 1, 2004, in which they complained of symptoms suggestive of renal colic and received a CT scan. We determined the frequency of the same diagnosis on repeat CT scan in this population compared with the frequency of alternative diagnosis. Two hundred thirty-one patients met criteria for the study. Fifty-nine percent were male. One hundred eighty-nine (81.8%) patients had no change in diagnosis as a result of a repeat renal colic CT scan. Twenty-seven (11.6%) patients received an alternative diagnosis that did not require urgent intervention, and 15 (6.5%) patients received a diagnosis that did require an urgent intervention. Repeat CT imaging of patients with known nephrolithiasis changed management in a minority of patients (6.5%). Knowing the frequency of alternative diagnosis in this population may help clinicians and patients balance the risks and benefits of repeat renal colic CT scans in patients with a history of kidney stones who return to the ED with similar symptoms. 2010 Elsevier Inc. All rights reserved.

  12. Prevalence and malignancy risk of focal colorectal incidental uptake detected by (18)F-FDG-PET or PET/CT: a meta-analysis.

    PubMed

    Treglia, Giorgio; Taralli, Silvia; Salsano, Marco; Muoio, Barbara; Sadeghi, Ramin; Giovanella, Luca

    2014-06-01

    The aim of the study was to meta-analyze published data about prevalence and malignancy risk of focal colorectal incidentalomas (FCIs) detected by Fluorine-18-Fluorodeoxyglucose positron emission tomography or positron emission tomography/computed tomography ((18)F-FDG-PET or PET/CT). A comprehensive computer literature search of studies published through July 31(st) 2012 regarding FCIs detected by (18)F-FDG-PET or PET/CT was performed. Pooled prevalence of patients with FCIs and risk of malignant or premalignant FCIs after colonoscopy or histopathology verification were calculated. Furthermore, separate calculations for geographic areas were performed. Finally, average standardized uptake values (SUV) in malignant, premalignant and benign FCIs were reported. Thirty-two studies comprising 89,061 patients evaluated by (18)F-FDG-PET or PET/CT were included. The pooled prevalence of FCIs detected by (18)F-FDG-PET or PET/CT was 3.6% (95% confidence interval [95% CI]: 2.6-4.7%). Overall, 1,044 FCIs detected by (18)F-FDG-PET or PET/CT underwent colonoscopy or histopathology evaluation. Pooled risk of malignant or premalignant lesions was 68% (95% CI: 60-75%). Risk of malignant and premalignant FCIs in Asia-Oceania was lower compared to that of Europe and America. A significant overlap in average SUV was found between malignant, premalignant and benign FCIs. FCIs are observed in a not negligible number of patients who undergo (18)F-FDG-PET or PET/CT studies with a high risk of malignant or premalignant lesions. SUV is not reliable as a tool to differentiate between malignant, premalignant and benign FCIs. Further investigation is warranted whenever FCIs are detected by (18)F-FDG-PET or PET/CT.

  13. Prevalence and malignancy risk of focal colorectal incidental uptake detected by 18F-FDG-PET or PET/CT: a meta-analysis

    PubMed Central

    Treglia, Giorgio; Taralli, Silvia; Salsano, Marco; Muoio, Barbara; Sadeghi, Ramin; Giovanella, Luca

    2014-01-01

    Background The aim of the study was to meta-analyze published data about prevalence and malignancy risk of focal colorectal incidentalomas (FCIs) detected by Fluorine-18-Fluorodeoxyglucose positron emission tomography or positron emission tomography/computed tomography (18F-FDG-PET or PET/CT). Methods A comprehensive computer literature search of studies published through July 31st 2012 regarding FCIs detected by 18F-FDG-PET or PET/CT was performed. Pooled prevalence of patients with FCIs and risk of malignant or premalignant FCIs after colonoscopy or histopathology verification were calculated. Furthermore, separate calculations for geographic areas were performed. Finally, average standardized uptake values (SUV) in malignant, premalignant and benign FCIs were reported. Results Thirty-two studies comprising 89,061 patients evaluated by 18F-FDG-PET or PET/CT were included. The pooled prevalence of FCIs detected by 18F-FDG-PET or PET/CT was 3.6% (95% confidence interval [95% CI]: 2.6–4.7%). Overall, 1,044 FCIs detected by 18F-FDG-PET or PET/CT underwent colonoscopy or histopathology evaluation. Pooled risk of malignant or premalignant lesions was 68% (95% CI: 60–75%). Risk of malignant and premalignant FCIs in Asia-Oceania was lower compared to that of Europe and America. A significant overlap in average SUV was found between malignant, premalignant and benign FCIs. Conclusions FCIs are observed in a not negligible number of patients who undergo 18F-FDG-PET or PET/CT studies with a high risk of malignant or premalignant lesions. SUV is not reliable as a tool to differentiate between malignant, premalignant and benign FCIs. Further investigation is warranted whenever FCIs are detected by 18F-FDG-PET or PET/CT. PMID:24991198

  14. Validation of a novel CARTOSEG™ segmentation module software for contrast-enhanced computed tomography-guided radiofrequency ablation in patients with atrial fibrillation.

    PubMed

    Imanli, Hasan; Bhatty, Shaun; Jeudy, Jean; Ghzally, Yousra; Ume, Kiddy; Vunnam, Rama; Itah, Refael; Amit, Mati; Duell, John; See, Vincent; Shorofsky, Stephen; Dickfeld, Timm M

    2017-11-01

    Visualization of left atrial (LA) anatomy using image integration modules has been associated with decreased radiation exposure and improved procedural outcome when used for guidance of pulmonary vein isolation (PVI) in atrial fibrillation (AF) ablation. We evaluated the CARTOSEG™ CT Segmentation Module (Biosense Webster, Inc.) that offers a new CT-specific semiautomatic reconstruction of the atrial endocardium. The CARTOSEG™ CT Segmentation Module software was assessed prospectively in 80 patients undergoing AF ablation. Using preprocedural contrast-enhanced computed tomography (CE-CT), cardiac chambers, coronary sinus (CS), and esophagus were semiautomatically segmented. Segmentation quality was assessed from 1 (poor) to 4 (excellent). The reconstructed structures were registered with the electroanatomic map (EAM). PVI was performed using the registered 3D images. Semiautomatic reconstruction of the heart chambers was successfully performed in all 80 patients with AF. CE-CT DICOM file import, semiautomatic segmentation of cardiac chambers, esophagus, and CS was performed in 185 ± 105, 18 ± 5, 119 ± 47, and 69 ± 19 seconds, respectively. Average segmentation quality was 3.9 ± 0.2, 3.8 ± 0.3, and 3.8 ± 0.2 for LA, esophagus, and CS, respectively. Registration accuracy between the EAM and CE-CT-derived segmentation was 4.2 ± 0.9 mm. Complications consisted of one perforation (1%) which required pericardiocentesis, one increased pericardial effusion treated conservatively (1%), and one early termination of ablation due to thrombus formation on the ablation sheath without TIA/stroke (1%). All targeted PVs (n  =  309) were successfully isolated. The novel CT- CARTOSEG™ CT Segmentation Module enables a rapid and reliable semiautomatic 3D reconstruction of cardiac chambers and adjacent anatomy, which facilitates successful and safe PVI. © 2017 Wiley Periodicals, Inc.

  15. Magnetic Resonance Imaging of Pulmonary Embolism: Diagnostic Accuracy of Unenhanced MR and Influence in Mortality Rates.

    PubMed

    Pasin, Lilian; Zanon, Matheus; Moreira, Jose; Moreira, Ana Luiza; Watte, Guilherme; Marchiori, Edson; Hochhegger, Bruno

    2017-04-01

    We evaluated the diagnostic value for pulmonary embolism (PE) of the True fast imaging with steady-state precession (TrueFISP) MRI, a method that allows the visualization of pulmonary vasculature without breath holding or intravenous contrast. This is a prospective investigation including 93 patients with suspected PE. All patients underwent TrueFISP MRI after undergoing CT pulmonary angiography (CTPA). Two independent readers evaluated each MR study, and consensus was obtained. CTPA results were analysed by a third independent reviewer and these results served as the reference standard. A fourth radiologist was responsible for evaluating if lesions found on MRI for both analysis were the same and if these were the correspondent lesions on the CTPA. Sensitivity, specificity, predictive values and accuracy were calculated. Evidence for death from PE within the 1-year follow-up was also assessed. Two patients could not undergo the real-time MRI and were excluded from the study. PE prevalence was 22%. During the 1-year follow-up period, eight patients died, whereas PE was responsible for 12.5% of cases. Between patients who developed PE, only 5% died due to this condition. There were no differences between MR and CT embolism detection in these subjects. MR sequences had a sensitivity of 85%, specificity was 98.6% and accuracy was 95.6%. Agreement between readers was high (κ= 0.87). Compared with contrast-enhanced CT, unenhanced MR sequences demonstrate good accuracy and no differences in the mortality rates in 1 year were detected.

  16. Variability in the use of neuroimaging techniques for diagnosis and follow-up of stroke patients.

    PubMed

    Valcárcel-Nazco, C; Alonso-Modino, D; Montón-Álvarez, F; Sabatel-Hernández, R; Pastor-Santoveña, M S; Mesa-Blanco, P; López-Fernández, J C; Serrano-Aguilar, P

    2017-04-18

    Imaging diagnosis is essential for treatment planning in stroke patients. However, use of these techniques varies due to uncertainty about their effectiveness. Our purpose was to describe the use of CT and MRI in stroke and transient ischaemic attack (TIA) over 5years in hospitals belonging to the Canary Islands Health Service and analyse interhospital variability based on routinely collected administrative data. We gathered the minimum basic dataset (MBDS) from patients diagnosed with stroke or TIA between 2005 and 2010 in 4hospitals. Patients' age, sex, procedures, secondary diagnoses, and duration of hospital stay were also recorded. We conducted a descriptive analysis of patient characteristics and a bivariate analysis using the t test and the chi square test to detect differences between patients assessed and not assessed with MRI. Logistic regression was used to analyse unequal access to MRI. Our study included 10,487 patients (8,571 with stroke and 1,916 with TIA). The percentage of stroke patients undergoing a CT scan increased from 89.47% in 2005 to 91.50% in 2010. In these patients, use of MRI also increased from 25.41% in 2005 to 36.02% in 2010. Among patients with TIA, use of CT increased from 84.64% to 88.04% and MRI from 32.53% to 39.13%. According to our results, female sex, younger age, and presence of comorbidities increase the likelihood of undergoing MRI. Copyright © 2017 Sociedad Española de Neurología. Publicado por Elsevier España, S.L.U. All rights reserved.

  17. Computed tomography (CT) in the selection of treatment for root-filled maxillary molars with apical periodontitis

    PubMed Central

    Huumonen, Sisko; Molander, Anders; Öhman, Anders; Kvist, Thomas

    2016-01-01

    Objectives: The aims of this study were to evaluate whether the use of CT facilitates agreement among endodontists in selecting treatments for root-filled maxillary molars with apical periodontitis and to assess the efficacy of CT in choosing a treatment for such teeth. Methods: 39 root-filled maxillary molars from 34 patients with suspected apical periodontitis were independently evaluated by 4 endodontists and 1 postgraduate student (decision-makers). Treatment decisions were made based on intra-oral radiographs and a fictive clinical history. After 1–3 months, the same decision-makers repeated the examination of the same teeth but with additional information from a CT examination. Agreement between decision-makers with or without the availability of the CT results was measured with Cohen's kappa coefficient. Differences in selected treatments with or without accessibility to the CT results were plotted for the same endodontists using descriptive statistics. Results: The agreement in assessments among endodontists was slight or fair before the CT results were available (range: 0.081–0.535). No increase was observed after reviewing the CT results (range: 0.116–0.379). After the use of CT, the treatment plan was changed 38–76% of the time by all decision-makers, and the changes affected 57.8% of the cases in the study. Conclusions: The endodontists in this study exhibited a low degree of agreement when choosing a treatment for root-filled maxillary molars with apical periodontitis. A CT examination of the investigated teeth did not result in a significantly higher degree of agreement, and CT frequently contributed to a shift in the selected therapy. PMID:26985980

  18. Single-energy pediatric chest computed tomography with spectral filtration at 100 kVp: effects on radiation parameters and image quality.

    PubMed

    Bodelle, Boris; Fischbach, Constanze; Booz, Christian; Yel, Ibrahim; Frellesen, Claudia; Kaup, Moritz; Beeres, Martin; Vogl, Thomas J; Scholtz, Jan-Erik

    2017-06-01

    Most of the applied radiation dose at CT is in the lower photon energy range, which is of limited diagnostic importance. To investigate image quality and effects on radiation parameters of 100-kVp spectral filtration single-energy chest CT using a tin-filter at third-generation dual-source CT in comparison to standard 100-kVp chest CT. Thirty-three children referred for a non-contrast chest CT performed on a third-generation dual-source CT scanner were examined at 100 kVp with a dedicated tin filter with a tube current-time product resulting in standard protocol dose. We compared resulting images with images from children examined using standard single-source chest CT at 100 kVp. We assessed objective and subjective image quality and compared radiation dose parameters. Radiation dose was comparable for children 5 years old and younger, and it was moderately decreased for older children when using spectral filtration (P=0.006). Effective tube current increased significantly (P=0.0001) with spectral filtration, up to a factor of 10. Signal-to-noise ratio and image noise were similar for both examination techniques (P≥0.06). Subjective image quality showed no significant differences (P≥0.2). Using 100-kVp spectral filtration chest CT in children by means of a tube-based tin-filter on a third-generation dual-source CT scanner increases effective tube current up to a factor of 10 to provide similar image quality at equivalent dose compared to standard single-source CT without spectral filtration.

  19. Preoperative evaluation of renal anatomy and renal masses with helical CT, 3D-CT and 3D-CT angiography.

    PubMed

    Toprak, Uğur; Erdoğan, Aysun; Gülbay, Mutlu; Karademir, Mehmet Alp; Paşaoğlu, Eşref; Akar, Okkeş Emrah

    2005-03-01

    The aim of this prospective study was to determine the efficacy of three-dimensional computed tomography (3D-CT) and three-dimensional computed tomographic angiography (3D-CTA) that were reconstructed by using the axial images of the multiphasic helical CT in the preoperative evaluation of renal masses and demonstration of renal anatomy. Twenty patients that were suspected of having renal masses upon initial physical examination and ultrasonographic evaluation were examined through multiphasic helical CT. Two authors executed CT evaluations. Axial images were first examined and then used to reconstruct 3D-CT and 3D- CTA images. Number, location and size of the renal masses and other findings were noted. Renal vascularization and relationships of the renal masses with the neighboring renal structures were further investigated with 3D-CT and 3D-CTA images. Out of 20 patients, 13 had histopathologically proven renal cell carcinoma. The diagnoses of the remaining seven patients were xanthogranulomatous pyelonephritis, abscess, simple cyst, infected cyst, angiomyolipoma, oncocytoma and arteriovenous fistula. In the renal cell carcinoma group, 3 patients had stage I, 7 patients had stage II, and 3 patients had stage III disease. Sizes of renal cell carcinoma masses were between 23 mm to 60 mm (mean, 36 mm). Vascular invasion was shown in 2 renal cell carcinoma patients. Collecting system invasion was identified in 11 of 13 renal cell patients. These radiologic findings were confirmed with surgical specimens. Three-dimensional CT and 3D-CTA are non-invasive, effective imaging techniques for the preoperative evaluation of renal masses.

  20. Patient doses from CT examinations in Turkey.

    PubMed

    Ataç, Gökçe Kaan; Parmaksız, Aydın; İnal, Tolga; Bulur, Emine; Bulgurlu, Figen; Öncü, Tolga; Gündoğdu, Sadi

    2015-01-01

    We aimed to establish the first diagnostic reference levels (DRLs) for computed tomography (CT) examinations in adult and pediatric patients in Turkey and compare these with international DRLs. CT performance information and examination parameters (for head, chest, high-resolution CT of the chest [HRCT-chest], abdominal, and pelvic protocols) from 1607 hospitals were collected via a survey. Dose length products and effective doses for standard patient sizes were calculated from the reported volume CT dose index (CTDIvol). The median number of protocols reported from the 167 responding hospitals (10% response rate) was 102 across five different age groups. Third quartile CTDIvol values for adult pelvic and all pediatric body protocols were higher than the European Commission standards but were comparable to studies conducted in other countries. The radiation dose indicators for adult patients were similar to those reported in the literature, except for those associated with head protocols. CT protocol optimization is necessary for adult head and pediatric chest, HRCT-chest, abdominal, and pelvic protocols. The findings from this study are recommended for use as national DRLs in Turkey.

  1. Critical Thinking Measurement in ICT

    ERIC Educational Resources Information Center

    Shannon, Li-Jen; Schneider, Solomon; Bennett, Judith F.

    2010-01-01

    This study examined the status of critical thinking (CT) and reasoning skills in information communication and technology (ICT) for 190 college students in a higher education system. It analyzed how the students performed in CT, reasoning, and internet copyright and ethical issues. A CT assessment was designed to analyze the CT and reasoning…

  2. Assessing the role of 18F-FDG PET and 18F-FDG PET/CT in the diagnosis of soft tissue musculoskeletal malignancies – A systematic review and meta-analysis

    PubMed Central

    Etchebehere, Elba C.; Hobbs, Brian P.; R.Milton, Denái; Malawi, Osama; Patel, Shreyaskumar; Benjamin, Robert S.; Macapinlac, Homer A.

    2016-01-01

    Purpose Twelve years ago a meta-analysis evaluated the diagnostic performance of 18F-FDG PET in assessing musculoskeletal soft tissue lesions (MsSTL). Currently, PET/CT has substituted PET imaging however there has not been any published meta-analysis on the use of PET/CT or a comparison of PET/CT with PET in the diagnosis of MsSTL. Therefore, we conducted a meta-analysis to identify the current diagnostic performance of 18F-FDG PET/CT and determine if there is added value when compared to PET. Patients and Methods A systematic review of English articles using MEDLINE PubMed, the Cochrane Library and EMBASE were searched from 1996 to March 2015. Studies exploring the diagnostic accuracy of 18F-FDG PET/CT (or dedicated PET) compared to histopathology in patients with MsSTL undergoing investigation for malignancy were included. Results Our meta-analysis included 14 articles composed of 755 patients with 757 soft tissue lesions. There were 451 (60%) malignant tumors and 306 benign lesions. The 18F-FDG PET/CT (and dedicated PET) mean sensitivity, specificity, accuracy, positive and negative predictive values for diagnosing MsSTL was 0.96 (0.90, 1.00), 0.77 (0.67, 0.86), 0.88 (0.85, 0.91), 0.86 (0.78, 0.94) and 0.91 (0.83, 0.99), respectively. The posterior mean (95% HPD interval) for the AUC was 0.92 (0.88, 0.96). PET/CT had higher specificity, accuracy and positive predictive value when compared to a dedicated PET (0.85, 0.89 and 0.91 vs 0.71, 0.85 and 0.82, respectively). Conclusions 18F-FDG PET/CT and dedicated PET are both highly accurate in the diagnosis of MsSTL. PET/CT is more accurate, specific and has a higher positive predictive value than PET. PMID:26631240

  3. Lymph Node Size on Computed Tomography Images Is a Predictive Indicator for Lymph Node Metastasis in Patients with Colorectal Neuroendocrine Tumors.

    PubMed

    Tanaka, Toshiaki; Nozawa, Hiroaki; Kawai, Kazushige; Hata, Keisuke; Kiyomatsu, Tomomichi; Nishikawa, Takeshi; Otani, Kensuke; Sasaki, Kazuhito; Murono, Koji; Watanabe, Toshiaki

    2017-01-01

    Colorectal neuroendocrine tumors (NET) are a rare manifestation of colorectal neoplasia, requiring for radical dissection of the regional lymph nodes along with colorectal resection similar to that required for colorectal cancer. However, thus far, no reports have described the ability of computed tomography (CT) to predict lymph node involvement. In this study, we revealed the prediction rate of lymph node metastasis using contrast-enhanced CT. A total of 21 patients with colorectal NET undergoing colorectal resection were recruited from January 2010 to June 2016. We compared the CT findings between samples with or without pathologically proven lymph node metastasis, in each field (pericolic/perirectal and intermediate nodes). Within the pericolic/perirectal field, any lymph node larger than 5 mm in the CT images was a predictive indicator of lymph node metastasis with a sensitivity, specificity, and area under ROC curve (AUC) of 66.7%, 87.5%, and 0.844, respectively. Within the intermediate field, any visible lymph node on the CT was a predictive indicator of lymph node metastasis with a sensitivity, specificity, and AUC of 100%, 76.4%, and 0.890, respectively. In addition, when we observed lymph nodes larger than 3 mm on the CT images, the sensitivity and specificity were 100% and 82.4%, respectively, with an AUC of 0.8971. CT images provide predictive information for lymph node metastasis with a high rate of accuracy. Copyright© 2017, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.

  4. Dynamic four-dimensional computed tomography (4D CT) imaging for re-entry risk assessment in re-do sternotomy - first experience.

    PubMed

    Narayanan, Harish; Viana, Fabiano F; Smith, Julian A; Roumeliotis, Nicholas K; Troupis, Christopher J; Crossett, Marcus P; Troupis, John M

    2015-10-01

    Repeat cardiac surgeries are well known to have higher rates of complications, one of the important reasons being injuries associated with re-do sternotomy. Routine imaging with CT can help to minimise this risk by pre-operatively assessing the anatomical relation between the sternum and the underlying cardiovascular structures, but is limited by its inability to determine the presence and severity of functional tethering and adhesions between these structures. However, with the evolution of wide area detector MD CT scanners, it is possible to assess the presence of tethering using the dynamic four-dimensional CT (4D CT) imaging technique. Nineteen patients undergoing re-do cardiac surgery were pre-operatively imaged using dynamic 4D CT during regulated respiration. The datasets were assessed in cine mode for presence of differential motion between sternum and underlying cardiovascular structures which indicates lack of significant tethering. Overall, there was excellent correlation between preoperative imaging and intraoperative findings. The technique enabled our surgeons to meticulously plan the procedures and to avoid re-entry related injuries. Our initial experience shows that dynamic 4D CT is useful in risk stratification prior to re-do sternotomy by determining the presence or absence of tethering between sternum and underlying structures based on assessment of differential motion. Furthermore we determined the technique to be superior to non-dynamic assessment of retrocardiac tethering. Copyright © 2015 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  5. Post-operative re-bleeding in patients with hypertensive ICH is closely associated with the CT blend sign.

    PubMed

    Wu, Guofeng; Shen, Zhengkui; Wang, Likun; Sun, Shujie; Luo, Jinbiao; Mao, Yuanhong

    2017-07-06

    Intracranial post-operative re-haemorrhage is an important complication in patients with hypertensive intracerebral haemorrhage (ICH). The purpose of the present study was to determine the value of the computed tomography (CT) blend sign in predicting post-operative re-haemorrhage in patients with ICH. A total of 126 patients with ICH were included in the present study. All the patients underwent standard stereotactic minimally invasive surgery(MIS) to remove the ICH within 24 h following admission. There were 41 patients with a blend sign on initial CT and 85 patients without a blend sign on the initial CT. Multivariable logistic regression analyses were performed to assess the relationship between the presence of the blend sign on the non-enhanced admission CT scan and post-operative re-haemorrhage. Post-operative re-haemorrhage occurred in 24 of the 41 patients with the blend sign, and in 9 of the 85 patients without the blend sign. The incidence of re-haemorrhage was significantly different between the groups. The multivariate logistic regression analysis demonstrated that the initial Glasgow coma scale score (p = 0.002) and blend sign (P < 0.00) on the initial CT scan are independent predictors of post-operative re-haemorrhage. The sensitivity, specificity, and positive and negative predictive values of the blend sign for predicting post-operative re-haemorrhage were 72.7, 81.7, 58.5 and 89.4%, respectively. The presence of the blend sign on the initial CT scan is closely associated with post-operative re-haemorrhage in patients with ICH who undergo stereotactic MIS.

  6. CT and PET-CT of a Dog with Multiple Pulmonary Adenocarcinoma

    PubMed Central

    KIM, Jisun; KWON, Seong Young; CENA, Rohani; PARK, Seungjo; OH, Juyeon; OUI, Heejin; CHO, Kyoung-Oh; MIN, Jung-Joon; CHOI, Jihye

    2013-01-01

    ABSTRACT A 10-year-old, intact female Yorkshire terrier had multiple pulmonary nodules on thoracic radiography and ultrasonography with no lesions elsewhere. Computed tomography (CT) and positron emission tomography and computed tomography (PET-CT) using 18F-fluorodeoxyglucose (FDG) were performed to identify metastasis and undetected primary tumors. On CT examination, pulmonary nodules had a hypoattenuating center with thin peripheral enhancement, suggesting ischemic or necrotizing lesion. In PET-CT at 47 min after intravenous injection of 11.1 MBq/kg of FDG, the maximum standardized uptake value of each pulmonary nodule was about from 3.8 to 6.4. There were no abnormal lesions except for four pulmonary nodules on the CT and PET-CT. Primary lung tumor was tentatively diagnosed, and palliative therapy using 2 mg/kg tramadol and 2.2 mg/kg carprofen twice per day was applied. After the dog’s euthanasia due to deteriorated clinical signs and poor prognosis, undifferentiated pulmonary adenocarcinoma was diagnosed through histopathologic and immunochemistry examination. To the best of the authors’ knowledge, this is the first study of CT and PET-CT features of canine pulmonary adenocarcinoma. In this case, multiple pulmonary adenocarcinoma could be determined on the basis of FDG PET-CT through screening the obvious distant metastasis and/or lymph node invasions and excluding unknown primary tumors. PMID:24389742

  7. [Evaluation of upper cervical spine injury (C1-C2) with computed tomography].

    PubMed

    Siemianowicz, Anna; Baron, Jan; Wawrzynek, Wojciech; Koczy, Bogdan; Kasprowska, Sabina

    2006-01-01

    Cervical spine injuries are common and essential diagnostic problem. Diagnostic imaging is necessary for proper and effective treatment. Helical computed tomography (CT) and plain radiography are the basic diagnostic methods in cervical spine injuries. The purpose of this work was the comparison of CT examination of the upper cervical spine (CI-C2) with patients' clinical state. Twenty four patients (17 men and 7 women) were introduced into the study. The most common cause of cervical spine injuries were car accidents (48.5%). CT examination was performed in all patients. Six patients (25%) had multilevel injury, localized at C1-C2 level and in the lower part of cervical spine. The main pathology diagnosed by CT in the studied group was rotatory subluxation (66.6%). Eight patients (33.3%), with rotatory subluxation did not present any abnormalities in neurological examination performed immediately after the admission to the hospital. C1 and/or C2 fractures were diagnosed in 11 patients (45.8%), in some cases (in 3 patients - 12.5%) they were accompanied by rotatory subluxations. CT examination is the basic technique of diagnostic imaging in a case of cervical spine injuries. It enables quick, accurate and precise evaluation of bone structures and surrounding soft tissues. CT also enables multiplanar imaging and 3-dimentional imaging.

  8. Clinically Unjustified Diagnostic Imaging – a Worrisome Tendency in Today’s Medical Practice

    PubMed Central

    Sobiecka, Aleksandra; Bekiesińska-Figatowska, Monika; Rutkowska, Milena; Latos, Tomasz; Walecki, Jerzy

    2016-01-01

    Summary Background The purpose of the study was to evaluate the percentage of unjustified examinations among all the CT and MRI studies performed by two radiology departments and to determine the types of examinations which are most commonly carried out unnecessarily. Material/Methods Three radiologists assessed the justification of CT and MRI examinations performed during a period of 14 days based on the referrals. The radiologists assessed 799 referrals for CT scans (847 examinations of a particular part of the body) and 269 MRI referrals (269 examinations). The criteria for justification were: medical expertise and the guidelines. During the first stage radiologists divided the examinations into 3 groups: justified, unjustified and the examinations of questionable justification. The second step was to determine the reasons why the studies were considered as unjustified or of questionable justification. Results 73 of 1116 examinations (6.54%) were considered to be unjustified or of a questionable justification. There were 59 CT scans (59/847=6.97%) and 14 MRI studies (14/269=5.20%). The most common reasons to consider them as unjustified or of questionable justification were: inadequate method of diagnostic imaging chosen as a first-line tool and lacking or insufficient clinical details. Conclusions In our investigation 6.54% of both CT and MRI examinations were considered as unjustified or of questionable justification, which is lower than described in other studies (from 7% to 26%). The assessment was based only on referrals, therefore a total share of these examinations is likely to be higher. PMID:27471577

  9. Bone suppression in CT angiography data by region-based multiresolution segmentation

    NASA Astrophysics Data System (ADS)

    Blaffert, Thomas; Wiemker, Rafael; Lin, Zhong Min

    2003-05-01

    Multi slice CT (MSCT) scanners have the advantage of high and isotropic image resolution, which broadens the range of examinations for CT angiography (CTA). A very important method to present the large amount of high-resolution 3D data is the visualization by maximum intensity projections (MIP). A problem with MIP projections in angiography is that bones often hide the vessels of interest, especially the scull and vertebral column. Software tools for a manual selection of bone regions and their suppression in the MIP are available, but processing is time-consuming and tedious. A highly computer-assisted of even fully automated suppression of bones would considerably speed up the examination and probably increase the number of examined cases. In this paper we investigate the suppression (or removal) of bone regions in 3D CT data sets for vascular examinations of the head with a visualization of the carotids and the circle of Willis.

  10. Comparative analysis of ERCP, IDUS, EUS and CT in predicting malignant bile duct strictures

    PubMed Central

    Heinzow, Hauke S; Kammerer, Sara; Rammes, Carina; Wessling, Johannes; Domagk, Dirk; Meister, Tobias

    2014-01-01

    AIM: To compare endoscopic retrograde cholangio-pancreatography (ERCP), intraductal ultrasound (IDUS), endosonography (EUS), endoscopic transpapillary forceps biopsies (ETP) and computed tomography (CT) with respect to diagnosing malignant bile duct strictures. METHODS: A patient cohort with bile duct strictures of unknown etiology was examined by ERCP and IDUS, ETP, EUS, and CT. The sensitivity, specificity, and accuracy rates of the diagnostic procedures were calculated based on the definite diagnoses proved by histopathology or long-term follow-up in those patients who did not undergo surgery. For each of the diagnostic measures, the sensitivity, specificity, and accuracy rates were calculated. In all cases, the gold standard was the histopathologic staging of specimens or long-term follow-up of at least 12 mo. A comparison of the accuracy rates between the localization of strictures was performed by using the Mann-Whitney U-test and the χ2 test as appropriate. A comparison of the accuracy rates between the diagnostic procedures was performed by using the McNemar’s test. Differences were considered statistically significant if P < 0.05. RESULTS: A total of 234 patients (127 males, 107 females, median age 64, range 20-90 years) with indeterminate bile duct strictures were included. A total of 161 patients underwent operative exploration; thus, a surgical histopathological correlation was available for those patients. A total of 113 patients had malignant disease proven by surgery; in 48 patients, benign disease was surgically found. In these patients, the decision for surgical exploration was made due to the suspicion of malignant disease in multimodal diagnostics (ERCP, CT, or EUS). Fifty patients had a benign diagnosis and were followed by a surveillance protocol with a follow-up of at least 12 mo; the median follow-up was 34 mo. Twenty-three patients had extended malignant disease, and thus were considered palliative. A comparison of the different diagnostic tools for detecting bile duct malignancy resulted in accuracy rates of 91% (ERCP/IDUS), 59% (ETP), 92% (IDUS + ETP), 74% (EUS), and 73% (CT), respectively. In the subgroup analysis, the accuracy rates (%, ERCP + IDUS/ETP/IDUS + ETP; EUS; CT) for each tumor entity were as follows: cholangiocellular carcinoma: 92%/74%/92%/70%/79%; pancreatic carcinoma: 90%/68%/90%/81%/76%; and ampullary carcinoma: 88%/90%/90%/76%/76%. The detection rate of malignancy by ERCP/IDUS was superior to ETP (91% vs 59%, P < 0.0001), EUS (91% vs 74%, P < 0.0001) and CT (91% vs 73%, P < 0.0001); EUS was comparable to CT (74% vs 73%, P = 0.649). When analyzing accuracy rates with regard to localization of the bile duct stenosis, the accuracy rate of EUS for proximal vs distal stenosis was significantly higher for distal stenosis (79% vs 57%, P < 0.0001). CONCLUSION: ERCP/IDUS is superior to EUS and CT in providing accurate diagnoses of bile duct strictures of uncertain etiology. Multimodal diagnostics is recommended. PMID:25132767

  11. Capillary Thrombosis in the Skin: A Pathologic Hallmark of Severe/Chronic Rejection of Human Vascularized Composite Tissue Allografts?

    PubMed

    Kanitakis, Jean; Petruzzo, Palmina; Gazarian, Aram; Karayannopoulou, Georgia; Buron, Fannie; Dubois, Valérie; Thaunat, Olivier; Badet, Lionel; Morelon, Emmanuel

    2016-04-01

    Vascularized composite tissue allografts (VCA) can undergo rejection, manifesting pathologically with skin changes that form the basis of the Banff 2007 classification of VCA rejection. We have followed 10 human VCA recipients (7 with hand allografts, 3 with face allografts) for pathological signs of rejection. All of them developed episodes of acute rejection. Two patients with hand allografts presented in some of their skin biopsies an as yet unreported pathological finding in human VCA, consisting of capillary thromboses (CT) in the upper dermis. Capillary thrombosis was associated with other typical changes of grade II to III VCA rejection, namely, perivascular T cell infiltrates, but not with vascular C4d deposits (in formalin-fixed tissue). Clinically, the lesions presented as red or violaceous (lichenoid) cutaneous maculopapules. The first patient had several episodes of acute rejection during the 7-year follow-up. The second patient developed donor-specific antibodies; some months after CT were first observed, he developed chronic rejection leading to partial amputation of the allograft. Pathological examination of the skin showed graft vasculopathy and occasional C4d deposits in cutaneous capillaries. Capillary thrombosis seems to be a novel pathologic finding associated with human VCA rejection. Although its mechanism (immunologic vs nonimmunologic) remains unclear, this finding could carry an unfavorable prognostic significance, prompting close monitoring of the patients for severe/chronic rejection.

  12. Rationale and design of the Measuring Athlete's Risk of Cardiovascular events (MARC) study : The role of coronary CT in the cardiovascular evaluation of middle-aged sportsmen.

    PubMed

    Braber, T L; Mosterd, A; Prakken, N H J; Doevendans, P A F M; Mali, W P Th M; Backx, F J G; Grobbee, D E; Rienks, R; Nathoe, H M; Bots, M L; Velthuis, B K

    2015-02-01

    More than 90 % of exercise-related cardiac arrests occur in men, predominantly those aged 45 years and older with coronary artery disease (CAD) as the main cause. The current sports medical evaluation (SME) of middle-aged recreational athletes consists of a medical history, physical examination, and resting and exercise electrocardiography. Coronary CT (CCT) provides a minimally invasive low radiation dose opportunity to image the coronary arteries. We present the study protocol of the Measuring Athlete's Risk of Cardiovascular events (MARC) study. MARC aims to assess the additional value of CCT to a routine SME in asymptomatic sportsmen ≥45 years without known CAD. MARC is a prospective study of 300 asymptomatic sportsmen ≥45 years who will undergo CCT if the SME does not reveal any cardiac abnormalities. The prevalence and determinants of CAD (coronary artery calcium score ≥100 Agatston Units (AU) or ≥50 % luminal stenosis) will be reported. The number needed to screen to prevent the occurrence of one cardiovascular event in the next 5 years, conditional to adequate treatment, will be estimated. We aim to determine the prevalence and severity of CAD and the additional value of CCT in asymptomatic middle-aged (≥45 years) sportsmen whose routine SME revealed no cardiac abnormalities.

  13. CT of Normal Developmental and Variant Anatomy of the Pediatric Skull: Distinguishing Trauma from Normality.

    PubMed

    Idriz, Sanjin; Patel, Jaymin H; Ameli Renani, Seyed; Allan, Rosemary; Vlahos, Ioannis

    2015-01-01

    The use of computed tomography (CT) in clinical practice has been increasing rapidly, with the number of CT examinations performed in adults and children rising by 10% per year in England. Because the radiology community strives to reduce the radiation dose associated with pediatric examinations, external factors, including guidelines for pediatric head injury, are raising expectations for use of cranial CT in the pediatric population. Thus, radiologists are increasingly likely to encounter pediatric head CT examinations in daily practice. The variable appearance of cranial sutures at different ages can be confusing for inexperienced readers of radiologic images. The evolution of multidetector CT with thin-section acquisition increases the clarity of some of these sutures, which may be misinterpreted as fractures. Familiarity with the normal anatomy of the pediatric skull, how it changes with age, and normal variants can assist in translating the increased resolution of multidetector CT into more accurate detection of fractures and confident determination of normality, thereby reducing prolonged hospitalization of children with normal developmental structures that have been misinterpreted as fractures. More important, the potential morbidity and mortality related to false-negative interpretation of fractures as normal sutures may be avoided. The authors describe the normal anatomy of all standard pediatric sutures, common variants, and sutural mimics, thereby providing an accurate and safe framework for CT evaluation of skull trauma in pediatric patients. (©)RSNA, 2015.

  14. Investigation of ultra low-dose scans in the context of quantum-counting clinical CT

    NASA Astrophysics Data System (ADS)

    Weidinger, T.; Buzug, T. M.; Flohr, T.; Fung, G. S. K.; Kappler, S.; Stierstorfer, K.; Tsui, B. M. W.

    2012-03-01

    In clinical computed tomography (CT), images from patient examinations taken with conventional scanners exhibit noise characteristics governed by electronics noise, when scanning strongly attenuating obese patients or with an ultra-low X-ray dose. Unlike CT systems based on energy integrating detectors, a system with a quantum counting detector does not suffer from this drawback. Instead, the noise from the electronics mainly affects the spectral resolution of these detectors. Therefore, it does not contribute to the image noise in spectrally non-resolved CT images. This promises improved image quality due to image noise reduction in scans obtained from clinical CT examinations with lowest X-ray tube currents or obese patients. To quantify the benefits of quantum counting detectors in clinical CT we have carried out an extensive simulation study of the complete scanning and reconstruction process for both kinds of detectors. The simulation chain encompasses modeling of the X-ray source, beam attenuation in the patient, and calculation of the detector response. Moreover, in each case the subsequent image preprocessing and reconstruction is modeled as well. The simulation-based, theoretical evaluation is validated by experiments with a novel prototype quantum counting system and a Siemens Definition Flash scanner with a conventional energy integrating CT detector. We demonstrate and quantify the improvement from image noise reduction achievable with quantum counting techniques in CT examinations with ultra-low X-ray dose and strong attenuation.

  15. Analysis of appropriateness of outpatient CT and MRI referred from primary care clinics at an academic medical center: how critical is the need for improved decision support?

    PubMed

    Lehnert, Bruce E; Bree, Robert L

    2010-03-01

    The aim of this study was to retrospectively analyze a large group of CT and MRI examinations for appropriateness using evidence-based guidelines. The authors reviewed medical records from 459 elective outpatient CT and MR examinations from primary care physicians. Evidence-based appropriateness criteria from a radiology benefit management company were used to determine if the examination would have met criteria for approval. Submitted clinical history at the time of interpretation and clinic notes and laboratory results preceding the date of the imaging study were examined to simulate a real-time consultation with the referring provider. The radiology reports and subsequent clinic visits were analyzed for outcomes. Of the 459 examinations reviewed, 284 (62%) were CT and 175 (38%) were MRI. Three hundred forty-one (74%) were considered appropriate, and 118 (26%) were not considered appropriate. Examples of inappropriate examinations included brain CT for chronic headache, lumbar spine MR for acute back pain, knee or shoulder MRI in patients with osteoarthritis, and CT for hematuria during a urinary tract infection. Fifty-eight percent of the appropriate studies had positive results and affected subsequent management, whereas only thirteen percent [corrected] of inappropriate studies had positive results and affected management. A high percentage of examinations not meeting appropriateness criteria and subsequently yielding negative results suggests a need for tools to help primary care physicians improve the quality of their imaging decision requests. In the current environment, which stresses cost containment and comparative effectiveness, traditional radiology benefit management tools are being challenged by clinical decision support, with an emphasis on provider education coupled with electronic order entry systems.

  16. Incidental findings in children with blunt head trauma evaluated with cranial CT scans.

    PubMed

    Rogers, Alexander J; Maher, Cormac O; Schunk, Jeff E; Quayle, Kimberly; Jacobs, Elizabeth; Lichenstein, Richard; Powell, Elizabeth; Miskin, Michelle; Dayan, Peter; Holmes, James F; Kuppermann, Nathan

    2013-08-01

    Cranial computed tomography (CT) scans are frequently obtained in the evaluation of blunt head trauma in children. These scans may detect unexpected incidental findings. The objectives of this study were to determine the prevalence and significance of incidental findings on cranial CT scans in children evaluated for blunt head trauma. This was a secondary analysis of a multicenter study of pediatric blunt head trauma. Patients <18 years of age with blunt head trauma were eligible, with those undergoing cranial CT scan included in this substudy. Patients with coagulopathies, ventricular shunts, known previous brain surgery or abnormalities were excluded. We abstracted radiology reports for nontraumatic findings. We reviewed and categorized findings by their clinical urgency. Of the 43,904 head-injured children enrolled in the parent study, 15,831 underwent CT scans, and these latter patients serve as the study cohort. On 670 of these scans, nontraumatic findings were identified, with 16 excluded due to previously known abnormalities or surgeries. The remaining 654 represent a 4% prevalence of incidental findings. Of these, 195 (30%), representing 1% of the overall sample, warranted immediate intervention or outpatient follow-up. A small but important number of children evaluated with CT scans after blunt head trauma had incidental findings. Physicians who order cranial CTs must be prepared to interpret incidental findings, communicate with families, and ensure appropriate follow-up. There are ethical implications and potential health impacts of informing patients about incidental findings.

  17. SPECT/CT with radiolabeled somatostatin analogues in the evaluation of systemic granulomatous infections.

    PubMed

    Monteiro, Paulo Henrique Silva; de Souza, Thiago Ferreira; Moretti, Maria Luiza; Resende, Mariangela Ribeiro; Mengatti, Jair; de Lima, Mariana da Cunha Lopes; Santos, Allan Oliveira; Ramos, Celso Darío

    2017-01-01

    To evaluate SPECT/CT with radiolabeled somatostatin analogues (RSAs) in systemic granulomatous infections in comparison with gallium-67 ( 67 Ga) citrate scintigraphy. We studied 28 patients with active systemic granulomatous infections, including tuberculosis, paracoccidioidomycosis, pneumocystosis, cryptococcosis, aspergillosis, leishmaniasis, infectious vasculitis, and an unspecified opportunistic infection. Of the 28 patients, 23 had started specific treatment before the study outset. All patients underwent whole-body SPECT/CT imaging: 7 after injection of 99m Tc-EDDA-HYNIC-TOC, and 21 after injection of 111 In-DTPA-octreotide. All patients also underwent 67 Ga citrate imaging, except for one patient who died before the 67 Ga was available. In 20 of the 27 patients who underwent imaging with both tracers, 27 sites of active disease were detected by 67 Ga citrate imaging and by SPECT/CT with an RSA. Both tracers had negative results in the other 7 patients. RSA uptake was visually lower than 67 Ga uptake in 11 of the 20 patients with positive images and similar to 67 Ga uptake in the other 9 patients. The only patient who did not undergo 67 Ga scintigraphy underwent 99m Tc-EDDA-HYNIC-TOC SPECT/CT-guided biopsy of a lung cavity with focal RSA uptake, which turned to be positive for aspergillosis. SPECT/CT with 99m Tc-EDDA-HYNIC-TOC or 111 In-DTPA-octreotide seems to be a good alternative to 67 Ga citrate imaging for the evaluation of patients with systemic granulomatous disease.

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shen, Z; Greskovich, J; Xia, P

    Purpose: To generate virtual phantoms with clinically relevant deformation and use them to objectively evaluate geometric and dosimetric uncertainties of deformable image registration (DIR) algorithms. Methods: Ten lung cancer patients undergoing adaptive 3DCRT planning were selected. For each patient, a pair of planning CT (pCT) and replanning CT (rCT) were used as the basis for virtual phantom generation. Manually adjusted meshes were created for selected ROIs (e.g. PTV, lungs, spinal cord, esophagus, and heart) on pCT and rCT. The mesh vertices were input into a thin-plate spline algorithm to generate a reference displacement vector field (DVF). The reference DVF wasmore » used to deform pCT to generate a simulated replanning CT (srCT) that was closely matched to rCT. Three DIR algorithms (Demons, B-Spline, and intensity-based) were applied to these ten virtual phantoms. The images, ROIs, and doses were mapped from pCT to srCT using the DVFs computed by these three DIRs and compared to those mapped using the reference DVF. Results: The average Dice coefficients for selected ROIs were from 0.85 to 0.96 for Demons, from 0.86 to 0.97 for intensity-based, and from 0.76 to 0.95 for B-Spline. The average Hausdorff distances for selected ROIs were from 2.2 to 5.4 mm for Demons, from 2.3 to 6.8 mm for intensity-based, and from 2.4 to 11.4 mm for B-Spline. The average absolute dose errors for selected ROIs were from 0.2 to 0.6 Gy for Demons, from 0.1 to 0.5 Gy for intensity-based, and from 0.5 to 1.5 Gy for B-Spline. Conclusion: Virtual phantoms were modeled after patients with lung cancer and were clinically relevant for adaptive radiotherapy treatment replanning. Virtual phantoms with known DVFs serve as references and can provide a fair comparison when evaluating different DIRs. Demons and intensity-based DIRs were shown to have smaller geometric and dosimetric uncertainties than B-Spline. Z Shen: None; K Bzdusek: an employee of Philips Healthcare; J Greskovich: None; P Xia: received research grants from Philips Healthcare and Siemens Healthcare.« less

  19. Adaptive statistical iterative reconstruction: reducing dose while preserving image quality in the pediatric head CT examination.

    PubMed

    McKnight, Colin D; Watcharotone, Kuanwong; Ibrahim, Mohannad; Christodoulou, Emmanuel; Baer, Aaron H; Parmar, Hemant A

    2014-08-01

    Over the last decade there has been escalating concern regarding the increasing radiation exposure stemming from CT exams, particularly in children. Adaptive statistical iterative reconstruction (ASIR) is a relatively new and promising tool to reduce radiation dose while preserving image quality. While encouraging results have been found in adult head and chest and body imaging, validation of this technique in pediatric population is limited. The objective of our study was to retrospectively compare the image quality and radiation dose of pediatric head CT examinations obtained with ASIR compared to pediatric head CT examinations without ASIR in a large patient population. Retrospective analysis was performed on 82 pediatric head CT examinations. This group included 33 pediatric head CT examinations obtained with ASIR and 49 pediatric head CT examinations without ASIR. Computed tomography dose index (CTDIvol) was recorded on all examinations. Quantitative analysis consisted of standardized measurement of attenuation and the standard deviation at the bilateral centrum semiovale and cerebellar white matter to evaluate objective noise. Qualitative analysis consisted of independent assessment by two radiologists in a blinded manner of gray-white differentiation, sharpness and overall diagnostic quality. The average CTDIvol value of the ASIR group was 21.8 mGy (SD = 4.0) while the average CTDIvol for the non-ASIR group was 29.7 mGy (SD = 13.8), reflecting a statistically significant reduction in CTDIvol in the ASIR group (P < 0.01). There were statistically significant reductions in CTDI for the 3- to 12-year-old ASIR group as compared to the 3- to 12-year-old non-ASIR group (21.5 mGy vs. 30.0 mGy; P = 0.004) as well as statistically significant reductions in CTDI for the >12-year-old ASIR group as compared to the >12-year-old non-ASIR group (29.7 mGy vs. 49.9 mGy; P = 0.0002). Quantitative analysis revealed no significant difference in the homogeneity of variance in the ASIR group compared to the non-ASIR group. Radiologist assessment of gray-white differentiation, sharpness and overall diagnostic quality in ASIR examinations was not substantially different compared to non-ASIR examinations. The use of ASIR in pediatric head CT examinations allows for a 28% CTDIvol reduction in the 3- to 12-year-old age group and a 48% reduction in the >12-year-old age group without substantially affecting image quality.

  20. WE-B-207-02: CT Lung Cancer Screening and the Medical Physicist: A Dosimetry Summary of CT Participants in the National Lung Cancer Screening Trial (NLST)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, C.

    2015-06-15

    The US National Lung Screening Trial (NLST) was a multi-center randomized, controlled trial comparing a low-dose CT (LDCT) to posterior-anterior (PA) chest x-ray (CXR) in screening older, current and former heavy smokers for early detection of lung cancer. Recruitment was launched in September 2002 and ended in April 2004 when 53,454 participants had been randomized at 33 screening sites in equal proportions. Funded by the National Cancer Institute this trial demonstrated that LDCT screening reduced lung cancer mortality. The US Preventive Services Task Force (USPSTF) cited NLST findings and conclusions in its deliberations and analysis of lung cancer screening. Undermore » the 2010 Patient Protection and Affordable Care Act, the USPSTF favorable recommendation regarding lung cancer CT screening assisted in obtaining third-party payers coverage for screening. The objective of this session is to provide an introduction to the NLST and the trial findings, in addition to a comprehensive review of the dosimetry investigations and assessments completed using individual NLST participant CT and CXR examinations. Session presentations will review and discuss the findings of two independent assessments, a CXR assessment and the findings of a CT investigation calculating individual organ dosimetry values. The CXR assessment reviewed a total of 73,733 chest x-ray exams that were performed on 92 chest imaging systems of which 66,157 participant examinations were used. The CT organ dosimetry investigation collected scan parameters from 23,773 CT examinations; a subset of the 75,133 CT examinations performed using 97 multi-detector CT scanners. Organ dose conversion coefficients were calculated using a Monte Carlo code. An experimentally-validated CT scanner simulation was coupled with 193 adult hybrid computational phantoms representing the height and weight of the current U.S. population. The dose to selected organs was calculated using the organ dose library and the abstracted scan parameters. This session will review the results and summarize the individualized doses to major organs and the mean effective dose and CTDIvol estimate for 66,157 PA chest and 23,773 CT examinations respectively, using size-dependent computational phantoms coupled with Monte Carlo calculations. Learning Objectives: Review and summarize relevant NLST findings and conclusions. Understand the scope and scale of the NLST specific to participant dosimetry. Provide a comprehensive review of NLST participant dosimetry assessments. Summarize the results of an investigation providing individualized organ dose estimates for NLST participant cohorts.« less

  1. Jejunal perforation after abdominal liposuction, bilateral breast augmentation and facial fat grafting

    PubMed Central

    Coronado-Malagón, Martin; Tauffer-Carrion, Luis Tomas

    2012-01-01

    A 54-year-old woman presented to the emergency department 24 h after undergoing abdominal liposuction, bilateral breast augmentation and facial fat grafting at a private plastic surgery clinic. She presented with the classic evolution of a bowel perforation secondary to abdominal liposuction. A computed tomography (CT) scan found free air in her abdominal cavity. Based on the CT scan and the persistent pain experienced by the patient, an abdominal laparatomy was urgently performed. A jejunum perforation was found and was treated with a resection of the affected segment followed by intestinal anastomosis. The patient had a successful recovery and was discharged seven days later. The present article also reviews the classical presentation of a bowel perforation following abdominal liposuction. PMID:23997589

  2. Jejunal perforation after abdominal liposuction, bilateral breast augmentation and facial fat grafting.

    PubMed

    Coronado-Malagón, Martin; Tauffer-Carrion, Luis Tomas

    2012-01-01

    A 54-year-old woman presented to the emergency department 24 h after undergoing abdominal liposuction, bilateral breast augmentation and facial fat grafting at a private plastic surgery clinic. She presented with the classic evolution of a bowel perforation secondary to abdominal liposuction. A computed tomography (CT) scan found free air in her abdominal cavity. Based on the CT scan and the persistent pain experienced by the patient, an abdominal laparatomy was urgently performed. A jejunum perforation was found and was treated with a resection of the affected segment followed by intestinal anastomosis. The patient had a successful recovery and was discharged seven days later. The present article also reviews the classical presentation of a bowel perforation following abdominal liposuction.

  3. Heteroplasmy and evidence for recombination in the mitochondrial control region of the flatfish Platichthys flesus.

    PubMed

    Hoarau, Galice; Holla, Suzanne; Lescasse, Rachel; Stam, Wytze T; Olsen, Jeanine L

    2002-12-01

    The general assumption that mitochondrial DNA (mtDNA) does not undergo recombination has been challenged recently in invertebrates. Here we present the first direct evidence for recombination in the mtDNA of a vertebrate, the flounder Platichthys flesus. The control region in the mtDNA of this flatfish is characterized by the presence of a variable number of tandem repeats and a high level of heteroplasmy. Two types of repeats were recognized, differing by two C-T point mutations. Most individuals carry a pure "C" or a pure "T" array, but one individual showed a compound "CT" array. Such a compound array is evidence for recombination in the mtDNA control region from the flounder.

  4. An Evaluation of Critical Thinking Competencies in Business Settings

    ERIC Educational Resources Information Center

    Dwyer, Christopher P.; Boswell, Amy; Elliott, Mark A.

    2015-01-01

    Although critical thinking (CT) skills are usually considered as domain general (Gabbenesch, 2006; Halpern, 2003), CT ability may benefit from expertise knowledge and skill. The current study examined both general CT ability and CT ability related to business scenarios for individuals (a) expert in business, (b) novice in business, and (c) with no…

  5. Multi-national findings on radiation protection of children.

    PubMed

    Rehani, Madan M

    2014-10-01

    This article reviews issues of radiation protection in children in 52 low-resource countries. Extensive information was obtained through a survey by the International Atomic Energy Agency (IAEA); wide-ranging information was available from 40 countries and data from the other countries pertained to frequency of pediatric CT examinations. Of note is that multi-detector CT (MDCT) was available in 77% of responses to the survey, typically nodal centers in these countries. Nearly 75% of these scanners were reported to have dose displays. The pediatric CT usage was lower in European facilities as compared to Asian and African facilities, where usage was twice as high. The most frequently scanned body part was the head. Frequent use of 120 kVp was reported in children. The ratio of maximum to minimum CT dose index volume (CTDIvol) values varied between 15 for abdomen CT in the age group 5-10 years and 100 for chest CT in the age group <1 year. In 8% of the CT systems, CTDI values for pediatric patients were higher than those for adults in at least one age group and for one type of examination. Use of adult protocols for children was associated with CTDIw or CTDIvol values in children that were double those of adults for head and chest examination and 50% higher for abdomen examination. Patient dose records were kept in nearly half of the facilities, with the highest frequency in Europe (55% of participating facilities), and in 49% of Asian, 36% of Latin American and 14% of African facilities. The analysis of the first-choice examinations in seven clinical conditions showed that practice was in accordance with guidelines for only three of seven specified clinical conditions.

  6. Optimized enhancement in helical CT: experiences with a real-time bolus tracking system in 628 patients.

    PubMed

    Kirchner, J; Kickuth, R; Laufer, U; Noack, M; Liermann, D

    2000-05-01

    Ultrafast detector technology enables bolus-triggered application of contrast media. In a prospective study we investigated the benefit of this new method with the intention of optimizing enhancement during examination of the chest and abdomen. In total, we examined 548 patients under standardized conditions. All examinations were performed on a Somatom Plus 4 Power CT system (Siemens Corp., Forchheim, Germany) using the CARE-Bolus software. This produces repetitive low-dose test images (e.g. for the lung: 140 kV, 43 mA, TI 0.5 s) and measures the Hounsfield attenuation in a pre-selected region of interest. After exceeding a defined threshold, a diagnostic spiral CT examination was begun automatically. The data obtained from 321 abdominal CT and 179 lung CT examinations were correlated with different parameters such as age, weight and height of the patients and parameters of vascular access. In a group of 80 patients, the injection of contrast medium was stopped after reaching a pre-defined threshold of an increase of 100 HU over the baseline. Then, we assessed the maximal enhancement of liver, pulmonal artery trunk and aortic arch. There was no correlation between bolus geometry and age, body surface or weight. In helical CT of the abdomen the threshold was reached after a mean trigger time of 27 s (range 13-67 s) and only 65 ml (range 41-105 ml) of contrast medium were administered. In helical CT of the lung the threshold was reached after 21 s (range 12-48 s) and the mean amount of administered contrast medium was 48 ml (range 38-71 ml). Bolus triggering allows optimized enhancement of the organs and reduces the dose of contrast material required compared with standard administration. Copyright 2000 The Royal College of Radiologists.

  7. Are the studies on cancer risk from CT scans biased by indication? Elements of answer from a large-scale cohort study in France.

    PubMed

    Journy, N; Rehel, J-L; Ducou Le Pointe, H; Lee, C; Brisse, H; Chateil, J-F; Caer-Lorho, S; Laurier, D; Bernier, M-O

    2015-01-06

    Recent epidemiological results suggested an increase of cancer risk after receiving computed tomography (CT) scans in childhood or adolescence. Their interpretation is questioned due to the lack of information about the reasons for examination. Our objective was to estimate the cancer risk related to childhood CT scans, and examine how cancer-predisposing factors (PFs) affect assessment of the radiation-related risk. The cohort included 67,274 children who had a first scan before the age of 10 years from 2000 to 2010 in 23 French departments. Cumulative X-rays doses were estimated from radiology protocols. Cancer incidence was retrieved through the national registry of childhood cancers; PF from discharge diagnoses. During a mean follow-up of 4 years, 27 cases of tumours of the central nervous system, 25 of leukaemia and 21 of lymphoma were diagnosed; 32% of them among children with PF. Specific patterns of CT exposures were observed according to PFs. Adjustment for PF reduced the excess risk estimates related to cumulative doses from CT scans. No significant excess risk was observed in relation to CT exposures. This study suggests that the indication for examinations, whether suspected cancer or PF management, should be considered to avoid overestimation of the cancer risks associated with CT scans.

  8. Degenerative and regenerative features of myofibers differ among skeletal muscles in a murine model of muscular dystrophy.

    PubMed

    Ikeda, Teppei; Ichii, Osamu; Otsuka-Kanazawa, Saori; Nakamura, Teppei; Elewa, Yaser Hosny Ali; Kon, Yasuhiro

    2016-10-01

    Skeletal muscle myofibers constantly undergo degeneration and regeneration. Histopathological features of 6 skeletal muscles (cranial tibial [CT], gastrocnemius, quadriceps femoris, triceps brachii [TB], lumbar longissimus muscles, and costal part of the diaphragm [CPD]) were compared using C57BL/10ScSn-Dmd mdx (mdx) mice, a model for muscular dystrophy versus control, C57BL/10 mice. Body weight and skeletal muscle mass were lower in mdx mice than the control at 4 weeks of age; these results were similar at 6-30 weeks. Additionally, muscular lesions were observed in all examined skeletal muscles in mdx mice after 4 weeks, but none were noted in the controls. Immunohistochemical staining revealed numerous paired box 7-positive satellite cells surrounding the embryonic myosin heavy chain-positive regenerating myofibers, while the number of the former and staining intensity of the latter decreased as myofiber regeneration progressed. Persistent muscular lesions were observed in skeletal muscles of mdx mice between 4 and 14 weeks of age, and normal myofibers decreased with age. Number of muscular lesions was lowest in CPD at all ages examined, while the ratio of normal myofibers was lowest in TB at 6 weeks. In CT, TB, and CPD, Iba1-positive macrophages, the main inflammatory cells in skeletal muscle lesions, showed a significant positive correlation with the appearance of regenerating myofibers. Additionally, B220-positive B-cells showed positive and negative correlation with regenerating and regenerated myofibers, respectively. Our data suggest that degenerative and regenerative features of myofibers differ among skeletal muscles and that inflammatory cells are strongly associated with regenerative features of myofibers in mdx mice.

  9. Patient participation in cancer clinical trials: A pilot test of lay navigation.

    PubMed

    Cartmell, Kathleen B; Bonilha, Heather S; Matson, Terri; Bryant, Debbie C; Zapka, Jane G; Bentz, Tricia A; Ford, Marvella E; Hughes-Halbert, Chanita; Simpson, Kit N; Alberg, Anthony J

    2016-08-15

    Clinical trials (CT) represent an important treatment option for cancer patients. Unfortunately, patients face challenges to enrolling in CTs, such as logistical barriers, poor CT understanding and complex clinical regimens. Patient navigation is a strategy that may help to improve the delivery of CT education and support services. We examined the feasibility and initial effect of one navigation strategy, use of lay navigators. A lay CT navigation intervention was evaluated in a prospective cohort study among 40 lung and esophageal cancer patients. The intervention was delivered by a trained lay navigator who viewed a 17-minute CT educational video with each patient, assessed and answered their questions about CT participation and addressed reported barriers to care and trial participation. During this 12-month pilot project, 85% (95% CI: 72%-93%) of patients eligible for a therapeutic CT consented to participate in the CT navigation intervention. Among navigated patients, CT understanding improved between pre- and post-test (means 3.54 and 4.40, respectively; p-value 0.004), and 95% (95% CI: 82%-98%) of navigated patients consented to participate in a CT. Navigated patients reported being satisfied with patient navigation services and CT participation. In this formative single-arm pilot project, initial evidence was found for the potential effect of a lay navigation intervention on CT understanding and enrollment. A randomized controlled trial is needed to examine the efficacy of the intervention for improving CT education and enrollment.

  10. Investigating CT to CBCT image registration for head and neck proton therapy as a tool for daily dose recalculation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Landry, Guillaume, E-mail: g.landry@lmu.de; Nijhuis, Reinoud; Thieke, Christian

    2015-03-15

    Purpose: Intensity modulated proton therapy (IMPT) of head and neck (H and N) cancer patients may be improved by plan adaptation. The decision to adapt the treatment plan based on a dose recalculation on the current anatomy requires a diagnostic quality computed tomography (CT) scan of the patient. As gantry-mounted cone beam CT (CBCT) scanners are currently being offered by vendors, they may offer daily or weekly updates of patient anatomy. CBCT image quality may not be sufficient for accurate proton dose calculation and it is likely necessary to perform CBCT CT number correction. In this work, the authors investigatedmore » deformable image registration (DIR) of the planning CT (pCT) to the CBCT to generate a virtual CT (vCT) to be used for proton dose recalculation. Methods: Datasets of six H and N cancer patients undergoing photon intensity modulated radiation therapy were used in this study to validate the vCT approach. Each dataset contained a CBCT acquired within 3 days of a replanning CT (rpCT), in addition to a pCT. The pCT and rpCT were delineated by a physician. A Morphons algorithm was employed in this work to perform DIR of the pCT to CBCT following a rigid registration of the two images. The contours from the pCT were deformed using the vector field resulting from DIR to yield a contoured vCT. The DIR accuracy was evaluated with a scale invariant feature transform (SIFT) algorithm comparing automatically identified matching features between vCT and CBCT. The rpCT was used as reference for evaluation of the vCT. The vCT and rpCT CT numbers were converted to stopping power ratio and the water equivalent thickness (WET) was calculated. IMPT dose distributions from treatment plans optimized on the pCT were recalculated with a Monte Carlo algorithm on the rpCT and vCT for comparison in terms of gamma index, dose volume histogram (DVH) statistics as well as proton range. The DIR generated contours on the vCT were compared to physician-drawn contours on the rpCT. Results: The DIR accuracy was better than 1.4 mm according to the SIFT evaluation. The mean WET differences between vCT (pCT) and rpCT were below 1 mm (2.6 mm). The amount of voxels passing 3%/3 mm gamma criteria were above 95% for the vCT vs rpCT. When using the rpCT contour set to derive DVH statistics from dose distributions calculated on the rpCT and vCT the differences, expressed in terms of 30 fractions of 2 Gy, were within [−4, 2 Gy] for parotid glands (D{sub mean}), spinal cord (D{sub 2%}), brainstem (D{sub 2%}), and CTV (D{sub 95%}). When using DIR generated contours for the vCT, those differences ranged within [−8, 11 Gy]. Conclusions: In this work, the authors generated CBCT based stopping power distributions using DIR of the pCT to a CBCT scan. DIR accuracy was below 1.4 mm as evaluated by the SIFT algorithm. Dose distributions calculated on the vCT agreed well to those calculated on the rpCT when using gamma index evaluation as well as DVH statistics based on the same contours. The use of DIR generated contours introduced variability in DVH statistics.« less

  11. Identification and tissue distribution of mRNAs encoding salmon-type calcitonins-IV and -V in the rainbow trout.

    PubMed

    Hidaka, Yoshie; Suzuki, Masakazu

    2004-06-01

    Four types of calcitonin are produced in salmonid fish, although their functional diversity is almost unknown. To explore the significance of these isoforms, we have characterized salmon-type calcitonin (sCT) mRNAs in the rainbow trout (Oncorhynchus mykiss), and examined their tissue distribution. In addition to the previously isolated sCT-I cDNAs, two new forms of sCT cDNA were cloned from the ultimobranchial gland, and one of them (sCT-IV cDNA) was predicted to encode an N-terminal peptide of 80 amino acid residues, a putative cleavage site Lys-Arg, sCT-IV, a cleavage and amidation sequence Gly-Lys-Lys-Arg, and a C-terminal peptide of 18 amino acids. The sCT-IV precursor was 78% identical with the rainbow trout sCT-I precursors. The other cloned cDNA encoded a precursor for a novel CT, sCT-V. The sCT-V peptide was different from sCT-IV by only one amino acid residue: Val at position 8 in the latter was replaced by Met. The sCT-V precursor had 80 and 90% identity with the sCT-I and -IV precursors respectively. No cDNA clones were obtained for sCTs-II or -III.Tissue distribution of sCT-I, -IV and -V mRNAs was examined by RT-PCR and specific cleavage with restriction enzymes. An amplified fragment from sCT-I mRNA was detected not only in the ultimobranchial gland, but also in the gills, testis and ovary. RT-PCR analysis coupled to restriction digestion further revealed that sCT-IV mRNA was expressed in both the testis and the ultimobranchial gland. The expression sites of sCT-IV mRNA were localized to the Leydig cells of the testis and to the parenchymal cells of the ultimobranchial gland, by in situ hybridization histochemistry. Although the amino acid sequence of sCT-V peptide was nearly the same as that of sCT-IV, the sCT-V gene showed a much wider pattern of expression: the band amplified by RT-PCR was detected in all the tissues examined except the kidney, gills and blood cells. The sCT-V mRNA was shown to be localized in the parenchymal cells of the ultimobranchial gland, but not in other tissues at the cellular level, suggesting very low expression of sCT-V mRNA in those tissues. Our results show different patterns of tissue expression of three types of sCT genes in the rainbow trout, suggesting that sCTs-I, -IV and -V might differ in their local actions.

  12. Utility of multiple rule out CT screening of high-risk atraumatic patients in an emergency department-a feasibility study.

    PubMed

    Pries-Heje, Mia M; Hasselbalch, Rasmus B; Raaschou, Henriette; Rezanavaz-Gheshlagh, Bijan; Heebøll, Hanne; Rehman, Shazia; Kristensen, Mariana; Andersen, Erik Henning; Ravn, Lisbet; Nèmery, Michel C; Lind, Morten N; Boel, Thomas; Ulriksen, Peter Sommer; Iversen, Kasper K

    2018-02-17

    Several large trials have evaluated the effect of CT screening based on specific symptoms, with varying outcomes. Screening of patients with CT based on their prognosis alone has not been examined before. For moderate-to-high risk patients presenting in the emergency department (ED), the potential gain from a CT scan might outweigh the risk of radiation exposure. We hypothesized that an accelerated "multiple rule out" CT screening of moderate-to-high risk patients will detect many clinically unrecognized diagnoses that affect change in treatment. Patients ≥ 40 years, triaged as high-risk or moderate-to-high risk according to vital signs, were eligible for inclusion. Patients were scanned with a combined ECG-gated and dual energy CT scan of cerebrum, thorax, and abdomen. The impact of the CT scan on patient diagnosis and treatment was examined prospectively by an expert panel. A total of 100 patients were included in the study, (53% female, mean age 73 years [age range, 43-93]). The scan lead to change in treatment or additional examinations in 37 (37%) patients, of which 24 (24%) were diagnostically significant, change in acute treatment in 11 (11%) cases and previously unrecognized malignant tumors in 10 (10%) cases. The mean size specific radiation dose was 15.9 mSv (± 3.1 mSv). Screening with a multi-rule out CT scan of high-risk patients in an ED is feasible and result in discovery of clinically unrecognized diagnoses and malignant tumors, but at the cost of radiation exposure and downstream examinations. The clinical impact of these findings should be evaluated in a larger randomized cohort.

  13. A comparison of sequential and spiral scanning techniques in brain CT.

    PubMed

    Pace, Ivana; Zarb, Francis

    2015-01-01

    To evaluate and compare image quality and radiation dose of sequential computed tomography (CT) examinations of the brain and spiral CT examinations of the brain imaged on a GE HiSpeed NX/I Dual Slice 2CT scanner. A random sample of 40 patients referred for CT examination of the brain was selected and divided into 2 groups. Half of the patients were scanned using the sequential technique; the other half were scanned using the spiral technique. Radiation dose data—both the computed tomography dose index (CTDI) and the dose length product (DLP)—were recorded on a checklist at the end of each examination. Using the European Guidelines on Quality Criteria for Computed Tomography, 4 radiologists conducted a visual grading analysis and rated the level of visibility of 6 anatomical structures considered necessary to produce images of high quality. The mean CTDI(vol) and DLP values were statistically significantly higher (P <.05) with the sequential scans (CTDI(vol): 22.06 mGy; DLP: 304.60 mGy • cm) than with the spiral scans (CTDI(vol): 14.94 mGy; DLP: 229.10 mGy • cm). The mean image quality rating scores for all criteria of the sequential scanning technique were statistically significantly higher (P <.05) in the visual grading analysis than those of the spiral scanning technique. In this local study, the sequential technique was preferred over the spiral technique for both overall image quality and differentiation between gray and white matter in brain CT scans. Other similar studies counter this finding. The radiation dose seen with the sequential CT scanning technique was significantly higher than that seen with the spiral CT scanning technique. However, image quality with the sequential technique was statistically significantly superior (P <.05).

  14. Dual-source CT imaging to plan transcatheter aortic valve replacement: accuracy for diagnosis of obstructive coronary artery disease.

    PubMed

    Harris, Brett S; De Cecco, Carlo N; Schoepf, U Joseph; Steinberg, Daniel H; Bayer, Richard R; Krazinski, Aleksander W; Dyer, Kevin T; Sandhu, Monique K; Zile, Michael R; Meinel, Felix G

    2015-04-01

    To assess the accuracy of computed tomographic (CT) examinations performed for the purpose of transcatheter aortic valve replacement (TAVR) planning to diagnose obstructive coronary artery disease (CAD). With institutional review board approval, waivers of informed consent, and in compliance with HIPAA, 100 consecutive TAVR candidates (61 men, mean age 79.6 years ± 9.9) who underwent both TAVR planning CT (with a dual-source CT system) and coronary catheter (CC) angiographic imaging were retrospectively analyzed. At both modalities, the presence of stenosis in the native coronary arteries was assessed. Additionally, all coronary bypass grafts were rated as patent or occluded. With CC angiographic imaging as the reference standard, the accuracy of CT for lesion detection on a per-vessel and per-patient basis was calculated. The accuracy of CT for the assessment of graft patency was also analyzed. For per-vessel and per-patient analysis for the detection of stenosis that was 50% or more in the native coronary arteries, CT imaging had, respectively, 94.4% and 98.6% sensitivity, 68.4% and 55.6% specificity, 94.7% and 93.8% negative predictive value (NPV), and 67.0% and 85.7% positive predictive value. Per-patient sensitivity of stenosis 50% or greater with CT for greater than 70% stenosis at CC angiographic imaging was 100%. All 12 vessels in which percutaneous coronary intervention was performed were correctly identified as demonstrating stenosis 50% or greater with CT. There was agreement between CT and CC angiographic imaging regarding graft patency in 114 of 115 grafts identified with CC angiographic imaging. TAVR planning CT has high sensitivity and NPV in excluding obstructive CAD. An additional preprocedural CC angiographic examination may not be required in TAVR candidates with a CT examination that does not show obstructive CAD. © RSNA, 2014 Online supplemental material is available for this article.

  15. Ultra-Low-Dose Fetal CT With Model-Based Iterative Reconstruction: A Prospective Pilot Study.

    PubMed

    Imai, Rumi; Miyazaki, Osamu; Horiuchi, Tetsuya; Asano, Keisuke; Nishimura, Gen; Sago, Haruhiko; Nosaka, Shunsuke

    2017-06-01

    Prenatal diagnosis of skeletal dysplasia by means of 3D skeletal CT examination is highly accurate. However, it carries a risk of fetal exposure to radiation. Model-based iterative reconstruction (MBIR) technology can reduce radiation exposure; however, to our knowledge, the lower limit of an optimal dose is currently unknown. The objectives of this study are to establish ultra-low-dose fetal CT as a method for prenatal diagnosis of skeletal dysplasia and to evaluate the appropriate radiation dose for ultra-low-dose fetal CT. Relationships between tube current and image noise in adaptive statistical iterative reconstruction and MBIR were examined using a 32-cm CT dose index (CTDI) phantom. On the basis of the results of this examination and the recommended methods for the MBIR option and the known relationship between noise and tube current for filtered back projection, as represented by the expression SD = (milliamperes) -0.5 , the lower limit of the optimal dose in ultra-low-dose fetal CT with MBIR was set. The diagnostic power of the CT images obtained using the aforementioned scanning conditions was evaluated, and the radiation exposure associated with ultra-low-dose fetal CT was compared with that noted in previous reports. Noise increased in nearly inverse proportion to the square root of the dose in adaptive statistical iterative reconstruction and in inverse proportion to the fourth root of the dose in MBIR. Ultra-low-dose fetal CT was found to have a volume CTDI of 0.5 mGy. Prenatal diagnosis was accurately performed on the basis of ultra-low-dose fetal CT images that were obtained using this protocol. The level of fetal exposure to radiation was 0.7 mSv. The use of ultra-low-dose fetal CT with MBIR led to a substantial reduction in radiation exposure, compared with the CT imaging method currently used at our institution, but it still enabled diagnosis of skeletal dysplasia without reducing diagnostic power.

  16. Inter- and intrascanner variability of pulmonary nodule volumetry on low-dose 64-row CT: an anthropomorphic phantom study

    PubMed Central

    Xie, X; Willemink, M J; Zhao, Y; de Jong, P A; van Ooijen, P M A; Oudkerk, M; Greuter, M J W

    2013-01-01

    Objective: To assess inter- and intrascanner variability in volumetry of solid pulmonary nodules in an anthropomorphic thoracic phantom using low-dose CT. Methods: Five spherical solid artificial nodules [diameters 3, 5, 8, 10 and 12 mm; CT density +100 Hounsfield units (HU)] were randomly placed inside an anthropomorphic thoracic phantom in different combinations. The phantom was examined on two 64-row multidetector CT (64-MDCT) systems (CT-A and CT-B) from different vendors with a low-dose protocol. Each CT examination was performed three times. The CT examinations were evaluated twice by independent blinded observers. Nodule volume was semi-automatically measured by dedicated software. Interscanner variability was evaluated by Bland–Altman analysis and expressed as 95% confidence interval (CI) of relative differences. Intrascanner variability was expressed as 95% CI of relative variation from the mean. Results: No significant difference in CT-derived volume was found between CT-A and CT-B, except for the 3-mm nodules (p<0.05). The 95% CI of interscanner variability was within ±41.6%, ±18.2% and ±4.9% for 3, 5 and ≥8 mm nodules, respectively. The 95% CI of intrascanner variability was within ±28.6%, ±13.4% and ±2.6% for 3, 5 and ≥8 mm nodules, respectively. Conclusion: Different 64-MDCT scanners in low-dose settings yield good agreement in volumetry of artificial pulmonary nodules between 5 mm and 12 mm in diameter. Inter- and intrascanner variability decreases at a larger nodule size to a maximum of 4.9% for ≥8 mm nodules. Advances in knowledge: The commonly accepted cut-off of 25% to determine nodule growth has the potential to be reduced for ≥8 mm nodules. This offers the possibility of reducing the interval for repeated CT scans in lung cancer screenings. PMID:23884758

  17. Physical analysis of breast cancer using dual-source computed tomography

    NASA Astrophysics Data System (ADS)

    Kim, H. J.; Lee, H. K.; Cho, J. H.

    2014-12-01

    This study was aimed to analyze various physical characteristics of breast cancer using dual-source computed tomography (CT). A phantom study and a clinical trial were performed in order and a 64-multidetector CT device was used for the examinations. In the phantom study, single-source (SS) CT was set up with a conventional scanning condition that is usually applied for breast CT examination and implementation was done at tube voltage of 120 kVp. Dual-source CT acquired images by irradiating X-ray sources with fast switching between two kilovoltage settings (80 and 140 kVp). After scanning, Hounsfield Unit (HU) values and radiation doses in a region of interest were measured and analyzed. In the clinical trial, the HU values were measured and analyzed after single-source computed tomography (SSCT) and dual-source CT in patients diagnosed with breast cancer. Also, the tumor size measured by dual-source CT was compared with the actual tumor size. The phantom study determined that the tumor region was especially measured by dual-source CT, while nylon fiber and specks region were especially measured by SSCT. The radiation dose was high with dual-source CT. The clinical trial showed a higher HU value of cancerous regions when scanned by dual-source CT compared with SSCT.

  18. Significance of clinical examination, CT and MRI scan in the diagnosis of posterior pelvic ring fractures.

    PubMed

    Nüchtern, J V; Hartel, M J; Henes, F O; Groth, M; Jauch, S Y; Haegele, J; Briem, D; Hoffmann, M; Lehmann, W; Rueger, J M; Großterlinden, L G

    2015-02-01

    Patients with a fracture in the anterior pelvic ring often simultaneously demonstrate pain in the posterior pelvic ring. The aim of the present prospective study was to assess the sensitivity of CT, MRI and clinical examination in the detection of fractures in the posterior pelvic ring in patients with fractures of the anterior pelvic ring diagnosed in conventional radiographs. Sixty patients with radiographic signs of an anterior pelvic ring injury were included in this prospective analysis. Following a focused clinical examination of the posterior pelvis, all patients underwent both a CT and then a MRI scan of their pelvis. Two board certified radiologists evaluated the CT and MRI scans independently. To estimate the presence of osteoporosis the Hounsfield units of the vertebral body of L5 were measured in each case. Fifty-three women and seven men, with a mean age of 74.7+/-15.6 years were included into the study. A fracture of the posterior pelvic ring was found in fourty-eight patients (80%) patients using MRI. Fractures of the posterior pelvic ring would have been missed in eight cases (17%), if only CT had been used. Eighty-five percent of the patients with a posterior fracture had an osteoporosis. The majority of the cases suffered from a low energy trauma. Thirty-eight patients (83%) with positive clinical signs at the posterior pelvic ring actually had a fracture of the posterior pelvic ring in the MRI. The clinical examination proved to be equally effective to CT in detecting posterior pelvic ring fractures. The significance of both, clinical examination and CT was confirmed in the detection of fractures in the posterior pelvic ring. MRI examination of the pelvis however, was found to be superior in detecting undislocated fractures in a cohort of patients with a high incidence of osteoporosis. Using MRI may be beneficial in select cases, especially when reduced bone density is suspected. Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. Preoperative Staging With 11C-Choline PET/CT Is Adequately Accurate in Patients With Very High-Risk Prostate Cancer.

    PubMed

    Schiavina, Riccardo; Bianchi, Lorenzo; Mineo Bianchi, Federico; Borghesi, Marco; Pultrone, Cristian Vincenzo; Dababneh, Hussam; Castellucci, Paolo; Ceci, Francesco; Nanni, Cristina; Gaudiano, Caterina; Fiorentino, Michelangelo; Porreca, Angelo; Chessa, Francesco; Minervini, Andrea; Fanti, Stefano; Brunocilla, Eugenio

    2018-05-30

    To evaluate the accuracy of 11 C-choline positron emission tomography (PET)/computed tomography (CT) for nodal staging of prostate cancer (PCa) in different populations of high-risk patients. We evaluated 262 individuals with intermediate- or high-risk PCa submitted to radical prostatectomy and extended pelvic lymph node dissection. Within men with high-risk disease, we identified a subgroup of individuals harboring very high-risk (VHR, n = 28) disease: clinical stage ≥ T2c and more than 5 cores with Gleason score 8-10; primary biopsy Gleason score of 5; 3 high-risk features; or prostate-specific antigen ≥ 30 ng/mL. The diagnostic accuracy of PET/CT and contrast-enhanced CT (CECT) was assessed after stratifying patients according to risk group classification on a patient- and anatomic region-based analysis. On patient-based analysis, considering high-risk patients (n = 155), 11 C-choline PET/CT versus CECT had sensitivity and specificity of 50% and 76% versus 21% and 92%, respectively. Considering VHR men as separate subgroups (n = 28), 11 C-choline PET/CT versus CECT had sensitivity and specificity of 71% and 93% versus 25% and 79%, respectively. Accordingly, in the VHR category, the area under the curve of 11 C-choline PET/CT versus CECT was 0.86 (95% confidence interval, 0.71-1.0) versus 0.69 (95% confidence interval, 0.52-0.86), respectively. On anatomic region-based analysis, considering the VHR group, 11 C-choline PET/CT versus CECT had sensitivity and specificity of 70.6% and 95.5% versus 35.3% and 98.5%, respectively. Patients with VHR characteristics could represent the ideal candidate to undergo disease staging with PET/CT before surgery with the highest cost efficacy. Copyright © 2018 Elsevier Inc. All rights reserved.

  20. Reduction of metal artifacts from hip prostheses on CT images of the pelvis: value of iterative reconstructions.

    PubMed

    Morsbach, Fabian; Bickelhaupt, Sebastian; Wanner, Guido A; Krauss, Andreas; Schmidt, Bernhard; Alkadhi, Hatem

    2013-07-01

    To assess the value of iterative frequency split-normalized (IFS) metal artifact reduction (MAR) for computed tomography (CT) of hip prostheses. This study had institutional review board and local ethics committee approval. First, a hip phantom with steel and titanium prostheses that had inlays of water, fat, and contrast media in the pelvis was used to optimize the IFS algorithm. Second, 41 consecutive patients with hip prostheses who were undergoing CT were included. Data sets were reconstructed with filtered back projection, the IFS algorithm, and a linear interpolation MAR algorithm. Two blinded, independent readers evaluated axial, coronal, and sagittal CT reformations for overall image quality, image quality of pelvic organs, and assessment of pelvic abnormalities. CT attenuation and image noise were measured. Statistical analysis included the Friedman test, Wilcoxon signed-rank test, and Levene test. Ex vivo experiments demonstrated an optimized IFS algorithm by using a threshold of 2200 HU with four iterations for both steel and titanium prostheses. Measurements of CT attenuation of the inlays were significantly (P < .001) more accurate for IFS when compared with filtered back projection. In patients, best overall and pelvic organ image quality was found in all reformations with IFS (P < .001). Pelvic abnormalities in 11 of 41 patients (27%) were diagnosed with significantly (P = .002) higher confidence on the basis of IFS images. CT attenuation of bladder (P < .001) and muscle (P = .043) was significantly less variable with IFS compared with filtered back projection and linear interpolation MAR. In comparison with that of FBP and linear interpolation MAR, noise with IFS was similar close to and far from the prosthesis (P = .295). The IFS algorithm for CT image reconstruction significantly reduces metal artifacts from hip prostheses, improves the reliability of CT number measurements, and improves the confidence for depicting pelvic abnormalities.

  1. Concurrent chemotherapy and pelvic radiation therapy compared with pelvic radiation therapy alone as adjuvant therapy after radical surgery in high-risk early-stage cancer of the cervix.

    PubMed

    Peters, W A; Liu, P Y; Barrett, R J; Stock, R J; Monk, B J; Berek, J S; Souhami, L; Grigsby, P; Gordon, W; Alberts, D S

    2000-04-01

    To determine whether the addition of cisplatin-based chemotherapy (CT) to pelvic radiation therapy (RT) will improve the survival of early-stage, high-risk patients with cervical carcinoma. Patients with clinical stage IA(2), IB, and IIA carcinoma of the cervix, initially treated with radical hysterectomy and pelvic lymphadenectomy, and who had positive pelvic lymph nodes and/or positive margins and/or microscopic involvement of the parametrium were eligible for this study. Patients were randomized to receive RT or RT + CT. Patients in each group received 49.3 GY RT in 29 fractions to a standard pelvic field. Chemotherapy consisted of bolus cisplatin 70 mg/m(2) and a 96-hour infusion of fluorouracil 1,000 mg/m(2)/d every 3 weeks for four cycles, with the first and second cycles given concurrent to RT. Between 1991 and 1996, 268 patients were entered onto the study. Two hundred forty-three patients were assessable (127 RT + CT patients and 116 RT patients). Progression-free and overall survival are significantly improved in the patients receiving CT. The hazard ratios for progression-free survival and overall survival in the RT only arm versus the RT + CT arm are 2.01 (P =.003) and 1.96 (P =. 007), respectively. The projected progression-free survivals at 4 years is 63% with RT and 80% with RT + CT. The projected overall survival rate at 4 years is 71% with RT and 81% with RT + CT. Grades 3 and 4 hematologic and gastrointestinal toxicity were more frequent in the RT + CT group. The addition of concurrent cisplatin-based CT to RT significantly improves progression-free and overall survival for high-risk, early-stage patients who undergo radical hysterectomy and pelvic lymphadenectomy for carcinoma of the cervix.

  2. SU-F-I-32: Organ Doses from Pediatric Head CT Scan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, H; Liu, Q; Qiu, J

    Purpose: To evaluate the organ doses of pediatric patients who undergoing head CT scan using Monte Carlo (MC) simulation and compare it with measurements in anthropomorphic child phantom.. Methods: A ten years old children voxel phantom was developed from CT images, the voxel size of the phantom was 2mm*2mm*2mm. Organ doses from head CT scan were simulated using MCNPX software, 180 detectors were placed in the voxel phantom to tally the doses of the represented tissues or organs. When performing the simulation, 120 kVp and 88 mA were selected as the scan parameters. The scan range covered from the topmore » of the head to the end of the chain, this protocol was used at CT simulator for radiotherapy. To validate the simulated results, organ doses were measured with radiophotoluminescence (RPL) detectors, placed in the 28 organs of the 10 years old CIRS ATOM phantom. Results: The organ doses results matched well between MC simulation and phantom measurements. The eyes dose was showed to be as expected the highest organ dose: 28.11 mGy by simulation and 27.34 mGy by measurement respectively. Doses for organs not included in the scan volume were much lower than those included in the scan volume, thymus doses were observed more than 10 mGy due the CT protocol for radiotherapy covered more body part than routine head CT scan. Conclusion: As the eyes are superficial organs, they may receive the highest radiation dose during the CT scan. Considering the relatively high radio sensitivity, using shielding material or organ based tube current modulation technique should be encouraged to reduce the eye radiation risks. Scan range was one of the most important factors that affects the organ doses during the CT scan. Use as short as reasonably possible scan range should be helpful to reduce the patient radiation dose. This work was supported by the National Natural Science Foundation of China(11475047)« less

  3. Shading correction algorithm for cone-beam CT in radiotherapy: extensive clinical validation of image quality improvement

    NASA Astrophysics Data System (ADS)

    Joshi, K. D.; Marchant, T. E.; Moore, C. J.

    2017-03-01

    A shading correction algorithm for the improvement of cone-beam CT (CBCT) images (Phys. Med. Biol. 53 5719{33) has been further developed, optimised and validated extensively using 135 clinical CBCT images of patients undergoing radiotherapy treatment of the pelvis, lungs and head and neck. An automated technique has been developed to efficiently analyse the large number of clinical images. Small regions of similar tissue (for example fat tissue) are automatically identified using CT images. The same regions on the corresponding CBCT image are analysed to ensure that they do not contain pixels representing multiple types of tissue. The mean value of all selected pixels and the non-uniformity, defined as the median absolute deviation of the mean values in each small region, are calculated. Comparisons between CT and raw and corrected CBCT images are then made. Analysis of fat regions in pelvis images shows an average difference in mean pixel value between CT and CBCT of 136:0 HU in raw CBCT images, which is reduced to 2:0 HU after the application of the shading correction algorithm. The average difference in non-uniformity of fat pixels is reduced from 33:7 in raw CBCT to 2:8 in shading-corrected CBCT images. Similar results are obtained in the analysis of lung and head and neck images.

  4. Three-dimensional computed tomographic volumetry precisely predicts the postoperative pulmonary function.

    PubMed

    Kobayashi, Keisuke; Saeki, Yusuke; Kitazawa, Shinsuke; Kobayashi, Naohiro; Kikuchi, Shinji; Goto, Yukinobu; Sakai, Mitsuaki; Sato, Yukio

    2017-11-01

    It is important to accurately predict the patient's postoperative pulmonary function. The aim of this study was to compare the accuracy of predictions of the postoperative residual pulmonary function obtained with three-dimensional computed tomographic (3D-CT) volumetry with that of predictions obtained with the conventional segment-counting method. Fifty-three patients scheduled to undergo lung cancer resection, pulmonary function tests, and computed tomography were enrolled in this study. The postoperative residual pulmonary function was predicted based on the segment-counting and 3D-CT volumetry methods. The predicted postoperative values were compared with the results of postoperative pulmonary function tests. Regarding the linear correlation coefficients between the predicted postoperative values and the measured values, those obtained using the 3D-CT volumetry method tended to be higher than those acquired using the segment-counting method. In addition, the variations between the predicted and measured values were smaller with the 3D-CT volumetry method than with the segment-counting method. These results were more obvious in COPD patients than in non-COPD patients. Our findings suggested that the 3D-CT volumetry was able to predict the residual pulmonary function more accurately than the segment-counting method, especially in patients with COPD. This method might lead to the selection of appropriate candidates for surgery among patients with a marginal pulmonary function.

  5. Prevalence of macular complications associated with high myopia by multimodal imaging.

    PubMed

    Lichtwitz, O; Boissonnot, M; Mercié, M; Ingrand, P; Leveziel, N

    2016-04-01

    To describe the prevalence of macular complications in patients with visual acuity decrease related to high myopia (HM). To establish correlations between these complications and demographic or anatomical characteristics. Cross-sectional observational study including HM patients undergoing best-corrected visual acuity (BCVA), fundus examination, macular SD-OCT, and fluorescein angiography in the case of suspicion of choroidal neovascularization (CNV). The presence of anatomical criteria (staphyloma, subfoveal choroidal thickness [CT]) and macular complications (CNV, lacquer cracks, central chorioretinal atrophy, dome-shaped macula with serous retinal detachment [SRD], retinal foveoschisis, macular hole and epiretinal membrane) was investigated. A total of 87 eyes of 47 patients were included (39 eyes without macular complication and 48 eyes with macular complications). In the case of macular complications, decrease in BCVA was related to CNV in 33%, macular hole in 25%, chorioretinal atrophy in 19%, foveoschisis in 11%, lacquer crack in 6%, to a dome-shape macula with serous retinal detachment in 4% and epiretinal membrane in 2%. After adjusting for interocular correlation and degree of myopia, staphyloma (P=0.0023), choroidal thinning (P=0.0036), and extrafoveal chorioretinal atrophy (P=0.042) were significantly associated with macular complications. High myopic patients with staphyloma or choroidal thinning should undergo regular comprehensive retinal screening for retinal complications. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  6. Cat-Scratch Disease: A Pitfall for Lymphoma Evaluation by FDG-PET/CT.

    PubMed

    Dubreuil, Julien; Dony, Arthur; Salles, Gilles; Traverse-Glehen, Alexandra; Giammarile, Francesco; Skanjeti, Andrea

    2017-02-01

    FDG-PET/CT is a standard of care in staging and response assessment of Hodgkin lymphoma. Hence, it is important to recognize pitfalls owing to the potential therapeutic impact. We report a case of a 29-year-old woman affected by stage III bulky Hodgkin lymphoma. The interim FDG-PET/CT showed a complete metabolic response. After three new cycles of chemotherapy, the patient showed fever and lymphadenopathy at clinic examination, PET/CT revealed several FDG uptakes at lymph nodes in inguinal and iliac region. Pathologic analyses, after biopsy and serologic examinations, led to the diagnosis of cat-scratch disease.

  7. [Usefulness of imaging examinations in preoperative diagnosis of acute appendicitis].

    PubMed

    Nitoń, Tomasz; Górecka-Nitoń, Aleksandra

    2014-01-01

    Acute appendicitis (AA) is the cause one of most operations perform in department of general surgery on emergency ward. Frequency of acute appendicitis range from 6-8% of population. Clinical presentation is frequently unspecified and despite common occurence leads to many difficulties in diagnosis. Diagnosis of acute appendicitis includes clinical examination, laboratory tests, diagnostic scoring systems, computer programs as physisian aids and imaging examinations. About 30-45% patients suspected of acute appendicitis have untypical clinical presentation and here use of US or CT is very helpful. Longstanding use of US resulted in high AA evaluation accuracy with high sensitivity (75-90%) and specificity (84-100%). CT demonstrates above 95% ratio of correct diagnoses, reduces negative appendectomy rates and perforation rates as well as unnecessary observations. CT sensitivity and specificity CT is estimated between 83-100% among different authors. Expedited AA diagnosis, surgery and reduced hospitalization time are possible advantages of imaging tests. Additionally these tests can detect alternative deseases imitating acute appnedicitis. Use of imaging tests especially CT is beneficial in fertile women because of frequent genito-urinary disorders leading to the most diagnostic errors. However thera are contraindications in use of CT, for example it can not be performed in early pregnancy etc...

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kruger, R.

    The US National Lung Screening Trial (NLST) was a multi-center randomized, controlled trial comparing a low-dose CT (LDCT) to posterior-anterior (PA) chest x-ray (CXR) in screening older, current and former heavy smokers for early detection of lung cancer. Recruitment was launched in September 2002 and ended in April 2004 when 53,454 participants had been randomized at 33 screening sites in equal proportions. Funded by the National Cancer Institute this trial demonstrated that LDCT screening reduced lung cancer mortality. The US Preventive Services Task Force (USPSTF) cited NLST findings and conclusions in its deliberations and analysis of lung cancer screening. Undermore » the 2010 Patient Protection and Affordable Care Act, the USPSTF favorable recommendation regarding lung cancer CT screening assisted in obtaining third-party payers coverage for screening. The objective of this session is to provide an introduction to the NLST and the trial findings, in addition to a comprehensive review of the dosimetry investigations and assessments completed using individual NLST participant CT and CXR examinations. Session presentations will review and discuss the findings of two independent assessments, a CXR assessment and the findings of a CT investigation calculating individual organ dosimetry values. The CXR assessment reviewed a total of 73,733 chest x-ray exams that were performed on 92 chest imaging systems of which 66,157 participant examinations were used. The CT organ dosimetry investigation collected scan parameters from 23,773 CT examinations; a subset of the 75,133 CT examinations performed using 97 multi-detector CT scanners. Organ dose conversion coefficients were calculated using a Monte Carlo code. An experimentally-validated CT scanner simulation was coupled with 193 adult hybrid computational phantoms representing the height and weight of the current U.S. population. The dose to selected organs was calculated using the organ dose library and the abstracted scan parameters. This session will review the results and summarize the individualized doses to major organs and the mean effective dose and CTDIvol estimate for 66,157 PA chest and 23,773 CT examinations respectively, using size-dependent computational phantoms coupled with Monte Carlo calculations. Learning Objectives: Review and summarize relevant NLST findings and conclusions. Understand the scope and scale of the NLST specific to participant dosimetry. Provide a comprehensive review of NLST participant dosimetry assessments. Summarize the results of an investigation providing individualized organ dose estimates for NLST participant cohorts.« less

  9. Temporal resolution and motion artifacts in single-source and dual-source cardiac CT.

    PubMed

    Schöndube, Harald; Allmendinger, Thomas; Stierstorfer, Karl; Bruder, Herbert; Flohr, Thomas

    2013-03-01

    The temporal resolution of a given image in cardiac computed tomography (CT) has so far mostly been determined from the amount of CT data employed for the reconstruction of that image. The purpose of this paper is to examine the applicability of such measures to the newly introduced modality of dual-source CT as well as to methods aiming to provide improved temporal resolution by means of an advanced image reconstruction algorithm. To provide a solid base for the examinations described in this paper, an extensive review of temporal resolution in conventional single-source CT is given first. Two different measures for assessing temporal resolution with respect to the amount of data involved are introduced, namely, either taking the full width at half maximum of the respective data weighting function (FWHM-TR) or the total width of the weighting function (total TR) as a base of the assessment. Image reconstruction using both a direct fan-beam filtered backprojection with Parker weighting as well as using a parallel-beam rebinning step are considered. The theory of assessing temporal resolution by means of the data involved is then extended to dual-source CT. Finally, three different advanced iterative reconstruction methods that all use the same input data are compared with respect to the resulting motion artifact level. For brevity and simplicity, the examinations are limited to two-dimensional data acquisition and reconstruction. However, all results and conclusions presented in this paper are also directly applicable to both circular and helical cone-beam CT. While the concept of total TR can directly be applied to dual-source CT, the definition of the FWHM of a weighting function needs to be slightly extended to be applicable to this modality. The three different advanced iterative reconstruction methods examined in this paper result in significantly different images with respect to their motion artifact level, despite exactly the same amount of data being used in the reconstruction process. The concept of assessing temporal resolution by means of the data employed for reconstruction can nicely be extended from single-source to dual-source CT. However, for advanced (possibly nonlinear iterative) reconstruction algorithms the examined approach fails to deliver accurate results. New methods and measures to assess the temporal resolution of CT images need to be developed to be able to accurately compare the performance of such algorithms.

  10. HIV-1 Envelope Glycoprotein Trafficking through the Endosomal Recycling Compartment Is Required for Particle Incorporation.

    PubMed

    Kirschman, Junghwa; Qi, Mingli; Ding, Lingmei; Hammonds, Jason; Dienger-Stambaugh, Krista; Wang, Jaang-Jiun; Lapierre, Lynne A; Goldenring, James R; Spearman, Paul

    2018-03-01

    The human immunodeficiency virus type 1 (HIV-1) envelope glycoprotein (Env) encodes specific trafficking signals within its long cytoplasmic tail (CT) that regulate incorporation into HIV-1 particles. Rab11-family interacting protein 1C (FIP1C) and Rab14 are host trafficking factors required for Env particle incorporation, suggesting that Env undergoes sorting from the endosomal recycling compartment (ERC) to the site of particle assembly on the plasma membrane. We disrupted outward sorting from the ERC by expressing a C-terminal fragment of FIP1C (FIP1C 560-649 ) and examined the consequences on Env trafficking and incorporation into particles. FIP1C 560-649 reduced cell surface levels of Env and prevented its incorporation into HIV-1 particles. Remarkably, Env was trapped in an exaggerated perinuclear ERC in a CT-dependent manner. Mutation of either the Yxxϕ endocytic motif or the YW 795 motif in the CT prevented Env trapping in the ERC and restored incorporation into particles. In contrast, simian immunodeficiency virus SIVmac239 Env was not retained in the ERC, while substitution of the HIV-1 CT for the SIV CT resulted in SIV Env retention in this compartment. These results provide the first direct evidence that Env traffics through the ERC and support a model whereby HIV-1 Env is specifically targeted to the ERC prior to FIP1C- and CT-dependent outward sorting to the particle assembly site on the plasma membrane. IMPORTANCE The HIV envelope protein is an essential component of the viral particle. While many aspects of envelope protein structure and function have been established, the pathway it follows in the cell prior to reaching the site of particle assembly is not well understood. The envelope protein has a very long cytoplasmic tail that interacts with the host cell trafficking machinery. Here, we utilized a truncated form of the trafficking adaptor FIP1C protein to arrest the intracellular transport of the envelope protein, demonstrating that it becomes trapped inside the cell within the endosomal recycling compartment. Intracellular trapping resulted in a loss of envelope protein on released particles and a corresponding loss of infectivity. Mutations of specific trafficking motifs in the envelope protein tail prevented its trapping in the recycling compartment. These results establish that trafficking to the endosomal recycling compartment is an essential step in HIV envelope protein particle incorporation. Copyright © 2018 American Society for Microbiology.

  11. Cumulative effective dose associated with computed tomography examinations in adolescent trauma patients.

    PubMed

    Choi, Seung Joon; Kim, Eun Young; Kim, Hyung Sik; Choi, Hye-Young; Cho, Jinseong; Yang, Hyuk Jun; Chung, Yong Eun

    2014-07-01

    The aims of this study were to analyze cumulative effective dose (cED) and to assess lifetime attributable risk (LAR) of cancer due to radiation exposure during computed tomography (CT) examinations in adolescent trauma patients. Between January 2010 and May 2011, the adolescent patients with trauma were enrolled in this study. Numbers of CT examinations and body regions examined were collated, and cEDs were calculated using dose-length product values and conversion factors. Lifetime attributable risk for cancer incidence and cancer-associated mortality were quantified based on the studies of survivors of the atomic bombs on Japan. Data were stratified according to severity of trauma: minor trauma, injury severity score of less than 16; and major trauma, injury severity score of 16 or greater. A total of 698 CT scans were obtained on the following regions of 484 adolescent patients: head CT, n = 647; rest of the body, n = 41; and thorax, n = 10. Mean cED per patient was 3.4 mSv, and mean LARs for cancer incidence and mortality were 0.05% and 0.02%, respectively. The majority of patients (98.4%) experienced minor trauma, and their mean cED and LARs for cancer incidence and mortality (3.0 mSv and 0.04% and 0.02%, respectively) were significantly lower than those of patients with major trauma (24.3 mSv and 0.31% and 0.15%, respectively, all P values < 0.001). The overall radiation-induced cancer risk due to CT examinations performed for the initial assessment of minor trauma was found to be relatively low in adolescent patients. However, adolescent patients with major trauma were exposed to a substantial amount of radiation during multiple CT examinations.

  12. TU-F-17A-06: Motion Stability and Dosimetric Impact of Spirometer-Based DIBH-RT of Left-Sided Breast Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McKenzie, E; Yang, W; Burnison, M

    2014-06-15

    Purpose: Patients undergoing radiotherapy (RT) for left-sided breast cancer have increased risk of coronary artery disease. Deep Inhalation Breath Hold assisted RT (DIBH-RT) is shown to increase the geometric separation of the target area and heart, reducing cardiac radiation dose. The purposes of this study are to use Cine MV portal images to determine the stability of spirometer-guided DIBH-RT and examine the dosimetric cardiopulmonary impact of this technique. Methods: Twenty consecutive patients with left-sided breast cancer were recruited to the IRB-approved study. Free-breathing (FB) and DIBH-CT's were acquired at simulation. Rigid registration of the FB-CT and DIBH-CT was performed usingmore » primarily breast tissue. Treatment plans were created for each FB-CT and DIBH-CT using identical paired tangent fields with field-in-field or electronic compensation techniques. Dosimetric evaluation included mean and maximum (Dmax) doses for the left anterior descending artery (LAD), mean heart dose, and left lung V20. Cine MV portal images were acquired for medial and lateral fields during treatment. Analysis of Cine images involved chest wall segmentation using an algorithm developed in-house. Intra- and inter-fractional chest wall motion were determined through affine registration to the first frame of each Cine. Results: Dose to each cardiac structure evaluated was significantly (p<0.001) reduced with the DIBH plans. Mean heart dose decreased from 2.9(0.9–6.6) to 1.6(0.6–5.3) Gy; mean LAD dose from 16.6(3–43.6) to 7.4(1.7–32.7) Gy; and LAD Dmax from 35.4 (6.1–53) to 18.4(2.5–51.2) Gy. No statistically significant reduction was found for the left lung V20. Average AP and SI median chest wall motion (intrafractional) was 0.1 (SD=0.9) and 0.5 (SD=1.1) mm, respectively. Average AP inter-fractional chest wall motion was 2.0 (SD=1.4) mm. Conclusion: Spirometer-based DIBH treatments of the left breast are reproducible both inter- and intra-fractionally, and provide a statistically and potentially clinically useful dosimetric advantage to cardiac structures.« less

  13. Did low tube voltage CT combined with low contrast media burden protocols accomplish the goal of "double low" for patients? An overview of applications in vessels and abdominal parenchymal organs over the past 5 years.

    PubMed

    Shen, Yaqi; Hu, Xuemei; Zou, Xianlun; Zhu, Di; Li, Zhen; Hu, Daoyu

    2016-09-01

    Imaging communities have already reached a consensus that the radiation dose of computed tomography (CT) should be reduced as much as reasonably achievable to lower population risks. Increasing attention is being paid to iodinated contrast media (CM) induced nephrotoxicity (CIN); a decrease in the intake of iodinated CM is required by increasingly more radiologists. Theoretically, the radiation dose varies with the tube current time and square of the tube voltage, with higher iodine contrast at low photon energies (Huda et al. [2000] Radiology, 21 7, 430-435).The use of low tube voltage is a promising strategy to reduce both the radiation dose and CM burden. The term 'double low' has been coined to describe scanning protocols that reduce radiation dose and iodine intake synchronously. These protocols are becoming increasingly popular in the clinical setting. The aim of this review was to describe all original studies using the 'double low' strategy in the last 5 years. We searched an online electronic database (PubMed) from January 2011 to December 2015 for original studies published on the relationship of low tube voltage with low radiation dose and low iodine contrast media burden in patients undergoing CT scans. Studies that failed to reduce radiation dose or iodine CM burden were excluded in this study. Thirty-seven studies aimed at reducing radiation dose using low tube voltage combined with iodine CM reduced protocols were included in this study. Most studies evaluated conditions associated with arteries. Four were cerebral and neck computed tomography angiography (CTA) studies, 15 were pulmonary CTA (pCTA) and coronary CTA (cCTA) studies, one concerned myocardial perfusion, five studies focused on the thoracic and abdominal aorta, and one investigated renal arteries. Three studies consisted of CT venography (CTV) of the pelvis and lower extremities. Six publications examined the liver, and two focused on the kidney. Overall, this review demonstrates that the low tube voltage CT protocol is a powerful tool to reduce the radiation dose in CTA, especially with pCTA and cCTA. © 2016 John Wiley & Sons Ltd.

  14. The course of cancer related fatigue up to ten years in early breast cancer patients: What impact in clinical practice?

    PubMed

    Fabi, Alessandra; Falcicchio, Chiara; Giannarelli, Diana; Maggi, Gabriella; Cognetti, Francesco; Pugliese, Patrizia

    2017-08-01

    Little is known about the cancer related fatigue (CRF) along cancer course and risk factors that could predict CRF development and persistence in breast cancer (BC) survivors. This prospective study detected incidence, timing of onset, duration of CRF, impact on QoL and psychological distress. Seventy-eight early BC patients, undergoing chemotherapy (CT) followed or not by hormonal therapy were assessed for QoL and psychological distress by EORTC QLQC30 and HADs questionnaires. Fatigue was investigated with mix methods, structured interview and psychometric measures. A qualitative analysis was added to assess the behavioral pattern of CRF. Low fatigue levels were identified after surgery (9%), increasing during (49%) and at the end of CT (47%), maintaining after 1 year (31%) and declining up to ten years of follow-up. Prevalence of CRF was higher at the end of CT and lower at follow-up. At the end and after 1 and 2 years from CT, persistence of CRF was associated to anxiety in 20%, 11% and 5% and to depression in 15%, 10% and 5% respectively. A relationship between CRF and psychological distress was observed; patients presenting depression and anxiety before CT were at higher risk for fatigue onset at a later period. A relationship between fatigue and QoL was noted at the end of CT. Our study shows the fatigue timely trend in early BC patients from surgery, CT and follow-up. Identification of biological, psychological, social predictor factors related to fatigue could be helpful for early interventions in patients at higher risk of developing fatigue. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  15. Deformable registration of CT and cone-beam CT with local intensity matching.

    PubMed

    Park, Seyoun; Plishker, William; Quon, Harry; Wong, John; Shekhar, Raj; Lee, Junghoon

    2017-02-07

    Cone-beam CT (CBCT) is a widely used intra-operative imaging modality in image-guided radiotherapy and surgery. A short scan followed by a filtered-backprojection is typically used for CBCT reconstruction. While data on the mid-plane (plane of source-detector rotation) is complete, off-mid-planes undergo different information deficiency and the computed reconstructions are approximate. This causes different reconstruction artifacts at off-mid-planes depending on slice locations, and therefore impedes accurate registration between CT and CBCT. In this paper, we propose a method to accurately register CT and CBCT by iteratively matching local CT and CBCT intensities. We correct CBCT intensities by matching local intensity histograms slice by slice in conjunction with intensity-based deformable registration. The correction-registration steps are repeated in an alternating way until the result image converges. We integrate the intensity matching into three different deformable registration methods, B-spline, demons, and optical flow that are widely used for CT-CBCT registration. All three registration methods were implemented on a graphics processing unit for efficient parallel computation. We tested the proposed methods on twenty five head and neck cancer cases and compared the performance with state-of-the-art registration methods. Normalized cross correlation (NCC), structural similarity index (SSIM), and target registration error (TRE) were computed to evaluate the registration performance. Our method produced overall NCC of 0.96, SSIM of 0.94, and TRE of 2.26 → 2.27 mm, outperforming existing methods by 9%, 12%, and 27%, respectively. Experimental results also show that our method performs consistently and is more accurate than existing algorithms, and also computationally efficient.

  16. Deformable registration of CT and cone-beam CT with local intensity matching

    NASA Astrophysics Data System (ADS)

    Park, Seyoun; Plishker, William; Quon, Harry; Wong, John; Shekhar, Raj; Lee, Junghoon

    2017-02-01

    Cone-beam CT (CBCT) is a widely used intra-operative imaging modality in image-guided radiotherapy and surgery. A short scan followed by a filtered-backprojection is typically used for CBCT reconstruction. While data on the mid-plane (plane of source-detector rotation) is complete, off-mid-planes undergo different information deficiency and the computed reconstructions are approximate. This causes different reconstruction artifacts at off-mid-planes depending on slice locations, and therefore impedes accurate registration between CT and CBCT. In this paper, we propose a method to accurately register CT and CBCT by iteratively matching local CT and CBCT intensities. We correct CBCT intensities by matching local intensity histograms slice by slice in conjunction with intensity-based deformable registration. The correction-registration steps are repeated in an alternating way until the result image converges. We integrate the intensity matching into three different deformable registration methods, B-spline, demons, and optical flow that are widely used for CT-CBCT registration. All three registration methods were implemented on a graphics processing unit for efficient parallel computation. We tested the proposed methods on twenty five head and neck cancer cases and compared the performance with state-of-the-art registration methods. Normalized cross correlation (NCC), structural similarity index (SSIM), and target registration error (TRE) were computed to evaluate the registration performance. Our method produced overall NCC of 0.96, SSIM of 0.94, and TRE of 2.26 → 2.27 mm, outperforming existing methods by 9%, 12%, and 27%, respectively. Experimental results also show that our method performs consistently and is more accurate than existing algorithms, and also computationally efficient.

  17. The cost-effectiveness of cardiac computed tomography for patients with stable chest pain.

    PubMed

    Agus, A M; McKavanagh, P; Lusk, L; Verghis, R M; Walls, G M; Ball, P A; Trinick, T R; Harbinson, M T; Donnelly, P M

    2016-03-01

    To assess the cost-effectiveness of cardiac CT compared with exercise stress testing (EST) in improving the health-related quality of life of patients with stable chest pain. A cost-utility analysis alongside a single-centre randomised controlled trial carried out in Northern Ireland. Patients with stable chest pain were randomised to undergo either cardiac CT assessment or EST (standard care). The main outcome measure was cost per quality adjusted life year (QALY) gained at 1 year. Of the 500 patients recruited, 250 were randomised to cardiac CT and 250 were randomised to EST. Cardiac CT was the dominant strategy as it was both less costly (incremental total costs -£50.45; 95% CI -£672.26 to £571.36) and more effective (incremental QALYs 0.02; 95% CI -0.02 to 0.05) than EST. At a willingness-to-pay threshold of £20 000 per QALY the probability of cardiac CT being cost-effective was 83%. Subgroup analyses indicated that cardiac CT appears to be most cost-effective in patients with a likelihood of coronary artery disease (CAD) of <30%, followed by 30%-60% and then >60%. Cardiac CT is cost-effective compared with EST and cost-effectiveness was observed to vary with likelihood of CAD. This finding could have major implications for how patients with chest pain in the UK are assessed, however it would need to be validated in other healthcare systems. (ISRCTN52480460); results. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  18. Can Fan-Beam Interactive Computed Tomography Accurately Predict Indirect Decompression in Minimally Invasive Spine Surgery Fusion Procedures?

    PubMed

    Janssen, Insa; Lang, Gernot; Navarro-Ramirez, Rodrigo; Jada, Ajit; Berlin, Connor; Hilis, Aaron; Zubkov, Micaella; Gandevia, Lena; Härtl, Roger

    2017-11-01

    Recently, novel mobile intraoperative fan-beam computed tomography (CT) was introduced, allowing for real-time navigation and immediate intraoperative evaluation of neural decompression in spine surgery. This study sought to investigate whether intraoperatively assessed neural decompression during minimally invasive spine surgery (MISS) has a predictive value for clinical and radiographic outcome. A retrospective study of patients undergoing intraoperative CT (iCT)-guided extreme lateral interbody fusion or transforaminal lumbar interbody fusion was conducted. 1) Preoperative, 2) intraoperative (after cage implantation, 3) postoperative, and 4) follow-up radiographic and clinical parameters obtained from radiography or CT were quantified. Thirty-four patients (41 spinal segments) were analyzed. iCT-based navigation was successfully accomplished in all patients. Radiographic parameters showed significant improvement from preoperatively to intraoperatively after cage implantation in both MISS procedures (extreme lateral interbody fusion/transforaminal lumbar interbody fusion) (P ≤ 0.05). Radiologic parameters for both MISS fusion procedures did not show significant differences to the assessed radiographic measures at follow-up (P > 0.05). Radiologic outcome values did not decrease when compared intraoperatively (after cage implantation) to latest follow-up. Intraoperative fan-beam CT is capable of assessing neural decompression intraoperatively with high accuracy, allowing for precise prediction of radiologic outcome and earliest possible feedback during MISS fusion procedures. These findings are highly valuable for routine practice and future investigations toward finding a threshold for neural decompression that translates into clinical improvement. If sufficient neural decompression has been confirmed with iCT imaging studies, additional postoperative and/or follow-up imaging studies might no longer be required if patients remain asymptomatic. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Computed tomography (CT)-compatible remote center of motion needle steering robot: Fusing CT images and electromagnetic sensor data.

    PubMed

    Shahriari, Navid; Heerink, Wout; van Katwijk, Tim; Hekman, Edsko; Oudkerk, Matthijs; Misra, Sarthak

    2017-07-01

    Lung cancer is the most common cause of cancer-related death, and early detection can reduce the mortality rate. Patients with lung nodules greater than 10 mm usually undergo a computed tomography (CT)-guided biopsy. However, aligning the needle with the target is difficult and the needle tends to deflect from a straight path. In this work, we present a CT-compatible robotic system, which can both position the needle at the puncture point and also insert and rotate the needle. The robot has a remote-center-of-motion arm which is achieved through a parallel mechanism. A new needle steering scheme is also developed where CT images are fused with electromagnetic (EM) sensor data using an unscented Kalman filter. The data fusion allows us to steer the needle using the real-time EM tracker data. The robot design and the steering scheme are validated using three experimental cases. Experimental Case I and II evaluate the accuracy and CT-compatibility of the robot arm, respectively. In experimental Case III, the needle is steered towards 5 real targets embedded in an anthropomorphic gelatin phantom of the thorax. The mean targeting error for the 5 experiments is 1.78 ± 0.70 mm. The proposed robotic system is shown to be CT-compatible with low targeting error. Small nodule size and large needle diameter are two risk factors that can lead to complications in lung biopsy. Our results suggest that nodules larger than 5 mm in diameter can be targeted using our method which may result in lower complication rate. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  20. Does the time between CT scan and chemotherapy increase the risk of acute adverse reactions to iodinated contrast media in cancer patients?

    PubMed

    Farolfi, Alberto; Carretta, Elisa; Luna, Corradina Della; Ragazzini, Angela; Gentili, Nicola; Casadei, Carla; Barone, Domenico; Minguzzi, Martina; Amadori, Dino; Nanni, Oriana; Gavelli, Giampaolo

    2014-10-31

    Cancer patients undergo routine computed-tomography (CT) scans and, therefore, iodinated contrast media (ICM) administration. It is not known whether a time-dependent correlation exists between chemotherapy administration, contrast enhanced CT and onset of acute ICM-related adverse reactions (ARs). All consecutive contrast-enhanced CTs performed from 1 January 2010 to 31 December 2012 within 30 days of the last chemotherapy administration were retrospectively reviewed. Episodes of acute ICM-related ARs were reported to the pharmacovigilance officer. We analyzed time to CT evaluation calculated as the time elapsed from the date of the CT performed to the date of the last chemotherapy administration. Patients were classified into 4 groups based on the antineoplastic treatment: platinum-based, taxane-based, platinum plus taxane and other group. Out of 10,472 contrast-enhanced CTs performed, 3,945 carried out on 1,878 patients were considered for the study. Forty acute ICM-related ARs (1.01%; 95% CI, 0.70-1.33) were reported. No differences were seen among immediate (within 10 days of the last chemotherapy administration), early (11-20 days) and delayed (21-30 days) CTs. Median time to CT in patients who experienced an acute ICM-related AR by treatment group was not statistically different: 20 days (range 6-30), 17 days (range 5-22), 13 days (range 8-17), 13 days (range (2-29) for the platinum, taxane, platinum plus taxane and other group, respectively (P =0.251). Our results did not reveal any correlation between time to CT and risk of acute ICM-related ARs in cancer patients.

  1. Predictors of idiopathic pulmonary fibrosis in absence of radiologic honeycombing: A cross sectional analysis in ILD patients undergoing lung tissue sampling.

    PubMed

    Salisbury, Margaret L; Xia, Meng; Murray, Susan; Bartholmai, Brian J; Kazerooni, Ella A; Meldrum, Catherine A; Martinez, Fernando J; Flaherty, Kevin R

    2016-09-01

    Idiopathic pulmonary fibrosis (IPF) can be diagnosed confidently and non-invasively when clinical and computed tomography (CT) criteria are met. Many do not meet these criteria due to absence of CT honeycombing. We investigated predictors of IPF and combinations allowing accurate diagnosis in individuals without honeycombing. We utilized prospectively collected clinical and CT data from patients enrolled in the Lung Tissue Research Consortium. Included patients had no honeycombing, no connective tissue disease, underwent diagnostic lung biopsy, and had CT pattern consistent with fibrosing ILD (n = 200). Logistic regression identified clinical and CT variables predictive of IPF. The probability of IPF was assessed at various cut-points of important clinical and CT variables. A multivariable model adjusted for age and gender found increasingly extensive reticular densities (OR 2.93, CI 95% 1.55-5.56, p = 0.001) predicted IPF, while increasing ground glass densities predicted a diagnosis other than IPF (OR 0.55, CI 95% 0.34-0.89, p = 0.02). The model-based probability of IPF was 80% or greater in patients with age at least 60 years and extent of reticular density one-third or more of total lung volume; for patients meeting or exceeding these clinical thresholds the specificity for IPF is 96% (CI 95% 91-100%) with 21 of 134 (16%) biopsies avoided. In patients with suspected fibrotic ILD and absence of CT honeycombing, extent of reticular and ground glass densities predict a diagnosis of IPF. The probability of IPF exceeds 80% in subjects over age 60 years with one-third of total lung having reticular densities. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Comparison of onboard low-field magnetic resonance imaging versus onboard computed tomography for anatomy visualization in radiotherapy.

    PubMed

    Noel, Camille E; Parikh, Parag J; Spencer, Christopher R; Green, Olga L; Hu, Yanle; Mutic, Sasa; Olsen, Jeffrey R

    2015-01-01

    Onboard magnetic resonance imaging (OB-MRI) for daily localization and adaptive radiotherapy has been under development by several groups. However, no clinical studies have evaluated whether OB-MRI improves visualization of the target and organs at risk (OARs) compared to standard onboard computed tomography (OB-CT). This study compared visualization of patient anatomy on images acquired on the MRI-(60)Co ViewRay system to those acquired with OB-CT. Fourteen patients enrolled on a protocol approved by the Institutional Review Board (IRB) and undergoing image-guided radiotherapy for cancer in the thorax (n = 2), pelvis (n = 6), abdomen (n = 3) or head and neck (n = 3) were imaged with OB-MRI and OB-CT. For each of the 14 patients, the OB-MRI and OB-CT datasets were displayed side-by-side and independently reviewed by three radiation oncologists. Each physician was asked to evaluate which dataset offered better visualization of the target and OARs. A quantitative contouring study was performed on two abdominal patients to assess if OB-MRI could offer improved inter-observer segmentation agreement for adaptive planning. In total 221 OARs and 10 targets were compared for visualization on OB-MRI and OB-CT by each of the three physicians. The majority of physicians (two or more) evaluated visualization on MRI as better for 71% of structures, worse for 10% of structures, and equivalent for 14% of structures. 5% of structures were not visible on either. Physicians agreed unanimously for 74% and in majority for > 99% of structures. Targets were better visualized on MRI in 4/10 cases, and never on OB-CT. Low-field MR provides better anatomic visualization of many radiotherapy targets and most OARs as compared to OB-CT. Further studies with OB-MRI should be pursued.

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ng, Sweet Ping, E-mail: sweet.ng@petermac.org; David, Steven; Alamgeer, Muhammad

    Purpose: To assess the diagnostic performance of pretreatment {sup 18}F-fluorodeoxyglucose positron emission tomography/computed tomography ({sup 18}F-FDG PET/CT) and its impact on radiation therapy treatment decisions in patients with locally advanced breast cancer (LABC). Methods and Materials: Patients with LABC with Eastern Cooperative Oncology Group performance status <2 and no contraindication to neoadjuvant chemotherapy, surgery, and adjuvant radiation therapy were enrolled on a prospective trial. All patients had pretreatment conventional imaging (CI) performed, including bilateral breast mammography and ultrasound, bone scan, and CT chest, abdomen, and pelvis scans performed. Informed consent was obtained before enrolment. Pretreatment whole-body {sup 18}F-FDG PET/CT scansmore » were performed on all patients, and results were compared with CI findings. Results: A total of 154 patients with LABC with no clinical or radiologic evidence of distant metastases on CI were enrolled. Median age was 49 years (range, 26-70 years). Imaging with PET/CT detected distant metastatic disease and/or locoregional disease not visualized on CI in 32 patients (20.8%). Distant metastatic disease was detected in 17 patients (11.0%): 6 had bony metastases, 5 had intrathoracic metastases (pulmonary/mediastinal), 2 had distant nodal metastases, 2 had liver metastases, 1 had pulmonary and bony metastases, and 1 had mediastinal and distant nodal metastases. Of the remaining 139 patients, nodal disease outside conventional radiation therapy fields was detected on PET/CT in 15 patients (10.8%), with involvement of ipsilateral internal mammary nodes in 13 and ipsilateral level 5 cervical nodes in 2. Conclusions: Imaging with PET/CT provides superior diagnostic and staging information in patients with LABC compared with CI, which has significant therapeutic implications with respect to radiation therapy management. Imaging with PET/CT should be considered in all patients undergoing primary staging for LABC.« less

  4. Incidence and location of lymph node metastases in patients undergoing radical cystectomy for clinical non-muscle invasive bladder cancer: results from a prospective lymph node mapping study.

    PubMed

    Bruins, Harman M; Skinner, Eila C; Dorin, Ryan P; Ahmadi, Hamed; Djaladat, Hooman; Miranda, Gus; Cai, Jie; Daneshmand, Siamak

    2014-01-01

    The objective of this study is to investigate the incidence and location of lymph node metastases (LNMs) in patients undergoing radical cystectomy (RC) and lymph node dissection (LND) for clinical non-muscle invasive bladder cancer (NMIBC). Prospectively collected data of 637 patients who underwent RC and 'superextended' LND with intent-to-cure for urothelial carcinoma of the bladder between 2002 and 2008 were examined. Inclusion criteria were (a) clinical stage Ta, Tis-only, or T1, (b) muscle presence at diagnostic transurethral resection in clinical T1 patients, (c) no prior diagnosis of ≥ T2 disease, (d) no neoadjuvant therapy, and (e) lymphatic tissue sample submitted from all 13 predesignated locations. Lymph node mapping was performed in all patients to determine the location of metastatic lymph nodes. Median follow-up time was 4.7 years. Recurrence-free survival and overall survival were reported. A total of 114 patients were included of whom 9 patients (7.9%) had LNM. Stratified by clinical stage, LNM was present in 6/67 (9.0%) patients with cT1, 3/25 (12.0%) patients with cTis-only, and none of the 22 patients with cTa. Of the 9 node-positive patients (33.3%), 3 had LNM proximal to the aortic bifurcation. No skip metastases were found. After RC, 27 patients (23.7%) were upstaged to muscle invasive disease; of whom 16.7% had cT1, 2.6% had cTa, and 4.4% had cTis-only. Of the remaining 87 patients with pathologic NMIBC, 1 patient (1.1%) had LNM, limited to the true pelvis. Five-year RFS was 82.3%, 81.5%, and 62.0% in patients with pathologic NMIBC, clinical NMIBC, and pathologic muscle invasive bladder cancer, respectively. Routine LND is important in patients with cT1 and cTis-only bladder cancer, but may have limited value in patients with cTa. LNM beyond the boundaries of a standard LND occurred in up to one-third of node-positive patients. In the absence of skip metastases, however, performing a standard LND would correctly identify all node-positive patients. Whether removal of LNM proximal to the common iliac vessels provides a survival benefit remains to be evaluated in future prospective studies. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. WE-B-207-00: CT Lung Cancer Screening Part 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    2015-06-15

    The US National Lung Screening Trial (NLST) was a multi-center randomized, controlled trial comparing a low-dose CT (LDCT) to posterior-anterior (PA) chest x-ray (CXR) in screening older, current and former heavy smokers for early detection of lung cancer. Recruitment was launched in September 2002 and ended in April 2004 when 53,454 participants had been randomized at 33 screening sites in equal proportions. Funded by the National Cancer Institute this trial demonstrated that LDCT screening reduced lung cancer mortality. The US Preventive Services Task Force (USPSTF) cited NLST findings and conclusions in its deliberations and analysis of lung cancer screening. Undermore » the 2010 Patient Protection and Affordable Care Act, the USPSTF favorable recommendation regarding lung cancer CT screening assisted in obtaining third-party payers coverage for screening. The objective of this session is to provide an introduction to the NLST and the trial findings, in addition to a comprehensive review of the dosimetry investigations and assessments completed using individual NLST participant CT and CXR examinations. Session presentations will review and discuss the findings of two independent assessments, a CXR assessment and the findings of a CT investigation calculating individual organ dosimetry values. The CXR assessment reviewed a total of 73,733 chest x-ray exams that were performed on 92 chest imaging systems of which 66,157 participant examinations were used. The CT organ dosimetry investigation collected scan parameters from 23,773 CT examinations; a subset of the 75,133 CT examinations performed using 97 multi-detector CT scanners. Organ dose conversion coefficients were calculated using a Monte Carlo code. An experimentally-validated CT scanner simulation was coupled with 193 adult hybrid computational phantoms representing the height and weight of the current U.S. population. The dose to selected organs was calculated using the organ dose library and the abstracted scan parameters. This session will review the results and summarize the individualized doses to major organs and the mean effective dose and CTDIvol estimate for 66,157 PA chest and 23,773 CT examinations respectively, using size-dependent computational phantoms coupled with Monte Carlo calculations. Learning Objectives: Review and summarize relevant NLST findings and conclusions. Understand the scope and scale of the NLST specific to participant dosimetry. Provide a comprehensive review of NLST participant dosimetry assessments. Summarize the results of an investigation providing individualized organ dose estimates for NLST participant cohorts.« less

  6. [Comparative evaluation of ultrasonography, computerized tomography, angiography and lipiodol CT in defining extent of hepatocarcinoma. A multicenter study].

    PubMed

    Dalla Palma, L; Pozzi Mucelli, R; Sponza, M; Bartolozzi, C; De Santis, M; Gandini, G; Mannella, P; Matricardi, L; Rossi, C; Simonetti, G

    1995-03-01

    The authors report the results of a multicentric trial on hepatocellular carcinoma (HCC) patients, whose lesions were confirmed with biopsy or by high (> 400 ng/ml) alpha-fetoprotein levels. The series consisted of 149 patients examined in 8 different centers and submitted to ultrasonography (US), Computed Tomography (CT) before and after contrast agent administration, angiography and Lipiodol CT. According to lesion size and number, the patients were divided with each imaging modality into three groups: a) group 1: unifocal HCC < 5 cm diameter; b) group 2: multifocal HCC with 2-3 nodules and/or tumor mass < 80 ml; c) multifocal HCC with more than 3 nodules (with total tumor mass not exceeding 40% of liver volume) or with total tumor mass > 80 ml. In 77 patients all the examinations were available for comparison. US and CT diagnosed more patients as belonging to group 1 than angiography and Lipiodol CT, while more patients were classified as groups 2 and 3 with angiography and Lipiodol CT, meaning that US and CT may understage some HCC cases (about 15%) because they show a lower number of nodules. This observation was confirmed by the direct comparison between US and Lipiodol CT (in 114 patients), CT and Lipiodol CT (in 103 patients) and angiography and Lipiodol CT (in 116 patients). US and Lipiodol CT were in disagreement in 18 cases, CT and Lipiodol CT in 16 cases and angiography and Lipiodol CT in 13 cases. In most of these cases, Lipiodol CT showed more lesions than the other techniques. The size of the undetected lesions was small, ranging few mm to 2 cm in nearly all cases. To conclude, the results of this multicentric trial show that Lipiodol CT is a fundamental tool to evaluate HCC extent. In contrast, conventional CT appeared not to add any significant piece of information and can therefore be excluded from the diagnostic protocol of HCC.

  7. Reasons for testing women for genital Chlamydia trachomatis infection in the Calgary region

    PubMed Central

    Church, Deirdre L; Zentner, Ali; Semeniuk, Heather; Henderson, Elizabeth; Read, Ron

    2003-01-01

    OBJECTIVE: To determine the clinical reason(s) for screening women with varying degrees of risk for genital Chlamydia trachomatis (CT) in the Calgary region. DESIGN: Women aged 15 to 75 years were enrolled at various patient care locations. Pertinent risk factors for genital CT infection were recorded and a gynecological examination was performed. Two endocervical swabs and a first-void urine sample were collected for CT detection using two different nucleic acid amplification test methods. SETTING: Calgary is an urban region that provides healthcare services to a population of almost one million people. Microbiology services are provided by Calgary Laboratory Services through a centralized regional laboratory service. MAIN RESULTS: 504 women with a mean age of 28.1 ±SD 8.22 years were enrolled. Two hundred ninety-one women (57.8%) were at high risk for acquiring genital CT infection. Twenty-eight (5.6%) tested positive for CT infection and almost all of these women (26 of 28, 93%) had risk factors for acquiring infection. Of the high-risk women, 9.8% were CT positive versus only 1.3% of women at low risk (P=0.0001). Only two of 152 (1.3%) women older than 30 years had genital CT infections. Although most women were asymptomatic, those with laboratory-confirmed CT infection were more likely to have genitourinary symptoms. Three hundred forty-three of 476 (72%) women who did not have genital CT infection had no risk factors, and screening was done as part of a routine gynecological examination for other purposes (prenatal visit, Pap smear). CONCLUSION: Women without risk factors are being screened routinely for genital CT infection as part of a routine gynecological examination done for other reasons. Elimination of the routine screening of low-risk women older than 30 years of age would decrease the current regional utilization of CT tests by as much as one-third. PMID:18159423

  8. Computerized method for automatic evaluation of lean body mass from PET/CT: comparison with predictive equations.

    PubMed

    Chan, Tao

    2012-01-01

    CT has become an established method for calculating body composition, but it requires data from the whole body, which are not typically obtained in routine PET/CT examinations. A computerized scheme that evaluates whole-body lean body mass (LBM) based on CT data from limited-whole-body coverage was developed. The LBM so obtained was compared with results from conventional predictive equations. LBM can be obtained automatically from limited-whole-body CT data by 3 means: quantification of body composition from CT images in the limited-whole-body scan, based on thresholding of CT attenuation; determination of the range of coverage based on a characteristic trend of changing composition across different levels and pattern recognition of specific features at strategic positions; and estimation of the LBM of the whole body on the basis of a predetermined relationship between proportion of fat mass and extent of coverage. This scheme was validated using 18 whole-body PET/CT examinations truncated at different lengths to emulate limited-whole-body data. LBM was also calculated using predictive equations that had been reported for use in SUV normalization. LBM derived from limited-whole-body data using the proposed method correlated strongly with LBM derived from whole-body CT data, with correlation coefficients ranging from 0.991 (shorter coverage) to 0.998 (longer coverage) and SEMs of LBM ranging from 0.14 to 0.33 kg. These were more accurate than results from different predictive equations, which ranged in correlation coefficient from 0.635 to 0.970 and in SEM from 0.64 to 2.40 kg. LBM of the whole body could be automatically estimated from CT data of limited-whole-body coverage typically acquired in PET/CT examinations. This estimation allows more accurate and consistent quantification of metabolic activity of tumors based on LBM-normalized standardized uptake value.

  9. A case of severe sepsis presenting marked decrease of neutrophils and interesting findings on dynamic CT.

    PubMed

    Makino, Isamu; Tajima, Hidehiro; Kitagawa, Hirohisa; Nakagawara, Hisatoshi; Miyashita, Tomoharu; Nakanuma, Shinichi; Hayashi, Hironori; Takamura, Hiroyuki; Fushida, Sachio; Ohta, Tetsuo

    2015-05-28

    In a patient with severe sepsis, we sometimes observe immediate decrease of the counts of white blood cells (WBCs) and neutrophils, which is known as an indicator for poor prognosis. We observed marked decrease of white blood cells and neutrophils on blood examination and interesting findings on dynamic CT. Here, we present the case of a patient with severe postoperative sepsis occurring after major abdominal surgery and we discuss the mechanism of such clinical presentations. A 60-year-old man received pancreatoduodenectomy with colectomy for pancreatic cancer. He developed a high fever on postoperative day 3. We observed marked decrease of WBCs and neutrophils on blood examination. We also observed slight swelling of the liver, inhomogeneous enhancement of liver parenchyma in arterial phase, and periportal low density in the Glisson capsule in portal phase, without any findings indicating infectious complications on dynamic CT. WBCs and neutrophils increased above normal range in just 6 hours. Blood culture examination performed while the patient had a high fever was positive for Aeromonas hydrophila. After receiving intensive care, he promptly recovered from severe sepsis. The CT findings disappeared on second dynamic CT examination performed 3 days after the first examination. We treated a patient with severe sepsis after major abdominal surgery who presented very rapid change of the counts of WBCs and neutrophils and interesting CT findings in the liver. We rescued him from a critical situation by prompt and intensive treatment. Research is needed to accumulate and analyze data from more patients who present a similar clinical course to better understand their pathophysiological conditions.

  10. Treatment complexity: a description of chemotherapy and supportive care treatment visits in patients with advanced-stage cancer diagnoses.

    PubMed

    Sumpio, Catherine; Knobf, M Tish; Jeon, Sangchoon

    2016-01-01

    Modern chemotherapy regimens are growing increasingly complex, involving lengthy outpatient infusions, and additional visits for supportive care. The treatment of advanced-stage patients is uniquely one of unremitting therapy and varying complexity. The study's purpose was to describe and quantify the dimensions of treatment complexity in terms of chemotherapy (CT) and supportive care (SC) visits. Electronic medical records for 121 subjects with stages III and IV cancer were reviewed. Visits were classified as SC and CT types, and actual hours and visit numbers were calculated for a 3-month treatment period. Analysis included descriptive and generalized linear modeling statistics. Subjects ≥65 years spent fewer total hours (M = 18.17 h, SD = 10.17 h, p = 0.04), but experienced more total visits (M = 10.96 visits, SD = 4.65 visits, p = 0.02) than younger subjects. More than 71% of younger patients spent two or more hours per chemotherapy visit, compared to 41.7% of older patients (p = 0.001). Older subjects were more likely to have a SC visit (p = 0.03), but did not differ from younger subjects in SC visit numbers (p = 0.3) or hours (p = 0.6). Females averaged 3.81 more total hours (M = 22. 61 h, SD = 11.06 h, p = 0.055) and had more total visits (M = 10.80 visits, SD = 3.71, p = 0.02) than males. By visit type, women spent twice the hours undergoing SC than males (M = 3.3 vs. 1.5 h, p = 0.051), but genders did not differ in CT visit hours or average length. By diagnosis, colon/esophageal subjects spent more hours in CT visits (M = 21.90 h, SD = 8.60 h, p < 0.01), and lung subjects trended toward spending more hours in SC visits (M = 4.80 h, SD = 8.23 h, p < 0.06). Advanced-stage cancer patients differed in visit types, hours, and treatment length undergoing CT and SC visits. Age, gender, and diagnosis explained the differences, and this study adds new understanding to the phenomenon of treatment complexity.

  11. Are the studies on cancer risk from CT scans biased by indication? Elements of answer from a large-scale cohort study in France

    PubMed Central

    Journy, N; Rehel, J-L; Ducou Le Pointe, H; Lee, C; Brisse, H; Chateil, J-F; Caer-Lorho, S; Laurier, D; Bernier, M-O

    2015-01-01

    Background: Recent epidemiological results suggested an increase of cancer risk after receiving computed tomography (CT) scans in childhood or adolescence. Their interpretation is questioned due to the lack of information about the reasons for examination. Our objective was to estimate the cancer risk related to childhood CT scans, and examine how cancer-predisposing factors (PFs) affect assessment of the radiation-related risk. Methods: The cohort included 67 274 children who had a first scan before the age of 10 years from 2000 to 2010 in 23 French departments. Cumulative X-rays doses were estimated from radiology protocols. Cancer incidence was retrieved through the national registry of childhood cancers; PF from discharge diagnoses. Results: During a mean follow-up of 4 years, 27 cases of tumours of the central nervous system, 25 of leukaemia and 21 of lymphoma were diagnosed; 32% of them among children with PF. Specific patterns of CT exposures were observed according to PFs. Adjustment for PF reduced the excess risk estimates related to cumulative doses from CT scans. No significant excess risk was observed in relation to CT exposures. Conclusions: This study suggests that the indication for examinations, whether suspected cancer or PF management, should be considered to avoid overestimation of the cancer risks associated with CT scans. PMID:25314057

  12. CT-based investigation of the contraction of ex vivo tissue undergoing microwave thermal ablation

    NASA Astrophysics Data System (ADS)

    Lopresto, Vanni; Strigari, Lidia; Farina, Laura; Minosse, Silvia; Pinto, Rosanna; D'Alessio, Daniela; Cassano, Bartolomeo; Cavagnaro, Marta

    2018-03-01

    Treatment planning in microwave thermal ablation (MTA) requires the capability to predict and estimate the shape and dimension of the thermally coagulated zone obtainable following a clinical protocol. The ultimate result relies on the knowledge of the performance of the ablation device, as well as of the temperature-dependent structural modifications that the tissue undergoes during the treatment, because of the very high temperatures reached (up to 100 °C or higher). In this respect, tissue shrinkage plays an important role, since the dimension of the ablated tissue evaluated at the end of the MTA procedure (e.g. by way of CT imaging) could underestimate the actual treated tissue, leading to inaccurate assessment of the treatment outcome. In this study, CT imaging was used for real-time monitoring of tissue contraction during MTA experiments carried out in ex vivo bovine liver. Fiducial lead markers were positioned into the tissue in a 3D spatial grid around the MTA applicator. The spatial and temporal evolution of tissue contraction was imaged during the experiments, and analysed in terms of displacements of clusters of fiducial markers. The results obtained indicated that contraction is highly heterogeneous in the zone of ablation, depending both on the heating and on interactions with nearby tissue. In particular, tissue shrinkage appeared asymmetric with respect to the direction of insertion of the microwave applicator in the central area of carbonised tissue (about 30% and 19% along the radial and longitudinal directions, respectively), and isotropic in the region of coagulated (but not carbonised) tissue (about 11%). The total ablated volume was reduced by approximately 43% with respect to its pre-ablation value. Finally, temperature measurements displayed a correlation between temperature increment and temporal evolution of tissue contraction in the zone of ablation.

  13. Changes in Brain Structural Networks and Cognitive Functions in Testicular Cancer Patients Receiving Cisplatin-Based Chemotherapy.

    PubMed

    Amidi, Ali; Hosseini, S M Hadi; Leemans, Alexander; Kesler, Shelli R; Agerbæk, Mads; Wu, Lisa M; Zachariae, Robert

    2017-12-01

    Cisplatin-based chemotherapy may have neurotoxic effects within the central nervous system. The aims of this study were 1) to longitudinally investigate the impact of cisplatin-based chemotherapy on whole-brain networks in testicular cancer patients undergoing treatment and 2) to explore whether possible changes are related to decline in cognitive functioning. Sixty-four newly orchiectomized TC patients underwent structural magnetic resonance imaging (T1-weighted and diffusion-weighted imaging) and cognitive testing at baseline prior to further treatment and again at a six-month follow-up. At follow-up, 22 participants had received cisplatin-based chemotherapy (CT) while 42 were in active surveillance (S). Brain structural networks were constructed for each participant, and network properties were investigated using graph theory and longitudinally compared across groups. Cognitive functioning was evaluated using standardized neuropsychological tests. All statistical tests were two-sided. Compared with the S group, the CT group demonstrated altered global and local brain network properties from baseline to follow-up as evidenced by decreases in important brain network properties such as small-worldness (P = .04), network clustering (P = .04), and local efficiency (P = .02). In the CT group, poorer overall cognitive performance was associated with decreased small-worldness (r = -0.46, P = .04) and local efficiency (r = -0.51, P = .02), and verbal fluency was associated with decreased local efficiency (r = -0.55, P = .008). Brain structural networks may be disrupted following treatment with cisplatin-based chemotherapy. Impaired brain networks may underlie poorer performance over time on both specific and nonspecific cognitive functions in patients undergoing chemotherapy. To the best of our knowledge, this is the first study to longitudinally investigate changes in structural brain networks in a cancer population, providing novel insights regarding the neurobiological mechanisms of cancer-related cognitive impairment.

  14. Intrahepatic Left to Right Portoportal Venous Collateral Vascular Formation in Patients Undergoing Right Portal Vein Ligation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lienden, K. P. van, E-mail: k.p.vanlienden@amc.uva.nl; Hoekstra, L. T.; Bennink, R. J.

    2013-12-15

    Purpose: We investigated intrahepatic vascular changes in patients undergoing right portal vein ligation (PVL) or portal vein embolization (PVE) in conjunction with the ensuing hypertrophic response and function of the left liver lobe. Methods: Between December 2008 and October 2011, 7 patients underwent right PVL and 14 patients PVE. Computed tomographic (CT) volumetry to assess future remnant liver (FRL) and functional hepatobiliary scintigraphy were performed in all patients before and 3 weeks after portal vein occlusion. In 18 patients an intraoperative portography was performed to assess perfusion through the occluded portal branches. Results: In all patients after initially successful PVL,more » reperfused portal veins were observed on CT scan 3 weeks after portal occlusion. This was confirmed in all cases during intraoperative portography. Intrahepatic portoportal collaterals were identified in all patients in the PVL group and in one patient in the PVE group. In all other PVE patients, complete occlusion of the embolized portal branches was observed on CT scan and on intraoperative portography. The median increase of FRL volume after PVE was 41.6 % (range 10-305 %), and after PVL was only 8.1 % (range 0-102 %) (p = 0.179). There were no differences in FRL function between both groups. Conclusion: Preoperative PVE and PVL are both methods to induce hypertrophy of the FRL in anticipation of major liver resection. Compared to PVE, PVL seems less efficient in inducing hypertrophy of the nonoccluded left lobe. This could be caused by the formation of intrahepatic portoportal neocollateral vessels, through which the ligated portal branches are reperfused within 3 weeks.« less

  15. Pre-test probability of obstructive coronary stenosis in patients undergoing coronary CT angiography: Comparative performance of the modified diamond-Forrester algorithm versus methods incorporating cardiovascular risk factors.

    PubMed

    Ferreira, António Miguel; Marques, Hugo; Tralhão, António; Santos, Miguel Borges; Santos, Ana Rita; Cardoso, Gonçalo; Dores, Hélder; Carvalho, Maria Salomé; Madeira, Sérgio; Machado, Francisco Pereira; Cardim, Nuno; de Araújo Gonçalves, Pedro

    2016-11-01

    Current guidelines recommend the use of the Modified Diamond-Forrester (MDF) method to assess the pre-test likelihood of obstructive coronary artery disease (CAD). We aimed to compare the performance of the MDF method with two contemporary algorithms derived from multicenter trials that additionally incorporate cardiovascular risk factors: the calculator-based 'CAD Consortium 2' method, and the integer-based CONFIRM score. We assessed 1069 consecutive patients without known CAD undergoing coronary CT angiography (CCTA) for stable chest pain. Obstructive CAD was defined as the presence of coronary stenosis ≥50% on 64-slice dual-source CT. The three methods were assessed for calibration, discrimination, net reclassification, and changes in proposed downstream testing based upon calculated pre-test likelihoods. The observed prevalence of obstructive CAD was 13.8% (n=147). Overestimations of the likelihood of obstructive CAD were 140.1%, 9.8%, and 18.8%, respectively, for the MDF, CAD Consortium 2 and CONFIRM methods. The CAD Consortium 2 showed greater discriminative power than the MDF method, with a C-statistic of 0.73 vs. 0.70 (p<0.001), while the CONFIRM score did not (C-statistic 0.71, p=0.492). Reclassification of pre-test likelihood using the 'CAD Consortium 2' or CONFIRM scores resulted in a net reclassification improvement of 0.19 and 0.18, respectively, which would change the diagnostic strategy in approximately half of the patients. Newer risk factor-encompassing models allow for a more precise estimation of pre-test probabilities of obstructive CAD than the guideline-recommended MDF method. Adoption of these scores may improve disease prediction and change the diagnostic pathway in a significant proportion of patients. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  16. Von Willebrand factor antigen predicts response to double dose of aspirin and clopidogrel by PFA-100 in patients undergoing primary angioplasty for ST elevation myocardial infarction.

    PubMed

    Gianetti, Jacopo; Parri, Maria Serena; Della Pina, Francesca; Marchi, Federica; Koni, Endrin; De Caterina, Alberto; Maffei, Stefano; Berti, Sergio

    2013-01-01

    Von Willebrand factor (VWF) is an emerging risk factor in acute coronary syndromes. Platelet Function Analyzer (PFA-100) with Collagen/Epinephrine (CEPI) is sensitive to functional alterations of VWF and also identifies patients with high on-treatment platelet reactivity (HPR). The objective of this study was to verify the effect of double dose (DD) of aspirin and clopidogrel on HPR detected by PFA-100 and its relation to VWF and to its regulatory metalloprotease ADAMTS-13. Between 2009 and 2011 we enrolled 116 consecutive patients with ST elevation myocardial infarction undergoing primary PCI with HPR at day 5 after PCI. Patients recruited were then randomized between a standard dose (SD, n = 58) or DD of aspirin and clopidogrel (DD, n = 58), maintained for 6 months follow-up. Blood samples for PFA-100, light transmittance aggregometry, and VWF/ADAMTS-13 analysis were collected after 5, 30, and 180 days (Times 0, 1, and 2). At Times 1 and 2 we observed a significantly higher CEPI closure times (CT) in DD as compared to SD (P < 0.001). Delta of CEPI-CT (T1 - T0) was significantly related to VWF (P < 0.001) and inversely related to ADAMTS-13 (0.01). Responders had a significantly higher level of VWF at T0. Finally, in a multivariate model analysis, VWF and ADAMTS-13 in resulted significant predictors of CEPI-CT response (P = 0.02). HRP detected by PFA-100 in acute myocardial infarction is reversible by DD of aspirin and clopidogrel; the response is predicted by basal levels of VWF and ADAMTS-13. PFA-100 may be a useful tool to risk stratification in acute coronary syndromes given its sensitivity to VWF.

  17. Marketing cardiac CT programs.

    PubMed

    Scott, Jason

    2010-01-01

    There are two components of cardiac CT discussed in this article: coronary artery calcium scoring (CACS) and coronary computed tomography angiography (CCTA).The distinctive advantages of each CT examination are outlined. In order to ensure a successful cardiac CT program, it is imperative that imaging facilities market their cardiac CT practices effectively in order to gain a competitive advantage in this valuable market share. If patients receive quality care by competent individuals, they are more likely to recommend the facility's cardiac CT program. Satisfied patients will also be more willing to come back for any further testing.

  18. Synergistic Role of Newer Techniques for Forensic and Postmortem CT Examinations.

    PubMed

    Blum, Alain; Kolopp, Martin; Teixeira, Pedro Gondim; Stroud, Tyler; Noirtin, Philippe; Coudane, Henry; Martrille, Laurent

    2018-04-30

    The aim of this article is to provide an overview of newer techniques and postprocessing tools that improve the potential impact of CT in forensic situations. CT has become a standard tool in medicolegal practice. Postmortem CT is an essential aid to the pathologist during autopsies. Advances in technology and software are constantly leading to advances in its performance.

  19. Three-dimensional CT enterography using oral gastrografin in patients with small bowel obstruction: comparison with axial CT images or fluoroscopic findings.

    PubMed

    Hong, Seong Sook; Kim, Ah Young; Kwon, Seok Beom; Kim, Pyo Nyun; Lee, Moon-Gyu; Ha, Hyun Kwon

    2010-10-01

    To evaluate the feasibility of 3D CT enterography using oral gastrografin in patients with small bowel obstruction (SBO), focusing on improving diagnostic performance as compared with the use of axial CT imagings and fluoroscopic findings. For a 10-month period, 18 patients with known SBO detected clinically and radiologically were enrolled. In all patients, gastrografin was ingested prior to CT enterography. Twelve patients underwent a fluoroscopic examination. Images were randomly assessed for confidence for the level, for the cause of SBO, and for the assessment of the interpretability of each image by two gastrointestinal radiologists. The results were considered statistically significant using the Wilcoxon rank sum test. All patients (100%) well tolerated the administration of oral gastrografin. The use of 3D CT enterography significantly improved diagnostic confidence for the interpretation of the level, cause of SBO, and the assessment of the interpretability of each image as compared with the use of axial CT images (P < 0.05). 3D CT enterography was superior as compared to fluoroscopic examination (P < 0.05). The use of gastrografin for 3D CT enterography is a safe and feasible technique for precise evaluation of known or suspected SBO.

  20. Spectroscopy of Photovoltaic Materials: Charge-Transfer Complexes and Titanium Dioxide

    NASA Astrophysics Data System (ADS)

    Dillon, Robert John

    The successful function of photovoltaic (PV) and photocatalytic (PC) systems centers primarily on the creation and photophysics of charge separated electron-hole pairs. The pathway leading to separate carriers varies by material; organic materials typically require multiple events to charge separate, whereas inorganic semiconductors can directly produce free carriers. In this study, time-resolved spectroscopy is used to provide insight into two such systems: 1) organic charge-transfer (CT) complexes, where electrons and holes are tightly bound to each other, and 2) Au-TiO2 core-shell nanostructures, where free carriers are directly generated. 1) CT complexes are structurally well defined systems consisting of donor molecules, characterized by having low ionization potentials, and acceptor molecules, characterized by having high electron affinities. Charge-transfer is the excitation of an electron from the HOMO of a donor material directly into the LUMO of the acceptor material, leading to an electron and hole separated across the donor:acceptor interface. The energy of the CT transition is often less than that of the bandgaps of donor and acceptor materials individually, sparking much interest if PV systems can utilize the CT band to generate free carriers from low energy photons. In this work we examine the complexes formed between acceptors tetracyanobenzene (TCNB) and tetracyanoquinodimethane (TCNQ) with several aromatic donors. We find excitation of the charge-transfer band of these systems leads to strongly bound electron-hole pairs that exclusively undergo recombination to the ground state. In the case of the TCNB complexes, our initial studies were flummoxed by the samples' generally low threshold for photo and mechanical damage. As our results conflicted with previous literature, a significant portion of this study was spent quantifying the photodegradation process. 2) Unlike the previous system, free carriers are directly photogenerated in TiO2, and the prime consideration is avoiding loss due to recombination of the electron and hole. In this study, four samples of core-shell Au-TiO 2 nanostructures are analyzed for their photocatalytic activity and spectroscopic properties. The samples were made with increasingly crystalline TiO2 shells. The more crystalline samples had higher photocatalytic activities, attributed to longer carrier lifetimes. The observed photophysics of these samples vary with excitation wavelength and detection method used. We find the time-resolved photoluminescence correlates with the samples' photocatalytic activities only when high energy, excitation wavelength less than or equal to 300 nm is used, while transient absorption experiments show no correlation regardless of excitation source. The results imply that photoexcitation with high energy photons can generate both reactive surface sites and photoluminescent surface sites in parallel. Both types of sites then undergo similar electron-hole recombination processes that depend on the crystallinity of the TiO2 shell. Surface sites created by low energy photons, as well as bulk TiO2 carrier dynamics that are probed by transient absorption, do not appear to be sensitive to the same dynamics that determine chemical reactivity.

  1. Accuracy of low dose CT in the diagnosis of appendicitis in childhood and comparison with USG and standard dose CT.

    PubMed

    Yi, Dae Yong; Lee, Kyung Hoon; Park, Sung Bin; Kim, Jee Taek; Lee, Na Mi; Kim, Hyery; Yun, Sin Weon; Chae, Soo Ahn; Lim, In Seok

    Computed tomography should be performed after careful consideration due to radiation hazard, which is why interest in low dose CT has increased recently in acute appendicitis. Previous studies have been performed in adult and adolescents populations, but no studies have reported on the efficacy of using low-dose CT in children younger than 10 years. Patients (n=475) younger than 10 years who were examined for acute appendicitis were recruited. Subjects were divided into three groups according to the examinations performed: low-dose CT, ultrasonography, and standard-dose CT. Subjects were categorized according to age and body mass index (BMI). Low-dose CT was a contributive tool in diagnosing appendicitis, and it was an adequate method, when compared with ultrasonography and standard-dose CT in terms of sensitivity (95.5% vs. 95.0% and 94.5%, p=0.794), specificity (94.9% vs. 80.0% and 98.8%, p=0.024), positive-predictive value (96.4% vs. 92.7% and 97.2%, p=0.019), and negative-predictive value (93.7% vs. 85.7% and 91.3%, p=0.890). Low-dose CT accurately diagnosed patients with a perforated appendix. Acute appendicitis was effectively diagnosed using low-dose CT in both early and middle childhood. BMI did not influence the accuracy of detecting acute appendicitis on low-dose CT. Low-dose CT is effective and accurate for diagnosing acute appendicitis in childhood, as well as in adolescents and young adults. Additionally, low-dose CT was relatively accurate, irrespective of age or BMI, for detecting acute appendicitis. Therefore, low-dose CT is recommended for assessing children with suspected acute appendicitis. Copyright © 2017. Published by Elsevier Editora Ltda.

  2. Pulmonary Aspergillus chest wall involvement in chronic granulomatous disease: CT and MRI findings.

    PubMed

    Kawashima, A; Kuhlman, J E; Fishman, E K; Tempany, C M; Magid, D; Lederman, H M; Winkelstein, J A; Zerhouni, E A

    1991-01-01

    Pulmonary Aspergillus infection in patients with chronic granulomatous disease tends to involve the chest wall and consequently carries a high mortality rate. We report the findings of computed tomography (CT) and magnetic resonance imaging (MRI) in three such cases. One patient underwent both CT and MRI, one, CT only, and one, MRI only. In all three, both CT and MRI demonstrated pulmonary consolidations with direct extension to the adjacent chest wall. In both patients who were examined by CT, scans revealed permeative osteolytic changes of adjacent rib or spine compatible with osteomyelitis. In both patients who were examined by MRI, adjacent chest wall involvement was depicted on T1-weighted images and showed increased signal intensity on T2-weighted images. In one of these patients, the chest wall lesion was well defined on T2-weighted images, an appearance compatible with abscess. Epidural extension was demonstrated on MRI in the other patient, who later developed paraparesis. We suggest that CT and MRI have a complementary role in evaluating chest wall invasion by pulmonary Aspergillus infection in chronic granulomatous disease.

  3. Preoperative and Postoperative CT Scan Assessment of Pterygomaxillary Junction in Patients Undergoing Le Fort I Osteotomy: Comparison of Pterygomaxillary Dysjunction Technique and Trimble Technique-A Pilot Study.

    PubMed

    Dadwal, Himani; Shanmugasundaram, S; Krishnakumar Raja, V B

    2015-09-01

    To determine the rate of complications and occurrence of pterygoid plate fractures comparing two techniques of Le Fort I osteotomy i.e., Classic Pterygomaxillary Dysjunction technique and Trimble technique and to know whether the dimensions of pterygomaxillary junction [determined preoperatively by computed tomography (CT) scan] have any influence on pterygomaxillary separation achieved during surgery. The study group consisted of eight South Indian patients with maxillary excess. A total of 16 sides were examined by CT. Preoperative CT was analyzed for all the patients. The thickness and width of the pterygomaxillary junction and the distance of the greater palatine canal from the pterygomaxillary junction was noted. Pterygomaxillary dysjunction was achieved by two techniques, the classic pterygomaxillary dysjunction technique (Group I) and Trimble technique (Group II). Patients were selected randomly and equally for both the techniques. Dysjunction was analyzed by postoperative CT. The average thickness of the pterygomaxillary junction on 16 sides was 4.5 ± 1.2 mm. Untoward pterygoid plate fractures occurred in Group I in 3 sides out of 8. In Trimble technique (Group II), no pterygoid plate fractures were noted. The average width of the pterygomaxillary junction was 7.8 ± 1.5 mm, distance of the greater palatine canal from pterygomaxillary junction was 7.4 ± 1.6 mm and the length of fusion of pterygomaxillary junction was 8.0 ± 1.9 mm. The Le Fort I osteotomy has become a standard procedure for correcting various dentofacial deformities. In an attempt to make Le Fort I osteotomy safer and avoid the problems associated with sectioning with an osteotome between the maxillary tuberosity and the pterygoid plates, Trimble suggested sectioning across the posterior aspect of the maxillary tuberosity itself. In our study, comparison between the classic pterygomaxillary dysjunction technique and the Trimble technique was made by using postoperative CT scan. It was found that unfavorable pterygoid plate fractures occurred only in dysjunction group and not in Trimble technique group. Preoperative CT scan assessment was done for all the patients to determine the dimension of the pterygomaxillary region. Preoperative CT scan proved to be helpful in not only determining the dimensions of the pterygomaxillary region but we also found out that thickness of the pterygomaxillary junction was an important parameter which may influence the separation at the pterygomaxillary region. No untoward fractures of the pterygoid plates were seen in Trimble technique (Group II) which makes it a safer technique than classic dysjunction technique. It was noted that pterygoid plate fractures occurred in patients in whom the thickness of the pterygomaxillary junction was <3.6 mm (preoperatively). Therefore, preoperative evaluation is important, on the basis of which we can decide upon the technique to be selected for safer and acceptable separation of pterygomaxillary region.

  4. [Bursitis iliopectinea].

    PubMed

    Koudela, K; Koudelová, J; Koudela, K; Kunesová, M

    2008-10-01

    PURPOSE OF THE STUDY To present clinical and radiographic findings of iliopectineal bursitis and draw attention to some related etiopathogenetic factors. MATERIAL AND METHODS Six patients followed up between 2005 and 2007 were evaluated. They included four women and two men (average age, 58 years; range, 35 to 80 years) who presented with a tender mass in the hip region (four right and two left sides). Each patient underwent an examination involving a clinical check-up, imaging methods (CT, MR, angio-CT) and standard laboratory tests. RESULTS Iliopectineal bursitis clinically manifested as a tender mass in the groin and hip region in five patients; in one it was pulsating. The sixth case was asymptomatic. In three patients iliopectineal bursitis was found in association with steroid therapy and subsequent avascular necrosis of the femoral head and chronic synovitis. It followed tularemia with hip joint involvement in one patient, salmonella arthritis in one, and kidney transplant rejection in one. Also, iliopectineal bursitis was diagnosed in a patient with rheumatoid arthritis treated with steroids, but without femoral head avascular necrosis, and was incidentally found in another patient examined for digestive problems. Of the six cases of swollen bursa detected by the imaging methods used, five were found to communicate with the hip joint cavity, with four being so large that the bursa extended into the retroperitoneum. Two patients underwent excision or resection of the bursa; in addition, one of them had revitalizing graft surgery for femoral head necrosis. The patient with salmonella arthritis had to undergo a Girdlestone procedure. One patient was treated by draining of the bursa and, after inflammation resolved, total hip replacement surgery was carried out during which the iliopectineal bursa was removed. The patient with rheumatoid arthritis was treated by bursa draining and refused further surgical therapy (total hip replacement). DISCUSSION In our group of six patients, bursitis was symptomatic in five and was associated with chronic hip synovitis accompanying femoral head necrosis following steroid therapy or inflamation, either non-specific or arthitic. Bursitis was asymptomatic in one patient and was diagnosed only incidentally on CT examination done for another reason. The communication between the bursa and the hip joint cavity, found on CT scans and magnetic resonance images, was a radiographic factor important for differential diagnosis. The underlying disease of the hip joint plays a key role in the etiopathogenesis of iliopectineal bursitis. Therefore, surgical treatment should be comprehensible and, in addition to bursa resection or excision, should also include treatment of the affected joint (alloplasty, femoral head resection or revitalization). CONCLUSION Iliopectineal bursitis is associated with chronic hip synovitis present in degenerative, infectious or rheumatic joint diseases. When a lump is diagnosed in the inguinal or hip region, iliopectineal bursitis should always be considered in addition to conditions such as abscess, cyst, hernia, pseudoaneurysm, lymphocele, etc. The finding of communication beteen the bursa and hip joint cavity, made on CT scans or magnetic resonance images, is a radiographic factor important in terms of differential diagnosis. The surgical treatment of iliopectineal bursitis includes excision or resection of the bursa and therapy for the hip joint (alloplasty, femoral head resection or revitalization).

  5. Mixed Germ Cell Tumour in an Infertile Male Having Unilateral Cryptorchidism: A Rare Case Report.

    PubMed

    Singla, Anand; Kaur, Navneet; Sandhu, Gunjeet; Nagori, Rupesh

    2016-02-01

    Mixed germ cell tumours with multiple components occur more frequently than the pure varieties of germ cell tumours. Embryonal carcinoma and teratoma together form the most common components of the mixed germ cell tumour but the yolk sac tumour is usually seen as a minor component in patients presenting with mixed germ cell tumour. We report a rare case of 27-year-old Hepatitis C positive male presenting with pain in left lower abdomen with associated history of same sided undescended testis and infertility. Right sided testis lying in scrotal sac appeared normal on ultrasonography but patient was azoospermic. He had raised levels of serum markers, alpha feto protein and beta HCG. Examination showed a large mass in left lower abdomen involving the sigmoid colon with the absence of left testis in left scrotum which was confirmed on CT scan. Excision of the mass was done and histopathology examination revealed it as a malignant mixed germ cell tumour composed predominantly of a yolk sac tumour, with minor component as seminoma and embryonal carcinoma in an undescended testis. Following this, the level of serum markers came down. The patient is now undergoing adjuvant chemotherapy and is doing well.

  6. Endoscopic ultrasonography predicts early esophageal variceal bleeding in liver cirrhosis: A case report.

    PubMed

    Men, Changjun; Zhang, Guoliang

    2017-04-01

    Bleeding esophageal and gastric varices constitute a serious complication in liver cirrhosis. Previous studies have shown that endoscopic ultrasonography (EUS) can be used to predict early esophageal variceal bleeding in liver cirrhosis. We report a case of a 46-year-old man with hepatitis B liver cirrhosis (CTP score, 5; Child-Pugh class, A) who was admitted to our hospital due to a decreased appetite lasting 1 week. He was initially diagnosed with decompensated hepatitis B cirrhosis; an abdominal computed tomography (CT) scan indicated a diagnosis of liver cirrhosis and portal hypertension (PHT). Common endoscopic examination showed no evidence of gastroesophageal varices; EUS revealed distinct varices of the esophageal and gastric veins. Six months after discharge, the patient was rehospitalized because of upper gastrointestinal bleeding. Endoscopic ligation was implemented as well as esophageal varices loop ligature (EVL). Six months later, EUS showed obvious collateral and perforator veins. We should strongly recommend that patients with liver cirrhosis undergo EUS in addition to a routine endoscopic examination. EUS can play an important role in evaluating the risk for bleeding in PHT and can be used to assess the efficacy of EVL.

  7. A Major Upgrade of the H.E.S.S. Cherenkov Cameras

    NASA Astrophysics Data System (ADS)

    Lypova, Iryna; Giavitto, Gianluca; Ashton, Terry; Balzer, Arnim; Berge, David; Brun, Francois; Chaminade, Thomas; Delagnes, Eric; Fontaine, Gerard; Füßling, Matthias; Giebels, Berrie; Glicenstein, Jean-Francois; Gräber, Tobias; Hinton, Jim; Jahnke, Albert; Klepser, Stefan; Kossatz, Marko; Kretzschmann, Axel; Lefranc, Valentin; Leich, Holger; Lüdecke, Hartmut; Manigot, Pascal; Marandon, Vincent; Moulin, Emmanuel; de Naurois, Mathieu; Nayman, Patrick; Ohm, Stefan; Penno, Marek; Ross, Duncan; Salek, David; Schade, Markus; Schwab, Thomas; Simoni, Rachel; Stegmann, Christian; Steppa, Constantin; Thornhill, Julian; Toussnel, Francois

    2017-03-01

    The High Energy Stereoscopic System (H.E.S.S.) is an array of imaging atmospheric Cherenkov telescopes (IACTs) located in Namibia. It was built to detect Very High Energy (VHE, >100 GeV) cosmic gamma rays, and consists of four 12 m diameter Cherenkov telescopes (CT1-4), built in 2003, and a larger 28 m telescope (CT5), built in 2012. The larger mirror surface of CT5 permits to lower the energy threshold of the array down to 30 GeV. The cameras of CT1-4 are currently undergoing an extensive upgrade, with the goals of reducing their failure rate, reducing their readout dead time and improving the overall performance of the array. The entire camera electronics has been renewed from ground-up, as well as the power, ventilation and pneumatics systems, and the control and data acquisition software. Technical solutions forseen for the next-generation Cherenkov Telescope Array (CTA) observatory have been introduced, most notably the readout is based on the NECTAr analog memory chip. The camera control subsystems and the control software framework also pursue an innovative design, increasing the camera performance, robustness and flexibility. The CT1 camera has been upgraded in July 2015 and is currently taking data; CT2-4 will upgraded in Fall 2016. Together they will assure continuous operation of H.E.S.S at its full sensitivity until and possibly beyond the advent of CTA. This contribution describes the design, the testing and the in-lab and on-site performance of all components of the newly upgraded H.E.S.S. camera.

  8. Use of computed tomography to identify atrial fibrillation associated differences in left atrial wall thickness and density.

    PubMed

    Dewland, Thomas A; Wintermark, Max; Vaysman, Anna; Smith, Lisa M; Tong, Elizabeth; Vittinghoff, Eric; Marcus, Gregory M

    2013-01-01

    Left atrial (LA) tissue characteristics may play an important role in atrial fibrillation (AF) induction and perpetuation. Although frequently used in clinical practice, computed tomography (CT) has not been employed to describe differences in LA wall properties between AF patients and controls. We sought to noninvasively characterize AF-associated differences in LA tissue using CT. CT images of the LA were obtained in 98 consecutive patients undergoing AF ablation and in 89 controls. A custom software algorithm was used to measure wall thickness and density in four prespecified regions of the LA. On average, LA walls were thinner (-15.5%, 95% confidence interval [CI] -23.2 to -7.8%, P < 0.001) and demonstrated significantly lower density (-19.7 Hounsfield Units [HU], 95% CI -27.0 to -12.5 HU, P < 0.001) in AF patients compared to controls. In linear mixed models adjusting for demographics, clinical variables, and other CT measurements, the average LA, interatrial septum, LA appendage, and anterior walls remained significantly thinner in AF patients. After adjusting for the same potential confounders, history of AF was associated with reduced density in the LA anterior wall and increased density below the right inferior pulmonary vein and in the LA appendage. Application of an automated measurement algorithm to CT imaging of the atrium identified significant thinning of the LA wall and regional alterations in tissue density in patients with a history of AF. These findings suggest differences in LA tissue composition can be noninvasively identified and quantified using CT. ©2012, The Authors. Journal compilation ©2012 Wiley Periodicals, Inc.

  9. Effect of localizer radiograph on radiation dose associated with automatic exposure control: human cadaver and patient study.

    PubMed

    Singh, Sarabjeet; Petrovic, Dean; Jamnik, Ethen; Aran, Shima; Pourjabbar, Sarvenaz; Kave, Maggie L; Bradley, Stephen E; Choy, Garry; Kalra, Mannudeep K

    2014-01-01

    To evaluate the effect of localizing radiograph on computed tomography (CT) radiation dose associated with automatic exposure control with a human cadaver and patient study. Institutional review board approved the study with a waiver of informed consent. Two chest CT image series with fixed tube current and combined longitudinal-angular automatic exposure control (AEC) were acquired in a human cadaver (64-year-old man) after each of the 8 combinations of localizer radiographs (anteroposterior [AP], AP lateral, AP-posteroanterior [PA], lateral AP, lateral PA, PA, PA-AP, and PA lateral). Applied effective milliampere second, volume CT dose index (CTDIvol) and image noise were recorded for all 24-image series. Volume CT dose indexes were also recorded in 20 patients undergoing chest and abdominal CT after PA and PA-lateral radiographs with the use of AEC. Data were analyzed using analysis of variance and linear correlation tests. With AEC, the CTDIvol fluctuates with the number and projection of localizer radiographs (P < 0.0001). Lowest CTDIvol values are seen when 2 orthogonal localizer radiographs are acquired, whereas highest values are seen when single PA or AP-PA projection localizer radiographs are acquired for planning (P < 0.0001). In 20 patients, CT scanning with AEC after acquisition of 2 orthogonal projection localizer radiographs was associated with significant reduction in radiation dose compared to PA projection radiographs alone (P < 0.0001). When scanning with AEC, acquisition of 2 orthogonal localizer radiographs is associated with lower CTDIvol compared to a single localizer radiograph.

  10. Variance in predicted cup size by 2-dimensional vs 3-dimensional computerized tomography-based templating in primary total hip arthroplasty.

    PubMed

    Osmani, Feroz A; Thakkar, Savyasachi; Ramme, Austin; Elbuluk, Ameer; Wojack, Paul; Vigdorchik, Jonathan M

    2017-12-01

    Preoperative total hip arthroplasty templating can be performed with radiographs using acetate prints, digital viewing software, or with computed tomography (CT) images. Our hypothesis is that 3D templating is more precise and accurate with cup size prediction as compared to 2D templating with acetate prints and digital templating software. Data collected from 45 patients undergoing robotic-assisted total hip arthroplasty compared cup sizes templated on acetate prints and OrthoView software to MAKOplasty software that uses CT scan. Kappa analysis determined strength of agreement between each templating modality and the final size used. t tests compared mean cup-size variance from the final size for each templating technique. Interclass correlation coefficient (ICC) determined reliability of digital and acetate planning by comparing predictions of the operating surgeon and a blinded adult reconstructive fellow. The Kappa values for CT-guided, digital, and acetate templating with the final size was 0.974, 0.233, and 0.262, respectively. Both digital and acetate templating significantly overpredicted cup size, compared to CT-guided methods ( P < .001). There was no significant difference between digital and acetate templating ( P  = .117). Interclass correlation coefficient value for digital and acetate templating was 0.928 and 0.931, respectively. CT-guided planning more accurately predicts hip implant cup size when compared to the significant overpredictions of digital and acetate templating. CT-guided templating may also lead to better outcomes due to bone stock preservation from a smaller and more accurate cup size predicted than that of digital and acetate predictions.

  11. SPECT/CT with radiolabeled somatostatin analogues in the evaluation of systemic granulomatous infections

    PubMed Central

    Monteiro, Paulo Henrique Silva; de Souza, Thiago Ferreira; Moretti, Maria Luiza; Resende, Mariangela Ribeiro; Mengatti, Jair; de Lima, Mariana da Cunha Lopes; Santos, Allan Oliveira; Ramos, Celso Darío

    2017-01-01

    Objective To evaluate SPECT/CT with radiolabeled somatostatin analogues (RSAs) in systemic granulomatous infections in comparison with gallium-67 (67Ga) citrate scintigraphy. Materials and Methods We studied 28 patients with active systemic granulomatous infections, including tuberculosis, paracoccidioidomycosis, pneumocystosis, cryptococcosis, aspergillosis, leishmaniasis, infectious vasculitis, and an unspecified opportunistic infection. Of the 28 patients, 23 had started specific treatment before the study outset. All patients underwent whole-body SPECT/CT imaging: 7 after injection of 99mTc-EDDA-HYNIC-TOC, and 21 after injection of 111In-DTPA-octreotide. All patients also underwent 67Ga citrate imaging, except for one patient who died before the 67Ga was available. Results In 20 of the 27 patients who underwent imaging with both tracers, 27 sites of active disease were detected by 67Ga citrate imaging and by SPECT/CT with an RSA. Both tracers had negative results in the other 7 patients. RSA uptake was visually lower than 67Ga uptake in 11 of the 20 patients with positive images and similar to 67Ga uptake in the other 9 patients. The only patient who did not undergo 67Ga scintigraphy underwent 99mTc-EDDA-HYNIC-TOC SPECT/CT-guided biopsy of a lung cavity with focal RSA uptake, which turned to be positive for aspergillosis. Conclusion SPECT/CT with 99mTc-EDDA-HYNIC-TOC or 111In-DTPA-octreotide seems to be a good alternative to 67Ga citrate imaging for the evaluation of patients with systemic granulomatous disease. PMID:29307928

  12. Interobserver reliability of computed tomographic contouring of canine tonsils in radiation therapy treatment planning.

    PubMed

    Murakami, Keiko; Rancilio, Nicholas J; Plantenga, Jeannie Poulson; Moore, George E; Heng, Hock Gan; Lim, Chee Kin

    2018-05-01

    In radiation therapy (RT) treatment planning for canine head and neck cancer, the tonsils may be included as part of the treated volume. Delineation of tonsils on computed tomography (CT) scans is difficult. Error or uncertainty in the volume and location of contoured structures may result in treatment failure. The purpose of this prospective, observer agreement study was to assess the interobserver agreement of tonsillar contouring by two groups of trained observers. Thirty dogs undergoing pre- and post-contrast CT studies of the head were included. After the pre- and postcontrast CT scans, the tonsils were identified via direct visualization, barium paste was applied bilaterally to the visible tonsils, and a third CT scan was acquired. Data from each of the three CT scans were registered in an RT treatment planning system. Two groups of observers (one veterinary radiologist and one veterinary radiation oncologist in each group) contoured bilateral tonsils by consensus, obtaining three sets of contours. Tonsil volume and location data were obtained from both groups. The contour volumes and locations were compared between groups using mixed (fixed and random effect) linear models. There was no significant difference between each group's contours in terms of three-dimensional coordinates. However there was a significant difference between each group's contours in terms of the tonsillar volume (P < 0.0001). Pre- and postcontrast CT can be used to identify the location of canine tonsils with reasonable agreement between trained observers. Discrepancy in tonsillar volume between groups of trained observers may affect RT treatment outcome. © 2017 American College of Veterinary Radiology.

  13. Lumbar spine spondylolysis in the adult population: using computed tomography to evaluate the possibility of adult onset lumbar spondylosis as a cause of back pain.

    PubMed

    Brooks, Benjamin K; Southam, Samuel L; Mlady, Gary W; Logan, Jeremy; Rosett, Matthew

    2010-07-01

    To determine if new onset of low back pain in adults could be secondary to lumbar spondylolysis by establishing the age-related prevalence in the general population by examining patients undergoing computed tomography (CT) for reasons unrelated to back pain. The records of 2,555 patients who had undergone abdominal and pelvic CT in 2008 were reviewed electronically. In order to determine a true representation of the general population, we reviewed all indications for CT, excluding patients with a primary complaint of low back pain as the primary indication for imaging. Equal numbers of patients were separated into age groups by decade to ensure an even distribution of ages for statistical analysis. Patients older than 70 years were grouped together to provide case numbers comparable to those of the other decades. Logistic regression analysis was performed to evaluate the significance of the results. Three board-certified radiologists, including two musculoskeletal fellows and a radiology resident, retrospectively evaluated CT scans for lumbar spondylolysis, including unilateral and bilateral defects. Of the 2,555 cases evaluated, there were 203 positive cases of defects of the lumbar pars interarticularis. This corresponded to an overall prevalence of 8.0%. Prevalence per decade was fairly evenly distributed and ranged from 7.0%( ages 30-39 years) to 9.2% (ages 70 years and above). Prevalence of ages 20-49 years was 7.9%, and that of ages 50 years and older was 8.0%. Male to female ratio was 1.5:1. Logistic regression showed no significant increase in spondylolysis based on age. No significant increase in the prevalence of lumbar spondylolysis was demonstrated in patients older than 20 years. This suggests that the development of symptomatic lumbar pars defects do not occur in this population and should not be considered as a rare but potentially treatable cause of new onset low back pain in adults. This study demonstrated an overall prevalence of pars defects of 8.0% in our population. As demonstrated in previous studies, the male to female ratio of 1.5:1 was a statistically significant difference.

  14. Do physical examination and CT-scan measures of femoral neck anteversion and tibial torsion relate to each other?

    PubMed

    Sangeux, Morgan; Mahy, Jessica; Graham, H Kerr

    2014-01-01

    Informed clinical decision making for femoral and/or tibial de-rotation osteotomies requires accurate measurement of patient function through gait analysis and anatomy through physical examination of bony torsions. Validity of gait analysis has been extensively studied; however, controversy remains regarding the accuracy of physical examination measurements of femoral and tibial torsion. Comparison between CT-scans and physical examination measurements of femoral neck anteversion (FNA) and external tibial torsion (ETT) were retrospectively obtained for 98 (FNA) and 64 (ETT) patients who attended a tertiary hospital for instrumented gait analysis between 2007 and 2010. The physical examination methods studied for femoral neck anteversion were the trochanteric prominence angle test (TPAT) and the maximum hip rotation arc midpoint (Arc midpoint) and for external tibial torsion the transmalleolar axis (TMA). Results showed that all physical examination measurements statistically differed to the CT-scans (bias(standard deviation): -2(14) for TPAT, -10(12) for Arc midpoint and -16(9) for TMA). Bland and Altman plots showed that method disagreements increased with increasing bony torsions in all cases but notably for TPAT. Regression analysis showed that only TMA and CT-scan measurement of external tibial torsion demonstrated good (R(2)=57%) correlation. Correlations for both TPAT (R(2)=14%) and Arc midpoint (R(2)=39%) with CT-scan measurements of FNA were limited. We conclude that physical examination should be considered as screening techniques rather than definitive measurement methods for FNA and ETT. Further research is required to develop more accurate measurement methods to accompany instrumented gait analysis. Copyright © 2013. Published by Elsevier B.V.

  15. Comparing risk estimates following diagnostic CT radiation exposures employing different methodological approaches.

    PubMed

    Kashcheev, Valery V; Pryakhin, Evgeny A; Menyaylo, Alexander N; Chekin, Sergey Yu; Ivanov, Viktor K

    2014-06-01

    The current study has two aims: the first is to quantify the difference between radiation risks estimated with the use of organ or effective doses, particularly when planning pediatric and adult computed tomography (CT) examinations. The second aim is to determine the method of calculating organ doses and cancer risk using dose-length product (DLP) for typical routine CT examinations. In both cases, the radiation-induced cancer risks from medical CT examinations were evaluated as a function of gender and age. Lifetime attributable risk values from CT scanning were estimated with the use of ICRP (Publication 103) risk models and Russian national medical statistics data. For populations under the age of 50 y, the risk estimates based on organ doses usually are 30% higher than estimates based on effective doses. In older populations, the difference can be up to a factor of 2.5. The typical distributions of organ doses were defined for Chest Routine, Abdominal Routine, and Head Routine examinations. The distributions of organ doses were dependent on the anatomical region of scanning. The most exposed organs/tissues were thyroid, breast, esophagus, and lungs in cases of Chest Routine examination; liver, stomach, colon, ovaries, and bladder in cases of Abdominal Routine examination; and brain for Head Routine examinations. The conversion factors for calculation of typical organ doses or tissues at risk using DLP were determined. Lifetime attributable risk of cancer estimated with organ doses calculated from DLP was compared with the risk estimated on the basis of organ doses measured with the use of silicon photodiode dosimeters. The estimated difference in LAR is less than 29%.

  16. Ward nurses' knowledge of computed tomography scanning.

    PubMed

    Majeed, M A; Nayeemuddin, M; Christie, M

    Patients benefit from and are reassured by advance information on procedures that they are to undergo. Ward nurses should have adequate knowledge of radiological investigations to ensure proper patient preparation and good interdepartmental communication to avoid delays and cancellations. This study was conducted to assess the ward nurses' knowledge of the process of computed tomography (CT) scanning. One hundred and twenty qualified nurses were asked to complete a questionnaire regarding CT scanning. The findings revealed a suboptimal level of awareness about the process. This is probably due to lack of formal teaching for nurses on the wards in regards the different radiological procedures and patient preparation. There is a strong case for better educational talks on rapidly changing radiological techniques for ward staff to ensure high-quality patient care.

  17. ⁶⁸Ga-DOTA-TOC-PET/CT detects heart metastases from ileal neuroendocrine tumors.

    PubMed

    Calissendorff, Jan; Sundin, Anders; Falhammar, Henrik

    2014-09-01

    Metastases from ileal neuroendocrine tumors (NETs) to the myocardium are rare and generally seen in patients with widespread metastatic NET disease. The objectives of this investigation were to describe the frequency of intracardiac metastases in ileal NET patients examined by (68)Ga-DOTA-TOC-PET/CT and to describe the cases in detail. All (68)Ga-DOTA-TOC-PET/CT examinations performed at the Karolinska University Hospital since 2010 until April 2012 were reviewed. In all, 128 out of 337 examinations were in patients with ileal NETs. Four patients had seven myocardiac metastases, yielding a frequency of 4.3 % in patients with ileal NETs. One patient had cardiac surgery while three were treated with somatostatin analogs. The cardiac metastases did not affect the patients' activity of daily life. (68)Ga-DOTA-TOC-PET/CT is an established imaging modality in identifying cardiac metastases in ileal NETs. Prospective studies are needed to confirm the true clinical value of (68)Ga-DOTA-TOC-PET/CT in detecting cardiac metastases in both ileal and non-ileal NETs.

  18. Computed tomography or rhinoscopy as the first-line procedure for suspected nasal tumor: a pilot study.

    PubMed

    Finck, Marlène; Ponce, Frédérique; Guilbaud, Laurent; Chervier, Cindy; Floch, Franck; Cadoré, Jean-Luc; Chuzel, Thomas; Hugonnard, Marine

    2015-02-01

    There are no evidence-based guidelines as to whether computed tomography (CT) or endoscopy should be selected as the first-line procedure when a nasal tumor is suspected in a dog or a cat and only one examination can be performed. Computed tomography and rhinoscopic features of 17 dogs and 5 cats with a histopathologically or cytologically confirmed nasal tumor were retrospectively reviewed. The level of suspicion for nasal neoplasia after CT and/or rhinoscopy was compared to the definitive diagnosis. Twelve animals underwent CT, 14 underwent rhinoscopy, and 4 both examinations. Of the 12 CT examinations performed, 11 (92%) resulted in the conclusion that a nasal tumor was the most likely diagnosis compared with 9/14 (64%) for rhinoscopies. Computed tomography appeared to be more reliable than rhinoscopy for detecting nasal tumors and should therefore be considered as the first-line procedure.

  19. Computed tomography or rhinoscopy as the first-line procedure for suspected nasal tumor: A pilot study

    PubMed Central

    Finck, Marlène; Ponce, Frédérique; Guilbaud, Laurent; Chervier, Cindy; Floch, Franck; Cadoré, Jean-Luc; Chuzel, Thomas; Hugonnard, Marine

    2015-01-01

    There are no evidence-based guidelines as to whether computed tomography (CT) or endoscopy should be selected as the first-line procedure when a nasal tumor is suspected in a dog or a cat and only one examination can be performed. Computed tomography and rhinoscopic features of 17 dogs and 5 cats with a histopathologically or cytologically confirmed nasal tumor were retrospectively reviewed. The level of suspicion for nasal neoplasia after CT and/or rhinoscopy was compared to the definitive diagnosis. Twelve animals underwent CT, 14 underwent rhinoscopy, and 4 both examinations. Of the 12 CT examinations performed, 11 (92%) resulted in the conclusion that a nasal tumor was the most likely diagnosis compared with 9/14 (64%) for rhinoscopies. Computed tomography appeared to be more reliable than rhinoscopy for detecting nasal tumors and should therefore be considered as the first-line procedure. PMID:25694669

  20. Scenes from the past: initial investigation of early jurassic vertebrate fossils with multidetector CT.

    PubMed

    Bolliger, Stephan A; Ross, Steffen; Thali, Michael J; Hostettler, Bernhard; Menkveld-Gfeller, Ursula

    2012-01-01

    The study of fossils permits the reconstruction of past life on our planet and enhances our understanding of evolutionary processes. However, many fossils are difficult to recognize, being encased in a lithified matrix whose tedious removal is required before examination is possible. The authors describe the use of multidetector computed tomography (CT) in locating, identifying, and examining fossil remains of crocodilians (Mesosuchia) embedded in hard shale, all without removing the matrix. In addition, they describe how three-dimensional (3D) reformatted CT images provided details that were helpful for extraction and preparation. Multidetector CT can help experienced paleontologists localize and characterize fossils in the matrix of a promising rock specimen in a nondestructive manner. Moreover, with its capacity to generate highly accurate 3D images, multidetector CT can help determine whether the fossils warrant extraction and can assist in planning the extraction process. Thus, multidetector CT may well become an invaluable tool in the field of paleoradiology.

Top