Sample records for underground water supplies

  1. Detection of underground water distribution piping system and leakages using ground penetrating radar (GPR)

    NASA Astrophysics Data System (ADS)

    Amran, Tengku Sarah Tengku; Ismail, Mohamad Pauzi; Ahmad, Mohamad Ridzuan; Amin, Mohamad Syafiq Mohd; Sani, Suhairy; Masenwat, Noor Azreen; Ismail, Mohd Azmi; Hamid, Shu-Hazri Abdul

    2017-01-01

    A water pipe is any pipe or tubes designed to transport and deliver water or treated drinking with appropriate quality, quantity and pressure to consumers. The varieties include large diameter main pipes, which supply entire towns, smaller branch lines that supply a street or group of buildings or small diameter pipes located within individual buildings. This distribution system (underground) is used to describe collectively the facilities used to supply water from its source to the point of usage. Therefore, a leaking in the underground water distribution piping system increases the likelihood of safe water leaving the source or treatment facility becoming contaminated before reaching the consumer. Most importantly, leaking can result in wastage of water which is precious natural resources. Furthermore, they create substantial damage to the transportation system and structure within urban and suburban environments. This paper presents a study on the possibility of using ground penetrating radar (GPR) with frequency of 1GHz to detect pipes and leakages in underground water distribution piping system. Series of laboratory experiment was designed to investigate the capability and efficiency of GPR in detecting underground pipes (metal and PVC) and water leakages. The data was divided into two parts: 1. detecting/locating underground water pipe, 2. detecting leakage of underground water pipe. Despite its simplicity, the attained data is proved to generate a satisfactory result indicating GPR is capable and efficient, in which it is able to detect the underground pipe and presence of leak of the underground pipe.

  2. [Arsenic levels in drinking water supplies from underground sources in the community of Madrid].

    PubMed

    Aragonés Sanz, N; Palacios Diez, M; Avello de Miguel, A; Gómez Rodríguez, P; Martínez Cortés, M; Rodríguez Bernabeu, M J

    2001-01-01

    In 1998, arsenic concentrations of more than 50 micrograms/l were detected in some drinking water supplies from underground sources in the Autonomous Community of Madrid, which is the maximum permissible concentration for drinking water in Spain. These two facts have meant the getting under way of a specific plan for monitoring arsenic in the drinking water in the Autonomous Community of Madrid. The results of the first two sampling processes conducted in the arsenic level monitoring plan set out are presented. In the initial phase, water samples from 353 water supplies comprised within the census of the Public Health Administration of the Autonomous Community of Madrid were analyzed. A water supply risk classification was made based on these initial results. In a second phase, six months later, the analyses were repeated on those 35 water supplies which were considered to possibly pose a risk to public health. Seventy-four percent (74%) of the water supplies studied in the initial phase were revealed to have an arsenic concentration of less than 10 micrograms/l, 22.6% containing levels of 10 micrograms/l-50 micrograms/l, and 3.7% over 50 micrograms/l. Most of the water supplies showing arsenic levels of more than 10 micrograms/l are located in the same geographical area. In the second sampling process (six months later), the 35 water supplies classified as posing a risk were included. Twenty-six (26) of these supplies were revealed to have the same arsenic level ((10-50 micrograms/l), and nine changed category, six of which had less than 10 micrograms/l and three more than 50 micrograms/l. In the Autonomous Community of Madrid, less than 2% of the population drinks water coming from supplies which are from underground sources. The regular water quality monitoring conducted by the Public Health Administration has led to detecting the presence of more than 50 micrograms/l of arsenic in sixteen drinking water supplies from underground sources, which is the maximum permissible level under the laws currently in force in Spain. Measures have been taken to prevent water from being used from these water supplies. Around 20% of the water supplies studies must take measures in the near future to lower the arsenic concentration to below 10 micrograms/l when the water directive which is currently in the process of being written into Spanish law enters into effect.

  3. An outbreak of norovirus gastroenteritis associated with a secondary water supply system in a factory in south China.

    PubMed

    Li, Yuan; Guo, Hongxiong; Xu, Zhenghui; Zhou, Xiaotao; Zhang, Hailong; Zhang, Lijie; Miao, Jing; Pan, Yi

    2013-03-28

    Between September 17 and October 3, 2009, hundreds of workers employed in a manufacturing factory in Shenzhen, a city in south China developed a sudden onset of acute gastroenteritis. A retrospective cohort study is designed to identify the risk factors and control this outbreak. Information on demographic characteristics, working place, the history of contact with a person having diarrhea and/or vomiting, drink water preference and frequency, eating in the company cafeteria or outside the company, hand-washing habits and eating habits is included. Furthermore, in order to find the contamination source, we investigated the environment around the underground reservoir and collected water samples from the junction between municipal supply water system and underground reservoir to test potential bacteria and virus, examine the seepage tracks on the wall of the underground reservoir from the side of septic tank, and check the integrity and attitude of this lid. Relative risk was presented and Chi-square test was performed. All the analyses were performed with OpenEpi software version 2.3.1 online. The cohort study demonstrated that the workers who had direct drink water were 3.0 fold more likely to suffer from acute gastroenteritis than those who consumed commercial bottled water. The direct drinking water, water of the tank of buildings, and the underground reservoir were positive only for norovirus. Norovirus was also detected from stool and rectal swab samples from patients with acute gastroenteritis. The underground reservoir was found to be the primary contamination source. Further environmental investigation showed that the norovirus contaminated substance entered into the underground reservoir via access holes in lid covering this underground reservoir. This acute gastroenteritis outbreak was caused by the secondary supply system contaminated by norovirus in this factory. The outbreak of gastroenteritis cases caused by norovirus frequently occurred in China due to a lack of surveillance and supervision, and due to faults in the construction of such water systems. Therefore, more attentions should pay to the secondary supply water system in China.

  4. An outbreak of norovirus gastroenteritis associated with a secondary water supply system in a factory in south China

    PubMed Central

    2013-01-01

    Background Between September 17 and October 3, 2009, hundreds of workers employed in a manufacturing factory in Shenzhen, a city in south China developed a sudden onset of acute gastroenteritis. A retrospective cohort study is designed to identify the risk factors and control this outbreak. Methods Information on demographic characteristics, working place, the history of contact with a person having diarrhea and/or vomiting, drink water preference and frequency, eating in the company cafeteria or outside the company, hand-washing habits and eating habits is included. Furthermore, in order to find the contamination source, we investigated the environment around the underground reservoir and collected water samples from the junction between municipal supply water system and underground reservoir to test potential bacteria and virus, examine the seepage tracks on the wall of the underground reservoir from the side of septic tank, and check the integrity and attitude of this lid. Relative risk was presented and Chi-square test was performed. All the analyses were performed with OpenEpi software version 2.3.1 online. Results The cohort study demonstrated that the workers who had direct drink water were 3.0 fold more likely to suffer from acute gastroenteritis than those who consumed commercial bottled water. The direct drinking water, water of the tank of buildings, and the underground reservoir were positive only for norovirus. Norovirus was also detected from stool and rectal swab samples from patients with acute gastroenteritis. The underground reservoir was found to be the primary contamination source. Further environmental investigation showed that the norovirus contaminated substance entered into the underground reservoir via access holes in lid covering this underground reservoir. Conclusion This acute gastroenteritis outbreak was caused by the secondary supply system contaminated by norovirus in this factory. The outbreak of gastroenteritis cases caused by norovirus frequently occurred in China due to a lack of surveillance and supervision, and due to faults in the construction of such water systems. Therefore, more attentions should pay to the secondary supply water system in China. PMID:23537289

  5. Bibliography of Ground-Water References for All 254 Counties in Texas, 1886-2001

    DTIC Science & Technology

    2005-01-01

    ATLAS FOR BAILEY COUNTY, TEXAS: HIGH PLAINS UNDERGROUND WATER CONSERVATION DISTRICT NO. 1, 1987. HYDROGEOLOGY AND HYDROCHEMISTRY OF CRETACEOUS AQUI- FERS... UNDERGROUND WATER CONSERVATION DISTRICT NO. 1, 1987. HYDROGEOLOGY AND HYDROCHEMISTRY OF CRETACEOUS AQUI- FERS, TEXAS PANHANDLE AND EASTERN NEW MEXICO: UNI...Counties in Texas, 1886–2001 Compiled By E.T. Baker, Jr. ANDERSON COUNTY UNDERGROUND WATERS OF THE COASTAL PLAIN OF TEXAS: USGS WATER -SUPPLY PAPER 190

  6. GIS Analysis of Available Data to Identify regions in the U.S. Where Shallow Ground Water Supplies are Particularly Vulnerable to Contamination by Releases to Biofuels from Underground Storage Tanks

    EPA Science Inventory

    GIS analysis of available data to identify regions in the U.S. where shallow ground water supplies are particularly vulnerable to contamination by releases of biofuels from underground storage tanks. In this slide presentation, GIS was used to perform a simple numerical and ...

  7. 30 CFR 75.1107-8 - Fire suppression devices; extinguishant supply systems.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Fire suppression devices; extinguishant supply systems. (a) Fire suppression systems using water or... equivalent protective devices and a rising stem or other visual indicator-type shutoff valve. (b) Water supplies for fire suppression devices installed on underground equipment may be maintained in mounted water...

  8. 30 CFR 75.1107-8 - Fire suppression devices; extinguishant supply systems.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Fire suppression devices; extinguishant supply systems. (a) Fire suppression systems using water or... equivalent protective devices and a rising stem or other visual indicator-type shutoff valve. (b) Water supplies for fire suppression devices installed on underground equipment may be maintained in mounted water...

  9. 30 CFR 75.1107-8 - Fire suppression devices; extinguishant supply systems.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Fire suppression devices; extinguishant supply systems. (a) Fire suppression systems using water or... equivalent protective devices and a rising stem or other visual indicator-type shutoff valve. (b) Water supplies for fire suppression devices installed on underground equipment may be maintained in mounted water...

  10. 30 CFR 75.1101-3 - Water requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Water requirements. 75.1101-3 Section 75.1101-3... MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1101-3 Water requirements. Deluge-type water spray systems shall be attached to a water supply. Water so supplied shall be free of...

  11. 30 CFR 75.1101-3 - Water requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Water requirements. 75.1101-3 Section 75.1101-3... MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1101-3 Water requirements. Deluge-type water spray systems shall be attached to a water supply. Water so supplied shall be free of...

  12. 30 CFR 75.1101-3 - Water requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Water requirements. 75.1101-3 Section 75.1101-3... MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1101-3 Water requirements. Deluge-type water spray systems shall be attached to a water supply. Water so supplied shall be free of...

  13. 30 CFR 75.1101-3 - Water requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Water requirements. 75.1101-3 Section 75.1101-3... MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1101-3 Water requirements. Deluge-type water spray systems shall be attached to a water supply. Water so supplied shall be free of...

  14. 30 CFR 75.1101-3 - Water requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Water requirements. 75.1101-3 Section 75.1101-3... MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1101-3 Water requirements. Deluge-type water spray systems shall be attached to a water supply. Water so supplied shall be free of...

  15. CONTAMINATION OF PUBLIC GROUND WATER SUPPLIES BY SUPERFUND SITES

    EPA Science Inventory

    Multiple sources of contamination can affect ground water supplies, including municipal landfills, industrial operations, leaking underground storage tanks, septic tank systems, and prioritized uncontrolled hazardous waste sites known as “Superfund” sites. A review of Superfund R...

  16. Using Geographical Information Systems (GIS) to Identify the Geographic Regions Where People That Use Ground Water are Most Vulnerable to Impacts from Underground Storage

    EPA Science Inventory

    Using Geographic Information Systems (GIS), the vulnerability of ground water supplies to contamination from underground storage tanks (USTs) was assessed. The analysis was conducted for the 48 contiguous states, and then again for groups of states corresponding to the EPA Regio...

  17. 30 CFR 75.1107-7 - Water spray devices; capacity; water supply; minimum requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Water spray devices; capacity; water supply; minimum requirements. 75.1107-7 Section 75.1107-7 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection Fire Suppression Devices and...

  18. 30 CFR 75.1107-7 - Water spray devices; capacity; water supply; minimum requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Water spray devices; capacity; water supply; minimum requirements. 75.1107-7 Section 75.1107-7 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection Fire Suppression Devices and...

  19. 30 CFR 75.1107-7 - Water spray devices; capacity; water supply; minimum requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Water spray devices; capacity; water supply; minimum requirements. 75.1107-7 Section 75.1107-7 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection Fire Suppression Devices and...

  20. 30 CFR 75.1107-7 - Water spray devices; capacity; water supply; minimum requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Water spray devices; capacity; water supply; minimum requirements. 75.1107-7 Section 75.1107-7 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection Fire Suppression Devices and...

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Elliott, G.R.B.; Vanderborgh, N.E.

    Experimental and theoretical analyses show that uncontrolled water invasion during underground coal conversion (UCC) is harmful at all stages of UCC. By contrast, if water invasion is prevented, coal porosity can be created for further processing, pyrolysis can yield uniform hydrocarbon products, gasification can produce a uniform product, coal is fully consumed (not bypassed) during combustion, and environmental problems are minimized. In all cases the experimental results are supportive of the theory of underground coal processing presented. We see no insurmountable technical problems existing for a staged underground coal conversion process, but we emphasize that all concepts in underground coalmore » processing depend critically upon control of water influx. It is important that techniques for measuring and controlling water flow be developed if this technology is to make a contribution to the Nation's energy supply.« less

  2. Three dimensional display of underground water-supplying network by combining VTK with SiCAD/open GIS system

    NASA Astrophysics Data System (ADS)

    Chen, Shaobin; Zhang, Xubo; Wang, Wenyuan; Zhou, Chengping; Ding, Mingyue

    2007-11-01

    Nowadays many Geographic Information System (GIS) have been widely used in many municipal corporations. Water-supplying corporations in many cities developed GIS application system based on SiCAD/Open GIS platform several years ago for their daily management and engineering construction. With the increasing of commercial business, many corporations now need to add the functionality of three dimensional to display to their GIS System without too much financial cost. Because of the expensiveness of updating SiCAD/Open GIS system to the up-to-date version, the introduction of a third-part 3D display technology is considered. In our solution, Visualization Toolkit (VTK) is used to achieve three dimensional display of underground water-supplying network on the basis of an existing SiCAD/Open GIS system. This paper addresses on the system architecture and key implementation technologies of this solution.

  3. Feasibility study of rainwater harvesting for domestic use (Case study: West Jakarta rainfall data)

    NASA Astrophysics Data System (ADS)

    Kartolo, Jason; Kusumawati, Elly

    2017-11-01

    Rainwater Harvesting system is one of considerable choice to reduce flood in Jakarta, moreover it helps to reduce main tap water consumption. In this study, rainwater is used for flushing toilet and watering garden for domestic use. Rainwater harvesting system is examined for 60 m2 and 90 m2 housing area, using rainfall data from Cengkareng station in West Jakarta. Two type of rainwater harvesting reservoir is designed, those are ground reservoir and underground reservoir. From the analysis, it finds that 60 m2 house feasible for 1 m3 ground reservoir and 9 m3 underground reservoir. Meanwhile for 90 m2 house 2 m3 tanks ground reservoir and 14 m3 tank underground reservoir is feasible. Underground reservoir retain more water volume so it provide higher rate of water supply. The cost of underground reservoir is lower 60% - 70% than ground reservoir. Even though rainwater harvesting is technically feasible for housing, it is not economically feasible. The construction cost is higher than the benefit of reduced tap water consumption.

  4. Groundwater-quality data associated with abandoned underground coal mine aquifers in West Virginia, 1973-2016: Compilation of existing data from multiple sources

    USGS Publications Warehouse

    McAdoo, Mitchell A.; Kozar, Mark D.

    2017-11-14

    This report describes a compilation of existing water-quality data associated with groundwater resources originating from abandoned underground coal mines in West Virginia. Data were compiled from multiple sources for the purpose of understanding the suitability of groundwater from abandoned underground coal mines for public supply, industrial, agricultural, and other uses. This compilation includes data collected for multiple individual studies conducted from July 13, 1973 through September 7, 2016. Analytical methods varied by the time period of data collection and requirements of the independent studies.This project identified 770 water-quality samples from 294 sites that could be attributed to abandoned underground coal mine aquifers originating from multiple coal seams in West Virginia.

  5. Design Improvements in Underground Watering System for Small Local Farming Industries

    NASA Astrophysics Data System (ADS)

    Ariff, T. F.; Tukiman, N. H. A.; Bahar, R.

    2016-02-01

    The implementation of underground watering system is basically to supply crops with enough quantities of water. In Malaysia, most farming industries use sprinkler irrigation system. The water is only distributed over the surface whilst the roots actually need water the most. Thus, this research is conducted to design the improvements of watering system for small local farming industries by using underground watering system. Design improvements of the watering system had been done using CATIA software. The design had been fabricated using rapid prototyping/3D printer, tested and evaluated by conducting experiments. Four different plants were prepared and labelled as Plant A, Plant B, Plant C, and Plant D. Plant A and Plant C were not be equipped with the underground watering device while Plant B and Plant D were equipped with the device. The growth of every plant is measured in terms of height, number of newly grown leaves, number of flowers and number of fruits for the duration of 60 days. The plant equipped with the device has the quickest growth measurement (59.68%), continued to produce new leaves rapidly (89.20%), and produced the most number of flowers (19 flowers) and fruits (15 fruits) when compared with the plants without the underground watering device. The difference in growth development is very significant. Therefore, the underground watering system does have a positive impact in nourishing the plant from the root efficiently and can be used productively in small local farming industries.

  6. 30 CFR 75.1718 - Drinking water.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Drinking water. 75.1718 Section 75.1718 Mineral... SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1718 Drinking water. [Statutory Provisions] An adequate supply of potable water shall be provided for drinking purposes in the active workings of the mine...

  7. 30 CFR 75.1718 - Drinking water.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Drinking water. 75.1718 Section 75.1718 Mineral... SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1718 Drinking water. [Statutory Provisions] An adequate supply of potable water shall be provided for drinking purposes in the active workings of the mine...

  8. 30 CFR 75.1718 - Drinking water.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Drinking water. 75.1718 Section 75.1718 Mineral... SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1718 Drinking water. [Statutory Provisions] An adequate supply of potable water shall be provided for drinking purposes in the active workings of the mine...

  9. 30 CFR 75.1718 - Drinking water.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Drinking water. 75.1718 Section 75.1718 Mineral... SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1718 Drinking water. [Statutory Provisions] An adequate supply of potable water shall be provided for drinking purposes in the active workings of the mine...

  10. 30 CFR 75.1718 - Drinking water.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Drinking water. 75.1718 Section 75.1718 Mineral... SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1718 Drinking water. [Statutory Provisions] An adequate supply of potable water shall be provided for drinking purposes in the active workings of the mine...

  11. 40 CFR 192.01 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Administrator of the Environmental Protection Agency. (i) Secretary means the Secretary of Energy. (j... water below the ground surface in a zone of saturation. (r) Underground source of drinking water means... system; and (A) Currently supplies drinking water for human consumption; or (B) Contains fewer than 10...

  12. 40 CFR 192.01 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Administrator of the Environmental Protection Agency. (i) Secretary means the Secretary of Energy. (j... water below the ground surface in a zone of saturation. (r) Underground source of drinking water means... system; and (A) Currently supplies drinking water for human consumption; or (B) Contains fewer than 10...

  13. School Kicks the Oil Habit.

    ERIC Educational Resources Information Center

    American School and University, 1981

    1981-01-01

    Underground geothermal water from an artesian well supplies heat for rural Haakon School District in Philip (South Dakota). The same water is then piped to the downtown business district a few blocks away and sold as fuel to participating merchants. (Author/MLF)

  14. Hydroperiod enhancement using underground pipes for the efficient removal of hypersaline conditions in a semiarid coastal lagoon

    NASA Astrophysics Data System (ADS)

    Flores-Verdugo, Francisco; Ramírez-Barrón, Eduardo; Flores-de-Santiago, Francisco

    2018-06-01

    Pore-water hypersaline conditions are common in semiarid coastlines where freshwater availability is limited. Hence, hydroperiod (or flood regime), contributes to the regular supply of new water enhancing mangrove survival and growth. The purpose of this investigation was to assess pore-water salinity and hydroperiod variability of basin mangrove distribution by installing three underground PVC (polyvinyl chloride) pipes connected to the main tidal channel. All pipes were placed perpendicular to the main channel for an annual cycle. Results indicated hydroperiod enhancement at the location of the underground pipes, compared to control stations. Overall, spring tides and rainy season played a key role in temporal hydroperiod variability. Indeed, the interior structure of the pipes allows rapid and continuous intrusion of new water into the saltpan during flood and ebb currents. After three months, pore-water salinity of 170 in the saltpan area was reduced to 80 at a distance of 2 m from the underground pipes. This study shows the applicability of underground pipes for the efficient removal of hypersaline conditions by enhancing tidal flow for possible recruitment of mangrove propagules in semiarid coastlines.

  15. Current (2004-07) Conditions and Changes in Ground-Water Levels from Predevelopment to 2007, Southern High Plains Aquifer, Southeast New Mexico-Lea County Underground Water Basin

    USGS Publications Warehouse

    Tillery, Anne

    2008-01-01

    The Southern High Plains aquifer is the principal aquifer and primary source of water in southeastern New Mexico. The Lea County portion of the aquifer covers approximately the northern two thirds of the 4,393-square-mile county. Successful water-supply planning for New Mexico's Southern High Plains requires knowledge of the current aquifer conditions and a context from which to estimate future trends given current aquifer-management policy. Maps representing water-level declines, current (2007) water levels, aquifer saturated thickness, and depth to water accompanied by hydrographs from representative wells for the Southern High Plains aquifer in the Lea County Underground Water Basin were prepared in cooperation with the New Mexico Office of the State Engineer. Results of this mapping effort show the water level has declined as much as 97 feet in the Lea County Underground Water Basin from predevelopment (1914-54) to 2007 with rates as high as 0.88 feet per year.

  16. REDUCTION IN DBP PRECURSORS AND PATHOGENS DURING RIVERBANK FILTRATION AT THREE MIDWESTERN DRINKING WATER UTILITIES

    EPA Science Inventory

    Riverbank filtrtion (RBF) is a process that subjects river water to ground passage prior to its use as a drinking water supply. European expereince with RBF demonstrate that during infiltration and underground transport, processes such as filtration, sorption, and biodegradation...

  17. Feasibility study of rainwater harvesting system in Sylhet City.

    PubMed

    Alam, R; Munna, G; Chowdhury, M A I; Sarkar, M S K A; Ahmed, M; Rahman, M T; Jesmin, F; Toimoor, M A

    2012-01-01

    In rural areas in Bangladesh, groundwater is the principal source of water supply. This underground water is available in considerable amount in shallow aquifers. It is free from pathogenic microorganisms and hence water-borne diseases. In plain lands, other than hilly areas, water supply to 97% rural population comes from tube-wells, which is regarded to be a phenomenal achievement in preserving public health. Besides, a dependable water supply system all throughout the country is offset by two factors: (a) high salinity in surface plus groundwater in coastal areas; (b) want of suitable groundwater aquifers in hilly areas and the high cost of setting up tube-wells due to deep underground water table and stony layers. However, presence of arsenic in underground water now poses a serious threat to the success once made in water supply by setting up of manually operated tube-wells in the village areas-the achievement is now on the brink of total collapse. In about 61 districts out of 64, presence of arsenic exceeds a quantity of 0.05 mg/1, a permissible limit as per Bangladeshi water quality standard. Harvesting rainwater can be a pragmatic solution to this problem, which is common in many places in Sylhet especially in the hilly areas on the north eastern part of the city. This can be an alternative source of drinking water because of availability of rainwater from March to October. Heavy rain occurs from end of May till mid September, which is commonly known as the rainy season. This paper focuses on the possibility of harvesting rainwater in rural communities and thickly populated urban areas of Sylhet. It also demonstrates the scopes of harvesting rainwater using simple and low-cost technology. With setting up of a carefully planned rainwater storage tank, a family can have all of its drinking water from rain. Planned use of rainwater through rainwater harvesting in the roof catchments may fulfill the entire annual domestic water demand of a family in the rural areas of Bangladesh.

  18. Hydrology and hydrogeology of Navajo Lake, Kane County, Utah

    USGS Publications Warehouse

    Wilson, Milton Theurer; Thomas, Harold E.

    1964-01-01

    Navajo Lake, whose entire outflow disappears underground, is on the high Markagurit Plateau where the average annual precipitation is more than 30 inches. It nestles among the headwaters of several streams that flow into arid regions where competition for municipal, industrial, and irrigation water sup- plies is very keen. Several proposals for additional development and use of the water of Navajo Lake have led to controversies and raised questions in regard to the total water supply and its disposition, and to the effect of the proposed projects on existing water rights. This report summarizes the results of an investigation of the water supply of Navajo Lake and the present disposition of that supply.

  19. Preliminary evaluation of the Highland Rim aquifer system in Tennessee for receiving injected wastes

    USGS Publications Warehouse

    Bradley, M.W.

    1986-01-01

    The EPA has authority under the Safe Drinking Water Act to protect underground sources of drinking water from contamination by deep well injection. An aquifer, however, may be exempted from protection and used for injected wastes where the aquifer meets criteria established in the Agency 's Underground Injection Control program. The Highland Rim aquifer system in Tennessee consists of Mississippian age carbonate rocks and occurs from the Valley and Ridge of East Tennessee to west of the Tennessee River. This aquifer contains potable water and is an important source of drinking water for municipal and domestic supplies on the Highland Rim. The Highland Rim aquifer system under parts of the Cumberland Plateau is not currently used as a source of drinking water and is not expected to be used in the future. These areas meet parts of the EPA 's Underground Injection Control criteria for exempting aquifers to receive injected waste. (Author 's abstract)

  20. 30 CFR 822.12 - Protection of agricultural activities.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... alluvial valley floors; or (2) cause material damage to the quantity or quality of water in surface or underground water systems that supply alluvial valley floors. (b) Statutory exclusions. The prohibitions of... be of negligible impact on the farm's agricultural production; (3) To any surface coal mining and...

  1. 30 CFR 822.12 - Protection of agricultural activities.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... alluvial valley floors; or (2) cause material damage to the quantity or quality of water in surface or underground water systems that supply alluvial valley floors. (b) Statutory exclusions. The prohibitions of... be of negligible impact on the farm's agricultural production; (3) To any surface coal mining and...

  2. Summary appraisals of the Nation's ground-water resources; Pacific Northwest region

    USGS Publications Warehouse

    Foxworthy, Bruce L.

    1979-01-01

    Management opportunities in the region include: (1) Development of new supplies and additional uses of ground water; (2) protection and enhancement of water quality; (3) reduction of waterlogging; (4) energy development from some ground-water reservoirs; (5) improving access to the ground water; (6) increased use of underground space for storage and disposal; and (7) greater use of advanced management and conservation techniques. Conjunctive use of surface and ground water to provide greater available supplies probably is the most promising water-management opportunity. However, if the full potential of the ground-water resources is to be realized, important constraints, including present water-right structures and serious deficiencies in information, must be overcome.

  3. Preliminary report on the geology and underground water resources of the central Great Plains

    USGS Publications Warehouse

    Darton, N.H.

    1905-01-01

    The area to which this report relates is shown in Pl. II.  It comprises the greater portions of South Dakota, Nebraska, and Kansas, and the eastern portions of Colorado and of Wyoming, an area of about one-half million square miles. It is the result of my investigations during the past eight years, but includes also all available data from many sources. I have been aided by various field assistants, those deserving special mention being Messrs. C. A. Fisher, C. C. O'Harra, J.E. Todd, the late C. M. Hall, G. B. Eichardson, W. S. Tangier Smith, E. H. Barbour, and the late J. E. Macfarland.On account of its size, the region presents relatively diverse geologic conditions, but comprises comparatively few formations, most of which are widespread. The question of water supply, both overground and underground, is one of great interest to the people in this district, and although considerable progress has been made in some sections in developing well waters, there are vast areas in which the present supplies are inadequate, even for local domestic use. In order to understand the relations of the underground waters it has been necessary to investigate the geology, especially the structure and stratigraphy of the water-bearing and associated formations. This part of the work has required a very large amount of special field study, and the present results show that extended investigation will be required before many important questions of geology can be fully understood.

  4. Research on water shortage risks and countermeasures in North China

    NASA Astrophysics Data System (ADS)

    Cheng, Yuxiang; Fang, Wenxuan; Wu, Ziqin

    2017-05-01

    In the paper, a grey forecasting model and a population growth model are established for forecasting water resources supply and demand situation in the region, and evaluating the scarcity of water resources thereof in order to solve the problem of water shortage in North China. A concrete plan for alleviating water resources pressure is proposed with AHP as basis, thereby discussing the feasibility of the plan. Firstly, water resources supply and demand in the future 15 years are predicted. There are four sources for the demand of water resources mainly: industry, agriculture, ecology and resident living. Main supply sources include surface water and underground water resources. A grey forecasting method is adopted for predicting in the paper aiming at water resources demands since industrial, agricultural and ecological water consumption data have excessive decision factors and the correlation is relatively fuzzy. Since residents' water consumption is determined by per capita water consumption and local population, a logistic growth model is adopted to forecast the population. The grey forecasting method is used for predicting per capita water consumption, and total water demand can be obtained finally. International calculation standards are adopted as reference aiming at water supply. The grey forecasting method is adopted for forecasting surface water quantity and underground water quantity, and water resources supply is obtained finally. Per capita water availability in the region is calculated by comparing the water resources supply and demand. Results show that per capita water availability in the region is only 283 cubic meters this year, people live in serious water shortage region, who will suffer from water shortage state for long time. Then, sensitivity analysis is applied for model test. The test result is excellent, and the prediction results are more accurate. In the paper, the following measures are proposed for improving water resources condition in the region according to prediction results, such as construction of reservoirs, sewage treatment, water diversion project and other measures. A detailed water supply plan is formulated. Water supply weights of all measures are determined according to the AHP model. Solution is sought after original models are improved. Results show that water resources quantity per capita will be up to 2170 cubic meters or so this year, people suffer from moderate water shortage in the region, which can meet people's life needs and economic development needs basically. In addition, water resources quantity per capita is increased year by year, and it can reach mild water shortage level after 2030. In a word, local water resources dilemma can be effectively solved by the plan actually, and thoughts can be provided for decision makers.

  5. Efeitos dos sais na planta e tolerância das culturas à salinidade (Salinity effects on plants and tolerance of crops to salinity)

    USDA-ARS?s Scientific Manuscript database

    The major challenge for world agriculture today is to maintain food and water supplies that can meet the demands of a growing world population. The shortage of fresh water, and its use mainly for human consumption, leaves the farmers with the choice of using reclycled city water, or underground sali...

  6. Technogenic effect of liquidation of coal mines on earth’s entrails: hydrogeochemical aspect

    NASA Astrophysics Data System (ADS)

    Tarasenko, I. A.; Zinkov, A. V.; Chudaev, O. V.; Vetoshkina, A. V.; Holodilov, I. I.

    2017-10-01

    The authors of the paper have established the geochemical features of the composition of underground waters and regularities of their formation in the areas of the liquidated coal mines of Russia and Ukraine. It is shown that the mine flood resulted in the formation of technogenic waters which geochemical specificity originates in the feeding field and is transformed in the direction of the filtration flow. It depends on the geological structure of sedimentary basins and the presence in the coal and supra-coal beds of the marine, salt-bearing and freshwater groups of geological formations. The water types are distinguished characterizing the conditions and processes of their formation that may be the regional markers in the hydrochemical and geological constructions. The technogenic waters influenced the safety of the underground waters, sources of water supply of the regions, and surface water channels. The pollutions are of local character in space.

  7. Food and water security issues in Russia II: water security in general population of Russian Arctic, Siberia and Far East, 2000-2011.

    PubMed

    Dudarev, Alexey A; Dushkina, Eugenia V; Sladkova, Yuliya N; Alloyarov, Pavel R; Chupakhin, Valery S; Dorofeyev, Vitaliy M; Kolesnikova, Tatjana A; Fridman, Kirill B; Evengard, Birgitta; Nilsson, Lena M

    2013-01-01

    Poor state of water supply systems, shortage of water purification facilities and disinfection systems, low quality of drinking water generally in Russia and particularly in the regions of the Russian Arctic, Siberia and Far East have been defined in the literature. However, no standard protocol of water security assessment has been used in the majority of studies. Uniform water security indicators collected from Russian official statistical sources for the period 2000-2011 were used for comparison for 18 selected regions in the Russian Arctic, Siberia and Far East. The following indicators of water security were analyzed: water consumption, chemical and biological contamination of water reservoirs of Categories I and II of water sources (centralized--underground and surface, and non-centralized) and of drinking water. Water consumption in selected regions fluctuated from 125 to 340 L/person/day. Centralized water sources (both underground and surface sources) are highly contaminated by chemicals (up to 40-80%) and biological agents (up to 55% in some regions), mainly due to surface water sources. Underground water sources show relatively low levels of biological contamination, while chemical contamination is high due to additional water contamination during water treatment and transportation in pipelines. Non-centralized water sources are highly contaminated (both chemically and biologically) in 32-90% of samples analyzed. Very high levels of chemical contamination of drinking water (up to 51%) were detected in many regions, mainly in the north-western part of the Russian Arctic. Biological contamination of drinking water was generally much lower (2.5-12%) everywhere except Evenki AO (27%), and general and thermotolerant coliform bacteria predominated in drinking water samples from all regions (up to 17.5 and 12.5%, correspondingly). The presence of other agents was much lower: Coliphages--0.2-2.7%, Clostridia spores, Giardia cysts, pathogenic bacteria, Rotavirus--up to 0.8%. Of a total of 56 chemical pollutants analyzed in water samples from centralized water supply systems, 32 pollutants were found to be in excess of hygienic limits, with the predominant pollutants being Fe (up to 55%), Cl (up to 57%), Al (up to 43%) and Mn (up to 45%). In 18 selected regions of the Russian Arctic, Siberia and Far East Category I and II water reservoirs, water sources (centralized--underground, surface; non-centralized) and drinking water are highly contaminated by chemical and biological agents. Full-scale reform of the Russian water industry and water security system is urgently needed, especially in selected regions.

  8. Reducing drinking water supply chemical contamination: risks from underground storage tanks.

    PubMed

    Enander, Richard T; Hanumara, R Choudary; Kobayashi, Hisanori; Gagnon, Ronald N; Park, Eugene; Vallot, Christopher; Genovesi, Richard

    2012-12-01

    Drinking water supplies are at risk of contamination from a variety of physical, chemical, and biological sources. Ranked among these threats are hazardous material releases from leaking or improperly managed underground storage tanks located at municipal, commercial, and industrial facilities. To reduce human health and environmental risks associated with the subsurface storage of hazardous materials, government agencies have taken a variety of legislative and regulatory actions--which date back more than 25 years and include the establishment of rigorous equipment/technology/operational requirements and facility-by-facility inspection and enforcement programs. Given a history of more than 470,000 underground storage tank releases nationwide, the U.S. Environmental Protection Agency continues to report that 7,300 new leaks were found in federal fiscal year 2008, while nearly 103,000 old leaks remain to be cleaned up. In this article, we report on an alternate evidence-based intervention approach for reducing potential releases from the storage of petroleum products (gasoline, diesel, kerosene, heating/fuel oil, and waste oil) in underground tanks at commercial facilities located in Rhode Island. The objective of this study was to evaluate whether a new regulatory model can be used as a cost-effective alternative to traditional facility-by-facility inspection and enforcement programs for underground storage tanks. We conclude that the alternative model, using an emphasis on technical assistance tools, can produce measurable improvements in compliance performance, is a cost-effective adjunct to traditional facility-by-facility inspection and enforcement programs, and has the potential to allow regulatory agencies to decrease their frequency of inspections among low risk facilities without sacrificing compliance performance or increasing public health risks. © 2012 Society for Risk Analysis.

  9. COSTS AND ISSUES RELATED TO REMEDIATION OF PETROLEUM-CONTAMINATED SITES

    EPA Science Inventory

    The remediation costs required at sites contaminated with petroleum-derived compounds remains a relevant issue because of the large number of existing underground storage tanks the United States and the presence of benzene, MTBE, and TBA in some drinking water supplies. Cost inf...

  10. Summary appraisals of the Nation's ground-water resources; Caribbean region

    USGS Publications Warehouse

    Gómez-Gómez, Fernando; Heisel, James E.

    1980-01-01

    Ground-water resources will continue to be important within the region. In order to meet future needs, it is necessary that hydrologic principles be applied in managing the total water resource. Optimal use of the water resources can be accomplished through conjunctive use of surface and ground waters and through conservation practices. Optimal use may involve artificial recharge, ground-water salvage, saline-ground-water mining, use of seawater, desalination of saline ground water, waste-water reuse, and use of underground space for temporary storage of wastes, which could otherwise contaminate valuable water supplies.

  11. Potable water for a city: a historic perspective from Bruges, Belgium

    NASA Astrophysics Data System (ADS)

    Vandenbohede, A.; Vandevyvere, E.

    2014-06-01

    Contributing to the optimisation of drinking-water supplies is a key responsibility for professional hydrogeologists. Thus, it is interesting to look back and put current-day practices in the framework of historic evolution and past achievements. The water supply of Bruges (Belgium), with an innovative supply system already established by the end of the 13th century, forms an interesting case study. The supply system consisted of an underground network of pipes feeding public and private wells. A special construction, the Water House, was built to overcome a topographical height difference. Population growth and industrial expansion during the 19th century increased the water demand and new solutions were necessary. Tap water became available from 1925 onwards and, as a stopgap measure to meet demand, deep groundwater was used. This invoked a lively debate among the city council, scientists and entrepreneurs, whereby both water quality and quantity were discussed. Although based on a lack of modern understanding of the groundwater system, some arguments, both pro or contra, look very familiar to current-day hydrogeologists.

  12. Israeli Sources of Conflict and Change Affecting the Middle East

    DTIC Science & Technology

    1993-04-01

    Lake Tiberias) in the north, which acts as a natural reservoir and is fed by the River Jordan, and two aquifers , or underground supplies. (13:24) There...10) Similarly, Israeli pumps are overpumping the coastal aquifer , and water is seeping in (saline intrusion). (13:24;15:36) The mountain aquifer , which...and Israeli authorities restrict Palestinian use of water so that water can flow 24 into Israel. Israel pumps more water from the mountain aquifer

  13. GIS Analysis to Assess where Shallow Ground Water Supplies in the United States are Vulnerable to Contamination by Releases of Motor Fuel from Underground Storage Tanks

    EPA Science Inventory

    Data reported on the long form of the 1990 United State Census were used to identify the number of households in each census block group that obtained water from a private source. A data file was purchased form ESRI Business Solutions (ESRI, 2009) that contained the latitude and ...

  14. Bypassing and tightening of an underground water retention system in permeable karst: case study of the hydropower plant (HPP) Bribin, Indonesia

    NASA Astrophysics Data System (ADS)

    Kudella, Peter; Loges, Iryna; Mutschler, Thomas; Eiche, Elisabeth; Ruppert, Julia; Neumann, Thomas

    2016-09-01

    In the framework of the Integrated Water Resources Management (IWRM) joint research project in the karst area of Gunung Kidul, Province of Yogyakarta Special Region on the Java Island, Indonesia, an underground hydropower driven water extraction facility in the cave "Bribin" was developed using pump-as-turbine-driven systems for freshwater supply of the rural area. As numerous other caves in the Gunung Kidul area, Bribin is part of a ramified system of all-season water-bearing subterraneous rivers and natural caves in karstic limestone. The elliptic cross section of the cave was completely closed with a concrete barrage, thus creating a year-round underground retention volume with an operational storage level of approx. 15 m. This contribution highlights the geotechnical and geohydraulic challenges handled within the sub-project "Short-time and long-time behaviour of karst rock surrounding pressure-bearing underground water-retaining structures". One key to the feasibility of an artificial water retention scheme in a natural cave is to ensure the mechanical stability of the cave roof and sidewalls. The necessary geotechnical investigations are described. Another key to the effectiveness of such a water retention concept is the control and minimization of "lost" seepage water bypassing the barrage structure through the karst rock mass. Measures to monitor and to explain the seepage phenomena are presented as well as grouting efforts to minimize them. The limitations of improving the overall tightness will be discussed. Interpretation includes the use of analytical and numerical methods.

  15. Proximity of Private Domestic Wells to Underground Storage Tanks in Oklahoma

    EPA Science Inventory

    For protecting drinking water supplies, the locations of areas with reliance on private domestic wells (hereafter referred to as “wells”) and their relationship to contaminant sources need to be determined. A key resource in the U.S. was the 1990 Census where the sour...

  16. COSTS AND ISSUES RELATED TO REMEDIATION OF PETROLEUM-CONTAMINATED SITES (NEW ORLEANS, LA)

    EPA Science Inventory

    The remediation costs required at sites contaminated with petroleum-derived compounds remains a relevant issue because of the large number of existing underground storage tanks the United States and the presence of benzene, MTBE, and TBA in some drinking water supplies. Cost inf...

  17. Water Wells Monitoring Using SCADA System for Water Supply Network, Case Study: Water Treatment Plant Urseni, Timis County, Romania

    NASA Astrophysics Data System (ADS)

    Adrian-Lucian, Cococeanu; Ioana-Alina, Cretan; Ivona, Cojocinescu Mihaela; Teodor Eugen, Man; Narcis, Pelea George

    2017-10-01

    The water supply system in Timisoara Municipality is insured with about 25-30 % of the water demand from wells. The underground water headed to the water treatment plant in order to ensure equal distribution and pressure to consumers. The treatment plants used are Urseni and Ronaţ, near Timisoara, in Timis County. In Timisoara groundwater represents an alternative source for water supply and complementary to the surface water source. The present paper presents a case study with proposal and solutions for rehabilitation /equipment /modernization/ automation of water drilling in order to ensure that the entire system can be monitored and controlled remotely through SCADA (Supervisory control and data acquisition) system. The data collected from the field are designed for online efficiency monitoring regarding the energy consumption and water flow intake, performance indicators such as specific energy consumption KW/m3 and also in order to create a hydraulically system of the operating area to track the behavior of aquifers in time regarding the quality and quantity aspects.

  18. Rooftop level rainwater harvesting system

    NASA Astrophysics Data System (ADS)

    Traboulsi, Hayssam; Traboulsi, Marwa

    2017-05-01

    Unfortunately, in Lebanon and other countries in the Middle East region, water becomes scarcer than ever before, and over the last decades the demand on domestic water has increased due to population and economic growth. Although rainwater harvesting is considered to be a safe and reliable alternative source for domestic water, the inconvenience or impracticalities related to the cost and space needed for the construction of ground or underground storage tanks makes this practice not widely common in rural areas and rarely implemented in urban cities. This paper introduces a new technique to rainwater harvesting which can be easily used in both rural and urban areas: it collects and stores rainwater directly in tanks already installed on building roofs and not necessarily in special ground or underground ones. If widely adopted in Lebanon, this technique could help in: (1) collecting around 23 MCM (70 % of the current deficit in the domestic water supply) of rainwater and thus increasing the available water per m2 of building by 0.4 m3 per year, (2) saving around 7 % of the amount of electric energy usually needed to pump water from an aquifer well and ground or underground tank, and (3) considerably reducing the rate of surface runoff of rainwater at the coastal zones where rainwater is not captured at all and goes directly to the sea.

  19. Food and water security issues in Russia II: Water security in general population of Russian Arctic, Siberia and Far East, 2000–2011

    PubMed Central

    Dudarev, Alexey A.; Dushkina, Eugenia V.; Sladkova, Yuliya N.; Alloyarov, Pavel R.; Chupakhin, Valery S.; Dorofeyev, Vitaliy M.; Kolesnikova, Tatjana A.; Fridman, Kirill B.; Evengard, Birgitta; Nilsson, Lena M.

    2013-01-01

    Background Poor state of water supply systems, shortage of water purification facilities and disinfection systems, low quality of drinking water generally in Russia and particularly in the regions of the Russian Arctic, Siberia and Far East have been defined in the literature. However, no standard protocol of water security assessment has been used in the majority of studies. Study design and methods Uniform water security indicators collected from Russian official statistical sources for the period 2000–2011 were used for comparison for 18 selected regions in the Russian Arctic, Siberia and Far East. The following indicators of water security were analyzed: water consumption, chemical and biological contamination of water reservoirs of Categories I and II of water sources (centralized – underground and surface, and non-centralized) and of drinking water. Results Water consumption in selected regions fluctuated from 125 to 340 L/person/day. Centralized water sources (both underground and surface sources) are highly contaminated by chemicals (up to 40–80%) and biological agents (up to 55% in some regions), mainly due to surface water sources. Underground water sources show relatively low levels of biological contamination, while chemical contamination is high due to additional water contamination during water treatment and transportation in pipelines. Non-centralized water sources are highly contaminated (both chemically and biologically) in 32–90% of samples analyzed. Very high levels of chemical contamination of drinking water (up to 51%) were detected in many regions, mainly in the north-western part of the Russian Arctic. Biological contamination of drinking water was generally much lower (2.5–12%) everywhere except Evenki AO (27%), and general and thermotolerant coliform bacteria predominated in drinking water samples from all regions (up to 17.5 and 12.5%, correspondingly). The presence of other agents was much lower: Coliphages – 0.2–2.7%, Clostridia spores, Giardia cysts, pathogenic bacteria, Rotavirus – up to 0.8%. Of a total of 56 chemical pollutants analyzed in water samples from centralized water supply systems, 32 pollutants were found to be in excess of hygienic limits, with the predominant pollutants being Fe (up to 55%), Cl (up to 57%), Al (up to 43%) and Mn (up to 45%). Conclusion In 18 selected regions of the Russian Arctic, Siberia and Far East Category I and II water reservoirs, water sources (centralized – underground, surface; non-centralized) and drinking water are highly contaminated by chemical and biological agents. Full-scale reform of the Russian water industry and water security system is urgently needed, especially in selected regions. PMID:24350065

  20. Dependable water supplies from valley alluvium in arid regions.

    PubMed

    Van Haveren, Bruce P

    2004-12-01

    Reliable sources of high-quality water for domestic use are much needed in arid regions. Valley alluvium, coarse sand and gravel deposited by streams and rivers, provides an ideal storage medium for water in many regions of the world. However, river sediments will not accumulate in a valley without a natural or artificial barrier to slow the water. Sediments will deposit upstream of a barrier dam and form an alluvial deposit of relatively well-sorted material. The alluvium then acts as both an underground water-supply reservoir and a water filter, yielding a constant flow of high-quality water. Trap dams that store water in alluvial sediments and slowly release the filtered water represent an appropriate and inexpensive technology for combating desertification and mitigating the effects of drought at the community level. Small trap dams may be built as a community project using local materials and local labor.

  1. Transfer of adapted water supply technologies through a demonstration and teaching facility

    NASA Astrophysics Data System (ADS)

    Nestmann, F.; Oberle, P.; Ikhwan, M.; Stoffel, D.; Blaß, H. J.; Töws, D.; Schmidt, S.

    2016-09-01

    Water scarcity can be defined as a lack of sufficient water resources or as the limited or even missing access to a safe water supply. Latter can be classified as `economic water scarcity' which among others can commonly be met in tropical and subtropical karst regions of emerging and developing countries. Karst aquifers, mostly consisting of limestone and carbonate rock, show high infiltration rates which leads to a lack of above ground storage possibilities. Thus, the water will drain rapidly into the underground and evolve vast river networks. Considering the lack of appropriate infrastructure and limited human capacities in the affected areas, these underground water resources cannot be exploited adequately. Against this, background innovative and adapted technologies are required to utilize hard-to-access water resources in a sustainable way. In this context, the German-Indonesian joint R&D project "Integrated Water Resources Management (IWRM) Indonesia" dealt with the development of highly adaptable water technologies and management strategies. Under the aegis of the Karlsruhe Institute of Technology (KIT) and funded by the German Ministry of Education and Research (BMBF), these innovative technical concepts were exemplarily implemented to remedy this deficiency in the model region Gunung Sewu, a karst area situated on the southern coast of Java Island, Indonesia. The experiences gained through the interdisciplinary joint R&D activities clearly showed that even in the case of availability of appropriate technologies, a comprising transfer of knowhow and the buildup of capabilities (Capacity Development) is inevitable to sustainably implement and disseminate new methods. In this context, an adapted water supply facility was developed by KIT which hereafter shall serve for demonstration, teaching, and research purposes. The plant's functionality, its teaching and research concept, as well as the design process, which was accomplished in collaboration with the University Gadjah Mada (UGM), Yogyakarta, Indonesia, is the content of this present paper.

  2. Review of water demand and water utilization studies for the Provo River drainage basin, and review of a study of the effects of the proposed Jordanelle Reservoir on seepage to underground mines, Bonneville unit of the central Utah project

    USGS Publications Warehouse

    Waddell, K.M.; Freethey, G.W.; Susong, D.D.; Pyper, G.E.

    1991-01-01

    Problem: Questions have been raised concerning the adequacy of available water to fulfill the needs of storage, exchanges, diversions, and instream flows, pursuant to existing water rights in the Provo River drainage basin part of the Bonneville Unit. Also, concern has been expressed about the potential for seepage of water from Jordanelle Reservoir to underground mines. The Utah Congressional Delegation requested that the U.S. Geological Survey (USGS) review the results of analyses performed by and for the USBR.Purpose and Scope: The purpose of this report is to present the results of the USGS review of (1) the hydrologic data, techniques, and model used by the USBR in their hydrologic analyses of the Provo River drainage basin and (2) the results of a study of the potential for seepage from the Jordanelle Reservoir to nearby underground mines.The USGS reviewed USBR-supplied water demands, water utilization studies, and models of seepage from Jordanelle Reservoir. The USBR estimated that about 90 percent of the water supply for Jordanelle Reservoir will be water from Strawberry Reservoir exchanged for water from the Provo River stored in Utah Lake. If the Utah State Engineer allows the USBR to claim an estimated 19,700 acre-feet of return flows from the CUP, only about 77 percent of the supply would be derived from exchange of existing water rights in Utah Lake. The USGS assumed that planned importations of water from the Uinta Basin will be available and deliverable to fulfill the proposed exchanges.Water rights and demands are important for determining water availability. The USGS did not conduct an independent review of water rights and demands. The USSR and Utah Division of Water Rights use different methods in some areas for determining stress on the system based on past records. The USSR used "historical observed diversions" and the Utah Division of Water Rights use "diversion entitlements", which may not be equal to the historical diversions. The USGS based its review upon water demands used by the USSR. The Utah Division of Water Rights has responsibility for granting and enforcing water rights, and the final decisions on how the rights will be adjudicated lies with the Utah Division of Water Rights and with the courts. The USGS review did not consider the draft water distribution plan for the Utah Lake drainage basin proposed by the Utah State Engineer (written commun., October 15,1991). This plan, when finalized, may have an effect on water availability to the CUP.

  3. 75 FR 32171 - American Electric Power Service Corporation's Mountaineer Commercial Scale Carbon Capture and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-07

    ...) appropriated $3.4 billion to DOE for Fossil Energy Research and Development; the Department intends to use a... concentrated, high-pressure form suitable for sequestration. The concentrated CO 2 stream would be cooled and... underground resources such as ground water supplies, mineral resources, and fossil fuel resources; Fate and...

  4. Glacier meltwater flow paths and storage in a geomorphologically complex glacial foreland: The case of the Tapado glacier, dry Andes of Chile (30°S)

    NASA Astrophysics Data System (ADS)

    Pourrier, J.; Jourde, H.; Kinnard, C.; Gascoin, S.; Monnier, S.

    2014-11-01

    The Tapado catchment is located in the upper Elqui river basin (4000-5550 m) in northern Chile. It comprises the Tapado glacial complex, which is an assemblage of the Tapado glacier and the glacial foreland (debris-covered glacier, rock glacier, and moraines). Although the hydrological functioning of this catchment is poorly known, it is assumed to actively supply water to the lower semi-arid areas of the Elqui river basin. To improve our knowledge of the interactions and water transfers between the cryospheric compartment (glacier, debris-covered glacier, and rock glacier) and the hydrological compartment (aquifers, streams), the results of monitoring of meteorological conditions, as well as discharge, conductivity and temperature of streams and springs located in the Tapado catchment were analyzed. The hydrological results are compared to results inferred from a ground penetrating radar (GPR) survey of the underground structure of the glacial foreland. Water production from the Tapado glacier was shown to be highly correlated with daily and monthly weather conditions, particularly solar radiation and temperature. The resulting daily and monthly streamflow cycles were buffered by the glacial foreland, where underground transfers took place through complex flow paths. However, the development of a thermokarst drainage network in a portion of the glacial foreland enabled rapid concentrated water transfers that reduced the buffer effect. The glacial foreland was shown to act as a reservoir, storing water during high melt periods and supplying water to downstream compartments during low melt periods. GPR observations revealed the heterogeneity of the internal structure of the glacial foreland, which is composed of a mixture of ice and rock debris mixture, with variable spatial ice content, including massive ice lenses. This heterogeneity may explain the abovementioned hydrological behaviors. Finally, calculation of a partial hydrological budget confirmed the importance of the Tapado catchment in supplying water to lower areas of the Elqui river basin. Water production from, and transfer through, cryospheric compartments, and its subsequent interactions with hydrological compartments are key processes driving the summer water supply from the Tapado catchment.

  5. Efficiency evaluation of agricultural underground dam in South Korea

    NASA Astrophysics Data System (ADS)

    Myoung, W.; Song, S. H.; Yong, H. H.

    2017-12-01

    Climate change has resulted in severe droughts in a rice-planting season (i.e., April to June) in South Korea since 2012. Therefore, all time high-amount water resources in rice-farming seasons (i.e., April to October) were required against natural crises like droughts. The underground dam, which is able to increase groundwater amounts in the alluvium aquifer, has been considered to be an alternative for securing more groundwater resources. In this study, irrigation efficiencies of five pre-existing agricultural underground dams in South Korea were evaluated during the drought periods. A total amount of groundwater storage capacities in alluvial aquifers of these five ones were estimated approximate 15 × 107 m3: above 4 × 106 m3 for two underground dams (Ian, Namsong), 2 3 × 106 m3, for 2 dams (Oksung, Wooil), below 2 × 106 m3 for 1 dam (Gocheon), respectively. Irrigating amounts of groundwater accounted for three underground dams (Ian, Namsong, Gocheon), supplied in rice-farming season are 8.5 × 105 m3/year, 8.3 × 105 m3/year, 6.3 × 105 m3/year, respectively. The total demand of agricultural water in these underground dams is 2.0 × 106 m3/year, 1.9 × 106 m3/year, 2.2 × 106 m3/year, respectively. Irrigating amounts of groundwater accounted for whole of rice-farming area in South Korea is 4.3 × 108 m3/year whereas total demand of agricultural water is 9.4 × 109 m3/year. Groundwater were pumped from the radial collector wells located in the upstream from the underground dams. Oksung underground dam, one representative underground dam located in Chungnam province in South Korea, irrigated approximate 3 × 105 m3 during a dried rice-planting season (between April to June) in 2017. It was three times more than usual (9 × 104 m3). Groundwater levels during the same period maintained above 5.55 m, which was slightly lower than usual (6.00 m). Results of Oksung underground dam demonstrated that underground dams in South Korea were effectively operated against drought. Recently, Korea Rural Community Corporation, a governmental institute of South Korea, plans to construct more underground dams against drought.

  6. Ground water in Utah - A summary description of the resource and its related physical environment

    USGS Publications Warehouse

    Price, Don; Arnow, Ted

    1985-01-01

    Ground water is one of Utah’s most extensive and valuable natural resources. Because of its widespread occurrence in both wet and dry areas, ground water has been, and is a major factor affecting economic growth and development of the State. In some areas, ground water is used to supplement streamflow for irrigation, public supply, and other uses. In other areas, it is the only water available for use. Many communities obtain their entire water supply from ground-water sources (wells and springs) as do numerous rural and suburban households throughout the State.The ground-water reservoirs of Utah contain tremendous quantities of water – many times more than the quantity stored in all the lakes (including Great Salt Lake) and the surface-water reservoirs of the State combined. Water that discharges from those underground reservoirs in seeps and springs is vital in sustaining the flow of streams during dry summer months and in providing the water needed to maintain important wetland habitats. Those same underground reservoirs also provide large quantities of water in carryover storage for use during prolonged droughts.The U.S. Geological survey, under cooperative programs with the Utah department of Natural resources and other Federal, State, and local agencies has been studying Utah’s ground-water resources since 1897. Much information has been gained during those studies about the occurrence, availability, and quality of ground water; the withdrawal and use of the water; and the effects of withdrawal. This report summarizes that information in nontechnical language, which is designed for all readers. Readers interested in more detailed information about ground water in specific areas of Utah are referred to the reports listed by LaPray and Hamblin (1980).

  7. Underground waters of eastern United States

    USGS Publications Warehouse

    Fuller, Myron L.

    1905-01-01

    The present paper is a brief summary of the underground water conditions in eastern United States, prepared to meet the demands of drillers and others for information relating to the general water resources of the various States or of specified regions.The detail with which the several regions or subjects are discussed depends mainly on their relative importance, although because of the greater amount of work done in certain localities, or on certain problems, it is possible to make more complete and definite statements in regard to the underground water supplies in some regions than in others. The included reports have been prepared by a number of geologists, each, in general, having charge of the investigations in a particular State or group of States. Because of the number of contributors there is necessarily considerable variation in the manner of treatment of the subject, but in most cases the same general plan has been followed.In preparing the paper simplicity of treatment has been kept in mind, and elaborate geologic discussions have been omitted. Wherever possible maps have been given in preference to long and possibly obscure discussions. In some instances, however, it has been necessary to describe the various water-bearing formations under their geologic names. Where this has been necessary the aim has been to employ those terms which are oldest and best known to the people of the States to which the discussion relates.For the purpose of presenting in a simple manner a few of the more important features relating to the nature and occurrence of subterranean waters and of making more intelligible the descriptions of the conditions in the various States, there is given a short paper on the general occurrence of underground waters.

  8. [The global and national context regarding the challenges involved in ensuring adequate access to water for human consumption].

    PubMed

    Augusto, Lia Giraldo da Silva; Gurgel, Idê Gomes Dantas; Câmara Neto, Henrique Fernandes; de Melo, Carlos Henrique; Costa, André Monteiro

    2012-06-01

    The scope of this article is to analyze the challenges involved in ensuring access to water for human consumption taking the international and national context into consideration. Based on the UN declaration that access to safe and clean drinking water is a fundamental human right, vulnerabilities are identified that can consist in restrictions to access to adequate supplies. The distribution of water and the population across the planet, pollution, inadequate policies and management lead to environmental injustice. The iniquity of access to water constitutes the contemporary water crisis. From the 1980s onwards, the transnational water market emerged for private control that occurs at three main levels: surface and underground water sources; bottled water; and public water supply services. The conflicts of the multiple uses of water resources, the market and environmental problems have contributed to rendering the health of the population and ecosystems vulnerable. Adequate public policies are essential to ensure the basic human right to access to safe and clean drinking water.

  9. 30 CFR 75.811 - High-voltage underground equipment; grounding.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...-voltage equipment supplying power to such equipment receiving power from resistance grounded systems shall... 30 Mineral Resources 1 2010-07-01 2010-07-01 false High-voltage underground equipment; grounding... COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Underground High-Voltage...

  10. Effect of point-of-use, activated carbon filters on the bacteriological quality of rural groundwater supplies.

    PubMed Central

    Synder, J W; Mains, C N; Anderson, R E; Bissonnette, G K

    1995-01-01

    The water quality of 24 rural, domestic groundwater supplies treated with point-of-use, powdered activated carbon (PAC) filters was monitored to determine how such treatment might impact the bacteriological quality of private, residential drinking water supplies. Heterotrophic-plate-count (HPC) and total coliform analyses were performed on raw, PAC-treated, and overnight or stagnant (first-draw) PAC-treated water samples. Densities of HPC bacteria were elevated by 0.86 and 0.20 orders of magnitude for spring and well water systems, respectively, in PAC-treated effluents following overnight stagnation compared with levels in untreated treated effluents. Densities of HPC bacteria in PAC-treated effluents were significantly reduced (P < 0.01) below influent levels, however, after the point-of-use device was flushed for 2 min. While PAC significantly reduced the number of coliforms in product waters (P < 0.01), these indicator organisms were still detected in some effluents. Seasonal variations were evident in microbial counts from spring but not well water systems. It appears that aside from periods following stagnant-water use, such as overnight, PAC treatment does not compromise the bacteriological quality of drinking water obtained from underground sources. PMID:8534096

  11. Present and Future Water Supply for Mammoth Cave National Park, Kentucky

    USGS Publications Warehouse

    Cushman, R.V.; Krieger, R.A.; McCabe, John A.

    1965-01-01

    The increase in the number of visitors during the past several years at Mammoth Cave National Park has rendered the present water supply inadequate. Emergency measures were necessary during August 1962 to supplement the available supply. The Green River is the largest potential source of water supply for Mammoth Cave. The 30-year minimum daily discharge is 40 mgd (million gallons per day) . The chemical quality is now good, but in the past the river has been contaminated by oil-field-brine wastes. By mixing it with water from the existing supply, Green River water could be diluted to provide water of satisfactory quality in the event of future brine pollution. The Nolin River is the next largest potential source of water (minimum releases from Nolin Reservoir, 97-129 mgd). The quality is satisfactory, but use of this source would require a 8-mile pipeline. The present water supply comes from springs draining a perched aquifer in the Haney Limestone Member of the Golconda Formation on Flint Ridge. Chemical quality is excellent but the minimum observed flow of all the springs on Flint Ridge plus Bransford well was only 121,700 gpd (gallons per day). This supply is adequate for present needs but not for future requirements; it could be augmented with water from the Green River. Wet Prong Buffalo Creek is the best of several small-stream supplies in the vicinity of Mammoth Cave. Minimum flow of the creek is probably about 300,000 gpd and the quality is good. The supply is about 5 miles from Mammoth Cave. This supply also may be utilized for a future separate development in the northern part of the park. The maximum recorded yield of wells drilled into the basal ground water in the Ste. Genevieve and St. Louis Limestone is 36 gpm (gallons per minute). Larger supplies may be developed if a large underground stream is struck. Quality can be expected to be good unless the well is drilled too far below the basal water table and intercepts poorer quality water at a lower level. This source of supply might be used to augment the present supply, but locating the trunk conduits might be difficult. Water in alluvium adjacent to the Green River and perched water in the Big Clifty Sandstone Member of the Golconda Formation and Girkin Formation have little potential as a water supply.

  12. Prediction in Ungauged Basins (PUB) for estimating water availability during water scarcity conditions: rainfall-runoff modelling of the ungauged diversion inflows to the Ridracoli water supply reservoir

    NASA Astrophysics Data System (ADS)

    Toth, Elena

    2013-04-01

    The Ridracoli reservoir is the main drinking water supply reservoir serving the whole Romagna region, in Northern Italy. Such water supply system has a crucial role in an area where the different characteristics of the communities to be served, their size, the mass tourism and the presence of food industries highlight strong differences in drinking water needs. Its operation allows high quality drinking water supply to a million resident customers, plus a few millions of tourists during the summer of people and it reduces the need for water pumping from underground sources, and this is particularly important since the coastal area is subject also to subsidence and saline ingression into aquifers. The system experienced water shortage conditions thrice in the last decade, in 2002, in 2007 and in autumn-winter 2011-2012, when the reservoir water storage fell below the attention and the pre-emergency thresholds, thus prompting the implementation of a set of mitigation measures, including limitations to the population's water consumption. The reservoir receives water not only from the headwater catchment, closed at the dam, but also from four diversion watersheds, linked to the reservoir through an underground water channel. Such withdrawals are currently undersized, abstracting only a part of the streamflow exceeding the established minimum flows, due to the design of the water intake structures; it is therefore crucial understanding how the reservoir water availability might be increased through a fuller exploitation of the existing diversion catchment area. Since one of the four diversion catchment is currently ungauged (at least at the fine temporal scale needed for keeping into account the minimum flow requirements downstream of the intakes), the study first presents the set up and parameterisation of a continuous rainfall-runoff model at hourly time-step for the three gauged diversion watersheds and for the headwater catchment: a regional parameterisation approach is then applied for modelling the streamflow originated in the fourth, ungauged, diversion watershed. Finally, the potential reservoir water availability is estimated, hypothesising to take from the diversion catchments all the streamflow exceeding the minimum flow requirements. The results indicate that modifying the water intake structures might allow a consistent increase in the storage volumes in the reservoir during the water scarcity periods: the water available to the reservoir would in fact - on average - increase of around the 13% of the abstracted annual volume.

  13. Selected water-quality data for the Standard Mine, Gunnison County, Colorado, 2006-2007

    USGS Publications Warehouse

    Verplanck, Philip L.; Manning, Andrew H.; Mast, M. Alisa; Wanty, Richard B.; McCleskey, R. Blaine; Todorov, Todor I.; Adams, Monique

    2007-01-01

    Mine drainage and underground water samples were collected for analysis of inorganic solutes as part of a 1-year, hydrogeologic investigation of the Standard Mine and vicinity. The U.S. Environmental Protection Agency has listed the Standard Mine in the Elk Creek drainage near Crested Butte, Colorado, as a Superfund Site because discharge from the Standard Mine enters Elk Creek, contributing dissolved and suspended loads of zinc, cadmium, copper, and other metals to Coal Creek, which is the primary drinking-water supply for the town of Crested Butte. Water analyses are reported for mine-effluent samples from Levels 1 and 5 of the Standard Mine, underground samples from Levels 3 and 5 of the Standard Mine, mine effluent from an adit located on the Elk Lode, and two spring samples that emerged from waste-rock material below Level 5 of the Standard Mine and the adit located on the Elk Lode. Reported analyses include field parameters (pH, specific conductance, water temperature, dissolved oxygen, and redox potential) and major constituents and trace elements.

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alder, J.; Cook, W.J.; McGuire, S.

    The overuse of ancient underground aquifers combines with an uneven distribution of water resource, drought, waste, and pollution to present serious policy choices which could follow the same ineffective path as our oil policies. Irrigating arid and semi-arid lands is an energy-intensive and expensive undertaking that needs to be reexamined. Water shortages due to shifts in weather patterns can lead to heavier-than-normal reliance on the major aquifers, while contamination of surface and ground waters further depletes US water supplies. Policy decisions must be made that will alter wasteful consumption habits, introducing metering and conservation to convince Americans that cheap water,more » like cheap oil, is no longer available. (DCK)« less

  15. Geostatistical Characteristic of Space -Time Variation in Underground Water Selected Quality Parameters in Klodzko Water Intake Area (SW Part of Poland)

    NASA Astrophysics Data System (ADS)

    Namysłowska-Wilczyńska, Barbara

    2016-04-01

    This paper presents selected results of research connected with the development of a (3D) geostatistical hydrogeochemical model of the Klodzko Drainage Basin, dedicated to the spatial and time variation in the selected quality parameters of underground water in the Klodzko water intake area (SW part of Poland). The research covers the period 2011÷2012. Spatial analyses of the variation in various quality parameters, i.e, contents of: ammonium ion [gNH4+/m3], NO3- (nitrate ion) [gNO3/m3], PO4-3 (phosphate ion) [gPO4-3/m3], total organic carbon C (TOC) [gC/m3], pH redox potential and temperature C [degrees], were carried out on the basis of the chemical determinations of the quality parameters of underground water samples taken from the wells in the water intake area. Spatial and time variation in the quality parameters was analyzed on the basis of archival data (period 1977÷1999) for 22 (pump and siphon) wells with a depth ranging from 9.5 to 38.0 m b.g.l., later data obtained (November 2011) from tests of water taken from 14 existing wells. The wells were built in the years 1954÷1998. The water abstraction depth (difference between the terrain elevation and the dynamic water table level) is ranged from 276÷286 m a.s.l., with an average of 282.05 m a.s.l. Dynamic water table level is contained between 6.22 m÷16.44 m b.g.l., with a mean value of 9.64 m b.g.l. The latest data (January 2012) acquired from 3 new piezometers, with a depth of 9÷10m, which were made in other locations in the relevant area. Thematic databases, containing original data on coordinates X, Y (latitude, longitude) and Z (terrain elevation and time - years) and on regionalized variables, i.e. the underground water quality parameters in the Klodzko water intake area determined for different analytical configurations (22 wells, 14 wells, 14 wells + 3 piezometers), were created. Both archival data (acquired in the years 1977÷1999) and the latest data (collected in 2011÷2012) were analyzed. These data were subjected to spatial analyses using statistical and geostatistical methods. The evaluation of basic statistics of the investigated quality parameters, including their histograms of distributions, scatter diagrams between these parameters and also correlation coefficients r were presented in this article. The directional semivariogram function and the ordinary (block) kriging procedure were used to build the 3D geostatistical model. The geostatistical parameters of the theoretical models of directional semivariograms of the studied water quality parameters, calculated along the time interval and along the wells depth (taking into account the terrain elevation), were used in the ordinary (block) kriging estimation. The obtained results of estimation, i.e. block diagrams allowed to determine the levels of increased values Z* of studied underground water quality parameters. Analysis of the variability in the selected quality parameters of underground water for an analyzed area in Klodzko water intake was enriched by referring to the results of geostatistical studies carried out for underground water quality parameters and also for a treated water and in Klodzko water supply system (iron Fe, manganese Mn, ammonium ion NH4+ contents), discussed in earlier works. Spatial and time variation in the latter-mentioned parameters was analysed on the basis of the data (2007÷2011, 2008÷2011). Generally, the behaviour of the underground water quality parameters has been found to vary in space and time. Thanks to the spatial analyses of the variation in the quality parameters in the Kłodzko underground water intake area some regularities (trends) in the variation in water quality have been identified.

  16. Characterizing ecosystem response to water supply changes inferred from GRACE drought severity index and surface soil moisture anomalies from ESA CCI and SMAP

    NASA Astrophysics Data System (ADS)

    Zhao, M.; Velicogna, I.; Kimball, J. S.

    2017-12-01

    Climate change such as more frequent heatwaves and drought is threatening our food security and ecosystem by reducing water supply to vegetation. Characterizing vegetation response to water supply changes is not only important for evaluating and mitigating climatic change impacts on ecosystem functions and services, but also to determine the feedback mechanisms that ecosystem response may generate on the climate itself. However, such characterization is not well-known at the global scale partly because large scale observations of underground water supply changes are limited. Satellite observations of soil moisture (SM) datasets such as from Soil Moisture Active and Passive (SMAP) and European Space Agency Climate Change Initiative (ESA CCI) do not penetrate more than a few centimeters and do not capture the entire root-zone. Here we employ a newly developed Drought Severity Index from Gravity Recovery and Climate Experiment (GRACE-DSI) to complement SM observations by informing total water supply changes in the entire terrestrial hydrological cycle. We use MODIS vegetation indices as proxies for vegetation growth and investigate their seasonal and interannual variability in relation to GRACE-DSI. We find that total water supply constrains vegetation growth across the entire continental US. Water constraint begins at an earlier date of year and lasts for a longer period in the lower latitude than in the higher latitude. We also find that water constraint occurs at different phenological stages depending on vegetation type. For instance, water constrain forest growth during reproductive period in eastern US but constrain shrub land growth during green-up in Arizona (Fig. 1). In western United States, eastern Australia and the horn of Africa, we find that vegetation growth changes closely follows GRACE-DSI but can have 16-day to one-month delay with respect to SM anomalies from SMAP and ESA CCI. This suggests that in these regions, vegetation is sensitive to water supply changes in the deeper soil layers than in the shallower surface.

  17. Technology Transfer Opportunities: Automated Ground-Water Monitoring, A Proven Technology

    USGS Publications Warehouse

    Smith, Kirk P.; Granato, Gregory E.

    1998-01-01

    Introduction The U.S. Geological Survey (USGS) has developed and tested an automated ground-water monitoring system that measures and records values of selected water-quality properties and constituents using protocols approved for manual sampling. Prototypes using the automated process have demonstrated the ability to increase the quantity and quality of data collected and have shown the potential for reducing labor and material costs for ground-water quality data collection. Automated ground-water monitoring systems can be used to monitor known or potential contaminant sites, such as near landfills, underground storage tanks, or other facilities where potential contaminants are stored, to serve as early warning systems monitoring ground-water quality near public water-supply wells, and for ground-water quality research.

  18. Long Term Hydrological (Radiological) Site Monitoring Data

    EPA Pesticide Factsheets

    Quality Data Asset includes all current and historical data on the quality of water with regard to the presence of water pollutants of all kinds regulated by the Clean Water Act. Under the new Interagency Agreement with the Department of Energy (DOE), the Radiation & Indoor Environments National Laboratory (R&IE), Office of Radiation and Indoor Air (ORIA), EPA, located in Las Vegas, NV, conducts a Long-Term Hydrological Monitoring Program (LTHMP) providing laboratory sampling/analysis and Quality Assurance and Control to measure radioactivity concentrations in the water sources near the sites of former underground nuclear explosions. The results of the LTHMP provide assurance that radioactive material from the tests have not migrated into water supplies.

  19. Influence of a source line position on results of EM observations applied to the diagnostics of underground heating system pipelines in urban area

    NASA Astrophysics Data System (ADS)

    Vetrov, A.

    2009-05-01

    The condition of underground constructions, communication and supply systems in the cities has to be periodically monitored and controlled in order to prevent their breakage, which can result in serious accident, especially in urban area. The most risk of damage have the underground construction made of steal such as pipelines widely used for water, gas and heat supply. To ensure the pipeline survivability it is necessary to carry out the operative and inexpensive control of pipelines condition. Induced electromagnetic methods of geophysics can be applied to provide such diagnostics. The highly developed surface in urbane area is one of cause hampering the realization of electromagnetic methods of diagnostics. The main problem is in finding of an appropriate place for the source line and electrodes on a limited surface area and their optimal position relative to the observation path to minimize their influence on observed data. Author made a number of experiments of an underground heating system pipeline diagnostics using different position of the source line and electrodes. The experiments were made on a 200 meters section over 2 meters deep pipeline. The admissible length of the source line and angle between the source line and the observation path were determined. The minimal length of the source line for the experiment conditions and accuracy made 30 meters, the maximum admissible angle departure from the perpendicular position made 30 degrees. The work was undertaken in cooperation with diagnostics company DIsSO, Saint-Petersburg, Russia.

  20. 30 CFR 75.802 - Protection of high-voltage circuits extending underground.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Protection of high-voltage circuits extending...-Voltage Distribution § 75.802 Protection of high-voltage circuits extending underground. (a) Except as provided in paragraph (b) of this section, high-voltage circuits extending underground and supplying...

  1. 30 CFR 75.802 - Protection of high-voltage circuits extending underground.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Protection of high-voltage circuits extending...-Voltage Distribution § 75.802 Protection of high-voltage circuits extending underground. (a) Except as provided in paragraph (b) of this section, high-voltage circuits extending underground and supplying...

  2. 30 CFR 75.802 - Protection of high-voltage circuits extending underground.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Protection of high-voltage circuits extending...-Voltage Distribution § 75.802 Protection of high-voltage circuits extending underground. (a) Except as provided in paragraph (b) of this section, high-voltage circuits extending underground and supplying...

  3. Guide to North Dakota's ground-water resources

    USGS Publications Warehouse

    Paulson, Q.F.

    1983-01-01

    Ground water, the water we pump from the Earth through wells or that which flows naturally from springs, is one of North Dakota's most valuable resources. More than 60 percent of the people living in the State use ground water for one purpose of another. It is the only source of water for thousands of farm families and their livestock. Almost all smaller cities and villages depend solely on groudn water as a source of supply. Increasingly, ground water is being used to irrigate crops and grasslands (fig. 1) during protracted dry spells so common in North Dakota. During recent years there has been a rapid development of rural water ditribution systems in which thousands of farms and rurals residences are connected via underground pipeline to a single water source, usually wells pumping ground water.

  4. Current (2004-07) Conditions and Changes in Ground-Water Levels from Predevelopment to 2007, Southern High Plains Aquifer, East-Central New Mexico-Curry County, Portales, and Causey Lingo Underground Water Basins

    USGS Publications Warehouse

    Tillery, Anne

    2008-01-01

    The Southern High Plains aquifer is the principal aquifer in Curry and Roosevelt Counties, N. Mex., and primary source of water in southeastern New Mexico. Successful water-supply planning for New Mexico's Southern High Plains requires knowledge of the current aquifer conditions and a context to estimate future trends given current aquifer-management policy. This report provides a summary of the current (2007) water-level status of the Southern High Plains aquifer in New Mexico, including a basis for estimating future trends by comparison with historical conditions. This report includes estimates of the extent of ground-water level declines in the Curry County, Portales, and Causey-Lingo Ground-water Management Area parts of the High Plains Aquifer in eastern New Mexico since predevelopment. Maps representing 2007 water levels, water-level declines, aquifer saturated thickness, and depth to water accompanied by hydrographs from representative wells for the Southern High Plains aquifer in the Curry County, Portales, and Causey Lingo Underground Water Basins were prepared in cooperation with the New Mexico Office of the State Engineer. The results of this mapping show the water level declined as much as 175 feet in the study area at rates as high as 1.76 feet per year.

  5. Drinking water quality assessment in Southern Sindh (Pakistan).

    PubMed

    Memon, Mehrunisa; Soomro, Mohammed Saleh; Akhtar, Mohammad Saleem; Memon, Kazi Suleman

    2011-06-01

    The southern Sindh province of Pakistan adjoins the Arabian Sea coast where drinking water quality is deteriorating due to dumping of industrial and urban waste and use of agrochemicals and yet has limited fresh water resources. The study assessed the drinking water quality of canal, shallow pumps, dug wells, and water supply schemes from the administrative districts of Thatta, Badin, and Thar by measuring physical, chemical, and biological (total coliform) quality parameters. All four water bodies (dug wells, shallow pumps canal water, and water supply schemes) exceeded WHO MPL for turbidity (24%, 28%, 96%, 69%), coliform (96%, 77%, 92%, 81%), and electrical conductivity (100%, 99%, 44%, 63%), respectively. However, the turbidity was lower in underground water, i.e., 24% and 28% in dug wells and shallow pumps as compared to open water, i.e., 96% and 69% in canal and water supply schemes, respectively. In dug wells and shallow pumps, limits for TDS, alkalinity, hardness, and sodium exceeded, respectively, by 63% and 33%; 59% and 70%, 40% and 27%, and 78% and 26%. Sodium was major problem in dug wells and shallow pumps of district Thar and considerable percent in shallow pumps of Badin. Iron was major problem in all water bodies of district Badin ranging from 50% to 69% and to some extent in open waters of Thatta. Other parameters as pH, copper, manganese, zinc, and phosphorus were within standard permissible limits of World Health Organization. Some common diseases found in the study area were gastroenteritis, diarrhea and vomiting, kidney, and skin problems.

  6. Earth Tide Analysis Specifics in Case of Unstable Aquifer Regime

    NASA Astrophysics Data System (ADS)

    Vinogradov, Evgeny; Gorbunova, Ella; Besedina, Alina; Kabychenko, Nikolay

    2017-06-01

    We consider the main factors that affect underground water flow including aquifer supply, collector state, and distant earthquakes seismic waves' passage. In geodynamically stable conditions underground inflow change can significantly distort hydrogeological response to Earth tides, which leads to the incorrect estimation of phase shift between tidal harmonics of ground displacement and water level variations in a wellbore. Besides an original approach to phase shift estimation that allows us to get one value per day for the semidiurnal M2 wave, we offer the empirical method of excluding periods of time that are strongly affected by high inflow. In spite of rather strong ground motion during earthquake waves' passage, we did not observe corresponding phase shift change against the background on significant recurrent variations due to fluctuating inflow influence. Though inflow variations do not look like the only important parameter that must be taken into consideration while performing phase shift analysis, permeability estimation is not adequate without correction based on background alternations of aquifer parameters due to natural and anthropogenic reasons.

  7. Earth Tide Analysis Specifics in Case of Unstable Aquifer Regime

    NASA Astrophysics Data System (ADS)

    Vinogradov, Evgeny; Gorbunova, Ella; Besedina, Alina; Kabychenko, Nikolay

    2018-05-01

    We consider the main factors that affect underground water flow including aquifer supply, collector state, and distant earthquakes seismic waves' passage. In geodynamically stable conditions underground inflow change can significantly distort hydrogeological response to Earth tides, which leads to the incorrect estimation of phase shift between tidal harmonics of ground displacement and water level variations in a wellbore. Besides an original approach to phase shift estimation that allows us to get one value per day for the semidiurnal M2 wave, we offer the empirical method of excluding periods of time that are strongly affected by high inflow. In spite of rather strong ground motion during earthquake waves' passage, we did not observe corresponding phase shift change against the background on significant recurrent variations due to fluctuating inflow influence. Though inflow variations do not look like the only important parameter that must be taken into consideration while performing phase shift analysis, permeability estimation is not adequate without correction based on background alternations of aquifer parameters due to natural and anthropogenic reasons.

  8. Flowing wells and municipal water supplies in the southern portion of the southern peninsula of Michigan

    USGS Publications Warehouse

    Leverett, Frank

    1906-01-01

    A large amount of data on water supplies was collected by the writer in the course of glacial investigations made under the direction of Prof. T. C. Chamberlin in the last five years in the Southern Peninsula of Michigan. These investigations resulted in a partial acquaintance with conditions in about 200 separate flowing-well districts and brought out matters of such exceptional importance that arrangements were made to extend them by examining each of the flowing-well districts in the State sufficiently to determine its essential characteristics, present state of development, and probable capacity for future development. It was arranged also that the quality of various classes of waters, both surface and underground, as well as water supplies of the cities and villages, should be given attention. As the mineral waters of the State had already been discussed in some detail by the State geologist, Dr. A. C. Lane, in Water-Supply Paper No. 31 of the United States Geological Survey, it was deemed unnecessary to prepare another report on that subject, but arrangements were made with Doctor Lane for embodying in this report the large amount of material which had accumulated at his office relative to other classes of water supply, and also for furnishing reports on certain counties in which special investigations had been carried on by the State survey. The results of all these studies, so far as they apply to the southern counties (see fig. 1), are embodied in the present report; the remainder will appear in a companion report on the middle and northern counties of the Southern Peninsula of Michigan.

  9. Flowing wells and municipal water supplies in the middle and northern portions of the southern peninsula of Michigan

    USGS Publications Warehouse

    Leverett, Frank

    1907-01-01

    A large amount of data on water supplies was collected by the writer in the course of glacial investigations made under the direction of Prof. T. C. Chamberlin in the last five years in the Southern Peninsula of Michigan. These investigations resulted in a partial acquaintance with conditions in about 200 separate flowing-well districts and brought out matters of such exceptional importance that arrangements were made to extend them by examining each of the flowing-well districts in the State sufficiently to determine its essential characteristics, present state of development, and probable capacity for future development. It was arranged also that the quality of various classes of water, both surface and underground, as well as water supplies of, cities and villages, should be given attention. As the mineral waters of the State had already been discussed in some detail by the State geologist, Dr. A. C. Lane, in Water-Supply Paper No. 31 of the United States Geological Survey, it was deemed unnecessary to prepare another report on that subject, but arrangements were made with Doctor Lane for embodying in this report the large amount of material which had accumulated at his office relative to other classes of water supply, and also for furnishing reports on certain counties in which special investigations had been carried on by the State survey. The results of all these studies, so far as they apply to the middle- and northern counties (see fig. 1, on next page), are embodied in the present report; the remainder appears in a companion report on the southern counties of the Southern Peninsula of Michigan.

  10. Volatile organic compounds in the nation's ground water and drinking-water supply wells

    USGS Publications Warehouse

    Zogorski, John S.; Carter, Janet M.; Ivahnenko, Tamara; Lapham, Wayne W.; Moran, Michael J.; Rowe, Barbara L.; Squillace, Paul J.; Toccalino, Patricia L.

    2006-01-01

    This national assessment of 55 volatile organic compounds (VOCs) in ground water gives emphasis to the occurrence of VOCs in aquifers that are used as an important supply of drinking water. In contrast to the monitoring of VOC contamination of ground water at point-source release sites, such as landfills and leaking underground storage tanks (LUSTs), our investigations of aquifers are designed as large-scale resource assessments that provide a general characterization of water-quality conditions. Nearly all of the aquifers included in this assessment have been identified as regionally extensive aquifers or aquifer systems. The assessment of ground water (Chapter 3) included analyses of about 3,500 water samples collected during 1985-2001 from various types of wells, representing almost 100 different aquifer studies. This is the first national assessment of the occurrence of a large number of VOCs with different uses, and the assessment addresses key questions about VOCs in aquifers. The assessment also provides a foundation for subsequent decadal assessments of the U.S. Geological Survey (USGS) National Water-Quality Assessment (NAWQA) Program to ascertain long-term trends of VOC occurrence in these aquifers.

  11. Design of a surface-based factory for the production of life support and technology support products. Phase 2: Integrated water system for a space colony

    NASA Technical Reports Server (NTRS)

    1989-01-01

    Phase 2 of a conceptual design of an integrated water treatment system to support a space colony is presented. This includes a breathable air manufacturing system, a means of drilling for underground water, and storage of water for future use. The system is to supply quality water for biological consumption, farming, residential and industrial use and the water source is assumed to be artesian or subsurface and on Mars. Design criteria and major assumptions are itemized. A general block diagram of the expected treatment system is provided. The design capacity of the system is discussed, including a summary of potential users and the level of treatment required; and, finally, various treatment technologies are described.

  12. Groundwater quality at the Saline Valley Conservancy District well field, Gallatin County, Illinois

    USGS Publications Warehouse

    Gorczynska, Magdalena; Kay, Robert T.

    2016-08-29

    The Saline Valley Conservancy District (SVCD) operates wells that supply water to most of the water users in Saline and Gallatin Counties, Illinois. The SVCD wells draw water from a shallow sand and gravel aquifer located in close proximity to an abandoned underground coal mine, several abandoned oil wells, and at least one operational oil well. The aquifer that yields water to the SVCD wells overlies the New Albany Shale, which may be subjected to shale-gas exploration by use of hydraulic fracturing. The SVCD has sought technical assistance from the U.S. Geological Survey to characterize baseline water quality at the SVCD well field so that future changes in water quality (if any) and the cause of those changes (including mine leachate and hydraulic fracturing) can be identified.

  13. Adapted hydropower-driven water supply system: assessment of an underground application in an Indonesian karst area

    NASA Astrophysics Data System (ADS)

    Oberle, P.; Ikhwan, M.; Stoffel, D.; Nestmann, F.

    2016-09-01

    Populated karst landscapes can be found all over the world, although their natural boundary conditions mostly lead to distinct challenges regarding a sustainable water supply. Especially in developing and emerging countries, this situation aggravates since appropriate technologies and water management concepts are rarely available. Against this background, the interdisciplinary, German-Indonesian joint project " Integrated Water Resources Management (IWRM) Indonesia", funded by the German Federal Ministry of Education and Research (BMBF), focused on the development and exemplary implementation of adapted techniques to remedy the partly severe water scarcity in the region Gunung Sewu. This karst area, widely known as " Java's poorhouse", is located on the southern coast of Java Island and distinctly suffers from the mentioned constraints. Under the aegis of the Karlsruhe Institute of Technology (KIT), the conceptual and technical achievements of the "IWRM Indonesia" joint research project are characterized by a high potential for multiplication not only for karst areas but also for non-karst regions. One of the project's major accomplishments is the erection of an innovative hydropower-driven water supply facility located in a karst cave 100 m below ground and continuously supplying tens of thousands of people with fresh water. Referring to the plant's innovative character and the demanding conditions on-site, the implementation was a highly iterative process leading to today's autonomous operation by an Indonesian public authority. Based on the experiences gained during design, construction, operation and monitoring phase, this paper introduces an implementation approach for adapted technologies as well as a comprising technical and economical assessment of the plant's operation.

  14. Napa Earthquake impact on water systems

    NASA Astrophysics Data System (ADS)

    Wang, J.

    2014-12-01

    South Napa earthquake occurred in Napa, California on August 24 at 3am, local time, and the magnitude is 6.0. The earthquake was the largest in SF Bay Area since the 1989 Loma Prieta earthquake. Economic loss topped $ 1 billion. Wine makers cleaning up and estimated the damage on tourism. Around 15,000 cases of lovely cabernet were pouring into the garden at the Hess Collection. Earthquake potentially raise water pollution risks, could cause water crisis. CA suffered water shortage recent years, and it could be helpful on how to prevent underground/surface water pollution from earthquake. This research gives a clear view on drinking water system in CA, pollution on river systems, as well as estimation on earthquake impact on water supply. The Sacramento-San Joaquin River delta (close to Napa), is the center of the state's water distribution system, delivering fresh water to more than 25 million residents and 3 million acres of farmland. Delta water conveyed through a network of levees is crucial to Southern California. The drought has significantly curtailed water export, and salt water intrusion reduced fresh water outflows. Strong shaking from a nearby earthquake can cause saturated, loose, sandy soils liquefaction, and could potentially damage major delta levee systems near Napa. Napa earthquake is a wake-up call for Southern California. It could potentially damage freshwater supply system.

  15. Livermore study says oil leaks not severe

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Patrick, L.

    The Petroleum Marketers Association of America (PMAA), which is working to reform the federal Leaking Underground Storage Tank program, got some strong ammunition last month. A study that the Lawrence Livermore National Laboratory performed for the California State Water Resources Control Board has found that the environmental threat of leaks is not as severe as formerly thought. The study said: such leaks rarely jeopardize drinking water; fuel hydrocarbons have limited impacts on health, the environment, and groundwater; and cleanups often are done contrary to the knowledge and experience gained from prior remediations. As a result of the study, Gov. Petemore » Wilson ordered California cleanups halted at sites more than 250 feet from drinking water supplies.« less

  16. Groundwater utilization through the centuries focusing οn the Hellenic civilizations

    NASA Astrophysics Data System (ADS)

    Angelakis, Andreas N.; Voudouris, Konstantinos S.; Mariolakos, Ilias

    2016-08-01

    Groundwater has been utilized since the Prehistoric times. Water supply of some Minoan settlements on the eastern side of the island of Crete (Greece) was based on groundwater. Later on, many wells were constructed in several areas of Greece and their use expanded through subsequent periods. The greatest achievement in groundwater exploitation by ancient Greeks was the construction of long underground galleries or qanats, which collected water from springs and alluvial deposits. In Classical times, most of the wells were on private properties and their owners were forced by regulations to maintain the wells in good condition and ready for use in wartime. During that period, the first scientific theories of Aristotle and Theophrastus were developed in regards to hydrological phenomena, and the processes involved in the formation of surface water and groundwater were clarified. Wells played a major part in urban water supply during the Roman period, in which famous aqueducts were constructed to transfer water; however, several regions of Greece were self-sufficient in water, supplied by many wells from the Prehistoric to the Byzantine period. People understood the local geological conditions and, according to their culture, constructed and managed their own types of wells. In addition to the wells and aqueducts, the hydraulic technology included cisterns to store rainwater, and systems to capture spring water for transport by aqueducts. The examples of hydro-technologies and water management practices described in this paper may have some relevance for water engineering even in modern times.

  17. Environmental health aspects of drinking water-borne outbreak due to karst flooding: case study.

    PubMed

    Dura, Gyula; Pándics, Tamás; Kádár, Mihály; Krisztalovics, Katalin; Kiss, Zoltánné; Bodnár, Judit; Asztalos, Agnes; Papp, Erzsébet

    2010-09-01

    Climate change may increase the incidence of waterborne diseases due to extreme rainfall events, and consequent microbiological contamination of the water source and supply. As a result of the complexity of the pathways from the surface to the consumer, it is difficult to detect an association between rainfall and human disease. The water supply of a Hungarian city, Miskolc (174,000 inhabitant), is mainly based on karstic water, a vulnerable underground water body. A large amount of precipitation fell on the catchment area of the karstic water source, causing an unusually strong karstic water flow and flooding, and subsequent microbiological contamination. The presence of several potential sources of contamination in the protective zone of the karstic water source should be emphasized. The water supplier was unprepared to treat the risk of waterborne outbreak caused by an extreme weather event. Public health intervention and hygienic measures were taken in line with epidemiological actions, focusing on the protection of consumers by providing safe drinking water. The contamination was identified, and measures were taken for risk reduction and prevention. This case study underlines the increasing importance of preparedness for extreme water events in order to protect the karstic water sources and to avoid waterborne outbreaks.

  18. 40 CFR 35.683 - Annual amount reserved by EPA.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... the underground water source protection funds each year for underground water source protection grants to Tribes under section 1443(b) of the Safe Drinking Water Act. ... ASSISTANCE STATE AND LOCAL ASSISTANCE Environmental Program Grants for Tribes Underground Water Source...

  19. 40 CFR 35.683 - Annual amount reserved by EPA.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... the underground water source protection funds each year for underground water source protection grants to Tribes under section 1443(b) of the Safe Drinking Water Act. ... ASSISTANCE STATE AND LOCAL ASSISTANCE Environmental Program Grants for Tribes Underground Water Source...

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    The Adrian Municipal Well Field site is in Adrian, Nobles County, Minnesota, a city which relies solely on ground water for its municipal water supply. In 1983 the State detected VOC contamination in two of the six wells at the site, and by 1985 the city had replaced the VOC-contaminated wells with two new wells. Subsequent ground water sampling indicated that petroleum releases from underground storage tanks (UST) are sources for soil and ground water contamination. Although ground water contaminant concentrations exceed Federal and State drinking water and surface water standards, no further action will be taken by the Superfundmore » program because the program does not have the authority to address clean up of petroleum releases. EPA will, however, formally transfer the site to its UST program in October 1989 for further action. There are no costs associated with this remedial action.« less

  1. Final Environmental Assessment for Construction and Operation of a Water Treatment Building at Cavalier Air Force Station, North Dakota

    DTIC Science & Technology

    2010-07-01

    complete, the open area around the Building and new underground electrical supply would be landscaped with native vegetation. The installation would...the AFS range from 1,130 feet above mean sea level in the eastern portion to 1,180 feet in the western part. The regional gradient is to the northeast...recreation, and irrigation. The Pembina River starts in the Turtle Mountains and enters the Red River of the North at Pembina. It drains 1,960

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bollinger, J.M.; Kaplan, N.; Wilkening, H.A. Jr.

    AAI Corporation designed, constructed, and operated a solar heating system to provide hot water for curing concrete blocks at the York Building Products Co., Inc.'s new manufacturing facility near Harrisburg, PA. The objective of Phase III of this program was to operate, collect data, and evaluate the solar system for a three-year period. The solar facility utilizes 35 collectors with a total aperture area of 8,960 ft/sup 2/. The system is designed to deliver a water/ethylene glycol solution at 200/sup 0/F to a heat exchanger, which, in turn, supplies water at 180/sup 0/F to a rotoclave (underground tank) for themore » concrete-block curing process. A fossil-fuel boiler system also supplies the rotoclave with processed hot water to supplement the solar system. The system was operational 92.5% of the days during which the data acquisition system was functional. Sufficient solar heating was available to deliver hot water to the heat exchanger on 448 days, or 81.8% of the days on which reliable data was recorded. Total fuel saved during the three-year period was 10,284 gallons. Thus, this program has successfully demonstrated the technical feasibility of generating industrial process hot water with solar energy.« less

  3. Bangladesh arsenic mitigation programs: lessons from the past

    PubMed Central

    Milton, Abul Hasnat; Hore, Samar Kumar; Hossain, Mohammad Zahid; Rahman, Mahfuzar

    2012-01-01

    Ensuring access to safe drinking water by 2015 is a global commitment by the Millennium Development Goals (MDGs). In Bangladesh, significant achievements in providing safe water were made earlier by nationwide tubewell-installation programme. This achievement was overshadowed in 1993 by the presence of arsenic in underground water. A total of 6 million tubewells have been tested for arsenic since then, the results of which warranted immediate mitigation. Mitigation measures included tubewell testing and replacing; usage of deeper wells; surface water preservation and treatment; use of sanitary dug wells, river sand and pond sand filters; rainwater collection and storage; household-scale and large-scale arsenic filtrations; and rural pipeline water supply installation. Shallow tubewell installation was discouraged. Efforts have been made to increase people's awareness. This paper describes the lessons learned about mitigation efforts by the authors from experience of arsenic-related work. In spite of national mitigation plans and efforts, a few challenges still persist: inadequate coordination between stakeholders, differences in inter-sectoral attitudes, inadequate research to identify region-specific, suitable safe water options, poor quality of works by various implementing agencies, and inadequate dissemination of the knowledge and experiences to the people by those organizations. Issues such as long-time adaptation using ground water, poor surface water quality including bad smell and turbidity, and refusal to using neighbor's water have delayed mitigation measures so far. Region-specific mitigation water supply policy led by the health sector could be adopted with multisectoral involvement and responsibility. Large-scale piped water supply could be arranged through Public Private Partnerships (PPP) in new national approach. PMID:22558005

  4. Bangladesh arsenic mitigation programs: lessons from the past.

    PubMed

    Milton, Abul Hasnat; Hore, Samar Kumar; Hossain, Mohammad Zahid; Rahman, Mahfuzar

    2012-01-01

    Ensuring access to safe drinking water by 2015 is a global commitment by the Millennium Development Goals (MDGs). In Bangladesh, significant achievements in providing safe water were made earlier by nationwide tubewell-installation programme. This achievement was overshadowed in 1993 by the presence of arsenic in underground water. A total of 6 million tubewells have been tested for arsenic since then, the results of which warranted immediate mitigation. Mitigation measures included tubewell testing and replacing; usage of deeper wells; surface water preservation and treatment; use of sanitary dug wells, river sand and pond sand filters; rainwater collection and storage; household-scale and large-scale arsenic filtrations; and rural pipeline water supply installation. Shallow tubewell installation was discouraged. Efforts have been made to increase people's awareness. This paper describes the lessons learned about mitigation efforts by the authors from experience of arsenic-related work. In spite of national mitigation plans and efforts, a few challenges still persist: inadequate coordination between stakeholders, differences in inter-sectoral attitudes, inadequate research to identify region-specific, suitable safe water options, poor quality of works by various implementing agencies, and inadequate dissemination of the knowledge and experiences to the people by those organizations. Issues such as long-time adaptation using ground water, poor surface water quality including bad smell and turbidity, and refusal to using neighbor's water have delayed mitigation measures so far. Region-specific mitigation water supply policy led by the health sector could be adopted with multisectoral involvement and responsibility. Large-scale piped water supply could be arranged through Public Private Partnerships (PPP) in new national approach.

  5. The Study of Impacts of Water Transferring From Wet Regions To Dry Regions In Iran

    NASA Astrophysics Data System (ADS)

    Motiee-Homayoun, Dr.; Ghomashchi, Dr.

    Iran, with a very diverse ecology and different climate has been classified as a dry- semidry region. Iran's annual average of rain-fall is about 250 mm, while this figure is more than 1000 mm in north and less than 100 mm in the south of the country. Overall, Iran's water resources are low. Rapid population growth, economic growth together with significant urban development, in recent decades, has led to underestimate high demands for water. Therefore, water shortage has been considered more obviously. Such an important scare is rather serious in central and eastern regions of the country. This problem has been determined as a serious challenge for Iran's government and national water authorities, in particular. Although, drinking water supply is only 6 percent of total water resources, due to direct socio-political impacts, drinking water supply, in both quality and quantity, is more serious and important than agricultural water demands. Accordingly, for the following reasons: 1) Desperation and diversity of geographical conditions of urban areas 2) Low access to underground water 3) Inadequate quality surface water supply Difficulties and the costs of supplying urban water in Iran have been sharply increased. Presently, due to unconstrained consuming underground water and negative balance in most under ground resources of the country, more specifically in central and eastern regions, water supply from groundwater resources is very risky and misleading. Furthermore, other reason such as rapid urban population growth and changes in people's every day life and their consumption patterns increase both water consumption and waste water in the circumstances of inadequate sewage systems, make a vast source of pollution for water resources. Due to the influence of extended See (Salty) water, in southern provinces, near to Persian Gulf, accessibility to fresh water is rather difficult and in many cases only after tens of kilometers far from the see, fresh water could be available. In this situation, water transformation from wet areas (with good water resources) to dried and desert regions of the country has been identified as a necessary and reasonable policy to tacklewater shortage. Mediterain climate and mountains in north, west and southwest regions of Iran grant a benefit of high level rate of rainfall, several deep and long rivers, and large capacity of groundwater resources in these areas. Existence of such rivers and water resources, especially a big river of Karoon in southwest, strengthens the goal of constructing hydraulic structures in order to transfer water fro m wet areas to central and eastern areas of the country. This goal has led to planning and implementing of several large and high cost projects. Experts of water affairs, believe that although drinking water supply is one of the most crucial missions of the government, it should also be noted that transformation huge amount of water from an area to another area, with a very long distant, undoubtedly, will cause significant environmental impacts in future. Therefore, decision making and implementing such strategic projects needs a very precise consideration and accurate cost-benefit analyzes. On the one hand, through a socio- economic approach, implementation of such big projects for water transferring requires a great amount of investment and a long period to complete, and benefit peoples. So in many cases multi-purpose and multi- dimensional projects should be considered carefully. On the other hand, water supply for some provinces is vital. In most identified areas, water scarcity is the main cause of urban decline, economic problems and finally loosing population because of emigration. Thus, fresh water should be supplied for these provinces at the earliest possible. This paper is an attempt to identify, define and explain the characteristics and specification of all projects for transferring in different parts of Iran. Generally, advantages and disadvantages of these projects concerning economic and environmental impacts will be clarified. For instance, taking water from Karoon River and transferring to central region of country has changed the percentage of its quality in seashore and effect ecology of seaside and coastal areas. The importance of these projects will be more obvious, when people's demands, in dried regions, increase rapidly. Recently, this matter has passed internal border of the country, considering water transferring to other countries in Persian Gulf such as Kuwait and Qatar. Key words: water supply ­ transferring system ­ Iran ­ water shortage

  6. Geology and underground waters of the Arkansas Valley in eastern Colorado

    USGS Publications Warehouse

    Darton, N.H.

    1906-01-01

    In the valley of Arkansas River in southeastern Colorado there is an area of considerable extent in which artesian flows are available. During the last ten years numerous wells have been sunk to develop this important resource and, in most cases in the lower lands, abundant water supplies have been obtained. The principal water-bearing bed is the "Dakota" formation, which consists of two sheets of porous sandstone separated by a small body of clay and overlain in the greater portion of the area by a mass of impervious shales. The sandstones receive their waters from, rainfall and from the sinking of streams along the foothills of the Rocky Mountains and on some of the higher slopes south of the Arkansas Valley. In the passage of this sandstone underground, the waters which it contains are held down by the overlying shales, but, as some of the sandstone outcrops are at relatively low levels to the east only a moderate head or pressure is sustained. On account of this low head, artesian flows are available only in the lower lands, and one of the principal objects of this investigation has been the determination of the area in which flows are to be expected. The "Dakota" sandstone and associated formations do not lie level, or even slope regularly to the east, but are flexed into low arches and shallow troughs of considerable complexity of configuration. Accordingly, in investigating this source of water supply, it has been necessary to ascertain the structure and distribution of the various formations in order to indicate the variations in depth to the water-bearing stratum. The principal results of these investigations are set forth: (1) In the geologic map (Pl. VI), which shows the distribution of the formations on the surface; (2) in the map, Pl. XXV, which shows the depth to the water-bearing horizon, the area in which flows are expected, the head of the underground waters, and other features, and (3) in the cross sections (Pls. VII and XXIII), which show the principal underground features. The investigation has been in progress for several years and is an extension of the preliminary examination of the region by G. K. Gilbert in 1894 and 1895.For the western portion of the area the maps and texts of the Pueblo, Elmoro, Walsenburg, Spanish Peaks, and Pikes Peak folios have been utilized as far as practicable. For the central and eastern portions the larger features of the geology have been specially mapped, and considerable detailed mapping has been done in the region south and southeast of Canyon and Colorado Springs. In the field work I have been assisted by Mr. C. A. Fisher, who has examined in detail the Nepesta quadrangle and contributed numerous other data. Dr. W. S. Tangier Smith and Messrs. C. E. Sicbenthal and W. T. Lee have made observations in certain areas. Much valuable information respecting wells has been furnished by Mr. William Archer, of the Atchison, Topeka and Santa Fe Railway Company, and Mr. C. H. McVay, well driller at Rocky Ford.

  7. Development of a Strategic Framework for Drought Management

    NASA Astrophysics Data System (ADS)

    Kang, Jaewon; Kim, Sooyoung; Suh, Aesook; Cho, Younghyun

    2017-04-01

    A drought starts with lack of precipitation; as the deficit of precipitation is prolonged, the loss of water influences on the amount of soil water because of evapotranspiration. In addition, the decreased runoff of surface and underground water also reduces discharge in rivers and storage in reservoirs; these reductions then lead to the decline in the supply capability of water resources supply facilities. Therefore, individuals may experience a given drought differently depending on their circumstances. In an area with a metropolitan water supply network that draws water from a multipurpose dam, residents might not realize that a meteorological drought is present since they are provided with sufficient water. Similar situation might occur in farmlands for which an irrigation system supplies water from an agricultural reservoir. In Korea, several institutions adopt each drought indices in their roles. Since March 2016, the Ministry of Public Safety and Security, via inter-ministerial cooperation, has been classifying and announcing drought situations in each administrative district of Korea into three types, meteorological, agricultural, or hydrological droughts, with three levels such as 'caution,' 'serious,' or 'very serious.' Deriving the drought index considering storage facilities and other factors and expressing them in three categories are valid as methods. However, the current method that represent the drought situation in an administrative district as a whole should be improved to recognize the drought situation more realistically and to make appropriate strategic responses. This study designs and implements a pilot model of a framework that re-establishes zones for drought situation representation, taking water usage and water supply infrastructure into account based on land use maps. In addition, each resulting district is provided with statistical indices that can assist in the application of appropriate drought indices and the understanding of situations. In the framework, different areas classified as forest/grassland, paddy fields with an irrigation system, paddy/dry fields relying on rainwater, areas with a metropolitan or provincial water supply, or areas with other residential/industrial water supply, in a single administrative district have different values for meteorological, agricultural, or hydrological droughts. And the situation can be analyzed on a daily basis to take into account areas with a possibility that the drought may be relieved by a short-term downpour or similar event. Keywords: drought management, strategic framework, drought indices

  8. Biodegradation of roxarsone by a bacterial community of underground water and its toxic impact.

    PubMed

    Mafla, S; Moraga, R; León, C G; Guzmán-Fierro, V G; Yañez, J; Smith, C T; Mondaca, M A; Campos, V L

    2015-08-01

    Roxarsone is included in chicken food as anticoccidial and mainly excreted unchanged in faeces. Microorganisms biotransform roxarsone into toxic compounds that leach and contaminate underground waters used for human consumption. This study evaluated roxarsone biotransformation by underground water microorganisms and the toxicity of the resulting compounds. Underground water from an agricultural field was used to prepare microcosms, containing 0.05 mM roxarsone, and cultured under aerobic or anaerobic conditions. Bacterial communities of microcosms were characterized by PCR-DGGE. Roxarsone degradation was measured by HPLC/HG/AAS. Toxicity was evaluated using HUVEC cells and the Toxi-ChromoTest kit. Roxarsone degradation analysis, after 15 days, showed that microcosms of underground water with nutrients degraded 90 and 83.3% of roxarsone under anaerobic and aerobic conditions, respectively. Microcosms without nutrients degraded 50 and 33.1% under anaerobic and aerobic conditions, respectively. Microcosms including nutrients showed more roxarsone conversion into toxic inorganic arsenic species. DGGE analyses showed the presence of Proteobacteria, Firmicutes, Actinobacteria, Planctomycetes and Spirochaetes. Toxicity assays showed that roxarsone biotransformation by underground water microorganisms in all microcosms generated degradation products toxic for eukaryotic and prokaryotic cells. Furthermore, toxicity increased when roxarsone leached though a soil column and was further transformed by the bacterial community present in underground water. Therefore, using underground water from areas where roxarsone containing manure is used as fertilizer might be a health risk.

  9. Technology Transfer Opportunities: Automated Ground-Water Monitoring

    USGS Publications Warehouse

    Smith, Kirk P.; Granato, Gregory E.

    1997-01-01

    Introduction A new automated ground-water monitoring system developed by the U.S. Geological Survey (USGS) measures and records values of selected water-quality properties and constituents using protocols approved for manual sampling. Prototypes using the automated process have demonstrated the ability to increase the quantity and quality of data collected and have shown the potential for reducing labor and material costs for ground-water quality data collection. Automation of water-quality monitoring systems in the field, in laboratories, and in industry have increased data density and utility while reducing operating costs. Uses for an automated ground-water monitoring system include, (but are not limited to) monitoring ground-water quality for research, monitoring known or potential contaminant sites, such as near landfills, underground storage tanks, or other facilities where potential contaminants are stored, and as an early warning system monitoring groundwater quality near public water-supply wells.

  10. Increasing Awareness of Sustainable Water Management for Future Civil Engineers

    NASA Astrophysics Data System (ADS)

    Ilic, Suzana; Karleusa, Barbara; Deluka-Tibljas, Aleksandra

    2010-05-01

    There are more than 1.2 billion people around the world that do not have access to drinking water. While there are plans under the United Nations Millennium Development Goals to halve this number by 2015, there are a number of regions that will be exposed to water scarcity in the coming future. Providing sufficient water for future development is a great challenge for planners and designers of water supply systems. In order to design sustainable water supplies for the future, it is important to learn how people consume water and how water consumption can be reduced. The education of future civil engineers should take into account not only technical aspects of the water supply but also the accompanying social and economical issues, and appreciated the strengths and weaknesses of traditional solutions. The Faculty of Civil Engineering, at the University of Rijeka, has begun incorporating a series of activities that engage undergraduate students and the local community to develop a mutual understanding of the future needs for sustainable management. We present one of the activities, collaboration with the Lancaster Environment Centre at Lancaster University in the UK through the field course Water and environmental management in Mediterranean context. The course, which is designed for the Lancaster University geography students, features a combination of field trips and visits to provide an understanding of the socio-economic and environmental context of water management in two counties (Istra and Primorsko-Goranska). Students from Lancaster visit the Croatian water authority and a regional water company, where they learn about current management practices and problems in managing water supplies and demand through the year. They make their own observations of current management practices in the field and learn about water consumption from the end users. One day field visit to a village in the area that is still not connected to the main water supply system is organised together with civil engineering students from the University of Rijeka. The aims of this field visit are: to learn about traditional water supply from an underground storage of rain water called cisterna; and to find out from inhabitants about their current water usage habits and expectations, and how these might change when they get water from the main water supply system. This joint activity has been beneficial for both groups of students. The engineering students become aware of the importance of the social aspects in designing the water supply system, while the geography students learn about the engineering challenges entailed. Both groups learn that water consumption increases with the provision of water through pipeline systems and that this needs to be taken into account in the design of water supply and management of water resources. Importantly, they learn the benefits of traditional sustainable water supply methods, which could be implemented as primary or additional sources of water supply in other areas.In summary, both groups of students develop their professional knowledge and skills as well as generic and transferable skills, which are very important for those who will continue to a career in the design and management of water systems.

  11. 40 CFR 144.79 - General.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... subpart and elsewhere in this part are to protect underground sources of drinking water and are part of the Underground Injection Control (UIC) Program established under the Safe Drinking Water Act. This... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) UNDERGROUND...

  12. 40 CFR 144.79 - General.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... subpart and elsewhere in this part are to protect underground sources of drinking water and are part of the Underground Injection Control (UIC) Program established under the Safe Drinking Water Act. This... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) UNDERGROUND...

  13. Competing Uses of Underground Systems Related to Energy Supply: Applying Single- and Multiphase Simulations for Site Characterization and Risk-Analysis

    NASA Astrophysics Data System (ADS)

    Kissinger, A.; Walter, L.; Darcis, M.; Flemisch, B.; Class, H.

    2012-04-01

    Global climate change, shortage of resources and the resulting turn towards renewable sources of energy lead to a growing demand for the utilization of subsurface systems. Among these competing uses are Carbon Capture and Storage (CCS), geothermal energy, nuclear waste disposal, "renewable" methane or hydrogen storage as well as the ongoing production of fossil resources like oil, gas, and coal. Besides competing among themselves, these technologies may also create conflicts with essential public interests like water supply. For example, the injection of CO2 into the underground causes an increase in pressure reaching far beyond the actual radius of influence of the CO2 plume, potentially leading to large amounts of displaced salt water. Finding suitable sites is a demanding task for several reasons. Natural systems as opposed to technical systems are always characterized by heterogeneity. Therefore, parameter uncertainty impedes reliable predictions towards capacity and safety of a site. State of the art numerical simulations combined with stochastic approaches need to be used to obtain a more reliable assessment of the involved risks and the radii of influence of the different processes. These simulations may include the modeling of single- and multiphase non-isothermal flow, geo-chemical and geo-mechanical processes in order to describe all relevant physical processes adequately. Stochastic approaches have the aim to estimate a bandwidth of the key output parameters based on uncertain input parameters. Risks for these different underground uses can then be made comparable with each other. Along with the importance and the urgency of the competing processes this may lead to a more profound basis for a decision. Communicating risks to stake holders and a concerned public is crucial for the success of finding a suitable site for CCS (or other subsurface utilization). We present and discuss first steps towards an approach for addressing the issue of competitive utilization of the subsurface and the required process of communication between scientists, engineers, policy makers, and societies.

  14. Comprehensive surface geophysical investigation of karst caves ahead of the tunnel face: A case study in the Xiaoheyan section of the water supply project from Songhua River, Jilin, China

    NASA Astrophysics Data System (ADS)

    Bin, Liu; Zhengyu, Liu; Shucai, Li; Lichao, Nie; Maoxin, Su; Huaifeng, Sun; Kerui, Fan; Xinxin, Zhang; Yonghao, Pang

    2017-09-01

    This paper describes the application of a comprehensive surface geophysical investigation of underground karst systems ahead of the tunnel face in the Xiaoheyan section in the main line of the water supply project from Songhua River, located in Jilin, China. To make an accurate investigation, Surface Electrical Resistivity Tomography (S-ERT), Transient Electromagnetic Method (TEM), Geological Drilling (Geo-D) and Three-dimensional Cross-hole Electrical Resistivity Tomography (3D cross-hole ERT) were applied to gain a comprehensive interpretation. To begin with, S-ERT and TEM are adopted to detect and delineate the underground karst zone. Based on the detection results, surface and in-tunnel Geo-D are placed in major areas with more specific and accurate information gained. After that, survey lines of 3D cross-hole ERT are used to conduct detailed exploration towards underground karst system. In the comprehensive investigation, it is the major question to make the best of prior information so as to promote the quality of detection. The paper has put forward strategies to make the full use of effective information in data processing and the main ideas of those strategies include: (1) Take the resistivity distribution of the subsurface stratum gained by S-ERT inversion as the initial model of TEM inversion; (2) Arrange borehole positions with the results of S-ERT and TEM. After that, gain more accurate information about resistivity of subsurface stratum using those boreholes located; (3) Through the comprehensive analysis of the information about S-ERT, TEM and Geo-D, set the initial model of 3D cross-hole resistivity inversion and meanwhile, gain the variation range of stratum resistivity. At last, a 3D cross-hole resistivity inversion based on the incorporated initial model and inequality constraint is conducted. Constrained inversion and joint interpretation are realized by the effective use of prior information in comprehensive investigation, helping to suppress the non-uniqueness problem of inversion so as to raise its reliability. In this way, a 3D detailed model of underground karst system which is 30 m ahead of tunnel face is finally formed. At the end of the paper, there is a geological sketch of the revealed karst caves, which illustrates the effectiveness of the presented strategy. To sum up, in the comprehensive investigation of underground karst caves, the integrated use of prior information can help to yield more accurate and detailed results.

  15. 40 CFR 146.5 - Classification of injection wells.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ..., an underground source of drinking water. (2) Other industrial and municipal disposal wells which... underground source of drinking water. (3) Radioactive waste disposal wells which inject fluids below the lowermost formation containing an underground source of drinking water within one quarter mile of the well...

  16. 40 CFR 146.5 - Classification of injection wells.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ..., an underground source of drinking water. (2) Other industrial and municipal disposal wells which... underground source of drinking water. (3) Radioactive waste disposal wells which inject fluids below the lowermost formation containing an underground source of drinking water within one quarter mile of the well...

  17. 40 CFR 146.5 - Classification of injection wells.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ..., an underground source of drinking water. (2) Other industrial and municipal disposal wells which... underground source of drinking water. (3) Radioactive waste disposal wells which inject fluids below the lowermost formation containing an underground source of drinking water within one quarter mile of the well...

  18. 40 CFR 146.5 - Classification of injection wells.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., an underground source of drinking water. (2) Other industrial and municipal disposal wells which... underground source of drinking water. (3) Radioactive waste disposal wells which inject fluids below the lowermost formation containing an underground source of drinking water within one quarter mile of the well...

  19. 40 CFR 146.5 - Classification of injection wells.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., an underground source of drinking water. (2) Other industrial and municipal disposal wells which... underground source of drinking water. (3) Radioactive waste disposal wells which inject fluids below the lowermost formation containing an underground source of drinking water within one quarter mile of the well...

  20. Factors associated with sources, transport, and fate of volatile organic compounds and their mixtures in aquifers of the United States

    USGS Publications Warehouse

    Squillace, P.J.; Moran, M.J.

    2007-01-01

    Factors associated with sources, transport, and fate of volatile organic compounds (VOCs) in groundwater from aquifers throughout the United States were evaluated using statistical methods. Samples were collected from 1631 wells throughout the conterminous United States between 1996 and 2002 as part of the National Water-Quality Assessment (NAWQA) Program of the U.S. Geological Survey. Water samples from wells completed in aquifers used to supply drinking water were analyzed for more than 50 VOCs. Wells were primarily rural domestic water supplies (1184), followed by public water supplies (216); the remaining wells (231) supplied a variety of uses. The median well depth was 50 meters. Age-date information shows that about 60% of the samples had a fraction of water recharged after 1953. Chloroform, toluene, 1,2,4-trimethylbenzene, and perchloroethene were some of the frequently detected VOCs. Concentrations generally were less than 1 ??g/L. Source factors include, in order of importance, general land-use activity, septic/sewer density, and sites where large concentrations of VOCs are potentially released, such as leaking underground storage tanks. About 10% of all samples had VOC mixtures that were associated with concentrated sources; 20% were associated with dispersed sources. Important transport factors included well/screen depth, precipitation/groundwater recharge, air temperature, and various soil characteristics. Dissolved oxygen was strongly associated with VOCs and represents the fate of many VOCs in groundwater. Well type (domestic or public water supply) was also an important explanatory factor. Results of multiple analyses show the importance of (1) accounting for both dispersed and concentrated sources of VOCs, (2) measuring dissolved oxygen when sampling wells to help explain the fate of VOCs, and (3) limiting the type of wells sampled in monitoring networks to avoid unnecessary variance in the data, or controlling for this variance during data analysis.

  1. Seismic Signals Recorded During Artificial and Natural Karst Recharge Events

    NASA Astrophysics Data System (ADS)

    Bilek, S. L.; Luhmann, A. J.; Diniakos, R. S.; Morton, E.; Rinehart, A. J.; Alexander, E. C., Jr.; Alexander, S. C.; Larsen, M.; Green, J. A.

    2016-12-01

    Seismology has recently been used to explore a variety of surficial processes, including tracking landslides, glaciers, and river flow. The seismic data collected can provide useful information about these flow processes, particularly in areas where other flow-related observations are difficult to make. Underground flow through karst aquifers is an area of significant interest, where most of the flow occurs through preferential flow conduits whose locations are largely unknown. We investigate seismic signals generated by both controlled and natural recharge into a karst aquifer system located near Bear Spring, near Eyota, MN, USA. The controlled recharge experiments involved injecting a pool full of water ( 13,000 L) into a dry overflow spring, which then flowed underground until it was discharged at Bear Spring. The natural recharge fortuitously involved a large rainstorm that supplied over 2 inches of rain in a few hour period, which caused the overflow spring to start flowing and total discharge to increase from a background of 100 L/s to 300 L/s. These events were recorded by 12 seismometers (11 short period and 1 broadband with 500 Hz sampling rate) all placed within the 4500 m2 area containing the dry overflow spring and predicted underground flow path. Spectrograms for the artificial and natural recharge events show significant seismic energy over a broad frequency range (few to nearly 220 Hz) during the periods of artificial recharge, largely contained during the period of water injection. Stations closest to Bear Spring see peak seismic energy in the 20-30 Hz range during these tests, likely related to changes in the underground water flow. During the natural recharge event, we find much longer duration of seismic energy over the broad frequency range. We compare these seismic results with discharge measurements conducted during all tests at Bear Spring, as well as with rainfall measurements recorded for the natural recharge event.

  2. Ground-water resources of Kansas

    USGS Publications Warehouse

    Moore, R.C.; Lohman, S.W.; Frye, J.C.; Waite, H.A.; McLaughlin, Thad G.; Latta, Bruce

    1940-01-01

    Importance of ground-water resources.—The importance of Kansas' ground-water resources may be emphasized from various viewpoints and in different ways. More than three-fourths of the public water supplies of Kansas are obtained from wells. In 1939, only 60 out of 375 municipal water supplies in Kansas, which is 16 percent, utilized surface waters. If the water wells of the cities and those located on all privately owned land in the state were suddenly destroyed, making it necessary to go to streams, springs, lakes (which are almost all artificial), and ponds for water supply domestic, stock, and industrial use, there would be almost incalculable difficulty and expense. If one could not go to springs, or dig new wells, or use any surface water derived from underground flow, much of Kansas would become uninhabitable.  These suggested conditions seem absurd, but they emphasize our dependence on ground-water resources. Fromm a quantitative standpoint, ground-water supplies existent in Kansas far outweigh surface waters that are present in the state at any one time. No exact figures for such comparison can be given, but, taking 384 square miles as the total surface water area of the state and estimating an average water depth of five feet, the computed volume of surface waters is found to be 1/100th of that of the conservatively estimated ground-water storage in Kansas. The latter takes account only of potable fresh water and is based on an assumed mean thickness of ten feet of reservoir having an effective porosity of twenty percent. It is to be remembered, however, that most of the surface water is run-off, which soon leaves the state, stream valleys being replenished from rainfall and flow from ground-water reservoirs. Most of the ground-water supplies, on the other hand, have existed for many years with almost no appreciable movement--in fact, it is reasonably certain that some well water drawn from beneath the surface of Kansas in 1940 represents rainfall in this region at time before the first white man entered Kansas, even before the visit of Coronado in the 16th century. Most ground water is to be regarded as water in storage rather than water in transit.   

  3. The Socio-hydrology of Bangalore's Lake System and implications for Urban Water Security

    NASA Astrophysics Data System (ADS)

    Srinivasan, V.; Roy, S.

    2017-12-01

    Bengaluru city has experienced unprecedented growth in recent decades. If the city is to sustain growth and claim its position as a "global" high-tech city, it must be able to secure sufficient water supply and also create a healthy livable environment. With the city's many lakes vanishing due to rapid urbanisation, depletion of groundwater as a result of overuse in the peri-urban areas, and lack of proper underground drainage system and sewage treatment plants, Bangalore is now grappling with issues of imminent water crisis, inequitable access to water supply, and public health hazards. In this context, the restoration of Bangalore's lakes has been promoted as a panacea for its flooding, water stress, and wastewater problems. It has been argued that lakes can store storm water and recycled wastewater and avoid the need for potentially destructive, expensive schemes that may destroy biodiversity rich aquatic ecosystems and forests. Bangalore's lakes are linked by the drainage channels to form a cascade; overflow from each lake flows to the next lake downstream. Yet, most efforts have tended to view the lakes in isolation. This study of the hydrology of Bangalore's lake system in its entirety simulates the lake system as a whole. The study explores approaches to management and theor impact on urban water security.

  4. Water resources inventory of Connecticut Part 1: Quinebaug River basin

    USGS Publications Warehouse

    Randall, Allan D.; Thomas, Mendall P.; Thomas, Chester E.; Baker, John A.

    1966-01-01

    The Quinebaug River basin is blessed with a relatively abundant supply of water of generally good quality which is derived from precipitation that has fallen on the basin. Annual precipitation has ranged from about 30 to 67 inches and has averaged about 45 inches over a 44-year period. Approximately 21 inches of water are returned to the atmosphere each year by evaporation and transpiration; the remainder of the annual precipitation either flows overland to streams or percolates downward to the water table and ultimately flows out of the basin in the Quinebaug River. During the autumn and winter months precipitation normally is sufficient to cause a substantial increase in the amount of water stored underground and in surface reservoirs within the basin, whereas in the summer most of the precipitation is lost through evaporation and transpiration, resulting in sharply reduced streamflow and lowered ground-water levels.

  5. 30 CFR 72.630 - Drill dust control at underground areas of underground mines.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... dust control at underground areas of underground mines. (a) Dust resulting from drilling in rock shall... condition. Dust collectors approved under Part 33—Dust Collectors for Use in Connection with Rock Drilling... the purpose of this section. (c) Water control. Water used to control dust from drilling rock shall be...

  6. 30 CFR 72.630 - Drill dust control at underground areas of underground mines.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... dust control at underground areas of underground mines. (a) Dust resulting from drilling in rock shall... condition. Dust collectors approved under Part 33—Dust Collectors for Use in Connection with Rock Drilling... the purpose of this section. (c) Water control. Water used to control dust from drilling rock shall be...

  7. 40 CFR 144.7 - Identification of underground sources of drinking water and exempted aquifers.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 23 2014-07-01 2014-07-01 false Identification of underground sources of drinking water and exempted aquifers. 144.7 Section 144.7 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) UNDERGROUND INJECTION CONTROL PROGRAM General Provisions § 144.7 Identification of...

  8. 40 CFR 144.12 - Prohibition of movement of fluid into underground sources of drinking water.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... other injection activity in a manner that allows the movement of fluid containing any contaminant into underground sources of drinking water, if the presence of that contaminant may cause a violation of any... source of drinking water indicates the movement of any contaminant into the underground source of...

  9. Application of Paste Backfill in Underground Coal Fires

    NASA Astrophysics Data System (ADS)

    Masniyom, M.; Drebenstedt, C.

    2009-04-01

    Coal fires are known from different coalfields worldwide. China, India, USA, Australia, Indonesia and South Africa are the main countries affected by coal fires. The fires is thermally intensive and cause numerous sinkholes, large-scale subsidence, air pollution, global warming, loss of mining productivity and increasing safety risk. The Wuda Inner Mongolia coalfield has been selected as a possible test area for paste backfill. The traditional methods, executed by fire fighting teams, by covering the coalfire areas with soil, blasting burning coal outcrops and injecting water in the subsurface fire pockets are continuously improved and extended. Initiatives to introduce modern techniques, such as backfill placement at fracture and borehole, to cool down the burning coal and cut off the air supply. This study is to investigate backfill materials and techniques suited for underground coal fires. Laboratory tests were carried out on physical, chemical and mechanical properties of different backfill materials and mixtures thereof. Special attention was paid to materials generated as by-products and other cheaply available materials e.g. fly ash from power plants. There is a good chance that one of the different material mixtures investigated can be used as a technically and economically viable backfill for underground coal fires.

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bollinger, J.M.; Kaplan, N.; Wilkening, H.A. Jr.

    Under contract from the Department of Energy, AAI Corporation designed, constructed, and operated a solar heating system to provide hot water for curing concrete blocks at the York Building Products Co., Inc.'s new manufacturing facility near Harrisburg, PA. The objective of Phase III of this program was to operate, collect data, and evaluate the solar system for a three-year period (September 1978 to September 1981). The solar facility utilizes 35 collectors with a total aperture area of 8960 ft/sup 2/. The sysem is designed to deliver a water/ethylene glycol solution at 200/sup 0/F to a heat exchanger, which, in turn,more » supplies water at 180/sup 0/F to a rotoclave (underground tank) for the concrete-block curing process. A fossil-fuel boiler system also supplies the rotoclave with processed hot water to supplement the solar system. The system was operational 92.5% of the days during which the data acquisition system was functional. Sufficient solar heating was available to deliver hot water to the heat exchanger on 448 days, or 81.8% of the days on which reliable data was recorded. Total fuel saved during the three-year period was 10,284 gallons. Thus, this program has successfully demonstrated the technical feasibility of generating industrial process hot water with solar energy.« less

  11. Concentrations and identification of culturable airborne fungi in underground stations of the Seoul metro.

    PubMed

    Hwang, Sung Ho; Jang, Soojin; Park, Wha Me; Park, Jae Bum

    2016-10-01

    The purpose of this study was to measure the culturable airborne fungi (CAF) concentrations in the underground subway stations of Seoul, Korea at two time points. This study measured the CAF concentrations in enclosed environments at 16 underground stations of the Seoul Metro in 2006 and 2013 and investigated the effects of various environmental factors, including the presence of platform screen doors, temperature, relative humidity, and number of passengers. CAF concentrations at the stations in 2006 were significantly higher than that at the same stations in 2013 (p < 0.001). Furthermore, there was a significant correlation between CAF concentration and relative humidity (r = 0.311, p < 0.05). Geotrichum and Penicillium were the predominant genera. The CAF concentrations in stations with an operating supply air were significantly higher than that in stations with no supply air (p < 0.001). Therefore, it is recommended that special attention be given to stations with clean supplied air to improve the indoor air quality of these subway stations.

  12. A waterborne outbreak of multiple diarrhoeagenic Escherichia coli infections associated with drinking water at a school camp.

    PubMed

    Park, Jungsun; Kim, Jin Seok; Kim, Soojin; Shin, Eunkyung; Oh, Kyung-Hwan; Kim, Yonghoon; Kim, Cheon Hyeon; Hwang, Min Ah; Jin, Chan Mun; Na, Kyoungin; Lee, Jin; Cho, Enhi; Kang, Byung-Hak; Kwak, Hyo-Sun; Seong, Won Keun; Kim, Junyoung

    2018-01-01

    In June 2015, a local public health laboratory was notified that students had developed gastroenteritis symptoms after attending a camp. An outbreak investigation was conducted to determine the extent and cause of the outbreak. A retrospective cohort study was conducted to determine the correlations between the illness and specific exposures at the school camp. All attendees were interviewed with a standard questionnaire that addressed clinical symptoms, food consumption, and environmental exposures. Clinical specimens were cultured using standard microbiological methods for bacterial and viral pathogens. The genetic relationships of all isolates were determined using pulsed-field gel electrophoresis (PFGE). A total 188 patients with symptoms of diarrhoea, abdominal pain, and nausea were identified. The completed questionnaires suggested that the consumption of drinking water was likely to be linked to this outbreak. Using microbiological methods, enterohaemorrhagic Escherichia coli, enteropathogenic E. coli, and enteroaggregative E. coli were isolated, and the isolates from both patient stool and environmental water samples displayed indistinguishable XbaI-PFGE patterns. The water system in the camp used groundwater drawn from a private underground reservoir for cooking and drinking. The environmental investigation revealed some problems with the water supply system, such as the use of inappropriate filters in the water purifier and a defect in the pipeline between the reservoir and the chlorination device. This outbreak points to the importance of drinking water quality management in group facilities where underground water is used and emphasizes the need for periodic sanitation and inspection to prevent possible waterborne outbreaks. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  13. Organic Carbon as Inhibitor to SVOC and Metal Migration

    EPA Science Inventory

    The Safe Drinking Water Act (SDWA) authorizes the Underground Injection Control (UIC) program to protect underground drinking water (USDW) sources from contamination caused by underground injection wells, including regulation of stormwater drainage drywells for parking lot and ro...

  14. Preliminary Toxicological Analysis of the Effect of Coal Slurry Impoundment Water on Human Liver Cells

    USGS Publications Warehouse

    Bunnell, Joseph E.

    2008-01-01

    Coal is usually 'washed' with water and a variety of chemicals to reduce its content of sulfur and mineral matter. The 'washings' or 'coal slurry' derived from this process is a viscous black liquid containing fine particles of coal, mineral matter, and other dissolved and particulate substances. Coal slurry may be stored in impoundments or in abandoned underground mines. Human health and environmental effects potentially resulting from leakage of chemical substances from coal slurry into drinking water supplies or aquatic ecosystems have not been systematically examined. Impoundments are semipermeable, presenting the possibility that inorganic and organic substances, some of which may be toxic, may contaminate ground or surface water. The Agency for Toxic Substances and Disease Registry, part of the Centers for Disease Control and Prevention, has concluded that well water in Mingo County, West Virginia, constitutes a public health hazard.

  15. Development of a model to determine oxygen consumption when crawling

    PubMed Central

    Pollard, J.P.; Heberger, J.R.; Dempsey, P.G.

    2016-01-01

    During a mine disaster or emergency, underground air can quickly become contaminated. In these circumstances, all underground mine workers are taught to don breathable air supply units at the first sign of an emergency. However, no contemporary oxygen consumption data is available for the purposes of designing breathing air supply equipment specifically for mine escape. Further, it would be useful to quantify the oxygen requirements of breathing air supply users for various escape scenarios. To address this need, 14 participants crawled a distance of 305 m each while their breath-by-breath oxygen consumption measurements were taken. Using these data, linear regression models were developed to determine peak and average oxygen consumption rates as well as total oxygen consumption. These models can be used by manufacturers of breathing air supply equipment to aid in the design of devices that would be capable of producing sufficient on-demand oxygen to allow miners to perform self-escape. PMID:26997858

  16. Geohydrology and potential hydrologic effects of underground coal mining in the Rapid Creek Basin, Mesa County, Colorado

    USGS Publications Warehouse

    Brooks, Tom

    1986-01-01

    The U.S. Bureau of Land Management may lease additional coal tracts in the Rapid Creek basin, Colorado. Springs in this basin are used as a water supply for the town of Palisade. The geohydrology of the basin is described and the potential hydrologic effects of underground coal mining in the basin summarized. Geologic formations in the basin consists of Cretaceous sandstone and shale, Tertiary sandstone, shale, and basalt, and unconsolidated deposits of Quaternary age. Some sandstone and coal beds are permeable, although bedrock in the basin typically is a confining bed. Unconsolidated deposits contain aquifers that are the source of spring discharge. Stream discharge was measured on Rapid and Cottonwood Creeks, and inventories were made of 7 reservoirs, 25 springs, and 12 wells. Specific conductance of streams ranged from 320 to 1,050 microsiemens/cm at 25C; pH ranged from 7.8 to 8.6. Specific conductance of springs ranged from 95 to 1,050 microsiemens/cm at 25C; pH ranged from 6.8 to 8.3. Discharge from the basin includes about 18,800 acre-ft/yr as evapotranspiration, 1,300 acre-ft/yr as springflow, 1,280 acre-ft/yr as streamflow, and negligible groundwater flow in bedrock. With appropriate mining methods, underground mining would not decrease flow in basin streams or from springs. The potential effects of mining-caused subsidence might include water-pipeline damage and temporary dewatering of bedrock adjacent to coal mining. (Author 's abstract)

  17. Hydrogeology, groundwater flow, and groundwater quality of an abandoned underground coal-mine aquifer, Elkhorn Area, West Virginia

    USGS Publications Warehouse

    Kozar, Mark D.; McCoy, Kurt J.; Britton, James Q.; Blake, B.M.

    2017-01-01

    The Pocahontas No. 3 coal seam in southern West Virginia has been extensively mined by underground methods since the 1880’s. An extensive network of abandoned mine entries in the Pocahontas No. 3 has since filled with good-quality water, which is pumped from wells or springs discharging from mine portals (adits), and used as a source of water for public supplies. This report presents results of a three-year investigation of the geology, hydrology, geochemistry, and groundwater flow processes within abandoned underground coal mines used as a source of water for public supply in the Elkhorn area, McDowell County, West Virginia. This study focused on large (> 500 gallon per minute) discharges from the abandoned mines used as public supplies near Elkhorn, West Virginia. Median recharge calculated from base-flow recession of streamflow at Johns Knob Branch and 12 other streamflow gaging stations in McDowell County was 9.1 inches per year. Using drainage area versus mean streamflow relationships from mined and unmined watersheds in McDowell County, the subsurface area along dip of the Pocahontas No. 3 coal-mine aquifer contributing flow to the Turkey Gap mine discharge was determined to be 7.62 square miles (mi2), almost 10 times larger than the 0.81 mi2 surface watershed. Results of this investigation indicate that groundwater flows down dip beneath surface drainage divides from areas up to six miles east in the adjacent Bluestone River watershed. A conceptual model was developed that consisted of a stacked sequence of perched aquifers, controlled by stress-relief and subsidence fractures, overlying a highly permeable abandoned underground coal-mine aquifer, capable of substantial interbasin transfer of water. Groundwater-flow directions are controlled by the dip of the Pocahontas No. 3 coal seam, the geometry of abandoned mine workings, and location of unmined barriers within that seam, rather than surface topography. Seven boreholes were drilled to intersect abandoned mine workings in the Pocahontas No. 3 coal seam and underlying strata in various structural settings of the Turkey Gap and adjacent down-dip mines. Geophysical logging and aquifer testing were conducted on the boreholes to locate the coal- mine aquifers, characterize fracture geometry, and define permeable zones within strata overlying and underlying the Pocahontas No. 3 coal-mine aquifer. Water levels were measured monthly in the wells and showed a relatively static phreatic zone within subsided strata a few feet above the top of or within the Pocahontas No. 3 coal-mine aquifer (PC3MA). A groundwater-flow model was developed to verify and refine the conceptual understanding of groundwater flow and to develop groundwater budgets for the study area. The model consisted of four layers to represent overburden strata, the Pocahontas No. 3 coal-mine aquifer, underlying fractured rock, and fractured rock below regional drainage. Simulation of flow in the flooded abandoned mine entries using highly conductive layers or zones within the model, was unable to realistically simulate interbasin transfer of water. Therefore it was necessary to represent the coal-mine aquifer as an internal boundary condition rather than a contrast in aquifer properties. By representing the coal-mine aquifer with a series of drain nodes and optimizing input parameters with parameter estimation software, model errors were reduced dramatically and discharges for Elkhorn Creek, Johns Knob Branch, and other tributaries were more accurately simulated. Flow in the Elkhorn Creek and Johns Knob Branch watersheds is dependent on interbasin transfer of water, primarily from up dip areas of abandoned mine workings in the Pocahontas No. 3 coal-mine aquifer within the Bluestone River watershed to the east. For the 38th, 70th, and 87th percentile flow duration of streams in the region, mean measured groundwater discharge was estimated to be 1.30, 0.47, and 0.39 cubic feet per square mile (ft3/s/mi2

  18. A review on anthropogenic impact to the Micro Prespa lake and its damages

    NASA Astrophysics Data System (ADS)

    Frasheri, N.; Pano, N.; Frasheri, A.; Beqiraj, G.; Bushati, S.; Taska, E.

    2012-04-01

    Paper presents the results of the integrated and multidisciplinary studies for investigation of the anthropogenic damages to Albanian part of the transborder Micro Prespa Lake. Remote sensing with Landsat images was used for identification of environmental changes in time for the period 1970 - 2010. Micro Prespa Lake is lake with international status, as Ramsar Convection, International Park and Special Protection Area-79/409/EEC. According to the studies, investigations and analyses, the following were concluded: Devolli River- Micro Prespa Lake irrigation system was not scientifically supported by environmental engineering, hydroeconomy and International Rights principles. It does work according to the projected parameters, and also, doesn't supply the agricultural needs. About of 10 % of the water volume, discharges by Devolli River in Micro Prespa Lake during the winter, is taken from this lake for the irrigation in summer. Great surface of Albanian part of Micro Prespa Lake is destroyed. The other part of the lake is atrophied and the habitat and biodiversity are damaged. Important and unique species of fish, birds and plants of national and international values are risked. The underground karstic connection ways for water circulation are blocked. There are ruining the historic values of the area, such the encient Treni cave from the Bronze Age. The Albanian part of the Micro Prespa Lake has been damaged by the human activities. A huge amount of 1,2 million cubic meters alluvium has been deposited on the lake bottom and lakeshore, which was transported by the Devolli River waters, since 1974. This river waters, rich in alluvium and organic coal material from outcropped geological formations, also absorbed free chemical toxic remains by the drainage of Devolli farm ground, which have changed the chemical features of the lake water and degrading it. Micro Prespa Lake communicates with Macro Prespa Lake, and together with Ohrid Lake. Blockage of underground karstic connection ways has diminished not only the components of the lake water balance, but also the decreasing yield of the underground springs, that supply the Ohrid lake and drinkable water springs. The Albanian part of the Micro Prespa Lake plays the role of a gigantic decanter. This is an unprecedented case, not only in Albanian but also in Balkan and World hydrography. Devolli river alluvium deposited in Micro Prespa Lake caused the otherwise of territory of Republic of Albania in this area. Albania will not have any part in this lake after some years. The social and public opinion in Albania, must be conscious for the otherwise of Albanian territory, which in the case of Micro Prespa Lake has a national and international negative effect on destructions of a transborder lake, defendey by Europian Convents.

  19. 40 CFR 144.82 - What must I do to protect underground sources of drinking water?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 23 2014-07-01 2014-07-01 false What must I do to protect underground sources of drinking water? 144.82 Section 144.82 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) UNDERGROUND INJECTION CONTROL PROGRAM Requirements for Owners and Operators of Class V Injection Wells...

  20. Ground-water resources of Atascosa County, Texas

    USGS Publications Warehouse

    Sundstrom, Raymond W.; Follett, C.R.

    1950-01-01

    Atascosa County, Tex., is underlain by water-bearing sands of Tertiary age that furnish water for domestic and stock supplies throughout the county, for the public supply of all except one of the towns and cities in the county, for irrigation in several localities, for drilling oil wells in the central and southern parts of the county, for washing glass sand in the northern part of the county, and for maintaining several lakes that are used for hunting and fishing. By far the most productive formation is the Carrizo sand, but supplies of considerable magnitude are also obtained from sands in the Mount Selman and Cook Mountain. formations. The rate of withdrawal from the Carrizo sand amounted to about 15,500 acre-feet a year in 1944-45 or an average of about 13.8 million gallons a day. This was about 6,000 acre-feet a year greater in 1944-45 than it was in 1929-30. Of the total amount of water withdrawn in 1944-45 about 6,500 acre-feet a year is largely wasted from uncontrolled flowing wells. If the waste of water from wells in the Carrizo sand were stopped, the consumption of water for useful purposes could be increased about 70 percent without increasing the draft on the underground reservoir. The increase in total withdrawals from the Carrizo sand has been accompanied by a general decline in the artesian head between 1929-30 and 1944 ranging from 3 to 25 feet. On the whole, the evidence shows that the artesian reservoir is not being overdrawn and that it will sustain a somewhat greater draft.

  1. Organic Carbon as Inhibitor to SVOC and Metal Migration in Stormwater Drywells Discharging to the Subsurface-SLIDES

    EPA Science Inventory

    The Safe Drinking Water Act (SDWA) authorizes the Underground Injection Control (UIC) program to protect underground drinking water (USDW) sources from contamination caused by underground injection wells, including regulation of stormwater drainage drywells for parking lot and ro...

  2. [Contamination and ecological risk assessment of polycyclic aromatic hydrocarbons in water and in Karst underground river catchment].

    PubMed

    Lan, Jia-Cheng; Sun, Yu-Chuan; Tian, Ping; Lu, Bing-Qing; Shi, Yang; Xu, Xin; Liang Zuo-Bing; Yang, Ping-Heng

    2014-10-01

    Water samples in Laolongdong underground river catchment were collected to determine the concentration, compositional profiles, and evaluate ecological risk of 16 priority polycyclic aromatic hydrocarbons (PAHs). PAHs were measured by GC/MS. The total concentrations of 16 PAH ranged from 81.5-8019 ng · L(-1) in underground river, 288.7-15,200 ng · L(-1) in karst springs, and 128.4-2,442 ng · L(-1) in surface water. Affected by waste water from Huangjueya town, concentrations of PAHs in underground river were higher than those in surface water and waste water from sinkhole. The PAHs profiles were dominated by 3 ring PAHs. There were differences of monthly variations of PAHs contents in the water, due to waste water, season and different characteristics of PAH. Surface water and waste water from sinkhole played an important role on contamination in the river. The levels of ecological risk were generally moderately polluted and heavily polluted according to all detected PAH compounds in the water.

  3. In Situ Corrosion and Heat Loss Assessment of Two Nonstandard Underground Heat Distribution System Piping Designs: Supplement-Appendices for Final Report on Project F07-AR01

    DTIC Science & Technology

    2011-06-01

    negative mission impacts . This report documents the assessment of two similar nonstandard UHDS piping system designs — one at Fort Carson, CO, and one at...psig and monitored for 2 hours to determine whether the conduit piping system is protected from ground water infiltration and its degrading impacts ...Conduits to/from this pit were tested from adjacent pits. 2. Supply, Return drains tested on 8/15/07: All Dry N S EW MH-3N ERDC/CERL TR-11-14 H13

  4. 2012 Groundwater Monitoring and Inspection Report Gnome-Coach, New Mexico, Site

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2013-03-01

    Gnome-Coach was the site of a 3-kiloton underground nuclear test conducted in 1961. Surface and subsurface contamination resulted from the underground nuclear testing, post-test drilling, and a groundwater tracer test performed at the site. Surface reclamation and remediation began after the underground testing. A Completion Report was prepared, and the State of New Mexico is currently proceeding with a conditional certificate of completion for the surface. Subsurface corrective action activities began in 1972 and have generally consisted of annual sampling and monitoring of wells near the site. In 2008, the annual site inspections were refined to include hydraulic head monitoringmore » and collection of samples from groundwater monitoring wells onsite using the low-flow sampling method. These activities were conducted during this monitoring period on January 18, 2012. Analytical results from this sampling event indicate that concentrations of tritium, strontium-90, and cesium-137 were generally consistent with concentrations from historical sampling events. The exceptions are the decreases in concentrations of strontium-90 in samples from wells USGS-4 and USGS-8, which were more than 2.5 times lower than last year's results. Well USGS-1 provides water for livestock belonging to area ranchers, and a dedicated submersible pump cycles on and off to maintain a constant volume in a nearby water tank. Water levels in wells USGS-4 and USGS-8 respond to the on/off cycling of the water supply pumping from well USGS-1. Well LRL-7 was not sampled in January, and water levels were still increasing when the transducer data were downloaded in September. A seismic reflection survey was also conducted this year. The survey acquired approximately 13.9 miles of seismic reflection data along 7 profiles on and near the site. These activities were conducted from February 23 through March 10, 2012. The site roads, monitoring well heads, and the monument at surface ground zero were in good condition at the time of the site inspection. However, it was reported in September 2012 that the USGS-1 well head had been damaged by a water truck in April 2012.« less

  5. Rehabitilation and extension of a khettara for a sustainable use of underground water resources

    NASA Astrophysics Data System (ADS)

    Pilia, A.; Spanu, V.; Concollato, C.; Calzolai, E.; Valenilla, A. M.

    2009-04-01

    As one of the major effects of soil degradation resulting from antropogenic factors and influenced by climate variations, desertification represents a significant environmental issue in arid and semi-arid areas. Owing to a lack of resources to tackle the problem, the consequences of desertification drastically affect the population of developing countries. One of the areas affected by this problem is the desert area of Hassi Labiad, near to Merzouga, in the South- East of Morocco, close to the border with Algeria, where the Erg Chebbi desert begins. From a geological point of view the studied zone extends across coarse sand dunes from Quaternary (Erg Chebbi Desert), which lies on a basement constituted by clay schist with sandstone intercalations and mauve- grayish sandstone from Lower Viséen (Carboniferous). Basement outcrops are identified in the area. In this area, the hydrological supply has been guaranteed for thousands of years by an ancient irrigation system, used in these area since about 1000 BC, the so called khettara. This system, from its creation by the Persians, has been diffused across the whole arabic culture; it's based on the picking up of water through underground draining channels from shallow acquifers with an altitude above sea level, which are higher than the irrigation areas to which water is brought. This system worked until a few years ago when, due to touristic development in the area, many groundwater pumping wells were created; the overpumping caused the decrease of groundwater level. Therefore, there was no more intersection between the khettara channel and the aquifer; and it became necessary to find a new intersection point by prolongating the ketthara principal channel. This project has been promoted and directed by the UNDP, the local ONG AHT Hassi Labiad in collaboration with Bambini nel Deserto NGO, and Osservatorio Mediterraneo Onlus. Basically, it consisted of a hydrogeological study in order to check the feasibility of the extension and the optimal peculiarities for the new channelling, for a sustainable use of underground water resources. The methodology consisted principally of topographic and water level measurements through wells and piezometers. Most of these measurements were made in water wells that already exist, due to the existence of the old khettara, while in the areas where enough density of measurement points is not found, new piezometres have been realised. Moreover, an analysis of rain gauge data and a valuation of the quantity of the underground water taken from the system have been carried out, in order to make a first hydrogeological balance. From the achieved results with the hydrogeological study an extension of the khettara of 230 m with a E-W direction has been made, that allowed to reintercept the alluvial ground water and to create a drainage system able to pick up the underground water in a sustainable way, also during the driest period of the year. Work carried out with a Bambini nel Deserto project, with the financial support of UNDP, the local ONG AHT Hassi Labiad in collaboration with Osservatorio Mediterraneo Onlus.

  6. Tri-party underground symbiosis between a weevil, bacteria and a desert plant.

    PubMed

    Shelef, Oren; Helman, Yael; Friedman, Ariel-Leib-Leonid; Behar, Adi; Rachmilevitch, Shimon

    2013-01-01

    Inhabitants of arid ecosystems face severe nitrogen and water limitations. Inventive adaptations by organisms occupying such habitats are essential for survival. This study describes a tri-party symbiotic interaction between a plant (Salsola inermis), a beetle (Conorhynchus pistor), and a bacterium (Klebsiella pneumonia). The weevil survives by living within a mud structure affixed to the plant roots, thus benefiting from increased carbon and water, and refuge from predators and parasites. Active nitrogen-fixing bacteria harbored within the weevil's gut mediate this interaction, by supplying nitrogen to the system, which eventually promotes seed development. We studied the correlation between the weevil's existence and (i) root carbon and nitrogen content, (ii) soil water content and (iii) seed weight. Roots hosting weevils contained more nitrogen, heavier seeds and less carbon. In addition, water content was higher around the roots than in open spaces a short distance from the plant stem. Bacterial studies and nitrogen-fixation analyses, including molecular and chemical assays, indicated atmospheric nitrogen fixation in the larval stage and identified the bacterium. The coexistence of weevil and bacterial behavior coinciding with the plant's life cycle was revealed here by a long period of field observations. Out of over 60,000 known weevils, this is the only report of a weevil living most of its life underground without harming plants. The unique tri-party interaction described herein shows the important ecological role of desert plant roots and provides an example of a sustainable consortium of living organisms coping with the challenging desert environment.

  7. Monitoring underground water leakage pattern by ground penetrating radar (GPR) using 800 MHz antenna frequency

    NASA Astrophysics Data System (ADS)

    Amran, T. S. T.; Ismail, M. P.; Ahmad, M. R.; Amin, M. S. M.; Ismail, M. A.; Sani, S.; Masenwat, N. A.; Basri, N. S. M.

    2018-01-01

    Water is the most treasure natural resources, however, a huge amount of water are lost during its distribution that leads to water leakage problem. The leaks meant the waste of money and created more economic loss to treat and fix the damaged pipe. Researchers and engineers have put tremendous attempts and effort, to solve the water leakage problem especially in water leakage of buried pipeline. An advanced technology of ground penetrating radar (GPR) has been established as one of the non-destructive testing (NDT) method to detect the underground water pipe leaking. This paper focuses on the ability of GPR in water utility field especially on detection of water leaks in the underground pipeline distribution. A series of laboratory experiments were carried out using 800-MHz antenna, where the performance of GPR on detecting underground pipeline and locating water leakage was investigated and validated. A prototype to recreate water-leaking system was constructed using a 4-inch PVC pipe. Different diameter of holes, i.e. ¼ inch, ½ inch, and ¾ inch, were drilled into the pipe to simulate the water leaking. The PVC pipe was buried at the depth of 60 cm into the test bed that was filled with dry sand. 15 litres of water was injected into the PVC pipe. The water leakage patterns in term of radargram data were gathered. The effectiveness of the GPR in locating the underground water leakage was ascertained, after the results were collected and verified.

  8. Protective and control relays as coal-mine power-supply ACS subsystem

    NASA Astrophysics Data System (ADS)

    Kostin, V. N.; Minakova, T. E.

    2017-10-01

    The paper presents instantaneous selective short-circuit protection for the cabling of the underground part of a coal mine and central control algorithms as a Coal-Mine Power-Supply ACS Subsystem. In order to improve the reliability of electricity supply and reduce the mining equipment down-time, a dual channel relay protection and central control system is proposed as a subsystem of the coal-mine power-supply automated control system (PS ACS).

  9. Method and apparatus for the in situ decontamination of underground water with the aid of solar energy

    DOEpatents

    Bench, Thomas R.; McCann, Larry D.

    1989-01-01

    A method for the in situ decontamination of underground water containing -volatile contaminants comprising continuously contacting in situ underground water containing non-volatile contaminants with a liquid-absorbent material possessing high capillary activity, allowing the non-volatile contaminants to deposit in the material while the water moves upwardly through the material by capillary action, allowing substantially decontaminated water to be volatilized by impinging solar radiation, and then allowing the volatilized water to escape from the material into the atmosphere. An apparatus for the in situ decontamination of underground water containing non-volatile contaminants comprising at least one water-impermeable elongated conduit having an upper portion and first and second open ends and containing a homogeneous liquid-absorbent material possessing high capillary activity, means for supporting said conduit, and means for accelerating the escape of the volatilized decontamined water from the material, said means being detachably connected to the second end of the elongated conduit; wherein when underground water contaminated with non-volatile contaminants is continuously contacted in situ with the material contained in the first end of the conduit and the second end of the conduit is placed in contact with atmospheric air, non-volatile contaminants deposit in said material as the water moves upwardly through the material by capillary action, is then volatilized by impinging solar energy and escapes to the atmosphere.

  10. Muon simulation codes MUSIC and MUSUN for underground physics

    NASA Astrophysics Data System (ADS)

    Kudryavtsev, V. A.

    2009-03-01

    The paper describes two Monte Carlo codes dedicated to muon simulations: MUSIC (MUon SImulation Code) and MUSUN (MUon Simulations UNderground). MUSIC is a package for muon transport through matter. It is particularly useful for propagating muons through large thickness of rock or water, for instance from the surface down to underground/underwater laboratory. MUSUN is designed to use the results of muon transport through rock/water to generate muons in or around underground laboratory taking into account their energy spectrum and angular distribution.

  11. Energy Harvesting from Fluid Flow in Water Pipelines for Smart Metering Applications

    NASA Astrophysics Data System (ADS)

    Hoffmann, D.; Willmann, A.; Göpfert, R.; Becker, P.; Folkmer, B.; Manoli, Y.

    2013-12-01

    In this paper a rotational, radial-flux energy harvester incorporating a three-phase generation principle is presented for converting energy from water flow in domestic water pipelines. The energy harvester together with a power management circuit and energy storage is used to power a smart metering system installed underground making it independent from external power supplies or depleting batteries. The design of the radial-flux energy harvester is adapted to the housing of a conventional mechanical water flow meter enabling the use of standard components such as housing and impeller. The energy harvester is able to generate up to 720 mW when using a flow rate of 20 l/min (fully opened water tab). A minimum flow rate of 3 l/min is required to get the harvester started. In this case a power output of 2 mW is achievable. By further design optimization of the mechanical structure including the impeller and magnetic circuit the threshold flow rate can be further reduced.

  12. Ground Water Discharges (EPA's Underground Injection ...

    EPA Pesticide Factsheets

    2017-07-06

    Most ground water used for drinking occurs near the earth's surface and is easily contaminated. Of major concern is the potential contamination of underground sources of drinking water by any of the hundreds of thousands of subsurface wastewater disposal injection wells nationwide.

  13. The rapid detection of methyl tert-butyl ether (MtBE) in water using a prototype gas sensor system.

    PubMed

    de Lacy Costello, B P J; Sivanand, P S; Ratcliffe, N M; Reynolds, D M

    2005-01-01

    The gasoline additive Methyl-tertiary-Butyl Ether (MtBE) is the second most common contaminant of groundwater in the USA and represents an important soil contaminant. This compound has been detected in the groundwater in at least 27 states as a result of leaking underground storage facilities (gasoline storage tanks and pipelines). Since the health effects of MtBE are unclear the potential threat to drinking water supplies is serious. Therefore, the ability to detect MtBE at low levels (ppb) and on-line at high-risk groundwater sites would be highly desirable. This paper reports the use of 'commercial' and metal oxide sensor arrays for the detection of MtBE in drinking and surface waters at low ppb level (microg.L(-1) range). The output responses from some of the sensors were found to correlate well with MtBE concentrations under laboratory conditions.

  14. Fog Collection Pilot Project (FCPP) in the Eastern Escarpments of Eritrea

    NASA Astrophysics Data System (ADS)

    Gherezghiher, T.

    2010-07-01

    Eritrea is water scarce country that relies heavily on underground water reserve and more than 80% of the rural population does not have access to safe and clean drinking water. In the rural areas, shallow hand dug wells are the primary sources of water and in most cases their discharge rate is deteriorating due to the recurrent drought. Particularly, in the targeted project areas underground water reserve is hard to find due to the steep topography. However, in these parts of Eritrea one will find a sector of mountains, about 700 km long, where the wind transports moist air from the Red Sea forming fog on the highlands. The area of the FCPP is the region of Maakel, near the villages Nefasit and Arborobu. The overall objective of his FCPP was to provide supplementary water supply system from large fog collectors (LFCs) in order to increase access to safe and clean drinking water in the targeted Schools and surrounding villages. Communities and students were organized to participate in the implementation of the project. Forty LFCs were established in all the targeted areas in previously evaluated potential locations. The project was implemented by Vision Eritrea, a National NGO in partnership with the country's' Water Resource Department; Fog Quest a Canadian NGO and Water Foundation, a German NGO, who also funded the project. The FCPP focused on introducing a new innovative water harvesting technology which is a crucial element for the survival of the people in the mountainous escarpment of the country; and with prospect of locally owned solutions for a sustainable management of and access to natural resource. Preliminary evaluation of the project showed that there was a good production of fog water, with an average of 6-8 litters/m2/day on the low intensity of fog and from 12 -18 litters on the high fog intensity. A functional water committee was established and trained on water management and maintenance of the LFC. They also developed water bylaw by which the water committee manages the water supply system. Similarly, the fog collectors have also been proved indeed to collect rain water during the wet seasons. This will extend the water harvesting period of the LFC within a year. The new fog harvest technology will further be developed in the target areas and in the long term is expected to help decrease poverty, improve food security and have a positive impact of the livelihood of target communities and neighboring villages. As a result, its dissemination and the mainstreaming of the action will be greatly facilitated to other similar part of the country where water can be harvested from fog.

  15. Incidence of multiple antibiotic resistant Gram-negative bacteria isolated from surface and underground water sources in south western region of Nigeria.

    PubMed

    Oluyege, J O; Dada, A C; Odeyemi, A T

    2009-01-01

    In most rural and urban settlements, particularly in Nigeria, wells, spring, streams or rivers and lakes serves as major sources of water supply for drinking and other domestic purposes. Unfortunately, many of the available water sources are not potable without some form of treatment which is seldom available in most settings. The use of untreated surface water sources for drinking and for domestic purposes remains a major threat to public health as these could serve as reservoirs the for transfer of antibiotic resistant pathogens. The incidence of resistant bacteria isolated from surface and underground water in six rural settlements in Ekiti State Nigeria was thus investigated. Gram-negative bacteria were isolated from wells, streams and boreholes in six rural settlements in Ekiti State Nigeria between January and April, 2006 and the prevalence of organisms exhibiting multiple antibiotic resistance to tetracycline, amoxicillin, cotrimoxazole, nitofurantoin, gentamicin, nalidixic acid and ofloxacin was observed. Gram-negative bacterial isolates comprised Escherichia coli (22.7%), Enterobacter aerogenes (2.5%), Salmonella spp. (13.3%), Shigella spp. (19.3%), Proteus spp. (18.5%), Klebsiella spp. (19.3%) and Pseudomonas aeruginosa (4.2%). Over 10% of the bacteria were resistant to four or more antibiotic. Antibiotic resistance was highest in members of the genera Enterobacter, Pseudomonas, and Proteus. Given the prevalence of appalling sanitary facilities and inappropriate public antibiotic use, the possibility of antibiotic resistance selection, faecal dissemination and subsequent contamination of local water sources available for rural residents of the developing world is highlighted. The implication for clinical practice of infections caused by antibiotic resistant strains especially among immunodeficient individuals is also discussed.

  16. 18 CFR 157.213 - Underground storage field facilities.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 18 Conservation of Power and Water Resources 1 2013-04-01 2013-04-01 false Underground storage... of the Natural Gas Act for Certain Transactions and Abandonment § 157.213 Underground storage field... operate facilities for the remediation and maintenance of an existing underground storage facility...

  17. 18 CFR 157.213 - Underground storage field facilities.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 18 Conservation of Power and Water Resources 1 2014-04-01 2014-04-01 false Underground storage... of the Natural Gas Act for Certain Transactions and Abandonment § 157.213 Underground storage field... operate facilities for the remediation and maintenance of an existing underground storage facility...

  18. History and hydrologic effects of ground water use in Kings, Queens, and western Nassau counties, Long Island, New York, 1800's through 1997

    USGS Publications Warehouse

    Cartwright, Richard A.

    2002-01-01

    Ground-water withdrawals from the aquifers underlying Kings and Queens Counties varied temporally and spatially during the 20th century and caused extreme changes in water levels. The resultant lowering of water levels during periods of heavy pumping caused saltwater intrusion in nearshore areas and the migration of contaminants from land surface into deep aquifers. The recovery of water levels in response to countywide curtailment of pumping has resulted in the flooding of underground structures. Combined withdrawals for public and industrial supply in Kings and Queens Counties were greatest during the 1930's--about 130 million gallons per day. During this period, a large cone of depression developed in the water table in Kings County; within this depression, water levels were about 45 feet lower than in 1903. All pumping for public supply was halted in Kings County in 1947, and in Jamaica (in Queens County) in 1974. Water levels in Kings County had recovered by 1974 and have remained similar to those of 1903 since then, except for minor localized drawdowns due to industrial-supply or dewatering withdrawals. A large cone of depression that had formed in southeastern Queens County before 1974 has now (1997) disappeared. The estimated combined withdrawal for public supply and industrial supply in Kings and Queens Counties in 1996 was only about 50 million gallons per day.The water-level recoveries in the water-table and confined aquifers generally have resulted in the dilution and dispersion of residual salty and nitrate-contaminated ground water. The majority of recently sampled wells indicate stable or decreasing chloride and nitrate concentrations in all aquifers since 1983. Organic contaminants remain in ground water in Kings, Queens, and Nassau Counties, however; the most commonly detected compounds in 1992-96 were tetrachloroethene, trichloroethene, chloroform, and total trihalomethanes. Water samples from monitoring wells in Kings County indicate a greater number of occurrences of these compounds in the upper glacial aquifer than in the Jameco-Magothy aquifer, whereas samples from public-supply wells in Queens County indicated a greater number of occurrences in the Jameco- Magothy aquifer than in the upper glacial aquifer. This distribution suggests that organic contaminants were not drawn into the deeper aquifers in Kings County before 1947, when their use was limited and deep withdrawals were greatest, and (or) that the longer period of waterlevel recovery in Kings County than in Queens has allowed greater degradation, dilution, and dispersion of any organic contaminants that might have entered the deep aquifers before the cessation of pumping in 1947.

  19. 40 CFR 35.680 - Purpose.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... ASSISTANCE Environmental Program Grants for Tribes Underground Water Source Protection (section 1443(b)) § 35.680 Purpose. (a) Purpose of section. Sections 35.680 through 35.688 govern underground water source protection grants to Tribes and Intertribal Consortia under section 1443(b) of the Safe Drinking Water Act...

  20. 40 CFR 35.190 - Purpose.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... ASSISTANCE Environmental Program Grants Underground Water Source Protection (section 1443(b)) § 35.190 Purpose. (a) Purpose of section. Sections 35.190 through 35.198 govern Underground Water Source Protection Grants to States (as defined in section 1401(13)(A) of the Safe Drinking Water Act) authorized under...

  1. 40 CFR 35.190 - Purpose.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... ASSISTANCE Environmental Program Grants Underground Water Source Protection (section 1443(b)) § 35.190 Purpose. (a) Purpose of section. Sections 35.190 through 35.198 govern Underground Water Source Protection Grants to States (as defined in section 1401(13)(A) of the Safe Drinking Water Act) authorized under...

  2. 40 CFR 35.680 - Purpose.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... ASSISTANCE Environmental Program Grants for Tribes Underground Water Source Protection (section 1443(b)) § 35.680 Purpose. (a) Purpose of section. Sections 35.680 through 35.688 govern underground water source protection grants to Tribes and Intertribal Consortia under section 1443(b) of the Safe Drinking Water Act...

  3. 40 CFR 144.82 - What must I do to protect underground sources of drinking water?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 24 2012-07-01 2012-07-01 false What must I do to protect underground... Operators of Class V Injection Wells Requirements for All Class V Injection Wells § 144.82 What must I do to protect underground sources of drinking water? If you own or operate any type of Class V well, the...

  4. 40 CFR 144.82 - What must I do to protect underground sources of drinking water?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 23 2011-07-01 2011-07-01 false What must I do to protect underground... Operators of Class V Injection Wells Requirements for All Class V Injection Wells § 144.82 What must I do to protect underground sources of drinking water? If you own or operate any type of Class V well, the...

  5. 40 CFR 144.82 - What must I do to protect underground sources of drinking water?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 24 2013-07-01 2013-07-01 false What must I do to protect underground... Operators of Class V Injection Wells Requirements for All Class V Injection Wells § 144.82 What must I do to protect underground sources of drinking water? If you own or operate any type of Class V well, the...

  6. 43 CFR 3484.1 - Performance standards for exploration and surface and underground mining.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... officer. Operators/lessees of underground coal mines shall adopt measures consistent with known technology... subsequent operations on the quantity, quality, or pressure of ground water or mine gases only with the... mines—(1) Underground resource recovery. Underground mining operations shall be conducted so as to...

  7. 43 CFR 3484.1 - Performance standards for exploration and surface and underground mining.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... officer. Operators/lessees of underground coal mines shall adopt measures consistent with known technology... subsequent operations on the quantity, quality, or pressure of ground water or mine gases only with the... mines—(1) Underground resource recovery. Underground mining operations shall be conducted so as to...

  8. 76 FR 51970 - Agency Information Collection Activities; Proposed Collection; Comment Request; Underground...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-19

    ... recordkeeping burden for this collection of information is estimated to average 2.32 hours per response. Burden... . FOR FURTHER INFORMATION CONTACT: Robert E. Smith, Office of Ground Water and Drinking Water/Drinking Water Protection Division/Underground Injection Control Program, Mailcode: 4606M, Environmental...

  9. 77 FR 9847 - Safety Zone; Kinnickinnic River Containment and Cleanup; Milwaukee, WI

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-21

    ... entering the Kinnickinnic River from an underground fuel leak in the vicinity of the airport in Milwaukee... That Significantly Affect Energy Supply, Distribution, or Use. We have determined that it is not a... Executive Order 12866 and is not likely to have a significant adverse effect on the supply, distribution, or...

  10. [Multi-Scale Convergence of Cold-Land Process Representation in Land-Surface Models, Microwave Remote Sensing, and Field Observations

    NASA Technical Reports Server (NTRS)

    Shi, Jiancheng

    2005-01-01

    The cryosphere is a major component of the hydrosphere and interacts significantly with the global climate system, the geosphere, and the biosphere. Measurement of the amount of water stored in the snow pack and forecasting the rate of melt are thus essential for managing water supply and flood control systems. Snow hydrologists are confronted with the dual problems of estimating both the quantity of water held by seasonal snow packs and time of snow melt. Monitoring these snow parameters is essential for one of the objectives of the Earth Science Enterprise-understanding of the global hydrologic cycle. Measuring spatially distributed snow properties, such as snow water equivalence (SWE) and wetness, from space is a key component for improvement of our understanding of coupled atmosphere-surface processes. Through the GWEC project, we have significantly advanced our understandings and improved modeling capabilities of the microwave signatures in response to snow and underground properties.

  11. Tri-Party Underground Symbiosis between a Weevil, Bacteria and a Desert Plant

    PubMed Central

    Shelef, Oren; Helman, Yael; Friedman, Ariel-Leib-Leonid; Behar, Adi; Rachmilevitch, Shimon

    2013-01-01

    Inhabitants of arid ecosystems face severe nitrogen and water limitations. Inventive adaptations by organisms occupying such habitats are essential for survival. This study describes a tri-party symbiotic interaction between a plant (Salsola inermis), a beetle (Conorhynchus pistor), and a bacterium (Klebsiella pneumonia). The weevil survives by living within a mud structure affixed to the plant roots, thus benefiting from increased carbon and water, and refuge from predators and parasites. Active nitrogen-fixing bacteria harbored within the weevil's gut mediate this interaction, by supplying nitrogen to the system, which eventually promotes seed development. We studied the correlation between the weevil's existence and (i) root carbon and nitrogen content, (ii) soil water content and (iii) seed weight. Roots hosting weevils contained more nitrogen, heavier seeds and less carbon. In addition, water content was higher around the roots than in open spaces a short distance from the plant stem. Bacterial studies and nitrogen-fixation analyses, including molecular and chemical assays, indicated atmospheric nitrogen fixation in the larval stage and identified the bacterium. The coexistence of weevil and bacterial behavior coinciding with the plant's life cycle was revealed here by a long period of field observations. Out of over 60,000 known weevils, this is the only report of a weevil living most of its life underground without harming plants. The unique tri-party interaction described herein shows the important ecological role of desert plant roots and provides an example of a sustainable consortium of living organisms coping with the challenging desert environment. PMID:24244267

  12. Groundwater balance in the Khor Arbaat basin, Red Sea State, eastern Sudan

    NASA Astrophysics Data System (ADS)

    Elsheikh, Abdalla E. M.; Zeielabdein, Khalid A. Elsayed; Babikir, Ibrahim A. A.

    2009-12-01

    The Khor Arbaat basin is the main source of potable water supply for the more than 750,000 inhabitants of Port Sudan, eastern Sudan. The variation in hydraulic conductivity and storage capacity is due to the heterogeneity of the sediments, which range from clay and silt to gravely sand and boulders. The water table rises during the summer and winter rainy seasons; it reaches its lowest level in the dry season. The storage capacity of the Khor Arbaat aquifer is estimated to be 21.75 × 106 m3. The annual recharge through the infiltration of flood water is about 1.93 × 106 m3. The groundwater recharge, calculated as underground inflow at the ‘upper gate’, is 1.33 × 105 m3/year. The total annual groundwater recharge is 2.06 × 106 m3. The annual discharge through underground outflow at the ‘lower gate’ (through which groundwater flows onto the coastal plain) is 3.29 × 105 m3/year. Groundwater discharge due to pumping from Khor Arbaat basin is 4.38 × 106 m3/year on average. The total annual groundwater discharge is about 4.7 × 106 m3. A deficit of 2.6 × 106 m3/year is calculated. Although the total annual discharge is twice the estimated annual recharge, additional groundwater flow from the fractured basement probably balances the annual groundwater budget since no decline is observed in the piezometric levels.

  13. Underground Coal Preparation System and Applications

    NASA Astrophysics Data System (ADS)

    Wei, Cao; DeYong, Shang; BaoNing, Zhang

    2018-03-01

    The underground coal preparation is a cutting-edge technology of the coal industry worldwide. This paper introduced the meaning of implementing the underground coal preparation, and the practical applications of underground mechanical moving screen jig, underground heavy medium shallow slot and underground air jigger. Through analyzing the main separation equipment and the advantages and disadvantages of three primary processes from aspects of process complexity, slime water treatment, raw coal preparation, etc., the difference among technology investment, construction scale, production cost and economic benefit is concluded.

  14. Evaluating the Impacts of Urbanization on Hydrological Processes and Water Resources by Comparing Two Neighboring Basins

    NASA Astrophysics Data System (ADS)

    Shao, M.; Zhao, G.; Gao, H.

    2017-12-01

    Texas, the fastest growing state in the US, has seen significant land cover/land use change due to urbanization over the past decades. With most of the region being arid/semi-arid, water issues are unprecedentedly pressing. Among the 15 major river basins, two adjacent river basins located in south-central Texas—the San Antonio River Basin (SARB) and the Guadalupe River Basin (GRB)—form an ideal testbed for evaluating the impacts of urbanization on both hydrological processes and water resources. These two basins are similar in size and in climate pattern, but differ in terms of urbanization progress. In SARB, where the city of San Antonio is located, the impervious area has increased from 0.6% (1929) to 7.8% (2011). In contrast, there is little land cover change in the GRB. With regard to the underground components, both basins intersect with the Edward Aquifer (more than 15% of basin area in both cases). The Edward Aquifer acts as one of the major municipal water supplies for San Antonio, and as the water source for local agricultural uses (and for the surrounding habitat). This aquifer has the characteristic of being highly sensitive to changes in surface water conditions, like the descending trend of the underground water table due to over exploitation. In this study, a distributed hydrologic model—DHSVM (the Distributed Hydrology Soil Vegetation Model)—is used to compare the hydrologic characteristics (and their impacts on water resources) over the two basins. With a 200m spatial resolution, the model is calibrated and validated during the historical period over both basins. The objectives of the comparisons are two-fold: First, the urbanization effects on peak flows are evaluated for selected extreme rainfall events; Second, the Edward Aquifer recharge rate from surface water under flood and/or drought conditions within the two basins is analyzed. Furthermore, future urbanization scenarios are tested to provide information relevant to decision making.

  15. 40 CFR 146.7 - Corrective action.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) UNDERGROUND... the additional steps needed to prevent fluid movement into underground sources of drinking water, the...; (b) Nature of native fluids or by-products of injection; (c) Potentially affected population; (d...

  16. 40 CFR 146.7 - Corrective action.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) UNDERGROUND... the additional steps needed to prevent fluid movement into underground sources of drinking water, the...; (b) Nature of native fluids or by-products of injection; (c) Potentially affected population; (d...

  17. 40 CFR 146.7 - Corrective action.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) UNDERGROUND... the additional steps needed to prevent fluid movement into underground sources of drinking water, the...; (b) Nature of native fluids or by-products of injection; (c) Potentially affected population; (d...

  18. 40 CFR 146.7 - Corrective action.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) UNDERGROUND... the additional steps needed to prevent fluid movement into underground sources of drinking water, the...; (b) Nature of native fluids or by-products of injection; (c) Potentially affected population; (d...

  19. Hydrology of the Upper Capibaribe Basin, Pernambuco, Brazil - A reconnaissance in an Area of Crystalline Rocks

    USGS Publications Warehouse

    Chada Filho, Luiz Goncalves; Dias Pessoa, Mario; Sinclair, William C.

    1966-01-01

    The upper Capibaribe basin is the western three-fourths, approximately, of the valley of the river that empties into the Atlantic Ocean at Recife, the capital of the State of Pernambuco, Brazil. It is the part of the drainage basin that is within the Drought Polygon of northeast Brazil, and it totals about 5,400 square kilometers. It receives relatively abundant precipitation in terms of the annual average, yet is regarded as hot subhumid to semiarid because the precipitation is uneven from year to year and place to place. The dependable water supply, therefore, is small. The basin has water, which could be put to better use than at present, but the opportunities for augmenting the usable supply are not great. The streams are intermittent and therefore cannot be expected to fill surface reservoirs and to keep them filled. The ground-water reservoirs have small capacity--quickly filled and quickly drained. A rough estimate based on the records for 1964 suggests that, of 4,700 million cubic meters of precipitation in the upper Capibaribe basin, 2,700 million cubic meters (57 percent) left the basin as runoff and 2,000 million cubic meters {43 percent) went into underground storage or was evaporated or transpired. The bedrock of the upper Capibaribe basin is composed of granite, gneiss, schist, and other varieties of crystalline rocks, which have only insignificant primary permeability. They are permeable mainly where fractured. The principal fracture zones, fortunately, are in the valleys, where water accumulates and can feed into them, but the volume of fractured rock is small in relation to the basin as a whole. A well in a large water-filled fracture zone may yield up to 20,000 liters per hour, but the average well yields less than one-fourth this amount, and some wells yield none. The saprolite, or weathered rock, is many meters thick at some places especially in the eastern half of the upper Capibaribe basin. It contains water locally, but ordinarily will yield only small quantities to wells. The alluvium probably is the most productive aquifer in the basin, but is limited to narrow bands along the rivers that generally are no more than a few hundred meters wide and 5 meters thick. The alluvium contains variable amounts of silty sand capable of yielding small to moderate quantities of water to wells. Wells driven or dug into the alluvium could solve many small water problems. The chemical quality of the water in the upper Capibaribe basin ranges from good to bad and generally presents a major problem that cannot be solved solely by applying geological criteria. Mineralized water is widespread in the area, both in streams and underground, and .the choice of aquifers is small. All known aquifers contain, at one place or another, water that is mineralized, leaving no alternative for a natural supply of good-quality water. Although much of the available water is unsatisfactory for human consumption, it is generally acceptable for animals and therefore meets one of the principal water needs. Some of the ground water could be made potable by diluting it with rainwater, which could be collected during rainy seasons and temporarily stored in cisterns or reservoirs.

  20. [Investigation of nitrogen, phosphorus and microbial contamination in Laolongdong underground river system of Chongqing].

    PubMed

    Lan, Jia-Cheng; Yang, Ping-Heng; Ren, Kun; Chen, Xue-Bin; Xu, Xin; Hu, Ning

    2014-04-01

    With urbanization, groundwater in China has been widely polluted. Karst groundwater is important in southwest China, and would be difficult to recover once contaminated. NO3(-), PO4(3), NH4(+), total coliform, total E. coli and fecal coliform were chosen as indexes in the study of groundwater of Laolongdong Underground River System in Nanshan Mountain, Chongqing. After a few years of survey, the results showed that NO3(-), NH4(+) and PO4(3-) concentrations in the water were all above the nature value, especially NH4(+) and PO4(3-). The NO3(-) concentration of Guihuawan spring ranged from 19.78-68.55 mg x L(-1), in some months, above the recommended water quality guideline (50 mg x L(-1)) according to Standards for Drinking Water Quality set by World Health Organization. NH4(+) and PO4(3-) concentrations in Laolongdong underground river varied from 2.71-12.92 mg x L(-1) and 0.16-11.22 mg x L(-1). The NO3(-) concentration in Laolongdong underground river was lower than in karst spring; however, the concentrations of NH4(+) and PO4(3-) were higher than in the spring. It seemed that the NO3(-) concentration tended to decrease from 2008 to 2013 in the underground river caused by urbanization, reduction of farmland and reducing environment. However, waste water with a high PO4(3-) concentration led to an increasing trend in the PO4(3-) concentration in underground river. Microbial contamination was extremely serious, and even far exceeded class V of water quality standards of China. For example, the concentration of fecal coliform in the groundwater ranged from 3.4 x 10(4)-3.68 x 10(4) CFU x mL(-1). Because of the special hydrogeological structure, karst depressions, skylights and sinkholes can lead pollutants easily to the underground water. Agriculture activity, sewage from towns, enterprises and residential areas were the major sources of nitrogen, phosphorus and microbial contamination.

  1. Assessment of underground water potential zones using modern geomatics technologies in Jhansi district, Uttar Pradesh, India.

    NASA Astrophysics Data System (ADS)

    Pandey, N. K.; Shukla, A. K.; Shukla, S.; Pandey, M.

    2014-11-01

    Ground water is a distinguished component of the hydrologic cycle. Surface water storage and ground water withdrawal are traditional engineering approaches which will continue to be followed in the future. The uncertainty about the occurrence, distribution and quality aspect of the ground water and the energy requirement for its withdrawal impose restriction on exploitation of ground water. The main objective of the study is assessment of underground water potential zones of Jhansi city and surrounding area, by preparing underground water potential zone map using Geographical Information System (GIS), remote sensing, and validation by underground water inventory mapping using GPS field survey done along the parts of National Highway 25 and 26 and some state highway passing through the study area. Study area covers an area of 1401 km2 and its perimeter is approximate 425 km. For this study Landsat TM (0.76-0.90 um) band data were acquired from GLCF website. Sensor spatial resolution is 30 m. Satellite image has become a standard tool aiding in the study of underground water. Extraction of different thematic layers like Land Use Land Cover (LULC), settlement, etc. can be done through unsupervised classification. The modern geometics technologies viz. remote sensing and GIS are used to produce the map that classifies the groundwater potential zone to a number of qualitative zone such as very high, high, moderate, low or very low. Thematic maps are prepared by visual interpretation of Survey of India topo-sheets and linearly enhanced Landsat TM satellite image on 1 : 50,000 scale using AutoCAD, ArcGIS 10.1 and ERDAS 11 software packages.

  2. Mars surface based factory. Phase 2, task 1C: Computer control of a water treatment system to support a space colony on Mars

    NASA Technical Reports Server (NTRS)

    Fuller, John; Ali, Warsame; Willis, Danette

    1989-01-01

    In a continued effort to design a surface based factory on Mars for the production of oxygen and water, a preliminary study was made of the surface and atmospheric composition on Mars and determined the mass densities of the various gases in the Martian atmosphere. Based on the initial studies, oxygen and water were determined to be the two products that could be produced economically under the Martian conditions. Studies were also made on present production techniques to obtain water and oxygen. Analyses were made to evaluate the current methods of production that were adaptable to the Martian conditions. Even though the initial effort was the production of oxygen and water, it was found necessary to produce some diluted gases that can be mixed with the oxygen produced to constitute 'breathable' air. The conceptual design of a breathable air manufacturing system, a means of drilling for underground water, and storage of water for future use were completed. The design objective was the conceptual design of an integrated system for the supply of quality water for biological consumption, farming, residential and industrial use.

  3. Visualization of hydraulic connections using Borehole Array around LPG Underground Storage Cavern

    NASA Astrophysics Data System (ADS)

    Shimo, M.; Mashimo, H.; Maejima, T.; Aoki, K.

    2006-12-01

    This paper presents a systematic approach to visualize the hydraulic connections within the fractured rock mass around the underground LPG storage caverns using array of water injection boreholes. By taking advantage that water injection boreholes are located so as to cover the storage caverns, a complete sketch of hydraulic conditions around the caverns, such as locations of water conducting fractures, hydraulic conductivity and groundwater pressure can be obtained. Applicability of the proposed techniques have been tested in an on-going construction project operated by JOGMEC, Japan Oil, Gas and Metals National Corporation, at Namikata, Western part of Japan. Three 26m x 30m x 485m caverns, located at 150 - 200 m below the ground surface in a granitic rock, are under construction. By systematically monitoring the pressure responses between the neighboring boreholes during drilling of total 387 boreholes around the two propane caverns, a spatial profile of the hydraulic connections and hydraulic conductivity around the caverns has been successfully obtained. Locations of localized depressurized zones created during an arch excavation have been detected by monitoring pressure in each borehole after stopping water supply to that borehole temporarily. Measurement has been conducted using each one of the 302 boreholes, one at a time. Observation shows that there is a clear correlation between total pressure drop and pressure gradient versus time curve on semi-logarithmic plot, dH/log10t, as expected by the numerical prediction. Regions where dH/log10t is larger than a certain criteria, determined by a numerical simulation for flow around a cavern in a rock with uniform hydraulic conductivity, have been evaluated as a depressurized zone caused by insufficient water supply, possibly due to existence of the high permeable zones. Separate pore pressure measurement around the caverns also supports this interpretation that a low pressure is prevailing near the borehole where a large value of dH/log10t is obtained. As a countermeasure to avoid further depressurization, installation of additional water injection hole was conducted. The same observation was then repeated. It is recognized that dH/log10t has recovered above the criteria, showing that the local water balance has been improved. Finally it is concluded that the proposed rather simple but space encompassing observation is applicable to groundwater management during construction and also provides useful information for creating a hydrogeological model, considering a fracture network system, that will be used for the evaluation of the cavern performance as a storage tank.

  4. Groundwater and surface-water interaction and potential for underground water storage in the Buena Vista-Salida Basin, Chaffee County, Colorado, 2011

    USGS Publications Warehouse

    Watts, Kenneth R.; Ivahnenko, Tamara I.; Stogner, Sr., Robert W.; Bruce, James F.

    2014-01-01

    By 2030, the population of the Arkansas Headwaters Region, which includes all of Chaffee and Lake Counties and parts of Custer, Fremont, and Park Counties, Colorado, is forecast to increase about 73 percent. As the region’s population increases, it is anticipated that groundwater will be used to meet much of the increased demand. In September 2009, the U.S. Geological Survey, in cooperation with the Upper Arkansas Water Conservancy District and with support from the Colorado Water Conservation Board; Chaffee, Custer, and Fremont Counties; Buena Vista, Cañon City, Poncha Springs, and Salida; and Round Mountain Water and Sanitation District, began a 3-year study of groundwater and surface-water conditions in the Buena Vista-Salida Basin. This report presents results from the study of the Buena Vista-Salida Basin including synoptic gain-loss measurements and water budgets of Cottonwood, Chalk, and Browns Creeks, changes in groundwater storage, estimates of specific yield, transmissivity and hydraulic conductivity from aquifer tests and slug tests, an evaluation of areas with potential for underground water storage, and estimates of stream-accretion response-time factors for hypothetical recharge and selected streams in the basin. The four synoptic measurements of flow of Cottonwood, Chalk, and Browns Creeks, suggest quantifiable groundwater gains and losses in selected segments in all three perennial streams. The synoptic measurements of flow of Cottonwood and Browns Creeks suggest a seasonal variability, where positive later-irrigation season values in these creeks suggest groundwater discharge, possibly as infiltrated irrigation water. The overall sum of gains and losses on Chalk Creek does not indicate a seasonal variability but indicates a gaining stream in April and August/September. Gains and losses in the measured upper segments of Chalk Creek likely are affected by the Chalk Cliffs Rearing Unit (fish hatchery). Monthly water budgets were estimated for selected segments of five perennial streams (Cottonwood, North Cottonwood, Chalk, and Browns Creeks, and South Arkansas River) in the Buena Vista-Salida Basin for calendar year 2011. Differences between reported diversions and estimated crop irrigation requirements were used to estimate groundwater recharge in the areas irrigated by water supplied from the diversions. The amount of groundwater recharge in all the basins varied monthly; however, the greatest amount of recharge was during June and July for Cottonwood, North Cottonwood, and Chalk Creeks and South Arkansas River. The greatest amount of recharge in 2011 in Browns Creek occurred in July and August. The large seasonal fluctuations of groundwater near irrigated areas in the Buena Vista-Salida Basin indicate that the increased groundwater storage resulting from infiltration of surface-water diversions has dissipated by the following spring. Areas within the Buena Vista-Salida Basin with the potential for underground storage were identified using geographic information system data, including topographic, geologic, and hydrologic data, excluding the mountainous areas that border the Buena Vista-Salida Basin and igneous and metamorphic rock outcrop areas. The areas that met the selection criteria for underground water storage are located on terrace deposits near the Arkansas River and adjacent to its major tributaries. The selected areas also contain much of the irrigated land within the basin; consequently, irrigation ditches and canals could provide a means of conveying water to potential recharge sites.

  5. Underground Test Area Calendar Year 2014 Annual Sampling Analysis Report Nevada National Security Site, Nevada, Revision 0

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Farnham, Irene

    2016-12-01

    This report presents the analytical data for the 2014 fiscal year (FY) and calendar year (CY) (October 1, 2013, through December 31, 2014), and an evaluation of the data to ensure that the Sampling Plan’s objectives are met. In addition to samples collected and analyzed for the Sampling Plan, some NNSS wells are monitored by NNSA/NFO to demonstrate compliance with State-issued water discharge permits; with protection of groundwater from ongoing radiological waste disposal activities (compliance wells); and to demonstrate that the onsite drinking water supply is below SDWA maximum contaminant levels (MCLs) (public water system [PWS] wells). While not allmore » sampled locations are required by the Sampling Plan, these samples are relevant to its objectives and are therefore presented herein for completeness purposes. Special investigations that took place in 2014 that are relevant to the Sampling Plan are also presented. This is the first annual report released to support Sampling Plan implementation.« less

  6. Meteoric phreatic speleothems and the development of cave stratigraphy: An example from Tounj Cave, Dinarides, Croatia

    NASA Astrophysics Data System (ADS)

    Babić, Ljubomir; Lacković, Damir; HorvatinČIĆ, Nada

    Speleothems occurring in some caves of the carbonate Dinarides line all channel surfaces, and have been deposited from meteoric waters under phreatic conditions. Such phreatic speleothemic deposition modifies common experience (l) that meteoric phreatic conditions cause dissolutional widening of cave voids, and (2) that speleothems imply vadose conditions. The phreatic speleothems described here postdate an early polygenetic evolution of the cave voids, and predate the last, vadose stage. They were likely produced during the late/postglacial warming period, when dissolved carbonate was amply supplied, and when there was much water available for saturation of underground voids. Phreatic speleothems may be used as a tool for time correlation of internal deposits, both within one cave and within a karst region. They indicate an important stage in the history of the ground-water regime of an area. In general, phreatic speleothems help in better understanding of the development of subterranean voids and related karst/palaeokarst.

  7. Diagnosis of the Ghiss Nekor aquifer in order to elaborate the aquifer contract

    NASA Astrophysics Data System (ADS)

    Baite, Wissal; Boukdir, A.; Zitouni, A.; Dahbi, S. D.; Mesmoudi, H.; Elissami, A.; Sabri, E.; Ikhmerdi, H.

    2018-05-01

    The Ghiss-Nekor aquifer, located in the north-east of the action area of the ABHL, plays a strategic role in the drinkable water supply of the city of Al Hoceima and of the neighboring urban areas. It also participates in the irrigation of PMH. However, this aquifer has problems such as over-exploitation and pollution. In the face of these problems, the only Solution is the establishment of a new mode of governance, which privileges the participation, the involvement and the responsibility of the actors concerned in a negotiated contractual framework, namely the aquifer contract. The purpose of this study is to diagnose the current state of the Ghiss Nekor aquifer, the hydrogeological characterization of the aquifer, the use of the waters of the aquifer, the Problem identification and the introduction of the aquifer contract, which aims at the participatory and sustainable management of underground water resources in the Ghiss- Nekor plain, to ensure sustainable development.

  8. Management Proposals of the Sabinas Reynosa Aquifer in Northeast Mexico, and Implications in the Development of Main Towns in Chihuahua

    NASA Astrophysics Data System (ADS)

    Sanchez, E. E.

    2008-12-01

    The Sabinas Reynosa water table aquifer is located in northeast Mexico in the state of Chihuahua, where this hydrologic unit is controlled by Laramide structures. The hydrostratigraphy consists of three units. At the base is a slightly compacted conglomerate HU1. The middle unit HU2 consists of clay materials packed with a carbonate cement. The upper unit is constituted by a sandy caliche with a calcareous matrix with secondary porosity, which allows it to store and transmit large volumes of water. The three units are of Paleogene age. Recently, the towns near the Sabinas Reynosa aquifer have presented supply problems, thus, this project will determine the hydrologic characterization using the groundwater budget method in order to establish the volume of water that the aquifer will yield per unit of time. The first phase consisted of defining the balance equation, by establishing the terms involved in the budget and calculating their respective values. Two different factors were defined: the inflows and outflows. In the first case, underground inflow with 225.68 Mm3 in the last five years, recharge by irrigation with 32.08 Mm3 and anthropogenic recharge with 270.50 Mm3 were considered. In the second case, the factors include underground outflow with 359.55 Mm3, pumping with 561.43 Mm3 and evapotranspiration from the water table with 130.61 Mm3. Although this last variable was calculated on a preliminary basis, a more accurate estimate requires additional studies (in process), with the aim of obtaining a more representative value. In this work is considered that evapotranspiration takes a decisive role in the analysis of the budget and hence, in the decisions that have to be taken for the proper management of the hydrological system.

  9. An Integrated Environment Monitoring System for Underground Coal Mines—Wireless Sensor Network Subsystem with Multi-Parameter Monitoring

    PubMed Central

    Zhang, Yu; Yang, Wei; Han, Dongsheng; Kim, Young-Il

    2014-01-01

    Environment monitoring is important for the safety of underground coal mine production, and it is also an important application of Wireless Sensor Networks (WSNs). We put forward an integrated environment monitoring system for underground coal mine, which uses the existing Cable Monitoring System (CMS) as the main body and the WSN with multi-parameter monitoring as the supplementary technique. As CMS techniques are mature, this paper mainly focuses on the WSN and the interconnection between the WSN and the CMS. In order to implement the WSN for underground coal mines, two work modes are designed: periodic inspection and interrupt service; the relevant supporting technologies, such as routing mechanism, collision avoidance, data aggregation, interconnection with the CMS, etc., are proposed and analyzed. As WSN nodes are limited in energy supply, calculation and processing power, an integrated network management scheme is designed in four aspects, i.e., topology management, location management, energy management and fault management. Experiments were carried out both in a laboratory and in a real underground coal mine. The test results indicate that the proposed integrated environment monitoring system for underground coal mines is feasible and all designs performed well as expected. PMID:25051037

  10. An integrated environment monitoring system for underground coal mines--Wireless Sensor Network subsystem with multi-parameter monitoring.

    PubMed

    Zhang, Yu; Yang, Wei; Han, Dongsheng; Kim, Young-Il

    2014-07-21

    Environment monitoring is important for the safety of underground coal mine production, and it is also an important application of Wireless Sensor Networks (WSNs). We put forward an integrated environment monitoring system for underground coal mine, which uses the existing Cable Monitoring System (CMS) as the main body and the WSN with multi-parameter monitoring as the supplementary technique. As CMS techniques are mature, this paper mainly focuses on the WSN and the interconnection between the WSN and the CMS. In order to implement the WSN for underground coal mines, two work modes are designed: periodic inspection and interrupt service; the relevant supporting technologies, such as routing mechanism, collision avoidance, data aggregation, interconnection with the CMS, etc., are proposed and analyzed. As WSN nodes are limited in energy supply, calculation and processing power, an integrated network management scheme is designed in four aspects, i.e., topology management, location management, energy management and fault management. Experiments were carried out both in a laboratory and in a real underground coal mine. The test results indicate that the proposed integrated environment monitoring system for underground coal mines is feasible and all designs performed well as expected.

  11. Geology and ground water in Door County, Wisconsin, with emphasis on contamination potential in the Silurian dolomite

    USGS Publications Warehouse

    Sherrill, Marvin G.

    1977-01-01

    Door County, a recreational and fruit-growing area bordering Lake Michigan in northeastern Wisconsin, has had a long history of ground-water contamination from surface and near-surface sources. Contamination is most severe in late summer when fruit-canning operations and the influx of tourists create additional wastes. Silurian dolomite is the upper bedrock unit in the county and yields generally adequate supplies of very hard water with locally objectionable concentrations of iron and nitrate. Thin soil cover and well-fractured dolomitic bedrock give easy entry to ground-water contaminants throughout large parts of Door County. Many contaminants enter the dolomite by surface or near-surface seepage. There is little attenuation of contamination concentrations in the well-jointed dolomite, and contaminants may travel long distances underground in a relatively short time. The major source of ground-water contamination is bacteria, from individual waste-disposal systems, agricultural, industrial, and municipal wastes. Areas of the county underlain by contaminated zones include only a small percentage of the total ground-water system and are separated by large volumes of ground water free of contamination. (Woodard-USGS)

  12. Ground-water situation in Oregon

    USGS Publications Warehouse

    Newcomb, R.C.

    1951-01-01

    The water that occurs beneath the land surface follows definite and well-known rules of hydraulics, the same as water on the surface. However, ground water must be studied by methods, some of which are unique to that type of water occurrence, in order to evaluate the part it plays in the over-all water scheme.Water that falls on the land surface as rain or snow and water that rests upon the surface may in places pass laterally or downward through the pores of the earth materials. There it may take one or more of a variety of paths before again flowing out on the surface or being expelled to the atmosphere by evaporation and by the transpiration of plants. Water so diverted underground is delayed or diverted from its course toward the sea and that digression results in many services of prime importance to mankind. Underground, the water generally exceeds in total quantity the water present on the land surface at any one time.The discussion of ground water can be clarified somewhat by a description of the major parts or phases of the normal path of water underground.

  13. Development of IoT-based Urban Sinkhole and Road Collapse Monitoring System

    NASA Astrophysics Data System (ADS)

    Jung, B.; Bang, E.; Lee, H. J.; Jeong, S. W.; Ryu, D.; Kim, S. W.; Kim, B. K.; Yum, B. W.; Lee, I. H.

    2015-12-01

    The consortium of Korean government-funded research institutes is developing IoT- (Internet of things) based underground safety monitoring and alerting system to manage risks arisen from land subsidence and road collapses in metropolitan areas in South Korea. The system consists of four major functional units: subsurface monitoring sensors sending data directly through the internet, centralized servers capable of collecting and processing big data, computational modules providing physical and statistical models for predicting high-risk areas, and geologic information service platforms visualizing underground safety maps for the public. The target urban area will be regionally covered by multi-sensors monitoring soil and groundwater conditions, and by high resolution satellite InSAR images filtering vertical land movements in a centimeter scale. Integrity of buried water supply and sewer lines are also monitored for the possibility of underground cavity formation. Once high-risk area is predicted, more tangible surveying methods such as ground penetrating radar (GPR) and resistivity survey can be applied for locating the cavities. Additionally, laboratory and field experiments are performed to understand overall road collapsing mechanism from the initial cavity creation to its progressive development depending on soil types, degree of compaction, and groundwater condition. Acquired results will update existing fully-coupled hydromechanical models for more accurate prediction of the collapsing-vulnerable area. Preliminary laboratory experiments show that the upward propagation of subsurface cavity is closely related to the soil properties, such as sand-clay ratios and moisture contents, and groundwater dynamics.

  14. Water resources of the Pittsburgh area, Pennsylvania

    USGS Publications Warehouse

    Noecker, Max; Greenman, D.W.; Beamer, N.H.

    1954-01-01

    The per capita use of water in the Pittsburgh area in 1951 was 2, 000 gallons per day fgpd) or twice the per capita use in Pennsylvania as a whole. An average of about 3, 040 million gallons of water was withdrawn from the streams and from the ground each day. Of this amount, nearly 190 million gallons per day (mgd), or 6 percent, was for domestic public water supply. Industry, including public utilities generating steam for electric energy, used approximately 2, 900 mgd, of which about 42 mgd was purchased from public supply sources. In spite of this tremendous demand for water, a sufficient quantity was available to satisfy the needs of the area without serious difficulty. Acid mine drainage presents the greatest single pollution problem in the Pittsburgh area at the present time (1953) because no practical means has been found for its control. The waters of several of the rivers are strongly acid for this reason. Of the three major rivers in the area, Monongahela River waters have the greatest acid concentration and Allegheny River waters the least. Untreated domestic and industrial wastes are additional sources of stream pollution in the area. Much of the water is hard and corrosive, and occasionally has objectionable color, odor, and taste. The treatment used by public water-supply systems using river water is adequate at all times for removal of water-borne causes of disease. Attention is being concentrated on improving the quality of present supplies rather than developing new supplies from upstream tributaries. Present supplies are being improved by providing treatment facilities for disposal of wastes,, by reduction of acid mine drainage discharged into the streams, and by providing storage to augment low flows. The underground water resources are vitally important to the area. The use of ground water in the Pittsburgh area has doubled in the past two decades and in 1951 more ground water was used in Allegheny County than in any other county in Pennsylvania. On the average about 63 mgd was pumped from the ground, not including 1.5 mgd pumped for air conditioning. Most of the present-day wells in the "Triangle area" of Pittsburgh have large yields and many operate continuously throughout the summer. The result has been a marked seasonal decline in water levels in some parts of the Triangle area, especially near the center of pumping. It appears that the maximum rate of summertime use has been reached in this localized area. Water from wells near rivers often has chemical characteristics similar to those of water from the adjacent stream because the well water is supplied largely by river infiltration. The ground water in the Pittsburgh area is generally more highly mineralized than surface water, harder, and contains higher concentrations of iron and manganese, all the result of solution of aquifer minerals by the water during its passage through the ground. Nevertheless, ground water commonly is less corrosive than surface water, contains little or no suspended sediment, and is free of pathogenic bacteria. Both sediment and bacteria are present in considerable quantities in the river water of this area. Water from wells supplied largely by river infiltration may have a temperature variation throughout a year of as much as 30 to 35 F and a variation in hardness of as much as 130 ppm. Certain types of chemicals having objectionable tastes and odors are not always removed by the natural infiltration of the river water to wells but pathogenic bacteria and sediment are. There is only a small range throughout a year in the temperature and chemical quality of water in individual wells farther from the rivers. Such water is generally harder and contains more dissolved solids than water supplied by river infiltration. There is no immediate likelihood of a shortage of water in the area. Present withdrawals of surface water are spread throughout the major river valleys so that the water returned to the stream after use is available for reuse in essentially undiminished quantity. Ground-water use can be increased manyfold without depleting the supply if advantage is taken of the favorable opportunities for inducing the infiltration of surface water into the alluvial aquifers in the major stream valleys. Ground-water recharge supplied by the rivers will reduce the local flow of the rivers by the amount of the infiltration; however most of the ground water used is discharged to streams near the areas of withdrawal.

  15. Hydrogeologic information on the Glorieta Sandstone and the Ogallala Formation in the Oklahoma Panhandle and adjoining areas as related to underground waste disposal

    USGS Publications Warehouse

    Irwin, James Haskell; Morton, Robert B.

    1969-01-01

    The Oklahoma Panhandle and adjacent areas in Texas, Kansas, Colorado, and New Mexico have prospered because of the development of supplies of fresh water and of oil and gas. The Ogallala and, in places, Cretaceous rocks produce fresh water for irrigation, public supply, and domestic and stock use through approximately 9,000 irrigation and public supply wells and a large but undetermined number of other wells. Disposal of oil-field brine and other wastes into the Glorieta Sandstone is of concern to many local residents because of the possibility of pollution of the overlying fresh-water aquifers, particularly the Ogallala Formation. Permits for 147 disposal wells into the Glorieta have been issued in this area. This report summarizes the data on geology, hydrology, and water development currently available to the U.S. Geological Survey. Geologic information indicates that, in the report area, the Glorieta Sandstone lies at depths ranging from about 500 to 1,600 feet below the base of the Ogallala Fox, nation. The rocks between those two formations are of relatively impermeable types, but solution and removal of salt has resulted in collapse of the rocks in some places. Collapse and fracturing of the rocks could result in increased vertical permeability. This might result in movement of brine under hydrostatic head from the Glorieta Sandstone into overlying fresh-water aquifers, in places where an upward hydraulic gradient exists or is created by an increase in pressure within the Glorieta. Abandoned or inadequately sealed boreholes also are possible conduits for such fluids. The mixing of water in the fresh-water aquifers with brines injected into the Glorieta is not known to have occurred anywhere in the report area, but the information available is not adequate to show positively whether or not this may have occurred locally. Much additional information on the stratigraphy and hydrology--particularly, data on the potentiometric surface of water in the Glorieta--needs to be collected and analyzed before conclusions can be drawn regarding the possibility of vertical movement of oil-field brines from the Glorieta to fresh-water aquifers above.

  16. Prediction and innovative control strategies for oxygen and hazardous gases from diesel emission in underground mines.

    PubMed

    Kurnia, Jundika C; Sasmito, Agus P; Wong, Wai Yap; Mujumdar, Arun S

    2014-05-15

    Diesel engine is widely used in underground mining machines due to its efficiency, ease of maintenance, reliability and durability. However, it possesses significant danger to the miners and mining operations as it releases hazardous gases (CO, NO, CO2) and fine particles which can be easily inhaled by the miners. Moreover, the diesel engine consumes significant amount of oxygen which can lead to insufficient oxygen supply for miners. It is therefore critical to maintain sufficient oxygen supply while keeping hazardous gas concentrations from diesel emission below the maximum allowable level. The objective of this study is to propose and to examine various innovative ventilation strategies to control oxygen and hazardous gas concentrations in underground mine to ensure safety, productivity and cost related to energy consumption. Airflow distribution, oxygen and hazardous gas dispersion as well as ambient temperature within the mining area are evaluated by utilizing the well-established computational fluid dynamics (CFD) approach. The results suggest that our newly proposed ventilation design performs better as compared to the conventional design to handle hazardous gases from diesel emission. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Longevity of acid discharges from underground mines located above the regional water table.

    PubMed

    Demchak, J; Skousen, J; McDonald, L M

    2004-01-01

    The duration of acid mine drainage flowing out of underground mines is important in the design of watershed restoration and abandoned mine land reclamation projects. Past studies have reported that acid water flows from underground mines for hundreds of years with little change, while others state that poor drainage quality may last only 20 to 40 years. More than 150 above-drainage (those not flooded after abandonment) underground mine discharges from Pittsburgh and Upper Freeport coal seams were located and sampled during 1968 in northern West Virginia, and we revisited 44 of those sites in 1999-2000 and measured water flow, pH, acidity, Fe, sulfate, and conductivity. We found no significant difference in flows between 1968 and 1999-2000. Therefore, we felt the water quality data could be compared and the data represented real changes in pollutant concentrations. There were significant water quality differences between year and coal seam, but no effect of disturbance. While pH was not significantly improved, average total acidity declined 79% between 1968 and 1999-2000 in Pittsburgh mines (from 66.8 to 14 mmol H+ L(-1)) and 56% in Upper Freeport mines (from 23.8 to 10.4 mmol H+ L(-1)). Iron decreased an average of about 80% across all sites (from an average of 400 to 72 mg L(-1)), while sulfate decreased between 50 and 75%. Pittsburgh seam discharge water was much worse in 1968 than Upper Freeport seam water. Twenty of our 44 sites had water quality information in 1980, which served as a midpoint to assess the slope of the decline in acidity and metal concentrations. Five of 20 sites (25%) showed an apparent exponential rate of decline in acidity and iron, while 10 of 20 sites (50%) showed a more linear decline. Drainage from five Upper Freeport sites increased in acidity and iron. While it is clear that surface mines and below-drainage underground mines improve in discharge quality relatively rapidly (20-40 years), above-drainage underground mines are not as easily predicted. In total, the drainage from 34 out of 44 (77%) above-drainage underground mines showed significant improvement in acidity over time, some exponentially and some linearly. Ten discharges showed no improvement and three of these got much worse.

  18. Solar project description for First Baptist Church, Aberdeen, South Dakota

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1979-05-01

    The solar energy system at the First Baptist Church in Aberdeen, South Dakota is described. The solar energy system was built into the new 12,350 square foot church to heat the church and to provide domestic hot water. The 1404 square foot collector array of Solaron double glazed, flat black, flat plate collectors is mounted to the roof at a tilt angle of 30/sup 0/ from the horizontal. Thermal energy is stored in an 1100 cubic foot rock box that is located underground beneath the church. The box is filled with 35 tons of cleaned, washed rocks ranging in sizemore » from 3/4 to 1 1/2 inches. Solar space heating is provided by either the collector array directly or by rock box. Auxiliary space heating is provided by a 1,375,000 Btu electric boiler. Domestic hot water is preheated through a coil in the collector supply duct and stored in a 120 gallon tank. Auxiliary heating of the domestic hot water is provided by a 119 gallon electric water heater.« less

  19. Superfund Record of Decision (EPA Region 1): Stamina Mills site, North Smithfield, RI. (First remedial action), September 1990. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1990-09-28

    The five-acre Stamina Mills site is a former textile weaving and finishing facility in North Smithfield, Providence County, Rhode Island. A portion of the site is within the 100-year floodplain and wetland area of the Branch River. The manufacturing process used cleaning solvents, acids, bases and dyes for coloring, pesticides for moth proofing, and plasticizers to coat fabrics. Mill process wastes were placed in a landfill onsite. EPA initiated three removal actions from 1984 to 1990, including an extension of the municipal water supply to residents obtaining water from the affected aquifer; and treatment of two underground and one above-groundmore » storage tanks, followed by offsite disposal. The Record of Decision (ROD) provides a final remedy and addresses both source control and management of contaminated ground water migration at the site. The primary contaminants of concern affecting the soil, debris, sediment, and ground water are VOCs including TCE and PCE; other organics including pesticides; and metals including chromium.« less

  20. Underground mineral extraction

    NASA Technical Reports Server (NTRS)

    Miller, C. G.; Stephens, J. B.

    1980-01-01

    A method was developed for extracting underground minerals such as coal, which avoids the need for sending personnel underground and which enables the mining of steeply pitched seams of the mineral. The method includes the use of a narrow vehicle which moves underground along the mineral seam and which is connected by pipes or hoses to water pumps at the surface of the Earth. The vehicle hydraulically drills pilot holes during its entrances into the seam, and then directs sideward jets at the seam during its withdrawal from each pilot hole to comminute the mineral surrounding the pilot hole and combine it with water into a slurry, so that the slurried mineral can flow to a location where a pump raises the slurry to the surface.

  1. Impact on Hydrological Flows and Water Quality Using the Swat Model - the Case of Piracicaba Watershed

    NASA Astrophysics Data System (ADS)

    Queiroz, M. R.; Rocha, H.

    2013-05-01

    Understanding the functionality of water cycle in Brazilian ecosystems is one of the factors that generate the power to formulate smart strategies for biodiversity conservation and sustainable productivity in agro-ecosystems, promoting the generation of information that support the demands of occupation. Good policy formulation of land use depends on the expected climate change in the coming decades, as well as, surface cover and management must adapt to the socio-economic regional vocations so as to cause minimal impact. The changes in the land use influence the quantity and quality of water, contributing to floods and environmental changes. Additionally, climate change and variability, either natural or manmade cause, directly affect the human life. One of the main effects of weather occurs in the runoff generated in the basins, which in turn affects the water supply and demand in various sectors such as supply, irrigation and energy. The results Will show the impacts of climate variability on water resources (quantity and quality) to the Piracicaba watershed, through numerical modeling SWAT (Soil and Water Assessment Tool), developed with the objective to analyze the impacts of changes in land use on runoff and underground production of sediment and water quality. The results of this proposal will provide information to answer better understanding of the ecological functionality and freshwater ecosystems in Brazil, and particularly in the study region in the state of São Paulo, increase the predictability of the Earth's climate system, from knowledge of the response of terrestrial biota to different forms of climate variability and increased knowledge of alternative socio-economic adaptation of terrestrial biota and climate change.

  2. Manual of good practices for sanitation in coal mining operations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    The purpose of the manual was to act as a guideline, setting reasonable recommendations relative to mine sanitation which will enable mines to install adequate facilities and make appropriate alterations conserving and improving the health and welfare of the mine worker. A systematic evaluation was undertaken of the sanitation facilities and maintenance at coal mines. Consideration was given to central facilities including building, floors, walls, partitions, ceilings, lockers, baskets and benches, showers, toilets, lavatories, lighting, ventilation and temperature control, and maintenance. Also discussed were food vending machines, water source, water quality, water treatment, water delivery systems for underground and surfacemore » mines, sanitary waste disposal, workplace toilets in underground and surface mines, refuse control and handling for underground and surface mines, and pest control.« less

  3. 30 CFR 75.1107-8 - Fire suppression devices; extinguishant supply systems.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Protection Fire Suppression Devices and Fire-Resistant Hydraulic Fluids on Underground Equipment § 75.1107-8... liquid chemical to protect attended equipment shall: (1) Be maintained at a pressure consistent with the...

  4. 30 CFR 75.1107-8 - Fire suppression devices; extinguishant supply systems.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Protection Fire Suppression Devices and Fire-Resistant Hydraulic Fluids on Underground Equipment § 75.1107-8... liquid chemical to protect attended equipment shall: (1) Be maintained at a pressure consistent with the...

  5. 40 CFR 194.53 - Consideration of underground sources of drinking water.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Consideration of underground sources of drinking water. 194.53 Section 194.53 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) RADIATION PROTECTION PROGRAMS CRITERIA FOR THE CERTIFICATION AND RE-CERTIFICATION OF THE WASTE ISOLATION PILOT PLANT'S COMPLIANCE WITH THE...

  6. 40 CFR 194.53 - Consideration of underground sources of drinking water.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 26 2013-07-01 2013-07-01 false Consideration of underground sources of drinking water. 194.53 Section 194.53 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) RADIATION PROTECTION PROGRAMS CRITERIA FOR THE CERTIFICATION AND RE-CERTIFICATION OF THE WASTE ISOLATION PILOT PLANT'S COMPLIANCE WITH THE...

  7. 18 CFR 157.215 - Underground storage testing and development.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 18 Conservation of Power and Water Resources 1 2012-04-01 2012-04-01 false Underground storage testing and development. 157.215 Section 157.215 Conservation of Power and Water Resources FEDERAL ENERGY... not exceed the amount specified in Table II as adjusted pursuant to § 157.208(d). These costs shall...

  8. 18 CFR 157.215 - Underground storage testing and development.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 18 Conservation of Power and Water Resources 1 2014-04-01 2014-04-01 false Underground storage testing and development. 157.215 Section 157.215 Conservation of Power and Water Resources FEDERAL ENERGY... not exceed the amount specified in Table II as adjusted pursuant to § 157.208(d). These costs shall...

  9. 18 CFR 157.215 - Underground storage testing and development.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 18 Conservation of Power and Water Resources 1 2011-04-01 2011-04-01 false Underground storage testing and development. 157.215 Section 157.215 Conservation of Power and Water Resources FEDERAL ENERGY... not exceed the amount specified in Table II as adjusted pursuant to § 157.208(d). These costs shall...

  10. 18 CFR 157.215 - Underground storage testing and development.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 18 Conservation of Power and Water Resources 1 2013-04-01 2013-04-01 false Underground storage testing and development. 157.215 Section 157.215 Conservation of Power and Water Resources FEDERAL ENERGY... not exceed the amount specified in Table II as adjusted pursuant to § 157.208(d). These costs shall...

  11. Simulation of the hydrogeologic effects of oil-shale mining on the neighbouring wetland water balance: case study in north-eastern Estonia

    NASA Astrophysics Data System (ADS)

    Marandi, Andres; Karro, Enn; Polikarpus, Maile; Jõeleht, Argo; Kohv, Marko; Hang, Tiit; Hiiemaa, Helen

    2013-11-01

    The water balance of wetlands plays an integral role in their function. Developments adjacent to wetlands can affect their water balance through impacts on groundwater flow and increased discharge in the area, and they can cause lowering of the wetland water table. A 430 km2 area was selected for groundwater modelling to asses the effect of underground mining on the water balance of wetlands in north-eastern Estonia. A nature conservation area (encompassing Selisoo bog) is within 3 km of an underground oil-shale mine. Two future mining scenarios with different areal extents of mining were modeled and compared to the present situation. Results show that the vertical hydraulic conductivity of the subsurface is of critical importance to potential wetland dewatering as a result of mining. Significant impact on the Selisoo bog water balance will be caused by the approaching mine but there will be only minor additional impacts from mining directly below the bog. The major impact will arise before that stage, when the underground mine extension reaches the border of the nature conservation area; since the restriction of activities in this area relates to the ground surface, the conservation area’s border is not sufficiently protective in relation to underground development.

  12. The development of deep karst in the anticlinal aquifer structure based on the coupling of multistage flow systems

    NASA Astrophysics Data System (ADS)

    Xu, M.; Zhong, L.; Yang, Y.

    2017-12-01

    Under the background of neotectonics, the multistage underground flow system has been form due the different responses of main stream and tributaries to crust uplift. The coupling of multistage underground flow systems influences the development of karst thoroughly. At first, the research area is divided into vadose area, shunted area and exorheic area based on the development characteristics of transverse valley. Combining the controlling-drain action with topographic index and analyzing the coupling features of multistage underground flow system. And then, based on the coupling of multistage underground flow systems, the characteristics of deep karst development were verified by the lossing degree of surface water, water bursting and karst development characteristics of tunnels. The vadose area is regional water system based, whose deep karst developed well. It resulted the large water inflow of tunnels and the surface water drying up. The shunted area, except the region near the transverse valleys, is characterized by regional water system. The developed deep karst make the surface water connect with deep ground water well, Which caused the relatively large water flow of tunnels and the serious leakage of surface water. The deep karst relatively developed poor in the regions near transverse valleys which is characterized by local water system. The exorheic area is local water system based, whose the deep karst developed poor, as well as the connection among surface water and deep ground water. It has result in the poor lossing of the surface water under the tunnel construction. This study broadens the application field of groundwater flow systems theory, providing a new perspective for the study of Karst development theory. Meanwhile it provides theoretical guidance for hazard assessment and environmental negative effect in deep-buried Karst tunnel construction.

  13. Optimizing the integrated efficiency for water resource utilization:based on Economic perspective

    NASA Astrophysics Data System (ADS)

    Gao, L.; Yoshikawa, S.; Kanae, S.

    2014-12-01

    At present, total global water withdrawal is increasing and water shortage will become a crucial issue around the world. In the 2050, the water withdrawal will exceed the water which we can get it from the river and underground. One of the ways of alleviating water scarcity is increasing the efficiency of water use without development of additional water supplies. In previous literatures about water use efficiency, there are less discussion about the temporal efficiency change with corresponding characteristics of water resource. The main aim of this paper is to estimate the temporal efficiency of water use during 2011-2020 for proposing how to use efficiently the limited water. This paper used dynamic Data Envelope Analysis to estimate the efficiency which is the ratio of the sum of weighted outputs to the sum of weighted inputs. Our model uses cost of agricultural production as input indices and production value of the agriculture as output index,water withdrawal as temporal linkage. We mainly work on the two problems: Firstly, finding out the evident how much the value of water use efficiencies are in each target country; Secondly, adjusting the output value to make those countries which water use inefficiency reach to DEA efficient. The results provide a scientific reference to make rational allocation and the sustainable use of water resources would be realized.

  14. 40 CFR 146.9 - Criteria for establishing permitting priorities.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... PROGRAMS (CONTINUED) UNDERGROUND INJECTION CONTROL PROGRAM: CRITERIA AND STANDARDS General Provisions § 146...) Likelihood of contamination of underground sources of drinking water; (d) Potentially affected population; (e...

  15. 40 CFR 146.9 - Criteria for establishing permitting priorities.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... PROGRAMS (CONTINUED) UNDERGROUND INJECTION CONTROL PROGRAM: CRITERIA AND STANDARDS General Provisions § 146...) Likelihood of contamination of underground sources of drinking water; (d) Potentially affected population; (e...

  16. 40 CFR 146.9 - Criteria for establishing permitting priorities.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... PROGRAMS (CONTINUED) UNDERGROUND INJECTION CONTROL PROGRAM: CRITERIA AND STANDARDS General Provisions § 146...) Likelihood of contamination of underground sources of drinking water; (d) Potentially affected population; (e...

  17. 40 CFR 146.9 - Criteria for establishing permitting priorities.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... PROGRAMS (CONTINUED) UNDERGROUND INJECTION CONTROL PROGRAM: CRITERIA AND STANDARDS General Provisions § 146...) Likelihood of contamination of underground sources of drinking water; (d) Potentially affected population; (e...

  18. Operations Nougat and Whetstone events: Hard Hat, Danny Boy, Marshmallow, Mudpack, Wishbone, Gumdrop, Diluted Waters, and Tiny Tot, 15 February 1962-17 June 1965. Final report 15 Feb 62-19 Jun 68

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brady, W.J.; Horton, K.K.; Eubank, B.F.

    1984-01-31

    This report is a personnel oriented history of DOD participation in underground nuclear weapons testing during Operations NOUGAT and WHETSTONE, test events HARD HAT, DANNY BOY, MARSHMALLOW, MUDPACK, WISHBONE, GUMDROP, DILUTED WATERS, and TINY TOT. It is the first in a series of historical reports which will include all DOD underground nuclear weapons tests and DOE underground nuclear weapons tests with significant DOD participation from 1962 forward. In addition to these volumes presenting a history of the underground nuclear test program, a later restricted volume will identify all DOD participants, (military, civilian, and their contractors) and will list their dosimetrymore » data.« less

  19. El Nino and ground/underground water decreasing effects on coffee cultivation in DakNong Province, Vietnam by using GIS.

    NASA Astrophysics Data System (ADS)

    Duong, Anh Quan; Quy Bui, Ngoc; Luu, The Anh; Kainz, Wolfgang

    2014-05-01

    El Nino is one of most common climatic events which are widely spread over the world. In case of Vietnam, the El Nino or ENSO event has various effects on agricultural cultivation over whole country; in the Central Highlands area, the coffee cultivation also has been affected heavily. The coffee is one of most important products of this area. Our study area, the Dak Nong province located in the Central Highlands, the mountainous and highlands in central of Vietnam. The coffee production contributes roughly 40% of total GDP of the province. This province climate is influenced by tropical monsoon and high altitude terrain. The area has two seasons in which dry season from November to end of March and the wet season cover the rest. There is 80-90% of precipitation concentrated in wet season. In El Nino years, the dry season is longer and drier than normal which affects the agricultural cultivation especially coffee. The effects of El Nino phenomenon on coffee cultivation need to clarify in order to help farmers and decision makers making their solutions. The ground/underground water has been decreased by over watering of coffee growers as well as deforestation making water shortage in dry season. The over watering of coffee cultivation wasted more than 80% water resources especially underground water use. In years of 1997-1998, coffee productivity decreased 30%; in years of 2003, the coffee productivity was downed by 25%; both examples show the relation between the combination of ENSO and decreasing of Ground/underground water and the coffee production in Dak Nong province. This is a necessary research to evaluate the effects of the combination. This paper using GIS tools to estimate the effects of El Nino phenomenon combined with ground/underground water and the coffee cultivation in Dak Nong province

  20. 40 CFR 144.83 - Do I need to notify anyone about my Class V injection well?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) Geothermal energy recovery wells (40 CFR 144.81(11) and 146.5 (e)(12) of this chapter); (C) Brine return flow... protect underground sources of drinking water. (1) Such information requirements may include, but are not... other information, if needed to protect underground sources of drinking water. (2) If the Director...

  1. Geophysical logs for selected wells in the Picher Field, northeast Oklahoma and southeast Kansas

    USGS Publications Warehouse

    Christenson, Scott C.; Thomas, Tom B.; Overton, Myles D.; Goemaat, Robert L.; Havens, John S.

    1991-01-01

    The Roubidoux aquifer in northeastern Oklahoma is used extensively as a source of water for public supplies, commerce, industry, and rural water districts. The Roubidoux aquifer may be subject to contamination from abandoned lead and zinc mines of the Picher field. Water in flooded underground mines contains large concentrations of iron, zinc, cadmium, and lead. The contaminated water may migrate from the mines to the Roubidoux aquifer through abandoned water wells in the Picher field. In late 1984, the Oklahoma Water Resources Board began to locate abandoned wells that might be serving as conduits for the migration of contaminants from the abandoned mines. These wells were cleared of debris and plugged. A total of 66 wells had been located, cleared, and plugged by July 1985. In cooperation with the Oklahoma Water Resources Board, the U.S. Geological Survey took advantage of the opportunity to obtain geophysical data in the study area and provide the Oklahoma Water Resources Board with data that might be useful during the well-plugging operation. Geophysical logs obtained by the U.S. Geological Survey are presented in this report. The geophysical logs include hole diameter, normal, single-point resistance, fluid resistivity, natural-gamma, gamma-gamma, and neutron logs. Depths logged range from 145 to 1,344 feet.

  2. An institutional outbreak of leptospirosis in Chennai, South India.

    PubMed

    Ramakrishnan, R; Patel, M S; Gupte, M D; Manickam, P; Venkataraghavan, S

    2003-03-01

    The emergence of an outbreak of leptospirosis in a nurses' hostel in Chennai presented a challenge to identify and control the source of the outbreak. Sixty-nine residents and staff members were interviewed to assess exposure factors. Blood samples from the acute and convalescent patients were tested with the Microscopic Agglutination Test using the serovars prevalent in Chennai. Polymerase Chain Reaction (PCR) was conducted on serum and water samples. Based on preliminary investigation, control measures with standard hygienic measures were instituted. The attack rate was 35%. The epidemic curve suggested continuous or intermittent exposure to infection over a five-week period. Twenty residents (three asymptomatic) developed laboratory confirmed Leptospira icterohemorrhagiae. Residents collected water from an underground storage tank that was filled twice weekly from a mobile water tanker with a bucket on a rope, and the tank was usually left open. PCR tests confirmed the presence of leptospires from this water. Other control measures included cleaning the large backyard with its many stray dogs and rats, chlorinating water supplies, boiling drinking water and health education. No further cases occurred twelve days after implementing control measures. Access to clean water, not only for drinking but also for bathing, brushing and washing is essential to prevent water-borne outbreaks.

  3. Hydraulic characterization of overpressured tuffs in central Yucca Flat, Nevada Test Site, Nye County, Nevada

    USGS Publications Warehouse

    Halford, Keith J.; Laczniak, Randell J.; Galloway, Devin L.

    2005-01-01

    A sequence of buried, bedded, air-fall tuffs has been used extensively as a host medium for underground nuclear tests detonated in the central part of Yucca Flat at the Nevada Test Site. Water levels within these bedded tuffs have been elevated hundreds of meters in areas where underground nuclear tests were detonated below the water table. Changes in the ground-water levels within these tuffs and changes in the rate and distribution of land-surface subsidence above these tuffs indicate that pore-fluid pressures have been slowly depressurizing since the cessation of nuclear testing in 1992. Declines in ground-water levels concurrent with regional land subsidence are explained by poroelastic deformation accompanying ground-water flow as fluids pressurized by underground nuclear detonations drain from the host tuffs into the overlying water table and underlying regional carbonate aquifer. A hydraulic conductivity of about 3 x 10-6 m/d and a specific storage of 9 x 10-6 m-1 are estimated using ground-water flow models. Cross-sectional and three-dimensional ground-water flow models were calibrated to measured water levels and to land-subsidence rates measured using Interferometric Synthetic Aperture Radar. Model results are consistent and indicate that about 2 million m3 of ground water flowed from the tuffs to the carbonate rock as a result of pressurization caused by underground nuclear testing. The annual rate of inflow into the carbonate rock averaged about 0.008 m/yr between 1962 and 2005, and declined from 0.005 m/yr in 2005 to 0.0005 m/yr by 2300.

  4. 30 CFR 57.20031 - Blasting underground in hazardous areas.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL... dangerous accumulations of water, gas, mud, or fire atmosphere could be encountered, persons shall be...

  5. Translations on Near East and North Africa, Number 1613.

    DTIC Science & Technology

    1977-02-10

    THE ISRAEL ECONOMIST, Dec 76) 26 Underground Water Reserves Found in Negev (THE ISRAEL ECONOMIST, Dec 76) 30 Ousted Religious Party Girds for...CSO: 482Q 29 ISRAEL UNDERGROUND WATER RESERVES FOUND IN NEGEV Jerusalem THE ISRAEL ECONOMIST in English Dec 76 p 7 [Text] Desert agriculture...millenia have been found by the Mekorot Water Company in the heart of the Negev near Nahal Zin. When the taps were opened on experimental drillings at a

  6. 40 CFR 144.82 - What must I do to protect underground sources of drinking water?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 22 2010-07-01 2010-07-01 false What must I do to protect underground... Operators of Class V Injection Wells § 144.82 What must I do to protect underground sources of drinking... State or EPA Regional Office UIC Program to protect USDWs, and you must properly close your well when...

  7. Conceptual design of a water treatment system to support a manned Mars colony

    NASA Technical Reports Server (NTRS)

    1988-01-01

    The initial tasks addressed by the Prairie View A&M University team were the conceptual design of a breathable-air manufacturing system, a means of drilling for underground water, and a method for storing water for future use. Subsequently, the design objective of the team for the 1987-1988 academic year was the conceptual design of an integrated system for the supply of quality water for biological consumption, farming, residential and industrial use. The source of water for these applications is assumed to be artesian or subsurface. The first step of the project was to establish design criteria and major assumptions. The second step of the effort was to generate a block diagram of the expected treatment system and assign tasks to individual students. The list of processes for water purification and wastewater treatment given above suggests that there will be a need for on-site chemicals manufacturing for ion-exchange regeneration and disinfection. The third step of the project was to establish a basis for the design capacity of the system. A total need of 10,000 gal/day was assumed to be required. It was also assumed that 30,000 gallon raw-water intake volume is needed to produce the desired effluent volume.

  8. [Ground water improvement in the Ruhr--then and now].

    PubMed

    Schmidt, W D

    1989-05-01

    The waterworks founded during the second half of the last century obtained the raw water exclusively from the Ruhr-valley; they were responsible for the water supply of the industrial area situated on the right of the river Rhine. The rapidly growing water demand, limited possibilities in water catchment, the very bad quality of the Ruhr-water and epidemic typhoid fever required new methods in the water supply. Consequently, the Hygiene-Institute of Gelsenkirchen was founded and a new method of water production developed: the artificial ground water recharge. In 1913 two associations were founded: the Ruhrtalsperrenverein responsible for the provision of water quantity, and the Ruhrverband, responsible for the improvement of water quality. These associations formed the essential base for the rapid development of the so-called "Revier". In spite of the excellent elimination of bacteria by artificial ground water recharge-operating according to the principle of slow sand filtration-a disinfection of drinking water with chlorine became necessary; this disinfection was started in 1910 by the waterworks of the Ruhr. The construction of reservoirs and clarification plants ameliorated temporary the overall situation in water resources management. These improvements were, however, destroyed by consequences arising from the rapid economical growth before the second world war and the following break-down. After this period, great efforts were necessary to enlarge the reservoirs and increase the capacity of sewage plants. The waterworks pre-purified the water from the Ruhr before infiltration into the underground in order to increase the quantity and quality of the recharged water. Downstream, the number of sewage plants increased; a more and more refined method of analysis indicates now the pollution load of the raw ater and signalized trends which lead to further treatment measures or to the change of existing ones like substitution of chlorine by chlorine-dioxide. The artificial ground water recharge-because of its many advantages-should always be the nucleus of water treatment of the river Ruhr. For the sake of the natural character of water catchment and in order not to degrade the waterworks to mere "water-manufacturers", we are all requested to handle thoroughly and cautiously water-endangering substances.

  9. Numerical modeling of underground storage system for natural gas

    NASA Astrophysics Data System (ADS)

    Ding, J.; Wang, S.

    2017-12-01

    Natural gas is an important type of base-load energy, and its supply needs to be adjusted according to different demands in different seasons. For example, since natural gas is increasingly used to replace coal for winter heating, the demand for natural gas in winter is much higher than that in other seasons. As storage systems are the essential tools for balancing seasonal supply and demand, the design and simulation of natural gas storage systems form an important research direction. In this study, a large-scale underground storage system for natural gas is simulated based on theoretical analysis and finite element modeling.It is proven that the problem of axi-symmetric Darcy porous flow of ideal gas is governed by the Boussinesq equation. In terms of the exact solution to the Boussinesq equation, the basic operating characteristics of the underground storage system is analyzed, and it is demonstrated that the propagation distance of the pore pressure is proportional to the 1/4 power of the mass flow rate and to the 1/2 power of the propagation time. This quantitative relationship can be used to guide the overall design of natural gas underground storage systems.In order to fully capture the two-way coupling between pore pressure and elastic matrix deformation, a poro-elastic finite element model for natural gas storage is developed. Based on the numerical model, the dynamic processes of gas injection, storage and extraction are simulated, and the corresponding time-dependent surface deformations are obtained. The modeling results not only provide a theoretical basis for real-time monitoring for the operating status of the underground storage system through surface deformation measurements, but also demonstrate that a year-round balance can be achieved through periodic gas injection and extraction.This work is supported by the CAS "100 talents" Program and the National Natural Science Foundation of China (41371090).

  10. Teleoperated control system for underground room and pillar mining

    DOEpatents

    Mayercheck, William D.; Kwitowski, August J.; Brautigam, Albert L.; Mueller, Brian K.

    1992-01-01

    A teleoperated mining system is provided for remotely controlling the various machines involved with thin seam mining. A thin seam continuous miner located at a mining face includes a camera mounted thereon and a slave computer for controlling the miner and the camera. A plurality of sensors for relaying information about the miner and the face to the slave computer. A slave computer controlled ventilation sub-system which removes combustible material from the mining face. A haulage sub-system removes material mined by the continuous miner from the mining face to a collection site and is also controlled by the slave computer. A base station, which controls the supply of power and water to the continuous miner, haulage system, and ventilation systems, includes cable/hose handling module for winding or unwinding cables/hoses connected to the miner, an operator control module, and a hydraulic power and air compressor module for supplying air to the miner. An operator controlled host computer housed in the operator control module is connected to the slave computer via a two wire communications line.

  11. Identifying and quantifying urban recharge: a review

    NASA Astrophysics Data System (ADS)

    Lerner, David N.

    2002-02-01

    The sources of and pathways for groundwater recharge in urban areas are more numerous and complex than in rural environments. Buildings, roads, and other surface infrastructure combine with man-made drainage networks to change the pathways for precipitation. Some direct recharge is lost, but additional recharge can occur from storm drainage systems. Large amounts of water are imported into most cities for supply, distributed through underground pipes, and collected again in sewers or septic tanks. The leaks from these pipe networks often provide substantial recharge. Sources of recharge in urban areas are identified through piezometry, chemical signatures, and water balances. All three approaches have problems. Recharge is quantified either by individual components (direct recharge, water-mains leakage, septic tanks, etc.) or holistically. Working with individual components requires large amounts of data, much of which is uncertain and is likely to lead to large uncertainties in the final result. Recommended holistic approaches include the use of groundwater modelling and solute balances, where various types of data are integrated. Urban recharge remains an under-researched topic, with few high-quality case studies reported in the literature.

  12. Simulation and optimization study of a solar seasonal storage district heating system: the Fox River Valley case study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Michaels, A.I.; Sillman, S.; Baylin, F.

    1983-05-01

    A central solar-heating plant with seasonal heat storage in a deep underground aquifer is designed by means of a solar-seasonal-storage-system simulation code based on the Solar Energy Research Institute (SERI) code for Solar Annual Storage Simulation (SASS). This Solar Seasonal Storage Plant is designed to supply close to 100% of the annual heating and domestic-hot-water (DHW) load of a hypothetical new community, the Fox River Valley Project, for a location in Madison, Wisconsin. Some analyses are also carried out for Boston, Massachusetts and Copenhagen, Denmark, as an indication of weather and insolation effects. Analyses are conducted for five different typesmore » of solar collectors, and for an alternate system utilizing seasonal storage in a large water tank. Predicted seasonal performance and system and storage costs are calculated. To provide some validation of the SASS results, a simulation of the solar system with seasonal storage in a large water tank is also carried out with a modified version of the Swedish Solar Seasonal Storage Code MINSUN.« less

  13. Research for Preseismic Phenomena on the Underground Water Level and Temperature in Selected Areas of Greece

    NASA Astrophysics Data System (ADS)

    Contadakis, M. E.; Asteriadis, G.

    1997-08-01

    A comprehensive study of the tectonic activity require the contribution of a variety of methods, geological, seismic, geodetic, satellite etc., being currently available in our days. On the other hand, the risk evaluation in areas of high seismicity, like this one of the South Balkan Peninsula, is of vital importance. To this purpose an interdisciplinary following up of the tectonic activity in the area may provide the best provision to the administration for an effective confrontation and intervention for the elimination of the possible disastrous effects in human life cost, financial and social cost of the communities, to which may result a strong earthquake. Among the various methods of indirect monitoring of the tectonic activity in an area, which in addition is of a low cost, is that of the following up of the underground water level and temperature changes in the area of interest. This method is based on the fact that tectonic activity is expected to result to tectonic stresses producing alterations to the local water table which in its turn is expected is expected to be observed as variation of the underground water level and temperature. The method of the following up of the underground water and temperature changes has been applied, among others by the Department of Geodesy and Surveying of the University of Thessaloniki in two areas of high seismicity in Greece: (a) The seismic zone of the lake Volvi in North Greece (40.5 deg N and 23.5 deg E) for ten years (1983-1992) and (b) the area of South Thessaly (39.2 deg N and 21 deg E) for three years (1994-1996). The statistical analysis of the observations, shows that the low frequency constituent (Sa,Ssa,Mf,Mm) of the earth tides and the barometric pressure have a small influence on the water level measurements. The shallow underground water network of South Thessaly is more sensitive to the non tectonic factors than the network of Volvi. Tentative correlation of the underground wat! er and temperature variations with the earthquake indicate that the shocks with magnitude higher than 2.0 can be tentatively connected with water and level or temperature variations in at least one well of the network with a probability higher than 75% in both areas.

  14. Investigation of humidity using the muon component of cosmic rays

    NASA Astrophysics Data System (ADS)

    Oskomov, V.; Sedov, A.; Saduyev, N.; Kalikulov, O.; Kenzhina, I.; Naurzbayeva, A.; Alimgazinova, N.; Zhumabaev, A.; Shinbulatov, S.; Erezhep, N.

    2017-12-01

    Determination of humidity is one of the most important types of hydrometeorological and glaciological observations performed in agriculture, hydropower and water supply. The work is devoted to the development of physical basis of moisture determination method, based on attenuation of the flux of cosmic-ray muons. The relationship between the intensity of muons registered in the underground room of the Tien Shan mountain research station (Almaty) and relative humidity was studied. The results of studies show that the values of the normalized mutual correlation function between the rows of muon intensity and relative humidity vary from 0.3 to 0.7, depending on the coincidence scheme. The data obtained from the muon telescope located at the the Tien Shan mountain research station was used in the work.

  15. Tritium distribution in ground water around large underground fusion explosions

    USGS Publications Warehouse

    Stead, F.W.

    1963-01-01

    Tritium will be released in significant amounts from large underground nuclear fusion explosions in the Plowshare Program. The tritium could become highly concentrated in nearby ground waters, and could be of equal or more importance as a possible contaminant than other long-lived fission-product and induced radionuclides. Behavior of tritiated water in particular hydrologic and geologic environments, as illustrated by hypothetical explosions in dolomite and tuff, must be carefully evaluated to predict under what conditions high groundwater concentrations of tritium might occur.

  16. [Problems of epidemic safety of drinking water use by the population of Russia].

    PubMed

    Nedachin, A E; Artemova, T Z; Dmitrieva, R A; Doskina, T V; Talaeva, Iu G; Ivanova, L V; Butorina, N N; Lavrova, D V; Sanamian, A G; Zagaĭnova, A V; Aleshnia, V V; Zhuravlev, P V; Golovina, S V; Panasovets, O P; Savilov, E D; Mamontova, L M; Anganova, E V

    2005-01-01

    Quantitative relationships were studied between the indicators (common coliform bacteria (CCP), glucose-positive bacteria (GPB), thermoduric bacteria (TDB), coliform bacteria, enterococci, clostridia, coliphages) and the opportunistic (Pseudomonas aeruginosa, Proteus, Klebsiella) and pathogenetic (Salmonella and intestinal viruses) microorganisms at the stages of effluent purification and decontamination, in processes of self-purification in the water reservoirs and of water preparation at water-supplying stations, as well as in the association with the incidence of acute intestinal infections of bacterial and viral genesis in different climatic zones of the country. Salmonella and the opportunistic bacteria of the Enterobacteriaceae family and Pseudomonas aeruginosa were found to be highly resistant to detoxifying agents and environmental factors, adaptable, able to reproduce in pure water, to long survive in underground waters, and to accumulate when water is desalinated at the erections. The cases of intestinal infections were found in the population using the portable water of the standard quality in terms of E. coli, TDB, CCB, and enterococci. In this case only the wider integral index of GPB, which includes the indices of E. coli, TDB, CCB, as well as lactose-negative pathogenic and opportunistic species retains its sanitary significance in terms of all signs and is a reliable indicator of the potential epidemic hazard of drinking water use. Long-term studies have provided evidence for the sanitary value of coliphages as indicators of viral drinking water contamination.

  17. Characterizing Ground-Water Flow Paths in High-Altitude Fractured Rock Settings Impacted by Mining Activities

    NASA Astrophysics Data System (ADS)

    Wireman, M.; Williams, D.

    2003-12-01

    The Rocky Mountains of the western USA have tens of thousands of abandoned, inactive and active precious-metal(gold,silver,copper)mine sites. Most of these sites occur in fractured rock hydrogeologic settings. Mining activities often resulted in mobilization and transport of associated heavy metals (zinc,cadmium,lead) which pose a significant threat to aquatic communities in mountain streams.Transport of heavy metals from mine related sources (waste rock piles,tailings impoudments,underground workings, mine pits)can occur along numerous hydrological pathways including complex fracture controlled ground-water pathways. Since 1991, the United States Environmental Protection Agency, the Colorado Division of Minerals and Geology and the University of Colorado (INSTAAR)have been conducting applied hydrologic research at the Mary Murphy underground mine. The mine is in the Chalk Creek mining district which is located on the southwestern flanks of the Mount Princeton Batholith, a Tertiary age intrusive comprised primarily of quartz monzonite.The Mount Princeton batholith comprises a large portion of the southern part of the Collegiate Range west of Buena Vista in Chaffee County, CO. Chalk Creek and its 14 tributaries drain about 24,900 hectares of the eastern slopes of the Range including the mining district. Within the mining district, ground-water flow is controlled by the distribution, orientation and permeability of discontinuities within the bedrock. Important discontinuities include faults, joints and weathered zones. Local and intermediate flow systems are perturbed by extensive underground excavations associated with mining (adits, shafts, stopes, drifts,, etc.). During the past 12 years numerous hydrological investigations have been completed. The investigations have been focused on developing tools for characterizing ground-water flow and contaminant transport in the vicinity of hard-rock mines in fractured-rock settings. In addition, the results from these investigations have been used to develop a sound conceptual model of ground-water flow and transport of heavy metals from the mine workings to Chalk Creek. Ground-water tracing techniques (using organic, fluorescent dyes) have been successfully used to delineate ground-water flow paths. Surface-water tracing techniques have been used to acquire very accurate stream flow measuements and to identify ground-water inflow zones to streams. Stable (O18/D)and radioactive (tritium,sulphur 35) isotope anlysis of waters flowing into and out of underground workings have proved useful for conducting end member mixing analysis to determine which inflows and outflows are most significant with respect to metals loading. Hydrogeologic mapping, inverse geochemical modeling (using MINTEQAK code)and helium 3 analysis of ground water have also proven to useful tools. These tools, used in combination have provided multiple lines of evidence regarding the nature, timing and magnitude of ground-water inflow into underground mine workings and the distribution and types of hydrologic pathways that transport metals from the underground workings to Chalk Creek. This paper presents the results of some of the more important hydrologic investigations completed at the site and a conceptual model of ground-water flow in fractured rock settings that have been impacted by underground mining activites.

  18. Sustainable Strategies for the Dynamic Equilibrium of the Urban Stream, Cheonggyecheon

    NASA Astrophysics Data System (ADS)

    Seo, D.; Kwon, Y.

    2018-04-01

    Cheonggyecheon, which had been transformed into a 14-lane urban highway and a large underground sewer system, was finally converted back to an urban stream again. Its transformation has been praised as a successful example of urban downtown regeneration and beautification. It is, however, obvious that there have not been prudent ecological considerations since the project’s principal goals were to provide public recreational use and achieve maximum flood control capacity via the use of embankments. For a healthier and sustainable stream environment, Cheonggyecheon should be ecologically re-restored again, based on a dynamic equilibrium model. It must primarily establish a corridor of vegetation, an aquatic transitional zone, and install constructed wetlands nearby which support the water source. The upper streams of Cheonggyecheon should be further restored and supply natural waters. Furthermore, there ultimately needs to be de-channelization for hydrological sustainability. This would vary from merely increasing the sinuosity to thoroughly reconstruct a naturalized stream. Complete dynamic equilibrium of Cheonggyecheon can be accomplished through more fundamental sustainable strategies.

  19. Estimating the magma supply rate at Kilauea volcano, Hawaii

    NASA Astrophysics Data System (ADS)

    Wright, T. L.; Klein, F. W.

    2006-12-01

    A frequent question is whether the magma supply rate to Kilauea is constant. Before seaward spreading of the south flank of Kilauea was demonstrated by the slip on a basal decollement that accompanied the M7.2 1975 south flank earthquake, the magma supply rate was equated to the identical eruption rates for three long-lived eruptions (3). Later, a continuous tilt record at Kilauea's summit was used to derive the volume of magma transported during deflations associated with rift eruptions (2), concluding that over a 30-year period about 38% of Kilauea's magma supply was left underground, but agreeing with the equivalency of overall magma supply and sustained eruption rates. Recent modeling of geodetic data gathered during Kilauea's current eruption (1) estimated a supply rate to accommodate spreading at 1.5 times the eruption rate. We approach the problem of magma supply, making two assumptions: 1. Eruption rates are controlled by the capacity of the underground transport paths to deliver magma to the surface. 2. Spreading of Kilauea's south flank is magma-driven and all space created during spreading is filled with new magma. On these premises, and in consideration of the physical properties of magma, eruption rates would have to be less than the supply rate; equivalence would imply a rigid edifice in which an open channel could deliver magma as if it were water. We are working to establish a third indicator of magma supply, the occurrence of seismic swarms in the stressed south flank. Many such swarms have been previously identified in association with documented eruptions and intrusions, but other swarms occur independently and may be associated with passive intrusion filling the room created during spreading. We contrast the seismic and geodetic data gathered during Kilauea's two longest monitored eruptions, Mauna Ulu (1969-1974) and Pu'u `O'o-Kupaianaha (1983-ongoing). For episodic high-fountaining episodes we calculate eruption efficiency as the ratio of erupted lava corrected for 20% vesicularity to the volume of magma calculated from summit deflation (2). Eruption rates (km3/yr) during these periods are .1068 and .1267, respectively, with eruption efficiencies of .7 and >1. Individual episodes vary in south flank seismic activity, suggesting short-term variability of the magma supply. Mauna Ulu was characterized by overall inflation of Kilauea's summit, including during continuous eruption, and by the occurrence of intrusions and eruptions elsewhere on the volcano. We interpret this as indicating a supply rate that exceeded the capacity of the plumbing to deliver magma to the surface. In contrast, the current eruption had nearly twenty years of summit deflation and almost no intrusions or eruptions elsewhere, indicating that magma was being mined from overall storage. With continuously recording GPS, a major component of magma supply can be equated to a modeled dilation associated with spreading, augmented by erupted volumes and summit inflation to ascertain the variability of supply rate. Correlation with south flank seismicity may allow even better discrimination of rates. 1. Cayol, V., et al., 2000, Science, v. 288, p. 2343-2346. 3. Dvorak, J.J., and Dzurisin, D., 1993, Jour. Geophys. Res., v. 98, no. B12, p. 22,255-22,268. 3. Swanson, D.A., 1972, Science, v. 175, no. 4018, p. 169-170.

  20. Identifying (subsurface) anthropogenic heat sources that influence temperature in the drinking water distribution system

    NASA Astrophysics Data System (ADS)

    Agudelo-Vera, Claudia M.; Blokker, Mirjam; de Kater, Henk; Lafort, Rob

    2017-09-01

    The water temperature in the drinking water distribution system and at customers' taps approaches the surrounding soil temperature at a depth of 1 m. Water temperature is an important determinant of water quality. In the Netherlands drinking water is distributed without additional residual disinfectant and the temperature of drinking water at customers' taps is not allowed to exceed 25 °C. In recent decades, the urban (sub)surface has been getting more occupied by various types of infrastructures, and some of these can be heat sources. Only recently have the anthropogenic sources and their influence on the underground been studied on coarse spatial scales. Little is known about the urban shallow underground heat profile on small spatial scales, of the order of 10 m × 10 m. Routine water quality samples at the tap in urban areas have shown up locations - so-called hotspots - in the city, with relatively high soil temperatures - up to 7 °C warmer - compared to the soil temperatures in the surrounding rural areas. Yet the sources and the locations of these hotspots have not been identified. It is expected that with climate change during a warm summer the soil temperature in the hotspots can be above 25 °C. The objective of this paper is to find a method to identify heat sources and urban characteristics that locally influence the soil temperature. The proposed method combines mapping of urban anthropogenic heat sources, retrospective modelling of the soil temperature, analysis of water temperature measurements at the tap, and extensive soil temperature measurements. This approach provided insight into the typical range of the variation of the urban soil temperature, and it is a first step to identifying areas with potential underground heat stress towards thermal underground management in cities.

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marutzky, Sam; Farnham, Irene

    The purpose of the Nevada National Security Site (NNSS) Integrated Sampling Plan (referred to herein as the Plan) is to provide a comprehensive, integrated approach for collecting and analyzing groundwater samples to meet the needs and objectives of the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Field Office (NNSA/NFO) Underground Test Area (UGTA) Activity. Implementation of this Plan will provide high-quality data required by the UGTA Activity for ensuring public protection in an efficient and cost-effective manner. The Plan is designed to ensure compliance with the UGTA Quality Assurance Plan (QAP). The Plan’s scope comprises sample collectionmore » and analysis requirements relevant to assessing the extent of groundwater contamination from underground nuclear testing. This Plan identifies locations to be sampled by corrective action unit (CAU) and location type, sampling frequencies, sample collection methodologies, and the constituents to be analyzed. In addition, the Plan defines data collection criteria such as well-purging requirements, detection levels, and accuracy requirements; identifies reporting and data management requirements; and provides a process to ensure coordination between NNSS groundwater sampling programs for sampling of interest to UGTA. This Plan does not address compliance with requirements for wells that supply the NNSS public water system or wells involved in a permitted activity.« less

  2. 30 CFR 817.180 - Utility installations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... PERMANENT PROGRAM PERFORMANCE STANDARDS PERMANENT PROGRAM PERFORMANCE STANDARDS-UNDERGROUND MINING ACTIVITIES § 817.180 Utility installations. All underground mining activities shall be conducted in a manner...; oil, gas, and coal-slurry pipelines, railroads; electric and telephone lines; and water and sewage...

  3. 4. VIEW SOUTHWEST OF 15MILLION GALLON UNDERGROUND CLEARWELL (foreground), HEAD ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    4. VIEW SOUTHWEST OF 15-MILLION GALLON UNDERGROUND CLEARWELL (foreground), HEAD HOUSE (left), OLD PUMP STATION (center), AND EAST FILTER BUILDING (background) - Dalecarlia Water Treatment Plant, 5900 MacArthur Boulevard, Northwest, Washington, District of Columbia, DC

  4. Modelling of deformation of underground tunnel lining, interacting with water-saturated soil

    NASA Astrophysics Data System (ADS)

    Berezhnoi, D. V.; Balafendieva, I. S.; Sachenkov, A. A.; Sekaeva, L. R.

    2016-11-01

    Built finite element method of calculating the deformation of underground tunnel lining, interacting with dry and water-saturated soils. To simulate the interaction between the lining and soils environments, including physical and non-linear, a special "contact" finite element, which allows to consider all cases of interaction between the contacting surfaces. It solved a number of problems of deformation with the ground subway tunnel lining rings.

  5. Effects of underground mining and mine collapse on the hydrology of selected basins in West Virginia

    USGS Publications Warehouse

    Hobba, William A.

    1993-01-01

    The effects of underground mining and mine collapse on areal hydrology were determined at one site where the mined bed of coal lies above major streams and at two sites where the bed of coal lies below major streams. Subsidence cracks observed at land surface generally run parallel to predominant joint sets in the rocks. The mining and subsidence cracks increase hydraulic conductivity and interconnection of water-bearing rock units, which in turn cause increased infiltration of precipitation and surface water, decreased evapotranspiration, and higher base flows in some small streams. Water levels in observation wells in mined areas fluctuate as much as 100 ft annually. Both gaining and losing streams are found in mined areas. Mine pumpage and drainage can cause diversion of water underground from one basin to another. Areal and single-well aquifer tests indicated that near-surface rocks have higher transmissivity in a mine-subsided basin than in unmined basins. Increased infiltration and circulation through shallow subsurface rocks increase dissolved mineral loads in streams, as do treated and untreated contributions from mine pumpage and drainage. Abandoned and flooded underground mines make good reservoirs because of their increased transmissivity and storage. Subsidence cracks were not detectable by thermal imagery, but springs and seeps were detectable.

  6. Geophysical Monitoring of Geodynamic Processes of Central Armenia Earth Crust

    NASA Astrophysics Data System (ADS)

    Avetyan, R.; Pashayan, R.

    2016-12-01

    The method of geophysical monitoring of earth crust was introduced. It allows by continuous supervision to track modern geodynamic processes of Armenia. Methodological practices of monitoring come down to allocation of a signal which reflects deformation of rocks. The indicators of deformations are not only deviations of geophysical indicators from certain background values, but also parameters of variations of these indicators. Data on changes of parameters of barometric efficiency and saw tooth oscillations of underground water level before seismic events were received. Low-amplitude periodic fluctuations of water level are the reflection of geodynamic processes taking place in upper levels of earth crust. There were recorded fluctuations of underground water level resulting from luni-solar tides and enabling to control the systems of borehole-bed in changes of voluminous deformations. The slow lowering (raising) of underground water level in the form of trend reflects long-period changes of stress-deformative state of environment. Application of method promotes identification of medium-term precursors on anomalous events of variations of geomagnetic field, change of content of subsoil radon, dynamics of level of underground water, geochemistry and water temperature. Increase of activity of geodynamic processes in Central Armenian tectonic complex is observed to change macro component Na+, Ca2+, Mg2-, CL-, SO42-, HCO3-, H4SiO4, pH and gas - CO2 structure of mineral water. Modern geodynamic movements of earth crust of Armenia are the result of seismic processes and active geodynamics of deep faults of longitudinal and transversal stretching. Key Words: monitoring, hydrogeodynamics, geomagnetic field, seismicity, deformation, earth crust

  7. Plant Functional Traits on Green Risers and Brown Treads of Periglacial Patterned Ground at Glacier National Park, Montana

    NASA Astrophysics Data System (ADS)

    Apple, M. E.; Ricketts, M. K.

    2016-12-01

    On the stair-stepped solifluction terraces of the periglacial patterned ground at Glacier National Park, Montana, the clearly visible striped pattern of green alternating with brown is formed by contrasts in the percent cover of plants with different functional traits. The sloping green risers dominated by the mat-forming dwarf shrubs, Dryas octopetela (Mountain Dryad) and Salix arctica (Arctic Willow) alternate with the relatively flat, sparsely covered brown rocky treads which are inhabitated by herbaceous, and often taprooted plants. Eleven species were restricted to the brown treads, including the rare arctic-alpine species Papaver pygmaeum (Pygmy Poppy), Aqiulegia jonesii (Jones' Columbine), Draba macounii, and Erigeron lanatus. Of these, the first three arise from taproots or branched rootcrowns. They are restricted to the brown rocky treads while E. lanatus arises from a caudex and grows on the treads and risers. The relative abundance of rare plants was significantly higher on the brown treads and no rare species were restricted to the green risers. The community weighted trait means were significantly higher for Raunkiaer cryptophytes and hemicryptophytes, graminoid, herbaceous and rosetted forms, and stolons, Underground traits varied significantly as well, since taproots, caudices, and other substantial roots had higher incidences on the brown treads than on the green risers. The brown, rocky treads are relatively flat with low percent plant cover and likely a water-stressed environment, hence the substantial investment in underground structures. In contrast, the sloped green risers are essentially covered by the mat-forming dwarf shrubs, D. octopetela and S. arctica, which augment their woody roots with the anchorage of adventitious roots and which provide shade and water retention for other plants, including seedlings of Abies lasiocarpa (Subalpine fir) and Pinus albicaulus (Whitebark Pine). Water from summer thunderstorms and seasonal melting supplies the periglacial patterned ground, which is by definition close to Glacier National Park's vanishing snowfields and glaciers, so their loss will likely influence water availability for these alpine plants.

  8. The ground-water system and possible effects of underground coal mining in the Trail Mountain area, central Utah

    USGS Publications Warehouse

    Lines, Gregory C.

    1985-01-01

    The ground-water system was studied in the Trail Mountain area in order to provide hydrologic information needed to assess the hydrologic effects of underground coal mining. Well testing and spring data indicate that water occurs in several aquifers. The coal-bearing Blackhawk-Star Point aquifer is regional in nature and is the source of most water in underground mines in the region. One or more perched aquifers overlie the Blackhawk-Star Point aquifer in most areas of Trail Mountain.Aquifer tests indicate that the transmissivity of the Blackhawk-Star Point aquifer, which consists mainly of sandstone, siltstone, and shale, ranges from about 20 to 200 feet squared per day in most areas of Trail Mountain. The specific yield of the aquifer was estimated at 0.05, and the storage coefficient is about IxlO"6 per foot of aquifer where confined.The main sources of recharge to the multiaquifer system are snowmelt and rain, and water is discharged mainly by springs and by leakage along streams. Springs that issue from perched aquifers are sources of water for livestock and wildlife on Trail Mountain.Water in all aquifers is suitable for most uses. Dissolved solids concentrations range from about 250 to 700 milligrams per liter, and the predominant dissolved constituents generally are calcium, magnesium, and bicarbonate. Future underground coal mines will require dewatering when they penetrate the Blackhawk-Star Point aquifer. A finitedifference, three-dimensional computer model was used to estimate the inflow of water to various lengths and widths of a hypothetical dewatered mine and to estimate drawdowns of potentiometric surfaces in the partly dewatered aquifer. The estimates were made for a range of aquifer properties and premining hydraulic gradients that were similar to those on Trail Mountain. The computer simulations indicate that mine inflows could be several hundred gallons per minute and that potentiometric surfaces of the partly dewatered aquifer could be drawn down by several hundred feet during a reasonable life span of a mine. Because the Blackhawk-Star Point aquifer is separated from overlying perched aquifers by an unsaturated zone, mine dewatering alone would not affect perched aquifers. Mine dewatering would not significantly change water quality in the Blackhawk-Star Point aquifer. Subsidence will occur above future underground mines, but the effects on the ground-water system cannot be quantified. Subsidence fractures possibly could extend from the roof of a mine into a perched aquifer several hundred feet above. Such fractures would increase down ward percolation of water through the perching bed, and spring discharge from the perched aquifer could decrease. Flow through subsidence fractures also could increase recharge to the Blackhawk-Star Point aquifer and increase inflows to underground mines.

  9. [Assessment of Cyto- and Genotoxicity of Underground Waters from the Far Eastern Center on Radioactive Waste Treatment Site].

    PubMed

    Oudalova, A A; Pyatkova, S V; Geras'kin, S A; Kiselev, S M; Akhromeev, S V

    2016-01-01

    This study has been completed in the frames of activities on the environment assessment in the vicinity of the Far Eastern center (FEC) on radioactive waste treatment (a branch of Fokino, Sysoev Bay). Underground waters collected at the FEC technical site were surveyed both with instrumental techniques and bioassays. Concentrations of some chemicals (ranged to the third hazard category) in the samples collected are over the permitted limits. Activities of 137Cs and 90Sr in waters amount up to 3.8 and 16.2 Bq/l, correspondingly. The integral pollution index is over 1 in all the samples and could amount up to 165. The Allium-test application allows the detection of the sample points where underground waters have an enhanced mutagenic potential. Dependencies between biological effects and pollution levels are analyzed. The findings obtained could be used for the monitoring optimized and decision making on rehabilitation measures to decrease negative influence of the enterprise on the environment.

  10. A Shallow Underground Laboratory for Low-Background Radiation Measurements and Materials Development

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aalseth, Craig E.; Bonicalzi, Ricco; Cantaloub, Michael G.

    Abstract: Pacific Northwest National Laboratory recently commissioned a new shallow underground laboratory, located at a depth of approximately 30 meters water-equivalent. This new addition to the small class of radiation measurement laboratories located at modest underground depths worldwide houses the latest generation of custom-made, high-efficiency, low-background gamma-ray spectrometers and gas proportional counters. This manuscript describes the unique capabilities present in the shallow underground laboratory; these include large-scale ultra-pure materials production and a suite of radiation detection systems. Reported data characterize the degree of background reduction achieved through a combination of underground location, graded shielding, and rejection of cosmic-ray events. Wemore » conclude by presenting measurement targets and future opportunities.« less

  11. Water prospection in volcanic islands by Time Domain Electromagnetic (TDEM) surveying: The case study of the islands of Fogo and Santo Antão in Cape Verde

    NASA Astrophysics Data System (ADS)

    Martínez-Moreno, F. J.; Monteiro-Santos, F. A.; Madeira, J.; Bernardo, I.; Soares, A.; Esteves, M.; Adão, F.

    2016-11-01

    Water demand in islands, focused in agriculture, domestic use and tourism, is usually supplied by groundwater. Thus the information about groundwater distribution is an important issue in islands water resources management. Time Domain Electromagnetic (TDEM) provides underground resistivity distribution at greater depths and is of easier application than other methods. In this study TDEM technique was used for groundwater prospection in two volcanic islands with water supply problems, the islands of Fogo and Santo Antão in the Republic of Cape Verde. The 10 islands of Cape Verde Archipelago, located off the coast of Senegal (W Africa), present a semi-arid climate and thus suffer from irregular and scarce precipitation. In the Island of Fogo 26 TDEM soundings, presenting an area distribution, were performed on the SW flank of the volcanic edifice. These allowed obtaining a 3D model composed of 5 layers parallel to the topographic surface separated by 50 m depth down to - 250 m. The results indicate the presence of the water-table at a depth of 150 m in the lower ranges of the W flank of the island, and at > 200 m depth in the area above 250 m above sea level (a.s.l.). In the Island of Santo Antão 32 TDEM soundings, distributed along 5 linear profiles, were obtained on the north-eastern half of the island. The profiles are located in two regions exposed to different humidity conditions to the N and S of the main water divide. The northern flank receives the dominant trade winds first and most of the precipitation and, therefore, the water-table is shallower ( 50 m depth) than in the S ( 100 m depth). Our study demonstrates the applicability and usefulness of the TDEM method for groundwater prospection in high resistivity contexts such as in volcanic islands.

  12. Microseismic response characteristics modeling and locating of underground water supply pipe leak

    NASA Astrophysics Data System (ADS)

    Wang, J.; Liu, J.

    2015-12-01

    In traditional methods of pipeline leak location, geophones must be located on the pipe wall. If the exact location of the pipeline is unknown, the leaks cannot be identified accurately. To solve this problem, taking into account the characteristics of the pipeline leak, we propose a continuous random seismic source model and construct geological models to investigate the proposed method for locating underground pipeline leaks. Based on two dimensional (2D) viscoacoustic equations and the staggered grid finite-difference (FD) algorithm, the microseismic wave field generated by a leaking pipe is modeled. Cross-correlation analysis and the simulated annealing (SA) algorithm were utilized to obtain the time difference and the leak location. We also analyze and discuss the effect of the number of recorded traces, the survey layout, and the offset and interval of the traces on the accuracy of the estimated location. The preliminary results of the simulation and data field experiment indicate that (1) a continuous random source can realistically represent the leak microseismic wave field in a simulation using 2D visco-acoustic equations and a staggered grid FD algorithm. (2) The cross-correlation method is effective for calculating the time difference of the direct wave relative to the reference trace. However, outside the refraction blind zone, the accuracy of the time difference is reduced by the effects of the refracted wave. (3) The acquisition method of time difference based on the microseismic theory and SA algorithm has a great potential for locating leaks from underground pipelines from an array located on the ground surface. Keywords: Viscoacoustic finite-difference simulation; continuous random source; simulated annealing algorithm; pipeline leak location

  13. Assessing GHG emissions, ecological footprint, and water linkage for different fuels.

    PubMed

    Chavez-Rodriguez, Mauro F; Nebra, Silvia A

    2010-12-15

    Currently, transport is highly dependent on fossil fuels and responsible for about 23% of world energy-related GHG (greenhouse gas) emissions. Ethanol from sugar cane and corn emerges as an alternative for gasoline in order to mitigate GHG emissions. Additionally, deeper offshore drilling projects such as in the Brazilian Pre-Salt reservoirs and mining projects of nonconventional sources like Tar Sands in Canada could be a solution for supplying demand of fossil fuels in the short and midterm. Based on updated literature, this paper presents an assessment of GHG emissions for four different fuels: ethanol from sugar cane and from corn and gasoline from conventional crude oil and from tar sands. An Ecological Footprint analysis is also presented, which shows that ethanol from sugar cane has the lowest GHG emissions and requires the lowest biocapacity per unit of energy produced among these fuels. Finally, an analysis using the Embodied Water concept is made with the introduction of a new concept, the "CO(2)-Water", to illustrate the impacts of releasing carbon from underground to atmosphere and of the water needed to sequestrate it over the life cycle of the assessed fuels. Using this method resulted that gasoline from fossil fuels would indirectly "require" on average as much water as ethanol from sugar cane per unit of fuel energy produced.

  14. Large Scale Underground Detectors in Europe

    NASA Astrophysics Data System (ADS)

    Katsanevas, S. K.

    2006-07-01

    The physics potential and the complementarity of the large scale underground European detectors: Water Cherenkov (MEMPHYS), Liquid Argon TPC (GLACIER) and Liquid Scintillator (LENA) is presented with emphasis on the major physics opportunities, namely proton decay, supernova detection and neutrino parameter determination using accelerator beams.

  15. Didymosphenia geminata in the Upper Esopus Creek: Current Status, Variability, and Controlling Factors

    PubMed Central

    George, Scott Daniel; Baldigo, Barry Paul

    2015-01-01

    In May of 2009, the bloom-forming diatom Didymosphenia geminata was first identified in the Upper Esopus Creek, a key tributary to the New York City water-supply and a popular recreational stream. The Upper Esopus receives supplemental flows from the Shandaken Portal, an underground aqueduct delivering waters from a nearby basin. The presence of D. geminata is a concern for the local economy, water supply, and aquatic ecosystem because nuisance blooms have been linked to degraded stream condition in other regions. Here we ascertain the extent and severity of the D. geminata invasion, determine the impact of supplemental flows from the Portal on D. geminata, and identify potential factors that may limit D. geminata in the watershed. Stream temperature, discharge, and water quality were characterized at select sites and periphyton samples were collected five times at 6 to 20 study sites between 2009 and 2010 to assess standing crop, diatom community structure, and density of D. geminata and all diatoms. Density of D. geminata ranged from 0–12 cells cm-2 at tributary sites, 0–781 cells cm-2 at sites upstream of the Portal, and 0–2,574 cells cm-2 at sites downstream of the Portal. Survey period and Portal (upstream or downstream) each significantly affected D. geminata cell density. In general, D. geminata was most abundant during the November 2009 and June 2010 surveys and at sites immediately downstream of the Portal. We found that D. geminata did not reach nuisance levels or strongly affect the periphyton community. Similarly, companion studies showed that local macroinvertebrate and fish communities were generally unaffected. A number of abiotic factors including variable flows and moderate levels of phosphorous and suspended sediment may limit blooms of D. geminata in this watershed. PMID:26148184

  16. Method and apparatus for injecting particulate media into the ground

    DOEpatents

    Dwyer, Brian P.; Dwyer, Stephen F.; Vigil, Francine S.; Stewart, Willis E.

    2004-12-28

    An improved method and apparatus for injecting particulate media into the ground for constructing underground permeable reactive barriers, which are used for environmental remediation of subsurface contaminated soil and water. A media injector sub-assembly attached to a triple wall drill string pipe sprays a mixture of active particulate media suspended in a carrier fluid radially outwards from the sub-assembly, at the same time that a mixing fluid is sprayed radially outwards. The media spray intersects the mixing spray at a relatively close distance from the point of injection, which entrains the particulate media into the mixing spray and ensures a uniform and deep dispersion of the active media in the surrounding soil. The media injector sub-assembly can optionally include channels for supplying compressed air to an attached down-the-hole hammer drive assembly for use during drilling.

  17. Underground physics and the barometric pumping effect observed for thermal neutron flux underground

    NASA Astrophysics Data System (ADS)

    Stenkin, Yu. V.; Alekseenko, V. V.; Gromushkin, D. M.; Sulakov, V. P.; Shchegolev, O. B.

    2017-05-01

    It is known that neutron background is a major problem for low-background experiments carrying out underground, such as dark matter search, double-beta decay searches and other experiments known as Underground Physics. We present here some results obtained with the en-detector of 0.75 m2, which is running for more than 4 years underground at a depth of 25 m water equivalent in Skobeltsyn Institute of Nuclear Physics, Moscow State University. Some spontaneous increases in thermal neutron flux up to a factor of 3 were observed in delayed anti-correlation with barometric pressure. The phenomenon can be explained by the radon barometric pumping effect resulting in similar effect in neutron flux being produced in (α, n)-reactions by alpha-decays of radon and its daughters in surrounding rock. This is the first demonstration of the barometric pumping effect observed in thermal neutron flux underground.

  18. Accidental contamination during hydrocarbon exploitation and the rapid transfer of heavy-mineral fines through an overlying highly karstified aquifer (Paradiso Spring, SE Sicily)

    NASA Astrophysics Data System (ADS)

    Ruggieri, Rosario; Forti, Paolo; Antoci, Maria Lucia; De Waele, Jo

    2017-03-01

    The area around Ragusa in Sicily is well known for the exploration of petroleum deposits hosted in Mesozoic carbonate rocks. These reservoirs are overlain by less permeable rocks, whereas the surface geology is characterized by outcrops of Oligo-Miocene carbonate units hosting important aquifers. Some of the karst springs of the area are used as drinking water supplies, and therefore these vulnerable aquifers should be monitored and protected adequately. In the early afternoon (14:00) of 27 May until the late evening (19:30) of 28 May 2011, during the construction of an exploitation borehole (Tresauro 2), more than 1000 m3 of drilling fluids were lost in an unknown karst void. Two days later, from 06:30 on 30 May, water flowing from Paradiso Spring, lying some 13.7 km SW of the borehole and 378 m lower, normally used as a domestic water supply, was so intensely coloured that it was unfit for drinking. Bulk chemical analyses carried out on the water have shown a composition that is very similar to that of the drilling fluids lost at the Tresauro borehole, confirming a hydrological connection. Estimations indicate that the first signs of the drilling fluids took about 59 h to flow from their injection point to the spring, corresponding to a mean velocity of ∼230 m/h. That Paradiso Spring is recharged by a well-developed underground drainage system is also confirmed by the marked flow rate changes measured at the spring, ranging from a base flow of around 10-15 l/s to flood peaks of 2-3 m3/s. Reflecting the source and nature of the initial contamination, the pollution lasted for just a few days, and the water returned to acceptable drinking-water standards relatively quickly. However, pollution related to heavy-mineral fines continues to be registered during flooding of the spring, when the aqueducts are normally shut down because of the high turbidity values. This pollution event offers an instructive example of how hydrocarbon exploitation in intensely karstified areas, where natural springs provide domestic water supplies, should be controlled effectively to prevent such disasters occurring. This pollution incident is also a useful example of how such "accidental" tracer tests can identify rapid karstic flowpaths over long distances.

  19. 30 CFR 77.1707 - First aid equipment; location; minimum requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false First aid equipment; location; minimum... OF UNDERGROUND COAL MINES Miscellaneous § 77.1707 First aid equipment; location; minimum requirements. (a) Each operator of a surface coal mine shall maintain a supply of the first aid equipment set forth...

  20. 30 CFR 947.784 - Underground mining permit applications-minimum requirements for reclamation and operation plan.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Applications—Minimum Requirements for Reclamation and Operation Plan, shall apply to any person who makes... for an underground mining permit shall also indicate how compliance will be achieved with the Washington Water Pollution Control Act, RCW 90.48. ...

  1. 40 CFR 264.18 - Location standards.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... affected surface waters or the soils of the 100- year floodplain that could result from washout. [Comment... dome formations, salt bed formations, underground mines and caves. The placement of any noncontainerized or bulk liquid hazardous waste in any salt dome formation, salt bed formation, underground mine or...

  2. 40 CFR 264.18 - Location standards.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... affected surface waters or the soils of the 100- year floodplain that could result from washout. [Comment... dome formations, salt bed formations, underground mines and caves. The placement of any noncontainerized or bulk liquid hazardous waste in any salt dome formation, salt bed formation, underground mine or...

  3. 40 CFR 264.18 - Location standards.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... affected surface waters or the soils of the 100- year floodplain that could result from washout. [Comment... dome formations, salt bed formations, underground mines and caves. The placement of any noncontainerized or bulk liquid hazardous waste in any salt dome formation, salt bed formation, underground mine or...

  4. DEVELOPMENT OF A METHODOLOGY FOR REGIONAL EVALUATION OF CONFINING BED INTEGRITY

    EPA Science Inventory

    For safe underground injection of liquid waste, confining formations must be thick, extensive, and have low permeability. Recognition of faults that extend from the potential injection zone to underground sources of drinking water is critical for evaluation of confining-bed integ...

  5. Terrestrial and Aerial Ground-Penetrating Radar in Use for the Architectural Researches: Ancient 16TH Century Water Supply and Drainage at the Monastery of EL Escorial (madrid, Spain)

    NASA Astrophysics Data System (ADS)

    Chias, P.; Abad, T.; Echeverria, E.

    2013-07-01

    Remote sensing techniques in Archaeology are increasingly essential components of the methodologies used in archaeological and architectural researches. They allow uncovering unique forgotten data which are unobtainable using traditional excavation techniques, mainly because their precise location is lost. These data are still important since they can help to prevent flood effects inside the ancient building cellars and basements, as it happened periodically in El Escorial. Wide ancient drainage galleries run more than one hundred feet downhill outside the building, ensuring that rainwater and springs were adequately drained. Nowadays their plans are lost, and the lack of documents related both to the ancient water supply and drainage systems become an impediment to solve the stains of damp on the stone masonry walls and vaults, and even other occasional flooding effects. In this case, nondestructive techniques were needed to find the ancient underground passages in order to preserve the integrity of the building and its current activities. At a first stage oblique aerial infrared images taken from a helium barrage balloon helped to find easily, quickly and cheaply the buried masonry structures. Secondly, radar pulses were particularly interesting to image the subsurface as they were valuable means of assessing the presence and amount of both soil water and buried structures. The combination of both techniques proved to be an accurate and low-cost way to find the ancient drainage systems. Finally, results were produced by means of open source software.

  6. An integrated sensing technique for smart monitoring of water pipelines

    NASA Astrophysics Data System (ADS)

    Bernini, Romeo; Catapano, Ilaria; Soldovieri, Francesco; Crocco, Lorenzo

    2014-05-01

    Lowering the rate of water leakage from the network of underground pipes is one of the requirements that "smart" cities have to comply with. In fact, losses in the water supply infrastructure have a remarkable social, environmental and economic impact, which obviously conflicts with the expected efficiency and sustainability of a smart city. As a consequence, there is a huge interest in developing prevention policies based on state-of-art sensing techniques and possibly their integration, as well as in envisaging ad hoc technical solutions designed for the application at hand. As a contribution to this framework, in this communication we present an approach aimed to pursue a thorough non-invasive monitoring of water pipelines, with both high spatial and temporal resolution. This goal is necessary to guarantee that maintenance operations are performed timely, so to reduce the extent of the leakage and its possible side effects, and precisely, so to minimize the cost and the discomfort resulting from operating on the water supply network. The proposed approach integrates two sensing techniques that work at different spatial and temporal scales. The first one is meant to provide a continuous (in both space and time) monitoring of the pipeline and exploits a distributed optic fiber sensor based on the Brillouin scattering phenomenon. This technique provides the "low" spatial resolution information (at meter scale) needed to reveal the presence of a leak and call for interventions [1]. The second technique is based on the use of Ground Penetrating Radar (GPR) and is meant to provide detailed images of area where the damage has been detected. GPR systems equipped with suitable data processing strategies [2,3] are indeed capable of providing images of the shallow underground, where the pipes would be buried, characterized by a spatial resolution in the order of a few centimeters. This capability is crucial to address in the most proper way maintenance operations, by for instance reducing as much as possible the extent of the area where excavations have to undergo or suggesting a suitable timing for the interventions. REFERENCES [1] A.Minardo, G. Persichetti, G.Testa, L. Zeni, R.Bernini, "Long term structural health monitoring by Brillouin fiber-optic sensing: a real case", Journal of Geophysical and Engineering, vol. 9, pp. S64-S69, 2012 [2] L. Crocco, G. Prisco, F. Soldovieri, N. J. Cassidy, "Early-stage leaking pipes GPR monitoring via microwave tomographic inversion", Journal of Applied Geophysics, vol. 67, pp. 270-277, 2009 [3] L. Crocco and F. Soldovieri, T. Millington and N. Cassidy, "Bistatic tomographic GPR imaging for incipient pipeline leakage evaluation", Progress In Electromagnetics Research, PIER, vol. 101, pp. 307-321, 2010

  7. Radon Dose Determination for Cave Guides in Czech Republic

    NASA Astrophysics Data System (ADS)

    Thinova, Lenka; Rovenska, Katerina

    2008-08-01

    According to recommended approach there are six (from total of twelve) open-to-public caves in Czech Republic, reaching near to an effective lung-dose of 6mSv/year. A conservative approach for estimating the potential effective lung-dose in caves (or underground) is based on two season's measurements, using solid state alpha track detector (Kodak in plastic diffusion chamber). The obtained dataset is converted into an annual effective dose, in agreement with the ICRP65 recommendation, using the "cave factor" 1.5. The value of "cave factor" which depends on the spectrum of aerosol particles, or on the proportional representation of the unattached/attached ratio (6.5 : 93.5 for residential places, 13.6 : 86.4 for caves due to lower concentration of free aerosols) and on the equilibrium factor. Thus conversion factor is 1.5 times higher in comparison with ICRP 65. Is this correct? Because a more precisely determined dose value would have a significant impact on radon remedies, or on restricting the time workers stay underground, a series of measurement was initiated in 2003 with the aim to specify input data, computation and errors in effective dose assessment in each one of the evaluated caves separately. The enhancement of personal dosimetry for underground work places includes a study of the given questions, from the following points of view in each cave: continual radon measurement; regular measurements of radon and its daughters to estimate the equilibrium factor and the presence of free 218Po; regular indoor air flow measurements to study the location of the radon supply and its transfer among individual areas of the cave; natural radioactive element content evaluation in subsoil and in water inside/outside, a study of the radon sources in the cave; determination of the free fraction from continual unattached and attached fraction measurement (grid and filter); thoron measurement. Air flow measurements provide very interesting information about the origin of "radon pockets" with very high radon concentration, and enable study of the location of the radon supply and its transfer among individual areas of the cave. Most of the results show the equilibrium factor around F = 0.2-0.7 and the unattached fraction around 2%-30%. One of the most important question remains: how accurately was the unattached fraction measured? Part of this project was to verify the influence of etched track detector position in the cave.

  8. Groundwater Regulation in the Houston-Galveston Region to Control Subsidence - Balancing Total Water Demand, Available Alternative Water Supplies, and Groundwater Withdrawal

    NASA Astrophysics Data System (ADS)

    Turco, M. J.

    2014-12-01

    In 1975, as a result of area residents and local governments becoming increasingly alarmed by the continued impact of subsidence on economic growth and quality of life in the region, the Harris-Galveston Coastal Subsidence District was created by the 64th Texas Legislature as an underground water conservation district. The primary mission of what is now the Harris-Galveston Subsidence District, is to provide for the regulation of the withdrawal of groundwater to control subsidence. Subsidence has been a concern in the Houston, TX area throughout most of recent history. Since 1906, over 10 feet of subsidence has occurred, with a broad area of 6 feet of subsidence throughout most of the Houston Area.Over its nearly forty years of existence, the District has developed substantial data sets providing the foundation for its regulatory plan. Annual water-level measurements, a network of deep extensometers, over 80 subsidence GPS monitors, and updated numerical and analytical models have been utilized. Periodically, the District utilizes U.S. Census data to predict the future magnitude and location of population and water demand. In 2013, all of these data sets were combined producing an updated regulatory plan outlining the timelines of conversion to alternative sources of water and defining the maximum percentage groundwater can contribute to a user's total water demand.The management of the groundwater resources within the District has involved significant coordination with regional ground and surface water suppliers; ongoing interaction with other state and local regulatory bodies; analysis of accurate and up to date predictions on water usage; the enforcement of real disincentives to those who rely too heavily on groundwater and a commitment to practicing and promoting water conservation.Water supplies in the region are projected to continue to be stressed in the future due to rapid population increases in the region. Future District efforts will be focused on maintaining the successes of the past while evaluating potential deeper groundwater resources and any potential subsidence resulting from future development.

  9. Geohydrology, water quality, and estimation of ground-water recharge in San Francisco, California, 1987-92

    USGS Publications Warehouse

    Phillips, S.P.; Hamlin, S.N.; Yates, E.B.

    1993-01-01

    The city of San Francisco is considering further development of local groundwater resources as a supplemental source of water for potable or nonpotable use. By the year 2010, further water demand is projected to exceed the delivery capacity of the existing supply system, which is fed by surface-water sources; thus supplies are susceptible to drought conditions and damage to conveyance lines by earthquakes. The primary purpose of this study is to describe local geohydrology and water quality and to estimate groundwater recharge in the area of the city of San Francisco. Seven groundwater basins were identified in San Francisco on the basis of geologic and geophysical data. Basins on the east side of the city are relatively thin and contain a greater percentage of fine-grained sediments than those on the west side. The relatively small capacity of the basins and greater potential for contamination from sewer sources may limit the potential for groundwater development on the east side. Basins on the west side of the city have a relatively large capacity and low density sewer network. Water-level data indicate that the southern part of the largest basin on the west side of the city (Westside basin) probably cannot accommodate additional groundwater development without adversely affecting water levels and water quality in Lake Merced; however, the remainder of the basin, which is largely undeveloped, could be developed further. A hydrologic routing model was developed for estimating groundwater recharge throughout San Francisco. The model takes into account climatic factors, land and water use, irrigation, leakage from underground pipes, rainfall runoff, evapotranspiration, and other factors associated with an urban environment. Results indicate that area recharge rates for water years 1987-88 for the 7 groundwater basins ranged from 0.32 to 0.78 feet per year. Recharge for the Westside basin was estimated at 0.51 feet per year. Average annual groundwater recharge represents the maximum annual long-term yield of the basin. Attainable yield may be less than the volume of groundwater recharge because interception of all discharge from the basin may not be feasible without inducing seawater intrusion or causing other undesirable effects.

  10. Simulation of rainfall-runoff response in mined and unmined watersheds in coal areas of West Virginia

    USGS Publications Warehouse

    Puente, Celso; Atkins, John T.

    1989-01-01

    Meteorologic and hydrologic data from five small watersheds in the coal areas of West Virginia were used to calibrate and test the U.S. Geological Survey Precipitation-Runoff Modeling System for simulating streamflow under various climatic and land-use conditions. Three of the basins--Horsecamp Run, Gilmer Run, and Collison Creek--are primarily forested and relatively undisturbed. The remaining basins--Drawdy Creek and Brier Creek-are extensively mined, both surface and underground above stream drainage level. Low-flow measurements at numerous synoptic sites in the mined basins indicate that coal mining has substantially altered the hydrologic system of each basin. The effects of mining on streamflow that were identified are (1) reduced base flow in stream segments underlain by underground mines, (2) increased base flow in streams that are downdip and stratigraphically below the elevation of the mined coal beds, and (3) interbasin transfer of ground water through underground mines. These changes probably reflect increased permeability of surface rocks caused by subsidence fractures associated with collapsed underground mines in the basin. Such fractures would increase downward percolation of precipitation, surface and subsurface flow, and ground-water flow to deeper rocks or to underground mine workings. Model simulations of the water budgets for the unmined basins during the 1972-73 water years indicate that total annual runoff averaged 60 percent of average annual precipitation; annual evapotranspiration losses averaged 40 percent of average annual precipitation. Of the total annual runoff, approximately 91 percent was surface and subsurface runoff and 9 percent was groundwater discharge. Changes in storage in the soil zone and in the subsurface and ground-water reservoirs in the basins were negligible. In contrast, water-budget simulations for the mined basins indicate significant differences in annual recharge and in total annual runoff. Model simulations of the water budget for Drawdy Creek basin indicate that total annual runoff during 1972-73 averaged only 43 percent of average annual precipitation--the lowest of all study basins; annual evapotranspiration losses averaged 49 percent, and interbasin transfer of ground-water losses averaged about 8 percent. Of the total annual runoff, approximately 74 percent was surface and subsurface flow and 26 percent was ground-water discharge. The low total annual runoff at Drawdy Creek probably reflects increased recharge of precipitation and surface and subsurface flow losses to ground water. Most of the increase in ground-water storage is, in turn, lost to a ground-water sink--namely, interbasin transfer of ground water by gravity drainage and (or) mine pumpage from underground mines that extend to adjacent basins. Hypothetical mining situations were posed for model analysis to determine the effects of increased mining on streamflow in the mined basins. Results of model simulations indicate that streamflow characteristics, the water budget, and the seasonal distribution of streamflow would be significantly modified in response to an increase in mining in the basins. Simulations indicate that (1) total annual runoff in the basins would decrease because of increased surface- and subsurface-flow losses and increased recharge of precipitation to ground water (these losses would tend to reduce medium to high flows mainly during winter and spring when losses would be greatest), (2) extreme high flows in response to intense rainstorms would be negligibly affected, regardless of the magnitude of mining in the basins, (3) ground-water discharge also would decrease during winter and spring, but the amount and duration of low flows during summer and fall would substantially increase in response to increased ground-water storage in rocks and in underground mines, and (4) the increase in ground-water storage in the basins would be depleted, mostly by increased losses to a grou

  11. 7 CFR 1955.57 - Real property containing underground storage tanks.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ...; (3) Septic tanks; (4) Pipeline facilities (including gathering lines) regulated under; (i) The...) Storm water or wastewater collection systems; (7) Flow-through process tanks; (8) Liquid traps or... 7 Agriculture 14 2014-01-01 2014-01-01 false Real property containing underground storage tanks...

  12. 7 CFR 1955.57 - Real property containing underground storage tanks.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ...; (3) Septic tanks; (4) Pipeline facilities (including gathering lines) regulated under; (i) The...) Storm water or wastewater collection systems; (7) Flow-through process tanks; (8) Liquid traps or... 7 Agriculture 14 2011-01-01 2011-01-01 false Real property containing underground storage tanks...

  13. 7 CFR 1955.57 - Real property containing underground storage tanks.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ...; (3) Septic tanks; (4) Pipeline facilities (including gathering lines) regulated under; (i) The...) Storm water or wastewater collection systems; (7) Flow-through process tanks; (8) Liquid traps or... 7 Agriculture 14 2012-01-01 2012-01-01 false Real property containing underground storage tanks...

  14. 7 CFR 1955.57 - Real property containing underground storage tanks.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ...; (3) Septic tanks; (4) Pipeline facilities (including gathering lines) regulated under; (i) The...) Storm water or wastewater collection systems; (7) Flow-through process tanks; (8) Liquid traps or... 7 Agriculture 14 2013-01-01 2013-01-01 false Real property containing underground storage tanks...

  15. Water-Searchers: A Reconfigurable and Self Sustaining Army of Subsurface Exploration Robots Searching for Water/Ice Using Multiple Sensors

    NASA Technical Reports Server (NTRS)

    Youk, G. U.; Whittaker, W. (Red); Volpe, R.

    2000-01-01

    Perhaps the most promising site for extant life on Mars today is where subsurface water has been maintained. Therefore, searching for underground water will provide a good chance to find evidence of life on Mars. The following are scientific/engineering questions that we want to answer using our approach: (1) Is there subsurface water/ice? How deep is it? How much is there? Is it frozen? (2) What kinds of underground layers exist in the Martian crust? (3) What is the density of Martian soil or regolith? Can we dig into it? Should we drill into it? (4) Can a sudden release of underground water occur if a big asteroid hits Mars? Our approach provides essential information to answer these questions. Moreover, dependence on the water content and depth in soil, not only resultant scientific conclusions but also proper digging/drilling methods, are suggested. 'How much water is in the Martian soil?' There can be several possibilities: (1) high water content that is enough to form permafrost; (2) low water content that is not enough to form permafrost; or (3) different layers with different moisture contents. 'How deep should a rover dig into soil to find water/ice?' The exact size-frequency distribution has not been measured for the soil particles. On-board sensors can provide not only the water content but also the density (or porosity) of Martian soil as a function of depth.

  16. Population exposure to trace elements in the Kilembe copper mine area, Western Uganda: A pilot study.

    PubMed

    Mwesigye, Abraham R; Young, Scott D; Bailey, Elizabeth H; Tumwebaze, Susan B

    2016-12-15

    The mining and processing of copper in Kilembe, Western Uganda, from 1956 to 1982 left over 15 Mt. of tailings containing cupriferous and cobaltiferous pyrite dumped within a mountain river valley. This pilot study was conducted to assess the nature and extent of risk to local populations from metal contamination arising from those mining activities. We determined trace element concentrations in mine tailings, soils, locally cultivated foods, house dust, drinking water and human biomarkers (toenails) using ICP-MS analysis of acid digested samples. The results showed that tailings, containing higher concentrations of Co, Cu, Ni and As compared with world average crust values had eroded and contaminated local soils. Pollution load indices revealed that 51% of agricultural soils sampled were contaminated with trace elements. Local water supplies were contaminated, with Co concentrations that exceeded Wisconsin (US) thresholds in 25% of domestic water supplies and 40% of Nyamwamba river water samples. Zinc exceeded WHO/FAO thresholds of 99.4mgkg -1 in 36% of Amaranthus vegetable samples, Cu exceeded EC thresholds of 20mgkg -1 in 19% of Amaranthus while Pb exceeded WHO thresholds of 0.3mgkg -1 in 47% of Amaranthus vegetables. In bananas, 20% of samples contained Pb concentrations that exceeded the WHO/FAO recommended threshold of 0.3mgkg -1 . However, risk assessment of local foods and water, based on hazard quotients (HQ values) revealed no potential health effects. The high external contamination of volunteers' toenails with some elements (even after a washing process) calls into question their use as a biomarker for metal exposure in human populations where feet are frequently exposed to soil dust. Any mitigation of Kilembe mine impacts should be aimed at remediation of agricultural soils, regulating the discharge of underground contaminated water but also containment of tailing erosion. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Nuclear Power - Post Fukushima

    NASA Astrophysics Data System (ADS)

    Reyes, Jose, Jr.

    2011-10-01

    The extreme events that led to the prolonged power outage at the Fukushima Daiicchi nuclear plant have highlighted the importance of assuring a means for stable long term cooling of the nuclear fuel and containment following a complete station blackout. Legislative bodies, regulatory agencies and industry are drawing lessons from those events and considering what changes, if any, are needed to nuclear power, post Fukushima. The enhanced safety of a new class of reactor designed by NuScale Power is drawing significant attention in light of the Fukushima events. During normal operation, each NuScale containment is fully immersed in a water-filled stainless steel lined concrete pool that resides underground. The pool, housed in a Seismic Category I building, is large enough to provided 30 days of core and containment cooling without adding water. After 30 days, the decay heat generations coupled with thermal radiation heat transfer is completely adequate to remove core decay heat for an unlimited period of time. These passive power systems can perform their function without requiring an external supply of water of power. An assessment of the NuScale passive systems is being performed through a comprehensive test program that includes the NuScale integral system test facility at Oregon State University

  18. Surface deformation induced by water pumping for construction of Mass Rapid Transportation in Taipei basin

    NASA Astrophysics Data System (ADS)

    Hu, J. C.; Wu, P. C.; Tung, H.; Tsai, M. C.

    2017-12-01

    In 1968, there were 2,200 wells in the Taipei Basin used for water supply to meet the requirement of high population density. The overuse of ground water lead to the land subsidence rate up to 5 cm/yr. Although the government had already begun to limit groundwater pumping since 1968, the groundwater in the Taipei Basin demonstrated temporary fluctuation induced by pumping water for large deep excavation site or engineering usage. The previous study based on precise leveling suggested that the surface deformation was highly associated with the recovery of water level. In 1989, widespread uplift dominated in Taipei basin due to the recovery of ground water Table. In this study, we use 37 high-resolution X-band COSMO-SkyMed radar images from May 2011 to April 2015 to characterize deformation pattern in the period of construction of Mass Rapid Transportation (MRT). We also use 30 wells and 380 benchmarks of precise leveling in Taipei basin to study the correlation of surface deformation and change of ground water table. The storability is roughly constant across most of the aquifer with values between 0.8 x 10-4 and 1.3 x 10-3. Moreover, the high water pumping in two major aquifers, Jignme and Wuku Foramtions, before the underground construction for MRT led to inflict surface deformation and no time delay observed for surface deformation during the water pumping. It implies that the poro-elastic effect dominates in major aquifers in Taipei basin.

  19. Heavy metals in food, house dust, and water from an e-waste recycling area in South China and the potential risk to human health.

    PubMed

    Zheng, Jing; Chen, Ke-hui; Yan, Xiao; Chen, She-Jun; Hu, Guo-Cheng; Peng, Xiao-Wu; Yuan, Jian-gang; Mai, Bi-Xian; Yang, Zhong-Yi

    2013-10-01

    Concentrations of heavy metals (Cd, Pb, Cu, Zn, and Ni) were measured in the foodstuffs, house dust, underground/drinking water, and soil from an electronic waste (e-waste) area in South China. Elevated concentrations of these potentially toxic metals were observed in the samples but not in drinking water. The health risks for metal exposure via food consumption, dust ingestion, and drinking water were evaluated for local residents. For the average residents in the e-waste area, the non-carcinogenic risks arise predominantly from rice (hazard index=3.3), vegetables (2.2), and house dust (1.9) for adults, while the risks for young children are dominated by house dust (15). Drinking water may provide a negligible contribution to risk. However, local residents who use groundwater as a water supply source are at high non-carcinogenic risk. The potential cancer risks from oral intake of Pb are 8×10(-5) and 3×10(-4) for average adults and children, and thus groundwater would have a great potential to induce cancer (5×10(-4) and 1×10(-3)) in a highly exposed population. The results also reveal that the risk from oral exposure is much higher than the risk from inhalation and dermal contact with house dust. Copyright © 2013 Elsevier Inc. All rights reserved.

  20. Contaminated Pond Water Favors Cholera Outbreak at Haibatpur Village, Purba Medinipur District, West Bengal, India

    PubMed Central

    Biswas, Dilip Kumar; Bhunia, Rama; Maji, Dipankar; Das, Palash

    2014-01-01

    Health workers reported an increased number of diarrhea cases at Haibatpur village on June 17, 2012. This outbreak was investigated with the following objectives: to confirm the existence of diarrhea outbreak, to find out the risk factors, and propose control measures. Cases were listed; spot map and epidemic curve were drawn. Attack rate was calculated by age and sex and risk factors were found out by calculating odds ratio (OR) with 95% confidence interval (CI). Rectal swabs were taken and water specimens were collected for laboratory test. Forty-one cases of patients were identified with overall attack rate (AR) was 5% (41/780). AR among men was higher 6% (25/404) than women. There was no death. V. cholerae 01 Eltor Ogawa was isolated from one (1/4) stool specimen. Spot map showed cases clustered around two ponds which were contaminated with coliform organisms. The underground water was a bit saline in nature. Using pond water for preparation of fermented rice (Panta Bhat) (OR 4.73, 95% CI 1.69–13.51), washing utensil in pond water (OR 7.31, 95% CI 1.77–42.29) were associated with cholera outbreak. Health education was done to villagers. Disinfection of two ponds with bleaching powder was done. We proposed supplying of safe drinking water and repairing defective deep tube well to village. PMID:24899903

  1. Assessment of carbon nanotubes and silver nanoparticles loaded clays as adsorbents for removal of bacterial contaminants from water sources.

    PubMed

    Hassouna, M E M; ElBably, M A; Mohammed, Asmaa N; Nasser, M A G

    2017-02-01

    This work evaluated the antimicrobial efficacy of kaolin clay and its loaded forms with carbon nanotubes (CNTs) and silver nanoparticles (AgNPs) against bacterial isolates from different water supplies (tap, underground and surface water) in addition to wastewater. A total of 160 water samples were collected from different water sources in the investigated districts. Samples were cultured for isolation and serological identification of pathogenic bacteria. AgNPs were synthesized by a typical one-step synthesis protocol, where CNTs were carried out in a reactor employing the double bias-assisted hot filament chemical vapor deposition method. Both were characterized using transmission electron microscopy, infrared and X-ray fluorescence (XRF) spectroscopy. The antimicrobial efficacy of each of natural kaolin clay, AgNPs- and CNTs-loaded clays were evaluated by their application in four concentrations (0.01, 0.03, 0.05 and 0.1 ppm) at different contact times (5 min, 15 min, 30 min and 2 h). AgNPs-loaded clays at concentrations of 0.05 and 0.1 mg/l for 2 h contact time exhibited a higher bactericidal efficacy on Escherichia coli and Salmonella spp. (70, 70, 80 and 90%, respectively) compared to CNTs-loaded clay. Concluding, the application of AgNPs-loaded clay for removal of water bacterial contaminants at a concentration of 0.1 ppm for 2 h contact times resulted in highly effective removals.

  2. Hydrological and glaciological balances on Antizana Volcano, Ecuador

    NASA Astrophysics Data System (ADS)

    Favier, V.; Cadier, E.; Coudrain, A.; Francou, B.; Maisincho, L.; Praderio, E.; Villacis, M.; Wagnon, P.

    2006-12-01

    Water supply for Quito, the capital of Ecuador, is partly fed by the water collected at the piedmont of Antizana ice covered stratovolcano. In order to assess the contribution of glaciers to the local water resources, a comparison of hydrological and glaciological datasets collected over the 1995-2005 period on Antizana Glacier 15 watershed was realized. Over the study period, Antizana glacier 15 retreated quickly, inducing an important water contribution to lower altitude discharges. However, comparison of hydrological and glaciological balances allowed observation of important missing runoffs due to underground circulations. Subsuperficial circulations were initially questioned due to the total disappearance of surface streams at the level of the frontal moraine, a surface stream being observed again downstream the moraine. Brine injections were performed upstream the moraine and in a small lake located on the moraine and restitution rates of salt were computed. Tracer experiments demonstrated a complete restitution of discharges implying that missing runoff were not involved in subsuperficial circulations but in deeper ones that may have flown through the fractured rock environment of the stratovlocano. Experiments also demonstrated that infiltrations occurred directly at the bedrock of the glaciers. Then, taking into account the weak discharges observed at the glacier front would induce computation of a strongly underestimated value of the actual water contribution from glaciers to lower altitude discharges. Finally, assessing water contribution from glaciers of Ecuador requires a comparison of glaciological and hydrological data.

  3. Application of hollow fiber liquid phase microextraction for simultaneous determination of regulated and emerging iodinated trihalomethanes in drinking water.

    PubMed

    Domínguez-Tello, A; Arias-Borrego, A; García-Barrera, T; Gómez-Ariza, J L

    2015-07-10

    Trihalomethanes (THMs) are regulated disinfection by-products (DBPs) most commonly analyzed in quality control water supply due to their harmful effects on health. However, few data exist about the content of emerging iodo-trihalomethanes (I-THMs) which are present in drinking water at very low concentrations (in the order of ngL(-1)). For this reason a two-phase hollow fiber liquid phase microextraction method for the simultaneous determination of four regulated trihalomethanes and six emerging iodo-trihalomethanes using GC-μECD and GC-MS with detection limits in the range of few ngL(-1) has been developed. A central composite design was used to optimize conditions for simultaneous extraction. The best extraction recovery was obtained with 19.2min at 27.1°C and 900rpm, without salt addition, using a supported hollow fiber membrane of 10.5cm (0.6mm id) and 1-octanol as acceptor phase. The limits of detection for the regulated THMs and I-THMs were 3-44ngL(-1) and 1-3ngL(-1), respectively. The calibration curves showed good linearity (R(2)>0.995) and good repeatibility (3-22%). The relative recoveries in water were between 96.5% and 105.2%. The method was applied for the simultaneous determination of trihalomethanes in supply water samples from seven water distribution systems (WDS) in the Huelva area, located at the southwest Spain, which use different water-treatment processes. The highest concentrations of I-THMs, particularly CHBrClI and CHCl2I, were detected in water treated with advanced treatment process using pre-ozonation, however these compounds were not detected or decreased along distribution system. In the samples of treated water with conventional treatment, using pre-oxidation by permanganate and distribution network, CHCl2I, CHBrClI, CHClI2, CHBrI2 and CHI3 were detected at very low concentrations (1-18ngL(-1)). Finally, in water samples from underground origin without oxidation treatment, in which only disinfection with sodium hypochlorite was applied, I-THMs were not detected. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Influence of groundwater extraction on river flows and the surrounding ecosystem

    NASA Astrophysics Data System (ADS)

    Belova, Anna

    2010-05-01

    Influence of groundwater extraction on river flows and the surrounding ecosystem. Change of hydro-geological conditions and the conditions of environment connected with them? One of the most adverse consequences of the large centralised operation of underground waters coastal (riverine) water fences. Such situation is predicted on the Permilovsky deposit reconnoitered for water supply of Arkhangelsk. The projected water fence was planned in a valley of the river of Vajmugi on its left coast. The predesigns spent on hydrogeodynamic of model of a deposit, show that as a result of operation of underground waters the damage to a drain of the river Vajmuga approximately equal дебиту of a water fence that leads to a considerable shallowing of the river, especially during its periods маловодности, up to a drain total disappearance on a water fence site is formed. On the average, on territories of a deposit expenses of the river concerning natural state can be reduced more than to 50 %. Reduction of a river drain will lead to considerable negative consequences in environment, including: - changes in surface runoff, reduced groundwater levels, inhibit vegetation and changes in plant communities, draining wetlands, changing soil moisture conditions, a decrease of spring runoff, damage to forestry; - earth's surface subsidence, damage to streets and roads, buildings, structures and communications, drainage wells, the development of karst processes and suffosion; - the formation of deep depressions, capturing several zones of water exchange, which could lead to mixing of water of different chemical composition and mineralization of the runoff into surface water bodies, increase the nitrogen content in groundwater; - discontinuity separating the layers and the increased vulnerability of groundwater and surface water, the action of man-made agents. The aim of this study was a preliminary study of alternative schemes of exploitation of underground water deposits, in which damage to river flow, essentially inevitable, will be minimized. The alternative scheme provides reduction of productivity of the basic water fence during the periods critical aquaticity. During these periods, for preservation of volume of water giving, the additional (compensatory) water fence is entered into operation. Settlement remoteness compensatory water fence is defined by a condition that for rather short-term period (in low flow) water fence works, its hydrodynamic influence did not reach the river and basic water fence. At the same time, during the periods high aquaticity when compensatory water fence does not work, stocks водоносного horizon on the area of its depression should be restored completely. For use of this scheme it is necessary to define the periods of an inadmissible damage to a drain during which reduction discharge of the basic water fence both use compensatory water fence, and operational loading basic water fence and compensatory water fence during the periods of their teamwork is required. Is minimum admissible expense for the given territory should be defined after the special ecological analysis. For tentative estimations 2 variants are considered: 1) in the river of Vajmuga, in a water fence alignment, the expense not below 25 % from minimum low-flow natural size all-the-year-round should remain; 2) on a water fence site in the river the expense not below 25 % from mid-annual size should remain. For both variants the periods of reduction of productivity of the basic water fence are proved and introductions in operation of the compensatory water fence. Have been calculated values of reduction of productivity of the basic water fence, its new discharge and as discharge of the compensatory water fence. It is received that discharge of the basic water fence should be reduced to 35 and 37 % for the first and second settlement variants accordingly. The quantity of knots of chinks and their arrangement stole up in the course of modelling. It is as a result received that at use of the given scheme, the drain of the river of Vajmuga does not reach values below the critical. On model it is received that at work of the compensatory water fence the funnel is formed local depression, and settlement falls of levels do not reach basic water fence and the rivers. It means that operation of the compensatory water fence does not influence a river drain and is provided drawdown capacities aquifer horizon. Result of the performed work was the proof of basic possibility of the alternative scheme of operation of underground waters on a deposit at which change of a drain of the rivers will have admissible limits and will not cause essential changes of ecological conditions of territory as a whole.

  5. Metabolic identification of germs isolated from ozonized water mixed with underground water

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fransolet, G.; Villers, G.; Goyens, A.

    Twenty bacterial strains having shown a characteristic regrowth, starting from surface water treated and ozonized and then mixed with water of underground origin have been isolated. After verification of the purity of these strains, their preliminary identification has been attempted by utilizing more than 60 tests. The identification was limited to biochemical tests based on the following types of metabolism: energetic metabolism, carbohydrate metabolism, lipid metabolism, proteic metabolism, nutritional metabolism, and utilization of special media. In support of the results, one is able to affirm that the 20 strains belong to seven families consisting of Pseudomonadaceae, Bacillaceae, the group ofmore » Coryneformes, the Azotobactericeae, Micrococcaceae, Enterobacteriaceae and Vibrionaceae.« less

  6. 40 CFR 265.191 - Assessment of existing tank system's integrity.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...); and (5) Results of a leak test, internal inspection, or other tank integrity examination such that: (i) For non-enterable underground tanks, this assessment must consist of a leak test that is capable of... water table effects, (ii) For other than non-enterable underground tanks and for ancillary equipment...

  7. 40 CFR 145.1 - Purpose and scope.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (underground injection control—UIC) of SDWA, and includes the elements which must be part of submissions to EPA... requirements of this part, the Safe Drinking Water Act and any comments received. (e) Upon approval of a State... the Administrator to delegate primary enforcement responsibility for the Underground Injection Control...

  8. 40 CFR 147.51 - State-administered program-Class I, III, IV, and V wells.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) WATER PROGRAMS (CONTINUED) STATE, TRIBAL, AND EPA-ADMINISTERED UNDERGROUND INJECTION CONTROL... elements, as submitted to EPA in the State's program application: (a) Incorporation by reference. The... (Regulations) (Rev. December 1980), as amended May 17, 1982, to add Chapter 9, Underground Injection Control...

  9. Ground-water contamination and legal controls in Michigan

    USGS Publications Warehouse

    Deutsch, Morris

    1963-01-01

    The great importance of the fresh ground-water resources of Michigan is evident because 90 percent of the rural and about 70 percent of the total population of the State exclusive of the Detroit metropolitan area are supplied from underground sources. The water-supply and public-health problems that have been caused by some cases of ground-water contamination in the State illustrate the necessity of protecting this vital resource.Manmade and natural contaminants, including many types of chemical and organic matter, have entered many of the numerous aquifers of the State. Aquifers have been contaminated by waste-laden liquids percolating from the surface or from the zone of aeration and by direct injection to the aquifer itself. Industrial and domestic wastes, septic tanks, leaking sewers, flood waters or other poor quality surface waters, mine waters, solids stored or spread at the surface, and even airborne wastes all have been sources of ground-water contamination in Michigan. In addition, naturally occurring saline waters have been induced into other aquifers by overpumping or unrestricted flow from artesian wells, possibly by dewatering operations, and by the deepening of surface stream channels. Vertical migration of saline waters through open holes from formations underlying various important aquifers also has spoiled some of the fresh ground waters in the State. In spite of the contamination that has occurred, however, the total amount of ground water that has been spoiled is only a small part of the total resource. Neither is the contamination so widespread as that of the surface streams of Michigan.Overall legal authority to control most types of ground-water contamination in the State has been assigned by the Michigan Legislature to the Water Resources Commission, although the Department of Conservation and the Health Department also exercise important water-pollution control functions. The Michigan Supreme Court, in an important case upholding the power of the Water Resources Commission to control pollution of ground water, in effect has introduced the doctrine of reasonable use into the law of the State. Excluding controls administered by the Department of Conservation on activities of the oil and gas industry, however, legal controls have not been used abate intrusion of natural saline waters into fresh-water aquifers in response to pumping and other manmade changes in the hydrologic regimen.

  10. Preliminary evaluation of the basal sandstone in Tennessee for receiving injected wastes

    USGS Publications Warehouse

    Mulderink, Dolores; Bradley, M.W.

    1986-01-01

    The EPA is authorized, under the Safe Drinking Water Act, to administer the Underground Injection Control program. This program allows for the regulation of deep-well disposal of wastes and establishes criteria to protect underground sources of drinking water from contamination. The basal sandstone in Tennessee occurs west of the Valley and Ridge province at depths of 5,000 to 9,000 ft below land surface. The basal sandstone consists of about 30 to 750 ft of Cambrian sandstone overlying the crystalline basement complex. The basal sandstone is overlain and confined by shale and carbonate rocks of the Middle and Upper Cambrian Conasauga Group. Hydrologic data for the basal sandstone, available from only three sites (four wells) in Tennessee, indicate that the basal sandstone generally has low porosity and permeability with a few zones having enough permeability to accept injected fluids. Limited water quality data indicate the basal sandstone contains water with dissolved solids concentrations exceeding 10,000 mg/L. Since the dissolved-solids concentrations exceed 10,000 mg/L, the basal sandstone is not classified as an underground source of drinking water according to EPA regulations. (Author 's abstract)

  11. Hydrogeological conceptual model determined from baseline and construction phase groundwater pressure and surface tilt-meter data at the Mizunami underground research laboratory, Japan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Takeuchi, Shinji; Takeuchi, Ryuji; Salden, Walter

    2007-07-01

    A hydrogeological conceptual model has been developed based on pressure responses observed at multilevel pressure monitoring zones in seven boreholes and surface tilt data in and around the Mizunami Underground Research Laboratory site. Pressure changes caused by some earthquakes, cross-hole hydraulic testing, and shaft excavation activities are considered. Surface tilt has been measured from the half way of the shaft excavation phase. The shaft excavation has been commenced from July 2003 with two shafts (Main shaft and Ventilation shaft). By the end of October 2005, discharging of water in the shafts has been halted at the depths of 172 mmore » and 191 m respectively to allow modifications to be made to the water treatment facility due to an excess of F and B concentration in the water. This results in the recovery of the groundwater levels and filling of the underground workings. Beginning in February 2006 pumping has been resumed and the underground workings have been re-occupied. Continuous groundwater pressure and surface tilt measurements with some numerical analysis during the shaft excavation phase show the existence of the flow barrier fault predicted from the surface-based investigation phase and hydraulic parameter around the shafts. (authors)« less

  12. Underground Coalfires as an Incentive and Challenge to THMC Modeling

    NASA Astrophysics Data System (ADS)

    Wuttke, Manfred W.; Fischer, Christian; Gusat, Dorel; Meyer, Uwe; Schmidt, Martin

    2010-05-01

    Spontaneous combustion of coal has become a world wide problem often caused by technical operations in coal mining areas. It affects human activities locally but even more important globally through the contribution to global warming by emitting substantial amounts of greenhouse gases like carbondioxid. Investigations of underground coalfires so far mainly with the aim of their mitigation have revealed a network of complex interactions between thermal, hydraulic, mechanical and chemical processes in this unique systems. Numerical modeling at the moment is only at the brink of being helpful to support the fire fighting in the field, but has already served as a tool to test the overall understanding of coal fire processes and to estimate their environmental impacts. This work aims at summarizing the status of THMC modeling of underground coalfires, mainly from the perspective of the Sino-German Coalfire Project, and gives an overview of the open questions and challenges to rise to if one is up to comprehensive and meaningful modeling work. The main topics are: The fluid transport through fractured porous media is driven by chemical processes at high temperatures causing high pressure gradients. Transport processes occur on different timescales. Thermal and mechanical stresses cause fracturing in the porous media on a huge range of scales, thus constantly changing the pathways for oxygen supply and exhaust gas removal. To investigate any extinction process one has to consider multi phase transport with phase changes (evaporation and condensation of water, transport of mud and cementation, etc.). To interpret surface signatures like temperature anomalies one has to link the underground processes to atmospheric heat transport including radiation. Coal fires are highly individual, threedimensional systems in general without any symmetry. Other problems in geoscience and geoengineering (like nuclear waste deposition, geothermal energy utilization, carbon dioxide sequestration) require a comparably complex approach to modeling. Although the details make it impossible to apply a single code implementation to all systems, their investigations go in similar ways. There is a need for modular code systems with open access for the various communities to maximize the shared synergistic effects.

  13. 30 CFR 77.901 - Protection of low- and medium-voltage three-phase circuits.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Protection of low- and medium-voltage three... WORK AREAS OF UNDERGROUND COAL MINES Low- and Medium-Voltage Alternating Current Circuits § 77.901 Protection of low- and medium-voltage three-phase circuits. (a) Low- and medium-voltage circuits supplying...

  14. 30 CFR 77.901 - Protection of low- and medium-voltage three-phase circuits.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Protection of low- and medium-voltage three... WORK AREAS OF UNDERGROUND COAL MINES Low- and Medium-Voltage Alternating Current Circuits § 77.901 Protection of low- and medium-voltage three-phase circuits. (a) Low- and medium-voltage circuits supplying...

  15. 30 CFR 77.901 - Protection of low- and medium-voltage three-phase circuits.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Protection of low- and medium-voltage three... WORK AREAS OF UNDERGROUND COAL MINES Low- and Medium-Voltage Alternating Current Circuits § 77.901 Protection of low- and medium-voltage three-phase circuits. (a) Low- and medium-voltage circuits supplying...

  16. 30 CFR 77.901 - Protection of low- and medium-voltage three-phase circuits.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Protection of low- and medium-voltage three... WORK AREAS OF UNDERGROUND COAL MINES Low- and Medium-Voltage Alternating Current Circuits § 77.901 Protection of low- and medium-voltage three-phase circuits. (a) Low- and medium-voltage circuits supplying...

  17. 30 CFR 77.901 - Protection of low- and medium-voltage three-phase circuits.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Protection of low- and medium-voltage three... WORK AREAS OF UNDERGROUND COAL MINES Low- and Medium-Voltage Alternating Current Circuits § 77.901 Protection of low- and medium-voltage three-phase circuits. (a) Low- and medium-voltage circuits supplying...

  18. 30 CFR 75.802 - Protection of high-voltage circuits extending underground.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... serve as a grounding conductor for the frames of all high-voltage equipment supplied power from that... stationary electric equipment if: (1) Such circuits are either steel armored or installed in grounded, rigid steel conduit throughout their entire length; or, (2) The voltage of such circuits is nominally 2,400...

  19. 30 CFR 75.802 - Protection of high-voltage circuits extending underground.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... serve as a grounding conductor for the frames of all high-voltage equipment supplied power from that... stationary electric equipment if: (1) Such circuits are either steel armored or installed in grounded, rigid steel conduit throughout their entire length; or, (2) The voltage of such circuits is nominally 2,400...

  20. 30 CFR 75.1713-7 - First-aid equipment; location; minimum requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false First-aid equipment; location; minimum... § 75.1713-7 First-aid equipment; location; minimum requirements. (a) Each operator of an underground coal mine shall maintain a supply of the first-aid equipment set forth in paragraph (b) of this § 75...

  1. Use of geophysical methods in man-made hazard management strategies. Case study from Ploiesti city, Romania

    NASA Astrophysics Data System (ADS)

    Chitea, F.; Anghelache, M. A.; Ioane, D.

    2010-05-01

    Identification of damages/changes that are affecting the underground water quality due to the effect of anthropogenic activities is often done after environmental problems have become evident, water potability being strongly affected. In this paper we will discuss the necessity of implementing non-invasive and non-destructive investigation tools in different parts of the management plan for urban areas affected or with high risk of being affected by man-made hazards. Geophysical investigations represent nowadays a useful tool in environmental problems that affect soil and underground water in urban areas, as useful information can be obtained regarding the following aspects: - detection of affected areas, especially when the effect or hazard sources are not visible at the surface - zonation of the area (severely affected zone or less affected) - investigation of the area (details on affected surface and affected soil depth) - location of "hidden" sources (illegal waste dump sites, petroleum transport or transfer pipes, etc) - estimation of soil and underground damages by monitoring petrophysical markers - risk evaluation (estimations on the direction and speed of environmental problems development, estimations of amplifying negative effects) - recovery from the man-made hazard of a certain area (monitoring information can give information about natural attenuation of the environmental problems or efficacy of resilience program) - preparedness for man-made hazards (prediction). Functionality of the above mentioned plans of geophysical applicability in identifying and characterizing the effect of anthropogenic hazards which affect soil and underground water quality has been tested in Ploiesti city, Romania. In this urban area, as well as in surrounding villages, water potability is severely affected because of the oil-products contamination caused by the refinery facilities developed in the area. Oil-contamination is a major problem environmental problem, due to the fact that affected area is continuously expanding as a consequence of contaminant transport by the underground water. Hydrogeologically the research area is located in the alluvium of one of the main hydrostructures of Romania, which holds important water resources. Preliminary investigations made in the Ploiesti city area, has shown the high vulnerability of the aquifer to pollution and it was detected a highly contaminated area. By detailed investigations made using geophysical investigations in the test-zone, it was possible the detection of the presence of the particular type of pollutants and a map with area zonation has been produced. Appliance of geophysical investigations in environmental strategies concerning underground water pollution should be added to the ones obtained by direct investigations for risk evaluation and remediation strategies in cases of man made hazards. Acknowledgements: The research was performed with financial support from MENER (project nr. 725/ 2006) and CNCSIS-UEFISCU (project nr. 244/2007)

  2. Stability numerical analysis of soil cave in karst area to drawdown of underground water level

    NASA Astrophysics Data System (ADS)

    Mo, Yizheng; Xiao, Rencheng; Deng, Zongwei

    2018-05-01

    With the underground water level falling, the reliable estimates of the stability and deformation characteristics of soil caves in karst region area are required for analysis used for engineering design. Aimed at this goal, combined with practical engineering and field geotechnical test, detail analysis on vertical maximum displacement of top, vertical maximum displacement of surface, maximum principal stress and maximum shear stress were conducted by finite element software, with an emphasis on two varying factors: the size and the depth of soil cave. The calculations on the soil cave show that, its stability of soil cave is affected by both the size and depth, and only when extending a certain limit, the collapse occurred along with the falling of underground water; Additionally, its maximum shear stress is in arch toes, and its deformation curve trend of maximum displacement is similar to the maximum shear stress, which further verified that the collapse of soil cave was mainly due to shear-failure.

  3. A mobile detector for measurements of the atmospheric muon flux

    NASA Astrophysics Data System (ADS)

    Mitrica, B.; Brancus, I. M.; Margineanu, R.; Petcu, M.; Dima, M.; Sima, O.; Haungs, A.; Rebel, H.; Petre, M.; Toma, G.; Saftoiu, A.; Apostu, A.

    2011-04-01

    Measurements of the underground atmospheric muon flux are important in order to determine accurately the overburden in mwe (meter water equivalent) of an underground laboratory for appreciating which kind of experiments are feasible for that location. Slanic- Prohava is one of the 7 possible locations for the European large underground experiment LAGUNA (Large Apparatus studying Grand Unification and Neutrino Astrophysics). A mobile device consisting of 2 scintillator plates (≍0.9 m2, each) one above the other and measuring in coincidence, was set-up for determining the muon flux. The detector it is installed on a van which facilitates measurements on different positions at the surface or in the underground and it is in operation since autumn 2009. The measurements of muon fluxes presented in this contribution have been performed in the underground salt mine Slanic-Prahova, Romania, where IFIN-HH has built a low radiation level laboratory, and at the surface on different sites of Romania, at different elevations from 0 m a.s.l up to 655 m a.s.l. Based on our measurements we can say that Slanic site is a feasible location for LAGUNA in Unirea salt mine at a water equivalent depth of 600 mwe. The results have been compared with Monte-Carlo simulations performed with the simulation codes CORSIKA and MUSIC.

  4. Ground ice formed after underground thermo-erosion of the permafrost in Alaska

    NASA Astrophysics Data System (ADS)

    Fortier, D.; Kanevskiy, M.; Yuri, S.

    2007-12-01

    Cryostratigraphic studies realized in the CRREL permafrost tunnel (¡Ö 64 57 N, 147 37 W) located near Fairbanks, Alaska revealed the presence of multi-directional reticulate ice veins and massive ice bodies in the permafrost. We propose that this reticulate-chaotic cryostructure and the massive ice bodies were formed by inward closed-system freezing of pools of water and saturated sediments trapped in underground tunnels cut in the permafrost by thermo-erosion. The massive ice and the multi-directional reticulate ice veins were likely formed after the cessation of the underground flow, either by tunnel blockage or collapse, or cessation of runoff infiltration in the permafrost. The observed tunnels were slightly inclined and could often be traced for several meters. The properties of the sediments filling these tunnels differed from the enclosing original syngenetic Pleistocene permafrost. The latter was made of ice-rich loess with abundant rootlets and was characterized by a well developed micro-lenticular cryostructure whereas the tunnels were filled with massive ice and/or organic- poor, stratified silts, sands and gravels sediments. The water content of the original syngenetic loess was about twice the water content of the sediments in the underground tunnels. The contact between the original syngenetic loess and the sediments in the tunnels was manifestly discordant and outlined by erosion lag. Release of latent heat from the poll of water and water of the saturated sediments created thaw unconformities at the tunnel boundary. Similar types of massive ice and reticulate-chaotic cryostructures were observed in Holocene to Pleistocene permafrost exposures along the Beaufort Sea Coast, on the Seward Peninsula, on the North Slope and in the Alaskan interior. The massive ice bodies and reticulate-chaotic cryostructures were always associated with, or incorporated within, ice wedges that showed signs of thermo-erosion. This indicates that the process of underground thermo-erosion has occurred widely in Alaska. On Bylot Island in the Canadian Arctic archipelago, Fortier et al. (2007) observed that extensive gullying of the permafrost resulted from the process of underground thermo-erosion. More studies are needed to determine the role of this process in the evolution of ice-wedge polygons landscape in Alaska. Fortier, D., Allard, M., Shur, Y. 2007. Observation of rapid drainage system development by thermal erosion of ice wedges on Bylot Island, Canadian Arctic Archipelago. Permafrost and Periglacial Processes 18 (3): 229-243.

  5. Underground water in Sanpete and central Sevier valleys, Utah

    USGS Publications Warehouse

    Richardson, George Burr

    1907-01-01

    Sanpete and central Sevier valleys are situated at the border of the Basin Range and Plateau provinces in south-central Utah. They are bounded on the east by the Wasatch and Sevier plateaus and on the west by the Gunnison Plateau and the Valley and Pavant ranges, and are drained by Sevier River, which empties into Sevier Lake in the Great Basin. (See fig. 1, p. 6.)These valleys rank with the richest parts of the State. They were occupied a few years after the Mormon pioneers founded Salt Lake City, in 1847, when settlements, which soon became thriving farming communities, were established where water for irrigation was most available. A variety of crops, especially wheat, are successfully grown, and the valleys are popularly known as the "granary of Utah." Sheep raising is also an important industry, the adjacent highlands being used for summer pastures. The climate is arid, and there is a striking contrast between those areas which in their natural state are covered with sagebrush and grease wood and the fruitful cultivated tracts. (See PI. I, A and B.) Trees are normally absent in the valleys, but they flourish to a limited extent on the adjacent highlands, where there are thin growths of quaking aspen, scrub oak, and stunted conifers. Irrigation is necessary for the production of crops. Canal systems are maintained by San Pitch Creek and Sevier River, and the mountain streams are tapped by ditches near the mouths of the canyons, but this supply is insufficient and attention is being turned to the subterranean store.This report is a preliminary statement of the general conditions of occurrence of underground water in Sanpete and central Sevier valleys. The field work was carried on in cooperation with Sanpete and Sevier counties through the State engineer, Mr. Caleb Tanner, who detailed Mr. C. S. Jarvis to collect the data embodied in the list of springs and wells on pages 51-60.

  6. Double-peaked breakthrough curves as a consequence of solute transport through underground lakes: a case study of the Furfooz karst system, Belgium

    NASA Astrophysics Data System (ADS)

    Dewaide, Lorraine; Collon, Pauline; Poulain, Amaël; Rochez, Gaëtan; Hallet, Vincent

    2018-03-01

    The existence of double-peaked breakthrough curves (BTC), which are the result of the transport of a dye tracer through underground lakes, is reported. Investigations were undertaken on the Furfooz karst system in southern Belgium. In this system, the River Lesse sinks partially into a swallow hole. The water follows a solitary conduit leading to an underground lake that is directly connected to a second underground lake. Double-peaked BTCs were detected in the resurgent water, downstream of this second lake. The report first describes field data (tracer tests in various hydrologic conditions) which point towards the double peak being linked to a nonlinear process that originates within the lakes. Complementary investigations within the lakes show a complex behavior of the dye tracer related to a specific hydrodynamic feature that leads to the separation of the solute plume. A conceptual model of the solute transport within the lakes is proposed. This model emphasizes the physical effect of the lakes on the dye flow-through process.

  7. A 4 GHz phase locked loop design in 65 nm CMOS for the Jiangmen Underground Neutrino Observatory detector

    NASA Astrophysics Data System (ADS)

    Parkalian, N.; Robens, M.; Grewing, C.; Christ, V.; Kruth, A.; Liebau, D.; Muralidharan, P.; Nielinger, D.; Roth, C.; Yegin, U.; Zambanini, A.; van Waasen, S.

    2018-02-01

    This paper presents a 4 GHz phase locked loop (PLL), which is implemented in a 65 nm standard CMOS process to provide low noise and high frequency sampling clocks for readout electronics to be used in the Jiangmen Underground Neutrino Observatory (JUNO) experiment. Based on the application requirements the target of the design is to find the best compromise between power consumption, area and phase noise for a highly reliable topology. The design implements a novel method for the charge pump that suppresses current mismatch when the PLL is locked. This reduces static phase offset at the inputs of the phase-frequency detector (PFD) that otherwise would introduce spurs at the PLL output. In addition, a technique of amplitude regulation for the voltage controlled oscillator (VCO) is presented to provide low noise and reliable operation. The combination of thin and thick oxide varactor transistors ensures optimum tuning range and linearity over process as well as temperature changes for the VCO without additional calibration steps. The current mismatch at the output of the charge pump for the control voltage at about half the 1 V supply voltage is below 0.3% and static phase offset down to 0.25% is reached. The total PLL consumes 18.5 mW power at 1.8 V supply for the VCO and 1 V supply for the other parts.

  8. Analysis of Economic Efficiency of Production of Low-Concentrated Sodium Hypochlorite by Direct Electrolysis of Natural Waters

    NASA Astrophysics Data System (ADS)

    Fesenko, L. N.; Pchelnikov, I. V.; Fedotov, R. V.

    2017-11-01

    The study presents the economic efficiency of direct electrolysis of natural waters in comparison with the waters artificially prepared by electrolysis of the 3% sodium salt solution. The study used sea water (Black sea water); mineral water (underground water of the Melikhovskaya station, “Ognennaya” hole); brackish water (underground water from the Grushevskaya station of the Aksai district); 3% solution of sodium salt. As a result, the dependences characterizing the direct electrolysis of natural waters with different mineralization, economic, and energy parties are shown. The rational area of the electrolysis for each of the investigated solution is determined. The cost of a kilogram of active chlorine obtained by the direct water electrolysis: Black sea from 17.2 to 18.3 RUB/kg; the Melikhovskaya station “Ognennaya” hole - 14.3 to 15.0 Rubles/kg; 3% solution of NaCl - 30 Rubles./kg; Grushevskogo St. - 63,0-73,0 Rubles/kg.

  9. Data for factor analysis of hydro-geochemical characteristics of groundwater resources in Iranshahr.

    PubMed

    Biglari, Hamed; Saeidi, Mehdi; Karimyan, Kamaleddin; Narooie, Mohammad Reza; Sharafi, Hooshmand

    2018-08-01

    Detection of Hydrogeological and Hydro-geochemical changes affecting the quality of aquifer water is very important. The aim of this study was to determine the factor analysis of the hydro-geochemical characteristics of Iranshahr underground water resources during the warm and cool seasons. In this study, 248 samples (two-time repetitions) of ground water resources were provided at first by cluster-random sampling method during 2017 in the villages of Iranshahr city. After transferring the samples to the laboratory, concentrations of 13 important chemical parameters in those samples were determined according to o water and wastewater standard methods. The results of this study indicated that 45.45% and 55.55% of the correlation between parameters has had a significant decrease and increase, respectively with the transition from warm seasons to cold seasons. According to the factor analysis method, three factors of land hydro-geochemical processes, supplying resources by surface water and sewage as well as human activities have been identified as influential on the chemical composition of these resources.The highest growth rate of 0.37 was observed between phosphate and nitrate ions while the lowest trend of - 0.33 was seen between fluoride ion and calcium as well as chloride ions. Also, a significant increase in the correlation between magnesium ion and nitrate ion from warm seasons to cold seasons indicates the high seasonal impact of the relation between these two parameters.

  10. Theory of aquifer tests

    USGS Publications Warehouse

    Ferris, J.G.; Knowles, D.B.; Brown, R.H.; Stallman, R.H.

    1962-01-01

    The development of water supplies from wells was placed on a rational basis with Darcy's development of the law governing the movement of fluids through sands and with Dupuit's application of that law to the problem of radial flow toward a pumped well. As field experience increased, confidence in the applicability of quantitative methods was gained and interest in developing solutions for more complex hydrologic problems was stimulated. An important milestone was Theis' development in 1935 of a solution for the nonsteady flow of ground water, which enabled hydrologists for the first time to predict future changes in ground-water levels resulting from pumping or recharging of wells. In the quarter century since, quantitative ground-water hydrology has been enlarging so rapidly as to discourage the preparation of comprehensive textbooks. This report surveys developments in fluid mechanics that apply to groundwater hydrology. It emphasizes concepts and principles, and the delineation of limits of applicability of mathematical models for analysis of flow systems in the field. It stresses the importance of the geologic variable and its role in governing the flow regimen. The report discusses the origin, occurrence, and motion of underground water in relation to the development of terminology and analytic expressions for selected flow systems. It describes the underlying assumptions necessary for mathematical treatment of these flow systems, with particular reference to the way in which the assumptions limit the validity of the treatment.

  11. Applied technology for mine waste water decontamination in the uranium ores extraction from Romania

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bejenaru, C.; Filip, G.; Vacariu, V.T.

    1996-12-31

    The exploitation of uranium ores in Romania is carried out in underground mines. In all exploited uranium deposits, mine waste waters results and will still result after the closure of uranium ore extraction activity. The mine waters are radioactively contaminated with uranium and its decay products being a hazard both for underground waters as for the environment. This paper present the results of research work carried out by authors for uranium elimination from waste waters as the problems involved during the exploitation process of the existent equipment as its maintenance in good experimental conditions. The main waste water characteristics aremore » discussed: solids as suspension, uranium, radium, mineral salts, pH, etc. The moist suitable way to eliminate uranium from mine waste waters is the ion exchange process based on ion exchangers in fluidized bed. A flowsheet is given with main advantages resulted.« less

  12. Drought in the Klamath River Basin

    NASA Technical Reports Server (NTRS)

    2002-01-01

    For more than 100 years groups in the western United States have fought over water. During the 1880s, sheep ranchers and cattle ranchers argued over drinking water for their livestock on the high plains. In 1913, the city of Los Angeles began to draw water away from small agricultural communities in the Owen Valley, leaving a dusty dry lake bed. In the late 1950s, construction of the Glen Canyon Dam catalyzed the American environmental movement. Today, farmers are fighting fishermen, environmentalists, and Native American tribes over the water in the Upper Klamath River Basin. A below-average winter snowpack and low rainfall throughout the year have caused an extreme drought in the area along the California/Oregon border. In April 2001 a U.S. District Court stopped water deliveries to farms in the Klamath Irrigation District to preserve adequate water levels in Upper Klamath Lake to protect two endangered species of Mullet fish (called suckers). Water was also reserved for the threatened Coho Salmon which need enough water to swim downstream from their spawning grounds to the ocean. In addition, several Native American tribes have rights to Klamath River water. Further complicating the situation are a handful of wildlife refuges which usually receive enough irrigation wastewater to support upwards of a million migratory birds and 900 Bald Eagles. This year, however, several of the refuges may not have enough water for the birds which begin arriving in early fall. The severity of this year's drought is underscored by the town of Bonanza, Oregon. Famous for its natural springs, and entirely dependent on wells for drinking water, the town's water supply is now contaminated with pesticides, fertilizer, and manure. The water quality is so bad it's not even safe to bathe in, much less drink. The problem stems from a very low water table. The drop in underground water levels is caused directly by the drought, and indirectly from the increased irrigation from underground aquifers to compensate for the lack of water from Upper Klamath Lake. As the water table drops, clean water stops flowing from the springs and wells, and dirty water from fields flows into the water beneath Bonanza. Area farmers, many of them entirely dependent on irrigation, immediately launched protests when the court's decision to stop irrigation flows was announced, leading to national media coverage. On July 24 the Department of the Interior approved the release of some irrigation water from Upper Klamath Lake, but the flow lasted only until August 23. The water was enough to save some fields growing winter feed for livestock, but some other crops were unsalvageable, and water didn't reach every farmer who needed it. The Klamath Project dates back to 1903, when the Reclamation Service (now the Bureau of Reclamation, a branch of the U.S. Department of the Interior) investigated the possibility of converting rangeland, wetlands, and natural lakes into irrigated farmland. Construction began in 1906, the first water deliveries were made in 1907, and the project was completed in 1924. The Bureau of Reclamation supplies water to the farmers at the cost of delivery, without charging for the water. Fodder, barley, oats, potatoes, and wheat are the principal crops on the 225,000 acres of irrigated land. In addition, the irrigation dams control floodwaters, and the Link River Dam supplies hydroelectric power. The images above show the northeast portion of the Klamath Basin in 2000 (top) and 2001 (lower). These true-color images were acquired by the Enhanced Thematic Mapper Plus sensor aboard the Landsat 7 satellite, launched by NASA and operated by the U.S. Geological Survey. Upper Klamath Lake, with its endangered sucker fish, is at the upper left, with the town of Klamath falls immediately below it. Bonanza is to the right of Klamath Falls. Tule Lake, which has been partially converted to farmland, is at the lower right and is surrounded by the Tule Lake National Wildlife Refuge. To the left of Tule Lake are the remains of Lower Klamath Lake and the marshes of the Lower Klamath National Wildlife Refuge. Farms left dry by the water shortage appear brown in this year's image. Most of the farms without irrigation water are between Upper Klamath Lake and Tule Lake. The land immediately surrounding Tule Lake did receive irrigation water this year, and as a result is greener than the fields to the north. Some farms rely on wells and not Klamath Project water, and many of these remained green, as well. Images courtesy USGS EROS Data Center and the Landsat 7 Science Team

  13. Effects of coal mine subsidence in the Sheridan, Wyoming, area

    USGS Publications Warehouse

    Dunrud, C. Richard; Osterwald, Frank W.

    1980-01-01

    Analyses of the surface effects of past underground coal mining in the Sheridan, Wyoming, area suggest that underground mining of strippable coal deposits may damage the environment more over long periods of time than would modern surface mining, provided proper restoration procedures are followed after surface mining. Subsidence depressions and pits are a continuing hazard to the environment and to man's activities in the Sheridan, Wyo., area above abandoned underground mines in weak overburden less than about 60 m thick and where the overburden is less than about 10-15 times the thickness of coal mined. In addition, fires commonly start by spontaneous ignition when water and air enter the abandoned mine workings via subsidence cracks and pits. The fires can then spread to unmined coal as they create more cavities, more subsidence, and more cracks and pits through which air can circulate. In modern surface mining operations the total land surface underlain by minable coal is removed to expose the coal. The coal is removed, the overburden and topsoil are replaced, and the land is regraded and revegetated. The land, although disturbed, can be more easily restored and put back into use than can land underlain by abandoned underground mine workings in areas where the overburden is less than about 60 m thick or less than about 10-15 times the thickness of coal mined. The resource recovery of modern surface mining commonly is much greater than that of underground mining procedures. Although present-day underground mining technology is advanced as compared to that of 25-80 years ago, subsidence resulting from underground mining of thick coal beds beneath overburden less than about 60 m thick can still cause greater damage to surface drainage, ground water, and vegetation than can properly designed surface mining operations. This report discusses (11 the geology and surface and underground effects of former large-scale underground coal mining in a 50-km 2 area 5-20 km north of Sheridan, Wyo., (2) a ground and aerial reconnaissance study of a 5-km^2 coal mining area 8-10 km west of Sheridan, and (31 some environmental consequences and problems caused by coal mining.

  14. Occurrence and temporal variability of methyl tert-butyl ether (MTBE) and other volatile organic compounds in select sources of drinking water : results of the focused survey

    USGS Publications Warehouse

    Delzer, Gregory C.; Ivahnenko, Tamara

    2003-01-01

    The large-scale use of the gasoline oxygenate methyl tert-butyl ether (MTBE), and its high solubility, low soil adsorption, and low biodegradability, has resulted in its detection in ground water and surface water in many places throughout the United States. Studies by numerous researchers, as well as many State and local environmental agencies, have discovered high levels of MTBE in soils and ground water at leaking underground gasoline-storage-tank sites and frequent occurrence of low to intermediate levels of MTBE in reservoirs used for both public water supply and recreational boating.In response to these findings, the American Water Works Association Research Foundation sponsored an investigation of MTBE and other volatile organic compounds (VOCs) in the Nation?s sources of drinking water. The goal of the investigation was to provide additional information on the frequency of occurrence, concentration, and temporal variability of MTBE and other VOCs in source water used by community water systems (CWSs). The investigation was completed in two stages: (1) reviews of available literature and (2) the collection of new data. Two surveys were associated with the collection of new data. The first, termed the Random Survey, employed a statistically stratified design for sampling source water from 954 randomly selected CWSs. The second, which is the focus of this report, is termed the Focused Survey, which included samples collected from 134 CWS source waters, including ground water, reservoirs, lakes, rivers, and streams, that were suspected or known to contain MTBE. The general intent of the Focused Survey was to compare results with the Random Survey and provide an improved understanding of the occurrence, concentration, temporal variability, and anthropogenic factors associated with frequently detected VOCs. Each sample collected was analyzed for 66 VOCs, including MTBE and three other ether gasoline oxygenates (hereafter termed gasoline oxygenates). As part of the Focused Survey, 451 source-water samples and 744 field quality-control (QC) samples were collected from 78 ground-water, 39 reservoir and (or) lake, and 17 river and (or) stream source waters at fixed intervals for a period of 1 year.Using a common assessment level of 0.2 ?g/L (micrograms per liter) (2.0 ?g/L for methyl ethyl ketone), 37 of the 66 VOCs analyzed were detected in both surveys. However, VOCs, especially MTBE and other gasoline oxygenates, were detected more frequently in the Focused Survey than in the Random Survey. MTBE was detected in 55.5 percent of the CWSs sampled in the Focused Survey and in 8.7 percent of those sampled in the Random Survey. Little difference in occurrence, however, was observed for trihalomethanes (THMs), which were detected in 16.4 and 14.8 percent of Focused Survey and The large-scale use of the gasoline oxygenate methyl tert-butyl ether (MTBE), and its high solubility, low soil adsorption, and low biodegradability, has resulted in its detection in ground water and surface water in many places throughout the United States. Studies by numerous researchers, as well as many State and local environmental agencies, have discovered high levels of MTBE in soils and ground water at leaking underground gasoline-storage-tank sites and frequent occurrence of low to intermediate levels of MTBE in reservoirs used for both public water supply and recreational boating.In response to these findings, the American Water Works Association Research Foundation sponsored an investigation of MTBE and other volatile organic compounds (VOCs) in the Nation?s sources of drinking water. The goal of the investigation was to provide additional information on the frequency of occurrence, concentration, and temporal variability of MTBE and other VOCs in source water used by community water systems (CWSs). The investigation was completed in two stages: (1) reviews of available literature and (2) the collection of new data. Two surveys wer

  15. Role of Underground Erosion of Ice Wedges in Drainage System Formation

    NASA Astrophysics Data System (ADS)

    Fortier, D.; Shur, Y.; Allard, M.

    2006-12-01

    Natural rapid development of a new drainage system was studied on Bylot Island, Nunavut, Canada (73° 10' N, 80° 05' W). Formation of sinkholes eroded in ice wedges evolved in underground tunnels cut in ice- rich permafrost (average water content of 130%). The tunnel scouring process occurred mainly during snowmelt runoff and was manifestly a function of the intensity of the water flow entering the permafrost. When surface water flowed into the ground, the active layer was still frozen and the temperature of the permafrost at a depth of 3 m was below -15°C. Forced convection with a high convective heat transfer coefficient provided high rate of tunnels enlargement. The erosion rate was much higher in the beginning of runoff, when its velocity and discharge were high but water and soil were colder, than later in the summer, when water and soil temperature was much warmer but water discharge and velocity much lower. Widening of tunnels was followed by creep subsidence and collapse of their roofs and development of gullies. The drainage has generally developed along the elevation gradient. Some deviation from it was caused by temporal obstruction to water flow from collapsed blocks of soil. In such cases water found the way through connecting ice wedges. Retrogressive erosion escarpments exposed to flowing water retreated at a maximum rate of 1 to 5 meters per day for a total of 15 to 50 m during the summer. Escarpment exposed to atmospheric heat and solar radiation receded at a rate of 0.6 and 10 m per summer with a mean of 4 meters during the first year of exposition. Such slopes were nearly stabilized after 4 years with retreat rate of only a few centimeters per year in 2002. In four years, the underground tunnel network evolved into a continuous system of gullies over 750 m long and covering an area of about 20,000 m2. The main factors affecting rapid development of the new drainage system are the rate and volume of runoff, the presence of ice wedges, their dimension and orientation, and the ice content of the sediments. Ice wedge volume growth over the years increases their susceptibility to underground thermo-erosion. Climate warming scenarios predict increase in summer and winter precipitation in the Arctic and, as a result, underground thermo-erosion is likely to be more frequent and remodeling of the drainage system more aggressive. More work remains to be done to understand the changes that have occurred in the watershed to trigger such significant readjustments to the drainage system.

  16. Numerical study on criteria for design and operation of water curtain system in underground oil storage cavern using site descriptive fracture networks

    NASA Astrophysics Data System (ADS)

    Moon, Jiwon; Yeo, In Wook

    2013-04-01

    Underground unlined caverns have been constructed in fractured rocks to stockpile oil and petroleum products, where they are hydraulically contained by natural groundwater pressure. However, for the case that natural groundwater pressure is not maintained at the required level, water curtain boreholes, through which water is injected, are often constructed above the cavern as engineering barrier to secure water pressure enough to overwhelm the operational pressure of the cavern. For secure containment of oil and petroleum products inside the cavern, it is essential to keep water pressure around the cavern higher than operational pressure of the cavern using either natural groundwater pressure or engineering barrier. In the Republic of Korea, a number of underground stockpile bases are being operated by Korea National Oil Corporation (KNOC) and private companies, most of which have water curtain system. The criterion that KNOC adopts for water curtain system design and operation such as the vertical distance from the cavern and operational injection rate is based on the Åberg hypothesis that the vertical hydraulic gradient should be larger than one. The criterion has been used for maintaining oil storage cavern without its thorough review. In this study, systematic numerical works have been done for reviewing the Åberg criterion. As groundwater predominantly takes places through fractures in underground caverns, discrete fracture modeling approach is essential for this study. Fracture data, obtained from boreholes drilled at the stage of site investigation at the Yeosu stockpile base in Korea, were statistically analyzed in terms of orientation and intensity, which were used to generate the site descriptive three dimensional fracture networks. Then, groundwater flow modeling has been carried out for the fracture networks. Constant head boundaries were applied along the circumference of the cavern and water curtain boreholes. Main flow channel and hydraulic connectivity between water curtain boreholes and the caverns have been identified, along which hydraulic heads are monitored to find out whether the required hydraulic pressure is maintained around the cavern. The flow modeling has been repeatedly carried out at different constant head boundary conditions to create the criterion for the optimal operation of water curtain system.

  17. Water underground

    NASA Astrophysics Data System (ADS)

    de Graaf, Inge

    2015-04-01

    The world's largest assessable source of freshwater is hidden underground, but we do not know what is happening to it yet. In many places of the world groundwater is abstracted at unsustainable rates: more water is used than being recharged, leading to decreasing river discharges and declining groundwater levels. It is predicted that for many regions of the world unsustainable water use will increase, due to increasing human water use under changing climate. It would not be long before shortage causes widespread droughts and the first water war begins. Improving our knowledge about our hidden water is the first step to stop this. The world largest aquifers are mapped, but these maps do not mention how much water they contain or how fast water levels decline. If we can add a third dimension to the aquifer maps, so a thickness, and add geohydrological information we can estimate how much water is stored. Also data on groundwater age and how fast it is refilled is needed to predict the impact of human water use and climate change on the groundwater resource.

  18. The Extreme Results of Climate Changes in Turkey: Sinkholes

    NASA Astrophysics Data System (ADS)

    Onursal Denli, G.; Denli, H. H.

    2016-12-01

    During the past few years a strange phenomenon has been increasingly observed all over the world. Residents of various places around the world have been taken aback to find sinkholes suddenly come up in their locality - sometimes involving fatalities. A sinkhole is a depression or hole in the ground caused by some form of collapse of the surface layer. The ground caves in all of a sudden, creating large holes in the ground and sometimes devouring whole buildings. Geologists have offered various theories for the natural causes of sinkholes such as the type of soil / rock giving way to rainwater and underground water. Other natural causes submitted by experts include heavy rainfall, global warming, underground gas explosions, etc. They can also occur from the over-pumping and extraction of groundwater and subsurface fluids. In Turkey, especially mid and south-east Anatolian regions have very arid soils. There is not sufficient rain and irrigation in these regions. Despite of using 75% of the fresh water for agriculture, old methods of irrigation causes wastefulness of water. Planless and randomly used water causes difficulties in agriculture. These regions are known as granary in the country. Because of drought, farmers use underground water with draw well unconsciously. At the result of underground water movement and withdrawal of water to surface, depression and very huge holes are occurred in the ground with tremendous noise. During the last two years dozens of sinkholes occurred in these regions in Turkey. Most of them are in the rural area, the others are also in center of the cities. Various sizes of holes scare the people living in these regions. In this study, sinkholes, which are occurred in different dimensions in central Anatolia region in the last years, are observed and the causes of these formations are examined. According to the reasons, suggestions to avoid these formations will be given respectively.

  19. 30 CFR 75.901 - Protection of low- and medium-voltage three-phase circuits used underground.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... the generator frame and between the wye-connected transformer secondary and the transformer frame when an isolation transformer(s) is used and the generator is supplying power to the other equipment; (see... and the generator frame when an auto-transformer is used. (see Figure III in Appendix A to subpart J...

  20. 30 CFR 75.901 - Protection of low- and medium-voltage three-phase circuits used underground.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... the generator frame and between the wye-connected transformer secondary and the transformer frame when an isolation transformer(s) is used and the generator is supplying power to the other equipment; (see... and the generator frame when an auto-transformer is used. (see Figure III in Appendix A to subpart J...

  1. 30 CFR 75.901 - Protection of low- and medium-voltage three-phase circuits used underground.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... the generator frame and between the wye-connected transformer secondary and the transformer frame when an isolation transformer(s) is used and the generator is supplying power to the other equipment; (see... and the generator frame when an auto-transformer is used. (see Figure III in Appendix A to subpart J...

  2. 30 CFR 75.901 - Protection of low- and medium-voltage three-phase circuits used underground.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... the generator frame and between the wye-connected transformer secondary and the transformer frame when an isolation transformer(s) is used and the generator is supplying power to the other equipment; (see... and the generator frame when an auto-transformer is used. (see Figure III in Appendix A to subpart J...

  3. 30 CFR 75.901 - Protection of low- and medium-voltage three-phase circuits used underground.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... the generator frame and between the wye-connected transformer secondary and the transformer frame when an isolation transformer(s) is used and the generator is supplying power to the other equipment; (see... and the generator frame when an auto-transformer is used. (see Figure III in Appendix A to subpart J...

  4. Near-source mobile methane emission estimates using EPA Method33a and a novel probabilistic approach as a basis for leak quantification in urban areas

    EPA Science Inventory

    Methane emissions from underground pipeline leaks remain an ongoing issue in the development of accurate methane emission inventories for the natural gas supply chain. Application of mobile methods during routine street surveys would help address this issue, but there are large ...

  5. A geological and geotechnical investigation of the settlement area of Zümrüt Building (Konya, Turkey) which caused 92 fatalities due to its collapse

    NASA Astrophysics Data System (ADS)

    Özdemir, Adnan

    2008-02-01

    This study examines the local geological conditions and soil structure as possible causes of the collapse of the Zümrüt Building 2 February 2004. This catastrophe resulted in 92 fatalities and 35 injuries. This study also examines other views which claim weak soil structure, elastic and consolidation settlement of soil and excessive groundwater extraction as well as subsidence resulting from the underground silt erosion as possible factors. Zümrüt Building was constructed on normally consolidated, low plasticity clay. The underground water table was 30 m in depth. The internal friction angle of soil was 8°-30°, its cohesion was between 34 and 127 kN/m2 and standard penetration test numbers varied between 11 and 50. The underground water level beneath Zümrüt Building had risen 4.5 m since its construction. Therefore the claim that subsidence resulting from the decrease of underground water level contributed to the collapse is incorrect. Secondly the settlement, resulting from the filling up of the pores created by the silt receding with the underground water, was 4.4 mm in total, and attributing this as the primary cause of the collapse is also incorrect. Soil properties, in situ and laboratory test results showed that the existing and/or expected settlement and the differential ground settlement in the Zümrüt building vicinity had the potential to cause structural damage. The tensile stresses caused by differential settlements recorded here are thought to be an indicator, but not the main cause contributing to the collapse of the building. The Zümrüt Building collapse was due to several compounding mistakes during the construction phase. These were geotechnical and other project faults and the use of low quality construction materials. The resulting catastrophe caused 92 fatalities, 35 injuries and a material loss of approximately US7 million.

  6. 40 CFR 144.83 - Do I need to notify anyone about my Class V injection well?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) and 146.5(e)(8) of this chapter); (B) Geothermal energy recovery wells (40 CFR 144.81(11) and 146.5 (e... information believed necessary to protect underground sources of drinking water. (1) Such information...) Conduct other analyses and submit other information, if needed to protect underground sources of drinking...

  7. 40 CFR 144.83 - Do I need to notify anyone about my Class V injection well?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) and 146.5(e)(8) of this chapter); (B) Geothermal energy recovery wells (40 CFR 144.81(11) and 146.5 (e... information believed necessary to protect underground sources of drinking water. (1) Such information...) Conduct other analyses and submit other information, if needed to protect underground sources of drinking...

  8. 40 CFR 144.83 - Do I need to notify anyone about my Class V injection well?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) and 146.5(e)(8) of this chapter); (B) Geothermal energy recovery wells (40 CFR 144.81(11) and 146.5 (e... information believed necessary to protect underground sources of drinking water. (1) Such information...) Conduct other analyses and submit other information, if needed to protect underground sources of drinking...

  9. 40 CFR 144.83 - Do I need to notify anyone about my Class V injection well?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) and 146.5(e)(8) of this chapter); (B) Geothermal energy recovery wells (40 CFR 144.81(11) and 146.5 (e... information believed necessary to protect underground sources of drinking water. (1) Such information...) Conduct other analyses and submit other information, if needed to protect underground sources of drinking...

  10. Land subsidence monitoring in central Taiwan by using PS-InSAR technique

    NASA Astrophysics Data System (ADS)

    Hu, J.-C.; Tung, H.; Huang, M.-H.

    2009-04-01

    Ground subsidence induced by heavy withdrawal of underground water has resulted in environmental hazard and potential risk in Taiwan, particularly in the Choushui River alluvial fan where the Yunlin section of the Taiwan High Speed Rail had been constructed. The Yunlin County located in the southwestern coastal region of Taiwan is one of the most counties with serious land subsidence because of the agricultural needs. Yunlin County is one of the important agricultural production regions located in the southwestern coastal region of Taiwan where the irrigated area is up to 123,000 hectares and agricultural water consumption reaches approximate 90 percents of all available water resources in the Choshui River Basin. Moreover, since there is no sufficient surface water supplied, groundwater becomes a vital resource for every water consumption targets. Seasonal effects of land subsidence occurring in the study area had been estimated using a regression analysis of a series of weekly GPS height solutions. These results demonstrated the average rate of ground subsidence in this area over the period of 1995-2001 was 3 cm/yr. Based on data collected at the piezometer, the variation of land subsidence rate appears to be associated with an unstable underground water level, which drop gradually during winter and either remains constant or rises during summer time. Consequently, land subsidence rates vary considerably from 1.5 cm/yr for the summer time to 9.0 cm/yr for the winter time. In addition, anthropogenic ground subsidence due to massive pumping of groundwater is one of problems in Taiwan. In this study, we represented a both stacking D-InSAR and PS-InSAR results deduced from 1996-1999 time spans for monitoring of land subsidence in this area. Both D-InSAR and PS-InSAR results show the Baojhou, Tuku Township and northern Mailiao reveal a maximum subsidence rate of about 6 cm/yr along LOS and the Taishi Township located on the coastal area reveals a subsidence rate of 1.6 cm/yr, which is quite coincident with precise leveling result. These two results have proven that the effective reduction of labor and cost could be achieved by using this technique on monitoring land subsidence in Yunlin County.

  11. Design of Meter-Scale Antenna and Signal Detection System for Underground Magnetic Resonance Sounding in Mines.

    PubMed

    Yi, Xiaofeng; Zhang, Jian; Fan, Tiehu; Tian, Baofeng; Jiang, Chuandong

    2018-03-13

    Magnetic resonance sounding (MRS) is a novel geophysical method to detect groundwater directly. By applying this method to underground projects in mines and tunnels, warning information can be provided on water bodies that are hidden in front prior to excavation and thus reduce the risk of casualties and accidents. However, unlike its application to ground surfaces, the application of MRS to underground environments is constrained by the narrow space, quite weak MRS signal, and complex electromagnetic interferences with high intensities in mines. Focusing on the special requirements of underground MRS (UMRS) detection, this study proposes the use of an antenna with different turn numbers, which employs a separated transmitter and receiver. We designed a stationary coil with stable performance parameters and with a side length of 2 m, a matching circuit based on a Q-switch and a multi-stage broad/narrowband mixed filter that can cancel out most electromagnetic noise. In addition, noises in the pass-band are further eliminated by adopting statistical criteria and harmonic modeling and stacking, all of which together allow weak UMRS signals to be reliably detected. Finally, we conducted a field case study of the UMRS measurement in the Wujiagou Mine in Shanxi Province, China, with known water bodies. Our results show that the method proposed in this study can be used to obtain UMRS signals in narrow mine environments, and the inverted hydrological information generally agrees with the actual situation. Thus, we conclude that the UMRS method proposed in this study can be used for predicting hazardous water bodies at a distance of 7-9 m in front of the wall for underground mining projects.

  12. Design of Meter-Scale Antenna and Signal Detection System for Underground Magnetic Resonance Sounding in Mines

    PubMed Central

    Yi, Xiaofeng; Fan, Tiehu; Tian, Baofeng

    2018-01-01

    Magnetic resonance sounding (MRS) is a novel geophysical method to detect groundwater directly. By applying this method to underground projects in mines and tunnels, warning information can be provided on water bodies that are hidden in front prior to excavation and thus reduce the risk of casualties and accidents. However, unlike its application to ground surfaces, the application of MRS to underground environments is constrained by the narrow space, quite weak MRS signal, and complex electromagnetic interferences with high intensities in mines. Focusing on the special requirements of underground MRS (UMRS) detection, this study proposes the use of an antenna with different turn numbers, which employs a separated transmitter and receiver. We designed a stationary coil with stable performance parameters and with a side length of 2 m, a matching circuit based on a Q-switch and a multi-stage broad/narrowband mixed filter that can cancel out most electromagnetic noise. In addition, noises in the pass-band are further eliminated by adopting statistical criteria and harmonic modeling and stacking, all of which together allow weak UMRS signals to be reliably detected. Finally, we conducted a field case study of the UMRS measurement in the Wujiagou Mine in Shanxi Province, China, with known water bodies. Our results show that the method proposed in this study can be used to obtain UMRS signals in narrow mine environments, and the inverted hydrological information generally agrees with the actual situation. Thus, we conclude that the UMRS method proposed in this study can be used for predicting hazardous water bodies at a distance of 7–9 m in front of the wall for underground mining projects. PMID:29534007

  13. Synergistic efficiency of the desilication of brackish underground water in Saudi Arabia by coupling γ-radiation and Fenton process: Membrane scaling prevention in reverse osmosis process

    NASA Astrophysics Data System (ADS)

    Aljohani, Mohammed S.

    2017-12-01

    One of the main water resources in arid Saudi Arabia is underground water. However, this brackish water has high silica content which can cause a recalcitrant deposit on the membrane in the reverse osmosis units during its desalination. In this study, we examined the synergistic efficiency of the removal of silica from the Buwaib water sample, when combining two advanced oxidation processes, γ-irradiation and the Fenton process, using hydrogen peroxide and zero valent metal iron as source of Fe3+. This latter adsorbs effectively on silica and co-precipitate. The influence of absorbed dose, iron dosage and pH effect were investigated. This preliminary study showed that these attractive and effective hybrid processes are very efficient in removing silica.

  14. 75 FR 77229 - Federal Requirements Under the Underground Injection Control (UIC) Program for Carbon Dioxide (CO2

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-10

    ...This action finalizes minimum Federal requirements under the Safe Drinking Water Act (SDWA) for underground injection of carbon dioxide (CO2) for the purpose of geologic sequestration (GS). GS is one of a portfolio of options that could be deployed to reduce CO2 emissions to the atmosphere and help to mitigate climate change. This final rule applies to owners or operators of wells that will be used to inject CO2 into the subsurface for the purpose of long-term storage. It establishes a new class of well, Class VI, and sets minimum technical criteria for the permitting, geologic site characterization, area of review (AoR) and corrective action, financial responsibility, well construction, operation, mechanical integrity testing (MIT), monitoring, well plugging, post-injection site care (PISC), and site closure of Class VI wells for the purposes of protecting underground sources of drinking water (USDWs). The elements of this rulemaking are based on the existing Underground Injection Control (UIC) regulatory framework, with modifications to address the unique nature of CO2 injection for GS. This rule will help ensure consistency in permitting underground injection of CO2 at GS operations across the United States and provide requirements to prevent endangerment of USDWs in anticipation of the eventual use of GS to reduce CO2 emissions to the atmosphere and to mitigate climate change.

  15. [Research on the sensitivity of geochemical of underground river in Chongqing Xueyu Cave].

    PubMed

    Xu, Shang-Quan; Yang, Ping-Heng; Yin, Jian-Jun; Mao, Hai-Hong; Wang, Peng; Zhou, Xiao-Ping

    2013-01-01

    Quoted geochemical susceptivity index and isosensitive line on geochemical susceptivity, analyzed the data of underground rivers of Xueyu Cave in Chongqing from September 2010 to August 2011, we found that the chemical composition of the underground river was controlled by the bedrock, due to the composition of high concentration of Ca2+ and low concentration of Mg2+. Owing to the effects of the monsoon, water chemistry was different between drought season and rainy season: the value of [Mg2+]/[Ca2+] was 0.018-0.051 in the rainy season, but in dry season the value was 0.038-0.064. The value of [HCO3(-)]/[SO4(2-)] was 4.86-36.62 in the rainy season, and 6.23-46.67 in the dry season. The seasonal change of Karstification made Ca2+ and HCO3(-) become the most sensitive ion. As a result of the special hydrogeological structure in Karat area, rain, surface water and groundwater transformed rapidly, which caused the underground river was sensitive to agricultural activities, especially for Cl- and NO3(-), and their sensitive indices were 0.286 and 0.022 respectively. The influence of tourism activities on the underground river was less than the management. The management work of ecological system should be strengthen in the recharge area, thus the largest economic and environmental benefits in the Karst area could be achieved.

  16. A cost-benefit analysis of produced water management opportunities in selected unconventional oil and gas plays

    NASA Astrophysics Data System (ADS)

    Marsters, P.; Macknick, J.; Bazilian, M.; Newmark, R. L.

    2013-12-01

    Unconventional oil and gas production in North America has grown enormously over the past decade. The combination of horizontal drilling and hydraulic fracturing has made production from shale and other unconventional resources economically attractive for oil and gas operators, but has also resulted in concerns over potential water use and pollution issues. Hydraulic fracturing operations must manage large volumes of water on both the front end as well as the back end of operations, as significant amounts of water are coproduced with hydrocarbons. This water--often called flowback or produced water--can contain chemicals from the hydraulic fracturing fluid, salts dissolved from the source rock, various minerals, volatile organic chemicals, and radioactive constituents, all of which pose potential management, safety, and public health issues. While the long-term effects of hydraulic fracturing on aquifers, drinking water supplies, and surface water resources are still being assessed, the immediate impacts of produced water on local infrastructure and water supplies are readily evident. Produced water management options are often limited to underground injection, disposal at centralized treatment facilities, or recycling for future hydraulic fracturing operations. The costs of treatment, transport, and recycling are heavily dependent on local regulations, existing infrastructure, and technologies utilized. Produced water treatment costs also change over time during energy production as the quality of the produced water often changes. To date there is no publicly available model that evaluates the cost tradeoffs associated with different produced water management techniques in different regions. This study addresses that gap by characterizing the volume, qualities, and temporal dynamics of produced water in several unconventional oil and gas plays; evaluating potential produced water management options, including reuse and recycling; and assessing how hydraulic fracturing and produced water issues relate to the larger water-energy nexus. Specifically, this study develops a play-specific model to compare the decision factors and costs involved in managing produced water. For example, when transport distances to a wastewater disposal site are far enough, options for recycling water become more favorable, depending on the characteristics of each play. This model can provide policymakers and other interested parties with cost estimates of different water management options, including a better understanding of the costs and opportunities associated with recycling produced water. This work provides a cross-play assessment of produced water management options and costs and could serve as the foundation for more detailed analyses of opportunities to minimize hydraulic fracturing's impacts on freshwater resources.

  17. Development of a low background liquid scintillation counter for a shallow underground laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Erchinger, Jennifer L.; Aalseth, Craig E.; Bernacki, Bruce E.

    2015-08-20

    Pacific Northwest National Laboratory has recently opened a shallow underground laboratory intended for measurement of lowconcentration levels of radioactive isotopes in samples collected from the environment. The development of a low-background liquid scintillation counter is currently underway to further augment the measurement capabilities within this underground laboratory. Liquid scintillation counting is especially useful for measuring charged particle (e.g., B, a) emitting isotopes with no (orvery weak) gamma-ray yields. The combination of high-efficiency detection of charged particle emission in a liquid scintillation cocktail coupled with the low-background environment of an appropriately-designed shield located in a clean underground laboratory provides the opportunitymore » for increased-sensitivity measurements of a range of isotopes. To take advantage of the 35-meter water-equivalent overburden of the underground laboratory, a series of simulations have evaluated the instrumental shield design requirements to assess the possible background rate achievable. This report presents the design and background evaluation for a shallow underground, low background liquid scintillation counter design for sample measurements.« less

  18. [Drinking water quality indices in the Orenburg Region].

    PubMed

    Golubkina, N A; Burtseva, T I; Gatsenko, A Iu

    2011-01-01

    The quality of underground waters from 22 areas of the Orenburg Region was studied from the values of mineralization and pH and the amounts of the ions of Se, Cl, Pb, Cd, F, and phenols. High fluorine ion concentrations (5-12 mg/l), high mineralization (> 1 g/l), and alkalinity (pH > 8.0) were shown to be human risk factors in a considerable number of areas. Districts with cadmium, lead, and phenol ion-polluted underground waters were identified. The amount of selenium in the drinking water (18-319 ng/l) and in the sera of donors in Orenburg, Buzuluk, and Orsk (86-97 microg/l) fails to support the data available in the literature on environmental selenium pollution and is comparable with the relevant data for the Moscow Region.

  19. Multi-geophysical approaches to detect karst channels underground - A case study in Mengzi of Yunnan Province, China

    NASA Astrophysics Data System (ADS)

    Gan, Fuping; Han, Kai; Lan, Funing; Chen, Yuling; Zhang, Wei

    2017-01-01

    Mengzi locates in the south 20 km away from the outlet of Nandong subsurface river, and has been suffering from water deficiency in recent years. It is necessary to find out the water resources underground according to the geological characteristics such as the positions and buried depths of the underground river to improve the civil and industrial environments. Due to the adverse factors such as topographic relief, bare rocks in karst terrains, the geophysical approaches, such as Controlled Source Audio Magnetotellurics and Seismic Refraction Tomography, were used to roughly identify faults and fracture zones by the geophysical features of low resistivity and low velocity, and then used the mise-a-la-masse method to judge which faults and fracture zones should be the potential channels of the subsurface river. Five anomalies were recognized along the profile of 2.4 km long and showed that the northeast river system has several branches. Drilling data have proved that the first borehole indicated a water bearing channel by a characteristics of rock core of river sands and gravels deposition, the second one encountered water-filled fracture zone with abundant water, and the third one exposed mud-filled fracture zone without sustainable water. The results from this case study show that the combination of Controlled Source Audio Magnetotellurics, Seismic Refraction Tomography and mise-a-la-Masse is one of the effective methods to detect water-filled channels or fracture zones in karst terrains.

  20. Contamination mechanisms of air basin with tritium in venues of underground nuclear explosions at the former Semipalatinsk test site.

    PubMed

    Lyakhova, O N; Lukashenko, S N; Larionova, N V; Tur, Y S

    2012-11-01

    During the period of testing from 1945 to 1962 at the territory of Semipalatinsk test site (STS) within the Degelen Mountains in tunnels, 209 underground nuclear explosions were produced. Many of the tunnels have seasonal water seepage in the form of streams, through which tritium migrates from the underground nuclear explosion (UNE) venues towards the surface. The issue of tritium contamination occupies a special place in the radioactive contamination of the environment. In this paper we assess the level and distribution of tritium in the atmospheric air of ecosystems with water seepage at tunnels № 176 and № 177, located on "Degelen" site. There has been presented general nature of tritium distribution in the atmosphere relative to surface of a watercourse which has been contaminated with tritium. The basic mechanisms were studied for tritium distribution in the air of studied ecosystems, namely, the distribution of tritium in the systems: water-atmosphere, tunnel air-atmosphere, soil water-atmosphere, vegetation-atmosphere. An analytical calculation of tritium concentration in the atmosphere by the concentration of tritium in water has been performed. There has experimentally obtained the dependence for predictive assessment of tritium concentrations in air as a function of tritium concentration in one of the inlet sources such as water, tunnel air, soil water, vegetation, etc.. The paper also describes the general nature of tritium distribution in the air in the area "Degelen". Copyright © 2012 Elsevier Ltd. All rights reserved.

  1. 40 CFR 147.2903 - Prohibition of unauthorized injection.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... sources of drinking water and the well bore is prohibited. .... 147.2903 Section 147.2903 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER... any contaminant into underground sources of drinking water, if the presence of that contaminant may...

  2. 40 CFR 147.2903 - Prohibition of unauthorized injection.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... sources of drinking water and the well bore is prohibited. .... 147.2903 Section 147.2903 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER... any contaminant into underground sources of drinking water, if the presence of that contaminant may...

  3. 40 CFR 147.2903 - Prohibition of unauthorized injection.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... sources of drinking water and the well bore is prohibited. .... 147.2903 Section 147.2903 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER... any contaminant into underground sources of drinking water, if the presence of that contaminant may...

  4. 40 CFR 147.2903 - Prohibition of unauthorized injection.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... sources of drinking water and the well bore is prohibited. .... 147.2903 Section 147.2903 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER... any contaminant into underground sources of drinking water, if the presence of that contaminant may...

  5. 40 CFR 147.2903 - Prohibition of unauthorized injection.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... sources of drinking water and the well bore is prohibited. .... 147.2903 Section 147.2903 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER... any contaminant into underground sources of drinking water, if the presence of that contaminant may...

  6. Modeling and monitoring the hydrological effects of the Sand Engine.

    NASA Astrophysics Data System (ADS)

    Schaars, Frans; Hoogmoed, Merel; van Vliet, Frank; Stuyfzand, Pieter; Groen, Michel; van der Made, Kees-Jan; Caljé, Ruben; Auken, Esben; Bergsted Pedersen, Jesper

    2013-04-01

    Since 1887, Dunea Water Company produces high quality drinking water using the dune area at Monster (Province of South Holland, the Netherlands). Annually, 8 billion liters of water is produced here using artificial recharge and recovery with shallow wells and infiltration lakes. The dunes are an important step in producing drinking water serving as an underground buffer, leveling fluctuating in temperature and quality and removing bacteria and viruses from the infiltrated water in a natural way. Since space is limited in the Netherlands, the drinking water production of Dunea is closely matched with surrounding land uses and natural constraints. This prevents groundwater nuisance, upconing and intrusion of salt water and, in this case, movement of a nearby groundwater pollution. This is especially true in the Monster area where the dunes are fairly low and small; the coast is less than 350 meters from the recovery wells. The coast of Monster was identified as a weak link in the coastal defense of The Netherlands. Because of this, two coastal defense projects were carried out between 2009 and 2011. The first project involved creating an extra dune ridge in front of existing dunes which leads to intrusion of a large volume of seawater. Directly after completion, the Sand Engine was constructed. This hook shaped sand peninsula will supply the coast with sand for the coming decades due to erosion and deposition along the coast. These two large coastal defense projects would obviously influence the tightly balanced hydrological system of Monster. Without hydrological intervention, the drinking water production would no longer be sustainable in this area. To study the effects of these projects and to find a solution to combine coastal defense and drinking water supply, field research and effect (geochemical) modeling were used interactively. To prevent negative effects it was decided to construct interception wells on top of the new dune ridge (28 in total). A comprehensive monitoring system was built to keep track of the salt groundwater and the groundwater heads. The zero measurement included groundwater heads, water samples, but also geophysical methods such as SkyTEM and CVES. We will also show the monitoring system we use to keep track of the groundwater heads and salt water intrusion in the future.

  7. A 3-D hydrologic transport model of a water recharge system using carbamazepine and chloride as tracers

    NASA Astrophysics Data System (ADS)

    Rona, Michael; Gasser, Guy; Negev, Ido; Pankratov, Irena; Elhanany, Sara; Lev, Ovadia; Gvirtzman, Haim

    2014-05-01

    Wastewater recharge facilities are often used as a final water treatment before the discharge to the sea or before water reclamation. These facilities are often located in active aquifers that supply drinking water. Thus, leakage from the water recharge facility and gradual expansion of the underground wastewater plume are of considerable health concern. Hydrological modeling of water recharge systems are widely used as operational and predictive tools. These models rely on distributed water head monitoring and at least one chemical or physical tracer to model solutes' transport. Refractory micropollutants have proven useful in qualitative identification of pollution leakages and for quantification of pollution to a specific site near water recharge facilities. However, their usefulness as tracers for hydrological modeling is still questionable. In this article, we describe a long term, 3-D hydraulic model of a large-scale wastewater effluents recharge system in which a combination of chloride and a refractory micropollutant, carbamazepine is used to trace the solute transport. The combination of the two tracers provides the model with the benefits of the high specificity of the carbamazepine and the extensive historic data base that is available for chloride. The model predicts westward expansion of the pollution plume, whereas a standing front is formed at the east. These trends can be confirmed by the time trace of the carbamazepine concentrations at specific locations. We show that the combination of two tracers accounts better (at least at some locations) for the evolution of the pollution plume than a model based on chloride or carbamazepine alone.

  8. Ecologization of water-land property matters on the territory of the Tom lower course

    NASA Astrophysics Data System (ADS)

    Popov, V. K.; Kozina, M. V.; Levak, Yu Yu; Shvagrukova, E. V.

    2016-03-01

    In the present paper the water-land property complex is considered as a strategic resource of the city development. The formulated question is expounded through the example of water-land property complex usage on the territory of the Tom lower course for land-use planning and developing the systems of water recourses management and land tenure. Consequences of liquid radioactive waste (LRW) landfilling are investigated in terms of arable farming. Also, forming a water budget of the soils spread on the area of the Tomsk underground water supply cone of depression and its role in the development of agricultural industry are studied. The main aspect of the analysis is the incorporation of social, economic, and ecological requirements for the system of life-supporting branches of municipal economy and social services. As far as the system of land tax payments plays an important role in land property complex management, the common issues and tendencies are specified in the paper. These problems are concerned with the inadequate incorporation of an ecological constituent in the methods of cadastral valuation of lands, as well as the situation of the narrow area of its results usage in the Russian Federation. Natural factors (hydrological, territorial, geological (geomorphologic) territory conditions) are combined by the authors into a special group. These factors should be reflected in the results of cadastral valuation. Also, in order to protect the interests of water consumers, it is offered to establish the Water Consumers Association based on the international experience of such countries as Spain and Uzbekistan.

  9. Radiation processing applications in the Czechoslovak water treatment technologies

    NASA Astrophysics Data System (ADS)

    Vacek, K.; Pastuszek, F.; Sedláček, M.

    The regeneration of biologically clogged water wells by radiation proved to be a successful and economically beneficial process among other promising applications of ionizing radiation in the water supply technology. The application conditions and experience are mentioned. The potential pathogenic Mycobacteria occuring in the warm washing and bathing water are resistant against usual chlorine and ozone concentrations. The radiation sensitivity of Mycobacteria allowed to suggest a device for their destroying by radiation. Some toxic substances in the underground water can be efficiently degraded by gamma radiation directly in the wells drilled as a hydraulic barrier surrounding the contaminated land area. Substantial decrease of CN - concentration and C.O.D. value was observed in water pumped from such well equipped with cobalt sources and charcoal. The removing of pathogenic contamination remains to be the main goal of radiation processing in the water purification technologies. The decrease of liquid sludge specific filter resistance and sedimentation acceleration by irradiation have a minor technological importance. The hygienization of sludge cake from the mechanical belt filter press by electron beam appears to be the optimum application in the Czechoslovak conditions. The potatoes and barley crop yields from experimental plots treated with sludge were higher in comparison with using the manure. Biological sludge from the municipal and food industry water purification plants contains nutritive components. The proper hygienization is a necessary condition for using them as a livestock feed supplement. Feeding experiments with broilers and pigs confirmed the possibility of partial (e.g. 50%) replacement of soya-, bone- or fish flour in feed mixtures by dried sludge hygienized either by heat or by the irradiation.

  10. The effect of spatially varying velocity field on the transport of radioactivity in a porous medium.

    PubMed

    Sen, Soubhadra; Srinivas, C V; Baskaran, R; Venkatraman, B

    2016-10-01

    In the event of an accidental leak of the immobilized nuclear waste from an underground repository, it may come in contact of the flow of underground water and start migrating. Depending on the nature of the geological medium, the flow velocity of water may vary spatially. Here, we report a numerical study on the migration of radioactivity due to a space dependent flow field. For a detailed analysis, seven different types of velocity profiles are considered and the corresponding concentrations are compared. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Flooded Underground Coal Mines: A Significant Source of Inexpensive Geothermal Energy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Watzlaf, G.R.; Ackman, T.E.

    2007-04-01

    Many mining regions in the United States contain extensive areas of flooded underground mines. The water within these mines represents a significant and widespread opportunity for extracting low-grade, geothermal energy. Based on current energy prices, geothermal heat pump systems using mine water could reduce the annual costs for heating to over 70 percent compared to conventional heating methods (natural gas or heating oil). These same systems could reduce annual cooling costs by up to 50 percent over standard air conditioning in many areas of the country. (Formatted full-text version is released by permission of publisher)

  12. Radon Dose Determination for Cave Guides in Czech Republic

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thinova, Lenka; Rovenska, Katerina

    2008-08-07

    According to recommended approach there are six (from total of twelve) open-to-public caves in Czech Republic, reaching near to an effective lung-dose of 6mSv/year. A conservative approach for estimating the potential effective lung-dose in caves (or underground) is based on two season's measurements, using solid state alpha track detector (Kodak in plastic diffusion chamber). The obtained dataset is converted into an annual effective dose, in agreement with the ICRP65 recommendation, using the 'cave factor' 1.5. The value of 'cave factor' which depends on the spectrum of aerosol particles, or on the proportional representation of the unattached/attached ratio (6.5 : 93.5more » for residential places, 13.6 : 86.4 for caves due to lower concentration of free aerosols) and on the equilibrium factor. Thus conversion factor is 1.5 times higher in comparison with ICRP 65. Is this correct? Because a more precisely determined dose value would have a significant impact on radon remedies, or on restricting the time workers stay underground, a series of measurement was initiated in 2003 with the aim to specify input data, computation and errors in effective dose assessment in each one of the evaluated caves separately. The enhancement of personal dosimetry for underground work places includes a study of the given questions, from the following points of view in each cave: continual radon measurement; regular measurements of radon and its daughters to estimate the equilibrium factor and the presence of free {sup 218}Po; regular indoor air flow measurements to study the location of the radon supply and its transfer among individual areas of the cave; natural radioactive element content evaluation in subsoil and in water inside/outside, a study of the radon sources in the cave; determination of the free fraction from continual unattached and attached fraction measurement (grid and filter); thoron measurement. Air flow measurements provide very interesting information about the origin of 'radon pockets' with very high radon concentration, and enable study of the location of the radon supply and its transfer among individual areas of the cave. Most of the results show the equilibrium factor around F = 0.2-0.7 and the unattached fraction around 2%-30%. One of the most important question remains: how accurately was the unattached fraction measured? Part of this project was to verify the influence of etched track detector position in the cave.« less

  13. 40 CFR 144.86 - What are the definitions I need to know?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... of ground water protection areas are identified. (g) Other sensitive ground water areas. States may... to protecting underground sources of drinking water from contamination. These other sensitive ground water areas may include areas such as areas overlying sole-source aquifers; highly productive aquifers...

  14. 40 CFR 144.86 - What are the definitions I need to know?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... of ground water protection areas are identified. (g) Other sensitive ground water areas. States may... to protecting underground sources of drinking water from contamination. These other sensitive ground water areas may include areas such as areas overlying sole-source aquifers; highly productive aquifers...

  15. 40 CFR 144.86 - What are the definitions I need to know?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... of ground water protection areas are identified. (g) Other sensitive ground water areas. States may... to protecting underground sources of drinking water from contamination. These other sensitive ground water areas may include areas such as areas overlying sole-source aquifers; highly productive aquifers...

  16. 40 CFR 144.86 - What are the definitions I need to know?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... of ground water protection areas are identified. (g) Other sensitive ground water areas. States may... to protecting underground sources of drinking water from contamination. These other sensitive ground water areas may include areas such as areas overlying sole-source aquifers; highly productive aquifers...

  17. Didymosphenia geminata in the Upper Esopus Creek: current status, variability, and controlling factors

    USGS Publications Warehouse

    George, Scott D.; Baldigo, Barry P.

    2015-01-01

    In May of 2009, the bloom-forming diatom Didymosphenia geminata was first identified in the Upper Esopus Creek, a key tributary to the New York City water-supply and a popular recreational stream. The Upper Esopus receives supplemental flows from the Shandaken Portal, an underground aqueduct delivering waters from a nearby basin. The presence of D.geminata is a concern for the local economy, water supply, and aquatic ecosystem because nuisance blooms have been linked to degraded stream condition in other regions. Here we ascertain the extent and severity of the D. geminata invasion, determine the impact of supplemental flows from the Portal on D. geminata, and identify potential factors that may limitD. geminata in the watershed. Stream temperature, discharge, and water quality were characterized at select sites and periphyton samples were collected five times at 6 to 20 study sites between 2009 and 2010 to assess standing crop, diatom community structure, and density of D. geminata and all diatoms. Density of D. geminata ranged from 0–12 cells cm-2 at tributary sites, 0–781 cells cm-2 at sites upstream of the Portal, and 0–2,574 cells cm-2 at sites downstream of the Portal. Survey period and Portal (upstream or downstream) each significantly affected D. geminata cell density. In general, D. geminata was most abundant during the November 2009 and June 2010 surveys and at sites immediately downstream of the Portal. We found that D. geminata did not reach nuisance levels or strongly affect the periphyton community. Similarly, companion studies showed that local macroinvertebrate and fish communities were generally unaffected. A number of abiotic factors including variable flows and moderate levels of phosphorous and suspended sediment may limit blooms of D. geminatain this watershed.

  18. 43 CFR 3436.2-1 - Qualified exchange proponents.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... interrupt farming or materially damage the quantity and quality of the water in surface or underground water... Control and Reclamation Act. (b) Exchange proponents bear the burden of establishing their qualifications...

  19. 43 CFR 3436.2-1 - Qualified exchange proponents.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... interrupt farming or materially damage the quantity and quality of the water in surface or underground water... Control and Reclamation Act. (b) Exchange proponents bear the burden of establishing their qualifications...

  20. Clean Water State Revolving Fund (CWSRF): Contaminated Sites

    EPA Pesticide Factsheets

    Communities can use the CWSRF to address the water quality aspects of site assessment and cleanup of brownfields, Superfund sites, and sites of current or former aboveground or underground storage tanks.

  1. 78 FR 31598 - Proposed Collection; Comment Request; Operations Under Water

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-24

    ...; Operations Under Water AGENCY: Mine Safety and Health Administration, Labor. ACTION: 60-Day Notice. SUMMARY... under bodies of water and to obtain a permit to mine under a body of water if, in the judgment of the... the inundation of underground coal mines with water that has the potential of drowning miners. Section...

  2. 77 FR 40354 - Permitting Guidance for Oil and Gas Hydraulic Fracturing Activities Using Diesel Fuels-Draft

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-09

    ... INFORMATION CONTACT: Sherri Comerford, Underground Injection Control (UIC) Program, Drinking Water Protection Division, Office of Ground Water and Drinking Water (MC-4606M), Environmental Protection Agency, 1200... Fracturing and the Safe Drinking Water Act Web site, http://water.epa.gov/type/groundwater/uic/class2...

  3. Groundwater-pumping optimization for land-subsidence control in Beijing plain, China

    NASA Astrophysics Data System (ADS)

    Qin, Huanhuan; Andrews, Charles B.; Tian, Fang; Cao, Guoliang; Luo, Yong; Liu, Jiurong; Zheng, Chunmiao

    2018-01-01

    Beijing, in the North China plain, is one of the few megacities that uses groundwater as its main source of water supply. Groundwater accounts for about two-thirds of the city's water supply, and during the past 50 years the storage depletion from the unconsolidated aquifers underlying the city has been >10.4 billion m3. By 2010, groundwater pumping in the city had resulted in a cumulative subsidence of greater than 100 mm in an area of about 3,900 km2, with a maximum cumulative subsidence of >1,200 mm. This subsidence has caused significant social and economic losses in Beijing, including significant damage to underground utilities. This study was undertaken to evaluate various future pumping scenarios to assist in selecting an optimal pumping scenario to minimize overall subsidence, meet the requirements of the Beijing Land Subsidence Prevention Plan (BLSPP 2013-2020), and be consistent with continued sustainable economic development. A numerical groundwater and land-subsidence model was developed for the aquifer system of the Beijing plain to evaluate land subsidence rates under the possible future pumping scenarios. The optimal pumping scenario consistent with the evaluation constraints is a reduction in groundwater pumping from three major pumping centers by 100, 50 and 20%, respectively, while maintaining an annual pumping rate of 1.9 billion m3. This scenario's land-subsidence rates satisfy the BLSPP 2013-2020 and the pumping scenario is consistent with continued economic development. It is recommended that this pumping scenario be adopted for future land-subsidence management in Beijing.

  4. Groundwater-pumping optimization for land-subsidence control in Beijing plain, China

    NASA Astrophysics Data System (ADS)

    Qin, Huanhuan; Andrews, Charles B.; Tian, Fang; Cao, Guoliang; Luo, Yong; Liu, Jiurong; Zheng, Chunmiao

    2018-06-01

    Beijing, in the North China plain, is one of the few megacities that uses groundwater as its main source of water supply. Groundwater accounts for about two-thirds of the city's water supply, and during the past 50 years the storage depletion from the unconsolidated aquifers underlying the city has been >10.4 billion m3. By 2010, groundwater pumping in the city had resulted in a cumulative subsidence of greater than 100 mm in an area of about 3,900 km2, with a maximum cumulative subsidence of >1,200 mm. This subsidence has caused significant social and economic losses in Beijing, including significant damage to underground utilities. This study was undertaken to evaluate various future pumping scenarios to assist in selecting an optimal pumping scenario to minimize overall subsidence, meet the requirements of the Beijing Land Subsidence Prevention Plan (BLSPP 2013-2020), and be consistent with continued sustainable economic development. A numerical groundwater and land-subsidence model was developed for the aquifer system of the Beijing plain to evaluate land subsidence rates under the possible future pumping scenarios. The optimal pumping scenario consistent with the evaluation constraints is a reduction in groundwater pumping from three major pumping centers by 100, 50 and 20%, respectively, while maintaining an annual pumping rate of 1.9 billion m3. This scenario's land-subsidence rates satisfy the BLSPP 2013-2020 and the pumping scenario is consistent with continued economic development. It is recommended that this pumping scenario be adopted for future land-subsidence management in Beijing.

  5. The mathematical model of radon-222 accumulation in underground mines

    NASA Astrophysics Data System (ADS)

    Klimshin, A.

    2012-04-01

    Necessity to control underground mine air radon level arises during building and operating mines as well as auto and railway tunnels including those for metros. Calculation of underground mine air radon level can be fulfilled for estimation of potential radon danger of area for underground structure building. In this work the new mathematical model of radon accumulation in underground mines has been suggested. It takes into consideration underground mine dimensions, air exchange factor and soils ability to emanate radon. The following assumptions have been taken for model development. It is assumed that underground mine is a cylinder of length L and of base area S. Due to ventilation atmosphere air of volume activity Catm, is coming in through one cylinder base and is going out of volume activity Cind from underground mine. Diffusion radon flux is coming in through side surfaces of underground mine. The sources of this flux are radium-226 atoms distributed evenly in rock. For simplification of the task it considered possible to disregard radon emanation by loosened rock and underground waters. As a result of solution of the radon diffusion equation the following expression for calculation of radon volume activity in underground space air has been got: 2·r0 ·λv ·Catm-·l·K0(r0/l)-+D-·K1(r0/l)·C0- Cind = 2·(λ+ λv)·r0 ·l·K0 (r0/l)+ D ·K1(r0/l) . The following designations are used in this expression: Kν(r) - the second genus modified Bessel's function, C0 - equilibrium radon volume activity in soil air, l - diffusion radon length in soil, D - radon diffusion factor, r0 - radius of underground tunnel, λv - factor of air exchange. Expression found may be used for calculation of the minimum factor of necessary air exchange for ensuring safe radon levels in underground spaces. With this worked out model expected levels of radon volume activity were calculated for air in the second metro line underground spaces in the city of Yekaterinburg, Russia.

  6. 30 CFR 75.1101-6 - Water sprinkler systems; general.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Water sprinkler systems; general. 75.1101-6... SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1101-6 Water sprinkler systems; general. Water sprinkler systems may be installed to protect main and secondary belt...

  7. 30 CFR 75.1716 - Operations under water.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Operations under water. 75.1716 Section 75.1716... MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1716 Operations under water. [Statutory..., and maintenance of tunnels under any river, stream, lake, or other body of water, that is, in the...

  8. 30 CFR 75.1718-1 - Drinking water; quality.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Drinking water; quality. 75.1718-1 Section 75... AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1718-1 Drinking water; quality. (a) Potable water provided in accordance with the provisions of § 75.1718 shall meet the...

  9. 30 CFR 75.1101-6 - Water sprinkler systems; general.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Water sprinkler systems; general. 75.1101-6... SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1101-6 Water sprinkler systems; general. Water sprinkler systems may be installed to protect main and secondary belt...

  10. 30 CFR 75.1718-1 - Drinking water; quality.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Drinking water; quality. 75.1718-1 Section 75... AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1718-1 Drinking water; quality. (a) Potable water provided in accordance with the provisions of § 75.1718 shall meet the...

  11. 30 CFR 75.1718-1 - Drinking water; quality.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Drinking water; quality. 75.1718-1 Section 75... AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1718-1 Drinking water; quality. (a) Potable water provided in accordance with the provisions of § 75.1718 shall meet the...

  12. 30 CFR 75.1718-1 - Drinking water; quality.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Drinking water; quality. 75.1718-1 Section 75... AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1718-1 Drinking water; quality. (a) Potable water provided in accordance with the provisions of § 75.1718 shall meet the...

  13. 30 CFR 75.1716 - Operations under water.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Operations under water. 75.1716 Section 75.1716... MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1716 Operations under water. [Statutory..., and maintenance of tunnels under any river, stream, lake, or other body of water, that is, in the...

  14. 30 CFR 75.1716 - Operations under water.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Operations under water. 75.1716 Section 75.1716... MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1716 Operations under water. [Statutory..., and maintenance of tunnels under any river, stream, lake, or other body of water, that is, in the...

  15. 30 CFR 75.1101-6 - Water sprinkler systems; general.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Water sprinkler systems; general. 75.1101-6... SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1101-6 Water sprinkler systems; general. Water sprinkler systems may be installed to protect main and secondary belt...

  16. 30 CFR 75.1101-6 - Water sprinkler systems; general.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Water sprinkler systems; general. 75.1101-6... SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1101-6 Water sprinkler systems; general. Water sprinkler systems may be installed to protect main and secondary belt...

  17. 30 CFR 75.1101-6 - Water sprinkler systems; general.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Water sprinkler systems; general. 75.1101-6... SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1101-6 Water sprinkler systems; general. Water sprinkler systems may be installed to protect main and secondary belt...

  18. 30 CFR 75.1716 - Operations under water.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Operations under water. 75.1716 Section 75.1716... MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1716 Operations under water. [Statutory..., and maintenance of tunnels under any river, stream, lake, or other body of water, that is, in the...

  19. 30 CFR 75.1718-1 - Drinking water; quality.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Drinking water; quality. 75.1718-1 Section 75... AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1718-1 Drinking water; quality. (a) Potable water provided in accordance with the provisions of § 75.1718 shall meet the...

  20. Spatial heterogeneity of high-resolution Chalk groundwater geochemistry - Underground quarry at Saint Martin-le-Noeud, France

    NASA Astrophysics Data System (ADS)

    Barhoum, S.; Valdès, D.; Guérin, R.; Marlin, C.; Vitale, Q.; Benmamar, J.; Gombert, P.

    2014-11-01

    Chalk groundwater is an important aquifer resource in France because it accounts for a production of 12 million m3 y-1 with a large proportion reserved for drinking water. Processes occurring in the unsaturated zone (UZ) and the overlying superficial formations have a high impact on Chalk groundwater geochemistry and require better understanding. The study site is a former underground Chalk quarry located near Beauvais (France) that extends over 1200 m in length, at a depth ranging from 20 to 30 m. The water table intersects the cavity creating 15 underground ;lake; that give access to the Chalk groundwater. Lakes geochemistry has been studied: water samples were collected in July 2013 and major ion concentrations were analyzed. UZ and clay-with-flints thickness above each lake were estimated qualitatively using an electromagnetic sensor (EM31) and Underground GPS. The results unexpectedly showed that groundwater quality varied widely in spatial terms for both allochthonous and autochthonous ions (e.g., HCO3- ranged from 2.03 to 4.43 meq L-1, NO3- ranged from 0.21 to 1.33 meq L-1). Principal component analysis indicated the impact of agricultural land use on water quality, with the intake of NO3- as well as SO42-, Cl- and Ca2+. Chalk groundwater geochemistry is compared with the nature and structure of the UZ. We highlight correlations (1) between thick clay-with-flints layers and the ions Mg2+ and K+, and (2) between UZ thickness and Na+. In conclusion, this paper identifies various ion sources (agriculture, clay-with-flints and Chalk) and demonstrates different processes in the UZ: dissolution, ionic exchange and solute storage.

  1. Lunar Underground Mining and Construction : A Terrestrial Vision enabling Space Exploration and Commerce

    NASA Astrophysics Data System (ADS)

    Baiden, Greg; Grenier, Louis; Blair, Brad

    As the Space Shuttle, Candarm and Space Station near their useful extended lives before the end of this decade, the question "What will be the next frontier for humans and robots to explore and how will we get there?" needs to be considered. Several countries are planning their next take on the exploration of the solar system. The moon is still a viable destination for several countries for two main reasons: the recent discovery of water improves the prospects of a basic infrastructure capability that would enable future commercial interests to drive the impetus to deploy profitable operations in the near future. The commercial appeal to establish a permanent lunar base should rise in this decade with the prospect of using natural resources available, in particular recently found water. The ability to break water into hydrogen and oxygen for providing the main necessities of life, rocket fuel and air to breathe make this permanent base feasible. Furthermore, several significant environmental issues will force this permanent base underground. These issues include lunar radiation, solar flares, temperature extremes and micro-meteorites. Lunar radiation alone will force this move to rock shielding protection of astronauts as at least 10 metres of rock cover will be required to protect human, animals and plants. As early as 1959 the placecountry-regionUS army considered a permanent underground base on the moon. While the original underground idea has merit space pioneers have strayed from this sensible safe concept. Furthermore, advances in proven telerobotic min-ing technology for terrestrial purposes can provide the opportunity for the commercial interests and perhaps government space programs to consider the concept, design, build and implement an underground lunar habitat and a mining and processing operation from basic infrastructure to commercial deployment of profitable operations. This paper discusses a Canadian concept behind a permanent manned outpost on the moon. The discussion includes the need for an underground outpost, how it might be constructed and the terrestrial technologies that can enable this base to made and used to mine on the moon.

  2. Terminology gap in hydrological cycle

    NASA Astrophysics Data System (ADS)

    Zhuo, Lu; Han, Dawei

    2016-04-01

    Water is central to life on Earth. People have been trying to understand how water moves in the hydrosphere throughout the human history. In the 9th century BC, the famous Greek poet Homer described the hydrological cycle in Iliad as "okeanos whose stream bends back in a circle" with a belief that rivers are ocean-fed from subterranean seas. Later, Aristotle (4th century BC) claimed that most of the water came from underground caverns in which air was transformed into water. It was only until 1674, French scientist Perrault developed the correct concept of the water cycle. In modern times, scientists are interested in understanding the individual processes of the hydrological cycle with a keen focus on runoff which supplies water to rivers, lakes, and oceans. Currently, the prevailing concepts on runoff processes include 'infiltration excess runoff' and 'saturation excess runoff'. However, there is no term to describe another major runoff due to the excess beyond the soil water holding capacity (i.e., the field capacity). We argue that a new term should be introduced to fill this gap, and it could be called 'holding excess runoff' which is compatible with the convention. This new term is significant in correcting a half-century misnomer where 'holding excess runoff' has been incorrectly named as 'saturation excess runoff', which was introduced by the Xinanjiang model in China in 1960s. Similar concept has been adopted in many well-known hydrological models such as PDM and HBV in which the saturation refers to the field capacity. The term 'holding excess runoff' resolves such a common confusion in the hydrological community.

  3. Increasing the Reliability of the Work of Artificial Filtering Arrays for the Purification of Quarry Waste Water

    NASA Astrophysics Data System (ADS)

    Tyulenev, Maxim; Lesin, Yury; Litvin, Oleg; Maliukhina, Elena; Abay, Asmelash

    2017-11-01

    Features of geological structure of the Kuznetsk coal basin stipulate the application of a low-cost open technique of coal mining, which is more advantageous both from the economic standpoint, and by safety criteria of mining. However, open mining affects significantly the water resources of region. Intensive pollution of reservoirs and water courses, exhaustion of the underground water-bearing layers, violation of a hydrographic network, etc. be-long to the main disadvantages of an open technique of coal mining. Besides, the volume of the water coming into the mining producers exceeds signi-ficantly the needed quantity. According to the data of annual reports of ecology and natural resources department, 348.277 million m3 of water were ta-ken away during production of soft coal, brown coal and lignum fossil from waters of Kemerovo region in 2013 (mostly from underground water objects (96,5%) when draining of mine openings). At the same time, only 87.018 million m3 of water (25%) has been used within a year.

  4. Crew Earth Observations (CEO) taken during Expedition Five on the ISS

    NASA Image and Video Library

    2002-08-17

    ISS005-E-9984 (17 August 2002) --- This digital still photograph, taken from the International Space Station (ISS) during its fifth staffing, depicts both agriculture and the petroleum industry, which compete for land use near Denver City, Texas. The photo was recently released by the Earth Sciences and Image Analysis Laboratory at Johnson Space Center. The area is southwest of Lubbock near the New Mexico border. According to analysts studying the station imagery, the economy of this region is almost completely dependent on its underground resources of petroleum and water. Both resources result in distinctive land use patterns visible from space. Historically this area has produced vast quantities of oil and gas since development began in the 1930s. A fine, light-colored grid of roads and pipelines connect well sites over this portion of the Wasson Oil Field, one of the state’s most productive. Since the 1940s, agricultural land use has shifted from grazing to irrigated cultivation of cotton, sorghum, wheat, hay, and corn. The water supply is drawn from wells tapping the vast Ogallala Aquifer. Note the large, circular center-pivot irrigation systems in the lower corners of the image. The largest is nearly a mile in diameter.

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    The 18-acre Joseph Forest Products (JFP) site is a wood-processing facility in the City of Joseph, Wallowa County, Oregon. Land use in the area is predominantly industrial and agricultural. The City of Enterprise uses two springs located 4,000 feet from JFP to serve as its municipal water supply. In 1974, and again from 1977 to 1985, Joseph Forest Products, Inc., used the site as a lumber mill, processing wood into lumber products. The selected remedial action for the site includes demolishing contaminated onsite structures, including the process, storage, and mixing tanks, and the wooden structures and concrete slabs, followed bymore » offsite disposal; decontaminating the concrete drip pad and tanks, followed by recycling or offsite disposal of debris; excavating surface and subsurface soil, with screening and segregation of hazardous waste for offsite disposal, with stabilization, if necessary, prior to disposal at appropriate facilities; backfilling any excavated areas; removing asbestos from the facility, with offsite disposal; removing underground storage tanks and any associated contaminated soil, with scrapping or offsite disposal; monitoring ground water; and implementing institutional controls, including deed and land use restrictions or environmental notices. The estimated capital cost for this remedial action is $550,000, with an annual O M cost of $24,000 for 3 years.« less

  6. The water cycle in a bottle: simulation of a hydrogeological basin

    NASA Astrophysics Data System (ADS)

    Nebot Castelló, M. R.; Leiva Hevia, S.

    2012-04-01

    THE WATER CYCLE IN A BOTTLE: simulation of a hydrogeological basin Author: Mª Roser Nebot (Institut Manuel Blancafort, La Garriga, Barcelona, Spain) Co-author: Sílvia Leiva Hevia (Institut Llicà d'Amunt, Lliça d'Amunt, Barcelona, Spain) The activity can be implemented in a great range of ages, because it has many different levels of depth. It is based on the construction of an analogical model of a hydrogeological basin using a 5L or 8L empty bottle. There are also other hands-on experiences that can be done in relation to the central one, such as creating a fountain, making a cloud, fog, a breeze… The use of a model that the students have to build and interact with enhances the possibility of cooperative and dialogic learning. The set of activities begins with an introduction to see what the students know about the water cycle and to focus on what they are going to work on. It also makes them think about underground water, which is frequently forgotten when drawing and studying the water cycle. Then, the building of the water cycle simulation from an empty bottle is presented, see http://www.xtec.cat/cirel/pla_le/nottingham/roser_nebot/index.htm (Unit 5). You will also find other activities related to the water cycle at the site. The students build the model, water the soil, and observe infiltration and the formation of a lake. Using a syringe they overexploit the well and dry the lake. By making the students label the underground water level and observe how water percolates through the holes in the aquifer we are making them aware that underground water doesn't circulate in rivers inside underground tunnels, but through the interconnected holes and crevices. Inside the bottle there is a little plant to observe evapotranspiration but, because it is very difficult to see the water droplets in the small plant that is inside the set-up, it is advisable to do a parallel experiment using bigger plants in a pot, covering them with a plastic bag tied around the stem, with the soil exposed to air, leaving some of them in the shade and some in the sun. The origin of condensation is thoroughly discussed so that the students understand that evapotranspiration comes from the addition of transpiration (plants) to evaporation. The students also add colouring to simulate contamination and salt to simulate marine intrusion. These activities, together with the overexploitation, help to understand how humans affect nature and how the effects are not the same in different parts of the world. To finish, there are different exercises to review, summarize and complement all that has been learnt through the lesson. To acknowledge the fact that many times underground water is forgotten, as homework they have to surf the net to see the many water cycle drawings and animations that don't show the water in the aquifers, and sometimes when the water is seen, the rocks that contain it are not depicted. They are also encouraged to realize that in water cycle representations, it never rains over the sea and that to adjust to what really happens and that there should also be rain over the oceans and seas. To finish, the idea that within the water cycle model there are many interrelated processes is discussed

  7. Numerical modeling of water spray suppression of conveyor belt fires in a large-scale tunnel.

    PubMed

    Yuan, Liming; Smith, Alex C

    2015-05-01

    Conveyor belt fires in an underground mine pose a serious life threat to miners. Water sprinkler systems are usually used to extinguish underground conveyor belt fires, but because of the complex interaction between conveyor belt fires and mine ventilation airflow, more effective engineering designs are needed for the installation of water sprinkler systems. A computational fluid dynamics (CFD) model was developed to simulate the interaction between the ventilation airflow, the belt flame spread, and the water spray system in a mine entry. The CFD model was calibrated using test results from a large-scale conveyor belt fire suppression experiment. Simulations were conducted using the calibrated CFD model to investigate the effects of sprinkler location, water flow rate, and sprinkler activation temperature on the suppression of conveyor belt fires. The sprinkler location and the activation temperature were found to have a major effect on the suppression of the belt fire, while the water flow rate had a minor effect.

  8. Numerical modeling of water spray suppression of conveyor belt fires in a large-scale tunnel

    PubMed Central

    Yuan, Liming; Smith, Alex C.

    2015-01-01

    Conveyor belt fires in an underground mine pose a serious life threat to miners. Water sprinkler systems are usually used to extinguish underground conveyor belt fires, but because of the complex interaction between conveyor belt fires and mine ventilation airflow, more effective engineering designs are needed for the installation of water sprinkler systems. A computational fluid dynamics (CFD) model was developed to simulate the interaction between the ventilation airflow, the belt flame spread, and the water spray system in a mine entry. The CFD model was calibrated using test results from a large-scale conveyor belt fire suppression experiment. Simulations were conducted using the calibrated CFD model to investigate the effects of sprinkler location, water flow rate, and sprinkler activation temperature on the suppression of conveyor belt fires. The sprinkler location and the activation temperature were found to have a major effect on the suppression of the belt fire, while the water flow rate had a minor effect. PMID:26190905

  9. Groundwater quality in some villages of Haryana, India: focus on fluoride and fluorosis.

    PubMed

    Meenakshi; Garg, V K; Kavita; Renuka; Malik, Anju

    2004-01-02

    The fluoride concentration in underground water was determined in four villages of Jind district of Haryana state (India) where it is the only source of drinking water. Various other water quality parameters such as pH, electrical conductivity, total dissolved salts, total hardness, total alkalinity as well as sodium, potassium, calcium, magnesium, carbonate, bicarbonate, chloride and sulfate concentrations were also measured. A systematic calculation of correlation coefficients among different physico-chemical parameters was performed. The analytical results indicated considerable variations among the analyzed samples with respect to their chemical composition. Majority of the samples do not comply with Indian as well as WHO standards for most of the water quality parameters measured. The fluoride concentration in the underground water of these villages varied from 0.3 to 6.9 mg/l, causing dental fluorosis among people especially children of these villages. Overall water quality was found unsatisfactory for drinking purposes without any prior treatment except at eight locations out of 60.

  10. 43 CFR 3436.1-1 - Qualified lease proponents.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... farming or materially damage the quantity and quality of the water in surface or underground water systems... exchange bear the burden of establishing that they are qualified pursuant to paragraph (a) of this section...

  11. 43 CFR 3436.1-1 - Qualified lease proponents.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... farming or materially damage the quantity and quality of the water in surface or underground water systems... exchange bear the burden of establishing that they are qualified pursuant to paragraph (a) of this section...

  12. Public Water-Supply Systems and Associated Water Use in Tennessee, 2000

    USGS Publications Warehouse

    Webbers, Ank

    2003-01-01

    Public water-supply systems in Tennessee provide water to meet customer needs for domestic, industrial, and commercial users and municipal services. In 2000, more than 500 public water-supply systems distributed about 890 million gallons per day (Mgal/d) of surface water and ground water to a population of about 5 million in Tennessee. Surface-water sources provided 64 percent (about 569 Mgal/d) of the State?s water supplies, primarily in Middle and East Tennessee. Ground water produced from wells and springs in Middle and East Tennessee and from wells in West Tennessee provided 36 percent (about 321 Mgal/d) of the public water supplies. Springs in Middle and East Tennessee provided about 14 percent (about 42 Mgal/d) of ground-water supplies used in the State. Per capita water use for Tennessee in 2000 was about 136 gallons per day. An additional 146 public water-supply systems provided approximately 84 Mgal/d of water supplies that were purchased from other water systems. Water withdrawals by public water-supply systems in Tennessee have increased by over 250 percent; from 250 Mgal/d in 1955 to 890 Mgal/d in 2000. Although Tennessee public water-supply systems withdraw less ground water than surface water, ground-water withdrawal rates reported by these systems continue to increase. In addition, the number of public water-supply systems reporting ground-water withdrawals of 1 Mgal/d or more in West Tennessee is increasing.

  13. Inter-disciplinary Interactions in Underground Laboratories

    NASA Astrophysics Data System (ADS)

    Wang, J. S.; Bettini, A.

    2010-12-01

    Many of underground facilities, ranging from simple cavities to fully equipped laboratories, have been established worldwide (1) to evaluate the impacts of emplacing nuclear wastes in underground research laboratories (URLs) and (2) to measure rare physics events in deep underground laboratories (DULs). In this presentation, we compare similarities and differences between URLs and DULs in focus of site characterization, in quantification of quietness, and in improvement of signal to noise ratios. The nuclear waste URLs are located primarily in geological medium with potentials for slow flow/transport and long isolation. The URL medium include plastic salt, hard rock, soft clay, volcanic tuff, basalt and shale, at over ~500 m where waste repositories are envisioned to be excavated. The majority of URLs are dedicated facilities excavated after extensive site characterization. The focuses are on fracture distributions, heterogeneity, scaling, coupled processes, and other fundamental issues of earth sciences. For the physics DULs, the depth/overburden thickness is the main parameter that determines the damping of cosmic rays, and that, consequently, should be larger than, typically, 800m. Radioactivity from rocks, neutron flux, and radon gas, depending on local rock and ventilation conditions (largely independent of depth), are also characterized at different sites to quantify the background level for physics experiments. DULs have been constructed by excavating dedicated experimental halls and service cavities near to a road tunnel (horizontal access) or in a mine (vertical access). Cavities at shallower depths are suitable for experiments on neutrinos from artificial source, power reactors or accelerators. Rocks stability (depth dependent), safe access, and utility supply are among factors of main concerns for DULs. While the focuses and missions of URLs and DULs are very different, common experience and lessons learned may be useful for ongoing development of new facilities needed for next generation of underground assessments and experiments. There are growing interests in developing multi-disciplinary programs in DULs and some URLs have rooms set aside for physics experiments. Examples of DULs and URLs with interactions between earth sciences and physics include Gran Sasso in Italy, Kaimioka in Japan, Canfranc in Spain, LSBB in France, WIPP in New Mexico, DUSEL in South Dakota, and Jing Ping deep tunnel underground laboratory proposal in China. Instruments of common interests include interferometers, laser strain meters, seismic networks, tiltmeters, gravimeters, magnetometers, and other sensors to detect signals over different frequencies and water chemical analyses, including radon concentrations. Radon emissions are of concern for physics experiments and are studied as possible precursors of earthquakes. Measuring geoneutrino flux and energy spectrum in different locations is of interests to both physics and earth sciences. The contributions of U and Th in the crust and the mantle to the energy production in the Earth can be studied. One final note is that our ongoing reviews are aimed to contribute to technological innovations anticipated through inter-disciplinary interactions.

  14. Water in Your Community. What We Take from Our Environment. Science and Technology Education in Philippine Society.

    ERIC Educational Resources Information Center

    Philippines Univ., Quezon City. Inst. for Science and Mathematics Education Development.

    This module (recommended for grades 5 or 6) provides information on water in the community. Topics considered include: safe water (showing how clear water may be unsafe to drink); water sources; drinking water and wells; clean water underground; how water gets from the ground to the faucet inside a home; the groundwater of seaside and inland…

  15. Types of hydrogeological response to large-scale explosions and earthquakes

    NASA Astrophysics Data System (ADS)

    Gorbunova, Ella; Vinogradov, Evgeny; Besedina, Alina; Martynov, Vasilii

    2017-04-01

    Hydrogeological response to anthropogenic and natural impact indicates massif properties and mode of deformation. We studied uneven-aged aquifers that had been unsealed at the Semipalatinsk testing area (Kazakhstan) and geophysical observatory "Mikhnevo" at the Moscow region (Russia). Data was collected during long-term underground water monitoring that was carried out in 1983-1989 when large-scale underground nuclear explosions were realized. Precise observations of underground water response to distant earthquakes waves passage at GPO "Mikhnevo" have been conducted since 2008. One of the goals of the study was to mark out main types of either dynamic or irreversible spatial-temporal underground water response to large-scale explosions and to compare them with those of earthquakes impact as it had been presented in different papers. As far as nobody really knows hydrogeological processes that occur at the earthquake source it's especially important to analyze experimental data of groundwater level variations that was carried close to epicenter first minutes to hours after explosions. We found that hydrogeodynamic reaction strongly depends on initial geological and hydrogeological conditions as far as on seismic impact parameters. In the near area post-dynamic variations can lead to either excess pressure dome or depression cone forming that results of aquifer drainage due to rock massif fracturing. In the far area explosion effect is comparable with the one of distant earthquake and provides dynamic water level oscillations. Precise monitoring at the "Mikhnevo" area was conducted in the platform conditions far from active faults thus we consider it as a purely calm area far from earthquake sources. Both dynamic and irreversible water level change seem to form power dependence on vertical peak ground displacement velocity due to wave passage. Further research will be aimed at transition close-to-far area to identify a criterion that determines either irreversible or elastic behavior of hydrogeological response. This work was supported by the Russian Science Foundation (project no. 16-17-00095).

  16. 7 CFR 612.5 - Dissemination of water supply forecasts and basic data.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 6 2010-01-01 2010-01-01 false Dissemination of water supply forecasts and basic data... SUPPLY FORECASTS § 612.5 Dissemination of water supply forecasts and basic data. Water supply outlook reports prepared by NRCS and its cooperators containing water supply forecasts and basic data are usually...

  17. Problems of drinking water treatment along Ismailia Canal Province, Egypt.

    PubMed

    Geriesh, Mohamed H; Balke, Klaus-Dieter; El-Rayes, Ahmed E

    2008-03-01

    The present drinking water purification system in Egypt uses surface water as a raw water supply without a preliminary filtration process. On the other hand, chlorine gas is added as a disinfectant agent in two steps, pre- and post-chlorination. Due to these reasons most of water treatment plants suffer low filtering effectiveness and produce the trihalomethane (THM) species as a chlorination by-product. The Ismailia Canal represents the most distal downstream of the main Nile River. Thus its water contains all the proceeded pollutants discharged into the Nile. In addition, the downstream reaches of the canal act as an agricultural drain during the closing period of the High Dam gates in January and February every year. Moreover, the wide industrial zone along the upstream course of the canal enriches the canal water with high concentrations of heavy metals. The obtained results indicate that the canal gains up to 24.06x10(6) m3 of water from the surrounding shallow aquifer during the closing period of the High Dam gates, while during the rest of the year, the canal acts as an influent stream losing about 99.6x10(6) m3 of its water budget. The reduction of total organic carbon (TOC) and suspended particulate matters (SPMs) should be one of the central goals of any treatment plan to avoid the disinfectants by-products. The combination of sedimentation basins, gravel pre-filtration and slow sand filtration, and underground passage with microbiological oxidation-reduction and adsorption criteria showed good removal of parasites and bacteria and complete elimination of TOC, SPM and heavy metals. Moreover, it reduces the use of disinfectants chemicals and lowers the treatment costs. However, this purification system under the arid climate prevailing in Egypt should be tested and modified prior to application.

  18. Problems of drinking water treatment along Ismailia Canal Province, Egypt*

    PubMed Central

    Geriesh, Mohamed H.; Balke, Klaus-Dieter; El-Rayes, Ahmed E.

    2008-01-01

    The present drinking water purification system in Egypt uses surface water as a raw water supply without a preliminary filtration process. On the other hand, chlorine gas is added as a disinfectant agent in two steps, pre- and post-chlorination. Due to these reasons most of water treatment plants suffer low filtering effectiveness and produce the trihalomethane (THM) species as a chlorination by-product. The Ismailia Canal represents the most distal downstream of the main Nile River. Thus its water contains all the proceeded pollutants discharged into the Nile. In addition, the downstream reaches of the canal act as an agricultural drain during the closing period of the High Dam gates in January and February every year. Moreover, the wide industrial zone along the upstream course of the canal enriches the canal water with high concentrations of heavy metals. The obtained results indicate that the canal gains up to 24.06×106 m3 of water from the surrounding shallow aquifer during the closing period of the High Dam gates, while during the rest of the year, the canal acts as an influent stream losing about 99.6×106 m3 of its water budget. The reduction of total organic carbon (TOC) and suspended particulate matters (SPMs) should be one of the central goals of any treatment plan to avoid the disinfectants by-products. The combination of sedimentation basins, gravel pre-filtration and slow sand filtration, and underground passage with microbiological oxidation-reduction and adsorption criteria showed good removal of parasites and bacteria and complete elimination of TOC, SPM and heavy metals. Moreover, it reduces the use of disinfectants chemicals and lowers the treatment costs. However, this purification system under the arid climate prevailing in Egypt should be tested and modified prior to application. PMID:18357626

  19. Urban community perception towards intermittent water supply system.

    PubMed

    Joshi, M W; Talkhande, A V; Andey, S P; Kelkar, P S

    2002-04-01

    While evaluating intermittent and continuous water supply systems, consumers opinion survey was undertaken for critical appraisal of both modes of operation. With the help of a pre-designed set of questions relating to various aspects of water supply and the opinion of consumers regarding degree of service, a house to house survey was conducted in the study area of Ghaziabad and Jaipur. The consumer opinion survey clearly indicated a satisfactory degree of service wherever adequate quantity of water was made available irrespective of the mode of water supply. Number of complaints regarding quality of water supplied, timings of supply, low pressures and breakdowns in supply were reported during intermittent water supply. Every family stored water for drinking and other uses. Most of the families discard drinking water once the fresh water supply is resumed next day. Discarded drinking water is usually used in kitchen for washing and gardening. Storage for other purposes depends on economic status and availability of other sources like open dug well in the house. While most of the respondents had no complaints on water tariff, all of them were in favour of continuous water supply.

  20. Underground thermal generation of hydrocarbons from dry, southwestern coals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vanderborgh, N.E.; Elliott, G.R.B.

    1978-01-01

    The LASL underground coal conversion concept produces intermediate-BTU fuel gas for nearby industries such as ''minemouth'' electric power plants, plus major byproducts in the form of liquid and gaseous hydrocarbons for feedstocks to chemical plants e.g., substitute natural gas (SNG) producers. The concept involves controlling the water influx and drying the coal, generating hydrocarbons, by pyrolysis and finally gasifying the residual char with O/sub 2//CO/sub 2/ or air/CO/sub 2/ mixtures to produce industrial fuel gases. Underground conversion can be frustrated by uncontrolled water in the coal bed. Moisture can (a) prevent combustion, (b) preclude fuel gas formation by lowering reactionmore » zone temperatures and creating kinetic problems, (c) ruin product gas quality by dropping temperatures into a thermodynamically unsatisfactory regime, (d) degrade an initially satisfactory fuel gas by consuming carbon monoxide, (e) waste large amounts of heat, and (f) isolate reaction zones so that the processing will bypass blocks of coal.« less

  1. 40 CFR 35.918-1 - Additional limitations on awards for individual systems.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...-Clean Water Act § 35.918-1 Additional limitations on awards for individual systems. In addition to those... underground potable water sources; (g) Establish a system of user charges and industrial cost recovery in... as a minimum, periodic testing of water from existing potable water wells in the area. Where a...

  2. 40 CFR 35.918-1 - Additional limitations on awards for individual systems.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...-Clean Water Act § 35.918-1 Additional limitations on awards for individual systems. In addition to those... underground potable water sources; (g) Establish a system of user charges and industrial cost recovery in... as a minimum, periodic testing of water from existing potable water wells in the area. Where a...

  3. 40 CFR 35.918-1 - Additional limitations on awards for individual systems.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...-Clean Water Act § 35.918-1 Additional limitations on awards for individual systems. In addition to those... underground potable water sources; (g) Establish a system of user charges and industrial cost recovery in... as a minimum, periodic testing of water from existing potable water wells in the area. Where a...

  4. 40 CFR 35.918-1 - Additional limitations on awards for individual systems.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...-Clean Water Act § 35.918-1 Additional limitations on awards for individual systems. In addition to those... underground potable water sources; (g) Establish a system of user charges and industrial cost recovery in... as a minimum, periodic testing of water from existing potable water wells in the area. Where a...

  5. 40 CFR 257.3-4 - Ground water.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Ground water. 257.3-4 Section 257.3-4... and Practices § 257.3-4 Ground water. (a) A facility or practice shall not contaminate an underground drinking water source beyond the solid waste boundary or beyond an alternative boundary specified in...

  6. 40 CFR 257.3-4 - Ground water.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 25 2011-07-01 2011-07-01 false Ground water. 257.3-4 Section 257.3-4... and Practices § 257.3-4 Ground water. (a) A facility or practice shall not contaminate an underground drinking water source beyond the solid waste boundary or beyond an alternative boundary specified in...

  7. 30 CFR 77.216 - Water, sediment, or slurry impoundments and impounding structures; general.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Water, sediment, or slurry impoundments and... WORK AREAS OF UNDERGROUND COAL MINES Surface Installations § 77.216 Water, sediment, or slurry... structures which impound water, sediment, or slurry shall be required if such an existing or proposed...

  8. 30 CFR 77.216 - Water, sediment, or slurry impoundments and impounding structures; general.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Water, sediment, or slurry impoundments and... WORK AREAS OF UNDERGROUND COAL MINES Surface Installations § 77.216 Water, sediment, or slurry... structures which impound water, sediment, or slurry shall be required if such an existing or proposed...

  9. 30 CFR 75.1101-10 - Water sprinkler systems; fire warning devices at belt drives.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Water sprinkler systems; fire warning devices..., DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1101-10 Water sprinkler systems; fire warning devices at belt drives. Each water sprinkler...

  10. 30 CFR 75.1101-10 - Water sprinkler systems; fire warning devices at belt drives.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Water sprinkler systems; fire warning devices..., DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1101-10 Water sprinkler systems; fire warning devices at belt drives. Each water sprinkler...

  11. 30 CFR 75.1101-11 - Inspection of water sprinkler systems.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Inspection of water sprinkler systems. 75.1101... COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1101-11 Inspection of water sprinkler systems. Each water sprinkler system shall be examined weekly and a...

  12. 30 CFR 75.1101-11 - Inspection of water sprinkler systems.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Inspection of water sprinkler systems. 75.1101... COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1101-11 Inspection of water sprinkler systems. Each water sprinkler system shall be examined weekly and a...

  13. 30 CFR 75.1101-10 - Water sprinkler systems; fire warning devices at belt drives.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Water sprinkler systems; fire warning devices..., DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1101-10 Water sprinkler systems; fire warning devices at belt drives. Each water sprinkler...

  14. 30 CFR 75.1101-10 - Water sprinkler systems; fire warning devices at belt drives.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Water sprinkler systems; fire warning devices..., DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1101-10 Water sprinkler systems; fire warning devices at belt drives. Each water sprinkler...

  15. 30 CFR 75.1101-11 - Inspection of water sprinkler systems.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Inspection of water sprinkler systems. 75.1101... COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1101-11 Inspection of water sprinkler systems. Each water sprinkler system shall be examined weekly and a...

  16. 30 CFR 75.1101-11 - Inspection of water sprinkler systems.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Inspection of water sprinkler systems. 75.1101... COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1101-11 Inspection of water sprinkler systems. Each water sprinkler system shall be examined weekly and a...

  17. 30 CFR 75.1101-11 - Inspection of water sprinkler systems.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Inspection of water sprinkler systems. 75.1101... COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1101-11 Inspection of water sprinkler systems. Each water sprinkler system shall be examined weekly and a...

  18. 30 CFR 75.1101-10 - Water sprinkler systems; fire warning devices at belt drives.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Water sprinkler systems; fire warning devices..., DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1101-10 Water sprinkler systems; fire warning devices at belt drives. Each water sprinkler...

  19. 40 CFR 257.3-4 - Ground water.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 26 2012-07-01 2011-07-01 true Ground water. 257.3-4 Section 257.3-4... and Practices § 257.3-4 Ground water. (a) A facility or practice shall not contaminate an underground drinking water source beyond the solid waste boundary or beyond an alternative boundary specified in...

  20. 40 CFR 257.3-4 - Ground water.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 26 2013-07-01 2013-07-01 false Ground water. 257.3-4 Section 257.3-4... and Practices § 257.3-4 Ground water. (a) A facility or practice shall not contaminate an underground drinking water source beyond the solid waste boundary or beyond an alternative boundary specified in...

  1. 40 CFR 257.3-4 - Ground water.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 25 2014-07-01 2014-07-01 false Ground water. 257.3-4 Section 257.3-4... and Practices § 257.3-4 Ground water. (a) A facility or practice shall not contaminate an underground drinking water source beyond the solid waste boundary or beyond an alternative boundary specified in...

  2. Influence of water conductivity on shock waves generated by underwater electrical wire explosion

    NASA Astrophysics Data System (ADS)

    Liu, Ben; Wang, Deguo; Guo, Yanbao

    2018-01-01

    The new application of electrical explosion of wire (EEW) used in petroleum industry is to enhance oil recovery (EOR). Because of the complex environment underground, the effect of underground water conductivity on EEW should be considered. This work describes the effect of water conductivities on discharge current, voltage and shock waves. It was found that the effect of water conductivity contains two parts. One is the shunt effect of saline water, which can be considered as a parallel load with the copper wire between the electrodes connected to the discharge circuit. The peak pressure of shock waves are gradually decrease with the increase of water conductivity. The other is the current loss through saline water directly to the ground ends without flowing through the electrodes. The shunt effect is the main factor affecting the wire discharge process. As the charging voltage increased, the energy loss caused by these two parts are all reduced. These indicate that increasing the charging voltage to a certain value will increase the energy efficiency to generate a more powerful shock waves in conductive water.

  3. 40 CFR 135.11 - Service of notice.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ....11 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS PRIOR NOTICE OF CITIZEN SUITS Prior Notice Under the Safe Drinking Water Act § 135.11 Service of notice. (a... water system or underground injection well is alleged to be in violation, service shall be upon the...

  4. 40 CFR 135.11 - Service of notice.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ....11 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS PRIOR NOTICE OF CITIZEN SUITS Prior Notice Under the Safe Drinking Water Act § 135.11 Service of notice. (a... water system or underground injection well is alleged to be in violation, service shall be upon the...

  5. Public-supply water use and self-supplied industrial water use in Tennessee, 2010

    USGS Publications Warehouse

    Robinson, John A.

    2018-04-26

    The U.S. Geological Survey (USGS), in cooperation with the Tennessee Department of Environment and Conservation, Division of Water Resources, prepared this report and displayed and analyzed water use by self-supplied industrial and public-supply water systems in Tennessee for 2010. Public-supply water systems in Tennessee provide water for domestic, industrial, and commercial uses and for municipal services. In 2010, 474 public-supply water systems distributed 917 million gallons per day (Mgal/d) of surface water (67 percent, 617 Mgal/d) and groundwater (33 percent, 300 Mgal/d) to a population of 5.7 million in Tennessee. Gross per capita water use in Tennessee during 2010 was 162 gallons per day.Since 1950, water withdrawals by public-supply water systems in Tennessee have increased from 160 Mgal/d to 917 Mgal/d in 2010. Each of the 95 counties in Tennessee was served by at least 1 public-supply water system in 2010. Tennessee public-supply water systems withdraw less groundwater than surface water, and surface-water use has increased at a faster rate than groundwater use. Since 2005, surface-water withdrawals have increased by 26 Mgal/d, and groundwater withdrawals have decreased by 29 Mgal/d, which is the first decrease in groundwater withdrawals since 1950; however, 29 systems reported increased groundwater withdrawals during 2010, and 12 of these 29 systems reported increases of 1 Mgal/d or more. Davidson County had the largest surface-water withdrawal rate (136 Mgal/d) in 2010. The largest groundwater withdrawal rate (151 Mgal/d) by a single public-supply water system was reported by Memphis Light, Gas and Water, which served more than 669,000 people in Shelby County in 2010.Self-supplied industrial water use includes water for such purposes as fabrication, processing, washing, diluting, cooling, or transporting a product; incorporating water into a product; or for sanitation needs in facilities that manufacture various products. Water withdrawals for self-supplied industrial water use during 2010 were about 776 Mgal/d. This quantity represented a decrease of 7 Mgal/d since 2005. In Tennessee, self-supplied industrial water withdrawals were primarily for chemical and allied products (555 Mgal/d), paper and allied products (107 Mgal/d), aeronautical products (71.5 Mgal/d), concrete and glass products (9.74 Mgal/d), and primary metal products (4.49 Mgal/d); and these products accounted for 96 percent (747 Mgal/d) of the self-supplied industrial water withdrawals in 2010. Surface water supplied 94 percent of the water (728 Mgal/d) for self-supplied industrial purposes, and groundwater supplied 6 percent (47.6 Mgal/d). Self-supplied industrial water withdrawals in Sullivan County were 488 Mgal/d and accounted for 61 percent of the self-supplied industrial water withdrawals. The largest groundwater withdrawal, 14.9 Mgal/d, by a single self-supplied industry was in Memphis, Tennessee, for the production of chemicals and allied products.

  6. Radon in underground waters as a natural analogue to study the escape of CO2 in geological repositories.

    PubMed

    Martín Sánchez, A; Ruano Sánchez, A B; de la Torre Pérez, J; Jurado Vargas, M

    2015-11-01

    Activity concentrations of dissolved (222)Rn and (226)Ra were measured in several underground aquifers, which are candidates for repositories or for the study of analogue natural escapes of CO2. The concentration of both radionuclides in water was determined using liquid scintillation counting. The values obtained for the (222)Rn concentrations varied from 0 to 150 Bq l(-1), while the levels of (226)Ra were in general very low. This indicates that (222)Rn is coming from the decay of the undissolved (226)Ra existing in the rocks and deep layers of the aquifers, being later transported by diffusion in water. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  7. Application of BIM Technology in Building Water Supply and Drainage Design

    NASA Astrophysics Data System (ADS)

    Wei, Tianyun; Chen, Guiqing; Wang, Junde

    2017-12-01

    Through the application of BIM technology, the idea of building water supply and drainage designers can be related to the model, the various influencing factors to affect water supply and drainage design can be considered more comprehensively. BIM(Building information model) technology assist in improving the design process of building water supply and drainage, promoting the building water supply and drainage planning, enriching the building water supply and drainage design method, improving the water supply and drainage system design level and building quality. Combined with fuzzy comprehensive evaluation method to analyze the advantages of BIM technology in building water supply and drainage design. Therefore, application prospects of BIM technology are very worthy of promotion.

  8. Solar heated office complex--Greenwood, South Carolina

    NASA Technical Reports Server (NTRS)

    1981-01-01

    Report contains thorough docuumentation of project meeting 85 percent of building heat requirements. System uses roof mounted recirculating water solar panels and underground hot water energy storage. Aluminum film reflectors increase total solar flux captured by panels.

  9. Migration of carbon dioxide included micro-nano bubble water in porous media and its monitoring

    NASA Astrophysics Data System (ADS)

    Takemura, T.; Hamamoto, S.; Suzuki, K.; Koichi, O.

    2017-12-01

    The distributed CO2 storage is the small scale storage and its located near the emission areas. In the distributed CO2 storage, the CO2 is neutralized by sediment and underground water in the subsurface region (300-500m depth). Carbon dioxide (CO2) included micro-nano bubbles is one approach in neutralizing CO2 and sediments by increasing CO2 volume per unit volume of water and accelerating the chemical reaction. In order to design underground treatment for CO2 gas in the subsurface, it is required to elucidate the behavior of CO2 included micro-nano bubbles in the water. In this study, we carried out laboratory experiment using the soil tank, and measure the amount of leakage of CO2 gas at the surface. In addition, the process of migration of carbon dioxide included micro-nano bubble was monitored by the nondestructive method, wave velocity and resistivity.

  10. Women, water supply and sanitation: INSTRAW's training initiatives.

    PubMed

    Tavares, J

    1997-01-01

    The International Research and Training Institute for the Advancement of Women (INSTRAW) has worked on women, water supply and sanitation since 1986. The program aims to establish the relationship between women, water supply and sanitation and the promotion of the needs of women and their participation in Water Supply and Sanitation projects. Using a multimedia and modular approach, the training package on Women, Water Supply and Sanitation aims to provide an overview for the different government agencies, engineers, trainers and managers involved in water supply and sanitation projects. The six modules contained in this package include: 1) The International Drinking Water Supply and Sanitation Decade and beyond; 2) The Participation of Women in planning, Choice of Technology and Implementation of Sustainable Water Supply and Sanitation Projects; 3) Role of Women in Hygiene Education and Training Activities for Water Supply and Sanitation Projects; 4) Involvement of Women in Management of Water resources, Water Supply and Waste Disposal; 5) Women and Waste Management; and 6) Evaluation and Monitoring of Water Supply and Sanitation Programs, Projects and the Role of Women. In addition, each module comprises five components including objective description, detailed bibliography, feedback tools for each modular unit, lesson plan and guides for trainers and users, and audiovisual aids. In the face of water scarcity, INSTRAW highlights the importance of women¿s participation in the sustainable use of water supply.

  11. [Identifying dry-weather flow and pollution load sources of separate storm sewer systems with different degrees of illicit discharge].

    PubMed

    Meng, Ying-ying; Feng, Cang; Li, Tian; Wang, Ling

    2009-12-01

    Dry-weather flow quantity and quality of three representative separate storm sewer systems in Shanghai-H, G, N were studied. Based on survey of operating status of the pumping stations as well as characteristics of the drainage systems, it was obtained that the interception sewage volumes per unit area in the three systems were 3610 m3/(km2 x d), 1550 m3/(km2 x d), 2970 m3/(km2 x d) respectively; the sanitary wastewater included accounted for 25%, 85% and 71% respectively; the interception volume of H was mainly composed of infiltrated underground water, so the dry-weather flow pollution was slighter, and the interception volumes of G, N were both mainly composed of sanitary wastewater, so the dry-weather which were flow pollution was relatively serious. The water characteristics of potential illicit discharge sources of dry-weather which were flow-grey water, black water and underground water were preliminarily explored, so that treating three parameters-LAS/ NH4+ -N, NH4+ -N/K, Mg/K as tracer parameters of grey water, black water and underground water was put forward. Moreover, the water characteristics of grey water and sanitary wastewater including black water were summarized: the feature of grey water was LAS/NH4+ -N > 0.2, NH4+ -N/K <1, and sanitary wastewater was LAS/NH4+ -N < 0.2, NH4+ -N/K >1. Based on the above, the applications of flow chart method and CMBM method in dry-weather flow detection of monitored storm systems were preliminarily discussed, and the results were basically same as that obtained in flow quantity and quality comprehensive analysis. The research results and methods can provide guidance for analysis and diagnosis of dry-weather flow sources and subsequent reconstruction projects in similar separate storm sewer systems at home.

  12. Application of Electrical Resistivity Method (ERM) in Groundwater Exploration

    NASA Astrophysics Data System (ADS)

    Izzaty Riwayat, Akhtar; Nazri, Mohd Ariff Ahmad; Hazreek Zainal Abidin, Mohd

    2018-04-01

    The geophysical method which dominant by geophysicists become one of most popular method applied by engineers in civil engineering fields. Electrical Resistivity Method (ERM) is one of geophysical tool that offer very attractive technique for subsurface profile characterization in larger area. Applicable alternative technique in groundwater exploration such as ERM which complement with existing conventional method may produce comprehensive and convincing output thus effective in terms of cost, time, data coverage and sustainable. ERM has been applied by various application in groundwater exploration. Over the years, conventional method such as excavation and test boring are the tools used to obtain information of earth layer especially during site investigation. There are several problems regarding the application of conventional technique as it only provides information at actual drilling point only. This review paper was carried out to expose the application of ERM in groundwater exploration. Results from ERM could be additional information to respective expert for their problem solving such as the information on groundwater pollution, leachate, underground and source of water supply.

  13. Comparing microbial water quality in an intermittent and continuous piped water supply.

    PubMed

    Kumpel, Emily; Nelson, Kara L

    2013-09-15

    Supplying piped water intermittently is a common practice throughout the world that increases the risk of microbial contamination through multiple mechanisms. Converting an intermittent supply to a continuous supply has the potential to improve the quality of water delivered to consumers. To understand the effects of this upgrade on water quality, we tested samples from reservoirs, consumer taps, and drinking water provided by households (e.g. from storage containers) from an intermittent and continuous supply in Hubli-Dharwad, India, over one year. Water samples were tested for total coliform, Escherichia coli, turbidity, free chlorine, and combined chlorine. While water quality was similar at service reservoirs supplying the continuous and intermittent sections of the network, indicator bacteria were detected more frequently and at higher concentrations in samples from taps supplied intermittently compared to those supplied continuously (p < 0.01). Detection of E. coli was rare in continuous supply, with 0.7% of tap samples positive compared to 31.7% of intermittent water supply tap samples positive for E. coli. In samples from both continuously and intermittently supplied taps, higher concentrations of total coliform were measured after rainfall events. While source water quality declined slightly during the rainy season, only tap water from intermittent supply had significantly more indicator bacteria throughout the rainy season compared to the dry season. Drinking water samples provided by households in both continuous and intermittent supplies had higher concentrations of indicator bacteria than samples collected directly from taps. Most households with continuous supply continued to store water for drinking, resulting in re-contamination, which may reduce the benefits to water quality of converting to continuous supply. Copyright © 2013 Elsevier Ltd. All rights reserved.

  14. Ecogeochemistry of the subsurface food web at pH 0-2.5 in Iron Mountain, California, U.S.A.

    USGS Publications Warehouse

    Robbins, E.I.; Rodgers, T.M.; Alpers, Charles N.; Nordstrom, D. Kirk

    2000-01-01

    Pyrite oxidation in the underground mining environment of Iron Mountain, California, has created the most acidic pH values ever reported in aquatic systems. Sulfate values as high as 120 000 mg l-1 and iron as high as 27 600 mg l-1 have been measured in the mine water, which also carries abundant other dissolved metals including Al, Zn, Cu, Cd, Mn, Sb and Pb. Extreme acidity and high metal concentrations apparently do not preclude the presence of an underground acidophilic food web, which has developed with bacterial biomass at the base and heliozoans as top predators. Slimes, oil-like films, flexible and inflexible stalactites, sediments, water and precipitates were found to have distinctive communities. A variety of filamentous and non-filamentous bacteria grew in slimes in water having pH values < 1.0. Fungal hyphae colonize stalactites dripping pH 1.0 water; they may help to form these drip structures. Motile hypotrichous ciliates and bdelloid rotifers are particularly abundant in slimes having a pH of 1.5. Holdfasts of the iron bacterium Leptothrix discophora attach to biofilms covering pools of standing water having a pH of 2.5 in the mine. The mine is not a closed environment - people, forced air flow and massive flushing during high intensity rainfall provide intermittent contact between the surface and underground habitats, so the mine ecosystem probably is not a restricted one.

  15. Ecogeochemistry of the subsurface food web at pH 0–2.5 in Iron Mountain, California, U.S.A.

    USGS Publications Warehouse

    Robbins, Eleanora I.; Rodgers , Teresa M.; Alpers, Charles N.; Nordstrom, D. Kirk

    2000-01-01

    Pyrite oxidation in the underground mining environment of Iron Mountain, California, has created the most acidic pH values ever reported in aquatic systems. Sulfate values as high as 120 000 mg l−1 and iron as high as 27 600 mg l−1 have been measured in the mine water, which also carries abundant other dissolved metals including Al, Zn, Cu, Cd, Mn, Sb and Pb. Extreme acidity and high metal concentrations apparently do not preclude the presence of an underground acidophilic food web, which has developed with bacterial biomass at the base and heliozoans as top predators. Slimes, oil-like films, flexible and inflexible stalactites, sediments, water and precipitates were found to have distinctive communities. A variety of filamentous and non-filamentous bacteria grew in slimes in water having pH values <1.0. Fungal hyphae colonize stalactites dripping pH 1.0 water; they may help to form these drip structures. Motile hypotrichous ciliates and bdelloid rotifers are particularly abundant in slimes having a pH of 1.5. Holdfasts of the iron bacterium Leptothrix discophora attach to biofilms covering pools of standing water having a pH of 2.5 in the mine. The mine is not a closed environment – people, forced air flow and massive flushing during high intensity rainfall provide intermittent contact between the surface and underground habitats, so the mine ecosystem probably is not a restricted one.

  16. Potential uses of pumped urban groundwater: a case study in Sant Adrià del Besòs (Spain)

    NASA Astrophysics Data System (ADS)

    Jurado, Anna; Vázquez-Suñé, Enric; Pujades, Estanislao

    2017-09-01

    Urban groundwater has often been over-exploited for industrial uses. Now, this usage tends to be reduced or the resource abandoned due to pollution and/or changes in land use. The use and the subsequent disuse of groundwater has resulted in rising water tables that damage underground structures (e.g., building basements and underground car parks and tunnels), leading to the need for additional pumping in urban areas. In the case of the underground parking lot of Sant Adrià del Besòs (Barcelona, NE Spain), large amounts of urban groundwater are pumped to avoid seepage problems. Can this pumped groundwater be used for other purposes (e.g., drinking water and urban irrigation) instead of wasting this valuable resource? To answer this question, it was necessary to quantify the groundwater recharge and to assess the evolution of groundwater quality. The limiting factor at this study site is the groundwater quality because ammonium and some metals (iron and manganese) are present at high concentrations. Hence, further treatment would be needed to meet drinking water requirements. The pumped groundwater could also be used for supplementing river flow for ecological benefit and/or for mitigating seawater intrusion problems. Currently, only a small amount of this urban groundwater is used for cleaning public areas and watering public gardens. This situation highlighted the urgent need to manage this resource in a responsible and more efficient manner, especially in moments of high water demand such as drought periods.

  17. [Substances transport in an underground river of typical karst watershed during storm events].

    PubMed

    Yang, Ping-Heng; Kuang, Ying-Lun; Yuan, Wen-Hao; Jia, Peng; He, Qiu-Fang; Lin, Yu-Shi

    2009-11-01

    Hydrologic process, turbidity, suspended particles matters (SPM), major cations and TOC concentrations during two storm events in late April 2008 were monitored at Jiangjia Spring which is the outlet of Qingmu Guan underground river system. Scanning electron microscopy (SEM) and energy disperse spectroscopy (EDS) analyses of SPM were also performed in order to investigate the transport characteristics of substances, such as SPM, turbidity and major cations in the underground river of typical karst watershed. The results show that at a single and well-developed karst conduit of Jiangjia Spring, discharge, turbidity, and concentrations of SPM, major cations and TOC respond promptly to the rainfall. The carbonate-derived cations including Ca2+, Mg2+ and Sr2+ are subject to dilution effect during the rising limb of discharge. The elevation in turbidity and SPM concentration is a result of the gradual increase of allochthonous substances (soil) flux input from the surface. Al3+, Fe, Mn, Ba2+ and TOC are concomitant substances of SPM. And their concentrations are ascending with turbid rise. The flux of SPM in diameter > 0.45 microm in the underground river is about 9.7 tons during the events. The bad water quality suggests us that the spring water is unfit to drink without purification during the period of rising and recession time of discharge at Jiangjia Spring. Thus, soil erosion and nutrient losing not only strongly destroy the fragile karst ecological environment, but also lead to non-point source pollution, and seriously threaten the drinking water safety of locals.

  18. 7 CFR 612.6 - Application for water supply forecast service.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 6 2010-01-01 2010-01-01 false Application for water supply forecast service. 612.6... CONSERVATION SERVICE, DEPARTMENT OF AGRICULTURE CONSERVATION OPERATIONS SNOW SURVEYS AND WATER SUPPLY FORECASTS § 612.6 Application for water supply forecast service. Requests for obtaining water supply forecasts or...

  19. Analysis of residual chlorine in simple drinking water distribution system with intermittent water supply

    NASA Astrophysics Data System (ADS)

    Goyal, Roopali V.; Patel, H. M.

    2015-09-01

    Knowledge of residual chlorine concentration at various locations in drinking water distribution system is essential final check to the quality of water supplied to the consumers. This paper presents a methodology to find out the residual chlorine concentration at various locations in simple branch network by integrating the hydraulic and water quality model using first-order chlorine decay equation with booster chlorination nodes for intermittent water supply. The explicit equations are developed to compute the residual chlorine in network with a long distribution pipe line at critical nodes. These equations are applicable to Indian conditions where intermittent water supply is the most common system of water supply. It is observed that in intermittent water supply, the residual chlorine at farthest node is sensitive to water supply hours and travelling time of chlorine. Thus, the travelling time of chlorine can be considered to justify the requirement of booster chlorination for intermittent water supply.

  20. 10 CFR 63.302 - Definitions for Subpart L.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ...; and (5) The lithosphere. Aquifer means a water-bearing underground geological formation, group of formations, or part of a formation (excluding perched water bodies) that can yield a significant amount of ground water to a well or spring. Controlled area means: (1) The surface area, identified by passive...

  1. 10 CFR 63.302 - Definitions for Subpart L.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ...; and (5) The lithosphere. Aquifer means a water-bearing underground geological formation, group of formations, or part of a formation (excluding perched water bodies) that can yield a significant amount of ground water to a well or spring. Controlled area means: (1) The surface area, identified by passive...

  2. Relationships between Private Domestic Wells and Underground Storage Tanks: Evaluation of Mapping and Plume Transport Tool Implementations

    EPA Science Inventory

    Well water from private domestic wells (hereafter private wells) is often not tested as private owners are exempt from sampling requirements of the Safe Drinking Water Act. Numerous incidents of contamination of water in private wells have been reported, however. Potential cont...

  3. 40 CFR 256.50 - Requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... underground sources of drinking water under the authority of section 1442(a)(8)(C) of the Safe Drinking Water... Drinking Water Act (42 U.S.C. 300f et seq.) and with the designation of sole source aquifers under section... recovery and solid waste disposal programs at various installations); (8) Department of Energy (State...

  4. 40 CFR 256.50 - Requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... underground sources of drinking water under the authority of section 1442(a)(8)(C) of the Safe Drinking Water... Drinking Water Act (42 U.S.C. 300f et seq.) and with the designation of sole source aquifers under section... recovery and solid waste disposal programs at various installations); (8) Department of Energy (State...

  5. 40 CFR 256.50 - Requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... underground sources of drinking water under the authority of section 1442(a)(8)(C) of the Safe Drinking Water... Drinking Water Act (42 U.S.C. 300f et seq.) and with the designation of sole source aquifers under section... recovery and solid waste disposal programs at various installations); (8) Department of Energy (State...

  6. 40 CFR 256.50 - Requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... underground sources of drinking water under the authority of section 1442(a)(8)(C) of the Safe Drinking Water... Drinking Water Act (42 U.S.C. 300f et seq.) and with the designation of sole source aquifers under section... recovery and solid waste disposal programs at various installations); (8) Department of Energy (State...

  7. 40 CFR 256.50 - Requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... underground sources of drinking water under the authority of section 1442(a)(8)(C) of the Safe Drinking Water... Drinking Water Act (42 U.S.C. 300f et seq.) and with the designation of sole source aquifers under section... recovery and solid waste disposal programs at various installations); (8) Department of Energy (State...

  8. 30 CFR 817.42 - Hydrologic balance: Water quality standards and effluent limitations.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 3 2011-07-01 2011-07-01 false Hydrologic balance: Water quality standards and effluent limitations. 817.42 Section 817.42 Mineral Resources OFFICE OF SURFACE MINING RECLAMATION AND... STANDARDS-UNDERGROUND MINING ACTIVITIES § 817.42 Hydrologic balance: Water quality standards and effluent...

  9. 30 CFR 817.42 - Hydrologic balance: Water quality standards and effluent limitations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 3 2010-07-01 2010-07-01 false Hydrologic balance: Water quality standards and effluent limitations. 817.42 Section 817.42 Mineral Resources OFFICE OF SURFACE MINING RECLAMATION AND... STANDARDS-UNDERGROUND MINING ACTIVITIES § 817.42 Hydrologic balance: Water quality standards and effluent...

  10. MICROBIAL RESPONSES TO CHEMICAL OXIDATION, SIX-PHASE HEATING, AND STEAM INJECTION TREATMENT IN GROUND WATER

    EPA Science Inventory

    MTBE (methyl tertiary butyl ether) is present at high concentrations in ground water at many sites where gasoline has been spilled from underground storage tanks. In addition, TBA (tertiary butyl alcohol) is also present at high concentrations in many of the same ground waters. ...

  11. 30 CFR 75.1716 - Operations under water.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Operations under water. 75.1716 Section 75.1716... MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Miscellaneous § 75.1716 Operations under water. [Statutory... working section of a mine opened prior to such date, in a manner that requires the construction, operation...

  12. Nevada National Security Site Underground Radionuclide Inventory, 1951-1992: Accounting for Radionuclide Decay through September 30, 2012

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Finnegan, David Lawrence; Bowen, Scott Michael; Thompson, Joseph L.

    This report is an update of report LA-13859-MS (Bowen et al., 2001). In that original report, the underground radionuclide inventory at the Nevada National Security Site (NNSS) was decay corrected to September 23, 1992, the date of the last underground nuclear test at the NNSS. In this report, the inventory is updated to account for the decay of radionuclides over two additional decades (1992-2012) and revised tritium, fission product and actinide inventory figures and tables are presented. The maximum contaminant levels for radionuclides were also updated to Safe Drinking Water Act Maximum Contaminant Levels (MCLs) (CFR, 2013). Also, a numbermore » of minor errata found in the original publication were corrected. An inventory of radionuclides produced by 828 underground nuclear tests conducted at the NNSS by the Lawrence Livermore National Laboratory, the Los Alamos National Laboratory, and the Department of the Defense from 1951 to 1992 includes tritium, fission products, actinides, and activation products. The inventory presented in this report provides an estimate of radioactivity remaining underground at the NNSS after nuclear testing. The original test inventory is decayed to September 30, 2012, and predictions of inventory decay over the subsequent 1000 years are presented. For the purposes of summary and publication, the Los Alamos National Laboratory and Lawrence Livermore National Laboratory authors of this report subdivided the inventory into five areas corresponding to the principal geographic test centers at the NNSS. The five areas roughly correspond to Underground Test Area “Corrective Action Units” (CAUs) for remediation of groundwater. In addition, the inventory is further subdivided for the Yucca Flat region by tests where the working point depth is more than 328 feet (100 meters) above the water table and tests that were detonated below that level. Water levels used were those from the U. S. Department of Energy, Nevada Operations Office (1997), now called the Nevada Field Office. Curie activities and atoms are reported as of September 30, 2012. This inventory is strictly a compilation of the residual radiologic inventory remaining from the underground nuclear tests conducted by Lawrence Livermore National Laboratory, Los Alamos National Laboratory and the Department of the Defense from 1951 to 1992 and does not include radioactivity from other types of nuclear testing (e.g., atmospheric, reactors, rocket engines). A companion classified report (Miller et al., 2002) contains test-specific data for each test performed at the NNSS. This work has been sponsored by the U. S. Department of Energy, National Nuclear Security Administration Nevada Field Office.« less

  13. Drinking water contributes to excessive iodine intake among children in Hebei, China.

    PubMed

    Lv, S; Wang, Y; Xu, D; Rutherford, S; Chong, Z; Du, Y; Jia, L; Zhao, J

    2013-09-01

    In Hebei province, China, over six million people are potentially exposed to excessive iodine through consumption of high iodine underground drinking water and consumption of iodized salt. The aim of this study is to evaluate the contributions of drinking water and iodized salt on children's iodine nutrition in one area of Hebei province in order to refine strategies to correct the excessive iodine intake in these areas. To investigate the relationships between iodine content in water, iodized salt and urinary iodine content (UIC) in children (8-10 years), we randomly sampled three towns with a known median water iodine (MWI) of 150-300 μg/l in Hengshui City, Hebei province and collected water, salt and urine samples. The median UIC was 518.1 μg/l, the overall MWI was 247.0 μg/l, and 83% of children sampled were found to have urinary iodine concentrations higher than the WHO criterion of 300 μg/l. There was a significant and positive correlation between the median UIC of the children and the MWI in the 12 villages where the children lived (Spearman R=0.79, P=0.002), but the UIC was not significantly correlated with the median salt intake (MSI) (Spearman R=-0.17, P=0.6). A multiple linear regression analysis indicated that 68.7% of the variability in median UIC is associated with variability in MWI in the 12 villages. Iodine in drinking water was identified to be the key contributor to this excessive iodine in children indicating that in these areas, intervention should focus on providing alternative drinking water supplies.

  14. Novel ideas for maximising dew collection to aid plant establishment to combat desertification and restore degraded dry and arid lands

    NASA Astrophysics Data System (ADS)

    Kotzen, Benz

    2014-05-01

    This paper focuses on the potential of dew to provide water to plants and potentially to people as well in remote and difficult to reach areas where rainfall and underground water cannot be harvested. The combat of desertification and the restoration of degraded and desertified dry and arid lands has never been more urgent. A key practical component of this strategy is the restoration of habitat with planting. But for habitat and planting to survive there needs to be an adequate supply of water. In most cases providing water to the plant's roots is vital. In some areas where habitats have been destroyed, sufficient water is immediately available, for example through seasonal rainfall, or it can be harvested to concentrate adequate supplies of water to the roots. However, in arid and hyper arid areas, as well as in some dryland areas, a consistent and adequate supply of water cannot be provided by any conventional proven method. Thus, as the need to combat desertification and to restore desertified dry and arid land increases, so the need to find novel methods of establishing and maintaining planting and thus habitat increases. In more traditional land management scenarios this can be achieved through manipulating landform on a micro and macro scale, for example, by creating catchments, thereby collecting precipitation and directing it to the plants. Where this cannot be done, other means of water supply are usually required. Bainbridge (2007) and others have shown that supplying water to plants is possible through a number of traditional methods, for example, using clay pots. But most of these techniques require an introduced source of water, for example, obtained through water harvesting methods or by delivering water to site in tanks and by water bowser. This can work but requires continuous manpower. It is expensive and can be physically prohibitive in areas where access is difficult and/or remote. The concept of using dew to supply water in drylands is not new and numerous studies have been undertaken to investigate past so-called dew collectors and to research the possibilities of using new ones. Most of the historical dew collectors have been disputed as dew collection devices. (Beysens et al 2006, Beysens et al in Kogan and Trahtman 2006, Graf et al 2008.) However, contemporary dew collection has proven possible in those areas that have dew fall. It is generally agreed by researchers, such as Sharan and Beysens in 2007 and Jacobs et al in 2008 after Monteith (1957) that the theoretical maximum dew yield is in the order of 0.8 l/m2/day. Although the exact maximum has never been defined the amounts can yet be significant. However, In most cases the investigations of dew supply in areas where dew is known to precipitate has been undertaken with inclined roof like planar surfaces. However, erecting these planes in remote areas and within difficult terrain makes this kind of collector impractical. Additionally such planar surfaces demand space on the ground which then diminishes the areas of restoration and large collectors require additional plumbing to distribute water to the plants themselves. Thus in order to better supply dew to plants other forms are required. This paper discusses the various ideas and concepts that have been developed for dew collection that have emerged on the market and the novel ideas that have been initiated by the author. The research undertaken investigates biomimetic forms which emulate plant forms such as various cacti and succulents investigating their ability to increase surface area as well as releasing heat like a radiator. Additionally other spiky, needle like forms are investigated as well as animal forms, such as the surface of the Stenocara gracilipes Namibian beetle which collects fog. The research initiated a new strategy for dew collection dividing dew collectors into two types: 1) Passive dew collectors, where nightly collection and delivery is achieved without people, and 2) Semi-passive dew collectors, which require people to collect the dew after it has formed on the dew collector. Bibliography Bainbridge D.A., 2007, 'A Guide for Desert and Dryland Restoration', Island Press. Beysens, D., Milimouk I., Nikolayev, V. S., Berkowicz, S., Muselli, M., Heusinkveld, B., and Jacobs, A. F. G., 2006, 'Comment on "The moisture from the air as water resource in arid region: Hopes, doubt and facts'' by Kogan and Trahtman', Journal of Arid Environments 67 (2006) 343-352. Beysens, D., Muselli, M., Ohayone, C., Berkowicz, S. M., Soyeux, E., Mileta, M., Ortega, P., 2006, 'Application of passive radiative cooling for dew condensation', Energy 31 (2006) 2303-2315. Jacobs, A. F. G., Heusinkveld, B. G. and Berkowicz, S. M., 2008, 'Passive dew collection in a grassland area, The Netherlands', Atmospheric Research 87 (2008) 377-385. Monteith, J.L., 1957. 'Dew', Quarterly Journal of Royal Meteorological Society 83, 322-341. Sharan, G., Beysens, D., and Milimouk-Melnytchouk, I., 2007, 'A study of dew water yields on Galvanized iron roofs in Kothara (North-West India)', Journal of Arid Environments 69 (2007) 259-269.

  15. Where Did the Water Go?: Boyle's Law and Pressurized Diaphragm Water Tanks

    ERIC Educational Resources Information Center

    Brimhall, James; Naga, Sundar

    2007-01-01

    Many homes use pressurized diaphragm tanks for storage of water pumped from an underground well. These tanks are very carefully constructed to have separate internal chambers for the storage of water and for the air that provides the pressure. One might expect that the amount of water available for use from, for example, a 50-gallon tank would be…

  16. 40 CFR 144.87 - How does the identification of ground water protection areas and other sensitive ground water...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 23 2014-07-01 2014-07-01 false How does the identification of ground water protection areas and other sensitive ground water areas affect me? 144.87 Section 144.87 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) UNDERGROUND INJECTION CONTROL PROGRAM Requirements for...

  17. 40 CFR 144.87 - How does the identification of ground water protection areas and other sensitive ground water...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 24 2013-07-01 2013-07-01 false How does the identification of ground water protection areas and other sensitive ground water areas affect me? 144.87 Section 144.87 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) UNDERGROUND INJECTION CONTROL PROGRAM Requirements for...

  18. 40 CFR 144.87 - How does the identification of ground water protection areas and other sensitive ground water...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 22 2010-07-01 2010-07-01 false How does the identification of ground water protection areas and other sensitive ground water areas affect me? 144.87 Section 144.87 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) UNDERGROUND INJECTION CONTROL PROGRAM Requirements for...

  19. 40 CFR 144.87 - How does the identification of ground water protection areas and other sensitive ground water...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 23 2011-07-01 2011-07-01 false How does the identification of ground water protection areas and other sensitive ground water areas affect me? 144.87 Section 144.87 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) UNDERGROUND INJECTION CONTROL PROGRAM Requirements for...

  20. 40 CFR 144.87 - How does the identification of ground water protection areas and other sensitive ground water...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 24 2012-07-01 2012-07-01 false How does the identification of ground water protection areas and other sensitive ground water areas affect me? 144.87 Section 144.87 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) UNDERGROUND INJECTION CONTROL PROGRAM Requirements for...

  1. COST EFFECTIVE SEAWATER DESALINATION WITH FICP ELEMENT ARRAYS - PHASE II

    EPA Science Inventory

    Lack of fresh water hinders economic development, devastates human health, leads to environmental degradation and foments political instability. We obtain our water from limited and unevenly distributed surface and underground freshwater sources. Over withdrawal from these ...

  2. 30 CFR 72.620 - Drill dust control at surface mines and surface areas of underground mines.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... collared and drilled wet, or other effective dust control measures shall be used, when drilling non-water-soluble material. Effective dust control measures shall be used when drilling water-soluble material. ...

  3. 30 CFR 72.620 - Drill dust control at surface mines and surface areas of underground mines.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... collared and drilled wet, or other effective dust control measures shall be used, when drilling non-water-soluble material. Effective dust control measures shall be used when drilling water-soluble material. ...

  4. 30 CFR 72.620 - Drill dust control at surface mines and surface areas of underground mines.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... collared and drilled wet, or other effective dust control measures shall be used, when drilling non-water-soluble material. Effective dust control measures shall be used when drilling water-soluble material. ...

  5. 30 CFR 72.620 - Drill dust control at surface mines and surface areas of underground mines.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... collared and drilled wet, or other effective dust control measures shall be used, when drilling non-water-soluble material. Effective dust control measures shall be used when drilling water-soluble material. ...

  6. 30 CFR 72.620 - Drill dust control at surface mines and surface areas of underground mines.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... collared and drilled wet, or other effective dust control measures shall be used, when drilling non-water-soluble material. Effective dust control measures shall be used when drilling water-soluble material. ...

  7. DETECTING WATER FLOW BEHIND PIPE IN INJECTION WELLS

    EPA Science Inventory

    Regulations of the Environmental Protection Agency require that an injection well exhibit both internal and external mechanical integrity. The external mechanical integrity consideration is that there is no significant fluid movement into an underground source of drinking water ...

  8. Water Pipeline Monitoring and Leak Detection using Flow Liquid Meter Sensor

    NASA Astrophysics Data System (ADS)

    Rahmat, R. F.; Satria, I. S.; Siregar, B.; Budiarto, R.

    2017-04-01

    Water distribution is generally installed through underground pipes. Monitoring the underground water pipelines is more difficult than monitoring the water pipelines located on the ground in open space. This situation will cause a permanent loss if there is a disturbance in the pipeline such as leakage. Leaks in pipes can be caused by several factors, such as the pipe’s age, improper installation, and natural disasters. Therefore, a solution is required to detect and to determine the location of the damage when there is a leak. The detection of the leak location will use fluid mechanics and kinematics physics based on harness water flow rate data obtained using flow liquid meter sensor and Arduino UNO as a microcontroller. The results show that the proposed method is able to work stably to determine the location of the leak which has a maximum distance of 2 metres, and it’s able to determine the leak location as close as possible with flow rate about 10 litters per minute.

  9. Water quality data at selected sites in the Mississippi Valley-type Zn-Pb ore district of upper Silesia, Poland, 1995-97

    USGS Publications Warehouse

    Wirt, Laurie; Motyka, Jacek; Leach, David; Sass-Gustkiewicz, Maria; Szuwarzynski, Marek; Adamczyk, Zbigniew; Briggs, Paul; Meiers, Al

    2003-01-01

    The water chemistry of aquifers and streams in the Upper Silesia Ore District, Poland are affected by their proximity to zinc, lead, and silver ores and by ongoing mining activities that date back to the 11th century. This report presents hydrologic and water-quality data collected as part of a collaborative research effort of the U.S. Geological Survey and the University of Mining and Metallurgy in Cracow, Poland to study Mississippi-Valley-Type lead-zinc deposits. MVT deposits in the Upper Silesia Ore District (Fig. 1) were selected for detailed study because the Polish mining industry allowed access to collect samples from underground mines and mine-land property. Water-quality samples were collected from streams, springs, wells, underground mine seeps and drains; and mine-tailings ponds. Data include field measurements of specific conductance, pH, water temperature, and dissolved oxygen and laboratory analyses of major and minor inorganic constituents and selected trace-element constituents.

  10. The water supply-water environment nexus in salt Intrusion area under the climate change

    NASA Astrophysics Data System (ADS)

    Liu, D.

    2017-12-01

    Water resources are critical problems in in salt Intrusion area for the increasing water supply and water quality deterioration. And the climate change exacerbates these problems. In order to balance the relationship between water supply and water environment requirements, the water supply-water environment nexus should be understood well. Based on the de Saint-Venant system of equations and the convection diffusion equation, which can be used to reflect the laws of water quality, the water supply- water environment nexus equation has be determined. And the nexus is dynamic with the climate change factors. The methods of determined the nexus have then been applied to a case study of the water supply-water environment nexus for the Pearl River Delta in China. The results indicate that the water supply-water environment nexus is trade off each other and are mainly affected by the fresh water flow from the upstream, salt water intrusion will reduce the resilience of the water supply system in this area. Our methods provides a useful framework to quantify the nexus according to the mechanisms of the water quantity and water quality, which will useful freshwater allocation and management in this saltwater intrusion area.

  11. Environmental Assessment: Building 3001 Tinker Air Force Base, Oklahoma

    DTIC Science & Technology

    2008-09-01

    developing a Memorandum of Agreement (MOA) with the SHPO and the Oklahoma Archaeological Survey regarding the potential effects the Proposed Action...3.3.5.4 Electrical System Tinker AFB receives its electrical power from Oklahoma Gas and Electric, which delivers power through a looped 138... gas , with diesel fuel used as the backup supply. The steam line system is primarily underground, with a limited number of lines extending

  12. 33 CFR 203.61 - Emergency water supplies due to contaminated water source.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    .... (5) Loss of water supply is not a basis for assistance under this authority. (6) Water will not be... 33 Navigation and Navigable Waters 3 2010-07-01 2010-07-01 false Emergency water supplies due to... PROCEDURES Emergency Water Supplies: Contaminated Water Sources and Drought Assistance § 203.61 Emergency...

  13. 30 CFR 75.1107-7 - Water spray devices; capacity; water supply; minimum requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Water spray devices; capacity; water supply... Water spray devices; capacity; water supply; minimum requirements. (a) Where water spray devices are... square foot over the top surface area of the equipment and the supply of water shall be adequate to...

  14. The effect of coal-bed methane water on spearmint and peppermint

    USDA-ARS?s Scientific Manuscript database

    Coal bed methane (CBM) is extracted from underground coal seams, flooded with water. In order to reduce the pressure and release the methane, the trapped water needs to be pumped out. The resulting ‘waste water’ is known as coal-bed methane water (CBMW). Major concerns with the use of CBMW are the h...

  15. Water Use Patterns in a Small Oklahoma City During Drought and Implications for Leaking Underground Storage Tanks

    EPA Science Inventory

    The City of Ada Oklahoma obtains water from the Simpson-Arbuckle aquifer located 19 km south of town. During winter the typical water demand is approximately 15,000 m3 per day, while during the drought of 2011 demand more than doubled. In order to understand water use patterns,...

  16. 30 CFR 77.216-1 - Water, sediment or slurry impoundments and impounding structures; identification.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Water, sediment or slurry impoundments and... AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES Surface Installations § 77.216-1 Water, sediment or..., operating, or controlling the structure, shall be located on or immediately adjacent to each water, sediment...

  17. 30 CFR 77.216-1 - Water, sediment or slurry impoundments and impounding structures; identification.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Water, sediment or slurry impoundments and... AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES Surface Installations § 77.216-1 Water, sediment or..., operating, or controlling the structure, shall be located on or immediately adjacent to each water, sediment...

  18. Education & Collection Facility GSHP Demonstration Project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Joplin, Jeff

    The Denver Museum of Nature & Science (DMNS) designed and implemented an innovative ground source heat pump (GSHP) system for heating and cooling its new Education and Collection Facility (ECF) building addition. The project goal was to successfully design and install an open-loop GSHP system that utilized water circulating within an underground municipal recycled (non-potable) water system as the heat sink/source as a demonstration project. The expected results were to significantly reduce traditional GSHP installation costs while increasing system efficiency, reduce building energy consumption, require significantly less area and capital to install, and be economically implemented wherever access to amore » recycled water system is available. The project added to the understanding of GSHP technology by implementing the first GSHP system in the United States utilizing a municipal recycled water system as a heat sink/source. The use of this fluid through a GSHP system has not been previously documented. This use application presents a new opportunity for local municipalities to develop and expand the use of underground municipal recycled (non-potable) water systems. The installation costs for this type of technology in the building structure would be a cost savings over traditional GSHP costs, provided the local municipal infrastructure was developed. Additionally, the GSHP system functions as a viable method of heat sink/source as the thermal characteristics of the fluid are generally consistent throughout the year and are efficiently exchanged through the GSHP system and its components. The use of the recycled water system reduces the area required for bore or loop fields; therefore, presenting an application for building structures that have little to no available land use or access. This GSHP application demonstrates the viability of underground municipal recycled (non-potable) water systems as technically achievable, environmentally supportive, and an efficient system.« less

  19. DUSEL and the future of deep terrestrial microbiology (Invited)

    NASA Astrophysics Data System (ADS)

    Onstott, T. C.; Peters, C. A.; Murdoch, L. C.; Elsworth, D.; Sonnenthal, E. L.; Kieft, T.; Boutt, D. F.; Germanovich, L.; Glaser, S. D.; Wang, H. F.; Roggenthen, B.; Lesko, K.; Cushman, P.; Stetler, L. D.; Bang, S.; Anderson, C.

    2009-12-01

    DUSEL will take advantage of the existing subsurface architecture of the deepest mine in the U.S. to provide a platform for launching new exploration into the deep terrestrial biosphere. Multi-year experiments are currently being designed to delineate the relationships between microbial diversity and activity and hydraulic connectivity, temperature, pressure, strain rate and multiphase fluids. Unlike the physics experiments, which will be located close to the center of the mine, most of these experiments will be located at the periphery in existing tunnels at 100 to 2400 m depth in order to access fluid fill fractures with boreholes. Hydrological models suggest that DUSEL could sample ~100 km3 volume for microbial biogeographic and transport studies. The high-capacity underground water filtration plant used to generate ultrapure water for neutrino detectors will readily supply water for microbiology coring projects reducing microbial contamination. This will be essential for the drilling platform located at 2400 m depth that will drill down to 7+ km and 120oC in search of the upper temperature limit for life. Another advantage of underground coring is that the drilling fluid pressure will be much less than that of the fracture water, which means that when the coring bit intersects a water-filled fracture, the fracture water will flow into the core barrel reducing the contamination of fracture surfaces in the cores. The ultra-low radiation background counting facility to be located at 1475 m depth will potentially enable 106 times improvement in the detection limit for subsurface microbial respiration rates using radioactive tracers. The Coupled Thermal-Hydrological-Mechanical-Chemical-Biological, block-heating experiment will examine how the microbial communities within fractures respond to the increased thermal and fluid flux. The Fracture Processes Facility is not only designed to determine what controls rock strength, but could also determine to what extent subsurface chemoautotrophic activity is regulated by tectonic episodicity. The DUSEL CO2 Facility will investigate how microbial activity is impacted by CO2 injection and whether microbial activity has a significant impact upon long-term sequestration of CO2. These three experiments represent a subset of the integrated suite of experiments planned for the first 5 years, but many more microbial experiments can be accommodated within DUSEL. With its unique experimental assets, km-scale spatial access and multi-decade observational lifetime, DUSEL will usher in the next generation of exploration into the deep terrestrial biosphere and not only reveal the answers to many of its well-hidden secrets, but perhaps to the origin of life itself.

  20. 46 CFR 108.467 - Water supply.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Water supply. 108.467 Section 108.467 Shipping COAST... Fire Extinguishing Systems Foam Extinguishing Systems § 108.467 Water supply. The water supply of a foam extinguishing system must not be the water supply of the fire main system on the unit unless when...

  1. 46 CFR 108.467 - Water supply.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Water supply. 108.467 Section 108.467 Shipping COAST... Fire Extinguishing Systems Foam Extinguishing Systems § 108.467 Water supply. The water supply of a foam extinguishing system must not be the water supply of the fire main system on the unit unless when...

  2. 46 CFR 108.467 - Water supply.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Water supply. 108.467 Section 108.467 Shipping COAST... Fire Extinguishing Systems Foam Extinguishing Systems § 108.467 Water supply. The water supply of a foam extinguishing system must not be the water supply of the fire main system on the unit unless when...

  3. 46 CFR 108.467 - Water supply.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Water supply. 108.467 Section 108.467 Shipping COAST... Fire Extinguishing Systems Foam Extinguishing Systems § 108.467 Water supply. The water supply of a foam extinguishing system must not be the water supply of the fire main system on the unit unless when...

  4. 46 CFR 108.467 - Water supply.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Water supply. 108.467 Section 108.467 Shipping COAST... Fire Extinguishing Systems Foam Extinguishing Systems § 108.467 Water supply. The water supply of a foam extinguishing system must not be the water supply of the fire main system on the unit unless when...

  5. Water Underground

    NASA Astrophysics Data System (ADS)

    de Graaf, I. E. M.

    2014-12-01

    The world's largest accessible source of freshwater is hidden underground. However it remains difficult to estimate its volume, and we still cannot answer the question; will there be enough for everybody? In many places of the world groundwater abstraction is unsustainable: more water is used than refilled, leading to decreasing river discharges and declining groundwater levels. It is predicted that for many regions in the world unsustainable water use will increase in the coming decades, due to rising human water use under a changing climate. It would not take long before water shortage causes widespread droughts and the first water war begins. Improving our knowledge about our hidden water is the first step to prevent such large water conflicts. The world's largest aquifers are mapped, but these maps do not mention how much water these aquifers contain or how fast water levels decline. If we can add thickness and geohydrological information to these aquifer maps, we can estimate how much water is stored and its flow direction. Also, data on groundwater age and how fast the aquifer is refilled is needed to predict the impact of human water use and climate change on the groundwater resource. Ultimately, if we can provide this knowledge water conflicts will focus more on a fair distribution instead of absolute amounts of water.

  6. Nevada National Security Site Groundwater Program

    ScienceCinema

    None

    2018-01-16

    From 1951 to 1992, the Unites States government conducted 828 underground nuclear tests at the Nevada National Security Site. About one-third of these tests occurred near, below or within the water table - the very top portion of the groundwater layer where rock and soil are completely saturated with water. As a result, some groundwater was contaminated. The U.S. Department of Energy (DOE) began exploring the effects of groundwater contamination in the 1970s. Though contamination from underground testing has never been detected on public land, the DOE was committed to developing an advanced, reliable monitoring network that ensures the long-term protection of the public. An intensive groundwater investigation program was launched in 1989.

  7. 76 FR 295 - Proposed Amendments to the Water Quality Regulations, Water Code and Comprehensive Plan To...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-04

    ... endangered (T&E) species. Minimum setbacks from water bodies, wetlands, surface water supply intakes and water supply reservoirs at distances specified in the regulations, and from occupied homes, public buildings, public roads, public water supply wells, and domestic water supply wells as provided by...

  8. Modeling the dynamics of a phreatic eruption based on a tilt observation: Barrier breakage leading to the 2014 eruption of Mount Ontake, Japan

    NASA Astrophysics Data System (ADS)

    Maeda, Yuta; Kato, Aitaro; Yamanaka, Yoshiko

    2017-02-01

    Although phreatic eruptions are common volcanic phenomena that sometimes result in significant disasters, their dynamics are poorly understood. In this study, we address the dynamics of the phreatic eruption of Mount Ontake, Japan, in 2014 based on analyses of a tilt change observed immediately (450 s) before the eruption onset. We conducted two sets of analysis: a waveform inversion and a modified phase-space analysis. Our waveform inversion of the tilt signal points to a vertical tensile crack at a depth of 1100 m. Our modified phase-space analysis suggests that the tilt change was at first a linear function in time that then switched to exponential growth. We constructed simple analytical models to explain these temporal functions. The linear function was explained by the boiling of underground water controlled by a constant heat supply from a greater depth. The exponential function was explained by the decompression-induced boiling of water and the upward Darcy flow of the water vapor through a permeable region of small cracks that were newly created in response to ongoing boiling. We interpret that this region was intact prior to the start of the tilt change, and thus, it has acted as a permeability barrier for the upward migration of fluids; it was a breakage of this barrier that led to the eruption.

  9. 46 CFR 63.25-3 - Electric hot water supply boilers.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Electric hot water supply boilers. 63.25-3 Section 63.25... water supply boilers. (a) Electric hot water supply boilers that have a capacity not greater than 454... section except the periodic testing required by paragraph (j) of this section. Electric hot water supply...

  10. RIVERBANK FILTRATION: EFFECT OF GROUND PASSAGE ON NOM CHARACTER

    EPA Science Inventory

    Research was conducted to explore the effect of underground travel on the character of the natural organic matter (NOM) originating from the river water source during riverbank filtration (RBF) at three Midwestern US drinking water utilities. Measurements of biodegradable dissolv...

  11. Public water supplies of the 100 largest cities of the United States, 1962

    USGS Publications Warehouse

    Durfor, Charles N.; Becker, Edith

    1964-01-01

    The report is divided into two sections. The first describes the uses of water in large cities, the raw-water supplies available for public supplies, tl-<; major and minor constituents and the properties of water, the methods of analyses, the treatment of water, the effects of chemical treatment on constituents and properties of water, and the costs of water treatment. The second is a city-by-city inventory that gives (a) the population of the city, (b) the adjacent communities supplied by the city water system, (c) the total population served, (d) the sources of water supply (including auxiliary and emergency supplies), (e) the average amount of water used daily, (f) the lowest 30-day mean discharge of streams used for public supply during recent years, (g) the treatment of water, (h) the rated capacity of each water-treatment plant, and (i) the storage capacity for raw and finished water. For 58 of the cities, the sources of water, the location of water-treatment plants, and the areas served by the city system are shown on maps. Chemical, spectrographic, and radiochemical analyses of treated water and chemical and spectrographic analyses for many of the raw-water supplies are presented in tabular form.

  12. Effects of inequality of supply hours on consumers' coping strategies and perceptions of intermittent water supply in Kathmandu Valley, Nepal.

    PubMed

    Guragai, B; Takizawa, S; Hashimoto, T; Oguma, K

    2017-12-01

    To investigate the effects of unequal supply hours on consumers' coping strategies and perceptions of the intermittent water supply (IWS) in the Kathmandu Valley (KV), Nepal we conducted a randomized household survey (n=369) and on-site water quality tests. Half of the households received piped water for 6 or fewer hours per week. To augment or cope with the inadequate supply, 28% of the households used highly contaminated and expensive tanker-delivered water. Half of the piped water samples (n=13) were contaminated with Escherichia coli. Free chlorine concentration in all piped water samples was below the national standards (0.1-0.2mg/L), but combined chlorine was detected at an average of 0.24mg/L, indicating ingression of contaminants in the network. Point-of-use devices could increase access to safe water in the KV from 42% to 80%. The use of Lorenz curves and Gini coefficients revealed inequality of piped water supply hours per week both between and within service areas in the KV, due mainly to a small percentage of households who receive longer supply hours. To cope with reduced supply hours, home owners pay more to get water from alternative sources, while tenants compromise their water consumption. Under IWS, expectations for improvements in piped water quality and supply regularity are higher than those for supply volume. Consumers' perceptions of the piped water services worsen with the reduction in supply hours, but perceptions of piped water tariff are independent of supply hours. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. 75 FR 32209 - North San Pablo Bay Restoration and Reuse Project

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-07

    ... Napa counties are facing long-term water supply shortfalls. Surface and groundwater supplies within... water levels and water quality. Recycled water can augment local water supplies on a regional basis... reliability. Additionally, reliable water supply is needed in order to continue the restoration of tidal...

  14. 18 CFR 801.6 - Water supply.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 18 Conservation of Power and Water Resources 2 2010-04-01 2010-04-01 false Water supply. 801.6... POLICIES § 801.6 Water supply. (a) The Susquehanna River Basin is rich in water resources. With proper... forth in the comprehensive plan. (c) The Commission shall study the basin's water supply needs, the...

  15. Assessing the susceptibility to contamination of two aquifer systems used for public water supply in the Modesto and Fresno metropolitan areas, California, 2001 and 2002

    USGS Publications Warehouse

    Wright, Michael T.; Belitz, Kenneth; Johnson, Tyler D.

    2004-01-01

    Ground-water samples were collected from 90 active public supply wells in the Fresno and Modesto metropolitan areas as part of the California Aquifer Susceptibility (CAS) program. The CAS program was formed to examine the susceptibility to contamination of aquifers that are tapped by public supply wells to serve the citizens of California. The objectives of the program are twofold: (1) to evaluate the quality of ground water used for public supply using volatile organic compound (VOC) concentrations in ground-water samples and (2) to determine if the occurrence and distribution of low level VOCs in ground water and characteristics, such as land use, can be used to predict aquifer susceptibility to contamination from anthropogenic activities occurring at, or near, land surface. An evaluation was made of the relation between VOC occurrence and the explanatory variables: depth to the top of the uppermost well perforation, land use, relative ground-water age, high nitrate concentrations, density of leaking underground fuel tanks (LUFT), and source of recharge water. VOCs were detected in 92 percent of the wells sampled in Modesto and in 72 percent of the wells sampled in Fresno. Trihalomethanes (THM) and solvents were frequently detected in both study areas. Conversely, the gasoline components?benzene, toluene ethylbenzene, and xylenes (BTEX)?were rarely, if at all, detected, even though LUFTs were scattered throughout both study areas. The rare occurrence of BTEX compounds may be the result of their low solubility and labile nature in the subsurface environment. Samples were analyzed for 85 VOCs; 25 were detected in at least one sample. The concentrations of nearly all VOCs detected were at least an order of magnitude below action levels set by drinking water standards. Concentrations of four VOCs exceeded federal and state maximum contaminant levels (MCL): the solvent trichloroethylene (TCE) and the fumigant 1, 2-dibromo-3-chloropropane (DBCP) in Fresno, and the solvents TCE and tetrachloroethylene (PCE) in Modesto. Chloroform, which is a by product of water disinfection and a constituent used in industrial processes since the 1920s, was the most frequently detected compound, whereas the gasoline oxygenate methyl tert-butyl ether (MTBE), which has been in widespread production and use only since the 1990s, was detected in only 2 percent of the samples. Downward migration of contaminants appears to be a viable pathway of contamination in the unconfined and semi-confined aquifers underlying the Fresno and Modesto study areas. Within the individual study areas, VOCs were detected more frequently and in greater numbers in shallower wells than in deeper wells. Additionally, VOCs were detected more frequently and in greater numbers in Modesto than in Fresno. Wells sampled in Modesto were significantly shallower than the wells sampled in Fresno; the other explanatory variables examined in this report were not significantly different between the two study areas. VOCs occurred more frequently in younger ground water (water recharged after 1952) than in older ground water (water recharged prior to 1952). Additionally, wells withdrawing younger ground water had a higher number of VOCs detected per well than did wells withdrawing older ground water. Younger ground water was at or near the land surface during a period when VOCs came into widespread production and use. Therefore, wells from which younger ground water is withdrawn may be more susceptible to contamination. Of the explanatory variables examined in this study, land use was the best predictor of aquifer susceptibility in the Fresno and Modesto study areas. VOCs were detected more frequently in wells located in heavily urbanized areas. The number of VOCs detected in ground water was positively correlated to the degree of urbanization. VOCs are produced and used primarily in urban land use settings; therefore, aquifers underlying urban areas may be more susceptible to

  16. Early Earth Science Activities in the Sanford Underground Science and Engineering Laboratory at Homestake

    NASA Astrophysics Data System (ADS)

    Wang, J. S.; Glaser, S. D.; Moore, J. R.; Hart, K.; King, G.; Regan, T.; Bang, S. S.; Sani, R. K.; Roggenthen, W. M.

    2007-12-01

    On July 10, 2007, the former Homestake Mine, Lead, South Dakota, was selected as the development site for the Deep Underground Science and Engineering Laboratory, to become the Sanford Underground Science and Engineering Laboratory at Homestake. Work on refurbishment and certification of the Ross Shaft began in August 2007 to effect pumping of water that had reached the 5000 level in late July. Completion of this work will allow a physics and geosciences laboratory to be constructed on the 4,850 ft level (1,478 m from the surface). Concurrent with reentry operations, several earth science research activities have been initiated. These early activities are as follows: (1) Seismic monitoring system: Accelerometers will be installed in surface boreholes and underground drifts as they become available as a result of the reentry work. (2) Evaluation of the 300 level (91 m), which has multiple locations for horizontal access, is ongoing. This near- surface level, with varying overburden thicknesses, offers excellent opportunities to investigate the "critical zone" in terms of hydrology, ecology, and geochemistry, yielding measurements of both moisture and carbon fluxes to evaluate fluid exchanges with the atmosphere. (3) Water and soil samples were collected in the Ross Shaft as part of the first reentry work. Molecular survey of microbial diversity showed the presence of mesophilic and thermophilic cellulose-degrading microorganisms. (4) Supercritical carbon dioxide injection experiments are being planned that will take advantage of three pairs of existing, nearly vertical, open 8-inch (0.2 m) boreholes that are easily accessible from the Ross Shaft. The candidate holes are located between the 1550 and the 2900 levels and are between 90 to 180 m in length (5) Monitoring of the response of the water during the dewatering operations will be facilitated by the use of existing boreholes. Ultimately, the dewatering operation provide access to the 8000 level (depth of 2,438 m), the deepest level. These five examples of ongoing research activities should provide a basis for many other earth science and engineering investigations at this multilevel facility, which already has extensive underground workings. These examples address different aspects of three main themes identified as important by deep underground research communities: restless earth for geo-science, ground truth for geo-engineering, and dark life for geo-microbiology.

  17. Optimization of Design of Aquifer Storage and Recovery System (ASTR) for Enhanced Infiltration Rate with Reduced Cost at the Coastal Aquifers of South-Western Bangladesh

    NASA Astrophysics Data System (ADS)

    Nawrin, N.; Ahmed, K. M.; Rahman, M. M.

    2016-12-01

    Increasing salinity of natural drinking water sources has been reported as one of the many problems that affect low-income countries. Safe potable water sources in coastal Bangladesh have become contaminated by varying degrees of salinity due to saltwater intrusion, cyclone and storm surges and increased shrimp and crab farming along the coastal areas. This crisis is also exacerbated owing to climate change. The problem of salinity can have serious implications to public health. Here Managed Aquifer Recharge (MAR) has been ascertained as a better solution to overcome the fresh water shortage in the coastal belt of Bangladesh in terms of groundwater quality improvement and supply fresh water even during the dry period. 19 MAR systems have been built and tested in the area for providing community water supply by way of creating freshwater buffer zone in the brackish aquifers through artificial recharge of pond or rooftop rainwater. These existing ASTR schemes consist of sand filtration tank with 4 to 6 large diameter infiltration wells filled with sorted gravel. These larger diameter recharge wells make the construction and maintenance expensive and little difficult for the rural communities. Therefore, modification of design is required for enhancing infiltration rates with reduced costs. As the design of the existing MAR system have confronted some problems, the details of design, construction and performance have been studied from previous investigations and a new modified ASTR scheme has been demonstrated to amplify the infiltration rate along with monitoring scheme. Smaller 4 inch diameter empty recharge wells and PVC screen have been used in the newly developed design. Daily infiltration rate has been increased to 8 to 10 m3/d compared to 4 to 6 m3/d in the old design. Three layered sand filtration tank has been prepared by modification of an abandoned PSF. Time needed for lowering EC to acceptable limits has been found to be significantly lower than the pre-existing systems. Moreover the abstracted water quality is acceptable for drinking in terms of As, Fe and bacteria. In modified ASTR system both injection and monitoring wells are closed with airtight caps, so the stored water in the underground will be protected from cyclonic storm surges as well as remain safe and can be used immediately after disaster.

  18. Evaluation of soil corrosivity and aquifer protective capacity using geoelectrical investigation in Bwari basement complex area, Abuja

    NASA Astrophysics Data System (ADS)

    Adeniji, A. E.; Omonona, O. V.; Obiora, D. N.; Chukudebelu, J. U.

    2014-04-01

    Bwari is one of the six municipal area councils of the Federal Capital Territory (FCT), Abuja with its attendant growing population and infrastructural developments. Groundwater is the main source of water supply in the area, and urbanization and industrialization are the predominant contributors of contaminants to the hydrological systems. In order to guarantee a continuous supply of potable water, there is a need to investigate the vulnerability of the aquifers to contaminants emanating from domestic and industrial wastes. A total of 20 vertical electrical soundings using Schlumberger electrode array with a maximum half current electrodes separation of 300 m was employed. The results show that the area is characterized by 3-6 geoelectric subsurface layers. The measured overburden thickness ranges from 1.0 to 24.3 m, with a mean value of 7.4 m. The resistivity and longitudinal conductance of the overburden units range from 18 to 11,908 Ωm and 0.047 to 0.875 mhos, respectively. Areas considered as high corrosivity are the central parts with ρ < 180 Ωm. The characteristic longitudinal unit conductance was used to classify the area into zones of good (0.7-4.49 mhos), moderate (0.2-0.69 mhos), weak (0.1-0.19 mhos), and poor (<0.1) aquifer protective capacity. Zones characterized by materials of moderate to good protective capacity serve as sealing potential for the underlying hydrogeological system in the area. This study is aimed at delineating zones that are very prone to groundwater contamination from surface contaminants and subsurface soils that are corrosive to utility pipes buried underground. Hence the findings of this work will constitute part of the tools for groundwater development and management and structural/infrastructural development planning of the area.

  19. 30 CFR 75.1101-9 - Back-up water system.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Back-up water system. 75.1101-9 Section 75.1101-9 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1101-9 Back-up water system...

  20. 30 CFR 75.1101-9 - Back-up water system.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Back-up water system. 75.1101-9 Section 75.1101-9 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection § 75.1101-9 Back-up water system...

Top