DOE Office of Scientific and Technical Information (OSTI.GOV)
Elliott, G.R.B.; Vanderborgh, N.E.
Experimental and theoretical analyses show that uncontrolled water invasion during underground coal conversion (UCC) is harmful at all stages of UCC. By contrast, if water invasion is prevented, coal porosity can be created for further processing, pyrolysis can yield uniform hydrocarbon products, gasification can produce a uniform product, coal is fully consumed (not bypassed) during combustion, and environmental problems are minimized. In all cases the experimental results are supportive of the theory of underground coal processing presented. We see no insurmountable technical problems existing for a staged underground coal conversion process, but we emphasize that all concepts in underground coalmore » processing depend critically upon control of water influx. It is important that techniques for measuring and controlling water flow be developed if this technology is to make a contribution to the Nation's energy supply.« less
Underground thermal generation of hydrocarbons from dry, southwestern coals
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vanderborgh, N.E.; Elliott, G.R.B.
1978-01-01
The LASL underground coal conversion concept produces intermediate-BTU fuel gas for nearby industries such as ''minemouth'' electric power plants, plus major byproducts in the form of liquid and gaseous hydrocarbons for feedstocks to chemical plants e.g., substitute natural gas (SNG) producers. The concept involves controlling the water influx and drying the coal, generating hydrocarbons, by pyrolysis and finally gasifying the residual char with O/sub 2//CO/sub 2/ or air/CO/sub 2/ mixtures to produce industrial fuel gases. Underground conversion can be frustrated by uncontrolled water in the coal bed. Moisture can (a) prevent combustion, (b) preclude fuel gas formation by lowering reactionmore » zone temperatures and creating kinetic problems, (c) ruin product gas quality by dropping temperatures into a thermodynamically unsatisfactory regime, (d) degrade an initially satisfactory fuel gas by consuming carbon monoxide, (e) waste large amounts of heat, and (f) isolate reaction zones so that the processing will bypass blocks of coal.« less
NASA Astrophysics Data System (ADS)
McNeese, L. E.
1981-12-01
The progress made during the period from July 1 through September 30 for the Oak Ridge National Laboratory research and development projects in support of the increased utilization of coal and other fossil fuels as sources of clean energy is reported. The following topics are discussed: coal conversion development, chemical research and development, materials technology, fossil energy materials program, liquefaction projects, component development, process analysis, environmental control technology, atmospheric fluidized bed combustion, underground coal gasification, coal preparation and waste utilization.
Clean Power Generation from the Intractable Natural Coalfield Fires: Turn Harm into Benefit.
Shi, Bobo; Su, Hetao; Li, Jinshi; Qi, Haining; Zhou, Fubao; Torero, José L; Chen, Zhongwei
2017-07-13
The coal fires, a global catastrophe for hundreds of years, have been proved extremely difficult to control, and hit almost every coal-bearing area globally. Meanwhile, underground coal fires contain tremendous reservoir of geothermal energy. Approximately one billion tons of coal burns underground annually in the world, which could generate ~1000 GW per annum. A game-changing approach, environmentally sound thermal energy extraction from the intractable natural coalfield fires, is being developed by utilizing the waste energy and reducing the temperature of coalfield fires at the same time. Based on the Seebeck effect of thermoelectric materials, the temperature difference between the heat medium and cooling medium was employed to directly convert thermal energy into clean electrical energy. By the time of December 2016, the power generation from a single borehole at Daquan Lake fire district in Xinjiang has been exceeded 174.6 W. The field trial demonstrates that it is possible to exploit and utilize the waste heat resources in the treated coal fire areas. It promises a significant impact on the structure of global energy generation and can also promote progress in thermoelectric conversion materials, geothermal exploration, underground coal fires control and other energy related areas.
Noll, James; Gilles, Stewart; Wu, Hsin Wei; Rubinstein, Elaine
2015-01-01
In the United States, total carbon (TC) is used as a surrogate for determining diesel particulate matter (DPM) compliance exposures in underground metal/nonmetal mines. Since TC can be affected by interferences and elemental carbon (EC) is not, one method used to estimate the TC concentration is to multiply the EC concentration from the personal sample by a conversion factor to avoid the influence of potential interferences. Since there is no accepted single conversion factor for all metal/nonmetal mines, one is determined every time an exposure sample is taken by collecting an area sample that represents the TC/EC ratio in the miner's breathing zone and is away from potential interferences. As an alternative to this procedure, this article investigates the relationship between TC and EC from DPM samples to determine if a single conversion factor can be used for all metal/nonmetal mines. In addition, this article also investigates how well EC represents DPM concentrations in Australian coal mines since the recommended exposure limit for DPM in Australia is an EC value. When TC was predicted from EC values using a single conversion factor of 1.27 in 14 US metal/nonmetal mines, 95% of the predicted values were within 18% of the measured value, even at the permissible exposure limit (PEL) concentration of 160 μg/m3 TC. A strong correlation between TC and EC was also found in nine underground coal mines in Australia. PMID:25380085
Method for in situ biological conversion of coal to methane
Volkwein, Jon C.
1995-01-01
A method and apparatus are provided for the in situ biological conversion of coal to methane comprising culturing on a coal-containing substrate a consortium of microorganisms capable of degrading the coal into methane under suitable conditions. This consortium of microorganisms can be obtained from an underground cavity such as an abandoned mine which underwent a change from being supplied with sewage to where no sewage was present, since these conditions have favored the development of microorganisms capable of using coal as a carbon source and converting coal to methane. The consortium of microorganisms obtained from such abandoned coal mines can be isolated and introduced to hard-to-reach coal-containing substrates which lack such microorganisms and which would otherwise remain unrecoverable. The present invention comprises a significant advantage in that useable energy can be obtained from a number of abandoned mine sites or other areas wherein coal is no longer being recovered, and such energy can be obtained in a safe, efficient, and inexpensive manner.
Skubacz, Krystian; Wojtecki, Łukasz; Urban, Paweł
2016-10-01
In Polish underground mines, hazards caused by enhanced natural radioactivity occur. The sources of radiation exposure are short-lived radon decay products, mine waters containing radium 226 Ra and 228 Ra and the radioactive sediments that can precipitate out of these waters. For miners, the greatest exposure is usually due to short-lived radon decay products. The risk assessment is based on the measurement of the total potential alpha energy concentration (PAEC) and the evaluation of the related dose by using the dose conversion factor as recommended by relevant legal requirements. This paper presents the results of measurements of particle size distributions of ambient aerosols in an underground hard coal mine, the assessment of the radioactive particle size distribution of the short-lived radon decay products and the corresponding values of dose conversion factors. The measurements of the ambient airborne particle size distribution were performed in the range from a few nanometers to about 20 μm. The study therefore included practically the whole class of respirable particles. The results showed that the high concentration of ultrafine and fine aerosols measured can significantly affect the value of the dose conversion factors, and consequently the corresponding committed effective dose, to which the miners can be exposed. Copyright © 2016 Elsevier Ltd. All rights reserved.
Global Development of Commercial Underground Coal Gasification
NASA Astrophysics Data System (ADS)
Blinderman, M. S.
2017-07-01
Global development of Underground Coal Gasification (UCG) is considered here in light of latest trends of energy markets and environmental regulations in the countries that have been traditional proponents of UCG. The latest period of UCG development triggered by initial success of the Chinchilla UCG project (1997-2006) has been characterized by preponderance of privately and share-market funded developments. The deceleration of UCG commercialization has been in part caused by recent significant decrease of world oil, gas and coal prices. Another substantial factor was lack of necessary regulations governing extraction and conversion of coal by UCG method in the jurisdictions where the UCG projects were proposed and developed. Along with these objective causes there seem to have been more subjective and technical reasons for a slowdown or cancelation of several significant UCG projects, including low efficiency, poor environmental performance, and inability to demonstrate technology at a sufficient scale and/or at a competitive cost. Latest proposals for UCG projects are briefly reviewed.
Underground Coal Preparation System and Applications
NASA Astrophysics Data System (ADS)
Wei, Cao; DeYong, Shang; BaoNing, Zhang
2018-03-01
The underground coal preparation is a cutting-edge technology of the coal industry worldwide. This paper introduced the meaning of implementing the underground coal preparation, and the practical applications of underground mechanical moving screen jig, underground heavy medium shallow slot and underground air jigger. Through analyzing the main separation equipment and the advantages and disadvantages of three primary processes from aspects of process complexity, slime water treatment, raw coal preparation, etc., the difference among technology investment, construction scale, production cost and economic benefit is concluded.
30 CFR 75.1907 - Diesel-powered equipment intended for use in underground coal mines.
Code of Federal Regulations, 2011 CFR
2011-07-01
... underground coal mines. 75.1907 Section 75.1907 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Diesel-Powered Equipment § 75.1907 Diesel-powered equipment intended for use in underground coal mines. (a) As of...
30 CFR 75.1907 - Diesel-powered equipment intended for use in underground coal mines.
Code of Federal Regulations, 2012 CFR
2012-07-01
... underground coal mines. 75.1907 Section 75.1907 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Diesel-Powered Equipment § 75.1907 Diesel-powered equipment intended for use in underground coal mines. (a) As of...
30 CFR 75.1907 - Diesel-powered equipment intended for use in underground coal mines.
Code of Federal Regulations, 2014 CFR
2014-07-01
... underground coal mines. 75.1907 Section 75.1907 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Diesel-Powered Equipment § 75.1907 Diesel-powered equipment intended for use in underground coal mines. (a) As of...
30 CFR 75.1907 - Diesel-powered equipment intended for use in underground coal mines.
Code of Federal Regulations, 2010 CFR
2010-07-01
... underground coal mines. 75.1907 Section 75.1907 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Diesel-Powered Equipment § 75.1907 Diesel-powered equipment intended for use in underground coal mines. (a) As of...
78 FR 73471 - Refuge Alternatives for Underground Coal Mines
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-06
... Refuge Alternatives for Underground Coal Mines AGENCY: Mine Safety and Health Administration, Labor... Agency's Request for Information (RFI) on Refuge Alternatives for Underground Coal Mines. This extension...), MSHA published a Request for Information on Refuge Alternatives for Underground Coal Mines. The RFI...
78 FR 58264 - Refuge Alternatives for Underground Coal Mines
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-23
... Refuge Alternatives for Underground Coal Mines AGENCY: Mine Safety and Health Administration, Labor... Agency's Request for Information (RFI) on Refuge Alternatives for Underground Coal Mines. This extension... Alternatives for Underground Coal Mines. The RFI comment period had been scheduled to close on October 7, 2013...
76 FR 70075 - Proximity Detection Systems for Continuous Mining Machines in Underground Coal Mines
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-10
... Detection Systems for Continuous Mining Machines in Underground Coal Mines AGENCY: Mine Safety and Health... proposed rule addressing Proximity Detection Systems for Continuous Mining Machines in Underground Coal... Detection Systems for Continuous Mining Machines in Underground Coal Mines. MSHA conducted hearings on...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-31
... Extension of Existing Information Collection; Refuge Alternatives for Underground Coal Mines AGENCY: Mine... Underground Coal Mines DATES: Submit comments on or before April 2, 2012. ADDRESSES: Comments must be.... Title: Refuge Alternatives for Underground Coal Mines. OMB Number: 1219-0146. Affected Public: Business...
76 FR 35801 - Examinations of Work Areas in Underground Coal Mines and Pattern of Violations
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-20
..., 1219-AB73 Examinations of Work Areas in Underground Coal Mines and Pattern of Violations AGENCY: Mine... public hearings on the Agency's proposed rules for Examinations of Work Areas in Underground Coal Mines... Underground Coal Mines' submissions, and with ``RIN 1219-AB73'' for Pattern of Violations' submissions...
78 FR 48591 - Refuge Alternatives for Underground Coal Mines
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-08
... Administration 30 CFR Parts 7 and 75 Refuge Alternatives for Underground Coal Mines; Proposed Rules #0;#0;Federal... Underground Coal Mines AGENCY: Mine Safety and Health Administration, Labor. ACTION: Limited reopening of the... for miners to deploy and use refuge alternatives in underground coal mines. The U.S. Court of Appeals...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-01
... Examinations of Work Areas in Underground Coal Mines for Violations of Mandatory Health or Safety Standards... rule addressing Examinations of Work Areas in Underground Coal Mines for Violations of Mandatory Health..., and weekly examinations of underground coal mines. This extension gives commenters an additional 30...
76 FR 25277 - Examinations of Work Areas in Underground Coal Mines and Pattern of Violations
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-04
..., 1219-AB73 Examinations of Work Areas in Underground Coal Mines and Pattern of Violations AGENCY: Mine... four public hearings on the Agency's proposed rules for Examinations of Work Areas in Underground Coal... 1219-AB75'' for Examinations of Work Areas in Underground Coal Mines' submissions, and with ``RIN 1219...
Solid fossil-fuel recovery by electrical induction heating in situ - A proposal
NASA Astrophysics Data System (ADS)
Fisher, S.
1980-04-01
A technique, termed electrical induction heating, is proposed for in situ processes of energy production from solid fossil fuels, such as bitumen production from underground distillation of oil sand; oil by underground distillation of oil shale; petroleum from heavy oil by underground mobilization of heavy oil, from either residues of conventional liquid petroleum deposits or new deposits of viscous oil; methane and coal tar from lignite and coal deposits by underground distillation of coal; and generation of electricity by surface combustion of low calorific-value gas from underground coke gasification by combustion of the organic residue left from the underground distillation of coal by induction heating. A method of surface distillation of mined coking coal by induction heating to produce coke, methane, and coal tar is also proposed.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Opening of new underground coal mines, or reopening and reactivating of abandoned or deactivated coal mines, notification by the operator... LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75...
78 FR 68783 - Refuge Alternatives for Underground Coal Mines
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-15
... Alternatives for Underground Coal Mines AGENCY: Mine Safety and Health Administration, Labor. ACTION: Reopen... coal mines. The U.S. Court of Appeals for the District of Columbia Circuit remanded a training... for refuge alternatives in underground coal mines. On January 13, 2009, the United Mine Workers of...
43 CFR 20.402 - Interests in underground or surface coal mining operations.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 43 Public Lands: Interior 1 2012-10-01 2011-10-01 true Interests in underground or surface coal... Certain Employees of the Department § 20.402 Interests in underground or surface coal mining operations... coal mining operations means ownership or part ownership by an employee of lands, stocks, bonds...
43 CFR 20.402 - Interests in underground or surface coal mining operations.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 43 Public Lands: Interior 1 2011-10-01 2011-10-01 false Interests in underground or surface coal... Certain Employees of the Department § 20.402 Interests in underground or surface coal mining operations... coal mining operations means ownership or part ownership by an employee of lands, stocks, bonds...
43 CFR 20.402 - Interests in underground or surface coal mining operations.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 43 Public Lands: Interior 1 2010-10-01 2010-10-01 false Interests in underground or surface coal... Certain Employees of the Department § 20.402 Interests in underground or surface coal mining operations... coal mining operations means ownership or part ownership by an employee of lands, stocks, bonds...
Yang, Qianlong; Zhang, Zhenyu; Liu, Xiaoqian; Ma, Shuqi
2017-01-01
The deformation of underground gateroads tends to be asymmetric and complex. Traditional instrumentation fails to accurately and conveniently monitor the full cross-sectional deformation of underground gateroads. Here, a full cross-sectional laser scanner was developed, together with a visualization software package. The developed system used a polar coordinate measuring method and the full cross-sectional measurement was shown by 360° rotation of a laser sensor driven by an electrical motor. Later on, the potential impact of gateroad wall flatness, roughness, and geometrical profile, as well as coal dust environment on the performance of the developed laser scanner will be evaluated. The study shows that high-level flatness is favorable in the application of the developed full cross-sectional deformation monitoring system. For a smooth surface of gateroad, the sensor cannot receive reflected light when the incidence angle of laser beam is large, causing data loss. Conversely, the roughness surface shows its nature as the diffuse reflection light can be received by the sensor. With regards to coal dust in the measurement environment, fine particles of floating coal dust in the air can lead to the loss of measurement data to some extent, due to scattering of the laser beam. PMID:28590449
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
The goal of the U.S. Department of Energy Underground Coal Conversion (UCC) program is to develop the technology to produce clean fuels from coal deposits unsuitable for commercial exploitation by conventional mining techniques. The highest priority is to develop and demonstrate, in conjunction with industry, a commercially feasible process for underground gasification of low-rank coal in the 1985--1987 time period. The program will also attempt to develop cost-effective technologies to utilize steeply dipping seams and bituminous coal by UCC. Results of the program to date indicate that, while UCC is technically feasible, it still contains some process unknowns, environmental risks,more » and economic risks that require R and D. In order to contribute to the national energy goals, a strong DOE program which incorporates maximum industry involvement is planned. Major projects are described in some detail. Finally, a strong program of supporting activities will address specific problems identified in the field testing and will seek to advance UCC technology. In summary, the program's strategy is to remove the high-risk elements of UCC by resolving those technical, environmental, and economic uncertainties that remain, and to enable industry to assume responsibility for commercialization of the process.« less
Effects of coal mine subsidence in the Sheridan, Wyoming, area
Dunrud, C. Richard; Osterwald, Frank W.
1980-01-01
Analyses of the surface effects of past underground coal mining in the Sheridan, Wyoming, area suggest that underground mining of strippable coal deposits may damage the environment more over long periods of time than would modern surface mining, provided proper restoration procedures are followed after surface mining. Subsidence depressions and pits are a continuing hazard to the environment and to man's activities in the Sheridan, Wyo., area above abandoned underground mines in weak overburden less than about 60 m thick and where the overburden is less than about 10-15 times the thickness of coal mined. In addition, fires commonly start by spontaneous ignition when water and air enter the abandoned mine workings via subsidence cracks and pits. The fires can then spread to unmined coal as they create more cavities, more subsidence, and more cracks and pits through which air can circulate. In modern surface mining operations the total land surface underlain by minable coal is removed to expose the coal. The coal is removed, the overburden and topsoil are replaced, and the land is regraded and revegetated. The land, although disturbed, can be more easily restored and put back into use than can land underlain by abandoned underground mine workings in areas where the overburden is less than about 60 m thick or less than about 10-15 times the thickness of coal mined. The resource recovery of modern surface mining commonly is much greater than that of underground mining procedures. Although present-day underground mining technology is advanced as compared to that of 25-80 years ago, subsidence resulting from underground mining of thick coal beds beneath overburden less than about 60 m thick can still cause greater damage to surface drainage, ground water, and vegetation than can properly designed surface mining operations. This report discusses (11 the geology and surface and underground effects of former large-scale underground coal mining in a 50-km 2 area 5-20 km north of Sheridan, Wyo., (2) a ground and aerial reconnaissance study of a 5-km^2 coal mining area 8-10 km west of Sheridan, and (31 some environmental consequences and problems caused by coal mining.
78 FR 48593 - Refuge Alternatives for Underground Coal Mines
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-08
... conduct research and tests concerning the use of refuge chambers in underground coal mines, and to report... of Information MSHA will post all comments and information on the Internet without change, including... actions. NIOSH finalized its Research Report on Refuge Alternatives for Underground Coal Mines (NIOSH...
76 FR 63238 - Proximity Detection Systems for Continuous Mining Machines in Underground Coal Mines
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-12
... Detection Systems for Continuous Mining Machines in Underground Coal Mines AGENCY: Mine Safety and Health... Agency's proposed rule addressing Proximity Detection Systems for Continuous Mining Machines in... proposed rule for Proximity Detection Systems on Continuous Mining Machines in Underground Coal Mines. Due...
30 CFR 75.1712-10 - Underground sanitary facilities; maintenance.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Underground sanitary facilities; maintenance... LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1712-10 Underground sanitary facilities; maintenance. Sanitary toilets shall be regularly maintained in...
30 CFR 75.1712-10 - Underground sanitary facilities; maintenance.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Underground sanitary facilities; maintenance... LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1712-10 Underground sanitary facilities; maintenance. Sanitary toilets shall be regularly maintained in...
30 CFR 75.1712-10 - Underground sanitary facilities; maintenance.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Underground sanitary facilities; maintenance... LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1712-10 Underground sanitary facilities; maintenance. Sanitary toilets shall be regularly maintained in...
30 CFR 75.1712-10 - Underground sanitary facilities; maintenance.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Underground sanitary facilities; maintenance... LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1712-10 Underground sanitary facilities; maintenance. Sanitary toilets shall be regularly maintained in...
30 CFR 75.1712-10 - Underground sanitary facilities; maintenance.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Underground sanitary facilities; maintenance... LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1712-10 Underground sanitary facilities; maintenance. Sanitary toilets shall be regularly maintained in...
30 CFR 75.811 - High-voltage underground equipment; grounding.
Code of Federal Regulations, 2010 CFR
2010-07-01
...-voltage equipment supplying power to such equipment receiving power from resistance grounded systems shall... 30 Mineral Resources 1 2010-07-01 2010-07-01 false High-voltage underground equipment; grounding... COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Underground High-Voltage...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-26
... Examinations of Work Areas in Underground Coal Mines for Violations of Mandatory Health or Safety Standards... effectiveness of information collection requirements contained in the final rule on Examinations of Work Areas... requirements in MSHA's final rule on Examinations of Work Areas in Underground Coal Mines for Violations of...
30 CFR 784.25 - Return of coal processing waste to abandoned underground workings.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 3 2010-07-01 2010-07-01 false Return of coal processing waste to abandoned... ENFORCEMENT, DEPARTMENT OF THE INTERIOR SURFACE COAL MINING AND RECLAMATION OPERATIONS PERMITS AND COAL... RECLAMATION AND OPERATION PLAN § 784.25 Return of coal processing waste to abandoned underground workings. (a...
30 CFR 784.25 - Return of coal processing waste to abandoned underground workings.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 3 2014-07-01 2014-07-01 false Return of coal processing waste to abandoned... ENFORCEMENT, DEPARTMENT OF THE INTERIOR SURFACE COAL MINING AND RECLAMATION OPERATIONS PERMITS AND COAL... RECLAMATION AND OPERATION PLAN § 784.25 Return of coal processing waste to abandoned underground workings. (a...
30 CFR 49.20 - Requirements for all coal mines.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Requirements for all coal mines. 49.20 Section... TRAINING MINE RESCUE TEAMS Mine Rescue Teams for Underground Coal Mines § 49.20 Requirements for all coal mines. (a) The operator of each underground coal mine shall make available two certified mine rescue...
30 CFR 49.20 - Requirements for all coal mines.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Requirements for all coal mines. 49.20 Section... TRAINING MINE RESCUE TEAMS Mine Rescue Teams for Underground Coal Mines § 49.20 Requirements for all coal mines. (a) The operator of each underground coal mine shall make available two certified mine rescue...
30 CFR 784.25 - Return of coal processing waste to abandoned underground workings.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 3 2013-07-01 2013-07-01 false Return of coal processing waste to abandoned... ENFORCEMENT, DEPARTMENT OF THE INTERIOR SURFACE COAL MINING AND RECLAMATION OPERATIONS PERMITS AND COAL... RECLAMATION AND OPERATION PLAN § 784.25 Return of coal processing waste to abandoned underground workings. (a...
30 CFR 49.20 - Requirements for all coal mines.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Requirements for all coal mines. 49.20 Section... TRAINING MINE RESCUE TEAMS Mine Rescue Teams for Underground Coal Mines § 49.20 Requirements for all coal mines. (a) The operator of each underground coal mine shall make available two certified mine rescue...
30 CFR 49.20 - Requirements for all coal mines.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Requirements for all coal mines. 49.20 Section... TRAINING MINE RESCUE TEAMS Mine Rescue Teams for Underground Coal Mines § 49.20 Requirements for all coal mines. (a) The operator of each underground coal mine shall make available two certified mine rescue...
30 CFR 49.20 - Requirements for all coal mines.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Requirements for all coal mines. 49.20 Section... TRAINING MINE RESCUE TEAMS Mine Rescue Teams for Underground Coal Mines § 49.20 Requirements for all coal mines. (a) The operator of each underground coal mine shall make available two certified mine rescue...
McAdoo, Mitchell A.; Kozar, Mark D.
2017-11-14
This report describes a compilation of existing water-quality data associated with groundwater resources originating from abandoned underground coal mines in West Virginia. Data were compiled from multiple sources for the purpose of understanding the suitability of groundwater from abandoned underground coal mines for public supply, industrial, agricultural, and other uses. This compilation includes data collected for multiple individual studies conducted from July 13, 1973 through September 7, 2016. Analytical methods varied by the time period of data collection and requirements of the independent studies.This project identified 770 water-quality samples from 294 sites that could be attributed to abandoned underground coal mine aquifers originating from multiple coal seams in West Virginia.
30 CFR 75.1902 - Underground diesel fuel storage-general requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Underground diesel fuel storage-general... LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Diesel-Powered Equipment § 75.1902 Underground diesel fuel storage—general requirements. (a) All diesel fuel must be stored...
30 CFR 75.1902 - Underground diesel fuel storage-general requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Underground diesel fuel storage-general... LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Diesel-Powered Equipment § 75.1902 Underground diesel fuel storage—general requirements. (a) All diesel fuel must be stored...
Zhang, Yu; Yang, Wei; Han, Dongsheng; Kim, Young-Il
2014-01-01
Environment monitoring is important for the safety of underground coal mine production, and it is also an important application of Wireless Sensor Networks (WSNs). We put forward an integrated environment monitoring system for underground coal mine, which uses the existing Cable Monitoring System (CMS) as the main body and the WSN with multi-parameter monitoring as the supplementary technique. As CMS techniques are mature, this paper mainly focuses on the WSN and the interconnection between the WSN and the CMS. In order to implement the WSN for underground coal mines, two work modes are designed: periodic inspection and interrupt service; the relevant supporting technologies, such as routing mechanism, collision avoidance, data aggregation, interconnection with the CMS, etc., are proposed and analyzed. As WSN nodes are limited in energy supply, calculation and processing power, an integrated network management scheme is designed in four aspects, i.e., topology management, location management, energy management and fault management. Experiments were carried out both in a laboratory and in a real underground coal mine. The test results indicate that the proposed integrated environment monitoring system for underground coal mines is feasible and all designs performed well as expected. PMID:25051037
Zhang, Yu; Yang, Wei; Han, Dongsheng; Kim, Young-Il
2014-07-21
Environment monitoring is important for the safety of underground coal mine production, and it is also an important application of Wireless Sensor Networks (WSNs). We put forward an integrated environment monitoring system for underground coal mine, which uses the existing Cable Monitoring System (CMS) as the main body and the WSN with multi-parameter monitoring as the supplementary technique. As CMS techniques are mature, this paper mainly focuses on the WSN and the interconnection between the WSN and the CMS. In order to implement the WSN for underground coal mines, two work modes are designed: periodic inspection and interrupt service; the relevant supporting technologies, such as routing mechanism, collision avoidance, data aggregation, interconnection with the CMS, etc., are proposed and analyzed. As WSN nodes are limited in energy supply, calculation and processing power, an integrated network management scheme is designed in four aspects, i.e., topology management, location management, energy management and fault management. Experiments were carried out both in a laboratory and in a real underground coal mine. The test results indicate that the proposed integrated environment monitoring system for underground coal mines is feasible and all designs performed well as expected.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 3 2010-07-01 2010-07-01 false Bonding requirements for underground coal mines and long-term coal-related surface facilities and structures. 800.17 Section 800.17 Mineral Resources... REQUIREMENTS FOR SURFACE COAL MINING AND RECLAMATION OPERATIONS BOND AND INSURANCE REQUIREMENTS FOR SURFACE...
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 3 2012-07-01 2012-07-01 false Bonding requirements for underground coal mines and long-term coal-related surface facilities and structures. 800.17 Section 800.17 Mineral Resources... REQUIREMENTS FOR SURFACE COAL MINING AND RECLAMATION OPERATIONS BOND AND INSURANCE REQUIREMENTS FOR SURFACE...
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 3 2013-07-01 2013-07-01 false Bonding requirements for underground coal mines and long-term coal-related surface facilities and structures. 800.17 Section 800.17 Mineral Resources... REQUIREMENTS FOR SURFACE COAL MINING AND RECLAMATION OPERATIONS BOND AND INSURANCE REQUIREMENTS FOR SURFACE...
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 3 2014-07-01 2014-07-01 false Bonding requirements for underground coal mines and long-term coal-related surface facilities and structures. 800.17 Section 800.17 Mineral Resources... REQUIREMENTS FOR SURFACE COAL MINING AND RECLAMATION OPERATIONS BOND AND INSURANCE REQUIREMENTS FOR SURFACE...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 3 2011-07-01 2011-07-01 false Bonding requirements for underground coal mines and long-term coal-related surface facilities and structures. 800.17 Section 800.17 Mineral Resources... REQUIREMENTS FOR SURFACE COAL MINING AND RECLAMATION OPERATIONS BOND AND INSURANCE REQUIREMENTS FOR SURFACE...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-23
... combustible coal dust and explosive methane gas are present. This information collection request (ICR) was... underground coal mine where combustible coal dust and explosive methane gas are present. This information...
Methane Content Estimation in DuongHuy Coal Mine
NASA Astrophysics Data System (ADS)
Nguyen, Van Thinh; Mijał, Waldemar; Dang, Vu Chi; Nguyen, Thi Tuyet Mai
2018-03-01
Methane hazard has always been considered for underground coal mining as it can lead to methane explosion. In Quang Ninh province, several coal mines such as Mạo Khe coal mine, Khe Cham coal mine, especially Duong Huy mine that have high methane content. Experimental data to examine contents of methane bearing coal seams at different depths are not similar in Duong coal mine. In order to ensure safety, this report has been undertaken to determine a pattern of changing methane contents of coal seams at different exploitation depths in Duong Huy underground coal mine.
30 CFR 72.500 - Emission limits for permissible diesel-powered equipment.
Code of Federal Regulations, 2012 CFR
2012-07-01
... underground coal mine after May 21, 2001 must emit no more than 2.5 grams per hour of diesel particulate... underground area of an underground coal mine must emit no more than 2.5 grams per hour of diesel particulate...
30 CFR 72.500 - Emission limits for permissible diesel-powered equipment.
Code of Federal Regulations, 2010 CFR
2010-07-01
... underground coal mine after May 21, 2001 must emit no more than 2.5 grams per hour of diesel particulate... underground area of an underground coal mine must emit no more than 2.5 grams per hour of diesel particulate...
30 CFR 72.500 - Emission limits for permissible diesel-powered equipment.
Code of Federal Regulations, 2011 CFR
2011-07-01
... underground coal mine after May 21, 2001 must emit no more than 2.5 grams per hour of diesel particulate... underground area of an underground coal mine must emit no more than 2.5 grams per hour of diesel particulate...
30 CFR 72.500 - Emission limits for permissible diesel-powered equipment.
Code of Federal Regulations, 2013 CFR
2013-07-01
... underground coal mine after May 21, 2001 must emit no more than 2.5 grams per hour of diesel particulate... underground area of an underground coal mine must emit no more than 2.5 grams per hour of diesel particulate...
30 CFR 784.10 - Information collection.
Code of Federal Regulations, 2010 CFR
2010-07-01
... COAL MINING AND RECLAMATION OPERATIONS PERMITS AND COAL EXPLORATION SYSTEMS UNDER REGULATORY PROGRAMS UNDERGROUND MINING PERMIT APPLICATIONS-MINIMUM REQUIREMENTS FOR RECLAMATION AND OPERATION PLAN § 784.10... requires applicants for permits for underground coal mines to prepare and submit an operation and...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-27
... for OMB Review; Comment Request; Ground Control Plans for Surface Coal Mines and Surface Work Areas of Underground Coal Mines ACTION: Notice. SUMMARY: The Department of Labor (DOL) is submitting the Mine Safety... Control Plans for Surface Coal Mines and Surface Work Areas of Underground Coal Mines,'' to the Office of...
Effect of the 2.0 mg/m3 coal mine dust standard on underground environmental dust levels.
Parobeck
1975-08-01
The 1969 Federal Coal Mine Health and Safety Act established environmental dust standards for underground coal mines. The Act requires that the average concentration of respirable dust in the active workings of a mine be maintained at or below 3.0 mg/m3; and, that effective December 30, 1972, the 3.0 mg/m3 standard be reduced to 2.0 mg/m3. This paper discusses the current status of dust levels in our underground coal mines, the effect of the 2.0 mg/m3 standard on underground dust levels, and associates the current levels with specific operations and occupations. The comparison is made between current levels and those existing prior to December 30, 1972.
Fast and safe gas detection from underground coal fire by drone fly over.
Dunnington, Lucila; Nakagawa, Masami
2017-10-01
Underground coal fires start naturally or as a result of human activities. Besides burning away the important non-renewable energy resource and causing financial losses, burning coal seams emit carbon dioxide, carbon monoxide, sulfur oxide and methane, and is a leading cause of smog, acid rain, global warming, and air toxins. In the U.S. alone, the combined cost of coal-fire remediation projects that have been completed, budgeted, or projected by the U.S. Department of the Interior's Office of Surface Mining Remediation and Enforcement (OSM), exceeds $1 billion. It is estimated that these fires generate as much as 3% of the world's annual carbon dioxide emissions and consume as much as 5% of its minable coal. Considering the magnitude of environmental impact and economic loss caused by burning underground coal seams, we have developed a new, safe, reliable surface measurement of coal fire gases to assess the nature of underground coal fires. We use a drone mounted with gas sensors. Drone collected gas concentration data provides a safe alternative for evaluating the rank of a burning coal seam. In this study, a new method of determining coal rank by gas ratios is developed. Coal rank is valuable for defining parameters of a coal seam such as burn temperature, burn rate, and volume of burning seam. Copyright © 2017 Elsevier Ltd. All rights reserved.
2015-01-01
Ground control research in underground coal mines has been ongoing for over 50 years. One of the most problematic issues in underground coal mines is roof failures associated with weak shale. This paper will present a historical narrative on the research the National Institute for Occupational Safety and Health has conducted in relation to rock mechanics and shale. This paper begins by first discussing how shale is classified in relation to coal mining. Characterizing and planning for weak roof sequences is an important step in developing an engineering solution to prevent roof failures. Next, the failure mechanics associated with the weak characteristics of shale will be discussed. Understanding these failure mechanics also aids in applying the correct engineering solutions. The various solutions that have been implemented in the underground coal mining industry to control the different modes of failure will be summarized. Finally, a discussion on current and future research relating to rock mechanics and shale is presented. The overall goal of the paper is to share the collective ground control experience of controlling roof structures dominated by shale rock in underground coal mining. PMID:26549926
Murphy, M M
2016-02-01
Ground control research in underground coal mines has been ongoing for over 50 years. One of the most problematic issues in underground coal mines is roof failures associated with weak shale. This paper will present a historical narrative on the research the National Institute for Occupational Safety and Health has conducted in relation to rock mechanics and shale. This paper begins by first discussing how shale is classified in relation to coal mining. Characterizing and planning for weak roof sequences is an important step in developing an engineering solution to prevent roof failures. Next, the failure mechanics associated with the weak characteristics of shale will be discussed. Understanding these failure mechanics also aids in applying the correct engineering solutions. The various solutions that have been implemented in the underground coal mining industry to control the different modes of failure will be summarized. Finally, a discussion on current and future research relating to rock mechanics and shale is presented. The overall goal of the paper is to share the collective ground control experience of controlling roof structures dominated by shale rock in underground coal mining.
NASA Astrophysics Data System (ADS)
Murphy, M. M.
2016-02-01
Ground control research in underground coal mines has been ongoing for over 50 years. One of the most problematic issues in underground coal mines is roof failures associated with weak shale. This paper will present a historical narrative on the research the National Institute for Occupational Safety and Health has conducted in relation to rock mechanics and shale. This paper begins by first discussing how shale is classified in relation to coal mining. Characterizing and planning for weak roof sequences is an important step in developing an engineering solution to prevent roof failures. Next, the failure mechanics associated with the weak characteristics of shale will be discussed. Understanding these failure mechanics also aids in applying the correct engineering solutions. The various solutions that have been implemented in the underground coal mining industry to control the different modes of failure will be summarized. Finally, a discussion on current and future research relating to rock mechanics and shale is presented. The overall goal of the paper is to share the collective ground control experience of controlling roof structures dominated by shale rock in underground coal mining.
GENERAL EXTERIOR VIEW, LOOKING NORTHEAST, OF THE SURFACE PLANT WITH ...
GENERAL EXTERIOR VIEW, LOOKING NORTHEAST, OF THE SURFACE PLANT WITH CONVEYORS. JIM WALTER RESOURCES INC. MINING DIVISION OPERATES FOUR UNDERGROUND COAL MINES IN THE BLUE CREEK COAL FIELD OF BIRMINGHAM DISTRICT, THREE IN TUSCALOOSA COUNTY AND ONE IN JEFFERSON COUNTY. TOTAL ANNUAL PRODUCTION IS 8,000,000 TONS. AT 2,300 DEEP, JIM WALTER'S BROOKWOOD MINES ARE THE DEEPEST UNDERGROUND COAL MINES IN NORTH AMERICA. THEY PRODUCE A HIGH-GRADE MEDIUM VOLATILE LOW SULPHUR METALLURGICAL COAL. THE BROOKWOOD NO. 5 MINE (PICTURED IN THIS PHOTOGRAPH) EMPLOYS THE LONGWALL MINING TECHNIQUES WITH BELTS CONVEYING COAL FROM UNDERGROUND OPERATIONS TO THE SURFACE. - JIm Walter Resources, Incorporated, Brookwood No. 5 Mine, 12972 Lock 17 Road, Brookwood, Tuscaloosa County, AL
30 CFR 72.510 - Miner health training.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Miner health training. 72.510 Section 72.510 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH HEALTH STANDARDS FOR COAL MINES Diesel Particulate Matter-Underground Areas of Underground Coal Mines...
30 CFR 72.510 - Miner health training.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Miner health training. 72.510 Section 72.510 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH HEALTH STANDARDS FOR COAL MINES Diesel Particulate Matter-Underground Areas of Underground Coal Mines...
30 CFR 72.510 - Miner health training.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Miner health training. 72.510 Section 72.510 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH HEALTH STANDARDS FOR COAL MINES Diesel Particulate Matter-Underground Areas of Underground Coal Mines...
30 CFR 72.510 - Miner health training.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Miner health training. 72.510 Section 72.510 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH HEALTH STANDARDS FOR COAL MINES Diesel Particulate Matter-Underground Areas of Underground Coal Mines...
30 CFR 72.510 - Miner health training.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Miner health training. 72.510 Section 72.510 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH HEALTH STANDARDS FOR COAL MINES Diesel Particulate Matter-Underground Areas of Underground Coal Mines...
Code of Federal Regulations, 2010 CFR
2010-07-01
... SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES General § 75.1 Scope. This part 75 sets forth safety standards compliance with which is mandatory in each underground coal mine subject to the Federal Mine Safety and Health Act...
Code of Federal Regulations, 2013 CFR
2013-07-01
... SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES General § 75.1 Scope. This part 75 sets forth safety standards compliance with which is mandatory in each underground coal mine subject to the Federal Mine Safety and Health Act...
Code of Federal Regulations, 2012 CFR
2012-07-01
... SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES General § 75.1 Scope. This part 75 sets forth safety standards compliance with which is mandatory in each underground coal mine subject to the Federal Mine Safety and Health Act...
Code of Federal Regulations, 2011 CFR
2011-07-01
... SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES General § 75.1 Scope. This part 75 sets forth safety standards compliance with which is mandatory in each underground coal mine subject to the Federal Mine Safety and Health Act...
Code of Federal Regulations, 2014 CFR
2014-07-01
... SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES General § 75.1 Scope. This part 75 sets forth safety standards compliance with which is mandatory in each underground coal mine subject to the Federal Mine Safety and Health Act...
[Effect of underground work on cardiovascular system in coal miners].
Lai, Zhiwei; Wang, Xiaoye; Tan, Hongzhuan; Huang, Yaoyu; Lu, Changcheng
2015-10-01
To study the effect of underground work on cardiovascular system health in coal miners. Male coal miners, who received electrocardiographic examinations between June, 2013 and August, 2014 in Hunan Prevention and Treatment Institute for Occupational Diseases to exclude pneumoconiosis, were enrolled for this study (n=3 134). Miners with 2 years or more underground work experience were selected as the exposed group (n=2 370), while miners without underground work experience were selected as the control group (n=764). The prevalence of electrocardiographic abnormalities and the influential factors were compared between the 2 groups. The prevalences of electrocardiographic abnormalities, hypertension, heart rate abnormalities and cardiovascular system abnormalities in the exposed group vs the control group were 37.6% vs 25.4%, 20.5% vs 13.4%, 5.7% vs 6.0%, 49.8% vs 35.2%, respectively. The cardiovascular system abnormalities were correlated with the underground work (OR=3.128, 95% CI: 1.969-4.970), the underground work experience (OR=1.205, 95% CI: 1.070-1.358) and the type of works (mining worker OR=1.820, 95% CI: 1.527-2.169; auxiliary worker OR=1.937, 95% CI: 1.511-2.482; other worker OR=3.291, 95%CI: 2.120-5.109). Underground work may increase the prevalence of cardiovascular system abnormalities for coal miners. The longer the coal miners work in underground, the higher the risk of the cardiovascular system abnormalities they are.
Competitiveness and potentials of UCG-CCS on the European energy market
NASA Astrophysics Data System (ADS)
Kempka, T.; Nakaten, N.; Schlüter, R.; Fernandez-Steeger, T.; Azzam, R.
2009-04-01
The world-wide coal reserves can satisfy the world's primary energy demand for several hundred years. However, deep coal deposits with seams of low thickness and structural complexity do currently not allow an economic exploitation of many deposits. Here, underground coal gasification (UCG) can offer an economical approach for coal extraction. The intended overall process relies on coal deposit exploitation using directed drillings located at the coal seam base and the subsequent in situ coal conversion into a synthesis gas. The resulting synthesis gas is used for electricity generation in a combined cycle plant at the surface. A reduction of the CO2 emissions resulting from the combined process is realized by subsequent CO2 capture and its injection into the previously gasified coal seams. The scope of the present study was the investigation of UCG-CCS competitiveness on the European energy market and the determination of the impacting factors. For that purpose, a modular model for calculation of UCG-CCS electricity generation costs was implemented and adapted to the most relevant process parameters. Furthermore, the range of energy supply coverage was estimated based on different German energy generation scenarios.
Levine, Betty A; Ingeholm, Mary Lou; Prior, Fred; Mun, Seong K; Freedman, Matthew; Weissman, David; Attfield, Michael; Wolfe, Anita; Petsonk, Edward
2009-01-01
To protect the health of active U.S. underground coal miners, the National Institute for Occupational Safety and Health (NIOSH) has a mandate to carry out surveillance for coal workers' pneumoconiosis, commonly known as Black Lung (PHS 2001). This is accomplished by reviewing chest x-ray films obtained from miners at approximately 5-year intervals in approved x-ray acquisition facilities around the country. Currently, digital chest images are not accepted. Because most chest x-rays are now obtained in digital format, NIOSH is redesigning the surveillance program to accept and manage digital x-rays. This paper highlights the functional and security requirements for a digital image management system for a surveillance program. It also identifies the operational differences between a digital imaging surveillance network and a clinical Picture Archiving Communication Systems (PACS) or teleradiology system.
30 CFR 75.1106-3 - Storage of liquefied and nonliquefied compressed gas cylinders; requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES...; requirements. (a) Liquefied and nonliquefied compressed gas cylinders stored in an underground coal mine shall... falling material, contact with power lines and energized electrical equipment, heat from welding, cutting...
NASA Astrophysics Data System (ADS)
Popov, Valeriy; Filatov, Yuriy; Lee, Hee; Golik, Anatoliy
2017-11-01
The paper discusses the problem of the underground mining safety control. The long-term air intake to coal accumulations is reviewed as one of the reasons of endogenous fires during mining. The methods of combating air leaks (inflows) in order to prevent endogenous fires are analyzed. The calculations showing the discrepancy between the design calculations for the mine ventilation, disregarding a number of mining-andgeological and mining-engineering factors, and the actual conditions of mining are given. It is proved that the conversion of operating mines to combined (pressure and exhaust) ventilation system in order to reduce the endogenous fire hazard of underground mining is unreasonable due to impossibility of providing an optimal distribution of aerodynamic pressure in mines. The conversion does not exclude the entry of air into potentially hazardous zones of endogenous fires. The essence of the combined application of positive and negative control methods for the distribution of air pressure is revealed. It consists of air doors installation in easily ventilated airways and installation of pressure equalization chambers equipped with auxiliary fans near the stoppings, working sections and in parallel airways.The effectiveness of the combined application of negative and positive control methods for the air pressure distribution in order to reduce endogenous fire hazard of mining operations is proved.
A study of leakage rates through mine seals in underground coal mines
Schatzel, Steven J.; Krog, Robert B.; Mazzella, Andrew; Hollerich, Cynthia; Rubinstein, Elaine
2015-01-01
The National Institute for Occupational Safety and Health conducted a study on leakage rates through underground coal mine seals. Leakage rates of coal bed gas into active workings have not been well established. New seal construction standards have exacerbated the knowledge gap in our understanding of how well these seals isolate active workings near a seal line. At a western US underground coal mine, we determined seal leakage rates ranged from about 0 to 0.036 m3/s for seven 340 kPa seals. The seal leakage rate varied in essentially a linear manner with variations in head pressure at the mine seals. PMID:26322119
Prevalence and Associated Factors of Depressive Symptoms among Chinese Underground Coal Miners
Liu, Li; Wang, Lie; Chen, Jie
2014-01-01
Although underground coal miners are quite susceptible to depressive symptoms due to a highly risky and stressful working environment, few studies have focused on this issue. The purpose of the study was to evaluate the prevalence of depressive symptoms and to explore its associated factors in this population. A cross-sectional survey was conducted in a coal-mining population in northeast China. A set of self-administered questionnaires was distributed to 2500 underground coal miners (1,936 effective respondents). Depressive symptoms, effort-reward imbalance (ERI), overcommitment (OC), perceived physical environment (PPE), work-family conflict (WFC), and some demographic and working characteristics were measured anonymously. The prevalence of depressive symptoms was 62.8%, and the mean level was 20.00 (9.99). Hierarchical linear regression showed that marital status, education, monthly income, and weekly working time were significantly associated with depressive symptoms. A high level of depressive symptoms was significantly associated with high ERI, PPE, WFC, and OC. Accordingly, most Chinese underground coal miners probably have depressive symptoms that are mainly predicted by some occupational psychosocial factors. Efforts should be made to develop strategies to reduce ERI and OC, improve physical working environment, and care for workers' family well-being, thereby mitigating the risk of depression among Chinese underground coal miners. PMID:24707503
Dobson, Jessica A; Riddiford-Harland, Diane L; Bell, Alison F; Steele, Julie R
2018-04-01
Mining work boots provide an interface between the foot and the ground, protecting and supporting miners' feet during lengthy coal mining shifts. Although underground coal miners report the fit of their work boots as reasonable to good, they frequently rate their boots as uncomfortable, suggesting that there is a mismatch between the shape of their feet and their boots. This study aimed to identify whether dimensions derived from the three-dimensional scans of 208 underground coal miners' feet (age 38.3 ± 9.8 years) differed from the internal dimensions of their work boots. The results revealed underground coal miners wore boots that were substantially longer than their feet, possibly because boots available in their correct length were too narrow. It is recommended boot manufacturers reassess the algorithms used to create boot lasts, focusing on adjusting boot circumference at the instep and heel relative to increases in foot length. Practitioner Summary: Fit and comfort ratings suggest a mismatch between the shape of underground coal miners' feet and their boots exists. This study examined whether three-dimensional scans of 208 miners' feet differed from their boot internal dimensions. Miners wore boots substantially longer than their feet, possibly due to inadequate width.
Prevalence and associated factors of depressive symptoms among Chinese underground coal miners.
Liu, Li; Wang, Lie; Chen, Jie
2014-01-01
Although underground coal miners are quite susceptible to depressive symptoms due to a highly risky and stressful working environment, few studies have focused on this issue. The purpose of the study was to evaluate the prevalence of depressive symptoms and to explore its associated factors in this population. A cross-sectional survey was conducted in a coal-mining population in northeast China. A set of self-administered questionnaires was distributed to 2500 underground coal miners (1,936 effective respondents). Depressive symptoms, effort-reward imbalance (ERI), overcommitment (OC), perceived physical environment (PPE), work-family conflict (WFC), and some demographic and working characteristics were measured anonymously. The prevalence of depressive symptoms was 62.8%, and the mean level was 20.00 (9.99). Hierarchical linear regression showed that marital status, education, monthly income, and weekly working time were significantly associated with depressive symptoms. A high level of depressive symptoms was significantly associated with high ERI, PPE, WFC, and OC. Accordingly, most Chinese underground coal miners probably have depressive symptoms that are mainly predicted by some occupational psychosocial factors. Efforts should be made to develop strategies to reduce ERI and OC, improve physical working environment, and care for workers' family well-being, thereby mitigating the risk of depression among Chinese underground coal miners.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-30
... Coal Mines ACTION: Notice. SUMMARY: The Department of Labor (DOL) is submitting the Mine Safety and... Continuous Mining Machines Standards for Underground Coal Mines,'' to the Office of Management and Budget... continuous mining machines (HVCMM) in underground coal mines by requiring records of testing, examination and...
30 CFR 77.403-1 - Mobile equipment; rollover protective structures (ROPS).
Code of Federal Regulations, 2010 CFR
2010-07-01
... WORK AREAS OF UNDERGROUND COAL MINES Safeguards for Mechanical Equipment § 77.403-1 Mobile equipment... surface coal mines or the surface work areas of underground coal mines shall be provided with rollover... complying with paragraph (d) (1) (iii) (A) of this section. Stresses shall not exceed the ultimate strength...
30 CFR 77.403-1 - Mobile equipment; rollover protective structures (ROPS).
Code of Federal Regulations, 2011 CFR
2011-07-01
... WORK AREAS OF UNDERGROUND COAL MINES Safeguards for Mechanical Equipment § 77.403-1 Mobile equipment... surface coal mines or the surface work areas of underground coal mines shall be provided with rollover... complying with paragraph (d) (1) (iii) (A) of this section. Stresses shall not exceed the ultimate strength...
NASA Technical Reports Server (NTRS)
Goldsmith, M.; Lavin, M. L.
1980-01-01
Underground mining systems suitable for coal seams expoitable in the year 2000 are examined with particular relevance to the resources of Central Appalachia. Requirements for such systems may be summarized as follows: (1) production cost; (2)miner safety; (3) miner health; (4) environmental impact; and (5) coal conservation. No significant trade offs between production cost and other performance indices were found.
Research of Characteristics of the Low Voltage Power Line in Underground Coal Mine
NASA Astrophysics Data System (ADS)
Wei, Shaoliang; Qin, Shiqun; Gao, Wenchang; Cheng, Fengyu; Cao, Zhongyue
The power line communications (PLCs) can count on existing electrical connections reaching each corner in the locations where such applications are required, so signal transmission over power lines is nowadays gaining more and more interest for applications like internet. The research of characteristics of the low voltage power line is the fundamental and importance task. This work presents a device to test the characteristics of the low voltage power line. The low voltage power line channel characteristics overground and the channel characteristics underground were tested in using this device. Experiments show that, the characteristics are different between the PLCs channel underground coal mine and the PLC channel overground. Different technology should be adopted to structure the PLCs channel model underground coal mine and transmit high speed digital signal. But how to use the technology better to the high-speed digital communication under coal mine is worth of further studying.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Young, B.C.; Schmit, C.R.
The report, conducted by Energy and Environmental Research Center, was funded by the US Trade and Development Agency. The objective of this report was to determine the technical, environmental and economic feasibility of developing, demonstrating, and commercializing underground coal gasification (UCG) at the Krabi coal mine site in Southern Thailand. This is Volume 1, the Progress Report for the period December 1, 1995, through December 31, 1995.
30 CFR 75.1901 - Diesel fuel requirements.
Code of Federal Regulations, 2014 CFR
2014-07-01
....1901 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Diesel-Powered Equipment § 75.1901 Diesel fuel... fuel purchased for use in diesel-powered equipment underground meets these requirements. (b) Flammable...
30 CFR 75.1901 - Diesel fuel requirements.
Code of Federal Regulations, 2013 CFR
2013-07-01
....1901 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Diesel-Powered Equipment § 75.1901 Diesel fuel... fuel purchased for use in diesel-powered equipment underground meets these requirements. (b) Flammable...
A Fiber Bragg Grating-Based Monitoring System for Roof Safety Control in Underground Coal Mining
Zhao, Yiming; Zhang, Nong; Si, Guangyao
2016-01-01
Monitoring of roof activity is a primary measure adopted in the prevention of roof collapse accidents and functions to optimize and support the design of roadways in underground coalmines. However, traditional monitoring measures, such as using mechanical extensometers or electronic gauges, either require arduous underground labor or cannot function properly in the harsh underground environment. Therefore, in this paper, in order to break through this technological barrier, a novel monitoring system for roof safety control in underground coal mining, using fiber Bragg grating (FBG) material as a perceived element and transmission medium, has been developed. Compared with traditional monitoring equipment, the developed, novel monitoring system has the advantages of providing accurate, reliable, and continuous online monitoring of roof activities in underground coal mining. This is expected to further enable the prevention of catastrophic roof collapse accidents. The system has been successfully implemented at a deep hazardous roadway in Zhuji Coal Mine, China. Monitoring results from the study site have demonstrated the advantages of FBG-based sensors over traditional monitoring approaches. The dynamic impacts of progressive face advance on roof displacement and stress have been accurately captured by the novel roadway roof activity and safety monitoring system, which provided essential references for roadway support and design of the mine. PMID:27775657
Thin seam miner/trench mining concepts for Illinois Basin surface coal mines
DOE Office of Scientific and Technical Information (OSTI.GOV)
Caudle, R.D.; Lall, V.
1985-07-01
A hybrid surface/underground mining concept, trench-auger mining is an attempt to increase the depth to which coal seams can be surface mined economically by reducing the amount of overburden which must be removed and reclaimed. In this concept the coal seam is first exposed by digging a series of parallel trenches 400 to 1200 ft apart with conventional surface mining equipment. After surface mining the coal from the bottom of the trench, the coal under the surface between the trenches would be extracted with extended-depth augers, operating from the bottoms of the trenches. The RSV Mining Equipment Co. of Hollandmore » has developed a Thin Seam Miner (TSM). The TSM is essentially a remotely controlled, continuous underground mining machine. The hydraulically driven drum cutter head and coal handling auger flights can be operated from a distance outside the underground mine workings. The purpose of this study is to develop and evaluate Thin Seam Miner/Trench Mining (TSM/TM) concepts for use under conditions existing in the Illinois Coal Basin.« less
Lightweight monitoring and control system for coal mine safety using REST style.
Cheng, Bo; Cheng, Xin; Chen, Junliang
2015-01-01
The complex environment of a coal mine requires the underground environment, devices and miners to be constantly monitored to ensure safe coal production. However, existing coal mines do not meet these coverage requirements because blind spots occur when using a wired network. In this paper, we develop a Web-based, lightweight remote monitoring and control platform using a wireless sensor network (WSN) with the REST style to collect temperature, humidity and methane concentration data in a coal mine using sensor nodes. This platform also collects information on personnel positions inside the mine. We implement a RESTful application programming interface (API) that provides access to underground sensors and instruments through the Web such that underground coal mine physical devices can be easily interfaced to remote monitoring and control applications. We also implement three different scenarios for Web-based, lightweight remote monitoring and control of coal mine safety and measure and analyze the system performance. Finally, we present the conclusions from this study and discuss future work. Copyright © 2014 ISA. Published by Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ames, R.G.; Trent, R.B.
1984-08-01
A five-year prospective study of 1,394 United States underground coal miners was undertaken to study the effects of respiratory impairment on the rate of early retirement with disability (ERD). Using a logistic regression analysis, ERD was found to be related to reported persistent phlegm after adjustment was made for other respiratory symptoms, respiratory function measurements, cigarette smoking, and some demographic characteristics. No prediction of ERD occurred for spirometrically determined measures of respiratory function. The data thus give limited support to the hypothesis that early retirement with disability in underground coal miners can be predicted prospectively by measures of respiratory symptoms.
A Look into Miners' Health in Prevailing Ambience of Underground Coal Mine Environment
NASA Astrophysics Data System (ADS)
Dey, N. C.; Pal, S.
2012-04-01
Environmental factors such as noise, vibration, illumination, humidity, temperature and air velocity, etc. do play a major role on the health, comfort and efficient performance of underground coal miners at work. Ergonomics can help to promote health, efficiency and well being of miners and to make best use of their capabilities within the ambit of underground coal mine environment. Adequate work stretch and work-rest scheduling have to be determined for every category of miners from work physiology point of view so as to keep better health of the miners in general and to have their maximum efficiency at work in particular.
Talbott, Evelyn O; Sharma, Ravi K; Buchanich, Jeanine; Stacy, Shaina L
2015-04-01
Exposures associated with coal mining activities, including diesel fuel exhaust, products used in coal processing, and heavy metals and other forms of particulate matter, may impact the health of nearby residents. We investigated the relationships between county-level circulatory hospitalization rates (CHRs) in coal and non-coal-mining communities of West Virginia, coal production, coal employment, and sociodemographic factors. Direct age-adjusted CHRs were calculated using West Virginia hospitalizations from 2005 to 2009. Spatial regressions were conducted to explore associations between CHR and total, underground, and surface coal production. After adjustment, neither total, nor surface, nor underground coal production was significantly related to rate of hospitalization for circulatory disease. Our findings underscore the significant role sociodemographic and behavioral factors play in the health and well-being of coal mining communities.
30 CFR 75.343 - Underground shops.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Underground shops. 75.343 Section 75.343...-3 through § 75.1107-16, or be enclosed in a noncombustible structure or area. (b) Underground shops... MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Ventilation § 75.343 Underground shops. (a) Underground...
30 CFR 75.819 - Motor-starter enclosures; barriers and interlocks.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Motor-starter enclosures; barriers and interlocks. 75.819 Section 75.819 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Underground High...
30 CFR 75.806 - Connection of single-phase loads.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Connection of single-phase loads. 75.806 Section 75.806 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Underground High-Voltage Distribution...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Scope. 75.823 Section 75.823 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Underground High-Voltage Distribution High-Voltage Longwalls § 75.823 Scope...
Deep-coal potential in the Appalachian Coal Basin, USA: The Kentucky model
Haney, D.C.; Chesnut, D.R.
1997-01-01
The Eastern Kentucky Coal Field is located in the Appalachian Basin of the United States and occupies an area of approximately 15,000 square kilometers. The coal beds range from a few centimeters to several meters in thickness and consist of high-grade bituminous coal. Currently the amount of coal mined by surface methods exceeds underground extraction; however, there is a steady and gradual shift toward underground mining. In the future, as near-surface resources are depleted, this trend toward increased underground mining will continue. Knowledge about deeper coals is essential for future economic development of resources. Preliminary investigations indicate that coal-bearing strata with deep-mining potential exist in several parts of eastern Kentucky, especially along the Eastern Kentucky Syncline. Eastern Kentucky coals are Westphalian A through D; however, current production is from major beds of Westphalian A and B. Because coals that occur above drainage are more easily accessible and are generally of better quality, most of the current mining takes place in formations that are at or near the surface. In the future, however, due to environmental regulations and increased demands, it will be necessary to attempt to utilize deeper coals about which little is known. Future development of deep resources will require data from boreholes and high-resolution geophysical-logging techniques. There is also potential for coal-bed methane from the deeper coals which could be an important resource in the Appalachian Coal Basin where a natural gas distribution system already exists.
Resource targets for advanced underground coal extraction systems
NASA Technical Reports Server (NTRS)
Hoag, J. H.; Whipple, D. W.; Habib-Agahi, H.; Lavin, M. L.
1982-01-01
Resource targets appropriate for federal sponsorship of research and development of advanced underground coal mining systems are identified. A comprehensive examination of conventional and unconventional coals with particular attention to exceptionally thin and thick seams, steeply dipping beds, and multiple seam geometry was made. The results indicate that the resource of primary importance is flat lying bituminous coal of moderate thickness, under moderate cover, and located within the lower 48 states. Resources of secondary importance are the flat lying multiple seams and thin seams (especially those in Appalachia). Steeply dipping coals, abandoned pillars, and exceptionally thick western coals may be important in some regions of subregions, but the limited tonnage available places them in a position of tertiary importance.
30 CFR 780.27 - Reclamation plan: Surface mining near underground mining.
Code of Federal Regulations, 2010 CFR
2010-07-01
... RECLAMATION AND OPERATION PLAN § 780.27 Reclamation plan: Surface mining near underground mining. For surface... 30 Mineral Resources 3 2010-07-01 2010-07-01 false Reclamation plan: Surface mining near... ENFORCEMENT, DEPARTMENT OF THE INTERIOR SURFACE COAL MINING AND RECLAMATION OPERATIONS PERMITS AND COAL...
30 CFR 75.1107-13 - Approval of other fire suppression devices.
Code of Federal Regulations, 2010 CFR
2010-07-01
... COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection Fire Suppression Devices and Fire-Resistant Hydraulic Fluids on Underground Equipment § 75.1107-13 Approval of... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Approval of other fire suppression devices. 75...
30 CFR 75.1905 - Dispensing of diesel fuel.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Dispensing of diesel fuel. 75.1905 Section 75... HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Diesel-Powered Equipment § 75.1905 Dispensing of diesel fuel. (a) Diesel-powered equipment in underground coal mines may be refueled only from safety cans...
30 CFR 72.520 - Diesel equipment inventory.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Diesel equipment inventory. 72.520 Section 72... HEALTH HEALTH STANDARDS FOR COAL MINES Diesel Particulate Matter-Underground Areas of Underground Coal Mines § 72.520 Diesel equipment inventory. (a) The operator of each mine that utilizes diesel equipment...
30 CFR 75.1905 - Dispensing of diesel fuel.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Dispensing of diesel fuel. 75.1905 Section 75... HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Diesel-Powered Equipment § 75.1905 Dispensing of diesel fuel. (a) Diesel-powered equipment in underground coal mines may be refueled only from safety cans...
30 CFR 72.520 - Diesel equipment inventory.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Diesel equipment inventory. 72.520 Section 72... HEALTH HEALTH STANDARDS FOR COAL MINES Diesel Particulate Matter-Underground Areas of Underground Coal Mines § 72.520 Diesel equipment inventory. (a) The operator of each mine that utilizes diesel equipment...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-29
... for OMB Review; Comment Request; Safety Standards for Underground Coal Mine Ventilation--Belt Entry... the Mine Safety and Health Administration (MSHA) sponsored information collection request (ICR) titled, ``Safety Standards for Underground Coal Mine Ventilation--Belt Entry Used as an Intake Air Course to...
30 CFR 75.812-1 - Qualified person.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Qualified person. 75.812-1 Section 75.812-1 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Underground High-Voltage Distribution § 75.812-1 Qualified...
30 CFR 77.403 - Mobile equipment; falling object protective structures (FOPS).
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Mobile equipment; falling object protective... AREAS OF UNDERGROUND COAL MINES Safeguards for Mechanical Equipment § 77.403 Mobile equipment; falling... underground coal mines shall be provided with substantial falling object protective structures (FOPS). FOPS...
30 CFR 77.403 - Mobile equipment; falling object protective structures (FOPS).
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Mobile equipment; falling object protective... AREAS OF UNDERGROUND COAL MINES Safeguards for Mechanical Equipment § 77.403 Mobile equipment; falling... underground coal mines shall be provided with substantial falling object protective structures (FOPS). FOPS...
30 CFR 77.403 - Mobile equipment; falling object protective structures (FOPS).
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Mobile equipment; falling object protective... AREAS OF UNDERGROUND COAL MINES Safeguards for Mechanical Equipment § 77.403 Mobile equipment; falling... underground coal mines shall be provided with substantial falling object protective structures (FOPS). FOPS...
30 CFR 72.520 - Diesel equipment inventory.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Diesel equipment inventory. 72.520 Section 72... HEALTH HEALTH STANDARDS FOR COAL MINES Diesel Particulate Matter-Underground Areas of Underground Coal Mines § 72.520 Diesel equipment inventory. (a) The operator of each mine that utilizes diesel equipment...
30 CFR 72.520 - Diesel equipment inventory.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Diesel equipment inventory. 72.520 Section 72... HEALTH HEALTH STANDARDS FOR COAL MINES Diesel Particulate Matter-Underground Areas of Underground Coal Mines § 72.520 Diesel equipment inventory. (a) The operator of each mine that utilizes diesel equipment...
30 CFR 72.520 - Diesel equipment inventory.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Diesel equipment inventory. 72.520 Section 72... HEALTH HEALTH STANDARDS FOR COAL MINES Diesel Particulate Matter-Underground Areas of Underground Coal Mines § 72.520 Diesel equipment inventory. (a) The operator of each mine that utilizes diesel equipment...
75 FR 52980 - Submission for OMB Review; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-30
.../maintaining): $303,512. Description: The Safety Standards for Underground Coal Mine Ventilation Belt Entry rule provides safety requirements for the use of the conveyor belt entry as a ventilation intake to... Underground Coal Mine Ventilation--Belt Entry Used as an Intake Air Course to Ventilate Working Sections and...
30 CFR 780.27 - Reclamation plan: Surface mining near underground mining.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 3 2011-07-01 2011-07-01 false Reclamation plan: Surface mining near underground mining. 780.27 Section 780.27 Mineral Resources OFFICE OF SURFACE MINING RECLAMATION AND ENFORCEMENT, DEPARTMENT OF THE INTERIOR SURFACE COAL MINING AND RECLAMATION OPERATIONS PERMITS AND COAL...
Code of Federal Regulations, 2010 CFR
2010-07-01
... 90 establishes the option of miners who are employed at underground coal mines or at surface work areas of underground coal mines and who have evidence of the development of pneumoconiosis to work in an... procedures for miners to exercise this option, and establishes the right of miners to retain their regular...
Causes of coal-miner absenteeism. Information Circular/1987
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peters, R.H.; Randolph, R.F.
The Bureau of Mines report describes several significant problems associated with absenteeism among underground coal miners. The vast empirical literature on employee absenteeism is reviewed, and a conceptual model of the factors that cause absenteeism among miners is presented. Portions of the model were empirically tested by performing correlational and multiple regression analyses on data collected from a group of 64 underground coal miners. The results of these tests are presented and discussed.
2006 SME annual meeting & 7th ICARD, March 26-29, 2006, St. Louis, Missouri. Pre-prints
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
2006-07-01
Subjects covered by the papers include: enhanced coalbed methane through carbon sequestration, application of laser surface coatings for raw coal screen wear resistance enhancement, application of cross-flow teeter-bed separator in the US coal industry, arsenic removal from drinking water, modelling of fire spread along combustibles in a mine entry, coal's role in sustaining society, real time characterisation of frother bubble thin films, diesel emissions, overcoming stress measurements form underground coal amines, dry jigging coal, estimation of roof strata strength, improving screen bowl centrifuge performance, installation of ventilation shaft at a New Mexico coal mine, evaluation of feasibility of CO{sub 2}more » sequestration in deep coal, robot-human control interaction in mining operations, small mine and contractor safety, coal dust explosibility meter, US coal mine fatalities versus age of mine, and water and slurry bulkheads in underground coal mines.« less
Thermal surface characteristics of coal fires 1 results of in-situ measurements
NASA Astrophysics Data System (ADS)
Zhang, Jianzhong; Kuenzer, Claudia
2007-12-01
Natural underground coal fires are fires in coal seams occurring subsurface. The fires are ignited through a process named spontaneous combustion, which occurs based on a natural reaction but is usually triggered through human interaction. Coal mining activities expose coal to the air. This leads to the exothermal oxidation of the carbon in the coal with the air's oxygen to CO 2 and - under certain circumstances - to spontaneous combustion. Coal fires occur in many countries world wide - however, currently the Chinese coal mining industry faces the biggest problems with coal fires. Coal fires destroy the valuable resource coal and furthermore lead to many environmental degradation phenomena such as the deterioration of surrounding vegetation, land subsidence and the emission of toxic gasses (CO, N 2O). They additionally contribute to the emission of green house relevant gasses such as CO 2 and CH 4 to the atmosphere. In this paper we present thermal characteristics of coal fires as measured in-situ during a field campaign to the Wuda coal fire area in south-central Inner Mongolia, China. Thermal characteristics include temperature anomaly measurements at the surface, spatial surface temperature profiles of fire areas and unaffected background areas, diurnal temperature profiles, and temperature measurements inside of coal fire induced cracks in the overlying bedrock. For all the measurements the effects of uneven solar heating through influences of slope and aspect are considered. Our findings show that coal fires result in strong or subtle thermal surface anomalies. Especially the latter can easily be influenced by heating of the surrounding background material through solar influences. Temperature variation of background rocks with different albedo, slope, aspect or vegetation cover can substantially influence the detectability of thermal anomalies. In the worst case coal fire related thermal anomalies can be completely masked by solar patterns during the daytime. Thus, night-time analysis is the most suitable for thermal anomaly mapping of underground coal fires, although this is not always feasible. The heat of underground coal fires only progresses very slowly through conduction in the rock material. Anomalies of coal fires completely covered by solid unfractured bedrock are very weak and were only measured during the night. The thermal pattern of underground coal fires manifested on the surface during the daytime is thus the pattern of cracks and vents, which occur due to the volume loss underground and which support radiation and convective energy transport of hot gasses. Inside coal fire temperatures can hardly be measured and can only be recorded if the glowing coal is exposed through a wider crack in the overlaying bedrock. Direct coal fire temperatures measured ranged between 233 °C and 854 °C. The results presented can substantially support the planning of thermal mapping campaigns, analyses of coal fire thermal anomalies in remotely sensed data, and can provide initial and boundary conditions for coal fire related numerical modeling. In a second paper named "Thermal Characteristics of Coal Fires 2: results of measurements on simulated coal fires" [ Zhang J., Kuenzer C., Tetzlaff A., Oettl D., Zhukov B., Wagner W., 2007. Thermal Characteristics of Coal Fires 2: Result of measurements on simulated coal fires. Accepted for publication at Journal of Applied Geophysics. doi:10.1016/j.jappgeo.2007.08.003] we report about thermal characteristics of simulated coal fires simulated under simplified conditions. The simulated set up allowed us to measure even more parameters under undisturbed conditions — especially inside fire temperatures. Furthermore we could demonstrate the differences between open surface coal fires and covered underground coal fires. Thermal signals of coal fires in near range thermal remotely sensed imagery from an observing tower and from an airplane are presented and discussed.
30 CFR 75.343 - Underground shops.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Underground shops. 75.343 Section 75.343... MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Ventilation § 75.343 Underground shops. (a) Underground shops shall be equipped with an automatic fire suppression system meeting the requirements of § 75.1107...
30 CFR 75.343 - Underground shops.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Underground shops. 75.343 Section 75.343... MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Ventilation § 75.343 Underground shops. (a) Underground shops shall be equipped with an automatic fire suppression system meeting the requirements of § 75.1107...
30 CFR 75.343 - Underground shops.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Underground shops. 75.343 Section 75.343... MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Ventilation § 75.343 Underground shops. (a) Underground shops shall be equipped with an automatic fire suppression system meeting the requirements of § 75.1107...
30 CFR 75.343 - Underground shops.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Underground shops. 75.343 Section 75.343... MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Ventilation § 75.343 Underground shops. (a) Underground shops shall be equipped with an automatic fire suppression system meeting the requirements of § 75.1107...
Application of Paste Backfill in Underground Coal Fires
NASA Astrophysics Data System (ADS)
Masniyom, M.; Drebenstedt, C.
2009-04-01
Coal fires are known from different coalfields worldwide. China, India, USA, Australia, Indonesia and South Africa are the main countries affected by coal fires. The fires is thermally intensive and cause numerous sinkholes, large-scale subsidence, air pollution, global warming, loss of mining productivity and increasing safety risk. The Wuda Inner Mongolia coalfield has been selected as a possible test area for paste backfill. The traditional methods, executed by fire fighting teams, by covering the coalfire areas with soil, blasting burning coal outcrops and injecting water in the subsurface fire pockets are continuously improved and extended. Initiatives to introduce modern techniques, such as backfill placement at fracture and borehole, to cool down the burning coal and cut off the air supply. This study is to investigate backfill materials and techniques suited for underground coal fires. Laboratory tests were carried out on physical, chemical and mechanical properties of different backfill materials and mixtures thereof. Special attention was paid to materials generated as by-products and other cheaply available materials e.g. fly ash from power plants. There is a good chance that one of the different material mixtures investigated can be used as a technically and economically viable backfill for underground coal fires.
75 FR 20918 - High-Voltage Continuous Mining Machine Standard for Underground Coal Mines
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-22
... DEPARTMENT OF LABOR Mine Safety and Health Administration 30 CFR Parts 18 and 75 RIN 1219-AB34 High-Voltage Continuous Mining Machine Standard for Underground Coal Mines Correction In rule document 2010-7309 beginning on page 17529 in the issue of Tuesday, April 6, 2010, make the following correction...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-29
... for OMB Review; Comment Request; Fire Protection in Underground Coal Mines ACTION: Notice. SUMMARY... information collection request (ICR) revision titled, ``Fire Protection in Underground Coal Mines,'' to the... sections of part 75 require fire drills to be conducted quarterly, equipment to be tested, and a record to...
30 CFR 75.813 - High-voltage longwalls; scope.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false High-voltage longwalls; scope. 75.813 Section 75.813 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Underground High-Voltage Distribution High-Voltage Longwalls § 75.813 High-voltage...
30 CFR 75.813 - High-voltage longwalls; scope.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false High-voltage longwalls; scope. 75.813 Section 75.813 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Underground High-Voltage Distribution High-Voltage Longwalls § 75.813 High-voltage...
Code of Federal Regulations, 2011 CFR
2011-07-01
... diesel-powered equipment other than generators and compressors. 72.502 Section 72.502 Mineral Resources... FOR COAL MINES Diesel Particulate Matter-Underground Areas of Underground Coal Mines § 72.502 Requirements for nonpermissible light-duty diesel-powered equipment other than generators and compressors. (a...
Code of Federal Regulations, 2010 CFR
2010-07-01
... diesel-powered equipment other than generators and compressors. 72.502 Section 72.502 Mineral Resources... FOR COAL MINES Diesel Particulate Matter-Underground Areas of Underground Coal Mines § 72.502 Requirements for nonpermissible light-duty diesel-powered equipment other than generators and compressors. (a...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-08
... Collection; Comment Request; High-Voltage Continuous Mining Machines Standards for Underground Coal Mines... Act of 1995. This program helps to assure that requested data can be provided in the desired format... maintains the safe use of high-voltage continuous mining machines in underground coal mines by requiring...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-14
... Program for Accumulations of Coal and Float Coal Dusts, Loose Coal, and Other Combustibles AGENCY: Mine... collection for developing and updating a cleanup program for accumulations of coal and float coal dusts, loose coal, and other combustibles in underground coal mines. DATES: All comments must be postmarked or...
Requirements for the conceptual design of advanced underground coal extraction systems
NASA Technical Reports Server (NTRS)
Gangal, M. D.; Lavin, M. L.
1981-01-01
Conceptual design requirements are presented for underground coal mining systems having substantially improved performance in the areas of production cost and miner safety. Mandatory performance levels are also set for miner health, environmental impact, and coal recovery. In addition to mandatory design goals and constraints, a number of desirable system characteristics are identified which must be assessed in terms of their impact on production cost and their compatibility with other system elements. Although developed for the flat lying, moderately thick seams of Central Appalachia, these requirements are designed to be easily adaptable to other coals.
VRLane: a desktop virtual safety management program for underground coal mine
NASA Astrophysics Data System (ADS)
Li, Mei; Chen, Jingzhu; Xiong, Wei; Zhang, Pengpeng; Wu, Daozheng
2008-10-01
VR technologies, which generate immersive, interactive, and three-dimensional (3D) environments, are seldom applied to coal mine safety work management. In this paper, a new method that combined the VR technologies with underground mine safety management system was explored. A desktop virtual safety management program for underground coal mine, called VRLane, was developed. The paper mainly concerned about the current research advance in VR, system design, key techniques and system application. Two important techniques were introduced in the paper. Firstly, an algorithm was designed and implemented, with which the 3D laneway models and equipment models can be built on the basis of the latest mine 2D drawings automatically, whereas common VR programs established 3D environment by using 3DS Max or the other 3D modeling software packages with which laneway models were built manually and laboriously. Secondly, VRLane realized system integration with underground industrial automation. VRLane not only described a realistic 3D laneway environment, but also described the status of the coal mining, with functions of displaying the run states and related parameters of equipment, per-alarming the abnormal mining events, and animating mine cars, mine workers, or long-wall shearers. The system, with advantages of cheap, dynamic, easy to maintenance, provided a useful tool for safety production management in coal mine.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bartke, T.C.
Under the US Department of Energy's Underground-Coal-Conversion program, four field tests were completed in 1979 and preparations were begun in 1980 for two additional field tests to be operated in 1981. The Laramie Energy Technology Center (LETC) and Sandia National Laboratories (SNL) completed Hanna IV, an air gasification test in Wyoming subbituminous coal. The Morgantown Energy Technology Center (METC) completed Pricetown 1, an air gasification test in West Virginia bituminous coal. Lawrence Livermore National Laboratory (LLNL) completed Hoe Creek 3, a steam-oxygen gasification test in Wyoming subbituminous coal. Gulf Research and Development Co. completed Steeply Dipping Beds (SDB) Test 1,more » primarily an air gasification test in Wyoming subbituminous coal and the first SDB test in the US. In 1980, Gulf R and D Co. began preparation of SDB Test 2, scheduled for operation in the fall of 1981. The DOE project teams at LETC, METC, LLNL, and SNL, in association with the Washington Irrigation and Development Co. (WIDCo), Washington Water Power (WWP), and the State of Washington, are preparing a field test site in the Centralia-Chehalis coal district of Washington. A series of large coal block tests will be completed prior to the field test, scheduled for operation in 1982 or 1983. This field test will utilize a directionally drilled link and steam-oxygen gasification system. This paper summarizes the results of the four recently completed field tests and the plans for additional tests.« less
Tchorz-Trzeciakiewicz, Dagmara Eulalia; Parkitny, Tomasz
2015-11-01
The surveys of radon concentrations in the Underground Tourist Route "Coal Mine" were carried out using passive and active measurement techniques. Passive methods with application of Solid State Nuclear Track Detectors LR115 were used at 4 points in years 2004-2007 and at 21 points in year 2011. These detectors were exchanged at the beginning of every season in order to get information about seasonal and spatial changes of radon concentrations. The average radon concentration noted in this facility was 799 Bq m(-3) and is consistent with radon concentrations noted in Polish coal mines. Seasonal variations, observed in this underground tourist route, were as follows: the highest radon concentrations were noted during summers, the lowest during winters, during springs and autumns intermediate but higher in spring than in autumn. The main external factor that affected seasonal changes of radon concentrations was the seasonal variation of outside temperature. No correlation between seasonal variations of radon concentrations and seasonal average atmospheric pressures was found. Spatial variations of radon concentrations corresponded with air movements inside the Underground Tourist Route "Coal Mine". The most vivid air movements were noted along the main tunnel in adit and at the place located near no blinded (in the upper part) shaft. Daily variations of radon concentrations were recorded in May 2012 using RadStar RS-230 as the active measurement technique. Typical daily variations of radon concentrations followed the pattern that the highest radon concentrations were recorded from 8-9 a.m. to 7-8 p.m. and the lowest during nights. The main factor responsible for hourly variations of radon concentrations was the daily variation of outside temperatures. No correlations were found between radon concentration and other meteorological parameters such as atmospheric pressure, wind velocity or precipitation. Additionally, the influence of human factor on radon concentrations was noticed. As human factor, we consider open entrance door during restorations works carried out inside the underground facility. Comprehensive surveys of radon concentrations in the Underground Tourist Route "Coal Mine", which included hourly, seasonal and spatial measurements, have revealed that radon can be the excellent tracer of air movements inside the underground facilities that are not equipped with mechanical ventilation system. The main external factor that affects hourly, seasonal and even spatial changes of radon concentrations inside Underground Tourist Route "Coal Mine" is the variation of outside temperature. The maximum effective dose received by employees during 2000 working hours in a year was 5.8 mSv y(-1) and the minimum was 3.5 mSv y(-1). Tourist guides, who usually spend underground about 1000 h y(-1), received effective dose from 1.7 mSv y(-1) to 2.3 mSv y(-1). According to Polish Law, employees, receiving effective dose for occupational exposure higher than 1 mSv y(-1) but below 6 mSv y(-1), are allocated to category B of workers and the level of radiation in their place of work should be controlled and continuously monitored. The radiation monitoring system in the Underground Tourist Route "Coal Mine" does not exist. None of Polish tourist routes or caves has installed radiation monitoring system although effective doses received by employees, in some of them, exceed values defined by law. Effective dose received by tourist during one trip was lower than 0.001 mSv y(-1) and risk of cancer induction was lower than 0.00001%. The probability, that tourists inside the Underground Tourist Route "Coal Mine" receive effective dose exceeding allowable annual limit for members of the public of 1 mSv y(-1) does not exist. The Underground Tourist Route Coal Mine is a safe place for tourists from radiological point of view. Copyright © 2015 Elsevier Ltd. All rights reserved.
The report gives results of EPA research into the emission processes and control strategies associated with underground coal mines in the U.S. (NOTE: Methane is a greenhouse gas in the atmosphere which ranks behind carbon dioxide as the second largest contributor to global warmin...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-18
... Final EIS for the Leasing and Underground Mining of the Greens Hollow Federal Coal Lease Tract (UTU... Mining of the Greens Hollow Federal Coal Lease Tract UTU-84102. Supplemental analyses are required to... mining methods, with foreseeable access from existing adjacent leases. The Forest Service and BLM have...
Code of Federal Regulations, 2011 CFR
2011-10-01
... Federal coal; ensure production practices that prevent wasting or loss of coal or other resources; avoid unnecessary damage to coal-bearing or mineral-bearing formations; ensure MER of Federal coal; ensure that... regulation of surface and underground coal mining operations; require an accurate record and accounting of...
Code of Federal Regulations, 2012 CFR
2012-10-01
... Federal coal; ensure production practices that prevent wasting or loss of coal or other resources; avoid unnecessary damage to coal-bearing or mineral-bearing formations; ensure MER of Federal coal; ensure that... regulation of surface and underground coal mining operations; require an accurate record and accounting of...
Code of Federal Regulations, 2013 CFR
2013-10-01
... Federal coal; ensure production practices that prevent wasting or loss of coal or other resources; avoid unnecessary damage to coal-bearing or mineral-bearing formations; ensure MER of Federal coal; ensure that... regulation of surface and underground coal mining operations; require an accurate record and accounting of...
Code of Federal Regulations, 2014 CFR
2014-10-01
... Federal coal; ensure production practices that prevent wasting or loss of coal or other resources; avoid unnecessary damage to coal-bearing or mineral-bearing formations; ensure MER of Federal coal; ensure that... regulation of surface and underground coal mining operations; require an accurate record and accounting of...
Computational Studies for Underground Coal Gasification (UCG) Process
NASA Astrophysics Data System (ADS)
Chatterjee, Dipankar
2017-07-01
Underground coal gasification (UCG) is a well proven technology in order to access the coal lying either too deep underground, or is otherwise too costly to be extracted using the conventional mining methods. UCG product gas is commonly used as a chemical feedstock or as fuel for power generation. During the UCG process, a cavity is formed in the coal seam during its conversion to gaseous products. The cavity grows in a three-dimensional fashion as the gasification proceeds. The UCG process is indeed a result of several complex interactions of various geo-thermo-mechanical processes such as the fluid flow, heat and mass transfer, chemical reactions, water influx, thermo-mechanical failure, and other geological aspects. The rate of the growth of this cavity and its shape will have a significant impact on the gas flow patterns, chemical kinetics, temperature distributions, and finally the quality of the product gas. It has been observed that there is insufficient information available in the literature to provide clear insight into these issues. It leaves us with a great opportunity to investigate and explore the UCG process, both from the experimental as well as theoretical perspectives. In the development and exploration of new research, experiment is undoubtedly very important. However, due to the excessive cost involvement with experimentation it is not always recommended for the complicated process like UCG. Recently, with the advent of the high performance computational facilities it is quite possible to make alternative experimentation numerically of many physically involved problems using certain computational tools like CFD (computational fluid dynamics). In order to gain a comprehensive understanding of the underlying physical phenomena, modeling strategies have frequently been utilized for the UCG process. Keeping in view the above, the various modeling strategies commonly deployed for carrying out mathematical modeling of UCG process are described here in a concise manner. The available strategies are categorized in several groups and their salient features are discussed in order to have a good understanding of the underlying physical phenomena. This would likely to be a valuable documentation in order to understand the physical process of UCG and will pave to formulate new and involved modeling and simulation techniques for computationally modeling the UCG process.
Subsidence Induced by Underground Extraction
Galloway, Devin L.
2016-01-01
Subsidence induced by underground extraction is a class of human-induced (anthropogenic) land subsidence that principally is caused by the withdrawal of subsurface fluids (groundwater, oil, and gas) or by the underground mining of coal and other minerals.
Geomorphology of coal seam fires
NASA Astrophysics Data System (ADS)
Kuenzer, Claudia; Stracher, Glenn B.
2012-02-01
Coal fires occur in underground natural coal seams, in exposed surface seams, and in coal storage or waste piles. The fires ignite through spontaneous combustion or natural or anthropogenic causes. They are reported from China, India, USA, South Africa, Australia, and Russia, as well as many other countries. Coal fires lead to loss of a valuable resource (coal), the emission of greenhouse-relevant and toxic gases, and vegetation deterioration. A dangerous aspect of the fires is the threat to local mines, industries, and settlements through the volume loss underground. Surface collapse in coal fire areas is common. Thus, coal fires are significantly affecting the evolution of the landscape. Based on more than a decade of experience with in situ mapping of coal fire areas worldwide, a general classification system for coal fires is presented. Furthermore, coal seam fire geomorphology is explained in detail. The major landforms associated with, and induced by, these fires are presented. The landforms include manifestations resulting from bedrock surface fracturing, such as fissures, cracks, funnels, vents, and sponges. Further manifestations resulting from surface bedrock subsidence include sinkholes, trenches, depressions, partial surface subsidence, large surface subsidence, and slides. Additional geomorphologic coal fire manifestations include exposed ash layers, pyrometamorphic rocks, and fumarolic minerals. The origin, evolution, and possible future development of these features are explained, and examples from in situ surveys, as well as from high-resolution satellite data analyses, are presented. The geomorphology of coal fires has not been presented in a systematic manner. Knowledge of coal fire geomorphology enables the detection of underground coal fires based on distinct surface manifestations. Furthermore, it allows judgments about the safety of coal fire-affected terrain. Additionally, geomorphologic features are indicators of the burning stage of fires. Finally, coal fire geomorphology helps to explain landscape features whose occurrence would otherwise not be understood. Although coal fire-induced thermal anomalies and gas release are also indications of coal fire activity, as addressed by many investigators, no assessment is complete without sound geomorphologic mapping of the fire-induced geomorphologic features.
Psycho-social aspects of productivity in underground coal mining
DOE Office of Scientific and Technical Information (OSTI.GOV)
Akin, G.
1981-10-01
The psychosocial aspects of productivity in underground coal mining were investigated. The following topics were studied: (1) labor productivity in deep mines and the explanations for productivity changes; (2) current concepts and research on psychosocial factors in productivity; (3) a survey of experiments in productivity improvement (4) the impact of the introduction of new technology on the social system and the way that it accomplishes production (5) a clinical study of a coal mining operation, model described how production is actually accomplished by workers at the coal face; and (6) implications and recommendations for new technology design, implementation and ongoingmore » management.« less
30 CFR 75.1709 - Accumulations of methane and coal dust on surface coal-handling facilities.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Accumulations of methane and coal dust on surface coal-handling facilities. 75.1709 Section 75.1709 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES...
30 CFR 75.1709 - Accumulations of methane and coal dust on surface coal-handling facilities.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Accumulations of methane and coal dust on surface coal-handling facilities. 75.1709 Section 75.1709 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES...
30 CFR 75.1709 - Accumulations of methane and coal dust on surface coal-handling facilities.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Accumulations of methane and coal dust on surface coal-handling facilities. 75.1709 Section 75.1709 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES...
30 CFR 75.1709 - Accumulations of methane and coal dust on surface coal-handling facilities.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Accumulations of methane and coal dust on surface coal-handling facilities. 75.1709 Section 75.1709 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
In fiscal 1982, the mine safety record improved in several categories over the previous year, but declined in others. There were 220 mining deaths in fiscal year 1982 compared to 222 fatalities in 1981. In coal mining, there were 160 fatalities in fiscal 1982 compared with 131 the previous year. In metal and nonmetal mining in fiscal 1982, there were 60 fatalities, compared to 91 deaths recorded in fiscal 1981. In coal mining, the fatality rate, which factors in employment variations, was .07 per 200,000 employee-hours worked in fiscal 1982 compared to a .06 rate during the previous year. Inmore » metal and nonmetal mining, the fatality rate per 200,000 employee-hours was .04 in fiscal 1982 compared with .03 the previous year. In both industries, the rates of all injuries declined. On Dec. 7, 1981, an underground coal mine dust explosion took the lives of eight miners at the Adkins Coal Co,'s No. 11 mine at Kite, Knott County, KY. A day later, Dec. 8, 1981, an underground coal mine explosion killed 13 miners at Grundy Mining Co.'s No. 21 mine at Whitwell, Marion County, Tenn. During the following month, on Jan. 20, 1982, another coal mine dust explosion killed seven underground coal miners at the RFH mine in Craynor, Floyd County, KY. 7 figs., 33 tabs.« less
30 CFR 75.1712-6 - Underground sanitary facilities; installation and maintenance.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Underground sanitary facilities; installation... Miscellaneous § 75.1712-6 Underground sanitary facilities; installation and maintenance. (a) Except as provided in § 75.1712-7, each operator of an underground coal mine shall provide and maintain one sanitary...
30 CFR 75.1712-6 - Underground sanitary facilities; installation and maintenance.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Underground sanitary facilities; installation... Miscellaneous § 75.1712-6 Underground sanitary facilities; installation and maintenance. (a) Except as provided in § 75.1712-7, each operator of an underground coal mine shall provide and maintain one sanitary...
30 CFR 75.1712-6 - Underground sanitary facilities; installation and maintenance.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Underground sanitary facilities; installation... Miscellaneous § 75.1712-6 Underground sanitary facilities; installation and maintenance. (a) Except as provided in § 75.1712-7, each operator of an underground coal mine shall provide and maintain one sanitary...
30 CFR 75.1712-6 - Underground sanitary facilities; installation and maintenance.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Underground sanitary facilities; installation... Miscellaneous § 75.1712-6 Underground sanitary facilities; installation and maintenance. (a) Except as provided in § 75.1712-7, each operator of an underground coal mine shall provide and maintain one sanitary...
30 CFR 75.1712-6 - Underground sanitary facilities; installation and maintenance.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Underground sanitary facilities; installation... Miscellaneous § 75.1712-6 Underground sanitary facilities; installation and maintenance. (a) Except as provided in § 75.1712-7, each operator of an underground coal mine shall provide and maintain one sanitary...
43 CFR 3484.1 - Performance standards for exploration and surface and underground mining.
Code of Federal Regulations, 2014 CFR
2014-10-01
... officer. Operators/lessees of underground coal mines shall adopt measures consistent with known technology... subsequent operations on the quantity, quality, or pressure of ground water or mine gases only with the... mines—(1) Underground resource recovery. Underground mining operations shall be conducted so as to...
43 CFR 3484.1 - Performance standards for exploration and surface and underground mining.
Code of Federal Regulations, 2011 CFR
2011-10-01
... officer. Operators/lessees of underground coal mines shall adopt measures consistent with known technology... subsequent operations on the quantity, quality, or pressure of ground water or mine gases only with the... mines—(1) Underground resource recovery. Underground mining operations shall be conducted so as to...
A life-cycle description of underground coal mining
NASA Technical Reports Server (NTRS)
Lavin, M. L.; Borden, C. S.; Duda, J. R.
1978-01-01
An initial effort to relate the major technological and economic variables which impact conventional underground coal mining systems, in order to help identify promising areas for advanced mining technology is described. The point of departure is a series of investment analyses published by the United States Bureau of Mines, which provide both the analytical framework and guidance on a choice of variables.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Buchsbaum, L.
Phoenix Coal currently operates 3 surface coal mines in Western Kentucky and have recently obtained the permits to construct their first underground mine. The expansion of the Phoenix Coal company since its formation in July 2004 is described. 4 photos.
30 CFR 77.200 - Surface installations; general.
Code of Federal Regulations, 2010 CFR
2010-07-01
... AND HEALTH MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL... other facilities (including custom coal preparation) shall be maintained in good repair to prevent accidents and injuries to employees. ...
Government regulation of occupational safety: underground coal mine accidents 1973-75.
Boden, L I
1985-01-01
The purpose of this paper is to determine the influence of federal mine safety inspections on underground coal mine accidents. An economic incentives model is developed to relate federal enforcement activities to accident rates. The determinants of accident rates are analyzed for 535 coal mines during the period 1973-75. Estimates based on these data when applied to the model indicate that increasing inspections by 25 per cent would have produced a 13 per cent decline in fatal accidents and an 18 per cent decline in disabling accidents. PMID:3985237
Government regulation of occupational safety: underground coal mine accidents 1973-75.
Boden, L I
1985-05-01
The purpose of this paper is to determine the influence of federal mine safety inspections on underground coal mine accidents. An economic incentives model is developed to relate federal enforcement activities to accident rates. The determinants of accident rates are analyzed for 535 coal mines during the period 1973-75. Estimates based on these data when applied to the model indicate that increasing inspections by 25 per cent would have produced a 13 per cent decline in fatal accidents and an 18 per cent decline in disabling accidents.
Early detection of mine fire in underground by using smell detectors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ohga, Kotaro; Higuchi, Kiyoshi
1995-12-31
In our laboratory, a new detection system using smell detectors was developed to detect the spontaneous combustion of coal and the combustion of other materials used underground. Laboratory experiments were carried out on several kinds of coals, including South African coals, and machine oil, wood and rubber used in belt conveyers. The following results were obtained: (1) Spontaneous combustion of coal can be detected earlier by smell detectors than by conventional CO detection methods. (2) There were no differences in the results using different kinds of coal. (3) Combustion d other materials can also be detected earlier by this systemmore » than by conventional detectors for gas and smoke. (4) Use of this detection system enables one to discern the source of the combustion gases, whether it be coal, wood, oil or rubber.« less
30 CFR 817.59 - Coal recovery.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 3 2013-07-01 2013-07-01 false Coal recovery. 817.59 Section 817.59 Mineral... PERFORMANCE STANDARDS PERMANENT PROGRAM PERFORMANCE STANDARDS-UNDERGROUND MINING ACTIVITIES § 817.59 Coal... conservation of the coal, while utilizing the best technology currently available to maintain environmental...
30 CFR 817.59 - Coal recovery.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 3 2014-07-01 2014-07-01 false Coal recovery. 817.59 Section 817.59 Mineral... PERFORMANCE STANDARDS PERMANENT PROGRAM PERFORMANCE STANDARDS-UNDERGROUND MINING ACTIVITIES § 817.59 Coal... conservation of the coal, while utilizing the best technology currently available to maintain environmental...
30 CFR 817.59 - Coal recovery.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 3 2010-07-01 2010-07-01 false Coal recovery. 817.59 Section 817.59 Mineral... PERFORMANCE STANDARDS PERMANENT PROGRAM PERFORMANCE STANDARDS-UNDERGROUND MINING ACTIVITIES § 817.59 Coal... conservation of the coal, while utilizing the best technology currently available to maintain environmental...
30 CFR 817.59 - Coal recovery.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 3 2011-07-01 2011-07-01 false Coal recovery. 817.59 Section 817.59 Mineral... PERFORMANCE STANDARDS PERMANENT PROGRAM PERFORMANCE STANDARDS-UNDERGROUND MINING ACTIVITIES § 817.59 Coal... conservation of the coal, while utilizing the best technology currently available to maintain environmental...
30 CFR 817.59 - Coal recovery.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 3 2012-07-01 2012-07-01 false Coal recovery. 817.59 Section 817.59 Mineral... PERFORMANCE STANDARDS PERMANENT PROGRAM PERFORMANCE STANDARDS-UNDERGROUND MINING ACTIVITIES § 817.59 Coal... conservation of the coal, while utilizing the best technology currently available to maintain environmental...
ESTIMATE OF GLOBAL METHANE EMISSIONS FROM COAL MINES
Country-specific emissions of methane (CH4) from underground coal mines, surface coal mines, and coal crushing and transport operations are estimated for 1989. Emissions for individual countries are estimated by using two sets of regression equations (R2 values range from 0.56 to...
Code of Federal Regulations, 2010 CFR
2010-07-01
... for underground sanitary facilities. 75.1712-8 Section 75.1712-8 Mineral Resources MINE SAFETY AND...-UNDERGROUND COAL MINES Miscellaneous § 75.1712-8 Application for waiver of location requirements for underground sanitary facilities. Applications for waivers of the location requirements of § 75.1712-6 shall be...
Code of Federal Regulations, 2014 CFR
2014-07-01
... for underground sanitary facilities. 75.1712-8 Section 75.1712-8 Mineral Resources MINE SAFETY AND...-UNDERGROUND COAL MINES Miscellaneous § 75.1712-8 Application for waiver of location requirements for underground sanitary facilities. Applications for waivers of the location requirements of § 75.1712-6 shall be...
Code of Federal Regulations, 2012 CFR
2012-07-01
... for underground sanitary facilities. 75.1712-8 Section 75.1712-8 Mineral Resources MINE SAFETY AND...-UNDERGROUND COAL MINES Miscellaneous § 75.1712-8 Application for waiver of location requirements for underground sanitary facilities. Applications for waivers of the location requirements of § 75.1712-6 shall be...
Code of Federal Regulations, 2013 CFR
2013-07-01
... for underground sanitary facilities. 75.1712-8 Section 75.1712-8 Mineral Resources MINE SAFETY AND...-UNDERGROUND COAL MINES Miscellaneous § 75.1712-8 Application for waiver of location requirements for underground sanitary facilities. Applications for waivers of the location requirements of § 75.1712-6 shall be...
Code of Federal Regulations, 2011 CFR
2011-07-01
... for underground sanitary facilities. 75.1712-8 Section 75.1712-8 Mineral Resources MINE SAFETY AND...-UNDERGROUND COAL MINES Miscellaneous § 75.1712-8 Application for waiver of location requirements for underground sanitary facilities. Applications for waivers of the location requirements of § 75.1712-6 shall be...
30 CFR 49.50 - Certification of coal mine rescue teams.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Certification of coal mine rescue teams. 49.50... TRAINING MINE RESCUE TEAMS Mine Rescue Teams for Underground Coal Mines § 49.50 Certification of coal mine... coal mine, the mine operator shall send the District Manager an annual statement certifying that each...
30 CFR 49.50 - Certification of coal mine rescue teams.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Certification of coal mine rescue teams. 49.50... TRAINING MINE RESCUE TEAMS Mine Rescue Teams for Underground Coal Mines § 49.50 Certification of coal mine... coal mine, the mine operator shall send the District Manager an annual statement certifying that each...
30 CFR 49.50 - Certification of coal mine rescue teams.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Certification of coal mine rescue teams. 49.50... TRAINING MINE RESCUE TEAMS Mine Rescue Teams for Underground Coal Mines § 49.50 Certification of coal mine... coal mine, the mine operator shall send the District Manager an annual statement certifying that each...
30 CFR 75.501 - Permissible electric face equipment; coal seams above water table.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Permissible electric face equipment; coal seams..., DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Electrical Equipment-General § 75.501 Permissible electric face equipment; coal seams above water table. [Statutory...
30 CFR 49.50 - Certification of coal mine rescue teams.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Certification of coal mine rescue teams. 49.50... TRAINING MINE RESCUE TEAMS Mine Rescue Teams for Underground Coal Mines § 49.50 Certification of coal mine... coal mine, the mine operator shall send the District Manager an annual statement certifying that each...
30 CFR 75.501 - Permissible electric face equipment; coal seams above water table.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Permissible electric face equipment; coal seams..., DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Electrical Equipment-General § 75.501 Permissible electric face equipment; coal seams above water table. [Statutory...
30 CFR 49.50 - Certification of coal mine rescue teams.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Certification of coal mine rescue teams. 49.50... TRAINING MINE RESCUE TEAMS Mine Rescue Teams for Underground Coal Mines § 49.50 Certification of coal mine... coal mine, the mine operator shall send the District Manager an annual statement certifying that each...
30 CFR 75.501 - Permissible electric face equipment; coal seams above water table.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Permissible electric face equipment; coal seams..., DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Electrical Equipment-General § 75.501 Permissible electric face equipment; coal seams above water table. [Statutory...
30 CFR 75.501 - Permissible electric face equipment; coal seams above water table.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Permissible electric face equipment; coal seams..., DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Electrical Equipment-General § 75.501 Permissible electric face equipment; coal seams above water table. [Statutory...
77 FR 61406 - Agency Forms Undergoing Paperwork Reduction Act Review
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-09
... Underground Coal Mining (0920-0835 Expiration 12/31/2012)--Revision--National Institute for Occupational... occupational safety and health problems in the coal mining industry. In recent years, coal mining safety has... health, the U.S. relies on coal mining to meet its electricity needs. For this reason, the coal mining...
75 FR 17511 - Coal Mine Dust Sampling Devices
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-06
... Part III Department of Labor Mine Safety and Health Adminisration 30 CFR Parts 18, 74, and 75 Coal Mine Dust Sampling Devices; High-Voltage Continuous Mining Machine Standard for Underground Coal Mines...-AB61 Coal Mine Dust Sampling Devices AGENCY: Mine Safety and Health Administration, Labor. ACTION...
30 CFR 71.501 - Sanitary toilet facilities; maintenance.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Section 71.501 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES Sanitary Toilet Facilities at Surface Worksites of Surface Coal Mines § 71.501 Sanitary...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
The goal of the US Department of Energy (DOE) Underground Coal Conversion (UCC) program is to develop the technology to produce clean fuels from coal deposits that are unsuitable for commercial exploitation by conventional mining techniques. The highest priority is to develop and demonstrate, in conjunction with industry, a commercially feasible process for underground gasification of low-rank coal in the 1985 to 1987 time period. The DOE program has stimulated industry interest and activity in developing UCC technology. Several major energy corporations and utilities have invested private funds in UCC research and development (R and D) projects. Results of themore » program to date indicate that, while UCC is technically feasible, it still contains some process unknowns, environmental risks, and economic risks that require R and D. In order to contribute to the national energy goals, a strong DOE program that incorporates maximum industry involvement is planned. The program's strategy is to remove the high-risk elements of UCC by resolving technical, environmental, and economic uncertainties. This will enable industry to assume responsibility for commercialization of the technology. Thus, the elements of the program have been designed to: provide detailed design and operational data that industry can scale-up with confidence; provide accurate and complete cost estimates that can be scaled-up and will allow comparison with alternative processes; provide detailed environmental impact and control data to allow industry to implement projects that will meet applicable standards; verify the reliability of continuous operation of UCC processes; and show that UCC processes have the flexibility to meet a variety of commercial needs.« less
An overview of the geological controls in underground coal gasification
NASA Astrophysics Data System (ADS)
Mohanty, Debadutta
2017-07-01
Coal’s reign will extend well into this millennium as the global demand for coal is expected to increase on average by 2-1% per year through 2019. Enhanced utilization of the domestic coal resource through clean coal technologies is necessary to meet the energy needs while achieving reduced emissions. Underground coal gasification (UCG) is one of such potential technologies. Geology of the area plays decisive role throughout the life of a UCG project and imperative for every phase of the project cycle starting from planning, site selection, design to cessation of operations and restoration of the site. Impermeable over/underlying strata with low porosity and less deformation are most suitable for UCG processes as they act as seal between the coal seam and the surrounding aquifers while limiting the degree of subsidence. Inrush of excess water into the gasification chamber reduces the efficacy of the process and may even quench the reactions in progress. Presence of fresh water aquifer in the vicinity of target coal seam should be abandoned in order to avoid groundwater contamination. UCG is not a proven technology that is still evolving and there are risks that need to be monitored and managed. Effective shutdown programme should intend at minimising the post-burn contaminant generation by flushing out potential organic and inorganic contaminants from the underground strata and treating contaminants, and to restore ground water quality to near baseline conditions.
Pathological study of the prevalence of silicosis among coal miners in Iran: A case history
NASA Astrophysics Data System (ADS)
Zare Naghadehi, Masoud; Sereshki, Farhang; Mohammadi, F.
2014-02-01
One of the most hazardous diseases that is commonly associated with the coal mining industry is Silicosis which caused by dust inhalation. This disease occurs as a result of prolonged breathing of dust containing silica (quartz). The generation of coal mine dust during underground and surface coal mining is the most significant source of coal dust exposure. Silica dust develops scar tissue inside the lungs which reduces the lungs ability to extract oxygen from the air. All miners working in underground and surface coal mines are at risk of being exposed to mine dust containing silica. In this study, cases with pathologic diagnosis of silicosis during seven years period between 2000 and 2007 were retrieved, from the pathologic file of Department of Pathology, Massih Daneshvary Hospital in Iran. Results of this case study showed the great effects of dust exposure and inhalation from the viewpoint of symptoms especially between the miners.
Upper Cretaceous bituminous coal deposits of the Olmos Formation, Maverick County, Texas
Hook, Robert W.; Warwick, Peter D.; SanFilipo, John R.; Warwick, Peter D.; Karlsen, Alexander K.; Merrill, Matthew D.; Valentine, Brett J.
2011-01-01
This report describes the bituminous coal deposits of the Olmos Formation (Navarro Group, Upper Cretaceous; Figures 1, 2) of Maverick County in south Texas. Although these were not evaluated quantitatively as part of the current Gulf Coastal Plain coal-resource assessment, a detailed review is presented in this chapter.Prior to the late 1920s, these coal beds were mined underground on a large scale in the vicinity of Eagle Pass, Texas (Figure 1). Since the 1970s, Olmos Formation coals have been mined extensively in both underground and surface mines in nearby Coahuila, Mexico, to supply mine-mouth fuel for power generation at a plant nearby. A tract northeast of Eagle Pass was permitted in the late 1990s for surface mining. In east-central Maverick County, a coalbed methane field is being developed in coal beds of the lower part of the Olmos Formation (Barker et al., 2002; Scott, 2003).
Geomechanical Analysis of Underground Coal Gasification Reactor Cool Down for Subsequent CO2 Storage
NASA Astrophysics Data System (ADS)
Sarhosis, Vasilis; Yang, Dongmin; Kempka, Thomas; Sheng, Yong
2013-04-01
Underground coal gasification (UCG) is an efficient method for the conversion of conventionally unmineable coal resources into energy and feedstock. If the UCG process is combined with the subsequent storage of process CO2 in the former UCG reactors, a near-zero carbon emission energy source can be realised. This study aims to present the development of a computational model to simulate the cooling process of UCG reactors in abandonment to decrease the initial high temperature of more than 400 °C to a level where extensive CO2 volume expansion due to temperature changes can be significantly reduced during the time of CO2 injection. Furthermore, we predict the cool down temperature conditions with and without water flushing. A state of the art coupled thermal-mechanical model was developed using the finite element software ABAQUS to predict the cavity growth and the resulting surface subsidence. In addition, the multi-physics computational software COMSOL was employed to simulate the cavity cool down process which is of uttermost relevance for CO2 storage in the former UCG reactors. For that purpose, we simulated fluid flow, thermal conduction as well as thermal convection processes between fluid (water and CO2) and solid represented by coal and surrounding rocks. Material properties for rocks and coal were obtained from extant literature sources and geomechanical testings which were carried out on samples derived from a prospective demonstration site in Bulgaria. The analysis of results showed that the numerical models developed allowed for the determination of the UCG reactor growth, roof spalling, surface subsidence and heat propagation during the UCG process and the subsequent CO2 storage. It is anticipated that the results of this study can support optimisation of the preparation procedure for CO2 storage in former UCG reactors. The proposed scheme was discussed so far, but not validated by a coupled numerical analysis and if proved to be applicable it could provide a significant optimisation of the UCG process by means of CO2 storage efficiency. The proposed coupled UCG-CCS scheme allows for meeting EU targets for greenhouse gas emissions and increases the coal yield otherwise impossible to exploit.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
The US Department of Energy is funding an underground coal gasification (UCG) project in steeply dipping coal beds (SDB), at North Knobs, about 8 miles west of Rawlins, Carbon County, Wyoming. The project is being conducted to determine the technical, economic and environmental viability of such a technology. The development of SDB is an interesting target for UCG since such beds contain coals not normally mineable economically by ordinary techniques. Although the underground gasification of SDB has not been attempted in the US, Soviet experience and theoretical work indicate that the gasification of SDB in place offers all the advantagesmore » of underground gasification of horizontal coal seams plus some unique characteristics. The steep angle of dip helps to channel the produced gases up dip to offtake holes and permits the ash and rubble to fall away from the reaction zone helping to mitigate the blocking of the reaction zone in swelling coals. The intersection of SDB with the surface makes the seam accessible for drilling and other preparation. The tests at the North Knobs site will consist of three tests, lasting 20, 80 and 80 days, respectively. A total of 9590 tons of coal is expected to be gasified, with surface facilities utilizing 15 acres of the total section of land. The environmental effects of the experiment are expected to be very small. The key environmental impact is potential groundwater contamination by reaction products from coal gasification. There is good evidence that the surrounding coal effectively blocks the migration of these contaminants.« less
30 CFR 77.313 - Wet-coal feedbins; low-level indicators.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Wet-coal feedbins; low-level indicators. 77.313 Section 77.313 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND...
30 CFR 77.313 - Wet-coal feedbins; low-level indicators.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Wet-coal feedbins; low-level indicators. 77.313 Section 77.313 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND...
30 CFR 77.313 - Wet-coal feedbins; low-level indicators.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Wet-coal feedbins; low-level indicators. 77.313 Section 77.313 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND...
30 CFR 77.313 - Wet-coal feedbins; low-level indicators.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Wet-coal feedbins; low-level indicators. 77.313 Section 77.313 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND...
30 CFR 77.313 - Wet-coal feedbins; low-level indicators.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Wet-coal feedbins; low-level indicators. 77.313 Section 77.313 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND...
30 CFR 77.1000-1 - Filing of plan.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES Ground..., with the MSHA Coal Mine Safety and Health district office for the district in which the mine is located...
30 CFR 75.1107-11 - Extinguishing agents; requirements on mining equipment employed in low coal.
Code of Federal Regulations, 2011 CFR
2011-07-01
... equipment employed in low coal. 75.1107-11 Section 75.1107-11 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES... § 75.1107-11 Extinguishing agents; requirements on mining equipment employed in low coal. On mining...
30 CFR 75.1107-11 - Extinguishing agents; requirements on mining equipment employed in low coal.
Code of Federal Regulations, 2010 CFR
2010-07-01
... equipment employed in low coal. 75.1107-11 Section 75.1107-11 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES... § 75.1107-11 Extinguishing agents; requirements on mining equipment employed in low coal. On mining...
30 CFR 75.1107-11 - Extinguishing agents; requirements on mining equipment employed in low coal.
Code of Federal Regulations, 2014 CFR
2014-07-01
... equipment employed in low coal. 75.1107-11 Section 75.1107-11 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES... § 75.1107-11 Extinguishing agents; requirements on mining equipment employed in low coal. On mining...
30 CFR 75.1107-11 - Extinguishing agents; requirements on mining equipment employed in low coal.
Code of Federal Regulations, 2012 CFR
2012-07-01
... equipment employed in low coal. 75.1107-11 Section 75.1107-11 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES... § 75.1107-11 Extinguishing agents; requirements on mining equipment employed in low coal. On mining...
30 CFR 817.87 - Coal mine waste: Burning and burned waste utilization.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 3 2014-07-01 2014-07-01 false Coal mine waste: Burning and burned waste...-UNDERGROUND MINING ACTIVITIES § 817.87 Coal mine waste: Burning and burned waste utilization. (a) Coal mine... extinguishing operations. (b) No burning or unburned coal mine waste shall be removed from a permitted disposal...
30 CFR 817.87 - Coal mine waste: Burning and burned waste utilization.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 3 2013-07-01 2013-07-01 false Coal mine waste: Burning and burned waste...-UNDERGROUND MINING ACTIVITIES § 817.87 Coal mine waste: Burning and burned waste utilization. (a) Coal mine... extinguishing operations. (b) No burning or unburned coal mine waste shall be removed from a permitted disposal...
30 CFR 817.87 - Coal mine waste: Burning and burned waste utilization.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 3 2010-07-01 2010-07-01 false Coal mine waste: Burning and burned waste...-UNDERGROUND MINING ACTIVITIES § 817.87 Coal mine waste: Burning and burned waste utilization. (a) Coal mine... extinguishing operations. (b) No burning or unburned coal mine waste shall be removed from a permitted disposal...
30 CFR 817.87 - Coal mine waste: Burning and burned waste utilization.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 3 2012-07-01 2012-07-01 false Coal mine waste: Burning and burned waste...-UNDERGROUND MINING ACTIVITIES § 817.87 Coal mine waste: Burning and burned waste utilization. (a) Coal mine... extinguishing operations. (b) No burning or unburned coal mine waste shall be removed from a permitted disposal...
30 CFR 817.87 - Coal mine waste: Burning and burned waste utilization.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 3 2011-07-01 2011-07-01 false Coal mine waste: Burning and burned waste...-UNDERGROUND MINING ACTIVITIES § 817.87 Coal mine waste: Burning and burned waste utilization. (a) Coal mine... extinguishing operations. (b) No burning or unburned coal mine waste shall be removed from a permitted disposal...
NASA Astrophysics Data System (ADS)
Efremenko, Vladimir; Belyaevsky, Roman; Skrebneva, Evgeniya
2017-11-01
In article the analysis of electric power consumption and problems of power saving on coal mines are considered. Nowadays the share of conditionally constant costs of electric power for providing safe working conditions underground on coal mines is big. Therefore, the power efficiency of underground coal mining depends on electric power expense of the main technological processes and size of conditionally constant costs. The important direction of increase of power efficiency of coal mining is forecasting of a power consumption and monitoring of electric power expense. One of the main approaches to reducing of electric power costs is increase in accuracy of the enterprise demand in the wholesale electric power market. It is offered to use artificial neural networks to forecasting of day-ahead power consumption with hourly breakdown. At the same time use of neural and indistinct (hybrid) systems on the principles of fuzzy logic, neural networks and genetic algorithms is more preferable. This model allows to do exact short-term forecasts at a small array of input data. A set of the input parameters characterizing mining-and-geological and technological features of the enterprise is offered.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Curtis, C.W.; Chander, S.; Gutterman, C.
Liquefaction experiments were undertaken using subbituminous Black Thunder mine coal to observe the effects of aqueous SO{sub 2} coal beneficiation and the introduction of various coal swelling solvents and catalyst precursors. Aqueous SO{sub 2} beneficiation of Black Thunder coal removed alkali metals and alkaline earth metals, increased the sulfur content and increased the catalytic liquefaction conversion to THF solubles compared to untreated Black Thunder coal. The liquefaction solvent had varying effects on coal conversion, depending upon the type of solvent added. The hydrogen donor solvent, dihydroanthracene, was most effective, while a coal-derived Wilsonville solvent promoted more coal conversion than didmore » relatively inert 1-methylnaphthalene. Swelling of coal with hydrogen bonding solvents tetrahydrofuran (THF), isopropanol, and methanol, prior to reaction resulted in increased noncatalytic conversion of both untreated and SO{sub 2} treated Black Thunder coals, while dimethylsulfoxide (DMSO), which was absorbed more into the coal than any other swelling solvent, was detrimental to coal conversion. Swelling of SO{sub 2} treated coal before liquefaction resulted in the highest coal conversions; however, the untreated coal showed the most improvements in catalytic reactions when swelled in either THF, isopropanol, or methanol prior to liquefaction. The aprotic solvent DMSO was detrimental to coal conversion.« less
Locating and defining underground goaf caused by coal mining from space-borne SAR interferometry
NASA Astrophysics Data System (ADS)
Yang, Zefa; Li, Zhiwei; Zhu, Jianjun; Yi, Huiwei; Feng, Guangcai; Hu, Jun; Wu, Lixin; Preusse, Alex; Wang, Yunjia; Papst, Markus
2018-01-01
It is crucial to locate underground goafs (i.e., mined-out areas) resulting from coal mining and define their spatial dimensions for effectively controlling the induced damages and geohazards. Traditional geophysical techniques for locating and defining underground goafs, however, are ground-based, labour-consuming and costly. This paper presents a novel space-based method for locating and defining the underground goaf caused by coal extraction using Interferometric Synthetic Aperture Radar (InSAR) techniques. As the coal mining-induced goaf is often a cuboid-shaped void and eight critical geometric parameters (i.e., length, width, height, inclined angle, azimuth angle, mining depth, and two central geodetic coordinates) are capable of locating and defining this underground space, the proposed method reduces to determine the eight geometric parameters from InSAR observations. Therefore, it first applies the Probability Integral Method (PIM), a widely used model for mining-induced deformation prediction, to construct a functional relationship between the eight geometric parameters and the InSAR-derived surface deformation. Next, the method estimates these geometric parameters from the InSAR-derived deformation observations using a hybrid simulated annealing and genetic algorithm. Finally, the proposed method was tested with both simulated and two real data sets. The results demonstrate that the estimated geometric parameters of the goafs are accurate and compatible overall, with averaged relative errors of approximately 2.1% and 8.1% being observed for the simulated and the real data experiments, respectively. Owing to the advantages of the InSAR observations, the proposed method provides a non-contact, convenient and practical method for economically locating and defining underground goafs in a large spatial area from space.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Walton, D.; Ingham, W.; Kauffman, P.
With the rapid developments taking place in coal mining technology and due to high investment costs, optimization of the structure of underground coal mines is crucial to the success of the mining project. The structure of a mine, once it is developed, cannot be readily changed and has a decisive influence on the productivity, safety, economics, and production capacity of the mine. The Department of Energy desires to ensure that the resource characterization and planning activity for underground coal mining will focus on those areas that offer the most promise of being advanced. Thus, this project was undertaken by Managementmore » Engineers Incorporated to determine the status in all aspects of the resource characterization and planning activities for underground coal mining as presently performed in the industry. The study team conducted a comprehensive computerized literature search and reviewed the results. From this a selection of the particularly relevant sources were annotated and a reference list was prepared, catalogued by resource characterization and mine planning activity. From this data, and discussions with industry representatives, academia, and research groups, private and federal, an assessment and evaluation was made of the state-of-the-art of each element in the resource characterization and mine planning process. The results of this analysis lead to the identifcation of areas requiring research and, specifically, those areas where DOE research efforts may be focused.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
In the fall of 1972, the Laramie Energy Research Center initiated an in situ coal gasification experiment in Hanna, Wyoming. The objective was to test the feasibility of underground gasification in a deep, thick seam of western subbituminous coal and, if feasible, to maximize gas heating value while sustaining stable gas production rates and achieving a high coal utilization efficiency. The coal seam was ignited on March 28, 1973, in a 30-foot seam 400 feet deep. The ''burn'' was maintained for a year, until March 22, 1974, when air injection was stopped. The combustion zone was extinguished by the naturalmore » influx of seam water in approximately three months. This report discusses the environmental inpacts of this program on the area and provides details of the program. 13 refs., 7 figs., 11 tabs.« less
Code of Federal Regulations, 2010 CFR
2010-07-01
... Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES Surface Installations § 77.207 Illumination. Illumination sufficient to provide safe working conditions shall be...
30 CFR 75.501-1 - Coal seams above the water table.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Coal seams above the water table. 75.501-1 Section 75.501-1 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Electrical Equipment-General § 75.501...
30 CFR 75.501-1 - Coal seams above the water table.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Coal seams above the water table. 75.501-1 Section 75.501-1 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Electrical Equipment-General § 75.501...
30 CFR 49.40 - Requirements for large coal mines.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Requirements for large coal mines. 49.40 Section 49.40 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR EDUCATION AND TRAINING MINE RESCUE TEAMS Mine Rescue Teams for Underground Coal Mines § 49.40 Requirements for large coal...
30 CFR 49.40 - Requirements for large coal mines.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Requirements for large coal mines. 49.40 Section 49.40 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR EDUCATION AND TRAINING MINE RESCUE TEAMS Mine Rescue Teams for Underground Coal Mines § 49.40 Requirements for large coal...
30 CFR 75.501-1 - Coal seams above the water table.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Coal seams above the water table. 75.501-1 Section 75.501-1 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Electrical Equipment-General § 75.501...
30 CFR 75.501-1 - Coal seams above the water table.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Coal seams above the water table. 75.501-1 Section 75.501-1 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Electrical Equipment-General § 75.501...
30 CFR 49.30 - Requirements for small coal mines.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Requirements for small coal mines. 49.30 Section 49.30 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR EDUCATION AND TRAINING MINE RESCUE TEAMS Mine Rescue Teams for Underground Coal Mines § 49.30 Requirements for small coal...
30 CFR 49.40 - Requirements for large coal mines.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Requirements for large coal mines. 49.40 Section 49.40 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR EDUCATION AND TRAINING MINE RESCUE TEAMS Mine Rescue Teams for Underground Coal Mines § 49.40 Requirements for large coal...
30 CFR 49.30 - Requirements for small coal mines.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Requirements for small coal mines. 49.30 Section 49.30 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR EDUCATION AND TRAINING MINE RESCUE TEAMS Mine Rescue Teams for Underground Coal Mines § 49.30 Requirements for small coal...
30 CFR 49.40 - Requirements for large coal mines.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Requirements for large coal mines. 49.40 Section 49.40 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR EDUCATION AND TRAINING MINE RESCUE TEAMS Mine Rescue Teams for Underground Coal Mines § 49.40 Requirements for large coal...
30 CFR 75.501-1 - Coal seams above the water table.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Coal seams above the water table. 75.501-1 Section 75.501-1 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Electrical Equipment-General § 75.501...
30 CFR 49.40 - Requirements for large coal mines.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Requirements for large coal mines. 49.40 Section 49.40 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR EDUCATION AND TRAINING MINE RESCUE TEAMS Mine Rescue Teams for Underground Coal Mines § 49.40 Requirements for large coal...
30 CFR 49.30 - Requirements for small coal mines.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Requirements for small coal mines. 49.30 Section 49.30 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR EDUCATION AND TRAINING MINE RESCUE TEAMS Mine Rescue Teams for Underground Coal Mines § 49.30 Requirements for small coal...
30 CFR 49.30 - Requirements for small coal mines.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Requirements for small coal mines. 49.30 Section 49.30 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR EDUCATION AND TRAINING MINE RESCUE TEAMS Mine Rescue Teams for Underground Coal Mines § 49.30 Requirements for small coal...
30 CFR 49.30 - Requirements for small coal mines.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Requirements for small coal mines. 49.30 Section 49.30 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR EDUCATION AND TRAINING MINE RESCUE TEAMS Mine Rescue Teams for Underground Coal Mines § 49.30 Requirements for small coal...
Evaluating the feasibility of underground coal gasification in Thailand
DOE Office of Scientific and Technical Information (OSTI.GOV)
Young, B.C.; Harju, J.A.; Schmit, C.R.
Underground coal gasification (UCG) is a clean coal technology that converts in situ coal into a low- to medium-grade product gas without the added expense of mining and reclamation. Potential candidates for UCG are those coal resources that are not economically recoverable or that are otherwise unacceptable for conventional coal utilization processes. The Energy and Environmental Research Center (EERC), through the sponsorship of the US Trade and Development Agency and in collaboration with the Electricity Generating Authority of Thailand (EGAT), is undertaking a feasibility study for the application of UCG in the Krabi coal mining area, 620 miles south ofmore » Bangkok in Thailand. The EERC`s objective for this project is to determine the technical, environmental, and economic feasibility of demonstrating and commercializing UCG at a selected site in the Krabi coal mining area. This paper addresses the preliminary developments and ongoing strategy for evaluating the selected UCG site. The technical, environmental, and economic factors for successful UCG operation are discussed, as well as the strategic issues pertaining to future energy expansion in southern Thailand.« less
30 CFR 75.816 - Guarding of cables.
Code of Federal Regulations, 2010 CFR
2010-07-01
... MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Underground High-Voltage Distribution High-Voltage Longwalls § 75.816 Guarding of cables. (a) High-voltage cables must be guarded at the following locations...
Evidence of Human Health Impacts from Uncontrolled Coal Fires in Jharia, India
NASA Astrophysics Data System (ADS)
Dhar, U.; Balogun, A. H.; Finkelman, R.; Chakraborty, S.; Olanipekun, O.; Shaikh, W. A.
2017-12-01
Uncontrolled coal fires and burning coal waste piles have been reported from dozens of countries. These fires can be caused by spontaneous combustion, sparks from machinery, lightning strikes, grass or forest fires, or intentionally. Both underground and surface coal fires mobilize potentially toxic elements such as sulfur, arsenic, selenium, fluorine, lead, and mercury as well as dangerous organic compounds such as benzene, toluene, xylene, ethylbenzene and deadly gases such as CO2 and CO. Despite the serious health problems that can be caused by uncontrolled coal fires it is rather surprising that there has been so little research and documentation of their health impacts. Underground coal fires in the Jharia region of India where more than a million people reside, have been burning for 100 years. Numerous villages exist above the underground fires exposing the residents daily to dangerous emissions. Local residents near the fire affected areas do their daily chores without concern about the intensity of nearby fires. During winter children enjoy the heat of the coal fires oblivious to the potentially harmful emissions. To determine if these uncontrolled coal fires have caused health problems we developed a brief questionnaire on general health indices and administered it to residents of the Jharia region. Sixty responses were obtained from residents of two villages, one proximal to the coal fires and one about 5 miles away from the fires. The responses were statistically analyzed using SAS 9.4. It was observed that at a significance level of 5%, villagers who lived more than 5 miles away from the fires had a 98.3% decreased odds of having undesirable health outcomes. This brief survey indicates the risk posed by underground coal fires and how it contributes to the undesirable health impacts. What remains is to determine the specific health issues, what components of the emissions cause the health problems, and what can be done to minimize these problems. Collaboration between geoscientists and public health researchers are essential to assess complex geohealth issues such as those that may be caused by uncontrolled coal fires. This type of multidisciplinary collaboration must be maintained and expanded to include engineers, social scientists, and others to help minimize or avoid these problems.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Meiers, R.J.; Golden, D.; Gray, R.
1995-12-31
Indianapolis Power and Light Company (IPL) began researching the use of fluid placement techniques of the fixated scrubber sludge (FSS) to reduce surface subsidence from underground coal mines to develop an economic alternative to low strength concrete grout. Abandoned underground coal mines surround property adjacent to IPL`s coal combustion by-product (CCBP) landfill at the Petersburg Generating Station. Landfill expansion into these areas is in question because of the high potential for sinkhole subsidence to develop. Sinkholes manifesting at the surface would put the integrity of a liner or runoff pond containment structure for a CCBP disposal facility at risk. Themore » fluid placement techniques of the FSS as a subsidence abatement technology was demonstrated during an eight week period in September, October, and November 1994 at the Petersburg Generating Station. The success of this technology will be determined by the percentage of the mine void filled, strength of the FSS placed, and the overall effects on the hydrogeologic environment. The complete report for this project will be finalized in early 1996.« less
Simulation and Measurement of Medium-Frequency Signals Coupling From a Line to a Loop Antenna
Damiano, Nicholas W.; Li, Jingcheng; Zhou, Chenming; Brocker, Donovan E.; Qin, Yifeng; Werner, Douglas H.; Werner, Pingjuan L.
2016-01-01
The underground-mining environment can affect radio-signal propagation in various ways. Understanding these effects is especially critical in evaluating communications systems used during normal mining operations and during mine emergencies. One of these types of communications systems relies on medium-frequency (MF) radio frequencies. This paper presents the simulation and measurement results of recent National Institute for Occupational Safety and Health (NIOSH) research aimed at investigating MF coupling between a transmission line (TL) and a loop antenna in an underground coal mine. Two different types of measurements were completed: 1) line-current distribution and 2) line-to-antenna coupling. Measurements were taken underground in an experimental coal mine and on a specially designed surface test area. The results of these tests are characterized by current along a TL and voltage induced in the loop from a line. This paper concludes with a discussion of issues for MF TLs. These include electromagnetic fields at the ends of the TL, connection of the ends of the TL, the effect of other conductors underground, and the proximity of coal or earth. These results could help operators by providing examples of these challenges that may be experienced underground and a method by which to measure voltage induced by a line. PMID:27784954
30 CFR 77.1007 - Drilling; general.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES Ground... each shift by a competent person. Equipment defects affecting safety shall be reported. (b) Equipment...
30 CFR 77.808 - Disconnecting devices.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES Surface High-Voltage Distribution § 77.808 Disconnecting devices. Disconnecting devices shall be installed at the...
30 CFR 75.808 - Disconnecting devices.
Code of Federal Regulations, 2010 CFR
2010-07-01
... MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Underground High-Voltage Distribution § 75.808... branch lines in high-voltage circuits and equipped or designed in such a manner that it can be determined...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Goodman, P.S.
The report examines the feasibility of employee-assistance plans for the coal industry. Three issues are examined in detail. First, the prevalence of off-the-job factors such as alcoholism, drug abuse, and marital problems are examined in a sample of miners from the eastern, midwestern, and western underground coalfields. Then, data are presented from examination of the link between these off-the-job factors and behaviors critical to the mines such as absenteeism and turnover. Lastly, the effectiveness of the major employee-assistance program in underground coal mining - the HELP Program was examined. The report contains recommendations on whether coal-mining companies should implement thesemore » programs and how these programs should be designed.« less
30 CFR 77.1001 - Stripping; loose material.
Code of Federal Regulations, 2010 CFR
2010-07-01
....1001 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES... angle of repose, or barriers, baffle boards, screens, or other devices be provided that afford...
30 CFR 870.11 - Applicability.
Code of Federal Regulations, 2014 CFR
2014-07-01
... LAND RECLAMATION ABANDONED MINE RECLAMATION FUND-FEE COLLECTION AND COAL PRODUCTION REPORTING § 870.11 Applicability. The regulations in this part apply to all surface and underground coal mining operations except... him; (b) The extraction of coal as an incidental part of Federal, State, or local government-financed...
30 CFR 870.11 - Applicability.
Code of Federal Regulations, 2012 CFR
2012-07-01
... LAND RECLAMATION ABANDONED MINE RECLAMATION FUND-FEE COLLECTION AND COAL PRODUCTION REPORTING § 870.11 Applicability. The regulations in this part apply to all surface and underground coal mining operations except... him; (b) The extraction of coal as an incidental part of Federal, State, or local government-financed...
30 CFR 870.11 - Applicability.
Code of Federal Regulations, 2013 CFR
2013-07-01
... LAND RECLAMATION ABANDONED MINE RECLAMATION FUND-FEE COLLECTION AND COAL PRODUCTION REPORTING § 870.11 Applicability. The regulations in this part apply to all surface and underground coal mining operations except... him; (b) The extraction of coal as an incidental part of Federal, State, or local government-financed...
30 CFR 870.11 - Applicability.
Code of Federal Regulations, 2010 CFR
2010-07-01
... LAND RECLAMATION ABANDONED MINE RECLAMATION FUND-FEE COLLECTION AND COAL PRODUCTION REPORTING § 870.11 Applicability. The regulations in this part apply to all surface and underground coal mining operations except... him; (b) The extraction of coal as an incidental part of Federal, State, or local government-financed...
30 CFR 870.11 - Applicability.
Code of Federal Regulations, 2011 CFR
2011-07-01
... LAND RECLAMATION ABANDONED MINE RECLAMATION FUND-FEE COLLECTION AND COAL PRODUCTION REPORTING § 870.11 Applicability. The regulations in this part apply to all surface and underground coal mining operations except... him; (b) The extraction of coal as an incidental part of Federal, State, or local government-financed...
30 CFR 77.1434 - Retirement criteria.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES Personnel... corrosion; (e) Distortion of the rope structure; (f) Heat damage from any source; (g) Diameter reduction due...
30 CFR 77.403-2 - Incorporation by reference.
Code of Federal Regulations, 2011 CFR
2011-07-01
....403-2 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL... been prepared by organizations other than the Mine Safety and Health Administration (MSHA), are hereby...
30 CFR 77.403-2 - Incorporation by reference.
Code of Federal Regulations, 2010 CFR
2010-07-01
....403-2 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL... been prepared by organizations other than the Mine Safety and Health Administration (MSHA), are hereby...
30 CFR 77.100 - Certified person.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES Qualified and... independent contractor shall make an application which satisfactorily shows that each such person has had at...
30 CFR 77.1437 - End attachment retermination.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 77.1437 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL... at an attachment; (b) Improper installation of an attachment; (c) Slippage at an attachment; or (d...
30 CFR 77.512 - Inspection and cover plates.
Code of Federal Regulations, 2010 CFR
2010-07-01
....512 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES... equipment shall be kept in place at all times except during testing or repairs. ...
Geological and Rock Mechanics Perspectives for Underground Coal Gasification in India
NASA Astrophysics Data System (ADS)
Singh, Ajay K.; Singh, Rajendra
2017-07-01
The geological resources of coal in India are more than 308 billion tonnes upto a depth of 1200 m, out of which proved reserve has been reported at around 130 billion tonnes. There is an increasing requirement to increase the energy extraction efficiency from coal as the developmental prospects of India increase. Underground coal gasification (UCG) is a potential mechanism which may be utilized for extraction of deep-seated coal reserves. Some previous studies suggest that lignites from Gujarat and Rajasthan, along with tertiary coals from northeastern India can be useful from the point of view of UCG. We discuss some geological literature available for these areas. Coming to the rock mechanics perspectives, during UCG the rock temperature is considerable high. At this temperature, most empirical models of rock mechanics may not be applied. In this situation, the challenges for numerical modelling of UCG sites increases manifold. We discuss some of the important modelling geomechanical issues related to UCG in India.
Krech, Eugen; Selinski, Silvia; Blaszkewicz, Meinolf; Bürger, Hannah; Kadhum, Thura; Hengstler, Jan G; Truss, Michael C; Golka, Klaus
2017-01-01
This study was performed to investigate the frequency of bladder cancer in patients with an occupational history such as underground hard coal mining and/or painting after the structural change in the local industry. A total of 206 patients with bladder cancer and 207 controls were enlisted regarding occupational and nonoccupational bladder cancer risk factors by questionnaire. The phase II enzymes N-acetyltransferase 2 (NAT2), glutathione S-transferases M1 (GSTM1), and T1 (GSTT1) and the single nucleotide polymorphism (SNP) rs11892031[A/C] reported to be associated with bladder cancer in genome-wide association studies were genotyped. The bladder cancer risk in varnishers and underground hard coal miners was increased as previously shown in a study in this area performed in the 1980s. The occupation of a car mechanic was associated with a significantly elevated bladder cancer risk and higher in the case of underground hard coal miners even though the mine was closed in 1987. The frequency of GSTM1 negative genotype was comparable in cases and controls (53% versus 54%). In the case of NAT2, the slow NAT2 genotype was more frequent (62% versus 58%) and ultra-slow NAT2 genotype (NAT2*6A and/or *7B alleles only) was 23% versus 15%. An occupational history of a varnisher or an underground hard coal miner remains a risk factor for bladder cancer occurrence. Data indicate that in the case of bladder cancer, GSTM1 is a susceptibility factor related to environmental and/or occupational exposure.
Proceedings of second annual underground coal gasification symposium
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shuck, L Z
The Second Annual Underground Coal Gasification Symposium was sponsored by the Morgantown Energy Research Center of the US Energy Research and Development Administration and held at Morgantown, WV, August 10-12, 1976. Fifty papers of the proceedings have been entered individually into EDB and ERA. While the majority of the contribution involved ERDA's own work in this area, there were several papers from universities, state organizations, (industrial, engineering or utility companies) and a few from foreign countries. (LTN)
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-02
... Extension of Existing Information Collection; Ground Control for Surface Coal Mines and Surface Work Areas of Underground Coal Mines AGENCY: Mine Safety and Health Administration, Labor. ACTION: Request for... inspections and investigations in coal or other mines shall be made each year for the purposes of, among other...
The effect of coal-bed methane water on spearmint and peppermint
USDA-ARS?s Scientific Manuscript database
Coal bed methane (CBM) is extracted from underground coal seams, flooded with water. In order to reduce the pressure and release the methane, the trapped water needs to be pumped out. The resulting ‘waste water’ is known as coal-bed methane water (CBMW). Major concerns with the use of CBMW are the h...
30 CFR 75.400 - Accumulation of combustible materials.
Code of Federal Regulations, 2014 CFR
2014-07-01
... SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Combustible Materials and Rock... rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be...
30 CFR 75.400 - Accumulation of combustible materials.
Code of Federal Regulations, 2011 CFR
2011-07-01
... SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Combustible Materials and Rock... rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be...
30 CFR 75.400 - Accumulation of combustible materials.
Code of Federal Regulations, 2010 CFR
2010-07-01
... SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Combustible Materials and Rock... rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be...
30 CFR 75.400 - Accumulation of combustible materials.
Code of Federal Regulations, 2012 CFR
2012-07-01
... SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Combustible Materials and Rock... rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be...
30 CFR 75.400 - Accumulation of combustible materials.
Code of Federal Regulations, 2013 CFR
2013-07-01
... SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Combustible Materials and Rock... rock-dusted surfaces, loose coal, and other combustible materials, shall be cleaned up and not be...
30 CFR 77.1433 - Examinations.
Code of Federal Regulations, 2011 CFR
2011-07-01
... SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES Personnel Hoisting... be made at stress points, including the area near attachments, where the rope rests on sheaves, where...
30 CFR 77.1433 - Examinations.
Code of Federal Regulations, 2010 CFR
2010-07-01
... SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES Personnel Hoisting... be made at stress points, including the area near attachments, where the rope rests on sheaves, where...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Scope. 75.200 Section 75.200 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY... controlling roof, face and ribs, including coal or rock bursts, in underground coal mines. Roof control...
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Scope. 75.200 Section 75.200 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY... controlling roof, face and ribs, including coal or rock bursts, in underground coal mines. Roof control...
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Scope. 75.200 Section 75.200 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY... controlling roof, face and ribs, including coal or rock bursts, in underground coal mines. Roof control...
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Scope. 75.200 Section 75.200 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY... controlling roof, face and ribs, including coal or rock bursts, in underground coal mines. Roof control...
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Scope. 75.200 Section 75.200 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY... controlling roof, face and ribs, including coal or rock bursts, in underground coal mines. Roof control...
30 CFR 77.1905 - Hoist safeguards; general.
Code of Federal Regulations, 2010 CFR
2010-07-01
....1905 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES... when fully loaded. (b) When persons are transported by a hoist, a second person familiar with and...
30 CFR 71.209 - Respirable dust samples; transmission by operator.
Code of Federal Regulations, 2012 CFR
2012-07-01
... operator. 71.209 Section 71.209 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES Sampling Procedures § 71.209 Respirable dust samples; transmission by...
30 CFR 71.209 - Respirable dust samples; transmission by operator.
Code of Federal Regulations, 2013 CFR
2013-07-01
... operator. 71.209 Section 71.209 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES Sampling Procedures § 71.209 Respirable dust samples; transmission by...
30 CFR 71.209 - Respirable dust samples; transmission by operator.
Code of Federal Regulations, 2014 CFR
2014-07-01
... operator. 71.209 Section 71.209 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES Sampling Procedures § 71.209 Respirable dust samples; transmission by...
30 CFR 75.381 - Escapeways; anthracite mines.
Code of Federal Regulations, 2010 CFR
2010-07-01
....381 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Ventilation § 75.381 Escapeways; anthracite... by 5 feet high. If the pitch or thickness of the coal seam does not permit these dimensions to be...
30 CFR 77.1800 - Cutout switches.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES Trolley... be provided with cutout switches at intervals of not more than 2,000 feet and near the beginning of...
30 CFR 77.1906 - Hoists; daily inspection.
Code of Federal Regulations, 2011 CFR
2011-07-01
....1906 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES... shall be run by the hoist operator through one complete cycle of operation before any person is...
Code of Federal Regulations, 2014 CFR
2014-07-01
... SAFETY STANDARDS-UNDERGROUND COAL MINES Underground Low- and Medium-Voltage Alternating Current Circuits... from resistance grounded systems separate connections shall be used when practicable. ...
Code of Federal Regulations, 2013 CFR
2013-07-01
... SAFETY STANDARDS-UNDERGROUND COAL MINES Underground Low- and Medium-Voltage Alternating Current Circuits... from resistance grounded systems separate connections shall be used when practicable. ...
Code of Federal Regulations, 2012 CFR
2012-07-01
... SAFETY STANDARDS-UNDERGROUND COAL MINES Underground Low- and Medium-Voltage Alternating Current Circuits... from resistance grounded systems separate connections shall be used when practicable. ...
NASA Astrophysics Data System (ADS)
Li-bo, Dang; Jia-chun, Wu; Yue-xing, Liu; Yuan, Chang; Bin, Peng
2017-04-01
Underground coal fire (UCF) is serious in Xinjiang region of China. In order to deal with this problem efficiently, a UCF monitoring System, which is based on the use of wireless communication technology and remote sensing images, was designed and implemented by Xinjiang Coal Fire Fighting Bureau. This system consists of three parts, i.e., the data collecting unit, the data processing unit and the data output unit. For the data collecting unit, temperature sensors and gas sensors were put together on the sites with depth of 1.5 meter from the surface of coal fire zone. Information on these sites' temperature and gas was transferred immediately to the data processing unit. The processing unit was developed by coding based on GIS software. Generally, the processed datum were saved in the computer by table format, which can be displayed on the screen as the curve. Remote sensing image for each coal fire was saved in this system as the background for each monitoring site. From the monitoring data, the changes of the coal fires were displayed directly. And it provides a solid basis for analyzing the status of coal combustion of coal fire, the gas emission and possible dominant direction of coal fire propagation, which is helpful for making-decision of coal fire extinction.
Wireless device for activation of an underground shock wave absorber
NASA Astrophysics Data System (ADS)
Chikhradze, M.; Akhvlediani, I.; Bochorishvili, N.; Mataradze, E.
2011-10-01
The paper describes the mechanism and design of the wireless device for activation of energy absorber for localization of blast energy in underground openings. The statistics shows that the greatest share of accidents with fatal results associate with explosions in coal mines due to aero-methane and/or air-coal media explosion. The other significant problem is terrorist or accidental explosions in underground structures. At present there are different protective systems to reduce the blast energy. One of the main parts of protective Systems is blast Identification and Registration Module. The works conducted at G. Tsulukidze Mining Institute of Georgia enabled to construct the wireless system of explosion detection and mitigation of shock waves. The system is based on the constant control on overpressure. The experimental research continues to fulfill the system based on both threats, on the constant control on overpressure and flame parameters, especially in underground structures and coal mines. Reaching the threshold value of any of those parameters, the system immediately starts the activation. The absorber contains a pyrotechnic device ensuring the discharge of dispersed water. The operational parameters of wireless device and activation mechanisms of pyrotechnic element of shock wave absorber are discussed in the paper.
Serum angiotensin-converting enzyme is elevated in association with underground coal mining
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thompson, A.B.; Cale, W.F.; Lapp, N.L.
1991-10-01
Serum angiotensin-converting enzyme activity (SACE) and lysozyme activity were measured in a group of 40 underground coal miners and two control groups, 20 subjects with sarcoidosis and 15 normal non-dust-exposed volunteers. The miners were grouped first according to whether they had recent exposure (still actively mining or retired three years or less prior to measurement) or temporally more distant exposure (retired more than three years prior to measurement). Secondly, they were grouped as to whether or not they had coal workers' pneumoconiosis (CWP). The subjects with sarcoidosis were grouped according to disease activity. As expected, the subjects with active sarcoidosismore » had elevated SACE activity compared with normal subjects. The coal miners as a group did not have elevation of their SACE activity. However, the coal miners with recent exposure had elevated SACE activity (57.1 {plus minus} 3.9 U/ml) compared with normal controls (43.8 {plus minus} 1.5 U/ml, p = 0.007). The SACE activity in miners without recent exposure was not elevated (39.8 {plus minus} 1.3 U/ml) compared with the normal controls. No increase in SACE activity was found when the miners were grouped according to the presence or absence of CWP. In contrast, the miners' serum lysozyme activity was not elevated. Since alveolar macrophages are a potential source of SACE, elevation of SACE activity in underground coal miners may reflect alveolar macrophage activation caused by increased pulmonary mixed coal mine dust burden. Furthermore, since both SACE and serum lysozyme are elevated in association with silicosis, these findings may confirm that the macrophage responses to inhaled silica and coal dust differ.« less
30 CFR 71.220 - Status change reports.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES Sampling... status of the mine or designated work position to the MSHA District Office or to any other MSHA office...
30 CFR 71.220 - Status change reports.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES Sampling Procedures § 71.220 Status change reports. (a) If there is a change in operational status that affects the...
30 CFR 71.208 - Bimonthly sampling; designated work positions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Bimonthly sampling; designated work positions... COAL MINE SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES Sampling Procedures § 71.208 Bimonthly sampling; designated work positions. (a) Each...
30 CFR 77.1436 - Drum end attachment.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES Personnel... making one full turn around the shaft, if the drum is fixed to the shaft; or (3) By properly assembled...
30 CFR 77.502-2 - Electric equipment; frequency of examination and testing.
Code of Federal Regulations, 2010 CFR
2010-07-01
... and testing. 77.502-2 Section 77.502-2 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES Electrical Equipment-General § 77.502-2 Electric equipment...
Code of Federal Regulations, 2010 CFR
2010-07-01
... SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES General § 77.1 Scope. This..., pursuant to section 101(i) of the Federal Mine Safety and Health Act of 1977. [36 FR 9364, May 22, 1971, as...
30 CFR 77.209 - Surge and storage piles.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES Surface... a reclaiming area or in any other area at or near a surge or storage pile where the reclaiming...
30 CFR 77.1402-1 - Maximum load; posting.
Code of Federal Regulations, 2010 CFR
2010-07-01
....1402-1 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL... number of men permitted to ride on each hoist or elevator at one time; this limit shall be posted on each...
30 CFR 77.1708 - Safety program; instruction of persons employed at the mine.
Code of Federal Regulations, 2010 CFR
2010-07-01
... at the mine. 77.1708 Section 77.1708 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES Miscellaneous § 77.1708 Safety program; instruction of persons...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-14
... Request; Coal Mine Rescue Teams; Arrangements for Emergency Medical Assistance and Transportation for... Part 49, Mine Rescue Teams, Subpart B--Mine Rescue Teams for Underground Coal Mines, sets standards related to the availability of mine rescue teams; alternate mine rescue capability for small and remote...
30 CFR 77.213 - Draw-off tunnel escapeways.
Code of Federal Regulations, 2011 CFR
2011-07-01
....213 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES... horizontal it shall be equipped with a ladder which runs the full length of the inclined portion of the...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-19
... surface estate, the mining method or methods, and any comparable sales data on similar coal lands. The... offered is limited to coal recoverable by underground mining methods. The Federal coal is in the lands... would be rejected or denied. The Federal coal reserves would be bypassed. Proprietary data marked as...
Sensing underground coal gasification by ground penetrating radar
NASA Astrophysics Data System (ADS)
Kotyrba, Andrzej; Stańczyk, Krzysztof
2017-12-01
The paper describes the results of research on the applicability of the ground penetrating radar (GPR) method for remote sensing and monitoring of the underground coal gasification (UCG) processes. The gasification of coal in a bed entails various technological problems and poses risks to the environment. Therefore, in parallel with research on coal gasification technologies, it is necessary to develop techniques for remote sensing of the process environment. One such technique may be the radar method, which allows imaging of regions of mass loss (voids, fissures) in coal during and after carrying out a gasification process in the bed. The paper describes two research experiments. The first one was carried out on a large-scale model constructed on the surface. It simulated a coal seam in natural geological conditions. A second experiment was performed in a shallow coal deposit maintained in a disused mine and kept accessible for research purposes. Tests performed in the laboratory and in situ conditions showed that the method provides valuable data for assessing and monitoring gasification surfaces in the UCG processes. The advantage of the GPR method is its high resolution and the possibility of determining the spatial shape of various zones and forms created in the coal by the gasification process.
Xu, Jingjing; Yang, Wei; Zhang, Linyuan; Han, Ruisong; Shao, Xiaotao
2015-01-01
In this paper, a wireless sensor network (WSN) technology adapted to underground channel conditions is developed, which has important theoretical and practical value for safety monitoring in underground coal mines. According to the characteristics that the space, time and frequency resources of underground tunnel are open, it is proposed to constitute wireless sensor nodes based on multicarrier code division multiple access (MC-CDMA) to make full use of these resources. To improve the wireless transmission performance of source sensor nodes, it is also proposed to utilize cooperative sensors with good channel conditions from the sink node to assist source sensors with poor channel conditions. Moreover, the total power of the source sensor and its cooperative sensors is allocated on the basis of their channel conditions to increase the energy efficiency of the WSN. To solve the problem that multiple access interference (MAI) arises when multiple source sensors transmit monitoring information simultaneously, a kind of multi-sensor detection (MSD) algorithm with particle swarm optimization (PSO), namely D-PSO, is proposed for the time-frequency coded cooperative MC-CDMA WSN. Simulation results show that the average bit error rate (BER) performance of the proposed WSN in an underground coal mine is improved significantly by using wireless sensor nodes based on MC-CDMA, adopting time-frequency coded cooperative transmission and D-PSO algorithm with particle swarm optimization. PMID:26343660
Xu, Jingjing; Yang, Wei; Zhang, Linyuan; Han, Ruisong; Shao, Xiaotao
2015-08-27
In this paper, a wireless sensor network (WSN) technology adapted to underground channel conditions is developed, which has important theoretical and practical value for safety monitoring in underground coal mines. According to the characteristics that the space, time and frequency resources of underground tunnel are open, it is proposed to constitute wireless sensor nodes based on multicarrier code division multiple access (MC-CDMA) to make full use of these resources. To improve the wireless transmission performance of source sensor nodes, it is also proposed to utilize cooperative sensors with good channel conditions from the sink node to assist source sensors with poor channel conditions. Moreover, the total power of the source sensor and its cooperative sensors is allocated on the basis of their channel conditions to increase the energy efficiency of the WSN. To solve the problem that multiple access interference (MAI) arises when multiple source sensors transmit monitoring information simultaneously, a kind of multi-sensor detection (MSD) algorithm with particle swarm optimization (PSO), namely D-PSO, is proposed for the time-frequency coded cooperative MC-CDMA WSN. Simulation results show that the average bit error rate (BER) performance of the proposed WSN in an underground coal mine is improved significantly by using wireless sensor nodes based on MC-CDMA, adopting time-frequency coded cooperative transmission and D-PSO algorithm with particle swarm optimization.
Unstable ground in western North Dakota
Trimble, Donald E.
1979-01-01
Unstable ground in western North Dakota is mainly the result of mass-wasting processes. The units most affected are mudstones, siltstones, and sandstones of the Fort Union Formation. Ground instability generally is indicated by landslides, soil slides, or subsidence. Landslides are mostly of the slump-earthflow type and are localized along the flanks of the high buttes in southwestern North Dakota, including HT (Black) Butte, Chalky Buttes, Sentinel Butte, and East and West Rainy Buttes, and along parts of the valleys of the Des Lacs, Missouri, Little Missouri, and Heart Rivers. Landslides are sparse elsewhere. Soil slides are common in the areas south and southwest of the maximum position of the Pleistocene glacial ice margin on slopes of 15 degrees or more, and have taken place on some slopes as gentle as five degrees. The weathered, exposed surface of the Fort Union Formation seems to be especially susceptible to soil slides. Soil slides constitute the major type of ground instability in southwestern North Dakota. Subsidence is of two types: (1) subsidence over old underground mine workings, and (2) subsidence over naturally ignited and burned underground coal beds. Major subsidence has taken place over old, underground workings near Beulah, Wilton, Lehigh, Haynes, and Belfield, and lesser subsidence near Scranton, and west and north of Bowman. Thickness of overburden above the coal in all these areas is believed to be less than 30 m (100 ft). Subsidence has not taken place over old underground workings along the Des Lacs and-Souris valleys northwest of Minot, where the thickness of overburden is more than 60 m (200 ft). Spectacular subsidence has occurred over a burning underground coal bed at Burning Coal Vein Park near the Little Missouri River, northwest of Amidon.
Code of Federal Regulations, 2010 CFR
2010-07-01
... SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES Safeguards for Mechanical Equipment § 77.406 Drive belts. (a) Drive belts shall not be shifted while in motion unless the...
30 CFR 75.1101-8 - Water sprinkler systems; arrangement of sprinklers.
Code of Federal Regulations, 2010 CFR
2010-07-01
... OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire... sprinklers functioning. (d) Each individual sprinkler shall be activated at a temperature of not less than...
NASA Astrophysics Data System (ADS)
Sharma, Surabhi; Mahajani, Sanjay M.
2017-07-01
This paper presents the summary of the work performed over the last decade, at IIT Bombay by the UCG group. The overall objective is to determine the feasibility of a given coal for underground coal gasification and then determine the capacity of a single pair of well through modelling and simulation. It would help one to design a UCG facility for the desired rate of gas production. The simulator developed in this study seeks inputs on four important aspects: Kinetics of all the reactions under the conditions of interest, heat and mass transfer limitations, if any, the flow patterns inside the cavity and lastly the thermo-mechanical failure of the coal. Each of them requires detailed studies in laboratory. Indian Lignite from one of the reserves was chosen as a case study.
NASA Astrophysics Data System (ADS)
Korre, Anna; Andrianopoulos, Nondas; Durucan, Sevket
2015-04-01
Underground Coal Gasification (UCG) is an unconventional method for recovering energy from coal resources through in-situ thermo-chemical conversion to gas. In the core of the UCG lays the coal gasification process which involves the engineered injection of a blend of gasification agents into the coal resource and propagating its gasification. Athough UCG technology has been known for some time and considered a promising method for unconventional fossil fuel resources exploitation, there are limited modelling studies which achieve the necessary accuracy and realistic simulation of the processes involved. This paper uses the existing knowledge for surface gasifiers and investigates process designs which could be adapted to model UCG. Steady state simulations of syngas production were developed using the Advanced System for Process ENgineering (Aspen) Plus software. The Gibbs free energy minimisation method was used to simulate the different chemical reactor blocks which were combined using a FORTRAN code written. This approach facilitated the realistic simulation of the gasification process. A number of model configurations were developed to simulate different subsurface gasifier layouts considered for the exploitation of underground coal seams. The two gasifier layouts considered here are the linked vertical boreholes and the controlled retractable injection point (CRIP) methods. Different stages of the UCG process (i.e. initialisation, intermediate, end-phase) as well as the temperature level of the syngas collection point in each layout were found to be the two most decisive and distinctive parameters during the design of the optimal model configuration for each layout. Sensitivity analyses were conducted to investigate the significance of the operational parameters and the performance indicators used to evaluate the results. The operational parameters considered were the type of reagents injected (i.e. O2, N2, CO2, H2O), the ratio between the injected reagents and the feedstock quantity (i.e. coal), the pressure, the gasification and the combustion temperatures. The performance indicators included the composition and the energy content of the product gas as well as the carbon and energy efficiency achieved under each operational scenario. Different operational scenarios for every model configuration facilitated the cross-comparison among different configurations. The proximate and ultimate analysis data for the coal seams modelled were taken from a number of candidate UCG sites (Durucan et al., 2014) .The model findings were validated using the results of field trials reported in the literature. It was found that, increased gasification temperature leads to higher H2 and CO quantities in the product gas. Moreover, CH4 and CO2 concentrations increased as reaction pressure increased, while the CH4 quantity reached its highest value at the highest operational pressure, when combined with the lowest gasification temperature. The simulation models developed can be used to design and validate experimental UCG studies and offer significant advantages in terms of time and resource savings. As the UCG process consists of interrelated stages and a number of diverse phenomena, therefore, the gasification designs developed could act as the basis for an integrated UCG model tailored to the needs of a UCG pilot plant.
Code of Federal Regulations, 2010 CFR
2010-07-01
... RECLAMATION OPERATIONS PERMITS AND COAL EXPLORATION SYSTEMS UNDER REGULATORY PROGRAMS UNDERGROUND MINING PERMIT APPLICATIONS-MINIMUM REQUIREMENTS FOR RECLAMATION AND OPERATION PLAN § 784.1 Scope. This part... mining operations and reclamation plans portions of applications for permits for underground mining...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Riggs, J.B.
An experimental test model, which is dynamically similar to an actual UCC (Underground Coal Conversion) system, was used to determine fluid-flow patterns and local heat transfer that occur in the UCC burn cavity. This study was designed to provide insight into the little understood mechanisms (i.e., heat transfer and oxygen transport to the cavity walls) that control maximum cavity width, and therefore resource recovery during UCC. The experimental studies will be designed to study the effects of a growing cavity upon the transport to the side walls of a UCG cavity. The flow model will be used to study themore » effects of rubble pile shape changes upon the transport to the side walls.« less
30 CFR 75.1106 - Welding, cutting, or soldering with arc or flame underground.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Welding, cutting, or soldering with arc or... Protection § 75.1106 Welding, cutting, or soldering with arc or flame underground. [Statutory Provisions] All welding, cutting, or soldering with arc or flame in all underground areas of a coal mine shall, whenever...
30 CFR 75.1106 - Welding, cutting, or soldering with arc or flame underground.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Welding, cutting, or soldering with arc or... Protection § 75.1106 Welding, cutting, or soldering with arc or flame underground. [Statutory Provisions] All welding, cutting, or soldering with arc or flame in all underground areas of a coal mine shall, whenever...
30 CFR 75.1106 - Welding, cutting, or soldering with arc or flame underground.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Welding, cutting, or soldering with arc or... Protection § 75.1106 Welding, cutting, or soldering with arc or flame underground. [Statutory Provisions] All welding, cutting, or soldering with arc or flame in all underground areas of a coal mine shall, whenever...
30 CFR 75.1106 - Welding, cutting, or soldering with arc or flame underground.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Welding, cutting, or soldering with arc or... Protection § 75.1106 Welding, cutting, or soldering with arc or flame underground. [Statutory Provisions] All welding, cutting, or soldering with arc or flame in all underground areas of a coal mine shall, whenever...
30 CFR 75.1106 - Welding, cutting, or soldering with arc or flame underground.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Welding, cutting, or soldering with arc or... Protection § 75.1106 Welding, cutting, or soldering with arc or flame underground. [Statutory Provisions] All welding, cutting, or soldering with arc or flame in all underground areas of a coal mine shall, whenever...
A survey of atmospheric monitoring systems in U.S. underground coal mines
Rowland, J.H.; Harteis, S.P.; Yuan, L.
2018-01-01
In 1995 and 2003, the U.S. Mine Safety and Health Administration (MSHA) conducted surveys to determine the number of atmospheric monitoring systems (AMS) that were being used in underground coal mines in the United States. The survey reports gave data for the different AMS manufacturers, the different types of equipment monitored, and the different types of gas sensors and their locations. Since the last survey in 2003, MSHA has changed the regulation requirements for early fire detection along belt haulage entries. As of Dec. 31, 2009, point-type heat sensors are prohibited for use for an early fire detection system. Instead, carbon monoxide (CO) sensors are now required. This report presents results from a new survey and examines how the regulation changes have had an impact on the use of CO sensors in underground coal mines in the United States. The locations and parameters monitored by AMS and CO systems are also discussed. PMID:29674789
NASA Astrophysics Data System (ADS)
Szlązak, Nikodem; Korzec, Marek
2016-06-01
Methane has a bad influence on safety in underground mines as it is emitted to the air during mining works. Appropriate identification of methane hazard is essential to determining methane hazard prevention methods, ventilation systems and methane drainage systems. Methane hazard is identified while roadways are driven and boreholes are drilled. Coalbed methane content is one of the parameters which is used to assess this threat. This is a requirement according to the Decree of the Minister of Economy dated 28 June 2002 on work safety and hygiene, operation and special firefighting protection in underground mines. For this purpose a new method for determining coalbed methane content in underground coal mines has been developed. This method consists of two stages - collecting samples in a mine and testing the sample in the laboratory. The stage of determining methane content in a coal sample in a laboratory is essential. This article presents the estimation of measurement uncertainty of determining methane content in a coal sample according to this methodology.
Slaker, Brent A.; Mohamed, Khaled M.
2017-01-01
Understanding coal mine rib behavior is important for inferring pillar loading conditions as well as ensuring the safety of miners who are regularly exposed to ribs. Due to the variability in the geometry of underground openings and ground behavior, point measurements often fail to capture the true movement of mine workings. Photogrammetry is a potentially fast, cheap, and precise supplemental measurement tool in comparison to extensometers, tape measures, or laser range meters, but its application in underground coal has been limited. The practical use of photogrammetry was tested at the Safety Research Coal Mine, National Institute for Occupational Safety and Health (NIOSH). A commercially available, digital single-lens reflex (DSLR) camera was used to perform the photogrammetric surveys for the experiment. Several experiments were performed using different lighting conditions, distances to subject, camera settings, and photograph overlaps, with results summarized as follows: the lighting method was found to be insignificant if the scene was appropriately illuminated. It was found that the distance to the subject has a minimal impact on result accuracy, and that camera settings have a significant impact on the photogrammetric quality of images. An increasing photograph resolution was preferable when measuring plane orientations; otherwise a high point cloud density would likely be excessive. Focal ratio (F-stop) changes affect the depth of field and image quality in situations where multiple angles are necessary to survey cleat orientations. Photograph overlap is very important to proper three-dimensional reconstruction, and at least 60% overlap between photograph pairs is ideal to avoid unnecessary post-processing. The suggestions and guidelines proposed are designed to increase the quality of photogrammetry inputs and outputs as well as minimize processing time, and serve as a starting point for an underground coal photogrammetry study. PMID:28663826
Slaker, Brent A; Mohamed, Khaled M
2017-01-01
Understanding coal mine rib behavior is important for inferring pillar loading conditions as well as ensuring the safety of miners who are regularly exposed to ribs. Due to the variability in the geometry of underground openings and ground behavior, point measurements often fail to capture the true movement of mine workings. Photogrammetry is a potentially fast, cheap, and precise supplemental measurement tool in comparison to extensometers, tape measures, or laser range meters, but its application in underground coal has been limited. The practical use of photogrammetry was tested at the Safety Research Coal Mine, National Institute for Occupational Safety and Health (NIOSH). A commercially available, digital single-lens reflex (DSLR) camera was used to perform the photogrammetric surveys for the experiment. Several experiments were performed using different lighting conditions, distances to subject, camera settings, and photograph overlaps, with results summarized as follows: the lighting method was found to be insignificant if the scene was appropriately illuminated. It was found that the distance to the subject has a minimal impact on result accuracy, and that camera settings have a significant impact on the photogrammetric quality of images. An increasing photograph resolution was preferable when measuring plane orientations; otherwise a high point cloud density would likely be excessive. Focal ratio (F-stop) changes affect the depth of field and image quality in situations where multiple angles are necessary to survey cleat orientations. Photograph overlap is very important to proper three-dimensional reconstruction, and at least 60% overlap between photograph pairs is ideal to avoid unnecessary post-processing. The suggestions and guidelines proposed are designed to increase the quality of photogrammetry inputs and outputs as well as minimize processing time, and serve as a starting point for an underground coal photogrammetry study.
NASA Astrophysics Data System (ADS)
Kataka, M. O.; Matiane, A. R.; Odhiambo, B. D. O.
2018-01-01
Spontaneous combustion of coal is a major hazard associated with the coal mining industry over centuries. It also a major cause of underground fires in South African collieries and in opencast operations, spoil heaps and stockpiles. Spontaneous combustion incidents are manifested in all major aspects of coal mining namely, underground mining, surface mining, including during sea-borne transportation, storage and waste disposal. Previous studies indicate that there are various factors (both intrinsic and extrinsic) that influence the spontaneous combustion of coals. This paper characterizes highly reactive coal from the Vryheid coalfields and less reactive coal from at Venda-Pafuri coalfield, to identify and delineate some intrinsic coal parameters that are considered to be most critical in terms of heat 'generation' and relationships between the two coals types by tracing their similarities and differences in their spontaneous combustion parameters. Various tests were carried out to characterize these coals in terms of their intrinsic properties, namely: ultimate, proximate, petrographic analysis and Glasser spontaneous tests. The ultimate and proximate analysis showed that spontaneous coal has high contents of carbon, oxygen, and volatile matter as compared to non-spontaneous coal, making it more susceptible to spontaneous combustion. Non-spontaneous coal has higher ash content than the spontaneous coal. Furthermore, the petrographic analysis showed that spontaneous coal has high total reactivity compared to the non-spontaneous coal. Results from Glasser spontaneous test indicate that spontaneous coal absorbs more oxygen than non-spontaneous coal, which explains why spontaneous coal is more susceptible to spontaneous combustion. High reactive coal has low values of critical self-heating temperature (CSHT), indicating that this coal has potential of spontaneous ignition.
Coal deposits of the United States
John, Nelson W.
1987-01-01
The coal fields of the Unites States can be divided into six major provinces. The Appalachian and Interior Provinces contain dominantly bituminous coal in strata of Pennsylvanian age. The coal seams are relatively thin and are mined both by surface and underground methods. Sulfyur content is low to moderate in the Appalachian Province, generally high in the Interior province. The Gulf Coastal Plain Province, in Texas and neighboring states, contains lignite of Eocene age. The seams are 3-25 ft (0.9-7.5 m) thick and are minded in large open pits. The Northern Great Plains Province has lignite and subbituminous coal of Cretaceous, Paleocene and Eocene age. The coal, largely very low in sulfur, occurs in beds up to 100 ft (30 m) thick and is strip-mined. The Rocky Mountain Province contains a great variety of coal deposits in numerous separate intermontane basins. Most of it is low-sulfur subbituminous to bituminous coal iof Creatceous and early Tertiary age. The seams range from a few feet to over 100 ft (30 m) thick. Strip-mining dominates but underground mines are important in Utah and Colorado. The Pacific Coast Province, which includes Alaska, contains enormous cola resources but has seen little mining. The coal is highly diverse in physical character and geologic setting. ?? 1987.
Occupational safety and health implications of increased coal utilization.
Bridbord, K; Costello, J; Gamble, J; Groce, D; Hutchison, M; Jones, W; Merchant, J; Ortmeyer, C; Reger, R; Wagner, W L
1979-01-01
An area of major concern in considering increased coal production and utilization is the health and safety of increased numbers of workers who mine, process, or utilize coal. Hazards related to mining activities in the past have been especially serious, resulting in many mine related accidental deaths, disabling injuries, and disability and death from chronic lung disease. Underground coal mines are clearly less safe than surface mines. Over one-third of currently employed underground miners experience chronic lung disease. Other stresses include noise and extremes of heat and cold. Newly emphasized technologies of the use of diesel powered mining equipment and the use of longwall mining techniques may be associated with serious health effects. Workers at coal-fired power plants are also potentially at risk of occupational diseases. Occupational safety and health aspects of coal mining are understood well enough today to justify implementing necessary and technically feasible and available control measures to minimize potential problems associated with increased coal production and use in the future. Increased emphasis on safety and health training for inexperienced coal miners expected to enter the work force is clearly needed. The recently enacted Federal Mine Safety and Health Act of 1977 will provide impetus for increased control over hazards in coal mining. PMID:540621
A Closed Network Queue Model of Underground Coal Mining Production, Failure, and Repair
NASA Technical Reports Server (NTRS)
Lohman, G. M.
1978-01-01
Underground coal mining system production, failures, and repair cycles were mathematically modeled as a closed network of two queues in series. The model was designed to better understand the technological constraints on availability of current underground mining systems, and to develop guidelines for estimating the availability of advanced mining systems and their associated needs for spares as well as production and maintenance personnel. It was found that: mine performance is theoretically limited by the maintainability ratio, significant gains in availability appear possible by means of small improvements in the time between failures the number of crews and sections should be properly balanced for any given maintainability ratio, and main haulage systems closest to the mine mouth require the most attention to reliability.
30 CFR 817.180 - Utility installations.
Code of Federal Regulations, 2010 CFR
2010-07-01
... PERMANENT PROGRAM PERFORMANCE STANDARDS PERMANENT PROGRAM PERFORMANCE STANDARDS-UNDERGROUND MINING ACTIVITIES § 817.180 Utility installations. All underground mining activities shall be conducted in a manner...; oil, gas, and coal-slurry pipelines, railroads; electric and telephone lines; and water and sewage...
30 CFR 77.100 - Certified person.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Certified person. 77.100 Section 77.100 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES Qualified and Certified Persons § 77.100 Certified...
30 CFR 77.411 - Compressed air and boilers; general.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Compressed air and boilers; general. 77.411 Section 77.411 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES Safeguards for Mechanical Equipment ...
30 CFR 77.411 - Compressed air and boilers; general.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Compressed air and boilers; general. 77.411 Section 77.411 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES Safeguards for Mechanical Equipment ...
30 CFR 77.411 - Compressed air and boilers; general.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Compressed air and boilers; general. 77.411 Section 77.411 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES Safeguards for Mechanical Equipment ...
30 CFR 77.411 - Compressed air and boilers; general.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Compressed air and boilers; general. 77.411 Section 77.411 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES Safeguards for Mechanical Equipment ...
30 CFR 77.411 - Compressed air and boilers; general.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Compressed air and boilers; general. 77.411 Section 77.411 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES Safeguards for Mechanical Equipment ...
Forecast of long term coal supply and mining conditions: Model documentation and results
NASA Technical Reports Server (NTRS)
1980-01-01
A coal industry model was developed to support the Jet Propulsion Laboratory in its investigation of advanced underground coal extraction systems. The model documentation includes the programming for the coal mining cost models and an accompanying users' manual, and a guide to reading model output. The methodology used in assembling the transportation, demand, and coal reserve components of the model are also described. Results presented for 1986 and 2000, include projections of coal production patterns and marginal prices, differentiated by coal sulfur content.
You, Kaiming; Yang, Wei; Han, Ruisong
2015-09-29
Based on wireless multimedia sensor networks (WMSNs) deployed in an underground coal mine, a miner's lamp video collaborative localization algorithm was proposed to locate miners in the scene of insufficient illumination and bifurcated structures of underground tunnels. In bifurcation area, several camera nodes are deployed along the longitudinal direction of tunnels, forming a collaborative cluster in wireless way to monitor and locate miners in underground tunnels. Cap-lamps are regarded as the feature of miners in the scene of insufficient illumination of underground tunnels, which means that miners can be identified by detecting their cap-lamps. A miner's lamp will project mapping points on the imaging plane of collaborative cameras and the coordinates of mapping points are calculated by collaborative cameras. Then, multiple straight lines between the positions of collaborative cameras and their corresponding mapping points are established. To find the three-dimension (3D) coordinate location of the miner's lamp a least square method is proposed to get the optimal intersection of the multiple straight lines. Tests were carried out both in a corridor and a realistic scenario of underground tunnel, which show that the proposed miner's lamp video collaborative localization algorithm has good effectiveness, robustness and localization accuracy in real world conditions of underground tunnels.
NASA Astrophysics Data System (ADS)
Wang, Hongwei; Xue, Sheng; Jiang, Yaodong; Deng, Daixin; Shi, Suzhen; Zhang, Dengqiang
2018-06-01
An investigation was undertaken to study the characteristics of large roadway deformation and driving force of roof fall in a geologically complex zone at Huangyanhui underground coal mine, Shanxi Province, China, and to determine the main factors contributing to a roof fall accident that occurred in this mine. A series of field tests were conducted in the mine to study the geological structures, in situ stress, excavation-damaged zones of the roadway, roof-to-floor and sidewall convergences, roof separation, bolts loading and island coal pillar stress. The results of these tests have revealed that the driving force of the large roadway deformation and roof fall was not the activation of the karst collapsed pillars or concentration stress in island coal pillar, but high levels of horizontal tectonic stress and fault slip were induced by mining activities.
Technogenic effect of liquidation of coal mines on earth’s entrails: hydrogeochemical aspect
NASA Astrophysics Data System (ADS)
Tarasenko, I. A.; Zinkov, A. V.; Chudaev, O. V.; Vetoshkina, A. V.; Holodilov, I. I.
2017-10-01
The authors of the paper have established the geochemical features of the composition of underground waters and regularities of their formation in the areas of the liquidated coal mines of Russia and Ukraine. It is shown that the mine flood resulted in the formation of technogenic waters which geochemical specificity originates in the feeding field and is transformed in the direction of the filtration flow. It depends on the geological structure of sedimentary basins and the presence in the coal and supra-coal beds of the marine, salt-bearing and freshwater groups of geological formations. The water types are distinguished characterizing the conditions and processes of their formation that may be the regional markers in the hydrochemical and geological constructions. The technogenic waters influenced the safety of the underground waters, sources of water supply of the regions, and surface water channels. The pollutions are of local character in space.
Respiratory predictors of disability days: a five year prospective study of U. S. coal miners
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ames, R.G.; Trent, R.B.
1985-01-01
A 5-year prospective analysis tests the hypothesis that coal miners who have impaired respiratory health also experience greater numbers of disability days due to occupational injury. Occupational and respiratory health information collected for the period 1977 through 1981 by the National Institute for Occupational Safety and Health (NIOSH) on 1,118 U.S. underground coal miners was linked to coal miner injury records collected under a mandatory reporting system by the Mine Safety and Health Administration (MSHA). Respiratory impairment, based on spirometric measures, and a questionnaire measure of chronic bronchitis symptoms, after adjustment for cigarette smoking and total years of underground mining,more » did not provide statistically significant prediction of average disability days. In addition, respiratory impairment did not predict the number of episodes of occupational injuries resulting in days lost from work.« less
Mining injuries in Serbian underground coal mines -- a 10-year study.
Stojadinović, Saša; Svrkota, Igor; Petrović, Dejan; Denić, Miodrag; Pantović, Radoje; Milić, Vitomir
2012-12-01
Mining, especially underground coal mining, has always been a dangerous occupation. Injuries, unfortunately, even those resulting in death, are one of the major occupational risks that all miners live with. Despite the fact that all workers are aware of the risk, efforts must be and are being made to increase the safety of mines. Injury monitoring and data analysis can provide us with valuable data on the causes of accidents and enable us to establish a correlation between the conditions in the work environment and the number of injuries, which can further lead to proper preventive measures. This article presents the data on the injuries in Serbian coal mines during a 10-year period (2000-2009). The presented results are only part of an ongoing study whose aim is to assess the safety conditions in Serbian coal mines and classify them according to that assessment. Copyright © 2011 Elsevier Ltd. All rights reserved.
Emissions from Coal Fires and Their Impact on the Environment
Kolker, Allan; Engle, Mark; Stracher, Glenn; Hower, James; Prakash, Anupma; Radke, Lawrence; ter Schure, Arnout; Heffern, Ed
2009-01-01
Self-ignited, naturally occurring coal fires and fires resulting from human activities persist for decades in underground coal mines, coal waste piles, and unmined coal beds. These uncontrolled coal fires occur in all coal-bearing parts of the world (Stracher, 2007) and pose multiple threats to the global environment because they emit greenhouse gases - carbon dioxide (CO2), and methane (CH4) - as well as mercury (Hg), carbon monoxide (CO), and other toxic substances (fig. 1). The contribution of coal fires to the global pool of atmospheric CO2 is little known but potentially significant. For China, the world's largest coal producer, it is estimated that anywhere between 10 million and 200 million metric tons (Mt) of coal reserves (about 0.5 to 10 percent of production) is consumed annually by coal fires or made inaccessible owing to fires that hinder mining operations (Rosema and others, 1999; Voigt and others, 2004). At this proportion of production, coal amounts lost to coal fires worldwide would be two to three times that for China. Assuming this coal has mercury concentrations similar to those in U.S. coals, a preliminary estimate of annual Hg emissions from coal fires worldwide is comparable in magnitude to the 48 tons of annual Hg emissions from all U.S. coal-fired power-generating stations combined (U.S. Environmental Protection Agency, 2002). In the United States, the combined cost of coal-fire remediation projects, completed, budgeted, or projected by the U.S. Department of the Interior's Office of Surface Mining Reclamation and Enforcement (OSM), exceeds $1 billion, with about 90% of that in two States - Pennsylvania and West Virginia (Office of Surface Mining Enforcement and Reclamation, 2008; fig. 2). Altogether, 15 States have combined cumulative OSM coal-fire project costs exceeding $1 million, with the greatest overall expense occurring in States where underground coal fires are predominant over surface fires, reflecting the greater cost of extinguishing underground fires (fig. 2) (see 'Controlling Coal Fires'). In this fact sheet we review how coal fires occur, how they can be detected by airborne and remote surveys, and, most importantly, the impact coal-fire emissions may have on the environment and human health. In addition, we describe recent efforts by the U.S. Geological Survey (USGS) and collaborators to measure fluxes of CO2, CO, CH4, and Hg, using groundbased portable detectors, and combining these approaches with airborne thermal imaging and CO2 measurements. The goal of this research is to develop approaches that can be extrapolated to large fires and to extrapolate results for individual fires in order to estimate the contribution of coal fires as a category of global emissions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hudgel, D.W.; Roe, R.
Because nonsmoking underground bituminous coal miners often have symptoms of chronic bronchitis and because a high proportion of patients with chronic bronchitis have nonspecific airway hyperreactivity, we hypothesized that coal miners would have a higher prevalence of nonspecific airway hyperreactivity than nonminer nonsmoking control subjects. By use of a quantitative methacholine provocative inhalation challenge test, we evaluated 22 underground bituminous coal miners and 41 nonminer age- and sex-matched control subjects from the same community. We found that a significantly higher proportion of miners had reactivity to inhalation of 100 mg/ml or less of methacholine, X2 = 6.19, p less thanmore » 0.02. The slope of phase III of the single-breath nitrogen washout test was higher in the reactive miners than in the nonreactive miners and reactive control subjects, even though the reactive miners had only been working underground 8 +/- 3 (SEM) years. Within the reactive miner subgroup, the higher the reactivity to methacholine, the more abnormal the slope of phase III of the single-breath nitrogen test, r = 0.79. Miners had more symptoms than controls; the presence of methacholine reactivity was not associated with increased symptoms. We conclude that the bituminous coal miners in our study had an increased prevalence of nonspecific airway hyperreactivity and that within the reactive miner subgroup there was evidence of early airways disease. We speculate that the nonspecific airway hyperreactivity may be related to, and also be an indicator of, lung injury in coal miners.« less
30 CFR 77.506 - Electric equipment and circuits; overload and short-circuit protection.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Electric equipment and circuits; overload and short-circuit protection. 77.506 Section 77.506 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES...
30 CFR 77.506 - Electric equipment and circuits; overload and short-circuit protection.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Electric equipment and circuits; overload and short-circuit protection. 77.506 Section 77.506 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES...
30 CFR 77.506 - Electric equipment and circuits; overload and short-circuit protection.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Electric equipment and circuits; overload and short-circuit protection. 77.506 Section 77.506 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES...
30 CFR 77.506 - Electric equipment and circuits; overload and short-circuit protection.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Electric equipment and circuits; overload and short-circuit protection. 77.506 Section 77.506 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES...
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false First aid training program; retraining of..., SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES Miscellaneous § 77.1705 First aid..., 1972, each operator of a surface coal mine shall conduct refresher first aid training programs each...
ERIC Educational Resources Information Center
Marovelli, Robert L.; Karhnak, John M.
1982-01-01
Mechanization of mining is explained in terms of its effect on the mining of coal, focusing on, among others, types of mining, productivity, machinery, benefits to retired miners, fatality rate in underground coal mines, and output of U.S. mining industry. (Author/JN)
Feng, Xiaowei; Zhang, Nong; Zheng, Xigui; Pan, Dongjiang
2015-01-01
Underground rock masses have shown a general trend of natural balance over billions of years of ground movement. Nonetheless, man-made underground constructions disturb this balance and cause rock stability failure. Fractured rock masses are frequently encountered in underground constructions, and this study aims to restore the strength of rock masses that have experienced considerable fracturing under uniaxial compression. Coal and sandstone from a deep-buried coal mine were chosen as experimental subjects; they were crushed by uniaxial compression and then carefully restored by a chemical adhesive called MEYCO 364 with an innovative self-made device. Finally, the restored specimens were crushed once again by uniaxial compression. Axial stress, axial strain, circumferential strain, and volumetric strain data for the entire process were fully captured and are discussed here. An acoustic emission (AE) testing system was adopted to cooperate with the uniaxial compression system to provide better definitions for crack closure thresholds, crack initiation thresholds, crack damage thresholds, and three-dimensional damage source locations in intact and restored specimens. Several remarkable findings were obtained. The restoration effects of coal are considerably better than those of sandstone because the strength recovery coefficient of the former is 1.20, whereas that of the latter is 0.33, which indicates that MEYCO 364 is particularly valid for fractured rocks whose initial intact peak stress is less than that of MEYCO 364. Secondary cracked traces of restored sandstone almost follow the cracked traces of the initial intact sandstone, and the final failure is mainly caused by decoupling between the adhesive and the rock mass. However, cracked traces of restored coal only partially follow the traces of intact coal, with the final failure of the restored coal being caused by both bonding interface decoupling and self-breakage in coal. Three-dimensional damage source locations manifest such that AE events are highly correlated with a strength recovery coefficient; the AE events show a decreasing tendency when the coefficient is larger than 1, and vice versa. This study provides a feasible scheme for the reinforcement of fractured rock masses in underground constructions and reveals an internal mechanism of the crushing process for restored rock masses, which has certain instructive significance.
Feng, Xiaowei; Zhang, Nong; Zheng, Xigui; Pan, Dongjiang
2015-01-01
Underground rock masses have shown a general trend of natural balance over billions of years of ground movement. Nonetheless, man-made underground constructions disturb this balance and cause rock stability failure. Fractured rock masses are frequently encountered in underground constructions, and this study aims to restore the strength of rock masses that have experienced considerable fracturing under uniaxial compression. Coal and sandstone from a deep-buried coal mine were chosen as experimental subjects; they were crushed by uniaxial compression and then carefully restored by a chemical adhesive called MEYCO 364 with an innovative self-made device. Finally, the restored specimens were crushed once again by uniaxial compression. Axial stress, axial strain, circumferential strain, and volumetric strain data for the entire process were fully captured and are discussed here. An acoustic emission (AE) testing system was adopted to cooperate with the uniaxial compression system to provide better definitions for crack closure thresholds, crack initiation thresholds, crack damage thresholds, and three-dimensional damage source locations in intact and restored specimens. Several remarkable findings were obtained. The restoration effects of coal are considerably better than those of sandstone because the strength recovery coefficient of the former is 1.20, whereas that of the latter is 0.33, which indicates that MEYCO 364 is particularly valid for fractured rocks whose initial intact peak stress is less than that of MEYCO 364. Secondary cracked traces of restored sandstone almost follow the cracked traces of the initial intact sandstone, and the final failure is mainly caused by decoupling between the adhesive and the rock mass. However, cracked traces of restored coal only partially follow the traces of intact coal, with the final failure of the restored coal being caused by both bonding interface decoupling and self-breakage in coal. Three-dimensional damage source locations manifest such that AE events are highly correlated with a strength recovery coefficient; the AE events show a decreasing tendency when the coefficient is larger than 1, and vice versa. This study provides a feasible scheme for the reinforcement of fractured rock masses in underground constructions and reveals an internal mechanism of the crushing process for restored rock masses, which has certain instructive significance. PMID:26714324
Development of minimum standards for hardwoods used in producing underground coal mine timbers
Floyd G. Timson
1978-01-01
This note presents minimum standards for raw material used in the production of sawn, split, and round timbers for the underground mining industry. The standards are based on a summary of information gathered from many mine-timber producers.
76 FR 73885 - Mandatory Reporting of Greenhouse Gases
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-29
.... 211112 Natural gas liquid extraction facilities. Underground Coal Mines........ 212113 Underground... natural gas liquids in addition to suppliers of petroleum products. 2. Summary of Comments and Responses... Mandatory Reporting of Greenhouse Gases; Final Rule #0;#0;Federal Register / Vol. 76, No. 229 / Tuesday...
NASA Technical Reports Server (NTRS)
Boothe, W. A.; Corman, J. C.; Johnson, G. G.; Cassel, T. A. V.
1976-01-01
Results are presented of an investigation of gasification and clean fuels from coal. Factors discussed include: coal and coal transportation costs; clean liquid and gas fuel process efficiencies and costs; and cost, performance, and environmental intrusion elements of the integrated low-Btu coal gasification system. Cost estimates for the balance-of-plant requirements associated with advanced energy conversion systems utilizing coal or coal-derived fuels are included.
Manual of good practices for sanitation in coal mining operations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
The purpose of the manual was to act as a guideline, setting reasonable recommendations relative to mine sanitation which will enable mines to install adequate facilities and make appropriate alterations conserving and improving the health and welfare of the mine worker. A systematic evaluation was undertaken of the sanitation facilities and maintenance at coal mines. Consideration was given to central facilities including building, floors, walls, partitions, ceilings, lockers, baskets and benches, showers, toilets, lavatories, lighting, ventilation and temperature control, and maintenance. Also discussed were food vending machines, water source, water quality, water treatment, water delivery systems for underground and surfacemore » mines, sanitary waste disposal, workplace toilets in underground and surface mines, refuse control and handling for underground and surface mines, and pest control.« less
Coal face measurement system for underground use
NASA Technical Reports Server (NTRS)
1981-01-01
A measurement system was developed for the Eickhoff longwall shearer to determine the contour of the coal face as it mines coal. Contour data are obtained by an indirect measurement technique based on evaluating the motion of the shearer during mining. Starting from a known location, points along the coal face are established through a knowledge of the machines' positions and yaw movements as it moves past the coal face. The hardware and system operation procedures are described. The tests of system performance and their results are reported.
Greening coal: breakthroughs and challenges in carbon capture and storage.
Stauffer, Philip H; Keating, Gordon N; Middleton, Richard S; Viswanathan, Hari S; Berchtold, Kathryn A; Singh, Rajinder P; Pawar, Rajesh J; Mancino, Anthony
2011-10-15
Like it or not, coal is here to stay, for the next few decades at least. Continued use of coal in this age of growing greenhouse gas controls will require removing carbon dioxide from the coal waste stream. We already remove toxicants such as sulfur dioxide and mercury, and the removal of CO₂ is the next step in reducing the environmental impacts of using coal as an energy source (i.e., greening coal). This paper outlines some of the complexities encountered in capturing CO₂ from coal, transporting it large distances through pipelines, and storing it safely underground.
30 CFR 784.30 - Support facilities.
Code of Federal Regulations, 2010 CFR
2010-07-01
... COAL MINING AND RECLAMATION OPERATIONS PERMITS AND COAL EXPLORATION SYSTEMS UNDER REGULATORY PROGRAMS UNDERGROUND MINING PERMIT APPLICATIONS-MINIMUM REQUIREMENTS FOR RECLAMATION AND OPERATION PLAN § 784.30... description, plans, and drawings for each support facility to be constructed, used, or maintained within the...
30 CFR 77.1008 - Relocation of drills; safeguards.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Section 77.1008 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND... operator at all times when the drill is being moved. ...
Industrial Internet of Things: (IIoT) applications in underground coal mines.
Zhou, C; Damiano, N; Whisner, B; Reyes, M
2017-12-01
The Industrial Internet of Things (IIoT), a concept that combines sensor networks and control systems, has been employed in several industries to improve productivity and safety. U.S. National Institute for Occupational Safety and Health (NIOSH) researchers are investigating IIoT applications to identify the challenges of and potential solutions for transferring IIoT from other industries to the mining industry. Specifically, NIOSH has reviewed existing sensors and communications network systems used in U.S. underground coal mines to determine whether they are capable of supporting IIoT systems. The results show that about 40 percent of the installed post-accident communication systems as of 2014 require minimal or no modification to support IIoT applications. NIOSH researchers also developed an IIoT monitoring and control prototype system using low-cost microcontroller Wi-Fi boards to detect a door opening on a refuge alternative, activate fans located inside the Pittsburgh Experimental Mine and actuate an alarm beacon on the surface. The results of this feasibility study can be used to explore IIoT applications in underground coal mines based on existing communication and tracking infrastructure.
Samantra, Chitrasen; Datta, Saurav; Mahapatra, Siba Sankar
2017-09-01
This paper presents a unique hierarchical structure on various occupational health hazards including physical, chemical, biological, ergonomic and psychosocial hazards, and associated adverse consequences in relation to an underground coal mine. The study proposes a systematic health hazard risk assessment methodology for estimating extent of hazard risk using three important measuring parameters: consequence of exposure, period of exposure and probability of exposure. An improved decision making method using fuzzy set theory has been attempted herein for converting linguistic data into numeric risk ratings. The concept of 'centre of area' method for generalized triangular fuzzy numbers has been explored to quantify the 'degree of hazard risk' in terms of crisp ratings. Finally, a logical framework for categorizing health hazards into different risk levels has been constructed on the basis of distinguished ranges of evaluated risk ratings (crisp). Subsequently, an action requirement plan has been suggested, which could provide guideline to the managers for successfully managing health hazard risks in the context of underground coal mining exercise.
Insertion loss of noise barriers on an aboveground, full-scale model longwall coal mining shearer.
Sweeney, Daniel D; Slagley, Jeremy M; Smith, David A
2010-05-01
The U.S. mining industry struggles with hazardous noise and dust exposures in underground mining. Specifically, longwall coal mine shearer operators are routinely exposed to noise levels at 151% of the allowable daily dose, and approximately 20% exceed regulatory dust levels. In the current study, a partial barrier was mounted on the full-scale mock shearer at the National Institute for Occupational Safety and Health Pittsburgh Research Laboratory. A simulated, full-scale, coal mine longwall shearer operation was employed to test the feasibility of utilizing a barrier to separate the shearer operator from the direct path of the noise and dust source during mining operations. In this model, noise levels at the operators' positions were reduced by 2.6 to 8.2 A-weighted decibels (dBA) from the application of the test barriers. Estimated insertion loss underground was 1.7 to 7.3 dBA. The barrier should be tested in an underground mining operation to determine if it can reduce shearer operators' noise exposure to below regulatory limits.
Brooks, Tom
1986-01-01
The U.S. Bureau of Land Management may lease additional coal tracts in the Rapid Creek basin, Colorado. Springs in this basin are used as a water supply for the town of Palisade. The geohydrology of the basin is described and the potential hydrologic effects of underground coal mining in the basin summarized. Geologic formations in the basin consists of Cretaceous sandstone and shale, Tertiary sandstone, shale, and basalt, and unconsolidated deposits of Quaternary age. Some sandstone and coal beds are permeable, although bedrock in the basin typically is a confining bed. Unconsolidated deposits contain aquifers that are the source of spring discharge. Stream discharge was measured on Rapid and Cottonwood Creeks, and inventories were made of 7 reservoirs, 25 springs, and 12 wells. Specific conductance of streams ranged from 320 to 1,050 microsiemens/cm at 25C; pH ranged from 7.8 to 8.6. Specific conductance of springs ranged from 95 to 1,050 microsiemens/cm at 25C; pH ranged from 6.8 to 8.3. Discharge from the basin includes about 18,800 acre-ft/yr as evapotranspiration, 1,300 acre-ft/yr as springflow, 1,280 acre-ft/yr as streamflow, and negligible groundwater flow in bedrock. With appropriate mining methods, underground mining would not decrease flow in basin streams or from springs. The potential effects of mining-caused subsidence might include water-pipeline damage and temporary dewatering of bedrock adjacent to coal mining. (Author 's abstract)
Protective and control relays as coal-mine power-supply ACS subsystem
NASA Astrophysics Data System (ADS)
Kostin, V. N.; Minakova, T. E.
2017-10-01
The paper presents instantaneous selective short-circuit protection for the cabling of the underground part of a coal mine and central control algorithms as a Coal-Mine Power-Supply ACS Subsystem. In order to improve the reliability of electricity supply and reduce the mining equipment down-time, a dual channel relay protection and central control system is proposed as a subsystem of the coal-mine power-supply automated control system (PS ACS).
30 CFR 75.1703 - Portable electric lamps.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Portable electric lamps. 75.1703 Section 75... HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1703 Portable electric lamps. [Statutory Provisions] Persons underground shall use only permissible electric lamps approved by the...
30 CFR 75.1703 - Portable electric lamps.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Portable electric lamps. 75.1703 Section 75... HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1703 Portable electric lamps. [Statutory Provisions] Persons underground shall use only permissible electric lamps approved by the...
30 CFR 75.1703 - Portable electric lamps.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Portable electric lamps. 75.1703 Section 75... HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1703 Portable electric lamps. [Statutory Provisions] Persons underground shall use only permissible electric lamps approved by the...
30 CFR 75.1703 - Portable electric lamps.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Portable electric lamps. 75.1703 Section 75... HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1703 Portable electric lamps. [Statutory Provisions] Persons underground shall use only permissible electric lamps approved by the...
30 CFR 75.1703 - Portable electric lamps.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Portable electric lamps. 75.1703 Section 75... HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1703 Portable electric lamps. [Statutory Provisions] Persons underground shall use only permissible electric lamps approved by the...
30 CFR 75.1702 - Smoking; prohibition.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Smoking; prohibition. 75.1702 Section 75.1702... MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1702 Smoking; prohibition. [Statutory Provisions] No person shall smoke, carry smoking materials, matches, or lighters underground, or smoke in or...
30 CFR 75.1702 - Smoking; prohibition.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Smoking; prohibition. 75.1702 Section 75.1702... MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1702 Smoking; prohibition. [Statutory Provisions] No person shall smoke, carry smoking materials, matches, or lighters underground, or smoke in or...
30 CFR 75.1702 - Smoking; prohibition.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Smoking; prohibition. 75.1702 Section 75.1702... MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1702 Smoking; prohibition. [Statutory Provisions] No person shall smoke, carry smoking materials, matches, or lighters underground, or smoke in or...
30 CFR 75.1702 - Smoking; prohibition.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Smoking; prohibition. 75.1702 Section 75.1702... MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1702 Smoking; prohibition. [Statutory Provisions] No person shall smoke, carry smoking materials, matches, or lighters underground, or smoke in or...
30 CFR 75.1702 - Smoking; prohibition.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Smoking; prohibition. 75.1702 Section 75.1702... MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1702 Smoking; prohibition. [Statutory Provisions] No person shall smoke, carry smoking materials, matches, or lighters underground, or smoke in or...
Karra, Vijia K
2005-01-01
Mining injury surveillance data are used as the basis for assessing the severity of injuries among operator and contractor employees in the underground and surface mining of various minerals. Injury rates during 1983-2002 derived from Mine Safety and Health Administration (MSHA) database are analyzed using the negative binomial regression model. The logarithmic mean injury rate is expressed as a linear function of seven indicator variables representing Non-Coal Contractor, Metal Operator, Non Metal Operator, Stone Operator, Sand and Gravel Operator, Coal Contractor, and Work Location, and a continuous variable, RelYear, representing the relative year starting with 1983 as the base year. Based on the model, the mean injury rate declined at a 1.69% annual rate, and the mean injury rate for work on the surface is 52.53% lower compared to the rate for work in the underground. With reference to the Coal Operator mean injury rate: the Non-Coal Contractor rate is 30.34% lower, the Metal Operator rate is 27.18% lower, the Non-Metal Operator rate is 37.51% lower, the Stone Operator rate is 23.44% lower, the Sand and Gravel Operator rate is 16.45% lower, and the Coal Contractor rate is 1.41% lower. Fatality rates during the same 20 year period are analyzed similarly using Poisson regression model. Based on this model, the mean fatality rate declined at a 3.17% annual rate, and the rate for work on the surface is 64.3% lower compared to the rate for work in the underground. With reference to the Coal Operator mean fatality rate: the Non-Coal Contractor rate is 234.81% higher, the Metal Operator rate is 5.79% lower, the Non-Metal Operator rate is 47.36% lower, the Stone Operator rate is 8.29% higher, the Sand and Gravel Operator rate is 60.32% higher, and the Coal Contractor rate is 129.54% higher.
Hybrid Technology of Hard Coal Mining from Seams Located at Great Depths
NASA Astrophysics Data System (ADS)
Czaja, Piotr; Kamiński, Paweł; Klich, Jerzy; Tajduś, Antoni
2014-10-01
Learning to control fire changed the life of man considerably. Learning to convert the energy derived from combustion of coal or hydrocarbons into another type of energy, such as steam pressure or electricity, has put him on the path of scientific and technological revolution, stimulating dynamic development. Since the dawn of time, fossil fuels have been serving as the mankind's natural reservoir of energy in an increasingly great capacity. A completely incomprehensible refusal to use fossil fuels causes some local populations, who do not possess a comprehensive knowledge of the subject, to protest and even generate social conflicts as an expression of their dislike for the extraction of minerals. Our times are marked by the search for more efficient ways of utilizing fossil fuels by introducing non-conventional technologies of exploiting conventional energy sources. During apartheid, South Africa demonstrated that cheap coal can easily satisfy total demand for liquid and gaseous fuels. In consideration of current high prices of hydrocarbon media (oil and gas), gasification or liquefaction of coal seems to be the innovative technology convergent with contemporary expectations of both energy producers as well as environmentalists. Known mainly from literature reports, underground coal gasification technologies can be brought down to two basic methods: - shaftless method - drilling, in which the gasified seam is uncovered using boreholes drilled from the surface, - shaft method, in which the existing infrastructure of underground mines is used to uncover the seams. This paper presents a hybrid shaft-drilling approach to the acquisition of primary energy carriers (methane and syngas) from coal seams located at great depths. A major advantage of this method is the fact that the use of conventional coal mining technology requires the seams located at great depths to be placed on the off-balance sheet, while the hybrid method of underground gasification enables them to become a source of additional energy for the economy. It should be noted, however, that the shaft-drilling method cannot be considered as an alternative to conventional methods of coal extraction, but rather as a complementary and cheaper way of utilizing resources located almost beyond the technical capabilities of conventional extraction methods due to the associated natural hazards and high costs of combating them. This article presents a completely different approach to the issue of underground coal gasification. Repurposing of the already fully depreciated mining infrastructure for the gasification process may result in a large value added of synthesis gas production and very positive economic effect.
Coal rib response during bench mining: A case study
Sears, Morgan M.; Rusnak, John; Van Dyke, Mark; Rashed, Gamal; Mohamed, Khaled; Sloan, Michael
2018-01-01
In 2016, room-and-pillar mining provided nearly 40% of underground coal production in the United States. Over the past decade, rib falls have resulted in 12 fatalities, representing 28% of the ground fall fatalities in U.S. underground coal mines. Nine of these 12 fatalities (75%) have occurred in room-and-pillar mines. The objective of this research is to study the geomechanics of bench room-and-pillar mining and the associated response of high pillar ribs at overburden depths greater than 300 m. This paper provides a definition of the bench technique, the pillar response due to loading, observational data for a case history, a calibrated numerical model of the observed rib response, and application of this calibrated model to a second site. PMID:29862125
NASA Technical Reports Server (NTRS)
Wier, C. E.; Wobber, F. J. (Principal Investigator); Russell, O. R.; Amato, R. V.; Leshendok, T. V.
1974-01-01
The author has identified the following significant results. New fracture detail of Indiana has been observed and mapped from ERTS-1 imagery. Studies so far indicate a close relationship between the directions of fracture traces mapped from the imagery, fractures measured on bedrock outcrops, and fractures measured in the underground mines. First hand observations and discussions with underground mine operators indicate good correlation of mine hazard maps prepared from ERTS-1/aircraft imagery and actual roof falls. The inventory of refuse piles/slurry ponds of the coal field of Indiana has identified over 225 such sites from past mining operations. These data will serve the State Legislature in making tax decisions on coal mining which take on increased importance because of the energy crisis.
NASA Technical Reports Server (NTRS)
Kushida, R. O.; Sankur, V. D.; Gerbracht, F. G.; Mahajan, V.
1980-01-01
Techniques for achieving continuous coal sprays were studied. Coazial injection with gas and pressure atomization were studied. Coal particles, upon cooling, were found to be porous and fragile. Reactivity tests on the extruded coal showed overall conversion to gases and liquids unchanged from that of the raw coal. The potentials for applications of the coal pump to eight coal conversion processes were examined.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-13
..., the mining method or methods, and any comparable sales data on similar coal lands. The values given... resource to be offered is limited to coal recoverable by underground mining methods. The Federal coal is in.... Proprietary data marked as confidential may be submitted to the BLM in response to this solicitation of public...
You, Kaiming; Yang, Wei; Han, Ruisong
2015-01-01
Based on wireless multimedia sensor networks (WMSNs) deployed in an underground coal mine, a miner’s lamp video collaborative localization algorithm was proposed to locate miners in the scene of insufficient illumination and bifurcated structures of underground tunnels. In bifurcation area, several camera nodes are deployed along the longitudinal direction of tunnels, forming a collaborative cluster in wireless way to monitor and locate miners in underground tunnels. Cap-lamps are regarded as the feature of miners in the scene of insufficient illumination of underground tunnels, which means that miners can be identified by detecting their cap-lamps. A miner’s lamp will project mapping points on the imaging plane of collaborative cameras and the coordinates of mapping points are calculated by collaborative cameras. Then, multiple straight lines between the positions of collaborative cameras and their corresponding mapping points are established. To find the three-dimension (3D) coordinate location of the miner’s lamp a least square method is proposed to get the optimal intersection of the multiple straight lines. Tests were carried out both in a corridor and a realistic scenario of underground tunnel, which show that the proposed miner’s lamp video collaborative localization algorithm has good effectiveness, robustness and localization accuracy in real world conditions of underground tunnels. PMID:26426023
NASA Astrophysics Data System (ADS)
Tyulenev, Maxim; Lesin, Yury; Litvin, Oleg; Maliukhina, Elena; Abay, Asmelash
2017-11-01
Features of geological structure of the Kuznetsk coal basin stipulate the application of a low-cost open technique of coal mining, which is more advantageous both from the economic standpoint, and by safety criteria of mining. However, open mining affects significantly the water resources of region. Intensive pollution of reservoirs and water courses, exhaustion of the underground water-bearing layers, violation of a hydrographic network, etc. be-long to the main disadvantages of an open technique of coal mining. Besides, the volume of the water coming into the mining producers exceeds signi-ficantly the needed quantity. According to the data of annual reports of ecology and natural resources department, 348.277 million m3 of water were ta-ken away during production of soft coal, brown coal and lignum fossil from waters of Kemerovo region in 2013 (mostly from underground water objects (96,5%) when draining of mine openings). At the same time, only 87.018 million m3 of water (25%) has been used within a year.
Application of the Exergy UCG technology in international UCG projects
NASA Astrophysics Data System (ADS)
Blinderman, M. S.
2017-07-01
Underground Coal Gasification is a subject of continuing global interest in the energy sector. While the international scenario in UCG is promising, it is deeply desirable that advances in this area are seen in India as well. This is particularly so with the Paris Climate Agreement bringing in more stringent challenges for clean energy development. India has many potential coal basins which may be suitable for UCG deployment. India is in dire need of indigenous source of gaseous and liquid hydrocarbons that could compete with imported products. It is also the country with exceptionally large and diverse coal and lignite resources, large part of which could not be mined due to geological complexity and prohibitive cost. Thus, there is a rationale that the εUCG™ technology plays a decisive role in realizing the potential of Indian coal resources for the benefit of Indian industry and population. This article has been adapted by Dr. Ajay K. Singh from a lecture delivered at the “Workshop on Challenges and Opportunities of Underground Coal Gasification”, Vigyan Bhawan, New Delhi on 14 February 2017.
Occupational hazard evaluation model underground coal mine based on unascertained measurement theory
NASA Astrophysics Data System (ADS)
Deng, Quanlong; Jiang, Zhongan; Sun, Yaru; Peng, Ya
2017-05-01
In order to study how to comprehensively evaluate the influence of several occupational hazard on miners’ physical and mental health, based on unascertained measurement theory, occupational hazard evaluation indicator system was established to make quantitative and qualitative analysis. Determining every indicator weight by information entropy and estimating the occupational hazard level by credible degree recognition criteria, the evaluation model was programmed by Visual Basic, applying the evaluation model to occupational hazard comprehensive evaluation of six posts under a coal mine, and the occupational hazard degree was graded, the evaluation results are consistent with actual situation. The results show that dust and noise is most obvious among the coal mine occupational hazard factors. Excavation face support workers are most affected, secondly, heading machine drivers, coal cutter drivers, coalface move support workers, the occupational hazard degree of these four types workers is II mild level. The occupational hazard degree of ventilation workers and safety inspection workers is I level. The evaluation model could evaluate underground coal mine objectively and accurately, and can be employed to the actual engineering.
Monitoring and inversion on land subsidence over mining area with InSAR technique
Wang, Y.; Zhang, Q.; Zhao, C.; Lu, Z.; Ding, X.
2011-01-01
The Wulanmulun town, located in Inner Mongolia, is one of the main mining areas of Shendong Company such as Shangwan coal mine and Bulianta coal mine, which has been suffering serious mine collapse with the underground mine withdrawal. We use ALOS/PALSAR data to extract land deformation under these regions, in which Small Baseline Subsets (SBAS) method was applied. Then we compared InSAR results with the underground mining activities, and found high correlations between them. Lastly we applied Distributed Dislocation (Okada) model to invert the mine collapse mechanism. ?? 2011 Copyright Society of Photo-Optical Instrumentation Engineers (SPIE).
30 CFR 75.361 - Supplemental examination.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Ventilation § 75.361 Supplemental examination. (a) Except... examine the area for hazardous conditions, determine whether the air is traveling in its proper direction...
30 CFR 75.350 - Belt air course ventilation.
Code of Federal Regulations, 2010 CFR
2010-07-01
... HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Ventilation § 75.350 Belt air course ventilation... manager may approve lower velocities in the ventilation plan based on specific mine conditions. Air... or alarm signal. This training must be conducted prior to working underground in a mine that uses...
43 CFR 3461.1 - Underground mining exemption from criteria.
Code of Federal Regulations, 2014 CFR
2014-10-01
.... 3461.1 Section 3461.1 Public Lands: Interior Regulations Relating to Public Lands (Continued) BUREAU OF LAND MANAGEMENT, DEPARTMENT OF THE INTERIOR MINERALS MANAGEMENT (3000) ENVIRONMENT Federal Lands Review: Unsuitability for Mining § 3461.1 Underground mining exemption from criteria. (a) Federal lands with coal...
43 CFR 3461.1 - Underground mining exemption from criteria.
Code of Federal Regulations, 2013 CFR
2013-10-01
.... 3461.1 Section 3461.1 Public Lands: Interior Regulations Relating to Public Lands (Continued) BUREAU OF LAND MANAGEMENT, DEPARTMENT OF THE INTERIOR MINERALS MANAGEMENT (3000) ENVIRONMENT Federal Lands Review: Unsuitability for Mining § 3461.1 Underground mining exemption from criteria. (a) Federal lands with coal...
43 CFR 3461.1 - Underground mining exemption from criteria.
Code of Federal Regulations, 2012 CFR
2012-10-01
.... 3461.1 Section 3461.1 Public Lands: Interior Regulations Relating to Public Lands (Continued) BUREAU OF LAND MANAGEMENT, DEPARTMENT OF THE INTERIOR MINERALS MANAGEMENT (3000) ENVIRONMENT Federal Lands Review: Unsuitability for Mining § 3461.1 Underground mining exemption from criteria. (a) Federal lands with coal...
43 CFR 3461.1 - Underground mining exemption from criteria.
Code of Federal Regulations, 2011 CFR
2011-10-01
.... 3461.1 Section 3461.1 Public Lands: Interior Regulations Relating to Public Lands (Continued) BUREAU OF LAND MANAGEMENT, DEPARTMENT OF THE INTERIOR MINERALS MANAGEMENT (3000) ENVIRONMENT Federal Lands Review: Unsuitability for Mining § 3461.1 Underground mining exemption from criteria. (a) Federal lands with coal...
30 CFR 75.821 - Testing, examination and maintenance.
Code of Federal Regulations, 2010 CFR
2010-07-01
... SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Underground High-Voltage Distribution High-Voltage Longwalls § 75.821 Testing, examination and maintenance. (a) At least once every 7 days, a... must test and examine each unit of high-voltage longwall equipment and circuits to determine that...
30 CFR 75.817 - Cable handling and support systems.
Code of Federal Regulations, 2010 CFR
2010-07-01
... SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Underground High-Voltage Distribution High-Voltage Longwalls § 75.817 Cable handling and support systems. Longwall mining equipment must be... the possibility of miners contacting the cables and to protect the high-voltage cables from damage. ...
Krech, Sabina; Selinski, Silvia; Bürger, Hannah; Hengstler, Jan G; Jedrusik, Peter; Hodzic, Jasmin; Knopf, H-Jürgen; Golka, Klaus
2016-01-01
Currently, there is no established occupational risk factor for prostate cancer. However, in the 1980s, a hospital-based case-control study in the greater Dortmund area showed an elevated risk for hard coal miners and, based on few cases, for painters and varnishers. Therefore, approximately 10 yr later, a similar study regarding prostate cancer was performed in this area. In total, 292 patients with prostate cancer who underwent radical prostatectomy and 313 controls who underwent transurethral resection of a benign prostatic hyperplasia were investigated by questionnaire. All of them were operated on between 1995 and 1999. This study showed a decreased risk for prostate cancer in hard coal miners (odds ratio [OR] = 0.67, 95% confidence interval [CI] = 0.44-1.03). Occupational exposures related to an elevated risk for prostate cancer were exposures to combustion products (20% cases vs. 11% controls), colorants and dyes (19 vs. 13%), and cutting fluids (8 vs. 6%). The different prostate cancer risks for underground coal miners in two studies with a time interval of approximately 10 yr are striking. Factors to be discussed are the introduction of prostate-specific antigen (PSA) screening for prostate cancer and investigation of cases that underwent radical prostatectomy, where the disease in general is locally confined. Working conditions in the local underground coal mines improved over time but did not change markedly in the period of interest. In essence, the present study does not corroborate an elevated prostate cancer risk in former underground hard coal miners from the greater Dortmund area.
Barone, T L; Patts, J R; Janisko, S J; Colinet, J F; Patts, L D; Beck, T W; Mischler, S E
2016-01-01
Airborne coal dust mass measurements in underground bituminous coal mines can be challenged by the presence of airborne limestone dust, which is an incombustible dust applied to prevent the propagation of dust explosions. To accurately measure the coal portion of this mixed airborne dust, the National Institute for Occupational Safety and Health (NIOSH) developed a sampling and analysis protocol that used a stainless steel cassette adapted with an isokinetic inlet and the low temperature ashing (LTA) analytical method. The Mine Safety and Health Administration (MSHA) routinely utilizes this LTA method to quantify the incombustible content of bulk dust samples collected from the roof, floor, and ribs of mining entries. The use of the stainless steel cassette with isokinetic inlet allowed NIOSH to adopt the LTA method for the analysis of airborne dust samples. Mixtures of known coal and limestone dust masses were prepared in the laboratory, loaded into the stainless steel cassettes, and analyzed to assess the accuracy of this method. Coal dust mass measurements differed from predicted values by an average of 0.5%, 0.2%, and 0.1% for samples containing 20%, 91%, and 95% limestone dust, respectively. The ability of this method to accurately quantify the laboratory samples confirmed the validity of this method and allowed NIOSH to successfully measure the coal fraction of airborne dust samples collected in an underground coal mine.
Barone, T. L.; Patts, J. R.; Janisko, S. J.; Colinet, J. F.; Patts, L. D.; Beck, T. W.; Mischler, S. E.
2016-01-01
Airborne coal dust mass measurements in underground bituminous coal mines can be challenged by the presence of airborne limestone dust, which is an incombustible dust applied to prevent the propagation of dust explosions. To accurately measure the coal portion of this mixed airborne dust, the National Institute for Occupational Safety and Health (NIOSH) developed a sampling and analysis protocol that used a stainless steel cassette adapted with an isokinetic inlet and the low temperature ashing (LTA) analytical method. The Mine Safety and Health Administration (MSHA) routinely utilizes this LTA method to quantify the incombustible content of bulk dust samples collected from the roof, floor, and ribs of mining entries. The use of the stainless steel cassette with isokinetic inlet allowed NIOSH to adopt the LTA method for the analysis of airborne dust samples. Mixtures of known coal and limestone dust masses were prepared in the laboratory, loaded into the stainless steel cassettes, and analyzed to assess the accuracy of this method. Coal dust mass measurements differed from predicted values by an average of 0.5%, 0.2%, and 0.1% for samples containing 20%, 91%, and 95% limestone dust, respectively. The ability of this method to accurately quantify the laboratory samples confirmed the validity of this method and allowed NIOSH to successfully measure the coal fraction of airborne dust samples collected in an underground coal mine. PMID:26618374
Automated Coal-Mine Shuttle Car
NASA Technical Reports Server (NTRS)
Collins, E. R., Jr.
1984-01-01
Cable-guided car increases efficiency in underground coal mines. Unmanned vehicle contains storage batteries in side panels for driving traction motors located in wheels. Batteries recharged during inactive periods or slid out as unit and replaced by fresh battery bank. Onboard generator charges batteries as car operates.
30 CFR 784.20 - Subsidence control plan.
Code of Federal Regulations, 2010 CFR
2010-07-01
... COAL MINING AND RECLAMATION OPERATIONS PERMITS AND COAL EXPLORATION SYSTEMS UNDER REGULATORY PROGRAMS UNDERGROUND MINING PERMIT APPLICATIONS-MINIMUM REQUIREMENTS FOR RECLAMATION AND OPERATION PLAN § 784.20... 30 Mineral Resources 3 2010-07-01 2010-07-01 false Subsidence control plan. 784.20 Section 784.20...
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 3 2013-07-01 2013-07-01 false Road systems. 784.24 Section 784.24 Mineral... MINING AND RECLAMATION OPERATIONS PERMITS AND COAL EXPLORATION SYSTEMS UNDER REGULATORY PROGRAMS... systems. (a) Plans and drawings. Each applicant for an underground coal mining and reclamation permit...
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 3 2014-07-01 2014-07-01 false Road systems. 784.24 Section 784.24 Mineral... MINING AND RECLAMATION OPERATIONS PERMITS AND COAL EXPLORATION SYSTEMS UNDER REGULATORY PROGRAMS... systems. (a) Plans and drawings. Each applicant for an underground coal mining and reclamation permit...
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 3 2012-07-01 2012-07-01 false Road systems. 784.24 Section 784.24 Mineral... MINING AND RECLAMATION OPERATIONS PERMITS AND COAL EXPLORATION SYSTEMS UNDER REGULATORY PROGRAMS... systems. (a) Plans and drawings. Each applicant for an underground coal mining and reclamation permit...
30 CFR 75.1326 - Examination after blasting.
Code of Federal Regulations, 2010 CFR
2010-07-01
....1326 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Explosives and Blasting § 75.1326 Examination... and dust. (b) Immediately after the blasting area has cleared, a qualified person or a person working...
30 CFR 75.1722 - Mechanical equipment guards.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Mechanical equipment guards. 75.1722 Section 75.1722 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1722 Mechanical equipment...
30 CFR 75.1908 - Nonpermissible diesel-powered equipment; categories.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Nonpermissible diesel-powered equipment... LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Diesel-Powered Equipment § 75.1908 Nonpermissible diesel-powered equipment; categories. (a) Heavy-duty diesel-powered...
30 CFR 75.1908 - Nonpermissible diesel-powered equipment; categories.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Nonpermissible diesel-powered equipment... LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Diesel-Powered Equipment § 75.1908 Nonpermissible diesel-powered equipment; categories. (a) Heavy-duty diesel-powered...
30 CFR 75.1729 - Welding operations.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Welding operations. 75.1729 Section 75.1729 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1729 Welding operations. Welding...
30 CFR 75.322 - Harmful quantities of noxious gases.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Section 75.322 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Ventilation § 75.322 Harmful... Governmental Industrial Hygienists in “Threshold Limit Values for Substance in Workroom Air” (1972). Detectors...
30 CFR 75.322 - Harmful quantities of noxious gases.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Section 75.322 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Ventilation § 75.322 Harmful... Governmental Industrial Hygienists in “Threshold Limit Values for Substance in Workroom Air” (1972). Detectors...
30 CFR 75.1729 - Welding operations.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Welding operations. 75.1729 Section 75.1729 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1729 Welding operations. Welding...
30 CFR 75.1729 - Welding operations.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Welding operations. 75.1729 Section 75.1729 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1729 Welding operations. Welding...
30 CFR 75.1729 - Welding operations.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Welding operations. 75.1729 Section 75.1729 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1729 Welding operations. Welding...
30 CFR 75.1729 - Welding operations.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Welding operations. 75.1729 Section 75.1729 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1729 Welding operations. Welding...
30 CFR 75.382 - Mechanical escape facilities.
Code of Federal Regulations, 2011 CFR
2011-07-01
....382 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Ventilation § 75.382 Mechanical escape... shall be run through one complete cycle of operation to determine that it is operating properly. (d) A...
Ding, Xu; Shi, Lei; Han, Jianghong; Lu, Jingting
2016-01-01
Wireless sensor networks deployed in coal mines could help companies provide workers working in coal mines with more qualified working conditions. With the underground information collected by sensor nodes at hand, the underground working conditions could be evaluated more precisely. However, sensor nodes may tend to malfunction due to their limited energy supply. In this paper, we study the cross-layer optimization problem for wireless rechargeable sensor networks implemented in coal mines, of which the energy could be replenished through the newly-brewed wireless energy transfer technique. The main results of this article are two-fold: firstly, we obtain the optimal relay nodes’ placement according to the minimum overall energy consumption criterion through the Lagrange dual problem and KKT conditions; secondly, the optimal strategies for recharging locomotives and wireless sensor networks are acquired by solving a cross-layer optimization problem. The cyclic nature of these strategies is also manifested through simulations in this paper. PMID:26828500
Ding, Xu; Shi, Lei; Han, Jianghong; Lu, Jingting
2016-01-28
Wireless sensor networks deployed in coal mines could help companies provide workers working in coal mines with more qualified working conditions. With the underground information collected by sensor nodes at hand, the underground working conditions could be evaluated more precisely. However, sensor nodes may tend to malfunction due to their limited energy supply. In this paper, we study the cross-layer optimization problem for wireless rechargeable sensor networks implemented in coal mines, of which the energy could be replenished through the newly-brewed wireless energy transfer technique. The main results of this article are two-fold: firstly, we obtain the optimal relay nodes' placement according to the minimum overall energy consumption criterion through the Lagrange dual problem and KKT conditions; secondly, the optimal strategies for recharging locomotives and wireless sensor networks are acquired by solving a cross-layer optimization problem. The cyclic nature of these strategies is also manifested through simulations in this paper.
30 CFR 75.1200-1 - Additional information on mine map.
Code of Federal Regulations, 2010 CFR
2010-07-01
... SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Maps § 75.1200-1 Additional... symbols; (g) The location of railroad tracks and public highways leading to the mine, and mine buildings... permanent base line points coordinated with the underground and surface mine traverses, and the location and...
30 CFR 75.1901 - Diesel fuel requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Diesel fuel requirements. 75.1901 Section 75... HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Diesel-Powered Equipment § 75.1901 Diesel fuel requirements. (a) Diesel-powered equipment shall be used underground only with a diesel fuel having a sulfur...
30 CFR 75.1901 - Diesel fuel requirements.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Diesel fuel requirements. 75.1901 Section 75... HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Diesel-Powered Equipment § 75.1901 Diesel fuel requirements. (a) Diesel-powered equipment shall be used underground only with a diesel fuel having a sulfur...
Literature survey of properties of synfuels derived from coal
NASA Technical Reports Server (NTRS)
Flores, F.
1982-01-01
A literature survey of the properties of synfuels for ground-based turbine applications is presented. The four major concepts for converting coal into liquid fuels (solvent extraction, catalytic liquefaction, pyrolysis, and indirect liquefaction), and the most important concepts for coal gasification (fixed bed, fluidized bed, entrained flow, and underground gasification) are described. Upgrading processes for coal derived liquid fuels are also described. Data presented for liquid fuels derived from various processes, including H-coal, synthoil, solvent refined coal, COED, donor solvent, zinc chloride hydrocracking, co-steam, and flash pyrolysis. Typical composition, and property data is also presented for low and medium-BTU gases derived from the various coal gasification processes.
Biogenic coal-to-methane conversion efficiency decreases after repeated organic amendment
Davis, Katherine J.; Barnhart, Elliott P.; Fields, Matthew W.; Gerlach, Robin
2018-01-01
Addition of organic amendments to coal-containing systems can increase the rate and extent of biogenic methane production for 60–80 days before production slows or stops. Understanding the effect of repeated amendment additions on the rate and extent of enhanced coal-dependent methane production is important if biological coal-to-methane conversion is to be enhanced on a commercial scale. Microalgal biomass was added at a concentration of 0.1 g/L to microcosms with and without coal on days 0, 76, and 117. Rates of methane production were enhanced after the initial amendment but coal-containing treatments produced successively decreasing amounts of methane with each amendment. During the first amendment period, 113% of carbon added as amendment was recovered as methane, whereas in the second and third amendment periods, 39% and 32% of carbon added as amendment was recovered as methane, respectively. Additionally, algae-amended coal treatments produced ∼38% more methane than unamended coal treatments and ∼180% more methane than amended coal-free treatments after one amendment. However, a second amendment addition resulted in only an ∼25% increase in methane production for coal versus noncoal treatments and a third amendment addition resulted in similar methane production in both coal and noncoal treatments. Successive amendment additions appeared to result in a shift from coal-to-methane conversion to amendment-to-methane conversion. The reported results indicate that a better understanding is needed of the potential impacts and efficiencies of repeated stimulation for enhanced coal-to-methane conversion.
Application and Prospects of High-strength Lightweight Materials used in Coal mine
NASA Astrophysics Data System (ADS)
He, Pan
2017-09-01
This paper describes some high-strength lightweight materials used in coal mine, and if their performance can meet the requirements of underground safety for explosion-proof, anti-static, friction sparks mine; and reviewed the species, characteristic, preparation process of high-strength lightweight materials for having inspired lightweight high-strength performance by modifying or changing the synthesis mode used in coal mine equipment.
Underground coal miners' foot and boot problems.
Wood, G; Marr, S; Berry, G; Nubé, V; Cole, J
1999-11-01
The New South Wales (NSW) Joint Coal Board Health and Safety Trust funded an investigation into foot problems reported by 400 randomly selected underground coal miners from 15 mines in NSW. Miners were interviewed and their responses were entered directly into laptop computers. Digital cameras were also used to take pictures of skin conditions and miners' posture. Observations of the skin results indicate that miners find gumboots to be hot, sweaty and uncomfortable. Skin breakdown and tinea, is frequent and disabling and responsible for absences from the workforce that are costly for both miner and employer. A more comfortable and better designed boot is needed, fabricated in waterproof leather together with socks that 'wick' the moisture away from the foot. Socks worn were of varying components and washed at irregular intervals, indicating a need for regular changes of socks and improved hygiene.
Detecting and characterizing coal mine related seismicity in the Western U.S. using subspace methods
NASA Astrophysics Data System (ADS)
Chambers, Derrick J. A.; Koper, Keith D.; Pankow, Kristine L.; McCarter, Michael K.
2015-11-01
We present an approach for subspace detection of small seismic events that includes methods for estimating magnitudes and associating detections from multiple stations into unique events. The process is used to identify mining related seismicity from a surface coal mine and an underground coal mining district, both located in the Western U.S. Using a blasting log and a locally derived seismic catalogue as ground truth, we assess detector performance in terms of verified detections, false positives and failed detections. We are able to correctly identify over 95 per cent of the surface coal mine blasts and about 33 per cent of the events from the underground mining district, while keeping the number of potential false positives relatively low by requiring all detections to occur on two stations. We find that most of the potential false detections for the underground coal district are genuine events missed by the local seismic network, demonstrating the usefulness of regional subspace detectors in augmenting local catalogues. We note a trade-off in detection performance between stations at smaller source-receiver distances, which have increased signal-to-noise ratio, and stations at larger distances, which have greater waveform similarity. We also explore the increased detection capabilities of a single higher dimension subspace detector, compared to multiple lower dimension detectors, in identifying events that can be described as linear combinations of training events. We find, in our data set, that such an advantage can be significant, justifying the use of a subspace detection scheme over conventional correlation methods.
Characteristics of coal mine ventilation air flows.
Su, Shi; Chen, Hongwei; Teakle, Philip; Xue, Sheng
2008-01-01
Coal mine methane (CMM) is not only a greenhouse gas but also a wasted energy resource if not utilised. Underground coal mining is by far the most important source of fugitive methane emissions, and approximately 70% of all coal mining related methane is emitted to the atmosphere through mine ventilation air. Therefore, research and development on mine methane mitigation and utilisation now focuses on methane emitted from underground coal mines, in particular ventilation air methane (VAM) capture and utilisation. To date, most work has focused on the oxidation of very low concentration methane. These processes may be classified based on their combustion kinetic mechanisms into thermal oxidation and catalytic oxidation. VAM mitigation/utilisation technologies are generally divided into two basic categories: ancillary uses and principal uses. However, it is possible that the characteristics of ventilation air flows, for example the variations in methane concentration and the presence of certain compounds, which have not been reported so far, could make some potential VAM mitigation and utilisation technologies unfeasible if they cannot cope with the characteristics of mine site ventilation air flows. Therefore, it is important to understand the characteristics of mine ventilation air flows. Moreover, dust, hydrogen sulphide, sulphur dioxide, and other possible compounds emitted through mine ventilation air into the atmosphere are also pollutants. Therefore, this paper presents mine-site experimental results on the characteristics of mine ventilation air flows, including methane concentration and its variations, dust loadings, particle size, mineral matter of the dust, and other compounds in the ventilation air flows. The paper also discusses possible correlations between ventilation air characteristics and underground mining activities.
30 CFR 75.600 - Trailing cables; flame resistance.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Trailing cables; flame resistance. 75.600... SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Trailing Cables § 75.600 Trailing cables; flame resistance. [Statutory Provisions] Trailing cables used in coal mines shall meet the...
30 CFR 75.404 - Exemption of anthracite mines.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Exemption of anthracite mines. 75.404 Section 75.404 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Combustible Materials and Rock Dusting...
30 CFR 75.404 - Exemption of anthracite mines.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Exemption of anthracite mines. 75.404 Section 75.404 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Combustible Materials and Rock Dusting...
30 CFR 75.404 - Exemption of anthracite mines.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Exemption of anthracite mines. 75.404 Section 75.404 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Combustible Materials and Rock Dusting...
30 CFR 75.404 - Exemption of anthracite mines.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Exemption of anthracite mines. 75.404 Section 75.404 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Combustible Materials and Rock Dusting...
30 CFR 75.404 - Exemption of anthracite mines.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Exemption of anthracite mines. 75.404 Section 75.404 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Combustible Materials and Rock Dusting...
Code of Federal Regulations, 2011 CFR
2011-07-01
... is located. (g) MRE instrument means the gravimetric dust sampler with a four channel horizontal... in the earth by any means or method, and the work of preparing the coal so extracted, including... bituminous coal, lignite, or anthracite from its natural deposits underground by any means or method, and the...
30 CFR 77.1435 - Load end attachments.
Code of Federal Regulations, 2010 CFR
2010-07-01
... MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES Personnel... where use of other materials is a design feature, zinc (spelter) shall be used for socketing wire ropes. Design feature means either the manufacturer's original design or a design approved by a registered...
30 CFR 77.503-1 - Electric conductors.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Cable Engineers Association—National Electric Manufacturers Association in effect when such cables are... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Electric conductors. 77.503-1 Section 77.503-1... MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES Electrical...
30 CFR 77.503-1 - Electric conductors.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Cable Engineers Association—National Electric Manufacturers Association in effect when such cables are... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Electric conductors. 77.503-1 Section 77.503-1... MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES Electrical...
30 CFR 77.503-1 - Electric conductors.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Cable Engineers Association—National Electric Manufacturers Association in effect when such cables are... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Electric conductors. 77.503-1 Section 77.503-1... MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES Electrical...
30 CFR 77.503-1 - Electric conductors.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Cable Engineers Association—National Electric Manufacturers Association in effect when such cables are... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Electric conductors. 77.503-1 Section 77.503-1... MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES Electrical...
30 CFR 77.503-1 - Electric conductors.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Cable Engineers Association—National Electric Manufacturers Association in effect when such cables are... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Electric conductors. 77.503-1 Section 77.503-1... MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES Electrical...
30 CFR 77.1000 - Highwalls, pits and spoil banks; plans.
Code of Federal Regulations, 2010 CFR
2010-07-01
... safe working conditions. The mining methods employed by the operator shall be selected to insure... Section 77.1000 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND...
Code of Federal Regulations, 2013 CFR
2013-07-01
... Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Ventilation § 75.301 Definitions. In addition to the applicable... operator. The person(s), designated by the mine operator, who is located on the surface of the mine and...
Code of Federal Regulations, 2014 CFR
2014-07-01
... Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Ventilation § 75.301 Definitions. In addition to the applicable... operator. The person(s), designated by the mine operator, who is located on the surface of the mine and...
30 CFR 70.209 - Respirable dust samples; transmission by operator.
Code of Federal Regulations, 2014 CFR
2014-07-01
... operator. 70.209 Section 70.209 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-UNDERGROUND COAL MINES Sampling Procedures... Laboratory, Pittsburgh Safety and Health Technology Center, Cochran Mill Road, Building 38, P.O. Box 18179...
30 CFR 70.209 - Respirable dust samples; transmission by operator.
Code of Federal Regulations, 2013 CFR
2013-07-01
... operator. 70.209 Section 70.209 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-UNDERGROUND COAL MINES Sampling Procedures... Laboratory, Pittsburgh Safety and Health Technology Center, Cochran Mill Road, Building 38, P.O. Box 18179...
Code of Federal Regulations, 2012 CFR
2012-07-01
... Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Ventilation § 75.301 Definitions. In addition to the applicable... operator. The person(s), designated by the mine operator, who is located on the surface of the mine and...
30 CFR 70.209 - Respirable dust samples; transmission by operator.
Code of Federal Regulations, 2012 CFR
2012-07-01
... operator. 70.209 Section 70.209 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-UNDERGROUND COAL MINES Sampling Procedures... Laboratory, Pittsburgh Safety and Health Technology Center, Cochran Mill Road, Building 38, P.O. Box 18179...
30 CFR 70.220 - Status change reports.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-UNDERGROUND COAL MINES Sampling Procedures § 70.220 Status change reports. (a) If there is a change in operational status that affects the respirable dust sampling requirements of this...
30 CFR 77.1601 - Transportation of persons; restrictions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Transportation of persons; restrictions. 77.1601 Section 77.1601 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL... UNDERGROUND COAL MINES Loading and Haulage § 77.1601 Transportation of persons; restrictions. No person shall...
30 CFR 77.1104 - Accumulations of combustible materials.
Code of Federal Regulations, 2013 CFR
2013-07-01
..., grease, lubricants, paints, or flammable liquids shall not be allowed to accumulate where they can create... Section 77.1104 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND...
30 CFR 77.1104 - Accumulations of combustible materials.
Code of Federal Regulations, 2014 CFR
2014-07-01
..., grease, lubricants, paints, or flammable liquids shall not be allowed to accumulate where they can create... Section 77.1104 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND...
30 CFR 77.1104 - Accumulations of combustible materials.
Code of Federal Regulations, 2011 CFR
2011-07-01
..., grease, lubricants, paints, or flammable liquids shall not be allowed to accumulate where they can create... Section 77.1104 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND...
30 CFR 77.1104 - Accumulations of combustible materials.
Code of Federal Regulations, 2012 CFR
2012-07-01
..., grease, lubricants, paints, or flammable liquids shall not be allowed to accumulate where they can create... Section 77.1104 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND...
30 CFR 77.1104 - Accumulations of combustible materials.
Code of Federal Regulations, 2010 CFR
2010-07-01
..., grease, lubricants, paints, or flammable liquids shall not be allowed to accumulate where they can create... Section 77.1104 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND...
30 CFR 77.1601 - Transportation of persons; restrictions.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Transportation of persons; restrictions. 77.1601 Section 77.1601 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL... UNDERGROUND COAL MINES Loading and Haulage § 77.1601 Transportation of persons; restrictions. No person shall...
30 CFR 77.1601 - Transportation of persons; restrictions.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Transportation of persons; restrictions. 77.1601 Section 77.1601 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL... UNDERGROUND COAL MINES Loading and Haulage § 77.1601 Transportation of persons; restrictions. No person shall...
30 CFR 77.1601 - Transportation of persons; restrictions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Transportation of persons; restrictions. 77.1601 Section 77.1601 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL... UNDERGROUND COAL MINES Loading and Haulage § 77.1601 Transportation of persons; restrictions. No person shall...
30 CFR 77.1601 - Transportation of persons; restrictions.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Transportation of persons; restrictions. 77.1601 Section 77.1601 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL... UNDERGROUND COAL MINES Loading and Haulage § 77.1601 Transportation of persons; restrictions. No person shall...
30 CFR 75.1728 - Power-driven pulleys.
Code of Federal Regulations, 2010 CFR
2010-07-01
... hands except on slow-moving equipment especially designed for hand feeding. (b) Pulleys of conveyors shall not be cleaned manually while the conveyor is in motion. (c) Coal spilled beneath belt conveyor... MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1728 Power-driven pulleys. (a) Belts...
30 CFR 75.1434 - Retirement criteria.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Hoisting and Mantrips Wire Ropes § 75.1434 Retirement... structure; (f) Heat damage from any source; (g) Diameter reduction due to wear that exceeds six percent of...
30 CFR 75.1404-1 - Braking system.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Hoisting and Mantrips § 75.1404-1 Braking system. A... limits of its design capabilities and at speeds consistent with the condition of the haulage road. A...
30 CFR 75.1404-1 - Braking system.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Hoisting and Mantrips § 75.1404-1 Braking system. A... limits of its design capabilities and at speeds consistent with the condition of the haulage road. A...
30 CFR 77.1801-1 - Devices for overcurrent protection.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Section 77.1801-1 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND... circuit at any point in the system will meet the requirements of § 77.1801. ...
30 CFR 75.389 - Mining into inaccessible areas.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Mining into inaccessible areas. 75.389 Section 75.389 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Ventilation § 75.389 Mining into...
30 CFR 75.389 - Mining into inaccessible areas.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Mining into inaccessible areas. 75.389 Section 75.389 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Ventilation § 75.389 Mining into...
Sunrise coal, an innovative New Indiana player continues to grow
DOE Office of Scientific and Technical Information (OSTI.GOV)
Buchsbaum, L.
2009-07-15
Sunrise Coal LLC's Carliste (Indiana) underground mine began development in 2006. Today, the room and pillar operation has grown to a 3 million tpy four unit continuous miner mine. Its coal has low (0.06%) chlorine level and is now being purchased to blend down high chlorine in Illinois Basin coal. The article describes the mining operation and equipment traces the growth of the company, founded in the 1970s by Row and Steve Laswell, emphasizing its focus on employee safety. 5 photos.
Underground Coal Thermal Treatment: Task 6 Topical Report, Utah Clean Coal Program
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, P.J.; Deo, M.; Edding, E.G.
The long-term objective of this task is to develop a transformational energy production technology by in- situ thermal treatment of a coal seam for the production of substitute natural gas and/or liquid transportation fuels while leaving much of the coal’s carbon in the ground. This process converts coal to a high-efficiency, low-greenhouse gas (GHG) emitting fuel. It holds the potential of providing environmentally acceptable access to previously unusable coal resources. This task focused on three areas: Experimental. The Underground Coal Thermal Treatment (UCTT) team focused on experiments at two scales, bench-top and slightly larger, to develop data to understand themore » feasibility of a UCTT process as well as to develop validation/uncertainty quantification (V/UQ) data for the simulation team. Simulation. The investigators completed development of High Performance Computing (HPC) simulations of UCTT. This built on our simulation developments over the course of the task and included the application of Computational Fluid Dynamics (CFD)- based tools to perform HPC simulations of a realistically sized domain representative of an actual coal field located in Utah. CO 2 storage. In order to help determine the amount of CO 2 that can be sequestered in a coal formation that has undergone UCTT, adsorption isotherms were performed on coals treated to 325, 450, and 600°C with slow heating rates. Raw material was sourced from the Sufco (Utah), Carlinville (Illinois), and North Antelope (Wyoming) mines. The study indicated that adsorptive capacity for the coals increased with treatment temperature and that coals treated to 325°C showed less or similar capacity to the untreated coals.« less
Kapusta, Krzysztof; Stańczyk, Krzysztof
2015-02-01
The effect of coal rank on the composition and toxicity of water effluents resulting from two underground coal gasification experiments with distinct coal samples (lignite and hard coal) was investigated. A broad range of organic and inorganic parameters was determined in the sampled condensates. The physicochemical tests were supplemented by toxicity bioassays based on the luminescent bacteria Vibrio fischeri as the test organism. The principal component analysis and Pearson correlation analysis were adopted to assist in the interpretation of the raw experimental data, and the multiple regression statistical method was subsequently employed to enable predictions of the toxicity based on the values of the selected parameters. Significant differences in the qualitative and quantitative description of the contamination profiles were identified for both types of coal under study. Independent of the coal rank, the most characteristic organic components of the studied condensates were phenols, naphthalene and benzene. In the inorganic array, ammonia, sulphates and selected heavy metals and metalloids were identified as the dominant constituents. Except for benzene with its alkyl homologues (BTEX), selected polycyclic aromatic hydrocarbons (PAHs), zinc and selenium, the values of the remaining parameters were considerably greater for the hard coal condensates. The studies revealed that all of the tested UCG condensates were extremely toxic to V. fischeri; however, the average toxicity level for the hard coal condensates was approximately 56% higher than that obtained for the lignite. The statistical analysis provided results supporting that the toxicity of the condensates was most positively correlated with the concentrations of free ammonia, phenols and certain heavy metals. Copyright © 2014 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
Gulf Research and Development Company is implementing a DOE-sponsored Underground Coal Gasification project in Steeply Dipping Coal Beds (UCG/SDB) in order to assess the economic and technical viability of UCG in SDB. In the Fall 1980 drilling program, 2 vertical and 2 slant process wells; 3 hydrologic and 1 exploratory well and 4 HFEM wells were completed. The Spring, 1981 program will consist of drilling the remaining instrumentation wells necessary to track the progress of the underground reactor in real time. These will consist of: 6 additional High Frequency Electromagnetic wells (HFEM) and 3 extensometer wells (X). These wells willmore » be installed vertically with an expected deviation of two degrees or less.« less
Anchor-Free Localization Method for Mobile Targets in Coal Mine Wireless Sensor Networks
Pei, Zhongmin; Deng, Zhidong; Xu, Shuo; Xu, Xiao
2009-01-01
Severe natural conditions and complex terrain make it difficult to apply precise localization in underground mines. In this paper, an anchor-free localization method for mobile targets is proposed based on non-metric multi-dimensional scaling (Multi-dimensional Scaling: MDS) and rank sequence. Firstly, a coal mine wireless sensor network is constructed in underground mines based on the ZigBee technology. Then a non-metric MDS algorithm is imported to estimate the reference nodes’ location. Finally, an improved sequence-based localization algorithm is presented to complete precise localization for mobile targets. The proposed method is tested through simulations with 100 nodes, outdoor experiments with 15 ZigBee physical nodes, and the experiments in the mine gas explosion laboratory with 12 ZigBee nodes. Experimental results show that our method has better localization accuracy and is more robust in underground mines. PMID:22574048
Anchor-free localization method for mobile targets in coal mine wireless sensor networks.
Pei, Zhongmin; Deng, Zhidong; Xu, Shuo; Xu, Xiao
2009-01-01
Severe natural conditions and complex terrain make it difficult to apply precise localization in underground mines. In this paper, an anchor-free localization method for mobile targets is proposed based on non-metric multi-dimensional scaling (Multi-dimensional Scaling: MDS) and rank sequence. Firstly, a coal mine wireless sensor network is constructed in underground mines based on the ZigBee technology. Then a non-metric MDS algorithm is imported to estimate the reference nodes' location. Finally, an improved sequence-based localization algorithm is presented to complete precise localization for mobile targets. The proposed method is tested through simulations with 100 nodes, outdoor experiments with 15 ZigBee physical nodes, and the experiments in the mine gas explosion laboratory with 12 ZigBee nodes. Experimental results show that our method has better localization accuracy and is more robust in underground mines.
Energy conversion alternatives study
NASA Technical Reports Server (NTRS)
Shure, L. T.
1979-01-01
Comparison of coal based energy systems is given. Study identifies and compares various advanced energy conversion systems using coal or coal derived fuels for baselaoad electric power generation. Energy Conversion Alternatives Study (ECAS) reports provede government, industry, and general public with technically consistent basis for comparison of system's options of interest for fossilfired electric-utility application.
Geologic considerations in underground coal mining system design
NASA Technical Reports Server (NTRS)
Camilli, F. A.; Maynard, D. P.; Mangolds, A.; Harris, J.
1981-01-01
Geologic characteristics of coal resources which may impact new extraction technologies are identified and described to aid system designers and planners in their task of designing advanced coal extraction systems for the central Appalachian region. These geologic conditions are then organized into a matrix identified as the baseline mine concept. A sample region, eastern Kentucy is analyzed using both the developed baseline mine concept and the traditional geologic investigative approach.
30 CFR 75.703-1 - Approved method of grounding.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Approved method of grounding. 75.703-1 Section 75.703-1 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Grounding § 75.703-1 Approved method...
30 CFR 75.703-1 - Approved method of grounding.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Approved method of grounding. 75.703-1 Section 75.703-1 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Grounding § 75.703-1 Approved method...
30 CFR 75.703-1 - Approved method of grounding.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Approved method of grounding. 75.703-1 Section 75.703-1 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Grounding § 75.703-1 Approved method...
30 CFR 77.603 - Clamping of trailing cables to equipment.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Clamping of trailing cables to equipment. 77.603 Section 77.603 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL... UNDERGROUND COAL MINES Trailing Cables § 77.603 Clamping of trailing cables to equipment. Trailing cables...
30 CFR 75.600-1 - Approved cables; flame resistance.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Approved cables; flame resistance. 75.600-1 Section 75.600-1 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Trailing Cables § 75.600-1 Approved...
30 CFR 75.607 - Breaking trailing cable and power cable connections.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Breaking trailing cable and power cable... LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Trailing Cables § 75.607 Breaking trailing cable and power cable connections. [Statutory Provisions] Trailing cable and...
30 CFR 77.1000 - Highwalls, pits and spoil banks; plans.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Section 77.1000 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND... developed after June 30, 1971, which shall be consistent with prudent engineering design and will insure...
30 CFR 77.1000 - Highwalls, pits and spoil banks; plans.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Section 77.1000 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND... developed after June 30, 1971, which shall be consistent with prudent engineering design and will insure...
30 CFR 77.1000 - Highwalls, pits and spoil banks; plans.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Section 77.1000 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND... developed after June 30, 1971, which shall be consistent with prudent engineering design and will insure...
30 CFR 77.1000 - Highwalls, pits and spoil banks; plans.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Section 77.1000 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND... developed after June 30, 1971, which shall be consistent with prudent engineering design and will insure...
30 CFR 71.400 - Bathing facilities; change rooms; sanitary flush toilet facilities.
Code of Federal Regulations, 2012 CFR
2012-07-01
... WORK AREAS OF UNDERGROUND COAL MINES Surface Bathing Facilities, Change Rooms, and Sanitary Flush Toilet Facilities at Surface Coal Mines § 71.400 Bathing facilities; change rooms; sanitary flush toilet... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Bathing facilities; change rooms; sanitary...
30 CFR 71.400 - Bathing facilities; change rooms; sanitary flush toilet facilities.
Code of Federal Regulations, 2013 CFR
2013-07-01
... WORK AREAS OF UNDERGROUND COAL MINES Surface Bathing Facilities, Change Rooms, and Sanitary Flush Toilet Facilities at Surface Coal Mines § 71.400 Bathing facilities; change rooms; sanitary flush toilet... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Bathing facilities; change rooms; sanitary...
30 CFR 71.403 - Waiver of surface facilities requirements; posting of waiver.
Code of Federal Regulations, 2014 CFR
2014-07-01
... WORK AREAS OF UNDERGROUND COAL MINES Surface Bathing Facilities, Change Rooms, and Sanitary Flush Toilet Facilities at Surface Coal Mines § 71.403 Waiver of surface facilities requirements; posting of... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Waiver of surface facilities requirements...
30 CFR 71.403 - Waiver of surface facilities requirements; posting of waiver.
Code of Federal Regulations, 2012 CFR
2012-07-01
... WORK AREAS OF UNDERGROUND COAL MINES Surface Bathing Facilities, Change Rooms, and Sanitary Flush Toilet Facilities at Surface Coal Mines § 71.403 Waiver of surface facilities requirements; posting of... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Waiver of surface facilities requirements...
30 CFR 71.403 - Waiver of surface facilities requirements; posting of waiver.
Code of Federal Regulations, 2013 CFR
2013-07-01
... WORK AREAS OF UNDERGROUND COAL MINES Surface Bathing Facilities, Change Rooms, and Sanitary Flush Toilet Facilities at Surface Coal Mines § 71.403 Waiver of surface facilities requirements; posting of... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Waiver of surface facilities requirements...
30 CFR 71.400 - Bathing facilities; change rooms; sanitary flush toilet facilities.
Code of Federal Regulations, 2014 CFR
2014-07-01
... WORK AREAS OF UNDERGROUND COAL MINES Surface Bathing Facilities, Change Rooms, and Sanitary Flush Toilet Facilities at Surface Coal Mines § 71.400 Bathing facilities; change rooms; sanitary flush toilet... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Bathing facilities; change rooms; sanitary...
30 CFR 71.404 - Application for waiver of surface facilities requirements.
Code of Federal Regulations, 2013 CFR
2013-07-01
... OF UNDERGROUND COAL MINES Surface Bathing Facilities, Change Rooms, and Sanitary Flush Toilet Facilities at Surface Coal Mines § 71.404 Application for waiver of surface facilities requirements. (a... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Application for waiver of surface facilities...
30 CFR 71.403 - Waiver of surface facilities requirements; posting of waiver.
Code of Federal Regulations, 2011 CFR
2011-07-01
... WORK AREAS OF UNDERGROUND COAL MINES Surface Bathing Facilities, Change Rooms, and Sanitary Flush Toilet Facilities at Surface Coal Mines § 71.403 Waiver of surface facilities requirements; posting of... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Waiver of surface facilities requirements...
30 CFR 71.400 - Bathing facilities; change rooms; sanitary flush toilet facilities.
Code of Federal Regulations, 2011 CFR
2011-07-01
... WORK AREAS OF UNDERGROUND COAL MINES Surface Bathing Facilities, Change Rooms, and Sanitary Flush Toilet Facilities at Surface Coal Mines § 71.400 Bathing facilities; change rooms; sanitary flush toilet... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Bathing facilities; change rooms; sanitary...
30 CFR 71.404 - Application for waiver of surface facilities requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... OF UNDERGROUND COAL MINES Surface Bathing Facilities, Change Rooms, and Sanitary Flush Toilet Facilities at Surface Coal Mines § 71.404 Application for waiver of surface facilities requirements. (a... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Application for waiver of surface facilities...
30 CFR 71.404 - Application for waiver of surface facilities requirements.
Code of Federal Regulations, 2012 CFR
2012-07-01
... OF UNDERGROUND COAL MINES Surface Bathing Facilities, Change Rooms, and Sanitary Flush Toilet Facilities at Surface Coal Mines § 71.404 Application for waiver of surface facilities requirements. (a... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Application for waiver of surface facilities...
30 CFR 71.404 - Application for waiver of surface facilities requirements.
Code of Federal Regulations, 2014 CFR
2014-07-01
... OF UNDERGROUND COAL MINES Surface Bathing Facilities, Change Rooms, and Sanitary Flush Toilet Facilities at Surface Coal Mines § 71.404 Application for waiver of surface facilities requirements. (a... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Application for waiver of surface facilities...
30 CFR 75.400-2 - Cleanup program.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Cleanup program. 75.400-2 Section 75.400-2 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Combustible Materials and Rock Dusting § 75.400-2 Cleanup...
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Exceptions. 75.402-2 Section 75.402-2 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Combustible Materials and Rock Dusting § 75.402-2 Exceptions...
30 CFR 75.400-2 - Cleanup program.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Cleanup program. 75.400-2 Section 75.400-2 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Combustible Materials and Rock Dusting § 75.400-2 Cleanup...
30 CFR 75.400-2 - Cleanup program.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Cleanup program. 75.400-2 Section 75.400-2 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Combustible Materials and Rock Dusting § 75.400-2 Cleanup...
30 CFR 75.400-2 - Cleanup program.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Cleanup program. 75.400-2 Section 75.400-2 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Combustible Materials and Rock Dusting § 75.400-2 Cleanup...
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Definition. 75.402-1 Section 75.402-1 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Combustible Materials and Rock Dusting § 75.402-1 Definition. The...
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Definition. 75.402-1 Section 75.402-1 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Combustible Materials and Rock Dusting § 75.402-1 Definition. The...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Definition. 75.402-1 Section 75.402-1 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Combustible Materials and Rock Dusting § 75.402-1 Definition. The...
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Definition. 75.402-1 Section 75.402-1 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Combustible Materials and Rock Dusting § 75.402-1 Definition. The...
30 CFR 75.401-1 - Excessive amounts of dust.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Excessive amounts of dust. 75.401-1 Section 75.401-1 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Combustible Materials and Rock Dusting...