Dynamics of a magnetic active Brownian particle under a uniform magnetic field.
Vidal-Urquiza, Glenn C; Córdova-Figueroa, Ubaldo M
2017-11-01
The dynamics of a magnetic active Brownian particle undergoing three-dimensional Brownian motion, both translation and rotation, under the influence of a uniform magnetic field is investigated. The particle self-propels at a constant speed along its magnetic dipole moment, which reorients due to the interplay between Brownian and magnetic torques, quantified by the Langevin parameter α. In this work, the time-dependent active diffusivity and the crossover time (τ^{cross})-from ballistic to diffusive regimes-are calculated through the time-dependent correlation function of the fluctuations of the propulsion direction. The results reveal that, for any value of α, the particle undergoes a directional (or ballistic) propulsive motion at very short times (t≪τ^{cross}). In this regime, the correlation function decreases linearly with time, and the active diffusivity increases with it. It the opposite time limit (t≫τ^{cross}), the particle moves in a purely diffusive regime with a correlation function that decays asymptotically to zero and an active diffusivity that reaches a constant value equal to the long-time active diffusivity of the particle. As expected in the absence of a magnetic field (α=0), the crossover time is equal to the characteristic time scale for rotational diffusion, τ_{rot}. In the presence of a magnetic field (α>0), the correlation function, the active diffusivity, and the crossover time decrease with increasing α. The magnetic field regulates the regimes of propulsion of the particle. Here, the field reduces the period of time at which the active particle undergoes a directional motion. Consequently, the active particle rapidly reaches a diffusive regime at τ^{cross}≪τ_{rot}. In the limit of weak fields (α≪1), the crossover time decreases quadratically with α, while in the limit of strong fields (α≫1) it decays asymptotically as α^{-1}. The results are in excellent agreement with those obtained by Brownian dynamics simulations.
Dynamics of a magnetic active Brownian particle under a uniform magnetic field
NASA Astrophysics Data System (ADS)
Vidal-Urquiza, Glenn C.; Córdova-Figueroa, Ubaldo M.
2017-11-01
The dynamics of a magnetic active Brownian particle undergoing three-dimensional Brownian motion, both translation and rotation, under the influence of a uniform magnetic field is investigated. The particle self-propels at a constant speed along its magnetic dipole moment, which reorients due to the interplay between Brownian and magnetic torques, quantified by the Langevin parameter α . In this work, the time-dependent active diffusivity and the crossover time (τcross)—from ballistic to diffusive regimes—are calculated through the time-dependent correlation function of the fluctuations of the propulsion direction. The results reveal that, for any value of α , the particle undergoes a directional (or ballistic) propulsive motion at very short times (t ≪τcross ). In this regime, the correlation function decreases linearly with time, and the active diffusivity increases with it. It the opposite time limit (t ≫τcross ), the particle moves in a purely diffusive regime with a correlation function that decays asymptotically to zero and an active diffusivity that reaches a constant value equal to the long-time active diffusivity of the particle. As expected in the absence of a magnetic field (α =0 ), the crossover time is equal to the characteristic time scale for rotational diffusion, τrot. In the presence of a magnetic field (α >0 ), the correlation function, the active diffusivity, and the crossover time decrease with increasing α . The magnetic field regulates the regimes of propulsion of the particle. Here, the field reduces the period of time at which the active particle undergoes a directional motion. Consequently, the active particle rapidly reaches a diffusive regime at τcross≪τrot . In the limit of weak fields (α ≪1 ), the crossover time decreases quadratically with α , while in the limit of strong fields (α ≫1 ) it decays asymptotically as α-1. The results are in excellent agreement with those obtained by Brownian dynamics simulations.
Ferraro, D; Lin, Y; Teste, B; Talbot, D; Malaquin, L; Descroix, S; Abou-Hassan, A
2015-12-11
We present a microfluidic platform that allows undergoing different chemical operations in a nanoliter droplet starting from the colloidal suspension of magnetic iron oxide (γ-Fe2O3) nanoparticles "NPs" (ferrofluid). These operations include: mixing, flocculation, magnetic decantation, colloidal redispersion, washing, surface functionalization, heating and colloidal assembly. To prove the platform capabilities, we produced fluorescent and magnetic nanoassemblies composed of fluorescent silica and magnetic NPs.
Magnetic assembly of transparent and conducting graphene-based functional composites
NASA Astrophysics Data System (ADS)
Le Ferrand, Hortense; Bolisetty, Sreenath; Demirörs, Ahmet F.; Libanori, Rafael; Studart, André R.; Mezzenga, Raffaele
2016-06-01
Innovative methods producing transparent and flexible electrodes are highly sought in modern optoelectronic applications to replace metal oxides, but available solutions suffer from drawbacks such as brittleness, unaffordability and inadequate processability. Here we propose a general, simple strategy to produce hierarchical composites of functionalized graphene in polymeric matrices, exhibiting transparency and electron conductivity. These are obtained through protein-assisted functionalization of graphene with magnetic nanoparticles, followed by magnetic-directed assembly of the graphene within polymeric matrices undergoing sol-gel transitions. By applying rotating magnetic fields or magnetic moulds, both graphene orientation and distribution can be controlled within the composite. Importantly, by using magnetic virtual moulds of predefined meshes, graphene assembly is directed into double-percolating networks, reducing the percolation threshold and enabling combined optical transparency and electrical conductivity not accessible in single-network materials. The resulting composites open new possibilities on the quest of transparent electrodes for photovoltaics, organic light-emitting diodes and stretchable optoelectronic devices.
Magnetically actuated tissue engineered scaffold: insights into mechanism of physical stimulation
NASA Astrophysics Data System (ADS)
Sapir-Lekhovitser, Yulia; Rotenberg, Menahem Y.; Jopp, Juergen; Friedman, Gary; Polyak, Boris; Cohen, Smadar
2016-02-01
Providing the right stimulatory conditions resulting in efficient tissue promoting microenvironment in vitro and in vivo is one of the ultimate goals in tissue development for regenerative medicine. It has been shown that in addition to molecular signals (e.g. growth factors) physical cues are also required for generation of functional cell constructs. These cues are particularly relevant to engineering of biological tissues, within which mechanical stress activates mechano-sensitive receptors, initiating biochemical pathways which lead to the production of functionally mature tissue. Uniform magnetic fields coupled with magnetizable nanoparticles embedded within three dimensional (3D) scaffold structures remotely create transient physical forces that can be transferrable to cells present in close proximity to the nanoparticles. This study investigated the hypothesis that magnetically responsive alginate scaffold can undergo reversible shape deformation due to alignment of scaffold's walls in a uniform magnetic field. Using custom made Helmholtz coil setup adapted to an Atomic Force Microscope we monitored changes in matrix dimensions in situ as a function of applied magnetic field, concentration of magnetic particles within the scaffold wall structure and rigidity of the matrix. Our results show that magnetically responsive scaffolds exposed to an externally applied time-varying uniform magnetic field undergo a reversible shape deformation. This indicates on possibility of generating bending/stretching forces that may exert a mechanical effect on cells due to alternating pattern of scaffold wall alignment and relaxation. We suggest that the matrix structure deformation is produced by immobilized magnetic nanoparticles within the matrix walls resulting in a collective alignment of scaffold walls upon magnetization. The estimated mechanical force that can be imparted on cells grown on the scaffold wall at experimental conditions is in the order of 1 pN, which correlates well with reported threshold to induce mechanotransduction effects on cellular level. This work is our next step in understanding of how to accurately create proper stimulatory microenvironment for promotion of cellular organization to form mature tissue engineered constructs.
Magnetically actuated tissue engineered scaffold: insights into mechanism of physical stimulation
Sapir-Lekhovitser, Yulia; Rotenberg, Menahem Y.; Jopp, Juergen; Friedman, Gary; Polyak, Boris; Cohen, Smadar
2016-01-01
Providing the right stimulatory conditions resulting in efficient tissue promoting microenvironment in vitro and in vivo is one of the ultimate goals in tissue development for regenerative medicine. It has been shown that in addition to molecular signals (e.g. growth factors) physical cues are also required for generation of functional cell constructs. These cues are particularly relevant to engineering of biological tissues, within which mechanical stress activates mechano-sensitive receptors, initiating biochemical pathways which lead to the production of functionally mature tissue. Uniform magnetic fields coupled with magnetizable nanoparticles embedded within three dimensional (3D) scaffold structures remotely create transient physical forces that can be transferrable to cells present in close proximity to the nanoparticles. This study investigated the hypothesis that magnetically responsive alginate scaffold can undergo reversible shape deformation due to alignment of scaffold’s walls in a uniform magnetic field. Using custom made Helmholtz coil setup adapted to an Atomic Force Microscope we monitored changes in matrix dimensions in situ as a function of applied magnetic field, concentration of magnetic particles within the scaffold wall structure and rigidity of the matrix. Our results show that magnetically responsive scaffolds exposed to an externally applied time-varying uniform magnetic field undergo a reversible shape deformation. This indicates on possibility of generating bending/stretching forces that may exert a mechanical effect on cells due to alternating pattern of scaffold wall alignment and relaxation. We suggest that the matrix structure deformation is produced by immobilized magnetic nanoparticles within the matrix walls resulting in a collective alignment of scaffold walls upon magnetization. The estimated mechanical force that can be imparted on cells grown on the scaffold wall at experimental conditions is in the order of 1 pN, which correlates well with reported threshold to induce mechanotransduction effects on cellular level. This work is our next step in understanding of how to accurately create proper stimulatory microenvironment for promotion of cellular organization to form mature tissue engineered constructs. PMID:26790538
Magnetic assembly of transparent and conducting graphene-based functional composites
Le Ferrand, Hortense; Bolisetty, Sreenath; Demirörs, Ahmet F.; Libanori, Rafael; Studart, André R.; Mezzenga, Raffaele
2016-01-01
Innovative methods producing transparent and flexible electrodes are highly sought in modern optoelectronic applications to replace metal oxides, but available solutions suffer from drawbacks such as brittleness, unaffordability and inadequate processability. Here we propose a general, simple strategy to produce hierarchical composites of functionalized graphene in polymeric matrices, exhibiting transparency and electron conductivity. These are obtained through protein-assisted functionalization of graphene with magnetic nanoparticles, followed by magnetic-directed assembly of the graphene within polymeric matrices undergoing sol–gel transitions. By applying rotating magnetic fields or magnetic moulds, both graphene orientation and distribution can be controlled within the composite. Importantly, by using magnetic virtual moulds of predefined meshes, graphene assembly is directed into double-percolating networks, reducing the percolation threshold and enabling combined optical transparency and electrical conductivity not accessible in single-network materials. The resulting composites open new possibilities on the quest of transparent electrodes for photovoltaics, organic light-emitting diodes and stretchable optoelectronic devices. PMID:27354243
Functional Neuroimaging of Speech Perception during a Pivotal Period in Language Acquisition
ERIC Educational Resources Information Center
Redcay, Elizabeth; Haist, Frank; Courchesne, Eric
2008-01-01
A pivotal period in the development of language occurs in the second year of life, when language comprehension undergoes rapid acceleration. However, the brain bases of these advances remain speculative as there is currently no functional magnetic resonance imaging (fMRI) data from healthy, typically developing toddlers at this age. We…
Mitchell, Timothy J.; Hacker, Carl D.; Breshears, Jonathan D.; Szrama, Nick P.; Sharma, Mohit; Bundy, David T.; Pahwa, Mrinal; Corbetta, Maurizio; Snyder, Abraham Z.; Shimony, Joshua S.
2013-01-01
BACKGROUND: Recent findings associated with resting-state cortical networks have provided insight into the brain's organizational structure. In addition to their neuroscientific implications, the networks identified by resting-state functional magnetic resonance imaging (rs-fMRI) may prove useful for clinical brain mapping. OBJECTIVE: To demonstrate that a data-driven approach to analyze resting-state networks (RSNs) is useful in identifying regions classically understood to be eloquent cortex as well as other functional networks. METHODS: This study included 6 patients undergoing surgical treatment for intractable epilepsy and 7 patients undergoing tumor resection. rs-fMRI data were obtained before surgery and 7 canonical RSNs were identified by an artificial neural network algorithm. Of these 7, the motor and language networks were then compared with electrocortical stimulation (ECS) as the gold standard in the epilepsy patients. The sensitivity and specificity for identifying these eloquent sites were calculated at varying thresholds, which yielded receiver-operating characteristic (ROC) curves and their associated area under the curve (AUC). RSNs were plotted in the tumor patients to observe RSN distortions in altered anatomy. RESULTS: The algorithm robustly identified all networks in all patients, including those with distorted anatomy. When all ECS-positive sites were considered for motor and language, rs-fMRI had AUCs of 0.80 and 0.64, respectively. When the ECS-positive sites were analyzed pairwise, rs-fMRI had AUCs of 0.89 and 0.76 for motor and language, respectively. CONCLUSION: A data-driven approach to rs-fMRI may be a new and efficient method for preoperative localization of numerous functional brain regions. ABBREVIATIONS: AUC, area under the curve BA, Brodmann area BOLD, blood oxygen level dependent ECS, electrocortical stimulation fMRI, functional magnetic resonance imaging ICA, independent component analysis MLP, multilayer perceptron MP-RAGE, magnetization-prepared rapid gradient echo ROC, receiver-operating characteristic rs-fMRI, resting-state functional magnetic resonance imaging RSN, resting-state network PMID:24264234
Nanoscale magnetic ratchets based on shape anisotropy
NASA Astrophysics Data System (ADS)
Cui, Jizhai; Keller, Scott M.; Liang, Cheng-Yen; Carman, Gregory P.; Lynch, Christopher S.
2017-02-01
Controlling magnetization using piezoelectric strain through the magnetoelectric effect offers several orders of magnitude reduction in energy consumption for spintronic applications. However strain is a uniaxial effect and, unlike directional magnetic field or spin-polarized current, cannot induce a full 180° reorientation of the magnetization vector when acting alone. We have engineered novel ‘peanut’ and ‘cat-eye’ shaped nanomagnets on piezoelectric substrates that undergo repeated deterministic 180° magnetization rotations in response to individual electric-field-induced strain pulses by breaking the uniaxial symmetry using shape anisotropy. This behavior can be likened to a magnetic ratchet, advancing magnetization clockwise with each piezostrain trigger. The results were validated using micromagnetics implemented in a multiphysics finite elements code to simulate the engineered spatial and temporal magnetic behavior. The engineering principles start from a target device function and proceed to the identification of shapes that produce the desired function. This approach opens a broad design space for next generation magnetoelectric spintronic devices.
Room temperature organic magnets derived from sp3 functionalized graphene.
Tuček, Jiří; Holá, Kateřina; Bourlinos, Athanasios B; Błoński, Piotr; Bakandritsos, Aristides; Ugolotti, Juri; Dubecký, Matúš; Karlický, František; Ranc, Václav; Čépe, Klára; Otyepka, Michal; Zbořil, Radek
2017-02-20
Materials based on metallic elements that have d orbitals and exhibit room temperature magnetism have been known for centuries and applied in a huge range of technologies. Development of room temperature carbon magnets containing exclusively sp orbitals is viewed as great challenge in chemistry, physics, spintronics and materials science. Here we describe a series of room temperature organic magnets prepared by a simple and controllable route based on the substitution of fluorine atoms in fluorographene with hydroxyl groups. Depending on the chemical composition (an F/OH ratio) and sp 3 coverage, these new graphene derivatives show room temperature antiferromagnetic ordering, which has never been observed for any sp-based materials. Such 2D magnets undergo a transition to a ferromagnetic state at low temperatures, showing an extraordinarily high magnetic moment. The developed theoretical model addresses the origin of the room temperature magnetism in terms of sp 2 -conjugated diradical motifs embedded in an sp 3 matrix and superexchange interactions via -OH functionalization.
Room temperature organic magnets derived from sp3 functionalized graphene
Tuček, Jiří; Holá, Kateřina; Bourlinos, Athanasios B.; Błoński, Piotr; Bakandritsos, Aristides; Ugolotti, Juri; Dubecký, Matúš; Karlický, František; Ranc, Václav; Čépe, Klára; Otyepka, Michal; Zbořil, Radek
2017-01-01
Materials based on metallic elements that have d orbitals and exhibit room temperature magnetism have been known for centuries and applied in a huge range of technologies. Development of room temperature carbon magnets containing exclusively sp orbitals is viewed as great challenge in chemistry, physics, spintronics and materials science. Here we describe a series of room temperature organic magnets prepared by a simple and controllable route based on the substitution of fluorine atoms in fluorographene with hydroxyl groups. Depending on the chemical composition (an F/OH ratio) and sp3 coverage, these new graphene derivatives show room temperature antiferromagnetic ordering, which has never been observed for any sp-based materials. Such 2D magnets undergo a transition to a ferromagnetic state at low temperatures, showing an extraordinarily high magnetic moment. The developed theoretical model addresses the origin of the room temperature magnetism in terms of sp2-conjugated diradical motifs embedded in an sp3 matrix and superexchange interactions via –OH functionalization. PMID:28216636
Epilepsy surgery in patients with malformations of cortical development.
Lüders, Hans; Schuele, Stephan U
2006-04-01
Patients with malformations of cortical development often suffer from intractable focal epilepsy. This review considers recent progress in the selection and seizure outcome of patients undergoing resective epilepsy surgery for this condition. Patients with malformations of cortical development restricted to part or even a whole hemisphere may be candidates for epilepsy surgery even when, due to microscopic malformations, magnetic resonance imaging shows no detectable lesion. Despite recent advances in structural and functional imaging, the majority of patients with this condition undergo invasive evaluation. Patients with focal cortical dysplasia, with and without a detectable lesion on magnetic resonance imaging, often have a favorable outcome with epilepsy surgery. The underlying pathological substrate seems to be a better predictor for surgical outcome in patients with focal cortical dysplasia than the presence of a lesion on magnetic resonance imaging. Epilepsy surgery can be offered in a highly selected subgroup of patients with unilateral nodular heterotopia. Seizures in hemimegalencephaly may respond favorably to hemispherectomy, although most children will continue to have seizures and significant functional impairments. Patients with focal epilepsy due to malformations of cortical development are often intractable to medical management. Resective epilepsy surgery can be beneficial, particularly for patients with focal cortical dysplasia and unilateral hemispheric malformations.
Spin dynamics of random Ising chain in coexisting transverse and longitudinal magnetic fields
NASA Astrophysics Data System (ADS)
Liu, Zhong-Qiang; Jiang, Su-Rong; Kong, Xiang-Mu; Xu, Yu-Liang
2017-05-01
The dynamics of the random Ising spin chain in coexisting transverse and longitudinal magnetic fields is studied by the recursion method. Both the spin autocorrelation function and its spectral density are investigated by numerical calculations. It is found that system's dynamical behaviors depend on the deviation σJ of the random exchange coupling between nearest-neighbor spins and the ratio rlt of the longitudinal and the transverse fields: (i) For rlt = 0, the system undergoes two crossovers from N independent spins precessing about the transverse magnetic field to a collective-mode behavior, and then to a central-peak behavior as σJ increases. (ii) For rlt ≠ 0, the system may exhibit a coexistence behavior of a collective-mode one and a central-peak one. When σJ is small (or large enough), system undergoes a crossover from a coexistence behavior (or a disordered behavior) to a central-peak behavior as rlt increases. (iii) Increasing σJ depresses effects of both the transverse and the longitudinal magnetic fields. (iv) Quantum random Ising chain in coexisting magnetic fields may exhibit under-damping and critical-damping characteristics simultaneously. These results indicate that changing the external magnetic fields may control and manipulate the dynamics of the random Ising chain.
Age-Related Variability in Cortical Activity during Language Processing
ERIC Educational Resources Information Center
Fridriksson, Julius; Morrow, K. Leigh; Moser, Dana; Baylis, Gordon C.
2006-01-01
Purpose: The present study investigated the extent of cortical activity during overt picture naming using functional magnetic resonance imaging (fMRI). Method: Participants comprised 20 healthy, adult participants with ages ranging from 20 to 82 years. While undergoing fMRI, participants completed a picture-naming task consisting of 60…
A free boundary approach to the Rosensweig instability of ferrofluids
NASA Astrophysics Data System (ADS)
Parini, Enea; Stylianou, Athanasios
2018-04-01
We establish the existence of saddle points for a free boundary problem describing the two-dimensional free surface of a ferrofluid undergoing normal field instability. The starting point is the ferrohydrostatic equations for the magnetic potentials in the ferrofluid and air, and the function describing their interface. These constitute the strong form for the Euler-Lagrange equations of a convex-concave functional, which we extend to include interfaces that are not necessarily graphs of functions. Saddle points are then found by iterating the direct method of the calculus of variations and applying classical results of convex analysis. For the existence part, we assume a general nonlinear magnetization law; for a linear law, we also show, via convex duality, that the saddle point is a constrained minimizer of the relevant energy functional.
Exchange bias in bulk layered hydroxylammonium fluorocobaltate (NH₃OH)₂CoF₄.
Jagličić, Z; Zentková, M; Mihalik, M; Arnold, Z; Drofenik, M; Kristl, M; Dojer, B; Kasunič, M; Golobič, A; Jagodič, M
2012-02-08
The magnetic properties of layered hydroxylammonium fluorocobaltate (NH(3)OH)(2)CoF(4) were investigated by measuring its dc magnetic susceptibility in zero-field-cooled (ZFC) and field-cooled (FC) regimes, its frequency dependent ac susceptibility, its isothermal magnetization curves after ZFC and FC regimes, and its heat capacity. Effects of pressure and magnetic field on magnetic phase transitions were studied by susceptibility and heat capacity measurements, respectively. The system undergoes a magnetic phase transition from a paramagnetic state to a canted antiferromagnetic state exhibiting a weak ferromagnetic behavior at T(C) = 46.5 K and an antiferromagnetic transition at T(N) = 2.9 K. The most spectacular manifestation of the complex magnetic behavior in this system is a shift of the isothermal magnetization hysteresis loop in a temperature range below 20 K after the FC regime-an exchange bias phenomenon. We investigated the exchange bias as a function of the magnetic field during cooling and as a function of temperature. The observed exchange bias was attributed to the large exchange anisotropy which exists due to the quasi-2D structure of the layered (NH(3)OH)(2)CoF(4) material.
Optical head tracking for functional magnetic resonance imaging using structured light.
Zaremba, Andrei A; MacFarlane, Duncan L; Tseng, Wei-Che; Stark, Andrew J; Briggs, Richard W; Gopinath, Kaundinya S; Cheshkov, Sergey; White, Keith D
2008-07-01
An accurate motion-tracking technique is needed to compensate for subject motion during functional magnetic resonance imaging (fMRI) procedures. Here, a novel approach to motion metrology is discussed. A structured light pattern specifically coded for digital signal processing is positioned onto a fiduciary of the patient. As the patient undergoes spatial transformations in 6 DoF (degrees of freedom), a high-resolution CCD camera captures successive images for analysis on a computing platform. A high-speed image processing algorithm is used to calculate spatial transformations in a time frame commensurate with patient movements (10-100 ms) and with a precision of at least 0.5 microm for translations and 0.1 deg for rotations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huang, Jingsong; Sumpter, Bobby G; Meunier, Vincent
2010-01-01
Cyclo-biphenalenyl biradicaloid molecular materials with chair- and boat-conformations are studied by restricted and broken-symmetry DFT using the M06 family of meta-GGA functionals. The global minima of these molecular materials are magnetically silent due to the sigma-bond connecting the two phenalenyls, while the sigma-bond may undergo low-barrier sigmatropic rearrangements via pi-pi bonded paramagnetic intermediates. The validation of theory is performed for the chair-conformation by comparing the sigma-bonded structures and the rearrangement barriers with experimental data. The boat-conformation is then studied using the validated functional. The electronic spectra of both chair- and boat-conformations are calculated and their applications in thermochromism are discussed.
Missios, Symeon; Bekelis, Kimon
2018-03-01
The association of Magnet hospital status with improved surgical outcomes remains an issue of debate. To investigate whether hospitalization in a Magnet hospital is associated with improved outcomes for patients undergoing neurosurgical operations. A cohort study was executed using all patients undergoing neurosurgical operations in New York registered in the Statewide Planning and Research Cooperative System database from 2009 to 2013. We examined the association of Magnet status hospitalization after neurosurgical operations with inpatient case fatality and length of stay (LOS). We employed an instrumental variable analysis to simulate a randomized trial. Overall, 190 787 patients underwent neurosurgical operations. Of these, 68 046 (35.7%) were hospitalized in Magnet hospitals, and 122 741 (64.3%) in non-Magnet institutions. Instrumental variable analysis demonstrated that hospitalization in Magnet hospitals was associated with decreased case fatality (adjusted difference, -0.8%; -95% confidence interval, -0.7% to -0.6%), and LOS (adjusted difference, -1.9; 95% confidence interval, -2.2 to -1.5) in comparison to non-Magnet hospitals. These associations were also observed in propensity score adjusted mixed effects models. These associations persisted in prespecified subgroups of patients undergoing spine surgery, craniotomy for tumor resection, or neurovascular interventions. We identified an association of Magnet hospitals with lower case fatality, and shorter LOS in a comprehensive New York State patient cohort undergoing neurosurgical procedures. Copyright © 2017 by the Congress of Neurological Surgeons
Gadolinium-based magnetic resonance imaging contrast agents in interventional radiology.
Atar, Eli
2004-07-01
Gadolinium-based agents are widely used in magnetic resonance imaging as contrast agents. These agents are radio-opaque enough for diagnostic imaging of the vascular tree by using digitally subtracted images as well as for imaging of the biliary system and the urinary tract. The recommended doses for gadolinium do not impair renal function or cause adverse reactions in patients with iodine sensitivity; thus patients with such conditions can safely undergo diagnostic angiography, either by MRI angiography or by catheterization using gadolinium as contrast agent, for diagnostic and therapeutic purposes.
Bridgman Growth of Germanium Crystals in a Rotating Magnetic Field
NASA Technical Reports Server (NTRS)
Volz, M. P.; Schweizer, M.; Cobb, S. D.; Walker, J. S.; Szofran, F. R.; Curreri, Peter A. (Technical Monitor)
2002-01-01
A series of (100)-oriented gallium-doped germanium crystals have been grown by the Bridgman method and under the influence of a rotating magnetic field (RMF). The RMF has a marked affect on the interface shape, changing it from concave to nearly flat. The onset of time-dependent flow instabilities occurs when the critical magnetic Taylor number is exceeded, and this can be observed by noting the appearance of striations in the grown crystals. The critical magnetic Taylor number is a sensitive function of the aspect ratio and, as the crystal grows under a constant applied magnetic field, the induced striations change from nonperiodic to periodic, undergo a period-doubling transition, and then cease to exist. Also, by pulsing the RMF on and off, it is shown that intentional interface demarcations can be introduced.
Magnetic stripe domains of [Pt/Co/Cu]{sub 10} multilayer near spin reorientation transition
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sun, L.; Liang, J. H.; Xiao, X.
The dependence of magnetic anisotropy, magnetic domain patterns and magnetization reversal processes in [Pt/Co(t{sub Co})/Cu]{sub 10} film stack epitaxied on Cu (111) substrate have been studied as a function of the Co layer thickness t{sub Co}, by magneto-optic polar Kerr magnetometry and microscopy. We find the film undergoes spin reorientation transition from out-of-plane to in-plane as t{sub Co} increases. The SRT thickness is verified by Rotating-field Magneto-Optic Kerr effect method. The film exhibits the stripe domain structures at remanence with the width decreasing while t{sub Co} approaches SRT. As demonstrated by the first order reversal curve measurement, the magnetization reversalmore » process encompasses irreversible domain nucleation, domain annihilation at large field and reversible domain switching near remanence.« less
Hale, Matthew D; Zaman, Arshad; Morrall, Matthew C H J; Chumas, Paul; Maguire, Melissa J
2018-03-01
Presurgical evaluation for temporal lobe epilepsy routinely assesses speech and memory lateralization and anatomic localization of the motor and visual areas but not baseline musical processing. This is paramount in a musician. Although validated tools exist to assess musical ability, there are no reported functional magnetic resonance imaging (fMRI) paradigms to assess musical processing. We examined the utility of a novel fMRI paradigm in an 18-year-old left-handed pianist who underwent surgery for a left temporal low-grade ganglioglioma. Preoperative evaluation consisted of neuropsychological evaluation, T1-weighted and T2-weighted magnetic resonance imaging, and fMRI. Auditory blood oxygen level-dependent fMRI was performed using a dedicated auditory scanning sequence. Three separate auditory investigations were conducted: listening to, humming, and thinking about a musical piece. All auditory fMRI paradigms activated the primary auditory cortex with varying degrees of auditory lateralization. Thinking about the piece additionally activated the primary visual cortices (bilaterally) and right dorsolateral prefrontal cortex. Humming demonstrated left-sided predominance of auditory cortex activation with activity observed in close proximity to the tumor. This study demonstrated an fMRI paradigm for evaluating musical processing that could form part of preoperative assessment for patients undergoing temporal lobe surgery for epilepsy. Copyright © 2017 Elsevier Inc. All rights reserved.
Organic-dye-coupled magnetic nanoparticles encaged inside thermoresponsive PNIPAM Microcapsules.
Guo, Jia; Yang, Wuli; Deng, Yonghui; Wang, Changchun; Fu, Shoukuan
2005-07-01
We present a new approach for the fabrication of thermoresponsive polymer microcapsules with mobile magnetic cores that undergo a volume phase-transition upon changing the temperature and are collected under an external magnetic field. We have prepared organic/inorganic composite microspheres with a well-defined core-shell structure that are composed of a crosslinked poly(N-isopropylacrylamide) (PNIPAM) shell and silica cores dotted centrally by magnetite nanoparticles. Since the infiltration of template-decomposed products is dependent on the permeability of PNIPAM shells triggered by changes of exterior temperature, the silica layer sandwiched between the magnetic core and the PNIPAM shell was quantitatively removed to generate PNIPAM microcapsules with mobile magnetic cores by treatment with aqueous NaOH solution. For development of the desired multifunctional microcapsules, modification of the unetched silica surface interiors can be realized by treatment with a silane coupling agent containing functional groups that can easily bind to catalysts, enzymes, or labeling molecules. Herein, fluorescein isothiocyanate (FITC), which is a common organic dye, is attached to the insides of the mobile magnetic cores to give PNIPAM microcapsules with FITC-labeled magnetic cores. In this system, it can be expected that an extension of the functionalization of the cavity properties of smart polymer microcapsules is to immobilize other target molecules onto the mobile cores in order to introduce other desired functions in the hollow cage.
Missios, Symeon; Bekelis, Kimon
2017-01-01
Background The association of Magnet hospital status with improved surgical outcomes remains an issue of debate. Objective To investigate whether hospitalization in a Magnet hospital is associated with improved outcomes for patients undergoing neurosurgical operations. Methods A cohort study was executed using all patients undergoing neurosurgical operations in New York registered in the Statewide Planning and Research Cooperative System (SPARCS) database from 2009–2013. We examined the association of Magnet status hospitalization after neurosurgical operations with inpatient case-fatality, and length of stay (LOS). We employed an instrumental variable analysis to simulate a randomized trial. Results Overall, 190,787 patients underwent neurosurgical operations. Of these, 68,046 (35.7%) were hospitalized in Magnet hospitals, and 122,741 (64.3%) in non-Magnet institutions. Instrumental variable analysis demonstrated that hospitalization in Magnet hospitals was associated with decreased case-fatality (Adjusted difference, −0.8%; −95% CI, −0.7% to −0.6%), and LOS (Adjusted difference, −1.9; 95% CI, −2.2 to −1.5) in comparison to non-Magnet hospitals. These associations were also observed in propensity score adjusted mixed effects models. These associations persisted in pre-specified subgroups of patients undergoing spine surgery, craniotomy for tumor resection, or neurovascular interventions. Conclusions We identified an association of Magnet hospitals with lower case-fatality, and shorter LOS in a comprehensive New York State patient cohort undergoing neurosurgical procedures. PMID:28472336
The effect of magnetic nanoparticle concentration on the structure organisation of a microferrogel
NASA Astrophysics Data System (ADS)
Ryzhkov, A. V.; Melenev, P. V.; Balasoiu, M.; Raikher, Yu L.
2018-03-01
Coarse-grained molecular dynamics simulation is applied to study the structural response of micro-sized magnetopolymer objects – microferrogels (MFG). The results for MFGs with different magnetic properties and concentrations of magnetic filler nanoparticles are analysed to detect the transition between non-aggregated configurations and the states with pronounced chains. The nanoparticles are assumed to be either magnetically isotropic or to possess infinite magnetic anisotropy. It is shown that, depending on the type of the particle anisotropy, an applied field in rather different ways affects the MFG structure and shape. Diagrams describing the degree of aggregation as a function of the parameter of the interparticle magnetodipolar interaction and concentration are presented. In particular, it is found that in the case of infinitely anisotropic nanoparticles the aggregation transitions undergoes via a non-trivial scenario. The effect of the structure transformations on the volume change of the MFG objects is studied as well.
Zhang, Yajun; Sahoo, Mpk; Wang, Jie
2016-09-23
Single vacancy (SV)-induced magnetism in graphene has attracted much attention motivated by its potential in achieving new functionalities. However, a much higher vacancy formation energy limits its direct application in electronic devices and the dependency of spin interaction on the strain is unclear. Here, through first-principles density-functional theory calculations, we investigate the possibility of strain engineering towards lowering vacancy formation energy and inducing new magnetic states in defective graphene. It is found that the SV-graphene undergoes a phase transition from an initial ferromagnetic state to a ferrimagnetic state under a biaxial tensile strain. At the same time, the biaxial tensile strain significantly lowers the vacancy formation energy. The charge density, density of states and band theory successfully identify the origin and underlying physics of the transition. The predicted magnetic phase transition is attributed to the strain driven spin flipping at the C-atoms nearest to the SV-site. The magnetic semiconducting graphene induced by defect and strain engineering suggests an effective way to modulate both spin and electronic degrees of freedom in future spintronic devices.
Nematicity and magnetism in LaFeAsO single crystals probed by 75As nuclear magnetic resonance
NASA Astrophysics Data System (ADS)
Ok, J. M.; Baek, S.-H.; Efremov, D. V.; Kappenberger, R.; Aswartham, S.; Kim, J. S.; van den Brink, Jeroen; Büchner, B.
2018-05-01
We report a 75As nuclear magnetic resonance study in LaFeAsO single crystals, which undergoes nematic and antiferromagnetic transitions at Tnem˜156 K and TN˜138 K, respectively. Below Tnem, the 75As spectrum splits sharply into two for an external magnetic field parallel to the orthorhombic a or b axis in the FeAs planes. Our analysis of the data demonstrates that the NMR line splitting arises from an electronically driven rotational symmetry breaking. The 75As spin-lattice relaxation rate as a function of temperature shows that spin fluctuations are strongly enhanced just below Tnem. These NMR findings indicate that nematic order promotes spin fluctuations in magnetically ordered LaFeAsO, as observed in nonmagnetic and superconducting FeSe. We conclude that the origin of nematicity is identical in both FeSe and LaFeAsO regardless of whether or not a long-range magnetic order develops in the nematic state.
77 FR 45342 - Maxfield and Oberton Holdings, LLC; Complaint
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-31
..., including x-rays and monitoring for infection and internal damage. 27. Since March 2009 to approximately... had to undergo x-rays, CT scans, endoscopy, and an appendectomy to remove them. The girl's father had... attraction of the magnets to the metal equipment used to retrieve the magnets. 22. Children who undergo...
Impact of compressibility and a guide field on Fermi acceleration during magnetic island coalescence
NASA Astrophysics Data System (ADS)
Montag, P.; Egedal, J.; Lichko, E.; Wetherton, B.
2017-06-01
Previous work has shown that Fermi acceleration can be an effective heating mechanism during magnetic island coalescence, where electrons may undergo repeated reflections as the magnetic field lines contract. This energization has the potential to account for the power-law distributions of particle energy inferred from observations of solar flares. Here, we develop a generalized framework for the analysis of Fermi acceleration that can incorporate the effects of compressibility and non-uniformity along field lines, which have commonly been neglected in previous treatments of the problem. Applying this framework to the simplified case of the uniform flux tube allows us to find both the power-law scaling of the distribution function and the rate at which the power-law behavior develops. We find that a guide magnetic field of order unity effectively suppresses the development of power-law distributions.
Yücel, Meryem A.; Steele, Sarah C.; Alexander, Mark E.; Boas, David A.; Borsook, David; Becerra, Lino
2016-01-01
The predictability of pain makes surgery an ideal model for the study of pain and the development of strategies for analgesia and reduction of perioperative pain. As functional near-infrared spectroscopy reproduces the known functional magnetic resonance imaging activations in response to a painful stimulus, we evaluated the feasibility of functional near-infrared spectroscopy to measure cortical responses to noxious stimulation during general anesthesia. A multichannel continuous wave near-infrared imager was used to measure somatosensory and frontal cortical activation in patients undergoing catheter ablation of arrhythmias under general anesthesia. Anesthetic technique was standardized and intraoperative NIRS signals recorded continuously with markers placed in the data set for the timing and duration of each cardiac ablation event. Frontal cortical signals only were suitable for analysis in five of eight patients studied (mean age 14 ± 1 years, weight 66.7 ± 17.6 kg, 2 males). Thirty ablative lesions were recorded for the five patients. Radiofrequency or cryoablation was temporally associated with a hemodynamic response function in the frontal cortex characterized by a significant decrease in oxyhemoglobin concentration (paired t-test, p<0.05) with the nadir occurring in the period 4 to 6 seconds after application of the ablative lesion. Cortical signals produced by catheter ablation of arrhythmias in patients under general anesthesia mirrored those seen with noxious stimulation in awake, healthy volunteers, during sedation for colonoscopy, and functional Magnetic Resonance Imaging activations in response to pain. This study demonstrates the feasibility and potential utility of functional near-infrared spectroscopy as an objective measure of cortical activation under general anesthesia. PMID:27415436
Kussman, Barry D; Aasted, Christopher M; Yücel, Meryem A; Steele, Sarah C; Alexander, Mark E; Boas, David A; Borsook, David; Becerra, Lino
2016-01-01
The predictability of pain makes surgery an ideal model for the study of pain and the development of strategies for analgesia and reduction of perioperative pain. As functional near-infrared spectroscopy reproduces the known functional magnetic resonance imaging activations in response to a painful stimulus, we evaluated the feasibility of functional near-infrared spectroscopy to measure cortical responses to noxious stimulation during general anesthesia. A multichannel continuous wave near-infrared imager was used to measure somatosensory and frontal cortical activation in patients undergoing catheter ablation of arrhythmias under general anesthesia. Anesthetic technique was standardized and intraoperative NIRS signals recorded continuously with markers placed in the data set for the timing and duration of each cardiac ablation event. Frontal cortical signals only were suitable for analysis in five of eight patients studied (mean age 14 ± 1 years, weight 66.7 ± 17.6 kg, 2 males). Thirty ablative lesions were recorded for the five patients. Radiofrequency or cryoablation was temporally associated with a hemodynamic response function in the frontal cortex characterized by a significant decrease in oxyhemoglobin concentration (paired t-test, p<0.05) with the nadir occurring in the period 4 to 6 seconds after application of the ablative lesion. Cortical signals produced by catheter ablation of arrhythmias in patients under general anesthesia mirrored those seen with noxious stimulation in awake, healthy volunteers, during sedation for colonoscopy, and functional Magnetic Resonance Imaging activations in response to pain. This study demonstrates the feasibility and potential utility of functional near-infrared spectroscopy as an objective measure of cortical activation under general anesthesia.
Periyasamy, M.; Dhanasekaran, R.
2014-01-01
The objective of this study was to evaluate two issues regarding magnetic resonance imaging (MRI) including device functionality and image artifacts for the presence of radio frequency identification devices (RFID) in association with 0.3 Tesla at 12.7 MHz MRI and computed tomography (CT) scanning. Fifteen samples of RFID tags with two different sizes (wristband and ID card types) were tested. The tags were exposed to several MR-imaging conditions during MRI examination and X-rays of CT scan. Throughout the test, the tags were oriented in three different directions (axial, coronal, and sagittal) relative to MRI system in order to cover all possible situations with respect to the patient undergoing MRI and CT scanning, wearing a RFID tag on wrist. We observed that the tags did not sustain physical damage with their functionality remaining unaffected even after MRI and CT scanning, and there was no alternation in previously stored data as well. In addition, no evidence of either signal loss or artifact was seen in the acquired MR and CT images. Therefore, we can conclude that the use of this passive RFID tag is safe for a patient undergoing MRI at 0.3 T/12.7 MHz and CT Scanning. PMID:24701187
BETA (Bitter Electromagnet Testing Apparatus) Design and Testing
NASA Astrophysics Data System (ADS)
Bates, Evan; Birmingham, William; Rivera, William; Romero-Talamas, Carlos
2016-10-01
BETA is a 1T water cooled Bitter-type magnetic system that has been designed and constructed at the Dusty Plasma Laboratory of the University of Maryland, Baltimore County to serve as a prototype of a scaled 10T version. Currently the system is undergoing magnetic, thermal and mechanical testing to ensure safe operating conditions and to prove analytical design optimizations. These magnets will function as experimental tools for future dusty plasma based and collaborative experiments. An overview of design methods used for building a custom made Bitter magnet with user defined experimental constraints is reviewed. The three main design methods consist of minimizing the following: ohmic power, peak conductor temperatures, and stresses induced by Lorentz forces. We will also discuss the design of BETA which includes: the magnet core, pressure vessel, cooling system, power storage bank, high powered switching system, diagnostics with safety cutoff feedback, and data acquisition (DAQ)/magnet control Matlab code. Furthermore, we present experimental data from diagnostics for validation of our analytical preliminary design methodologies and finite element analysis calculations. BETA will contribute to the knowledge necessary to finalize the 10 T magnet design.
Quantum transitions driven by one-bond defects in quantum Ising rings.
Campostrini, Massimo; Pelissetto, Andrea; Vicari, Ettore
2015-04-01
We investigate quantum scaling phenomena driven by lower-dimensional defects in quantum Ising-like models. We consider quantum Ising rings in the presence of a bond defect. In the ordered phase, the system undergoes a quantum transition driven by the bond defect between a magnet phase, in which the gap decreases exponentially with increasing size, and a kink phase, in which the gap decreases instead with a power of the size. Close to the transition, the system shows a universal scaling behavior, which we characterize by computing, either analytically or numerically, scaling functions for the low-level energy differences and the two-point correlation function. We discuss the implications of these results for the nonequilibrium dynamics in the presence of a slowly varying parallel magnetic field h, when going across the first-order quantum transition at h=0.
NASA Technical Reports Server (NTRS)
Elphic, R. C.; Gary, S. P.
1990-01-01
This paper describes ISEE plasma and magnetic fluctuation observations during two crossings of the plasma sheet boundary layer (PSBL) in the earth's magnetotail. Distribution function observations show that the counterstreaming ion components undergo pitch-angle scattering and evolve into a shell distribution in velocity space. This evolution is correlated with the development of low frequency, low amplitude magnetic fluctuations. However, the measured wave amplitudes are insufficient to accomplish the observed degree of ion pitch-angle scatttering locally; the near-earth distributions may be the result of processes occurring much farther down the magnetotail. Results show a clear correlation between the ion component beta and the relative streaming speed of the two components, suggesting that electromagnetic ion/ion instabilities do play an important role in the scattering of PSBL ions.
Grover, Helen J; Thornton, Rachel; Lutchman, Lennel N; Blake, Julian C
2016-06-01
The authors report a case of unilateral loss of intraoperative transcranial electrical motor evoked potentials (TES MEP) associated with a spinal cord injury during scoliosis correction and the subsequent use of extraoperative transcranial magnetic stimulation to monitor the recovery of spinal cord function. The authors demonstrate the absence of TES MEPs and absent transcranial magnetic stimulation responses in the immediate postoperative period, and document the partial recovery of transcranial magnetic stimulation responses, which corresponded to partial recovery of TES MEPs. Intraoperative TES MEPs were enhanced using spatial facilitation technique, which enabled the patient to undergo further surgery to stabilize the spine and correct her scoliosis. This case report supports evidence of the use of extraoperative transcranial magnetic stimulation to predict the presence of intraoperative TES responses and demonstrates the usefulness of spatial facilitation to monitor TES MEPs in a patient with a preexisting spinal cord injury.
Visualizing Transcranial Direct Current Stimulation (tDCS) in vivo using Magnetic Resonance Imaging
NASA Astrophysics Data System (ADS)
Jog, Mayank Anant
Transcranial Direct Current Stimulation (tDCS) is a low-cost, non-invasive neuromodulation technique that has been shown to treat clinical symptoms as well as improve cognition. However, no techniques exist at the time of research to visualize tDCS currents in vivo. This dissertation presents the theoretical framework and experimental implementations of a novel MRI technique that enables non-invasive visualization of the tDCS electric current using magnetic field mapping. The first chapter establishes the feasibility of measuring magnetic fields induced by tDCS currents. The following chapter discusses the state of the art implementation that can measure magnetic field changes in individual subjects undergoing concurrent tDCS/MRI. The final chapter discusses how the developed technique was integrated with BOLD fMRI-an established MRI technique for measuring brain function. By enabling a concurrent measurement of the tDCS current induced magnetic field as well as the brain's hemodynamic response to tDCS, our technique opens a new avenue to investigate tDCS mechanisms and improve targeting.
Physical realization of a quantum spin liquid based on a complex frustration mechanism
NASA Astrophysics Data System (ADS)
Reuther, Johannes; Balz, Christian; Lake, Bella
Unlike conventional magnets where the spins undergo magnetic long-range order in the ground state, in a quantum spin liquid they remain disordered down to the lowest temperatures without breaking local symmetries. Here, we investigate the novel, unexplored bilayer-kagome magnet Ca10Cr7O28, which has a complex Hamiltonian consisting of isotropic antiferromagnetic and ferromagnetic interactions where the ferromagnetic couplings are the dominant ones. We show both experimentally and theoretically that this compound displays all the features expected of a quantum spin liquid. In particular, experiments rule out static magnetic order down to 19mK and reveal a diffuse spinon-like excitation spectrum. Numerically simulating this material using the pseudo fermion functional renormalization group (PFFRG) method, we theoretically confirm the non-magnetic ground state of the system and qualitatively reproduce the measured spin correlation profile. By tuning the model parameters away from those realized in Ca10Cr7O28 we further show that the spin-liquid phase is of remarkable stability.
Magnetically-induced electric polarization in an organo-metallic magnet
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zapf, W S; Fabris, F W; Balakirev, F F
2009-01-01
The coupling between magnetic order and ferroelectricity has been under intense investigation in a wide range of transition metal oxides. The strongest coupling is obtained in so-called magnetically induced multiferroics where ferroelectricity arises directly from magnetic order that breaks inversion symmetry. However, it has been difficult to find non-oxide based materials in which these effects occur. Here we present a study of copper dimethyl sulfoxide dichloride (CDC), an organometallic quantum magnet containing S =1/1 Cu spins, in which a switchable electric polarization arises from field-tuned magnetic order. Fast magnetic field pulses allow us to perform sensitive measurements of the electricmore » polarization and demonstrate that the electric state is present only if the magnetic order is non-collinear. Furthermore, we show that the electric polarization can be switched in a stunning hysteretic fashion. Because the magnetic order in CDC is mediated by large organic molecules, our study shows that magnetoelectric interactions can exist in this important class of materials, opening the road to designing magnetoelectrics and multiferroics using large molecules as building blocks. Further, we demonstrate that CDC undergoes a magnetoelectric quantum phase transition -the first of its kind, where both ferroelectric and magnetic order emerge simultaneously as a function of magnetic field at very low temperatures.« less
Evaluation of MRI issues for an access port with a radiofrequency identification (RFID) tag.
Titterington, Blake; Shellock, Frank G
2013-10-01
A medical implant that contains metal, such as an RFID tag, must undergo proper MRI testing to ensure patient safety and to determine that the function of the RFID tag is not compromised by exposure to MRI conditions. Therefore, the objective of this investigation was to assess MRI issues for a new access port that incorporates an RFID tag. Samples of the access port with an RFID tag (Medcomp Power Injectable Port with CertainID; Medcomp, Harleysville, PA) were evaluated using standard protocols to assess magnetic field interactions (translational attraction and torque; 3-T), MRI-related heating (3-T), artifacts (3-T), and functional changes associated with different MRI conditions (nine samples, exposed to different MRI conditions at 1.5-T and 3-T). Magnetic field interactions were not substantial and will pose no hazards to patients. MRI-related heating was minimal (highest temperature change, 1.7°C; background temperature rise, 1.6°C). Artifacts were moderate in size in relation to the device. Exposures to MRI conditions at 1.5-T and 3-T did not alter or damage the functional aspects of the RFID tag. Based on the findings of the test, this new access port with an RFID tag is acceptable (or, MR conditional, using current MRI labeling terminology) for patients undergoing MRI examinations at 1.5-T/64-MHz and 3-T/128-MHz. Copyright © 2013 Elsevier Inc. All rights reserved.
Jiang, Ming-Ming; Zhou, Qing; Liu, Xiao-Yong; Shi, Chang-Zheng; Chen, Jian; Huang, Xiang-He
2017-03-01
To investigate structural and functional brain changes in patients with primary open-angle glaucoma (POAG) by using voxel-based morphometry based on diffeomorphic anatomical registration through exponentiated Lie algebra (VBM-DARTEL) and blood oxygenation level dependent functional magnetic resonance imaging (BOLD-fMRI), respectively.Thirteen patients diagnosed with POAG and 13 age- and sex-matched healthy controls were enrolled in the study. For each participant, high-resolution structural brain imaging and blood flow imaging were acquired on a 3.0-Tesla magnetic resonance imaging (MRI) scanner. Structural and functional changes between the POAG and control groups were analyzed. An analysis was carried out to identify correlations between structural and functional changes acquired in the previous analysis and the retinal nerve fiber layer (RNFL).Patients in the POAG group showed a significant (P < 0.001) volume increase in the midbrain, left brainstem, frontal gyrus, cerebellar vermis, left inferior parietal lobule, caudate nucleus, thalamus, precuneus, and Brodmann areas 7, 18, and 46. Moreover, significant (P < 0.001) BOLD signal changes were observed in the right supramarginal gyrus, frontal gyrus, superior frontal gyrus, left inferior parietal lobule, left cuneus, and left midcingulate area; many of these regions had high correlations with the RNFL.Patients with POAG undergo widespread and complex changes in cortical brain structure and blood flow. (ClinicalTrials.gov number: NCT02570867).
Facile transformation of FeO/Fe3O4 core-shell nanocubes to Fe3O4 via magnetic stimulation
NASA Astrophysics Data System (ADS)
Lak, Aidin; Niculaes, Dina; Anyfantis, George C.; Bertoni, Giovanni; Barthel, Markus J.; Marras, Sergio; Cassani, Marco; Nitti, Simone; Athanassiou, Athanassia; Giannini, Cinzia; Pellegrino, Teresa
2016-09-01
Here, we propose the use of magnetic hyperthermia as a means to trigger the oxidation of Fe1-xO/Fe3-δO4 core-shell nanocubes to Fe3-δO4 phase. As a first relevant consequence, the specific absorption rate (SAR) of the initial core-shell nanocubes doubles after exposure to 25 cycles of alternating magnetic field stimulation. The improved SAR value was attributed to a gradual transformation of the Fe1-xO core to Fe3-δO4, as evidenced by structural analysis including high resolution electron microscopy and Rietveld analysis of X-ray diffraction patterns. The magnetically oxidized nanocubes, having large and coherent Fe3-δO4 domains, reveal high saturation magnetization and behave superparamagnetically at room temperature. In comparison, the treatment of the same starting core-shell nanocubes by commonly used thermal annealing process renders a transformation to γ-Fe2O3. In contrast to other thermal annealing processes, the method here presented has the advantage of promoting the oxidation at a macroscopic temperature below 37 °C. Using this soft oxidation process, we demonstrate that biotin-functionalized core-shell nanocubes can undergo a mild self-oxidation transformation without losing their functional molecular binding activity.
Optimization of Ballast Design: A Case Study of the Physics Entrepreneurship Program
NASA Astrophysics Data System (ADS)
Ding, Jun; Cheng, Norman; Lamouri, Abbas; Sulcs, Juris; Brown, Robert; Taylor, Cyrus
2001-10-01
This talk presents a typical internship project for students in the Physics Entrepreneurship Program at Case Western Reserve University. As part of their overall strategy, Advanced Lighting International (ADLT) is involved in the production of magnetic ballasts for metal halide lamps. The systems in which these ballasts function is undergoing rapid evolution, leading to the question of how the design of the ballasts can be optimized in order to deliver superior performance for lower cost. Addressing this question requires a full understanding of a variety of issues ranging from the basic modeling of the physics of the magnetic ballasts to questions of overall market strategy, manufacturing considerations, and the competitive environment.
NASA Astrophysics Data System (ADS)
Tomiya, Akio; Ding, Heng-Tong; Mukherjee, Swagato; Schmidt, Christian; Wang, Xiao-Dan
2018-03-01
Lattice simulations for (2+1)-flavor QCD with external magnetic field demon-strated that the quark mass is one of the important parameters responsible for the (inverse) magnetic catalysis. We discuss the dependences of chiral condensates and susceptibilities, the Polyakov loop on the magnetic field and quark mass in three degenerate flavor QCD. The lattice simulations are performed using standard staggered fermions and the plaquette action with spatial sizes Nσ = 16 and 24 and a fixed temporal size Nτ = 4. The value of the quark masses are chosen such that the system undergoes a first order chiral phase transition and crossover with zero magnetic field. We find that in light mass regime, the quark chiral condensate undergoes magnetic catalysis in the whole temperature region and the phase transition tend to become stronger as the magnetic field increases. In crossover regime, deconfinement transition temperature is shifted by the magnetic field when quark mass ma is less than 0:4. The lattice cutoff effects are also discussed.
Joshi, Subodh B; Roswell, Robert O; Salah, Ali K; Zeman, Peter R; Corso, Paul J; Lindsay, Joseph; Fuisz, Anthon R
2010-01-01
A reduction in right ventricular function commonly occurs in the early postoperative period after coronary artery bypass graft surgery (CABG). We sought to determine the longer-term effect of CABG on right ventricular function. Cardiac magnetic resonance imaging was performed before and approximately 3 months after surgery in 28 patients undergoing elective CABG. Right ventricular (RV) ejection fraction was assessed by planimetry of electrocardiographically gated cine images. There was a statistically significant increase in left ventricular ejection fraction from 50% to 58% (P=.003) after CABG. RV ejection fraction also increased from 54% to 60% (P=.002). In patients with lower baseline RV ejection fraction (below the median, < 53%), this parameter improved from 47% to 57% (P<.001). Both on-pump (47% vs. 62%, P=.003) as well as off-pump CABG (47% vs. 55%, P=.009) lead to an improvement in RV function in patients in the initial low RV ejection fraction group. Long-term right ventricular function was not adversely affected by CABG. An improvement in RV function occurred after surgery in patients with low baseline RV ejection fraction and was similar in patients who underwent surgery with or without cardiopulmonary bypass.
Magnetic Frequency Response of HL-LHC Beam Screens
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morrone, M.; Martino, M.; De Maria, R.
Magnetic fields used to control particle beams in accelerators are usually controlled by regulating the electrical current of the power converters. In order to minimize lifetime degradation and ultimately luminosity loss in circular colliders, current-noise is a highly critical figure of merit of power converters, in particular for magnets located in areas with high beta-function, like the High Luminosity Large Hadron Collider (HL-LHC) insertions. However, what is directly acting upon the beam is the magnetic field and not the current of the power converter, which undergoes several frequency-dependent transformations until the desired magnetic field, seen by the beam, is obtained.more » Beam screens are very rarely considered when assessing or specifying the noise figure of merit, but their magnetic frequency response is such that they realize relatively effective low pass filtering of the magnetic field produced by the system magnet-power converter. This work aims at filling this gap by quantifying the expected impact of different beam screen layouts for the most relevant HL-LHC insertion magnets. A welldefined post-processing technique is used to derive the frequency response of the different multipoles from multi-physics Finite Element Method (FEM) simulation results. In addition, a well approximated analytical formula for the low-frequency range of multi-layered beam screens is presented.« less
Stochastic particle acceleration at shocks in the presence of braided magnetic fields.
NASA Astrophysics Data System (ADS)
Kirk, J. G.; Duffy, P.; Gallant, Y. A.
1996-10-01
The theory of diffusive acceleration of energetic particles at shock fronts assumes charged particles undergo spatial diffusion in a uniform magnetic field. If, however, the magnetic field is not uniform, but has a stochastic or braided structure, the transport of charged particles across the average direction of the field is more complicated. Assuming quasi-linear behaviour of the field lines, the particles undergo sub-diffusion on short time scales. We derive the propagator for such motion, which differs from the Gaussian form relevant for diffusion, and apply it to a configuration with a plane shock front whose normal is perpendicular to the average field direction. Expressions are given for the acceleration time as a function of the diffusion coefficient of the wandering magnetic field lines and the spatial diffusion coefficient of the charged particles parallel to the local field. In addition we calculate the spatial dependence of the particle density in both the upstream and downstream plasmas. In contrast to the diffusive case, the density of particles at the shock front is lower than it is far downstream. This is a consequence of the partial trapping of particles by structures in the magnetic field. As a result, the spectrum of accelerated particles is a power-law in momentum which is steeper than in the diffusive case. For a phase-space density f{prop.to}p^-s^, we find s=s_diff_[1+1/(2ρ_c_)], where ρ_c_ is the compression ratio of the shock front and s_diff_ is the standard result of diffusive acceleration: s_diff_=3ρ_c_/(ρ_c_-1). A strong shock in a monatomic ideal gas yields a spectrum of s=4.5. In the case of electrons, this corresponds to a radio synchrotron spectral index of α=0.75.
Impact of compressibility and a guide field on Fermi acceleration during magnetic island coalescence
NASA Astrophysics Data System (ADS)
Montag, Peter; Egedal, Jan; Lichko, Emily; Wetherton, Blake
2017-10-01
Previous work has shown that Fermi acceleration can be an effective heating mechanism during magnetic island coalescence, where electrons may undergo repeated reflections as the magnetic field lines contract. This energization has the potential to account for the power-law distributions of particle energy inferred from observations of solar flares. Here, we develop a generalized framework for the analysis of Fermi acceleration that can incorporate the effects of compressibility and non-uniformity along field lines, which have commonly been neglected in previous treatments of the problem. Applying this framework to the simplified case of the uniform flux tube allows us to find both the power-law scaling of the distribution function and the rate at which the power-law behavior develops. We find that a guide magnetic field of order unity effectively suppresses the development of power-law distributions. The work was supported by NASA Grant No. NNX14AC68G, NSF GEM Grant No. 1405166, NSF Award 1404166, and NASA Award NNX15AJ73G.
Effect of rod length on the morphology of block copolymer/magnetic nanorod composites.
Lo, Chieh-Tsung; Lin, Wei-Ting
2013-05-02
The organization of magnetic nanorods in microphase-separated diblock copolymers composed of poly(styrene-b-2-vinylpyridine) (PS-PVP) as a function of rod length and rod concentration was investigated using both transmission electron microscopy and small-angle X-ray scattering. Our results reveal that the nanorods were sequestered into the PVP domains, which is attributed to the preferential interaction between pyridine-tethered nanorods and PVP. Meanwhile, the addition of nanorods in PS-PVP caused chain stretching. To minimize the energy penalty, nanorods tended to align parallel to the interface between PS and PVP to increase the conformational entropy. As the length of nanorods increased, the increasing van der Waals interaction and magnetic interaction caused extensive rod aggregation, which suppressed the domain size of PVP and amplified the local compositional fluctuations. This creates conditions to induce disorder in the polymer morphology and nanorods undergo macrophase separation.
NASA Astrophysics Data System (ADS)
Sengupta, Abhronil; Roy, Kaushik
2016-02-01
Synaptic memory is considered to be the main element responsible for learning and cognition in humans. Although traditionally nonvolatile long-term plasticity changes are implemented in nanoelectronic synapses for neuromorphic applications, recent studies in neuroscience reveal that biological synapses undergo metastable volatile strengthening followed by a long-term strengthening provided that the frequency of the input stimulus is sufficiently high. Such "memory strengthening" and "memory decay" functionalities can potentially lead to adaptive neuromorphic architectures. In this paper, we demonstrate the close resemblance of the magnetization dynamics of a magnetic tunnel junction (MTJ) to short-term plasticity and long-term potentiation observed in biological synapses. We illustrate that, in addition to the magnitude and duration of the input stimulus, the frequency of the stimulus plays a critical role in determining long-term potentiation of the MTJ. Such MTJ synaptic memory arrays can be utilized to create compact, ultrafast, and low-power intelligent neural systems.
Xiao, Meixia; Yao, Tingzhen; Ao, Zhimin; Wei, Peng; Wang, Danghui; Song, Haiyang
2015-04-14
Density-functional theory calculations are performed to investigate the effects of surface modifications and nanosheet thickness on the electronic and magnetic properties of gallium nitride (GaN) nanosheets (NSs). Unlike the bare GaN NSs terminating with polar surfaces, the systems with hydrogenated Ga (H-GaN), fluorinated Ga (F-GaN), and chlorinated Ga (Cl-GaN) preserve their initial wurtzite structures and exhibit ferromagnetic states. The abovementioned three different decorations on Ga atoms are energetically more favorable for thicker GaN NSs. Moreover, as the thickness increases, H-GaN and F-GaN NSs undergo semiconductor to metal and half-metal to metal transition, respectively, while Cl-GaN NSs remain completely metallic. The predicted diverse and tunable electronic and magnetic properties highlight the potential of GaN NSs for novel electronic and spintronic nanodevices.
Magnetic structure of the mixed antiferromagnet NdMn0.8Fe0.2O3
NASA Astrophysics Data System (ADS)
Mihalik, Matúš; Mihalik, Marián; Hoser, Andreas; Pajerowski, Daniel M.; Kriegner, Dominik; Legut, Dominik; Lebecki, Kristof M.; Vavra, Martin; Fitta, Magdalena; Meisel, Mark W.
2017-10-01
The magnetic structure of the mixed antiferromagnet NdMn0.8Fe0.2O3 was resolved. Neutron powder diffraction data definitively resolve the Mn sublattice with a magnetic propagation vector k =(000 ) and with the magnetic structure (Ax,Fy,Gz ) for 1.6 K
Functional magnetic resonance imaging in clinical practice: State of the art and science.
Barras, Christen D; Asadi, Hamed; Baldeweg, Torsten; Mancini, Laura; Yousry, Tarek A; Bisdas, Sotirios
2016-11-01
Functional magnetic resonance imaging (fMRI) has become a mainstream neuroimaging modality in the assessment of patients being evaluated for brain tumour and epilepsy surgeries. Thus, it is important for doctors in primary care settings to be well acquainted with the present and potential future applications, as well as limitations, of this modality. The objective of this article is to introduce the theoretical principles and state-of-the-art clinical applications of fMRI in brain tumour and epilepsy surgery, with a focus on the implications for clinical primary care. fMRI enables non-invasive functional mapping of specific cortical tasks (eg motor, language, memory-based, visual), revealing information about functional localisation, anatomical variation in cortical function, and disease effects and adaptations, including the fascinating phenomenon of brain plasticity. fMRI is currently ordered by specialist neurologists and neurosurgeons for the purposes of pre-surgical assessment, and within the context of an experienced multidisciplinary team to prepare, conduct and interpret the scan. With an increasing number of patients undergoing fMRI, general practitioners can expect questions about the current and emerging role of fMRI in clinical care from these patients and their families.
NASA Astrophysics Data System (ADS)
Choi, E. S.; Graf, D.; Tokumoto, T.; Brooks, J. S.; Yamada, Jun-Ichi
2007-03-01
We have investigated transport and magnetization properties of β-(BDA-TTP)2MX4 (M=Fe, Ga and X=Cl, Br) as a function of pressure, temperature and magnetic field. The title material undergoes metal-insulator transitions above 100 K at ambient pressure. The insulating phase is suppressed with pressure and superconductivity eventually appears above Pc= 4.5 kbar (X=Cl) and 13 kbar (X=Br). The general temperature-pressure (TP) phase diagram is similar each other, while higher pressure is required for X=Br compounds to suppress the insulating state and induce the superconductivity. Pressure dependent DC magnetization studies on β-(BDA-TTP)2FeCl4 compound revealed that the AFM ordering persist well above Pc. In spite of similarity of phase diagram between M=Fe and M=Ga compounds, magnetoresistance results show distinct behaviors, which indicates the magnetic interaction with the conduction electrons are still effective. The comparison between X=Cl and X=Br compounds suggests the anion-size effect rather than the existence of localized magnetic moments plays more important role in determining the ground state.
Low-temperature magnetic properties of greigite (Fe3S4)
NASA Astrophysics Data System (ADS)
Chang, Liao; Roberts, Andrew P.; Rowan, Christopher J.; Tang, Yan; Pruner, Petr; Chen, Qianwang; Horng, Chorng-Shern
2009-01-01
We provide comprehensive low-temperature magnetic results for greigite (Fe3S4) across the spectrum from superparamagnetic (SP) to multidomain (MD) behavior. It is well known that greigite has no low-temperature magnetic transitions, but we also document that it has strong domain-state dependence of magnetic properties at low temperatures. Blocking of SP grains and increasing thermal stability with decreasing temperature is apparent in many magnetic measurements. Thermally stable single-domain greigite undergoes little change in magnetic properties below room temperature. For pseudo-single-domain (PSD)/MD greigite, hysteresis properties and first-order reversal curve diagrams exhibit minor changes at low temperatures, while remanence continuously demagnetizes because of progressive domain wall unpinning. The low-temperature demagnetization is grain size dependent for PSD/MD greigite, with coarser grains undergoing larger remanence loss. AC susceptibility measurements indicate consistent blocking temperatures (TB) for all synthetic and natural greigite samples, which are probably associated with surficial oxidation. Low-temperature magnetic analysis provides much more information about magnetic mineralogy and domain state than room temperature measurements and enables discrimination of individual components within mixed magnetic mineral assemblages. Low-temperature rock magnetometry is therefore a useful tool for studying magnetic mineralogy and granulometry of greigite-bearing sediments.
Park, Si-Woon; Butler, Andrew J.; Cavalheiro, Vanessa; Alberts, Jay L.; Wolf, Steven L.
2013-01-01
The authors examined serial changes in optical topography in a stroke patient performing a functional task, as well as clinical and physiologic measures while undergoing constraint-induced therapy (CIT). A 73-year-old right hemiparetic patient, who had a subcortical stroke 4 months previously, received 2 weeks of CIT. During the therapy, daily optical topography imaging using near-infrared light was measured serially while the participant performed a functional key-turning task. Clinical outcome measures included the Wolf Motor Function Test (WMFT), Motor Activity Log (MAL), and functional key grip test. Transcranial magnetic stimulation (TMS) and functional magnetic resonance imaging (fMRI) were also used to map cortical areas and hemodynamic brain responses, respectively. Optical topography measurement showed an overall decrease in oxy-hemoglobin concentration in both hemispheres as therapy progressed and the laterality index increased toward the contralateral hemisphere. An increased TMS motor map area was observed in the contralateral cortex following treatment. Posttreatment fMRI showed bilateral primary motor cortex activation, although slightly greater in the contralateral hemisphere, during affected hand movement. Clinical scores revealed marked improvement in functional activities. In one patient who suffered a stroke, 2 weeks of CIT led to improved function and cortical reorganization in the hemisphere contralateral to the affected hand. PMID:15228805
Auriat, Angela M.; Neva, Jason L.; Peters, Sue; Ferris, Jennifer K.; Boyd, Lara A.
2015-01-01
Following stroke, the brain undergoes various stages of recovery where the central nervous system can reorganize neural circuitry (neuroplasticity) both spontaneously and with the aid of behavioral rehabilitation and non-invasive brain stimulation. Multiple neuroimaging techniques can characterize common structural and functional stroke-related deficits, and importantly, help predict recovery of function. Diffusion tensor imaging (DTI) typically reveals increased overall diffusivity throughout the brain following stroke, and is capable of indexing the extent of white matter damage. Magnetic resonance spectroscopy (MRS) provides an index of metabolic changes in surviving neural tissue after stroke, serving as a marker of brain function. The neural correlates of altered brain activity after stroke have been demonstrated by abnormal activation of sensorimotor cortices during task performance, and at rest, using functional magnetic resonance imaging (fMRI). Electroencephalography (EEG) has been used to characterize motor dysfunction in terms of increased cortical amplitude in the sensorimotor regions when performing upper limb movement, indicating abnormally increased cognitive effort and planning in individuals with stroke. Transcranial magnetic stimulation (TMS) work reveals changes in ipsilesional and contralesional cortical excitability in the sensorimotor cortices. The severity of motor deficits indexed using TMS has been linked to the magnitude of activity imbalance between the sensorimotor cortices. In this paper, we will provide a narrative review of data from studies utilizing DTI, MRS, fMRI, EEG, and brain stimulation techniques focusing on TMS and its combination with uni- and multimodal neuroimaging methods to assess recovery after stroke. Approaches that delineate the best measures with which to predict or positively alter outcomes will be highlighted. PMID:26579069
Magnetic spectroscopy and microscopy of functional materials
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jenkins, Catherine Ann
2011-05-01
Heusler intermetallics Mn 2Y Ga and X 2MnGa (X; Y =Fe, Co, Ni) undergo tetragonal magnetostructural transitions that can result in half metallicity, magnetic shape memory, or the magnetocaloric effect. Understanding the magnetism and magnetic behavior in functional materials is often the most direct route to being able to optimize current materials for todays applications and to design novel ones for tomorrow. Synchrotron soft x-ray magnetic spectromicroscopy techniques are well suited to explore the the competing effects from the magnetization and the lattice parameters in these materials as they provide detailed element-, valence-, and site-specifc information on the coupling ofmore » crystallographic ordering and electronic structure as well as external parameters like temperature and pressure on the bonding and exchange. Fundamental work preparing the model systems of spintronic, multiferroic, and energy-related compositions is presented for context. The methodology of synchrotron spectroscopy is presented and applied to not only magnetic characterization but also of developing a systematic screening method for future examples of materials exhibiting any of the above effects. The chapter progression is as follows: an introduction to the concepts and materials under consideration (Chapter 1); an overview of sample preparation techniques and results, and the kinds of characterization methods employed (Chapter 2); spectro- and microscopic explorations of X 2MnGa/Ge (Chapter 3); spectroscopic investigations of the composition series Mn 2Y Ga to the logical Mn 3Ga endpoint (Chapter 4); and a summary and overview of upcoming work (Chapter 5). Appendices include the results of a Think Tank for the Graduate School of Excellence MAINZ (Appendix A) and details of an imaging project now in progress on magnetic reversal and domain wall observation in the classical Heusler material Co 2FeSi (Appendix B).« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schneeweiss, Oldřich; Friák, Martin; Dudová, Marie
In this paper, we present experimental data showing that the equiatomic CrMnFeCoNi high-entropy alloy undergoes two magnetic transformations at temperatures below 100 K while maintaining its fcc structure down to 3 K. The first transition, paramagnetic to spin glass, was detected at 93 K and the second transition of the ferromagnetic type occurred at 38 K. Field-assisted cooling below 38 K resulted in a systematic vertical shift of the hysteresis curves. Strength and direction of the associated magnetization bias was proportional to the strength and direction of the cooling field and shows a linear dependence with a slope of 0.006more » ± 0.001 emu T. The local magnetic moments of individual atoms in the CrMnFeCoNi quinary fcc random solid solution were investigated by ab initio (electronic density functional theory) calculations. Results of the numerical analysis suggest that, irrespective of the initial configuration of local magnetic moments, the magnetic moments associated with Cr atoms align antiferromagnetically with respect to a cumulative magnetic moment of their first coordination shell. The ab initio calculations further showed that the magnetic moments of Fe and Mn atoms remain strong (between 1.5 and 2 μ B), while the local moments of Ni atoms effectively vanish. Finally, these results indicate that interactions of Mn- and/or Fe-located moments with the surrounding magnetic structure account for the observed macroscopic magnetization bias.« less
The interactive effect of social pain and executive functioning on aggression: an fMRI experiment.
Chester, David S; Eisenberger, Naomi I; Pond, Richard S; Richman, Stephanie B; Bushman, Brad J; Dewall, C Nathan
2014-05-01
Social rejection often increases aggression, but the neural mechanisms underlying this effect remain unclear. This experiment tested whether neural activity in the dorsal anterior cingulate cortex (dACC) and anterior insula in response to social rejection predicted greater subsequent aggression. Additionally, it tested whether executive functioning moderated this relationship. Participants completed a behavioral measure of executive functioning, experienced social rejection while undergoing functional magnetic resonance imaging and then completed a task in which they could aggress against a person who rejected them using noise blasts . We found that dACC activation and executive functioning interacted to predict aggression. Specifically, participants with low executive functioning showed a positive association between dACC activation and aggression, whereas individuals with high executive functioning showed a negative association. Similar results were found for the left anterior insula. These findings suggest that social pain can increase or decrease aggression, depending on an individual's regulatory capability.
Effect of magnetic bead agglomeration on Cytomagnetometric measurements.
Möller, Winfried; Nemoto, Iku; Heyder, Joachim
2003-12-01
Magnetic twisting cytometry (MTC) is a novel tool to measure cytoskeleton-associated cell functions by the use of ferromagnetic microbeads. Magnetic beads are either incorporated by living cells by phagocytic processes or attached to integrin receptors to the cell membrane. The magnetic beads are magnetized and aligned in a strong magnetic field pulse. The application of twisting forces allows to investigate mechanical properties (stiffness, viscoelasticity) of the cytoskeleton of living cells by analyzing the magnetic cell field. Incorporated magnetic beads undergo intracellular transport processes, which result in a loss of particle alignment and in a decay of the remanent magnetic cell field. This process, called relaxation, depends on the mechanical cytoskeletal properties and can directly visualize the intracellular energy of cellular transport processes. The preparation of spherical monodisperse ferromagnetic beads made it possible to understand the above-described processes using mathematical models. Experimental conditions with many magnetic particles per cell enhances the formation of aggregates because of the attractive forces between magnetic spheres, resulting in a change of magnetic properties and of hydrodynamic behavior. Due to mutual magnetization, the remanent magnetic moment of an aggregate is stronger compared to the same number of single particles. This implies a higher cell field. Additionally the relaxation is retarded because of the change in shape factor and in volume, which also implies a faulty estimation of intracellular transport energy. Magnetic particle twisting is less influenced. In summary, valuable cytomagnetometric measurements have to be done with less than one particle per macrophage to ensure low probability of multiple particles per cell.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Balescu, R.; Wang, H.; Misguich, J.H.
1994-12-01
The running diffusion coefficient [ital D]([ital t]) is evaluated for a system of charged particles undergoing the effect of a fluctuating magnetic field and of their mutual collisions. The latter coefficient can be expressed either in terms of the mean square displacement (MSD) of a test particle, or in terms of a correlation between a fluctuating distribution function and the magnetic field fluctuation. In the first case a stochastic differential equation of Langevin type for the position of a test particle must be solved; the second problem requires the determination of the distribution function from a kinetic equation. Using suitablemore » simplifications, both problems are amenable to exact analytic solution. The conclusion is that the equivalence of the two approaches is by no means automatically guaranteed. A new type of object, the hybrid kinetic equation'' is constructed: it automatically ensures the equivalence with the Langevin results. The same conclusion holds for the generalized Fokker--Planck equation. The (Bhatnagar--Gross--Krook) (BGK) model for the collisions yields a completely wrong result. A linear approximation to the hybrid kinetic equation yields an inexact behavior, but represents an acceptable approximation in the strongly collisional limit.« less
Current-induced switching in CoGa/L10 MnGa/(CoGa)/Pt structure with different thicknesses
NASA Astrophysics Data System (ADS)
Ranjbar, R.; Suzuki, K. Z.; Mizukami, S.
2018-06-01
In this paper, we present the results of our study into current-induced spin-orbit torque (SOT) switching in perpendicularly magnetized CoGa/MnGa/Pt trilayers with different thicknesses of MnGa and Pt. The SOT switching was observed for all films that undergo Joule heating. We also investigate SOT switching in the bottom (CoGa)/MnGa/top(CoGa/Pt) films with different top layers. Although both the bottom and top layers contribute to the SOT, the relative magnitudes of the switching current densities JC in the top and bottom layers indicate that the SOT is dominant in the top layer. The JC as a function of thickness is discussed in terms of the magnetic properties and resistivity. Experimental data suggested that the MnGa thickness dependence of JC may originate from the perpendicular magnetic anisotropy thickness product Kueff t value. On the other hand, JC as a function of the Pt thickness shows weak dependence. This may be attributed to the slight change of spin-Hall angle θSH value with different thicknesses of Pt, when we assumed that the SOT switching is primarily due to the spin-Hall effect.
Effects of convection electric field on upwelling and escape of ionospheric O(+)
NASA Technical Reports Server (NTRS)
Cladis, J. B.; Chiu, Yam T.; Peterson, William K.
1992-01-01
A Monte Carlo code is used to explore the full effects of the convection electric field on distributions of upflowing O(+) ions from the cusp/cleft ionosphere. Trajectories of individual ions/neutrals are computed as they undergo multiple charge-exchange collisions. In the ion state, the trajectories are computed in realistic models of the magnetic field and the convection, corotation, and ambipolar electric fields. The effects of ion-ion collisions are included, and the trajectories are computed with and without simultaneous stochastic heating perpendicular to the magnetic field by a realistic model of broadband, low frequency waves. In the neutral state, ballistic trajectories in the gravitational field are computed. The initial conditions of the ions, in addition to ambipolar electric field and the number densities and temperatures of O(+), H(+), and electrons as a function of height in the cusp/cleft region were obtained from the results of Gombosi and Killeen (1987), who used a hydrodynamic code to simulate the time-dependent frictional-heating effects in a magnetic tube during its motion though the convection throat. The distribution of the ion fluxes as a function of height are constructed from the case histories.
Statistical mechanics of the cluster Ising model
NASA Astrophysics Data System (ADS)
Smacchia, Pietro; Amico, Luigi; Facchi, Paolo; Fazio, Rosario; Florio, Giuseppe; Pascazio, Saverio; Vedral, Vlatko
2011-08-01
We study a Hamiltonian system describing a three-spin-1/2 clusterlike interaction competing with an Ising-like antiferromagnetic interaction. We compute free energy, spin-correlation functions, and entanglement both in the ground and in thermal states. The model undergoes a quantum phase transition between an Ising phase with a nonvanishing magnetization and a cluster phase characterized by a string order. Any two-spin entanglement is found to vanish in both quantum phases because of a nontrivial correlation pattern. Nevertheless, the residual multipartite entanglement is maximal in the cluster phase and dependent on the magnetization in the Ising phase. We study the block entropy at the critical point and calculate the central charge of the system, showing that the criticality of the system is beyond the Ising universality class.
Anomalous magnetotransport behavior in Fe-doped MnNiGe alloys
NASA Astrophysics Data System (ADS)
Dutta, P.; Pramanick, S.; Singh, Vijay; Major, Dan Thomas; Das, D.; Chatterjee, S.
2016-04-01
The electrical dc transport properties of hexagonal magnetic equiatomic alloys of nominal composition Mn1 -xFexNiGe (x =0.2 and0.25 ) have been investigated experimentally as well as theoretically using first-principles electronic structure calculations. Thermal hysteresis in the magnetization data indicates that the alloys undergo a first-order martensitic transition. Both the alloys show unusual nonmetallic resistivity behavior and a noticeable amount of training effect in resistivity when thermally cycled through the first-order martensitic transition. We observe moderate negative magnetoresistance (˜-11.5 % for 150 kOe) at 5 K (well below the martensitic transition temperature) associated with clear virgin line effect for both the alloys. We have adapted different flavors of density functional theory approach to understand the experimentally observed nonmetallic transport behavior.
Pastor, Nina; Amero, Carlos
2015-01-01
Proteins participate in information pathways in cells, both as links in the chain of signals, and as the ultimate effectors. Upon ligand binding, proteins undergo conformation and motion changes, which can be sensed by the following link in the chain of information. Nuclear magnetic resonance (NMR) spectroscopy and molecular dynamics (MD) simulations represent powerful tools for examining the time-dependent function of biological molecules. The recent advances in NMR and the availability of faster computers have opened the door to more detailed analyses of structure, dynamics, and interactions. Here we briefly describe the recent applications that allow NMR spectroscopy and MD simulations to offer unique insight into the basic motions that underlie information transfer within and between cells. PMID:25999971
Zhang, Myron; Avitsian, Rafi; Bhattacharyya, Pallab; Bulacio, Juan; Cendes, Fernando; Enatsu, Rei; Lowe, Mark; Najm, Imad; Nair, Dileep; Phillips, Michael; Gonzalez-Martinez, Jorge
2014-01-01
Abstract Patients with medically intractable epilepsy often undergo invasive evaluation and surgery, with a 50% success rate. The low success rate is likely due to poor identification of the epileptogenic zone (EZ), the brain area causing seizures. This work introduces a new method using functional magnetic resonance imaging (fMRI) with simultaneous direct electrical stimulation of the brain that could help localize the EZ, performed in five patients with medically intractable epilepsy undergoing invasive evaluation with intracranial depth electrodes. Stimulation occurred in a location near the hypothesized EZ and a location away. Electrical recordings in response to stimulation were recorded and compared to fMRI. Multiple stimulation parameters were varied, like current and frequency. The brain areas showing fMRI response were compared with the areas resected and the success of surgery. Robust fMRI maps of activation networks were easily produced, which also showed a significant but weak positive correlation between quantitative measures of blood-oxygen-level-dependent (BOLD) activity and measures of electrical activity in response to direct electrical stimulation (mean correlation coefficient of 0.38 for all acquisitions that produced a strong BOLD response). For four patients with outcome data at 6 months, successful surgical outcome is consistent with the resection of brain areas containing high local fMRI activity. In conclusion, this method demonstrates the feasibility of simultaneous direct electrical stimulation and fMRI in humans, which allows the study of brain connectivity with high resolution and full spatial coverage. This innovative technique could be used to better define the localization and extension of the EZ in intractable epilepsies, as well as for other functional neurosurgical procedures. PMID:24735069
NASA Astrophysics Data System (ADS)
Sharma, Mohit K.; Yadav, Kavita; Mukherjee, K.
2018-05-01
The binary intermetallic compound Er5Pd2 has been investigated using dc and ac magnetic susceptibilities, magnetic memory effect, isothermal magnetization, non-linear dc susceptibility, heat capacity and magnetocaloric effect studies. Interestingly, even though the compound does not show geometrical frustration it undergoes glassy magnetic phase transition below 17.2 K. Investigation of dc magnetization and heat capacity data divulged absence of long-ranged magnetic ordering. Through the magnetic memory effect, time dependent magnetization and ac susceptibility studies it was revealed that the compound undergoes glass-like freezing below 17.2 K. Analysis of frequency dependence of this transition temperature through scaling and Arrhenius law; along with the Mydosh parameter indicate, that the dynamics in Er5Pd2 are due to the presence of strongly interacting superspins rather than individual spins. This phase transition was further investigated by non-linear dc susceptibility and was characterized by static critical exponents γ and δ. Our results indicate that this compound shows the signature of superspin glass at low temperature. Additionally, both conventional and inverse magnetocaloric effect was observed with a large value of magnetic entropy change and relative cooling power. Our results suggest that Er5Pd2 can be classified as a superspin glass system with large magnetocaloric effect.
Berry, Colin; Zimmerli, Lukas U; Steedman, Tracey; Foster, John E; Dargie, Henry J; Berg, Geoffrey A; Dominiczak, Anna F; Delles, Christian
2008-03-01
Morbidity following CABG (coronary artery bypass grafting) is difficult to predict and leads to increased healthcare costs. We hypothesized that pre-operative CMR (cardiac magnetic resonance) findings would predict resource utilization in elective CABG. Over a 12-month period, patients requiring elective CABG were invited to undergo CMR 1 day prior to CABG. Gadolinium-enhanced CMR was performed using a trueFISP inversion recovery sequence on a 1.5 tesla scanner (Sonata; Siemens). Clinical data were collected prospectively. Admission costs were quantified based on standardized actual cost/day. Admission cost greater than the median was defined as 'increased'. Of 458 elective CABG cases, 45 (10%) underwent pre-operative CMR. Pre-operative characteristics [mean (S.D.) age, 64 (9) years, mortality (1%) and median (interquartile range) admission duration, 7 (6-8) days] were similar in patients who did or did not undergo CMR. In the patients undergoing CMR, eight (18%) and 11 (24%) patients had reduced LV (left ventricular) systolic function by CMR [LVEF (LV ejection fraction) <55%] and echocardiography respectively. LE (late enhancement) with gadolinium was detected in 17 (38%) patients. The average cost/day was $2723. The median (interquartile range) admission cost was $19059 ($10891-157917). CMR LVEF {OR (odds ratio), 0.93 [95% CI (confidence interval), 0.87-0.99]; P=0.03} and SV (stroke volume) index [OR 1.07 (95% CI, 1.00-1.14); P=0.02] predicted increased admission cost. CMR LVEF (P=0.08) and EuroScore tended to predict actual admission cost (P=0.09), but SV by CMR (P=0.16) and LV function by echocardiography (P=0.95) did not. In conclusion, in this exploratory investigation, pre-operative CMR findings predicted admission duration and increased admission cost in elective CABG surgery. The cost-effectiveness of CMR in risk stratification in elective CABG surgery merits prospective assessment.
Enamullah, .; Johnson, D. D.; Suresh, K. G.; ...
2016-11-07
Heusler compounds offer potential as spintronic devices due to their spin polarization and half-metallicity properties, where electron spin-majority (minority) manifold exhibits states (band gap) at the electronic chemical potential, yielding full spin polarization in a single manifold. Yet, Heuslers often exhibit intrinsic disorder that degrades its half-metallicity and spin polarization. Using density-functional theory, we analyze the electronic and magnetic properties of equiatomic Heusler (L2 1) CoMnCrAl and CoFeCrGe alloys for effects of hydrostatic pressure and intrinsic disorder (thermal antisites, binary swaps, and vacancies). Under pressure, CoMnCrAl undergoes a metallic transition, while half-metallicity in CoFeCrGe is retained for a limited range.more » Antisite disorder between Cr-Al pair in CoMnCrAl alloy is energetically the most favorable, and retains half-metallic character in Cr-excess regime. However, Co-deficient samples in both alloys undergo a transition from half-metallic to metallic, with a discontinuity in the saturation magnetization. For binary swaps, configurations that compete with the ground state are identified and show no loss of half-metallicity; however, the minority-spin band gap and magnetic moments vary depending on the atoms swapped. For single binary swaps, there is a significant energy cost in CoMnCrAl but with no loss of half-metallicity. Although a few configurations in CoFeCrGe energetically compete with the ground state, the minority-spin band gap and magnetic moments vary depending on the atoms swapped. Furthermore, this information should help in controlling these potential spintronic materials.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Enamullah, .; Johnson, D. D.; Suresh, K. G.
Heusler compounds offer potential as spintronic devices due to their spin polarization and half-metallicity properties, where electron spin-majority (minority) manifold exhibits states (band gap) at the electronic chemical potential, yielding full spin polarization in a single manifold. Yet, Heuslers often exhibit intrinsic disorder that degrades its half-metallicity and spin polarization. Using density-functional theory, we analyze the electronic and magnetic properties of equiatomic Heusler (L2 1) CoMnCrAl and CoFeCrGe alloys for effects of hydrostatic pressure and intrinsic disorder (thermal antisites, binary swaps, and vacancies). Under pressure, CoMnCrAl undergoes a metallic transition, while half-metallicity in CoFeCrGe is retained for a limited range.more » Antisite disorder between Cr-Al pair in CoMnCrAl alloy is energetically the most favorable, and retains half-metallic character in Cr-excess regime. However, Co-deficient samples in both alloys undergo a transition from half-metallic to metallic, with a discontinuity in the saturation magnetization. For binary swaps, configurations that compete with the ground state are identified and show no loss of half-metallicity; however, the minority-spin band gap and magnetic moments vary depending on the atoms swapped. For single binary swaps, there is a significant energy cost in CoMnCrAl but with no loss of half-metallicity. Although a few configurations in CoFeCrGe energetically compete with the ground state, the minority-spin band gap and magnetic moments vary depending on the atoms swapped. Furthermore, this information should help in controlling these potential spintronic materials.« less
Properties of quasi-periodic oscillations in accreting magnetic white dwarfs
NASA Technical Reports Server (NTRS)
Wu, Kinwah; Chanmugam, G.; Shaviv, G.
1992-01-01
Previous studies of time-dependent accretion onto magnetic white dwarfs, in which the cooling was assumed to be due to bremsstrahlung emission, have shown that the accretion shock undergoes oscillations. However, when cyclotron cooling is also included, the oscillations are damped for sufficiently strong magnetic fields. Here we demonstrate that the oscillations can be sustained by accretion-fluctuation-induced excitations. The frequency of the QPOs are shown to increase quadratically with the magnetic field strength. We interpret the oscillations as a two-phase process in which bremsstrahlung cooling dominates in one half-cycle and cyclotron cooling in the other. Such a process may have very different consequences compared to a single-phase process where the functional form of the cooling is essentially the same throughout the cycle. If in the two-phase process damping occurs mainly in the cyclotron cooling half-cycle, there will be a universal effective damping factor which tends to suppress all oscillation modes indiscriminately. The oscillations of the accretion shock also could be a limit cycle process in which the system vacillates between two branches.
NASA Astrophysics Data System (ADS)
Dhar, Namrata; Jana, Debnarayan
2018-04-01
Ab initio magnetic and optical properties of group IV elements (carbon (C) and silicon (Si)) decorated free standing (FS) buckled germanene systems have been employed theoretically. Our study elucidates that, decoration of these elements in proper sites with suitable concentrations form dynamically stable configurations. Band structure is modified due to decoration of these atoms in Ge-nanosheet and pristine semi-metallic germanene undergoes to semiconductors with a finite amount of bandgap. Interestingly, this bandgap value meets closely the requirement of gap for field effect transistor (FET) applications. Moreover, significant magnetic moment is induced in non-magnetic germanene for C decorated structure and ground state in anti-ferromagnetic in nature for this structure. Along with magnetic property, optical properties like dielectric functions, optical absorption, electron energy loss spectra (EELS), refractive index and reflectivity of these systems have also been investigated. Maximum number of plasma frequencies appear for Si decorated configuration considering both parallel and perpendicular polarizations. In addition, birefringence characteristics of these configurations have also been studied as it is an important parameter in various applications of optical devices, liquid crystal displays, light modulators etc.
Anomalous interfacial tension temperature dependence of condensed phase drops in magnetic fluids
NASA Astrophysics Data System (ADS)
Ivanov, Aleksey S.
2018-05-01
Interfacial tension temperature dependence σ(T) of the condensed phase (drop-like aggregates) in magnetic fluids undergoing field induced phase transition of the "gas-liquid" type was studied experimentally. Numerical analysis of the experimental data has revealed the anomalous (if compared to ordinary one-component fluids) behavior of the σ(T) function for all tested magnetic colloid samples: the condensed phase drops at high T ≈ 75 C exhibit higher σ(T) than the drops condensed at low T ≈ 20 C. The σ(T) behavior is explained by the polydispersity of magnetic colloids: at high T, only the largest colloidal particles are able to take part in the field induced condensation; thus, the increase of T causes the growth of the average particle diameters inside the drop-like aggregates, what in its turn results in the growth of σ(T). The result is confirmed by qualitative theoretical estimations and qualitative experimental observation of the condensed phase "evaporation" process after the applied magnetic field is removed: the drops that are formed due to capillary instability of the drop-like aggregates retract by one order of magnitude faster at high T, and the evaporation of the drops slows down at high T.
Magnetic structure of the mixed antiferromagnet NdMn 0.8 Fe 0.2 O 3
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mihalik, Matus; Mihalik, Marian; Hoser, Andreas
The magnetic structure of the mixed antiferromagnet NdMn 0.8Fe 0.2O 3 was resolved. Neutron powder diffraction data definitively resolve the Mn sublattice with a magnetic propagation vector k=(000) and with the magnetic structure (A x, F y, G z) for 1.6 K N(≈ 59 K). The Nd sublattice has a (0, f y, 0) contribution in the same temperature interval. The Mn sublattice undergoes a spin-reorientation transition at T 1 ≈ 13 K while the Nd magnetic moment abruptly increases at this temperature. Powder x-ray diffraction shows a strong magnetoelastic effect at T N but no additional structural phase transitionsmore » from 3 to 300 K. Density functional theory calculations confirm the magnetic structure of the undoped NdMnO 3 as part of our analysis. Taken together, these results show that the magnetic structure of the Mn sublattice in NdMn 0.8Fe 0.2O 3 is a combination of the Mn and Fe parent compounds, but the magnetic ordering of the Nd sublattice spans a broader temperature interval than in the case of NdMnO 3 and NdFeO 3. Lastly, this result is a consequence of the fact that the Nd ions do not order independently, but via polarization from the Mn/Fe sublattice.« less
Magnetic structure of the mixed antiferromagnet NdMn 0.8 Fe 0.2 O 3
Mihalik, Matus; Mihalik, Marian; Hoser, Andreas; ...
2017-10-27
The magnetic structure of the mixed antiferromagnet NdMn 0.8Fe 0.2O 3 was resolved. Neutron powder diffraction data definitively resolve the Mn sublattice with a magnetic propagation vector k=(000) and with the magnetic structure (A x, F y, G z) for 1.6 K N(≈ 59 K). The Nd sublattice has a (0, f y, 0) contribution in the same temperature interval. The Mn sublattice undergoes a spin-reorientation transition at T 1 ≈ 13 K while the Nd magnetic moment abruptly increases at this temperature. Powder x-ray diffraction shows a strong magnetoelastic effect at T N but no additional structural phase transitionsmore » from 3 to 300 K. Density functional theory calculations confirm the magnetic structure of the undoped NdMnO 3 as part of our analysis. Taken together, these results show that the magnetic structure of the Mn sublattice in NdMn 0.8Fe 0.2O 3 is a combination of the Mn and Fe parent compounds, but the magnetic ordering of the Nd sublattice spans a broader temperature interval than in the case of NdMnO 3 and NdFeO 3. Lastly, this result is a consequence of the fact that the Nd ions do not order independently, but via polarization from the Mn/Fe sublattice.« less
Magnetic properties of the CrMnFeCoNi high-entropy alloy
Schneeweiss, Oldřich; Friák, Martin; Dudová, Marie; ...
2017-07-28
In this paper, we present experimental data showing that the equiatomic CrMnFeCoNi high-entropy alloy undergoes two magnetic transformations at temperatures below 100 K while maintaining its fcc structure down to 3 K. The first transition, paramagnetic to spin glass, was detected at 93 K and the second transition of the ferromagnetic type occurred at 38 K. Field-assisted cooling below 38 K resulted in a systematic vertical shift of the hysteresis curves. Strength and direction of the associated magnetization bias was proportional to the strength and direction of the cooling field and shows a linear dependence with a slope of 0.006more » ± 0.001 emu T. The local magnetic moments of individual atoms in the CrMnFeCoNi quinary fcc random solid solution were investigated by ab initio (electronic density functional theory) calculations. Results of the numerical analysis suggest that, irrespective of the initial configuration of local magnetic moments, the magnetic moments associated with Cr atoms align antiferromagnetically with respect to a cumulative magnetic moment of their first coordination shell. The ab initio calculations further showed that the magnetic moments of Fe and Mn atoms remain strong (between 1.5 and 2 μ B), while the local moments of Ni atoms effectively vanish. Finally, these results indicate that interactions of Mn- and/or Fe-located moments with the surrounding magnetic structure account for the observed macroscopic magnetization bias.« less
Structural, magnetic and electrical properties of a new double-perovskite LaNaMnMoO6 material.
Borchani, Sameh Megdiche; Koubaa, Wissem Cheikh-Rouhou; Megdiche, Makrem
2017-11-01
Structural, magnetic, magnetocaloric, electrical and magnetoresistance properties of an LaNaMnMoO 6 powder sample have been investigated by X-ray diffraction (XRD), magnetic and electrical measurements. Our sample has been synthesized using the ceramic method. Rietveld refinements of the XRD patterns show that our sample is single phase and it crystallizes in the orthorhombic structure with Pnma space group. Magnetization versus temperature in a magnetic applied field of 0.05 T shows that our sample exhibits a paramagnetic-ferromagnetic transition with decreasing temperature. The Curie temperature T C is found to be 320 K. Arrott plots show that all our double-perovskite oxides exhibit a second-order magnetic phase transition. From the measured magnetization data of an LaNaMnMoO 6 sample as a function of the magnetic applied field, the associated magnetic entropy change |-ΔSM| and the relative cooling power (RCP) have been determined. In the vicinity of T C , |-ΔSM| reached, in a magnetic applied field of 8 T, a maximum value of ∼4 J kg -1 K -1 . Our sample undergoes a large magnetocaloric effect at near-room temperature. Resistivity measurements reveal the presence of an insulating-metal transition at Tρ = 180 K. A magnetoresistance of 30% has been observed at room temperature for 6 T, significantly larger than that reported for the A 2 FeMoO 6 (A = Sr, Ba) double-perovskite system.
Superconducting energy storage magnet
NASA Technical Reports Server (NTRS)
Boom, Roger W. (Inventor); Eyssa, Yehia M. (Inventor); Abdelsalam, Mostafa K. (Inventor); Huang, Xianrui (Inventor)
1993-01-01
A superconducting magnet is formed having composite conductors arrayed in coils having turns which lie on a surface defining substantially a frustum of a cone. The conical angle with respect to the central axis is preferably selected such that the magnetic pressure on the coil at the widest portion of the cone is substantially zero. The magnet structure is adapted for use as an energy storage magnet mounted in an earthen trench or tunnel where the strength the surrounding soil is lower at the top of the trench or tunnel than at the bottom. The composite conductor may be formed having a ripple shape to minimize stresses during charge up and discharge and has a shape for each ripple selected such that the conductor undergoes a minimum amount of bending during the charge and discharge cycle. By minimizing bending, the working of the normal conductor in the composite conductor is minimized, thereby reducing the increase in resistance of the normal conductor that occurs over time as the conductor undergoes bending during numerous charge and discharge cycles.
NASA Astrophysics Data System (ADS)
Aprelev, Pavel; McKinney, Bonni; Walls, Chadwick; Kornev, Konstanin G.
2017-07-01
A novel design of a low-field magnetic stage for optical microscopy of droplets and films within a controlled environment is described. The stage consists of five magnetic coils with a 3D magnetic sensor in a feedback control loop, which allows one to manipulate magnetic nano- and microprobes with microtesla fields. A locally uniform time-dependent field within the focal plane of the microscope objective enables one to rotate the probes in a precisely set manner and observe their motion. The probe tracking protocol was developed to follow the probe rotation in real time and relate it with the viscosity of the host liquid. Using this magnetic stage, a method for measuring mPa s-level viscosity of nanoliter droplets and micron thick films in a 10-20 s timeframe is presented and validated. The viscosity of a rapidly changing liquid can be tracked by using only a few visible probes rotating simultaneously. Vapor pressure and temperature around the sample can be controlled to directly measure viscosity as a function of equilibrium vapor pressure; this addresses a significant challenge in characterization of volatile nanodroplets and thin films. Thin films of surfactant solutions undergoing phase transitions upon solvent evaporation were studied and their rheological properties were related to morphological changes in the material.
Dynamic Connectivity Patterns in Conscious and Unconscious Brain
Ma, Yuncong; Hamilton, Christina
2017-01-01
Abstract Brain functional connectivity undergoes dynamic changes from the awake to unconscious states. However, how the dynamics of functional connectivity patterns are linked to consciousness at the behavioral level remains elusive. In this study, we acquired resting-state functional magnetic resonance imaging data during wakefulness and graded levels of consciousness in rats. Data were analyzed using a dynamic approach combining the sliding window method and k-means clustering. Our results demonstrate that whole-brain networks contained several quasi-stable patterns that dynamically recurred from the awake state into anesthetized states. Remarkably, two brain connectivity states with distinct spatial similarity to the structure of anatomical connectivity were strongly biased toward high and low consciousness levels, respectively. These results provide compelling neuroimaging evidence linking the dynamics of whole-brain functional connectivity patterns and states of consciousness at the behavioral level. PMID:27846731
Ferroelectricity by Bose-Einstein condensation in a quantum magnet.
Kimura, S; Kakihata, K; Sawada, Y; Watanabe, K; Matsumoto, M; Hagiwara, M; Tanaka, H
2016-09-26
The Bose-Einstein condensation is a fascinating phenomenon, which results from quantum statistics for identical particles with an integer spin. Surprising properties, such as superfluidity, vortex quantization or Josephson effect, appear owing to the macroscopic quantum coherence, which spontaneously develops in Bose-Einstein condensates. Realization of Bose-Einstein condensation is not restricted in fluids like liquid helium, a superconducting phase of paired electrons in a metal and laser-cooled dilute alkali atoms. Bosonic quasi-particles like exciton-polariton and magnon in solids-state systems can also undergo Bose-Einstein condensation in certain conditions. Here, we report that the quantum coherence in Bose-Einstein condensate of the magnon quasi particles yields spontaneous electric polarization in the quantum magnet TlCuCl 3 , leading to remarkable magnetoelectric effect. Very soft ferroelectricity is realized as a consequence of the O(2) symmetry breaking by magnon Bose-Einstein condensation. The finding of this ferroelectricity will open a new window to explore multi-functionality of quantum magnets.
NASA Astrophysics Data System (ADS)
Hermann, V.; Altmeyer, M.; Ebad-Allah, J.; Freund, F.; Jesche, A.; Tsirlin, A. A.; Hanfland, M.; Gegenwart, P.; Mazin, I. I.; Khomskii, D. I.; Valentí, R.; Kuntscher, C. A.
2018-02-01
Single-crystal x-ray diffraction studies with synchrotron radiation on the honeycomb iridate α -Li2IrO3 reveal a pressure-induced structural phase transition with symmetry lowering from monoclinic to triclinic at a critical pressure of Pc=3.8 GPa. According to the evolution of the lattice parameters with pressure, the transition mainly affects the a b plane and thereby the Ir hexagon network, leading to the formation of Ir-Ir dimers. These observations are independently predicted and corroborated by our ab initio density functional theory calculations where we find that the appearance of Ir-Ir dimers at finite pressure is a consequence of a subtle interplay between magnetism, correlation, spin-orbit coupling, and covalent bonding. Our results further suggest that at Pc the system undergoes a magnetic collapse. Finally we provide a general picture of competing interactions for the honeycomb lattices A2M O3 with A =Li , Na and M =Ir , Ru.
NASA Astrophysics Data System (ADS)
Tseng, Yi-Chuan; Lee, Yang-Chun; Chang, Sih-Wei; Lin, Tzu-Yao; Ma, Dai-Liang; Lin, Bo-Cheng; Chen, Hsuen-Li
2017-11-01
In this study, we found that the large area of electromagnetic field hot zone induced through magnetic dipole resonance of metal-free structures can greatly enhance Raman scattering signals. The magnetic resonant nanocavities, based on high-refractive-index silicon nanoparticles (SiNPs), were designed to resonate at the wavelength of the excitation laser of the Raman system. The well-dispersed SiNPs that were not closely packed displayed significant magnetic dipole resonance and gave a Raman enhancement per unit volume of 59 347. The hot zones of intense electric field were generated not only within the nonmetallic NPs but also around them, even within the underlying substrate. We observed experimentally that gallium nitride (GaN) and silicon carbide (SiC) surfaces presenting very few SiNPs (coverage: <0.3%) could display significantly enhanced (>50%) Raman signals. In contrast, the Raman signals of the underlying substrates were not enhanced by gold nanoparticles (AuNPs), even though these NPs displayed a localized surface plasmon resonance (LSPR) phenomenon. A comparison of the areas of the electric field hot zones (E 2 > 10) generated by SiNPs undergoing magnetic dipole resonance with the electric field hot spots (E 2 > 10) generated by AuNPs undergoing LSPR revealed that the former was approximately 70 times that of the latter. More noteworthily, the electromagnetic field hot zone generated from the SiNP is able to extend into the surrounding and underlying media. Relative to metallic NPs undergoing LSPR, these nonmetallic NPs displaying magnetic dipole resonance were more effective at enhancing the Raman scattering signals from analytes that were underlying, or even far away from, them. This application of magnetic dipole resonance in metal-free structures appears to have great potential for use in developing next-generation techniques for Raman enhancement.
NASA Astrophysics Data System (ADS)
Glagolevskij, Yu. V.
2015-09-01
A possible variant of the evolution of magnetic protostars "before the Hayashi phase" is discussed. Arguments are given in support of the following major properties of magnetic stars: (1) global magnetic dipole fields with predominant orientation of the magnetic lines of force in the plane of the equator of revolution; (2) slow rotation; (3) complex, two and three dipole structures of the magnetic field in a large part of the stars; (4) partition of stars into magnetic and normal in a proportion of 1:10 occurs during the period when the protostellar clouds undergo gravitational collapse "before the Hayashi phase."
Lindsay, Alistair C; Harron, Katie; Jabbour, Richard J; Kanyal, Ritesh; Snow, Thomas M; Sawhney, Paramvir; Alpendurada, Francisco; Roughton, Michael; Pennell, Dudley J; Duncan, Alison; Di Mario, Carlo; Davies, Simon W; Mohiaddin, Raad H; Moat, Neil E
2016-07-01
Cardiovascular magnetic resonance (CMR) can provide important structural information in patients undergoing transcatheter aortic valve implantation. Although CMR is considered the standard of reference for measuring ventricular volumes and mass, the relationship between CMR findings of right ventricular (RV) function and outcomes after transcatheter aortic valve implantation has not previously been reported. A total of 190 patients underwent 1.5 Tesla CMR before transcatheter aortic valve implantation. Steady-state free precession sequences were used for aortic valve planimetry and to assess ventricular volumes and mass. Semiautomated image analysis was performed by 2 specialist reviewers blinded to patient treatment. Patient follow-up was obtained from the Office of National Statistics mortality database. The median age was 81.0 (interquartile range, 74.9-85.5) years; 50.0% were women. Impaired RV function (RV ejection fraction ≤50%) was present in 45 (23.7%) patients. Patients with RV dysfunction had poorer left ventricular ejection fractions (42% versus 69%), higher indexed left ventricular end-systolic volumes (96 versus 40 mL), and greater indexed left ventricular mass (101 versus 85 g/m(2); P<0.01 for all) than those with normal RV function. Median follow-up was 850 days; 21 of 45 (46.7%) patients with RV dysfunction died, compared with 43 of 145 (29.7%) patients with normal RV function (P=0.035). After adjustment for significant baseline variables, both RV ejection fraction ≤50% (hazard ratio, 2.12; P=0.017) and indexed aortic valve area (hazard ratio, 4.16; P=0.025) were independently associated with survival. RV function, measured on preprocedural CMR, is an independent predictor of mortality after transcatheter aortic valve implantation. CMR assessment of RV function may be important in the risk stratification of patients undergoing transcatheter aortic valve implantation. © 2016 American Heart Association, Inc.
Magnetic relaxation behaviour in Pr{sub 2}NiSi{sub 3}
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pakhira, Santanu, E-mail: santanupakhira20006@gmail.com; Mazumdar, Chandan; Ranganathan, R.
2016-05-06
Time dependent isothemal remanent magnetizatin (IRM) behaviour for polycrystalline compound Pr{sub 2}NiSi{sub 3} have been studied below its characteristic temperature. The compound undergoes slow magnetic relaxation with time. Along with competing interaction, non-magnetic atom disorder plays an important role in formation of non-equilibrium glassy like ground state for this compound.
Investigation of room temperature ferromagnetic nanoparticles of Gd 5Si 4
Hadimani, R. L.; Gupta, S.; Harstad, S. M.; ...
2015-07-06
Gd 5(Si xGe 1-x) 4 compounds undergo first-order phase transitions close to room temperature when x ~ = 0.5, which are accompanied by extreme changes of properties. We report the fabrication of the nanoparticles of one of the parent compounds-Gd 5Si 4-using high-energy ball milling. Crystal structure, microstructure, and magnetic properties have been investigated. Particles agglomerate at long milling times, and the particles that are milled >20 min lose crystallinity and no longer undergo magnetic phase transition close to 340 K, which is present in a bulk material. The samples milled for >20 min exhibit a slightly increased coercivity. Asmore » a result, magnetization at a high temperature of 275K decreases with the increase in the milling time.« less
Ultra-wide detectable concentration range of GMR biosensors using Fe3O4 microspheres
NASA Astrophysics Data System (ADS)
Xu, Jie; Li, Qiang; Zong, Weihua; Zhang, Yongcheng; Li, Shandong
2016-11-01
Exchange-biased GMR sensors were employed for biodetection using a DC in-plane measuring method and a magnetic label of Fe3O4 microspheres. It was revealed that an ultra-wide concentration span covering five orders from 10 ng/mL to 1000 μg/mL was achieved in a home-made biodetection device. The concentration x dependence of output voltage difference |ΔV| between with and without magnetic labels, exhibits nonlinear futures, which undergoes two functions depending on the concentration region. For the low concentration region from 10 ng/mL to 10 μg/mL, a logarithmic relation of |ΔV|=26.3lgx+91.4 fits well, while for the high concentration region, a negative exponential function of |ΔV|=3113(1-e-x/250) describes the |ΔV|~x relation better. For the former, the "coffee ring" effect, formed during the solvent evaporation, was considered as the main reason for the nonlinear relation. While for the latter with high concentration, the overlap among the particles and the enhanced interaction of the magnetic dipole were responsible for the nonlinear |ΔV|~x relationship. Moreover, the calculated detectable concentration limit is agreed well with the experimental data.
Unexpected magnetism, and transport properties in mixed lanthanide compound
NASA Astrophysics Data System (ADS)
Pathak, Arjun; Gschneidner, Karl, Jr.; Pecharsky, Vitalij; Ames Laboratory Team
For intelligent materials design it is desirable to have compounds which have multiple functionalities such as a large magnetoresistance, ferromagnetic and ferrimagnetic states, and field-induced first-order metamagnetic transitions. Here, we discuss one such example where we have combined two lanthanide elements Pr and Er in Pr0.6Er0.4Al2. This compound exhibits multiple functionalities in magnetic fields between 1 and 40 kOe. It undergoes only a trivial ferrimagnetism to paramagnetism transition in a zero magnetic field, but Pr0.6Er0.4Al2 exhibits a large positive magnetoresistance (MR) for H >=40 kOe, a small but non negligible negative MR for H <=30 kOe, and a clear Griffiths-like phase behavior at <1 kOe. The compound also exhibits an asymmetry of hysteresis loop, or exchange bias (EB) effect after field cooling from the paramagnetic state. These phenomena are attributed to the competition between single-ion anisotropies of Pr and Er ions coupled with the opposite nearest-neighbor and next-nearest-neighbor exchange interactions. This work was supported by the US Department of Energy, Office of Basic Energy Science, Division of Material Sciences and Engineering. The research was performed at the Ames Laboratory. The Ames Laboratory is operated by Iowa State University for the US D.
Structural, magnetic and electrical properties of a new double-perovskite LaNaMnMoO6 material
Borchani, Sameh Megdiche; Koubaa, Wissem Cheikh-Rouhou; Megdiche, Makrem
2017-01-01
Structural, magnetic, magnetocaloric, electrical and magnetoresistance properties of an LaNaMnMoO6 powder sample have been investigated by X-ray diffraction (XRD), magnetic and electrical measurements. Our sample has been synthesized using the ceramic method. Rietveld refinements of the XRD patterns show that our sample is single phase and it crystallizes in the orthorhombic structure with Pnma space group. Magnetization versus temperature in a magnetic applied field of 0.05 T shows that our sample exhibits a paramagnetic–ferromagnetic transition with decreasing temperature. The Curie temperature TC is found to be 320 K. Arrott plots show that all our double-perovskite oxides exhibit a second-order magnetic phase transition. From the measured magnetization data of an LaNaMnMoO6 sample as a function of the magnetic applied field, the associated magnetic entropy change |−ΔSM| and the relative cooling power (RCP) have been determined. In the vicinity of TC, |−ΔSM| reached, in a magnetic applied field of 8 T, a maximum value of ∼4 J kg−1 K−1. Our sample undergoes a large magnetocaloric effect at near-room temperature. Resistivity measurements reveal the presence of an insulating-metal transition at Tρ = 180 K. A magnetoresistance of 30% has been observed at room temperature for 6 T, significantly larger than that reported for the A2FeMoO6 (A = Sr, Ba) double-perovskite system. PMID:29291087
The interactive effect of social pain and executive functioning on aggression: an fMRI experiment
Eisenberger, Naomi I.; Pond, Richard S.; Richman, Stephanie B.; Bushman, Brad J.; DeWall, C. Nathan
2014-01-01
Social rejection often increases aggression, but the neural mechanisms underlying this effect remain unclear. This experiment tested whether neural activity in the dorsal anterior cingulate cortex (dACC) and anterior insula in response to social rejection predicted greater subsequent aggression. Additionally, it tested whether executive functioning moderated this relationship. Participants completed a behavioral measure of executive functioning, experienced social rejection while undergoing functional magnetic resonance imaging and then completed a task in which they could aggress against a person who rejected them using noise blasts . We found that dACC activation and executive functioning interacted to predict aggression. Specifically, participants with low executive functioning showed a positive association between dACC activation and aggression, whereas individuals with high executive functioning showed a negative association. Similar results were found for the left anterior insula. These findings suggest that social pain can increase or decrease aggression, depending on an individual’s regulatory capability. PMID:23482622
Electron microscopic, rock magnetic and paleomagnetic studies of mid-ocean ridge basalts
NASA Astrophysics Data System (ADS)
Wang, Daming
Mid-ocean ridge basalt (MORB) is the major source of marine magnetic anomalies which are the result of the earth's magnetic reversals recorded sequentially in progressively older oceanic crust, as embodied in the theory of sea-floor spreading. Titanomagnetite, the primary magnetic minerals in MORB, undergoes gradual low-temperature alteration to titanomaghemite after initial formation, presenting the paradoxical situation that apparently the original magnetic record stays well-preserved while carriers of this record undergo fundamental mineralogical transformations. An integrated electron microscopic, rock magnetic and paleomagnetic study of MORB has been carried out with the aim to understand the effects of low-temperaure alteration on magnetic properties of MORB. A component of this study documents the oxidation state of titanomagnetite in variably altered young (< 1 Ma) basalt. Titanomaghemites in discolored rims are, in a general sense, oxidized to a higher degree than those in the relatively unaltered gray interior. The titanomaghemite within the discolored rims appears to have oxidized relatively quickly. However, the alteration front of the discolored rims does not generally coincide with a pronounced jump in oxidation state, suggesting oxidation state of the Fe-Ti oxides and visible alteration in the discolored rims are not directly correlated. The natural remanent magnetization (NRM) of MORB shows comparatively higher intensity in early Tertiary and Cretaceous samples than in 10--30 Ma old samples. No compositional, petrological, rock-magnetic or paleomagnetic patterns are observed to account for the NRM variation trend. Geomagnetic field intensity is the only effect which can not be directly tested on the same samples, but shows a similar pattern as the measured NRM intensities. It is therefore concluded that the geomagnetic field strength was, on-average, significantly greater during the Cretaceous than during the Oligocene and Miocene. I proposed that the variability of oxidation state within a grain changes as a function of age: rapid oxidation giving rise to pronounced non-uniform oxidation within a grain during the first 10 to 20 m.y., whereupon oxidation of titanomagnetite gradually slows down due to equilibration with surrounding fluids. Meanwhile, oxidation gradients decrease gradually within a grain via diffusion. The change of oxidation state within a grain can greatly affect its internal stress, which in turn influences the magnetic stability. This stability, observed as coercivity or mean-destructive fields during alternating-field demagnetization, shows otherwise unexplained variations. These variations can only be explained by variability of oxidation degree within a given grain.
Wise, Richard J S
2003-01-01
The old neurological model of language, based on the writings of Broca, Wernicke and Lichtheim in the 19th century, is now undergoing major modifications. Observations on the anatomy and physiology of auditory processing in non-human primates are giving strong indicators as to how speech perception is organised in the human brain. In the light of this knowledge, functional activation studies with positron emission tomography (PET) and functional magnetic resonance imaging (fMRI) are achieving a new level of precision in the investigation of language organisation in the human brain, in a manner not possible with observations on patients with aphasic stroke. Although the use of functional imaging to inform methods of improving aphasia rehabilitation remains underdeveloped, there are strong indicators that this methodology will provide the means to research a very imperfectly developed area of therapy.
NASA Technical Reports Server (NTRS)
Fisk, L. A.
2005-01-01
The purpose of this grant was to develop a theoretical understanding of the processes by which open magnetic flux undergoes large-scale transport in the solar corona, and to use this understanding to develop a predictive model for the heliospheric magnetic field, the configuration for which is determined by such motions.
Ultrafast switching of the magnetic ground state in d1 titanates though nonlinear phononic coupling
NASA Astrophysics Data System (ADS)
Gu, Mingqiang; Rondinelli, James M.
LaTiO3 and YTiO3 are isostructure d1 titanates, which exhibit distinct magnetic and orbital properties: The former is a G-type antiferromagnet with a 150 K Neel temperature whereas the latter is a rare ferromagnetic (FM) insulator with a 30 K Curie temperature. With first-principles density functional theory calculations, we identify the local structural origin of the magnetic order difference in these orthorhombic perovskites. By increasing the tilt and rotation angles in LaTiO3, respectively, LaTiO3 is predicted to undergo a magnetic phase transition to an FM state. Similarly, decreasing the tilt and rotation angles in YTiO3 leads to a FM-to-AFM phase transition. The underlying physics is attributed to the change in the superexchange coupling between Ti-sites. Last, we propose a route to switch the magnetism in the titanates by controlling the octahedral distortions through dynamical nonlinear phononic coupling. The proposed experiment requires the use of static strain to position the crystal structure in proximity to the structural transition combined with readily achievable fluencies in an ultrafast optical pump-probe geometry The theory work is supported by the U.S Department of Energy, Office of Science, Office of Basic Energy Sciences, under Contract No. DE-SC0012375.
Mixed valence and metamagnetism in a metal flux grown compound Eu{sub 2}Pt{sub 3}Si{sub 5}
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sarkar, Sumanta; Subbarao, Udumula; Joseph, Boby
A new compound Eu{sub 2}Pt{sub 3}Si{sub 5} with plate shaped morphology has been grown from excess In flux. The compound crystallizes in the orthorhombic U{sub 2}Co{sub 3}Si{sub 5} structure type, Ibam space group and the lattice parameters are a=10.007(2) Å, b=11.666(2) Å and c=6.0011(12) Å. The crystal structure of this compound can be conceived as inter-twinned chains of [Pt{sub 2}Si{sub 2}] and [PtSi{sub 3}] tetrahedra connected along [100] direction to give rise to a complex three dimensional [Pt{sub 3}Si{sub 5}] network. Temperature dependent magnetic susceptibility data suggests that Eu{sub 2}Pt{sub 3}Si{sub 5} undergoes a strong antiferromagnetic ordering (T{sub N}=19 K)more » followed by a weak ferromagnetic transition (T{sub C}=5.5 K). The effective magnetic moment/Eu obtained from susceptibility data is 6.78 μ{sub B} accounts mixed valent Eu with almost 85% divalent Eu, which is supported by X-ray absorption near edge spectroscopy. The compound undergoes a metamagnetic transition under applied magnetic field through a probable spin flop mechanism. - Graphical abstract: Eu{sub 2}Pt{sub 3}Si{sub 5}, a new member in the U{sub 2}Co{sub 3}Si{sub 5} (Ibam) family undergoes metamagnetic transition at high magnetic field and Eu is in mixed valence state. - Highlights: • A new compound Eu{sub 2}Pt{sub 3}Si{sub 5} has been synthesized using indium as an inactive metal flux. • The compound undergoes metamagnetic transition at higher field. • Eu in this compound resides in a mixed valence state.« less
Kabbour, Houria; Janod, Etienne; Corraze, Benoît; Danot, Michel; Lee, Changhoon; Whangbo, Myung-Hwan; Cario, Laurent
2008-07-02
The oxychalcogenides A2F2Fe2OQ2 (A = Sr, Ba; Q = S, Se), which contain Fe2O square planar layers of the anti-CuO2 type, were predicted using a modular assembly of layered secondary building units and subsequently synthesized. The physical properties of these compounds were characterized using magnetic susceptibility, electrical resistivity, specific heat, (57)Fe Mossbauer, and powder neutron diffraction measurements and also by estimating their exchange interactions on the basis of first-principles density functional theory electronic structure calculations. These compounds are magnetic semiconductors that undergo a long-range antiferromagnetic ordering below 83.6-106.2 K, and their magnetic properties are well-described by a two-dimensional Ising model. The dominant antiferromagnetic spin exchange interaction between S = 2 Fe(2+) ions occurs through corner-sharing Fe-O-Fe bridges. Moreover, the calculated spin exchange interactions show that the A2F2Fe2OQ2 (A = Sr, Ba; Q = S, Se) compounds represent a rare example of a frustrated antiferromagnetic checkerboard lattice.
Hooper, E. B.; Sovinec, C. R.
2016-10-06
An instability observed in whole-device, resistive magnetohydrodynamic simulations of the driven phase of coaxial helicity injection in the National Spherical Torus eXperiment is identified as a current-driven resistive mode in an unusual geometry that transiently generates a current sheet. The mode consists of plasma flow velocity and magnetic field eddies in a tube aligned with the magnetic field at the surface of the injected magnetic flux. At low plasma temperatures (~10–20 eV), the mode is benign, but at high temperatures (~100 eV) its amplitude undergoes relaxation oscillations, broadening the layer of injected current and flow at the surface of themore » injected toroidal flux and background plasma. The poloidal-field structure is affected and the magnetic surface closure is generally prevented while the mode undergoes relaxation oscillations during injection. Furthermore, this study describes the mode and uses linearized numerical computations and an analytic slab model to identify the unstable mode.« less
NASA Astrophysics Data System (ADS)
Rahman, Altaf Ur; Rahman, Gul; Kratzer, Peter
2018-05-01
The structural, electronic, and magnetic properties of two-dimensional (2D) GaS are investigated using density functional theory (DFT). After confirming that the pristine 2D GaS is a non-magnetic, indirect band gap semiconductor, we consider N and F as substitutional dopants or adsorbed atoms. Except for N substituting for Ga (NGa), all considered cases are found to possess a magnetic moment. Fluorine, both in its atomic and molecular form, undergoes a highly exothermic reaction with GaS. Its site preference (FS or FGa) as substitutional dopant depends on Ga-rich or S-rich conditions. Both for FGa and F adsorption at the Ga site, a strong F–Ga bond is formed, resulting in broken bonds within the GaS monolayer. As a result, FGa induces p-type conductivity in GaS, whereas FS induces a dispersive, partly occupied impurity band about 0.5 e below the conduction band edge of GaS. Substitutional doping with N at both the S and the Ga site is exothermic when using N atoms, whereas only the more favourable site under the prevailing conditions can be accessed by the less reactive N2 molecules. While NGa induces a deep level occupied by one electron at 0.5 eV above the valence band, non-magnetic NS impurities in sufficiently high concentrations modify the band structure such that a direct transition between N-induced states becomes possible. This effect can be exploited to render monolayer GaS a direct-band gap semiconductor for optoelectronic applications. Moreover, functionalization by N or F adsorption on GaS leads to in-gap states with characteristic transition energies that can be used to tune light absorption and emission. These results suggest that GaS is a good candidate for design and construction of 2D optoelectronic and spintronics devices.
Ur Rahman, Altaf; Rahman, Gul; Kratzer, Peter
2018-05-16
The structural, electronic, and magnetic properties of two-dimensional (2D) GaS are investigated using density functional theory (DFT). After confirming that the pristine 2D GaS is a non-magnetic, indirect band gap semiconductor, we consider N and F as substitutional dopants or adsorbed atoms. Except for N substituting for Ga (N Ga ), all considered cases are found to possess a magnetic moment. Fluorine, both in its atomic and molecular form, undergoes a highly exothermic reaction with GaS. Its site preference (F S or F Ga ) as substitutional dopant depends on Ga-rich or S-rich conditions. Both for F Ga and F adsorption at the Ga site, a strong F-Ga bond is formed, resulting in broken bonds within the GaS monolayer. As a result, F Ga induces p-type conductivity in GaS, whereas F S induces a dispersive, partly occupied impurity band about 0.5 e below the conduction band edge of GaS. Substitutional doping with N at both the S and the Ga site is exothermic when using N atoms, whereas only the more favourable site under the prevailing conditions can be accessed by the less reactive N 2 molecules. While N Ga induces a deep level occupied by one electron at 0.5 eV above the valence band, non-magnetic N S impurities in sufficiently high concentrations modify the band structure such that a direct transition between N-induced states becomes possible. This effect can be exploited to render monolayer GaS a direct-band gap semiconductor for optoelectronic applications. Moreover, functionalization by N or F adsorption on GaS leads to in-gap states with characteristic transition energies that can be used to tune light absorption and emission. These results suggest that GaS is a good candidate for design and construction of 2D optoelectronic and spintronics devices.
Risk on the Horizon, Rig for Dark: Solutions to Mitigate DoD’s Reliance on the Fragile Electric Grid
2013-04-01
occurring event that could disrupt the production and delivery of power is a solar storm. Solar storms can create effects in the earth’s magnetic fields ...solar storms, their potential for disruption is evident. The magnetic fields within the sun undergo a 22-year cycle during which the magnetic poles...sunspots.27 Contained in this CME are low- to medium-charged 25 “The Sun’s Magnetic Field ,” NASA’s
NASA Astrophysics Data System (ADS)
Poh, G.; Slavin, J. A.; Lu, S.; Le, G.; Cassak, P.; Eastwood, J. P.; Ozturk, D. S.; Zou, S.; Nakamura, R.; Baumjohann, W.; Russell, C. T.; Gershman, D. J.; Giles, B. L.; Pollock, C.; Moore, T. E.; Torbert, R. B.; Burch, J. L.
2017-12-01
The formation of flux ropes is thought to be an integral part of the process that may have important consequences for the onset and subsequent rate of reconnection in the tail. Earthward flows, i.e. bursty bulk flows (BBFs), generate dipolarization fronts (DFs) as they interact with the closed magnetic flux in their path. Global hybrid simulations and THEMIS observations have shown that earthward-moving flux ropes can undergo magnetic reconnection with the near-Earth dipole field in the downtail region between the Near Earth Neutral Line and the near-Earth dipole field to create DFs-like signatures. In this study, we analyzed sequential "chains" of earthward-moving, ion-scale flux ropes embedded within DFs observed during MMS first tail season. MMS high-resolution plasma measurements indicate that these earthward flux ropes embedded in DFs have a mean bulk flow velocity and diameter of 250 km/s and 1000 km ( 2‒3 ion inertial length λi), respectively. Magnetic reconnection signatures preceding the flux rope/DF encounter were also observed. As the southward-pointing magnetic field in the leading edge of the flux rope reconnects with the northward-pointing geomagnetic field, the characteristic quadrupolar Hall magnetic field in the ion diffusion region and electron outflow jets in the north-south direction are observed. Our results strongly suggest that the earthward moving flux ropes brake and gradually dissipate due to magnetic reconnection with the near Earth magnetic field. We have also examined the occurrence rate of these dissipating flux ropes/DF events as a function of downtail distances.
A muon spin relaxation study of the metal-organic magnet Ni(TCNQ)2
NASA Astrophysics Data System (ADS)
Berlie, Adam; Terry, Ian; Giblin, Sean; Lancaster, Tom; Szablewski, Marek
2013-05-01
An investigation of the magnetism of the deuterated form of the metal-organic ferromagnet Ni(TCNQ)2 using the muon spin relaxation technique, is reported. Ni(TCNQ-D4)2 was synthesized in a similar manner to the protio-form, and the crystalline product formed was found to have a Curie temperature of TC=20 K. This transition temperature was 18% larger than that of the protio-form synthesized in our laboratory. Muon spin relaxation measurements were performed in Zero Field (ZF) and in Longitudinal Fields (LF) of up to 0.45 T. The ZF data confirmed that the sample undergoes a bulk ferromagnetic transition at a temperature similar to that observed by the bulk magnetization data. However, ZF measurements also showed that another transition occurs below approximately 6 K, which is believed to be a transition to a magnetic glassy state. The LF results indicate that a significant dynamical component to the magnetism is present below TC as LF fields up to 0.45 T cannot completely re-polarise the spins of the implanted muons. Moreover, at 5 mT, the data can be fit using a damped oscillatory function. Taken together, the ZF and LF results suggest the presence of two dominant sites for implanted muons, one of which is strongly coupled to the bulk magnetic transition and the other that is more weakly coupled and has a dynamical magnetic environment below TC. Such a situation may be a consequence of muon spin relaxation probing core and surface magnetic environments of nanoparticles or clusters.
Stinson, L W; Murray, M J; Jones, K A; Assef, S J; Burke, M J; Behrens, T L; Lennon, R L
1994-02-01
A microcomputer-controlled closed-loop infusion system (MCCLIS) has been developed that provides stable intraoperative levels of partial neuromuscular blockade. Complete neuromuscular blockade interferes with intraoperative motor-evoked potential (MEP) monitoring used for patients undergoing surgical procedures that place them at risk for spinal cord ischemia. Nine patients were studied during which the MCCLIS maintained stable levels of partial neuromuscular blockade and allowed transcranial magnetic motor-evoked potential (TcM-MEP) monitoring during thoracoabdominal aortic aneurysmectomy. The use of TcM-MEP for monitoring intraoperative spinal cord function was balanced against surgical considerations for muscle relaxation with 80% to 90% neuromuscular blockade fulfilling each requirement. Intraoperative adjustment of partial neuromuscular blockade to facilitate TcM-MEP monitoring was also possible with the MCCLIS. The MCCLIS should allow for further investigation into the sensitivity, specificity, and predictability of TcM-MEP monitoring for any patient at risk for intraoperative spinal cord ischemia including those undergoing thoracoabdominal aortic aneurysmectomy.
Multiple magnetic transitions in EuNiSi3
NASA Astrophysics Data System (ADS)
Patil, Sujata M.; Paulose, P. L.
2018-04-01
EuNiSi3 undergoes multiple magnetic transitions below 50K. We have studied this system using low field ac susceptibility and 151Eu Mössbauer spectroscopy to understand the nature of multiple magnetic transitions. The estimated hyperfine field (hf) at Eu site at 5K is 45 Tesla which is unusually large compared to the normal observed hf of 33T in most of the Eu intermetallics.
Formation and Eruption Process of a Filament in Active Region NOAA 12241
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Jincheng; Yan, Xiaoli; Qu, ZhongQuan
In order to better understand active-region filaments, we present an intensive study on the formation and eruption of a filament in active region NOAA 12241 during the period from 2014 December 18 to 19. Using observations from the Helioseismic and Magnetic Imager (HMI) vector magnetograms, we investigate the helicity injection rate, Lorentz force, and vertical electric current in the entire region associated with the filament. The helicity injection rate before eruption is found to be larger than that after eruption, while the vertical electric current undergoes an increase at first and then a gradual decrease, similar to what the magneticmore » flux undergoes. Meanwhile, we find that the right part of the filament is formed by magnetic reconnection between two bundles of magnetic field lines while the left part originated from shearing motion. The interaction of the two parts causes the eruption of this filament. The mean horizontal magnetic fields in the vicinity of the magnetic polarity inversion line (PIL) enhance rapidly during the eruption. Another striking phenomenon, where the vertical electric currents close to the magnetic PIL suddenly expand toward two sides during the eruption, is found. We propose that this fascinating feature is associated with the release of energy during the eruption.« less
Schmidt, Ehud J; Watkins, Ronald D; Zviman, Menekhem M; Guttman, Michael A; Wang, Wei; Halperin, Henry A
2016-10-01
Subjects undergoing cardiac arrest within a magnetic resonance imaging (MRI) scanner are currently removed from the bore and then from the MRI suite, before the delivery of cardiopulmonary resuscitation and defibrillation, potentially increasing the risk of mortality. This precludes many higher-risk (acute ischemic and acute stroke) patients from undergoing MRI and MRI-guided intervention. An MRI-conditional cardiac defibrillator should enable scanning with defibrillation pads attached and the generator ON, enabling application of defibrillation within the seconds of MRI after a cardiac event. An MRI-conditional external defibrillator may improve patient acceptance for MRI procedures. A commercial external defibrillator was rendered 1.5 Tesla MRI-conditional by the addition of novel radiofrequency filters between the generator and commercial disposable surface pads. The radiofrequency filters reduced emission into the MRI scanner and prevented cable/surface pad heating during imaging, while preserving all the defibrillator monitoring and delivery functions. Human volunteers were imaged using high specific absorption rate sequences to validate MRI image quality and lack of heating. Swine were electrically fibrillated (n=4) and thereafter defibrillated both outside and inside the MRI bore. MRI image quality was reduced by 0.8 or 1.6 dB, with the generator in monitoring mode and operating on battery or AC power, respectively. Commercial surface pads did not create artifacts deeper than 6 mm below the skin surface. Radiofrequency heating was within US Food and Drug Administration guidelines. Defibrillation was completely successful inside and outside the MRI bore. A prototype MRI-conditional defibrillation system successfully defibrillated in the MRI without degrading the image quality or increasing the time needed for defibrillation. It can increase patient acceptance for MRI procedures. © 2016 American Heart Association, Inc.
Emergence of higher order rotational symmetry in the hidden order phase of URu 2Si 2
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kanchanavatee, N.; Janoschek, M.; Huang, K.
2016-09-30
Electrical resistivity measurements were performed in this paper as functions of temperature, magnetic field, and angle θ between the magnetic field and the c-axis of a URu 2Si 2 single crystal. The resistivity exhibits a two-fold oscillation as a function of θ at high temperatures, which undergoes a 180°-phase shift (sign change) with decreasing temperature at around 35 K. The hidden order transition is manifested as a minimum in the magnetoresistance and amplitude of the two-fold oscillation. Interestingly, the resistivity also showed four-fold, six-fold, and eight-fold symmetries at the hidden order transition. These higher order symmetries were also detected atmore » low temperatures, which could be a sign of the formation of another pseudogap phase above the superconducting transition, consistent with recent evidence for a pseudogap from point-contact spectroscopy measurements and NMR. Measurements of the magnetisation of single crystalline URu 2Si 2 with the magnetic field applied parallel and perpendicular to the crystallographic c-axis revealed regions with linear temperature dependencies between the hidden order transition temperature and about 25 K. Finally, this T-linear behaviour of the magnetisation may be associated with the formation of a precursor phase or ‘pseudogap’ in the density of states in the vicinity of 30–35 K.« less
Hueb, Whady; Gersh, Bernard J; Rezende, Paulo Cury; Garzillo, Cibele Larrosa; Lima, Eduardo Gomes; Vieira, Ricardo D'Oliveira; Garcia, Rosa Maria Rahmi; Favarato, Desiderio; Segre, Carlos Alexandre W; Pereira, Alexandre Costa; Soares, Paulo Rogério; Ribeiro, Expedito; Lemos, Pedro; Perin, Marco A; Strunz, Célia Cassaro; Dallan, Luis A O; Jatene, Fabio B; Stolf, Noedir A G; Hueb, Alexandre Ciappina; Dias, Ricardo; Gaiotto, Fabio A; da Costa, Leandro Menezes Alves; Oikawa, Fernando Teiichi Costa; de Melo, Rodrigo Morel Vieira; Serrano, Carlos Vicente; de Ávila, Luiz Francisco Rodrigues; Villa, Alexandre Volney; Filho, José Rodrigues Parga; Nomura, César; Ramires, José A F; Kalil Filho, Roberto
2012-08-16
Although the release of cardiac biomarkers after percutaneous (PCI) or surgical revascularization (CABG) is common, its prognostic significance is not known. Questions remain about the mechanisms and degree of correlation between the release, the volume of myocardial tissue loss, and the long-term significance. Delayed-enhancement of cardiac magnetic resonance (CMR) consistently quantifies areas of irreversible myocardial injury. To investigate the quantitative relationship between irreversible injury and cardiac biomarkers, we will evaluate the extent of irreversible injury in patients undergoing PCI and CABG and relate it to postprocedural modifications in cardiac biomarkers and long-term prognosis. The study will include 150 patients with multivessel coronary artery disease (CAD) with left ventricle ejection fraction (LVEF) and a formal indication for CABG; 50 patients will undergo CABG with cardiopulmonary bypass (CPB); 50 patients with the same arterial and ventricular condition indicated for myocardial revascularization will undergo CABG without CPB; and another 50 patients with CAD and preserved ventricular function will undergo PCI using stents. All patients will undergo CMR before and after surgery or PCI. We will also evaluate the release of cardiac markers of necrosis immediately before and after each procedure. Primary outcome considered is overall death in a 5-year follow-up. Secondary outcomes are levels of CK-MB isoenzyme and I-Troponin in association with presence of myocardial fibrosis and systolic left ventricle dysfunction assessed by CMR. The MASS-V Trial aims to establish reliable values for parameters of enzyme markers of myocardial necrosis in the absence of manifest myocardial infarction after mechanical interventions. The establishments of these indices have diagnostic value and clinical prognosis and therefore require relevant and different therapeutic measures. In daily practice, the inappropriate use of these necrosis markers has led to misdiagnosis and therefore wrong treatment. The appearance of a more sensitive tool such as CMR provides an unprecedented diagnostic accuracy of myocardial damage when correlated with necrosis enzyme markers. We aim to correlate laboratory data with imaging, thereby establishing more refined data on the presence or absence of irreversible myocardial injury after the procedure, either percutaneous or surgical, and this, with or without the use of cardiopulmonary bypass.
Fierstra, Jorn; Burkhardt, Jan-Karl; van Niftrik, Christiaan Hendrik Bas; Piccirelli, Marco; Pangalu, Athina; Kocian, Roman; Neidert, Marian Christoph; Valavanis, Antonios; Regli, Luca; Bozinov, Oliver
2017-02-01
To assess the feasibility of functional blood oxygen-level dependent (BOLD) MRI to evaluate intraoperative cerebrovascular reactivity (CVR) at 3 Tesla field strength. Ten consecutive neurosurgical subjects scheduled for a clinical intraoperative MRI examination were enrolled in this study. In addition to the clinical protocol a BOLD sequence was implemented with three cycles of 44 s apnea to calculate CVR values on a voxel-by-voxel basis throughout the brain. The CVR range was then color-coded and superimposed on an anatomical volume to create high spatial resolution CVR maps. Ten subjects (mean age 34.8 ± 13.4; 2 females) uneventfully underwent the intraoperative BOLD protocol, with no complications occurring. Whole-brain CVR for all subjects was (mean ± SD) 0.69 ± 0.42, whereas CVR was markedly higher for tumor subjects as compared to vascular subjects, 0.81 ± 0.44 versus 0.33 ± 0.10, respectively. Furthermore, color-coded functional maps could be robustly interpreted for a whole-brain assessment of CVR. We demonstrate that intraoperative BOLD MRI is feasible in creating functional maps to assess cerebrovascular reactivity throughout the brain in subjects undergoing a neurosurgical procedure. Magn Reson Med 77:806-813, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.
Secchi, Francesco; Resta, Elda C; Cannaò, Paola M; Pluchinotta, Francesca; Piazza, Luciane; Butera, Gianfranco; Carminati, Mario; Sardanelli, Francesco
2017-11-01
The aim of this study was to evaluate the impact of percutaneous pulmonary valve implantation (PPVI) and surgical pulmonary valve replacement (SPVR) on biventricular and pulmonary valve function using cardiac magnetic resonance. Thirty-five patients aged 20±8 years (mean±SD) underwent PPVI, whereas 16 patients aged 30±11 years underwent SPVR. Cardiac magnetic resonance examinations were performed before and after the procedures with an average follow-up interval of 10 months. Cine steady-state free precession sequences for cardiac function and phase-contrast sequences for pulmonary flow were performed. The right ventricle (RV) and left ventricle (LV) functions were evaluated using a dedicated software. The RV end-diastolic volume index (mL/m) decreased significantly after PPVI and SPVR, from 74 to 64 (P=0.030) and from 137 to 83 (P=0.001), respectively. The RV ejection fraction increased significantly after SPVR, from 47% to 53% (P=0.038). The LV end-diastolic volume index increased significantly after PPVI, from 66 to 76 mL/m (P<0.001). The LV stroke volume index increased significantly after PPVI, from 34 to 43 mL/m (P=0.004). The analysis of bivariate correlations showed that in patients undergoing SPVR the RV changes after the procedure were positively correlated to LV changes in terms of end-systolic volume index (r=0587; P=0.017) and ejection fraction (r=0.681; P=0.004). A RV volumetric reduction and a positive effect on ventricular-ventricular interaction were observed after both PPVI and SPVR. After PPVI, a positive volumetric LV remodeling was found. No LV remodeling was found after SPVR. After both procedures, the replaced pulmonary valve functioned well.
Objective visual assessment of antiangiogenic treatment for wet age-related macular degeneration.
Baseler, Heidi A; Gouws, André; Crossland, Michael D; Leung, Carmen; Tufail, Adnan; Rubin, Gary S; Morland, Antony B
2011-10-01
To assess cortical responses in patients undergoing antiangiogenic treatment for wet age-related macular degeneration (AMD) using functional magnetic resonance imaging (fMRI) as an objective, fixation-independent measure of topographic visual function. A patient with bilateral neovascular AMD was scanned using fMRI before and at regular intervals while undergoing treatment with intravitreal antiangiogenic injections (ranibizumab). Blood oxygenation level-dependent signals were measured in the brain while the patient viewed a stimulus consisting of a full-field flickering (6 Hz) white light alternating with a uniform gray background (18 s on and 18 s off). Topographic distribution and magnitude of activation in visual cortex were compared longitudinally throughout the treatment period (<1 year) and with control patients not currently undergoing treatment. Clinical behavioral tests were also administered, including visual acuity, microperimetry, and reading skills. The area of visual cortex activated increased significantly after the first treatment to include more posterior cortex that normally receives inputs from lesioned parts of the retina. Subsequent treatments yielded no significant further increase in activation area. Behavioral measures all generally showed an improvement with treatment but did not always parallel one another. The untreated control patient showed a consistent lack of significant response in the cortex representing retinal lesions. Retinal treatments may not only improve vision but also result in a concomitant improvement in fixation stability. Current clinical behavioral measures (e.g., acuity and perimetry) are largely dependent on fixation stability and therefore cannot separate improvements of visual function from fixation improvements. fMRI, which provides an objective and sensitive measure of visual function independent of fixation, reveals a significant increase in visual cortical responses in patients with wet AMD after treatment with antiangiogenic injections. Despite recent evidence that visual cortex degenerates subsequent to retinal lesions, our results indicate that it can remain responsive as its inputs are restored.
Upgrade of the LHC magnet interconnections thermal shielding
NASA Astrophysics Data System (ADS)
Musso, Andrea; Barlow, Graeme; Bastard, Alain; Charrondiere, Maryline; Chrul, Anna; Damianoglou, Dimitrios; Deferne, Guy; Dib, Gaëlle; Duret, Max; Guinchard, Michael; Prin, Hervé; Strychalski, Michał; Craen, Arnaud Vande; Villiger, Gilles; Wright, Loren
2014-01-01
The about 1700 interconnections (ICs) between the Large Hadron Collider (LHC) superconducting magnets include thermal shielding at 50-75 K, providing continuity to the thermal shielding of the magnet cryostats to reduce the overall radiation heat loads to the 1.9 K helium bath of the magnets. The IC shield, made of aluminum, is conduction-cooled via a welded bridge to the thermal shield of the adjacent magnets which is actively cooled. TIG welding of these bridges made in the LHC tunnel at installation of the magnets induced a considerable risk of fire hazard due to the proximity of the multi-layer insulation of the magnet shields. A fire incident occurred in one of the machine sectors during machine installation, but fortunately with limited consequences thanks to prompt intervention of the operators. LHC is now undergoing a 2 years technical stop during which all magnet's ICs will have to be opened to consolidate the magnet electrical connections. The IC thermal shields will therefore have to be removed and re-installed after the work is completed. In order to eliminate the risk of fire hazard when re-welding, it has been decided to review the design of the IC shields, by replacing the welded bridges with a mechanical clamping which also preserves its thermal function. An additional advantage of this new solution is the ease in dismantling for maintenance, and eliminating weld-grinding operations at removal needing radioprotection measures because of material activation after long-term operation of the LHC. This paper describes the new design of the IC shields and in particular the theoretical and experimental validation of its thermal performance. Furthermore a status report of the on-going upgrade work in the LHC is given.
Spectroscopic signatures of localization with interacting photons in superconducting qubits
NASA Astrophysics Data System (ADS)
Roushan, P.; Neill, C.; Tangpanitanon, J.; Bastidas, V. M.; Megrant, A.; Barends, R.; Chen, Y.; Chen, Z.; Chiaro, B.; Dunsworth, A.; Fowler, A.; Foxen, B.; Giustina, M.; Jeffrey, E.; Kelly, J.; Lucero, E.; Mutus, J.; Neeley, M.; Quintana, C.; Sank, D.; Vainsencher, A.; Wenner, J.; White, T.; Neven, H.; Angelakis, D. G.; Martinis, J.
2017-12-01
Quantized eigenenergies and their associated wave functions provide extensive information for predicting the physics of quantum many-body systems. Using a chain of nine superconducting qubits, we implement a technique for resolving the energy levels of interacting photons. We benchmark this method by capturing the main features of the intricate energy spectrum predicted for two-dimensional electrons in a magnetic field—the Hofstadter butterfly. We introduce disorder to study the statistics of the energy levels of the system as it undergoes the transition from a thermalized to a localized phase. Our work introduces a many-body spectroscopy technique to study quantum phases of matter.
GMC COLLISIONS AS TRIGGERS OF STAR FORMATION. I. PARAMETER SPACE EXPLORATION WITH 2D SIMULATIONS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wu, Benjamin; Loo, Sven Van; Tan, Jonathan C.
We utilize magnetohydrodynamic (MHD) simulations to develop a numerical model for giant molecular cloud (GMC)–GMC collisions between nearly magnetically critical clouds. The goal is to determine if, and under what circumstances, cloud collisions can cause pre-existing magnetically subcritical clumps to become supercritical and undergo gravitational collapse. We first develop and implement new photodissociation region based heating and cooling functions that span the atomic to molecular transition, creating a multiphase ISM and allowing modeling of non-equilibrium temperature structures. Then in 2D and with ideal MHD, we explore a wide parameter space of magnetic field strength, magnetic field geometry, collision velocity, andmore » impact parameter and compare isolated versus colliding clouds. We find factors of ∼2–3 increase in mean clump density from typical collisions, with strong dependence on collision velocity and magnetic field strength, but ultimately limited by flux-freezing in 2D geometries. For geometries enabling flow along magnetic field lines, greater degrees of collapse are seen. We discuss observational diagnostics of cloud collisions, focussing on {sup 13}CO(J = 2–1), {sup 13}CO(J = 3–2), and {sup 12}CO(J = 8–7) integrated intensity maps and spectra, which we synthesize from our simulation outputs. We find that the ratio of J = 8–7 to lower-J emission is a powerful diagnostic probe of GMC collisions.« less
Mantle Metasomatism under Island Arcs, Magnetic Implications
NASA Astrophysics Data System (ADS)
Friedman, S. A.; Ferre, E. C.; Arai, S.
2013-12-01
The wedge of upper mantle beneath oceanic and island arcs receives an abundant flux of fluids derived from dehydration of subducted slabs. These fluids may cause metasomatism, serpentinization or partial melting at increasing distance from the trench. Each one of these processes profoundly modifies the oxygen fugacity, mineral assemblage, rheology and seismic properties of mantle rocks. Mantle xenoliths in arcs are relatively rare compared to other tectonic settings yet, due to their rapid ascent, they provide the best record of mantle rocks at depth. Previous studies on the metasomatism of the arc mantle wedge focused on the geochemistry and mineralogy of these xenoliths. Here we present new rock magnetic and paleomagnetic results to track changes in the magnetic assemblage of mantle peridotites. Peridotites undergo a wide range of fluid-reactions that involve formation of magnetically remanent phases such as magnetite, maghemite, hematite or monosulfide solutions. Samples for this study originate from three localities displaying different degrees of metasomatism: a) Five samples from Ichinomegata crater, Megata volcano, in NE Japan are characteristically lherzolitic with metasomatic pargasite present; b) Six samples from Kurose, Hakata Bay, in SW Japan are mainly harzburgites that contain rare, late stage metasomatic sulfides; and c) Ten samples from the Iraya volcano, Batan Island, in the Philippines are lherzolites, harzburgites, and dunites that contain metasomatic olivine, orthopyroxene, clinopyroxene and pargasite. Both remanent and induced magnetizations of these mantle peridotites exhibit systematic variations as a function of the degrees of metasomatism. The contribution of these mantle peridotites to long wavelength magnetic anomalies might be significant.
NASA Astrophysics Data System (ADS)
Thanh, Tran Dang; Dung, Nguyen Thi; Van Dang, Nguyen; Bau, Le Viet; Piao, Hong-Guang; Phan, The Long; Huyen Yen, Pham Duc; Hau, Kieu Xuan; Kim, Dong-Hyun; Yu, Seong-Cho
2018-05-01
In this work, we point out that the width and the nature of the magnetic phase transition, TC value, and as well as magnetocaloric effect in La0.7-xSmxCa0.3MnO3 compounds can be easily modified through Sm-doped into La-site. With an increasing Sm concentration, a systematic decrease in the magnetization, TC, and magnetic entropy change (ΔSm) are observed. The Arrott-plot proveds that the samples with x = 0 and 0.1 undergoing a first-order phase transition. Meanwhile, sample x = 0.2 undergoes a second-order phase transition, which exhibits a high value of the relative cooling power (81.5 J/kg at ΔH = 10 kOe). An analysis of the critical behavior based on the modified Arrott plots method has been done for sample x = 0.2. The results proved a coexistence of the long- and short-range interactions in La0.5Sm0.2Ca0.3MnO3 compound.
Temperature-driven Phase Transformation in Y3Co: Neutron Scattering and DFT Studies
NASA Astrophysics Data System (ADS)
Podlesnyak, A.; Ehlers, G.; Cao, H.; Matsuda, M.; Frontzek, M.; Zaharko, O.; Kazantsev, V. A.; Gubkin, A. F.; Baranov, N. V.
2013-03-01
The effects of a crystal structure deformation due to subtle atomic displacements have attracted much attention because they can result in colossal changes of the electronic and magnetic properties of solids. The R3Co binary intermetallic systems exhibit a number of complicated phenomena, including field-induced magnetic phase transitions (R=Er, Ho, Tb), giant magnetoresistance (R=Dy), a substantial magnetocaloric effect (R=Gd) and superconductivity (R=La). Contrary to previous studies that defined the ground state crystal structure of the entire R3Co series as orthorhombic Pnma, we find that Y3Co undergoes a structural phase transition upon cooling around Tc 160K. Density functional theory calculations reveal a dynamical instability of the Pnma structure of Y3Co. Employing inelastic neutron scattering measurements we find a strong damping of the (00 ξ) acoustic phonon mode below the critical temperature Tc. We suggest that some other members of the R3Co series (or even all of them) have ground state crystal symmetry lower than reported Pnma. This raises a question about the true magnetic structures and hence the influence of magnetic properties of the entire R3Co series. The research at ORNL was sponsored by the Scientific User Facilities Division, Office of Basic Energy Sciences, US Department of Energy.
NASA Astrophysics Data System (ADS)
Thomas, Sarah; Montgomery, Jeffrey; Tsoi, Georgiy; Vohra, Yogesh; Weir, Samuel; Tulk, Christopher; Moreira Dos Santos, Antonio
2013-06-01
Neutron diffraction and electrical transport measurements have been carried out on the heavy rare earth metal terbium at high pressures and low temperatures in order to elucidate its transition from a helical antiferromagnetic to a ferromagnetic ordered phase as a function of pressure. The electrical resistance measurements using designer diamonds show a change in slope as the temperature is lowered through the ferromagnetic Curie temperature. The temperature of the ferromagnetic transition decreases at a rate of -16.7 K/GPa till 3.6 GPa, where terbium undergoes a structural transition from hexagonal close packed (hcp) to an α-Sm phase. Above this pressure, the electrical resistance measurements no longer exhibit a change in slope. In order to confirm the change in magnetic phase suggested by the electrical resistance measurements, neutron diffraction measurements were conducted at the SNAP beamline at the Oak Ridge National Laboratory. Measurements were made at pressures to 5.3 GPa and temperatures as low as 90 K. An abrupt increase in peak intensity in the neutron diffraction spectra signaled the onset of magnetic order below the Curie temperature. A magnetic phase diagram of rare earth metal terbium will be presented to 5.3 GPa and 90 K based on these studies.
NASA Astrophysics Data System (ADS)
Bose, Adity; Dey, Debarati; Basu, Samita
2008-04-01
The magnetic field effect (MFE) in conjunction with laser flash photolysis has been used for the study of the interaction of one of the small drug like quinone molecules, 2-methyl, 1,4-naphthoquinone, commonly known as menadione (MQ), with one of the DNA bases, thymine (THN), and its corresponding nucleoside, thymidine (THDN), in acetonitrile (ACN) and sodium dodecylsulfate (SDS) micelles. It has been observed that THN undergoes electron transfer (ET) and hydrogen (H) abstraction with MQ, while THDN undergoes only H abstraction in both the media. However, our earlier studies showed that a purine base, adenine (ADN), and its nucleoside, 2'-deoxyadenosine (ADS), undergo ET in ACN and H abstraction in SDS. Here we have attempted to explain the differences in the reactions of these DNA bases with MQ. We also reveal the crucial role of a sugar unit in altering the behavior of purine and pyrimidine bases with respect to ET and H abstraction.
Formation of Close-in Super-Earths in an Evolving Disk Due to Disk Winds
NASA Astrophysics Data System (ADS)
Ogihara, Masahiro; Kokubo, Eiichiro; Suzuki, Takeru; Morbidelli, Alessandro
2018-04-01
Planets with masses larger than Mars mass undergo rapid inward migration (type I migration) in a standard protoplanetary disk. Recent magnetohydrodynamical simulations revealed the presence of magnetically-driven disk winds, which would alter the disk profile and the type I migration in the close-in region (r<1 au). We investigate orbital evolution of planetary embryos in a disk that viscously evolves under effects of magnetically-driven disk winds. The aim is to examine whether observed distributions of close-in super-Earths can be reproduced by simulations. We find that the type I migration is significantly suppressed in a disk with flat surface density profile. After planetary embryos undergo slow inward migration, they are captured in a resonant chain. The resonant chain undergoes late orbital instability during the gas depletion, leading to a non-resonant configuration. We also find that observed distributions of close-in super-Earths (e.g., period ratio, mass ratio) can be reproduced by results of simulations.
The effects of magnetic fields and protostellar feedback on low-mass cluster formation
NASA Astrophysics Data System (ADS)
Cunningham, Andrew J.; Krumholz, Mark R.; McKee, Christopher F.; Klein, Richard I.
2018-05-01
We present a large suite of simulations of the formation of low-mass star clusters. Our simulations include an extensive set of physical processes - magnetohydrodynamics, radiative transfer, and protostellar outflows - and span a wide range of virial parameters and magnetic field strengths. Comparing the outcomes of our simulations to observations, we find that simulations remaining close to virial balance throughout their history produce star formation efficiencies and initial mass function (IMF) peaks that are stable in time and in reasonable agreement with observations. Our results indicate that small-scale dissipation effects near the protostellar surface provide a feedback loop for stabilizing the star formation efficiency. This is true regardless of whether the balance is maintained by input of energy from large-scale forcing or by strong magnetic fields that inhibit collapse. In contrast, simulations that leave virial balance and undergo runaway collapse form stars too efficiently and produce an IMF that becomes increasingly top heavy with time. In all cases, we find that the competition between magnetic flux advection towards the protostar and outward advection due to magnetic interchange instabilities, and the competition between turbulent amplification and reconnection close to newly formed protostars renders the local magnetic field structure insensitive to the strength of the large-scale field, ensuring that radiation is always more important than magnetic support in setting the fragmentation scale and thus the IMF peak mass. The statistics of multiple stellar systems are similarly insensitive to variations in the initial conditions and generally agree with observations within the range of statistical uncertainty.
Proton magnetic resonance spectroscopy in adult cancer patients with delirium
Yager, Jeffrey R.; Magnotta, Vincent A.; Mills, James A.; Vik, Stacie M.; Weckmann, Michelle T.; Capizzano, Aristides A.; Gingrich, Roger; Beglinger, Leigh J.
2010-01-01
Background Delirium is associated with a host of negative outcomes, including increased risk of mortality, longer hospital stay, and poor long-term cognitive function. The pathophysiology of delirium is not well understood. Cancer patients undergoing a bone marrow transplant (BMT) are at high risk for developing delirium and Proton Magnetic Resonance Spectroscopy (1H-MRS) could lead to better understanding of the delirium process. Methods Fourteen BMT patients and 10 controls completed 1H-MRS, positioned above the corpus callosum, shortly after delirium onset or at study end if no delirium occurred. Results In the BMT-delirium group, statistically significantly elevated tCho/tCr was found in contrast to the BMT-no delirium group (p<0.05). The BMT–delirium group also showed statistically significantly lesser NAA/tCho compared to both controls (p=0.01) and the BMT–no delirium group (p=0.04). Conclusions Elevated choline and reduced NAA indicate inflammatory processes and white matter damage as well as neuronal metabolic impairment. Further research is needed to separate the choline peaks, as well as more detailed collection of medication regimens to determine whether a higher choline concentration is a function of the delirium process or cancer treatment effects. PMID:21227658
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stancanello, Joseph; Cavedon, Carlo; Francescon, Paolo
Functional magnetic resonance imaging (fMRI) is used to distinguish areas of the brain responsible for different tasks and functions. It is possible, for example, by using fMRI images, to identify particular regions in the brain which can be considered as 'functional organs at risk' (fOARs), i.e., regions which would cause significant patient morbidity if compromised. The aim of this study is to propose and validate a method to exploit functional information for the identification of fOARs in CyberKnife (Accuray, Inc., Sunnyvale, CA) radiosurgery treatment planning; in particular, given the high spatial accuracy offered by the CyberKnife system, local nonrigid registrationmore » is used to reach accurate image matching. Five patients affected by arteriovenous malformations (AVMs) and scheduled to undergo radiosurgery were scanned prior to treatment using computed tomography (CT), three-dimensional (3D) rotational angiography (3DRA), T2 weighted and blood oxygenation level dependent echo planar imaging MRI. Tasks were chosen on the basis of lesion location by considering those areas which could be potentially close to treatment targets. Functional data were superimposed on 3DRA and CT used for treatment planning. The procedure for the localization of fMRI areas was validated by direct cortical stimulation on 38 AVM and tumor patients undergoing conventional surgery. Treatment plans studied with and without considering fOARs were significantly different, in particular with respect to both maximum dose and dose volume histograms; consideration of the fOARs allowed quality indices of treatment plans to remain almost constant or to improve in four out of five cases compared to plans with no consideration of fOARs. In conclusion, the presented method provides an accurate tool for the integration of functional information into AVM radiosurgery, which might help to minimize undesirable side effects and to make radiosurgery less invasive.« less
Anand, Sonia S; Tu, Jack V; Awadalla, Philip; Black, Sandra; Boileau, Catherine; Busseuil, David; Desai, Dipika; Després, Jean-Pierre; de Souza, Russell J; Dummer, Trevor; Jacquemont, Sébastien; Knoppers, Bartha; Larose, Eric; Lear, Scott A; Marcotte, Francois; Moody, Alan R; Parker, Louise; Poirier, Paul; Robson, Paula J; Smith, Eric E; Spinelli, John J; Tardif, Jean-Claude; Teo, Koon K; Tusevljak, Natasa; Friedrich, Matthias G
2016-07-27
The Canadian Alliance for Healthy Hearts and Minds (CAHHM) is a pan-Canadian, prospective, multi-ethnic cohort study being conducted in Canada. The overarching objective of the CAHHM is to understand the association of socio-environmental and contextual factors (such as societal structure, activity, nutrition, social and tobacco environments, and access to health services) with cardiovascular risk factors, subclinical vascular disease, and cardiovascular and other chronic disease outcomes. Participants between 35 and 69 years of age are being recruited from existing cohorts and a new First Nations Cohort to undergo a detailed assessment of health behaviours (including diet and physical activity), cognitive function, assessment of their local home and workplace environments, and their health services access and utilization. Physical measures including weight, height, waist/hip circumference, body fat percentage, and blood pressure are collected. In addition, eligible participants undergo magnetic resonance imaging (MRI) of the brain, heart, carotid artery and abdomen to detect early subclinical vascular disease and ectopic fat deposition. CAHHM is a prospective cohort study designed to investigate the impact of community level factors, individual health behaviours, and access to health services, on cognitive function, subclinical vascular disease, fat distribution, and the development of chronic diseases among adults living in Canada.
Long-term effects of musical training and functional plasticity in salience system.
Luo, Cheng; Tu, Shipeng; Peng, Yueheng; Gao, Shan; Li, Jianfu; Dong, Li; Li, Gujing; Lai, Yongxiu; Li, Hong; Yao, Dezhong
2014-01-01
Musicians undergoing long-term musical training show improved emotional and cognitive function, which suggests the presence of neuroplasticity. The structural and functional impacts of the human brain have been observed in musicians. In this study, we used data-driven functional connectivity analysis to map local and distant functional connectivity in resting-state functional magnetic resonance imaging data from 28 professional musicians and 28 nonmusicians. Compared with nonmusicians, musicians exhibited significantly greater local functional connectivity density in 10 regions, including the bilateral dorsal anterior cingulate cortex, anterior insula, and anterior temporoparietal junction. A distant functional connectivity analysis demonstrated that most of these regions were included in salience system, which is associated with high-level cognitive control and fundamental attentional process. Additionally, musicians had significantly greater functional integration in this system, especially for connections to the left insula. Increased functional connectivity between the left insula and right temporoparietal junction may be a response to long-term musical training. Our findings indicate that the improvement of salience network is involved in musical training. The salience system may represent a new avenue for exploration regarding the underlying foundations of enhanced higher-level cognitive processes in musicians.
Turner, Monroe P; Hubbard, Nicholas A; Himes, Lyndahl M; Faghihahmadabadi, Shawheen; Hutchison, Joanna L; Bennett, Ilana J; Motes, Michael A; Haley, Robert W; Rypma, Bart
Cognitive slowing is a prevalent symptom observed in Gulf War Illness (GWI). The present study assessed the extent to which functional connectivity between dorsolateral prefrontal cortex (DLPFC) and other task-relevant brain regions was predictive of GWI-related cognitive slowing. GWI patients (n = 54) and healthy veteran controls (n = 29) were assessed on performance of a processing speed task (the Digit Symbol Substitution Task; DSST) while undergoing functional magnetic resonance imaging (fMRI). GWI patients were slower on the DSST relative to controls. Bilateral DLPFC connectivity with task-relevant nodes was altered in GWI patients compared to healthy controls during DSST performance. Moreover, hyperconnectivity in these networks predicted GWI-related increases in reaction time on the DSST, whereas hypoconnectivity did not. These results suggest that GWI-related cognitive slowing reflects reduced efficiency in cortical networks.
The Role of Diffusivity Quenching in Flux-transport Dynamo Models
NASA Astrophysics Data System (ADS)
Guerrero, Gustavo; Dikpati, Mausumi; de Gouveia Dal Pino, Elisabete M.
2009-08-01
In the nonlinear phase of a dynamo process, the back-reaction of the magnetic field upon the turbulent motion results in a decrease of the turbulence level and therefore in a suppression of both the magnetic field amplification (the α-quenching effect) and the turbulent magnetic diffusivity (the η-quenching effect). While the former has been widely explored, the effects of η-quenching in the magnetic field evolution have rarely been considered. In this work, we investigate the role of the suppression of diffusivity in a flux-transport solar dynamo model that also includes a nonlinear α-quenching term. Our results indicate that, although for α-quenching the dependence of the magnetic field amplification with the quenching factor is nearly linear, the magnetic field response to η-quenching is nonlinear and spatially nonuniform. We have found that the magnetic field can be locally amplified in this case, forming long-lived structures whose maximum amplitude can be up to ~2.5 times larger at the tachocline and up to ~2 times larger at the center of the convection zone than in models without quenching. However, this amplification leads to unobservable effects and to a worse distribution of the magnetic field in the butterfly diagram. Since the dynamo cycle period increases when the efficiency of the quenching increases, we have also explored whether the η-quenching can cause a diffusion-dominated model to drift into an advection-dominated regime. We have found that models undergoing a large suppression in η produce a strong segregation of magnetic fields that may lead to unsteady dynamo-oscillations. On the other hand, an initially diffusion-dominated model undergoing a small suppression in η remains in the diffusion-dominated regime.
Modified Mason number for charged paramagnetic colloidal suspensions
NASA Astrophysics Data System (ADS)
Du, Di; Hilou, Elaa; Biswal, Sibani Lisa
2016-06-01
The dynamics of magnetorheological fluids have typically been described by the Mason number, a governing parameter defined as the ratio between viscous and magnetic forces in the fluid. For most experimental suspensions of magnetic particles, surface forces, such as steric and electrostatic interactions, can significantly influence the dynamics. Here we propose a theory of a modified Mason number that accounts for surface forces and show that this modified Mason number is a function of interparticle distance. We demonstrate that this modified Mason number is accurate in describing the dynamics of a rotating pair of paramagnetic colloids of identical or mismatched sizes in either high or low salt solutions. The modified Mason number is confirmed to be pseudoconstant for particle pairs and particle chains undergoing a stable-metastable transition during rotation. The interparticle distance term can be calculated using theory or can be measured experimentally. This modified Mason number is more applicable to magnetorheological systems where surface forces are not negligible.
The Blume-Capel model on hierarchical lattices: Exact local properties
NASA Astrophysics Data System (ADS)
Rocha-Neto, Mário J. G.; Camelo-Neto, G.; Nogueira, E., Jr.; Coutinho, S.
2018-03-01
The local properties of the spin one ferromagnetic Blume-Capel model defined on hierarchical lattices with dimension two and three are obtained by a numerical recursion procedure and studied as functions of the temperature and the reduced crystal-field parameter. The magnetization and the density of sites in the configuration S = 0 state are carefully investigated at low temperature in the region of the phase diagram that presents the phenomenon of phase reentrance. Both order parameters undergo transitions from the ferromagnetic to the ordered paramagnetic phase with abrupt discontinuities that decrease along the phase boundary at low temperatures. The distribution of magnetization in a typical profile was determined on the transition line presenting a broad multifractal spectrum that narrows towards the fractal limit (single point) as the discontinuities of the order parameters grow towards a maximum. The amplitude of the order-parameter discontinuities and the narrowing of the multifractal spectra were used to delimit the low temperature interval for the possible locus of the tricritical point.
Model of vortex dynamics in superconducting films in two-coil measurements of the coherence length
NASA Astrophysics Data System (ADS)
Lemberger, Thomas; Loh, Yen Lee
In two-coil measurements on superconducting films, a magnetic field from a small coil is applied to the center of the film. When the amplitude of the ac field is increased, the film undergoes a transition from the ``Meissner'' state to a state with vortices and antivortices. Ultimately, the vortex density matches the applied magnetic field and field screening is negligible. Experimentally, the field at the transition is related to the superconducting coherence length, although a full theory of the relationship is lacking. We show that the mutual inductance between drive and pickup coils, on opposite sides of the film, as a function of ac field amplitude is well-described by a phenomenological model in which vortices and antivortices appear together in the film at the radius where the induced supercurrent is strongest, and then they move through a landscape of moderately strong vortex pinning sites. Work at OSU supported by DOE-Basic Energy Sciences through Grant No. FG02-08ER46533.
Magnetic field dependence of Griffith phase and magnetocaloric effect in Ca0.85Dy0.15MnO3
NASA Astrophysics Data System (ADS)
Nag, Ripan; Sarkar, Bidyut; Pal, Sudipta
2018-03-01
Temperature and Magnetic field dependent magnetization properties of electron doped polycrystalline sample Ca0.85Dy0.15MnO3 (CDMO) prepared by solid state reaction method have been studied. The sample undergoes ferromagnetic to paramagnetic phase transition at about 111k. From the study of magnetic properties in terms of Arrot plots it is observed that the phase transition is of 2nd order. The Griffith phase behavior of the sample is suppressed with the increase of the applied magnetic field strength H. We have estimated the magnetic entropy change from experimental magnetization and temperature data. For a magnetic field change of 8000 Oe, the maximum value of magnetic entropy change arrives at a value of 1.126 J-kg-1 k-1 in this magnetocaloric material.
Iatrogenic hyperthermia during cardiac magnetic resonance imaging.
Kussman, Barry D; Mulkern, Robert V; Holzman, Robert S
2004-10-01
We report the occurrence of accidental hyperthermia in a young child undergoing anesthesia for cardiac magnetic resonance imaging. Although the tendency during anesthesia is to develop hypothermia, the absorbed radiofrequency energy from magnetic resonance scanning is added to metabolic energy and must be balanced by appropriate heat loss to maintain normothermia. In addition to stressing the clinical importance of temperature monitoring, this report suggests that the recommended specific absorption rates to prevent excessive patient heating may need to be revised for infants and young children.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Koplak, O. V.; Shteynman, E. A.; Tereschenko, A. N.
2015-09-15
A correlation between the temperature dependences of the D1-line intensity of dislocation luminescence and the magnetic moment of plastically deformed isotopically enriched crystals {sup 29}Si:B is found. It is established that the magnetic susceptibility of the deformed crystals obtained by integration of the spectra of electron spin resonance and the D1-line intensity undergo similar nonmonotonic variations with temperature varying in the range of 20–32 K.
Wang, Zhaolu; van Veluw, Susanne J; Wong, Adrian; Liu, Wenyan; Shi, Lin; Yang, Jie; Xiong, Yunyun; Lau, Alexander; Biessels, Geert Jan; Mok, Vincent C T
2016-10-01
It was recently demonstrated that cerebral microinfarcts (CMIs) can be detected in vivo using 3.0 tesla (T) magnetic resonance imaging. We investigated the prevalence, risk factors, and the longitudinal cognitive consequence of cortical CMIs on 3.0T magnetic resonance imaging, in patients with ischemic stroke or transient ischemic attack. A total of 231 patients undergoing 3.0T magnetic resonance imaging were included. Montreal Cognitive Assessment was used to evaluate global cognitive functions and cognitive domains (memory, language, and attention visuospatial and executive functions). Cognitive changes were represented by the difference in Montreal Cognitive Assessment score between baseline and 28-month after stroke/transient ischemic attack. The cross-sectional and longitudinal associations between cortical CMIs and cognitive functions were explored using ANCOVA and regression models. Cortical CMIs were observed in 34 patients (14.7%), including 13 patients with acute (hyperintense on diffusion-weighted imaging) and 21 with chronic CMIs (isointense on diffusion-weighted imaging). Atrial fibrillation was a risk factor for all cortical CMIs (odds ratio, 4.8; 95% confidence interval, 1.5-14.9; P=0.007). Confluent white matter hyperintensities was associated with chronic CMIs (odds ratio, 2.8; 95% confidence interval, 1.0-7.8; P=0.047). The presence of cortical CMIs at baseline was associated with worse visuospatial functions at baseline and decline over 28-month follow-up (β=0.5; 95% confidence interval, 0.1-1.0; P=0.008, adjusting for brain atrophy, white matter hyperintensities, lacunes, and microbleeds). Cortical CMIs are a common finding in patients with stroke/transient ischemic attack. Associations between CMI with atrial fibrillation and white matter hyperintensities suggest that these lesions have a heterogeneous cause, involving microembolism and cerebral small vessel disease. CMI seemed to preferentially impact visuospatial functions as assessed by a cognitive screening test. © 2016 American Heart Association, Inc.
Beca, John; Gunn, Julia K; Coleman, Lee; Hope, Ayton; Reed, Peter W; Hunt, Rodney W; Finucane, Kirsten; Brizard, Christian; Dance, Brieana; Shekerdemian, Lara S
2013-03-05
Abnormalities on magnetic resonance imaging scans are common both before and after surgery for congenital heart disease in early infancy. The aim of this study was to prospectively investigate the nature, timing, and consequences of brain injury on magnetic resonance imaging in a cohort of young infants undergoing surgery for congenital heart disease both with and without cardiopulmonary bypass. A total of 153 infants undergoing surgery for congenital heart disease at <8 weeks of age underwent serial magnetic resonance imaging scans before and after surgery and at 3 months of age, as well as neurodevelopmental assessment at 2 years of age. White matter injury (WMI) was the commonest type of injury both before and after surgery. It occurred in 20% of infants before surgery and was associated with a less mature brain. New WMI after surgery was present in 44% of infants and at similar rates after surgery with or without cardiopulmonary bypass. The most important association was diagnostic group (P<0.001). In infants having arch reconstruction, the use and duration of circulatory arrest were significantly associated with new WMI. New WMI was also associated with the duration of cardiopulmonary bypass, postoperative lactate level, brain maturity, and WMI before surgery. Brain immaturity but not brain injury was associated with impaired neurodevelopment at 2 years of age. New WMI is common after surgery for congenital heart disease and occurs at the same rate in infants undergoing surgery with and without cardiopulmonary bypass. New WMI is associated with diagnostic group and, in infants undergoing arch surgery, the use of circulatory arrest.
Mullin, Jeffrey P; Soni, Pranay; Lee, Sungho; Jehi, Lara; Naduvil Valappi, Ahsan Moosa; Bingaman, William; Gonzalez-Martinez, Jorge
2016-09-01
In some cases of refractory epilepsy, hemispherectomy is the final invasive treatment option. However, predictors of postoperative hemiparesis in these patients have not been widely studied. To investigate how the volumetric analysis of cerebral peduncles and cerebellar hemispheres in patients who have undergone hemispherectomy may determine prognostic implications for postoperative hemiparesis. Twenty-two patients who underwent hemispherectomy at our institution were retrospectively included. Using iPlan/BrainLAB (BrainLAB, Feldkirchen, Germany) imaging software and a semiautomatic voxel-based segmentation method, we calculated the preoperative cerebral peduncle and cerebellar hemisphere volumes. Cerebral peduncle and cerebellar hemisphere ratios were compared between patients with worsened or unchanged/better hemiparesis postoperatively. The ratios of ipsilateral/contralateral cerebral peduncles (0.570 vs 0.828; P = .02) and contralateral/ipsilateral cerebellar hemispheres (0.885 vs 1.031; P = .009) were significantly lower in patients who had unchanged/improved hemiparesis postoperatively compared with patients who had worsened hemiparesis. Relative risk of worsening hemiparesis was significantly higher in patients with a cerebral peduncle ratio < 0.7 (relative risk, 4.3; P = .03) or a cerebellar ratio < 1.0 (relative risk, 6.4; P = .006). Although patients who undergo hemispherectomy are heterogeneous, we report a method of predicting postoperative hemiparesis using only standard volumetric magnetic resonance imaging. This information could be used in preoperative discussions with patients and families to help better understand that chance of retaining baseline motor function. CST, corticospinal tractfMRI, functional magnetic resonance imagingTMS, transcranial magnetic stimulation.
van Dijk, Vincent F; Delnoy, Peter Paul H M; Smit, Jaap Jan J; Ramdat Misier, R Anand; Elvan, Arif; van Es, H Wouter; Rensing, Benno J W M; Raciti, Giovanni; Boersma, Lucas V A
2017-07-01
Modern pacemakers are designed to allow patients to undergo magnetic resonance imaging (MRI) under a set of specific conditions. Aim of this study is to provide confirmatory evidence of safety and performance of a new pacing system (ImageReady™, Boston Scientific) in patients undergoing 1.5 and 3T MRI. Two prospective, nonrandomized, single-arm studies were designed to provide confirmatory data of no impact of MRI on device function, lead parameters, and patient conditions in subjects implanted with the system undergoing a clinically non-indicated 1.5T and 3T MRI, respectively. Device measurements were done within 1 hour before and after the scan and at 1 month follow-up. Thirty-two subjects underwent MRI visit (17 subjects with 1.5T MRI and 15 subjects with 3T MRI). There were no unanticipated adverse effects related to the pacemaker. Device measurements taken pre- and post-MRI scan did not show any clinical relevant change that could indicate an effect of the MRI on the device or at the lead-tissue interface (RV threshold change: 0.01 ± 0.13 V, P = 0.60; RA threshold change: 0.01 ± 0.11 V, P = 0.53; R wave change: -0.44 ± 1.73 mV, P = 0.36; R wave change: 0.12 ± 1.67 mV, P = 0.73), with data confirmed at 1-month follow-up visit. The study documented safety of the pacing system in the 1.5T and 3T MRI environment by showing no adverse events related to device or MRI scan. Additional data are required to cover the more complex scenarios involving different diagnostic needs, conditions of use, clinical conditions, and new emerging technologies. © 2017 Wiley Periodicals, Inc.
Particle acceleration at shocks in the presence of a braided magnetic field
NASA Astrophysics Data System (ADS)
Kirk, J. G.; Duffy, P.; Gallant, Y. A.
1997-05-01
The theory of first order Fermi acceleration at shock fronts assumes charged particles undergo spatial diffusion in a uniform magnetic field. If, however, the magnetic field is not uniform, but has a stochastic or braided structure, the transport of charged particles across the average direction of the field is more complicated. Assuming quasi-linear behaviour of the field lines, the particles undergo sub-diffusion (
Toller, Gianina; Adhimoolam, Babu; Grunwald, Thomas; Huppertz, Hans-Jürgen; König, Kristina; Jokeit, Hennric
2015-01-01
Nonvisual spatial navigation functional magnetic resonance imaging (fMRI) may help clinicians determine memory lateralization in blind individuals with refractory mesial temporal lobe epilepsy (MTLE). We report on an exceptional case of a congenitally blind woman with late-onset left MTLE undergoing presurgical memory fMRI. To activate mesial temporal structures despite the lack of visual memory, the patient was requested to recall familiar routes using nonvisual multisensory and verbal cues. Our findings demonstrate the diagnostic value of a nonvisual fMRI task to lateralize MTLE despite congenital blindness and may therefore contribute to the risk assessment for postsurgical amnesia in rare cases with refractory MTLE and accompanying congenital blindness.
NASA Astrophysics Data System (ADS)
McConville, S. L.; Ronald, K.; Speirs, D. C.; Gillespie, K. M.; Phelps, A. D. R.; Cross, A. W.; Bingham, R.; Robertson, C. W.; Whyte, C. G.; He, W.; King, M.; Bryson, R.; Vorgul, I.; Cairns, R. A.; Kellett, B. J.
2014-05-01
Auroral Kilometric Radiation (AKR) emissions occur at frequencies ~300kHz polarised in the X-mode with efficiencies ~1-2% [1,2] in the auroral density cavity in the polar regions of the Earth's magnetosphere, a region of low density plasma ~3200km above the Earth's surface, where electrons are accelerated down towards the Earth whilst undergoing magnetic compression. As a result of this magnetic compression the electrons acquire a horseshoe distribution function in velocity space. Previous theoretical studies have predicted that this distribution is capable of driving the cyclotron maser instability. To test this theory a scaled laboratory experiment was constructed to replicate this phenomenon in a controlled environment, [3-5] whilst 2D and 3D simulations are also being conducted to predict the experimental radiation power and mode, [6-9]. The experiment operates in the microwave frequency regime and incorporates a region of increasing magnetic field as found at the Earth's pole using magnet solenoids to encase the cylindrical interaction waveguide through which an initially rectilinear electron beam (12A) was accelerated by a 75keV pulse. Experimental results showed evidence of the formation of the horseshoe distribution function. The radiation was produced in the near cut-off TE01 mode, comparable with X-mode characteristics, at 4.42GHz. Peak microwave output power was measured ~35kW and peak efficiency of emission ~2%, [3]. A Penning trap was constructed and inserted into the interaction waveguide to enable generation of a background plasma which would lead to closer comparisons with the magnetospheric conditions. Initial design and measurements are presented showing the principle features of the new geometry.
[Propofol for sedation in pediatric magnetic resonance imaging investigations].
Reinhold, P; Graichen, B
1999-01-01
Magnetic Resonance Imaging requires immobilisation of the patients without excitement due to acoustic irritation. During childhood this is hardly to guarantee without anaesthesia or sedation. The problem is the magnetic field strength, which interferes with the monitoring devices and the anaesthesia machines interrupting the function and can produce thermal injury, but additionally the tools will cause image degradation. MR Imaging was done in 46 children with a mean age of 50.9 months (0.06 to 129) in a sedation with propofol during spontaneous breathing. The induction dose of propofol was 3.0 mg/kg bodyweight and the repetition dose was 1.0 mg/kg. During the radiological examination and the time of emergence the children were monitored with a MRI-compatible fiberoptic pulseoximeter (NONIN), a capnography by naso-pharyngeal canula (OHMEDA) and a noninvasive blood pressure oscillometer (CRITICON). The monitors were located outside the 0.5 Tesla area and were connected to the patient via extension tubing. Additionally there was a clinical observation by a present anaesthesiologist. In all children the investigation has been realized without any problem. Haemodynamics, ventilation and oxygenation have been in a normal range. Only 2 of the 186 sequences had to be repeated. After a mean time of investigation of 29 minutes (10 to 55) the emergence time until purposeful reaction was 7.7 minutes (5 to 20) and until full orientation was 13.4 minutes (5 to 30). This regime of sedation for children undergoing Magnetic Resonance Imaging is safe and suitable independent of age: there is a good control of vital functions, a minimum of side effects and a fine recovery characteristic with short times of emergence.
Pacemakers and implantable cardioverter defibrillators--general and anesthetic considerations.
Rapsang, Amy G; Bhattacharyya, Prithwis
2014-01-01
A pacemaking system consists of an impulse generator and lead or leads to carry the electrical impulse to the patient's heart. Pacemaker and implantable cardioverter defibrillator codes were made to describe the type of pacemaker or implantable cardioverter defibrillator implanted. Indications for pacing and implantable cardioverter defibrillator implantation were given by the American College of Cardiologists. Certain pacemakers have magnet-operated reed switches incorporated; however, magnet application can have serious adverse effects; hence, devices should be considered programmable unless known otherwise. When a device patient undergoes any procedure (with or without anesthesia), special precautions have to be observed including a focused history/physical examination, interrogation of pacemaker before and after the procedure, emergency drugs/temporary pacing and defibrillation, reprogramming of pacemaker and disabling certain pacemaker functions if required, monitoring of electrolyte and metabolic disturbance and avoiding certain drugs and equipments that can interfere with pacemaker function. If unanticipated device interactions are found, consider discontinuation of the procedure until the source of interference can be eliminated or managed and all corrective measures should be taken to ensure proper pacemaker function should be done. Post procedure, the cardiac rate and rhythm should be monitored continuously and emergency drugs and equipments should be kept ready and consultation with a cardiologist or a pacemaker-implantable cardioverter defibrillator service may be necessary. Copyright © 2013 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.
Spectral density mapping at multiple magnetic fields suitable for 13C NMR relaxation studies
NASA Astrophysics Data System (ADS)
Kadeřávek, Pavel; Zapletal, Vojtěch; Fiala, Radovan; Srb, Pavel; Padrta, Petr; Přecechtělová, Jana Pavlíková; Šoltésová, Mária; Kowalewski, Jozef; Widmalm, Göran; Chmelík, Josef; Sklenář, Vladimír; Žídek, Lukáš
2016-05-01
Standard spectral density mapping protocols, well suited for the analysis of 15N relaxation rates, introduce significant systematic errors when applied to 13C relaxation data, especially if the dynamics is dominated by motions with short correlation times (small molecules, dynamic residues of macromolecules). A possibility to improve the accuracy by employing cross-correlated relaxation rates and on measurements taken at several magnetic fields has been examined. A suite of protocols for analyzing such data has been developed and their performance tested. Applicability of the proposed protocols is documented in two case studies, spectral density mapping of a uniformly labeled RNA hairpin and of a selectively labeled disaccharide exhibiting highly anisotropic tumbling. Combination of auto- and cross-correlated relaxation data acquired at three magnetic fields was applied in the former case in order to separate effects of fast motions and conformational or chemical exchange. An approach using auto-correlated relaxation rates acquired at five magnetic fields, applicable to anisotropically moving molecules, was used in the latter case. The results were compared with a more advanced analysis of data obtained by interpolation of auto-correlated relaxation rates measured at seven magnetic fields, and with the spectral density mapping of cross-correlated relaxation rates. The results showed that sufficiently accurate values of auto- and cross-correlated spectral density functions at zero and 13C frequencies can be obtained from data acquired at three magnetic fields for uniformly 13C -labeled molecules with a moderate anisotropy of the rotational diffusion tensor. Analysis of auto-correlated relaxation rates at five magnetic fields represents an alternative for molecules undergoing highly anisotropic motions.
Sollmann, Nico; Kelm, Anna; Ille, Sebastian; Schröder, Axel; Zimmer, Claus; Ringel, Florian; Meyer, Bernhard; Krieg, Sandro M
2018-06-01
OBJECTIVE Awake surgery combined with intraoperative direct electrical stimulation (DES) and intraoperative neuromonitoring (IONM) is considered the gold standard for the resection of highly language-eloquent brain tumors. Different modalities, such as functional magnetic resonance imaging (fMRI) or magnetoencephalography (MEG), are commonly added as adjuncts for preoperative language mapping but have been shown to have relevant limitations. Thus, this study presents a novel multimodal setup consisting of preoperative navigated transcranial magnetic stimulation (nTMS) and nTMS-based diffusion tensor imaging fiber tracking (DTI FT) as an adjunct to awake surgery. METHODS Sixty consecutive patients (63.3% men, mean age 47.6 ± 13.3 years) suffering from highly language-eloquent left-hemispheric low- or high-grade glioma underwent preoperative nTMS language mapping and nTMS-based DTI FT, followed by awake surgery for tumor resection. Both nTMS language mapping and DTI FT data were available for resection planning and intraoperative guidance. Clinical outcome parameters, including craniotomy size, extent of resection (EOR), language deficits at different time points, Karnofsky Performance Scale (KPS) score, duration of surgery, and inpatient stay, were assessed. RESULTS According to postoperative evaluation, 28.3% of patients showed tumor residuals, whereas new surgery-related permanent language deficits occurred in 8.3% of patients. KPS scores remained unchanged (median preoperative score 90, median follow-up score 90). CONCLUSIONS This is the first study to present a clinical outcome analysis of this very modern approach, which is increasingly applied in neurooncological centers worldwide. Although human language function is a highly complex and dynamic cortico-subcortical network, the presented approach offers excellent functional and oncological outcomes in patients undergoing surgery of lesions affecting this network.
Bigby, Sarah E; Carter, Jennifer E; Bauquier, Sébastien; Beths, Thierry
2016-09-01
Anesthesia protocols for patients with intracranial lesions need to provide hemodynamic stability, preserve cerebrovascular autoregulation, avoid increases in intracranial pressure, and facilitate a rapid recovery. Propofol total intravenous anesthesia (TIVA) maintains cerebral blood flow autoregulation and is considered superior to inhalant agents as an anesthetic protocol for patients with intracranial lesions. A propofol-based TIVA subsequent to premedication with medetomidine and diazepam was used in a king penguin ( Aptenodytes patagonicus ) undergoing magnetic resonance imaging of the brain after a new onset of seizures. This protocol provided a rapid and smooth induction and calm recovery in the penguin. When ventilation control is possible, propofol TIVA may be a superior choice to inhalant agents for anesthesia of birds with potential intracranial lesions.
Structural and magnetic transitions in spinel FeM n 2 O 4 single crystals
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nepal, Roshan; Zhang, Qiang; Dai, Samuel
Materials that form the spinel structure are known to exhibit geometric frustration, which can lead to magnetic frustration as well. Through magnetization and neutron diffraction measurements, we find that FeMn 2O 4 undergoes one structural and two magnetic transitions. The structural transition occurs at T s ~595K from cubic at high temperatures to tetragonal at low temperatures. Here, two magnetic transitions are ferrimagnetic at T FI–1 ~373K and T FI–2 ~50K, respectively. Further investigation of the specific heat, thermal conductivity, and Seebeck coefficient confirms both magnetic transitions. Of particular interest is that there is a significant magnetic contribution to themore » low-temperature specific heat and thermal conductivity, providing a unique system to study heat transport by magnetic excitations.« less
Structural and magnetic transitions in spinel FeM n 2 O 4 single crystals
Nepal, Roshan; Zhang, Qiang; Dai, Samuel; ...
2018-01-11
Materials that form the spinel structure are known to exhibit geometric frustration, which can lead to magnetic frustration as well. Through magnetization and neutron diffraction measurements, we find that FeMn 2O 4 undergoes one structural and two magnetic transitions. The structural transition occurs at T s ~595K from cubic at high temperatures to tetragonal at low temperatures. Here, two magnetic transitions are ferrimagnetic at T FI–1 ~373K and T FI–2 ~50K, respectively. Further investigation of the specific heat, thermal conductivity, and Seebeck coefficient confirms both magnetic transitions. Of particular interest is that there is a significant magnetic contribution to themore » low-temperature specific heat and thermal conductivity, providing a unique system to study heat transport by magnetic excitations.« less
Bekelis, Kimon; Missios, Symeon; MacKenzie, Todd A
2018-01-24
The quality of physicians practicing in hospitals recognized for nursing excellence by the American Nurses Credentialing Center has not been studied before. We investigated whether Magnet hospital recognition is associated with higher quality of physicians performing neurosurgical procedures. We performed a cohort study of patients undergoing neurosurgical procedures from 2009-2013, who were registered in the New York Statewide Planning and Research Cooperative System (SPARCS) database. Propensity score adjusted multivariable regression models were used to adjust for known confounders, with mixed effects methods to control for clustering at the facility level. An instrumental variable analysis was used to control for unmeasured confounding and simulate the effect of a randomized trial. During the study period, 185,277 patients underwent neurosurgical procedures, and met the inclusion criteria. Of these, 66,607 (35.6%) were hospitalized in Magnet hospitals, and 118,670 (64.4%) in non-Magnet institutions. Instrumental variable analysis demonstrated that undergoing neurosurgical operations in Magnet hospitals was associated with a 13.6% higher chance of being treated by a physician with superior performance in terms of mortality (95% CI, 13.2% to 14.1%), and a 4.3% higher chance of being treated by a physician with superior performance in terms of length-of-stay (LOS) (95% CI, 3.8% to 4.7%) in comparison to non-Magnet institutions. The same associations were present in propensity score adjusted mixed effects models. Using a comprehensive all-payer cohort of neurosurgical patients in New York State we identified an association of Magnet hospital recognition with superior physician performance.
Kinetic Alfven turbulence: Electron and ion heating by particle-in-cell simulations
NASA Astrophysics Data System (ADS)
Gary, S. P.; Hughes, R. S.; Wang, J.; Parashar, T. N.
2017-12-01
Three-dimensional particle-in-cell simulations of the forward cascade of decaying kinetic Alfvén turbulence have been carried out as an initial-value problem on a collisionless, homogeneous, magnetized, electron-ion plasma model with betae = betai =0.50 and mi/me=100 where subscripts e and i represent electrons and ions respectively. Initial anisotropic narrowband spectra of relatively long wavelength modes with approximately gyrotropic distributions in kperp undergo a forward cascade to broadband spectra of magnetic fluctuations at shorter wavelengths. Maximum electron and ion heating rates are computed as functions of the initial fluctuating magnetic field energy density eo on the range 0.05 < eo < 0.50. In contrast to dissipation by whistler turbulence, the maximum ion heating rate due to kinetic Alfvén turbulence is substantially greater than the maximum electron heating rate. Furthermore, ion heating as well as electron heating due to kinetic Alfvén turbulence scale approximately with eo. Finally, electron heating leads to anisotropies of the type T||e> Tperpe where the parallel and perpendicular symbols refer to directions parallel and perpendicular, respectively, to the background magnetic field, whereas the heated ions remain relatively isotropic. This implies that, for the range of eo values considered, the Landau wave-particle resonance is a likely heating mechanism for the electrons and may also contribute to ion heating.
Design Considerations for Proposed Fermilab Integrable RCS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eldred, Jeffrey; Valishev, Alexander
2017-03-02
Integrable optics is an innovation in particle accelerator design that provides strong nonlinear focusing while avoiding parametric resonances. One promising application of integrable optics is to overcome the traditional limits on accelerator intensity imposed by betatron tune-spread and collective instabilities. The efficacy of high-intensity integrable accelerators will be undergo comprehensive testing over the next several years at the Fermilab Integrable Optics Test Accelerator (IOTA) and the University of Maryland Electron Ring (UMER). We propose an integrable Rapid-Cycling Synchrotron (iRCS) as a replacement for the Fermilab Booster to achieve multi-MW beam power for the Fermilab high-energy neutrino program. We provide amore » overview of the machine parameters and discuss an approach to lattice optimization. Integrable optics requires arcs with integer-pi phase advance followed by drifts with matched beta functions. We provide an example integrable lattice with features of a modern RCS - long dispersion-free drifts, low momentum compaction, superperiodicity, chromaticity correction, separate-function magnets, and bounded beta functions.« less
Psychological reactions in women undergoing fetal magnetic resonance imaging.
Leithner, Katharina; Pörnbacher, Susanne; Assem-Hilger, Eva; Krampl, Elisabeth; Ponocny-Seliger, Elisabeth; Prayer, Daniela
2008-02-01
To investigate women's psychological reactions when undergoing fetal magnetic resonance imaging (MRI), and to estimate whether certain groups, based on clinical and sociodemographic variables, differ in their subjective experiences with fetal MRI and in their anxiety levels related to the scanning procedure. This study is a prospective cohort investigation of 62 women before and immediately after fetal MRI. Anxiety levels and subjective experiences were measured by questionnaires. Groups based on clinical and sociodemographic variables were compared with regard to anxiety levels and to the scores on the Prescan and Postscan Imaging Distress Questionnaire. Anxiety scores before fetal MRI were 8.8 points higher than those of the female, nonclinical, norm population (P<.001). The severity of the referral diagnosis showed a linearly increasing effect on anxiety level before MRI (weighted linear term: F1,59=5.325, P=.025). Magnetic resonance imaging was experienced as unpleasant by 33.9% (95% confidence interval [CI] 21.2-46.6%) and as hardly bearable by 4.8% (95% CI 0-17.5%) of the women. Physical restraint (49.9%, 95% CI 37.4-62.4%), noise level (53.2%, 95% CI 40.7-65.7%), anxiety for the infant (53.2%, 95% CI 40.7-65.7%), and the duration of the examination (51.6%, 95% CI 39.1-64.1%) were major distressing factors. Women who undergo fetal magnetic resonance imaging experience considerable distress, especially those with poor fetal prognoses. Ongoing technical developments, such as a reduction of noise, shortening the duration of the MRI, and a more comfortable position in open MRI machines, may have the potential to improve the subjective experiences of women during fetal MRI. III.
On the Biomechanics of Vaginal Birth and Common Sequelae
Ashton-Miller, James A.; DeLancey, John O.L.
2010-01-01
Approximately 11% of U.S. women undergo surgery for pelvic floor dysfunction, including genital organ prolapse and urinary and fecal incontinence. The major risk factor for developing these conditions is giving vaginal birth. Vaginal birth is a remarkable event about which little is known from a biomechanical perspective. We first review the functional anatomy of the female pelvic floor, the normal loads acting on the pelvic floor in activities of daily living, and the functional capacity of the pelvic floor muscles. Computer models show that the stretch ratio in the pelvic floor muscles can reach an extraordinary 3.26 by the end of the second stage of labor. Magnetic resonance images provide evidence that show that the pelvic floor regions experiencing the most stretch are at the greatest risk for injury, especially in forceps deliveries. A conceptual model suggests how these injuries may lead to the most common form of pelvic organ prolapse, a cystocele. PMID:19591614
Josephson-junction array in an irrational magnetic field: A superconducting glass
DOE Office of Scientific and Technical Information (OSTI.GOV)
Halsey, T.C.
1985-08-26
A model is used to show that a Josephson junction array in an irrational magnetic field undergoes a glass transition for finite cooling rate. At zero temperature the resultant glassy state possesses a nonzero critical current. The low-temperature behavior of the system can be modeled by a spin-wave theory. The relevance of these results for real experiments on arrays is discussed.
NASA Astrophysics Data System (ADS)
Ruiz, Milton; Shapiro, Stuart L.
2017-10-01
Inspiraling and merging binary neutron stars are not only important source of gravitational waves, but also promising candidates for coincident electromagnetic counterparts. These systems are thought to be progenitors of short gamma-ray bursts (sGRBs). We have shown previously that binary neutron star mergers that undergo delayed collapse to a black hole surrounded by a weighty magnetized accretion disk can drive magnetically powered jets. We now perform magnetohydrodynamic simulations in full general relativity of binary neutron stars mergers that undergo prompt collapse to explore the possibility of jet formation from black hole- light accretion disk remnants. We find that after t -tBH˜26 (MNS/1.8 M⊙) ms (MNS is the ADM mass) following prompt black hole formation, there is no evidence of mass outflow or magnetic field collimation. The rapid formation of the black hole following merger prevents magnetic energy from approaching force-free values above the magnetic poles, which is required for the launching of a jet by the usual Blandford-Znajek mechanism. Detection of gravitational waves in coincidence with sGRBs may provide constraints on the nuclear equation of state (EOS): the fate of an NSNS merger-delayed or prompt collapse, and hence the appearance or nonappearance of an sGRB-depends on a critical value of the total mass of the binary, and this value is sensitive to the EOS.
Stable spin domains in a nondegenerate ultracold gas
NASA Astrophysics Data System (ADS)
Graham, S. D.; Niroomand, D.; Ragan, R. J.; McGuirk, J. M.
2018-05-01
We study the stability of two-domain spin structures in an ultracold gas of magnetically trapped 87Rb atoms above quantum degeneracy. Adding a small effective magnetic field gradient stabilizes the domains via coherent collective spin rotation effects, despite negligibly perturbing the potential energy relative to the thermal energy. We demonstrate that domain stabilization is accomplished through decoupling the dynamics of longitudinal magnetization, which remains in time-independent domains, from transverse magnetization, which undergoes a purely transverse spin wave trapped within the domain wall. We explore the effect of temperature and density on the steady-state domains, and compare our results to a hydrodynamic solution to a quantum Boltzmann equation.
Magnetic flux conservation in an imploding plasma.
García-Rubio, F; Sanz, J; Betti, R
2018-01-01
The theory of magnetic flux conservation is developed for a subsonic plasma implosion and used to describe the magnetic flux degradation in the MagLIF concept [S. A. Slutz et al., Phys. Plasmas 17, 056303 (2010)10.1063/1.3333505]. Depending on the initial magnetic Lewis and Péclet numbers and the electron Hall parameter, the implosion falls into either a superdiffusive regime in which the magnetization decreases or a magnetized regime in which the magnetization increases. Scaling laws for magnetic field, temperature, and magnetic flux losses in the hot spot of radius R are obtained for both regimes. The Nernst velocity convects the magnetic field outwards, pushing it against the liner and enhancing the magnetic field diffusion, thereby reducing the magnetic field compression and degrading the implosion performance. However, in the magnetized regime, the core of the hot spot becomes magnetically insulated and undergoes an ideal adiabatic compression (T∼R^{-4/3} compared to T∼R^{-2/3} without magnetic field), while the detrimental Nernst term is confined to the outer part of the hot spot. Its effect is drastically reduced, improving the magnetic flux conservation.
Magnetic flux conservation in an imploding plasma
NASA Astrophysics Data System (ADS)
García-Rubio, F.; Sanz, J.; Betti, R.
2018-01-01
The theory of magnetic flux conservation is developed for a subsonic plasma implosion and used to describe the magnetic flux degradation in the MagLIF concept [S. A. Slutz et al., Phys. Plasmas 17, 056303 (2010), 10.1063/1.3333505]. Depending on the initial magnetic Lewis and Péclet numbers and the electron Hall parameter, the implosion falls into either a superdiffusive regime in which the magnetization decreases or a magnetized regime in which the magnetization increases. Scaling laws for magnetic field, temperature, and magnetic flux losses in the hot spot of radius R are obtained for both regimes. The Nernst velocity convects the magnetic field outwards, pushing it against the liner and enhancing the magnetic field diffusion, thereby reducing the magnetic field compression and degrading the implosion performance. However, in the magnetized regime, the core of the hot spot becomes magnetically insulated and undergoes an ideal adiabatic compression (T ˜R-4 /3 compared to T ˜R-2 /3 without magnetic field), while the detrimental Nernst term is confined to the outer part of the hot spot. Its effect is drastically reduced, improving the magnetic flux conservation.
Coexistence of spin crossover and magnetic ordering in a dendrimeric Fe(III) complex
NASA Astrophysics Data System (ADS)
Vorobeva, V. E.; Domracheva, N. E.; Pyataev, A. V.; Gruzdev, M. S.; Chervonova, U. V.
2015-01-01
The magnetic properties of a new dendrimeric spin crossover Fe(III) complex, [Fe(L)2]+PF6-, where L = 3,5-di[3,4,5-tris(tetradecyloxy) benzoyloxy]benzoyl-4-salicylidene-N-ethyl-N-ethylene-diamine, are reported for the first time. EPR studies show that this compound undergoes a gradual spin transition in the temperature range 70-300 K and has antiferromagnetic ordering below 10 K. Mössbauer spectroscopy at 5 K confirms the presence of magnetic ordering in the dendrimeric iron complex.
Effects of Renal Denervation on Renal Artery Function in Humans: Preliminary Study
Doltra, Adelina; Hartmann, Arthur; Stawowy, Philipp; Goubergrits, Leonid; Kuehne, Titus; Wellnhofer, Ernst; Gebker, Rolf; Schneeweis, Christopher; Schnackenburg, Bernhard; Esler, Murray; Fleck, Eckart; Kelle, Sebastian
2016-01-01
Aim To study the effects of RD on renal artery wall function non-invasively using magnetic resonance. Methods and Results 32 patients undergoing RD were included. A 3.0 Tesla magnetic resonance of the renal arteries was performed before RD and after 6-month. We quantified the vessel sharpness of both renal arteries using a quantitative analysis tool (Soap-Bubble®). In 17 patients we assessed the maximal and minimal cross-sectional area of both arteries, peak velocity, mean flow, and renal artery distensibility. In a subset of patients wall shear stress was assessed with computational flow dynamics. Neither renal artery sharpness nor renal artery distensibility differed significantly. A significant increase in minimal and maximal areas (by 25.3%, p = 0.008, and 24.6%, p = 0.007, respectively), peak velocity (by 16.9%, p = 0.021), and mean flow (by 22.4%, p = 0.007) was observed after RD. Wall shear stress significantly decreased (by 25%, p = 0.029). These effects were observed in blood pressure responders and non-responders. Conclusions RD is not associated with adverse effects at renal artery level, and leads to an increase in cross-sectional areas, velocity and flow and a decrease in wall shear stress. PMID:27003912
THE DISCOVERY OF SOLAR-LIKE ACTIVITY CYCLES BEYOND THE END OF THE MAIN SEQUENCE?
DOE Office of Scientific and Technical Information (OSTI.GOV)
Route, Matthew, E-mail: mroute@purdue.edu
2016-10-20
The long-term magnetic behavior of objects near the cooler end of the stellar main sequence is poorly understood. Most theoretical work on the generation of magnetism in these ultracool dwarfs (spectral type ≥M7 stars and brown dwarfs) suggests that their magnetic fields should not change in strength and direction. Using polarized radio emission measurements of their magnetic field orientations, I demonstrate that these cool, low-mass, fully convective objects appear to undergo magnetic polarity reversals analogous to those that occur on the Sun. This powerful new technique potentially indicates that the patterns of magnetic activity displayed by the Sun continue tomore » exist, despite the fully convective interiors of these objects, in contravention of several leading theories of the generation of magnetic fields by internal dynamos.« less
Haeck, Joost D E; Verouden, Niels J W; Kuijt, Wichert J; Koch, Karel T; Van Straalen, Jan P; Fischer, Johan; Groenink, Maarten; Bilodeau, Luc; Tijssen, Jan G P; Krucoff, Mitchell W; De Winter, Robbert J
2010-04-15
The purpose of the present study was to determine the prognostic value of N-terminal pro-brain natriuretic peptide (NT-pro-BNP), among other serum biomarkers, on cardiac magnetic resonance (CMR) imaging parameters of cardiac function and infarct size in patients with ST-segment elevation myocardial infarction undergoing primary percutaneous coronary intervention. We measured NT-pro-BNP, cardiac troponin T, creatinine kinase-MB fraction, high-sensitivity C-reactive protein, and creatinine on the patients' arrival at the catheterization laboratory in 206 patients with ST-segment elevation myocardial infarction. The NT-pro-BNP levels were divided into quartiles and correlated with left ventricular function and infarct size measured by CMR imaging at 4 to 6 months. Compared to the lower quartiles, patients with nonanterior wall myocardial infarction in the highest quartile of NT-pro-BNP (> or = 260 pg/ml) more often had a greater left ventricular end-systolic volume (68 vs 39 ml/m(2), p <0.001), a lower left ventricular ejection fraction (42% vs 54%, p <0.001), a larger infarct size (9 vs 4 g/m(2), p = 0.002), and a larger number of transmural segments (11% of segments vs 3% of segments, p <0.001). Multivariate analysis revealed that a NT-pro-BNP level of > or = 260 pg/ml was the strongest independent predictor of left ventricular ejection fraction in patients with nonanterior wall myocardial infarction compared to the other serum biomarkers (beta = -5.8; p = 0.019). In conclusion, in patients with nonanterior wall myocardial infarction undergoing primary percutaneous coronary intervention, an admission NT-pro-BNP level of > or = 260 pg/ml was a strong, independent predictor of left ventricular function assessed by CMR imaging at follow-up. Our findings suggest that NT-pro-BNP, a widely available biomarker, might be helpful in the early risk stratification of patients with nonanterior wall myocardial infarction. Copyright 2010 Elsevier Inc. All rights reserved.
Magnetism in structures with ferromagnetic and superconducting layers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhaketov, V. D.; Nikitenko, Yu. V., E-mail: nikiten@nf.jinr.ru; Radu, F.
2017-01-15
The influence of superconductivity on ferromagnetism in the layered Ta/V/Fe{sub 1–x}V{sub x}/V/Fe{sub 1–x}V{sub x}/Nb/Si structures consisting of ferromagnetic and superconducting layers is studied using polarized neutron reflection and scattering. It is experimentally shown that magnetic structures with linear sizes from 5 nm to 30 μm are formed in these layered structures at low temperatures. The magnetization of the magnetic structures is suppressed by superconductivity at temperatures below the superconducting transition temperatures in the V and Nb layers. The magnetic states of the structures are shown to undergo relaxation over a wide magnetic-field range, which is caused by changes in themore » states of clusters, domains, and Abrikosov vortices.« less
Evolution of magnetism in LnCuGa3 (Ln = La-Nd, Sm-Gd) studied via μSR and specific heat
NASA Astrophysics Data System (ADS)
Graf, M. J.; Hettinger, J. D.; Nemeth, K.; Dally, R.; Baines, C.; Subbarao, U.; Peter, S. C.
2017-12-01
Muon spin rotation/relaxation (μSR) and specific heat measurements are presented for polycrystalline LnCuGa3, with Ln = La-Nd, and Sm-Gd. All materials undergo magnetic ordering transitions, apart from non-magnetic LaCuGa3, and PrCuGa3, which shows the onset of short range correlations below 3 K but no long-range magnetic order down to T = 25 mK. While magnetic order in the Ce and Nd compounds is incommensurate with the lattice, the order is commensurate for the Sm and Eu compounds. The strong damping in GdCuGa3 prevents us from determining the nature of magnetism in that system. SmCuGa3 exhibits two precessional frequencies, which appear at different temperatures, suggesting inhomogeneous magnetic ordering or a second magnetic/structural phase transition.
Magalang, Ulysses J.; Richards, Kathryn; McCarthy, Beth; Fathala, Ahmed; Khan, Meena; Parinandi, Narasimham; Raman, Subha V.
2009-01-01
Study Objectives. There are few data on the effects of continuous positive airway pressure (CPAP) therapy on the structural and functional characteristics of the right heart in patients with obstructive sleep apnea (OSA). We sought to leverage the advantages of cardiac magnetic resonance imaging (CMR) and hypothesized that CPAP treatment would improve right ventricular (RV) function in a group of patients with OSA who were free of other comorbid conditions. Methods. Patients with severe (apnea-hypopnea index ≥ 30/h) untreated OSA were prospectively enrolled. CMR included 3-dimensional measurement of biventricular size and function, and rest/stress myocardial perfusion and was performed at baseline and after 3 months of CPAP therapy. Results. Fifteen patients with mild to moderate desaturation were enrolled; 2 could not undergo CMR due to claustrophobia and obesity. There were significant decreases in the Epworth Sleepiness Scale score (p < 0.0001) and RV end-systolic and RV end-diastolic volumes (p < 0.05) with CPAP. There was a trend toward improvement in RV ejection fraction, but the improvement did not reach statistical significance. Other measures such as left ventricular volumes, left ventricular ejection fraction, myocardial perfusion reserve index, and thickness of the interventricular septum and ventricular free wall did not change significantly. Conclusions: This preliminary study found that CPAP treatment decreases RV volumes in patients with severe OSA who are otherwise healthy. CMR offers a novel technique to determine the effects of CPAP on ventricular structure and function in patients with OSA. A randomized controlled study is needed to confirm the results of our study. Citation: Magalang UJ; Richards K; McCarthy B; Fathala A; Khan M; Parinandi N; Raman SV. Continuous positive airway pressure therapy reduces right ventricular volume in patients with obstructive sleep apnea: a cardiovascular magnetic resonance study. J Clin Sleep Med 2009;5(2):110-114. PMID:19968042
Seeking New Treatments for Endometriosis
... NICHD Research Information Find a Study More Information Pharmacology Condition Information NICHD Research Information Find a Study ... no known history of endometriosis, who undergo pelvic magnetic resonance imaging to identify whether they have endometriosis or another ...
Low-temperature physics: Chaos in the cold
NASA Astrophysics Data System (ADS)
Julienne, Paul S.
2014-03-01
A marriage between theory and experiment has shown that ultracold erbium atoms trapped with laser light and subjected to a magnetic field undergo collisions that are characterized by quantum chaos. See Letter p.475
Giant magnetostriction effect near onset of spin reorientation in MnBi
DOE Office of Scientific and Technical Information (OSTI.GOV)
Choi, Y.; Ryan, P. J.; McGuire, Michael A.
In materials undergoing spontaneous symmetry breaking transitions, the emergence of multiple competing order parameters is pervasive. Employing in-field x-ray diffraction, we investigate the temperature and magnetic field dependence of the crystallographic structure of MnBi, elucidating the microscopic interplay between lattices and spin. The hexagonal phase of MnBi undergoes a spin reorientation transition (TSR), whereby the easy axis direction changes from the c axis to the basal plane. Across TSR, an abrupt symmetry change is accompanied by a clear sign change in the magnetostrictive coefficient, revealing that this transition corresponds to the onset of the spin reorientation. In the vicinity ofmore » TSR, a significantly larger in-plane magnetostrictive effect is observed, presenting the emergence of an intermediate phase that is highly susceptible to an applied magnetic field. X-ray linear dichroism shows that asymmetric Bi and Mn p orbitals do not play a role in the spin reorientation. Furthermore, this work suggests that the spin reorientation is caused by structural modification rather than changes in the local electronic configuration, providing a strategy for manipulating the magnetic anisotropy by external strain.« less
Giant magnetostriction effect near onset of spin reorientation in MnBi
Choi, Y.; Ryan, P. J.; McGuire, Michael A.; ...
2018-05-11
In materials undergoing spontaneous symmetry breaking transitions, the emergence of multiple competing order parameters is pervasive. Employing in-field x-ray diffraction, we investigate the temperature and magnetic field dependence of the crystallographic structure of MnBi, elucidating the microscopic interplay between lattices and spin. The hexagonal phase of MnBi undergoes a spin reorientation transition (TSR), whereby the easy axis direction changes from the c axis to the basal plane. Across TSR, an abrupt symmetry change is accompanied by a clear sign change in the magnetostrictive coefficient, revealing that this transition corresponds to the onset of the spin reorientation. In the vicinity ofmore » TSR, a significantly larger in-plane magnetostrictive effect is observed, presenting the emergence of an intermediate phase that is highly susceptible to an applied magnetic field. X-ray linear dichroism shows that asymmetric Bi and Mn p orbitals do not play a role in the spin reorientation. Furthermore, this work suggests that the spin reorientation is caused by structural modification rather than changes in the local electronic configuration, providing a strategy for manipulating the magnetic anisotropy by external strain.« less
Giant magnetostriction effect near onset of spin reorientation in MnBi
NASA Astrophysics Data System (ADS)
Choi, Y.; Ryan, P. J.; McGuire, M. A.; Sales, B. C.; Kim, J.-W.
2018-05-01
In materials undergoing spontaneous symmetry breaking transitions, the emergence of multiple competing order parameters is pervasive. Employing in-field x-ray diffraction, we investigate the temperature and magnetic field dependence of the crystallographic structure of MnBi, elucidating the microscopic interplay between lattices and spin. The hexagonal phase of MnBi undergoes a spin reorientation transition (TSR), whereby the easy axis direction changes from the c axis to the basal plane. Across TSR, an abrupt symmetry change is accompanied by a clear sign change in the magnetostrictive coefficient, revealing that this transition corresponds to the onset of the spin reorientation. In the vicinity of TSR, a significantly larger in-plane magnetostrictive effect is observed, presenting the emergence of an intermediate phase that is highly susceptible to an applied magnetic field. X-ray linear dichroism shows that asymmetric Bi and Mn p orbitals do not play a role in the spin reorientation. This work suggests that the spin reorientation is caused by structural modification rather than changes in the local electronic configuration, providing a strategy for manipulating the magnetic anisotropy by external strain.
Magnetic energy storage and conversion in the solar atmosphere
NASA Technical Reports Server (NTRS)
Spicer, D. S.; Mariska, J. T.; Boris, J. P.
1986-01-01
According to the approach employed in this investigation, particularly important simple configurations of magnetic field and plasma are identified, and it is attempted to achieve an understanding of the large-scale dynamic processes and transformations which these systems can undergo. Fundamental concepts are discussed, taking into account aspects of magnetic energy generation, ideal MHD theory, non-MHD properties, the concept of 'anomalous' resistivity, and global electrodynamic coupling. Questions of magnetically controlled energy conversion are examined, giving attention to magnetic modifications of plasma transport, the transition region structure and flows, channeling and acceleration of plasma, channeling and dissipation of MHD waves, and anomalous dissipation of field-aligned currents. A description of the characteristics of magnetohydrodynamic energy conversion is also provided, and outstanding questions are discussed.
Steering microtubule shuttle transport with dynamically controlled magnetic fields
Mahajan, K. D.; Ruan, G.; Dorcéna, C. J.; ...
2016-03-23
Nanoscale control of matter is critical to the design of integrated nanosystems. Here, we describe a method to dynamically control directionality of microtubule (MT) motion using programmable magnetic fields. MTs are combined with magnetic quantum dots (i.e., MagDots) that are manipulated by external magnetic fields provided by magnetic nanowires. MT shuttles thus undergo both ATP-driven and externally-directed motion with a fluorescence component that permits simultaneous visualization of shuttle motion. This technology is used to alter the trajectory of MTs in motion and to pin MT motion. Ultimately, such an approach could be used to evaluate the MT-kinesin transport system andmore » could serve as the basis for improved lab-on-a-chip technologies based on MT transport.« less
ALS superbend magnet performance
DOE Office of Scientific and Technical Information (OSTI.GOV)
Marks, Steve; Zbasnik, John; Byrne, Warren
2001-12-10
The Lawrence Berkeley National Laboratory has been engaged in the design, construction and testing of four superconducting dipoles (Superbends) that are installed in three arcs of the Advanced Light Source (ALS), with the fourth magnet as a spare. This represents a major upgrade to the ALS providing an enhanced flux and brightness at photon energies above 10 keV. In preparation for installation, an extensive set of tests and measurements have been conducted to characterize the magnetic and cryogenic performance of the Superbends and to fiducialize them for accurate placement in the ALS storage ring. The magnets are currently installed, andmore » the storage ring is undergoing final commissioning. This paper will present the results of magnetic and cryogenic testing.« less
Influence of volume magnetostriction on the thermodynamic properties of Ni-Mn-Ga shape memory alloys
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kosogor, Anna; Institute of Magnetism, 36-b, Vernadsky Str., Kyiv 03142; Donetsk Institute for Physics and Engineering, Kyiv 03028
2015-10-07
In the present article, the thermodynamic properties of Ni-Mn-Ga ferromagnetic shape memory alloys exhibiting the martensitic transformations (MTs) above and below Curie temperature are compared. It is shown that when MT goes below Curie temperature, the elastic and thermal properties of alloy noticeably depend on magnetization value due to spontaneous volume magnetostriction. However, the separation of magnetic parts from the basic characteristics of MT is a difficult task, because the volume magnetostriction does not qualitatively change the transformational behaviour of alloy. This problem is solved for several Ni-Mn-Ga alloys by means of the quantitative theoretical analysis of experimental data obtainedmore » in the course of stress-strain tests. For each alloy, the entropy change and the transformation heat evolved in the course of MT are evaluated, first, from the results of stress-strain tests and, second, from differential scanning calorimetry data. For all alloys, a quantitative agreement between the values obtained in two different ways is observed. It is shown that the magnetic part of transformation heat exceeds the non-magnetic one for the Ni-Mn-Ga alloys undergoing MTs in ferromagnetic state, while the elevated values of transformation heat measured for the alloys undergoing MTs in paramagnetic state are caused by large MT strains.« less
Influence of volume magnetostriction on the thermodynamic properties of Ni-Mn-Ga shape memory alloys
NASA Astrophysics Data System (ADS)
Kosogor, Anna; L'vov, Victor A.; Cesari, Eduard
2015-10-01
In the present article, the thermodynamic properties of Ni-Mn-Ga ferromagnetic shape memory alloys exhibiting the martensitic transformations (MTs) above and below Curie temperature are compared. It is shown that when MT goes below Curie temperature, the elastic and thermal properties of alloy noticeably depend on magnetization value due to spontaneous volume magnetostriction. However, the separation of magnetic parts from the basic characteristics of MT is a difficult task, because the volume magnetostriction does not qualitatively change the transformational behaviour of alloy. This problem is solved for several Ni-Mn-Ga alloys by means of the quantitative theoretical analysis of experimental data obtained in the course of stress-strain tests. For each alloy, the entropy change and the transformation heat evolved in the course of MT are evaluated, first, from the results of stress-strain tests and, second, from differential scanning calorimetry data. For all alloys, a quantitative agreement between the values obtained in two different ways is observed. It is shown that the magnetic part of transformation heat exceeds the non-magnetic one for the Ni-Mn-Ga alloys undergoing MTs in ferromagnetic state, while the elevated values of transformation heat measured for the alloys undergoing MTs in paramagnetic state are caused by large MT strains.
Amidi, Ali; Hosseini, S M Hadi; Leemans, Alexander; Kesler, Shelli R; Agerbæk, Mads; Wu, Lisa M; Zachariae, Robert
2017-12-01
Cisplatin-based chemotherapy may have neurotoxic effects within the central nervous system. The aims of this study were 1) to longitudinally investigate the impact of cisplatin-based chemotherapy on whole-brain networks in testicular cancer patients undergoing treatment and 2) to explore whether possible changes are related to decline in cognitive functioning. Sixty-four newly orchiectomized TC patients underwent structural magnetic resonance imaging (T1-weighted and diffusion-weighted imaging) and cognitive testing at baseline prior to further treatment and again at a six-month follow-up. At follow-up, 22 participants had received cisplatin-based chemotherapy (CT) while 42 were in active surveillance (S). Brain structural networks were constructed for each participant, and network properties were investigated using graph theory and longitudinally compared across groups. Cognitive functioning was evaluated using standardized neuropsychological tests. All statistical tests were two-sided. Compared with the S group, the CT group demonstrated altered global and local brain network properties from baseline to follow-up as evidenced by decreases in important brain network properties such as small-worldness (P = .04), network clustering (P = .04), and local efficiency (P = .02). In the CT group, poorer overall cognitive performance was associated with decreased small-worldness (r = -0.46, P = .04) and local efficiency (r = -0.51, P = .02), and verbal fluency was associated with decreased local efficiency (r = -0.55, P = .008). Brain structural networks may be disrupted following treatment with cisplatin-based chemotherapy. Impaired brain networks may underlie poorer performance over time on both specific and nonspecific cognitive functions in patients undergoing chemotherapy. To the best of our knowledge, this is the first study to longitudinally investigate changes in structural brain networks in a cancer population, providing novel insights regarding the neurobiological mechanisms of cancer-related cognitive impairment.
Tikàsz, Andràs; Potvin, Stéphane; Richard-Devantoy, Stéphane; Lipp, Olivier; Hodgins, Sheilagh; Lalonde, Pierre; Lungu, Ovidiu; Dumais, Alexandre
2017-11-09
We investigated the influence of anger processing on cognitive control in male schizophrenia patients presenting violent behaviors. We recruited 23 patients without and 24 patients with (SCZ+V) a history of violent behaviors, as well as 22 healthy non-violent men. Participants were administered an affective (angry-neutral faces) Go/NoGo task while undergoing functional magnetic resonance imaging. We found a reduced activation in the dorsolateral prefrontal cortex in SCZ+V patients specifically when inhibiting a response while viewing angry faces. These results show an inability of SCZ+V to recruit a core region of the (inhibitory) cognitive control network in the context of anger. Copyright © 2017 Elsevier B.V. All rights reserved.
Exploiting pressure to induce a "guest-blocked" spin transition in a framework material
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sciortino, Natasha F.; Ragon, Florence; Zenere, Katrina A.
A new functionalized 1,2,4-trizole ligand 4-[(E)-2-(5-methyl-2-thienyl)vinyl]-1,2,4-triazole (thiome) was prepared to assess the structural and magnetic consequence of ligand steric bulk in the resultant framework material [FeIIPd(CN)4(thiome)2]·2(H2O) (A·2(H2O)). Structural studies reveal that the pore size is smaller than realted 2-D Hofmann-type materials and that the water molecules can be reversibly removed with retention of the porous host framework. Magnetic measurements show ‘on-off’ sensing to the presence of water. The hydrated phase is spin crossover (SCO) inactive whereas the dehydrated phase undergoes an abrupt and hysteretic one-step spin transition. Partial dehydration (A·n(H2O), 0 ≤ n ≤ 2) leads to systematically varying spinmore » transition temperatures further demonstrating qualitative sensing. These studies suggest that the SCO properties are governed by internal lattice pressure effects. Variable pressure structure and magnetic studies on the hydrated phase, A·2(H2O), reveal that such internal guest pressure effects can be overcome with moderate external pressure application (0 – 0.68 GPa) resulting in a two-step spin transition at ambient temperatures at 0.68 GPa.« less
Magnetic Orders of LaTiO3 and YTiO3 Under Epitaxial Strain: a First-Principles study
NASA Astrophysics Data System (ADS)
Weng, Yakui; Huang, Xin; Tang, Yankun; Dong, Shuai
2014-03-01
Perovskite RTiO3 family is a typical Mott-insulator with localized 3d electrons. In this work, the epitaxial strain effects on the ground magnetic orders of LaTiO3 and YTiO3 films have been studied using the first-principles density-functional theory. For the YTiO3 films, A-type antiferromagnetic order emerges against the original ferromagnetic order under the in-plane compressive strain by LaAlO3 (001) substrate, although the A-type antiferromagnetic order does not exist in any RTiO3 bulks. Then, for the LaTiO3 films under the compressive strain, e.g. LaTiO3 films grown on LaAlO3, LaGaO3, and SrTiO3 substrates, undergo a phase transition from the original G-type antiferromagnetism to A-type antiferromagnetism. While under the tensile strain, e.g. grown on the BaTiO3 and LaScO3 substrate, LaTiO3 films show a tendency to transit to the C-type antiferromagnetism. Furthermore, our calculations find that the magnetic transitions under epitaxial strain do not change the insulating fact of LaTiO3 and YTiO3.
NASA Astrophysics Data System (ADS)
Sen, Abhijit; Roy, Soumyabrata; Peter, Sebastian C.; Paul, Arpita; Waghmare, Umesh V.; Sundaresan, A.
2018-02-01
We report a detailed experimental and theoretical investigation of structural, optical, magnetic and magnetothermal properties of single crystals of a new organic-inorganic hybrid (C2H5NH3)2CoCl4. Grown by slow evaporation method at room temperature, the compound crystallizes in centrosymmetric orthorhombic structure (Pnma) which undergoes a reversible phase transition at 235/241 K (cooling/heating) to noncentrosymmetric P212121 space group symmetry associated with order-disorder transformation of carbon atoms of the ammonium cations as well as molecular rearrangement. Electronic absorption spectra of the compound are typical of geometrically distorted [CoCl4]2- tetrahedra having spin-orbit coupling effect. The isolated nature of [CoCl4]2- tetrahedra in the crystal reflect in paramagnetic behaviour of the compound. Interestingly, field induced spin flipping behaviour is observed at low temperature. First principles density functional calculations reveal weak magnetic interaction among cobalt spins with ferromagnetic state being the ground state. The entropy change associated with the spin flipping has been experimentally estimated by magnetic and heat capacity measurements which has a maximum value of 16 J Kg-1 K-1 at 2.5 K under 7 T magnetic field. To the best of our knowledge, this is the first report on magnetocaloric effect observed in an organic-inorganic halide compound. The estimated value is sizable and is comparable to that of well-known transition metal molecular cluster magnets Mn12 or Fe14. The overall findings promise to enlighten new routes to design and constitute multifunctional organic-inorganic halide materials.
Ille, Sebastian; Kulchytska, Nataliia; Sollmann, Nico; Wittig, Regina; Beurskens, Eva; Butenschoen, Vicki M; Ringel, Florian; Vajkoczy, Peter; Meyer, Bernhard; Picht, Thomas; Krieg, Sandro M
2016-10-01
The resection of left-sided perisylvian brain lesions harbors the risk of postoperative aphasia. Because it is known that language function can shift between hemispheres in brain tumor patients, the preoperative knowledge of the patient's language dominance could be helpful. We therefore investigated the hemispheric language dominance by repetitive navigated transcranial magnetic stimulation (rTMS) and surgery-related deficits of language function. We pooled the bicentric language mapping data of 80 patients undergoing the resection of left-sided perisylvian brain lesions in our two university neurosurgical departments. We calculated error rates (ERs; ER = errors per stimulations) for both hemispheres and defined the hemispheric dominance ratio (HDR) as the quotient of the left- and right-sided ER (HDR >1= left dominant; HDR <1= right dominant). The course of the patient's language function was evaluated and correlated with the preoperative HDR. Only three of 80 patients (4%) presented with permanent surgery-related aphasia and 24 patients (30%) with transient surgery-related aphasia. The mean HDR (± standard deviation) of patients with new aphasia after five days was significantly higher (1.68±1.07) than the HDR of patients with no new language deficit (1.37±1.08) (p=0.0482). With a predefined cut-off value of 0.5 for HDR, we achieved a sensitivity for predicting new aphasia of 100%. A higher preoperative HDR significantly correlates with an increased risk for transient aphasia. Moreover, the intensive preoperative workup in this study led to a considerably low rate of permanent aphasia. Copyright © 2016 Elsevier Ltd. All rights reserved.
Soriano, Brian D; Hoch, Martin; Ithuralde, Alejandro; Geva, Tal; Powell, Andrew J; Kussman, Barry D; Graham, Dionne A; Tworetzky, Wayne; Marx, Gerald R
2008-04-08
Quantitative assessment of ventricular volumes and mass in pediatric patients with single-ventricle physiology would aid clinical management, but it is difficult to obtain with 2-dimensional echocardiography. The purpose of the present study was to compare matrix-array 3-dimensional echocardiography (3DE) measurements of single-ventricle volumes, mass, and ejection fraction with those measured by cardiac magnetic resonance (CMR) in young patients. Twenty-nine patients (median age, 7 months) with a functional single ventricle undergoing CMR under general anesthesia were prospectively enrolled. The 3DE images were acquired at the conclusion of the CMR. Twenty-seven of 29 3DE data sets (93%) were optimal for 3DE assessment. Two blinded and independent observers performed 3DE measurements of volume, mass, and ejection fraction. The 3DE end-diastolic volume correlated well (r=0.96) but was smaller than CMR by 9% (P<0.01), and 3DE ejection fraction was smaller than CMR by 11% (P<0.01). There was no significant difference in measurements of end-systolic volume and mass. The 3DE interobserver differences for mass and volumes were not significant except for ejection fraction (8% difference; P<0.05). Intraobserver differences were not significant. In young pediatric patients with a functional single ventricle, matrix-array 3DE measurements of mass and volumes compare well with those obtained by CMR. 3DE will provide an important modality for the serial analysis of ventricular size and performance in young patients with functional single ventricles.
A Context Note: Choice, Diversity and Desegregation in Massachusetts.
ERIC Educational Resources Information Center
Zerchykov, Ross
1986-01-01
Presents and discusses enrollment statistics for nine Massachusetts school systems undergoing desegregation. Focuses on Boston, Worcester, Springfield, Lowell, and Cambridge. Describes each system as successfully promoting desegregation through magnet schools and parental choice. (KH)
Dental materials and magnetic resonance imaging.
Hubálková, Hana; Hora, Karel; Seidl, Zdenek; Krásenský, Jan
2002-09-01
The objective of this investigation was to evaluate the reaction of selected dental materials in the magnetic field of a magnetic resonance imaging device to determine a possible health risk. The following dental materials were tested in vitro during magnetic resonance imaging: 15 dental alloys, four dental implants, one surgical splint and two wires for fixation of maxillofacial fractures. Possible artefacts (corresponding with magnetic properties), heating and force effects were tested. Results concerning movement and heating were in agreement with the literature. The artefacts seen were significant: for the surgical splint, a spherical artefact with a diameter of 55 mm; for the wires, up to 22 mm; and for the dental blade implant, an artefact of 28 x 20 mm. The results of our tests of selected dental appliances indicate that their presence in the human organism is safe for patients undergoing magnetic resonance imaging procedures. The presence of artefacts can substantially influence the magnetic resonance imaging results.
Magnetic vortex nucleation modes in static magnetic fields
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vanatka, Marek; Urbanek, Michal; Jira, Roman
The magnetic vortex nucleation process in nanometer- and micrometer-sized magnetic disks undergoes several phases with distinct spin configurations called the nucleation states. Before formation of the final vortex state, small submicron disks typically proceed through the so-called C-state while the larger micron-sized disks proceed through the more complicated vortex-pair state or the buckling state. This work classifies the nucleation states using micromagnetic simulations and provides evidence for the stability of vortex-pair and buckling states in static magnetic fields using magnetic imaging techniques and electrical transport measurements. Lorentz Transmission Electron Microscopy and Magnetic Transmission X-ray Microscopy are employed to reveal themore » details of spin configuration in each of the nucleation states. We further show that it is possible to unambiguously identify these states by electrical measurements via the anisotropic magnetoresistance effect. Combination of the electrical transport and magnetic imaging techniques confirms stability of a vortex-antivortex-vortex spin configuration which emerges from the buckling state in static magnetic fields.« less
Magnetic vortex nucleation modes in static magnetic fields
Vanatka, Marek; Urbanek, Michal; Jira, Roman; ...
2017-10-03
The magnetic vortex nucleation process in nanometer- and micrometer-sized magnetic disks undergoes several phases with distinct spin configurations called the nucleation states. Before formation of the final vortex state, small submicron disks typically proceed through the so-called C-state while the larger micron-sized disks proceed through the more complicated vortex-pair state or the buckling state. This work classifies the nucleation states using micromagnetic simulations and provides evidence for the stability of vortex-pair and buckling states in static magnetic fields using magnetic imaging techniques and electrical transport measurements. Lorentz Transmission Electron Microscopy and Magnetic Transmission X-ray Microscopy are employed to reveal themore » details of spin configuration in each of the nucleation states. We further show that it is possible to unambiguously identify these states by electrical measurements via the anisotropic magnetoresistance effect. Combination of the electrical transport and magnetic imaging techniques confirms stability of a vortex-antivortex-vortex spin configuration which emerges from the buckling state in static magnetic fields.« less
Epitaxial strain-mediated spin-state transitions: can we switch off magnetism?
NASA Astrophysics Data System (ADS)
Rondinelli, James; Spaldin, Nicola
2008-03-01
We use first-principles density functional theory calculations to explore spin-state transitions in epitaxially strained LaCoO3. While high-spin to low-spin state transitions in minerals are common in geophysics, where pressures can reach over 200 GPa, we explore whether heteroepitaxial strain can achieve similar transitions with moderate strain in thin films. LaCoO3 is known to undergo a low-spin (S=0, t2g^6eg^0) to intermediate-spin (S=1, t2g^5eg^1) or high-spin (S=2, t2g^4eg^2) state transition with increasing temperature, and thus makes it a promising candidate material for strain-mediated spin transitions. Here we discuss the physics of the low-spin transition and changes in the electronic structure of LaCoO3, most notably, the metal-insulator transition that accompanies the spin-state transitions with epitaxial strain. As thin film growth techniques continue to reach atomic-level precision, we suggest this is another approach for controlling magnetism in complex oxide heterostructures.
Quantum-mechanical treatment of an electron undergoing synchrotron radiation.
NASA Technical Reports Server (NTRS)
White, D.
1972-01-01
The problem of an electron moving perpendicular to an intense magnetic field is approached from the framework of quantum mechanics. A numerical solution to the related rate equations describing the probabilities of occupation of the electron's energy states is put forth along with the expected errors involved. The quantum-mechanical approach is found to predict a significant amount of energy broadening with time for an initially monoenergetic electron beam entering a region of an intense magnetic field as long as the product of initial energy and magnetic field is of order 50 MG BeV or larger.
Bistability and chaos in the Taylor-Green dynamo.
Yadav, Rakesh K; Verma, Mahendra K; Wahi, Pankaj
2012-03-01
Using direct numerical simulations, we study dynamo action under Taylor-Green forcing for a magnetic Prandtl number of 0.5. We observe bistability with weak- and strong-magnetic-field branches. Both the dynamo branches undergo subcritical dynamo transition. We also observe a host of dynamo states including constant, periodic, quasiperiodic, and chaotic magnetic fields. One of the chaotic states originates through a quasiperiodic route with phase locking, while the other chaotic attractor appears to follow the Newhouse-Ruelle-Takens route to chaos. We also observe intermittent transitions between quasiperiodic and chaotic states for a given Taylor-Green forcing.
Viggiano, Maria Pia; Giganti, Fiorenza; Rossi, Arianna; Di Feo, Daniele; Vagnoli, Laura; Calcagno, Giovanna; Defilippi, Claudio
2015-01-01
Children undergoing magnetic resonance imaging examination frequently experience anxiety and fear before and during the scanning. The aim of the present study was to assess: i) whether and to what extent psychological interventions might reduce anxiety and fear levels; ii) whether the intervention is related to a decrease in the need for sedation. The interventions consisted of three activities: a clown show, dog interaction and live music. The emotional status (anxiety and fear) of the children was evaluated before and after the activities through a rating scale questionnaire. The results showed that the activities had high effectiveness in reducing the level of anxiety and fear and decreased the need for sedation in the experimental group compared to the control group. This approach proved to be a positive patient experience, helping to alleviate children’s anxiety and fear, decreasing the need for sedation, and was cost-effective. PMID:25918624
NASA Astrophysics Data System (ADS)
Ivanov, Konstantin L.; Sadovsky, Vladimir M.; Lukzen, Nikita N.
2015-08-01
In this work, we treat spin-selective recombination of a geminate radical pair (RP) in a spherical "microreactor," i.e., of a RP confined in a micelle, vesicle, or liposome. We consider the microreactor model proposed earlier, in which one of the radicals is located at the center of the micelle and the other one undergoes three-dimensional diffusion inside the micelle. In addition, we suggest a two-dimensional model, in which one of the radicals is located at the "pole" of the sphere, while the other one diffuses on the spherical surface. For this model, we have obtained a general analytical expression for the RP recombination yield in terms of the free Green function of two-dimensional diffusion motion. In turn, this Green function is expressed via the Legendre functions and thus takes account of diffusion over a restricted spherical surface and its curvature. The obtained expression allows one to calculate the RP recombination efficiency at an arbitrary magnetic field strength. We performed a comparison of the two models taking the same geometric parameters (i.e., the microreactor radius and the closest approach distance of the radicals), chemical reactivity, magnetic interactions in the RP and diffusion coefficient. Significant difference between the predictions of the two models is found, which is thus originating solely from the dimensionality effect: for different dimensionality of space, the statistics of diffusional contacts of radicals becomes different altering the reaction yield. We have calculated the magnetic field dependence of the RP reaction yield and chemically induced dynamic nuclear polarization of the reaction products at different sizes of the microreactor, exchange interaction, and spin relaxation rates. Interestingly, due to the intricate interplay of diffusional contacts of reactants and spin dynamics, the dependence of the reaction yield on the microreactor radius is non-monotonous. Our results are of importance for (i) interpreting experimental data for magnetic field effects on RP recombination in confined space and (ii) for describing kinetics of chemical reactions, which occur predominantly on the surfaces of biomembranes, i.e., lipid peroxidation reactions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ivanov, Konstantin L., E-mail: ivanov@tomo.nsc.ru; Lukzen, Nikita N.; Novosibirsk State University, Pirogova St. 2, Novosibirsk 630090
2015-08-28
In this work, we treat spin-selective recombination of a geminate radical pair (RP) in a spherical “microreactor,” i.e., of a RP confined in a micelle, vesicle, or liposome. We consider the microreactor model proposed earlier, in which one of the radicals is located at the center of the micelle and the other one undergoes three-dimensional diffusion inside the micelle. In addition, we suggest a two-dimensional model, in which one of the radicals is located at the “pole” of the sphere, while the other one diffuses on the spherical surface. For this model, we have obtained a general analytical expression formore » the RP recombination yield in terms of the free Green function of two-dimensional diffusion motion. In turn, this Green function is expressed via the Legendre functions and thus takes account of diffusion over a restricted spherical surface and its curvature. The obtained expression allows one to calculate the RP recombination efficiency at an arbitrary magnetic field strength. We performed a comparison of the two models taking the same geometric parameters (i.e., the microreactor radius and the closest approach distance of the radicals), chemical reactivity, magnetic interactions in the RP and diffusion coefficient. Significant difference between the predictions of the two models is found, which is thus originating solely from the dimensionality effect: for different dimensionality of space, the statistics of diffusional contacts of radicals becomes different altering the reaction yield. We have calculated the magnetic field dependence of the RP reaction yield and chemically induced dynamic nuclear polarization of the reaction products at different sizes of the microreactor, exchange interaction, and spin relaxation rates. Interestingly, due to the intricate interplay of diffusional contacts of reactants and spin dynamics, the dependence of the reaction yield on the microreactor radius is non-monotonous. Our results are of importance for (i) interpreting experimental data for magnetic field effects on RP recombination in confined space and (ii) for describing kinetics of chemical reactions, which occur predominantly on the surfaces of biomembranes, i.e., lipid peroxidation reactions.« less
Higgs transition from a magnetic Coulomb liquid to a ferromagnet in Yb₂Ti₂O₇.
Chang, Lieh-Jeng; Onoda, Shigeki; Su, Yixi; Kao, Ying-Jer; Tsuei, Ku-Ding; Yasui, Yukio; Kakurai, Kazuhisa; Lees, Martin Richard
2012-01-01
In a class of frustrated magnets known as spin ice, magnetic monopoles emerge as classical defects and interact via the magnetic Coulomb law. With quantum-mechanical interactions, these magnetic charges are carried by fractionalized bosonic quasi-particles, spinons, which can undergo Bose-Einstein condensation through a first-order transition via the Higgs mechanism. Here, we report evidence of a Higgs transition from a magnetic Coulomb liquid to a ferromagnet in single-crystal Yb(2)Ti(2)O(7). Polarized neutron scattering experiments show that the diffuse [111]-rod scattering and pinch-point features, which develop on cooling are suddenly suppressed below T(C)~0.21 K, where magnetic Bragg peaks and a full depolarization of the neutron spins are observed with thermal hysteresis, indicating a first-order ferromagnetic transition. Our results are explained on the basis of a quantum spin-ice model, whose high-temperature phase is effectively described as a magnetic Coulomb liquid, whereas the ground state shows a nearly collinear ferromagnetism with gapped spin excitations.
New MagViz Airport Liquid Analysis System Undergoes Testing
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2008-12-18
LOS ALAMOS, New Mexico, December 16, 2008—An innovative application of a technology first used for medical imaging may enhance airport security if Los Alamos National Laboratory scientists are successful. Los Alamos technologists have adapted Magnetic Res
Access disparities to Magnet hospitals for patients undergoing neurosurgical operations
Missios, Symeon; Bekelis, Kimon
2017-01-01
Background Centers of excellence focusing on quality improvement have demonstrated superior outcomes for a variety of surgical interventions. We investigated the presence of access disparities to hospitals recognized by the Magnet Recognition Program of the American Nurses Credentialing Center (ANCC) for patients undergoing neurosurgical operations. Methods We performed a cohort study of all neurosurgery patients who were registered in the New York Statewide Planning and Research Cooperative System (SPARCS) database from 2009–2013. We examined the association of African-American race and lack of insurance with Magnet status hospitalization for neurosurgical procedures. A mixed effects propensity adjusted multivariable regression analysis was used to control for confounding. Results During the study period, 190,535 neurosurgical patients met the inclusion criteria. Using a multivariable logistic regression, we demonstrate that African-Americans had lower admission rates to Magnet institutions (OR 0.62; 95% CI, 0.58–0.67). This persisted in a mixed effects logistic regression model (OR 0.77; 95% CI, 0.70–0.83) to adjust for clustering at the patient county level, and a propensity score adjusted logistic regression model (OR 0.75; 95% CI, 0.69–0.82). Additionally, lack of insurance was associated with lower admission rates to Magnet institutions (OR 0.71; 95% CI, 0.68–0.73), in a multivariable logistic regression model. This persisted in a mixed effects logistic regression model (OR 0.72; 95% CI, 0.69–0.74), and a propensity score adjusted logistic regression model (OR 0.72; 95% CI, 0.69–0.75). Conclusions Using a comprehensive all-payer cohort of neurosurgery patients in New York State we identified an association of African-American race and lack of insurance with lower rates of admission to Magnet hospitals. PMID:28684152
Shankaran, Seetha; Laptook, Abbot R.; McDonald, Scott A.; Hintz, Susan R; Barnes, Patrick D.; Das, Abhik; Higgins, Rosemary D.
2016-01-01
Infants with perinatal sentinel events in the Eunice Kennedy Shriver National Institute of Child Health and Human Development Neonatal Research Network Hypothermia for Encephalopathy Trial had more basal ganglia and thalamus lesions on brain magnetic resonance imaging but similar neurodevelopmental outcomes at 18 months of age than infants without perinatal sentinel events. Outcomes correlated with the neonatal magnetic resonance imaging findings. PMID:27776752
Magnetic Resonance Imaging of Stroke in the Rat
CHOPP, Michael; LI, Lian; ZHANG, Li; ZHANG, Zheng-gang; LI, Qing-jiang; JIANG, Quan
2014-01-01
Magnetic resonance imaging (MRI) is now a routine neuroimaging tool in the clinic. Throughout all phases of stroke from acute to chronic, MRI plays an important role to diagnose, evaluate and monitor the cerebral tissue undergoing stroke. This review provides a description of various MRI methods and an overview of selected MRI studies, with an embolic stroke model of rat, performed in the MRI laboratory of Department of Neurology, Henry Ford Hospital, Detroit, Michigan, US. PMID:24920874
Multiple critical endpoints in magnetized three flavor quark matter
NASA Astrophysics Data System (ADS)
Ferreira, Márcio; Costa, Pedro; Providência, Constança
2018-01-01
The magnetized phase diagram for three-flavor quark matter is studied within the Polyakov extended Nambu-Jona-Lasinio model. The order parameters are analyzed with special emphasis on the strange quark condensate. We show that the presence of an external magnetic field induces several critical endpoints (CEPs) in the strange sector, which arise due to the multiple phase transitions that the strange quark undergoes. The spinodal and binodal regions of the phase transitions are shown to increase with external magnetic field strength. The influence of strong magnetic fields on the isentropic trajectories around the several CEPs is analyzed. A focusing effect is observed on the region towards the CEPs that are related with the strange quark phase transitions. Compared to the chiral transitions, the deconfinement transition turns out to be less sensitive to the external magnetic field and the crossover nature is preserved over the whole phase diagram.
Synthesis of magnetic thermosensitive microcontainers for enzyme immobilization
NASA Astrophysics Data System (ADS)
Wang, Jianzhi; Zhao, Guanghui; Wang, Xinyu; Peng, Xiaomen; Li, Yanfeng
2015-05-01
We present a new approach for the fabrication of magnetic thermoresponsive polymer microcapsules with mobile magnetic spherical cores. The microcontainers form fried-egg-like structures with a polymer shell layer of 50 nm due to the existence of hollow cavities. The microcontainers undergo a temperature-induced volume phase transition upon changing the temperature and present an impressive magnetic response. The magnetic saturation of these smart microcontainers (42 emu/g) is high enough to meet most requirements of bioapplications. To further investigate the potential application of these smart microcontainers in biotechnology, Candida rugosa lipase was selected for the enzyme immobilization process. The immobilized lipase exhibited excellent thermal stability and reusability in comparison with the free enzyme. The adsorption/release of the lipase from the microcontainers can be controlled by the environmental temperature and magnetic force, thus, offering new potential applications such as in controlled drug delivery, bioseparation, and catalysis.
High-Temperature, High-Load-Capacity Radial Magnetic Bearing
NASA Technical Reports Server (NTRS)
Provenza, Andrew; Montague, Gerald; Kascak, Albert; Palazzolo, Alan; Jansen, Ralph; Jansen, Mark; Ebihara, Ben
2005-01-01
A radial heteropolar magnetic bearing capable of operating at a temperature as high as 1,000 F (=540 C) has been developed. This is a prototype of bearings for use in gas turbine engines operating at temperatures and speeds much higher than can be withstood by lubricated rolling-element bearings. It is possible to increase the maximum allowable operating temperatures and speeds of rolling-element bearings by use of cooling-air systems, sophisticated lubrication systems, and rotor-vibration- damping systems that are subsystems of the lubrication systems, but such systems and subsystems are troublesome. In contrast, a properly designed radial magnetic bearing can suspend a rotor without contact, and, hence, without need for lubrication or for cooling. Moreover, a magnetic bearing eliminates the need for a separate damping system, inasmuch as a damping function is typically an integral part of the design of the control system of a magnetic bearing. The present high-temperature radial heteropolar magnetic bearing has a unique combination of four features that contribute to its suitability for the intended application: 1. The wires in its electromagnet coils are covered with an insulating material that does not undergo dielectric breakdown at high temperature and is pliable enough to enable the winding of the wires to small radii. 2. The processes used in winding and potting of the coils yields a packing factor close to 0.7 . a relatively high value that helps in maximizing the magnetic fields generated by the coils for a given supplied current. These processes also make the coils structurally robust. 3. The electromagnets are of a modular C-core design that enables replacement of components and semiautomated winding of coils. 4. The stator is mounted in such a manner as to provide stable support under radial and axial thermal expansion and under a load as large as 1,000 lb (.4.4 kN).
Polyethylene Glycol-Mediated Synthesis of Cubic Iron Oxide Nanoparticles with High Heating Power
NASA Astrophysics Data System (ADS)
Iacovita, Cristian; Stiufiuc, Rares; Radu, Teodora; Florea, Adrian; Stiufiuc, Gabriela; Dutu, Alina; Mican, Sever; Tetean, Romulus; Lucaciu, Constantin M.
2015-10-01
Iron oxide magnetic nanoparticles (IOMNPs) have been successfully synthesized by means of solvothermal reduction method employing polyethylene glycol (PEG200) as a solvent. The as-synthesized IOMNPs are poly-dispersed, highly crystalline, and exhibit a cubic shape. The size of IOMNPs is strongly dependent on the reaction time and the ration between the amount of magnetic precursor and PEG200 used in the synthesis method. At low magnetic precursor/PEG200 ratio, the cubic IOMNPs coexist with polyhedral IOMNPs. The structure and morphology of the IOMNPs were thoroughly investigated by using a wide range of techniques: TEM, XRD, XPS, FTIR, and RAMAN. XPS analysis showed that the IOMNPs comprise a crystalline magnetite core bearing on the outer surface functional groups from PEG200 and acetate. The presence of physisorbed PEG200 on the IOMNP surface is faintly detected through FT-IR spectroscopy. The surface of IOMNPs undergoes oxidation into maghemite as proven by RAMAN spectroscopy and the occurrence of satellite peaks in the Fe2p XP spectra. The magnetic studies performed on powder show that the blocking temperature (TB) of IOMNPs is around 300 K displaying a coercive field in between 160 and 170 Oe. Below the TB, the field-cooled (FC) curves turn concave and describe a plateau indicating that strong magnetic dipole-dipole interactions are manifested in between IOMNPs. The specific absorption rate (SAR) values increase with decreasing nanoparticle concentrations for the IOMNPs dispersed in water. The SAR dependence on the applied magnetic field, studied up to magnetic field amplitude of 60 kA/m, presents a sigmoid shape with saturation values up to 1700 W/g. By dispersing the IOMNPs in PEG600 (liquid) and PEG1000 (solid), it was found that the SAR values decrease by 50 or 75 %, indicating that the Brownian friction within the solvent was the main contributor to the heating power of IOMNPs.
Fogel, Mark A.; Li, Christine; Nicolson, Susan C; Spray, Thomas L; Gaynor, J William; Fuller, Stephanie; Keller, Marc S.; Harris, Matthew A.; Yoganathan, Ajit P; Whitehead, Kevin K.
2015-01-01
Pulse wave velocity (PWV), a measure of arterial stiffness, is a known independent risk factor for cardiovascular events. Single ventricle patients who undergo aortic to pulmonary anastomosis (recon) have non-compliant patch material inserted into the neo-aorta, possibly increasing vessel stiffness and afterload. The purpose of this study is to determine if PWV differed in single ventricle patients who did and did not undergo aortic reconstruction (no-recon). We retrospectively reviewed cardiac magnetic resonance anatomic, cine and phase contrast evaluations in the ascending (AAo) and descending aorta (DAo) at the level of the diaphragm data from 126 single ventricle patients (8.6±8.0 years) from January 2012 to May, 2013. Significance = P<0.05. Seventy-five underwent recon and 51 did not. PWV in recon were significantly higher than in no-recon (3.9±0.9 m/s vs 3.2±1.0 m/s, P=0.008); in recon, patients > 13 years had a higher PWV than those < 7 years (4.5±0.6 vs 3.5±0.7 m/s, P=0.004). DAo distensibility was similar between both groups. There was no difference in age, body surface area or cardiac index between recon and no-recon. No correlations between various hemodynamic and ventricular function parameters with PWV were noted. In conclusion, PWV in recon is higher than in no-recon with similar DAo distensibility implicating the aortic reconstruction as a possible cause of increased afterload; older recon have stiffer aortas than younger ones possibly imposing an additional cardiovascular risk in the future. Other biomaterials may potentially moderate PWV if clinical outcome is adversely affected. PMID:25432153
Structural and Functional Studies on the Marburg Virus GP2 Fusion Loop.
Liu, Nina; Tao, Yisong; Brenowitz, Michael D; Girvin, Mark E; Lai, Jonathan R
2015-10-01
Marburg virus (MARV) and the ebolaviruses belong to the family Filoviridae (the members of which are filoviruses) that cause severe hemorrhagic fever. Infection requires fusion of the host and viral membranes, a process that occurs in the host cell endosomal compartment and is facilitated by the envelope glycoprotein fusion subunit, GP2. The N-terminal fusion loop (FL) of GP2 is a hydrophobic disulfide-bonded loop that is postulated to insert and disrupt the host endosomal membrane during fusion. Here, we describe the first structural and functional studies of a protein corresponding to the MARV GP2 FL. We found that this protein undergoes a pH-dependent conformational change, as monitored by circular dichroism and nuclear magnetic resonance. Furthermore, we report that, under low pH conditions, the MARV GP2 FL can induce content leakage from liposomes. The general aspects of this pH-dependent structure and lipid-perturbing behavior are consistent with previous reports on Ebola virus GP2 FL. However, nuclear magnetic resonance studies in lipid bicelles and mutational analysis indicate differences in structure exist between MARV and Ebola virus GP2 FL. These results provide new insight into the mechanism of MARV GP2-mediated cell entry. © The Author 2015. Published by Oxford University Press on behalf of the Infectious Diseases Society of America. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
NASA Astrophysics Data System (ADS)
Marchand, Paul J.; Bouwens, Arno; Shamaei, Vincent; Nguyen, David; Extermann, Jerome; Bolmont, Tristan; Lasser, Theo
2016-03-01
Magnetic Resonance Imaging has revolutionised our understanding of brain function through its ability to image human cerebral structures non-invasively over the entire brain. By exploiting the different magnetic properties of oxygenated and deoxygenated blood, functional MRI can indirectly map areas undergoing neural activation. Alongside the development of fMRI, powerful statistical tools have been developed in an effort to shed light on the neural pathways involved in processing of sensory and cognitive information. In spite of the major improvements made in fMRI technology, the obtained spatial resolution of hundreds of microns prevents MRI in resolving and monitoring processes occurring at the cellular level. In this regard, Optical Coherence Microscopy is an ideal instrumentation as it can image at high spatio-temporal resolution. Moreover, by measuring the mean and the width of the Doppler spectra of light scattered by moving particles, OCM allows extracting the axial and lateral velocity components of red blood cells. The ability to assess quantitatively total blood velocity, as opposed to classical axial velocity Doppler OCM, is of paramount importance in brain imaging as a large proportion of cortical vascular is oriented perpendicularly to the optical axis. We combine here quantitative blood flow imaging with extended-focus Optical Coherence Microscopy and Statistical Parametric Mapping tools to generate maps of stimuli-evoked cortical hemodynamics at the capillary level.
NASA Astrophysics Data System (ADS)
Hinatsu, Yukio; Doi, Yoshihiro
2013-02-01
Ternary rare-earth osmates Ln3OsO7 (Ln=Pr, Tb) have been prepared. They crystallize in an ortho-rhombic superstructure of cubic fluorite with space group Cmcm. Both of these compounds undergo a structural phase transition at 130 K (Ln=Pr) and 580 K (Ln=Tb). These compounds show complex magnetic behavior at low temperatures. Pr3OsO7 exhibits magnetic transitions at 8 and 73 K, and Tb3OsO7 magnetically orders at 8 and 60 K. The Os moments become one-dimensionally ordered, and when the temperature is furthermore decreased, it provokes the ordering in the Ln3+ sublattice that simultaneously becomes three-dimensionally ordered with the Os sublattice.
Physics in strong magnetic fields near neutron stars
NASA Technical Reports Server (NTRS)
Harding, Alice K.
1991-01-01
Electromagnetic phenomena occurring in the strong magnetic fields of neutron stars are currently of great interest in high-energy astrophysics. Observations of rotation rate changes and cyclotron lines in pulsars and gamma-ray bursts indicate that surface magnetic fields of neutron stars often exceed a trillion gauss. In fields this strong, where electrons behave much as if they were in bound atomic states, familiar processes undergo profound changes, and exotic processes become important. Strong magnetic fields affect the physics in several fundamental ways: energies perpendicular to the field are quantized, transverse momentum is not conserved, and electron-positron spin is important. Neutron stars therefore provide a unique laboratory for the study of physics in extremely high fields that cannot be generated on earth.
Collapse of magnetized hypermassive neutron stars in general relativity.
Duez, Matthew D; Liu, Yuk Tung; Shapiro, Stuart L; Shibata, Masaru; Stephens, Branson C
2006-01-27
Hypermassive neutron stars (HMNSs)--equilibrium configurations supported against collapse by rapid differential rotation--are possible transient remnants of binary neutron-star mergers. Using newly developed codes for magnetohydrodynamic simulations in dynamical spacetimes, we are able to track the evolution of a magnetized HMNS in full general relativity for the first time. We find that secular angular momentum transport due to magnetic braking and the magnetorotational instability results in the collapse of an HMNS to a rotating black hole, accompanied by a gravitational wave burst. The nascent black hole is surrounded by a hot, massive torus undergoing quasistationary accretion and a collimated magnetic field. This scenario suggests that HMNS collapse is a possible candidate for the central engine of short gamma-ray bursts.
CYCLIC THERMAL SIGNATURE IN A GLOBAL MHD SIMULATION OF SOLAR CONVECTION
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cossette, Jean-Francois; Charbonneau, Paul; Smolarkiewicz, Piotr K.
Global magnetohydrodynamical simulations of the solar convection zone have recently achieved cyclic large-scale axisymmetric magnetic fields undergoing polarity reversals on a decadal time scale. In this Letter, we show that these simulations also display a thermal convective luminosity that varies in-phase with the magnetic cycle, and trace this modulation to deep-seated magnetically mediated changes in convective flow patterns. Within the context of the ongoing debate on the physical origin of the observed 11 yr variations in total solar irradiance, such a signature supports the thesis according to which all, or part, of the variations on decadal time scales and longermore » could be attributed to a global modulation of the Sun's internal thermal structure by magnetic activity.« less
Dynamo efficiency controlled by hydrodynamic bistability.
Miralles, Sophie; Herault, Johann; Herault, Johann; Fauve, Stephan; Gissinger, Christophe; Pétrélis, François; Daviaud, François; Dubrulle, Bérengère; Boisson, Jean; Bourgoin, Mickaël; Verhille, Gautier; Odier, Philippe; Pinton, Jean-François; Plihon, Nicolas
2014-06-01
Hydrodynamic and magnetic behaviors in a modified experimental setup of the von Kármán sodium flow-where one disk has been replaced by a propeller-are investigated. When the rotation frequencies of the disk and the propeller are different, we show that the fully turbulent hydrodynamic flow undergoes a global bifurcation between two configurations. The bistability of these flow configurations is associated with the dynamics of the central shear layer. The bistable flows are shown to have different dynamo efficiencies; thus for a given rotation rate of the soft-iron disk, two distinct magnetic behaviors are observed depending on the flow configuration. The hydrodynamic transition controls the magnetic field behavior, and bifurcations between high and low magnetic field branches are investigated.
An fMRI Study of Episodic Memory: Retrieval of Object, Spatial, and Temporal Information
Hayes, Scott M.; Ryan, Lee; Schnyer, David M.; Nadel, Lynn
2011-01-01
Sixteen participants viewed a videotaped tour of 4 houses, highlighting a series of objects and their spatial locations. Participants were tested for memory of object, spatial, and temporal order information while undergoing functional Magnetic Resonance Imaging. Preferential activation was observed in right parahippocampal gyrus during the retrieval of spatial location information. Retrieval of contextual information (spatial location and temporal order) was associated with activation in right dorsolateral prefrontal cortex. In bilateral posterior parietal regions, greater activation was associated with processing of visual scenes, regardless of the memory judgment. These findings support current theories positing roles for frontal and medial temporal regions during episodic retrieval and suggest a specific role for the hippocampal complex in the retrieval of spatial location information PMID:15506871
Prediction of Liver Function by Using Magnetic Resonance-based Portal Venous Perfusion Imaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cao Yue, E-mail: yuecao@umich.edu; Department of Radiology, University of Michigan, Ann Arbor, Michigan; Wang Hesheng
2013-01-01
Purpose: To evaluate whether liver function can be assessed globally and spatially by using volumetric dynamic contrast-enhanced magnetic resonance imaging MRI (DCE-MRI) to potentially aid in adaptive treatment planning. Methods and Materials: Seventeen patients with intrahepatic cancer undergoing focal radiation therapy (RT) were enrolled in institution review board-approved prospective studies to obtain DCE-MRI (to measure regional perfusion) and indocyanine green (ICG) clearance rates (to measure overall liver function) prior to, during, and at 1 and 2 months after treatment. The volumetric distribution of portal venous perfusion in the whole liver was estimated for each scan. We assessed the correlation betweenmore » mean portal venous perfusion in the nontumor volume of the liver and overall liver function measured by ICG before, during, and after RT. The dose response for regional portal venous perfusion to RT was determined using a linear mixed effects model. Results: There was a significant correlation between the ICG clearance rate and mean portal venous perfusion in the functioning liver parenchyma, suggesting that portal venous perfusion could be used as a surrogate for function. Reduction in regional venous perfusion 1 month after RT was predicted by the locally accumulated biologically corrected dose at the end of RT (P<.0007). Regional portal venous perfusion measured during RT was a significant predictor for regional venous perfusion assessed 1 month after RT (P<.00001). Global hypovenous perfusion pre-RT was observed in 4 patients (3 patients with hepatocellular carcinoma and cirrhosis), 3 of whom had recovered from hypoperfusion, except in the highest dose regions, post-RT. In addition, 3 patients who had normal perfusion pre-RT had marked hypervenous perfusion or reperfusion in low-dose regions post-RT. Conclusions: This study suggests that MR-based volumetric hepatic perfusion imaging may be a biomarker for spatial distribution of liver function, which could aid in individualizing therapy, particularly for patients at risk for liver injury after RT.« less
Menzies, Lara; Ooi, Cinly; Kamath, Shri; Suckling, John; McKenna, Peter; Fletcher, Paul; Bullmore, Ed; Stephenson, Caroline
2007-02-01
Cognitive impairment causes morbidity in schizophrenia and could be due to abnormalities of cortical interneurons using the inhibitory neurotransmitter gamma-aminobutyric acid (GABA). To test the predictions that cognitive and brain functional responses to GABA-modulating drugs are correlated and abnormal in schizophrenia. Pharmacological functional magnetic resonance imaging study of 2 groups, each undergoing scanning 3 times, using an N-back working memory task, after placebo, lorazepam, or flumazenil administration. Eleven patients with chronic schizophrenia were recruited from a rehabilitation service, and 11 healthy volunteers matched for age, sex, and premorbid IQ were recruited from the local community. Intervention Participants received 2 mg of oral lorazepam, a 0.9-mg intravenous flumazenil bolus followed by a flumazenil infusion of 0.0102 mg/min, or oral and intravenous placebo. Working memory performance was summarized by the target discrimination index at several levels of difficulty. Increasing (or decreasing) brain functional activation in response to increasing task difficulty was summarized by the positive (or negative) load response. Lorazepam impaired performance and flumazenil enhanced it; these cognitive effects were more salient in schizophrenic patients. Functional magnetic resonance imaging demonstrated positive load response in a frontoparietal system and negative load response in the temporal and posterior cingulate regions; activation of the frontoparietal cortex was positively correlated with deactivation of the temporocingulate cortex. After placebo administration, schizophrenic patients had abnormally attenuated activation of the frontoparietal cortex and deactivation of the temporocingulate cortex; this pattern was mimicked in healthy volunteers and exacerbated in schizophrenic patients by lorazepam. However, in schizophrenic patients, flumazenil enhanced deactivation of the temporocingulate and activation of the anterior cingulate cortices. The GABA-modulating drugs differentially affect working memory performance and brain function in schizophrenia. Cognitive impairment in schizophrenia may reflect abnormal inhibitory function and could be treated by drugs targeting GABA neurotransmission.
NASA Astrophysics Data System (ADS)
Samatham, S. Shanmukharao; Suresh, K. G.
2017-01-01
The detailed magnetic study of complex 3d-electron based Fe3Ga4 is reported. It undergoes paramagnetic to antiferromagnetic (TN) and antiferromagnetic to ferromagnetic (TC) transitions respectively around 380 and 70 K. The thermal hysteresis of field-cooled cooling (FCC) and field-cooled warming (FCW) hints at first order phase transition below Curie temperature. A weak phase coexistence of ferro and antiferromagnetic phases is suggested by exploring the arrest-like first-order phenomenon. In the intermediate temperature range, field-driven metamagnetic transition from antiferro to ferromagnetic phase is confirmed. Further bringing the system very near to TN, field-induced transitions disappear and above TN predominant paramagnetic contribution is evident. The magnetic H-T phase diagram distinguishing different magnetic phases of Fe3Ga4 is obtained.
Reversible “triple-Q” elastic field structures in a chiral magnet
Hu, Yangfan; Wang, Biao
2016-01-01
The analytical solution of the periodic elastic fields in chiral magnets caused by presence of periodically distributed eigenstrains is obtained. For the skyrmion phase, both the periodic displacement field and the stress field are composed of three “triple-Q” structures with different wave numbers. The periodic displacement field, obtained by combining the three “triple-Q” displacement structures, is found to have the same lattice vectors with the magnetic skyrmion lattice. We find that for increasing external magnetic field, one type of “triple-Q” displacement structure and stress structure undergo a “configurational reversal”, where the initial and the final field configuration share similar pattern but with opposite direction of all the field vectors. The solution obtained is of fundamental significance for understanding the emergent mechanical properties of skyrmions in chiral magnets. PMID:27457629
Influence of SLC6A3 and COMT Variation on Neural Activation During Response Inhibition
Congdon, Eliza; Constable, R. Todd; Lesch, Klaus Peter; Canli, Turhan
2009-01-01
There is evidence concerning the neural and genetic correlates of inhibitory control, but there have been limited attempts to combine this information. This study tested the hypothesis that two dopaminergic polymorphisms, SLC6A3 and COMT, influence neural activation during response inhibition. Healthy adults were genotyped for these polymorphisms and performed a measure of response inhibition while undergoing functional magnetic resonance imaging (fMRI). Results support the role of key frontostriatal regions underlying response inhibition. Furthermore, results support a significant influence of SLC6A3 and COMT variants on neural activity during inhibition, with greater activation during inhibition in carriers of the SLC6A3 9-allele or the COMT met-allele as compared to carriers of the SLC6A3 10/10 genotype or the COMT val/val genotype. These results add to a growing literature suggesting that inhibitory control is sensitive to variation in dopamine function, and suggest that this variation may be detectable at the level of individuals’ genotypes. PMID:19482231
New MagViz Airport Liquid Analysis System Undergoes Testing
None
2017-12-09
LOS ALAMOS, New Mexico, December 16, 2008âAn innovative application of a technology first used for medical imaging may enhance airport security if Los Alamos National Laboratory scientists are successful. Los Alamos technologists have adapted Magnetic Res
MRI information for commonly used otologic implants: review and update.
Azadarmaki, Roya; Tubbs, Rhonda; Chen, Douglas A; Shellock, Frank G
2014-04-01
To review information on magnetic resonance imaging (MRI) issues for commonly used otologic implants. Manufacturing companies, National Library of Medicine's online database, and an additional online database (www.MRIsafety.com). A literature review of the National Library of Medicine's online database with focus on MRI issues for otologic implants was performed. The MRI information on implants provided by manufacturers was reviewed. Baha and Ponto Pro osseointegrated implants' abutment and fixture and the implanted magnet of the Sophono Alpha 1 and 2 abutment-free systems are approved for 3-Tesla magnetic resonance (MR) systems. The external processors of these devices are MR Unsafe. Of the implants tested, middle ear ossicular prostheses, including stapes prostheses, except for the 1987 McGee prosthesis, are MR Conditional for 1.5-Tesla (and many are approved for 3-Tesla) MR systems. Cochlear implants with removable magnets are approved for patients undergoing MRI at 1.5 Tesla after magnet removal. The MED-EL PULSAR, SONATA, CONCERT, and CONCERT PIN cochlear implants can be used in patients undergoing MRI at 1.5 Tesla with application of a protective bandage. The MED-EL COMBI 40+ can be used in 0.2-Tesla MR systems. Implants made from nonmagnetic and nonconducting materials are MR Safe. Knowledge of MRI guidelines for commonly used otologic implants is important. Guidelines on MRI issues approved by the US Food and Drug Administration are not always the same compared with other parts of the world. This monograph provides a current reference for physicians on MRI issues for commonly used otologic implants.
Ba9V3Se15: a novel compound with spin chains
NASA Astrophysics Data System (ADS)
Zhang, Jun; Liu, Min; Wang, Xiancheng; Zhao, Kan; Duan, Lei; Li, Wenmin; Zhao, Jianfa; Cao, Lipeng; Dai, Guangyang; Deng, Zheng; Feng, Shaomin; Zhang, Sijia; Liu, Qingqing; Yang, Yi-feng; Jin, Changqing
2018-05-01
In this work, a novel compound Ba9V3Se15 with one-dimensional (1D) spin chains was synthesized under high-pressure and high-temperature conditions. It was systematically characterized via structural, magnetic, thermodynamic and transport measurements. Ba9V3Se15 crystallizes into a hexagonal structure with a space group of P-6c2 (188) and the lattice constants of a = b = 9.5745(7) Å and c = 18.7814(4) Å. The crystal structure consists of face-sharing octahedral VSe6 chains along c axis, which are trimeric and arranged in a triangular lattice in ab-plane. Ba9V3Se15 is a semiconductor and undergoes complex magnetic transitions. In the zero-field-cooled (ZFC) process with magnetic field of 10 Oe, Ba9V3Se15 sequentially undergoes ferrimagnetic and spin cluster glass transition at 2.5 K and 3.3 K, respectively. When the magnetic field exceeds 50 Oe, only the ferrimagnetic transition can be observed. Above the transition temperature, the specific heat contains a significant magnetic contribution that is proportional to T 1/2. The calculation suggests that the nearest neighbor (NN) intra-chain antiferromagnetic exchange J 1 is much larger than the next nearest neighbor (NNN) intra-chain ferromagnetic exchange J 2. Therefore, Ba9V3Se15 can be regarded as an effective ferromagnetic chains with effective spin-1/2 by the formation of the V(2)(↓) V(1)(↑) V(2)(↓) cluster.
Spin reorientation and Ce-Mn coupling in antiferromagnetic oxypnictide CeMnAsO
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Qiang; Tian, Wei; Peterson, Spencer G.
2015-02-18
Structure and magnetic properties of high-quality polycrystlline CeMnAsO, a parent compound of the “1111”-type oxypnictides, have been investigated using neutron powder diffraction and magnetization measurements. We find that CeMnAsO undergoes a C-type antiferromagnetic order with Mn 2+(S = 5/2) moments pointing along the c axis below a relatively high Néel temperature of T N = 347(1) K. Below T SR = 35 K, two simultaneous transitions occur where the Mn moments reorient from the c axis to the ab plane preserving the C-type magnetic order, and Ce moments undergo long-range AFM ordering with antiparallel moments pointing in the ab plane.more » Another transition to a noncollinear magnetic structure occurs below 7 K. The ordered moments of Mn and Ce at 2 K are 3.32(4) μ B and 0.81(4)μ B, respectively. We find that CeMnAsO primarily falls into the category of a local-moment antiferromagnetic insulator in which the nearest-neighbor interaction (J 1) is dominant with J 2 < J 1/2 in the context of J 1 – J 2 – J c model. The spin reorientation transition driven by the coupling between Ce and the transition metal seems to be common to Mn, Fe, and Cr ions, but not to Co and Ni ions in the isostructural oxypnictides. As a result, a schematic illustration of magnetic structures in Mn and Ce sublattices in CeMnAsO is presented.« less
Scavarda, Valeska Tavares; Pinheiro, Aurelio Carvalho; Costa, Symône Damasceno; de Andrade, Zélia Maria; Carvalhaes, João Tomás de Abreu; Campos, Orlando; Carvalho, Antonio Carlos; Moises, Valdir Ambrosio
2014-10-01
Cardiac disease frequently occurs in children with chronic kidney disease (CKD) undergoing dialysis (DI), but it is not well studied in patients undergoing conservative treatment (CT). The aim of our study was to use echocardiography to analyze and compare the cardiac involvement of children with CKD undergoing DI or CT. Seventy-one children with CKD were included; 41 undergoing DI and 30 undergoing CT. There were 33 controls. Measurements of arterial pressure and structural and functional echocardiographic variables were obtained; the children were followed up for 18 months. Tests of comparison and multiple regression were used; significant if P < 0.05. Arterial hypertension (AH) was present in 37 of 71 (52%) children with CKD: 27 (65.8%) in DI and 10 (33.3%) in CT (X2 = 8.7; P = 0.003). An abnormal left ventricular geometric pattern was present in 37/41 (90.3%) undergoing DI, 33 had left ventricular hypertrophy (LVH), and in 14/30 (46.7%) undergoing CT, 5 had LVH. Ejection fraction was normal in all groups; diastolic function alteration (DFA) occurred in 28/41 (68.3%) children on DI and in 10/30 (33.3%) on CT (X2 = 9.2; P = 0.002). For children with CKD, DI (P = 0.002) and hypertension (P = 0.04) were associated with LVH; among those on DI, only AH was associated with LVH (P = 0.02). During the follow-up, 18 (43.9%) children undergoing DI had at least one cardiovascular event. Children with CKD undergoing CT had less cardiac involvement than those undergoing DI. LVH was associated with DI and AH in all children with CKD and with AH in those on DI.
Pressure and magnetic field effects on the valence transition of EuRh2Si2
NASA Astrophysics Data System (ADS)
Mitsuda, Akihiro; Kishaba, Eigo; Fujimoto, Takumi; Oyama, Kohei; Wada, Hirofumi; Mizumaki, Masaichiro; Kawamura, Naomi; Ishimatsu, Naoki
2018-05-01
We have measured the X-ray absorption spectra (XAS), electrical resistivity and magnetic susceptibility of EuRh2Si2, which undergoes a valence transition under high pressures. A sharp decrease in the Eu valence determined from the XAS was observed at around 70 K in the temperature dependence at P = 1.2-1.9 GPa. In the temperature dependence of electrical resistivity and magnetic susceptibility, we observed jumps associated with the temperature-induced valence transition under high pressures. The magnetoresistance detected a field-induced valence transition. The results are discussed from the thermodynamic point of view.
Spin-flop quasi-first order phase transition and putative tricritical point in Gd3Co
NASA Astrophysics Data System (ADS)
Samatham, S. Shanmukharao; Barua, Soumendu; Suresh, K. G.
2017-12-01
Magnetic nature of Gd3Co is investigated using detailed measurements of temperature and field dependent magnetization. The antiferromagnetic phase is field-instable due to prevailing ferromagnetic exchange correlations above Néel temperature TN ∼ 130K . Below TN , with gradually increasing magnetic fields, the compound undergoes a quasi-first order phase transition from AFM to spin-flop over region and eventually acquires ferromagnetic phase in higher fields. Further the point at which the quasi-first order transition ends and second order transition sets in is the tricritical point, TTCP ∼ 125.6K , HTCP ∼ 4.4kOe .
Magnetoelectric control of spin-chiral ferroelectric domains in a triangular lattice antiferromagnet
NASA Astrophysics Data System (ADS)
Kimura, Kenta; Nakamura, Hiroyuki; Ohgushi, Kenya; Kimura, Tsuyoshi
2008-10-01
We have grown single crystals of a triangular lattice antiferromagnet (TLA), CuCrO2 , and investigated the correlation between magnetic and dielectric properties. Two magnetic phase transitions are observed at TN2≈24.2K and TN1≈23.6K . It was found that ferroelectric polarization along the triangular lattice plane develops at TN1 , suggesting that the system undergoes a transition into an out-of-plane 120° spin-chiral phase at TN1 . The TLA provides an opportunity for unique magnetoelectric control of spin-chiral ferroelectric domain structures by means of electric and/or magnetic fields.
Electronic nature of the lock-in magnetic transition in Ce X Al4Si2
NASA Astrophysics Data System (ADS)
Gunasekera, J.; Harriger, L.; Dahal, A.; Maurya, A.; Heitmann, T.; Disseler, S. M.; Thamizhavel, A.; Dhar, S.; Singh, D. J.; Singh, D. K.
2016-04-01
We have investigated the underlying magnetism in newly discovered single crystal Kondo lattices Ce X Al4Si2 , where X = Rh, Ir. We show that the compound undergoes an incommensurate-to-commensurate magnetic transition at Tc=9.19 K (10.75 K in Ir). The spin correlation in the incommensurate phase is described by a spin density wave configuration of Ce ions, which locks in to the long-range antiferromagnetic order at T =Tc. The analysis of the experimental data, combined with the calculation of the electronic properties, suggests the role of the Fermi surface nesting as the primary mechanism behind this phenomenon.
CLASHING BEAM PARTICLE ACCELERATOR
Burleigh, R.J.
1961-04-11
A charged-particle accelerator of the proton synchrotron class having means for simultaneously accelerating two separate contra-rotating particle beams within a single annular magnet structure is reported. The magnet provides two concentric circular field regions of opposite magnetic polarity with one field region being of slightly less diameter than the other. The accelerator includes a deflector means straddling the two particle orbits and acting to collide the two particle beams after each has been accelerated to a desired energy. The deflector has the further property of returning particles which do not undergo collision to the regular orbits whereby the particles recirculate with the possibility of colliding upon subsequent passages through the deflector.
Stress and reward processing in bipolar disorder: a functional magnetic resonance imaging study.
Berghorst, Lisa H; Kumar, Poornima; Greve, Doug N; Deckersbach, Thilo; Ongur, Dost; Dutra, Sunny J; Pizzagalli, Diego A
2016-11-01
A link between negative life stress and the onset of mood episodes in bipolar disorder (BD) has been established, but processes underlying such a link remain unclear. Growing evidence suggests that stress can negatively affect reward processing and related neurobiological substrates, indicating that a dysregulated reward system may provide a partial explanation. The aim of this study was to test the impact of stress on reward-related neural functioning in BD. Thirteen euthymic or mildly depressed individuals with BD and 15 controls performed a Monetary Incentive Delay (MID) task while undergoing functional magnetic resonance imaging during no-stress and stress (negative psychosocial stressor involving poor performance feedback and threat of monetary deductions) conditions. In hypothesis-driven region-of-interest analyses, a significant group-by-condition interaction emerged in the amygdala during reward anticipation. Relative to controls, while anticipating a potential reward, subjects with BD were characterized by amygdalar hyperactivation in the no-stress condition but hypoactivation during stress. Moreover, relative to controls, subjects with BD had significantly larger amygdala volumes. After controlling for structural differences, the effects of stress on amygdalar function remained, whereas groups no longer differed during the no-stress condition. During reward consumption, a group-by-condition interaction emerged in the putamen due to increased putamen activation in response to rewards in participants with BD during stress, but an opposite pattern in controls. Overall, findings highlight possible impairments in using reward-predicting cues to adaptively engage in goal-directed actions in BD, combined with stress-induced hypersensitivity to reward consumption. Potential clinical implications are discussed. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Changes in Cerebral Cortex of Children Treated for Medulloblastoma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Arthur K.; Marcus, Karen J.; Department of Radiation Oncology, Dana Farber Cancer Institute, Harvard Medical School, Boston, MA
2007-07-15
Purpose: Children with medulloblastoma undergo surgery, radiotherapy, and chemotherapy. After treatment, these children have numerous structural abnormalities. Using high-resolution magnetic resonance imaging, we measured the thickness of the cerebral cortex in a group of medulloblastoma patients and a group of normally developing children. Methods and Materials: We obtained magnetic resonance imaging scans and measured the cortical thickness in 9 children after treatment of medulloblastoma. The measurements from these children were compared with the measurements from age- and gender-matched normally developing children previously scanned. For additional comparison, the pattern of thickness change was compared with the cortical thickness maps from amore » larger group of 65 normally developing children. Results: In the left hemisphere, relatively thinner cortex was found in the perirolandic region and the parieto-occipital lobe. In the right hemisphere, relatively thinner cortex was found in the parietal lobe, posterior superior temporal gyrus, and lateral temporal lobe. These regions of cortical thinning overlapped with the regions of cortex that undergo normal age-related thinning. Conclusion: The spatial distribution of cortical thinning suggested that the areas of cortex that are undergoing development are more sensitive to the effects of treatment of medulloblastoma. Such quantitative methods may improve our understanding of the biologic effects that treatment has on the cerebral development and their neuropsychological implications.« less
Magnetic structures and magnetocaloric effect in R VO4 (R =Gd , Nd )
NASA Astrophysics Data System (ADS)
Palacios, E.; Evangelisti, M.; Sáez-Puche, R.; Dos Santos-García, A. J.; Fernández-Martínez, F.; Cascales, C.; Castro, M.; Burriel, R.; Fabelo, O.; Rodríguez-Velamazán, J. A.
2018-06-01
We report the magnetic properties and magnetic structure of the zircon-type compound GdVO4, together with the magnetic structure of the isostructural NdVO4. At T ≃2.5 K, GdVO4 undergoes a phase transition to antiferromagnetic Gz, driven mainly by the exchange interactions, while the magnetic anisotropy and dipolar interactions are minor contributions. Near the liquid-helium boiling temperature, the magnetocaloric effect of GdVO4 is nearly as large as that of the structurally closely related GdPO4. It is noteworthy that GdVO4 has been recently proposed as a good passive regenerator in Gifford-McMahon cryocoolers, since adding a magnetization-demagnetization stage to the cryocooler refrigeration cycle would increase its efficiency for liquefying helium. NdVO4 is a canted Gz-type antiferromagnet and shows enhancement of the magnetic reflections in neutron diffraction below ca. 500 mK, due to the polarization of the Nd nuclei by the hyperfine field.
Anisotropic Properties of Single-Crystalline CeNiGe2
NASA Astrophysics Data System (ADS)
Jung, M. H.; Harrison, N.; Lacerda, A. H.; Pagliuso, P. G.; Sarrao, J. L.; Thompson, J. D.
2002-07-01
The anisotropic properties of CeNiGe2 with a layered crystal structure have been studied by measurements of electrical resistivity, magnetic susceptibility and magnetization. It is confirmed that CeNiGe2 undergoes two-step antiferromagnetic transition at TNI = 4 K and TNII = 3 K as reported earlier on polycrystalline samples. CeNiGe2 is found to exhibit highly anisotropic properties with an easy magnetization axis along the longest crystallographic b direction. The magnetization ratio M(H//b)/M(H⊥b) is estimated to be about 15 at 5 T. The in-plane resistivity ρ
NASA Astrophysics Data System (ADS)
Slavin, James A.; Anderson, Brian J.; Baker, Daniel N.; Benna, Mehdi; Gloeckler, George; Krimigis, Stamatios M.; McNutt, Ralph L., Jr.; Schriver, David; Solomon, Sean C.; Zurbuchen, Thomas H.
2010-05-01
During MESSENGER's third flyby of Mercury on September 29, 2009, a variable interplanetary magnetic field produced a series of several minute enhancements of the tail magnetic field by factors of ~ 2 to 3.5. The magnetic field flaring during these intervals indicates that they result from loading of the tail with magnetic flux transferred from the dayside magnetosphere. The unloading intervals were associated with plasmoids and traveling compression regions which are well known signatures of tail reconnection. The peak tail magnetic flux during the smallest loading events equaled 30% of the magnetic flux emanating from Mercury, and may have reached 100% for the largest event. In this case the dayside magnetic shielding is reduced and solar wind flux impacting the surface may be greatly enhanced. Despite the intensity of these events and their similarity to terrestrial substorm magnetic flux dynamics, no energetic charged particles with energies greater than 36 keV were observed. This absence of energetic particles constitutes a deepening puzzle for the view that the Mercury magnetosphere system is undergoing dynamical processes analogous to those at Earth during substorm events.
NASA Astrophysics Data System (ADS)
Yamada, S.; Sagayama, H.; Sugimoto, K.; Arima, T.
2018-03-01
We have succeeded in growing large high-quality single crystals of double-perovskite NdBaMn2O6 with c-axis aligned. Curie-Weiss paramagnetism and metallic conduction are observed above 290 K (TMI ). The magnetic susceptibility suddenly drops at TMI accompanied by a metal-insulator transition. Pervious studies using polycrystalline samples proposed that this material undergoes a ferromagnetic phase transition near 300K, and that the magnetic anomaly at TMI should be ascribed to layered antiferromagnetic phase transition. However, single-crystalline samples do not show any anomaly that indicates the ferromagnetic phase transition above TMI . We assign the onset of magnetic anisotropy at 235 K as antiferromagnetic transition temperature TN . Though the magnetization just above TMI shows the ferromagnetic-like magnetic-field dependence, the magnetization does not saturate under 70kOe at 300K. The magnetization behavior implies ferromagnetic fluctuation in the paramagnetic phase. The ferromagnetic fluctuation are also observed just below TMI . Because a metamagnetic transition is observed at a higher magnetic field, the ferromagnetic fluctuation competes with antiferromagnetic fluctuation in this temperature range.
Dover, Jeffrey S.; Rothaus, Kenneth
2014-01-01
Stretch marks are common skin disorders that are dermal scars with associated epidermal atrophy. They are of significant concern or psychological concern to many. This manuscript describes the use of multipolar radiofrequency with pulsed magnetic fields that was successfully used to diminish these lesions in 16 subjects undergoing a series of treatments. The improvements noted were statistically significant and no serious adverse events were noted. PMID:25276274
Lattice parameters guide superconductivity in iron-arsenides
NASA Astrophysics Data System (ADS)
Konzen, Lance M. N.; Sefat, Athena S.
2017-03-01
The discovery of superconducting materials has led to their use in technological marvels such as magnetic-field sensors in MRI machines, powerful research magnets, short transmission cables, and high-speed trains. Despite such applications, the uses of superconductors are not widespread because they function much below room-temperature, hence the costly cooling. Since the discovery of Cu- and Fe-based high-temperature superconductors (HTS), much intense effort has tried to explain and understand the superconducting phenomenon. While no exact explanations are given, several trends are reported in relation to the materials basis in magnetism and spin excitations. In fact, most HTS have antiferromagnetic undoped ‘parent’ materials that undergo a superconducting transition upon small chemical substitutions in them. As it is currently unclear which ‘dopants’ can favor superconductivity, this manuscript investigates crystal structure changes upon chemical substitutions, to find clues in lattice parameters for the superconducting occurrence. We review the chemical substitution effects on the crystal lattice of iron-arsenide-based crystals (2008 to present). We note that (a) HTS compounds have nearly tetragonal structures with a-lattice parameter close to 4 Å, and (b) superconductivity can depend strongly on the c-lattice parameter changes with chemical substitution. For example, a decrease in c-lattice parameter is required to induce ‘in-plane’ superconductivity. The review of lattice parameter trends in iron-arsenides presented here should guide synthesis of new materials and provoke theoretical input, giving clues for HTS.
Young, Michael C; Theis, Jake R; Hodges, James S; Dunn, Ty B; Pruett, Timothy L; Chinnakotla, Srinath; Walker, Sidney P; Freeman, Martin L; Trikudanathan, Guru; Arain, Mustafa; Robertson, Paul R; Wilhelm, Joshua J; Schwarzenberg, Sarah J; Bland, Barbara; Beilman, Gregory J; Bellin, Melena D
2016-08-01
Approximately two thirds of patients will remain on insulin therapy after total pancreatectomy with islet autotransplant (TPIAT) for chronic pancreatitis. We investigated the relationship between measured pancreas volume on computerized tomography or magnetic resonance imaging and features of chronic pancreatitis on imaging, with subsequent islet isolation and diabetes outcomes. Computerized tomography or magnetic resonance imaging was reviewed for pancreas volume (Vitrea software) and presence or absence of calcifications, atrophy, and dilated pancreatic duct in 97 patients undergoing TPIAT. Relationship between these features and (1) islet mass isolated and (2) diabetes status at 1-year post-TPIAT were evaluated. Pancreas volume correlated with islet mass measured as total islet equivalents (r = 0.50, P < 0.0001). Mean islet equivalents were reduced by more than half if any one of calcifications, atrophy, or ductal dilatation were observed. Pancreatic calcifications increased the odds of insulin dependence 4.0 fold (1.1, 15). Collectively, the pancreas volume and 3 imaging features strongly associated with 1-year insulin use (P = 0.07), islet graft failure (P = 0.003), hemoglobin A1c (P = 0.0004), fasting glucose (P = 0.027), and fasting C-peptide level (P = 0.008). Measures of pancreatic parenchymal destruction on imaging, including smaller pancreas volume and calcifications, associate strongly with impaired islet mass and 1-year diabetes outcomes.
Lattice parameters guide superconductivity in iron-arsenides.
Konzen, Lance M N; Sefat, Athena S
2017-03-01
The discovery of superconducting materials has led to their use in technological marvels such as magnetic-field sensors in MRI machines, powerful research magnets, short transmission cables, and high-speed trains. Despite such applications, the uses of superconductors are not widespread because they function much below room-temperature, hence the costly cooling. Since the discovery of Cu- and Fe-based high-temperature superconductors (HTS), much intense effort has tried to explain and understand the superconducting phenomenon. While no exact explanations are given, several trends are reported in relation to the materials basis in magnetism and spin excitations. In fact, most HTS have antiferromagnetic undoped 'parent' materials that undergo a superconducting transition upon small chemical substitutions in them. As it is currently unclear which 'dopants' can favor superconductivity, this manuscript investigates crystal structure changes upon chemical substitutions, to find clues in lattice parameters for the superconducting occurrence. We review the chemical substitution effects on the crystal lattice of iron-arsenide-based crystals (2008 to present). We note that (a) HTS compounds have nearly tetragonal structures with a-lattice parameter close to 4 Å, and (b) superconductivity can depend strongly on the c-lattice parameter changes with chemical substitution. For example, a decrease in c-lattice parameter is required to induce 'in-plane' superconductivity. The review of lattice parameter trends in iron-arsenides presented here should guide synthesis of new materials and provoke theoretical input, giving clues for HTS.
Formation of magnetic discontinuities through viscous relaxation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kumar, Sanjay; Bhattacharyya, R.; Smolarkiewicz, P. K.
2014-05-15
According to Parker's magnetostatic theorem, tangential discontinuities in magnetic field, or current sheets (CSs), are generally unavoidable in an equilibrium magnetofluid with infinite electrical conductivity and complex magnetic topology. These CSs are due to a failure of a magnetic field in achieving force-balance everywhere and preserving its topology while remaining in a spatially continuous state. A recent work [Kumar, Bhattacharyya, and Smolarkiewicz, Phys. Plasmas 20, 112903 (2013)] demonstrated this CS formation utilizing numerical simulations in terms of the vector magnetic field. The magnetohydrodynamic simulations presented here complement the above work by demonstrating CS formation by employing a novel approach ofmore » describing the magnetofluid evolution in terms of magnetic flux surfaces instead of the vector magnetic field. The magnetic flux surfaces being the possible sites on which CSs develop, this approach provides a direct visualization of the CS formation, helpful in understanding the governing dynamics. The simulations confirm development of tangential discontinuities through a favorable contortion of magnetic flux surfaces, as the magnetofluid undergoes a topology-preserving viscous relaxation from an initial non-equilibrium state with twisted magnetic field. A crucial finding of this work is in its demonstration of CS formation at spatial locations away from the magnetic nulls.« less
NASA Astrophysics Data System (ADS)
Goveas, Lora Rita; Anuradha, K. N.; Bhagyashree, K. S.; Bhat, S. V.
2015-05-01
To explore the effect of size reduction to nanoscale on the hole doped Sm0.65Ca0.35MnO3 compound, dc magnetic measurements and electron magnetic resonance (EMR) were done on bulk and nanoparticle samples in the temperature range 10 ≤ T ≤ 300 K. Magnetization measurement showed that the bulk sample undergoes a charge ordering transition at 240 K and shows a mixed magnetic phase at low temperature. However, the nanosample underwent a ferromagnetic transition at 75 K, and the charge ordered state was destabilized on size reduction down to nanoscale. The low-temperature ferromagnetic component is found to be enhanced in nanoparticles as compared to their bulk counterpart. Interestingly around room temperature, bulk particles show higher magnetization where as at low temperature nanoparticles show higher magnetization. Ferromagnetism in the bulk is due to super exchange where as ferromagnetism in nanoparticles is due to uncompensated spins of the surface layer. Temperature variation of EMR parameters correlates well with the results of magnetic measurements. The magnetic behaviour of the nanoparticles is understood in terms of the core shell scenario.
NASA Astrophysics Data System (ADS)
Garshelis, I. J.
1997-04-01
Conventional means of sensing position and speed of moving machine members for control purposes typically requires the use of supplementary, ad hoc devices. Many mechanically functional moving machine members are fabricated from ferromagnetic steels and may, thus, provide an opportunity to themselves carry positionally relevant information in the form of local regions of deliberately instilled remanent magnetization, Mr. To avoid ambiguities associated with the imprecise borders of such regions as well as their possibly preexisting presence, information is more reliably carried in the form of local transitions in the polarity of Mr from a quiescent bias. The presence and physical location of such transitions relative to reference features either on the member itself or on other members undergoing correlated motion constitutes stored information. The presence of a transition is signaled by the transitory appearance of the external field associated with ∇ṡMr as the transition containing region passes by a magnetic-field detecting device fixed to the machine frame. Implanting and removing transitions from parts while in motion is readily accomplished by pulsed currents and biasing magnets. While the whole process of storing, reading, and erasing bits of information in magnetic form follows the concepts and principles of conventional magnetic recording, profoundly different quantitative factors, conditions, and performance requirements affect the implementation of the described sensing system. In particular, the coercivity, Hc, of commonly used steels is 3-30 Oe versus 300-1200 Oe in recording media and both the thickness of the media and the air gaps separating the media surface from the heads used in conventional systems are each 2-3 orders of magnitude smaller than their counterparts in the described system, where speed may also be variable down to zero. While the combined effect of these factors is to greatly diminish the attainable density of recorded information, this has only modest impact on the ability of the system to fulfill its purpose by effectively providing a dynamically adjustable "magnetic cam." The magnetic and operational details of an experimental sensing system were explored using a "timing" belt as the mechanically functional member. The molded polyurethane belt incorporated cabled steel wires (nine cold drawn carbon steel 0.08 mm diam) wound in an 0.8 mm pitch helix around the belt circumference; 13 full turns in the 10 mm wide belt. An isolated cable showed 4πM=15 kG in a 100 Oe field, 4πMr=11.9 kG with Hc=17 Oe. The belt was driven at surface speeds from 0-10 m/s. Bias was provided by a small barium ferrite magnet, magnetic transitions were recorded by current pulses through a coil wound on a gapped core and detected by a Hall-effect field sensor located at a fixed distance downstream. Fields of ±10 Oe with gradients >1 Oe/mm were detected at distances of 1.5 mm from the belt surface. Speed was determined from the elapsed time between a recording pulse and its detection.
Teasdale, G. M.; Hadley, D. M.; Lawrence, A.; Bone, I.; Burton, H.; Grant, R.; Condon, B.; Macpherson, P.; Rowan, J.
1989-01-01
OBJECTIVE--To compare computed tomography and magnetic resonance imaging in investigating patients suspected of having a lesion in the posterior cranial fossa. DESIGN--Randomised allocation of newly referred patients to undergo either computed tomography or magnetic resonance imaging; the alternative investigation was performed subsequently only in response to a request from the referring doctor. SETTING--A regional neuroscience centre serving 2.7 million. PATIENTS--1020 Patients recruited between April 1986 and December 1987, all suspected by neurologists, neurosurgeons, or other specialists of having a lesion in the posterior fossa and referred for neuroradiology. The groups allocated to undergo computed tomography or magnetic resonance imaging were well matched in distributions of age, sex, specialty of referring doctor, investigation as an inpatient or an outpatient, suspected site of lesion, and presumed disease process; the referring doctor's confidence in the initial clinical diagnosis was also similar. INTERVENTIONS--After the patients had been imaged by either computed tomography or magnetic resonance (using a resistive magnet of 0.15 T) doctors were given the radiologist's report and a form asking if they considered that imaging with the alternative technique was necessary and, if so, why; it also asked for their current diagnoses and their confidence in them. MAIN OUTCOME MEASURES--Number of requests for the alternative method of investigation. Assessment of characteristics of patients for whom further imaging was requested and lesions that were suspected initially and how the results of the second imaging affected clinicians' and radiologists' opinions. RESULTS--Ninety three of the 501 patients who initially underwent computed tomography were referred subsequently for magnetic resonance imaging whereas only 28 of the 493 patients who initially underwent magnetic resonance imaging were referred subsequently for computed tomography. Over the study the number of patients referred for magnetic resonance imaging after computed tomography increased but requests for computed tomography after magnetic resonance imaging decreased. The reason that clinicians gave most commonly for requesting further imaging by magnetic resonance was that the results of the initial computed tomography failed to exclude their suspected diagnosis (64 patients). This was less common in patients investigated initially by magnetic resonance imaging (eight patients). Management of 28 patients (6%) imaged initially with computed tomography and 12 patients (2%) imaged initially with magnetic resonance was changed on the basis of the results of the alternative imaging. CONCLUSIONS--Magnetic resonance imaging provided doctors with the information required to manage patients suspected of having a lesion in the posterior fossa more commonly than computed tomography, but computed tomography alone was satisfactory in 80% of cases... PMID:2506965
Aben, Hugo P; Reijmer, Yael D; Visser-Meily, Johanna Ma; Spikman, Jacoba M; de Bresser, Jeroen; Biessels, Geert Jan; de Kort, Paul Lm
2018-05-28
Cognitive impairment is common after acute ischemic stroke, affecting up to 75% of the patients. About half of the patients will show recovery, whereas the others will remain cognitively impaired or deteriorate. It is difficult to predict these different cognitive outcomes. The objective of this study is to investigate whether diffusion tensor imaging-based measures of brain connectivity predict cognitive recovery after 1 year, in addition to patient characteristics and stroke severity. A specific premise of the Prediction of Cognitive Recovery After Stroke (PROCRAS) study is that it is conducted in a daily practice setting. The PROCRAS study is a prospective, mono-center cohort study conducted in a large teaching hospital in the Netherlands. A total of 350 patients suffering from an ischemic stroke who screen positive for cognitive impairment on the Montreal Cognitive Assessment (MoCA<26) in the acute stage will undergo a 3Tesla-Magnetic Resonance Imaging (3T-MRI) with a diffusion-weighted sequence and a neuropsychological assessment. Patients will be classified as being unimpaired, as having a mild vascular cognitive disorder, or as having a major vascular cognitive disorder. One year after stroke, patients will undergo follow-up neuropsychological assessment. The primary endpoint is recovery of cognitive function 1 year after stroke in patients with a confirmed poststroke cognitive disorder. The secondary endpoint is deterioration of cognitive function in the first year after stroke. The study is already ongoing for 1.5 years, and thus far, 252 patients have provided written informed consent. Final results are expected in June 2019. The PROCRAS study will show the additional predictive value of diffusion tensor imaging-based measures of brain connectivity for cognitive outcome at 1 year in patients with a poststroke cognitive disorder in a daily clinical practice setting. RR1-10.2196/9431. ©Hugo P Aben, Yael D Reijmer, Johanna MA Visser-Meily, Jacoba M Spikman, Jeroen de Bresser, Geert Jan Biessels, Paul LM de Kort. Originally published in JMIR Research Protocols (http://www.researchprotocols.org), 28.05.2018.
Strain-driven electric control of magnetization reversal at multiferroic interfaces
NASA Astrophysics Data System (ADS)
Odkhuu, Dorj; Kioussis, Nicholas
2018-03-01
We predict that biaxial strain of several percent has a colossal effect on the magnetic anisotropy of ultrathin Fe /X TiO3 (X =Sr ,Ba ) bilayers grown epitaxially on appropriate substrates. We demonstrate that under large compressive biaxial strain the Fe film undergoes an in-plane to out-of-plane spin reorientation via ferroelectric polarization switching, where the critical strain depends on the Fe film thickness. The underlying mechanism is the interplay between the strain-enhanced magnetoelectric coupling associated with the enhanced polarization in the ferroelectric substrate and the strain-reduced magnetic anisotropy energy of the Fe overlayer. These findings open interesting prospects for exploiting stain engineering to harvest higher electric field efficiency of magnetic anisotropy for the next generation of magnetoelectric random access memory devices.
Suppression of magnetostructural transition on GdSiGe thin film after thermal cyclings
Pires, A. L.; Belo, J. H.; Gomes, I. T.; ...
2016-09-08
The influence of thermal cycling on the microstructure, magnetic phase transition and magnetic entropy change of a Gd 5Si 1.3Ge 2.7 thin film up to 1000 cycles is investigated. The authors found that after 1000 cycles a strong reduction of the crystallographic phase responsible for the magnetostructural transition (Orthorhombic II phase) occurs. We attribute this to the chemical disorder, caused by the large number of expansion/compression cycles that the Orthorhombic II phase undergoes across the magnetostructural transition. The suppression of the magnetostructural transition corresponds to a drastic decrease of the thin film magnetic entropy change. Our results reveal the importancemore » of studying the thermal/magnetic cycles influence on magnetostructural transitions as they can damage a real-life device.« less
Magnetomechanical effect in silicon (Cz-Si) surface layers
NASA Astrophysics Data System (ADS)
Koplak, O. V.; Dmitriev, A. I.; Morgunov, R. B.
2012-07-01
The mechanical properties of near-surface layers of Czochralski-grown silicon crystals Cz- n-Si(111) have been found to undergo changes in response to an external constant magnetic field ( B ˜ 0.1 T). A magnetically induced variation in the microhardness, Young's modulus, and coefficient of plasticity of silicon crystals correlates with the change in the lattice parameter and internal stresses of the sample. The growth of an oxide film under exposure to a magnetic field plays the principal role in the magnetomechanical effect due to a decrease in the concentration of oxygen complexes in the near-surface layers of the sample. In microstructured silicon, where the surface is considerably more developed, the magnetic field induces more profound changes in the internal stresses as compared to single crystals.
Neural Correlates of Response Inhibition and Cigarette Smoking in Late Adolescence
Galván, Adriana; Poldrack, Russell A; Baker, Christine M; McGlennen, Kristine M; London, Edythe D
2011-01-01
Smoking is usually initiated in adolescence, and is the leading preventable cause of death in the United States. Little is known, however, about the links between smoking and neurobiological function in adolescent smokers. This study aimed to probe prefrontal cortical function in late adolescent smokers, using a response inhibition task, and to assess possible relationships between inhibition-related brain activity, clinical features of smoking behavior, and exposure to cigarette smoking. Participants in this study were otherwise healthy late adolescent smokers (15–21 years of age; n=25), who reported daily smoking for at least the 6 months before testing, and age- and education-matched nonsmokers (16–21 years of age; n=25), who each reported smoking fewer than five cigarettes in their lifetimes. The subjects performed the Stop-signal Task, while undergoing functional magnetic resonance imaging. There were no significant group differences in prefrontal cortical activity during response inhibition, but the Heaviness of Smoking Index, a measure of smoking behavior and dependence, was negatively related to neural function in cortical regions of the smokers. These findings suggest that smoking can modulate prefrontal cortical function. Given the late development of the prefrontal cortex, which continues through adolescence, it is possible that smoking may influence the trajectory of brain development during this critical developmental period. PMID:21270772
A Posteriori Comparison of Natural and Surgical Destabilization Models of Canine Osteoarthritis
Pelletier, Jean-Pierre; d'Anjou, Marc-André; Blond, Laurent; Pelletier, Johanne-Martel; del Castillo, Jérôme R. E.
2013-01-01
For many years Canis familiaris, the domestic dog, has drawn particular interest as a model of osteoarthritis (OA). Here, we optimized the dog model of experimental OA induced by cranial cruciate ligament sectioning. The usefulness of noninvasive complementary outcome measures, such as gait analysis for the limb function and magnetic resonance imaging for structural changes, was demonstrated in this model. Relationships were established between the functional impairment and the severity of structural changes including the measurement of cartilage thinning. In the dog model of naturally occurring OA, excellent test-retest reliability was denoted for the measurement of the limb function. A criterion to identify clinically meaningful responders to therapy was determined for privately owned dogs undergoing clinical trials. In addition, the recording of accelerometer-based duration of locomotor activity showed strong and complementary agreement with the biomechanical limb function. The translation potential of these models to the human OA condition is underlined. A preclinical testing protocol which combines the dog model of experimental OA induced by cranial cruciate ligament transection and the Dog model of naturally occurring OA offers the opportunity to further investigate the structural and functional benefits of disease-modifying strategies. Ultimately, a better prediction of outcomes for human clinical trials would be brought. PMID:24288664
Exchange bias in multiferroic Ca3Mn2O7 effected by Dzyaloshinskii-Moriya interaction
NASA Astrophysics Data System (ADS)
Sahlot, Pooja; Jana, Anupam; Awasthi, A. M.
2018-04-01
Ruddlesden-Popper manganite Ca3Mn2O7 has been synthesized in single phase orthorhombic structure with Cmcm space group. Temperature dependent magnetization M(T) shows that Ca3Mn2O7 undergoes long range antiferromagnetic (AFM) transition below 123 K, with weak ferromagnetism (WFM) at lower temperatures. Field dependent magnetization M(H) confirms WFM character below ˜110 K in the AFM-base magnetic structure. Detailed analysis of the zero field cooled magnetic hysteresis loops reveals a measurable exchange bias (EB) effect in the sample. EB is attributed to the high anisotropy in the sample and the presence of Dzyaloshinskii-Moriya (D-M) interaction, responsible for the canted interfacial-spins that couple "FM-clusters" with the "AFM-matrix". Temperature dependence of horizontal shifts of the M(H) loops in terms of the coercive fields (Hc±) and vertical shifts in terms of the remnant magnetizations (Mr±) is presented.
Wulferding, Dirk; Yang, Ilkyu; Yang, Jinho; ...
2015-07-31
We present a local probe study of the magnetic superconductor ErNi 2B 2C, using magnetic force microscopy at sub-Kelvin temperatures. ErNi 2B 2C is an ideal system to explore the effects of concomitant superconductivity and ferromagnetism. At 500 mK, far below the transition to a weakly ferromagnetic state, we directly observe a structured magnetic background on the micrometer scale. We determine spatially resolved absolute values of the magnetic penetration depth λ and study its temperature dependence as the system undergoes magnetic phase transitions from paramagnetic to antiferromagnetic, and to weak ferromagnetic, all within the superconducting regime. We estimate the absolutemore » pinning force of Abrikosov vortices, which shows a position dependence and temperature dependence as well, and discuss the possibility of the purported spontaneous vortex formation.« less
Positioning of nasobiliary tube using magnet-loaded catheters.
Watanabe, Seitaro; Sato, Takamitsu; Kato, Shingo; Hosono, Kunihiro; Kobayashi, Noritoshi; Nakajima, Atsushi; Kubota, Kensuke
2013-10-01
In endoscopic nasobiliary drainage (ENBD), repositioning the catheter from the mouth to the nose is complicated. We devised a method using catheters with magnets and verified its utility and safety. We prospectively enrolled 20 patients undergoing ENBD at Yokohama City University Hospital. The procedures were successful in all 20 cases and no case required a change of operators to a senior doctor. The mean time for the procedure was 36.6 seconds. The emetic reflex was induced 0.5 times on average using the magnet method. The mean X-ray exposure time was 29.6 seconds. No complications occurred. The magnet-loaded catheter method for positioning the ENBD catheter before finally leading it through the nose took little time and was performed successfully and safely. Therefore, the magnet method could become the first choice among techniques for ENBD catheter placement. © Georg Thieme Verlag KG Stuttgart · New York.
Higgs transition from a magnetic Coulomb liquid to a ferromagnet in Yb2Ti2O7
Chang, Lieh-Jeng; Onoda, Shigeki; Su, Yixi; Kao, Ying-Jer; Tsuei, Ku-Ding; Yasui, Yukio; Kakurai, Kazuhisa; Lees, Martin Richard
2012-01-01
In a class of frustrated magnets known as spin ice, magnetic monopoles emerge as classical defects and interact via the magnetic Coulomb law. With quantum-mechanical interactions, these magnetic charges are carried by fractionalized bosonic quasi-particles, spinons, which can undergo Bose–Einstein condensation through a first-order transition via the Higgs mechanism. Here, we report evidence of a Higgs transition from a magnetic Coulomb liquid to a ferromagnet in single-crystal Yb2Ti2O7. Polarized neutron scattering experiments show that the diffuse [111]-rod scattering and pinch-point features, which develop on cooling are suddenly suppressed below TC~0.21 K, where magnetic Bragg peaks and a full depolarization of the neutron spins are observed with thermal hysteresis, indicating a first-order ferromagnetic transition. Our results are explained on the basis of a quantum spin-ice model, whose high-temperature phase is effectively described as a magnetic Coulomb liquid, whereas the ground state shows a nearly collinear ferromagnetism with gapped spin excitations. PMID:22871811
Focused tight dressing does not prevent cochlear implant magnet migration under 1.5 Tesla MRI.
Cuda, D; Murri, A; Succo, G
2013-04-01
We report a retrospective case of inner magnet migration, which occurred after 1.5 Tesla MRI scanning in an adult recipient of a bilateral cochlear implant (CI) despite a focused head dressing. The patient, bilaterally implanted with Nucleus 5 CIs (Cochlear LTD, Sydney, Australia), underwent a 1.5 Tesla cholangio-MRI scan for biliary duct pathology. In subsequent days, a focal skin alteration appeared over the left inner coil. Plain skull radiographs showed partial magnet migration on the left side. Surgical exploration confirmed magnet twisting; the magnet was effectively repositioned. Left CI performance was restored to pre-migration level. The wound healed without complications. Thus, focused dressing does not prevent magnet migration in CI recipients undergoing 1.5 Tesla MRI. All patients should be counselled on this potential complication. A minor surgical procedure is required to reposition the magnet. Nevertheless, timely diagnosis is necessary to prevent skin breakdown and subsequent device contamination. Plain skull radiograph is very effective in identifying magnet twisting; it should be performed systematically after MRI or minimally on all suspected cases.
NASA Astrophysics Data System (ADS)
Madiligama, A. S. B.; Ari-Gur, P.; Ren, Y.; Koledov, V. V.; Dilmieva, E. T.; Kamantsev, A. P.; Mashirov, A. V.; Shavrov, V. G.; Gonzalez-Legarreta, L.; Grande, B. H.
2017-11-01
Ni-Mn-In-Co Heusler alloys demonstrate promising magnetocaloric performance for use as refrigerants in magnetic cooling systems with the goal of replacing the lower efficiency, eco-adverse fluid-compression technology. The largest change in entropy occurs when the applied magnetic field causes a merged structural and magnetic transformation and the associated entropy changes of the two transformations works constructively. In this study, magnetic and crystalline phase transformations were each treated separately and the effects of the application of magnetic field on thermal hystereses associated with both structural and magnetic transformations of the Ni52Mn25In16Co7 were studied. From the analysis of synchrotron diffraction data and thermomagnetic measurements, it was revealed that the alloy undergoes both structural (from cubic austenite to a mixture of 7M &5M modulated martensite) and magnetic (ferromagnetic to a low-magnetization phase) phase transformations. Thermal hysteresis is associated with both transformations, and the variation of the thermal hystereses of the magnetic and structural transformations with applied magnetic field is significantly different. Because of the differences between the hystereses loops of the two transformations, they merge only upon heating under a certain magnetic field.
Patterns of gene expression in a scleractinian coral undergoing natural bleaching.
Seneca, Francois O; Forêt, Sylvain; Ball, Eldon E; Smith-Keune, Carolyn; Miller, David J; van Oppen, Madeleine J H
2010-10-01
Coral bleaching is a major threat to coral reefs worldwide and is predicted to intensify with increasing global temperature. This study represents the first investigation of gene expression in an Indo-Pacific coral species undergoing natural bleaching which involved the loss of algal symbionts. Quantitative real-time polymerase chain reaction experiments were conducted to select and evaluate coral internal control genes (ICGs), and to investigate selected coral genes of interest (GOIs) for changes in gene expression in nine colonies of the scleractinian coral Acropora millepora undergoing bleaching at Magnetic Island, Great Barrier Reef, Australia. Among the six ICGs tested, glyceraldehyde 3-phosphate dehydrogenase and the ribosomal protein genes S7 and L9 exhibited the most constant expression levels between samples from healthy-looking colonies and samples from the same colonies when severely bleached a year later. These ICGs were therefore utilised for normalisation of expression data for seven selected GOIs. Of the seven GOIs, homologues of catalase, C-type lectin and chromoprotein genes were significantly up-regulated as a result of bleaching by factors of 1.81, 1.46 and 1.61 (linear mixed models analysis of variance, P < 0.05), respectively. We present these genes as potential coral bleaching response genes. In contrast, three genes, including one putative ICG, showed highly variable levels of expression between coral colonies. Potential variation in microhabitat, gene function unrelated to the stress response and individualised stress responses may influence such differences between colonies and need to be better understood when designing and interpreting future studies of gene expression in natural coral populations.
Coexistence of long-range cycloidal order and spin-cluster glass state in the multiferroic BaYFeO4.
Ghara, Somnath; Sundaresan, A
2018-06-20
We report the presence of spin glass state below the cycloidal spin ordering in the multiferroic BaYFeO 4 . This compound is known to crystallize in an orthorhombic structure with a centrosymmetric space group Pnma and exhibits two successive antiferromagnetic phase transitions. Upon cooling, it undergoes a spin density wave (SDW)-like antiferromagnetic ordering at T N1 ~ 48 K and a cycloidal ordering at T N2 ~ 35 K. Using dc magnetic memory effect and magnetization relaxation studies, we have shown that this oxide undergoes a reentrant spin glass transition below T * ~ 17 K. Our analysis suggests the presence of spin clusters in the glassy state. The coexistence of spin-cluster glass and long-range cycloidal ordered states results in an exchange bias effect at 2 K. The origin of the glassy state has been attributed to freezing of some Fe 3+ moments, which do not participate in the long-range ordering.
Coexistence of long-range cycloidal order and spin-cluster glass state in the multiferroic BaYFeO4
NASA Astrophysics Data System (ADS)
Ghara, Somnath; Sundaresan, A.
2018-06-01
We report the presence of spin glass state below the cycloidal spin ordering in the multiferroic BaYFeO4. This compound is known to crystallize in an orthorhombic structure with a centrosymmetric space group Pnma and exhibits two successive antiferromagnetic phase transitions. Upon cooling, it undergoes a spin density wave (SDW)-like antiferromagnetic ordering at T N1 ~ 48 K and a cycloidal ordering at T N2 ~ 35 K. Using dc magnetic memory effect and magnetization relaxation studies, we have shown that this oxide undergoes a reentrant spin glass transition below T * ~ 17 K. Our analysis suggests the presence of spin clusters in the glassy state. The coexistence of spin-cluster glass and long-range cycloidal ordered states results in an exchange bias effect at 2 K. The origin of the glassy state has been attributed to freezing of some Fe3+ moments, which do not participate in the long-range ordering.
NASA Astrophysics Data System (ADS)
Tabata, Chihiro; Miura, Naoyuki; Uhlířová, Klára; Vališka, Michal; Saito, Hiraku; Hidaka, Hiroyuki; Yanagisawa, Tatsuya; Sechovský, Vladimír; Amitsuka, Hiroshi
2016-12-01
Single-crystalline UAu2Si2 has been grown by a floating-zone melting method, and its magnetic, thermal, and transport properties have been investigated through measurements of magnetization, specific heat, and electrical resistivity to reveal its peculiar magnetism. It is shown that UAu2Si2 undergoes a second-order phase transition at Tm = 19 K, which had been believed to be ferromagnetic ordering in the literature, from a paramagnetic phase to an uncompensated antiferromagnetic phase with spontaneous magnetization along the tetragonal c axis (the easy magnetization direction). The magnetic entropy analysis points to the itinerant character of 5 f electrons in the magnetic ordered state of UAu2Si2 with large enhancement of the electronic specific heat coefficient of γ ˜150 mJ/K2mol at 2 K. It also reveals the relatively isotropic crystalline electric field effect of this compound, with contrast to the other relative isostructural compounds. The observed magnetization curves strongly suggest that there is a parasitic ferromagnetic component developing below ˜50 K in high coercivity with the easy axis along the tetragonal c axis. The results are discussed in the context of evolution of magnetism within the entire family of isostructural U T2Si2 compounds.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miloshevich, George; Lingam, Manasvi; Morrison, Philip J.
Recent progress regarding the noncanonical Hamiltonian formulation of extended magnetohydrodynamics (XMHD), a model with Hall drift and electron inertia, is summarized. The advantages of the Hamiltonian approach are invoked to study some general properties of XMHD turbulence, and to compare them against their ideal MHD counterparts. For instance, the helicity flux transfer rates for XMHD are computed, and Liouville's theorem for this model is also verified. The latter is used, in conjunction with the absolute equilibrium states, to arrive at the spectra for the invariants, and to determine the direction of the cascades, e.g., generalizations of the well-known ideal MHDmore » inverse cascade of magnetic helicity. After a similar analysis is conducted for XMHD by inspecting second order structure functions and absolute equilibrium states, a couple of interesting results emerge. When cross helicity is taken to be ignorable, the inverse cascade of injected magnetic helicity also occurs in the Hall MHD range-this is shown to be consistent with previous results in the literature. In contrast, in the inertial MHD range, viz at scales smaller than the electron skin depth, all spectral quantities are expected to undergo direct cascading. Finally, the consequences and relevance of our results in space and astrophysical plasmas are also briefly discussed.« less
NASA Astrophysics Data System (ADS)
Zhao, K.; Glasbrenner, J. K.; Gretarsson, H.; Schmitz, D.; Bednarcik, J.; Etter, M.; Sun, J. P.; Manna, R. S.; Al-Zein, A.; Lafuerza, S.; Scherer, W.; Cheng, J. G.; Gegenwart, P.
2018-02-01
A well-known feature of the CaFe2As2 -based superconductors is the pressure-induced collapsed tetragonal phase that is commonly ascribed to the formation of an interlayer As-As bond. Using detailed x-ray scattering and spectroscopy, we find that Rh-doped Ca0.8Sr0.2Fe2As2 does not undergo a first-order phase transition and that local Fe moments persist despite the formation of interlayer As-As bonds. Our density functional theory calculations reveal that the Fe-As bond geometry is critical for stabilizing magnetism and the pressure-induced drop in the c lattice parameter observed in pure CaFe2As2 is mostly due to a constriction within the FeAs planes. The collapsed tetragonal phase emerges when covalent bonding of strongly hybridized Fe 3 d and As 4 p states completely wins out over their exchange splitting. Thus the collapsed tetragonal phase is properly understood as a strong covalent phase that is fully nonmagnetic with the As-As bond forming as a by-product.
Three-dimensional control of crystal growth using magnetic fields
NASA Astrophysics Data System (ADS)
Dulikravich, George S.; Ahuja, Vineet; Lee, Seungsoo
1993-07-01
Two coupled systems of partial differential equations governing three-dimensional laminar viscous flow undergoing solidification or melting under the influence of arbitrarily oriented externally applied magnetic fields have been formulated. The model accounts for arbitrary temperature dependence of physical properties including latent heat release, effects of Joule heating, magnetic field forces, and mushy region existence. On the basis of this model a numerical algorithm has been developed and implemented using central differencing on a curvilinear boundary-conforming grid and Runge-Kutta explicit time-stepping. The numerical results clearly demonstrate possibilities for active and practically instantaneous control of melt/solid interface shape, the solidification/melting front propagation speed, and the amount and location of solid accrued.
Gapless Spin Excitations in the Field-Induced Quantum Spin Liquid Phase of α -RuCl3
NASA Astrophysics Data System (ADS)
Zheng, Jiacheng; Ran, Kejing; Li, Tianrun; Wang, Jinghui; Wang, Pengshuai; Liu, Bin; Liu, Zheng-Xin; Normand, B.; Wen, Jinsheng; Yu, Weiqiang
2017-12-01
α -RuCl3 is a leading candidate material for the observation of physics related to the Kitaev quantum spin liquid (QSL). By combined susceptibility, specific-heat, and nuclear-magnetic-resonance measurements, we demonstrate that α -RuCl3 undergoes a quantum phase transition to a QSL in a magnetic field of 7.5 T applied in the a b plane. We show further that this high-field QSL phase has gapless spin excitations over a field range up to 16 T. This highly unconventional result, unknown in either Heisenberg or Kitaev magnets, offers insight essential to establishing the physics of α -RuCl3 .
Magnetic and electrical control of engineered materials
Schuller, Ivan K.; de La Venta Granda, Jose; Wang, Siming; Ramirez, Gabriel; Erekhinskiy, Mikhail; Sharoni, Amos
2016-08-16
Methods, systems, and devices are disclosed for controlling the magnetic and electrical properties of materials. In one aspect, a multi-layer structure includes a first layer comprising a ferromagnetic or ferrimagnetic material, and a second layer positioned within the multi-layer structure such that a first surface of the first layer is in direct physical contact with a second surface of the second layer. The second layer includes a material that undergoes structural phase transitions and metal-insulator transitions upon experiencing a change in temperature. One or both of the first and second layers are structured to allow a structural phase change associated with the second layer cause a change magnetic properties of the first layer.
Magnetic Phase Transitions in NdCoAsO
DOE Office of Scientific and Technical Information (OSTI.GOV)
McGuire, Michael A; Gout, Delphine J; Garlea, Vasile O
2010-01-01
NdCoAsO undergoes three magnetic phase transitions below room temperature. Here we report the results of our experimental investigation of this compound, including determination of the crystal and magnetic structures using powder neutron diffraction, as well as measurements of electrical resistivity, thermal conductivity, Seebeck coefficient, magnetization, and heat capacity. These results show that upon cooling a ferromagnetic state emerges near 69 K with a small saturation moment of -0.2{micro}{sub B}, likely on Co atoms. At 14 K the material enters an antiferromagnetic state with propagation vector (0 0 1/2) and small ordered moments (-0.4{micro}{sub B}) on Co and Nd. Near 3.5more » K a third transition is observed, and corresponds to the antiferromagnetic ordering of larger moments on Nd, with the same propagation vector. The ordered moment on Nd reaches 1.39(5){micro}{sub B} at 300 mK. Anomalies in the magnetization, electrical resistivity, and heat capacity are observed at all three magnetic phase transitions.« less
Local Matrix-Cluster Interactions In La1-x SrxCoO3.
NASA Astrophysics Data System (ADS)
Giblin, Sean; Terry, Ian; Boothroyd, Andrew; Prabhakaran, Dharmalingiam; Wu, Jing; Leighton, Chris
2006-03-01
Magneto-electronic phase separation plays an integral part in many recent advances in the understanding of correlated electron systems. We have studied the magnetically phase separated material La1-x SrxCoO3 and the parent compound LaCoO3, using muon spectroscopy and magnetic susceptibility measurements. The muon as a local magnetic probe is sensitive to the magnetic field distribution in LaCoO3 in the LS state, which is a direct consequence of magnetic excitons. We believe that these excitons are interacting with the Co ions undergoing the known thermally induced spin transition. By directly comparing the results of the parent compound with La1-x SrxCoO3 we can observe the hole-rich ferromagnetic clusters interacting with the neighboring hole poor matrix for low x. This mechanism, detected here for the first time, may play an important role in the rich electrical and magnetic properties of La1-x SrxCoO3.
The Buildup of a Scale-free Photospheric Magnetic Network
NASA Astrophysics Data System (ADS)
Thibault, K.; Charbonneau, P.; Crouch, A. D.
2012-10-01
We use a global Monte Carlo simulation of the formation of the solar photospheric magnetic network to investigate the origin of the scale invariance characterizing magnetic flux concentrations visible on high-resolution magnetograms. The simulations include spatially and temporally homogeneous injection of small-scale magnetic elements over the whole photosphere, as well as localized episodic injection associated with the emergence and decay of active regions. Network elements form in response to cumulative pairwise aggregation or cancellation of magnetic elements, undergoing a random walk on the sphere and advected on large spatial scales by differential rotation and a poleward meridional flow. The resulting size distribution of simulated network elements is in very good agreement with observational inferences. We find that the fractal index and size distribution of network elements are determined primarily by these post-emergence surface mechanisms, and carry little or no memory of the scales at which magnetic flux is injected in the simulation. Implications for models of dynamo action in the Sun are briefly discussed.
NASA Astrophysics Data System (ADS)
Jiang, Zhaoxia; Rochette, Pierre; Liu, Qingsong; Gattacceca, Jérôme; Yu, Yongjae; Barrón, Vidal; Torrent, José
2013-11-01
Magnetic minerals can undergo high pressures during their formation and subsequent evolution, which can modify both their intrinsic magnetic properties and remanent magnetization. Aluminum-substituted hematite (Al-hematite) occurs in significant proportion in many soils and sediments, especially in temperate and warm areas. In this work we investigated the effect of high hydrostatic pressures on the magnetic remanence of two series of synthetic Al-hematites. A pressure of 1.44 GPa resulted in 50% reduction of the isothermal remanent magnetization (IRM), which was more effective than alternating field (AF) demagnetization with the largest peak field of 120 mT. In addition, repeated application of the same pressure leads to further demagnetization. Aluminum substitution may increase the resistance to the pressure effect by decreasing particle size and generating defects in magnetic lattices, which results in an increase in coercivity. Our study contributes to understanding the effects of pressure on rocks from the interior of Earth and other planets as well as shocked planetary surfaces, which is significant for future planetary studies.
Premartensitic transition and relevant magnetic effects in Ni50Mn34In15.5Al0.5 alloy
Wu, Yuqin; Guo, Shaopu; Yu, Shuyun; Cheng, Hui; Wang, Ruilong; Xiao, Haibo; Xu, Lingfang; Xiong, Rui; Liu, Yong; Xia, Zhengcai; Yang, Changping
2016-01-01
Resistance measurement, in situ optical microscopic observation, thermal and magnetic measurements have been carried out on Ni50Mn34In15.5Al0.5 alloy. The existence of a pronounced premartensitic transition prior to martensitic transition can be characterized by microstructure evolution as well as exothermic peak and smooth decrease of resistance and magnetization with obvious hysteresis over a wide temperature range upon cooling. Consequently, the alloy undergoes two successive magneto-structural transitions consisting of premartensitic and martensitic transitions. Magnetoelastic coupling between magnetic and structural degrees of freedom would be responsible for the appearance of premartensitic transition, as evinced by the distinct shift of transitions temperatures to lower temperature with external applied field of 50 kOe. The inverse premartensitic transition induced by magnetic field results in large magnetoresistance, and contributes to the enhanced inverse magnetocaloric effect through enlarging the peak value and temperature interval of magnetic entropy change ΔSm. PMID:27183331
Patterson, Mark S; Dirksen, Maurits T; Ijsselmuiden, Alexander J; Amoroso, Giovanni; Slagboom, Ton; Laarman, Gerrit-Jan; Schultz, Carl; van Domburg, Ron T; Serruys, Patrick W; Kiemeneij, Ferdinand
2011-06-01
Aims Comparison of magnetic guidewire navigation in percutaneous coronary intervention (MPCI) vs. conventional percutaneous coronary intervention (CPCI) for the treatment of acute myocardial infarction. Methods and results We compared 65 sequential patients (mean age 61 ± 15 years) undergoing primary MPCI with those of 405 patients undergoing CPCI (mean age 61 ± 13 years). The major endpoint was contrast media use. Technical success and procedural outcomes were evaluated. Clinical demographics and angiographic characteristics of the two groups were similar, except for fewer patients with previous coronary artery bypass grafting (CABG) and hypertension in the CPCI group and fewer patients with diabetes in the MPCI group. The technical success rate was high in both the MPCI and CPCI groups (95.4 vs. 98%). There was significantly less contrast media usage in the MPCI compared with the CPCI group, median reduction of contrast media of 30 mL with an OR = 0.41 (0.21-0.81). Fluoroscopy times were significantly reduced for MPCI compared with CPCI, median reduction of 7.2 min with an OR = 0.42 (0.20-0.79). Conclusion This comparison indicates the feasibility and non-inferiority of magnetic navigation in performing primary PCI and suggests the possibility of reductions in contrast media use and fluoroscopy time compared with CPCI.
Storage-and-release flux rope eruptions in the laboratory: initial results and experimental plans
NASA Astrophysics Data System (ADS)
Myers, C. E.; Yamada, M.; Ji, H.; Yoo, J.; Jara-Almonte, J.; Lawrence, E. E.
2012-12-01
Solar eruptive events such as coronal mass ejections (CMEs) are thought to be driven by a sudden release of magnetic energy stored in the corona. In many cases, the pre-eruptive configuration is a non-potential magnetic structure that can be modeled as a line-tied magnetic flux rope. In spite of ever-improving observational capabilities, directly studying the evolution of coronal flux ropes remains a significant challenge. Thus, in order to further explore the mechanisms that drive solar eruptions, we must find novel ways to simulate the relevant physical system. To this end, we have constructed a new laboratory experiment to study storage-and-release flux rope eruptions. This experiment contains a carefully designed set of ``sub-photospheric" coils that produces an active-region-like potential field configuration that remains static throughout the discharge. An arched magnetic flux rope plasma is formed within this potential field configuration by driving electric current through two line-tied footpoints (copper electrodes). Over the course of the discharge, the plasma current is quasi-statically increased (to tens of kiloamperes over many Alfvén times) in order to slowly build up magnetic energy in the system. As the flux rope gains energy, it will expand away from the electrodes to a point where it is expected to undergo a dynamic eruption due to the onset of a loss-of-equilibrium [Forbes & Isenberg, Astrophys. J. 373, 294 (1991)] or the torus instability [Kliem & Török, Phys. Rev. Lett. 96, 255002 (2006)]. In these experiments, the structure of the background potential field configuration (i.e., the field decay index) can be varied to study its effect on the observed flux rope eruptions. Initial results from these experiment are presented, including images from a fast visible light camera and direct measurements from internal magnetic diagnostics. This research is supported by DoE Contract Number DE-AC02-09CH11466 and by the Center for Magnetic Self-Organization (CMSO).; Specially designed magnetic field coils (orange and blue) are used to produce an active-region-like potential field configuration within the vacuum vessel (gray). An arched magnetic flux rope plasma is formed by driving electric current along low-lying potential field lines (blue/green). As magnetic energy builds up in the flux rope, it will expand outward and possibly undergo a storage-and-release eruption.
Recent Advances in the Synthesis and Biomedical Applications of Nanocomposite Hydrogels
Spizzirri, Umile Gianfranco; Curcio, Manuela; Cirillo, Giuseppe; Spataro, Tania; Vittorio, Orazio; Picci, Nevio; Hampel, Silke; Iemma, Francesca; Nicoletta, Fiore Pasquale
2015-01-01
Hydrogels sensitive to electric current are usually made of polyelectrolytes and undergo erosion, swelling, de-swelling or bending in the presence of an applied electric field. The electrical conductivity of many polymeric materials used for the fabrication of biomedical devices is not high enough to achieve an effective modulation of the functional properties, and thus, the incorporation of conducting materials (e.g., carbon nanotubes and nanographene oxide) was proposed as a valuable approach to overcome this limitation. By coupling the biological and chemical features of both natural and synthetic polymers with the favourable properties of carbon nanostructures (e.g., cellular uptake, electromagnetic and magnetic behaviour), it is possible to produce highly versatile and effective nanocomposite materials. In the present review, the recent advances in the synthesis and biomedical applications of electro-responsive nanocomposite hydrogels are discussed. PMID:26473915
An introduction to NMR-based approaches for measuring protein dynamics
Kleckner, Ian R; Foster, Mark P
2010-01-01
Proteins are inherently flexible at ambient temperature. At equilibrium, they are characterized by a set of conformations that undergo continuous exchange within a hierarchy of spatial and temporal scales ranging from nanometers to micrometers and femtoseconds to hours. Dynamic properties of proteins are essential for describing the structural bases of their biological functions including catalysis, binding, regulation and cellular structure. Nuclear magnetic resonance (NMR) spectroscopy represents a powerful technique for measuring these essential features of proteins. Here we provide an introduction to NMR-based approaches for studying protein dynamics, highlighting eight distinct methods with recent examples, contextualized within a common experimental and analytical framework. The selected methods are (1) Real-time NMR, (2) Exchange spectroscopy, (3) Lineshape analysis, (4) CPMG relaxation dispersion, (5) Rotating frame relaxation dispersion, (6) Nuclear spin relaxation, (7) Residual dipolar coupling, (8) Paramagnetic relaxation enhancement. PMID:21059410
Parabolic dish collectors - A solar option
NASA Astrophysics Data System (ADS)
Truscello, V. C.
1981-05-01
A description is given of several parabolic-dish high temperature solar thermal systems currently undergoing performance trials. A single parabolic dish has the potential for generating 20 to 30 kW of electricity with fluid temperatures from 300 to 1650 C. Each dish is a complete power-producing unit, and may function either independently or as part of a group of linked modules. The two dish designs under consideration are of 11 and 12 meter diameters, yielding receiver operating temperatures of 925 and 815 C, respectively. The receiver designs described include (1) an organic working fluid (toluene) Rankine cycle engine; (2) a Brayton open cycle unit incorporating a hybrid combustion chamber and nozzle and a shaft-coupled permanent magnet alternator; and (3) a modified Stirling cycle device originally designed for automotive use. Also considered are thermal buffer energy storage and thermochemical transport and storage.
Recent Advances in the Synthesis and Biomedical Applications of Nanocomposite Hydrogels.
Spizzirri, Umile Gianfranco; Curcio, Manuela; Cirillo, Giuseppe; Spataro, Tania; Vittorio, Orazio; Picci, Nevio; Hampel, Silke; Iemma, Francesca; Nicoletta, Fiore Pasquale
2015-10-13
Hydrogels sensitive to electric current are usually made of polyelectrolytes and undergo erosion, swelling, de-swelling or bending in the presence of an applied electric field. The electrical conductivity of many polymeric materials used for the fabrication of biomedical devices is not high enough to achieve an effective modulation of the functional properties, and thus, the incorporation of conducting materials (e.g., carbon nanotubes and nanographene oxide) was proposed as a valuable approach to overcome this limitation. By coupling the biological and chemical features of both natural and synthetic polymers with the favourable properties of carbon nanostructures (e.g., cellular uptake, electromagnetic and magnetic behaviour), it is possible to produce highly versatile and effective nanocomposite materials. In the present review, the recent advances in the synthesis and biomedical applications of electro-responsive nanocomposite hydrogels are discussed.
[Progress in diagnosis and treatment of adrenal metastases tumor].
Wu, Chu-jun; Qiu, Min; Ma, Lu-lin
2015-08-18
The adrenal gland is a common site of metastases, only second to pulmonary, liver and bone. The prevalence of adrenal metastases in patients with a history of cancer is between 10%-25%.The most common sites of origin are cancers of the lung, kidney, breast, gastrointestinal tract, and skin (melanoma).The mainstays of adrenal metastases diagnosis are computerized tomogramphy (CT), magnetic resonance imaging (MRI), and positron emission tomogramphy (PET). All patients should undergo complete hormonal evaluation to rule out functional adrenal tumors. Adrenal biopsy should be reserved for cases in which the results of non-invasive techniques are equivocal. In patients with isolated adrenal metastases, adrenalectomy is recommended, because of improved overall survival. For the patient with unresectable adrenal metastases tumor, radiotherapy and ablative therapy are feasible and useful methods for controlling adrenal metastases and offer patients opportunities for improved survival.
The earth and the moon /Harold Jeffreys Lecture/.
NASA Technical Reports Server (NTRS)
Press, F.
1971-01-01
The internal structures of the earth and the moon are compared in the light of the latest extensive data on the earth structure, mobility of the earth outer layers, and the properties of lunar crust. The Monte Carlo method is applied to develop an earth model by a stepwise process beginning with a random distribution of two elastic velocities and the density as a function of de pth. Lunar seismic, magnetic, and rock analysis data are used to infer the properties of the moon. The marked planetological contrast between the earth and the moon is shown to consist in that the earth is highly differentiated and still undergoes a large-scale differentiation, while the moon has lost its volatiles in its early history and has a cold dynamically inactive shell which has been without basic changes for three billion years.
Liu, Zhi-dan; He, Jiang-bo; Guo, Si-si; Yang, Zhi-xin; Shen, Jun; Li, Xiao-yan; Liang, Wei; Shen, Wei-dong
2015-08-25
Although many patients with facial paralysis have obtained benefits or completely recovered after acupuncture or electroacupuncture therapy, it is still difficult to list intuitive evidence besides evaluation using neurological function scales and a few electrophysiologic data. Hence, the aim of this study is to use more intuitive and reliable detection techniques such as facial nerve magnetic resonance imaging (MRI), nerve electromyography, and F waves to observe changes in the anatomic morphology of facial nerves and nerve conduction before and after applying acupuncture or electroacupuncture, and to verify their effectiveness by combining neurological function scales. A total of 132 patients with Bell's palsy (grades III and IV in the House-Brackmann [HB] Facial Nerve Grading System) will be randomly divided into electroacupuncture, manual acupuncture, non-acupuncture, and medicine control groups. All the patients will be given electroacupuncture treatment after the acute period, except for patients in the medicine control group. The acupuncture or electroacupuncture treatments will be performed every 2 days until the patients recover or withdraw from the study. The primary outcome is analysis based on facial nerve functional scales (HB scale and Sunnybrook facial grading system), and the secondary outcome is analysis based on MRI, nerve electromyography and F-wave detection. All the patients will undergo MRI within 3 days after Bell's palsy onset for observation of the signal intensity and facial nerve swelling of the unaffected and affected sides. They will also undergo facial nerve electromyography and F-wave detection within 1 week after onset of Bell's palsy. Nerve function will be evaluated using the HB scale and Sunnybrook facial grading system at each hospital visit for treatment until the end of the study. The MRI, nerve electromyography, and F-wave detection will be performed again at 1 month after the onset of Bell's palsy. Chinese Clinical Trials Register identifier: ChiCTR-IPR-14005730. Registered on 23 December 2014.
Saccadic Eye Movements in Anorexia Nervosa
Phillipou, Andrea; Rossell, Susan Lee; Gurvich, Caroline; Hughes, Matthew Edward; Castle, David Jonathan; Nibbs, Richard Grant; Abel, Larry Allen
2016-01-01
Background Anorexia Nervosa (AN) has a mortality rate among the highest of any mental illness, though the factors involved in the condition remain unclear. Recently, the potential neurobiological underpinnings of the condition have become of increasing interest. Saccadic eye movement tasks have proven useful in our understanding of the neurobiology of some other psychiatric illnesses as they utilise known brain regions, but to date have not been examined in AN. The aim of this study was to investigate whether individuals with AN differ from healthy individuals in performance on a range of saccadic eye movements tasks. Methods 24 females with AN and 25 healthy individuals matched for age, gender and premorbid intelligence participated in the study. Participants were required to undergo memory-guided and self-paced saccade tasks, and an interleaved prosaccade/antisaccade/no-go saccade task while undergoing functional magnetic resonance imaging (fMRI). Results AN participants were found to make prosaccades of significantly shorter latency than healthy controls. AN participants also made an increased number of inhibitory errors on the memory-guided saccade task. Groups did not significantly differ in antisaccade, no-go saccade or self-paced saccade performance, or fMRI findings. Discussion The results suggest a potential role of GABA in the superior colliculus in the psychopathology of AN. PMID:27010196
Bacterially synthesized ferrite nanoparticles for magnetic hyperthermia applications.
Céspedes, Eva; Byrne, James M; Farrow, Neil; Moise, Sandhya; Coker, Victoria S; Bencsik, Martin; Lloyd, Jonathan R; Telling, Neil D
2014-11-07
Magnetic hyperthermia uses AC stimulation of magnetic nanoparticles to generate heat for cancer cell destruction. Whilst nanoparticles produced inside magnetotactic bacteria have shown amongst the highest reported heating to date, these particles are magnetically blocked so that strong heating occurs only for mobile particles, unless magnetic field parameters are far outside clinical limits. Here, nanoparticles extracellularly produced by the bacteria Geobacter sulfurreducens are investigated that contain Co or Zn dopants to tune the magnetic anisotropy, saturation magnetization and nanoparticle sizes, enabling heating within clinical field constraints. The heating mechanisms specific to either Co or Zn doping are determined from frequency dependent specific absorption rate (SAR) measurements and innovative AC susceptometry simulations that use a realistic model concerning clusters of polydisperse nanoparticles in suspension. Whilst both particle types undergo magnetization relaxation and show heating effects in water under low AC frequency and field, only Zn doped particles maintain relaxation combined with hysteresis losses even when immobilized. This magnetic heating process could prove important in the biological environment where nanoparticle mobility may not be possible. Obtained SARs are discussed regarding clinical conditions which, together with their enhanced MRI contrast, indicate that biogenic Zn doped particles are promising for combined diagnostics and cancer therapy.
Pulsating Magnetic Reconnection Driven by Three-Dimensional Flux-Rope Interactions.
Gekelman, W; De Haas, T; Daughton, W; Van Compernolle, B; Intrator, T; Vincena, S
2016-06-10
The dynamics of magnetic reconnection is investigated in a laboratory experiment consisting of two magnetic flux ropes, with currents slightly above the threshold for the kink instability. The evolution features periodic bursts of magnetic reconnection. To diagnose this complex evolution, volumetric three-dimensional data were acquired for both the magnetic and electric fields, allowing key field-line mapping quantities to be directly evaluated for the first time with experimental data. The ropes interact by rotating about each other and periodically bouncing at the kink frequency. During each reconnection event, the formation of a quasiseparatrix layer (QSL) is observed in the magnetic field between the flux ropes. Furthermore, a clear correlation is demonstrated between the quasiseparatrix layer and enhanced values of the quasipotential computed by integrating the parallel electric field along magnetic field lines. These results provide clear evidence that field lines passing through the quasiseparatrix layer are undergoing reconnection and give a direct measure of the nonlinear reconnection rate. The measurements suggest that the parallel electric field within the QSL is supported predominantly by electron pressure; however, resistivity may play a role.
Spin-orbit-driven magnetic structure and excitation in the 5d pyrochlore Cd 2Os 2O 7
Calder, Stuart A; Vale, James G.; Bogdanov, Nikolay; ...
2016-06-07
Here, much consideration has been given to the role of spin-orbit coupling (SOC) in 5d oxides, particularly on the formation of novel electronic states and manifested metal-insulator transitions (MITs). SOC plays a dominant role in 5d 5 iridates (Ir 4+), undergoing MITs both concurrent (pyrochlores) and separated (perovskites) from the onset of magnetic order. However, the role of SOC for other 5d configurations is less clear. For example, 5d 3 (Os 5+) systems are expected to have an orbital singlet with reduced effective SOC. The pyrochlore Cd 2Os 2O 7 nonetheless exhibits a MIT entwined with magnetic order phenomenologically similarmore » to pyrochlore iridates. Here, we resolve the magnetic structure in Cd 2Os 2O 7 with neutron diffraction and then via resonant inelastic X-ray scattering determine the salient electronic and magnetic energy scales controlling the MIT. In particular, SOC plays a subtle role in creating the electronic ground state but drives the magnetic order and emergence of a multiple spin-flip magnetic excitation.« less
Cognitive function and adherence of older adults undergoing hemodialysis.
Hain, Debra J
2008-01-01
As the number of older adults undergoing hemodialysis increases, it is important for nurses to consider cognitive impairment as a contributing factor to non-adherence. The purpose of this exploratory study was to identify cognitive markers that nurses can use to alert them to potential problems with adherence among older adults undergoing hemodialysis. Stories of the health challenge of making lifestyle change were analyzed with a linguistic analysis software program. A standardized instrument (3MS) that measures global cognitive function was administered. Determination of adherence level was the last activity of data collection. In this sample (n=63), 39.7% of the participants had evidence of cognitive impairment (3MS score less than 80); 58.2% of the 39.7% had evidence of non-adherence. There was a significant relationship between word use and cognitive function (p < .01). Cognitive impairment is prevalent among older adults undergoing hemodialysis and words might be a proxy for recognizing this.
NASA Astrophysics Data System (ADS)
Kubota, Yumi; Tanaka, Hidekazu; Ono, Toshio; Narumi, Yasuo; Kindo, Koichi
2015-03-01
The layered compound α -RuCl3 is composed of a honeycomb lattice of magnetic Ru3 + ions with the 4 d5 electronic state. We have investigated the magnetic properties of α -RuCl3 via magnetization and specific heat measurements using single crystals. It was observed that α -RuCl3 undergoes a structural phase transition at Tt≃150 K accompanied by fairly large hysteresis. This structural phase transition is expected to be similar to that observed in closely related CrCl3. The magnetizations and magnetic susceptibilities are strongly anisotropic, which mainly arise from the anisotropic g factors, i.e., ga b≃2.5 and gc≃0.4 for magnetic fields parallel and perpendicular to the a b plane, respectively. These g factors and the obtained entropy indicate that the effective spin of Ru3 + is one-half, which results from the low-spin state. Specific heat data show that magnetic ordering occurs in four steps at zero magnetic field. The successive magnetic phase transitions should be ascribed to the competition among exchange interactions. The magnetic phase diagram for H ∥a b is obtained. We discuss the strongly anisotropic g factors in α -RuCl3 and deduce that the exchange interaction is strongly XY-like. α -RuCl3 is magnetically described as a three-dimensionally coupled XY-like frustrated magnet on a honeycomb lattice.
Matsumoto, Y; Amano, T; Kato, T N; Hoshino, M
2015-02-27
Explosive phenomena such as supernova remnant shocks and solar flares have demonstrated evidence for the production of relativistic particles. Interest has therefore been renewed in collisionless shock waves and magnetic reconnection as a means to achieve such energies. Although ions can be energized during such phenomena, the relativistic energy of the electrons remains a puzzle for theory. We present supercomputer simulations showing that efficient electron energization can occur during turbulent magnetic reconnection arising from a strong collisionless shock. Upstream electrons undergo first-order Fermi acceleration by colliding with reconnection jets and magnetic islands, giving rise to a nonthermal relativistic population downstream. These results shed new light on magnetic reconnection as an agent of energy dissipation and particle acceleration in strong shock waves. Copyright © 2015, American Association for the Advancement of Science.
Adolescent Cannabis Use: What is the Evidence for Functional Brain Alteration?
Lorenzetti, Valentina; Alonso-Lana, Silvia; Youssef, George J; Verdejo-Garcia, Antonio; Suo, Chao; Cousijn, Janna; Takagi, Michael; Yücel, Murat; Solowij, Nadia
2016-01-01
Cannabis use typically commences during adolescence, a period during which the brain undergoes profound remodeling in areas that are high in cannabinoid receptors and that mediate cognitive control and emotion regulation. It is therefore important to determine the impact of adolescent cannabis use on brain function. We investigate the impact of adolescent cannabis use on brain function by reviewing the functional magnetic resonance imaging studies in adolescent samples. We systematically reviewed the literature and identified 13 functional neuroimaging studies in adolescent cannabis users (aged 13 to 18 years) performing working memory, inhibition and reward processing tasks. The majority of the studies found altered brain function, but intact behavioural task performance in adolescent cannabis users versus controls. The most consistently reported differences were in the frontal-parietal network, which mediates cognitive control. Heavier use was associated with abnormal brain function in most samples. A minority of studies controlled for the influence of confounders that can also undermine brain function, such as tobacco and alcohol use, psychopathology symptoms, family history of psychiatric disorders and substance use. Emerging evidence shows abnormal frontal-parietal network activity in adolescent cannabis users, particularly in heavier users. Brain functional alterations may reflect a compensatory neural mechanism that enables normal behavioural performance. It remains unclear if cannabis exposure drives these alterations, as substance use and mental health confounders have not been systematically examined. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.
Nepple, Jeffrey J; Wright, Rick W; Matava, Matthew J; Brophy, Robert H
2012-06-01
To better define the prevalence and location of full-thickness articular cartilage lesions in elite football players undergoing knee magnetic resonance imaging (MRI) at the National Football League (NFL) Invitational Combine and assess the association of these lesions with previous knee surgery. We performed a retrospective review of all participants in the NFL Combine undergoing a knee MRI scan from 2005 to 2009. Each MRI scan was reviewed for evidence of articular cartilage disease. History of previous knee surgery including anterior cruciate ligament reconstruction, meniscal procedures, and articular cartilage surgery was recorded for each athlete. Knees with a history of previous articular cartilage restoration surgery were excluded from the analysis. A total of 704 knee MRI scans were included in the analysis. Full-thickness articular cartilage lesions were associated with a history of any previous knee surgery (P < .001) and, specifically, previous meniscectomy (P < .001) but not with anterior cruciate ligament reconstruction (P = .7). Full-thickness lesions were present in 27% of knees with a previous meniscectomy compared with 12% of knees without any previous meniscal surgery. Full-thickness lesions in the lateral compartment were associated with previous lateral meniscectomy (P < .001); a similar relation was seen for medial meniscus tears in the medial compartment (P = .01). Full-thickness articular cartilage lesions of the knee were present in 17.3% of elite American football players at the NFL Combine undergoing MRI. The lateral compartment appears to be at greater risk for full-thickness cartilage loss. Previous knee surgery, particularly meniscectomy, is associated with these lesions. Level IV, therapeutic case series. Copyright © 2012 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Pasupathy, Sivabaskari; Tavella, Rosanna; Grover, Suchi; Raman, Betty; Procter, Nathan E K; Du, Yang Timothy; Mahadavan, Gnanadevan; Stafford, Irene; Heresztyn, Tamila; Holmes, Andrew; Zeitz, Christopher; Arstall, Margaret; Selvanayagam, Joseph; Horowitz, John D; Beltrame, John F
2017-09-05
Contemporary ST-segment-elevation myocardial infarction management involves primary percutaneous coronary intervention, with ongoing studies focusing on infarct size reduction using ancillary therapies. N-acetylcysteine (NAC) is an antioxidant with reactive oxygen species scavenging properties that also potentiates the effects of nitroglycerin and thus represents a potentially beneficial ancillary therapy in primary percutaneous coronary intervention. The NACIAM trial (N-acetylcysteine in Acute Myocardial Infarction) examined the effects of NAC on infarct size in patients with ST-segment-elevation myocardial infarction undergoing percutaneous coronary intervention. This randomized, double-blind, placebo-controlled, multicenter study evaluated the effects of intravenous high-dose NAC (29 g over 2 days) with background low-dose nitroglycerin (7.2 mg over 2 days) on early cardiac magnetic resonance imaging-assessed infarct size. Secondary end points included cardiac magnetic resonance-determined myocardial salvage and creatine kinase kinetics. Of 112 randomized patients with ST-segment-elevation myocardial infarction, 75 (37 in NAC group, 38 in placebo group) underwent early cardiac magnetic resonance imaging. Median duration of ischemia pretreatment was 2.4 hours. With background nitroglycerin infusion administered to all patients, those randomized to NAC exhibited an absolute 5.5% reduction in cardiac magnetic resonance-assessed infarct size relative to placebo (median, 11.0%; [interquartile range 4.1, 16.3] versus 16.5%; [interquartile range 10.7, 24.2]; P =0.02). Myocardial salvage was approximately doubled in the NAC group (60%; interquartile range, 37-79) compared with placebo (27%; interquartile range, 14-42; P <0.01) and median creatine kinase areas under the curve were 22 000 and 38 000 IU·h in the NAC and placebo groups, respectively ( P =0.08). High-dose intravenous NAC administered with low-dose intravenous nitroglycerin is associated with reduced infarct size in patients with ST-segment-elevation myocardial infarction undergoing percutaneous coronary intervention. A larger study is required to assess the impact of this therapy on clinical cardiac outcomes. Australian New Zealand Clinical Trials Registry. URL: http://www.anzctr.org.au/. Unique identifier: 12610000280000. © 2017 American Heart Association, Inc.
Kussman, Barry D; Wypij, David; Laussen, Peter C; Soul, Janet S; Bellinger, David C; DiNardo, James A; Robertson, Richard; Pigula, Frank A; Jonas, Richard A; Newburger, Jane W
2010-07-20
Near-infrared spectroscopy monitoring of cerebral oxygen saturation (rSo(2)) has become routine in many centers, but no studies have reported the relationship of intraoperative near-infrared spectroscopy to long-term neurodevelopmental outcomes after cardiac surgery. Of 104 infants undergoing biventricular repair without aortic arch reconstruction, 89 (86%) returned for neurodevelopmental testing at 1 year of age. The primary near-infrared spectroscopy variable was the integrated rSo(2) (area under the curve) for rSo(2)
Technique-associated outcomes in horses following large colon resection.
Pezzanite, Lynn M; Hackett, Eileen S
2017-11-01
To compare survival and complications in horses undergoing large colon resection with either sutured end-to-end or stapled functional end-to-end anastomoses. Retrospective cohort study. Twenty-six client-owned horses with gastrointestinal disease. Retrospective data were retrieved from the medical records of 26 horses undergoing colectomy, including 14 horses with sutured end-to-end and 12 horses with stapled functional end-to-end anastomoses, between 2003 and 2016. Records were evaluated for signalment, medical and surgical treatments, and survival to hospital discharge. Long-term follow-up was obtained through owner contact. Continuous variables were compared with Mann-Whitney tests. Fisher's exact testing was used to compare survival to hospital discharge. Survival time was compared by constructing Kaplan-Meier survival curves and performing log-rank curve comparison testing. Mean age of horses undergoing colectomy was 13 years. Reason for colectomy was prophylaxis (12) or salvage (14). Mean surgical time was 169 minutes. Mean hospitalization time was 9 days, which did not differ with anastomosis type (P = .62). Nine of 12 horses undergoing stapled functional end-to-end anastomosis and 12 of 14 horses undergoing sutured end-to-end anastomosis survived to hospital discharge (P = .63). Survival time did not differ with anastomosis technique (P = .35). Short- and long-term survival outcomes are not different between sutured end-to-end or stapled functional end-to-end anastomoses in horses undergoing colectomy. © 2017 The American College of Veterinary Surgeons.
Sensing the effects of mouth breathing by using 3-tesla MRI
NASA Astrophysics Data System (ADS)
Park, Chan-A.; Kang, Chang-Ki
2017-06-01
We investigated the effects of mouth breathing and typical nasal breathing on brain function by using blood-oxygenation-level-dependent (BOLD) functional magnetic resonance imaging (fMRI). The study had two parts: the first test was a simple contrast between mouth and nasal breathing, and the second test involved combined breathing modes, e.g., mouth inspiration and nasal expiration. Eleven healthy participants performed the combined breathing task while undergoing 3T fMRI. In the group-level analysis, contrast images acquired by using an individual participantlevel analysis were processed using the one-sample t test. We also conducted a region-of-interest analysis comparing signal intensity changes between the breathing modes; the region was selected using an automated anatomical labeling map. The results demonstrated that the BOLD signal in the hippocampus and brainstem was significantly decreased in mouth breathing relative to nasal breathing. On the other hand, both the precentral and postcentral gyri showed activation that was more significant in mouth breathing compared to nasal breathing. This study suggests that the BOLD activity patterns between mouth and nasal breathing may be induced differently, especially in the hippocampus, which could provide clues to explain the effects on brain cognitive function due to mouth breathing.
Ramsay, Ian S.; Nienow, Tasha M.; Marggraf, Matthew P.; MacDonald, Angus W.
2017-01-01
Background Patients with schizophrenia have shown cognitive improvements following cognitive remediation, but the neuroplastic changes that support these processes are not fully understood. Aims To use a triple-blind, placebo-controlled trial to examine neural activation before and after cognitive remediation or a computer skills training (CST) placebo (trial registration: NCT00995553)). Method Twenty-seven participants underwent functional magnetic resonance imaging before and after being randomised to either cognitive remediation intervention or CST. Participants completed two variants of the N-back task during scanning and were assessed on measures of cognition, functional capacity, community functioning and symptoms. Results We observed a group × time interaction in the left prefrontal cortex, wherein the cognitive remediation group showed increased activation. These changes correlated with improved task accuracy within the cognitive remediation group, whereas there was no relationship between changes in activation in untrained cognitive measures. Significant changes were not observed in other hypothesised areas for the cognitive remediation group. Conclusions We replicated the finding that cognitive remediation increases left lateral prefrontal activation during a working memory task in patients with schizophrenia, suggesting this may be an important neural target for these types of interventions. PMID:28153927
Ramsay, Ian S; Nienow, Tasha M; Marggraf, Matthew P; MacDonald, Angus W
2017-03-01
Background Patients with schizophrenia have shown cognitive improvements following cognitive remediation, but the neuroplastic changes that support these processes are not fully understood. Aims To use a triple-blind, placebo-controlled trial to examine neural activation before and after cognitive remediation or a computer skills training (CST) placebo (trial registration: NCT00995553)). Method Twenty-seven participants underwent functional magnetic resonance imaging before and after being randomised to either cognitive remediation intervention or CST. Participants completed two variants of the N-back task during scanning and were assessed on measures of cognition, functional capacity, community functioning and symptoms. Results We observed a group × time interaction in the left prefrontal cortex, wherein the cognitive remediation group showed increased activation. These changes correlated with improved task accuracy within the cognitive remediation group, whereas there was no relationship between changes in activation in untrained cognitive measures. Significant changes were not observed in other hypothesised areas for the cognitive remediation group. Conclusions We replicated the finding that cognitive remediation increases left lateral prefrontal activation during a working memory task in patients with schizophrenia, suggesting this may be an important neural target for these types of interventions. © The Royal College of Psychiatrists 2017.
Temperature and magnetic field induced multiple magnetic transitions in DyAg(2).
Arora, Parul; Chattopadhyay, M K; Sharath Chandra, L S; Sharma, V K; Roy, S B
2011-02-09
The magnetic properties of the rare-earth intermetallic compound DyAg(2) are studied in detail with the help of magnetization and heat capacity measurements. It is shown that the multiple magnetic phase transitions can be induced in DyAg(2) both by temperature and magnetic field. The detailed magnetic phase diagram of DyAg(2) is determined experimentally. It was already known that DyAg(2) undergoes an incommensurate to commensurate antiferromagnetic phase transition close to 10 K. The present experimental results highlight the first order nature of this phase transition, and show that this transition can be induced by magnetic field as well. It is further shown that another isothermal magnetic field induced transition or metamagnetic transition exhibited by DyAg(2) at still lower temperatures is also of first order nature. The multiple magnetic phase transitions in DyAg(2) give rise to large peaks in the temperature dependence of the heat capacity below 17 K, which indicates its potential as a magnetic regenerator material for cryocooler related applications. In addition it is found that because of the presence of the temperature and field induced magnetic phase transitions, and because of short range magnetic correlations deep inside the paramagnetic regime, DyAg(2) exhibits a fairly large magnetocaloric effect over a wide temperature window, e.g., between 10 and 60 K.
Duval, Elizabeth R; Garfinkel, Sarah N; Swain, James E; Evans, Gary W; Blackburn, Erika K; Angstadt, Mike; Sripada, Chandra S; Liberzon, Israel
2017-02-01
Childhood poverty is a risk factor for poorer cognitive performance during childhood and adulthood. While evidence linking childhood poverty and memory deficits in adulthood has been accumulating, underlying neural mechanisms are unknown. To investigate neurobiological links between childhood poverty and adult memory performance, we used functional magnetic resonance imaging (fMRI) during a visuospatial memory task in healthy young adults with varying income levels during childhood. Participants were assessed at age 9 and followed through young adulthood to assess income and related factors. During adulthood, participants completed a visuospatial memory task while undergoing MRI scanning. Patterns of neural activation, as well as memory recognition for items, were assessed to examine links between brain function and memory performance as it relates to childhood income. Our findings revealed associations between item recognition, childhood income level, and hippocampal activation. Specifically, the association between hippocampal activation and recognition accuracy varied as a function of childhood poverty, with positive associations at higher income levels, and negative associations at lower income levels. These prospective findings confirm previous retrospective results detailing deleterious effects of childhood poverty on adult memory performance. In addition, for the first time, we identify novel neurophysiological correlates of these deficits localized to hippocampus activation. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
Kashida, Yumi; Otsubo, Toshiaki; Hanaya, Ryosuke; Kodabashi, Atsushi; Tsumagari, Noriko; Sugata, Sei; Hosoyama, Hiroshi; Iida, Koji; Nakamura, Katsumi; Tokimura, Hiroshi; Fujimoto, Toshiro; Arita, Kazunori
2016-08-01
The Wada test has been the gold standard for determining hemispheric language dominance (HLD) in the presurgical evaluation of patients scheduled for neurosurgical procedures. As it poses inherent risks associated with intra-arterial catheter techniques and as it occasionally fails to indicate language dominance, an alternative reliable test is needed. We quantitatively assessed the results of functional magnetic resonance imaging (fMRI) using the Shiritori task, a Japanese word chain, to identify the threshold for correctly predicting HLD. The subjects were 28 patients with intractable epilepsy scheduled to undergo the Wada test and focus resection. We set the region of interest (ROI) on the bilateral Brodmann areas 44 and 45 (BA 44 and 45). To compare the functional activity at both ROIs we calculated the language laterality index (LI) using the formula: [VL-VR]/[VL+VR]×100, where VL and VR indicated the number of activated voxels in the left and right ROIs, respectively. As 2 patients were excluded due to the lack of activation in either ROI, the final study population consisted of 26 patients. By the Wada test, HLD was left in 20, right in 3, and equivocal in 3. At a cut-off of LI+50, the predictive sensitivity and specificity for left HLD were 85% (17/20) and 100%; right HLD was predicted in a single patient (sensitivity 33.3%, specificity 100%). The fMRI using the Shiritori task showed good activation in ROI of BA 44 and 45. At a cut-off of LI+50, LI of BA 44 and 45 predicted HLD identified by the Wada test with high specificity. Copyright © 2016 Elsevier B.V. All rights reserved.
Yap, Timothy A.; Yan, Li; Patnaik, Amita; Tunariu, Nina; Biondo, Andrea; Fearen, Ivy; Papadopoulos, Kyriakos P.; Olmos, David; Baird, Richard; Delgado, Liliana; Tetteh, Ernestina; Beckman, Robert A.; Lupinacci, Lisa; Riisnaes, Ruth; Decordova, Shaun; Heaton, Simon P.; Swales, Karen; deSouza, Nandita M; Leach, Martin O.; Garrett, Michelle D.; Sullivan, Daniel M.; de Bono, Johann S.; Tolcher, Anthony W.
2014-01-01
Purpose Multiple cancers harbor genetic aberrations that impact AKT signaling. MK-2206 is a potent pan-AKT inhibitor with a maximum tolerated dose (MTD) previously established at 60mg on alternate days (QOD). Due to a long half-life (60-80h), a weekly (QW) MK-2206 schedule was pursued to compare intermittent QW and continuous QOD dosing. Experimental Design Patients with advanced cancers were enrolled onto a QW dose-escalation phase I study to investigate the safety and pharmacokinetic-pharmacodynamic profiles of tumor and platelet-rich plasma (PRP). The QOD MTD of MK-2206 was also assessed in patients with ovarian and castration-resistant prostate cancers, and patients with advanced cancers undergoing multiparametric functional magnetic resonance imaging (MRI) studies, including dynamic contrast-enhanced MRI, diffusion-weighted imaging, magnetic resonance spectroscopy and intrinsic susceptibility-weighted MRI. Results Seventy-one patients were enrolled; 38 patients had 60mg MK-2206 QOD, while 33 received MK-2206 at 90mg, 135mg, 150mg, 200mg, 250mg, and 300mg QW. The QW MK-2206 MTD was established at 200mg following dose-limiting rash at 250mg and 300mg. QW dosing appeared to be similarly tolerated to QOD, with toxicities including rash, gastrointestinal symptoms, fatigue, and hyperglycemia. Significant AKT pathway blockade was observed with both continuous QOD and intermittent QW dosing of MK-2206 in serially-obtained tumor and PRP specimens. The functional imaging studies demonstrated that complex multiparametric MRI protocols may be effectively implemented in a phase I trial. Conclusions MK-2206 safely results in significant AKT pathway blockade in QOD and QW schedules. The intermittent dose of 200mg QW is currently used in phase II MK-2206 monotherapy and combination studies. PMID:25239610
Yap, Timothy A; Yan, Li; Patnaik, Amita; Tunariu, Nina; Biondo, Andrea; Fearen, Ivy; Papadopoulos, Kyriakos P; Olmos, David; Baird, Richard; Delgado, Liliana; Tetteh, Ernestina; Beckman, Robert A; Lupinacci, Lisa; Riisnaes, Ruth; Decordova, Shaun; Heaton, Simon P; Swales, Karen; deSouza, Nandita M; Leach, Martin O; Garrett, Michelle D; Sullivan, Daniel M; de Bono, Johann S; Tolcher, Anthony W
2014-11-15
Multiple cancers harbor genetic aberrations that impact AKT signaling. MK-2206 is a potent pan-AKT inhibitor with a maximum tolerated dose (MTD) previously established at 60 mg on alternate days (QOD). Due to a long half-life (60-80 hours), a weekly (QW) MK-2206 schedule was pursued to compare intermittent QW and continuous QOD dosing. Patients with advanced cancers were enrolled in a QW dose-escalation phase I study to investigate the safety and pharmacokinetic-pharmacodynamic profiles of tumor and platelet-rich plasma (PRP). The QOD MTD of MK-2206 was also assessed in patients with ovarian and castration-resistant prostate cancers and patients with advanced cancers undergoing multiparametric functional magnetic resonance imaging (MRI) studies, including dynamic contrast-enhanced MRI, diffusion-weighted imaging, magnetic resonance spectroscopy, and intrinsic susceptibility-weighted MRI. A total of 71 patients were enrolled; 38 patients had 60 mg MK-2206 QOD, whereas 33 received MK-2206 at 90, 135, 150, 200, 250, and 300 mg QW. The QW MK-2206 MTD was established at 200 mg following dose-limiting rash at 250 and 300 mg. QW dosing appeared to be similarly tolerated to QOD, with toxicities including rash, gastrointestinal symptoms, fatigue, and hyperglycemia. Significant AKT pathway blockade was observed with both continuous QOD and intermittent QW dosing of MK-2206 in serially obtained tumor and PRP specimens. The functional imaging studies demonstrated that complex multiparametric MRI protocols may be effectively implemented in a phase I trial. Treatment with MK-2206 safely results in significant AKT pathway blockade in QOD and QW schedules. The intermittent dose of 200 mg QW is currently used in phase II MK-2206 monotherapy and combination studies (NCT00670488). ©2014 American Association for Cancer Research.
The critical 1-arm exponent for the ferromagnetic Ising model on the Bethe lattice
NASA Astrophysics Data System (ADS)
Heydenreich, Markus; Kolesnikov, Leonid
2018-04-01
We consider the ferromagnetic nearest-neighbor Ising model on regular trees (Bethe lattice), which is well-known to undergo a phase transition in the absence of an external magnetic field. The behavior of the model at critical temperature can be described in terms of various critical exponents; one of them is the critical 1-arm exponent ρ which characterizes the rate of decay of the (root) magnetization as a function of the distance to the boundary. The crucial quantity we analyze in this work is the thermal expectation of the root spin on a finite subtree, where the expected value is taken with respect to a probability measure related to the corresponding finite-volume Hamiltonian with a fixed boundary condition. The spontaneous magnetization, which is the limit of this thermal expectation in the distance between the root and the boundary (i.e., in the height of the subtree), is known to vanish at criticality. We are interested in a quantitative analysis of the rate of this convergence in terms of the critical 1-arm exponent ρ. Therefore, we rigorously prove that ⟨σ0⟩ n +, the thermal expectation of the root spin at the critical temperature and in the presence of the positive boundary condition, decays as ⟨σ0 ⟩ n +≈n-1/2 (in a rather sharp sense), where n is the height of the tree. This establishes the 1-arm critical exponent for the Ising model on regular trees (ρ =1/2 ).
Plasma Turbulence in Earth's Magnetotail Observed by the Magnetospheric Multiscale Mission
NASA Astrophysics Data System (ADS)
Mackler, D. A.; Avanov, L. A.; Boardsen, S. A.; Pollock, C. J.
2017-12-01
Magnetic reconnection, a process in which the magnetic topology undergoes multi-scale changes, is a significant mechanism for particle energization as well as energy dissipation. Reconnection is observed to occur in thin current sheets generated between two regions of magnetized plasma merging with a non-zero shear angle. Within a thinning current sheet, the dominant scale size approaches first the ion and then electron kinetic scale. The plasma becomes demagnetized, field lines transform, then once again the plasma becomes frozen-in. The reconnection process accelerates particles, leading to heated jets of plasma. Turbulence is another fundamental process in collision less plasmas. Despite decades of turbulence studies, an essential science question remains as to how turbulent energy dissipates at small scales by heating and accelerating particles. Turbulence in both plasmas and fluids has a fundamental property in that it follows an energy cascade into smaller scales. Energy introduced into a fluid or plasma can cause large scale motion, introducing vorticity, which merge and interact to make increasingly smaller eddies. It has been hypothesized that turbulent energy in magnetized plasmas may be dissipated by magnetic reconnection, just as viscosity dissipates energy in neutral fluid turbulence. The focus of this study is to use the new high temporal resolution suite of instruments on board the Magnetospheric MultiScale (MMS) mission to explore this hypothesis. An observable feature of the energy cascade in a turbulent magnetized plasma is its similarity to classical hydrodynamics in that the Power Spectral Density (PSD) of turbulent fluctuations follows a Kolmogorov-like power law (Image-5/3). We use highly accurate (0.1 nT) Flux Gate Magnetometer (FGM) data to derive the PSD as a function of frequency in the magnetic fluctuations. Given that we are able to confirm the turbulent nature of the flow field; we apply the method of Partial Variance of Increments (PVI) to search for localized gradient steepening where turbulent dissipation may be occurring. Additionally, we take advantage of multi-spacecraft observations to compute the current density in the turbulent region. This analysis is done over 15 contiguous burst periods on the afternoon of 6 July 2017, allowing a wide spectral range from 0.01-64 Hz.
NASA Astrophysics Data System (ADS)
Mackler, D. A.; Avanov, L. A.; Boardsen, S. A.; Giles, B. L.; Pollock, C.; Smith, S. E.; Uritsky, V. M.
2016-12-01
Magnetic reconnection, a process in which the magnetic topology undergoes multi-scale changes, is a significant mechanism for particle energization as well as energy dissipation. Reconnection is observed to occur in thin current sheets generated between two regions of magnetized plasma merging with a non-zero shear angle. Within a thinning current sheet, the dominant scale size approaches first the ion and then electron kinetic scale. The plasma becomes demagnetized, field lines transform, then once again the plasma becomes frozen-in. The reconnection process accelerates particles, leading to heated jets of plasma. Turbulence is another fundamental process in collisionless plasmas. Despite decades of turbulence studies, an essential science question remains as to how turbulent energy dissipates at small scales by heating and accelerating particles. Turbulence in both plasmas and fluids has a fundamental property in that it follows an energy cascade into smaller scales. Energy introduced into a fluid or plasma can cause large scale motion, introducing vorticity, which merge and interact to make increasingly smaller eddies. It has been hypothesized that turbulent energy in magnetized plasmas may be dissipated by magnetic reconnection, just as viscosity dissipates energy in neutral fluid turbulence. The focus of this study is to use the new high temporal resolution suite of instruments on board the Magnetospheric MultiScale (MMS) mission to explore this hypothesis. An observable feature of the energy cascade in a turbulent magnetized plasma is its similarity to classical hydrodynamics in that the Power Spectral Density (PSD) of turbulent fluctuations follows a Kolmogorov-like power law (f -5/3). We use highly accurate (0.1 nT) Flux Gate Magnetometer (FGM) data to derive the PSD as a function of frequency in the magnetic fluctuations. Given that we are able to confirm the turbulent nature of the flow field; we apply the method of Partial Variance of Increments (PVI) to search for localized gradient steepening where turbulent dissipation may be occurring. Additionally, we take advantage of multi-spacecraft observations to compute the current density in the turbulent region. This analysis is done over multiple burst periods during MMS' first sub-solar apogee pass from November 2015 to January 2016.
Magnet foreign body ingestion: rare occurrence but big consequences.
Sola, Richard; Rosenfeld, Eric H; Yu, Yangyang R; St Peter, Shawn D; Shah, Sohail R
2017-08-24
To review the outcomes of magnet ingestions from two children's hospitals and develop a clinical management pathway. Children <18years old who ingested a magnet were reviewed from 1/2011 to 6/2016 from two tertiary center children's hospitals. Demographics, symptoms, management and outcomes were analyzed. From 2011 to 2016, there were 89 magnet ingestions (50 from hospital 1 and 39 from hospital 2); 50 (56%) were males. Median age was 7.9 (4.0-12.0) years; 60 (67%) presented with multiple magnets or a magnet and a second metallic co-ingestion. Suspected locations found on imaging were: stomach (53%), small bowel (38%), colon (23%) and esophagus (3%). Only 35 patients (39%) presented with symptoms and the most common symptom was abdominal pain (33%). 42 (47%) patients underwent an intervention, in which 20 (23%) had an abdominal operation. For those undergoing abdominal surgery, an exact logistic regression model identified multiple magnets or a magnet and a second metallic object co-ingestion (OR 12.9; 95% CI, 2.4 - Infinity) and abdominal pain (OR 13.0; 95% CI, 3.2-67.8) as independent risk factors. Magnets have a high risk of requiring surgical intervention for removal. Therefore, we developed a management algorithm for magnet ingestion. Level III. Copyright © 2017 Elsevier Inc. All rights reserved.
Oberacker, Eva; Paul, Katharina; Huelnhagen, Till; Oezerdem, Celal; Winter, Lukas; Pohlmann, Andreas; Boehmert, Laura; Stachs, Oliver; Heufelder, Jens; Weber, Andreas; Rehak, Matus; Seibel, Ira; Niendorf, Thoralf
2017-10-01
Proton radiation therapy (PRT) is a standard treatment of uveal melanoma. PRT patients undergo implantation of ocular tantalum markers (OTMs) for treatment planning. Ultra-high-field MRI is a promising technique for 3D tumor visualization and PRT planning. This work examines MR safety and compatibility of OTMs at 7.0 Tesla. MR safety assessment included deflection angle measurements (DAMs), electromagnetic field (EMF) simulations for specific absorption rate (SAR) estimation, and temperature simulations for examining radiofrequency heating using a bow-tie dipole antenna for transmission. MR compatibility was assessed by susceptibility artifacts in agarose, ex vivo pig eyes, and in an ex vivo tumor eye using gradient echo and fast spin-echo imaging. DAM (α < 1 °) demonstrated no risk attributed to magnetically induced OTM deflection. EMF simulations showed that an OTM can be approximated by a disk, demonstrated the need for averaging masses of m ave = 0.01 g to accommodate the OTM, and provided SAR 0.01g,maximum = 2.64 W/kg (P in = 1W) in OTM presence. A transfer function was derived, enabling SAR 0.01g estimation for individual patient scenarios without the OTM being integrated. Thermal simulations revealed minor OTM-related temperature increase (δT < 15 mK). Susceptibility artifact size (<8 mm) and location suggest no restrictions for MRI of the nervus opticus. OTMs are not a per se contraindication for MRI. Magn Reson Med 78:1533-1546, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.
Acute vertigo in an anesthesia provider during exposure to a 3T MRI scanner
Gorlin, Andrew; Hoxworth, Joseph M; Pavlicek, William; Thunberg, Christopher A; Seamans, David
2015-01-01
Vertigo induced by exposure to the magnetic field of a magnetic resonance imaging (MRI) scanner is a well-known phenomenon within the radiology community but is not widely appreciated by other clinical specialists. Here, we describe a case of an anesthetist experiencing acute vertigo while providing sedation to a patient undergoing a 3 Tesla MRI scan. After discussing previous reports, and the evidence surrounding MRI-induced vertigo, we review potential etiologies that include the effects of both static and time-varying magnetic fields on the vestibular apparatus. We conclude our review by discussing the occupational standards that exist for MRI exposure and methods to minimize the risks of MRI-induced vertigo for clinicians working in the MRI environment. PMID:25792858
Porous silicon nanoparticles as biocompatible contrast agents for magnetic resonance imaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gongalsky, M. B., E-mail: mgongalsky@gmail.com; Kargina, Yu. V.; Osminkina, L. A.
2015-12-07
We propose porous silicon nanoparticles (PSi NPs) with natural oxide coating as biocompatible and bioresorbable contrast agents for magnetic resonant imaging (MRI). A strong shortening of the transversal proton relaxation time (T{sub 2}) was observed for aqueous suspensions of PSi NPs, whereas the longitudinal relaxation time (T{sub 1}) changed moderately. The longitudinal and transversal relaxivities are estimated to be 0.03 and 0.4 l/(g·s), respectively, which are promising for biomedical studies. The proton relaxation is suggested to undergo via the magnetic dipole-dipole interaction with Si dangling bonds on surfaces of PSi NPs. MRI experiments with phantoms have revealed the remarkable contrastingmore » properties of PSi NPs for medical diagnostics.« less
Brajuskovic, V.; Barrows, F.; Phatak, C.; ...
2016-10-03
Artificial spin ice lattices have emerged as model systems for studying magnetic frustration in recent years. Most work to date has looked at periodic artificial spin ice lattices. In this paper, we observe frustration effects in quasicrystal artificial spin ice lattices that lack translational symmetry and contain vertices with different numbers of interacting elements. We find that as the lattice state changes following demagnetizing and annealing, specific vertex motifs retain low-energy configurations, which excites other motifs into higher energy configurations. In addition, we find that unlike the magnetization reversal process for periodic artificial spin ice lattices, which occurs through 1Dmore » avalanches, quasicrystal lattices undergo reversal through a dendritic 2D avalanche mechanism.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brajuskovic, V.; Barrows, F.; Phatak, C.
Artificial spin ice lattices have emerged as model systems for studying magnetic frustration in recent years. Most work to date has looked at periodic artificial spin ice lattices. In this paper, we observe frustration effects in quasicrystal artificial spin ice lattices that lack translational symmetry and contain vertices with different numbers of interacting elements. We find that as the lattice state changes following demagnetizing and annealing, specific vertex motifs retain low-energy configurations, which excites other motifs into higher energy configurations. In addition, we find that unlike the magnetization reversal process for periodic artificial spin ice lattices, which occurs through 1Dmore » avalanches, quasicrystal lattices undergo reversal through a dendritic 2D avalanche mechanism.« less
Increase in stability of cellulase immobilized on functionalized magnetic nanospheres
NASA Astrophysics Data System (ADS)
Zhang, Wenjuan; Qiu, Jianhui; Feng, Huixia; Zang, Limin; Sakai, Eiichi
2015-02-01
Functionalized magnetic nanospheres were prepared by co-condensation of tetraethylorthosilicate with three different amino-silanes: 3-(2-aminoethylamino propyl)-triethoxysilane (AEAPTES), 3-(2-aminoethylamino propyl)-trimethoxysilane (AEAPTMES) and 3-aminopropyltriethoxysilane (APTES). Then three functionalized magnetic nanospheres were used as supports for immobilization of cellulase. The three functionalized magnetic nanospheres with core-shell morphologies exhibited higher capacity for cellulase immobilization than unfunctionalized magnetic nanospheres. The increasing of surface charge of functionalized magnetic nanospheres leads to an enhancement of the capacity of cellulase immobilization. Particularly, AEAPTMES with methoxy groups was favored to be hydrolyzed and grafted on unfunctionalized magnetic nanospheres than the others. AEAPTMES functionalized magnetic nanospheres with the highest zeta potential (29 mV) exhibited 87% activity recovery and the maximum amount of immobilized cellulase was 112 mg/g support at concentration of initial cellulase of 8 mg/mL. Immobilized cellulase on AEAPTMES functionalized magnetic nanospheres had higher temperature stability and broader pH stability than other immobilized cellulases and free cellulase. In particular, it can be used in about 40 °C, demonstrating the potential of biofuel production using this immobilized cellulase.
Nir, Yuval; Mukamel, Roy; Dinstein, Ilan; Privman, Eran; Harel, Michal; Fisch, Lior; Gelbard-Sagiv, Hagar; Kipervasser, Svetlana; Andelman, Fani; Neufeld, Miri Y; Kramer, Uri; Arieli, Amos; Fried, Itzhak; Malach, Rafael
2009-01-01
Animal studies have shown robust electrophysiological activity in the sensory cortex in the absence of stimuli or tasks. Similarly, recent human functional magnetic resonance imaging (fMRI) revealed widespread, spontaneously emerging cortical fluctuations. However, it is unknown what neuronal dynamics underlie this spontaneous activity in the human brain. Here we studied this issue by combining bilateral single-unit, local field potentials (LFPs) and intracranial electrocorticography (ECoG) recordings in individuals undergoing clinical monitoring. We found slow (<0.1 Hz, following 1/f-like profiles) spontaneous fluctuations of neuronal activity with significant interhemispheric correlations. These fluctuations were evident mainly in neuronal firing rates and in gamma (40–100 Hz) LFP power modulations. Notably, the interhemispheric correlations were enhanced during rapid eye movement and stage 2 sleep. Multiple intracranial ECoG recordings revealed clear selectivity for functional networks in the spontaneous gamma LFP power modulations. Our results point to slow spontaneous modulations in firing rate and gamma LFP as the likely correlates of spontaneous fMRI fluctuations in the human sensory cortex. PMID:19160509
Pfeifer, Jennifer H; Lieberman, Matthew D; Dapretto, Mirella
2007-08-01
Previous neuroimaging research with adults suggests that the medial prefrontal cortex (MPFC) and the medial posterior parietal cortex (MPPC) are engaged during self-knowledge retrieval processes. However, this has yet to be assessed in a developmental sample. Twelve children and 12 adults (average age = 10.2 and 26.1 years, respectively) reported whether short phrases described themselves or a highly familiar other (Harry Potter) while undergoing functional magnetic resonance imaging. In both children and adults, the MPFC was relatively more active during self- than social knowledge retrieval, and the MPPC was relatively more active during social than self-knowledge retrieval. Direct comparisons between children and adults indicated that children activated the MPFC during self-knowledge retrieval to a much greater extent than adults. The particular regions of the MPPC involved varied between the two groups, with the posterior precuneus engaged by adults, but the anterior precuneus and posterior cingulate engaged by children. Only children activated the MPFC significantly above baseline during self-knowledge retrieval. Implications for social cognitive development and the processing functions performed by the MPFC are discussed.
Molecular Imaging in Synthetic Biology, and Synthetic Biology in Molecular Imaging.
Gilad, Assaf A; Shapiro, Mikhail G
2017-06-01
Biomedical synthetic biology is an emerging field in which cells are engineered at the genetic level to carry out novel functions with relevance to biomedical and industrial applications. This approach promises new treatments, imaging tools, and diagnostics for diseases ranging from gastrointestinal inflammatory syndromes to cancer, diabetes, and neurodegeneration. As these cellular technologies undergo pre-clinical and clinical development, it is becoming essential to monitor their location and function in vivo, necessitating appropriate molecular imaging strategies, and therefore, we have created an interest group within the World Molecular Imaging Society focusing on synthetic biology and reporter gene technologies. Here, we highlight recent advances in biomedical synthetic biology, including bacterial therapy, immunotherapy, and regenerative medicine. We then discuss emerging molecular imaging approaches to facilitate in vivo applications, focusing on reporter genes for noninvasive modalities such as magnetic resonance, ultrasound, photoacoustic imaging, bioluminescence, and radionuclear imaging. Because reporter genes can be incorporated directly into engineered genetic circuits, they are particularly well suited to imaging synthetic biological constructs, and developing them provides opportunities for creative molecular and genetic engineering.
NASA Astrophysics Data System (ADS)
Nematov, M. G.; Salem, M. M.; Azim, U.; Akhmat, M.; Morchenko, A. T.; Yudanov, N. A.; Panina, L. V.
2018-02-01
The structural and magnetic properties of amorphous ferromagnetic microwires can undergo significant measurements under the action of external mechanical stresses and heat treatment. The study of transformations occurring in this case is important for designing various sensors of mechanical stresses, loading, and temperature and also for inducing in the wires a certain type of magnetic anisotropy that plays a significant role in the realization of various effects in them. In this work, the influence of external stresses and annealing on the processes of the magnetization and the magnetic impedance of Co71Fe5B11Si10Cr3 microwires having a low positive magnetostriction ( 10-8) in amorphous state has been studied. The influence of external stresses leads to a sharp change in the character of the magnetization reversal curve, which was due to the change in the sign of the magnetostriction and the type of magnetic anisotropy. The amplitude of higher harmonics and the value of the magnetic impedance, respectively, are sensitive to mechanical stresses. Elastic stresses in the wires with a partial crystallization do not lead to a marked change in the magnetic properties; however, annealing can lead to a substantial increase in the axial magnetic anisotropy of the wires existing in the stressed state. The experimental results are analyzed in the framework of a magnetostriction model of induced magnetic anisotropy.
Personality, function and satisfaction in patients undergoing total hip or knee replacement.
Ramaesh, Rishikesan; Jenkins, Paul; Lane, Judith V; Knight, Sara; Macdonald, Deborah; Howie, Colin
2014-03-01
The aim of this study was to investigate the relationships between personality and joint-specific function, general physical and general mental health in patients undergoing total hip (THA) and knee arthroplasty (TKA). One hundred and eighty-four patients undergoing THA and 205 undergoing TKA were assessed using the Eysneck Personality Questionnaire, brief version (EPQ-BV). General physical and mental health was measured using the Short-Form 12 (SF-12) questionnaire and the EuroQol (EQ-5D). Joint-specific function was measured using the Oxford hip or knee score. The "unstable introvert" personality type was associated with poorer pre-operative function and health in patients with hip arthrosis. In patients with knee arthrosis, there was poorer general health in those with "stable extrovert" and "unstable introvert" types. Personality was not an independent predictor of outcome following TKA or THA. The main predictor was pre-operative function and health. Comorbidity was an important covariate of both pre-operative and postoperative function. Personality may play a role in the interaction of these disease processes with function and health perception. It may also affect the response and interpretation of psychometric and patient-reported outcome measures. It may be important to characterise and identify these traits in potential arthroplasty patients as it may help deliver targeted education and management to improve outcomes in certain groups.
Magnetotransport in Artificial Kagome Spin Ice
NASA Astrophysics Data System (ADS)
Chern, Gia-Wei
2017-12-01
Magnetic nanoarrays with special geometries exhibit nontrivial collective behaviors similar to those observed in spin-ice materials. Here, we present a circuit model to describe the complex magnetotransport phenomena in artificial kagome spin ice. In this picture, the system can be viewed as a resistor network driven by voltage sources that are located at vertices of the honeycomb array. The differential voltages across different terminals of these sources are related to the ice rules that govern the local magnetization ordering. The circuit model relates the transverse Hall voltage of kagome ice to the underlying spin correlations. Treating the magnetic nanoarray as metamaterials, we present a mesoscopic constitutive equation relating the Hall resistance to magnetization components of the system. We further show that the Hall signal is significantly enhanced when the kagome ice undergoes a magnetic-charge-ordering transition. Our analysis can be readily generalized to other lattice geometries, providing a quantitative method for the design of magnetoresistance devices based on artificial spin ice.
Discovery of massive star formation quenching by non-thermal effects in the centre of NGC 1097
NASA Astrophysics Data System (ADS)
Tabatabaei, F. S.; Minguez, P.; Prieto, M. A.; Fernández-Ontiveros, J. A.
2018-01-01
Observations show that massive star formation quenches first at the centres of galaxies. To understand quenching mechanisms, we investigate the thermal and non-thermal energy balance in the central kpc of NGC 1097—a prototypical galaxy undergoing quenching—and present a systematic study of the nuclear star formation efficiency and its dependencies. This region is dominated by the non-thermal pressure from the magnetic field, cosmic rays and turbulence. A comparison of the mass-to-magnetic flux ratio of the molecular clouds shows that most of them are magnetically critical or supported against the gravitational collapse needed to form the cores of massive stars. Moreover, the star formation efficiency of the clouds drops with the magnetic field strength. Such an anti-correlation holds with neither the turbulent nor the thermal pressure. Hence, a progressive build up of the magnetic field results in high-mass stars forming inefficiently, and this may be the cause of the low-mass stellar population in the bulges of galaxies.
Searching for a Link Between Suprathermal Ions and Solar Wind Parameters During Quiet Times.
NASA Astrophysics Data System (ADS)
Nickell, J.; Desai, M. I.; Dayeh, M. A.
2017-12-01
The acceleration processes that suprathermal particles undergo are largely ambiguous. The two prevailing acceleration processes are: 1) Continuous acceleration in the IP space due to i) Bulk velocity fluctuations (e.g., Fahr et al. 2012), ii) magnetic compressions (e.g., Fisk and Gloeckler 2012), iii) magnetic field waves and turbulence (e.g., Zhang and Lee 2013), and iv) reconnection between magnetic islands (e.g., Drake et al. 2014) . 2) Discrete acceleration that occurs in discrete solar events such as CIRs, CME-driven shocks, and flares (e.g., Reames 1999, Desai et al. 2008). Using data from ACE/ULEIS during solar cycles 23 and 24 (1997-present), we examine the solar wind and magnetic field parameters during quiet-times (e.g., Dayeh et al. 2017) in an attempt to gain insights into the acceleration processes of the suprathermal particle population. In particular, we look for compression regions by performing comparative studies between solar wind and magnetic field parameters during quiet-times in the interplanetary space.
NASA Astrophysics Data System (ADS)
Hope, Kevin M.; Samudrala, Gopi K.; Vohra, Yogesh K.
2017-01-01
The atomic volume of rare earth metal dysprosium (Dy) has been measured up to high pressures of 35 GPa and low temperatures between 200 and 7 K in a diamond anvil cell using angle dispersive X-ray diffraction at a synchrotron source. The hexagonal close-packed (hcp), alpha-Samarium (α-Sm), and double hexagonal close-packed (dhcp) phases are observed to be stable in Dy under high-pressure and low-temperature conditions achieved in our experiments. Dy is known to undergo magnetic ordering below 176 K at ambient pressure with magnetic ordering Néel temperature (TN) that changes rapidly with increasing pressure. Our experimental measurement shows that Dy has near-zero thermal expansion in the magnetically ordered state and normal thermal expansion in the paramagnetic state for all the three known high pressure phases (hcp, α-Sm, and dhcp) to 35 GPa. This near-zero thermal expansion behavior in Dy is observed below the magnetic ordering temperature TN at all pressures up to 35 GPa.
Magnetic moments induce strong phonon renormalization in FeSi.
Krannich, S; Sidis, Y; Lamago, D; Heid, R; Mignot, J-M; Löhneysen, H v; Ivanov, A; Steffens, P; Keller, T; Wang, L; Goering, E; Weber, F
2015-11-27
The interactions of electronic, spin and lattice degrees of freedom in solids result in complex phase diagrams, new emergent phenomena and technical applications. While electron-phonon coupling is well understood, and interactions between spin and electronic excitations are intensely investigated, only little is known about the dynamic interactions between spin and lattice excitations. Noncentrosymmetric FeSi is known to undergo with increasing temperature a crossover from insulating to metallic behaviour with concomitant magnetic fluctuations, and exhibits strongly temperature-dependent phonon energies. Here we show by detailed inelastic neutron-scattering measurements and ab initio calculations that the phonon renormalization in FeSi is linked to its unconventional magnetic properties. Electronic states mediating conventional electron-phonon coupling are only activated in the presence of strong magnetic fluctuations. Furthermore, phonons entailing strongly varying Fe-Fe distances are damped via dynamic coupling to the temperature-induced magnetic moments, highlighting FeSi as a material with direct spin-phonon coupling and multiple interaction paths.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oz, E.; Myers, C. E.; Yamada, M.
2011-07-19
The stability properties of partial toroidal flux ropes are studied in detail in the laboratory, motivated by ubiquitous arched magnetic structures found on the solar surface. The flux ropes studied here are magnetized arc discharges formed between two electrodes in the Magnetic Reconnection Experiment (MRX) [Yamada et al., Phys. Plasmas, 4, 1936 (1997)]. The three dimensional evolution of these flux ropes is monitored by a fast visible light framing camera, while their magnetic structure is measured by a variety of internal magnetic probes. The flux ropes are consistently observed to undergo large-scale oscillations as a result of an external kinkmore » instability. Using detailed scans of the plasma current, the guide field strength, and the length of the flux rope, we show that the threshold for kink stability is governed by the Kruskal-Shafranov limit for a flux rope that is held fixed at both ends (i.e., qa = 1).« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oz, E.; Myers, C. E.; Yamada, M.
2011-10-15
The stability properties of partial-toroidal flux ropes are studied in detail in the laboratory, motivated by ubiquitous arched magnetic structures found on the solar surface. The flux ropes studied here are magnetized arc discharges formed between two electrodes in the Magnetic Reconnection Experiment (MRX) [Yamada et al., Phys. Plasmas 4, 1936 (1997)]. The three dimensional evolution of these flux ropes is monitored by a fast visible light framing camera, while their magnetic structure is measured by a variety of internal magnetic probes. The flux ropes are consistently observed to undergo large-scale oscillations as a result of an external kink instability.more » Using detailed scans of the plasma current, the guide field strength, and the length of the flux rope, we show that the threshold for kink stability is governed by the Kruskal-Shafranov limit for a flux rope that is held fixed at both ends (i.e., q{sub a} = 1).« less
Gryz, Krzysztof; Karpowicz, Jolanta
2014-01-01
Electromagnetic fields used in physiotherapeutic treatment affect not only patients, but also physiotherapists, patients not undergoing treatment and electronic medical equipment. The aim of the work was to study the parameters of the electromagnetic fields of physiotherapeutic devices with respect to requirements regarding the protection of electronic devices, including medical implants, against electromagnetic intererence, and the protection of the general public (patients not undergoing treatment and bystanders), as well as medical personnel, against the health hazards caused by electromagnetic exposure. The spatial distribution of electric and magnetic field strength was investigated near 3 capacitive short-wave and 3 long-wave diathermies and 3 ultrasound therapy units, as along with the capacitive electric currents caused by electromagnetic field interaction in the upper limbs of the physiotherapists operating these devices. The physiotherapists' exposure to electromagnetic fields depends on the spatial organisation of the workspace and their location during treatment. Electric fields able to interfere with the function of electronic medical implants and in whic anyone not undergoing treatment should not be present were measured up to 150-200 cm away from active applicators of short-wave diathermy, and up to 40-45 cm away from long-wave diathermy ones. Electric fields in which workers should not be present were measured up to 30-40 cm away from the applicators and cables of active short-wave diathermy devices. A capacitive electric current with a strength exceeding many times the international recommendations regarding workers protection was measured in the wrist while touching applicators and cables of active short-wave diathermy devices. The strongest environmental electromagnetic hazards occur near short-wave diathermy devices, and to a lesser degree near long-wave diathermy devices, but were not found near ultrasound therapy units.
Amidi, Ali; Agerbæk, Mads; Wu, Lisa M; Pedersen, Anders D; Mehlsen, Mimi; Clausen, Cecilie R; Demontis, Ditte; Børglum, Anders D; Harbøll, Anja; Zachariae, Robert
2017-06-01
Evidence suggests that testicular cancer (TC) and its treatment are associated with cognitive impairment. However, the underlying neural substrate and biological mechanisms are poorly understood. This study aimed to investigate changes in cognition and brain grey matter (GM) morphology in TC patients undergoing treatment, and to explore associations with immune markers, endocrine markers, and genotype. Sixty-five patients with stage I-III TC underwent assessment after surgery but prior to further treatment and again 6 months after. Twenty-two patients received chemotherapy (+CT), while 43 did not (-CT). Assessments included neuropsychological testing, whole-brain magnetic resonance imaging, and blood samples. Twenty-five healthy controls (HCs) underwent neuropsychological testing with a matching time interval. A regression-based approach was used to determine cognitive changes and longitudinal voxel-based morphometry (VBM) was performed to investigate changes in GM density in the TC groups. Compared with the HCs, both TC groups showed higher rates of cognitive decline (p < 0.05). A trend towards greater decline was observed in + CT (63.6 %) compared with -CT patients (39.5 %) (p = 0.07). VBM revealed widespread GM reductions in both TC groups, but a group-by-time interaction analysis revealed prefrontal reductions specific to the + CT group (p = 0.02), which were associated with poorer cognitive performance. Poorer cognitive performance was also associated with an increase in tumor necrosis factor alpha in + CT patients. Furthermore, an interaction effect was found between the APOE ε4 genotype and chemotherapy on cognitive performance with ε4 carriers performing significantly worse. These findings provide novel evidence of changes in cognition and brain morphology in TC patients undergoing treatment.
Lee, Daniel C; Markl, Michael; Dall'Armellina, Erica; Han, Yuchi; Kozerke, Sebastian; Kuehne, Titus; Nielles-Vallespin, Sonia; Messroghli, Daniel; Patel, Amit; Schaeffter, Tobias; Simonetti, Orlando; Valente, Anne Marie; Weinsaft, Jonathan W; Wright, Graham; Zimmerman, Stefan; Schulz-Menger, Jeanette
2018-01-31
The purpose of this work is to summarize cardiovascular magnetic resonance (CMR) research trends and highlights presented at the annual Society for Cardiovascular Magnetic Resonance (SCMR) scientific sessions over the past 20 years. Scientific programs from all SCMR Annual Scientific Sessions from 1998 to 2017 were obtained. SCMR Headquarters also provided data for the number and the country of origin of attendees and the number of accepted abstracts according to type. Data analysis included text analysis (key word extraction) and visualization by 'word clouds' representing the most frequently used words in session titles for 5-year intervals. In addition, session titles were sorted into 17 major subject categories to further evaluate research and clinical CMR trends over time. Analysis of SCMR annual scientific sessions locations, attendance, and number of accepted abstracts demonstrated substantial growth of CMR research and clinical applications. As an international field of study, significant growth of CMR was documented by a strong increase in SCMR scientific session attendance (> 500%, 270 to 1406 from 1998 to 2017, number of accepted abstracts (> 700%, 98 to 701 from 1998 to 2018) and number of international participants (42-415% increase for participants from Asia, Central and South America, Middle East and Africa in 2004-2017). 'Word clouds' based evaluation of research trends illustrated a shift from early focus on 'MRI technique feasibility' to new established techniques (e.g. late gadolinium enhancement) and their clinical applications and translation (key words 'patient', 'disease') and more recently novel techniques and quantitative CMR imaging (key words 'mapping', 'T1', 'flow', 'function'). Nearly every topic category demonstrated an increase in the number of sessions over the 20-year period with 'Clinical Practice' leading all categories. Our analysis identified three growth areas 'Congenital', 'Clinical Practice', and 'Structure/function/flow'. The analysis of the SCMR historical archives demonstrates a healthy and internationally active field of study which continues to undergo substantial growth and expansion into new and emerging CMR topics and clinical application areas.
NASA Astrophysics Data System (ADS)
Farhang, Nastaran; Safari, Hossein; Wheatland, Michael S.
2018-05-01
Solar flares are an abrupt release of magnetic energy in the Sun’s atmosphere due to reconnection of the coronal magnetic field. This occurs in response to turbulent flows at the photosphere that twist the coronal field. Similar to earthquakes, solar flares represent the behavior of a complex system, and expectedly their energy distribution follows a power law. We present a statistical model based on the principle of minimum energy in a coronal loop undergoing magnetic reconnection, which is described as an avalanche process. We show that the distribution of peaks for the flaring events in this self-organized critical system is scale-free. The obtained power-law index of 1.84 ± 0.02 for the peaks is in good agreement with satellite observations of soft X-ray flares. The principle of minimum energy can be applied for general avalanche models to describe many other phenomena.
Magnetized hypermassive neutron-star collapse: a central engine for short gamma-ray bursts.
Shibata, Masaru; Duez, Matthew D; Liu, Yuk Tung; Shapiro, Stuart L; Stephens, Branson C
2006-01-27
A hypermassive neutron star (HMNS) is a possible transient formed after the merger of a neutron-star binary. In the latest axisymmetric magnetohydrodynamic simulations in full general relativity, we find that a magnetized HMNS undergoes "delayed" collapse to a rotating black hole (BH) as a result of angular momentum transport via magnetic braking and the magnetorotational instability. The outcome is a BH surrounded by a massive, hot torus with a collimated magnetic field. The torus accretes onto the BH at a quasisteady accretion rate [FORMULA: SEE TEXT]; the lifetime of the torus is approximately 10 ms. The torus has a temperature [FORMULA: SEE TEXT], leading to copious ([FORMULA: SEE TEXT]) thermal radiation that could trigger a fireball. Therefore, the collapse of a HMNS is a promising scenario for generating short-duration gamma-ray bursts and an accompanying burst of gravitational waves and neutrinos.
Kondo behavior and metamagnetic phase transition in the heavy-fermion compound CeBi2
NASA Astrophysics Data System (ADS)
Zhou, W.; Xu, C. Q.; Li, B.; Sankar, R.; Zhang, F. M.; Qian, B.; Cao, C.; Dai, J. H.; Lu, Jianming; Jiang, W. X.; Qian, Dong; Xu, Xiaofeng
2018-05-01
Heavy fermions represent an archetypal example of strongly correlated electron systems which, due to entanglement among different interactions, often exhibit exotic and fascinating physics involving Kondo screening, magnetism, and unconventional superconductivity. Here we report a comprehensive study on the transport and thermodynamic properties of a cerium-based heavy-fermion compound CeBi2 which undergoes an antiferromagnetic transition at TN˜3.3 K . Its high-temperature paramagnetic state is characterized by an enhanced heat capacity with Sommerfeld coefficient γ over 200 mJ mol-1K-2 . The magnetization in the magnetically ordered state features a metamagnetic transition. Remarkably, a large negative magnetoresistance associated with the magnetism was observed in a wide temperature and field-angle range. Collectively, CeBi2 may serve as an intriguing system to study the interplay between the f electrons and the itinerant Fermi sea.
Relating magnetic reconnection to coronal heating
Longcope, D. W.; Tarr, L. A.
2015-01-01
It is clear that the solar corona is being heated and that coronal magnetic fields undergo reconnection all the time. Here we attempt to show that these two facts are related—i.e. coronal reconnection generates heat. This attempt must address the fact that topological change of field lines does not automatically generate heat. We present one case of flux emergence where we have measured the rate of coronal magnetic reconnection and the rate of energy dissipation in the corona. The ratio of these two, , is a current comparable to the amount of current expected to flow along the boundary separating the emerged flux from the pre-existing flux overlying it. We can generalize this relation to the overall corona in quiet Sun or in active regions. Doing so yields estimates for the contribution to coronal heating from magnetic reconnection. These estimated rates are comparable to the amount required to maintain the corona at its observed temperature. PMID:25897089
NASA Technical Reports Server (NTRS)
Horwath, T. G.
1992-01-01
The propagation of vibrational energy in bulk, torsional, and flexural modes, in electrically conducting media can undergo strong attenuation if subjected to high magnetic fields in certain spatial arrangements. The reasons for this are induced Eddy currents which are generated by the volume elements in the media moving transversally to the magnetic field at acoustic velocities. In magnetic fields achievable with superconductors, the non-conservative (dissipative) forces are compared to the elastic and inertial forces for most metals. Strong dissipation of vibrational energy in the form of heat takes place as a result. A simplified theory is presented based on engineering representations of electrodynamics, attenuation values for representative metals are calculated, and problems encountered in formulating a generalized theory based on electrodynamics of moving media are discussed. General applications as well as applications specific to maglev are discussed.
I Am The One And Only: Regular Magnetic Field In The Igm Of The Stepan'S Quintet
NASA Astrophysics Data System (ADS)
Nikiel-Wroczyński, Błażej
2017-10-01
Ordered magnetic fields are generally believed not to exist in the intergalactic space of galaxy groups; on the one hand, it is known that groups undergo violent interactions that could easily dirupt the delicate fabric of a non-turbulent field, on the other hand - it was never said that survival of such a field is an impossible occurence. The most well-known galaxy group, the Stephan's Quintet, once again turns to be an amazing object, this time in regards to the matter of the existence of a regular magnetic field. Our new study, done with the high fidelity WSRT data, shows strong hints that non-negligible field is present in the volume inhabited by the Quintet, and it is a large-scale, strong, and regular one. As for the moment, no other group was found to host similar magnetic fields, as the Quintet hosts.
2014-08-04
A photograph showing what all four Magnetospheric Multiscale (MMS) spacecraft look like when stacked is seen taped to the window of a Naval Research Laboratory cleanroom where one of the four spacecraft is undergoing testing, Monday, August 4, 2014, in Washington. The Magnetospheric Multiscale, or MMS, mission will study the mystery of how magnetic fields around Earth connect and disconnect, explosively releasing energy via a process known as magnetic reconnection. The four identical spacecraft are scheduled to launch in 2015 from Cape Canaveral and will orbit around Earth in varying formations through the dynamic magnetic system surrounding our planet to provide the first three-dimensional views of the magnetic reconnection process. The goal of the STP Program is to understand the fundamental physical processes of the space environment from the sun to Earth, other planets, and the extremes of the solar system boundary. Photo Credit: (NASA/Bill Ingalls)
2014-08-04
NASA Administrator Charles Bolden listens to Magnetospheric Multiscale (MMS) Mission Project Manager Craig Tooley talk about the MMS mission outside of a Naval Research Laboratory cleanroom where one of four Magnetospheric Multiscale (MMS) spacecraft is currently undergoing testing, Monday, August 4, 2014, in Washington. The Magnetospheric Multiscale, or MMS, mission will study the mystery of how magnetic fields around Earth connect and disconnect, explosively releasing energy via a process known as magnetic reconnection. The four identical spacecraft are scheduled to launch in 2015 from Cape Canaveral and will orbit around Earth in varying formations through the dynamic magnetic system surrounding our planet to provide the first three-dimensional views of the magnetic reconnection process. The goal of the STP Program is to understand the fundamental physical processes of the space environment from the sun to Earth, other planets, and the extremes of the solar system boundary. Photo Credit: (NASA/Bill Ingalls)
Fluctuations and All-In-All-Out Ordering in Dipole-Octupole Nd2Zr2O7
NASA Astrophysics Data System (ADS)
Lhotel, E.; Petit, S.; Guitteny, S.; Florea, O.; Ciomaga Hatnean, M.; Colin, C.; Ressouche, E.; Lees, M. R.; Balakrishnan, G.
2015-11-01
By means of neutron scattering and magnetization measurements down to 90 mK, we determine the magnetic ground state of the spin-ice candidate Nd2Zr2O7. We show that, despite ferromagnetic interactions, Nd2Zr2O7 undergoes a transition around 285 mK towards an all-in-all-out antiferromagnetic state, with a strongly reduced ordered magnetic moment. We establish the (H ,T ) phase diagram in the three directions of the applied field and reveal a metamagnetic transition around 0.1 T, associated with an unexpected shape of the magnetization curves. We propose that this behavior results from the peculiar nature of the Nd3 + doublet, a dipolar-octupolar doublet, different from the standard Kramers doublet studied to date, thus revealing the importance of multipolar correlations in the properties of pyrochlore oxides.
The impact of functional imaging on radiation medicine.
Sharma, Nidhi; Neumann, Donald; Macklis, Roger
2008-09-15
Radiation medicine has previously utilized planning methods based primarily on anatomic and volumetric imaging technologies such as CT (Computerized Tomography), ultrasound, and MRI (Magnetic Resonance Imaging). In recent years, it has become apparent that a new dimension of non-invasive imaging studies may hold great promise for expanding the utility and effectiveness of the treatment planning process. Functional imaging such as PET (Positron Emission Tomography) studies and other nuclear medicine based assays are beginning to occupy a larger place in the oncology imaging world. Unlike the previously mentioned anatomic imaging methodologies, functional imaging allows differentiation between metabolically dead and dying cells and those which are actively metabolizing. The ability of functional imaging to reproducibly select viable and active cell populations in a non-invasive manner is now undergoing validation for many types of tumor cells. Many histologic subtypes appear amenable to this approach, with impressive sensitivity and selectivity reported. For clinical radiation medicine, the ability to differentiate between different levels and types of metabolic activity allows the possibility of risk based focal treatments in which the radiation doses and fields are more tightly connected to the perceived risk of recurrence or progression at each location. This review will summarize many of the basic principles involved in the field of functional PET imaging for radiation oncology planning and describe some of the major relevant published data behind this expanding trend.
Illness Denial in Schizophrenia Spectrum Disorders: A Function of Left Hemisphere Dominance
Gerretsen, Philip; Menon, Mahesh; Chakravarty, M. Mallar; Lerch, Jason P; Mamo, David C.; Remington, Gary; Pollock, Bruce G; Graff-Guerrero, Ariel
2014-01-01
Impaired illness awareness or anosognosia is a common, but poorly understood feature of schizophrenia that contributes to medication nonadherence and poor treatment outcomes. Here we present a functional imaging study to measure brain activity at the moment of illness denial. To accomplish this, participants with schizophrenia (n = 18) with varying degrees of illness awareness were confronted with their illness beliefs while undergoing functional MRI. To link structure with function, we explored the relationships among impaired illness awareness and brain activity during the illness denial task with cortical thickness (CT). Impaired illness awareness was associated with increased brain activity in the left temporoparietooccipital junction (TPO) and left medial prefrontal cortex (mPFC) at the moment of illness denial. Brain activity in the left mPFC appeared to be a function of participants’ degree of self-reflectiveness, while the activity in the left TPO was associated with cortical thinning in this region and more specific to illness denial. Participants with impaired illness awareness had slower response times to illness related stimuli than those with good illness awareness. Increased left hemisphere brain activity in association with illness denial is consistent with the literature in other neuropsychiatric conditions attributing anosognosia or impaired illness awareness to left hemisphere dominance. The TPO and mPFC may represent putative targets for non-invasive treatment interventions, such as transcranial magnetic or direct current stimulation. PMID:25209949
Spectral Properties of Suprathermal Heavy Ions in Corotating Interaction Regions at 1 AU
NASA Astrophysics Data System (ADS)
Filwett, R. J.; Desai, M. I.; Ebert, R. W.; Dayeh, M. A.
2017-12-01
Suprathermal particles are an important constituent of the seed population that is accelerated in interplanetary events. Despite their importance, the origin of these particles and the acceleration mechanism they undergo is poorly understood. Using data from Wind/EPACT/STEP and ACE/ULEIS we examined the 0.03-3.0MeV nucleon-1 H-Fe spectra in 41 corotating interaction regions (CIRs). We fit power-law functions to the data to obtain the spectral index γ and break energy Eo. We examined the energy and species-to-species variation of both γ and Eo. Our results show Eo decreases systematically with decreasing Q/M scaling as (Q/M)α. Additionally, we compared the expected compression ratio, H, as determined by γ, to the observed magnetic and density compression ratios. We discuss these results and their implications to local vs. non-local suprathermal particle acceleration and transport in CIRs.
The maternal brain and its plasticity in humans
Kim, Pilyoung; Strathearn, Lane; Swain, James E.
2015-01-01
Early mother-infant relationships play important roles in infants’ optimal development. New mothers undergo neurobiological changes that support developing mother-infant relationships regardless of great individual differences in those relationships. In this article, we review the neural plasticity in human mothers’ brains based on functional magnetic resonance imaging (fMRI) studies. First, we review the neural circuits that are involved in establishing and maintaining mother-infant relationships. Second, we discuss early postpartum factors (e.g., birth and feeding methods, hormones, and parental sensitivity) that are associated with individual differences in maternal brain neuroplasticity. Third, we discuss abnormal changes in the maternal brain related to psychopathology (i.e., postpartum depression, posttraumatic stress disorder, substance abuse) and potential brain remodeling associated with interventions. Last, we highlight potentially important future research directions to better understand normative changes in the maternal brain and risks for abnormal changes that may disrupt early mother-infant relationships. PMID:26268151
Arora, Saurabh; Agarwal, Krishan Kant; Karunanithi, Sellam; Tripathi, Madhavi; Kumar, Rakesh
2014-01-01
Pheochromocytomas are rare catecholamine-secreting tumors derived from the sympathetic nervous system. The most common sites of metastasis for pheochromocytoma or extra-adrenal paraganglioma are lymph nodes, bones, lungs, and liver. Patients with known or suspected malignancy should undergo staging with computed tomography (CT) or magnetic resonance imaging as well as functional imaging (e.g. with 123I/131I-MIBG (131I-metaiodobenzylguanidine) and 68Ga-DOTANOC (68Ga-labeled [1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid]-1-NaI3-octreotide) positron emission tomography (PET)/CT) to determine the extent and location of disease. We present a case of recurrent malignant pheochromocytoma with unusual site of metastasis in omentum, which was positive on 68Ga-DOTANOC PET/CT and 131I-MIBG single-photon emission computed tomography (SPECT/)/CT scintigraphy. PMID:25400380
Arora, Saurabh; Agarwal, Krishan Kant; Karunanithi, Sellam; Tripathi, Madhavi; Kumar, Rakesh
2014-10-01
Pheochromocytomas are rare catecholamine-secreting tumors derived from the sympathetic nervous system. The most common sites of metastasis for pheochromocytoma or extra-adrenal paraganglioma are lymph nodes, bones, lungs, and liver. Patients with known or suspected malignancy should undergo staging with computed tomography (CT) or magnetic resonance imaging as well as functional imaging (e.g. with (123)I/(131)I-MIBG ((131)I-metaiodobenzylguanidine) and (68)Ga-DOTANOC ((68)Ga-labeled [1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid]-1-NaI3-octreotide) positron emission tomography (PET)/CT) to determine the extent and location of disease. We present a case of recurrent malignant pheochromocytoma with unusual site of metastasis in omentum, which was positive on (68)Ga-DOTANOC PET/CT and (131)I-MIBG single-photon emission computed tomography (SPECT/)/CT scintigraphy.
Bio-inspired self-shaping ceramics
Bargardi, Fabio L.; Le Ferrand, Hortense; Libanori, Rafael; Studart, André R.
2016-01-01
Shaping ceramics into complex and intricate geometries using cost-effective processes is desirable in many applications but still remains an open challenge. Inspired by plant seed dispersal units that self-fold on differential swelling, we demonstrate that self-shaping can be implemented in ceramics by programming the material's microstructure to undergo local anisotropic shrinkage during heat treatment. Such microstructural design is achieved by magnetically aligning functionalized ceramic platelets in a liquid ceramic suspension, subsequently consolidated through an established enzyme-catalysed reaction. By fabricating alumina compacts exhibiting bio-inspired bilayer architectures, we achieve deliberate control over shape change during the sintering step. Bending, twisting or combinations of these two basic movements can be successfully programmed to obtain a myriad of complex shapes. The simplicity and the universality of such a bottom-up shaping method makes it attractive for applications that would benefit from low-waste ceramic fabrication, temperature-resistant interlocking structures or unusual geometries not accessible using conventional top–down manufacturing. PMID:28008930
Bio-inspired self-shaping ceramics
NASA Astrophysics Data System (ADS)
Bargardi, Fabio L.; Le Ferrand, Hortense; Libanori, Rafael; Studart, André R.
2016-12-01
Shaping ceramics into complex and intricate geometries using cost-effective processes is desirable in many applications but still remains an open challenge. Inspired by plant seed dispersal units that self-fold on differential swelling, we demonstrate that self-shaping can be implemented in ceramics by programming the material's microstructure to undergo local anisotropic shrinkage during heat treatment. Such microstructural design is achieved by magnetically aligning functionalized ceramic platelets in a liquid ceramic suspension, subsequently consolidated through an established enzyme-catalysed reaction. By fabricating alumina compacts exhibiting bio-inspired bilayer architectures, we achieve deliberate control over shape change during the sintering step. Bending, twisting or combinations of these two basic movements can be successfully programmed to obtain a myriad of complex shapes. The simplicity and the universality of such a bottom-up shaping method makes it attractive for applications that would benefit from low-waste ceramic fabrication, temperature-resistant interlocking structures or unusual geometries not accessible using conventional top-down manufacturing.
Peer Influence Via Instagram: Effects on Brain and Behavior in Adolescence and Young Adulthood.
Sherman, Lauren E; Greenfield, Patricia M; Hernandez, Leanna M; Dapretto, Mirella
2018-01-01
Mobile social media often feature the ability to "Like" content posted by others. This study examined the effect of Likes on youths' neural and behavioral responses to photographs. High school and college students (N = 61, ages 13-21) viewed theirs and others' Instagram photographs while undergoing functional Magnetic Resonance Imaging (fMRI). Participants more often Liked photographs that appeared to have received many (vs. few) Likes. Popular photographs elicited greater activity in multiple brain regions, including the nucleus accumbens (NAcc), a hub of the brain's reward circuitry. NAcc responsivity increased with age for high school but not college students. When viewing images depicting risk-taking (vs. nonrisky photographs), high school students, but not college students, showed decreased activation of neural regions implicated in cognitive control. © 2017 The Authors. Child Development © 2017 Society for Research in Child Development, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gabuda, S. P.; Kozlova, S. G.; Novosibirsk State University, 2, Pirogova Str., Novosibirsk 630090
We report an abnormal difference of low-temperature mobility of left-twisted and right-twisted conformations of roto symmetric molecules C{sub 6}H{sub 12}N{sub 2} (dabco) located in the same positions in crystal Zn{sub 2}(C{sub 8}H{sub 4}O{sub 4}){sub 2}⋅C{sub 6}H{sub 12}N{sub 2}. The difference between {sup 1}H NMR (Nuclear Magnetic Resonance) spin-relaxation data for left-twisted and right-twisted molecules reaches ∼3 × 10{sup 3} times at 8 K and tends to grow at lower temperatures. We argue that taking into account four-component relativistic Dirac wave functions in the vicinity of the nodal plane of dabco molecules and vacuum fluctuations due to virtual particle-antiparticle pairs canmore » explain the changes which C{sub 6}H{sub 12}N{sub 2} conformations undergo at low temperatures.« less
Physiology of the motor cortex in polio survivors.
Lupu, Vitalie D; Danielian, Laura; Johnsen, Jacqueline A; Vasconcelos, Olavo M; Prokhorenko, Olga A; Jabbari, Bahman; Campbell, William W; Floeter, Mary Kay
2008-02-01
We hypothesized that the corticospinal system undergoes functional changes in long-term polio survivors. Central motor conduction times (CMCTs) to the four limbs were measured in 24 polio survivors using transcranial magnetic stimulation (TMS). Resting motor thresholds and CMCTs were normal. In 17 subjects whose legs were affected by polio and 13 healthy controls, single- and paired-pulse TMS was used to assess motor cortex excitability while recording from tibialis anterior (TA) muscles at rest and following maximal contraction until fatigue. In polio survivors the slope of the recruitment curve was normal, but maximal motor evoked potentials (MEPs) were larger than in controls. MEPs were depressed after fatiguing exercise. Three patients with central fatigue by twitch interpolation had a trend toward slower recovery. There was no association with symptoms of post-polio syndrome. These changes occurring after polio may allow the motor cortex to activate a greater proportion of the motor neurons innervating affected muscles.
Using Proton Magnetic Resonance Imaging and Spectroscopy to Understand Brain "Activation"
ERIC Educational Resources Information Center
Baslow, Morris H.; Guilfoyle, David N.
2007-01-01
Upon stimulation, areas of the brain associated with specific cognitive processing tasks may undergo observable physiological changes, and measures of such changes have been used to create brain maps for visualization of stimulated areas in task-related brain "activation" studies. These perturbations usually continue throughout the period of the…
A Short History of Three Chemical Shifts
ERIC Educational Resources Information Center
Nagaoka, Shin-ichi
2007-01-01
A short history of chemical shifts in nuclear magnetic resonance (NMR), electron spectroscopy for chemical analysis (ESCA) and Mossbauer spectroscopy, which are useful for chemical studies, is described. The term chemical shift is shown to have originated in the mistaken assumption that nuclei of a given element would all undergo resonance at the…
Liquid-explosives scanners stand trial in airports
DOE Office of Scientific and Technical Information (OSTI.GOV)
Matthews, Jermey N. A.
Air passengers may once more be allowed to pack beverages, lotions, and hair spray in their carry-on luggage, if imaging technologies to detect liquid explosives can prove their worth. Several competing systems, including multi-energy x-ray systems and a low-field magnetic resonance imaging (MRI) scanner, are undergoing field tests at some airports worldwide.
Filling the holes in the CaFe4As3 structure: Synthesis and magnetism of CaCo5As3
NASA Astrophysics Data System (ADS)
Rosa, P. F. S.; Scott, B. L.; Ronning, F.; Bauer, E. D.; Thompson, J. D.
2017-07-01
Here, we investigate single crystals of CaCo5As3 by means of single-crystal x-ray diffraction, microprobe, magnetic susceptibility, heat capacity, and pressure-dependent transport measurements. CaCo5As3 shares the same structure of CaFe4As3 with an additional Co atom filling a lattice vacancy and undergoes a magnetic transition at TM=16 K associated with a frustrated magnetic order. CaCo5As3 displays metallic behavior and its Sommerfeld coefficient (γ =70 mJ/mol K2) indicates a moderate enhancement of electron-electron correlations. Transport data under pressures to 2.5 GPa reveal a suppression of TM at a rate of -0.008 K/GPa. First-principles electronic structure calculations show a complex three-dimensional band structure and magnetic moments that depend on the local environment at each Co site. Our results are compared with previous data on CaFe4As3 and provide a scenario for a magnetically frustrated ground state in this family of compounds.
NASA Astrophysics Data System (ADS)
Dung, Nguyen Thi; Linh, Dinh Chi; Huyen Yen, Pham Duc; Yu, Seong Cho; Van Dang, Nguyen; Dang Thanh, Tran
2018-06-01
Influence of the crystallite size on the magnetic and critical properties of nanocrystals has been investigated. The results show that Curie temperature and magnetization slightly decrease with decreasing average crystallite size . Based on the mean-field theory and the magnetic-field dependences of magnetization at different temperatures , we pointed out that the ferromagnetic-paramagnetic phase transition in the samples undergoes the second-order phase transition with the critical exponents (, , and ) close to those of the mean-field theory. However, there is a small deviation from those expected for the mean-field theory of the values of , and obtained for the samples. It means that short-range ferromagnetic interactions appear in the smaller particles. In other words, nanocrystals become more magnetically inhomogeneous with smaller crystallite sizes that could be explained by the presence of surface-related effects, lattice strain and distortions, which lead the strength of ferromagnetic interaction is decreased in the small crystallite sizes.
Pakhira, Santanu; Mazumdar, Chandan; Choudhury, Dibyasree; Ranganathan, R; Giri, S
2018-05-16
In this work, we report the successful synthesis of a new intermetallic compound Dy2Ni0.87Si2.95 forming in single phase only with a chemically disordered structure. The random distribution of Ni/Si and crystal defects create a variation in the local electronic environment between the magnetic Dy ions. In the presence of both disorder and competing exchange interactions driven magnetic frustration, originating due to c/a ∼ 1, the compound undergoes spin freezing behaviour below 5.6 K. In the non-equilibrium state below the spin freezing behaviour, the compound exhibits aging phenomena and magnetic memory effects. In the magnetically short-range ordered region, much above the freezing temperature, an unusual occurrence of considerable magnetic entropy change, -ΔSmaxM ∼ 21 J kg-1 K-1 with large cooling power RCP ∼ 531 J kg-1 and adiabatic temperature change, ΔTad ∼ 10 K for a field change of 70 kOe, is observed for this short range ordered cluster-glass compound without any magnetic hysteresis loss.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sanjeewa, Liurukara D.; Garlea, Vasile O.; McGuire, Michael A.
The structural and magnetic properties of a glaserite-type Na 2BaFe(VO 4) 2 compound, featuring a triangular magnetic lattice of Fe 2+ (S = 2), are reported. Temperature dependent X-ray single crystal studies indicate that at room temperature the system adopts a trigonal Pmore » $$\\bar{3}$$ m1 structure and undergoes a structural phase transition to a C2/c monoclinic phase slightly below room temperature (T s = 288 K). This structural transition involves a tilting of Fe–O–V bond angles and strongly influences the magnetic correlation within the Fe triangular lattice. The magnetic susceptibility measurements reveal a ferromagnetic transition near 7 K. Single crystal neutron diffraction confirms the structural distortion and the ferromagnetic spin ordering in Na 2BaFe(VO 4) 2. The magnetic structure of the ordered state is modeled in the magnetic space group C2'/c' that implies a ferromagnetic order of the a and c moment components and antiferromagnetic arrangement for the b components. Altogether, the Fe magnetic moments form ferromagnetic layers that are stacked along the c-axis, where the spins point along one of the (111) facets of the FeO 6 octahedron.« less
Sanjeewa, Liurukara D.; Garlea, Vasile O.; McGuire, Michael A.; ...
2017-12-07
The structural and magnetic properties of a glaserite-type Na 2BaFe(VO 4) 2 compound, featuring a triangular magnetic lattice of Fe 2+ (S = 2), are reported. Temperature dependent X-ray single crystal studies indicate that at room temperature the system adopts a trigonal Pmore » $$\\bar{3}$$ m1 structure and undergoes a structural phase transition to a C2/c monoclinic phase slightly below room temperature (T s = 288 K). This structural transition involves a tilting of Fe–O–V bond angles and strongly influences the magnetic correlation within the Fe triangular lattice. The magnetic susceptibility measurements reveal a ferromagnetic transition near 7 K. Single crystal neutron diffraction confirms the structural distortion and the ferromagnetic spin ordering in Na 2BaFe(VO 4) 2. The magnetic structure of the ordered state is modeled in the magnetic space group C2'/c' that implies a ferromagnetic order of the a and c moment components and antiferromagnetic arrangement for the b components. Altogether, the Fe magnetic moments form ferromagnetic layers that are stacked along the c-axis, where the spins point along one of the (111) facets of the FeO 6 octahedron.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Guoxing; Cheng, Zhenxiang, E-mail: jianli@uow.edu.au, E-mail: cheng@uow.edu.au; Fang, Chunsheng
Structural and magnetic properties in TbMn{sub 2}Si{sub 2} are studied by variable temperature X-ray diffraction, magnetization, electrical resistivity, and heat capacity measurements. TbMn{sub 2}Si{sub 2} undergoes two successive magnetic transitions at around T{sub c1} = 50 K and T{sub c2} = 64 K. T{sub c1} remains almost constant with increasing magnetic field, but T{sub c2} shifts significantly to higher temperature. Thus, there are two partially overlapping peaks in the temperature dependence of magnetic entropy change, i.e., −ΔS{sub M} (T). The different responses of T{sub c1} and T{sub c2} to external magnetic field, and the overlapping of −ΔS{sub M} (T) around T{sub c1} and T{sub c2} inducemore » a large refrigerant capacity (RC) within a large temperature range. The large reversible magnetocaloric effect (−ΔS{sub M}{sup peak} ∼ 16 J/kg K for a field change of 0–5 T) and RC (=396 J/kg) indicate that TbMn{sub 2}Si{sub 2} could be a promising candidate for low temperature magnetic refrigeration.« less
Structural and magnetic phase transitions in CeCu 6-xT x (T = Ag,Pd)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Poudel, Lekhanath N.; De la cruz, Clarina; Payzant, E. Andrew
The structural and the magnetic properties of CeCu 6-xAg x (0 ≤ x ≤ 0.85) and CeCu 6-xPd x (0 ≤ x ≤ 0.4) have been studied using neutron diffraction, resonant ultrasound spectroscopy (RUS), x-ray diffraction measurements, and first principles calculations. The structural and magnetic phase diagrams of CeCu 6-xAg x and CeCu 6-xPd x as a function of Ag/Pd composition are reported. The end member, CeCu 6, undergoes a structural phase transition from an orthorhombic ( Pnma) to a monoclinic (P2 1/c) phase at 240 K. In CeCu 6-xAg x, the structural phase transition temperature (T s) decreases linearlymore » with Ag concentration and extrapolates to zero at x S ≈ 0.1. The structural transition in CeCu 6-xPd x remains unperturbed with Pd substitution within the range of our study. The lattice constant b slightly decreases with Ag/Pd doping, whereas a and c increase with an overall increase in the unit cell volume. Both systems, CeCu 6-xAg x and CeCu 6-xPd x, exhibit a magnetic quantum critical point (QCP), at x ≈ 0.2 and x ≈ 0.05, respectively. Near the QCP, long range antiferromagnetic ordering takes place at an incommensurate wave vector (δ 1 0 δ 2), where δ 1 ~ 0.62, δ 2 ~ 0.25, x = 0.125 for CeCu 6-xPd x and δ 1 ~ 0.64, δ 2 ~ 0.3, x = 0.3 for CeCu 6-xAg x. As a result, the magnetic structure consists of an amplitude modulation of the Ce moments which are aligned along the c axis of the orthorhombic unit cell.« less
Structural and magnetic phase transitions in CeCu 6-xT x (T = Ag,Pd)
Poudel, Lekhanath N.; De la cruz, Clarina; Payzant, E. Andrew; ...
2015-12-15
The structural and the magnetic properties of CeCu 6-xAg x (0 ≤ x ≤ 0.85) and CeCu 6-xPd x (0 ≤ x ≤ 0.4) have been studied using neutron diffraction, resonant ultrasound spectroscopy (RUS), x-ray diffraction measurements, and first principles calculations. The structural and magnetic phase diagrams of CeCu 6-xAg x and CeCu 6-xPd x as a function of Ag/Pd composition are reported. The end member, CeCu 6, undergoes a structural phase transition from an orthorhombic ( Pnma) to a monoclinic (P2 1/c) phase at 240 K. In CeCu 6-xAg x, the structural phase transition temperature (T s) decreases linearlymore » with Ag concentration and extrapolates to zero at x S ≈ 0.1. The structural transition in CeCu 6-xPd x remains unperturbed with Pd substitution within the range of our study. The lattice constant b slightly decreases with Ag/Pd doping, whereas a and c increase with an overall increase in the unit cell volume. Both systems, CeCu 6-xAg x and CeCu 6-xPd x, exhibit a magnetic quantum critical point (QCP), at x ≈ 0.2 and x ≈ 0.05, respectively. Near the QCP, long range antiferromagnetic ordering takes place at an incommensurate wave vector (δ 1 0 δ 2), where δ 1 ~ 0.62, δ 2 ~ 0.25, x = 0.125 for CeCu 6-xPd x and δ 1 ~ 0.64, δ 2 ~ 0.3, x = 0.3 for CeCu 6-xAg x. As a result, the magnetic structure consists of an amplitude modulation of the Ce moments which are aligned along the c axis of the orthorhombic unit cell.« less
Odaka, Mizuho; Minakata, Kenji; Toyokuni, Hideaki; Yamazaki, Kazuhiro; Yonezawa, Atsushi; Sakata, Ryuzo; Matsubara, Kazuo
2015-08-01
This study aimed to develop and assess the effectiveness of a protocol for antibiotic prophylaxis based on preoperative kidney function in patients undergoing open heart surgery. We established a protocol for antibiotic prophylaxis based on preoperative kidney function in patients undergoing open heart surgery. This novel protocol was assessed by comparing patients undergoing open heart surgery before (control group; n = 30) and after its implementation (protocol group; n = 31) at Kyoto University Hospital between July 2012 and January 2013. Surgical site infections (SSIs) were observed in 4 control group patients (13.3 %), whereas no SSIs were observed in the protocol group patients (P < 0.05). The total duration of antibiotic use decreased significantly from 80.7 ± 17.6 h (mean ± SD) in the control group to 55.5 ± 14.9 h in the protocol group (P < 0.05). Similarly, introduction of the protocol significantly decreased the total antibiotic dose used in the perioperative period (P < 0.05). Furthermore, antibiotic regimens were changed under suspicion of infection in 5 of 30 control group patients, whereas none of the protocol group patients required this additional change in the antibiotic regimen (P < 0.05). Our novel antibiotic prophylaxis protocol based on preoperative kidney function effectively prevents SSIs in patients undergoing open heart surgery.
McClain, Craig D; Landrigan-Ossar, Mary
2014-03-01
This article gives a review of 3 challenges in caring for children undergoing neurosurgical and neurointerventional procedures. Anesthesiologists may have experience with certain aspects of these situations but may not have extensive experience with each clinical setting. This review addresses issues with awake craniotomy, intraoperative magnetic resonance imaging, and neurointerventional procedures in children with neurologic disease. Familiarization with these complex clinical scenarios and their unique considerations allows the anesthesiologist to deliver optimal care and helps facilitate the best possible outcome for these patients. Copyright © 2014 Elsevier Inc. All rights reserved.
Magnetic resonance imaging of convection in laser-polarized xenon
NASA Technical Reports Server (NTRS)
Mair, R. W.; Tseng, C. H.; Wong, G. P.; Cory, D. G.; Walsworth, R. L.
2000-01-01
We demonstrate nuclear magnetic resonance (NMR) imaging of the flow and diffusion of laser-polarized xenon (129Xe) gas undergoing convection above evaporating laser-polarized liquid xenon. The large xenon NMR signal provided by the laser-polarization technique allows more rapid imaging than one can achieve with thermally polarized gas-liquid systems, permitting shorter time-scale events such as rapid gas flow and gas-liquid dynamics to be observed. Two-dimensional velocity-encoded imaging shows convective gas flow above the evaporating liquid xenon, and also permits the measurement of enhanced gas diffusion near regions of large velocity variation.
Magnetic and structural instabilities in CePd 2Al 2 and LaPd 2Al 2
NASA Astrophysics Data System (ADS)
Chapon, L. C.; Goremychkin, E. A.; Osborn, R.; Rainford, B. D.; Short, S.
2006-05-01
We have investigated the crystal and magnetic structure of the RPd 2Al 2 compounds (R=La, Ce) by neutron powder diffraction (ND) and inelastic neutron scattering (INS). The ND study shows that both compounds undergo a structural phase transition from tetragonal to orthorhombic symmetry at 91.5 K (La) and 13.5 K (Ce). In the case of CePd 2Al 2 the crystal field excitation spectrum, which has an extra peak that cannot be explained by a standard crystal field model, indicates the presence of strong magneto-elastic coupling.
Fabrication of thin bulk ceramics for microwave circulator applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ings, J.B.; Simmins, J.J.; May, J.L.
1995-09-01
Planer MMIC circulator applications require the production of thin, flat garnet, spinel, and hexagonal ferrite circulator elements. Fabrication of cira 250 {mu}m circulator elements was done by tape casting and roll compaction. For the garnet, tape cast gave equivalent results to roll compaction. For the spinel and hexaferrite materials, which undergo magnetic flocculation, roll compaction was found to be the preferred fabrication method. Roll compacted lithium ferrite resulted in higher densities and lower {triangle}H and tan{delta} than did the tape case material. Roll compacted barium hexaferrite resulted in higher densities and remanent magnetization than did the tape cast material.
On non-linear magnetic-charged black hole surrounded by quintessence
NASA Astrophysics Data System (ADS)
Nam, Cao H.
2018-06-01
We derive a non-linear magnetic-charged black hole surrounded by quintessence, which behaves asymptotically like the Schwarzschild black hole surrounded by quintessence but at the short distances like the dS geometry. The horizon properties of this black hole are investigated in detail. The thermodynamics of the black hole is studied in the local and global views. Finally, by calculating the heat capacity and the free energy, we point to that the black hole may undergo a thermal phase transition, between a larger unstable black hole and a smaller stable black hole, at a critical temperature.
Fogel, Mark A; Li, Christine; Nicolson, Susan C; Spray, Thomas L; Gaynor, J William; Fuller, Stephanie; Keller, Marc S; Harris, Matthew A; Yoganathan, Ajit P; Whitehead, Kevin K
2014-12-15
Pulse-wave velocity (PWV), a measure of arterial stiffness, is a known independent risk factor for cardiovascular events. Patients with single ventricle who undergo aortic to pulmonary anastomosis (recon) have noncompliant patch material inserted into the neoaorta, possibly increasing vessel stiffness and afterload. The purpose of this study is to determine if PWV in patients with single ventricle differed between those who did and those who did not undergo aortic reconstruction (nonrecon). We retrospectively reviewed cardiac magnetic resonance anatomic, cine, and phase contrast evaluations in the ascending aorta and descending aorta (DAo) at the level of the diaphragm data from 126 patients with single ventricle (8.6 ± 8.0 years) from January 2012 to May 2013. Significance = p <0.05. Seventy-five patients underwent recon and 51 did not. PWV in recon was significantly higher than in nonrecon (3.9 ± 0.9 m/s vs 3.2 ± 1.0 m/s, p = 0.008); in recon, patients >13 years old had a higher PWV than those <7 years (4.5 ± 0.6 vs 3.5 ± 0.7 m/s, p = 0.004). Whether <7 or >13 years old, PWV of those with recon was higher than nonrecon DAo distensibility was similar between both groups. There was no difference in age, body surface area, or cardiac index between recon and nonrecon. No correlations between various hemodynamic and ventricular function parameters with PWV were noted. In conclusion, PWV in recon is higher than in nonrecon with similar DAo distensibility implicating the aortic reconstruction as a possible cause of increased afterload; older recon patients have stiffer aortas than younger ones, possibly imposing an additional cardiovascular risk in the future. Other biomaterials may potentially moderate PWV if clinical outcome is adversely affected. Copyright © 2014 Elsevier Inc. All rights reserved.
Boyer, Marjorie; Lévesque, Valérie; Poirier, Paul; Marette, André; Mitchell, Patricia L; Mora, Samia; Mathieu, Patrick; Després, Jean-Pierre; Larose, Éric; Arsenault, Benoit J
2018-06-01
Our objective was to identify the determinants of high-density lipoprotein cholesterol efflux capacity (HDL-CEC) changes in patients with coronary artery disease who participated in a lifestyle modification program aimed at increasing physical activity levels and improving diet quality. A total of 86 men with coronary artery disease aged between 35 and 80 years participated in a 1-year lifestyle modification program that aimed to achieve a minimum of 150 minutes of aerobic physical activity weekly and improve diet quality. HDL-CECs were measured before and after the 1-year intervention using 3 H-cholesterol-labeled J774 and HepG2 cells. Visceral, subcutaneous, and cardiac adipose tissue levels were assessed before and after the intervention using magnetic resonance imaging. Lipoprotein particle size and concentrations were measured by proton nuclear magnetic resonance spectroscopy and a complete lipoprotein-lipid profile was obtained. At baseline, the best correlate of HDL-CECs were apolipoprotein AI ( R 2 =0.35, P <0.0001) and high-density lipoprotein cholesterol ( R 2 =0.21, P <0.0001) for J774-HDL-CECs and HepG2-HDL-CECs, respectively. Baseline and longitudinal changes in HDL-CECs were associated with several lipoprotein size and concentration indices, although high-density lipoprotein cholesterol was the best predictor of longitudinal changes in J774-HDL-CECs ( R 2 =0.18, P =0.002) and apolipoprotein AI was found to be the best predictor of longitudinal changes in HepG2 cholesterol efflux capacities ( R 2 =0.21, P =0.002). Results of this study suggest that increases in high-density lipoprotein cholesterol and apolipoprotein AI levels typically observed in patients with coronary artery disease undergoing healthy lifestyle modification therapy may be indicative of higher plasma concentrations of functional high-density lipoprotein particles. © 2018 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.
Finite Element Modeling of Magnetically-Damped Convection during Solidification
NASA Technical Reports Server (NTRS)
deGroh, H. C.; Li, B. Q.; Lu, X.
1998-01-01
A fully 3-D, transient finite element model is developed to represent the magnetic damping effects on complex fluid flow, heat transfer and electromagnetic field distributions in a Sn- 35.5%Pb melt undergoing unidirectional solidification. The model is developed based on our in- house finite element code for the fluid flow, heat transfer and electromagnetic field calculations. The numerical model is tested against numerical and experimental results for water as reported in literature. Various numerical simulations are carried out for the melt convection and temperature distribution with and without the presence of a transverse magnetic field. Numerical results show that magnetic damping can be effectively applied to stabilize melt flow, reduce turbulence and flow levels in the melt and over a certain threshold value a higher magnetic field resulted in a greater reduction in velocity. Also, for the study of melt flow instability, a long enough running time is needed to ensure the final fluid flow recirculation pattern. Moreover, numerical results suggest that there seems to exist a threshold value of applied magnetic field, above which magnetic damping becomes possible and below which the 0 convection in the melt is actually enhanced.
Light-dependent magnetoreception in birds: the crucial step occurs in the dark.
Wiltschko, Roswitha; Ahmad, Margaret; Nießner, Christine; Gehring, Dennis; Wiltschko, Wolfgang
2016-05-01
The Radical Pair Model proposes that the avian magnetic compass is based on spin-chemical processes: since the ratio between the two spin states singlet and triplet of radical pairs depends on their alignment in the magnetic field, it can provide information on magnetic directions. Cryptochromes, blue light-absorbing flavoproteins, with flavin adenine dinucleotide as chromophore, are suggested as molecules forming the radical pairs underlying magnetoreception. When activated by light, cryptochromes undergo a redox cycle, in the course of which radical pairs are generated during photo-reduction as well as during light-independent re-oxidation. This raised the question as to which radical pair is crucial for mediating magnetic directions. Here, we present the results from behavioural experiments with intermittent light and magnetic field pulses that clearly show that magnetoreception is possible in the dark interval, pointing to the radical pair formed during flavin re-oxidation. This differs from the mechanism considered for cryptochrome signalling the presence of light and rules out most current models of an avian magnetic compass based on the radical pair generated during photo-reduction. Using the radical pair formed during re-oxidation may represent a specific adaptation of the avian magnetic compass. © 2016 The Authors.
Thermodynamics of ferrofluids in applied magnetic fields.
Elfimova, Ekaterina A; Ivanov, Alexey O; Camp, Philip J
2013-10-01
The thermodynamic properties of ferrofluids in applied magnetic fields are examined using theory and computer simulation. The dipolar hard sphere model is used. The second and third virial coefficients (B(2) and B(3)) are evaluated as functions of the dipolar coupling constant λ, and the Langevin parameter α. The formula for B(3) for a system in an applied field is different from that in the zero-field case, and a derivation is presented. The formulas are compared to results from Mayer-sampling calculations, and the trends with increasing λ and α are examined. Very good agreement between theory and computation is demonstrated for the realistic values λ≤2. The analytical formulas for the virial coefficients are incorporated in to various forms of virial expansion, designed to minimize the effects of truncation. The theoretical results for the equation of state are compared against results from Monte Carlo simulations. In all cases, the so-called logarithmic free energy theory is seen to be superior. In this theory, the virial expansion of the Helmholtz free energy is re-summed in to a logarithmic function. Its success is due to the approximate representation of high-order terms in the virial expansion, while retaining the exact low-concentration behavior. The theory also yields the magnetization, and a comparison with simulation results and a competing modified mean-field theory shows excellent agreement. Finally, the putative field-dependent critical parameters for the condensation transition are obtained and compared against existing simulation results for the Stockmayer fluid. Dipolar hard spheres do not undergo the transition, but the presence of isotropic attractions, as in the Stockmayer fluid, gives rise to condensation even in zero field. A comparison of the relative changes in critical parameters with increasing field strength shows excellent agreement between theory and simulation, showing that the theoretical treatment of the dipolar interactions is robust.
Consolino, Lorena; Longo, Dario Livio; Dastrù, Walter; Cutrin, Juan Carlos; Dettori, Daniela; Lanzardo, Stefania; Oliviero, Salvatore; Cavallo, Federica; Aime, Silvio
2016-07-15
Tumour progression depends on several sequential events that include the microenvironment remodelling processes and the switch to the angiogenic phenotype, leading to new blood vessels recruitment. Non-invasive imaging techniques allow the monitoring of functional alterations in tumour vascularity and cellularity. The aim of this work was to detect functional changes in vascularisation and cellularity through Dynamic Contrast Enhanced (DCE) and Diffusion Weighted (DW) Magnetic Resonance Imaging (MRI) modalities during breast cancer initiation and progression of a transgenic mouse model (BALB-neuT mice). Histological examination showed that BALB-neuT mammary glands undergo a slow neoplastic progression from simple hyperplasia to invasive carcinoma, still preserving normal parts of mammary glands. DCE-MRI results highlighted marked functional changes in terms of vessel permeability (K(trans) , volume transfer constant) and vascularisation (vp , vascular volume fraction) in BALB-neuT hyperplastic mammary glands if compared to BALB/c ones. When breast tissue progressed from simple to atypical hyperplasia, a strong increase in DCE-MRI biomarkers was observed in BALB-neuT in comparison to BALB/c mice (K(trans) = 5.3 ± 0.7E-4 and 3.1 ± 0.5E-4; vp = 7.4 ± 0.8E-2 and 4.7 ± 0.6E-2 for BALB-neuT and BALB/c, respectively) that remained constant during the successive steps of the neoplastic transformation. Consistent with DCE-MRI observations, microvessel counting revealed a significant increase in tumour vessels. Our study showed that DCE-MRI estimates can accurately detect the angiogenic switch at early step of breast cancer carcinogenesis. These results support the view that this imaging approach is an excellent tool to characterize microvasculature changes, despite only small portions of the mammary glands developed neoplastic lesions in a transgenic mouse model. © 2016 UICC.
Hampstead, Benjamin M; Sathian, Krishnankutty; Bikson, Marom; Stringer, Anthony Y
2017-09-01
Memory deficits characterize Alzheimer's dementia and the clinical precursor stage known as mild cognitive impairment. Nonpharmacologic interventions hold promise for enhancing functioning in these patients, potentially delaying functional impairment that denotes transition to dementia. Previous findings revealed that mnemonic strategy training (MST) enhances long-term retention of trained stimuli and is accompanied by increased blood oxygen level-dependent signal in the lateral frontal and parietal cortices as well as in the hippocampus. The present study was designed to enhance MST generalization, and the range of patients who benefit, via concurrent delivery of transcranial direct current stimulation (tDCS). This protocol describes a prospective, randomized controlled, four-arm, double-blind study targeting memory deficits in those with mild cognitive impairment. Once randomized, participants complete five consecutive daily sessions in which they receive either active or sham high definition tDCS over the left lateral prefrontal cortex, a region known to be important for successful memory encoding and that has been engaged by MST. High definition tDCS (active or sham) will be combined with either MST or autobiographical memory recall (comparable to reminiscence therapy). Participants undergo memory testing using ecologically relevant measures and functional magnetic resonance imaging before and after these treatment sessions as well as at a 3-month follow-up. Primary outcome measures include face-name and object-location association tasks. Secondary outcome measures include self-report of memory abilities as well as a spatial navigation task (near transfer) and prose memory (medication instructions; far transfer). Changes in functional magnetic resonance imaging will be evaluated during both task performance and the resting-state using activation and connectivity analyses. The results will provide important information about the efficacy of cognitive and neuromodulatory techniques as well as the synergistic interaction between these promising approaches. Exploratory results will examine patient characteristics that affect treatment efficacy, thereby identifying those most appropriate for intervention.
Dynamic MRI confirms support of the mid-urethra by TVT and TVT-O surgery for stress incontinence.
Rinne, Kirsi; Kainulainen, Sakari; Aukee, Sinikka; Heinonen, Seppo; Nilsson, Carl G
2011-06-01
To study changes in mid-urethral function with dynamic MRI in stress urinary incontinent women undergoing either tension-free vaginal tape (TVT) or TVT-obturator sling operations. Prospective clinical study. University hospital. Forty-two parous women with stress urinary incontinence recruited to dynamic magnetic resonance imaging before and after mid-urethral sling surgery. Control group of 16 healthy women. Dynamic magnetic resonance imaging at rest, during pelvic floor muscle contraction, coughing and voiding with a bladder volume of 200-300 ml. X- and Y- coordinates were used to determine the location of the mid-urethra during these activities. Changes in mid-urethral position after TVT and TVT-obturator operations during the different activities. Postoperatively the women could elevate their mid-urethra by pelvic floor muscle contraction significantly higher than before the operation (p<0.05). Despite a different support angle between the TVT and the TVT-O mid-urethral slings, we could not see any differences in the movement patterns. Mid-urethral slings support the mid-urethra and restrict downward movement during different activities. Movement patterns are similar after TVT and TVT-O operations. © 2011 The Authors Acta Obstetricia et Gynecologica Scandinavica© 2011 Nordic Federation of Societies of Obstetrics and Gynecology.
Low temperature specific heat of frustrated antiferromagnet HoInCu4
NASA Astrophysics Data System (ADS)
Weickert, Franziska; Fritsch, Veronika; Bambaugh, Ryan; Sarrao, John; Thompson, Joe D.; Movshovich, Roman
2014-03-01
We present low temperature specific heat measurements of single crystal HoInCu4, down to 35 mK and in magnetic field up to 12 Tesla. Ho atoms are arranged in an FCC lattice of the edge-sharing tetrahedra, and undergo an antiferromagnetic ordering at TN = 0.76 K, with the frustration parameter f = -ΘCW /TN of 14.3. Magnetic AF order is suppressed in field H0 ~ 4 T. The low temperature Schottky anomaly due to Ho evolves smoothly as a function of field through H0 and TN. The peak value of the anomaly remains roughly constant from 0 T to 12 T. The temperature of the anomaly's peak remains constant at TSch ~ 170 mK for H
Overcoming thermal noise in non-volatile spin wave logic
NASA Astrophysics Data System (ADS)
Dutta, Sourav; Nikonov, Dmitri; Manipatruni, Sasikanth; Young, Ian; Naeemi, Azad
Spin waves are propagating disturbances in magnetically ordered materials. To compete as a promising candidate for beyond-CMOS application, the all-magnon based computing system must undergo the essential steps of careful selection of materials and demonstrate robustness with respect to thermal noise/variability. Here, we identify suitable materials and investigate two viable options for translating the theoretical idea of phase-dependent switching of the spin wave detector to a practical realization of a thermally reliable magnonic device by - (a) using the built-in strain in the ME cell, arising from the lattice mismatch and/or thermal expansion coefficient mismatch between the film and the substrate, for compensation of the demagnetization, and (b) using an exchange-spring structure that exhibits a strong exchange-coupling between the ME cell and PMA SWB and provides a modification of the energy landscape of the ME cell magnet. A high switching success and error-free logic functionality can be ensured if the amplitude of the detected spin wave (< θ >) remains higher than a threshold value of around 6°C and the detected phase falls within the window from 280°C through 0 to 20°C or from 100°C to 200°C with a maximum allowable ϕ range of around 100°C.
On the structure and statistical theory of turbulence of extended magnetohydrodynamics
Miloshevich, George; Lingam, Manasvi; Morrison, Philip J.
2017-01-16
Recent progress regarding the noncanonical Hamiltonian formulation of extended magnetohydrodynamics (XMHD), a model with Hall drift and electron inertia, is summarized. The advantages of the Hamiltonian approach are invoked to study some general properties of XMHD turbulence, and to compare them against their ideal MHD counterparts. For instance, the helicity flux transfer rates for XMHD are computed, and Liouville's theorem for this model is also verified. The latter is used, in conjunction with the absolute equilibrium states, to arrive at the spectra for the invariants, and to determine the direction of the cascades, e.g., generalizations of the well-known ideal MHDmore » inverse cascade of magnetic helicity. After a similar analysis is conducted for XMHD by inspecting second order structure functions and absolute equilibrium states, a couple of interesting results emerge. When cross helicity is taken to be ignorable, the inverse cascade of injected magnetic helicity also occurs in the Hall MHD range-this is shown to be consistent with previous results in the literature. In contrast, in the inertial MHD range, viz at scales smaller than the electron skin depth, all spectral quantities are expected to undergo direct cascading. Finally, the consequences and relevance of our results in space and astrophysical plasmas are also briefly discussed.« less
A new polyester based on allyl α-hydroxy glutarate as shell for magnetite nanoparticles
NASA Astrophysics Data System (ADS)
Nan, Alexandrina; Feher, Ioana Coralia
2017-12-01
Allyl side-chain-functionalized lactide was synthesized from commercially available glutamic acid and polymerized by ring opening polymerization using 4-dimethylaminopyridine as an organocatalyst in the presence of magnetic nanoparticles. The resulting magnetic nanostructures coated with the allyl-containing polyester were then functionalized with cysteine by thiol-ene click reaction leading to highly functionalized magnetic nano-platforms of practical interest. The polyester precursors were characterized by nuclear magnetic resonance and mass spectrometry. The morphology of magnetic nanostructures based on the functionalized polyester was determined by transmission electron microscopy TEM, while the chemical structure was investigated by FT-IR. TGA investigations and the magnetic properties of the magnetic nanostructures are also described.
Edlow, Brian L; Keene, C Dirk; Perl, Daniel P; Iacono, Diego; Folkerth, Rebecca D; Stewart, William; Mac Donald, Christine L; Augustinack, Jean; Diaz-Arrastia, Ramon; Estrada, Camilo; Flannery, Elissa; Gordon, Wayne A; Grabowski, Thomas J; Hansen, Kelly; Hoffman, Jeanne; Kroenke, Christopher; Larson, Eric B; Lee, Patricia; Mareyam, Azma; McNab, Jennifer A; McPhee, Jeanne; Moreau, Allison L; Renz, Anne; Richmire, KatieRose; Stevens, Allison; Tang, Cheuk Y; Tirrell, Lee S; Trittschuh, Emily H; van der Kouwe, Andre; Varjabedian, Ani; Wald, Lawrence L; Wu, Ona; Yendiki, Anastasia; Young, Liza; Zöllei, Lilla; Fischl, Bruce; Crane, Paul K; Dams-O'Connor, Kristen
2018-05-03
Epidemiological studies suggest that a single moderate-to-severe traumatic brain injury (TBI) is associated with an increased risk of neurodegenerative disease, including Alzheimer's disease (AD) and Parkinson's disease (PD). Histopathological studies describe complex neurodegenerative pathologies in individuals exposed to single moderate-to-severe TBI or repetitive mild TBI, including chronic traumatic encephalopathy (CTE). However, the clinicopathological links between TBI and post-traumatic neurodegenerative diseases such as AD, PD, and CTE remain poorly understood. Here, we describe the methodology of the Late Effects of TBI (LETBI) study, whose goals are to characterize chronic post-traumatic neuropathology and to identify in vivo biomarkers of post-traumatic neurodegeneration. LETBI participants undergo extensive clinical evaluation using National Institutes of Health TBI Common Data Elements, proteomic and genomic analysis, structural and functional magnetic resonance imaging (MRI), and prospective consent for brain donation. Selected brain specimens undergo ultra-high resolution ex vivo MRI and histopathological evaluation including whole-mount analysis. Co-registration of ex vivo and in vivo MRI data enables identification of ex vivo lesions that were present during life. In vivo signatures of postmortem pathology are then correlated with cognitive and behavioral data to characterize the clinical phenotype(s) associated with pathological brain lesions. We illustrate the study methods and demonstrate proof of concept for this approach by reporting results from the first LETBI participant, who despite the presence of multiple in vivo and ex vivo pathoanatomic lesions had normal cognition and was functionally independent until her mid-80s. The LETBI project represents a multidisciplinary effort to characterize post-traumatic neuropathology and identify in vivo signatures of postmortem pathology in a prospective study.
Thermally generated magnetic fields in laser-driven compressions and explosions
NASA Technical Reports Server (NTRS)
Tidman, D. A.
1975-01-01
The evolution of thermally generated magnetic fields in a plasma undergoing a nearly spherically symmetric adiabatic compression or expansion is calculated. The analysis is applied to obtain approximate results for the development of magnetic fields in laser-driven compression and explosion of a pellet of nuclear fuel. Localized sources, such as those occurring at composition boundaries in structured pellets or at shock fronts, give stronger fields than those deriving from smoothly distributed asymmetries. Although these fields may approach 10 million G in the late stages of compression, this is not expected to present difficulties for the compression process. Assuming ignition of a nuclear explosion occurs, the sources become much stronger, and values of approximately 10 billion G are obtained at tamper boundaries assuming a 20% departure from spherical symmetry during the explosion.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gloss, Jonas; Institute of Physical Engineering, Faculty of Mechanical Engineering, Brno University of Technology, Technická 2, 616 69 Brno; Shah Zaman, Sameena
2013-12-23
Metastable face-centered cubic (fcc) Fe/Cu(100) thin films are good candidates for ion-beam magnetic patterning due to their magnetic transformation upon ion-beam irradiation. However, pure fcc Fe films undergo spontaneous transformation when their thickness exceeds 10 ML. This limit can be extended to approximately 22 ML by deposition of Fe at increased CO background pressures. We show that much thicker films can be grown by alloying with Ni for stabilizing the fcc γ phase. The amount of Ni necessary to stabilize nonmagnetic, transformable fcc Fe films in dependence on the residual background pressure during the deposition is determined and a phasemore » diagram revealing the transformable region is presented.« less
Ajayi, Ayobami; Hwang, Wei-Ting; Vapiwala, Neha; Rosen, Mark; Chapman, Christina H; Both, Stefan; Shah, Meera; Wang, Xingmei; Agawu, Atu; Gabriel, Peter; Christodouleas, John; Tochner, Zelig; Deville, Curtiland
2016-01-01
There is growing evidence supporting incorporating multiparametric (mp) magnetic resonance imaging (MRI) scans into risk stratification, active surveillance, and treatment paradigms for prostate cancer. The purpose of our study was to determine whether demographic disparities exist in staging MRI utilization for prostate cancer patients. An institutional database of 705 nonmetastatic prostate cancer patients treated with radiation therapy from 2005 through 2013 was used to identify patients undergoing versus not undergoing pretreatment diagnostic prostate mpMRI. Uni- and multivariable logistic regression evaluated the relationship of clinical and demographic characteristics with MRI utilization. All demographic variables assessed, except the other race category, were significantly associated with MRI utilization (all P < .05), including age (odds ratio [OR], 0.92), black race (OR, 0.51), poverty (OR, 0.53), closer distance to radiation facility (OR, 1.79), and nonprivate primary insurance (OR, 0.57) on univariable analysis, while clinical stage T3 (OR, 3.37) was the only clinical characteristic. On multivariable analysis stratified by D'Amico risk group, age remained significant across all risk groups, whereas the black versus white racial (OR, 0.21; 95% confidence interval, 0.08-0.55) and nonprivate versus private insurance type (OR, 0.37; 95% confidence interval, 0.16-0.86) disparities persisted in the low-risk group. Clinical stage T3 remained associated in the high-risk group. For race specifically, the percentages of whites, blacks, and others undergoing MRI in the overall cohort and by risk group were, respectively: overall, 80% (343/427), 68% (156/231), and 85% (40/47); low risk, 86%, 56%, and 63%; intermediate risk, 79%, 72%, and 95%; and high risk, 72%, 72%, and 100%. In this urban, academic center cohort, older patients across all risk groups and black or nonprivate insurance patients in the low risk group were less likely to undergo staging prostate MRI scans. Further research should investigate these differences to ensure equitable utilization across all demographic groups considering the burden of prostate cancer disparities.
Kosmidou, Ioanna; Redfors, Björn; Selker, Harry P; Thiele, Holger; Patel, Manesh R; Udelson, James E; Magnus Ohman, E; Eitel, Ingo; Granger, Christopher B; Maehara, Akiko; Kirtane, Ajay; Généreux, Philippe; Jenkins, Paul L; Ben-Yehuda, Ori; Mintz, Gary S; Stone, Gregg W
2017-06-01
Studies have reported less favourable outcomes in women compared with men after primary percutaneous coronary intervention (PCI) in ST-segment elevation myocardial infarction (STEMI). Whether sex-specific differences in the magnitude or prognostic impact of infarct size or post-infarction cardiac function explain this finding is unknown. We pooled patient-level data from 10 randomized primary PCI trials in which infarct size was measured within 1 month (median 4 days) by either cardiac magnetic resonance imaging or technetium-99m sestamibi single-photon emission computed tomography. We assessed the association between sex, infarct size, and left ventricular ejection fraction (LVEF) and the composite rate of death or heart failure (HF) hospitalization within 1 year. Of 2632 patients with STEMI undergoing primary PCI, 587 (22.3%) were women. Women were older than men and had a longer delay between symptom onset and reperfusion. Infarct size did not significantly differ between women and men, and women had higher LVEF. Nonetheless, women had a higher 1-year rate of death or HF hospitalization compared to men, and while infarct size was a strong independent predictor of 1-year death or HF hospitalization (P < 0.0001), no interaction was present between sex and infarct size or LVEF on the risk of death or HF hospitalization. In this large-scale, individual patient-level pooled analysis of patients with STEMI undergoing primary PCI, women had a higher 1-year rate of death or HF hospitalization compared to men, a finding not explained by sex-specific differences in the magnitude or prognostic impact of infarct size or by differences in post-infarction cardiac function. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.
Spasojević-Dimitrijeva, Brankica; Kotur-Stevuljević, Jelena; Đukić, Milan; Paripović, Dušan; Miloševski-Lomić, Gordana; Spasojević-Kalimanovska, Vesna; Pavićević, Polina; Mitrović, Jadranka; Kostić, Mirjana
2017-01-01
Background New renal biomarkers such as neutrophil gelatinase-associated lipocalin (NGAL) and kidney injury molecule-1 (KIM-1) show promise in early diagnosis of contrast media induced acute kidney injury (CI-AKI). The purpose of our study was to compare the subclinical nephrotoxicity (a condition without changes in standard renal biomarkers) of gadolinium-based contrast media (Gd-DTPA, gadopentetate dimeglumine) and iodinated-based contrast media (iopromide) in pediatric patients with normal kidney function. Material/Methods The first group (n=58) of patients included in the study were undergoing angiography with iopromide, and the second group (n=65) were undergoing magnetic resonance (MR) angiography/urography with Gd-DTPA administration. The concentrations of NGAL and KIM-1 were measured four times in the urine (pre-contrast, then at four hours, 24 hours, and 48 hours after contrast administration), and serum NGAL was measured at 0 (baseline), 24 hours, and 48 hours after contrast exposure. Results After 24 hours, serum NGAL increase of ≥25% was noticed in 32.6% of the patients in the iopromide group and in 25.45% of the patients in the gadolinium group, with significantly higher average percent of this increase in first group (62.23% vs. 36.44%, p=0.002). In the Gd-DTPA group, we observed a statistically significant increase in urinary KIM-1 24 hours after the procedure. Normalized urinary KIM-1, 24 hours after contrast exposure, was a better predictive factor for CI-AKI than other biomarkers (AUC 0.757, cut off 214 pg/mg, sensitivity 83.3%, specificity 54.2%, p=0.035). Conclusions In children with normal renal function, exposure to iodinated-based and gadolinium-based media might lead to subclinical nephrotoxicity, which could be detected using serum NGAL and urinary KIM-1. PMID:28874655
Dual immobilization and magnetic manipulation of magnetic nanoparticles
NASA Astrophysics Data System (ADS)
Yang, S. Y.; Jian, Z. F.; Horng, H. E.; Hong, Chin-Yih; Yang, H. C.; Wu, C. C.; Lee, Y. H.
By suitably bio-functionalizing the surfaces, magnetic nanoparticles are able to bind specific biomolecules, and may serve as vectors for delivering bio-entities to target tissues. In this work, the synthesis of bio-functionalized magnetic nanoparticles with two kinds of bio-probes is developed. Here, the stem cell is selected as a to-be-delivered bio-entity and infarcted myocardium is the target issue. Thus, cluster designation-34 (CD-34) on stem cell and creatine kinase-MB (CK-MB) (or troponin I) on infarcted myocardium are the specific biomolecules to be bound with bio-functionalized magnetic nanoparticles. In addition to demonstrating the co-coating of two kinds of bio-probes on a magnetic nanoparticle, the feasibility of manipulation on bio-functionalized magnetic nanoparticles by external magnetic fields is investigated.
Functional Magnetic Resonance Imaging for Preoperative Planning in Brain Tumour Surgery.
Lau, Jonathan C; Kosteniuk, Suzanne E; Bihari, Frank; Megyesi, Joseph F
2017-01-01
Functional magnetic resonance imaging (fMRI) is being increasingly used for the preoperative evaluation of patients with brain tumours. The study is a retrospective chart review investigating the use of clinical fMRI from 2002 through 2013 in the preoperative evaluation of brain tumour patients. Baseline demographic and clinical data were collected. The specific fMRI protocols used for each patient were recorded. Sixty patients were identified over the 12-year period. The tumour types most commonly investigated were high-grade glioma (World Health Organization grade III or IV), low-grade glioma (World Health Organization grade II), and meningioma. Most common presenting symptoms were seizures (69.6%), language deficits (23.2%), and headache (19.6%). There was a predominance of left hemispheric lesions investigated with fMRI (76.8% vs 23.2% for right). The most commonly involved lobes were frontal (64.3%), temporal (33.9%), parietal (21.4%), and insular (7.1%). The most common fMRI paradigms were language (83.9%), motor (75.0%), sensory (16.1%), and memory (10.7%). The majority of patients ultimately underwent a craniotomy (75.0%), whereas smaller groups underwent stereotactic biopsy (8.9%) and nonsurgical management (16.1%). Time from request for fMRI to actual fMRI acquisition was 3.1±2.3 weeks. Time from fMRI acquisition to intervention was 4.9±5.5 weeks. We have characterized patient demographics in a retrospective single-surgeon cohort undergoing preoperative clinical fMRI at a Canadian centre. Our experience suggests an acceptable wait time from scan request to scan completion/analysis and from scan to intervention.
Murnane, Kevin Sean; Howell, Leonard Lee
2010-08-15
Functional magnetic resonance imaging (fMRI) is a technique with significant potential to advance our understanding of multiple brain systems. However, when human subjects undergo fMRI studies they are typically conscious whereas pre-clinical fMRI studies typically utilize anesthesia, which complicates comparisons across studies. Therefore, we have developed an apparatus suitable for imaging conscious rhesus monkeys. In order to minimize subject stress and spatial motion, each subject was acclimated to the necessary procedures over several months. The effectiveness of this process was then evaluated, in fully trained subjects, by quantifying objective physiological measures. These physiological metrics were stable both within and across sessions and did not differ from when these same subjects were immobilized using standard primate handling procedures. Subject motion and blood oxygenation level dependent (BOLD) fMRI measurements were then evaluated by scanning subjects under three different conditions: the absence of stimulation, presentation of a visual stimulus, or administration of intravenous (i.v.) cocaine (0.3mg/kg). Spatial motion differed neither by condition nor along the three principal axes. In addition, maximum translational and rotational motion never exceeded one half of the voxel size (0.75 mm) or 1.5 degrees, respectively. Furthermore, the localization of changes in blood oxygenation closely matched those reported in previous studies using similar stimuli. These findings document the feasibility of fMRI data collection in conscious rhesus monkeys using these procedures and allow for the further study of the neural effects of psychoactive drugs. (c) 2010 Elsevier B.V. All rights reserved.
Buchanan, Charlotte; Mohammed, Azharuddin; Cox, Eleanor; Köhler, Katrin; Canaud, Bernard; Taal, Maarten W.; Selby, Nicholas M.; Francis, Susan
2017-01-01
Hemodynamic stress during hemodialysis (HD) results in recurrent segmental ischemic injury (myocardial stunning) that drives cumulative cardiac damage. We performed a fully comprehensive study of the cardiovascular effect of dialysis sessions using intradialytic cardiac magnetic resonance imaging (MRI) to examine the comparative acute effects of standard HD versus hemodiafiltration (HDF) in stable patients. We randomly allocated 12 patients on HD (ages 32–72 years old) to either HD or HDF. Patients were stabilized on a modality for 2 weeks before undergoing serial cardiac MRI assessment during dialysis. Patients then crossed over to the other modality and were rescanned after 2 weeks. Cardiac MRI measurements included cardiac index, stroke volume index, global and regional contractile function (myocardial strain), coronary artery flow, and myocardial perfusion. Patients had mean±SEM ultrafiltration rates of 3.8±2.9 ml/kg per hour during HD and 4.4±2.5 ml/kg per hour during HDF (P=0.29), and both modalities provided a similar degree of cooling. All measures of systolic contractile function fell during HD and HDF, with partial recovery after dialysis. All patients experienced some degree of segmental left ventricular dysfunction, with severity proportional to ultrafiltration rate and BP reduction. Myocardial perfusion decreased significantly during HD and HDF. Treatment modality did not influence any of the cardiovascular responses to dialysis. In conclusion, in this randomized, crossover study, there was no significant difference in the cardiovascular response to HDF or HD with cooled dialysate as assessed with intradialytic MRI. PMID:28122851
NASA Astrophysics Data System (ADS)
Rück, Marlon; Reuther, Johannes
2018-04-01
We implement an extension of the pseudofermion functional renormalization group method for quantum spin systems that takes into account two-loop diagrammatic contributions. An efficient numerical treatment of the additional terms is achieved within a nested graph construction which recombines different one-loop interaction channels. In order to be fully self-consistent with respect to self-energy corrections, we also include certain three-loop terms of Katanin type. We first apply this formalism to the antiferromagnetic J1-J2 Heisenberg model on the square lattice and benchmark our results against the previous one-loop plus Katanin approach. Even though the renormalization group (RG) equations undergo significant modifications when including the two-loop terms, the magnetic phase diagram, comprising Néel ordered and collinear ordered phases separated by a magnetically disordered regime, remains remarkably unchanged. Only the boundary position between the disordered and the collinear phases is found to be moderately affected by two-loop terms. On the other hand, critical RG scales, which we associate with critical temperatures Tc, are reduced by a factor of ˜2 indicating that the two-loop diagrams play a significant role in enforcing the Mermin-Wagner theorem. Improved estimates for critical temperatures are also obtained for the Heisenberg ferromagnet on the three-dimensional simple cubic lattice where errors in Tc are reduced by ˜34 % . These findings have important implications for the quantum phase diagrams calculated within the previous one-loop plus Katanin approach which turn out to be already well converged.
In vitro assessment of MRI issues at 3-Tesla for a breast tissue expander with a remote port.
Linnemeyer, Hannah; Shellock, Frank G; Ahn, Christina Y
2014-04-01
A patient with a breast tissue expander may require a diagnostic assessment using magnetic resonance imaging (MRI). To ensure patient safety, this type of implant must undergo in vitro MRI testing using proper techniques. Therefore, this investigation evaluated MRI issues (i.e., magnetic field interactions, heating, and artifacts) at 3-Tesla for a breast tissue expander with a remote port. A breast tissue expander with a remote port (Integra Breast Tissue Expander, Model 3612-06 with Standard Remote Port, PMT Corporation, Chanhassen, MN) underwent evaluation for magnetic field interactions (translational attraction and torque), MRI-related heating, and artifacts using standardized techniques. Heating was evaluated by placing the implant in a gelled-saline-filled phantom and MRI was performed using a transmit/receive RF body coil at an MR system reported, whole body averaged specific absorption rate of 2.9-W/kg. Artifacts were characterized using T1-weighted and GRE pulse sequences. Magnetic field interactions were not substantial and, thus, will not pose a hazard to a patient in a 3-Tesla or less MRI environment. The highest temperature rise was 1.7°C, which is physiologically inconsequential. Artifacts were large in relation to the remote port and metal connector of the implant but will only present problems if the MR imaging area of interest is where these components are located. A patient with this breast tissue expander with a remote port may safely undergo MRI at 3-Tesla or less under the conditions used for this investigation. These findings are the first reported at 3-Tesla for a tissue expander. Copyright © 2014 Elsevier Inc. All rights reserved.
Adragão, Pedro Pulido; Cavaco, Diogo; Ferreira, António Miguel; Costa, Francisco Moscoso; Parreira, Leonor; Carmo, Pedro; Morgado, Francisco Bello; Santos, Katya Reis; Santos, Pedro Galvão; Carvalho, Maria Salomé; Durazzo, Anai; Marques, Hugo; Gonçalves, Pedro Araújo; Raposo, Luís; Mendes, Miguel
2016-03-01
Whether or not the potential advantages of using a magnetic navigation system (MNS) translate into improved outcomes in patients undergoing atrial fibrillation (AF) ablation is a question that remains unanswered. In this observational registry study, we used propensity-score matching to compare the outcomes of patients with symptomatic drug-refractory AF who underwent catheter ablation using MNS with the outcomes of those who underwent catheter ablation using conventional manual navigation. Among 1,035 eligible patients, 287 patients in each group had similar propensity scores and were included in the analysis. The primary efficacy outcome was the rate of AF relapse after a 3-month blanking period. At a mean follow-up of 2.6 ± 1.5 years, AF ablation with MNS was associated with a similar risk of AF relapse as compared with manual navigation (18.4% per year and 22.3% per year, respectively; hazard ratio 0.81, 95% CI 0.63-1.05; P = 0.108). Major complications occurred in two patients (0.7%) using MNS, and in six patients (2.1%) undergoing manually navigated ablation (P = 0.286). Fluoroscopy times were 21 ± 10 minutes in the manual navigation group, and 12 ± 9 minutes in the MNS group (P < 0.001), whereas total procedure times were 152 ± 52 minutes and 213 ± 58 minutes, respectively (P < 0.001). In this propensity-score matched comparison, magnetic navigation and conventional manual AF ablations seem to have similar relapse rates and a similar risk of complications. AF ablations with magnetic navigation take longer to perform but expose patients to significantly shorter fluoroscopy times. © 2015 Wiley Periodicals, Inc.
Glaveckaite, Sigita; Uzdavinyte-Gateliene, Egle; Petrulioniene, Zaneta; Palionis, Darius; Valeviciene, Nomeda; Kalinauskas, Gintaras; Serpytis, Pranas; Laucevicius, Aleksandras
2018-03-09
We aimed to evaluate (i) the effectiveness of combined surgery (coronary artery bypass grafting with restrictive mitral valve annuloplasty) and (ii) the late gadolinium enhancement cardiovascular magnetic resonance-based predictors of ischaemic mitral regurgitation (IMR) recurrence. The prospective analysis included 40 patients with multivessel coronary artery disease, IMR >II° and left ventricular (LV) dysfunction undergoing combined surgery. The degree of IMR and LV parameters were assessed preoperatively by transthoracic echocardiography, 3D transoesophageal echocardiography and cardiovascular magnetic resonance and postoperatively by transthoracic echocardiography. The effective mitral valve repair group (n = 30) was defined as having recurrent ischaemic mitral regurgitation (RIMR) ≤II° at the end of follow-up (25 ± 11 months). The surgery was effective: freedom from RIMR >II° at 1 and 2 years after surgery was 80% and 75%, respectively. Using multivariable logistic regression, 2 independent predictors of RIMR >II° were identified: ≥3 non-viable LV segments (odds ratio 22, P = 0.027) and ≥1 non-viable segment in the LV posterior wall (odds ratio 11, P = 0.026). Using classification trees, the best combinations of cardiovascular magnetic resonance-based and 3D transoesophageal echocardiography-based predictors for RIMR >II° were (i) posterior mitral valve leaflet angle >40° and LV end-systolic volume index >45 ml/m2 (sensitivity 100%, specificity 89%) and (ii) scar transmurality >68% in the inferior LV wall and EuroSCORE II >8 (sensitivity 83%, specificity 78%). There is a clear relationship between the amount of non-viable LV segments, especially in the LV posterior and inferior walls, and the recurrence of IMR after the combined surgery.
Lean, Cynthia L; Bourne, Roger; Thompson, John F; Scolyer, Richard A; Stretch, Jonathan; Li, Ling-Xi Lawrence; Russell, Peter; Mountford, Carolyn
2003-06-01
Accurate staging of patients with primary cutaneous melanoma includes assessment of regional lymph nodes for the presence of micrometastatic disease. Sentinel lymph node biopsy is highly accurate but is an invasive surgical procedure with a 5-10% complication rate, and requires labour-intensive and expensive histological examination to identify disease. A rapid, accurate and cost-effective non-surgical technique able to detect micrometastatic deposits of melanoma in regional lymph nodes would be of great benefit. Fine needle aspiration biopsies and tissue specimens were obtained from lymph nodes from 18 patients undergoing node resection for metastatic melanoma and five patients undergoing radical retropubic prostatectomy. One-dimensional proton magnetic resonance spectroscopy was undertaken at 360 MHz (8.5 T). Lymph nodes were cut into 3 mm thick slices and embedded. Four sequential 5 microm tissue sections were cut from each block and stained, with haematoxylin and eosin, for S100 protein, for HMB45, and again with haematoxylin and eosin, respectively. Proton magnetic resonance spectroscopy distinguished between benign and malignant lymph node tissue (P < 0.001, separate t-test) and benign and malignant lymph node fine needle aspiration biopsy (P < 0.012) based on the ratio of the integrals of resonances from lipid/other metabolites (1.8-2.5 p.p.m. region) and 'choline' (3.1-3.3 p.p.m. region). In conclusion, one-dimensional proton magnetic resonance spectroscopy on a simple fine needle aspiration biopsy can distinguish lymph nodes containing metastatic melanoma from uninvolved nodes, providing a rapid, accurate and cost-effective non-surgical technique to assess regional lymph nodes in patients with melanoma.
McCoy, Thomas M; Brown, Paul; Eastoe, Julian; Tabor, Rico F
2015-01-28
The unique charging properties of graphene oxide (GO) are exploited in the preparation of a range of noncovalent magnetic GO materials, using microparticles, nanoparticles, and magnetic surfactants. Adsorption and desorption are controlled by modification of pH within a narrow window of <2 pH units. The benefit conferred by using charge-based adsorption is that the process is reversible, and the GO can be captured and separated from the magnetic nanomaterial, such that both components can be recycled. Iron oxide (Fe2O3) microparticles form a loosely flocculated gel network with GO, which is demonstrated to undergo magnetic compressional dewatering in the presence of an external magnetic field. For composites formed from GO and Fe2O3 nanoparticles, it is found that low Fe2O3:GO mass ratios (<5:1) favor flocculation of GO, whereas higher ratios (>5:1) cause overcharging of the surfaces resulting in restabilization. The effectiveness of the GO adsorption and magnetic capture process is demonstrated by separating traditionally difficult-to-recover gold nanoparticles (d ≈ 10 nm) from water. The fully recyclable nature of the assembly and capture process, combined with the vast adsorption capacity of GO, presents obvious and appealing advantages for applications in decontamination and water treatment.
NASA Technical Reports Server (NTRS)
Moore, Ronald L.
1998-01-01
The prominence that erupts in a prominence eruption is a magnetic structure in the chromosphere and corona. It is visible in chromospheric images by virtue of chromospheric-temperature plasma suspended in the magnetic field, and belongs to that large class of magnetic structures appropriately called filaments because of their characteristic sinewy sigmoidal form. Hence, the term "filament eruption" is used interchangeably with the term "prominence eruption". The magnetic field holding a filament is prone to undergo explosive changes in configuration. In these upheavals, because the filament material is compelled by its high conductivity to ride with the magnetic field that threads it, this material is a visible tracer of the field motion. The part of the magnetic explosion displayed by the entrained filament material is the phenomenon known as a filament eruption, the topic of this article. This article begins with a description of basic observed characteristics of filament eruptions, with attention to the magnetic fields, flares, and coronal mass ejections in which erupting filaments are embedded. The present understanding of these characteristics in terms of the form and action of the magnetic field is then laid out by means of a rudimentary three-dimensional model of the field. The article ends with basic questions that this picture leaves unresolved and with remarks on the observations needed to probe these questions.
Temperature and magnetic-field driven dynamics in artificial magnetic square ice
Drouhin, Henri-Jean; Wegrowe, Jean-Eric; Razeghi, Manijeh; ...
2015-09-08
Artificial spin ices are often spoken of as being realisations of some of the celebrated vertex models of statistical mechanics, where the exact microstate of the system can be imaged using advanced magnetic microscopy methods. The fact that a stable image can be formed means that the system is in fact athermal and not undergoing the usual finite-temperature fluctuations of a statistical mechanical system. In this paper we report on the preparation of artificial spin ices with islands that are thermally fluctuating due to their very small size. The relaxation rate of these islands was determined using variable frequency focusedmore » magneto-optic Kerr measurements. We performed magnetic imaging of artificial spin ice under varied temperature and magnetic field using X-ray transmission microscopy which uses X-ray magnetic circular dichroism to generate magnetic contrast. Furthermore, we have developed an on-membrane heater in order to apply temperatures in excess of 700 K and have shown increased dynamics due to higher temperature. Due to the ‘photon-in, photon-out' method employed here, it is the first report where it is possible to image the microstates of an ASI system under the simultaneous application of temperature and magnetic field, enabling the determination of relaxation rates, coercivties, and the analysis of vertex population during reversal.« less
Temperature and magnetic-field driven dynamics in artificial magnetic square ice
DOE Office of Scientific and Technical Information (OSTI.GOV)
Drouhin, Henri-Jean; Wegrowe, Jean-Eric; Razeghi, Manijeh
Artificial spin ices are often spoken of as being realisations of some of the celebrated vertex models of statistical mechanics, where the exact microstate of the system can be imaged using advanced magnetic microscopy methods. The fact that a stable image can be formed means that the system is in fact athermal and not undergoing the usual finite-temperature fluctuations of a statistical mechanical system. In this paper we report on the preparation of artificial spin ices with islands that are thermally fluctuating due to their very small size. The relaxation rate of these islands was determined using variable frequency focusedmore » magneto-optic Kerr measurements. We performed magnetic imaging of artificial spin ice under varied temperature and magnetic field using X-ray transmission microscopy which uses X-ray magnetic circular dichroism to generate magnetic contrast. Furthermore, we have developed an on-membrane heater in order to apply temperatures in excess of 700 K and have shown increased dynamics due to higher temperature. Due to the ‘photon-in, photon-out' method employed here, it is the first report where it is possible to image the microstates of an ASI system under the simultaneous application of temperature and magnetic field, enabling the determination of relaxation rates, coercivties, and the analysis of vertex population during reversal.« less
Modeling of Stability of Electrostatic and Magnetostatic Systems
2017-06-01
unlimited. 13. SUPPLEMENTARY NOTES 14. ABSTRACT Electromagnetic systems undergo a variety of different instabilities. A broad class of those...15. SUBJECT TERMS electromagnetism , morphological instabilities, computational algorithm, gradient minimization, morphology patterns, motion by mean...Nordmark AB. Magnetic field and current are zero inside ideal conductors. Prog Electromagn Res B. 2011(27):187–212. 4. Stratton JA. Electromagnetic theory
Chemically engineered graphene-based 2D organic molecular magnet.
Hong, Jeongmin; Bekyarova, Elena; de Heer, Walt A; Haddon, Robert C; Khizroev, Sakhrat
2013-11-26
Carbon-based magnetic materials and structures of mesoscopic dimensions may offer unique opportunities for future nanomagnetoelectronic/spintronic devices. To achieve their potential, carbon nanosystems must have controllable magnetic properties. We demonstrate that nitrophenyl functionalized graphene can act as a room-temperature 2D magnet. We report a comprehensive study of low-temperature magnetotransport, vibrating sample magnetometry (VSM), and superconducting quantum interference (SQUID) measurements before and after radical functionalization. Following nitrophenyl (NP) functionalization, epitaxially grown graphene systems can become organic molecular magnets with ferromagnetic and antiferromagnetic ordering that persists at temperatures above 400 K. The field-dependent, surface magnetoelectric properties were studied using scanning probe microscopy (SPM) techniques. The results indicate that the NP-functionalization orientation and degree of coverage directly affect the magnetic properties of the graphene surface. In addition, graphene-based organic magnetic nanostructures were found to demonstrate a pronounced magneto-optical Kerr effect (MOKE). The results were consistent across different characterization techniques and indicate room-temperature magnetic ordering along preferred graphene orientations in the NP-functionalized samples. Chemically isolated graphene nanoribbons (CINs) were observed along the preferred functionality directions. These results pave the way for future magnetoelectronic/spintronic applications based on promising concepts such as current-induced magnetization switching, magnetoelectricity, half-metallicity, and quantum tunneling of magnetization.
Ahlander, Britt-Marie; Årestedt, Kristofer; Engvall, Jan; Maret, Eva; Ericsson, Elisabeth
2016-06-01
To develop and validate a new instrument measuring patient anxiety during Magnetic Resonance Imaging examinations, Magnetic Resonance Imaging- Anxiety Questionnaire. Questionnaires measuring patients' anxiety during Magnetic Resonance Imaging examinations have been the same as used in a wide range of conditions. To learn about patients' experience during examination and to evaluate interventions, a specific questionnaire measuring patient anxiety during Magnetic Resonance Imaging is needed. Psychometric cross-sectional study with test-retest design. A new questionnaire, Magnetic Resonance Imaging-Anxiety Questionnaire, was designed from patient expressions of anxiety in Magnetic Resonance Imaging-scanners. The sample was recruited between October 2012-October 2014. Factor structure was evaluated with exploratory factor analysis and internal consistency with Cronbach's alpha. Criterion-related validity, known-group validity and test-retest was calculated. Patients referred for Magnetic Resonance Imaging of either the spine or the heart, were invited to participate. The development and validation of Magnetic Resonance Imaging-Anxiety Questionnaire resulted in 15 items consisting of two factors. Cronbach's alpha was found to be high. Magnetic Resonance Imaging-Anxiety Questionnaire correlated higher with instruments measuring anxiety than with depression scales. Known-group validity demonstrated a higher level of anxiety for patients undergoing Magnetic Resonance Imaging scan of the heart than for those examining the spine. Test-retest reliability demonstrated acceptable level for the scale. Magnetic Resonance Imaging-Anxiety Questionnaire bridges a gap among existing questionnaires, making it a simple and useful tool for measuring patient anxiety during Magnetic Resonance Imaging examinations. © 2016 The Authors. Journal of Advanced Nursing Published by John Wiley & Sons Ltd.
Study of wave form compensation at CSNS/RCS magnets
NASA Astrophysics Data System (ADS)
Xu, S. Y.; Fu, S. N.; Wang, S.; Kang, W.; Qi, X.; Li, L.; Deng, C. D.; Zhou, J. X.
2018-07-01
A method of wave form compensation for magnets of the Rapid Cycling Synchrotron (RCS), which is based on transfer function between magnetic field and exciting current, was investigated on the magnets of RCS of Chinese Spallation Neutron Source (CSNS). By performing wave form compensation, the magnetic field ramping function for RCS magnets can be accurately controlled to the given wave form, which is not limited to sine function. The method of wave form compensation introduced in this paper can be used to reduce the magnetic field tracking errors, and can also be used to accurately control the betatron tune for RCS.
Mason, Ross; Kapoor, Anil; Liu, Zhihui; Saarela, Olli; Tanguay, Simon; Jewett, Michael; Finelli, Antonio; Lacombe, Louis; Kawakami, Jun; Moore, Ronald; Morash, Christopher; Black, Peter; Rendon, Ricardo A
2016-11-01
Patients who undergo surgical management of renal cell carcinoma (RCC) are at risk for chronic kidney disease and its sequelae. This study describes the natural history of renal function after radical and partial nephrectomy and explores factors associated with postoperative decline in renal function. This is a multi-institutional cohort study of patients in the Canadian Kidney Cancer Information System who underwent partial or radical nephrectomy for RCC. Estimated glomerular filtration rate (eGFR) and stage of chronic kidney disease were determined preoperatively and at 3, 12, and 24 months postoperatively. Linear regression was used to determine the association between postoperative eGFR and type of surgery (radical vs. partial), duration of ischemia, ischemia type (warm vs. cold), and tumor size. With a median follow-up of 26 months, 1,379 patients were identified from the Canadian Kidney Cancer Information System database including 665 and 714 who underwent partial and radical nephrectomy, respectively. Patients undergoing radical nephrectomy had a lower eGFR (mean = 19ml/min/1.73m 2 lower) at 3, 12, and 24 months postoperatively (P<0.001). Decline in renal function occurred early and remained stable throughout follow-up. A lower preoperative eGFR and increasing age were also associated with a lower postoperative eGFR (P<0.01). Ischemia type and duration were not predictive of postoperative decline in eGFR (P>0.05). Severe renal failure (eGFR<30ml/min/1.73m 2 ) developed postoperatively in 12.5% and 4.1% of radical and partial nephrectomy patients, respectively (P<0.001). After the initial postoperative decline, renal function remains stable in patients undergoing surgery for RCC. Patients undergoing radical nephrectomy have a greater long-term reduction in renal function compared with those undergoing partial nephrectomy. Ischemia duration and type are not predictive of postoperative renal function when adhering to generally short ischemia durations. Copyright © 2016 Elsevier Inc. All rights reserved.
Yao, Ning; Chen, Hemei; Lin, Huaqing; Deng, Chunhui; Zhang, Xiangmin
2008-03-21
Human serum contains a complex array of proteolytically derived peptides (serum peptidome), which contain biomarkers of preclinical screening and disease diagnosis. Recently, commercial C(8)-functionalized magnetic beads (1-10 microm) were widely applied to the separation and enrichment of peptides in human serum, prior to matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) analysis. In this work, laboratory-prepared C(8)-functionalized magnetic nanoparticles (about 50 nm) were prepared and applied to the fast separation and the enrichment of peptides from serum. At first, the C(8)-magnetic nanoparticles were synthesized by modifying amine-functionalized magnetic nanoparticles with chlorodimethyloctylsilane. These synthesized C(8)-amine-functionalized magnetic particles have excellent magnetic responsibility, high dispersibility and large surface area. Finally, the C(8)-magnetic nanoparticles were successfully applied to fast and efficient enrichment of low-abundance peptides from protein tryptic digestion and human serum followed by MALDI-TOF-MS analysis.
Glasby, Michael A; Tsirikos, Athanasios I; Henderson, Lindsay; Horsburgh, Gillian; Jordan, Brian; Michaelson, Ciara; Adams, Christopher I; Garrido, Enrique
2017-08-01
To compare measurements of motor evoked potential latency stimulated either magnetically (mMEP) or electrically (eMEP) and central motor conduction time (CMCT) made pre-operatively in conscious patients using transcranial and intra-operatively using electrical cortical stimulation before and after successful instrumentation for the treatment of adolescent idiopathic scoliosis. A group initially of 51 patients with adolescent idiopathic scoliosis aged 12-19 years was evaluated pre-operatively in the outpatients' department with transcranial magnetic stimulation. The neurophysiological data were then compared statistically with intra-operative responses elicited by transcranial electrical stimulation both before and after successful surgical intervention. MEPs were measured as the cortically evoked compound action potentials of Abductor hallucis. Minimum F-waves were measured using conventional nerve conduction methods and the lower motor neuron conduction time was calculated and this was subtracted from MEP latency to give CMCT. Pre-operative testing was well tolerated in our paediatric/adolescent patients. No neurological injury occurred in any patient in this series. There was no significant difference in the values of mMEP and eMEP latencies seen pre-operatively in conscious patients and intra-operatively in patients under anaesthetic. The calculated quantities mCMCT and eCMCT showed the same statistical correlations as the quantities mMEP and eMEP latency. The congruency of mMEP and eMEP and of mCMCT and eCMCT suggests that these measurements may be used comparatively and semi-quantitatively for the comparison of pre-, intra-, and post-operative spinal cord function in spinal deformity surgery.
Extreme magnetoresistance and SdH oscillation in compensated semimetals of NbSb2 single crystals
NASA Astrophysics Data System (ADS)
Guo, Lei; Liu, Yu-Kuai; Gao, Guan-Yin; Huang, Ye-Yu; Gao, Heng; Chen, Lei; Zhao, Weiyao; Ren, Wei; Li, Shi-Yan; Li, Xiao-Guang; Dong, Shuai; Zheng, Ren-Kui
2018-04-01
Topological semimetals represent one of the most interesting classes of materials that continue to attract worldwide interest. Here, we report magnetotransport properties of MPn2-type (M = Nb, Ta; Pn = P, As, Sb) NbSb2 single-crystal semimetals with a centrosymmetric C12/m1 space group, paramagnetic ground state, and non-saturation parabolic-like magnetoresistance. The NbSb2 crystals show metallic conductivity down to 2 K and undergo a metal-to-insulator-like transition under a magnetic field B (B ≥ 4 T) and exhibit a resistivity plateau in the low-temperature region (T ≤ 10 K), where the value of resistivity strongly depends on the magnitude and direction of the magnetic field. Upon sweeping the magnetic field from 0 to 14.5 T in the transverse configuration at T = 1.5 K, the NbSb2 crystal shows a large positive magnetoresistance (4.2 × 103% at B = 14.5 T) with Shubnikov-de Haas (SdH) oscillation. Hall measurements reveal that both the carrier compensation between electrons and holes and the high mobility and large mean free path of carriers contribute to the large magnetoresistance. Fast Fourier transform analyses of angle-resolved SdH oscillation indicate that the Fermi surface of the NbSb2 crystal is quasi-two-dimensional with three-dimensional components. These findings, together with the theoretically calculated electronic band structure obtained within the framework of density functional theory, suggest that NbSb2 is a good candidate compensated semimetal for further theoretical and experimental investigation of this family of materials.
Professional fighters brain health study: rationale and methods.
Bernick, Charles; Banks, Sarah; Phillips, Michael; Lowe, Mark; Shin, Wanyong; Obuchowski, Nancy; Jones, Stephen; Modic, Michael
2013-07-15
Repetitive head trauma is a risk factor for Alzheimer's disease and is the primary cause of chronic traumatic encephalopathy. However, little is known about the natural history of, and risk factors for, chronic traumatic encephalopathy or about means of early detection and intervention. The Professional Fighters Brain Health Study is a longitudinal study of active professional fighters (boxers and mixed martial artists), retired professional fighters, and controls matched for age and level of education. The main objective of the Professional Fighters Brain Health Study is to determine the relationships between measures of head trauma exposure and other potential modifiers and changes in brain imaging and neurological and behavioral function over time. The study is designed to extend over 5 years, and we anticipate enrollment of more than 400 boxers and mixed martial artists. Participants will undergo annual evaluations that include 3-tesla magnetic resonance imaging scanning, computerized cognitive assessments, speech analysis, surveys of mood and impulsivity, and blood sampling for genotyping and exploratory biomarker studies. Statistical models will be developed and validated to predict early and progressive changes in brain structure and function. A composite fight exposure index, developed as a summary measure of cumulative traumatic exposure, shows promise as a predictor of brain volumes and cognitive function.
NASA Astrophysics Data System (ADS)
El Grini, A.; Salmi, S.; Masrour, R.; Hamedoun, M.; Bouslykhane, K.; Marzouk, A.; Hourmatallah, A.; Benzakour, N.
2018-06-01
The Green's function theory and high-temperature series expansions technical have been developed for magnetic systems GeNi2-xCoxO4. We have applied the Green's function theory to evaluate thermal magnetization and magnetic susceptibility for different values of magnetic field and dilution x, considering all components of the magnetization when an external magnetic field is applied in (x,z)-plane. The second theory combined with the Padé approximants method for a randomly diluted Heisenberg magnet is used to deduce the magnetic phase diagram of GeNi2 - xCoxO4 systems. The critical exponents ? and ? associated with the magnetic susceptibility ? and the correlation length ξ, respectively, have been deduced. The theoretical results are compared with those given by magnetic measurements.
Magnetic behavior and spin-lattice coupling in cleavable van der Waals layered CrCl 3 crystals
McGuire, Michael A.; Clark, Genevieve; KC, Santosh; ...
2017-06-19
CrCl 3 is a layered insulator that undergoes a crystallographic phase transition below room temperature and orders antiferromagnetically at low temperature. Weak van der Waals bonding between the layers and ferromagnetic in-plane magnetic order make it a promising material for obtaining atomically thin magnets and creating van der Waals heterostructures. In this work we have grown crystals of CrCl 3, revisited the structural and thermodynamic properties of the bulk material, and explored mechanical exfoliation of the crystals. We find two distinct anomalies in the heat capacity at 14 and 17 K confirming that the magnetic order develops in two stagesmore » on cooling, with ferromagnetic correlations forming before long-range antiferromagnetic order develops between them. This scenario is supported by magnetization data. A magnetic phase diagram is constructed from the heat capacity and magnetization results. We also find an anomaly in the magnetic susceptibility at the crystallographic phase transition, indicating some coupling between the magnetism and the lattice. First-principles calculations accounting for van der Waals interactions also indicate spin-lattice coupling, and find multiple nearly degenerate crystallographic and magnetic structures consistent with the experimental observations. Lastly, we demonstrate that monolayer and few-layer CrCl 3 specimens can be produced from the bulk crystals by exfoliation, providing a path for the study of heterostructures and magnetism in ultrathin crystals down to the monolayer limit.« less
Magnetic behavior and spin-lattice coupling in cleavable van der Waals layered CrCl 3 crystals
DOE Office of Scientific and Technical Information (OSTI.GOV)
McGuire, Michael A.; Clark, Genevieve; KC, Santosh
CrCl 3 is a layered insulator that undergoes a crystallographic phase transition below room temperature and orders antiferromagnetically at low temperature. Weak van der Waals bonding between the layers and ferromagnetic in-plane magnetic order make it a promising material for obtaining atomically thin magnets and creating van der Waals heterostructures. In this work we have grown crystals of CrCl 3, revisited the structural and thermodynamic properties of the bulk material, and explored mechanical exfoliation of the crystals. We find two distinct anomalies in the heat capacity at 14 and 17 K confirming that the magnetic order develops in two stagesmore » on cooling, with ferromagnetic correlations forming before long-range antiferromagnetic order develops between them. This scenario is supported by magnetization data. A magnetic phase diagram is constructed from the heat capacity and magnetization results. We also find an anomaly in the magnetic susceptibility at the crystallographic phase transition, indicating some coupling between the magnetism and the lattice. First-principles calculations accounting for van der Waals interactions also indicate spin-lattice coupling, and find multiple nearly degenerate crystallographic and magnetic structures consistent with the experimental observations. Lastly, we demonstrate that monolayer and few-layer CrCl 3 specimens can be produced from the bulk crystals by exfoliation, providing a path for the study of heterostructures and magnetism in ultrathin crystals down to the monolayer limit.« less
Kappa-Electrons Downstream of the Solar Wind Termination Shock
NASA Astrophysics Data System (ADS)
Fahr, H. J.
2017-12-01
A theoretical description of the solar wind electron distribution function downstream of the termination shock under the influence of the shock-induced injection of overshooting KeV-energetic electrons will be presented. A kinetic phasespace transport equation in the bulk frame of the heliosheath plasma flow is developed for the solar wind electrons, taking into account shock-induced electron injection, convective changes, magnetic cooling processes and whistler wave-induced energy diffusion. Assuming that the local electron distribution under the prevailing Non-LTE conditions can be represented by a local kappa function with a local kappa parameter that varies with the streamline coordinates, we determine the parameters of the resulting, initial kappa distribution for the downstream electrons. From this initial function spectral electron fluxes can be derived and can be compared with those measured by the VOYAGER-1 spacecraft in the range between 40 to 70 KeV. It can then be shown that with kappa values around kappa = 6 one can in fact fit these data very satisfactorily. In addition it is shown that for isentropic electron flows kappa-distributed electrons have to undergo simultaneous changes of both parameters, i.e. kappa and theta, of the electron kappa function. It is also shown then that under the influence of energy sinks and sources the electron flux becomes non-isentropic with electron entropies changing along the streamline.
Microfluidic separation of magnetic nanoparticles on an ordered array of magnetized micropillars
NASA Astrophysics Data System (ADS)
Orlandi, G.; Kuzhir, P.; Izmaylov, Y.; Alves Marins, J.; Ezzaier, H.; Robert, L.; Doutre, F.; Noblin, X.; Lomenech, C.; Bossis, G.; Meunier, A.; Sandoz, G.; Zubarev, A.
2016-06-01
Microfluidic separation of magnetic particles is based on their capture by magnetized microcollectors while the suspending fluid flows past the microcollectors inside a microchannel. Separation of nanoparticles is often challenging because of strong Brownian motion. Low capture efficiency of nanoparticles limits their applications in bioanalysis. However, at some conditions, magnetic nanoparticles may undergo field-induced aggregation that amplifies the magnetic attractive force proportionally to the aggregate volume and considerably increases nanoparticle capture efficiency. In this paper, we have demonstrated the role of such aggregation on an efficient capture of magnetic nanoparticles (about 80 nm in diameter) in a microfluidic channel equipped with a nickel micropillar array. This array was magnetized by an external uniform magnetic field, of intensity as low as 6-10 kA/m, and experiments were carried out at flow rates ranging between 0.3 and 30 μ L /min . Nanoparticle capture is shown to be mostly governed by the Mason number Ma, while the dipolar coupling parameter α does not exhibit a clear effect in the studied range, 1.4 < α < 4.5. The capture efficiency Λ shows a strongly decreasing Mason number behavior, Λ ∝M a-1.78 within the range 32 ≤ Ma ≤ 3250. We have proposed a simple theoretical model which considers destructible nanoparticle chains and gives the scaling behavior, Λ ∝M a-1.7 , close to the experimental findings.
Bioactive films of zein/magnetite magnetically stimuli-responsive for controlled drug release
NASA Astrophysics Data System (ADS)
Marín, Tíffany; Montoya, Paula; Arnache, Oscar; Pinal, Rodolfo; Calderón, Jorge
2018-07-01
The Zein films in two configurations with magnetite nanoparticles (zein/NPs) and magnetite-acetaminophen (zein/NPs/Drug) were used as magnetically stimuli-responsive systems to propose a model of controlled release by dissolution and diffusion mechanism. Composite material films of zein/NPs and zein/NPs/Drug were made by dispersion of magnetite nanoparticles into zein solution then solvent casting of the solution on a flat Teflon substrate. The properties of composite films were analyzed by magnetization curves of (MvsH) and measurements of magnetic force microscopy (MFM). Drug release from the zein/NPs/Drug composite films was determined using a type II dissolution apparatus for a period of 2 h under applied magnetic field conditions. In addition, the diffusion mechanism was tested with zein/NPs films into diffusion cell containing acetaminophen solution for 24 h and using a permanent magnet as a remote trigger device. The results showed that the magnetite nanoparticles contained in the zein/NPs and zein/NPs/Drug composite films are stable, i.e., they do not undergo sufficiently high levels of oxidation as to alter their magnetic properties. Furthermore, the dissolution and diffusion results lead us to conclude that zein composite films effectively behave as stimuli-responsive systems triggered by an external magnetic field applied. The result is a model controlled release system whereby drug release can be controlled by adjusting the magnitude of the applied magnetic field.
Functional Magnetic Resonance Imaging in Alzheimer' Disease Drug Development.
Holiga, Stefan; Abdulkadir, Ahmed; Klöppel, Stefan; Dukart, Juergen
2018-01-01
While now commonly applied for studying human brain function the value of functional magnetic resonance imaging in drug development has only recently been recognized. Here we describe the different functional magnetic resonance imaging techniques applied in Alzheimer's disease drug development with their applications, implementation guidelines, and potential pitfalls.
Prenatal and accurate perinatal diagnosis of type 2 H or ductular duplicate gallbladder.
Maggi, Umberto; Farris, Giorgio; Carnevali, Alessandra; Borzani, Irene; Clerici, Paola; Agosti, Massimo; Rossi, Giorgio; Leva, Ernesto
2018-02-07
Double gallbladder is a rare biliary anomaly. Perinatal diagnosis of the disorder has been reported in only 6 cases, and in 5 of them the diagnosis was based on ultrasound imaging only. However, the ultrasound technique alone does not provide a sufficiently precise description of cystic ducts and biliary anatomy, an information that is crucial for a correct classification and for a possible future surgery. At 21 weeks of gestational age of an uneventful pregnancy in a 38 year old primipara mother, a routine ultrasound screening detected a biliary anomaly in the fetus suggestive of a double gallbladder. A neonatal abdominal ultrasonography performed on postnatal day 2 confirmed the diagnosis. On day 12 the newborn underwent a Magnetic Resonance Cholangiopancreatography (MRCP) that clearly characterized the anatomy of the anomaly: both gallbladders had their own cystic duct and both had a separate insertion in the main biliary duct. We report a case of early prenatal suspected duplicate gallbladder that was confirmed by a neonatal precise diagnosis of a Type 2, H or ductular duplicate gallbladder, using for the first time 3D images of Magnetic resonance cholangiopancreatography in a newborn. An accurate anatomical diagnosis is mandatory in patients undergoing a possible future cholecystectomy, to avoid surgical complications or reoperations. Therefore, in case of a perinatal suspicion of a double gallbladder, neonates should undergo a Magnetic resonance cholangiopancreatography. A review of the Literature about this variant is included.
Størmer, Fredrik C
2015-04-01
When cryptochrome in the retina is exposed to blue light, it undergo series of complicated chemical reactions. One of these intermediates has magnetic properties. It could be a link between the magnetic stage of cryptochrome in the retina and magnetite in the brain. A disturbance in this system could be involved in the development of frontotemporal dementia and other mental disturbances like Alzheimer's disease. There could also be a link between circadian rhythms and memory dysfunction connected to schizophrenia, type 2 diabetes, and blue light. Copyright © 2015 Elsevier Ltd. All rights reserved.
Interventional-Cardiovascular MR: Role of the Interventional MR Technologist
Mazal, Jonathan R; Rogers, Toby; Schenke, William H; Faranesh, Anthony Z; Hansen, Michael; O’Brien, Kendall; Ratnayaka, Kanishka; Lederman, Robert J
2016-01-01
Background Interventional-cardiovascular magnetic resonance (iCMR) is a promising clinical tool for adults and children who need a comprehensive hemodynamic catheterization of the heart. Magnetic resonance (MR) imaging-guided cardiac catheterization offers radiation-free examination with increased soft tissue contrast and unconstrained imaging planes for catheter guidance. The interventional MR technologist plays an important role in the care of patients undergoing such procedures. It is therefore helpful for technologists to under-stand the unique iCMR preprocedural preparation, procedural and imaging workflows, and management of emergencies. The authors report their team’s experience from the National Institutes of Health Clinical Center and a collaborating pediatric site. PMID:26721838
Spontaneous and superfluid chiral edge states in exciton-polariton condensates
NASA Astrophysics Data System (ADS)
Sigurdsson, H.; Li, G.; Liew, T. C. H.
2017-09-01
We present a scheme of interaction-induced topological band structures based on the spin anisotropy of exciton-polaritons in semiconductor microcavities. We predict theoretically that this scheme allows the engineering of topological gaps, without requiring a magnetic field or strong spin-orbit interaction (transverse electric-transverse magnetic splitting). Under nonresonant pumping we find that an initially topologically trivial system undergoes a topological transition upon the spontaneous breaking of phase symmetry associated with polariton condensation. Under either nonresonant or resonant coherent pumping we find that it is also possible to engineer a topological dispersion that is linear in wave vector—a property associated with polariton superfluidity.
NASA Astrophysics Data System (ADS)
Matsubayashi, K.; Hirayama, T.; Yamashita, T.; Ohara, S.; Kawamura, N.; Mizumaki, M.; Ishimatsu, N.; Watanabe, S.; Kitagawa, K.; Uwatoko, Y.
2015-02-01
We report electrical resistivity, ac magnetic susceptibility, and x-ray absorption spectroscopy measurements of intermediate valence YbNi3Ga9 under pressure and magnetic field. We have revealed a characteristic pressure-induced Yb valence crossover within the temperature-pressure phase diagram, and a first-order metamagnetic transition is found below Pc˜9 GPa where the system undergoes a pressure-induced antiferromagnetic transition. As a possible origin of the metamagnetic behavior, a critical valence fluctuation emerging near the critical point of the first-order valence transition is discussed on the basis of the temperature-field-pressure phase diagram.
Direct magnetocaloric characterization and simulation of thermomagnetic cycles
NASA Astrophysics Data System (ADS)
Porcari, G.; Buzzi, M.; Cugini, F.; Pellicelli, R.; Pernechele, C.; Caron, L.; Brück, E.; Solzi, M.
2013-07-01
An experimental setup for the direct measurement of the magnetocaloric effect capable of simulating high frequency magnetothermal cycles on laboratory-scale samples is described. The study of the magnetocaloric properties of working materials under operative conditions is fundamental for the development of innovative devices. Frequency and time dependent characterization can provide essential information on intrinsic features such as magnetic field induced fatigue in materials undergoing first order magnetic phase transitions. A full characterization of the adiabatic temperature change performed for a sample of Gadolinium across its Curie transition shows the good agreement between our results and literature data and in-field differential scanning calorimetry.
Elastic Constants of Ni-Mn-Ga Magnetic Shape Memory Alloys
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stipcich, M.; Manosa, L.; Planes, A.
2004-01-01
We have measured the adiabatic second order elastic constants of two Ni-Mn-Ga magnetic shape memory crystals with different martensitic transition temperatures, using ultrasonic methods. The temperature dependence of the elastic constants has been followed across the ferromagnetic transition and down to the martensitic transition temperature. Within experimental errors no noticeable change in any of the elastic constants has been observed at the Curie point. The temperature dependence of the shear elastic constant C' has been found to be very different for the two alloys. Such a different behavior is in agreement with recent theoretical predictions for systems undergoing multi-stage structuralmore » transitions.« less
NASA Astrophysics Data System (ADS)
Zhang, Linfang; Wang, Jingmin; Hua, Hui; Jiang, Chengbao; Xu, Huibin
2014-09-01
Some off-stoichiometric Ni-Mn-Ga alloys undergo a coupled magnetostructural transition from ferromagnetic martensite to paramagnetic austenite, giving rise to the large magnetocaloric effect. However, the magnetostructural transitions of Ni-Mn-Ga alloys generally take place at temperatures higher than room temperature. Here, we report that by the partial substitution of In for Ga, the paramagnetic austenite phase is well stabilized, and the magnetostructural transition can be tailored around room temperature. Sizable magnetic entropy change and adiabatic temperature change were induced by magnetic field change in the vicinity of the magnetostructural transition of the In-doped Ni-Mn-Ga alloys.
Inspiratory Muscle Training and Functional Capacity in Patients Undergoing Cardiac Surgery.
Cordeiro, André Luiz Lisboa; de Melo, Thiago Araújo; Neves, Daniela; Luna, Julianne; Esquivel, Mateus Souza; Guimarães, André Raimundo França; Borges, Daniel Lago; Petto, Jefferson
2016-04-01
Cardiac surgery is a highly complex procedure which generates worsening of lung function and decreased inspiratory muscle strength. The inspiratory muscle training becomes effective for muscle strengthening and can improve functional capacity. To investigate the effect of inspiratory muscle training on functional capacity submaximal and inspiratory muscle strength in patients undergoing cardiac surgery. This is a clinical randomized controlled trial with patients undergoing cardiac surgery at Instituto Nobre de Cardiologia. Patients were divided into two groups: control group and training. Preoperatively, were assessed the maximum inspiratory pressure and the distance covered in a 6-minute walk test. From the third postoperative day, the control group was managed according to the routine of the unit while the training group underwent daily protocol of respiratory muscle training until the day of discharge. 50 patients, 27 (54%) males were included, with a mean age of 56.7±13.9 years. After the analysis, the training group had significant increase in maximum inspiratory pressure (69.5±14.9 vs. 83.1±19.1 cmH2O, P=0.0073) and 6-minute walk test (422.4±102.8 vs. 502.4±112.8 m, P=0.0031). We conclude that inspiratory muscle training was effective in improving functional capacity submaximal and inspiratory muscle strength in this sample of patients undergoing cardiac surgery.
The Role of Cortical Plasticity in Recovery of Function Following Allogeneic Hand Transplantation
2015-10-01
transplantation, functional magnetic resonance imaging, hand replantation, cortical reorganization, functional recovery 16. SECURITY CLASSIFICATION OF: U...functional magnetic resonance imaging (fMRI) data suggest that areas of the sensory and motor cortex devoted to representing the hand prior to...function, recovery, functional magnetic resonance imaging 3. Accomplishments Major Goals Achieved: Year Two My lab is relocated to Washington University
Zhang, Ru; Duan, Yuanfeng; Or, Siu Wing; Zhao, Yang
2014-01-01
An elasto-magnetic (EM) and magneto-electric (ME) effect based elasto-magneto-electric (EME) sensor has been proposed recently by the authors for stress monitoring of steel cables with obvious superiorities over traditional elasto-magnetic sensors. For design optimization and engineering application of the EME sensor, the design theory is interpreted with a developed model taking into account the EM coupling effect and ME coupling effect. This model is able to approximate the magnetization changes that a steel structural component undergoes when subjected to excitation magnetic field and external stress, and to simulate the induced ME voltages of the ME sensing unit located in the magnetization area. A full-scale experiment is then carried out to verify the model and to calibrate the EME sensor as a non-destructive evaluation (NDE) tool to monitor the cable stress. The experimental results agree well with the simulation results using the developed model. The proposed EME sensor proves to be feasible for stress monitoring of steel cables with high sensitivity, fast response, and ease of installation. PMID:25072348
Mechanocaloric effects in shape memory alloys.
Mañosa, Lluís; Planes, Antoni
2016-08-13
Shape memory alloys (SMA) are a class of ferroic materials which undergo a structural (martensitic) transition where the associated ferroic property is a lattice distortion (strain). The sensitiveness of the transition to the conjugated external field (stress), together with the latent heat of the transition, gives rise to giant mechanocaloric effects. In non-magnetic SMA, the lattice distortion is mostly described by a pure shear and the martensitic transition in this family of alloys is strongly affected by uniaxial stress, whereas it is basically insensitive to hydrostatic pressure. As a result, non-magnetic alloys exhibit giant elastocaloric effects but negligible barocaloric effects. By contrast, in a number of magnetic SMA, the lattice distortion at the martensitic transition involves a volume change in addition to the shear strain. Those alloys are affected by both uniaxial stress and hydrostatic pressure and they exhibit giant elastocaloric and barocaloric effects. The paper aims at providing a critical survey of available experimental data on elastocaloric and barocaloric effects in magnetic and non-magnetic SMA.This article is part of the themed issue 'Taking the temperature of phase transitions in cool materials'. © 2016 The Author(s).
Zhang, Ru; Duan, Yuanfeng; Or, Siu Wing; Zhao, Yang
2014-07-28
An elasto-magnetic (EM) and magneto-electric (ME) effect based elasto-magneto-electric (EME) sensor has been proposed recently by the authors for stress monitoring of steel cables with obvious superiorities over traditional elasto-magnetic sensors. For design optimization and engineering application of the EME sensor, the design theory is interpreted with a developed model taking into account the EM coupling effect and ME coupling effect. This model is able to approximate the magnetization changes that a steel structural component undergoes when subjected to excitation magnetic field and external stress, and to simulate the induced ME voltages of the ME sensing unit located in the magnetization area. A full-scale experiment is then carried out to verify the model and to calibrate the EME sensor as a non-destructive evaluation (NDE) tool to monitor the cable stress. The experimental results agree well with the simulation results using the developed model. The proposed EME sensor proves to be feasible for stress monitoring of steel cables with high sensitivity, fast response, and ease of installation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hope, Kevin M.; Samudrala, Gopi K.; Vohra, Yogesh K.
The atomic volume of rare earth metal Dysprosium (Dy) has been measured up to high pressures of 35 GPa and low temperatures between 200 K and 7 K in a diamond anvil cell using angle dispersive x-ray diffraction at a synchrotron source. The hexagonal close-packed (hcp), alpha-Samarium (α-Sm), and double hexagonal close packed (dhcp) phases are observed to be stable in Dy under high-pressure and low-temperature conditions achieved in our experiments. Dy is known to undergo magnetic ordering below 176 K at ambient pressure with magnetic ordering Néel temperature (T N) that changes rapidly with increasing pressure. Our experimental measurementmore » shows that Dy has near-zero thermal expansion in the magnetically ordered state and normal thermal expansion in the paramagnetic state for all the three known high pressure phases (hcp, α-Sm, and dhcp) to 35 GPa. This near-zero thermal expansion behavior in Dy is observed below the magnetic ordering temperature T N at all pressures up to 35 GPa.« less
NASA Astrophysics Data System (ADS)
Fitzpatrick, Richard
2017-12-01
An investigation is made into the interaction of a magnetic island chain, embedded in a tokamak plasma, with an externally generated magnetic perturbation of the same helicity whose helical phase is rapidly oscillating. The analysis is similar in form to the classic analysis used by Kapitza [Sov. Phys. JETP 21, 588 (1951)] to examine the angular motion of a rigid pendulum whose pivot point undergoes rapid vertical oscillations. The phase oscillations are found to modify the existing terms, and also to give rise to new terms, in the equations governing the secular evolution of the island chain's radial width and helical phase. An examination of the properties of the new secular evolution equation reveals that it is possible to phase-lock an island chain to an external magnetic perturbation with an oscillating helical phase in a stabilizing phase relation provided that the amplitude, ɛ, of the phase oscillations (in radians) is such that |J0(ɛ )|≪1 , and the mean angular frequency of the perturbation closely matches the natural angular frequency of the island chain.
Galactic Cosmic-Ray Anistropy During the Forbush Decrease Starting 2013 April 13
NASA Astrophysics Data System (ADS)
Tortermpun, U.; Ruffolo, D.; Bieber, J. W.
2018-01-01
The flux of Galactic cosmic rays (GCRs) can undergo a Forbush decrease (FD) during the passage of a shock, sheath region, or magnetic flux rope associated with a coronal mass ejection (CME). Cosmic-ray observations during FDs can provide information complementary to in situ observations of the local plasma and magnetic field, because cosmic-ray distributions allow remote sensing of distant conditions. Here we develop techniques to determine the GCR anisotropy before and during an FD using data from the worldwide network of neutron monitors, for a case study of the FD starting on 2013 April 13. We find that at times with strong magnetic fluctuations and strong cosmic-ray scattering, there were spikes of high perpendicular anisotropy and weak parallel anisotropy. In contrast, within the CME flux rope there was a strong parallel anisotropy in the direction predicted from a theory of drift motions into one leg of the magnetic flux rope and out the other, confirming that the anisotropy can remotely sense a large-scale flow of GCRs through a magnetic flux structure.
Hope, Kevin M.; Samudrala, Gopi K.; Vohra, Yogesh K.
2017-01-01
The atomic volume of rare earth metal Dysprosium (Dy) has been measured up to high pressures of 35 GPa and low temperatures between 200 K and 7 K in a diamond anvil cell using angle dispersive x-ray diffraction at a synchrotron source. The hexagonal close-packed (hcp), alpha-Samarium (α-Sm), and double hexagonal close packed (dhcp) phases are observed to be stable in Dy under high-pressure and low-temperature conditions achieved in our experiments. Dy is known to undergo magnetic ordering below 176 K at ambient pressure with magnetic ordering Néel temperature (T N) that changes rapidly with increasing pressure. Our experimental measurementmore » shows that Dy has near-zero thermal expansion in the magnetically ordered state and normal thermal expansion in the paramagnetic state for all the three known high pressure phases (hcp, α-Sm, and dhcp) to 35 GPa. This near-zero thermal expansion behavior in Dy is observed below the magnetic ordering temperature T N at all pressures up to 35 GPa.« less
Mechanocaloric effects in shape memory alloys
2016-01-01
Shape memory alloys (SMA) are a class of ferroic materials which undergo a structural (martensitic) transition where the associated ferroic property is a lattice distortion (strain). The sensitiveness of the transition to the conjugated external field (stress), together with the latent heat of the transition, gives rise to giant mechanocaloric effects. In non-magnetic SMA, the lattice distortion is mostly described by a pure shear and the martensitic transition in this family of alloys is strongly affected by uniaxial stress, whereas it is basically insensitive to hydrostatic pressure. As a result, non-magnetic alloys exhibit giant elastocaloric effects but negligible barocaloric effects. By contrast, in a number of magnetic SMA, the lattice distortion at the martensitic transition involves a volume change in addition to the shear strain. Those alloys are affected by both uniaxial stress and hydrostatic pressure and they exhibit giant elastocaloric and barocaloric effects. The paper aims at providing a critical survey of available experimental data on elastocaloric and barocaloric effects in magnetic and non-magnetic SMA. This article is part of the themed issue ‘Taking the temperature of phase transitions in cool materials’. PMID:27402931
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chatterjee, Gourab, E-mail: gourab@tifr.res.in; Singh, Prashant Kumar; Adak, Amitava
A pump-probe polarimetric technique is demonstrated, which provides a complete, temporally and spatially resolved mapping of the megagauss magnetic fields generated in intense short-pulse laser-plasma interactions. A normally incident time-delayed probe pulse reflected from its critical surface undergoes a change in its ellipticity according to the magneto-optic Cotton-Mouton effect due to the azimuthal nature of the ambient self-generated megagauss magnetic fields. The temporal resolution of the magnetic field mapping is typically of the order of the pulsewidth, limited by the laser intensity contrast, whereas a spatial resolution of a few μm is achieved by this optical technique. High-harmonics of themore » probe can be employed to penetrate deeper into the plasma to even near-solid densities. The spatial and temporal evolution of the megagauss magnetic fields at the target front as well as at the target rear are presented. The μm-scale resolution of the magnetic field mapping provides valuable information on the filamentary instabilities at the target front, whereas probing the target rear mirrors the highly complex fast electron transport in intense laser-plasma interactions.« less
Doping Evolution of Magnetic Order and Magnetic Excitations in (Sr1 -xLax)3Ir2O7
NASA Astrophysics Data System (ADS)
Lu, Xingye; McNally, D. E.; Moretti Sala, M.; Terzic, J.; Upton, M. H.; Casa, D.; Ingold, G.; Cao, G.; Schmitt, T.
2017-01-01
We use resonant elastic and inelastic x-ray scattering at the Ir-L3 edge to study the doping-dependent magnetic order, magnetic excitations, and spin-orbit excitons in the electron-doped bilayer iridate (Sr1 -xLax )3Ir2 O7 (0 ≤x ≤0.065 ). With increasing doping x , the three-dimensional long range antiferromagnetic order is gradually suppressed and evolves into a three-dimensional short range order across the insulator-to-metal transition from x =0 to 0.05, followed by a transition to two-dimensional short range order between x =0.05 and 0.065. Because of the interactions between the Jeff=1/2 pseudospins and the emergent itinerant electrons, magnetic excitations undergo damping, anisotropic softening, and gap collapse, accompanied by weakly doping-dependent spin-orbit excitons. Therefore, we conclude that electron doping suppresses the magnetic anisotropy and interlayer couplings and drives (Sr1 -xLax )3Ir2 O7 into a correlated metallic state with two-dimensional short range antiferromagnetic order. Strong antiferromagnetic fluctuations of the Jeff=1/2 moments persist deep in this correlated metallic state, with the magnon gap strongly suppressed.
Schmit, P F; Knapp, P F; Hansen, S B; Gomez, M R; Hahn, K D; Sinars, D B; Peterson, K J; Slutz, S A; Sefkow, A B; Awe, T J; Harding, E; Jennings, C A; Chandler, G A; Cooper, G W; Cuneo, M E; Geissel, M; Harvey-Thompson, A J; Herrmann, M C; Hess, M H; Johns, O; Lamppa, D C; Martin, M R; McBride, R D; Porter, J L; Robertson, G K; Rochau, G A; Rovang, D C; Ruiz, C L; Savage, M E; Smith, I C; Stygar, W A; Vesey, R A
2014-10-10
Magnetizing the fuel in inertial confinement fusion relaxes ignition requirements by reducing thermal conductivity and changing the physics of burn product confinement. Diagnosing the level of fuel magnetization during burn is critical to understanding target performance in magneto-inertial fusion (MIF) implosions. In pure deuterium fusion plasma, 1.01 MeV tritons are emitted during deuterium-deuterium fusion and can undergo secondary deuterium-tritium reactions before exiting the fuel. Increasing the fuel magnetization elongates the path lengths through the fuel of some of the tritons, enhancing their probability of reaction. Based on this feature, a method to diagnose fuel magnetization using the ratio of overall deuterium-tritium to deuterium-deuterium neutron yields is developed. Analysis of anisotropies in the secondary neutron energy spectra further constrain the measurement. Secondary reactions also are shown to provide an upper bound for the volumetric fuel-pusher mix in MIF. The analysis is applied to recent MIF experiments [M. R. Gomez et al., Phys. Rev. Lett. 113, 155003 (2014)] on the Z Pulsed Power Facility, indicating that significant magnetic confinement of charged burn products was achieved and suggesting a relatively low-mix environment. Both of these are essential features of future ignition-scale MIF designs.
Magnetic and thermodynamic properties of Nd3NiGe2
NASA Astrophysics Data System (ADS)
Matsumoto, Keisuke T.; Hiraoka, Koichi
2018-05-01
We here report the magnetization, M, and specific heat, C, of Nd3NiGe2 , which crystallizes in the orthorhombic Gd3NiSi2 -type structure. Nd ions occupy three nonequivalent sites in a unit cell. Upon cooling, magnetization divided by magnetic field, M / B , increased sharply at the Curie temperature, TC, of 87 K and below 40 K. The former result indicates that the increase in M / B observed at TC is due to the long-range ferromagnetic order. The increase below 40 K is derived from a short-range correlation because of the absence of clear anomaly in C (T) . At 10 K and 2 K, the values of M undergo metamagnetic transitions. The value of magnetic specific heat divided by temperature shows a shoulder-like anomaly at around 20 K, which is attributed to antiferromagnetic behavior. Furthermore, two peaks in C (T) were observed at 4.5 K and 3.8 K, and these peaks occurred at lower temperatures in the presence of a magnetic field. This behavior is typical of materials with antiferromagnetic order. These observations are attributed to the competition between ferromagnetic and antiferromagnetic interactions, which is a result of the three nonequivalent Nd sites.
Kohn, Gabriel; Hicho, George; Swartzendruber, Lydon
1997-01-01
A steel hardness measurement system and method of using same are provided for measuring at least one mechanical or magnetic characteristic of a ferromagnetic sample as a function of at least one magnetic characteristic of the sample. A magnetic field generator subjects the sample to a variable external magnetic field. The magnetic field intensity of the magnetic field generated by the magnetic field generating means is measured and a signal sensor is provided for measuring Barkhausen signals from the sample when the sample is subjected to the external magnetic field. A signal processing unit calculates a jump sum rate first moment as a function of the Barkhausen signals measured by the signal sensor and the magnetic field intensity, and for determining the at least one mechanical or magnetic characteristic as a function of the jump sum rate first moment.
Kohn, G.; Hicho, G.; Swartzendruber, L.
1997-04-08
A steel hardness measurement system and method of using same are provided for measuring at least one mechanical or magnetic characteristic of a ferromagnetic sample as a function of at least one magnetic characteristic of the sample. A magnetic field generator subjects the sample to a variable external magnetic field. The magnetic field intensity of the magnetic field generated by the magnetic field generating means is measured and a signal sensor is provided for measuring Barkhausen signals from the sample when the sample is subjected to the external magnetic field. A signal processing unit calculates a jump sum rate first moment as a function of the Barkhausen signals measured by the signal sensor and the magnetic field intensity, and for determining the at least one mechanical or magnetic characteristic as a function of the jump sum rate first moment. 7 figs.
NASA Astrophysics Data System (ADS)
Gao, Bo; Yao, Jinli; Xue, Desheng
2010-09-01
Prussian blue analogue Fe II1.1Cr IIx[Cr III(CN) 6] 0.6- x· nH 2O nanowires were synthesized by electrodeposition. The magnetic properties investigation indicates that the nanowires exhibit cluster spin-glass behavior, which undergoes a magnetic transition to a frozen state below about 62 K. Spin disorder arising from reduced coordination and broken exchange bonds between spin centers due to the structural defects may be the reason that causes the spin-glass freezing behavior. The negative magnetization observed at temperature lower than the compensation temperature ( Tcomp˜43 K) at a field of 10 Oe may be due to the different temperature dependences of the ferromagnetic site Fe-Cr and antiferromagnetic site Cr-Cr.
NASA Astrophysics Data System (ADS)
Corrêa, Emerson B. S.; Linhares, César A.; Malbouisson, Adolfo P. C.
2018-03-01
We present a model to study the effects from external magnetic field, chemical potential and finite size on the phase structures of a massive four- and six-fermion interacting systems. These effects are introduced by a method of compactification of coordinates, a generalization of the standard Matsubara prescription. Through the compactification of the z-coordinate and of imaginary time, we describe a heated system with the shape of a film of thickness L, at temperature β-1 undergoing first- or second-order phase transition. We have found a strong dependence of the temperature transition on the coupling constants λ and η. Besides inverse magnetic catalysis and symmetry breaking for both kinds of transition, we have found an inverse symmetry breaking phenomenon with respect to first-order phase transition.
Li, Ying; Liu, Yi; Gao, Tieren; Zhang, Boce; Song, Yingying; Terrell, Jessica L; Barber, Nathan; Bentley, William E; Takeuchi, Ichiro; Payne, Gregory F; Wang, Qin
2015-05-20
A magnetic nanocomposite film with the capability of reversibly collecting functionalized magnetic particles was fabricated by simultaneously imposing two orthogonal stimuli (electrical and magnetic). We demonstrate that cathodic codeposition of chitosan and Fe3O4 nanoparticles while simultaneously applying a magnetic field during codeposition can (i) organize structure, (ii) confer magnetic properties, and (iii) yield magnetic films that can perform reversible collection/assembly functions. The magnetic field triggered the self-assembly of Fe3O4 nanoparticles into hierarchical "chains" and "fibers" in the chitosan film. For controlled magnetic properties, the Fe3O4-chitosan film was electrodeposited in the presence of various strength magnetic fields and different deposition times. The magnetic properties of the resulting films should enable broad applications in complex devices. As a proof of concept, we demonstrate the reversible capture and release of green fluorescent protein (EGFP)-conjugated magnetic microparticles by the magnetic chitosan film. Moreover, antibody-functionalized magnetic microparticles were applied to capture cells from a sample, and these cells were collected, analyzed, and released by the magnetic chitosan film, paving the way for applications such as reusable biosensor interfaces (e.g., for pathogen detection). To our knowledge, this is the first report to apply a magnetic field during the electrodeposition of a hydrogel to generate magnetic soft matter. Importantly, the simple, rapid, and reagentless fabrication methodologies demonstrated here are valuable features for creating a magnetic device interface.
Dodin, Dmitry V; Ivanov, Anatoly I; Burshtein, Anatoly I
2012-07-14
The fluorescence of the photoexcited electron acceptor, (1)A∗, and the exciplex, (1)[D(+δ)A(-δ)] formed at contact of (1)A∗ with an electron donor (1)D, is known to be very sensitive to a magnetic field, assisting the spin conversion in the resulting geminate radical ion pair (RIP), (1, 3)[D(+)...A(-)]. The relative increase of the fluorescence in the highest magnetic field compared to the lowest one, known as the magnetic field effect, crucially depends on the dielectric constant of the solvent, ɛ. This phenomenon first studied experimentally is at first reproduced here theoretically by means of the so called integral encounter theory. It was shown to be very sensitive to the position of the exciplex energy level relative to the levels of exciplex precursors and the charged products of its dissociation. The results obtained strongly depend on the dielectric properties of the solvents as well as on the exciplex and RIP formation rates.
Manipulation of positron orbits in a dipole magnetic field with fluctuating electric fields
NASA Astrophysics Data System (ADS)
Saitoh, H.; Horn-Stanja, J.; Nißl, S.; Stenson, E. V.; Hergenhahn, U.; Pedersen, T. Sunn; Singer, M.; Dickmann, M.; Hugenschmidt, C.; Stoneking, M. R.; Danielson, J. R.; Surko, C. M.
2018-01-01
We report the manipulation of positron orbits in a toroidal dipole magnetic field configuration realized with electric fields generated by segmented electrodes. When the toroidal circulation motion of positrons in the dipole field is coupled with time-varying electric fields generated by azimuthally segmented outer electrodes, positrons undergo oscillations of their radial positions. This enables quick manipulation of the spatial profiles of positrons in a dipole field trap by choosing appropriate frequency, amplitude, phase, and gating time of the electric fields. According to numerical orbit analysis, we applied these electric fields to positrons injected from the NEPOMUC slow positron facility into a prototype dipole field trap experiment with a permanent magnet. Measurements with annihilation γ-rays clearly demonstrated the efficient compression effects of positrons into the strong magnetic field region of the dipole field configuration. This positron manipulation technique can be used as one of essential tools for future experiments on the formation of electron-positron plasmas.
Heat capacity peak at the quantum critical point of the transverse Ising magnet CoNb2O6
Liang, Tian; Koohpayeh, S. M.; Krizan, J. W.; McQueen, T. M.; Cava, R. J.; Ong, N. P.
2015-01-01
The transverse Ising magnet Hamiltonian describing the Ising chain in a transverse magnetic field is the archetypal example of a system that undergoes a transition at a quantum critical point (QCP). The columbite CoNb2O6 is the closest realization of the transverse Ising magnet found to date. At low temperatures, neutron diffraction has observed a set of discrete collective spin modes near the QCP. Here, we ask if there are low-lying spin excitations distinct from these relatively high-energy modes. Using the heat capacity, we show that a significant band of gapless spin excitations exists. At the QCP, their spin entropy rises to a prominent peak that accounts for 30% of the total spin degrees of freedom. In a narrow field interval below the QCP, the gapless excitations display a fermion-like, temperature-linear heat capacity below 1 K. These novel gapless modes are the main spin excitations participating in, and affected by, the quantum transition. PMID:26146018
Investigation of the Possibility of Using Nuclear Magnetic Spin Alignment
NASA Technical Reports Server (NTRS)
Dent, William V., Jr.
1998-01-01
The goal of the program to investigate a "Gasdynamic fusion propulsion system for space exploration" is to develop a fusion propulsion system for a manned mission to the planet mars. A study using Deuterium and Tritium atoms are currently in progress. When these atoms under-go fusion, the resulting neutrons and alpha particles are emitted in random directions (isotropically). The probable direction of emission is equal for all directions, thus resulting in wasted energy, massive shielding and cooling requirements, and serious problems with the physics of achieving fusion. If the nuclear magnetic spin moments of the deuterium and tritium nuclei could be precisely aligned at the moment of fusion, the stream of emitted neutrons could be directed out the rear of the spacecraft for thrust and the alpha particles directed forward into an electromagnet ot produce electricity to continue operating the fusion engine. The following supporting topics are discussed: nuclear magnetic moments and spin precession in magnetic field, nuclear spin quantum mechanics, kinematics of nuclear reactions, and angular distribution of particles.
Parshall, D.; Pintschovius, L.; Niedziela, Jennifer L.; ...
2015-04-27
Pmore » arent compounds of Fe-based superconductors undergo a structural phase transition from a tetragonal to an orthorhombic structure. We investigated the temperature dependence of the frequencies of TA phonons that extrapolate to the shear vibrational mode at the zone center, which corresponds to the orthorhombic deformation of the crystal structure at low temperatures in BaFe 2 As 2 and SrFe 2 As 2 . We found that acoustic phonons at small wave vectors soften gradually towards the transition from high temperatures, tracking the increase of the size of slowly fluctuating magnetic domains. On cooling below the transition to base temperature the phonons harden, following the square of the magnetic moment (which we find is proportional to the anisotropy gap). Finally, our results provide evidence for close correlation between magnetic and phonon properties in Fe-based superconductors.« less
Pioneer 10 and 11 (Jupiter and Saturn) magnetic field experiments
NASA Technical Reports Server (NTRS)
Jones, D. E.
1986-01-01
Magnet field data obtained by the vector helium magnetometer (VHM) during the encounters of Jupiter (Pioneer 10 and 11) and Saturn (Pioneer 11) was analyzed and interpreted. The puzzling characteristics of the Jovian and Saturnian magnetospheric magnetic fields were studied. An apparent substorm (including thinning of the dayside tail current sheet) was observed at Jupiter, as well as evidence suggesting that at the magnetopause the cusp is at an abnormally low latitude. The characteristics of Saturn's ring current as observed by Pioneer 11 were dramatically different from those suggested by the Voyager observations. Most importantly, very strong perturbations in the azimuthal ring current magnetic field suggest that the plane of the ring was not in the dipole equatorial plane, being tilted 5 to 10 deg. relative to the dipole and undergoing significant changes during the encounter. When these changing currents were corrected for, an improved planetary field determination was obtained. In addition, the ring and azimuthal currents at Saturn displayed significantly different time dependences.
Pan, Feng; Liu, Shuo; Wang, Zhe; Shang, Peng; Xiao, Wen
2012-05-07
The long-term and real-time monitoring the cell division and changes of osteoblasts under simulated zero gravity condition were succeed by combing a digital holographic microscopy (DHM) with a superconducting magnet (SM). The SM could generate different magnetic force fields in a cylindrical cavity, where the gravitational force of biological samples could be canceled at a special gravity position by a high magnetic force. Therefore the specimens were levitated and in a simulated zero gravity environment. The DHM was modified to fit with SM by using single mode optical fibers and a vertically-configured jig designed to hold specimens and integrate optical device in the magnet's bore. The results presented the first-phase images of living cells undergoing dynamic divisions and changes under simulated zero gravity environment for a period of 10 hours. The experiments demonstrated that the SM-compatible DHM setup could provide a highly efficient and versatile method for research on the effects of microgravity on biological samples.
Phase Coexistence and Kinetic Arrest in the Magnetostructural Transition of the Ordered Alloy FeRh
Keavney, David J.; Choi, Yongseong; Holt, Martin V.; ...
2018-01-29
In materials where two or more ordering degrees of freedom are closely matched in their free energies, coupling between them, or multiferroic behavior can occur. These phenomena can produce a very rich phase behavior, as well as emergent phases that offer useful properties and opportunities to reveal novel phenomena in phase transitions. The ordered alloy FeRh undergoes an antiferromagnetic to ferromagnetic phase transition at ~375 K, which illustrates the interplay between structural and magnetic order mediated by a delicate energy balance between two configurations. We have examined this transition using a combination of high-resolution x-ray structural and magnetic imaging andmore » comprehensive x-ray magnetic circular dichroism spectroscopy. We find that the transition proceeds via a defect-driven domain nucleation and growth mechanism, with significant return point memory in both the structural and magnetic domain configurations. In conclusion, the domains show evidence of inhibited growth after nucleation, resulting in a quasi- 2nd order temperature behavior.« less
Rana, S; Gallo, A; Srivastava, R S; Misra, R D K
2007-03-01
Superparamagnetic nickel ferrite nanoparticles functionalized with polyvinyl alcohol, polyethylene oxide and polymethacrylic acid (PMAA) polymers and subsequently conjugated with doxorubicin anti-cancer drug are studied for their use as a magnetic carrier for drug delivery. Fourier transform infrared spectroscopy enabled examination of the ability of the nanoparticles to be functionalized with polymers and conjugated with doxorubicin drug. The functionalized polymer-coated nanocrystalline nickel ferrites retain the magnetic characteristics of non-functionalized nanocrystalline nickel ferrites (superparamagnetism, absence of hysteresis, remanence and coercivity at room temperature), encouraging their application as a magnetic carrier for drug delivery. The PMAA-coated nanoferrites are demonstrated as being a potentially superior magnetically targeted drug carrier based on FTIR results and drug release kinetics in the absence and presence of an external magnetic field.
Schroeter, Aileen; Grandjean, Joanes; Schlegel, Felix; Saab, Bechara J; Rudin, Markus
2017-07-01
Previously, we reported widespread bilateral increases in stimulus-evoked functional magnetic resonance imaging signals in mouse brain to unilateral sensory paw stimulation. We attributed the pattern to arousal-related cardiovascular changes overruling cerebral autoregulation thereby masking specific signal changes elicited by local neuronal activity. To rule out the possibility that interhemispheric neuronal communication might contribute to bilateral functional magnetic resonance imaging responses, we compared stimulus-evoked functional magnetic resonance imaging responses to unilateral hindpaw stimulation in acallosal I/LnJ, C57BL/6, and BALB/c mice. We found bilateral blood-oxygenation-level dependent signal changes in all three strains, ruling out a dominant contribution of transcallosal communication as reason for bilaterality. Analysis of functional connectivity derived from resting-state functional magnetic resonance imaging, revealed that bilateral cortical functional connectivity is largely abolished in I/LnJ animals. Cortical functional connectivity in all strains correlated with structural connectivity in corpus callosum as revealed by diffusion tensor imaging. Given the profound influence of systemic hemodynamics on stimulus-evoked functional magnetic resonance imaging outcomes, we evaluated whether functional connectivity data might be affected by cerebrovascular parameters, i.e. baseline cerebral blood volume, vascular reactivity, and reserve. We found that effects of cerebral hemodynamics on functional connectivity are largely outweighed by dominating contributions of structural connectivity. In contrast, contributions of transcallosal interhemispheric communication to the occurrence of ipsilateral functional magnetic resonance imaging response of equal amplitude to unilateral stimuli seem negligible.
Bio inspired Magnet-polymer (Magpol) actuators
NASA Astrophysics Data System (ADS)
Ahmed, Anansa S.; Ramanujan, R. V.
2014-03-01
Magnet filler-polymer matrix composites (Magpol) are an emerging class of morphing materials. Magpol composites have an interesting ability to undergo large strains in response to an external magnetic field. The potential to develop Magpol as large strain actuators is due to the ability to incorporate large particle loading into the composite and also due to the increased interaction area at the interface of the nanoparticles and the composite. Mn-Zn ferrite fillers with different saturation magnetizations (Ms) were synthesized. Magpol composites consisting of magnetic ferrite filler particles in an Poly ethylene vinyl acetate (EVA) matrix were prepared. The deformation characteristics of the actuator were determined. The morphing ability of the Magpol composite was studied under different magnetic fields and also with different filler loadings. All films exhibited large strain under the applied magnetic field. The maximum strain of the composite showed an exponential dependence on the Ms. The work output of Magpol was also calculated using the work loop method. Work densities of upto 1 kJ/m3 were obtained which can be compared to polypyrrole actuators, but with almost double the typical strain. Applications of Magpol can include artificial muscles, drug delivery, adaptive optics and self healing structures. Advantages of Magpol include remote contactless actuation, high actuation strain and strain rate and quick response.
NASA Astrophysics Data System (ADS)
Lei, Shiming; Chikara, Shalinee; Puggioni, Danilo; Ke, Xianglin; Mao, Z. Q.; Rondinelli, J. M.; Jaime, Marcelo; Singleton, John; Zapf, Vivien; Gopalan, Venkatraman
Ca3Ru2O7 undergoes a second-order magnetic phase transition to AFM-a (ferromagnetic bilayers antiferromagnetically stack along c-axis with magnetic easy axis along a) at TN = 56 K, followed by a concomitant first-order structural and magnetic phase transition to an AFM-b (antiferromagnetic with magnetic easy axis along b) at TS = 48 K. For T<30 K, a quasi-two-dimensional (2D) metallic state exists due to the survival of small non-nested Fermi pockets. With a proper magnetic field applied along b-axis, an additional phase of canted-AFM is induced. Here we propose a new strategy to tune the polar metal Ca3Ru2O7 into insulating state by chemical doping. In the meantime, the superexchange interaction is significantly weakened to allow the existence of a weak ferromagnetic state. Combined with its robust polar nature, we offer an experimental demonstration of a new multiferroic material. The mechanism is further discussed in the framework of hybrid improper ferroelectricity proposed by Benedek and Fennie. This new strategy proposed here may be utilized as a general approach for new multiferroics starting from a material on the verge of the Mott insulating. Here we will discuss our comprehensive magnetization and magnetostriction, and magnetic field dependent SHG study on this material
The Mechanism for the Energy Buildup Driving Solar Eruptive Events
NASA Astrophysics Data System (ADS)
Knizhnik, K. J.; Antiochos, S. K.; DeVore, C. R.; Wyper, P. F.
2017-12-01
The underlying origin of solar eruptive events (SEEs), ranging from giant coronal mass ejections to small coronal-hole jets, is that the lowest-lying magnetic flux in the Sun’s corona undergoes continual buildup of stress and free energy. This magnetic stress has long been observed as the phenomenon of “filament channels:” strongly sheared magnetic field localized around photospheric polarity inversion lines. However, the mechanism for the stress buildup—the formation of filament channels—is still debated. We present magnetohydrodynamic simulations of a coronal volume that is driven by transient, cellular boundary flows designed to model the processes by which the photosphere drives the corona. The key feature of our simulations is that they accurately preserve magnetic helicity, the topological quantity that is conserved even in the presence of ubiquitous magnetic reconnection. Although small-scale random stress is injected everywhere at the photosphere, driving stochastic reconnection throughout the corona, the net result of the magnetic evolution is a coherent shearing of the lowest-lying field lines. This highly counterintuitive result—magnetic stress builds up locally rather than spreading out to attain a minimum energy state—explains the formation of filament channels and is the fundamental mechanism underlying SEEs. Furthermore, this process is likely to be relevant to other astrophysical and laboratory plasmas.
First-order ferromagnetic to helimagnetic transition in MgMn6Ge6
NASA Astrophysics Data System (ADS)
Mazet, T.; Ihou-Mouko, H.; Malaman, B.
2008-02-01
The magnetic and magnetocaloric properties of the new HfFe6Ge6-type (P6/mmm) MgMn6Ge6 compound have been studied by magnetic measurements and powder neutron diffraction experiments. MgMn6Ge6 magnetically orders at TC˜345 K in a ferromagnetic easy-plane arrangement. At TAF˜235 K, it undergoes a first-order transition to a helical structure, characterized by a temperature dependent propagation vector k =⟨0,0,qz⟩ (qz˜0.116 reciprocal lattice units at 1.4 K), without structural modification. The Mn atoms carry a magnetic moment of about 2 μB. A metamagnetic transition with a low critical field (Hcr<1 T) is observed below TAF. At low temperature, both magnetic and magnetocaloric data strongly suggest that some kinds of intermediate noncollinear ferromagnetic arrangements are stabilized above the critical field while the pure ferromagnetic state is obtained for significantly higher magnetic fields (H >5 T). The magnitude of the magnetic entropy change at TC (-ΔSM˜20.5 mJ cm-3 K-1 for ΔH =5 T) is about 25% that of Gd metal. The magnetocaloric effect at the order-order transition is of opposite sign and of lower magnitude.
Sedation protocol with fasting and shorter sleep leads to magnetic resonance imaging success.
Kimiya, Takahisa; Sekiguchi, Shinichiro; Yagihashi, Tatsuhiko; Arai, Mie; Takahashi, Hirotaka; Takahashi, Takao
2017-10-01
Young children undergoing magnetic resonance imaging (MRI) require sedation. In June 2013, Tokyo Metropolitan Ohtsuka Hospital (TMOH) introduced an oral sedation protocol for young children undergoing MRI; the protocol included instructions on fasting before sedation, and recommended a shorter duration of sleep the night before MRI. We compared the MRI success rate before and after the introduction of this protocol. The eligible subjects were children under 3 years old who underwent MRI by appointment at TMOH between October 2012 and March 2014, under sedation with triclofos sodium. All those who underwent MRI in or after June 2013 were enrolled prospectively as a post-protocol group. All patients who underwent MRI before June 2013 were enrolled retrospectively as a pre-protocol group, with data collected from chart review. Seventy-four patients were enrolled in the post-protocol group, and 42 in the pre-protocol group. The MRI success rate was significantly higher in the post-protocol group than in the pre-protocol group (98.7% vs 88.1%), as was the rate of on-time starting of MRI (86.5% vs 71.4%). The post-protocol group woke up earlier on the day of examination (6:18 a.m. vs 6:43 a.m.), resulting in a significantly longer time between awakening and the beginning of sedation (289.8 min vs 265.9 min), and a significantly shorter average duration of sleep on the previous night (504.8 min vs 532.3 min). Implementation of a hospital-wide sedation protocol for young children undergoing MRI significantly improved the MRI success rate. © 2017 Japan Pediatric Society.
Safety of magnetic resonance imaging of stapes prostheses.
Syms, Mark James
2005-03-01
Assess the safety of performing magnetic resonance imaging (MRI) on patients with stapes prostheses. Survey and animal model. A survey regarding implant usage, MRI procedures, and adverse outcomes after MRI in patients previously undergoing stapes procedures. Guinea pigs implanted with ferromagnetic 17 to 4 stainless steel, 316L nonferromagnetic stainless steel, titanium, and fluoroplastic stapes prostheses underwent a MRI in a 4.7 Tesla MR system. : Three adverse outcomes were reported on the clinical survey. One adverse event occurred during an MRI performed on a recalled ferromagnetic prosthesis. The other two adverse events were probably not secondary to MRI exposure. No damage or inflammation was observed in the region of the oval window or vestibule of implanted guinea pigs exposed to a 4.7 Tesla MR system. The combination of prior studies, the clinical survey, and the absence of histopathologic evidence of damage in the guinea pigs is compelling evidence that MRI for patients with stapes prostheses is safe. Implanting physicians should feel comfortable clearing a patient for a MRI in a 1.5 Tesla or 3.0 Tesla MRI. It is imperative for the physician to qualify the field strength when clearing a patient to undergo a MRI.
Building Magnetic Fields in White Dwarfs
NASA Astrophysics Data System (ADS)
Kohler, Susanna
2017-03-01
White dwarfs, the compact remnants left over at the end of low- and medium-mass stars lifetimes, are often found to have magnetic fields with strengths ranging from thousands to billions of times that of Earth. But how do these fields form?MultiplePossibilitiesAround 1020% of white dwarfs have been observed to have measurable magnetic fields with a wide range of strengths. There are several theories as to how these fields might be generated:The fields are fossil.The original weak magnetic fields of the progenitor stars were amplified as the stars cores evolved into white dwarfs.The fields are caused by binary interactions.White dwarfs that formed in the merger of a binary pair might have had a magnetic field amplified as a result of a dynamo that was generated during the merger.The fields were produced by some other internal physical mechanism during the cooling of the white dwarf itself.In a recent publication, a team of authors led by Jordi Isern (Institute of Space Sciences, CSIC, and Institute for Space Studies of Catalonia, Spain) explored this third possibility.Dynamos from CrystallizationThe inner and outer boundaries of the convective mantle of carbon/oxygen white dwarfs of two different masses (top vs. bottom panel) as a function of luminosity. As the white dwarf cools (toward the right), the mantle grows thinner due to the crystallization and settling of material. [Isern et al. 2017]As white dwarfs have no nuclear fusion at their centers, they simply radiate heat and gradually cool over time. The structure of the white dwarf undergoes an interesting change as it cools, however: though the object begins as a fluid composed primarily of an ionized mixture of carbon and oxygen (and a few minor species like nickel and iron), it gradually crystallizes as its temperature drops.The crystallized phase of the white dwarf is oxygen-rich which is denser than the liquid, so the crystallized material sinks to the center of the dwarf as it solidifies. As a result, the white dwarf forms a solid, oxygen-rich core with a liquid, carbon-rich mantle thats Rayleigh-Taylor unstable: as crystallization continues, the solids continue to sink out of the mantle.By analytically modeling this process, Isern and collaborators demonstrate that the Rayleigh-Taylor instabilities in the convective mantle can drive a dynamo large enough to generate the magnetic field strengths weve observed in white dwarfs.Magnetic field density as a function of the dynamo energy density. The plots show Earth and Jupiter (black dots), T Tauri stars (cyan), M dwarf stars (magenta), and two types of white dwarfs (blue and red). Do these lie on the same scaling relation? [Isern et al. 2017]A Universal Process?This setup the solid core with an unstable liquid mantle on top is exactly the structure expected to occur in planets such as Earth and Jupiter. These planets magnetic fields are similarly thought to be generated by convective dynamos powered by the cooling and chemical separation of their interiors and the process can also be scaled up to account for the magnetic fields of fully convective objects like T Tauri stars, as well.If white-dwarf magnetic fields are generated by the same type of dynamo, this may be a universal process for creating magnetic fields in astrophysical objects though other processes may well be at work too.CitationJordi Isern et al 2017 ApJL 836 L28. doi:10.3847/2041-8213/aa5eae
Limotai, Chusak; McLachlan, Richard S; Hayman-Abello, Susan; Hayman-Abello, Brent; Brown, Suzan; Bihari, Frank; Mirsattari, Seyed M
2018-06-19
This study was aimed to longitudinally assess memory function and whole-brain memory circuit reorganization in patients with temporal lobe epilepsy (TLE) by comparing activation potentials before versus after anterior temporal lobe (ATL) resection. Nineteen patients with medically-intractable TLE (10 left TLE, 9 right TLE) and 15 healthy controls were enrolled. Group analyses were conducted pre- and post-ATL of a novelty complex scene-encoding paradigm comparing areas of blood oxygen-level-dependent (BOLD) signal activations on functional magnetic resonance imaging (fMRI). None of the pre-operative patient characteristics we studied predicted the extent of pre- to post-operative memory loss. On fMRI, extra-temporal activations were detected pre-operatively in both LTLE and RTLE, particularly in the frontal lobe. Greater activations also were noted in the contralateral hippocampus and parahippocampus in both groups. Performing within-subject comparisons, post-op relative to pre-op, pronounced ipsilateral activations were identified in the left parahippocampal gyrus in LTLE, versus the right middle temporal gyrus in RTLE patients. Memory function was impaired pre-operatively but declined after ATL resection in both RTLE and LTLE patients. Post-operative fMRI results indicate possible functional adaptations to ATL loss, primarily occurring within the left parahippocampal gyrus versus right middle temporal gyrus in LTLE versus RTLE patients, respectively. Copyright © 2018 Elsevier Ltd. All rights reserved.
Functional organization of the language network in three- and six-year-old children.
Vissiennon, Kodjo; Friederici, Angela D; Brauer, Jens; Wu, Chiao-Yi
2017-04-01
The organization of the language network undergoes continuous changes during development as children learn to understand sentences. In the present study, functional magnetic resonance imaging and behavioral measures were utilized to investigate functional activation and functional connectivity (FC) in three-year-old (3yo) and six-year-old (6yo) children during sentence comprehension. Transitive German sentences varying the word order (subject-initial and object-initial) with case marking were presented auditorily. We selected children who were capable of processing the subject-initial sentences above chance level accuracy from each age group to ensure that we were tapping real comprehension. Both age groups showed a main effect of word order in the left posterior superior temporal gyrus (pSTG), with greater activation for object-initial compared to subject-initial sentences. However, age differences were observed in the FC between left pSTG and the left inferior frontal gyrus (IFG). The 6yo group showed stronger FC between the left pSTG and Brodmann area (BA) 44 of the left IFG compared to the 3yo group. For the 3yo group, in turn, the FC between left pSTG and left BA 45 was stronger than with left BA 44. Our study demonstrates that while task-related activation was comparable, the small behavioral differences between age groups were reflected in the underlying functional organization revealing the ongoing development of the neural language network. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
NASA Astrophysics Data System (ADS)
Arima, Taka-Hisa
2014-03-01
Pyrochlore-type 5d transition-metal oxide compounds Cd2Os2O7 and R2Ir2O7 (R =rare earth) undergo a metal-insulator transition accompanied by a magnetic transition. Recently, the magnetic structures of Cd2Os2O7 and Eu2Ir2O7 were investigated by means of resonant x-ray magnetic scattering. The x-ray data indicated the all-in/all-out type magnetic order. The all-in/all-out order breaks the time-reversal symmetry, while the spontaneous magnetization is essentially absent. The magnetic order can be viewed as ferroic magnetic octupolar order. The magnetic order is expected to provide several unique physical properties like quadratic magnetization. linear magneto-capacitance, linear magneto-resistance, linear magneto-mechanical coupling and so on. The symmetry breaking results in two non-equivalent domains, ``all-in/all-out'' and ``all-out/all-in.'' Interestingly, some theoretical works predict that a peculiar metallic state would appear on the domain wall. The observation and control of the domain distribution are essential for studying verious exotic physical responses. We have developed an x-ray technique for domain imaging and started studying the effects of external stimuli on the domain distribution. This work was performed in collaboration with S. Tardif, S. Takeshita, H. Ohsumi, D. Uematsu, H. Sagayama, J. J. Ishikawa, S. Nakatsuji, J. Yamaura, and Z. Hiroi.
Santos, Paulo Roberto; Capote, José Roberto Frota Gomes; Cavalcanti, Juliana Uchoa; Vieira, Cyntia Brito; Rocha, Ana Rochelle Mesquita; Apolônio, Natália Alves Mineiro; de Oliveira, Elaine Barbosa
2012-08-31
Sexual function among women undergoing hemodialysis (HD) is under-studied and there is no consensus about the effect of sexual dysfunction (SD) on their quality of life (QoL). We aimed to determine the prevalence of SD and to compare QoL between women undergoing maintenance HD with and without SD. We included female end-stage renal disease (ESRD) patients undergoing HD during June 2011 in the only renal unit in the north of Ceará state, northeastern Brazil. The criteria for inclusion were age between 18 and 55, at least three months on dialysis and being sexually active. Women using antidepressant medication were excluded. We used the Female Sexual Function Index (FSFI), which evaluates six domains of sexual function, including desire, arousal, lubrication, orgasm, satisfaction and pain. The patients were classified as presenting SD if the total FSFI score was less than 26. For QoL evaluation, we used the validated Brazilian version of SF-36. This is a widely used 36-item questionnaire covering eight dimensions of QoL. Demographic data, time on dialysis, underlying etiology of ESRD, and laboratory measures were assessed in unit records. Of a total of 58 women, 46 (79.3%) presented SD. There were lower scores related to physical functioning (48.2 vs. 71.2; p = 0.007), bodily pain (45 vs. 67.5; p = 0.010), vitality (52.1 vs. 69.1; p = 0.026) and social functioning (57.2 vs. 76.1; p = 0.034) among women with SD compared to women without SD. Physical functioning and role-physical presented positive linear correlation with FSFI scores, respectively, r = 0.322 (p = 0.013) and r = 0.345 (p = 0.007). The prevalence of SD among women on HD is very high, reaching nearly 80%. Women on HD with SD had worse QoL, especially physical aspects of QoL, when compared to women without SD. Therefore, approaches aiming to improve QoL among women undergoing HD should be considered.
Quantum Mechanics in Insulators
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aeppli, G.; Department of Physics and Astronomy, University College of London, London
Atomic physics is undergoing a large revival because of the possibility of trapping and cooling ions and atoms both for individual quantum control as well as collective quantum states, such as Bose-Einstein condensates. The present lectures start from the 'atomic' physics of isolated atoms in semiconductors and insulators and proceed to coupling them together to yield magnets undergoing quantum phase transitions as well as displaying novel quantum states with no classical analogs. The lectures are based on: G.-Y. Xu et al., Science 317, 1049-1052 (2007); G. Aeppli, P. Warburton, C. Renner, BT Technology Journal, 24, 163-169 (2006); H. M. Ronnowmore » et al., Science 308, 392-395 (2005) and N. Q. Vinh et al., PNAS 105, 10649-10653 (2008).« less
Rapid cycling medical synchrotron and beam delivery system
Peggs, Stephen G [Port Jefferson, NY; Brennan, J Michael [East Northport, NY; Tuozzolo, Joseph E [Sayville, NY; Zaltsman, Alexander [Commack, NY
2008-10-07
A medical synchrotron which cycles rapidly in order to accelerate particles for delivery in a beam therapy system. The synchrotron generally includes a radiofrequency (RF) cavity for accelerating the particles as a beam and a plurality of combined function magnets arranged in a ring. Each of the combined function magnets performs two functions. The first function of the combined function magnet is to bend the particle beam along an orbital path around the ring. The second function of the combined function magnet is to focus or defocus the particle beam as it travels around the path. The radiofrequency (RF) cavity is a ferrite loaded cavity adapted for high speed frequency swings for rapid cycling acceleration of the particles.
Mullen, Anna; Hall, Jenny; Diegel, Janika; Hassan, Isa; Fey, Adam; MacMillan, Fraser
2016-06-15
During their mechanistic cycles membrane transporters often undergo extensive conformational changes, sampling a range of orientations, in order to complete their function. Such membrane transporters present somewhat of a challenge to conventional structural studies; indeed, crystallization of membrane-associated proteins sometimes require conditions that vary vastly from their native environments. Moreover, this technique currently only allows for visualization of single selected conformations during any one experiment. EPR spectroscopy is a magnetic resonance technique that offers a unique opportunity to study structural, environmental and dynamic properties of such proteins in their native membrane environments, as well as readily sampling their substrate-binding-induced dynamic conformational changes especially through complementary computational analyses. Here we present a review of recent studies that utilize a variety of EPR techniques in order to investigate both the structure and dynamics of a range of membrane transporters and associated proteins, focusing on both primary (ABC-type transporters) and secondary active transporters which were key interest areas of the late Professor Stephen Baldwin to whom this review is dedicated. © 2016 The Author(s). Published by Portland Press Limited on behalf of the Biochemical Society.
Takiguchi, Shinichiro; Fujisawa, Takashi X.; Mizushima, Sakae; Saito, Daisuke N.; Okamoto, Yuko; Shimada, Koji; Koizumi, Michiko; Kumazaki, Hirokazu; Jung, Minyoung; Kosaka, Hirotaka; Hiratani, Michio; Ohshima, Yusei; Teicher, Martin H.
2015-01-01
Background Child maltreatment is a major risk factor for psychopathology, including reactive attachment disorder (RAD). Aims To examine whether neural activity during reward processing was altered in children and adolescents with RAD. Method Sixteen children and adolescents with RAD and 20 typically developing (TD) individuals performed tasks with high and low monetary rewards while undergoing functional magnetic resonance imaging. Results Significantly reduced activity in the caudate and nucleus accumbens was observed during the high monetary reward condition in the RAD group compared with the TD group (P=0.015, family-wise error-corrected cluster level). Significant negative correlations between bilateral striatal activity and avoidant attachment were observed in the RAD and TD groups. Conclusions Striatal neural reward activity in the RAD group was markedly decreased. The present results suggest that dopaminergic dysfunction occurs in the striatum of children and adolescents with RAD, leading towards potential future risks for psychopathology. Declaration of interest None. Copyright and usage © The Royal College of Psychiatrists 2015. This is an open access article distributed under the terms of the Creative Commons Non-Commercial, No Derivatives (CC BY-NC-ND) licence. PMID:27703736
Hydroxychloroquine-induced cardiomyopathy: case report, pathophysiology, diagnosis, and treatment.
Yogasundaram, Haran; Putko, Brendan N; Tien, Julia; Paterson, D Ian; Cujec, Bibiana; Ringrose, Jennifer; Oudit, Gavin Y
2014-12-01
Drug-induced heart and vascular disease remains an important health burden. Hydroxychloroquine and its predecessor chloroquine are medications commonly used in the treatment of systemic lupus erythematosus, rheumatoid arthritis, and other connective tissue disorders. Hydroxychloroquine interferes with malarial metabolites, confers immunomodulatory effects, and also affects lysosomal function. Clinical monitoring and early recognition of toxicity is an important management strategy in patients who undergo long-term treatment with hydroxychloroquine. Retinal toxicity, neuromyopathy, and cardiac disease are recognized adverse effects of hydroxychloroquine. Immediate withdrawal of hydroxychloroquine is essential if toxicity is suspected because of the early reversibility of cardiomyopathy. In addition to recommended ophthalmological screening, regular screening with 12-lead electrocardiogram and transthoracic echocardiography to detect conduction system disease and/or biventricular morphological or functional changes should be considered in hydroxychloroquine-treated patients. Cardiac magnetic resonance imaging and endomyocardial biopsy are valuable tools to provide prognostic insights and confirm the diagnosis of hydroxychloroquine-induced cardiomyopathy. In conclusion, chronic use of hydroxychloroquine can result in an acquired lysosomal storage disorder, leading to a drug-induced cardiomyopathy characterized by concentric hypertrophy and conduction abnormalities associated with increased adverse clinical outcomes and mortality. Copyright © 2014 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.
Dynamic mechanical oscillations during metamorphosis of the monarch butterfly
Pelling, Andrew E; Wilkinson, Paul R; Stringer, Richard; Gimzewski, James K
2008-01-01
The mechanical oscillation of the heart is fundamental during insect metamorphosis, but it is unclear how morphological changes affect its mechanical dynamics. Here, the micromechanical heartbeat with the monarch chrysalis (Danaus plexippus) during metamorphosis is compared with the structural changes observed through in vivo magnetic resonance imaging (MRI). We employ a novel ultra-sensitive detection approach, optical beam deflection, in order to measure the microscale motions of the pupae during the course of metamorphosis. We observed very distinct mechanical contractions occurring at regular intervals, which we ascribe to the mechanical function of the heart organ. Motion was observed to occur in approximately 15 min bursts of activity with frequencies in the 0.4–1.0 Hz range separated by periods of quiescence during the first 83 per cent of development. In the final stages, the beating was found to be uninterrupted until the adult monarch butterfly emerged. Distinct stages of development were characterized by changes in frequency, amplitude, mechanical quality factor and de/repolarization times of the mechanical pulsing. The MRI revealed that the heart organ remains functionally intact throughout metamorphosis but undergoes morphological changes that are reflected in the mechanical oscillation. PMID:18682363
Hayes, Jasmeet Pannu; LaBar, Kevin S.; Petty, Christopher M.; McCarthy, Gregory; Morey, Rajendra A.
2009-01-01
Information processing models of posttraumatic stress disorder (PTSD) suggest that PTSD is characterized by preferential allocation of attentional resources to potentially threatening stimuli. However, few studies have examined the neural pattern underlying attention and emotion in association with PTSD symptomatology. In the present study, combat veterans with PTSD symptomatology engaged in an emotional oddball task while undergoing functional magnetic resonance imaging (fMRI). Veterans were classified into a high or low symptomatology group based on their scores on the Davidson Trauma Scale (DTS). Participants discriminated infrequent target stimuli (circles) from frequent standards (squares) while emotional and neutral distractors were presented infrequently and irregularly. Results revealed that participants with greater PTSD symptomatology showed enhanced neural activity in ventral-limbic and dorsal regions for emotional stimuli and attenuated activity in dorsolateral prefrontal and parietal regions for attention targets. In the anterior cingulate gyrus, participants with fewer PTSD symptoms showed equivalent responses to attentional and emotional stimuli while the high symptom group showed greater activation for negative emotional stimuli. Taken together, the results suggest that hyperresponsive ventral-limbic activity coupled with altered dorsal-attention and anterior cingulate function may be a neural marker of attention bias in PTSD. PMID:19237269
Neural correlates of the object-recall process in semantic memory.
Assaf, Michal; Calhoun, Vince D; Kuzu, Cheedem H; Kraut, Michael A; Rivkin, Paul R; Hart, John; Pearlson, Godfrey D
2006-10-30
The recall of an object from features is a specific operation in semantic memory in which the thalamus and pre-supplementary motor area (pre-SMA) are integrally involved. Other higher-order semantic cortices are also likely to be involved. We used the object-recall-from-features paradigm, with more sensitive scanning techniques and larger sample size, to replicate and extend our previous results. Eighteen right-handed healthy participants performed an object-recall task and an association semantic task, while undergoing functional magnetic resonance imaging. During object-recall, subjects determined whether words pairs describing object features combined to recall an object; during the association task they decided if two words were related. Of brain areas specifically involved in object recall, in addition to the thalamus and pre-SMA, other regions included the left dorsolateral prefrontal cortex, inferior parietal lobule, and middle temporal gyrus, and bilateral rostral anterior cingulate and inferior frontal gyri. These regions are involved in semantic processing, verbal working memory and response-conflict detection and monitoring. The thalamus likely helps to coordinate activity of these different brain areas. Understanding the circuit that normally mediates this process is relevant for schizophrenia, where many regions in this circuit are functionally abnormal and semantic memory is impaired.
Supraspinal Control of Urine Storage and Micturition in Men—An fMRI Study
Michels, Lars; Blok, Bertil F.M.; Gregorini, Flavia; Kurz, Michael; Schurch, Brigitte; Kessler, Thomas M.; Kollias, Spyros; Mehnert, Ulrich
2015-01-01
Despite the crucial role of the brain in the control of the human lower urinary tract, little is known about the supraspinal mechanisms regulating micturition. To investigate the central regulatory mechanisms activated during micturition initiation and actual micturition, we used an alternating sequence of micturition imitation/imagination, micturition initiation, and actual micturition in 22 healthy males undergoing functional magnetic resonance imaging. Subjects able to micturate (voiders) showed the most prominent supraspinal activity during the final phase of micturition initiation whereas actual micturition was associated with significantly less such activity. Initiation of micturition in voiders induced significant activity in the brainstem (periaqueductal gray, pons), insula, thalamus, prefrontal cortex, parietal operculum and cingulate cortex with significant functional connectivity between the forebrain and parietal operculum. Subjects unable to micturate (nonvoiders) showed less robust activation during initiation of micturition, with activity in the forebrain and brainstem particularly lacking. Our findings suggest that micturition is controlled by a specific supraspinal network which is essential for the voluntary initiation of micturition. Once this network triggers the bulbospinal micturition reflex via brainstem centers, micturition continues automatically without further supraspinal input. Unsuccessful micturition is characterized by a failure to activate the periaqueductal gray and pons during initiation. PMID:24969474
Adaptive Plasticity in the Healthy Language Network: Implications for Language Recovery after Stroke
2016-01-01
Across the last three decades, the application of noninvasive brain stimulation (NIBS) has substantially increased the current knowledge of the brain's potential to undergo rapid short-term reorganization on the systems level. A large number of studies applied transcranial magnetic stimulation (TMS) and transcranial direct current stimulation (tDCS) in the healthy brain to probe the functional relevance and interaction of specific areas for different cognitive processes. NIBS is also increasingly being used to induce adaptive plasticity in motor and cognitive networks and shape cognitive functions. Recently, NIBS has been combined with electrophysiological techniques to modulate neural oscillations of specific cortical networks. In this review, we will discuss recent advances in the use of NIBS to modulate neural activity and effective connectivity in the healthy language network, with a special focus on the combination of NIBS and neuroimaging or electrophysiological approaches. Moreover, we outline how these results can be transferred to the lesioned brain to unravel the dynamics of reorganization processes in poststroke aphasia. We conclude with a critical discussion on the potential of NIBS to facilitate language recovery after stroke and propose a phase-specific model for the application of NIBS in language rehabilitation. PMID:27830094
Itsukage, Shizu; Sowa, Yoshihiro; Goto, Mariko; Taguchi, Tetsuya; Numajiri, Toshiaki
2017-01-01
Objective: Preoperative prediction of breast volume is important in the planning of breast reconstructive surgery. In this study, we prospectively estimated the accuracy of measurement of breast volume using data from 2 routine modalities, mammography and magnetic resonance imaging, by comparison with volumes of mastectomy specimens. Methods: The subjects were 22 patients (24 breasts) who were scheduled to undergo total mastectomy for breast cancer. Preoperatively, magnetic resonance imaging volume measurement was performed using a medical imaging system and the mammographic volume was calculated using a previously proposed formula. Volumes of mastectomy specimens were measured intraoperatively using a method based on Archimedes' principle and Newton's third law. Results: The average breast volumes measured on magnetic resonance imaging and mammography were 318.47 ± 199.4 mL and 325.26 ± 217.36 mL, respectively. The correlation coefficients with mastectomy specimen volumes were 0.982 for magnetic resonance imaging and 0.911 for mammography. Conclusions: Breast volume measurement using magnetic resonance imaging was highly accurate but requires data analysis software. In contrast, breast volume measurement with mammography requires only a simple formula and is sufficiently accurate, although the accuracy was lower than that obtained with magnetic resonance imaging. These results indicate that mammography could be an alternative modality for breast volume measurement as a substitute for magnetic resonance imaging.
Itsukage, Shizu; Goto, Mariko; Taguchi, Tetsuya; Numajiri, Toshiaki
2017-01-01
Objective: Preoperative prediction of breast volume is important in the planning of breast reconstructive surgery. In this study, we prospectively estimated the accuracy of measurement of breast volume using data from 2 routine modalities, mammography and magnetic resonance imaging, by comparison with volumes of mastectomy specimens. Methods: The subjects were 22 patients (24 breasts) who were scheduled to undergo total mastectomy for breast cancer. Preoperatively, magnetic resonance imaging volume measurement was performed using a medical imaging system and the mammographic volume was calculated using a previously proposed formula. Volumes of mastectomy specimens were measured intraoperatively using a method based on Archimedes’ principle and Newton's third law. Results: The average breast volumes measured on magnetic resonance imaging and mammography were 318.47 ± 199.4 mL and 325.26 ± 217.36 mL, respectively. The correlation coefficients with mastectomy specimen volumes were 0.982 for magnetic resonance imaging and 0.911 for mammography. Conclusions: Breast volume measurement using magnetic resonance imaging was highly accurate but requires data analysis software. In contrast, breast volume measurement with mammography requires only a simple formula and is sufficiently accurate, although the accuracy was lower than that obtained with magnetic resonance imaging. These results indicate that mammography could be an alternative modality for breast volume measurement as a substitute for magnetic resonance imaging. PMID:29308107
Castelvecchio, Serenella; Careri, Giulia; Ambrogi, Federico; Camporeale, Antonia; Menicanti, Lorenzo; Secchi, Francesco; Lombardi, Massimo
2018-01-01
Post-infarction myocardial scar causes adverse left ventricular remodelling and negatively affects the prognosis. We sought to investigate whether scar extent and location obtained by cardiac magnetic resonance may affect the reverse remodelling and survival of heart failure patients undergoing surgical ventricular reconstruction. From January 2011 to December 2015, 151 consecutive patients with previous myocardial infarction and left ventricular remodelling underwent surgical ventricular reconstruction at our Institution, of which 88 (58%) patients had a preoperative protocol-standardized late gadolinium enhancement (LGE)-cardiac magnetic resonance examination during the week before surgery. We excluded 40 patients with devices (26%), 15 patients with irregular heart rhythm (permanent atrial fibrillation, 10% not included in the device group) or mixed contraindications (severe claustrophobia or presence of material magnetic resonance not compatible). Among the 145 survivors, 11 patients received an implantable cardioverter defibrillator after surgery (mostly for persistent low ejection fraction) and were excluded as well, yielding a total of 59 patients (48 men, aged 65 ± 9 years) who repeated a protocol-standardized LGE-cardiac magnetic resonance examination even 6 months postoperatively and therefore represent the study population. Patients were grouped according to the presence of LGE in the antero-basal left ventricular segments (Group A) or the absence of LGE in the same segments (Group B). The postoperative left ventricular end-systolic volume index was considered the primary end-point. After surgery, left ventricular end-systolic volume index and end-diastolic volume index significantly decreased (P < 0.001, for both), while diastolic sphericity index and ejection fraction significantly increased (P = 0.015 and P < 0.001, respectively). The presence of LGE in the antero-basal left ventricular segments (10 patients, Group A) was the only independent predictor of outcome (P = 0.02) at multivariate analysis, being the postoperative left ventricular end-systolic volume index significantly higher compared to that of patients of Group B (49 patients) (78 ± 26 ml/m2 vs 55 ± 20 ml/m2, P = 0.003). Furthermore, patients with a postoperative left ventricular end-systolic volume index >60 ml/m2 showed a higher risk of cardiac events (hazard ratio = 3.67, P = 0.02). In patients undergoing surgical ventricular reconstruction, LGE scar location affects the left ventricular reverse remodelling, which in turn might limit the survival benefit. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Report from a quality assurance program on patients undergoing the MILD procedure.
Durkin, Brian; Romeiser, Jamie; Shroyer, A Laurie W; Schiller, Robin; Bae, Jin; Davis, Raphael P; Peyster, Robert; Benveniste, Helene
2013-05-01
To characterize trends in pain and functional outcomes and identify risk factors in patients with lumbar spinal stenosis (LSS) and neurogenic claudication undergoing the "Minimally Invasive Lumbar Decompression" (MILD) procedure. Retrospective observational cohort study. Academic multidisciplinary pain center at Stony Brook Medicine. Patients undergoing the MILD procedure from October 2010 to November 2012. De-identified perioperative, pain and function related data for 50 patients undergoing MILD were extracted from the Center for Pain Management's quality assessment database. Data included numerical rating scale (NRS), symptom severity and physical function (Zurich Claudication Questionnaire), functional status (Oswestry Disability Index [ODI]), pain interference scores (National Institutes of Health Patient-Reported Outcomes Measurement Information System [PROMIS]), and patients' self-reported low back and lower extremity pain distribution. No MILD patient incurred procedure-related complications. Average NRS scores decreased postoperatively and 64.3% of patients reported less pain at 3 months. Clinically meaningful functional ODI improvements of at least 20% from baseline were present in 25% of the patients at 6 months. Preliminary analysis of changes in PROMIS scores at 3 months revealed that pre-MILD "severe" lumbar canal stenosis may be associated with high risk of "no improvement." No such impact was observed for NRS or ODI outcomes. Overall, pain is reduced and functional status improved in LSS patients following the MILD procedure at 3 and 6 months. Given the small sample size, it is not yet possible to identify patient subgroups at risk for "no improvement." Continued follow-up of longer-term outcomes appears warranted to develop evidence-based patient selection criteria. Wiley Periodicals, Inc.
Functional Magnetic Resonance Imaging and Pediatric Anxiety
ERIC Educational Resources Information Center
Pine, Daniel S.; Guyer, Amanda E.; Leibenluft, Ellen; Peterson, Bradley S.; Gerber, Andrew
2008-01-01
The use of functional magnetic resonance imaging in investigating pediatric anxiety disorders is studied. Functional magnetic resonance imaging can be utilized in demonstrating parallels between the neural architecture of difference in anxiety of humans and the neural architecture of attention-orienting behavior in nonhuman primates or rodents.…
Smitha, K A; Akhil Raja, K; Arun, K M; Rajesh, P G; Thomas, Bejoy; Kapilamoorthy, T R; Kesavadas, Chandrasekharan
2017-08-01
The inquisitiveness about what happens in the brain has been there since the beginning of humankind. Functional magnetic resonance imaging is a prominent tool which helps in the non-invasive examination, localisation as well as lateralisation of brain functions such as language, memory, etc. In recent years, there is an apparent shift in the focus of neuroscience research to studies dealing with a brain at 'resting state'. Here the spotlight is on the intrinsic activity within the brain, in the absence of any sensory or cognitive stimulus. The analyses of functional brain connectivity in the state of rest have revealed different resting state networks, which depict specific functions and varied spatial topology. However, different statistical methods have been introduced to study resting state functional magnetic resonance imaging connectivity, yet producing consistent results. In this article, we introduce the concept of resting state functional magnetic resonance imaging in detail, then discuss three most widely used methods for analysis, describe a few of the resting state networks featuring the brain regions, associated cognitive functions and clinical applications of resting state functional magnetic resonance imaging. This review aims to highlight the utility and importance of studying resting state functional magnetic resonance imaging connectivity, underlining its complementary nature to the task-based functional magnetic resonance imaging.
A pacemaker magnet check alone is sufficient for the majority of patients postpacemaker implant.
Jones, Michael A; Wong, Kelvin C K; Qureshi, Norman; Rajappan, Kim; Bashir, Yaver; Betts, Timothy R
2014-12-01
Patients postpacemaker implant can undergo a full assessment by pacing system programmer (PSP) or a magnet check. The former takes longer, but provides more detailed information; a magnet-mode assessment is faster, but provides only capture data in an asynchronous pacing mode. A magnet-mode assessment alone may be sufficient in most cases, and current clinical practice varies considerably. A retrospective single-center assessment of all pacemaker implants receiving PSP and magnet checks between September 2009 and April 2010. Patient records were reviewed. The results of PSP and magnet checks and any subsequent device-related management were noted. A total of 168 patients underwent pacemaker implantation, magnet-mode assessment, and then PSP interrogation during this period. Magnet-mode assessment revealed a problem in only one patient-failure of atrial capture, leading to subsequent atrial lead repositioning. None of the remaining 167 patients have a serious problem at PSP interrogation; six had minor issues at PSP check, none of which required repeat surgical intervention. The magnet-mode test only provides information on lead capture in an asynchronous pacing mode, which is the most essential data postoperatively. Our study has suggested that a magnet-mode assessment without PSP interrogation may be sufficient in the immediate postimplant assessment of these patients. Routine postimplant PSP interrogation is time consuming, labor intensive, and adds only minimal additional benefit to the safe management of these patients above and beyond a magnet check, coupled with informed assessment of the associated electrocardiogram/rhythm strip, clinical examination, and chest x-ray. ©2014 Wiley Periodicals, Inc.
Two-fluid and finite Larmor radius effects on helicity evolution in a plasma pinch
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sauppe, J. P., E-mail: jpsauppe@gmail.com; Department of Physics, University of Wisconsin-Madison, 1150 University Avenue, Madison, Wisconsin 53706; Sovinec, C. R., E-mail: csovinec@wisc.edu
2016-03-15
The evolution of magnetic energy, helicity, and hybrid helicity during nonlinear relaxation of a driven-damped plasma pinch is compared in visco-resistive magnetohydrodynamics and two-fluid models with and without the ion gyroviscous stress tensor. Magnetic energy and helicity are supplied via a boundary electric field which initially balances the resistive dissipation, and the plasma undergoes multiple relaxation events during the nonlinear evolution. The magnetic helicity is well conserved relative to the magnetic energy over each event, which is short compared with the global resistive diffusion time. The magnetic energy decreases by roughly 1.5% of its initial value over a relaxation event,more » while the magnetic helicity changes by at most 0.2% of the initial value. The hybrid helicity is dominated by magnetic helicity in low-β pinch conditions and is also well conserved. Differences of less than 1% between magnetic helicity and hybrid helicity are observed with two-fluid modeling and result from cross helicity evolution. The cross helicity is found to change appreciably due to the first-order finite Larmor radius effects which have not been included in contemporary relaxation theories. The plasma current evolves towards the flat parallel current state predicted by Taylor relaxation theory but does not achieve it. Plasma flow develops significant structure for two-fluid models, and the flow perpendicular to the magnetic field is much more substantial than the flow along it.« less
Solomon, Marjorie; Yoon, Jong; Ragland, J. Daniel; Niendam, Tara; Lesh, Tyler A.; Fairbrother, Wonja; Carter, Cameron S.
2013-01-01
Background Autism spectrum disorders (ASD) involve impairments in cognitive control. In typical development (TYP), neural systems underlying cognitive control undergo substantial maturation during adolescence. Development is delayed in adolescents with ASD. Little is known about the neural substrates of this delay. Method We used event-related functional magnetic resonance imaging (fMRI) and a cognitive control task involving overcoming a prepotent response tendency to examine the development of cognitive control in young (ages 12–15; n = 13 with ASD and n = 13 with TYP) and older (ages 16–18; n= 14 with ASD and n = 14 with TYP) adolescents with whole-brain voxel-wise univariate and task-related functional connectivity analyses. Results Older ASD and TYP showed reduced activation in sensory and premotor areas relative to younger ones. The older ASD group showed reduced left parietal activation relative to TYP. Functional connectivity analyses showed a significant age by group interaction with the older ASD group exhibiting increased functional connectivity strength between the ventrolateral prefrontal cortex (VLPFC) and the anterior cingulate cortex (ACC), bilaterally. This functional connectivity strength was related to task performance in ASD, whereas that between DLPFC and parietal cortex (BA 9 and BA 40) was related to task performance in TYP. Conclusions Adolescents with ASD rely more on “reactive” cognitive control, involving last minute conflict detection and control implementation by the ACC and VLPFC, versus “proactive” cognitive control requiring processing by DLPFC and parietal cortex. Findings await replication in larger longitudinal studies that examine their functional consequences and amenability to intervention. PMID:24209777
NASA Astrophysics Data System (ADS)
Teo, S.-K.; Wong, S. T.; Tan, M. L.; Su, Y.; Zhong, L.; Tan, Ru-San
2015-03-01
After surgical repair for Tetralogy of Fallot (TOF), most patients experience long-term complications as the right ventricle (RV) undergoes progressive remodeling that eventually affect heart functions. Thus, post-repair surgery is required to prevent further deterioration of RV functions that may result in malignant ventricular arrhythmias and mortality. The timing of such post-repair surgery therefore depends crucially on the quantitative assessment of the RV functions. Current clinical indices for such functional assessment measure global properties such as RV volumes and ejection fraction. However, these indices are less than ideal as regional variations and anomalies are obscured. Therefore, we sought to (i) develop a quantitative method to assess RV regional function using regional ejection fraction (REF) based on a 13-segment model, and (ii) evaluate the effectiveness of REF in discriminating 6 repaired TOF patients and 6 normal control based on cardiac magnetic resonance (CMR) imaging. We observed that the REF for the individual segments in the patient group is significantly lower compared to the control group (P < 0.05 using a 2-tail student t-test). In addition, we also observed that the aggregated REF at the basal, mid-cavity and apical regions for the patient group is significantly lower compared to the control group (P < 0.001 using a 2-tail student t-test). The results suggest that REF could potentially be used as a quantitative index for assessing RV regional functions. The computational time per data set is approximately 60 seconds, which demonstrates our method's clinical potential as a real-time cardiac assessment tool.
Toffoletto, Simone; Lanzenberger, Rupert; Gingnell, Malin; Sundström-Poromaa, Inger; Comasco, Erika
2014-12-01
Ovarian hormones are pivotal for the physiological maintenance of the brain function as well as its response to environmental stimuli. There is mounting evidence attesting the relevance of endogenous ovarian hormones as well as exogenous estradiol and progesterone for emotional and cognitive processing. The present review systematically summarized current knowledge on sex steroid hormonal modulation of neural substrates of emotion and cognition revealed by functional magnetic resonance imaging (fMRI). Twenty-four studies of healthy naturally cycling and combined oral contraceptives (COC) user women, or women undergoing experimental manipulations, during their reproductive age, were included. Furthermore, six studies of premenstrual dysphoric disorder (PMDD), a hormonally based mood disorder, and three of gender dysphoria (GD), which provides an intriguing opportunity to examine the effect of high-dose cross-sex hormone therapy (CSHT) on brain functioning, were included. Globally, low (early follicular and the entire follicular phase for estrogen and progesterone, respectively) and high (COC, CSHT, late follicular and luteal phase for estrogen; COC, mid- and late-luteal phase for progesterone) hormonal milieu diversely affected the response of several brain regions including the amygdala, anterior cingulate cortex, and inferior frontal gyrus, but their functional recruitment across groups and domains was scattered. The constellation of findings provides initial evidence of the influence of sex steroid hormones on cortical and subcortical regions implicated in emotional and cognitive processing. Further well-powered and multimodal neuroimaging studies will be needed to identify the neural mechanism of functional brain alterations induced by sex steroid hormones. Copyright © 2014 Elsevier Ltd. All rights reserved.
Weiss, K L; Welsh, R C; Eldevik, P; Bieliauskas, L A; Steinberg, B A
2001-12-01
The authors performed this study to assess brain activation during encoding and successful recall with a declarative memory paradigm that has previously been demonstrated to be effective for teaching students about the cranial nerves. Twenty-four students underwent functional magnetic resonance (MR) imaging during encoding and recall of the name, number, and function of the 12 cranial nerves. The students viewed mnemonic graphic and text slides related to individual nerves, as well as their respective control slides. For the recall paradigm, students were prompted with the numbers 1-12 (test condition) intermixed with the number 14 (control condition). Subjects were tested about their knowledge of cranial nerves outside the MR unit before and after functional MR imaging. Students learned about the cranial nerves while undergoing functional MR imaging (mean post- vs preparadigm score, 8.1 +/- 3.4 [of a possible 12] vs 0.75 +/- 0.94, bilateral prefrontal cortex, left greater than right; P < 2.0 x 10(-12)) and maintained this knowledge at I week. The encoding and recall paradigms elicited distributed networks of brain activation. Encoding revealed statistically significant activation in the bilateral prefrontal cortex, left greater than right [corrected]; bilateral occipital and parietal associative cortices, parahippocampus region, fusiform gyri, and cerebellum. Successful recall activated the left much more than the right prefrontal, parietal associative, and anterior cingulate cortices; bilateral precuneus and cerebellum; and right more than the left posterior cingulate. A predictable pattern of brain activation at functional MR imaging accompanies the encoding and successful recall of the cranial nerves with this declarative memory paradigm.
Ho, S. Shaun; Swain, James E.
2017-01-01
Maternal attachment-related parenting behaviors require mothers to regulate self-related and child-related distress. Emotion regulation is, in turn, influenced by maternal mood and personal developmental history. In the current study we examined how depressive mood may alter maternal limbic system function and functional connectivity underlying defensive and hedonic motivations. Twenty nine mothers were recruited to undergo a baby-cry task during a functional magnetic resonance imaging (fMRI) scan. Based on self-reported depression symptoms and clinical interview, the participants were grouped as healthy controls (n = 15) and currently depressed (n = 14). In the baby-cry task, 30s-long auditory stimuli of baby-cry sounds were presented to simulate four conditions: generic baby-cry (Just-Listen), baby-cry as if it were their own child’s cry (Your-Baby), baby-cry as if it were themselves (Self), and matched control sounds (Noise). Depressed mothers, as compared to healthy controls, showed greater Self versus Just-Listen responses in left extended amygdala and decreased functional coupling between this left extended amygdala as the seed and nucleus accumbens (NAc) in self-oriented (Self versus Just-Listen) and child-oriented (Your-Baby versus Just-Listen) distress signals. Moreover, the extended amygdala’s differential functional connectivity with dorsomedial prefrontal cortex (dmPFC) during the Your-Baby versus Self was increased for depressed mothers and decreased for healthy controls. Thus, depression may affect mothers by increasing baby-cry threat responses and dysregulating associations between threat and heathy child-oriented parenting motivations. These results are discussed in the context of attachment and self-psychology. PMID:28263829
Unique topological characterization of braided magnetic fields
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yeates, A. R.; Hornig, G.
We introduce a topological flux function to quantify the topology of magnetic braids: non-zero, line-tied magnetic fields whose field lines all connect between two boundaries. This scalar function is an ideal invariant defined on a cross-section of the magnetic field, and measures the average poloidal magnetic flux around any given field line, or the average pairwise crossing number between a given field line and all others. Moreover, its integral over the cross-section yields the relative magnetic helicity. Using the fact that the flux function is also an action in the Hamiltonian formulation of the field line equations, we prove thatmore » it uniquely characterizes the field line mapping and hence the magnetic topology.« less
Tokaya, Janot P; Raaijmakers, Alexander J E; Luijten, Peter R; van den Berg, Cornelis A T
2018-04-24
We introduce the transfer matrix (TM) that makes MR-based wireless determination of transfer functions (TFs) possible. TFs are implant specific measures for RF-safety assessment of linear implants. The TF relates an incident tangential electric field on an implant to a scattered electric field at its tip that generally governs local heating. The TM extends this concept and relates an incident tangential electric field to a current distribution in the implant therewith characterizing the RF response along the entire implant. The TM is exploited to measure TFs with MRI without hardware alterations. A model of rightward and leftward propagating attenuated waves undergoing multiple reflections is used to derive an analytical expression for the TM. This allows parameterization of the TM of generic implants, e.g., (partially) insulated single wires, in a homogeneous medium in a few unknowns that simultaneously describe the TF. These unknowns can be determined with MRI making it possible to measure the TM and, therefore, also the TF. The TM is able to predict an induced current due to an incident electric field and can be accurately parameterized with a limited number of unknowns. Using this description the TF is determined accurately (with a Pearson correlation coefficient R ≥ 0.9 between measurements and simulations) from MRI acquisitions. The TM enables measuring of TFs with MRI of the tested generic implant models. The MR-based method does not need hardware alterations and is wireless hence making TF determination in more realistic scenarios conceivable. © 2018 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Seidensticker, Max, E-mail: max.seidensticker@med.ovgu.de; Burak, Miroslaw; Kalinski, Thomas
PurposeRadiotherapy of liver malignancies shows promising results (radioembolization, stereotactic irradiation, interstitial brachytherapy). Regardless of the route of application, a certain amount of nontumorous liver parenchyma will be collaterally damaged by radiation. The functional reserve may be significantly reduced with an impact on further treatment planning. Monitoring of radiation-induced liver damage by imaging is neither established nor validated. We performed an analysis to correlate the histopathological presence of radiation-induced liver damage with functional magnetic resonance imaging (MRI) utilizing hepatobiliary contrast media (Gd-BOPTA).MethodsPatients undergoing local high-dose-rate brachytherapy for whom a follow-up hepatobiliary MRI within 120 days after radiotherapy as well as an evaluablemore » liver biopsy from radiation-exposed liver tissue within 7 days before MRI were retrospectively identified. Planning computed tomography (CT)/dosimetry was merged to the CT-documentation of the liver biopsy and to the MRI. Presence/absence of radiation-induced liver damage (histopathology) and Gd-BOPTA uptake (MRI) as well as the dose applied during brachytherapy at the site of tissue sampling was determined.ResultsFourteen biopsies from eight patients were evaluated. In all cases with histopathological evidence of radiation-induced liver damage (n = 11), no uptake of Gd-BOPTA was seen. In the remaining three, cases no radiation-induced liver damage but Gd-BOPTA uptake was seen. Presence of radiation-induced liver damage and absence of Gd-BOPTA uptake was correlated with a former high-dose exposition.ConclusionsAbsence of hepatobiliary MRI contrast media uptake in radiation-exposed liver parenchyma may indicate radiation-induced liver damage. Confirmatory studies are warranted.« less
Harnessing electrical power from vortex-induced vibration of a circular cylinder
NASA Astrophysics Data System (ADS)
Soti, Atul Kumar; Thompson, Mark C.; Sheridan, John; Bhardwaj, Rajneesh
2017-04-01
The generation of electrical power from Vortex-Induced Vibration (VIV) of a cylinder is investigated numerically. The cylinder is free to oscillate in the direction transverse to the incoming flow. The cylinder is attached to a magnet that can move along the axis of a coil made from conducting wire. The magnet and the coil together constitute a basic electrical generator. When the cylinder undergoes VIV, the motion of the magnet creates a voltage across the coil, which is connected to a resistive load. By Lenz's law, induced current in the coil applies a retarding force to the magnet. Effectively, the electrical generator applies a damping force on the cylinder with a spatially varying damping coefficient. For the initial investigation reported here, the Reynolds number is restricted to Re < 200, so that the flow is laminar and two-dimensional (2D). The incompressible 2D Navier-Stokes equations are solved using an extensively validated spectral-element based solver. The effects of the electromagnetic (EM) damping constant xi_m, coil dimensions (radius a, length L), and mass ratio on the electrical power extracted are quantified. It is found that there is an optimal value of xi_m (xi_opt) at which maximum electrical power is generated. As the radius or length of the coil is increased, the value of xi_opt is observed to increase. Although the maximum average power remains the same, a larger coil radius or length results in a more robust system in the sense that a relatively large amount of power can be extracted when xi_m is far from xi_opt, unlike the constant damping ratio case. The average power output is also a function of Reynolds number, primarily through the increased maximum oscillation amplitude that occurs with increased Reynolds number at least within the laminar range, although the general qualitative findings seem likely to carry across to high Reynolds number VIV.
Zeni, Joseph A; Axe, Michael J; Snyder-Mackler, Lynn
2010-05-06
Arthritis is a leading cause of disability in the United States. Total knee arthroplasty (TKA) has become the gold standard to manage the pain and disability associated with knee osteoarthritis (OA). Although more than 400,000 primary TKA surgeries are performed each year in the United States, not all individuals with knee OA elect to undergo the procedure. No clear consensus exists on criteria to determine who should undergo TKA. The purpose of this study was to determine which clinical factors will predict the decision to undergo TKA in individuals with end-stage knee OA. Knowledge of these factors will aid in clinical decision making for the timing of TKA. Functional data from one hundred twenty persons with end-stage knee OA were obtained through a database. All of the individuals complained of knee pain during daily activities and had radiographic evidence of OA. Functional and clinical tests, collectively referred to as the Delaware Osteoarthritis Profile, were completed by a physical therapist. This profile consisted of measuring height, weight, quadriceps strength and active knee range of motion, while functional mobility was assessed using the Timed Up and Go (TUG) test and the Stair Climbing Task (SCT). Self-perceived functional ability was measured using the activities of daily living subscale of the Knee Outcome Survey (KOS-ADLS). A logistic regression model was used to identify variables predictive of TKA use. Forty subjects (33%) underwent TKA within two years of evaluation. These subjects were significantly older and had significantly slower TUG and SCT times (p < 0.05). Persons that underwent TKA were also significantly weaker, had lower self-reported function and had less knee extension than persons who did not undergo TKA. No differences between groups were seen for BMI, gender, knee flexion ROM and unilateral versus bilateral joint disease. Using backward regression, age, knee extension ROM and KOS-ADLS together significantly predicted whether or not a person would undergo TKA (p
Frontal glutamate and reward processing in adolescence and adulthood.
Gleich, Tobias; Lorenz, Robert C; Pöhland, Lydia; Raufelder, Diana; Deserno, Lorenz; Beck, Anne; Heinz, Andreas; Kühn, Simone; Gallinat, Jürgen
2015-11-01
The fronto-limbic network interaction, driven by glutamatergic and dopaminergic neurotransmission, represents a core mechanism of motivated behavior and personality traits. Reward seeking behavior undergoes tremendous changes in adolescence paralleled by neurobiological changes of this network including the prefrontal cortex, striatum and amygdala. Since fronto-limbic dysfunctions also underlie major psychiatric diseases beginning in adolescence, this investigation focuses on network characteristics separating adolescents from adults. To investigate differences in network interactions, the brain reward system activity (slot machine task) together with frontal glutamate concentration (anterior cingulate cortex, ACC) was measured in 28 adolescents and 26 adults employing functional magnetic resonance imaging and magnetic resonance spectroscopy, respectively. An inverse coupling of glutamate concentrations in the ACC and activation of the ventral striatum was observed in adolescents. Further, amygdala response in adolescents was negatively correlated with the personality trait impulsivity. For adults, no significant associations of network components or correlations with impulsivity were found. The inverse association between frontal glutamate concentration and striatal activation in adolescents is in line with the triadic model of motivated behavior stressing the important role of frontal top-down inhibition on limbic structures. Our data identified glutamate as the mediating neurotransmitter of this inhibitory process and demonstrates the relevance of glutamate on the reward system and related behavioral traits like impulsivity. This fronto-limbic coupling may represent a vulnerability factor for psychiatric disorders starting in adolescence but not in adulthood.
Prestes, Rosilene A; Colnago, Luiz A; Forato, Lucimara A; Carrilho, Emanuel; Bassanezi, Renato B; Wulff, Nelson A
2009-01-01
Citrus sudden death (CSD) is a new disease of sweet orange and mandarin trees grafted on Rangpur lime and Citrus volkameriana rootstocks. It was first seen in Brazil in 1999, and has since been detected in more than four million trees. The CSD causal agent is unknown and the current hypothesis involves a virus similar to Citrus tristeza virus or a new virus named Citrus sudden death-associated virus. CSD symptoms include generalized foliar discoloration, defoliation and root death, and, in most cases, it can cause tree death. One of the unique characteristics of CSD disease is the presence of a yellow stain in the rootstock bark near the bud union. This region also undergoes profound anatomical changes. In this study, we analyse the metabolic disorder caused by CSD in the bark of sweet orange grafted on Rangpur lime by nuclear magnetic resonance (NMR) spectroscopy and imaging. The imaging results show the presence of a large amount of non-functional phloem in the rootstock bark of affected plants. The spectroscopic analysis shows a high content of triacylglyceride and sucrose, which may be related to phloem blockage close to the bud union. We also propose that, without knowing the causal CSD agent, the determination of oil content in rootstock bark by low-resolution NMR can be used as a complementary method for CSD diagnosis, screening about 300 samples per hour.
Musa, Tarique Al; Plein, Sven; Greenwood, John P
2016-06-01
Degenerative aortic stenosis (AS) is the most common valvular disease in the western world with a prevalence expected to double within the next 50 years. International guidelines advocate the use of cardiovascular magnetic resonance (CMR) as an investigative tool, both to guide diagnosis and to direct optimal treatment. CMR is the reference standard for quantifying both left and right ventricular volumes and mass, which is essential to assess the impact of AS upon global cardiac function. Given the ability to image any structure in any plane, CMR offers many other diagnostic strengths including full visualisation of valvular morphology, direct planimetry of orifice area, the quantification of stenotic jets and in particular, accurate quantification of valvular regurgitation. In addition, CMR permits reliable and accurate measurements of the aortic root and arch which can be fundamental to appropriate patient management. There is a growing evidence base to indicate tissue characterisation using CMR provides prognostic information, both in asymptomatic AS patients and those undergoing intervention. Furthermore, a number of current clinical trials will likely raise the importance of CMR in routine patient management. This article will focus on the incremental value of CMR in the assessment of severe AS and the insights it offers following valve replacement.
Young, Michael C.; Theis, Jake R.; Hodges, James S.; Dunn, Ty B.; Pruett, Timothy L.; Chinnakotla, Srinath; Walker, Sidney P.; Freeman, Martin L.; Trikudanathan, Guru; Arain, Mustafa; Robertson, R. Paul; Wilhelm, Joshua J.; Schwarzenberg, Sarah J.; Bland, Barbara; Beilman, Gregory J.; Bellin, Melena D.
2015-01-01
Objectives About two-thirds of patients will remain on insulin therapy after total pancreatectomy with islet autotransplant (TPIAT) for chronic pancreatitis. We investigated the relationship between measured pancreas volume on computerized tomography (CT) or magnetic resonance imaging (MRI), and features of chronic pancreatiits on imaging, with subsequent islet isolation and diabetes outcomes. Methods CT or MRI was reviewed for pancreas volume (Vitrea software), and presence or absence of calcifications, atrophy, and dilated pancreatic duct in 97 patients undergoing TPIAT. Relationship between these features and: (1) islet mass isolated and (2) diabetes status at 1 year post-TPAIT were evaluated. Results Pancreas volume correlated with islet mass measured as total islet equivalents (r=0.50, p<0.0001). Mean islet equivalents was reduced by more than half if any one of calcifications, atrophy, or ductal dilatation were observed. Pancreatic calcifications increased the odds of insulin dependence 4.0 fold (1.1, 15). Collectively, the pancreas volume and 3 imaging features strongly associated with 1 year insulin use (p=0.07), islet graft failure (p=0.003), Hemoglobin A1c (p=0.0004), fasting glucose (p=0.027), and fasting C-peptide level (p=0.008). Conclusions Measures of pancreatic parenchymal destruction on imaging, including smaller pancreas volume and calcifications associate strongly with impaired islet mass and 1 year diabetes outcomes. PMID:26745861
Kahokehr, Arman A; Selph, John P; Belsante, Michael J; Bashir, Mustafa; Sofue, Keitaro; Tausch, Timothy J; Brand, Timothy C; Lloyd, Jessica C; Goldsmith, Zachariah G; Walter, Jack R; Peterson, Andrew C
2018-06-01
To compare the length of the membranous (functional) urethra in male patients who underwent the male transobturator sling (TOS) for postradical prostatectomy urinary incontinence (PPI). The TOS is in established use for treatment of PPI; however, the precise mechanism of action is unknown. This is a prospective case-controlled study on men undergoing male TOS surgery from 2008 to 2014. The comparison arm included patients without incontinence after radical prostatectomy. All participants underwent dynamic magnetic resonance imaging (MRI) at baseline and this was repeated after TOS placement for those who underwent the procedure. Three standardized points were measured using MRI and compared in both groups in addition to clinical measures. Thirty-nine patients were enrolled and 31 patients completed the protocols. The controls (N = 14) had a longer vesicourethral anastomosis to urethra measured at the penile bulb (functional urethral length) distance compared to the pre-TOS group at rest (1.92 cm controls vs 1.27 cm pre-TOS, P = .0018) and at Valsalva (2.13 cm controls vs 1.72 cm pre-TOS, P = .0371). Placement of the sling (N = 17) increased the functional urethral length distance at rest (1.92 cm control vs 1.53 cm post-TOS, P = .09) and at Valsalva (1.94 cm post-TOS vs 2.13 cm control, P = .61), so that the difference was no longer statistically significant. We identified that one possible mechanism in improvement in stress urinary incontinence post-TOS placement is the lengthening of the vesicourethral anastomosis to bulbar-urethra distance. This is the first such study utilizing dynamics MRI in post prostatectomy controls, incontinent pre-TOS, and post-TOS to assess and show these findings. Copyright © 2018 Elsevier Inc. All rights reserved.
Orvets, Nathan D.; Parisien, Robert L.; Curry, Emily J.; Chung, Justin S.; Eichinger, Josef K.; Murakami, Akira M.; Li, Xinning
2017-01-01
Background: The delayed management of patients with shoulder instability may increase the prevalence and severity of concomitant intra-articular shoulder injuries resulting from persistent subluxations and dislocations. Hypothesis: Patients with a longer delay from the initial dislocation event to undergoing magnetic resonance imaging (MRI) or magnetic resonance arthrography will demonstrate more subluxations or dislocations and a greater amount of intra-articular shoulder damage. Study Design: Cohort study; Level of evidence, 3. Methods: We performed a retrospective review of 89 patients from a single institution with clinically and radiographically confirmed primary traumatic anterior shoulder dislocations. Patients were divided into 2 groups: those undergoing MRI less than 6 months (n = 44; LT6) or greater than 6 months (n = 45; GT6) from the initial dislocation event. The MRI assessment included evaluation of soft tissue injuries, including the labrum, capsule, rotator cuff, and cartilage damage severity along with bone loss. Results: The delayed MRI group (GT6) demonstrated a greater degree of intra-articular abnormalities compared to the early MRI group (LT6). A greater percentage of superior labral anterior-posterior (SLAP) tears (58% vs 34%, respectively) and cartilage damage (73% vs 27%, respectively) was present in the GT6 group compared to the LT6 group. Cartilage damage was 18% mild, 7% moderate, and 2% severe for the LT6 group as compared to 38% mild, 31% moderate, and 4% severe for the GT6 group. Additionally, more recurrent shoulder dislocations were seen in the GT6 group (n = 6) compared to the LT6 group (n = 2). In the LT6 group, there were more rotator cuff tears (50% vs 24%, respectively) and capsular tears (25% vs 9%, respectively) than the GT6 group. There was no difference in anterior glenoid bone loss, glenoid version, or humeral head subluxation between the 2 groups. Conclusion: Patients who undergo MRI greater than 6 months from the time of primary or initial shoulder dislocation had significantly more recurrent shoulder instability events and demonstrated a greater incidence and severity of intra-articular abnormalities, including SLAP tears, posterior labral tears, and anterior glenoid cartilage damage. PMID:28975132
Vivas, Esther X; Carlson, Matthew L; Neff, Brian A; Shepard, Neil T; McCracken, D Jay; Sweeney, Alex D; Olson, Jeffrey J
2018-02-01
Does intraoperative facial nerve monitoring during vestibular schwannoma surgery lead to better long-term facial nerve function? This recommendation applies to adult patients undergoing vestibular schwannoma surgery regardless of tumor characteristics. Level 3: It is recommended that intraoperative facial nerve monitoring be routinely utilized during vestibular schwannoma surgery to improve long-term facial nerve function. Can intraoperative facial nerve monitoring be used to accurately predict favorable long-term facial nerve function after vestibular schwannoma surgery? This recommendation applies to adult patients undergoing vestibular schwannoma surgery. Level 3: Intraoperative facial nerve can be used to accurately predict favorable long-term facial nerve function after vestibular schwannoma surgery. Specifically, the presence of favorable testing reliably portends a good long-term facial nerve outcome. However, the absence of favorable testing in the setting of an anatomically intact facial nerve does not reliably predict poor long-term function and therefore cannot be used to direct decision-making regarding the need for early reinnervation procedures. Does an anatomically intact facial nerve with poor electromyogram (EMG) electrical responses during intraoperative testing reliably predict poor long-term facial nerve function? This recommendation applies to adult patients undergoing vestibular schwannoma surgery. Level 3: Poor intraoperative EMG electrical response of the facial nerve should not be used as a reliable predictor of poor long-term facial nerve function. Should intraoperative eighth cranial nerve monitoring be used during vestibular schwannoma surgery? This recommendation applies to adult patients undergoing vestibular schwannoma surgery with measurable preoperative hearing levels and tumors smaller than 1.5 cm. Level 3: Intraoperative eighth cranial nerve monitoring should be used during vestibular schwannoma surgery when hearing preservation is attempted. Is direct monitoring of the eighth cranial nerve superior to the use of far-field auditory brain stem responses? This recommendation applies to adult patients undergoing vestibular schwannoma surgery with measurable preoperative hearing levels and tumors smaller than 1.5 cm. Level 3: There is insufficient evidence to make a definitive recommendation. The full guideline can be found at: https://www.cns.org/guidelines/guidelines-manage-ment-patients-vestibular-schwannoma/chapter_4. Copyright © 2017 by the Congress of Neurological Surgeons
Pronounced pre-martensitic anomaly in the magnetization on Ni2MnGa thin films
NASA Astrophysics Data System (ADS)
Neckel, I. T.; Müller, C.; Nobrega, K. Z.; Dartora, C. A.; Schreiner, W. H.; Mosca, D. H.
2018-05-01
We have prepared [110]-textured Ni2MnGa thin films exhibiting an unusual pre-martensitic transition accompanied by an extremely large magnetization change. The thin films were grown by molecular beam epitaxy directly on epi-ready GaAs(111)B. Crystalline structure was investigated in situ by reflection high-energy electron diffraction (RHEED) and ex situ by x-ray diffraction (XRD) and transmission electron microscopy (TEM). The results show that the film exhibits cubic crystalline structure (L2 1) at room temperature with lattice parameter a = 5.88 Å which undergoes martensitic transition. Magnetic characterization shows ferromagnetic behavior at room temperature with Curie temperature higher than room temperature. Martensitic transformation occurs at TM ∼ 185 K. A phenomenological model based on Landau theory of phase transformation was developed to explain the anomalous pre-martensitic transition at ∼285 K.
Microwave-Assisted Synthesis, Microstructure, and Magnetic Properties of Rare-Earth Cobaltites.
Gutiérrez Seijas, Julia; Prado-Gonjal, Jesús; Ávila Brande, David; Terry, Ian; Morán, Emilio; Schmidt, Rainer
2017-01-03
The series of perovskite rare-earth (RE) doped cobaltites (RE)CoO 3 (RE = La-Dy) was prepared by microwave-assisted synthesis. The crystal structure undergoes a change of symmetry depending on the size of the RE cation. LaCoO 3 is rhombohedral, S.G. R3̅c (No. 167), while, for the rest of the RE series (Pr-Dy), the symmetry is orthorhombic, S.G. Pnma (No. 62). The crystal structure obtained by X-ray diffraction was confirmed by high-resolution transmission electron microscopy, which yielded a good match between experimental and simulated images. It is further shown that the well-known magnetism in LaCoO 3 , which involves a thermally induced Co 3+ (d 6 ) low spin to intermediate or high spin state transition, is strongly modified by the RE cation, and a rich variety of magnetic order has been detected across the series.
Magnetic orders of LaTiO3 under epitaxial strain: A first-principles study
NASA Astrophysics Data System (ADS)
Weng, Yakui; Huang, Xin; Tang, Yankun; Dong, Shuai
2014-05-01
Perovskite LaTiO3 bulk is a typical Mott-insulator with G-type antiferromagnetic order. In this work, the biaxial strain effects on the ground magnetic order of LaTiO3 films grown on various substrates have been studied. For the compressive strain, LaTiO3 films grown on LaAlO3, LaGaO3, and SrTiO3 substrates undergo a phase transition from the original G-type antiferromagnet to A-type antiferromagnet. The underlying physical mechanisms are the lattice distortions tunned by strain. While for the tensile strain, the BaTiO3 and LaScO3 substrates have been tested, which show a tendency to transit the LaTiO3 to the C-type antiferromagnet. Furthermore, our calculations find that the magnetic transitions under epitaxial strain do not change the insulating fact of LaTiO3.
NASA Astrophysics Data System (ADS)
Niu, Q.; Yu, W. C.; Yip, K. Y.; Lim, Z. L.; Kotegawa, H.; Matsuoka, E.; Sugawara, H.; Tou, H.; Yanase, Y.; Goh, Swee K.
2017-06-01
In conventional metals, modification of electron trajectories under magnetic field gives rise to a magnetoresistance that varies quadratically at low field, followed by a saturation at high field for closed orbits on the Fermi surface. Deviations from the conventional behaviour, for example, the observation of a linear magnetoresistance, or a non-saturating magnetoresistance, have been attributed to exotic electron scattering mechanisms. Recently, linear magnetoresistance has been observed in many Dirac materials, in which the electron-electron correlation is relatively weak. The strongly correlated helimagnet CrAs undergoes a quantum phase transition to a nonmagnetic superconductor under pressure. Here we observe, near the magnetic instability, a large and non-saturating quasilinear magnetoresistance from the upper critical field to 14 T at low temperatures. We show that the quasilinear magnetoresistance may arise from an intricate interplay between a nontrivial band crossing protected by nonsymmorphic crystal symmetry and strong magnetic fluctuations.
Frustrated spin one on a diamond lattice in NiRh2O4
NASA Astrophysics Data System (ADS)
Chamorro, J. R.; Ge, L.; Flynn, J.; Subramanian, M. A.; Mourigal, M.; McQueen, T. M.
2018-03-01
We report the discovery of a spin one diamond lattice in NiRh2O4 . This spinel undergoes a cubic to tetragonal phase transition at T =440 K that leaves all nearest neighbor interactions equivalent. In the tetragonal phase, magnetization measurements show a Ni2 + effective moment of peff=3.3 (1 ) and dominant antiferromagnetic interactions with ΘCW=-11.3 (7 ) K. No phase transition to a long-range magnetically ordered state is observed by specific heat measurements down to T =0.1 K. Inelastic neutron scattering measurements on substoichiometric NiRh2O4 reveal possible valence-bond behavior and show no visible signs of magnetic ordering. NiRh2O4 provides a platform on which to explore the previously unknown and potentially rich physics of spin one interacting on the diamond lattice, including the realization of theoretically predicted quantum spin liquid and topological paramagnet states.
Kim, Man Soo; Koh, In Jun; Choi, Young Jun; Pak, Kyu Hyung; In, Yong
2017-07-01
The quality of cartilage repair after marrow stimulation is unpredictable. To overcome the shortcomings of the microfracture technique, various augmentation techniques have been developed. However, their efficacies remain unclear. The quality of cartilage repair and clinical outcomes would be superior in patients undergoing high tibial osteotomy (HTO) with microfracture and collagen augmentation compared to those undergoing HTO with microfracture alone without collagen augmentation for the treatment of medial compartment osteoarthritis (OA) of the knee. Randomized controlled trial; Level of evidence, 2. Twenty-eight patients undergoing HTO were randomized into 2 groups: microfracture alone (group 1, n = 14) or microfracture with collagen augmentation (group 2, n = 14). At 1 year postoperatively, second-look arthroscopic surgery and biopsy of repaired cartilage were performed at the time of HTO plate removal. Biopsy specimens were graded using the International Cartilage Repair Society Visual Assessment Scale II (ICRS II). In addition, imaging outcomes in terms of the magnetic resonance observation of cartilage repair tissue (MOCART) score were assessed based on magnetic resonance imaging (MRI). Finally, clinical outcomes in terms of the visual analog scale (VAS) for pain score, Knee Injury and Osteoarthritis Outcome Score (KOOS), International Knee Documentation Committee (IKDC) score, and Tegner activity scale score were evaluated. The mean ICRS II score in group 2 was significantly higher than that in group 1 (1053.2 vs 885.4, respectively; P = .002). Group 2 showed greater improvement in tissue morphology, cell morphology, surface architecture, middle/deep zone assessment, and overall assessment compared with group 1 ( P < .050 for all comparisons). Imaging outcomes based on the MOCART score were superior in group 2 compared to those in group 1 on MRI at 1 year postoperatively (64.6 vs 45.4, respectively; P = .001). The degree of defect repair was better in group 2 than in group 1 ( P = .040). Clinical outcomes in terms of the VAS for pain score, KOOS, IKDC score, and Tegner activity scale score were improved in both groups without between-group differences ( P > .100 for all comparisons). The quality of cartilage repair after microfracture with collagen augmentation was superior to that after microfracture alone in patients undergoing HTO. Clinical results after 1 year did not reflect this difference in tissue repair. Therefore, a longer follow-up of the cohort is needed to answer this question.
NASA Technical Reports Server (NTRS)
Britcher, Colin P.
1997-01-01
This paper will briefly review previous work in wind tunnel Magnetic Suspension and Balance Systems (MSBS) and will examine the handful of systems around the world currently known to be in operational condition or undergoing recommissioning. Technical developments emerging from research programs at NASA and elsewhere will be reviewed briefly, where there is potential impact on large-scale MSBSS. The likely aerodynamic applications for large MSBSs will be addressed, since these applications should properly drive system designs. A recently proposed application to ultra-high Reynolds number testing will then be addressed in some detail. Finally, some opinions on the technical feasibility and usefulness of a large MSBS will be given.
Optical textile tests MRI patients from afar
NASA Astrophysics Data System (ADS)
Gould, Paula
2008-11-01
Researchers in Europe have developed a wearable textile fitted with optical sensors that could be used to remotely monitor a patient's breathing patterns while they undergo magnetic resonance imaging (MRI) scans. The new textile will allow medical staff to keep an eye on children and other vulnerable patients who often have to be calmed with sedatives or anaesthetic drugs to keep them still during a scan. The technique will be particularly useful if proposed European Union (EU) legislation that is designed to protect medical staff from being exposed to the high magnetic fields of MRI systems comes into force in 2012. The new rules would prevent nurses from being in the room where the scan is taking place.
A reexamination of pitch angle diffusion of electrons at the boundary of the lunar wake
NASA Astrophysics Data System (ADS)
Nakagawa, T.; Iizima, M.
2006-05-01
Velocity distribution of the solar wind electrons injected into the lunar wake boundary is re-examined by using a simple model structure of inward electric field. The electrons that were flowing along the magnetic field lines undergo pitch angle scattering due to the electric field component perpendicular to the magnetic field. The electrons obtain perpendicular speeds twice as much as the drift speed. On the basis of the GEOTAIL observations of the whistler mode waves and strahl electrons, the intensity of the electric field and the thickness of the wake structure are estimated to be 28-40 mVm-1 and less than 20 km, respectively.
Anisotropic magnetocaloric effect in HoAlGa polycrystalline compound
NASA Astrophysics Data System (ADS)
Yan, Zhang; Xinqi, Zheng; JieFu, Xiong; Shulan, Zuo; Qiaoyan, Dong; Tongyun, Zhao; Baogen, Shen
2018-05-01
In this work, a nonnegligible anisotropic magnetocaloric effect (MCE) in HoAlGa polycrystalline compounds has been observed. With temperature increasing, the HoAlGa compound undergoes two kinds of magnetic transitions at 19 K and 31 K, respectively, the later has been recognized as an ordinary antiferromagnetic to paramagnetic (AFM-PM) transition. The -ΔS peak of HoAGa reaches 5.4 J/kg K and 1.5 J/kg K at 35 K along parallel and perpendicular texture directions respectively, for a field change of 0-5 T. The result indicates that the HoAlGa polycrystalline compounds with excellent anisotropic MCE can be expected to have effective magnetic refrigeration applications in low temperature range.