Tsugawa, C; Nishijima, E; Muraji, T; Yoshimura, M; Tsubota, N; Asano, H
1997-01-01
The authors have designed a coil airway stent using a thermal shape-memory titanium-nickel alloy (SMA) to relieve airway collapse in children. A characteristic of alloy allowed the stent to be enclosed in the thin introducer tube and to position it bronchoscopically in the collapsed airway. When the stent is warmed to 37 to 40 degrees C, it expands to the memorized diameter and stents the airway. In eight rabbits, an experimental model of potentially fatal tracheomalacia was created by fracturing the tracheal cartilages. The stents of 6 mm in diameter and 15 mm in length were placed, and then the stents were recovered to their original shape within 1 minute. All rabbits except one showed no respiratory symptoms during the follow-up period. Results of bronchoscopy performed 6 and 10 months after implantation showed satisfactory patency of the trachea. The rabbits were killed for histological evaluation 6 to 28 months after implantation. The specimens showed little proliferation of granulation and no dislodgement of the stents. This procedure was attempted in two children who had severe bronchomalacia. One 5-year-old patient underwent implantation with a stent of 5 mm in diameter and 25 mm in length into the left main bronchus. The patient was relieved from apneic attacks. The stent was removed 2 years after implantation after a remarkable improvement of ventilation. The other patient with left bronchomalacia, age 1 year 2 months, underwent implantation with a 5-mm x 20-mm stent. The animal experiment and clinical experience indicated that (1) this stent can be easily inserted and removed bronchoscopically, (2) the stent has good tissue compatibility and little interference of mucociliary function, and (3) the SMA stent is a promising therapeutic adjunct in the management of children with severe tracheobronchomalacia.
Zong, Gang-Jun; Jiang, Hai-Bin; Bai, Yuan; Wu, Gang-Yong; Ye, Guang-Ming; Chen, Jing-Kai; Qin, Yong-Wen; Zhao, Xian-xian
2013-12-01
We investigated the effects of percutaneous valved stent implantation in the ascending aorta as an alternative treatment for aortic regurgitation in a canine model. A total of 16 healthy dogs weighing an average of 18.3 ± 2.1 kg were used for the establishment of animal models of chronic aortic regurgitation by percutaneous aortic valve perforation and balloon dilation. At 2 mo after successful model establishment, all experimental animals underwent valved stent implantation in the ascending aorta and then were followed up for 3 mo. Experimental models of chronic aortic regurgitation were successfully established in 10 dogs. Surviving dogs underwent successful valved stent implantation in the ascending aorta and were subsequently followed up for 3 mo. The level of instantaneous aortic regurgitation at 3-mo follow-up was significantly reduced compared with that before valved stent implantation (2.4 ± 0.9 versus 10.6 ± 2.1 mL/s, P < 0.05). The left ventricular ejection fraction was significantly increased (53.8 ± 4.2% versus 37.8 ± 3.7%, P < 0.05), and the left ventricular end-diastolic volume was also significantly reduced (30.3 ± 2.2 versus 40.1 ± 3.6 mL, P < 0.05). No paravalvular leak, stroke, atrioventricular block, or other complications occurred in dogs undergoing valved stent implantation. Percutaneous valved stent implantation in the ascending aorta is feasible, effective, and safe as an alternative treatment for very high-risk aortic regurgitation in a canine model. Copyright © 2013 Elsevier Inc. All rights reserved.
Okuyama, Hidenobu; Hirono, Osamu; Ishigaki, Daisuke; Yuki, Koichi; Kubota, Isao
2010-01-01
A 59-year-old man visited our hospital due to right leg edema and right leg pain. Computed tomography revealed that the circumferential enhancement of bilateral external iliac arteries by soft tissue that had similar density as the adjacent psoas muscle and that the right external iliac vein that was constricted by those tissues. The patient was diagnosed as retroperitoneal fibrosis. He underwent stent implantation to the right external iliac vein stenosis and steroid therapy. His right leg edema and pain was immediately improved after the stent implantation and he achieved remission.
Acute stent thrombosis after a "stroll for fresh air". A case of the smoking gun.
Gotsman, I; Helman, Y; Planer, D
2013-02-01
We present a case of a patient who underwent a percutaneous coronary intervention and excused himself for some "fresh air". He subsequently developed acute stent thrombosis. We discuss the contribution of acute cigarette smoking to this serious complication after stent implantation.
Bor, Renáta; Fábián, Anna; Bálint, Anita; Farkas, Klaudia; Szűcs, Mónika; Milassin, Ágnes; Czakó, László; Rutka, Mariann; Molnár, Tamás; Szepes, Zoltán
2017-08-01
Self-expandable metal stent (SEMS) implantation may rapidly improve the symptoms of malignant esophageal stenosis and tracheoesophageal fistulas (TEF). However, dysphagia often returns subsequently and repeated endoscopic intervention may be necessary. The aims of the study were to identify the risk factors of complications, and the frequency and efficacy of repeated endoscopic interventions; and to provide technical recommendations on appropriate stent selection. We analyzed retrospectively the clinical data of 212 patients with locally advanced esophageal cancer who underwent SEMS implantation. A total of 238 SEMS implantations were performed with 99.06% technical success and 1.26% procedure-related deaths in the enrolled 212 cases. Complications occurred in 84 patients (39.62%) and in 55 cases (25.94%) repeated endoscopic procedures were required. Early reintervention 24-48 h after the stent implantations was necessary due to stent migration (12 cases), arrhythmia (2 cases), intolerable retrosternal pain (1 case) and dyspnea (1 case). An average of 1.98 repeated gastroscopies (range 1-6; median 2), 13.58 weeks (range 1.5-48; median 11) after the stent implantation were performed during the follow-up period: 37 stent repositions, 23 restent implantations, 15 endoscopic esophageal dilations and 7 stent removals. In 48 cases (87.3%) oral feeding of patients was made possible by endoscopic interventions. In a quarter of SEMS implantations, complications occur that can be successfully managed by endoscopic interventions. Our experiences have shown that individualized stent choice may substantially reduce the complications rate and make repeated endoscopic interventions easier.
Horvath, Keith A.; Mazilu, Dumitru; Kocaturk, Ozgur; Li, Ming
2010-01-01
Objective Aortic valves have been implanted on self-expanding (SE) and balloon-expandable (BE) stents minimally invasively. We have demonstrated the advantages of transapical aortic valve implantation (tAVI) under real-time magnetic resonance imaging (rtMRI) guidance. Whether there are different advantages to SE or BE stents is unknown. We report rtMRI guided tAVI in a porcine model using both SE and BE stents, and compare the differences between the stents. Methods Twenty-two Yucatan pigs (45-57kgs.) underwent tAVI. Commercially available stentless bioprostheses (21-25mm) were mounted on either BE platinum-iridium stents or SE nitinol stents. rtMRI guidance was employed as the intraoperative imaging. Markers on both types of stents were used to enhance the visualization in rtMRI. Pigs were allowed to survive and had follow-up MRI scans and echocardiography at 1, 3 and 6 months postoperatively. Results rtMRI provided excellent visualization of the aortic valve implantation mounted on both stent types. The implantation times were shorter with the SE stents (60±14 seconds) than BE (74±18s), (p=0.027). Total procedure time was 31 and 37 minutes respectively (p=0.12). It was considerably easier to manipulate the SE stent during deployment without hemodynamic compromise. This was not always the case with the BE stent and its placement occasionally resulted in coronary obstruction and death. Long-term results demonstrated stability of the implants with preservation of myocardial perfusion and function over time for both stents. Conclusions SE stents were easier to position and deploy thus leading to fewer complications during tAVI. Future optimization of SE stent design should improve clinical results. PMID:20971017
MIGS: therapeutic success of combined Xen Gel Stent implantation with cataract surgery.
Hohberger, Bettina; Welge-Lüßen, Ulrich-Christoph; Lämmer, Robert
2018-03-01
Glaucoma, a common disease in the elderly population, is frequently coexistent with cataract. While the combination of filtration surgery and cataract surgery is a challenging topic with limited success, minimal invasive glaucoma surgery (MIGS), such as Xen Gel Stents, seems to provide promising results. The aim of this study was to investigate the complete and qualified therapeutic success of Xen Gel Stent implantation with (XenPhaco) and without cataract surgery. One hundred and eleven open-angle glaucoma eyes underwent implantation of Xen45 Gel Stent (AqueSys, Inc.) with or without cataract operation. Complete therapeutic success was defined as target intraocular pressure (IOP) < 18 mmHg at any time point within 6 months of follow-up without local antiglaucomatous therapy or further surgical interventions. Qualified success was defined as target IOP <18 mmHg with additional 1-2 local antiglaucomatous eye drops. Failure included all cases with the necessity of at least three local antiglaucomatous eye drops or additional glaucoma surgery. Combined implantation of Xen Gel Stent with cataract surgery was performed in 30 eyes and stand-alone Xen Gel Stent implantation was performed in 81 eyes. A complete therapeutic success was achieved in 46.9% of single Xen Gel Stent implantation, whereas 53.3% was reached with combined XenPhaco. Qualified success was seen in 2.5% in the eyes of the single Xen Gel Stent implantation group and in 3.3% of the combined surgery group. Therapeutic failure rate was 49.4% in the stand-alone group vs 46.7% in the combined group. Data were not significantly different for group and subgroup analyses. Complete and qualified therapeutic success is similar for the combination of Xen Gel Stent implantation with and without cataract surgery in open-angle glaucoma patients. MIGS using Xen Gel Stent can be recommended in situations if glaucoma surgery is indicated besides coexisting cataract.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hautmann, Hubert; Rieger, Johannes; Huber, Rudolf M.
1999-03-15
Purpose: To evaluate the long-term mechanical behavior in vivo of expandable endobronchial wire stents, we imaged three different prostheses in the treatment of tracheobronchial disease. Methods: Six patients with bronchial stenoses (three benign, three malignant) underwent insertion of metallic stents. Two self-expandable Wallstents, two balloon-expandable tantalum Strecker stents and two self-expandable nitinol Accuflex stents were used. Measurements of deformation properties were performed during voluntary cough by means of fluoroscopy, at 1 month and 7-10 months after implantation. The procedures were videotaped, their images digitized and the narrowing of stent diameters calculated at intervals of 20 msec. Results: After stent implantationmore » all patients improved with respect to ventilatory function. Radial stent narrowing during cough reached 53% (Wallstent), 59% (tantalum Strecker stent), and 52% (nitinol Accuflex stent) of the relaxed post-implantation diameter. Stent compression was more marked in benign compared with malignant stenoses. In the long term permanent deformation occurred with the tantalum Strecker stents; the other stents were unchanged. Conclusion: Endobronchial wire stents can be helpful in the treatment of major airway collapse and obstructing bronchial lesions. However, evidence of material fatigue as a possible effect of exposure to recurrent mechanical stress on the flexible mesh tube may limit their long-term use. This seems to be predominantly important in benign bronchial collapse.« less
Chang, Il Soo; Park, Sang Woo; Yun, Ik Jin; Hwang, Jae Joon; Lee, Song Am; Kim, Jun Seok; Chang, Seong-Hwan; Jung, Hong Geun
2011-01-01
Objective We wanted to evaluate the status of self-expandable nitinol stents implanted in the P2 and P3 segments of the popliteal artery in Korean patients. Materials and Methods We retrospectively analyzed 189 consecutive patients who underwent endovascular treatment for stenoocclusive lesions in the femoropopliteal artery from July 2003 to March 2009, and 18 patients who underwent stent placement in popliteal arterial P2 and P3 segments were finally enrolled. Lesion patency was evaluated by ultrasound or CT angiography, and stent fracture was assessed by plain X-rays at 1, 3, 6 and 12 months and annually thereafter. Results At the 1-month follow-up, stent fracture (Type 2) was seen in one limb (up to P3, 1 of 18, 6%) and it was identified in seven limbs at the 3-month follow-up (Type 2, Type 3, Type 4) (n = 1: up to P2; n = 6: P3). At the 6-month follow-up, one more fracture (Type 1) (up to P3) was noted. At the 1-year follow-up, there were no additional stent fractures. Just four limbs (up to P2) at the 2-year follow-up did not have stent fracture. The primary patency was 94%, 61% and 44% at 1, 3 and 6 months, respectively, and the group with stent implantation up to P3 had a higher fracture rate than that of the group that underwent stenting up to P2 (p < 0.05). Conclusion We suggest that stent placement up to the popliteal arterial P3 segment and over P2 in an Asian population can worsen the stent patency owing to stent fracture. It may be necessary to develop a stent design and structure for the Asian population that can resist the bending force in the knee joint. PMID:21430937
Biocorrosion of magnesium alloys: a new principle in cardiovascular implant technology?
Heublein, B; Rohde, R; Kaese, V; Niemeyer, M; Hartung, W; Haverich, A
2003-01-01
Objectives: To develop and test a new concept of the degradation kinetics of newly developed coronary stents consisting of magnesium alloys. Methods: Design of a coronary stent prototype consisting of the non-commercial magnesium based alloy AE21 (containing 2% aluminium and 1% rare earths) with an expected 50% loss of mass within six months. Eleven domestic pigs underwent coronary implantation of 20 stents (overstretch injury). Results: No stent caused major problems during implantation or showed signs of initial breakage in the histological evaluation. There were no thromboembolic events. Quantitative angiography at follow up showed a significant (p < 0.01) 40% loss of perfused lumen diameter between days 10 and 35, corresponding to neointima formation seen on histological analysis, and a 25% re-enlargement (p < 0.05) between days 35 and 56 caused by vascular remodelling (based on intravascular ultrasound) resulting from the loss of mechanical integrity of the stent. Inflammation (p < 0.001) and neointimal plaque area (p < 0.05) depended significantly on injury score. Planimetric degradation correlated with time (r = 0.67, p < 0.01). Conclusion: Vascular implants consisting of magnesium alloy degradable by biocorrosion seem to be a realistic alternative to permanent implants. PMID:12748224
Biocorrosion of magnesium alloys: a new principle in cardiovascular implant technology?
Heublein, B; Rohde, R; Kaese, V; Niemeyer, M; Hartung, W; Haverich, A
2003-06-01
To develop and test a new concept of the degradation kinetics of newly developed coronary stents consisting of magnesium alloys. Design of a coronary stent prototype consisting of the non-commercial magnesium based alloy AE21 (containing 2% aluminium and 1% rare earths) with an expected 50% loss of mass within six months. Eleven domestic pigs underwent coronary implantation of 20 stents (overstretch injury). No stent caused major problems during implantation or showed signs of initial breakage in the histological evaluation. There were no thromboembolic events. Quantitative angiography at follow up showed a significant (p < 0.01) 40% loss of perfused lumen diameter between days 10 and 35, corresponding to neointima formation seen on histological analysis, and a 25% re-enlargement (p < 0.05) between days 35 and 56 caused by vascular remodelling (based on intravascular ultrasound) resulting from the loss of mechanical integrity of the stent. Inflammation (p < 0.001) and neointimal plaque area (p < 0.05) depended significantly on injury score. Planimetric degradation correlated with time (r = 0.67, p < 0.01). Vascular implants consisting of magnesium alloy degradable by biocorrosion seem to be a realistic alternative to permanent implants.
Elective implantation of covered stents for coarctation and recoarctation in adolescents and adults.
Alcibar, Juan; Blanco, Roberto; Fernandez, Luis; Arriola, Josune; Garcia, Koldobika; Peña, Natividad; Inguanzo, Ramón; Voces, Roberto; Castellanos, Enrique; Montes, Pedro M
2013-06-01
Stent implantation is an effective therapy for aortic coarctation and recoarctation. However, in adolescents and adults, aortic wall rupture and dissection can occur, as well as aneurysms during follow-up. In order to reduce these complications, we electively implant covered stents. Since 2005, we have performed the procedure using femoral access in 17 patients (2 adolescents and 15 adults), 16 electively and 1 as a rescue procedure. We used the Mullins technique in all cases, implanting a NuMED(®) covered stent. Good stent apposition was achieved in all 17 procedures; 8 patients required a distal flare. Gradient was reduced from 40 (16) mmHg to 2 (2) mmHg (P<.001) and lumen diameter increased from 4 (2) mm to 19 (3) mm (P<.001). Two exceptional cases are discussed: one patient with aortic wall rupture who underwent a rescue procedure using a stent within a covered stent and another patient with total obstruction and intercostal aneurysm in whom the outcome was fatal at 48 h postprocedure (autopsy is shown). Four-year clinical follow-up included Doppler echocardiography; an additional imaging technique was required in 13 patients. All patients recovered well and there were no complications. Covered stents are effective in treating coarctation and recoarctation in adolescents and adults, are the treatment of choice in patients with complex anatomy, and must be available in the operating room as a rescue device when implanting a conventional stent. Copyright © 2012 Sociedad Española de Cardiología. Published by Elsevier Espana. All rights reserved.
Batyraliev, T A; Fettser, D V; Samko, A N; Sidorenko, B A
2010-01-01
to assess the long-term angiographic and clinical results of percutaneous coronary interventions (PCI) with implantation of the drug-eluting stent (DES) Apollo in patients with stable angina pectoris. The study enrolled 48 patients with stable angina who had been implanted with 59 stents. A follow-up of the patients lasted 12 months. The intervention was successful in 100% patients. Following 12 months, 81.3% of the patients underwent angiography that demonstrated that the vascular diameter decreased by 0.32 +/- 0.45 mm and the rate of restenosis was reduced by only 5.3%. The frequency of evident cardiac complications over 12 months was as high as 11.6%. The DES Apollo provides a way of safely performing PCI, by achieving a high of angiographic success rate. The application of this stent yields long-term good angiographic and clinical results in patients with stable angina pectoris.
Okamoto, Naotaka; Ueda, Hiroshi; Yoshimura, Takahiro; Chamaria, Surbhi; Bhatheja, Samit; Vengrenyuk, Yuliya; Rabiei, Samaneh; Barrientos, Yonandy; Kapur, Vishal; Barman, Nitin; Sweeny, Joseph; Baber, Usman; Mehran, Roxana; Sharma, Samin K; Kini, Annapoorna S
2018-04-15
The aim of the study was to compare the acute outcomes of Absorb bioresorbable vascular scaffolds (BVS) and second-generation drug-eluting stent (DES) implantation in routine clinical practice. There is a paucity of data regarding BVS use in a real-world patient population. The study population comprised 40 consecutive patients who underwent percutaneous coronary intervention (PCI) with BVS implantation at a tertiary-care center in New York, New York between July and December of 2016. An optimal implantation technique including adequate lesion preparation, mandatory postdilation, and optical coherence tomography (OCT) imaging was used in all cases. De novo lesions treated with BVS were compared to lesions treated with DES matched by OCT calcium arc, scaffold/stent size, use of atherectomy device, and lesion postdilation. Acute lumen gain, minimal device area, malapposition, eccentricity, and symmetry index were assessed using OCT. We analyzed OCT images of 40 BVS cases and 40 matching DES cases from 35 and 40 patients, respectively. Compared to the DES group, the BVS group demonstrated similar acute lumen gain, minimal scaffold/stent area, eccentricity index, and symmetry index after PCI. There were fewer malapposed struts detected after BVS implantation; however, malapposition distance and length were not different between the groups. BVS implantation in a real-world patient population with optimal implantation technique resulted in similar stent expansion and better strut apposition compared to DES implantation.
Combined Open and Endovascular Repair for Aortic Arch Pathology
Kang, Woong Chol; Ahn, Tae Hoon; Lee, Kyung Hoon; Moon, Chan Il; Han, Seung Hwan; Park, Chul-Hyun; Park, Kook-Yang; Kang, Jin Mo; Kim, Jung Ho
2010-01-01
Background and Objectives We describe our experience with combined open and endovascular repair in patients who have aortic arch pathology. Subjects and Methods This study is a retrospective analysis of 7 patients who underwent combined open and endovascular repair for aortic arch pathology. Medical records and radiographic information were reviewed. Results A total of 7 consecutive patients (5 men, 71.4%) underwent thoracic stent graft implantation. The mean age was 59.9±16.7 years. The indication for endovascular repair was aneurysmal degeneration in 5 patients, and rupture or impending rupture in 2 patients. In all 7 cases, supra-aortic transposition of the great vessels was performed successfully. Stent graft implantation was achieved in all cases. Surgical exposure of the access vessel was necessary in 2 patients. A total of 9 stent grafts were implanted (3 stent grafts in one patient). The Seal thoracic and the Valiant endovascular stent graft were implanted in 6 patients and 1 patient, respectively. There were no post-procedure deaths or neurologic complications. In 2 patients, bleeding and injury of access vessel were noted after the procedure. Postoperative endoleak was noted in 1 patient. One patient died at 10 months after the procedure due to a newly developed ascending aortic dissection. No patients required secondary intervention during the follow-up period. The aortic diameter decreased in 4 patients. In 3 patients, including 1 patient with endoleak, there was no change in aortic diameter. Conclusion Our experience suggests that combined open and endovascular repair for aortic arch pathology is safe and effective, with few complications. PMID:20830254
Sim, Doo Sun; Jeong, Myung Ho; Cha, Kyoung Rae; Park, Suk Ho; Park, Jong Oh; Shin, Young Min; Shin, Heungsoo; Hong, Young Joon; Ahn, Youngkeun; Schwartz, Robert S; Kang, Jung Chaee
2012-12-01
Chronic total occlusion (CTO) remains a challenge in interventional cardiology. We investigated the feasibility and reliability of copper wire stents and levo-polylactic acid (l-PLA) as a means of CTO induction in a porcine model. In one group of 20 swine, copper stents were crimped on a 3.0mm angioplasty balloon and inserted into the mid-left anterior descending coronary artery (LAD). In the other group of 20 swine, l-PLA was wrapped on a guidewire and pushed into the distal LAD with a 3.0mm balloon catheter to induce embolization. Of 20 swine which underwent copper stent implantation, 13 died of stent thrombosis. In the remaining 7 swine, total or near total occlusion with collateral circulation was observed at 5 weeks. Of 20 swine which underwent l-PLA embolization, 4 died of ventricular fibrillation during or shortly after the procedure. Serial histopathologic studies showed complete absorption of the polymer with replacement by fibrotic tissue approximately 4 weeks following the polymer implantation. CTO could be reliably induced in porcine coronary arteries by copper stents and l-PLA. These models may support investigation of new percutaneous devices to facilitate CTO interventions. Copyright © 2012 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.
Neumann, C; Gschwendtner, M; Karnel, F; Mair, J; Dorffner, G; Dorffner, R
2005-01-01
To evaluate the technical feasibility of the implantation of the monorail RX Herculink system into the renal arteries without pre-dilatation. Forty-two patients (mean age 71 years) from four centers with a total of 44 renal artery stenoses underwent implantation of the RX Herculink stent. The mean grade of the stenosis was 83.8 %, the mean length 7.5 mm. The stenoses were ostial in 38 cases and in immediate proximity to the ostium in 6 cases. The mean follow-up-period was 57 weeks (24 - 176 weeks). In 42 cases, the implantation was successful without pre-dilatation. In 2 cases, pre-dilatation was carried out. In none of the cases, detachment of the stent from the balloon was observed. In one stenosis with a length of 17 mm, implantation of two stents was performed. In 9 cases, post-dilatation with a larger balloon or higher balloon pressure was necessary. Residual stenoses exceeding 30 % were not observed. Two patients developed local bleeding at the puncture site. During the follow-up, restenoses were observed in 5 stents after 26 to 126 weeks, which necessitated a second intervention in 3 cases (PTA in 2 cases, re-stenting in 1 case). The primary patency rate after 6 and 12 months was 0.92 +/- 0.056 according to Kaplan-Meier, the secondary patency rate after 6 and 12 months was 1.0 +/- 0.0. Implantation of the RX Herculink stent system into the renal arteries without pre-dilatation is technically feasible and safe. Even without pre-dilatation, the stent-system can be advanced through the stenosis without detachment. The complication rate is low. Our clinical results are comparable to previous studies.
Haji Zeinali, Ali Mohammad; Sadeghian, Mohammad; Qureshi, Shakeel A; Ghazi, Payam
2017-09-01
Endovascular treatment of coarctation of aorta (CoA) by self-expandable Nitinol stents is one of the recognized treatment methods and may be an alternative to surgery or balloon-expandable stent implantation for CoA but there is little information about midterm to long term results of self-expandable stents. Sixty-two patients with CoA (40 men), with a mean age of 30.7 ± 11 years, (range 17-63 years) underwent stent implantation with Optimed self-expandable Nitinol stents between 2005 and 2014. Successful outcome was defined as peak systolic pressure gradient ≤20 mmHg after stent implantation. The patients were followed-up clinically and by echocardiography and in patients, in whom there was suspicion of recoarctation, CT angiography or recatheterization was performed. 65 stents were successfully implanted in all 62 patients. Peak systolic pressure gradient decreased from mean 62.4 ± 18 mmHg (range 35-100 mmHg) to mean 2.8 ± 5 mmHg (range 0-15 mmHg; P < 0.001). Stent displacement occurred in 3 patients during the procedure. These were managed successfully by an overlapping second stent. None of the patients had major complications such as aortic dissection, rupture, or vascular access problems. In follow up, only three patients had recoarctation, and two of these were managed successfully by balloon redilation or further stenting 16 and 18 months after the first procedure and one patient refused reintervention. There were two deaths, unrelated to the procedure, 12 and 78 months after the initial intervention. Follow-up of a mean of 45.5 ± 17 months (range 12-105 months) demonstrated no evidence of aneurysm formation or stent fracture. Self-expandable nitinol stents for the treatment of native and recurrent CoA is safe and has good efficacy with acceptable midterm to long-term outcome. © 2017 Wiley Periodicals, Inc.
Previous coronary stent implantation and cardiac events in patients undergoing noncardiac surgery.
Cruden, Nicholas L M; Harding, Scott A; Flapan, Andrew D; Graham, Cat; Wild, Sarah H; Slack, Rachel; Pell, Jill P; Newby, David E
2010-06-01
Noncardiac surgery performed after coronary stent implantation is associated with an increased risk of stent thrombosis, myocardial infarction, and death. The influence of stent type and period of risk still have to be defined. We linked the Scottish Coronary Revascularisation Register with hospital admission data to undertake a Scotland-wide retrospective cohort study examining cardiac outcomes in all patients who received drug-eluting or bare-metal stents between April 2003 and March 2007 and subsequently underwent noncardiac surgery. Of 1953 patients, 570 (29%) were treated with at least 1 drug-eluting stent and 1383 (71%) with bare-metal stents only. There were no differences between drug-eluting and bare-metal stents in the primary end point of in-hospital mortality or ischemic cardiac events (14.6% versus 13.3%; P=0.3) or the secondary end points of in-hospital mortality (0.7% versus 0.6%; P=0.8) and acute myocardial infarction (1.2% versus 0.7%; P=0.3). Perioperative death and ischemic cardiac events occurred more frequently when surgery was performed within 42 days of stent implantation (42.4% versus 12.8% beyond 42 days; P<0.001), especially in patients revascularized after an acute coronary syndrome (65% versus 32%; P=0.037). There were no temporal differences in outcomes between the drug-eluting and bare-metal stent groups. Patients undergoing noncardiac surgery after recent coronary stent implantation are at increased risk of perioperative myocardial ischemia, myocardial infarction, and death, particularly after an acute coronary syndrome. For at least 2 years after percutaneous coronary intervention, cardiac outcomes after noncardiac surgery are similar for both drug-eluting and bare-metal stents.
Vesga, Boris; Hernandez, Hector; Moncada, Miguel; Gasior, Pawel; Higuera, Sergio; Dager, Antonio; Arana, Camilo; Delgado, Juan A; Généreux, Philippe; Maehara, Akiko; Granada, Juan F
2017-03-01
Bioresorbable polymer drug-eluting stent technologies have been considered to have the potential to enhance vascular healing by reducing polymer exposure to the vessel wall, potentially allowing the earlier discontinuation of dual antiplatelet therapy. At present, the early vascular healing response to this type of technologies is still unclear. The TIMELESS study is a multicenter, prospective, single-arm study that enrolled real-world patients undergoing percutaneous coronary intervention. All patients underwent Synergy stent implantation, which consists of a platinum-chromium platform coated with an ultra-thin abluminal bioabsorbable poly-D,L-lactide-co-glycolide polymer-eluting everolimus. A total of 37 patients were included in the study. The majority of the patients underwent percutaneous coronary intervention because of acute coronary syndromes. At 3 months, angiographic follow-up showed a percentage diameter of stenosis of 8.1±7.5% and an angiographic late loss of 0.03±0.24 mm. In all analyzed struts, less than 1% of struts were definitely uncovered or covered with fibrin, 12.5% (5.0-18.5%) showed evidence of partial coverage, and the remaining (∼85%) were fully covered. No stent thrombosis was observed up to 12 months of clinical follow-up. In a real-world population, the implantation of a bioresorbable polymer drug-eluting stent resulted in almost complete strut coverage throughout the entire stent length at 3 months. The clinical implications for antiplatelet therapy and outcomes should be investigated further.
Kobayashi, Daisuke; Gowda, Srinath T; Forbes, Thomas J
2014-08-01
A 9-year-old male, with history of pulmonary atresia and ventricular septal defect, status post complete repair with a 16 mm pulmonary homograft in the right ventricular outflow tract (RVOT) underwent 3110 Palmaz stent placement for conduit stenosis. Following deployment the stent embolized proximally into the right ventricle (RV). We undertook the choice of repositioning the embolized stent into the conduit with a transcatheter approach. Using a second venous access, the embolized stent was carefully maneuvered into the proximal part of conduit with an inflated Tyshak balloon catheter. A second Palmaz 4010 stent was deployed in the distal conduit telescoping through the embolized stent. The Tyshak balloon catheter was kept inflated in the RV to stabilize the embolized stent in the proximal conduit until it was successfully latched up against the conduit with the deployment of the overlapping second stent. One year later, he underwent Melody valve implantation in the pre-stented conduit relieving conduit insufficiency. This novel balloon assisted two-stents telescoping technique is a feasible transcatheter option to secure an embolized stent from the RV to the RVOT. © 2014 Wiley Periodicals, Inc.
Mauri, Giovanni; Michelozzi, Caterina; Melchiorre, Fabio; Poretti, Dario; Tramarin, Marco; Pedicini, Vittorio; Solbiati, Luigi; Cornalba, Gianpaolo; Sconfienza, Luca Maria
2013-12-01
To evaluate feasibility, safety, and outcome of patients treated with biodegradable biliary stents for benign biliary stenosis refractory to other treatments. Between March 2011 and September 2012, ten patients (seven men, three women; age 59 ± 7 years) with recurrent cholangitis due to postsurgical biliary stricture, previous multiple unsuccessful (two to five) bilioplasties, and unsuitability for surgical/endoscopic repair underwent percutaneous implantation of a biodegradable biliary stent. Patients were followed-up clinically and with ultrasound at 1, 3 and 6 months, and then at 6-month intervals. Stent implantation was always feasible. No immediate major or minor complications occurred. In all patients, 48-h cholangiographic control demonstrated optimal stent positioning and stenosis resolution. In a median follow-up time of 16.5 months (25th-75th percentiles = 11-20.25 months) no further invasive treatment was needed. Three patients experienced transient episodes of cholangitis. Neither re-stenosis nor dilatation of the biliary tree was documented during follow-up. No stent was visible at the 6-month follow-up. Percutaneous placement of biodegradable biliary stents represents a new option in treating benign biliary stenoses refractory to treatment with bilioplasty. This technique seems to be feasible, effective and free from major complications. Further investigations are warranted to confirm our preliminary results.
NASA Astrophysics Data System (ADS)
Karanasos, Antonios; Ligthart, Jurgen; Witberg, Karen; Toutouzas, Konstantinos; Daemen, Joost; van Soest, Gijs; Gnanadesigan, Muthukaruppan; van Geuns, Robert-Jan; de Jaegere, Peter; Regar, Evelyn
2013-03-01
Purpose: Neoatherosclerosis within a stent has been recently described as a culprit of late stent failure. We investigated by optical coherence tomography (OCT) the association of neoatherosclerotic plaque morphology with neointimal rupture (NR) and clinical presentation in patients late after coronary stent implantation. Methods: From 1/1/2007 to 31/1/2012, 74 patients from two institutions underwent OCT assessment of a coronary stent implanted at least 18 months prior to OCT study. Native atherosclerosis criteria were used for neointimal characterization. Results: Neoatherosclerosis was observed in 59.5% of the stents (n=44). Stents with neoatherosclerosis were more often associated with symptoms compared to stents without neoatherosclerosis (59.1% acute coronary syndrome (ACS), 25% stable angina (SA), and 15.9% asymptomatic versus 43.3% ACS, 6.7% SA, 50% asymptomatic, p<0.01). Among neoatherosclerotic lesions (n=44), NR was detected in 19 (43.2%) and had higher incidence in ACS (61.5%) than in SA (18.2%) and asymptomatic (14.3%) (p<0.05). Thrombus was detected in all NR cases. Fibrous cap thickness was lower in NR lesions compared to lesions without NR (48+/-21 μm versus 104+/-58μm, p<0.01). Lipid content tended to be higher in lesions with NR (260+/-103° versus 203+/-85°, p=0.051). Lesions with NR had more often dense macrophage infiltration (84.2% versus 44.0%, p<0.05). There were no differences in neovascularization or calcifications between lesions with or without NR. Conclusions: Neoatherosclerosis is frequent and more common among symptomatic patients. Importantly, neointimal rupture is associated with ACS late after stent implantation. Specific morphological characteristics, such as cap thickness and macrophage infiltration are associated with rupture of neoatherosclerotic plaques.
Goltz, Jan P; Ritter, Christian O; Kellersmann, Richard; Klein, Detlef; Hahn, Dietbert; Kickuth, Ralph
2012-06-01
To evaluate efficacy, safety, and midterm patency of a helical, self-expanding nitinol stent after failed percutaneous transluminal angioplasty (PTA) of popliteal artery segments P1 and P2 in patients with chronic critical limb ischemia (CLI) or lifestyle-limiting claudication. Between February 2009 and March 2011, 40 patients (23 men; mean age 77±10 years) classified as Rutherford category 3 (n = 10) or 4/5 (n = 30) underwent PTA of the proximal and mid popliteal artery followed by implantation of a SUPERA stent for elastic recoil, residual stenosis, or flow-limiting dissection. All patients had an elevated operative risk. Before and after the procedure and during the 12-month follow-up, a clinical investigation, ankle-brachial-index (ABI) measurement, and color-coded duplex sonography and/or digital subtraction angiography were performed. Primary endpoints were limb salvage and anatomical patency at 12 months. Stent implantation was successful in all patients. The major complication rate was 7.5% (an access-site pseudoaneurysm, 2 retroperitoneal hematomas, and 1 death from retroperitoneal bleeding). Mean follow-up was 15.9 months (range 0.5-27.9). The mean baseline ABI of 0.37 significantly increased to 0.91 at 12 months (p<0.01). Three (7.5%) patients underwent bypass surgery owing to lack of clinical improvement (<0.10 improvement in ABI). Primary and secondary patency rates at 12 months in the 34 patients eligible for follow-up were 68.4% and 79.8%, respectively. The major amputation rate was 5% at 1 year. Five (12.5%) in-stent stenoses and 1 of 2 (5.0%) in-stent occlusions were successfully recanalized (the second occlusion was asymptomatic). Implantation of this helical stent into segments of the popliteal artery at the knee joint in CLI patients is a safe and clinically effective bailout method with acceptable intermediate patency.
Konishi, Hirokazu; Miyauchi, Katsumi; Dohi, Tomotaka; Tsuboi, Shuta; Ogita, Manabu; Naito, Ryo; Kasai, Takatoshi; Tamura, Hiroshi; Okazaki, Shinya; Isoda, Kikuo; Daida, Hiroyuki
2016-04-01
The aim of this study is to compare first- and new-generation drug-eluting stents (DESs) which are implanted in long lesion. Stent length is known to be a predictor of adverse events after percutaneous coronary intervention (PCI), even with the first-generation DESs. The introduction of new-generation DESs has reduced the rates of adverse clinical events. However, the impact of stent length on long-term clinical outcomes is not well known. A total of 1181 consecutive patients who underwent PCI using either a first-generation DES (n = 885) or a new-generation DES (n = 296) between 2004 and 2011 were investigated. In each of the stent groups, the patients were divided into two groups by stent length (>32 and ≤32 mm) and compared. During the follow-up period, the incidence of major adverse cardiac events (MACEs) was significantly higher for patients with long stents implanted than with short stents (P < 0.01; log-rank test) in the first-generation DES group. However, there was no difference in the incidence of MACEs between the long- and short-stent groups in the new-generation DES group (P = 0.24; log-rank test). On multivariate Cox regression analysis, stent length was not associated with adverse events in the new-generation DES groups [hazard ratio (HR) 0.87; 95 % confidence interval (95 % CI) 0.71-1.04; P = 0.14]. Implanted stent length was significantly associated with a higher risk of MACEs in patients who received first-generation DESs, but not in patients who received the new-generation DESs.
Fiber-reinforced silicone for tracheobronchial stents: An experimental study.
Vearick, Samanta Bianchi; Demétrio, Kétner Bendo; Xavier, Rogério Gastal; Moreschi, Alexandre Heitor; Muller, André Frotta; Sanches, Paulo Roberto Stefani; Dos Santos, Luis Alberto Loureiro
2018-01-01
A trachea is a tubular structure composed of smooth muscle that is reinforced with cartilage rings. Some diseases can cause sagging in smooth muscle and cartilaginous tissue. The end result is reduction (narrowing) of the trachea diameter. A solution to this problem is the use of tracheal stents, which are small tubular devices made of silicone. One is inserted into the trachea to prevent or correct its constriction. The purpose of tracheal stent use is to maintain cartilage support that would otherwise be lost in the airway. Current tracheal stent models present limitations in terms of shape and characteristics of the silicone used in their production. One of the most important is the large thickness of the wall, which makes its placement difficult; this mainly applies to pediatric patients. The wall thickness of the stent is closely related to the mechanical properties of the material. This study aims to test the reinforcement of silicone with three kinds of fibers, and then stents that were produced using fiber with the best compressive strength characteristics. Silicone samples were reinforced with polypropylene (PP), polyamide (PA), and carbon fiber (CF) at concentrations of 2% and 4% (vol%), which then underwent tensile strength and Shore A hardness testing. Samples with fiber showed good characteristics; surface analyses were carried out and they were used to produce stents with an internal diameter of 11 or 13mm and a length of 50mm. Stents underwent compression tests for qualitative evaluation. Samples with 2% and 4% CF blends showed the best mechanical performance, and they were used to produce stents. These samples presented similar compressive strengths at low deformation, but stents with a 4% CF blend exhibited improved compressive strength at deformations greater than 30-50% of their diameter (P ≤ 0.05). The addition of 2% and 4% CF blends conferred greater mechanical strength and resistance to the silicone matrix. This is particularly true at low deformation, which is the condition where the stent is used when implanted. In the finite element compression strength tests, the stent composite showed greater compression strength with the addition of fiber, and the results were in accordance with mechanical compression tests performed on the stents. In vivo tests showed that, after 30 days of post-implantation in sheep trachea, an inflammatory process occurred in the region of the trachea in contact with the stent composite and with the stent without fiber (WF). This response is a common process during the first few days of implantation. Copyright © 2017 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miyayama, Shiro, E-mail: s-miyayama@fukui.saiseikai.or.jp; Yamashiro, Masashi; Takeda, Taro
We report the successful management of acute cholecystitis using cystic duct stent placement in 3 patients with inoperable malignant cystic duct obstruction (2 cholangiocarcinoma and 1 pancreatic carcinoma). All patients underwent stent placement in the bile duct, using an uncovered stent in 2 and a covered stent in 1, to relieve jaundice occurring 8-184 days (mean 120 days) before the development of acute cholecystitis. The occluded cystic duct was traversed by a microcatheter and a stent was implanted 4-17 days (mean 12 days) after cholecystostomy. Acute cholecystitis was improved after the procedure in all patients. Two patients died 3 andmore » 10 months later, while 1 has survived without cholecystitis for 22 months after the procedure to date.« less
Jakob, H.; Oelert, H.; Schmiedt, W.; Teusch, P.; Iversen, S.; Hake, U.; Schild, H.; Maass, D.
1989-01-01
Fourteen patients with complicated venous thrombosis or recurrent pulmonary embolism were treated by implantation of an endoluminal spiral prosthesis subsequent to balloon angioplasty, surgical thrombectomy or embolectomy, a combination of these, or, in 2 cases, no other treatment. The patients were divided into 2 groups, based on their primary diagnosis and the purpose of the prosthesis. Group I included 8 patients with extensive iliofemoral or caval thrombosis, caused by congenital caval stenosis (1 case) or extravascular compression or retraction (7 cases); 7 of these patients had had previous operations, and the remaining patient had undergone thrombolysis, which failed. The current treatment consisted of balloon angioplasty and surgical thrombectomy or embolectomy, and implantation of an endoluminal spiral stent to prevent elastic recoil of the vessel. In 4 cases, an arteriovenous fistula was constructed and was taken down 3 months later; in 1 additional patient, a bilateral arteriovenous fistula was created. Group II comprised 6 patients with recurrent pulmonary embolism (4 cases), massive pulmonary embolism (1 case), or paradoxical bilateral carotid artery embolism (1 case). Four of these patients underwent surgical thrombectomy or embolectomy, while 2 had no treatment other than filter implantation. All 6 underwent transluminal implantation of a helix caval filter (a modification of the endoluminal spiral stent). All but 1 implantation was accomplished by means of either a transfemoral or a transjugular cutdown; the remaining implantation was performed transatrially after a pulmonary embolectomy. The only device-related complication was a retroperitoneal hematoma in Group I, resulting from perforation of the inferior vena cava by the guidewire during device implantation. This complication necessitated an emergency laparotomy and takedown of the arteriovenous fistula, which resulted in rethrombosis of the left iliofemoral vein. The other 7 stented veins were patent at early phlebographic follow-up, as were all 5 of those studied later. One Group-I patient died 4 months after surgery, due to tumor progression and without signs of caval restenosis. Twelve months postoperatively, 1 Group-II patient died of urosepsis without a recurrence of pulmonary embolism. Four of the 6 Group-II patients were studied late postoperatively, and all of their stented vessels were patent. There was no operative mortality or postoperative embolism. On the basis of these results, we conclude that endoluminal stenting with an expandable spiral prosthesis is a promising method for remote venous reconstruction. Moreover, it appears that the modified stent, or helix caval filter, compares favorably with commercially available filters. (Texas Heart Institute Journal 1989;16:87-94) Images PMID:15227219
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang Zhongmin, E-mail: wzm0722@hotmail.com; Huang Xunbo, E-mail: huangxunbo0722@hotmail.com; Cao Jun, E-mail: caojun88888@hotmail.com
Objective: This study was designed to compare the clinical effectiveness of intraluminal radioactive stent loaded with iodine-125 seeds implantation versus covered stent alone insertion in patients with malignant esophageal stricture. Methods: We studied two groups of patients with malignant esophageal stricture. Group A comprised 28 patients (19 men and 9 women) who underwent intraluminal radioactive stent loaded with iodine-125 seeds implantation and were followed prospectively. Group B comprised 30 patients (18 men and 12 women) who had previously received covered stent alone insertion; these patients were evaluated retrospectively. There was no crossover between the two groups during follow-up. Informed consentmore » was obtained from each patient, and our institutional review board approved the study. The dysphagia score, overall survival rates, complication rates, and reintervention rates were compared in the two groups. Results: There were no significant differences between the two groups in terms of baseline characteristics. Stent placement was technically successful and well tolerated in all patients. The dysphagia score was improved in both groups after stent placement. The median survival was significantly longer in group A than in group B: 11 versus 4.9 months, respectively (P < 0.001). The complications of chest pain, esophageal reflux, and stent migration was more frequent in group B, but this difference did not reach statistical significance. There was no statistical difference in reintervention between two groups. Conclusions: Intraluminal radioactive stent loaded with iodine-125 seeds implantation was a feasible and practical management in treating malignant esophageal stricture and was superior to covered stent alone insertion, as measured by survival.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ichihashi, Shigeo, E-mail: shigeoichihashi@yahoo.co.jp; Higashiura, Wataru; Itoh, Hirofumi
2012-12-15
We report a case of stent fracture and collapse of balloon-expandable stents caused by shiatsu massage. A 76-year-old man presented with complaints of intermittent claudication of the right lower extremity. Stenoses of the bilateral common iliac arteries (CIAs) were detected. Balloon-expandable stents were deployed in both CIAs, resulting in resolution of symptoms. Five months later, pelvis x-ray showed collapse of both stents. Despite the stent collapse, the patient was asymptomatic, and his ankle brachial index values were within the normal range. Further history showed that the patient underwent daily shiatsu therapy in the umbilical region, which may have triggered collapsemore » of the stent. Physicians should advise patients to avoid compression of the abdominal wall after implantation of a stent in the iliac artery.« less
Ishimaru, Hideki; Nakashima, Kazuaki; Takahata, Hideaki; Matsuoka, Yohjiro
2013-02-01
Although stenting for stenotic vertebral artery dissection (VAD) improves compromised blood flow, subsequent peri-stent aneurysm (PSA) formation is not well-known. We report two cases with PSA successfully treated with coil embolization. Three patients with stenotic intracranial VAD underwent endovascular angioplasty at our institution because they had acute infarction in posterior circulation territory and clinical evidence of hemodynamic insufficiency. In two of three patients balloon angioplasty at first session failed to relieve the stenosis, and a coronary stent was implanted. Angiography immediately after stenting showed no abnormality in case 1 and minimal slit-like projection at proximal portion of the stent in case 2. Angiography obtained 16 months after the stenting revealed PSA in case 1. In case 2, angiography performed 3 months later showed that the projection at proximal portion enlarged and formed an aneurysm outside the stent. Because follow-up angiographies showed growth of the aneurysm in both cases, endovascular aneurysmal embolization was performed. We advanced a microcatheter into the aneurysm through the strut of existing stent and delivered detachable coils into the aneurysm lumen successfully in both cases. The post-procedural course was uneventful, and complete obliteration of aneurysm was confirmed on angiography in both cases. Stenting for stenotic intracranial VAD may result in delayed PSA; therefore, follow-up angiographies would be necessary after stenting for stenotic intracranial arterial dissection. Coil embolization through the stent strut would be a solution for enlarging PSA.
Outcome and management of pacemaker-induced superior vena cava syndrome.
Fu, Hai-Xia; Huang, Xin-Miao; Zhong, Li; Osborn, Michael J; Bjarnason, Haraldur; Mulpuru, Siva; Zhao, Xian-Xian; Friedman, Paul A; Cha, Yong-Mei
2014-11-01
We aimed to determine the long-term outcomes of percutaneous lead extraction and stent placement in patients with pacemaker-induced superior vena cava (SVC) syndrome. The study retrospectively screened patients who underwent lead extraction followed by central vein stent implantation at Mayo Clinic (Rochester, MN, USA), from January 2005 to December 2012, to identify the patients with pacemaker-induced SVC syndrome. Demographic, clinical, and follow-up characteristics of those patients were collected from electronic medical records. Six cases were identified. The mean (standard deviation) age was 56 (15) years (male, 67%). All patients had permanent dual-chamber pacemakers, with a mean 11-year history of pacemaker placement. The entire device system was explanted in five patients; one patient had a 21-year-old pacemaker lead that could not be removed. Eight stents were implanted in six patients: five patients had one stent, one patient had three. A new pacemaker system was reimplanted through the stented vein in five patients. Technical success was achieved in all patients, without any complication. Symptoms rapidly resolved in all patients after stent deployment. The mean follow-up duration was 48 months (range, 10-100 months). Three patients remained symptom free. Reintervention with percutaneous balloon venoplasty was successful in three patients with symptom recurrence. Percutaneous stent implantation after lead removal followed by reimplantation of leads is a feasible alternative therapy for pacemaker-induced SVC syndrome, although some cases may require repeat intervention. ©2014 Wiley Periodicals, Inc.
Dvir, Danny; Kitabata, Hironori; Barbash, Israel M; Minha, Sa'ar; Badr, Salem; Loh, Joshua P; Chen, Fang; Torguson, Rebecca; Waksman, Ron
2014-09-01
To evaluate the axial integrity of different coronary stents using intravascular ultrasound (IVUS). Longitudinal stent deformation was recently reported. Consecutive patients who underwent IVUS analysis after drug-eluting stent (DES) implantation for de novo coronary lesions were evaluated. Stent length was compared with label length for calculation of absolute change and relative difference (absolute change divided by label length). A total of 233 DES utilizing five different platforms were included. The median absolute change in stent length was 0.90 mm (interquartile range [IQR] 0.48-1.39) and the relative difference was 5.24% (IQR 2.55-8.29). There was no significant difference among the groups in median absolute or relative change: Cypher 0.89 mm/3.89%, Taxus 0.88 mm/5.39%, Endeavor 1.16 mm/6.77%, Xience V 0.86 mm/5.80%, and PROMUS Element 0.79 mm/5.34% (P = 0.085, P = 0.072, respectively). Multivariate logistic regression revealed that the Cypher stent was independently correlated with a lower change in length, whereas stent label length and deployment pressure were correlated with higher absolute change. The axial integrity of DES platforms examined in vivo was high, with only mild changes in stent length after implantation. While there are differences between first- and second-generation DES, axial integrity among second-generation DES was similar. © 2013 Wiley Periodicals, Inc.
Cheon, Young Koog; Lee, Tae Yoon; Sung, In Kyung; Shim, Chan Sup
2014-01-01
Most delivery devices used for esophageal stents for obstructing esophageal cancer have a diameter of 5-8 mm, a size that is too large to pass through the endoscopic working channel. The conventional esophageal stent requires multiple endoscopic procedures for implantation. The purpose of the present study was to evaluate the clinical feasibility of a newly developed fully covered, self-expanding, through-the-scope (TTS) esophageal stent in a porcine model. Eight mini pigs were used. Each animal underwent placement of a fully covered TTS stent (Hanarostent® Esophagus TTS) and the upper part of the stent was fixed by suturing with nylon. Fluoroscopy was carried out every week to assess migration of the stent. Follow-up endoscopy was done every month for 3 months to evaluate the status of the membrane, stent mesh, grade of tissue hyperplasia, and mucosal changes at both ends of the stent. All stents were successfully and easily deployed, and were placed without any distortion in the stent or without rupture of the membrane. In two cases, stent migration was observed after 8 weeks. No case of membrane disruption, stent mesh disruption or tissue hyperplasia at either end of the stent was found at the completion of the study. Our findings indicate that the new fully covered self-expanding TTS esophageal stent is easy and simple to implant, and no significant distortion of mesh or disruption of membrane was observed. © 2013 The Authors. Digestive Endoscopy © 2013 Japan Gastroenterological Endoscopy Society.
Newly designed "pieced" stent in a rabbit model of benign esophageal stricture.
Liu, Jin; Shang, Liang; Liu, Ji-Yong; Qin, Cheng-Yong
2015-07-28
To investigate a newly designed stent and its dilatation effect in a rabbit model of benign esophageal stricture. Thirty-four New Zealand white rabbits underwent a corrosive injury in the middle esophagus for esophageal stricture formation. Thirty rabbits with a successful formation of esophageal strictures were randomly allocated into two groups. The control group (n = 15) was implanted with a conventional stent, and the study group (n = 15) was implanted with a detachable "pieced" stent. The study stent (30 mm in length, 10 mm in diameter) was composed of three covered metallic pieces connected by surgical suture lines. The stent was collapsed by pulling the suture lines out of the mesh. Two weeks after stricture formation, endoscopic placement of a conventional stent or the new stent was performed. Endoscopic extraction was carried out four weeks later. The extraction rate, ease of extraction, migration, complications, and survival were evaluated. Stent migration occurred in 3/15 (20%) animals in the control group and 2/15 (13%) animals in the study group; the difference between the two groups was not statistically significant. At the end of four weeks, the remaining stents were successfully extracted with the endoscope in 100% (11/11) of the animals in the study group, and 60% (6/10) of the animals in the control group; this difference was statistically significant (P < 0.05). There was no difference in the mean number of follow-up days between the control and study groups (25.33 vs 25.85). Minor bleeding was reported in five cases in the study group and four in the control group. There were no severe complications directly associated with stent implantation or extraction in either of the two groups. In this experimental protocol of benign esophageal strictures, the novel "pieced" stent demonstrated a superior removal rate with a similar migration rate compared to a conventional stent.
Acute lower extremity paralysis after lower extremity endovascular intervention.
Öztürk, Semi; Kalyoncuoğlu, Muhsin; Durmuş, Gündüz; Topçu, Adem; Can, Mehmet
2017-04-01
A 61-year-old man underwent successful percutaneous revascularization of both lower limbs with multiple stent implantations. Paralysis of right lower limb was noticed after completion of procedure when transferring the patient from angiography table. Since hematoma compressing lumbosacral neural plexus could be a fatal complication, computed tomography (CT) image was taken. CT showed bulge of distended bladder compressing stent struts. Following placement of Foley catheter, condition improved and he was subsequently discharged uneventfully.
Boudjemline, Younes
2018-01-01
To describe a new modification, the one-step procedure, that allows interventionists to pre-stent and implant a Melody valve simultaneously. Percutaneous pulmonary valve implantation (PPVI) is the standard of care for managing patients with dysfunctional right ventricular outflow tract, and the approach is standardized. Patients undergoing PPVI using the one-step procedure were identified in our database. Procedural data and radiation exposure were compared to those in a matched group of patients who underwent PPVI using the conventional two-step procedure. Between January 2016 and January 2017, PPVI was performed in 27 patients (median age/range, 19.1/10-55 years) using the one-step procedure involving manual crimping of one to three bare metal stents over the Melody valve. The stent and Melody valve were delivered successfully using the Ensemble delivery system. No complications occurred. All patients had excellent hemodynamic results (median/range post-PPVI right ventricular to pulmonary artery gradient, 9/0-20 mmHg). Valve function was excellent. Median procedural and fluoroscopic times were 56 and 10.2 min, respectively, which significantly differed from those of the two-step procedure group. Similarly, the dose area product (DAP), and radiation time were statistically lower in the one-step group than in the two-step group (P < 0.001 for all variables). After a median follow-up of 8 months (range, 3-14.7), no patient underwent reintervention, and no device dysfunction was observed. The one-step procedure is a safe modification that allows interventionists to prestent and implants the Melody valve simultaneously. It significantly reduces procedural and fluoroscopic times, and radiation exposure. © 2017 Wiley Periodicals, Inc.
Dan, D T; Gannavarapu, B; Lee, J G; Chang, K; Muthusamy, V R
2014-08-01
With the recent availability of removable esophageal stents, endoscopic stenting has been utilized to treat refractory benign esophageal strictures (RBES). The objective of this study was to review the feasibility and effectiveness of removable esophageal stents to treat RBES. Patients who received removable esophageal stents for the treatment of RBES at the institution between 2004-2010 using its stent implantation logs and endoscopic database were retrospectively identified. Patient demographics, stricture etiology and location, stent and procedure characteristics, and clinical outcomes were obtained. Twenty-five patients with a mean age of 70 (72% male) underwent initial stent placement; 24 were successful. Overall clinical success was achieved in five of the 19 patients (26%) ultimately undergoing stent removal. RBES etiologies included anastomotic (13), radiation (5), peptic (3), chemotherapy (1), scleroderma (1), and unknown (2). Alimaxx-E (Merit-Endotek, South Jordan, UT, USA) stents were placed in 20 patients and Polyflex (Boston Scientific, Natick, MA, USA) stents were used in five patients. Immediate complications included failed deployment (1) and chest pain (7). Five patients died prior to stent removal. Stent migration was found in 53% (10/19) of patients who underwent stent removal: nine required additional therapy and one had symptom resolution. Out of the nine patients without stent migration, five required additional therapy and four had symptom resolution. Although placement of removable esophageal stents for RBES is technically feasible, it is frequently complicated by stent migration and chest pain. In addition, few patients achieved long-term stricture resolution after initial stenting. In this study, most patients ultimately required repeated stenting and/or dilations to maintain relief of dysphagia. © 2012 Copyright the Authors. Journal compilation © 2012, Wiley Periodicals, Inc. and the International Society for Diseases of the Esophagus.
Park, S W; Hong, M K; Lee, C W; Kim, J J; Park, H K; Cho, G Y; Kang, D H; Song, J K; Park, S J
2000-08-01
The GFX stent is a balloon-expandable stent made of sinusoidal element of stainless steel. The adjunct high-pressure balloon dilatations were usually recommended in routine stenting procedure. The aim of this study was to evaluate the immediate and long-term clinical and angiographic outcomes and to investigate the necessity of high-pressure balloon dilatation during GFX stenting. In all, 172 consecutive patients underwent single 12 or 18 mm GFX stent implantation in 188 native coronary lesions. Two types of stenting technique were used: (1) stent size of a final stent-to-artery ratio of 1:1 (inflation pressure > 10 atm, high-pressure group), and (2) stent size of 0.5 mm bigger than reference vessel (inflation pressure < or = 10 atm, low-pressure group). The adjunct high-pressure balloon dilatations were performed only in cases of suboptimal results. The adjunct high-pressure balloon dilatation was required in 11 of 83 lesions (13%) in the high-pressure group and in 7 of 105 lesions (7%) in the low-pressure group (p = 0.203). Procedural success rate was 100%. There were no significant differences of in-hospital and long-term clinical events between the two groups. The overall angiographic restenosis rate was 17.7%; 18.4% in the high-pressure group and 17.1% in the low-pressure group (p = 0.991). The GFX stent is a safe and effective device with a high procedural success rate and favorable late clinical outcome for treatment of native coronary artery disease. Further randomized trials may be needed to compare stenting techniques in GFX stent implantation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vajda, Zsolt, E-mail: Z.Vajda@klinikum-stuttgart.de; Guethe, Thomas, E-mail: T.Guethe@klinikum-stuttgart.de; Perez, Marta Aguilar, E-mail: M.Aguilar@klinikum-stuttgart.de
Stenting in intracranial atherosclerotic disease (ICAD) is increasingly debated, due to issues of procedural safety, technical efficacy, and in-stent recurrent stenoses (ISR). In the present study, feasibility, safety, and efficacy of angioplasty using a drug-eluting balloon (DEB) followed by the implantation of a self-expanding stent (Enterprise) were evaluated for the treatment of ICAD lesions. Fifty-two patients (median age: 71 years; range: 54-86 years; male/female ratio 37:15) underwent stenting of high-grade ICAD lesions between February 2010 and November 2011 in a single center. Angioplasty using a paclitaxel coated SeQuent Please (B. Braun, Germany) or DIOR (Eurocor, Germany) coronary PTCA balloon, followedmore » by the implantation of a self-expanding stent (Enterprise, Codman, USA) was performed in 54 lesions. Angiographic and clinical follow-up was performed at 6 and 12 weeks, 6 and 12 months, and yearly thereafter. Technical success rate, periprocedural complications, occurrence of recurrent ischemic symptoms, and the development of an ISR were analyzed. Angioplasty using a DEB followed by stent implantation was successfully performed in 44 (81 %) cases. DEB insertion failed in 19 % of the cases and angioplasty was finally performed using a conventional PTCA balloon. The combined procedure related permanent neurologic morbidity and mortality rate (stroke, ICH, and subarachnoid hemorrhage) at 30 days and beyond was 5 %. Angiographic and clinical follow-up were obtained in 33 (61 %) lesions in 32 patients. Recurrent stenosis was seen in one (3 %) lesion. Angioplasty and stenting using a DEB is safe and yields encouragingly low ISR rates. Further technical developments to improve lesion accessibility are, nevertheless, mandatory.« less
Zurera, L J; Espejo, J J; Canis, M; Bueno, A; Vicente, J; Gilbert, J J
2014-01-01
To retrospectively analyze the safety and efficacy of transjugular intrahepatic portosystemic shunting (TIPS) using covered stents in children. We present 6 children (mean age, 10.6 years; mean weight, 33.5kg) who underwent TIPS with 8mm diameter Viatorr(®) covered stents for acute (n=4) or recurrent (n=2) upper digestive bleeding that could not be controlled by endoscopic measures. Five of the children had cirrhosis and the other had portal vein thrombosis with cavernous transformation. We analyzed the relapse of upper digestive bleeding, the complications that appeared, and the patency of the TIPS shunt on sequential Doppler ultrasonography or until transplantation. A single stent was implanted in a single session in each child; none of the children died. The mean transhepatic gradient decreased from 16mmHg (range: 12-21mmHg) before the procedure to 9mmHg (range: 1-15mmHg) after TIPS. One patient developed mild encephalopathy, and the girl who had portal vein thrombosis with cavernous transformation developed an acute occlusion of the TIPS that resolved after the implantation of a coaxial stent. Three children received transplants (7, 9, and 10 months after the procedure, respectively), and the patency of the TIPS was confirmed at transplantation. In the three remaining children, patency was confirmed with Doppler ultrasonography 1, 3, and 5 months after implantation. None of the children had new episodes of upper digestive bleeding during follow-up after implantation (mean: 8.1 months). Our results indicate that TIPS with 8mm diameter Viatorr(®) covered stents can be safe and efficacious for the treatment of upper digestive bleeding due to gastroesophageal varices in cirrhotic children; our findings need to be corroborated in larger series. Copyright © 2011 SERAM. Published by Elsevier Espana. All rights reserved.
Fu, Yandong; Zhang, Shaotao; Du, Hongwei; Li, Lulu; Wang, Chao; Zheng, Gonghui; Wang, Yan; Dong, Hui; Jia, Haibo; Yu, Bo
2018-04-01
Previous studies have indicated that stent implantation could alter the vessel geometry, which may impact the neointimal healing process. Curvature is an important parameter for evaluating vessel geometry. The purpose of our study was to investigate the relationship between vessel curvature and neointimal healing after stent implantation. Fifty-nine patients with acute coronary syndrome (ACS) who underwent stent implantation were enrolled in the study. According to the post-percutaneous coronary intervention vessel curvature measured by quantitative coronary angiography, patients were divided into high (n = 30) and low (n = 29) curvature groups. Neointimal thickness and area together with the neointimal type were assessed by optical coherence tomography at a 6-month follow-up. Baseline clinical characteristics were comparable between the 2 groups. The vessel curvature at pre- and 6-month follow-up was significantly higher in the high curvature group than the low curvature group. At 6-month follow-up, neointimal thickness (0.22 [0.08-0.32] mm vs. 0.10 [0.07-0.16] mm, P = .043) and neointimal area (1.86 [0.66-2.66] vs. 0.82 [0.60-1.41] mm, P = .030) were significantly higher in the high curvature group than the low curvature group. In the high curvature group, the incidence of the heterogeneous neointimal type was higher than that in the low curvature group (50.00% vs. 17.20%, respectively, P = .004), whereas the frequency of the homogeneous neointimal type was lower (43.30% vs. 82.80%, respectively, P = .004) in the high curvature group than the low curvature group. Higher vessel curvature after stent implantation may potentially have an impact on the neointimal healing with a higher incidence of heterogeneous neointimal.
Vesga, Boris; Hernandez, Hector; Higuera, Sergio; Gasior, Pawel; Echeveri, Dario; Delgado, Juan A; Dager, Antonio; Arana, Camilo; Simonton, Charles; Maehara, Akiko; Palmaz, Julio; Granada, Juan F
2017-01-01
Objective To evaluate the biological effect of microengineered stent grooves (MSG) on early strut healing in humans by performing optical coherence tomography (OCT) analysis 3 weeks following the implantation. Background In the experimental setting, MSG accelerate endothelial cell migration and reduce neointimal proliferation compared with bare metal stent (BMS). Methods A total of 37 patients undergoing percutaneous coronary intervention with de novo coronary lesions were randomly assigned to either MSG (n=19) or an identical BMS controls (n=18). All patients underwent OCT imaging at 3 weeks. A total of 7959 struts were included in the final analysis. Results At 3 weeks following stent implantation, almost all struts analysed (~97%) had evidence of tissue coverage. The percentage of partially covered struts was comparable between both groups. However, the percentage of fully embedded struts was higher in the BMS group (81.22%, 49.75–95.52) compared with the MSG group (74.21%, 58.85–86.38). The stent-level analysis demonstrated reduction in neointimal formation (neointimal hyperplasia area and volume reduction of ~14% and ~19%, respectively) in the MSG versus the BMS group. In the strut-level analysis, an even greater reduction (~22% in neointimal thickness) was seen in the MSG group. Layered neointimal was present in ~6% of the OCT frames in the BMS group while it was not present in the MSG group. Conclusions MSG induced a more homogeneous and predictable pattern of surface healing in the early stages following stent implantation. The biological effect of MSG on stent healing has the potential to improve the safety profile of current generation drug-eluting stents. Classifications BMS, OCT, clinical trials. PMID:28674616
Vesga, Boris; Hernandez, Hector; Higuera, Sergio; Gasior, Pawel; Echeveri, Dario; Delgado, Juan A; Dager, Antonio; Arana, Camilo; Simonton, Charles; Maehara, Akiko; Palmaz, Julio; Granada, Juan F
2017-01-01
To evaluate the biological effect of microengineered stent grooves (MSG) on early strut healing in humans by performing optical coherence tomography (OCT) analysis 3 weeks following the implantation. In the experimental setting, MSG accelerate endothelial cell migration and reduce neointimal proliferation compared with bare metal stent (BMS). A total of 37 patients undergoing percutaneous coronary intervention with de novo coronary lesions were randomly assigned to either MSG (n=19) or an identical BMS controls (n=18). All patients underwent OCT imaging at 3 weeks. A total of 7959 struts were included in the final analysis. At 3 weeks following stent implantation, almost all struts analysed (~97%) had evidence of tissue coverage. The percentage of partially covered struts was comparable between both groups. However, the percentage of fully embedded struts was higher in the BMS group (81.22%, 49.75-95.52) compared with the MSG group (74.21%, 58.85-86.38). The stent-level analysis demonstrated reduction in neointimal formation (neointimal hyperplasia area and volume reduction of ~14% and ~19%, respectively) in the MSG versus the BMS group. In the strut-level analysis, an even greater reduction (~22% in neointimal thickness) was seen in the MSG group. Layered neointimal was present in ~6% of the OCT frames in the BMS group while it was not present in the MSG group. MSG induced a more homogeneous and predictable pattern of surface healing in the early stages following stent implantation. The biological effect of MSG on stent healing has the potential to improve the safety profile of current generation drug-eluting stents. BMS, OCT, clinical trials.
Fatigue and In Vivo Validation of a Peritoneum-Lined Self-Expanding Nitinol Stent-Graft
Bastijanic, Jennifer M.; Etscheidt, Jordan; Sattiraju, Mallika; Bonsignore, Craig; Kopchok, George; White, Rodney; Sarac, Timur P.
2014-01-01
Purpose To assess the fatigue and in vivo performance of a new stent-graft incorporating bovine peritoneum lining that is designed for application in peripheral vascular occlusive disease. Methods Bovine peritoneum-lined stent-grafts were subjected to accelerated in vitro pulsatile fatigue and axial/torsional fatigue testing designed to simulate 10 years of physiological strain on the devices. At specified times the devices were evaluated for stent fracture, suture failure, or tissue tearing. Seven dogs underwent bilateral common iliac artery (CIA) balloon angioplasty injury with unilateral placement of the peritoneum-lined stent-graft. Angiography and intravascular ultrasound were performed prior to treatment, after treatment, and prior to sacrifice at 30 days. Vessels were perfusion fixed and histologically evaluated at 5 regions: above stent, proximal stent, mid stent, distal stent, and below stent. Results No evidence of stent, suture, or tissue failure was present during or after pulsatile and axial/torsional fatigue testing. At 30±0.3 days after implantation, all vessels were patent. The average lumen area at explantation across stented vessels was 25.45 mm2. Lumen areas tended to be reduced above (23.57 mm2) and below (24.17 mm2) the stent. Lumen areas were consistent across stented regions at explantation (proximal stent 27.80 mm2, mid stent 25.88 mm2, and distal stent 25.81 mm2). The mean neointimal area in peritoneum-lined stents was 2.02±1.52 mm2, with a neointima:media ratio of 1.03±0.50. These values were significantly lower in the above and below stent areas than in the stented regions, but there was no difference in either measure within the proximal, mid, or distal stent. Conclusion The custom-designed peritoneum-lined stent-graft is promising for clinical peripheral applications due to its ability to resist relevant long-term physiological stresses and outstanding short-term patency rates in canine implantations. PMID:25290804
Spinetta, Roberta; Cannizzo, Paola Maria Loredana; Consolandi, Giulia; Lavia, Carlo; Germinetti, Francesco; Rolle, Teresa
2017-01-01
Objective To evaluate the efficacy and safety of the Xen Gel Stent and provide a macro- and microscopic analyses of bleb morphology. Methods A prospective 12-month study on patients with primary open-angle glaucoma. Patients underwent implantation of the XEN Gel Stent (Allergan INC, Dublin, Ireland) either alone or combined with a cataract surgery. Biomicroscopy, in vivo confocal microscopy (IVCM), and anterior segment-optical coherence tomography (AS-OCT) were used to assess bleb morphology. Safety parameters were adverse events, best corrected visual acuity, visual field, and corneal endothelial cell loss. A postoperative IOP ≤ 18 mmHg without or on medications was respectively defined as complete and qualified success while an IOP ≥ 18 mmHg was defined as failure. Results Twelve eyes of 11 patients were evaluated. At one year, 5 out of 10 patients available achieved a complete success while five were qualified success. AS-OCT showed that bleb wall reflectivity was significantly higher in the failure group; IVCM revealed that stromal density was significantly lower in the success group. No safety issues were recorded. Conclusion Implantation of the XEN Gel Stent appears to be a safe and effective procedure. AS-OCT and IVCM may be helpful in bleb assessment. PMID:28751986
McElhinney, Doff B; Cheatham, John P; Jones, Thomas K; Lock, James E; Vincent, Julie A; Zahn, Evan M; Hellenbrand, William E
2011-12-01
Among patients undergoing transcatheter pulmonary valve (TPV) replacement with the Melody valve, risk factors for Melody stent fracture (MSF) and right ventricular outflow tract (RVOT) reintervention have not been well defined. From January 2007 to January 2010, 150 patients (median age, 19 years) underwent TPV implantation in the Melody valve Investigational Device Exemption trial. Existing conduit stents from a prior catheterization were present in 37 patients (25%, fractured in 12); 1 or more new prestents were placed at the TPV implant catheterization in 51 patients. During follow-up (median, 30 months), MSF was diagnosed in 39 patients. Freedom from a diagnosis of MSF was 77±4% at 14 months (after the 1-year evaluation window) and 60±9% at 39 months (3-year window). On multivariable analysis, implant within an existing stent, new prestent, or bioprosthetic valve (combined variable) was associated with longer freedom from MSF (P<0.001), whereas TPV compression (P=0.01) and apposition to the anterior chest wall (P=0.02) were associated with shorter freedom from MSF. Freedom from RVOT reintervention was 86±4% at 27 months. Among patients with a MSF, freedom from RVOT reintervention after MSF diagnosis was 49±10% at 2 years. Factors associated with reintervention were similar to those for MSF. MSF was common after TPV implant in this multicenter experience and was more likely in patients with severely obstructed RVOT conduits and when the TPV was directly behind the anterior chest wall and/or clearly compressed. A TPV implant site protected by a prestent or bioprosthetic valve was associated with lower risk of MSF and reintervention.
Forrest, John K; Lansky, Alexandra J; Meller, Stephanie M; Hou, Liming; Sood, Poornima; Applegate, Robert J; Wang, John C; Skelding, Kimberly A; Shah, Aakar; Kereiakes, Dean J; Sudhir, Krishnankutty; Cristea, Ecaterina; Yaqub, Manejeh; Stone, Gregg W
2013-06-01
The aim of this study was to determine whether patients from the Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System in the Treatment of Patients With de Novo Native Coronary Artery Lesions (SPIRIT) IV trial who underwent percutaneous coronary intervention, who had target lesions with jailed side branches, had improved clinical outcomes when treated with the XIENCE V versus Taxus Express(2) drug-eluting stent. In the SPIRIT III randomized trial, patients with target lesions with jailed side branches after XIENCE V compared with Taxus Express(2) implantation had lower 2-year rates of major adverse cardiac events. The SPIRIT IV trial represents a larger more diverse patient population compared with SPIRIT III. In the large-scale, prospective, multicenter, randomized SPIRIT IV trial, 3,687 patients who underwent coronary stenting with up to 3 de novo native coronary artery lesions were randomized 2:1 to receive XIENCE V versus Taxus Express(2) stents. Two-year clinical outcomes of patients with or without jailed side branches after stenting were compared. A jailed side branch was defined as any side branch >1.0 mm in diameter within the target segment being stented, excluding bifurcations deemed to require treatment. Of the 3,687 patients in SPIRIT IV, a total of 1,426 had side branches that were jailed during angioplasty of the target lesion. Patients with jailed side branches after XIENCE V compared with Taxus Express(2) implantation had significantly lower 2-year rates of target lesion failure (6.5% vs 11.9%, p = 0.001), major adverse cardiac events (6.6% vs 12.2%, p = 0.0008), ischemia-driven target vessel revascularization (4.1% vs 7.9%, p = 0.004), and stent thrombosis (0.6% vs 2.8%, p = 0.001). In conclusion, patients with jailed side branches after stenting with XIENCE V compared to Taxus Express(2) devices had superior clinical outcomes at 2 years in the large-scale randomized SPIRIT IV trial. Copyright © 2013 Elsevier Inc. All rights reserved.
Fea, Antonio M; Belda, Jose I; Rękas, Marek; Jünemann, Anselm; Chang, Lydia; Pablo, Luis; Voskanyan, Lilit; Katz, L Jay
2014-01-01
Purpose The purpose of this study was to compare outcomes of subjects with open-angle glaucoma (OAG) not controlled on one medication who underwent either implantation of two iStent inject® trabecular micro-bypass devices or received medical therapy consisting of a fixed combination of latanoprost/timolol. Patients and methods Of 192 subjects who qualified for the study and were enrolled, 94 were randomized to surgery with implantation of two iStent inject® devices in the treated eye and 98 to receive medical therapy. Results At the month 12 visit, 94.7% of eyes (89/94) in the stent group reported an unmedicated intraocular pressure (IOP) reduction of ≥20% versus baseline unmedicated IOP, and 91.8% of eyes (88/98) in the medical therapy group reported an IOP reduction ≥20% versus baseline unmedicated IOP. A 17.5% between-group treatment difference in favor of the iStent inject group was statistically significant (P=0.02) at the ≥50% level of IOP reduction. An IOP ≤18 mmHg was reported in 92.6% of eyes (87/94) in the iStent inject group and 89.8% of eyes (88/98) in the medical therapy group. Mean (standard deviation) IOP decreases from screening of 8.1 (2.6) mmHg and 7.3 (2.2) mmHg were reported in the iStent inject and medical therapy groups, respectively. A high safety profile was also noted in this study in both the iStent inject and medical therapy groups, as measured by stable best corrected visual acuity, cup-to-disc ratio, and adverse events. Conclusion These data show that the use of iStent inject is at least as effective as two medications, with the clinical benefit of reducing medication burden and assuring continuous treatment with full compliance to implant therapy as well as having a highly favorable safety profile. PMID:24855336
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mermuys, Koen; Maleux, Geert, E-mail: geert.maleux@uzleuven.be; Heye, Sam
2008-07-15
Four children, three boys and one girl, with a median age of 9 years 8 months, underwent transjugular intrahepatic portosystemic shunt creation with an expanded polytetrafluoroethylene (e-PTFE)-covered nitinol stent. The stent-graft was successfully placed in all four patients without any complication. Clinical and biochemical improvement was noted in all four patients during follow-up. Radiological follow-up with use of duplex ultrasound showed a recurrent stenosis of the shunt 180 days after stent-graft implantation in one patient. This was treated with placement of an additional stent-graft, re-expanding completely the recurrent stenosis. In the other three patients, the stent-graft remained fully patent untilmore » the end of the study or until orthotopic liver transplantation. These preliminary results suggest that use of the Viatorr ePTFE-covered stent-graft in children is safe and feasible, with potentially the same high patency rate and improved clinical outcome as reported in adult patients.« less
Lee, Michael S; Nguyen, Heajung; Shlofmitz, Richard
2017-02-01
We analyzed the incidence of bradycardia and the safety of patients with severely calcified coronary lesions who underwent orbital atherectomy without the insertion of a temporary pacemaker. The presence of severely calcified coronary lesions can increase the complexity of percutaneous coronary intervention due to the difficulty in advancing and optimally expanding the stent. High-pressure inflations to predilate calcified lesions may cause angiographic complications like perforation and dissection. Suboptimal stent expansion is associated with stent thrombosis and restenosis. Orbital atherectomy safely and effectively modifies calcified plaque to facilitate optimal stent expansion. The incidence of bradycardia in orbital atherectomy is unknown. Fifty consecutive patients underwent orbital atherectomy from February 2014 to September 2016 at our institution, none of whom underwent insertion of a temporary pacemaker. The final analysis included 47 patients in this retrospective study as 3 patients were excluded because of permanent pacemaker implantation. The primary endpoint was significant bradycardia, defined as bradycardia requiring emergent pacemaker placement or a heart rate <50 bpm at the end of atherectomy. The primary endpoint occurred in 4% of all patients, all driven by patients who experienced a heart rate decreasing to <50 bpm. The major adverse cardiac and cerebral event rate was 6%, driven by death (2%) and myocardial infarction (4%). No patient experienced target-vessel revascularization, stroke, or stent thrombosis. Angiographic complications included perforation in 2%, slow-flow in 4%, and flow-limiting dissection in 0%. Significant bradycardia was uncommon during orbital atherectomy. Performing orbital atherectomy without a temporary pacemaker appears to be safe.
High-Resolution CT and Angiographic Evaluation of NexStent Wall Adaptation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nemes, Balazs, E-mail: nembal@freemail.hu; Lukacs, Levente; Balazs, Gyoergy
2009-05-15
Carotid stenting is a minimally invasive treatment for extracranial carotid artery stenosis. Stent design may affect technical success and complications in a certain subgroup of patients. We examined the wall adaptability of a new closed-cell carotid stent (NexStent), which has a unique rolled sheet design. Forty-one patients had 42 carotid arteries treated with angioplasty and stenting for internal carotid artery stenosis. The mean patient age was 65 {+-} 10 years. All patients underwent high-resolution computed tomographic angiography after the stent implantation. Data analysis included pre- and postprocedural stenosis, procedure complications, plaque calcification, and stent apposition. We reviewed the angiographic andmore » computed tomographic images for plaque coverage and stent expansion. All procedures were technically successful. Mean stenosis was reduced from 84 {+-} 8% before the procedure to 15.7 {+-} 7% after stenting. Two patients experienced transient ischemic attack; one patient had bradycardia and hypotension. Stent induced kinking was observed in one case. Good plaque coverage and proper overlapping of the rolled sheet was achieved in all cases. There was weak correlation between the residual stenosis and the amount of calcification. The stent provides adequate expansion and adaptation to the tapering anatomy of the bifurcation.« less
Clinical outcomes and stent thrombosis following off-label use of drug-eluting stents.
Win, Htut K; Caldera, Angel E; Maresh, Kelly; Lopez, John; Rihal, Charanjit S; Parikh, Manish A; Granada, Juan F; Marulkar, Sachin; Nassif, Deborah; Cohen, David J; Kleiman, Neal S
2007-05-09
Clinical trials that have excluded patients at high risk for cardiac events have led to commercial labeling approval of drug-eluting stents; nevertheless, such high-risk patients commonly undergo stent placement in clinical practice. The degree to which they experience cardiac events at a higher rate than non-high-risk patients is unclear. To assess the rates of major adverse cardiac events during the index admission and 1 year after the implantation of drug-eluting stents in patients with high-risk angiographic and clinical features. From July 2004 to September 2005, consecutive patients who underwent attempted stent placement at 42 different hospitals throughout the United States were enrolled in a prospective multicenter registry. We analyzed outcomes of 3323 patients who received at least 1 drug-eluting stent for a reason other than acute ST-segment elevation myocardial infarction. The study population was divided into 2 groups based on presence of at least 1 of 9 off-label characteristics based on the current US Food and Drug Administration-approved indications for sirolimus- and paclitaxel-eluting stents. The composite clinical outcomes of death, myocardial infarction, or target vessel revascularization during the index admission and death, myocardial infarction, or target lesion revascularization at 1 year were evaluated. Of the 3323 patients, 1817 (54.7%) had at least 1 off-label characteristic. During the index hospitalization, the composite clinical outcome occurred in 198 (10.9%) of patients in the off-label group and 76 (5.0%) of patients in the on-label group (adjusted odds ratio, 2.32; 95% confidence interval [CI], 1.75-3.07; P<.001). At 1 year, the composite clinical outcome occurred more often in the off-label group compared with the on-label group; 309 (17.5%) vs 131 (8.9%) (adjusted hazard ratio [HR], 2.16; 95% CI, 1.74-2.67; P<.001). Stent thrombosis also occurred more frequently among patients in the off-label group during the initial hospitalization (8 [0.4%] vs 0) and at 1 year: 29 (1.6%) vs 13 (0.9%), adjusted HR, 2.29 (95% CI, 1.02-5.16; P = .05). Compared with on-label use, off-label use of drug-eluting stents is associated with a higher rate of adverse outcomes during the index admission and at 1 year. Stent thrombosis occurred predominantly in patients who underwent off-label drug-eluting stent implantation. Clinicians should be cautious about extrapolating the benefits of drug-eluting stents over bare-metal stents observed in randomized clinical trials to higher-risk clinical settings that have not been assessed.
Optimal treatment of coronary-to-pulmonary artery fistula: surgery, coil or stent graft?
Lipiec, Piotr; Peruga, Jan Zbigniew; Jaszewski, Ryszard; Pawłowski, Witold; Kasprzak, Jarosław
2013-01-01
We report a case of a 57-year-old man with typical angina due to a coronary artery-to-pulmonary artery fistula, which was evident on transthoracic and transesophageal echocardiography with color Doppler flow mapping. The diagnosis was confirmed by coronary angiography. The patient underwent surgical ligation of the fistula. However, repeated transesophageal echocardiography and coronary angiography revealed persistence of the fistula with significant left-to-right shunt. The orifice of the fistula was then obliterated by stent-graft implantation, which was proven successful by angiography and echocardiography. PMID:24570733
Goreczny, Sebastian; Qureshi, Shakeel A; Rosenthal, Eric; Krasemann, Thomas; Nassar, Mohamed S; Anderson, David R; Morgan, Gareth J
2017-07-01
We aimed to compare the procedural and mid-term performance of a specifically designed self-expanding stent with balloon-expandable stents in patients undergoing hybrid palliation for hypoplastic left heart syndrome and its variants. The lack of specifically designed stents has led to off-label use of coronary, biliary, or peripheral stents in the neonatal ductus arteriosus. Recently, a self-expanding stent, specifically designed for use in hypoplastic left heart syndrome, has become available. We carried out a retrospective cohort comparison of 69 neonates who underwent hybrid ductal stenting with balloon-expandable and self-expanding stents from December, 2005 to July, 2014. In total, 43 balloon-expandable stents were implanted in 41 neonates and more recently 47 self-expanding stents in 28 neonates. In the balloon-expandable stents group, stent-related complications occurred in nine patients (22%), compared with one patient in the self-expanding stent group (4%). During follow-up, percutaneous re-intervention related to the ductal stent was performed in five patients (17%) in the balloon-expandable stent group and seven patients (28%) in self-expanding stents group. Hybrid ductal stenting with self-expanding stents produced favourable results when compared with the results obtained with balloon-expandable stents. Immediate additional interventions and follow-up re-interventions were similar in both groups with complications more common in those with balloon-expandable stents.
Kundi, Harun; Korkmaz, Ahmet; Balun, Ahmet; Cicekcioglu, Hulya; Kiziltunc, Emrullah; Gursel, Koray; Cetin, Mustafa; Ornek, Ender; Ileri, Mehmet
2017-10-01
We examined the impact of the preprocedural triglyceride (TG)/high-density lipoprotein cholesterol (HDL-C) ratio on risk of in-stent restenosis (ISR). Patients with typical anginal symptoms and/or positive treadmill or myocardial perfusion scintigraphy test results who underwent successful coronary stent implantation due to stable angina were examined; 1341 patients were enrolled. The hospital files of the patients were used to gather data. Cox regression analysis showed that the TG/HDL-C ratio was independently associated with the presence of ISR ( P < .001). Moreover, diabetes mellitus ( P = .007), smaller stent diameter ( P = .046), and smoking status ( P = .001) were also independently associated with the presence of ISR. Using a cutoff of 3.8, the TG/HDL-C ratio predicted the presence of ISR with a sensitivity of 71% and a specificity of 68%. Also, the highest quartile of TG/HDL-C ratio had the highest rate of ISR ( P < .001). Measuring preprocedural TG/HDL-C ratio, in fasting or nonfasting samples, could be beneficial for the risk assessment of ISR. However, further large-scale prospective studies are required to establish the exact role of this simple, easily calculated, and reproducible parameter in the pathogenesis of ISR.
Otsuka, Yoritaka; Ishiwata, Sugao; Inada, Tsukasa; Kanno, Hiroyuki; Kyo, Eisho; Hayashi, Yasuhiko; Fujita, Hiroshi; Michishita, Ichiro
2011-04-01
Long-term outcomes after sirolimus-eluting stent (SES) implantation in haemodialysis (HD) patients have remained controversial. We investigated the impact of HD on outcomes after SES implantation. We analysed the data on 2050 patients who underwent SES implantation in a multi-centre prospective registry in Japan. Three-year clinical outcomes were compared between the HD group (n = 106) and the non-haemodialysis (NH) group (n = 1944). At the 3-year clinical follow-up, the rates of unadjusted cardiac mortality (HD: 16.3 vs. NH: 2.3%) and target-lesion revascularization (TLR) (HD: 19.4 vs. NH: 6.6%) were significantly higher in the HD group than the NH group (P < 0.001). Although HD group had a numerically higher stent thrombosis rate, the difference in stent thrombosis between the two groups (HD: 2.0 vs. NH: 0.7%) did not reach statistical significance. Using Cox's proportional-hazard models with propensity score adjustment for baseline differences, the HD group had higher risks of TLR [HD: 16.3 vs. NH: 6.1%; hazard ratio, 2.83; 95% confidence interval (CI): 1.62-4.93, P = 0.0003] and cardiac death (HD: 12.3 vs. NH: 2.3%; hazard ratio, 5.51; 95% CI: 2.58-11.78, P < 0.0001). The consistent results of analyses, whether unadjusted or adjusted for other baseline clinical and procedural differences, identify HD as an independent risk factor for cardiac death and TLR. Percutaneous coronary intervention with SES in HD patients has a higher incidence of repeat revascularization and mortality compared with those in NH patients. Haemodialysis appears to be strongly associated with mortality and repeat revascularization even after SES implantation.
Goldberg, Jason F; Jensen, Craig L; Krishnamurthy, Rajesh; Varghese, Nidhy P; Justino, Henri
2018-01-01
We describe the long-term follow-up of a child with recurrent hemoptysis due to severe pulmonary vein stenosis decompressing via collaterals to esophageal varices. Case report SETTING: Tertiary children's hospital PATIENT: Single child through ages 2- to 11-year old INTERVENTIONS: The child underwent cutting balloon angioplasty, bare metal stenting, and implantation of a PTFE-covered stent, all of which failed rapidly. Only after placement of a paclitaxel drug eluting stent did he have prolonged relief from hemoptysis and long-term patency of the treated vein. The stents were serially dilated to keep up with somatic growth of the child, eventually culminating in the need to induce intentional stent fracture. We highlight novel transcatheter techniques to treat this vexing condition, discuss mechanisms of disease treatment and progression, and present the only patient with this rare combination of lesions to have achieved both longstanding pulmonary vein patency and resolution of esophageal varices. © 2017 Wiley Periodicals, Inc.
Schneider, Peter A; Giasolli, Robert; Ebner, Adrian; Virmani, Renu; Granada, Juan F
2015-02-01
This study provides preliminary data on the safety and feasibility of the use of a novel focal implant for managing post-percutaneous transluminal balloon angioplasty (post-PTA) dissection. Post-PTA dissection of the lower extremity arteries is managed with stent placement. This provides an acceptable post-intervention result but has long-term disadvantages, such as in-stent restenosis. Focal treatment of post-PTA dissection and avoidance of stents are the objectives of the Tack-It (Intact Vascular, Inc., Wayne, Pennsylvania) device. A preclinical study and first-in-human data are presented. Seven swine underwent superficial femoral artery device placement, with a self-expanding nitinol stent on 1 side and a series of 4 Tack-It devices on the other side. Specimens were harvested at 28 days. The clinical study included 15 limbs that underwent revascularization for critical limb ischemia (n = 9) or claudication (n = 6). Twenty-five lesions were treated in the superficial femoral (n = 8), popliteal (n = 7), and tibial (n = 10) arteries. The preclinical study demonstrated a reduction in stenosis with the Tack-It (16.8 ± 2.6%) compared with stents (46.4 ± 9.8%). Neointimal thickness and injury score decreased with the Tack-It. Clinically, Tack-It placement resulted in acute technical success with resolution of the post-PTA dissection in 100% of lesions. There were no device-related complications or major amputations. Eighteen of the 25 lesions were available for angiographic follow-up at 1-year, and patency was 83.3%. Preclinical data suggest that the Tack-It device causes minimal vessel injury. Clinical use of the Tack-It to manage post-PTA dissection was safe and feasible in this early study and resulted in apposition of dissection flaps without stent placement. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Very late stent thrombosis in a bare-metal stent, 9 years after implantation.
Almasswary, Adel A
2009-06-01
Very late bare-metal stent thrombosis occurring beyond one year after stenting is uncommon. We report a case of bare-metal stent thrombosis presenting as acute myocardial infarction. The patient's stent was implanted 9 years ago, however, he was not adherent to his antiplatelet therapy (aspirin). This case highlights the importance of antiplatelet therapy in patients with stents even many years after implantation.
Di Martino, Luigi F M; Soliman, Osama I I; van Gils, Lennart; Vletter, Wim B; Van Mieghem, Nicolas M; Ren, Ben; Galema, Tjebbe W; Schultz, Carl; de Jaegere, Peter P T; Di Biase, Matteo; Geleijnse, Marcel L
2017-06-01
Paravalvular aortic leakage (PVL) after transcatheter aortic valve implantation (TAVI) is a complication with potentially severe consequences. The relation between native aortic root calcium burden, stent frame eccentricity and PVL was not studied before. Two-hundred-and-twenty-three consecutive patients with severe aortic stenosis who underwent TAVI with a Medtronic CoreValve System© and who had available pre-discharge transthoracic echocardiography were studied. Echocardiographic stent inflow frame eccentricity was defined as major-minor diameter in a short-axis view >2 mm. PVL was scored according to the updated Valve Academic Research Consortium (VARC-2) recommendations. In a subgroup of 162 (73%) patients, the calcium Agatston score was available. Stent frame eccentricity was seen in 77 (35%) of patients. The correlation between the Agatston score and stent frame eccentricity was significant (ρ = 0.241, P = 0.003). Paravalvular leakage was absent in 91 cases (41%), mild in 67 (30%), moderate in 51 (23%), and severe in 14 (6%) cases. The correlation between stent frame eccentricity and PVL severity was significant (ρ = 0.525, P < 0.0001). There was a relation between particular eccentric stent frame shapes and the site of PVL. Calcification of the aortic annulus is associated with a subsequent eccentric shape of the CoreValve prosthesis. This eccentric shape results in more PVL, with the localization of PVL related to the shape of stent frame eccentricity. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.
Long-term follow-up of stentless prosthesis.
Sansone, Fabrizio; Dato, Guglielmo Mario Actis; Zingarelli, Edoardo; Ferrero, Emanuele; Prot, Sara; Ceresa, Fabrizio; Patanè, Francesco; Casabona, Riccardo
2014-05-01
Stentless prostheses have an interesting hemodynamic performance when compared to stented prostheses and are recommended in cases of small aortic annulus. From January 1996 to January 2004, 138 patients suffering from aortic disease, underwent aortic valve replacement. • Group A: 93 patients underwent stentless aortic valve implantation [stentless Biocor (Biocor Industria e Pesguisa Ltda, Belo Horizonte, Brazil) and stentless Sorin (Sorin Group, Saluggia, Italy)]. • Group B: 45 patients underwent stented aortic valve implantation (stented Biocor). Patients were assessed by clinical evaluation and echocardiography after a mean follow up of 124.5 ± 58.2 months. There was a significant difference in terms of time of extracorporeal circulation and aortic cross clamp. The actuarial survival at 4, 8, 12, and 15 years is 77%, 50%, 21%, and 18%, respectively. Freedom from reoperation at 4, 8, 12, and 14 years was 92%, 83%, 73%, and 63%, respectively. Freedom from all events, death, and reoperation at 4, 8, 12, and 14 years was 70%, 39%, 13%, and 8%, respectively. There is no statistical difference among the two groups in terms of actuarial survival, freedom from reoperation, and freedom from re-hospitalization for prosthesis-related causes. There was a significantly higher incidence of pacemaker implantation in Group A and the causes are not known. The rate of freedom from reoperation is high in both groups for the patients who remained alive. There was no statistical difference about prosthesis dysfunction between the two groups. The higher incidence of death in Group A cannot be explained by causes related to the prosthesis because there is no difference in terms of causes of death. Rates of reoperation did not differ between the two groups. The results obtained with stentless prostheses are encouraging even in long-term follow-up. Copyright © 2013 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.
Zang, Chuanshan; Sun, Jian; Sun, Yan
2016-03-01
We report the treatment of one patient with pharynx anastomotic stenosis after cervical esophagealresection by stent implantation. The patient suffered from serious pharynx anastomotic stenosis after gastric-pha-ryngeal anastomosis. After balloon-dilatation,a domestic self-expanding Z-stents was implanted in the stricture ofthe esophagus under the X-rays. After stent implantation, the patient has been leading a normal life for threeyears. Balloon dilatation and stent implantation is an effective and safe method in the treatment of patients withpharynx anastomotic stenosis.
Pockett, C R; Moore, J W; El-Said, H G
2017-02-01
Adverse events from Melody valve implantation may be catastrophic. To date a role for three dimensional rotational angiography of the aortic root (3DRAA) during Melody valve implantation has not been established. To describe the role of 3DRAA in the assessment of Melody valve candidacy and to demonstrate that it may improve outcomes. All patients who underwent cardiac catheterisation for Melody valve implantation and 3DRAA between August 2013 and February 2015 were reviewed. 31 patients had 3DRAA with balloon sizing. Ten were deemed not Melody candidates (5 coronary compression, 2 aortic root distortion with cusp flattening, 2 RVOT was too large, and 1 had complex branch stenosis and a short landing zone). Of the 21 patients who were Melody candidates, 12 had conduits, 6 prosthetic valves and 3 native RVOTs. In patients with conduits, the technique of stenting the conduit prior to dilation was used after measuring the distance between the conduit and the coronary arteries on 3DRAA. In the Melody patients, we had 100% procedural success and no serious adverse events (coronary compression, tears, stent fracture or endocarditis). As a tool for case selection, 3DRAA may facilitate higher procedural success and decreased risk of serious adverse events. Furthermore, 3D rotational angiography allows stenting of the conduit prior to dilation, which may prevent tears and possibly endocarditis.
NASA Astrophysics Data System (ADS)
Hussain, Shadman; Bulusu, Kartik V.; Plesniak, Michael W.
2013-11-01
A common treatment for atherosclerosis is the opening of narrowed arteries resulting from obstructive lesions by angioplasty and stent implantation to restore unrestricted blood flow. ``Type-IV'' stent fractures involve complete transverse, linear fracture of stent struts, along with displacement of the stent fragments. Experimental data pertaining to secondary flows in the presence of stents that underwent ``Type-IV'' fractures in a bent artery model under physiological inflow conditions were obtained through a two-component, two-dimensional (2C-2D) PIV technique. Concomitant stent-induced flow perturbations result in secondary flow structures with complex, multi-scale morphologies and varying size-strength characteristics. Ultimately, these flow structures may have a role to play in restenosis and progression of atherosclerotic plaque. Vortex circulation thresholds were established with the goal of resolving and tracking iso-circulation secondary flow vortical structures and their morphological changes. This allowed for a parametric evaluation and quantitative representation of secondary flow structures undergoing deformation and spatial reorganization. Supported by NSF Grant No. CBET- 0828903 and GW Center for Biomimetics and Bioinspired Engineering.
Villa, Adolfo; Arnold, Roman; Sánchez, Pedro L; Gimeno, Federico; Ramos, Benigno; Cantero, Teresa; Fernández, Maria Eugenia; Sanz, Ricardo; Gutiérrez, Oliver; Mota, Pedro; García-Frade, Javier; San Román, José Alberto; Fernández-Avilés, Francisco
2009-06-15
The aims of this study were to assess the safety of drug-eluting stent (DES) use and to compare the incidence of in-stent restenosis (ISR) and neointimal hyperplasia formation according to the type of stent implanted (DES vs bare-metal stents [BMS]) in patients who underwent intracoronary bone marrow mononuclear cell transplantation after acute ST elevation myocardial infarction. Fifty-nine patients with successfully revascularized ST elevation myocardial infarction (37 using BMS and 22 using DES) underwent paired angiographic examinations at baseline and 6 to 9 months after the intracoronary injection of 91 million +/- 56 million autologous bone marrow mononuclear cells. A subgroup of 30 patients also underwent serial intravascular ultrasound examinations. Off-line angiographic assessment showed 4 cases of binary ISR, primarily in BMS (3 cases), and no major adverse cardiac events were associated with stent type (mean follow-up period 41 +/- 10 months). At follow-up, angiographic late luminal loss was significantly lower in patients with DES than in those patients with BMS (0.35 +/- 0.66 vs 0.71 +/- 0.38 mm, p = 0.011). Multivariate analysis identified the use of DES (beta = -0.32, 95% confidence interval [CI] -0.57 to -0.26, p = 0.03) and a smaller baseline reference vessel diameter (beta = 0.29, 95% CI 0.04 to 0.54, p = 0.02) as independent predictors of lower late loss. Moreover, intravascular ultrasound showed a significant reduction of in-stent neointimal hyperplasia formation related to DES use compared with BMS use (Delta neointimal hyperplasia volume 5.4 mm(3) [95% CI 2.7 to 28.1] vs 35.9 mm(3) [95% CI 22.0 to 43.6], p = 0.035). In conclusion, these findings suggest that the use of DES is safe and may prevent ISR and neointimal hyperplasia formation in patients who undergo intracoronary bone marrow mononuclear cell transplantation after a successfully revascularized ST elevation myocardial infarction.
Sigler, Matthias; Klötzer, Julia; Quentin, Thomas; Paul, Thomas; Möller, Oliver
2015-12-01
Stent implantation into the tracheo-bronchial system may be life-saving in selected pediatric patients with otherwise intractable stenosis of the upper airways. Following implantation, significant tissue proliferation may occur, requiring re-interventions. We sought to evaluate the effect of immunosuppressive coating of the stents on the extent of tissue proliferation in an animal model. Bare metal and sirolimus-coated stents (Bx Sonic and Cypher Select, Johnson & Johnson, Cordis) were implanted into non-stenotic lower airways of New Zealand white rabbits (weight 3.1 to 4.8 kg). Three stents with sirolimus coating and six bare metal stents could be analyzed by means of histology and immunohistochemistry 12 months after implantation. On a macroscopic evaluation, all stents were partially covered with a considerable amount of whitish tissue. Histologically, these proliferations contained fiber-rich connective tissue and some fibromuscular cells without significant differences between both stent types. The superficial tissue layer was formed by typical respiratory epithelium and polygonal cells. Abundant lymphocyte infiltrations and moderate granulocyte infiltrations were found in both groups correspondingly, whereas foreign-body reaction was more pronounced around sirolimus-eluting stents. After stent implantation in the tracheo-bronchial system of rabbits, we found tissue reactions comparable to those seen after stent implantation into the vascular system. There was no difference between coated and uncoated stents with regard to quality and quantity of tissue proliferation. We found, however, a significantly different inflammatory reaction with a more pronounced foreign-body reaction in sirolimus-coated stents. In our small series, drug-eluting stents did not exhibit any benefit over bare metal stents in an experimental setting.
Yu, Yi; Zhou, Yujie; Ma, Qian; Jia, Shuo; Wu, Sijing; Sun, Yan; Liu, Xiaoli; Zhao, Yingxin; Liu, Yuyang; Shi, Dongmei
2017-01-15
This study sought to explore the efficacy of the conical stent implantation in the coronary artery by comparing the effects of cylindrical and conical stents on wall shear stress (WSS) and velocity of flow and fractional flow reserve (FFR). The traditional cylindrical stent currently used in the percutaneous coronary intervention (PCI) has a consistent diameter, which does not match the physiological change of the coronary artery. On the contrary, as a new patent, the conical stent with tapering lumen is consistent with the physiological change of vascular diameter. However, the effect of the conical stent implantation on the coronary hemodynamics remains unclear. The coronary artery, artery stenosis and two stent models were established by Solidworks software. All models were imported into the computational fluid dynamics (CFD) software ANSYS ICEM-CFD to establish the fluid model. After the boundary conditions were set, CFD analysis was proceeded to compare the effects of two stent implantation on the change of WSS, velocity of flow and FFR. Hemodynamic indexes including FFR, blood flow velocity distribution (BVD) and WSS were improved by either the cylindrical or the conical stent implantation. However, after the conical stent implantation, the change of FFR seemed to be slower and more homogenous; the blood flow velocity was more appropriate without any obvious blood stagnation and direction changes; the WSS after the conical stent implantation was uniform from the proximal to distal side of the stent. Compared with the cylindrical stent, the conical stent implantation in the coronary artery can make the changes of vascular hemodynamic more closer to the physiological condition, which can reduce the incidence of intra-stent restenosis and thrombosis, thus making it more suitable for PCI therapy. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
External heating of stents by radio waves Pilot studies in rabbit aorta
DOE Office of Scientific and Technical Information (OSTI.GOV)
Levitt, Adam B.; Robinson, Keith; Chronos, Nicolas A.F.
Purpose: This experiment was designed to assess the feasibility of radio frequency energy delivered by a prototype radio frequency generator inductive heating device (REVAX) positioned external to the body, for transient heating of stents after arterial implant. Methods and Materials: Twenty-one New Zealand White rabbits underwent stenting of their infrarenal aorta. Nine rabbits were stented and immediately placed in the REVAX for external stent heating with internal temperature probes in place. Twelve rabbits were stented and 3 days later either heated or placed in the generator as a sham for 20 min. The animals were terminated 28 days later. Results:more » The REVAX was able to heat the aortic stents in a controlled fashion; in Phase II experiments, the stent temperature was raised to 42 deg. C for 20 min. In Phase I mild necrosis was noted at the stent struts. In Phase II, necrosis and mineralization of the media was seen at the stent struts, and evidence of neointimal suppression was observed. Conclusion: This study demonstrated that external heating of stents in a blood vessel in a live animal via radio frequency energy is feasible. Further studies will be needed to assess whether any specific heating regimen might inhibit fibrocellular neointimal hyperplasia.« less
Liatsikos, Evangelos N; Kagadis, George C; Karnabatidis, Dimitrios; Katsanos, Konstantinos; Papathanassiou, Zafiria; Constantinides, Constantinos; Perimenis, Petros; Nikiforidis, George C; Stolzenburg, Jens-Uwe; Siablis, Dimitrios
2007-07-01
We report our long-term experience with the management of benign ureteroileal anastomotic strictures using self-expandable metal stents. A total of 16 male and 2 female patients with a mean+/-SD age of 72+/-7 years (range 66 to 78) with benign fibrotic strictures at the site of ureteroileal anastomosis underwent implantation of self-expandable metal stents with a nominal diameter of 6 to 8 mm. A total of 24 ureteroileal conduits were treated. The external nephrostomy tubes were removed after fluoroscopic validation of ureteral patency. Patients were followed with blood biochemistry, ultrasonography, urography and/or virtual endoscopy. Retrograde external-internal catheter insertion through the cutaneous stoma was performed in cases of recalcitrant stricture. The technical success rate of ureteroileal stricture crossing and stenting was 100% (24 of 24 cases). Mean followup was 21 months (range 7 to 50). The clinical success rate during the immediate post-stenting period was 70.8% (17 of 24 cases). The 1 and 4-year primary patency rates were 37.8% and 22.7%, respectively. Secondary interventions included repeat balloon dilation in 15 ureters, of which 8 also underwent subsequent coaxial stent placement. The 1 and 4-year secondary patency rates were 64.8% and 56.7%, respectively. Except in 2 patients who died external-internal Double-J catheters continued to be inserted retrograde in 6 ureteroileal conduits. They are periodically exchanged to prevent mucous inspissation and stent encrustation. Metal stents served as the definitive treatment for stricture in more than half of the cases, whereas in the remainder the stents allowed the uncomplicated and regular exchange of Double-J catheters in retrograde fashion. This combined, less invasive treatment for ureteroileal anastomotic strictures may help patients avoid surgical revision and preserve quality of life.
Rubartelli, Paolo; Terzi, Giacomo; Borgo, Lorenzo; Giachero, Corinna
2002-03-01
A patient with unstable angina was treated with elective Palmaz-Schatz stent implantation on a focal stenosis of the left circumflex artery. One year later, a large (13 mm in diameter) coronary artery aneurysm was diagnosed at angiography in the stented site. Intravascular ultrasound examination confirmed the presence of a true aneurysm located at the proximal end of the stent. The aneurysm was successfully treated with a Jostent Graft (Jomed Implantate) consisting of two slotted tube stainless steel stents supporting a polytetrafluoroethylene tube. The stent graft was implanted under intravascular ultrasound guidance. The 18-month angiographic follow-up showed good patency of the stent graft and complete exclusion of the aneurysm.
The Management of Superior Mesenteric Artery Aneurysm: Experience with 16 Cases in a Single Center.
Zilun, Li; Henghui, Yin; Yang, Zhao; Mian, Wang; Guangqi, Chang; Shenming, Wang
2017-07-01
Superior mesenteric artery aneurysm (SMAA) represents a rare but potentially fatal condition. This study aimed to present the individual management protocol of SMAA in our center and to discuss a potential preliminary treatment algorithm. SMAA patients treated in our center between January 2007 and December 2014 were retrospectively reviewed on January 2015. Sixteen patients with SMAA were identified, including 1 female and 15 males, with a mean age of 48.9 ± 12.9 years. Three patients (3/16, 18.8%) were treated by multiple overlapping bare stents and one (1/16, 6.3%) initially by a single bare stent. Two cases (2/16, 12.5%) were treated by a covered stent implantation, but one of those suffered from SMAA rupture 7 days later, whereas the other had inner-stent thrombosis one month after discharge and died from multiple organ-dysfunction syndrome. Nine patients (9/16, 56.2%) received conservative therapy, one of who received multiple overlapping bare stents implantations for persistent abdominal pain. One patient underwent open surgery. There were 2 major complications, with no death during hospitalization and 1 death during follow-up. SMAA treatment needs to be individually prescribed, based on clinical manifestation, anatomy, and etiology. Multiple overlapping bare stents are safe and effective in selective patients with SMAA, and covered stents should be used with caution to avoid covering proximal branches; open surgery should be reserved for patients with suspected intestinal necrosis. Copyright © 2017 Elsevier Inc. All rights reserved.
Belle, Loic; Motreff, Pascal; Mangin, Lionel; Rangé, Grégoire; Marcaggi, Xavier; Marie, Antoine; Ferrier, Nadine; Dubreuil, Olivier; Zemour, Gilles; Souteyrand, Géraud; Caussin, Christophe; Amabile, Nicolas; Isaaz, Karl; Dauphin, Raphael; Koning, René; Robin, Christophe; Faurie, Benjamin; Bonello, Laurent; Champin, Stanislas; Delhaye, Cédric; Cuilleret, François; Mewton, Nathan; Genty, Céline; Viallon, Magalie; Bosson, Jean Luc; Croisille, Pierre
2016-03-01
Delayed stent implantation after restoration of normal epicardial flow by a minimalist immediate mechanical intervention aims to decrease the rate of distal embolization and impaired myocardial reperfusion after percutaneous coronary intervention. We sought to confirm whether a delayed stenting (DS) approach (24-48 hours) improves myocardial reperfusion, versus immediate stenting, in patients with acute ST-segment-elevation myocardial infarction undergoing primary percutaneous coronary intervention. In the prospective, randomized, open-label minimalist immediate mechanical intervention (MIMI) trial, patients (n=140) with ST-segment-elevation myocardial infarction ≤12 hours were randomized to immediate stenting (n=73) or DS (n=67) after Thrombolysis In Myocardial Infarction 3 flow restoration by thrombus aspiration. Patients in the DS group underwent a second coronary arteriography for stent implantation a median of 36 hours (interquartile range 29-46) after randomization. The primary end point was microvascular obstruction (% left ventricular mass) on cardiac magnetic resonance imaging performed 5 days (interquartile range 4-6) after the first procedure. There was a nonsignificant trend toward lower microvascular obstruction in the immediate stenting group compared with DS group (1.88% versus 3.96%; P=0.051), which became significant after adjustment for the area at risk (P=0.049). Median infarct weight, left ventricular ejection fraction, and infarct size did not differ between groups. No difference in 6-month outcomes was apparent for the rate of major cardiovascular and cerebral events. The present findings do not support a strategy of DS versus immediate stenting in patients with ST-segment-elevation infarction undergoing primary percutaneous coronary intervention and even suggested a deleterious effect of DS on microvascular obstruction size. URL: http://www.clinicaltrials.gov. Unique identifier: NCT01360242. © 2016 American Heart Association, Inc.
Broken Esophageal Stent Successfully Treated by Interventional Radiology Technique
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zelenak, Kamil, E-mail: zelenak@mfn.s; Mistuna, Dusan; Lucan, Jaroslav
2010-06-15
Esophageal stent fractures occur quite rarely. A 61-year-old male patient was previously treated for rupture of benign stenosis, occurring after dilatation, by implanting an esophageal stent. However, a year after implantation, the patient suffered from dysphagia caused by the broken esophageal stent. He was treated with the interventional radiology technique, whereby a second implantation of the esophageal stent was carried out quite successfully.
Tanzilli, Gaetano; Greco, Cesare; Pelliccia, Francesco; Pasceri, Vincenzo; Barillà, Francesco; Paravati, Vincenzo; Pannitteri, Gaetano; Gaudio, Carlo; Mangieri, Enrico
2009-11-15
It remains unclear whether dual antiplatelet therapy >12 months might carry a better prognosis after percutaneous coronary intervention (PCI) with drug-eluting stents (DESs). To address the hypothesis that in the real world the risk of very late thrombosis after PCI with DESs can be decreased by an extended use of clopidogrel, we set up the Two-Year ClOpidOgrel Need (TYCOON) registry and prospectively investigated the impact on very late thrombosis of 12- versus 24-month dual antiplatelet regimens in an unselected population. The registry enrolled 897 consecutive patients who underwent PCI with stenting from January 1, 2003, to December 31, 2004, and had dual antiplatelet therapy. All patients had a 4-year clinical follow-up. In the 447 patients with DES implantation, the dual antiplatelet regimen after PCI was given for 12 months in the 173 patients treated in 2003 (12-month group) and for 24 months in the 274 patients treated in 2004 (24-month group). Comparison between groups did not reveal any significant difference in baseline clinical characteristics, angiographic and procedural features, and major adverse cardiac events. During follow-up, there were 5 cases of stent thrombosis after PCI in the 12-month DES group and 1 case in the 24-month DES group (p = 0.02). Specifically, there were 2 cases of subacute thrombosis (1 in each group), no case of late thrombosis, and 4 cases of very late thrombosis occurring at 13, 15, 17, and 23 months after DES implantation in the 12-month group only. In conclusion, a 2-year dual antiplatelet regimen with aspirin and clopidogrel can prevent the occurrence of very late stent thrombosis after PCI with DESs.
Heidland, U E; Heintzen, M P; Schoppmann, D; Michel, C J; Strauer, B E
2000-02-25
Balloon angioplasty of a stenosed bypass graft has a much higher risk of recurrent stenosis than dilatation of a stenosed native coronary artery. Intracoronary stent implantation has established itself as the better treatment of native coronary artery stenosis than conventional balloon angioplasty. However, there is still uncertainty whether intracoronary stent implantation in stenosed bypass vessels gives better long-term results than conventional balloon angioplasty. Results were retrospectively analyzed of unrandomized 224 primarily successful interventions--122 balloon dilatations and 102 stent implantations--performed between January 1996 and June 1998 on stenosed coronary bypass grafts, re-examined by coronary angiography an average of 6 months later. All but 11 patients were on combined aspirin and ticlopidine antiplatelet aggregation treatment. There was a significantly lower 6-month restenosis rate (30.4%) after stent implantation than after balloon dilatation (51.6%). The re-intervention rate was also significantly lower after stent implantation. These data suggest that stent implantation of stenosed coronary bypass grafts under cover of platelet-aggregation inhibition with aspirin and ticlopidine provides a lower restenosis and thus higher revascularization rate than conventional balloon dilatation.
LaDisa, John F; Olson, Lars E; Douglas, Hettrick A; Warltier, David C; Kersten, Judy R; Pagel, Paul S
2006-06-16
The success of stent implantation in the restoration of blood flow through areas of vascular narrowing is limited by restenosis. Several recent studies have suggested that the local geometric environment created by a deployed stent may influence regional blood flow characteristics and alter distributions of wall shear stress (WSS) after implantation, thereby rendering specific areas of the vessel wall more susceptible to neointimal hyperplasia and restenosis. Stents are most frequently implanted in curved vessels such as the coronary arteries, but most computational studies examining blood flow patterns through stented vessels conducted to date use linear, cylindrical geometric models. It appears highly probable that restenosis occurring after stent implantation in curved arteries also occurs as a consequence of changes in fluid dynamics that are established immediately after stent implantation. In the current investigation, we tested the hypothesis that acute changes in stent-induced regional geometry influence distributions of WSS using 3D coronary artery CFD models implanted with stents that either conformed to or caused straightening of the primary curvature of the left anterior descending coronary artery. WSS obtained at several intervals during the cardiac cycle, time averaged WSS, and WSS gradients were calculated using conventional techniques. Implantation of a stent that causes straightening, rather than conforms to the natural curvature of the artery causes a reduction in the radius of curvature and subsequent increase in the Dean number within the stented region. This straightening leads to modest skewing of the velocity profile at the inlet and outlet of the stented region where alterations in indices of WSS are most pronounced. For example, time-averaged WSS in the proximal portion of the stent ranged from 8.91 to 11.7 dynes/cm2 along the pericardial luminal surface and 4.26 to 4.88 dynes/cm2 along the myocardial luminal surface of curved coronary arteries as compared to 8.31 dynes/cm2 observed throughout the stented region of a straight vessel implanted with an equivalent stent. The current results predicting large spatial and temporal variations in WSS at specific locations in curved arterial 3D CFD simulations are consistent with clinically observed sites of restenosis. If the findings of this idealized study translate to the clinical situation, the regional geometry established immediately after stent implantation may predispose portions of the stented vessel to a higher risk of neointimal hyperplasia and subsequent restenosis.
Schalij, M J; Udayachalerm, W; Oemrawsingh, P; Jukema, J W; Reiber, J H; Bruschke, A V
1999-09-01
To evaluate the results of long Micro Stent II (MS-XL) implantations, 119 MS-XLs were implanted in 102 patients (age, 62.83 years). Nineteen stents (16%) were implanted in saphenous vein grafts; 100 stents (84%) were implanted in native coronary arteries. Twenty-five patients (25%) were treated because of acute myocardial infarction (AMI); 30 patients (29%) because of unstable angina or angina class IV, and 47 patients (46%) because of stable angina. Eighty-six de novo lesions (84%) and 16 restenotic lesions (16%) were treated. Indications for stent implantation include elective, 61 patients (60%); suboptimal balloon angioplasty result, 22 patients (21%); and bailout after balloon angioplasty, 19 patients (19%). Because of residual thrombus after stenting, 27 patients (26%) received abciximab. All patients received ticlopidin for 28 days and acetylsalicylic acid. One hundred and seventeen MS-XLs (98%) were implanted successfully. Additional (shorter) MS-II were implanted in 40 patients (39%). The stented segment length was 45 +/- 20 mm. The minimum lumen diameter increased from 0.5 +/- 0.5 mm before to 2.7 +/- 0.5 mm after stent implantation. The acute gain was 2.2 +/- 0.4 mm. Early clinical events (<4 weeks) include death, 3 (3%); subacute stent thrombosis, 1 (1%); non-Q-wave infarction, 2 (2%); CABG, 1 (1%); vascular complications, 2 (2%). Late clinical events (<6 months) include acute myocardial infarction, 5 (5%); reintervention, 6 (6%); CABG, 1 (1%). The procedural success rate was 88%, and the event free survival at 6 months was 76%. Stenting of long lesions with the MS-XL was successful and associated with an acceptable complication rate. Cathet. Cardiovasc. Intervent. 48:105-112, 1999. Copyright 1999 Wiley-Liss, Inc.
Finite Element Analysis of the Implantation Process of Overlapping Stents
Xu, Jiang; Yang, Jie; Sohrabi, Salman; Zhou, Yihua; Liu, Yaling
2017-01-01
Overlapping stents are widely used in vascular stent surgeries. However, the rate of stent fractures (SF) and in-stent restenosis (ISR) after using overlapping stents is higher than that of single stent implantations. Published studies investigating the nature of overlapping stents rely primarily on medical images, which can only reveal the effect of the surgery without providing insights into how stent overlap influences the implantation process. In this paper, a finite element analysis of the overlapping stent implantation process was performed to study the interaction between overlapping stents. Four different cases, based on three typical stent overlap modes and two classical balloons, were investigated. The results showed that overlapping contact patterns among struts were edge-to-edge, edge-to-surface, and noncontact. These were mainly induced by the nonuniform deformation of the stent in the radial direction and stent tubular structures. Meanwhile, the results also revealed that the contact pressure was concentrated in the edge of overlapping struts. During the stent overlap process, the contact pattern was primarily edge-to-edge contact at the beginning and edge-to-surface contact as the contact pressure increased. The interactions between overlapping stents suggest that the failure of overlapping stents frequently occurs along stent edges, which agrees with the previous experimental research regarding the safety of overlapping stents. This paper also provides a fundamental understanding of the mechanical properties of overlapping stents. PMID:28690712
Ladisa, John F; Olson, Lars E; Ropella, Kristina M; Molthen, Robert C; Haworth, Steven T; Kersten, Judy R; Warltier, David C; Pagel, Paul S
2005-08-01
Restenosis caused by neointimal hyperplasia (NH) remains an important clinical problem after stent implantation. Restenosis varies with stent geometry, and idealized computational fluid dynamics (CFD) models have indicated that geometric properties of the implanted stent may differentially influence NH. However, 3D studies capturing the in vivo flow domain within stented vessels have not been conducted at a resolution sufficient to detect subtle alterations in vascular geometry caused by the stent and the subsequent temporal development of NH. We present the details and limitations of a series of post-processing operations used in conjunction with microfocal X-ray CT imaging and reconstruction to generate geometrically accurate flow domains within the localized region of a stent several weeks after implantation. Microfocal X-ray CT reconstruction volumes were subjected to an automated program to perform arterial thresholding, spatial orientation, and surface smoothing of stented and unstented rabbit iliac arteries several weeks after antegrade implantation. A transfer function was obtained for the current post-processing methodology containing reconstructed 16 mm stents implanted into rabbit iliac arteries for up to 21 days after implantation and resolved at circumferential and axial resolutions of 32 and 50 microm, respectively. The results indicate that the techniques presented are sufficient to resolve distributions of WSS with 80% accuracy in segments containing 16 surface perturbations over a 16 mm stented region. These methods will be used to test the hypothesis that reductions in normalized wall shear stress (WSS) and increases in the spatial disparity of WSS immediately after stent implantation may spatially correlate with the temporal development of NH within the stented region.
Cui, Xiaoming; Li, Tao; Li, Xin; Zhou, Weihua
2015-05-01
The aim of this study was to evaluate the in vivo performance of four image reconstruction algorithms in a high-definition CT (HDCT) scanner with improved spatial resolution for the evaluation of coronary artery stents and intrastent lumina. Thirty-nine consecutive patients with a total of 71 implanted coronary stents underwent coronary CT angiography (CCTA) on a HDCT (Discovery CT 750 HD; GE Healthcare) with the high-resolution scanning mode. Four different reconstruction algorithms (HD-stand, HD-detail; HD-stand-plus; HD-detail-plus) were applied to reconstruct the stented coronary arteries. Image quality for stent characterization was assessed. Image noise and intrastent luminal diameter were measured. The relationship between the measurement of inner stent diameter (ISD) and the true stent diameter (TSD) and stent type were analysed. The stent-dedicated kernel (HD-detail) offered the highest percentage (53.5%) of good image quality for stent characterization and the highest ratio (68.0±8.4%) of visible stent lumen/true stent lumen for luminal diameter measurement at the expense of an increased overall image noise. The Pearson correlation coefficient between the ISD and TSD measurement and spearman correlation coefficient between the ISD measurement and stent type were 0.83 and 0.48, respectively. Compared with standard reconstruction algorithms, high-definition CT imaging technique with dedicated high-resolution reconstruction algorithm provides more accurate stent characterization and intrastent luminal diameter measurement. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang Zhongmin, E-mail: wzm0722@hotmail.co; Chen Kemin, E-mail: ckm0722@hotmail.co; Gong Ju
Many patients with malignant gastroduodenal obstruction have an unresectable primary lesion and distant metastases, which may prompt palliative management to allow the patient to eat and to improve the quality of life. Intraluminal metallic stent implantation (MSI) under fluoroscopic guidance has been reported to be an effective option for symptomatic relief in these patients, with a good safety record. An alternative, dual interventional therapy (DIT), has been used during the last decade, in which prosthesis insertion is followed by intra-arterial chemotherapy via the tumor-feeding arteries. The aim of this study was to compare success rates, complication rates, and survival timemore » between MSI and DIT in patients who presented with gastroduodenal obstruction from advanced upper gastrointestinal tract cancer. All consecutive patients with malignant gastroduodenal obstruction seen at our center between October 2002 and August 2007 were retrospectively studied. Patients were treated palliatively by either MSI or DIT by the patient's or the next of kin's decision. Outcomes included technical and clinical success, complication rates, and survival. Of the 164 patients with malignant gastric and duodenal outlet obstructions, 80 (49%) underwent stent insertion as the primary therapy, while the remaining 84 (51%) received DIT. Clinical characteristics were similar between the two groups. In the MSI cohort initial stent implantation was successful in 73 patients (91%), two stents were used in 5 patients, and delayed additional stent insertion for stent obstruction related to tumor overgrowth was required in 3 patients during follow-up. In the DIT cohort the technical success rate was 94%, 3 patients required two stents, and stent obstruction occurred in 2 patients after initial stent placement. Early postprocedural clinical success, indicated by average dysphagia score, improved significantly in both groups: MSI group, from 4.56 to 1.51 (P < 0.01); and DIT group, from 4.38 to 1.48 (p < 0.01). There were no short-term complications. Late complications including hematemesis (n = 3), migration (n = 12), and stent occlusion due to tumor overgrowth (n = 5) were evenly distributed between the groups. In the DIT group chemotherapy-induced neutropenia and transient renal dysfunction were detected in six patients, which improved after symptomatic management. Mean survival time after the procedure was 5.9 and 11.1 months for MSI and DIT, respectively (P < 0.001). In conclusion, both MSI and DIT offer effective palliation for malignant gastroduodenal obstruction, but DIT appears to offer superior survival over MSI alone. Ideally, a prospective randomized trial comparing these two techniques should be carried out to validate this result.« less
Schmidt, Arthur; Pickartz, Tilman; Lerch, Markus M; Fanelli, Fabrizio; Fiocca, Fausto; Lucatelli, Pierleone; Cereatti, Fabrizio; Hoffmeister, Albrecht; van Steenbergen, Werner; Kraft, Matthias; Meier, Benjamin
2016-01-01
Background Temporary placement of removable, fully covered, self-expandable metal stents (fcSEMS) for treatment of benign biliary strictures (BBS) has been reported to be effective. However, the optimal extraction time point remains unclear and stent migration has been a major concern. Objective The objective of this study was to evaluate the efficacy and safety of this treatment modality using an fcSEMS with a special antimigration design and prolonged stent indwell time. Methods We performed a prospective, single-arm study at six tertiary care centers in Europe. Patients with BBS underwent endoscopic or percutaneous implantation of an fcSEMS (GORE® VIABIL® Biliary Endoprosthesis, W.L. Gore & Associates, Flagstaff, AZ, USA). The devices were scheduled to be removed nine months later, and patients were to return for follow-up for an additional 15 months. Results Forty-three patients were enrolled in the study. Stricture etiology was chronic pancreatitis in the majority of patients (57.5%). All fcSEMS were placed successfully, either endoscopically (76.7%) or percutaneously (23.3%). Stent migration was observed in two patients (5.2%). Primary patency of the SEMS prior to removal was 73.0%. All attempted stent removals were successful. At removal, stricture was resolved or significantly improved without need for further therapy in 78.9% of patients. Stricture recurrence during a follow-up of two years post-implant was observed in two patients. Conclusions Temporary placement of the fcSEMS is a feasible, safe and effective treatment for BBS. The design of the device used in this study accounts for very low migration rates and facilitates easy stent retrieval, even after it has been in place for up to 11 months. PMID:28507752
Schmidt, Arthur; Pickartz, Tilman; Lerch, Markus M; Fanelli, Fabrizio; Fiocca, Fausto; Lucatelli, Pierleone; Cereatti, Fabrizio; Hoffmeister, Albrecht; van Steenbergen, Werner; Kraft, Matthias; Meier, Benjamin; Caca, Karel
2017-04-01
Temporary placement of removable, fully covered, self-expandable metal stents (fcSEMS) for treatment of benign biliary strictures (BBS) has been reported to be effective. However, the optimal extraction time point remains unclear and stent migration has been a major concern. The objective of this study was to evaluate the efficacy and safety of this treatment modality using an fcSEMS with a special antimigration design and prolonged stent indwell time. We performed a prospective, single-arm study at six tertiary care centers in Europe. Patients with BBS underwent endoscopic or percutaneous implantation of an fcSEMS (GORE® VIABIL® Biliary Endoprosthesis, W.L. Gore & Associates, Flagstaff, AZ, USA). The devices were scheduled to be removed nine months later, and patients were to return for follow-up for an additional 15 months. Forty-three patients were enrolled in the study. Stricture etiology was chronic pancreatitis in the majority of patients (57.5%). All fcSEMS were placed successfully, either endoscopically (76.7%) or percutaneously (23.3%). Stent migration was observed in two patients (5.2%). Primary patency of the SEMS prior to removal was 73.0%. All attempted stent removals were successful. At removal, stricture was resolved or significantly improved without need for further therapy in 78.9% of patients. Stricture recurrence during a follow-up of two years post-implant was observed in two patients. Temporary placement of the fcSEMS is a feasible, safe and effective treatment for BBS. The design of the device used in this study accounts for very low migration rates and facilitates easy stent retrieval, even after it has been in place for up to 11 months.
Biomechanical analysis on stent materials used as cardiovascular implants
NASA Astrophysics Data System (ADS)
Kumar, Vasantha; Ramesha, C. M.; Sajjan, Sudheer S.
2018-04-01
Atherosclerosis is the most common cause of death in the world, accounting for 48% of all deaths in the world. Atherosclerosis, also known as coronary artery disease occurs when excess cholesterol attaches itself to the walls of blood vessels. Coronary stent implantation is one of the most important procedures to treating coronary artery disease such atherosclerosis. Due to its efficiency, flexibility and simplicity, the use of coronary stents procedures has increased rapidly. In order to have better output of stent implantation, it is needed to study and analyze the biomechanical behavior of this device before manufacturing and put into use. Biomaterials are commonly used for medical application in cardiovascular stent implantation. A biomaterial is a non-viable material used as medical implant, so it is intended to interact with biological system. In this paper, an explicit dynamic analysis is used for analyzing the biomechanical behavior of cardiovascular stent by using finite element analysis tool, ABAQUS 6.10. Results showed that a best suitable biomaterial for cardiovascular stent implants, which exhibits an outstanding biocompatibility and biomechanical characteristics will be aimed at which will be quite useful to the human beings worldwide.
Malekzadeh-Milani, Sophie; Ladouceur, Magalie; Cohen, Sarah; Iserin, Laurence; Boudjemline, Younes
2014-11-01
Although widely accepted worldwide, indications for percutaneous valve replacement are limited to treatment of dysfunction of prosthetic conduits inserted in the right ventricular outflow tract (RVOT). There has been little evaluation of the use of the Melody(®) valve for patched non-circular pulmonary pathways. To evaluate the outcomes of Melody valve insertion in patients with a patched non-circular RVOT. We analysed procedural and outcomes data from 34 patients who underwent Melody valve implantation for a non-circular RVOT. RVOT preparation was done in all patients, using different techniques (conventional, Russian doll and/or PA jailing). Melody valve insertion was performed concomitantly in most patients. All procedures were successful. Sixteen patients had complex additional procedures, including the jailing technique (n=5), the Russian doll technique (n=6) and multiple stent implantations (Russian jailing; n=5). The remaining patients were treated using the conventional technique with systematic prestenting. Three early complications occurred: one haemoptysis; one residual RVOT obstruction needing recatheterization 48 hours after percutaneous pulmonary valve implantation; and one stent embolization during advancement of the Ensemble(®) delivery system. The mean follow-up period was 2.6 years postprocedure. There was no stent fracture, migration or embolization. Two patients developed a significant paraprosthetic leak and one received a second Melody valve. Careful patient selection, balloon sizing and RVOT preparation with prestenting are required to create a safe landing zone for the Melody valve. Short-term follow-up shows excellent results with no stent fracture or migration and appears promising. Copyright © 2014 Elsevier Masson SAS. All rights reserved.
Ell, C; Hochberger, J; May, A; Fleig, W E; Hahn, E G
1994-09-01
The clinical feasibility of self-expanding metal stents with respect to the technical success, complications, and reintervention rate should be tested. Five coated and 26 uncoated prototype Wallstents, especially designed for stenosis of the upper GI tract, were implanted in 23 patients. All patients with dysphagia suffered from inoperable tumor stenosis of the esophagus or the cardia. Stent implantation was performed under slight i.v. sedoanalgesia. Technical success was achieved in all 31 implanted stents. Forty-eight hr after implantation, dysphagia was improved in 21/23 patients. Acute problems observed within 1 wk were stent migration (1 patient, uncoated stent), oblique position of the stent (3 patients), epigastric or retrosternal pain (9 patients), insufficient stent expansion (4 patients), and pouch formation at the upper rim of the stent (4 patients). An uncomplicated follow-up (median 66 days, range 10-139 days) was seen in 12 patients (52%). Major problems in the follow-up period were stent migration in three patients (three coated stents, two stent migrations in one patient) and stent obstruction by tumor ingrowth/overgrowth and/or food impaction in eight patients (35%). Most of these problems could be successfully resolved by implantation of a second stent or electrocoagulation of overgrowing tumor tissue. By the 1st of March, 1994, three patients were still alive with a follow-up period of 530 days (median range, 336-880 days); 20 patients were decreased with a follow-up period of 70 days (median range, 3-374 days). Implantation of esophageal Wallstents is safe and has a low risk of acute complications and mortality for the patient. Early complications such as perforation and bleeding did not occur. Tumor ingrowth/overgrowth are the major reasons for the high reintervention rate in the follow-up period. Coated stents can resolve this problem, provided that stent migration can be avoided by improvement of the coating technology.
Bouki, Konstantina P; Sakkali, Eleni; Toutouzas, Konstantinos; Vlad, Delia; Barmperis, Dimitrios; Phychari, Stavroula; Riga, Maria; Apostolou, Thomas; Stefanadis, Christodoulos
2015-08-01
The purpose of the present study was to assess the incidence, predictors and long term prognosis of stent edge dissections identified by (OCT) after the implantation of bare metal (BMS) and drug eluting stents (DES). We studied 74 patients who underwent percutaneous coronary intervention (PCI) because of an acute coronary syndrome. Edge dissections were found in 29 of 74 patients (39.1%). Independent predictors of edge dissections were: the presence of ST-elevation myocardial infarction (STEMI) (P = 0.005, odds ratio 11.78; 95% Cl 2.06-67.10), the small reference lumen diameter (P = 0.009, odds ratio 0.11; 95% Cl 0.02-0.58) and the short stents implanted (P = 0.013, odds ratio 0.83; 95% Cl 0.72-0.96). During a follow-up period of 25.6 ± 9.4 months 11 patients presented with at least one major adverse cardiac event. Event free survival was significantly decreased in patients with edge dissection with a flap thickness >0.31 mm compared to patients with thinner flap or without any dissection (P < 0.001). OCT frequently detects edge dissections, usually related to STEMI presentation and to PCI technique. Deep vessel wall injury at stent edges with a dissection flap thickness more than 0.31mm carries an adverse clinical impact on long-term clinical outcome. © 2015 Wiley Periodicals, Inc.
Siminiak, Tomasz; Link, Rafał; Wołoszyn, Maciej; Kałmucki, Piotr; Baszko, Artur
2012-01-01
There is certain experimental and clinical evidence indicating that the covering of bare metal stents (BMS) with drug eluting polymers to produce drug eluting stents (DES) results in increased stent stiffness and modifies the mechanical properties of the stent platform. In addition, it has been speculated that the mechanical performance of DES, compared to BMS, may be related to the type of polymer used to cover stents. We aimed at evaluating the deliverability of DES with a lactate based biodegradable polymer and BMS in patients with stable coronary artery disease in a prospective randomised study. One hundred eleven consecutive patients (age: 36-77, mean 58.8 years) scheduled for routine angioplasty due to stable coronary disease were randomised to receive BMS (Chopin II(TM), Balton, Poland) or paclitaxel eluting stent (Chopin Luc(TM), Balton, Poland) using the same metal platform. Only patients scheduled for angioplasty using the direct implantation technique of a single stent were randomised. The exclusion criteria included patients 〉 80 years, multivessel disease and reference diameter of the target vessel 〉 3.5 mm. In the BMS group (n = 55; 35 males and 20 females), the mean diameter of implanted stents was 3.09 ± 0.40 and the mean length was 11.37 ± 2.80, whereas in the DES group (n = 56; 34 males and 22 females) the mean stent sizes were 3.02 ± 0.34 and 17.90 ± 7.38 mm, respectively (p 〉 0.05 for length). The groups did not significantly differ regarding the frequency of stent implantation to particular coronary vessels. The direct stenting technique was attempted and failed, leading to the stents' implantation after predilatation in five patients in the BMS group and six patients in the DES group. Failure of stent implantation and subsequent implantation of another stent type was observed in no BMS patients and in one DES patient (NS). Although stent covering with lactate based drug eluting polymer may increase its stiffness, it does not affect its deliverability in patients with stable coronary disease.
TIPS stent migration into the heart with 6-year follow-up.
Fehervari, Imre; Szonyi, Laszlo; Fazakas, Janos; Gerlei, Zsuzsa; Lazar, Istvan
2011-01-01
The transjugular intrahepatic portosystemic shunt (TIPS) is widely used for the treatment of portal hypertension in adults, but no studies have defined the best approach to treat portal hypertension in pediatric patients. Pediatric use of TIPS is rare even in large centers of adult practice. The migration of stents has also been reported as a complication in adults. There is no standard way to treat this type of complication, and it is not always clear whether immediate removal or watchful waiting is safer for the patient. We report the case of an 11-year-old patient who underwent urgent TIPS implantation due to variceal bleeding, after unsuccessful sclerotherapy. During the procedure, due to the deep impact of the stent, a second, telescopic, stent was inserted. The portal pressure decreased, no further bleeding occurred, and the patient was listed for transplantation. Three weeks later a routine chest X-ray discovered the migration of the second stent into the right ventricle. No interventional radiological removal or open heart surgery was available for the transplant waiting list patient. The patient underwent uneventful combined liver-kidney transplantation. During the 6-year follow-up period the child had no signs of hemodynamic instability, and his somatic and mental development were appropriate. To our knowledge this case is the first publication on a heart-impacted TIPS stent in a child. The watchful waiting was justified by uneventful combined liver-kidney transplantation and long-term follow-up. This case also underlines the need for best practice guidelines in pediatric portal hypertension.
Sultan, Sherif; Kavanagh, Edel P; Hynes, Niamh; Diethrich, Edward B
2016-02-01
This study outlines the use of non-aneurysmal porcine animal models to study device functionality and biological response of the Multilayer Flow Modulator (MFM) (Cardiatis, Isnes, Belgium), with an emphasis on preclinical device functionality and biological response characteristics in an otherwise healthy aorta. Twelve animals were implanted with the study device in the abdominal aorta, in 6 animals for 1 month and 6 animals for 6 months. Upon completion of the study period, each animal underwent a necropsy to examine how the implanted device had affected the artery and surrounding tissue. Neointima and stenosis formation were recorded via morphometry, and endothelialization via histopathological analysis. The MFM devices were delivered to their respective implantation sites without difficulty. Six of the implanted stents were oversized with percentages ranging from 2.6% to 18.8%. Statistical analysis was carried out and showed no significance between the regular sized stent group and oversized stent group for neointimal area (P=0.17), neointimal thickness (P=0.17), and percentage area stenosis (P=0.65). Histopathological findings showed in most areas flattened endothelium like cells lined the luminal surface of the neointima. Scanning electron microscopy also showed the devices were well tolerated, inciting only a minimal neointimal covering and little fibrin or platelet deposition. Neointimal thickness of 239.7±55.6 μm and 318.3±130.4 μm, and percentage area stenosis of 9.6±2.6% and 12.6±5% were recorded at 1 and 6 months respectively. No statistical differences were found between these results. The MFM devices were delivered to their respective implantation sites without difficulty and incited little neointimal and stenosis formation in the aorta, affirming its functionality and biocompatibility.
Ishihara, Takayuki; Iida, Osamu; Inoue, Katsumi; Fujita, Masashi; Masuda, Masaharu; Okamoto, Shin; Nanto, Kiyonori; Kanda, Takashi; Tsujimura, Takuya; Sunaga, Akihiro; Mano, Toshiaki; Uematsu, Masaaki
2017-10-01
To report histological examination of a Viabahn stent-graft implanted in the superficial femoral artery (SFA) for nearly 2 years. A 78-year-old man with peripheral artery disease was treated successfully with a 6.0×250-mm Viabahn self-expanding stent-graft in the right SFA, relieving his lower limb claudication. The patient died suddenly due to acute myocardial infarction 23 months later. Histological evaluation of the stent-graft implantation site revealed moderate neointimal proliferation at both proximal and distal edges of the device. In the middle part of the stent, significant macrophages and multinucleated foreign body giant cells had accumulated, although the stent was entirely patent. Furthermore, no endothelial cell coverage was found. Judging from these features, it might be necessary to continue dual antiplatelet therapy after stent-graft implantation over the long term to prevent thrombosis and subsequent restenosis or reocclusion.
Direct comparison of the short-term clinical performance of Z Guidant and Taxus stents.
Guildford, Anna; Colombo, Paola; Bruschi, Giuseppe; Bonacina, Edgardo; Klugmann, Silvio; Santin, Matteo
2010-12-03
The recent introduction of drug-eluting stents in angioplasty of atherosclerotic blood vessels has significantly reduced the risks of in-stent restenosis (ISR) [1]. Indeed, it is known that in conventional stents ISR takes place in over 20% of the cases and up to 60% when implanted in diabetic patients. Conversely, clinical trials have shown that drug-eluting stents have significantly reduced ISR. Among the drug-eluting stents available on the market, Taxus stents (Tax, Boston Scientific, USA) are among the most used devices [2]. Tax are stainless-steel stents coated with Translute, a poly(styrene-b-isobutylene-b-styrene) polymer (PSIBS) eluting Placlitaxel, an anti-mitotic drug. Clinical trials on this type of drug-eluting stents have shown an incidence of restenosis of approximately 4%. The majority of these trials were randomized studies where conventional stents and drug-eluting devices have been implanted in separate patients' cohorts. Such a randomized design, although fundamental to collect statistically-relevant data, does not allow a direct histological comparison of different stent types when implanted in the same patient and do not show the individual susceptibility to the host response especially at short-term implantation times. Here, an interesting case study is presented where two chrome-cobalt stents (Z Guidant, ZG, Guidant Corp.) and a Tax have been simultaneously implanted in the same patient in three separate coronary arteries, retrieved after only 8 weeks and histologically analysed. Copyright © 2009 Elsevier Ireland Ltd. All rights reserved.
Callahan, Ryan; Bergersen, Lisa; Baird, Christopher W; Porras, Diego; Esch, Jesse J; Lock, James E; Marshall, Audrey C
2017-01-01
Background: Surgical and transcatheter bioprosthetic valves (BPVs) in the pulmonary position in patients with congenital heart disease may ultimately fail and undergo transcatheter reintervention. Angiographic assessment of the mechanism of BPV failure has not been previously described. Aims: The aim of this study was to determine the mode of BPV failure (stenosis/regurgitation) requiring transcatheter reintervention and to describe the angiographic characteristics of the failed BPVs and report the types and efficacy of reinterventions. Materials and Methods: This is a retrospective single-center review of consecutive patients who previously underwent pulmonary BPV placement (surgical or transcatheter) and subsequently underwent percutaneous reintervention from 2005 to 2014. Results: Fifty-five patients with surgical (41) and transcutaneous pulmonary valve (TPV) (14) implantation of BPVs underwent 66 catheter reinterventions. The surgically implanted valves underwent fifty reinterventions for indications including 16 for stenosis, seven for regurgitation, and 27 for both, predominantly associated with leaflet immobility, calcification, and thickening. Among TPVs, pulmonary stenosis (PS) was the exclusive failure mode, mainly due to loss of stent integrity (10) and endocarditis (4). Following reintervention, there was a reduction of right ventricular outflow tract gradient from 43 ± 16 mmHg to 16 ± 10 mmHg (P < 0.001) and RVp/AO ratio from 0.8 ± 0.2 to 0.5 ± 0.2 (P < 0.001). Reintervention with TPV placement was performed in 45 (82%) patients (34 surgical, 11 transcatheter) with no significant postintervention regurgitation or paravalvular leak. Conclusion: Failing surgically implanted BPVs demonstrate leaflet calcification, thickness, and immobility leading to PS and/or regurgitation while the mechanism of TPV failure in the short- to mid-term is stenosis, mainly from loss of stent integrity. This can be effectively treated with a catheter-based approach, predominantly with the valve-in-valve technique. PMID:28163423
Inverse Relationship between Serum VEGF Levels and Late In-Stent Restenosis of Drug-Eluting Stents
Shen, Li; Ji, Meng; Cai, Sishi; Chen, Jiahui; Yao, Zhifeng
2017-01-01
Late in-stent restenosis (ISR) has raised concerns regarding the long-term efficacy of drug-eluting stents (DES). The role of vascular endothelial growth factor (VEGF) in the pathological process of ISR is controversial. This retrospective study aimed to investigate the relationship between serum VEGF levels and late ISR in patients with DES implantation. A total of 158 patients who underwent angiography follow-up beyond 1 year after intervention were included. The study population was classified into ISR and non-ISR groups. The ISR group was further divided according to follow-up duration and Mehran classification. VEGF levels were significantly lower in the ISR group than in the non-ISR group [96.34 (48.18, 174.14) versus 179.14 (93.59, 307.74) pg/mL, p < 0.0001]. Multivariate regression revealed that VEGF level, procedure age, and low-density lipoprotein cholesterol were independent risk factors for late ISR formation. Subgroup analysis demonstrated that VEGF levels were even lower in the very late (≥5 years) and diffuse ISR group (Mehran patterns II, III, and IV) than in the late ISR group (1–4 years) and the focal ISR group (Mehran pattern I), respectively. Furthermore, significant difference was found between diffuse and focal ISR groups. Serum VEGF levels were inversely associated with late ISR after DES implantation. PMID:28373989
Thuesen, Leif; Galløe, Anders; Thayssen, Per; Rasmussen, Klaus; Kelbæk, Henning; Lassen, Jens Flensted; Hansen, Peter Riis; Pedersen, Knud Erik; Ravkilde, Jan; Helquist, Steffen; Abildgaard, Ulrik; Andersen, Henning Rud; Bøtker, Hans Erik; Kristensen, Steen Dalby; Hjort, Jacob; Krusell, Lars Romer
2005-11-01
To compare deliverability and in-hospital complications in implantation of BxSonic(R), Express(R), and Flexmaster(R) coronary stents in a randomized multicenter trial in five Danish interventional centres. Patients with planned stenting of at least one stenotic lesion in a native coronary artery were included in the study. There were 494 (664) patients (treated lesions) in the BxSonic(R), 499 (657) in the Express(R) and 500 (658) in the Flexmaster(R) groups. The groups were well matched with regard to age, sex, diabetes, smoking, hypercholesterolemia, hypertension, indication for PCI and coronary artery lesion complexity. The study stents were implanted with or without predilatation according to ordinary -clinical practice.Rates of successful stent implantation and in-hospital stent thrombosis, re-intervention, non-fatal myocardial infarction or death. The BxSonic(R), Express(R) and Flexmaster(R) stents were successfully implanted in 92,2%, 89,3% and 91,6% of all lesions (ns). There were no in-hospital deaths and the rates of in-hospital complications were similar in the three stent groups. We found similar deliverability and in-hospital complication rates of the BxSonic(R), Express(R) and Flexmaster(R) stents.
Ferri, Luca A; Jabbour, Richard J; Giannini, Francesco; Benincasa, Susanna; Ancona, Marco; Regazzoli, Damiano; Mangieri, Antonio; Montorfano, Matteo; Colombo, Antonio; Latib, Azeem
2017-08-01
Coronary stent underexpansion is a known risk factor for in-stent restenosis and stent thrombosis. There are limited options once noncompliant balloons have failed to achieve optimal stent expansion. Excimer Laser Coronary Angioplasty with contrast medium injection is one possibility, but not readily available. Rotational atherectomy is an alternative, and has been described in case reports, but concerns exist regarding safety. All consecutive patients undergoing rotational atherectomy for symptomatic in-stent restenosis due to stent underexpansion resistant to noncompliant balloon postdilatation between January 2005 and December 2015 were analysed. A total of 16 patients underwent treatment during the study period and the procedure was successful in 14 cases (87.5%). The mean postprocedural minimal lumen diameter increased by 2.3 ± 0.8 mm and percentage diameter stenosis decreased from 82.17% ± 17.2% to 11.9% ± 9.1%. Intraprocedural complications occurred in two patients (burr entrapment successfully managed percutaneously and periprocedural myocardial infarction). At 1-year follow-up, the incidence of target lesion revascularisation was 13.3% (2 out of 15 patients), and one patient died from noncardiac death. In this small series of underexpanded stents, rotational atherectomy was an effective treatment for resistant stent underexpansion with acceptable outcomes. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Barbagli, Guido; Rimondi, Claudio; Balò, Sofia; Butnaru, Denis; Sansalone, Salvatore; Lazzeri, Massimo
2017-09-01
To evaluate the efficacy of the Memokath stent in managing recurrent bulbar urethral strictures. This is an investigative pilot stage 2A study in patients with a recurrent bulbar urethral stricture who underwent a Memokath stent implant from January 2014 to January 2016 in a single high-volume center for urethral reconstruction. The Memokath stent (Pnn Medical A/S, Kvistgaard, Denmark) was manufactured from nitinol, a biocompatible alloy of nickel and titanium, which was endoscopically placed. It had a 24-Fr outside diameter and was preloaded on a disposable delivery device. When correctly positioned, the stent was anchored by a warm water (55°C) instillation, which expanded the proximal end of the stent from 24 to 42 Fr .The stent was provided in lengths of 3-7 cm in 1-cm increments. Sixteen patients were included in the study. The median follow-up was 16 months. In 7 patients (43.7%), the stent was removed within 1 year. The main adverse events were pain, encrustations, stones, and recurrent strictures. Four patients (25%) were considered a success and 12 (75%) were failures. Study limitations include the small sample. The Memokath stent was deemed to be not clinically helpful and had significant side effects, and therefore should not be considered a treatment option for men with bulbar urethral strictures. Copyright © 2017 Elsevier Inc. All rights reserved.
Austin, David; Oldroyd, Keith G; McConnachie, Alex; Slack, Rachel; Eteiba, Hany; Flapan, Andrew D; Jennings, Kevin P; Northcote, Robin J; Pell, Alastair C H; Starkey, Ian R; Pell, Jill P
2008-08-01
The US Food and Drug Administration recently concluded that data on off-label drug-eluting stent (DES) safety are limited. However, in actual clinical practice, DES are often used for off-label indications, and observational studies demonstrate that complications are higher when compared with on-label use. We aimed to determine whether clinical outcomes differ after DES and bare-metal stent implantation in a patient cohort defined by DES off-label indications. We used the national revascularization registry in Scotland to identify patients who underwent coronary stenting for an off-label indication between January 2003 and September 2005. Individual-level linkage to comprehensive national admission and death databases was used to ascertain the end points of death, myocardial infarction, and target-vessel revascularization. We calculated propensity scores on the basis of clinical, demographic, and angiographic variables and matched DES to bare-metal stents on a 1:1 basis. The final study population consisted of 1642 patients, well matched for important covariables at baseline. Event-free survival was calculated over 24 months with the Kaplan-Meier method. All-cause death was more common after bare-metal stent implantation during follow-up (7.7% versus 6.6%; hazard ratio 0.63; 95% confidence interval, 0.40 to 0.99; P=0.04). No difference in the rates of myocardial infarction were noted (7.3% versus 7.5%; hazard ratio 1.02; 95% confidence interval, 0.69 to 1.54; P=0.92). Target-vessel revascularization was reduced in patients treated with DES (13.9% versus 10.7%; hazard ratio 0.67; 95% confidence interval, 0.49 to 0.93; P=0.02). At 24 months, patients treated with DES for off-label indications had lower rates of death and target-vessel revascularization and similar rates of myocardial infarction, as compared with patients treated with bare-metal stents.
Zhang, Chao; Chen, Bing; Gu, Yongquan; Luo, Tao; Yang, Shengjia; Liang, Weitao; Wang, Zhonggao
2014-09-12
Tuberculous pseudoaneurysm of the aorta is rare and exposes patients to a very high risk of unpredictable rupture. To our best knowledge, only 32 cases have been reported related to all arterial systems from 1993 to 2013 in the literature. We report a 44-year-old male who presented with an aortic pseudoaneurysm and tuberculosis of the kidney and vertebrae. He underwent endovascular repair and antibiotic therapy for tuberculosis, combined with a bare stent implanted to seal endoleaks after endograft stenting. The postoperative course was uneventful and the patient recovered and lived well afterwards. Epidemiology, pathogenesis, presentation, management, and mortality of this entity were reviewed and discussed.
McElhinney, Doff B.; Bergersen, Lisa; Marshall, Audrey C.
2014-01-01
Background One of the most common uses of stents in patients with congenitally malformed hearts is treatment of pulmonary arterial stenosis. Although there are reports of fractured pulmonary arterial stents, little is known about the risk factors for, and implications of, such fractures. Methods We reviewed angiograms to identify fractures in stents previously inserted to relieve stenoses in pulmonary arteries from 1990 through 2001 in patients who also underwent follow-up catheterization at least 3 years after placement of the stent. We undertook matched cohort analysis, matching a ratio of 2 fractured to 1 unfractured stent. Results Overall, 166 stents meeting the criterions of our study had been placed in 120 patients. We identified fractures in 35 stents (21%) in 29 patients. All fractured stents were in the central pulmonary arteries, 24 (69%) in the central part of the right pulmonary artery, and all were complete axial fractures, or complex fractures along at least 2 planes. Stent-related factors associated with increased risk of fracture identified by multivariable logistic regression included placement in close apposition to the ascending aorta (p = 0.001), and a larger expanded diameter (p = 0.002). There was obstruction across 28 of 35 fractured stents, which was severe in 11. We re-stented 21 of the fractured stents, and recurrent fracture was later diagnosed in 3 of these. A fragment of the fractured stent embolized distally in 2 patients, without clinically important effects. Conclusions In situ fracture of pulmonary arterial stents is relatively common, and in most cases is related to compression by the aorta. There is usually recurrent obstruction across the fractured stent, but fractured stents rarely embolize, and are not associated with other significant complications. PMID:18559137
Bai, Ai-Guo; Zheng, Chuan-Sheng; Zhou, Guo-Feng; Liang, Hui-Min; Feng, Gan-Sheng
2010-06-01
To summarize and compare the short-term and long-term clinical efficacy of percutaneous transhepatic biliary drainage (PTBD) and percutaneous transhepatic biliary stent (PTBS) in the treatment of malignant obstructive jaundice. 210 cases of malignant obstructive jaundice underwent interventional therapy, of which 161 cases of drainage catheters placement and 49 cases of metallic stent implantation. Follow-up information was obtained through telephone review or check-up records. The technical success rate of technique was 100%. At 3 - 5 days after treatment, the serum total bilirubin in 15 metallic stent-treated patients was decreased by (178.04 +/- 42.32) micromol/L, and direct bilirubin by (83.97 +/- 23.63) micromol/L. Compared with those of 28 cases treated with drainage catheters: (95.67 +/- 34.28) micromol/L and (49.84 +/- 28.21) micromol/L, there were statistically significant differences between the two groups (P = 0.017 and P = 0.035). At 6 - 9 days after treatment, the serum total bilirubin in 28 cases of metallic stent group was decreased by (188.22 +/- 79.90) micromol/L, and that in 126 cases of drainage catheter group decreased by (141.39 +/- 65.32) micromol/L. The difference was statistically significant (P = 0.014). But the decline value of direct bilirubin had no significant difference. The median patency period and the median survival time of the drainage catheter group were 60 and 148 days, respectively, those of metallic stent group were 197 days and 245 days. There were statistically significant differences between the two groups (P < 0.05). The results of this study indicate that the short-term and long-term efficacies of metallic stent implantation are better than those of catheter drainage technique.
[Eight Cases of Esophagus and Tracheobronchial Stenting for Advanced Esophageal Cancer].
Nakahara, Yujiro; Takachi, Ko; Tsujimura, Naoto; Wakasugi, Masaki; Hirota, Masaki; Matsumoto, Takashi; Takemoto, Hiroyoshi; Nishioka, Kiyonori; Oshima, Satoshi
2017-11-01
Malignant stricture and fistula of the esophagus and tracheobronchus adversely affect the quality of life(QOL)in patients with advanced esophageal cancer. Stenting is one ofthe therapies available for these patients. We investigated the outcomes ofesophagus and tracheobronchial stenting in our institution. Eight patients with advanced esophageal cancer underwent double stenting from 2010 to 2016. Among them, 4 patients underwent double stenting as planned. One patient underwent an emergency tracheal stenting because ofstenosis ofthe trachea caused by esophageal stenting. Three patients underwent tracheobronchial stenting later on because ofan increase in the tumor size after esophageal stenting. Dysphagia score was improved in 5(67.5%)out ofthe 8 patients. Respiratory symptoms were improved in all patients, and 4 patients(50.0%) were discharged. The median survival time after esophageal stenting was 70.5 days. Esophagus and tracheobronchial stenting for advanced esophageal cancer was useful for the improvement of the QOL.
Nickel-free stainless steel avoids neointima formation following coronary stent implantation
Fujiu, Katsuhito; Manabe, Ichiro; Sasaki, Makoto; Inoue, Motoki; Iwata, Hiroshi; Hasumi, Eriko; Komuro, Issei; Katada, Yasuyuki; Taguchi, Tetsushi; Nagai, Ryozo
2012-01-01
SUS316L stainless steel and cobalt–chromium and platinum–chromium alloys are widely used platforms for coronary stents. These alloys also contain nickel (Ni), which reportedly induces allergic reactions in some subjects and is known to have various cellular effects. The effects of Ni on neointima formation after stent implantation remain unknown, however. We developed coronary stents made of Ni-free high-nitrogen austenitic stainless steel prepared using a N2-gas pressurized electroslag remelting (P-ESR) process. Neointima formation and inflammatory responses following stent implantation in porcine coronary arteries were then compared between the Ni-free and SUS316L stainless steel stents. We found significantly less neointima formation and inflammation in arteries implanted with Ni-free stents, as compared to SUS316L stents. Notably, Ni2+ was eluted into the medium from SUS316L but not from Ni-free stainless steel. Mechanistically, Ni2+ increased levels of hypoxia inducible factor protein-1α (HIF-1α) and its target genes in cultured smooth muscle cells. HIF-1α and their target gene levels were also increased in the vascular wall at SUS316L stent sites but not at Ni-free stent sites. The Ni-free stainless steel coronary stent reduces neointima formation, in part by avoiding activation of inflammatory processes via the Ni-HIF pathway. The Ni-free-stainless steel stent is a promising new coronary stent platform. PMID:27877545
Nickel-free stainless steel avoids neointima formation following coronary stent implantation.
Fujiu, Katsuhito; Manabe, Ichiro; Sasaki, Makoto; Inoue, Motoki; Iwata, Hiroshi; Hasumi, Eriko; Komuro, Issei; Katada, Yasuyuki; Taguchi, Tetsushi; Nagai, Ryozo
2012-12-01
SUS316L stainless steel and cobalt-chromium and platinum-chromium alloys are widely used platforms for coronary stents. These alloys also contain nickel (Ni), which reportedly induces allergic reactions in some subjects and is known to have various cellular effects. The effects of Ni on neointima formation after stent implantation remain unknown, however. We developed coronary stents made of Ni-free high-nitrogen austenitic stainless steel prepared using a N 2 -gas pressurized electroslag remelting (P-ESR) process. Neointima formation and inflammatory responses following stent implantation in porcine coronary arteries were then compared between the Ni-free and SUS316L stainless steel stents. We found significantly less neointima formation and inflammation in arteries implanted with Ni-free stents, as compared to SUS316L stents. Notably, Ni 2+ was eluted into the medium from SUS316L but not from Ni-free stainless steel. Mechanistically, Ni 2+ increased levels of hypoxia inducible factor protein-1 α (HIF-1 α ) and its target genes in cultured smooth muscle cells. HIF-1 α and their target gene levels were also increased in the vascular wall at SUS316L stent sites but not at Ni-free stent sites. The Ni-free stainless steel coronary stent reduces neointima formation, in part by avoiding activation of inflammatory processes via the Ni-HIF pathway. The Ni-free-stainless steel stent is a promising new coronary stent platform.
Voskanyan, Lilit; García-Feijoó, Julián; Belda, Jose I; Fea, Antonio; Jünemann, Anselm; Baudouin, Christophe
2014-02-01
Micro-invasive glaucoma surgical implantation of trabecular micro-bypass stents, previously shown to be safe and effective for open-angle glaucoma (OAG) subjects during cataract surgery, was considered for evaluation as a sole procedure. The aim of this study was to evaluate the safety and intraocular pressure (IOP)-lowering efficacy after ab interno implantation of two Glaukos Trabecular Micro-Bypass iStent inject second generation devices in subjects with OAG. This study was performed at sites in France, Germany, Italy, Republic of Armenia, and Spain. In this pan-European, multi-center prospective, post-market, unmasked study, 99 patients with OAG on at least two topical ocular hypotensive medications who required additional IOP lowering to control glaucoma disease underwent implantation of two GTS400 stents in a stand-alone procedure. Patients were qualified if they presented with preoperative mean IOP between 22 and 38 mmHg after medication washout. Postoperatively, subjects were assessed at Day 1, Months 1, 3, 6, 7, 9, and 12. IOP, medication use and safety were assessed at each visit. Sixty-six percent of subjects achieved IOP ≤18 mmHg at 12 months without medication, and 81% of subjects achieved Month 12 IOP ≤ 18 mmHg with either a single medication or no medication. Mean baseline washout IOP values decreased by 10.2 mmHg or 39.7% from 26.3 (SD 3.5) mmHg to 15.7 (SD 3.7) mmHg at Month 12. Mean IOP at 12 months was 14.7 (SD 3.1) mmHg in subjects not using ocular hypotensive medications. Reduction from preoperative medication burden was achieved in 86.9% of patients, including 15.2% with reduction of one medication and 71.7% with reduction of two or more medications. Postoperative complications occurred at a low rate and resolved without persistent effects. In this series, implantation of two trabecular micro-bypass second generation stents in subjects with OAG resulted in IOP and medication reduction and favorable safety outcomes.
Enterprise Deployment Through PulseRider To Treat Anterior Communicating Artery Aneurysm Recurrence.
Valente, Iacopo; Limbucci, Nicola; Nappini, Sergio; Rosi, Andrea; Laiso, Antonio; Mangiafico, Salvatore
2018-02-01
PulseRider (Pulsar Vascular, Los Gatos, California, USA) is a new endovascular device designed to treat wide-neck bifurcation intracranial aneurysms. Deployment of a stent through a PulseRider to treat an aneurysm's recurrence has never been described before. We report the case of a 55-year-old man who underwent coiling of an 8-mm anterior communicating artery aneurysm with assistance of a PulseRider neck reconstruction device. The 6-month digital subtraction angiography control showed aneurysm recurrence, so we deployed an Enterprise 2 closed-cell stent (Codman, Miami Lakes, Florida, USA) in the A1-A2 segment passing across the previously implanted PulseRider. Enterprise correctly expanded and allowed for adequate coiling of the aneurysm. An Enterprise stent can be safely opened through a PulseRider in order to treat aneurysm recurrence. Copyright © 2017 Elsevier Inc. All rights reserved.
Bruining, Nico; Tanimoto, Shuzou; Otsuka, Masato; Weustink, Annick; Ligthart, Jurgen; de Winter, Sebastiaan; van Mieghem, Carlos; Nieman, Koen; de Feyter, Pim J; van Domburg, Ron T; Serruys, Patrick W
2008-08-01
To investigate if three-dimensional (3D) based quantitative techniques are comparable to each other and to explore possible differences with respect to the reference method of 2D-QCA in the acute phase and to study whether non-invasive MSCT could potentially be applied to quantify luminal dimensions of a stented coronary segment with a novel bioabsorable drug-eluting stent made of poly-l-lactic-acid (PLLA). Quantitative imaging data derived from 16 patients enrolled at our institution in a first-in-man trial (ABSORB) receiving a biodegradable stent and who were imaged with standard coronary angiography and intravascular ultrasound were compared. Shortly, after stenting the patients also underwent a MSCT procedure. Standard 2D-QCA showed significant smaller stent lengths (p < 0.01). Although, the absolute measured stent diameters and areas by 2D-QCA tend to be smaller, the differences failed to be statistically different when compared to the 3D based quantitative modalities. Measurements made by non-invasive QMSCT-CA of implanted PLLA stents appeared to be comparable to the other 3D modalities without significant differences. Three-dimensional based quantitative analyses showed similar results quantifying luminal dimensions as compared to 2D-QCA during an evaluation of a new bioabsorbable coronary stent design in the acute phase. Furthermore, in biodegradable stents made of PLLA, non-invasive QMSCT-CA can be used to quantify luminal dimensions.
Immediate outcomes of eptifibatide therapy during intracoronary stent implantation.
Shariati, Hooman; Sanei, Hamid; Pourmoghadas, Ali; Salehizadeh, Leila; Amirpour, Afshin
2016-01-01
The objective of the present study was to assess the major immediate outcomes of eptifibatide therapy during intracoronary stent implantation. In an interventional study, patients undergoing percutaneous coronary intervention (PCI) were randomized into either the eptifibatide ( n = 100) or the control ( n = 107) group. In each group, demographic and clinical characteristics such as cardiac death, stent thrombosis (ST), myocardial infarction (MI), rates of target lesion and vessel revascularization, cerebral vascular accident (CVA), and emergency coronary artery bypass grafting (CABG) were recorded. The overall rates of major adverse events such as mortality, Stent thrombosis (ST), Myocardial Infarction (MI), target lesion revascularization (TLR), target vessel revascularization (TVR), CVA, and emergency CABG within 24 h after stent implantation were low and comparable between the two groups; P > 0.05 considered significant for all comparisons. There were no statistical differences between the clinical outcomes of groups administered with single-dose intracoronary eptifibatide and control groups among patients undergoing PCI during stent implantation.
A new thermal shape memory Ti-Ni alloy stent covered with silicone.
Nakamura, T; Shimizu, Y; Ito, Y; Matsui, T; Okumura, N; Takimoto, Y; Ariyasu, T; Kiyotani, T
1992-01-01
An attempt was made to develop an airway stent for nonsurgical transluminal implantation using a bronchofiberscope. The stent is composed of a single wire with a diameter of 0.5 mm. The wire is made of thermal shape memory titanium nickel alloy, with a transition temperature of 25-30 degrees C. To avoid direct contact between the metal and the tissue, the wire is covered with a 300 microns thick coating of silicone. The stent is horseshoe shaped in cross-section. It is 15 mm in outer transverse diameter and 40 mm long. Ten stents were implanted in 10 dogs whose tracheal cartilages had been previously broken. The stents were first cooled in ice water to reduce their diameter and then inserted into the target site. The wire was warmed to body temperature and recovered its initial shape within 10 sec. The dogs were killed for examination between 1 week and 6 months after implantation. All the stents were located at the implantation sites and were patent. Tissue reactions, such as ulceration and granulation formation, were less severe than in those with previously implanted non-silicone covered stents. Microscopic observation showed that the wires became gradually covered with epithelium within 2 months. This transluminal technique for preserving airway patency shows promise for clinical application.
Efficacy and Safety of Dual Antiplatelet Therapy After Complex PCI.
Giustino, Gennaro; Chieffo, Alaide; Palmerini, Tullio; Valgimigli, Marco; Feres, Fausto; Abizaid, Alexandre; Costa, Ricardo A; Hong, Myeong-Ki; Kim, Byeong-Keuk; Jang, Yangsoo; Kim, Hyo-Soo; Park, Kyung Woo; Gilard, Martine; Morice, Marie-Claude; Sawaya, Fadi; Sardella, Gennaro; Genereux, Philippe; Redfors, Bjorn; Leon, Martin B; Bhatt, Deepak L; Stone, Gregg W; Colombo, Antonio
2016-10-25
Optimal upfront dual antiplatelet therapy (DAPT) duration after complex percutaneous coronary intervention (PCI) with drug-eluting stents (DES) remains unclear. This study investigated the efficacy and safety of long-term (≥12 months) versus short-term (3 or 6 months) DAPT with aspirin and clopidogrel according to PCI complexity. The authors pooled patient-level data from 6 randomized controlled trials investigating DAPT durations after PCI. Complex PCI was defined as having at least 1 of the following features: 3 vessels treated, ≥3 stents implanted, ≥3 lesions treated, bifurcation with 2 stents implanted, total stent length >60 mm, or chronic total occlusion. The primary efficacy endpoint was major adverse cardiac events (MACE), defined as the composite of cardiac death, myocardial infarction, or stent thrombosis. The primary safety endpoint was major bleeding. Intention-to-treat was the primary analytic approach. Of 9,577 patients included in the pooled dataset for whom procedural variables were available, 1,680 (17.5%) underwent complex PCI. Overall, 85% of patients received new-generation DES. At a median follow-up time of 392 days (interquartile range: 366 to 710 days), patients who underwent complex PCI had a higher risk of MACE (adjusted hazard ratio [HR]: 1.98; 95% confidence interval [CI]: 1.50 to 2.60; p < 0.0001). Compared with short-term DAPT, long-term DAPT yielded significant reductions in MACE in the complex PCI group (adjusted HR: 0.56; 95% CI: 0.35 to 0.89) versus the noncomplex PCI group (adjusted HR: 1.01; 95% CI: 0.75 to 1.35; p interaction = 0.01). The magnitude of the benefit with long-term DAPT was progressively greater per increase in procedural complexity. Long-term DAPT was associated with increased risk for major bleeding, which was similar between groups (p interaction = 0.96). Results were consistent by per-treatment landmark analysis. Alongside other established clinical risk factors, procedural complexity is an important parameter to take into account in tailoring upfront duration of DAPT. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Yu, Jae-Jung; Kim, Gyu-Tae; Choi, Yong-Suk; Hwang, Eui-Hwan; Paek, Janghyun; Kim, Seong-Hun; Huang, John C
2012-03-01
To validate the accuracy of a cone-beam computed tomography (CBCT)-guided surgical stent for orthodontic mini-implant (OMI) placement by quantitatively evaluating the difference between CBCT-prescribed and actual position of mini-implants in preoperative and postoperative CBCT images. A surgical stent was fabricated using Teflon-Perfluoroalkoxy, which has appropriate biological x-ray attenuation properties. Polyvinylsiloxane impression material was used to secure the custom-made surgical stent onto swine mandibles. CBCT scanning was done with the stent in place to virtually plan mini-implants using a three-dimensional (3D) software program. An appropriate insertion point was determined using 3D reconstruction data, and the vertical and horizontal angulations were determined using four prescribed angles. A custom-designed surveyor was used to drill a guide hole within the surgical stent as prescribed on the CBCT images for insertion of 32 OMIs. The mandibles with a surgical stent in place were rescanned with CBCT to measure the deviations between the virtual planning data and surgical results. The difference between the prescribed and actual vertical angle was 1.01 ± 7.25, and the horizontal difference was 1.16 ± 6.08. The correlation coefficient confirms that there was no intrarater variability in either the horizontal (R = .97) or vertical (R = .74) vectors. The surgical stent in this study guides mini-implants to the prescribed position as planned in CBCT. Since the statistical difference was not significant, the surgical stent can be considered to be an accurate guide tool for mini-implant placement in clinical use.
Édes, István F.; Ruzsa, Zoltán; Szabó, György; Nardai, Sándor; Becker, Dávid; Benke, Kálmán; Szilveszter, Bálint
2015-01-01
Objectives Our aim was to assess the procedural success and determine the clinical predictors of postprocedure mortality, following rotational atherectomy (RA) and stenting in high‐risk patients. Background RA is mainly used to facilitate stenting in complex lesions. Outcomes involving RA and stenting have been investigated, yet high‐risk patients have not been adequately described. Methods Data of 218 consecutive patients who underwent RA were evaluated in a prospective register. Primary endpoints were the angiographic success and long‐term mortality. Secondary endpoints were procedural success, consumption of the angioplasty equipment, and periprocedural major adverse cardiac events. The impact of the relevant angiographic and clinical characteristics on long‐term mortality was analyzed using uni‐ and multivariate Cox regression analysis. Results Mean age of the patients was 70 ± 8.2 years, diabetes was present in 44%, and chronic renal failure in 29%. Prior myocardial infarction and three‐vessel disease amounted to 42.2% and 32.6%, respectively. Altogether, 52.8% of patients underwent RA after a failed, non‐RA intervention attempt, and 30.7% of cases presented as acute coronary syndromes. Angiographic success was 100%, and all patients received stents after RA. Periprocedural major adverse cardiac events occurred in five (2.3%) patients. Postprocedural death was investigated, with a mean follow‐up of 36 months. Mortality amounted to 37.2%. Multivariate analysis revealed that left ventricular ejection fraction < 50%, glomerular filtration rate < 60 ml/min, cardiogenic shock, and diabetes were the only independent mortality predictors. Conclusions We have found that RA and stenting is feasible and viable in an elderly high‐risk population, with exceptional procedural success and acceptable long‐term results. © 2015 Wiley Periodicals, Inc. PMID:26032270
Babunashvili, A M; Navtsishvili, Z G; Konstantinov, B A
2016-02-01
The authors present immediate and long term results of the first in Russia implantation in coronary artery of Palmaz-Shatz metal stent. Indications for stenting were urgent after complicated dissection as a result of balloon dilation of discrete bifurcational stenosis of anterior interventricular artery (IVA). Immediate angiographic and clinical result was good. At control angiography after 13 years their was no restenosis in stented IVA. However novel narrowing was found in left main coronary artery (LMCA) in which drug eluting stent was implanted. Coronary angiography carried out after 7.5 years after stenting of LMCA and in 20 years after stent implantation in IVA revealed good patency of both stented segments without signs of restenosis. This case report demonstrates possibility of long term preservation of angiographic and clinical effect of staged endovascular treatment of coronary atherosclerosis.
Sex differences in the outcomes of stent implantation in mini-swine model.
Kunio, Mie; Wong, Gee; Markham, Peter M; Edelman, Elazer R
2018-01-01
Sex-related differences have been noted in cardiovascular anatomy, pathophysiology, and treatment responses, yet we continued to drive evaluation of vascular device development in animal models without consideration of animal sex. We aimed to understand sex-related differences in the vascular responses to stent implantation by analyzing the pooled data of endovascular interventions in 164 Yucatan mini-swine (87 female, 77 male). Bare metal stents (BMS) or drug-eluting stents (DES) were implanted in 212 coronary arteries (63 single BMS implantation, 68 single DES implantation, 33 overlapped BMS implantation, and 48 overlapped DES implantation). Histomorphological parameters were evaluated from vascular specimens at 3-365 days after stent implantation and evaluated values were compared between female and male groups. While neointima formation at all times after implantation was invariant to sex, statistically significant differences between female and male groups were observed in injury, inflammation, adventitial fibrosis, and neointimal fibrin deposition. These differences were observed independently, i.e., for different procedure types and at different follow-up timings. Only subtle temporal sex-related differences were observed in extent and timing of resolution of inflammation and fibrin clearance. These subtle sex-related differences may be increasingly important as interventional devices meld novel materials that erode and innovations in drug delivery. Erodible materials may act differently if inflammation has a different temporal sequence with sex, and drug distribution after balloon or stent delivery might be different if the fibrin clearance speaks to different modes of pharmacokinetics in male and female swine.
Similarities and differences in coatings for magnesium-based stents and orthopaedic implants
Ma, Jun; Thompson, Marc; Zhao, Nan; Zhu, Donghui
2016-01-01
Magnesium (Mg)-based biodegradable materials are promising candidates for the new generation of implantable medical devices, particularly cardiovascular stents and orthopaedic implants. Mg-based cardiovascular stents represent the most innovative stent technology to date. However, these products still do not fully meet clinical requirements with regards to fast degradation rates, late restenosis, and thrombosis. Thus various surface coatings have been introduced to protect Mg-based stents from rapid corrosion and to improve biocompatibility. Similarly, different coatings have been used for orthopaedic implants, e.g., plates and pins for bone fracture fixation or as an interference screw for tendon-bone or ligament-bone insertion, to improve biocompatibility and corrosion resistance. Metal coatings, nanoporous inorganic coatings and permanent polymers have been proved to enhance corrosion resistance; however, inflammation and foreign body reactions have also been reported. By contrast, biodegradable polymers are more biocompatible in general and are favoured over permanent materials. Drugs are also loaded with biodegradable polymers to improve their performance. The key similarities and differences in coatings for Mg-based stents and orthopaedic implants are summarized. PMID:27695671
iStent as a Solo Procedure for Glaucoma Patients: A Systematic Review and Meta-Analysis.
Malvankar-Mehta, Monali S; Chen, Yufeng Nancy; Iordanous, Yiannis; Wang, Wan Wendy; Costella, John; Hutnik, Cindy M L
2015-01-01
Glaucoma is a leading cause of irreversible blindness. It is firmly entrenched in the traditional treatment paradigm to start with pharmacotherapy. However, pharmacotherapy is not benign and has been well documented to have a number of significant challenges. Minimally invasive glaucoma surgery (MIGS) that targets the outflow pathway with minimal to no scleral dissection has resulted in the need to reconsider the glaucoma treatment paradigm. To perform a systematic review and meta-analysis to evaluate and quantify the effect on post-operative intraocular pressure (IOP) and number of topical glaucoma medications, in patients receiving the iStent MIGS device as the solo procedure without concurrent cataract surgery. A systematic review was conducted by searching various databases between January 1, 2000, and June 30, 2014. Studies reporting up to a maximum follow-up period of 24 months were retrieved and screened using the EPPI-Reviewer 4 gateway. Percentage reduction in IOP (IOPR%), and mean reduction in topical glaucoma medications after surgery were computed. Meta-analysis was performed using STATA v. 13.0. The standardized mean difference (SMD) was calculated as the effect size for continuous scale outcomes. Heterogeneity was determined using the I2 statistics, Z-value, and χ2 statistics. Fixed-effect and random-effect models were developed based on heterogeneity. Sub-group analysis was performed based on the number of iStents implanted and the follow-up period. The outcome measures were changes in the IOP and number of glaucoma medications. The search strategy identified 105 records from published literature and 9 records from the grey literature. Five studies with 248 subjects were included for quantitative synthesis. A 22% IOP reduction (IOPR%) from baseline occurred at 18-months after one iStent implant, 30% at 6-months after two iStents implantations, and 40% at 6-months after implantation of three iStents. A mean reduction of 1.2 bottles per patient of topical glaucoma medications occurred at 18-months after one iStent implant, 1.45 bottles per patient at 6-months after two iStents, and one bottle of medication per patient was reduced at 6-months following placement of three iStents implants. Meta-analysis results showed a significant reduction in the IOP after one iStent (SMD = -1.68, 95% CI: [-2.7, -0.61]), two iStents (SMD = -1.88, 95% CI: [-2.2, -1.56]), and three iStents (SMD = -2, 95% CI: [-2.62, -1.38]) implantation. Results showed a significant drop in the topical glaucoma medications after one iStent (SMD = -2.11, CI: [-3.95, -0.27]), two iStent (SMD = -1.88, CI: [-2.20, -1.56]), and three iStents (SMD = -2.00, CI: [-2.62, -1.38]) implantation. The maximum reduction in IOP occurred at 12-months (SMD = -2.21, CI: [-2.53, -1.88]) and a significant reduction in post-operative topical glaucoma medications occurred even after 18-months of iStent implantation (SMD = -0.71, CI: [-1.15, -0.26]). iStent implantation as a solo procedure without concurrent cataract extraction does lower IOP, and reduces the dependency on glaucoma medications. This effect seems to last at least 18 months.
Chao, Samuel T.; Angermeier, Kenneth; Klein, Eric A.; Reddy, Chandana A.; Ulchaker, James C.; Stephenson, Andrew; Campbell, Steven
2011-01-01
Purpose To study the feasibility/toxicity of urethral stenting with the Memokath® 028SW stent in patients undergoing prostate implant (PI) for prostate adenocarcinoma. Material and methods An Investigational Device Exemption from the Food and Drug Administration (FDA) and institutional review board (IRB) approval were obtained. Twenty patients enrolled. Baseline American Urological Association (AUA) score was obtained prior to PI. Follow-up information was obtained with weekly phone calls for the first 12 weeks and biweekly calls for the next 12 weeks to assess toxicity and AUA score. Removal of the stent was planned at six months after PI, or earlier due to excessive toxicity/patient request. Results Median age was 66.5 years. The median prostate volume was 39 cc (range: 10-90). The median baseline AUA score was 7.5 (range: 1-21). Three patients required intermittent self-catheterization (ISC) within 3 days after PI. No patients required ISC beyond day 3 after PI. The median duration of ISC was 1 day (range: 1-2). AUA scores returned to baseline values 6 weeks after PI. The week 6 AUA score was 10 (range: 4-16). Seven patients (35%) underwent early removal because of patient preference. The reasons were: incontinence (n = 3), discomfort (n = 2), hematuria (n = 1), and obstructive symptoms (n = 1). The median time of stent removal in these patients was 13.9 weeks (range: 0.9-21.4). Thirteen patients (65%) had ISC and/or urinary catheterization post stent removal. Median time for ISC use was 10 days (range: 1-90). Conclusions Urethral stenting with Memokath® in patients undergoing PI was feasible, but resulted in relatively high rate of urinary incontinence and discomfort. Given the adverse effects experienced by patients of this study, further studies should focus only on patients with highest risk of urinary obstruction from PI or those with obstruction needing ISC. PMID:27877196
A novel high nitrogen nickel-free coronary stents system: evaluation in a porcine model.
Zhang, Bin; Chen, Ming; Zheng, Bo; Wang, Xin Gang; Wang, Xi Ting; Fan, Yuan Yuan; Huo, Yong
2014-04-01
To study the safety of the novel high nitrogen nickel-free austenitic stainless steel bare metal stents (BMS) in a recognized porcine coronary model and to select a better grid structure of it. Three types of stents were randomly implanted in different coronary arteries of the same pig: 316 L stainless steel BMS (316 L-BMS) (n=12), novel high nitrogen nickel-free stents Grid A (NF-A-BMS) (n=12) and novel high nitrogen nickel-free stents Grid B (NF-B-BMS) (n=12). In total, eighteen animals underwent successful random placement of 36 oversized stents in the coronary arteries. Coronary angiography was performed after 36 d of stents implantation. Nine animals were respectively sacrificed after 14 d and 36 d for histomorphologic analysis. Quantitative coronary angiography (QCA) showed similar luminal loss (LL) in the three groups: (0.21 ± 0.17) mm for 316 L-BMS, (0.16 ± 0.12) mm for NF-A-BMS, (0.24 ± 0.15) mm for NF-B-BMS (P>0.05). Histomorphomeric analysis after 15 d and 36 d revealed that there was also no significant difference among the three groups in neointimal area (NA) with similar injury scores respectively. High magnification histomorphologic examination showed similar inflammation scores in the three groups, but NF-A-BMS group had poorer endothelialization scores compared with NF-B-BMS group, 2.00 ± 0.63 vs. 2.83 ± 0.41 (P=0.015) at 15 d, which also could be proved by the scanning electron microscope. However, the difference could not been observed at 36 d. The novel NF-BMS showed similar safety as 316 L-BMS during the short-term study. NF-B-BMS had better endothelialization than NF-A-BMS and this may owe to the specific strut units. Copyright © 2014 The Editorial Board of Biomedical and Environmental Sciences. Published by China CDC. All rights reserved.
Torii, Sho; Nakazawa, Gaku; Ijichi, Takeshi; Yoshikawa, Ayako; Ohno, Yohei; Ikari, Yuji
2018-01-01
The aim of this study is to evaluate differences in stent endothelial coverage among the second generation of drug-eluting stents. Incomplete stent coverage is one of the major causes of late stent thrombosis. Rabbits fed a normal diet received an everolimus (Xience Prime; EES) and a zotarolimus-eluting stent (Resolute Integrity; R-ZES) in each iliac artery, followed by sacrifice at 14 and 28 days after stent implantation. In addition, a group of atherosclerotic rabbits similarly received EES and R-ZES, and were sacrificed at 28 days. The extent of stent endothelial coverage was assessed by scanning electron microscopy. To evaluate endothelial coverage after bifurcation stenting, rabbits received EES and R-ZES placed with culotte stenting at the iliac bifurcation, followed by sacrifice at 14 and 28 days. In rabbits fed a normal diet, the percent uncovered strut area 14 days after stent implantation was significantly higher in R-ZES than in EES (10.1% (IQR 9.8-15.5) vs. 3.0% (IQR 1.5-9.7), p = 0.03), whereas it was not significantly different at 28-days (3.9% (IQR 0.8-10.3) vs. 1.0% (IQR 0.0-2.8), p = 0.2). In rabbits with induced atheroma, R-ZES also showed less endothelial coverage 28 days after stent implantation (5.3% (IQR 2.2-9.9) vs. 1.1% (IQR 0-6.2), p = 0.03). In the culotte stenting model, the percent uncovered strut area of the proximal overlapped segment was significantly higher in R-ZES at 14 days (15.8% (IQR 14.3-17.7) vs. 8.8% (IQR 8.3-9.8), p = 0.03) and 28 days (9.9% (IQR 4.1-13.9) vs. 2.5% (IQR 1.6-6.7), p = 0.04) after stent implantation. The carina area also showed a better coverage in EES compared with R-ZES. EES showed a better stent endothelial coverage compared with R-ZES after stent implantation in the early phase in normals, in arteries with lipid rich plaque, and in bifurcation stented sites.
Terra, Ricardo Mingarini; Minamoto, Helio; Tedde, Miguel Lia; Almeida, José Luiz Jesus de; Jatene, Fabio Biscegli
2007-01-01
To evaluate the Polyflex stent in terms of its efficacy, ease of implantation, and complications in patients with tracheobronchial affections. This was a prospective study, in which sixteen patients with inoperable tracheal stenosis secondary to orotracheal intubation (n = 12), neoplasia (n = 3), or Wegener's granulomatosis (n = 1) were monitored. Of these patients, eleven were women, and five were men. The mean age was 42.8 years (range, 21-72 years). Patients were submitted to implantation of a total of 21 Polyflex stents. All procedures were carried out in the operating room under general anesthesia, and the stents were implanted via suspension laryngoscopy using the stent applicator. Stents were implanted and symptoms were resolved in all cases. The stents remained in place for a mean period of 7.45 months, ranging from 2 to 18 months. The complications observed in the immediate postoperative period were dysphonia (in two patients, 12.5%) and odynophagia (in two patients, 12.5%). Late complications were cough (in ten patients, 62.5%), migration (in seven patients, 43.75%), granuloma formation (in two patients, 12.5%), and pneumonia (in one patient, 6.25%). The Polyflex stent is easily implanted, easily removed, well tolerated by patients and effective in resolving symptoms. However, its use is associated with a high rate of migration, especially in patients with post-orotracheal intubation stenosis.
The trabecular bypass stent in a pseudophakic glaucoma patient: A 1-year follow-up
Fea, Antonio M; Dogliani, Monica; Machetta, Federica; Lale-Lacroix, Gabriella; Brogliatti, Beatrice; Grignolo, Federico M
2008-01-01
Purpose To describe the 1-year success of a trabecular stent implant in a pseudophakic glaucoma patient. The stent is implanted through a small corneal incision under gonioscopic control. Intraocular pressure control was reported in cultured human anterior segment. Design Observational case report. Methods We report the case of a patient who was implanted and followed-up for 1 year at the Dipartimento di Fisiopatologia Clinica. The main outcome measures were intraocular pressure and visual field. Results The patient’s intraocular pressure was controlled with topical beta-blockers for 6 months and without therapy for 6 months. Two diurnal curves demonstrated achievement of target pressure during the day. The 1-year visual field was unchanged. Conclusions We are not aware of previous reports of trabecular stent implantation in pseudophakic patients. The trabecular stent had minimal peri-operative morbidity. Identification of the implantation site is challenging and reduction of efficacy over time may occur. PMID:19668446
Miłek, Tomasz; Ciostek, Piotr
2015-07-01
Colorectal cancer is the second leading cause of death due to cancer in Poland. The traditional approach to treat patients included a surgical procedure. Irrespective of the surgical method being used, surgical treatment of malignant colorectal obstruction is associated with prolonged hospitalisation, and the postoperative mortality rate is approximately 5-11%. Due to these problems, more interest has been shown in less invasive methods. Prosthesis implantation is a leading endoscopic method used currently in palliative or preoperative treatment. To compare the results of implantation of traditional stents with the results of implantation of an own stent using minimally invasive methods. Left-sided colon obstruction due to cancer was an indication for transplantation. All patients were aged over 70 years and had serious concomitant diseases. The control group included 50 patients with colorectal cancer who received traditional stents in the period 2009-2011. Our stent covers only the internal length of a tumour. It is not equipped with anti-migration flares. To minimize the risk of migration it has a system of hooks that are responsible for permanent anchorage of the stent within the tumour mass. Implantation technical and clinical success defined as effective decompression of intestinal obstruction was 100% in both groups. There were 2 cases of stent migration in the control group. It is possible to achieve a secure surgical anastomosis after intestinal decompression. Stent implantation is fast and safe thanks to the positioning system that was used. The use of labelled hooks is a secure anti-migration solution.
Jenny, D B; Robert, G P; Fajadet, J C; Cassagneau, B G; Marco, J
1992-04-01
In this brief report we describe a case of successful multivessel PTCA with intracoronary stent implantation using a new large-lumen 7F catheter from the left brachial approach. The application of this technique should be considered for intravascular stent implantation when anticoagulation ideally should not be interrupted or in anatomical situations limiting femoral vascular access.
A simple three-dimensional stent for proper placement of mini-implant
2013-01-01
Background This paper deals with the fabrication of a three-dimensional stent which is simple in design but provides an accurate placement of a mini-implant in three planes of space, namely, sagittal (root proximity), vertical (attached gingiva/alveolar mucosa) and transverse (angulation). Findings The stent is made of 0.018 × 0.025 in. stainless steel archwire which consists of a ‘u loop’ angulated at 20°, a vertical limb, a horizontal limb and a stop. The angulation of the ‘u’ helps in the placement of the mini-implant at 70° to the long axis of the tooth. The vertical height is determined such that the mini-implant is placed at the mucogingival junction. The mini-implant is placed with the aid of the stent, and its angulation and proximity to the adjacent roots are checked with a cone beam computed tomography image. The cone beam computed tomography image showed the mini-implant at an angle of 70° to the long axis of the tooth. There is no contact between mini-implant and the roots of the adjacent teeth. Conclusion This stent is simple, easy to fabricate, cost-effective, and provides ease of insertion/removal, and three-dimensional orientation of the mini-implant. PMID:24326158
Nitinol Esophageal Stents: New Designs and Clinical Indications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Strecker, Ernst-Peter; Boos, Irene; Vetter, Sylvia
1996-11-15
Purpose: To evaluate the clinical use of covered and noncovered, knitted nitinol stents in patients presenting new stent indications. Methods: Self-expandable, knitted nitinol stents were implanted in four patients for treatment of dysphagia. In two patients who had malignant strictures and had esophago-respiratory fistulae and in one patient with an esophagocutaneous fistula, polytetrafluoroethylene (PTFE)-covered stents were implanted. One patient received a noncovered stent, but a retrograde approach through a percutaneous endoscopic gastrostomy (PEG) fistula had to be chosen for recanalization of an esophageal occlusion. Two patients received stents for treatment of benign strictures. Results: Recanalization of the stricture and stentmore » implantation were performed under fluoroscopic control without any procedure-related morbidity or mortality. Dysphagia improved in all patients and the esophageal fistulae could be sealed off by covered stents. During a maximum follow-up of 18 months, there was no stent migration or esophageal perforation. Complications observed were stent stenosis due to food impaction (1/4) and benign stent stenosis (2/2). Most complications could be treated by the interventional radiologist. Conclusion: Self-expandable, covered Nitinol stents provide an option for the treatment of dysphagia combined with esophageal fistulae. In combination with interventional radiology techniques, even complex strictures are accessible. For benign strictures, the value of stent treatment has not yet been proven.« less
Kang, Jeehoon; Cho, Young-Seok; Kim, Seong-Wook; Park, Jin Joo; Yoon, Yeonyee E; Oh, Il-Young; Yoon, Chang-Hwan; Suh, Jung-Won; Youn, Tae-Jin; Chae, In-Ho; Choi, Dong-Ju
2015-01-01
Despite the benefits of successful percutaneous coronary interventions (PCIs) for chronic total occlusion (CTO) lesions, PCIs of CTO lesions still carry a high rate of adverse events, including in-stent restenosis (ISR). Because previous reports have not specifically investigated the intravascular ultrasound (IVUS) predictors of ISR in CTO lesions, we focused on these predictors. We included 126 patients who underwent successful PCIs, using drug-eluting stents, and post-PCI IVUS of CTO lesions. Patient and lesion characteristics were analyzed to elucidate the ISR predictors. In each lesion, an average of 1.7 ± 0.7 (mean length, 46.4 ± 20.3 mm) stents were used. At 9 months follow-up, 14 (11%) patients demonstrated ISR, and 8 (6.3%) underwent target lesion revascularization. Multivariate logistic regression analysis showed that the independent predictors of ISR were the post-PCI minimal luminal diameter (MLD) and the stent expansion ratio (SER; minimal stent cross-sectional area (CSA) over the nominal CSA of the implanted stent), measured using quantitative coronary angiography (QCA) and IVUS, respectively. A receiver operating characteristic analysis indicated that the best post-PCI MLD and SER cut-off values for predicting ISR were 2.4 mm (area under the curve [AUC], 0.762; 95% confidence interval (CI), 0.639-0.885) and 70% (AUC, 0.714; 95% CI, 0.577-0.852), respectively. Lesions with post-PCI MLD and SER values less than these threshold values were at a higher risk of ISR, with an odds ratio of 23.3 (95% CI, 2.74-198.08), compared with lesions having larger MLD and SER values. Thus, the potential predictors of ISR, after PCI of CTO lesions, are the post-PCI MLD and SER values. The ISR rate was highest in lesions with a post-PCI MLD ≤2.4 mm and an SER ≤70%.
Holzer, Ralf; Qureshi, Shakeel; Ghasemi, Abdolrahim; Vincent, Julie; Sievert, Horst; Gruenstein, Daniel; Weber, Howard; Alday, Luis; Peirone, Alejandro; Zellers, Thomas; Cheatham, John; Slack, Michael; Rome, Jonathan
2010-10-01
Since the 1980s, stent implantation has evolved as an important therapeutic strategy for coarctation of the aorta. However, available data is frequently flawed by short follow-up, lack of adequate follow-up imaging, and retrospective nature of data collection. Data was prospectively collected using a multicenter registry congenital cardiovascular interventional study consortium (CCISC). Between 2000 and 2009, 302 patients from 34 centers with a median weight of 58 kg underwent stent implantation for coarctation. Eligible patients (44%) completed intermediate follow-up (3-18 months) with integrated imaging (cath, CT, MRI), whereas 21% completed long-term follow-up (>18-60 months). Procedural success was defined as UL/LL systolic gradient of less than 20 mm Hg, lack of significant recurrent obstruction, and freedom from unplanned repeat intervention. Acute procedural success was 96%. Cumulative intermediate success was 86%, and cumulative long-term success was 77%. Unplanned repeat interventions were required in 4%, and aortic wall complications were seen in 1% of patients (dissection n = 1 and aneurysm n = 3). Other adverse events (n = 15) occurred mainly acutely and included technical complications such as stent malposition (n = 9). At long-term follow-up, 23% of patients continued to have systolic blood pressure above the 95th centile, 9% had an upper-to-lower limb blood pressure gradient in excess of 20 mm Hg, and 32% were taking antihypertensive medication. This study documented acute, intermediate, and long-term outcome data comparable or superior with other surgical or interventional series. However, even with successful initial stent therapy, patients continue to require long-term follow-up and have associated long-term morbidity, relating to aortic wall complications, systemic hypertension, recurrent obstruction as well as need for repeat intervention. © 2010 Wiley-Liss, Inc.
Kang, Woong Chol; Shin, Eak Kyun; Park, Chul-Hyun; Kang, Jin Mo; Ko, Young-Guk; Choi, Donghoon; Youn, Young Nam; Shim, Won-Heum
2013-08-01
To evaluate the outcomes of hybrid endovascular repair for aortic arch pathology. This study was a retrospective analysis involving patients who underwent hybrid endovascular repair for aortic arch pathologies. Twenty-one patients (16 men; mean age, 64.7 ± 16.2 years) with aortic arch pathologies were treated by hybrid endovascular repair. The indications for treatment included increased aneurysm size in 16 cases (71.4%), rupture or impending aneurysmal rupture in 5 cases (23.8%), and rapid growth of aortic dissection (≥ 10 mm/y) in 1 case (4.8%). Supra-aortic vessel transposition and stent-graft implantation were achieved in all cases. Two types of stent-graft was used, as follows: the Seal thoracic stent-graft in 14 patients (66.7%); and the Valiant stent grafts in 7 patients (33.3%). Perioperative complications affected 5 patients (23.8%), as follows: bleeding (n = 4, 19.0%); stroke (n = 3, 14.3%); renal failure (n = 2, 9.5%); vascular injury (n = 1, 4.8%), and respiratory failure (n = 1, 4.8%). Two patients died within 30 days (9.5%). Technical success was achieved in 15 patients (71.5%). Early endoleaks were noted in 4 patients (19.0%). One patient died during follow-up (mean, 21.3 ± 11.6 months) due to a de novo intramural hematoma. Persistent early endoleaks were noted in 4 patients (19.0%); 2 of the 4 patients were successfully managed with implantation of additional stent-grafts. No late onset endoleaks were noted. The death-free survival and reintervention-free survival rates during follow-up were 85.7% and 90.5%, respectively. Hybrid treatment with supra-aortic vessel transposition and endovascular repair may be an option in frail patients in who open procedures is too risky. © 2013 Wiley Periodicals, Inc.
Ohlow, Marc-Alexander; von Korn, Hubertus; Gunkel, Oliver; Farah, Ahmed; Fuhrmann, Joerg T; Lauer, Bernward
2014-12-01
Drug-eluting stents (DES) constitute a major achievement in preventing re-stenosis, concerns remain regarding the increased inflammatory responses associated with the polymers used. This analysis focuses on outcomes in patients receiving the polymer-free sirolimus-eluting stent system YUKON-Choice (Yukon-DES, Translumina, Germany). From 01/2006-09/2008 all patients receiving Yukon-DES (≥2.5 mm diameter) were prospectively enrolled in our registry. The primary endpoint was long-term major adverse cardiac events (MACE). 701 patients were included in our registry. Mean age was 65.7 ± 10 years (73% male gender, 35.5% diabetes, and 32.2% acute coronary syndrome). 76% of the lesions were of Type B2/C. Lesion length was 24.6 ± 5.2 mm and mean stent diameter was 2.8 ± 0.4 mm. A total of 511 pts (72%) underwent 6-months angiographic follow-up, target vessel revascularization was noted in 23.5%. At 5 years clinical outcomes were: cardiac death 5.8%; myocardial infarction 3.4%; and TVR 24.6%. The incidence of MACE differed significantly between "on-label" and "off-label" indications (14.8% vs. 40.8% MACE; P < 0.001). Incidence of definitive/probable stent thrombosis (ST) was 1.14% (8/701); very late (>1 year) ST occurred in 0.29%. Our data suggests that the implantation of the sirolimus-coated polymer-free YUKON-DES is safe and feasible with a very low incidence of ST in this real world patient cohort with high percentage of diabetes and small vessels. © 2013 Wiley Periodicals, Inc.
van den Brand, Marcel J B M; Rensing, Benno J W M; Morel, Marie-angèle M; Foley, David P; de Valk, Vincent; Breeman, Arno; Suryapranata, Harry; Haalebos, Maximiliaan M P; Wijns, William; Wellens, Francis; Balcon, Rafael; Magee, Patrick; Ribeiro, Expedito; Buffolo, Enio; Unger, Felix; Serruys, Patrick W
2002-02-20
We sought to assess the relationship between completeness of revascularization and adverse events at one year in the ARTS (Arterial Revascularization Therapies Study) trial. There is uncertainty to what extent degree of completeness of revascularization, using up-to-date techniques, influences medium-term outcome. After consensus between surgeon and cardiologist regarding the potential for equivalence in the completeness of revascularization, 1,205 patients with multivessel disease were randomly assigned to either bypass surgery or stent implantation. All baseline and procedural angiograms and surgical case-record forms were centrally assessed for completeness of revascularization. Of 1,205 patients randomized, 1,172 underwent the assigned treatment. Complete data for review were available in 1,143 patients (97.5%). Complete revascularization was achieved in 84.1% of the surgically treated patients and 70.5% of the angioplasty patients (p < 0.001). After one year, the stented angioplasty patients with incomplete revascularization showed a significantly lower event-free survival than stented patients with complete revascularization (i.e., freedom from death, myocardial infarction, cerebrovascular accident and repeat revascularization) (69.4% vs. 76.6%; p < 0.05). This difference was due to a higher incidence of subsequent bypass procedures (10.0% vs. 2.0%; p < 0.05). Conversely, at one year, bypass surgery patients with incomplete revascularization showed only a marginally lower event-free survival rate than those with complete revascularization (87.8% vs. 89.9%). Complete revascularization was more frequently accomplished by bypass surgery than by stent implantation. One year after bypass, there was no significant difference in event-free survival between surgically treated patients with complete revascularization and those with incomplete revascularization, but patients randomized to stenting with incomplete revascularization had a greater need for subsequent bypass surgery.
De Servi, Stefano; Morici, Nuccia; Boschetti, Enrico; Rossini, Roberta; Martina, Paola; Musumeci, Giuseppe; D'Urbano, Maurizio; Lazzari, Ludovico; La Vecchia, Carlo; Senni, Michele; Klugmann, Silvio; Savonitto, Stefano
2016-05-01
Intravenous administration of a short acting glycoprotein IIb/IIIa inhibitor has been proposed as a bridge to surgery in patients on dual antiplatelet treatment, but data in comparison with other treatment options are not available. We conducted a retrospective analysis of consecutive patients who underwent un-deferrable, non-emergency surgery after coronary stenting. The bridge therapy was performed after discontinuation of the oral P2Y12 inhibitor by using i.v. tirofiban infusion. Net Adverse Clinical Events (NACE) was the primary outcome. We analyzed 314 consecutive patients: the bridge strategy was performed in 87 patients, whereas 227 were treated with other treatment options and represent the control group. Thirty-day NACE occurred in 8% of patients in the bridge group and in 22.5% in the control group (p < 0.01). Bridge therapy was associated with decreased 30-day NACE rate [Odds ratio (OR) 0.30; 95% confidence interval (CI) 0.13-0.39; p < 0.01], particularly when the time interval between stenting and surgery was ≤ 60 days (OR 0.09, 95% CI 0.01-0.72; p = 0.02). There were no cases of stent thrombosis in the bridge group and 3 (1.3%) in the control group. Bridge therapy was associated with decreased events rates as compared to both patients with and without P2Y12 inhibitors discontinuation in the control group. After adjustment for the most relevant covariates, the favorable effect of the bridge therapy was not materially modified. In conclusion, perioperative bridge therapy using tirofiban was associated with reduced 30-day NACE rate, particularly when surgery was performed within 60 days after stent implantation.
Wang, Tao; Liu, Sheng; Zheng, Yan-Bo; Song, Xue-Peng; Sun, Bo-Lin; Jiang, Wen-Jin; Wang, Li-Gang
2017-08-01
Aim: To study the feasibility and curative effect of 125 I seeds articles combined with biliary stent implantation in the treatment of malignant obstructive jaundice. Patients and Methods: Fifty patients with malignant obstructive jaundice were included. Twenty-four were treated by biliary stent implantation combined with intraluminal brachytherapy by 125 I seeds articles as the experimental group, while the remaining 26 were treated by biliary stent implantation only as the control group. The goal of this study was to evaluate total bilirubin, direct bilirubin and tumor markers (cancer antigen (CA)-199, CA-242 and carcinoembryonic antigen (CEA)), as well as biliary stent patency status and survival time before and after surgery. Results: Jaundice improved greatly in both groups. The decreases of CA-199 and CA-242 had statistical significance (p=0.003 and p=0.004) in the experimental group. The ratio of biliary stent patency was 83.3% (20/24) in the experimental group and 57.7% (15/26) in the control group (p=0.048). The biliary stent patency time in the experimental group was 1~15.5 (mean=9.84) months. The biliary stent patency time in the control group was 0.8~9 (mean=5.57) months, which was statistically significant (p=0.018). The median survival time was 10.2 months in the experimental group, while 5.4 months in control group (p<0.05). Conclusion: 125 I seeds articles combined with biliary stent implantation significantly prolongs biliary stent patency time and survival time for patients with malignant obstructive jaundice possibly by inhibiting the proliferation of vascular endothelial cells and the growth of tumor. Copyright© 2017, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.
Shin, Jung-Hoon; Park, Seong-Ho; Kim, Chang-Hyun; Lee, Chang-Young
2014-10-01
Stent thrombosis is a major limitation of stent-assisted coiling, which is an effective method for treating wide-necked aneurysms. Although early in-stent thrombosis has been reported, very late stent thrombosis (VLST) (>1 year) has not been reported following implantation of a single self-expandable stent designed for coiling. Herein, the authors present a case of VLST that occurred 14 months after single stent implantation in a large paraclinoid aneurysm with an ultra-wide neck involving the parent artery circumferentially. This case indicates the need for establishing guidelines regarding the optimal duration of prophylactic antiplatelet therapy following stent-assisted coiling, which remains undefined in the neuroendovascular field.
Sabbah, Mahmoud; Kadota, Kazushige; El-Eraky, Azza; Kamal, Hanan M; Abdellah, Ahmed-Tageldien; El Hawary, Ahmed
2017-06-01
Differences in stent platform, polymer coatings, and antirestenotic drugs among the current in use second-generation drug-eluting stents (G2-DESs) may induce significant variations in neointimal response and vascular healing, which may impact the prevalence of neoatherosclerosis (NA) and morphological appearance of the restenotic tissue. Utilizing Optical frequency domain imaging, two independent reviewers, retrospectively compared the prevalence of neoatherosclerosis (NA), and the morphological differences, and tissue characteristics of 50 G2-DESs in-stent restenosis (ISR) lesions (35 everolimus-eluting stent [22 cobalt-chromium (CoCr), 13 platinum-chromium (PtCr)], and 15 biolimus-eluting stent [BES]) implanted liberally in unrestricted coronary lesions. More than half of the stents were implanted in type C lesions, while 40% of the stents were implanted primarily in lesions with recanalized chronic total occlusion. NA, defined as a neointima formation with the presence of lipids or calcification, was observed in fewer than half (24/50) of all ISR lesions with no significant in-between group differences (41%, 69%, and 40% in CoCr, PtCr, and BES respectively, P = 0.22), nor were there any significant differences in the morphological appearance or tissue characteristics between all G2-DESs subtypes. Acknowledging some limitations, our results may suggest that the prevalence of NA and the morphological appearance of restenotic lesions might not differ when G2-DESs are implanted in unrestricted, rather complex, coronary lesions. © 2017, Wiley Periodicals, Inc.
Ishihara, Takayuki; Awata, Masaki; Iida, Osamu; Fujita, Masashi; Masuda, Masaharu; Okamoto, Shin; Nanto, Kiyonori; Kanda, Takashi; Tsujimura, Takuya; Uematsu, Masaaki; Mano, Toshiaki
2018-01-15
The ultrathin strut biodegradable polymer sirolimus-eluting stent (Orsiro, O-SES) exhibits satisfactory clinical outcomes. However, no report to date has documented the intravascular status of artery repair after O-SES implantation. We examined 5 O-SES placed in 4 patients (age 65 ± 12 years, male 75%) presenting with stable angina pectoris due to de novo lesions in native coronary arteries. Coronary angioscopy was performed immediately after percutaneous coronary intervention and 1 year later. Angioscopic images were analyzed to determine the following: (1) dominant grade of neointimal coverage (NIC) over the stent; (2) maximum yellow plaque grade; and (3) existence of thrombus. Yellow plaque grade was evaluated both immediately after stent implantation and at the time of follow-up observation. The other parameters were evaluated at the time of follow-up examination. NIC was graded as: grade 0, stent struts exposed; grade 1, struts bulging into the lumen, although covered; grade 2, struts embedded in the neointima, but translucent; grade 3, struts fully embedded and invisible. Yellow plaque severity was graded as: grade 0, white; grade 1, light yellow; grade 2, yellow; and grade 3, intensive yellow. Angioscopic findings at 1 year demonstrated the following: dominant NIC grade 1, grade 2, and grade 3 in 1, 2, and 2 stents, respectively; all stents were covered to some extent; focal thrombus adhesion was observed in only 1 stent. Yellow plaque grade did not change from immediately after stent implantation to follow-up. O-SES demonstrated satisfactory arterial repair 1 year after implantation.
[Expandable metal mesh stents for treatment of tracheal stenoses and tracheomalacia].
Müller, C; Dienemann, H; Hoffmann, H; Berger, H; Storck, M; Jolk, A; Schildberg, F W
1993-01-01
The treatment of tracheo-bronchial stenosis or tracheomalacia is mainly carried out by means of resection or tracheoplastic operative strategies. Since the introduction of metal-mesh stents, a definitive endoluminal therapy has to be considered under new aspects. Six patients with malignant stenosis or tracheomalacia due to compression were treated by implantation of Palmaz- or Wallstents. Immediately after the implantation, patients were relieved from dyspnoea, the forced inspiratory volume-1 (FIV1) was normalized. All implanted stents were well tolerated, even in the long-time follow-up (19 months). Bronchoscopic control showed overgrowth of the metal meshes by respiratory epithelium. The implantation of metal-mesh stents is an adequate alternative in the treatment of malignant stenosis and tracheomalacia.
Moreira, Ricardo; Velz, Thaddaeus; Alves, Nuno; Gesche, Valentine N.; Malischewski, Axel; Schmitz-Rode, Thomas; Frese, Julia
2015-01-01
Transcatheter aortic valve implantation of (nonviable) bioprosthetic valves has been proven a valid alternative to conventional surgical implantation in patients at high or prohibitive mortality risk. In this study we present the in vitro proof-of-principle of a newly developed tissue-engineered heart valve for minimally invasive implantation, with the ultimate aim of adding the unique advantages of a living tissue with regeneration capabilities to the continuously developing transcatheter technologies. The tube-in-stent is a fibrin-based tissue-engineered valve with a tubular leaflet design. It consists of a tubular construct sewn into a self-expandable nitinol stent at three commissural attachment points and along a circumferential line so that it forms three coaptating leaflets by collapsing under diastolic back pressure. The tubular constructs were molded with fibrin and human umbilical vein cells. After 3 weeks of conditioning in a bioreactor, the valves were fully functional with unobstructed opening (systolic phase) and complete closure (diastolic phase). Tissue analysis showed a homogeneous cell distribution throughout the valve's thickness and deposition of collagen types I and III oriented along the longitudinal direction. Immunohistochemical staining against CD31 and scanning electron microscopy revealed a confluent endothelial cell layer on the surface of the valves. After harvesting, the valves underwent crimping for 20 min to simulate the catheter-based delivery. This procedure did not affect the valvular functionality in terms of orifice area during systole and complete closure during diastole. No influence on the extracellular matrix organization, as assessed by immunohistochemistry, nor on the mechanical properties was observed. These results show the potential of combining tissue engineering and minimally invasive implantation technology to obtain a living heart valve with a simple and robust tubular design for transcatheter delivery. The effect of the in vivo remodeling on the functionality of the tube-in-stent valve remains to be tested. PMID:25380414
Lu, Qi; Ye, Fang; Yang, Xiangjun; Gu, Qingqing; Wang, Peng; Zhu, Jianhua; Shen, Li; Gong, Feirong
2015-01-01
Curcumin was reported to exhibit a wide range of pharmacological effects including antioxidant, anti-inflammatory, and antiproliferative activities and significantly prevent smooth muscle cells migration. In the present study, a novel kind of curcumin loaded nanoparticles (Cur-NP) has been prepared and characterized with the aim of inhibiting inflammation formation and accelerating the healing process of the stented arteries. Cur-NP was administrated intravenously after stent implantation twice a week and detailed tissue responses were evaluated. The results demonstrated that intravenous administration of Cur-NP after stent implantation accelerated endothelial cells restoration and endothelium function recovery and may potentially be an effective therapeutic alternative to reduce adverse events for currently available drug eluting stents.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zelenak, Kamil, E-mail: zelenak@unm.sk; Zelenakova, Jana; DeRiggo, Julius
2011-12-15
Endovascular treatment for a wide-neck anterior communicating artery (AcomA) aneurysm remains technically challenging. Stent-assisted embolization has been proposed as an alternative of treatment of complex aneurysms. The X-configuration double-stent-assisted technique was used to achieve successful coiling of wide-neck AcomA aneurysm. Implanted stent can alter intra-arterial flow. Follow-up angiograms 4 months later showed flow changes due to used X-technique of stents implantation and filling of the anterior cerebral artery from the opposite internal carotid artery.
Novel self-expandable, stent-based transcatheter pulmonic valve: a preclinical animal study.
Kim, Gi Beom; Lim, Hong-Gook; Kim, Yong Jin; Choi, Eun Young; Kwon, Bo Sang; Jeong, Saeromi
2014-04-15
Because transcatheter implantation of pulmonary valve is indicated for limited-size dysfunctional right ventricular outflow tract only as a balloon-expandable stent, we investigated the feasibility of a large-diameter self-expandable valved stent and the durability of the valve after >6 months. We made a nitinol-wire-based, self-expandable valved stent with leaflets made from porcine pericardium. The porcine pericardium was treated with α-galactosidase, glutaraldehyde, and glycine after decellularization. After cutting the inguinal or cervical area, we implanted a valved stent in 12 sheep through the femoral or jugular vein by using an 18-Fr delivery catheter, controlling the catheter handles and hook block under fluoroscopic and echocardiographic guidance. The mean body weight of sheep was 43.9 kg. We successfully implanted valved stents (diameter: 24 mm in 7 sheep, 26 mm in 5 sheep) in good position in 8 sheep, in the main pulmonary artery (PA) in 2 sheep, and in the right ventricular outlet tract (RVOT) in 2 sheep. We sacrificed 8 sheep (6 sheep in good position, 1 sheep in the main PA, and 1 sheep in the RVOT) after >6 months. Five of the 6 sheep implanted in good position showed well-preserved valve morphology at the time of sacrifice. Histologic findings after routine sacrifice showed well-maintained collagen wave structure and no visible calcification in all explanted valve leaflets. Transcatheter implantation of a nitinol-wire-based, self-expandable valved stent in the pulmonic valve was feasible, and stents implanted in good position showed well-preserved valve leaflets with functional competence in the mid-term results. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Li, W; Zhai, S; Xu, K; Li, Q; Zhong, H; Li, T; Zhang, Z
2018-06-01
The aim was to evaluate the feasibility and safety of a new unibody branched stent graft for the reconstruction of the canine aortic arch. The unibody branched stent grafts included single branched stent grafts and double branched stent grafts. The main stent graft and branched limbs were sutured together. The branched stent grafts were folded into the introducer system, which consisted of a double channel catheter, a detachable sleeve, and an introducer sheath. The branched stent grafts were introduced and deployed into the aortic arch by the delivery system. Twenty adult mongrel dogs were used for the experiments. Ten dogs were implanted with single branched stent grafts; the other 10 were implanted with double branched stent grafts. The surviving animals were followed up for 3 months. Computed tomography angiography (CTA) was performed to observe the status of the branched stent grafts. All the unibody branched stent grafts were successfully implanted into the canine aortic arches. The technical success rate was 100%. There was no cerebral infarction, paraplegia or incision infection. CTA showed that all the branched stent grafts were patent; there was no endoleak or stent migration. The unibody branched stent graft system could be used to reconstruct the aortic arch. The animal experimental procedures demonstrated the safety and feasibility of the unibody branched stent graft system. Copyright © 2018 European Society for Vascular Surgery. Published by Elsevier B.V. All rights reserved.
Trépanier, C; Leung, T K; Tabrizian, M; Yahia, L H; Bienvenu, J G; Tanguay, J F; Piron, D L; Bilodeau, L
1999-01-01
Nickel-titanium (NiTi) offers many advantages for the fabrication of coronary stents: shape memory, superelasticity, and radiopacity. However, many authors highlighted the selective dissolution of Ni from the alloy during the corrosion process that could lead to potential toxicity. The improvement of the NiTi stent's corrosion resistance by different surface treatments (electropolishing, heat treatment, and nitric acid passivation) was reported in a previous article. In the present study a comparative biocompatibility evaluation of such stents was performed through in vitro and in vivo assays. A cell proliferation test was completed to evaluate the cytotoxicity of surface treated NiTi using human fibroblasts. Then a stent implantation was performed in rabbit paramuscular muscle to study the inflammatory response generated by the same implants. Cell proliferation tests generally indicated an in vitro biocompatibility of our samples similar to the control group. An in vivo implantation study demonstrated the gradual overall reduction with time of the fibrocellular capsule thickness surrounding the implants. After a 12-week implantation period, the fibrous capsules surrounding the different implants tended toward the same value of 0.07 mm, which suggested that all surface treatments produced a similar biological response. This low value of the fibrocellular capsule indicated that our NiTi surface treated implants were relatively inert.
Chandwani, Prakash; Prajapati, Jayesh; Porwal, Sanjay; Khambhati, Bhavesh; Thakkar, Ashok
2015-02-01
Coronary artery disease is the most common catastrophic disease in India. The safety and effectiveness of dual vessel sirolimus-eluting stent (SES) implantation (used as an intervention in CAD) is currently unknown in Indian population. The purpose of this study was to investigate one year clinical outcomes of patients with dual vessel coronary artery disease after implantation of the Supralimus-Core SES, in a "real-world" setting. We evaluated 60 patients between April-2011 and August-2012, who underwent dual vessel percutaneous coronary intervention (PCI) with the Supralimus-Core SES implantation at the same index procedure. Dual vessels were defined as involvement of two major epicardial vessels (right, left anterior descending, circumflex, or left main coronary arteries) or one major epicardial vessel and a branch (≥2.5 mm in diameter) originating from another major epicardial vessel. The primary endpoint was target lesion failure (TLF) defined as the composite of cardiac death, myocardial infarction (MI), and clinically-driven target lesion revascularization (TLR) at one year. Secondary endpoint included combined (definite, probable and possible) stent thrombosis (ST). A total of 120 lesions were treated in 60 enrolled patients (mean age 56.0±9.2 y; 80.0% male) with average stent length of 23.1±8.5 mm. Among 60 patients, diabetes, hypertension and hypercholesterolemia were present in 15 (25.0%), 22 (36.7%) and 25 (41.7%) patients respectively. Indications for PCI were unstable angina in 30 (50.0%) patients and stable angina in 11 (18.3%) patients. Overall, 40 (33.3%) lesions were classified as complex (American College of Cardiology/American Heart Association type B2/C). The cumulative TLF rate was 5.0% (n=3) at one year. Cardiac death, MI and clinically-driven TLR occurred in 1 (1.7%), 0 (0%) and 2 (3.3%) patients, respectively at one year follow-up. The Kaplan-Meier curve of the freedom from overall events at one year was 95.0%. According to the Academic Research Consortium definition, there were no events of stent thrombosis during one year. Our study shows that, dual vessel Supralimus-Core SES implantation allows safe and effective treatment with low rates of TLF at one year follow-up in Indian population.
Kadziela, Jacek; Michalowska, Ilona; Pregowski, Jerzy; Janaszek-Sitkowska, Hanna; Lech, Katarzyna; Kabat, Marek; Staruch, Adam; Januszewicz, Andrzej; Witkowski, Adam
2016-01-01
Randomized trials comparing invasive treatment of renal artery stenosis with standard pharmacotherapy did not show substantial benefit from revascularization. One of the potential reasons for that may be suboptimal procedure technique. To compare renal stent sizing using two modalities: three-dimensional renal computed tomography angiography (CTA) versus conventional angiography. Forty patients (41 renal arteries), aged 65.1 ±8.5 years, who underwent renal artery stenting with preprocedural CTA performed within 6 months, were retrospectively analyzed. In CTA analysis, reference diameter (CTA-D) and lesion length (CTA_LL) were measured and proposed stent diameter and length were recorded. Similarly, angiographic reference diameter (ANGIO_D) and lesion length (ANGIO_LL) as well as proposed stent dimensions were obtained by visual estimation. The median CTA_D was 0.5 mm larger than the median ANGIO_D (p < 0.001). Also, the proposed stent diameter in CTA evaluation was 0.5 mm larger than that in angiography (p < 0.0001). The median CTA_LL was 1 mm longer than the ANGIO_LL (p = NS), with significant correlation of these variables (r = 0.66, p < 0.0001). The median proposed stent length with CTA was equal to that proposed with angiography. The median diameter of the implanted stent was 0.5 mm smaller than that proposed in CTA (p < 0.0005) and identical to that proposed in angiography. The median length of the actual stent was longer than that proposed in angiography (p = 0.0001). Renal CTA has potential advantages as a tool adjunctive to angiography in appropriate stent sizing. Careful evaluation of the available CTA scans may be beneficial and should be considered prior to the planned procedure.
Michalowska, Ilona; Pregowski, Jerzy; Janaszek-Sitkowska, Hanna; Lech, Katarzyna; Kabat, Marek; Staruch, Adam; Januszewicz, Andrzej; Witkowski, Adam
2016-01-01
Introduction Randomized trials comparing invasive treatment of renal artery stenosis with standard pharmacotherapy did not show substantial benefit from revascularization. One of the potential reasons for that may be suboptimal procedure technique. Aim To compare renal stent sizing using two modalities: three-dimensional renal computed tomography angiography (CTA) versus conventional angiography. Material and methods Forty patients (41 renal arteries), aged 65.1 ±8.5 years, who underwent renal artery stenting with preprocedural CTA performed within 6 months, were retrospectively analyzed. In CTA analysis, reference diameter (CTA-D) and lesion length (CTA_LL) were measured and proposed stent diameter and length were recorded. Similarly, angiographic reference diameter (ANGIO_D) and lesion length (ANGIO_LL) as well as proposed stent dimensions were obtained by visual estimation. Results The median CTA_D was 0.5 mm larger than the median ANGIO_D (p < 0.001). Also, the proposed stent diameter in CTA evaluation was 0.5 mm larger than that in angiography (p < 0.0001). The median CTA_LL was 1 mm longer than the ANGIO_LL (p = NS), with significant correlation of these variables (r = 0.66, p < 0.0001). The median proposed stent length with CTA was equal to that proposed with angiography. The median diameter of the implanted stent was 0.5 mm smaller than that proposed in CTA (p < 0.0005) and identical to that proposed in angiography. The median length of the actual stent was longer than that proposed in angiography (p = 0.0001). Conclusions Renal CTA has potential advantages as a tool adjunctive to angiography in appropriate stent sizing. Careful evaluation of the available CTA scans may be beneficial and should be considered prior to the planned procedure. PMID:27279870
A comparison of two brands of clopidogrel in patients with drug-eluting stent implantation.
Park, Yae Min; Ahn, Taehoon; Lee, Kyounghoon; Shin, Kwen-Chul; Jung, Eul Sik; Shin, Dong Su; Kim, Myeong Gun; Kang, Woong Chol; Han, Seung Hwan; Choi, In Suck; Shin, Eak Kyun
2012-07-01
Although generic clopidogrel is widely used, clinical efficacy and safety between generic and original clopidogrel had not been well evaluated. The aim of this study was to evaluate the clinical outcomes of 2 oral formulations of clopidogrel 75 mg tablets in patients with coronary artery disease (CAD) undergoing drug-eluting stent (DES) implantation. Between July 2006 and February 2009, 428 patients that underwent implantation with DES for CAD and completed >1 year of clinical follow-up were enrolled in this study. Patients were divided into the following 2 groups based on treatment formulation, Platless® (test formulation, n=211) or Plavix® (reference formulation, n=217). The incidence of 1-year major adverse cardiovascular and cerebrovascular event (MACCE) and stent thrombosis (ST) were retrospectively reviewed. The baseline demographic and procedural characteristics were not significantly different between two treatment groups. The incidence of 1-year MACCEs was 8.5% {19/211, 2 deaths, 4 myocardial infarctions (MIs), 2 strokes, and 11 target vessel revascularizations (TVRs)} in Platless® group vs. 7.4% (16/217, 4 deaths, 1 MI, 2 strokes, and 9 TVRs) in Plavix® group (p=0.66). The incidence of 1-year ST was 0.5% (1 definite and subacute ST) in Platless® group vs. 0% in Plavix® group (p=0.49). In this study, the 2 tablet preparations of clopidogrel showed similar rates of MACCEs, but additional prospective randomized studies with pharmacodynamics and platelet reactivity are needed to conclude whether generic clopidgrel may replace original clopidogrel.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, Qing-hui; Zhang, Wen; Liu, Qing-xin
PurposeThis study was designed to evaluate the safety and efficacy of transarterial chemoembolization (TACE) combined with intra-IVC implantation of an irradiation stent for the treatment of hepatocellular carcinoma (HCC) complicated by inferior vena cava tumor thrombosis (IVCTT).MethodsSixty-one consecutive patients with HCC complicated by IVCTT treated by TACE combined with IVC stenting were retrospectively analysed. IVC stenting was performed using a stent loaded with {sup 125}I seeds strands (the irradiation stent) in 33 patients (Group A) and 28 patients with a bare stent (Group B). Propensity score matching eliminated the baseline differences. Overall survival, oedema related to IVC obstruction remission ratemore » and procedure-related adverse events were compared between the two groups.ResultsThe adverse effect rate was similar for both Group A and Group B patients, and complications were adequately handled by medical treatment. TACE combined with implantation of an irradiation stent showed a significant median survival benefit over TACE combined with a bare stent, with a median survival time of 203.0 ± 28.135 days versus 93.0 ± 24.341 days (p = 0.006). The propensity score-matched (24 pairs) cohort analyses (200 ± 31.231 days vs. 66 ± 23.270 days, p = 0.019). The oedema remission rate was 97.0 % in group A patients and 96.4 % in group B, respectively. TACE-irradiation stent and object tumor response were the independent prognostic factors of favorable survival.ConclusionsTACE combined with irradiation stent implantation is a safe and effective treatment modality for patients with HCC complicated by IVCTT and may extend their survival time.« less
Tonn, H; Mall, W; Schneider, K-D; Schönhofer, B
2008-10-01
Tracheobronchial stents are inserted mainly in cases of malignant and benign airway stenosis. Further indications are esophago-tracheal fistulas, mediastinal fistulas and tracheomalacia. A retrospective analysis was conducted on patients' records, information provided by the general practitioners and relatives of the patients from July 1993 to December 2006 in the Department of Pneumology of the Heidehaus Hospital Hannover (since 6/05 Department of Pneumology and Internal Intensive Care Medicine, Oststadt-Heidehaus Hospital). During the observation period of 13 years a total of 269 stents (177 permanent, 92 temporary) were implanted in 207 patients (1.3 stents per patient). The vast majority of patients (173/207) suffered from an underlying malignancy. About half of the stents were deployed in the trachea. The median length of placement was 116 days in patients with malignancies and 313 days in patients with benign diseases. In about 40 % of the patients notable complications were observed which were directly or indirectly associated with the stents. These findings show the importance of a critical indication for stent implantation. In benign diseases a stent can remain for years inside the tracheobronchial system, if it is well tolerated in the beginning. In malignant diseases the result depends decisively on the stage of the tumour: has the stent been implanted before any other tumour therapy is started or is it an end-stage tumor with no other therapeutic option? In general, complications of stents occur quite frequently. The analysis of stent data leads to some aspects for the prevention of stent-related complications. There should be a strict indication and appropriate choice of stent material. Nevertheless, there remains an ethical dilemma in patients with end-stage disease as to whether to implant a stent or to do nothing against the tumor, because the benefit immediately after stent insertion vanishes with progression of the tumour, so causing extra complications.
Kodama, Atsuko; Kurita, Tairo; Kato, Osamu; Suzuki, Takahiko
2016-11-01
Aneurysmal degeneration of a saphenous vein graft (SVG) is a rare, but potentially fatal complication of coronary artery bypass graft (CABG) surgery. In this case report, a patient that had undergone prior CABG surgery and bare metal stent (BMS) implantation at the site of a stenotic SVG lesion presented at our hospital with chest pain, and an SVG aneurysm was detected at the previous BMS implantation site. In addition, the implanted BMS was fractured and floating in the SVG aneurysm. The SVG aneurysm was successfully occluded by percutaneous intervention, using a combination of distal covered stent deployment at the site of the anastomosis between the native coronary artery and the SVG and proximal coil embolization of the aneurysm.
Seiffert, Moritz; Diemert, Patrick; Koschyk, Dietmar; Schirmer, Johannes; Conradi, Lenard; Schnabel, Renate; Blankenberg, Stefan; Reichenspurner, Hermann; Baldus, Stephan; Treede, Hendrik
2013-06-01
This study sought to report on the feasibility and early results of transcatheter aortic valve implantation employing a second-generation device in a series of patients with pure aortic regurgitation. Efficacy and safety of transcatheter aortic valve implantation in patients with calcific aortic stenosis and high surgical risk has been demonstrated. However, experience with implantation for severe noncalcified aortic regurgitation has been limited due to increased risk for valve dislocation or annular rupture. Five patients (mean age: 66.6 ± 7 years) underwent transapical implantation of a JenaValve (JenaValve Technology GmbH, Munich, Germany) transcatheter heart valve for moderate to severe, noncalcified aortic regurgitation. All patients were considered high risk for surgical aortic valve replacement after evaluation by an interdisciplinary heart team (logistic EuroSCORE [European System for Cardiac Operative Risk Evaluation] range 3.1% to 38.9%). Procedural and acute clinical outcomes were analyzed. Implantation was successful in all cases without relevant remaining aortic regurgitation or signs of stenosis in any of the patients. No major device- or procedure-related adverse events occurred and all 5 patients were alive with improved exercise tolerance at 3-month follow-up. Noncalcified aortic regurgitation continues to be a challenging pathology for transcatheter aortic valve implantation due to the risk for insufficient anchoring of the valve stent within the aortic annulus. This report provides first evidence that the JenaValve prosthesis may be a reasonable option in these specific patients due to its unique stent design, clipping the native aortic valve leaflets, and offering promising early results. Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
[Successful correction with stent-graft of coronary artery rupture after angioplasty].
Demin, V V
2003-01-01
Rupture and perforation of coronary arteries complicate in average 0.5% of radiosurgical coronary interventions and often are accompanied by serious consequences and high mortality. According to-type of coronary perforation different methods of correction are used, ranging from conservative measures to urgent cardiosurgical interventions. Coronary stent-grafts with 'sandwich' type of construction ore composed from two metal stents and PTFE layer between them. Development of such stents enabled effective radioguided endovascular repair of coronary ruptures. The paper presents the first Russian experience of stout-graft implantation for coronary artery rupture occurred during direct stenting of proximal anterior descending artery and balloon angioplasty in distal segment. The rupture occurred probably because of wall fragility between affected segment and muscular bridge. Stent-graft JoStent 16 mm in length connected with 3-mm balloon was implanted with subsequent complete restitution of blood flow, resolution of pain syndrome and ECG normalization. Echocardiography in operative theatre and one day after surgery showed no intrapericardial fluid. Stent-graft devices for urgent implantation in cases of coronary rupture must be included into obligatory equipment of radiosurgical facilities.
Mytsyk, Miroslawa; Grapow, Martin T R; Shahinian, Jasmin; Maurer, Markus; Gurke, Lorenz; Eckstein, Friedrich S
2016-07-16
An incomplete traumatic rupture of the ascending aorta is a rare but life-threatening condition. Hence, the assessment of the extent of the injury prior to therapy is crucial. We report a case of a 50-year-old male with traumatic aortic rupture who underwent emergency surgery after the evaluation of computed tomography scan (CT-scan). The surgical treatment involved replacement of the ascending aorta and stent implantation in descending aorta due to its covered rupture.
Rogacka, Renata; Chieffo, Alaide; Michev, Iassen; Airoldi, Flavio; Latib, Azeem; Cosgrave, John; Montorfano, Matteo; Carlino, Mauro; Sangiorgi, Giuseppe M; Castelli, Alfredo; Godino, Cosmo; Magni, Valeria; Aranzulla, Tiziana C; Romagnoli, Enrico; Colombo, Antonio
2008-02-01
The purpose of this study was to evaluate the safety of dual antiplatelet therapy in patients in whom long-term anticoagulation (AC) with warfarin is recommended. The optimal antithrombotic strategy after percutaneous coronary intervention (PCI) for patients receiving AC is unclear. Consecutive patients who underwent stent implantation and were discharged on triple therapy (defined as the combination of aspirin and thienopyridines and AC) were analyzed. Of the 127 patients with 224 lesions, 86.6% were men, with a mean age of 69.9 +/- 8.8 years. Drug-eluting stents (DES) were positioned in 71 (55.9%), and bare-metal stents (BMS) were positioned in 56 (44.1%) patients. Atrial fibrillation (AF) was the main indication (59.1%) for AC treatment. The mean triple therapy duration was 5.6 +/- 4.6 months, and clinical follow-up was 21.0 +/- 19.8 months. During the triple therapy period, 6 patients (4.7%) developed major bleeding complications; 67% occurred within the first month. No significant differences between DES and BMS were observed in the incidence of major (5.6% vs. 3.6%, respectively, p = 1.0) and minor (1.4% vs. 3.6%, respectively, p = 0.57) bleeding and mortality (5.6% vs. 1.8%, respectively, p = 0.39). A significant difference was observed in favor of DES in target vessel revascularization (14.1% vs. 26.8%, p = 0.041). While receiving triple therapy, major bleeding occurred in 4.7% of patients; one-half of the events were lethal, and most occurred within the first month.
Cardiac Procedures and Surgeries
... or cutoff. Often combined with implantation of a stent (see below) to help prop the artery open ... or cutoff. Often combined with implantation of a stent (see below) to help prop the artery open ...
Targeting In-Stent-Stenosis with RGD- and CXCL1-Coated Mini-Stents in Mice.
Simsekyilmaz, Sakine; Liehn, Elisa A; Weinandy, Stefan; Schreiber, Fabian; Megens, Remco T A; Theelen, Wendy; Smeets, Ralf; Jockenhövel, Stefan; Gries, Thomas; Möller, Martin; Klee, Doris; Weber, Christian; Zernecke, Alma
2016-01-01
Atherosclerotic lesions that critically narrow the artery can necessitate an angioplasty and stent implantation. Long-term therapeutic effects, however, are limited by excessive arterial remodeling. We here employed a miniaturized nitinol-stent coated with star-shaped polyethylenglycole (star-PEG), and evaluated its bio-functionalization with RGD and CXCL1 for improving in-stent stenosis after implantation into carotid arteries of mice. Nitinol foils or stents (bare metal) were coated with star-PEG, and bio-functionalized with RGD, or RGD/CXCL1. Cell adhesion to star-PEG-coated nitinol foils was unaltered or reduced, whereas bio-functionalization with RGD but foremost RGD/CXCL1 increased adhesion of early angiogenic outgrowth cells (EOCs) and endothelial cells but not smooth muscle cells when compared with bare metal foils. Stimulation of cells with RGD/CXCL1 furthermore increased the proliferation of EOCs. In vivo, bio-functionalization with RGD/CXCL1 significantly reduced neointima formation and thrombus formation, and increased re-endothelialization in apoE-/- carotid arteries compared with bare-metal nitinol stents, star-PEG-coated stents, and stents bio-functionalized with RGD only. Bio-functionalization of star-PEG-coated nitinol-stents with RGD/CXCL1 reduced in-stent neointima formation. By supporting the adhesion and proliferation of endothelial progenitor cells, RGD/CXCL1 coating of stents may help to accelerate endothelial repair after stent implantation, and thus may harbor the potential to limit the complication of in-stent restenosis in clinical approaches.
Targeting In-Stent-Stenosis with RGD- and CXCL1-Coated Mini-Stents in Mice
Weinandy, Stefan; Schreiber, Fabian; Megens, Remco T. A.; Theelen, Wendy; Smeets, Ralf; Jockenhövel, Stefan; Gries, Thomas; Möller, Martin; Klee, Doris; Weber, Christian; Zernecke, Alma
2016-01-01
Atherosclerotic lesions that critically narrow the artery can necessitate an angioplasty and stent implantation. Long-term therapeutic effects, however, are limited by excessive arterial remodeling. We here employed a miniaturized nitinol-stent coated with star-shaped polyethylenglycole (star-PEG), and evaluated its bio-functionalization with RGD and CXCL1 for improving in-stent stenosis after implantation into carotid arteries of mice. Nitinol foils or stents (bare metal) were coated with star-PEG, and bio-functionalized with RGD, or RGD/CXCL1. Cell adhesion to star-PEG-coated nitinol foils was unaltered or reduced, whereas bio-functionalization with RGD but foremost RGD/CXCL1 increased adhesion of early angiogenic outgrowth cells (EOCs) and endothelial cells but not smooth muscle cells when compared with bare metal foils. Stimulation of cells with RGD/CXCL1 furthermore increased the proliferation of EOCs. In vivo, bio-functionalization with RGD/CXCL1 significantly reduced neointima formation and thrombus formation, and increased re-endothelialization in apoE-/- carotid arteries compared with bare-metal nitinol stents, star-PEG-coated stents, and stents bio-functionalized with RGD only. Bio-functionalization of star-PEG-coated nitinol-stents with RGD/CXCL1 reduced in-stent neointima formation. By supporting the adhesion and proliferation of endothelial progenitor cells, RGD/CXCL1 coating of stents may help to accelerate endothelial repair after stent implantation, and thus may harbor the potential to limit the complication of in-stent restenosis in clinical approaches. PMID:27192172
Chandra, Praveen; Kumar, Tarun
2014-01-01
A prospective, multicenter, post marketing surveillance study to evaluate the safety and effectiveness of the Superia-Sirolimus Eluting Coronary Stent System (SSECSS) implanted during routine clinical practice in India. 1. To study the MACE and in stent and In-segment Loss at Six Months (in a pre selected group of 50 patients). 1. Clinical and procedural success. This is a prospective, open label, single-arm, multicenter (16 sites), post marketing observational study enrolling patients implanted with Superia-Sirolimus Eluting Coronary Stent (SSECS) in routine clinical practice in India. A total of 200 Patients of coronary Artery Disease (CAD) implanted with Superia-Sirolimus Eluting Coronary Stent (SSECS) were enrolled. Clinical assessments were done at 30 days, 180 days and at 1, 2 years either telephonically or office visit. A cohort of 50 pre-selected patients were followed up for angiographic evaluation at 180 days. MACE at 12 month of follow up was 1.71%.Late lumen loss, in segment was 0.14 and in stent was 0.10 mm at 6 month of follow-up. TLR was required only in 2 patients. Superia stent is as safe as other biodegradable polymer stent in the market and time has come for biodegradable polymer stent with thin struts. Copyright © 2014 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.
Impact of nitinol stent surface processing on in-vivo nickel release and biological response.
Nagaraja, Srinidhi; Sullivan, Stacey J L; Stafford, Philip R; Lucas, Anne D; Malkin, Elon
2018-05-01
Although nitinol is widely used in percutaneous cardiovascular interventions, a causal relationship between nickel released from implanted cardiovascular devices and adverse systemic or local biological responses has not been established. The objective of this study was to investigate the relationship between nitinol surface processing, in-vivo nickel release, and biocompatibility. Nitinol stents manufactured using select surface treatments were implanted into the iliac arteries of minipigs for 6 months. Clinical chemistry profile, complete blood count, serum and urine nickel analyses were performed periodically during the implantation period. After explant, stented arteries were either digested and analyzed for local nickel concentration or fixed and sectioned for histopathological analysis of stenosis and inflammation within the artery. The results indicated that markers for liver and kidney function were not different than baseline values throughout 180 days of implantation regardless of surface finish. In addition, white blood cell, red blood cell, and platelet counts were similar to baseline values for all surface finishes. Systemic nickel concentrations in serum and urine were not significantly different between processing groups and comparable to baseline values during 180 days of implantation. However, stents with non-optimized surface finishing had significantly greater nickel levels in the surrounding artery compared to polished stents. These stents had increased stenosis with potential for local inflammation compared to polished stents. These findings demonstrate that proper polishing of nitinol surfaces can reduce in-vivo nickel release locally, which may aid in minimizing adverse inflammatory reactions and restenosis. Nitinol is a commonly used material in cardiovascular medical devices. However, relationships between nitinol surface finishing, in-vivo metal ion release, and adverse biological responses have yet to be established. We addressed this knowledge gap by implanting single and overlapped nitinol stents with different surface finishes to assess systemic impact on minipigs (i.e. serum and urine nickel levels, liver and kidney function, immune and blood count) over the 6 month implantation period. In addition, nickel levels and histopathology in stented arteries were analyzed on explant to determine relationships between surface processing and local adverse tissue reactions. The findings presented here highlight the importance of surface processing on in-vivo nickel release and subsequent impact on local biological response for nitinol implants. Published by Elsevier Ltd.
Emmert, Maximilian Y; Weber, Benedikt; Behr, Luc; Sammut, Sebastien; Frauenfelder, Thomas; Wolint, Petra; Scherman, Jacques; Bettex, Dominique; Grünenfelder, Jürg; Falk, Volkmar; Hoerstrup, Simon P
2014-01-01
While transcatheter aortic valve implantation (TAVI) has rapidly evolved for the treatment of aortic valve disease, the currently used bioprostheses are prone to continuous calcific degeneration. Thus, autologous, cell-based, living, tissue-engineered heart valves (TEHVs) with regeneration potential have been suggested to overcome these limitations. We investigate the technical feasibility of combining the concept of TEHV with transapical implantation technology using a state-of-the-art transcatheter delivery system facilitating the exact anatomical position in the systemic circulation. Trileaflet TEHVs fabricated from biodegradable synthetic scaffolds were sewn onto self-expanding Nitinol stents seeded with autologous marrow stromal cells, crimped and transapically delivered into the orthotopic aortic valve position of adult sheep (n = 4) using the JenaValve transapical TAVI System (JenaValve, Munich, Germany). Delivery, positioning and functionality were assessed by angiography and echocardiography before the TEHV underwent post-mortem gross examination. For three-dimensional reconstruction of the stent position of the anatomically oriented system, a computed tomography analysis was performed post-mortem. Anatomically oriented, transapical delivery of marrow stromal cell-based TEHV into the orthotopic aortic valve position was successful in all animals (n = 4), with a duration from cell harvest to TEHV implantation of 101 ± 6 min. Fluoroscopy and echocardiography displayed sufficient positioning, thereby entirely excluding the native leaflets. There were no signs of coronary obstruction. All TEHV tolerated the loading pressure of the systemic circulation and no acute ruptures occurred. Animals displayed intact and mobile leaflets with an adequate functionality. The mean transvalvular gradient was 7.8 ± 0.9 mmHg, and the mean effective orifice area was 1.73 ± 0.02 cm(2). Paravalvular leakage was present in two animals, and central aortic regurgitation due to a single-leaflet prolapse was detected in two, which was primarily related to the leaflet design. No stent dislocation, migration or affection of the mitral valve was observed. For the first time, we demonstrate the technical feasibility of a transapical TEHV delivery into the aortic valve position using a commercially available and clinically applied transapical implantation system that allows for exact anatomical positioning. Our data indicate that the combination of TEHV and a state-of-the-art transapical delivery system is feasible, representing an important step towards translational, transcatheter-based TEHV concepts.
Wang, T; Liu, S; Zheng, Y B; Song, X P; Jiang, W J; Sun, B L; Wang, L G
2016-03-23
To study the feasibility and therapeutic effect of the application of (125)I seeds combined with biliary stent implantation on the treatment of malignant obstructive jaundice. Fifty patients with malignant obstructive jaundice treated from September 2010 to February 2013 in Yantai Yuhuangding Hospital were included in this study. Among them, 24 patients received biliary stent implantation combined with (125)I seeds intraluminal brachytherapy as experimental group, and 26 were treated by biliary stent implantation as control group.The total bilirubin, direct bilirubin and tumor markers (CA-199, CA-242, CEA) before and after surgery, the biliary stent patency status was assessed, and the survival time was evaluated. The 24 patients in experimental group were implanted with 30 (125)I seeds successfully in a total of 450 seeds. Jaundice was improved greatly in both groups. The CA-199 and CA-242 after treatment in the experimental group were significantly decreased than that before treatment (P=0.003 and P=0.004). CEA was also decreased, but showed no statistical significance (P>0.05). There were no significant improvement comparing the CA-199, CA-242 and CEA before and 2 months after surgery in the control group (P>0.05). The rate of biliary stent patency was 83.3% (20/24) in the experimental group and 57.7% (15/26) in the control group (P=0.048). The mean biliary stent patency time in the experimental group was 9.84 months (range 1-15.5 months). The mean biliary stent patency time in the control group was 5.57 months (range 0.8-9 months). There was a significant difference between the two groups (P=0.018). The median survival time was 10.2 months in the experimental group and 5.4 months in the control group (P<0.05). (125)I seeds combined with biliary stent implantation can inhibit the proliferation of vascular endothelial cells and the growth of tumor effectively, and can prolong the biliary stent patency time and the survival time obviously for patients with malignant obstructive jaundice, therefore, is a safe and effective treatment in this malignancy.
Ruiter, Matthijs S.; van Tiel, Claudia M.; Doornbos, Albert; Marinković, Goran; Strang, Aart C.; Attevelt, Nico J. M.; de Waard, Vivian; de Winter, Robbert J.; Steendam, Rob; de Vries, Carlie J. M.
2015-01-01
Background The introduction of drug-eluting stents (DES) has dramatically reduced restenosis rates compared with bare metal stents, but in-stent thrombosis remains a safety concern, necessitating prolonged dual anti-platelet therapy. The drug 6-Mercaptopurine (6-MP) has been shown to have beneficial effects in a cell-specific fashion on smooth muscle cells (SMC), endothelial cells and macrophages. We generated and analyzed a novel bioresorbable polymer coated DES, releasing 6-MP into the vessel wall, to reduce restenosis by inhibiting SMC proliferation and decreasing inflammation, without negatively affecting endothelialization of the stent surface. Methods Stents spray-coated with a bioresorbable polymer containing 0, 30 or 300 μg 6-MP were implanted in the iliac arteries of 17 male New Zealand White rabbits. Animals were euthanized for stent harvest 1 week after implantation for evaluation of cellular stent coverage and after 4 weeks for morphometric analyses of the lesions. Results Four weeks after implantation, the high dose of 6-MP attenuated restenosis with 16% compared to controls. Reduced neointima formation could at least partly be explained by an almost 2-fold induction of the cell cycle inhibiting kinase p27Kip1. Additionally, inflammation score, the quantification of RAM11-positive cells in the vessel wall, was significantly reduced in the high dose group with 23% compared to the control group. Evaluation with scanning electron microscopy showed 6-MP did not inhibit strut coverage 1 week after implantation. Conclusion We demonstrate that novel stents coated with a bioresorbable polymer coating eluting 6-MP inhibit restenosis and attenuate inflammation, while stimulating endothelial coverage. The 6-MP-eluting stents demonstrate that inhibition of restenosis without leaving uncovered metal is feasible, bringing stents without risk of late thrombosis one step closer to the patient. PMID:26389595
Kimura, Takeshi; Morimoto, Takeshi; Nakagawa, Yoshihisa; Kawai, Kazuya; Miyazaki, Shunichi; Muramatsu, Toshiya; Shiode, Nobuo; Namura, Masanobu; Sone, Takahito; Oshima, Shigeru; Nishikawa, Hideo; Hiasa, Yoshikazu; Hayashi, Yasuhiko; Nobuyoshi, Masakiyo; Mitudo, Kazuaki
2012-01-31
There is a scarcity of long-term data from large-scale drug-eluting stent registries with a large enough sample to evaluate low-frequency events such as stent thrombosis (ST). Five-year outcomes were evaluated in 12 812 consecutive patients undergoing sirolimus-eluting stent (SES) implantation in the j-Cypher registry. Cumulative incidence of definite ST was low (30 day, 0.3%; 1 year, 0.6%; and 5 years, 1.6%). However, late and very late ST continued to occur without attenuation up to 5 years after sirolimus-eluting stent implantation (0.26%/y). Cumulative incidence of target lesion revascularization within the first year was low (7.3%). However, late target lesion revascularization beyond 1 year also continued to occur without attenuation up to 5 years (2.2%/y). Independent risk factors of ST were completely different according to the timing of ST onset, suggesting the presence of different pathophysiological mechanisms of ST according to the timing of ST onset: acute coronary syndrome and target of proximal left anterior descending coronary artery for early ST; side-branch stenting, diabetes mellitus, and end-stage renal disease with or without hemodialysis for late ST; and current smoking and total stent length >28 mm for very late ST. Independent risk factors of late target lesion revascularization beyond 1 year were generally similar to those risk factors identified for early target lesion revascularization. Late adverse events such as very late ST and late target lesion revascularization are continuous hazards, lasting at least up to 5 years after implantation of the first-generation drug-eluting stents (sirolimus-eluting stents), which should be the targets for developing improved coronary stents.
Evaluation of Polyurethane Nasolacrimal Duct Stents: In Vivo Studies in New Zealand Rabbits
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wilhelm, K.E., E-mail: wilhelm@uni-bonn.de; Grabolle, B.; Urbach, H.
2006-10-15
The purpose of this study was to evaluate the radiographic and biological effects of different polyurethane nasolacrimal duct stents in an animal model. Fifteen polyurethane nasolacrimal duct stents (n = 5 mushroom-type stents, n = 5 newly designed S-shaped TearLeader stents without hydrophilic coating, and n = 5 S-shaped TearLeader stents with hydrophilic coating) were implanted in the nasolacrimal ducts of eight unaffected New Zealand rabbits. One nasolacrimal system served as control. Clinical and radiographic follow-up was performed at 1-, 2-, and 4-week intervals, then after a 3-month interval, after which the animals were euthanized. All stents were implanted withoutmore » major periprocedural complications. The stents proved to be patent by the end of the procedure. During follow-up, all mushroom-type stents were occluded at 4 weeks. None of these stents opened to forced irrigation. Clinically, all rabbits demonstrated severe dacryocystitis. Three out of five TearLeader stents without hydrophilic coating were blocked at 4 weeks; one out of five was open to irrigation. Best results were observed in the stent group with hydrophilic coating. Follow-up dacryocystography demonstrated patent stents in nasolacrimal ducts of all animals after 4 weeks. In only one of five cases, the coated stent became partially occluded after 2 months. These animals were free of clinical symptoms. After 3 months, at least three out of five stents still opened to forced irrigation and only one stent was completely blocked. Dislocation of the stents was not observed. Refinement of the stent surface and stent design improves the results of nasolacrimal duct stenting in this animal model. Implantation of hydrophilic-coated S-shaped stents is highly superior to conventional mushroom-type stents and noncoated stent types. Hydrophilic coating seems to prevent foreign-body reactions, resulting in maximized stent patency.« less
Hemodynamic alterations after stent implantation in 15 cases of intracranial aneurysm.
Wang, Chao; Tian, Zhongbin; Liu, Jian; Jing, Linkai; Paliwal, Nikhil; Wang, Shengzhang; Zhang, Ying; Xiang, Jianping; Siddiqui, Adnan H; Meng, Hui; Yang, Xinjian
2016-04-01
Stent-assisted coiling technology has been widely used in the treatment of intracranial aneurysms. In the current study, we investigated the intra-aneurysmal hemodynamic alterations after stent implantation and their association with the aneurysm location. We first retrospectively studied 15 aneurysm cases [8 internal carotid artery-ophthalmic artery (ICA-OphA) aneurysms and 7 posterior communicating artery (PcoA) aneurysms] treated with Enterprise stents and coils. Then, based on the patient-specific geometries before and after stenting, we built virtual stenting computational fluid dynamics (CFD) simulation models. Before and after the stent deployment, the average wall shear stress (WSS) on the aneurysmal sac at systolic peak changed from 7.04 Pa (4.14 Pa, 15.77 Pa) to 6.04 Pa (3.86 Pa, 11.13 Pa), P = 0.001; the spatially averaged flow velocity in the perpendicular plane of the aneurysm dropped from 0.5 m/s (0.28 m/s, 0.7 m/s) to 0.33 m/s (0.25 m/s, 0.49 m/s), P = 0.001, respectively. Post stent implantation, the WSS in ICA-OphA aneurysms and PcoA aneurysms decreased by 14.4 % (P = 0.012) and 16.6 % (P = 0.018), respectively, and the flow velocity also reduced by 10.3 % (P = 0.029) and 10.5 % (P = 0.013), respectively. Changes in the WSS, flow velocity, and pressure were not significantly different between ICA-OphA and PcoA aneurysms (P > 0.05). Stent implantation did not significantly change the peak systolic pressure in either aneurysm type. After the stent implantation, both the intra-aneurysmal flow velocity and WSS decreased independently of aneurysm type (ICA-OphA and PcoA). Little change was observed in peak systolic pressure.
Kim, Joon-young; Han, Hyun-jung; Yun, Hun-young; Lee, Bora; Jang, Ha-young; Eom, Ki-dong; Park, Hee-myung
2008-01-01
To evaluate the potential utility of a self-expandable intratracheal nitinol stent with flared ends for the treatment of tracheal collapse in dogs, endotracheal stenting therapy was performed under fluoroscopic guidance in four dogs with severe tracheal collapse. During the 4 to 7 month follow-up, after stent implantation, clinical signs, including dyspnea and respiratory distress, dramatically improved in all dogs. The radiographs showed that the implanted stents improved the tracheal collapse, and there were no side effects such as collapse, shortening or migration of the stents. In conclusion, the self-expandable intratracheal nitinol stents provided adequate stability to the trachea and were effective for attenuating the clinical signs associated with severe tracheal collapse. PMID:18296893
Katz, L Jay; Erb, Carl; Carceller, Guillamet Amadeu; Fea, Antonio M; Voskanyan, Lilit; Wells, Jeffrey M; Giamporcaro, Jane Ellen
2015-01-01
Purpose To assess the safety and efficacy of one, two, or three trabecular microbypass stents in eyes with primary open-angle glaucoma (OAG) not controlled on ocular hypotensive medication. A total of 119 subjects were followed for 18 months postoperatively. Materials and methods Subjects with medicated intraocular pressure (IOP) 18–30 mmHg and postmedication-washout baseline IOP 22–38 mmHg were randomized to implantation of one, two, or three stents. Ocular hypotensive medication was to be used if postoperative IOP exceeded 18 mmHg. Results A total of 38 subjects were implanted with one stent, 41 subjects with two stents, and 40 subjects with three stents. Both month 12 IOP reduction ≥20% without ocular hypotensive medication vs baseline unmedicated IOP and month 12 unmedicated IOP ≤18 mmHg were achieved by 89.2%, 90.2%, and 92.1% of one-, two-, and three-stent eyes, respectively. Furthermore, 64.9%, 85.4%, and 92.1% of the three respective groups achieved unmedicated IOP ≤15 mmHg. Over the 18-month follow-up period, medication was required in seven one-stent subjects, four two-stent subjects, and three three-stent subjects. At 18 months, mean unmedicated IOP was 15.9±0.9 mmHg in one-stent subjects, 14.1±1.0 mmHg in two-stent subjects, and 12.2±1.1 mmHg in three-stent subjects. Month 18 IOP reduction was significantly greater (P<0.001) with implantation of each additional stent, with mean differences in reduction of 1.84 mmHg (95% confidence interval 0.96–2.73) for three-stent vs two-stent groups and 1.73 mmHg (95% confidence interval 0.83–2.64) for two-stent vs one-stent groups. Adverse events through 18 months were limited to cataract progression with best-corrected visual acuity loss and subsequent cataract surgery. Conclusion In this series, implantation of each additional stent resulted in significantly greater IOP reduction with reduced medication use. Titratability of stents as a sole procedure was shown to be effective and safe, with sustained effect through 18 months postoperatively in OAG not controlled with medication. PMID:26715834
Chiastra, Claudio; Grundeken, Maik J; Collet, Carlos; Wu, Wei; Wykrzykowska, Joanna J; Pennati, Giancarlo; Dubini, Gabriele; Migliavacca, Francesco
2018-05-17
The treatment of coronary bifurcations is challenging for interventional cardiologists. The Tryton stent (Tryton Medical, Inc., USA) is one of the few devices specifically designed for coronary bifurcations that underwent large clinical trials. Although the manufacturer provides specific recommendations to position the stent in the bifurcation side branch (SB) according to four radio-opaque markers under angiographic guidance, wrong device positioning may accidentally occur. In this study, the virtual bench testing approach was used to investigate the impact of wrong positioning of the Tryton stent in coronary bifurcations in terms of geometrical and biomechanical criteria. A finite element model of the left anterior descending/first diagonal coronary bifurcation was created with a 45° distal angle and realistic lumen diameters. A validated model of the Tryton stent mounted on stepped delivery balloon was used. All steps of the Tryton deployment sequence were simulated. Three Tryton positions, namely 'proximal', 'recommended', and 'distal' positions, obtained by progressively implanting the stent more distally in the SB, were compared. The 'recommended' case exhibited the lowest ostial area stenosis (44.8 vs. 74.3% ('proximal') and 51.5% ('distal')), the highest diameter at the SB ostium (2.81 vs. 2.70 mm ('proximal') and 2.54 mm ('distal')), low stent malapposition (9.9 vs. 16.3% ('proximal') and 8.5% ('distal')), and the lowest peak wall stress (0.37 vs. 2.20 MPa ('proximal') and 0.71 MPa ('distal')). In conclusion, the study shows that a 'recommended' Tryton stent positioning may be required for optimal clinical results.
Li, Hu; Choi, Cheol Ung; Oh, Dong Joo
2017-01-01
We report herein the optical coherence tomography (OCT) and stent boost imaging guided bioresorbable vascular scaffold (BVS) implantation for right coronary artery (RCA) chronic total occlusion (CTO) lesion. The gold standard for evaluating BVS expansion after percutaneous coronary intervention is OCT. However, stent boost imaging is a new technique that improves fluoroscopy-based assessments of stent overlapping, and the present case shows clinical usefulness of OCT and stent boost imaging guided ‘overlapping’ BVS implantation via antegrade approach for a typical RCA CTO lesion. PMID:28792157
Collagen Matrix Remodeling in Stented Pulmonary Arteries after Transapical Heart Valve Replacement.
Ghazanfari, Samaneh; Driessen-Mol, Anita; Hoerstrup, Simon P; Baaijens, Frank P T; Bouten, Carlijn V C
2016-01-01
The use of valved stents for minimally invasive replacement of semilunar heart valves is expected to change the extracellular matrix and mechanical function of the native artery and may thus impair long-term functionality of the implant. Here we investigate the impact of the stent on matrix remodeling of the pulmonary artery in a sheep model, focusing on matrix composition and collagen (re)orientation of the host tissue. Ovine native pulmonary arteries were harvested 8 (n = 2), 16 (n = 4) and 24 (n = 2) weeks after transapical implantation of self-expandable stented heart valves. Second harmonic generation (SHG) microscopy was used to assess the collagen (re)orientation of fresh tissue samples. The collagen and elastin content was quantified using biochemical assays. SHG microscopy revealed regional differences in collagen organization in all explants. In the adventitial layer of the arterial wall far distal to the stent (considered as the control tissue), we observed wavy collagen fibers oriented in the circumferential direction. These circumferential fibers were more straightened in the adventitial layer located behind the stent. On the luminal side of the wall behind the stent, collagen fibers were aligned along the stent struts and randomly oriented between the struts. Immediately distal to the stent, however, fibers on both the luminal and the adventitial side of the wall were oriented in the axial direction, demonstrating the stent impact on the collagen structure of surrounding arterial tissues. Collagen orientation patterns did not change with implantation time, and biochemical analyses showed no changes in the trend of collagen and elastin content with implantation time or location of the vascular wall. We hypothesize that the collagen fibers on the adventitial side of the arterial wall and behind the stent straighten in response to the arterial stretch caused by oversizing of the stent. However, the collagen organization on the luminal side suggests that stent-induced remodeling is dominated by contact guidance. © 2016 S. Karger AG, Basel.
Radiopaque biodegradable stent for duct-to-duct biliary reconstruction in pigs.
Tanimoto, Yoshisato; Tashiro, Hirotaka; Mikuriya, Yoshihiro; Kuroda, Shintaro; Hashimoto, Masakazu; Kobayashi, Tsuyoshi; Taniura, Tokunori; Ohdan, Hideki
2016-06-01
Biliary stricture is a common cause of morbidity after liver transplantation. We previously developed a duct-to-duct biliary anastomosis technique using a biodegradable stent tube and confirmed the feasibility and safety of biliary stent use. However, the duration and mechanism of biliary stent absorption in the common bile duct remain unclear. Radiopaque biodegradable biliary stents were created using a copolymer of L-lactide and ε-caprolactone (70: 30) and coated with barium sulfate. Stents were surgically implanted in the common bile duct of 11 pigs. Liver function tests and computed tomography (CT) scans were performed postoperatively, and autopsies were conducted 6 months after biliary stent implantation. After the surgery, all 11 pigs had normal liver function and survived without any significant complications such as biliary leakage. A CT scan at 2 months post-procedure showed that the biliary stents were located in the hilum of the liver. The stents were not visible by CT scan at the 6-month follow-up examination. The surgical implantation of radiopaque biodegradable biliary stents in biliary surgery represents a new option for duct-to-duct biliary reconstruction. This technique appears to be feasible and safe and is not associated with any significant biliary complications. The advantage of coated biliary stent use is that it may be visualized using abdominal radiography such as CT.
Maruo, Hirotoshi; Tsuyuki, Hajime; Kojima, Tadahiro; Koreyasu, Ryohei; Nakamura, Koichi; Higashi, Yukihiro; Shoji, Tsuyoshi; Yamazaki, Masanori; Nishiyama, Raisuke; Ito, Tatsuhiro; Koike, Kota; Ikeda, Takashi; Takayanagi, Yasuhiro; Kubota, Hiroyuki
2017-11-01
We clinically investigated 34 patients with obstructive colorectal cancer who underwent placement of a colonic stent as a bridge to surgery(BTS), focusing on endoscopic findings after stent placement.Twenty -nine patients(85.3%)underwent colonoscopy after stent placement, and the entire large intestine could be observed in 28(96.6%).Coexisting lesions were observed in 22(78.6%)of these 28 patients.The lesions comprised adenomatous polyps in 17 patients(60.7%), synchronous colon cancers in 5 patients(17.9%), and obstructive colitis in 3 patients(10.7%), with some overlapping cases.All patients with multiple cancers underwent one-stage surgery, and all lesions were excised at the same time.Colonoscopy after colonic stent placement is important for preoperative diagnosis of coexisting lesions and planning the extent of resection. These considerations support the utility of colonic stenting for BTS.
Local delivery of sirolimus nanoparticles for the treatment of in-stent restenosis.
Zago, Alexandre C; Raudales, José C; Attizzani, Guilherme; Matte, Bruno S; Yamamoto, German I; Balvedi, Julise A; Nascimento, Ludmila; Kosachenco, Beatriz G; Centeno, Paulo R; Zago, Alcides J
2013-02-01
To test the local delivery of sirolimus nanoparticles following percutaneous transluminal coronary angioplasty (PTCA) to treat in-stent restenosis (ISR) in a swine model. Coronary bare-metal stent (BMS) implantation reduces major adverse cardiac events when compared with PTCA; however, ISR rates remain high. Eighteen swine underwent BMS deployment guided by intravascular ultrasound (IVUS). Of these, 16 developed ISR (1 stent/swine) and underwent angioplasty with a noncompliant balloon (PTCA-NC). The animals were then randomized into four groups for local infusion of sirolimus nanoparticles through a porous balloon catheter, as follows: (1) PTCA-NC alone (control); (2) PTCA-NC + (polylactic acid)-based nanoparticle formulation (anionic 1); (3) PTCA-NC + (polylactic-co-glycolic acid)-based nanoparticle formulation (anionic 2); and (4) PTCA-NC + Eudragit RS nanoparticle formulation (cationic). Coronary angiography and IVUS follow-up were performed 28 days after ISR treatment. There was one episode of acute coronary occlusion with the cationic formulation. Late area loss was similar in all groups at 28 days according to IVUS. However, luminal volume loss (control = 20.7%, anionic 1 = 4.0%, anionic 2 = 6.7%, cationic = 9.6%; P = 0.01) and neointimal volume gain (control = 68.7%, anionic 1 = 17.4%, anionic 2 = 29.5%, cationic = 31.2%; P = 0.019) were significantly reduced in all treatment groups, especially in anionic 1. PTCA-NC followed by local infusion of sirolimus nanoparticles was safe and efficacious to reduce neointima in this model, and this strategy may be a promising treatment for BMS ISR. Further studies are required to validate this method in humans. Copyright © 2012 Wiley Periodicals, Inc.
Akif Cakar, Mehmet; Tatli, Ersun; Tokatli, Alptug; Kilic, Harun; Gunduz, Huseyin; Akdemir, Ramazan
2018-03-16
Percutaneous endovascular therapy is an accepted and preferred procedure for symptomatic subclavian artery disease. However, the technical feasibility and effectiveness of treating chronic total occlusion of the subclavian artery with this approach is uncertain. We aimed to evaluate the initial and mid-term results of endovascular therapy for patients with symptomatic chronic total occlusion of the left subclavian artery. Consecutive patients who underwent balloon angioplasty and stenting for chronic total occlusion of the left subclavian artery between January 2010 and February 2014 were included. Overall, 16 patients (10 male, 6 female; mean age 56 ± 13 years) underwent balloon angioplasty and stenting for chronic total occlusion of the left subclavian artery - 6 (37.5%) had arm claudication, 8 (50.0%) had vertebrobasilar insufficiency and 2 (12.5%) had coronary steal. 18 balloon-expandable stents were implanted to 15 patients. The central luminal passage was not achieved in one patient because of the subintimal position of guidewire (procedural success rate 93.8%). There were no procedure-related complications. Mean preprocedural and postprocedural systolic blood pressure differences between the upper extremities were 37 ± 13 (range 25-60) mmHg and 11 ± 9 (range 5-38) mmHg, respectively; the improvement was statistically significant. Outpatient follow-up revealed one asymptomatic restenosis at two years. Patency rate at two years was 93.3%. Balloon angioplasty and stenting for chronic total occlusion of the left subclavian artery is safe and effective, with good acute success rate and mid-term patency. Prospective randomised studies on larger patient populations would provide more precise results.
Distribution of angiographic measures of restenosis after drug-eluting stent implantation.
Byrne, R A; Eberle, S; Kastrati, A; Dibra, A; Ndrepepa, G; Iijima, R; Mehilli, J; Schömig, A
2009-10-01
A bimodal distribution of measures of restenosis has been demonstrated at 6-8 months after bare metal stent implantation. Drug-eluting stent (DES) treatment has attenuated the impact of certain factors (eg, diabetes) on restenosis but its effect on the distribution of indices of restenosis is not known. To perform a detailed analysis of the metrics of restenosis indices after DES implantation. Design, settings, Prospective observational study of patients undergoing DES implantation (Cypher, sirolimus-eluting stent; or Taxus, paclitaxel-eluting stent) at two German centres, with repeat angiography scheduled at 6-8 months after coronary stenting. In-stent late luminal loss (LLL) and in-segment percentage diameter stenosis (%DS) as determined by quantitative coronary angiography at recatheterisation. Paired cineangiograms were available for 2057 patients. Overall mean (SD) LLL was 0.31 (0.50) mm; mean (SD) %DS was 30.3 (15.7)%. Distribution of both LLL and %DS differed significantly from normal (Kolmogorov-Smirnov test; p<0.001 for each). For both parameters a mixed distribution model better described the data (likelihood ratio test with 3df; p<0.001 for each). This consisted of two normally distributed subpopulations with means (SD) of 0.10 (0.25) mm and 0.69 (0.60) mm for LLL, and means (SD) of 22.2 (8.6)% and 40.1 (16.6)% for %DS. The results were consistent across subgroups of DES type, "on-label" versus "off-label" indication, and presence or absence of diabetes. LLL and %DS at follow-up angiography after DES implantation have a complex mixed distribution that may be accurately represented by a bimodal distribution model. The introduction of DES treatment has not resulted in elimination of a variable propensity to restenosis among subpopulations of patients with stented lesions.
Imbarrato, Greg; Gordhan, Ajeet
2018-01-01
A 74-year-old male developed cervical carotid artery psuedoaneurysm 8 months after carotid endarterectomy. The patient was successfully managed with dual implantation of flow-diverter and conventional carotid stent. Flow-diverter was placed across the neck of pseudoaneurysm to provide flow diversion while carotid stent was implanted within the lumen of the expanded flow-diverter to approximate and hold the flow diverter proximal and distal to the pseudoaneurysm. Follow-up ultrasonography revealed complete resolution of the pseudoaneurysm. PMID:29535899
Optimization of stent implantation using a high pressure inflation protocol.
Vallurupalli, Srikanth; Bahia, Amit; Ruiz-Rodriguez, Ernesto; Ahmed, Zubair; Hakeem, Abdul; Uretsky, Barry F
2016-01-01
High-pressure inflation is the universal standard for stent deployment but a specific protocol for its use is lacking. We developed a standardized "pressure optimization protocol" (POP) using time to inflation pressure stability as an endpoint for determining the required duration of stent inflation. The primary study purpose was to determine the stent inflation time (IT) in a large patient cohort using the standardized inflation protocol, to correlate various patient and lesion characteristics with IT, and ascertain in an in vitro study the time for pressure accommodation within an inflation system. Six hundred fifteen stent implants in 435 patients were studied. Multivariate analysis was performed to determine predictors of longer ITs. In an in vitro study, various stents and balloons were inflated in air to determine the pressure accommodation time of the inflation system. The mean stent IT was 104 ± 41 sec (range 30-380 sec). Stent length was the only predictor of prolonged stent inflation. The "accommodation time" in vitro of the stent inflation system itself was 33 ± 24 sec. The protocol was safe requiring premature inflation termination in <3% of stent implants. No serious adverse events occurred. Achieving stable inflation pressure requires on average over 100 sec and may require several minutes in individual cases. Stent length increases IT. These results suggest that the widespread practice of rapid inflation/deflation may not be sufficient to fully expand the stent and that the use of a pressure stability protocol will allow for safe, predictable, and more complete stent deployment. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.
Delayed complications after flow-diverter stenting: reactive in-stent stenosis and creeping stents.
Cohen, José E; Gomori, John Moshe; Moscovici, Samuel; Leker, Ronen R; Itshayek, Eyal
2014-07-01
We assessed the frequency and severity of changes in stent configuration and location after the treatment of intracranial aneurysms, and patterns of in-stent stenosis. We retrospectively reviewed data for consecutive aneurysm patients managed with endovascular implantation of flow-diverter stents (Silk Flow Diverter [Balt Extrusion, Montmorency, France] and Pipeline Embolization Device [ev3/Coviden, Minneapolis, MN, USA]) from October 2011 to July 2012. Routine 2, 6, 9-12, and 16-20 month follow-up angiograms were compared, with a focus on changes in stent configuration and location from immediately after deployment to angiographic follow-up, and the incidence and development of in-stent stenosis. Thirty-four patients with 42 aneurysms met inclusion criteria. The Silk device was implanted in 16 patients (47%, single device in 15), the Pipeline device in 18 (53%, single device in 16). On first follow-up angiography, in-stent stenosis was observed in 38% of Silk devices and 39% of Pipeline devices. In-stent stenosis was asymptomatic in 12 of 13 patients. One woman presented with transient ischemic attacks and required stent angioplasty due to end tapering and mild, diffuse in-stent stenosis. Configuration and location changes, including stent creeping and end tapering were seen in 2/16 patients (13%) with Silk devices, and 0/18 patients with Pipeline devices. We describe stent creeping and end tapering as unusual findings with the potential for delayed clinical complications. In-stent stenosis, with a unique behavior, is a frequent angiographic finding observed after flow-diverter stent implant. The stenosis is usually asymptomatic; however, close clinical and angiographic monitoring is mandatory for individualized management. Copyright © 2013 Elsevier Ltd. All rights reserved.
Advantages and disadvantages of biodegradable platforms in drug eluting stents.
Rodriguez-Granillo, Agustina; Rubilar, Bibiana; Rodriguez-Granillo, Gaston; Rodriguez, Alfredo E
2011-03-26
Coronary angioplasty with drug-eluting stent (DES) implantation is currently the most common stent procedure worldwide. Since the introduction of DES, coronary restenosis as well as the incidence of target vessel and target lesion revascularization have been significantly reduced. However, the incidence of very late stent thrombosis beyond the first year after stent deployment has more commonly been linked to DES than to bare-metal stent (BMS) implantation. Several factors have been associated with very late stent thrombosis after DES implantation, such as delayed healing, inflammation, stent mal-apposition and endothelial dysfunction. Some of these adverse events were associated with the presence of durable polymers, which were essential to allow the elution of the immunosuppressive drug in the first DES designs. The introduction of erodable polymers in DES technology has provided the potential to complete the degradation of the polymer simultaneously or immediately after the release of the immunosuppressive drug, after which a BMS remains in place. Several DES designs with biodegradable (BIO) polymers have been introduced in preclinical and clinical studies, including randomized trials. In this review, we analyze the clinical results from 6 observational and randomized studies with BIO polymers and discuss advantages and disadvantages of this new technology.
Guimaraes, Marcelo; Schonholz, Claudio; Hannegan, Christopher; Anderson, Michael Bret; Shi, June; Selby, Bayne
2012-08-01
To report the technique and acute technical results associated with the PowerWire Radiofrequency (RF) Guidewire used to recanalize central vein occlusions (CVOs) after the failure of conventional endovascular techniques. A retrospective study was conducted from January 2008 to December 2011, which identified all patients with CVOs who underwent treatment with a novel RF guide wire. Forty-two symptomatic patients (with swollen arm or superior vena cava [SVC] syndrome) underwent RF wire recanalization of 43 CVOs, which were then implanted with stents. The distribution of CVOs in central veins was as follows: six subclavian, 29 brachiocephalic, and eight SVC. All patients had a history of central venous catheter placement. Patients were monitored with regular clinical evaluations and central venography after treatment. All 42 patients had successful recanalization of CVOs facilitated by the RF wire technique. There was one complication, which was not directly related to the RF wire: one case of cardiac tamponade attributed to balloon angioplasty after stent placement. Forty of 42 patients (95.2%) had patent stents and were asymptomatic at 6 and 9 months after treatment. The present results suggest that the RF wire technique is a safe and efficient alternative in the recanalization of symptomatic and chronic CVOs when conventional endovascular techniques have failed. Copyright © 2012 SIR. Published by Elsevier Inc. All rights reserved.
Hou, Xuwei; Jiang, Yu; Wang, Ningfu; Shen, Yun; Wang, Xiaoyan; Zhong, Yigang; Xu, Peng; Zhou, Liang
2015-01-01
Abstract The role of diagonal ear lobe crease (DELC) in coronary artery disease (CAD) diagnosis and prognosis remains controversial. In this study, we aimed to assess the combined effect of DELC with other conventional risk factors in the diagnosis and prognosis of CAD in Chinese patients who underwent angiography and coronary stent implantation. The study consisted of 956 consecutive patients who underwent angiography. The DELC was identified as no DELC, unilateral, and bilateral DELC. The conventional risk factors for CAD were recorded. Our dada showed that the overall presence of DELC is associated with CAD risk. Stratification analyses revealed that the diagnostic value of DELC was mostly significant in those with >4 risk factors. Also in patients with >4 risk factors, the presence of bilateral DELC remains to be associated with higher hs-CRP level, higher severity of CAD, and higher possibility of developing major adverse cardiac events after successful percutaneous coronary intervention (PCI). Our study confirmed the relation of DELC with CAD in Chinese patients; more importantly, our data suggest the combination of DELC and CAD risk factors will help to predict the incidence of CAD and may predict the prognosis after successfully PCI. PMID:26131833
Esparaz, Anthony M; Ahmed, Muneeb
2017-07-01
Local and systemic reactions to implanted metallic devices, particularly to those containing nickel, are well documented. Metal ions are released due to exposure of the metal to blood, proteins, other body fluids, and sheer mechanical stress. Metal ions then complex with native proteins and become antigens, which can elicit hypersensitivity reactions. Another case report depicts a specific allergic complication (early stent occlusion) related to metallic biliary stent implantation. We present a case of allergic symptoms, associated with eating, in a patient who developed nickel sensitivity after biliary metal stent placement confirmed by allergic skin testing to the same metallic biliary stent placed one year earlier. Symptoms resolved following partial removal of the non-epithelialized portion of the biliary stent.
Tang, Y F; Han, L; Lu, F L; Song, Z G; Lang, X L; Zou, L J; Xu, Z Y
2016-07-01
To summarize the results and methods of left subclavian artery revascularization by stented trunk fenestration for acute Stanford type A aortic dissection. Clinical data of 67 patients (54 male and 13 female, mean age of (50±10) years) underwent surgical treatment of left subclavian artery fenestration for acute Stanford A aortic dissection in Department of Cardiothoracic Surgery, Changhai Hospital, Second Military Medical College between September 2008 and December 2014 were analyzed retrospectively. The origin of the left subclavian artery was in the true lumen and no dissection existed near the artery's starting. There were 18 cases of Marfan's syndrome. Preoperative echocardiography showed moderate to severe aortic regurgitation in 10 cases, and mitral regurgitation in 3 cases. Electrocardiogram showed myocardial ischemia in 5 cases. Three patients had acute impaired renal function. All the patients received total arch replacement combined with stented elephant trunk implantation. Left subclavian artery revascularization was performed by stented trunk fenestration as follows: firstly, stented elephant trunk was implanted to completely cover the left subclavian artery, then part of stented trunk's polyester lining was removed which is located at the origin of left subclavian artery. Aortic root procedures included aortic valve replacement in 2 cases, Bentall procedure in 21 cases and aortic valve sparing in 44 cases. Three patients received mitral valve repair and 6 patients received coronary artery bypass grafting. The cardiopulmonary bypass time, cross-clamp time, and circulatory arrest time were (179±32) minutes, (112±25) minutes, and (26±10) minutes, respectively. The in-hospital mortality was 7.5% (5/67): 2 patients died of multiple organ failure, 1 patient died of acute renal failure and another 2 patients died of severe infection shock. Two patients required reexploration for root bleeding. Transient neurology dysfunction developed in 6 patients. Six patients received tracheotomy and prolonged ventilation due to pulmonary infection. All patients discharged from the hospital were followed up for 1 to 5 years. During long-term follow-up, the survival rate was 100% and 89.8% at 1 and 5 years, respectively. CT angiography was performed once per year after discharged. The left subclavian artery perfusion was good. No dissection or anastomosis leakage was identified in any case. Stroke and left limb ischemia did not develope. For acute Stanford type A aortic dissection whose origin of the left subclavian artery is in the true lumen and no dissection existed near the artery's starting, the left subclavian artery revascularization by stented trunk fenestration technique during total arch replacement combined with stented elephant trunk implantation is reliable and effective.
Wilmes, E; Berger, H; Dienemann, H; Jolk, A
1994-01-01
The treatment of tracheal stenoses caused by tracheomalacia is mainly carried out by means of sleeve resection, tracheopexy with ring support or other tracheoplastic operative procedures. If patients cannot be treated by surgical operative strategies, conventional stents are usually used to dilate the trachea. The use of a self-expanding elastic metal prosthesis in 5 patients with tracheal airway obstruction caused by tracheomalacia proved to be a true alternative in the therapy of tracheobronchial stenoses. We report on the long term use of 5 patients with tracheal stenoses treated by implantation of elastic metal wallstents. The implantation of the stents resulted in immediate improvement in respiratory function in all 5 patients. None of the patients experienced complications secondary to the stent placement. The stents were well tolerated (long-time follow-up 26 months). The implantation of self-expanding metal stents type "wallstent" seems to offer alternative possibilities for the treatment of tracheomalacia.
Transhepatic implant of a trimmed Melody™ valved stent in tricuspid position in a 1-year-old infant.
Cools, Bjorn; Rega, Filip; Gewillig, Marc
2017-02-15
Percutaneous valved stent implantation is precluded in small infants because large delivery sheaths and large devices. We describe a procedure in a 1-year-old boy in whom a 19 mm Epic™ valve in tricuspid position had become dysfunctional. As the internal diameter of the prosthetic valve was about 16 mm, the only available valve was the Melody™ valved stent. Technical modifications were required to address issues like venous access, the bulky delivery system, and the length of the valved stent. The Melody™ valved stent was surgically trimmed and mounted on a 16 mm Tyshak balloon, access was provided transhepatically through a short 18 Fr sheath. After deployment, the intrahepatic route was sealed with two vascular plugs (8 and 10 mm) in tandem. The procedure was uncomplicated with perfect valve function 18 months after implant. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Yang, Hongtao; Wang, Cong; Liu, Chaoqiang; Chen, Houwen; Wu, Yifan; Han, Jintao; Jia, Zichang; Lin, Wenjiao; Zhang, Deyuan; Li, Wenting; Yuan, Wei; Guo, Hui; Li, Huafang; Yang, Guangxin; Kong, Deling; Zhu, Donghui; Takashima, Kazuki; Ruan, Liqun; Nie, Jianfeng; Li, Xuan; Zheng, Yufeng
2017-11-01
In the present study, pure zinc stents were implanted into the abdominal aorta of rabbits for 12 months. Multiscale analysis including micro-CT, scanning electron microscopy (SEM), scanning transmission electron microscopy (STEM) and histological stainings was performed to reveal the fundamental degradation mechanism of the pure zinc stent and its biocompatibility. The pure zinc stent was able to maintain mechanical integrity for 6 months and degraded 41.75 ± 29.72% of stent volume after 12 months implantation. No severe inflammation, platelet aggregation, thrombosis formation or obvious intimal hyperplasia was observed at all time points after implantation. The degradation of the zinc stent played a beneficial role in the artery remodeling and healing process. The evolution of the degradation mechanism of pure zinc stents with time was revealed as follows: Before endothelialization, dynamic blood flow dominated the degradation of pure zinc stent, creating a uniform corrosion mode; After endothelialization, the degradation of pure zinc stent depended on the diffusion of water molecules, hydrophilic solutes and ions which led to localized corrosion. Zinc phosphate generated in blood flow transformed into zinc oxide and small amounts of calcium phosphate during the conversion of degradation microenvironment. The favorable physiological degradation behavior makes zinc a promising candidate for future stent applications. Copyright © 2017 Elsevier Ltd. All rights reserved.
Wang, Lixiu; Bi, Yayan; Cao, Muhua; Ma, Ruishuang; Wu, Xiaoming; Zhang, Yan; Ding, Wenbo; Liu, Yan; Yu, Qian; Zhang, Yingqian; Jiang, Hua; Sun, Yingchun; Tong, Dongxia; Guo, Li; Dong, Zengxiang; Tian, Ye; Kou, Junjie; Shi, Jialan
2016-11-15
Relatively little is known about the role of phosphatidylserine (PS) in procoagulant activity (PCA) in patients with non-ST-elevated myocardial infarction (NSTEMI) after stent implantation. This study was designed to evaluate whether exposed PS on microparticles (MPs) and blood cells were involved in the hypercoagulable state in NSTEMI patients with stent implantation. NSTEMI patients (n=90) and healthy controls (n=20) were included in our study. PS exposure on MPs and blood cells was analyzed with flow cytometer and confocal microscope. PCA was evaluated by clotting time, purified coagulation complex assays and fibrin production assays. Baseline levels of MPs and PS + blood cells were significantly higher (P<0.001) in the patients than in controls. After stent implantation, a remarkable increase was observed in both MPs and PS + blood cells. Specifically, PS + MPs, PS + platelets and erythrocytes peaked at 18h following stent implantation, while PS + leukocytes peaked on day 2. In addition, circulating MPs (mostly derived from platelets, leukocytes, erythrocytes and endothelial cells) cooperating with PS + blood cells, contributed to markedly shortened coagulation time and markedly increased FXa/thrombin/fibrin (all P<0.01) generation in patient group. Moreover, blockade of exposed PS on MPs and cells with lactadherin inhibited PCA by approximately 70%. Our results suggest that PS + MPs and blood cells play a procoagulant role in NSTEMI patients following stent implantation. Blockade of PS could become a novel therapeutic modality for the prevention of thrombosis in these patients. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Hou, Dongming; Narciso, Hugh; Kamdar, Kirti; Zhang, Ping; Barclay, Bruce; March, Keith L
2005-01-01
The effects of nitric acid (NO) on vessel response to injury include the inhibition of platelet adhesion, platelet aggregation, leukocyte adhesion and smooth muscle cell proliferation. Releasing NO from a stent might reduce the clinical problem of restenosis. The present study was designed to examine whether an NO-eluting covered stent can prevent neointimal formation in a porcine carotid overstretch injury model. The interior of a self-expanding polytetrafluoroethylene (ePTFE)-covered aSpire stent was coated with silicone, which contained 23.6 microg or 54.5 microg sodium nitroprusside (SNP, NO-releasing compound). The stent was implanted into carotid artery. Six pigs were implanted with stents, one high-dose SNP and one uncoated control, following balloon overstretch injury of the carotid artery with a balloon-to-artery ratio of 1.3:1. No local or systemic toxicity was evidenced in the six pigs after carotid artery implantation with either low- or high-dose stents within a week. At day 28, the mean intimal thickness was 0.12 +/- 0.05 mm for NO-eluting stents and 0.43 +/- 0.09 mm for uncoated stents (p = 0.008). The mean neointimal area was reduced from 2.40 +/- 0.39 mm2 for control stents to 0.49 +/- 0.16 mm2 for NO-eluting stents (p < 0.0001), which resulted in a 24% reduction of angiographic vessel narrowing. The NO-eluting ePTFE-covered stent is feasible and effectively reduces in-stent neointimal hyperplasia at 28 days in a porcine carotid overstretch model.
Double Y-stenting for tracheobronchial stenosis.
Oki, Masahide; Saka, Hideo
2012-12-01
The purpose of the present study was to evaluate the feasibility, efficacy and safety of the double Y-stenting technique, by which silicone Y-stents are placed on both the main carina and another peripheral carina, for patients with tracheobronchial stenosis. Under general anaesthesia, using rigid and flexible bronchoscopes, a Dumon™ Y-stent (Novatech, La Ciotat, France) was first placed on the primary right or secondary left carina followed by another Y-stent on the main carina so as to insert the bronchial limb of the stent into the first Y-stent. Patients who underwent double Y-stent placement during 3 yrs and 1 month in a single centre were retrospectively reviewed. In the study period, 93 patients underwent silicone stent placement and 12 (13%) underwent double Y-stent placement (11 for right and one for left bronchus). A combination of Y-stents, 14 × 10 × 10 mm and 16 × 13 × 13 mm in outer diameter, were most frequently used. Dyspnoea was relieved in all patients. Six out of seven patients with supplemental oxygen before stent placement could be discharged without supplemental oxygen. Median survival after stenting was 94.5 days. One pneumothorax and one granuloma formation occurred. Double Y-stent placement for patients with tracheobronchial stenosis was technically feasible, effective and acceptably safe.
2012-01-01
Background Refractory benign esophageal strictures (RBESs) have been treated with the temporary placement of different self-expanding stents with conflicting results. We compared the clinical effectiveness of 3 types of stents: self-expanding plastic stents (SEPSs), biodegradable stents, and fully covered self-expanding metal stents (FCSEMSs), for the treatment of RBES. Methods This study prospectively evaluated 3 groups of 30 consecutive patients with RBESs who underwent temporary placement of either SEPSs (12 weeks, n = 10), biodegradable stents (n = 10) or FCSEMSs (12 weeks, n = 10). Data were collected to analyze the technical success and clinical outcome of the stents as evaluated by recurrent dysphagia, complications and reinterventions. Results Stent implantation was technically successful in all patients. Migration occurred in 11 patients: 6 (60%) in the SEPS group, 2 (20%) in the biodegradable group and 3 (30%) in the FCSEMS group (P = 0.16). A total of 8/30 patients (26.6%) were dysphagia-free after the end of follow-up: 1 (10%) in the SEPS group, 3 (30%) in the biodegradable group and 4 (40%) in the FCSEMS group (P = 0.27). More reinterventions were required in the SEPS group (n = 24) than in the biodegradable group (n = 13) or the FCSEMS group (n = 13) (P = 0.24). Multivariate analysis showed that stricture length was significantly associated with higher recurrence rates after temporary stent placement (HR = 1.37; 95% CI = 1.08-1.75; P = 0.011). Conclusions Temporary placement of a biodegradable stent or of a FCSEMS in patients with RBES may lead to long-term relief of dysphagia in 30 and 40% of patients, respectively. The use of SEPSs seems least preferable, as they are associated with frequent stent migration, more reinterventions and few cases of long-term improvement. Additionally, longer strictures were associated with a higher risk of recurrence. PMID:22691296
2016-01-01
Purpose The aim of this study was to clinically assess the impact of a prefabricated implant-retained stent clipped over healing abutments on the preservation of keratinized mucosa around implants after implant surgery, and to compare it with horizontal external mattress sutures. Methods A total of 50 patients were enrolled in this study. In the test group, a prefabricated implant-retained stent was clipped on the healing abutment after implant surgery to replace the keratinized tissue bucco-apically. In the control group, horizontal external mattress sutures were applied instead of using a stent. After the surgical procedure, the width of the buccal keratinized mucosa was measured at the mesial, middle, and distal aspects of the healing abutment. The change in the width of the buccal keratinized mucosa was assessed at 1 and 3 months. Results Healing was uneventful in both groups. The difference of width between baseline and 1 month was −0.26±0.85 mm in the test group, without any statistical significance (P=0.137). Meanwhile, the corresponding difference in the control group was −0.74±0.73 mm and it showed statistical significance (P<0.001). The difference of width between baseline and 3 months was −0.57±0.97 mm in the test group and −0.86±0.71 mm in the control group. These reductions were statistically significant (P<0.05); however, there was no difference between the 2 groups. Conclusions Using a prefabricated implant-retained stent was shown to be effective in the preservation of the keratinized mucosa around implants and it was simple and straightforward in comparison to the horizontal external mattress suture technique. PMID:27800215
Mitra, V; Hu, M; Majumdar, D; Krishnan, V; Chaudhury, B; Hancock, J; Dwarakanath, D
2017-03-01
Self-expandable metal stents are often used to treat obstructive large bowel cancers. This study assessed the safety and efficacy of colonic stent insertion carried out in a district general hospital. Methods A retrospective review was carried out between 1 January 2007 and 28 February 2014 to identify patients who underwent stent insertion for malignant colorectal obstruction. Results Seventy-five patients (median age 75.2 years, 70.6% male) with primary colorectal cancer underwent stent insertion - 53 underwent semi-elective self-expanded metal stent insertion (for subacute bowel obstruction) and 22 had emergency stent inserted (for acute bowel obstruction). The majority (88%) had self-expanded metal stents inserted for palliation. Technical and clinical success rates were 98.7% and 91.2%, respectively. One patient had stent-related perforation; there was no procedure-related mortality. Conclusion This study shows that self-expanded metal stent insertion in malignant colorectal obstruction is safe and effective and can be successfully delivered in a district general hospital with high technical and clinical success rates.
A review on biodegradable materials for cardiovascular stent application
NASA Astrophysics Data System (ADS)
Hou, Li-Da; Li, Zhen; Pan, Yu; Sabir, MuhammadIqbal; Zheng, Yu-Feng; Li, Li
2016-09-01
A stent is a medical device designed to serve as a temporary or permanent internal scaffold to maintain or increase the lumen of a body conduit. The researchers and engineers diverted to investigate biodegradable materials due to the limitation of metallic materials in stent application such as stent restenosis which requires prolonged anti platelet therapy, often result in smaller lumen after implantation and obstruct re-stenting treatments. Biomedical implants with temporary function for the vascular intervention are extensively studied in recent years. The rationale for biodegradable stent is to provide the support for the vessel in predicted period of time and then degrading into biocompatible constituent. The degradation of stent makes the re-stenting possible after several months and also ameliorates the vessel wall quality. The present article focuses on the biodegradable materials for the cardiovascular stent. The objective of this review is to describe the possible biodegradable materials for stent and their properties such as design criteria, degradation behavior, drawbacks and advantages with their recent clinical and preclinical trials.
Double Lumen Polyamide Tube-stent for the Treatment of Recurrent Postcorrosive Esophageal Stenosis.
Woynarowski, Marek; Dądalski, Maciej; Wojno, Violetta; Teisseyre, Mikołaj; Hurkała, Leszek; Płowiecki, Emil
2017-05-01
This article presents the results of endoscopic treatment for recurrent postcorrosive esophageal stenosis with a tube-stent developed at our institution. The tube-stent was implanted in 5 children with corrosive esophageal injury at the age of 2 to 8.5 years after 7 to 64 dilatation sessions during 5 to 118 months. In total, 13 tube-stents were implanted. One patient had undergone 9 procedures during 2.5 years and the tube-stent remained in place for 14 to 250 days. This patient was tube-stent-dependent due to the lack of any possibility of surgical reconstruction. Two patients had the tube-stent removed after 150 to 205 days and they remain free from esophageal restenosis. One patient did not tolerate the tube-stent, evacuated it after 1 day and was referred for surgical esophagus replacement. One patient is currently still being treated with the tube-stent. Tube-stent was well tolerated and it may be effective in children with recurrent critical postcorrosive esophageal stenosis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cerna, Marie; Koecher, Martin, E-mail: martin.kocher@seznam.cz; Valek, Vlastimil
2011-12-15
Purpose: This study was designed to evaluate our experience with the treatment of postoperative anastomotic leaks and benign esophageal perforations with covered biodegradable stents. Materials and Methods: From 2008 to 2010, we treated five men with either an anastomotic leak or benign esophageal perforation by implanting of covered biodegradable Ella-BD stents. The average age of the patients was 60 (range, 38-74) years. Postoperative anastomotic leaks were treated in four patients (1 after esophagectomy, 1 after resection of diverticulum, 2 after gastrectomy). In one patient, perforation occurred as a complication of the treatment of an esophageal rupture (which occurred during amore » balloon dilatation of benign stenosis) with a metallic stent. Results: Seven covered biodegradable stents were implanted in five patients. Primary technical success was 100%. Clinical success (leak sealing) was achieved in four of the five patients (80%). Stent migration occurred in three patients. In two of these patients, the leak had been sealed by the time of stent migration, therefore no reintervention was necessary. In one patient an additional stent had to be implanted. Conclusion: The use of biodegradable covered stents for the treatment of anastomotic leaks or esophageal perforations is technically feasible and safe. The initial results are promising; however, larger number of patients will be required to evaluate the capability of these biodegradable stents in the future. The use of biodegradable material for coverage of the stent is essential.« less
An argument for the use of multiple segment stents in curved arteries.
Kasiri, Saeid; Kelly, Daniel J
2011-08-01
Stenting of curved arteries is generally perceived to be more challenging than straight vessels. Conceptually implanting multiple shorter stents rather than a single longer stent into such a curved artery represents a promising concept, but little is known about the impact of such an approach. The objective of this study is to evaluate the effectiveness of using a multiple segment stent rather than a single long stent to dilate a curved artery using the finite element method. A double segment stent (DSS) and a single segment stent (SSS) were modeled. The stents were compared when expanded into a model of a curved artery. The model predicts that the DSS provides higher flexibility, more conformity, and lower recoil in comparison to the SSS. The volume of arterial tissue experiencing high levels of stress due to stent implantation is also reduced for the DSS. It is suggested that a multiple segment stenting system is a potential solution to the problem of higher rates of in-stent restenosis in curved arteries and mechanically challenging environments.
Covered Stent and Coils Embolization of a Pulmonary Artery Pseudoaneurysm After Gunshot Wound
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huet, Nicolas, E-mail: nhuet@chu-grenoble.fr; Rodiere, Mathieu, E-mail: mrodiere@chu-grenoble.fr; Badet, Michel, E-mail: michel.badet@ch-chambery.fr
We report the first case of endovascular covered stent implantation for the treatment of a large pulmonary artery pseudoaneurysm (PAPA) following a right thoracic gunshot wound. After resuscitation and hemodynamic stabilization, a CT angiography was performed to analyze the neck size of the PAPA and its position relative to the branches of the parent artery. Covered stent implantation with additional coil embolization was successfully performed. At the 4-year follow-up, the stents remained patent and there was neither pseudoaneurysm recurrence nor treatment-related complication.
Samimi, David B; Ediriwickrema, Lilangi S; Bielory, Brett P; Miller, Darlene; Lee, Wendy; Johnson, Thomas E
To investigate the pathogens and biofilms responsible for clinically significant infection of silicone stents implanted within the lacrimal system. Retrospective review of culture results and patient demographics for all silicone lacrimal stents removed early for clinically significant infection and sent to the Bascom Palmer Microbiology Laboratory through the end of year 2010. As a control, routinely removed, clinically noninfected stents from the same institution were prospectively sent for culture over a 6-month period. Four clinically infected and 6 clinically noninfected stents showing mucus within the lumen at removal were sent for scanning electron microscopy. Images were randomized and graded by a microbiologist for the presence of organisms, matrix deposits, organisms within matrix, and overall impression of significant biofilm formation. Nineteen stents were included in the study; 100% of clinically infected (n = 10) and noninfected (n = 9) stents were culture positive. Culture positivity for nontuberculous mycobacterium was found in 90% of infected stents and none of the noninfected stents (p < 0.001). Of infected stents, 50% grew Gram-positive organisms compared with 89% of noninfected stents (p = 0.07). Fifty percent of infected versus 67% of noninfected stents were culture positive for Gram-negative organisms (p = 0.46). Electron microscopy of stents revealed organisms consistent with culture results (size, shape) in planktonic and biofilm form. Masked observer image grading revealed a statistically significant higher amount of organism and biofilm on infected versus noninfected specimen. Nontuberculous mycobacteria comprise the primary pathogens responsible for clinically significant infection of silicone stents in the lacrimal system in South Florida. Robust biofilm production by this organism likely plays a role in pathogenesis. Further research into biofilm-related lacrimal implant infection may aid in the development of useful prevention and treatment strategies.
Early outcomes of carotid artery stenting.
Akar Bayram, N; Bozkurt, E; Ayhan, H; Gürkaş, E; Orhan, G; Ak, F; Bilen, E; Sari, C; Akçay, M; Durmaz, T; Keles, T
2012-03-01
Ischemic cerebrovascular events are the most common reason for patients to be bedridden and the third most common reason for death. Many studies in recent years have demonstrated that carotid artery stenting (CAS) may be an alternative to carotid endarterectomy (CEA). In this study, we aimed to report early outcomes of patients who were treated with CAS in our clinic and discuss practicability, advantages and safety of CAS. Eighty patients who underwent CAS between December 2009 and May 2011 were eligible. The mean age was 65 years (range, 49 - 89 years). Of the study group, 73.75% were males and 26.25% were female. The percentage of asymptomatic patients was 11.7%, and the remaining patients were symptomatic. A distal embolic protection device (Angioguard®) was used in 22% of the patients whereas, in the other patients (78%), a proximal blockage system (Mo.MA®) was used. Self-expandable hybrid stents were implanted in all patients and post-dilatation was performed after implantation. None of the patients suffered from stroke, myocardial infarction or death due to CAS during their hospital stay. The mean follow-up period was 10 months (range 2 - 18 months) after discharge. None of the patients had died or had a stroke, a transient ischemic attack (TIA), or a myocardial infarction during the follow-up period. Re-stenosis was not observed in the follow-up carotid Doppler ultrasonography; flow rates were within normal limits. No major complication was observed during the early follow-up period in patients who underwent CAS in our clinic. Only 2 (2.5%) patients showed transient numbness and weakness and these did not lead to morbidity. In the management guide of extracranial carotid and vertebral artery diseases, CAS, in the light of recent studies, is recommended as an alternative to CEA in recommendations for revascularization. One of the important issues emphasized in this guide is the experience of centers. Very low complication rates after CAS suggested that, with suitable patient selection and an experienced team, similar results may be obtained.
Park, Ji Yeon; Shin, Ji Hoon; Song, Ho-Young; Yi, Seong Yoon; Kim, Jin Hyoung
2012-02-01
The purpose of this study was to evaluate the characteristics of airway complications and survival with special reference to radiation therapy in the care of patients undergoing covered stent placement for malignant esophageal strictures. A total of 208 patients who underwent stent placement with or without palliative radiation therapy for inoperable esophageal cancer were included. The endpoints were frequency, type, and management of airway complications; association between occurrence of airway complications and radiation therapy history; and differences in stent-to-complication interval and survival period after esophageal stenting between patients who underwent radiation therapy before and those who underwent radiation therapy after stent placement. Airway complications occurred in 23 patients (11.1%): 18 (78.3%) had esophagorespiratory fistula, three (13.0%) had airway narrowing, and two (8.7%) had both complications. The frequency of airway complications was significantly greater among patients who underwent RT than those who did not (p = 0.005) but was not significantly different between the radiation before stenting and radiation after stenting groups (p = 0.158). The median stent-to-complication interval and survival period after esophageal stenting were significantly shorter in the radiation before stenting group than in the radiation after stenting group (p = 0.002, p = 0.001). Esophagorespiratory fistula is much more common than airway narrowing as an airway complication. The rate of complications increases significantly in association with radiation therapy among patients with malignant esophageal stricture. Clinicians need to be aware of earlier airway complications and poorer prognosis among patients who undergo radiation therapy before placement of an esophageal stent than in patients who undergo radiation after stent placement.
Fully covered self-expandable metal stent in tracheobronchial disorders: clinical experience.
Marchese, Roberto; Poidomani, Grazia; Paglino, Giuseppe; Crimi, Claudia; Lo Nigro, Chiara; Argano, Vincenzo
2015-01-01
The third-generation fully covered self-expandable metallic stent (SEMS) has been developed to solve the problems of difficult removal and in-stent granuloma formation related to the uncovered or partially covered type. There are few written reports about the performance of this type of stents with early encouraging results. To report and analyse our experience with the Silmet® stent in the management of malignant and benign tracheobronchial disorders. We retrospectively reviewed medical records of patients who underwent fully covered SEMS Silmet placement at the Interventional Pulmonology Unit, La Maddalena Cancer Center, Palermo, Italy, between May 2010 and August 2013. Stents were placed in 52 patients with malignant (n = 49) and benign airway obstruction (n = 2) and broncho-oesophageal fistula (n = 1). SEMSs were inserted into the trachea (n = 19), the main bronchi (n = 21) and the peripheral bronchi (n = 31). Besides 1 procedural dislocation, the deployment was successful in all patients with an immediate significant improvement of symptoms (Barthel Index p < 0.001; Medical Research Council score p < 0.001). A radiographic improvement was detected in 48% of patients. The mean follow-up duration was 119 ± 120 days (range 22-549 days). Complications observed were: migration (7.6%), tumour overgrowth (15%), infections (5.7%), granulation tissue formation (3.8%) and mucus plug (3.8%). The Silmet stent is effective, safe and simple to implant and remove. We suggest its use in cases of tight stenoses, in the treatment of small- to medium-caliber airways or in cases of tortuous airways. © 2015 S. Karger AG, Basel.
Ronald, James; Davis, Bradley; Guevara, Carlos J; Pabon-Ramos, Waleska M; Smith, Tony P; Kim, Charles Y
2017-05-15
To report patency rates for stent deployment for treatment of in-stent stenosis of the central veins of the chest in hemodialysis patients. A retrospective analysis was performed on 29 patients who underwent 35 secondary percutaneous transluminal stent (PTS) deployments for in-stent stenosis within the central veins that were refractory to angioplasty and ipsilateral to a functioning hemodialysis access (in-stent PTS group). For comparison, patency data were acquired for 47 patients who underwent 78 successful percutaneous transluminal angioplasty (PTA) procedures for in-stent stenosis (in-stent PTA group) and 55 patients who underwent 55 stent deployments within native central vein stenosis refractory to angioplasty (native vein PTS group). The 3-, 6-, and 12-month primary lesion patency for the in-stent PTS group was 73%, 57%, and 32%, respectively. The 3-, 6-, and 12-month primary patency for the in-stent PTA group was 70%, 38%, and 17% and for the native vein PTS group was 78%, 57%, and 26%, which were similar to the in-stent PTS group (p = 0.20 and 0.41, respectively). The 3-, 6-, and 12-month secondary access patency was 91%, 73%, and 65% for the in-stent PTS group. Sub-analysis of the in-stent PTS group revealed no difference in primary (p = 0.93) or secondary patency rates (p = 0.27) of bare metal stents (n = 23) compared with stent grafts (n = 12). Stent deployment for central vein in-stent stenosis refractory to angioplasty was associated with reasonable patency rates, which were similar to in-stent PTA and native vein PTS.
NASA Astrophysics Data System (ADS)
Wang, Hujun; Liu, Jinghua; Zheng, Xu; Rong, Xiaohui; Zheng, Xuwei; Peng, Hongyu; Silber-Li, Zhanghua; Li, Mujun; Liu, Liyu
2015-06-01
Percutaneous coronary intervention (PCI), especially coronary stent implantation, has been shown to be an effective treatment for coronary artery disease. However, in-stent restenosis is one of the longstanding unsolvable problems following PCI. Although stents implanted inside narrowed vessels recover normal flux of blood flows, they instantaneously change the wall shear stress (WSS) distribution on the vessel surface. Improper stent implantation positions bring high possibilities of restenosis as it enlarges the low WSS regions and subsequently stimulates more epithelial cell outgrowth on vessel walls. To optimize the stent position for lowering the risk of restenosis, we successfully established a digital three-dimensional (3-D) model based on a real clinical coronary artery and analysed the optimal stenting strategies by computational simulation. Via microfabrication and 3-D printing technology, the digital model was also converted into in vitro microfluidic models with 3-D micro channels. Simultaneously, physicians placed real stents inside them; i.e., they performed “virtual surgeries”. The hydrodynamic experimental results showed that the microfluidic models highly inosculated the simulations. Therefore, our study not only demonstrated that the half-cross stenting strategy could maximally reduce restenosis risks but also indicated that 3-D printing combined with clinical image reconstruction is a promising method for future angiocardiopathy research.
A repositionable valved stent for endovascular treatment of deteriorated bioprostheses.
Zegdi, Rachid; Khabbaz, Ziad; Borenstein, Nicolas; Fabiani, Jean-Noël
2006-10-03
We report our animal experience of endovascular valve replacement (VR) of failed bioprosthesis (BP) using an original delivery catheter allowing repositioning of the valved stent (VS). Among the different devices designed for percutaneous VR, none has the potential for repositioning of a fully deployed VS. Five sheep underwent, on beating heart, tricuspid VR with a stented BP. Prolapse of 1 leaflet was induced by tearing. For the endovascular tricuspid VR, we used a VS constructed with a nitinol self-expandable stent and a porcine stentless aortic valve. We also used an original delivery catheter, allowing repositioning of the VS through a compression or relaxation mechanism of the stent. Epicardial echocardiography and right ventriculography showed severe tricuspid regurgitation, with a regurgitant jet extending to the inferior vena cava. After surgical exposure to the infrarenal inferior vena cava, the VS was successfully implanted inside the failed BP in all cases. Repositioning of the fully deployed VS was always possible. Echocardiographic and macroscopic studies revealed adequate VS positioning, excellent leaflet opening, and absence of any intraprosthetic or periprosthetic leak. Endovascular VR was easily performed in sheep with failed BP in the tricuspid position. The novel delivery catheter allowed adequate repositioning of our fully deployed VS before its definitive release. One may anticipate that the safety improvement conferred by this new technology will certainly favor the development of percutaneous VR in clinical practice.
Wang, Geng; Sun, Zhongwei; Jin, Quanmin; Xu, Kai; Li, Yi; Wang, Xiaozeng; Ma, Yingyan; Liu, Haiwei; Zhao, Xin; Wang, Bin; Deng, Jie; Guan, Shaoyi; Ge, Meiling; Wang, Xiaoyan; Xu, Bo; Han, Yaling
2015-03-01
To evaluate the preliminary safety and efficacy of the EXCEL II stent system. Although the first biodegradable polymer drug-eluting stent (BP-DES), EXCEL, was launched nearly a decade ago, in-stent restenosis and stent thrombosis remain pertinent clinical problems in practice. A new cobalt-chromium BP-DES EXCEL II has been developed with the aim of improving stent safety and efficacy. Forty-five patients with single de novo native coronary lesions were enrolled and randomized to two groups in a 2:1 ratio, the 4-month follow-up group (n = 30) and the 12-month follow-up group (n = 15). All patients underwent percutaneous coronary intervention (PCI) with the EXCEL II stent system. Quantitative coronary angiography (QCA) and optical coherence tomography (OCT) were used to assess coronary vasculature at the designated 4- or 12-month follow-up. The primary outcome was major adverse cardiac events (MACE) at 30 days post-PCI. No MACE, thrombotic events, or target lesion failure was found in the 45 patients during the 12-month follow-up. There was no significant difference (P > 0.05) between the two groups in terms of in-stent and in-segment late lumen loss (LLL). No in-stent and in-segment restenosis was found in either group. At follow-up, the ratio of >10% uncovered struts per lesion was 26.67% in the 4-month group and 0% in the 12-month group (P < 0.05). Neointimal coverage in the 12-month group was significantly better than in the 4-month group (98.58% vs. 93.51%, P < 0.01). This first-in-man study demonstrates promising feasibility, safety, and efficacy of EXCEL II stents. These stents were found to have rapid endothelialization and low LLL rates at 4 and 12 months after implantation. © 2015 Wiley Periodicals, Inc.
iStent trabecular micro-bypass stent for open-angle glaucoma
Le, Kim; Saheb, Hady
2014-01-01
Trabecular micro-bypass stents, commonly known as iStents, are micro-invasive glaucoma surgery (MIGS) devices used to treat open-angle glaucoma. Like other MIGS procedures that enhance trabecular outflow, the iStent lowers intraocular pressure (IOP) by creating a direct channel between the anterior chamber and Schlemm’s canal. iStents are typically implanted at the time of phacoemulsification for patients with open-angle glaucoma and visually significant cataracts. This review summarizes the published data regarding the efficacy, safety, and cost considerations of trabecular micro-bypass stents. Most studies found statistically significant reductions in mean IOP and ocular medication use after combined phacoemulsification with single or double iStent implantation. The devices were found to be very safe, with a safety profile similar to that of cataract surgery. Complications were infrequent, with the most common complications being temporary stent obstruction or malposition, which resolved with observation or secondary procedures. Future studies are needed to evaluate long-term outcomes, patient satisfaction, cost effectiveness, and expanded indications. PMID:25284980
Geraghty, Patrick J; Mewissen, Mark W; Jaff, Michael R; Ansel, Gary M
2013-08-01
The predominant mode of bare nitinol stent failure is diffuse in-stent restenosis, and failure rates correlate to the length and complexity of the treated lesion. Addition of an expanded polytetrafluoroethylene lining to a nitinol stent frame, as found in the VIABAHN endoprosthesis, mitigates the ingrowth of intimal hyperplasia. We compared the long-term outcomes of complex superficial femoral artery disease intervention using the VIABAHN endoprosthesis to those obtained with bare nitinol stent implantation. One hundred forty-eight patients with symptomatic complex superficial femoral artery disease (TransAtlantic Inter-Society Consensus I class C and D lesions, accompanied by intermittent claudication or ischemic rest pain) were randomized to endovascular intervention using either bare nitinol stent implantation (76 patients) or nonheparin-bonded VIABAHN endoprosthesis deployment (72 patients). Patency, limb hemodynamics, and quality of life were evaluated at 1, 6, 12, 24, and 36 months following intervention. The average treated lesion measured 18 ± 8 cm in length, and 58.8% of lesions displayed segmental or complete occlusion. At 3 years, primary patency rates (defined by peak systolic velocity ratio ≤ 2.0 and no target lesion revascularization) did not significantly differ between patients treated with the VIABAHN stent graft and those who received a bare nitinol stent (24.2% vs 25.9%; P = .392). Stent fractures were significantly more common in bare nitinol stents (50.0%) than in the VIABAHN endoprostheses (2.6%). Primary-assisted patency rates were higher in those receiving bare nitinol stents than the VIABAHN stent graft (88.8% vs 69.8%; P = .04), although secondary patency rates did not differ between bare nitinol stent and stent graft recipients (89.3% vs 79.5%; P = .304). There were no instances of procedure-related mortality or amputation. The hemodynamic improvement and quality measures improved equally in both groups. The long-term outcomes of complex superficial femoral artery disease intervention using the VIABAHN endograft and bare nitinol stents are similar. Although primary patency rates are low in both study arms, excellent primary-assisted and secondary patency rates were achieved, with sustained augmentation of limb perfusion and quality-of-life measures. Patency rates diminish most rapidly in the first year after device implantation. Copyright © 2013 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.
Malvankar-Mehta, Monali S.; Iordanous, Yiannis; Chen, Yufeng Nancy; Wang, Wan Wendy; Patel, Sangita Shantilal; Costella, John; Hutnik, Cindy M. L.
2015-01-01
Background Minimally invasive glaucoma surgeries (MIGS) have attracted significant attention, as they have been reported to lower intra-ocular pressure (IOP) and have an excellent safety profile. The iStent is an example of a minimally invasive glaucoma device that has received particular attention due to its early and wide spread utilization. There is a growing body of evidence supporting its use at the time of phacoemulsification to help lower IOP. However, it is still not clear how much of the IOP lowering effect can be attributed to the iStent, the crystalline lens extraction or both when inserted concurrently at the time of phacoemulsification. This has been an important issue in understanding its potential role in the glaucoma management paradigm. Purpose To conduct a systematic review and meta-analysis comparing the IOP lowering effect of iStent insertion at the time of phacoemulsification versus phacoemulsification alone for patients with glaucoma and cataracts. Methods A systematic review was conducted utilizing various databases. Studies examining the IOP lowering effect of iStent insertion in combination with phacoemulsification, as well as studies examining the IOP lowering effect of phacoemulsification alone were included. Thirty-seven studies, reporting on 2495 patients, met the inclusion criteria. The percentage reduction in IOP (IOPR%) and mean reduction in topical glaucoma medications after surgery were determined. The standardized mean difference (SMD) was computed as a measure of the treatment effect for continuous outcomes taking into account heterogeneity. Fixed-effect and random-effect models were applied. Results A 4% IOP reduction (IOPR%) from baseline occurred following phacoemulsification as a solo procedure compared to 9% following an iStent implant with phacoemulsification, and 27% following 2 iStents implants with phacoemulsification. Compared with cataract extraction alone, iStent with phacoemulsification resulted in significant reduction in the post-operative IOP (IOPR%) (SMD = -0.46, 95% CI: [-0.87, -0.06]). A weighted mean reduction in the number of glaucoma medications per patient was 1.01 following phacoemulsification alone compared to 1.33 after one iStent implant with phacoemulsification, and 1.1 after 2 iStent implants with phacoemulsification. Compared to cataract extraction alone, iStent with cataract extraction showed a significant decrease in the number of glaucoma medications (SMD = -0.65, 95% CI: [-1.18, -0.12]). Funnel plots suggested the absence of publication bias. Conclusion Both iStent implantation with concurrent phacoemulsification and phacoemulsification alone result in a significant decrease in IOP and topical glaucoma medications. In terms of both reductions, iStent with phacoemulsification significantly outperforms phacoemulsification alone. PMID:26147908
Kostecki, Jacek; Zaniewski, Maciej; Ziaja, Krzysztof; Urbanek, Tomasz; Kuczmik, Waclaw; Krzystanek, Ewa; Ziaja, Damian; Korzeniowski, Tomasz; Majewski, Eugeniusz; Hartel, Marcin; Swiat, Maciej; Sioma-Markowska, Urszula
2011-01-01
In this study, the mid-term results (6 month follow-up) of the endovascular treatment in patients with Chronic Cerebro-Spinal Venous Insufficiency (CCSVI) and multiple sclerosis (MS) were prospectively evaluated. Thirty-six patients with confirmed MS and CCSVI underwent endovascular treatment by the means of the uni- or bilateral jugular vein angioplasty with optional stent placement. All the patients completed 6 month follow-up. Their MS-related disability status and quality of life were evaluated 1, 3 and 6 months postoperatively by means of the following scales: Expanded Disability Status Scale (EDSS), Multiple Sclerosis Impact Scale (MSIS-29), Epworth Sleepiness Scale (ESS), Heat Intolerance scale (HIS) and Fatigue Severity Scale (FSS). For patency and restenosis rate assessment, the control US duplex Doppler examination was used. Six months after the procedure, restenosis in post-PTA jugular veins was found in 33% of cases. Among 17 patients who underwent stent implantation into the jugular vein, restenosis or partial in-stent thrombosis was identified in 55% of the cases. At the 6 month follow-up appointment, there was no significant improvement in the EDSS or the ESS. The endovascular treatment of the CCSVI improved the quality of life according to the MSIS-29 scale but only up to 3 months after the procedure (with no differences in the 6 month follow-up assessment). Six months after the jugular vein angioplasty (with or without stent placement), a statistically significant improvement was observed only in the FSS and the HIS. The endovascular treatment in patients with MS and concomitant CCSVI did not have an influence on the patient's neurological condition; however, in the mid-term follow-up, an improvement in some quality-of-life parameters was observed.
Cools, Bjorn; Brown, Stephen C; Heying, Ruth; Jansen, Katrijn; Boshoff, Derize E; Budts, Werner; Gewillig, Marc
2015-01-01
Pulmonary regurgitation (PR) following surgery of the right ventricular outflow tract (RVOT) is not innocent and leads to significant right heart dysfunction over time. Recent studies have demonstrated that percutaneous valves can be implanted in conduit free outflow tracts with good outcomes. To evaluate in patients with severe PR--anticipated to require future pulmonary valve replacement--the feasibility and safety of pre-stenting dilated non-stenotic patched conduit-free right ventricular outflow tracts before excessive dilation occurs, followed by percutaneous pulmonary valve implantation (PPVI). Twenty seven patients were evaluated, but only 23 were deemed suitable based on the presence of an adequate retention zone ≤ 24 mm defined by semi-compliant balloon interrogation of the RVOT. A 2 step procedure was performed: first the landing zone was prepared by deploying a bare stent, followed 2 months later by valve implantation. RVOT pre-stenting with an open cell bare metal stent (Andrastent XXL range) was performed at a median age of 13.0 years (range: 6.0-44.9) with a median weight of 44.3 kg (range: 20.0-88.0). Ninety six percent (22/23) of patients proceeded to PPVI a median of 2.4 months (range: 1.4-3.4) after initial pre-stent placement. Twenty one Melody valves and one 26 mm Edwards SAPIEN™ valve were implanted. Complications consisted of embolization of prestent (n = 1), scrunching (n = 4) and mild stent dislocation (n = 2). During follow-up, no stent fractures were observed and right ventricular dimensions decreased significantly. Post-surgical conduit-free non-stenotic RVOT with free pulmonary regurgitation can be treated percutaneously with a valved stent if anatomical (predominantly size) criteria are met. In experienced hands, the technique is feasible with low morbidity. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Zhou, Tanyang; Zhu, Tongyin; Zhang, Yuelin; Nie, Chunhui; Ai, Jing; Zhou, Guanhui; Zhang, Aibin; Dong, Meng-Jie; Wang, Wei-Lin
2016-01-01
Aim was to assess the therapeutic value of portal vein stenting (PVS) combined with iodine-125 seed (125I seed) strand endovascular implantation followed by transcatheter arterial chemoembolization (TACE) for treating patients with hepatocellular carcinoma (HCC) and portal vein tumor thrombus (PVTT). This was a retrospective study of 34 patients aged 29–81 years, diagnosed HCC with PVTT, and treated with PVS combined with 125I seed strand endovascular implantation followed by TACE between January 2012 and August 2014. Survival, stent patency, technical success rate, complications related to the procedure, and adverse events were recorded. The technical success rate was 100%. No serious procedure-related adverse event was recorded. The median survival was 147 days. The cumulative survival rates and stent patency rates at 90, 180, and 360 days were 94.1%, 61.8%, and 32.4% and 97.1% (33/34), 76.9% (24/34), and 29.4% (10/34), respectively. PVS combined with 125I seed strand endovascular implantation followed by TACE is feasible for patients with HCC and PVTT. It resulted in appropriate survival and stent patency, with no procedure-related adverse effects. PMID:27999793
Law, Ryan; Baron, Todd H
2013-09-01
Controversy exists on optimal endoscopic management for palliation of malignant hilar obstruction, with advocates for metal "side-by-side" (SBS) and "stent-in-stent" (SIS) techniques. We sought to evaluate the technical feasibility, efficacy, and outcomes of bilateral biliary self-expanding metal stents (SEMS) for treatment of malignant hilar obstruction using a stent with a 6Fr delivery system. This was a single-center, retrospective review of all patients who underwent bilateral placement of Zilver® biliary SEMS for malignant hilar obstruction from January 2010 to August 2012. Patients underwent endoscopic retrograde cholangiopancreatography with placement of stents using either the SIS or SBS stent techniques. Twenty-four patients (19 men, mean age 63 years) underwent bilateral stenting for malignant hilar obstruction during the study period. Seventeen and seven patients underwent the SBS and SIS technique, respectively. Cholangiocarcinoma (n=14) was the most common cause of hilar obstruction. Initial technical success was achieved in 24/24 (100%) of patients; however, 12 (50%) patients required re-intervention during the study period (median 98 days). Comparison of the SBS and SIS groups revealed no statistical difference with respect to need for re-intervention (P=0.31), successful re-intervention (P=0.60), or procedural length (P=0.89). Use of bilateral Zilver® SEMS in either the SBS or SIS configuration is safe, technically feasible, and effective for drainage of malignant hilar obstruction; however, duration of stent patency and procedure-free survival remain variable.
Late Pseudocoarctation Syndrome After Stent-Graft Implantation For Traumatic Aortic Rupture
DOE Office of Scientific and Technical Information (OSTI.GOV)
Letocart, Vincent, E-mail: vincent.letocart@chu-nantes.fr; Fau, Georges, E-mail: georges.fau@chu-nantes.fr; Tirouvanziam, Ashok, E-mail: ashok.tirouvanziam@chu-nantes.fr
The present observation illustrates an unusual complication occurring after stent-grafting (S-graft) for aortic isthmus rupture. A 22-year-old patient, treated by S-graft in the emergency department for traumatic aortic rupture, was readmitted 10 months later with pseudocoarctation syndrome. A membrane was found inside the stent-graft that had induced a pseudo-dissection, which caused the pseudocoarctation syndrome. Surgical treatment consisted of removing the stent-graft and membrane and replacing it with a vascular implant. The patient's clinical course was fair. The suggested mechanism was circumferential neoendothelialization of the stent-graft. Dehiscence caused the superior part of the membrane to drop into the lumen of themore » stent-graft creating a 'false channel' that compressed the 'true lumen' and induced 'pseudocoarctation' syndrome. The cause of the extensive neointimalization remains unexplained. Thoracic aortic stent-grafts require regular follow-up monitoring by angioscan or angio-magnetic resonance imaging.« less
Endotracheal nitinol stents: lessons from the learning curve.
Siegel, Bianca; Bent, John P; Ward, Robert F
2013-04-01
To reflect on lessons learned placing endotracheal nitinol stents in children. Case series with chart review. Tertiary care children's hospital. All children who underwent nitinol cervical tracheal stenting were included. Records were carefully reviewed for intraoperative and postoperative complications, management choices, outcomes, and factors that influenced results. Between 1999 and 2011, 7 children underwent 13 stent placements. Median follow-up was 5 years (range, 1-12 years). Six patients underwent stenting as a salvage procedure following open attempts at airway reconstruction. Four patients remain decannulated with their stent in place (median follow-up 7 years). The fifth patient had his stent removed endoscopically after 50 days because it became apparent that his obstruction was primarily laryngeal. The sixth child had his stent removed via a tracheal fissure after 14 months because of recalcitrant subglottic inflammation at the superior stent border. The seventh patient was decannulated for over 2 years but ultimately required tracheotomy replacement because of stenosis with the stent lumen. Complications included stent migration (23%), restenosis (29%), edema (29%), and granulation (57%). Endotracheal nitinol stents provide a realistic opportunity for decannulation in children for whom other options have failed but should be reserved only as a salvage procedure in severely complicated airways. Our experience has taught valuable lessons about stent indications, sizing, characteristics, and deployment, as well as means to avoid and manage their complications.
NASA Astrophysics Data System (ADS)
Boland, Enda L.; Grogan, James A.; Conway, Claire; McHugh, Peter E.
2016-04-01
Coronary stents have revolutionised the treatment of coronary artery disease. While coronary artery stenting is now relatively mature, significant scientific and technological challenges still remain. One of the most fertile technological growth areas is biodegradable stents; here, there is the possibility to generate stents that will break down in the body once the initial necessary scaffolding period is past (6-12 months) (Grogan et al. in Acta Biomater 7:3523, 2011) and when the artery has remodelled (including the formation of neo-intima). A stent angioplasty computational test-bed has been developed by the authors, based on the Abaqus software (DS-SIMULIA, USA), capable of simulating stent tracking, balloon expansion, recoil and in vivo loading in a atherosclerotic artery model. Additionally, a surface corrosion model to simulate uniform and pitting corrosion of biodegradable stents and a representation of the active response of the arterial tissue following stent implantation, i.e. neointimal remodelling, has been developed. The arterial neointimal remodelling simulations with biodegradable stent corrosion demonstrate that the development of new arterial tissue around the stent struts has a substantial effect on the mechanical behaviour of degrading stents.
Wang, Jian-Long; Qin, Zheng; Wang, Zhi-Jian; Shi, Dong-Mei; Liu, Yu-Yang; Zhao, Ying-Xin; Yang, Li-Xia; Cheng, Wan-Jun; Zhou, Yu-Jie
2018-02-01
Percutaneous coronary intervention (PCI) had become the major therapeutic procedure for coronary artery disease (CAD), but the high rate of in-stent restenosis (ISR) still remained an unsolved clinical problem in clinical practice. Increasing evidences suggested that diabetes mellitus (DM) was a major risk factor for ISR, but the risk predictors of ISR in CAD patients with DM had not been well characterized. The aim of this study was to investigate the clinical and angiographic characteristic predictors significantly associated with the occurrence of ISR in diabetic patients following coronary stenting with drug-eluting stent (DES). A total of 920 patients with diabetes who diagnosed CAD and underwent coronary DES implantation at Beijing Anzhen Hospital in China were consecutively enrolled from January 2012 to December 2012. Of these, 440 patients underwent the second angiography within ≥ 6 months due to the progression of treated target lesions. Finally, 368 of these patients who met the inclusion and exclusion criteria were followed up by angiography after baseline PCI. According to whether ISR was detected at follow-up angiography, patients were divided into the ISR group ( n = 74) and the non-ISR group ( n = 294). The independent predictors of ISR in patients with DM were explored by multivariate Cox's proportional hazards regression models. A total of 368 patients (260 women and 108 men) with a mean ages of 58.71 ± 10.25 years were finally enrolled in this study. Of these, ISR occurred in 74/368 diabetic patients (20.11%) by follow-up angiography. Univariate analysis showed that most baseline characteristics of the ISR and non-ISR group were similar. Patients in the ISR group had significantly higher serum very low density lipoprotein cholesterol (VLDL-C), triglyceride (TG) and uric acid (UA) levels, more numbers of target vessel lesions, higher prevalence of multi-vessel disease, higher SYNTAX score, higher rate of previous but lower rate of drinking compared with patients in the non-ISR group. The independent predictors of ISR in patients with DM after DES implantation included VLDL-C (HR = 1.85, 95% CI: 1.24-2.77, P = 0.002), UA (per 50 µmol/L increments, HR = 1.19, 95% CI: 1.05-1.34, P = 0.006), SYNTAX score (per 5 increments, HR = 1.34, 95% CI: 1.03-1.74, P = 0.031) and the history of PCI (HR = 3.43, 95% CI: 1.57-7.80, P = 0.003) by the multivariate Cox's proportional hazards regression analysis. The increased serum VLDL-C and UA level, higher SYNTAX score and the history of previous PCI were independent predictors of ISR in patients with DM after coronary DES implantation. It provided new evidence for physicians to take measures to lower the risk of ISR for the better management of diabetic patients after PCI.
Managing Drawbacks in Unconventional Successful Glaucoma Surgery: A Case Report of Stent Exposure
Fea, Antonio; Cannizzo, Paola Maria Loredana; Consolandi, Giulia; Lavia, Carlo Alessandro; Pignata, Giulia; Grignolo, Federico M.
2015-01-01
Traditional options in managing failed trabeculectomy (bleb needling, revision, additional incisional surgery and tube surgery) have a relatively high failure and complication rate. The use of microinvasive glaucoma surgery (MIGS) has generally been reserved to mild to moderate glaucoma cases, proving good safety profiles but significant limitations in terms of efficacy. We describe a patient who underwent MIGS (XEN Aquesys subconjunctival shunt implantation) after a prior failed trabeculectomy. After the surgery, the IOP was well controlled but as the stent was close to an area of scarred conjunctiva of the previous trabeculectomy, it became partially exposed. As a complete success was achieved, we decided to remove the conjunctiva over the exposed area and replace it by an amniotic membrane transplantation and a conjunctiva autograft. Six months after surgery, the unmedicated IOP is still well controlled with complete visual acuity recovery. PMID:26294994
Tokuda, Takahiro; Yamawaki, Masahiro; Takahara, Mitsuyohi; Mori, Shinsuke; Makino, Kenji; Honda, Yosuke; Takafuji, Hiroya; Takama, Takuro; Tsutsumi, Masakazu; Sakamoto, Yasunari; Takimura, Hideyuki; Kobayashi, Norihiro; Araki, Motoharu; Hirano, Keisuke; Ito, Yoshiaki
2016-03-18
Peri-stent contrast staining (PSS) after metallic drug-eluting stent deployment is associated with target lesion revascularization and very late stent thrombosis. However, the type of PSS that influences the clinical outcomes is unknown. Therefore, we aimed to reveal which PSS type was influencing clinical outcomes. This study included 5580 de novo lesions of 4405 patients who were implanted with a first- or second-generation drug-eluting stent and who were evaluated using follow-up angiography within 12 months after stent implantation. We compared the clinical outcomes of patients divided into focal PSS and segmental PSS groups for 6 years after stent implantation. Total PSS was observed in 97 lesions (2.2%), of which 42 and 55 lesions were focal and segmental PSS, respectively. Baseline characteristics were similar between groups, except for intraoperative chronic total occlusion (segmental PSS=47.3% versus focal PSS=11.9%, P=0.0001). The incidence of segmental PSS tended to be higher in patients with a first-generation drug-eluting stent (83.6% versus 16.4%, P=0.05). The cumulative incidence of stent thrombosis in the 6 years of segmental PSS group was significantly higher than that of the focal PSS group (13.9% versus 0%, P=0.04). The cumulative incidence of overall target lesion revascularization for restenosis, excluding target lesion revascularization procedures for stent thrombosis, was significantly higher in the segmental PSS group (38.0% versus 0%, P=0.01). The incidence of segmental PSS tended to be higher in patients with a first-generation drug-eluting stent and appeared to be significantly associated with target lesion revascularization and stent thrombosis. © 2016 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.
Camenzind, Edoardo; Boersma, Eric; Wijns, William; Mauri, Laura; Rademaker-Havinga, Tessa; Ordoubadi, Farzin Fath; Suttorp, Maarten J; Al Kurdi, Mohammad; Steg, Ph Gabriel
2014-08-01
To investigate the putative modifying effect of dual antiplatelet therapy (DAPT) use on the incidence of stent thrombosis at 3 years in patients randomized to Endeavor zotarolimus-eluting stent (E-ZES) or Cypher sirolimus-eluting stent (C-SES). Of 8709 patients in PROTECT, 4357 were randomized to E-ZES and 4352 to C-SES. Aspirin was to be given indefinitely, and clopidogrel/ticlopidine for ≥ 3 months or up to 12 months after implantation. Main outcome measures were definite or probable stent thrombosis at 3 years. Multivariable Cox regression analysis was applied, with stent type, DAPT, and their interaction as the main outcome determinants. Dual antiplatelet therapy adherence remained the same in the E-ZES and C-SES groups (79.6% at 1 year, 32.8% at 2 years, and 21.6% at 3 years). We observed a statistically significant (P = 0.0052) heterogeneity in treatment effect of stent type in relation to DAPT. In the absence of DAPT, stent thrombosis was lower with E-ZES vs. C-SES (adjusted hazard ratio 0.38, 95% confidence interval 0.19, 0.75; P = 0.0056). In the presence of DAPT, no difference was found (1.18; 0.79, 1.77; P = 0.43). A strong interaction was observed between drug-eluting stent type and DAPT use, most likely prompted by the vascular healing response induced by the implanted DES system. These results suggest that the incidence of stent thrombosis in DES trials should not be evaluated independently of DAPT use, and the optimal duration of DAPT will likely depend upon stent type (Clinicaltrials.gov number NCT00476957). Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.
Huang, H; Zhou, Y; Shao, J; Cai, J; Mei, Y; Wang, Y
2012-12-01
The aim of this paper was to develop a new self-expandable aortic valved stent following the shape of the sinus of Valsalva, which can be deployed above native leaflets for aortic regurgitation, and study it's effect on coronary artery flow when orthotopic implantation in and above native leaflets. New self-expandable aortic valved stent consist of nitinol stent and bovine pericardium, and was designed following the shape of the sinus of Valsalva, the bovine pericardium was tailed as native leaflet. Thirty-six swine hearts were divided into three equal groups of twelve. In Group A (N.=12), the new self-expandable aortic valved stents deployed in native leaflets. In Group B (N.=12), the new self-expandable aortic valved stents deployed above native leaflets. In Group C (N.=12), the cylinder-like valved stents deployed only in native leaflets. The measurements of each coronary flow rate and endoscopic inspections were repeated post-implantation. In Group A and C, valve implantation in native leaflets resulted in a significant decrease in both left and right coronary flows. In Group B, no significant change in either right or left coronary flow was found after new self-expandable aortic valved stent placement. Endoscopic inspections showed that in group A and C the native leaflets sandwiched between valved stent and aortic wall, whereas, in group B the native leaflets were under the artificial leaflets. Two kinds of stents deployed in native leaflets affect left and right coronary flows significantly. No significant effect was found when the new self-expandable aortic valved stent deployed above native leaflets. This new self-expandable aortic valved stent can be deployed above the native leaflets, which avoids the obstruction of native leaflets on coronary flow.
Ji, Woong Bae; Kwak, Jung Myun; Kang, Dong Woo; Kwak, Han Deok; Um, Jun Won; Lee, Sun-Il; Min, Byung-Wook; Sung, Nak Song; Kim, Jin; Kim, Seon Hahn
2017-01-01
The efficacy of stenting for right-sided malignant colonic obstruction is unknown. This study aimed to evaluate the safety, feasibility, and clinical benefits of self-expandable metallic stent insertion for right-sided malignant colonic obstruction. Clinical data from patients who underwent right hemicolectomy for right colon cancer from January 2006 to July 2014 at three Korea University hospitals were retrospectively reviewed. A total of 39 patients who developed malignant obstruction in the right-sided colon were identified, and their data were analyzed. Stent insertion was attempted in 16 patients, and initial technical success was achieved in 14 patients (87.5 %). No stent-related immediate complications were reported. Complete relief from obstruction was achieved in all 14 patients. Twenty-five patients, including two patients who failed stenting, underwent emergency surgery. In the stent group, 93 % (13/14) of patients underwent elective laparoscopic surgery, and only one surgery was converted to an open procedure. All patients in the emergency group underwent emergency surgery within 24 h of admission. In the emergency group, only 12 % (3/25) of patients underwent laparoscopic surgery, with one surgery converted to an open procedure. All patients in both groups underwent either laparoscopy-assisted or open right/extended right hemicolectomy with primary anastomoses as the first operation. The operative times, retrieved lymph nodes, and pathologic stage did not differ between the two groups. Postoperative hospital stay (9.4 ± 3.4 days in the stent group vs. 12.4 ± 5.9 in the emergency group, p = 0.089) and time to resume oral food intake (3.2 ± 2.1 days in the stent group vs. 5.7 ± 3.4 in the emergency group, p = 0.019) were shorter in the stent group. And there were no significant differences in disease-free survival and overall survival between the two groups. Stent insertion appears to be safe and feasible in patients with right-sided colonic malignant obstruction. It facilitates minimally invasive surgery and may result in better short-term surgical outcomes.
Zeng, Yaping; Cavalcante, Rafael; Tenekecioglu, Erhan; Suwannasom, Pannipa; Sotomi, Yohei; Collet, Carlos; Abdelghani, Mahammad; Jonker, Hans; Digne, Franck; Horstkotte, Dieter; Zehender, Manfred; Indolfi, Ciro; Saia, Francesco; Fiorilli, Rosario; Chevalier, Bernard; Bolognese, Leonardo; Goicolea, Javier; Nie, Shaoping; Onuma, Yoshinobu; Serruys, Patrick W
2017-04-01
The purpose of the study to assess the comparability of immediate changes in plaque/media volume (PV) on three modalities of intravascular ultrasound (IVUS) after implantation of either bioresorbable vascular scaffold (BVS) or everolimus-eluting metallic stent (EES) in Absorb II Study. The two devices have different device volume and ultrasound backscattering that may interfere with the "plaque/media" assessed by three modalities on IVUS: grayscale, backscattering of radiofrequency and brightness function. In a multicenter randomized controlled trial, 501 patients with stable or unstable angina underwent documentary IVUS pre- and post- implantation. The change in plaque/media volume (PV) was categorized into three groups according to the relative PV change in device segment: PV "increased" >+5% (PVI), PV unchanged ±5% (PVU), and PV decreased <-5% (PVD). The change in PV was re-evaluated three times: after subtraction of theoretical device volume, after analysis of echogenicity based on brightness function. In 449 patients, 483 lesions were analyzed pre- and post-implantation. "PVI" was more frequently observed in BVS (53.8%) than EES group (39.4%), p = 0.006. After subtraction of the theoretical device volume, the frequency of "PVI" decreased in both BVS (36.2%) and EES (32.1%) groups and became comparable (p = 0.581). In addition, the percentage of "PVI" was further reduced in both device groups after correction for either radiofrequency backscattering (BVS 34.4% vs. EES 22.6%) or echogenicity (BVS 25.2% vs. EES 9.7%). PV change in device segment was differently affected by BVS and EES devices implantation due to their differences in device volume and ultrasound backscattering. It implies that the lumen volume was also artifactually affected by the type of device implanted. Comparative IVUS assessment of lumen and plaque/media volume changes following implantation of BVS and EES requires specific methodological adjustment.
Kobayashi, Nobuaki; Mintz, Gary S; Witzenbichler, Bernhard; Metzger, D Christopher; Rinaldi, Michael J; Duffy, Peter L; Weisz, Giora; Stuckey, Thomas D; Brodie, Bruce R; Parvataneni, Rupa; Kirtane, Ajay J; Stone, Gregg W; Maehara, Akiko
2016-07-01
Intravascular ultrasound detects stent edge dissections after percutaneous coronary intervention that are not seen angiographically. This study investigated the association between stent edge dissections and clinical outcomes. ADAPT-DES (Assessment of Dual Antiplatelet Therapy With Drug-Eluting Stents) was a large-scale, prospective, multicenter study of patients undergoing drug-eluting stent implantation. In this prospective substudy, 2062 patients (2433 lesions) were evaluated with intravascular ultrasound to characterize the morphological features and clinical outcomes of stent edge dissection after percutaneous coronary intervention. The prevalence of post-percutaneous coronary intervention stent edge dissection was 6.6% per lesion (161 of 2433). Calcified plaque at the proximal stent edge (relative risk [RR]=1.72; P=0.04) and proximal stent edge expansion (RR=1.18; P=0.004) were predictors for proximal dissection; attenuated plaque at the distal stent edge (RR=3.52; P=0.004), distal reference plaque burden (RR=1.56; P<0.0001), and distal edge stent expansion (RR=1.11; P=0.02) were predictors for distal dissection. At 1-year follow-up, target lesion revascularization was more common in lesions with versus without dissection (5.2% versus 2.7%; P=0.04). Multivariable analysis indicated that residual dissection was associated with target lesion revascularization at 1-year follow-up (RR=2.67; P=0.02). Among lesions with dissection, smaller effective lumen area increased the risk of target lesion revascularization at 1-year follow-up (cutoff value of 5.1 mm(2); P=0.05). Greater stent expansion and the presence of large, calcified, and/or attenuated plaques were independent predictors of stent edge dissection. Residual stent edge dissection, especially with a smaller effective lumen area, was associated with target lesion revascularization during 1-year follow-up after drug-eluting stent implantation. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00638794. © 2016 American Heart Association, Inc.
Drug eluting stents and modern stent technologies for in-stent restenosis.
Werner, Martin
2017-08-01
The implantation of metallic stents has become a standard procedure to improve the outcome after angioplasty of peripheral vessels. However, the occurrence of in-stent restenosis is hampering the long-term efficacy of these procedures and is associated with re-occurrence of symptoms. The optimal treatment modality for in-stent-restenosis in the peripheral vasculature is not well examined. This review discusses the existing evidence for the treatment of in-stent restenosis with drug eluting stents and modern stent technologies.
Kowalski, Wolfgang; Dammer, Markus; Bakczewitz, Frank; Schmitz, Klaus-Peter; Grabow, Niels; Kessler, Olaf
2015-09-01
Drug eluting stents (DES) consist of platform, coating and drug. The platform often is a balloon-expandable bare metal stent made of the CoCr alloy L-605 or stainless steel 316 L. The function of the coating, typically a permanent polymer, is to hold and release the drug, which should improve therapeutic outcome. Before implantation, DES are compressed (crimped) to allow implantation in the human body. During implantation, DES are expanded by balloon inflation. Crimping, as well as expansion, causes high stresses and high strains locally in the DES struts, as well as in the polymer coating. These stresses and strains are important design criteria of DES. Usually, they are calculated numerically by finite element analysis (FEA), but experimental results for validation are hardly available. In this work, the X-ray diffraction (XRD) sin(2)ψ-technique is applied to in-situ determination of stress conditions of bare metal L-605 stents, and Poly-(L-lactide) (PLLA) coated stents. This provides a realistic characterization of the near-surface stress state and a validation option of the numerical FEA. XRD-results from terminal stent struts of the bare metal stent show an increasing compressive load stress in tangential direction with increasing stent expansion. These findings correlate with numerical FEA results. The PLLA-coating also bears increasing compressive load stress during expansion. Copyright © 2015 Elsevier Ltd. All rights reserved.
Kim, J H; Shin, J H; Shin, D H; Moon, M-W; Park, K; Kim, T-H; Shin, K M; Won, Y H; Han, D K; Lee, K-R
2011-01-01
Objective Neointimal hyperplasia is a major complication of endovascular stent placement with consequent in-stent restenosis or occlusion. Improvements in the biocompatibility of stent designs could reduce stent-associated thrombosis and in-stent restenosis. We hypothesised that the use of a diamond-like carbon (DLC)-coated nitinol stent or a polyethylene glycol (PEG)-DLC-coated nitinol stent could reduce the formation of neointimal hyperplasia, thereby improving stent patency with improved biocompatibility. Methods A total of 24 stents were implanted, under general anaesthesia, into the iliac arteries of six dogs (four stents in each dog) using the carotid artery approach. The experimental study dogs were divided into three groups: the uncoated nitinol stent group (n = 8), the DLC-nitinol stent group (n = 8) and the PEG-DLC-nitinol stent group (n = 8). Results The mean percentage of neointimal hyperplasia was significantly less in the DLC-nitinol stent group (26.7±7.6%) than in the nitinol stent group (40.0±20.3%) (p = 0.021). However, the mean percentage of neointimal hyperplasia was significantly greater in the PEG-DLC-nitinol stent group (58.7±24.7%) than in the nitinol stent group (40.0±20.3%) (p = 0.01). Conclusion Our findings indicate that DLC-coated nitinol stents might induce less neointimal hyperplasia than conventional nitinol stents following implantation in a canine iliac artery model; however, the DLC-coated nitinol stent surface when reformed with PEG induces more neointimal hyperplasia than either a conventional or DLC-coated nitinol stent. PMID:21325363
Assessment of a Polyester-Covered Nitinol Stent in the Canine Aorta and Iliac Arteries
DOE Office of Scientific and Technical Information (OSTI.GOV)
Castaneda, Flavio; Ball-Kell, Susan M.; Young, Kate
Purpose: To evaluate the patency and healing characteristics of a woven polyester fabric-covered stent in the canine model.Methods: Twenty-four self-expanding covered stents were placed in the infrarenal aorta and bilateral common iliac arteries of eight dogs and evaluated at 1 (n = 2), 3 (n = 2), and 6 (n = 4) months. Stent assessment was done using angiography prior to euthanasia, and light and scanning electron microscopy.Results: Angiographically, just prior to euthanasia, 8 of 8 aortic and 14 of 16 iliac endovascular covered stents were patent. Histologically, the stented regions showed complete endothelialization 6 months after graft implantation. Amore » neointima had formed inside the stented vessel regions resulting in complete encasement of the fabric-covered stent by 3 months after graft implantation. Medial compression with smooth muscle cell atrophy was present in all stented regions. Explanted stent wires, examined by scanning electron microscopy, showed pitting but no cracks or breakage.Conclusion: The covered stent demonstrated predictable healing and is effective in preventing stenosis in vessels 10.0 mm or greater in diameter but does not completely preclude stenosis in vessels 6.0 mm or less in diameter.« less
Bio-Adaption between Magnesium Alloy Stent and the Blood Vessel: A Review.
Ma, Jun; Zhao, Nan; Betts, Lexxus; Zhu, Donghui
2016-09-01
Biodegradable magnesium (Mg) alloy stents are the most promising next generation of bio-absorbable stents. In this article, we summarized the progresses on the in vitro studies, animal testing and clinical trials of biodegradable Mg alloy stents in the past decades. These exciting findings led us to propose the importance of the concept "bio-adaption" between the Mg alloy stent and the local tissue microenvironment after implantation. The healing responses of stented blood vessel can be generally described in three overlapping phases: inflammation, granulation and remodeling. The ideal bio-adaption of the Mg alloy stent, once implanted into the blood vessel, needs to be a reasonable function of the time and the space/dimension. First, a very slow degeneration of mechanical support is expected in the initial four months in order to provide sufficient mechanical support to the injured vessels. Although it is still arguable whether full mechanical support in stented lesions is mandatory during the first four months after implantation, it would certainly be a safety design parameter and a benchmark for regulatory evaluations based on the fact that there is insufficient human in vivo data available, especially the vessel wall mechanical properties during the healing/remodeling phase. Second, once the Mg alloy stent being degraded, the void space will be filled by the regenerated blood vessel tissues. The degradation of the Mg alloy stent should be 100% completed with no residues, and the degradation products (e.g., ions and hydrogen) will be helpful for the tissue reconstruction of the blood vessel. Toward this target, some future research perspectives are also discussed.
Bio-Adaption between Magnesium Alloy Stent and the Blood Vessel: A Review
Ma, Jun; Zhao, Nan; Betts, Lexxus; Zhu, Donghui
2016-01-01
Biodegradable magnesium (Mg) alloy stents are the most promising next generation of bio-absorbable stents. In this article, we summarized the progresses on the in vitro studies, animal testing and clinical trials of biodegradable Mg alloy stents in the past decades. These exciting findings led us to propose the importance of the concept “bio-adaption” between the Mg alloy stent and the local tissue microenvironment after implantation. The healing responses of stented blood vessel can be generally described in three overlapping phases: inflammation, granulation and remodeling. The ideal bio-adaption of the Mg alloy stent, once implanted into the blood vessel, needs to be a reasonable function of the time and the space/dimension. First, a very slow degeneration of mechanical support is expected in the initial four months in order to provide sufficient mechanical support to the injured vessels. Although it is still arguable whether full mechanical support in stented lesions is mandatory during the first four months after implantation, it would certainly be a safety design parameter and a benchmark for regulatory evaluations based on the fact that there is insufficient human in vivo data available, especially the vessel wall mechanical properties during the healing/remodeling phase. Second, once the Mg alloy stent being degraded, the void space will be filled by the regenerated blood vessel tissues. The degradation of the Mg alloy stent should be 100% completed with no residues, and the degradation products (e.g., ions and hydrogen) will be helpful for the tissue reconstruction of the blood vessel. Toward this target, some future research perspectives are also discussed. PMID:27698548
Fujimoto, Wataru; Sawada, Takahiro; Toba, Takayoshi; Takahashi, Yu; Miyata, Taishi; Oishi, Shogo; Osue, Tsuyoshi; Onishi, Tetsuari; Takaya, Tomofumi; Shimane, Akira; Taniguchi, Yasuyo; Kawai, Hiroya; Yasaka, Yoshinori
2018-07-01
The use of short-duration dual antiplatelet therapy (DAPT) remains controversial. To investigate efficacy and safety of short-duration DAPT, we performed a detailed comparison of intra-stent conditions by optical coherence tomography (OCT) after second-generation drug-eluting stent implantation with short-term and standard DAPT. Eighty-two consecutive patients with stable angina pectoris who received Resolute zotarolimus-eluting stents (R-ZESs; Medtronic Cardiovascular, Santa Rosa, CA, USA) were enrolled. Patients were assigned to 3-month (3M group: 41 patients) and standard (standard group: 41 patients) DAPT. In the 3M group, clopidogrel was discontinued 3 months after stent implantation. In the standard group, DAPT was maintained until follow-up OCT. At 9 months, neointimal proliferation was significantly larger in the 3M group, but there were no significant between-group differences in the proportion of uncovered and malapposed strut. The prevalence of abnormal intra-stent tissue (AIT) at 9 months was equivalent between groups. A multiple regression analysis revealed malapposition at 9 months as the strongest independent predictor of AIT at 9 months, and the prevalence of AIT was not associated with DAPT duration. Over 2 years, cardiac events were equal between groups; however, major bleeding was higher tendency in the standard group than in the 3M group. This OCT study indicated that reducing DAPT's duration may provide acceptable arterial healing in patients with implanted R-ZESs. Copyright © 2018 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.
Stefanadis, Christodoulos; Toutouzas, Konstantinos; Stefanadi, Elli; Lazaris, Andreas; Patsouris, Efstratios; Kipshidze, Nicholas
2007-12-01
Neovascularization is associated with destabilization of atheromatic plaques. Increased expression of vascular endothelial growth factor (VEGF) is important in the process of neovascularization. We assessed the effect of bevacizumab, a monoclonal antibody specific for VEGF, on neovascularization. We used 12 New Zealand rabbits under atherogenic diet for 3 weeks. We immersed a phosphorycholine coated stent into a solution of 4 ml bevacizumab according to previous studies. Twelve eluting stents and 12 non-eluting stents were implanted in the middle segment of the rabbit's iliac arteries. Follow-up angiography was performed at 4 weeks and tissues were obtained for histological analysis. The procedure of stent loading with bevacizumab and stent implantation was successful. There was no difference in angiographic measurements before, after implantation and at follow-up between the two groups. mean neointimal thickness (0.09+/-0.02 versus 0.12+/-0.02 mm, p<0.01), and mean neointimal area (1.08+/-0.09 versus 1.20+/-0.12 mm(2), p<0.01) were less in the bevacizumab treated segments. bevacizumab-treated arterial segments demonstrated significantly decreased microvessel density compared with the control group (1.69+/-0.06 CI: 1.65-1.73 versus 15.68+/-0.56 CI: 15.32-16.04 vessels per mm(2), p<0.001) and vegf expression was decreased in the media and adventitia of bevacizumab group. Endothelialization, inflammation and injury scores were similar between the two groups. These results suggest that bevacizumab-eluting stent implantation in rabbit iliac arteries is safe, and inhibits neovascularization without affecting the endothelialization.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stefanczyk, Ludomir, E-mail: stefanczyk_l@wp.pl; Czeczotka, Jaroslaw; Elgalal, Marcin
2011-02-15
The treatment of posttraumatic aneurysms of peripheral arteries using covered stents is increasingly commonplace. We present the case of a 10-year-old girl with a pseudoaneurysm of the subclavian artery complicated by an arteriobronchial fistula with hemorrhaging into the bronchial tree and distal subclavian artery occlusion. Despite the lack of artery patency, endovascular stent graft implantation was successful. Pseudoaneurysm exclusion and involution was achieved, together with a patent implant and maintained collateral circulation patency.
Angiographic and Interventional Management for a Esophagopericardial Fistula
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wu, Keng, E-mail: zjwukeng@hotmail.com; You, Qiong, E-mail: qiong_you@yahoo.cn; He, Song-Jian
2013-06-19
We reported a case of a 78-year-old patient with esophagopericardial fistula who was referred for angiographic and interventional management. Emergent implantation of the esophageal stent could not lengthen or even save the patient’s life. One week later, the patient died of multiple organ failure, which was probably from formation of granulation tissue and stent migration. Therefore, if the inflammatory to the esophagopericardial fistula had been better controlled initially, and the implantation of the esophageal stent delayed, our patient would have survived.
Aortobronchial fistula caused by an endobronchial lobar Y stent: a word of caution.
Härting, Margarete; Welter, Stefan; Aigner, Clemens
2018-04-25
A 17-year-old female patient with a history of pulmonary tuberculosis was admitted with progressive dyspnoea and haemoptysis. Five months prior to admission, a left bronchial carina Y stent was implanted. Because of the already destroyed parenchyma, a pneumonectomy was planned. Intraoperatively, an aortobronchial fistula was discovered as the source of bleeding, which could be stopped by pledget-armed sutures. The formation of an aortobronchial fistula has to be considered as a potential source of endobronchial bleeding after stent implantation.
Stenting and surgery for coronary vasospasm : the wrong solution fails to solve the problem.
Nedeljkovic, Milan A; Ostojic, Miodrag; Lalic, Nebojsa; Beleslin, Branko; Nedeljkovic, Ivana; Lalic, Katarina; Ristic, Miljko; Giga, Vojislav; Angelkov, Lazar; Tomasevic, Miloje; Kanjuh, Vladimir
2009-11-01
A 55-year-old man, with a history of medically uncontrolled coronary vasospasm, presented for evaluation of chest pain 6 months after implantation of left internal mammary artery. Due to recurrent episodes of vasospastic angina and serious complications of coronary spasm (ventricular fibrillation, myocardial infarction), a stent had previously been implanted in the proximal part of left anterior descending artery at the site of angiographically and ergonovine-proven coronary spasm, with subsequent in-stent restenosis.
Carotid artery stenting in patients with symptomatic carotid stenosis: a single-center series.
Kessler, I; Gory, B; Macian, F; Nakiri, G; Al-Khawaldeh, M; Riva, R; Boncoeur, M P; Mounayer, C
2013-03-01
Carotid angioplasty with stenting (CAS) in patients with carotid stenosis (CS) has become more restricted in France especially since the disclosure of such studies as EVA-3S and Stent-supported percutaneous angioplasty of the carotid artery versus endarterectomy (SPACE). This report is of a series of CS cases contraindicated for endarterectomy that underwent CAS at a French center of interventional neuroradiology. Fifty-five patients with symptomatic CS more than 60% consecutively submitted to CAS between September 2008 and February 2011. The primary endpoint was either death or stroke within 30 days of the procedure; a secondary goal was to identify any possible factors that might have influenced the success and outcome of the intervention. The overall periprocedural stroke/death rate at 30 days was 5.4% (three out of 55 patients), with three non-disabling strokes and no deaths. Twenty-seven patients (49.1%) were treated with a cerebral protection device (CPD). Stent placement was achieved in all cases. Open- and closed-cell stents were implanted in 40 (72.7%) and 15 procedures (27.3%), respectively. Neither the use of a CPD, the carotid stent cell design nor any anatomical or technical factors were associated with a lower risk of stroke or death within 30 days of CAS. CAS in symptomatic patients with CS contraindicated for endarterectomy in this selected French series proved feasible and safe, with acceptable levels of morbidity. Use of a CPD, type of stent (open- or closed-cell), and anatomical and technical factors had no influence on the success of the procedure or the outcome within 30 days of the operation. Copyright © 2012 Elsevier Masson SAS. All rights reserved.
Distribution of nickel after modified nitinol stent implantation in animals
NASA Astrophysics Data System (ADS)
Chepeleva, E.; Sergeevichev, D.; Lotkov, A.; Kashin, O.; Korobeynikov, A.; Kozyr, K.; Baystrukov, V.; Zubarev, D.; Kretov, E.; Pokushalov, E.
2017-09-01
Intravascular stenting of arteries in atherosclerotic lesions is one of the most frequently performed procedures in cardiovascular surgery today. Most stents are made of various stainless-steel alloys and other metals (such as nitinol). Nitinol is a biocompatible, superplastic and corrosion resistant material with an important feature of shape memory. However, the composition of this alloy includes nickel, which shows toxicity to the kidneys, liver, lungs, heart and other organs when it accumulates in the organism. In this research we investigated the nickel content in serum, urine and hair of the laboratory animals after implantation of nitinol stents treated with plasma ionic surface modification by silicon.
Xiao, Dinghua; Liu, Shaojun; Yan, Hanguang; Wang, Xiaoyan
2018-05-28
To explore the function of esophageal small balloon or papillary sphincter knife in the treatment of stent implantation for colorectal malignant obstruction, and to improve the success rate of colonic stent placement in such patients. Methods: A total of 49 patients with colorectal cancer complicated with almost complete obstruction or colorectal cancer were enrolled for this study. The esophageal small balloon or papillary sphincter knife was used in the guide wires. The guide wires gradually crossed the tumor gap and they were placed in the contralateral intestinal cavity with balloon progression. X-ray was then used to confirm whether the guide wire was inserted in the lesion intestinal cavity, and then the metal bare stent was inserted. Results: The guide wires was successfully inserted with conventional methods in these 49 cases, while they were also successfully placed the guide wire and the stent in the new way. Conclusion: For the patients with colorectal cancer complicated with complete obstruction or colorectal cancer located in obviously angled location, the use of esophageal small balloon or papillary sphincter knife can help the guide wire insert. They greatly improve the success rate of stent implantation.
Intravascular ultrasound for intracranial angioplasty and stent placement: technical case report.
Wehman, J Christopher; Holmes, David R; Hanel, Ricardo A; Levy, Elad I; Hopkins, L Nelson
2006-10-01
Intravascular ultrasound (IVUS) imaging has been used extensively in coronary artery interventions and has provided invaluable information for the understanding and treatment of coronary arterial disease. We present here the first description, to our knowledge, of IVUS-guided intracranial arterial interventions in the clinical setting. Two patients underwent intracranial angioplasty and stent placement with the assistance of IVUS for the evaluation of their lesions. One patient underwent stenting to treat an occlusive dissection of the left internal carotid artery that occurred during arteriovenous malformation embolization. Another patient underwent angioplasty and stenting for high-grade restenosis of a basilar artery atherosclerotic lesion. Both patients underwent successful revascularization procedures. The patient with the dissection had a small intraventricular and parenchymal hemorrhage documented by computed tomography 4 hours after treatment, but did not develop hydrocephalus or further hemorrhage. Both patients did well clinically and had no permanent neurological deficits. IVUS provided important information in terms of lesion evaluation, stent selection, and stent placement in each case. IVUS of the intracranial circulation may assist the performance of intracranial angioplasty and stenting. It provides useful information that can affect clinical decisions. It may prove to be a valuable tool in clinical use and enhance our understanding of vascular disease of the intracranial circulation, as it has in the coronary circulation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sommer, C. M., E-mail: christof.sommer@med.uni-heidelberg.de; Grenacher, L.; Stampfl, U.
The purpose of this study was to evaluate the impact of stent design on in-stent stenosis in rabbit iliac arteries. Four different types of stent were implanted in rabbit iliac arteries, being different in stent design (crown or wave) and strut thickness (50 or 100 {mu}m). Ten stents of each type were implanted. Each animal received one crown and one wave stent with the same strut thickness. Follow-up was either 12 weeks (n = 10 rabbits) or 24 weeks (n = 10 rabbits). Primary study end points were angiographic and microscopic in-stent stenosis. Secondary study end points were vessel injury,more » vascular inflammation, and stent endothelialization. Average stent diameter, relative stent overdilation, average and minimal luminal diameter, and relative average and maximum luminal loss were not significantly different. However, a trend to higher relative stent overdilation was recognized in crown stents compared to wave stents. A trend toward higher average and minimal luminal diameter and lower relative average and maximum luminal loss was recognized in crown stents compared to wave stents with a strut thickness of 100 {mu}m. Neointimal height, relative luminal area stenosis, injury score, inflammation score, and endothelialization score were not significantly different. However, a trend toward higher neointimal height was recognized in crown stents compared to wave stents with a strut thickness of 50 {mu}m and a follow-up of 24 weeks. In conclusion, in this study, crown stents seem to trigger neointima. However, the optimized radial force might equalize the theoretically higher tendency for restenosis in crown stents. In this context, also more favorable positive remodeling in crown stents could be important.« less
Lee, Jong Joo; Kim, Dong Myung; Kim, Tae Woo
2009-01-01
Purpose To investigate the immediate and long-term outcomes of Ahmed glaucoma valve (AGV) implantation with silicone tube ligation and removable external stents. Methods This retrospective non-comparative study investigated the outcomes of AGV implantation with silicone tube ligation and removable external stents in 95 eyes (90 patients) with at least 12 months of postoperative follow-up. Qualified success was defined as an intraocular pressure (IOP) of ≤21 mmHg and ≥6 mmHg regardless of anti-glaucoma medication. Those who required additional glaucoma surgery, implant removal or who had phthisis bulbi were considered failures. Hypotony was defined as an IOP of <6 mmHg. Results Mean IOP reduced from 37.1±9.7 mmHg preoperatively to 15.2±5.6 mmHg at 12 months postoperatively (p<0.001). Qualified success was achieved in 84.2% at 1 year. Hypotony with an IOP of <6 mmHg was seen in 8.4% and an IOP of <5 mmHg in 3.2% on the first postoperative day. No case of hypotony required surgical intervention. Suprachoroidal hemorrhage did not occur in this study. When stents were removed on the first postoperative day because of an insufficient IOP decrease, the mean IOP decreased significantly from 42.0 mmHg to 14.1 mmHg (p<0.001) after 1 hour. The most common complication was hyphema, which occurred in 17.9%. Conclusions Hypotony-related early complications requiring surgical intervention were reduced by ligation and external stents in the tube. In addition, early postoperative high IOPs were managed by removing external stents. The described method can prevent postoperative hypotony after AGV implantation and showed long-term success rates comparable to those reported previously. PMID:19568356
Lee, Jong Joo; Park, Ki Ho; Kim, Dong Myung; Kim, Tae Woo
2009-06-01
To investigate the immediate and long-term outcomes of Ahmed glaucoma valve (AGV) implantation with silicone tube ligation and removable external stents. This retrospective non-comparative study investigated the outcomes of AGV implantation with silicone tube ligation and removable external stents in 95 eyes (90 patients) with at least 12 months of postoperative follow-up. Qualified success was defined as an intraocular pressure (IOP) of
Wolfschmidt, Franziska; Hassold, Nicole; Goltz, Jan Peter; Leyh, Rainer; Bley, Thorsten Alexander; Kickuth, Ralph
2015-09-01
To evaluate the feasibility, effectiveness, and safety of using a commercially available reentry catheter with fluoroscopic guidance to gain controlled target lumen reentry for fenestration in patients with aortic dissection. This retrospective study was approved by the local institutional review board; informed consent was waived. Between April 2009 and December 2013, 13 consecutive patients (10 men and three women; mean age, 51.2 years; range, 30.0-77.0 years; mean age of women, 47.0 years; range, 30.0-69.0 years; mean age of men, 52.4 years; range, 35.0-77.0 years) with aortic dissection and spinal (n = 4), renal (n = 7), mesenteric (n = 2), and/or iliofemoral (n = 9) malperfusion syndrome were included. All patients received target lumen reentry by means of balloon fenestration of the aortic dissection flap. A reentry catheter was used for fluoroscopically guided puncture of the target lumen. Technical success, clinical outcome, Stanford type of dissection, procedure time, number of fenestrations of the intimal flap per patient, necessity of additional aortic stent-graft implantation and/or placement of a bare metal stent, complications, and follow-up images were evaluated. Pre- and postinterventional systolic blood pressure gradients between the true lumen and the false lumen were compared (Wilcoxon signed-rank test). Safety of the reentry catheter maneuver was estimated with the Clopper-Pearson method. Use of the reentry catheter was technically successful in all 13 (100%) patients and clinically successful in 10 of 13 (77%) patients. Four patients had type A and nine had type B dissection. The mean clinical follow-up period was 14.2 months. Median procedure time was 71 minutes. In four patients, fenestration of the intimal flap was performed twice. Three patients underwent additional aortic stent grafting, four patients underwent placement of an iliofemoral stent, and one patient underwent placement of a carotid artery stent. Blood pressure gradients between the true lumen and the false lumen were significantly reduced (P = .0313). One patient who had a combination of syndromes died of multiorgan failure. The applied commercially available reentry catheter seems to be a reliable and safe tool that may be useful for gaining target lumen reentry with reasonably good clinical outcomes.
Neuhann, Tobias H
2015-12-01
To evaluate long-term safety and efficacy of iStent trabecular micro-bypass stent implantation during cataract surgery in patients with primary open-angle, pseudo-exfoliation glaucoma, ocular hypertension, or secondary or post-traumatic glaucoma. AaM Augenklinik am Marienplatz, Munich, Germany. Prospective, open-label, non-randomized study. Preoperative and postoperative evaluations included intra-ocular pressure (IOP), topical ocular hypotensive medication use, cup/disc ratio, corrected-distance visual acuity (CDVA), complications, and adverse events. A single trabecular micro-bypass stent was implanted through the same temporal, limbal incision used for cataract surgery via phacoemulsification in a consecutive series of 62 eyes of 43 patients. To date, a total of 41 eyes have been followed for 3 years postoperatively, whereas long-term postoperative follow-up on the remaining patients is ongoing. Mean preoperative IOP was 24.1 ± 6.9 mm Hg on a mean of 1.8 medications (±0.9). Analyses of eyes with no secondary surgical intervention showed mean IOP reduction to 14.8 ± 4.2 mm Hg at 12 months (n = 61), 14.5 ± 2.2 mm Hg at 24 months (n = 42), and 14.9 ± 2.3 mm Hg at 36 months (n = 39). Medications were eliminated in 74% of eyes at 36 months. Five eyes, 4 with previous glaucoma surgeries and 1 with pseudo-exfoliation syndrome, required additional glaucoma surgery after stent implantation. No intra-operative or postoperative complications typically seen with conventional glaucoma surgeries occurred after stent implantation. At 36 months, CDVA was 20/40 or better in 38 eyes (93%). Trabecular micro-bypass stent implantation during cataract surgery was safe and effective in patients with ocular hypertension or glaucoma as measured by a sustained reduction in IOP and medication use and an excellent safety profile through 3 years after surgery. Dr. Neuhann has no financial or proprietary interest in any material or method mentioned. Glaukos Corp. provided editorial assistance in the preparation of the manuscript. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Iijima, Raisuke; Kougame, Norihiro; Hara, Hidehiko; Moroi, Masao; Nakamura, Masato
2018-06-12
The aim of this study was to investigate whether drug-coated balloon (DCB) treatment is effective for de novo coronary lesions that are unsuitable for drug-eluting stent (DES) implantation.Methods and Results:This retrospective study included 118 de novo lesions that were not suitable for DES implantation. Of the lesions, 40% was treated because of very small vessel disease. Patients with planned non-cardiac surgery and at high bleeding risk were 3% and 19%, respectively, and lesions that easily develop stent fracture comprised 26%. Clinically driven target lesion revascularization (TLR) was the primary endpoint. The rate of suboptimal lesion preparation before DCB treatment was set as the secondary endpoint. Optimal lesion preparation was defined as acquisition of Thrombolysis in Myocardial Infarction flow grade 3, minor coronary dissection, and residual stenosis ≤30%. The rate of suboptimal lesion preparation was 2.5% and 3 patients needed bail-out stenting. Accordingly, 115 patients were treated with a DCB. Clinically driven TLR had occurred in 8 patients (7.0%) at the 8-month follow-up. The presence of chronic total occlusion was identified as an independent predictor for TLR (odds 11.57; 95% confidence interval, 1.38-135.54; P=0.02). For lesions that are unsuitable for stent implantation, stent-less intervention using a DCB should be considered initially. The present study also highlighted that lesion preparation is key to a successful DCB strategy.
O'Brien, Caroline C; Kolandaivelu, Kumaran; Brown, Jonathan; Lopes, Augusto C; Kunio, Mie; Kolachalama, Vijaya B; Edelman, Elazer R
2016-01-01
Stacking cross-sectional intravascular images permits three-dimensional rendering of endovascular implants, yet introduces between-frame uncertainties that limit characterization of device placement and the hemodynamic microenvironment. In a porcine coronary stent model, we demonstrate enhanced OCT reconstruction with preservation of between-frame features through fusion with angiography and a priori knowledge of stent design. Strut positions were extracted from sequential OCT frames. Reconstruction with standard interpolation generated discontinuous stent structures. By computationally constraining interpolation to known stent skeletons fitted to 3D 'clouds' of OCT-Angio-derived struts, implant anatomy was resolved, accurately rendering features from implant diameter and curvature (n = 1 vessels, r2 = 0.91, 0.90, respectively) to individual strut-wall configurations (average displacement error ~15 μm). This framework facilitated hemodynamic simulation (n = 1 vessel), showing the critical importance of accurate anatomic rendering in characterizing both quantitative and basic qualitative flow patterns. Discontinuities with standard approaches systematically introduced noise and bias, poorly capturing regional flow effects. In contrast, the enhanced method preserved multi-scale (local strut to regional stent) flow interactions, demonstrating the impact of regional contexts in defining the hemodynamic consequence of local deployment errors. Fusion of planar angiography and knowledge of device design permits enhanced OCT image analysis of in situ tissue-device interactions. Given emerging interests in simulation-derived hemodynamic assessment as surrogate measures of biological risk, such fused modalities offer a new window into patient-specific implant environments.
Waidmann, Oliver; Trojan, Jörg; Friedrich-Rust, Mireen; Sarrazin, Christoph; Bechstein, Wolf Otto; Ulrich, Frank; Zeuzem, Stefan; Albert, Jörg Gerhard
2013-01-01
AIM: To compare clinical success and complications of uncovered self-expanding metal stents (SEMS) vs covered SEMS (cSEMS) in obstruction of the small bowel. METHODS: Technical success, complications and outcome of endoscopic SEMS or cSEMS placement in tumor related obstruction of the duodenum or jejunum were retrospectively assessed. The primary end points were rates of stent migration and overgrowth. Secondary end points were the effect of concomitant biliary drainage on migration rate and overall survival. The data was analyzed according to the Strengthening the Reporting of Observational Studies in Epidemiology guidelines. RESULTS: Thirty-two SEMS were implanted in 20 patients. In all patients, endoscopic stent implantation was successful. Stent migration was observed in 9 of 16 cSEMS (56%) in comparison to 0/16 SEMS (0%) implantations (P = 0.002). Stent overgrowth did not significantly differ between the two stent types (SEMS: 3/16, 19%; cSEMS: 2/16, 13%). One cSEMS dislodged and had to be recovered from the jejunum by way of laparotomy. Time until migration between SEMS and cSEMS in patients with and without concomitant biliary stents did not significantly differ (HR = 1.530, 95%CI 0.731-6.306; P = 0.556). The mean follow-up was 57 ± 71 d (range: 1-275 d). CONCLUSION: SEMS and cSEMS placement is safe in small bowel tumor obstruction. However, cSEMS is accompanied with a high rate of migration in comparison to uncovered SEMS. PMID:24115817
Valgimigli, Marco; Patialiakas, Athanasios; Thury, Attila; Colangelo, Salvatore; Campo, Gianluca; Tebaldi, Matteo; Ungi, Imre; Tondi, Stefano; Roffi, Marco; Menozzi, Alberto; de Cesare, Nicoletta; Garbo, Roberto; Meliga, Emanuele; Testa, Luca; Gabriel, Henrique M; Airoldi, Flavio; Ferlini, Marco; Liistro, Francesco; Dellavalle, Antonio; Vranckx, Pascal; Briguori, Carlo
2013-11-01
The use of drug-eluting stent (DES) instead of bare-metal stent (BMS) in patients at high stent thrombosis or bleeding risk as well as in those at low restenosis risk (ie, uncertain DES candidates) remains a matter of debate. Zotarolimus-Eluting Endeavor Sprint stent (E-ZES) (Santa Rosa, CA) is a hydrophilic polymer-based second-generation device with unique drug fast-release profile, which may allow for a shorter dual antiplatelet therapy (DAPT) duration without safety concerns. The primary objective is to assess whether E-ZES implantation followed by a shorter than currently recommended course of DAPT will decrease the incidence of 12-month major adverse cardiovascular events as compared with BMS in undefined DES recipients. Actual duration of DAPT regimen will be dictated by patients' characteristics and not by stent type and, as such, can be as short as 30 days after intervention in both stent groups. The ZEUS study is an open-label randomized clinical trial conducted at 20 clinical sites in Italy, Switzerland, Portugal, and Hungary. With 1,600 individuals, this study will have 85% power to detect a 33% difference in the primary end point consisting of the composite of death, nonfatal myocardial infarction, or target vessel revascularization. The ZEUS trial aims to assess whether the use of E-ZES, followed by a DAPT duration regimen based on patients' characteristics and not by stent type, is superior to conventional BMS implantation in undefined DES recipients who qualify for the presence of high thrombosis, bleeding, or low restenosis risk criteria. © 2013.
McElhinney, Doff B.; Hellenbrand, William E.; Zahn, Evan M.; Jones, Thomas K.; Cheatham, John P.; Lock, James E.; Vincent, Julie A.
2014-01-01
Background Transcatheter pulmonary valve placement is an emerging therapy for pulmonary regurgitation and right ventricular outflow tract obstruction in selected patients. The Melody valve was recently approved in the United States for placement in dysfunctional right ventricular outflow tract conduits. Methods and Results From January 2007 to August 2009, 136 patients (median age, 19 years) underwent catheterization for intended Melody valve implantation at 5 centers. Implantation was attempted in 124 patients; in the other 12, transcatheter pulmonary valve placement was not attempted because of the risk of coronary artery compression (n=6) or other clinical or protocol contraindications. There was 1 death from intracranial hemorrhage after coronary artery dissection, and 1 valve was explanted after conduit rupture. The median peak right ventricular outflow tract gradient was 37 mm Hg before implantation and 12 mm Hg immediately after implantation. Before implantation, pulmonary regurgitation was moderate or severe in 92 patients (81% with data); no patient had more than mild pulmonary regurgitation early after implantation or during follow-up (≥1 year in 65 patients). Freedom from diagnosis of stent fracture was 77.8±4.3% at 14 months. Freedom from Melody valve dysfunction or reintervention was 93.5±2.4% at 1 year. A higher right ventricular outflow tract gradient at discharge (P=0.003) and younger age (P=0.01) were associated with shorter freedom from dysfunction. Conclusions In this updated report from the multicenter US Melody valve trial, we demonstrated an ongoing high rate of procedural success and encouraging short-term valve function. All reinterventions in this series were for right ventricular outflow tract obstruction, highlighting the importance of patient selection, adequate relief of obstruction, and measures to prevent and manage stent fracture. Clinical Trial Registration URL: http://www.clinicaltrials.gov. Unique identifier: NCT00740870. PMID:20644013
Holinski, Sebastian; Zhigalov, Konstantin; Zielinski, Christina Barbara; Grubitzsch, Herko
2017-01-01
Purpose: Hemodynamic performance of aortic valve bioprostheses is essential for reliable function and durability. So far, the supra-annularly implanted stentless Sorin Freedom Solo (SFS) demonstrated unsurpassed hemodynamic properties. As contemporary stented and externally mounted pericardial bioprostheses, like the Labcor Dokimos Plus (LDP), also improve hemodynamic performance, these types of valves were compared in this study. Methods: A total of 218 patients, who underwent aortic valve replacement with the LDP or the SFS, were matched retrospectively 1:1 on variables affecting hemodynamic measurements: implanted valve size, age, sex, and body surface area (BSA). With matching tolerance for valve size and gender of 0%, for age and BSA of 5%, 57 patient-pairs were yielded. Operative data, clinical, and hemodynamic outcome were analyzed. Results: Except for slightly higher left ventricular function and lower procedural times in the SFS group, preoperative, operative, and postoperative characteristics of patient-pairs did not differ significantly. Mean pressure gradients, effective orifice areas (EOAs), and indexed EOAs were comparable. Corresponding to valve sizes of 21, 23, 25, and 27 mm, the indexed EOAs of the LDP and SFS prostheses were 1.08 ± 0.33, 0.92 ± 0.19, 0.93 ± 0.24, 0.99 ± 0.13 cm2/m2 and 0.81 ± 0.13, 0.92 ± 0.28, 0.95 ± 0.20, 1.04 ± 0.27 cm2/m2, respectively. Conclusion: Contemporary stented and stentless pericardial bioprostheses showed excellent hemodynamic properties without significant differences in EOAs and indexed EOAs. PMID:28890465
Frey, Daniela; Billinger, Michael; Meier, Pascal; Beslac, Olgica; Grossenbacher, Raphael; Hänni, Beat; Hess, Otto M
2008-12-01
Vascular healing of intracoronary stents has been shown to be delayed in drug-eluting stents (DES) due to the cytotoxic compounds on the stent surface that prevent stent ingrowth and endothelialization. The lack of endothelialization explains the occurrence of late and very late stent thrombosis in DES. In 11 house swines (body weight 38-45 kg), 3 stents were implanted randomly into the 3 large epicardial coronary arteries, namely a bare-metal stent (BMS), a sirolimus-eluting stent with slow-release (SES) and a SES with extended-release (SESXR). Stent length was 18 mm, and stent diameter 3 mm. All stents were of identical design. Animals were followed for 3 (n = 3), 7 (n = 4) and 14 (n = 4) days, respectively. One animal died before implantation due to hyperthermia. On the day of explantation, the animals were euthanized and endothelialization was tested by scanning electron microscopy after drying and sputtering the samples. Endothelial coverage was determined semiquantitatively by 2 observers. Endothelialization was more rapid with BMS and SESXR than SES at 3 and 14 days. At 7 days there were no significant differences between the 2 SES. Endothelialization of intracoronary stents is faster with BMS and SESXR at 3 days than with SES. These differences persist at 14 days, suggesting delayed vascular healing with the slow-release SES.
Process for making electroformed stents
Hines, Richard A.
2000-02-01
This invention is directed to an expandable stent useful for implantation into an artery or the like. The stents are made using electroforming techniques in which an electrically-conductive mandrel is coated with a suitable resist material, after which the resist is exposed to an appropriate light pattern and frequency so as to form a stent pattern in the resist. The mandrel is then electroplated with a suitable stent material. The mandrel is etched away once a sufficient layer of stent material is deposited, leaving a completed stent.
Ghazi, Payam; Haji-Zeinali, Ali-Mohammad
2010-01-01
We describe a case of native coarctation of aorta managed with three self-expandable nitinol stents. After balloon pre-dilation, the first and second stents were dislodged. The coarcted area was successfully treated with the third stent overlapped with the previous stents. During follow up (30 months), the patient was free of complications. It seems that implantation of multiple overlapping self-expandable stents in aortic coarctation patients, if needed, is safe and possible.
Jeličić, Aleksandra; Friedrich, Alwin; Jeremić, Katarina; Siekmeyer, Gerd; Taubert, Andreas
2009-01-01
One of the main issues with the use of nickel titanium alloy (NiTi) implants in cardiovascular implants (stents) is that these devices must be of very high quality in order to avoid subsequent operations due to failing stents. For small stents with diameters below ca. 2 mm, however, stent characterization is not straightforward. One of the main problems is that there are virtually no methods to characterize the interior of the NiTi tubes used for fabrication of these tiny stents. The current paper reports on a robust hybrid actuator for the characterization of NiTi tubes prior to stent fabrication. The method is based on a polymer/hydrogel/magnetic nanoparticle hybrid material and allows for the determination of the inner diameter at virtually all places in the raw NiTi tubes. Knowledge of the inner structure of the raw NiTi tubes is crucial to avoid regions that are not hollow or regions that are likely to fail due to defects inside the raw tube. The actuator enables close contact of a magnetic polymer film with the inner NiTi tube surface. The magnetic signal can be detected from outside and be used for a direct mapping of the tube interior. As a result, it is possible to detect critical regions prior to expensive and slow stent fabrication processes.
Lee, Byoung-Kwon; Kim, Jung-Sun; Lee, Oh-Huyn; Min, Pil-Ki; Yoon, Young-Won; Hong, Bum-Kee; Shin, Dong-Ho; Kang, Tae-Soo; Kim, Byung Ok; Cho, Duk-Kyu; Jeon, Dong Woon; Woo, Sung-Ill; Choi, Seonghoon; Kim, Yong Hoon; Kang, Woong-Chol; Kim, Seunghwan; Kim, Byeong-Keuk; Hong, Myeong-Ki; Jang, Yangsoo; Kwon, Hyuck Moon
2018-03-20
There are few randomised studies concerning the optimal duration of dual antiplatelet therapy (DAPT) for patients who receive a second-generation drug-eluting stent (DES). This trial aimed to investigate the safety of six-month compared with 12-month DAPT maintenance after second-generation DES implantation. A prospective, randomised, multicentre trial was performed at 10 medical centres. The 1,368 patients included in the study received a biolimus-eluting stent (BES) or a zotarolimus-eluting stent (ZES). The primary outcome measured was the composite of major adverse cardiac events (MACE), including cardiac death, myocardial infarction (MI), or ischaemia-driven target lesion revascularisation at the 12-month follow-up. The secondary outcome was the percentage of uncovered struts at six months in 60 patients (30 ZES, 30 BES) using optical coherence tomography (OCT) assessment. Each patient was randomly assigned to six-month (n=684) or 12-month DAPT (n=684). Major adverse cardiac events at 12 months occurred in eight patients (1.2%) in the six-month DAPT group and in four patients (0.6%) in the 12-month DAPT group (risk difference 0.6%; 95% confidence interval [CI]: -0.4-1.6%; p=0.24). The upper 95% CI limit was lower than the pre-specified limit of 4% non-inferiority (p for non-inferiority <0.05). The percentage of uncovered struts was 3.16±4.30% at six months in 60 stents of 60 patients. After second-generation DES implantation, six-month DAPT was not inferior to 12-month DAPT in terms of MACE occurrence over the 12-month follow-up period. OCT examination revealed favourable stent strut coverage at six months after stent implantation.
Haine, Steven; Wouters, Kristien; Miljoen, Hielko; Vandendriessche, Tom; Claeys, Marc; Bosmans, Johan; Vrints, Christiaan
2018-04-01
Since neointima smooth muscle cells (SMC) mainly originate from the vessel wall, we investigated whether atherosclerotic plaque composition influences subsequent in-stent neointima proliferation and restenosis. We performed intravascular ultrasound (IVUS) with virtual histology in 98 patients prior to elective bare-metal stent (BMS) implantation in de novo coronary artery lesions. Virtual histology variables pre-percutaneous coronary intervention (PCI) were related to in-stent neointima proliferation six months after implantation assessed as late luminal loss of 0.88 mm (interquartile range (IQR) 0.37-1.23 mm) on angiography and as maximal percentage area stenosis of 42% (IQR 33-59%) and percentage volume intima hyperplasia of 27% (IQR 20-36%) on IVUS. A ridge-trace based multiple linear regression model was constructed to account for multicollinearity of the virtual histology variables and was corrected for implanted stent length (18 mm, IQR 15-23 mm), stent diameter (3.0 mm, IQR 2.75-3.5 mm) and lesion volume (146 mm³, IQR 80-201 mm³) prior to PCI. Fibrous tissue volume prior to PCI (49 mm³, IQR 30-77 mm³) was significantly and independently related to late luminal loss (p = .038), maximal percentage area stenosis (p = .041) and percentage volume intima hyperplasia (p = .004). Neither absolute nor relative amounts of fibrofatty, calcified or necrotic core tissue appeared related to any of the restenosis parameters. Subgroup analysis after exclusion of acute coronary syndrome (ACS) patients yielded similar results. Lesions with more voluminous fibrotic tissue pre-PCI show more pronounced in-stent neointima proliferation, even after correction for lesion plaque volume.
Daróczi, Tímea; Bor, Renáta; Fábián, Anna; Szabó, Ella; Farkas, Klaudia; Bálint, Anita; Czakó, László; Rutka, Mariann; Szűcs, Mónika; Milassin, Ágnes; Molnár, Tamás; Szepes, Zoltán
2016-02-14
Self-expandable metal and plastic stents can be applied in the palliative endoscopic treatment of patients with unresectable malignant biliary obstruction. The use of metal stentsis recommended if the patient's life expectancy is more than four months. To compare the therapeutic efficacy and cost-effectiveness of metal and plastic stents in the treatment of malignant biliary obstruction. The authors retrospectively enrolled patients who received metal (37 patients) or plastic stent (37 patients). The complication rate, stent patency and cumulative cost of treatment were assessed in the two groups. The complication rate of metal stents was lower (37.84% vs. 56.76%), but the stent patency was higher compared with plastic stents (19.11 vs. 8.29 weeks; p = 0.0041). In the plastic stent group the frequency of hospitalization of patients in context with stent complications (1.18 vs. 2.32; p = 0.05) and the necessity of reintervention for stent dysfunction (17 vs. 27; p = 0.033) were substantially higher. In this group multiple stent implantation raised the stent patency from 7.68 to 10.75 weeks. There was no difference in the total cost of treatment of malignant biliary obstruction between the two groups (p = 0.848). Considering the cost of treatment and the burden of patients the authors recommend self-expandable metal sten timplantation if the life expectancy of patients is more than two months. In short survival cases multiple plastic stent implantation is recommended.
Palliation double stenting for malignant biliary and duodenal obstruction
ZHAO, LIANG; XU, HAITAO; ZHANG, YUBAO
2016-01-01
The surgical management of patients with malignant biliary and duodenal obstruction is complex. Tumor excision is no longer possible in the majority of patients with malignant obstructive jaundice and duodenal obstruction. The aim of the present study was to evaluate the effectiveness of intraluminal dual stent placement in malignant biliary and duodenal obstruction. In total, 20 patients with malignant obstructive jaundice and duodenal obstruction, including 6 with pancreatic carcinoma, 11 with cholangiocarcinoma, 1 with duodenal carcinoma and 2 with abdominal lymph node metastasis, were treated with intraluminal stent placement. Bile duct obstruction with late occurrence of duodenal obstruction was observed in 16 cases, and duodenal obstruction followed by a late occurrence of bile duct obstruction was observed in 3 cases, while, in 1 case, bile duct obstruction and duodenal obstruction occurred simultaneously. After X-ray fluoroscopy revealed obstruction in the bile duct and duodenum, stents were placed into the respective lumens. Percutaneous transhepatic placement was employed for the biliary stent, while the duodenal stent was placed perioraly. The clinical outcomes, including complications associated with the procedures and patency of the stents, were evaluated. The biliary and duodenal stents were successfully implanted in 18 patients and the technical success rate was 90% (18/20). A total of 39 stents were implanted in 20 patients. In 2 cases, duodenal stent placement failed following biliary stent placement. Duodenal obstruction remitted in 15 patients, and 1 patient succumbed to aspiration pneumonia 5 days after the procedure. No severe complications were observed in any other patient. The survival time of the 18 patients was 5–21 months (median, 9.6 months), and 6 of those patients survived for >12 months. The present study suggests that X-ray fluoroscopy-guided intraluminal stent implantation is an effective procedure for the treatment of malignant biliary and duodenal obstruction. PMID:26889267
Gössl, Mario; Johnson, Jonathan N; Hagler, Donald J
2014-04-01
We present the case of a 36-year-old woman with increasing shortness of breath, a new 3/4 diastolic murmur, and a complex history of LV outflow tract obstruction. She has undergone multiple surgeries including the replacement of her old LV apex to ascending aorta conduit with a 20-mm Gore-Tex tube graft, addition of a 24-mm homograft sutured between the conduit and the LV apex, and insertion of a 21-mm Freestyle porcine valve conduit between the Gore-Tex tube graft and allograft at age 23. The current assessment showed a failing Freestyle conduit prosthesis leading to left heart decompensation. Due to substantial surgical risk, the patient underwent successful implantation of a Melody valve into the Gore-Tex tube and exclusion of the failing Freestyle bioprosthesis with a NuMed CP stent in a hybrid procedure. The case nicely illustrates the collaborative potential of cardiovascular surgeons and interventional cardiologists in the new arena of a hybrid operating room. Complex hybrid procedures like the current one, especially those including percutaneous placements of valves, offer therapeutic options for patients that are otherwise too high risk for conventional open heart surgery. Copyright © 2013 Wiley Periodicals, Inc.
The impact of overhead lines for employees with stents
NASA Astrophysics Data System (ADS)
Syrek, P.; Skowron, M.
2017-05-01
The aim of article is to discuss interaction between stents implanted in the body of worker and harmonic magnetic field in the vicinity of electric wires. In last decades, a growing proportion of people has any devices implanted, to list: cardiac pacemakers, cardioverter - defibrillators. Recommendations of International Commision on Non-ionizing Radiation Protection (ICNIRP), and resctrictions imposed in different states, may exlude specific individuals from their duties. The autors focused on the situation, when the employee with stent, works in the immediate vicinity of overhead electric wires, cleaning with dry ice the electric insulators.
Teijink, J A W; van Herwaarden, J A; van den Berg, J C; Overtoom, T C; Moll, F L
2004-06-01
In the treatment of coronary artery disease, peripheral loss of a coronary stent is an unusual complication. We present the case of a patient who suggested that his right leg claudication was caused by a slipped coronary stent 2 years previously. The patient was convinced about this unusual finding based on an airport security check. Examination proved him to be right. However, the ability to detect an object using eddy currents is dependent on the object's permeability and its conductivity. Ferrous (iron) content is not the critical factor. Modern implant materials and processing techniques result in implants that are difficult to magnetize i.e. their permeability is very low. In addition their conductivity is very low. This enables modern implants to escape detection at airports. For this reason the event at the airport, as described by our patient, is considered coincidental.
Xu, Xuan; Li, Dandan; Zhao, Shuyu; Liu, Xicheng; Feng, Zhichun; Ding, Hui
2012-01-01
The aim of this study was to evaluate the use of balloon-expandable metallic stents in the treatment of children with congenital tracheal stenosis in whom conventional therapy has failed. From 2010 to 2011, balloon-expandable metallic stents were implanted into the trachea of eight infants aged 2–20 months in the paediatric intensive care unit. The infants had severe airway obstruction caused by congenital tracheal stenosis. Tracheal stents were placed after intraluminal balloon dilatation of the tracheal stenosis, inserted with balloon catheters and implanted into the desired position bronchoscopically. The stents were 12 to 29 mm long and 4 mm in diameter. Seven children were relieved of airway obstruction after this procedure. However, a child died due to severe sepsis after the placement of bronchial stents. No granulation tissue developed over the stents in any of the children. Stents have been in place for 1–6 months after insertion without any other complication. Balloon-expandable metallic stents are effective in relieving airway obstruction by congenital tracheal stenosis in children. This technique may provide an important remedy for congenital tracheal stenosis in children. PMID:22361127
Haraguchi, Naotsugu; Ikeda, Masataka; Miyake, Masakazu; Yamada, Takuya; Sakakibara, Yuko; Mita, Eiji; Doki, Yuichiro; Mori, Masaki; Sekimoto, Mitsugu
2016-11-01
To clarify the advantages and disadvantages of stenting as a bridge to surgery (BTS) by comparing the clinical features and outcomes of patients who underwent BTS with those of patients who underwent emergency surgery (ES). We assessed technical success, clinical success, surgical procedures, stoma formation, complications, clinicopathological features, and Onodera's prognostic nutritional index (OPNI) in patients who underwent BTS and those who underwent ES. Twenty-six patients underwent stenting, which was successful in 22 (BTS group). The remaining four patients with unsuccessful stenting underwent emergency surgery. A total of 22 patients underwent emergency surgery (ES group). The rates of technical and clinical success were 85.0 and 81.0 %, respectively. The proportion of patients able to be treated by laparoscopic surgery (P = 0.0001) and avoid colostomy (P = 0.0042) was significantly higher in the BTS group. Although the incidence of anastomotic leakage in the two groups was not significantly different, it was significantly reduced by colonoscopic evaluation of obstructive colitis (P = 0.0251). The mean number of harvested lymph nodes (P = 0.0056) and the proportion of D3 lymphadenectomy (P = 0.0241) were significantly greater in the BTS group. Perineural invasion (PNI) was noted in 59.1 and 18.2 % of the BTS group and ES group patients, respectively (P = 0.0053). OPNI and serum albumin decreased significantly after stenting (P = 0.0084). The advantages of stenting as a BTS were that it avoided colostomy and allowed for laparoscopic surgery and lymphadenectomy, whereas its disadvantage lay in the decreased PNI and OPNI levels. A larger study including an analysis of prognosis is warranted.
The use of expandable metallic airway stents for tracheobronchial obstruction in children.
Filler, R M; Forte, V; Fraga, J C; Matute, J
1995-07-01
Expandable metallic angioplasty stents (Palmaz stent) have been implanted in the trachea and/or bronchi of seven children. Three children had severe tracheal stenosis after tracheoplasty for congenital tracheal stenosis repair, and four had tracheomalacia or bronchomalacia with or without vascular compression. The mean age at stenting was 9.7 months (range, 2 to 15 months). Balloon expandable stents were inserted into the trachea or bronchus through a 3.5-mm bronchoscope under fluoroscopic control. Initially a single tracheal stent was used for all patients except for one with obstruction in the trachea and both bronchi, in whom three stents were implanted. Three children had recurrent airway obstruction 1 month later; one was cured with a second stent; one child died 1 year later; and the other is being treated for heart disease. The others have no serious respiratory problems. The stents in all have been in place for 1 to 25 (mean, 11) months. No immediate complications were noted. Early and late bronchoscopy showed incomplete epithelialization of the stent and patches of granulation tissue on it. Two stents were removed bronchoscopically, one at the completion of treatment for tracheomalacia and the other at the time of recurrent airway obstruction. This preliminary experience indicates that expandable metallic stents have a useful role in the treatment of selected lower airway obstructions.
Latib, Azeem; Ferri, Luca; Ielasi, Alfonso; Cosgrave, John; Godino, Cosmo; Bonizzoni, Erminio; Romagnoli, Enrico; Chieffo, Alaide; Valgimigli, Marco; Penzo, Carlo; Carlino, Mauro; Michev, Iassen; Sangiorgi, Giuseppe M; Montorfano, Matteo; Airoldi, Flavio; Colombo, Antonio
2010-06-01
Concerns about the long-term safety of drug-eluting stents (DES) in saphenous vein grafts has become an area of controversy and uncertainty. In this retrospective registry, we compared the outcomes in 127 patients (143 lesions) treated with DES from April 2002 to June 2006 (DES group) with 131 patients (160 lesions) treated with bare-metal stents in the preceding 36 months (bare-metal stent group). End points analyzed were cumulative death, myocardial infarction, and target vessel revascularization at 2 years after stent implantation. The DES group was significantly (P<0.05) more complex with a greater frequency of diabetes (33.1%versus 15.3%), older grafts (11.6+/-5.3 years versus 9.6+/-5.2 years), restenotic lesions (23.8% versus 4.4%), total occlusions (7.7% versus 1.2%), and smaller grafts (3.16+/-0.66 mm versus 3.44+/-0.76 mm) treated with longer stents (34.1+/-25.1 mm versus 22.7+/-11.6 mm). At 2 years, there was no statistical difference in death (8.7% versus 7.8%), myocardial infarction (6.3% versus 9.4%), or target vessel revascularization (19.7% versus 24.2%) between DES and bare-metal stents, respectively. A propensity analysis to adjust for baseline differences suggested that there was no observed association between DES and increased mortality (hazard ratio, 0.72; 95% CI, 0.21 to 2.44; P=0.60) but possibly an association with a reduction in target vessel revascularization (hazard ratio, 0.31; 95% CI, 0.14 to 0.66; P=0.002). Despite being implanted in patients and lesions more complex than the bare-metal stent group, there was no observed association between DES implantation in saphenous vein grafts and an increase in late mortality. DES may maintain their efficacy in reducing revascularization rates in diseased saphenous vein grafts over a 2-year follow-up period.
Piazza, Nicolo; Bleiziffer, Sabine; Brockmann, Gernot; Hendrick, Ruge; Deutsch, Marcus-André; Opitz, Anke; Mazzitelli, Domenico; Tassani-Prell, Peter; Schreiber, Christian; Lange, Rüdiger
2011-07-01
This study sought to review the acute procedural outcomes of patients who underwent transcatheter aortic valve (TAV)-in-surgical aortic valve (SAV) implantation at the German Heart Center, Munich, and to summarize the existing literature on TAV-in-SAV implantation (n = 47). There are several case reports and small case series describing transcatheter aortic valve implantation for a failing surgical aortic valve bioprosthesis (TAV-in-SAV implantation). From January 2007 to March 2011, 20 out of 556 patients underwent a TAV-in-SAV implantation at the German Heart Center Munich. Baseline characteristics and clinical outcome data were prospectively entered into a dedicated database. The mean patient age was 75 ± 13 years, and the mean logistic European System for Cardiac Operative Risk Evaluation and Society of Thoracic Surgeons' Risk Model scores were 27 ± 13% and 7 ± 4%, respectively. Of the 20 patients, 14 had stented and 6 had stentless surgical bioprostheses. Most cases (12 of 20) were performed via the transapical route using a 23-mm Edwards Sapien prosthesis (Edwards Lifesciences, Irvine, California). Successful implantation of a TAV in a SAV with the patient leaving the catheterization laboratory alive was achieved in 18 of 20 patients. The mean transaortic valve gradient was 20.0 ± 7.5 mm Hg. None-to-trivial, mild, and mild-to-moderate paravalvular aortic regurgitation was observed in 10, 6, and 2 patients, respectively. We experienced 1 intraprocedural death following pre-implant balloon aortic valvuloplasty ("stone heart") and 2 further in-hospital deaths due to myocardial infarction. TAV-in-SAV implantation is a safe and feasible treatment for high-risk patients with failing aortic bioprosthetic valves and should be considered as part of the armamentarium in the treatment of aortic bioprosthetic valve failure. Copyright © 2011 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
A Migrated Aortic Stent Graft Causing Erosive Spondylopathy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gestrich, Christopher, E-mail: christopher.gestrich@ukb.uni-bonn.de; Probst, Chris, E-mail: chris.probst@ukb.uni-bonn.de; Wilhelm, Kai, E-mail: kai.wilhelm@ek-bonn.de
We report about a patient presenting with back pain 4 months after an uneventful endovascular implantation of an aortic stent graft. Computed tomography scan revealed a migration of the stent with consecutive endoleakage, kink formation, and movement of the stent toward the spine, which caused destruction of the aortic wall as well as vertebral necrosis. Explantation of the stent and replacement of the native aorta relieved the patient of his symptoms.
Lee, Seung Yul; Shin, Dong Ho; Kim, Jung Sun; Kim, Byeong Keuk; Ko, Young Guk; Choi, Donghoon; Jang, Yangsoo; Hong, Myeong Ki
2017-03-01
To evaluate the effects of sex and anthropometry on clinical outcomes in patients who underwent percutaneous coronary intervention (PCI). From three randomized trials (REal Safety and Efficacy of 3-month dual antiplatelet Therapy following Endeavor zotarolimus-eluting stent implantation, Impact of intraVascular UltraSound guidance on outcomes of Xience Prime stents in Long lesions, Chronic Total Occlusion InterVention with drUg-eluting Stents), we compared 333 pairs of men and women matched by propensity scores, all of whom underwent intravascular ultrasound (IVUS)-guided PCI for complex lesions. For 12 months, the incidence of adverse cardiac events, defined as the composite of cardiac death, target lesion-related myocardial infarction, and target lesion revascularization, was not different between women and men (2.4% vs. 2.4%, p=0.939). Using multivariable Cox's regression analysis, post-intervention minimum lumen area [MLA; hazard ratio (HR)=0.620, 95% confidence interval (CI)=0.423-0.909, p=0.014] by IVUS was a predictor of adverse cardiac events. Height on anthropometry and lesions with chronic total occlusion were significantly related to post-intervention MLA. However, female sex was not independently associated with post-intervention MLA. In an age and sex-adjusted model, patients in the low tertile of height exhibited a greater risk for adverse cardiac events than those in the high tertile of height (HR=6.391, 95% CI=1.160-35.206, p=0.033). Sex does not affect clinical outcomes after PCI for complex lesions. PCI outcomes, however, may be adversely affected by height.
Galassi, Alfredo R; Tomasello, Salvatore D; Costanzo, Luca; Campisano, Maria B; Barrano, Giombattista; Tamburino, Corrado
2011-10-01
Drug-eluting stents showed a better angiographic and clinical outcome in comparison with bare metal stent in chronic total occlusions (CTOs) percutaneous revascularization, however, great concerns still remain regarding the rate of restenosis and reocclusion in comparison with nonocclusive lesions. To evaluate angiographic and clinical outcomes after sirolimus-eluting stent (SES) implantation in the setting of a "real world" series of complex CTOs. From January 2006 to December 2008, 172 consecutive patients with 179 CTO lesions were enrolled into registry. Among these, successful recanalization was obtained in 144 lesions (80.4%) with exclusive SES implantation in 104 lesions. The 9-12 months angiographic follow-up was executed in 85.5% of lesions with evidence of angiographic binary restenosis in 16.8% of lesions. Total stent length and number of stent implanted were recognized as independent predictors of restenosis (odds ratio [OR] 4.7, 95% confidence interval [CI] 1.28-107.09, P = 0.02) and (OR 5.8, 95% CI 1.39-23.55, P = 0.01), respectively.The 2-year clinical follow-up showed rates of target lesion revascularization, non-Q wave myocardial infarction, and total major adverse cardiovascular events (MACEs) of 11.1%, 2%, and 13.1%, respectively. Cox proportional-hazard analysis showed diabetes as independent predictor of MACEs (hazard ratio [HR] 4.832; 95% CI, 0.730-0.861; P = 0.028). Data from this registry demonstrate the long-term efficacy and safety of SES implantation after complex CTOs recanalization. ©2011, Wiley Periodicals, Inc.
Pierson, Daniel; Edick, Jacob; Tauscher, Aaron; Pokorney, Ellen; Bowen, Patrick; Gelbaugh, Jesse; Stinson, Jon; Getty, Heather; Lee, Chee Huei; Drelich, Jaroslaw; Goldman, Jeremy
2012-01-01
Metal stents are commonly used to revascularize occluded arteries. A bioabsorbable metal stent that harmlessly erodes away over time may minimize the normal chronic risks associated with permanent implants. However, there is no simple, low-cost method of introducing candidate materials into the arterial environment. Here, we developed a novel experimental model where a biomaterial wire is implanted into a rat artery lumen (simulating bioabsorbable stent blood contact) or artery wall (simulating bioabsorbable stent matrix contact). We use this model to clarify the corrosion mechanism of iron (≥99.5 wt %), which is a candidate bioabsorbable stent material due to its biocompatibility and mechanical strength. We found that iron wire encapsulation within the arterial wall extracellular matrix resulted in substantial biocorrosion by 22 days, with a voluminous corrosion product retained within the vessel wall at 9 months. In contrast, the blood-contacting luminal implant experienced minimal biocorrosion at 9 months. The importance of arterial blood versus arterial wall contact for regulating biocorrosion was confirmed with magnesium wires. We found that magnesium was highly corroded when placed in the arterial wall but was not corroded when exposed to blood in the arterial lumen for 3 weeks. The results demonstrate the capability of the vascular implantation model to conduct rapid in vivo assessments of vascular biomaterial corrosion behavior and to predict long-term biocorrosion behavior from material analyses. The results also highlight the critical role of the arterial environment (blood vs. matrix contact) in directing the corrosion behavior of biodegradable metals. Copyright © 2011 Wiley Periodicals, Inc.
Rubboli, Andrea; Sciahbasi, Alessandro; Briguori, Carlo; Saia, Francesco; Palmieri, Cataldo; Moroni, Luigi Andrea; Calabrò, Paolo; Leone, Antonio Maria; Franco, Nicoletta; Valgimigli, Marco; Varani, Elisabetta; Santi, Michela; Pasqualini, Paola; Capecchi, Alessandro; Piccalò, Giacomo; Margheri, Massimo; di Pasquale, Giuseppe; Galvani, Marcello; Bolognese, Leonardo; Gonzini, Lucio; Maggioni, Aldo Pietro
2013-04-01
The in-hospital management of patients on warfarin undergoing coronary stent implantation (PCI-S) is variable, and the in-hospital outcome incompletely defined. To determine the adherence to the current recommendations, and the incidence of adverse events, we carried out the prospective, multicenter, observational WARfarin and coronary STENTing (WAR-STENT) registry (ClinicalTrials.gov identifier NCT00722319). All consecutive patients on warfarin undergoing PCI-S at 37 Italian centers were enrolled and followed for 12 months. Outcome measures were: major adverse cardiovascular events (MACE), including cardiovascular death, non-fatal myocardial infarction, need for urgent revascularization, stroke, and venous thromboembolism, and major and minor bleeding. In this paper, we report the in-hospital findings. Out of the 411 patients enrolled, 92% were at non-low (ie, moderate or high) thromboembolic risk. The radial approach and bare-metal stents were used in 61% and 60% of cases, respectively. Drug-eluting stents were essentially reserved to patients with diabetes, which in turn, significantly predicted the implantation of drug-eluting stents (odds ratio [OR], 2.02; 95% confidence interval [CI], 1.29-3.17; P=.002). The in-hospital MACE and major bleeding rates were 2.7% and 2.1%, respectively. At discharge, triple therapy (TT) of warfarin, aspirin, and clopidogrel was prescribed to 76% of patients. Prescription of TT was significantly more frequent in the non-low thromboembolic risk group. Non-low thromboembolic risk, in turn, was a significant predictor of TT prescription (OR, 11.2; 95% CI, 4.83-26.3; P<.0001). In conclusion, real-world warfarin patients undergoing PCI-S are largely managed according to the current recommendations. As a consequence, the risk of in-hospital MACE and major bleedings appears limited and acceptable.
Forgotten/retained double J ureteric stents: A source of severe morbidity in children
Nerli, Rajendra B.; Magdum, Prasad V.; Sharma, Vikas; Guntaka, Ajay Kumar; Hiremath, Murigendra B.; Ghagane, Shridhar
2016-01-01
Background: The increase in the usage of double J (DJ) ureteral stents in the management of a variety of urinary tract disease processes mandates familiarity with these devices, their consequences and their potential complications, which at times can be devastating. We retrospectively reviewed our series of children with forgotten/retained DJ ureteric stents. Materials and Methods: Hospital records of all patients’ <18 years old who underwent removal of forgotten/retained DJ ureteral stent at our hospital were reviewed for age, gender, indication for insertion of DJ stent, duration of stent insertion, radiological images and surgical procedures performed. Results: During the study period, January 2000 to December 2014 (a 15-year period), a total of 14 children underwent removal of forgotten/retained DJ ureteral stent. A combination of extracorporeal shock wave lithotripsy, cystolitholapaxy and percutaneous nephrolithotomy was done to free the DJ stent and extract it. Conclusions: Forgotten/retained stents in children are a source of severe morbidity, additional/unnecessary hospitalisation and definitely financial strain. PMID:27251521
Le Hello, Claire; Morello, Rémy; Lequerrec, Agnès; Duarte, Christine; Riddell, John; Hamon, Martial
2007-01-01
Aim To prospectively determine the role of platelet glycoprotein IIIa (GP IIIa) gene PlA1/PlA2 polymorphism on the long-term clinical outcome in patients with coronary artery disease undergoing coronary stenting. Design and setting Prospective observational study in the University Hospital of Caen (France). Patients and methods 1 111 symptomatic consecutive Caucasian patients treated with percutaneous coronary intervention including stent implantation underwent genotyping for GP IIIa PlA1/A2. Main outcome measures Long-term clinical outcome in terms of the rate of major adverse cardiac events (MACE, ie death from any cause, non-fatal Q wave or non Q wave myocardial infarction, and need for coronary revascularisation) was obtained and subsequently stratified according to the GP IIIa PlA1/A2 polymorphism. Results Three groups of patients were determined according to the GP IIIa PlA1/A2 polymorphism (71.6% had the A1/A1, 25.8% had the A1/A2 and 2.6% had the A2/A2 genotype). These three groups were comparable for all clinical characteristics including sex ratio, mean age, vascular risk factors, previous coronary events, baseline angiographic exam, indication for the percutaneous coronary intervention and drug therapy). The incidence of MACE was similar in these 3 groups of patients during a mean follow-up period of 654+/-152 days. Independent risk factors for MACE were a left ventricular ejection fraction < 40%, absence of treatment with a beta-blocker and absence of treatment with an angiotensin converting enzyme inhibitor during follow-up. Conclusion The GP IIIa PlA1/A2 polymorphism does not influence the clinical long-term outcome in patients with symptomatic coronary disease undergoing percutaneous coronary intervention with stent implantation. PMID:18021403
Kim, Hyun Kuk; Jeong, Myung Ho; Lim, Kyung Seob; Kim, Jung Ha; Lim, Han Chul; Kim, Min Chul; Hong, Young Joon; Kim, Sung Soo; Park, Keun-Ho; Chang, Kyoung-Sig
2017-08-01
Several investigations have been conducted to evaluate the off-target effects of ticagrelor. The aim of the present study was to evaluate the off-target effects of ticagrelor such as neointimal formation and endothelial function after drug-eluting stent implantation in a porcine restenosis model. A total of 30 pigs were randomly allocated based on the following P2Y 12 inhibitor: (1) clopidogrel 300mg loading plus 75mg maintenance (n=10); (2) prasugrel 60mg loading plus 10mg maintenance (n=10); (3) ticagrelor 180mg loading plus 180mg maintenance (n=10). In each group, zotarolimus-eluting stents were implanted in the proximal portion of the left anterior descending artery and left circumflex artery. One month after stenting, the animals underwent follow-up angiography, endothelial function assessment, optical coherence tomography (OCT) and histopathological analysis. Regarding vasomotor responses to acetylcholine infusion, there were significant vasoconstrictions to maximal acetylcholine infusion in the clopidogrel and prasugrel group compared with those in the ticagrelor group. The mean neointimal area were significantly lower in the ticagrelor group (1.0±0.3 by OCT, 0.9±0.3 by histology), than in the clopidogrel (1.8±0.7, p=0.003, 1.6±0.8, p=0.030) and prasugrel (1.8±0.5, p=0.001, 1.5±0.5, p=0.019) groups. Percentages of moderate to dense peri-strut inflammatory cell infiltration were significantly lower in the ticagrelor group (9.0%) compared with the clopidogrel (17.3%, p<0.001) and prasugrel groups (15.7%, p=0.002). There were no significant differences in all findings between clopidogrel and prasugrel groups. Compared to clopidogrel and prasugrel, ticagrelor reduced neointimal formation, endothelial dysfunction, and peri-strut inflammation. Copyright © 2017 Elsevier B.V. All rights reserved.
Demonstration of bacterial biofilms in culture-negative silicone stent and jones tube.
Parsa, Kami; Schaudinn, Christoph; Gorur, Amita; Sedghizadeh, Parish P; Johnson, Thomas; Tse, David T; Costerton, John W
2010-01-01
To demonstrate the presence of bacterial biofilms on a dacryocystorhinostomy silicone stent and a Jones tube. One dacryocystorhinostomy silicone stent and one Jones tube were removed from 2 patients who presented with an infection of their respective nasolacrimal system. Cultures were obtained, and the implants were processed for scanning electron microscopy and confocal laser scanning microscopy, advanced microscopic methods that are applicable for detection of uncultivable biofilm organisms. Routine bacterial cultures revealed no growth, but bacterial biofilms on outer and inner surfaces of both implants were confirmed by advanced microscopic techniques. To the authors' knowledge, this is the first article that documents the presence of biofilms on a Crawford stent or a Jones tube on patients who presented with infections involving the nasolacrimal system. Although initial cultures revealed absence of any bacterial growth, confocal laser scanning microscopy and scanning electron microscopy documented bacterial colonization. Clinicians should consider the role of biofilms and the limitation of our standard culturing techniques while treating patients with device- or implant-related infections.
Sirolimus versus paclitaxel coronary stents in clinical practice.
Millauer, Niklas; Jüni, Peter; Hofmann, Alexandra; Wandel, Simon; Bhambhani, Anupham; Billinger, Michael; Urwyler, Niklaus; Wenaweser, Peter; Hellige, Gerrit; Räber, Lorenz; Cook, Stéphane; Vogel, Rolf; Togni, Mario; Seiler, Christian; Meier, Bernhard; Windecker, Stephan
2011-01-01
We aimed at comparing the long term clinical outcome of SES and PES in routine clinical practice. Although sirolimus-eluting stents (SES) more effectively reduce neointimal hyperplasia than paclitaxel-eluting stents (PES), uncertainty prevails whether this difference translates into differences in clinical outcomes outside randomized controlled trials with selected patient populations and protocol-mandated angiographic follow-up. Nine hundred and four consecutive patients who underwent implantation of a drug-eluting stent between May 2004 and February 2005: 467 patients with 646 lesions received SES, 437 patients with 600 lesions received PES. Clinical follow-up was obtained at 2 years without intervening routine angiographic follow-up. The primary endpoint was a composite of death, myocardial infarction (MI), or target vessel revascularization (TVR). At 2 years, the primary endpoint was less frequent with SES (12.9%) than PES (17.6%, HR = 0.70, 95% CI 0.50-0.98, P = 0.04). The difference in favor of SES was largely driven by a lower rate of target lesion revascularisation (TLR; 4.1% vs. 6.9%, P = 0.05), whereas rates of death (6.4% vs. 7.6%, P = 0.49), MI (1.9% vs. 3.2%, P = 0.21), or definite stent thrombosis (0.6% vs. 1.4%, P = 0.27) were similar for both stent types. The benefit regarding reduced rates of TLR was significant in nondiabetic (3.6% vs. 7.1%, P = 0.04) but not in diabetic patients (5.6% vs. 6.1%, P = 0.80). SES more effectively reduced the need for repeat revascularization procedures than PES when used in routine clinical practice. The beneficial effect is maintained up to 2 years and may be less pronounced in diabetic patients. Copyright © 2010 Wiley-Liss, Inc.
Spreen, Marlon; Vink, Ted; Knippenberg, Bob; Reekers, Jim; van Dijk, Lukas; Wever, Jan; van Eps, Randolph; van Overhagen, Hans
2014-08-01
In many patients with critical limb ischemia (CLI), transfemoral endovascular recanalization is the preferred treatment. Transpopliteal treatment may be used in patients with inaccessible groins. This retrospective study regards transpopliteal stenting of superficial femoral artery (SFA) occlusions using a 4F system. Eleven patients (4 male and 7 female [mean age 77 years]) underwent 12 attempts of transpopliteal recanalization of long SFA occlusions (Trans-Atlantic InterSociety Consensus B through D). All patients had CLI (Rutherford 4 to 6) and were nonoperable due to poor general condition. Indications for transpopliteal access were proximal/flush SFA occlusions (n = 5), failure of antegrade recanalization (n = 4), infected femoral-femoral crossover bypass (n = 2), and occlusion of both the native SFA and the femoral-popliteal bypass (n = 1). The popliteal artery was punctured under ultrasound guidance. Occlusions were recanalized subintimally, and 4F compatible stents were implanted. Technical success rate (<30 % residual stenosis) was achieved in 83 % of cases. In two patients, stent dislocation occurred while the sheath was removed. One arteriovenous fistula was successfully treated with additional stenting. During 6-month follow-up, there were no major amputations, and three patients died from nonrelated causes. Fifty percent of patients alive after 6 months improved to Rutherford score ≤3. The duplex restenosis (>50 %) rate at 6 months was 50 %. Transpopliteal primary stenting of complex SFA lesions in CLI for a temporary bypass is now technically feasible using a 4F system. Technical results are promising. Clinical results after 6 months are acceptable when taking into consideration that this approach may be the last option for limb salvage.
Ishihara, Takayuki; Iida, Osamu; Fujita, Masashi; Masuda, Masaharu; Okamoto, Shin; Nanto, Kiyonori; Kanda, Takashi; Tsujimura, Takuya; Sunaga, Akihiro; Awata, Masaki; Nanto, Shinsuke; Uematsu, Masaaki
2018-04-01
Whether arterial repair following implantation of drug-eluting stents (DES) of the second generation differs among stent types remains unknown. We examined 41 DES placed in 28 patients (age 72 ± 7 years, male 89%) presenting with stable angina pectoris due to de novo lesions in native coronary arteries. Coronary angioscopy was performed 4 ± 1 months after stent implantation. Patients were divided into two groups based on the DES types: 22 cobalt-chrome everolimus-eluting stents (CoCr-EES) in 13 patients and 19 slow-release zotarolimus-eluting stents (R-ZES) in 15 patients. Neointimal coverage (NIC) was graded as: grade 0, stent struts exposed; grade 1, struts bulging into the lumen, although covered; grade 2, struts embedded in the neointima, but translucent; grade 3, struts fully embedded and invisible. NIC was defined as heterogeneous when the NIC grade variation was ≥1. Presence of thrombus was also investigated. Distribution of dominant NIC grade (CoCr-EES: grade 0, 9%; grade 1, 77%; grade 2, 9%; grade 3, 5%; R-ZES: grade 0, 16%; grade 1: 47%; grade 2, 37%; grade 3, 0%, P = 0.38) and heterogeneity of NIC (P = 0.43) were similar between CoCr-EES and R-ZES groups. Existence of thrombus was not significantly different in CoCr-EES and R-ZES (18 versus 42%, P = 0.17). Arterial repair occurred without significant differences between CoCr-EES and R-ZES 4 months after implantation.
Leibowitz, David; Cohen, Maurice; Planer, David; Mosseri, Morris; Rott, David; Lotan, Chaim; Weiss, A Teddy
2006-04-15
Previous studies have shown a high incidence of cardiovascular complications when noncardiac surgery (NCS) is performed after coronary stenting. No study has compared the outcomes of NCS after stenting compared with percutaneous transluminal coronary angioplasty (PTCA) alone. The records of all patients who underwent NCS within 3 months of percutaneous coronary intervention at our institution were reviewed for adverse clinical events with the end points of acute myocardial infarction, major bleeding, and death < or = 6 months after NCS. A total of 216 consecutive patients were included in the study. Of these, 122 (56%) underwent PTCA and 94 (44%) underwent stenting. A total of 26 patients (12%) died, 13 in the stent group (14%) and 13 in the PTCA group (11%), a nonsignificant difference. The incidence of acute myocardial infarction and major bleeding was 7% and 16% in the stent group and 6% and 13% in the PTCA group (p = NS), respectively. Significantly more events occurred in the 2 groups when NCS was performed within 2 weeks of percutaneous coronary intervention. In conclusion, our study has demonstrated high rates of perioperative morbidity and mortality after NCS in patients undergoing PTCA alone, as well as stenting. These findings support the current guidelines regarding the risk of NCS after stenting but suggest they be extended to PTCA as well.
In vivo response of AZ31 alloy as biliary stents: a 6 months evaluation in rabbits
Liu, Yang; Zheng, Shengmin; Li, Nan; Guo, Huahu; Zheng, Yufeng; Peng, Jirun
2017-01-01
Mg-based metallic materials have been making continuing progress as vascular stents. However, the research of Mg-based materials as non-vascular stents is still at its primary stage. AZ31 stents hereby were implanted into the common bile duct of rabbits for 6 months. The results revealed an existence of 93.82 ± 1.36% and 30.89 ± 2.46% of the original volume after 1 and 3 month, respectively. Whole blood tests indicated an inflammation decreasing to normal level after 3 month implantation. A benign host response was observed via H&E staining. Nonuniform corrosion at the two ends of the stents was observed and considered the results of flow or local inflammation. Moreover, the application of Mg-based materials for different stenting treatment were reviewed and compared. Esophagus was hypothesized most destructive, whilst blood vessel and bile duct considered similar and less destructive. Trachea and nasal cavity were thought to be mildest. PMID:28084306
Current State of Bioabsorbable Polymer-Coated Drug-Eluting Stents
Akinapelli, Abhilash; Chen, Jack P.; Roy, Kristine; Donnelly, Joseph; Dawkins, Keith; Huibregtse, Barbara; Hou, Dongming
2017-01-01
Drug-eluting stents (DES) have been shown to significantly reduce clinical and angiograph-ic restenosis compared to bare metal stents (BMS). The polymer coatings on DES elute antiproliferative drugs to inhibit intimal proliferation and prevent restenosis after stent implantation. Permanent poly-mers which do not degrade in vivo may increase the likelihood of stent-related delayed arterial healing or polymer hypersensitivity. In turn, these limitations may contribute to an increased risk of late clinical events. Intuitively, a polymer which degrades after completion of drug release, leaving an inert metal scaffold in place, may improve arterial healing by removing a chronic source of inflammation, neoath-erosclerosis, and/or late thrombosis. In this way, a biodegradable polymer may reduce late ischemic events. Additionally, improved healing after stent implantation could reduce the requirement for long-term dual antiplatelet therapy and the associated risk of bleeding and cost. This review will focus on bioabsorbable polymer-coated DES currently being evaluated in clinical trials.
In vivo response of AZ31 alloy as biliary stents: a 6 months evaluation in rabbits
NASA Astrophysics Data System (ADS)
Liu, Yang; Zheng, Shengmin; Li, Nan; Guo, Huahu; Zheng, Yufeng; Peng, Jirun
2017-01-01
Mg-based metallic materials have been making continuing progress as vascular stents. However, the research of Mg-based materials as non-vascular stents is still at its primary stage. AZ31 stents hereby were implanted into the common bile duct of rabbits for 6 months. The results revealed an existence of 93.82 ± 1.36% and 30.89 ± 2.46% of the original volume after 1 and 3 month, respectively. Whole blood tests indicated an inflammation decreasing to normal level after 3 month implantation. A benign host response was observed via H&E staining. Nonuniform corrosion at the two ends of the stents was observed and considered the results of flow or local inflammation. Moreover, the application of Mg-based materials for different stenting treatment were reviewed and compared. Esophagus was hypothesized most destructive, whilst blood vessel and bile duct considered similar and less destructive. Trachea and nasal cavity were thought to be mildest.
Ma, Jian; Yang, Weiwei; Singh, Manpreet; Peng, Tianqing; Fang, Ningyuan; Wei, Meng
2011-01-01
In the treatment of chronic total occlusions (CTOs), some uncertainty exists regarding the effect of drug-eluting stents (DESs) compared with the effects of bare mental stents (BMSs). We reviewed outcomes of DES vs. BMS implantation for CTO lesions, to evaluate the risk-benefit ratio of DES implantation. Relevant studies of long-term clinical outcomes or angiographic outcomes of both BMS and DES implantation were examined. The primary endpoint comprised major adverse cardiovascular events (MACEs), including all-cause deaths, myocardial infarctions (MIs), and target lesion revascularizations (TLRs). A fixed-effect model and random-effect model were used to analyze the pooling results. Ten studies were included according to the selection criteria. Eight were nonrandomized controlled trials, and two consisted of a randomized controlled comparison between DES and BMS implantation. No significant difference was evident for in-hospital MACE rates between the two groups (odds ratio [OR], 1.07; 95% confidence interval [CI], .53 to 2.13), but the long-term MACE rates in the DES group were significantly lower than in the BMS group (OR, .22; 95% CI, .13 to .38; P < .00001). The rates of stent restenosis and reocclusions were also significantly lower in the DES group (OR, .14; 95% CI, .09 to .20; and OR, .23; 95% CI, .12 to .41, respectively). Implantation of the DES improves long-term angiographic and clinical outcomes compared with BMS in the treatment of CTO lesions. Copyright © 2011 Elsevier Inc. All rights reserved.
Kitabata, Hironori; Loh, Joshua P; Pendyala, Lakshmana K; Omar, Alfazir; Ota, Hideaki; Minha, Sa'ar; Magalhaes, Marco A; Torguson, Rebecca; Chen, Fang; Satler, Lowell F; Pichard, Augusto D; Waksman, Ron
2014-04-01
We aimed to compare neointimal tissue characteristics between bare-metal stents (BMS) and drug-eluting stents (DES) at long-term follow-up using optical coherence tomography (OCT) and virtual histology intravascular ultrasound (VH-IVUS). Neoatherosclerosis in neointima has been reported in BMS and in DES. Thirty patients with 36 stented lesions [BMS (n=17) or DES (n=19)] >3years after implantation were prospectively enrolled. OCT and VH-IVUS were performed and analyzed independently. Stents with ≥70% diameter stenosis were excluded. The median duration from implantation was 126.0months in the BMS group and 60.0months in the DES group (p <0.001). Lipid-laden intima (58.8% vs. 42.1%, p=0.317), thrombus (17.6% vs. 5.3%, p=0.326), and calcification (35.3% vs. 26.3%, p=0.559) did not show significant differences between BMS and DES. When divided into 3 time periods, the cumulative incidence of lipid-laden neointima from >3years to <9years was similar between BMS and DES (42.9% vs. 42.1%, p=1.000). Furthermore, it continued to gradually increase over time in both groups. OCT-derived thin-cap fibroatheroma (TCFA) was observed in 17.6% of BMS- and 5.3% of DES-treated lesions (p=0.326). No stents had evidence of intimal disruption. The percentage volume of necrotic core (16.1% [9.7, 20.3] vs. 9.7% [7.0, 16.5], p=0.062) and dense calcium (9.5% [3.8, 13.6] vs. 2.7% [0.4, 4.9], p=0.080) in neointima tended to be greater in BMS-treated lesions. Intra-stent VH-TCFA (BMS vs. DES 45.5% vs. 18.2%, p=0.361) did not differ significantly. At long-term follow-up beyond 3 years after implantation, the intra-stent neointimal tissue characteristics appeared similar for both BMS and DES. Copyright © 2014 Elsevier Inc. All rights reserved.
Price, Matthew J; Saito, Shigeru; Shlofmitz, Richard A; Spriggs, Douglas J; Attubato, Michael; McLaurin, Brent; Popma Almonacid, Alexandra; Brar, Sandeep; Liu, Minglei; Moe, Elizabeth; Mehran, Roxana
2017-07-24
The aim of this study was to explore the safety and efficacy of a dedicated drug-eluting stent for the treatment of coronary lesions with very small reference vessel diameter (RVD). Smaller RVD is associated with increased risk for restenosis and target lesion failure (TLF) after stent implantation. This was a prospective, single-arm, multicenter trial of the Resolute Onyx 2.0-mm zotarolimus-eluting stent. The primary endpoint was 12-month TLF, which was compared with a pre-specified performance goal. Subjects with stable or unstable angina or ischemia, target lesions ≤27 mm in length, and RVD ≥2.0 and <2.25 mm were eligible for enrollment. A subset of subjects underwent follow-up angiography at 13 months post-procedure. A total of 101 subjects with 104 lesions were enrolled. The mean age was 67.3 ± 9.6 years, 47% of subjects had diabetes, the mean lesion length was 12.6 ± 6.3 mm, and the mean RVD was 1.91 ± 0.26 mm. The rate of TLF at 12 months was 5.0%, fulfilling the pre-specified performance goal of 19% (p < 0.001). The rates of target lesion revascularization and target vessel myocardial infarction were 2.0% and 3.0%, respectively. There were no episodes of stent thrombosis. In-stent late lumen loss was 0.26 ± 0.48 mm, and the rate of binary restenosis was 12.0%. In this first report of a drug-eluting stent with a dedicated size to treat lesions with RVD <2.25 mm, the Resolute Onyx 2.0-mm zotarolimus-eluting stent was associated with a low rate of TLF and late lumen loss, without a signal for stent thrombosis. This novel-sized drug-eluting stent appears to be a feasible option for the treatment of coronary lesions in extremely small vessels. (Medtronic Resolute Onyx 2.0 mm Clinical Study; NCT02412501). Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.
Kokkinidis, Damianos G; Jeon-Slaughter, Haekyung; Khalili, Houman; Brilakis, Emmanouil S; Shammas, Nicolas W; Banerjee, Subhash; Armstrong, Ehrin J
2018-06-01
With growing use of drug-coated balloons (DCB) for femoropopliteal (FP) artery interventions, there is limited information on rates of real-world adjunctive stent use and its association with short and long-term outcomes. We report on 225 DCB treated FP lesions in 224 patients from the Excellence in Peripheral Artery Disease (XLPAD) registry (NCT01904851) between 2014 and 2016. Cochran-Mantel-Haenszel and Wilcoxon rank sum statistics were used to compare stented (planned or 'bail-out') versus non-stented DCB treated lesions. Stents were implanted in 31% of FP DCB interventions. Among the 70 stents implanted, 46% were for 'bail-out' indications and 54% were planned. Lesions treated with stents were longer (mean 150 mm vs 100 mm; p < 0.001) and less likely to be in-stent restenosis lesions (10% vs 28%; p=0.003). Stenting was significantly more frequent in complex FP lesions, including chronic total occlusions (66% vs 34%; p < 0.001). For bail-out stenting, interwoven nitinol stents were the most common type (50%) followed by drug-eluting stents (34%) and bare-metal stents (22%). There were no differences in peri-procedural complication rates or 12-month target limb revascularization rates (18.6% vs 11.6%; p=0.162) or 12-month amputation rates (11.4% vs 11%; p=0.92) between lesions where adjunctive stenting was used versus lesions without adjunctive stenting, respectively. In conclusion, in a contemporary 'real-world' adjudicated multicenter US registry, adjunctive stenting was necessary in nearly a third of the lesions, primarily for the treatment of more complex FP lesions, with similar short and intermediate-term clinical outcomes compared with non-stented lesions.
Surgical stent planning: simulation parameter study for models based on DICOM standards.
Scherer, S; Treichel, T; Ritter, N; Triebel, G; Drossel, W G; Burgert, O
2011-05-01
Endovascular Aneurysm Repair (EVAR) can be facilitated by a realistic simulation model of stent-vessel-interaction. Therefore, numerical feasibility and integrability in the clinical environment was evaluated. The finite element method was used to determine necessary simulation parameters for stent-vessel-interaction in EVAR. Input variables and result data of the simulation model were examined for their standardization using DICOM supplements. The study identified four essential parameters for the stent-vessel simulation: blood pressure, intima constitution, plaque occurrence and the material properties of vessel and plaque. Output quantities such as radial force of the stent and contact pressure between stent/vessel can help the surgeon to evaluate implant fixation and sealing. The model geometry can be saved with DICOM "Surface Segmentation" objects and the upcoming "Implant Templates" supplement. Simulation results can be stored using the "Structured Report". A standards-based general simulation model for optimizing stent-graft selection may be feasible. At present, there are limitations due to specification of individual vessel material parameters and for simulating the proximal fixation of stent-grafts with hooks. Simulation data with clinical relevance for documentation and presentation can be stored using existing or new DICOM extensions.
Di Dedda, Giovanni; Mirabile, Cristian
2017-01-01
We describe the implantation of an absorbable, custom-made stent of polydioxanone to treat tracheomalacia in a 5-month-old patient with extrinsic compression by a double aortic arch. The use of an absorbable, oversized stent treated the tracheal collapse caused by vascular compression, avoided removal procedures, and allowed the infant's growth. The use of an oversized stent prevented stent migration and gave minimal problems of granulation.
Saxena, Payal; Diehl, David L; Kumbhari, Vivek; Shieh, Frederick; Buscaglia, Jonathan M; Sze, Wilson; Kapoor, Sumit; Komanduri, Srinadh; Nasr, John; Shin, Eun Ji; Singh, Vikesh; Lennon, Anne Marie; Kalloo, Anthony N; Khashab, Mouen A
2015-11-01
Endoscopic therapy is considered first line for management of benign biliary strictures (BBSs). Placement of plastic stents has been effective but limited by their short-term patency and need for repeated procedures. Fully covered self-expandable metallic stents (FCSEMSs) offer longer-lasting biliary drainage without the need for frequent exchanges. The aim of this study was to assess the efficacy and safety of FCSEMS in patients with BBS. A retrospective review of all patients who underwent ERCP and FCSEMS placement at five tertiary referral US hospitals was performed. Stricture resolution and adverse events related to ERCP and/or stenting were recorded. A total of 123 patients underwent FCSEMS placement for BBS and 112 underwent a subsequent follow-up ERCP. The mean age was 62 years (±15.6), and 57% were males. Stricture resolution occurred in 81% of patients after a mean of 1.2 stenting procedures (mean stent dwell time 24.4 ± 2.3 weeks), with a mean follow-up of 18.5 months. Stricture recurrence occurred in 5 patients, and 3 patients required surgery for treatment of refractory strictures. Stent migration (9.7%) was the most common complication, followed by stent occlusion (4.9%), cholangitis (4.1%), and pancreatitis (3.3%). There was one case of stent fracture during removal, and one stent could not be removed. There was one death due to cholangitis. Majority of BBS can be successfully managed with 1-2 consecutive FCSEMS with stent dwell time of 6 months.
Carotid Endarterectomy and Carotid Artery Stenting in the US Medicare Population, 1999-2014
Jones, Michael R.; Leifheit, Erica C.; Sheffet, Alice J.; Howard, George; Lal, Brajesh K.; Howard, Virginia J.; Wang, Yun; Curtis, Jeptha; Brott, Thomas G.
2017-01-01
Importance Carotid endarterectomy and carotid artery stenting are the leading approaches to revascularization for carotid stenosis, yet contemporary data on trends in rates and outcomes are limited. Objective To describe US national trends in performance and outcomes of carotid endarterectomy and stenting among Medicare beneficiaries from 1999 to 2014. Design, Setting, and Participants Serial cross-sectional analysis of Medicare fee-for-service beneficiaries aged 65 years or older from 1999 to 2014 using the Medicare Inpatient and Denominator files. Spatial mixed models adjusted for age, sex, and race were fit to calculate county-specific risk-standardized revascularization rates. Mixed models were fit to assess trends in outcomes after adjustment for demographics, comorbidities, and symptomatic status. Exposures Carotid endarterectomy and carotid artery stenting. Main Outcomes and Measures Revascularization rates per 100 000 beneficiary-years of fee-for-service enrollment, in-hospital mortality, 30-day stroke or death, 30-day stroke, myocardial infarction, or death, 30-day all-cause mortality, and 1-year stroke. Results During the study, 937 111 unique patients underwent carotid endarterectomy (mean age, 75.8 years; 43% women) and 231 077 underwent carotid artery stenting (mean age, 75.4 years; 49% women). There were 81 306 patients who underwent endarterectomy in 1999 and 36 325 in 2014; national rates per 100 000 beneficiary-years decreased from 298 in 1999-2000 to 128 in 2013-2014 (P < .001). The number of patients who underwent stenting ranged from 10 416 in 1999 to 22 865 in 2006 (an increase per 100 000 beneficiary-years from 40 in 1999-2000 to 75 in 2005-2006; P < .001); by 2014, there were 10 208 patients who underwent stenting and the rate decreased to 38 per 100 000 beneficiary-years (P < .001). Outcomes improved over time despite increases in vascular risk factors (eg, hypertension prevalence increased from 67% to 81% among patients who underwent endarterectomy and from 61% to 70% among patients who underwent stenting) and the proportion of symptomatic patients (all P < .001). There were adjusted annual decreases in 30-day ischemic stroke or death of 2.90% (95% CI, 2.63% to 3.18%) among patients who underwent endarterectomy and 1.13% (95% CI, 0.71% to 1.54%) among patients who underwent stenting; an absolute decrease from 1999 to 2014 was observed for endarterectomy (1.4%; 95% CI, 1.2% to 1.5%) but not stenting (−0.1%; 95% CI, −0.5% to 0.4%). Rates for 1-year ischemic stroke decreased after endarterectomy (absolute decrease, 3.5% [95% CI, 3.2% to 3.7%]; adjusted annual decrease, 2.17% [95% CI, 2.00% to 2.34%]) and stenting (absolute decrease, 1.6% [95% CI, 1.2% to 2.1%]; adjusted annual decrease, 1.86% [95% CI, 1.45%-2.26%]). Additional improvements were noted for in-hospital mortality, 30-day stroke, myocardial infarction, or death, and 30-day all-cause mortality as well as within demographic subgroups. Conclusions and Relevance Among fee-for-service Medicare beneficiaries, the performance of carotid endarterectomy declined from 1999 to 2014, whereas the performance of carotid artery stenting increased until 2006 and then declined from 2007 to 2014. Outcomes improved despite increases in vascular risk factors. PMID:28975306
Covered stent to exclude intravascular thrombus.
Liistro, Francesco; Stankovic, Goran; Di Mario, Carlo; Montorfano, Matteo; Briguori, Carlo; Colombo, Antonio
2002-04-01
To describe the utility of stent-graft implantation to avoid distal embolization from a large thrombus-containing lesion. A 67-year-old man was evaluated for recent onset of disabling left leg claudication. Angiography disclosed a mobile lobular mass occluding the left common iliac artery; irregular staining suggested an atherothrombotic lesion. Through a percutaneous ipsilateral access and an 8-F sheath, a balloon-expandable Jostent peripheral stent-graft was positioned with the distal edge immediately proximal to the internal iliac artery ostium. A prominent "waist" at the center of the balloon confirmed entrapment of the thrombotic mass. Completion angiography showed an optimal result with no residual stenosis or evidence of distal embolization. At 6-month follow-up, the patient was asymptomatic with angiographically documented luminal patency and no evidence of in-stent stenosis. Stent-graft implantation appears a viable treatment alternative for thrombus-containing lesions, particularly when the thrombotic material is localized or is in a large vessel.
Ishiwatari, Hirotoshi; Hayashi, Tsuyoshi; Ono, Michihiro; Sato, Tsutomu; Kato, Junji
2013-05-01
Plastic stent (PS) occlusion occurs as a result of bacterial adherence to the stent's inner wall. To retain the bacteriological barrier, placing a PS above the sphincter of Oddi ('inside stent') has been investigated. We designed a new PS (inside stent with thread [IT] stent) with attachable nylon thread for use as an inside stent and for easy retrieval. The present study evaluated the IT stent's technical feasibility and efficacy for malignant hilar biliary obstruction. A total of 26 consecutive patients with unresectable malignant hilar biliary obstruction underwent placement of IT stents from August 2007 to February 2011. IT stents were placed across the strictures without sphincterotomy to achieve bilateral drainage. The overall technical success rate of the IT stent was 100% for one session. Multiple IT stents were inserted in 25 cases(two stents in 15 patients, three stents in 10 patients). No stent-related early complications occurred. The functional success rate was 92% (24/26). The rate of reintervention because of stent malfunction was 50% (13/26). In all 16 patients who underwent stent removal, IT stents were easily retrieved using the nylon thread. According to Kaplan-Meier analysis, the median stent patency period was 136 days. IT stents for endoscopic placement above the sphincter of Oddi can be used safely and effectively for malignant hilar biliary obstruction. © 2013 The Authors. Digestive Endoscopy © 2013 Japan Gastroenterological Endoscopy Society.
Kurata, Naoya; Iida, Osamu; Shiraki, Tatsuya; Fujita, Masashi; Masuda, Masaharu; Okamoto, Shin; Ishihara, Takayuki; Nanto, Kiyonori; Kanda, Takashi; Sunaga, Akihiro; Tsujimura, Takuya; Takahara, Mitsuyoshi; Mano, Toshiaki
2018-04-25
Although stent-to-vessel (S/V) diameter ratio has been described as a restenotic factor after superficial femoral artery (SFA) stenting, the reference vessel diameter is commonly measured distally at a healthy site. It remains unclear whether S/V ratio assessed at the lesion site would be more predictive than that assessed distally at a healthy site.Methods and Results:A total of 117 patients (mean age, 73±7 years; 74% male) who underwent successful nitinol stent implantation in SFA lesions (mean lesion length, 172±104 mm) on intravascular ultrasound (IVUS) were retrospectively analyzed. S/V ratio at the proximal and distal healthy site, and at the smallest lesion site, was evaluated on IVUS. One-year restenosis predictors were evaluated on multivariate analysis. Mean S/V diameter ratio on IVUS at proximal and distal healthy sites, and at the lesion site, was 0.98±0.11, 1.02±0.11 and 1.15±0.16, respectively. One-year primary patency was 77%. On multivariate analysis, lesion length (OR, 1.06 per 10-mm increment; P=0.046) and S/V ratio measured at the lesion site (OR, 1.34 per 0.1 increment; P=0.032), but not that at the distal healthy site (OR, 1.05 per 0.1 increment; P=0.705), were significantly associated with 1-year restenosis. S/V ratio assessed on IVUS at the lesion site, but not at the distal healthy site, was independently associated with 1-year restenosis after SFA stenting.
Song, Min; Song, Ho-Young; Kim, Jin Hyoung; Park, Jung-Hoon; Jung, Hwoon-Yong; Kim, Jong-Hoon; Kim, Sung-Bae
2011-09-01
To retrospectively evaluate the incidence, predictive factors, and interventional management of food impaction after expandable metallic stent placement in patients with obstruction of the esophagus or upper gastrointestinal tract caused by benign or malignant disease. Between March 1993 and March 2010, 1,360 patients (1,029 men, 331 women; age range, 21-89 y; mean age, 61 y) underwent fluoroscopically guided stent placement for dysphagia caused by esophageal or gastrointestinal tract strictures. Five types of covered expandable metal stents were used, including four types of esophageal stents (types A-D) and one type of gastroduodenal stent (type E), with types A, B, C, D, and E stents used in 180, 60, 90, 432, and 598 patients, respectively. Multivariate analysis was performed to evaluate factors predictive of food impaction. Food impaction occurred in 41 of 1,360 patients (3.0%). The food impaction rates for types A, B, C, D, and E stents were 0.6%, 1.7%, 1.1%, 3.2%, and 4.0%, respectively. Multivariate analysis showed that stent length was an independent predictor of food impaction (odds ratio, 0.839; P = .012). Of the 41 patients with food impaction, 23 underwent endoscopic management, 12 underwent fluoroscopically guided management, and six did not require management because impacted food spontaneously passed through the stent. The overall food impaction rate was 3.0%, with multiple logistic regression analysis showing that shorter stent length was the only significant predictor of food impaction. Food impaction can be managed by endoscopic or fluoroscopically guided removal or placement of a second stent. Copyright © 2011 SIR. Published by Elsevier Inc. All rights reserved.
Ali, Ziad A; Maehara, Akiko; Généreux, Philippe; Shlofmitz, Richard A; Fabbiocchi, Franco; Nazif, Tamim M; Guagliumi, Giulio; Meraj, Perwaiz M; Alfonso, Fernando; Samady, Habib; Akasaka, Takashi; Carlson, Eric B; Leesar, Massoud A; Matsumura, Mitsuaki; Ozan, Melek Ozgu; Mintz, Gary S; Ben-Yehuda, Ori; Stone, Gregg W
2016-11-26
Percutaneous coronary intervention (PCI) is most commonly guided by angiography alone. Intravascular ultrasound (IVUS) guidance has been shown to reduce major adverse cardiovascular events (MACE) after PCI, principally by resulting in a larger postprocedure lumen than with angiographic guidance. Optical coherence tomography (OCT) provides higher resolution imaging than does IVUS, although findings from some studies suggest that it might lead to smaller luminal diameters after stent implantation. We sought to establish whether or not a novel OCT-based stent sizing strategy would result in a minimum stent area similar to or better than that achieved with IVUS guidance and better than that achieved with angiography guidance alone. In this randomised controlled trial, we recruited patients aged 18 years or older undergoing PCI from 29 hospitals in eight countries. Eligible patients had one or more target lesions located in a native coronary artery with a visually estimated reference vessel diameter of 2·25-3·50 mm and a length of less than 40 mm. We excluded patients with left main or ostial right coronary artery stenoses, bypass graft stenoses, chronic total occlusions, planned two-stent bifurcations, and in-stent restenosis. Participants were randomly assigned (1:1:1; with use of an interactive web-based system in block sizes of three, stratified by site) to OCT guidance, IVUS guidance, or angiography-guided stent implantation. We did OCT-guided PCI using a specific protocol to establish stent length, diameter, and expansion according to reference segment external elastic lamina measurements. All patients underwent final OCT imaging (operators in the IVUS and angiography groups were masked to the OCT images). The primary efficacy endpoint was post-PCI minimum stent area, measured by OCT at a masked independent core laboratory at completion of enrolment, in all randomly allocated participants who had primary outcome data. The primary safety endpoint was procedural MACE. We tested non-inferiority of OCT guidance to IVUS guidance (with a non-inferiority margin of 1·0 mm 2 ), superiority of OCT guidance to angiography guidance, and superiority of OCT guidance to IVUS guidance, in a hierarchical manner. This trial is registered with ClinicalTrials.gov, number NCT02471586. Between May 13, 2015, and April 5, 2016, we randomly allocated 450 patients (158 [35%] to OCT, 146 [32%] to IVUS, and 146 [32%] to angiography), with 415 final OCT acquisitions analysed for the primary endpoint (140 [34%] in the OCT group, 135 [33%] in the IVUS group, and 140 [34%] in the angiography group). The final median minimum stent area was 5·79 mm 2 (IQR 4·54-7·34) with OCT guidance, 5·89 mm 2 (4·67-7·80) with IVUS guidance, and 5·49 mm 2 (4·39-6·59) with angiography guidance. OCT guidance was non-inferior to IVUS guidance (one-sided 97·5% lower CI -0·70 mm 2 ; p=0·001), but not superior (p=0·42). OCT guidance was also not superior to angiography guidance (p=0·12). We noted procedural MACE in four (3%) of 158 patients in the OCT group, one (1%) of 146 in the IVUS group, and one (1%) of 146 in the angiography group (OCT vs IVUS p=0·37; OCT vs angiography p=0·37). OCT-guided PCI using a specific reference segment external elastic lamina-based stent optimisation strategy was safe and resulted in similar minimum stent area to that of IVUS-guided PCI. These data warrant a large-scale randomised trial to establish whether or not OCT guidance results in superior clinical outcomes to angiography guidance. St Jude Medical. Copyright © 2016 Elsevier Ltd. All rights reserved.
Biodegradable Metals for Cardiovascular Stent Application: Interests and New Opportunities
Moravej, Maryam; Mantovani, Diego
2011-01-01
During the last decade, biodegradable metallic stents have been developed and investigated as alternatives for the currently-used permanent cardiovascular stents. Degradable metallic materials could potentially replace corrosion-resistant metals currently used for stent application as it has been shown that the role of stenting is temporary and limited to a period of 6–12 months after implantation during which arterial remodeling and healing occur. Although corrosion is generally considered as a failure in metallurgy, the corrodibility of certain metals can be an advantage for their application as degradable implants. The candidate materials for such application should have mechanical properties ideally close to those of 316L stainless steel which is the gold standard material for stent application in order to provide mechanical support to diseased arteries. Non-toxicity of the metal itself and its degradation products is another requirement as the material is absorbed by blood and cells. Based on the mentioned requirements, iron-based and magnesium-based alloys have been the investigated candidates for biodegradable stents. This article reviews the recent developments in the design and evaluation of metallic materials for biodegradable stents. It also introduces the new metallurgical processes which could be applied for the production of metallic biodegradable stents and their effect on the properties of the produced metals. PMID:21845076
Impact of stent strut design in metallic stents and biodegradable scaffolds.
Foin, Nicolas; Lee, Renick D; Torii, Ryo; Guitierrez-Chico, Juan Luis; Mattesini, Alessio; Nijjer, Sukhjinder; Sen, Sayan; Petraco, Ricardo; Davies, Justin E; Di Mario, Carlo; Joner, Michael; Virmani, Renu; Wong, Philip
2014-12-20
Advances in the understanding of healing mechanisms after stent implantation have led to the recognition of stent strut thickness as an essential factor affecting re-endothelialization and overall long term vessel healing response after Percutaneous Coronary Interventions (PCI). Emergence of Drug-eluting stents (DESs) with anti-proliferative coating has contributed to reducing the incidence of restenosis and Target Lesion Revascularization (TVR), while progress and innovations in stent materials have in the meantime facilitated the design of newer platforms with more conformability and thinner struts, producing lesser injury and improving integration into the vessel wall. Recent advances in biodegradable metal and polymer materials now also allow for the design of fully biodegradable platforms, which are aimed at scaffolding the vessel only temporarily to prevent recoil and constrictive remodeling of the vessel during the initial period required, and are then progressively resorbed thereby avoiding the drawback of leaving an unnecessary implant permanently in the vessel. The aim of this article is to review recent evolution in stent material and stent strut design while understanding their impact on PCI outcomes. The article describes the different metallic alloys and biodegradable material properties and how these have impacted the evolution of stent strut thickness and ultimately outcomes in patients. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Magnetizable stent-grafts enable endothelial cell capture
NASA Astrophysics Data System (ADS)
Tefft, Brandon J.; Uthamaraj, Susheil; Harburn, J. Jonathan; Hlinomaz, Ota; Lerman, Amir; Dragomir-Daescu, Dan; Sandhu, Gurpreet S.
2017-04-01
Emerging nanotechnologies have enabled the use of magnetic forces to guide the movement of magnetically-labeled cells, drugs, and other therapeutic agents. Endothelial cells labeled with superparamagnetic iron oxide nanoparticles (SPION) have previously been captured on the surface of magnetizable 2205 duplex stainless steel stents in a porcine coronary implantation model. Recently, we have coated these stents with electrospun polyurethane nanofibers to fabricate prototype stent-grafts. Facilitated endothelialization may help improve the healing of arteries treated with stent-grafts, reduce the risk of thrombosis and restenosis, and enable small-caliber applications. When placed in a SPION-labeled endothelial cell suspension in the presence of an external magnetic field, magnetized stent-grafts successfully captured cells to the surface regions adjacent to the stent struts. Implantation within the coronary circulation of pigs (n=13) followed immediately by SPION-labeled autologous endothelial cell delivery resulted in widely patent devices with a thin, uniform neointima and no signs of thrombosis or inflammation at 7 days. Furthermore, the magnetized stent-grafts successfully captured and retained SPION-labeled endothelial cells to select regions adjacent to stent struts and between stent struts, whereas the non-magnetized control stent-grafts did not. Early results with these prototype devices are encouraging and further refinements will be necessary in order to achieve more uniform cell capture and complete endothelialization. Once optimized, this approach may lead to more rapid and complete healing of vascular stent-grafts with a concomitant improvement in long-term device performance.
Magnetizable stent-grafts enable endothelial cell capture.
Tefft, Brandon J; Uthamaraj, Susheil; Harburn, J Jonathan; Hlinomaz, Ota; Lerman, Amir; Dragomir-Daescu, Dan; Sandhu, Gurpreet S
2017-04-01
Emerging nanotechnologies have enabled the use of magnetic forces to guide the movement of magnetically-labeled cells, drugs, and other therapeutic agents. Endothelial cells labeled with superparamagnetic iron oxide nanoparticles (SPION) have previously been captured on the surface of magnetizable 2205 duplex stainless steel stents in a porcine coronary implantation model. Recently, we have coated these stents with electrospun polyurethane nanofibers to fabricate prototype stent-grafts. Facilitated endothelialization may help improve the healing of arteries treated with stent-grafts, reduce the risk of thrombosis and restenosis, and enable small-caliber applications. When placed in a SPION-labeled endothelial cell suspension in the presence of an external magnetic field, magnetized stent-grafts successfully captured cells to the surface regions adjacent to the stent struts. Implantation within the coronary circulation of pigs (n=13) followed immediately by SPION-labeled autologous endothelial cell delivery resulted in widely patent devices with a thin, uniform neointima and no signs of thrombosis or inflammation at 7 days. Furthermore, the magnetized stent-grafts successfully captured and retained SPION-labeled endothelial cells to select regions adjacent to stent struts and between stent struts, whereas the non-magnetized control stent-grafts did not. Early results with these prototype devices are encouraging and further refinements will be necessary in order to achieve more uniform cell capture and complete endothelialization. Once optimized, this approach may lead to more rapid and complete healing of vascular stent-grafts with a concomitant improvement in long-term device performance.
Quantitative optical coherence tomography analysis for late in-stent restenotic lesions.
Fu, Qiang; Suzuki, Nobuaki; Kozuma, Ken; Miyagawa, Mutsuki; Nomura, Takahiro; Kawashima, Hideyuki; Shiratori, Yoshitaka; Ishikawa, Shuichi; Kyono, Hiroyuki; Isshiki, Takaaki
2015-01-01
Coronary optical coherence tomography (OCT) has the potential to identify in-stent neoatherosclerosis, which is a possible risk factor for late acute coronary events after drug-eluting stent implantation. The purpose of this study was to investigate differences between mid-term and late in-stent restenosis after stent implantation by quantitative and semiautomated tissue property analysis using OCT. In total, 1063 OCT image frames of 16 lesions in 15 patients were analyzed. This included 346 frames of 6 lesions in late in-stent restenosis, which was defined as restenosis that was not detected at 6 to 12 months but ≥ 12 months after follow-up coronary angiography. Signal attenuation was circumferentially analyzed using a dedicated semiautomated software. Attenuation was assessed along 200 lines delineated radially for analysis of the in-stent restenotic lesions (between the lumen and stent contours). All lines were anchored by the image wire to avoid artifacts resulting from wire location. Stronger signal attenuation at the frame level (2.46 ± 0.78 versus 1.47 ± 0.32, P < 0.001) and higher maximum signal intensity at the lesion level (9.19 ± 0.19 versus 8.84 ± 0.32, P = 0.018) were observed in late in-stent restenotic lesions than in mid-term in-stent restenotic lesions. OCT demonstrated stronger signal attenuation and higher maximum signal intensity in late in-stent restenotic lesions than in mid-term in-stent restenotic lesions, indicating the possibility of neoatherosclerosis.
Intraocular Pressure and Retinal Nerve Fibre Layer Thickness Changes After Carotid Artery Stenting.
Biberoğlu, Esra; Eraslan, Muhsin; Baltacıoğlu, Feyyaz; Midi, İpek
2017-08-01
The aim of this study was to evaluate intraocular pressure (IOP) and retinal nerve fiber layer (RNFL) changes in patients with carotid artery stenosis (CAS) after carotid artery stenting. This study was conducted as a cross-sectional, non-randomised clinical case series. Fifteen male patients (mean age: 63.6±9.1) with CAS and more than 70% carotid artery narrowing were included. All of the patients were followed in the department of neurology and were operated in the interventional radiology division. Eighteen healthy male subjects (mean age: 63.7±5.3) were included in the control group. All of the healthy subjects had a detailed ophthalmological examination and subjects with any chronic eye disease were excluded from the study. All of the participants had a detailed ophthalmological examination including tonometry using Goldmann applanation tonometry and RNFL analysis using optical coherence tomography (RTVue-100 5.1). There were no ocular ischemic symptoms in any of the participants. The mean IOP value was 15.1±2.1 mmHg in the control group and 16.6±2.4 mmHg before stent implantation, 16.4±2.2 mmHg at 1 week after implantation, 16.6±2.5 mmHg at 1 month after implantation, and 16.7±2.9 mmHg at 3 months after implantation in the CAS group. Mean RNFL thickness was 105±6 µm in the control group; in the CAS group, mean RNFL thickness values were 98±27 µm before stent implantation and 103±11 µm, 101±10 µm, and 101±11 µm at 1 week, 1 month, and 3 months after stenting. There were no significant differences between the CAS group and control group regarding IOP and RNFL thickness values (p>0.05). IOP and RNFL thickness also did not show any statistically significant changes from preoperative measurements in 3 months postoperative follow-up in the CAS group (p>0.05). IOP and RNFL thickness remained unchanged after carotid stent implantation in carotid artery stenosis patients with no signs of ocular ischemic syndrome.
Intraocular Pressure and Retinal Nerve Fibre Layer Thickness Changes After Carotid Artery Stenting
Biberoğlu, Esra; Eraslan, Muhsin; Baltacıoğlu, Feyyaz; Midi, İpek
2017-01-01
Objectives: The aim of this study was to evaluate intraocular pressure (IOP) and retinal nerve fiber layer (RNFL) changes in patients with carotid artery stenosis (CAS) after carotid artery stenting. Materials and Methods: This study was conducted as a cross-sectional, non-randomised clinical case series. Fifteen male patients (mean age: 63.6±9.1) with CAS and more than 70% carotid artery narrowing were included. All of the patients were followed in the department of neurology and were operated in the interventional radiology division. Eighteen healthy male subjects (mean age: 63.7±5.3) were included in the control group. All of the healthy subjects had a detailed ophthalmological examination and subjects with any chronic eye disease were excluded from the study. All of the participants had a detailed ophthalmological examination including tonometry using Goldmann applanation tonometry and RNFL analysis using optical coherence tomography (RTVue-100 5.1). Results: There were no ocular ischemic symptoms in any of the participants. The mean IOP value was 15.1±2.1 mmHg in the control group and 16.6±2.4 mmHg before stent implantation, 16.4±2.2 mmHg at 1 week after implantation, 16.6±2.5 mmHg at 1 month after implantation, and 16.7±2.9 mmHg at 3 months after implantation in the CAS group. Mean RNFL thickness was 105±6 µm in the control group; in the CAS group, mean RNFL thickness values were 98±27 µm before stent implantation and 103±11 µm, 101±10 µm, and 101±11 µm at 1 week, 1 month, and 3 months after stenting. There were no significant differences between the CAS group and control group regarding IOP and RNFL thickness values (p>0.05). IOP and RNFL thickness also did not show any statistically significant changes from preoperative measurements in 3 months postoperative follow-up in the CAS group (p>0.05). Conclusion: IOP and RNFL thickness remained unchanged after carotid stent implantation in carotid artery stenosis patients with no signs of ocular ischemic syndrome. PMID:28845322
Kralev, Stefan; Haag, Benjamin; Spannenberger, Jens; Lang, Siegfried; Brockmann, Marc A.; Bartling, Soenke; Marx, Alexander; Haase, Karl-Konstantin; Borggrefe, Martin; Süselbeck, Tim
2011-01-01
Background Treatment of coronary bifurcation lesions remains challenging, beyond the introduction of drug eluting stents. Dedicated stent systems are available to improve the technical approach to the treatment of these lesions. However dedicated stent systems have so far not reduced the incidence of stent restenosis. The aim of this study was to assess the expansion of the Multi-Link (ML) Frontier™ stent in human and porcine coronary arteries to provide the cardiologist with useful in-vitro information for stent implantation and selection. Methodology/Principal Findings Nine ML Frontier™ stents were implanted in seven human autopsy heart samples with known coronary artery disease and five ML Frontier™ stents were implanted in five porcine hearts. Proximal, distal and side branch diameters (PD, DD, SBD, respectively), corresponding opening areas (PA, DA, SBA) and the mean stent length (L) were assessed by micro-computed tomography (micro-CT). PD and PA were significantly smaller in human autopsy heart samples than in porcine heart samples (3.54±0.47 mm vs. 4.04±0.22 mm, p = 0.048; 10.00±2.42 mm2 vs. 12.84±1.38 mm2, p = 0.034, respectively) and than those given by the manufacturer (3.54±0.47 mm vs. 4.03 mm, p = 0.014). L was smaller in human autopsy heart samples than in porcine heart samples, although data did not reach significance (16.66±1.30 mm vs. 17.30±0.51 mm, p = 0.32), and significantly smaller than that given by the manufacturer (16.66±1.30 mm vs. 18 mm, p = 0.015). Conclusions/Significance Micro-CT is a feasible tool for exact surveying of dedicated stent systems and could make a contribution to the development of these devices. The proximal diameter and proximal area of the stent system were considerably smaller in human autopsy heart samples than in porcine heart samples and than those given by the manufacturer. Special consideration should be given to the stent deployment procedure (and to the follow-up) of dedicated stent systems, considering final intravascular ultrasound or optical coherence tomography to visualize (and if necessary optimize) stent expansion. PMID:21814552
Complex coronary lesions and rotational atherectomy: one hospital’s experience*
Jiang, Jun; Sun, Yong; Xiang, Mei-xiang; Dong, Liang; Liu, Xian-bao; Hu, Xin-yang; Feng, Yan; Wang, Jian-an
2012-01-01
Objective: To evaluate the safety and effectiveness of rotational atherectomy followed by drug eluting stent (DES) implantation in patients with complex coronary lesions. Methods: From August 2006 to August 2012, 253 consecutive patients with 289 lesions and who underwent rotational atherectomy in our center were enrolled in this study. Results: The overall procedure success rate was 98% with the cost of two (0.8%) coronary perforations, three (1.2%) dissections, five (2.0%) slow flows or no flows, three (1.2%) peri-procedure myocardial infarctions, and two (0.8%) in hospital deaths. During follow-up (mean three years), one (0.4%) patient died, two (0.8%) patients had acute myocardial infarction, 14 (5.5%) had restenosis, and target lesion revascularization occurred in eight patients (3.2%). Conclusions: Rotational atherectomy followed by DES implantation is a safe and effective technique for patients with complex coronary lesions, especially calcified and non-dilatable lesions. PMID:22843185
When Not to Go SOLO? Contraindications Based on Implant Experience.
Wollersheim, Laurens W; Li, Wilson W; Kaya, Abdullah; van Boven, Wim J; van der Meulen, Jan; de Mol, Bas A
2016-11-01
Because of the design and specific implantation technique of the stentless Freedom SOLO bioprosthesis, patient selection is crucial. The aim of the study was to discuss the contraindications to this prosthesis based on the authors' implant experience. Between April 2005 and February 2015, one surgeon at the authors' center performed 292 aortic valve replacements using a bioprosthesis, with the initial intention of implanting a SOLO valve in every patient. A search was conducted for all of these patients and data collected on whether a SOLO valve was used, or not. A SOLO valve was implanted in 238 patients (82%), and a stented bioprosthesis in 54 (18%). The predominant reasons not to implant a SOLO valve were asymmetric commissures (26%) and a large aortic annulus (24%). Only one patient had structural valve deterioration, and none of the patients had to undergo reoperation because of aortic valve insufficiency or paravalvular leakage. Asymmetric commissures, large aortic annulus (>27 mm), calcified aortic sinuses, dilated sinotubular junction, aberrant location of coronary ostia and whenever the stent of a stented bioprosthesis is useful, were contraindications to implant a SOLO valve. When these contraindications were taken into account, a very good durability could be achieved with the SOLO valve during mid-term follow up.
Natural stent in the management of post-intubation tracheal stenosis.
Park, Hye Yun; Kim, Hojoong; Koh, Won-Jung; Suh, Gee Young; Chung, Man Pyo; Kwon, O Jung
2009-05-01
The treatment choice for post-intubation tracheal stenosis (PITS) in patients for whom surgery is not initially feasible is bronchoscopic silicone stenting. A new silicone stent, called the Natural stent (N stent), was investigated for its clinical efficacy and safety in patients with PITS. A retrospective review was conducted of 32 patients with PITS who underwent N stenting between November 2001 and December 2006 and were followed for at least 12 months. Airway dilatation with combined modalities such as Nd:YAG laser, ballooning or bougienage was followed by N stent insertion. After intervention, all patients had symptomatic and spirometric improvement without immediate complications. Removal of the stent without re-stenosis was successful in 38% of the patients at a median time of 7 months after insertion. The stent could not be removed or needed reinsertion in 31% of patients, and 16% of patients underwent surgery after initial stabilization by stenting. Late complications were stent migration (34%), mucostasis (31%), granulation tissue formation (38%) and re-stenosis (40%). All patients tolerated the management of complications during a median follow up of 22 months. Bronchoscopic N stenting is an effective treatment for patients with PITS in whom surgery is not feasible on initial presentation. Further stent development is necessary to reduce the late complication rate.
Abdominal aortic aneurysm neck remodeling after Anaconda stent graft implantation.
Vukovic, Elisabeth; Czerny, Martin; Beyersdorf, Friedhelm; Wolkewitz, Martin; Berezowski, Mikolaj; Siepe, Matthias; Blanke, Philipp; Rylski, Bartosz
2018-05-24
The aim of this study was to define how the proximal landing zone changes geometrically after endovascular abdominal aortic aneurysm repair (EVAR) with the Anaconda (Vascutek, Inchinnan, United Kingdom) stent graft. Among 230 patients who underwent Anaconda stent graft implantation between 2005 and 2014, we included 126 with adequate computed tomography (CT) image quality and follow-up. CT analysis entailed the geometric changes in the main body, proximal rings, and proximal landing zone. The median CT follow-up was 2.0 years (345.8 patients-years). The proximal portion of the main body ring system flattened within the first year after EVAR, resulting in an up to 30° increase in the upper ring's angle in 40% patients and up to 40° increase in 24% patients. One year after EVAR, the upper ring angle increase slowed down. Aortic diameter measured at the level of the upper and lower ring expanded by 2 to 4 mm within 1 year, but remained unchanged afterward. The main body migrated continuously down toward the aortic bifurcation, attaining an average 6-mm increase in the distance between the superior mesenteric artery and main body within 4 years. Freedom from endoleak type IA was 95 ± 2% and 93 ± 3% after 1 and 4 years, respectively. The Anaconda main body ring system in its proximal portion flattens within the first year after EVAR, leading to an increase of 2 to 4 mm in the proximal landing zone's aortic diameter. The main body migrates slowly but continuously down toward the aortic bifurcation. Copyright © 2018 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
Ranjan, Alok; Patel, Tejas M; Shah, Sanjay C; Malhotra, Hemant; Patel, Rajni; Vayada, Nishith; Pothiwala, Rasesh; Fonseca, Keith; Tanwar, Narendra S
2005-01-01
Coronary angioplasty and stent implantation is effective as primary intervention in acute myocardial infarction. Because of fewer puncture site complications and improved patient comfort, transradial access has been increasingly used as an alternative to transfemoral access for percutaneous coronary interventions. We studied 103 patients (94 men, 9 women: mean age 52.5 +/- 11.96 years) with a diagnosis of acute myocardial infarction (<12 hours after onset), who underwent primary percutaneous coronary intervention. Transradial access was used in all patients with a normal Allen's test and transfemoral access was used additionally only if intra-aortic balloon counterpulsation was required. Follow-up duration was 6 months. Transradial access was successfully achieved in all patients. Radial artery cannulation took <2 min in more than 85% patients. During percutaneous coronary intervention, cannulation to balloon inflation times and total procedure times were 11.3 +/- 5.2 min and 19.9 +/- 10.8 min, respectively. Stents were implanted in 99 (96.1%) patients andplain balloon angioplastywas performed in 3.9%. The primary success rate was 98.1%, with no major bleeding complications. Total length of hospitalization averaged 2.4 +/- 0.8 days. In-hospital major adverse clinical events rate was 5.9%. Six-month clinical follow-up was achieved for 84 (86.6%) patients. Six (7.1%) patients died during follow-up. Follow-up coronary angiography was performed in 22 (26.2%) patients. After 6 months, 7 patients required revascularizationof the target lesion. The rate of survival without myocardial infarction, bypass surgery or repeat coronary angioplasty was 88.5% at 6 months. Transradial access may represent a safe and feasible technique for performing primary percutaneous coronary intervention with good acute results and without major bleeding complications.
Kan, Jing; Ge, Zhen; Zhang, Jun-Jie; Liu, Zhi-Zhong; Tian, Nai-Liang; Ye, Fei; Li, Sui-Ji; Qian, Xue-Song; Yang, Song; Chen, Meng-Xuan; Rab, Tanveer; Chen, Shao-Liang
2016-06-13
The present study aimed to analyze the incidence of SF and its correlation with clinical events after DES implantation and the outcome of re-intervention for symptomatic in-stent restenosis (ISR) induced by stent fracture (SF). SF is associated with a high rate of clinical events after the implantation of drug-eluting stents (DES). However, the chronological rate of SF and the effect of SF on clinical outcomes from a large patient population remain underreported. A total of 6,555 patients with 16482 DES in 10751 diseased vessels and surveillance angiography between November 2003 and January 2014 were prospectively studied. The primary endpoints included the incidence of SF, in-stent restenosis (ISR), target lesion revascularization (TLR), and definite stent thrombosis (ST) at the end of follow-up before and after propensity score matching. Clinical outcomes after TLR were also followed up. The SF rate was detected in 803 (12.3%) patients, 3,630 (22.0%) stents, and 1,852 (17.2%) diseased vessels. SF increased over time. SF was associated with higher unadjusted rates of ISR (42.1%), TLR (24.8%, n = 379), and definite ST (4.6%) compared with stents without fracture (10.7%, 6.6%, and 1.03%, all p < 0.001), and the differences remained significant after propensity score matching (all p < 0.05). There was no significant difference in any-cause or cardiac mortality between patients with and without SF. After 1,523 days of follow-up since the first surveillance angiography, repeat ISR was detected in 90 of 379 (23.8%) stents after reintervention, and 6 (7.5%) stents required repeat TLR. SF is more frequently observed after DES implantation. TLR was required in almost one-fourth of fractured stents. Increased events in the SF group did not translate into a difference in mortality compared with the non-SF group. Reintervention was associated with acceptable clinical results. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Efficacy of therapy for hepatocellular carcinoma with portal vein tumor thrombus
Chuan-Xing, Li; Xu, He; Bao-Shan, Hu; Yong, Li; Pei-Jian, Shao; Xian-Yi, Yu; Xiao-Ning, Luo
2011-01-01
The purpose of this study is to analyze the safety and clinical efficacy of transcatheter arterial chemoembolization (TACE) combined with portal vein stent and 125I implantation for the treatment of portal vein tumor thrombus (PVTT) in hepatocellular carcinoma. Fifty-six patients from our department diagnosed with advanced hepatocellular carcinoma with PVTT between January 2008 and December 30, 2010 were divided into two groups. Patients in Group A were treated with TACE and portal vein stent; patients in Group B were treated with TACE, portal vein stent and 125I implantation. The success rate of TACE with portal vein stent and 125I implantation was 100%, with no severe surgery-related complications. After an 8 mo follow-up, the total clinical benefit rates were 56.7 and 88.5% for Groups A and B, respectively (p < 0.05). The median survival times (mOS) for the two groups were 5.7 and 8.9 mo, respectively (p < 0.05). The median time of progression (mTTP) of the two groups were 5.3 and 7.9 mo, respectively (p < 0.05). The 2, 6, 8, 12 and 18 mo patency rates in Group A were 100, 93.3, 83.3, 53.3 and 36.6%. Those in Group B were 100, 100, 92.3, 84.6 and 80.7%. The 2, 6 and 8 mo patency rates showed no statistical differences (p > 0.05), but the 12 and 18 mo rates did (p < 0.05). Our results suggest that TACE combined with portal vein stent and 125I implantation are both safe and effective, and 125I implantation can further postpone the restenosis of the portal vein effectively. PMID:22037354
Bioresorbable Electronic Stent Integrated with Therapeutic Nanoparticles for Endovascular Diseases.
Son, Donghee; Lee, Jongha; Lee, Dong Jun; Ghaffari, Roozbeh; Yun, Sumin; Kim, Seok Joo; Lee, Ji Eun; Cho, Hye Rim; Yoon, Soonho; Yang, Shixuan; Lee, Seunghyun; Qiao, Shutao; Ling, Daishun; Shin, Sanghun; Song, Jun-Kyul; Kim, Jaemin; Kim, Taeho; Lee, Hakyong; Kim, Jonghoon; Soh, Min; Lee, Nohyun; Hwang, Cheol Seong; Nam, Sangwook; Lu, Nanshu; Hyeon, Taeghwan; Choi, Seung Hong; Kim, Dae-Hyeong
2015-06-23
Implantable endovascular devices such as bare metal, drug eluting, and bioresorbable stents have transformed interventional care by providing continuous structural and mechanical support to many peripheral, neural, and coronary arteries affected by blockage. Although effective in achieving immediate restoration of blood flow, the long-term re-endothelialization and inflammation induced by mechanical stents are difficult to diagnose or treat. Here we present nanomaterial designs and integration strategies for the bioresorbable electronic stent with drug-infused functionalized nanoparticles to enable flow sensing, temperature monitoring, data storage, wireless power/data transmission, inflammation suppression, localized drug delivery, and hyperthermia therapy. In vivo and ex vivo animal experiments as well as in vitro cell studies demonstrate the previously unrecognized potential for bioresorbable electronic implants coupled with bioinert therapeutic nanoparticles in the endovascular system.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gutzeit, A., E-mail: andreas.gutzeit@ksw.ch; Zollikofer, Ch. L., E-mail: Christoph.Zollikofer@ksb.ch; Dettling-Pizzolato, M., E-mail: Mira.Dettling@ksw.ch
Venous stenting has been shown to effectively treat iliofemoral venous obstruction with good short- and mid-term results. The aim of this study was to investigate long-term clinical outcome and stent patency. Twenty patients were treated with venous stenting for benign disease at our institution between 1987 and 2005. Fifteen of 20 patients (15 female, mean age at time of stent implantation 38 years [range 18-66]) returned for a clinical visit, a plain X-ray of the stent, and a Duplex ultrasound. Four patients were lost to follow-up, and one patient died 277 months after stent placement although a good clinical resultmore » was documented 267 months after stent placement. Mean follow-up after stent placement was 167.8 months (13.9 years) (range 71 (6 years) to 267 months [22 years]). No patient needed an additional venous intervention after stent implantation. No significant difference between the circumference of the thigh on the stented side (mean 55.1 cm [range 47.0-70.0]) compared with the contralateral thigh (mean 54.9 cm [range 47.0-70.0]) (p = 0.684) was seen. There was a nonsignificant trend toward higher flow velocities within the stent (mean 30.8 cm/s [range 10.0-48.0]) and the corresponding vein segment on the contralateral side (mean 25.2 cm/s [range 12.0-47.0]) (p = 0.065). Stent integrity was confirmed in 14 of 15 cases. Only one stent showed a fracture, as documented on x-ray, without any impairment of flow. Venous stenting using Wallstents showed excellent long-term clinical outcome and primary patency rate.« less
Lee, Sahmin; Yoon, Chang-Hwan; Oh, Il-Young; Suh, Jung-Won; Cho, Young-Seok; Cho, Goo-Yeong; Chae, In-Ho; Choi, Dong-Ju; Youn, Tae-Jin
2015-01-01
The angiographic features of restenosis contain prognostic information. However, restenosis patterns of the new generation drug-eluting stents (DES), everolimus-(EES) and resolute zotarolimus-eluting stent (ZES) have not been described.A total of 210 consecutive patients with DES restenosis were enrolled from 2003 to 2012. We analyzed 217 restenotic lesions after DES implantation, and compared the morphologic characteristics of the 2nd generation DES restenosis to those of restenosis with 2 first generation DES, sirolimus-(SES) and paclitaxel-eluting stent (PES).Baseline characteristics were comparable between the different stent groups. The incidence of focal restenosis was significantly lower for PES than the other stents (49.5% versus 87.0%, 76.2%, and 82.1% for PES versus SES, EES, and ZES, respectively, P < 0.001). When considering the pattern of restenosis solely within the stent margins, a further clear distinction between PES and other stents was observed (40.0% versus 92.9%, 88.9%, and 81.2% in PES versus SES, EES, and ZES, respectively, P < 0.001). There were no significant differences in restenosis patterns among SES, EES, and ZES. In multivariate analysis, PES implantation, hypertension, and age were associated with non-focal type of restenosis after DES implantation. After the introduction of EES and ZES into routine clinical practice in 2008, focal restenosis significantly increased from 63.9% to 76.7% and diffuse restenosis significantly decreased from 26.4% to 11.0% (P = 0.045).Focal restenosis was the most common pattern of restenosis in the new generation DES and the incidence of diffuse restenosis significantly decreased with the introduction of the 2nd generation DES.
Potential mechanisms of in-stent occlusion in the femoropopliteal artery: an angioscopic assessment.
Ishihara, Takayuki; Iida, Osamu; Okamoto, Shin; Fujita, Masashi; Masuda, Masaharu; Nanto, Kiyonori; Shiraki, Tatsuya; Kanda, Takashi; Tsujimura, Takuya; Okuno, Shota; Yanaka, Koji; Uematsu, Masaaki
2017-10-01
Although stent implantation has become widespread for the treatment of patients with peripheral artery disease with femoropopliteal (FP) lesions, in-stent restenosis, especially in-stent occlusion (ISO), remains as a major concern for refractory recurrence. Furthermore, the mechanisms of ISO in FP lesions have not been well elucidated. We performed angioscopy for 6 lesions (bare-metal stent: 3, drug-eluting stent: 3) from 5 patients (mean age 74 ± 10 years, male 40 %) with ISO in the FP artery immediately after wire-passing or thrombus aspiration. The presence of thrombus as well as the presence and location of organic stenosis were evaluated. Median duration from stent implantation to angioscopic evaluation was 1099.5 (514.5-2272.5) days, while the duration from recurrence of symptoms to angioscopic evaluation was 45 (5.75-60) days. Mixed thrombi were observed in all stents. Organic stenosis was detected at the proximal edge of the stents in 5 lesions. Organic stenosis was observed at the overlapping segment of the stent in one lesion. The distal edge of the stents could be evaluated in 3 lesions, and all of them showed organic stenosis at the site. Mixed thrombi and organic stenosis were observed in all stents. Partial development of organic stenosis in a stent followed by thrombus formation may be the potential mechanism of the development of ISO in the FP artery though the sample size of this study was small and it had no serial angioscopic data so that we should consider it as preliminary one at best.
Experimental Study of Poly-l-Lactic Acid Biodegradable Stents in Normal Canine Bile Ducts
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yamamoto, Kiyosei, E-mail: yamakiyo@zg7.so-net.ne.jp; Yoshioka, Tetsuya; Furuichi, Kinya
Purpose: This study was designed to clarify the advantages of biodegradable stents in terms of mucosal reaction and biodegradation after placement. We designed a biodegradable stent and assessed stent degradation and changes in the normal bile ducts of dogs. Methods: The biodegradable stent is a balloon-expandable Z stent consisting of poly-l-lactic acid (PLLA) with a diameter of 6 mm and a length of 15 mm. We assessed four groups of three beagle dogs each at 1, 3, 6, and 9 months of follow-up. After evaluating stent migration by radiography and stent and bile duct patency by cholangiography, the dogs weremore » sacrificed to remove the bile duct together with the stent. The bile duct lumen was examined macroscopically and histologically, and the stent degradation was examined macroscopically and by scanning electron microscopy (SEM). Results: Bile duct obstruction was absent and none of the stents migrated. Macroscopic evaluation showed moderate endothelial proliferation in the bile ducts at the implant sites at 3 and 6 months and a slight change at 9 months. Slight mononuclear cell infiltration was histologically identified at all time points and epithelial hyperplasia that was moderate at 3 months was reduced to slight at 6 and 9 months. Stent degradation was macroscopically evident in all animals at 9 months and was proven by SEM in two dogs at 6 months and in all of them at 9 months. Conclusions: Our results suggest that PLLA bioabsorbable stents seems to be useful for implantation in the biliary system with further investigation.« less
Baril, Donald T; Rhee, Robert Y; Kim, Justine; Makaroun, Michel S; Chaer, Rabih A; Marone, Luke K
2009-01-01
Endovascular intervention is considered first-line therapy for most superficial femoral artery (SFA) occlusive disease. Duplex ultrasound (DU) criteria for SFA in-stent stenosis and correlation with angiographic data remain poorly defined. This study evaluated SFA-specific DU criteria for the assessment of SFA in-stent stenosis. From May 2003 to May 2008, 330 limbs underwent SFA angioplasty and stenting and were monitored by serial DU imaging. Suspected stenotic lesions underwent angiography and intervention when appropriate. Data pairs of DU and angiographically estimated stenosis
Mohammed, Noor; Pinder, Matthew; Harris, Keith; Everett, Simon M
2016-07-01
Conventional endoscopic duct clearance may not be possible in up to 10%-15% of common bile duct stones (CBDS). Sphincterotomy and biliary drainage by endoprosthesis have for many years been the mainstay of management in irretrievable stones. Recent years have seen the advent of sphincteroplasty or cholangioscopically-guided electrohydraulic lithotripsy (EHL) permitting duct clearance in majority of cases. However, when bile duct clearance is not possible, options include long-term stenting followed by elective stent exchange (ESE) 6-12 monthly or permanent stent insertion (PSI) in selected cases, but it is not clear which management strategy among ESE and PSI is preferable. A retrospective review of all patients in Leeds Teaching Hospitals NHS Trust who underwent plastic stent insertion for biliary access for difficult CBDS from January 2006 to December 2011 was undertaken. Adult patients with irretrievable CBDS who had plastic stent insertions throughout the follow-up period were included. Patients who underwent PSI and ESE annually were retrospectively reviewed to determine the long-term outcomes. A detailed systematic review was also performed, examining the outcomes of CBDS managed with stents. During the study period, 674 patients underwent 1769 biliary-stent-related procedures; of which, 246 patients met our inclusion criteria. 201 patients had subsequent duct clearance. 45 patients were, therefore, included in the final analysis, 28 of whom underwent annual ESEs and 17 PSIs. Patients in the PSI group had higher American Society of Anesthesiologists (ASA) scores compared with the ESE group. In the PSI group, 9/17 patients presented acutely with blocked stents, 5 of whom presented within 12 months. 2/9 patients were severely ill and died within a fortnight following the repeat endoscopic retrograde cholangiopancreatography (ERCP). In the ESE group, 4/28 patients had duct clearance in subsequent ERCPs, 1/28 patient presented with a blocked stent, and no biliary-related deaths were observed. The mean numbers of ERCPs performed were 0.52 and 1.95 in the PSI and ESE groups, respectively. Over 50% of patients treated with long-term stenting re-presented acutely with stent blockage, though many of these were before 12 months, meaning planned stent exchange would not have affected the outcome. Duct clearance using all possible modalities is the preferred option, but where not possible, management with biliary stenting either with elective exchange or permanent stenting remains a possibility for carefully selected patients, though maybe best suited to those with limited life expectancy.
Kim, Jin Hyoung; Gwon, Dong Il; Ko, Gi-Young; Sung, Kyu-Bo; Lee, Sung Koo; Yoon, Hyun-Ki; Shin, Ji Hoon; Song, Ho-Young
2011-06-01
To compare retrospectively percutaneous transhepatic primary placement of a retrievable self-expanding metallic stent with percutaneous balloon dilation for the treatment of benign biliary strictures. From 2005-2009, 66 patients with benign biliary strictures in whom an endoscopic approach failed or in whom such an approach was inaccessible were evaluated. Of 66 patients, 31 underwent balloon dilation, and 35 underwent temporary metallic stent placement. The etiologies of the benign strictures were anastomotic stricture after surgery (n = 54), stricture secondary to intraoperative injury (n = 9), inflammatory stricture (n = 2), and stricture secondary to trauma (n = 1). The primary patency rates were significantly better in the stent group (87% at 3 years) than in the balloon group (44% at 3 years; P = .022). The indwelling period of percutaneous transhepatic biliary drainage (PTBD) catheters after the initial procedure was able to be significantly reduced in the stent group (median 2.5 months) compared with the balloon group (median 4.5 months; P = .001). Significant bleeding (associated with PTBD) occurred in one patient in the balloon group. In the stent group, stent migration occurred in two patients, and one patient underwent surgery for stent removal after failure of removal under fluoroscopic guidance. Percutaneous primary placement of a retrievable self-expanding metallic stent showed superior intermediate-term results compared with percutaneous balloon dilation for the treatment of benign biliary strictures. In addition, the indwelling period of PTBD catheters can be significantly reduced using temporary stent placement. Copyright © 2011 SIR. Published by Elsevier Inc. All rights reserved.
Risk Factors for Hepatic Morbidity Following Nonoperative Management: Multicenter Study
2006-05-01
with a primary bile duct leak at ERCP. The last patient underwent laparotomy for a biliary -venous fistula that failed to resolve by ERCP and stenting ...the patient with a biliary -venous fistula underwent laparotomy and ERCP with stenting to manage this complication and then later, IR drainage of a...peritonitis,17 and stenting rather than sphincter- otomy is felt to expedite healing of biliary leaks.18 Al- though we had relatively few bile duct
Zhu, Qiang; Zang, Qi; Jiang, Zhong-min; Wang, Wei; Cao, Ming
2013-06-01
To assess the feasibility, safety and efficacy of the use of a fully covered self-expandable stent for the treatment of airway fistula. From August 2005 to November 2011, 9 patients underwent treatment by the introduction of a tracheo-bronchial or bronchial fully covered self-expandable metallic stent. There were 7 males and 2 females, aged from 28-65 years with a mean of 46 years. In this group, 7 cases were diagnosed as bronchopleural fistula, 1 case as tracheopleural fistula, 1 case as broncho-esophageal fistula, 8 cases with thoracic empyema. The fistula orifices were from 3.5-25.0 mm in diameter with a mean 8.4 mm. All patients received topical anesthesia, and L-shaped stent was placed in 6 patients and I-shaped stent in 3 patients under fluoroscopic guidance. After the stent placement, the patients with empyema were treated with continual irrigation of the empyema cavity. Stent placement in the tracheo-bronchial tree was technically successful in all patients, without procedure-related complications. The operating time was from 5-16 minutes, mean time (10 ± 4) minutes. Except for 1 patient, immediate closure of the airway fistula was achieved in the other patients after the procedure, as shown by the immediate cessation of bubbling in the chest drain system or the contrast examination. In this study, 1 patient coughed the inserted stent out due to irritable cough on the 5th day and had to receive repositioning of a new stent. Among the patients who were with empyema, 1 patient died of septicemia on the 8th day and 1 patient died of brain metastases from lung cancer 6 months after the stent insertion with empyema not cured, the other 6 patients' empyema healed from 2-5 months, mean time 3.7 months. Seven patients were followed from 3 to 36 months with a median of 13.5 months. During follow-up, 1 stent was removed from a patient 8 months after the stent implantation without empyema recurred. The remaining patient presented good tolerability to the existence of stent. The stents remained stable, no migration occurred, no empyema recurred, and the patient with broncho-esophageal fistula fed and drunk well. The use of fully covered self-expandable stents proved to be a safe, effective and fast minimally invasive method to treat airway fistula, especially for patients with a higher surgical risk or other failed treatments.
A comparative evaluation of early stent occlusion among biliary conventional versus wing stents.
Khashab, Mouen A; Hutfless, Susan; Kim, Katherine; Lennon, Anne Marie; Canto, Marcia I; Jagannath, Sanjay B; Okolo, Patrick I; Shin, Eun Ji; Singh, Vikesh K
2012-06-01
Conventional plastic stents with a lumen typically have limited patency. The lumenless wing stent was engineered to overcome this problem. The objective of this study was to compare the incidence of early stent occlusion (symptomatic occlusion/cholangitis necessitating re-insertion within 90 days) for wing stents and conventional plastic stents. Patients with biliary pathology treated with plastic biliary stenting during the period 2003-2009 comprised the study cohort. Patients who had at least one biliary wing stent placed comprised the wing stent group, whereas patients who underwent only conventional stent plastic placement comprised the conventional stent group. Patients were stratified by indication: benign biliary strictures (group 1), malignant biliary strictures (group 2), or benign biliary non-stricture pathology (group 3). The association of stent type with the occurrence of primary outcome by indication was analyzed by use of multivariable logistic regression. Three-hundred and forty-six patients underwent 612 ERCP procedures with placement of plastic biliary stent(s). On multivariate analysis, early stent occlusion did not differ between the wing and conventional groups in groups 1, 2, and 3. Among patients who achieved primary outcome in group 2, significantly fewer patients in the wing group had cholangitis (6.7% vs. 39.1%, P = 0.03). Among patients who achieved primary outcome in group 3, significantly fewer patients in the wing group had cholangitis (10% vs. 50%, P = 0.03). Early stent occlusion was similar for wing stents and conventional plastic stents. Wing stents, however, were associated with a lower incidence of cholangitis in patients with malignant biliary obstruction and benign non-stricturing biliary pathology.
Bioabsorbable Stent Quo Vadis: A Case for Nano-Theranostics
Gundogan, Buket; Tan, Aaron; Farhatnia, Yasmin; Alavijeh, Mohammad S.; Cui, Zhanfeng; Seifalian, Alexander M.
2014-01-01
Percutaneous coronary intervention (PCI) is one of the most commonly performed invasive medical procedures in medicine today. Since the first coronary balloon angioplasty in 1977, interventional cardiology has seen a wide array of developments in PCI. Bare metal stents (BMS) were soon superseded by the revolutionary drug-eluting stents (DES), which aimed to address the issue of restenosis found with BMS. However, evidence began to mount against DES, with late-stent thrombosis (ST) rates being higher than that of BMS. The bioabsorbable stent may be a promising alternative, providing vessel patency and support for the necessary time required and thereafter degrade into safe non-toxic compounds which are reabsorbed by the body. This temporary presence provides no triggers for ST, which is brought about by non-endothelialized stent struts and drug polymers remaining in vivo for extended periods of time. Likewise, nano-theranostics incorporated into a bioabsorbable stent of the future may provide an incredibly valuable single platform offering both therapeutic and diagnostic capabilities. Such a stent may allow delivery of therapeutic particles to specific sites thus keeping potential toxicity to a minimum, improved ease of tracking delivery in vivo by embedding imaging agents, controlled rate of therapy release and protection of the implanted therapy. Indeed, nanocarriers may allow an increased therapeutic index as well as offer novel post-stent implantation imaging and diagnostic methods for atherosclerosis, restenosis and thrombosis. It is envisioned that a nano-theranostic stent may well form the cornerstone of future stent designs in clinical practice. PMID:24672583
Løvdal, Alexandra Liv Vest; Calve, Sarah; Yang, Shuo; Van Alstine, William; Binkert, Christoph A; Klausen, Kasper
2017-01-01
This study was designed to evaluate performance and tissue response to a self-expandable bioabsorbable vein stent-base cut from a tube with enhanced stiffness and strength in vitro and in vivo. A diamond-shaped stent-base was cut from a sequential biaxially strained poly(L-lactide) (PLLA) tube for optimized performance. The performance of the stent-base was evaluated in a finite element analysis model, and validation was attempted in vitro through a cyclic flat-plate compression and radial force measurement. The performance of the stent-base was tested in vivo using 3 sheep with 2 implants each for 2 and 3½ weeks, respectively. In vitro the stent-base showed an elliptical deformation but no fractures. In vivo the stent-base showed adequate radial force and no migration. All implanted stent-bases showed multiple fractures not only at the predicted stress zones but at all connecting points. Fragments of the caudal stent-base stayed in the vein wall indicating sufficient tissue coverage to avoid embolization of the fractured stent pieces, whereas fragments from the cranial device remaining were few. Neointima formation was confirmed histologically at 2 and 3½ weeks. A bioabsorbable self-expandable stent-base made from PLLA for large veins seems feasible, but over time, the PLLA used in this study appears too stiff and lacks the sufficient flexibility to move with the vena cava, causing multiple fractures.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Løvdal, Alexandra Liv Vest, E-mail: alvlo@nanotech.dtu.dk; Calve, Sarah; Yang, Shuo
PurposeThis study was designed to evaluate performance and tissue response to a self-expandable bioabsorbable vein stent-base cut from a tube with enhanced stiffness and strength in vitro and in vivo.MethodsA diamond-shaped stent-base was cut from a sequential biaxially strained poly(l-lactide) (PLLA) tube for optimized performance. The performance of the stent-base was evaluated in a finite element analysis model, and validation was attempted in vitro through a cyclic flat-plate compression and radial force measurement. The performance of the stent-base was tested in vivo using 3 sheep with 2 implants each for 2 and 3½ weeks, respectively.ResultsIn vitro the stent-base showed anmore » elliptical deformation but no fractures. In vivo the stent-base showed adequate radial force and no migration. All implanted stent-bases showed multiple fractures not only at the predicted stress zones but at all connecting points. Fragments of the caudal stent-base stayed in the vein wall indicating sufficient tissue coverage to avoid embolization of the fractured stent pieces, whereas fragments from the cranial device remaining were few. Neointima formation was confirmed histologically at 2 and 3½ weeks.ConclusionA bioabsorbable self-expandable stent-base made from PLLA for large veins seems feasible, but over time, the PLLA used in this study appears too stiff and lacks the sufficient flexibility to move with the vena cava, causing multiple fractures.« less
Spira, Daniel; Wiskirchen, Jakub; Lauer, Ulrich; Ketelsen, Dominik; Nikolaou, Konstantin; Wiesinger, Benjamin
2016-07-01
The transjugular intrahepatic portosystemic stent-shunt (TIPSS) builds a shortcut between the portal vein and a liver vein, and represents a sophisticated alternative to open surgery in the management of portal hypertension or its complications. To describe clinical experiences with a low-profile nitinol stent system in TIPSS creation, and to assess primary and long-term success. Twenty-six patients (5 females, 21 males; mean age 54.6 years) were treated using a low-profile 6F self-expanding sinus-SuperFlex-Visual stent system. The indication for TIPSS creation was refractory bleeding in 9 of the 26 patients, refractory ascites in 18 patients, and acute thrombosis of the portal vein confluence in one patient. Portosystemic pressure gradients before and after TIPSS, periprocedural and long-term complications, and the time to orthotopic liver transplantation (OLT) or death were recorded. The portosystemic pressure gradient was significantly reduced, from 20.9 ± 6.3 mmHg before to 8.2 ± 2.3 mmHg after TIPSS creation (P < 0.001). Procedure-related complications included acute tract occlusion (n = 2), liver hematoma (n = 1), hepatic encephalopathy (n = 1), and cardiac failure (n = 1). Three of the 26 patients had late-onset TIPSS occlusion (at 12, 12, and 39 months after TIPSS creation). Three patients died within one week after the procedure due to their poor general condition (multiorgan failure, acute respiratory distress syndrome, necrotizing pancreatitis, and aspiration pneumonia). Another four patients succumbed to their underlying advanced liver disease within one year after TIPSS insertion. Seven patients underwent OLT at a mean time of 9.4 months after TIPSS creation. The sinus-SuperFlex-Visual stent system can be safely deployed as a TIPSS device. The pressure gradient reduction was clinically sufficient to treat the patients' symptoms, and periprocedural complications were due to the TIPSS procedure per se rather than to the particular stent system employed in this study.
Results From the VISIBILITY Iliac Study: Primary and Cohort Outcomes at 9 Months.
Rundback, John H; Peeters, Patrick; George, Jon C; Jaff, Michael R; Faries, Peter L
2017-06-01
To evaluate the safety and effectiveness of primary stenting of the common (CIA) or external iliac artery (EIA) using the Visi-Pro Balloon-Expandable Peripheral Stent System for treatment of stenotic, restenotic, or occluded lesions. Between 2011 and 2012, 75 patients (mean age 64.2±8.9 years; 46 men) with Rutherford category 2-4 ischemia and atherosclerotic lesions ≤10 cm in length underwent iliac artery stenting at 17 centers in the United States and Europe. The primary outcome of the study was the major adverse event (MAE) rate at 9 months postprocedure [composite of periprocedural death, in-hospital myocardial infarction, clinically driven target lesion revascularization (CD-TLR), and amputation of the treated limb]. Secondary outcomes included 30-day MAE rate, 9-month primary patency, changes in ankle-brachial index (ABI) and the Walking Impairment Questionnaire at 30 days and 9 months postprocedure, device success, and clinically driven target vessel revascularization (CD-TVR) at 30 days and 9 months. Outcomes in specific patient cohorts (ie, gender, stent location, calcification severity, and lesion grade) were analyzed. Eighty-one stents were implanted in 61 CIA and 15 EIA lesions (41 with moderate/severe calcification). The mean lesion treated length was 29.3±13.9 mm. All devices were successfully deployed. MAE occurred in 3 (4.0%) of 75 subjects at 9 months. Primary patency and freedom from CD-TVR at 9 months were both 95.8%. ABI improved from 0.67±0.14 at baseline to 0.94±0.14 and 0.96±0.16 at 30 days and 9-month follow-up, respectively (p<0.001 for both). There were no differences with respect to any of the analyzed patient characteristics, including gender. Nine-month results of the VISIBILITY Iliac stent study ( ClinicalTrials.gov identifier NCT01402700) demonstrated safety and effectiveness for the treatment of atherosclerotic CIA and EIA lesions with the Visi-Pro stent across all treated cohorts.
Furukawa, Nobuyuki; Scholtz, Werner; Haas, Nikolaus; Ensminger, Stephan; Gummert, Jan; Börgermann, Jochen
2015-01-01
An 81-year-old man with high-grade aortic valve stenosis and status post-coronary artery bypass grafting and supracoronary replacement of the ascending aorta was referred for transcatheter aortic valve implantation. He was in New York Heart Association class III and had dyspnea. After appropriate screening, we implanted a 29-mm SAPIEN XT valve (Edwards Lifesciences, Irvine, CA USA) through a transapical approach because of severe peripheral arterial occlusive disease. Postinterventional aortography revealed correct positioning and function of the valve and free coronary ostia but contrast extravasation in the vicinity of the interposed vascular prosthesis, resulting in severe luminal narrowing. We chose to manage the stenosis with an endovascular stent. After stenting, extravascular compression was markedly reduced, and the pressure gradient disappeared. The patient was discharged home on the 20th postoperative day. Three months later, computed tomography depicted correct positioning of both grafts. The patient's general health is good, and he is now in New York Heart Association class II. This case illustrates a complication of transcatheter aortic valve implantation specific for patients with an ascending aortic graft. Although stenting may be a good solution, as depicted by this case, self-expanding transcatheter aortic valves should be preferred in patients with ascending aortic grafts to avoid the described complication.
Müller-Hülsbeck, S; Jahnke, T; Grimm, J; Behm, C; Hilbert, C; Frahm, C; Biederer, J; Brossmann, J; Heller, M
2002-03-01
To evaluate the technical feasibility of a new monorail-stent-balloon device for treatment of renal artery stenosis (RAS). During a study period of 18 months, 38 patients with proven RAS in 41 cases (hypertension n = 36, renal insufficiency n = 13) and indication for stenting (calicified ostial lesions n = 35, insufficient PTA n = 4, dissection n = 2) were enrolled into this prospective evaluation. Pre-mounted stents (Rx-Herculink(TM) 5 mm = 13, 6 mm = 34, 7 mm = 1) were implanted a transfemoral (n = 35) or transbrachial approach (n = 6). Mean grade and lengths of stenosis measured were 88 % plus minus 10 and 9 mm plus minus 5. Renal stent implantation was technically successful in all cases (100 %). In 7 cases a second stent had to be implanted to cover the entire lesion. The transstenotic pressure drop decreased from 88 mmHg plus minus 10 before to 1 mmHg plus minus 1.8 after the procedure. Remaining stenosis measured 0.7 % plus minus 4.2. Serum creatine levels decreased from 1.9 mm/dl to 1.5 mg/dl (n. s.), blood pressure decreased from 178/94 mmHg to 148/79 mmHg (p < 0.0001) after the intervention. Primary and secondary patency rates at 6 months were 72 % (Standard Error 9.8 %) and 77 (% (Standard Error 9.2 %), respectively. With the used monorail-stend-balloon device a technically easy, secure and exact renal stent placement is guaranteed, patency rates are similar to those described in the current literature.
Gil, Robert J; Vassilev, Dobrin; Formuszewicz, Radoslaw; Rusicka-Piekarz, Teresa; Doganov, Alexander
2009-12-01
The two main problems unresolved in coronary bifurcation stenting are periprocedural side branch compromise and higher restenosis at long term. The purpose of this study is to reveal the link between periprocedural side branch compromise and long-term results after main vessel stenting only in coronary bifurcations. Eighty-four patients formed the study population. The inclusion criteria were good-quality angiograms, with maximal between-branch angle opening, no overlap, permitting accurate angiographic analysis. Carina angle (alpha)-the distal angle between main vessel (MV) before bifurcation and side branch (SB)-was measured pre- and poststenting. Clinical follow-up 9-12 months was obtained with coronary angiography if needed. The patient population was high-risk with 33% diabetics and 84% two- and three-vessel disease. Ninety-five stents were implanted in 92 lesions, with three T-stenting cases. Drug-eluting stents were implanted in 54%. Kissing-balloon (KBI) or sequential inflation was performed in 35%. SB functional closure occurred in 17.4%, with independent predictors alpha < 40 degrees and diameter ratio MB/SB >1.22. After 12+/-4 months there were five myocardial infarctions (6%) and 13 (15%) target lesion revascularization procedures. Independent predictors of major cardiovascular events were carina angle <40 degrees , MB lesion length >8 mm, negative change of between-branch angle, DES usage, and KBI. Smaller carina angle with straightening of MV-main branch from stent implantation in coronary bifurcations predicted higher SB compromise, restenosis, and MACE rates during follow-up of 1 year.
Delayed Esophageal Hemorrhage Caused by a Metal Stent: Treatment with Embolization
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kos, Xavier; Trotteur, Genevieve; Dondelinger, Robert F.
We report a case of life-threatening esophageal hemorrhage after metal stent implantation successfully treated by arterial embolization. An 85-year-old woman was admitted in shock secondary to massive hematemesis and melena. Recent medical history revealed esophageal cancer treated 8 weeks previously by endoesophageal radiotherapy (40 Gy) and endoscopic placement of a covered Wallstent prosthesis. Selective arteriography of the fifth posterior right intercostal artery showed massive contrast extravasation in the esophagus. Embolization was performed with 150-250-{mu}m polyvinyl alcohol particles. Follow-up at 5 months was uneventful. Arteriography and embolization are advised when severe hemorrhage occurs after esophageal implantation of metal stents.
Paprottka, Karolin J.; Paprottka, Philipp M.; Reiser, Maximilian F.; Waggershauser, Tobias
2015-01-01
PURPOSE Clinical cases of stent-fractures show that corrosion behavior might play a role in these fractures. Implanted in vivo, especially in combination with other implanted foreign materials, these metallic products are exposed to special conditions, which can cause a process of corrosion. Here, we aimed to test the corrosion potential of stents made of different materials in an in vitro setting. METHODS A total of 28 peripheral stents of different materials (nitinol, cobalt-chromium-nickel, tantalum, V4A) and surface treatments (electropolish, mechanical polish, no polish) were tested in vitro. Corrosion was accelerated by applying a constant voltage of 3.5 V and amperage of 1.16 mA in 0.9% NaCl. RESULTS Nitinol stents showed the lowest susceptibility to corrosion and the longest period without damage. The Memotherm II® (BARD Angiomed®) was the only stent that showed neither macroscopic nor microscopic damages. The worst performing material was cobalt-chromium-nickel, which showed corrosion damages about ten times earlier compared to nitinol. Considering the reasons for termination of the test, nitinol stents primarily showed length deficits, while V4A and tantalum stents showed fractures. Cobalt-chromium-nickel stents had multiple fractures or a complete lysis in equal proportions. When placed in direct contact, nitinol stents showed best corrosion resistance, regardless of what material they were combined with. In terms of polishing treatments, electropolished stents performed the best, mechanical-polished stents and those without polishing treatment followed. CONCLUSION The analysis of corrosion behavior may be useful to select the right stent fulfilling the individual needs of the patient within a large number of different stents. PMID:26268301
2018-01-01
Objectives To assess the placement, surveillance management and long-term outcomes of the tracheobronchial (TB) balloon expandable metallic stent (BEMS) managed by therapeutic flexible endoscopy (TFE). Methods This is a retrospective review and analysis of all computerized medical records and related flexible endoscopy videos of pediatric patients who received TB BEMS during 20 years period, from January 1997 to December 2016. TFE techniques with forceps debridement, balloon dilatation and laser ablation were used to implant stents, perform regular surveillance, maintain their functions, and expand the diameters of BEMS. Short-length (30cm-36cm) endoscopes of OD 3.2mm to 5.0mm coupled with the noninvasive ventilation, without ventilation bag, mask or airway tube, supported the whole procedures. Results 146 BEMS were implanted in 87 consecutive children, including 84 tracheal, 15 carinal and 47 bronchial stents. At the time of placement, the mean age was 35.6 ± 54.6 month-old (range 0.3–228) and the mean body weight was 13.9 ± 10.6 kg (range 2.2–60). Surveillance period was 9.4 ± 6.7 years (range, 0.3–18.0). Satisfactory clinical improvements were noted immediately in all but two patients. Seventy-two (82.8%) patients were still alive with stable respiratory status, except two patients necessitating TFE management every two months. Fifty-one stents, including 35 tracheal and 16 bronchial ones, were successfully retrieved mainly with rigid endoscopy. Implanted stents could be significantly (< .001) further expanded for growing TB lumens. The final stent diameters were positively correlated to the implanted duration. Altogether, 33 stents expired (15 patients), 51 were retrieved (40 patients), and 62 remained and functioning well (38 patients), with their mean duration of 7.4 ± 9.5, 34.9 ± 36.3 and 82.3 ± 62.5 months, respectively. Conclusion In pediatric patients, TFE with short-length scopes coupled with this NIV support has provided a safe, feasible and effective modality in placing and subsequently managing TB BEMS with acceptable long-term outcomes. PMID:29420596
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sochman, Jan; Peregrin, Jan H.; Rocek, Miloslav
Purpose. To evaluate the feasibility of one-step implantation of a new type of stent-based mechanical aortic disc valve prosthesis (MADVP) above and across the native aortic valve and its short-term function in swine with both functional and dysfunctional native valves. Methods. The MADVP consisted of a folding disc valve made of silicone elastomer attached to either a nitinol Z-stent (Z model) or a nitinol cross-braided stent (SX model). Implantation of 10 MADVPs (6 Z and 4 SX models) was attempted in 10 swine: 4 (2 Z and 2 SX models) with a functional native valve and 6 (4 Z andmore » 2 SX models) with aortic regurgitation induced either by intentional valve injury or by MADVP placement across the native valve. MADVP function was observed for up to 3 hr after implantation. Results. MADVP implantation was successful in 9 swine. One animal died of induced massive regurgitation prior to implantation. Four MADVPs implanted above functioning native valves exhibited good function. In 5 swine with regurgitation, MADVP implantation corrected the induced native valve dysfunction and the device's continuous good function was observed in 4 animals. One MADVP (SX model) placed across native valve gradually migrated into the left ventricle. Conclusion. The tested MADVP can be implanted above and across the native valve in a one-step procedure and can replace the function of the regurgitating native valve. Further technical development and testing are warranted, preferably with a manufactured MADVP.« less
Acute ST-Elevation Myocardial Infarction after Coronary Stent Fracture.
Rafighdust, Abbasali; Eshraghi, Ali
2015-10-27
The invention of the drug-eluting stent (DES) has brought about revolutionary changes in the field of interventional cardiology. In the DES era, in-stent restenosis has declined but new issues such as stent thrombosis have emerged. One of the emerging paradigms in the DES era is stent fracture. There are reports about stent fracture leading to in-stent restenosis or stent thrombosis. Most of these reports concern the Sirolimus-eluting stent. The present case is a representation of a Biolimus-eluting stent fracture. We introduce a 64-year-old male patient, for whom the BioMatrix stent was deployed in the right coronary artery. Five months after the implantation, he experienced acute myocardial infarction, with stent fracture leading to stent thrombosis being the causative mechanism. Another DES (Cypher) was used to manage this situation, and the final result was good.
Stent implantation influence wall shear stress evolution
NASA Astrophysics Data System (ADS)
Bernad, S. I.; Totorean, A. F.; Bosioc, A. I.; Petre, I.; Bernad, E. S.
2016-06-01
Local hemodynamic factors are known affect the natural history of the restenosis critically after coronary stenting of atherosclerosis. Stent-induced flows disturbance magnitude dependent directly on the strut design. The impact of flow alterations around struts vary as the strut geometrical parameters change. Our results provide data regarding the hemodynamic parameters for the blood flow in both stenosed and stented coronary artery under physiological conditions, namely wall shear stress and pressure drop.
Chen, Mounter C Y; Lu, Po-Chien; Chen, James S Y; Hwang, Ned H C
2005-01-01
Coronary stents are supportive wire meshes that keep narrow coronary arteries patent, reducing the risk of restenosis. Despite the common use of coronary stents, approximately 20-35% of them fail due to restenosis. Flow phenomena adjacent to the stent may contribute to restenosis. Three-dimensional computational fluid dynamics (CFD) and reconstruction based on biplane cine angiography were used to assess coronary geometry and volumetric blood flows. A patient-specific left anterior descending (LAD) artery was reconstructed from single-plane x-ray imaging. With corresponding electrocardiographic signals, images from the same time phase were selected from the angiograms for dynamic three-dimensional reconstruction. The resultant three-dimensional LAD artery at end-diastole was adopted for detailed analysis. Both the geometries and flow fields, based on a computational model from CAE software (ANSYS and CATIA) and full three-dimensional Navier-Stroke equations in the CFD-ACE+ software, respectively, changed dramatically after stent placement. Flow fields showed a complex three-dimensional spiral motion due to arterial tortuosity. The corresponding wall shear stresses, pressure gradient, and flow field all varied significantly after stent placement. Combined angiography and CFD techniques allow more detailed investigation of flow patterns in various segments. The implanted stent(s) may be quantitatively studied from the proposed hemodynamic modeling approach.
Shan, Hong; Xiao, Xiang-Sheng; Huang, Ming-Sheng; Ouyang, Qiang; Jiang, Zai-Bo
2005-06-07
To evaluate the value of endovascular stent in the treatment of portal hypertension caused by benign main portal vein stenosis. Portal vein stents were implanted in six patients with benign main portal vein stenosis (inflammatory stenosis in three cases, postprocedure of liver transplantation in another three cases). Changes in portal vein pressure, portal vein patency, relative clinical symptoms, complications, and survival were evaluated. Six metallic stents were successfully placed across the portal vein stenotic or obstructive lesions in six patients. Mean portal venous pressure decreased significantly after stent implantation from (37.3+/-4.7) cm H(2)O to (18.0+/-1.9) cm H(2)O. The portal blood flow restored and the symptoms caused by portal hypertension were eliminated. There were no severe procedure-related complications. The patients were followed up for 1-48 mo. The portal vein remained patent during follow-up. All patients survived except for one patient who died of other complications of liver transplantation. Percutaneous portal vein stent placement for the treatment of portal hypertension caused by benign main portal vein stenosis is safe and effective.
Balzer, Jörn O; Gastinger, Verena; Thalhammer, Axel; Ritter, Ralf G; Lindhoff-Last, Edelgard; Schmitz-Rixen, Thomas; Vogl, Thomas J
2006-02-01
We report the primary and mid-term outcome of patients with long chronic iliac artery occlusions after percutaneous excimer-laser-assisted interventional recanalization. Between 2000 and 2001, 43 patients with 46 chronic occlusions of either the common iliac artery (n=27), the external iliac artery ( n=13) or both (n=3) underwent laser-assisted percutaneous transluminal angioplasty and implantation of stents. The average length of the occlusion was 57.1+/-26 mm. After laser-assisted angioplasty and implantation of a total of 60 stents, the patients were followed up for up to 4 years. Patency rates were analyzed by ankle-brachial index (ABI) measurement and duplex ultrasound. The primary technical success rate was 95.3%, with a major complication rate of 6.9%. Clinical improvement as categorized by the Rutherford guidelines could be observed in 97.6% of cases. The ABI of all patients improved from an average of 0.46+/-0.08 before intervention to 0.97+/-0.13 at the end of the follow-up period. The overall primary patency rate was 86.1%. Four reinterventions were successful (secondary patency rate 95.4%). The mid-term results of the percutaneous recanalization of iliac artery occlusions with primary and secondary patency rates of 86.1 and 95.4% are similar to those of the treatment of short stenoses.
Yan, Qiao; Changsheng, Ma; Shaoping, Nie; Xiaohui, Liu; Junping, Kang; Qiang, Lv; Xin, Du; Rong, Hu; Yin, Zhang; Changqi, Jia; Jiahui, Wu; Xinmin, Liu; Jianzeng, Dong; Fang, Chen; Yujie, Zhou; Shuzheng, Lv; Fangjiong, Huang; Chengxiong, Gu; Xuesi, Wu
2009-10-01
The aim of the present study was to compare the effects of drug-eluting stents (DES) and coronary artery bypass grafting (CABG) in patients suffering from chronic stable angina with multivessel disease, involving significant proximal stenosis in the left anterior descending artery (LAD). All consecutive patients suffering from chronic stable angina with multivessel disease involving significant proximal LAD stenosis underwent DES implantation (n=600) or CABG (n=709) at our institution. At 2 years, the unadjusted mortality was significantly lower in the DES group than in the CABG group (2.2% vs 5.2%, P=0.004), but the adjusted risk of death was similar (odds ratio (OR) 0.74, 95%CI 0.28-1.97, P=0.555). Furthermore, both the adjusted rate of nonfatal myocardial infarction and cerebrovascular events was also comparable. However, the unadjusted and adjusted risk of major adverse cardiac cerebrovascular events in the DES was significantly higher than in the CABG (13.3% vs 9.6%, OR 2.71, 95%CI 1.56-4.74, P<0.001), which is probably attributed to the higher subsequent revascularization rate after DES implantation. DES showed comparable long-term mortality for the treatment of multivessel disease involving significant proximal stenosis in LAD in comparison with CABG.
Dahm, J B; Ruppert, J; Hartmann, S; Vogelgesang, D; Hummel, A; Felix, S B
2006-01-01
Objectives To examine by retrospective analysis of data from the FLEXI‐CUT monocentre registry whether atherectomy can effectively simplify complex stent implantation in ostial bifurcation lesions by reducing the procedure to stenting of the left anterior descending (LAD) or left circumflex (LCX) artery ostium alone. Patients and methods All patients who had been enrolled in the prospective FLEXI‐CUT study (directional atherectomy with adjunctive balloon angioplasty) were retrospectively analysed on the basis of significant LAD or LCX ostial stenosis (⩾ 70% stenosis) deriving from an undiseased left main stem. The primary combined end point was the rate of target lesion revascularisation (TLR) and binary restenosis; secondary end points were procedural success and major adverse cardiac events (MACE) at the six‐month follow up. Results Of 30 patients enrolled with significant LAD or LCX ostium stenosis, 29 were effectively treated with directional atherectomy (96.7% procedural success). All patients underwent single‐vessel stenting procedures of solely the LAD or LCX ostium. At follow up, binary stenosis was 25% (6 of 24), TLR (angiographic plus clinical) 10.3% (3 of 29) and total MACE 6.9% (2 of 29). Conclusions Directional atherectomy with single‐vessel stenting procedures facilitates the interventional treatment of LAD and LCX ostium stenosis, and leads to remarkably low TLR and binary stenosis at follow up. PMID:16449510
Lee, Seung-Yul; Shin, Dong-Ho; Kim, Jung-Sun; Kim, Byeong-Keuk; Ko, Young-Guk; Choi, Donghoon; Jang, Yangsoo
2017-01-01
Purpose To evaluate the effects of sex and anthropometry on clinical outcomes in patients who underwent percutaneous coronary intervention (PCI). Materials and Methods From three randomized trials (REal Safety and Efficacy of 3-month dual antiplatelet Therapy following Endeavor zotarolimus-eluting stent implantation, Impact of intraVascular UltraSound guidance on outcomes of Xience Prime stents in Long lesions, Chronic Total Occlusion InterVention with drUg-eluting Stents), we compared 333 pairs of men and women matched by propensity scores, all of whom underwent intravascular ultrasound (IVUS)-guided PCI for complex lesions. Results For 12 months, the incidence of adverse cardiac events, defined as the composite of cardiac death, target lesion–related myocardial infarction, and target lesion revascularization, was not different between women and men (2.4% vs. 2.4%, p=0.939). Using multivariable Cox's regression analysis, post-intervention minimum lumen area [MLA; hazard ratio (HR)=0.620, 95% confidence interval (CI)=0.423–0.909, p=0.014] by IVUS was a predictor of adverse cardiac events. Height on anthropometry and lesions with chronic total occlusion were significantly related to post-intervention MLA. However, female sex was not independently associated with post-intervention MLA. In an age and sex-adjusted model, patients in the low tertile of height exhibited a greater risk for adverse cardiac events than those in the high tertile of height (HR=6.391, 95% CI=1.160–35.206, p=0.033). Conclusion Sex does not affect clinical outcomes after PCI for complex lesions. PCI outcomes, however, may be adversely affected by height. PMID:28120559
Kida, M; Miyazawa, S; Iwai, T; Ikeda, H; Takezawa, M; Kikuchi, H; Watanabe, M; Imaizumi, H; Koizumi, W
2011-12-01
Recent progress in chemotherapy has prolonged the survival of patients with malignant biliary strictures, leading to increased rates of stent occlusion. Occlusion of covered metallic stents now occurs in about half of all patients with malignant biliary strictures. The removal of metallic stents followed by placement of a second stent has been attempted, but outcomes remain controversial. The aim of the current study was to evaluate the effectiveness and safety of the primary placement and secondary placement (re-intervention) of covered metallic stents and to assess the feasibility and safety of stent removal. The study included 186 patients with unresectable malignant biliary strictures who underwent primary stent placement between October 2001 and March 2010. Covered biliary self-expandable metal stents (SEMSs) were removed in 39 of these patients, and 36 underwent re-intervention. The patency times, occlusion rates of the first stent and re-intervention, success rates of stent removal, and complications were investigated. Covered SEMSs were placed in 186 patients. The median patency time of the first stent was 352 days. Stent occlusion occurred in 48.9 % of the patients and was mainly caused by debris or food residue (37 %), dislocation (19 %), and migration with hyperplasia (19 %). Stent removal was attempted in 50 patients and was successful without complication in 39 (78 %). Most of the patients in whom stent removal was unsuccessful had migration with hyperplasia. The median patency time of the second stent was 263 days. The stent patency time did not significantly differ between the first and the second stent. Covered SEMSs could be safely removed at the time of stent occlusion. Patency rates were similar for initial stent placement and re-intervention. © Georg Thieme Verlag KG Stuttgart · New York.
[Sixteen Cases of Colon Stenting as a Bridge to Surgery(BTS)for Obstructive Colorectal Cancer].
Otsuka, Ryo; Saito, Shuji; Hirayama, Ryouichi; Miura, Yasuaki; Sasaki, Kazunori; Miyajima, Ayako; Kuwamoto, Nobutsuna; Kataoka, Ryoko; Shindo, Yukito; Fujita, Rikiya
2017-11-01
Colonic stent insertion is widely used as a bridge to surgery(BTS)for obstructive colorectal cancer. Stenting can shorten hospitalization and decrease complication and colostomy rates in comparison with emergency surgery. We investigated patients who underwent colonic stent insertion for BTS in our hospital. Sixteen patients(8 men, 8 women) with a colorectal obstruction score of 0 or 1 who underwent colonic stent insertion as a BTS between April 2015 and April 2017 period were investigated. Mean patient age was 68.2(45-94)years. Technical success was obtained in all patients, and clinical success in 14(87%). Total colonoscopy was possible via stent in 10 patients. Nine patients were temporarily discharged from the hospital, and median time to operation was 18(2-43)days. Laparoscopic resection was performed in 14 patients, and anastomotic leakage was a postoperative complication in 1 patient. Colostomy was performed in only 1 patient with anastomotic leakage. Good results were obtained with careful patient selection and safe colonic stent insertion.
Bioresorbable scaffolds for percutaneous coronary interventions
Gogas, Bill D.
2014-01-01
Innovations in drug-eluting stents (DES) have substantially reduced rates of in-segment restenosis and early stent thrombosis, improving clinical outcomes following percutaneous coronary interventions (PCI). However a fixed metallic implant in a vessel wall with restored patency and residual disease remains a precipitating factor for sustained local inflammation, in-stent neo-atherosclerosis and impaired vasomotor function increasing the risk for late complications attributed to late or very late stent thrombosis and late target lesion revascularization (TLR) (late catch-up). The quest for optimal coronary stenting continues by further innovations in stent design and by using biocompatible materials other than cobalt chromium, platinum chromium or stainless steel for engineering coronary implants. Bioresorbable scaffolds made of biodegradable polymers or biocorrodible metals with properties of transient vessel scaffolding, local drug-elution and future restoration of vessel anatomy, physiology and local hemodynamics have been recently developed. These devices have been utilized in selected clinical applications so far providing preliminary evidence of safety showing comparable performance with current generation drug-eluting stents (DES). Herein we provide a comprehensive overview of the current status of these technologies, we elaborate on the potential benefits of transient coronary scaffolds over permanent stents in the context of vascular reparation therapy, and we further focus on the evolving challenges these devices have to overcome to compete with current generation DES. Condensed Abstract:: The quest for optimizing percutaneous coronary interventions continues by iterative innovations in device materials beyond cobalt chromium, platinum chromium or stainless steel for engineering coronary implants. Bioresorbable scaffolds made of biodegradable polymers or biocorrodible metals with properties of transient vessel scaffolding; local drug-elution and future restoration of vessel anatomy, physiology and local hemodynamics were recently developed. These devices have been utilized in selected clinical applications providing preliminary evidence of safety showing comparable intermediate term clinical outcomes with current generation drug-eluting stents. PMID:25780795
A review of stent’s failure on patent ductus arteriosus
NASA Astrophysics Data System (ADS)
Lazim, Zulfaqih; Ismail, Al Emran; Taib, Ishkrizat; Atan, Bainun Akmal Mohd
2017-01-01
This paper presents a review of stent’s failure on patent ductus arteriosus (PDA). Ductus arteriosus (DA) is an opening for newborn babies and some patient that experienced cynotic congenital heart disease (CCHD) should maintain the duct opening for survival. To date, there are no specific research on mechanical stent failure study at DA. The challenging of the stent implantation on PDA is the PDA morphology. The failure of stent in term of stent fracture have been reported and reviewed in this paper. Furthermore, the failure prediction of stent is important for further stent design development. The morphology of PDA, stent type and material used in PDA and method for accessing the failure of stent is reviewed.
Evaluating the interaction of a tracheobronchial stent in an ovine in-vivo model.
McGrath, Donnacha J; Thiebes, Anja Lena; Cornelissen, Christian G; O'Brien, Barry; Jockenhoevel, Stefan; Bruzzi, Mark; McHugh, Peter E
2018-04-01
Tracheobronchial stents are used to restore patency to stenosed airways. However, these devices are associated with many complications such as stent migration, granulation tissue formation, mucous plugging and stent strut fracture. Of these, granulation tissue formation is the complication that most frequently requires costly secondary interventions. In this study a biomechanical lung modelling framework recently developed by the authors to capture the lung in-vivo stress state under physiological loading is employed in conjunction with ovine pre-clinical stenting results and device experimental data to evaluate the effect of stent interaction on granulation tissue formation. Stenting is simulated using a validated model of a prototype covered laser-cut tracheobronchial stent in a semi-specific biomechanical lung model, and physiological loading is performed. Two computational methods are then used to predict possible granulation tissue formation: the standard method which utilises the increase in maximum principal stress change, and a newly proposed method which compares the change in contact pressure over a respiratory cycle. These computational predictions of granulation tissue formation are then compared to pre-clinical stenting observations after a 6-week implantation period. Experimental results of the pre-clinical stent implantation showed signs of granulation tissue formation both proximally and distally, with a greater proximal reaction. The standard method failed to show a correlation with the experimental results. However, the contact change method showed an apparent correlation with granulation tissue formation. These results suggest that this new method could be used as a tool to improve future device designs.
Mischke, Karl; Knackstedt, Christian; Marx, Nikolaus
2012-01-01
Anticoagulation represents the mainstay of therapy for most patients with atrial fibrillation. Patients on oral anticoagulation often require concomitant antiplatelet therapy, mostly because of coronary artery disease. After coronary stent implantation, dual antiplatelet therapy is necessary. However, the combination of oral anticoagulation and antiplatelet therapy increases the bleeding risk. Risk scores such as the CHA2DS2-Vasc score and the HAS-BLED score help to identify both bleeding and stroke risk in individual patients. The guidelines of the European Society of Cardiology provide a rather detailed recommendation for patients on oral anticoagulation after coronary stent implantation. However, robust evidence is lacking for some of the recommendations, and especially for new oral anticoagulants and new antiplatelets few or no data are available. This review addresses some of the critical points of the guidelines and discusses potential advantages of new anticoagulants in patients with atrial fibrillation after stent implantation. PMID:22577538
Sharaiha, Reem Z; Kumta, Nikhil A; DeFilippis, Ersilia M; Dimaio, Christopher J; Gonzalez, Susana; Gonda, Tamas; Rogart, Jason; Siddiqui, Ali; Berg, Paul S; Samuels, Paul; Miller, Larry; Khashab, Mouen A; Saxena, Payal; Gaidhane, Monica R; Tyberg, Amy; Teixeira, Julio; Widmer, Jessica; Kedia, Prashant; Loren, David; Kahaleh, Michel; Sethi, Amrita
2016-01-01
To describe a multicenter experience using an endoscopic suturing device for management of gastrointestinal (GI) defects and stent anchorage. Endoscopic closure of GI defects including perforations, fistulas, and anastomotic leaks as well as stent anchorage has improved with technological advances. An endoscopic suturing device (OverStitch; Apollo Endosurgery Inc.) has been used. Retrospective study of consecutive patients who underwent endoscopic suturing for management of GI defects and/or stent anchorage were enrolled between March 2012 and January 2014 at multiple academic medical centers. Data regarding demographic information and outcomes including long-term success were collected. One hundred and twenty-two patients (mean age, 52.6 y; 64.2% females) underwent endoscopic suturing at 8 centers for stent anchorage (n=47; 38.5%), fistulas (n=40; 32.7%), leaks (n=15; 12.3%), and perforations (n=20; 16.4%). A total of 44.2% underwent prior therapy and 97.5% achieved technical success. Immediate clinical success was achieved in 79.5%. Long-term clinical success was noted in 78.8% with mean follow-up of 68 days. Clinical success was 91.4% in stent anchorage, 93% in perforations, 80% in fistulas, but only 27% in anastomotic leak closure. Endoscopic suturing for management of GI defects and stent anchoring is safe and efficacious. Stent migration after stent anchoring was reduced compared with published data. Long-term success without further intervention was achieved in the majority of patients. The role of endoscopic suturing for repair of anastomotic leaks remains unclear given limited success in this retrospective study.
Anton, Susanne; Oechtering, T; Stahlberg, E; Jacob, F; Kleemann, M; Barkhausen, J; Goltz, J P
2018-06-01
The aim of this paper is to evaluate the safety and efficacy of endovascular revascularization of malignant superior vena cava syndrome (SVCS) and simultaneous implantation of a totally implantable venous access port (TIVAP) using a dual venous approach. Retrospectively, 31 patients (mean age 67 ± 8 years) with malignant CVO who had undergone revascularization by implantation of a self-expanding stent into the superior vena cava (SVC) (Sinus XL®, OptiMed, Germany; n = 11 [Group1] and Protégé ™ EverFlex, Covidien, Ireland; n = 20 [Group 2]) via a transfemoral access were identified. Simultaneously, percutaneous access via a subclavian vein was used to (a) probe the lesion from above, (b) facilitate a through-and-through maneuver, and (c) implant a TIVAP. Primary endpoints with regard to the SVC syndrome were technical (residual stenosis < 30%) and clinical (relief of symptoms) success; with regard to TIVAP implantation technical success was defined as positioning of the functional catheter within the SVC. Secondary endpoints were complications as well as stent and TIVAP patency. Technical and clinical success rate were 100% for revascularization of the SVS and 100% for implantation of the TIVAP. One access site hematoma (minor complication, day 2) and one port-catheter-associated sepsis (major complication, day 18) were identified. Mean catheter days were 313 ± 370 days. Mean imaging follow-up was 184 ± 172 days. Estimated patency rates at 3, 6, and 12 months were 100% in Group 1 and 84, 84, and 56% in Group 2 (p = 0.338). Stent-based revascularization of malignant SVCS with concomitant implantation of a port device using a dual venous approach appears to be safe and effective.
Han, Jae Pil; Hong, Su Jin; Kim, Shin Hee; Choi, Jong Hyo; Jung, Hee Jae; Cho, Youn Hee; Ko, Bong Min; Lee, Moon Sung
2014-08-01
Self-expandable metal stents (SEMSs) have been used as palliative treatment or bridge to surgery for obstructions caused by colorectal cancer (CRC). We assessed the long-term outcomes of palliative SEMSs and evaluated the risk factors influencing complications. One hundred and seventy-five patients underwent SEMS placement for acute malignant colorectal obstruction. Of the 72 patients who underwent palliative treatment for primary CRC, 30 patients received chemotherapy (CT) for primary cancer (CT group) and 42 underwent best supportive treatment (BST) without CT (BST group). There was a significant difference in late migration between the CT group and the BST group (20.0% in CT group, 2.4% in BST group, p = 0.018). Response to CT influenced the rate of late obstruction (0% in disease control, 35.7% in disease progression, p = 0.014). However, late obstruction was not associated with stent properties, such as diameter or type (≤22 mm vs. >22 mm, 13.5% vs. 14.3%, p = 1.00; uncovered stent vs. covered stent, 15.5% vs. 7.1%, p = 0.675) and migration (≤22 mm vs. >22 mm, 16.2% vs. 2.9%, p = 0.108; uncovered stent vs. covered stent, 8.6% vs. 14.3%, p = 0.615) in palliative SEMS. The administration of CT increases the rate of stent migration, and disease control by CT can reduce the risk of obstruction by maintaining the luminal patency of palliative SEMSs.
Erb, Carl; Carceller Guillamet, Amadeu; Fea, Antonio M; Voskanyan, Lilit; Giamporcaro, Jane Ellen; Hornbeak, Dana M
2018-01-01
Purpose Evaluate long-term outcomes after one, two, or three trabecular micro-bypass stents implanted in a standalone procedure in eyes with open-angle glaucoma taking ocular hypotensive medication. Patients and methods Prospective randomized ongoing study of 119 subjects (109 with 42-month follow-up) with open-angle glaucoma, preoperative intraocular pressure (IOP) 18–30 mmHg on one to three glaucoma medications, and unmedicated (post-washout) IOP 22–38 mmHg. Subjects were randomized to receive one (n=38), two (n=41), or three (n=40) iStent trabecular micro-bypass stents in a standalone procedure. Postoperatively, IOP was measured with medication and annually following washout. Data included IOP, medications, gonioscopy, pachymetry, visual field, visual acuity, adverse events, and slit-lamp and fundus examinations. Results Preoperative mean medicated IOP was 19.8±1.3 mmHg on 1.71 medications in one-stent eyes, 20.1±1.6 mmHg on 1.76 medications in two-stent eyes, and 20.4±1.8 mmHg on 1.53 medications in three-stent eyes. Post-washout IOP prior to stent implantation was 25.0±1.2, 25.0±1.7, and 25.1±1.9 mmHg in the three groups, respectively. Postoperatively, Month 42 medicated IOP was 15.0±2.8, 15.7±1.0 and 14.8±1.3 mmHg in the three groups, and post-washout IOP (Months 36–37) was 17.4±0.9, 15.8±1.1 and 14.2±1.5 mmHg, respectively. IOP reduction ≥20% without medication was achieved in 89%, 90%, and 92% of one-, two-, and three-stent eyes, respectively, at Month 12; and in 61%, 91%, and 91% of eyes, respectively, at Month 42. The need for additional medication remained consistent at Months 12 and 42 in multi-stent eyes (four two-stent eyes and three three-stent eyes at both time points), whereas it increased in single-stent eyes (four eyes at Month 12 versus 18 eyes at Month 42). Safety parameters were favorable in all groups. Conclusion The standalone implantation of either single or multiple iStent® device(s) produced safe, clinically meaningful IOP and medication reductions through 42 months postoperatively, with incrementally greater and more sustained reductions in multi-stent eyes. PMID:29440867
Computational Analysis on Stent Geometries in Carotid Artery: A Review
NASA Astrophysics Data System (ADS)
Paisal, Muhammad Sufyan Amir; Taib, Ishkrizat; Ismail, Al Emran
2017-01-01
This paper reviews the work done by previous researchers in order to gather the information for the current study which about the computational analysis on stent geometry in carotid artery. The implantation of stent in carotid artery has become popular treatment for arterial diseases of hypertension such as stenosis, thrombosis, atherosclerosis and embolization, in reducing the rate of mortality and morbidity. For the stenting of an artery, the previous researchers did many type of mathematical models in which, the physiological variables of artery is analogized to electrical variables. Thus, the computational fluid dynamics (CFD) of artery could be done, which this method is also did by previous researchers. It lead to the current study in finding the hemodynamic characteristics due to artery stenting such as wall shear stress (WSS) and wall shear stress gradient (WSSG). Another objective of this study is to evaluate the nowadays stent configuration for full optimization in reducing the arterial side effect such as restenosis rate after a few weeks of stenting. The evaluation of stent is based on the decrease of strut-strut intersection, decrease of strut width and increase of the strut-strut spacing. The existing configuration of stents are actually good enough in widening the narrowed arterial wall but the disease such as thrombosis still occurs in early and late stage after the stent implantation. Thus, the outcome of this study is the prediction for the reduction of restenosis rate and the WSS distribution is predicted to be able in classifying which stent configuration is the best.
Simka, Marian; Brzegowy, Paweł; Janas, Piotr; Kazibudzki, Marek; Pieniążek, Piotr; Ochała, Andrzej; Popiela, Tadeusz; Mrowiecki, Tomasz
2017-01-01
Introduction Although surgical endarterectomy remains the treatment of choice for carotid artery stenosis, stenting plays an important role as an alternative treatment modality, especially in high-risk patients. The actual safety profile associated with stenting procedures is probably better than that reported by randomized controlled trials. Aim To assess the safety of stent implantations in extracranial arteries supplying the brain, and also to identify risk factors associated with this procedure. Material and methods This was a post hoc analysis, with 30-day follow-up. We analyzed the results of treatment of 372 patients who underwent 408 procedures, 197 such procedures in asymptomatic, and 211 in symptomatic individuals. Stenting procedures were performed using a technique and armamentarium which were tailored to the type and anatomy of lesions. Results There were 6 (1.5%) strokes, including 2 (0.5%) major strokes, 1 ipsi- and 1 contralateral, and 4 (1.0%) minor strokes. In asymptomatic patients there was 1 (0.3%) minor stroke. Transient ischemic attacks occurred in 5 (1.2%) patients. There were 2 (0.5%) non-STEMI myocardial infarctions and 2 (0.5%) non-stroke related fatalities. Risk factors of these adverse events were diabetes mellitus, lesions localized in a tortuous segment of the artery, embolic material in the filter and bilateral stenoses of carotid arteries. Additional risk factors in asymptomatic patients were renal impairment and advanced coronary artery disease; and in symptomatic patients, grade 3 arterial hypertension, dislipidemia, cigarette smoking and lesions requiring predilatation. Conclusions Stenting procedures of extracranial arteries supplying the brain, which are tailored to the type and anatomy of lesions, seem to be relatively safe. PMID:28344618
Latacz, Paweł; Simka, Marian; Brzegowy, Paweł; Janas, Piotr; Kazibudzki, Marek; Pieniążek, Piotr; Ochała, Andrzej; Popiela, Tadeusz; Mrowiecki, Tomasz
2017-01-01
Although surgical endarterectomy remains the treatment of choice for carotid artery stenosis, stenting plays an important role as an alternative treatment modality, especially in high-risk patients. The actual safety profile associated with stenting procedures is probably better than that reported by randomized controlled trials. To assess the safety of stent implantations in extracranial arteries supplying the brain, and also to identify risk factors associated with this procedure. This was a post hoc analysis, with 30-day follow-up. We analyzed the results of treatment of 372 patients who underwent 408 procedures, 197 such procedures in asymptomatic, and 211 in symptomatic individuals. Stenting procedures were performed using a technique and armamentarium which were tailored to the type and anatomy of lesions. There were 6 (1.5%) strokes, including 2 (0.5%) major strokes, 1 ipsi- and 1 contralateral, and 4 (1.0%) minor strokes. In asymptomatic patients there was 1 (0.3%) minor stroke. Transient ischemic attacks occurred in 5 (1.2%) patients. There were 2 (0.5%) non-STEMI myocardial infarctions and 2 (0.5%) non-stroke related fatalities. Risk factors of these adverse events were diabetes mellitus, lesions localized in a tortuous segment of the artery, embolic material in the filter and bilateral stenoses of carotid arteries. Additional risk factors in asymptomatic patients were renal impairment and advanced coronary artery disease; and in symptomatic patients, grade 3 arterial hypertension, dislipidemia, cigarette smoking and lesions requiring predilatation. Stenting procedures of extracranial arteries supplying the brain, which are tailored to the type and anatomy of lesions, seem to be relatively safe.
Asher, Elad; Abu-Much, Arsalan; Goldenberg, Ilan; Segev, Amit; Sabbag, Avi; Mazin, Israel; Shlezinger, Meital; Atar, Shaul; Zahger, Doron; Polak, Arthur; Beigel, Roy; Matetzky, Shlomi
2016-01-01
Early stent thrombosis (EST) (≤ 30 days after stent implantation) is a relatively rare but deleterious complication of percutaneous coronary intervention (PCI). Administration of newer P2Y12 inhibitors (prasugrel and ticagrelor) combined with aspirin has been shown to reduce the incidence of sub-acute and late stent thrombosis, compared with clopidogrel. We investigated the “real life” incidence of EST in patients from a large acute coronary syndrome (ACS) national registry, where newer P2Y12 inhibitors are widely used. Patients were derived from the ACS Israeli Survey (ACSIS), conducted during 2006, 2008, 2010 and 2013. Major adverse cardiac events (MACE) at 30days were defined as all-cause death, recurrent ACS, EST and stroke.Of the 4717 ACS patients who underwent PCI and stenting, 83% received clopidogrel and 17% newer P2Y12 inhibitors. The rate of EST was similar in both groups (1.7% in the newer P2Y12 inhibitor group vs. 1.4% in the clopidogrel-treated patients, p = 0.42). Results were consistent after multivariate analysis (adjusted HR = 1.06 [p = 0.89]). MACE occurred in 6.4% in the newer P2Y12 inhibitor group compared with 9.2% in the clopidogrel group (P<0.01). However, multivariate logistic regression modeling showed that treatment with newer P2Y12 inhibitors was not significantly associated with the secondary endpoint of MACE when compared with clopidogrel therapy [OR = 1.26 95%CI (0.93–1.73), P = 0.136]. The incidence of "real life" EST at 1month is relatively low, and appears to be similar in patients who receive newer P2Y12 inhibitors as well as in those who receive clopidogrel. PMID:27310147
Asher, Elad; Abu-Much, Arsalan; Goldenberg, Ilan; Segev, Amit; Sabbag, Avi; Mazin, Israel; Shlezinger, Meital; Atar, Shaul; Zahger, Doron; Polak, Arthur; Beigel, Roy; Matetzky, Shlomi
2016-01-01
Early stent thrombosis (EST) (≤ 30 days after stent implantation) is a relatively rare but deleterious complication of percutaneous coronary intervention (PCI). Administration of newer P2Y12 inhibitors (prasugrel and ticagrelor) combined with aspirin has been shown to reduce the incidence of sub-acute and late stent thrombosis, compared with clopidogrel. We investigated the "real life" incidence of EST in patients from a large acute coronary syndrome (ACS) national registry, where newer P2Y12 inhibitors are widely used. Patients were derived from the ACS Israeli Survey (ACSIS), conducted during 2006, 2008, 2010 and 2013. Major adverse cardiac events (MACE) at 30days were defined as all-cause death, recurrent ACS, EST and stroke.Of the 4717 ACS patients who underwent PCI and stenting, 83% received clopidogrel and 17% newer P2Y12 inhibitors. The rate of EST was similar in both groups (1.7% in the newer P2Y12 inhibitor group vs. 1.4% in the clopidogrel-treated patients, p = 0.42). Results were consistent after multivariate analysis (adjusted HR = 1.06 [p = 0.89]). MACE occurred in 6.4% in the newer P2Y12 inhibitor group compared with 9.2% in the clopidogrel group (P<0.01). However, multivariate logistic regression modeling showed that treatment with newer P2Y12 inhibitors was not significantly associated with the secondary endpoint of MACE when compared with clopidogrel therapy [OR = 1.26 95%CI (0.93-1.73), P = 0.136]. The incidence of "real life" EST at 1month is relatively low, and appears to be similar in patients who receive newer P2Y12 inhibitors as well as in those who receive clopidogrel.
Manchester iStent study: early results from a prospective UK case series.
Patel, Ilesh; de Klerk, Timothy A; Au, Leon
2013-01-01
To evaluate the 6-month efficacy and safety of the iStent microtrabecular bypass stent in patients with open-angle glaucoma. A prospective, uncontrolled, interventional case series. Forty-four eyes with open-angle glaucoma were reported. All subjects underwent ab interno implantation of a single iStent together with (n = 40) or without (n = 4) cataract surgery. Patients were assessed at postoperative week 1, months 1 and 3, and quarterly, thereafter. Data collected included visual acuity, intraocular pressure measurement using Goldmann tonometry, number of glaucoma medications, and number and type of complications. The mean age of the sample was 76.8 years. The mean duration since glaucoma diagnosis was 5.3 years (standard deviation 2.9 years). The mean visual acuity was 0.53 logMAR at baseline that improved to 0.23 at 6 months postoperatively. The mean baseline intraocular pressure was 21.1 mmHg, and this decreased significantly to 16.7 mmHg at 6 months (P < 0.01). The mean number of drops prescribed preoperatively was 2.3, which decreased to 0.6 at 6 months (P < 0.01). Sixty-six per cent of patients were drop-free at 6 months. One patient developed an hyphaema following surgery; no other adverse events were recorded. The iStent proved to be a safe and effective treatment for patients with open-angle glaucoma over our 6-month follow up period. Insertion resulted in a significant decrease in intraocular pressure as well as the number of topical antiglaucoma medications required for adequate intraocular pressure control. © 2013 The Authors. Clinical and Experimental Ophthalmology © 2013 Royal Australian and New Zealand College of Ophthalmologists.
New dedicated bifurcated silicone stent placement for stenosis around the primary right carina.
Oki, Masahide; Saka, Hideo
2013-08-01
Silicone stenting has been widely used to palliate respiratory symptoms in patients suffering from airway stenosis. Although many types and shapes of stents have been developed, there is no ideal stent for stenosis around the carina between the bronchus to the right upper lobe and the bronchus intermedius (primary right carina). The purpose of this study was to evaluate the feasibility, efficacy, and safety of a new silicone stent designed for treating airway stenosis around the primary right carina. We recruited 16 patients with suspected stenosis around the primary right carina. Ten of the patients met the inclusion criteria for inserting the study stent. All stenting procedures were performed with a rigid and flexible bronchoscope under general anesthesia. The study stent could be mounted successfully on the primary right carina in all 10 patients. Five patients underwent stenting using only the new stent, and the other five underwent stenting with it on the primary right carina and a silicone Y stent on the main carina. The dyspnea index improved in eight of the 10 patients, including one who was mechanically ventilated. Early complications developed in three patients (temporary pneumonia in two and retention of secretions in one), and late complications occurred in two patients (granuloma formation in one and hemoptysis in one). Stent placement with the new silicone stent designed to fit on the primary right carina is feasible, effective, and acceptably safe. UMIN-Clinical Trials Registry; No.: UMIN000001776; URL: www.umin.ac.jp/ctr.
Stent Implantation for Superior Vena Cava Syndrome of Malignant Cause.
Büstgens, Felix A; Loose, Reinhard; Ficker, Joachim H; Wucherer, Michael; Uder, Michael; Adamus, Ralf
2017-05-01
Purpose The purpose of this paper is the retrospective analysis of endovascular therapy for the treatment of superior vena cava syndrome (SVCS) of malignant cause. This study focuses on the effectiveness of the therapy regarding the duration of remission, symptom control and practicability. Materials and Methods From January 2003 to November 2012, therapeutic implantation of one or more stents was performed in 141 patients suffering from SVCS. The medical history was retrospectively researched using digitalized patient files. If those were incomplete, secondary research was conducted using the cancer registry of the General Hospital Nuremberg, the cancer registry of the tumor center at Friedrich-Alexander-University Erlangen-Nuremberg (FAU) or information given by physicians in private practice. This data was collected using Microsoft Office Excel ® and statistically analyzed using IBM SPSS Statistics 22 ® . Results 168 stents were implanted in 141 patients (median age: 64.6 years; range: 36 - 84), 86 being male and 55 being female. In 121 patients, SVCS was caused by lung cancer (85.8 %), in 9 patients by mediastinal metastasis of an extrathoracic carcinoma (6.4 %), in 3 patients by mesothelioma of the pleura (2.1 %) and in 1 patient by Hodgkin's disease (0.7 %). There was no histological diagnosis in 7 cases (4.9 %). The primary intervention was successful in 138 patients (97.9 %). Immediate thrombosis in the stent occurred in the remaining 3 cases. Recurrence of SVCS was observed in 22 patients (15.6 %), including 5 early and 17 late occlusions. Stent dislocation or breakage was not observed. As expected, the survival after implantation was poor. The median survival was 101 days, and the median occlusion-free survival was 80 days. Conclusion The symptomatic therapy of SVCS with endovascular stents is effective and safe. Despite effective symptom control and a low rate of recurrence, the patients' prognosis is poor. Key Points: · Patients with SVCS of malignant cause have a poor prognosis.. · Lung cancer is the most common cause for SVCS.. · Endovascular therapy is safe and effective.. Citation Format · Büstgens FA, Loose R, Ficker JH et al. Stent Implantation for Superior Vena Cava Syndrome of Malignant Cause. Fortschr Röntgenstr 2017; 189: 423 - 430. © Georg Thieme Verlag KG Stuttgart · New York.
Ductal recanalization and stenting for late presenters with TGA intact ventricular septum
Kothari, Shyam S; Ramakrishnan, Sivasubramanian; Senguttuvan, Nagendra Boopathy; Gupta, Saurabh Kumar; Bisoi, Akshay K
2011-01-01
Introduction: The ideal management strategy for patients presenting late with transposition of great arteries (TGA), intact ventricular septum (IVS), and regressed left ventricle (LV) is not clear. Primary switch, two-stage switch, and Senning operation are the options. Left ventricular retraining prior to arterial switch by ductal stenting may be effective, but the experience is very limited. Methods: Five of six children aged 3–6 months with TGA-IVS and regressed LV underwent recanalization and transcatheter stenting of ductus arteriosus. The ductal stent was removed during arterial switch surgery. Results: The procedure was successful in 5/6 patients. All the patients had totally occluded ductus and needed recanalization with coronary total occlusion hardware. The ductus was dilated and stented with coronary stents. In all the patients, there was significant luminal narrowing despite adequate stent placement and deployment. Two patients needed reintervention for abrupt closure of the stent. Ductal stenting resulted in left ventricular preparedness within 7–14 days. One patient died of progressive sepsis after 14 days of stenting, even though the LV was prepared. Four patients underwent successful uneventful arterial switch surgery. During surgery, it was observed that the mucosal folds of duct were protruding through the struts of the stent in one patient. Conclusions: Ductal stenting is a good alternative strategy for left ventricular retraining in TGA with regressed LV even in patients with occluded ducts. PMID:21976872
Chen, Hong-Lin; Shen, Wang-Qin; Liu, Kun
2017-05-01
Stent insertion is a feasible and safe palliative management for advanced unresectable esophageal cancer. The aim of this study is to assess the efficacy of radioactive stent for unresectable esophageal cancer compared with conventional stent. Systematic searches of the PubMed and Web of science are dated from their beginning to January 25, 2016. Studies that compared radioactive stent with conventional stent for unresectable esophageal cancer were included. The outcomes were postimplantation survival, relief of dysphagia, and complications related to stent implant. Six studies with 539 patients were included. All of them used stent equipped with radioactive iodine beads as a radioactive stent. The pooled weighted mean difference for median survival was 2.734 months (95% CI 1.710-3.775; Z = 5.21, P = 0.000) between two groups. The 1,3,6 month survival rates were higher in radioactive stents than conventional stent, with the pooled ORs 3.216 (95% CI 1.293-7.999; Z = 2.51, P = 0.012), 3.095 (95% CI 1.908-5.020; Z = 4.58, P = 0.000), and 7.503 (95% CI 2.206- 25.516; Z = 3.23, P = 0.001, respectively). The pooled hazard ratio was 0.464 (95% CI 0.328-0.655; Z = 4.35, P = 0.000) between two groups. For relief of dysphagia, two stents all have good relief of the dysphagia effect, but radioactive stent showed a better effect at 3, 6 months follow-up after implantation. For complications related to stent implant, no significant differences were found between two stents in terms of severe chest pain (30.0% vs. 35.7%, OR 0.765, 95% CI 0.490-1.196), gastroesophageal reflux (18.6% vs. 16.1%, OR 1.188, 95% CI 0.453-3.115), fever (12.1% vs. 12.1%, OR 1.014, 95% CI 0.332-3.097), bleeding (16.7% vs. 14.2%, OR 1.201, 95% CI 0.645-2.236), perforation or fistula (6.1% vs. 9.0%, OR 0.658, 95% CI 0.291-1.486), pneumonia (10.7% vs. 14.1%, OR 0.724, 95% CI 0.343-1.526), stent migration (7.0% vs. 10.2%, OR 0.651, 95% CI 0.220-1.924), and restenosis (24.2% vs. 20.6%, OR 1.228, 95% CI 0.674-2.239). Radioactive stent insertion had potential benefits for palliative management for patients with unresectable esophageal cancer. This method prolonged survival and dysphagia relief period without more complications. However, this conclusion should be confirmed by more trials. © International Society for Diseases of the Esophagus 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Wang, Juan; Smith, Christopher E.; Sankar, Jagannathan; Yun, Yeoheung; Huang, Nan
2015-01-01
Absorbable metals have been widely tested in various in vitro settings using cells to evaluate their possible suitability as an implant material. However, there exists a gap between in vivo and in vitro test results for absorbable materials. A lot of traditional in vitro assessments for permanent materials are no longer applicable to absorbable metallic implants. A key step is to identify and test the relevant microenvironment and parameters in test systems, which should be adapted according to the specific application. New test methods are necessary to reduce the difference between in vivo and in vitro test results and provide more accurate information to better understand absorbable metallic implants. In this investigative review, we strive to summarize the latest test methods for characterizing absorbable magnesium-based stent for bioabsorption/biodegradation behavior in the mimicking vascular environments. Also, this article comprehensively discusses the direction of test standardization for absorbable stents to paint a more accurate picture of the in vivo condition around implants to determine the most important parameters and their dynamic interactions. PMID:26816631
Tellez, Armando; Seifert, Paul S; Donskoy, Elina; Sushkova, Natalia; Pennington, Douglas E; Milewski, Krzysztof; Krueger, Christian G; Kaluza, Greg L; Eppihimer, Michael J; Huibregtse, Barbara A; Dawkins, Keith D; Granada, Juan F
2014-05-01
The utility of animal models for the prediction of drug-eluting stent (DES) efficacy in human clinical trials is still unclear. The familial hypercholesterolemic swine (FHS) model has been shown to induce a human-like neointimal response to bare metal stent (BMS) implantation. However, its utility to discriminate efficacy signals following DES implantation is unknown. In this study, we aimed to test the efficacy and healing response of several everolimus-eluting stent (EES) platforms in the coronary territory of the FHS. A total of 19 EES platforms (SYNERGY=6, SYNERGY½-dose=7, and PROMUS Element=6) and an identical BMS control (Element=6) were implanted into the coronary arteries of nine FHS. All implants were performed under intravascular ultrasound guidance using a 1.2 : 1 overstretch ratio. At 30 days, the vascular response to the implant was evaluated by quantitative coronary angiography, optical coherence tomography, and histology. At 28 days, all EES platforms showed a significant decrease in angiographic late lumen loss (between 27 and 37%) compared with the BMS control group. This finding was confirmed both by optical coherence tomography (mean neointimal thickness=28-42% reduction) and by histology (mean neointimal thickness=44-55% reduction). All EES platforms showed similar degrees of neointimal inhibition. The presence of moderate to severe para-strut inflammation was observed in 83% of the stent sections in the BMS group compared with 28.6% in the SYNERGY½-dose group and 0% in the SYNERGY and PROMUS groups (P=0.0002). There was a 68-95% reduction in MMP9 expression in the media in all EES platforms compared with the BMS controls. The presence of mild to moderate para-strut fibrin deposits ranged from 66.7 to 83.4% in all EES platforms compared with 16.7% in the EBMS group. The FHS coronary injury model showed the efficacy of several EES platforms compared with an identical BMS control. Everolimus eluted from different polymeric platforms showed lower levels of inflammation and slightly higher fibrin deposits compared with BMS controls.
Lee, Tae Hoon; Park, Do Hyun; Lee, Sang Soo; Choi, Hyun Jong; Lee, Jun Kyu; Kim, Tae Hyeon; Kim, Jong Hyeok; Jeong, Seok; Park, Sang-Heum; Moon, Jong Ho
2013-02-01
Theoretically, the side-by-side bilateral placement of metal stents may be technically easier than stent-in-stent bilateral placement in stent revision. However, side-by-side placement can be technically challenging, as the deployment of the first stent can preclude the passage of the second stent. We explored the technical feasibility and revision efficacy of endoscopic bilateral side-by-side stent placement for malignant hilar biliary strictures. Forty-four patients with Bismuth type II or higher malignant hilar biliary strictures were enrolled in seven academic tertiary referral centers. Endoscopic placement of side-by-side bilateral metal stents with 7F thin delivery shaft was performed. The outcome measurements were the technical and functional success, adverse events, endoscopic revision success rate, and stent patency. Overall, the technical and functional success rates were 91 % (40/44), and 98 % (39/40), respectively. Two of the failed patients were converted successfully with subsequent contralateral stent-in-stent placement, and the other patients underwent percutaneous intervention. Early stent-related adverse events occurred in 10 %. The endoscopic revision rate due to stent malfunction during follow-up (median: 180 days) was 45 % (18/40; tumor ingrowth in 4 and in-stent sludge impaction/stone formation in 14 patients). The endoscopic revision success rate was 92 % (12/13). Five patients with comorbidity underwent initial percutaneous intervention. The median survival and stent patency periods were 180 and 157 days, respectively. The sequential placement of a metal stent with a 7F thin delivery shaft in bilateral side-by-side procedures may be feasible and effective for malignant hilar biliary strictures and for endoscopic stent revision.
Long-Term Outcomes of Stenting the Proximal Left Anterior Descending Artery in the PROTECT Trial.
Roguin, Ariel; Camenzind, Edoardo; Kerner, Arthur; Beyar, Rafael; Boersma, Eric; Mauri, Laura; Steg, Ph Gabriel; Wijns, William
2017-03-27
This study sought to compare the outcomes of patients undergoing drug-eluting stent implantation according to lesion location within or outside the proximal left anterior descending (LAD) artery. Proximal LAD artery involvement is considered uniquely in revascularization guidelines. The impact of LAD lesion location on long-term outcomes after revascularization is poorly understood in context of current percutaneous coronary intervention and medical therapy. Among 8,709 patients enrolled in PROTECT (Patient Related Outcomes with Endeavor Versus Cypher Stenting Trial), a multicenter percutaneous coronary intervention trial, we compared the outcomes of 2,534 patients (29.1%) (3,871 lesions [31.5%]) with stents implanted in the proximal LAD to 6,172 patients (70.9%) (8,419 lesions [68.5%]) with stents implanted outside the proximal LAD. At the 4-year follow-up, death rates were the same (5.8% vs. 5.8%; p > 0.999), but more myocardial infarctions occurred in the proximal LAD group (6.2% vs. 4.9%; p = 0.015). The rate of clinically driven target vessel failure (TVF) (14.8% vs. 13.5%; p = 0.109), major adverse cardiac event(s) (MACE) (15.0% vs. 13.7%; hazard ratio: 1.1; 95% confidence interval: 0.97 to 1.31; p = 0.139), and stent thrombosis (2.1% vs. 2.0%; p = 0.800) were similar. Drug-eluting stent type had no interaction with MACE or TVF. In multivariate analysis, the proximal LAD was a predictor of myocardial infarction (p = 0.038) but not of TVF (p = 0.149) or MACE (p = 0.069). In this study of contemporary percutaneous coronary intervention, proximal LAD location was associated with higher rates of myocardial infarction during the long-term follow-up, but there were no differences in stent thrombosis, death, TVF, or overall MACE. This finding may suggest that, in the drug-eluting stent era, proximal LAD no longer confers a different prognosis than other lesion sites. (Randomized Study Comparing Endeavor With Cypher Stents [PROTECT]; NCT00476957). Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Usefulness of Corsair microcatheter to cross stent struts in bifurcation lesions.
Fujimoto, Yoshihide; Iwata, Yo; Yamamoto, Masashi; Kobayashi, Yoshio
2014-01-01
Side branch compromise after stenting in bifurcation lesions is a matter of concern. It may happen that even low-profile balloon catheters do not cross stent struts after rewiring. The Corsair catheter is a hybrid catheter that has features of a microcatheter and a support catheter. The present study evaluated usefulness of the Corsair catheter to facilitate advancing a low-profile balloon catheter through stent struts in bifurcation lesions. After rewiring, low-profile balloon catheters failed to cross stent struts of 29 bifurcation lesions. The Corsair microcatheter successfully crossed stent struts in all lesions except one (97 %) where a stent was implanted to treat in-stent restenosis (stent-in-stent). Low-profile balloon catheters were able to advance into the side branch of all bifurcation lesions where the Corsair microcatheter crossed stent struts. In conclusion, the Corsair microcatheter may be utilized if low-profile balloon catheters are unable to cross stent struts in bifurcation lesions.
Vasilikostas, Georgios; Sanmugalingam, Nimalan; Khan, Omar; Reddy, Marcus; Groves, Chris; Wan, Andrew
2014-03-01
Endoscopic stenting is a relatively new technique for the treatment of post sleeve gastrectomy complications. Partially covered stents are used in this method to minimise the risk of migration but they are associated with difficulties with removal. Patients requiring emergency stenting following sleeve gastrectomy underwent insertion of a partially covered metallic stent. One month later, if the stent was not easily removable, a fully covered overlapping stent was inserted and the patient was readmitted 2 weeks later for removal of both stents. Four patients required stenting following sleeve gastrectomy leaks, and one patient required stenting for a stricture. In these cases, a 'stent in a stent' technique was used for removal. This technique allows the safe removal of partially covered stents inserted following sleeve gastrectomy complications.
Medical implants and methods of making medical implants
Shaw, Wendy J; Yonker, Clement R; Fulton, John L; Tarasevich, Barbara J; McClain, James B; Taylor, Doug
2014-09-16
A medical implant device having a substrate with an oxidized surface and a silane derivative coating covalently bonded to the oxidized surface. A bioactive agent is covalently bonded to the silane derivative coating. An implantable stent device including a stent core having an oxidized surface with a layer of silane derivative covalently bonded thereto. A spacer layer comprising polyethylene glycol (PEG) is covalently bonded to the layer of silane derivative and a protein is covalently bonded to the PEG. A method of making a medical implant device including providing a substrate having a surface, oxidizing the surface and reacting with derivitized silane to form a silane coating covalently bonded to the surface. A bioactive agent is then covalently bonded to the silane coating. In particular instances, an additional coating of bio-absorbable polymer and/or pharmaceutical agent is deposited over the bioactive agent.
Tsai, Ying-Nan; Wang, Hsiu-Po; Huang, Chih-Kun; Chang, Po-Chin; Lin, I-Chang; Tai, Chi-Ming
2018-01-01
Postoperative leak is a serious complication of bariatric surgery and often results in significant morbidity and mortality. Stent placement is a less invasive alternative to surgery for the treatment of bariatric surgical leak. We evaluated the efficacy and complications of covered self-expandable metal stents (SEMS) in the treatment of post-bariatric surgical leak. We retrospectively reviewed patients who underwent stent placement for leak after bariatric surgery. Leak was diagnosed by upper gastrointestinal series or was visualized during the endoscopy. We examined the timing of stent placement, size of the leak, stent migration and its complications, total stent treatment duration, and treatment outcome. Between January 2011 and April 2015, seven patients underwent covered SEMS placement for leak after bariatric surgery, including laparoscopic sleeve gastrectomy (LSG) (n = 5) and laparoscopic loop duodenojejunal bypass with sleeve gastrectomy (LDJB-SG) (n = 2). A stent was placed in one patient for infection control and bridging to revisional surgery. Among the other six patients, one patient who received stent placement one year after leak diagnosis failed to achieve leak closure, and five patients with early stent placement achieved leak closure. Three patients with small leak achieved leak closure more quickly. Stent migration was found in six patients, and associated ulcers occurred in five patients. We conclude that stenting is effective in the management of staple-line leaks following LSG and LDJB-SG. Stent migration and associated ulcers are common after stent placement. Early stent removal can be achieved in patients with small leaks. Copyright © 2017. Published by Elsevier Taiwan.
The burden of chronic ureteral stenting in cervical cancer survivors
Fan, Yunhua; Jarosek, Stephanie; Elliott, Sean P.
2017-01-01
ABSTRACT Purpose Ureteral obstruction in cervical cancer occurs in up to 11% of patients, many of whom undergo ureteral stenting. Our aim was to describe the patient burden of chronic ureteral stenting in a population-based cohort by detailing two objectives: (1) the frequency of repeat procedures for ureteral obstruction; and, (2) the frequency of urinary adverse effects (UAEs) (e.g., lower urinary tract symptoms, flank pain). Materials and Methods From SEER-Medicare, we identified 202 women who underwent ureteral stent placement prior to or following cervical cancer treatment. The frequency of repeat procedures and rate ratios were compared between treatment modalities. The rates and rate ratios of UAEs were compared between our primary cohort (stent + cervical cancer) and the following groups: no stent + cervical cancer, stent + no cancer, and no stent + no cancer. The “no cancer” group was drawn from the 5% Medicare sample. Results 117/202 women (58%) underwent >1 stent procedure. The frequency of additional procedures was significantly higher in patients who received radiation as part of their treatment. UAEs were very common in women with stent + cancer. The rate of UTI was 190 (per 100 person-years), 67 for LUTS, 42 for stones, and 6 for flank pain. These rates were 3-10 fold higher than in the no stent + no cancer control group; rates were also higher than in the no stent + cancer and the stent + no cancer women. Conclusions The burden of disease associated with ureteral stents is higher than expected and urologists should be actively involved in stent management, screening for associated symptoms and offering definitive reconstruction when appropriate. PMID:27649113
Temporary use of silicone stents for severe airway stenosis in untreated malignant lymphoma.
Oki, Masahide; Saka, Hideo
2013-01-01
Airway stenting has become a popular method for palliation of airway stenosis; however, little has been reported about their use for patients with malignant lymphoma that occasionally causes a life-threatening condition. The aim of the study was to evaluate the efficacy and safety of airway stenting in chemoradiotherapy naive patients with severe airway stenosis due to malignant lymphoma. Patients who underwent airway stent placement from April 2007 to July 2011 in a single center were retrospectively reviewed. All stenting procedures were performed using rigid and flexible bronchoscopes under general anesthesia. We performed 174 airway stenting procedures (silicone stents in 154 procedures and metallic in 20 procedures) for 150 patients during the study period. Of the patients, 7 had untreated malignant lymphomas (4 diffuse large B-cell lymphomas, 2 lymphoblastic lymphomas, 1 mucosa-associated lymphoid tissue lymphoma). All patients underwent stenting using the silicone Y-stent (6 on the main carina and 1 on the primary right carina). Dyspnea was relieved immediately in 6 of 7 patients including the mechanically ventilated patient. Stents could be removed in all patients (median 90 d after stenting; range, 32 to 245 d) because of the tumor response to tumor-specific therapy. One granuloma formation and 1 mucus retention triggered the decision to remove the stents. Airway stenting using silicone stents is safe and effective in palliation of airway stenosis in patients with untreated malignant lymphoma, and permits postprocedural tumor-specific therapy. The response to tumor-specific therapy can be expected, and so removable stents should be selected.
Treatment of Intra- and Extracranial Arterial Dissections Using Stents and Embolization
DOE Office of Scientific and Technical Information (OSTI.GOV)
Joo, Jin Yang; Ahn, Jung Yong, E-mail: jyahn@cha.ac.kr; Chung, Young Sun
2005-06-15
Purpose. To evaluate the safety and efficacy of stent placement for extracranial and intracranial arterial dissections. Methods. Eighteen patients underwent endovascular treatment of carotid and vertebral dissections using intraluminal stent placement. Five patients with arterial dissection were treated, 2 using one insertion of a single stent and 3 using placement of two stents. Patients with a dissecting aneurysm were treated as follows: 7 patients with insertion of one stent, 4 with placement of two stents, and 2 by stent-assisted Guglielmi detachable coil embolization. In the 18 patients in whom stenting was attempted, the overall success in reaching the target lesionmore » was 94.4%. Of the 17 patients treated with stents, stent release and positioning were considered optimal in 16 (94%) and suboptimal in one (6%). In patients who underwent a successful procedure, all parent arteries were preserved. There were no instances of postprocedural ischemic attacks, new neurologic deficits, or new minor or major strokes prior to patient discharge. In follow up, all patients were assessed, using the modified Rankin scale, as functionally improved or of stable clinical status. The reduction in dissection-induced stenosis or pseudoaneurysm, the patency rate obtained at follow-up, and the lack of strokes (ischemic or hemorrhagic) suggest that stent placement offers a viable alternative to complex surgical bypass or reconstructive procedures. The long-term efficacy and durability of stent placement for arterial dissection remain to be determined in a larger series.« less
Miranda, B; Pizzi, M N; Aguadé-Bruix, S; Domingo, E; Candell-Riera, J
2015-01-01
A 63-year-old male patient with a history of stent implantation in the left anterior descending three months before. Due to the presentation of vegetative symptoms, he was referred for gated-SPECT myocardial perfusion. During acquisition of the resting images he presented chest pain and ST segment elevation, so that urgent cardiac catheterization was performed, showing stent thrombosis. Rest perfusion imaging showed a defect in anterior and apical perfusion, more severe and extensive than in the stress images, with striking left ventricular dilatation and a fall in the ejection fraction related to the acute ischemia phenomenon. Intense exercise is associated with a transient activation of the coagulation system and hemodynamic changes that might induce thrombosis, especially in recently implanted coronary stents that probably still have not become completely endothelialized. Copyright © 2014 Elsevier España, S.L.U. y SEMNIM. All rights reserved.
Technological Advances in Stent Therapies: a Year in Review.
Raffoul, Jad; Nasir, Ammar; Klein, Andrew J P
2018-04-07
Stent technology has rapidly evolved since the first stainless steel bare metal stents with substantial developments in scaffolding, polymer, drug choice, drug delivery, and elution mechanisms. Most recently, there has been the evolution of bioabsorbable vascular scaffolds, potentially eliminating the need for long-term foreign object retention. These rapid developments have led to an ever-expanding selection of new stents, making the choice of which to use in which patient challenging. Operators must balance potential short- and long-term clinical ramifications, namely stent thrombosis, in-stent restenosis, target lesion revascularization, and target lesion failure. In this review, we hope to provide insight for interventional cardiologists on the details of stent technology and how this impacts outcomes, stent selection, and duration of dual-antiplatelet therapy duration post drug-eluting stent implantation.
Kang, Dong Oh; Seo, Hong Seog; Choi, Byung Geol; Lee, Eunmi; Kim, Ji Park; Lee, Sun Ki; Im, Sung Il; Na, Jin Oh; Choi, Cheol Ung; Lim, Hong Euy; Kim, Jin Won; Kim, Eung Ju; Rha, Seung-Woon; Park, Chang Gyu; Oh, Dong Joo
2015-01-20
Major adverse cardiovascular events (MACEs) in patients with or without cardiovascular disease (CVD) are greatly affected by various factors associated with metabolism and inflammation. To determine which clinical parameters at treatment are associated with the development of 2-year and 5-year MACEs in high-risk patients with CVD who have undergone drug-eluting stent (DES) implantation. The present study involved a total of 432 patients who underwent percutaneous coronary intervention with DES. Variables representing the average and absolute amount of change in clinical parameters over the 12-month follow-up were assessed for association with 2-year and 5-year development of MACE. The study population was divided into quartiles for the variable showing the highest correlation to MACE development. Estimated incidence of 2-year and 5-year MACEs for each of the quartiles was determined by survival curve analysis, and subgroup analysis was performed for patients with diabetes and statin users. Absolute change in fasting plasma glucose (FPG) over 12 months showed the highest correlation with 2-year and 5-year MACE development. The estimated incidence of MACE increased with increasing quartiles for absolute change in FPG. The association between absolute change in FPG and MACE development exhibited a stronger relationship for the specific subgroups of patients with diabetes and statin users. Increases and decreases in FPG had a comparable contribution to MACE development. A greater absolute change in FPG over 12 months post-PCI is an independent risk factor for 2-year and 5-year MACE development in DES-implanted patients, especially in the diabetes and statin users. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Experimental Evaluation of a New Tubular Coronary Stent (V-Flexª).
Shun; Wang; Zhou; Verbeken; Ping; Szilard; Yanming; Jianhua; De Scheerder IK
1998-11-01
The safety, efficacy, angiographic and histological effects of a new 316 L, SS seamless stainless steel tubular stent (V-Flexª, Global Therapeutics, Broomfield, Colorado) was evaluated in a porcine coronary and peripheral artery model. Implantation in the right coronary artery was successful in all 16 pigs. Eight pigs were angiographically controlled after 6 weeks and then sacrificed for morphometric analysis. All stented coronary vessels were widely patent at this moment and morphometric analysis showed only a mild fibromuscular neointimal hyperplasia resulting in a neointimal hyperplasia of 1.15 +/- 0.38 mm2. The remaining 8 pigs were controlled and sacrificed at 12 weeks. At that time, all stented vessels were patent and neointimal hyperplasia was 1.22 +/- 0.34 mm2. Comparison with the Palmaz-Schatzª coronary stent (Cordis, Miami, Florida) in a porcine peripheral artery model demonstrated significantly less neointimal hyperplasia at 6 weeks (1.11 +/- 0.73 vs. 2.40 +/- 0.36, p = 0.001) and at 12 weeks (1.53 +/- 0.42 vs. 2.47 +/- 0.63, p = 0.003) for the V-Flex stent. In conclusion, V-Flex coronary stent implantation in a porcine coronary and peripheral arteries results in a high procedural success rate without subacute thrombotic occlusions, despite no further anticoagulation nor antiplatelet therapy. Six and 12 week histopathological and morphometric evaluation demonstrated only a mild fibromuscular neointimal hyperplasia. Comparison with the Palmaz-Schatz coronary stent in a peripheral artery model showed significantly less neointimal hyperplasia in the V-Flex stent.
Benard, Nicolas; Coisne, Damien; Donal, Erwan; Perrault, Robert
2003-07-01
The stimulation of endothelial cells by arterial wall shear stress (WSS) plays a central role in restenosis. The fluid-structure interaction between stent wire and blood flow alters the WSS, particularly between stent struts. We have designed an in vitro model of struts of an intra-vascular prosthesis to study blood flow through a 'stented' section. The experimental artery consisted of a transparent square section test vein, which reproduced the strut design (100x magnifying power). A programmable pump was used to maintain a steady blood flow. Particle image velocimetry method was used to measure the flow between and over the stent branches, and to quantify WSS. Several prosthesis patterns that were representative of the total stent strut geometry were studied in a greater detail. We obtained WSS values of between -1.5 and 1.5Pa in a weak SS area which provided a source of endothelial stimulation propitious to restenosis. We also compared two similar patterns located in two different flow areas (one at the entry of the stent and one further downstream). We only detected a slight difference between the weakest SS levels at these two sites. As the endothelial proliferation is greatly influenced by the SS, knowledge of the SS modification induced by the stent implantation could be of importance for intra-vascular prostheses design optimisation and thus can help to reduce the restenosis incidence rate.
Schmidt, Arthur; Riecken, Bettina; Rische, Susanne; Klinger, Christoph; Jakobs, Ralf; Bechtler, Matthias; Kähler, Georg; Dormann, Arno; Caca, Karel
2015-05-01
Previous studies have shown superior patency rates for self-expandable metal stents (SEMS) compared with plastic stents in patients with malignant biliary obstruction. The aim of this study was to compare stent patency, patient survival, and complication rates between a newly designed, wing-shaped, plastic stent and SEMSs in patients with unresectable, malignant, distal, biliary obstruction. A randomized, multicenter trial was conducted at four tertiary care centers in Germany. A total of 37 patients underwent randomization between March 2010 and January 2013. Patients underwent endoscopic retrograde cholangiography with insertion of either a wing-shaped, plastic stent without lumen or an SEMS. Stent failure occurred in 10/16 patients (62.5 %) in the winged-stent group vs. 4/18 patients (22.2 %) in the SEMS group (P = 0.034). The median time to stent failure was 51 days (range 2 - 92 days) for the winged stent and 80 days (range 28 - 266 days) for the SEMS (P = 0.002). Early stent failure (< 8 weeks after placement) occurred in 8 patients (50 %) vs. 2 patients (11.1 %), respectively (P = 0.022). After obtaining the results from this interim analysis, the study was discontinued because of safety concerns. The frequency of stent failure was significantly higher in the winged-stent group compared with the SEMS group. A high incidence of early stent failure within 8 weeks was observed in the winged-stent group. Thus, the winged, plastic stent without central lumen may not be appropriate for mid or long term drainage of malignant biliary obstruction. Study registration ClinicalTrials.gov (NCT01063634). © Georg Thieme Verlag KG Stuttgart · New York.
GAN, ZHEN; JING, JIAN; ZHU, GUANGYU; QIN, YONGLIN; TENG, GAOJUN; GUO, JINHE
2015-01-01
The present study aimed to evaluate the effects of iodine-125 (125I) seeds on the proliferation of primary esophageal fibroblasts in dogs, and to assess the safety and preventive efficacy of 125I seed-pre-loaded esophageal stents in benign restenosis following implantation. Primary fibroblasts were cultured with various 125I seed activities, which were then evaluated using cell proliferation and apoptosis assays as well as cell cycle analysis using Annexin V/propidium iodide (PI) double staining and PI staining. Prior to sacrification, animals were submitted to esophageal radiography under digital subtraction angiography. Esophageal tissues were collected and examined for macroscopic, microscopic and pathological alterations. The results demonstrated a significant and dose-dependent inhibition of fibroblast proliferation and increased apoptosis following exposure to 125I seeds. G0/G1 fibroblast populations increased in a dose-dependent manner following treatment with 125I seeds, in contrast to cells in S phase. Four weeks following implantation, α-smooth muscle actin and proliferating cell nuclear antigen expression levels in the experimental group were significantly lower compared with those in the control group; in addition, eight weeks following implantation, esophageal inner diameters were increased in the experimental group. 125I seeds inhibited proliferation of dog esophageal fibroblasts via cell cycle arrest and apoptosis. In conclusion, 125I seed-pre-loaded esophageal stents inhibited benign hyperplasia in the upper edge of the stent to a certain extent, which relieved benign restenosis following implantation with a good safety profile. PMID:25543838
Pai, Madhava; Valek, Vlastimil; Tomas, Andrasina; Doros, Attila; Quaretti, Pietro; Golfieri, Rita; Mosconi, Cristina; Habib, Nagy
2014-02-01
The major complication occurring with biliary stents is stent occlusion, frequently seen because of tumour in-growth, epithelial hyperplasia, and sludge deposits, resulting in recurrent jaundice and cholangitis. We report a prospective study with the results of first in man percutaneous intraductal radiofrequency (RF) ablation to clear the blocked metal stents in patients with malignant biliary obstruction using a novel bipolar RF catheter. Nine patients with malignant biliary obstruction and blocked metal stents were included. These patients underwent intraductal biliary RF ablation through the blocked metal stent following external biliary decompression with an internal-external biliary drainage. All nine patients had their stent patency restored successfully without the use of secondary stents. Following this intervention, there was no 30-day mortality, haemorrhage, bile duct perforation, bile leak, or pancreatitis. Of the nine patients, six are alive and three patients are dead with a median follow-up of 122 (range 50-488) days and a median stent patency of 102.5 (range 50-321) days. Six patients had their stent patent at the time of last follow-up or death. Three patients with stent blockage at 321, 290, and 65 days postprocedure underwent percutaneous transhepatic drain insertion and repeat ablation. In this selective group of patients, it appears that this new approach is safe and feasible. Efficacy remains to be proven in future, randomized, prospective studies.
Silicone Y-Stent Placement on the Secondary Left Carina.
Oki, Masahide; Saka, Hideo
2015-01-01
The silicone Y-stent has mainly been used for the treatment of lesions around the main carina, and only a few case reports have been published on the technique for the lesions around the secondary left carina (LC2). We investigated the feasibility, efficacy and safety of a stenting technique using a silicone Y-stent for patients with airway stenosis around LC2. Patients who underwent airway stent placement between December 2010 and September 2014 in a single center were retrospectively reviewed. Under general anesthesia, using rigid and flexible bronchoscopes, the airway lumen was re-established followed by Y-stent placement on LC2. We performed 274 airway stenting procedures for 253 patients during the study period. Twelve of them (7 with lung cancer, 3 with esophageal cancer/carcinosarcoma, 1 with thyroid cancer and 1 with renal cancer) underwent a Y-stent placement on LC2. Respiratory symptoms were relieved in all patients. Six of 7 patients with supplemental oxygen, including the mechanically ventilated patient before stent placement, could be discharged without supplemental oxygen. The chest radiograph after the procedure showed increased lung volume in all 7 patients with partial or complete atelectasis. Median survival after stenting was 197 days at the time of data collection. Retention of secretions occurred in 1 and hemoptysis in another patient. Silicone Y-stent placement on LC2 is technically feasible, effective and acceptably safe. © 2015 S. Karger AG, Basel.
Li, Mingwu; Bai, Ming; Qi, Xingshun; Li, Kai; Yin, Zhanxin; Wang, Jianhong; Wu, Wenbing; Zhen, Luanluan; He, Chuangye; Fan, Daiming; Zhang, Zhuoli; Han, Guohong
2015-06-01
To investigate and compare the efficacy and safety of percutaneous transhepatic biliary stenting (PTBS) using a one- or two-stage procedure and determine the predictive factors for the efficacious treatment of malignant hilar obstruction (MHO). 159 consecutive patients with MHO who underwent PTBS were enrolled between January 2010 and June 2013. Patients were classified into one- or two-stage groups. Independent predictors of therapeutic success were evaluated using a logistic regression model. 108 patients were treated with one-stage PTBS and 51 patients were treated with two-stage PTBS. The stents were technically successful in all patients. Successful drainage was achieved in 114 patients (71.4 %). A total of 42 early major complications were observed. Re-interventions were attempted in 23 patients during follow-up. The cumulative primary patency rates at 3, 6, and 12 months were 88, 71, and 48 %, respectively. Stent placement using a one- or two-stage procedure did not significantly affect therapeutic success, early major complications, median stent patency, or survival. A stent placed across the duodenal papilla was an independent predictor of therapeutic success (odds ratio = 0.262, 95 % confidence interval [0.107-0.642]). Patients with stents across papilla had a lower rate of cholangitis compared with patients who had a stent above papilla (7.1 vs. 20.3 %, respectively, p = 0.03). The majority of patients with MHO who underwent one-stage PTBS showed similar efficacy and safety outcomes compared with those who underwent two-stage PTBS. Stent placement across the duodenal papilla was associated with a higher therapeutic success rate.
Wright, Andrew; Chang, Andrew; Bedi, Aarti Oza; Wamsteker, Erik-Jan; Elta, Grace; Kwon, Richard S; Carrott, Phillip; Elmunzer, B Joseph; Law, Ryan
2017-09-01
Esophageal fully covered self-expandable metal stents (FCSEMS) are indicated for the management of benign and malignant conditions of the esophagus including perforations, leaks, and strictures. FCSEMS are resistant to tissue ingrowth and are removable; however, stent migration occurs in 30-55% of cases. Endoscopic suture fixation of FCSEMS has been utilized to decrease the risk of stent migration though data supporting this practice remain limited. The primary aim of this study was to compare clinical outcomes and migration rate of patients who underwent placement of esophageal FCSEMS with and without endoscopic suture fixation. Our single-center, retrospective, cohort study includes patients who underwent esophageal FCSEMS placement with and without endoscopic suture fixation between January 1, 2012, and November 11, 2015. Baseline patient characteristics, procedural details, and clinical outcomes were abstracted. Logistic regression was performed to identify clinical and technical factors associated with outcomes and stent migration. A total of 51 patients underwent 62 FCSEMS placements, including 21 procedures with endoscopic suture fixation and 41 without. Suture fixation was associated with reduced risk of stent migration (OR 0.13, 95% CI 0.03-0.47). Prior stent migration was associated with significantly higher risk of subsequent migration (OR 6.4, 95% CI 1.6-26.0). Stent migration was associated with lower likelihood of clinical success (OR 0.21, 95% CI 0.06-0.69). There was a trend toward higher clinical success among patients undergoing suture fixation (85.7 vs. 60.9%, p = 0.07). Endoscopic suture fixation of FCSEMS was associated with a reduced stent migration rate. Appropriate patient selection for suture fixation of FCSEMS may lead to reduced migration in high-risk patients.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Mingwu, E-mail: lmw-jack@china.com.cn; Bai, Ming, E-mail: mingbai1983@gmail.com; Qi, Xingshun, E-mail: qixingshun19840717@126.com
AimTo investigate and compare the efficacy and safety of percutaneous transhepatic biliary stenting (PTBS) using a one- or two-stage procedure and determine the predictive factors for the efficacious treatment of malignant hilar obstruction (MHO).Methods159 consecutive patients with MHO who underwent PTBS were enrolled between January 2010 and June 2013. Patients were classified into one- or two-stage groups. Independent predictors of therapeutic success were evaluated using a logistic regression model.Results108 patients were treated with one-stage PTBS and 51 patients were treated with two-stage PTBS. The stents were technically successful in all patients. Successful drainage was achieved in 114 patients (71.4 %). Amore » total of 42 early major complications were observed. Re-interventions were attempted in 23 patients during follow-up. The cumulative primary patency rates at 3, 6, and 12 months were 88, 71, and 48 %, respectively. Stent placement using a one- or two-stage procedure did not significantly affect therapeutic success, early major complications, median stent patency, or survival. A stent placed across the duodenal papilla was an independent predictor of therapeutic success (odds ratio = 0.262, 95 % confidence interval [0.107–0.642]). Patients with stents across papilla had a lower rate of cholangitis compared with patients who had a stent above papilla (7.1 vs. 20.3 %, respectively, p = 0.03).ConclusionsThe majority of patients with MHO who underwent one-stage PTBS showed similar efficacy and safety outcomes compared with those who underwent two-stage PTBS. Stent placement across the duodenal papilla was associated with a higher therapeutic success rate.« less
In vitro and in vivo cell-capture strategies using cardiac stent technology - A review.
Ravindranath, Rohan R; Romaschin, Alexander; Thompson, Michael
2016-01-01
Stenosis is a symptom of coronary artery disease (CAD), and is caused by narrowing of arteries in the heart. Over the last several decades, medical implants such as cardiac stents have been developed to counter stenosis. Upon implantation of a stent to open up a restricted artery, narrowing of the artery can reoccur (restenosis), due to an immune response launched by the body towards the stent. Currently, restenosis is a major health concern for patients who have undergone heart surgery for coronary artery disease. Recently, there have been new methods developed to combat restenosis, which have shown potential signs of success. One proposed method is the use of stents to capture cells, thereby reducing immune response. This review will explore the different methods for cell capture both in vitro and in vivo. Biological modifications of the stent will be surveyed, as well as the use of surface science to immobilize biological probes. Immobilization of proteins and nucleotides, as well as use of magnetic field are all methods that will be further discussed. Finally, concluding remarks and future prospects will be presented. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Application of High Entropy Alloys in Stent Implants
NASA Astrophysics Data System (ADS)
Alagarsamy, Karthik
High entropy alloys (HEAs) are alloys with five or more principal elements. Due to these distinct concept of alloying, the HEA exhibits unique and superior properties. The outstanding properties of HEA includes higher strength/hardness, superior wear resistance, high temperature stability, higher fatigue life, good corrosion and oxidation resistance. Such characteristics of HEA has been significant interest leading to researches on these emerging field. Even though many works are done to understand the characteristic of these HEAs, very few works are made on how the HEAs can be applied for commercial uses. This work discusses the application of High entropy alloys in biomedical applications. The coronary heart disease, the leading cause of death in the United States kills more than 350,000 persons/year and it costs $108.9 billion for the nation each year in spite of significant advancements in medical care and public awareness. A cardiovascular disease affects heart or blood vessels (arteries, veins and capillaries) or both by blocking the blood flow. As a surgical interventions, stent implants are deployed to cure or ameliorate the disease. However, the high failure rate of stents has lead researchers to give special attention towards analyzing stent structure, materials and characteristics. Many works related to alternate material and/or design are carried out in recent time. This paper discusses the feasibility of CoCrFeNiMn and Al0.1CoCrFeNi HEAs in stent implant application. This work is based on the speculation that CoCrFeNiMn and Al0.1CoCrFeNi HEAs are biocompatible material. These HEAs are characterized to determine the microstructure and mechanical properties. Computational modeling and analysis were carried out on stent implant by applying CoCrFeNiMn and Al0.1CoCrFeNi HEAs as material to understand the structural behavior.
Natsuaki, Masahiro; Morimoto, Takeshi; Furukawa, Yutaka; Nakagawa, Yoshihisa; Kadota, Kazushige; Yamaji, Kyohei; Ando, Kenji; Shizuta, Satoshi; Shiomi, Hiroki; Tada, Tomohisa; Tazaki, Junichi; Kato, Yoshihiro; Hayano, Mamoru; Abe, Mitsuru; Tamura, Takashi; Shirotani, Manabu; Miki, Shinji; Matsuda, Mitsuo; Takahashi, Mamoru; Ishii, Katsuhisa; Tanaka, Masaru; Aoyama, Takeshi; Doi, Osamu; Hattori, Ryuichi; Kato, Masayuki; Suwa, Satoru; Takizawa, Akinori; Takatsu, Yoshiki; Shinoda, Eiji; Eizawa, Hiroshi; Takeda, Teruki; Lee, Jong-Dae; Inoko, Moriaki; Ogawa, Hisao; Hamasaki, Shuichi; Horie, Minoru; Nohara, Ryuji; Kambara, Hirofumi; Fujiwara, Hisayoshi; Mitsudo, Kazuaki; Nobuyoshi, Masakiyo; Kita, Toru; Kimura, Takeshi
2014-04-01
Late adverse events such as very late stent thrombosis (VLST) or late target-lesion revascularization (TLR) after first-generation sirolimus-eluting stents (SES) implantation have not been yet fully characterized at long term in comparison with those after bare-metal stent (BMS) implantation. Among 13 058 consecutive patients undergoing first percutaneous coronary intervention in the Coronary REvascularization Demonstrating Outcome study-Kyoto registry Cohort-2, 5078 patients were treated with SES only, and 5392 patients were treated with BMS only. During 7-year follow-up, VLST and late TLR beyond 1 year after SES implantation occurred constantly and without attenuation at 0.24% per year and at 2.0% per year, respectively. Cumulative 7-year incidence of VLST was significantly higher in the SES group than that in the BMS group (1.43% versus 0.68%, P<0.0001). However, there was no excess of all-cause death beyond 1 year in the SES group as compared with that in the BMS group (20.8% versus 19.6%, P=0.91). Cumulative incidences of late TLR (both overall and clinically driven) were also significantly higher in the SES group than in the BMS group (12.0% versus 4.1%, P<0.0001 and 8.5% versus 2.6%, P<0.0001, respectively), leading to late catch-up of the SES group to the BMS group regarding TLR through the entire 7-year follow-up (18.8% versus 25.2%, and 10.6% versus 10.2%, respectively). Clinical presentation as acute coronary syndrome was more common at the time of late SES TLR compared with early SES TLR (21.2% and 10.0%). Late catch-up phenomenon regarding stent thrombosis and TLR was significantly more pronounced with SES than that with BMS. This limitation should remain the target for improvements of DES technology.
Chiarelli, Tommaso; Franchini, Federico; Lamma, Achille; Lamma, Evelina; Sansoni, Tommaso
2012-03-01
Using oral implantology software and transferring the preoperative planning into a stereolithographic model, prosthodontists can produce the related surgical guide. This procedure has some disadvantages: bone-supported stent invasiveness, lack of references due to scattering and non-negligible stereolithography cost. An alternative solution is presented that provides an ideal surgical stent (not invasive, precise, and cheap) as a result. This work focuses on the third phase of a fully 3D approach to oral implant planning, that starts by CT scanning a patient who wears a markers-equipped radiological stent, continues exploiting built-on-purpose preoperative planning software, and finishes producing the ideal surgical template. A 5-axes bur-equipped robot has been designed able to reproduce the milling vectors planned by the software. Software-robot interfacing has been achieved properly matching the stent reference frame and the software and robot coordinate systems. Invasiveness has been avoided achieving the surgical stent from the mucosa-supported radiological mask wax-up. Scattering is ignored because of the surgical stent independency from the bone structure radiography. Production cost has been strongly reduced by avoiding the stereolithographic model. Finally, software-robot interfacing precision has been validated comparing digitally a multi-marker base and its planning transfer. Average position and orientation errors (respectively 0.283 mm ± 0.073 mm and 1.798° ± 0.496°) were significantly better than those achieved using methods based on stereolithography (respectively, 1.45 mm ± 1.42 mm and 7.25° ± 2.67°, with a general best maximum translation discrepancy of about 1.1 mm). This paper describes the last step of a fully 3D approach in which implant planning can be done in a 3D environment, and the correct position, orientation and depth of the planned implants are easily computed and transferred to the surgical phase. Copyright © 2011 John Wiley & Sons, Ltd.
de la Torre Hernández, José M; Oteo Domínguez, Juan F; Hernández, Felipe; García Camarero, Tamara; Abdul-Jawad Altisent, Omar; Rivero Crespo, Fernando; Cascón, José D; Zavala, Germán; Gimeno, Federico; Arrebola Moreno, Antonio L; Andraka, Leire; Gómez Menchero, Antonio; Bosa, Francisco; Carrillo, Xavier; Sánchez Recalde, Ángel; Alfonso, Fernando; Pérez de Prado, Armando; López Palop, Ramón; Sanchis, Juan; Diarte de Miguel, José A; Jiménez Navarro, Manuel; Muñoz, Luz; Ramírez Moreno, Antonio; Tizón Marcos, Helena
2015-10-01
The recommendation for dual antiplatelet therapy following drug-eluting stent implantation ranges from 6 months to 12 months or beyond. Recent trials have suggested the safety of a 6-month dual antiplatelet therapy regimen, yet certain caveats to these studies limit the applicability of this shorter duration dual antiplatelet therapy strategy in real world settings. A registry was constructed with consecutive recruitment of patients undergoing new-generation drug-eluting stent implantation and prescribed 6 months of dual antiplatelet therapy. Propensity score matching was undertaken with a historical cohort of patients treated with second-generation drug-eluting stents who received 12 months of dual antiplatelet therapy from the ESTROFA-2 registry. The sample size was calculated using a noninferiority basis and the primary endpoint was the combination of cardiac death, myocardial infarction, revascularization, or major bleeding at 12 months. The analysis included 1286 patients in each group, with no significant differences in baseline characteristics. The primary endpoint occurred in 5.0% and 6.6% in the 6-month and 12-month groups, respectively (P = .001 for noninferiority). The incidence of definite or probable stent thrombosis was 0.5% and 0.7% in the 6-month and 12-month groups, respectively (P = .4). Major bleeding events were lower in the 6-month group than in the 12-month group (0.8% vs 1.4%; P = .2) CONCLUSIONS: In selected patients in this large multicenter study, the safety and efficacy of a 6-month dual antiplatelet therapy regimen after implantation of new-generation drug-eluting stents appeared to be noninferior to those of a 12-month dual antiplatelet therapy regimen. Copyright © 2015 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.
Le, Trong Binh; Lee, Taeg Ki; Park, Keun-Myoung; Jeon, Yong Sun; Hong, Kee Chun; Cho, Soon Gu
2018-04-25
To investigate the incidence and potential causes of contralateral deep vein thrombosis (DVT) after common iliac vein (CIV) stent placement in patients with May-Thurner syndrome (MTS). Data of 111 patients (women: 73%) who had CIV stent implantation for symptomatic MTS at a single center were retrospectively analyzed. Mean patient age was 63.1 ± 15.2 years. Median follow-up was 36 months (range, 1-142 months). Stent location was determined by venogram and classified as extended to the inferior vena cava (IVC), covered the confluence, or confined to the iliac vein. Potential causes of contralateral DVT were presumed based on venographic findings. The relationship between stent location and contralateral DVT was analyzed. Ten patients (9%, men/women: 4/6) exhibited contralateral DVT at a median timing of 40 months (range, 6-98 months). Median age was 69 years (range, 42-85 years). Median follow-up was 73.5 months (range, 20-134 months). Potential causes were venous intimal hyperplasia (VIH) (n = 7), "jailing" (n = 2), and indeterminate (n = 1). All patients with VIH had previous CIV stents overextended to the IVC. Overextension of CIV stent was associated with contralateral DVT (P < .001). The primary patency rate of the contralateral CIV stent was 70% at 20 months. Contralateral DVT after CIV stent implantation has a relatively high incidence and often occurs late during follow-up. Overextension of the CIV stent to the IVC is associated with development of contralateral DVT, and VIH should be considered a potential cause. Copyright © 2018 SIR. Published by Elsevier Inc. All rights reserved.
Li, Xun; He, Zhaohui; Yuan, Jian; Zeng, Guohua; He, Yongzhong; Lei, Ming
2007-08-01
The management of complicated benign upper urinary tract occlusion is extremely challenging, especially in patients unable to undergo an open operative procedure. We report the long-term results of a permanent metallic stent for benign upper urinary tract occlusion. From October 1995 to December 1998, 13 patients (8 men and 5 women, with a mean age of 43 years) with benign upper tract occlusion have been treated by metallic stent implantation. All patients had a nephrostomy tube to relieve the obstruction and the average time of the nephrostomy tube stay was 27 months, ranging from 3 to 131 months. The average length of occlusion was 2.7 cm, ranging from 1 to 3.6 cm. Ultrasonography, urography, diuresis renography and urine culture were performed every 3 months after stent insertion. Ureteroscopy was done when needed. The mean follow-up was 92 months (12-132 months). Ureteral patency was achieved in six patients and assisted patency with a Double-J stent was achieved in three patients. In two patients the kidney had to be removed because of progressive malfunction and in two patients the metal stent had to be extracted with the Holmium: YAG laser, burning it down due to the uncontrollable pyonephrosis. In three patients the ipsilateral flank pain recurred. One of these patients experienced urine leakage due to the initial nephrostomy tract: a ureteroscopy revealed a complete hyperplastic urothelial response. Proximal stone formations were found in 2 patients and all were removed by percutaneous nephrolithotomy (PCNL). No stent migration or fragmentation was observed. The implantation of metal stent is a safe and effective treatment for benign upper urinary tract occlusion, and has satisfying long-term outcome in selected cases. A further investigation is needed for its impact on the urodynamics of upper urinary tract.
Kozlov, B N; Panfilov, D S; Saushkin, V V; Kuznetsov, M S; Nasrashvili, G G; Andriianova, A V; Shipulin, V M
Spinal ischaemia in patients after reconstruction of the thoracic aorta is referred to the category of the most severe postoperative complications, especially in hybrid interventions. The present study was aimed at assessing the risks for the development of spinal ischaemia in patients after implantation of the 'E-vita open plus' stent graft into the descending portion of the thoracic aorta during hybrid reconstruction. The 'E-vita open plus' hybrid stent graft (Jotec, Germany) was implanted to 18 patients presenting with various pathology of the thoracic aorta (dissection, aneurysms). All operations were carried out in the conditions of moderate hypothermia, circulatory arrest and antegrade perfusion of the brain through the brachiocephalic trunk. It was determined that the distal end of the stent graft was located at the level of Th7-Th12. In 12 (66.7%) cases the 'lower' edge of the stent graft was located at the level of thoracic vertebrae Th8-Th9. Before the operation the number of open pairs of intercostal arteries amounted to 10 [9, 11]. After the operation, the number of the open pairs of the segmental arteries amounted to 3 [1; 4], they were all in the lower thoracic portion; the above-located intercostal arteries were shut by the stent graft. In 17 (94.5%) cases in the early postoperative period there were no signs of spinal ischaemia. Only one (5.5%) patient was clinically diagnosed to have developed transient spinal ischaemia noted to disappear spontaneously within the first 24 hours. A conclusion was made that using the 'E-vita open plus' stent graft in the course of hybrid reconstruction of the thoracic aorta was accompanied by the minimal risk for spinal ischaemic complications. The level of the location of the distal edge of the stent graft is not the determining factor in the risks of spinal complications in of such similar operations.
Müller-Hülsbeck, Stefan; Frahm, Christian; Behm, Charlotte; Schäfer, Phillip Jobst; Bolte, Hendrik; Heller, Martin; Jahnke, Thomas
2005-07-01
To determine feasibility, safety, and midterm patency of a monorail balloon stent device for the treatment of renal artery stenosis (RAS). During a period of 30 months, 47 patients (with severe hypertension, n=45; renal insufficiency, n=20) with 50 cases of RAS and indications for stent implantation (calcified ostial lesion, n=41; insufficient percutaneous transluminal angioplasty, n=6; dissection, n=3) were enrolled into the prospective evaluation. After predilation, 59 stents (Rx-Herculink 4 mm, n=2; 5 mm, n=19; 6 mm, n=35; 7 mm, n=3) were implanted under manometer control with use of the long-sheath technique (5 F; 6 F for 7-mm stents) via a femoral (n=44) or transbrachial approach (n=6). Parameters of hypertension and renal insufficiency were determined before and after the procedure and for a maximum of 18 months. Restenosis rate was determined with color duplex ultrasonography. Renal artery stent placement (mean diameter, 5.7 mm; mean length, 16 mm) was technically successful in all cases (100%). Mean blood pressure and serum creatinine level decreased from 177/93 mm Hg to 145/78 mm Hg and from 1.8 mg/dL to 1.5 mg/dL, respectively. Within 48 hours after the implantation, acute occlusions occurred in two patients, supposedly triggered by cholesterol embolization. Primary and primary assisted patency rates were 87% and 92% at 6 months and 75% and 84% at 18 months. Renal artery stent placement with the rapid-exchange monorail system is a safe procedure with promising patency rates. In combination with the long-sheath technique, adequate control of stent deployment is guaranteed during the entire intervention. The low profile of the device facilitates the use of small sheaths (5 F) to minimize access-site complications.
Anton, Susanne; Stahlberg, Erik; Horn, Marco; Wiedner, Marcus; Kleemann, Markus; Barkhausen, Joerg; Goltz, Jan P
2018-04-01
To evaluate the safety and efficacy of a novel balloon-expandable stent-graft for endovascular treatment of visceral artery aneurysms (VAA). Between 9/2014 and 1/2017 seven patients (69±15 years) with true (N.=4) and false (N.=3) VAAs were treated by implantation of balloon-expandable stent-grafts (E-ventus®, Jotec, Hechingen, Germany) using a transfemoral (N.=2) or transbrachial (N.=5) vascular access. The stent-graft was placed without prior passing of the landing zone with a sheath. In 3 of 7 patients (42.9%) additional coil or plug embolization was performed to prevent retrograde VAA perfusion. Endpoints were technical success (defined as delivery and implantation of the stent-graft in the intended position with complete exclusion of the VAA), peri-procedural complications and patency. Mean diameters of true VAAs (splenic artery: N.=2, common hepatic artery: N.=1, celiac trunk: N.=1) were 26±9 and of false (common hepatic artery: N.=2, gastroduodenal artery: N.=1) 29±14 mm. False aneurysms presented as emergencies with active bleeding. Technical success was 100%. One peri-procedural complication was noted: pseudoaneurysm of the accessed brachial artery. After a mean follow-up of 187 days 6/7 stent-grafts (85.7%) were patent. One patient (fVAA) died two days after the emergency procedure owing to multi-organ failure which was assessed to be non-procedure-related. Another patient (fVAA) died 7 months from the procedure owing to cancer. Endovascular treatment of true and false visceral artery aneurysms by use of the E-ventus® stent-graft is safe and effective. Flexibility of the stent-graft and shaft allows for implantation without passing the lesion with a sheath, enabling treatment of distal as well as complex visceral lesions. Long-term results regarding patency in a larger patient cohort are needed to confirm these findings.
Holmvang, Lene; Kelbæk, Henning; Kaltoft, Anne; Thuesen, Leif; Lassen, Jens Flensted; Clemmensen, Peter; Kløvgaard, Lene; Engstrøm, Thomas; Bøtker, Hans E; Saunamäki, Kari; Krusell, Lars R; Jørgensen, Erik; Tilsted, Hans-Henrik; Christiansen, Evald H; Ravkilde, Jan; Køber, Lars; Kofoed, Klaus Fuglsang; Terkelsen, Christian J; Helqvist, Steffen
2013-06-01
This study sought to compare the long-term effects of drug-eluting stent (DES) compared with bare-metal stent (BMS) implantation in patients with ST-segment elevation myocardial infarction (STEMI) undergoing primary percutaneous coronary intervention. The randomized DEDICATION (Drug Elution and Distal Protection in Acute Myocardial Infarction) trial evaluated the outcome after DES compared with BMS implantation in patients with STEMI undergoing primary percutaneous coronary intervention. Patients with a high-grade stenosis/occlusion of a native coronary artery presenting with symptoms <12 h and ST-segment elevation were enrolled after giving informed consent. Patients were randomly assigned to receive a DES or a BMS in the infarct-related lesion. Patients were followed for at least 5 years, and clinical endpoints were evaluated from population registries and hospital charts. The main endpoint was the occurrence of the first major adverse cardiac event (MACE), defined as cardiac death, nonfatal recurrent myocardial infarction, and target lesion revascularization. Complete clinical status was available in 623 patients (99.5%) at 5 years follow-up. The combined MACE rate was insignificantly lower in the DES group (16.9% vs. 23%), mainly driven by a lower need of repeat revascularization (p = 0.07). Whereas the number of deaths from all causes tended to be higher in the DES group (16.3% vs. 12.1%, p = 0.17), cardiac mortality was significantly higher (7.7% vs. 3.2%, p = 0.02). The 5-year stent thrombosis rates were generally low and similar between the DES and the BMS groups. No cardiac deaths occurring within 1 month could be clearly ascribed to stent thrombosis, whereas stent thrombosis was involved in 78% of later-occurring deaths. The 5-year MACE rate was insignificantly different, but the cardiac mortality was higher after DES versus BMS implantation in patients with STEMI. Stent thrombosis was the main cause of late cardiac deaths. Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Chen, Yu; Xiong, Yan; Jiang, Wentao; Yan, Fei; Guo, Meng; Wang, Qingyuan; Fan, Yubo
2015-01-01
The changes of hemodynamics and drug concentration distribution caused by the implantation of drug eluting stents (DESs) in curved vessels have significant effects on In-Stent Restenosis. A 3D virtual stent with 90° curvature was modelled and the distribution of wall shear stress (WSS) and drug concentration in this model were numerically studied at Reynolds numbers of 200, 400, 600, 800. The results showed that (1) the intensity of secondary flow at the 45° cross-section was stronger than that at the 90° cross-section; (2) As the Reynolds number increases, the WSS decreases. When the Reynolds number reaches 600, the low-WSS region only accounts for 3% of the total area. (3) The effects of Reynolds number on drug concentration in the vascular wall decreases in proportionally and then the blood velocity increased 4 times, the drug concentration in the vascular wall decreased by about 30%. (4) The size of the high drug concentration region is inversely proportional to the Reynolds number. As the blood velocity increases, the drug concentration in the DES decreases, especially at the outer bend. It is beneficial for the patient to decrease vigorous activities and keep calm at the beginning of the stent implantation, because a substantial amount of the drug is released in the first two months of stent implantation, thus a calm status is conducive to drug release and absorption; Subsequently, appropriate exercise which increases the blood velocity is helpful in decreasing regions of low-WSS.
Osugi, Naohiro; Suzuki, Susumu; Ishii, Hideki; Yasuda, Yoshinari; Shibata, Yohei; Tatami, Yosuke; Ota, Tomoyuki; Kawamura, Yoshihiro; Okumura, Satoshi; Tanaka, Akihito; Inoue, Yosuke; Matsuo, Seiichi; Murohara, Toyoaki
2014-07-01
Albuminuria has traditionally been associated with an elevated risk of cardiovascular events. However, few studies have examined the potential relation between albuminuria and periprocedural risk in percutaneous coronary intervention (PCI). The aim of this study was to evaluate the impact of albuminuria on the incidence of periprocedural myocardial injury (PMI) in patients who underwent PCI. The study included 252 consecutive patients who underwent PCI. The incidence of PMI was significantly higher in patients with albuminuria than in those with normoalbuminuria (31.9% vs 43.3%, respectively, p = 0.014). Even after adjustment for confounders, the presence of albuminuria predicted PMI (odds ratio 2.07, 95% confidence interval 1.08 to 3.97, p = 0.029). Furthermore, patients with albuminuria and preserved estimated glomerular filtration rate had a 4.2-fold higher risk for PMI than did patients with normoalbuminuria and preserved estimated glomerular filtration rate. In conclusion, albuminuria was a strong predictor of PMI in patients who underwent PCI. Copyright © 2014 Elsevier Inc. All rights reserved.
Vallurupalli, Srikanth; Kasula, Srikanth; Kumar Agarwal, Shiv; Pothineni, Naga Venkata K; Abualsuod, Amjad; Hakeem, Abdul; Ahmed, Zubair; Uretsky, Barry F
2017-08-01
High-pressure inflation for coronary stent deployment is universally performed. However, the duration of inflation is variable and does not take into account differences in lesion compliance. We developed a standardized "pressure optimization protocol" (POP) using inflation pressure stability rather than an arbitrary inflation time or angiographic balloon appearance for stent deployment. Whether this approach improves long-term outcomes is unknown. 792 patients who underwent PCI using either rapid inflation/deflation (n = 376) or POP (n = 416) between January 2009 and March 2014 were included. Exclusion criteria included PCI for acute myocardial infarction, in-stent restenosis, chronic total occlusion, left main, and saphenous vein graft lesions. Primary endpoint was target vessel failure [TVF = combined end point of target vessel revascularization (TVR), myocardial infarction, and cardiac death]. Outcomes were analyzed in the entire cohort and in a propensity analysis. Stent implantation using POP with a median follow-up of 1317 days was associated with lower TVF compared with rapid inflation/deflation (10.1 vs. 17.8%, P < 0.0001). This difference was driven by a decrease in TVR (7 vs. 10.6%, P = 0.0016) and cardiac death (2.9 vs. 5.8%, P = 0.017) while there was no difference in myocardial infarction (1 vs. 1.9%, P = 0.19). In the Cox regression model, deployment using POP was the only independent predictor of reduced TVF (HR 0.43; 0.29-0.64; P < 0.0001). In the propensity analysis (330 patients per group) TVF remained lower with POP vs. rapid inflation/deflation (10 vs. 18%, P < 0.0001). Stent deployment using POP led to reduced TVF compared to rapid I/D. These results recommend this method to improve long-term outcomes. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
Kądziela, Jacek; Januszewicz, Andrzej; Prejbisz, Aleksander; Michałowska, Ilona; Januszewicz, Magdalena; Florczak, Elżbieta; Kalińczuk, Łukasz; Norwa-Otto, Bożena; Warchoł, Ewa; Witkowski, Adam
2013-01-01
The aim of our study was to determine a potential relationship between resting translesional pressures ratio (Pd/Pa ratio), renal fractional flow reserve (rFFR) and blood pressure response after renal artery stenting. Thirty five hypertensive patients (49% males, mean age 64 years) with at least 60% stenosis in angiography, underwent renal artery stenting. Translesional systolic pressure gradient (TSPG), Pd/Pa ratio (the ratio of mean distal to lesion and mean proximal pressures) and hyperemic rFFR - after intrarenal administration of papaverine - were measured before stent implantation. Ambulatory blood pressure measurements (ABPM) were recorded before the procedure and after 6 months. The ABPM results were presented as blood pressure changes in subgroups of patients with normal (≥ 0.9) vs. abnormal (< 0.9) Pd/Pa ratio and normal (≥ 0.8) vs. abnormal (< 0.8) rFFR. Median Pd/Pa ratio was 0.84 (interquartile range 0.79-0.91) and strongly correlated with TSPG (r = -0.89, p < 0.001), minimal lumen diameter (MLD; r = 0.53, p < 0.005) and diameter stenosis (DS; r = -0.51, p < 0.005). Median rFFR was 0.78 (0.72-0.82). Similarly, significant correlation between rFFR and TSPG (r = -0.86, p < 0.0001), as well as with MLD (r = 0.50, p < 0.005) and DS (r = -0.51, p < 0.005) was observed. Procedural success was obtained in all patients. Baseline Pd/Pa ratio and rFFR did not predict hypertension response after renal artery stenting. Median changes of 24-h systolic/diastolic blood pressure were comparable in patients with abnormal vs. normal Pd/Pa ratio (-4/-3 vs. 0/2 mm Hg; p = NS) and with abnormal vs. normal rFFR (-2/-1 vs. -2/-0.5 mm Hg, respectively). Physiological assessment of renal artery stenosis using Pd/Pa ratio and papaverine- induced renal fractional fl ow reserve did not predict hypertension response after renal artery stenting.
Généreux, Philippe; Lee, Arthur C; Kim, Christopher Y; Lee, Michael; Shlofmitz, Richard; Moses, Jeffrey W; Stone, Gregg W; Chambers, Jeff W
2015-06-15
Percutaneous coronary intervention of severely calcified lesions has historically been associated with major adverse cardiac event (MACE) rates as high as 30%. In the ORBIT II (Evaluate the Safety and Efficacy of OAS in Treating Severely Calcified Coronary Lesions) trial, treatment of de novo severely calcified lesions with the Diamondback 360° Coronary Orbital Atherectomy System (OAS) resulted in low rates of procedural and 30-day adverse ischemic events. The long-term results from this trial have not been reported. We sought to determine the 1-year outcomes after orbital atherectomy of severely calcified coronary lesions. ORBIT II was a single-arm trial enrolling 443 subjects at 49 US sites with severely calcified lesions usually excluded from randomized trials. OAS utilizes a centrifugal differential sanding mechanism of action for plaque modification prior to stent implantation. After OAS drug-eluting stents were implanted in 88.2% of the patients. The primary safety end point was 30-day MACE, the composite of cardiac death, myocardial infarction, or target vessel revascularization [TVR]. The present analysis reports the 1-year follow-up results from ORBIT II. One-year data were available in 433 of 443 patients (97.7%), with median follow-up time of 16.7 months. The 1-year MACE rate was 16.4%, including cardiac death (3.0%), myocardial infarction (9.7%), and target vessel revascularization (5.9%). The 1-year target lesion revascularization rate was 4.7%, and stent thrombosis occurred in 1 patient (0.2%). Independent predictors of 1-year MACE and target vessel revascularization were diameter stenosis at baseline and the use of bare-metal stents. In patients with severely calcified lesions who underwent percutaneous coronary intervention, the use of OAS was associated with low rates of 1-year adverse ischemic events compared with historical controls. This finding has important clinical implications for the selection of optimum treatment strategies for patients with severely calcified lesions. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.
Damera, Sheshagiri Rao; Barik, Ramachandra; Prasad, Akula Siva
2016-09-01
The angioplasty of chronic total aortoiliac occlusion using transfemoral is controversial. From March 2014 to December 2015, four consecutive patients (4 males; mean age 58.2±6.8 years; age of range 51-65 years) underwent angioplasty and stenting of TASC-D occlusion. In all the cases, we failed to cross from femoral approach. On switching over to left brachial access, angioplasty was done successfully in all. There was no procedural site complication or clinical evidence cerebral thromboembolism. Self-expandable stents were implanted in all with adequate pre and post dilation. Complete revascularisation was achieved in two cases and in other two cases, the angioplasty to the left aortoiliac carina was staged. Therefore, it is better to avoid femoral approach as initial step to cross chronic TASC 2007 type D (chronic total aortoiliac occlusion or called extensive aortoiliac disease) because of failure to cross retrogradely due to subintimal course of guide wire leading to retrograde aortic dissection. Copyright © 2016 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.
Li, Teng-Fei; Huang, Guo-Hao; Li, Zhen; Hao, Chang-Fu; Ren, Jian-Zhuang; Duan, Xu-Hua; Zhang, Kai; Chen, Chen; Han, Xin-Wei; Jiao, De-Chao; Zhang, Meng-Fan; Wang, Yan-Li
2015-05-01
To determine the safety and feasibility of percutaneous transhepatic cholangiography (PTC) and intraductal radiofrequency (RF) ablation combined with biliary stent placement for malignant biliary obstruction. Data from patients with unresectable malignant biliary obstruction who underwent PTC, intraductal RF ablation, and biliary stent placement (n = 12) or PTC and biliary stent placement only (control group; n = 14) were reviewed. Postoperative complications, jaundice remission, and stent patency were assessed. All procedures were successful. No severe complications (eg, biliary bleeding, perforation) occurred. Two experimental group patients developed cholangitis, which resolved with conservative treatment. The 1-week jaundice remission and 3-month stent patency rates were similar in both groups, but the 6-month stent patency rate was higher in the experimental group (P < .05). In the experimental group, one death occurred as a result of gastrointestinal hemorrhage (unrelated to stent placement) by 3 months, and there were two cases of recurrent jaundice by 6 months. The latter two patients underwent repeat PTC, ablation, and stent placement. In the control group, one death occurred as a result of hepatic failure caused by progressive jaundice at 3 months, and another death resulted from disseminated intravascular coagulation caused by jaundice recurrence at 138 days after stent placement. In addition, seven patients developed jaundice recurrence (50-151 d after stent placement). PTC and repeat stent placement were performed in these patients. Percutaneous transhepatic cholangiography and intraductal RF ablation combined with biliary stent placement for malignant biliary obstruction is safe and feasible and effectively prolongs stent patency time. Copyright © 2015 SIR. Published by Elsevier Inc. All rights reserved.
Mao, Xiao-Nan; Lu, Zai-Ming; Wen, Feng; Liang, Hong-Yuan; Guo, Qi-Yong
2017-01-01
Abstract This study explored the effect of the implant position of stents across the Vater's ampulla on treatment outcomes in patients with lower bile duct obstruction. In the retrospective study, 41 patients with malignant obstruction of the lower bile duct and obstructive jaundice received percutaneous transhepatic biliary placement of bare-metal stents. Basic demographic data on patients, such as sex, age, and primary diseases, and follow-up data, including postoperative complications and jaundice-free survival, were recorded. The follow-up data on patients with an involved ampulla, patients with an uninvolved ampulla, patients with a stent across the ampulla, and patients with a stent at a site other than the ampulla were compared. Furthermore, prognostic factors for jaundice- free survival were investigated using Cox proportional hazards regression analysis. Among the 41 patients, 38 patients experienced subsiding of jaundice, whereas 3 cases had unsuccessful stent patency. Whether or not the ampulla was involved did not influence the incidence rates of postoperative complications and the jaundice-free survival time. Notably, when stents were placed across the ampulla, the jaundice-free survival time was significantly longer than when stents were placed at sites other than across the ampulla (P < .05). Furthermore, placement of the stent across the ampulla or at other sites was an independent prognostic factor (hazard ratio = 0.154, 95% confidence interval 0.042–0.560, P = .005) for jaundice-free survival of patients. The current study revealed that the implant position of a stent across the ampulla resulted in maintenance of stent patency and prolongation of the jaundice-free survival time. PMID:29137005
A new intratracheal stent made from nitinol, an alloy with "shape memory effect".
Vinograd, I; Klin, B; Brosh, T; Weinberg, M; Flomenblit, Y; Nevo, Z
1994-05-01
Temporary or permanent tracheal splinting in pediatric patients may be indicated in tracheomalacia or bronchomalacia, repair of congenital tracheal stenosis, and after tracheal resection. This study presents the results of the development of a new intraluminal airway stent made from titanium alloy, a metal with "shape memory effect". At low temperatures (martensitic state) the titanium alloy stent can be fashioned into a specific shape; then when heated to a higher temperature (austenitic state) the stent alters its shape, only to regain its original shape when recooled to the lower temperature. The stent, connected to a small electric power supply, was introduced into 20 young rabbits with the use of a 2.5 cm rigid bronchoscope. After implantation in the martensitic state the stent was warmed to 40 degrees C, the austenitic state, by an electric current of 1.5 to 3 ampere for 1 to 2 seconds. After a period of 8 to 10 weeks the stent was removed (in its martensitic state) through the same-sized bronchoscope after being cooled with 3 to 4 ml of 80% alcohol solution at 6 degrees C. No signs of airway obstruction developed in any of the animals after implantation or extraction of the stent. The biomechanical properties of the trachea, as shown by strain measurements with the use of incremental forces, showed significant differences between the stented and unstented segments (p < 0.005). The titanium alloy intratracheal stent adequately fulfilled the requirements of a temporary intraluminal airway splint, and because of its unique feature of shape memory effect the stent could be inserted, fixed, and removed easily, even in very small airways.
Inatomi, Osamu; Bamba, Shigeki; Shioya, Makoto; Mochizuki, Yosuke; Ban, Hiromitsu; Tsujikawa, Tomoyuki; Saito, Yasuharu; Andoh, Akira; Fujiyama, Yoshihide
2013-02-14
Although endoscopic biliary stents have been accepted as part of palliative therapy for cases of malignant hilar obstruction, the optimal endoscopic management regime remains controversial. In this study, we evaluated the safety and efficacy of placing a threaded stent above the sphincter of Oddi (threaded inside plastic stents, threaded PS) and compared the results with those of other stent types. Patients with malignant hilar obstruction, including those requiring biliary drainage for stent occlusion, were selected. Patients received either one of the following endoscopic indwelling stents: threaded PS, conventional plastic stents (conventional PS), or metallic stents (MS). Duration of stent patency and the incident of complication were compared in these patients. Forty-two patients underwent placement of endoscopic indwelling stents (threaded PS = 12, conventional PS = 17, MS = 13). The median duration of threaded PS patency was significantly longer than that of conventional PS patency (142 vs. 32 days; P = 0.04, logrank test). The median duration of threaded PS and MS patency was not significantly different (142 vs. 150 days, P = 0.83). Stent migration did not occur in any group. Among patients who underwent threaded PS placement as a salvage therapy after MS obstruction due to tumor ingrowth, the median duration of MS patency was significantly shorter than that of threaded PS patency (123 vs. 240 days). Threaded PS are safe and effective in cases of malignant hilar obstruction; moreover, it is a suitable therapeutic option not only for initial drainage but also for salvage therapy.
Chemical etching of nitinol stents.
Katona, Bálint; Bognár, Eszter; Berta, Balázs; Nagy, Péter; Hirschberg, Kristóf
2013-01-01
At present the main cause of death originates from cardiovascular diseases. Primarily the most frequent cause is vessel closing thus resulting in tissue damage. The stent can help to avoid this. It expands the narrowed vessel section and allows free blood flow. The good surface quality of stents is important. It also must have adequate mechanical characteristics or else it can be damaged which can easily lead to the fracture of the implant. Thus, we have to consider the importance of the surface treatment of these implants. In our experiments the appropriate design was cut from a 1.041 mm inner diameter and 0.100 mm wall thickness nitinol tube by using Nd:YAG laser device. Then, the stent was subjected to chemical etching. By doing so, the burr created during the laser cutting process can be removed and the surface quality refined. In our research, we changed the time of chemical etching and monitored the effects of this parameter. The differently etched stents were subjected to microscopic analysis, mass measurement and in vivo environment tests. The etching times that gave suitable surface and mechanical features were identified.
Diabetes mellitus: a prothrombotic state Implications for outcomes after coronary revascularization
Cola, Clarissa; Brugaletta, Salvatore; Yuste, Victoria Martín; Campos, Bieito; Angiolillo, Dominick J; Sabaté, Manel
2009-01-01
Coronary stent thrombosis is a serious problem in the drug-eluting stent era. Despite aggressive antiplatelet therapy during and after percutaneous coronary intervention (PCI), the incidence of sub-acute stent thrombosis remains approximately 0.5%–2%, which may represent a catastrophic clinical situation. Both procedural factors and discontinuation of antiplatelet therapy are normally associated with this event. We report on simultaneous stent thromboses of two drug-eluting stents implanted in two different vessels, which resulted in a life-threatening clinical condition. Possible contributing factors that led to synergistic thrombotic effects are discussed. PMID:19436654
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tsauo Jiaywei, E-mail: 80732059@qq.com; Li Xiao, E-mail: simonlixiao@gmail.com; Li Hongcui, E-mail: lihongcui520@126.com
This study was designed to investigate retrospectively the feasibility of transjugular insertion of biliary stent (TIBS) for the treatment of distal malignant obstructive jaundice complicated by coagulopathy. Between April 2005 and May 2010, six patients with distal malignant obstructive jaundice associated with coagulopathy that was unable to be corrected underwent TIBS at our institution for the palliation of jaundice. Patients' medical record and imaging results were reviewed to obtain information about demographics, procedure details, complications, and clinical outcomes. The intrahepatic biliary tract was successfully accessed in all six patients via transjugular approach. The procedure was technically successfully in five ofmore » six patients, with a bare-metal stent implanted after traversing the biliary strictures. One procedure failed, because the guidewire could not traverse the biliary occlusion. One week after TIBS, the mean serum bilirubin in the five successful cases had decreased from 313 {mu}mol/L (range 203.4-369.3) to 146.2 {mu}mol/L (range 95.8-223.3) and had further decreased to 103.6 {mu}mol/L (range 29.5-240.9) at 1 month after the procedure. No bleeding, sepsis, or other major complications were observed after the procedure. The mean survival of these five patients was 4.5 months (range 1.9-5.8). On imaging follow-up, there was no evidence of stent stenosis or migration, with 100 % primary patency. When the risks of hemorrhage from percutaneous transhepatic cholangiodrainage are high, TIBS may be an effective alternative for the treatment of distal malignant obstructive jaundice.« less
Ureteric stent dwelling time: a risk factor for post-ureteroscopy sepsis.
Nevo, Amihay; Mano, Roy; Baniel, Jack; Lifshitz, David A
2017-07-01
To evaluate the association between stent dwelling time and sepsis after ureteroscopy, and identify risk factors for sepsis in this setting. The prospectively collected database of a single institution was queried for all patients who underwent ureteroscopy for stone extraction between 2010 and 2016. Demographic, clinical, preoperative and operative data were collected. The primary study endpoint was sepsis within 48 h of ureteroscopy. Logistic regressions were performed to identify predictors of post-ureteroscopy sepsis in the ureteroscopy cohort and specifically in patients with prior stent insertion. Between October 2010 and April 2016, 1 256 patients underwent ureteroscopy for stone extraction. Risk factors for sepsis included prior stent placement, female gender and Charlson comorbidity index. A total of 601 patients had a ureteric stent inserted before the operation and were included in the study cohort, in which the median age was 56 years, 90 patients were women (30%), and 97 patients were treated for positive preoperative urine cultures (16.1%). Postoperative sepsis, <48 h after surgery, occurred in eight (1.2%) non-stented patients and in 28 patients (4.7%) with prior stent insertion. Sepsis rates after stent dwelling times of 1, 2, 3 and >3 months were 1, 4.9, 5.5 and 9.2%, respectively. On multivariate analysis, stent dwelling time, stent insertion because of sepsis, and female gender were significantly associated with post-ureteroscopy sepsis in patients with prior stent placement. Patients who undergo ureteroscopy after ureteric stent insertion have a higher risk of postoperative sepsis. Prolonged stent dwelling time, sepsis as an indication for stent insertion, and female gender are independent risk factors. Stent placement should be considered cautiously, and if inserted, ureteroscopy should be performed within 1 month. © 2017 The Authors BJU International © 2017 BJU International Published by John Wiley & Sons Ltd.
Gotway, Michael B; Golden, Jeffrey A; LaBerge, Jeanne M; Webb, W Richard; Reddy, Gautham P; Wilson, Mark W; Kerlan, Robert K; Gordon, Roy L
2002-01-01
To determine the short- and long-term improvement in airflow dynamics in patients undergoing tracheobronchial stent placement for benign airway stenoses. Twenty-two patients underwent 34 tracheal and/or bronchial stent placement procedures for benign airway stenoses and had the results of pulmonary function tests available. Stent placement indications included bronchomalacia after lung transplantation (n = 11), postintubation stenoses (n = 6), relapsing polychondritis (n = 2), and 1 each of tracheomalacia, tracheal compression, and histoplasmosis. Six patients underwent more than one stent placement procedure (range: 2-7 procedures). The mean forced expiratory volume in one second (FEV(1) ), forced expiratory flow rate in the midportion of the forced vital capacity curve (FEF(25-75) ), forced vital capacity, and peak flow (PF) rate obtained before stent placement were compared with those immediately after stent placement and with those measurements most remote from stent placement using the paired two-tailed test. All patients reported improved respiratory function immediately after stent placement. The mean FEV(1), FEF(25-75), and PF rate improved significantly (p < 0.001, p = 0.002, and p = 0.009, respectively) after stent placement. On long-term follow-up averaging 15 months after stent placement, these parameters declined despite patients' subjective sense of improvement. Segregating the population into transplant and nontransplant airway stenosis etiologies, however, FEF(25-75) and PF rate remained significantly improved (p = 0.045, p = 0.027, respectively), over the long term for the latter. FEV increased after subsequent stent placements for patients receiving multiple stents. Stent placement for benign tracheobronchial stenoses provides significant immediate improvement in airflow dynamics. Long-term improvement in airflow obstruction may be expected, and additional stent placements may further improve pulmonary function.
Isayama, Hiroyuki; Mukai, Tsuyoshi; Itoi, Takao; Maetani, Iruru; Nakai, Yousuke; Kawakami, Hiroshi; Yasuda, Ichiro; Maguchi, Hiroyuki; Ryozawa, Shomei; Hanada, Keiji; Hasebe, Osamu; Ito, Kei; Kawamoto, Hirofumi; Mochizuki, Hitoshi; Igarashi, Yoshinori; Irisawa, Atsushi; Sasaki, Tamito; Togawa, Osamu; Hara, Taro; Kamada, Hideki; Toda, Nobuo; Kogure, Hirofumi
2012-07-01
Covered self-expandable metal stents (CSEMSs) were developed to prevent tumor ingrowth, but stent migration is one of the problems with CSEMSs. To evaluate a new, commercially available CSEMS with flared ends and low axial force compared with a commercially available CSEMS without the anti-migration system and high axial force. Multicenter, prospective study with a historical cohort. Twenty Japanese referral centers. This study involved patients with unresectable distal malignant biliary obstruction. Placement of a new, commercially available, partially covered SEMS. Recurrent biliary obstruction rate, time to recurrent biliary obstruction, stent-related complications, survival. Between April 2009 and March 2010, 141 patients underwent partially covered nitinol stent placement, and between May 2001 and January 2007, 138 patients underwent placement of partially covered stainless stents as a historical control. The silicone cover of the partially covered nitinol stents prevented tumor ingrowth. There were no significant differences in survival (229 vs 219 days; P = .250) or the rate of recurrent biliary obstruction (33% vs 38%; P = .385) between partially covered nitinol stents and partially covered stainless stents. Stent migration was less frequent (8% vs 17%; P = .019), and time to recurrent biliary obstruction was significantly longer (373 vs 285 days; P = .007) with partially covered nitinol stents. Stent removal was successful in 26 of 27 patients (96%). Nonrandomized, controlled trial. Partially covered nitinol stents with an anti-migration system and less axial force demonstrated longer time to recurrent biliary obstruction with no tumor ingrowth and less stent migration. Copyright © 2012 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pai, Madhava, E-mail: madhava.pai@imperial.ac.uk; Valek, Vlastimil; Tomas, Andrasina
PurposeThe major complication occurring with biliary stents is stent occlusion, frequently seen because of tumour in-growth, epithelial hyperplasia, and sludge deposits, resulting in recurrent jaundice and cholangitis. We report a prospective study with the results of first in man percutaneous intraductal radiofrequency (RF) ablation to clear the blocked metal stents in patients with malignant biliary obstruction using a novel bipolar RF catheter.MethodsNine patients with malignant biliary obstruction and blocked metal stents were included. These patients underwent intraductal biliary RF ablation through the blocked metal stent following external biliary decompression with an internal–external biliary drainage.ResultsAll nine patients had their stent patencymore » restored successfully without the use of secondary stents. Following this intervention, there was no 30-day mortality, haemorrhage, bile duct perforation, bile leak, or pancreatitis. Of the nine patients, six are alive and three patients are dead with a median follow-up of 122 (range 50–488) days and a median stent patency of 102.5 (range 50–321) days. Six patients had their stent patent at the time of last follow-up or death. Three patients with stent blockage at 321, 290, and 65 days postprocedure underwent percutaneous transhepatic drain insertion and repeat ablation.ConclusionsIn this selective group of patients, it appears that this new approach is safe and feasible. Efficacy remains to be proven in future, randomized, prospective studies.« less
Wissgott, Christian; Schmidt, Wolfram; Brandt-Wunderlich, Christoph; Behrens, Peter; Andresen, Reimer
2017-02-01
To report early clinical outcomes with a novel double-layer stent for the internal carotid artery (ICA) and the in vitro investigation of the stent's mechanical properties. A prospective single-center study enrolled 30 consecutive patients (mean age 73.1±6.3 years; 21 men) with symptomatic (n=25) or high-grade (n=5) ICA stenosis treated with the new double-layer carotid CGUARD Embolic Prevention System (EPS) stent, which has an inner open-cell nitinol design with an outer closed-cell polyethylene terephthalate layer. The average stenosis of the treated arteries was 84.1%±7.9% with a mean lesion length of 16.6±2.1 mm. In the laboratory, 8×40-mm stents where tested in vitro with respect to their radial force during expansion, the bending stiffness of the stent system and the expanded stent, as well as the collapse pressure in a thin and flexible sheath. The wall adaptation was assessed using fluoroscopy after stent release in step and curved vessel models. The stent was successfully implanted in all patients. No peri- or postprocedural complications occurred; no minor or major stroke was observed in the 6-month follow-up. The bending stiffness of the expanded stent was 63.1 N·mm 2 and (not unexpectedly) was clearly lower than that of the stent system (601.5 N·mm 2 ). The normalized radial force during expansion of the stent to 7.0 mm, consistent with in vivo sizing, was relatively high (0.056 N/mm), which correlates well with the collapse pressure of 0.17 bars. Vessel wall adaptation was harmonic and caused no straightening of the vessel after clinical application. Because of its structure, the novel CGUARD EPS stent is characterized by a high flexibility combined with a high radial force and very good plaque coverage. These first clinical results demonstrate a very safe implantation behavior without any stroke up to 6 months after the procedure.
Endoscopic stenting for benign upper gastrointestinal strictures and leaks.
Sharaiha, Reem Z; Kim, Katherine J; Singh, Vikesh K; Lennon, Anne Marie; Amateau, Stuart K; Shin, Eun Ji; Canto, Marcia Irene; Kalloo, Anthony N; Khashab, Mouen A
2014-01-01
Self-expandable metal stents (SEMS) and self-expandable plastic stents (SEPS) maybe used for the treatment of benign upper gastrointestinal (GI) leaks and strictures. This study reviewed our experience with stent insertions in patients with benign upper GI conditions. Patients who underwent stent placement for benign upper GI strictures and leaks between March 2007 and April 2011 at a tertiary referral academic center were studied using an endoscopic database and electronic patient records. The technical success, complications, and clinical improvement after stent removal were compared according to type of stent. The outcomes measured were clinical response, adverse events, and predictors of stent migration. Thirty-eight patients (50 % male, mean age = 54 years, range = 12-82) underwent 121 endoscopic procedures. Twenty patients had stents placed for strictures, and 18 had stents placed for leaks. Stent placement was technically successful in all patients. The average duration of stent placement was 54 days (range = 18-118). Clinical improvement immediately after stent placement was seen in 29 of the 38 patients (76.3 %). Immediate post-procedure adverse events occurred in 8 patients. Late adverse events were seen in 18 patients. Evidence of stent migration occurred in 16 patients and was seen in 42 of the 118 successfully placed stents (35.5 %). Migration was more frequent with fully covered SEMS (p = 0.002). After stent removal, 27 patients were evaluable for long-term success (median follow-up time of 283 days, IQR 38-762). Resolution of strictures or leaks was seen in 11 patients (40.7 %). Predictors for long-term success included increasing age and if the stent did not cross the GE junction. Placement of SEPS and SEMS for benign refractory strictures and fistulas has modest long-term clinical efficacy and is limited by a significant migration rate. Stent migration is common and frequent with fully covered SEMS compared to other types of stents, regardless of indication or location.
El-Said, Howaida; Hegde, Sanjeet; Moore, John
2014-01-01
The patient was a male infant with L-transposition of great arteries (L-TGA), Ebstein's anomaly of the tricuspid valve, subvalvar aortic stenosis, ventricular septal defect (VSD), hypoplastic right ventricle, arch hypoplasia, and congenital complete heart block. He underwent a Norwood procedure, aortic arch repair, permanent pacemaker implantation, and a 3.5-mm aortopulmonary shunt at 4 days of age. At the time of his surgery, left ventricular function was in the normal range (ejection fraction [EF] = 67%). However by 3 months of age, he was noted to have developed moderate-severe biventricular dysfunction (left ventricular ejection fraction [LVEF] = 34%). Atresia of the coronary sinus with a small left superior venacava (LSVC) and a bridging vein was discovered during cardiac catheterization at this time. The coronary sinus mean pressure was 17 mm Hg, and the common atrial mean pressure was 6 mmHg. We opened the atretic coronary sinus ostium using radiofrequency ablation and stent placement. There was dramatic improvement in ventricular function observed over a 2-month period. Follow-up cardiac catheterization 5 months later revealed the stent in the coronary sinus to be widely patent with no intimal buildup, and the ventricular function was normal (LVEF = 58%). The patient had a bidirectional Glenn procedure with an uncomplicated postoperative course and is currently awaiting Fontan completion. © 2013 Wiley Periodicals, Inc.
Xu, Guibin; Li, Xun; He, Yongzhong; Zhao, Haibo; Yang, Weiqing; Xie, Qingling
2015-10-01
To evaluate the safety and efficacy of self-expanding metal stents in the treatment of ureteral stenosis following kidney transplantation. Seven patients who developed benign stenosis after kidney transplantation were treated by a self-expanding metallic stent implantation from June 2007 to March 2014. All patients had undergone at least one open surgical procedure and one endourologic procedure for treatment of the stenosis. The extent of stenosis varied from 1.2 to 3.7 cm. Ultrasonography, urography, diuretic renography, and urine culture were performed every 3 months after stent insertion. Ureteroscopic examination was performed when needed. Stent placement was technically effective in all cases. The mean operative time was 37 minutes (range, 26-59 minutes). Lower urinary-tract symptoms and the ipsilateral flank pain were common early-stage complications and were greatly relieved after an average of 3 months. The mean follow-up duration was 38 months (range, 13-86 months), and no stent migration or fragmentation was observed. Urothelial hyperplasia occurred in only one patient and was effectively managed with a Double-J stent. Five patients had normal stable renal function; the remaining two had impaired renal function, including one patient with a preoperative renal failure who required dialysis at the end of the follow-up period (36 months). As an alternative to open surgery, implantation of a self-expanding metal stent is a safe and effective treatment for ureteral stenosis in patients who have undergone kidney transplantation.
NASA Astrophysics Data System (ADS)
Hoi, Yiemeng; Ionita, Ciprian N.; Tranquebar, Rekha V.; Hoffmann, Kenneth R.; Woodward, Scott H.; Taulbee, Dale B.; Meng, Hui; Rudin, Stephen
2006-03-01
An asymmetric stent with low porosity patch across the intracranial aneurysm neck and high porosity elsewhere is designed to modify the flow to result in thrombogenesis and occlusion of the aneurysm and yet to reduce the possibility of also occluding adjacent perforator vessels. The purposes of this study are to evaluate the flow field induced by an asymmetric stent using both numerical and digital subtraction angiography (DSA) methods and to quantify the flow dynamics of an asymmetric stent in an in vivo aneurysm model. We created a vein-pouch aneurysm model on the canine carotid artery. An asymmetric stent was implanted at the aneurysm, with 25% porosity across the aneurysm neck and 80% porosity elsewhere. The aneurysm geometry, before and after stent implantation, was acquired using cone beam CT and reconstructed for computational fluid dynamics (CFD) analysis. Both steady-state and pulsatile flow conditions using the measured waveforms from the aneurysm model were studied. To reduce computational costs, we modeled the asymmetric stent effect by specifying a pressure drop over the layer across the aneurysm orifice where the low porosity patch was located. From the CFD results, we found the asymmetric stent reduced the inflow into the aneurysm by 51%, and appeared to create a stasis-like environment which favors thrombus formation. The DSA sequences also showed substantial flow reduction into the aneurysm. Asymmetric stents may be a viable image guided intervention for treating intracranial aneurysms with desired flow modification features.
Intervention Therapy for Portal Vein Stenosis/Occlusion After Pediatric Liver Transplantation.
Gao, Haijun; Wang, Hao; Chen, Guang; Yi, Zhengjia
2017-04-18
BACKGROUND The aim of this study was to investigate the outcomes and stent implantation timing of portal vein stenosis intervention after pediatric liver transplantation (pLT). MATERIAL AND METHODS The clinical data of 30 children with post-liver transplantation portal vein stenosis/occlusion (PVS/O) between Jan 2008 and Jun 2015 were retrospectively analyzed. The successfully re-opened cases used balloon angioplasty or stent implantation. SPSS13.0 software was used for statistical analysis and paired t test of the pressure gradient at both ends of the stenosis, diameter and flow rate within the stenosis, platelet count, and albumin in the PVS children before and after balloon angioplasty, with p<0.05 considered as statistically significant. Among the 30 patients, 6 received a stent implant in their first treatment, 22 received balloon angioplasty in their first treatment, and in 2 the re-opening could not be achieved. RESULTS The diameter of the stenotic segment, portal vein velocity, pressure gradient at both ends of the stenosis, and platelet count in these children with portal vein stenosis/occlusion (PVS/O) showed statistically significant differences when comparing values before and after intervention (p<0.05), but albumin showed no statistically significant difference (p>0.05). CONCLUSIONS Intervention therapy for portal vein stenosis after pediatric liver transplantation (pLT-PVS) is a safe and effective treatment, and patients with portal vein torsion, intimal tearing, or long portal vein segment occlusion should undergo stent implantation.
Yun, Jong Hyouk; Jung, Gyoo-Sik; Park, Jung Gu; Kang, Byung Chul; Shin, Dong-Hoon; Yun, Byung Chul; Lee, Sang Uk
2016-04-01
To evaluate the technical feasibility and clinical efficacy of placement of a newly designed Y-shaped branched covered stent for palliative treatment of malignant hilar biliary obstruction. From June 2011 to September 2014, 34 consecutive patients with malignant hilar biliary obstruction underwent percutaneous placement of a Y-shaped branched covered stent for palliative treatment. Technical and clinical success, complications, cumulative patient survival, and stent patency were evaluated. Stent placement was technically successful in all patients. All patients showed adequate biliary drainage on the follow-up cholangiogram. Mean serum bilirubin level (10.9 mg/dl) decreased significantly 1 week (5.7 mg/dl) and 1 month (2.6 mg/dl) after stent placement (p < 0.01). Complications associated with the procedure included hemobilia (n = 3) and biloma (n = 1). During the mean follow-up period of 225 (range 12-820) days, nine patients (26.5%) developed stent occlusion caused by tumor overgrowth (n = 8) and sludge (n = 1). Two of them underwent coaxial placement of a second stent with good results. The median survival time was 281 days and median primary stent patency was 337 days. There were no significant differences in the patient survival and stent patency rates in relation to age, sex, or Bismuth type. Percutaneous placement of the Y-shaped branched covered stent seems to be technically feasible and clinically effective for palliative treatment of malignant hilar biliary obstruction.
Expandable right ventricular-to-pulmonary artery conduit: an animal study.
Boudjemline, Younes; Laborde, François; Pineau, Emmanuelle; Mollet, Alix; Abadir, Sylvia; Borenstein, Nicolas; Behr, Luc; Bonhoeffer, Philipp
2006-06-01
This study was performed to assess a new vascular stent graft as an expandable valved conduit for right ventricular outflow tract (RVOT) reconstruction in sheep. Conduits were constructed by sewing an 18-mm valved conduit inside a stent. Crimped to 16 mm, they were implanted either under or without extracorporeal circulation in seven (group A) and in five (group B) sheep, respectively. Six weeks and 3 mo after their insertion, conduits were dilated intraluminally. A valved stent was implanted percutaneously into conduits before they were killed. Two animals from group A recovered normally, whereas five animals had a complicated postoperative course. In group B, one died acutely due to kinking of the conduit. Balloon dilatations were performed in all surviving animals. First dilatations had a slight impact on valvular function in all animals but one, whereas second dilatations led to significant PR in all. Transcatheter valve implantation was performed successfully. When animals were killed, no bleeding was found around the surgically implanted device. In conclusion, we designed a biologic valved conduit for RVOT reconstruction that can be dilated sequentially to follow animal growth. This new device can have tremendous applications in children with congenital heart diseases involving the RVOT.
A Critical Review on Metallic Glasses as Structural Materials for Cardiovascular Stent Applications.
Jafary-Zadeh, Mehdi; Praveen Kumar, Gideon; Branicio, Paulo Sergio; Seifi, Mohsen; Lewandowski, John J; Cui, Fangsen
2018-02-27
Functional and mechanical properties of novel biomaterials must be carefully evaluated to guarantee long-term biocompatibility and structural integrity of implantable medical devices. Owing to the combination of metallic bonding and amorphous structure, metallic glasses (MGs) exhibit extraordinary properties superior to conventional crystalline metallic alloys, placing them at the frontier of biomaterials research. MGs have potential to improve corrosion resistance, biocompatibility, strength, and longevity of biomedical implants, and hence are promising materials for cardiovascular stent applications. Nevertheless, while functional properties and biocompatibility of MGs have been widely investigated and validated, a solid understanding of their mechanical performance during different stages in stent applications is still scarce. In this review, we provide a brief, yet comprehensive account on the general aspects of MGs regarding their formation, processing, structure, mechanical, and chemical properties. More specifically, we focus on the additive manufacturing (AM) of MGs, their outstanding high strength and resilience, and their fatigue properties. The interconnection between processing, structure and mechanical behaviour of MGs is highlighted. We further review the main categories of cardiovascular stents, the required mechanical properties of each category, and the conventional materials have been using to address these requirements. Then, we bridge between the mechanical requirements of stents, structural properties of MGs, and the corresponding stent design caveats. In particular, we discuss our recent findings on the feasibility of using MGs in self-expandable stents where our results show that a metallic glass based aortic stent can be crimped without mechanical failure. We further justify the safe deployment of this stent in human descending aorta. It is our intent with this review to inspire biodevice developers toward the realization of MG-based stents.
A Critical Review on Metallic Glasses as Structural Materials for Cardiovascular Stent Applications
Jafary-Zadeh, Mehdi; Praveen Kumar, Gideon
2018-01-01
Functional and mechanical properties of novel biomaterials must be carefully evaluated to guarantee long-term biocompatibility and structural integrity of implantable medical devices. Owing to the combination of metallic bonding and amorphous structure, metallic glasses (MGs) exhibit extraordinary properties superior to conventional crystalline metallic alloys, placing them at the frontier of biomaterials research. MGs have potential to improve corrosion resistance, biocompatibility, strength, and longevity of biomedical implants, and hence are promising materials for cardiovascular stent applications. Nevertheless, while functional properties and biocompatibility of MGs have been widely investigated and validated, a solid understanding of their mechanical performance during different stages in stent applications is still scarce. In this review, we provide a brief, yet comprehensive account on the general aspects of MGs regarding their formation, processing, structure, mechanical, and chemical properties. More specifically, we focus on the additive manufacturing (AM) of MGs, their outstanding high strength and resilience, and their fatigue properties. The interconnection between processing, structure and mechanical behaviour of MGs is highlighted. We further review the main categories of cardiovascular stents, the required mechanical properties of each category, and the conventional materials have been using to address these requirements. Then, we bridge between the mechanical requirements of stents, structural properties of MGs, and the corresponding stent design caveats. In particular, we discuss our recent findings on the feasibility of using MGs in self-expandable stents where our results show that a metallic glass based aortic stent can be crimped without mechanical failure. We further justify the safe deployment of this stent in human descending aorta. It is our intent with this review to inspire biodevice developers toward the realization of MG-based stents. PMID:29495521
Double bifurcation optimization stent system technique for left main stenosis.
Vassilev, D; Mateev, H; Alexandrov, A; Karamfiloff, K; Gil, R J
2014-12-01
We present a first-in-man case with implantation in culottes' fashion of two dedicated coronary bifurcation stents (BiOSS Lim) in distal left main stenosis. The immediate procedural and very short-term result was excellent. © 2014, Wiley Periodicals, Inc.
Ibrahim, Hamdy M; Mohyelden, Khaled; Abdel-Bary, Ahmed; Al-Kandari, Ahmed M
2015-10-01
Endoureterotomy is a viable option for treating patients with benign ureteral stricture. We compared the efficacy and safety of double versus single ureteral stent placement after laser endoureterotomy. This study included 55 patients with benign ureteral strictures; all patients underwent retrograde laser endoureterotomy. Patients were randomized either to single or double ureteral stents. Single stents were placed in 27 ureters while double stents were placed in 28 ureters. The stent diameter used was 7 F, and stents were indwelling for 8 weeks. Imaging was performed 1 month after stent removal and repeated regularly every 3 months. Clinical characteristics, operative results, and functional outcomes were compared for strictures managed in both groups. Success was evaluated both subjectively and objectively. Fifty-five patients with a mean age of 46 (16-75) years had benign ureteral strictures; the mean stricture length was 1.92 (1-3) cm. The mean follow-up was 25.7 (9-42) months. The overall success rate was 67.3% (37 patients) with no radiologic evidence of obstruction, 6 (10.9%) patients showed symptomatic improvement while 12 (21.8%) patients underwent surgical reconstruction. Success was significantly higher for ureteral strictures (>1.5 cm) managed with double stent placement (82.4%), compared with single stent placement (38.9%) with a P value of 0.009. Double stent placement of the ureter after laser endoureterotomy achieved a higher success rate compared with single stent placement in cases of benign ureteral strictures. Although ureteral strictures (≤1.5 cm) achieved better outcome after laser endoureterotomy, strictures (>1.5 cm) favored better with double stent versus single stent placement.
Biodegradable Stents for Caustic Esophageal Strictures: Do They Work?
Kochhar, Rakesh; Samanta, Jayanta; Basha, Jahangeer; Verma, Abhai; Choudhuri, Gourdas; Lakhtakia, Sundeep; Reddy, D Nageshwar
2017-08-01
Biodegradable (BD) stents have been used for the management of various esophageal strictures (ES) but the experience of its use in caustic strictures is limited. The present study, aimed at evaluating efficacy of BD stents for the treatment of refractory caustic-induced ES, was a retrospective multi-center study conducted at three tertiary care centers in India wherein adult patients with refractory caustic induced strictures underwent placement of a BD stent. Patients were followed up for immediate complications and long term outcome. All 13 patients (39.3 ± 15.1 years) underwent successful BD stent placement. Retrosternal chest pain occurred in 2 patients and stent migration in 1 (7.6%) patient. At 3 months, restenosis with recurrence of dysphagia was seen in nine (69.2%) patients, at 6 months, 10 (77%) patients had dysphagia of whom three underwent surgery and the remaining seven patients required dilatations. At 1 year, one patient remained asymptomatic while nine had dysphagia. The requirement for dilatation was once in 3 months in seven patients & once in a month in two patients. At 2 years, the requirement of dilatations was further reduced to once in 4-6 months in all patients. Over a 3 year follow up three (23%) patients had undergone surgery, one was free of symptoms while nine patients continued to be on periodic dilatation although the requirement had reduced to once in 4-6 months. Efficacy of BD stents in patients with caustic-induced ES is limited and the short term radial force applied by the currently available BD stents is inadequate to provide long term relief in such patients.
Kang, Dong Hyuk; Cho, Kang Su; Ham, Won Sik; Chung, Doo Yong; Kwon, Jong Kyou; Choi, Young Deuk; Lee, Joo Yong
2016-11-01
To evaluate ureteral stenting as a negative predictive factor influencing ureteral stone clearance and to estimate the probability of one-session success in shock wave lithotripsy (SWL) patients with a ureteral stone. We retrospectively reviewed the medical records of 1,651 patients who underwent their first SWL. Among these patients, 680 had a ureteral stone measuring 4-20 mm and were thus eligible for our study. The 57 patients who underwent ureteral stenting during SWL were identified. Maximal stone length (MSL), mean stone density (MSD), skin-to-stone distance (SSD), and stone heterogeneity index (SHI) were determined by pre-SWL noncontrast computed tomography. After propensity score matching, 399 patients were extracted from the total patient cohort. There were no significant differences between stenting and stentless groups after matching, except for a higher one-session success rate in the stentless group (78.6% vs. 49.1%, p=0.026). In multivariate analysis, shorter MSL, lower MSD, higher SHI, and absence of a stent were positive predictors for one-session success in patients who underwent SWL. Using cutoff values of MSL and MSD obtained from receiver operator curve analysis, in patients with a lower MSD (≤784 HU), the success rate was lower in those with a stent (61.1%) than in those without (83.5%) (p=0.001). However, in patients with a higher MSL (>10 mm), the success rate was lower in those with a stent (23.6%) than in those without (52.2%) (p=0.002). Ureteral stenting during SWL was a negative predictor of one-session success in patients with a ureteral stone.
Results From the VISIBILITY Iliac Study: Primary and Cohort Outcomes at 9 Months
Rundback, John H.; Peeters, Patrick; George, Jon C.; Jaff, Michael R.; Faries, Peter L.
2017-01-01
Purpose: To evaluate the safety and effectiveness of primary stenting of the common (CIA) or external iliac artery (EIA) using the Visi-Pro Balloon-Expandable Peripheral Stent System for treatment of stenotic, restenotic, or occluded lesions. Methods: Between 2011 and 2012, 75 patients (mean age 64.2±8.9 years; 46 men) with Rutherford category 2–4 ischemia and atherosclerotic lesions ≤10 cm in length underwent iliac artery stenting at 17 centers in the United States and Europe. The primary outcome of the study was the major adverse event (MAE) rate at 9 months postprocedure [composite of periprocedural death, in-hospital myocardial infarction, clinically driven target lesion revascularization (CD-TLR), and amputation of the treated limb]. Secondary outcomes included 30-day MAE rate, 9-month primary patency, changes in ankle-brachial index (ABI) and the Walking Impairment Questionnaire at 30 days and 9 months postprocedure, device success, and clinically driven target vessel revascularization (CD-TVR) at 30 days and 9 months. Outcomes in specific patient cohorts (ie, gender, stent location, calcification severity, and lesion grade) were analyzed. Results: Eighty-one stents were implanted in 61 CIA and 15 EIA lesions (41 with moderate/severe calcification). The mean lesion treated length was 29.3±13.9 mm. All devices were successfully deployed. MAE occurred in 3 (4.0%) of 75 subjects at 9 months. Primary patency and freedom from CD-TVR at 9 months were both 95.8%. ABI improved from 0.67±0.14 at baseline to 0.94±0.14 and 0.96±0.16 at 30 days and 9-month follow-up, respectively (p<0.001 for both). There were no differences with respect to any of the analyzed patient characteristics, including gender. Conclusion: Nine-month results of the VISIBILITY Iliac stent study (ClinicalTrials.gov identifier NCT01402700) demonstrated safety and effectiveness for the treatment of atherosclerotic CIA and EIA lesions with the Visi-Pro stent across all treated cohorts. PMID:28351204
An Unusual Case of Stent Migration After Celiac Trunk Endovascular Revascularization
DOE Office of Scientific and Technical Information (OSTI.GOV)
Negri, Silvia; Ferraro, Stefania; Piffaretti, Gabriele, E-mail: gabriele.piffaretti@uninsubria.it
2012-08-15
A 61-year-old woman underwent celiac trunk stenting to treat abdominal angina. Three months later, she was readmitted for recurrent symptoms. Computed tomography control revealed the migration of the stent into the splenic artery. No sign of vessel injury or end-organ ischemia was detected. Repeat stenting of the celiac trunk was performed; the postoperative course was uneventful. 12 months later, the patient was asymptomatic with the second stent in its correct position, and she was asymptomatic for mesenteric ischemia.
Successful silicon stent for life-threatening tracheal wall laceration.
Yamamoto, Shinichi; Endo, Shunsuke; Endo, Tetsuya; Mitsuda, Sayaka
2013-01-01
We report an 86-year-old woman with a large tracheal laceration caused by tracheal intubation at cardiopulmonary arrest who underwent a successful stent procedure. Tracheal laceration developed in the membranous portion longitudinally 6 cm in length to 2 cm above the carina. Following 9 days' tracheal intubation, a Y-shaped silicon stent was inserted over the lacerated trachea. Four months after the stenting procedure, we removed the Y-shaped silicon stent from the healed membranous wall. The patient returned to daily life without requiring thoracotomy.
Stent design favorably influences the vascular response in normal porcine coronary arteries.
Carter, A J; Scott, D; Rahdert, D; Bailey, L; De Vries J; Ayerdi, K; Turnlund, T; Jones, R; Virmani, R; Fischell, T A
1999-03-01
The purpose of this study was to compare the arterial response following implantation of a stainless-steel, balloon-expandable, tubular slotted stent with that of a novel computer-designed, multi-cellular stent in normal porcine coronary arteries. Intracoronary stent placement has evolved into the primary strategy for percutaneous revascularization of symptomatic coronary arterial lesions. Presently there is intense interest in developing new stent designs to improve stent delivery and biocompatability. Computer-assisted design was utilized to develop a balloon-expandable stent with symmetric expansion properties, uniform arterial wall coverage, longitudinal flexibility and radial strength. Quantitative coronary angiography and histological assessment of the stented arteries was used to evaluate the acute and chronic vascular responses to a stainless-steel, balloon-expandable, tubular slotted stent as compared to the computer-designed BX stent in the normolipemic swine. Forty stents (24 BX, 16 tubular slotted) were implanted in 19 miniature swine at a mean inflation pressure of 9 atm using identical delivery systems. Eight of the BX and none of the tubular slotted stents were post-dilated with a non-compliant balloon at 12-14 atm. The mean stent-to-artery ratio was similar for the BX (1.03 +/- 0.06) and tubular slotted (1.04 +/- 0.11; p = 0.59) designs. Protrusion or asymmetric radial flaring of a strut at the stent margin was present in 1 of 23 BX stents (4.3%) and 10 of 15 tubular slotted stents (66.7%; p < 0.0001). The mean arterial injury score was significantly less for the BX stent (0.2 +/- 0.2) as compared with the tubular slotted stents (0.4 +/- 0.4; p = 0.025). At 3 days, thrombus area was similar for the BX and tubular slotted designs (0.42 +/- 0.16 mm2 versus 0.44 +/- 0.18 mm2, respectively; p = 0.88). The mean neointimal area was significantly less for the BX at 2 months (1.09 +/- 0.25 mm2 versus 2.93 +/- 2.26 mm2 in the tubular slotted stent) and at 6 months (1.10 +/- 0.26 mm2 versus 2.07 +/- 0.65 mm2 in the tubular slotted stent; p = 0.01), resulting in approximately 50% less in-stent stenosis. The arterial response to a balloon-expandable stent can be favorably influenced by computer-assisted modification of design in an experimental model. Further study is warranted to determine the impact of stent design upon clinical in-stent restenosis.
2013-01-01
Background Although endoscopic biliary stents have been accepted as part of palliative therapy for cases of malignant hilar obstruction, the optimal endoscopic management regime remains controversial. In this study, we evaluated the safety and efficacy of placing a threaded stent above the sphincter of Oddi (threaded inside plastic stents, threaded PS) and compared the results with those of other stent types. Methods Patients with malignant hilar obstruction, including those requiring biliary drainage for stent occlusion, were selected. Patients received either one of the following endoscopic indwelling stents: threaded PS, conventional plastic stents (conventional PS), or metallic stents (MS). Duration of stent patency and the incident of complication were compared in these patients. Results Forty-two patients underwent placement of endoscopic indwelling stents (threaded PS = 12, conventional PS = 17, MS = 13). The median duration of threaded PS patency was significantly longer than that of conventional PS patency (142 vs. 32 days; P = 0.04, logrank test). The median duration of threaded PS and MS patency was not significantly different (142 vs. 150 days, P = 0.83). Stent migration did not occur in any group. Among patients who underwent threaded PS placement as a salvage therapy after MS obstruction due to tumor ingrowth, the median duration of MS patency was significantly shorter than that of threaded PS patency (123 vs. 240 days). Conclusions Threaded PS are safe and effective in cases of malignant hilar obstruction; moreover, it is a suitable therapeutic option not only for initial drainage but also for salvage therapy. PMID:23410217
Percutaneous Treatment of Central Venous Stenosis in Hemodialysis Patients: Long-Term Outcomes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Young Chul; Won, Jong Yun, E-mail: jywon@yumc.yonsei.ac.kr; Choi, Sun Young
2009-03-15
The purpose of this study was to evaluate the long-term outcomes of endovascular treatment of central venous stenosis in patients with arteriovenous fistulas (AVFs) for hemodialysis. Five hundred sixty-three patients with AVFs who were referred for a fistulogram were enrolled in this study. Among them, 44 patients showed stenosis (n = 35) or occlusions (n = 9) in the central vein. For the initial treatment, 26 patients underwent percutaneous transluminal angioplasty (PTA) and 15 patients underwent stent placements. Periods between AVF formation and first intervention ranged from 3 to 144 months. Each patient was followed for 14 to 60 months.more » Procedures were successful in 41 of 44 patients (93.2%). Primary patency rates for PTA at 12 and 36 months were 52.1% and 20.0%, and assisted primary patency rates were 77.8% and 33.3%, respectively. Primary patency rates for stent at 12 and 36 months were 46.7% and 6.7%, and assisted primary patency rates were 60.0% and 20.0%, respectively. Fifteen of 26 patients with PTAs underwent repeated interventions because of restenosis. Fourteen of 15 patients with a stent underwent repeated interventions because of restenosis and combined migration (n = 1) and shortening (n = 6) of the first stent. There was no significant difference in patency between PTAs and stent placement (p > 0.05). Average AVF patency duration was 61.8 months and average number of endovascular treatments was 2.12. In conclusion, endovascular treatments of central venous stenosis could lengthen the available period of AVFs. There was no significant difference in patency between PTAs and stent placement.« less
Biomimicry, vascular restenosis and coronary stents.
Schwartz, R S; van der Giessen, W J; Holmes, D R
1998-01-01
Biomimicry is in its earliest stages and is being considered in the realm of tissue engineering. If arterial implants are to limit neointimal thickening, purely passive structures cannot succeed. Bioactivity must be present, either by pharmacologic intervention or by fabricating a 'living stent' that contains active cellular material. As tissue engineering evolves, useful solutions will emerge from applying this knowledge directly to vascular biologic problems resulting from angioplasty, stenting, and vascular prosthesis research.
Mair, E A; Parsons, D S; Lally, K P; Van Dellen, A F
1991-09-01
Present surgical alternatives for pediatric tracheobronchomalacia are limited and associated with many potentially undesirable complications. The feasibility of different intraluminal expandable endotracheal stents for the treatment of surgically induced tracheomalacia was analyzed in 27 piglets. A potentially fatal tracheomalacia was surgically created. Either a stainless steel "zig-zag" stent or a woven polymeric stent was then implanted. Tracheal patency, mucosal function, histopathologic respiratory tract changes, and effects of the stent on esophageal motility were evaluated over a 16-week period. Piglets with steel stents uniformly experienced intense inflammation leading to tracheal dysfunction and death. Piglets with polymeric stents experienced minimal respiratory symptoms. Expandable polymeric endotracheal stents alleviate surgically induced piglet tracheomalacia, were easy to insert, allowed for tracheal growth, and reduced the need for high-risk surgical procedures with prolonged ventilatory support.
Wang, Juan; Liu, Lumei; Wu, Yifan; Maitz, Manfred F; Wang, Zhihong; Koo, Youngmi; Zhao, Ansha; Sankar, Jagannathan; Kong, Deling; Huang, Nan; Yun, Yeoheung
2017-03-01
Current in vitro models fail in predicting the degradation rate and mode of magnesium (Mg) stents in vivo. To overcome this, the microenvironment of the stent is simulated here in an ex vivo bioreactor with porcine aorta and circulating medium, and compared with standard static in vitro immersion and with in vivo rat aorta models. In ex vivo and in vivo conditions, pure Mg wires were exposed to the aortic lumen and inserted into the aortic wall to mimic early- and long-term implantation, respectively. Results showed that: 1) Degradation rates of Mg were similar for all the fluid diffusion conditions (in vitro static, aortic wall ex vivo and in vivo); however, Mg degradation under flow condition (i.e. in the lumen) in vivo was slower than ex vivo; 2) The corrosion mode in the samples can be mainly described as localized (in vitro), mixed localized and uniform (ex vivo), and uniform (in vivo); 3) Abundant degradation products (MgO/Mg(OH) 2 and Ca/P) with gas bubbles accumulated around the localized degradation regions ex vivo, but a uniform and thin degradation product layer was found in vivo. It is concluded that the ex vivo vascular bioreactor provides an improved test setting for magnesium degradation between static immersion and animal experiments and highlights its promising role in bridging degradation behavior and biological response for vascular stent research. Magnesium and its alloys are candidates for a new generation of biodegradable stent materials. However, the in vitro degradation of magnesium stents does not match the clinical degradation rates, corrupting the validity of conventional degradation tests. Here we report an ex vivo vascular bioreactor, which allows simulation of the microenvironment with and without blood vessel integration to study the biodegradation of magnesium implants in comparison with standard in vitro test conditions and with in vivo implantations. The bioreactor did simulate the corrosion of an intramural implant very well, but showed too high degradation for non-covered implants. It is concluded that this system is in between static incubation and animal experiments concerning the predictivity of the degradation. Copyright © 2016 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Gambhir, D S; Batra, R; Singh, S; Sudha, R; Trehen, V; Arora, R
1998-01-01
Lesions at the ostium of the left anterior descending coronary artery constitute a distinct group because of suboptimal results and higher restenosis rate after balloon angioplasty. Several non-balloon devices have been used to improve the outcome of dilatation of such lesions. We retrospectively compared the in-hospital and follow-up results of directional coronary artherectomy and stents for the treatment of ostial lesions of the left anterior descending artery. Out of 37 patients, 12 underwent directional coronary atherectomy and 25, stent implantation. The two strategies were deployed at different periods over the past five years. The baseline clinical and angiographic characteristics were comparable in the two groups. Directional coronary atherectomy was done using 7Fr atherocath with adjunctive balloon angioplasty in all. All the stents were deployed using moderate to high pressure balloon inflation after adequate predilatation. While the pre-procedure luminal diameter stenosis was similar in the two groups (87.3 +/- 8.8% vs 89.3 +/- 7.2%; p = NS), the residual stenosis was significantly lower in the stent group (5 +/- 2.8%) compared to directional coronary atherectomy (18.7 +/- 9.8; p = 0.02). There was no significant difference in the primary success rate between the two devices (91.6% directional coronary atherectomy vs 100% stent; p = NS). One patient in the directional coronary atherectomy group developed acute closure followed by emergency coronary artery bypass graft surgery and death. No major complication was observed in the stent group. Over a mean follow-up of 9.9 +/- 11.6 months following directional coronary atherectomy and 8.6 +/- 4.4 months after stenting, significantly higher number of patients (60%) developed recurrence of angina or any event following directional coronary atherectomy compared to stent (15.8%; p < 0.02). There was no myocardial infarction, coronary artery bypass graft surgery or death in either group on follow-up. The need for target lesion revascularisation was significantly higher in the directional coronary atherectomy group (50%) compared to stenting (10.5%; p < 0.02). Comparing directional coronary atherectomy with stent, the event-free survival was 80 percent vs 94.7 percent at three months and 50 percent vs 84.7 percent, both at six and nine months, respectively. In conclusion, stenting of the left anterior descending artery ostial lesion results in a significantly lesser post-procedure residual stenosis, improved in-hospital outcome, a lesser need for target lesion revascularisation and much improved event-free survival on follow-up as compared to directional coronary atherectomy. Therefore, stenting appears to be a more favourable treatment option compared to directional coronary atherectomy for the treatment of ostial lesions in the left anterior descending artery.
Tracheal T-Tube Stent for Laryngotracheal Stenosis: Ten Year Experience
Dass, Arjun; M Nagarkar, Nitin; K Singhal, Surinder; Verma, Hitesh
2014-01-01
Introduction: The purpose of this retrospective study was to evaluate the outcome following stenting over a period of 10 years in patients with chronic laryngotracheal stenosis. Materials and Methods: Between 2000–2010, out of 111 patients with laryngotracheal trauma, 71 underwent tracheal T-stenting for laryngotracheal stenosis in the Department of Otorhinolaryngology at the Government Medical College and Hospital, Chandigarh, India. All 71 patients underwent stenting by tracheal T-stent through an external approach. The follow-up period ranged from 3–10 years (mean, 3.2 years). The tracheal T-stent was removed after a minimum period of 6–12 months. Results: The majority of patients in this study were aged less than 10 years or between the ages of 20–30 years. A pre-operative tracheostomy (emergency or elective) was performed in all patients. of 71 patients, decannulation was not possible in six (8%). Conclusion: Management of laryngotracheal stenosis is a challenging problem that demands a multidisciplinary approach from surgical teams well trained in this field. The ideal treatment option should be individualized according to patient characteristics. The use of silastic stents has both advantages and disadvantages. PMID:24505573
Endovascular management of early lung transplant-related anastomotic pulmonary artery stenosis.
Anaya-Ayala, Javier E; Loebe, Matthias; Davies, Mark G
2015-06-01
To report the safety and short-term efficacy of endovascular interventions for symptomatic lung transplant-related anastomotic pulmonary artery stenosis (PAS). From February 2008 to December 2011, 354 lung transplants were performed. Pulmonary arteriography was performed in 19 patients (63% men; age, 57 y ± 21, mean ± SD; seven double-lung transplants) because of respiratory decompensation (mean 6.7 mo after transplant). Seven arteriograms were normal, and 12 showed significant PAS. One patient (5%) underwent angioplasty alone, and 11 patients (57%) underwent stent placement. All patients underwent general anesthesia, and femoral access was used for the intervention. Technical success was 100% in the 12 patients treated. Symptoms improved in all patients who underwent intervention, with resolution in 11 of 12 (92%). There were no major or minor complications. Three patients (16%) had recurrent symptoms after discharge secondary to chronic rejection or pneumonia. Two patients died as a result of sepsis and multiorgan failure at 2 days and 14 days, respectively, after undergoing only pulmonary arteriography. In-stent stenosis occurred in 1 (9%) patient who required additional stent placement. During a mean follow-up period of 11 months, the remaining stents were patent, and the patients were asymptomatic. Endovascular stent placement provides an alternative to open repair for transplant-related anastomotic PAS. It has low mortality and morbidity rates, and it has shown excellent short-term functional and anatomic outcomes. Copyright © 2015 SIR. Published by Elsevier Inc. All rights reserved.
Paclitaxel Drug-eluting Tracheal Stent Could Reduce Granulation Tissue Formation in a Canine Model
Wang, Ting; Zhang, Jie; Wang, Juan; Pei, Ying-Hua; Qiu, Xiao-Jian; Wang, Yu-Ling
2016-01-01
Background: Currently available silicone and metallic stents for tracheal stenosis are associated with many problems. Granulation proliferation is one of the main complications. The present study aimed to evaluate the efficacy of paclitaxel drug-eluting tracheal stent in reducing granulation tissue formation in a canine model, as well as the pharmacokinetic features and safety profiles of the coated drug. Methods: Eight beagles were randomly divided into a control group (bare-metal stent group, n = 4) and an experimental group (paclitaxel-eluting stent group, n = 4). The observation period was 5 months. One beagle in both groups was sacrificed at the end of the 1st and 3rd months, respectively. The last two beagles in both groups were sacrificed at the end of 5th month. The proliferation of granulation tissue and changes in tracheal mucosa were compared between the two groups. Blood routine and liver and kidney function were monitored to evaluate the safety of the paclitaxel-eluting stent. The elution method and high-performance liquid chromatography were used to characterize the rate of in vivo release of paclitaxel from the stent. Results: Compared with the control group, the proliferation of granulation tissue in the experimental group was significantly reduced. The drug release of paclitaxel-eluting stent was the fastest in the 1st month after implantation (up to 70.9%). Then, the release slowed down gradually. By the 5th month, the release reached up to 98.5%. During the observation period, a high concentration of the drug in the trachea (in the stented and adjacent unstented areas) and lung tissue was not noted, and the blood test showed no side effect. Conclusions: The paclitaxel-eluting stent could safely reduce the granulation tissue formation after stent implantation in vivo, suggesting that the paclitaxel-eluting tracheal stent might be considered for potential use in humans in the future. PMID:27824004
Wang, Bin; Mintz, Gary S; Witzenbichler, Bernhard; Souza, Cristiano F; Metzger, D Christopher; Rinaldi, Michael J; Duffy, Peter L; Weisz, Giora; Stuckey, Thomas D; Brodie, Bruce R; Matsumura, Mitsuaki; Yamamoto, Myong-Hwa; Parvataneni, Rupa; Kirtane, Ajay J; Stone, Gregg W; Maehara, Akiko
2016-12-22
The impact of acute stent malapposition (ASM) on long-term clinical outcomes in patients undergoing percutaneous coronary intervention is still controversial. We sought to evaluate predictors and long-term clinical outcomes of ASM. ADAPT-DES (Assessment of Dual Antiplatelet Therapy With Drug-Eluting Stents) was a prospective multicenter study of 8663 patients undergoing percutaneous coronary intervention using drug-eluting stents. In a prespecified intravascular ultrasound-guided substudy, 2072 patients with 2446 culprit lesions had post-percutaneous coronary intervention intravascular ultrasound and were classified according to the presence or absence of ASM. After intravascular ultrasound-guided percutaneous coronary intervention, the overall prevalence of ASM after successful drug-eluting stents implantation was 14.4% per patient and 12.6% per lesion. Compared to lesions without ASM, lesions with ASM had larger in-stent lumen areas, larger stent areas, and larger in-stent vessel areas. A larger mean plaque area along with more attenuated plaque was observed in lesions with ASM versus lesions without ASM. Lesions with ASM had greater proximal and distal reference lumen areas and more distal, but not proximal, reference calcium compared to lesions without ASM. At 2-year follow-up, there was no significant difference in the incidence of cardiac death; myocardial infarction; early, late, or very late stent thrombosis; or clinically driven target lesion revascularization in patients with ASM versus those without ASM. Furthermore, ASM was not an independent predictor of 2-year major adverse cardiac events or target lesion revascularization even when forced into the multivariate model. In patients treated with intravascular ultrasound-guided drug-eluting stents implantation, ASM was not associated with adverse clinical events during long-term follow-up including, but not limited to, stent thrombosis. URL: https://www.clinicaltrials.gov. Unique identifier: NCT00638794. © 2016 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.
Liu, Chia-Hsin; Huang, Wen-Sheng; Wang, Hong-Hau; Wu, Chin-Pyng; Chian, Chih-Feng; Perng, Wann-Cherng; Tsai, Chen-Liang
2015-02-01
Tracheomalacia can cause variable degrees of intrathoracic airway obstruction and is an easily overlooked cause of respiratory distress in adults. Here, we report a case of acute respiratory failure in which subglottic stenosis was accidentally identified during endotracheal intubation. Subsequent bronchoscopy and computed tomography of the thorax and neck revealed tracheal compression with tracheomalacia caused by a tortuous innominate artery and a kyphotic cervical spine. The patient underwent rigid bronchoscopy with metal stent implantation, and her symptoms were alleviated. These findings outline the importance of precise diagnosis and interventions for preventing recurrent life-threatening respiratory failure in such cases. Copyright © 2015 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Karpov, Yu; Logunova, N; Tomilova, D; Buza, V; Khomitskaya, Yu
2017-02-01
The OPTIMA II study sought to evaluate rates of major adverse cardiac and cerebrovascular events (MACCEs) during the long-term follow-up of chronic statin users who underwent percutaneous coronary intervention (PCI) with implantation of a drug-eluting stent (DES). OPTIMA II was a non-interventional, observational study conducted at a single center in the Russian Federation. Included patients were aged ≥18 years with stable angina who had received long-term (≥1 month) statin therapy prior to elective PCI with DES implantation and who had participated in the original OPTIMA study. Patients received treatment for stable angina after PCI as per routine study site clinical practice. Study data were collected from patient medical records and a routine visit 4 years after PCI. NCT02099565. Rate of MACCEs 4 years after PCI. Overall, 543 patients agreed to participate in the study (90.2% of patients in the original OPTIMA study). The mean (± standard deviation [SD]) duration of follow-up from the date of PCI to data collection was 4.42 ± 0.58 (range: 0.28-5.56) years. The frequency of MACCEs (including data in patients who died) was 30.8% (95% confidence interval: 27.0-34.7); half of MACCEs occurred in the first year of follow-up. After PCI, the majority of patients had no clinical signs of angina. Overall, 24.3% of patients discontinued statin intake in the 4 years after PCI. Only 7.7% of patients achieved a low-density lipoprotein (LDL) cholesterol goal of <1.8 mmol/L. Key limitations of this study related to its observational nature; for example, the sample size was small, the clinical results were derived from outpatients and hospitalized medical records, only one follow-up visit was performed at the end of the study (after 4 years' follow-up), only depersonalized medical information was made available for statistical analysis, and adherence to statin treatment was evaluated on the basis of patient questionnaire. Long-term follow-up of patients who underwent PCI with DES implantation demonstrated MACCEs in nearly one-third of patients, which is comparable to data from other studies. PCI was associated with relief from angina or minimal angina frequency, but compliance with statin therapy and the achievement of LDL cholesterol targets 4 years after PCI were suboptimal.
Mechanical Properties of High Entropy Alloy Al0.1CoCrFeNi for Peripheral Vascular Stent Application.
Alagarsamy, Karthik; Fortier, Aleksandra; Komarasamy, Mageshwari; Kumar, Nilesh; Mohammad, Atif; Banerjee, Subhash; Han, Hai-Chao; Mishra, Rajiv S
2016-12-01
High entropy alloys (HEAs) are new class of metallic materials with five or more principal alloying elements. Due to this distinct concept of alloying, the HEAs exhibit unique properties compared to conventional alloys. The outstanding properties of HEAs include increased strength, superior wear resistance, high temperature stability, increased fatigue properties, good corrosion, and oxidation resistance. Such characteristics of HEAs have generated significant interest among the scientific community. However, their applications are yet to be explored. This paper discusses the mechanical behavior and microstructure of Al 0.1 CoCrFeNi HEA subjected to thermo-mechanical processing, and its potential application in peripheral vascular stent implants that are prone to high failure rates. Results show that Al 0.1 CoCrFeNi alloy possesses characteristics that compare well against currently used stent materials and it can potentially find use in peripheral vascular stent implants and extend their life-cycle.
[Self-expandable metallic biliary endoprosthesis in malignant obstructive jaundice].
Güitrón-Cantú, Alfredo; Adalid-Martínez, Raúl; Gutiérrez-Bermúdez, José A
2005-01-01
Implantation of metallic stents for malignant biliary strictures has been recognized to be effective alternatives. To show our experience in metallic stents for palliation of malignant biliary strictures. Seventy three patients (38 males, 35 females, mean age 64.26) with malignant biliary strictures have been treated by implantation of metallic stents. Causes of obstruction were pancreatic carcinoma (23/73, 31.5%), bile duct carcinoma (31/73, 42.5%), carcinoma of ampula of Vater (11/73, 15%) and Klatskin tumor (3/73, 4.1%). Endoscopic procedure was successful in all cases. Neither procedure-related morbidity nor mortality was observed. Life surviving curve was 9 months and showed significant difference (p < 0.0071) in patients with carcinoma of ampula of Vater. Self-expanding metal endoprosthesis is a recognized method of palliation in malignant biliary obstruction. It efficiently relieves jaundice and generally improves comfort and nutritional status during the patient's remaining lifetime. The metallic stents are advantageous in patients surviving 6 months or less.
[Migration of a stent implanted in the pulmonary artery of a patient with tetralogy of Fallot].
Palomero Rodríguez, M A; Gabaldón Rivilla, M; Cabestrero Alonso, D; Gonzalez Cibrián, C; Abelleira Pardeiro, C; Centella Hernánez, T; Collado Gutierrez, R; Asuero de Lis, M S; Gómez González, R
2014-05-01
Tetralogy of Fallot is a congenital heart disease that accounts for 11-13% of the congenital cardiomyopathies. Stenosis and hyperplasia of the pulmonary arteries occur in a high proportion of them as this disease causes a native stenosis of the pulmonary branch, which can be surgically repaired with a stent. The use of balloon expandable intravascular stents is an alternative technique to further surgery in patients with congenital heart diseases. However, despite the gradual increase in their use, the limited number of procedures, combined with the wide anatomical variability and different characteristics of these patients, even in expert hands, stent implants are associated with a not inconsiderable incidence of complications. These are not always obvious and often require performing surgery in patients who have already had multiple interventions, thus increasing the complexity and the risk. Copyright © 2013 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Published by Elsevier España. All rights reserved.
Ohlow, Marc-Alexander; Farah, Ahmed; Richter, Stefan; El-Garhy, Mohamad; von Korn, Hubertus; Lauer, Bernward
2017-07-01
In a number of coronary bifurcation lesions, both the main vessel and the side branch (SB) need stent coverage. To analyze the procedural performance and the impact on radiation times (RT) and contrast medium consumption (CMC) of the Axxess™ stent system (Biosensors, Switzerland) treating de novo bifurcation lesions (DBL). One hundred and ten consecutive prospectively enrolled cases (Axxess Group) and 110 age, sex, and lesion location matched controls undergoing mandatory (Group A, n = 56) or provisional (Group B, n = 54) SB intervention were analyzed. Although more pre-dilatation was performed in the Axxess Group (92.7% vs. 46.4% [Group A] vs. 24.1% [Group B]), and more stents were used (2.4 vs. 1.2 vs. 1.05), RT and CMC were significantly lower in the Axxess Group [7.9 min/129 ml vs. 14.2 min/209 ml vs. 7.8 min/152 ml; P < 0.001]. Final Thrombolysis In Myocardial Infarction three flow in both branches was significantly more frequent in the Axxess Group (98.2% vs. 94.6% vs. 88.9%; P = 0.02), and post-interventional troponin T elevations were the lowest in the Axxess Group. Eighty one percent of the Axxess-stents could be implanted without technical difficulties. Difficult implantations procedures were mainly related to coronary anatomy. There was no safety concerns (cardiac death, stent-thrombosis) compared to controls. Cumulative 6-months MACE rates were 11% versus 23% versus 25%. TLR rates at 6-months were 5%, 18%, and 15%, respectively. Axxess bifurcation stent system procedures were associated with significantly less RT and CMC compared to conventional DBL therapy strategies. Difficult coronary anatomy may hinder successful implantation and a learning curve has to be considered. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
[Acetylsalicylic acid desensitization in the new era of percutaneous coronary intervention].
Fuertes Ferre, Georgina; Ferrer Gracia, Maria Cruz; Calvo Cebollero, Isabel
2015-09-21
Dual antiplatelet therapy is essential in patients undergoing percutaneous coronary intervention with stent implantation. Hypersensitivity to acetylsalicylic acid (ASA) limits treatment options. Desensitization to ASA has classically been studied in patients with respiratory tract disease. Over the last years, many protocols have been described about ASA desensitization in patients with ischemic heart disease, including acute coronary syndrome and the need for coronary stent implantation. It is important to know the efficacy and safety of ASA desensitization in these patients. Copyright © 2014 Elsevier España, S.L.U. All rights reserved.
Seth, A; Mathur, A; Chandra, P; Aggarwal, P; Khanna, N
1999-01-01
We report an interesting case with bilateral PTFE aorto-renal grafts of which one graft underwent balloon angioplasty and stenting for proximal stenosis. Combined debulking by AngioJet thrombectomy and Simpsons directional atherectomy was performed within the stent following reocclusion of the graft 9 months later.
Debus, Eike S; Kölbel, Tilo; Duprée, Anna; Daum, Günter; Sandhu, Harleen K; Manzoni, Daniel; Wipper, Sabine H
2018-02-01
The hybrid SPIDER-graft consists of a proximal descending aortic stent graft and a conventional six branched Dacron graft for open abdominal aortic repair. Technical feasibility with regard to avoiding thoracotomy and extracorporeal circulation (ECC) during thoraco-abdominal aortic hybrid repair and peri-procedural safety of this novel device are unknown. This was a feasibility and safety study in domestic pigs (75-85 kg). The abdominal aorta including iliac bifurcation, left renal artery, and visceral arteries were exposed via retroperitoneal access. The right iliac branch was first temporarily anastomosed end to side to the distal aorta via partial clamping. During inflow reduction and infra-coeliac cross-clamping, the coeliac trunk (CT) was divided and the proximal stent graft portion of the SPIDER-graft was deployed into the descending aorta via the CT ostium. Retrograde visceral and antegrade aorto-iliac blood flow was maintained via the iliac side branch. The visceral, renal, and iliac arteries were sequentially anastomosed, finally replacing the first iliac end to side anastomosis. Technical success, blood flow, periods of ischaemia, and peri-procedural complications were evaluated after intra-operative completion angiography and post-operative computed tomography angiography. Six animals underwent successful thoracic stent graft deployment and distal open reconstruction without peri-operative death. The median thoracic graft implantation time was 4.5 min, and the median ischaemia times before reperfusion were 10 min for the CT, 8 min for the superior mesenteric artery, 13 min for the right renal artery, and 22 min for the left renal artery. Angiography demonstrated appropriate graft implantation and blood flow measurements confirmed sufficient blood flow through all side branches. In this translational pig model, thoraco-abdominal hybrid repair using the novel SPIDER-graft was successful in avoiding thoracotomy and ECC. Technical feasibility and safety appear promising, but need to be reassessed in humans. Copyright © 2017. Published by Elsevier Ltd.
Acute rupture of the descending thoracic aorta: repair with use of endovascular stent-grafts.
Semba, C P; Kato, N; Kee, S T; Lee, G K; Mitchell, R S; Miller, D C; Dake, M D
1997-01-01
To describe the use of endovascular stent-grafts to treat acute ruptures of the descending thoracic aorta as an alternative to surgery in high-risk patients. From July 1992 to August 1996, 95 patients underwent stent-grafting of the descending thoracic aorta for a variety of lesions. Of these, 11 patients with acute (< or = 7 days) rupture from aneurysms (n = 8) or trauma (n = 3) underwent repair with use of endovascular stent-grafts. Rupture was confirmed with preoperative imaging studies and occurred in the mediastinum (n = 9), the pleural space (n = 1), or the lung (n = 1). All patients were considered high surgical risk due to generalized cardiopulmonary disease and/or previous thoracotomies. Stent-grafts were constructed from Z stents covered with polyester fabric and delivered through a catheter under fluoroscopic control from a remote access site. Stent-graft deployment was successful in all patients. There were no complications of perigraft leak, stent migration, paraplegia, or intraoperative death. Two patients died in the follow-up period: one of ventricular perforation during unrelated thoracic surgery for tumor resection (day 1) and one of cardiac arrest (day 28). All others are alive (mean follow-up, 15.1 months). For acute rupture of the thoracic aorta, endovascular stent-graft repair is technically feasible and may be a therapeutic alternative to a surgical interposition graft in patients considered high risk for conventional thoracotomy. Long-term studies are necessary to determine the role of stent-grafts in preventing future aortic rupture.
Gurvitch, R; Wood, D A; Tay, E L; Leipsic, J; Ye, J; Lichtenstein, S V; Thompson, C R; Carere, R G; Wijesinghe, N; Nietlispach, F; Boone, R H; Lauck, S; Cheung, A; Webb, J G
2010-09-28
Although short- and medium-term outcomes after transcatheter aortic valve implantation are encouraging, long-term data on valve function and clinical outcomes are limited. Consecutive high-risk patients who had been declined as surgical candidates because of comorbidities but who underwent successful transcatheter aortic valve implantation with a balloon-expandable valve between January 2005 and December 2006 and survived past 30 days were assessed. Clinical, echocardiographic, and computed tomographic follow-up examinations were performed. Seventy patients who underwent successful procedures and survived longer than 30 days were evaluated at a minimum follow-up of 3 years. At a median follow-up of 3.7 years (interquartile range 3.4 to 4.3 years), survival was 57%. Survival at 1, 2, and 3 years was 81%, 74%, and 61%, respectively. Freedom from reoperation was 98.5% (1 patient with endocarditis). During this early procedural experience, 11 patients died within 30 days, and 8 procedures were unsuccessful. When these patients were included, overall survival was 51%. Transaortic pressure gradients increased from 10.0 mm Hg (interquartile range 8.0 to 12.0 mm Hg) immediately after the procedure to 12.1 mm Hg (interquartile range 8.6 to 16.0 mm Hg) after 3 years (P=0.03). Bioprosthetic valve area decreased from a mean of 1.7±0.4 cm(2) after the procedure to 1.4±0.3 cm(2) after 3 years (P<0.01). Aortic incompetence after implantation was trivial or mild in 84% of cases and remained unchanged or improved over time. There were no cases of structural valvular deterioration, stent fracture, deformation, or valve migration. Transcatheter aortic valve implantation demonstrates good medium- to long-term durability and preserved hemodynamic function, with no evidence of structural failure. The procedure appears to offer an adequate and lasting resolution of aortic stenosis in selected patients.
The numerical simulation study of hemodynamics of the new dense-mesh stent
NASA Astrophysics Data System (ADS)
Ma, Jiali; Yuan, Zhishan; Yu, Xuebao; Feng, Zhaowei; Miao, Weidong; Xu, Xueli; Li, Juntao
2017-09-01
The treatment of aortic aneurysm in new dense mesh stent is based on the principle of hemodynamic changes. But the mechanism is not yet very clear. This paper analyzed and calculated the hemodynamic situation before and after the new dense mesh stent implanting by the method of numerical simulation. The results show the dense mesh stent changed and impacted the blood flow in the aortic aneurysm. The changes include significant decrement of blood velocity, pressure and shear forces, while ensuring blood can supply branches, which means the new dense mesh stent's hemodynamic mechanism in the treatment of aortic aneurysm is clearer. It has very important significance in developing new dense mesh stent in order to cure aortic aneurysm.
Suzuki, Takayuki; Siddiqui, Ali; Taylor, Linda J; Cox, Kristen; Hasan, Raza A; Laique, Sobia N; Mathew, Arun; Wrobel, Piotr; Adler, Douglas G
2016-01-01
Esophageal stents are commonly used to treat benign esophageal conditions including refractory benign esophageal strictures, anastomotic strictures, fistulae, perforations and anastomotic leaks. Data on outcomes in these settings remain limited. We performed a retrospective multicenter study of patients who underwent fully or partially covered self-expandable stent placement for benign esophageal diseases. Esophageal stent placements were performed for the following indications: (1) benign refractory esophageal strictures, (2) surgical anastomotic strictures, (3) esophageal perforations, (4) esophageal fistulae, and (5) surgical anastomotic leaks. A total of 70 patients underwent esophageal stent placement for benign esophageal conditions. A total of 114 separate procedures were performed. The most common indication for esophageal stent placement was refractory benign esophageal stricture (48.2%). Global treatment success rate was 55.7%. Treatment success rate was 33.3% in refractory benign strictures, 23.1% in anastomotic strictures, 100% in perforations, 71.4% in fistulae, and 80% in anastomotic leaks. Stent migration was noted in 28 of 70 patients (40%), most commonly seen in refractory benign strictures. This is one of the largest studies to date of esophageal stents to treat benign esophageal diseases. Success rates are lowest in benign esophageal strictures. These patients have few other options beyond chronic dilations, feeding tubes, and surgery, and fully covered self-expandable metallic stent give patients a chance to have their problem fixed endoscopically and still eat by mouth. Perforations, fistulas, and leaks respond very well to esophageal stenting, and stenting should be considered as a first-line therapy in these settings.
Bacterial characteristics and clinical significance of ureteral double-J stents in children.
García-Aparicio, L; Blázquez-Gómez, E; Martin, O; Krauel, L; de Haro, I; Rodó, J
2015-01-01
To determine the incidence of urinary tract infection in those patients that we have used an ureteral double-J stent as internal diversion after urological procedures. We reviewed all the medical records of patients who had a ureteral double-J stent after a urological procedure from August 2007 to May 2013. We have analyzed the following data: age, gender, type of prophylaxis, incidence of urinary tract infection (UTI), days of internal diversion with double-J stent, surgical procedure, bacterial characteristics, bacterial sensibility to antibiotics and UTI treatment. We have used 73 double-J stents as ureteral internal diversion in 67 patients with a mean age of 44.73±57.23. Surgical procedures were 50 laparoscopic Anderson-Hynes pyeloplasties in 49 patients, and 20 high-pressure balloon dilatation of the ureterovesical junction to treat primary obstructive megaureter in 15 patients; and 3 patients with ureterovesical obstruction after endoscopic treatment of vesicoureteral reflux. Forty three stents showed a bacterial colonization in cultures. Pseudomona aeruginosa was present in 9 (20.9%) stents. Only in 12 stents, bacterial colonization was sensible to antibiotic prophylaxis. Stent colonization was higher in boys and younger patients. Four patients had a febrile UTI. Incidence of UTI in younger patients that underwent HBPD of UVJ is higher. Bacterial colonization is frequent in double-J stents but the incidence of UTI is low. Double-J colonization is higher in younger patients. Patients that underwent HPBD have a higher risk of UTI related with ureteral double J stent. Copyright © 2014 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.
Molina, Wilson R; Pessoa, Rodrigo; Donalisio da Silva, Rodrigo; Kenny, McCabe C; Gustafson, Diedra; Nogueira, Leticia; Leo, Mark E; Yu, Michael K; Kim, Fernando J
2017-01-01
Approximately 12% of all ureteral stents placed are retained or "forgotten." Forgotten stents are associated with significant safety concerns as well as increased costs and legal issues. Retained ureteral stents (RUS) often occur due to lack of clinical follow-up, communication or language barriers, and economic concerns. We describe a multiplatform application that facilitates data collection to prevent RUS. The "Stent Tracker" application can be installed on mobile devices and computers. The encrypted and password-protected information is accessible from any device and provides information about each procedure, stent placement and removal dates, as well as product description. This multicenter retrospective study included 194 patients who underwent stent placement between July and October 2015. Nominal data was tallied and ordinal data was divided into quartiles of 25, 50, and 75%. A total of 194 patients from three institutions underwent ureteral stent placement. Reasons for stent placement include 122 cases post ureteroscopy (63%), 8 cases post percutaneous nephrolithotomy (PCNL) (4%), 14 cases post extracorporeal shock wave lithotripsy (SWL) (7%), 18 cases of cancer-related ureteral obstruction (9%), 21 cases of hydronephrosis (11%), and 11 for other reasons (6%). Of these patients, only one patient was lost to follow-up (0.5%). On average, ureteral stents were removed within 14 days of placement (IQR: 8-26 days). The "Stent Tracker" is a patient safety application that provides a secure and simplified interface, which can significantly reduce the incidence of RUS. Further developments could include automated notifications to patients and staff, color-coding, and integrated information with electronic patient charts.
Urolume stent placement for the treatment of postbrachytherapy bladder outlet obstruction.
Konety, B R; Phelan, M W; O'Donnell, W F; Antiles, L; Chancellor, M B
2000-05-01
Transurethral resection (TURP) or incision of the prostate is generally not effective for treating bladder outlet obstruction after transperineal brachytherapy for prostate cancer. Furthermore, TURP could compromise full-dose effective radiation delivery to the prostate. We analyzed the efficacy of the UroLume stent in treating the urinary outflow obstruction in such patients. Five patients who had undergone brachytherapy (3 with (192)Ir high-dose radiation and 2 with (125)I) subsequently developed one or more episodes of urinary retention 2 weeks to 4 years after treatment. The patients failed or could not tolerate alpha-blockers or clean intermittent catheterization. Three patients subsequently underwent urethral dilation/optical internal urethrotomy for strictures, and 1 patient underwent suprapubic tube placement. Following the failure of these interventions, each of these patients had a UroLume stent placement. A single UroLume stent (2 cm in 3 patients and 2.5 cm in 2 patients) was placed under local/spinal anesthesia. All patients were able to void spontaneously immediately after stent placement. Of the patients with previous urethral strictures, 1 remained continent and 1 had persistent incontinence. Neither of the patients with early postbrachytherapy retention developed incontinence after stent placement. The main complaints following stent placement were referred pain to the head of the penis and dysuria. Stent-related symptoms necessitated stent removal in 2 of 5 patients, 4 to 6 weeks after placement. The UroLume stent can be used as an alternative form of therapy for managing postbrachytherapy bladder outlet obstruction. The treatment is easily reversible by removing the stent when obstruction resolves.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yun, Jong Hyouk, E-mail: xell1015@naver.com; Jung, Gyoo-Sik, E-mail: gsjung@medimail.co.kr; Park, Jung Gu
PurposeTo evaluate the technical feasibility and clinical efficacy of placement of a newly designed Y-shaped branched covered stent for palliative treatment of malignant hilar biliary obstruction.MethodsFrom June 2011 to September 2014, 34 consecutive patients with malignant hilar biliary obstruction underwent percutaneous placement of a Y-shaped branched covered stent for palliative treatment. Technical and clinical success, complications, cumulative patient survival, and stent patency were evaluated.ResultsStent placement was technically successful in all patients. All patients showed adequate biliary drainage on the follow-up cholangiogram. Mean serum bilirubin level (10.9 mg/dl) decreased significantly 1 week (5.7 mg/dl) and 1 month (2.6 mg/dl) after stent placement (p < 0.01). Complications associated withmore » the procedure included hemobilia (n = 3) and biloma (n = 1). During the mean follow-up period of 225 (range 12–820) days, nine patients (26.5 %) developed stent occlusion caused by tumor overgrowth (n = 8) and sludge (n = 1). Two of them underwent coaxial placement of a second stent with good results. The median survival time was 281 days and median primary stent patency was 337 days. There were no significant differences in the patient survival and stent patency rates in relation to age, sex, or Bismuth type.ConclusionPercutaneous placement of the Y-shaped branched covered stent seems to be technically feasible and clinically effective for palliative treatment of malignant hilar biliary obstruction.« less
Nasa, Mukesh; Sharma, Zubin Dev; Choudhary, Narendra S; Puri, Rajesh; Sud, Randhir
2016-03-01
Esophageal rupture, spontaneous or iatrogenic, is associated with significant morbidity and mortality. The current study aims at highlighting the various clinical scenarios, where esophageal fully covered self-expanding removable metal stents (FCSEMS) can be used in esophageal rupture. In patients who underwent insertion of FCSEMS between January 2013 and June 2014, all data regarding demographics, indications, insertion, removal, and outcomes were studied retrospectively. Seven patients underwent the placement of esophageal covered SEMS. Two patients had Boerhaave syndrome, two had leak following the repair of aortic aneurysm, one had extensive esophageal injury following transesophageal echocardiography, one had carcinoma esophagus with tracheaesophageal fistula, and one had dehiscence of esophagogastric anastomosis. Stent insertion was successful in all the patients; one had stent migration which was managed endoscopically. Two patients died due to underlying illness; the rest had successful removal of stents after 8-10 weeks and good outcomes. Esophageal FCSEMS placement is safe and effective modality in management of patients with esophageal rupture.
Lausberg, Henning F; Gryszkiewicz, Rafal; Kuetting, Maximilian; Baumgaertner, Moritz; Centola, Marcos; Wendel, Hans-Peter; Nowak-Machen, Martina; Schibilsky, David; Kruger, Tobias; Schlensak, Christian
2017-07-01
Moderate or severe degree tricuspid valve regurgitation (TVR) is associated with high rates of morbidity and mortality. Surgical correction as the only therapeutic option offers unsatisfactory results. Recently, several interventional procedures have been introduced clinically in a limited cohort. We present our initial experiments with an innovative interventional valved stent graft for treatment of TVR. A newly designed porcine pericardium-covered nitinol stent graft with a lateral bicuspid valve was adapted to size in a cadaver study. After haemodynamic testing in an ex vivo perfusion setup, vascular access, valve delivery and function were investigated in an ovine animal model ( n = 7). The device was implanted successfully in all animals. Vascular access was established surgically via the femoral vein without any vascular complications. Angiography demonstrated the correct position of the device with proper sealing of both venae cavae in 6 animals. In 1 extremely large animal, the position of the device was considered too cranial but still acceptable. Correct valve function was verified in all animals by both angiography and echocardiography. There were no persistent arrhythmias other than during valve implant. All animals survived the implant procedure and were sacrificed electively. This study demonstrated that this new valved stent graft could be delivered safely with correct positioning and valve function in this ovine model. Further long-term studies in animals implanted with the device after creation of tricuspid regurgitation are necessary to prove the haemodynamic benefit of this procedure. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
NASA Astrophysics Data System (ADS)
Ughi, Giovanni J.; Adriaenssens, Tom; Larsson, Matilda; Dubois, Christophe; Sinnaeve, Peter; Coosemans, Mark; Desmet, Walter; D'hooghe, Jan
2012-01-01
In the last decade a large number of new intracoronary devices (i.e. drug-eluting stents, DES) have been developed to reduce the risks related to bare metal stent (BMS) implantation. The use of this new generation of DES has been shown to substantially reduce, compared with BMS, the occurrence of restenosis and recurrent ischemia that would necessitate a second revascularization procedure. Nevertheless, safety issues on the use of DES persist and full understanding of mechanisms of adverse clinical events is still a matter of concern and debate. Intravascular Optical Coherence Tomography (IV-OCT) is an imaging technique able to visualize the microstructure of blood vessels with an axial resolution <20 μm. Due to its very high spatial resolution, it enables detailed in-vivo assessment of implanted devices and vessel wall. Currently, the aim of several major clinical trials is to observe and quantify the vessel response to DES implantation over time. However, image analysis is currently performed manually and corresponding images, belonging to different IV-OCT acquisitions, can only be matched through a very labor intensive and subjective procedure. The aim of this study is to develop and validate a new methodology for the automatic registration of IV-OCT datasets on an image level. Hereto, we propose a landmark based rigid registration method exploiting the metallic stent framework as a feature. Such a tool would provide a better understanding of the behavior of different intracoronary devices in-vivo, giving unique insights about vessel pathophysiology and performance of new generation of intracoronary devices and different drugs.
Wijayarathna, S; Suvendran, S; Ishak, M; Weligamage, A; Epa, A; Munasinghe, S; Abeygunaskera, A M
2014-12-01
We investigated the outcome of endoscopic retrograde ureteric stenting (RUS) in patients with ureteric obstruction related to malignant lesions. Data were prospectively collected from patients with ureteric obstruction related to malignant lesions treated at a single urology unit from 1 January 2011 to 30 April 2014. All patients had radiologically significant hydronephrosis by ultrasonography and CT scanning. First choice of urinary drainage was placing a retrograde ureteric stent cystoscopically. Outcome of patients who had stenting were recorded after following them until death or removal of stents. Eighty two patients with ureteric obstruction related to malignant lesions had complete data. In 33 (25%) patients, retrograde ureteric stenting was possible. Fifteen of them had recurrent tumour in the pelvis at the time of stenting and 13 (87%) were dead within 3 months of stenting. Four of the five patients who did not have pelvic tumour recurrence were alive at the end of the study. All eight patients who underwent stenting before surgery as a prophylactic measure and three of the five patients who had retroperitoneal tumour mass and underwent RUS were alive. Stenting was not possible in 42 patients. Thirty eight of them had pelvic tumour recurrences and two were having retroperitoneal tumour masses. Only one did not have tumour in the pelvis.CT evidence of tumour recurrence in the pelvis (OR 12.7; 95% CI 1.3-117.6; p=0.026) and high serum creatinine (OR 4.3; 95% CI 1.6-11.7; p=0.004) were associated with failure to ureteric stenting. Chances of successful RUS were low in patients with ureteric obstruction in the presence of tumour recurrences or elevated serum creatinine. Even if ureteric stenting was successful, their life expectancy was short.
Pavia, Philippa R; Berent, Allyson C; Weisse, Chick W; Neiman, Dana; Lamb, Kenneth; Bagley, Demetrius
2018-03-15
OBJECTIVE To describe the technique and short- and long-term outcomes for dogs undergoing double-pigtail ureteral stent placement for treatment of benign ureteral obstruction. DESIGN Retrospective case series. ANIMALS 44 dogs (57 ureters). PROCEDURES Medical records of dogs that underwent ureteral stenting for treatment of benign ureteral obstruction between 2010 and 2013 were reviewed. Signal-ment, history, pertinent diagnostic imaging results, endourologic and post-procedural details, duration of hospitalization, complications, and outcome (short term, 7 to 30 days; long term, > 30 days) were recorded. Ureteral stent placement was performed endoscopically, surgically, or both, with fluoroscopic guidance. RESULTS 57 ureters (44 dogs) underwent stenting because of obstructive ureterolithiasis (n = 48 [84%]), stricture (5 [9%]), or both (4 [7%]). Endoscopic or surgical techniques were successful for stent placement in 45 of 55 and 12 of 12 ureters (34/42 and 10/10 dogs), respectively. Median hospitalization time was 1 day. Median creatinine concentration was 2 mg/dL prior to stenting and 1.3 mg/dL 3 months after the procedure. Urinary tract infections were present in 26 of 44 (59%) dogs prior to stenting and in 11 of 43 dogs (26%) after stenting. One of the 44 (2%) dogs died after undergoing stenting, but the cause of death was not related to the procedure. Median follow-up time was 1,158 days (range, 3 to > 1,555 days), with 30 of 44 dogs alive at the time of last follow-up. CONCLUSIONS AND CLINICAL RELEVANCE Results suggested that ureteral stenting may be a viable option for first-line treatment of dogs with benign ureteral obstruction. However, patients should be monitored for urinary tract infection following stenting.
Long-term surveillance of zinc implant in murine artery: Surprisingly steady biocorrosion rate.
Drelich, Adam J; Zhao, Shan; Guillory, Roger J; Drelich, Jaroslaw W; Goldman, Jeremy
2017-08-01
Metallic zinc implanted into the abdominal aorta of rats out to 6months has been demonstrated to degrade while avoiding responses commonly associated with the restenosis of vascular implants. However, major questions remain regarding whether a zinc implant would ultimately passivate through the production of stable corrosion products or via a cell mediated fibrous encapsulation process that prevents the diffusion of critical reactants and products at the metal surface. Here, we have conducted clinically relevant long term in vivo studies in order to characterize late stage zinc implant biocorrosion behavior and products to address these critical questions. We found that zinc wires implanted in the murine artery exhibit steady corrosion without local toxicity for up to at least 20months post-implantation, despite a steady buildup of passivating corrosion products and intense fibrous encapsulation of the wire. Although fibrous encapsulation was not able to prevent continued implant corrosion, it may be related to the reduced chronic inflammation observed between 10 and 20months post-implantation. X-ray elemental and infrared spectroscopy analyses confirmed zinc oxide, zinc carbonate, and zinc phosphate as the main components of corrosion products surrounding the Zn implant. These products coincide with stable phases concluded from Pourbaix diagrams of a physiological solution and in vitro electrochemical impedance tests. The results support earlier predictions that zinc stents could become successfully bio-integrated into the arterial environment and safely degrade within a time frame of approximately 1-2years. Previous studies have shown zinc to be a promising candidate material for bioresorbable endovascular stenting applications. An outstanding question, however, is whether a zinc implant would ultimately passivate through the production of stable corrosion products or via a cell mediated tissue encapsulation process that prevented the diffusion of critical reactants and products at the metal surface. We found that zinc wires implanted in the murine artery exhibit steady corrosion for up to at least 20months post-implantation. The results confirm earlier predictions that zinc stents could safely degrade within a time frame of approximately 1-2years. Copyright © 2017 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Oh, Pyung Chun; Suh, Soon Yong; Kang, Woong Chol; Lee, Kyounghoon; Han, Seung Hwan; Ahn, Taehoon; Shin, Eak Kyun
2016-01-01
Background/Aims: Treatment of coronary in-stent restenosis (ISR) is still associated with a high incidence of recurrence. We aimed to compare the efficacy and safety of drug-eluting balloons (DEB) for the treatment of ISR as compared with conventional balloon angioplasty (BA) and drug-eluting stents (DES). Methods: Between January 2006 and May 2012 a total of 177 patients (188 lesions, 64.1 ± 11.7 years old) who underwent percutaneous coronary intervention for ISR were retrospectively enrolled. Clinical outcomes were compared between patients treated with DEB (n = 58, 32.8%), conventional BA (n = 65, 36.7%), or DES (n = 54, 30.5%). The primary end point was a major adverse cardiac event (MACE), defined as a composite of cardiac death, myocardial infarction, and target lesion revascularization(TLR). Results: Baseline characteristics were not different except for a history of previous MI, which was more frequent in patients treated by conventional BA or DES than in patients treated by DEB (40.0% vs. 48.1% vs. 17.2%, respectively, p = 0.002). The total incidences of MACEs were 10.7%, 7.4%, and 15.4% in patients treated by DEB, DES, or conventional BA, respectively (p > 0.05). TLR was more frequent in patients treated by conventional BA than in patients treated by DEB or DES, but this was not statistically significant (10.8% vs. 6.9% vs. 3.7%, p > 0.05 between all group pairs, respectively). Conclusions: This study showed that percutaneous coronary intervention using DEB might be a feasible alternative to conventional BA or DES implantation for treatment of coronary ISR. Further large-scaled, randomized study assessing long-term clinical and angiographic outcomes will be needed. PMID:26951915
Bornapour, M; Muja, N; Shum-Tim, D; Cerruti, M; Pekguleryuz, M
2013-02-01
Magnesium is an attractive material for use in biodegradable implants due to its low density, non-toxicity and mechanical properties similar to those of human tissue such as bone. Its biocompatibility makes it amenable for use in a wide range of applications from bone to cardiovascular implants. Here we investigated the corrosion rate in simulated body fluid (SBF) of a series of Mg-Sr alloys, with Sr in the range of 0.3-2.5%, and found that the Mg-0.5 Sr alloy showed the slowest corrosion rate. The degradation rate from this alloy indicated that the daily Sr intake from a typical stent would be 0.01-0.02 mg day⁻¹, which is well below the maximum daily Sr intake levels of 4 mg day⁻¹. Indirect cytotoxicity assays using human umbilical vascular endothelial cells indicated that Mg-0.5 Sr extraction medium did not cause any toxicity or detrimental effect on the viability of the cells. Finally, a tubular Mg-0.5 Sr stent sample, along with a WE43 control stent, was implanted into the right and left dog femoral artery. No thrombosis effect was observed in the Mg-0.5 Sr stent after 3 weeks of implantation while the WE43 stent thrombosed. X-ray diffraction demonstrated the formation of hydroxyapatite and Mg(OH)₂ as a result of the degradation of Mg-0.5 Sr alloy after 3 days in SBF. X-ray photoelectron spectroscopy further showed the possibility of the formation of a hydroxyapatite Sr-substituted layer that presents as a thin layer at the interface between the Mg-0.5 Sr alloy and the corrosion products. We believe that this interfacial layer stabilizes the surface of the Mg-0.5 Sr alloy, and slows down its degradation rate over time. Copyright © 2012 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
[Percutaneously implantable aortic valve: the JenaValve concept evolution].
Figulla, Hans R; Ferrari, Markus
2006-10-01
Due to the increasing incidence of severe aortic stenosis in old and multimorbid patients, the percutaneous implantation of aortic valve-carrying stents has become an alternative to the surgical replacement of aortic valves. Starting in 1995, the authors developed a self-expanding stent which transferred the necessary forces for anchoring up to the aorta ascendens-a conception taken over from CoreValve. The further improvement of this idea over the past 11 years has led to a self-expanding, relatively short stent-valve system that is reliably positioned in the cusps of the old aortic valve and holds the old valve like a paper clip, thus transferring the holding forces physiologically. As compared to conventional systems, the sophisticated insertion catheter requires further chronic animal tests so as to represent a true alternative to the conventional surgical procedure.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Strecker, Ernst-Peter; Gabelmann, Andreas; Boos, Irene
1998-11-15
Purpose: Polymer-coated, dexamethasone (DXM)-releasing stents were tested in order to assess the efficacy of DXM released locally for the prevention of stent restenosis due to intimal hyperplasia. Methods: Strecker stents coated with a biodegradable membrane containing DXM were implanted percutaneously into the femoral artery in 14 dogs. The contralateral artery received a conventional non-coated stent serving as control. The drugs are eluted by degradation of the carrier membrane. Follow-up intraarterial digital subtraction angiography (DSA) was obtained at 3, 6, 9, 12, and 24 weeks with subsequent autopsy. Specimens for gross and microscopic pathology were obtained and histomorphometry was performed. Results:more » Four of 14 DXM-coated stents showed thrombotic occlusion within the first 3 weeks; ten DXM-coated stents remained patent. At follow-up DSA, DXM-coated stents showed a significantly wider lumen than the non-coated stents. At morphometry there was less intimal hyperplasia over DXM-coated stents than over non-coated stents (p < 0.05). Conclusion: DXM-coated stents reduce neointimal hyperplasia in dogs when compared with non-coated stents.« less
[Finite Element Analysis of Intravascular Stent Based on ANSYS Software].
Shi, Gengqiang; Song, Xiaobing
2015-10-01
This paper adopted UG8.0 to bulid the stent and blood vessel models. The models were then imported into the finite element analysis software ANSYS. The simulation results of ANSYS software showed that after endothelial stent implantation, the velocity of the blood was slow and the fluctuation of velocity was small, which meant the flow was relatively stable. When blood flowed through the endothelial stent, the pressure gradually became smaller, and the range of the pressure was not wide. The endothelial shear stress basically unchanged. In general, it can be concluded that the endothelial stents have little impact on the flow of blood and can fully realize its function.
Use of a wire extender during neuroprotected vertebral artery angioplasty and stenting.
Lesley, Walter S; Kumar, Ravi; Rangaswamy, Rajesh
2010-09-01
The off-label use of an extender wire during vertebral artery stenting and angioplasty with or with neuroprotection has not been previously reported. Retrospective, single-patient, technical report. After monorail balloon angioplasty was performed on a proximal left vertebral artery stenosis, the 190 cm long Accunet neuroprotection filter device was not long enough for delivery of an over-the-wire stent. After mating a 145 cm long, 0.014 inch extension wire to the filter device, a balloon-mounted Liberté stent was implanted with good angiographic and clinical results. The off-label use of an extender wire permits successful over-the-wire stenting on a monorail neuroprotection device for vertebral artery endosurgery.
Endoscopic Removal of a Nitinol Mesh Stent from the Ureteropelvic Junction after 15 Years
Smrkolj, Tomaž; Šalinović, Domagoj
2015-01-01
We report a rare case of a patient with a large stone encrusted on a nitinol mesh stent in the ureteropelvic junction. The stent was inserted in the year 2000 after failure of two pyeloplasty procedures performed due to symptomatic ureteropelvic junction stenosis. By combining minimally invasive urinary stone therapies—extracorporeal shock wave lithotripsy, semirigid ureterorenoscopy with laser lithotripsy, and percutaneous nephrolithotomy—it was possible to completely remove the encrusted stone and nitinol mesh stent that was implanted for 15 years, rendering the patient symptom and obstruction free. PMID:26697258
Interaction of intraluminal tissue and coronary sinus lead stabilized with stent placement.
Balázs, Tibor; Merkely, Béla; Bognár, Eszter; Zima, Endre
2013-04-01
The aim of our investigation was to examine the intraluminal interaction of the vascular tissue and the implanted coronary sinus lead stabilized with stent on two human hearts removed before transplantation. The coronary sinus lumen was sectioned under operational microscope and opened carefully. The leads and stents were found separately positioned beside each other completely covered by an intact intimal tissue layer. No sign of occluding proliferative tissue was observed. Stent fixation technique and extraction of the CS lead in our cases did not have any particular damaging effect on the vascular system. © 2012 Wiley Periodicals, Inc.
Dias-Neto, Marina; Matschuck, Manuela; Bausback, Yvonne; Banning-Eichenseher, Ursula; Steiner, Sabine; Branzan, Daniela; Staab, Holger; Varcoe, Ramon L; Scheinert, Dierk; Schmidt, Andrej
2018-06-01
To report midterm results of the "pave-and-crack" technique to facilitate safe and effective scaffolding of heavily calcified femoropopliteal lesions in preparation for delivery of a Supera interwoven stent. Data were collected retrospectively on 67 consecutive patients (mean age 71±8 years; 54 men) treated with this technique between November 2011 and February 2017 at a single center. A third (22/64, 34%) of the patients had critical limb ischemia (CLI). Most lesions were TASC D (52/67, 78%), and the majority were occlusions (61/66, 92%). The mean lesion length was 26.9±11.2 cm. Nearly two-thirds (40/64, 62%) had grade 4 calcification (Peripheral Arterial Calcium Scoring System). To prepare for Supera stenting, the most heavily calcified segments of the lesion were predilated aggressively to obliterate recoil. A Viabahn stent-graft was then implanted to "pave" the lesion and protect from vessel rupture as aggressive predilation continued until the calcified plaque was "cracked" before lining the entire lesion with a Supera stent. Patency and target lesion revascularization (TLR) rates were estimated using the Kaplan-Meier method. Procedural success was achieved in 100% and technical success (residual stenosis <30%) in 98% (66/67). The mean cumulative stent lengths were 16±9 cm for the Viabahn and 23±12 cm for the Supera. Only 2 complications occurred (distal embolization and access-site pseudoaneurysm). Two CLI patients died within 30 days, and 3 patients (all claudicants) underwent a TLR. Patients were followed for a mean 19±18 months, during which another 2 CLI patients died and 1 patient had a major amputation. One-year primary and secondary patency estimates were 79% and 91%, respectively; freedom from TLR was 85%. Despite severe lesion calcification, patients experienced high technical success and a safe and durable therapy at midterm follow-up with the femoropopliteal "pave-and-crack" technique.
Chow, Po-Ming; Hsu, Jui-Shan; Huang, Chao-Yuan; Wang, Shuo-Meng; Lee, Yuan-Ju; Huang, Kuo-How; Yu, Hong-Jheng; Pu, Yeong-Shiau; Liang, Po-Chin
2014-06-01
To provide clinical outcomes of the Resonance metallic ureteral stent in patients with malignant ureteral obstruction, as well as clinical factors predicting stent failure. Cancer patients who have received Resonance stents from July 2009 to March 2012 for ureteral obstruction were included for chart review. Stent failure was detected by clinical symptoms, image studies, and renal function tests. Survival analysis for stent duration was used to estimate patency rate and factors predicting stent failure. A total of 117 stents were inserted successfully into 94 ureteral units in 79 patients. There were no major complications. These stents underwent survival analysis and proportional hazard regression. The median duration for the stents was 5.77 months. In multivariate analysis, age (P=0.043), preoperative serum creatinine level (P=0.0174), and cancer type (P=0.0494) were significant factors associated with stent failure. Cancer treatment before and after stent insertion had no effect on stent duration. Resonance stents are effective and safe in relieving malignant ureteral obstructions. Old age and high serum creatinine level are predictors for stent failure. Stents in patients with lower gastrointestinal cancers have longer functional duration.
Behaviour of two typical stents towards a new stent evolution.
Simão, M; Ferreira, J M; Mora-Rodriguez, J; Fragata, J; Ramos, H M
2017-06-01
This study explores the analysis of a new stent geometry from two typical stents used to treat the coronary artery disease. Two different finite element methods are applied with different boundary conditions to investigate the stenosis region. Computational fluid dynamics (CFD) models including fluid-structure interaction are used to assess the haemodynamic impact of two types of coronary stents implantation: (1) type 1-based on a strut-link stent geometry and (2) type 2-a continuous helical stent. Using data from a recent clinical stenosis, flow disturbances and consequent shear stress alterations introduced by the stent treatment are investigated. A relationship between stenosis and the induced flow fields for the two types of stent designs is analysed as well as the correlation between haemodynamics and vessel wall biomechanical factors during the initiation and development of stenosis formation in the coronary artery. Both stents exhibit a good performance in reducing the obstruction artery. However, stent type 1 presents higher radial deformation than the type 2. This deformation can be seen as a limitation with a long-term clinical impact.
Henderson, Alastair; Laing, Robert W; Langley, Stephen E M
2002-01-01
Assessment of the Spanner, a new temporary urethral stent to relieve bladder outflow obstruction and urinary symptoms after brachytherapy. Five patients with unusually severe urinary morbidity after (125)I brachytherapy were recruited. The mean time after implant was 40 days (range 25-90). Spanner intraprostatic stents were introduced using topical anesthetic without complication. All patients were able to void spontaneously with no post-void residual volume of urine. The flow rates increased in all cases (p=0.03) and the International Prostate Symptom Scores were significantly improved after stent insertion in all patients (p=0.03). All patients experienced some degree of pain or dysuria during stent use. Bladder outflow obstruction was effectively treated with the Spanner intraprostatic stent, however pain limited the use of the device in the early post-brachytherapy patient group. Pharmacotherapy, stent design modification, or smaller stent diameter may increase the utility of stents after brachytherapy.
Endovascular Broad-Neck Aneurysm Creation in a Porcine Model Using a Vascular Plug
DOE Office of Scientific and Technical Information (OSTI.GOV)
Muehlenbruch, Georg, E-mail: gmuehlenbruch@ukaachen.de; Nikoubashman, Omid; Steffen, Bjoern
2013-02-15
Ruptured cerebral arterial aneurysms require prompt treatment by either surgical clipping or endovascular coiling. Training for these sophisticated endovascular procedures is essential and ideally performed in animals before their use in humans. Simulators and established animal models have shown drawbacks with respect to degree of reality, size of the animal model and aneurysm, or time and effort needed for aneurysm creation. We therefore aimed to establish a realistic and readily available aneurysm model. Five anticoagulated domestic pigs underwent endovascular intervention through right femoral access. A total of 12 broad-neck aneurysms were created in the carotid, subclavian, and renal arteries usingmore » the Amplatzer vascular plug. With dedicated vessel selection, cubic, tubular, and side-branch aneurysms could be created. Three of the 12 implanted occluders, two of them implanted over a side branch of the main vessel, did not induce complete vessel occlusion. However, all aneurysms remained free of intraluminal thrombus formation and were available for embolization training during a surveillance period of 6 h. Two aneurysms underwent successful exemplary treatment: one was stent-assisted, and one was performed with conventional endovascular coil embolization. The new porcine aneurysm model proved to be a straightforward approach that offers a wide range of training and scientific applications that might help further improve endovascular coil embolization therapy in patients with cerebral aneurysms.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Doros, Attila, E-mail: dorattila@yahoo.com; Nemeth, Andrea; Deak, Akos Pal
The role of covered stent in the management of biliary complications is not yet defined in liver transplant recipients. This Case Report presents a patient with anastomotic stricture and leakage with biloma treated with a covered stent 32 months following liver transplantation. Signs of in-stent restenosis developed 52 months following covered stent placement, which was resolved by balloon dilation. There were no complications during the interventions. The latest follow-up, at 69 months following primary and 19 months following secondary percutaneous intervention, shows a patent covered stent without any clinical or morphological sign of further restenosis. The clinical success with long-termmore » follow-up data suggests that covered stent implantation can be a rational, minimally invasive option for simultaneous treatment of bile duct stenosis and bile leak following liver transplantation in selected cases.« less
Mao, Lin; Shen, Li; Chen, Jiahui; Wu, Yu; Kwak, Minsuk; Lu, Yao; Xue, Qiong; Pei, Jia; Zhang, Lei; Yuan, Guangyin; Fan, Rong; Ge, Junbo; Ding, Wenjiang
2015-03-11
Magnesium (Mg) alloys have revolutionized the application of temporary load-bearing implants as they meet both engineering and medical requirements. However, rapid degradation of Mg alloys under physiological conditions remains the major obstacle hindering the wider use of Mg-based implants. Here we developed a simple method of preparing a nanoscale MgF2 film on Mg-Nd-Zn-Zr (denoted as JDBM) alloy, aiming to reduce the corrosion rate as well as improve the biological response. The corrosion rate of JDBM alloy exposed to artificial plasma is reduced by ∼20% from 0.337 ± 0.021 to 0.269 ± 0.043 mm·y(-1) due to the protective effect of the MgF2 film with a uniform and dense physical structure. The in vitro cytocompatibility test of MgF2-coated JDBM using human umbilical vein endothelial cells indicates enhanced viability, growth, and proliferation as compared to the naked substrate, and the MgF2 film with a nanoscale flakelike feature of ∼200-300 nm presents a much more favorable environment for endothelial cell adhesion, proliferation, and alignment. Furthermore, the animal experiment via implantation of MgF2-coated JDBM stent to rabbit abdominal aorta confirms excellent tissue compatibility of the well re-endothelialized stent with no sign of thrombogenesis and restenosis in the stented vessel.
Cheung, Nicholas K; Chiu, Albert Hy; Cheung, Andrew; Wenderoth, Jason D
2018-06-01
Stent assisted coil embolization (SACE) of bifurcation aneurysms is challenging. Heterogeneous results have been achieved to date, but largely for laser cut stents. While braided stents offer multiple technical advantages, their long term efficacy has yet to be validated. To report the first long term 18 month results for the durability of bifurcation aneurysms treated with braided stents. Over a 4 year period, 59 consecutive patients with 60 bifurcation aneurysms underwent elective braided SACE across three Australian neurovascular centers. 17 of these aneurysms underwent T- or Y-shaped stent constructs. All patients had immediate, 6 month and 18 month clinical and radiological follow-up. Radiological assessment was made on modified Raymond-Roy occlusion scores while clinical assessment was based on the modified Rankin Scale. Subgroup analysis of 17 aneurysms treated with multi-stent constructs was conducted. 6 month follow-up data were available for 59 aneurysms and 18 month follow-up data for 58 aneurysms. Satisfactory aneurysm occlusion was achieved in 97% at inception and at 6 months, and 98% at 18 months. Good neurological outcomes were achieved in 95% at 18 months. Similar satisfactory results were achieved with the multi-stent construct cohort. Intraprocedural thromboembolic events were recorded in 5% and delayed events in 2%. Technical complications were found in 5%. All complication rate was 13%. Braided SACE was safe, efficacious, and durable at the long term 18 month follow-up, including for multi-stent constructs. Preliminary results indicate favorable clinical and radiological outcomes compared with laser cut stents. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yoon, Jehong; Kwon, Se Hwan, E-mail: Kwon98@khu.ac.kr; Lee, Chang-Kyun
PurposeTo evaluate the safety, feasibility, and patency rates of radiologic placement of uncovered stents for the treatment of malignant colonic obstruction proximal to the descending colon.Materials and MethodsThis was a retrospective, single-center study. From May 2003 to March 2015, 53 image-guided placements of uncovered stents (44 initial placements, 9 secondary placements) were attempted in 44 patients (male:female = 23:21; mean age, 71.8 years). The technical and clinical success, complication rates, and patency rates of the stents were also evaluated. Technical success was defined as the successful deployment of the stent under fluoroscopic guidance alone and clinical success was defined as the relief of obstructivemore » symptoms or signs within 48 h of stent deployment.ResultsIn total, 12 (27.3 %) patients underwent preoperative decompression, while 32 (72.7 %) underwent decompression with palliative intent. The technical success rate was 93.2 % (41/44) for initial placement and 88.9 % (8/9) for secondary placement. Secondary stent placement in the palliative group was required in nine patients after successful initial stent placement due to stent obstruction from tumor ingrowth (n = 7) and stent migration (n = 2). The symptoms of obstruction were relieved in all successful cases (100 %). In the palliative group, the patency rates were 94.4 % at 1 month, 84.0 % at 3 months, 64.8 % at 6 months, and 48.6 % at 12 months.ConclusionsThe radiologic placement of uncovered stents for the treatment of malignant obstruction proximal to the descending colon is feasible and safe, and provides acceptable clinical results.« less
Superficial Femoral Artery Intervention by Single Transpedal Arterial Access.
Amoroso, Nicholas S; Shah, Sooraj; Liou, Michael; Ratcliffe, Justin; Lala, Moinakhtar; Diwan, Ravi; Huang, Yili; Rosero, Hugo; Coppola, John; Bertrand, Olivier F; Kwan, Tak W
2015-11-01
Atherosclerotic disease of the superficial femoral artery (SFA) is frequently seen and can be treated with percutaneous interventions, traditionally via femoral artery access. There are limited reports of transpedal artery access for peripheral artery interventions, but none to date describing routine primary transpedal artery approach for SFA stenting. In this preliminary study, we report 4 patients who underwent successful endovascular SFA stenting using a single transpedal artery access via a new ultra-low profile 6 Fr sheath (Glidesheath Slender; Terumo Corporation). All patients underwent successful SFA stenting without complication. Procedure time varied from 51 to 72 minutes. The mean contrast amount used was 56 mL; mean fluoroscopy time was 21 minutes; mean radiation dose was 91 mGy. At 1-month follow-up, duplex ultrasonography showed that all pedal arteries had remained patent. Transpedal artery approach as a primary approach to SFA stenting appears feasible and safe. Comparative trials with standard percutaneous femoral approach are warranted.
Imaging vascular implants with optical coherence tomography
NASA Astrophysics Data System (ADS)
Barton, Jennifer K.; Dal Ponte, Donny B.; Williams, Stuart K.; Ford, Bridget K.; Descour, Michael R.
2000-04-01
Vascular stents and grafts have many proven and promising clinical applications, but also a large number of complications. A focus of current research is the development of biocompatible implants. Evaluation of these devices generally requires a large number of animals due to the need for explanation and histological evaluation of the implant at several time intervals. It would be desirable to use instead a high resolution, in situ assessment method. An in vitro study was performed to determine if OCT could image cell proliferation and thrombus formation on vascular stents and grafts. First, images were taken of explanted stents. The implants were locate din peripheral vessels of a porcine model of atherosclerosis. The images clearly show the vessel response to initial damage, the materials of the implant, extent of intimal cell hyper proliferation, and small platelet aggregates. Next, a tissue engineered graft, which had been sodded with smooth muscle cells and incubated in a bioreactor, was evaluated. Cross-section images showed the pores of the polymer material and the layer of smooth muscle cells beginning to invade the graft material. For comparison, in vitro 20 MHz IVUS images of the same grafts were obtained. A catheter was designed for intravascular imaging. The 2.3 mm diameter catheter contains a fiber with GRIN lens and right angle prism, a monorail guidewire, and a novel positioning wire that can be protruded to push the catheter against the vessel wall, potentially eliminating the need for saline flush. Preliminary in vitro results with this catheter are encouraging.
Vassalli, Giuseppe; Klersy, Catherine; De Servi, Stefano; Galatius, Soeren; Erne, Paul; Eberli, Franz; Rickli, Hans; Hornig, Burkhard; Bertel, Osmund; Bonetti, Piero; Moccetti, Tiziano; Kaiser, Christoph; Pfisterer, Matthias; Pedrazzini, Giovanni
2016-03-01
The randomized BASKET-PROVE study showed no significant differences between sirolimus-eluting stents (SES), everolimus-eluting stents (EES), and bare-metal stents (BMS) with respect to the primary end point, rates of death from cardiac causes, or myocardial infarction (MI) at 2 years of follow-up, in patients requiring stenting of a large coronary artery. Clinical risk factors may affect clinical outcomes after percutaneous coronary interventions. We present a retrospective analysis of the BASKET-PROVE data addressing the question as to whether the optimal type of stent can be predicted based on a cumulative clinical risk score. A total of 2,314 patients (mean age 66 years) who underwent coronary angioplasty and implantation of ≥1 stents that were ≥3.0 mm in diameter were randomly assigned to receive SES, EES, or BMS. A cumulative clinical risk score was derived using a Cox model that included age, gender, cardiovascular risk factors (hypercholesterolemia, hypertension, family history of cardiovascular disease, diabetes, smoking), presence of ≥2 comorbidities (stroke, peripheral artery disease, chronic kidney disease, chronic rheumatic disease), a history of MI or coronary revascularization, and clinical presentation (stable angina, unstable angina, ST-segment elevation MI). An aggregate drug-eluting stent (DES) group (n = 1,549) comprising 775 patients receiving SES and 774 patients receiving EES was compared to 765 patients receiving BMS. Rates of death from cardiac causes or nonfatal MI at 2 years of follow-up were significantly increased in patients who were in the high tertile of risk stratification for the clinical risk score compared to those who were in the aggregate low-mid tertiles. In patients with a high clinical risk score, rates of death from cardiac causes or nonfatal MI were lower in patients receiving DES (2.4 per 100 person-years, 95% CI 1.6-3.6) compared with BMS (5.5 per 100 person-years, 95% CI 3.7-8.2, hazard ratio 0.45, 95% CI 0.26-0.80, P = .007). However, they were not significantly different between receivers of DES and BMS in patients in the low-mid risk tertiles. This exploratory analysis suggests that, in patients who require stenting of a large coronary artery, use of a clinical risk score may identify those patients for whom DES use may confer a clinical advantage over BMS, beyond lower restenosis rates. Copyright © 2015 Elsevier Inc. All rights reserved.
Rotational atherectomy ablation for an unexpandable stent under the guide of IVUS
Si, Daoyuan; Liu, Guohui; Tong, Yaliang; He, Yuquan
2018-01-01
Abstract Rationale: Inadequate stent expansion due to rigid calcified may result in restenosis lesions, but the available options are limited. Patient concerns: We report a case via the trans-radial approach of the severely underexpanded freshly deployed stent due to heavily calcified plaques Diagnoses: Coronary angiography revealed that there was no adequate expansion of the freshly deployed stent. Interventions: Under the guide of intravascular ultrasound (IVUS), rotational atherectomy (RA) successfully ablated the stent layers and the protruding calcified plaque. Followed by balloon angioplasty, the ablated segment was scaffolded with another stent, well expanded and documented by IVUS. Outcomes: The patient was uneventful during the procedure and remained angina free at the point of one year of clinical follow-up. Lessons: This case indicated that RA via the trans-radial approach could be a useful remedy in the situation of under-expansion of implanted stents, and the debulking should be performed under IVUS-guidance. PMID:29443790
Cabrera, María Sol; Oomens, Cees W J; Baaijens, Frank P T
2017-04-01
A proper interpretation of the forces developed during stent crimping and deployment is of paramount importance for a better understanding of the requirements for successful heart valve replacement. The present study combines experimental and computational methods to assess the performance of a nitinol stent for tissue-engineered heart valve implantation. To validate the stent model, the mechanical response to parallel plate compression and radial crimping was evaluated experimentally. Finite element simulations showed good agreement with the experimental findings. The computational models were further used to determine the hoop force on the stent and radial force on a rigid tool during crimping and self-expansion. In addition, stent deployment against ovine and human pulmonary arteries was simulated to determine the hoop force on the stent-artery system and the equilibrium diameter for different degrees of oversizing. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.
Jurado-Román, Alfonso; Rubio-Alonso, Belén; García-Tejada, Julio; Sánchez-Pérez, Ignacio; López-Lluva, María T; Gómez-Blázquez, Iván; Velázquez-Martín, María T; Albarrán-González-Trevilla, Agustín; Hernández-Hernández, Felipe; Lozano-Ruíz-Poveda, Fernando
2017-10-26
To analyse systematic isolated post-dilatation of the side branch as a part of provisional stent technique. 1960 angioplasties performed in two centres were prospectively registered, of which 382 were coronary bifurcations with a side branch>2mm. In centre A, isolated post-dilatation of the side branch was performed regardless its impairment after main vessel stenting. In centre B, side branch post-dilatation was performed only if it was severely affected after stent implantation. There was no difference between the two centres in the rate of side branch affection after stent implantation (A: 44.6 vs B: 49.3%, p=0.48) nor in the procedural success rate (A: 98.6% vs B: 96.7%, p=0.45). After one-year follow-up, a reduction of cardiovascular events was observed in centre A (A: 4.4% vs B: 10.4%, p=0.043) with a trend towards lower cardiac mortality (A: 2.2% vs B: 6.5%, p=0.093) and stent thrombosis (A: 0% vs B: 2.6%, p=0.077). There were no differences in the rate of myocardial infarction related to the treated artery (A: 1.4% vs B: 3.9%, p=0.29), or target lesion revascularization (A: 1.4% vs. B: 3.2%, p=0.45). Systematic isolated post-dilatation of the side branch in the provisional stent technique was associated with a high angiographic success rate, and a low rate of cardiovascular events during follow-up. Although the study design does not allow definitive conclusions, this strategy could be considered a valid option in some cases or even as part of the provisional stent technique. Copyright © 2017 Elsevier Inc. All rights reserved.
Lee, Joo Myung; Cho, Deok-Kyu; Hahn, Joo-Yong; Song, Young Bin; Park, Taek Kyu; Oh, Ju-Hyeon; Lee, Jin Bae; Doh, Joon-Hyung; Kim, Sang-Hyun; Yang, Jeong Hoon; Choi, Jin-Ho; Choi, Seung-Hyuck; Lee, Sang Hoon; Gwon, Hyeon-Cheol
2016-12-01
Dual antiplatelet therapy (DAPT) is a fundamental treatment that optimizes clinical outcomes after percutaneous coronary intervention, especially in patients with acute coronary syndrome (ACS). Although current international guidelines recommend DAPT for at least 12 months after implantation of a drug-eluting stent in patients with ACS, these recommendations are not based on randomized controlled trials dedicated to ACS population. The SMART-DATE trial is a prospective, multicenter, randomized, and open-label study to demonstrate the noninferiority of 6-month DAPT compared with 12 months or longer DAPT in patients with ACS undergoing percutaneous coronary intervention. A total of 2,700 patients will undergo prospective, random assignment to either of the DAPT duration groups. To minimize the bias from different stent devices, the type of stents will be randomly assigned (everolimus-eluting stents, zotarolimus-eluting stents, or biolimus A9-eluting stents). The primary end point is a composite of all-cause death, myocardial infarction, and cerebrovascular events at 18 months after the index procedure. The major secondary end points are definite/probable stent thrombosis defined by the Academic Research Consortium and bleeding defined by Bleeding Academic Research Consortium type 2-5. The SMART-DATE randomized trial is the first study exploring the safety of 6-month DAPT compared with conventional 12-month or longer DAPT dedicated to patients with ACS after second-generation drug-eluting stent implantation. Copyright © 2016 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lanciego, Carlos; Rodriguez, Mario; Rodriguez, Adela
The use of metallic stents in the management of benign and malignant superior vena cava syndrome (SVCS) is well documented. Symptomatic stenosis or occlusion of the SVC is a rare complication of a transvenous permanent pacemaker implant. Suggested treatments have included anticoagulation therapy, thrombolysis, balloon angioplasty and surgery. More recently, endovascular stenting has evolved as an attractive alternative but the data available in the literature are limited. We describe a case in which venous stenting with a Wallstent endoprosthesis was used successfully. The patient remains symptom free and with normal pacemaker function 36 months later.
Rigatelli, Gianluca; Avvocata, Fabio Dell'; Ronco, Federico; Giordan, Massimo; Roncon, Loris; Caprioglio, Francesco; Grassi, Giuseppe; Faggian, Giuseppe; Cardaioli, Paolo
2016-06-01
Implantation of Drug Eluting Stents (DES) plus bioresorbable scaffolds (BVS) in very long diffuse left anterior descending coronary artery (LAD) disease may be problematic because of multiple devices overlapping. We sought to assess the short and mid-tern outcomes of combined implantation of DES and BVS using a novel "edge-to-edge" technique in patients with diffuse LAD disease. Patients with long diffuse LAD disease were enrolled in a prospective registry from 1st August 2014 to 1st August 2015 and treated with IVUS-aided percutaneous coronary intervention using a DES plus a single or multiple BVS using a novel "edge-to-edge" technique. Clinical follow up and invasive follow up driven by clinical justification was performed. Twenty-three patients (5 females, mean age 59.1± 9.1 years) were enrolled. Mean length of LAD disease was 73.1 ± 20.6 mm. Mean number of DES and BVS implanted was 1.2 ± 0.4 and 1.7 ± 1.3, respectively. At a mean follow-up of 11.3 ± 3.8 months, no stent thrombosis or MACE were observed. Angiographic and IVUS follow-up at a mean of 6.6 ± 0.7 months showed no significant angiographic restenosis and no appreciable stent gaps. In revascularization of long diffuse disease of the LAD, the edge-to-edge implantation technique appears to be feasible resulting in no restenosis or thrombosis on the short-term follow-up. (J Interven Cardiol 2016;29:275-284). © 2016, Wiley Periodicals, Inc.
Uthamaraj, Susheil; Tefft, Brandon J; Jana, Soumen; Hlinomaz, Ota; Kalra, Manju; Lerman, Amir; Dragomir-Daescu, Dan; Sandhu, Gurpreet S
2016-10-26
Stent-grafts are widely used for the treatment of various conditions such as aortic lesions, aneurysms, emboli due to coronary intervention procedures and perforations in vasculature. Such stent-grafts are manufactured by covering a stent with a polymer membrane. An ideal stent-graft should have a biocompatible stent covered by a porous, thromboresistant, and biocompatible polymer membrane which mimics the extracellular matrix thereby promoting injury site healing. The goal of this protocol is to manufacture a small caliber stent-graft by encapsulating a balloon expandable stent within two layers of electrospun polyurethane nanofibers. Electrospinning of polyurethane has been shown to assist in healing by mimicking native extracellular matrix, thereby promoting endothelialization. Electrospinning polyurethane nanofibers on a slowly rotating mandrel enabled us to precisely control the thickness of the nanofibrous membrane, which is essential to achieve a small caliber balloon expandable stent-graft. Mechanical validation by crimping and expansion of the stent-graft has shown that the nanofibrous polyurethane membrane is sufficiently flexible to crimp and expand while staying patent without showing any signs of tearing or delamination. Furthermore, stent-grafts fabricated using the methods described here are capable of being implanted using a coronary intervention procedure using standard size guide catheters.
Conformability of balloon-expandable stents to the carotid siphon: an in vitro study.
du Mesnil de Rochemont, R; Yan, B; Zanella, F E; Rüfenacht, D A; Berkefeld, J
2006-02-01
Endovascular placement of coronary balloon-expandable stents in patients with recurrent cerebral ischemia has emerged as a treatment option for intracranial arterial occlusive disease. We have developed an in vitro model matching the tortuous curve of the carotid siphon that allows the assessment of apposition of stents to a curved vessel wall. Six types of balloon-expandable coronary stents were implanted in a silicone model of the carotid siphon. Digital radiographs and 3D rotational angiograms were obtained. Stent morphology was evaluated and the degree of apposition between stent and wall of the model was measured on a digital workstation. All 6 stents showed lack of apposition between stent and the wall at the convexity of the anterior segment of the carotid siphon and the wall at the concavity at both extremities of the stent. In and around the curve, the modules of the stents did not expand completely to their nominal diameter and were distorted to an oval shape. The tested coronary balloon-expandable stents did not completely conform to the vessel wall of the model of the carotid siphon and further development is needed to approach the goal of an "ideal intracranial stent."
Werner, Gerald S; Ahmed, Waqar H
2017-09-01
Covered stents are indicated for coronary perforations, but they may seal off major side branches in that process. We report the successful sealing of an ostial left main perforation, induced by a guide catheter in the course of a retrograde approach to treat a chronic total occlusion (CTO) of the right coronary artery (RCA) in a 76year old woman with prior CABG. The implanted Papyrus covered stent, however, overlapped the left main bifurcation and occluded the non-grafted circumflex artery (CX) resulting in acute ischemia. Through a double lumen catheter advanced over the wire located in the left anterior descending coronary artery (LAD) territory, a stiff recanalization wire could be advanced from the side-port to penetrate the stent membrane towards the CX. This was successfully achieved, and after subsequent dilatation, a drug-eluting stent was implanted in Culotte-fashion from the CX to the left main with subsequent kissing-balloon dilatation. The clinical symptoms subsided immediately, and the RCA was finally recanalized in antegrade parallel wire technique. No periprocedural infarct was observed during 48h of follow-up before discharge. At clinical follow-up of 6months the patient is symptom-free. Copyright © 2017 Elsevier Inc. All rights reserved.
Zhang, Qi; Wang, Xiao Long; Liao, Min Lei; Hu, Jian; Yang, Zhen Kun; Ding, Feng Hua; Zhang, Jian Sheng; Du, Run; Zhu, Tian Qi; Shen, Wei Feng; Zhang, Rui Yan
2015-03-01
Patients are at risk of developing periprocedural myonecrosis after percutaneous coronary intervention (PCI). We investigated whether the use of the platelet glycoprotein (GP) IIb/IIIa receptor inhibitor tirofiban could reduce periprocedural myocardial infarction (PMI) in patients with stable coronary artery disease undergoing elective PCI with overlapping stent implantation for long lesions. A total of 748 stable angina patients with long lesions (≥ 40 mm in length) treated with overlapping stent implantation were randomly assigned to receive tirofiban (tirofiban group; n = 373) or conventional therapy (control group; n = 375). Intravenous tirofiban was initiated before PCI and maintained for 12 hr after the procedure. The primary endpoint was PMI, defined as an elevation in CK-MB > 3 times the upper limit of normal 12 hr after the index procedure. The secondary endpoint was major adverse cardiac events (MACE), including cardiac death, target vessel revascularization, and recurrent MI (re-MI), at one-year of clinical follow-up. The safety end-points included Thrombolysis in Myocardial Infarction (TIMI) major bleeding and stent thrombosis. Despite comparable angiographic and procedural characteristics, in the intention-to-treatment analysis, the primary endpoint was significantly reduced in the tirofiban group (4.0% vs. 11.5%, P < 0.001). Multivariate analysis revealed that the adjunctive use of tirofiban was the only negative predictor of PMI (OR 0.41, 95% CI 0.28-0.81, P < 0.01). At one-year of clinical follow-up, the overall occurrence of MACE was significantly lower in the tirofiban group (13.4% vs. 22.7%, P = 0.001). The rate of TIMI major bleeding and stent thrombosis did not differ significantly between the two groups. Our results show that the adjunctive use of tirofiban reduces the occurrence of PMI and MACE at one year in stable coronary artery disease patients undergoing elective PCI for long lesions with overlapping stent implantation. © 2015 Wiley Periodicals, Inc.
Krankenberg, Hans; Zeller, Thomas; Ingwersen, Maja; Schmalstieg, Josefin; Gissler, Hans Martin; Nikol, Sigrid; Baumgartner, Iris; Diehm, Nicolas; Nickling, Estell; Müller-Hülsbeck, Stefan; Schmiedel, Rainer; Torsello, Giovanni; Hochholzer, Willibald; Stelzner, Christian; Brechtel, Klaus; Ito, Wulf; Kickuth, Ralph; Blessing, Erwin; Thieme, Marcus; Nakonieczny, Jaroslaw; Nolte, Thomas; Gareis, Ragnar; Boden, Harald; Sixt, Sebastian
2017-08-28
Atherosclerosis of iliac arteries is widespread. As inflow vessels, they are of great clinical significance and increasingly being treated by endovascular means. Most commonly, stents are implanted. So far, due to a lack of comparative data, no guideline recommendations on the preferable stent type, balloon-expandable stent (BE) or self-expanding stent (SE), have been issued. In this randomized, multicenter study, patients with moderate to severe claudication from common or external iliac artery occlusive disease were assigned 1:1 to either BE or SE. The primary endpoint was binary restenosis at 12 months as determined by duplex ultrasound. Key secondary endpoints were walking impairment, freedom from target lesion revascularization (TLR), hemodynamic success, target limb amputation, and all-cause death. Six hundred sixty patients with 660 lesions were enrolled at 18 German and Swiss sites over a period of 34 months; 24.8% of the patients had diabetes and 57.4% were current smokers. The common iliac artery was affected in 58.9%. One hundred nine (16.5%) lesions were totally occluded and 25.6% heavily calcified. Twelve-month incidence of restenosis was 6.1% after SE implantation and 14.9% after BE implantation (p = 0.006). Kaplan-Meier estimate of freedom from TLR was 97.2% and 93.6%, respectively (p = 0.042). There was no between-group difference in walking impairment, hemodynamic success, amputation rate, all-cause death, or periprocedural complications. The treatment of iliac artery occlusive disease with SE as compared with BE resulted in a lower 12-month restenosis rate and a significantly reduced TLR rate. No safety concerns arose in both groups. (Iliac, Common and External [ICE] Artery Stent Trial; NCT01305174). Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Use of drug-eluting stents in Victorian public hospitals.
Yan, Bryan P; Ajani, Andrew E; Duffy, Stephen J; New, Gishel; Horrigan, Mark; Szto, Gregory; Walton, Antony; Eccleston, David; Lefkovits, Jeffery; Black, Alexander; Sebastian, Martin; Brennan, Angela L; Reid, Christopher M; Clark, David J
2006-10-02
We aimed to assess the pattern of use of drug-eluting stents (DESs) in patients undergoing percutaneous coronary interventions (PCIs) in Victorian public hospitals. Prospective study comparing the use of one or more DESs versus bare-metal stents (BMSs) only, in consecutive patients undergoing 2428 PCIs with stent implantation from 1 April 2004 to 31 December 2005 at seven Victorian public hospitals. Adherence to current Victorian Department of Human Services guidelines which recommend DES use in patients with high-risk features for restenosis (diabetes, small vessels, long lesions, in-stent restenotic lesions, chronic total occlusions and bifurcation lesions). Of the 2428 PCIs performed, at least one DES was implanted in 1101 (45.3%) and BMSs only were implanted in 1327 (54.7%). In 87.7% (966/1101) of PCI with DESs, there was at least one criterion for high risk of restenosis. DESs were more likely to be used in patients with diabetes (risk ratio [RR], 2.45; 95% CI, 2.02-2.97), small vessels (RR, 3.35; 95%CI, 2.35-4.76), long lesions (RR, 3.87; 95% CI, 3.23-4.65), in-stent restenotic lesions (RR, 3.98; 95%CI, 2.67-6.06), chronic total occlusions (RR, 1.30; 95% CI, 0.51-2.88) and bifurcation lesions (RR, 2.23; 95%CI, 1.57-3.17). However, 66.2% (1608/2428) of all PCIs were in patients eligible for DESs according to Victorian guidelines, and in 39.9% (642/1608) of these PCIs, a BMS was used. In Victorian public hospitals, DESs have been largely reserved for patients at high risk of restenosis in accordance with Department of Human Services guidelines. However, many patients with high-risk criteria for restenosis did not receive DESs. Greater use of DESs in these patients may improve outcomes by reducing the need for repeat revascularisation.
Riaz, Usman; Rakesh, Leela; Shabib, Ishraq; Haider, Waseem
2018-06-05
The issue of long-term incompatible interactions associated with the permanent implants can be eliminated by using various biodegradable metal implants. The recent research is focusing on the use of degradable stents to restore most of the hindrances of capillaries, and coronary arteries by supplying instant blood flow with constant mechanical and structural support. However, internal endothelialization and infection due to the corrosion of implanted stents are not easy to diagnose in the long run. In the recent past, magnesium (Mg) has been widely investigated for the cardiovascular stent applications. Here we made an attempt to understand the biodegradation process of Mg alloy stent by studying the degradation of Mg alloy AZ31 (3 wt% Aluminum, 1 wt% Zn) powder at various time-intervals in simulated blood fluid using the Rheological methods. The degradability of the Mg stent in the arteries affects the stress-strain properties of blood plasma and the subsequent flow conditions. Blood and plasma viscosities alter due to the degradation of Mg resulting from the stress-strain experienced in the blood vessels, in which the stent is inserted. Here our objective was to explore the influence of Mg degradation on the blood plasma viscosity by studying the viscoelastic properties. In this work, the effect of dissolution of Mg alloy AZ31 on the rheological properties of Phosphate Buffer Saline (PBS) at various time intervals have been investigated. The viscosity of the PBS-AZ31 solution increased with the dissolution of both slurries and percolated clear solution. The only exception was day-7 of the percolated clear solution, where viscosity was decreased showing a reduction in viscosity at initial stages of dissolution. The frequency sweep showed the tendency of the PBS-AZ31 gelation up to 100 rad/s frequency. Copyright © 2018 Elsevier Ltd. All rights reserved.
Experimental Evaluation of a New Single Wire Stainless Steel Fishscale Coronary Stent (Freedomª).
Wang; Verbeken; Mukherjee; Zhou; De Scheerder IK
1996-10-01
Recent randomized clinical trials revealed a significant reduction in angiographic restenosis rates when adjunctive stenting was performed after conventional coronary balloon angioplasty. Current approved coronary stents are however hampered by their rigidity, limiting their trackability in tortuous vessels and furthermore, needing high pressure deployment for optimal vessel apposition. New coronary stents are currently under development, using more biocompatible metal alloys and/or designs which better align to the vessel wall at moderate deployment pressures. We evaluated the safety, efficacy, angiographic and histological effect of a new stainless steel fishscale designed stent (Freedomª, Global Therapeutics, Co., USA) in a porcine coronary and peripheral artery model. Implantation in the right coronary artery was successful in all 20 pigs. Control angiograms at 6 weeks follow-up demonstrated patent vessels and morphologic evaluation showed only a mild fibromuscular neointimal response resulting in an area stenosis of 28.7 +/- 0.18% and a mean neointimal hyperplasia of 0.18 +/- 0.25 mm. Comparison with the Palmaz-Schatzª coronary stent in a porcine peripheral artery model demonstrated similar quantitative angiographic and morphologic vessel analysis results. Also the morphometric data were comparable. Area stenosis: Palmaz-Schatz: 37 +/- 0.24%, Freedom: 21 +/- 0.14%, p = 0.07. Mean neointimal hyperplasia: Palmaz-Schatz: 0.33 +/- 0.24 mm, Freedom: 0.18 +/- 0.08 mm, p = 0.08. CONCLUSION: Freedom coronary stent implantation in a porcine model resulted in a high procedural success without subacute thrombotic occlusions, despite no further anticoagulation nor antiplatelet therapy. Six weeks histopathological and morphometric evaluation demonstrated only a mild fibromuscular neointimal hyperplasia.
Sensor to detect endothelialization on an active coronary stent
2010-01-01
Background A serious complication with drug-eluting coronary stents is late thrombosis, caused by exposed stent struts not covered by endothelial cells in the healing process. Real-time detection of this healing process could guide physicians for more individualized anti-platelet therapy. Here we present work towards developing a sensor to detect this healing process. Sensors on several stent struts could give information about the heterogeneity of healing across the stent. Methods A piezoelectric microcantilever was insulated with parylene and demonstrated as an endothelialization detector for incorporation within an active coronary stent. After initial characterization, endothelial cells were plated onto the cantilever surface. After they attached to the surface, they caused an increase in mass, and thus a decrease in the resonant frequencies of the cantilever. This shift was then detected electrically with an LCR meter. The self-sensing, self-actuating cantilever does not require an external, optical detection system, thus allowing for implanted applications. Results A cell density of 1300 cells/mm2 on the cantilever surface is detected. Conclusions We have developed a self-actuating, self-sensing device for detecting the presence of endothelial cells on a surface. The device is biocompatible and functions reliably in ionic liquids, making it appropriate for implantable applications. This sensor can be placed along the struts of a coronary stent to detect when the struts have been covered with a layer of endothelial cells and are no longer available surfaces for clot formation. Anti-platelet therapy can be adjusted in real-time with respect to a patient's level of healing and hemorrhaging risks. PMID:21050471
Urban, Philip; Abizaid, Alexandre; Banning, Adrian; Bartorelli, Antonio L; Baux, Ana Cebrian; Džavík, Vladimír; Ellis, Stephen; Gao, Runlin; Holmes, David; Jeong, Myung Ho; Legrand, Victor; Neumann, Franz-Josef; Nyakern, Maria; Spaulding, Christian; Worthley, Stephen
2011-03-29
The aim of this study was to ascertain the 1-year incidence of stent thrombosis (ST) and major bleeding (MB) in a large, unselected population treated with sirolimus-eluting stents (SES). Stent thrombosis and MB are major potential complications of drug-eluting stent implantation. Their relative incidence and predisposing factors among large populations treated worldwide are unclear. The SES were implanted in 15,147 patients who were entered in a multinational registry. We analyzed the incidence of: 1) definite and probable ST as defined by the Academic Research Consortium; and 2) MB, with the STEEPLE (Safety and efficacy of Enoxaparin in PCI) definition, together with their relation to dual antiplatelet therapy (DAPT) and to 1-year clinical outcomes. The mean age of the sample was 62 ± 11 years, 30.4% were diabetic, 10% had a Charlson comorbidity index ≥3, and 44% presented with acute coronary syndrome or myocardial infarction. At 1 year, the reported compliance with DAPT as recommended by the European Society of Cardiology guidelines was 86.3%. Adverse event rates were: ST 1.0%, MB 1.0%, mortality 1.7%, myocardial infarction 1.9%, and target lesion revascularization 2.3%. Multivariate analysis identified 9 correlates of ST and 4 correlates of MB. Advanced age and a high Charlson index were associated with an increased risk of both ST and MB. After ST, the 7-day and 1-year all-cause mortality was 30% and 35%, respectively, versus 1.5% and 10% after MB. Only 2 of 13,749 patients (0.015%) experienced both MB and ST during the entire 1-year follow-up period. In this worldwide population treated with ≥1 SES, the reported compliance with DAPT was good, and the incidence of ST and MB was low. Stent thrombosis and MB very rarely occurred in the same patient. (The e-SELECT Registry: a Multicenter Post-Market Surveillance; NCT00438919). Copyright © 2011 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Automatic three-dimensional registration of intravascular optical coherence tomography images
NASA Astrophysics Data System (ADS)
Ughi, Giovanni J.; Adriaenssens, Tom; Larsson, Matilda; Dubois, Christophe; Sinnaeve, Peter R.; Coosemans, Mark; Desmet, Walter; D'hooge, Jan
2012-02-01
Intravascular optical coherence tomography (IV-OCT) is a catheter-based high-resolution imaging technique able to visualize the inner wall of the coronary arteries and implanted devices in vivo with an axial resolution below 20 μm. IV-OCT is being used in several clinical trials aiming to quantify the vessel response to stent implantation over time. However, stent analysis is currently performed manually and corresponding images taken at different time points are matched through a very labor-intensive and subjective procedure. We present an automated method for the spatial registration of IV-OCT datasets. Stent struts are segmented through consecutive images and three-dimensional models of the stents are created for both datasets to be registered. The two models are initially roughly registered through an automatic initialization procedure and an iterative closest point algorithm is subsequently applied for a more precise registration. To correct for nonuniform rotational distortions (NURDs) and other potential acquisition artifacts, the registration is consecutively refined on a local level. The algorithm was first validated by using an in vitro experimental setup based on a polyvinyl-alcohol gel tubular phantom. Subsequently, an in vivo validation was obtained by exploiting stable vessel landmarks. The mean registration error in vitro was quantified to be 0.14 mm in the longitudinal axis and 7.3-deg mean rotation error. In vivo validation resulted in 0.23 mm in the longitudinal axis and 10.1-deg rotation error. These results indicate that the proposed methodology can be used for automatic registration of in vivo IV-OCT datasets. Such a tool will be indispensable for larger studies on vessel healing pathophysiology and reaction to stent implantation. As such, it will be valuable in testing the performance of new generations of intracoronary devices and new therapeutic drugs.