40 CFR 279.22 - Used oil storage.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 27 2014-07-01 2014-07-01 false Used oil storage. 279.22 Section 279...) STANDARDS FOR THE MANAGEMENT OF USED OIL Standards for Used Oil Generators § 279.22 Used oil storage. Used... Underground Storage Tank (40 CFR part 280) standards for used oil stored in underground tanks whether or not...
40 CFR 279.22 - Used oil storage.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 28 2012-07-01 2012-07-01 false Used oil storage. 279.22 Section 279...) STANDARDS FOR THE MANAGEMENT OF USED OIL Standards for Used Oil Generators § 279.22 Used oil storage. Used... Underground Storage Tank (40 CFR part 280) standards for used oil stored in underground tanks whether or not...
40 CFR 279.22 - Used oil storage.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 28 2013-07-01 2013-07-01 false Used oil storage. 279.22 Section 279...) STANDARDS FOR THE MANAGEMENT OF USED OIL Standards for Used Oil Generators § 279.22 Used oil storage. Used... Underground Storage Tank (40 CFR part 280) standards for used oil stored in underground tanks whether or not...
40 CFR 279.64 - Used oil storage.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 28 2013-07-01 2013-07-01 false Used oil storage. 279.64 Section 279... for Energy Recovery § 279.64 Used oil storage. Used oil burners are subject to all applicable Spill.... Used oil burners are also subject to the Underground Storage Tank (40 CFR part 280) standards for used...
40 CFR 279.64 - Used oil storage.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 27 2014-07-01 2014-07-01 false Used oil storage. 279.64 Section 279... for Energy Recovery § 279.64 Used oil storage. Used oil burners are subject to all applicable Spill.... Used oil burners are also subject to the Underground Storage Tank (40 CFR part 280) standards for used...
40 CFR 279.64 - Used oil storage.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 28 2012-07-01 2012-07-01 false Used oil storage. 279.64 Section 279... for Energy Recovery § 279.64 Used oil storage. Used oil burners are subject to all applicable Spill.... Used oil burners are also subject to the Underground Storage Tank (40 CFR part 280) standards for used...
40 CFR 282.83 - North Carolina State-Administered Program.
Code of Federal Regulations, 2010 CFR
2010-07-01
... (Insofar as .94A(2) subjects certain heating oil tanks and the piping connected to otherwise excluded tanks... WASTES (CONTINUED) APPROVED UNDERGROUND STORAGE TANK PROGRAMS Approved State Programs § 282.83 North... an underground storage tank program in lieu of the Federal program under subtitle I of the Resource...
Underground storage systems for high-pressure air and gases
NASA Technical Reports Server (NTRS)
Beam, B. H.; Giovannetti, A.
1975-01-01
This paper is a discussion of the safety and cost of underground high-pressure air and gas storage systems based on recent experience with a high-pressure air system installed at Moffett Field, California. The system described used threaded and coupled oil well casings installed vertically to a depth of 1200 ft. Maximum pressure was 3000 psi and capacity was 500,000 lb of air. A failure mode analysis is presented, and it is shown that underground storage offers advantages in avoiding catastrophic consequences from pressure vessel failure. Certain problems such as corrosion, fatigue, and electrolysis are discussed in terms of the economic life of such vessels. A cost analysis shows that where favorable drilling conditions exist, the cost of underground high-pressure storage is approximately one-quarter that of equivalent aboveground storage.
Installation Restoration Program Records Search for Langley Air Force Base, Virginia
1982-06-01
Septic Tanks at Langley Air Force Base 12 Location of Oil /Water Separators at Langley Air Force Base 13 Location Map of Possible Contaminated Area at...No. J.) and old vehicle dumping area (Site No. 15). A-17 Location of old underground fuel lines--possible oil -saturated area. vi FIGURES--Continued A...18 Location of old wastewater treatment plant at the Main Base Area (Site No. 2). A-19 Location of old underground oil storage tanks-possible oil
30 CFR 57.8520 - Ventilation plan.
Code of Federal Regulations, 2010 CFR
2010-07-01
... mine openings adjacent to the mine; (9) Locations of permanent underground shops, diesel fuel storage depots, oil fuel storage depots, hoist rooms, compressors, battery charging stations and explosive...
Reducing drinking water supply chemical contamination: risks from underground storage tanks.
Enander, Richard T; Hanumara, R Choudary; Kobayashi, Hisanori; Gagnon, Ronald N; Park, Eugene; Vallot, Christopher; Genovesi, Richard
2012-12-01
Drinking water supplies are at risk of contamination from a variety of physical, chemical, and biological sources. Ranked among these threats are hazardous material releases from leaking or improperly managed underground storage tanks located at municipal, commercial, and industrial facilities. To reduce human health and environmental risks associated with the subsurface storage of hazardous materials, government agencies have taken a variety of legislative and regulatory actions--which date back more than 25 years and include the establishment of rigorous equipment/technology/operational requirements and facility-by-facility inspection and enforcement programs. Given a history of more than 470,000 underground storage tank releases nationwide, the U.S. Environmental Protection Agency continues to report that 7,300 new leaks were found in federal fiscal year 2008, while nearly 103,000 old leaks remain to be cleaned up. In this article, we report on an alternate evidence-based intervention approach for reducing potential releases from the storage of petroleum products (gasoline, diesel, kerosene, heating/fuel oil, and waste oil) in underground tanks at commercial facilities located in Rhode Island. The objective of this study was to evaluate whether a new regulatory model can be used as a cost-effective alternative to traditional facility-by-facility inspection and enforcement programs for underground storage tanks. We conclude that the alternative model, using an emphasis on technical assistance tools, can produce measurable improvements in compliance performance, is a cost-effective adjunct to traditional facility-by-facility inspection and enforcement programs, and has the potential to allow regulatory agencies to decrease their frequency of inspections among low risk facilities without sacrificing compliance performance or increasing public health risks. © 2012 Society for Risk Analysis.
High temperature underground thermal energy storage system for solar energy
NASA Technical Reports Server (NTRS)
Collins, R. E.
1980-01-01
The activities feasibility of high temperature underground thermal storage of energy was investigated. Results indicate that salt cavern storage of hot oil is both technically and economically feasible as a method of storing huge quantities of heat at relatively low cost. One particular system identified utilizes a gravel filled cavern leached within a salt dome. Thermal losses are shown to be less than one percent of cyclically transferred heat. A system like this having a 40 MW sub t transfer rate capability and over eight hours of storage capacity is shown to cost about $13.50 per KWh sub t.
30 CFR 57.4462 - Storage of combustible liquids underground.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Fire Prevention and Control Flammable and Combustible Liquids and Gases § 57.4462 Storage of...) Combustible liquids, including oil or grease, shall be stored in non-glass containers or storage tanks. The... one inch of shotcrete, one-half inch of gunite, or other noncombustible material with equivalent fire...
30 CFR 57.4462 - Storage of combustible liquids underground.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Fire Prevention and Control Flammable and Combustible Liquids and Gases § 57.4462 Storage of...) Combustible liquids, including oil or grease, shall be stored in non-glass containers or storage tanks. The... one inch of shotcrete, one-half inch of gunite, or other noncombustible material with equivalent fire...
30 CFR 57.4462 - Storage of combustible liquids underground.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Fire Prevention and Control Flammable and Combustible Liquids and Gases § 57.4462 Storage of...) Combustible liquids, including oil or grease, shall be stored in non-glass containers or storage tanks. The... one inch of shotcrete, one-half inch of gunite, or other noncombustible material with equivalent fire...
30 CFR 57.4462 - Storage of combustible liquids underground.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Fire Prevention and Control Flammable and Combustible Liquids and Gases § 57.4462 Storage of...) Combustible liquids, including oil or grease, shall be stored in non-glass containers or storage tanks. The... one inch of shotcrete, one-half inch of gunite, or other noncombustible material with equivalent fire...
30 CFR 57.4462 - Storage of combustible liquids underground.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Fire Prevention and Control Flammable and Combustible Liquids and Gases § 57.4462 Storage of...) Combustible liquids, including oil or grease, shall be stored in non-glass containers or storage tanks. The... one inch of shotcrete, one-half inch of gunite, or other noncombustible material with equivalent fire...
Storage of Residual Fuel Oil in Underground Unlined Rock Caverns.
1980-12-01
underground space as the above-mentioned companies.) These companies are anxious to market their experience and cite contacts with the U.S. Department of...expanding marketing efforts. Detailed descriptions 13. In the original plan for producing a generic study of the four storage media, it was decided to...Jollanssonr and Mr. Tuomlo SaarniI Manager, Market ing Energy Sector (Bibl: 14, 15, arid 16). 13 . Ekono Oy is one ol the four companies forming the
Research Progress in Carbon Dioxide Storage and Enhanced Oil Recovery
NASA Astrophysics Data System (ADS)
Wang, Keliang; Wang, Gang; Lu, Chunjing
2018-02-01
With the rapid development of global economy, human beings have become highly dependent upon fossil fuel such as coal and petroleum. Much fossil fuel is consumed in industrial production and human life. As a result, carbon dioxide emissions have been increasing, and the greenhouse effects thereby generated are posing serious threats to environment of the earth. These years, increasing average global temperature, frequent extreme weather events and climatic changes cause material disasters to the world. After scientists’ long-term research, ample evidences have proven that emissions of greenhouse gas like carbon dioxide have brought about tremendous changes to global climate. To really reduce carbon dioxide emissions, governments of different countries and international organizations have invested much money and human resources in performing research related to carbon dioxide emissions. Manual underground carbon dioxide storage and carbon dioxide-enhanced oil recovery are schemes with great potential and prospect for reducing carbon dioxide emissions. Compared with other schemes for reducing carbon dioxide emissions, aforementioned two schemes exhibit high storage capacity and yield considerable economic benefits, so they have become research focuses for reducing carbon dioxide emissions. This paper introduces the research progress in underground carbon dioxide storage and enhanced oil recovery, pointing out the significance and necessity of carbon dioxide-driven enhanced oil recovery.
30 CFR 715.19 - Use of explosives.
Code of Federal Regulations, 2010 CFR
2010-07-01
... wells, petroleum or gas-storage facilities, municipal water-storage facilities, fluid-transmission pipelines, gas or oil-collection lines, or water and sewage lines; and (C) 500 feet of an underground mine... explosive materials shall— (i) Have demonstrated a knowledge of, and a willingness to comply with, safety...
40 CFR 282.96 - Virginia State-Administered Program.
Code of Federal Regulations, 2010 CFR
2010-07-01
...” includes heating oil tanks of greater than 5,000 gallon capacity and “Regulated substance” 9 VAC 25-580-130General requirements for all petroleum and hazardous substance UST systems, heating oil tanks of greater... WASTES (CONTINUED) APPROVED UNDERGROUND STORAGE TANK PROGRAMS Approved State Programs § 282.96 Virginia...
NASA Technical Reports Server (NTRS)
Bengelsdorf, Irv
1991-01-01
The Goldstone Deep Space Communications Complex (GDSCC), located in the Mojave Desert about 40 miles north of Barstow, California, and about 160 miles northeast of Pasadena, is part of the National Aeronautics and Space Administration's (NASA's) Deep Space Network, one of the world's largest and most sensitive scientific telecommunications and radio navigation networks. Activities at the GDSCC are carried out in support of six large parabolic dish antennas. As a large-scale facility located in a remote, isolated desert region, the GDSCC operations require numerous on-site storage facilities for gasoline, diesel oil, hydraulic oil, and waste oil. These fluids are stored in underground storage tanks (USTs). This present volume describes what happened to the 26 USTs that remained at the GDSCC. Twenty-four of these USTs were constructed of carbon steel without any coating for corrosion protection, and without secondary containment or leak detection. Two remaining USTs were constructed of fiberglass-coated carbon steel but without secondary containment or leak protection. Of the 26 USTs that remained at the GDSCC, 23 were cleaned, removed from the ground, cut up, and hauled away from the GDSCC for environmentally acceptable disposal. Three USTs were permanently closed (abandoned in place).
NASA Astrophysics Data System (ADS)
Li, Yipeng; Liu, Quanzhen; Meng, He; Sun, Lifu; Zhang, Yunpeng
2013-03-01
At present Fiber Reinforced Plastics (FRP) double wall underground storage gasoline tanks are wildly used. An FRP product with a resistance of more than 1011 Ω is a static non-conductor, so it is difficult for the static electricity in the FRP product to decay into the earth. In this paper an experimental system was built to simulate an automobile gasoline filling station. Some electrostatic parameters of the gasoline, including volume charge density, were tested when gasoline was unloaded into a FRP double wall underground storage tank. Measurements were taken to make sure the volume charge density in the oil-outlet was similar to the volume charge density in the tank. In most cases the volume charge density of the gasoline was more than 22.7 μC m-3, which is likely to cause electrostatic discharge in FRP double wall underground storage gasoline tanks. On the other hand, it would be hard to ignite the vapor by electrostatic discharge since the vapor pressure in the tanks is over the explosion limit. But when the tank is repaired or re-used, the operators must pay attention to the static electricity and some measurements should be taken to avoid electrostatic accident. Besides the relaxation time of charge in the FRP double wall gasoline storage tanks should be longer.
ORD RESEARCH PRIORITIES IN BIOREMEDIATION
ORD is conducting research on bioremediation impacting Superfund sites, RCRA facilities, underground storage tanks and oil spills. Work supporting Superfund is focused on understanding monitored natural recovery in sediments for contaminants including PCBs and PAHs. Under RCRA,...
75 FR 28820 - Notice of Lodging of Consent Decree Under the Resource Conservation and Recovery Act
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-24
... tanks owned or operated by the defendants at Tanana Oil Station 409, formerly located at 7526 North.... Tanana Oil Corp., et al., Civil Action No. 05-2540, was lodged with the United States District Court for... violating regulations regarding underground storage tanks and for failing to comply with an administrative...
DOE Office of Scientific and Technical Information (OSTI.GOV)
DeRouen, L.R.; Hann, R.W.; Casserly, D.M.
1983-02-01
The Department of Energy's Strategic Petroleum Reserve Program began discharging brine into the Gulf of Mexico from its West Hackberry site near Cameron, Louisiana in May 1981. The brine originates from underground salt domes being leached with water from the Intracoastal Waterway, making available vast underground storage caverns for crude oil. The effects of brine discharge on aquatic organisms are presented in this volume. The topics covered are: benthos; nekton; phytoplankton; zooplankton; and data management.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1995-12-01
The Strategic Petroleum Reserve (SPR) Weeks Island site is one of five underground salt dome crude oils storage facilities operated by the Department of Energy (DOE). It is located in Iberia Parish, Louisiana. The purpose of the proposed action is to decommission the Weeks Island crude oil storage after the oil inventory has been transferred to other SPR facilities. Water intrusion into the salt dome storage chambers and the development of two sinkholes located near the aboveground facilities has created uncertain geophysical conditions. This Environmental Assessment describes the proposed decommissioning operation, its alternatives, and potential environmental impacts. Based on thismore » analyses, DOE has determined that the proposed action is not a major Federal action significantly affecting the quality of the human environment within the meaning of the National Environmental Policy Act (NEPA) and has issued the Finding of No Significant Impact (FONSI).« less
NASA Astrophysics Data System (ADS)
Moon, Jiwon; Yeo, In Wook
2013-04-01
Underground unlined caverns have been constructed in fractured rocks to stockpile oil and petroleum products, where they are hydraulically contained by natural groundwater pressure. However, for the case that natural groundwater pressure is not maintained at the required level, water curtain boreholes, through which water is injected, are often constructed above the cavern as engineering barrier to secure water pressure enough to overwhelm the operational pressure of the cavern. For secure containment of oil and petroleum products inside the cavern, it is essential to keep water pressure around the cavern higher than operational pressure of the cavern using either natural groundwater pressure or engineering barrier. In the Republic of Korea, a number of underground stockpile bases are being operated by Korea National Oil Corporation (KNOC) and private companies, most of which have water curtain system. The criterion that KNOC adopts for water curtain system design and operation such as the vertical distance from the cavern and operational injection rate is based on the Åberg hypothesis that the vertical hydraulic gradient should be larger than one. The criterion has been used for maintaining oil storage cavern without its thorough review. In this study, systematic numerical works have been done for reviewing the Åberg criterion. As groundwater predominantly takes places through fractures in underground caverns, discrete fracture modeling approach is essential for this study. Fracture data, obtained from boreholes drilled at the stage of site investigation at the Yeosu stockpile base in Korea, were statistically analyzed in terms of orientation and intensity, which were used to generate the site descriptive three dimensional fracture networks. Then, groundwater flow modeling has been carried out for the fracture networks. Constant head boundaries were applied along the circumference of the cavern and water curtain boreholes. Main flow channel and hydraulic connectivity between water curtain boreholes and the caverns have been identified, along which hydraulic heads are monitored to find out whether the required hydraulic pressure is maintained around the cavern. The flow modeling has been repeatedly carried out at different constant head boundary conditions to create the criterion for the optimal operation of water curtain system.
Gniese, Claudia; Bombach, Petra; Rakoczy, Jana; Hoth, Nils; Schlömann, Michael; Richnow, Hans-Hermann; Krüger, Martin
2014-01-01
This chapter gives the reader an introduction into the microbiology of deep geological systems with a special focus on potential geobiotechnological applications and respective risk assessments. It has been known for decades that microbial activity is responsible for the degradation or conversion of hydrocarbons in oil, gas, and coal reservoirs. These processes occur in the absence of oxygen, a typical characteristic of such deep ecosystems. The understanding of the responsible microbial processes and their environmental regulation is not only of great scientific interest. It also has substantial economic and social relevance, inasmuch as these processes directly or indirectly affect the quantity and quality of the stored oil or gas. As outlined in the following chapter, in addition to the conventional hydrocarbons, new interest in such deep subsurface systems is rising for different technological developments. These are introduced together with related geomicrobiological topics. The capture and long-termed storage of large amounts of carbon dioxide, carbon capture and storage (CCS), for example, in depleted oil and gas reservoirs, is considered to be an important options to mitigate greenhouse gas emissions and global warming. On the other hand, the increasing contribution of energy from natural and renewable sources, such as wind, solar, geothermal energy, or biogas production leads to an increasing interest in underground storage of renewable energies. Energy carriers, that is, biogas, methane, or hydrogen, are often produced in a nonconstant manner and renewable energy may be produced at some distance from the place where it is needed. Therefore, storing the energy after its conversion to methane or hydrogen in porous reservoirs or salt caverns is extensively discussed. All these developments create new research fields and challenges for microbiologists and geobiotechnologists. As a basis for respective future work, we introduce the three major topics, that is, CCS, underground storage of gases from renewable energy production, and the production of geothermal energy, and summarize the current stat of knowledge about related geomicrobiological and geobiotechnological aspects in this chapter. Finally, recommendations are made for future research.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 26 2010-07-01 2010-07-01 false Ownership of an underground storage tank or underground storage tank system or facility or property on which an underground storage tank or underground storage tank system is located. 280.220 Section 280.220 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID...
Preparing near-surface heavy oil for extraction using microbial degradation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Busche, Frederick D.; Rollins, John B.; Noyes, Harold J.
In one embodiment, the invention provides a system including at least one computing device for enhancing the recovery of heavy oil in an underground, near-surface crude oil extraction environment by performing a method comprising sampling and identifying microbial species (bacteria and/or fungi) that reside in the underground, near-surface crude oil extraction environment; collecting rock and fluid property data from the underground, near-surface crude oil extraction environment; collecting nutrient data from the underground, near-surface crude oil extraction environment; identifying a preferred microbial species from the underground, near-surface crude oil extraction environment that can transform the heavy oil into a lighter oil;more » identifying a nutrient from the underground, near-surface crude oil extraction environment that promotes a proliferation of the preferred microbial species; and introducing the nutrient into the underground, near-surface crude oil extraction environment.« less
Sumioka, S.S.
1995-01-01
The removal of an underground waste-oil storage tank in Mount Rainier National Park, at Longmire, Washington, led to the discovery that soil surrounding the tank was saturated with unidentified petroleum hydrocarbons. Subsequent investigations by the National Park Service indicated that a petroleum product smelling like diesel oil was present in the unsaturated zone as far as 120 feet from the tank site. A study was conducted by the U.S. Geological Survey in cooperation with the National Park Service to determine the extent to which the petroleum hydrocarbons have affected the unsaturated zone and ground water in the Longmire area. Measurements of water levels in wells and of water-surface elevations of the Nisqually River and a wetland west of Longmire indicate that ground water does not flow from the maintenance area to the river or to the wetland. Waste oil and diesel oil were detected in soil samples from the site closest to the waste-oil storage-tank site. Diesel oil was also detected in samples from a site about 200 feet northwest of the storage-tank site. Organic compounds of undetermined origin were detected in soil samples from all of the other sites. Waste oil was not conclusively detected in any of the ground-water samples. Diesel oil was detected in water samples from the well closest to the storage tank and from a well about 200 feet west of the storage-tank site. Ground-water samples from all of the other wells contained organic compounds of undetermined origin.
Final report on Weeks Island Monitoring Phase : 1999 through 2004.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ehgartner, Brian L.; Munson, Darrell Eugene
2005-05-01
This Final Report on the Monitoring Phase of the former Weeks Island Strategic Petroleum Reserve crude oil storage facility details the results of five years of monitoring of various surface accessible quantities at the decommissioned facility. The Weeks Island mine was authorized by the State of Louisiana as a Strategic Petroleum Reserve oil storage facility from 1979 until decommissioning of the facility in 1999. Discovery of a sinkhole over the facility in 1992 with freshwater inflow to the facility threatened the integrity of the oil storage and led to the decision to remove the oil, fill the chambers with brine,more » and decommission the facility. Thereafter, a monitoring phase, by agreement between the Department of Energy and the State, addressed facility stability and environmental concerns. Monitoring of the surface ground water and the brine of the underground chambers from the East Fill Hole produced no evidence of hydrocarbon contamination, which suggests that any unrecovered oil remaining in the underground chambers has been contained. Ever diminishing progression of the initial major sinkhole, and a subsequent minor sinkhole, with time was verification of the response of sinkholes to filling of the facility with brine. Brine filling of the facility ostensively eliminates any further growth or new formation from freshwater inflow. Continued monitoring of sinkhole response, together with continued surface surveillance for environmental problems, confirmed the intended results of brine pressurization. Surface subsidence measurements over the mine continued throughout the monitoring phase. And finally, the outward flow of brine was monitored as a measure of the creep closure of the mine chambers. Results of each of these monitoring activities are presented, with their correlation toward assuring the stability and environmental security of the decommissioned facility. The results suggest that the decommissioning was successful and no contamination of the surface environment by crude oil has been found.« less
Economic evaluation on CO₂-EOR of onshore oil fields in China
Wei, Ning; Li, Xiaochun; Dahowski, Robert T.; ...
2015-06-01
Carbon dioxide enhanced oil recovery (CO₂-EOR) and sequestration in depleted oil reservoirs is a plausible option for utilizing anthropogenic CO₂ to increase oil production while storing CO₂ underground. Evaluation of the storage resources and cost of potential CO₂-EOR projects is an essential step before the commencement of large-scale deployment of such activities. In this paper, a hybrid techno-economic evaluation method, including a performance model and cost model for onshore CO₂-EOR projects, has been developed based on previous studies. Total 296 onshore oil fields, accounting for about 70% of total mature onshore oil fields in China, were evaluated by the techno-economicmore » method. The key findings of this study are summarized as follows: (1) deterministic analysis shows there are approximately 1.1 billion tons (7.7 billion barrels) of incremental crude oil and 2.2 billion tons CO₂ storage resource for onshore CO₂-EOR at net positive revenue within the Chinese oil fields reviewed under the given operating strategy and economic assumptions. (2) Sensitivity study highlights that the cumulative oil production and cumulative CO₂ storage resource are very sensitive to crude oil price, CO₂ cost, project lifetime, discount rate and tax policy. High oil price, short project lifetime, low discount rate, low CO₂ cost, and low tax policy can greatly increase the net income of the oil enterprise, incremental oil recovery and CO₂ storage resource. (3) From this techno-economic evaluation, the major barriers to large-scale deployment of CO₂-EOR include complex geological conditions, low API of crude oil, high tax policy, and lack of incentives for the CO₂-EOR project.« less
Economic evaluation on CO₂-EOR of onshore oil fields in China
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wei, Ning; Li, Xiaochun; Dahowski, Robert T.
Carbon dioxide enhanced oil recovery (CO₂-EOR) and sequestration in depleted oil reservoirs is a plausible option for utilizing anthropogenic CO₂ to increase oil production while storing CO₂ underground. Evaluation of the storage resources and cost of potential CO₂-EOR projects is an essential step before the commencement of large-scale deployment of such activities. In this paper, a hybrid techno-economic evaluation method, including a performance model and cost model for onshore CO₂-EOR projects, has been developed based on previous studies. Total 296 onshore oil fields, accounting for about 70% of total mature onshore oil fields in China, were evaluated by the techno-economicmore » method. The key findings of this study are summarized as follows: (1) deterministic analysis shows there are approximately 1.1 billion tons (7.7 billion barrels) of incremental crude oil and 2.2 billion tons CO₂ storage resource for onshore CO₂-EOR at net positive revenue within the Chinese oil fields reviewed under the given operating strategy and economic assumptions. (2) Sensitivity study highlights that the cumulative oil production and cumulative CO₂ storage resource are very sensitive to crude oil price, CO₂ cost, project lifetime, discount rate and tax policy. High oil price, short project lifetime, low discount rate, low CO₂ cost, and low tax policy can greatly increase the net income of the oil enterprise, incremental oil recovery and CO₂ storage resource. (3) From this techno-economic evaluation, the major barriers to large-scale deployment of CO₂-EOR include complex geological conditions, low API of crude oil, high tax policy, and lack of incentives for the CO₂-EOR project.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pickles, W. L.; Ebrom, D. A.
This collaborative effort was in support of the CO 2 Capture Project (CCP), to develop techniques that integrate overhead images of plant species, plant health, geological formations, soil types, aquatic, and human use spatial patterns for detection and discrimination of any CO 2 releases from underground storage formations. The goal of this work was to demonstrate advanced hyperspectral geobotanical remote sensing methods to assess potential leakage of CO 2 from underground storage. The timeframes and scales relevant to the long-term storage of CO 2 in the subsurface make remote sensing methods attractive. Moreover, it has been shown that individual fieldmore » measurements of gas composition are subject to variability on extremely small temporal and spatial scales. The ability to verify ultimate reservoir integrity and to place individual surface measurements into context will be crucial to successful long-term monitoring and verification activities. The desired results were to produce a defined and tested procedure that could be easily used for long-term monitoring of possible CO 2 leakage from underground CO 2 sequestration sites. This testing standard will be utilized on behalf of the oil industry.« less
1998-02-01
decision document presents the U.S. Army’s (Army’s) selected remedial actions for AOCs 32 DRMO Yard, including Underground Storage Tank (UST) #13...of commencing the remedial action to ensure that the remedy at each AOC continues to provide adequate protection of human health and the environment... Devens , Massachusetts RAO remedial action objective RBC risk-based concentration RCRA Resource Conservation and Recovery Act RI remedial
CLOSURE REPORT FOR CORRECTIVE ACTION UNIT 204: STORAGE BUNKERS, NEVADA TEST SITE, NEVADA
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
Corrective Action Unit (CAU) 330 consists of four Corrective Action Sites (CASs) located in Areas 6, 22, and 23 of the Nevada Test Site (NTS). The unit is listed in the Federal Facility Agreement and Consent Order (FFACO, 1996) as CAU 330: Areas 6, 22, and 23 Tanks and Spill Sites. CAU 330 consists of the following CASs: CAS 06-02-04, Underground Storage Tank (UST) and Piping CAS 22-99-06, Fuel Spill CAS 23-01-02, Large Aboveground Storage Tank (AST) Farm CAS 23-25-05, Asphalt Oil Spill/Tar Release
INDOOR AIR SAMPLING, SUB-SLAB VAPOR SAMPLING, AND SLAB AIR-PERMEABILITY TESTING AT THE RAYMARK SITE
By 2005, U.S. EPA and its state, tribal and local partners must assess, reduce, and/or control the risk to human health and the environment at more than 374,000 contaminated Superfund, RCRA, underground storage tank (UST), brownfield and oil sites. U.S. EPA is currently developi...
INDOOR AIR SAMPLING, SUB-SLAB VAPOR SAMPLING, AND SLAB AIR PERMEABILITY TESTING AT THE RAYMARK SITE
By 2005, U.S. EPA and its state, tribal and local partners must assess, reduce, and/or control the risk to human health and the environment at more than 374,000 contaminated Superfund, RCRA, underground storage tank (UST), brownfield and oil sites. U.S. EPA is currently developi...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stein, Joshua S.; Rautman, Christopher Arthur
The Bryan Mound salt dome, located near Freeport, Texas, is home to one of four underground crude oil-storage facilities managed by the U. S. Department of Energy Strategic Petroleum Reserve (SPR) Program. Sandia National Laboratories, as the geotechnical advisor to the SPR, conducts site-characterization investigations and other longer-term geotechnical and engineering studies in support of the program. This report describes the conversion of two-dimensional geologic interpretations of the Bryan Mound site into three-dimensional geologic models. The new models include the geometry of the salt dome, the surrounding sedimentary units, mapped faults, and the 20 oil-storage caverns at the site. Thismore » work provides an internally consistent geologic model of the Bryan Mound site that can be used in support of future work.« less
Solid fossil-fuel recovery by electrical induction heating in situ - A proposal
NASA Astrophysics Data System (ADS)
Fisher, S.
1980-04-01
A technique, termed electrical induction heating, is proposed for in situ processes of energy production from solid fossil fuels, such as bitumen production from underground distillation of oil sand; oil by underground distillation of oil shale; petroleum from heavy oil by underground mobilization of heavy oil, from either residues of conventional liquid petroleum deposits or new deposits of viscous oil; methane and coal tar from lignite and coal deposits by underground distillation of coal; and generation of electricity by surface combustion of low calorific-value gas from underground coke gasification by combustion of the organic residue left from the underground distillation of coal by induction heating. A method of surface distillation of mined coking coal by induction heating to produce coke, methane, and coal tar is also proposed.
18 CFR 157.213 - Underground storage field facilities.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 18 Conservation of Power and Water Resources 1 2013-04-01 2013-04-01 false Underground storage... of the Natural Gas Act for Certain Transactions and Abandonment § 157.213 Underground storage field... operate facilities for the remediation and maintenance of an existing underground storage facility...
18 CFR 157.213 - Underground storage field facilities.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 18 Conservation of Power and Water Resources 1 2014-04-01 2014-04-01 false Underground storage... of the Natural Gas Act for Certain Transactions and Abandonment § 157.213 Underground storage field... operate facilities for the remediation and maintenance of an existing underground storage facility...
40 CFR 280.230 - Operating an underground storage tank or underground storage tank system.
Code of Federal Regulations, 2010 CFR
2010-07-01
... underground storage tank or underground storage tank system. (a) Operating an UST or UST system prior to...) Operating an UST or UST system after foreclosure. The following provisions apply to a holder who, through..., the purchaser must decide whether to operate or close the UST or UST system in accordance with...
40 CFR 280.230 - Operating an underground storage tank or underground storage tank system.
Code of Federal Regulations, 2011 CFR
2011-07-01
... underground storage tank or underground storage tank system. (a) Operating an UST or UST system prior to...) Operating an UST or UST system after foreclosure. The following provisions apply to a holder who, through..., the purchaser must decide whether to operate or close the UST or UST system in accordance with...
40 CFR 280.230 - Operating an underground storage tank or underground storage tank system.
Code of Federal Regulations, 2014 CFR
2014-07-01
... underground storage tank or underground storage tank system. (a) Operating an UST or UST system prior to...) Operating an UST or UST system after foreclosure. The following provisions apply to a holder who, through..., the purchaser must decide whether to operate or close the UST or UST system in accordance with...
40 CFR 280.230 - Operating an underground storage tank or underground storage tank system.
Code of Federal Regulations, 2012 CFR
2012-07-01
... underground storage tank or underground storage tank system. (a) Operating an UST or UST system prior to...) Operating an UST or UST system after foreclosure. The following provisions apply to a holder who, through..., the purchaser must decide whether to operate or close the UST or UST system in accordance with...
40 CFR 280.230 - Operating an underground storage tank or underground storage tank system.
Code of Federal Regulations, 2013 CFR
2013-07-01
... underground storage tank or underground storage tank system. (a) Operating an UST or UST system prior to...) Operating an UST or UST system after foreclosure. The following provisions apply to a holder who, through..., the purchaser must decide whether to operate or close the UST or UST system in accordance with...
Environmental projects. Volume 2: Underground storage tanks compliance program
NASA Technical Reports Server (NTRS)
Kushner, L.
1987-01-01
Six large parabolic dish antennas are located at the Goldstone Deep Space Communications Complex north of Barstow, California. As a large-scale facility located in a remote, isolated desert region, the GDSCC operations require numerous on-site storage facilities for gasoline, diesel and hydraulic oil. These essential fluids are stored in underground storage tanks (USTs). Because USTs may develop leaks with the resultant seepage of their hazardous contents into the surrounding soil, local, State and Federal authorities have adopted stringent regulations for the testing and maintenance of USTs. Under the supervision of JPL's Office of Telecommunications and Data Acquisition, a year-long program has brought 27 USTs at the Goldstone Complex into compliance with Federal, State of California and County of San Bernadino regulations. Of these 27 USTs, 15 are operating today, 11 have been temporary closed down, and 1 abandoned in place. In 1989, the 15 USTs now operating at the Goldstone DSCC will be replaced either by modern, double-walled USTs equipped with automatic sensors for leak detection, or by above ground storage tanks. The 11 inactivated USTs are to be excavated, removed and disposed of according to regulation.
30 CFR 57.4460 - Storage of flammable liquids underground.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Storage of flammable liquids underground. 57... Fire Prevention and Control Flammable and Combustible Liquids and Gases § 57.4460 Storage of flammable liquids underground. (a) Flammable liquids shall not be stored underground, except— (1) Small quantities...
30 CFR 57.4460 - Storage of flammable liquids underground.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Storage of flammable liquids underground. 57... Fire Prevention and Control Flammable and Combustible Liquids and Gases § 57.4460 Storage of flammable liquids underground. (a) Flammable liquids shall not be stored underground, except— (1) Small quantities...
30 CFR 57.4460 - Storage of flammable liquids underground.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Storage of flammable liquids underground. 57... Fire Prevention and Control Flammable and Combustible Liquids and Gases § 57.4460 Storage of flammable liquids underground. (a) Flammable liquids shall not be stored underground, except— (1) Small quantities...
30 CFR 57.4460 - Storage of flammable liquids underground.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Storage of flammable liquids underground. 57... Fire Prevention and Control Flammable and Combustible Liquids and Gases § 57.4460 Storage of flammable liquids underground. (a) Flammable liquids shall not be stored underground, except— (1) Small quantities...
Leaking Underground Storage Tank (LUST) Trust Fund
In 1986, Congress created the Leaking Underground Storage Tank (LUST) Trust Fund to address releases from federally regulated underground storage tanks (USTs) by amending Subtitle I of the Solid Waste Disposal Act.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-09
... extract oil from shale in underground metal and nonmetal I-A and I-B mines (those that operate in a... underground oil shale mines. The standard requires that, prior to ignition of underground retorts, mine...
Energy Policy Act of 2005 and Underground Storage Tanks (USTs)
The Energy Policy Act of 2005 significantly affected federal and state underground storage tank programs, required major changes to the programs, and is aimed at reducing underground storage tank releases to our environment.
NASA Technical Reports Server (NTRS)
Hausz, W.; Berkowitz, B. J.; Hare, R. C.
1978-01-01
Over forty thermal energy storage (TES) concepts gathered from the literature and personal contacts were studied for their suitability for the electric utility application of storing energy off-peak discharge during peak hours. Twelve selections were derived from the concepts for screening; they used as storage media high temperature water (HTW), hot oil, molten salts, and packed beds of solids such as rock. HTW required pressure containment by prestressed cast-iron or concrete vessels, or lined underground cavities. Both steam generation from storage and feedwater heating from storage were studied. Four choices were made for further study during the project. Economic comparison by electric utility standard cost practices, and near-term availability (low technical risk) were principal criteria but suitability for utility use, conservation potential, and environmental hazards were considered.
9. PHOTOCOPY, ARCHITECTURAL SECTIONS AND DETAIL DRAWING OF UNDERGROUND STORAGE ...
9. PHOTOCOPY, ARCHITECTURAL SECTIONS AND DETAIL DRAWING OF UNDERGROUND STORAGE MAGAZINES AND LAUNCHER-LOADER ASSEMBLIES. - NIKE Missile Base SL-40, Underground Storage Magazines & Launcher-Loader Assemblies, Southwesternmost end of launch area, Hecker, Monroe County, IL
Project #OPE-FY16-0013, March 8, 2016. The EPA OIG plans to begin preliminary research on the EPA’s work related to Underground Storage Tank and Leaking Underground Storage Tank programs in Indian country.
40 CFR 282.73 - Minnesota State-Administered Program.
Code of Federal Regulations, 2014 CFR
2014-07-01
... WASTES (CONTINUED) APPROVED UNDERGROUND STORAGE TANK PROGRAMS Approved State Programs § 282.73 Minnesota State-Administered Program. (a) The State of Minnesota's underground storage tank program is approved in... chapter. EPA approved the Minnesota underground storage tank program on November 30, 2001, and approval...
40 CFR 282.73 - Minnesota State-Administered Program.
Code of Federal Regulations, 2011 CFR
2011-07-01
... WASTES (CONTINUED) APPROVED UNDERGROUND STORAGE TANK PROGRAMS Approved State Programs § 282.73 Minnesota State-Administered Program. (a) The State of Minnesota's underground storage tank program is approved in... chapter. EPA approved the Minnesota underground storage tank program on November 30, 2001, and approval...
40 CFR 282.73 - Minnesota State-Administered Program.
Code of Federal Regulations, 2013 CFR
2013-07-01
... WASTES (CONTINUED) APPROVED UNDERGROUND STORAGE TANK PROGRAMS Approved State Programs § 282.73 Minnesota State-Administered Program. (a) The State of Minnesota's underground storage tank program is approved in... chapter. EPA approved the Minnesota underground storage tank program on November 30, 2001, and approval...
40 CFR 282.73 - Minnesota State-Administered Program.
Code of Federal Regulations, 2012 CFR
2012-07-01
... WASTES (CONTINUED) APPROVED UNDERGROUND STORAGE TANK PROGRAMS Approved State Programs § 282.73 Minnesota State-Administered Program. (a) The State of Minnesota's underground storage tank program is approved in... chapter. EPA approved the Minnesota underground storage tank program on November 30, 2001, and approval...
76 FR 46798 - Compatibility of Underground Storage Tank Systems With Biofuel Blends; Correction
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-03
... ENVIRONMENTAL PROTECTION AGENCY [EPA-HQ-UST-2010-0651; FRL-9447-3] Compatibility of Underground Storage Tank Systems With Biofuel Blends; Correction AGENCY: Environmental Protection Agency (EPA). ACTION... of underground storage tanks (USTs) can demonstrate compliance with the Federal compatibility...
STATE-OF-THE-ART PROCEDURES AND EQUIPMENT FOR INTERNAL INSPECTION OF UNDERGROUND STORAGE TANKS
Preventing leaks from underground storage tanks is of paramount importance in this decade as environmental resources are seriously threatened by the release of toxic substances and costs of reparation are exorbitant. Inspecting underground storage tanks is one action that helps p...
7 CFR 1955.57 - Real property containing underground storage tanks.
Code of Federal Regulations, 2010 CFR
2010-01-01
...; (3) Septic tanks; (4) Pipeline facilities (including gathering lines) regulated under; (i) The... 7 Agriculture 14 2010-01-01 2009-01-01 true Real property containing underground storage tanks... Property § 1955.57 Real property containing underground storage tanks. Within 30 days of acquisition of...
Oil and gas field code master list 1994
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
This is the thirteenth annual edition of the Energy Information Administration`s (EIA) Oil and Gas Field Code Master List. It reflects data collected through October 1994 and provides standardized field name spellings and codes for all identified oil and/or gas fields in the United States. The master field name spellings and codes are to be used by respondents when filing the following Department of Energy (DOE) forms: Form EIA-23, {open_quotes}Annual Survey of Domestic Oil and Gas Reserves,{close_quotes} filed by oil and gas well operators (field codes are required from larger operators only); Forms FERC 8 and EIA-191, {open_quotes}Underground Gas Storagemore » Report,{close_quotes} filed by natural gas producers and distributors who operate underground natural gas storage facilities. Other Federal and State government agencies, as well as industry, use the EIA Oil and Gas Field Code Master List as the standard for field identification. A machine-readable version of the Oil and Gas Field Code Master List is available from the National Technical Information Service, 5285 Port Royal Road, Springfield, Virginia 22161, (703) 487-4650. In order for the Master List to be useful, it must be accurate and remain current. To accomplish this, EIA constantly reviews and revises this list. The EIA welcomes all comments, corrections, and additions to the Master List. All such information should be given to the EIA Field Code Coordinator at (214) 953-1858. EIA gratefully acknowledges the assistance provides by numerous State organizations and trade associations in verifying the existence of fields and their official nomenclature.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-03
... Activities; Submission to OMB for Review and Approval; Comment Request; Underground Storage Tanks: [email protected] , or by mail to: EPA Docket Center, Environmental Protection Agency, Underground Storage Tank... White, Office of Underground Storage Tanks, Mail Code 5403P, Environmental Protection Agency, 1200...
Two different sensor technologies and their properties were analyzed. he nalysis simulated a leak which occurs from an underground storage tank. igaro gas sensors and the Adsistor gas sensor were tested in simulated underground storage tank nvironments using the Carnegie Mellon R...
The total number of confirmed releases from underground storage tanks is increasing rapidly. In addition, the treatment of contaminants in soil and groundwater at leaking underground storage tank (LUST) sites presents complex technical challenges. Most of the remedial technologie...
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Underground transformer stations, combustible... and Control Firefighting Equipment § 57.4262 Underground transformer stations, combustible liquid storage and dispensing areas, pump rooms, compressor rooms, and hoist rooms. Transformer stations, storage...
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Underground transformer stations, combustible... and Control Firefighting Equipment § 57.4262 Underground transformer stations, combustible liquid storage and dispensing areas, pump rooms, compressor rooms, and hoist rooms. Transformer stations, storage...
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Underground transformer stations, combustible... and Control Firefighting Equipment § 57.4262 Underground transformer stations, combustible liquid storage and dispensing areas, pump rooms, compressor rooms, and hoist rooms. Transformer stations, storage...
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Underground transformer stations, combustible... and Control Firefighting Equipment § 57.4262 Underground transformer stations, combustible liquid storage and dispensing areas, pump rooms, compressor rooms, and hoist rooms. Transformer stations, storage...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Underground transformer stations, combustible... and Control Firefighting Equipment § 57.4262 Underground transformer stations, combustible liquid storage and dispensing areas, pump rooms, compressor rooms, and hoist rooms. Transformer stations, storage...
2011-09-01
SEP 2011 2. REPORT TYPE N/A 3. DATES COVERED - 4. TITLE AND SUBTITLE Final Phase I Environmental Baseline Survey Parcel E2, F, and I...lead-based paint LUST leaking underground storage tank M.D.M. Mount Diablo Meridian MFH military family housing MHPI Military Housing...northwest OWS oil/water separator PADS PCB Activity Database PCB polychorinated biphenyl PCR Physical Condition Report PDF portable
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-15
... ENVIRONMENTAL PROTECTION AGENCY 40 CFR Part 281 [EPA-R10-UST-2011-0097; FRL-9296-1] Oregon: Tentative Approval of State Underground Storage Tank Program: Public Hearing Cancellation AGENCY... application for final approval of its Underground Storage Tank (UST) Program under Subtitle I of the Resource...
Over 315,000 releases from leaking underground storage tanks (USTs) were reported by state and local environmental agencies as of March 19961. EPA's Office of Underground Storage Tanks (OUST) anticipates that at least 100,000 additional releases will be confirmed in the next few ...
30 CFR 75.1902 - Underground diesel fuel storage-general requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Underground diesel fuel storage-general... LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Diesel-Powered Equipment § 75.1902 Underground diesel fuel storage—general requirements. (a) All diesel fuel must be stored...
30 CFR 75.1902 - Underground diesel fuel storage-general requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Underground diesel fuel storage-general... LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Diesel-Powered Equipment § 75.1902 Underground diesel fuel storage—general requirements. (a) All diesel fuel must be stored...
U.S. Naval Base, Pearl Harbor, Red Hill Underground Fuel Storage ...
U.S. Naval Base, Pearl Harbor, Red Hill Underground Fuel Storage System, Linear underground system extending from North Road to Icarus Way, Joint Base Pearl Harbor-Hickam, Honolulu, Honolulu County, HI
Βedrock instability of underground storage systems in the Czech Republic, Central Europe
NASA Astrophysics Data System (ADS)
Novakova, Lucie; Broz, Milan; Zaruba, Jiri; Sosna, Karel; Najser, Jan; Rukavickova, Lenka; Franek, Jan; Rudajev, Vladimir
2016-06-01
Underground storage systems are currently being used worldwide for the geological storage of natural gas (CH4), the geological disposal of CO2, in geothermal energy, or radioactive waste disposal. We introduce a complex approach to the risks posed by induced bedrock instabilities in deep geological underground storage sites. Bedrock instability owing to underground openings has been studied and discussed for many years. The Bohemian Massif in the Czech Republic (Central Europe) is geologically and tectonically complex. However, this setting is ideal for learning about the instability state of rock masses. Longterm geological and mining studies, natural and induced seismicity, radon emanations, and granite properties as potential storage sites for disposal of radioactive waste in the Czech Republic have provided useful information. In addition, the Czech Republic, with an average concentration radon of 140 Bq m-3, has the highest average radon concentrations in the world. Bedrock instabilities might emerge from microscale features, such as grain size and mineral orientation, and microfracturing. Any underground storage facility construction has to consider the stored substance and the geological settings. In the Czech Republic, granites and granitoids are the best underground storage sites. Microcrack networks and migration properties are rock specific and vary considerably. Moreover, the matrix porosity also affects the mechanical properties of the rocks. Any underground storage site has to be selected carefully. The authors suggest to study the complex set of parameters from micro to macroscale for a particular place and type of rock to ensure that the storage remains safe and stable during construction, operation, and after closure.
7. PHOTOCOPY, PLUMBING AND MECHANICAL PLAN AND DETAILS FOR UNDERGROUND ...
7. PHOTOCOPY, PLUMBING AND MECHANICAL PLAN AND DETAILS FOR UNDERGROUND STORAGE MAGAZINES AND LAUNCHER-LOADER ASSEMBLIES. - NIKE Missile Base SL-40, Underground Storage Magazines & Launcher-Loader Assemblies, Southwesternmost end of launch area, Hecker, Monroe County, IL
8. PHOTOCOPY, ARCHITECTURAL FLOOR PLAN AND DETAIL DRAWING OF UNDERGROUND ...
8. PHOTOCOPY, ARCHITECTURAL FLOOR PLAN AND DETAIL DRAWING OF UNDERGROUND STORAGE MAGAZINES AND LAUNCHER-LOADER ASSEMBLIES. - NIKE Missile Base SL-40, Underground Storage Magazines & Launcher-Loader Assemblies, Southwesternmost end of launch area, Hecker, Monroe County, IL
Permanent Closure of MFC Biodiesel Underground Storage Tank 99ANL00013
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kerry L. Nisson
2012-10-01
This closure package documents the site assessment and permanent closure of the Materials and Fuels Complex biodiesel underground storage tank 99ANL00013 in accordance with the regulatory requirements established in 40 CFR 280.71, “Technical Standards and Corrective Action Requirements for Owners and Operators of Underground Storage Tanks: Out-of-Service UST Systems and Closure.”
Kodama, Yumiko; Watanabe, Kazuya
2003-01-01
Molecular approaches have shown that a group of bacteria (called cluster 1 bacteria) affiliated with the epsilon subclass of the class Proteobacteria constituted major populations in underground crude-oil storage cavities. In order to unveil their physiology and ecological niche, this study isolated bacterial strains (exemplified by strain YK-1) affiliated with the cluster 1 bacteria from an oil storage cavity at Kuji in Iwate, Japan. 16S rRNA gene sequence analysis indicated that its closest relative was Thiomicrospira denitrificans (90% identity). Growth experiments under anaerobic conditions showed that strain YK-1 was a sulfur-oxidizing obligate chemolithotroph utilizing sulfide, elemental sulfur, thiosulfate, and hydrogen as electron donors and nitrate as an electron acceptor. Oxygen also supported its growth only under microaerobic conditions. Strain YK-1 could not grow on nitrite, and nitrite was the final product of nitrate reduction. Neither sugars, organic acids (including acetate), nor hydrocarbons could serve as carbon and energy sources. A typical stoichiometry of its energy metabolism followed an equation: S(2-) + 4NO(3)(-) --> SO(4)(2-) + 4NO(2)(-) (Delta G(0) = -534 kJ mol(-1)). In a difference from other anaerobic sulfur-oxidizing bacteria, this bacterium was sensitive to NaCl; growth in medium containing more than 1% NaCl was negligible. When YK-1 was grown anaerobically in a sulfur-depleted inorganic medium overlaid with crude oil, sulfate was produced, corresponding to its growth. On the contrary, YK-1 could not utilize crude oil as a carbon source. These results suggest that the cluster 1 bacteria yielded energy for growth in oil storage cavities by oxidizing petroleum sulfur compounds. Based on its physiology, ecological interactions with other members of the groundwater community are discussed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1996-07-01
This module explains the Underground Storage Tank Regulatory Program established in 1988, that includes technical requirements to prevent, protect, and clean up releases from Underground Storage Tanks (USTs), as well as financial responsibility requirements to guarantee that UST owners and operators have enough money set aside to clean up releases and compensate third parties. Describes the Universe of USTs and the technical and financial requirements that apply to them. Defines underground storage tank and provides criteria for determining which USTs are subject to regulation. Discusses deadlines for upgrading tanks and the closure and corrective action requirements.
Aliso Canyon facility is giant among gas storage projects. [Underground
DOE Office of Scientific and Technical Information (OSTI.GOV)
Magruder, P.S.
1975-11-01
Alison Canyon, the largest and newest of the Southern California Gas Company's underground storage fields, has the capacity to provide nearly 50 percent of the company's firm peak day deliverability from systemwide storage. (LK)
Carbon sequestration in depleted oil shale deposits
Burnham, Alan K; Carroll, Susan A
2014-12-02
A method and apparatus are described for sequestering carbon dioxide underground by mineralizing the carbon dioxide with coinjected fluids and minerals remaining from the extraction shale oil. In one embodiment, the oil shale of an illite-rich oil shale is heated to pyrolyze the shale underground, and carbon dioxide is provided to the remaining depleted oil shale while at an elevated temperature. Conditions are sufficient to mineralize the carbon dioxide.
Environmental statutes, 1985 edition
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1985-01-01
All major environmental laws are incorporated into a single book. The complete text of each statute as currently amended is included with a detailed Table of Contents for your quick referral. Contents: Clean Air Act; Federal Water Pollution Control Act; National Environmental Policy Act; Noise Control Act; FIFRA; Marines Sanctuaries Act; Occupational Safety and Health Act; Resource Conservation and Recovery Act including the new Hazardous and Solid Waste Amendments of 1984 with the new Leaking Underground Storage Tank law; Safe Drinking Water Act; Toxic Substances Control Act; CERCLA/Superfund; and the Used Oil Recycling Act.
Winter fuels report, week ending November 12, 1993
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1993-11-18
The Winter Fuels Report is intended to provide concise, timely information to the industry, the press, policymakers, consumers, analysts, and State and local governments on the following topics: Distillate fuel oil net production, imports and stocks on a US level and for all Petroleum Administration for Defense Districts (PADD) and product supplied on a US level; propane net production, imports and stocks on a US level and for PADD`s I, II, and III; natural gas supply and disposition and underground storage for the US and consumption for all PADD`S; as well as selected National average prices; residential and wholesale pricingmore » data for heating oil and propane for those States participating in the joint Energy Information Administration (EIA)/State Heating Oil and Propane Program; crude oil and petroleum price comparisons for the US and selected cities; and a 6--10 Day, 30-Day, and 90-Day outlook for temperature and precipitation and US total heating degree-days by city.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-07
... Activities; Submission to OMB for Review and Approval; Comment Request; Underground Storage Tank: Information... docket, go to http://www.regulations.gov . Title: Underground Storage Tank: Information Request Letters... Storage Tanks: Technical and Financial Requirements, and State Program Approval Procedures.'' This...
Plowshare Program - American Atomic Bomb Tests For Industrial Applications
None
2018-01-16
The United States Atomic Energy Commission (AEC) established the Plowshare Program as a research and development activity to explore the technical and economic feasibility of using nuclear explosives for industrial applications. The reasoning was that the relatively inexpensive energy available from nuclear explosions could prove useful for a wide variety of peaceful purposes. The Plowshare Program began in 1958 and continued through 1975. Between December 1961 and May 1973, the United States conducted 27 Plowshare nuclear explosive tests comprising 35 individual detonations. Conceptually, industrial applications resulting from the use of nuclear explosives could be divided into two broad categories: 1) large-scale excavation and quarrying, where the energy from the explosion was used to break up and/or move rock; and 2) underground engineering, where the energy released from deeply buried nuclear explosives increased the permeability and porosity of the rock by massive breaking and fracturing. Possible excavation applications included: canals, harbors, highway and railroad cuts through mountains, open pit mining, construction of dams, and other quarry and construction-related projects. Underground nuclear explosion applications included: stimulation of natural gas production, preparation of leachable ore bodies for in situ leaching, creation of underground zones of fractured oil shale for in situ retorting, and formation of underground natural gas and petroleum storage reservoirs.
Plowshare Program - American Atomic Bomb Tests For Industrial Applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2012-04-22
The United States Atomic Energy Commission (AEC) established the Plowshare Program as a research and development activity to explore the technical and economic feasibility of using nuclear explosives for industrial applications. The reasoning was that the relatively inexpensive energy available from nuclear explosions could prove useful for a wide variety of peaceful purposes. The Plowshare Program began in 1958 and continued through 1975. Between December 1961 and May 1973, the United States conducted 27 Plowshare nuclear explosive tests comprising 35 individual detonations. Conceptually, industrial applications resulting from the use of nuclear explosives could be divided into two broad categories: 1)more » large-scale excavation and quarrying, where the energy from the explosion was used to break up and/or move rock; and 2) underground engineering, where the energy released from deeply buried nuclear explosives increased the permeability and porosity of the rock by massive breaking and fracturing. Possible excavation applications included: canals, harbors, highway and railroad cuts through mountains, open pit mining, construction of dams, and other quarry and construction-related projects. Underground nuclear explosion applications included: stimulation of natural gas production, preparation of leachable ore bodies for in situ leaching, creation of underground zones of fractured oil shale for in situ retorting, and formation of underground natural gas and petroleum storage reservoirs.« less
38. Launch Area, Underground Missile Storage Structure, detail of conduit ...
38. Launch Area, Underground Missile Storage Structure, detail of conduit service junction - NIKE Missile Battery PR-79, Launch Area, East Windsor Road south of State Route 101, Foster, Providence County, RI
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nummedal, Dag; Doran, Kevin; Sitchler, Alexis
2012-09-30
This multitask research project was conducted in anticipation of a possible future increase in industrial efforts at CO 2 storage in Colorado sedimentary basins. Colorado is already the home to the oldest Rocky Mountain CO 2 storage site, the Rangely Oil Field, where CO 2-EOR has been underway since the 1980s. The Colorado Geological Survey has evaluated storage options statewide, and as part of the SW Carbon Sequestration Partnership the Survey, is deeply engaged in and committed to suitable underground CO 2 storage. As a more sustainable energy industry is becoming a global priority, it is imperative to explore themore » range of technical options available to reduce emissions from fossil fuels. One such option is to store at least some emitted CO 2 underground. In this NETL-sponsored CO 2 sequestration project, the Colorado School of Mines and our partners at the University of Colorado have focused on a set of the major fundamental science and engineering issues surrounding geomechanics, mineralogy, geochemistry and reservoir architecture of possible CO 2 storage sites (not limited to Colorado). Those are the central themes of this final report and reported below in Tasks 2, 3, 4, and 6. Closely related to these reservoir geoscience issues are also legal, environmental and public acceptance concerns about pore space accessibility—as a precondition for CO 2 storage. These are addressed in Tasks 1, 5 and 7. Some debates about the future course of the energy industry can become acrimonius. It is true that the physics of combustion of hydrocarbons makes it impossible for fossil energy to attain a carbon footprint anywhere nearly as low as that of renewables. However, there are many offsetting benefits, not the least that fossil energy is still plentiful, it has a global and highly advanced distribution system in place, and the footprint that the fossil energy infrastructure occupies is orders of magnitude smaller than renewable energy facilities with equivalent energy capacity. Finally, inexpensive natural gas here in North America is pushing coal for electricity generation off the market, thus reducing US CO 2 emissions faster than any other large industrialized nation. These two big factors argue for renewed efforts to find technology solutions to reduce the carbon footprint (carbon dioxide as well as methane and trace gases) of conventional and unconventional oil and gas. One major such technology component is likely to be carbon capture, utilization and storage.« less
NASA Astrophysics Data System (ADS)
Jing, Wenjun; Zhao, Yan
2018-02-01
Stability is an important part of geotechnical engineering research. The operating experiences of underground storage caverns in salt rock all around the world show that the stability of the caverns is the key problem of safe operation. Currently, the combination of theoretical analysis and numerical simulation are the mainly adopts method of reserve stability analysis. This paper introduces the concept of risk into the stability analysis of underground geotechnical structure, and studies the instability of underground storage cavern in salt rock from the perspective of risk analysis. Firstly, the definition and classification of cavern instability risk is proposed, and the damage mechanism is analyzed from the mechanical angle. Then the main stability evaluating indicators of cavern instability risk are proposed, and an evaluation method of cavern instability risk is put forward. Finally, the established cavern instability risk assessment system is applied to the analysis and prediction of cavern instability risk after 30 years of operation in a proposed storage cavern group in the Huai’an salt mine. This research can provide a useful theoretical base for the safe operation and management of underground storage caverns in salt rock.
NASA Astrophysics Data System (ADS)
De Lucia, Marco; Pilz, Peter
2015-04-01
Underground gas storage is increasingly regarded as a technically viable option for meeting the energy demand and environmental targets of many industrialized countries. Besides the long-term CO2 sequestration, energy can be chemically stored in form of CO2/CH4/H2 mixtures, for example resulting from excess wind energy. A precise estimation of the impact of such gas mixtures on the mineralogical, geochemical and petrophysical properties of specific reservoirs and caprocks is crucial for site selection and optimization of storage depth. Underground gas storage is increasingly regarded as a technically viable option for meeting environmental targets and the energy demand through storage in form of H2 or CH4, i.e. resulting from excess wind energy. Gas storage in salt caverns is nowadays a mature technology; in regions where favorable geologic structures such as salt diapires are not available, however, gas storage can only be implemented in porous media such as depleted gas and oil reservoirs or suitable saline aquifers. In such settings, a significant amount of in-situ gas components such as CO2, CH4 (and N2) will always be present, making the CO2/CH4/H2 system of particular interest. A precise estimation of the impact of their gas mixtures on the mineralogical, geochemical and petrophysical properties of specific reservoirs and caprocks is therefore crucial for site selection and optimization of storage depth. In the framework of the collaborative research project H2STORE, the feasibility of industrial-scale gas storage in porous media in several potential siliciclastic depleted gas and oil reservoirs or suitable saline aquifers is being investigated by means of experiments and modelling on actual core materials from the evaluated sites. Among them are the Altmark depleted gas reservoir in Saxony-Anhalt and the Ketzin pilot site for CO2 storage in Brandenburg (Germany). Further sites are located in the Molasse basin in South Germany and Austria. In particular, two work packages hosted at the German Research Centre for Geosciences (GFZ) focus on the fluid-fluid and fluid-rock interactions triggered by CO2, H2 and their mixtures. Laboratory experiments expose core samples to hydrogen and CO2/hydrogen mixtures under site-specific conditions (temperatures up to 200 °C and pressure up to 300 bar). The resulting qualitative and, whereas possible, quantitative data are expected to ameliorate the precision of predictive geochemical and reactive transport modelling, which is also performed within the project. The combination of experiments, chemical and mineralogical analyses and models is needed to improve the knowledge about: (1) solubility model and mixing rule for multicomponent gas mixtures in high saline formation fluids: no data are namely available in literature for H2-charged gas mixtures in the conditions expected in the potential sites; (2) chemical reactivity of different mineral assemblages and formation fluids in a broad spectrum of P-T conditions and composition of the stored gas mixtures; (3) thermodynamics and kinetics of relevant reactions involving mineral dissolution or precipitation. The resulting amelioration of site characterization and the overall enhancement in understanding the potential processes will benefit the operational reliability, the ecological tolerance, and the economic efficiency of future energy storing plants, crucial aspects for public acceptance and for industrial investors.
37. Launch Area, Underground Missile Storage Structure, detail of personnel ...
37. Launch Area, Underground Missile Storage Structure, detail of personnel entrance VIEW NORTH - NIKE Missile Battery PR-79, Launch Area, East Windsor Road south of State Route 101, Foster, Providence County, RI
Review compliance deadlines for major provisions of the 2015 federal UST requirements, in the 15 states that have updated their state underground storage tank regulations to incorporate the revised requirements.
30 CFR 57.6102 - Explosive material storage practices.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Explosive material storage practices. 57.6102 Section 57.6102 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Explosives Storage-Surface and Underground §...
30 CFR 57.6102 - Explosive material storage practices.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Explosive material storage practices. 57.6102 Section 57.6102 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Explosives Storage-Surface and Underground §...
30 CFR 57.6102 - Explosive material storage practices.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Explosive material storage practices. 57.6102 Section 57.6102 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Explosives Storage-Surface and Underground §...
Federal Facilities Reports About Underground Storage Tank Compliance - 2005 Energy Policy Act
Find links to reports from 24 federal agencies regarding the compliance status of underground storage tanks owned or operated by the federal agencies or located on land managed by the federal agencies.
40. Launch Area, Underground Missile Storage Structure, detail of escape ...
40. Launch Area, Underground Missile Storage Structure, detail of escape hatch and decontamination shower VIEW WEST - NIKE Missile Battery PR-79, Launch Area, East Windsor Road south of State Route 101, Foster, Providence County, RI
Technical Guide for Addressing Petroleum Vapor Intrusion at Leaking Underground Storage Tank Sites
Review technical information for personnel EPA and implementing agencies for investigating and assessing petroleum vapor intrusion (PVI) at sites where petroleum hydrocarbons (PHCs) have been released from underground storage tanks (USTs).
Public Record About Underground Storage Tanks - 2005 Energy Policy Act
These grant guidelines implement the public record provision in Section 9002(d) of the Solid Waste Disposal Act, enacted by the Underground Storage Tank Compliance Act, part of the Energy Policy Act of 2005.
Natural gas monthly, August 1993
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1993-08-25
The Natural Gas Monthly (NGM) is prepared in the Data Operations Branch of the Reserves and Natural Gas Division, Office of Oil and Gas, Energy Information Administration (EIA), US Department of Energy (DOE). The NGM highhghts activities, events, and analyses of interest to public and private sector organizations associated with the natural gas industry. Volume and price data are presented each month for natural gas production, distribution, consumption, and interstate pipeline activities. Producer-related activities and underground storage data are also reported. From time to time, the NGM features articles designed to assist readers in using and interpreting natural gas information.
Numerical Simulation of Convective Heat and Mass Transfer in a Two-Layer System
NASA Astrophysics Data System (ADS)
Myznikova, B. I.; Kazaryan, V. A.; Tarunin, E. L.; Wertgeim, I. I.
The results are presented of mathematical and computer modeling of natural convection in the “liquid-gas” two-layer system, filling a vertical cylinder surrounded by solid heat conductive tract. The model describes approximately the conjugate heat and mass transfer in the underground oil product storage, filled partially by a hydrocarbon liquid, with natural gas layer above the liquid surface. The geothermal gradient in a rock mass gives rise to the intensive convection in the liquid-gas system. The consideration is worked out for laminar flows, laminar-turbulent transitional regimes, and developed turbulent flows.
Wilcox, Ralph
1995-01-01
The six sites investigated include silver recovery units; a buried caustic drain line; a neutralization pit; an evaporation/infiltration pond; the Manzano fire training area; and a waste oil underground storage tank. Environmental samples of soil, pond sediment, soil gas, and water and gas in floor drains were collected and analyzed. Field quality-control samples were also collected and analyzed in association with the environmental samples. The six sites were investigated because past or current activities could have resulted in contamination of soil, pond sediment, or water and sediment in drains.
Natural Gas Storage in the United States in 2001: A Current Assessment and Near-Term Outlook
2001-01-01
This report examines the large decline of underground natural gas storage inventories during the 2000-2001 heating season and the concern that the nation might run out of working gas in storage prior to the close of the heating season on March 31, 2001. This analysis also looks at the current profile and capabilities of the U.S. natural gas underground storage sector.
42. Launch Area, Underground Missile Storage Structure, detail of escape ...
42. Launch Area, Underground Missile Storage Structure, detail of escape hatch, elevator and air vent VIEW SOUTH - NIKE Missile Battery PR-79, Launch Area, East Windsor Road south of State Route 101, Foster, Providence County, RI
Inspecting Underground Storage Tanks - 2005 Energy Policy Act
these grant guidelines implement the inspection provisions in Sections 9005(c)(1) and 9005(c)(2) of the Solid Waste Disposal Act, enacted by the Underground Storage Tank Compliance Act, part of the Energy Policy Act of 2005.
36. Launch Area, Underground Missile Storage Structure, detail showing elevator, ...
36. Launch Area, Underground Missile Storage Structure, detail showing elevator, air ventilators and personnel entrance VIEW SOUTHEAST - NIKE Missile Battery PR-79, Launch Area, East Windsor Road south of State Route 101, Foster, Providence County, RI
Secondary Containment for Underground Storage Tank Systems - 2005 Energy Policy Act
These grant guidelines implement the secondary containment provision in Section 9003(i)(1) of the Solid Waste Disposal Act, enacted by the Underground Storage Tank Compliance Act, part of the Energy Policy Act of 2005.
This working paper examines the effect of increased inspection frequency occurring under the Energy Policy Act of 2005 on compliance with release detection and prevention requirements at underground storage tank facilities in Louisiana.
Popović, Višnja B; Petrović, Silvana D; Milenković, Marina T; Drobac, Milica M; Couladis, Maria A; Niketić, Marjan S
2015-01-01
The chemical composition and antimicrobial activity of essential oils of Laserpitium latifolium and L. ochridanum were investigated. The essential oils were isolated by steam distillation and characterized by GC-FID and GC/MS analyses. All essential oils were distinguished by high contents of monoterpenes, and α-pinene was the most abundant compound in the essential oils of L. latifolium underground parts and fruits (contents of 44.4 and 44.0%, resp.). The fruit essential oil was also rich in sabinene (26.8%). Regarding the L. ochridanum essential oils, the main constituents were limonene in the fruit oil (57.7%) and sabinene in the herb oil (25.9%). The antimicrobial activity of these essential oils as well as that of L. ochridanum underground parts, whose composition was reported previously, was tested by the broth-microdilution method against four Gram-positive and three Gram-negative bacteria and two Candida albicans strains. Except the L. latifolium underground-parts essential oil, the other investigated oils showed a high antimicrobial potential against Staphylococcus aureus, S. epidermidis, Micrococcus luteus, or Candida albicans (minimal inhibitory concentrations of 13.0-73.0 μg/ml), comparable to or even higher than that of thymol, which was used as reference compound. Copyright © 2015 Verlag Helvetica Chimica Acta AG, Zürich.
Global Pursuits: The Underground Railroad
ERIC Educational Resources Information Center
School Arts: The Art Education Magazine for Teachers, 2004
2004-01-01
This brief article describes Charles T. Webber's oil on canvas painting, "The Underground Railroad, 1893." The subject of this painting is the Underground Railroad, which today has become an American legend. The Underground Railroad was not a systematic means of transportation, but rather a secretive process that allowed fugitive slaves…
Method for maximizing shale oil recovery from an underground formation
Sisemore, Clyde J.
1980-01-01
A method for maximizing shale oil recovery from an underground oil shale formation which has previously been processed by in situ retorting such that there is provided in the formation a column of substantially intact oil shale intervening between adjacent spent retorts, which method includes the steps of back filling the spent retorts with an aqueous slurry of spent shale. The slurry is permitted to harden into a cement-like substance which stabilizes the spent retorts. Shale oil is then recovered from the intervening column of intact oil shale by retorting the column in situ, the stabilized spent retorts providing support for the newly developed retorts.
CHARACTERISTICS OF NON-PETROLEUM UNDERGROUND STORAGE TANKS
It is generally acknowledged that a small fraction of the total underground storage tank population is used to store chemicals. The detailed characteristics of these tanks, however, are not well understood. Additional information is required if competent decisions are to be made ...
Investigation of Corrosion-Influencing Factors in Underground Storage Tanks with Diesel Service
This paper summarized the research findings of an effort undertaken by EPA to understand possible causes and solutions to widespread reports of severe corrosion of metal components in underground storage tank systems storing diesel fuel since 2007.
10. Site D57 & 58L, Underground Missile Storage Structure, Type ...
10. Site D-57 & 58-L, Underground Missile Storage Structure, Type B, Plans, U.S. Army Corps of Engineers, 13 December 1953 - Newport NIKE Missile Battery D-57/58, Launch Area, Newport Road, Carleton, Monroe County, MI
Detection of abandoned underground storage tanks in rights-of-way with ground-penetrating radar.
DOT National Transportation Integrated Search
1995-01-01
Highway agencies need a simple, effective, nondestructive way to inspect certain properties in rights-of-way for the possible presence of abandoned underground storage tanks, without disturbing the ground, before actual construction begins. Overall, ...
Technical Guide For Addressing Petroleum Vapor Intrusion At Leaking Underground Storage Tank Sites
This document is intended for use at any site subject to petroleum contamination from underground storage tanks where vapor intrusion may be of potential concern. It is applicable to both residential and non-residential settings.
NASA Astrophysics Data System (ADS)
Xiaoqiang, W.; Li, J.; Daiqing, L.; Li, C.
2017-12-01
The surface deformation of underground gas reservoir with the change of injection pressure is an excellent opportunity to study the load response under the action of tectonic movement and controlled load. This paper mainly focuses on the elastic deformation of underground structure caused by the change of the pressure state of reservoir rock under the condition of the irregular change of pressure in the underground gas storage of Hutubi, the largest underground gas storage in Xinjiang, at the same time, it makes a fine study on the fault activities of reservoir and induced earthquakes along with the equilibrium instability caused by the reservoir. Based on the 34 deformation integrated observation points and 3 GPS continuous observation stations constructed in the underground gas storage area of Hutubi, using modern measurement techniques such as GPS observation, precise leveling survey, flow gravity observation and so on, combined with remote sensing technology such as InSAR, the 3d space-time sequence images of the surface of reservoir area under pressure change were obtained. Combined with gas well pressure, physical parameters and regional seismic geology and geophysical data, the numerical simulation and analysis of internal changes of reservoir were carried out by using elastic and viscoelastic model, the deformation mechanical relationship of reservoir was determined and the storage layer under controlled load was basically determined. This research is financially supported by National Natural Science Foundation of China (Grant No.41474016, 41474051, 41474097)
Subsidence Induced by Underground Extraction
Galloway, Devin L.
2016-01-01
Subsidence induced by underground extraction is a class of human-induced (anthropogenic) land subsidence that principally is caused by the withdrawal of subsurface fluids (groundwater, oil, and gas) or by the underground mining of coal and other minerals.
The role of the underground for massive storage of energy: a preliminary glance of the French case
NASA Astrophysics Data System (ADS)
Audigane, Pascal; Gentier, Sylvie; Bader, Anne-Gaelle; Beccaletto, Laurent; Bellenfant, Gael
2014-05-01
The question of storing energy in France has become of primary importance since the launch of a road map from the government which places in pole position this topic among seven major milestones to be challenged in the context of the development of innovative technology in the country. The European objective to reach 20% of renewables in the energy market, from which a large part would come from wind and solar power generation, raises several issues regarding the capacity of the grid to manage the various intermittent energy sources in line with the variability of the public demand and offer. These uncertainties are highly influenced by unpredictable weather and economic fluctuations. To facilitate the large-scale integration of variable renewable electricity sources in grids, massive energy storage is needed. In that case, electric energy storage techniques involving the use of underground are often under consideration as they offer a large storage capacity volume with a adapted potential of confining and the space required for the implantation. Among the panel of massive storage technologies, one can find (i) the Underground Pumped Hydro-Storage (UPHS) which are an adaptation of classical Pumped Hydro Storage system often connected with dam constructions, (ii) the compressed air storage (CAES) and (iii) the hydrogen storage from conversion of electricity into H2 and O2 by electrolysis. UPHS concept is based on using the potential energy between two water reservoirs positioned at different heights. Favorable natural locations like mountainous areas or cliffs are spatially limited given the geography of the territory. This concept could be extended with the integration of one of these reservoirs in an underground cavities (specifically mined or reuse of preexisting mines) to increase opportunities on the national territory. Massive storage based on compression and relaxation of air (CAES) requires high volume and confining pressure around the storage that exists naturally in the underground and which increases with depth. However, the move to an interesting efficiency requires that the heat generated during compression can be stored and used during expansion. This storage can be also underground. H2 underground storage is part of the "Power to gas" concept which allows for converting electricity into a gas available for either electrical or gas grid. Each of these techniques requires the selection of appropriate geological formations which contains specific characteristics in agreement with several criteria under consideration when choosing electric energy storage methods for application (lifetime, life cycle, discharge rate, environmental impact, public acceptance …). We propose in this paper a preliminary review of the potential massive electric energy storage capacities in France of using specific geological formations (salt, basement) and the various physical phenomena linked to the couple geology/technology. Several approaches and methodologies developed formerly with other applications (geothermal, CO2 storage, heat storage …) will be used to investigate mechanical integrity and environmental impacts associated to these innovative technologies.
Alternative treatment technology information center computer database system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sullivan, D.
1995-10-01
The Alternative Treatment Technology Information Center (ATTIC) computer database system was developed pursuant to the 1986 Superfund law amendments. It provides up-to-date information on innovative treatment technologies to clean up hazardous waste sites. ATTIC v2.0 provides access to several independent databases as well as a mechanism for retrieving full-text documents of key literature. It can be accessed with a personal computer and modem 24 hours a day, and there are no user fees. ATTIC provides {open_quotes}one-stop shopping{close_quotes} for information on alternative treatment options by accessing several databases: (1) treatment technology database; this contains abstracts from the literature on all typesmore » of treatment technologies, including biological, chemical, physical, and thermal methods. The best literature as viewed by experts is highlighted. (2) treatability study database; this provides performance information on technologies to remove contaminants from wastewaters and soils. It is derived from treatability studies. This database is available through ATTIC or separately as a disk that can be mailed to you. (3) underground storage tank database; this presents information on underground storage tank corrective actions, surface spills, emergency response, and remedial actions. (4) oil/chemical spill database; this provides abstracts on treatment and disposal of spilled oil and chemicals. In addition to these separate databases, ATTIC allows immediate access to other disk-based systems such as the Vendor Information System for Innovative Treatment Technologies (VISITT) and the Bioremediation in the Field Search System (BFSS). The user may download these programs to their own PC via a high-speed modem. Also via modem, users are able to download entire documents through the ATTIC system. Currently, about fifty publications are available, including Superfund Innovative Technology Evaluation (SITE) program documents.« less
EVALUATION OF VOLUMETRIC LEAK DETECTION METHODS USED IN UNDERGROUND STORAGE TANKS
In the spring and summer of 1987, the United States Environmental Protection Agency (EPA) evaluated the performance of 25 commercially available volumetric test methods for the detection of small leaks in underground storage tanks containing gasoline. Performance was estimated by...
A novel muon detector for borehole density tomography
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bonneville, Alain; Kouzes, Richard T.; Yamaoka, Jared
Muons can be used to image the density of materials through which they pass, including geological structures. Subsurface applications of the technology include tracking fluid migration during injection or production, with increasing concern regarding such timely issues as induced seismicity or chemical leakage into aquifers. Geological carbon storage, natural gas storage, enhanced oil recovery, compressed air storage, aquifer storage and recovery, waste water storage and oil and gas production are examples of application areas. It is thus crucial to monitor in quasi-real time the behavior of these fluids, and several monitoring techniques can be used. Among them, those that trackmore » density changes in the subsurface are the most relevant. Current density monitoring options include gravimetric data collection and active or passive seismic surveys. One alternative, or complement, to these methods is the development of a muon detector that is sufficiently compact and robust for deployment in a borehole. Such a muon detector can enable tomographic imaging of density structure to monitor small changes in density – a proxy for fluid migration – at depths up to 1500 m. Such a detector has been developed, and Monte Carlo modeling methods applied to simulate the anticipated detector response. The robustness of the detector design comes primarily from the use of polystyrene scintillating rods arrayed in alternating layers to provide a coordinate scheme. Testing and measurements using a prototype detector in the laboratory and shallow underground facilities demonstrated robust response. A satisfactory comparison with a large drift tube-based muon detector is also presented.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Weber, Paula D.; Rudeen, David Keith
2015-07-01
The United States Strategic Petroleum Reserve (SPR) maintains an underground storage system consisting of caverns that were leached or solution mined in four salt domes located near the Gulf of Mexico in Texas and Louisiana. The SPR comprises more than 60 active caverns containing approximately 700 million barrels of crude oil. Sandia National Labo- ratories (SNL) is the geotechnical advisor to the SPR. As the most pressing need at the inception of the SPR was to create and fill storage volume with oil, the decision was made to leach the caverns and fill them simultaneously (leach-fill). Therefore, A.J. Russo developedmore » SANSMIC in the early 1980s which allows for a transient oil-brine interface (OBI) making it possible to model leach-fill and withdrawal operations. As the majority of caverns are currently filled to storage capacity, the primary uses of SANSMIC at this time are related to the effects of small and large withdrawals, expansion of existing caverns, and projecting future pillar to diameter ratios. SANSMIC was identified by SNL as a priority candidate for qualification. This report continues the quality assurance (QA) process by documenting the "as built" mathematical and numerical models that comprise this document. The pro- gram flow is outlined and the models are discussed in detail. Code features that were added later or were not documented previously have been expounded. No changes in the code's physics have occurred since the original documentation (Russo, 1981, 1983) although recent experiments may yield improvements to the temperature and plume methods in the future.« less
40 CFR 282.102 - Puerto Rico State-Administered Program.
Code of Federal Regulations, 2010 CFR
2010-07-01
... part 281, subpart E. If the Commonwealth obtains approval for the revised requirements pursuant to... RCRA, 42 U.S.C. 6991 et seq. (A) Puerto Rico Statutory Requirements Applicable to the Underground Storage Tank Program, 1997. (B) Puerto Rico Regulatory Requirements Applicable to the Underground Storage...
MEASUREMENT AND ANALYSIS OF VAPOR SENSORS USED AT UNDERGROUND STORAGE TANK SITES
This report is a continuation of an investigation to quantify the operating characteristics of vapor sensor technologies used at underground storage tank (UST) sites. n the previous study (EPA/600/R-92/219) the sensitivity, selectivity, and response time to simulated UST environm...
VOLUMETRIC LEAK DETECTION IN LARGE UNDERGROUND STORAGE TANKS - VOLUME II: APPENDICES A-E
The program of experiments conducted at Griffiss Air Force Base was devised to expand the understanding of large underground storage tank behavior as it impacts the performance of volumetric leak detection testing. The report addresses three important questions about testing the ...
7 CFR 1955.57 - Real property containing underground storage tanks.
Code of Federal Regulations, 2014 CFR
2014-01-01
...; (3) Septic tanks; (4) Pipeline facilities (including gathering lines) regulated under; (i) The...) Storm water or wastewater collection systems; (7) Flow-through process tanks; (8) Liquid traps or... 7 Agriculture 14 2014-01-01 2014-01-01 false Real property containing underground storage tanks...
7 CFR 1955.57 - Real property containing underground storage tanks.
Code of Federal Regulations, 2011 CFR
2011-01-01
...; (3) Septic tanks; (4) Pipeline facilities (including gathering lines) regulated under; (i) The...) Storm water or wastewater collection systems; (7) Flow-through process tanks; (8) Liquid traps or... 7 Agriculture 14 2011-01-01 2011-01-01 false Real property containing underground storage tanks...
7 CFR 1955.57 - Real property containing underground storage tanks.
Code of Federal Regulations, 2012 CFR
2012-01-01
...; (3) Septic tanks; (4) Pipeline facilities (including gathering lines) regulated under; (i) The...) Storm water or wastewater collection systems; (7) Flow-through process tanks; (8) Liquid traps or... 7 Agriculture 14 2012-01-01 2012-01-01 false Real property containing underground storage tanks...
7 CFR 1955.57 - Real property containing underground storage tanks.
Code of Federal Regulations, 2013 CFR
2013-01-01
...; (3) Septic tanks; (4) Pipeline facilities (including gathering lines) regulated under; (i) The...) Storm water or wastewater collection systems; (7) Flow-through process tanks; (8) Liquid traps or... 7 Agriculture 14 2013-01-01 2013-01-01 false Real property containing underground storage tanks...
30 CFR 57.4460 - Storage of flammable liquids underground.
Code of Federal Regulations, 2010 CFR
2010-07-01
....4460 Section 57.4460 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and Control Flammable and Combustible Liquids and Gases § 57.4460 Storage of flammable...
Underground Storage Tanks on Indian Lands. Education Moderates an Environmental Threat.
ERIC Educational Resources Information Center
Hillger, Robert W.; Small, Matthew C.
1992-01-01
Describes problems related to old underground storage tanks (USTs) that may leak toxic contents, focusing on relevance for American Indian reservations. Discusses design, installation, and upgrading of UST systems; federal definitions and regulations; leak detection; legal responsibility; and education for public awareness. Includes Environmental…
This report supplements the previous State-of-the-Art Procedures and Equipment for Internal Inspection of Underground Storage Tanks published in 1991 by the EPA. The present report updates and provides descriptions of additional tank inspection technologies, specifically, noninva...
Field applications of three alternate technologies for assessing the suitability of underground storage tanks for upgrading by the addition of cathodic protection were observed and documented. The technologies were applied to five existing underground storage tanks that were slat...
VOLUMETRIC LEAK DETECTION IN LARGE UNDERGROUND STORAGE TANKS - VOLUME I
A set of experiments was conducted to determine whether volumetric leak detection system presently used to test underground storage tanks (USTs) up to 38,000 L (10,000 gal) in capacity could meet EPA's regulatory standards for tank tightness and automatic tank gauging systems whe...
NASA Astrophysics Data System (ADS)
Jackson, R. B.; Kang, M.
2016-12-01
Oil and gas extraction is expanding in the United States, attributable to the success of high-volume hydraulic fracturing, and associated wastewater disposal is increasing as a result. The United States currently has approximately 180,000 Class II injection wells associated with the oil and gas industry, more than 50,000 of them in California. Hydraulic fracturing and underground injection often occur many thousands of feet belowground. Previously, however, we documented shallow hydraulic fracturing and other oil and gas activities across the western United States in particular, including California and Wyoming. In eight CA counties, for example, as many as 19% and 35% of oil/gas activities have occurred directly in freshwater zones and USDWs, respectively (Kang and Jackson 2016 PNAS). Here we expand this analysis to examine the underground injection control program and accompanying hydrogeologic variables found in California and elsewhere.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Medeiros, Michael
Pacific Gas & Electric Company (PG&E) conducted a project to explore the viability of underground compressed air energy storage (CAES) technology. CAES uses low-cost, off-peak electricity to compress air into a storage system in an underground space such as a rock formation or salt cavern. When electricity is needed, the air is withdrawn and used to drive a generator for electricity production.
Technical Feasibility of Compressed Air Energy Storage (CAES) Utilizing a Porous Rock Reservoir
DOE Office of Scientific and Technical Information (OSTI.GOV)
Medeiros, Michael; Booth, Robert; Fairchild, James
Pacific Gas & Electric Company (PG&E) conducted a project to explore the viability of underground compressed air energy storage (CAES) technology. CAES uses low-cost, off-peak electricity to compress air into a storage system in an underground space such as a rock formation or salt cavern. When electricity is needed, the air is withdrawn and used to drive a generator for electricity production.
40 CFR 282.87 - Oregon State-Administered Program.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 28 2012-07-01 2012-07-01 false Oregon State-Administered Program. 282... (CONTINUED) APPROVED UNDERGROUND STORAGE TANK PROGRAMS Approved State Programs § 282.87 Oregon State-Administered Program. (a) The State of Oregon is approved to administer and enforce an underground storage tank...
40 CFR 282.87 - Oregon State-Administered Program.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 27 2014-07-01 2014-07-01 false Oregon State-Administered Program. 282... (CONTINUED) APPROVED UNDERGROUND STORAGE TANK PROGRAMS Approved State Programs § 282.87 Oregon State-Administered Program. (a) The State of Oregon is approved to administer and enforce an underground storage tank...
40 CFR 282.87 - Oregon State-Administered Program.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 28 2013-07-01 2013-07-01 false Oregon State-Administered Program. 282... (CONTINUED) APPROVED UNDERGROUND STORAGE TANK PROGRAMS Approved State Programs § 282.87 Oregon State-Administered Program. (a) The State of Oregon is approved to administer and enforce an underground storage tank...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Julyk, L.J.
1995-09-01
In-structure response spectra for dome mounted equipment on underground waste storage tanks at the Hanford Site are developed on the basis of recent soil-structure-interaction analyses. Recommended design spectra are provided for various locations on the tank dome.
40 CFR 282.61 - Hawaii State-Administered Program.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 26 2010-07-01 2010-07-01 false Hawaii State-Administered Program. 282... (CONTINUED) APPROVED UNDERGROUND STORAGE TANK PROGRAMS Approved State Programs § 282.61 Hawaii State-Administered Program. (a) The State of Hawaii's underground storage tank program is approved in lieu of the...
40 CFR 282.50 - Alabama State-Administered Program.
Code of Federal Regulations, 2010 CFR
2010-07-01
... and Recovery Act of 1976 (RCRA), as amended, 42 U.S.C. 6991 et seq. The State's program, as... Alabama underground storage tank program concurrently with this notice and it will be effective on March... to be effective on March 25, 1997. Copies of Alabama's underground storage tank program may be...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Webb, R.A.
The need to have accurate petroleum measurement is obvious. Petroleum measurement is the basis of commerce between oil producers, royalty owners, oil transporters, refiners, marketers, the Department of Revenue, and the motoring public. Furthermore, petroleum measurements are often used to detect operational problems or unwanted releases in pipelines, tanks, marine vessels, underground storage tanks, etc. Therefore, consistent, accurate petroleum measurement is an essential part of any operation. While there are several methods and different types of equipment used to perform petroleum measurement, the basic process stays the same. The basic measurement process is the act of comparing an unknown quantity,more » to a known quantity, in order to establish its magnitude. The process can be seen in a variety of forms; such as measuring for a first-down in a football game, weighing meat and produce at the grocery, or the use of an automobile odometer.« less
Numerical modeling of underground storage system for natural gas
NASA Astrophysics Data System (ADS)
Ding, J.; Wang, S.
2017-12-01
Natural gas is an important type of base-load energy, and its supply needs to be adjusted according to different demands in different seasons. For example, since natural gas is increasingly used to replace coal for winter heating, the demand for natural gas in winter is much higher than that in other seasons. As storage systems are the essential tools for balancing seasonal supply and demand, the design and simulation of natural gas storage systems form an important research direction. In this study, a large-scale underground storage system for natural gas is simulated based on theoretical analysis and finite element modeling.It is proven that the problem of axi-symmetric Darcy porous flow of ideal gas is governed by the Boussinesq equation. In terms of the exact solution to the Boussinesq equation, the basic operating characteristics of the underground storage system is analyzed, and it is demonstrated that the propagation distance of the pore pressure is proportional to the 1/4 power of the mass flow rate and to the 1/2 power of the propagation time. This quantitative relationship can be used to guide the overall design of natural gas underground storage systems.In order to fully capture the two-way coupling between pore pressure and elastic matrix deformation, a poro-elastic finite element model for natural gas storage is developed. Based on the numerical model, the dynamic processes of gas injection, storage and extraction are simulated, and the corresponding time-dependent surface deformations are obtained. The modeling results not only provide a theoretical basis for real-time monitoring for the operating status of the underground storage system through surface deformation measurements, but also demonstrate that a year-round balance can be achieved through periodic gas injection and extraction.This work is supported by the CAS "100 talents" Program and the National Natural Science Foundation of China (41371090).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Medeiros, Michael
Pacific Gas & Electric Company (PG&E) conducted a project to explore the viability of underground compressed air energy storage (CAES) technology. CAES uses low-cost, off-peak electricity to compress air into a storage system in an underground space such as a rock formation or salt cavern. When electricity is needed, the air is withdrawn and used to drive a generator for electricity production.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Medeiros, Michael
Pacific Gas & Electric Company (PG&E) conducted a project to explore the viability of underground compressed air energy storage (CAES) technology. CAES uses low-cost, off-peak electricity to compress air into a storage system in an underground space such as a rock formation or salt cavern. When electricity is needed, the air is withdrawn and used to drive a generator for electricity production.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Medeiros, Michael
Pacific Gas & Electric Company (PG&E) conducted a project to explore the viability of underground compressed air energy storage (CAES) technology. CAES uses low-cost, off-peak electricity to compress air into a storage system in an underground space such as a rock formation or salt cavern. When electricity is needed, the air is withdrawn and used to drive a generator for electricity production.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Medeiros, Michael
Pacific Gas & Electric Company (PG&E) conducted a project to explore the viability of underground compressed air energy storage (CAES) technology. CAES uses low-cost, off-peak electricity to compress air into a storage system in an underground space such as a rock formation or salt cavern. When electricity is needed, the air is withdrawn and used to drive a generator for electricity production.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Medeiros, Michael
Pacific Gas & Electric Company (PG&E) conducted a project to explore the viability of underground compressed air energy storage (CAES) technology. CAES uses low-cost, off-peak electricity to compress air into a storage system in an underground space such as a rock formation or salt cavern. When electricity is needed, the air is withdrawn and used to drive a generator for electricity production.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Medeiros, Michael
Pacific Gas & Electric Company (PG&E) conducted a project to explore the viability of underground compressed air energy storage (CAES) technology. CAES uses low-cost, off-peak electricity to compress air into a storage system in an underground space such as a rock formation or salt cavern. When electricity is needed, the air is withdrawn and used to drive a generator for electricity production.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Medeiros, Michael
Pacific Gas & Electric Company (PG&E) conducted a project to explore the viability of underground compressed air energy storage (CAES) technology. CAES uses low-cost, off-peak electricity to compress air into a storage system in an underground space such as a rock formation or salt cavern. When electricity is needed, the air is withdrawn and used to drive a generator for electricity production.
Code of Federal Regulations, 2010 CFR
2010-07-01
...) FEDERAL MANAGEMENT REGULATION REAL PROPERTY 80-SAFETY AND ENVIRONMENTAL MANAGEMENT Safety and Environmental Management Underground Storage Tanks § 102-80.40 What are Federal agencies' responsibilities... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false What are Federal...
EPA's 1988 regulations concerning USTs are contained in 40 CFR Part 280, 40 CFR Part 281 and 40 CFR Parts 282.50-282.105 and divided into three sections: technical requirements, financial responsibility requirements, and state program approval objectives.
18 CFR 157.215 - Underground storage testing and development.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 18 Conservation of Power and Water Resources 1 2012-04-01 2012-04-01 false Underground storage testing and development. 157.215 Section 157.215 Conservation of Power and Water Resources FEDERAL ENERGY... not exceed the amount specified in Table II as adjusted pursuant to § 157.208(d). These costs shall...
18 CFR 157.215 - Underground storage testing and development.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 18 Conservation of Power and Water Resources 1 2014-04-01 2014-04-01 false Underground storage testing and development. 157.215 Section 157.215 Conservation of Power and Water Resources FEDERAL ENERGY... not exceed the amount specified in Table II as adjusted pursuant to § 157.208(d). These costs shall...
18 CFR 157.215 - Underground storage testing and development.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 18 Conservation of Power and Water Resources 1 2011-04-01 2011-04-01 false Underground storage testing and development. 157.215 Section 157.215 Conservation of Power and Water Resources FEDERAL ENERGY... not exceed the amount specified in Table II as adjusted pursuant to § 157.208(d). These costs shall...
18 CFR 157.215 - Underground storage testing and development.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 18 Conservation of Power and Water Resources 1 2013-04-01 2013-04-01 false Underground storage testing and development. 157.215 Section 157.215 Conservation of Power and Water Resources FEDERAL ENERGY... not exceed the amount specified in Table II as adjusted pursuant to § 157.208(d). These costs shall...
Composition of pyrolysis gas from oil shale at various stages of heating
NASA Astrophysics Data System (ADS)
Martemyanov, S. M.; Bukharkin, A. A.; Koryashov, I. A.; Ivanov, A. A.
2017-05-01
Underground, the pyrolytic conversion of an oil shale in the nearest future may become an alternative source of a fuel gas and a synthetic oil. The main scientific problem in designing this technology is to provide a methodology for determination of the optimal mode of heating the subterranean formation. Such a methodology must allow predicting the composition of the pyrolysis products and the energy consumption at a given heating rate of the subterranean formation. The paper describes the results of heating of the oil shale fragments in conditions similar to the underground. The dynamics of composition of the gaseous products of pyrolysis are presented and analyzed.
11. Photocopy of drawing of underground missile storage and elevator ...
11. Photocopy of drawing of underground missile storage and elevator controls from 'Procedures and Drills for the NIKE Ajax System,' Department of the Army Field Manual, FM-44-80 from Institute for Military History, Carlisle Barracks, Carlisle, PA, 1956 - NIKE Missile Battery PR-79, East Windsor Road south of State Route 101, Foster, Providence County, RI
Using Geographic Information Systems (GIS), the vulnerability of ground water supplies to contamination from underground storage tanks (USTs) was assessed. The analysis was conducted for the 48 contiguous states, and then again for groups of states corresponding to the EPA Regio...
Johnson, W.H.
1971-02-02
A method is described for constructing a lined underground cavity. The process includes the steps of securing a casing in a borehole by grouting, underreaming the casing, filling the underreamed region with additional grouting, and then drilling through and underreaming the added grouting, thereby forming a room having a lining formed of the grouting. By using a structurally strong grouting that is impervious to water, the resulting room is waterproof and is suitable for on-site storage of an atomic device and its associated equipment prior to an underground atomic event. Such cavities also have other uses; for example, the cavities may be made very deep and used for storage of various fluids such as natural gas storage. (5 claims)
NASA Astrophysics Data System (ADS)
Fesko, Steve
1996-11-01
Eaton operates a corporate aircraft hanger facility in Battle Creek, Michigan. Tests showed that two underground storage tanks leaked. Investigation confirmed this release discharged several hundred gallons of Jet A kerosene into the soil and groundwater. The oil moved downward approximately 30 feet and spread laterally onto the water table. Test results showed kerosene in the adsorbed, free and dissolved states. Eaton researched and investigated three clean-up options. They included pump and treat, dig and haul and bioremediation. Jet fuel is composed of readily biodegradable hydrocarbon chains. This fact coupled with the depth to groundwater and geologic setting made bioremediation the low cost and most effective alternative. A recovery well was installed at the leading edge of the dissolved contamination. A pump moved water from this well into a nutrient addition system. Nutrients added included nitrogen, phosphorous and potassium. Additionally, air was sparged into the water. The water was discharged into an infiltration gallery installed when the underground storage tanks were removed. Water circulated between the pump and the infiltration basin in a closed loop fashion. This oxygenated, nutrient rich water actively and aggressively treated the soils between the bottom of the gallery and the top of the groundwater and the groundwater. The system began operating in August of 1993 and reduced jet fuel to below detection levels. In August of 1995 The State of Michigan issued a clean closure declaration to the site.
Livermore study says oil leaks not severe
DOE Office of Scientific and Technical Information (OSTI.GOV)
Patrick, L.
The Petroleum Marketers Association of America (PMAA), which is working to reform the federal Leaking Underground Storage Tank program, got some strong ammunition last month. A study that the Lawrence Livermore National Laboratory performed for the California State Water Resources Control Board has found that the environmental threat of leaks is not as severe as formerly thought. The study said: such leaks rarely jeopardize drinking water; fuel hydrocarbons have limited impacts on health, the environment, and groundwater; and cleanups often are done contrary to the knowledge and experience gained from prior remediations. As a result of the study, Gov. Petemore » Wilson ordered California cleanups halted at sites more than 250 feet from drinking water supplies.« less
12. Photocopy of drawing of underground missile storage, elevator and ...
12. Photocopy of drawing of underground missile storage, elevator and ground-level launchers from 'Procedures and Drills for the NIKE Ajax System,' Department of the Army Field Manual, FM-44-80 from Institute for Military History, Carlisle Barracks, Carlisle, PA, 1956 - NIKE Missile Battery PR-79, East Windsor Road south of State Route 101, Foster, Providence County, RI
Basic features of waste material storage in underground space in relation to geomechanics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Konecny, P.
1994-12-31
It is logical to consider utilizing underground cavities for waste material disposal because, during mining, great volumes of rock materials are extracted, and underground hollow areas and communicating workings are created that can, in general, be utilized for waste disposal. Additionally, in many cases, underground waste disposal favorably supports mining process technology (for instance, application of power plant fly ash and preparation plant tailings as hardened backfill). However, it is necessary to give particular attention to the preparation, operation, and isolation of underground tip areas; errors and, in extreme cases, emergencies in underground tips are generally more difficult to dealmore » with than those in surface tips. A tip place constructed underground becomes part of the rock massif; therefore, all natural laws that rule the rock massif must be respected. Of course, such an approach requires knowledge of processes and natural regularities that will occur in rock strata where tip places have been constructed. Such knowledge is gained through familiarity with contemporary geomechanical science. The paper discusses basic geomechanical principles of underground waste disposal; geomechanical aspects of rock massif evaluation in view of waste material storage in mine workings; and plans for an experimental project for waste disposal in the Dul Ostrava underground mine.« less
Buildings may be at risk from Petroleum Vapor Intrusion (PVI) when they overlie petroleum hydrocarbon contamination in the unsaturated zone or dissolved in groundwater. The U.S. EPA Office of Underground Storage Tanks (OUST) is preparing Guidance for Addressing Petroleum Vapor I...
GIS analysis of available data to identify regions in the U.S. where shallow ground water supplies are particularly vulnerable to contamination by releases of biofuels from underground storage tanks. In this slide presentation, GIS was used to perform a simple numerical and ...
This asset includes an inventory of programmatic information, including policies and guidance, training course materials and Leaking Underground Storage Tanks (LUST) Trust Fund information. This documentation is used by states, territories, tribes and private parties to implement the Underground Storage Tank (UST) program. It also includes analysis of the laws and regulations that govern USTs, and policies and guidance for implementing the UST program developed by EPA in consultation with state and territorial UST programs.
18 CFR 157.213 - Underground storage field facilities.
Code of Federal Regulations, 2011 CFR
2011-04-01
... storage reservoir and within the buffer area; (4) A detailed description of present storage operations and..., provided the storage facility's certificated physical parameters—including total inventory, reservoir pressure, reservoir and buffer boundaries, and certificated capacity remain unchanged—and provided...
30 CFR 817.180 - Utility installations.
Code of Federal Regulations, 2010 CFR
2010-07-01
... PERMANENT PROGRAM PERFORMANCE STANDARDS PERMANENT PROGRAM PERFORMANCE STANDARDS-UNDERGROUND MINING ACTIVITIES § 817.180 Utility installations. All underground mining activities shall be conducted in a manner...; oil, gas, and coal-slurry pipelines, railroads; electric and telephone lines; and water and sewage...
Impact craters - Are they useful?
NASA Astrophysics Data System (ADS)
Masaitis, V. L.
1992-03-01
Terrestrial impact craters are important geological and geomorphological objects that are significant not only for scientific research but for industrial and commercial purposes. The structures may contain commercial minerals produced directly by thermodynamic transformation of target rocks (including primary forming ores) controlled by some morphological, structural or lithological factors and exposed in the crater. Iron and uranium ores, nonferrous metals, diamonds, coals, oil shales, hydrocarbons, mineral waters and other raw materials occur in impact craters. Impact morphostructures may be used for underground storage of gases or liquid waste material. Surface craters may serve as reservoirs for hydropower. These ring structures may be of value to society in other ways. Scientific investigation of them is especially important in comparative planetology, terrestrial geology and in other divisions of the natural sciences.
Corapcioglu, M. Yavuz; Baehr, Arthur L.
1987-01-01
A mathematical model is developed to describe the fate of hydrocarbon constituents of petroleum products introduced to soils as an immiscible liquid from sources such as leaking underground storage tanks and ruptured pipelines. The problem is one of multiphase transport (oil (immiscible), air, and water phases) of a reactive contaminant with constituents such as benzene, toluene, and xylene found in refined petroleum products like gasoline. In the unsaturated zone, transport of each constituent can occur as a solute in the water phase, vapor in the air phase, and as an unaltered constituent in the oil phase. Additionally, the model allows for adsorption. Molecular transformations, microbially mediated or abiotic, are incorporated as sink terms in the conservation of mass equations. An equilibrium approximation, applicable to any immiscible organic contaminant is applied to partition constituent mass between the air, oil, water, and adsorbed phases for points in the region where the oil phase exists. Outside the oil plume the equilibrium approximation takes on a simpler form to partition constituent mass between the air, water, and adsorbed phases only. Microbial degradation of petroleum products is first discussed in a general model, then the conservation of mass equation for oxygen is incorporated into the analysis which takes advantage of the key role played by oxygen in the metabolism of hydrocarbon utilizing microbes in soil environments. Approximations to two subproblems, oil plume establishment in the unsaturated zone, and solute and vapor transport subsequent to immiscible plume establishment are then developed from the general model.
Indian Country Leaking Underground Storage Tanks, Region 9, 2016
This GIS dataset contains point features that represent Leaking Underground Storage Tanks in US EPA Region 9 Indian Country. This dataset contains facility name and locational information, status of LUST case, operating status of facility, inspection dates, and links to No Further Action letters for closed LUST cases. This database contains 1230 features, with 289 features having a LUST status of open, closed with no residual contamination, or closed with residual contamination.
30 CFR 75.1700 - Oil and gas wells.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Oil and gas wells. 75.1700 Section 75.1700... MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1700 Oil and gas wells. [Statutory Provisions] Each operator of a coal mine shall take reasonable measures to locate oil and gas wells...
30 CFR 75.1700 - Oil and gas wells.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Oil and gas wells. 75.1700 Section 75.1700... MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1700 Oil and gas wells. [Statutory Provisions] Each operator of a coal mine shall take reasonable measures to locate oil and gas wells...
30 CFR 75.1700 - Oil and gas wells.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Oil and gas wells. 75.1700 Section 75.1700... MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1700 Oil and gas wells. [Statutory Provisions] Each operator of a coal mine shall take reasonable measures to locate oil and gas wells...
30 CFR 75.1700 - Oil and gas wells.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Oil and gas wells. 75.1700 Section 75.1700... MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1700 Oil and gas wells. [Statutory Provisions] Each operator of a coal mine shall take reasonable measures to locate oil and gas wells...
30 CFR 75.1700 - Oil and gas wells.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Oil and gas wells. 75.1700 Section 75.1700... MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1700 Oil and gas wells. [Statutory Provisions] Each operator of a coal mine shall take reasonable measures to locate oil and gas wells...
Emulsions in porous media: From single droplet behavior to applications for oil recovery.
Perazzo, Antonio; Tomaiuolo, Giovanna; Preziosi, Valentina; Guido, Stefano
2018-06-01
Emulsions are suspensions of droplets ubiquitous in oil recovery from underground reservoirs. Oil is typically trapped in geological porous media where emulsions are either formed in situ or injected to elicit oil mobilization and thus enhance the amount of oil recovered. Here, we briefly review basic concepts on geometrical and wetting features of porous media, including thin film stability and fluids penetration modes, which are more relevant for oil recovery and oil-contaminated aquifers. Then, we focus on the description of emulsion flow in porous media spanning from the behaviour of single droplets to the collective flow of a suspension of droplets, including the effect of bulk and interfacial rheology, hydrodynamic and physico-chemical interactions. Finally, we describe the particular case of emulsions used in underground porous media for enhanced oil recovery, thereby discussing some perspectives of future work. Although focused on oil recovery related topics, most of the insights we provide are useful towards remediation of oil-contaminated aquifers and for a basic understanding of emulsion flow in any kind of porous media, such as biological tissues. Copyright © 2018 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Kissinger, A.; Walter, L.; Darcis, M.; Flemisch, B.; Class, H.
2012-04-01
Global climate change, shortage of resources and the resulting turn towards renewable sources of energy lead to a growing demand for the utilization of subsurface systems. Among these competing uses are Carbon Capture and Storage (CCS), geothermal energy, nuclear waste disposal, "renewable" methane or hydrogen storage as well as the ongoing production of fossil resources like oil, gas, and coal. Besides competing among themselves, these technologies may also create conflicts with essential public interests like water supply. For example, the injection of CO2 into the underground causes an increase in pressure reaching far beyond the actual radius of influence of the CO2 plume, potentially leading to large amounts of displaced salt water. Finding suitable sites is a demanding task for several reasons. Natural systems as opposed to technical systems are always characterized by heterogeneity. Therefore, parameter uncertainty impedes reliable predictions towards capacity and safety of a site. State of the art numerical simulations combined with stochastic approaches need to be used to obtain a more reliable assessment of the involved risks and the radii of influence of the different processes. These simulations may include the modeling of single- and multiphase non-isothermal flow, geo-chemical and geo-mechanical processes in order to describe all relevant physical processes adequately. Stochastic approaches have the aim to estimate a bandwidth of the key output parameters based on uncertain input parameters. Risks for these different underground uses can then be made comparable with each other. Along with the importance and the urgency of the competing processes this may lead to a more profound basis for a decision. Communicating risks to stake holders and a concerned public is crucial for the success of finding a suitable site for CCS (or other subsurface utilization). We present and discuss first steps towards an approach for addressing the issue of competitive utilization of the subsurface and the required process of communication between scientists, engineers, policy makers, and societies.
NASA Astrophysics Data System (ADS)
Nagel, T.; Böttcher, N.; Görke, U. J.; Kolditz, O.
2014-12-01
The design process of geotechnical installations includes the application of numerical simulation tools for safety assessment, dimensioning and long term effectiveness estimations. Underground salt caverns can be used for the storage of natural gas, hydrogen, oil, waste or compressed air. For their design one has to take into account fluctuating internal pressures due to different levels of filling, the stresses imposed by the surrounding rock mass, irregular geometries and possibly heterogeneous material properties [3] in order to estimate long term cavern convergence as well as locally critical wall stresses. Constitutive models applied to rock salt are usually viscoplastic in nature and most often based on a Burgers-type rheological model extended by non-linear viscosity functions and/or plastic friction elements. Besides plastic dilatation, healing and damage are sometimes accounted for as well [2]. The scales of the geotechnical system to be simulated and the laboratory tests from which material parameters are determined are vastly different. The most common material testing modalities to determine material parameters in geoengineering are the uniaxial and the triaxial compression tests. Some constitutive formulations in widespread use are formulated based on equivalent rather than tensorial quantities valid under these specific test conditions and are subsequently applied to heterogeneous underground systems and complex 3D load cases. We show here that this procedure is inappropriate and can lead to erroneous results. We further propose alternative formulations of the constitutive models in question that restore their validity under arbitrary loading conditions. For an efficient numerical simulation, the discussed constitutive models are integrated locally with a Newton-Raphson algorithm that directly provides the algorithmically consistent tangent matrix for the global Newton iteration of the displacement based finite element formulation. Finally, the finite element implementations of the proposed constitutive formulations are employed to simulate an underground salt cavern used for compressed air energy storage with OpenGeoSys [1]. Transient convergence and stress fields are evaluated for typical fluctuating operation pressure regimes.
Assessment of feasible strategies for seasonal underground hydrogen storage in a saline aquifer
NASA Astrophysics Data System (ADS)
Sáinz-García, Alvaro; Abarca, Elena; Rubí, Violeta; Grandia, Fidel
2017-04-01
Renewable energies are unsteady, which results in temporary mismatches between demand and supply. The conversion of surplus energy to hydrogen and its storage in geological formations is one option to balance this energy gap. This study evaluates the feasibility of seasonal storage of hydrogen produced from wind power in Castilla-León region (northern Spain). A 3D multiphase numerical model is used to test different extraction well configurations during three annual injection-production cycles in a saline aquifer. Results demonstrate that underground hydrogen storage in saline aquifers can be operated with reasonable recovery ratios. A maximum hydrogen recovery ratio of 78%, which represents a global energy efficiency of 30%, has been estimated. Hydrogen upconing emerges as the major risk on saline aquifer storage. However, shallow extraction wells can minimize its effects. Steeply dipping geological structures are key for an efficient hydrogen storage.
NASA Astrophysics Data System (ADS)
Pujades, Estanislao; Bodeux, Sarah; Orban, Philippe; Dassargues, Alain
2016-04-01
Pumped Storage Hydropower (PSH) plants can be used to manage the production of electrical energy according to the demand. These plants allow storing and generating electricity during low and high demand energy periods, respectively. Nevertheless, PSH plants require a determined topography because two reservoirs located at different heights are needed. At sites where PSH plants cannot be constructed due to topography requirements (flat regions), Underground Pumped Storage Hydropower (UPSH) plants can be used to adjust the electricity production. These plants consist in two reservoirs, the upper one is located at the surface (or at shallow depth) while the lower one is underground (or deeper). Abandoned open pit mines can be used as lower reservoirs but these are rarely isolated. As a consequence, UPSH plants will interact with surrounding aquifers exchanging groundwater. Groundwater seepage will modify hydraulic head inside the underground reservoir affecting global efficiency of the UPSH plant. The influence on the plant efficiency caused by the interaction between UPSH plants and aquifers will depend on the aquifer parameters, underground reservoir properties and pumping and injection characteristics. The alteration of the efficiency produced by the groundwater exchanges, which has not been previously considered, is now studied numerically. A set of numerical simulations are performed to establish in terms of efficiency the effects of groundwater exchanges and the optimum conditions to locate an UPSH plant.
Value of Underground Storage in Today's Natural Gas Industry, The
1995-01-01
This report explores the significant and changing role of storage in the industry by examining the value of natural gas storage; short-term relationships between prices, storage levels, and weather; and some longer term impacts of the Federal Energy Regulatory Commission's (FERC) Order 636.
30 CFR 57.6102 - Explosive material storage practices.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Explosive material storage practices. 57.6102... Storage-Surface and Underground § 57.6102 Explosive material storage practices. (a) Explosive material... instructions and the date-plant-shift code are maintained with the product. Storage—Surface Only ...
30 CFR 57.6102 - Explosive material storage practices.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Explosive material storage practices. 57.6102... Storage-Surface and Underground § 57.6102 Explosive material storage practices. (a) Explosive material... instructions and the date-plant-shift code are maintained with the product. Storage—Surface Only ...
30 CFR 57.4160 - Underground electric substations and liquid storage facilities.
Code of Federal Regulations, 2010 CFR
2010-07-01
..., DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and Control Prohibitions/precautions/housekeeping § 57.4160... noncombustible materials with equivalent fire protection characteristics. ...
30 CFR 57.6309 - Fuel oil requirements for ANFO.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Fuel oil requirements for ANFO. 57.6309 Section... Transportation-Surface and Underground § 57.6309 Fuel oil requirements for ANFO. (a) Liquid hydrocarbon fuels with flash points lower than that of No. 2 diesel oil (125 °F) shall not be used to prepare ammonium...
Rabadán, Adrián; Álvarez-Ortí, Manuel; Pardo, José Emilio; Alvarruiz, Andrés
2018-09-01
Chemical composition and stability parameters of three cold-pressed nut oils (almond, walnut and pistachio) were monitored for up to 16 months of storage at 5 °C, 10 °C, 20 °C and room temperature. Freshly pressed pistachio oil had lower peroxide value than almond oil and higher induction period than almond and walnut oils, indicating a higher stability. The peroxide values increased faster at room temperature than at lower temperatures during the storage time, and the highest increase was for pistachio oil stored at room temperature exposed to daylight. The induction period decreased for all three nut oils during the storage time, regardless of the storage conditions. Pistachio oil remained the most stable oil at the end of the storage time, followed by almond oil. The percentage of polyunsaturated fatty acids decreased slightly throughout the storage. Copyright © 2018 Elsevier Ltd. All rights reserved.
100-N Area underground storage tank closures
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rowley, C.A.
1993-08-01
This report describes the removal/characterization actions concerning underground storage tanks (UST) at the 100-N Area. Included are 105-N-LFT, 182-N-1-DT, 182-N-2-DT, 182-N-3-DT, 100-N-SS-27, and 100-N-SS-28. The text of this report gives a summary of remedial activities. In addition, correspondence relating to UST closures can be found in Appendix B. Appendix C contains copies of Unusual Occurrence Reports, and validated sampling data results comprise Appendix D.
Oldenburg, Curtis M. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Earth Sciences Division
2018-05-07
Summer Lecture Series 2009: Climate change provides strong motivation to reduce CO2 emissions from the burning of fossil fuels. Carbon dioxide capture and storage involves the capture, compression, and transport of CO2 to geologically favorable areas, where its injected into porous rock more than one kilometer underground for permanent storage. Oldenburg, who heads Berkeley Labs Geologic Carbon Sequestration Program, will focus on the challenges, opportunities, and research needs of this innovative technology.
30 CFR 57.6800 - Storage facilities.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Storage facilities. 57.6800 Section 57.6800...-Surface and Underground § 57.6800 Storage facilities. When repair work which could produce a spark or flame is to be performed on a storage facility— (a) The explosive material shall be moved to another...
75 FR 17707 - Arlington Storage Company, LLC; Notice of Filing
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-07
... Storage Company, LLC; Notice of Filing March 30, 2010. Take notice that on March 24, 2010, Arlington Storage Company, LLC (ASC), Two Brush Creek Boulevard, Kansas City, Missouri 64112, filed an application... existing underground natural gas storage facility located in Schuyler County, New York known as the Seneca...
30 CFR 57.6800 - Storage facilities.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Storage facilities. 57.6800 Section 57.6800...-Surface and Underground § 57.6800 Storage facilities. When repair work which could produce a spark or flame is to be performed on a storage facility— (a) The explosive material shall be moved to another...
30 CFR 57.6800 - Storage facilities.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Storage facilities. 57.6800 Section 57.6800...-Surface and Underground § 57.6800 Storage facilities. When repair work which could produce a spark or flame is to be performed on a storage facility— (a) The explosive material shall be moved to another...
30 CFR 57.6800 - Storage facilities.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Storage facilities. 57.6800 Section 57.6800...-Surface and Underground § 57.6800 Storage facilities. When repair work which could produce a spark or flame is to be performed on a storage facility— (a) The explosive material shall be moved to another...
30 CFR 57.6800 - Storage facilities.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Storage facilities. 57.6800 Section 57.6800...-Surface and Underground § 57.6800 Storage facilities. When repair work which could produce a spark or flame is to be performed on a storage facility— (a) The explosive material shall be moved to another...
40 CFR 144.22 - Existing Class II enhanced recovery and hydrocarbon storage wells.
Code of Federal Regulations, 2010 CFR
2010-07-01
... and hydrocarbon storage wells. 144.22 Section 144.22 Protection of Environment ENVIRONMENTAL... of Underground Injection by Rule § 144.22 Existing Class II enhanced recovery and hydrocarbon storage wells. (a) An existing Class II enhanced recovery or hydrocarbon storage injection well is authorized by...
40 CFR 144.22 - Existing Class II enhanced recovery and hydrocarbon storage wells.
Code of Federal Regulations, 2011 CFR
2011-07-01
... and hydrocarbon storage wells. 144.22 Section 144.22 Protection of Environment ENVIRONMENTAL... of Underground Injection by Rule § 144.22 Existing Class II enhanced recovery and hydrocarbon storage wells. (a) An existing Class II enhanced recovery or hydrocarbon storage injection well is authorized by...
30 CFR 57.6309 - Fuel oil requirements for ANFO.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Fuel oil requirements for ANFO. 57.6309 Section 57.6309 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND... Transportation-Surface and Underground § 57.6309 Fuel oil requirements for ANFO. (a) Liquid hydrocarbon fuels...
30 CFR 57.6309 - Fuel oil requirements for ANFO.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Fuel oil requirements for ANFO. 57.6309 Section 57.6309 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND... Transportation-Surface and Underground § 57.6309 Fuel oil requirements for ANFO. (a) Liquid hydrocarbon fuels...
Modeling the Impact of Deformation on Unstable Miscible Displacements in Porous Media
NASA Astrophysics Data System (ADS)
Santillán, D.; Cueto-Felgueroso, L.
2014-12-01
Coupled flow and geomechanics is a critical research challenge in engineering and the geosciences. The simultaneous flow of two or more fluids with different densities or viscosities through deformable media is ubiquitous in environmental, industrial, and biological processes, including the removal of non-aqueous phase liquids from underground water bodies, the geological storage of CO2, and current challenges in energy technologies, such as enhanced geothermal systems, unconventional hydrocarbon resources or enhanced oil recovery techniques. Using numerical simulation, we study the interplay between viscous-driven flow instabilities (viscous fingering) and rock mechanics, and elucidate the structure of the displacement patterns as a function of viscosity contrast, injection rate and rock mechanical properties. Finally, we discuss the role of medium deformation on transport and mixing processes in porous media.
Fuel Storage Tanks at FAA Facilities: Order 1050.15A
DOT National Transportation Integrated Search
1997-04-30
The Federal Aviation Administration (FAA) has over 4,000 fuel storage tanks (FST) in its : inventory. Most of these FSTs are underground storage tanks (UST) that contain fuel for : emergency backup generators providing secondary power to air navigati...
Construction of VLCC marine oil storage cost index system
NASA Astrophysics Data System (ADS)
Li, Yuan; Li, Yule; Lu, Jinshu; Wu, Wenfeng; Zhu, Faxin; Chen, Tian; Qin, Beichen
2018-04-01
VLCC as the research object, the basic knowledge of VLCC is summarized. According to the phenomenon that VLCC is applied to offshore oil storage gradually, this paper applies the theoretical analysis method to analyze the excess capacity from VLCC, the drop of oil price, the aging VLCC is more suitable for offshore storage The paper analyzes the reason of VLCC offshore oil storage from three aspects, analyzes the cost of VLCC offshore storage from the aspects of manpower cost and shipping cost, and constructs the cost index system of VLCC offshore oil storage.
40 CFR 279.22 - Used oil storage.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 27 2011-07-01 2011-07-01 false Used oil storage. 279.22 Section 279...) STANDARDS FOR THE MANAGEMENT OF USED OIL Standards for Used Oil Generators § 279.22 Used oil storage. Used oil generators are subject to all applicable Spill Prevention, Control and Countermeasures (40 CFR...
40 CFR 279.22 - Used oil storage.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 26 2010-07-01 2010-07-01 false Used oil storage. 279.22 Section 279...) STANDARDS FOR THE MANAGEMENT OF USED OIL Standards for Used Oil Generators § 279.22 Used oil storage. Used oil generators are subject to all applicable Spill Prevention, Control and Countermeasures (40 CFR...
Abandoned underground storage tank location using fluxgate magnetic surveying: A case study
Van Biersel, T. P.; Bristoll, B.C.; Taylor, R.W.; Rose, J.
2002-01-01
In 1993, during the removal of a diesel and a gasoline underground storage tank at the municipal garage of the Village of Kohler, Sheboygan County, Wisconsin, soil testing revealed environmental contamination at the site. A site investigation revealed the possibility of a second on-site source of petroleum contamination. Limited historical data and the present usage of structures within the suspected source area precluded the use of most invasive sampling methods and most geophysical techniques. A fluxgate magnetometer survey, followed by confirmatory excavation, was conducted at the site. The fluxgate magnetometer survey identified nine possible magnetic anomalies within the 18 ?? 25 m area. The subsequent excavation near the anomalies revealed the presence of five paired and two individual 2000 L underground storage tanks. The fluxgate magnetometer survey, although affected by the proximity of buildings, was able to detect the buried tanks within 3 m of the brick structures, using a 1.5 ?? 1.5 m sampling array.
Ontogenesis and functions of saxophone stem in Acrocomia aculeata (Arecaceae)
e Souza, Joyce Nascimento; Ribeiro, Leonardo Monteiro; Mercadante-Simões, Maria Olívia
2017-01-01
Background and Aims The underground saxophone stem systems produced by seedlings of certain palm species show peculiar growth patterns and distinctive morphologies, although little information is available concerning their development and function. We studied the ontogenesis of the saxophone stem in Acrocomia aculeata, an important neotropical oleaginous palm, and sought to experimentally define its function. Methods Morpho-anatomical evaluations were performed during 240 d on seedlings using traditional methodologies. The tuberous region of the structure was submitted to histochemical tests and evaluated by transmission electron microscopy. The aerial portions of 130 1- to 3-year-old greenhouse plants were removed and their continuous growth capacity was evaluated after 30 d. Severed saxophone stems were also stored at room temperature (average 25 °C) for up to 90 d and then cultured for 60 d to evaluate root and shoot emission. Key Results The development of the saxophone stem is distinct from other underground systems previously described, and involves three processes: growth and curvature of the cotyledonary petiole, expansion and curvature of the hypocotyl, and expansion of the plumule internodes. The tuberous region stores water and starch, as well as lesser amounts of mucilage and oil. Growth of the aerial portion occurred in 84 % of the separated saxophone stems and in 53 % of the stems held in storage. Conclusions The saxophone stem represents an important adaptation of A. aculeata to anthropogenically impacted and/or dry environments by promoting the burial of both the shoot meristem and storage reserves, which allows the continuous growth of aerial organs. PMID:28028018
ERIC Educational Resources Information Center
Bednar, Barbara A.
1990-01-01
The harm to human health and our environment caused by leaking underground storage tanks can be devastating. Schools can meet new federal waste management standards by instituting daily inventory monitoring, selecting a reliable volumetric testing company, locating and repairing leaks promptly, and removing and installing tanks appropriately. (MLH)
Fuel storage tanks at FAA facilities : Order 1050.15A : executive summary.
DOT National Transportation Integrated Search
1997-04-30
The Federal Aviation Administration (FAA) has over 4,000 fuel storage tanks (FST) in its inventory. Most of these FSTs are underground storage tanks (UST) that contain fuel for emergency backup generators providing secondary power to air navigational...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-20
... operation of natural gas facilities in Sheridan County and Campbell County, Wyoming and modification of underground storage facilities at its Baker Storage Reservoir in Fallon County, Montana. The details of... firm storage deliverability from its Baker Storage Reservoir that it will use to make up for declining...
Concept for Underground Disposal of Nuclear Waste
NASA Technical Reports Server (NTRS)
Bowyer, J. M.
1987-01-01
Packaged waste placed in empty oil-shale mines. Concept for disposal of nuclear waste economically synergistic with earlier proposal concerning backfilling of oil-shale mines. New disposal concept superior to earlier schemes for disposal in hard-rock and salt mines because less uncertainty about ability of oil-shale mine to contain waste safely for millenium.
GEOLOGIC CARBON STORAGE: UNDERSTANDING THE RULES OF THE UNDERGROUND
The paper discusses the geologic sequestration (GS) of carbon dioxide (CO2), an emerging option for carbon management. Few studies have explored the regulatory needs of GS or compared these needs with regulations governing underground injection on the U.S. mainland. Our treatment...
COKE STORAGE HOPPER LOCATED OUTSIDE THE MALLEABLE FOUNDRY SHOWING LOADING ...
COKE STORAGE HOPPER LOCATED OUTSIDE THE MALLEABLE FOUNDRY SHOWING LOADING DEVICE THAT USED A SKIP CAR TO FILL THE HOPPER FROM UNDERGROUND GRAVITY-FED STORAGE AREAS FROM INCOMING RAILROAD CARS. - Stockham Pipe & Fittings Company, 4000 Tenth Avenue North, Birmingham, Jefferson County, AL
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1992-05-20
The 22,000-acre Otis National Guard/Camp Edwards site is a former military vehicle maintenance facility on Cape Cod, Massachusetts, within the Massachusetts Military Reservation (MMR). The Area of Contamination Chemical Spill Area Number 4 (AOC CS-4) plume extends 11,000 feet and is located 1.1 miles from the southern boundary of MMR. Wastes and equipment handled at AOC CS-4 included oils, solvents, antifreeze, battery electrolytes, paint, and waste fuels. Additionally, the northern portion of AOC CS-4 was used as a storage yard for wastes generated by shops and laboratories operating at MMR. Liquid wastes were stored in containers or underground storage tanksmore » (USTs) in an unbermed area or deposited in USTs designated for motor gasoline. The ROD addresses OU2, the interim action for MMR AOC CS-4 ground water to prevent further down gradient migration of the contaminants. The primary contaminants of concern affecting the ground water are VOCs, including PCE and TCE.« less
Systematic Evaluation of Salt Cavern Well Integrity
NASA Astrophysics Data System (ADS)
Roberts, B. L.; Lord, D. L.; Lord, A. S.; Bettin, G.; Sobolik, S. R.; Park, B. Y.
2017-12-01
The U.S. Strategic Petroleum Reserve (SPR) holds a reserve of crude oil ( 700 million barrels) to help ease any interruptions in oil import to the United States. The oil is stored in a set of 63 underground caverns distributed across four sites along the U.S. Gulf Coast. The caverns were solution mined into salt domes at each of the four sites. The plastic nature of the salt is beneficial for the storage of crude oil as it heals any fractures that may occur in the salt. The SPR is responsible for operating and maintaining the nearly 120 wells used to access the storage caverns over operational lifetimes spanning decades. Salt creep can induce deformation of the well casing which must be remediated to insure cavern and well integrity. This is particularly true at the interface between the plastic salt and the rigid caprock. The Department of Energy, the SPR Management and Operations contractor, and Sandia National Laboratories has developed a multidimensional well-grading system for the salt cavern access wells. This system is designed to assign numeric grades to each well indicating its risk of losing integrity and remediation priority. The system consists of several main components which themselves may consist of sub-components. The main components consider such things as salt cavern pressure history, results from geomechanical simulations modeling salt deformation, and measurements of well casing deformation due to salt creep. In addition, the geology of the salt domes and their overlying caprock is also included in the grading. These multiple factors are combined into summary values giving the monitoring and remediation priority for each well. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology and Engineering Solutions of Sandia LLC, a wholly owned subsidiary of Honeywell International Inc. for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-NA0003525.
25 CFR 211.22 - Leases for subsurface storage of oil or gas.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 25 Indians 1 2011-04-01 2011-04-01 false Leases for subsurface storage of oil or gas. 211.22... TRIBAL LANDS FOR MINERAL DEVELOPMENT How To Acquire Leases § 211.22 Leases for subsurface storage of oil... subsurface storage of oil or gas, irrespective of the lands from which production is initially obtained. The...
25 CFR 211.22 - Leases for subsurface storage of oil or gas.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 25 Indians 1 2012-04-01 2011-04-01 true Leases for subsurface storage of oil or gas. 211.22... TRIBAL LANDS FOR MINERAL DEVELOPMENT How To Acquire Leases § 211.22 Leases for subsurface storage of oil... subsurface storage of oil or gas, irrespective of the lands from which production is initially obtained. The...
25 CFR 211.22 - Leases for subsurface storage of oil or gas.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 25 Indians 1 2010-04-01 2010-04-01 false Leases for subsurface storage of oil or gas. 211.22... TRIBAL LANDS FOR MINERAL DEVELOPMENT How To Acquire Leases § 211.22 Leases for subsurface storage of oil... subsurface storage of oil or gas, irrespective of the lands from which production is initially obtained. The...
25 CFR 211.22 - Leases for subsurface storage of oil or gas.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 25 Indians 1 2014-04-01 2014-04-01 false Leases for subsurface storage of oil or gas. 211.22... TRIBAL LANDS FOR MINERAL DEVELOPMENT How To Acquire Leases § 211.22 Leases for subsurface storage of oil... subsurface storage of oil or gas, irrespective of the lands from which production is initially obtained. The...
25 CFR 211.22 - Leases for subsurface storage of oil or gas.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 25 Indians 1 2013-04-01 2013-04-01 false Leases for subsurface storage of oil or gas. 211.22... TRIBAL LANDS FOR MINERAL DEVELOPMENT How To Acquire Leases § 211.22 Leases for subsurface storage of oil... subsurface storage of oil or gas, irrespective of the lands from which production is initially obtained. The...
NASA Astrophysics Data System (ADS)
Park, Gyuryeong; Wang, Sookyun; Lee, Minhee; Um, Jeong-Gi; Kim, Seon-Ok
2017-04-01
The storage of CO2 in underground geological formation such as deep saline aquifers or depleted oil and gas reservoirs is one of the most promising technologies for reducing the atmospheric CO2 release. The processes in geological CO2 storage involves injection of supercritical CO2 (scCO2) into porous formations saturated with brine and initiates CO2 flooding with immiscible displacement. The CO2 migration and porewater displacement within geological formations, and , consequentially, the storage efficiency are governed by the interaction of fluid and rock properties and are affected by the interfacial tension, capillarity, and wettability in supercritical CO2-brine-mineral systems. This study aims to observe the displacement pattern and estimate storage efficiency by using micromodels. This study aims to conduct scCO2 injection experiments for visualization of distribution of injected scCO2 and residual porewater in transparent pore networks on microfluidic chips under high pressure and high temperature conditions. In order to quantitatively analyze the porewater displacement by scCO2 injection under geological CO2 storage conditions, the images of invasion patterns and distribution of CO2 in the pore network are acquired through a imaging system with a microscope. The results from image analysis were applied in quantitatively investigating the effects of major environmental factors and scCO2 injection methods on porewater displacement process by scCO2 and storage efficiency. The experimental observation results could provide important fundamental information on capillary characteristics of reservoirs and improve our understanding of CO2 sequestration progress.
40 CFR 280.33 - Repairs allowed.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Practice for the Interior Lining of Existing Steel Underground Storage Tanks”; and National Leak Prevention Association Standard 631, “Spill Prevention, Minimum 10 Year Life Extension of Existing Steel Underground... pipe sections and fittings that have released product as a result of corrosion or other damage must be...
40 CFR 280.33 - Repairs allowed.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Practice for the Interior Lining of Existing Steel Underground Storage Tanks”; and National Leak Prevention Association Standard 631, “Spill Prevention, Minimum 10 Year Life Extension of Existing Steel Underground... pipe sections and fittings that have released product as a result of corrosion or other damage must be...
High-Level Radioactive Waste: Safe Storage and Ultimate Disposal.
ERIC Educational Resources Information Center
Dukert, Joseph M.
Described are problems and techniques for safe disposal of radioactive waste. Degrees of radioactivity, temporary storage, and long-term permanent storage are discussed. Included are diagrams of estimated waste volumes to the year 2000 and of an artist's conception of a permanent underground disposal facility. (SL)
Jabeur, Hazem; Zribi, Akram; Abdelhedi, Ridha; Bouaziz, Mohamed
2015-02-15
The present paper accounts for the study of the storage of Chemlali olive fruits at two conditions of limited aerobiosis: in closed plastic bags and in open perforated plastic boxes for different periods before oil extraction. The ultimate objective is to investigate the effect of the container type of the postharvest fruit storage on the deterioration of the olive oil quality. The results have shown that the oil quality of Chemlali olives deteriorated more rapidly during fruit storage in closed plastic bags than in perforated plastic boxes. Therefore, the use of perforated plastic boxes is recommended for keeping the olives for longer periods of storage. The repeated measures analysis of variance of all parameters analyzed indicated that the olive oil quality is mainly affected by the olives storage conditions (containers type and storage periods). Finally, blends of extra-virgin olive oil and mildly deodorized low-quality olive oils can be detected by their alkyl esters concentrations. Copyright © 2014 Elsevier Ltd. All rights reserved.
30 CFR 57.6960 - Mixing of explosive material.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Mixing of explosive material. 57.6960 Section... General Requirements-Underground Only § 57.6960 Mixing of explosive material. (a) The mixing of... to the hazards associated with the mixing of the bulk explosive material underground. (b) Storage...
30 CFR 57.6960 - Mixing of explosive material.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Mixing of explosive material. 57.6960 Section... General Requirements-Underground Only § 57.6960 Mixing of explosive material. (a) The mixing of... to the hazards associated with the mixing of the bulk explosive material underground. (b) Storage...
30 CFR 57.6960 - Mixing of explosive material.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Mixing of explosive material. 57.6960 Section... General Requirements-Underground Only § 57.6960 Mixing of explosive material. (a) The mixing of... to the hazards associated with the mixing of the bulk explosive material underground. (b) Storage...
30 CFR 57.6960 - Mixing of explosive material.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Mixing of explosive material. 57.6960 Section... General Requirements-Underground Only § 57.6960 Mixing of explosive material. (a) The mixing of... to the hazards associated with the mixing of the bulk explosive material underground. (b) Storage...
30 CFR 57.6960 - Mixing of explosive material.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Mixing of explosive material. 57.6960 Section... General Requirements-Underground Only § 57.6960 Mixing of explosive material. (a) The mixing of... to the hazards associated with the mixing of the bulk explosive material underground. (b) Storage...
30 CFR 75.1106-3 - Storage of liquefied and nonliquefied compressed gas cylinders; requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES...; requirements. (a) Liquefied and nonliquefied compressed gas cylinders stored in an underground coal mine shall... falling material, contact with power lines and energized electrical equipment, heat from welding, cutting...
29 CFR 1926.904 - Storage of explosives and blasting agents.
Code of Federal Regulations, 2010 CFR
2010-07-01
..., electric blasting caps, detonating primers, and primed cartridges shall not be stored in the same magazine... feet of explosives and detonator storage magazine. (d) No explosives or blasting agents shall be... least two modes of exit have been provided. (e) Permanent underground storage magazines shall be at...
Alternative designs for petroleum product storage tanks for groundwater protection.
Oke Adeleke, Samson
In developing countries, there are numerous occurrences of petroleum product spillage in groundwater. The current practice of burying storage tanks beneath the surface without adequate safety devices facilitates this phenomenon. Underground tanks rust and leak, and spilled petroleum products migrate downward. The movement of the oil in the soil depends on its viscosity and quantity, the permeability of the soil/rock, and the presence of fractures within the rock. The oil spreads laterally in the form of a thin pancake due to its lower specific gravity, and soluble components dissolve in water. The pollution plume of petroleum products and dissolved phases moves in the direction of groundwater flow in the aquifer within the pores of soil and sediments or along fractures in basement complex areas. Most communities reply heavily on groundwater for potable and industrial supplies. However, the sustainability of this resource is under threat in areas where there are filling stations as a result of significant groundwater contamination from petroleum product spillage. Drinking water becomes unpalatable when it contains petroleum products in low concentrations, and small quantities may contaminate large volumes of water. Considering the losses incurred from spillage, the cost of cleaning the aquifer, and the fact that total cleansing and attenuation is impossible, the need to prevent spillage and if it happens to prevent it from getting into the groundwater system is of paramount importance. This paper proposes alternative design procedures with a view to achieving these objectives.
A GIS-based 3D online information system for underground energy storage in northern Germany
NASA Astrophysics Data System (ADS)
Nolde, Michael; Malte, Schwanebeck; Ehsan, Biniyaz; Rainer, Duttmann
2015-04-01
We would like to present the concept and current state of development of a GIS-based 3D online information system for underground energy storage. Its aim is to support the local authorities through pre-selection of possible sites for thermal, electrical and substantial underground energy storages. Since the extension of renewable energies has become legal requirement in Germany, the underground storing of superfluously produced green energy (such as during a heavy wind event) in the form of compressed air, gas or heated water has become increasingly important. However, the selection of suitable sites is a complex task. The presented information system uses data of geological features such as rock layers, salt domes and faults enriched with attribute data such as rock porosity and permeability. This information is combined with surface data of the existing energy infrastructure, such as locations of wind and biogas stations, powerline arrangement and cable capacity, and energy distribution stations. Furthermore, legal obligations such as protected areas on the surface and current underground mining permissions are used for the process of pre-selecting sites suitable for energy storage. Not only the current situation but also prospective scenarios, such as expected growth in produced amount of energy are incorporated in the system. While the process of pre-selection itself is completely automated, the user has full control of the weighting of the different factors via the web interface. The system is implemented as an online 3D server GIS environment, so that it can easily be utilized in any web browser. The results are visualized online as interactive 3d graphics. The information system is implemented in the Python programming language in combination with current Web standards, and is build using only free and open source software. It is being developed at Kiel University as part of the ANGUS+ project (lead by Prof. Sebastian Bauer) for the federal state of Schleswig-Holstein in northern Germany.
40 CFR 52.987 - Control of hydrocarbon emissions.
Code of Federal Regulations, 2013 CFR
2013-07-01
... control systems on a 37,500 barrel capacity crude oil storage tank at Cities Service Pipeline Company, Oil... a 25,000 barrel capacity crude oil storage tank at Cities Service Pipeline Company, Haynesville... barrel capacity crude oil storage tank at Cities Service Pipeline Company, Summerfield, Louisiana with...
40 CFR 52.987 - Control of hydrocarbon emissions.
Code of Federal Regulations, 2014 CFR
2014-07-01
... control systems on a 37,500 barrel capacity crude oil storage tank at Cities Service Pipeline Company, Oil... a 25,000 barrel capacity crude oil storage tank at Cities Service Pipeline Company, Haynesville... barrel capacity crude oil storage tank at Cities Service Pipeline Company, Summerfield, Louisiana with...
40 CFR 52.987 - Control of hydrocarbon emissions.
Code of Federal Regulations, 2012 CFR
2012-07-01
... control systems on a 37,500 barrel capacity crude oil storage tank at Cities Service Pipeline Company, Oil... a 25,000 barrel capacity crude oil storage tank at Cities Service Pipeline Company, Haynesville... barrel capacity crude oil storage tank at Cities Service Pipeline Company, Summerfield, Louisiana with...
NASA Astrophysics Data System (ADS)
Bodeux, Sarah; Pujades, Estanislao; Orban, Philippe; Dassargues, Alain
2016-04-01
The energy framework is currently characterized by an expanding use of renewable sources. However, their intermittence could not afford a stable production according to the energy demand. Pumped Storage Hydroelectricity (PSH) is an efficient possibility to store and release electricity according to the demand needs. Because of the topographic and environmental constraints of classical PSH, new potential suitable sites are rare in countries whose topography is weak or with a high population density. Nevertheless, an innovative alternative is to construct Underground Pumped Storage Hydroelectricity (UPSH) plants by using old underground mine works as lower reservoir. In that configuration, large amount of pumped or injected water in the underground cavities would impact the groundwater system. A representative UPSH facility is used to numerically determine the interactions with surrounding aquifers Different scenarios with varying parameters (hydrogeological and lower reservoir characteristics, boundaries conditions and pumping/injection time-sequence) are computed. Analysis of the computed piezometric heads around the reservoir allows assessing the magnitude of aquifer response and the required time to achieve a mean pseudo-steady state under cyclic solicitations. The efficiency of the plant is also evaluated taking the leakage into the cavity into account. Combining these two outcomes, some criterions are identified to assess the feasibility of this type of projects within potential old mine sites from a hydrogeological point of view.
Literature Survey on Long-Term Storage of Petroleum Products, Artillery Storage Program
1946-05-31
Oil .... . o . . . 70 ADDITION AGENTS . •• . ....... ....... 72 Oxidation Inhibitors 73 Oxidation Inhibitors in Turbine Oils • . . 73 Oxidation...also been considered. The oils found qost suitable for storage media should probably be closely related to transformer or turbine oils. In addition to...from those who have been using transformer anid turbine oils, and there are reports on these oils aind the changes which liave occurred over a period
1. PAINT AND OIL STORAGE SHED, FRONT, LOOKING SOUTHWEST. ...
1. PAINT AND OIL STORAGE SHED, FRONT, LOOKING SOUTHWEST. - NIKE Missile Base SL-40, Paint & Oil Storage Shed, North end of base, northwest of Mess Hall & south of Basketball Court, Hecker, Monroe County, IL
Code of Federal Regulations, 2010 CFR
2010-07-01
... and hydrocarbon storage wells authorized by rule. 147.304 Section 147.304 Protection of Environment... UNDERGROUND INJECTION CONTROL PROGRAMS Colorado § 147.304 Existing Class II enhanced recovery and hydrocarbon... the owner or operator of an existing enhanced recovery or hydrocarbon storage well may not be in...
Code of Federal Regulations, 2011 CFR
2011-07-01
... and hydrocarbon storage wells authorized by rule. 147.904 Section 147.904 Protection of Environment... UNDERGROUND INJECTION CONTROL PROGRAMS Kentucky § 147.904 Existing Class II enhanced recovery and hydrocarbon... the owner or operator of an existing enhanced recovery or hydrocarbon storage well may not be in...
Code of Federal Regulations, 2010 CFR
2010-07-01
... and hydrocarbon storage wells authorized by rule. 147.104 Section 147.104 Protection of Environment... UNDERGROUND INJECTION CONTROL PROGRAMS Alaska § 147.104 Existing Class II enhanced recovery and hydrocarbon... the owner or operator of an existing enhanced recovery or hydrocarbon storage well may not be in...
Code of Federal Regulations, 2010 CFR
2010-07-01
... and hydrocarbon storage wells authorized by rule. 147.904 Section 147.904 Protection of Environment... UNDERGROUND INJECTION CONTROL PROGRAMS Kentucky § 147.904 Existing Class II enhanced recovery and hydrocarbon... the owner or operator of an existing enhanced recovery or hydrocarbon storage well may not be in...
Code of Federal Regulations, 2010 CFR
2010-07-01
... and hydrocarbon storage wells authorized by rule. 147.1354 Section 147.1354 Protection of Environment... UNDERGROUND INJECTION CONTROL PROGRAMS Montana § 147.1354 Existing Class II enhanced recovery and hydrocarbon... existing enhanced recovery or hydrocarbon storage well may not be in compliance with the requirements of...
Code of Federal Regulations, 2011 CFR
2011-07-01
... and hydrocarbon storage wells authorized by rule. 147.1354 Section 147.1354 Protection of Environment... UNDERGROUND INJECTION CONTROL PROGRAMS Montana § 147.1354 Existing Class II enhanced recovery and hydrocarbon... existing enhanced recovery or hydrocarbon storage well may not be in compliance with the requirements of...
Code of Federal Regulations, 2011 CFR
2011-07-01
... and hydrocarbon storage wells authorized by rule. 147.104 Section 147.104 Protection of Environment... UNDERGROUND INJECTION CONTROL PROGRAMS Alaska § 147.104 Existing Class II enhanced recovery and hydrocarbon... the owner or operator of an existing enhanced recovery or hydrocarbon storage well may not be in...
Code of Federal Regulations, 2011 CFR
2011-07-01
... and hydrocarbon storage wells authorized by rule. 147.304 Section 147.304 Protection of Environment... UNDERGROUND INJECTION CONTROL PROGRAMS Colorado § 147.304 Existing Class II enhanced recovery and hydrocarbon... the owner or operator of an existing enhanced recovery or hydrocarbon storage well may not be in...
Carbon Dioxide Tucked into Basalt Converts to Rock
DOE Office of Scientific and Technical Information (OSTI.GOV)
McGrail, Pete
2016-11-18
Carbon Sequestration or storing carbon dioxide underground may be one approach to reducing atmospheric levels of the greenhouse gas. Storing it in basalt formations creates a chemical reaction in which the CO2 is transformed into a mineral similar to limestone enabling permanent storage underground. A field study by researchers at the Department of Energy’s Pacific Northwest National Laboratory shows that chemical happens quickly. Within two years, CO2 injected underground in Washington state had converted to the carbonate mineral ankerite.
Carbon Dioxide Tucked into Basalt Converts to Rock
McGrail, Pete
2018-06-13
Carbon Sequestration or storing carbon dioxide underground may be one approach to reducing atmospheric levels of the greenhouse gas. Storing it in basalt formations creates a chemical reaction in which the CO2 is transformed into a mineral similar to limestone enabling permanent storage underground. A field study by researchers at the Department of Energyâs Pacific Northwest National Laboratory shows that chemical happens quickly. Within two years, CO2 injected underground in Washington state had converted to the carbonate mineral ankerite.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Farid, E.E.; Nour, M.H.
1996-11-01
In 1988 a major onshore production facility was producing oil from eight formations in six oil fields located in the western desert of Egypt. Two of these formations include active water drive reservoirs, in addition; three reservoirs at that date were receiving water injection to enhance oil recovery. To handle the increasing volumes of the produced water (which is contaminated with oil, production chemicals and other pollutants), three alternatives were investigated: (1) Injection into disposal wells. (2) Dumping in surface disposal pits. (3) Re-injection to waterflood some oil reservoirs. The investigation revealed that the first two options are technically unfavorable,more » also they are conventional Waste Management Technologies (WMT) which provide short-term remedial solution. In contrast, Produced Water Re-Injection (PWRI) is an Environmental Control Technology (ECT) which minimize the environmental impact through process improvements. A state -of-the-art re-injection process was utilized using chemical treatment, gas liberation, settling, filtration and injection. This process represents a combination of two (ECT) methods: Reuse (for water flooding) and Recycling (when brine is redisposed underground). This process reduce the overall volumes of produced water to be disposed, increase the oil reserves, reservoir pressure and oil production and converse the underground water reserve.« less
Research on crude oil storage and transportation based on optimization algorithm
NASA Astrophysics Data System (ADS)
Yuan, Xuhua
2018-04-01
At present, the optimization theory and method have been widely used in the optimization scheduling and optimal operation scheme of complex production systems. Based on C++Builder 6 program development platform, the theoretical research results are implemented by computer. The simulation and intelligent decision system of crude oil storage and transportation inventory scheduling are designed. The system includes modules of project management, data management, graphics processing, simulation of oil depot operation scheme. It can realize the optimization of the scheduling scheme of crude oil storage and transportation system. A multi-point temperature measuring system for monitoring the temperature field of floating roof oil storage tank is developed. The results show that by optimizing operating parameters such as tank operating mode and temperature, the total transportation scheduling costs of the storage and transportation system can be reduced by 9.1%. Therefore, this method can realize safe and stable operation of crude oil storage and transportation system.
Tian, Xiaofeng; Cheng, Linsong; Cao, Renyi; Zhang, Miaoyi; Guo, Qiang; Wang, Yimin; Zhang, Jian; Cui, Yu
2015-07-01
Carbon -di-oxide (CO2) is regarded as the most important greenhouse gas to accelerate climate change and ocean acidification. The Chinese government is seeking methods to reduce anthropogenic CO2 gas emission. CO2 capture and geological storage is one of the main methods. In addition, injecting CO2 is also an effective method to replenish formation energy in developing tight oil reservoirs. However, exiting methods to estimate CO2 storage capacity are all based on the material balance theory. This was absolutely correct for normal reservoirs. However, as natural fractures widely exist in tight oil reservoirs and majority of them are vertical ones, tight oil reservoirs are not close. Therefore, material balance theory is not adaptive. In the present study, a new method to calculate CO2 storage capacity is presented. The CO2 effective storage capacity, in this new method, consisted of free CO2, CO2 dissolved in oil and CO2 dissolved in water. Case studies of tight oil reservoir from Ordos Basin was conducted and it was found that due to far lower viscosity of CO2 and larger solubility in oil, CO2 could flow in tight oil reservoirs more easily. As a result, injecting CO2 in tight oil reservoirs could obviously enhance sweep efficiency by 24.5% and oil recovery efficiency by 7.5%. CO2 effective storage capacity of Chang 7 tight oil reservoir in Longdong area was 1.88 x 10(7) t. The Chang 7 tight oil reservoir in Ordos Basin was estimated to be 6.38 x 10(11) t. As tight oil reservoirs were widely distributed in Songliao Basin, Sichuan Basin and so on, geological storage capacity of CO2 in China is potential.
2. PAINT AND OIL STORAGE SHED, FRONT AND RIGHT SIDES, ...
2. PAINT AND OIL STORAGE SHED, FRONT AND RIGHT SIDES, LOOKING SOUTH. - NIKE Missile Base SL-40, Paint & Oil Storage Shed, North end of base, northwest of Mess Hall & south of Basketball Court, Hecker, Monroe County, IL
Do Shale Pore Throats Have a Threshold Diameter for Oil Storage?
Zou, Caineng; Jin, Xu; Zhu, Rukai; Gong, Guangming; Sun, Liang; Dai, Jinxing; Meng, Depeng; Wang, Xiaoqi; Li, Jianming; Wu, Songtao; Liu, Xiaodan; Wu, Juntao; Jiang, Lei
2015-01-01
In this work, a nanoporous template with a controllable channel diameter was used to simulate the oil storage ability of shale pore throats. On the basis of the wetting behaviours at the nanoscale solid-liquid interfaces, the seepage of oil in nano-channels of different diameters was examined to accurately and systematically determine the effect of the pore diameter on the oil storage capacity. The results indicated that the lower threshold for oil storage was a pore throat of 20 nm, under certain conditions. This proposed pore size threshold provides novel, evidence-based criteria for estimating the geological reserves, recoverable reserves and economically recoverable reserves of shale oil. This new understanding of shale oil processes could revolutionize the related industries. PMID:26314637
Do Shale Pore Throats Have a Threshold Diameter for Oil Storage?
Zou, Caineng; Jin, Xu; Zhu, Rukai; Gong, Guangming; Sun, Liang; Dai, Jinxing; Meng, Depeng; Wang, Xiaoqi; Li, Jianming; Wu, Songtao; Liu, Xiaodan; Wu, Juntao; Jiang, Lei
2015-08-28
In this work, a nanoporous template with a controllable channel diameter was used to simulate the oil storage ability of shale pore throats. On the basis of the wetting behaviours at the nanoscale solid-liquid interfaces, the seepage of oil in nano-channels of different diameters was examined to accurately and systematically determine the effect of the pore diameter on the oil storage capacity. The results indicated that the lower threshold for oil storage was a pore throat of 20 nm, under certain conditions. This proposed pore size threshold provides novel, evidence-based criteria for estimating the geological reserves, recoverable reserves and economically recoverable reserves of shale oil. This new understanding of shale oil processes could revolutionize the related industries.
Schinus molle: a new source of natural fungitoxicant.
Dikshit, A; Naqvi, A A; Husain, A
1986-05-01
The oil of Schinus molle exhibited the maximum fungitoxic activity during the screening of some essential oils against some common storage and animal pathogenic fungi. It showed absolute toxicity against animal pathogens and mild activity against storage fungi. The effective concentrations of the oil varied from 200 to 900 ppm. The toxicity of the oil persisted up to 80 degrees C and 90 days of storage but declined when autoclaved. It withstood heavy inoculum density. The oil exhibited a narrow range of activity and was found to be more effective than Multifungin, an antifungal drug. The oil was characterized by its various physicochemical properties. It was found to comprise 50 constituents. It appeared that some changes in the oil constituents during storage affected its fungitoxic potency.
Carbon Capture and Sequestration (CCS)
2009-06-19
tons of CO2 underground each year to help recover oil and gas resources (enhanced oil recovery , or EOR).1 Also, potentially large amounts of CO2 ... CO2 will be used for enhanced gas recovery at a nearby natural gas field. See http://www.vattenfall.com/www/co2_en/ co2_en/Gemeinsame_Inhalte...for enhanced oil recovery (EOR).18 Transporting CO2 in pipelines is similar to transporting petroleum products like natural gas and oil; it requires
Method of rubblization for in-situ oil shale processing
NASA Technical Reports Server (NTRS)
Yang, Lien C. (Inventor)
1985-01-01
A method that produces a uniformly rubblized oil shale bed of desirable porosity for underground, in-situ heat extraction of oil. Rubblization is the generation of rubble of various sized fragments. The method uses explosive loadings lying at different levels in adjacent holes and detonation of the explosives at different levels in sequence to achieve the fracturing and the subsequent expansion of the fractured oil shale into excavated rooms both above and below the hole pattern.
Code of Federal Regulations, 2014 CFR
2014-07-01
... percent of the maximum capacity of the fuel storage system; and (7) Provided with a competent concrete... any buildup pressure before heat is applied. (2) Diesel fuel shall not be allowed to enter pipelines...
Code of Federal Regulations, 2013 CFR
2013-07-01
... percent of the maximum capacity of the fuel storage system; and (7) Provided with a competent concrete... any buildup pressure before heat is applied. (2) Diesel fuel shall not be allowed to enter pipelines...
Code of Federal Regulations, 2011 CFR
2011-07-01
... percent of the maximum capacity of the fuel storage system; and (7) Provided with a competent concrete... any buildup pressure before heat is applied. (2) Diesel fuel shall not be allowed to enter pipelines...
Code of Federal Regulations, 2012 CFR
2012-07-01
... percent of the maximum capacity of the fuel storage system; and (7) Provided with a competent concrete... any buildup pressure before heat is applied. (2) Diesel fuel shall not be allowed to enter pipelines...
NASA Astrophysics Data System (ADS)
Dhote, Yogesh; Thombre, Shashikant
2016-10-01
This paper presents the thermal performance of the proposed double flow natural convection solar air heater with in-built liquid (oil) sensible heat storage. Unused engine oil was used as thermal energy storage medium due to its good heat retaining capacity even at high temperatures without evaporation. The performance evaluation was carried out for a day of the month March for the climatic conditions of Nagpur (India). A self reliant computational model was developed using computational tool as C++. The program developed was self reliant and compute the performance parameters for any day of the year and would be used for major cities in India. The effect of change in storage oil quantity and the inclination (tilt angle) on the overall efficiency of the solar air heater was studied. The performance was tested initially at different storage oil quantities as 25, 50, 75 and 100 l for a plate spacing of 0.04 m with an inclination of 36o. It has been found that the solar air heater gives the best performance at a storage oil quantity of 50 l. The performance of the proposed solar air heater is further tested for various combinations of storage oil quantity (50, 75 and 100 l) and the inclination (0o, 15o, 30o, 45o, 60o, 75o, 90o). It has been found that the proposed solar air heater with in-built oil storage shows its best performance for the combination of 50 l storage oil quantity and 60o inclination. Finally the results of the parametric study was also presented in the form of graphs carried out for a fixed storage oil quantity of 25 l, plate spacing of 0.03 m and at an inclination of 36o to study the behaviour of various heat transfer and fluid flow parameters of the solar air heater.
Costs of Storing and Transporting Hydrogen
DOE Office of Scientific and Technical Information (OSTI.GOV)
Amos, W. A.
An analysis was performed to estimate the costs associated with storing and transporting hydrogen. These costs can be added to a hydrogen production cost to determine the total delivered cost of hydrogen. Storage methods analyzed included compressed gas, liquid hydrogen, metal hydride, and underground storage. Major capital and operating costs were considered over a range of production rates and storage times.
Code of Federal Regulations, 2010 CFR
2010-07-01
... and hydrocarbon storage wells authorized by rule. 147.1154 Section 147.1154 Protection of Environment... UNDERGROUND INJECTION CONTROL PROGRAMS Michigan § 147.1154 Existing Class II enhanced recovery and hydrocarbon... determines that the owner or operator of an existing enhanced recovery or hydrocarbon storage will may not be...
Code of Federal Regulations, 2011 CFR
2011-07-01
... and hydrocarbon storage wells authorized by rule. 147.1454 Section 147.1454 Protection of Environment... UNDERGROUND INJECTION CONTROL PROGRAMS Nevada § 147.1454 Existing Class II enhanced recovery and hydrocarbon... determines that the owner or operator of an existing enhanced recovery or hydrocarbon storage well may not be...
Code of Federal Regulations, 2010 CFR
2010-07-01
... and hydrocarbon storage wells authorized by rule. 147.1454 Section 147.1454 Protection of Environment... UNDERGROUND INJECTION CONTROL PROGRAMS Nevada § 147.1454 Existing Class II enhanced recovery and hydrocarbon... determines that the owner or operator of an existing enhanced recovery or hydrocarbon storage well may not be...
Code of Federal Regulations, 2010 CFR
2010-07-01
... and hydrocarbon storage wells authorized by rule. 147.1654 Section 147.1654 Protection of Environment... UNDERGROUND INJECTION CONTROL PROGRAMS New York § 147.1654 Existing Class II enhanced recovery and hydrocarbon... the owner or operator of an existing enhanced recovery or hydrocarbon storage well may not be in...
Code of Federal Regulations, 2011 CFR
2011-07-01
... and hydrocarbon storage wells authorized by rule. 147.1154 Section 147.1154 Protection of Environment... UNDERGROUND INJECTION CONTROL PROGRAMS Michigan § 147.1154 Existing Class II enhanced recovery and hydrocarbon... determines that the owner or operator of an existing enhanced recovery or hydrocarbon storage will may not be...
Code of Federal Regulations, 2011 CFR
2011-07-01
... and hydrocarbon storage wells authorized by rule. 147.1654 Section 147.1654 Protection of Environment... UNDERGROUND INJECTION CONTROL PROGRAMS New York § 147.1654 Existing Class II enhanced recovery and hydrocarbon... the owner or operator of an existing enhanced recovery or hydrocarbon storage well may not be in...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
The Adrian Municipal Well Field is listed by the U.S. Environmental Protection Agency (EPA) on the National Priorities List (NPL). In September 1983, 1,2-dichloroethane (1,2-DCA), a volatile organic compound (VOC), was detected in City Wells 3 and 4. Subsequent sampling in January 1984 indicated increased levels of VOC contamination in Wells 3 and 4. In January 1984, the Minnesota Department of Health (MDH) issued a health advisory recommending that Wells 3 and 4 not be used as a source of drinking water. Underground storage tanks (USTs) containing gasoline and fuel oil have been identified as the source of contaminants tomore » ground water. The primary potential route of human exposure to the contaminants at the Adrian site is through the use of contaminated ground water (i.e., ingestion, inhalation, dermal contact, and ingestion of garden vegetables contaminated via watering). The proximity of all the city wells to the gasoline and fuel oil contaminant plume, the hydrologic characteristics of the meltwater channel from which the city wells draw their water, and seasonal variations in direction and rate of ground-water flow indicate a need for continued caution in the use of all city wells.« less
Roasting pumpkin seeds and changes in the composition and oxidative stability of cold-pressed oils.
Raczyk, Marianna; Siger, Aleksander; Radziejewska-Kubzdela, Elżbieta; Ratusz, Katarzyna; Rudzińska, Magdalena
2017-01-01
Pumpkin seed oil is valuable oil for its distinctive taste and aroma, as well as supposed health- promoting properties. The aim of this study was to investigate how roasting pumpkin seeds influences the physicochemical properties of cold-pressed oils. The fatty acid composition, content of phytosterols, carotenoids and tocopherols, oxidative stability and colour were determined in oils after cold pressing and storage for 3 months using GC-FID, GCxGC-ToFMS, HPLC, Rancimat and spectrophotometric methods. The results of this study indicate that the seed-roasting and storage process have no effect on the fatty acid composition of pumpkin seed oils, but does affect phytosterols and tocopherols. The carotenoid content decreased after storage. The colour of the roasted oil was darker and changed significantly during storage. Pumpkin oil obtained from roasted seeds shows better physicochemical properties and oxidative stability than oil from unroasted seeds.
OVERVIEW OF CENTRAL HEATING PLANT, WITH OIL STORAGE ON LEFT, ...
OVERVIEW OF CENTRAL HEATING PLANT, WITH OIL STORAGE ON LEFT, BOILER BUILDING ON RIGHT, SOUTH AND EAST ELEVATIONS, CAMERA FACING NORTH. - New Haven Rail Yard, Central Steam Plant and Oil Storage, Vicinity of Union Avenue, New Haven, New Haven County, CT
30 CFR 57.6160 - Main facilities.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Explosives Storage... facilities will not prevent escape from the mine, or cause detonation of the contents of another storage...
Schinus molle: a new source of natural fungitoxicant.
Dikshit, A; Naqvi, A A; Husain, A
1986-01-01
The oil of Schinus molle exhibited the maximum fungitoxic activity during the screening of some essential oils against some common storage and animal pathogenic fungi. It showed absolute toxicity against animal pathogens and mild activity against storage fungi. The effective concentrations of the oil varied from 200 to 900 ppm. The toxicity of the oil persisted up to 80 degrees C and 90 days of storage but declined when autoclaved. It withstood heavy inoculum density. The oil exhibited a narrow range of activity and was found to be more effective than Multifungin, an antifungal drug. The oil was characterized by its various physicochemical properties. It was found to comprise 50 constituents. It appeared that some changes in the oil constituents during storage affected its fungitoxic potency. PMID:3729389
DOE Office of Scientific and Technical Information (OSTI.GOV)
Neal, J.T.; Myers, R.E.
1995-01-27
A sinkhole was first observed in May 1992 over the edge of the two-level former salt mine that was converted for oil storage by the US Strategic Petroleum Reserve (SPR). Diagnostic studies that included geophysical, geochemical, drilling, and hydrological methods suggest a direct connection exists between the surface collapse area and the underground mine as shown by correlative measurements of sediment slump rates and brine influx into the mine. The dissolution of salt below the sinkhole that initiated the leak into the mine was likely caused by several confluent geologic processes, and exacerbated by mining-induced stresses that created fractures whichmore » served as hydrologic flowpaths. Modeling studies of mine stresses show that years may be required before tensional cracking begins to occur, but once begun can continue to develop, and relieve the stress in that specific regime. The crack regime creates the avenue for incursion of groundwater, very slowly initially, but gradually enlarging as undersaturated groundwater dissolves salt on the sides of the crack. Mitigation measures include increasing the mine pressurization, slowing the dissolution by injecting brine into the sinkhole throat, and freeze grouting to restrict hydrologic flowpaths.« less
NASA Astrophysics Data System (ADS)
Hagemann, B.; Feldmann, F.; Panfilov, M.; Ganzer, L.
2015-12-01
The change from fossil to renewable energy sources is demanding an increasing amount of storage capacities for electrical energy. A promising technological solution is the storage of hydrogen in the subsurface. Hydrogen can be produced by electrolysis using excessive electrical energy and subsequently converted back into electricity by fuel cells or engine generators. The development of this technology starts with adding small amounts of hydrogen to the high pressure natural gas grid and continues with the creation of pure underground hydrogen storages. The feasibility of hydrogen storage in depleted gas reservoirs is investigated in the lighthouse project H2STORE financed by the German Ministry for Education and Research. The joint research project has project members from the University of Jena, the Clausthal University of Technology, the GFZ Potsdam and the French National Center for Scientic Research in Nancy. The six sub projects are based on laboratory experiments, numerical simulations and analytical work which cover the investigation of mineralogical, geochemical, physio-chemical, sedimentological, microbiological and gas mixing processes in reservoir and cap rocks. The focus in this presentation is on the numerical modeling of underground hydrogen storage. A mathematical model was developed which describes the involved coupled hydrodynamic and microbiological effects. Thereby, the bio-chemical reaction rates depend on the kinetics of microbial growth which is induced by the injection of hydrogen. The model has been numerically implemented on the basis of the open source code DuMuX. A field case study based on a real German gas reservoir was performed to investigate the mixing of hydrogen with residual gases and to discover the consequences of bio-chemical reactions.
Oliveira, Tuane S DE; Bombo, Aline B; Oliveira, Adriana S S DE; Garcia, Vera L; Appezzato-DA-Glória, Beatriz
2016-01-01
Aldama arenaria and A. robusta are morphologically similar aromatic species that have seasonal development. The yield and chemical composition of essential oils from aerial and underground vegetative organs of these species were compared to verify the production of volatile metabolites in flowering and dormant phases of development and to identify if there are unique compounds for either species. The major compound in the essential oils from A. arenaria leaves was palustrol (16.22%) and for aerial stems was limonene (15.3%), whereas limonene (11.16%) and α-pinene (19.64%) were the major compounds for leaves and aerial stems from A. robusta, respectively. The major compound for the underground organs was α-pinene, in both species and phenological stages. High amounts of diterpenes were found especially for A. arenaria essential oils. Each analyzed species presented unique compounds, which can provide a characteristic chemical profile for both species helping to solve their taxonomic problems. This study characterized for the first time the yield and essential oil composition of A. arenaria and A. robusta, which have medicinal potential, and some of the compounds in their essential oils are unique to each one and may be useful in helping the correct identification of them.
Bryce, David A; Shao, Hongbo; Cantrell, Kirk J; Thompson, Christopher J
2016-06-07
CO2 injected into depleted oil or gas reservoirs for long-term storage has the potential to mobilize organic compounds and distribute them between sediments and reservoir brines. Understanding this process is important when considering health and environmental risks, but little quantitative data currently exists on the partitioning of organics between supercritical CO2 and water. In this work, a high-pressure, in situ measurement capability was developed to assess the distribution of organics between CO2 and water at conditions relevant to deep underground storage of CO2. The apparatus consists of a titanium reactor with quartz windows, near-infrared and UV spectroscopic detectors, and switching valves that facilitate quantitative injection of organic reagents into the pressurized reactor. To demonstrate the utility of the system, partitioning coefficients were determined for benzene in water/supercritical CO2 over the range 35-65 °C and approximately 25-150 bar. Density changes in the CO2 phase with increasing pressure were shown to have dramatic impacts on benzene's partitioning behavior. Our partitioning coefficients were approximately 5-15 times lower than values previously determined by ex situ techniques that are prone to sampling losses. The in situ methodology reported here could be applied to quantify the distribution behavior of a wide range of organic compounds that may be present in geologic CO2 storage scenarios.
Bonte, Anja; Schweiger, Rabea; Pons, Caroline; Wagner, Claudia; Brühl, Ludger; Matthäus, Bertrand; Müller, Caroline
2017-12-20
Virgin rapeseed (Brassica napus) oil is a valuable niche product, if delivered with a high quality. In this study, the effects of moist storage of B. napus seeds for 1 to 4 days on the seed metabolome and the chemo-sensory properties of the produced oils were determined. The concentrations of several primary metabolites, including monosaccharides and amino acids, rapidly increased in the seeds, probably indicating the breakdown of storage compounds to support seed germination. Seed concentrations of indole glucosinolates increased with a slight time offset suggesting that amino acids may be used to modify secondary metabolism. The volatile profiles of the oils were pronouncedly influenced by moist seed storage, with the sensory quality of the oils decreasing. This study provides a direct time-resolved link between seed metabolism under moist conditions and the quality of the resulting oils, thereby emphasizing the crucial role of dry seed storage in ensuring high oil quality.
30 CFR 57.4431 - Surface storage restrictions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Surface storage restrictions. 57.4431 Section 57.4431 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire...
M. Kat Anderson; Frank K. Lake
2016-01-01
California supported a great diversity of plants with edible underground storage organs available to Indian tribes. Together, plant foods, fish and meat made up an indigenous diet that was well-rounded, diverse, and relatively secure. The edible underground parts possessed by these plants are classified as bulbs, corms, taproots, tubers and rhizomes, and when...
Dale, R.H.; Weeks, John B.
1978-01-01
The U.S. Bureau of Mines plans to develop an underground oil-shale research facility near the center of Piceance Creek basin in Colorado. The oil-shale zone, which is to be penetrated by a shaft, is overlain by 1,400 feet of sedimentary rocks, primarily sandstone and marlstone, consisting of two aquifers separated by a confining layer. Three test holes were drilled by the U.S. Bureau of Mines to obtain samples of the oil shale, and to test the hydraulic properties of the two aquifers. The data collected during construction of the test holes were used to update an existing ground-water-flow computer model. The model was used to estimate the maximum amount of water that would have to be pumped to dewater the shaft during its construction. It is estimated that it would be necessary to pump as much as 3,080 gallons per minute to keep the shaft dry. Disposal of waste water and rock are the principal hydrologic problems associated with constructing the shaft. (Woodard-USGS)
A role for caleosin in degradation of oil-body storage lipid during seed germination.
Poxleitner, Marianne; Rogers, Sally W; Lacey Samuels, A; Browse, John; Rogers, John C
2006-09-01
Caleosin is a Ca(2+)-binding oil-body surface protein. To assess its role in the degradation of oil-bodies, two independent insertion mutants lacking caleosin were studied. Both mutants demonstrated significant delay of breakdown of the 20:1 storage lipid at 48 and 60 h of germination. Additionally, although germination rates for seeds were not affected by the mutations, mutant seedlings grew more slowly than wild type when measured at 48 h of germination, a defect that was corrected with continued growth for 72 and 96 h in the light. After 48 h of germination, wild-type central vacuoles had smooth contours and demonstrated internalization of oil bodies and of membrane containing alpha- and delta-tonoplast intrinsic proteins (TIPs), markers for protein storage vacuoles. In contrast, mutant central vacuoles had distorted limiting membranes displaying domains with clumps of the two TIPs, and they contained fewer oil bodies. Thus, during germination caleosin plays a role in the degradation of storage lipid in oil bodies. Its role involves both the normal modification of storage vacuole membrane and the interaction of oil bodies with vacuoles. The results indicate that interaction of oil bodies with vacuoles is one mechanism that contributes to the degradation of storage lipid.
NASA Astrophysics Data System (ADS)
Marandi, Andres; Karro, Enn; Polikarpus, Maile; Jõeleht, Argo; Kohv, Marko; Hang, Tiit; Hiiemaa, Helen
2013-11-01
The water balance of wetlands plays an integral role in their function. Developments adjacent to wetlands can affect their water balance through impacts on groundwater flow and increased discharge in the area, and they can cause lowering of the wetland water table. A 430 km2 area was selected for groundwater modelling to asses the effect of underground mining on the water balance of wetlands in north-eastern Estonia. A nature conservation area (encompassing Selisoo bog) is within 3 km of an underground oil-shale mine. Two future mining scenarios with different areal extents of mining were modeled and compared to the present situation. Results show that the vertical hydraulic conductivity of the subsurface is of critical importance to potential wetland dewatering as a result of mining. Significant impact on the Selisoo bog water balance will be caused by the approaching mine but there will be only minor additional impacts from mining directly below the bog. The major impact will arise before that stage, when the underground mine extension reaches the border of the nature conservation area; since the restriction of activities in this area relates to the ground surface, the conservation area’s border is not sufficiently protective in relation to underground development.
ENZYMES FOR ENHANCING BIOREMEDIATION OF PETROLEUM- CONTAMINATED SOILS: A BRIEF REVIEW
During the 1950s and 1960s, hundreds of thousands of underground storage tanks (and above-ground storage tanks) containing petroleum products and hazardous chemicals were installed. Many of these tanks either have been abandoned or have exceeded their useful lives and are leakin...
30 CFR 57.4401 - Storage tank foundations.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Storage tank foundations. 57.4401 Section 57.4401 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention...
30 CFR 57.4601 - Oxygen cylinder storage.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Oxygen cylinder storage. 57.4601 Section 57.4601 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention...
A Historical Evaluation of the U15 Complex, Nevada National Security Site, Nye County, Nevada
DOE Office of Scientific and Technical Information (OSTI.GOV)
Drollinger, Harold; Holz, Barbara A.; Bullard, Thomas F.
2014-01-01
This report presents a historical evaluation of the U15 Complex on the Nevada National Security Site (NNSS) in southern Nevada. The work was conducted by the Desert Research Institute at the request of the U.S. Department of Energy, National Nuclear Security Administration Nevada Field Office and the U.S. Department of Defense, Defense Threat Reduction Agency. Three underground nuclear tests and two underground nuclear fuel storage experiments were conducted at the complex. The nuclear tests were Hard Hat in 1962, Tiny Tot in 1965, and Pile Driver in 1966. The Hard Hat and Pile Driver nuclear tests involved different types ofmore » experiment sections in test drifts at various distances from the explosion in order to determine which sections could best survive in order to design underground command centers. The Tiny Tot nuclear test involved an underground cavity in which the nuclear test was executed. It also provided data in designing underground structures and facilities to withstand a nuclear attack. The underground nuclear fuel storage experiments were Heater Test 1 from 1977 to 1978 and Spent Fuel Test - Climax from 1978 to 1985. Heater Test 1 was used to design the later Spent Fuel Test - Climax experiment. The latter experiment was a model of a larger underground storage facility and primarily involved recording the conditions of the spent fuel and the surrounding granite medium. Fieldwork was performed intermittently in the summers of 2011 and 2013, totaling 17 days. Access to the underground tunnel complex is sealed and unavailable. Restricted to the surface, four buildings, four structures, and 92 features associated with nuclear testing and fuel storage experiment activities at the U15 Complex have been recorded. Most of these are along the west side of the complex and next to the primary access road and are characteristic of an industrial mining site, albeit one with scientific interests. The geomorphological fieldwork was conducted over three days in the summer of 2011. It was discovered that major modifications to the terrain have resulted from four principal activities. These are road construction and maintenance, mining activities related to development of the tunnel complex, site preparation for activities related to the tests and experiments, and construction of drill pads and retention ponds. Six large trenches for exploring across the Boundary geologic fault are also present. The U15 Complex, designated historic district 143 and site 26NY15177, is eligible to the National Register of Historic Places under Criteria A, C, and D of 36 CFR Part 60.4. As a historic district and archaeological site eligible to the National Register of Historic Places, the Desert Research Institute recommends that the area defined for the U15 Complex, historic district 143 and site 26NY15117, be left in place in its current condition. The U15 Complex should also be included in the NNSS cultural resources monitoring program and monitored for disturbances or alterations.« less
A Historical Evaluation of the U15 Complex, Nevada National Security Site, Nye County, Nevada
DOE Office of Scientific and Technical Information (OSTI.GOV)
Drollinger, Harold; Holz, Barbara A.; Bullard, Thomas F.
2014-01-09
This report presents a historical evaluation of the U15 Complex on the Nevada National Security Site (NNSS) in southern Nevada. The work was conducted by the Desert Research Institute at the request of the U.S. Department of Energy, National Nuclear Security Administration Nevada Field Office and the U.S. Department of Defense, Defense Threat Reduction Agency. Three underground nuclear tests and two underground nuclear fuel storage experiments were conducted at the complex. The nuclear tests were Hard Hat in 1962, Tiny Tot in 1965, and Pile Driver in 1966. The Hard Hat and Pile Driver nuclear tests involved different types ofmore » experiment sections in test drifts at various distances from the explosion in order to determine which sections could best survive in order to design underground command centers. The Tiny Tot nuclear test involved an underground cavity in which the nuclear test was executed. It also provided data in designing underground structures and facilities to withstand a nuclear attack. The underground nuclear fuel storage experiments were Heater Test 1 from 1977 to 1978 and Spent Fuel Test - Climax from 1978 to 1985. Heater Test 1 was used to design the later Spent Fuel Test - Climax experiment. The latter experiment was a model of a larger underground storage facility and primarily involved recording the conditions of the spent fuel and the surrounding granite medium. Fieldwork was performed intermittently in the summers of 2011 and 2013, totaling 17 days. Access to the underground tunnel complex is sealed and unavailable. Restricted to the surface, four buildings, four structures, and 92 features associated with nuclear testing and fuel storage experiment activities at the U15 Complex have been recorded. Most of these are along the west side of the complex and next to the primary access road and are characteristic of an industrial mining site, albeit one with scientific interests. The geomorphological fieldwork was conducted over three days in the summer of 2011. It was discovered that major modifications to the terrain have resulted from four principal activities. These are road construction and maintenance, mining activities related to development of the tunnel complex, site preparation for activities related to the tests and experiments, and construction of drill pads and retention ponds. Six large trenches for exploring across the Boundary geologic fault are also present. The U15 Complex, designated historic district 143 and site 26NY15177, is eligible to the National Register of Historic Places under Criteria A, C, and D of 36 CFR Part 60.4. As a historic district and archaeological site eligible to the National Register of Historic Places, the Desert Research Institute recommends that the area defined for the U15 Complex, historic district 143 and site 26NY15117, be left in place in its current condition. The U15 Complex should also be included in the NNSS cultural resources monitoring program and monitored for disturbances or alterations.« less
Yang, Ying; Zhao, Chengying; Tian, Guifang; Lu, Chang; Zhao, Shaojie; Bao, Yuming; McClements, David Julian; Xiao, Hang; Zheng, Jinkai
2017-09-06
Citrus oils are used as good carrier oil for emulsion fabrication due to their special flavor and various health-promoting functions. In this study, the effects of preheating temperature (30, 40, 50, 60, and 70 °C) and storage temperature (4, 25, and 37 °C) on aroma profiles and physical properties of three citrus-oil (i.e., mandarin, sweet orange, and bergamot oils) emulsions were systematically investigated for the first time. The results demonstrated the significant impact of temperature on aroma profile and physical properties. The abundance of d-limonene was found to be the main factor determining the aroma of the three citrus-oil emulsions at different preheating and storage temperatures, while β-linalool and linalyl acetate were important for the aroma of bergamot oil emulsion. Preheating temperature showed a profound impact on the aroma of citrus-oil emulsions, and the aroma of different citrus oil emulsions showed different sensitivity to preheating temperature. Storage temperature was also able to alter the properties of citrus oil emulsions. The higher was the storage temperature, the more alteration of aroma and more instability of the emulsions there was, which could be attributed to the alteration of the oil components and the properties of emulsions. Among all three emulsions, bergamot-oil emulsion was the most stable and exhibited the most potent ability to preserve the aroma against high temperature. Our results would facilitate the application of citrus-oil emulsions in functional foods and beverages.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-29
... reservoir; (5) an underground powerhouse with approximate dimensions of 250-feet-long by 75-feet-wide by 100... project would be a pumped storage project and consist of the following: (1) A new 30-foot-high earthen dam with a crest length of 3,881 feet; (2) an upper reservoir having a total storage capacity of 5,399 acre...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-29
... reservoir; (5) an underground powerhouse with approximate dimensions of 250-feet-long by 75-feet-wide by 100... project would be a pumped storage project and consist of the following: (1) A new 30-foot-high earthen dam with a crest length of 3,359 feet; (2) an upper reservoir having a total storage capacity of 4,831 acre...
Underground gas storage in the Leyden lignite mine
DOE Office of Scientific and Technical Information (OSTI.GOV)
Meddles, R.M.
1978-01-01
Underground gas storage in the Leyden lignite mine by Public Service Co. of Colorado was preceded by careful studies of mine records with respect to geologic conditions and investigation of the gas-sealing potential of the rocks surrounding the cavern. The water level in shaft No. 3 in Sept. 1958 was about 100 ft above the coal seam at that point. Wells were drilled into the mine up-dip (east) of the structurally highest point that a mine shaft intersected the coal seams, and gas was injected into the mine, using the mine water as a seal. At least the up-dip partmore » of the mine was gas-tight, and tests were expanded to the rest of the mine, which also proved to be gas-tight. All that remained to complete the preparation of the mine for permanent gas storage was sealing of the old mine shafts.« less
Migration of carbon dioxide included micro-nano bubble water in porous media and its monitoring
NASA Astrophysics Data System (ADS)
Takemura, T.; Hamamoto, S.; Suzuki, K.; Koichi, O.
2017-12-01
The distributed CO2 storage is the small scale storage and its located near the emission areas. In the distributed CO2 storage, the CO2 is neutralized by sediment and underground water in the subsurface region (300-500m depth). Carbon dioxide (CO2) included micro-nano bubbles is one approach in neutralizing CO2 and sediments by increasing CO2 volume per unit volume of water and accelerating the chemical reaction. In order to design underground treatment for CO2 gas in the subsurface, it is required to elucidate the behavior of CO2 included micro-nano bubbles in the water. In this study, we carried out laboratory experiment using the soil tank, and measure the amount of leakage of CO2 gas at the surface. In addition, the process of migration of carbon dioxide included micro-nano bubble was monitored by the nondestructive method, wave velocity and resistivity.
76 FR 76684 - Idaho: Tentative Approval of State Underground Storage Tank Program
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-08
.... Skyline, Suite B, Idaho Falls, ID 83402 from 10 a.m. to 12 p.m. and 1 p.m. to 4 p.m.; and 6. IDEQ Lewiston... ENVIRONMENTAL PROTECTION AGENCY 40 CFR Part 281 [EPA-R10-UST-2011-0896; FRL-9502-6] Idaho...). ACTION: Proposed rule. SUMMARY: The State of Idaho has applied for final approval of its Underground...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-23
... facilities 486210 Pipeline transportation of natural gas. Petroleum and Natural Gas Systems. 221210 Natural... and Budget PHMSA Pipeline and Hazardous Material Safety Administration QA/QC quality assurance/quality... distribution pipelines, but also into liquefied natural gas storage or into underground storage. We are...
Learn about how EPA Region 9, Hawaii’s Department of Health, U.S. Navy, and Defense Logistics Agency are working tprotect human health and the environment at the Red Hill Bulk Fuel Storage Facility in Hawaii.
30 CFR 77.209 - Surge and storage piles.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES Surface... a reclaiming area or in any other area at or near a surge or storage pile where the reclaiming...
REGULATING THE ULTIMATE SINK: MANAGING THE RISKS OF GEOLOGIC CO2 STORAGE
The paper addresses the issue of geologic storage (GS) of carbon dioxide (CO2) and discusses the risks and regulatory history of deep underground waste injection on the U.S. mainland and surrounding continental shelf. The treatment focuses on the technical and regulatory aspects ...
Tan, Choon-Hui; Ariffin, Abdul A; Ghazali, Hasanah M; Tan, Chin-Ping; Kuntom, Ainie; Choo, Adrian Cheng-Yong
2017-06-01
This article reports on the changes of oxidation indices and minor components of low free fatty acid (FFA) and freshly extracted crude palm oils after storage at ambient (28 ± 1 C) and 60 C for 77 days. The changes in peroxide value (PV), FFA, extinction coefficient at 233 and 269 nm ( K 233 and K 269 ), bleachability index (DOBI), carotene and vitamin E contents were monitored. PV, FFA, K 233 and K 269 of both oil samples increased as storage progressed while the values of carotene and vitamin E contents decreased. At the end of storage period at 60 °C, the carotene content of low FFA crude palm oil was 4.24 ppm. The storage conditions used led to the loss of entire vitamin E fractions of both oil samples as well as a reduction in DOBI values except for freshly extracted crude palm oil stored at ambient temperature.
1987-10-29
nonferrous ores in quarries and underground; Installations for desulfurization , cleaning, and dry- ing of gas , turbocompressors for methane gas ; Mining...Products Exportation Bucharest Minis- "Indus- try of trial- Foreign Drilling installations and equipment for oil and gas ; export- Trade...equipment; try of Refineries, complex installations, parts, and equip- the ment for the oil- and gas -refining industry; Heavy Factories, complex
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-17
..., East Cheyenne planned to do enhanced oil recovery (EOR) of petroleum reserves remaining in the storage... primarily involves redeveloping a number of existing oil production wells in the West Peetz and Lewis Creek... of construction and operation of a natural gas storage facility in two nearly depleted oil production...
Stability evaluation of quality parameters for palm oil products at low temperature storage.
Ramli, Nur Aainaa Syahirah; Mohd Noor, Mohd Azmil; Musa, Hajar; Ghazali, Razmah
2018-07-01
Palm oil is one of the major oils and fats produced and traded worldwide. The value of palm oil products is mainly influenced by their quality. According to ISO 17025:2005, accredited laboratories require a quality control procedure with respect to monitoring the validity of tests for determination of quality parameters. This includes the regular use of internal quality control using secondary reference materials. Unfortunately, palm oil reference materials are not currently available. To establish internal quality control samples, the stability of quality parameters needs to be evaluated. In the present study, the stability of quality parameters for palm oil products was examined over 10 months at low temperature storage (6 ± 2 °C). The palm oil products tested included crude palm oil (CPO); refined, bleached and deodorized (RBD) palm oil (RBDPO); RBD palm olein (RBDPOo); and RBD palm stearin (RBDPS). The quality parameters of the oils [i.e. moisture content, free fatty acid content (FFA), iodine value (IV), fatty acids composition (FAC) and slip melting point (SMP)] were determined prior to and throughout the storage period. The moisture, FFA, IV, FAC and SMP for palm oil products changed significantly (P < 0.05), whereas the moisture content for CPO, IV for RBDPO and RBDPOo, stearic acid composition for CPO and linolenic acid composition for CPO, RBDPO, RBDPOo and RBDPS did not (P > 0.05). The stability study indicated that the quality of the palm oil products was stable within the specified limits throughout the storage period at low temperature. The storage conditions preserved the quality of palm oil products throughout the storage period. These findings qualify the use of the palm oil products CPO, RBDPO, RBDPOo and RBDPS as control samples in the validation of test results. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.
NASA Astrophysics Data System (ADS)
Hastuti, L. T.; Saepudin, E.; Cahyana, A. H.; Rahayu, D. U. C.; Murni, V. W.; Haib, J.
2017-07-01
Clove (Syzygium aromaticum) is native to Indonesia and used as a spice in virtually all of the world's cuisine. Clove bud oil, a yellow liquid, is obtained from distillation of buds. The quality of oil is influenced by origin, post-harvest processing, pre-treatment before distillation, the distillation method, and post-distillation treatment. The objective of this study is to investigate the effect of drying process and prolonged storage on essential oil composition of clove bud from the Tolitoli, Indonesia. To determine the effect of drying, fresh clove bud was dried under sunlight until it reached moisture content 13±1 %. The effect of storage was studied in the oil extracted from clove bud that was stored in laboratory at 25 °C for 4 months. The essential oil of each treatment was obtained by steam distillation and its chemical composition was analyzed by GC/MS. The major components found in fresh and dried clove are as follows: eugenol, eugenyl acetate, and caryophyllene. Percentage of caryophyllene was slightly increase after drying but decrease during storage. While the content of eugenyl acetate decreased during drying and storage, the content of eugenol increased. The drying and storage also affect to the change on minor compounds of essential oil of clove.
Fadda, C; Del Caro, A; Sanguinetti, A M; Urgeghe, P P; Vacca, V; Arca, P P; Piga, A
2012-10-01
Extraction technology has a great effect on quality of olive oils. This paper studied 18 months of storage of two Sardinian extra virgin monovarietal oils obtained with a traditional and with a low oxidative stress technology. Oil samples were subjected to the following chemical analyses: acidity, peroxide value, ultraviolet light absorption K₂₃₂ and K₂₇₀, carotenoids, chlorophylls, tocopherols and total polyphenols. The antioxidant capacity of oils, polyphenol extract and oil extract (remaining after polyphenol extraction) was also determined as radical scavenging activity. The results show that both extraction technologies resulted in minor changes in legal and quality indices during storage, due surely to the high quality of the oils as well as to the very good storage conditions used. Oils obtained with the low oxidative stress technology showed lower peroxide value and acidity and resulted in up to 103% higher total polyphenol content as well as increased radical-scavenging activity, with respect to oils obtained with the traditional technology. Copyright © 2012 Elsevier Ltd. All rights reserved.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-11
... Administrative Rules Regarding the Transfer and Storage of Excess Spearmint Oil AGENCY: Agricultural Marketing... such oil to the Committee or its designees for storage, from November 1 to December 1. This rule also... storage, from November 1 to December 1. This rule also changes the date that the Committee must pool...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
The Adrian Municipal Well Field is listed on the National Priorities List. Adrian is located in Nobles County which is in southwestern Minnesota. In September 1983, 1,2-dichloroethane (1,2-DCA), a volatile organic compound (VOC), was detected in Municipal Wells 3 and 4. Subsequent sampling in January 1984 indicated increased levels of VOC contamination in Wells 3 and 4. In these sampling events, a number of VOCs were detected. Source identification has also focused on a number of underground storage tanks (USTs) used to store gasoline and fuel oil. Twelve contaminants have been identified in ground water from the surficial aquifer. Subsurfacemore » soil contamination has also been detected. A Soil Organic Vapor survey measured both total ionizable hydrocarbons and the gasoline constituents benzene, toluene, and total xylenes at 2-3 feet feet above the water table. Because of the high concentrations of gasoline contaminants in the soil and ground water at the site, there exists the potential for combustion or explosion if gasoline vapors migrate from these media into nearby businesses or homes. Several of the USTs contained or did contain fuel oil. Fuel oil contains semi-volatile constituents (e.g., polynuclear aromatic hydrocarbons, etc.) not found in gasoline. Based on the available information, the site is considered to be of potential public health concern because of the risk to human health caused by the possibility of exposure to hazardous substances via ground water, and potentially surface water, air, and biota.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hedgecock, N.S.
1990-01-01
At the request of 67 Combat Support Group/DEEV the Air Force Occupational and Environmental Health Laboratory conducted a waste-water characterization and hazardous-waste technical assistance survey at Bergstrom AFB (BAFB) from 6-15 Mar 89. The scope of the waste-water survey was to characterize the effluent exiting the base and the effluent from 23 industrial facilities and 10 food-serving facilities. The scope of the hazardous-waste survey was to address hazardous-waste-management practices and explore opportunities for hazardous waste minimization. Specific recommendations from the survey include: (1) Accompany City of Austin personnel during waste-water sampling procedures; (2) Sample at the manhole exiting the mainmore » lift station rather than at the lift station wet well; (3) Split waste-water samples with the City of Austin for comparison of results; (4) Ensure that oil/water separators and grease traps are functioning properly and are cleaned out regularly; (5) Limit the quantity of soaps and solvents discharged down the drain to the sanitary sewer; (6) Establish a waste disposal contract for the removal of wastes in the Petroleum Oils and Lubricants underground storage tanks. (7) Remove, analyze, and properly dispose of oil contaminated soil from accumulation sites. (8) Move indoors or secure, cover, and berm the aluminum sign reconditioning tank at 67 Civil Engineering Squadron Protective Coating. (9) Connect 67 Combat Repair Squadron Test Cell floor drains to the sanitary sewer.« less
40 CFR 52.1931 - Petroleum storage tank controls.
Code of Federal Regulations, 2011 CFR
2011-07-01
... storage at the Sun Oil Company refinery at Duncan, Oklahoma, shall be in compliance with section 15.211 no... later than September 1, 1979. (f) Action on the part of Sun Oil Company, Apco Oil Corporation...
40 CFR 52.1931 - Petroleum storage tank controls.
Code of Federal Regulations, 2012 CFR
2012-07-01
... storage at the Sun Oil Company refinery at Duncan, Oklahoma, shall be in compliance with section 15.211 no... later than September 1, 1979. (f) Action on the part of Sun Oil Company, Apco Oil Corporation...
40 CFR 52.1931 - Petroleum storage tank controls.
Code of Federal Regulations, 2010 CFR
2010-07-01
... storage at the Sun Oil Company refinery at Duncan, Oklahoma, shall be in compliance with section 15.211 no... later than September 1, 1979. (f) Action on the part of Sun Oil Company, Apco Oil Corporation...
Efficiency and impacts of hythane (CH4+H2) underground storage
NASA Astrophysics Data System (ADS)
Sáinz-García, Alvaro; Abarca, Elena; Grandia, Fidel
2016-04-01
The foreseen increase share of renewable energy production requires energy storage to mitigate shortage periods of energy supply. Hydrogen is an efficient energy carrier that can be transported and storage. A very promising way to store large amounts of hydrogen is underground geological reservoirs. Hydrogen can be stored, among other options, as a mixture of natural gas and less than 20% of hydrogen (hythane) to avoid damages on the existing infrastructure for gas transport. This technology is known as power-to-gas and is being considered by a number of European countries (Simon et al., 2015). In this study, the feasibility of a deep aquifer to store CH4-H2 mixtures in the Lower Triassic of the Paris Basin is numerically analyzed. The solubility of gas mixture in the groundwater is extremely low (Panfilov, 2015) and, therefore, gas and water are considered immiscible and non-reactive. An immiscible multiphase flow model is developed using the coefficient-form PDE interface of the finite element method code, COMSOL Multiphysics. The modelled domain is a 2D section of 2500 x 290 m resembling the Lower Triassic aquifer of the Paris basin, consisting of 2 layers of sandstone separated by a layer of conglomerates. The domain dips 0.5% from east to west. The top of the aquifer is 500 m-deep and the lateral boundaries are assumed to be open. This case is considered conservative compared to a dome-like geological trap, which could be more favorable to retain higher gas concentration. A number of cycles of gas production and injection were modelled. An automatic shut-down of the pump is implemented in case pressure on the well exceeds an upper or lower threshold. The influence of the position of the well, the uncertain residual gas saturation and the regional flow are studied. The model shows that both gas and aquifer properties have a significant impact on storage. Due to its low viscosity, the mobility of the hythane is quite high and gas expands significantly, reducing the maximum gas saturation during injection/production cycles. The storage efficiency is hindered by inactivity periods. Furthermore, the gas fate is extremely affected by regional groundwater flow. References Panfilov, M., 2015. Underground and pipeline hydrogen storage, in: Gupta, R., Basile, A., Veziroglu, T.N. (Eds.), Compendium of Hydrogen Energy. Woodhead Publishing, pp. 91-116. Simon, J., Ferriz, A.M., Correas, L.C., 2015. HyUnder - Hydrogen Underground Storage at Large Scale: Case Study Spain. Energy Procedia. 73, 136 - 144.
Hydrodynamic modeling of petroleum reservoirs using simulator MUFITS
NASA Astrophysics Data System (ADS)
Afanasyev, Andrey
2015-04-01
MUFITS is new noncommercial software for numerical modeling of subsurface processes in various applications (www.mufits.imec.msu.ru). To this point, the simulator was used for modeling nonisothermal flows in geothermal reservoirs and for modeling underground carbon dioxide storage. In this work, we present recent extension of the code to petroleum reservoirs. The simulator can be applied in conventional black oil modeling, but it also utilizes a more complicated models for volatile oil and gas condensate reservoirs as well as for oil rim fields. We give a brief overview of the code by providing the description of internal representation of reservoir models, which are constructed of grid blocks, interfaces, stock tanks as well as of pipe segments and pipe junctions for modeling wells and surface networks. For conventional black oil approach, we present the simulation results for SPE comparative tests. We propose an accelerated compositional modeling method for sub- and supercritical flows subjected to various phase equilibria, particularly to three-phase equilibria of vapour-liquid-liquid type. The method is based on the calculation of the thermodynamic potential of reservoir fluid as a function of pressure, total enthalpy and total composition and storing its values as a spline table, which is used in hydrodynamic simulation for accelerated PVT properties prediction. We provide the description of both the spline calculation procedure and the flashing algorithm. We evaluate the thermodynamic potential for a mixture of two pseudo-components modeling the heavy and light hydrocarbon fractions. We develop a technique for converting black oil PVT tables to the potential, which can be used for in-situ hydrocarbons multiphase equilibria prediction under sub- and supercritical conditions, particularly, in gas condensate and volatile oil reservoirs. We simulate recovery from a reservoir subject to near-critical initial conditions for hydrocarbon mixture. We acknowledge financial support by a Grant from the president of the Russian Federation (SP-2222.2012.5) and by Russian foundation for basic research (RFBR 15-31-20585).
Code of Federal Regulations, 2010 CFR
2010-07-01
... (ABC) fire extinguishers that are listed or approved by a nationally recognized independent testing... (ABC) fire extinguishers that are listed or approved by a nationally recognized independent testing... storage; and (4) Maintained to prevent the accumulation of water. (c) Welding or cutting other than that...
DOT National Transportation Integrated Search
2017-06-01
The Virginia Department of Transportation (VDOT) collects millions of gallons of runoff at its nearly 300 salt storage : facilities each year, with some portion of this water being reused for the generation of salt brine. Storing this collected storm...
NASA Astrophysics Data System (ADS)
Tulebekova, S.; Saliyev, D.; Zhang, D.; Kim, J. R.; Karabay, A.; Turlybek, A.; Kazybayeva, L.
2017-11-01
Compressed air energy storage technology is one of the promising methods that have high reliability, economic feasibility and low environmental impact. Current applications of the technology are mainly limited to energy storage for power plants using large scale underground caverns. This paper explores the possibility of making use of reinforced concrete pile foundations to store renewable energy generated from solar panels or windmills attached to building structures. The energy will be stored inside the pile foundation with hollow sections via compressed air. Given the relatively small volume of storage provided by the foundation, the required storage pressure is expected to be higher than that in the large-scale underground cavern. The high air pressure typically associated with large temperature increase, combined with structural loads, will make the pile foundation in a complicated loading condition, which might cause issues in the structural and geotechnical safety. This paper presents a preliminary analytical study on the performance of the pile foundation subjected to high pressure, large temperature increase and structural loads. Finite element analyses on pile foundation models, which are built from selected prototype structures, have been conducted. The analytical study identifies maximum stresses in the concrete of the pile foundation under combined pressure, temperature change and structural loads. Recommendations have been made for the use of reinforced concrete pile foundations for renewable energy storage.
Kennedy, Jeffrey R.; Koth, Karl R.; Carruth, Rob
2015-01-01
Absolute gravity data were collected at 32 stations in the vicinity of the Sanford Underground Research Facility from 2007 through 2014 for the purpose of monitoring groundwater storage change during dewatering of the former Homestake gold mine in the Black Hills of South Dakota, the largest and deepest underground mine in North America. Eight underground stations are at depths from 300 feet below land surface to 4,850 feet below land surface. Surface stations were located using Global Positioning System observations, and subsurface stations were located on the basis of maps constructed from survey measurements made while the mine was in operation. Gravity varies widely at many stations; however, no consistent temporal trends are present across all stations during the 7-year period of data collection.
90. VIEW NORTHEAST OF BUILDING 98 OIL HOUSE AND STORAGE ...
90. VIEW NORTHEAST OF BUILDING 98 OIL HOUSE AND STORAGE TANK; OIL FOR POWER GENERATION WAS UNLOADED FROM TANK CARS AND STORED AT THIS FACILITY - Scovill Brass Works, 59 Mill Street, Waterbury, New Haven County, CT
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-17
... Spearmint Oil Produced in the Far West; Change to Administrative Rules Regarding the Transfer and Storage of... Committee or its designees for storage from November 1 to December 1. This action would also change the date... such oil to the Committee or its designees for storage from November 1 to December 1. This rule would...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bryce, David A.; Shao, Hongbo; Cantrell, Kirk J.
2016-06-07
CO2 injected into depleted oil or gas reservoirs for long-term storage has the potential to mobilize organic compounds and distribute them between sediments and reservoir brines. Understanding this process is important when considering health and environmental risks, but little quantitative data currently exists on the partitioning of organics between supercritical CO2 and water. In this work, a high-pressure, in situ measurement capability was developed to assess the distribution of organics between CO2 and water at conditions relevant to deep underground storage of CO2. The apparatus consists of a titanium reactor with quartz windows, near-infrared and UV spectroscopic detectors, and switchingmore » valves that facilitate quantitative injection of organic reagents into the pressurized reactor. To demonstrate the utility of the system, partitioning coefficients were determined for benzene in water/supercritical CO2 over the range 35-65 °C and approximately 25-150 bar. Density changes in the CO2 phase with increasing pressure were shown to have dramatic impacts on benzene's partitioning behavior. Our partitioning coefficients were approximately 5-15 times lower than values previously determined by ex situ techniques that are prone to sampling losses. The in situ methodology reported here could be applied to quantify the distribution behavior of a wide range of organic compounds that may be present in geologic CO2 storage scenarios.« less
Aedes aegypti breeding site in an underground rainwater reservoir: a warning
Bermudi, Patricia Marques Moralejo; Kowalski, Fernanda; Menzato, Marcela Mori; Ferreira, Millene da Cruz; dos Passos, Willian Brendo Silva; Oku, Vivian Janine Ambriola; Kumow, Aline; Lucio, Taís Vargas Freire Martins; Lima-Camara, Tamara Nunes; Urbinatti, Paulo Roberto; Chiaravalloti, Francisco
2017-01-01
ABSTRACT We describe the discovery of Aedes aegypti underground breeding site in the Pinheiros neighborhood of São Paulo, SP, during an entomological survey program performed in 2016. Even with intense surveillance and vector control, large numbers of mosquitoes were present in this area. A detailed investigation allowed for the detection of Ae. aegypti in an underground reservoir used for rainwater storage. After the implementation of protection screens in the accesses, the presence of the vector was no longer detected. In this study, we discuss the frequent use of this type of reservoir structure and its risk for mosquito production. PMID:29236877
A nuclear wind/solar oil-shale system for variable electricity and liquid fuels production
DOE Office of Scientific and Technical Information (OSTI.GOV)
Forsberg, C.
2012-07-01
The recoverable reserves of oil shale in the United States exceed the total quantity of oil produced to date worldwide. Oil shale contains no oil, rather it contains kerogen which when heated decomposes into oil, gases, and a carbon char. The energy required to heat the kerogen-containing rock to produce the oil is about a quarter of the energy value of the recovered products. If fossil fuels are burned to supply this energy, the greenhouse gas releases are large relative to producing gasoline and diesel from crude oil. The oil shale can be heated underground with steam from nuclear reactorsmore » leaving the carbon char underground - a form of carbon sequestration. Because the thermal conductivity of the oil shale is low, the heating process takes months to years. This process characteristic in a system where the reactor dominates the capital costs creates the option to operate the nuclear reactor at base load while providing variable electricity to meet peak electricity demand and heat for the shale oil at times of low electricity demand. This, in turn, may enable the large scale use of renewables such as wind and solar for electricity production because the base-load nuclear plants can provide lower-cost variable backup electricity. Nuclear shale oil may reduce the greenhouse gas releases from using gasoline and diesel in half relative to gasoline and diesel produced from conventional oil. The variable electricity replaces electricity that would have been produced by fossil plants. The carbon credits from replacing fossil fuels for variable electricity production, if assigned to shale oil production, results in a carbon footprint from burning gasoline or diesel from shale oil that may half that of conventional crude oil. The U.S. imports about 10 million barrels of oil per day at a cost of a billion dollars per day. It would require about 200 GW of high-temperature nuclear heat to recover this quantity of shale oil - about two-thirds the thermal output of existing nuclear reactors in the United States. With the added variable electricity production to enable renewables, additional nuclear capacity would be required. (authors)« less
Cavity degradation risk insurance assessment. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hampson, C.; Neill, P.; de Bivort, L.
1980-01-01
This study examined the risks and risk management issues involved with the implementation by electric power utilities of compressed air energy storage and underground pumped hydro storage systems. The results are listed in terms of relative risks for the construction and operation of these systems in different geologic deposits, with varying amounts of pressurization, with natural or man-made disasters in the vicinity of the storage equipment, and with different modes of operating the facilities. (LCL)
2004-10-01
218-681-1903 GOOD F Larimore is experienced and Servers shihs. "Meet me Good Friends 701-343-2987. ll’T II,_ ;_, -’ rELINE BI~AR HOROSCOPE ...never given a wish without also being given the power to make it come true . You may have to work for it, however. " -- Richard Bach -----Original
Salt dissolution sinkhole at the Weeks Island, Louisiana, Strategic Petroleum Reserve storage site
DOE Office of Scientific and Technical Information (OSTI.GOV)
Neal, J.T.; Myers, R.E.
1994-12-31
A sinkhole was first observed in May 1992 over the outer edge of the two-tiered former salt mine that was converted for oil storage by the US Strategic Petroleum Reserve (SPR). Results of diagnostic studies which included geophysical, geochemical, drilling, and hydrological methods suggest a direct connection exists between the surface collapse area and the underground mine. The connection was confirmed by correlative measurements of sediment slump rates, piezometric surface deflection, and brine influx rates into the mine. The dissolution of salt below the sinkhole that initiated the leak into the mine was likely caused by several confluent geologic processes,more » and exacerbated by mining-induced stresses that created fractures which severed as hydrologic flowpaths. Modeling studies of mine stresses show that years of tensional stresses may be required before cracking begins to occur, but once begun can continue to develop, and relieve the stress in that specific regime. The crack regime creates the avenue for incursion of groundwater, very slowly initially, but gradually enlarging as undersaturated groundwater dissolves salt on the sides of the crack. Mitigative measures include increasing the mine pressurization, slowing the dissolution by injecting brine into the sinkhole throat, and permeation grouting in hydrologic flowpaths.« less
Classification of CO2 Geologic Storage: Resource and Capacity
Frailey, S.M.; Finley, R.J.
2009-01-01
The use of the term capacity to describe possible geologic storage implies a realistic or likely volume of CO2 to be sequestered. Poor data quantity and quality may lead to very high uncertainty in the storage estimate. Use of the term "storage resource" alleviates the implied certainty of the term "storage capacity". This is especially important to non- scientists (e.g. policy makers) because "capacity" is commonly used to describe the very specific and more certain quantities such as volume of a gas tank or a hotel's overnight guest limit. Resource is a term used in the classification of oil and gas accumulations to infer lesser certainty in the commercial production of oil and gas. Likewise for CO2 sequestration, a suspected porous and permeable zone can be classified as a resource, but capacity can only be estimated after a well is drilled into the formation and a relatively higher degree of economic and regulatory certainty is established. Storage capacity estimates are lower risk or higher certainty compared to storage resource estimates. In the oil and gas industry, prospective resource and contingent resource are used for estimates with less data and certainty. Oil and gas reserves are classified as Proved and Unproved, and by analogy, capacity can be classified similarly. The highest degree of certainty for an oil or gas accumulation is Proved, Developed Producing (PDP) Reserves. For CO2 sequestration this could be Proved Developed Injecting (PDI) Capacity. A geologic sequestration storage classification system is developed by analogy to that used by the oil and gas industry. When a CO2 sequestration industry emerges, storage resource and capacity estimates will be considered a company asset and consequently regulated by the Securities and Exchange Commission. Additionally, storage accounting and auditing protocols will be required to confirm projected storage estimates and assignment of credits from actual injection. An example illustrates the use of these terms and how storage classification changes as new data become available. ?? 2009 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Utami, R.; Kawiji; Khasanah, L. U.; Solikhah, R.
2018-03-01
The aim of this study was to determine the effect of edible coating enriched with kaffir lime (Citrus hystrix DC) leaves essential oil at various concentration on beef sausage quality during frozen storage (-18°±2°C). The concentration of kaffir lime leaves essential oil enriched in edible coating were varied at 0%; 0.2%; 1.4%. Microbiological, physical and chemical characteristics (TPC, color, TBA, TVB, and pH) were investigated at 0, 1, 2, 3, and 4 months of storage. The result showed that edible coating with the addition of kaffir lime leaves essential oils decreased the microbial growth, TVB value, and TBA value of beef sausage. The color and pH of samples can be stabilized during storage. The selected kaffir lime leaves essential oil concentrations based on microbial, physical, and chemical characteristics of beef sausages during frozen storage at -18°C was 0.2%.
An assessment of subsurface contamination of an urban coastal aquifer due to oil spill.
Nambi, Indumathi M; Rajasekhar, Bokam; Loganathan, Vijay; RaviKrishna, R
2017-04-01
Incidences of leakages of chemicals from underground oil storage tanks or oil-carrying pipelines have posed huge threat to the coastal aquifers around the world. One such leak was recently identified and notified by the people of Tondiarpet, Chennai, India. The assessment of the contamination level was done by obtaining electrical resistivity maps of the subsurface, drilling of 20 new borewells for soil and water analysis, and testing the water quality of 30 existing borewells. Samples were collected from the borewells, and observations were made that included parameters such as odor, moisture, contamination characteristics, lithology, groundwater level, thickness of the free product that are used to demarcate the extent of soil, and water contamination. Furthermore, a multigas detector was used to detect hydrocarbon presence as soil vapor. Moreover, to capture the transport of dissolved hydrocarbons, 10 samples were collected in the periphery of the study area and were analyzed for the presence of petroleum hydrocarbon and polyaromatic hydrocarbon. Analysis of the data indicated the presence of free-phase hydrocarbon in soil and groundwater close to the junction of Thiruvottiyur high (TH) road (TH) and Varadaja Perumal Koil (VPK) street. Although the contaminant plume is confined to a limited area, it has spread more to the southern and eastern side of the pipeline possibly due to continuous abstraction of groundwater by residential apartments. After cutting a trench along the VPK street and plotting of the plume delineation map, observations indicated that the source of the hydrocarbon leak is present in VPK street close to TH road. A multipronged strategy was suggested targeting the remediation of oil in various phases.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Heath, Jason E.; Dewers, Thomas; Chidsey, Thomas C.
Greater Aneth oil field, Utah’s largest oil producer, was discovered in 1956 and has produced over 483 million barrels of oil. Located in the Paradox Basin of southeastern Utah, Greater Aneth is a stratigraphic trap producing from the Pennsylvanian (Desmoinesian) Paradox Formation. Because Greater Aneth is a mature, major oil field in the western U.S., and has a large carbonate reservoir, it was selected to demonstrate combined enhanced oil recovery and carbon dioxide storage. The Aneth Unit in the northwestern part of the field has produced over 160 million barrels of the estimated 386 million barrels of original oil inmore » place—a 42% recovery rate. The large amount of remaining oil made the Aneth Unit ideal to enhance oil recovery by carbon dioxide flooding and demonstrate carbon dioxide storage capacity.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-26
... total storage capacity of 5,737 acre-feet at a normal maximum operating elevation of 1,600 feet mean sea level (msl); (2) five 9,700-foot-long, 25-foot- diameter steel lined penstocks extending between the... Ocean, serving as the lower reservoir; (4) an underground powerhouse with approximate dimensions of 250...
Working and Net Available Shell Storage Capacity
2017-01-01
Working and Net Available Shell Storage Capacity is the U.S. Energy Information Administration’s (EIA) report containing storage capacity data for crude oil, petroleum products, and selected biofuels. The report includes tables detailing working and net available shell storage capacity by type of facility, product, and Petroleum Administration for Defense District (PAD District). Net available shell storage capacity is broken down further to show the percent for exclusive use by facility operators and the percent leased to others. Crude oil storage capacity data are also provided for Cushing, Oklahoma, an important crude oil market center. Data are released twice each year near the end of May (data for March 31) and near the end of November (data for September 30).
Wilson, Sacoby; Zhang, Hongmei; Burwell, Kristen; Samantapudi, Ashok; Dalemarre, Laura; Jiang, Chengsheng; Rice, LaShanta; Williams, Edith; Naney, Charles
2014-01-01
There are approximately 590,000 underground storage tanks (USTs) nationwide that store petroleum or hazardous substances. Many of these tanks are leaking, which may increase the risk of exposure to contaminants that promote health problems in host neighborhoods. Within this study, we assessed disparities in the spatial distribution of leaking underground storage tanks (LUSTs) based on socioeconomic status (SES) and race/ethnicity in South Carolina (SC). Chi-square tests were used to evaluate the difference in the proportion of populations who host a LUST compared to those not hosting a LUST for all sociodemographic factors. Linear regression models were applied to examine the association of distance to the nearest LUST with relevant sociodemographic measures. As percent black increased, the distance (both in kilometers and miles) to the nearest LUST decreased. Similar results were observed for percent poverty, unemployment, persons with less than a high school education, blacks in poverty, and whites in poverty. Furthermore, chi-square tests indicated that blacks or non-whites or people with low SES were more likely to live in LUST host areas than in non-host areas. As buffer distance increased, percent black and non-white decreased. SES variables demonstrated a similar inverse relationship. Overall, burden disparities exist in the distribution of LUSTs based on race/ethnicity and SES in SC. PMID:24729829
DOE Office of Scientific and Technical Information (OSTI.GOV)
Washenfelder, D. J.; Johnson, J. M.; Turknett, J. C.
In addition to managing the 177 underground waste storage tanks containing 212,000 m3 (56 million gal) of radioactive waste at the U. S. Department of Energy’s Hanford Site 200 Area Tank Farms, Washington River Protection Solutions LLC is responsible for managing numerous small catch tanks and special surveillance facilities. These are collectively known as “MUSTs” - Miscellaneous Underground Storage Tanks. The MUSTs typically collected drainage and flushes during waste transfer system piping changes; special surveillance facilities supported Tank Farm processes including post-World War II uranium recovery and later fission product recovery from tank wastes. Most were removed from service followingmore » deactivation of the single-shell tank system in 1980 and stabilized by pumping the remaining liquids from them. The MUSTs were isolated by blanking connecting transfer lines and adding weatherproofing to prevent rainwater entry. Over the next 30 years MUST operating records were dispersed into large electronic databases or transferred to the National Archives Regional Center in Seattle, Washington. During 2014 an effort to reacquire the historical bases for the MUSTs’ published waste volumes was undertaken. Corporate Memory Recovery from a variety of record sources allowed waste volumes to be initially determined for 21 MUSTs, and waste volumes to be adjusted for 37 others. Precursors and symptoms of Corporate Memory Loss were identified in the context of MUST records recovery.« less
Froese, Carol D; Nowack, Linda; Cholewa, Ewa; Thompson, John E
2003-03-01
Lipid particles have been isolated from seeds of wax bean (Phaseolus vulgaris), a species in which starch and protein rather than lipid are the major seed storage reserves. These lipid particles resemble oil bodies present in oil-rich seeds in that > 90% of their lipid is triacylglycerol. Moreover, this triacylglycerol is rapidly metabolized during seed germination indicating that it is a storage reserve. The phospholipid surfaces of oil bodies are known to be completely coated with oleosin which prevents their coalescence, particularly during desiccation of the developing seed. This would appear to be necessary since lipid is the major storage reserve in oil seeds, and there are very few alternate types of storage particles in the cytoplasm of oil seed endosperm to provide a buffer against coalescence of oil bodies by isolating them from one another. The present study indicates that the surfaces of lipid particles from wax bean are not completely coated with oleosin and feature regions of naked phospholipid. This finding has been interpreted as reflecting the fact that lipid particles in wax been seeds are less prone to coalescence than oil bodies of oil-rich seeds. This arises because the individual lipid particles are interspersed in situ among highly abundant protein bodies and starch grains and hence less likely to come in contact with one another, even during desiccation of the developing seed.
Early detection of mine fire in underground by using smell detectors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ohga, Kotaro; Higuchi, Kiyoshi
1995-12-31
In our laboratory, a new detection system using smell detectors was developed to detect the spontaneous combustion of coal and the combustion of other materials used underground. Laboratory experiments were carried out on several kinds of coals, including South African coals, and machine oil, wood and rubber used in belt conveyers. The following results were obtained: (1) Spontaneous combustion of coal can be detected earlier by smell detectors than by conventional CO detection methods. (2) There were no differences in the results using different kinds of coal. (3) Combustion d other materials can also be detected earlier by this systemmore » than by conventional detectors for gas and smoke. (4) Use of this detection system enables one to discern the source of the combustion gases, whether it be coal, wood, oil or rubber.« less
NASA Astrophysics Data System (ADS)
Ou, Yihong; Du, Yang; Jiang, Xingsheng; Wang, Dong; Liang, Jianjun
2010-04-01
The study on the special phenomenon, occurrence process and control mechanism of gasoline-air mixture thermal ignition in underground oil depots is of important academic and applied value for enriching scientific theories of explosion safety, developing protective technology against fire and decreasing the number of fire accidents. In this paper, the research on thermal ignition process of gasoline-air mixture in model underground oil depots tunnel has been carried out by using experiment and numerical simulation methods. The calculation result has been demonstrated by the experiment data. The five stages of thermal ignition course, which are slow oxidation stage, rapid oxidation stage, fire stage, flameout stage and quench stage, have been firstly defined and accurately descried. According to the magnitude order of concentration, the species have been divided into six categories, which lay the foundation for explosion-proof design based on the role of different species. The influence of space scale on thermal ignition in small-scale space has been found, and the mechanism for not easy to fire is that the wall reflection causes the reflux of fluids and changes the distribution of heat and mass, so that the progress of chemical reactions in the whole space are also changed. The novel mathematical model on the basis of unification chemical kinetics and thermodynamics established in this paper provides supplementary means for the analysis of process and mechanism of thermal ignition.
Studies of soil and ecohydrological processes in oil-gas production regions.
NASA Astrophysics Data System (ADS)
Khodyreva, E. Ya.; Khodyrev, Yu. P.
2009-04-01
For a better understanding and describing of the functional interactions between processes in soil and drinking, underground and stratum waters in oil-gas production regions we used laboratory and field monitoring methods of studies. The control of ecological situation dynamics in oil-gas production regions proposes a presence of primary data about parameter-indicators, which characterize a state of the object under investigation. One of these parameters is the concentration of heavy metal salts in drinking and stratum waters. Isolation of some compounds, which are extracted as impurities of oil and water during recovery of hydrocarbons from productive horizons, would enhance profitableness of recovery. Because accompanying impurities are a mixture of different salts and complexes, the methods of multielement analysis give the most objective evaluation of total content of some elements by search and prospecting. The developed method of laser mass-spectrometric analysis of oil and drinking, underground and industrial waters allows to investigate the samples on all elements of the periodical system simultaneously with limit sensitivity 0.1 mkg/l. The preparation of the oil and water probes was carried out by sublimation of highly volatile fractions in vacuum at 100 0C. The samples of drinking and underground waters, oils and industrial waters from wells of oil field Romashkin (Tatarstan) were chosen as the object for the research. In respect to possible metal extraction scandium is of most interest in inspected area because it's very high cost and availability of water-soluble pattern, most probably chloride. Its concentration in one well was 1 mg/l in water and 0.01 mg/l in oil. According to the received data of laser mass-spectrometric analysis, industrial waters on the activity investigated territory joint-stock company "Tatneft" contain 220-330 kg / ton of salts of metals that does by their potential source of alternative raw material for the chemical industry. Soil is an important component of the earth's biosphere because of its crucial role in the hydrological cycle. For revealing possible correlation between spatial distributions of the valuable elements contained both in industrial waters and in tests of soils, 79 samples are prepared and investigated. These tests are selected at superficial geochemical shooting (field monitoring methods of studies) Aznakaevskoi, Karamalinskoi and Sabanchinskoi areas of joint-stock company " Tatneft ". Circuits of distribution of valuable elements on the investigated territory are constructed also a quantitative estimation of the maintenance makro- and microcomponents is given. From the found out elements the greatest interest Na, Mg, K, Ca, Cl, Br and their connections represent because of very high concentration and scandium owing to the cost. Now cost of scandium in the world market approximately in 25 times exceeds cost of gold and is not observed yet tendencies to its decrease. Presence of impurity of salts of heavy metals and their connections in soils, drinking, underground and stratum waters, definition of their concentration and comparison from maximum concentration limit allows to establish the control over dynamics of ecohydrological conditions and in due time to take measures on reduction of negative influence of processes of development of hydrocarbon raw material by an environment.
Advanced underground Vehicle Power and Control: The locomotive Research Platform
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vehicle Projects LLC
2003-01-28
Develop a fuelcell mine locomotive with metal-hydride hydrogen storage. Test the locomotive for fundamental limitations preventing successful commercialization of hydride fuelcells in underground mining. During Phase 1 of the DOE-EERE sponsored project, FPI and its partner SNL, completed work on the development of a 14.4 kW fuelcell power plant and metal-hydride energy storage. An existing battery-electric locomotive with similar power requirements, minus the battery module, was used as the base vehicle. In March 2001, Atlas Copco Wagner of Portland, OR, installed the fuelcell power plant into the base vehicle and initiated integration of the system into the vehicle. The entiremore » vehicle returned to Sandia in May 2001 for further development and integration. Initial system power-up took place in December 2001. A revision to the original contract, Phase 2, at the request of DOE Golden Field Office, established Vehicle Projects LLC as the new prime contractor,. Phase 2 allowed industry partners to conduct surface tests, incorporate enhancements to the original design by SNL, perform an extensive risk and safety analysis, and test the fuelcell locomotive underground under representative production mine conditions. During the surface tests one of the fuelcell stacks exhibited reduced power output resulting in having to replace both fuelcell stacks. The new stacks were manufactured with new and improved technology resulting in an increase of the gross power output from 14.4 kW to 17 kW. Further work by CANMET and Hatch Associates, an engineering consulting firm specializing in safety analysis for the mining industry, both under subcontract to Vehicle Projects LLC, established minimum requirements for underground testing. CANMET upgraded the Programmable Logic Control (PLC) software used to monitor and control the fuelcell power plant, taking into account locomotive operator's needs. Battery Electric, a South Africa manufacturer, designed and manufactured (at no cost to the project) a new motor controller capable of operating the higher rpm motor and different power characteristics of the fuelcells. In early August 2002, CANMET, with the technical assistance of Nuvera Fuel Cells and Battery Electric, installed the new PLC software, installed the new motor controller, and installed the new fuelcell stacks. After minor adjustments, the fuelcell locomotive pulled its first fully loaded ore cars on a surface track. The fuelcell-powered locomotive easily matched the battery powered equivalent in its ability to pull tonnage and equaled the battery-powered locomotive in acceleration. The final task of Phase 2, testing the locomotive underground in a production environment, occurred in early October 2002 in a gold mine. All regulatory requirements to allow the locomotive underground were completed and signed off by Hatch Associates prior to going underground. During the production tests, the locomotive performed flawlessly with no failures or downtime. The actual tests occurred during a 2-week period and involved moving both gold ore and waste rock over a 1,000 meter track. Refueling, or recharging, of the metal-hydride storage took place on the surface. After each shift, the metal-hydride storage module was removed from the locomotive, transported to surface, and filled with hydrogen from high-pressure tanks. The beginning of each shift started with taking the fully recharged metal-hydride storage module down into the mine and re-installing it onto the locomotive. Each 8 hour shift consumed approximately one half to two thirds of the onboard hydrogen. This indicates that the fuelcell-powered locomotive can work longer than a similar battery-powered locomotive, which operates about 6 hours, before needing a recharge.« less
Effect of containers on the quality of Chemlali olive oil during storage.
Gargouri, Boutheina; Zribi, Akram; Bouaziz, Mohamed
2015-04-01
This study is undertaken to determine the storage stability of Chemlali extra-virgin olive oil (EVOO) in different containers such as clear and dark glass bottles, polyethylene (PE) and tin containers. The different oil samples were stored under light at room temperature. Quality parameters monitored during a 6-month-storage period included: acidity, peroxide value (PV), spectrophotometric indices (K232 and K270), chlorophyll and carotene pigments, fatty acids and sterol compositions, total phenols, Rancimat induction time as well as sensory evaluation. Tin containers and dark glass bottles recorded the lowest oxidation values. In addition, oil packed in tin containers and dark glass bottles showed better physicochemical and organoleptic characteristics than that stored in clear glass bottles and PE containers. A significant decrease (p < 0.05) in the antioxidant contents (carotenes, chlorophylls and total phenols) was observed in the oil stored in the clear glass bottles and PE containers. Such results proved that the storage of oil in tin containers and dark glass bottles appeared most adequate, and showed a gradual loss of quality during storage, especially in PE containers and clear glass bottles. This study has shown that the best packaging materials for the commercial packing of Chemlali extra-virgin olive oil are tin containers and dark glass bottles.
The Soviet Program for Peaceful Uses of Nuclear Explosions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nordyke, M.D.
2000-07-26
During a period of some 23 years between 1965 and 1988, the Soviet Union's ''Program for the Utilization of Nuclear Explosions in the National Economy'' carried out 122 nuclear explosions to study and put into industrial use some 13 applications. In all, 128 explosives with yields ranging from 0.01 to 140 kt were used, with the vast majority being between 2 and 20 kt. Most peaceful applications of nuclear explosions in the Soviet PNE Program were explored in depth with a number of tests, but unfortunately little has been reported on the technical results other than general outcomes. Two applications,more » deep seismic sounding of the Earth's crust and upper mantle and the creation of underground cavities in salt for the storage of gas condensate, found widespread use, representing over 50% of all the explosions. Explosions to explore the technical possibilities of stimulating the production of oil and gas reservoirs accounted for an additional 17%.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
The objectives of the closure assessment were to determine the extent of contaminated soil adjacent to the USTs requiring excavation, to provide documentation of soil and groundwater conditions following excavation, and to document closure activities in accordance with applicable VADEQ regulations. During closure activities, ASI provided technical support to the Base to ensure that the UST removal contractor (E K, Inc.) hereinafter referred to as the Contractor was in compliance with the technical requirements (as specified in the Plans and Specifications for Removal of Abandoned Underground Storage Tanks, Virginia Air National Guard, Richmond International Airport, Sandston, VA., dated July 1991more » and revised April 1992, and Addendum Numbers 1 through 7) of the contract. ASI was also responsible for collecting soil and/or groundwater closure samples from the excavations, and providing off-site fixed based laboratory analysis to verify clean conditions within the excavations.« less
Natural gas monthly, March 1991. [Glossary included
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1991-03-01
The Natural Gas Monthly (NGM) is prepared in the Data Operations Branch of the Reserves and Natural Gas Division, Office of Oil and Gas, Energy Information Administration (EIA), US Department of Energy (DOE). The NGM highlights activities, events and analyses of interest to public and private sector organizations associated with the natural gas industry. Volume and price data are presented each month for natural gas production, distribution, consumption, and interstate pipeline activities. Producer-related activities and underground storage data are also reported. From time to time, the NGM features articles designed to assist readers in using and interpreting natural gas information.more » This month's article is an update on natural gas distribution services. Explanatory Notes supplement the information found in tables of the report. A description of the data collection surveys that support the NGM is provided in the Data Sources section. A glossary of the terms used in this report is also provided to assist readers in understanding the data presented in this publication. 9 figs., 39 tabs.« less
Thermal and storage characteristics of tomato seed oil
USDA-ARS?s Scientific Manuscript database
Thermal oxidative stability and effect of different storage conditions on quality characteristics of tomato seed oil have not been studied. The objectives of this research were to determine the changes in quality and oxidative stability of tomato seed oil, including color, antioxidant activity, per...
Stability of omega-3 fatty acids in fortified surimi seafoods during chilled storage.
Pérez-Mateos, Miriam; Boyd, Leon; Lanier, Tyre
2004-12-29
Physical, chemical, and sensory properties of cooked surimi seafood gels (crab analogue) fortified with omega-3 fatty acids (FA) were monitored during chilled storage. Three sources of stabilized omega-3 FA (fish oil concentrate, menhaden oil, and a purified marine oil) were each incorporated into gels to an omega-3 FA content of 1.5 or 2.5%, w/w. Omega-3 FA stability, development of off-flavors, and changes in color and texture were monitored during chilled storage for 2 months. Gels with fish oil concentrate developed fishy flavor and aroma within 30 days and were eliminated from the study. Gels containing menhaden oil and purified marine oil exhibited little change in sensory properties or oxidation products throughout 2 months of storage. Relative polyene index values (ratio of polyunsaturated to saturated fatty acids) indicated that the omega-3 FA were stable at both levels of addition. Omega-3 fortified gels were whiter than control gels, and gel texture was modified when menhaden and purified oils were added but not significantly affected by the level of omega-3 addition.
ERIC Educational Resources Information Center
Beard, J. Taylor; And Others
This report is part of a series from the Department of Energy on the use of solar energy in heating buildings. Described here is a new system for year around collection and storage of solar energy. This system has been operated at the University of Virginia for over a year. Composed of an underground hot water storage system and solar collection,…
NASA Astrophysics Data System (ADS)
Erwin; Wahifiyah, E.; Hairani, R.; Panggabean, A. S.
2018-04-01
The purpose of this study was to determine the effect of the crude extract of tea leaves (Camellia sinensis L.) and storage time on the content of free fatty acid in palm oil. The dried tea leaves were macerated and concentrated by rotary evaporator. The extract obtained was added to crude palm oil with various added mass of the extract and various storage times. Phytochemical tests indicated the presence of secondary metabolites including alkaloids, triterpenoids, steroids, phenolics and flavonoids. The ANOVA test showed a decrease in free fatty acid content in crude palm oil with the addition of tea leaves extract. The LSD (Least Significant Difference) test showed the best influence on ALB of palm oil is on the total extract mass of 2 grams and the storage time of 20 days.
Morales-Sillero, Ana; Pérez, Ana G; Casanova, Laura; García, José M
2017-12-15
The suitability of the cold storage (2°C) of fruit to maintain the quality of 'Manzanilla de Sevilla' and 'Manzanilla Cacereña' intended for virgin olive oil extraction was investigated. This temperature was effective in keeping the best commercial category of oil quality in both manually harvested olives and in mechanically harvested 'Manzanilla Cacereña' fruits for 11days. Mechanical harvesting induced significant decreases in oxidative stability and in the main phenolic compounds contents in the oils during cold storage and, only initially, in the total volatiles, regardless of the cultivar considered. However, the contents of volatile esters, associated to fruity flavor, were always higher in the oils from mechanically harvested fruits. 'Manzanilla de Sevilla' oils exhibited higher total volatiles during fruit cold storage, regardless of the harvesting system used. Copyright © 2017 Elsevier Ltd. All rights reserved.
Panigrahi, Jitendriya; Patel, Mansi; Patel, Niyati; Gheewala, Bhumi; Gantait, Saikat
2018-06-01
This study, for the first time, evaluates the efficiency of castor oil when used as an external coating on Capsicum annuum L., to increase postharvest storage-life at 4 ± 1 °C. The castor oil-coated fruits were successfully stored for 36 days, while the non-coated fruits could only sustain for 18 days. Throughout the storage period (at 9-day intervals), different antioxidants and biochemical assays (allied with storage) such as titratable acidity, ascorbic acid content, ferrous ion chelating activity, reducing power, DPPH scavenging activity, hydroxyl radical scavenging activity, total phenolic content, total sugar estimation, and enzymatic study of polyphenol oxidase and pectate lyase, were assessed. During storage, the castor oil-coated fruits showed a substantial decrease in titratable acidity, ascorbic acid content, total phenolic content, including antioxidant activities such as reducing power and DPPH activity; however, an increase in ferrous ion chelating activity, total soluble sugar content, polyphenol oxidase activity and initial pectate lyase activity was observed, in contrast to that of the non-coated fruits. The application of castor oil proved to be effective in delaying the ripening process of fruits during storage.
Fuelcell-Hybrid Mine loader (LHD)
DOE Office of Scientific and Technical Information (OSTI.GOV)
James L Dippo; Tim Erikson; Kris Hess
2009-07-10
The fuel cell hybrid mine loader project, sponsored by a government-industry consortium, was implemented to determine the viability of proton exchange membrane (PEM) fuel cells in underground mining applications. The Department of Energy (DOE) sponsored this project with cost-share support from industry. The project had three main goals: (1) to develop a mine loader powered by a fuel cell, (2) to develop associated metal-hydride storage and refueling systems, and (3) to demonstrate the fuel cell hybrid loader in an underground mine in Nevada. The investigation of a zero-emissions fuel cell power plant, the safe storage of hydrogen, worker health advantagesmore » (over the negative health effects associated with exposure to diesel emissions), and lower operating costs are all key objectives for this project.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1994-08-01
This document is a site-specific standard request for underground storage tanks located at the Rust Garage Facility. These standards are justified based on conclusion derived from the exposure assessment that indicates there is no current or forseeable future human health risk associated with petroleum contaminants on the site, that current and future ecological risks would be generally limited to subsurface species and plant life with roots extending into the area, and that most of the impacted area at the site is covered by asphalt or concrete. The vertical and horizontal extent of soil and ground water contamination are limited tomore » immediate area of the Rust Garage Facility.« less
Storage stability of cooked sausages containing vegetable oils.
Papavergou, E J; Ambrosiadis, J A; Psomas, J
1995-01-01
Comminuted cooked sausages were produced using standard industrial practices, by substituting corn oil, sunflower oil, cotton seed oil, soybean oil and hydrogenated vegetable fat for animal fat. When processed, products were assessed for their stability with respect to autoxidation and change in organoleptic properties during vacuum-packed storage in a domestic refrigerator at 4 degrees C. Data obtained indicated that changes in thiobarbituric acid (TBA) values and organoleptic properties of products produced using corn oil, sunflower oil and hydrogenated vegetable fat were similar to those observed for reference material produced using lard. In the case of samples produced using soybean and cotton seed oil, TBA value changes were more pronounced, but did not exceed acceptable limits. A more rapid deterioration of organoleptic characteristics was also observed for the same samples, which showed flavour problems after 3 months of storage at 4 degrees C. Substitution of plant oils for lard considerably reduced the cholesterol content and increased the ratio of unsaturated to saturated fatty acids of cooked sausages.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Krokosz, M.; Sefano, J.
1993-08-01
This report presents the results of the preliminary assessment (PA) conducted by Argonne National Laboratory at the Alaska Army National Guard property known as Camp Carroll Training Center, located on the Fort Richardson Army facility near Anchorage, Alaska. Preliminary assessments of federal facilities are being conducted to compile the information necessary for the completion of preremedial activities and to provide a basis for establishing, corrective actions in response to releases of hazardous substances. The principal objective of the PA is to characterize the site accurately and determine the need for further action by examining site activities, types and quantities ofmore » hazardous substances used, the nature and amounts of wastes generated or stored at the facility, and potential pathways by which contamination could affect public health and the environment. The primary environmentally significant operations (ESOs) associated with the property are (1) the Alaska Air National Guard storage area behind Building S57112 (Organizational Maintenance Shop [OMS] 6); (2) the state of Alaska maintenance facility and the soil/tar-type spill north of the state of Alaska maintenance facility; (3) the waste storage area adjacent to OMS 6; (4) the contaminated area from leaking underground storage tanks (USTs) and the oil-water separator; and (5) soil staining in the parking area at the Camp Carroll Headquarters Building. Camp Carroll appears to be in excellent condition from an environmental standpoint, and current practices are satisfactory. Argonne recommends that the Alaska Department of Military Affairs consider remediation of soil contamination associated with all storage areas, as well as reviewing the practices of other residents of the facility. Argonne also recommends that the current methods of storing waste material behind Building S57112 (OMS 6) be reviewed for alternatives.« less
Pandey, Abhay K; Palni, Uma T; Tripathi, Nijendra N
2013-05-01
The present study aimed to evaluate the antifungal activity of 30 essential oils against four dominant fungi Aspergillus flavus Link., A. niger van Tieghem, A. ochraceus Wilhelm and A. terreus Thom of stored pigeon pea seeds at a concentration of 0.36 µL mL(-1). Various fungitoxic properties, such as minimum inhibitory concentration, minimum fungicidal concentration and fungitoxic spectrum, of the most potent oil were determined. The efficacy of the most potent oil in preservation of pigeon pea seeds for 6 months was also carried out by storing 1 kg of seeds in the oil vapour. Clausena pentaphylla and Citrus limon oils were more effective against all the fungi tested, which exhibited 100% per cent mycelial inhibition. The minimum inhibitory concentration of C. pentaphylla oil was determined as 0.07 µL mL(-1) against all the test fungi and was found to be more toxic than Citrus limon oil. C. pentaphylla oil exhibited a broad range of fungitoxicity against 16 other storage fungi of pigeon pea seeds. C. pentaphylla oil significantly protected 1 kg seeds of pigeon pea from fungal deterioration and was superior to synthetic fumigants. The oil did not show any phytotoxicity and the protein content of the seeds was significantly retained for up to 6 months of storage. Thus, C. pentaphylla oil may be used as an effective fumigant in the ecofriendly management of storage fungi of pigeon pea seeds. © 2012 Society of Chemical Industry.
Compatibility tests between Jarytherm DBT synthetic oil and solid materials from wastes
NASA Astrophysics Data System (ADS)
Fasquelle, Thomas; Falcoz, Quentin; Neveu, Pierre; Flamant, Gilles; Walker, Jérémie
2016-05-01
Direct thermocline thermal energy storage is the cheapest sensible thermal energy storage configuration. Indeed, a thermocline tank consists in one tank instead of two and reduces costs. Thermocline thermal energy storages are often filled with cheap solid materials which could react with the heat transfer fluid in the case of incompatibility. PROMES laboratory is building a pilot-scale parabolic trough solar loop including a direct thermocline thermal energy storage system. The working fluid will be a synthetic oil, the Jarytherm® DBT, and the thermal energy storage tank will be filled with stabilized solid materials elaborated from vitrified wastes. Compatibility tests have been conducted in order to check on one hand if the thermo-mechanical properties and life time of the energy storage medium are not affected by the contact with oil and, on the other hand, if the thermal oil performances are not degraded by the solid filler. These experiments consisted in putting in contact the oil and the solid materials in small tanks. In order to discriminate the solid materials tested in the shortest time, accelerating aging conditions at 330 °C for 500 hours were used. The measurements consisted in X-Ray Diffraction and Scanning Electron Microscopy for the solids, and thermo-physical and chemical properties measurements for the oil. Regarding the solid samples, their crystalline structure did not change during the test, but it is difficult to conclude about their elementary composition and they seem to absorb oil. While thermal properties still makes Jarytherm® DBT a good heat transfer fluid after the accelerated aging tests, this study results in differentiating most compatible materials. Thus according to our study, Jarytherm® DBT can be used in direct thermocline thermal energy storage applications when compatibility of the solid material has been demonstrated.
This and other periodic updates are intended to keep the public informed on major progress being made to protect public health and the environment at the Red Hill Underground Fuel Storage Facility in Hawaii.
Leif, Roald N.; Knauss, Kevin G.; Newmark, Robin L.; Aines, Roger D.; Eaker, Craig
2002-01-01
In situ hydrous pyrolysis/partial oxidation of organics at the site of the organics constrained in an subsurface reservoir produces surfactants that can form an oil/water emulsion that is effectively removed from an underground formation. The removal of the oil/water emulsions is particularly useful in several applications, e.g., soil contaminant remediation and enhanced oil recovery operations. A portion of the constrained organics react in heated reservoir water with injected steam containing dissolved oxygen gas at ambient reservoir conditions to produce such surfactants.
NASA Astrophysics Data System (ADS)
Kühn, Michael; Streibel, Martin; Nakaten, Natalie; Kempka, Thomas
2014-05-01
Massive roll-out of renewable energy production units (wind turbines and solar panels) leads to date to excess energy which cannot be consumed at the time of production. So far, long-term storage is proposed via the so called 'power-to-gas' technology. Energy is transferred to methane gas and subsequently combusted for power production - 'power-to-gas-to-power' (PGP) - when needed. PGP profits from the existing infrastructure of the gas market and could be deployed immediately. However, major shortcoming is the production of carbon dioxide (CO2) from renewables and its emission into the atmosphere. We present an innovative idea which is a decarbonised extension of the PGP technology. The concept is based on a closed carbon cycle: (1) Hydrogen (H2) is generated from renewable energy by electrolysis and (2) transformed into methane (CH4) with CO2 taken from an underground geological storage. (3) CH4 produced is stored in a second storage underground until needed and (4) combusted in a combined-cycled power plant on site. (5) CO2 is separated during energy production and re-injected into the storage formation. We studied a show case for the cities Potsdam and Brandenburg/Havel in the Federal State of Brandenburg in Germany to determine the energy demand of the entire process chain and the costs of electricity (COE) using an integrated techno-economic modelling approach (Nakaten et al. 2014). Taking all of the individual process steps into account, the calculation shows an overall efficiency of 27.7 % (Streibel et al. 2013) with total COE of 20.43 euro-cents/kWh (Kühn et al. 2013). Although the level of efficiency is lower than for pump and compressed air storage, the resulting costs are similar in magnitude, and thus competitive on the energy storage market. The great advantage of the concept proposed here is that, in contrast to previous PGP approaches, this process is climate-neutral due to CO2 utilisation. For that purpose, process CO2 is temporally stored in an underground reservoir. If existing locations in Europe, where natural gas storage in porous formations is performed, were to be extended by CO2 storage sites, a significant quantity of wind and solar energy produced could be stored as methane. The overall process chain is in this case carbon neutral. Kühn M., Nakaten N., Streibel M., Kempka T. (2013) Klimaneutrale Flexibilisierung regenerativer Überschussenergie mit Untergrundspeichern. ERDÖL ERDGAS KOHLE 129(10), 348-352. Nakaten, N., Schlüter, R., Azzam, R., Kempka, T. (2014) Development of a techno-economic model for dynamic calculation of COE, energy demand and CO2 emissions of an integrated UCG-CCS process, Energy (in press). doi: 10.1016/j.energy.2014.01.014 Streibel M., Nakaten N., Kempka T., Kühn M. (2013) Analysis of an integrated carbon cycle for storage of renewables. Energy Procedia 40, 202-211. doi: 10.1016/j.egypro.2013.08.024.
Where Did the Water Go?: Boyle's Law and Pressurized Diaphragm Water Tanks
ERIC Educational Resources Information Center
Brimhall, James; Naga, Sundar
2007-01-01
Many homes use pressurized diaphragm tanks for storage of water pumped from an underground well. These tanks are very carefully constructed to have separate internal chambers for the storage of water and for the air that provides the pressure. One might expect that the amount of water available for use from, for example, a 50-gallon tank would be…
Cost-Effective, Ultra-Sensitive Groundwater Monitoring for Site Remediation and Management
2015-05-01
Example anion concentrations in groundwater used for feasibility studies. ................... 30 Table 5. Compounds screened in the laboratory for IS2...phase extraction ST storage tank SVOC semivolatile organic compound TCE trichloroethene TPH total petroleum hydrocarbon USEPA U.S. Environmental...Protection Agency UST underground storage tank V volt VOA volatile organic analysis VOC volatile organic compound Technical material
Weekly Natural Gas Storage Report - EIA
. Stocks were 804 Bcf less than last year at this time and 499 Bcf below the five-year average of 2,128 Bcf . At 1,629 Bcf, total working gas is within the five-year historical range. For information on sampling Underground Storage Compared with Five-Year Range Note: The shaded area indicates the range between the
A GIS Based 3D Online Decision Assistance System for Underground Energy Storage in Northern Germany
NASA Astrophysics Data System (ADS)
Nolde, M.; Schwanebeck, M.; Biniyaz, E.; Duttmann, R.
2014-12-01
We would like to present a GIS-based 3D online decision assistance system for underground energy storage. Its aim is to support the local land use planning authorities through pre-selection of possible sites for thermal, electrical and substantial underground energy storages. Since the extension of renewable energies has become legal requirement in Germany, the underground storing of superfluously produced green energy (such as during a heavy wind event) in the form of compressed air, gas or heated water has become increasingly important. However, the selection of suitable sites is a complex task. The assistance system uses data of geological features such as rock layers, salt caverns and faults enriched with attribute data such as rock porosity and permeability. This information is combined with surface data of the existing energy infrastructure, such as locations of wind and biogas stations, power line arrangement and cable capacity, and energy distribution stations. Furthermore, legal obligations such as protected areas on the surface and current underground mining permissions are used for the decision finding process. Not only the current situation but also prospective scenarios, such as expected growth in produced amount of energy are incorporated in the system. The decision process is carried out via the 'Analytic Hierarchy Process' (AHP) methodology of the 'Multi Object Decision Making' (MODM) approach. While the process itself is completely automated, the user has full control of the weighting of the different factors via the web interface. The system is implemented as an online 3D server GIS environment, with no software needed to be installed on the user side. The results are visualized as interactive 3d graphics. The implementation of the assistance system is based exclusively on free and open source software, and utilizes the 'Python' programming language in combination with current web technologies, such as 'HTML5', 'CSS3' and 'JavaScript'. It is developed at Kiel University for the federal state of Schleswig-Holstein in northern Germany. This work is part of project 'ANGUS+', lead by Prof. Dr. Sebastian Bauer and funded by the German Ministry for Education and Research (BMBF).
Oxidative stability of red palm oils blended chicken nuggets during frozen storage
NASA Astrophysics Data System (ADS)
Kamaruzaman, Nurkhuzaiah; Babji, Abdul Salam
2014-09-01
The effects of red palm oils known as Naturally Vitamin Rich Oil (NVRO) on the lipid stability of chicken nuggets were determined. Lipid oxidation was analyzed during frozen storage (-18 °C) for up to 4 months. Thiobarbituric acid (TBA) values and peroxide value (PV) for all samples chicken nuggets increased throughout 3 months of frozen storage and then start to decrease thereafter. Chicken nuggets formulated with NVRO, NVRO-100 and NVRO-50 showed lower TBA values and PV compared to the samples prepared with chicken fat. However, among NVRO, there were not significantly different for most of the months. It was concluded that the utilization of red palm oils in chicken nuggets significantly reduced the oxidation of lipid, which was indicated by the PV throughout 4 months of frozen storage.
Visualization of hydraulic connections using Borehole Array around LPG Underground Storage Cavern
NASA Astrophysics Data System (ADS)
Shimo, M.; Mashimo, H.; Maejima, T.; Aoki, K.
2006-12-01
This paper presents a systematic approach to visualize the hydraulic connections within the fractured rock mass around the underground LPG storage caverns using array of water injection boreholes. By taking advantage that water injection boreholes are located so as to cover the storage caverns, a complete sketch of hydraulic conditions around the caverns, such as locations of water conducting fractures, hydraulic conductivity and groundwater pressure can be obtained. Applicability of the proposed techniques have been tested in an on-going construction project operated by JOGMEC, Japan Oil, Gas and Metals National Corporation, at Namikata, Western part of Japan. Three 26m x 30m x 485m caverns, located at 150 - 200 m below the ground surface in a granitic rock, are under construction. By systematically monitoring the pressure responses between the neighboring boreholes during drilling of total 387 boreholes around the two propane caverns, a spatial profile of the hydraulic connections and hydraulic conductivity around the caverns has been successfully obtained. Locations of localized depressurized zones created during an arch excavation have been detected by monitoring pressure in each borehole after stopping water supply to that borehole temporarily. Measurement has been conducted using each one of the 302 boreholes, one at a time. Observation shows that there is a clear correlation between total pressure drop and pressure gradient versus time curve on semi-logarithmic plot, dH/log10t, as expected by the numerical prediction. Regions where dH/log10t is larger than a certain criteria, determined by a numerical simulation for flow around a cavern in a rock with uniform hydraulic conductivity, have been evaluated as a depressurized zone caused by insufficient water supply, possibly due to existence of the high permeable zones. Separate pore pressure measurement around the caverns also supports this interpretation that a low pressure is prevailing near the borehole where a large value of dH/log10t is obtained. As a countermeasure to avoid further depressurization, installation of additional water injection hole was conducted. The same observation was then repeated. It is recognized that dH/log10t has recovered above the criteria, showing that the local water balance has been improved. Finally it is concluded that the proposed rather simple but space encompassing observation is applicable to groundwater management during construction and also provides useful information for creating a hydrogeological model, considering a fracture network system, that will be used for the evaluation of the cavern performance as a storage tank.
Guimaraes, Wladmir B.; Falls, W. Fred; Caldwell, Andral W.; Ratliff, W. Hagan; Wellborn, John B.; Landmeyer, James E.
2012-01-01
Soil gas was assessed for contaminants in the building 310 underground storage tank area adjacent to the Dwight D. Eisenhower Army Medical Center at Ft. Gordon, Georgia, from October 2010 to September 2011. The assessment, which also included the detection of organic compounds in soil gas, provides environmental contamination data to Fort Gordon personnel pursuant to requirements of the Resource Conservation and Recovery Act Part B Hazardous Waste Permit process. The study was conducted by the U.S. Geological Survey, in cooperation with the U.S. Department of the Army Environmental and Natural Resources Management Office of the U.S. Army Signal Center and Fort Gordon. Soil-gas samplers were deployed below land surface at 37 locations in the building 310 underground storage tank area. Soil-gas samplers were deployed in a grid pattern near the storage tank area as well as downslope of the tank area in the direction of groundwater flow toward an unnamed tributary to Butler Creek. Total petroleum hydrocarbons were detected in 35 of the 37 soil-gas samplers at levels above the method detection level, and the combined mass of benzene, toluene, ethylbenzene, and total xylenes were detected above their detection levels in 8 of the 37 samplers. In addition, the combined masses of undecane, tridecane, and pentadecane were detected at or above their method detection levels in 9 of the 37 samplers. Other volatile organic compounds detected above their respective method detection levels were chloroform, 1,2,4-trimethylbenzene, and perchloroethylene. In addition, naphthalene, 2-methyl naphthalene, and 1,2,4-trimethylbenzene were detected below the method detection levels, but above the nondetection level.
Identification and characterization of high methane-emitting abandoned oil and gas wells
Kang, Mary; Christian, Shanna; Celia, Michael A.; Mauzerall, Denise L.; Bill, Markus; Miller, Alana R.; Chen, Yuheng; Conrad, Mark E.; Darrah, Thomas H.; Jackson, Robert B.
2016-01-01
Recent measurements of methane emissions from abandoned oil/gas wells show that these wells can be a substantial source of methane to the atmosphere, particularly from a small proportion of high-emitting wells. However, identifying high emitters remains a challenge. We couple 163 well measurements of methane flow rates; ethane, propane, and n-butane concentrations; isotopes of methane; and noble gas concentrations from 88 wells in Pennsylvania with synthesized data from historical documents, field investigations, and state databases. Using our databases, we (i) improve estimates of the number of abandoned wells in Pennsylvania; (ii) characterize key attributes that accompany high emitters, including depth, type, plugging status, and coal area designation; and (iii) estimate attribute-specific and overall methane emissions from abandoned wells. High emitters are best predicted as unplugged gas wells and plugged/vented gas wells in coal areas and appear to be unrelated to the presence of underground natural gas storage areas or unconventional oil/gas production. Repeat measurements over 2 years show that flow rates of high emitters are sustained through time. Our attribute-based methane emission data and our comprehensive estimate of 470,000–750,000 abandoned wells in Pennsylvania result in estimated state-wide emissions of 0.04–0.07 Mt (1012 g) CH4 per year. This estimate represents 5–8% of annual anthropogenic methane emissions in Pennsylvania. Our methodology combining new field measurements with data mining of previously unavailable well attributes and numbers of wells can be used to improve methane emission estimates and prioritize cost-effective mitigation strategies for Pennsylvania and beyond. PMID:27849603
Scheepers, P T J; Micka, V; Muzyka, V; Anzion, R; Dahmann, D; Poole, J; Bos, R P
2003-07-01
A field study was conducted in two mines in order to determine the most suitable strategy for ambient exposure assessment in the framework of a European study aimed at validation of biological monitoring approaches for diesel exhaust (BIOMODEM). Exposure to dust and particle-associated 1-nitropyrene (1-NP) was studied in 20 miners of black coal by the long wall method (Czech Republic) and in 20 workers in oil shale mining by the room and pillar method (Estonia). The study in the oil shale mine was extended to include 100 workers in a second phase (main study). In each mine half of the study population worked underground as drivers of diesel-powered trains (black coal) and excavators (oil shale). The other half consisted of workers occupied in various non-diesel production assignments. Exposure to diesel exhaust was studied by measurement of inhalable and respirable dust at fixed locations and by personal air sampling of respirable dust. The ratio of geometric mean inhalable to respirable dust concentration was approximately two to one. The underground/surface ratio of respirable dust concentrations measured at fixed locations and in the breathing zones of the workers was 2-fold or greater. Respirable dust was 2- to 3-fold higher in the breathing zone than at fixed sampling locations. The 1-NP content in these dust fractions was determined by gas chromatography-mass spectrometry/mass spectrometry and ranged from 0.003 to 42.2 ng/m(3) in the breathing zones of the workers. In mine dust no 1-NP was detected. In both mines 1-NP was observed to be primarily associated with respirable particles. The 1-NP concentrations were also higher underground than on the surface (2- to 3-fold in the coal mine and 10-fold or more in the oil shale mine). Concentrations of 1-NP in the breathing zones were also higher than at fixed sites (2.5-fold in the coal mine and 10-fold in the oil shale mine). For individual exposure assessment personal air sampling is preferred over air sampling at fixed sites. This study also suggests that particle-associated 1-NP much better reflects the ambient exposure to diesel exhaust particles than dust concentrations. Therefore, measurement of particle-associated 1-NP is preferred over measurement of dust concentrations by gravimetry, when linking ambient exposure to biomonitoring outcomes such as protein and DNA adducts and excretion of urinary metabolites of genotoxic substances.
NASA Astrophysics Data System (ADS)
Kühn, Michael; Li, Qi; Nakaten, Natalie, Christine; Kempka, Thomas
2017-04-01
Integration and further development of the energy supply system in China is a major challenge for the years to come. Part of the strategy is the implementation of a low carbon energy system based on carbon dioxide capture and storage (CCS). The innovative idea presented here is based on an extension of the power-to-gas-to-power (PGP) technology by establishing a closed carbon dioxide cycle [1]. Thereto, hydrogen generated from excess renewable energy is transformed into methane for combustion in a combined cycle gas power plant. To comply with the fluctuating energy demand, carbon dioxide produced during methane combustion and required for the methanation process as well as excess methane are temporarily stored in two underground reservoirs located close to each other [2]. Consequently, renewable energy generation units can be operated even if energy demand is below consumption, while stored energy can be fed into the grid as energy demand exceeds production [3]. We studied a show case for Xinjiang in China [4] to determine the energy demand of the entire process chain based on numerical computer simulations for the operation of the CO2 and CH4 storage reservoirs, and to ascertain the pressure regimes present in the storage formations during the injection and production phases of the annual cycle. [1] Streibel M., Nakaten N., Kempka T., Kühn M. (2013) Analysis of an integrated carbon cycle for storage of renewables. Energy Procedia 40, 202-211. doi: 10.1016/j.egypro.2013.08.024. [2] Kühn M., Streibel M., Nakaten N.C., Kempka T. (2014) Integrated Underground Gas Storage of CO2 and CH4 to Decarbonise the "Power-to-gas-to-gas-to-power" Technology. Energy Procedia 59, 9-15. doi: 10.1016/j.egypro.2014.10.342 [3] Kühn M., Nakaten N.C., Streibel M., Kempka T. (2014) CO2 Geological Storage and Utilization for a Carbon Neutral "Power-to-gas-to-power" Cycle to Even Out Fluctuations of Renewable Energy Provision. Energy Procedia 63, 8044-8049. doi: 10.1016/j.egypro.2014.11.841 [4] Li Q., Chen Z.A., Zhang J.T., Liu L.C., Li X.C., Jia L. (2016) Positioning and Revision of CCUS Technology Development in China. International Journal of Greenhouse Gas Control 46, 282-293. doi: 10.1016/j.ijggc.2015.02.024
DOE Office of Scientific and Technical Information (OSTI.GOV)
L. M. Dittmer
2006-09-27
The 100-B-20 waste site, located in the 100-BC-1 Operable Unit of the Hanford Site, consisted of an underground oil tank that once serviced the 1716-B Maintenance Garage. The selected action for the 100-B-20 waste site involved removal of the oil tanks and their contents and demonstrating through confirmatory sampling that all cleanup goals have been met. In accordance with this evaluation, a reclassification status of interim closed out has been determined. The results demonstrate that the site will support future unrestricted land uses that can be represented by a rural-residential scenario. These results also show that residual concentrations support unrestrictedmore » future use of shallow zone soil and that contaminant levels remaining in the soil are protective of groundwater and the Columbia River.« less
NASA Astrophysics Data System (ADS)
Murni, V. W.; Saepudin, E.; Cahyana, A. H.; Rahayu, D. U. C.; Hastuti, L. T.; Haib, J.
2017-07-01
The research about post-harvested clove is still limited especially in Indonesia, as the biggest producer of clove in the world. The present study was aimed to investigate the effect of drying process and storage on the composition of essential oil of Indonesian clove originated from Toli-Toli. The essential oil of fresh and dried clove was obtained by steam distillation and the composition of the oil was analyzed by gas chromatography-mass spectrometry (GC-MS). In all of the clove oil samples, eugenol was the major component, followed by caryophyllene and acetyleugenol. The drying method used was oven drying at 50°C until clove's moisture content reaches 13±1%. During the drying process, the content of phenylpropanoids such as eugenol, isoeugenol, and chavicol increased, while esters and monoterpenes decreased. The composition of clove oil was studied from dried clove after oven drying, then stored in the laboratory at room temperature for 4 months. There was slightly change on clove oil composition after 4 months of storage. The content of major components of clove like eugenol was higher while acetyleugenol was lower after 4 months of storage.
NASA Astrophysics Data System (ADS)
Kennedy, Lynn W.; Schneider, Kenneth D.
1990-07-01
A large-sclae test of the detonation of 20,000 kilograms of high explosive inside a shallow underground tunnel/chamber complex, simulating an ammunition storage magazine, was carried out in August, 1988, at the Naval Weapons Center, China Lake, California. The test was jointly sponsored by the U.S. Department of Defense Explosives Safety Board; the Safety Services Organisation of the Ministry of Defence, United Kingdom; and the Norwegian Defence Construction Service. The overall objective of the test was to determine the hazardous effects (debris, airblast, and ground motion) produced in this configuration. Actual storage magazines have considerably more overburden and are expected to contain and accidental detonation. The test configuration, on the other hand, was expected to rupture, and to scatter a significant amount of rocks, dirt and debris. Among the observations and measurements made in this test was study of airblast propagation within the storage chamber, in the access tunnel, and outside, on the tunnel ramp, prior to overburden venting. The results of these observations are being used to evaluate and validate current quantity-distance standards for the underground storage of munitions near inabited structures. As part of the prediction effort for this test, to assist with transducer ranging in the access tunnel and with post-test interpretation of the results, S-CUBED was asked to perform two-dimensional inviscid hydrodynamic code calculations of the explosive detonation and subsequent blastwave propagation in the interior chamber and access tunnel. This was accomplished using the S-CUBED Hydrodynamic Advanced Research Code (SHARC). In this paper, details of the calculations configuration will be presented. These will be compared to the actual as-built internal configuration of the tunnel/chamber complex. Results from the calculations, including contour plots and airblast waveforms, will be shown. The latter will be compared with experimental records obtained at several points within the tunnel.
Clean Water State Revolving Fund (CWSRF): Contaminated Sites
Communities can use the CWSRF to address the water quality aspects of site assessment and cleanup of brownfields, Superfund sites, and sites of current or former aboveground or underground storage tanks.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Frailey, Scott M.; Krapac, Ivan G.; Damico, James R.
2012-03-30
The Midwest Geological Sequestration Consortium (MGSC) carried out a small-scale carbon dioxide (CO 2) injection test in a sandstone within the Clore Formation (Mississippian System, Chesterian Series) in order to gauge the large-scale CO 2 storage that might be realized from enhanced oil recovery (EOR) of mature Illinois Basin oil fields via miscible liquid CO 2 flooding.
Hemery, Youna M; Fontan, Laura; Moench-Pfanner, Regina; Laillou, Arnaud; Berger, Jacques; Renaud, Cécile; Avallone, Sylvie
2015-10-01
Food fortification is implemented to address vitamins A and D deficiencies in numerous countries. The stability of vitamins A and D3 was assessed during a two-month period reproducing the usual oil storage conditions before sale to consumers. Soybean oils with different oxidative status and vitamin E contents were stored in the dark, semi-dark, or exposed to natural light. Lipid peroxidation took place after 3 weeks of storage in dark conditions. After 2 months, the vitamin A and D3 losses reached 60-68% and 61-68%, respectively, for oils exposed to natural light, and 32-39% and 24-44% in semi-dark conditions. The determining factors of vitamin A and D3 losses were (in decreasing order) the storage time, the exposure to light and the oxidative status of the oil, whereas vitamin E content had a protective role. Improving these parameters is thus essential to make vitamins A and D fortification in oils more efficient. Copyright © 2015. Published by Elsevier Ltd.
Toda, Kei; Ebisu, Yuki; Hirota, Kazutoshi; Ohira, Shin-Ichi
2012-09-05
Underground fluids are important natural sources of drinking water, geothermal energy, and oil-based fuels. To facilitate the surveying of such underground fluids, a novel microchannel extraction device was investigated for in-line continuous analysis and flow injection analysis of sulfide levels in water and in oil. Of the four designs investigated, the honeycomb-patterned microchannel extraction (HMCE) device was found to offer the most effective liquid-liquid extraction. In the HMCE device, a thin silicone membrane was sandwiched between two polydimethylsiloxane plates in which honeycomb-patterned microchannels had been fabricated. The identical patterns on the two plates were accurately aligned. The extracted sulfide was detected by quenching monitoring of fluorescein mercuric acetate (FMA). The sulfide extraction efficiencies from water and oil samples of the HMCE device and of three other designs (two annular and one rectangular channel) were examined theoretically and experimentally. The best performance was obtained with the HMCE device because of its thin sample layer (small diffusion distance) and large interface area. Quantitative extraction from both water and oil could be obtained using the HMCE device. The estimated limit of detection for continuous monitoring was 0.05 μM, and sulfide concentrations in the range of 0.15-10 μM could be determined when the acceptor was 5 μM FMA alkaline solution. The method was applied to natural water analysis using flow injection mode, and the data agreed with those obtained using headspace gas chromatography-flame photometric detection. The analysis of hydrogen sulfide levels in prepared oil samples was also performed. The proposed device is expected to be used for real time survey of oil wells and groundwater wells. Copyright © 2012 Elsevier B.V. All rights reserved.
Preservation of chicken breast meat treated with thyme and balm essential oils.
Fratianni, Florinda; De Martino, Laura; Melone, Antonio; De Feo, Vincenzo; Coppola, Raffaele; Nazzaro, Filomena
2010-10-01
The present study evaluated the effects of thyme and balm essential oils on the 3-wk storage of fresh chicken breast meat at 4 °C. Thyme and, to a lesser extent, balm essential oils reduced DPPH (2,2-diphenyl-1-picrylhydrazyl) radical formation in the meat (25% to 30% and 20%, respectively). Treatment with the 2 essential oils also limited lipid peroxidation and the deterioration of sarcoplasmic proteins, helping to preserve the meat even after 2 wk of storage. Thyme and balm essential oils decreased the natural microflora present in the meat; total microbial content decreased down to 50% in comparison to the control samples. In addition, a clear effect on lactic acid bacterial growth was recorded. Balm essential oil significantly limited the growth of Salmonella sp., whereas thyme essential oil effectively inhibited the growth of Escherichia coli. Our data demonstrate that these 2 essential oils effectively reduced deteriorative processes in chicken meat and extended the shelf life of this fresh product. Practical Application: The essential oils of thyme and balm can protect the chicken meat from decomposition during the storage time.
30 CFR 57.4130 - Surface electric substations and liquid storage facilities.
Code of Federal Regulations, 2010 CFR
2010-07-01
... LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and Control Prohibitions/precautions/housekeeping § 57.4130 Surface electric...
Underground Gas Storage Facility Safety Act of 2013
Sen. Roberts, Pat [R-KS
2013-04-18
Senate - 04/18/2013 Read twice and referred to the Committee on Commerce, Science, and Transportation. (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:
Underground Gas Storage Facility Safety Act of 2011
Sen. Roberts, Pat [R-KS
2011-11-30
Senate - 11/30/2011 Read twice and referred to the Committee on Commerce, Science, and Transportation. (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:
NASA Astrophysics Data System (ADS)
Ugalde, Arantza; Gaite, Beatriz; Villaseñor, Antonio
2016-04-01
During September 2013, the injection of the base gas in a depleted oil reservoir used as an underground natural gas storage (CASTOR) caused a sudden seismic activity increase in the eastern coast of Spain. As a result, a compact cluster of more than 550 earthquakes with magnitudes mbLg > 0.7 were located in the shallow offshore area of the Gulf of Valencia during two months. The strongest event, having a magnitude of Mw=4.2, was followed by two Mw=4.1 events the day after and took place once the gas injection activities had finished. Using the seismic data recorded by permanent stations at more than 25 km from the injection well, we applied coda wave interferometry to monitor changes in seismic velocity structure between similar earthquakes. Then we solved for a continuous function of velocity changes with time by combining observations from all the closely located earthquake sources. The rate of repeating events allowed measurements of relative velocity variations for about 30 days on a daily scale. To extend the analysis in time, we also processed the continuous data using the autocorrelation of band-pass filtered ambient seismic noise. A 10-day average was required to achieve a sufficient signal-to-noise ratio in the 0.2-0.5 Hz and 0.5-1 Hz frequency bands. We quantified the time lags between two traces in the frequency and time domains by means of the Moving Window Cross Spectral Analysis and a Dynamic Time Warping technique, respectively. Injection of fluids in geologic formations causes variations in seismic velocities associated to changes in fluid saturation, increase in pore pressure or opening or enlargement of cracks due to the injection process. Time delays associated with stress changes caused by moderate to large earthquakes have also been established. In this work, we found no velocity changes during the gas injection period nor on the occasion of the Mw 4.2 earthquake. The sensitivity of the method is dependent on the seismic network geometry and the lateral extent of the velocity anomaly. With the given network configuration we conclude that any temporal changes in seismic velocities in the CASTOR gas storage area must be smaller than 0.05%.
Characterization of Gas Transport Properties of Fractured Rocks By Borehole and Chamber Tests.
NASA Astrophysics Data System (ADS)
Shimo, M.; Shimaya, S.; Maejima, T.
2014-12-01
Gas transport characteristics of fractured rocks is a great concern to variety of engineering applications such as underground storage of LPG, nuclear waste disposal, CCS and gas flooding in the oil field. Besides absolute permeability, relative permeability and capillary pressure as a function of water saturation have direct influences to the results of two phase flow simulation. However, number of the reported gas flow tests for fractured rocks are limited, therefore, the applicability of the conventional two-phase flow functions used for porous media, such as Mualem-van Genuchten model, to prediction of the gas transport in the fractured rock mass are not well understood. The authors conducted the two types of in-situ tests, with different scales, a borehole gas-injection test and a chamber gas-injection test in fractured granitic rock. These tests were conducted in the Cretaceous granitic rocks at the Namikata underground LPG storage cavern construction site in Ehime Prefecture in Japan, preceding to the cavern scale gas-tightness test. A borehole injection test was conducted using vertical and sub-vertical boreholes drilled from the water injection tunnel nearly at the depth of the top of the cavern, EL-150m. A new type downhole gas injection equipment that is capable to create a small 'cavern' within a borehole was developed. After performing a series of preliminary tests to investigate the hydraulic conductivity and gas-tightness, i.e. threshold pressure, gas injection tests were conducted under different gas pressure. Fig.1 shows an example of the test results From a chamber test using a air pressurizing chamber with volume of approximately166m3, the gas-tightness was confirmed within the uncertainty of 22Pa under the storage pressure of 0.7MPa, however, significant air leakage occurred possibly through an open fracture intersecting the chamber just after cavern pressure exceeds the initial hydrostatic pressure at the ceiling level of the chamber. Anomalies were detected in the data of the pore pressure as well as AE monitoring around the chamber. Results from the above two tests were simulated using a multi-phase transport simulator, TOUGH2, developed at Lawrence Berkeley National Laboratory. Fig.2 shows the model and an example of the simulation.
Hachicha Hbaieb, Rim; Kotti, Faten; Gargouri, Mohamed; Msallem, Monji; Vichi, Stefania
2016-07-15
The distinctive aroma of virgin olive oil is mainly attributed to its volatile profile including components responsible for positive attributes and others for sensory defects resulting from chemical oxidation and exogenous enzymes. For this reason, the evolution of volatile compounds from Chétoui and Arbequina virgin olive oils during olive ripening and storage (at 4 and 25 °C during 4 weeks) was investigated. The profile of volatile phenols during olive storage was also studied. Quantitative differences in the volatile compounds during olive storage at 4 and 25 °C according to olive cultivar was determined. Concerning the volatile phenols, the Arbequina olives were the most affected by high storage temperature, as the formation of these compounds, especially 4-ethyl and 4-vinyl derivatives of phenol and guaiacol were more noticeable in Arbequina oils extracted from stored fruits at 25 °C. Copyright © 2016 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
McDermott, William F.
1979-12-01
The major activities at OOSI's Logan Wash site during the quarter were: driving the access drifts towards the underground locations for Retorts 7 and 8; manway raise boring; constructing the change house; rubbling the first lift of Mini-Retort (MR)1; preparing the Mini-Retorts for tracer testing; coring of Retort 3E; and beginning the DOE instrumentation program.
ERIC Educational Resources Information Center
American School and University, 1981
1981-01-01
Underground geothermal water from an artesian well supplies heat for rural Haakon School District in Philip (South Dakota). The same water is then piped to the downtown business district a few blocks away and sold as fuel to participating merchants. (Author/MLF)
Oil-in-Ice Demonstration 4: Quick Look Report
2016-11-01
infrastructure, increase the potential for accidental discharges of oil . To address these concerns, responders in the northern climate regions are...It is suggested that improvements to the new equipment can be used on a buoy tender in Alaska for an oil spill response in the Bering Straits or off...to be simplified for better storage in the ship’s hold, easy assembly and deployment. Suggestions such as using the hold for oil storage may be
Nabavizadeh, Mohammadreza; Abbaszadegan, Abbas; Khodabakhsi, Afrooz; Ahzan, Shamseddin; Mehrabani, Davood
2018-03-01
Researchers always seek a new storage medium for avulsed teeth. Castor oil is a vegetable oil with several advantages such as antimicrobial and antioxidant properties, low toxicity, and glutathione preservation capability, low cost, and high availability. The purpose of this study was to evaluate and compare the capacity of castor oil as a new storage medium in preserving the viability of periodontal ligament (PDL) cells compared to Hank's balanced salt solution (HBSS) and milk. Forty freshly extracted human teeth were divided into 3 experimental and 2 control groups. The experimental teeth were stored dry for 30 min and then immersed for 45 min in one of the following media; castor oil, HBSS, and milk. The positive and negative control groups were exposed to 0 min and 2 h of dry time respectively with no immersion in any storage medium. The teeth were then treated with dispase grade II and collagenase and the number of viable PDL cells were counted. Data were analyzed using Kruskal- Wallis test. The percentage of viable cells treated with castor oil, HBSS and milk counted immediately after removal from these media were 46.93, 51.02 and 55.10 % respectively. The statistical analysis revealed that the value for castor oil was significantly lower than HBSS and milk ( p > 0.05). Within the parameters of this study, it appears that castor oil cannot be served as an ideal medium for storage of avulsed tooth. More investigations under in vivo conditions are required to justify the results of this study.
NASA Astrophysics Data System (ADS)
Hall, Kristyn Ann
The rising carbon dioxide emissions contributing to climate change has lead to the examination of potential ways to mitigate the environmental impact. One such method is through the geological sequestration of carbon (CCS). Although there are several different forms of geological sequestration (i.e. Saline Aquifers, Oil and Gas Reservoirs, Unminable Coal Seams) the current projects are just initiating the large scale-testing phase. The lead entry point into CCS projects is to combine the sequestration with enhanced oil recovery (EOR) due to the improved economic model as a result of the oil recovery and the pre-existing knowledge of the geological structures. The potential scope of CCS-EOR projects throughout the continental United States in terms of a systematic examination of individual reservoir storage potential has not been examined. Instead the majority of the research completed has centered on either estimating the total United States storage potential or the potential of a single specific reservoir. The purpose of this paper is to examine the relationship between oil recovery, carbon dioxide storage and cost during CCS-EOR. The characteristics of the oil and gas reservoirs examined in this study from the Nehring Oil and Gas Database were used in the CCS-EOR model developed by Sean McCoy to estimate the lifting and storage costs of the different reservoirs throughout the continental United States. This allows for an examination of both technical and financial viability of CCS-EOR as an intermediate step for future CCS projects in other geological formations. One option for mitigating climate change is to store industrial CO2 emissions in geologic reservoirs as part of a process known as carbon capture and storage (CCS). There is general consensus that large-scale deployment of CCS would best be initiated by combining geologic sequestration with enhanced oil recovery (EOR), which can use CO2 to improve production from declining oil fields. Revenues from the produced oil could help offset the current high costs of CCS. The cumulative potential of CCS-EOR in the continental U.S. has been evaluated in terms of both CO2 storage capacity and additional oil production. This thesis examines the same potential, but on a reservoir-by-reservoir basis. Reservoir properties from the Nehring Oil and Gas Database are used as inputs to a CCS-EOR model developed by McCoy (YR) to estimate the storage capacity, oil production and CCS-EOR costs for over 10,000 oil reservoirs located throughout the continental United States. We find that 86% of the reservoirs could store ≤1 y or CO2 emissions from a single 500 MW coal-fired power plant (i.e., 3 Mtons CO2). Less than 1% of the reservoirs, on the other hand, appear capable of storing ≥30 y of CO2 emissions from a 500 MW plan. But these larger reservoirs are also estimated to contain 48% of the predicted additional oil that could be produced through CCS-EOR. The McCoy model also predicts that the reservoirs will on average produce 4.5 bbl of oil for each ton of sequestered CO2, a ratio known as the utilization factor. This utilization factor is 1.5 times higher that arrived at by the U.S. Department of Energy, and leads to a cumulative production of oil for all the reservoirs examined of ˜183 billion barrels along with a cumulative storage capacity of 41 Mtons CO2. This is equivalent to 26.5 y of current oil consumption by the nation, and 8.5 y of current coal plant emissions.
A tiered approach to distinguish sources of gasoline and diesel spills.
Xiong, Wenhui; Bernesky, Ryan; Bechard, Robert; Michaud, Guy; Lang, Jeremy
2014-07-15
Approximately 11% and 25% of annual Canadian oil spill accidents are gasoline and diesel spills, respectively. Gasoline and diesel spills are a challenge to conventional environmental forensic techniques because refinery processes remove most of the higher molecular weight biomarkers. This study presents a tiered environmental forensics strategy that includes such information as site operational history, geology/hydrogeology, GC/FID pre-screening, volatile GC/MS, semi-volatile GC/MS, and GC/MS selected ion monitoring (SIM) chromatograms for fingerprinting of gasoline and diesel spills. GC/FID pre-screening analysis identified the presence of two individual gasoline and diesel plumes at a fuel service station (study site). The gasoline plume is present between the upgradient fuel underground storage tanks (USTs) and the downgradient diesel plume, suggesting that the diesel impacts to groundwater may not be originated from the current UST leakage. Similar distribution of C3-alkylbenzenes (the most stable chemicals in gasoline) and the consistent diagnostic ratios of the analyte pairs with similar solubility indicate that the source for the dissolved gasoline constituents in the gasoline impacted zone likely originated from a gasoline leakage from the current USTs on the study site. In the diesel impacted zone, the distinct distribution and diagnostic ratios of sesquiterpanes (biomarkers for diesel) and alkylated PAHs confirm that the diesel plume originate from different crude oil sources than the current USTs. Copyright © 2014 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Gilliss, Thomas; MAJORANA DEMONSTRATOR Collaboration
2017-01-01
The MAJORANA DEMONSTRATOR advances toward measurements of the neutrinoless double-beta decay of 76Ge. Detectors employed in the DEMONSTRATOR are subject to cosmogenic spallation during production and processing, resulting in activation of certain long-lived radioisotopes. Activation of these cosmogenic isotopes is mitigated by shielded storage of detectors and through underground operation of the DEMONSTRATOR at the 4850 ft level of the Sanford Underground Research Facility. In this work, we explore the appearance and reduction of cosmogenic contributions to the DEMONSTRATOR background spectrum. This work is supported by the U.S. Department of Energy, Office of Science, Office of Nuclear Physics, the Particle Astrophysics and Nuclear Physics Programs of the National Science Foundation, and the Sanford Underground Research Facility.
1. Keeper's house, oil house, light tower and storage building, ...
1. Keeper's house, oil house, light tower and storage building, view northeast, south or southwest sides - Petit Manan Light Station, 2.5 miles south of Petit Manan Point, Milbridge, Washington County, ME
New insights into the early steps of oil body mobilization during pollen germination
Castro, Antonio Jesús
2013-01-01
In some plants, pollen grains accumulate storage lipids that serve as energy supply during germination. Here, three enzymes involved in early steps of oil body mobilization in the male gametophyte were functionally characterized for the first time. The effect of extracellular sugars on pollen performance and oil body dynamics was also analysed. Olive pollen oil bodies showed phospholipase A, lipase, and lipoxygenase activities on their surface. Enzyme activity levels increased during germination with a maximum after 3h. Removal of extracellular sugars from the germination medium did not affect pollen performance but increased enzyme activity rates and sped up oil body mobilization. Inhibitors seriously hampered pollen germination and pollen tube growth, leading to a characteristic accumulation of oil bodies in the germinative aperture. It can be concluded that storage lipids are sufficient for proper olive pollen germination. A lipase and a lipoxygenase are likely involved in oil body mobilization. Extracellular sugars may modulate their function, while a phospholipase A may promote their access to the storage lipids. PMID:23132905
The mathematical model accuracy estimation of the oil storage tank foundation soil moistening
NASA Astrophysics Data System (ADS)
Gildebrandt, M. I.; Ivanov, R. N.; Gruzin, AV; Antropova, L. B.; Kononov, S. A.
2018-04-01
The oil storage tanks foundations preparation technologies improvement is the relevant objective which achievement will make possible to reduce the material costs and spent time for the foundation preparing while providing the required operational reliability. The laboratory research revealed the nature of sandy soil layer watering with a given amount of water. The obtained data made possible developing the sandy soil layer moistening mathematical model. The performed estimation of the oil storage tank foundation soil moistening mathematical model accuracy showed the experimental and theoretical results acceptable convergence.
40 CFR 282.93 - Texas State-Administered Program.
Code of Federal Regulations, 2010 CFR
2010-07-01
... provisions will be added to this subpart and notice of any change will be published in the Federal Register... Underground Storage Tank Program, Texas Natural Resource Conservation Commission, P.O. Box 13087, Austin, TX...
Green Remediation Best Management Practices: Sites with Leaking Underground Storage Tank Systems
The U.S. Environmental Protection Agency (EPA) Principles for Greener Cleanups outline the Agency's policy for evaluating and minimizing the environmental 'footprint' of activities undertaken when cleaning up a contaminated site.
Class A and Class B UST Operator Exams
Learn about exams developed by EPA to help underground storage tank system owners and operators in Indian country meet the 2015 federal UST regulation requirement that designated operators demonstrate knowledge and pass an exam.
1. MAGAZINE COMPLEX, O, P, AND Q. MAGAZINE P IN ...
1. MAGAZINE COMPLEX, O, P, AND Q. MAGAZINE P IN BACKGROUND, LOOKING NORTHEAST. - NIKE Missile Base C-84, Underground Storage Magazines & Launcher-Loader Assemblies, Easternmost portion of launch area, Barrington, Cook County, IL
2017-01-01
Highlights activities, events, and analyses associated with the natural gas industry. Volume and price data are presented each month for natural gas production, distribution, consumption, and interstate pipeline activities. Producer related activities and underground storage data are also reported.
Persistency of larvicidal effects of plant oil extracts under different storage conditions.
Amer, Abdelkrim; Mehlhorn, Heinz
2006-09-01
The persistency of larvicidal effects of 13 oils (camphor, thyme, amyris, lemon, cedarwood, frankincense, dill, myrtle, juniper, black pepper, verbena, helichrysum, and sandalwood) was examined by storage of 50-ppm solutions under different conditions (open, closed, in the light, and in the dark) for 1 month after the preparation of the solutions. The stored solutions were tested against Aedes aegypti larvae for four times during the storage period. Some oils under some conditions stayed effective until the last test, while some solutions had lost their toxicity during a short time after preparation. Thus, the mode of storage is absolutely important for the larvicidal effects. The fresh preparations were always the best.
40 CFR 144.34 - Emergency permits.
Code of Federal Regulations, 2010 CFR
2010-07-01
....34 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) UNDERGROUND INJECTION CONTROL PROGRAM Authorization by Permit § 144.34 Emergency permits. (a) Coverage... unless a temporary emergency permit is granted; or (2) A substantial and irretrievable loss of oil or gas...
Pandey, Abhay K; Sonker, Nivedita; Singh, Pooja
2016-04-01
During mycofloral analysis of green gram (Vigna radiata (L.) R. Wilczek) seed samples taken from different grocery stores by agar and standard blotter paper methods, 5 fungal species were identified, of which Aspergillus flavus exhibited higher relative frequency (75.20% to 80.60%) and was found to produce aflatoxin B1 . On screening of 11 plant essential oils against this mycotoxigenic fungi, Lippia alba essential oil was found to be most effective and showed absolute inhibition of mycelia growth at 0.28 μL/mL. The oil of L. alba was fungistatic and fungicidal at 0.14 and 0.28 μL/mL, respectively. Oil had broad range of fungitoxicity at its MIC value and was absolutely inhibited the AFB1 production level at 2.0 μL/mL. Chemical analysis of this oil revealed geranial (36.9%) and neral (29.3%) as major components followed by myrcene (18.6%). Application of a dose of 80 μL/0.25 L air of Lippia oil in the storage system significantly inhibited the fungal proliferation and aflatoxin production without affecting the seed germination rate. By the virtue of fungicidal, antiaflatoxigenic nature and potent efficacy in storage food system, L. alba oil can be commercialized as botanical fungicide for the protection of green gram seeds during storage. © 2016 Institute of Food Technologists®
3D Modelling of Seismically Active Parts of Underground Faults via Seismic Data Mining
NASA Astrophysics Data System (ADS)
Frantzeskakis, Theofanis; Konstantaras, Anthony
2015-04-01
During the last few years rapid steps have been taken towards drilling for oil in the western Mediterranean sea. Since most of the countries in the region benefit mainly from tourism and considering that the Mediterranean is a closed sea only replenishing its water once every ninety years careful measures are being taken to ensure safe drilling. In that concept this research work attempts to derive a three dimensional model of the seismically active parts of the underlying underground faults in areas of petroleum interest. For that purpose seismic spatio-temporal clustering has been applied to seismic data to identify potential distinct seismic regions in the area of interest. Results have been coalesced with two dimensional maps of underground faults from past surveys and seismic epicentres, having followed careful reallocation processing, have been used to provide information regarding the vertical extent of multiple underground faults in the region of interest. The end product is a three dimensional map of the possible underground location and extent of the seismically active parts of underground faults. Indexing terms: underground faults modelling, seismic data mining, 3D visualisation, active seismic source mapping, seismic hazard evaluation, dangerous phenomena modelling Acknowledgment This research work is supported by the ESPA Operational Programme, Education and Life Long Learning, Students Practical Placement Initiative. References [1] Alves, T.M., Kokinou, E. and Zodiatis, G.: 'A three-step model to assess shoreline and offshore susceptibility to oil spills: The South Aegean (Crete) as an analogue for confined marine basins', Marine Pollution Bulletin, In Press, 2014 [2] Ciappa, A., Costabile, S.: 'Oil spill hazard assessment using a reverse trajectory method for the Egadi marine protected area (Central Mediterranean Sea)', Marine Pollution Bulletin, vol. 84 (1-2), pp. 44-55, 2014 [3] Ganas, A., Karastathis, V., Moshou, A., Valkaniotis, S., Mouzakiotis, E. and Papathanassiou, G.: 'Aftershock relocation and frequency-size distribution, stress inversion and seismotectonic setting of the 7 August 2013 M=5.4 earthquake in Kallidromon Mountain, central Greece', Tectonophysics, vol. 617, pp. 101-113, 2014 [4] Maravelakis, E., Bilalis, N., Mantzorou, I., Konstantaras, A. and Antoniadis, A.: '3D modelling of the oldest olive tree of the world', International Journal Of Computational Engineering Research, vol. 2 (2), pp. 340-347, 2012 [5] Konstantaras, A., Katsifarakis, E, Maravelakis, E, Skounakis, E, Kokkinos, E. and Karapidakis, E.: 'Intelligent spatial-clustering of seismicity in the vicinity of the Hellenic seismic arc', Earth Science Research, vol. 1 (2), pp. 1- 10, 2012 [6] Georgoulas, G., Konstantaras, A., Katsifarakis, E., Stylios, C., Maravelakis, E and Vachtsevanos, G.: 'Seismic-mass" density-based algorithm for spatio-temporal clustering', Expert Systems with Applications, vol. 40 (10), pp. 4183-4189, 2013 [7] Konstantaras, A.: 'Classification of Distinct Seismic Regions and Regional Temporal Modelling of Seismicity in the Vicinity of the Hellenic Seismic Arc', Selected Topics in Applied Earth Observations and Remote Sensing, IEEE Journal of', vol. 99, pp. 1-7, 2013
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jean-Philippe Nicot; Renaud Bouroullec; Hugo Castellanos
2006-06-30
Underground carbon storage may become one of the solutions to address global warming. However, to have an impact, carbon storage must be done at a much larger scale than current CO{sub 2} injection operations for enhanced oil recovery. It must also include injection into saline aquifers. An important characteristic of CO{sub 2} is its strong buoyancy--storage must be guaranteed to be sufficiently permanent to satisfy the very reason that CO{sub 2} is injected. This long-term aspect (hundreds to thousands of years) is not currently captured in legislation, even if the U.S. has a relatively well-developed regulatory framework to handle carbonmore » storage, especially in the operational short term. This report proposes a hierarchical approach to permitting in which the State/Federal Government is responsible for developing regional assessments, ranking potential sites (''General Permit'') and lessening the applicant's burden if the general area of the chosen site has been ranked more favorably. The general permit would involve determining in the regional sense structural (closed structures), stratigraphic (heterogeneity), and petrophysical (flow parameters such as residual saturation) controls on the long-term fate of geologically sequestered CO{sub 2}. The state-sponsored regional studies and the subsequent local study performed by the applicant will address the long-term risk of the particular site. It is felt that a performance-based approach rather than a prescriptive approach is the most appropriate framework in which to address public concerns. However, operational issues for each well (equivalent to the current underground injection control-UIC-program) could follow regulations currently in place. Area ranking will include an understanding of trapping modes. Capillary (due to residual saturation) and structural (due to local geological configuration) trappings are two of the four mechanisms (the other two are solubility and mineral trappings), which are the most relevant to the time scale of interest. The most likely pathways for leakage, if any, are wells and faults. We favor a defense-in-depth approach, in which storage permanence does not rely upon a primary seal only but assumes that any leak can be contained by geologic processes before impacting mineral resources, fresh ground water, or ground surface. We examined the Texas Gulf Coast as an example of an attractive target for carbon storage. Stacked sand-shale layers provide large potential storage volumes and defense-in-depth leakage protection. In the Texas Gulf Coast, the best way to achieve this goal is to establish the primary injection level below the total depth of most wells (>2,400 m-8,000 ft). In addition, most faults, particularly growth faults, present at the primary injection level do not reach the surface. A potential methodology, which includes an integrated approach comprising the whole chain of potential events from leakage from the primary site to atmospheric impacts, is also presented. It could be followed by the State/Federal Government, as well as by the operators.« less
Microbial Life in an Underground Gas Storage Reservoir
NASA Astrophysics Data System (ADS)
Bombach, Petra; van Almsick, Tobias; Richnow, Hans H.; Zenner, Matthias; Krüger, Martin
2015-04-01
While underground gas storage is technically well established for decades, the presence and activity of microorganisms in underground gas reservoirs have still hardly been explored today. Microbial life in underground gas reservoirs is controlled by moderate to high temperatures, elevated pressures, the availability of essential inorganic nutrients, and the availability of appropriate chemical energy sources. Microbial activity may affect the geochemical conditions and the gas composition in an underground reservoir by selective removal of anorganic and organic components from the stored gas and the formation water as well as by generation of metabolic products. From an economic point of view, microbial activities can lead to a loss of stored gas accompanied by a pressure decline in the reservoir, damage of technical equipment by biocorrosion, clogging processes through precipitates and biomass accumulation, and reservoir souring due to a deterioration of the gas quality. We present here results from molecular and cultivation-based methods to characterize microbial communities inhabiting a porous rock gas storage reservoir located in Southern Germany. Four reservoir water samples were obtained from three different geological horizons characterized by an ambient reservoir temperature of about 45 °C and an ambient reservoir pressure of about 92 bar at the time of sampling. A complementary water sample was taken at a water production well completed in a respective horizon but located outside the gas storage reservoir. Microbial community analysis by Illumina Sequencing of bacterial and archaeal 16S rRNA genes indicated the presence of phylogenetically diverse microbial communities of high compositional heterogeneity. In three out of four samples originating from the reservoir, the majority of bacterial sequences affiliated with members of the genera Eubacterium, Acetobacterium and Sporobacterium within Clostridiales, known for their fermenting capabilities. In contrast, bacteria belonging to Enterobacteriaceae were the most frequently encountered species in the sample from the water production well. Furthermore, bacterial sequences belonging to thermophiles within the family Thermotogaceae were found in all samples investigated. Archaeal community analysis revealed the dominance of methanogens clustering with members of Methanosarcinaceae, Methanomicrobiaceae and Methanobacteriaceae in three reservoir samples and the sample from the water production well. Cultivations of water samples under an atmosphere of storage gas blended by hydrogen as electron source at in situ-like conditions (45°C, 92 bar, p(H2) = 6 bar) revealed that hydrogen was quickly consumed in all laboratory microcosms with reservoir samples. Quantitative PCR analysis of the gene encoding for methyl-coenzyme M reductase (mcrA) along with reaction educt and product analyses suggested that methanogenesis was primarily responsible for hydrogen consumption during the experiments. While it is currently in question whether or not the laboratory data can be upscaled to actual reservoir conditions, they may allude to fermenting and thermophilic bacteria playing an important role for the investigated reservoir microbiology and also indicate potential stimulation of hydrogenotrophic methanogens if hydrogen would be introduced into the reservoir.
Impact of savanna conversion to oil palm plantations on C stocks dynamics and soil fertility
NASA Astrophysics Data System (ADS)
Quezada, Juan Carlos; Guillaume, Thomas; Buttler, Alexandre; Ruegg, Johanna
2017-04-01
Large-scale expansion of oil palm cultivation on forested land in South-East Asia during the last decades lead to high negative environmental impacts. Because rainforests store high amount of C, their conversion to oil palm plantations results in large net CO2 emissions. Oil palm cultivation in tropical ecosystems such as savanna that store less C than forests is seen as an alternative to reduce greenhouse gas emissions of future oil palm development. While this option is more and more frequently mentioned, few data are available on the effective gain in C storage. Furthermore negative impact on soil organic carbon and soil fertility could offset gains of C storage in oil palm biomass. Here, we present results on aboveground and belowground C stocks and soil nutrient dynamics over a full rotation cycle of oil palm plantations established on tropical savanna grasslands. Three natural savanna grasslands as reference sites and 9 oil palm plantations ranging from two to twenty-seven years old were selected in the Llanos in Colombia. Oxisols were sampled down to 70 cm in each management zones of oil palm plantations (weeded circle, interrow, frond piles and harvesting path). Taking advantages of a shift from C4 to C3 vegetation, we quantified savanna-derived soil organic carbon (SOC) decomposition and oil palm-derived SOC stabilization rates and how they were affected by management practices (mineral fertilization, organic amendments, etc.). Results show that, in opposite to forest conversion, C storage increases when savannas are converted to oil palm plantations. Because soil C storage was very low in natural conditions, SOC changes had little effects on overall C storage. Substitution of savanna-derived SOC by oil palm-derived SOC was very fast in the topsoil and highest under frond pile and weeded circle where C and nutrients inputs are highest. However, stabilization of oil palm-derived SOC compensated loss of savanna-derived SOC rather than increased SOC stocks, indicating high SOC turnover. High turnover are explained by high nutrients inputs and little capacity of Oxisols to physically protect SOC. In conclusion, conversion of savanna to oil palm plantations results in a gain in ecosystem C storage as long as the cultivation lasts. Negative impacts on soil fertility are limited because savanna soils have low initial soil fertility. With more than 7 million ha of well-drained natural savanna grasslands, the Llanos could play a significant role in oil palm development. Nonetheless, a complete assessment of environmental impacts including biodiversity or water consumption is still necessary for the assessment on sustainability of the conversion of savanna to oil palm plantations.
Hanford Waste Physical and Rheological Properties: Data and Gaps
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wells, Beric E.; Kurath, Dean E.; Mahoney, Lenna A.
2011-08-01
The Hanford Site in Washington State manages 177 underground storage tanks containing approximately 250,000 m3 of waste generated during past defense reprocessing and waste management operations. These tanks contain a mixture of sludge, saltcake and supernatant liquids. The insoluble sludge fraction of the waste consists of metal oxides and hydroxides and contains the bulk of many radionuclides such as the transuranic components and 90Sr. The saltcake, generated by extensive evaporation of aqueous solutions, consists primarily of dried sodium salts. The supernates consist of concentrated (5-15 M) aqueous solutions of sodium and potassium salts. The 177 storage tanks include 149 single-shellmore » tanks (SSTs) and 28 double -hell tanks (DSTs). Ultimately the wastes need to be retrieved from the tanks for treatment and disposal. The SSTs contain minimal amounts of liquid wastes, and the Tank Operations Contractor is continuing a program of moving solid wastes from SSTs to interim storage in the DSTs. The Hanford DST system provides the staging location for waste feed delivery to the Department of Energy (DOE) Office of River Protection’s (ORP) Hanford Tank Waste Treatment and Immobilization Plant (WTP). The WTP is being designed and constructed to pretreat and then vitrify a large portion of the wastes in Hanford’s 177 underground waste storage tanks.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-02
... Prospective Purchaser Agreement Related to Gasoline Service Stations' Underground Storage Tanks Currently...) gasoline service stations currently owned or leased by Caribbean Petroleum Corporation (``CPC'') and...
Solar heated office complex--Greenwood, South Carolina
NASA Technical Reports Server (NTRS)
1981-01-01
Report contains thorough docuumentation of project meeting 85 percent of building heat requirements. System uses roof mounted recirculating water solar panels and underground hot water energy storage. Aluminum film reflectors increase total solar flux captured by panels.
Mitigating contaminant transport in utility installation.
DOT National Transportation Integrated Search
2003-01-01
In recent years, the Virginia Department of Transportation (VDOT) has experienced problems with various forms of contamination (primarily from underground storage tanks, USTs) migrating into its right-of-way. In many cases VDOT has had to install cul...
Rajamohan, Sakthivel; Kasimani, Ramesh
2018-04-19
The highly unbalanced nature of bio-oil composition poses a serious threat in terms of storage and utilization of bio-oil as a viable fuel in engines. So it becomes inevitable to study the variations in physicochemical properties of the bio-oil during storage to value its chemical instability, for designing stabilization methodologies. The present study aims to investigate the effects of storage stability of bio-oil extracted from pyrolyzing Calophyllum inophyllum (CI) deoiled seed cake on the engine operating characteristics. The bio-oil is produced in a fixed bed reactor at 500 °C under the constant heating rate of 30 °C/min. All the stability analysis methods involve an accelerated aging procedure based on standards established by ASTM (D5304 and E2009) and European standard (EN 14112). Gas chromatography-mass spectrometry was employed to analytically characterize the unaged and aged bio-oil samples. The results clearly depict that stabilizing Calophyllum inophyllum bio-oil with 10% (w/w) methanol improved its stability than that of the unstabilized sample thereby reducing the aging rate of bio-oil to 0.04 and 0.13 cst/h for thermal and oxidative aging respectively. Engine testing of the bio-oil sample revealed that aged bio-oil samples deteriorated engine performance and increased emission levels at the exhaust. The oxidatively aged sample showed the lowest BTE (24.41%), the highest BSEC (20.14 MJ/kWh), CO (1.51%), HC (132 ppm), NOx (1098 ppm) and smoke opacity (34.8%).
Verma, Ram S; Joshi, Neeta; Padalia, Rajendra C; Singh, Ved R; Goswami, Prakash; Kumar, Ajay; Iqbal, Hina; Verma, Rajesh K; Chanda, Debabrata; Chauhan, Amit; Saikia, Dharmendra
2017-10-01
Fish-mint (Houttuynia cordataThunb.), belonging to family Saururaceae, has long been used as food and traditional herbal medicine. The present study was framed to assess the changes occurring in the essential-oil composition of H. cordata during annual growth and to evaluate allelopathic, antibacterial, antifungal, and antiacetylcholinesterase activities. The essential-oil content ranged from 0.06 - 0.14% and 0.08 - 0.16% in aerial parts and underground stem, respectively. The essential oils were analysed by GC-FID, GC/MS, and NMR ( 1 H and 13 C). Major constituents of aerial-parts oil was 2-undecanone (19.4 - 56.3%), myrcene (2.6 - 44.3%), ethyl decanoate (0.0 - 10.6%), ethyl dodecanoate (1.1 - 8.6%), 2-tridecanone (0.5 - 8.3%), and decanal (1.1 - 6.9%). However, major constituents of underground-stem oil were 2-undecanone (29.5 - 42.3%), myrcene (14.4 - 20.8%), sabinene (6.0 - 11.1%), 2-tridecanone (1.8 - 10.5%), β-pinene (5.3 - 10.0%), and ethyl dodecanoate (0.8 - 7.3%). Cluster analysis revealed that essential-oil composition varied substantially due to the plant parts and season of collection. The oils exhibited significant allelopathic (inhibition: 77.8 - 88.8%; LD 50 : 2.45 - 3.05 μl/plate), antibacterial (MIC: 0.52 - 2.08 μl/ml; MBC: bacteriostatic) and antifungal (MIC: 2.08 - 33.33 μl/ml; MFC: 4.16 - 33.33 μl/ml) activities. The results indicate that the essential oil from H. cordata has a significant potential to allow future exploration and exploitation as a natural antimicrobial and allelopathic agent. © 2017 Wiley-VHCA AG, Zurich, Switzerland.
Aladedunye, Felix; Matthäus, Bertrand
2014-09-15
In the present study, phenolic extracts and fractions from Canadian rowanberry (Sorbus aucuparia) and crabapple (Malus baccata) were screened for antioxidant activity using DPPH radical scavenging activity, and β-carotene bleaching assays. Furthermore, rapeseed oil was supplemented with extracts/fractions and performance was assessed during accelerated storage at 65°C, under Rancimat at 120°C, and during frying at 180°C. A number of phenolic fractions showed significantly higher radical scavenging and antioxidant activity in the oil than the synthetic antioxidant, butylated hydroxytoluene (BHT). At the end of the 7-day storage, the peroxide value was reduced by up to 42% in the presence of extracts. The extent of thermooxidative degradation was significantly lower in oils fortified with the fruit extracts, with fractions from Sorbus species being more effective. Results from the present study suggested that polyphenolic extracts from these fruits can offer effective alternative to synthetic antioxidants during frying and storage of vegetable oils. Copyright © 2014 Elsevier Ltd. All rights reserved.
Quality characteristics of oil extracted from gamma irradiated peanut (Arachis hypogea L.)
NASA Astrophysics Data System (ADS)
Al-Bachir, Mahfouz
2015-01-01
The effect of gamma radiation and storage on the characteristics of oil extracted from peanut seeds has been investigated in this study. Peanut seeds were undergone gamma irradiation process with the doses of 1, 2 and 3 kGy. The changes in chemical and physical attributes were observed immediately after irradiation and after 12 months of storage. The data obtained from the experiments showed that irradiation process had no effect on the chemical and physical qualities such as, fatty acid composition, peroxide value, iodine value specification number, TBA value and color of oil extracted from peanut seeds. On the contrary, the peroxide, acidity and TBA values of the peanut oil were decreased due to storage time.
NASA Astrophysics Data System (ADS)
Jordan, P. D.; Gillespie, J.
2013-12-01
Injection of CO2 during geologic carbon storage pressurizes reservoir fluid, which can cause its migration. Migration of saline water from the reservoir into underground sources of drinking water (USDW) via pathways such as permeable wells and faults is one concern. As of 2010, 2 billion cubic meters (MMMm3) of oil, 10 MMMm3 of water, and 400 MMMm3 of gas had been produced in the southern San Joaquin Valley. A considerable portion of the gas and a majority of the water were injected into production zones for pressure support, water flooding, or as steam for thermal recovery. However a portion of the produced water was disposed of by injection into zones without economic quantities of hydrocarbons, termed saline aquifers in the geologic carbon storage community. These zones often had the shallowest activity in a field, and so had no overlying pressure sink due to production and all oil and gas-related wells in the field encountered or passed through them. The subset of such zones at CO2 storage depths received disposed water volumes equivalent to tens of megatons (MT) of CO2 injected at overpressures of many MPa. For instance a water volume equivalent to over 20 MT of CO2 was injected at a depth of 900 m and an average wellhead pressure of 6 MPa in the Fruitvale oil field, which had almost a thousand wells. Use of USDW for irrigation and consumption is widespread in the area. An increase in total dissolved solids (TDS) in well water is acutely detectable either by taste or effect on crops. Consequently the produced water disposal injection in the southern San Joaquin Valley provides an analog for assessing the occurrence of water leakage impacts due to reservoir pressurization. Almost 230 articles regarding groundwater contamination published from 2000 to 2013 by The Bakersfield Californian, the main newspaper in the area, were assessed. These were written by 71 authors including 38 staff writers, covered 53 different types of facilities or activities that either contaminated groundwater or for which there was such a concern, and discussed 85 different geographic locations. They described groundwater contamination at hundreds of wells during and previous to the publication period. Contamination due to upward leakage caused by produced water disposal injection was not mentioned. Previous research found The Bakersfield Californian covered more well blowouts with the highest public consequence (evacuation) than did reports from the relevant state agency, but had virtually no coverage of the least consequential blow outs. This suggests the lack of reporting of groundwater impacts from leakage due to produced water disposal injection indicates no significant public impact, such as closure of numerous public supply wells, occurred during the article time period or for some years previous. This research continues with analysis of historic groundwater constituent data available from the California State Water Resources Control Board's Geotracker Groundwater Ambient Monitoring & Assessment database. For instance this database contains TDS and other constituent results for 149 wells within or in the immediate vicinity of the Fruitvale oil field.
Flooded Underground Coal Mines: A Significant Source of Inexpensive Geothermal Energy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Watzlaf, G.R.; Ackman, T.E.
2007-04-01
Many mining regions in the United States contain extensive areas of flooded underground mines. The water within these mines represents a significant and widespread opportunity for extracting low-grade, geothermal energy. Based on current energy prices, geothermal heat pump systems using mine water could reduce the annual costs for heating to over 70 percent compared to conventional heating methods (natural gas or heating oil). These same systems could reduce annual cooling costs by up to 50 percent over standard air conditioning in many areas of the country. (Formatted full-text version is released by permission of publisher)
Sharma, Heena; Mendiratta, S K; Agarwal, Ravi Kant; Kumar, Sudheer; Soni, Arvind
2017-02-01
The present study was undertaken to evaluate antimicrobial and antioxidant effect of essential oils on the quality of fresh (raw, ready to cook) chicken sausages. Several preliminary trials were carried out to optimize the level of four essential oils viz., clove oil, holybasil oil, thyme oil and cassia oil and these essential oils were incorporated at 0.25, 0.125, 0.25 and 0.125%, respectively in fresh chicken sausages. Quality evaluation and detailed storage stability studies were carried out for fresh chicken sausages for 20 days at refrigeration temperature (4 ± 1 °C). Refrigerated storage studies revealed that TBARS of control was significantly higher than treatment products whereas, total phenolics and DPPH activity was significantly lower in control. Among treatments, clove oil products had significantly lower TBARS but higher total phenolic content and DPPH activity followed by cassia oil, thyme oil and holybasil oil products. Microbial count of essential oil incorporated products were significantly lower than control and remained well below the permissible limit of fresh meat products (log 10 7 cfu/g). Cassia oil products were observed with better anti-microbial characteristics than clove oil products at 0.25% level of incorporation, whereas, thyme oil products were better than holy basil oil products at 0.125% level. Storage studies revealed that clove oil (0.25%), holy basil oil (0.125%), cassia oil (0.25%) and thyme oil (0.125%) incorporated aerobically packaged and refrigerated fresh chicken sausages had approx. 4-5, 2-3, 5-6 and 2-3 days longer shelf life than control, respectively.
Acoustic Profiling of Bottom Sediments in Large Oil Storage Tanks
NASA Astrophysics Data System (ADS)
Svet, V. D.; Tsysar', S. A.
2018-01-01
Characteristic features of acoustic profiling of bottom sediments in large oil storage tanks are considered. Basic acoustic parameters of crude oil and bottom sediments are presented. It is shown that, because of the presence of both transition layers in crude oil and strong reverberation effects in oil tanks, the volume of bottom sediments that is calculated from an acoustic surface image is generally overestimated. To reduce the error, additional post-processing of acoustic profilometry data is proposed in combination with additional measurements of viscosity and tank density distributions in vertical at several points of the tank.
4. Storage building, outhouse, oil house, keeper's house and light ...
4. Storage building, outhouse, oil house, keeper's house and light tower, view southwest, northeast sides (southeast and northeast sides of keeper's house) - Petit Manan Light Station, 2.5 miles south of Petit Manan Point, Milbridge, Washington County, ME
NASA Astrophysics Data System (ADS)
Kim, K. K.; Hamm, S. Y.; Kim, S. O.; Yun, S. T.
2016-12-01
For confronting global climate change, carbon capture and storage (CCS) is one of several very useful strategies as using capture of greenhouse gases like CO2 spewed from stacks and then isolation of the gases in underground geologic storage. CO2-rich groundwater could be produced by CO2 dissolution into fresh groundwater around a CO2 storage site. As consequence, natural analogue studies related to geologic storage provide insights into future geologic CO2 storage sites as well as can provide crucial information on the safety and security of geologic sequestration, the long-term impact of CO2 storage on the environment, and field operation and monitoring that could be implemented for geologic sequestration. In this study, we developed CO2 leakage monitoring method using probability density function (PDF) by characterizing naturally occurring CO2-rich groundwater. For the study, we used existing data of CO2-rich groundwaters in different geological regions (Gangwondo, Gyeongsangdo, and Choongchungdo provinces) in South Korea. Using PDF method and QI (quantitative index), we executed qualitative and quantitative comparisons among local areas and chemical constituents. Geochemical properties of groundwater with/without CO2 as the PDF forms proved that pH, EC, TDS, HCO3-, Ca2+, Mg2+, and SiO2 were effective monitoring parameters for carbonated groundwater in the case of CO2leakage from an underground storage site. KEY WORDS: CO2-rich groundwater, CO2 storage site, monitoring parameter, natural analogue, probability density function (PDF), QI_quantitative index Acknowledgement This study was supported by the "Basic Science Research Program through the National Research Foundation of Korea (NRF), which is funded by the Ministry of Education (NRF-2013R1A1A2058186)" and the "R&D Project on Environmental Management of Geologic CO2 Storage" from KEITI (Project number: 2014001810003).
Gayoso, Lucía; Poyato, Candelaria; Calvo, María Isabel; Cavero, Rita Yolanda; Ansorena, Diana; Astiasarán, Iciar
2017-08-01
Gelled emulsions with carrageenan are a novel type of emulsion that could be used as a carrier of unsaturated fatty acids in functional foods formulations. Lipid degradation through volatile compounds was studied in gelled emulsions which were high in polyunsaturated oils (sunflower or algae oil) after 49 days of storage. Aqueous Lavandula latifolia extract was tested as a natural antioxidant. Analysis of the complete volatile profile of the samples resulted in a total of 40 compounds, classified in alkanes, alkenes, aldehydes, ketones, acids, alcohols, furans, terpenes and aromatic hydrocarbons. During storage, the formation of the volatile compounds was mostly related to the oxidation of the main fatty acids of the sunflower oil (linolenic acid) and the algae oil (docosahexaenoic acid). Despite the antioxidant capacity shown by the L. latifolia extract, its influence in the oxidative stability in terms of total volatiles was only noticed in sunflower oil gels ( p < 0.05), where a significant decrease in the aldehydes fraction was found.
O' Dwyer, Sandra P; O' Beirne, David; Eidhin, Deirdre Ní; O' Kennedy, Brendan T
2013-06-01
The oxidative stability of various oils (sunflower, camelina and fish) and 20% oil-in-water (O/W) emulsions, were examined. The mean particle size decreased from 1179 to 325 nm as sodium caseinate (emulsifier) concentration was increased from 0.25% to 3% in O/W emulsions (P<0.05). Increasing the microfluidisation pressure from 21 to 138 MPa, resulted in a particle size decrease from 289 to 194 nm (P<0.05). Emulsified oils had lower detectable lipid hydroperoxide and p-Anisidine values than their corresponding bulk oils (P<0.05). The lipid hydroperoxide and p-Anisidine values of emulsions generally decreased as sodium caseinate concentration increased, and similarly decreased as microfluidisation pressure increased (P<0.05). Increasing storage temperature of the emulsions from 5 to 60°C, resulted in lower detectable lipid oxidation products during storage (P<0.05). Copyright © 2012 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1998-06-01
This project constitutes Phase 2 of the Sound Waste Management Plan and created waste oil collection and disposal facilities, bilge water collection and disposal facilities, recycling storage, and household hazardous waste collection and storage, and household hazardous waste collection and storage facilities in Prince William Sound. A wide range of waste streams are generated within communities in the Sound including used oil generated from vehicles and vessels, and hazardous wastes generated by households. This project included the design and construction of Environmental Operations Stations buildings in Valdez, Cordova, Whittier, Chenega Bay and Tatitlek to improve the overall management of oilymore » wastes. They will house new equipment to facilitate oily waste collection, treatment and disposal. This project also included completion of used oil management manuals.« less
Financial Responsibility and Installer Certification - 2005 Energy Policy Act
Grant guidelines to implement the financial responsibility and installer certification provision in Section 9003(i) of the Solid Waste Disposal Act, enacted by the Underground Storage Tank Compliance Act, part of the Energy Policy Act of 2005.
CONTAMINATION OF PUBLIC GROUND WATER SUPPLIES BY SUPERFUND SITES
Multiple sources of contamination can affect ground water supplies, including municipal landfills, industrial operations, leaking underground storage tanks, septic tank systems, and prioritized uncontrolled hazardous waste sites known as “Superfund” sites. A review of Superfund R...
CHEMICALS STORED IN USTS: CHARACTERISTICS AND LEAK DETECTION
The regulations Issued by the U.S. Environmental Protection Agency (EPA) In 1988 require, with several exceptions, that the Integrity of underground storage tank (UST) systems containing petroleum fuels and hazardous chemicals be routinely tested. The regulatory standards for ...
TECHNICAL ASPECTS OF UNDERGROUND STORAGE TANK CLOSURE
The overall objective of the study was to develop a deeper understanding of UST residuals at closure: their quantities, origins, physical/chemical properties, ease of removal by various cleaning methods, and their environmental mobility and persistence. The investigation covered ...
LUST ON-LINE CALCULATOR INTRODUCTION
EPA has developed a suite of on-line calculators to assist in performing site assessment and modeling calculations for leaking underground storage tank sites (http://www.epa.gov/athens/onsite). The calculators are divided into four types: parameter estimation, models, scientific...
Anticipating Environmental Impacts of Future Fuels
Automotive fuels are composed of hundreds of compounds and the formulations aren’t uniform; they vary geographically and seasonally and sometimes specifically in response to regulatory requirements. As a result, very few state underground storage tank (UST) regulators know what i...
24 CFR 581.6 - Suitability criteria.
Code of Federal Regulations, 2010 CFR
2010-04-01
..., the property will not be determined unsuitable on this basis. (2) Property containing flammable or... handling flammable or explosive material (excluding underground storage) will be determined unsuitable..., friable asbestos, PCB's, or natural hazardous substances such as radon, periodic flooding, sinkholes or...
Method for storing nuclear fuel in respositories
Schweitzer, D.G.; Sastre, C.
A method for storing radioactive spent fuel in repositories containing polyphenyl or silicon oil as the storage medium is disclosed. Polyphenyls and silicon oils are non-corrosive and are not subject to radiation damage. Thus, storage periods of up to 100 years are possible.
Ling, Stella Sye Chee; Chang, Sui Kiat; Sia, Winne Chiaw Mei; Yim, Hip Seng
2015-01-01
Sunflower oil is prone to oxidation during storage time, leading to production of toxic compounds that might affect human health. Synthetic antioxidants are used to prevent lipid oxidation. Spreading interest in the replacement of synthetic food antioxidants by natural ones has fostered research on fruit and vegetables for new antioxidants. In this study, the efficacy of unripe banana peel extracts (100, 200 and 300 ppm) in stabilizing sunflower oil was tested under accelerated storage (65°C) for a period of 24 days. BHA and α-tocopherol served as comparative standards besides the control. Established parameters such as peroxide value (PV), iodine value (IV), p-anisidine value (p-AnV), total oxidation value (TOTOX), thiobarbituric acid reactive substances (TBARS) and free fatty acid (FFA) content were used to assess the extent of oil deterioration. After 24 days storage at 65°C, sunflower oil containing 200 and 300 ppm extract of unripe banana peel showed significantly lower PV and TOTOX compared to BHA and α-tocopherol. TBARS, p-AnV and FFA values of sunflower oil containing 200 and 300 ppm of unripe banana peel extract exhibited comparable inhibitory effects with BHA. Unripe banana peel extract at 200 and 300 ppm demonstrated inhibitory effect against both primary and secondary oxidation up to 24 days under accelerated storage conditions. Unripe banana peel extract may be used as a potential source of natural antioxidants in the application of food industry to suppress lipid oxidation.
Yang, Feifei; Hingerl, Ferdinand F.; Xiao, Xianghui; ...
2015-06-03
The elevated level of atmospheric carbon dioxide (CO 2) has caused serious concern of the progression of global warming. Geological sequestration is considered as one of the most promising techniques for mitigating the damaging effect of global climate change. Investigations over wide range of length-scales are important for systematic evaluation of the underground formations from prospective CO 2 reservoir. Understanding the relationship between the micro morphology and the observed macro phenomena is even more crucial. Here we show Synchrotron based X-ray micro tomographic study of the morphological buildup of Sandstones. We present a numerical method to extract the pore sizesmore » distribution of the porous structure directly, without approximation or complex calculation. We have also demonstrated its capability in predicting the capillary pressure curve in a mercury intrusion porosimetry (MIP) measurement. The method presented in this work can be directly applied to the morphological studies of heterogeneous systems in various research fields, ranging from Carbon Capture and Storage, and Enhanced Oil Recovery to environmental remediation in the vadose zone.« less
Major sources of benzene exposure.
Wallace, L A
1989-01-01
Data from EPA's TEAM Study allow us to identify the major sources of exposure to benzene for much of the U.S. population. These sources turn out to be quite different from what had previously been considered the important sources. The most important source of exposure for 50 million smokers is the mainstream smoke from their cigarettes, which accounts for about half of the total population burden of exposure to benzene. Another 20% of nationwide exposure is contributed by various personal activities, such as driving and using attached garages. (Emissions from consumer products, building materials, paints, and adhesives may also be important, although data are largely lacking.) The traditional sources of atmospheric emissions (auto exhaust and industrial emissions) account for only about 20% of total exposure. Environmental tobacco smoke is an important source, accounting for about 5% of total nationwide exposure. A number of sources sometimes considered important, such as petroleum refining operations, petrochemical manufacturing, oil storage tanks, urban-industrial areas, service stations, certain foods, groundwater contamination, and underground gasoline leaks, appear to be unimportant on a nationwide basis. PMID:2477239
NASA Astrophysics Data System (ADS)
Gibson, Hazel; Stewart, Iain; Anderson, Mark; Pahl, Sabine; Stokes, Alison
2014-05-01
Geological issues are increasingly intruding on the everyday lives of ordinary people. Whether it be onshore exploration and extraction of oil and gas, deep injection of water for geothermal power or underground storage of carbon dioxide and radioactive waste, many communities across Europe are being faced with potentially contested geological activity under their backyard. As well as being able to communicate the technical aspects of such work, geoscience professionals also need to appreciate that for most people the subsurface is an unfamiliar realm. In order to engage communities and individuals in effective dialogue about geological activities, an appreciation of what 'the public' already know and what they want to know is needed, but this is a subject that is in its infancy. In an attempt to provide insight into these key issues, this study examines the concerns the public have, relating to geology, by constructing 'Mental Models' of people's perceptions of the subsurface. General recommendations for public engagement strategies will be presented based on the results of selected case studies; specifically expert and non-expert mental models for communities in the south-west of England.
Oil reserve: status of Strategic Petroleum Reserve activities as of December 31, 1985
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
This report discusses events and activities related to the administration's progress in filling, developing, and operating the Strategic Petroleum Reserve (SPR) during the first quarter of fiscal year 1986. Specifically, it notes that: DOE added 4.5 million barrels of oil to the SPR, bringing the total to 493.3 million barrels. The oil fill rate averaged about 49,000 barrels per day during the quarter. DOE made payments of $178 million for oil acquisition and transportation, had unpaid obligations of about $140 million, and had about $668 million in unobligated funds. The storage capacity development program proceeded during the quarter; however, themore » West Hackberry, Louisiana site's leaching program was stopped in December due to a leak in the brine disposal line. DOE held an SPR drawdown test sale and distribution exercise. Approximately 1 million barrels of oil were competitively sold to oil company bidders and subsequently withdrawn from DOE storage sites for delivery. The Congress passed a continuing resolution for fiscal year 1986 providing about $113 million for continued construction of storage capacity as directed by the fiscal year 1985 Supplemental Appropriations Act. On December 27, 1985, DOE formally notified cognizant congressional committees that it was planning to submit a deferral of funds for SPR storage facilities development. This report also presents information on (1) the implementation of recommendations made in the DOE Oak Ridge Operations Office's reports on its baseline assessment of the SPR Project Office and its review of allegations about mismanagement or misconduct within the SPR program, (2) DOE's compliance with the Cargo Preference Act of 1954 during the 1985 crude oil procurement program, (3) DOE's program to analyze the quality of oil in filled storage caverns, and (4) DOE's pipeline construction and marine terminal enhancements to improve the SPR oil distribution system.« less
A Guidance Document for Kentucky's Oil and Gas Operators
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bender, Rick
The accompanying report, manual and assimilated data represent the initial preparation for submission of an Application for Primacy under the Class II Underground Injection Control (UIC) program on behalf of the Commonwealth of Kentucky. The purpose of this study was to identify deficiencies in Kentucky law and regulation that would prevent the Kentucky Division of Oil and Gas from receiving approval of primacy of the UIC program, currently under control of the United States Environmental Protection Agency (EPA) in Atlanta, Georgia.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Frame, E.A.
The objectives of this project were: (1) to determine the feasibility of adding a vapor-phase corrosion inhibitor (VCI) component to improve the preservation performance of MIL-L-21260 and (2) to evaluate a less complicated engine preservation procedure. A simultaneous two-phase approach was conducted. Phase 1 involved the formulation and evaluation of experimental VCI oils, while Phase 2 was the evaluation of a simplified engine preservation procedure. VCI oil formulation was conducted by Ronco Laboratory under subcontract. Compatibility of the experimental VCI oils with metal coupons, elastomers, and fuel filters was determined. Effectiveness of the experimental VCI oil was evaluated in amore » 3-year outdoor engine storage test. The engines were preserved using an experimental, simplified preservation procedure. The simplified engine preservation procedure proved to be acceptable as engines stored for 3 years in a very severe environment were judged to have been adequately preserved. Engine oil meeting specification MIL-L-21260 provided satisfactory protection during the 3-year storage test. The experimental VCI oil also provided satisfactory storage protection during this test; however, there was no observable advantage for the VCI oil. The VCI oil had acceptable compatibility with an elastomeric flex ring, metal coupons (except lead), and fuel filters.« less
Pipeline safety : the office of pipeline safety is changing how it oversees the pipeline industry
DOT National Transportation Integrated Search
2000-05-01
Pipelines are inherently safer to the public than other modes of freight transportation for natural gas and hazardous liquids (such as oil products) because they are, for the most part, located underground. Nevertheless, the volatile nature of these ...
Pipeline Safety: The Office of Pipeline Safety Is Changing How It Oversees the Pipeline Industry
DOT National Transportation Integrated Search
2000-05-01
Pipelines are inherently safer to the public than other modes of freight transportation for natural gas and hazardous liquids (such as oil products) because they are, for the most part, located underground. Nevertheless, the volatile nature of these ...
NASA Astrophysics Data System (ADS)
Mishra, Rahul Kumar; soota, Tarun, Dr.; singh, Ranjeet
2017-08-01
Rapid exploration and lavish consumption of underground petroleum resources have led to the scarcity of underground fossil fuels moreover the toxic emissions from such fuels are pernicious which have increased the health hazards around the world. So the aim was to find an alternative fuel which would meet the requirements of petroleum or fossil fuels. Biodiesel is a clean, renewable and bio-degradable fuel having several advantages, one of the most important of which is being its eco-friendly and better knocking characteristics than diesel fuel. In this work the performance of Karanja oil was analyzed on a four stroke, single cylinder, water cooled, variable compression ratio diesel engine. The fuel used was 5% - 25% karanja oil methyl ester by volume in diesel. The results such obtained are compared with standard diesel fuel. Several properties i.e. Brake Thermal Efficiency, Brake Specific Fuel Consumptions, Exhaust Gas Temperature are determined at all operating conditions & at variable compression ratio 17 and 17.5.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Graf, D.C.; Warpinski, N.R.
Laboratory measurements of single-phase, steady-state permeability of porous rock are important for a number of different applications. The oil and gas industry uses permeability data as a key indicator of the producability of a hydrocarbon reservoir; effective containment of large volumes of oil in underground salt caverns is directly dependent upon the permeability of the adjacent cavern walls; and safe, long term underground isolation of radioactive and hazardous waste is contingent upon the flow and transport characteristics of the surrounding geologic formations. An alternative method for measuring single-phase, steady-state permeability of porous rock is presented. The use of troublesome andmore » expensive mass flow meters is eliminated and replaced with a bridge configuration of flow resistors. Permeability values can be determined directly from differential pressures across the bridge network, resulting in potentially significant cost savings and simplification for conducting these types of measurements. Results from the bridge permeameter are compared with results obtained using conventional methods.« less
Analysis and assessment of STES technologies
NASA Astrophysics Data System (ADS)
Brown, D. R.; Blahnik, D. E.; Huber, H. D.
1982-12-01
Technical and economic assessments completed in FY 1982 in support of the Seasonal Thermal Energy Storage (STES) segment of the Underground Energy Storage Program included: (1) a detailed economic investigation of the cost of heat storage in aquifers, (2) documentation for AQUASTOR, a computer model for analyzing aquifer thermal energy storage (ATES) coupled with district heating or cooling, and (3) a technical and economic evaluation of several ice storage concepts. This paper summarizes the research efforts and main results of each of these three activities. In addition, a detailed economic investigation of the cost of chill storage in aquifers is currently in progress. The work parallels that done for ATES heat storage with technical and economic assumptions being varied in a parametric analysis of the cost of ATES delivered chill. The computer model AQUASTOR is the principal analytical tool being employed.
Gis-Based Site Selection for Underground Natural Resources Using Fuzzy Ahp-Owa
NASA Astrophysics Data System (ADS)
Sabzevari, A. R.; Delavar, M. R.
2017-09-01
Fuel consumption has significantly increased due to the growth of the population. A solution to address this problem is the underground storage of natural gas. The first step to reach this goal is to select suitable places for the storage. In this study, site selection for the underground natural gas reservoirs has been performed using a multi-criteria decision-making in a GIS environment. The "Ordered Weighted Average" (OWA) operator is one of the multi-criteria decision-making methods for ranking the criteria and consideration of uncertainty in the interaction among the criteria. In this paper, Fuzzy AHP_OWA (FAHP_OWA) is used to determine optimal sites for the underground natural gas reservoirs. Fuzzy AHP_OWA considers the decision maker's risk taking and risk aversion during the decision-making process. Gas consumption rate, temperature, distance from main transportation network, distance from gas production centers, population density and distance from gas distribution networks are the criteria used in this research. Results show that the northeast and west of Iran and the areas around Tehran (Tehran and Alborz Provinces) have a higher attraction for constructing a natural gas reservoir. The performance of the used method was also evaluated. This evaluation was performed using the location of the existing natural gas reservoirs in the country and the site selection maps for each of the quantifiers. It is verified that the method used in this study is capable of modeling different decision-making strategies used by the decision maker with about 88 percent of agreement between the modeling and test data.
Development of the updated system of city underground pipelines based on Visual Studio
NASA Astrophysics Data System (ADS)
Zhang, Jianxiong; Zhu, Yun; Li, Xiangdong
2009-10-01
Our city has owned the integrated pipeline network management system with ArcGIS Engine 9.1 as the bottom development platform and with Oracle9i as basic database for storaging data. In this system, ArcGIS SDE9.1 is applied as the spatial data engine, and the system was a synthetic management software developed with Visual Studio visualization procedures development tools. As the pipeline update function of the system has the phenomenon of slower update and even sometimes the data lost, to ensure the underground pipeline data can real-time be updated conveniently and frequently, and the actuality and integrity of the underground pipeline data, we have increased a new update module in the system developed and researched by ourselves. The module has the powerful data update function, and can realize the function of inputting and outputting and rapid update volume of data. The new developed module adopts Visual Studio visualization procedures development tools, and uses access as the basic database to storage data. We can edit the graphics in AutoCAD software, and realize the database update using link between the graphics and the system. Practice shows that the update module has good compatibility with the original system, reliable and high update efficient of the database.
Environmental analysis Waste Isolation Pilot Plant (WIPP) cost reduction proposals
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
The Waste Isolation Pilot Plant (WIPP) is a research and development facility to demonstrate the safe disposal of radioactive wastes resulting from the defense activities and programs of the United States government. The facility is planned to be developed in bedded salt at the Los Medanos site in southeastern New Mexico. The environmental consequences of contruction and operation of the WIPP facility are documented in ''Final Environmental Impact Statement, Waste Isolation Pilot Plant''. The proposed action addressed by this environmental analysis is to simplify and reduce the scope of the WIPP facility as it is currently designed. The proposed changesmore » to the existing WIPP design are: limit the waste storage rate to 500,000 cubic feet per year; eliminate one shaft and revise the underground ventilation system; eliminate the underground conveyor system; combine the Administration Building, the Underground Personnel Building and the Waste Handling Building office area; simplify the central monitoring system; simplify the security control systems; modify the Waste Handling Building; simplify the storage exhaust system; modify the above ground salt handling logistics; simplify the power system; reduce overall site features; simplify the Warehouse/Shops Building and eliminate the Vehicle Maintenance Building; and allow resource recovery in Control Zone IV.« less
Storage, transmission and distribution of hydrogen
NASA Technical Reports Server (NTRS)
Kelley, J. H.; Hagler, R., Jr.
1979-01-01
Current practices and future requirements for the storage, transmission and distribution of hydrogen are reviewed in order to identify inadequacies to be corrected before hydrogen can achieve its full potential as a substitute for fossil fuels. Consideration is given to the storage of hydrogen in underground solution-mined salt caverns, portable high-pressure containers and dewars, pressure vessels and aquifers and as metal hydrides, hydrogen transmission in evacuated double-walled insulated containers and by pipeline, and distribution by truck and internal distribution networks. Areas for the improvement of these techniques are indicated, and these technological deficiencies, including materials development, low-cost storage and transmission methods, low-cost, long-life metal hydrides and novel methods for hydrogen storage, are presented as challenges for research and development.
Status of Geological Storage of CO2 as Part of Negative Emissions Strategy
NASA Astrophysics Data System (ADS)
Benson, S. M.
2014-12-01
Recent analyses show that many GHG stabilization scenarios require technologies that permanently extract CO2 from the atmosphere -so-called "net negative emissions." Among the most promising negative emissions approaches is bioenergy with carbon capture and storage (BECCS). The most mature options for CO2 storage are in sedimentary rocks located in thick sedimentary basins. Within those basins, CO2 can be stored either in depleted or depleting hydrocarbon formations or in so-called saline aquifers. In addition to the economic costs of bioenergy with CO2 capture, key to the success of and scale at which BECCS can contribute to negative emissions is the ability to store quantities on the order of 1 Gt per year of CO2. Today, about 65 Mt of CO2 per year are injected underground for the purposes of enhancing oil recovery (CO2-EOR) or for CO2 storage, the vast majority being for CO2-EOR. Achieving 1 Gt per year of negative emissions will require a 15-fold scale up of the current injection operations. This paper will review the conditions necessary for storage at this scale, identify what has been learned from nearly 2 decades of experience with CO2 storage that provides insight into the feasibility of CO2 storage on this scale, and identify critical issues that remain to be resolved to meet these ambitious negative emissions targets. Critical technological issues include but are not limited to: the amount of CO2 storage capacity that is available and where it is located in relation to biomass energy resources; identification of sustainable injection rates and how this depends on the properties of the geological formation; the extent to which water extraction will be required to manage the magnitude of pressure buildup; identification of regions at high risk for induced seismicity that could damage structures and infrastructure; and selection of sites with a adequate seals to permanently contain CO2. Social, economic and political issues are also important: including the support for and confidence in the projects by the local population; scale at which these projects are financially feasible; resolution of issues such as who pays and who benefits from these projects; and development of regulatory frameworks that are at the same time, environmentally protective and not overly burdensome.
Tank atmosphere perturbation: a procedure for assessing flashing losses from oil storage tanks.
Littlejohn, David; Lucas, Donald
2003-03-01
A new procedure to measure the total volume of emissions from heavy crude oil storage tanks is described. Tank flashing losses, which are difficult to measure, can be determined by correcting this value for working and breathing losses. The procedure uses a fan or blower to vent the headspace of the storage tank, with subsequent monitoring of the change in concentrations of oxygen or other gases. Combined with a separate determination of the reactive organic carbon (ROC) fraction in the gas, this method allows the evaluation of the total amount of ROC emitted. The operation of the system is described, and results from measurement of several storage tanks in California oil fields are presented. Our measurements are compared with those obtained using the California Air Resources Board (CARB) 150 method.
Santos, Vanessa S; Souza, Vinicius P; Vilhalva, Divina A A; Ferreira, Fernanda P S; Paula, José R; Rezende, Maria Helena
2016-03-01
The occurrence of thickened underground systems in Asteraceae is widely reported in the literature. Given the great complexity of underground systems, which may originate from roots, stems, or both, morpho-anatomical analyses are essential to ensure the use of correct terminology. The goals of this study were to describe the morpho-anatomy and ontogeny, investigate the occurrence of secondary metabolites and evaluate the effects of seasonality on the underground system of Chrysolaena simplex (Less.) Dematt. Samples were studied using standard protocols of plant anatomy, scanning electron microscopy, histochemical and phytochemical. The underground system of C. simplex was categorised as a rhizophore which started from cotyledonary node. In adult individuals, with rhizophores completely developed, the primary roots degenerated and adventitious radicular systems are formed. The buds in the subterranean portions promote the rhizophore growing, and form aerial stems when exposed to light. Lipophilic droplets were evident in the parenchymatous cells of the cortex and pith, endodermis and buds. Inulin-type fructans were observed in the stem axis and buds of the rhizophore. The presence of buds, secondary metabolites and the storage of fructans and lipids in the rhizophore can be seen as adaptive traits.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gutierrez, Marte
Colorado School of Mines conducted research and training in the development and validation of an advanced CO{sub 2} GS (Geological Sequestration) probabilistic simulation and risk assessment model. CO{sub 2} GS simulation and risk assessment is used to develop advanced numerical simulation models of the subsurface to forecast CO2 behavior and transport; optimize site operational practices; ensure site safety; and refine site monitoring, verification, and accounting efforts. As simulation models are refined with new data, the uncertainty surrounding the identified risks decrease, thereby providing more accurate risk assessment. The models considered the full coupling of multiple physical processes (geomechanical and fluidmore » flow) and describe the effects of stochastic hydro-mechanical (H-M) parameters on the modeling of CO{sub 2} flow and transport in fractured porous rocks. Graduate students were involved in the development and validation of the model that can be used to predict the fate, movement, and storage of CO{sub 2} in subsurface formations, and to evaluate the risk of potential leakage to the atmosphere and underground aquifers. The main major contributions from the project include the development of: 1) an improved procedure to rigorously couple the simulations of hydro-thermomechanical (H-M) processes involved in CO{sub 2} GS; 2) models for the hydro-mechanical behavior of fractured porous rocks with random fracture patterns; and 3) probabilistic methods to account for the effects of stochastic fluid flow and geomechanical properties on flow, transport, storage and leakage associated with CO{sub 2} GS. The research project provided the means to educate and train graduate students in the science and technology of CO{sub 2} GS, with a focus on geologic storage. Specifically, the training included the investigation of an advanced CO{sub 2} GS simulation and risk assessment model that can be used to predict the fate, movement, and storage of CO{sub 2} in underground formations, and the evaluation of the risk of potential CO{sub 2} leakage to the atmosphere and underground aquifers.« less
USING SUBSURFACE TRANSPORT RESEARCH TO ACHIEVE AGENCY OUTCOMES
Gasoline leaks from underground storage tanks can cause ground water contamination because there are a number of organic chemicals in gasoline. These chemicals have varying properties that influence how far contamination extends from the release. Research on transport of these ...
FATE AND TRANSPORT OF PETROLEUM RELEASED FROM UNDERGROUND STORAGE TANKS in Areas of Karst Topography
The study determines the transport and ultimate fate of petroleum products within a region of karst geomorphology. The paper entails a complete literature review, including references that pertain to contaminant transport within karst aquifers
Code of Federal Regulations, 2010 CFR
2010-07-01
... Amendments and Reauthorization Act of 1986. Septic tank is a water-tight covered receptacle designed to... premises where stored; (c) Septic tank; (d) Pipeline facility (including gathering lines) regulated under... STANDARDS AND CORRECTIVE ACTION REQUIREMENTS FOR OWNERS AND OPERATORS OF UNDERGROUND STORAGE TANKS (UST...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-29
... underground storage tank (UST) facilities; failure to perform annual tests of automatic line leak detectors... detectors for piping on the UST systems. CHEVRON also agrees under the Consent Decree to install dispenser...
VOLUMETRIC TANK TESTING: AN OVERVIEW
This report summarizes the technical findings of an EPA study on volumetric tank testing. The results of this study, which evaluated the viability of volumetric tank tests as a means of detecting leaks in underground storage tanks, are described. Also, the accuracy requirements s...
ERIC Educational Resources Information Center
Governick, Heather; Wellington, Thom
1998-01-01
Examines the options for upgrading, replacing, and removal or closure of underground storage tanks (UST). Reveals the diverse regulatory control involving USTs, the Environmental Protection Agency's interest in pursuing violators, and stresses the need for administrators to be knowledgeable about state and local agency definitions of regulated…
High temperature thermal energy storage, including a discussion of TES integrated into power plants
NASA Technical Reports Server (NTRS)
Turner, R. H.
1978-01-01
Storage temperatures of 260 C and above are considered. Basic considerations concerning energy thermal storage are discussed, taking into account general aspects of thermal energy storage, thermal energy storage integrated into power plants, thermal storage techniques and technical considerations, and economic considerations. A description of system concepts is provided, giving attention to a survey of proposed concepts, storage in unpressurized fluids, water storage in pressurized containers, the use of an underground lined cavern for water storage, a submerged thin insulated steel shell under the ocean containing pressurized water, gas passage through solid blocks, a rock bed with liquid heat transport fluid, hollow steel ingots, heat storage in concrete or sand, sand in a fluidized bed, sand poured over pipes, a thermal energy storage heat exchanger, pipes or spheres filled with phase change materials (PCM), macroencapsulated PCM with heat pipe concept for transport fluid, solid PCM removed from heat transfer pipes by moving scrapers, and the direct contact between PCM and transport fluid.
Gamma radiation combined with cinnamon oil to maintain fish quality
NASA Astrophysics Data System (ADS)
Lyu, Fei; Zhang, Jing; Wei, Qianqian; Gao, Fei; Ding, Yuting; Liu, Shulai
2017-12-01
Effects of gamma radiation combined with cinnamon oil on quality of Northern Snakehead fish fillets were observed during storage at 4 °C. Fish fillets were treated with 1-5 kGy gamma radiation, 0.05-0.5% cinnamon oil or the combination of radiation and cinnamon oil. The antimicrobial activity increased with radiation dose and cinnamon oil concentration. During storage, the combination of 1 kGy radiation and 0.5% cinnamon oil displayed better inhibiting activities on aerobic plate counts, total volatile basic nitrogen, thiobarbituric acid reaction substances than 1 kGy radiation or 0.5% cinnamon oil used alone. Moreover, the combination could arrive at the similar inhibiting activities of cinnamon oil with higher concentration of 0.5% or radiation with higher dose of 5 kGy. Thus, the combination could decrease the radiation dose and cinnamon oil concentration without decreasing the effect of them on maintaining fish quality.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Myers, C.W.; Giraud, K.M.
Newcomer countries expected to develop new nuclear power programs by 2030 are being encouraged by the International Atomic Energy Agency to explore the use of shared facilities for spent fuel storage and geologic disposal. Multinational underground nuclear parks (M-UNPs) are an option for sharing such facilities. Newcomer countries with suitable bedrock conditions could volunteer to host M-UNPs. M-UNPs would include back-end fuel cycle facilities, in open or closed fuel cycle configurations, with sufficient capacity to enable M-UNP host countries to provide for-fee waste management services to partner countries, and to manage waste from the M-UNP power reactors. M-UNP potential advantagesmore » include: the option for decades of spent fuel storage; fuel-cycle policy flexibility; increased proliferation resistance; high margin of physical security against attack; and high margin of containment capability in the event of beyond-design-basis accidents, thereby reducing the risk of Fukushima-like radiological contamination of surface lands. A hypothetical M-UNP in crystalline rock with facilities for small modular reactors, spent fuel storage, reprocessing, and geologic disposal is described using a room-and-pillar reference-design cavern. Underground construction cost is judged tractable through use of modern excavation technology and careful site selection. (authors)« less
Yield Determination of Underground and Near Surface Explosions
NASA Astrophysics Data System (ADS)
Pasyanos, M.
2015-12-01
As seismic coverage of the earth's surface continues to improve, we are faced with signals from a wide variety of explosions from various sources ranging from oil train and ordnance explosions to military and terrorist attacks, as well as underground nuclear tests. We present on a method for determining the yield of underground and near surface explosions, which should be applicable for many of these. We first review the regional envelope method that was developed for underground explosions (Pasyanos et al., 2012) and more recently modified for near surface explosions (Pasyanos and Ford, 2015). The technique models the waveform envelope templates as a product of source, propagation (geometrical spreading and attenuation), and site terms, while near surface explosions include an additional surface effect. Yields and depths are determined by comparing the observed envelopes to the templates and minimizing the misfit. We then apply the method to nuclear and chemical explosions for a range of yields, depths, and distances. We will review some results from previous work, and show new examples from ordnance explosions in Scandinavia, nuclear explosions in Eurasia, and chemical explosions in Nevada associated with the Source Physics Experiments (SPE).
Xing, Yage; Lin, Hongbin; Cao, Dong; Xu, Qinglian; Han, Wenfeng; Wang, Ranran; Che, Zhenming; Li, Xihong
2015-01-01
Effects of chitosan coating with cinnamon oil on the physiological attributes and preservation quality of China jujube fruits during storage at 4°C for 60 days were investigated. Results indicated that weight loss and decay of jujube fruits were significantly reduced by chitosan-oil coating during the period of 60-day storage, which also exhibited a quite beneficial effect on maintaining the sensory quality for jujube fruits. Meanwhile, the contents of vitamin C and titratable acid decreased to 3.08 mg·g−1 and 0.342% for the fruits treated by chitosan-oil coating (1.0% + 0.10%), respectively. Polyphenol oxidase, superoxide dismutase, and peroxidase activities were 13.40 U·g−1, 14.53 U·g−1, and 63.6 U·g−1 at the end of storage, respectively. The contents of total soluble phenolics and MDA were 34.51 mg·g−1 and 19.43 μmol·g−1 for the combined coating treated samples and control fruits, respectively. These results suggested that the chitosan-oil coating might be recognized as one efficiency technology on the preservation quality of jujube fruits during the storage time. PMID:26495315
Huang, Zhan; Liu, Xiaochang; Jia, Shiliang; Zhang, Longteng; Luo, Yongkang
2018-02-02
Antimicrobial and antioxidant effects of essential oils (oregano, thyme, and star anise) on microbial composition and quality of grass carp fillets were investigated. Essential oils treatment was found to be effective in inhibiting microbial growth, delaying lipid oxidation, and retarding the increase of TVB-N, putrescine, hypoxanthine, and K-value. Based on sensory analysis, shelf-life of grass carp fillets was 6days for control and 8days for treatment groups. Among the essential oils, oregano essential oil exhibited the highest antimicrobial and antioxidant activities. GC-MS analysis of essential oils components revealed that carvacrol (88.64%) was the major component of oregano essential oil. According to the results of high-throughput sequencing, Aeromonas, Glutamicibacter, and Aequorivita were the predominant microbiota in fresh control samples. However, oregano essential oil decreased the relative abundance of Aeromonas, while thyme and star anise essential oils decreased the relative abundance of Glutamicibacter and Aequorivita in fresh treated samples. The microbial composition of both control and treatment groups became less diverse as storage time increased. Aeromonas and Pseudomonas were dominant in spoiled samples and contributed to fish spoilage. Compared to the control, essential oils effectively inhibited the growth of Aeromonas and Shewanella in grass carp fillets during chilled storage. Copyright © 2017 Elsevier B.V. All rights reserved.
Rigorous Screening Technology for Identifying Suitable CO2 Storage Sites II
DOE Office of Scientific and Technical Information (OSTI.GOV)
George J. Koperna Jr.; Vello A. Kuuskraa; David E. Riestenberg
2009-06-01
This report serves as the final technical report and users manual for the 'Rigorous Screening Technology for Identifying Suitable CO2 Storage Sites II SBIR project. Advanced Resources International has developed a screening tool by which users can technically screen, assess the storage capacity and quantify the costs of CO2 storage in four types of CO2 storage reservoirs. These include CO2-enhanced oil recovery reservoirs, depleted oil and gas fields (non-enhanced oil recovery candidates), deep coal seems that are amenable to CO2-enhanced methane recovery, and saline reservoirs. The screening function assessed whether the reservoir could likely serve as a safe, long-term CO2more » storage reservoir. The storage capacity assessment uses rigorous reservoir simulation models to determine the timing, ultimate storage capacity, and potential for enhanced hydrocarbon recovery. Finally, the economic assessment function determines both the field-level and pipeline (transportation) costs for CO2 sequestration in a given reservoir. The screening tool has been peer reviewed at an Electrical Power Research Institute (EPRI) technical meeting in March 2009. A number of useful observations and recommendations emerged from the Workshop on the costs of CO2 transport and storage that could be readily incorporated into a commercial version of the Screening Tool in a Phase III SBIR.« less
Alarcón-Moyano, Jessica K; Bustos, Rubén O; Herrera, María Lidia; Matiacevich, Silvia B
2017-08-01
Active edible films have been proposed as an alternative to extend shelf life of fresh foods. Most essential oils have antimicrobial properties; however, storage conditions could reduce their activity. To avoid this effect the essential oil (EO) can be microencapsulated prior to film casting. The aim of this study was to determine the effects of the type of encapsulating agent (EA), type of EO and storage time on physical properties and antimicrobial activity of alginate-based films against Escherichia coli ATCC 25922. Trehalose (TH), Capsul ® (CAP) and Tween 20 (Tw20) were used as EA. Lemongrass essential oil (LMO) and citral were used as active agents. The results showed that the type of EA affected the stability of the film forming-emulsions as well as the changes in opacity and colour of the films during storage but not the antimicrobial activity of them. Both microencapsulated EOs showed a prolonged release from the alginate films during the 28 days of storage. Trehalose was selected to encapsulate both active compounds because the films made with this microencapsulated EA showed the greatest physical stability and the lowest color variation among all the films studied.
NASA Astrophysics Data System (ADS)
Zogala, B.; Dubiel, R.; Zuberek, W. M.; Rusin-Zogala, M.; Steininger, M.
2009-07-01
The survey has been carried out in the area of 0.23 km2 of the former military underground fuel base. The oil derivative products were observed in excavations and the laboratory tests confirmed the occurrence of hydrocarbons (>C12) in soils. The purpose of the survey was to determine the spatial extent of the contamination. The studied area is covered by postglacial sediments: sands, gravels and till. The first water table was observed at a depth of 10-12 m. The detailed electromagnetic measurements with Geonics EM31-MK2 conductivity meter were performed in the whole area of the former fuel base. Obtained results were elaborated statistically and the map of apparent electrical conductivity to a depth of 6 m was created. Many local low conductivity anomalies were observed. The measurements with Geonics EM34-3XL were performed along one A-A' profile and 1D electromagnetic modelling along with this profile was calculated to obtain the electrical conductivity cross-section to a depth of 30 m. Two-dimensional electrical resistivity imaging measurements were carried out along the same profile and the resistivity cross-section to a depth of 20 m was performed. Both conducivity and resistivity cross-sections show anomalous zones. The zones correlate with oil contaminated zones very well.
Minutes of the 23rd Eplosives Safety Seminar, volume 2
NASA Astrophysics Data System (ADS)
1988-08-01
Some areas of discussion at this seminar were: Hazards and risks of the disposal of chemical munitions using a cryogenic process; Special equipment for demilitarization of lethal chemical agent filled munitions; explosive containment room (ECR) repair Johnston Atoll chemical agent disposal system; Sympathetic detonation testing; Blast loads, external and internal; Structural reponse testing of walls, doors, and valves; Underground explosion effects, external airblast; Explosives shipping, transportation safety and port licensing; Explosive safety management; Underground explosion effects, model test and soil rock effects; Chemical risk and protection of workers; and Full scale explosives storage test.
WATER PUMP HOUSE, TRA619, AND TWO WATER STORAGE RESERVOIRS. INDUSTRIAL ...
WATER PUMP HOUSE, TRA-619, AND TWO WATER STORAGE RESERVOIRS. INDUSTRIAL WINDOWS AND COPING STRIPS AT TOP OF WALLS AND ENTRY VESTIBULE. BOLLARDS PROTECT UNDERGROUND FACILITIES. SWITCHYARD AT RIGHT EDGE OF VIEW. CARD IN LOWER RIGHT WAS INSERTED BY INL PHOTOGRAPHER TO COVER AN OBSOLETE SECURITY RESTRICTION PRINTED ON ORIGINAL NEGATIVE. INL NEGATIVE NO. 3816. Unknown Photographer, 11/28/1951 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Yang, Ping-Heng; Yuan, Dao-Xian; Ren, You-Rong; Xie, Shi-You; He, Qiu-Fang; Hu, Xiao-Feng
2012-09-01
In order to investigate the nitrate storage and transport in the karst aquifer system, the hydrochemical dynamics of Qingmuguan underground river system was monitored online by achieving high-resolution data during storm events and monthly data in normal weather. The principal component analysis was employed to analyze the karst water geochemistry. Results showed that nitrate in Jiangjia spring did not share the same source with soluble iron, manganese and aluminum, and exhibited different geochemical behaviors. Nitrate was derived from land surface and infiltrated together with soil water, which was mainly stored in fissure, pore and solution crack of karst unsaturated zone, whereas soluble iron, manganese and aluminum were derived from soil erosion and directly recharged the underground river through sinkholes and shafts. Nitrate transport in the karst aquifer system could be ideally divided into three phases, including input storage, fast output and re-inputting storage. Under similar external conditions, the karstification intensity of vadose zone was the key factor to determine the dynamics of nitrate concentrations in the groundwater during storm events. Nitrate stored in the karst vadose zone was easily released, which would impair the aquatic ecosystem and pose seriously threats to the local health. Thus, to strengthen the management of ecological system, changing the land-use patterns and scientifically applying fertilizer could effectively make a contribution to controlling mass nutrient input from the surface.
Santoro, Karin; Maghenzani, Marco; Chiabrando, Valentina; Gullino, Maria Lodovica; Giacalone, Giovanna
2018-01-01
The effect of biofumigation, through slow-release diffusors, of thyme and savory essential oils (EO), was evaluated on the control of postharvest diseases and quality of peaches and nectarines. EO fumigation was effective in controlling postharvest rots. Naturally contaminated peaches and nectarines were exposed to EO vapors for 28 days at 0 °C in sealed storage cabinets and then exposed at 20 °C for five days during shelf-life in normal atmosphere, simulating retail conditions. Under low disease pressure, most treatments significantly reduced fruit rot incidence during shelf-life, while, under high disease pressure, only vapors of thyme essential oil at the highest concentration tested (10% v/v in the diffusor) significantly reduced the rots. The application of thyme or savory EO favored a reduction of brown rot incidence, caused by Monilinia fructicola, but increased gray mold, caused by Botrytis cinerea. In vitro tests confirmed that M. fructicola was more sensitive to EO vapors than B. cinerea. Essential oil volatile components were characterized in storage cabinets during postharvest. The antifungal components of the essential oils increased during storage, but they were a low fraction of the volatile organic compounds in storage chambers. EO vapors did not influence the overall quality of the fruit, but showed a positive effect in reducing weight loss and in maintaining ascorbic acid and carotenoid content. The application of thyme and savory essential oil vapors represents a promising tool for reducing postharvest losses and preserving the quality of peaches and nectarines. PMID:29303966
Santoro, Karin; Maghenzani, Marco; Chiabrando, Valentina; Bosio, Pietro; Gullino, Maria Lodovica; Spadaro, Davide; Giacalone, Giovanna
2018-01-05
The effect of biofumigation, through slow-release diffusors, of thyme and savory essential oils (EO), was evaluated on the control of postharvest diseases and quality of peaches and nectarines. EO fumigation was effective in controlling postharvest rots. Naturally contaminated peaches and nectarines were exposed to EO vapors for 28 days at 0 °C in sealed storage cabinets and then exposed at 20 °C for five days during shelf-life in normal atmosphere, simulating retail conditions. Under low disease pressure, most treatments significantly reduced fruit rot incidence during shelf-life, while, under high disease pressure, only vapors of thyme essential oil at the highest concentration tested (10% v / v in the diffusor) significantly reduced the rots. The application of thyme or savory EO favored a reduction of brown rot incidence, caused by Monilinia fructicola , but increased gray mold, caused by Botrytis cinerea . In vitro tests confirmed that M. fructicola was more sensitive to EO vapors than B. cinerea . Essential oil volatile components were characterized in storage cabinets during postharvest. The antifungal components of the essential oils increased during storage, but they were a low fraction of the volatile organic compounds in storage chambers. EO vapors did not influence the overall quality of the fruit, but showed a positive effect in reducing weight loss and in maintaining ascorbic acid and carotenoid content. The application of thyme and savory essential oil vapors represents a promising tool for reducing postharvest losses and preserving the quality of peaches and nectarines.
Blagojević, Polina D; Radulović, Niko S; Skropeta, Danielle
2015-08-01
The plant volatile profile and the essential-oil chemical composition change during the storage of plant material. The objective of this study was to develop a mathematical model able to predict, explain, and quantify these changes. Mathematical equations, derived under the assumption that the essential oil contained within plant material could be treated as an ideal solution (Raoult's law), were applied for tracking of postharvest changes in the volatile profile of Artemisia absinthium L. (the essential oils were analyzed by GC-FID and GC/MS). Starting from a specific chemical composition of an essential-oil sample obtained from plant material after a short drying period (typically 5-10 d), and by using the equations derived from this model, one could easily predict evaporation-induced changes in the volatile profile of the plant material. Based on the composition of the essential-oil sample obtained after a given storage time t, it is possible to identify those components that were involved in chemical reactions, both as reactants and possible products. The established model even allowed the recognition of pairs of transformation, i.e., 'daughter' products and their 'parent' compounds. The obtained results highlight that the essential-oil composition is highly dependent on the storage period of any plant material and urges caution in different types of phytochemical studies, especially chemotaxonomic ones, or practical application. Copyright © 2015 Verlag Helvetica Chimica Acta AG, Zürich.
75 FR 57754 - Combined Notice of Filings No. 2
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-22
... Refund Report filings: Docket Numbers: RP10-1258-001. Applicants: Central New York Oil and Gas Co., LLC. Description: Central New York Oil and Gas Company, LLC submits their compliance filing to incorporate in the...-001. Applicants: Arlington Storage Company, LLC. Description: Arlington Storage Company, LLC submits...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Barnes, David A.; Harrison, William B.
The Michigan Geological Repository for Research and Education (MGRRE), part of the Department of Geosciences at Western Michigan University (WMU) at Kalamazoo, Michigan, established MichCarb—a geological carbon sequestration resource center by: • Archiving and maintaining a current reference collection of carbon sequestration published literature • Developing statewide and site-specific digital research databases for Michigan’s deep geological formations relevant to CO2 storage, containment and potential for enhanced oil recovery • Producing maps and tables of physical properties as components of these databases • Compiling all information into a digital atlas • Conducting geologic and fluid flow modeling to address specific predictivemore » uses of CO2 storage and enhanced oil recovery, including compiling data for geological and fluid flow models, formulating models, integrating data, and running the models; applying models to specific predictive uses of CO2 storage and enhanced oil recovery • Conducting technical research on CO2 sequestration and enhanced oil recovery through basic and applied research of characterizing Michigan oil and gas and saline reservoirs for CO2 storage potential volume, injectivity and containment. Based on our research, we have concluded that the Michigan Basin has excellent saline aquifer (residual entrapment) and CO2/Enhanced oil recovery related (CO2/EOR; buoyant entrapment) geological carbon sequestration potential with substantial, associated incremental oil production potential. These storage reservoirs possess at least satisfactory injectivity and reliable, permanent containment resulting from associated, thick, low permeability confining layers. Saline aquifer storage resource estimates in the two major residual entrapment, reservoir target zones (Lower Paleozoic Sandstone and Middle Paleozoic carbonate and sandstone reservoirs) are in excess of 70-80 Gmt (at an overall 10% storage efficiency factor; an approximately P50 probability range for all formations using DOE-NETL, 2010, storage resource estimation methodology). Incremental oil production resulting from successful implementation of CO2/EOR for the highest potential Middle Paleozoic reef reservoirs (Silurian, Northern Niagaran Reef trend) in Michigan is estimated at 130 to over 200 MMBO (22-33 Mm3). In addition, between 200 and 400 Mmt of CO2 could be sequestered in the course of successful deployment of CO2/EOR in the northern reef trend’s largest depleted (primary production) oil fields (those that have produced in excess of 500,000 BO; 80,000 m3of oil). • Effecting technology transfer to members of industry and governmental agencies by establishing an Internet Website at which all data, reports and results are accessible; publishing results in relevant journals; conducting technology transfer workshops as part of our role as the Michigan Center of the Petroleum Technology Transfer Council or any successor organization.« less
Alikhani-Koupaei, Majid; Mazlumzadeh, Meisam; Sharifani, Mohamadmehdi; Adibian, Mohamad
2014-01-01
Fresh button mushrooms (Agaricus bisporus L.) are sensitive to browning, water loss, and microbial attack. The short shelf-life of mushrooms is an impediment to the distribution and marketing of the fresh product. Essential oils outstand as an alternative to chemical preservatives and their use in foods meets the demands of consumers for natural products. To resolve controlled release of oil and increase in antioxidant and antimicrobial activities, the oil was incorporated into microcapsules. Effects of microcapsulated thyme (Thymus vulgaris L.) and rosemary (Rosmarinus officinalis L.) on quality of fresh button mushroom were compared. Physicochemical qualities were evaluated during 15 days of storage at 4 ± 0.5°C. All treatments prevented product weight loss and decrease in polyphenoloxidase and peroxidase activities during storage. Color and firmness, microbiological analysis, and total phenolic content caused the least change. With use of microencapsulated oils, mushrooms were within acceptable limits during 10 days of storage. Microencapsulated rosemary oil produced the highest beneficial effects and has potential to improve quality of button mushrooms and extend shelf-life. PMID:25473510
Leong, Mei-Huan; Tan, Chin-Ping; Nyam, Kar-Lin
2016-10-01
The objective of this research was to study the oxidative stability and antioxidant properties of microencapsulated kenaf (Hibiscus cannabinus L.) seed oil (MKSO) produced by co-extrusion technology upon accelerated storage. The combination of sodium alginate, high methoxyl pectin, and chitosan were used as shell materials. The oxidative stability of the kenaf seed oil was determined by iodine value, peroxide value, p-Anisidine value, total oxidation (TOTOX), thiobarbituric acid reactive substances assay, and free fatty acid content. Total phenolic content, 2,2'-azino-bis(3-ethylbenzothiazoline-6-sulphonic acid) cation radical-scavenging assay and 2,2-diphenyl-1-picrylhydrazyl radical scavenging assay were used to examine the antioxidant properties of oils. Oxidative stability tests showed that bulk kenaf seed oil (BKSO) was oxidized significantly higher (P < 0.05) than MKSO. The total increment of TOTOX value of BKSO was 165.93% significantly higher (P < 0.05) than MKSO. Co-extrusion technology has shown to be able to protect kenaf seed oil against lipid oxidation and delay the degradation of natural antioxidants that present in oil during storage. © 2016 Institute of Food Technologists®.
Dwyer, Sandra P O'; O'Beirne, David; Ní Eidhin, Deirdre; O'Kennedy, Brendan T
2012-12-01
This study examined the effectiveness of fat and water soluble antioxidants on the oxidative stability of omega (ω)-3 rich table spreads, produced using novel multiple emulsion technology. Table spreads were produced by dispersing an oil-in-water (O/W) emulsion (500 g/kg 85 camelina/15 fish oil blend) in a hardstock/rapeseed oil blend, using sodium caseinate and polyglycerol polyricinoleate as emulsifiers. The O/W and oil-in-water-in-oil (O/W/O) emulsions contained either a water soluble antioxidant (green tea extract [GTE]), an oil soluble antioxidant (α-Tocopherol), or both. Spreads containing α-Tocopherol had the highest lipid hydroperoxide values, whereas spreads containing GTE had the lowest (P < 0.05), during storage at 5°C, while p-Anisidine values did not differ significantly. Particle size was generally unaffected by antioxidant type (P < 0.05). Double emulsion (O/W/O) structures were clearly seen in confocal images of the spreads. By the end of storage, none of the spreads had significantly different G' values. Firmness (Newtons) of all spreads generally increased during storage (P < 0.05). © 2012 Institute of Food Technologists®
IN VITRO CYTOTOXICITY OF BTEX METABOLITES IN HELA CELL LINES
Fuel leakage from underground storage tanks is a major source of groundwater contamination. Although the toxicity of regulated compounds such as benzene, toluene, ethylbenzene, and xylene (BTEX) are well recognized, the cytotoxicity of their metabolites has not been studied exte...
30 CFR 57.4430 - Surface storage facilities.
Code of Federal Regulations, 2010 CFR
2010-07-01
....4430 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention... ignition sources to prevent fire or explosion; and (4) Vented or otherwise constructed to prevent...
Read about a former underground storage tank site fronting on the Little Tennessee River in Franklin, NC that is now reused as an attractive greenspace with parking and Main Street access to the Nikwasi Mound.
With assistance from the Association of State and Territorial Air and Solid Waste Management Officials (ASTSWMO), the U.S. EPA Office of Underground Storage Tanks (OUST) and the U.S. EPA Office of Research and Development (ORD) conducted a survey to determine the distribution of ...
Report to Congress on a Compliance Plan for the Underground Storage Tank Program
Learn about identification of USTs that are not in compliance with Subtitle I of the Solid Waste Disposal Act or are in temporary closure, and determine the ownership of USTs not in compliance or in temporary closure
40 CFR 280.33 - Repairs allowed.
Code of Federal Regulations, 2013 CFR
2013-07-01
... recognized association or an independent testing laboratory. Note: The following codes and standards may be used to comply with paragraph (a) of this section: National Fire Protection Association Standard 30... Practice for the Interior Lining of Existing Steel Underground Storage Tanks”; and National Leak Prevention...
40 CFR 280.33 - Repairs allowed.
Code of Federal Regulations, 2012 CFR
2012-07-01
... recognized association or an independent testing laboratory. Note: The following codes and standards may be used to comply with paragraph (a) of this section: National Fire Protection Association Standard 30... Practice for the Interior Lining of Existing Steel Underground Storage Tanks”; and National Leak Prevention...
40 CFR 280.33 - Repairs allowed.
Code of Federal Regulations, 2014 CFR
2014-07-01
... recognized association or an independent testing laboratory. Note: The following codes and standards may be used to comply with paragraph (a) of this section: National Fire Protection Association Standard 30... Practice for the Interior Lining of Existing Steel Underground Storage Tanks”; and National Leak Prevention...
Report #11-R-0018, November 22, 2010. While the Recovery Act grants we reviewed contained most of the requirements specified in Agency regulations and guidance, there were three management control deficiencies with these grants.
EPA guidance on complying with the federal compatibility requirement for underground storage tank (UST) systems storing gasoline containing greater than 10 percent ethanol or diesel containing greater than 20 percent biodiesel.
78 FR 48639 - North Dakota Underground Injection Control Program Revision Application
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-09
... Dakota Industrial Commission, Oil and Gas Division 1016 East Calgary Avenue, Bismarck, North Dakota 58503... the North Dakota Industrial Commission (NDIC) to issue UIC permits for carbon geo-sequestration... protected through www.regulations.gov or email. The www.regulations.gov Web site is an ``anonymous access...
NASA Astrophysics Data System (ADS)
Falta, R. W.
2004-05-01
Ethylene dibromide (EDB) is a synthetic organic chemical that was produced in large amounts for use as a leaded gasoline additive and pesticide. The chlorinated solvent 1,2-dichlorethane (1,2-DCA) is widely used in the chemical industry, and was also added to leaded gasoline. EDB and 1,2-DCA are classified as probable human carcinogens by the United States Environmental Protection Agency (EPA), and EDB's use as a pesticide was suspended in 1984. The current EPA maximum contaminant level (MCL) for EDB in drinking water is 0.05 ug/l, and the MCL for 1,2-DCA is 5 ug/l. EDB has proven to be both mobile and persistent in groundwater, and contamination of groundwater by EDB was documented in several states beginning in the early 1980s. The majority of this contamination is attributed to agricultural uses of EDB, however approximately 90 percent of the EDB produced was used as a leaded gasoline additive, and it was present in virtually all leaded gasoline sold in the US. 1,2-DCA is commonly found as a groundwater contaminant, and it is both mobile and persistent. Past site investigations and remediation efforts at underground storage tank sites contaminated by leaded gasoline have rarely addressed the potential for EDB or 1,2-DCA contamination. However, the concentrations of EDB and 1,2-DCA in leaded gasoline were high enough to produce groundwater concentrations of thousands of ug/l. For this reason, there is a substantial likelihood that undetected EDB and 1,2-DCA plumes above the MCL may exist at many sites where leaded gasoline leaked or spilled. An initial review of field data from underground storage tank sites in two states suggests that this problem is widespread.