Sample records for undulator rf bpm

  1. Sub-micron resolution rf cavity beam position monitor system at the SACLA XFEL facility

    NASA Astrophysics Data System (ADS)

    Maesaka, H.; Ego, H.; Inoue, S.; Matsubara, S.; Ohshima, T.; Shintake, T.; Otake, Y.

    2012-12-01

    We have developed and constructed a C-band (4.760 GHz) rf cavity beam position monitor (RF-BPM) system for the XFEL facility at SPring-8, SACLA. The demanded position resolution of the RF-BPM is less than 1 μm, because an electron beam and x-rays must be overlapped within 4 μm precision in the undulator section for sufficient FEL interaction between the electrons and x-rays. In total, 57 RF-BPMs, including IQ demodulators and high-speed waveform digitizers for signal processing, were produced and installed into SACLA. We evaluated the position resolutions of 20 RF-BPMs in the undulator section by using a 7 GeV electron beam having a 0.1 nC bunch charge. The position resolution was measured to be less than 0.6 μm, which was sufficient for the XFEL lasing in the wavelength region of 0.1 nm, or shorter.

  2. Linac coherent light source (LCLS) undulator RF BPM system.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lill, R.; Waldschmidt, G.; Morrison, L.

    2006-01-01

    The Linac Coherent Light Source (LCLS) will be the world's first x-ray free-electron laser (FEL) when it becomes operational in 2009. The LCLS is currently in the construction phase. The beam position monitor (BPM) system planned for the LCLS undulator will incorporate a high-resolution X-band cavity BPM system described in this paper. The BPM system will provide high-resolution measurements of the electron beam trajectory on a pulse-to-pulse basis and over many shots. The X-band cavity BPM size, simple fabrication, and high resolution make it an ideal choice for LCLS beam position detection. We will discuss the system specifications, design, andmore » prototype test results.« less

  3. Linac Coherent Light Source Undulator RF BPM System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lill, R.M.; Morrison, L.H.; Waldschmidt, G.J.

    2007-04-17

    The Linac Coherent Light Source (LCLS) will be the world's first x-ray free-electron laser (FEL) when it becomes operational in 2009. The LCLS is currently in the construction phase. The beam position monitor (BPM) system planned for the LCLS undulator will incorporate a high-resolution X-band cavity BPM system described in this paper. The BPM system will provide high-resolution measurements of the electron beam trajectory on a pulse-to-pulse basis and over many shots. The X-band cavity BPM size, simple fabrication, and high resolution make it an ideal choice for LCLS beam position detection. We will discuss the system specifications, design, andmore » prototype test results.« less

  4. PAL-XFEL cavity beam position monitor pick-up design and beam test

    NASA Astrophysics Data System (ADS)

    Lee, Sojeong; Park, Young Jung; Kim, Changbum; Kim, Seung Hwan; Shin, Dong Cheol; Han, Jang-Hui; Ko, In Soo

    2016-08-01

    As an X-ray Free Electron Laser, PAL-XFEL is about to start beam commissioning. X-band cavity beam position monitor (BPM) is used in the PAL-XFEL undulator beam line. Prototypes of cavity BPM pick-up were designed and fabricated to test the RF characteristics. Also, the beam test of a cavity BPM pick-up was done in the Injector Test Facility (ITF). In the beam test, the raw signal properties of the cavity BPM pick-up were measured at a 200 pC bunch charge. According to the RF test and beam test results, the prototype cavity BPM pick-up design was confirmed to meet the requirements of the PAL-XFEL cavity BPM system.

  5. Fast Beam-Based BPM Calibration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bertsche, K.; Loos, H.; Nuhn, H.-D.

    2012-10-15

    The Alignment Diagnostic System (ADS) of the LCLS undulator system indicates that the 33 undulator quadrupoles have extremely high position stability over many weeks. However, beam trajectory straightness and lasing efficiency degrade more quickly than this. A lengthy Beam Based Alignment (BBA) procedure must be executed every two to four weeks to re-optimize the X-ray beam parameters. The undulator system includes RF cavity Beam Position Monitors (RFBPMs), several of which are utilized by an automatic feedback system to align the incoming electron-beam trajectory to the undulator axis. The beam trajectory straightness degradation has been traced to electronic drifts of themore » gain and offset of the BPMs used in the beam feedback system. To quickly recover the trajectory straightness, we have developed a fast beam-based procedure to recalibrate the BPMs. This procedure takes advantage of the high-precision monitoring capability of the ADS, which allows highly repeatable positioning of undulator quadrupoles. This report describes the ADS, the position stability of the LCLS undulator quadrupoles, and some results of the new recovery procedure.« less

  6. Resolution Studies at Beam Position Monitors at the FLASH Facility at DESY

    NASA Astrophysics Data System (ADS)

    Baboi, N.; Lund-Nielsen, J.; Noelle, D.; Riesch, W.; Traber, T.; Kruse, J.; Wendt, M.

    2006-11-01

    More than 60 beam position monitors (BPM) are installed along about 350m of beamline of the Free Electron LASer in Hamburg (FLASH) at DESY. The room-temperature part of the accelerator is equipped mainly with stripline position monitors. In the accelerating cryo-modules there are cavity and re-entrant cavity BPMs, which will not be discussed here. In the undulator part of the machine button BPMs are used. This area requires a single bunch resolution of 10μm. The electronics is based on the AM/PM normalization principle and is externally triggered. Single-bunch position is measured. This paper presents the methods used to determine the resolution of the BPMs. The results based on correlations between different BPMs along the machine are compared to noise measurements in the RF lab. The performance and difficulties with the BPM design and the current electronics as well as its development are discussed.

  7. Design and performance of the LCLS cavity BPM system.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lill, R.; Norum, E.; Morrison, L.

    2008-01-01

    In this paper we present the design of the beam position monitor (BPM) system for the LCLS undulator, which features a high-resolution X-band cavity BPM. Each BPM has a TM{sub 010} monopole reference cavity and a TM{sub 110} dipole cavity designed to operate at a center frequency of 11.384 GHz. The signal processing electronics features a low- noise single-stage three-channel heterodyne receiver that has selectable gain and a phase locking local oscillator. We will discuss the system specifications, design, and prototype test results.

  8. Design and Performance of the LCLS Cavity BPM System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lill, R.M.; Morrison, L.H.; Norum, W.E.

    2008-01-23

    In this paper we present the design of the beam position monitor (BPM) system for the LCLS undulator, which features a high-resolution X-band cavity BPM. Each BPM has a TM{sub 010} monopole reference cavity and a TM{sub 110} dipole cavity designed to operate at a center frequency of 11.384 GHz. The signal processing electronics features a low noise single-stage three-channel heterodyne receiver that has selectable gain and a phase locking local oscillator. We will discuss the system specifications, design, and prototype test results.

  9. Flying radio frequency undulator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kuzikov, S. V.; Vikharev, A. A.; Savilov, A. V.

    2014-07-21

    A concept for the room-temperature rf undulator, designed to produce coherent X-ray radiation by means of a relatively low-energy electron beam and pulsed mm-wavelength radiation, is proposed. The “flying” undulator is a high-power short rf pulse co-propagating together with a relativistic electron bunch in a helically corrugated waveguide. The electrons wiggle in the rf field of the −1st spatial harmonic with the phase velocity directed in the opposite direction in respect to the bunch velocity, so that particles can irradiate high-frequency Compton's photons. A high group velocity (close to the speed of light) ensures long cooperative motion of the particlesmore » and the co-propagating rf pulse.« less

  10. Development of BPM Electronics at the JLAB FEL

    NASA Astrophysics Data System (ADS)

    Sexton, D.; Evtushenko, P.; Jordan, K.; Yan, J.; Dutton, S.; Moore, W.; Evans, R.; Coleman, J.

    2006-11-01

    A new version of BPM electronics based on the AD8362 RMS detector, which is a direct RF to DC converter, is under development at the JLAB FEL. Each of these new BPM electronics utilizes an embedded ColdFire Microprocessor for data processing and communication with the EPICS control system via TCP/IP. The ColdFire runs RTEMS, which is an open source real-time operating system. The JLAB FEL is a SRF Energy Recovery LINAC capable of running up to 10 mA CW beam with a 74.85 MHz micropulse frequency. For diagnostic reasons and for machine tune up, the micropulse frequency can be reduced to 1.17 MHz, which corresponds to about 160 μA of beam current. It is required that the BPM system would be functional for all micropulse frequencies. By taking into account the headroom for the beam steering and current variations the dynamic range of the RF front end is required to be about 60 dB. A BPM resolution of at least 100 μm is required, whereas better resolution is very desirable to make it possible for more accurate measurements of the electron beam optics. Some results of the RF front end development are presented as well as the first measurements made with an electron beam.

  11. Development of BPM Electronics at the JLAB FEL

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sexton, D.; Evtushenko, P.; Jordan, K.

    2006-11-20

    A new version of BPM electronics based on the AD8362 RMS detector, which is a direct RF to DC converter, is under development at the JLAB FEL. Each of these new BPM electronics utilizes an embedded ColdFire Microprocessor for data processing and communication with the EPICS control system via TCP/IP. The ColdFire runs RTEMS, which is an open source real-time operating system. The JLAB FEL is a SRF Energy Recovery LINAC capable of running up to 10 mA CW beam with a 74.85 MHz micropulse frequency. For diagnostic reasons and for machine tune up, the micropulse frequency can be reducedmore » to 1.17 MHz, which corresponds to about 160 {mu}A of beam current. It is required that the BPM system would be functional for all micropulse frequencies. By taking into account the headroom for the beam steering and current variations the dynamic range of the RF front end is required to be about 60 dB. A BPM resolution of at least 100 {mu}m is required, whereas better resolution is very desirable to make it possible for more accurate measurements of the electron beam optics. Some results of the RF front end development are presented as well as the first measurements made with an electron beam.« less

  12. Development of BPM Electronics at the JLAB FEL

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Daniel Sexton; Pavel Evtushenko; Kevin Jordan

    2006-05-01

    A new version of BPM electronics based on the AD8362 RMS detector, which is a direct RF to DC converter, is under development at the JLAB FEL. Each of these new BPM electronics utilizes an embedded ColdFire Microprocessor for data processing and communication with the EPICS control system via TCP/IP. The ColdFire runs RTEMS, which is an open source real-time operating system. The JLAB FEL is a SRF Energy Recovery LINAC capable of running up to 10 mA CW beam with the micropulse up to 74.85 MHz. For diagnostic reasons and for the machine tune up, the micropulse frequency canmore » be reduced to 1.17 MHz, which corresponds to about 160 ?A of beam current. It is required that the BPM system would be functional for all micropulse frequencies. By taking into account the headroom for the beam steering and current variations the dynamic range of the RF front end is required to be about 60 dB. A BPM resolution of at least 100 ?m is required, whereas better resolution is very desirable to make it possible for more accurate measurements of the electron beam optics. Some results of the RF front end development are presented as well as the first measurements made with an electron beam.« less

  13. Results from the RF BPM Upgrade Prototype at the Advanced Photon Source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pietryla, Anthony; Lill, Robert; Norum, Eric

    2006-11-20

    The Advanced Photon Source (APS), a third-generation synchrotron light source, has been in operation for 10 years. The monopulse radio frequency (RF) beam position monitor (BPM) is one of three BPM types now employed in the storage ring at the APS. It is a broadband (10 MHz) system designed to measure single-turn and multi-turn beam positions, but it suffers from an aging data acquisition system. The replacement BPM system retains the existing monopulse receivers and replaces the data acquisition system with high-speed analog-to-digital converters (ADCs) and a field programmable gate array (FPGA) that performs the signal processing. A prototype systemmore » was constructed and is currently being evaluated. This paper presents the results obtained from laboratory and field tests of the prototype system.« less

  14. Results from the RF BPM upgrade prototype at the Advanced Photon Source.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pietryla, A.; Lill, R.; Norum, E.

    2006-01-01

    The Advanced Photon Source (APS), a third-generation synchrotron light source, has been in operation for 10 years. The monopulse radio frequency (RF) beam position monitor (BPM) is one of three BPM types now employed in the storage ring at the APS. It is a broadband (10 MHz) system designed to measure single-turn and multi-turn beam positions, but it suffers from an aging data acquisition system. The replacement BPM system retains the existing monopulse receivers and replaces the data acquisition system with high-speed analog-to-digital converters (ADCs) and a field programmable gate array (FPGA) that performs the signal processing. A prototype systemmore » was constructed and is currently being evaluated. This paper presents the results obtained from laboratory and field tests of the prototype system.« less

  15. NSLS-II BPM System Protection from Rogue Mode Coupling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blednykh, A.; Bach, B.; Borrelli, A.

    2011-03-28

    Rogue mode RF shielding has been successfully designed and implemented into the production multipole vacuum chambers. In order to avoid systematic errors in the NSLS-II BPM system we introduced frequency shift of HOM's by using RF metal shielding located in the antechamber slot of each multipole vacuum chamber. To satisfy the pumping requirement the face of the shielding has been perforated with roughly 50 percent transparency. It stays clear of synchrotron radiation in each chamber.

  16. 500 MHz narrowband beam position monitor electronics for electron synchrotrons

    NASA Astrophysics Data System (ADS)

    Mohos, I.; Dietrich, J.

    1998-12-01

    Narrowband beam position monitor electronics were developed in the Forschungszentrum Jülich-IKP for the orbit measurement equipment used at ELSA Bonn. The equipment uses 32 monitor chambers, each with four capacitive button electrodes. The monitor electronics, consisting of an rf signal processing module (BPM-RF) and a data acquisition and control module (BPM-DAQ), sequentially process and measure the monitor signals and deliver calculated horizontal and vertical beam position data via a serial network.

  17. Status of the RF BPM upgrade at the Advanced Photon Source.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pietryla, A.; Bui, H.; Decker, G.

    2008-01-01

    The Advanced Photon Source (APS),a third-generation synchrotron light source, has been in operation for eleven years. The monopulse radio frequency (rf) beam position monitor (BPM) is one of three BPM types now employed in the storage ring at the APS. It is a broadband (10 MHz) system designed to measure single-turn and multi-turn beam positions, but it suffers from an aging data acquisition system. The replacement BPM system retains the existing monopulse receivers and replaces the data acquisition system with high-speed analog-to-digital converters (ADCs) and a field-programmable gate array (FPGA) that performs the signal processing. A first-article system has beenmore » constructed and is currently being evaluated. This paper presents the results of testing of the first-article system as well as the progress made in other areas of this upgrade effort.« less

  18. Comparison of RF BPM Receivers for NSLS-II Project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pinayev,I.; Singh, O.

    2009-05-04

    The NSLS-II Light Source being built at Brookhaven National Laboratory requires submicron stability of the electron orbit in the storage ring in order to utilize fully very small emittances and electron beam sizes. This sets high stability requirements for beam position monitors and a program has been initiated for the purpose of characterizing RF beam position monitor (BPM) receivers in use at other light sources. Present state-of-the-art performance will be contrasted with more recently available technologies.

  19. Development of the PEFP's beam line BPM

    NASA Astrophysics Data System (ADS)

    Ryu, Jin-Yeong; Kwon, Hyeok-Jung; Jang, Ji-Ho; Kim, Han-Sung; Seol, Kyung-Tae; Cho, Yong-Sub

    2013-01-01

    The Proton Engineering Frontier Project (PEFP) has 20-MeV and 100-MeV beam lines to supply proton beams to users. A stripline-type Beam Position Monitor (BPM) was designed and fabricated in order to measure the beam's position in the beam line. The RF properties of the BPM were measured and compared with the simulation. After the sensitivity of the BPM at a test stand had been obtained, we performed a beam test in a test beam line of the PEFP 20-MeV proton linac.

  20. Commissioning of the soft x-ray undulator beamline at the Siam Photon Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nakajima, Hideki, E-mail: hideki@slri.or.th; Chaichuay, Sarunyu; Sudmuang, Porntip

    2016-07-27

    The synchrotron radiation from the first undulator at the Siam Photon Laboratory was characterized with the photon beam position monitors (BPMs) and grating monochromator. The soft x-ray undulator beamline employs a varied line-spacing plane grating monochromator with three interchangeable gratings. Since 2010, the beamline has delivered photons with energy of 40-160 and 220-1040 eV at the resolving power of 10,000 for user services at the two end- stations that utilize the photoemission electron spectroscopy and microscopy techniques. The undulator power-density distributions measured by the 0.05-mm wire-scan BPM were in good agreement with those in simulation. The flux-density distributions were evaluatedmore » in the red-shift measurements, which identify the central cone of radiation and its distribution. Since 2014, the operation of the other insertion devices in the storage ring has started, and consequently bought about the increases in the emittance from 41 to 61 nm·rad and the coupling constant from 4 to 11%. The local electron-orbit correction greatly improved the alignment of the electron beam in the undulator section resulting in the improvements of the photon flux and harmonics peaks of the undulator radiation.« less

  1. Analysis of a Novel Diffractive Scanning Wire Beam Position Monitor (BPM) for Discriminative Profiling of Electron Vs. X Ray Beams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tatchyn, Roman; /SLAC

    2011-09-01

    Recent numerical studies of Free Electron Lasers (FELs) operating in the Self Amplified Spontaneous Emission (SASE) regime indicate a large sensitivity of the gain to the degree of transverse overlap (and associated phase coherence) between the electron and photon beams traveling down the insertion device. Simulations of actual systems imply that accurate detection and correction for this relative loss of overlap, rather than correction for the absolute departure of the electron beam from a fixed axis, is the preferred function of an FEL amplifier's Beam Position Monitor (BPM) and corrector systems. In this note we propose a novel diffractive BPMmore » with the capability of simultaneously detecting and resolving the absolute (and relative) transverse positions and profiles of electron and x-ray beams co-propagating through an undulator. We derive the equations governing the performance of the BPM and examine its predicted performance for the SLAC Linac Coherent Light Source (LCLS), viz., for profiling multi-GeV electron bunches co-propagating with one-to-several-hundred keV x-ray beams. Selected research and development (r&d) tasks for fabricating and testing the proposed BPM are discussed.« less

  2. Performance of a Nanometer Resolution BPM System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vogel, V; Hayano, H; Honda, Y

    2005-10-14

    International Linear Collider (ILC) interaction region beam sizes and component position stability requirements will be as small as a few nanometers. it is important to the ongoing ILC design effort to demonstrate that these tolerances can be achieved--ideally using beam-based stability measurements. It has been estimated that an RF cavity BPM with modern waveform processing could provide a position measurement resolution of less than one nanometer. Such a system could form the basis of the desired beam-based stability measurement, as well as be used for other specialized purposes. They have developed a high resolution RF cavity BPM and associated electronics.more » A triplet comprised of these BPMs has been installed in the extraction line of the KEK Accelerator Test Facility (ATF) for testing with its ultra-low emittance beam. The three BPMs are rigidly mounted inside an alignment frame on six variable-length struts which can be used to move the BPMs in position and angle. they have developed novel methods for extracting the position and tilt information from the BPM signals including a robust calibration algorithm which is immune to beam jitter. To date, they have been able to demonstrate a resolution of approximately 20 nm over a dynamic range of {+-} 20 {micro}m. They report on the progress of these ongoing tests.« less

  3. APS Storage Ring Monopulse RF BPM Upgrade

    NASA Astrophysics Data System (ADS)

    Lill, R.; Pietryla, A.; Norum, E.; Lenkszus, F.

    2004-11-01

    The Advanced Photon Source (APS) is a third-generation synchrotron light source in its ninth year of operation. The storage ring monopulse radio frequency (rf) beam position monitor (BPM) was designed to measure single-turn and multi-turn beam positions for operations and machine physics studies. Many of the components used in the original design are obsolete and costly to replace. In this paper we present a proposal to upgrade the monopulse rf BPMs in which the existing system hardware is repartitioned and the aging data acquisition system is replaced. By replacing only the data acquisition system, we will demonstrate a cost-effective approach to improved beam stability, reliability, and enhanced postmortem capabilities. An eight-channel ADC/digitizer VXI board with sampling rate of up to 105 MHz (per channel) and 14-bit resolution coupled with a field-programmable gate array and embedded central processing will provide the flexibility to revitalize this system for another decade of operation. We will discuss the upgrade system specifications, design, and prototype test results.

  4. Beam property measurement of a 300-kV ion source test stand for a 1-MV electrostatic accelerator

    NASA Astrophysics Data System (ADS)

    Park, Sae-Hoon; Kim, Dae-Il; Kim, Yu-Seok

    2016-09-01

    The KOMAC (Korea Multi-purpose Accelerator Complex) has been developing a 300-kV ion source test stand for a 1-MV electrostatic accelerator for industrial purposes. A RF ion source was operated at 200 MHz with its matching circuit. The beam profile and emittance were measured behind an accelerating column to confirm the beam property from the RF ion source. The beam profile was measured at the end of the accelerating tube and at the beam dump by using a beam profile monitor (BPM) and wire scanner. An Allison-type emittance scanner was installed behind the beam profile monitor (BPM) to measure the beam density in phase space. The measurement results for the beam profile and emittance are presented in this paper.

  5. Methodological Preliminaries to the Development of an Expert System for Aerial Photo Interpretation.

    DTIC Science & Technology

    1984-01-01

    Region prl.7.2 Colorado Plateaus Province prl.7.2.1 High Plateaus of Utah Region prl.7.2.2 Uinta Basin Region prl.7.2.3 Canyon Lands Region prI.7.2.4...have a flat to undulating basin --does it?). If a majority of the questions generate negative answers some other hypothesis is sought. % (13) All...rf2.2 Lineaments rf2.3 Troughs -f2.4 Joints f2.5 Escarpments rf2.6 Gorges rfZ.7 Folds Rock Forms 3 Domes Rock Forms 4 Canyons Rock Forms 5 Basins

  6. CoPt/TiN films nanopatterned by RF plasma etching towards dot-patterned magnetic media

    NASA Astrophysics Data System (ADS)

    Szívós, János; Pothorszky, Szilárd; Soltys, Jan; Serényi, Miklós; An, Hongyu; Gao, Tenghua; Deák, András; Shi, Ji; Sáfrán, György

    2018-03-01

    CoPt thin films as possible candidates for Bit Patterned magnetic Media (BPM) were prepared and investigated by electron microscopy techniques and magnetic measurements. The structure and morphology of the Direct Current (DC) sputtered films with N incorporation were revealed in both as-prepared and annealed state. Nanopatterning of the samples was carried out by means of Radio Frequency (RF) plasma etching through a Langmuir-Blodgett film of silica nanospheres that is a fast and high throughput technique. As a result, the samples with hexagonally arranged 100 nm size separated dots of fct-phase CoPt were obtained. The influence of the order of nanopatterning and anneling on the nanostructure formation was revealed. The magnetic properties of the nanopatterned fct CoPt films were investigated by Vibrating Sample Magnetometer (VSM) and Magnetic Force Microscopy (MFM). The results show that CoPt thin film nanopatterned by means of the RF plasma etching technique is promising candidate to a possible realization of BPM. Furthermore, this technique is versatile and suitable for scaling up to technological and industrial applications.

  7. Performance of a Nanometer Resolution BPM System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Walston, S.; Chung, C.; Fitsos, P.

    2007-04-24

    International Linear Collider (ILC) interaction region beam sizes and component position stability requirements will be as small as a few nanometers. It is important to the ILC design effort to demonstrate that these tolerances can be achieved ideally using beam-based stability measurements. It has been estimated that RF cavity beam position monitors (BPMs) could provide position measurement resolutions of less than one nanometer and could form the basis of the desired beam-based stability measurement. We have developed a high resolution RF cavity BPM system. A triplet of these BPMs has been installed in the extraction line of the KEK Acceleratormore » Test Facility (ATF) for testing with its ultra-low emittance beam. The three BPMs are rigidly mounted inside an alignment frame on variable-length struts which allow movement in position and angle. We have developed novel methods for extracting the position and tilt information from the BPM signals including a calibration algorithm which is immune to beam jitter. To date, we have been able to demonstrate a resolution of approximately 20 nm over a dynamic range of +/- 20 microns. We report on the progress of these ongoing tests.« less

  8. Effect of TE Mode Power on the PEP II LER BPM System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ng, Cho-K

    2011-08-26

    The beam chamber of the PEP-II B-Factory Low Energy Ring (LER) arc sections is connected to an antechamber for the absorption of synchrotron radiation on discrete photon stops. The presence of the antechamber substantially reduces the cutoff frequency of the vacuum chamber and, in particular, allows the propagation of higher-order-mode (HOM) TE power generated by beamline components at the BPM signal processing frequency. Calculations of the transmission properties of the TE mode in different sections of the vacuum chamber show that the power is trapped between widely separated bellows in the arc sections. Because of the narrow signal bandwidth andmore » weak coupling of the TE mode to the BPM buttons, the noise contributed by the HOM TE power will not produce a noticeable effect on the BPM position signal voltage. The LER arc vacuum chamber employs an antechamber with a discrete photon stop for absorption of synchrotron radiation and with pumps for maintaining pressure below 10 nTorr [1]. The horizontal dimensions of the antechambers at the pumping chamber section and the magnet chamber section are larger or comparable to that of the beam chamber. Because of the increase in the horizontal dimension, the cutoff frequency of the TE10-like mode (in rectangular coordinates) of the vacuum chamber is considerably reduced and, in particular, is less than the BPM signal processing frequency at 952 MHz. TE power propagating in the vacuum chamber will penetrate through the BPM buttons and will affect the pickup signal if its magnitude is not properly controlled. It is the purpose of this note to clarify various issues pertaining to this problem. TE power is generated when the beam passes a noncylindrically symmetric beamline component such as the RF cavity, the injection region, the IR crotch and the IP region. The beampipes connected to these components have TE cutoff frequencies greater than 952 MHz (for example, the TE cutoff frequency of the RF cavity beampipe is 1.8 GHz), and hence no TE power at this frequency propagates from the component. TE power can also be generated by the scattering of TM power through these beamline components. Since the cutoff frequency of the TM mode is in general higher than that of the TE mode, this mechanism is not pertinent to the problem related to the BPM signal. Consequently, the TE power that needs to be considered is mainly generated by components of the LER arc vacuum chamber, where the TE cutoff frequency is less than the BPM processing frequency.« less

  9. Design of the 15 GHz BPM test bench for the CLIC test facility to perform precise stretched-wire RF measurements

    NASA Astrophysics Data System (ADS)

    Zorzetti, Silvia; Fanucci, Luca; Galindo Muñoz, Natalia; Wendt, Manfred

    2015-09-01

    The Compact Linear Collider (CLIC) requires a low emittance beam transport and preservation, thus a precise control of the beam orbit along up to 50 km of the accelerator components in the sub-μm regime is required. Within the PACMAN3 (Particle Accelerator Components Metrology and Alignment to the Nanometer Scale) PhD training action a study with the objective of pre-aligning the electrical centre of a 15 GHz cavity beam position monitor (BPM) to the magnetic centre of the main beam quadrupole is initiated. Of particular importance is the design of a specific test bench to study the stretched-wire setup for the CLIC Test Facility (CTF3) BPM, focusing on the aspects of microwave signal excitation, transmission and impedance-matching, as well as the mechanical setup and reproducibility of the measurement method.

  10. Performance of a high resolution cavity beam position monitor system

    NASA Astrophysics Data System (ADS)

    Walston, Sean; Boogert, Stewart; Chung, Carl; Fitsos, Pete; Frisch, Joe; Gronberg, Jeff; Hayano, Hitoshi; Honda, Yosuke; Kolomensky, Yury; Lyapin, Alexey; Malton, Stephen; May, Justin; McCormick, Douglas; Meller, Robert; Miller, David; Orimoto, Toyoko; Ross, Marc; Slater, Mark; Smith, Steve; Smith, Tonee; Terunuma, Nobuhiro; Thomson, Mark; Urakawa, Junji; Vogel, Vladimir; Ward, David; White, Glen

    2007-07-01

    It has been estimated that an RF cavity Beam Position Monitor (BPM) could provide a position measurement resolution of less than 1 nm. We have developed a high resolution cavity BPM and associated electronics. A triplet comprised of these BPMs was installed in the extraction line of the Accelerator Test Facility (ATF) at the High Energy Accelerator Research Organization (KEK) for testing with its ultra-low emittance beam. The three BPMs were each rigidly mounted inside an alignment frame on six variable-length struts which could be used to move the BPMs in position and angle. We have developed novel methods for extracting the position and tilt information from the BPM signals including a robust calibration algorithm which is immune to beam jitter. To date, we have demonstrated a position resolution of 15.6 nm and a tilt resolution of 2.1 μrad over a dynamic range of approximately ±20 μm.

  11. Waveguide-Mode Terahertz Free Electron Lasers Driven by Magnetron-Based Microtrons

    NASA Astrophysics Data System (ADS)

    Jeong, Young Uk; Miginsky, Sergey; Gudkov, Boris; Lee, Kitae; Mun, Jungho; Shim, Gyu Il; Bae, Sangyoon; Kim, Hyun Woo; Jang, Kyu-Ha; Park, Sunjeong; Park, Seong Hee; Vinokurov, Nikolay

    2016-04-01

    We have developed small-sized terahertz free-electron lasers by using low-cost and compact microtrons combining with magnetrons as high-power RF sources. We could stabilize the bunch repetition rate by optimizing a modulator for the magnetron and by coupling the magnetron with an accelerating cavity in the microtron. By developing high-performance undulators and low-loss waveguide-mode resonators having small cross-sectional areas, we could strengthen the interaction between the electron beam and the THz wave inside the FEL resonators to achieve lasing even with low-current electron beams from the microtron. We used a parallel-plate waveguide in a planar electromagnet undulator for our first THz FEL. We try to reduce the size of the FEL resonator by combining a dielectric-coated circular waveguide and a variable-period helical undulator to realize a table-top THz FEL for applying it to the security inspection on airports.

  12. OPERATIONAL EXPERIENCE WITH BEAM ABORT SYSTEM FOR SUPERCONDUCTING UNDULATOR QUENCH MITIGATION*

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harkay, Katherine C.; Dooling, Jeffrey C.; Sajaev, Vadim

    A beam abort system has been implemented in the Advanced Photon Source storage ring. The abort system works in tandem with the existing machine protection system (MPS), and its purpose is to control the beam loss location and, thereby, minimize beam loss-induced quenches at the two superconducting undulators (SCUs). The abort system consists of a dedicated horizontal kicker designed to kick out all the bunches in a few turns after being triggered by MPS. The abort system concept was developed on the basis of single- and multi-particle tracking simulations using elegant and bench measurements of the kicker pulse. Performance ofmore » the abort system—kick amplitudes and loss distributions of all bunches—was analyzed using beam position monitor (BPM) turn histories, and agrees reasonably well with the model. Beam loss locations indicated by the BPMs are consistent with the fast fiber-optic beam loss monitor (BLM) diagnostics described elsewhere [1,2]. Operational experience with the abort system, various issues that were encountered, limitations of the system, and quench statistics are described.« less

  13. A novel electromagnetic design and a new manufacturing process for the cavity BPM (Beam Position Monitor)

    NASA Astrophysics Data System (ADS)

    Dal Forno, Massimo; Craievich, Paolo; Baruzzo, Roberto; De Monte, Raffaele; Ferianis, Mario; Lamanna, Giuseppe; Vescovo, Roberto

    2012-01-01

    The Cavity Beam Position Monitor (BPM) is a beam diagnostic instrument which, in a seeded Free Electron Laser (FEL), allows the measurement of the electron beam position in a non-destructive way and with sub-micron resolution. It is composed by two resonant cavities called reference and position cavity, respectively. The measurement exploits the dipole mode that arises when the electron bunch passes off axis. In this paper we describe the Cavity BPM that has been designed and realized in the context of the FERMI@Elettra project [1]. New strategies have been adopted for the microwave design, for both the reference and the position cavities. Both cavities have been simulated by means of Ansoft HFSS [2] and CST Particle Studio [3], and have been realized using high precision lathe and wire-EDM (Electro-Discharge) machine, with a new technique that avoids the use of the sinker-EDM machine. Tuners have been used to accurately adjust the working frequencies for both cavities. The RF parameters have been estimated, and the modifications of the resonant frequencies produced by brazing and tuning have been evaluated. Finally, the Cavity BPM has been installed and tested in the presence of the electron beam.

  14. X -band rf driven free electron laser driver with optics linearization

    DOE PAGES

    Sun, Yipeng; Emma, Paul; Raubenheimer, Tor; ...

    2014-11-13

    In this paper, a compact hard X-ray free electron lasers (FEL) design is proposed with all X-band rf acceleration and two stage bunch compression. It eliminates the need of a harmonic rf linearization section by employing optics linearization in its first stage bunch compression. Quadrupoles and sextupoles are employed in a bunch compressor one (BC1) design, in such a way that second order longitudinal dispersion of BC1 cancels the second order energy correlation in the electron beam. Start-to-end 6-D simulations are performed with all the collective effects included. Emittance growth in the horizontal plane due to coherent synchrotron radiation ismore » investigated and minimized, to be on a similar level with the successfully operating Linac coherent light source (LCLS). At a FEL radiation wavelength of 0.15 nm, a saturation length of 40 meters can be achieved by employing an undulator with a period of 1.5 cm. Without tapering, a FEL radiation power above 10 GW is achieved with a photon pulse length of 50 fs, which is LCLS-like performance. The overall length of the accelerator plus undulator is around 250 meters which is much shorter than the LCLS length of 1230 meters. That makes it possible to build hard X-ray FEL in a laboratory with limited size.« less

  15. Brevibacillus laterosporus strain BPM3, a potential biocontrol agent isolated from a natural hot water spring of Assam, India.

    PubMed

    Saikia, R; Gogoi, D K; Mazumder, S; Yadav, A; Sarma, R K; Bora, T C; Gogoi, B K

    2011-03-20

    A bacterial strain designated as BPM3 isolated from mud of a natural hot water spring of Nambar Wild Life Sanctuary, Assam, India, strongly inhibited growth of phytopathogenic fungi (Fusarium oxysporum f. sp. ciceri, F. semitectum, Magnaporthe grisea and Rhizoctonia oryzae) and gram-positive bacterium (Staphylococcus aureus). The maximum growth and antagonistic activity was recorded at 30°C, pH 8.5 when starch and peptone were amended as carbon and nitrogen sources, respectively. In greenhouse experiment, this bacterium (BPM3) suppressed blast disease of rice by 30-67% and protected the weight loss by 35-56.5%. The maximum disease protection (67%) and weight loss protection (56.5%) were recorded when the bacterium was applied before 2 days of the pathogen inoculation. Antifungal and antibacterial compounds were isolated from the bacterium which also inhibited the growth of these targeted pathogens. The compounds were purified and on spectroscopic analysis of a purified fraction having R(f) 0.22 which showed strong antifungal and antibacterial activity indicated the presence of C-H, carbonyl group, dimethyl group, -CH(2) and methyl group. The bacterium was characterized by morphological, biochemical and molecular approaches and confirmed that the strain BPM3 is Brevibacillus laterosporus. Copyright © 2010 Elsevier GmbH. All rights reserved.

  16. An Undulator-Based Laser Wakefield Accelerator Electron Beam Diagnostic

    NASA Astrophysics Data System (ADS)

    Bakeman, Michael S.

    Currently particle accelerators such as the Large Hadron Collider use RF cavities with a maximum field gradient of 50-100 MV/m to accelerate particles over long distances. A new type of plasma based accelerator called a Laser Plasma Accelerator (LPA) is being investigated at the LOASIS group at Lawrence Berkeley National Laboratory which can sustain field gradients of 10-100 GV/m. This new type of accelerator offers the potential to create compact high energy accelerators and light sources. In order to investigate the feasibility of producing a compact light source an undulator-based electron beam diagnostic for use on the LOASIS LPA has been built and calibrated. This diagnostic relies on the principal that the spectral analysis of synchrotron radiation from an undulator can reveal properties of the electron beam such as emittance, energy and energy spread. The effects of electron beam energy spread upon the harmonics of undulator produced synchrotron radiation were derived from the equations of motion of the beam and numerically simulated. The diagnostic consists of quadrupole focusing magnets to collimate the electron beam, a 1.5 m long undulator to produce the synchrotron radiation, and a high resolution high gain XUV spectrometer to analyze the radiation. The undulator was aligned and tuned in order to maximize the flux of synchrotron radiation produced. The spectrometer was calibrated at the Advanced Light Source, with the results showing the ability to measure electron beam energy spreads at resolutions as low as 0.1% rms, a major improvement over conventional magnetic spectrometers. Numerical simulations show the ability to measure energy spreads on realistic LPA produced electron beams as well as the improvements in measurements made with the quadrupole magnets. Experimentally the quadrupoles were shown to stabilize and focus the electron beams at specific energies for their insertion into the undulator, with the eventual hope of producing an all optical Free Electron Laser operating in the XUV and soft x-ray regimes.

  17. Doubling The Intensity Of An ERL Based Light Source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Andrew Hutton

    2005-05-01

    A light source based on an Energy Recovered Linac (ERL) [1] consists of a superconducting linac and a transfer line that includes wigglers and undulators to produce the synchrotron light. The transfer line brings the electron bunches back to the beginning of the linac so that their energy can be recovered when they traverse the linac a second time, {lambda}/2 out of RF phase. There is another interesting condition when the length of the transfer line is (n {+-} 1/4) {lambda}. In this case, the electrons drift through on the zero RF crossing, and make a further pass around themore » transfer line, effectively doubling the circulating current in the wigglers and undulators. On the third pass through the linac, they will be decelerated and their energy recovered. The longitudinal focusing at the zero crossing is a problem, but it can be canceled if the drifting beam sees a positive energy gradient for the first half of the linac and a negative gradient for the second half (or vice versa). This paper presents a proposal to use a double chicane at the center of the linac to provide this focusing inversion for the drifting beam while leaving the accelerating and decelerating beams on crest. [1] G. R. Neil, et al, Phys. Rev. Let. 84, 662 2000« less

  18. Upgrade of BPM Electronics for the SPring-8 Storage Ring

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sasaki, Shigeki; Fujita, Takahiro; Shoji, Masazumi

    2006-11-20

    SPring-8, a 3rd generation synchrotron light source, has operated since 1997. Improvement of BPM performance is required as a part of upgrading activities of the storage ring as a light source. We have developed new electronics circuits for signal processing of the storage ring BPM, with target performance of sub-{mu}m range resolution with sufficiently fast measurement speed and good long-term stability. A set of the new circuits consists of multiplexers, an RF amplifier, a mixer, an IF amplifier, and a local oscillator for analog signal processing. The IF amplifier outputs are sampled with 16-bit 2-MSPS ADC on ADC boards andmore » the data are sent to a DSP board. The sampled data are processed and converted to position information in the DSP. A multiplexing method was employed to have a better stability of the performance by cancellation of variation common to each channel. Evaluation of the performance by using a prototype shows that position resolution well into the sub-{mu}m range has been achieved with a bandwidth of 1 kHz, and long-term stability of within 1 {mu}m has also been achieved.« less

  19. Performance of a reentrant cavity beam position monitor

    NASA Astrophysics Data System (ADS)

    Simon, Claire; Luong, Michel; Chel, Stéphane; Napoly, Olivier; Novo, Jorge; Roudier, Dominique; Rouvière, Nelly; Baboi, Nicoleta; Mildner, Nils; Nölle, Dirk

    2008-08-01

    The beam-based alignment and feedback systems, essential operations for the future colliders, require high resolution beam position monitors (BPMs). In the framework of the European CARE/SRF program, a reentrant cavity BPM with its associated electronics was developed by the CEA/DSM/Irfu in collaboration with DESY. The design, the fabrication, and the beam test of this monitor are detailed within this paper. This BPM is designed to be inserted in a cryomodule, work at cryogenic temperature in a clean environment. It has achieved a resolution better than 10μm and has the possibility to perform bunch to bunch measurements for the x-ray free electron laser (X-FEL) and the International Linear Collider (ILC). Its other features are a small size of the rf cavity, a large aperture (78 mm), and an excellent linearity. A first prototype of a reentrant cavity BPM was installed in the free electron laser in Hamburg (FLASH), at Deutsches Elektronen-Synchrotron (DESY) and demonstrated its operation at cryogenic temperature inside a cryomodule. The second, installed, also, in the FLASH linac to be tested with beam, measured a resolution of approximately 4μm over a dynamic range ±5mm in single bunch.

  20. Energy Recovery Linacs for Light Source Applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    George Neil

    2011-04-01

    Energy Recovery Linacs are being considered for applications in present and future light sources. ERLs take advantage of the continuous operation of superconducting rf cavities to accelerate high average current beams with low losses. The electrons can be directed through bends, undulators, and wigglers for high brightness x ray production. They are then decelerated to low energy, recovering power so as to minimize the required rf drive and electrical draw. When this approach is coupled with advanced continuous wave injectors, very high power, ultra-short electron pulse trains of very high brightness can be achieved. This paper will review the statusmore » of worldwide programs and discuss the technology challenges to provide such beams for photon production.« less

  1. Prototyping of beam position monitor for medium energy beam transport section of RAON heavy ion accelerator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jang, Hyojae, E-mail: lkcom@ibs.re.kr; Jin, Hyunchang; Jang, Ji-Ho

    2016-02-15

    A heavy ion accelerator, RAON is going to be built by Rare Isotope Science Project in Korea. Its target is to accelerate various stable ions such as uranium, proton, and xenon from electron cyclotron resonance ion source and some rare isotopes from isotope separation on-line. The beam shaping, charge selection, and modulation should be applied to the ions from these ion sources because RAON adopts a superconducting linear accelerator structure for beam acceleration. For such treatment, low energy beam transport, radio frequency quadrupole, and medium energy beam transport (MEBT) will be installed in injector part of RAON accelerator. Recently, developmentmore » of a prototype of stripline beam position monitor (BPM) to measure the position of ion beams in MEBT section is under way. In this presentation, design of stripline, electromagnetic (EM) simulation results, and RF measurement test results obtained from the prototyped BPM will be described.« less

  2. A metrology system for a high resolution cavity beam position monitor system

    NASA Astrophysics Data System (ADS)

    Walston, Sean; Boogert, Stewart; Chung, Carl; Fitsos, Pete; Frisch, Joe; Gronberg, Jeff; Hayano, Hitoshi; Hinton, Shantell; Honda, Yosuke; Khainovski, Oleg; Kolomensky, Yury; Loscutoff, Peter; Lyapin, Alexey; Malton, Stephen; May, Justin; McCormick, Douglas; Meller, Robert; Miller, David; Orimoto, Toyoko; Ross, Marc; Slater, Mark; Smith, Steve; Smith, Tonee; Terunuma, Nobuhiro; Thomson, Mark; Urakawa, Junji; Vogel, Vladimir; Ward, David; White, Glen

    2013-11-01

    International Linear Collider (ILC) interaction region beam sizes and component position stability requirements will likely be as small as a few nanometers. It is important to the ILC design effort to demonstrate that these tolerances can be achieved-ideally using a beam-based stability measurement. We developed a high resolution RF cavity Beam Position Monitor (BPM) system. A triplet of these BPMs, installed in the extraction line of the KEK Accelerator Test Facility (ATF) and tested with its ultra-low emittance beam, achieved a position measurement resolution of 15 nm. A metrology system for the three BPMs was subsequently installed. This system employed optical encoders to measure each BPM's position and orientation relative to a zero-coefficient of thermal expansion carbon fiber frame. We have demonstrated that the three BPMs behave as a rigid-body at the level of less than 5 nm.

  3. Submacropulse electron-beam dynamics correlated with higher-order modes in Tesla-type superconducting rf cavities

    NASA Astrophysics Data System (ADS)

    Lumpkin, A. H.; Thurman-Keup, R.; Edstrom, D.; Ruan, J.; Eddy, N.; Prieto, P.; Napoly, O.; Carlsten, B. E.; Bishofberger, K.

    2018-06-01

    We report the direct observations of submacropulse beam centroid oscillations correlated with higher order modes (HOMs) which were generated by off-axis electron beam steering in TESLA-type superconducting rf cavities. The experiments were performed at the Fermilab Accelerator Science and Technology (FAST) facility using its unique configuration of a photocathode rf gun injecting beam into two separated nine-cell cavities in series with corrector magnets and beam position monitors (BPMs) located before, between, and after them. Oscillations of ˜100 kHz in the vertical plane and ˜380 kHz in the horizontal plane with up to 600 -μ m amplitudes were observed in a 3-MHz micropulse repetition rate beam with charges of 100, 300, 500, and 1000 pC /b . However, the effects were much reduced at 100 pC /b . The measurements were based on HOM detector circuitry targeting the first and second dipole passbands, rf BPM bunch-by-bunch array data, imaging cameras, and a framing camera. Calculations reproduced the oscillation frequencies of the phenomena in the vertical case. In principle, these fundamental results may be scaled to cryomodule configurations of major accelerator facilities.

  4. Submacropulse electron-beam dynamics correlated with higher-order modes in Tesla-type superconducting rf cavities

    DOE PAGES

    Lumpkin, A. H.; Thurman-Keup, R.; Edstrom, D.; ...

    2018-06-04

    Here, we report the direct observations of submacropulse beam centroid oscillations correlated with higher order modes (HOMs) which were generated by off-axis electron beam steering in TESLA-type superconducting rf cavities. The experiments were performed at the Fermilab Accelerator Science and Technology (FAST) facility using its unique configuration of a photocathode rf gun injecting beam into two separated nine-cell cavities in series with corrector magnets and beam position monitors (BPMs) located before, between, and after them. Oscillations of ~100 kHz in the vertical plane and ~380 kHz in the horizontal plane with up to 600-μm amplitudes were observed in a 3-MHzmore » micropulse repetition rate beam with charges of 100, 300, 500, and 1000 pC/b. However, the effects were much reduced at 100 pC/b. The measurements were based on HOM detector circuitry targeting the first and second dipole passbands, rf BPM bunch-by-bunch array data, imaging cameras, and a framing camera. Calculations reproduced the oscillation frequencies of the phenomena in the vertical case. In principle, these fundamental results may be scaled to cryomodule configurations of major accelerator facilities.« less

  5. Theory of multiwave mixing within the superconducting kinetic-inductance traveling-wave amplifier

    NASA Astrophysics Data System (ADS)

    Erickson, R. P.; Pappas, D. P.

    2017-03-01

    We present a theory of parametric mixing within the coplanar waveguide (CPW) of a superconducting nonlinear kinetic-inductance traveling-wave (KIT) amplifier engineered with periodic dispersion loadings. This is done by first developing a metamaterial band theory of the dispersion-engineered KIT using a Floquet-Bloch construction and then applying it to the description of mixing of the nonlinear RF traveling waves. Our theory allows us to calculate signal gain versus signal frequency in the presence of a frequency stop gap, based solely on loading design. We present results for both three-wave mixing (3WM), with applied dc bias, and four-wave mixing (4WM), without dc. Our theory predicts an intrinsic and deterministic origin to undulations of 4WM signal gain with signal frequency, apart from extrinsic sources, such as impedance mismatch, and shows that such undulations are absent from 3WM signal gain achievable with dc. Our theory is extensible to amplifiers based on Josephson junctions in a lumped LC-ladder transmission line (TWPA).

  6. Advanced diagnosis of the temporal characteristics of ultra-short electron beams

    NASA Astrophysics Data System (ADS)

    Otake, Yuji

    2011-05-01

    Monitoring the temporal structure of an ultra-short electron beam is an indispensable function in order to tune a machine to obtain a highly qualified beam for a recent sophisticated accelerator, such as an X-ray free electron laser (XFEL), and to maintain stable X-ray laser operation. For this purpose, various instruments, such as an HEM11-mode RF beam deflector (RFDEF), a screen monitor (SCM), an electro-optic (EO) sampling method that uses a ZnTe crystal, and a beam position monitor (BPM) have been developed. The SCM that is used to observe the deflected beam image has a position resolution of 2.5 μm, which corresponds to a temporal resolution of 0.5 fs and it is installed at a position 5 m downstream from the RFDEF. The EO sampling method showed the ability to observe an electron bunch length for up to 300 fs (FWHM) at the SCSS test accelerator. The phase reference cavity of the BPM has an additional function of providing beam arrival timing information. A test for the BPM showed temporal fluctuation of 46 fs on the beam arrival timing at the test accelerator. These monitors with high temporal resolutions allow us to achieve the fine beam tuning demanded for the XFEL. The above-mentioned activities are described in this paper as a review article.

  7. High field gradient particle accelerator

    DOEpatents

    Nation, John A.; Greenwald, Shlomo

    1989-01-01

    A high electric field gradient electron accelerator utilizing short duration, microwave radiation, and capable of operating at high field gradients for high energy physics applications or at reduced electric field gradients for high average current intermediate energy accelerator applications. Particles are accelerated in a smooth bore, periodic undulating waveguide, wherein the period is so selected that the particles slip an integral number of cycles of the r.f. wave every period of the structure. This phase step of the particles produces substantially continuous acceleration in a traveling wave without transverse magnetic or other guide means for the particle.

  8. An Autonomous Wireless Sensor Node With Asynchronous ECG Monitoring in 0.18 μ m CMOS.

    PubMed

    Mansano, Andre L; Li, Yongjia; Bagga, Sumit; Serdijn, Wouter A

    2016-06-01

    The design of a 13.56 MHz/402 MHz autonomous wireless sensor node with asynchronous ECG monitoring for near field communication is presented. The sensor node consists of an RF energy harvester (RFEH), a power management unit, an ECG readout, a data encoder and an RF backscattering transmitter. The energy harvester supplies the system with 1.25 V and offers a power conversion efficiency of 19% from a -13 dBm RF source at 13.56 MHz. The power management unit regulates the output voltage of the RFEH to supply the ECG readout with VECG = 0.95 V and the data encoder with VDE = 0.65 V . The ECG readout comprises an analog front-end (low noise amplifier and programmable voltage to current converter) and an asynchronous level crossing ADC with 8 bits resolution. The ADC output is encoded by a pulse generator that drives a backscattering transmitter at 402 MHz. The total power consumption of the sensor node circuitry is 9.7 μ W for a data rate of 90 kb/s and a heart rate of 70 bpm. The chip has been designed in a 0.18 μm CMOS process and shows superior RF input power sensitivity and lower power consumption when compared to previous works.

  9. Progress toward the Wisconsin Free Electron Laser

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bisognano, Joseph; Eisert, D; Fisher, M V

    2011-03-01

    The University of Wisconsin-Madison/Synchrotron Radiation Center is advancing its design for a seeded VUV/soft X-ray Free Electron Laser facility called WiFEL. To support this vision of an ultimate light source, we are pursuing a program of strategic R&D addressing several crucial elements. This includes development of a high repetition rate, VHF superconducting RF electron gun, R&D on photocathode materials by ARPES studies, and evaluation of FEL facility architectures (e.g., recirculation, compressor scenarios, CSR dechirping, undulator technologies) with the specific goal of cost containment. Studies of high harmonic generation for laser seeding are also planned.

  10. High field gradient particle accelerator

    DOEpatents

    Nation, J.A.; Greenwald, S.

    1989-05-30

    A high electric field gradient electron accelerator utilizing short duration, microwave radiation, and capable of operating at high field gradients for high energy physics applications or at reduced electric field gradients for high average current intermediate energy accelerator applications is disclosed. Particles are accelerated in a smooth bore, periodic undulating waveguide, wherein the period is so selected that the particles slip an integral number of cycles of the r.f. wave every period of the structure. This phase step of the particles produces substantially continuous acceleration in a traveling wave without transverse magnetic or other guide means for the particle. 10 figs.

  11. A preliminary design of the collinear dielectric wakefield accelerator

    NASA Astrophysics Data System (ADS)

    Zholents, A.; Gai, W.; Doran, S.; Lindberg, R.; Power, J. G.; Strelnikov, N.; Sun, Y.; Trakhtenberg, E.; Vasserman, I.; Jing, C.; Kanareykin, A.; Li, Y.; Gao, Q.; Shchegolkov, D. Y.; Simakov, E. I.

    2016-09-01

    A preliminary design of the multi-meter long collinear dielectric wakefield accelerator that achieves a highly efficient transfer of the drive bunch energy to the wakefields and to the witness bunch is considered. It is made from 0.5 m long accelerator modules containing a vacuum chamber with dielectric-lined walls, a quadrupole wiggler, an rf coupler, and BPM assembly. The single bunch breakup instability is a major limiting factor for accelerator efficiency, and the BNS damping is applied to obtain the stable multi-meter long propagation of a drive bunch. Numerical simulations using a 6D particle tracking computer code are performed and tolerances to various errors are defined.

  12. Development of a Hard X-ray Beam Position Monitor for Insertion Device Beams at the APS

    NASA Astrophysics Data System (ADS)

    Decker, Glenn; Rosenbaum, Gerd; Singh, Om

    2006-11-01

    Long-term pointing stability requirements at the Advanced Photon Source (APS) are very stringent, at the level of 500 nanoradians peak-to-peak or better over a one-week time frame. Conventional rf beam position monitors (BPMs) close to the insertion device source points are incapable of assuring this level of stability, owing to mechanical, thermal, and electronic stability limitations. Insertion device gap-dependent systematic errors associated with the present ultraviolet photon beam position monitors similarly limit their ability to control long-term pointing stability. We report on the development of a new BPM design sensitive only to hard x-rays. Early experimental results will be presented.

  13. Right diaphragmatic paralysis following endocardial cryothermal ablation of inappropriate sinus tachycardia.

    PubMed

    Vatasescu, Radu; Shalganov, Tchavdar; Kardos, Attila; Jalabadze, Khatuna; Paprika, Dora; Gyorgy, Margit; Szili-Torok, Tamas

    2006-10-01

    Inappropriate sinus tachycardia (IST) is a rare disorder amenable to catheter ablation when refractory to medical therapy. Radiofrequency (RF) catheter modification/ablation of the sinus node (SN) is the usual approach, although it can be complicated by right phrenic nerve paralysis. We describe a patient with IST, who had symptomatic recurrences despite previous acutely successful RF SN modifications, including the use of electroanatomical mapping/navigation system. We decided to try transvenous cryothermal modification of the SN. We used 2 min applications at -85 degrees C at sites of the earliest atrial activation guided by activation mapping during isoprenaline infusion. Every application was preceded by high output stimulation to reveal phrenic nerve proximity. During the last application, heart rate slowly and persistently fell below 85 bpm despite isoprenaline infusion, but right diaphragmatic paralysis developed. At 6 months follow-up, the patient was asymptomatic and the diaphragmatic paralysis had partially resolved. This is the first report, we believe, of successful SN modification for IST by endocardial cryoablation, although this case also demonstrates the considerable risk of right phrenic nerve paralysis even with this ablation energy.

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Filhol, J. M.; Couprie, M. E.; Level, M. P.

    SOLEIL is a third generation Synchrotron radiation Source, under construction in France at St Aubin, near Paris. The Storage Ring consists in a 357 m circumference ring, with 16 cells and 24 straight sections (4x12m, 12x7m, 8x3.6m), out of which up to 21 will house insertion devices. The optics, with distributed dispersion, features a low 3.7 nm.rad emittance at the 2.75 GeV operating energy, so as to provide high brilliance, from the VUV up to the hard X ray domain. In order to provide a long lifetime, and beam position stabilities in the micron range, significant attention was paid atmore » each design stage (optics, magnets, beam position monitors, vacuum and RF systems,..), including the design of the building and infrastructure, the construction of which is now complete. This resulted in some unprecedented approaches such as the intensive use of NEG coating Aluminium vessels, or the development of a dedicated superconducting RF cavity and of 190 kW solid state RF amplifiers. The construction, started in 2002, is now completed. The injector system (100 MeV Linac) and the 3 Hz full energy Booster synchrotron have reached nominal operating conditions by fall 2005. The installation of the Storage Ring was just completed and its commissioning started in May 2006. First 9 turns in the ring were achieved on May the 14th, and visible synchrotron radiation was also observed on a CCD camera. Innovative insertion devices were designed and built so as to provide the best possible performances in an energy range as large as 5 eV to 20 keV. These are helical electromagnetic devices with 640 mm and 256 mm periods, APPLE II type undulators with 80 mm period, and in-vacuum hybrid undulators with 20 mm period. Two infra-red beamlines providing both edge and constant dipole field emission are also under construction and a superconducting wiggler is currently being designed in order to provide high flux in the 10 to 50 keV range. A first set of 10 beamlines (out of 24 included in the project) is being built and will be tested from summer 2006 onwards, with the aim of starting Users operation by the beginning of 2007.« less

  15. Status of the Commissioning of SOLEIL

    NASA Astrophysics Data System (ADS)

    Filhol, J. M.; Couprie, M. E.; Level, M. P.; Besson, J. C.; Brunelle, P.; Denard, J. C.; Godefroy, J. M.; Herbeaux, C.; Lebasque, P.; Le Roux, V.; Lestrade, A.; Loulergue, A.; Marchand, P.; Nadji, A.; Nadolski, L.; Nagaoka, R.; Pottin, B.; Tordeux, M. A.

    2007-01-01

    SOLEIL is a third generation Synchrotron radiation Source, under construction in France at St Aubin, near Paris. The Storage Ring consists in a 357 m circumference ring, with 16 cells and 24 straight sections (4×12m, 12×7m, 8×3.6m), out of which up to 21 will house insertion devices. The optics, with distributed dispersion, features a low 3.7 nm.rad emittance at the 2.75 GeV operating energy, so as to provide high brilliance, from the VUV up to the hard X ray domain. In order to provide a long lifetime, and beam position stabilities in the micron range, significant attention was paid at each design stage (optics, magnets, beam position monitors, vacuum and RF systems,..), including the design of the building and infrastructure, the construction of which is now complete. This resulted in some unprecedented approaches such as the intensive use of NEG coating Aluminium vessels, or the development of a dedicated superconducting RF cavity and of 190 kW solid state RF amplifiers. The construction, started in 2002, is now completed. The injector system (100 MeV Linac) and the 3 Hz full energy Booster synchrotron have reached nominal operating conditions by fall 2005. The installation of the Storage Ring was just completed and its commissioning started in May 2006. First 9 turns in the ring were achieved on May the 14th, and visible synchrotron radiation was also observed on a CCD camera. Innovative insertion devices were designed and built so as to provide the best possible performances in an energy range as large as 5 eV to 20 keV. These are helical electromagnetic devices with 640 mm and 256 mm periods, APPLE II type undulators with 80 mm period, and in-vacuum hybrid undulators with 20 mm period. Two infra-red beamlines providing both edge and constant dipole field emission are also under construction and a superconducting wiggler is currently being designed in order to provide high flux in the 10 to 50 keV range. A first set of 10 beamlines (out of 24 included in the project) is being built and will be tested from summer 2006 onwards, with the aim of starting Users operation by the beginning of 2007.

  16. EPICS controlled sample mounting robots at the GM/CA CAT.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Makarov, O. A.; Benn, R.; Corcoran, S.

    2007-11-11

    GM/CA CAT at Sector 23 of the advanced photon source (APS) is an NIH funded facility for crystallographic structure determination of biological macromolecules by X-ray diffraction [R.F. Fischetti, et al., GM/CA canted undulator beamlines for protein crystallography, Acta Crystallogr. A 61 (2005) C139]. The facility consists of three beamlines; two based on canted undulators and one on a bending magnet. The scientific and technical goals of the CAT emphasize streamlined, efficient throughput for a variety of sample types, sizes and qualities, representing the cutting edge of structural biology research. For this purpose all three beamlines are equipped with the ALS-stylemore » robots [C.W.Cork, et al. Status of the BCSB automated sample mounting and alignment system for macromolecular crystallography at the Advanced Light Source, SRI-2003, San-Francisco, CA, USA, August 25-29, 2003] for an automated mounting of cryo-protected macromolecular crystals. This report summarizes software and technical solutions implemented with the first of the three operational robots at beamline 23-ID-B. The automounter's Dewar can hold up to 72 or 96 samples residing in six Rigaku ACTOR magazines or ALS-style pucks, respectively. Mounting of a crystal takes approximately 2 s, during which time the temperature of the crystal is maintained near that of liquid nitrogen.« less

  17. [Impact of admission heart rate on short-term outcome of ST-elevation myocardial infarction patients].

    PubMed

    Zhang, Han; Yang, Yan-min; Zhu, Jun; Tan, Hui-qiong; Liu, Li-sheng

    2012-01-01

    To evaluate the impact of admission heart rate (HR) on 30-day all-cause death and cardiovascular events in Chinese patients with ST-elevation acute myocardial infarction (STEMI). A total of 7485 Chinese STEMI patients from a global randomized controlled trial (CREATE) database were divided into six groups by admission HR: < 60, 60 - 69, 70 - 79, 80 - 89, 90 - 99 and ≥ 100 bpm. The primary outcome was 30-day all-cause death; the secondary outcomes were the composite of 30-day all-cause death, reinfarction, cardiogenic shock or deadly arrhythmia. Admission glucose level, proportion of female gender, incidence of anterior myocardial infarction, previous diabetes mellitus, hypertension and Killip level II-IV were significantly higher in patients with admission HR ≥ 90 bpm compared to 60 - 69 bpm group (P < 0.05). The 30-day mortality was lowest (6.3%) in the 60 - 69 bpm group and was 9.6% in HR < 60 bpm group (P < 0.05 vs. 60 - 69 bpm group). In patients with admission HR > 60 bpm, the 30-day mortality increased in proportion to higher admission HR: 8.1% in 70 - 79 bpm, 9.2% in 80 - 89 bpm, 12.6% in 90 - 99 bpm and 24.6% in ≥ 100 bpm groups (all P < 0.05 vs. 60 - 69 bpm group). The incidence of MACE was similar as that of 30-day mortality: 27.0% in < 60 bpm, 12.5% in 60 - 69 bpm, 13.7% in 70 - 79 bpm, 14.3% in 80 - 89 bpm, 17.5% in 90 - 99 bpm and 31.1% in ≥ 100 bpm groups. Multivariate analysis showed that the incidence of 30-day mortality positively correlated with the admission HR (P < 0.05) except in the patients with admission HR < 60 bpm (OR = 0.832, P = 0.299), the risk of joint endpoint events was higher in the patients with HR < 60 bpm (OR = 1.532, 95%CI: 1.201 - 1.954, P < 0.05), 90 - 99 bpm (OR = 1.436, 95%CI: 1.091 - 1.889, P < 0.05) or ≥ 100 bpm (OR = 1.893, 95%CI: 1.471 - 2.436, P < 0.001). Admission HR is an independent risk factor for short-term outcome in Chinese STEMI patients.

  18. The Physics and Applications of High Brightness Electron Beams

    NASA Astrophysics Data System (ADS)

    Palumbo, Luigi; Rosenzweig, J.; Serafini, Luca

    2007-09-01

    Plenary sessions. RF deflector based sub-Ps beam diagnostics: application to FEL and advanced accelerators / D. Alesini. Production of fermtosecond pulses and micron beam spots for high brightness electron beam applications / S.G. Anderson ... [et al.]. Wakefields of sub-picosecond electron bunches / K.L.F. Bane. Diamond secondary emitter / I. Ben-Zvi ... [et al.]. Parametric optimization for an X-ray free electron laser with a laser wiggler / R. Bonifacio, N. Piovella and M.M. Cola. Needle cathodes for high-brightness beams / C.H. Boulware ... [et al.]. Non linear evolution of short pulses in FEL cascaded undulators and the FEL harmonic cascade / L. Giannessi and P. Musumeci. High brightness laser induced multi-meV electron/proton sources / D. Giulietti ... [et al.]. Emittance limitation of a conditioned beam in a strong focusing FEL undulator / Z. Huang, G. Stupakov and S. Reiche. Scaled models: space-charge dominated electron storage rings / R.A. Kishek ... [et al.]. High brightness beam applications: energy recovered linacs / G.A. Krafft. Maximizing brightness in photoinjectors / C. Limborg-Deprey and H. Tomizawa. Ultracold electron sources / O.J. Luiten ... [et al.]. Scaling laws of structure-based optical accelerators / A. Mizrahi, V. Karagodsky and L. Schächter. High brightness beams-applications to free-electron lasers / S. Reiche. Conception of photo-injectors for the CTF3 experiment / R. Roux. Superconducting RF photoinjectors: an overview / J. Sekutowicz. Status and perspectives of photo injector developments for high brightness beams / F. Stephan. Results from the UCLA/FNLP underdense plasma lens experiment / M.C. Thompson ... [et al.]. Medical application of multi-beam compton scattering monochromatic tunable hard X-ray source / M. Uesaka ... [et al.]. Design of a 2 kA, 30 fs RF-photoinjector for waterbag compression / S.B. Van Der Geer, O.J. Luiten and M.J. De Loos. Proposal for a high-brightness pulsed electron source / M. Zolotorev ... [et al.]. -- Working Group 1. Summary of working group 1 on electron sources / M. Ferrario and G. Gatti. Design and RF measurements of an X-band accelerating structure for the SPARC project / D. Alesini ... [et al.]. Mitigation of RF gun breakdown by removal of tuning rods in high field regions / A.M. Cook... [et al.]. Measurements of quantum efficiency of Mg films produced by pulsed laser ablation deposition for application to bright electron sources / G. Gatti ... [et al.]. The S-band 1.6 cell RF gun correlated energy spread dependence on Pi and 0 mode relative amplitude / F. Schmerge ... [et al.]. RF gun photo-emission model for metal cathodes including time dependent emission / J.F. Schmerge ... [et al.]. Superconducting photocathodes / J. Smedley ... [et al.]. -- Working Group 2. Summary of Working Group 2: diagnostics and beam manipulation / G. Travish. Observation of coherent edge radiation emitted by a 100 Femtosecond compressed electron beam / G. Andonian, M, Dunning, E. Hemsing, J. B. Rosenzweig ... [et al.]. PARMELA simulations for PITZ: first machine studies and interpretation of measurements / M. Boscolo ... [et al.]. The LCLS single-shot relative bunch length monitor system / M.P. Dunning ... [et al.]. Beam shaping and permanent magnet quadrupole focusing with applications to the plasma wakefield accelerator / R.J. England ... [et al.]. Commissioning of the SPARC movable emittance meter and its first operation at PITZ / D. Filippetto... [et al.]. Experimental testing of dynamically optimized photoelectron beams / J.B. Rosenzweig ... [et al.]. Synchronization between the laser and electron beam in a photocathode RF gun / A. Sakumi ... [et al.]. Method of bunch radiation photochronography with 10 Femtosecond and less resolution / A. Tron and I. Merinov -- Working Group 3. New challenges in theory and modeling-summary for working group 3. L. Giannessi. Resonant modes in a 1.6 cells RF gun / M. Ferrario and C. Ronsivalle. Emittance degradation due to wake fields in a high brightness photoinjector / M. Ferrario, V. Fusco, M. Migliorati and L. Palumbo. Simulations of coherent synchroton radiation effects in electron machines / M. Migliorati, A, Schiavi and G. Dattoli. QFEL: A numerical code for multi-dimensional simulation of free electron lasers in the quantum regime / A. Schiavi ... [et al.]. First simulations results on laser pulse jitter and microbunching instability at Saprxino / M. Boscolo ... [et al.]. -- Working Group 4. Working group 4 summary: applications of high brightness beams to advanced accelerators and light sources / M. Uesaka and A. Rossi. Study of transverse effects in the production of X-rays with free-electron laser based on an optical ondulator / A. Bacci ... [et al.]. Channeling projects at LNF: from crystal undulators to capillary waveguides / S.B. Dabagov ... [et al.]. Mono-Energetic electron generation and plasma diagnosis experiments in a laser plasma cathode / K. Kinoshita ... [et al.]. A high-density electron beam and quad-scan measurements at Pleiades Thompson X-ray source / J.K. Lim ... [et al.]. Laser pulse circulation system for compact monochromatic tunable hard X-ray source / H. Ogino ... [et al.]. Limits on production of narrow band photons from inverse compton scattering / J. Rosenzweig and O. Williams. Preliminary results from the UCLA/SLAC ultra-high gradient Cerenkov wakefield accelerator experiment / M.C. Thompson ... [et al.]. Status of the polarized nonlinear inverse compton scattering experiment at UCLA / O. Williams... [et al.]. Coupling laser power into a slab-symmetric accelerator structure / R.B. Yoder and J.B. Rosenzweig.

  19. THz and Sub-THz Capabilities of a Table-Top Radiation Source Driven by an RF Thermionic Electron Gun

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smirnov, Alexei V.; Agustsson, R.; Boucher, S.

    Design features and experimental results are presented for a sub-mm wave source [1] based on APS RF thermionic electron gun. The setup includes compact alpha-magnet, quadrupoles, sub-mm-wave radiators, and THz optics. The sub-THz radiator is a planar, oversized structure with gratings. Source upgrade for generation frequencies above 1 THz is discussed. The THz radiator will use a short-period undulator having 1 T field amplitude, ~20 cm length, and integrated with a low-loss oversized waveguide. Both radiators are integrated with a miniature horn antenna and a small ~90°-degree in-vacuum bending magnet. The electron beamline is designed to operate different modes includingmore » conversion to a flat beam interacting efficiently with the radiator. The source can be used for cancer diagnostics, surface defectoscopy, and non-destructive testing. Sub-THz experiment demonstrated a good potential of a robust, table-top system for generation of a narrow bandwidth THz radiation. This setup can be considered as a prototype of a compact, laser-free, flexible source capable of generation of long trains of Sub-THz and THz pulses with repetition rates not available with laser-driven sources.« less

  20. Safety of Landiolol Hydrochloride as a Premedication for Producing an Appropriate Heart Rate for Multidetector-Row Computed Tomography Coronary Angiography.

    PubMed

    Koyoshi, Rie; Shiga, Yuhei; Idemoto, Yoshiaki; Ueda, Yoko; Tashiro, Kohei; Kuwano, Takashi; Kitajima, Ken; Fujimi, Kanta; Kawamura, Akira; Ogawa, Masahiro; Miura, Shin-Ichiro

    2018-01-01

    We evaluated the safety of a bolus injection of landiolol hydrochloride, an ultrashort-acting β1-selective antagonist, as a premedication prior to multidetector-row computed tomography coronary angiography (CTA). The subjects consisted of 176 patients (M/F = 64:112, 67 ± 11 years) who had heart rate (HR) at rest ≥ 70 beats/min (bpm) and underwent CTA. Systolic/diastolic blood pressure (SBP/DBP) and HR were measured before and after the administration of landiolol. SBP/DBP and HR upon entry to the CT room were 136 ± 17/80 ± 11 mm Hg and 83 ± 10 bpm, respectively. HR was significantly reduced at the time of CTA scan (62 ± 7 bpm). Next, we divided the patients into three groups according to HR upon entry to the CT room: 70 - 79 bpm (n = 76), 80 - 89 bpm (n = 60) and ≥ 90 bpm (n = 40). HR at the time of CTA scan was significantly lower than that upon entry to the CT room in all three groups: 70 - 79 bpm (74 ± 3 bpm upon entry to the CT room to 61 ± 6 bpm at the time of CAT scan), 80 - 89 bpm (84 ± 3 to 63 ± 7 bpm) and ≥ 90 bpm (98 ± 6 to 65 ± 7 bpm). Although SBP/DBP was significantly decreased after the CTA scan (123 ± 18/72 ± 12 mm Hg), landiolol had no severe adverse events throughout CTA. In conclusion, a bolus injection of landiolol reduced HR by about 20 bpm without any severe adverse effects. Thus, a bolus injection of landiolol hydrochloride may be a suitable pretreatment for controlling HR in CTA.

  1. Scaffolding protein RanBPM and its interactions in diverse signaling pathways in health and disease.

    PubMed

    Das, Soumyadip; Haq, Saba; Ramakrishna, Suresh

    2018-04-01

    Ran-binding protein in the microtubule-organizing center (RanBPM) is an evolutionarily conserved, nucleocytoplasmic scaffolding protein involved in various cellular processes and several signal transduction pathways. RanBPM has a crucial role in mediating disease pathology by interacting with diverse proteins to regulate their functions. Previously, we compiled diverse cellular functions of RanBPM. Since then the functions of RanBPM have increased exponentially. In this article, we have updated the functions of RanBPM through its manifold interactions that have been investigated to date, according to their roles in protein stability, transcriptional activity, cellular development, neurobiology, and the cell cycle. Our review provides a complete guide on RanBPM interactors, the physiological role of RanBPM in cellular functions, and potential applications in disease therapeutics.

  2. Effect of Nebivolol on MIBG Parameters and Exercise in Heart Failure with Normal Ejection Fraction.

    PubMed

    Messias, Leandro Rocha; Ferreira, Aryanne Guimarães; Miranda, Sandra Marina Ribeiro de; Teixeira, José Antônio Caldas; Azevedo, Jader Cunha de; Messias, Ana Carolina Nader Vasconcelos; Maróstica, Elisabeth; Mesquita, Claudio Tinoco

    2016-05-01

    More than 50% of the patients with heart failure have normal ejection fraction (HFNEF). Iodine-123 metaiodobenzylguanidine (123I-MIBG) scintigraphy and cardiopulmonary exercise test (CPET) are prognostic markers in HFNEF. Nebivolol is a beta-blocker with vasodilating properties. To evaluate the impact of nebivolol therapy on CPET and123I-MIBG scintigraphic parameters in patients with HFNEF. Twenty-five patients underwent 123I-MIBG scintigraphy to determine the washout rate and early and late heart-to-mediastinum ratios. During the CPET, we analyzed the systolic blood pressure (SBP) response, heart rate (HR) during effort and recovery (HRR), and oxygen uptake (VO2). After the initial evaluation, we divided our cohort into control and intervention groups. We then started nebivolol and repeated the tests after 3 months. After treatment, the intervention group showed improvement in rest SBP (149 mmHg [143.5-171 mmHg] versus 135 mmHg [125-151 mmHg, p = 0.016]), rest HR (78 bpm [65.5-84 bpm] versus 64.5 bpm [57.5-75.5 bpm, p = 0.028]), peak SBP (235 mmHg [216.5-249 mmHg] versus 198 mmHg [191-220.5 mmHg], p = 0.001), peak HR (124.5 bpm [115-142 bpm] versus 115 bpm [103.7-124 bpm], p= 0.043), HRR on the 1st minute (6.5 bpm [4.75-12.75 bpm] versus 14.5 bpm [6.7-22 bpm], p = 0.025) and HRR on the 2nd minute (15.5 bpm [13-21.75 bpm] versus 23.5 bpm [16-31.7 bpm], p = 0.005), but no change in peak VO2 and 123I-MIBG scintigraphic parameters. Despite a better control in SBP, HR during rest and exercise, and improvement in HRR, nebivolol failed to show a positive effect on peak VO2 and 123I-MIBG scintigraphic parameters. The lack of effect on adrenergic activity may be the cause of the lack of effect on functional capacity.

  3. Ultra-High Accelerating Gradients in Radio-Frequency Cryogenic Copper Structures

    NASA Astrophysics Data System (ADS)

    Cahill, Alexander David

    Normal conducting radio-frequency (rf) particle accelerators have many applications, including colliders for high energy physics, high-intensity synchrotron light sources, non-destructive testing for security, and medical radiation therapy. In these applications, the accelerating gradient is an important parameter. Specifically for high energy physics, increasing the accelerating gradient extends the potential energy reach and is viewed as a way to mitigate their considerable cost. Furthermore, a gradient increase will enable for more compact and thus accessible free electron lasers (FELs). The major factor limiting larger accelerating gradients is vacuum rf breakdown. Basic physics of this phenomenon has been extensively studied over the last few decades. During which, the occurrence of rf breakdowns was shown to be probabilistic, and can be characterized by a breakdown rate. The current consensus is that vacuum rf breakdowns are caused by movements of crystal defects induced by periodic mechanical stress. The stress may be caused by pulsed surface heating and large electric fields. A compelling piece of evidence that supports this hypothesis is that accelerating structures constructed from harder materials exhibit larger accelerating gradients for similar breakdown rates. One possible method to increase sustained electric fields in copper cavities is to cool them to temperatures below 77 K, where the rf surface resistance and coefficient of thermal expansion decrease, while the yield strength (which correlates with hardness) and thermal conductivity increase. These changes in material properties at low temperature increases metal hardness and decreases the mechanical stress from exposure to rf electromagnetic fields. To test the validity of the improvement in breakdown rate, experiments were conducted with cryogenic accelerating cavities in the Accelerator Structure Test Area (ASTA) at SLAC National Accelerator Laboratory. A short 11.4 GHz standing wave accelerating structure was conditioned to an accelerating gradient of 250 MV/m at 45 K with 108 rf pulses. At gradients greater than 150 MV/m I observed a degradation in the intrinsic quality factor of the cavity, Q0. I developed a model for the change in Q0 using measured field emission currents and rf signals. I found that the Q 0 degradation is consistent with the rf power being absorbed by strong field emission currents accelerated inside the cavity. I measured rf breakdown rates for 45 K and found 2*10-4/pulse/meter when accounting for any change in Q0. These are the largest accelerating gradients for a structure with similar breakdown rates. The final chapter presents the design of an rf photoinjector electron source that uses the cryogenic normal conducting accelerator technology: the TOPGUN. With this cryogenic rf photoinjector, the beam brightness will increase by over an order of a magnitude when compared to the current photoinjector for the Linac Coherent Light Source (LCLS). When using the TOPGUN as the source for an X-ray Free Electron Laser, the higher brightness would allow for a decrease in the required length of the LCLS undulator by more than a factor of two.

  4. Bipyrimidine ruthenium(II) arene complexes: structure, reactivity and cytotoxicity.

    PubMed

    Betanzos-Lara, Soledad; Novakova, Olga; Deeth, Robert J; Pizarro, Ana M; Clarkson, Guy J; Liskova, Barbora; Brabec, Viktor; Sadler, Peter J; Habtemariam, Abraha

    2012-10-01

    The synthesis and characterization of complexes [(η(6)-arene)Ru(N,N')X][PF(6)], where arene is para-cymene (p-cym), biphenyl (bip), ethyl benzoate (etb), hexamethylbenzene (hmb), indane (ind) or 1,2,3,4-tetrahydronaphthalene (thn), N,N' is 2,2'-bipyrimidine (bpm) and X is Cl, Br or I, are reported, including the X-ray crystal structures of [(η(6)-p-cym)Ru(bpm)I][PF(6)], [(η(6)-bip)Ru(bpm)Cl][PF(6)], [(η(6)-bip)Ru(bpm)I][PF(6)] and [(η(6)-etb)Ru(bpm)Cl][PF(6)]. Complexes in which N,N' is 1,10-phenanthroline (phen), 1,10-phenanthroline-5,6-dione or 4,7-diphenyl-1,10-phenanthroline (bathophen) were studied for comparison. The Ru(II) arene complexes undergo ligand-exchange reactions in aqueous solution at 310 K; their half-lives for hydrolysis range from 14 to 715 min. Density functional theory calculations on [(η(6)-p-cym)Ru(bpm)Cl][PF(6)], [(η(6)-p-cym)Ru(bpm)Br][PF(6)], [(η(6)-p-cym)Ru(bpm)I][PF(6)], [(η(6)-bip)Ru(bpm)Cl][PF(6)], [(η(6)-bip)Ru(bpm)Br][PF(6)] and [(η(6)-bip)Ru(bpm)I][PF(6)] suggest that aquation occurs via an associative pathway and that the reaction is thermodynamically favourable when the leaving ligand is I > Br ≈ Cl. pK (a)* values for the aqua adducts of the complexes range from 6.9 to 7.32. A binding preference for 9-ethylguanine (9-EtG) compared with 9-ethyladenine (9-EtA) was observed for [(η(6)-p-cym)Ru(bpm)Cl][PF(6)], [(η(6)-hmb)Ru(bpm)Cl](+), [(η(6)-ind)Ru(bpm)Cl](+), [(η(6)-thn)Ru(bpm)Cl](+), [(η(6)-p-cym)Ru(phen)Cl](+) and [(η(6)-p-cym)Ru(bathophen)Cl](+) in aqueous solution at 310 K. The X-ray crystal structure of the guanine complex [(η(6)-p-cym)Ru(bpm)(9-EtG-N7)][PF(6)](2) shows multiple hydrogen bonding. Density functional theory calculations show that the 9-EtG adducts of all complexes are thermodynamically preferred compared with those of 9-EtA. However, the bmp complexes are inactive towards A2780 human ovarian cancer cells. Calf thymus DNA interactions for [(η(6)-p-cym)Ru(bpm)Cl][PF(6)] and [(η(6)-p-cym)Ru(phen)Cl][PF(6)] consist of weak coordinative, intercalative and monofunctional coordination. Binding to biomolecules such as glutathione may play a role in deactivating the bpm complexes.

  5. R&D for a Soft X-Ray Free Electron Laser Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Corlett, John; Attwood, David; Byrd, John

    2009-06-08

    Several recent reports have identified the scientific requirements for a future soft x-ray light source, and a high-repetition-rate free-electron laser (FEL) facility that is responsive to these requirements is now on the horizon. R&D in some critical areas is needed, however, to demonstrate technical performance, thus reducing technical risks and construction costs. Such a facility most likely will be based on a CW superconducting linear accelerator with beam supplied by a high-brightness, high-repetition-rate photocathode electron gun operating in CW mode, and on an array of FELs to which the accelerated beam is distributed, each operating at high repetition rate andmore » with even pulse spacing. Dependent on experimental requirements, the individual FELs can be configured for either self-amplified spontaneous emission (SASE), seeded, or oscillator mode of operation, including the use of high-gain harmonic generation (HGHG), echo-enhanced harmonic generation (EEHG), harmonic cascade, or other configurations. In this White Paper we identify the overall accelerator R&D needs, and highlight the most important pre-construction R&D tasks required to value-engineer the design configuration and deliverables for such a facility. In Section 1.4 we identify the comprehensive R&D ultimately needed. We identify below the highest-priority requirements for understanding machine performance and reduce risk and costs at this pre-conceptual design stage. Details of implementing the required tasks will be the subject of future evaluation. Our highest-priority R&D program is the injector, which must be capable of delivering a beam with bunches up to a nanocoulomb at MHz repetition rate and with normalized emittance {le} 1 mm {center_dot} mrad. This will require integrated accelerating structure, cathode, and laser systems development. Cathode materials will impact the choice of laser technology in wavelength and energy per pulse, as well as vacuum requirements in the accelerating structure. Demonstration experiments in advanced seeding techniques, such as EEHG, and other optical manipulations to enhance the FEL process are required to reduce technical risk in producing temporally coherent and ultrashort x-ray output using optical seed lasers. Success of EEHG in particular would result in reduced development and cost of laser systems and accelerator hardware for seeded FELs. With a 1.5-2.5 GeV linac, FELs could operate in the VUV-soft x-ray range, where the actual beam energy will be determined by undulator technology; for example, to use the lower energy would require the use of advanced designs for which undulator R&D is needed. Significant reductions in both unit costs and accelerator costs resulting from the lower electron beam energy required to achieve lasing at a particular wavelength could be obtained with undulator development. Characterization of the wakefields of the vacuum chambers in narrow-gap undulators will be needed to minimize risk in ability to deliver close to transform limited pulses. CW superconducting RF technology for an FEL facility with short bunches at MHz rate and up to mA average current will require selection of design choices in cavity frequency and geometry, higher order mode suppression and power dissipation, RF power supply and distribution, accelerating gradient, and cryogenics systems. R&D is needed to define a cost and performance optimum. Developments in laser technology are proceeding at rapid pace, and progress in high-power lasers, harmonic generation, and tunable sources will need to be tracked.« less

  6. Resting Bradycardia, Enhanced Postexercise Heart Rate Recovery and Cardiorespiratory Fitness in Recreational Ballroom Dancers.

    PubMed

    Cruz, Carlos Janssen Gomes da; Molina, Guilherme Eckhardt; Porto, Luiz Guilherme Grossi; Junqueira, Luiz Fernando

    2017-09-01

    In a cross-sectional study design, we evaluated the resting heart rate (HR baseline ) and exercise and postexercise stress test-related chronotropic responses in male practitioners of recreational ballroom dancing (BD; n = 25, M age = 26.6 ± 6.1 years) compared to a control group of insufficiently active nondancers (CG; n = 25, M age = 25.9 ± 4.5 years). All participants underwent a submaximal exercise test. At 85% of the maximal predicted HR, the recovery protocol was started, and heart rate recovery (HRR) was recorded during 1-min intervals for 5 min. Compared with CG, BD showed lower HR baseline (70 beats per minute [bpm] vs. 62 bpm, respectively, U = 143, p < .05, ES = .46), lower preexercise HR (94 bpm vs. 86 bpm, U = 157, p < .05, ES = .42), longer exercise test duration (346 s vs. 420 s, U = 95.5, p < .05, ES = .59), and higher HRR for 5 min postexercise (U = 1.29-1.89, p < .05, ES = .33-.50) as follows: 1st min (32 bpm vs. 40 bpm), 2nd min (45 bpm vs. 53 bpm), 3rd min (51 bpm vs. 58 bpm), 4th min (55 bpm vs. 59 bpm), and 5th min (59 bpm vs. 63 bpm). The coefficient of HRR from the 1st min to the 5th min postexercise was similar in both groups (U = 229-311, p > .05, ES = < .10-.22). Heightened cardiovascular functional status characterized by favorable enhanced chronotropic dynamics appears to occur in practitioners of recreational ballroom dancing, which suggests that this modality of exercise may result in health benefits.

  7. Blood pressure measurement in obese patients: comparison between upper arm and forearm measurements.

    PubMed

    Pierin, Angela M G; Alavarce, Débora C; Gusmão, Josiane L; Halpern, Alfredo; Mion, Décio

    2004-06-01

    It is well known that blood pressure measurement with a standard 12-13 cm wide cuff is erroneous for large arms. To compare arm blood pressure measurements with an appropriate cuff and forearm blood pressure measurements (BPM) with a standard cuff, and both measurements by the Photopletismography (Finapres) method. One hundred and twenty-nine obese patients were studied (body mass index=40+/-7 kg/m2). The patients had three arm BPM taken by an automatic oscillometric device using an appropriate cuff and three forearm BPM with a standard cuff in the sitting position after a five-minute rest. Data were analysed by the analysis of variance. The correction values were obtained by the linear regression test. Systolic and diastolic arm BPM with an appropriate cuff were significantly lower (p<0.05) than forearm BPM with a standard cuff. The measurements obtained by Finapres were significantly lower (p<0.05) than those found for forearm systolic and diastolic blood pressures and upper arm diastolic blood pressure. The equation to correct BPM in forearm in obese patients with arm circumference between 32-44 cm was: systolic BPM=33.2+/-0.68 x systolic forearm BPM, and diastolic BPM=25.2+0.59 x forearm diastolic BPM. This study showed that forearm blood pressure measurement overestimates the values of arm blood pressure measurement. In addition, it is possible to correct forearm BPM with an equation.

  8. BPM 3.0

    NASA Astrophysics Data System (ADS)

    Scheer, August-Wilhelm; Klueckmann, Joerg

    Business Process Management (BPM) is an established management discipline. Since today’s organizations expect every employee to think and act like an entrepreneur, i.e., like a manager, BPM is also increasingly becoming part of everyday operations. But merely adopting a process-based approach across the enterprise is not enough to enable BPM at every level. What is needed is a combination of organizational forms and technologies that support distributed BPM initiatives while simultaneously consolidating them company-wide. Every employee must be empowered to model and optimize their own processes. At the same time, the entire BPM community needs a platform that brings together all the individual initiatives. This is the only way to leverage the full potential of process-oriented management. In the following article, the authors describe the trends in BPM development that are turning users into process managers and supporting the creation of a BPM community.

  9. Measurement and Compensation of BPM Chamber Motion in HLS

    NASA Astrophysics Data System (ADS)

    Li, J. W.; Sun, B. G.; Cao, Y.; Xu, H. L.; Lu, P.; Li, C.; Xuan, K.; Wang, J. G.

    2010-06-01

    Significant horizontal drifts in the beam orbit in the storage ring of HLS (Hefei Light Source) have been seen for many years. What leads to the motion of Beam Position Monitor (BPM) chamber is thermal expansion mainly caused by the synchrotron light. To monitor the BPM chamber motions for all BPMs, a BPM chamber motion measurement system is built in real-time. The raster gauges are used to measure the displacements. The results distinctly show the relation between the BPM chamber motion and the beam current. To suppress the effect of BPM chamber motion, a compensation strategy is implemented at HLS. The horizontal drifts of beam orbit have been really suppressed within 20μm without the compensation of BPM chamber motion in the runtime.

  10. Measurement and Compensation of BPM Chamber Motion in HLS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, J. W.; Sun, B. G.; Cao, Y.

    2010-06-23

    Significant horizontal drifts in the beam orbit in the storage ring of HLS (Hefei Light Source) have been seen for many years. What leads to the motion of Beam Position Monitor (BPM) chamber is thermal expansion mainly caused by the synchrotron light. To monitor the BPM chamber motions for all BPMs, a BPM chamber motion measurement system is built in real-time. The raster gauges are used to measure the displacements. The results distinctly show the relation between the BPM chamber motion and the beam current. To suppress the effect of BPM chamber motion, a compensation strategy is implemented at HLS.more » The horizontal drifts of beam orbit have been really suppressed within 20{mu}m without the compensation of BPM chamber motion in the runtime.« less

  11. Diagnosing Postural Tachycardia Syndrome: Comparison of Tilt Test versus Standing Hemodynamics

    PubMed Central

    Plash, Walker B; Diedrich, André; Biaggioni, Italo; Garland, Emily M; Paranjape, Sachin Y; Black, Bonnie K; Dupont, William D; Raj, Satish R

    2012-01-01

    Postural tachycardia syndrome (POTS) is characterized by increased heart rate (ΔHR) of ≥30 bpm with symptoms related to upright posture. Active stand (STAND) and passive head-up tilt (TILT) produce different physiological responses. We hypothesized these different responses would affect the ability of individuals to achieve the POTS HR increase criterion. Patients with POTS (n=15) and healthy controls (n=15) underwent 30 min of TILT and STAND testing. ΔHR values were analyzed at 5 min intervals. Receiver Operating Characteristics analysis was performed to determine optimal cut point values of ΔHR for both TILT and STAND. TILT produced larger ΔHR than STAND for all 5 min intervals from 5 min (38±3 bpm vs. 33±3 bpm; P=0.03) to 30 min (51±3 bpm vs. 38±3 bpm; P<0.001). Sensitivity (Sn) of the 30 bpm criterion was similar for all tests (TILT-10=93%, STAND-10=87%, TILT30=100%, and STAND30=93%). Specificity (Sp) of the 30 bpm criterion was less at both 10 and 30 min for TILT (TILT10=40%, TILT30=20%) than STAND (STAND10=67%, STAND30=53%). The optimal ΔHR to discriminate POTS at 10 min were 38 bpm (TILT) and 29 bpm (STAND), and at 30 min were 47 bpm (TILT) and 34 bpm (STAND). Orthostatic tachycardia was greater for TILT (with lower specificity for POTS diagnosis) than STAND at 10 and 30 min. The 30 bpm ΔHR criterion is not suitable for 30 min TILT. Diagnosis of POTS should consider orthostatic intolerance criteria and not be based solely on orthostatic tachycardia regardless of test used. PMID:22931296

  12. Diagnosing postural tachycardia syndrome: comparison of tilt testing compared with standing haemodynamics.

    PubMed

    Plash, Walker B; Diedrich, André; Biaggioni, Italo; Garland, Emily M; Paranjape, Sachin Y; Black, Bonnie K; Dupont, William D; Raj, Satish R

    2013-01-01

    POTS (postural tachycardia syndrome) is characterized by an increased heart rate (ΔHR) of ≥30 bpm (beats/min) with symptoms related to upright posture. Active stand (STAND) and passive head-up tilt (TILT) produce different physiological responses. We hypothesized these different responses would affect the ability of individuals to achieve the POTS HR increase criterion. Patients with POTS (n=15) and healthy controls (n=15) underwent 30 min of tilt and stand testing. ΔHR values were analysed at 5 min intervals. ROC (receiver operating characteristic) analysis was performed to determine optimal cut point values of ΔHR for both tilt and stand. Tilt produced larger ΔHR than stand for all 5 min intervals from 5 min (38±3 bpm compared with 33±3 bpm; P=0.03) to 30 min (51±3 bpm compared with 38±3 bpm; P<0.001). Sn (sensitivity) of the 30 bpm criterion was similar for all tests (TILT10=93%, STAND10=87%, TILT30=100%, and STAND30=93%). Sp (specificity) of the 30 bpm criterion was less at both 10 and 30 min for tilt (TILT10=40%, TILT30=20%) than stand (STAND10=67%, STAND30=53%). The optimal ΔHR to discriminate POTS at 10 min were 38 bpm (TILT) and 29 bpm (STAND), and at 30 min were 47 bpm (TILT) and 34 bpm (STAND). Orthostatic tachycardia was greater for tilt (with lower Sp for POTS diagnosis) than stand at 10 and 30 min. The 30 bpm ΔHR criterion is not suitable for 30 min tilt. Diagnosis of POTS should consider orthostatic intolerance criteria and not be based solely on orthostatic tachycardia regardless of test used.

  13. Heart rate at baseline influences the effect of ivabradine on cardiovascular outcomes in chronic heart failure: analysis from the SHIFT study.

    PubMed

    Böhm, Michael; Borer, Jeffrey; Ford, Ian; Gonzalez-Juanatey, Jose R; Komajda, Michel; Lopez-Sendon, Jose; Reil, Jan-Christian; Swedberg, Karl; Tavazzi, Luigi

    2013-01-01

    We analysed the effect of ivabradine on outcomes in heart failure (HF) patients on recommended background therapies with heart rates ≥75 bpm and <75 bpm in the SHIFT trial. A cut-off value of ≥75 bpm was chosen by the EMEA for approval for the use of ivabradine in chronic heart failure. The SHIFT population was divided by baseline heart rate ≥75 or <75 bpm. The effect of ivabradine was analysed for primary composite endpoint (cardiovascular death or HF hospitalization) and other endpoints. In the ≥75 bpm group, ivabradine reduced primary endpoint (HR 0.76, 95 % CI 0.68-0.85, P < 0.0001), all-cause mortality (HR 0.83, 95 % CI, 0.72-0.96, P = 0.0109), cardiovascular mortality (HR 0.83, 95 % CI, (0.71-0.97, P = 0.0166), HF death (HR 0.61, 95 % CI, 0.46-0.81, P < 0.0006), and HF hospitalization (HR 0.70, 95 % CI, 0.61-0.80, P < 0.0001). Risk reduction depended on heart rate after 28 days, with the best protection for heart rates <60 bpm or reductions >10 bpm. None of the endpoints was significantly reduced in the <75 bpm group, though there were trends for risk reductions in HF death and hospitalization for heart rate <60 bpm and reductions >10 bpm. Ivabradine was tolerated similarly in both groups. The effect of ivabradine on outcomes is greater in patients with heart rate ≥75 bpm with heart rates achieved <60 bpm or heart rate reductions >10 bpm predicting best risk reduction. Our findings emphasize the importance of identification of high-risk HF patients by high heart rates and their treatment with heart rate-lowering drugs such as ivabradine.

  14. Self-propelled swimming simulations of bio-inspired smart structures.

    PubMed

    Daghooghi, Mohsen; Borazjani, Iman

    2016-08-09

    This paper presents self-propelled swimming simulations of a foldable structure, whose folded configuration is a box. For self-locomotion through water the structure unfolds and undulates. To guide the design of the structure and understand how it should undulate to achieve either highest speed or maximize efficiency during locomotion, several kinematic parameters were systematically varied in the simulations: the wave type (standing wave versus traveling wave), the smoothness of undulations (smooth undulations versus undulations of rigid links), the mode of undulations (carangiform: mackerel-like versus anguilliform: eel-like undulations), and the maximum amplitude of undulations. We show that the swimmers with standing wave are slow and inefficient because they are not able to produce thrust using the added-mass mechanism. Among the tested types of undulation at low Reynolds number (Re) regime of [Formula: see text] (Strouhal number of about 1.0), structures that employ carangiform undulations can swim faster, whereas anguilliform swimmers are more economic, i.e., using less power they can swim a longer distance. Another finding of our simulations is that structures which are made of rigid links are typically less efficient (lower propulsive and power efficiencies and also lower swimming speed) compared with smoothly undulating ones because a higher added-mass force is generated by smooth undulations. The wake of all the swimmers bifurcated at the low Re regime because of the higher lateral relative to the axial velocity (high Strouhal number) that advects the vortices laterally creating a double row of vortices in the wake. In addition, we show that the wake cannot be used to predict the performance of the swimmers because the net force in each cycle is zero for self-propelled bodies and the pressure term is not negligible compared to the other terms.

  15. Quality of life among patients after bilateral prophylactic mastectomy: a systematic review of patient-reported outcomes.

    PubMed

    Razdan, Shantanu N; Patel, Vishal; Jewell, Sarah; McCarthy, Colleen M

    2016-06-01

    Bilateral prophylactic mastectomy (BPM) is effective in reducing the risk of breast cancer in women with a well-defined family history of breast cancer or in women with BRCA 1 or 2 mutations. Evaluating patient-reported outcomes following BPM are thus essential for evaluating success of BPM from patient's perspective. Our systematic review aimed to: (1) identify studies describing health-related quality of life (HRQOL) in patients following BPM with or without reconstruction; (2) assess the effect of BPM with or without reconstruction on HRQOL; and (3) identify predictors of HRQOL post-BPM. We performed a systematic review of literature using the PRISMA guidelines. PubMed, Embase, PsycINFO, Web of Science, Scopus and Cochrane databases were searched. The initial search resulted in 1082 studies; 22 of these studies fulfilled our inclusion criteria. Post-BPM, patients are satisfied with the outcomes and report high psychosocial well-being and positive body image. Sexual well-being and somatosensory function are most negatively affected. Vulnerability, psychological distress and preoperative cancer distress are significant negative predictors of quality of life and body image post-BPM. There is a paucity of high-quality data on outcomes of different HRQOL domains post-BPM. Future studies should strive to use validated and breast-specific PRO instruments for measuring HRQOL. This will facilitate shared decision-making by enabling surgeons to provide evidence-based answers to women contemplating BPM.

  16. Towards a typology of business process management professionals: identifying patterns of competences through latent semantic analysis

    NASA Astrophysics Data System (ADS)

    Müller, Oliver; Schmiedel, Theresa; Gorbacheva, Elena; vom Brocke, Jan

    2016-01-01

    While researchers have analysed the organisational competences that are required for successful Business Process Management (BPM) initiatives, individual BPM competences have not yet been studied in detail. In this study, latent semantic analysis is used to examine a collection of 1507 BPM-related job advertisements in order to develop a typology of BPM professionals. This empirical analysis reveals distinct ideal types and profiles of BPM professionals on several levels of abstraction. A closer look at these ideal types and profiles confirms that BPM is a boundary-spanning field that requires interdisciplinary sets of competence that range from technical competences to business and systems competences. Based on the study's findings, it is posited that individual and organisational alignment with the identified ideal types and profiles is likely to result in high employability and organisational BPM success.

  17. Design and cold test of S-BAND cavity BPM for HLS

    NASA Astrophysics Data System (ADS)

    Luo, Qing; Sun, BaoGen; Jia, QiKa; He, DuoHui; Fang, Jia

    2011-12-01

    An S-band cavity BPM is designed for a new injector in National Synchrotron Radiation Laboratory. A re-entrant position cavity is tuned to the TM110 mode as position cavity. Cut-through waveguides are used as pickups to suppress the monopole signal. Theoretical resolution of this design is 31 nm. A prototype cavity BPM system is manufactured for off-line cold tests. The wire scanning method is used to calibrate the BPM and estimate the performance of the on-line BPM system. A cross-talk problem has been detected during the cold test. Racetrack cavity BPM design can be used to suppress the cross-talk. With the nonlinear effect being ignored, transform matrix can be used to correct cross-talk. Analysis of cold test results shows that the position resolution of prototype BPM is better than 3 μm.

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tsuchiya, Kimichika, E-mail: kimichika.tsuchiya@kek.jp; Adachi, Masahiro; Shioya, Tatsuro

    At the 2.5-GeV Photon Factory (PF) storage ring, we recently constructed four new undulators known as U#02-2, U#13, SGU#15, and U#28 for BL02, BL13, BL15, and BL28, respectively. SGU#15 is an in-vacuum undulator with a period length of 17.6 mm. The other three undulators are elliptically polarizing undulators (EPUs) for the vacuum ultraviolet and soft X-ray (VUV-SX) light sources to obtain various polarization states. We constructed these new undulators by fiscal 2013 and step by step installed them in the PF ring. We describe the details of the construction of these new undulators in this report.

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    WATANABE, T.; LIU, D.; MURPHY, J.B.

    The strong focusing VISA undulator is presented in this report. The proposed FEL will operate at the 1 {micro}m water window. Extensive simulations were performed to optimize an FEL amplifier based on the two-meter long VISA undulator which has a period of 1.8 cm and an undulator parameter K = 1.26. The betatron function inside the VISA undulator is about 30 cm. For an electron beam with a peak current {approx}1 kA and a normalized emittance of 5 mm-mrad, the FEL peak power can exceed 1 GW within the 2 m VISA undulator using a 5 kW peak power seedmore » laser. Such a device can produce a megawatt of average power for a 700 MHz rep rate. The transverse distribution of the FEL radiation along the undulator, as well as after the undulator, is explored by numerical simulation. The FEL power density at 5 m downstream from the undulator is less than 100 kW/cm{sup 2} for this MW-class FEL. We will also discuss the feasibility of an experimental demonstration of the laser seeded FEL amplifier based on the 2-m VISA undulator at the NSLS Source Development Lab (SDL).« less

  20. Compact Undulator for the Cornell High Energy Synchrotron Source: Design and Beam Test Results

    NASA Astrophysics Data System (ADS)

    Temnykh, A.; Dale, D.; Fontes, E.; Li, Y.; Lyndaker, A.; Revesz, P.; Rice, D.; Woll, A.

    2013-03-01

    We developed, built and beam tested a novel, compact, in-vacuum undulator magnet based on an adjustable phase (AP) scheme. The undulator is 1 m long with a 5mm gap. It has a pure permanent magnet structure with 24.4mm period and 1.1 Tesla maximum peak field. The device consists of two planar magnet arrays mounted on rails inside of a rectangular box-like frame with 156 mm × 146 mm dimensions. The undulator magnet is enclosed in a 273 mm (10.75") diameter cylindrical vacuum vessel with a driver mechanism placed outside. In May 2012 the CHESS Compact Undulator (CCU) was installed in Cornell Electron Storage Ring and beam tested. During four weeks of dedicated run we evaluated undulator radiation properties as well as magnetic, mechanical and vacuum properties of the undulator magnet. We also studied the effect of the CCU on storage ring beam. The spectral characteristics and intensity of radiation were found to be in very good agreement with expected. The magnet demonstrated reproducibility of undulator parameter K at 1.4 × 10-4 level. It was also found that the undulator K. parameter change does not affect electron beam orbit and betatron tunes.

  1. BioCARS: a synchrotron resource for time-resolved X-ray science

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Graber, T.; Anderson, S.; Brewer, H.

    2011-08-16

    BioCARS, a NIH-supported national user facility for macromolecular time-resolved X-ray crystallography at the Advanced Photon Source (APS), has recently completed commissioning of an upgraded undulator-based beamline optimized for single-shot laser-pump X-ray-probe measurements with time resolution as short as 100 ps. The source consists of two in-line undulators with periods of 23 and 27 mm that together provide high-flux pink-beam capability at 12 keV as well as first-harmonic coverage from 6.8 to 19 keV. A high-heat-load chopper reduces the average power load on downstream components, thereby preserving the surface figure of a Kirkpatrick-Baez mirror system capable of focusing the X-ray beammore » to a spot size of 90 {micro}m horizontal by 20 {micro}m vertical. A high-speed chopper isolates single X-ray pulses at 1 kHz in both hybrid and 24-bunch modes of the APS storage ring. In hybrid mode each isolated X-ray pulse delivers up to {approx}4 x 10{sup 10} photons to the sample, thereby achieving a time-averaged flux approaching that of fourth-generation X-FEL sources. A new high-power picosecond laser system delivers pulses tunable over the wavelength range 450-2000 nm. These pulses are synchronized to the storage-ring RF clock with long-term stability better than 10 ps RMS. Monochromatic experimental capability with Biosafety Level 3 certification has been retained.« less

  2. BioCARS: a synchrotron resource for time-resolved X-ray science

    PubMed Central

    Graber, T.; Anderson, S.; Brewer, H.; Chen, Y.-S.; Cho, H. S.; Dashdorj, N.; Henning, R. W.; Kosheleva, I.; Macha, G.; Meron, M.; Pahl, R.; Ren, Z.; Ruan, S.; Schotte, F.; Šrajer, V.; Viccaro, P. J.; Westferro, F.; Anfinrud, P.; Moffat, K.

    2011-01-01

    BioCARS, a NIH-supported national user facility for macromolecular time-resolved X-ray crystallography at the Advanced Photon Source (APS), has recently completed commissioning of an upgraded undulator-based beamline optimized for single-shot laser-pump X-ray-probe measurements with time resolution as short as 100 ps. The source consists of two in-line undulators with periods of 23 and 27 mm that together provide high-flux pink-beam capability at 12 keV as well as first-harmonic coverage from 6.8 to 19 keV. A high-heat-load chopper reduces the average power load on downstream components, thereby preserving the surface figure of a Kirkpatrick–Baez mirror system capable of focusing the X-ray beam to a spot size of 90 µm horizontal by 20 µm vertical. A high-speed chopper isolates single X-ray pulses at 1 kHz in both hybrid and 24-bunch modes of the APS storage ring. In hybrid mode each isolated X-ray pulse delivers up to ∼4 × 1010 photons to the sample, thereby achieving a time-averaged flux approaching that of fourth-generation X-FEL sources. A new high-power picosecond laser system delivers pulses tunable over the wavelength range 450–2000 nm. These pulses are synchronized to the storage-ring RF clock with long-term stability better than 10 ps RMS. Monochromatic experimental capability with Biosafety Level 3 certification has been retained. PMID:21685684

  3. Development and fabrication of the vacuum systems for an elliptically polarized undulator at Taiwan Photon Source

    NASA Astrophysics Data System (ADS)

    Chang, Chin-Chun; Chan, Che-Kai; Wu, Ling-Hui; Shueh, Chin; Shen, I.-Ching; Cheng, Chia-Mu; Yang, I.-Chen

    2017-05-01

    Three sets of a vacuum system were developed and fabricated for elliptically polarized undulators (EPU) of a 3-GeV synchrotron facility. These chambers were shaped with low roughness extrusion and oil-free machining; the design combines aluminium and stainless steel. The use of a bimetallic material to connect the EPU to the vacuum system achieves the vacuum sealing and to resolve the leakage issue due to bake process induced thermal expansion difference. The interior of the EPU chamber consists of a non-evaporable-getter strip pump in a narrow space to absorb photon-stimulated desorption and to provide a RF bridge design to decrease impedance effect in the two ends of EPU chamber. To fabricate these chambers and to evaluate the related performance, we performed a computer simulation to optimize the structure. During the machining and welding, the least deformation was achieved, less than 0.1 mm near 4 m. In the installation, the linear slider can provide a stable and precision moved along parallel the electron beam direction smoothly for the EPU chamber to decrease the twist issue during baking process. The pressure of the EPU chamber attained less than 2×10-8 Pa through baking. These vacuum systems of the EPU magnet have been installed in the electron storage ring of Taiwan Photon Source in 2015 May and have normally operated at 300 mA continuously since, and to keep beam life time achieved over than 12 h.

  4. Development of a BPM Lock-In Diagnostic System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Richard Dickson

    2003-05-12

    A system has been developed for the acquisition and analysis of high rate, time coherent BPM data across the Jefferson Lab's Continuous Electron Beam Accelerator Facility (CEBAF). This system will allow the acquisition of Beam Position Monitor (BPM) position and intensity information at a rate in excess 7 KHz for approximately 200 BPMs in a time synchronous manner. By inducing minute sinusoidal transverse beam motion in the CEBAF injector, with known phase relative to the synchronized BPM acquisition, it is possible to derive several types of useful information. Analysis of the BPM intensity data, which is proportional to beam current,more » by beating the signal with an in-phase sinusoidal representation of the transverse kick can localize beam scraping to a particular BPM. Similarly, real-time optics information may be deduced with an analysis of BPM position data. This paper will detail the frequency lock-in technique applied and present status.« less

  5. Leap-frog-based BPM (LF-BPM) method for solving nanophotonic structures

    NASA Astrophysics Data System (ADS)

    Ayoub, Ahmad B.; Swillam, Mohamed A.

    2018-02-01

    In this paper, we propose an efficient approach to solve the BPM equation. By splitting the complex field into real and imaginary parts, the method is proved to be at least 30% faster than the conventional BPM. This method was tested on several optical components to test the accuracy.

  6. Simulations of laser undulators

    NASA Astrophysics Data System (ADS)

    Milton, S. V.; Biedron, S. B.; Einstein, J. E.

    2016-09-01

    We perform a series of single-pass, one-D free-electron laser simulations based on an electron beam from a standard linear accelerator coupled with a so-called laser undulator, a specialized device that is more compact than a standard undulator based on magnetic materials. The longitudinal field profiles of such lasers undulators are intriguing as one must and can tailor the profile for the needs of creating the virtual undulator. We present and discuss several results of recent simulations and our future steps.

  7. The plasma undulator

    NASA Astrophysics Data System (ADS)

    Fedele, R.; Vaccaro, V. G.; Miano, G.

    1990-01-01

    The use of a large-amplitude plasma wave as an electrostatic undulator is presently analyzed on the basis of the existing theory of FEL magnetic undulator devices. An account is given of prospective plasma-undulator configurations; it is noted that very small wavelength electromagnetic radiation can be generated through the use of low energy electron beams. Thresholds for the plasma undulator-employing FEL action are discussed, and an analysis of the intrinsic efficiency of such a device is conducted with a view to its emittance and wake-field effects.

  8. Preliminary evidence for good psychometric properties of the Norwegian version of the Brief Problems Monitor (BPM).

    PubMed

    Richter, Jörg

    2015-04-01

    Methods to assess intervention progress and outcome for frequent use are needed. To provide preliminary information about psychometric properties for the Norwegian version of the Brief Problems Monitor. Cronbach's alpha scores and intra-class correlation coefficients as indicators for internal consistency (reliability) and Pearson correlation coefficients between corresponding subscales of the long and short ASEBA form versions as well as multiple regression coefficients to explore the predictive power of the reduced item-set related to the corresponding scale-scores of the long version were calculated in large, representative data sets of Norwegian children and adolescents. Cronbach's alpha scores of the Norwegian version of the BPM subscales varied between 0.67 (attention BPM-youth) and 0.88 (attention BPM-teacher) and between 0.90 (BPM-youth) and 0.96 (BPM-teacher) for its total problem score. Corresponding subscales from the long versions and the BPM as well as the total problems scores were closely correlated with coefficients of high effect size (all r > 0.80). The variance of the items of the BPM explained about three-quarters or more of the variance in the corresponding subscales of the long version. The Norwegian BPM has good psychometric properties in terms of 1) being acceptable to good internal consistency and in terms of 2) regression coefficients of high effect size from the BPM items to the problem-scale scores of the long versions as validity indicators. Its use in clinical practice and research can be recommended.

  9. The relationship between admission heart rate and early prognosis in patients with ST-elevation myocardial infarction.

    PubMed

    Salwa, Paweł; Gorczyca-Michta, Iwona; Wożakowska-Kapłon, Beata

    2015-01-01

    Heart rate (HR) is a basic cardiovascular parameter. The relationship between HR and cardiovascular mortality and morbidity has been indicated in clinical trials and epidemiological studies. The evaluation of the relationship between HR upon hospital admission and the in-hospital prognosis in a group of patients with ST-elevation myocardial infarction (STEMI). The medical records of 927 patients were subject to retrospective analysis. The patients were classified on the basis of HR upon hospital admission: < 60 bpm (n = 75), 60-69 bpm (n = 169), 70-79 bpm (n = 245), 80-89 bpm (n = 172), 90-99 bpm (n = 134), and ≥ 100 bpm (n = 132). A group of patients with HR of 60-69 bpm on hospital admission (n = 169) constituted a reference group. Patients with atrioventricular blocks and arrhythmias were excluded from the analysis. Early mortality and co-existing diseases were evaluated in the study population. Patients with HR ≥ 90 bpm demonstrated heart failure symptoms considerably more often than patients with HR of 60-69 bpm (p = 0.0010). In-hospital mortality was significantly higher in patients with a HR of more than 90 bpm and bradycardia. The relationship between HR and cardiovascular mortality is shown with a J-shaped curve. HR is strictly correlated with early cardiovascular mortality in a population of patients with STEMI. The relationship between HR and early mortality is demonstrated by a J-shaped curve.

  10. Quality of life among patients after bilateral prophylactic mastectomy: A systematic review of patient reported outcomes

    PubMed Central

    Razdan, Shantanu N.; Patel, Vishal; Jewell, Sarah; McCarthy, Colleen M.

    2016-01-01

    Purpose Bilateral prophylactic mastectomy (BPM) is effective in reducing the risk of breast cancer in women with a well-defined family history of breast cancer or in women with BRCA 1 or 2 mutations. Evaluating patient-reported outcomes following BPM are thus essential for evaluating success of BPM from patient’s perspective. Our systematic review aimed to: (1) identify studies describing health-related quality of life (HRQOL) in patients following BPM with or without reconstruction; (2) assess the effect of BPM with or without reconstruction on HRQOL; and, (3) identify predictors of HRQOL post BPM. Methods We performed a systematic review of literature using the PRISMA guidelines. PubMed, Embase, PsycINFO, Web of Science, Scopus and Cochrane databases were searched. Results The initial search resulted in 1082 studies; 22 of these studies fulfilled our inclusion criteria. Post BPM, patients are satisfied with the outcomes and report high psychosocial well-being and positive body image. Sexual well-being and somatosensory function are most negatively affected. Vulnerability, psychological distress and preoperative cancer distress are significant negative predictors of quality of life and body image post BPM. Conclusion There is a paucity of high quality data on outcomes of different HRQOL domains post BPM. Future studies should strive to use validated and breast-specific PRO instruments for measuring HRQOL. This will facilitate shared decision-making by enabling surgeons to provide evidence-based answers to women contemplating BPM. PMID:26577764

  11. Admission Systolic Blood Pressure Predicts the Number of Blood Pressure Medications at Discharge in Patients With Primary Intracerebral Hemorrhage.

    PubMed

    Khawaja, Ayaz M; Shiue, Harn; Boehme, Amelia K; Albright, Karen C; Venkatraman, Anand; Kumar, Gyanendra; Lyerly, Michael J; Hays-Shapshak, Angela; Mirza, Maira; Gropen, Toby I; Harrigan, Mark R

    2018-03-01

    Control of systolic blood pressure (SBP) after primary intracerebral hemorrhage improves outcomes. Factors determining the number of blood pressure medications (BPM) required for goal SBP<160 mm Hg at discharge are unknown. We hypothesized that higher admission-SBPs require a greater number of BPM for goal discharge-SBP<160 mm Hg, and investigated factors influencing this goal. We conducted a retrospective review of 288 patients who presented with primary intracerebral hemorrhage. Admission-SBP was obtained. Primary outcome was the number of BPM at discharge. Comparison was made between patients presenting with and without a history of hypertension, and patients discharged on <3 and ≥3 BPM. Patients with hypertension history had a higher median admission-SBP compared with those without (180 vs. 157 mm Hg, P=0.0001). In total, 133 of 288 (46.2%) patients were discharged on <3 BPM; 155/288 (53.8%) were discharged on ≥3 BPM. Hypertension history (P<0.0001) and admission-SBP (P<0.0001) predicted the number of BPM at discharge. In patients without hypertension history, every 10 mm Hg increase in SBP resulted in an absolute increase of 0.5 BPM at discharge (P=0.0011), whereas in those with hypertension, the absolute increase was 1.3 BPM (P=0.0012). In comparison with patients discharged on <3 BPM, patients discharged on ≥3 BPM were more likely to have a higher median admission-SBP, be younger in age, belong to the African-American race, have a history of diabetes, have higher median admission-National Institutes of Health Stroke Scale and modified Rankin Scale of 4 to 5 at discharge. An understanding of the factors influencing BPM at discharge may help clinicians better optimize blood pressure control both before and after discharge.

  12. Retrospective Evaluation of the Effect of Heart Rate on Survival in Dogs with Atrial Fibrillation.

    PubMed

    Pedro, B; Dukes-McEwan, J; Oyama, M A; Kraus, M S; Gelzer, A R

    2018-01-01

    Atrial fibrillation (AF) usually is associated with a rapid ventricular rate. The optimal heart rate (HR) during AF is unknown. Heart rate affects survival in dogs with chronic AF. Forty-six dogs with AF and 24-hour ambulatory recordings were evaluated. Retrospective study. Holter-derived HR variables were analyzed as follows: mean HR (meanHR, 24-hour average), minimum HR (minHR, 1-minute average), maximum HR (maxHR, 1-minute average). Survival times were recorded from the time of presumed adequate rate control. The primary endpoint was all-cause mortality. Cox proportional hazards analysis identified variables independently associated with survival; Kaplan-Meier survival analysis estimated the median survival time of dogs with meanHR <125 bpm versus ≥125 bpm. All 46 dogs had structural heart disease; 31 of 46 had congestive heart failure (CHF), 44 of 46 received antiarrhythmic drugs. Of 15 dogs with cardiac death, 14 had CHF. Median time to all-cause death was 524 days (Interquartile range (IQR), 76-1,037 days). MeanHR was 125 bpm (range, 62-203 bpm), minHR was 82 bpm (range, 37-163 bpm), maxHR was 217 bpm (range, 126-307 bpm). These were significantly correlated with all-cause and cardiac-related mortality. For every 10 bpm increase in meanHR, the risk of all-cause mortality increased by 35% (hazard ratio, 1.35; 95% CI, 1.17-1.55; P < 0.001). Median survival time of dogs with meanHR<125 bpm (n = 23) was significantly longer (1,037 days; range, 524-open) than meanHR ≥125 bpm (n = 23; 105 days; range, 67-267 days; P = 0.0012). Mean HR was independently associated with all-cause and cardiovascular mortality (P < 0.003). Holter-derived meanHR affects survival in dogs with AF. Dogs with meanHR <125 bpm lived longer than those with meanHR ≥ 125 bpm. Copyright © 2017 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  13. Concept of quasi-periodic undulator - control of radiation spectrum

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sasaki, Shigemi

    1995-02-01

    A new type of undulator, the quasi-periodic undulator (QPU) is considered which generates the irrational harmonics in the radiation spectrum. This undulator consists of the arrays of magnet blocks aligned in a quasi-periodic order, and consequentially lead to a quasi-periodic motion of electron. A combination of the QPU and a conventional crystal/grating monochromator provides pure monochromatic photon beam for synchrotron radiation users because the irrational harmonics do not be diffracted in the same direction by a monochromator. The radiation power and width of each radiation peak emitted from this undulator are expected to be comparable with those of the conventionalmore » periodic undulator.« less

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Libkind, M.; Bertolini, L.; Duffy, P.

    As part of the research and development effort for a 4th generation light source, we have designed a 4-meter long Free-Electron Laser (FEL) undulator. The undulator will be installed at the Accelerator Test Facility (ATF) at Brookhaven National Laboratory to conduct a Self-Amplified Spontaneous Emission (SASE) demonstration. The demonstration is called VISA, which stands for "Visible to Infrared SASE Amplifier." The undulator consists of 440 permanent dipole magnets per meter which are supported and aligned on a precision strongback. Focusing and defocusing permanent quadrupole magnets are also supported by the strongback. Each of the 4 one-meter sections of undulator aremore » kinematically supported and housed within the vacuum vessel. The undulator and the vacuum vessel are supported independently to eliminate undulator misalignment during vacuum pump-down of the vessel. We describe the design requirements and features of the undulator, vacuum vessel and support system.« less

  15. Gelatinous fibers and variant secondary growth related to stem undulation and contraction in a monkey ladder vine, Bauhinia glabra (Fabaceae).

    PubMed

    Fisher, Jack B; Blanco, Mario A

    2014-04-01

    Some of the most striking stem shapes occur in species of Bauhinia (Fabaceae) known as monkey ladder vines. Their mature stems are flattened and develop regular undulations. Although stems have variant (anomalous) secondary growth, the mechanism causing the undulations is unknown. We measured stem segments over time (20 mo), described stem development using light microscopy, and correlated the changes in stem shape with anatomy. Growing stems are initially straight and bear tendrils on short axillary branches. The inner secondary xylem has narrow vessels and lignified fibers. As stems age, they become flattened and increasingly undulated with the production of two lobes of outer secondary xylem (OX) with wide vessels and only gelatinous fibers (G-fibers). Similar G-fibers are present in the secondary phloem and the cortical sclerified layer. In transverse sections, the concave side of each undulation has a greater area and quantity of G-fibers than the opposite convex side. Some older stems are not undulated and have less lobing of OX. Undulation causes a shortening of the stem segments: up to 28% of the original length. Uneven distribution of G-fibers produces tensions that are involved in the protracted development of undulations. While young extending shoots attach by lateral branch tendrils, older stems may maintain their position in the canopy using undulations and persistent branch bases as gripping devices. Flattened and undulated stems with G-fibers produce flexible woody stems.

  16. Difference between BPM reading one bunch and the average of multi-bunch in Booster

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xi Yang

    2004-08-18

    Differences caused by BPM reading one bunch and multi-bunch average need to be well understood before the beam parameters, such as the synchrotron tune, betatron tune, and chromaticity, are extracted from those BPM data. It is easy to perform such a study using numerical simulation other than modifying the BPM electronics.

  17. Helical undulator based on partial redistribution of uniform magnetic field

    NASA Astrophysics Data System (ADS)

    Balal, N.; Bandurkin, I. V.; Bratman, V. L.; Fedotov, A. E.

    2017-12-01

    A new type of helical undulator based on redistribution of magnetic field of a solenoid by ferromagnetic helix has been proposed and studied both in theory and experiment. Such undulators are very simple and efficient for promising sources of coherent spontaneous THz undulator radiation from dense electron bunches formed in laser-driven photo-injectors.

  18. Radiation characteristics and polarisation of undulated microstrip line antennas

    NASA Astrophysics Data System (ADS)

    Shafai, L.; Sebak, A. A.

    1985-12-01

    A numerical method is used to investigate the radiation from undulated microstrip line antennas. The undulated line is assumed to be suspended over a ground plane and its current distribution is determined using a moment method type solution. This current distribution is then used to compute the co-polar and cross-polar radiation fields. It is found that the current distribution has an oscillating behavior along the line, with a frequency which is twice the number of undulations. The cross-polarization is found to be high and relatively independent of the undulating shape. Its relative level, however, is reduced for large arrays, due to the array factor affecting the co-polar field. A procedure for the reduction or elimination of the cross-polarization is then proposed, which is based on utilizing two undulated lines with mutually inverted undulations. A design method for achieving low sidelobe levels is also proposed and a design example with sidelobes around the -40 dB range is presented.

  19. Using Shoulder Straps Decreases Heart Rate Variability and Salivary Cortisol Concentration in Swedish Ambulance Personnel.

    PubMed

    Karlsson, Kåre J; Niemelä, Patrik H; Jonsson, Anders R; Törnhage, Carl-Johan A

    2016-03-01

    Previous research has shown that paramedics are exposed to risks in the form of injuries to the musculoskeletal system. In addition, there are studies showing that they are also at increased risk of cardiovascular disease, cancer, and psychiatric diseases, which can partly be explained by their constant exposure to stress. The aim of this study is to evaluate whether the use of shoulder straps decreases physical effort in the form of decreased heart rate and cortisol concentration. A stretcher with a dummy was carried by 20 participants for 400 m on two occasions, one with and one without the shoulder straps. Heart rate was monitored continuously and cortisol samples were taken at intervals of 0 minutes, 15 minutes, 30 minutes, 45 minutes, and 60 minutes. Each participant was her or his own control. A significant decrease in heart rate and cortisol concentration was seen when shoulder straps were used. The median values for men (with shoulder straps) at 0 minutes was 78 bpm/21.1 nmol/L (heart rate/cortisol concentration), at 15 minutes was 85 bpm/16.9 nmol/L, and at 60 minutes was 76 bpm/15.7 nmol/L; for men without shoulder straps, these values were 78 bpm/21.9 nmol/L, 93 bpm/21.9 nmol/L, and 73 bpm/20.5 nmol/L. For women, the values were 85 bpm/23.3 nmol/L, 92 bpm/20.8 nmol/L, and 70 bpm/18.4 nmol/L and 84 bpm/32.4 nmol/L, 100 bpm/32.5 nmol/L, and 75 bpm/25.2 nmol/L, respectively. The use of shoulder straps decreases measurable physical stress and should therefore be implemented when heavy equipment or a stretcher needs to be carried. An easy way to ensure that staff use these or similar lifting aids is to provide them with personalized, well-adapted shoulder straps. Another better option would be to routinely sewn these straps into the staff's personal alarm jackets so they are always in place and ready to be used.

  20. Effect of station-specific alerting and ramp-up tones on firefighters' alarm time heart rates.

    PubMed

    MacNeal, James J; Cone, David C; Wistrom, Christopher L

    2016-11-01

    A number of long-term health effects are suffered by emergency responders, some influenced by psychological stress and fatigue. This study explored if stress and fatigue can be reduced by changing the method by which firefighters are alerted to emergency responses. Over several months, the method by which responders at a fire department were alerted was altered. Firefighter heart rates were measured first with standard alerting as a control (phase 1: all stations alerted simultaneously, with high-volume tones). The department then implemented station-specific (phase 2) and gradual volume ramp-up (phase 3) tone alerting, and heart rate increases were compared. The Fatigue Severity Score was used to examine firefighter fatigue, and the department administered a follow-up survey on personnel preferences. Individual heart rate increases (Δbpm) ranged from 2-48 bpm. Median increases were 7 bpm (IQR 4-11 bpm) during phase 1 (72.2% of alarms Δbpm<10), 7 bpm (IQR 5-12 bpm) during phase 2 (60.7% of alarms Δbpm<10), and 5 bpm (IQR 3-8 bpm) during phase 3 (82.7% of alarms Δbpm<10). The difference in medians was lower for phases 1 and 2 than for phase 3 (p = 0.0069), and more alarms in phase 3 resulted in increases of <10 bpm than in phase 2 (p = 0.0089). The Fatigue Severity Scale showed little variability: median scores 7 in phase 1, 8 in phase 2, and 7 in phase 3. Firefighters reported a strong preference for the "ramp-up" tones, and were roughly evenly divided between preferring alerting all stations simultaneously 24/7 (40% rating this 4 or 5 on a five-point Likert scale), station-specific alerting 24/7 (47.5%), or all stations during the day but station-specific at night (40%). Ramp-up tones were perceived as the best method to reduce stress during the day and overnight. Small but significant decreases in the amount of tachycardic response to station alerting are associated with simple alterations in alerting methods. Station-specific and ramp-up tones improve perceived working conditions for emergency responders.

  1. DEVELOPMENT OF SHORT UNDULATORS FOR ELECTRON-BEAM-RADIATION INTERACTION STUDIES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Piot, P.; Andorf, M. B.; Fagerberg, G.

    Interaction of an electron beam with external field or its own radiation has widespread applications ranging from coherent-radiation generation, phase space cooling or formation of temporally-structured beams. An efficient coupling mechanism between an electron beam and radiation field relies on the use of a magnetic undulator. In this contribution we detail our plans to build short (11-period) undulators with 7-cm period refurbishing parts of the aladdin U3 undulator [1]. Possible use of these undulators at available test facilities to support experiments relevant to cooling techniques and radiation sources are outlined.

  2. Stimulatory effect on rat thymocytes proliferation and antimicrobial activity of two 6-(propan-2-yl)-4-methyl-morpholine-2,5-diones.

    PubMed

    Pavlovic, Voja; Djordjevic, Aleksandra; Cherneva, Emiliya; Yancheva, Denitsa; Smelcerovic, Andrija

    2012-03-01

    Recently we reported the identification and synthesis of cyclodidepsipeptides, 3,6-di(propan-2-yl)-4-methyl-morpholine-2,5-dione (PPM) and 3-(2-methylpropyl)-6-(propan-2-yl)-4-methyl-morpholine-2,5-dione (BPM), as potential precursors of enniatin B in Fusarium sporotrichioides. No data concerning biological activity of PPM and BPM have hitherto been published. The possible immunomodulatory effect and antimicrobial activity of PPM and BPM were investigated in this study, due to well known biological activities of enniatin B. The cytotoxicity effect of PPM and BPM on rat thymocytes demonstrated that increasing concentrations (0.1, 1, 10 μg/well) of PPM and BPM to cell culture, showed no significant effect on thymocytes toxicity. Simultaneously, incubation with studied cyclodidepsipeptides did not result with decreased mitochondrial membrane potential. Further, thymocytes exposure to increasing concentration of PPM and BPM was not able to induce significant reactive oxygen species (ROS) production in rat thymocytes. PPM and BPM administrations to cell culture in concentrations of 0.1 and 1 μg/well resulted with no significant increase of proliferative activity. However, significantly increased proliferative activity was detected with 10 μg of PPM (p<0.001) and BPM (p<0.05), as compared to their respective controls. The in vitro antimicrobial activity of PPM and BPM was tested against two Gram-positive and three Gram-negative bacteria. The results indicated that MIC values against tested strains ranged between 2.00 and 25.00 mg/ml. PPM showed much better activity against all tested bacteria in comparison with BPM. PPM was equally effective against both Gram-positive and Gram-negative bacteria, at the dose of 2.00 mg/ml. Copyright © 2011 Elsevier Ltd. All rights reserved.

  3. Spinal Cord Injury Impairs Cardiovascular Capacity in Elite Wheelchair Rugby Athletes.

    PubMed

    Gee, Cameron M; Currie, Katharine D; Phillips, Aaron A; Squair, Jordan W; Krassioukov, Andrei V

    2017-12-19

    To examine differences in heart rate (HR) responses during international wheelchair rugby competition between athletes with and without a cervical spinal cord injury (SCI) and across standardized sport classifications. Observational study. The 2015 Parapan American Games wheelchair rugby competition. Forty-three male athletes (31 ± 8 years) with a cervical SCI (n = 32) or tetraequivalent impairment (non-SCI, n = 11). Average and peak HR (HRavg and HRpeak, respectively). To characterize HR responses in accordance with an athletes' International Wheelchair Rugby Federation (IWRF) classification, we separated athletes into 3 groups: group I (IWRF classification 0.5-1.5, n = 15); group II (IWRF classification 2.0, n = 15); and group III (IWRF classification 2.5-3.5, n = 13). Athletes with SCI had lower HRavg (111 ± 14 bpm vs 155 ± 13 bpm) and HRpeak (133 ± 12 bpm vs 178 ± 13 bpm) compared with non-SCI (both P < 0.001). Average HR was higher in group III than in I (136 ± 25 bpm vs 115 ± 20 bpm, P = 0.045); however, SCI athletes showed no difference in HRavg or HRpeak between groups. Within group III, SCI athletes had lower HRavg (115 ± 6 bpm vs 160 ± 8 bpm) and HRpeak (135 ± 11 bpm vs 183 ± 11 bpm) than non-SCI athletes (both P < 0.001). This study is the first to demonstrate attenuated HR responses during competition in SCI compared with non-SCI athletes, likely due to injury to spinal autonomic pathways. Among athletes with SCI, IWRF classification was not related to differences in HR. Specific assessment of autonomic function after SCI may be able to predict HR during competition and consideration of autonomic impairments may improve the classification process.

  4. Effects of smoking on heart rate at rest and during exercise, and on heart rate recovery, in young adults.

    PubMed

    Papathanasiou, George; Georgakopoulos, Dimitris; Papageorgiou, Effie; Zerva, Efthimia; Michalis, Lampros; Kalfakakou, Vasiliki; Evangelou, Angelos

    2013-01-01

    There is an established link between smoking, abnormal heart rate (HR) values, and impaired cardiovascular health in middle-aged or older populations. The purpose of this study was to examine the effects of smoking on resting HR and on HR responses during and after exercise in young adults. A sample of 298 young adults (159 men), aged 20-29 years old, were selected from a large population of health-science students based on health status, body mass index, physical activity, and smoking habit. All subjects underwent a maximal Bruce treadmill test and their HR was recorded during, at peak, and after termination of exercise. Smokers had significantly higher resting HR values than non-smokers. Both female and male smokers showed a significantly slower HR increase during exercise. Female smokers failed to reach their age-predicted maximum HR by 6.0 bpm and males by 3.6 bpm. The actual maximum HR achieved (HRmax) was significantly lower for both female smokers (191.0 bpm vs.198.0 bpm) and male smokers (193.2 bpm vs.199.3 bpm), compared to non-smokers. Heart rate reserve was also significantly lower in female (114.6 bpm vs. 128.1 bpm) and male smokers (120.4 bpm vs. 133.0 bpm). During recovery, the HR decline was significantly attenuated, but only in female smokers. Females had a higher resting HR and showed a higher HR response during sub-maximal exercise compared to males. Smoking was found to affect young smokers' HR, increasing HR at rest, slowing HR increase during exercise and impairing their ability to reach the age-predicted HRmax. In addition, smoking was associated with an attenuated HR decline during recovery, but only in females.

  5. Using the nonlinear control of anaesthesia-induced hypersensitivity of EEG at burst suppression level to test the effects of radiofrequency radiation on brain function

    PubMed Central

    Lipping, Tarmo; Rorarius, Michael; Jäntti, Ville; Annala, Kari; Mennander, Ari; Ferenets, Rain; Toivonen, Tommi; Toivo, Tim; Värri, Alpo; Korpinen, Leena

    2009-01-01

    Background In this study, investigating the effects of mobile phone radiation on test animals, eleven pigs were anaesthetised to the level where burst-suppression pattern appears in the electroencephalogram (EEG). At this level of anaesthesia both human subjects and animals show high sensitivity to external stimuli which produce EEG bursts during suppression. The burst-suppression phenomenon represents a nonlinear control system, where low-amplitude EEG abruptly switches to very high amplitude bursts. This switching can be triggered by very minor stimuli and the phenomenon has been described as hypersensitivity. To test if also radio frequency (RF) stimulation can trigger this nonlinear control, the animals were exposed to pulse modulated signal of a GSM mobile phone at 890 MHz. In the first phase of the experiment electromagnetic field (EMF) stimulation was randomly switched on and off and the relation between EEG bursts and EMF stimulation onsets and endpoints were studied. In the second phase a continuous RF stimulation at 31 W/kg was applied for 10 minutes. The ECG, the EEG, and the subcutaneous temperature were recorded. Results No correlation between the exposure and the EEG burst occurrences was observed in phase I measurements. No significant changes were observed in the EEG activity of the pigs during phase II measurements although several EEG signal analysis methods were applied. The temperature measured subcutaneously from the pigs' head increased by 1.6°C and the heart rate by 14.2 bpm on the average during the 10 min exposure periods. Conclusion The hypothesis that RF radiation would produce sensory stimulation of somatosensory, auditory or visual system or directly affect the brain so as to produce EEG bursts during suppression was not confirmed. PMID:19615084

  6. Postural tachycardia syndrome: time frequency mapping

    NASA Technical Reports Server (NTRS)

    Novak, V.; Novak, P.; Opfer-Gehrking, T. L.; Low, P. A.

    1996-01-01

    Orthostatic tachycardia is common but its specificity remains uncertain. Our preliminary work suggested that using autonomic function testing in conjunction with time-frequency mapping (TFM), it might be possible to characterize a subset of the postural tachycardia syndrome (POTS), that is due to a restricted autonomic neuropathy. We describe 20 patients (17 women and 3 men, aged 14-43 years) with florid POTS and 20 controls (14 women and 6 men, aged 20-41 years). Autonomic failure was quantified by its distribution (cardiovagal, adrenergic and sudomotor) and severity, a symptom profile was generated, and spectral indices, based on modified Wigner distribution during rest and head-up tilt (80 degrees) were evaluated. During tilt-up POTS patients differed from controls by an excessive heart rate (> 130 bpm) (P < 0.001), and higher diastolic pressure (P < 0.01). During rest, cardiovagal oscillations (at respiratory frequencies [RF]) and slow rhythms at nonrespiratory frequencies (NONRF) (from 0.01 to 0.07 Hz) in R-R intervals (RRI) (P < 0.01) were reduced. Both RF and NONRF rhythms in RRI were further blunted with tilt-up (P < 0.001). Slow adrenergic vasomotor rhythms in blood pressure (BP) (approximately 0.07 Hz) surged with tilt-up and returned to normal levels afterwards. The index of sympatho-vagal balance (NONRF-Systolic BP (SBP)/RF-RRI) was dramatically increased in POTS (P < 0.001). Distal postganglionic sudomotor failure was observed, and impairment of the BP responses to the Valsalva maneuver (phase II) suggested peripheral adrenergic dysfunction. Persistent orthostatic dizziness, tiredness, gastrointestinal symptoms and palpitations were common in POTS patients. It is possible to identify a subset of POTS patients who have a length-dependent autonomic neuropathy, affecting the peripheral adrenergic and cardiovagal fibers, with relative preservation of cardiac adrenergic fibers.

  7. Process-aware EHR BPM systems: two prototypes and a conceptual framework.

    PubMed

    Webster, Charles; Copenhaver, Mark

    2010-01-01

    Systematic methods to improve the effectiveness and efficiency of electronic health record-mediated processes will be key to EHRs playing an important role in the positive transformation of healthcare. Business process management (BPM) systematically optimizes process effectiveness, efficiency, and flexibility. Therefore BPM offers relevant ideas and technologies. We provide a conceptual model based on EHR productivity and negative feedback control that links EHR and BPM domains, describe two EHR BPM prototype modules, and close with the argument that typical EHRs must become more process-aware if they are to take full advantage of BPM ideas and technology. A prediction: Future extensible clinical groupware will coordinate delivery of EHR functionality to teams of users by combining modular components with executable process models whose usability (effectiveness, efficiency, and user satisfaction) will be systematically improved using business process management techniques.

  8. Evaluation of in-hospital electrocardiography versus 24-hour Holter for rate control in dogs with atrial fibrillation.

    PubMed

    Gelzer, A R; Kraus, M S; Rishniw, M

    2015-07-01

    To determine if the in-clinic ECG-derived heart rate could predict the at-home Holter-derived 24-hour average heart rate (Holter24h ), and whether it is useful to identify slow versus fast atrial fibrillation in dogs. 82 pairs of 1-minute ECGs and 24-hour Holter recordings were acquired in 34 dogs with atrial fibrillation. The initial 24-hour Holter was used to test if the ECG heart rate can identify dogs with "slow" versus "fast" atrial fibrillation based on a Holter24h threshold value of 140 bpm. ECG heart rate overestimated Holter24h by 26 bpm (95% CI: 3 bpm, 48 bpm; P < 0 · 015) with a 95% limit of agreement of -21 to 83 bpm. The in-clinic ECG-derived heart rate Ä155 bpm had a sensitivity of 73% and a specificity of 100% for identifying a Holter24h HR Ä140 bpm; an in-clinic ECG-derived HR <160 bpm had a sensitivity and specificity of 91% each. In-clinic ECG assessment of heart rate in dogs with atrial fibrillation does not reliably predict the heart rate in their home environment. However, an in-clinic heart rate greater than 155 bpm is useful in identifying "fast" atrial fibrillation, allowing clinicians to stratify which case may benefit from antiarrhythmic therapy. © 2015 British Small Animal Veterinary Association.

  9. INTRA-UNDULATOR MEASUREMENTS AT VISA FEL.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    MUROKH,A.; FRIGOLA,P.; ET AL

    2000-08-13

    We describe a diagnostics system developed, to measure exponential gain properties and the electron beam dynamics inside the strong focusing 4-m long undulator for the VISA (Visible to Infrared SASE Amplifier) FEL. The technical challenges included working inside the small undulator gap, optimizing the electron beam diagnostics in the high background environment of the spontaneous undulator radiation, multiplexing and transporting the photon beam. Initial results are discussed.

  10. Intra-undulator measurements at VISA FEL

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Murokh, A; Frigola, P; Pellegrini, C

    2000-08-10

    We describe a diagnostics system developed, to measure exponential gain properties and the electron beam dynamics inside the strong focusing 4-m long undulator for the VISA (Visible to Infrared SASE Amplifier) FEL. The technical challenges included working inside the small undulator gap, optimizing the electron beam diagnostics in the high background environment of the spontaneous undulator radiation, multiplexing and transporting the photon beam. Initial results are discussed.

  11. Synthesis, structure, and magnetic properties of regular alternating μ-bpm/di-μ-X copper(II) chains (bpm = 2,2'-bipyrimidine; X = OH, F).

    PubMed

    Marino, Nadia; Armentano, Donatella; De Munno, Giovanni; Cano, Joan; Lloret, Francesc; Julve, Miguel

    2012-04-02

    The preparation and X-ray crystal structure of four 2,2'-bipyrimidine (bpm)-containing copper(II) complexes of formula {[Cu(2)(μ-bpm)(H(2)O)(4)(μ-OH)(2)][Mn(H(2)O)(6)](SO(4))(2)}(n) (1), {[Cu(2)(μ-bpm)(H(2)O)(4)(μ-OH)(2)]SiF(6)}(n) (2), {Cu(2)(μ-bpm)(H(2)O)(2)(μ-F)(2)F(2)}(n) (3), and [Cu(bpm)(H(2)O)(2)F(NO(3))][Cu(bpm)(H(2)O)(3)F]NO(3)·2H(2)O (4) are reported. The structures of 1-3 consist of chains of copper(II) ions with regular alternation of bis-bidentate bpm and di-μ-hydroxo (1 and 2) or di-μ-fluoro (3) groups, the electroneutrality being achieved by either hexaaqua manganese(II) cations plus uncoordinated sulfate anions (1), uncoordinated hexafluorosilicate anions (2), or terminally bound fluoride ligands (3). Each copper(II) ion in 1-4 is six-coordinated in elongated octahedral surroundings. 1 and 2 show identical, linear chain motifs with two bpm-nitrogen atoms and two hydroxo groups building the equatorial plane at each copper(II) ion and the axial position being filled by water molecules. In the case of 3, the axial sites at the copper atom are occupied by a bpm-nitrogen atom and a bis-monodentate fluoride anion, producing a "step-like" chain motif. The values of the angle at the hydroxo and fluoro bridges are 94.11(6) (1), 94.75(4) (2), and 101.43(4)° (3). In each case, the copper-copper separation through the bis-bidentate bpm [5.428(1) (1), 5.449(1) (2), and 5.9250(4) Å (3)] is considerably longer than that through the di-μ-hydroxo [2.8320(4) (1) and 2.824(1) Å (2)] or di-μ-fluoro [3.3027(4) Å (3)] bridges. Compound 4 is a mononuclear species whose structure is made up of neutral [Cu(bpm)(H(2)O)(2)F(NO(3))] units, [Cu(bpm)(H(2)O)(3)F](+) cations, uncoordinated nitrate anions, and crystallization water molecules, giving rise to a pseudo-helical, one-dimensional (1D) supramolecular motif. The magnetic properties of 1-3 have been investigated in the temperature range 1.9-300 K. Relatively large, alternating antiferro- [J = -149 (1) and -141 cm(-1) (2) across bis-bidentate bpm] and ferromagnetic [αJ = +194 (1) and +176 cm(-1) (2) through the dihydroxo bridges] interactions occur in 1 and 2 [the Hamiltonian being defined as H = -J∑(i=1)(n/2) (S(2i)·S(2i-1) - αS(2i)·S(2i+1))]. These values compare well with those previously reported for parent examples. Two weak intrachain antiferromagnetic interactions [J = -0.30 and αJ = -8.1 cm(-1) across bpm and the di-μ-fluoro bridges, respectively] whose values were substantiated by density functional theory (DFT)-type calculations occur in 3.

  12. Marine Geoid Undulation Assessment Over South China Sea Using Global Geopotential Models and Airborne Gravity Data

    NASA Astrophysics Data System (ADS)

    Yazid, N. M.; Din, A. H. M.; Omar, K. M.; Som, Z. A. M.; Omar, A. H.; Yahaya, N. A. Z.; Tugi, A.

    2016-09-01

    Global geopotential models (GGMs) are vital in computing global geoid undulations heights. Based on the ellipsoidal height by Global Navigation Satellite System (GNSS) observations, the accurate orthometric height can be calculated by adding precise and accurate geoid undulations model information. However, GGMs also provide data from the satellite gravity missions such as GRACE, GOCE and CHAMP. Thus, this will assist to enhance the global geoid undulations data. A statistical assessment has been made between geoid undulations derived from 4 GGMs and the airborne gravity data provided by Department of Survey and Mapping Malaysia (DSMM). The goal of this study is the selection of the best possible GGM that best matches statistically with the geoid undulations of airborne gravity data under the Marine Geodetic Infrastructures in Malaysian Waters (MAGIC) Project over marine areas in Sabah. The correlation coefficients and the RMS value for the geoid undulations of GGM and airborne gravity data were computed. The correlation coefficients between EGM 2008 and airborne gravity data is 1 while RMS value is 0.1499.In this study, the RMS value of EGM 2008 is the lowest among the others. Regarding to the statistical analysis, it clearly represents that EGM 2008 is the best fit for marine geoid undulations throughout South China Sea.

  13. Plasma channel undulator excited by high-order laser modes

    DOE PAGES

    Wang, J. W.; Schroeder, C. B.; Li, R.; ...

    2017-12-04

    The possibility of utilizing plasma undulators and plasma accelerators to produce compact ultraviolet and X-ray sources, has attracted considerable interest for a few decades. This interest has been driven by the great potential to decrease the threshold for accessing such sources, which are mainly provided by a few dedicated large-scale synchrotron or free-electron laser (FEL) facilities. However, the broad radiation bandwidth of such plasma devices limits the source brightness and makes it difficult for the FEL instability to develop. Here in this paper, using multi-dimensional particle-in-cell (PIC) simulations, we demonstrate that a plasma undulator generated by the beating of amore » mixture of high-order laser modes propagating inside a plasma channel, leads to a few percent radiation bandwidth. The strength of the undulator can reach unity, the period can be less than a millimeter, and the number of undulator periods can be significantly increased by a phase locking technique based on the longitudinal tapering. Polarization control of such an undulator can be achieved by appropriately choosing the phase of the modes. According to our results, in the fully beam loaded regime, the electron current in the plasma undulator can reach 0.3 kA level, making such an undulator a potential candidate towards a table-Top FEL.« less

  14. Plasma channel undulator excited by high-order laser modes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, J. W.; Schroeder, C. B.; Li, R.

    The possibility of utilizing plasma undulators and plasma accelerators to produce compact ultraviolet and X-ray sources, has attracted considerable interest for a few decades. This interest has been driven by the great potential to decrease the threshold for accessing such sources, which are mainly provided by a few dedicated large-scale synchrotron or free-electron laser (FEL) facilities. However, the broad radiation bandwidth of such plasma devices limits the source brightness and makes it difficult for the FEL instability to develop. Here in this paper, using multi-dimensional particle-in-cell (PIC) simulations, we demonstrate that a plasma undulator generated by the beating of amore » mixture of high-order laser modes propagating inside a plasma channel, leads to a few percent radiation bandwidth. The strength of the undulator can reach unity, the period can be less than a millimeter, and the number of undulator periods can be significantly increased by a phase locking technique based on the longitudinal tapering. Polarization control of such an undulator can be achieved by appropriately choosing the phase of the modes. According to our results, in the fully beam loaded regime, the electron current in the plasma undulator can reach 0.3 kA level, making such an undulator a potential candidate towards a table-Top FEL.« less

  15. Electron dynamics and transverse-kick elimination in a high-field short-period helical microwave undulator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chang, C.; Shumail, M.; Tantawi, S.

    2012-10-15

    Single electron dynamics for a circular polarized standing wave (CPSW) undulator synthesized from a corrugated cavity operating with a very low-loss HE{sub 11} mode are analyzed. The mechanism of the transverse drift of the CPSW undulator and its elimination are researched, and the tapered-field ends are found effectively to suppress the kick. A prototype of the CPSW undulator with the characters of short undulating-period 1.4 cm, high field K {approx} 1, large aperture {approx} 5 cm, and variable polarization is designed and modeled, whose 3-dimensional electromagnetic fields are used to research the suppression of the transverse kick.

  16. Tunable polarization plasma channel undulator for narrow bandwidth photon emission

    DOE PAGES

    Rykovanov, S. G.; Wang, J. W.; Kharin, V. Yu.; ...

    2016-09-09

    The theory of a plasma undulator excited by a short intense laser pulse in a parabolic plasma channel is presented. The undulator fields are generated either by the laser pulse incident off-axis and/or under the angle with respect to the channel axis. Linear plasma theory is used to derive the wakefield structure. It is shown that the electrons injected into the plasma wakefields experience betatron motion and undulator oscillations. Optimal electron beam injection conditions are derived for minimizing the amplitude of the betatron motion, producing narrow-bandwidth undulator radiation. Polarization control is readily achieved by varying the laser pulse injection conditions.

  17. BPMs with Precise Alignment for TTF2

    NASA Astrophysics Data System (ADS)

    Noelle, D.; Priebe, G.; Wendt, M.; Werner, M.

    2004-11-01

    Design and technology of the new, standardized BPM-system for the warm sections of the TESLA Test Facility phase II (TTF2) are presented. Stripline- and button-BPM pickups are read-out with an upgraded version of the AM/PM BPM-electronics of TTF1. The Stripline-BPMs are fixed inside the quadrupole magnets. A stretched wire measurement was used to calibrate the electrical axis of the BPM wrt. to the magnetic axis of the quadrupole.

  18. Micropole undulator

    DOEpatents

    Csonka, P.L.; Tatchyn, R.O.

    1989-01-24

    Micropole undulators for use in the generation of x-rays from moving charged particles and methods for manufacturing such undulators are disclosed. One type of micropole undulator has two jaws containing rows of spaced apart poles arranged so that each pole produces a magnetic field aligned with all other similar fields. An external biasing field extends through the jaws so that an overall undulator field of substantially sinusoidal shape and substantially zero average value extends along the undulator axis. Preferably, the poles are bars formed of a magnetizable, but unmagnetized, material so that, after the jaws are assembled, all of the bars can be magnetized simultaneously in a uniform magnetic field of suitable strength. Another type of micropole undulator incorporates two parallel layers which have been magnetized to provide rows of alternating magnetic fields extending in opposite directions, the layers being positioned between the pole faces of a highly magnetically permeable material with the south poles of one layer opposite the north poles of the other. Poles in the layers are formed by subjecting successive regions of each layer to oppositely directed and suitably varied magnetizing forces. 16 figs.

  19. Micropole undulator

    DOEpatents

    Csonka, Paul L.; Tatchyn, Roman O.

    1989-01-24

    Micropole undulators for use in the generation of x-rays from moving charged particles and methods for manufacturing such undulators are disclosed. One type of micropole undulator has two jaws containing rows of spaced apart poles arranged so that each pole produces a magnetic field aligned with all other similar fields. An external biasing field extends through the jaws so that an overall undulator field of substantially sinusoidal shape and substantially zero average value extends along the undulator axis. Preferably, the poles are bars formed of a magnetizable, but unmagnetized, material so that, after the jaws are assembled, all of the bars can be magnetized simultaneously in a uniform magnetic field of suitable strength. Another type of micropole undulator incorporates two parallel layers which have been magnetized to provide rows of alternating magnetic fields extending in opposite directions, the layers being positioned between the pole faces of a highly magnetically permeable material with the south poles of one layer opposite the north poles of the other. Poles in the layers are formed by subjecting successive regions of each layer to oppositely directed and suitably varied magnetizing forces.

  20. Indentation and overall compression behavior of multilayered thin-film composites. Effect of undulating layer geometry

    DOE PAGES

    Jamison, Ryan D.; Shen, Y. -L.

    2015-03-19

    Two finite element models are used to investigate the behavior of aluminum/silicon carbide thin-film layered composites with imperfect internal geometry when subjected to various loadings. In both models, undulating layers are represented by regular waveforms with various amplitudes, wavelengths, and phase offsets. First, uniaxial compressive loading of the composite is considered. The modulus and stress/strain response of the composite is sensitive to both loading direction and frequency of the undulation. Second, the nanoindentation response of the composite is investigated. The derived hardness and modulus are shown to be sensitive to the presence of undulating layers and the relative size ofmore » the indenter to the undulation. Undulating layers create bands of tensile and compressive stress in the indentation direction that are significantly different from the flat layers. The amount of equivalent plastic strain in the Al layers is increased by the presence of undulating layers. The correlations between the two forms of loading, and the implications to composite property measurement are carefully examined in this study.« less

  1. Feasibility and electromagnetic analysis of a REBCO superconducting undulator

    DOE PAGES

    Kesgin, Ibrahim; Kasa, Matthew; Doose, Charles; ...

    2016-03-17

    Recent advances in second-generation (2G) high temperature superconducting (HTS) coated conductors (CCs) have made them very attractive for new applications such as undulators. In this study, we have, for the first time, experimentally evaluated a design to validate applicability of 2G-HTS tapes for next generation undulator magnetic structures. A two-period undulator magnetic core was fabricated and 2G-HTS CCs were successfully wound onto the undulator core. The performance of the undulator magnetic structure was investigated and the highest engineering current density, J e, in such configuration reported yet was obtained. A new U-slit tape configuration was used to reduce the numbermore » of resistive joints and it was shown that with this new technique affordable levels of resistance values can be achieved for short length undulators. The ferromagnetic core was designed such as to accommodate winding the U-slit tapes. Finally, test results indicated that the winding and the soldering procedures are successful and do not deteriorate the performance of the 2G-HTS tapes.« less

  2. Postural tachycardia syndrome and inappropriate sinus tachycardia: role of autonomic modulation and sinus node automaticity.

    PubMed

    Nwazue, Victor C; Paranjape, Sachin Y; Black, Bonnie K; Biaggioni, Italo; Diedrich, André; Dupont, William D; Robertson, David; Raj, Satish R

    2014-04-10

    Inappropriate sinus tachycardia (IST) and postural tachycardia syndrome (POTS) are 2 disorders characterized by sinus tachycardia. It is debated whether the pathophysiology of IST and POTS results from abnormal autonomic regulation or abnormal sinus node function. We hypothesized that intrinsic heart rate (IHR) after autonomic blockade would be increased in patients with IST but not POTS. We enrolled 48 POTS patients, 8 IST patients, and 17 healthy control (HC) subjects. Intravenous propranolol and atropine were given to block the sympathetic and parasympathetic limbs of the autonomic nervous system in order to determine the IHR. Patients with IST have a higher sympathetic contribution to heart rate when compared with POTS patients (31±13 bpm versus 12±7 bpm, P<0.001) and HC (8±4 bpm; P<0.001) and a trend to less parasympathetic contribution than POTS and HC (IST: 31±11 bpm versus POTS: 46±11 bpm versus HC: 48±11 bpm, ANOVA P=0.108). IHR was not significantly different between IST and either POTS or HC (IST: 111±11 bpm versus POTS: 108±11 bpm versus HC: 106±12 bpm, ANOVA P=0.237). IST patients have more sympathetic tone when compared with either POTS or HC, but IST patients do not have abnormal sinus node automaticity. These data suggest that the treatment of IST and POTS should focus on sympatholysis, reserving sinus node modification for patients with continued debilitating symptoms after beta-blockade and possibly ivabradine. http://clinicaltrials.gov/. Unique identifier: NCT00262470.

  3. Investigation of the polarization state of dual APPLE-II undulators.

    PubMed

    Hand, Matthew; Wang, Hongchang; Dhesi, Sarnjeet S; Sawhney, Kawal

    2016-01-01

    The use of an APPLE II undulator is extremely important for providing a high-brilliance X-ray beam with the capability to switch between various photon beam polarization states. A high-precision soft X-ray polarimeter has been used to systematically investigate the polarization characteristics of the two helical APPLE II undulators installed on beamline I06 at Diamond Light Source. A simple data acquisition and processing procedure has been developed to determine the Stokes polarization parameters for light polarized at arbitrary linear angles emitted from a single undulator, and for circularly polarized light emitted from both undulators in conjunction with a single-period undulator phasing unit. The purity of linear polarization is found to deteriorate as the polarization angle moves away from the horizontal and vertical modes. Importantly, a negative correlation between the degree of circular polarization and the photon flux has been found when the phasing unit is used.

  4. BPM System for Electron Cooling in the Fermilab Recycler Ring

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Joireman, Paul W.; Cai, Jerry; Chase, Brian E.

    2004-11-10

    We report a VXI based system used to acquire and process BPM data for the electron cooling system in the Fermilab Recycler ring. The BPM system supports acquisition of data from 19 BPM locations in five different sections of the electron cooling apparatus. Beam positions for both electrons and anti-protons can be detected simultaneously with a resolution of {+-}50 {mu}m. We calibrate the system independently for each beam type at each BPM location. We describe the system components, signal processing and modes of operation used in support of the electron-cooling project and present experimental results of system performance for themore » developmental electron cooling installation at Fermilab.« less

  5. Performance evaluation of BPM system in SSRF using PCA method

    NASA Astrophysics Data System (ADS)

    Chen, Zhi-Chu; Leng, Yong-Bin; Yan, Ying-Bing; Yuan, Ren-Xian; Lai, Long-Wei

    2014-07-01

    The beam position monitor (BPM) system is of most importance in a light source. The capability of the BPM depends on the resolution of the system. The traditional standard deviation on the raw data method merely gives the upper limit of the resolution. Principal component analysis (PCA) had been introduced in the accelerator physics and it could be used to get rid of the actual signals. Beam related information was extracted before the evaluation of the BPM performance. A series of studies had been made in the Shanghai Synchrotron Radiation Facility (SSRF) and PCA was proved to be an effective and robust method in the performance evaluations of our BPM system.

  6. Screening for coronary artery disease in respiratory patients: comparison of single- and dual-source CT in patients with a heart rate above 70 bpm.

    PubMed

    Pansini, Vittorio; Remy-Jardin, Martine; Tacelli, Nunzia; Faivre, Jean-Baptiste; Flohr, Thomas; Deken, Valérie; Duhamel, Alain; Remy, Jacques

    2008-10-01

    To evaluate the assessibility of coronary arteries in respiratory patients with high heart rates. This study was based on the comparative analysis of two paired populations of 54 patients with a heart rate >70 bpm evaluated with dual-source (group 1) and single-source (group 2) CT. The mean heart rate was 89.1 bpm in group 1 and 86.7 bpm in group 2 (P=0.26). The mean number of assessable segments per patient was significantly higher in group 1 compared to group 2 (P

  7. A multi-channel opto-electronic sensor to accurately monitor heart rate against motion artefact during exercise.

    PubMed

    Alzahrani, Abdullah; Hu, Sijung; Azorin-Peris, Vicente; Barrett, Laura; Esliger, Dale; Hayes, Matthew; Akbare, Shafique; Achart, Jérôme; Kuoch, Sylvain

    2015-10-12

    This study presents the use of a multi-channel opto-electronic sensor (OEPS) to effectively monitor critical physiological parameters whilst preventing motion artefact as increasingly demanded by personal healthcare. The aim of this work was to study how to capture the heart rate (HR) efficiently through a well-constructed OEPS and a 3-axis accelerometer with wireless communication. A protocol was designed to incorporate sitting, standing, walking, running and cycling. The datasets collected from these activities were processed to elaborate sport physiological effects. t-test, Bland-Altman Agreement (BAA), and correlation to evaluate the performance of the OEPS were used against Polar and Mio-Alpha HR monitors. No differences in the HR were found between OEPS, and either Polar or Mio-Alpha (both p > 0.05); a strong correlation was found between Polar and OEPS (r: 0.96, p < 0.001); the bias of BAA 0.85 bpm, the standard deviation (SD) 9.20 bpm, and the limits of agreement (LOA) from -17.18 bpm to +18.88 bpm. For the Mio-Alpha and OEPS, a strong correlation was found (r: 0.96, p < 0.001); the bias of BAA 1.63 bpm, SD 8.62 bpm, LOA from -15.27 bpm to +18.58 bpm. These results demonstrate the OEPS to be capable of carrying out real time and remote monitoring of heart rate.

  8. Influence of the motion correction algorithm on the quality and interpretability of images of single-source 64-detector coronary CT angiography among patients grouped by heart rate.

    PubMed

    Machida, Haruhiko; Lin, Xiao-Zhu; Fukui, Rika; Shen, Yun; Suzuki, Shigeru; Tanaka, Isao; Ishikawa, Takuya; Tate, Etsuko; Ueno, Eiko

    2015-02-01

    We retrospectively investigated the effect of the motion correction algorithm (MCA) on image quality and interpretability by heart rate (HR) in coronary CT angiography (CCTA). For 105 patients (6 HR groups) undergoing CCTA, 2 readers independently graded the image quality of the 4 major coronary arteries reconstructed with and without MCA at diastole with HR ≤64 bpm and at systole and diastole ≥65 bpm using a 5-point scale. For each HR group and cardiac phase, we compared per-vessel and per-segment image quality using Wilcoxon signed rank test and percentages of interpretable image quality (scores 3-5) among without MCA at diastole with HR ≤64 bpm, as a reference, with MCA at diastole ≤69 bpm and at systole 70-79 bpm using the chi-square test. The motion correction algorithm reconstruction provided similar or better image quality and interpretability in all groups, with 96-100 % per-vessel (P = 0.008 for the right coronary artery; otherwise, P > 0.05) and 99 % per-segment interpretable image quality (P = 0.0002) at diastole with HR ≤69 bpm and at systole 70-79 bpm compared to the reference (88-100 and 97 %, respectively). MCA reconstruction preserved image quality and interpretability of CCTA with HR ≤79 bpm.

  9. A fast analytical undulator model for realistic high-energy FEL simulations

    NASA Astrophysics Data System (ADS)

    Tatchyn, R.; Cremer, T.

    1997-02-01

    A number of leading FEL simulation codes used for modeling gain in the ultralong undulators required for SASE saturation in the <100 Å range employ simplified analytical models both for field and error representations. Although it is recognized that both the practical and theoretical validity of such codes could be enhanced by incorporating realistic undulator field calculations, the computational cost of doing this can be prohibitive, especially for point-to-point integration of the equations of motion through each undulator period. In this paper we describe a simple analytical model suitable for modeling realistic permanent magnet (PM), hybrid/PM, and non-PM undulator structures, and discuss selected techniques for minimizing computation time.

  10. Proposal of a Bulk HTSC Staggered Array Undulator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kii, Toshiteru; Kinjo, Ryota; Bakr, Mahmoud A.

    We proposed a new type of undulator based on bulk high-T{sub c} superconductors (HTSC) which consists of a single solenoid and a stacked array of bulk HTSC. The main advantage of this configuration is that a mechanical structure is not required to produce and control the undulator field. In order to perform a proof of principle experiment, we have developed a prototype of bulk HTSC staggered array undulator using 11 pairs of DyBaCuO bulk superconductors and a normal conducting solenoid. Experimental results obtained by using the prototype undulator and numerical results obtained by a loop current model based on themore » Bean mode for a type-II superconductor were compared.« less

  11. Reduction of resting heart rate with antianginal drugs: review and meta-analysis.

    PubMed

    Cucherat, Michel; Borer, Jeffrey S

    2012-07-01

    The benefit of heart rate (HR) reduction in patients with stable coronary artery disease is well demonstrated for symptom prevention and relief, and benefits on outcomes are being actively investigated. We aimed to quantify the reduction in resting HR induced by 5 antianginal drugs frequently used for symptom prevention (diltiazem, verapamil, atenolol, metoprolol, and ivabradine) in stable angina pectoris. We identified studies published between 1966 and 2007 in PubMed, Embase, and the Cochrane database and reviewed the bibliographies to locate additional studies. Eligible studies were double-blind, randomized, placebo-controlled trials in patients with stable angina. Trials were combined using weighted mean difference and fixed-effect model meta-analysis. The main outcome measure was resting HR at the study end. For diltiazem, resting HR reduction versus placebo ranged from -0.08 beats per minute (bpm) [95% confidence interval (CI) -1.5 to +1.4] for 120 mg/d to -8.0 bpm (95% CI, -11.1 to -5.0) with 360 mg/d. For sustained-release diltiazem, there was a reduction in resting HR of -4.5 bpm (95% CI, -6.4 to -2.5), with no dose-response relationship (heterogeneity P = 0.62). Resting HR reductions for the other agents were -3.2 bpm (95% CI, -5.1 to -1.3) for verapamil (with no dose-response relationship, heterogeneity P = 0.87); -19.0 bpm (95% CI, -20.4 to -17.6) for atenolol; -13.2 bpm (95% CI, -14.7 to -11.7) for metoprolol (with greater reductions for 150 mg/d and long-acting 190 mg/d); and between -9.3 bpm (95% CI, -13.8 to -4.8) and -19.6 bpm (95% CI, -23.8 to -15.4) for ivabradine. Ivabradine, atenolol, and metoprolol give similar reductions in resting HR (-10 to -20 bpm), whereas verapamil and diltiazem produce only marginal reductions (<10 bpm).

  12. [Heart rate control in chronic heart failure patients received cardiovascular implantable electronic device therapy: effects of optimized medication].

    PubMed

    Gao, Y; Liang, Y C; Yu, H B; Yan, X L; Xu, B G; Liu, R; Wang, N; Xu, G Q; Wang, Z L

    2018-03-24

    Objective: To investigate the heart rate control situation of chronic heart failure (CHF) patients who received cardiovascular implantable electronic device (CIED) therapy, and to assess the heart rate control efficacy by optimized medication adjustment. Methods: We performed a perspective study in heart failure with reduced left ventricular ejection fraction (HFrEF) patients who received CIED according to guideline recommendations, patients were enrolled from January 2012 to January 2017. Resting heart rate (RHR) recorded by electrocardiogram after 10 minutes' rest and medication usage within 1 month were recorded at baseline. RHR less than 70 beats per minute (bpm) was regarded as well controlled. β-receptor blockers and (or) ivabradine would be added in patients whose RHR were over 70 bpm. RHR after optimized medication adjustment was recorded during follow-up period. Results: One hundred and fifty patients were included in this study with average RHR (80.6±11.9) bpm. RHR was<70 bpm in 27.3% (41/150) patients at baseline and β-receptor blockers was underused in 80.7% patients (88/109) whose RHR was>70 bpm. The overall RHR decreased to (73.1±10.4) bpm and percent of patients with RHR<70 bpm increased to 70.0% (105/150) after up-titration of β-receptor blockers compared to baseline (χ 2 =52.958, P< 0.001). Ivabradine was added in the rest 45 patients and RHR was<70 bpm in 43 out of 45 patients after ivabradine use. The overall RHR decreased to (67.1±2.7) bpm and percent of RHR<70 bpm significantly increased to 98.7% (148/150) (χ 2 =44.504, P< 0.001 vs. up-titration of β-receptor blockers only). Conclusion: RHR in CHF patients who received CIED therapy is not ideally controlled in this patient cohort, individual up-titration ofβ-receptor blockers and ivabradine use may help to optimize RHR in these patients.

  13. Association between resting heart rate, metabolic syndrome and cardiorespiratory fitness in Korean male adults.

    PubMed

    Kang, Seol-Jung; Ha, Gi-Chul; Ko, Kwang-Jun

    2017-06-01

    The present study aimed to investigate the association between metabolic syndrome and cardiorespiratory fitness according to resting heart rate of Korean male adults. A total of 11,876 male adults aged 20-65 years who underwent health examinations from 2010 to 2015 at a National Fitness Centre in South Korea were included. Subjects' resting heart rate, cardiorespiratory fitness (VO 2 max), and metabolic syndrome parameters were collected. The subjects were divided into 5 categories (<60 bpm, 60-69 bpm, 70-79 bpm, 80-89 bpm, and ≥90 bpm) of resting heart rate for further analysis. We found that elevated resting heart rate was positively associated with body mass index, systolic blood pressure, diastolic blood pressure, triglycerides, and fasting blood glucose levels ( p  < 0.001, respectively); in contrast, elevated resting heart rate was inversely associated with VO 2 max ( p  < 0.001). When resting heart rate of subjects was categorized into quintiles and analysed, the results showed that the relative risk of metabolic syndrome was 1.53-fold higher (95% CI, 1.34 to 1.82) in the range of 60-69 beats per minute (bpm), 2.08-fold higher (95% CI, 1.77 to 2.45) in the range of 70-79 bpm, 2.28-fold higher (95% CI, 1.73 to 3.00) in the range of 80-89 bpm, and 2.61-fold higher (95% CI, 1.62 to 4.20) in the range of ≥90 bpm, compared to those <60 bpm; this indicated that as resting heart rate increased, the relative risk of metabolic syndrome also increased. Resting heart rate of male adults was found to be associated with cardiorespiratory fitness; the risk factors for metabolic syndrome and relative risk of metabolic syndrome increased as resting heart rate increased.

  14. [Time-dependent heart rate variability in the head-up tilt test in children with postural orthostatic tachycardia syndrome].

    PubMed

    Ran, Jing; Wang, Cheng; Zou, Run-Mei; Wu, Li-Jia; Lin, Ping; Li, Fang; Xu, Yi

    2015-10-01

    To study the time-dependent heart rate (HR) variability in the head-up tilt test (HUTT) in children with postural orthostatic tachycardia syndrome (POTS) and to explore the HR diagnostic criteria for POTS in children. A retrospective analysis was performed on the clinical data of 105 children diagnosed with POTS with HR≥120 beats per minute (bpm) within the first 10 minutes of HUTT between January 2007 and December 2014. Their HR variability within the first 10 minutes of HUTT was analyzed. The HR of children with POTS increased gradually from the supine position to a 60° head-up tilt position, and the increase in HR was 24±12 bpm at the beginning of HUTT, 30±14 bpm at 3 minutes of HUTT, 32±13 bpm at 5 minutes of HUTT, and 38±12 bpm at 10 minutes of HUTT. The average maximal HR increase within the first 10 minutes of HUTT was 43±10 bpm. In children with POTS, the HR variability gradually increases with time, and therefore, it is suggested that HR increase ≥40 bpm is more suitable for diagnosis of POTS in children.

  15. Modulation of Ca(v)3.1 T-type Ca2+ channels by the ran binding protein RanBPM.

    PubMed

    Kim, Taehyun; Kim, Sunoh; Yun, Hyung-Mun; Chung, Kwang Chul; Han, Ye Sun; Shin, Hee-Sup; Rhim, Hyewhon

    2009-01-02

    In order to study the currently unknown cellular signaling pathways of Ca(v)3.1 T-type Ca(2+) channels (Ca(v)3.1 channels), we performed a yeast two-hybrid screening using intracellular domains of Ca(v)3.1 alpha1 subunit as bait. After screening the human brain cDNA library, several proteins, including RanBPM, were identified as interacting with Ca(v)3.1 channels. RanBPM was found to bind to the cytoplasmic intracellular loop between transmembrane domains I and II of Ca(v)3.1 channels. Using whole-cell patch-clamp techniques, we found that Ca(v)3.1 currents were increased by the expression of RanBPM in HEK293/Ca(v)3.1 cells. We next examined whether RanBPM affected the biophysical properties and plasma membrane expression of Ca(v)3.1 channels. Furthermore, we showed that the PKC activator inhibited Ca(v)3.1 currents, an effect that was abolished by the expression of RanBPM. These results suggest that RanBPM could be a key regulator of Ca(v)3.1 channel-mediated signaling pathways.

  16. First observation of undulator radiation from APPLE-1

    NASA Astrophysics Data System (ADS)

    Sasaki, Shigemi; Shimada, Taihei; Yanagida, Ken-ichi; Kobayashi, Hideki; Miyahara, Yoshikazu

    1994-08-01

    Various polarized radiation was observed in the visible region generated by the new type undulator APPLE-1 (Advanced Planar Polarized Light Emitted - 1). The undulator was installed in the low energy electron storage ring JSR and we have succeeded in observing linearly polarized radiation in both planes and circularly polarized radiation with the aid of a Wollaston prism. During the process of shifting the arrays and changing the undulator gap, no noticeable change of radiation axis was observed.

  17. Law Enforcement Head-Borne Personal Protective Equipment Hearing Attenuation

    DTIC Science & Technology

    2009-04-01

    thus allowing for a binaural recording to be captured. The BOB was placed on a manual turntable to allow the BOB to be rotated along the azimuth...listed in the Appendix. Each movement should be conducted 8 times at a rate of 50 beats per minute (BPM) and 80 BPM; this will be defined as slow...APPENDIX FABRIC NOISE TEST MOVEMENTS AND SPEEDS The below movements must be performed at a rate of 50 beats per minute (BPM) and 80 BPM: Movement

  18. Comparing in vitro and in vivo virulence phenotypes of Burkholderia pseudomallei type G strains.

    PubMed

    Lewis, Eric R G; Kilgore, Paul B; Mott, Tiffany M; Pradenas, Gonzalo A; Torres, Alfredo G

    2017-01-01

    Burkholderia pseudomallei (Bpm) is a saprophytic rod-shaped gram-negative bacterium and the causative agent of melioidosis. This disease has previously been described as endemic in areas such as northern Australia and Southeast Asia, but, more recently, a better understanding of the epidemiology of melioidosis indicated that the disease is distributed worldwide, including regions of the Americas and Africa. A 16S-23S rDNA internal transcribed spacer (ITS) typing system has been developed for Bpm and has revealed that ITS types C, E, and hybrid CE are mainly associated with Australia and Southeast Asia while type G strains are more associated with cases of melioidosis in the Western Hemisphere. The purpose of the current study was to determine the in vitro and in vivo virulence profiles of the understudied Bpm type G strains Ca2009, Ca2013a, Mx2013, and 724644 and compared such phenotypes to the commonly studied Bpm type C strain K96243. We evaluated virulence by measuring invasion/uptake and survival of these Bpm strains in murine respiratory epithelial LA-4 cells and alveolar macrophage MH-S cells using different multiplicity of infections (MOIs of 1 and 10). We also calculated the lethal dose 50 values (LD50) in BALB/c mice that were inoculated intranasally with either Ca2009, Ca2013a, or Mx2013. Overall, the virulence and lethality phenotypes of Bpm type G strains were similar to the Bpm type C strain K96243. Additional comparative analyses between the Bpm ITS types may lead to a better understanding of the contribution of the ITS type to the epidemiology and ecology of Bpm strains.

  19. Performance of turbo high-pitch dual-source CT for coronary CT angiography: first ex vivo and patient experience.

    PubMed

    Morsbach, Fabian; Gordic, Sonja; Desbiolles, Lotus; Husarik, Daniela; Frauenfelder, Thomas; Schmidt, Bernhard; Allmendinger, Thomas; Wildermuth, Simon; Alkadhi, Hatem; Leschka, Sebastian

    2014-08-01

    To evaluate image quality, maximal heart rate allowing for diagnostic imaging, and radiation dose of turbo high-pitch dual-source coronary computed tomographic angiography (CCTA). First, a cardiac motion phantom simulating heart rates (HRs) from 60-90 bpm in 5-bpm steps was examined on a third-generation dual-source 192-slice CT (prospective ECG-triggering, pitch 3.2; rotation time, 250 ms). Subjective image quality regarding the presence of motion artefacts was interpreted by two readers on a four-point scale (1, excellent; 4, non-diagnostic). Objective image quality was assessed by calculating distortion vectors. Thereafter, 20 consecutive patients (median, 50 years) undergoing clinically indicated CCTA were included. In the phantom study, image quality was rated diagnostic up to the HR75 bpm, with object distortion being 1 mm or less. Distortion increased above 1 mm at HR of 80-90 bpm. Patients had a mean HR of 66 bpm (47-78 bpm). Coronary segments were of diagnostic image quality for all patients with HR up to 73 bpm. Average effective radiation dose in patients was 0.6 ± 0.3 mSv. Our combined phantom and patient study indicates that CCTA with turbo high-pitch third-generation dual-source 192-slice CT can be performed at HR up to 75 bpm while maintaining diagnostic image quality, being associated with an average radiation dose of 0.6 mSv. • CCTA is feasible with the turbo high-pitch mode. • Turbo high-pitch CCTA provides diagnostic image quality up to 73 bpm. • The radiation dose of high-pitch CCTA is 0.6 mSv on average.

  20. Comparing in vitro and in vivo virulence phenotypes of Burkholderia pseudomallei type G strains

    PubMed Central

    Mott, Tiffany M.; Pradenas, Gonzalo A.

    2017-01-01

    Burkholderia pseudomallei (Bpm) is a saprophytic rod-shaped gram-negative bacterium and the causative agent of melioidosis. This disease has previously been described as endemic in areas such as northern Australia and Southeast Asia, but, more recently, a better understanding of the epidemiology of melioidosis indicated that the disease is distributed worldwide, including regions of the Americas and Africa. A 16S-23S rDNA internal transcribed spacer (ITS) typing system has been developed for Bpm and has revealed that ITS types C, E, and hybrid CE are mainly associated with Australia and Southeast Asia while type G strains are more associated with cases of melioidosis in the Western Hemisphere. The purpose of the current study was to determine the in vitro and in vivo virulence profiles of the understudied Bpm type G strains Ca2009, Ca2013a, Mx2013, and 724644 and compared such phenotypes to the commonly studied Bpm type C strain K96243. We evaluated virulence by measuring invasion/uptake and survival of these Bpm strains in murine respiratory epithelial LA-4 cells and alveolar macrophage MH-S cells using different multiplicity of infections (MOIs of 1 and 10). We also calculated the lethal dose 50 values (LD50) in BALB/c mice that were inoculated intranasally with either Ca2009, Ca2013a, or Mx2013. Overall, the virulence and lethality phenotypes of Bpm type G strains were similar to the Bpm type C strain K96243. Additional comparative analyses between the Bpm ITS types may lead to a better understanding of the contribution of the ITS type to the epidemiology and ecology of Bpm strains. PMID:28414823

  1. Effects of renal sympathetic denervation on heart rate and atrioventricular conduction in patients with resistant hypertension.

    PubMed

    Ukena, Christian; Mahfoud, Felix; Spies, Aline; Kindermann, Ingrid; Linz, Dominik; Cremers, Bodo; Laufs, Ulrich; Neuberger, Hans-Ruprecht; Böhm, Michael

    2013-09-10

    Renal sympathetic denervation (RDN) reduces sympathetic activity and blood pressure (BP) in patients with resistant hypertension. The present study aimed to investigate the effects of RDN on HR and other electrocardiographic parameters. 136 patients aged 62.2 ± 0.8 years (58% male, BP 177 ± 2/93 ± 1 mmHg) with resistant hypertension underwent RDN. BP and a 12-lead electrocardiogram (ECG) were recorded before, 3 months (n=127), and 6 months (n=88) after RDN. After 3 months (3M) and 6 months (6M), systolic BP was reduced by 25.5 ± 2.4 mmHg (p<0.0001) and 28.1 ± 3 mmHg (p<0.0001). HR at baseline was 66.1 ± 1 beats per minute (bpm) and was reduced by 2.6 ± 0.8 bpm after 3 months (p=0.001) and 2.1 ± 1.1 bpm after 6 months (p=0.046). Patients with HR at baseline between 60-71 bpm and ≥ 71 bpm had a reduction of 2.9 ± 7.6 bpm (p=0.008) and 9.0 ± 8.6 bpm (p<0.0001), respectively, whereas in patients with baseline HR<60 bpm HR slightly increased after 3 months (2.7 ± 8.4 bpm; p=0.035). Neither baseline HR nor change of HR correlated with the reduction of systolic BP. The PR interval was prolonged by 11.3 ± 2.5 ms (p<0.0001) and 10.3 ± 2.5 ms (p<0.0001) at 3 and 6 months after RDN, respectively. Renal sympathetic denervation reduced heart rate and the PR interval as indicators of cardiac autonomic activity. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  2. Respiratory rates measured by a standardised clinical approach, ward staff, and a wireless device.

    PubMed

    Granholm, A; Pedersen, N E; Lippert, A; Petersen, L F; Rasmussen, L S

    2016-11-01

    Respiratory rate is among the first vital signs to change in deteriorating patients. The aim was to investigate the agreement between respiratory rate measurements by three different methods. This prospective observational study included acutely admitted adult patients in a medical ward. Respiratory rate was measured by three methods: a standardised approach over 60 s while patients lay still and refrained from talking, by ward staff and by a wireless electronic patch (SensiumVitals). The Bland-Altman method was used to compare measurements and three breaths per minute (BPM) was considered a clinically relevant difference. We included 50 patients. The mean difference between the standardised approach and the electronic measurement was 0.3 (95% CI: -1.4 to 2.0) BPM; 95% limits of agreement were -11.5 (95% CI: -14.5 to -8.6) and 12.1 (95% CI: 9.2 to 15.1) BPM. Removal of three outliers with huge differences lead to a mean difference of -0.1 (95% CI: -0.7 to 0.5) BPM and 95% limits of agreement of -4.2 (95% CI: -5.3 to -3.2) BPM and 4.0 (95% CI: 2.9 to 5.0) BPM. The mean difference between staff and electronic measurements was 1.7 (95% CI: -0.5 to 3.9) BPM; 95% limits of agreement were -13.3 (95% CI: -17.2 to -9.5) BPM and 16.8 (95% CI: 13.0 to 20.6) BPM. A concerning lack of agreement was found between a wireless monitoring system and a standardised clinical approach. Ward staff's measurements also seemed to be inaccurate. © 2016 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  3. Development and operation of a Pr 2 Fe 14 B based cryogenic permanent magnet undulator for a high spatial resolution x-ray beam line

    DOE PAGES

    Benabderrahmane, C.; Valleau, M.; Ghaith, A.; ...

    2017-03-02

    Short period, high field undulators are used to produce hard x-rays on synchrotron radiation based storage ring facilities of intermediate energy and enable short wavelength free electron laser. Cryogenic permanent magnet undulators take benefit from improved magnetic properties of RE 2Fe 14B (Rare Earth based magnets) at low temperatures for achieving short period, high magnetic field and high coercivity. Using Pr 2Fe 14B instead of Nd 2Fe 14B, which is generally employed for undulators, avoids the limitation caused by the spin reorientation transition phenomenon, and simplifies the cooling system by allowing the working temperature of the undulator to be directlymore » at the liquid nitrogen one (77 K). We describe here the development of a full scale (2 m), 18 mm period Pr 2Fe 14B cryogenic permanent magnet undulator (U18). The design, construction and optimization, as well as magnetic measurements and shimming at low temperature are presented. In conclusion, the commissioning and operation of the undulator with the electron beam and spectrum measurement using the Nanoscopmium beamline at SOLEIL are also reported.« less

  4. Proposed Laser-driven, Dielectric Microstructure Few-cm Long Undulator for Attosecond Coherent X-rays

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Plettner, T; Byer, R.L.; /Stanford U., Ginzton Lab.

    This article presents the concept of an all-dielectric laser-driven undulator for the generation of coherent X-rays. The proposed laser-driven undulator is expected to produce internal deflection forces equivalent to a several-Tesla magnetic field acting on a speed-of-light particle. The key idea for this laser-driven undulator is its ability to provide phase synchronicity between the deflection force and the electron beam for a distance that is much greater than the laser wavelength. The potential advantage of this undulator is illustrated with a possible design example that assumes a small laser accelerator which delivers a 2 GeV, 1 pC, 1 kHz electronmore » bunch train to a 10 cm long, 1/2 mm period laser-driven undulator. Such an undulator could produce coherent X-ray pulses with {approx}10{sup 9} photons of 64 keV energy. The numerical modeling for the expected X-ray pulse shape was performed with GENESIS, which predicts X-ray pulse durations in the few-attosecond range. Possible applications for nonlinear electromagnetic effects from these X-ray pulses are briefly discussed.« less

  5. Development and operation of a Pr 2 Fe 14 B based cryogenic permanent magnet undulator for a high spatial resolution x-ray beam line

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Benabderrahmane, C.; Valleau, M.; Ghaith, A.

    Short period, high field undulators are used to produce hard x-rays on synchrotron radiation based storage ring facilities of intermediate energy and enable short wavelength free electron laser. Cryogenic permanent magnet undulators take benefit from improved magnetic properties of RE 2Fe 14B (Rare Earth based magnets) at low temperatures for achieving short period, high magnetic field and high coercivity. Using Pr 2Fe 14B instead of Nd 2Fe 14B, which is generally employed for undulators, avoids the limitation caused by the spin reorientation transition phenomenon, and simplifies the cooling system by allowing the working temperature of the undulator to be directlymore » at the liquid nitrogen one (77 K). We describe here the development of a full scale (2 m), 18 mm period Pr 2Fe 14B cryogenic permanent magnet undulator (U18). The design, construction and optimization, as well as magnetic measurements and shimming at low temperature are presented. In conclusion, the commissioning and operation of the undulator with the electron beam and spectrum measurement using the Nanoscopmium beamline at SOLEIL are also reported.« less

  6. Polarization characteristics of radiation in both 'light' and conventional undulators

    NASA Astrophysics Data System (ADS)

    Potylitsyn, A. P.; Kolchuzhkin, A. M.; Strokov, S. A.

    2017-07-01

    As a rule, an intensity spectrum of undulator radiation (UR) is calculated by using the classical approach, even for electron energy higher than 10 GeV. Such a spectrum is determined by an electron trajectory in an undulator while neglecting radiation loss. Using Planck's law, the UR photon spectrum can be calculated from the obtained intensity spectrum, for both linear and nonlinear regimes. The electron radiation process in a field of strong electromagnetic waves is considered within the quantum electrodynamics framework, using the Compton scattering process or radiation in a 'light' undulator. A comparison was made of the results from using these two approaches, for UR spectra generated by 250-GeV electrons in an undulator with a 11.5-mm period; this comparison shows that they coincide with high accuracy. The characteristics of the collimated UR beam (i.e. spectrum and circular polarization) were simulated while taking into account the discrete process of photon emission along an electron trajectory in both undulator types. Both spectral photon distributions and polarization dependence on photon energy are 'smoothed', in comparison to that expected for a long undulator-the latter of which considers the ILC positron source (ILC Technical Design Report).

  7. Development and operation of a Pr2 Fe14 B based cryogenic permanent magnet undulator for a high spatial resolution x-ray beam line

    NASA Astrophysics Data System (ADS)

    Benabderrahmane, C.; Valléau, M.; Ghaith, A.; Berteaud, P.; Chapuis, L.; Marteau, F.; Briquez, F.; Marcouillé, O.; Marlats, J.-L.; Tavakoli, K.; Mary, A.; Zerbib, D.; Lestrade, A.; Louvet, M.; Brunelle, P.; Medjoubi, K.; Herbeaux, C.; Béchu, N.; Rommeluere, P.; Somogyi, A.; Chubar, O.; Kitegi, C.; Couprie, M.-E.

    2017-03-01

    Short period, high field undulators are used to produce hard x-rays on synchrotron radiation based storage ring facilities of intermediate energy and enable short wavelength free electron laser. Cryogenic permanent magnet undulators take benefit from improved magnetic properties of RE2 Fe14B (Rare Earth based magnets) at low temperatures for achieving short period, high magnetic field and high coercivity. Using Pr2 Fe14B instead of Nd2 Fe14B , which is generally employed for undulators, avoids the limitation caused by the spin reorientation transition phenomenon, and simplifies the cooling system by allowing the working temperature of the undulator to be directly at the liquid nitrogen one (77 K). We describe here the development of a full scale (2 m), 18 mm period Pr2 Fe14B cryogenic permanent magnet undulator (U18). The design, construction and optimization, as well as magnetic measurements and shimming at low temperature are presented. The commissioning and operation of the undulator with the electron beam and spectrum measurement using the Nanoscopmium beamline at SOLEIL are also reported.

  8. An Information System Development Method Connecting Business Process Modeling and its Experimental Evaluation

    NASA Astrophysics Data System (ADS)

    Okawa, Tsutomu; Kaminishi, Tsukasa; Kojima, Yoshiyuki; Hirabayashi, Syuichi; Koizumi, Hisao

    Business process modeling (BPM) is gaining attention as a measure of analysis and improvement of the business process. BPM analyses the current business process as an AS-IS model and solves problems to improve the current business and moreover it aims to create a business process, which produces values, as a TO-BE model. However, researches of techniques that connect the business process improvement acquired by BPM to the implementation of the information system seamlessly are rarely reported. If the business model obtained by BPM is converted into UML, and the implementation can be carried out by the technique of UML, we can expect the improvement in efficiency of information system implementation. In this paper, we describe a method of the system development, which converts the process model obtained by BPM into UML and the method is evaluated by modeling a prototype of a parts procurement system. In the evaluation, comparison with the case where the system is implemented by the conventional UML technique without going via BPM is performed.

  9. Tapered undulator for SASE FELs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fawley, William M.; Huang, Zhirong; Kim, Kwang-Je

    We discuss the use of tapered undulators to enhance the performance of free-electron lasers (FELs) based upon self-amplified spontaneous emission (SASE), where the radiation tends to have a relatively broad bandwidth, limited temporal phase coherence, and large amplitude fluctuations. Using the polychromatic FEL simulation code GINGER, we numerically demonstrate the effectiveness of a tapered undulator for parameters corresponding to the existing Argonne low-energy undulator test line (LEUTL) FEL. We also study possible tapering options for proposed x-ray FELs such as the Linac Coherent Light Source (LCLS).

  10. Towards a better understanding of honeycomb alternating magnetic networks.

    PubMed

    Marino, Nadia; Armentano, Donatella; De Munno, Giovanni; Lloret, Francesc; Cano, Joan; Julve, Miguel

    2015-06-28

    Two new two-dimensional homometallic compounds {[M2(bpm)(ox)2]n·5nH2O} with M = Co(II) (1) and Zn(II) (2) and the mononuclear nickel(II) complex [Ni(bpm)2(ox)]·2H2O (3) [bpm = 2,2'-bipyrimidine and ox = oxalate] have been prepared and structurally characterized. 1 and 2 are isostructural compounds whose structures are made up of oxalate-bridged M(II) cations cross-linked by bis-bidentate bpm molecules to afford a honeycomb layered network extending in the crystallographic ab plane. The layers are eclipsed along the crystallographic c axis and show graphitic-like interactions between the bpm rings. The three-dimensional supramolecular network deriving from such interactions is characterized by hexagonal-shaped channels extending in the same direction. Each M(II) ion in 1 and 2 is tris-chelated with four oxygen atoms from two oxalate groups and two bpm-nitrogen atoms building a distorted octahedral surrounding. The reduced values of the angles subtended by the bis-chelating bpm [77.69(8) (1) and 76.59(8)° (2)] and oxalate [79.69(6) (1) and 80.01(5)° (2)] are the main factors accounting for this distortion. The values of the metal-metal separation through bridging bpm are 5.6956(7) (1) and 5.7572(9) Å (2), whereas those across the bis-bidentate oxalate are 5.4306(4) (1) and 5.4058(5) Å (2). 3 is a neutral mononuclear nickel(II) complex where each metal ion is six-coordinate with four nitrogen atoms from two bpm ligands in a cis arrangement and two oxalate-oxygen atoms building a somewhat distorted octahedral surrounding. The values of the angles subtended at the nickel(II) ion by bpm and oxalate are 78.14(4) and 80.95(5)°, respectively. The magnetic properties of 1 have been investigated in the temperature range 1.9-295 K. They are typical of an overall antiferromagnetic coupling with a maximum of the magnetic susceptibility at 22.0 K. The analysis of the susceptibility data of 1 through an effective spin Hamiltonian allowed a satisfactory simulation in the temperature range 10-295 K with the best-fit parameters λ = -110 cm(-1), α = 1.1, |Δ| = 400 cm(-1), J(ox) = -11.1 cm(-1) and J(bpm) = -5.0 cm(-1). The values of the antiferromagnetic coupling through bpm and ox in 1 have also been supported by electronic structure calculations based on Density Functional Theory (DFT) and they compare well with those reported in the literature for bpm-bridged dicobalt(II) complexes and oxalate-bridged cobalt(II) chains.

  11. Measured maximal heart rates compared to commonly used age-based prediction equations in the Heritage Family Study.

    PubMed

    Sarzynski, M A; Rankinen, T; Earnest, C P; Leon, A S; Rao, D C; Skinner, J S; Bouchard, C

    2013-01-01

    The purpose of this study was to examine how well two commonly used age-based prediction equations for maximal heart rate (HRmax ) estimate the actual HRmax measured in Black and White adults from the HERITAGE Family Study. A total of 762 sedentary subjects (39% Black, 57% Females) from HERITAGE were included. HRmax was measured during maximal exercise tests using cycle ergometers. Age-based HRmax was predicted using the Fox (220-age) and Tanaka (208 - 0.7 × age) formulas. The standard error of estimate (SEE) of predicted HRmax was 12.4 and 11.4 bpm for the Fox and Tanaka formulas, respectively, indicating a wide-spread of measured-HRmax values are compared to their age-predicted values. The SEE (shown as Fox/Tanaka) was higher in Blacks (14.4/13.1 bpm) and Males (12.6/11.7 bpm) compared to Whites (11.0/10.2 bpm) and Females (12.3/11.2 bpm) for both formulas. The SEE was higher in subjects above the BMI median (12.8/11.9 bpm) and below the fitness median (13.4/12.4 bpm) when compared to those below the BMI median (12.2/11.0 bpm) and above the fitness median (11.4/10.3) for both formulas. Our findings show that based on the SEE, the prevailing age-based estimated HRmax equations do not precisely predict an individual's measured-HRmax . Copyright © 2013 Wiley Periodicals, Inc.

  12. Transverse gradient in Apple-type undulators

    PubMed Central

    Calvi, M.; Camenzuli, C.; Prat, E.; Schmidt, Th.

    2017-01-01

    Apple-type undulators are globally recognized as the most flexible devices for the production of variable polarized light in the soft X-ray regime, both at synchrotron and free-electron laser facilities. Recently, the implementation of transverse gradient undulators has been proposed to enhance the performance of new generation light sources. In this paper it is demonstrated that Apple undulators do not only generate linear and elliptical polarized light but also variable transverse gradient under certain conditions. A general theoretical framework is introduced to evaluate the K-value and its transverse gradient for an Apple undulator, and formulas for all regular operational modes and different Apple types (including the most recent Delta type and Apple X) are calculated and critically discussed. PMID:28452751

  13. Aerodynamics and Aerothermodynamics of undulated re-entry vehicles

    NASA Astrophysics Data System (ADS)

    Kaushikh, K.; Arunvinthan, S.; Pillai, S. Nadaraja

    2018-01-01

    Aerodynamic and aerothermodynamic analysis is a fundamental basis for the design of a hypersonic vehicle. In this work, aerodynamic and aerothermodynamic analyses of a blunt body vehicle with undulations on its after-body are studied with the help of numerical simulations. A crew exploration vehicle (CEV) is taken for initial analysis and undulations with varying amplitude and wavelength are introduced on CEV's after-body. Numerical simulations were carried out for CEV and for CEV with undulations at Mach 3.0 and 7.0 for angles of attack ranging from -20° to +20° with increments of +5°. The results show that introduction of undulations did not have a significant impact on mono stability and lift-drag characteristics of the vehicle. It was also observed that introduction of undulations improved the aerothermodynamic characteristics of CEV. A reduction of about 36% in maximum heat flux at Mach 3.0 and about 21% at Mach 7.0 compared to the maximum heat flux for CEV was observed.

  14. Magnet system optimization for segmented adaptive-gap in-vacuum undulator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kitegi, C., E-mail: ckitegi@bnl.gov; Chubar, O.; Eng, C.

    2016-07-27

    Segmented Adaptive Gap in-vacuum Undulator (SAGU), in which different segments have different gaps and periods, promises a considerable spectral performance gain over a conventional undulator with uniform gap and period. According to calculations, this gain can be comparable to the gain achievable with a superior undulator technology (e.g. a room-temperature in-vacuum hybrid SAGU would perform as a cryo-cooled hybrid in-vacuum undulator with uniform gap and period). However, for reaching the high spectral performance, SAGU magnetic design has to include compensation of kicks experienced by the electron beam at segment junctions because of different deflection parameter values in the segments. Wemore » show that such compensation to large extent can be accomplished by using a passive correction, however, simple correction coils are nevertheless required as well to reach perfect compensation over a whole SAGU tuning range. Magnetic optimizations performed with Radia code, and the resulting undulator radiation spectra calculated using SRW code, demonstrating a possibility of nearly perfect correction, are presented.« less

  15. Small Aperture BPM to Quadrupole Assembly Tolerance Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fong, K. W.

    2010-12-07

    The LCLS injector and linac systems utilize a series of quadrupole magnets with a beam position monitor (BPM) captured in the magnet pole tips. The BPM measures the electron beam position by comparing the electrical signal from 4 electrodes and interpolating beam position from these signals. The manufacturing tolerances of the magnet and BPM are critical in determining the mechanical precision of the electrodes relative to the nominal electron beam Z-axis. This study evaluates the statistical uncertainty of the electrodes center axis relative to the nominal electron beam axis.

  16. Cavity BPM with Dipole-Mode-Selective Coupler

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Zenghai; Johnson, Ronald; Smith, Stephen R.

    2006-06-21

    In this paper, we present a novel position sensitive signal pickup scheme for a cavity BPM. The scheme utilizes the H-plane of the waveguide to couple magnetically to the side of the cavity, which results in a selective coupling to the dipole mode and a total rejection of the monopole mode. This scheme greatly simplifies the BPM geometry and relaxes machining tolerances. We will present detailed numerical studies on such a cavity BPM, analyze its resolution limit and tolerance requirements for a nanometer resolution. Finally present the measurement results of a X-band prototype.

  17. RanBPM: a potential therapeutic target for modulating diverse physiological disorders.

    PubMed

    Das, Soumyadip; Suresh, Bharathi; Kim, Hyongbum Henry; Ramakrishna, Suresh

    2017-12-01

    The Ran-binding protein microtubule-organizing center (RanBPM) is a highly conserved nucleocytoplasmic protein involved in a variety of intracellular signaling pathways that control diverse cellular functions. RanBPM interacts with proteins that are linked to various diseases, including Alzheimer's disease (AD), schizophrenia (SCZ), and cancer. In this article, we define the characteristics of the scaffolding protein RanBPM and focus on its interaction partners in diverse physiological disorders, such as neurological diseases, fertility disorders, and cancer. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Overview of recent trends and developments for BPM systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wendt, M.; /Fermilab

    2011-08-01

    Beam position monitoring (BPM) systems are the workhorse of beam diagnostics for almost any kind of charged particle accelerator: linear, circular or transport-lines, operating with leptons, hadrons or heavy ions. BPMs are essential for beam commissioning, accelerator fault analysis and trouble shooting, machine optics, as well as lattice measurements, and finally, for accelerator optimization, in order to achieve the ultimate beam quality. This presentation summarizes the efforts of the beam instrumentation community on recent developments and advances on BPM technologies, i.e. BPM pickup monitors and front-end electronics (analog and digital). Principles, examples, and state-of-the-art status on various BPM techniques, servingmore » hadron and heavy ion machines, sync light synchrotron's, as well as electron linacs for FEL or HEP applications are outlined.« less

  19. RanBPM (RanBP9) regulates mouse c-Kit receptor level and is essential for normal development of bone marrow progenitor cells

    PubMed Central

    Singh, Satyendra; Klarmann, Kimberly D.; Coppola, Vincenzo; Keller, Jonathan R.; Tessarollo, Lino

    2016-01-01

    c-Kit is a tyrosine kinase receptor important for gametogenesis, hematopoiesis, melanogenesis and mast cell biology. Dysregulation of c-Kit function is oncogenic and its expression in the stem cell niche of a number of tissues has underlined its relevance for regenerative medicine and hematopoietic stem cell biology. Yet, very little is known about the mechanisms that control c-Kit protein levels. Here we show that the RanBPM/RanBP9 scaffold protein binds to c-Kit and is necessary for normal c-Kit protein expression in the mouse testis and subset lineages of the hematopoietic system. RanBPM deletion causes a reduction in c-Kit protein but not its mRNA suggesting a posttranslational mechanism. This regulation is specific to the c-Kit receptor since RanBPM reduction does not affect other membrane proteins examined. Importantly, in both mouse hematopoietic system and testis, RanBPM deficiency causes defects consistent with c-Kit loss of expression suggesting that RanBPM is an important regulator of c-Kit function. The finding that this regulatory mechanism is also present in human cells expressing endogenous RanBPM and c-Kit suggests a potential new strategy to target oncogenic c-Kit in malignancies. PMID:27835883

  20. RanBPM (RanBP9) regulates mouse c-Kit receptor level and is essential for normal development of bone marrow progenitor cells.

    PubMed

    Puverel, Sandrine; Kiris, Erkan; Singh, Satyendra; Klarmann, Kimberly D; Coppola, Vincenzo; Keller, Jonathan R; Tessarollo, Lino

    2016-12-20

    c-Kit is a tyrosine kinase receptor important for gametogenesis, hematopoiesis, melanogenesis and mast cell biology. Dysregulation of c-Kit function is oncogenic and its expression in the stem cell niche of a number of tissues has underlined its relevance for regenerative medicine and hematopoietic stem cell biology. Yet, very little is known about the mechanisms that control c-Kit protein levels. Here we show that the RanBPM/RanBP9 scaffold protein binds to c-Kit and is necessary for normal c-Kit protein expression in the mouse testis and subset lineages of the hematopoietic system. RanBPM deletion causes a reduction in c-Kit protein but not its mRNA suggesting a posttranslational mechanism. This regulation is specific to the c-Kit receptor since RanBPM reduction does not affect other membrane proteins examined. Importantly, in both mouse hematopoietic system and testis, RanBPM deficiency causes defects consistent with c-Kit loss of expression suggesting that RanBPM is an important regulator of c-Kit function. The finding that this regulatory mechanism is also present in human cells expressing endogenous RanBPM and c-Kit suggests a potential new strategy to target oncogenic c-Kit in malignancies.

  1. Direct Observation of Ultralow Vertical Emittance using a Vertical Undulator - presentation slides

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wootton, Kent

    2015-09-17

    Direct emittance measurement based on vertical undulator is discussed. Emittance was evaluated from peak ratios, the smallest measured being =0.9 ±0.3 pm rad. The angular distribution of undulator radiation departs from Gaussian approximations, a fact of which diffraction-limited light sources should be aware.

  2. MaRIE Undulator & XFEL Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nguyen, Dinh Cong; Marksteiner, Quinn R.; Anisimov, Petr Mikhaylovich

    The 22 slides in this presentation treat the subject under the following headings: MaRIE XFEL Performance Parameters, Input Electron Beam Parameters, Undulator Design, Genesis Simulations, Risks, and Summary It is concluded that time-dependent Genesis simulations show the MaRIE XFEL can deliver the number of photons within the required bandwidth, provided a number of assumptions are met; the highest risks are associated with the electron beam driving the XFEL undulator; and risks associated with the undulator and/or distributed seeding technique may be evaluated or retired by performing early validation experiments.

  3. Design of a magnetic circuit for a cryogenic undulator in Taiwan photon source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huang, Jui-Che, E-mail: huang.juiche@nsrrc.org.tw; Kuo, Cheng-Ying; Yang, Chin-Kang

    2016-07-27

    The plan for beamlines in Phase II at Taiwan Photon Source is to construct two new BioSAXS and nano-ARPES beamlines. A highly brilliant light source can be produced with a cryogenic undulator, and many synchrotron facilities have been developed and operated with these in their storage rings. The development of a cryogenic undulator became a target for a light source in TPS phase II. A cryogenic undulator with period of length 15 mm will be made in a hybrid magnetic structure, and use PrFeB permanent-magnet materials. A maximum magnetic field 1.31 T is estimated at gap 4 mm and temperaturemore » about 100 K. The spectral performance of a TPS cryogenic undulator is presented in this paper.« less

  4. Simulation Study of the Helical Superconducting Undulator Installation at the Advanced Photon Source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sajaev, V.; Borland, M.; Sun, Y.

    A helical superconducting undulator is planned for installation at the APS. Such an installation would be first of its kind – helical devices were never installed in synchrotron light sources before. Due to its reduced horizontal aperture, a lattice modification is required to accommodate for large horizontal oscillations during injection. We describe the lattice change details and show the new lattice experimental test results. To understand the effect of the undulator on single-particle dynamics, first, its kick maps were computed using different methods. We have found that often-used Elleaume formula* for kick maps gives wrong results for this undulator. Wemore » then used the kick maps obtained by other methods to simulate the effect of the undulator on injection and lifetime.« less

  5. Development of an S-band cavity-type beam position monitor for a high power THz free-electron laser

    NASA Astrophysics Data System (ADS)

    Noh, Seon Yeong; Kim, Eun-San; Hwang, Ji-Gwang; Heo, A.; won Jang, Si; Vinokurov, Nikolay A.; Jeong, Young UK; Hee Park, Seong; Jang, Kyu-Ha

    2015-01-01

    A cavity-type beam position monitor (BPM) has been developed for a compact terahertz (THz) free-electron laser (FEL) system and ultra-short pulsed electron Linac system at the Korea Atomic Energy Research Institute (KAERI). Compared with other types of BPMs, the cavity-type BPM has higher sensitivity and faster response time even at low charge levels. When electron beam passes through the cavity-type BPM, it excites the dipole mode of the cavity of which amplitude depends linearly on the beam offset from the center of the cavity. Signals from the BPM were measured as a function of the beam offset by using an oscilloscope. The microtron accelerator for the KAERI THz FEL produces the electron beam with an energy of 6.5 MeV and pulse length of 5 μs with a micropulse of 10-20 ps at the frequency of 2.801 GHz. The macropulse beam current is 40 mA. Because the microtron provides multi-bunch system, output signal would be the superposition of each single bunch. So high output signal can be obtained from superposition of each single bunch. The designed position resolution of the cavity-type BPM in multi-bunch is submicron. Our cavity-type BPM is made of aluminum and vacuum can be maintained by indium sealing without brazing process, resulting in easy modification and cost saving. The resonance frequency of the cavity-type BPM is 2.803 GHz and the cavity-type BPM dimensions are 200 × 220 mm (length × height) with a pipe diameter of 38 mm. The measured position sensitivity was 6.19 (mV/mm)/mA and the measured isolation between the X and Y axis was -39 dB. By measuring the thermal noise of system, position resolution of the cavity-type BPM was estimated to be less than 1 μm. In this article, we present the test results of the S-band cavity-type BPM and prove the feasibility of the beam position measurement with high resolution using this device.

  6. [Relationship between baseline heart rate and all-cause death in general population].

    PubMed

    Chen, Ji; Chen, Shuo-hua; Liu, Xing; Zhang, Cai-feng; Yao, Tao; Yang, Hui; Wang, Jian-li; Wu, Shou-ling

    2013-06-01

    To investigate the relationship between baseline heart rate(HR) and all-cause death(ACD)in general population. 93 716 workers with heart rate between 40 bpm/min-120 bpm/min and without histories of stroke were selected from the '2006-2007 health examination records' in Kailuan and completed the electrocardiogram exam. Related information were also gathered. These subjects were followed up from July 2006 to December 2010, with the mean time of follow-up as 47.5±4.3 months. During the follow-up period, the occurrence of all-cause death was observed every half a year. (1)The lowest cumulative mortality rate was 1.61% in the group with 60-69 bpm/min. The lowest cumulative mortality rate was 1.78% in the group of 60-69 bpm/min in men. There was no death events observed in women with less than 50 bpm/min and the lowest cumulative mortality rate was 0.60% in the group of 80-89 bpm/min in women. (2)Data from Cox proportional hazard regression analysis showed that the RR(95%CI)of cumulative mortality rates in general population were 1.187 (1.039-1.336), 1.392(1.185-1.636), 1.733(1.404-2.139)and 2.716 (2.171-3.398)in the groups of 70-79, 80-89, 90-99 and ≥100 bpm/min, respectively. The RRs (95% CI) of cumulative mortality in men were 1.227(1.067-1.410), 1.481(1.254-1.750), 1.754 (1.406-2.188)and 2.831 (2.245-3.571) respectively. In women, when comparing with the group of 80-89 bpm/min, the RRs (95%CI)of all-cause death were 0.671(0.568-0.793), 0.825(0.703-0.970) and 1.925 (1.512-2.453)respectively in the groups of 60-69, 70-79 and ≥100 bpm/min. When HR exceeding ≥70 bpm/min, the increase of HR would also increase the rate of ACD. Results of our study also showed a J-shaped curve relation between HR and mortality.

  7. Development of an S-band cavity-type beam position monitor for a high power THz free-electron laser.

    PubMed

    Noh, Seon Yeong; Kim, Eun-San; Hwang, Ji-Gwang; Heo, A; Jang, Si won; Vinokurov, Nikolay A; Jeong, Young U K; Park, Seong Hee; Jang, Kyu-Ha

    2015-01-01

    A cavity-type beam position monitor (BPM) has been developed for a compact terahertz (THz) free-electron laser (FEL) system and ultra-short pulsed electron Linac system at the Korea Atomic Energy Research Institute (KAERI). Compared with other types of BPMs, the cavity-type BPM has higher sensitivity and faster response time even at low charge levels. When electron beam passes through the cavity-type BPM, it excites the dipole mode of the cavity of which amplitude depends linearly on the beam offset from the center of the cavity. Signals from the BPM were measured as a function of the beam offset by using an oscilloscope. The microtron accelerator for the KAERI THz FEL produces the electron beam with an energy of 6.5 MeV and pulse length of 5 μs with a micropulse of 10-20 ps at the frequency of 2.801 GHz. The macropulse beam current is 40 mA. Because the microtron provides multi-bunch system, output signal would be the superposition of each single bunch. So high output signal can be obtained from superposition of each single bunch. The designed position resolution of the cavity-type BPM in multi-bunch is submicron. Our cavity-type BPM is made of aluminum and vacuum can be maintained by indium sealing without brazing process, resulting in easy modification and cost saving. The resonance frequency of the cavity-type BPM is 2.803 GHz and the cavity-type BPM dimensions are 200 × 220 mm (length × height) with a pipe diameter of 38 mm. The measured position sensitivity was 6.19 (mV/mm)/mA and the measured isolation between the X and Y axis was -39 dB. By measuring the thermal noise of system, position resolution of the cavity-type BPM was estimated to be less than 1 μm. In this article, we present the test results of the S-band cavity-type BPM and prove the feasibility of the beam position measurement with high resolution using this device.

  8. Development of an S-band cavity-type beam position monitor for a high power THz free-electron laser

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Noh, Seon Yeong; Kim, Eun-San, E-mail: eskim1@knu.ac.kr; Hwang, Ji-Gwang

    2015-01-15

    A cavity-type beam position monitor (BPM) has been developed for a compact terahertz (THz) free-electron laser (FEL) system and ultra-short pulsed electron Linac system at the Korea Atomic Energy Research Institute (KAERI). Compared with other types of BPMs, the cavity-type BPM has higher sensitivity and faster response time even at low charge levels. When electron beam passes through the cavity-type BPM, it excites the dipole mode of the cavity of which amplitude depends linearly on the beam offset from the center of the cavity. Signals from the BPM were measured as a function of the beam offset by using anmore » oscilloscope. The microtron accelerator for the KAERI THz FEL produces the electron beam with an energy of 6.5 MeV and pulse length of 5 μs with a micropulse of 10-20 ps at the frequency of 2.801 GHz. The macropulse beam current is 40 mA. Because the microtron provides multi-bunch system, output signal would be the superposition of each single bunch. So high output signal can be obtained from superposition of each single bunch. The designed position resolution of the cavity-type BPM in multi-bunch is submicron. Our cavity-type BPM is made of aluminum and vacuum can be maintained by indium sealing without brazing process, resulting in easy modification and cost saving. The resonance frequency of the cavity-type BPM is 2.803 GHz and the cavity-type BPM dimensions are 200 × 220 mm (length × height) with a pipe diameter of 38 mm. The measured position sensitivity was 6.19 (mV/mm)/mA and the measured isolation between the X and Y axis was −39 dB. By measuring the thermal noise of system, position resolution of the cavity-type BPM was estimated to be less than 1 μm. In this article, we present the test results of the S-band cavity-type BPM and prove the feasibility of the beam position measurement with high resolution using this device.« less

  9. Influences on Satisfaction with Reconstructed Breasts and Intimacy in Younger Women Following Bilateral Prophylactic Mastectomy: a Qualitative Analysis.

    PubMed

    Glassey, Rachael; O'Connor, Moira; Ives, Angela; Saunders, Christobel; Hardcastle, Sarah J

    2018-04-30

    The aim of this study was to explore the influences on satisfaction with reconstructed breasts and intimacy following bilateral prophylactic mastectomy (BPM) in younger women (< 35) with a strong family history of breast cancer. Twenty-six women who had undergone BPM between 1 and6 years ago were recruited from New Zealand and Australia through a genetics clinic, registry, research cohort, and online (M age  = 31). Twenty-three were BRCA mutation carriers. Qualitative interviews guided by interpretative phenomenological analysis were conducted. Four themes were identified: satisfaction with breasts before surgery, outcome expectations, type of mastectomy, and open communication. Women who liked their breasts pre-BPM appeared less satisfied with their reconstructed breasts post-surgery, and women who disliked their breasts before BPM were more satisfied with their reconstructed breasts. Women with unrealistic expectations concerning the look and feel of reconstructed breasts were often unhappy with their reconstructed breasts and felt they did not meet their expectations. Unrealistic photos of breast reconstruction and satisfactory communication of realistic outcome expectations by surgeons or psychologists also appeared to influence satisfaction. Communication with partners prior to BPM appeared to improve satisfaction with intimacy post-BPM. The findings suggest that satisfaction with reconstructed breasts for younger women post-BPM appeared to be influenced by realistic outcome expectations and communication with others concerning reconstructed breast appearance and intimacy post-BPM. Implications for practice include discussion of realistic reconstructed breast appearance, referral to a psychologist to discuss sensitive issues, and accurate communication of surgical risks and consequences.

  10. A diminished aortic-cardiac reflex during hypotension in aerobically fit young men

    NASA Technical Reports Server (NTRS)

    Shi, X.; Crandall, C. G.; Potts, J. T.; Williamson, J. W.; Foresman, B. H.; Raven, P. B.

    1993-01-01

    We compared the aortic-cardiac baroreflex sensitivity in eight average fit (AF: VO2max = 44.7 +/- 1.3 ml.kg-1 x min-1) and seven high fit (HF: VO2max = 64.1 +/- 1.7 ml.min-1 x kg-1) healthy young men during hypotension elicited by steady state sodium nitroprusside (SN) infusion. During SN mean arterial pressure (MAP) was similarly decreased in AF (-12.6 +/- 1.0 mm Hg) and HF (-12.1 +/- 1.1 mm Hg). However, the increases in heart rate (HR) were less (P < 0.023) in HF (15 +/- 3 bpm) than AF (25 +/- 1 bpm). When sustained neck suction (NS, -22 +/- 1 torr in AF and -20 +/- 1 torr in HF, P > 0.05) was applied to counteract the decreased carotid sinus transmural pressure during SN, thereby isolating the aortic baroreceptors, the increased HR remained less (P < 0.021) in HF (8 +/- 2 bpm) than AF (16 +/- 2 bpm). During both SN infusion and SN+NS, the calculated gains (i.e., delta HR/delta MAP) were significantly greater in AF (2.1 +/- 0.3 and 1.3 +/- 0.2 bpm.mm Hg-1) than HF (1.2 +/- 0.2 and 0.6 +/- 0.2 bpm.mm Hg-1). However, the estimated carotid-cardiac baroreflex sensitivity (i.e., the gain difference between the stage SN and SN + NS) was not different between AF (0.7 +/- 0.2 bpm.mm Hg-1) and HF (0.6 +/- 0.1 bpm.mm Hg-1). These data indicated that the aortic-cardiac baroreflex sensitivity during hypotension was significantly diminished with endurance exercise training.

  11. Statistical baseline assessment in cardiotocography.

    PubMed

    Agostinelli, Angela; Braccili, Eleonora; Marchegiani, Enrico; Rosati, Riccardo; Sbrollini, Agnese; Burattini, Luca; Morettini, Micaela; Di Nardo, Francesco; Fioretti, Sandro; Burattini, Laura

    2017-07-01

    Cardiotocography (CTG) is the most common non-invasive diagnostic technique to evaluate fetal well-being. It consists in the recording of fetal heart rate (FHR; bpm) and maternal uterine contractions. Among the main parameters characterizing FHR, baseline (BL) is fundamental to determine fetal hypoxia and distress. In computerized applications, BL is typically computed as mean FHR±ΔFHR, with ΔFHR=8 bpm or ΔFHR=10 bpm, both values being experimentally fixed. In this context, the present work aims: to propose a statistical procedure for ΔFHR assessment; to quantitatively determine ΔFHR value by applying such procedure to clinical data; and to compare the statistically-determined ΔFHR value against the experimentally-determined ΔFHR values. To these aims, the 552 recordings of the "CTU-UHB intrapartum CTG database" from Physionet were submitted to an automatic procedure, which consisted in a FHR preprocessing phase and a statistical BL assessment. During preprocessing, FHR time series were divided into 20-min sliding windows, in which missing data were removed by linear interpolation. Only windows with a correction rate lower than 10% were further processed for BL assessment, according to which ΔFHR was computed as FHR standard deviation. Total number of accepted windows was 1192 (38.5%) over 383 recordings (69.4%) with at least an accepted window. Statistically-determined ΔFHR value was 9.7 bpm. Such value was statistically different from 8 bpm (P<;10 -19 ) but not from 10 bpm (P=0.16). Thus, ΔFHR=10 bpm is preferable over 8 bpm because both experimentally and statistically validated.

  12. Resting heart rate associates with one-year risk of major adverse cardiovascular events in patients with acute coronary syndrome after percutaneous coronary intervention.

    PubMed

    Wang, Shao-Li; Wang, Cheng-Long; Wang, Pei-Li; Xu, Hao; Du, Jian-Peng; Zhang, Da-Wu; Gao, Zhu-Ye; Zhang, Lei; Fu, Chang-Geng; Chen, Ke-Ji; Shi, Da-Zhuo

    2016-03-01

    The study was to access the association between resting heart rate (RHR) and one-year risk of major adverse cardiovascular events (MACE) in acute coronary syndrome (ACS) patients after percutaneous coronary intervention (PCI). Patients with ACS after PCI (n = 808) were prospectively followed-up for MACE. RHR was obtained from electrocardiogram. MACE was defined as a composite of cardiac death, nonfatal recurrent myocardial infarction, ischemic-driven revascularization, and ischemic stroke. The association between RHR and one-year risk of MACE was assessed using Cox proportional hazards regression model. Compared with patients with RHR >76 bpm, the adjusted hazard ratio (AHR) was 0.51 (95% confidence intervals [CI]: 0.23-1.14; P = 0.100) for patients with RHR < 61 bpm, and 0.44 (95%CI: 0.23-0.85; P = 0.014) for those with RHR 61-76 bpm. For patients with RHR ≥ 61 bpm, an increase of 10 bpm in RHR was associated with an increase by 38.0% in the risk of MACE (AHR: 1.38; 95% CI: 1.04-1.83; P = 0.026). ACS patients after PCI with RHR >76 bpm were at higher risk of MACE during one-year follow-up compared with patients with RHR 61-76 bpm. An elevated RHR ≥ 61 bpm was associated with increased risk of one-year MACE in ACS patients. © 2015 by the Society for Experimental Biology and Medicine.

  13. Resting heart rate associates with one-year risk of major adverse cardiovascular events in patients with acute coronary syndrome after percutaneous coronary intervention

    PubMed Central

    Wang, Shao-Li; Wang, Cheng-Long; Wang, Pei-Li; Xu, Hao; Du, Jian-Peng; Zhang, Da-Wu; Gao, Zhu-Ye; Zhang, Lei; Fu, Chang-Geng; Chen, Ke-Ji

    2015-01-01

    The study was to access the association between resting heart rate (RHR) and one-year risk of major adverse cardiovascular events (MACE) in acute coronary syndrome (ACS) patients after percutaneous coronary intervention (PCI). Patients with ACS after PCI (n = 808) were prospectively followed-up for MACE. RHR was obtained from electrocardiogram. MACE was defined as a composite of cardiac death, nonfatal recurrent myocardial infarction, ischemic-driven revascularization, and ischemic stroke. The association between RHR and one-year risk of MACE was assessed using Cox proportional hazards regression model. Compared with patients with RHR >76 bpm, the adjusted hazard ratio (AHR) was 0.51 (95% confidence intervals [CI]: 0.23–1.14; P = 0.100) for patients with RHR < 61 bpm, and 0.44 (95%CI: 0.23–0.85; P = 0.014) for those with RHR 61–76 bpm. For patients with RHR ≥ 61 bpm, an increase of 10 bpm in RHR was associated with an increase by 38.0% in the risk of MACE (AHR: 1.38; 95% CI: 1.04–1.83; P = 0.026). ACS patients after PCI with RHR >76 bpm were at higher risk of MACE during one-year follow-up compared with patients with RHR 61–76 bpm. An elevated RHR ≥ 61 bpm was associated with increased risk of one-year MACE in ACS patients. PMID:26585407

  14. Syntheses, crystal structures, and magnetic properties of the oxalato-bridged mixed-valence complexes (FeII(bpm)3]2[FeIII2(ox)5].8H2O and FeII(bpm)3Na(H2O)2Fe(ox)(3).4H2O (bpm = 2,2'-bipyrimidine).

    PubMed

    Armentano, D; De Munno, G; Faus, J; Lloret, F; Julve, M

    2001-02-12

    The preparation and crystal structures of two oxalato-bridged FeII-FeIII mixed-valence compounds, [FeII(bpm)3]2[FeIII2(ox)5].8H2O (1) and FeII(bpm)3Na(H2O)2FeIII(ox)(3).4H2O (2) (bpm = 2,2'-bipyrimidine; ox = oxalate dianion) are reported here. Complex 1 crystallizes in the triclinic system, space group P1, with a = 10.998(2) A, b = 13.073(3) A, c = 13.308(3) A, alpha = 101.95(2) degrees, beta = 109.20(2) degrees, gamma = 99.89(2) degrees, and Z = 1. Complex 2 crystallizes in the monoclinic system, space group P2(1)/c, with a = 12.609(2) A, b = 19.670(5) A, c = 15.843(3) A, beta = 99.46(1) degrees, and Z = 4. The structure of complex 1 consists of centrosymmetric oxalato-bridged dinuclear high-spin iron(III) [Fe2(ox)5]2- anions, tris-chelated low-spin iron(II) [Fe(bpm)3]2+ cations, and lattice water molecules. The iron atoms are hexacoordinated: six oxygen atoms (iron(III)) from two bidentate and one bisbidentate oxalato ligands and six nitrogen atoms (iron(II)) from three bidentate bpm groups. The Fe(III)-O(ox) and Fe(II)-N(bpm) bond distances vary in the ranges 1.967(3)-2.099(3) and 1.967(4)-1.995(3) A, respectively. The iron(III)-iron(III) separation across the bridging oxalato is 5.449(2) A, whereas the shortest intermolecular iron(III)-iron(II) distance is 6.841(2) A. The structure of complex 2 consists of neutral heterotrinuclear Fe(bpm)2Na(H2O)2Fe(ox)3 units and water molecules of crystallization. The tris-chelated low-spin iron(II) ([Fe(bpm)3]2+) and high-spin iron(III) ([Fe(ox)3]3-) entities act as bidentate ligands (through two bpm-nitrogen and two oxalato-oxygen atoms, respectively) toward the univalent sodium cation, yielding the trinuclear (bpm)2Fe(II)-bpm-Na(I)-ox-Fe(III)(ox)2 complex. Two cis-coordinated water molecules complete the distorted octahedral surrounding of the sodium atom. The ranges of the Fe(II)-N(bpm) and Fe(III)-O(ox) bond distances [1.968(6)-1.993(5) and 1.992(6)-2.024(6) A, respectively] compare well with those observed in 1. The Na-N(bpm) bond lengths (2.548(7) and 2.677(7) A) are longer than those of Na-O(ox) (2.514(7) and 2.380(7) A) and Na-O(water) (2.334(15) and 2.356(12) A). The intramolecular Fe(II)...Fe(III) separation is 6.763(2) A, whereas the shortest intermolecular Fe(II)...Fe(II) and Fe(III)...Fe(III) distances are 8.152(2) and 8.992(2) A, respectively. Magnetic susceptibility measurements in the temperature range 2.0-290 K for 1 reveal that the high-spin iron(III) ions are antiferromagnetically coupled (J = -6.6 cm-1, the Hamiltonian being defined as H = -JS1.S2). The magnitude of the antiferromagnetic coupling through the bridging oxalato in the magneto-structurally characterized family of formula [M2(ox)5](2m-10)+ (M = Fe(III) (1), Cr(III), and Ni(II)) is analyzed and discussed by means of a simple orbital model.

  15. Developing cloud-based Business Process Management (BPM): a survey

    NASA Astrophysics Data System (ADS)

    Mercia; Gunawan, W.; Fajar, A. N.; Alianto, H.; Inayatulloh

    2018-03-01

    In today’s highly competitive business environment, modern enterprises are dealing difficulties to cut unnecessary costs, eliminate wastes and delivery huge benefits for the organization. Companies are increasingly turning to a more flexible IT environment to help them realize this goal. For this reason, the article applies cloud based Business Process Management (BPM) that enables to focus on modeling, monitoring and process management. Cloud based BPM consists of business processes, business information and IT resources, which help build real-time intelligence systems, based on business management and cloud technology. Cloud computing is a paradigm that involves procuring dynamically measurable resources over the internet as an IT resource service. Cloud based BPM service enables to address common problems faced by traditional BPM, especially in promoting flexibility, event-driven business process to exploit opportunities in the marketplace.

  16. Maximal heart rate in soccer players: measured versus age-predicted.

    PubMed

    Nikolaidis, Pantelis T

    2015-01-01

    Although maximal heart rate (HR max) is widely used to assess exercise intensity in sport training, and particularly in soccer, there are limited data with regards to the use of age-based prediction equations of HR max in soccer players. The aim of this study was to compare the measured-HR max with two prediction equations (Fox-HR max = 220 - age and Tanaka-HR max = 208 - 0.7 × age) in soccer players. Adolescent (n = 162, 15.8 ± 1.5 years) and adult players (n = 158, 23.4 ± 4.6 years), all members of competitive clubs, voluntarily performed a graded exercise field test (Conconi protocol) to assess HR max . The measured-HR max (197.6 ± 9.4 bpm in total, 200.2 ± 7.9 bpm in adolescent players, and 195.0 ± 10.0 bpm in adult players) was explained by the formula HR max = 212.3 - 0.75 × age (r = -0.41, standard error of the estimate = 8.6). In the total sample, Fox-HR max overestimated measured-HR max [mean difference (95% confidence intervals) = 2.8 bpm (1.6; 3.9)], while Tanaka-HR max underestimated HR max [-3.3 bpm (-4.5; -2.2)]. In adolescents, Fox-HR max overestimated measured-HR max [4.0 bpm (2.5; 5.5)] and Tanaka-HR max underestimated HR max [- 3.2 bpm (-4.7; -1.8)]. In adults, Tanaka-HR max underestimated HR max [-5.0 bpm (-5.3; -4.7)], while there was not any difference between Fox-HR max and measured-HR max [1.6 bpm (-3.4; 0.2)]. The results of this study failed to validate two widely used prediction equations in a large sample of soccer players, indicating the need for a sport-specific equation. On the other hand, the new equation that we presented should be investigated further by future studies before being adopted by coaches and fitness trainers.

  17. Heart rate as an independent risk factor in patients with multiple organ dysfunction: a prospective, observational study.

    PubMed

    Hoke, Robert S; Müller-Werdan, Ursula; Lautenschläger, Christine; Werdan, Karl; Ebelt, Henning

    2012-02-01

    To study the association between baseline heart rate and outcome in patients with multiple organ dysfunction (MODS) as well as the course of heart rate over the first 4 days during MODS. Prospective observational study in 89 patients with MODS, defined as an APACHE-II score ≥20. Baseline heart rate (HR(0)) was determined over a 60-minute period at the time of MODS diagnosis. 28-day all-cause mortality was the primary endpoint of the study, a fall of the APACHE-II score by 4 points or more from day 0 to day 4 constituted the secondary endpoint. Hazard ratios for heart rate of 90 beats per minute (bpm) or greater relative to less than 90 bpm were calculated using Cox proportional hazards model and adjusted for confounding variables. Median baseline heart rate was 83 bpm in survivors and 92 bpm in non-survivors (p = 0.048). 28-day mortality was 32 and 61% in patients with HR(0) < 90 bpm and HR(0) ≥ 90 bpm, respectively. The adjusted hazard ratio for 28-day mortality was 2.30 (95% confidence interval 1.21-4.36, p = 0.001) for HR(0) ≥ 90 bpm relative to HR(0) < 90 bpm. No correlation was found between baseline heart rate and the secondary endpoint. From day 0 to day 4, heart rate remained elevated in all patients, as well as in survivors and non-survivors. A heart rate ≥90 bpm at the time of MODS diagnosis is an independent risk factor for increased 28-day mortality. As in patients with cardiovascular conditions such as coronary heart disease or chronic heart failure, heart rate might constitute a target for heart rate-lowering therapy in the narrow initial treatment window of MODS.

  18. Top-up operation at Pohang Light Source-II

    NASA Astrophysics Data System (ADS)

    Hwang, I.; Huang, J. Y.; Kim, M.; Lee, B.-J.; Kim, C.; Choi, J.-Y.; Kim, M.-H.; Lee, H. S.; Moon, D.; Lee, E. H.; Kim, D.-E.; Nam, S. H.; Shin, S.; Cho, Moohyun

    2014-05-01

    After three years of upgrading work, PLS-II (S. Shin, Commissioning of the PLS-II, JINST, January 2013) is now successfully operating. The top-up operation of the 3 GeV linear accelerator had to be delayed because of some challenges encountered, and PLS-II was run in decay mode at the beginning in March 2012. The main difficulties encountered in the top-up operation of PLS-II are different levels between the linear accelerator and the storage ring, the 14 narrow gap in-vacuum undulators in operation, and the full energy injection by 3 GeV linear accelerator. Large vertical emittance and energy jitter of the linac were the major obstacles that called for careful control of injected beam to reduce beam loss in the storage ring during injection. The following measures were taken to resolve these problems: (1) The high resolution Libera BPM (see http://www.i-tech.si) was implemented to measure the beam trajectory and energy. (2) Three slit systems were installed to filter the beam edge. (3) De-Qing circuit was applied to the modulator system to improve the energy stability of injected beam. As a result, the radiation by beam loss during injection is reduced drastically, and the top-up mode has been successfully operating since 19th March 2013. In this paper, we describe the experimental results of the PLS-II top-up operation and the improvement plan.

  19. The indirect effects on the computation of geoid undulations

    NASA Technical Reports Server (NTRS)

    Wichiencharoen, C.

    1982-01-01

    The indirect effects on the geoid computation due to the second method of Helmert's condensation were studied. when Helmert's anomalies are used in Stokes's equation, there are three types of corrections to the free air geoid. The first correction, the indirect effect on geoid undulation due to the potential change in Helmert's reduction, had a maximum value of 0.51 meters in the test area covering the United States. The second correction, the attraction change effect on geoid undulation, had a maximum value of 9.50 meters when the 10 deg cap was used in Stokes' equation. The last correction, the secondary indirect effect on geoid undulatin, was found negligible in the test area. The corrections were applied to uncorrected free air geoid undulations at 65 Doppler stations in the test area and compared with the Doppler undulations. Based on the assumption that the Doppler coordinate system has a z shift of 4 meters with respect to the geocenter, these comparisons showed that the corrections presented in this study yielded improved values of gravimetric undulations.

  20. Sideband instability analysis based on a one-dimensional high-gain free electron laser model

    NASA Astrophysics Data System (ADS)

    Tsai, Cheng-Ying; Wu, Juhao; Yang, Chuan; Yoon, Moohyun; Zhou, Guanqun

    2017-12-01

    When an untapered high-gain free electron laser (FEL) reaches saturation, the exponential growth ceases and the radiation power starts to oscillate about an equilibrium. The FEL radiation power or efficiency can be increased by undulator tapering. For a high-gain tapered FEL, although the power is enhanced after the first saturation, it is known that there is a so-called second saturation where the FEL power growth stops even with a tapered undulator system. The sideband instability is one of the primary reasons leading to this second saturation. In this paper, we provide a quantitative analysis on how the gradient of undulator tapering can mitigate the sideband growth. The study is carried out semianalytically and compared with one-dimensional numerical simulations. The physical parameters are taken from Linac Coherent Light Source-like electron bunch and undulator systems. The sideband field gain and the evolution of the radiation spectra for different gradients of undulator tapering are examined. It is found that a strong undulator tapering (˜10 %) provides effective suppression of the sideband instability in the postsaturation regime.

  1. A beating heart cell model to predict cardiotoxicity: effects of the dietary supplement ingredients higenamine, phenylethylamine, ephedrine and caffeine.

    PubMed

    Calvert, Richard; Vohra, Sanah; Ferguson, Martine; Wiesenfeld, Paddy

    2015-04-01

    Some dietary supplements may contain cardiac stimulants and potential cardiotoxins. In vitro studies may identify ingredients of concern. A beating human cardiomyocyte cell line was used to evaluate cellular effects following phenylethylamine (PEA), higenamine, ephedrine or caffeine treatment. PEA and higenamine exposure levels simulated published blood levels in humans or animals after intravenous administration. Ephedrine and caffeine levels approximated published blood levels following human oral intake. At low or midrange levels, each chemical was examined plus or minus 50 µM caffeine, simulating human blood levels reported after consumption of caffeine-enriched dietary supplements. To measure beats per minute (BPM), peak width, etc., rhythmic rise and fall in intracellular calcium levels following 30 min of treatment was examined. Higenamine 31.3 ng/ml or 313 ng/ml significantly increased BPM in an escalating manner. PEA increased BPM at 0.8 and 8 µg/ml, while 80 µg/ml PEA reduced BPM and widened peaks. Ephedrine produced a significant BPM dose response from 0.5 to 5.0 µM. Caffeine increased BPM only at a toxic level of 250 µM. Adding caffeine to PEA or higenamine but not ephedrine further increased BPM. These in vitro results suggest that additional testing may be warranted in vivo to further evaluate these effects. Published by Elsevier Ltd.

  2. UNDULATOR-BASED LASER WAKEFIELD ACCELERATOR ELECTRON BEAM DIAGNOSTIC

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bakeman, M.S.; Fawley, W.M.; Leemans, W. P.

    to couple the THUNDER undulator to the LOASIS Lawrence Berkeley National Laboratory (LBNL) laser wakefield accelerator (LWFA). Currently the LWFA has achieved quasi-monoenergetic electron beams with energies up to 1 GeV. These ultra-short, high-peak-current, electron beams are ideal for driving a compact XUV free electron laser (FEL). Understanding the electron beam properties such as the energy spread and emittance is critical for achieving high quality light sources with high brightness. By using an insertion device such as an undulator and observing changes in the spontaneous emission spectrum, the electron beam energy spread and emittance can be measured with high precision.more » The initial experiments will use spontaneous emission from 1.5 m of undulator. Later experiments will use up to 5 m of undulator with a goal of a high gain, XUV FEL.« less

  3. 75 FR 57410 - Address Correction Notices for Letters and Flats Qualifying for Full-Service Intelligent Mail and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-21

    ... First-Class Mail[supreg], Standard Mail[supreg], and Bound Printed Matter (BPM) pieces that are eligible...-Class Mail, Standard Mail, or BPM prices. This change will coincide with the current Move Update... First-Class Mail, Standard Mail, and BPM full-service pieces. Prices for notices provided after this...

  4. Observation of an optical vortex beam from a helical undulator in the XUV region.

    PubMed

    Kaneyasu, Tatsuo; Hikosaka, Yasumasa; Fujimoto, Masaki; Iwayama, Hiroshi; Hosaka, Masahito; Shigemasa, Eiji; Katoh, Masahiro

    2017-09-01

    The observation of an optical vortex beam at 60 nm wavelength, produced as the second-harmonic radiation from a helical undulator, is reported. The helical wavefront of the optical vortex beam was verified by measuring the interference pattern between the vortex beam from a helical undulator and a normal beam from another undulator. Although the interference patterns were slightly blurred owing to the relatively large electron beam emittance, it was possible to observe the interference features thanks to the helical wavefront of the vortex beam. The experimental results were well reproduced by simulation.

  5. Factors associated with sinus bradycardia during crizotinib treatment: a retrospective analysis of two large-scale multinational trials (PROFILE 1005 and 1007).

    PubMed

    Ou, Sai-Hong Ignatius; Tang, Yiyun; Polli, Anna; Wilner, Keith D; Schnell, Patrick

    2016-04-01

    Decreases in heart rate (HR) have been described in patients receiving crizotinib. We performed a large retrospective analysis of HR changes during crizotinib therapy. HRs from vital-sign data for patients with anaplastic lymphoma kinase (ALK)-positive nonsmall cell lung cancer enrolled in PROFILE 1005 and the crizotinib arm of PROFILE 1007 were analyzed. Sinus bradycardia (SB) was defined as HR <60 beats per minute (bpm). Magnitude and timing of HR changes were assessed. Potential risk factors for SB were investigated by logistic regression analysis. Progression-free survival (PFS) was evaluated according to HR decrease by <20 versus ≥ 20 bpm within the first 50 days of starting treatment. For the 1053 patients analyzed, the mean maximum postbaseline HR decrease was 25 bpm (standard deviation 15.8). Overall, 441 patients (41.9%) had at least one episode of postbaseline SB. The mean precrizotinib treatment HR was significantly lower among patients with versus without postbaseline SB (82.2 bpm vs. 92.6 bpm). The likelihood of experiencing SB was statistically significantly higher among patients with a precrizotinib treatment HR <70 bpm. PFS was comparable among patients with or without HR decrease of ≥ 20 bpm within the first 50 days of starting crizotinib. Decrease in HR is very common among patients on crizotinib. The likelihood of experiencing SB was statistically significantly higher among patients with a precrizotinib treatment HR <70 bpm. This is the first large-scale report investigating the association between treatment with a tyrosine kinase inhibitor and the development of bradycardia. HRs should be closely monitored during crizotinib treatment. © 2016 The Authors. Cancer Medicine published by John Wiley & Sons Ltd.

  6. Validation of a new algorithm for the BPM-100 electronic oscillometric office blood pressure monitor.

    PubMed

    Wright, J M; Mattu, G S; Perry, T L; Gelferc, M E; Strange, K D; Zorn, A; Chen, Y

    2001-06-01

    To test the accuracy of a new algorithm for the BPM-100, an automated oscillometric blood pressure (BP) monitor, using stored data from an independently conducted validation trial comparing the BPM-100(Beta) with a mercury sphygmomanometer. Raw pulse wave and cuff pressure data were stored electronically using embedded software in the BPM-100(Beta), during the validation trial. The 391 sets of measurements were separated objectively into two subsets. A subset of 136 measurements was used to develop a new algorithm to enhance the accuracy of the device when reading higher systolic pressures. The larger subset of 255 measurements (three readings for 85 subjects) was used as test data to validate the accuracy of the new algorithm. Differences between the new algorithm BPM-100 and the reference (mean of two observers) were determined and expressed as the mean difference +/- SD, plus the percentage of measurements within 5, 10, and 15 mmHg. The mean difference between the BPM-100 and reference systolic BP was -0.16 +/- 5.13 mmHg, with 73.7% < or = 5 mmHg, 94.9% < or = 10 mmHg and 98.8% < or = 15 mmHg. The mean difference between the BPM-100 and reference diastolic BP was -1.41 +/- 4.67 mmHg, with 78.4% < or = 5 mmHg, 92.5% < or = 10 mmHg, and 99.2% < or = 15 mmHg. These data improve upon that of the BPM-100(Beta) and pass the AAMI standard, and 'A' grade BHS protocol. This study illustrates a new method for developing and testing a change in an algorithm for an oscillometric BP monitor utilizing collected and stored electronic data and demonstrates that the new algorithm meets the AAMI standard and BHS protocol.

  7. Comparison of the oscillometric blood pressure monitor (BPM-100(Beta) ) with the auscultatory mercury sphygmomanometer.

    PubMed

    Mattu, G S; Perry, T L; Wright, J M

    2001-06-01

    To compare directly the accuracy of the BPM-100(Beta) monitor (an automated oscillometric blood pressure device) with standard auscultatory mercury sphygmomanometry. The BPM-100(Beta) was connected in parallel via a T-tube to a mercury sphygmomanometer. The BPM-100(Beta) and two trained observers (blinded from each other and from the BPM-100(Beta)) measured the sitting blood pressure simultaneously. Means, standard deviations and ranges were calculated for all the demographic data: age, arm size, heart rate and blood pressure. The agreement between the BPM-100(Beta) and the mean of two observers (the reference) was determined and expressed as the mean +/- SD, as well as the percentage of differences falling within 5, 10 and 15 mmHg. Of the 92 subjects recruited, 85 (92.4%) met the inclusion criteria, and 391 sets of sitting blood pressure and heart rate measurements were available for analysis. The mean difference between the BPM-100(Beta) monitor and the reference was -0.62 +/- 6.96 mmHg for systolic blood pressure, -1.48 +/- 4.80 mmHg for diastolic blood pressure and 0.14 +/- 1.86 beats/min for heart rate. The only limitation of the device was its tendency to underestimate higher systolic blood pressures. This problem has been addressed by a minor change in the algorithm (see the companion publication, Blood Press Monit, 6, 161-165, 2001). The BPM-100(Beta) is an accurate blood pressure monitor for the office setting, meeting all requirements of the Association for the Advancement of Medical Instrumentation and achieving an 'A' grade according to the British Hypertension Society protocol.

  8. Relationship between heart rate and quiescent interval of the cardiac cycle in children using MRI.

    PubMed

    Zhang, Wei; Bogale, Saivivek; Golriz, Farahnaz; Krishnamurthy, Rajesh

    2017-11-01

    Imaging the heart in children comes with the challenge of constant cardiac motion. A prospective electrocardiography-triggered CT scan allows for scanning during a predetermined phase of the cardiac cycle with least motion. This technique requires knowing the optimal quiescent intervals of cardiac cycles in a pediatric population. To evaluate high-temporal-resolution cine MRI of the heart in children to determine the relationship of heart rate to the optimal quiescent interval within the cardiac cycle. We included a total of 225 consecutive patients ages 0-18 years who had high-temporal-resolution cine steady-state free-precession sequence performed as part of a magnetic resonance imaging (MRI) or magnetic resonance angiography study of the heart. We determined the location and duration of the quiescent interval in systole and diastole for heart rates ranging 40-178 beats per minute (bpm). We performed the Wilcoxon signed rank test to compare the duration of quiescent interval in systole and diastole for each heart rate group. The duration of the quiescent interval at heart rates <80 bpm and >90 bpm was significantly longer in diastole and systole, respectively (P<.0001 for all ranges, except for 90-99 bpm [P=.02]). For heart rates 80-89 bpm, diastolic interval was longer than systolic interval, but the difference was not statistically significant (P=.06). We created a chart depicting optimal quiescent intervals across a range of heart rates that could be applied for prospective electrocardiography-triggered CT imaging of the heart. The optimal quiescent interval at heart rates <80 bpm is in diastole and at heart rates ≥90 bpm is in systole. The period of quiescence at heart rates 80-89 bpm is uniformly short in systole and diastole.

  9. Association of Fetal Heart Rate Baseline Change and Neonatal Outcomes.

    PubMed

    Yang, Michael; Stout, Molly J; López, Julia D; Colvin, Ryan; Macones, George A; Cahill, Alison G

    2017-07-01

    Objective  The objective of this study was to describe the incidence of baseline change within normal range during labor and its prediction of neonatal outcomes. Materials and Methods  This was a prospective cohort of singleton, nonanomalous, term neonates with continuous electronic fetal monitoring and normal baseline fetal heart rate throughout the last 2 hours of labor. We determined baseline in 10-minute segments using Eunice Kennedy Shriver National Institute of Child Health and Human Development criteria. We evaluated baseline changes of ≥ 20 and ≥ 30 bpm for association with acidemia (umbilical cord arterial pH ≤ 7.10) and neonatal intensive care unit (NICU) admission. Finally, we performed a sensitivity analysis of normal neonates, excluding those with acidemia, NICU admission, or 5-minute Apgar < 4. Results  Among all neonates ( n  = 3,021), 1,267 (41.9%) had change ≥ 20 bpm; 272 (9.0%) had ≥ 30 bpm. Among normal neonates ( n  = 2,939), 1,221 (41.5%) had change ≥20 bpm. Acidemia was not associated with baseline change of any direction or magnitude. NICU admission was associated with decrease ≥ 20 bpm (adjusted odds ratio [aOR]: 2.93; 95% confidence interval [CI]: 1.19 - 7.21) or any direction ≥ 20 bpm (aOR: 4.06; 95% CI: 1.46-11.29). For decrease ≥ 20 bpm, sensitivity and specificity were 40.0 and 81.7%; for any direction ≥ 20 bpm, 75.0 and 58.3%. Conclusion  Changes of normal baseline are common in term labor and poorly predict morbidity, regardless of direction or magnitude. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  10. Characterization and predictors of first and subsequent inappropriate ICD therapy by heart rate ranges: Result of the MADIT-RIT efficacy analysis.

    PubMed

    Kutyifa, Valentina; Daubert, James P; Olshansky, Brian; Huang, David T; Zhang, Claire; Ruwald, Anne-Christine H; McNitt, Scott; Zareba, Wojciech; Moss, Arthur J; Schuger, Claudio

    2015-09-01

    Data on inappropriate implantable cardioverter-defibrillator (ICD) therapy and effects of programming by heart rate are lacking. We aimed to characterize inappropriate ICD therapy and assess the effects of novel programming by heart rate. Incidence and causes of inappropriate therapy by heart rate range (below or above 200 bpm) were assessed. Predictors of inappropriate therapy and effects of programming by heart rate were evaluated with multivariate Cox regression models. Crossovers were excluded. Inappropriate therapy occurred in 9.2% of the total patient population, with 19% of patients randomized to study arm A, 3.6% in arm B, and 4.7% in arm C. Inappropriate therapies <200 bpm were attributable to supraventricular tachycardia (SVT)/sinus tachycardia (78%) or atrial fibrillation/flutter (20%). Inappropriate therapy ≥200 bpm occurred because of SVT (47%), atrial fibrillation/flutter (41%), or electromagnetic interference (13%). Conventional ICD programming was associated with more inappropriate therapy <200 bpm than high-rate or delayed therapy, as were younger age, history of atrial arrhythmia, advanced New York Heart Association functional class, ICD versus cardiac resynchronization therapy with defibrillator, and absence of diabetes. High-rate and long-delay therapy significantly reduced the risk of inappropriate therapy in the <200 bpm range. Long delay was associated with further reduction of fast (≥200 bpm) inappropriate therapy (P = .032) and a reduction in subsequent inappropriate episodes (P = .006). In MADIT-RIT, inappropriate ICD therapy is most frequent at rates below 200 bpm and can be predicted, and effectively prevented, with high-rate cutoff programming. Long-delay therapy effectively reduces fast inappropriate therapy ≥200 bpm and subsequent events. [ http://clinicaltrials.gov/ct2/show/NCT00947310]. Copyright © 2015 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  11. Enhancement of absorption and resistance of motion utilizing a multi-channel opto-electronic sensor to effectively monitor physiological signs during sport exercise

    NASA Astrophysics Data System (ADS)

    Alzahrani, Abdullah; Hu, Sijung; Azorin-Peris, Vicente; Barrett, Laura; Esliger, Dale; Hayes, Matthew; Akbare, Shafique; Achart, Jérôme; Kuoch, Sylvain

    2015-03-01

    This study presents an effective engineering approach for human vital signs monitoring as increasingly demanded by personal healthcare. The aim of this work is to study how to capture critical physiological parameters efficiently through a well-constructed electronic system and a robust multi-channel opto-electronic patch sensor (OEPS), together with a wireless communication. A unique design comprising multi-wavelength illumination sources and a rapid response photo sensor with a 3-axis accelerometer enables to recover pulsatile features, compensate motion and increase signal-to-noise ratio. An approved protocol with designated tests was implemented at Loughborough University a UK leader in sport and exercise assessment. The results of sport physiological effects were extracted from the datasets of physical movements, i.e. sitting, standing, waking, running and cycling. t-test, Bland-Altman and correlation analysis were applied to evaluate the performance of the OEPS system against Acti-Graph and Mio-Alpha.There was no difference in heart rate measured using OEPS and both Acti-Graph and Mio-Alpha (both p<0.05). Strong correlations were observed between HR measured from the OEPS and both the Acti-graph and Mio-Alpha (r = 0.96, p<0.001). Bland-Altman analysis for the Acti-Graph and OEPS found the bias 0.85 bpm, the standard deviation 9.20 bpm, and the limits of agreement (LOA) -17.18 bpm to +18.88 bpm for lower and upper limits of agreement respectively, for the Mio-Alpha and OEPS the bias is 1.63 bpm, standard deviation SD8.62 bpm, lower and upper limits of agreement, - 15.27 bpm and +18.58 bpm respectively. The OEPS demonstrates a real time, robust and remote monitoring of cardiovascular function.

  12. Numerical analysis of the beam position monitor pickup for the Iranian light source facility

    NASA Astrophysics Data System (ADS)

    Shafiee, M.; Feghhi, S. A. H.; Rahighi, J.

    2017-03-01

    In this paper, we describe the design of a button type Beam Position Monitor (BPM) for the low emittance storage ring of the Iranian Light Source Facility (ILSF). First, we calculate sensitivities, induced power and intrinsic resolution based on solving Laplace equation numerically by finite element method (FEM), in order to find the potential at each point of BPM's electrode surface. After the optimization of the designed BPM, trapped high order modes (HOM), wakefield and thermal loss effects are calculated. Finally, after fabrication of BPM, it is experimentally tested by using a test-stand. The results depict that the designed BPM has a linear response in the area of 2×4 mm2 inside the beam pipe and the sensitivity of 0.080 and 0.087 mm-1 in horizontal and vertical directions. Experimental results also depict that they are in a good agreement with numerical analysis.

  13. Validation of PEP-II Resonantly Excited Turn-by-Turn BPM Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yan, Yiton T.; Cai, Yunhai; Colocho, William.

    2007-06-28

    For optics measurement and modeling of the PEP-II electron (HER) and position (LER) storage rings, we have been doing well with MIA [1] which requires analyzing turn-by-turn Beam Position Monitor (BPM) data that are resonantly excited at the horizontal, vertical, and longitudinal tunes. However, in anticipation that certain BPM buttons and even pins in the PEP-II IR region would be missing for the run starting in January 2007, we had been developing a data validation process to reduce the effect due to the reduced BPM data accuracy on PEP-II optics measurement and modeling. Besides the routine process for ranking BPMmore » noise level through data correlation among BPMs with a singular-value decomposition (SVD), we could also check BPM data symplecticity by comparing the invariant ratios. Results from PEP-II measurement will be presented.« less

  14. Preliminary Analysis of a 27.5 mm Period Undulator for the MBA Lattice

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abliz, M.; Grimmer, J.

    2016-07-27

    The magnetic design of a 27.5 mm period undulator was performed for the APS MBA Lattice. One purpose of the magnetic design was to decrease the magnetic force in order to operate the undulator successfully at a smaller gap compared to the existing 27 mm undulator at the APS. As a result, the magnetic force is decreased by about 18% at a gap of 11 mm and the total volume of the magnet and the pole is decreased by approximately 22% with the new model. The calculated effective field with the new model was 172 G higher than the existingmore » 27-mm period undulator with a gap of 11 mm. The calculated field roll-off with the new optimized model is within the requirements of the MBA, in the range of ± 5 mm.« less

  15. Power spectra of geoid undulations. [definition of altimeter design requirements for geoid recovery

    NASA Technical Reports Server (NTRS)

    Brown, R. D.

    1975-01-01

    Data from spacecraft altimeters are expected to contribute to an improved determination of the marine geoid. To better define altimeter system design requirements for geoid recovery, amplitudes of geoid undulations at short wavelengths were examined. Models of detailed geoids in selected areas around the earth, developed from a combination of satellite derived spherical harmonics and 1 deg-by-1 deg area mean free-air gravity anomalies, were subjected to a spectral analysis. The resulting undulation power spectra were compared to existing estimates for the magnitude of geoid undulations at short wavelengths. The undulation spectra were found to be consistent with Kaula's rule of thumb, following an inverse third power relationship with spatial frequency for wavelengths at least as small as 300 km. The requirements imposed by this relationship on altimeter accuracy, data rate, and horizontal resolution to meet the goal of a detailed geoid description are discussed.

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    TREMAINE,A.; MUROKH,A.; WANG,X.J.

    The VISA experiment is designed to reach and study saturation in a high gain 800nm SASE FEL at the Brookhaven Accelerator Test Facility (ATF). To do this, the undulator must be aligned at first to within 20 {micro}m with use of a laser interferometric system. Once aligned, any small movements from the aligned position will greatly detriment the SASE FEL performance thus making continuous monitoring of the undulator position necessary. This is quite a complicated task since the 4m undulator is made up of four 1m sections enclosed in a vacuum chamber. We have developed an in situ optical systemmore » to monitor the undulator position with an accuracy better than 10 {micro}m. In addition, we have demonstrated the accuracy of this system by bringing the grossly misaligned VISA undulator ({approximately} 500 {micro}m in some locations) into alignment and attaining very high gain of the SASE FEL.« less

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    As part of the R and D program towards a fourth generation light source, a Self-Amplified Spontaneous Emission (SASE) demonstration is being prepared. The Visible-Infrared SASE Amplifier (VISA) undulator will be installed at Brookhaven National Laboratory by the end of the year. The VISA undulator is an in-vacuum, 4-meter long, 1.8 cm period, pure-permanent magnet device, with a novel, strong focusing, permanent magnet FODO array included within the fixed, 6 mm undulator gap. The undulator is constructed of 99 cm long segments. To attain maximum SASE gain requires establishing overlap of electron and photon beams to within 50 {micro}m rms.more » This imposes challenging tolerances on mechanical fabrication and magnetic field quality, and necessitates use of laser straightness interferometry for calibration and alignment of the magnetic axes of the undulator segments. This paper describes the magnetic centerline determination, and the fiducialization and alignment processes which were performed to meet the tolerance goal.« less

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ruland, Robert E.

    As part of the R and D program towards a fourth generation light source, a Self-Amplified Spontaneous Emission (SASE) demonstration is being prepared. The Visible-Infrared SASE Amplifier (VISA) undulator is being installed at Brookhaven National Laboratory. The VISA undulator is an in-vacuum, 4-meter long, 1.8 cm period, pure-permanent magnet device, with a novel, strong focusing, permanent magnet FODO array included within the fixed, 6 mm undulator gap. The undulator is constructed of 99 cm long segments. To attain maximum SASE gain requires establishing overlap of electron and photon beams to within 50 pm rms. This imposes challenging tolerances on mechanicalmore » fabrication and magnetic field quality, and necessitates use of laser straightness interferometry for calibration and alignment of the magnetic axes of the undulator segments. This paper describes the magnetic centerline determination, and the fiducialization and alignment processes, which were performed to meet the tolerance goal.« less

  19. High-temperature superconducting undulator magnets

    DOE PAGES

    Kesgin, Ibrahim; Kasa, Matthew; Ivanyushenkov, Yury; ...

    2017-02-13

    Here, this paper presents test results on a prototype superconducting undulator magnet fabricated using 15% Zr-doped rare-earth barium copper oxide high temperature superconducting (HTS) tapes. On an 11-pole magnet we demonstrate an engineering current density, J e, of more than 2.1 kA mm -2 at 4.2 K, a value that is 40% higher than reached in comparable devices wound with NbTi-wire, which is used in all currently operating superconducting undulators. A novel winding scheme enabling the continuous winding of tape-shaped conductors into the intricate undulator magnets as well as a partial interlayer insulation procedure were essential in reaching this advancemore » in performance. Currently, there are rapid advances in the performance of HTS; therefore, achieving even higher current densities in an undulator structure or/and operating it at temperatures higher than 4.2 K will be possible, which would substantially simplify the cryogenic design and reduce overall costs.« less

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    MUROKH,A.; FRIGOLA,P.; ET AL

    We describe a diagnostics system developed, to measure exponential gain properties and the electron beam dynamics inside the strong focusing 4-m long undulator for the VISA (Visible to Infrared SASE Amplifier) FEL. The technical challenges included working inside the small undulator gap, optimizing the electron beam diagnostics in the high background environment of the spontaneous undulator radiation, multiplexing and transporting the photon beam. Initial results are discussed.

  1. Irradiation caused performance losses of undulators equipped with Sm2Co17 magnets

    NASA Astrophysics Data System (ADS)

    Heidrich, S.; Aulenbacher, K.; Donders, S.; Nikipelov, A.

    2018-06-01

    The effects of beam losses on the performance of undulators equipped with Sm2Co17 magnets were investigated at the 855 MeV beamline of the Mainzer Microtron MAMI. Therefore, different cases containing undulator components as well as complete undulator assemblies were irradiated. Different types of shielding were used to distinguish the magnetic field degradation caused by neutrons from the degradation caused by electrons and photons. The results of each case were put in relation with the expected beam losses of a conceptional 10 kW free-electron-laser (FEL) based on an electron beam with 34 MW beam power.

  2. Generation of a wakefield undulator in plasma with transverse density gradient

    DOE PAGES

    Stupakov, Gennady V.

    2017-11-30

    Here, we show that a short relativistic electron beam propagating in a plasma with a density gradient perpendicular to the direction of motion generates a wakefield in which a witness bunch experiences a transverse force. A density gradient oscillating along the beam path would create a periodically varying force$-$an undulator, with an estimated strength of the equivalent magnetic field more than ten Tesla. This opens an avenue for creation of a high-strength, short-period undulators, which eventually may lead to all-plasma, free electron lasers where a plasma wakefield acceleration is naturally combined with a plasma undulator in a unifying, compact setup.

  3. Perspectives on micropole undulators in synchrotron radiation technology

    NASA Astrophysics Data System (ADS)

    Tatchyn, Roman; Csonka, Paul; Toor, Arthur

    1989-07-01

    Micropole undulators promise to advance synchrotron radiation (SR) technology in two distinct ways. The first is in the development of economical, low-energy storage rings, or linacs, as soft x-ray sources, and the second is in the opening up of gamma-ray spectral ranges on high-energy storage rings. In this paper the promise and current status of micropole undulator (MPU) technology are discussed, and a review of some practical obstacles to the implementation of MPU's on present-day storage rings is given. Some successful results of recent performance measurements of micropole undulators on the Lawrence Livermore National Laboratory linac are briefly summarized.

  4. A noncoherent model for microwave emissions and backscattering from the sea surface

    NASA Technical Reports Server (NTRS)

    Wu, S. T.; Fung, A. K.

    1973-01-01

    The two-scale (small irregularities superimposed upon large undulations) scattering theory proposed by Semyonov was extended and used to compute microwave apparent temperature and the backscattering cross section from ocean surfaces. The effect of the small irregularities upon the scattering characteristics of the large undulations is included by modifying the Fresnel reflection coefficients; whereas the effect of the large undulations upon those of the small irregularities is taken into account by averaging over the surface normals of the large undulations. The same set of surface parameters is employed for a given wind speed to predict both the scattering and the emission characteristics at both polarizations.

  5. Generation of a wakefield undulator in plasma with transverse density gradient

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stupakov, Gennady V.

    Here, we show that a short relativistic electron beam propagating in a plasma with a density gradient perpendicular to the direction of motion generates a wakefield in which a witness bunch experiences a transverse force. A density gradient oscillating along the beam path would create a periodically varying force$-$an undulator, with an estimated strength of the equivalent magnetic field more than ten Tesla. This opens an avenue for creation of a high-strength, short-period undulators, which eventually may lead to all-plasma, free electron lasers where a plasma wakefield acceleration is naturally combined with a plasma undulator in a unifying, compact setup.

  6. Magnetic force study for the helical afterburner for the European XFEL

    NASA Astrophysics Data System (ADS)

    Li, Peng; Wei, Tao; Li, Yuhui; Pflueger, Joachim

    2017-05-01

    At present the SASE3 undulator line at the European XFEL is using a planar undulator producing linear polarized soft Xray radiation only. In order to satisfy the demand for circular polarized radiation a helical undulator system, the so-called afterburner is in construction. It will be operated as a radiator using the pre-bunched beam of the SASE3 undulator system. Among several options for the magnetic structure the Apple-X geometry was chosen. This is a pure permanent magnet undulator using NdFeB material. Four magnet arrays are arranged symmetrically the beam axis. Polarization can be changed by adjusting the phase shift (PS) between the two orthogonal structures. The field strength can be adjusted either by gap adjustment or alternatively by the amplitude shift (AS) scheme. For an engineering design the maximum values of forces and torques on each of the components under worst case operational conditions are important. The superposition principle is used to reduce calculation time. It is found that the maximum forces Fx, Fy and Fz for a 2m long Apple-X undulator are 1.8*104N, 2.4*104N and 2.3*104N, respectively. More results are presented in this paper.

  7. Geoid undulation computations at laser tracking stations

    NASA Technical Reports Server (NTRS)

    Despotakis, Vasilios K.

    1987-01-01

    Geoid undulation computations were performed at 29 laser stations distributed around the world using a combination of terrestrial gravity data within a cap of radius 2 deg and a potential coefficient set up to 180 deg. The traditional methods of Stokes' and Meissl's modification together with the Molodenskii method and the modified Sjoberg method were applied. Performing numerical tests based on global error assumptions regarding the terrestrial data and the geopotential set it was concluded that the modified Sjoberg method is the most accurate and promising technique for geoid undulation computations. The numerical computations for the geoid undulations using all the four methods resulted in agreement with the ellipsoidal minus orthometric value of the undulations on the order of 60 cm or better for most of the laser stations in the eastern United States, Australia, Japan, Bermuda, and Europe. A systematic discrepancy of about 2 meters for most of the western United States stations was detected and verified by using two relatively independent data sets. For oceanic laser stations in the western Atlantic and Pacific oceans that have no terrestrial data available, the adjusted GEOS-3 and SEASAT altimeter data were used for the computation of the geoid undulation in a collocation method.

  8. Association of heart rate at hospital discharge with mortality and hospitalizations in patients with heart failure.

    PubMed

    Habal, Marlena V; Liu, Peter P; Austin, Peter C; Ross, Heather J; Newton, Gary E; Wang, Xuesong; Tu, Jack V; Lee, Douglas S

    2014-01-01

    Heart failure (HF) is associated with a high burden of morbidity and mortality. Hospital discharge is an opportunity for identification of modifiable prognostic factors in the transition to chronic HF. We examined the association of discharge heart rate with 30-day and 1-year mortality and hospitalization outcomes in a cohort of 9097 patients with HF discharged from hospital. Discharge heart rate was categorized into predefined groups: 40 to 60 (n=1333), 61 to 70 (n=2170), 71 to 80 (n=2631), 81 to 90 (n=1700), and >90 bpm (n=1263). There was a significant increase in all-cause 30-day mortality with adjusted odds ratios of 1.59 (95% confidence interval [CI], 1.18-2.14; P=0.003) for discharge heart rates 81 to 90 bpm and 1.56 (95% CI, 1.13-2.16; P=0.007) for heart rates>90 bpm when compared with the reference group (heart rates, 61-70 bpm). Cardiovascular death risk at 30 days was also higher with adjusted odds ratio 1.59 (discharge heart rates, 81-90 bpm; 95% CI, 1.09-2.33; P=0.017) and 1.65 (discharge heart rates, >90 bpm; 95% CI, 1.09-2.48; P=0.017). One-year all-cause mortality (adjusted odds ratio, 1.41; 95% CI, 1.16-1.72; P<0.001) and cardiovascular death (adjusted odds ratio, 1.47; 95% CI, 1.12-1.92; P=0.005) were higher with discharge heart rates>90 bpm when compared with the reference group (heart rates, 40-60 bpm). Readmissions for HF (adjusted hazard ratio, 1.26; 95% CI, 1.04-1.54; P=0.021) and cardiovascular disease (adjusted hazard ratio, 1.29; 95% CI, 1.08-1.54; P=0.004) within 30 days were also higher with discharge heart rates>90 bpm. Higher discharge heart rates were associated with greater risk of all-cause and cardiovascular mortality≤1-year follow-up and an elevated risk of 30-day readmission for HF and cardiovascular disease.

  9. Status of the ATF Damping Ring BPM Upgrade Project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Briegel, C.; /Fermilab; Eddy, N.

    2011-12-01

    A substantial upgrade of the beam position monitors (BPM) at the ATF (Accelerator Test Facility) damping ring is currently in progress. Implementing digital read-out signal processing techniques in line with an optimized, low-noise analog downconverter, a resolution well below 1 mum could be demonstrated at 20 (of 96) upgraded BPM stations. The narrowband, high resolution BPM mode permits investigation of all types of non-linearities, imperfections and other obstacles in the machine which may limit the very low target aimed vertical beam emittance of < 2 pm. The technical status of the project, first beam measurements and an outlook to it'smore » finalization are presented.« less

  10. The Tribology of Undulated Surfaces

    DTIC Science & Technology

    1989-05-30

    wear, in effect by decreasing the impact of plowing. Lubrication, hard coatings, fiber-reinforced composites are but a few examples. All these methods ha...In addition, the effects of pad width and cavity volume fraction of the undulated surface were also investigated. A plowing model proposed for...boundary lubricated sliding is in good agreement with experimental results. It is suggested, furthermore, that the undulated surfaces provide an effective

  11. Extending BPM Environments of Your Choice with Performance Related Decision Support

    NASA Astrophysics Data System (ADS)

    Fritzsche, Mathias; Picht, Michael; Gilani, Wasif; Spence, Ivor; Brown, John; Kilpatrick, Peter

    What-if Simulations have been identified as one solution for business performance related decision support. Such support is especially useful in cases where it can be automatically generated out of Business Process Management (BPM) Environments from the existing business process models and performance parameters monitored from the executed business process instances. Currently, some of the available BPM Environments offer basic-level performance prediction capabilities. However, these functionalities are normally too limited to be generally useful for performance related decision support at business process level. In this paper, an approach is presented which allows the non-intrusive integration of sophisticated tooling for what-if simulations, analytic performance prediction tools, process optimizations or a combination of such solutions into already existing BPM environments. The approach abstracts from process modelling techniques which enable automatic decision support spanning processes across numerous BPM Environments. For instance, this enables end-to-end decision support for composite processes modelled with the Business Process Modelling Notation (BPMN) on top of existing Enterprise Resource Planning (ERP) processes modelled with proprietary languages.

  12. A high resolution cavity BPM for the CLIC Test Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chritin, N.; Schmickler, H.; Soby, L.

    2010-08-01

    In frame of the development of a high resolution BPM system for the CLIC Main Linac we present the design of a cavity BPM prototype. It consists of a waveguide loaded dipole mode resonator and a monopole mode reference cavity, both operating at 15 GHz, to be compatible with the bunch frequencies at the CLIC Test Facility. Requirements, design concept, numerical analysis, and practical considerations are discussed.

  13. Heart rate never lies: interventional cardiologist and Braude's quote revised

    PubMed Central

    Cook, Stéphane; Stauffer, Jean-Christophe; Goy, Jean-Jacques; Graf, Denis; Puricel, Serban; Frobert, Aurélien; Muller, Olivier; Togni, Mario; Arroyo, Diego

    2016-01-01

    Background Interventional cardiologists may be immune to stress, allowing them to perform complex percutaneous interventions under pressure. Objectives To assess heart rate (HR) variations as a surrogate marker of stress of interventional cardiologists during percutaneous cardiac procedures and in every-day life. Design This is a single-centre observational study including a total of six male interventional cardiologists performing coronary interventions and pacemaker implantations. Participants were asked to record their HR with the Apple Watch Device during procedures, every-day life and control activities such as outpatient consultations, sport, marital conflicts and sexual intercourse. Results Average daily HR was 88±17 bpm. During work days, HR increased significantly during procedures (90±17 bpm) compared with days outside the cathlab (87±17 bpm, p=0.02). The average HR was higher during a regular week working (88±16 bpm) compared with weekends off (84±18 bpm, p=0.002). Complex cardiac procedures were associated with higher HR up to 122 bpm. Peak HR were higher during physical exertion. Of note, participants complained of hypersexuality and mania after night shifts. Conclusions Work and especially percutaneous cardiac procedures increase HR independently of physical exertion suggesting that interventional cardiologists experience mental stress and emotions. PMID:26835145

  14. Heart rate never lies: interventional cardiologist and Braude's quote revised.

    PubMed

    Cook, Stéphane; Stauffer, Jean-Christophe; Goy, Jean-Jacques; Graf, Denis; Puricel, Serban; Frobert, Aurélien; Muller, Olivier; Togni, Mario; Arroyo, Diego

    2016-01-01

    Interventional cardiologists may be immune to stress, allowing them to perform complex percutaneous interventions under pressure. To assess heart rate (HR) variations as a surrogate marker of stress of interventional cardiologists during percutaneous cardiac procedures and in every-day life. This is a single-centre observational study including a total of six male interventional cardiologists performing coronary interventions and pacemaker implantations. Participants were asked to record their HR with the Apple Watch Device during procedures, every-day life and control activities such as outpatient consultations, sport, marital conflicts and sexual intercourse. Average daily HR was 88±17 bpm. During work days, HR increased significantly during procedures (90±17 bpm) compared with days outside the cathlab (87±17 bpm, p=0.02). The average HR was higher during a regular week working (88±16 bpm) compared with weekends off (84±18 bpm, p=0.002). Complex cardiac procedures were associated with higher HR up to 122 bpm. Peak HR were higher during physical exertion. Of note, participants complained of hypersexuality and mania after night shifts. Work and especially percutaneous cardiac procedures increase HR independently of physical exertion suggesting that interventional cardiologists experience mental stress and emotions.

  15. Global accuracy estimates of point and mean undulation differences obtained from gravity disturbances, gravity anomalies and potential coefficients

    NASA Technical Reports Server (NTRS)

    Jekeli, C.

    1979-01-01

    Through the method of truncation functions, the oceanic geoid undulation is divided into two constituents: an inner zone contribution expressed as an integral of surface gravity disturbances over a spherical cap; and an outer zone contribution derived from a finite set of potential harmonic coefficients. Global, average error estimates are formulated for undulation differences, thereby providing accuracies for a relative geoid. The error analysis focuses on the outer zone contribution for which the potential coefficient errors are modeled. The method of computing undulations based on gravity disturbance data for the inner zone is compared to the similar, conventional method which presupposes gravity anomaly data within this zone.

  16. Physical mechanism for flat-to-lenticular lens conversion in homogeneous liquid crystal cell with periodically undulated electrode.

    PubMed

    Na, Jun-Hee; Park, Seung Chul; Kim, Se-Um; Choi, Yoonseuk; Lee, Sin-Doo

    2012-01-16

    A convertible lenticular liquid crystal (LC) lens architecture is demonstrated using an index-matched planarization layer on a periodically undulated electrode for the homogeneous alignment of an LC. It is found that the in-plane component of the electric field by the undulated electrode plays a primary role in the flat-to-lens effect while the out-of-plane component contributes to the anchoring enhancement of the LC molecules in the surface layer. Our LC device having an index-matched planarization layer on the undulated electrode is capable of achieving the electrical tunability from the flat surface to the lenticular lens suitable for 2D/3D convertible displays.

  17. Development and operating experience of a 1.1-m-long superconducting undulator at the Advanced Photon Source

    NASA Astrophysics Data System (ADS)

    Ivanyushenkov, Y.; Harkay, K.; Borland, M.; Dejus, R.; Dooling, J.; Doose, C.; Emery, L.; Fuerst, J.; Gagliano, J.; Hasse, Q.; Kasa, M.; Kenesei, P.; Sajaev, V.; Schroeder, K.; Sereno, N.; Shastri, S.; Shiroyanagi, Y.; Skiadopoulos, D.; Smith, M.; Sun, X.; Trakhtenberg, E.; Xiao, A.; Zholents, A.; Gluskin, E.

    2017-10-01

    Development of superconducting undulators continues at the Advanced Photon Source (APS). Two years after successful installation and commissioning of the first relatively short superconducting undulator "SCU0" in Sector 6 of the APS storage ring, the second 1.1-m-long superconducting undulator "SCU1" was installed in Sector 1 of the APS. The device has been in user operation since its commissioning in May 2015. This paper describes the magnetic and cryogenic design of the SCU1 together with the results of stand-alone cold tests. The SCU1's magnetic and cryogenic performance as well as its operating experience in the APS storage ring are also presented.

  18. Undulator radiation from laser-plasma-accelerated electron beams

    NASA Astrophysics Data System (ADS)

    Shaw, B.; van Tilborg, J.; Gonsalves, A.; Nakamura, K.; Sokollik, T.; Shiraishi, S.; Mittal, R.; Esarey, E.; Schroeder, C.; Toth, C.; Leemans, W. P.

    2012-12-01

    Recent experiments coupled electron beams from the LOASIS TREX laser plasma accelerator (LPA) [1, 2, 3] to the Tapered Hybrid Undulator (THUNDER). Using the 1.5m, 66 period undulator, followed by an XUV spectrometer, spontaneous radiation was observed at photon energies extending to 100 eV. Previous experiments have reported visible [4] and soft-x-ray [5] radiation. The purpose of our experiments is to do highly precise, single shot diagnostics of the energy spread and emittance for each electron beam. We present recent results including measurements of electron beam transport through the undulator with and without the use of permanent magnetic quadrapoles, and measurements of XUV spectra up to 100 eV from LPA produced e-beams.

  19. Exercise Training Attenuates Sympathetic Activity and Improves Morphometry of Splenic Arterioles in Spontaneously Hipertensive Rats.

    PubMed

    Lemos, Marina de Paiva; Mota, Gustavo Ribeiro da; Marocolo, Moacir; Sordi, Carla Cristina de; Chriguer, Rosângela Soares; Barbosa Neto, Octávio

    2018-03-01

    Alterations in the structure of resistance vessels contribute to elevated systemic vascular resistance in hypertension and are linked to sympathetic hyperactivity and related lesions in target organs. To assess the effects of exercise training on hemodynamic and autonomic parameters, as well as splenic arteriolar damages in male Wistar Kyoto (WKY) and Spontaneously Hypertensive Rats (SHR). Normotensive sedentary (WKYS) and trained (WKYT) rats, and hypertensive sedentary (SHRS) and trained (SHRT) rats were included in this study. After 9 weeks of experimental protocol (swimming training or sedentary control), arterial pressure (AP) and heart rate (HR) were recorded in freely moving rats. We assessed the autonomic control of the heart by sympathetic and vagal autonomic blockade. Morphometric analyses of arterioles were performed in spleen tissues. The statistical significance level was set at p < 0.05. Resting bradycardia was observed in both trained groups (WKYT: 328.0 ± 7.3 bpm; SHRT: 337.0 ± 5.2 bpm) compared with their respective sedentary groups (WKYS: 353.2 ± 8.5 bpm; SHRS: 412.1 ± 10.4 bpm; p < 0.001). Exercise training attenuated mean AP only in SHRT (125.9 ± 6.2 mmHg) vs. SHRS (182.5 ± 4.2 mmHg, p < 0.001). The WKYT showed a higher vagal effect (∆HR: 79.0 ± 2.3 bpm) compared with WKYS (∆HR: 67.4 ± 1.7 bpm; p < 0.05). Chronic exercise decreased sympathetic effects on SHRT (∆HR: -62.8 ± 2.8 bpm) in comparison with SHRS (∆HR: -99.8 ± 9.2 bpm; p = 0.005). The wall thickness of splenic arterioles in SHR was reduced by training (332.1 ± 16.0 µm2 in SHRT vs. 502.7 ± 36.3 µm2 in SHRS; p < 0.05). Exercise training attenuates sympathetic activity and AP in SHR, which may be contributing to the morphological improvement of the splenic arterioles.

  20. Failed heart rate control with oral metoprolol prior to coronary CT angiography: effect of additional intravenous metoprolol on heart rate, image quality and radiation dose.

    PubMed

    Jiménez-Juan, Laura; Nguyen, Elsie T; Wintersperger, Bernd J; Moshonov, Hadas; Crean, Andrew M; Deva, Djeven P; Paul, Narinder S; Torres, Felipe S

    2013-01-01

    The purpose of this study was to evaluate the effect of intravenous (i.v.) metoprolol after a suboptimal heart rate (HR) response to oral metoprolol (75-150 mg) on HR control, image quality (IQ) and radiation dose during coronary CTA using 320-MDCT. Fifty-three consecutive patients who failed to achieve a target HR of < 60 bpm after an oral dose of metoprolol and required supplementary i.v. metoprolol (5-20 mg) prior to coronary CTA were evaluated. Patients with HR < 60 bpm during image acquisition were defined as responders (R) and those with HR ≥ 60 bpm as non-responders (NR). Two observers assessed IQ using a 3-point scale (1-2, diagnostic and 3, non-diagnostic). Effective dose (ED) was estimated using dose-length product and a 0.014 mSV/mGy.cm conversion factor. Baseline characteristics and HR on arrival were similar in the two groups. 58% of patients didn't achieve the target HR after receiving i.v. metoprolol (NR). R had a significantly higher HR reduction after oral (mean HR 63.9 ± 4.5 bpm vs. 69.6 ± 5.6 bpm) (p < 0.005) and i.v. (mean HR 55.4 ± 3.9 bpm vs. 67.4 ± 5.3 bpm) (p < 0.005) doses of metoprolol. Studies from NR showed a significantly higher ED in comparison to R (8.0 ± 2.9 vs. 6.1 ± 2.2 mSv) (p = 0.016) and a significantly higher proportion of non-diagnostic coronary segments (9.2 vs. 2.5%) (p < 0.001). 58% of patients who do not achieve a HR of <60 bpm prior to coronary CTA with oral fail to respond to additional i.v. metoprolol and have studies with higher radiation dose and worse image quality.

  1. Bailout intravenous esmolol for heart rate control in cardiac computed tomography angiography.

    PubMed

    Aguiar Rosa, Sílvia; Ramos, Ruben; Marques, Hugo; Santos, Rosana; Leal, Cecília; Casado, Helena; Saraiva, Márcia; Figueiredo, Luísa; Cruz Ferreira, Rui

    2016-12-01

    To evaluate the efficacy and safety of a heart rate (HR) reduction protocol using intravenous esmolol as bailout for failed oral metoprolol regimens in patients undergoing coronary computed tomography angiography (CCTA) with 64-slice multidetector computed tomography (64-MDCT). Patients who underwent cardiac 64-MDCT in a single institution between 2011 and 2014 were analyzed. Those with HR above 60 beats per minute (bpm) on presentation received oral metoprolol (50-200 mg) at least one hour before CCTA. Intravenous esmolol 1-2 mg/kg was administered as a bolus whenever HR remained over 65 bpm just before imaging. The primary efficacy endpoint was HR <65 bpm during CCTA. The primary safety endpoint was symptomatic hypotension or bradycardia up to hospital discharge. During the study period CCTA was performed in 947 cases. In 86% of these, oral metoprolol was the only medication required to successfully reduce HR <60 bpm. Esmolol was used in the remaining 130 patients (14%). For esmolol-treated patients mean baseline and acquisition HR were 74±14 bpm and 63±9 bpm, respectively (p<0.001). The target HR of <65 bpm was achieved in 82 of the 130 esmolol-treated patients (63%). Considering the whole population, esmolol use led to a significant increase in the primary efficacy endpoint from 86% to 95% (p<0.001). Esmolol also resulted in a statistically, but not clinically, significant reduction in systolic blood pressure (144±22 to 115±17 mmHg; p<0.001). The combined primary safety endpoint was only observed in two (1.5%) patients. Despite optimal use of oral beta-blockers, 14% of patients needed intravenous esmolol for HR control. The pre-medication combination of oral metoprolol and on-demand administration of intravenous esmolol was safe and effective and enabled 95% of patients to be imaged with HR below 65 bpm. Copyright © 2016 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  2. Heart rate at discharge and long-term prognosis following percutaneous coronary intervention in stable and acute coronary syndromes--results from the BASKET PROVE trial.

    PubMed

    Jensen, Magnus Thorsten; Kaiser, Christoph; Sandsten, Karl Erik; Alber, Hannes; Wanitschek, Maria; Iversen, Allan; Jensen, Jan Skov; Pedersen, Sune; Soerensen, Rikke; Rickli, Hans; Zurek, Marzena; Fahrni, Gregor; Bertel, Osmund; De Servi, Stefano; Erne, Paul; Pfisterer, Matthias; Galatius, Søren

    2013-10-09

    Elevated heart rate (HR) is associated with mortality in a number of heart diseases. We examined the long-term prognostic significance of HR at discharge in a contemporary population of patients with stable angina (SAP), non-ST-segment elevation acute coronary syndromes (NSTE-ACS), and ST-segment elevation myocardial infarction (STEMI) revascularized with percutaneous coronary intervention (PCI). Patients from the BASKET-PROVE trial, an 11-center randomized all-comers trial comparing bare-metal and drug-eluting stenting in large coronary vessels, were included. Discharge HR was determined from a resting ECG. Long-term outcomes (7 days to 2 years) were evaluated for all-cause mortality and cardiovascular death and non-fatal myocardial infarction. A total of 2029 patients with sinus rhythm were included, 722 (35.6%) SAP, 647 (31.9%) NSTE-ACS, and 660 (32.5%) STEMI. Elevated discharge HR was associated significantly with all-cause mortality: when compared to a reference of <60 beats per minute (bpm), the adjusted hazard ratios were (95% CI) 4.5 (1.5-13.5, p=0.006) for 60-69 bpm, 3.8 (1.2-11.9, p=0.022) for 70-79 bpm, 4.3 (1.2-15.6, p=0.025) for 80-89 bpm, and 16.9 (5.2-55.0, p<0.001) for >90 bpm. For cardiovascular death/myocardial infarction, a discharge HR >90 bpm was associated with a hazard ratio of 6.2 (2.5-15.5, p<0.001) compared to a HR <60 bpm. No interaction was found for disease presentation, diabetes or betablocker use. In patients revascularized with PCI for stable angina or acute coronary syndromes an elevated discharge HR was independently associated with poor prognosis. Conversely, a HR <60 bpm at discharge was associated with a good long-term prognosis irrespective of indication for PCI. © 2013.

  3. Utility of Time and Frequency Domain Parameters of Heart Rate Variability in the Context of Autonomic Disorders Characterized by Orthostatic Dysfunction.

    PubMed

    Baker, Jacquie; Racosta, Juan M; Balint, Brittany; Kimpinski, Kurt

    2018-03-01

    The clinical significance of heart rate variability in the context of autonomic dysfunction continues to be a matter of debate. A consensus is lacking on the best heart rate variability measures for clinical purposes. Therefore, the purpose of this study was to investigate the utility of heart rate variability parameters in healthy versus autonomic dysfunction. Healthy young (n = 134), healthy older (n = 32), and patients with mild (postural tachycardia syndrome; n = 25) and severe (neurogenic orthostatic hypotension; n = 34) autonomic dysfunction were included. Time and frequency parameters during baseline, head-up tilt (HUT), and heart rate response to deep breathing (HRDB) were compared. Cardiovagal time parameters were significantly reduced during HUT in healthy young and postural tachycardia syndrome (P < 0.001). Healthy young had significantly higher time parameters during baseline, HUT, and HRDB (P < 0.01). This was reflected by a significantly lower resting heart rate (HR) (61.4 ± 9.0 bpm vs. 76.8 ± 13.6 bpm; P < 0.001) and a smaller [INCREMENT]HR during HUT (32.8 ± 10.5 bpm vs. 44.4 ± 13.3 bpm; P < 0.001). Time parameters increased in young and postural tachycardia syndrome during HRDB, which was characterized by a nonsignificant difference in [INCREMENT]HR between both groups. Time parameters were significantly higher in healthy old versus neurogenic orthostatic hypotension at rest and during HRDB (P < 0.05). During HUT, only the SD of all normal RR intervals remained significantly higher. Heart rate changes corroborated these findings. Resting HR was significantly lower in healthy older (62.6 ± 11.0 bpm vs. 70.7 ± 12.4 bpm), and [INCREMENT]HR during HRDB was significantly higher (15.9 ± 9.2 bpm vs. 3.9 ± 4.2 bpm; P < 0.001). During HUT, [INCREMENT]HR showed no significant differences. Time domain parameters of heart rate variability have a greater utility than frequency parameters in clinical autonomic disorders.

  4. Central antioxidant therapy inhibits parasympathetic baroreflex control in conscious rats.

    PubMed

    Giusti, Marcelo Franchini; Sato, Monica Akemi; Cardoso, Leonardo Máximo; Braga, Valdir Andrade; Colombari, Eduardo

    2011-02-04

    Baroreceptor reflex is an important system for neural control of blood pressure. Recently, reactive oxygen species (ROS) have been shown to play an important role in neuronal activity of central areas related to blood pressure control. The aim of this study was to investigate the effects elicited by ascorbic acid (AAC) and N-acetylcysteine (NAC) injections into the 4thV on the parasympathetic component of the baroreflex. Male Wistar rats were implanted with a stainless steel guide cannula into the 4thV. One day prior to the experiments, the femoral artery and vein were cannulated for pulsatile arterial pressure, mean arterial pressure and heart rate measurements and drug administration, respectively. After baseline recordings, the baroreflex was tested with a pressor dose of phenylephrine (PHE, 3 μg/kg, i.v.) and a depressor dose of sodium nitroprusside (SNP, 30 μg/kg, i.v.) before (control) and 5, 15, 30 and 60 min after AAC or NAC into the 4thV. Control PHE injection induced baroreflex-mediated bradycardia (-93 ± 13 bpm, n=7). Interestingly, after AAC injection into the 4thV, PHE injection produced a transient tachycardia at 5 (40 ± 23 bpm), 15 (26 ± 22 bpm) and 30 min (59 ± 21 bpm). No changes were observed in baroreflex-mediated tachycardia evoked by SNP after AAC injection on 4thV (control: 151 ± 23bpm vs. 135 ± 18 bpm at 5 min after AAC, n=7). In the NAC treated group, PHE induced a reduction in reflex bradycardia at 5 min when compared to control (-11 ± 17 bpm vs. -83 ± 15 bpm, n=7). No changes were observed in baroreflex-mediated tachycardia evoked by SNP after NAC injection on 4thV. The antioxidants AAC and NAC may act in the central nervous system affecting the parasympathetic component of the cardiac baroreflex. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  5. Refurbishment of a used in-vacuum undulator from the National Synchrotron Light Source for the National Synchrotron Light Source-II ring

    DOE PAGES

    Tanabe, Toshiya; Bassan, Harmanpreet; Broadbent, Andrew; ...

    2017-08-01

    The National Synchrotron Light Source (NSLS) ceased operation in September 2014 and was succeeded by NSLS-II. There were four in-vacuum undulators (IVUs) in operation at NSLS. The most recently constructed IVU for NSLS was the mini-gap undulator (MGU-X25, to be renamed IVU18 for NSLS-II), which was constructed in 2006. This device was selected to be reused for the New York Structural Biology Consortium Microdiffraction beamline at NSLS-II. At the time of construction, IVU18 was a state-of-the-art undulator designed to be operated as a cryogenic permanent-magnet undulator. Due to the more stringent field quality and impedance requirements of the NSLS-II ring,more » the transition region was redesigned. The control system was also updated to NSLS-II specifications. As a result, this paper reports the details of the IVU18 refurbishment activities including additional magnetic measurement and tuning.« less

  6. Refurbishment of a used in-vacuum undulator from the National Synchrotron Light Source for the National Synchrotron Light Source-II ring

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tanabe, Toshiya; Bassan, Harmanpreet; Broadbent, Andrew

    The National Synchrotron Light Source (NSLS) ceased operation in September 2014 and was succeeded by NSLS-II. There were four in-vacuum undulators (IVUs) in operation at NSLS. The most recently constructed IVU for NSLS was the mini-gap undulator (MGU-X25, to be renamed IVU18 for NSLS-II), which was constructed in 2006. This device was selected to be reused for the New York Structural Biology Consortium Microdiffraction beamline at NSLS-II. At the time of construction, IVU18 was a state-of-the-art undulator designed to be operated as a cryogenic permanent-magnet undulator. Due to the more stringent field quality and impedance requirements of the NSLS-II ring,more » the transition region was redesigned. The control system was also updated to NSLS-II specifications. As a result, this paper reports the details of the IVU18 refurbishment activities including additional magnetic measurement and tuning.« less

  7. Association of Asymptomatic Bradycardia With Incident Cardiovascular Disease and Mortality: The Multi-Ethnic Study of Atherosclerosis (MESA).

    PubMed

    Dharod, Ajay; Soliman, Elsayed Z; Dawood, Farah; Chen, Haiying; Shea, Steven; Nazarian, Saman; Bertoni, Alain G

    2016-02-01

    Bradycardia has been associated with lower cardiovascular disease (CVD) risk in selected populations. There is a paucity of information available about heart rate (HR) less than 50 beats per minute (bpm) among middle-aged or older adults. To determine whether asymptomatic bradycardia was associated with a lower cardiovascular risk profile, less subclinical atherosclerosis, and decreased incident CVD and mortality. This retrospective analysis includes 6733 participants of the Multi-Ethnic Study of Atherosclerosis, which recruited men and women free of clinical cardiovascular disease ages 45 to 84 years from 2000 to 2002 and followed them over 10 years for incident CVD events and mortality. The HR was measured by baseline electrocardiogram. The analysis was performed in June 2014. The association between HR categories with CVD events and all-cause mortality were examined using Cox proportional hazards models adjusted for potential confounders and mediators. The 6733 participants had a mean (SD) age of 62 (10.2) years; 47% were male. The mean (SD) HR was 63 (9.5) bpm among the 5831 participants not taking an HR-modifying drug; 5.3% had an HR lower than 50 bpm. Preliminary results revealed significant interaction for HR categories according to use of HR-modifying drugs for mortality (P = .002); thus, all further analyses were stratified. An HR of less than 50 bpm was not associated with incident CVD in either subgroup (participants taking or not taking HR-modifying drugs). Among participants not taking HR-modifying drugs, the fully adjusted mortality risk was not different for an HR less than 50 bpm (hazard ratio, 0.71 [95% CI, 0.41-1.09]; P = .12) and increased among those with an HR greater than 80 bpm (hazard ratio, 1.49 [95% CI, 1.08-2.05]; P = .01) (reference HR, 60-69 bpm). Among the 902 participants taking HR-modifying drugs there was an elevated mortality risk associated with an HR less than 50 bpm (hazard ratio, 2.42 [95% CI, 1.39-4.20]; P = .002) and with an HR greater than 80 bpm (hazard ratio, 3.55 [95% CI, 1.65-7.65]; P = .001) (reference HR, 60-69 bpm). In a contemporary, community-based cohort, bradycardia was generally not associated with incident CVD or mortality except for a potential adverse association between bradycardia among those taking HR-modifying drugs.

  8. Algorithms to automate gap-dependent integral tuning for the 2.8-meter long horizontal field undulator with a dynamic force compensation mechanism

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xu, Joseph Z., E-mail: x@anl.gov; Vasserman, Isaac; Strelnikov, Nikita

    2016-07-27

    A 2.8-meter long horizontal field prototype undulator with a dynamic force compensation mechanism has been developed and tested at the Advanced Photon Source (APS) at Argonne National Laboratory (Argonne). The magnetic tuning of the undulator integrals has been automated and accomplished by applying magnetic shims. A detailed description of the algorithms and performance is reported.

  9. Earth's Magnetic Field Measurements for the LCLS Undulators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hacker, Kirsten

    2010-12-13

    Measurements of the earth's magnetic field at several locations at SLAC were conducted to determine the possible field error contribution from tuning the undulators in a location with a different magnetic field than that which will be found in the undulator hall. An average difference of 0.08 {+-} 0.04 Gauss has been measured between the downward earth's field components in the test facility and SLAC tunnel locations.

  10. BPM Breakdown Potential in the PEP-II B-factory Storage Ring Collider

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weathersby, Stephen; Novokhatski, Alexander; /SLAC

    2010-02-10

    High current B-Factory BPM designs incorporate a button type electrode which introduces a small gap between the button and the beam chamber. For achievable currents and bunch lengths, simulations indicate that electric potentials can be induced in this gap which are comparable to the breakdown voltage. This study characterizes beam induced voltages in the existing PEP-II storage ring collider BPM as a function of bunch length and beam current.

  11. Noise estimation of beam position monitors at RHIC

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shen, X.; Bai, M.; Lee, S. Y.

    2014-02-10

    Beam position monitors (BPM) are used to record the average orbits and transverse turn-by-turn displacements of the beam centroid motion. The Relativistic Hadron Ion Collider (RHIC) has 160 BPMs for each plane in each of the Blue and Yellow rings: 72 dual-plane BPMs in the insertion regions (IR) and 176 single-plane modules in the arcs. Each BPM is able to acquire 1024 or 4096 consecutive turn-by-turn beam positions. Inevitably, there are broadband noisy signals in the turn-by-turn data due to BPM electronics as well as other sources. A detailed study of the BPM noise performance is critical for reliable opticsmore » measurement and beam dynamics analysis based on turn-by-turn data.« less

  12. Cavity BPM system tests for the ILC energy spectrometer

    NASA Astrophysics Data System (ADS)

    Slater, M.; Adolphsen, C.; Arnold, R.; Boogert, S.; Boorman, G.; Gournaris, F.; Hildreth, M.; Hlaing, C.; Jackson, F.; Khainovski, O.; Kolomensky, Yu. G.; Lyapin, A.; Maiheu, B.; McCormick, D.; Miller, D. J.; Orimoto, T. J.; Szalata, Z.; Thomson, M.; Ward, D.; Wing, M.; Woods, M.

    2008-07-01

    The main physics programme of the International Linear Collider (ILC) requires a measurement of the beam energy at the interaction point with an accuracy of 10-4 or better. To achieve this goal a magnetic spectrometer using high resolution beam position monitors (BPMs) has been proposed. This paper reports on the cavity BPM system that was deployed to test this proposal. We demonstrate sub-micron resolution and micron level stability over 20 h for a 1 m long BPM triplet. We find micron-level stability over 1 h for 3 BPM stations distributed over a 30 m long baseline. The understanding of the behaviour and response of the BPMs gained from this work has allowed full spectrometer tests to be carried out.

  13. Statistical analysis of RHIC beam position monitors performance

    NASA Astrophysics Data System (ADS)

    Calaga, R.; Tomás, R.

    2004-04-01

    A detailed statistical analysis of beam position monitors (BPM) performance at RHIC is a critical factor in improving regular operations and future runs. Robust identification of malfunctioning BPMs plays an important role in any orbit or turn-by-turn analysis. Singular value decomposition and Fourier transform methods, which have evolved as powerful numerical techniques in signal processing, will aid in such identification from BPM data. This is the first attempt at RHIC to use a large set of data to statistically enhance the capability of these two techniques and determine BPM performance. A comparison from run 2003 data shows striking agreement between the two methods and hence can be used to improve BPM functioning at RHIC and possibly other accelerators.

  14. Fast pulsed excitation wiggler or undulator

    DOEpatents

    van Steenbergen, Arie

    1990-01-01

    A fast pulsed excitation, electromagnetic undulator or wiggler, employing geometrically alternating substacks of thin laminations of ferromagnetic material, together with a single turn current loop excitation of the composite assembly, of such shape and configuration that intense, spatially alternating, magnetic fields are generated; for use as a pulsed mode undulator or wiggler radiator, for use in a Free Electron Laser (FEL) type radiation source or, for use in an Inverse Free Electron Laser (IFEL) charged particle accelerator.

  15. Swimming Dynamics of the Lyme Disease Spirochete

    NASA Astrophysics Data System (ADS)

    Vig, Dhruv K.; Wolgemuth, Charles W.

    2012-11-01

    The Lyme disease spirochete, Borrelia burgdorferi, swims by undulating its cell body in the form of a traveling flat wave, a process driven by rotating internal flagella. We study B. burgdorferi’s swimming by treating the cell body and flagella as linearly elastic filaments. The dynamics of the cell are then determined from the balance between elastic and resistive forces and moments. We find that planar, traveling waves only exist when the flagella are effectively anchored at both ends of the bacterium and that these traveling flat waves rotate as they undulate. The model predicts how the undulation frequency is related to the torque from the flagellar motors and how the stiffness of the cell body and flagella affect the undulations and morphology.

  16. The Tapered Hybrid Undulator (THUNDER) of the visible free-electron laser oscillator experiment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robinson, K.E.; Quimby, D.C.; Slater, J.M.

    A 5 m tapered hybrid undulator (THUNDER) has been designed and built as part of the Boeing Aerospace Company and Spectra Technology, Inc. visible free-electron laser (FEL) oscillator experiment. The performance goals required of an undulator for a visible oscillator with large extraction are ambitious. They require the establishment of stringent magnetic field quality tolerances which impact design and fabrication techniques. The performance goals of THUNDER are presented. The tolerances resulting from the FEL interaction are contrasted and compared to those of a synchrotron radiation source. The design, fabrication, and field measurements are discussed. The performance of THUNDER serves asmore » a benchmark for future wiggler/undulator design for advanced FEL's and synchrotron radiation sources.« less

  17. Swimming dynamics of the lyme disease spirochete.

    PubMed

    Vig, Dhruv K; Wolgemuth, Charles W

    2012-11-21

    The Lyme disease spirochete, Borrelia burgdorferi, swims by undulating its cell body in the form of a traveling flat wave, a process driven by rotating internal flagella. We study B. burgdorferi's swimming by treating the cell body and flagella as linearly elastic filaments. The dynamics of the cell are then determined from the balance between elastic and resistive forces and moments. We find that planar, traveling waves only exist when the flagella are effectively anchored at both ends of the bacterium and that these traveling flat waves rotate as they undulate. The model predicts how the undulation frequency is related to the torque from the flagellar motors and how the stiffness of the cell body and flagella affect the undulations and morphology.

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    RAKOWKSY,G.; ASPENLEITER,J.; SOLOMON,L.

    The Visible-Infrared SASE Amplifier (VISA) undulator is an in-vacuum, 4-meter long, 1.8 cm period, pure-permanent magnet device, with a novel, strong focusing, permanent magnet FODO array included within the fixed, 6 mm undulator gap. The undulator magnet is constructed of 99-cm long segments, joined into a continuous structure. To attain maximum SASE gain requites establishing overlap of electron and photon beams to within 50 microns rms. This imposes challenging tolerances on mechanical fabrication and magnetic field quality, and necessitates use of laser straightness interferometry for calibration and alignment of the magnetic axes of the undulator segments. This paper describes themore » computerized magnet sorting, pulsed-wire magnetic measurements, trajectory shimming and magnetic axis calibration performed to meet this goal.« less

  19. Optimal reconstruction interval in dual source CT coronary angiography: a single-center experience in 285 patients

    PubMed Central

    Akgöz, Ayça; Akata, Deniz; Hazırolan, Tuncay; Karçaaltıncaba, Muşturay

    2014-01-01

    PURPOSE We aimed to evaluate the visibility of coronary arteries and bypass-grafts in patients who underwent dual source computed tomography (DSCT) angiography without heart rate (HR) control and to determine optimal intervals for image reconstruction. MATERIALS AND METHODS A total of 285 consecutive cases who underwent coronary (n=255) and bypass-graft (n=30) DSCT angiography at our institution were identified retrospectively. Patients with atrial fibrillation were excluded. Ten datasets in 10% increments were reconstructed in all patients. On each dataset, the visibility of coronary arteries was evaluated using the 15-segment American Heart Association classification by two radiologists in consensus. RESULTS Mean HR was 76±16.3 bpm, (range, 46–127 bpm). All coronary segments could be visualized in 277 patients (97.19%). On a segment-basis, 4265 of 4275 (99.77%) coronary artery segments were visible. All segments of 56 bypass-grafts in 30 patients were visible (100%). Total mean segment visibility scores of all coronary arteries were highest at 70%, 40%, and 30% intervals for all HRs. The optimal reconstruction intervals to visualize the segments of all three coronary arteries in descending order were 70%, 60%, 80%, and 30% intervals in patients with a mean HR <70 bpm; 40%, 70%, and 30% intervals in patients with a mean HR 70–100 bpm; and 40%, 50%, and 30% in patients with a mean HR >100 bpm. CONCLUSION Without beta-blocker administration, DSCT coronary angiography offers excellent visibility of vascular segments using both end-systolic and mid-late diastolic reconstructions at HRs up to 100 bpm, and only end-systolic reconstructions at HRs over 100 bpm. PMID:24834490

  20. Prognostic impact of heart rate in elderly with systolic heart failure and concomitant atrial fibrillation.

    PubMed

    Barywani, Salim; Petzold, Max

    2017-08-01

    The present study aimed to investigate the impact of resting heart rate (HR) on 5-year all-cause mortality in patients ≥80 years with heart failure (HF) with reduced ejection fraction (HFrEF) and concomitant atrial fibrillation (AF) after optimal up-titration of beta-blockers (BBs). Patients (n = 185) aged ≥80 years with HF and left ventricular ejection fraction ≤40% were included between January 2000 and January 2008 from two university hospitals, Sahlgrenska and Östra and retrospectively studied from January 2 to May 30, 2013. Up-titrations of guideline recommended medications were performed at HF outpatient clinics. Of whole study population, 54% (n= 100) had AF. After optimal up-titration of BBs and angiotensin converting enzyme inhibitors (ACEIs)/angiotensin receptor blockers (ARBs), mean HR in patients with AF was 73 ± 15 beats/minute (bpm), 36% had resting HR ≤65 bpm. Five-year all-cause mortality among patients with AF was significantly lower in patients with HR ≤65 bpm (63%) compared to HR >65 (80%). Cox proportional-hazard regression analysis adjusted for clinically important baseline variables and doses of ACEIs/ARBs and BBs demonstrated resting HR ≤65 bpm as an independent predictor of improved survival compared to resting HR >65 bpm (HR 0.3, 95%CI 0.1-0.7, P 0.005). In octogenarians with HFrEF and concomitant AF, lowering resting HR to levels as low as HR ≤65 bpm was still associated with improved survival from all-cause mortality. Our data indicate that mortality in AF became comparable to SR when patients were on maximally up-titrated beta-blocker doses with HR as low as 75 bpm.

  1. Surgical management of bronchopulmonary malformations.

    PubMed

    Wagenaar, Amy E; Tashiro, Jun; Hirzel, Alicia; Rodriguez, Luis I; Perez, Eduardo A; Hogan, Anthony R; Neville, Holly L; Sola, Juan E

    2015-10-01

    Bronchopulmonary malformations (BPM) are rare conditions, which typically arise below the carina and can result in significant morbidity (infection and/or hemorrhage) and mortality (respiratory failure). All children with BPM surgically treated from 2001-2014 at a tertiary care children's hospital were identified. Patient demographics, surgical indications, procedure type, estimated blood loss, pathology, perioperative complications, length of stay, and outcomes were analyzed. A total of 41 BPM patients underwent surgery with 98% overall survival (one abdominal BPM expired) but 100% for thoracic lesions. Resections were performed thoracoscopically (37%), thoracoscopy converted to open (22%), and via thoracotomy (37%). Poor visualization (67%) or inability to tolerate single lung ventilation (33%) led to conversions. No conversions resulted from hemorrhage or received blood transfusions. Patients with prenatally diagnosed BPM were more likely to undergo thoracoscopic surgery (odds ratio [OR], 18.2) versus nonprenatally diagnosed, P = 0.002. Open/converted patients had longer chest tube days (6.2) versus thoracoscopic (2.9), P = 0.048. Additionally, respiratory distress was a more common indication in patients aged <4 mo (OR, 28.0) versus ≥4 mo and <6 kg (OR, 40.5) versus ≥6 kg, P < 0.001. Open resections were more common in patients aged <4 mo (OR, 26.3) versus ≥4 mo, P = 0.002. Operative time was shorter and estimated blood loss (mL/kg) was greater for <6 versus ≥6 kg, P < 0.05. BPM resections have high overall survival. Chest tube days are shorter among thoracoscopic patients, but conversion to thoracotomy can avoid hemorrhage and need for transfusion. Size and respiratory distress limit use of thoracoscopy in young infants with BPM. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. Dependency of exercise-induced T-wave alternans predictive power for the occurrence of ventricular arrhythmias from heart rate.

    PubMed

    Burattini, Laura; Man, Sumche; Fioretti, Sandro; Di Nardo, Francesco; Swenne, Cees A

    2015-07-01

    T-wave alternans (TWA) is a noninvasive index of risk for the occurrence of ventricular arrhythmias. It is known that TWA amplitude (TWAA) increases with heart rate (HR) but how the TWA predictive power varies with HR remains unknown. Thus, the aim of this study was to evaluate the dependency of exercise-induced TWA predictive power for the occurrence of ventricular arrhythmias from HR. TWA was identified using our HR adaptive match filter in exercise ECGs from 248 patients with implanted cardiac defibrillator (ICD), of which 72 developed ventricular tachycardia and/or fibrillation during the 4 year follow-up (ICD_Cases) and 176 did not (ICD_Controls). TWA predictive power was evaluated at HRs from 80 to 120 bpm by computing the area under the receiver operating characteristic curve (AUC) obtained using the maximum TWAA (maxTWAA) and the TWAA ratio (TWAAratio; i.e., the ratio between TWAA at a specific HR and at 80 bpm). TWAA increased with HR. At 80 bpm maxTWAA was lower than at 120 bpm in both ICD_Cases (22 μV vs 41 μV; P < 10(-2) ) and ICD_ Controls (16 μV vs 36 μV; P < 10(-4) ). However, only at 80 bpm ICD_Cases showed significantly higher maxTWAA than ICD_Controls (AUC = 0.6486; P = 0.0080). TWAAratio was higher in ICD_Controls than ICD_Cases for all HR but 120 bpm, and its predictive power was maximum at 115 bpm (AUC = 0.6914; P < 0.05). Exercise-induced TWA predictive power for the occurrence of ventricular arrhythmias, quantified using both maxTWAA and TWAAratio, was higher at low rather than at high HR. © 2014 Wiley Periodicals, Inc.

  3. Reliability and Validity the Brief Problem Monitor, an Abbreviated Form of the Child Behavior Checklist

    PubMed Central

    Piper, Brian J.; Gray, Hilary M.; Raber, Jacob; Birkett, Melissa A.

    2014-01-01

    Aim The parent form of the 113 item Child Behavior Checklist (CBCL) is widely utilized by child psychiatrists and psychologists. This report examines the reliability and validity of a recently developed abbreviated version of the CBCL, the Brief Problem Monitor (BPM). Methods Caregivers (N=567) completed the CBCL online and the 19 BPM items were examined separately. Results Internal consistency of the BPM was high (Cronbach’s alpha=0.91) and satisfactory for the Internalizing (0.78), Externalizing (0.86), and Attention (0.87) scales. High correlations between the CBCL and BPM were identified for the total score (r=0.95) as well as the Internalizing (0.86), Externalizing (0.93), and Attention (0.97) scales. The BPM and scales were sensitive and identified significantly higher behavioral and emotional problems among children whose caregiver reported a psychiatric diagnosis of Attention Deficit Hyperactivity Disorder, bipolar, depression, anxiety, developmental disabilities, or Autism Spectrum Disorders relative to a comparison group that had not been diagnosed with these disorders. BPM ratings also differed by the socioeconomic status and education of the caregiver. Mothers with higher annual incomes rated their children as having 38.8% fewer total problems (Cohen’s d=0.62) as well as 42.8% lower Internalizing (d=0.53), 44.1% less Externalizing (d=0.62), and 30.9% decreased Attention (d=0.39). A similar pattern was evident for maternal education (d=0.30 to 0.65). Conclusion Overall, these findings provide strong psychometric support for the BPM although the differences based on the characteristics of the parent indicates that additional information from other sources (e.g., teachers) should be obtained to complement parental reports. PMID:24735087

  4. Heart rate in patients with reduced ejection fraction: relationship between single time point measurement and mean heart rate on prolonged implantable cardioverter defibrillator monitoring.

    PubMed

    Habal, Marlena V; Nanthakumar, Kumaraswamy; Austin, Peter C; Freitas, Cassandra; Labos, Christopher; Lee, Douglas S

    2018-01-31

    Heart rate (HR) is a prognostic marker that is increasingly used as a therapeutic target in patients with cardiovascular disease. The association between resting and mean HR remains unclear. We therefore set out to determine the relationship between resting HR on the electrocardiogram (ECG) obtained at a single time point, and mean HR on implantable cardioverter defibrillator (ICD) interrogation amongst patients with a reduced left ventricular ejection fraction (LVEF). Prospective ICD data were obtained from 54 patients with LVEF < 40%. Mean HR determined using the ICD HR histograms was compared with resting HR measured on the ECG performed in the clinic. Average resting and ICD mean HRs were 67.9 ± 10.1 and 67.8 ± 9.6 bpm respectively. There was good correlation in the overall cohort (r = 0.79), in those with resting ECG HRs ≤ 70 bpm (r = 0.62), and amongst the 27 patients on intermediate-to-high dose beta-blockers (r = 0.91). However, Bland-Altman analysis demonstrated wide limits of agreement in the overall cohort (- 12.5, 12.7 bpm), at resting HRs ≤ 70 bpm (- 12.7, 9.8 bpm), and on intermediate-to-high dose beta-blockers (- 8.9, 7.4 bpm). Moreover, resting HR did not predict the 10-bpm interval where the most time was spent. While resting HR correlated with mean HR in patients with reduced LVEF, and in important subgroups, the limits of agreement were unacceptably wide raising concern over the use of single time point resting HR as a therapeutic target.

  5. Comparing the Effects of Rest and Massage on Return to Homeostasis Following Submaximal Aerobic Exercise: a Case Study.

    PubMed

    Resnick, Portia B

    2016-03-01

    Postexercise massage can be used to help promote recovery from exercise on the cellular level, as well as systemically by increasing parasympathetic activity. No studies to date have been done to assess the effects of massage on postexercise metabolic changes, including excess postexercise oxygen consumption (EPOC). The purpose of this study was to compare the effects of massage recovery and resting recovery on a subject's heart rate variability and selected metabolic effects following a submaximal treadmill exercise session. One healthy 24-year-old female subject performed 30 minutes of submaximal treadmill exercise prior to resting or massage recovery sessions. Metabolic data were collected throughout the exercise sessions and at three 10 minute intervals postexercise. Heart rate variability was evaluated for 10 minutes after each of two 30-minute recovery sessions, either resting or massage. Heart rate returned to below resting levels (73 bpm) with 30 and 60 minutes of massage recovery (72 bpm and 63 bpm, respectively) compared to 30 and 60 minutes of resting recovery (77 bpm and 74 bpm, respectively). Heart rate variability data showed a more immediate shift to the parasympathetic state following 30 minutes of massage (1.152 LF/HF ratio) versus the 30-minute resting recovery (6.91 LF/HF ratio). It took 60 minutes of resting recovery to reach similar heart rate variability levels (1.216 LF/HF) found after 30 minutes of massage. Ventilations after 30 minutes of massage recovery averaged 7.1 bpm compared to 17.9 bpm after 30 minutes of resting recovery. No differences in EPOC were observed through either the resting or massage recovery based on the metabolic data collected. Massage was used to help the subject shift into parasympathetic activity more quickly than rest alone following a submaximal exercise session.

  6. Renal sympathetic denervation improves rate control in patients with symptomatic persistent atrial fibrillation and hypertension.

    PubMed

    Qiu, Min; Shan, Qijun; Chen, Chun; Geng, Jie; Guo, Jiqun; Zhou, Xiujuan; Qian, Weichong; Tang, Lijun; Yin, Yuehui

    2016-02-01

    The aim of this study was to investigate whether renal sympathetic denervation (RSD) improves ventricular heart rate (HR) control in patients with persistent atrial fibrillation (AF). Twenty-one patients (aged 57.5 ± 10.2 years, 76.2% male) with persistent AF and hypertension underwent RSD and completed 7-days follow-up evaluations, including 24-hour Holter monitoring (Holter), blood pressure (BP), 24-hour ambulatory BP monitoring (ABPM). Patients were grouped into tertiles of average HR at baseline Holter recording for evaluation of RSD effects on atrioventricular (AV) node (group 1: HR ≧ 90 bpm; group 2: 80 bpm ≦ HR < 90 bpm; group 3: HR < 80 bpm). All patients successfully underwent RSD without any complications. The clinical and procedural characteristics were similar in all groups of patients. No significant changes in BP were observed in the three groups before and after RSD. Compared with baseline, the average HR (Holter) of patients in group 1, 2 and 3 had a reduction of 22.6 ± 13.2 bpm (83.3 ± 4.9 vs 106.0 ± 14.6, P = 0.004), 9.7 ± 7.8 bpm (75.7 ± 7.6 vs 85.4 ± 3.7, P = 0.017) and 2.3 ± 2.9 bpm (71.4 ± 4.0 vs 73.7 ± 4.7, P = 0.089) at 7 days after RSD, respectively. RSD could improve ventricular HR control in patients with persistent AF. RSD slowed AV node conduction in baseline HR-dependent manner. RSD may become an alternative non-pharmaceutical tool for rate control in patients with persistent AF.

  7. Behavioral correlates of heart rates of free-living Greater White-fronted Geese

    USGS Publications Warehouse

    Ely, Craig R.; Ward, D.H.; Bollinger, K.S.

    1999-01-01

    We simultaneously monitored the heart rate and behavior of nine free-living Greater White-fronted Geese (Anser albifrons) on their wintering grounds in northern California. Heart rates of wild geese were monitored via abdominally-implanted radio transmitters with electrodes that received electrical impulses of the heart and emitted a radio signal with each ventricular contraction. Post-operative birds appeared to behave normally, readily rejoining flocks and flying up to 15 km daily from night-time roost sites to feed in surrounding agricultural fields. Heart rates varied significantly among individuals and among behaviors, and ranged from less than 100 beats per minute (BPM) during resting, to over 400 BPM during flight. Heart rates varied from 80 to 140 BPM during non-strenuous activities such as walking, feeding, and maintenance activities, to about 180 BPM when birds became alert, and over 400 BPM when birds were startled, even if they did not take flight. Postflight heart rate recovery time averaged < 10 sec. During agonistic encounters, heart rate exceeded 400 BPM; heart rates during social interactions were not predictable solely from postures, as heart rates were context-dependent, and were highest in initial encounters among individuals. Instantaneous measures of physiological parameters, such as heart rate, are often better indicators of the degree of response to external stimuli than visual observations and can be used to improve estimates of energy expenditure based solely on activity data.

  8. Conditioning of BPM pickup signals for operations of the Duke storage ring with a wide range of single-bunch current

    NASA Astrophysics Data System (ADS)

    Xu, Wei; Li, Jing-Yi; Huang, Sen-Lin; Z. Wu, W.; Hao, H.; P., Wang; K. Wu, Y.

    2014-10-01

    The Duke storage ring is a dedicated driver for the storage ring based oscillator free-electron lasers (FELs), and the High Intensity Gamma-ray Source (HIGS). It is operated with a beam current ranging from about 1 mA to 100 mA per bunch for various operations and accelerator physics studies. High performance operations of the FEL and γ-ray source require a stable electron beam orbit, which has been realized by the global orbit feedback system. As a critical part of the orbit feedback system, the electron beam position monitors (BPMs) are required to be able to precisely measure the electron beam orbit in a wide range of the single-bunch current. However, the high peak voltage of the BPM pickups associated with high single-bunch current degrades the performance of the BPM electronics, and can potentially damage the BPM electronics. A signal conditioning method using low pass filters is developed to reduce the peak voltage to protect the BPM electronics, and to make the BPMs capable of working with a wide range of single-bunch current. Simulations and electron beam based tests are performed. The results show that the Duke storage ring BPM system is capable of providing precise orbit measurements to ensure highly stable FEL and HIGS operations.

  9. A full vectorial generalized discontinuous Galerkin beam propagation method (GDG-BPM) for nonsmooth electromagnetic fields in waveguides

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fan Kai; Cai Wei; Ji Xia

    2008-07-20

    In this paper, we propose a new full vectorial generalized discontinuous Galerkin beam propagation method (GDG-BPM) to accurately handle the discontinuities in electromagnetic fields associated with wave propagations in inhomogeneous optical waveguides. The numerical method is a combination of the traditional beam propagation method (BPM) with a newly developed generalized discontinuous Galerkin (GDG) method [K. Fan, W. Cai, X. Ji, A generalized discontinuous Galerkin method (GDG) for Schroedinger equations with nonsmooth solutions, J. Comput. Phys. 227 (2008) 2387-2410]. The GDG method is based on a reformulation, using distributional variables to account for solution jumps across material interfaces, of Schroedinger equationsmore » resulting from paraxial approximations of vector Helmholtz equations. Four versions of the GDG-BPM are obtained for either the electric or magnetic field components. Modeling of wave propagations in various optical fibers using the full vectorial GDG-BPM is included. Numerical results validate the high order accuracy and the flexibility of the method for various types of interface jump conditions.« less

  10. Detection of Instrumental Drifts in the PEP II LER BPM System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wittmer, W.; Fisher, A.S.; Martin, D.J.

    2007-11-07

    During the last PEP-II run a major goal was to bring the Low-Energy Ring optics as close as possible to the design. A large number of BPMs exhibited sudden artificial jumps that interfered with this effort. The source of the majority of these jumps had been traced to the filter-isolator boxes (FIBs) near the BPM buttons. A systematic approach to find and repair the failing units had been developed and implemented. Despite this effort, the instrumental orbit jumps never completely disappeared. To trace the source of this behavior a test setup, using a spare Bergoz MX-BPM processor (kindly provided bymore » SPEAR III at SSRL), was connected in parallel to various PEP-II BPM processors. In the course of these measurements a slow instrumental orbit drift was found which was clearly not induced by a moving positron beam. Based on the size of the system and the limited time before PEP-II closes in Oct.2008, an accelerator improvement project was initiated to install BERGOZ BPM-MX processors close to all sextupoles.« less

  11. A Reverse-Translational Approach to Bipolar Disorder: Rodent and human studies in the Behavioral Pattern Monitor

    PubMed Central

    Young, Jared W.; Minassian, Arpi; Paulus, Martin P.; Geyer, Mark A.; Perry, William

    2007-01-01

    Mania is the defining feature of Bipolar Disorder (BD). There has been limited progress in understanding the neurobiological underpinnings of BD mania and developing novel therapeutics, in part due to a paucity of relevant animal models with translational potential. Hyperactivity is a cardinal symptom of mania, traditionally measured in humans using observer-rated scales. Multivariate assessment of unconditioned locomotor behavior using the rat Behavioral Pattern Monitor (BPM) developed in our laboratory has shown that hyperactivity includes complex multifaceted behaviors. The BPM has been used to demonstrate differential effects of drugs on locomotor activity and exploratory behavior in rats. Studies of genetically engineered mice in a mouse BPM have confirmed its utility as a cross-species tool. In a “reverse-translational” approach to this work, we developed the human BPM to characterize motor activity in BD patients. Increased activity, object interactions, and altered locomotor patterns provide multidimensional phenotypes to model in the rodent BPM. This unique approach to modeling BD provides an opportunity to identify the neurobiology underlying BD mania and test novel antimanic agents. PMID:17706782

  12. Top-up operation at Pohang Light Source-II

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hwang, I.; Huang, J. Y.; Kim, M.

    2014-05-15

    After three years of upgrading work, PLS-II (S. Shin, Commissioning of the PLS-II, JINST, January 2013) is now successfully operating. The top-up operation of the 3 GeV linear accelerator had to be delayed because of some challenges encountered, and PLS-II was run in decay mode at the beginning in March 2012. The main difficulties encountered in the top-up operation of PLS-II are different levels between the linear accelerator and the storage ring, the 14 narrow gap in-vacuum undulators in operation, and the full energy injection by 3 GeV linear accelerator. Large vertical emittance and energy jitter of the linac weremore » the major obstacles that called for careful control of injected beam to reduce beam loss in the storage ring during injection. The following measures were taken to resolve these problems: (1) The high resolution Libera BPM (see http://www.i-tech.si ) was implemented to measure the beam trajectory and energy. (2) Three slit systems were installed to filter the beam edge. (3) De-Qing circuit was applied to the modulator system to improve the energy stability of injected beam. As a result, the radiation by beam loss during injection is reduced drastically, and the top-up mode has been successfully operating since 19th March 2013. In this paper, we describe the experimental results of the PLS-II top-up operation and the improvement plan.« less

  13. Three-dimensional, time-dependent simulation of free-electron lasers with planar, helical, and elliptical undulators

    NASA Astrophysics Data System (ADS)

    Freund, H. P.; van der Slot, P. J. M.; Grimminck, D. L. A. G.; Setija, I. D.; Falgari, P.

    2017-02-01

    Free-electron lasers (FELs) have been built ranging in wavelength from long-wavelength oscillators using partial wave guiding through ultraviolet through hard x-ray that are either seeded or start from noise. In addition, FELs that produce different polarizations of the output radiation ranging from linear through elliptic to circular polarization are currently under study. In this paper, we develop a three-dimensional, time-dependent formulation that is capable of modeling this large variety of FEL configurations including different polarizations. We employ a modal expansion for the optical field, i.e., a Gaussian expansion with variable polarization for free-space propagation. This formulation uses the full Newton-Lorentz force equations to track the particles through the optical and magnetostatic fields. As a result, arbitrary three-dimensional representations for different undulator configurations are implemented, including planar, helical, and elliptical undulators. In particular, we present an analytic model of an APPLE-II undulator to treat arbitrary elliptical polarizations, which is used to treat general elliptical polarizations. To model oscillator configurations, and allow propagation of the optical field outside the undulator and interact with optical elements, we link the FEL simulation with the optical propagation code OPC. We present simulations using the APPLE-II undulator model to produce elliptically polarized output radiation, and present a detailed comparison with recent experiments using a tapered undulator configuration at the Linac Coherent Light Source. Validation of the nonlinear formation is also shown by comparison with experimental results obtained in the Sorgente Pulsata Auto-amplificata di Radiazione Coerente SASE FEL experiment at ENEA Frascati, a seeded tapered amplifier experiment at Brookhaven National Laboratory, and the 10 kW upgrade oscillator experiment at the Thomas Jefferson National Accelerator Facility.

  14. Cavity BPM System Tests for the ILC Spectrometer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Slater, M.

    2007-12-21

    The main physics program of the International Linear Collider (ILC) requires a measurement of the beam energy at the interaction point with an accuracy of 10{sup -4} or better. To achieve this goal a magnetic spectrometer using high resolution beam position monitors (BPMs) has been proposed. This paper reports on the cavity BPM system that was deployed to test this proposal. We demonstrate sub-micron resolution and micron level stability over 20 hours for a 1 m long BPM triplet. We find micron-level stability over 1 hour for 3 BPM stations distributed over a 30 m long baseline. The understanding ofmore » the behavior and response of the BPMs gained from this work has allowed full spectrometer tests to be carried out.« less

  15. RHIC BPM SYSTEM MODIFICATIONS AND PERFORMANCE.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    SATOGATA, T.; CALAGA, R.; CAMERON, P.

    2005-05-16

    The RHIC beam position monitor (BPM) system provides independent average orbit and turn-by-turn (TBT) position measurements. In each ring, there are 162 measurement locations per plane (horizontal and vertical) for a total of 648 BPM planes in the RHIC machine. During 2003 and 2004 shutdowns, BPM processing electronics were moved from the RHIC tunnel to controls alcoves to reduce radiation impact, and the analog signal paths of several dozen modules were modified to eliminate gain-switching relays and improve signal stability. This paper presents results of improved system performance, including stability for interaction region beam-based alignment efforts. We also summarize performancemore » of recently-added DSP profile scan capability, and improved million-turn TBT acquisition channels for 10 Hz triplet vibration, nonlinear dynamics, and echo studies.« less

  16. Service Contract Compliance Management in Business Process Management

    NASA Astrophysics Data System (ADS)

    El Kharbili, Marwane; Pulvermueller, Elke

    Compliance management is a critical concern for corporations, required to respect contracts. This concern is particularly relevant in the context of business process management (BPM) as this paradigm is getting adopted more widely for-designing and building IT systems. Enforcing contractual compliance needs to be modeled at different levels of a BPM framework, which also includes the service layer. In this paper, we discuss requirements and methods for modeling contractual compliance for an SOA-supported BPM. We also show how business rule management integrated into an industry BPM tool allows modeling and processing functional and non-functional-property constraints which may be extracted from business process contracts. This work proposes a framework that responds to the requirements identified and proposes an architecture implementing it. Our approach is also illustrated by an example.

  17. Beamline front end for in-vacuum short period undulator at the photon factory storage ring

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miyauchi, Hiroshi, E-mail: hiroshi.miyauchi@kek.jp; Department of Accelerator Science, School of High Energy Accelerator Science, SOKENDAI; Tahara, Toshihiro, E-mail: ttahara@post.kek.jp

    The straight-section upgrade project of the Photon Factory created four new short straight sections capable of housing in-vacuum short period undulators. The first to fourth short period undulators SGU#17, SGU#03, SGU#01 and SGU#15 were installed at the 2.5-GeV Photon Factory storage ring in 2005, 2006, 2009 and 2013, respectively. The beamline front end for SGU#15 is described in this paper.

  18. PEP as a synchrotron radiation source (invited)

    NASA Astrophysics Data System (ADS)

    Bienenstock, A.; Brown, G.; Wiedemann, H.; Winick, H.

    1989-07-01

    The 16-GeV storage ring PEP has characteristics which enable it to operate in modes with very low emittance and to accommodate very long undulators, producing synchrotron radiation at x-ray wavelengths with extremely high brightness and coherent power. Two beamlines, each illuminated by a 2-m long, 77-mm period undulator magnet, are now operational and others are planned. In parasitic operation during colliding-beam runs at 14.5 GeV, these beamlines provide photons above 10 keV with a peak brightness of about 1016 photons/(s mm2 mrad2 ) within a 0.1% bandwidth. In low-emittance tests at 7.1 GeV, horizontal emittances of about 5 nm rad were measured, which is about the same as that planned for the new third-generation x-ray sources. With a current of 15 mA at 7.1 GeV, the present undulators deliver photon beams from 2.7 to 14 keV with a peak brightness of about 1017 . Higher performance levels are expected with the implementation of longer undulators and shorter period undulators. In the longer term, because of its large circumference and long straight sections, PEP could be further developed to achieve even higher performance levels with an emittance below 1 nm rad, very long undulators and picosecond bunches, resulting in one to two orders of magnitude higher brightness and coherent power.

  19. Sideband instability analysis based on a one-dimensional high-gain free electron laser model

    DOE PAGES

    Tsai, Cheng-Ying; Wu, Juhao; Yang, Chuan; ...

    2017-12-18

    When an untapered high-gain free electron laser (FEL) reaches saturation, the exponential growth ceases and the radiation power starts to oscillate about an equilibrium. The FEL radiation power or efficiency can be increased by undulator tapering. For a high-gain tapered FEL, although the power is enhanced after the first saturation, it is known that there is a so-called second saturation where the FEL power growth stops even with a tapered undulator system. The sideband instability is one of the primary reasons leading to this second saturation. In this paper, we provide a quantitative analysis on how the gradient of undulatormore » tapering can mitigate the sideband growth. The study is carried out semianalytically and compared with one-dimensional numerical simulations. The physical parameters are taken from Linac Coherent Light Source-like electron bunch and undulator systems. The sideband field gain and the evolution of the radiation spectra for different gradients of undulator tapering are examined. It is found that a strong undulator tapering (~10 % ) provides effective suppression of the sideband instability in the postsaturation regime.« less

  20. Sideband instability analysis based on a one-dimensional high-gain free electron laser model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tsai, Cheng-Ying; Wu, Juhao; Yang, Chuan

    When an untapered high-gain free electron laser (FEL) reaches saturation, the exponential growth ceases and the radiation power starts to oscillate about an equilibrium. The FEL radiation power or efficiency can be increased by undulator tapering. For a high-gain tapered FEL, although the power is enhanced after the first saturation, it is known that there is a so-called second saturation where the FEL power growth stops even with a tapered undulator system. The sideband instability is one of the primary reasons leading to this second saturation. In this paper, we provide a quantitative analysis on how the gradient of undulatormore » tapering can mitigate the sideband growth. The study is carried out semianalytically and compared with one-dimensional numerical simulations. The physical parameters are taken from Linac Coherent Light Source-like electron bunch and undulator systems. The sideband field gain and the evolution of the radiation spectra for different gradients of undulator tapering are examined. It is found that a strong undulator tapering (~10 % ) provides effective suppression of the sideband instability in the postsaturation regime.« less

  1. Periodization effects during short-term resistance training with equated exercise variables in females.

    PubMed

    Pelzer, Thiemo; Ullrich, Boris; Pfeiffer, Mark

    2017-03-01

    During resistance training, volume and load can be altered either gradually (traditional periodization: TP) or with frequent changes between subsequent sessions (daily undulating periodization: DUP). We hypothesized that the periodization model employed would not impact upon training-induced adaptations when exercise variables are equated. Nineteen females (22.0 years, moderate resistance training experience of 27.9 months) performed 6 weeks of knee extensor training with 3 weekly sessions exercising one leg using TP and the contralateral leg using DUP. Training load varied between 40, 60, and 80% of one repetition maximum (1RM). Volume, range of motion, and time under tension were equated for each leg with a biofeedback software. Dynamometry, surface EMG and ultrasonography were used to determine temporal changes of knee extensor maximum voluntary strength (MVC), neural drive of the M. quadriceps femoris (QF) and vastus lateralis (VL) and rectus femoris (RF) muscle architecture. Significant (P < 0.05) gains for isometric (TP 15%, DUP 13%) and isokinetic-concentric (TP 8%, DUP 10%) MVC and knee extensor 1RM (TP 18%, DUP 24%) occurred post training. VL and RF-muscle thickness showed significant (P < 0.05) increases ranging from 12 to 20% for TP and from 13 to 19% for DUP. Furthermore, significant (P < 0.05) increases in VL-pennation angle and VL-fascicle length occurred in both legs while QF EMG remained unchanged. No significant temporal differences were found between both models, displaying similar small to large effect sizes. Periodization is no adaptation trigger during short-term resistance training with equated exercise variables.

  2. BPM CALIBRATION INDEPENDENT LHC OPTICS CORRECTION

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    CALAGA,R.; TOMAS, R.; GIOVANNOZZI, M.

    2007-06-25

    The tight mechanical aperture for the LHC imposes severe constraints on both the beta and dispersion beating. Robust techniques to compensate these errors are critical for operation of high intensity beams in the LHC. We present simulations using realistic errors from magnet measurements and alignment tolerances in the presence of BPM noise. Correction reveals that the use of BPM calibration and model independent observables are key ingredients to accomplish optics correction. Experiments at RHIC to verify the algorithms for optics correction are also presented.

  3. Evaluation of Heat Dissipation in the BPM Buttons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pinayev,I.; Blednyhk, A.

    2009-05-04

    Growth of circulating current in the storage rings drastically increases heating of the beam position monitor (BPM) buttons due to the induced trapped modes is drastically increasing. Excessive heating can lead to the errors in the measuring of beam position or even catastrophic failures of the pick-up assembly. In this paper we present calculations of heat generated in the button for different geometries and materials. The obtained results are used for the optimization of the NSLS-II BPM buttons design.

  4. A BPM calibration procedure using TBT data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, M.J.; Crisp, J.; Prieto, P.

    2007-06-01

    Accurate BPM calibration is crucial for lattice analysis. It is also reassuring when the calibration can be independently verified. This paper outlines a procedure that can extract BPM calibration information from TBT orbit data. The procedure is developed as an extension to the Turn-By-Turn lattice analysis [1]. Its application to data from both Recycler Ring and Main Injector (MI) at Fermilab have produced very encouraging results. Some specifics in hardware design will be mentioned to contrast that of analysis results.

  5. Deep-Diving California Sea Lions: Are They Pushing Their Physiological Limit

    DTIC Science & Technology

    2015-09-30

    resting heart rate (70 bpm ) (Ponganis et al. 1997) is reached, and e) duration of and heart rate during the ascent tachycardia. If possible, heart rate...Resting heart rates were 54 + 6 beats min-1 ( bpm ), and in dives of 1-3 min, 3-5 min, and > 5 min, dive heart rates (number of beats/dive duration...were 55 + 8, 51 + 6, and 40 + bpm . As illustrated in Figs. 1 and 2, the heart rate profile was characterized by rapid development of a bradycardia

  6. Development and operating experience of a 1.1-m-long superconducting undulator at the Advanced Photon Source

    DOE PAGES

    Ivanyushenkov, Y.; Harkay, K.; Borland, M.; ...

    2017-10-03

    Development of superconducting undulators continues at the Advanced Photon Source (APS). Two years after successful installation and commissioning of the first relatively short superconducting undulator “SCU0” in Sector 6 of the APS storage ring, the second 1.1-m long superconducting undulator “SCU1” was installed in Sector 1 of the APS. The device has been in user operation since its commissioning in May 2015. This paper describes the magnetic and cryogenic design of the SCU1 together with the results of stand-alone cold tests. The SCU1’s magnetic and cryogenic performance as well as its operating experience in the APS storage ring are alsomore » presented.« less

  7. Development and operating experience of a 1.1-m-long superconducting undulator at the Advanced Photon Source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ivanyushenkov, Y.; Harkay, K.; Borland, M.

    Development of superconducting undulators continues at the Advanced Photon Source (APS). Two years after successful installation and commissioning of the first relatively short superconducting undulator “SCU0” in Sector 6 of the APS storage ring, the second 1.1-m long superconducting undulator “SCU1” was installed in Sector 1 of the APS. The device has been in user operation since its commissioning in May 2015. This paper describes the magnetic and cryogenic design of the SCU1 together with the results of stand-alone cold tests. The SCU1’s magnetic and cryogenic performance as well as its operating experience in the APS storage ring are alsomore » presented.« less

  8. Increased Heart Rate Is Associated With Higher Mortality in Patients With Atrial Fibrillation (AF): Results From the Outcomes Registry for Better Informed Treatment of AF (ORBIT-AF)

    PubMed Central

    Steinberg, Benjamin A; Kim, Sunghee; Thomas, Laine; Fonarow, Gregg C; Gersh, Bernard J; Holmqvist, Fredrik; Hylek, Elaine; Kowey, Peter R; Mahaffey, Kenneth W; Naccarelli, Gerald; Reiffel, James A; Chang, Paul; Peterson, Eric D; Piccini, Jonathan P

    2015-01-01

    Background Most patients with atrial fibrillation (AF) require rate control; however, the optimal target heart rate remains under debate. We aimed to assess rate control and subsequent outcomes among patients with permanent AF. Methods and Results We studied 2812 US outpatients with permanent AF in the Outcomes Registry for Better Informed Treatment of Atrial Fibrillation. Resting heart rate was measured longitudinally and used as a time-dependent covariate in multivariable Cox models of all-cause and cause-specific mortality during a median follow-up of 24 months. At baseline, 7.4% (n=207) had resting heart rate <60 beats per minute (bpm), 62% (n=1755) 60 to 79 bpm, 29% (n=817) 80 to 109 bpm, and 1.2% (n=33) ≥110 bpm. Groups did not differ by age, previous cerebrovascular disease, heart failure status, CHA2DS2-VASc scores, renal function, or left ventricular function. There were significant differences in race (P=0.001), sinus node dysfunction (P=0.004), and treatment with calcium-channel blockers (P=0.006) and anticoagulation (P=0.009). In analyses of continuous heart rates, lower heart rate ≤65 bpm was associated with higher all-cause mortality (adjusted hazard ratio [HR], 1.15 per 5-bpm decrease; 95% CI, 1.01 to 1.32; P=0.04). Similarly, increasing heart rate >65 bpm was associated with higher all-cause mortality (adjusted HR, 1.10 per 5-bpm increase; 95% CI, 1.05 to 1.15; P<0.0001). This relationship was consistent across endpoints and in a broader sensitivity analysis of permanent and nonpermanent AF patients. Conclusions Among patients with permanent AF, there is a J-shaped relationship between heart rate and mortality. These data support current guideline recommendations, and clinical trials are warranted to determine optimal rate control. Clinical Trial Registration URL: http://clinicaltrials.gov/. Unique identifier: NCT01165710. PMID:26370445

  9. Evaluation of anti-asthmatic and antioxidant potential of Boerhavia procumbens in toluene diisocyanate (TDI) treated rats.

    PubMed

    Bokhari, Jasia; Khan, Muhammad Rashid

    2015-08-22

    Asthma is an ailment of airways characterized by activation of the T helper (Th) 2 lymphocytes and subsequent movement of inflammatory cells. Boerhavia procumbens of family Nyctaginaceae is locally used for the treatment of asthma, cough, hemorrhoids, dropsy, cardiac, eyes and kidney problems. We have evaluated its methanol extract (BPM) as a therapeutic candidate for asthma against toluene diisocyanate (TDI) allergic model in rat. The BPM extract was obtained from the whole plant of B. procumbens in methanol. Sprague-Dawley male 36 rats (200-250 g) were categorized into 6 groups having six rats in each category. The animals were provoked (10%) and sensitized (5%) by TDI. Animals of groups I-III were vehicle control (ethyl acetate), diseased control (TDI) and reference control (TDI+dexamethasone {2.5mg/kg bw}), respectively. Animals of group IV (TDI+200mg/kg bw) and group V (TDI+400mg/kg bw) were administered with BPM whereas group VI was administered with 400mg/kg bw alone of BPM. Protective effects of BPM were determined by counting the number of leucocytes and estimation of interleukines in blood, bronchoalveolar lavage (BAL) and in in vitro culture of spleen cells. Estimation of antioxidant enzymes, lipid peroxides and H2O2 and histopathology of lungs were carried out for antioxidant potential of plant extract used. Methanol extract of B. procumbens suppressed the asthmatic symptoms and inhibited the infiltration of eosinophils and lymphocytes in lungs of TDI provoked rats. Administration of BPM to TDI provoked rats, dose dependently, inhibited the release of interleukins (IL)-2 in serum and IL-4, IL-6 interferon gamma (IFN-γ) in bronchoalveolar lavage (BAL) and in in vitro culture of spleen cells, and ameliorated the oxidative stress in lung tissues. Quantitative scoring of the lung histopathology exhibited protective effects of BPM and the inflammation, mucus, thickening of peribronchial smooth muscle layer and subepithelial deposition of collagen induced with TDI were ameliorated. The BPM has the anti-inflammatory properties that may be used to treat the asthma and inflammatory related ailments. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  10. A preliminary study of a running speed based heart rate prediction during an incremental treadmill exercise.

    PubMed

    Dae-Geun Jang; Byung-Hoon Ko; Sub Sunoo; Sang-Seok Nam; Hun-Young Park; Sang-Kon Bae

    2016-08-01

    This preliminary study investigates feasibility of a running speed based heart rate (HR) prediction. It is basically motivated from the assumption that there is a significant relationship between HR and the running speed. In order to verify the assumption, HR and running speed data from 217 subjects of varying aerobic capabilities were simultaneously collected during an incremental treadmill exercise. A running speed was defined as a treadmill speed and its corresponding heart rate was calculated by averaging the last one minute HR values of each session. The feasibility was investigated by assessing a correlation between the heart rate and the running speed using inter-subject (between-subject) and intra-subject (within-subject) datasets with regression orders of 1, 2, 3, and 4, respectively. Furthermore, HR differences between actual and predicted HRs were also employed to investigate the feasibility of the running speed in predicting heart rate. In the inter-subject analysis, a strong positive correlation and a reasonable HR difference (r = 0.866, 16.55±11.24 bpm @ 1st order; r = 0.871, 15.93±11.49 bpm @ 2nd order; r = 0.897, 13.98±10.80 bpm @ 3rd order; and r = 0.899, 13.93±10.64 bpm @ 4th order) were obtained, and a very high positive correlation and a very low HR difference (r = 0.978, 6.46±3.89 bpm @ 1st order; r = 0.987, 5.14±2.87 bpm @ 2nd order; r = 0.996, 2.61±2.03 bpm @ 3rd order; and r = 0.997, 2.04±1.73 bpm @ 4th order) were obtained in the intra-subject analysis. It can therefore be concluded that 1) heart rate is highly correlated with a running speed; 2) heart rate can be approximately estimated by a running speed with a proper statistical model (e.g., 3rd-order regression); and 3) an individual HR-speed calibration process may improve the prediction accuracy.

  11. Increased Heart Rate Is Associated With Higher Mortality in Patients With Atrial Fibrillation (AF): Results From the Outcomes Registry for Better Informed Treatment of AF (ORBIT-AF).

    PubMed

    Steinberg, Benjamin A; Kim, Sunghee; Thomas, Laine; Fonarow, Gregg C; Gersh, Bernard J; Holmqvist, Fredrik; Hylek, Elaine; Kowey, Peter R; Mahaffey, Kenneth W; Naccarelli, Gerald; Reiffel, James A; Chang, Paul; Peterson, Eric D; Piccini, Jonathan P

    2015-09-14

    Most patients with atrial fibrillation (AF) require rate control; however, the optimal target heart rate remains under debate. We aimed to assess rate control and subsequent outcomes among patients with permanent AF. We studied 2812 US outpatients with permanent AF in the Outcomes Registry for Better Informed Treatment of Atrial Fibrillation. Resting heart rate was measured longitudinally and used as a time-dependent covariate in multivariable Cox models of all-cause and cause-specific mortality during a median follow-up of 24 months. At baseline, 7.4% (n=207) had resting heart rate <60 beats per minute (bpm), 62% (n=1755) 60 to 79 bpm, 29% (n=817) 80 to 109 bpm, and 1.2% (n=33) ≥110 bpm. Groups did not differ by age, previous cerebrovascular disease, heart failure status, CHA2DS2-VASc scores, renal function, or left ventricular function. There were significant differences in race (P=0.001), sinus node dysfunction (P=0.004), and treatment with calcium-channel blockers (P=0.006) and anticoagulation (P=0.009). In analyses of continuous heart rates, lower heart rate ≤65 bpm was associated with higher all-cause mortality (adjusted hazard ratio [HR], 1.15 per 5-bpm decrease; 95% CI, 1.01 to 1.32; P=0.04). Similarly, increasing heart rate >65 bpm was associated with higher all-cause mortality (adjusted HR, 1.10 per 5-bpm increase; 95% CI, 1.05 to 1.15; P<0.0001). This relationship was consistent across endpoints and in a broader sensitivity analysis of permanent and nonpermanent AF patients. Among patients with permanent AF, there is a J-shaped relationship between heart rate and mortality. These data support current guideline recommendations, and clinical trials are warranted to determine optimal rate control. URL: http://clinicaltrials.gov/. Unique identifier: NCT01165710. © 2015 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  12. CCISS, Vascular and BP Reg: Canadian space life science research on ISS

    NASA Astrophysics Data System (ADS)

    Hughson, Richard L.; Shoemaker, J. Kevin; Arbeille, Philippe

    2014-11-01

    A comprehensive goal of the Canadian Space Agency studies (CCISS, Vascular and BP Reg) has been to investigate the efficacy of current exercise countermeasures to maintain cardiovascular and cerebrovascular health on return to Earth after up to 6-months in space. Results from the CCISS experiments revealed no significant change of in-flight heart rate during daily activities or sleep, and small, but variable between astronauts, post-flight elevation. The between astronaut differences were exaggerated during measurement of spontaneous baroreflex slope, which was reduced post-flight (P<0.05) during paced breathing with 3 astronauts having significant correlations between reduced baroreflex and reduced RR-interval (consistent with reduced fitness). Cerebrovascular autoregulation and CO2 response were mildly impaired after flight. Some loss of in-flight fitness of astronauts in Vascular was reflected by the increase in HR at a work rate of 161±46 W of 12.3±10.5 bpm, 10.4±5.9 bpm and 13.4±5.7 bpm for early-flight, late-flight and R+1, respectively. On return to gravity, changes in resting heart rate for supine (5.9±3.5 bpm), sit (8.1±3.3 bpm) and stand (10.3±10.0 bpm) were small but variable between individuals (from -5 bpm to +20 bpm in post-flight standing) and not related to the change in exercise heart rate. In Vascular astronauts, pulse wave transit time measured to the finger tended to be reduced post-flight and carotid artery distensibility was significantly reduced (P=0.03, and n=6). The heart rate and baroreflex data suggest that some astronauts return with cardiovascular deconditioning in spite of the exercise regimes. However, greater arterial stiffness is common among all astronauts studied to date. The new CSA project, BP Reg, will monitor inflight blood pressure in an attempt to identify astronauts in greater need for countermeasures. Future research should focus on whether Vascular changes in astronauts might make them an appropriate model to study the mechanisms of arterial aging on Earth.

  13. Concurrent validity of resting pulse-rate measurements: a comparison of 2 smartphone applications, the polar H7 belt monitor, and a pulse oximeter with bluetooth.

    PubMed

    Cheatham, Scott W; Kolber, Morey J; Ernst, Michael P

    2015-05-01

    Pulse rate is commonly measured manually or with commercial wrist or belt monitors. More recently, pulse-rate monitoring has become convenient with the use of mobile technology that allows monitoring through a smartphone camera. This optical technology offers many benefits, although the clinimetric properties have not been extensively studied. Observational study of reliability Setting: University kinesiology laboratory. 30 healthy, recreationally active adults. Concurrent measurement of pulse rate using 2 smartphone applications (fingertip, face-scan,) with the Polar H7 belt and pulse oximeter. Average resting pulse rate for 5 min in 3 positions (supine, sitting, and prone). Concurrent validity in supine and standing was good between the 2 applications and the Polar H7 (intraclass correlation coefficient [ICC] .80-.98) and pulse oximeter (ICC .82-.98). For sitting, the validity was good between the fingertip application, Polar H7 (ICC .97), and pulse oximeter (ICC .97). The face-scan application had moderate validity with the Polar H7 (ICC .74) and pulse oximeter (ICC .69). The minimal detectable change (MDC90) between the fingertip application and Polar H7 ranged from 1.38 to 4.36 beats/min (BPM) and from 0.69 to 2.97 BPM for the pulse oximeter with both positions. The MDC90 between the face-scan application and Polar H7 ranged from 11.88 to 12.83 BPM and from 0.59 to 17.72 BPM for the pulse oximeter. The 95% limits of agreement suggest that the fingertip application may vary between 2.40 and 3.59 BPM with the Polar H7 and between 3.40 and 3.42 BPM with the pulse oximeter. The face-scan application may vary between 3.46 and 3.52 BPM with the Polar H7 and between 2.54 and 3.46 BPM with the pulse oximeter. Pulse-rate measurements may be effective using a fingertip application, belt monitor, and pulse oximeter. The fingertip scanner showed superior results compared with the face scanner, which only demonstrated modest validity compared with the Polar H7 and pulse oximeter.

  14. Bladder pressure measurements and urinary tract infection in trauma patients.

    PubMed

    Duane, Therèse M; Young, Andrew; Weber, William; Wolfe, Luke G; Malhotra, Ajai K; Aboutanos, Michel B; Whelan, James F; Mayglothling, Julie; Ivatury, Rao R

    2012-04-01

    The purpose of this trial was to determine if using a closed technique for bladder pressure measurements (BPMs) would eliminate them as a risk factor for urinary tract infection (UTI) in trauma patients, as was shown previously using an open technique. Data were collected prospectively from January 2006 until December 2009 by a dedicated epidemiology nurse and combined with trauma registry data at our Level 1 trauma center. All trauma patients admitted to the surgical trauma intensive care unit (STICU) with and without UTIs were compared for demographic and epidemiologic data. A closed system was used in which the urinary drainage catheter (UDC) remained connected to the bag and 45 mL of saline was injected through a two-way valved sideport, with subsequent measurements through the sideport. There were 1,641 patients in the trial. The UTI group was sicker (Injury Severity Score [ISS] 18.7±11.9 no UTI vs. 28±10.7 UTI; p<0.0001), with longer stays (11.4±12.4 days no UTI vs. 37.9±20.3 days UTI; p<0.0001) and more UDC days (4.3±6.6 no UTI vs. 23.9±16.6 UTI; p<0.0001). The BPM group had more UDC days (15.6 days±16.0 BPM vs. 5.4 days±7.3 no BPM; p<0.0001), yet no difference in UTI rate/1,000 UDC days (5.7 no BPM vs. 8.0 BPM; p=0.5291). Logistic regression demonstrated only UDC days to be a predictor of UTI (1.125; 95% confidence interval [CI] 1.097-1.154; p<0.0001), whereas ISS (1.083, 95% CI 1.063-1.104; p<0.0001) and age (1.051, 95% CI 1.037-1.065; p<0.0001) were the only predictors of death. Although patients undergoing BPM have more UTIs than patients without BPM, the measurements are not an independent predictor of UTI when done by the closed technique. These findings emphasize the judicious use of BPM with a closed system and, more importantly, the need for early removal of catheters.

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gluskin, Efim; Trakhtenberg, Emil; Xu, Joseph Z.

    A method and apparatus for implementing dynamic compensation of magnetic forces for undulators are provided. An undulator includes a respective set of magnet arrays, each attached to a strongback, and placed on horizontal slides and positioned parallel relative to each other with a predetermined gap. Magnetic forces are compensated by a set of compensation springs placed along the strongback. The compensation springs are conical springs having exponential-force characteristics that substantially match undulator magnetic forces independently of the predetermined gap. The conical springs are positioned along the length of the magnets.

  16. Improvement of the thermo-mechanical position stability of the beam position monitor in the PLS-II

    NASA Astrophysics Data System (ADS)

    Ha, Taekyun; Hong, Mansu; Kwon, Hyuckchae; Han, Hongsik; Park, Chongdo

    2016-09-01

    In the storage ring of the Pohang Light Source-II (PLS-II), we reduced the mechanical displacement of the electron-beam position monitors (e-BPMs) that is caused by heating during e-beam storage. The BPM pickup itself must be kept stable to sub-micrometer precision in order for a stable photon beam to be provided to beamlines because the orbit feedback system is programmed to make the electron beam pass through the center of the BPM. Thermal deformation of the vacuum chambers on which the BPM pickups are mounted is inevitable when the electron beam current is changed by an unintended beam abort. We reduced this deformation by improving the vacuum chamber support and by enhancing the water cooling. We report a thermo-mechanical analysis and displacement measurements for the BPM pickups after improvements.

  17. Correlation of radiation dose and heart rate in dual-source computed tomography coronary angiography.

    PubMed

    Laspas, Fotios; Tsantioti, Dimitra; Roussakis, Arkadios; Kritikos, Nikolaos; Efthimiadou, Roxani; Kehagias, Dimitrios; Andreou, John

    2011-04-01

    Computed tomography coronary angiography (CTCA) has been widely used since the introduction of 64-slice scanners and dual-source CT technology, but the relatively high radiation dose remains a major concern. To evaluate the relationship between radiation exposure and heart rate (HR), in dual-source CTCA. Data from 218 CTCA examinations, performed with a dual-source 64-slices scanner, were statistically evaluated. Effective radiation dose, expressed in mSv, was calculated as the product of the dose-length product (DLP) times a conversion coefficient for the chest (mSv = DLPx0.017). Heart rate range and mean heart rate, expressed in beats per minute (bpm) of each individual during CTCA, were also provided by the system. Statistical analysis of effective dose and heart rate data was performed by using Pearson correlation coefficient and two-sample t-test. Mean HR and effective dose were found to have a borderline positive relationship. Individuals with a mean HR >65 bpm observed to receive a statistically significant higher effective dose as compared to those with a mean HR ≤65 bpm. Moreover, a strong correlation between effective dose and variability of HR of more than 20 bpm was observed. Dual-source CT scanners are considered to have the capability to provide diagnostic examinations even with high HR and arrhythmias. However, it is desirable to keep the mean heart rate below 65 bpm and heart rate fluctuation less than 20 bpm in order to reduce the radiation exposure.

  18. Advances in industrial biopharmaceutical batch process monitoring: Machine-learning methods for small data problems.

    PubMed

    Tulsyan, Aditya; Garvin, Christopher; Ündey, Cenk

    2018-04-06

    Biopharmaceutical manufacturing comprises of multiple distinct processing steps that require effective and efficient monitoring of many variables simultaneously in real-time. The state-of-the-art real-time multivariate statistical batch process monitoring (BPM) platforms have been in use in recent years to ensure comprehensive monitoring is in place as a complementary tool for continued process verification to detect weak signals. This article addresses a longstanding, industry-wide problem in BPM, referred to as the "Low-N" problem, wherein a product has a limited production history. The current best industrial practice to address the Low-N problem is to switch from a multivariate to a univariate BPM, until sufficient product history is available to build and deploy a multivariate BPM platform. Every batch run without a robust multivariate BPM platform poses risk of not detecting potential weak signals developing in the process that might have an impact on process and product performance. In this article, we propose an approach to solve the Low-N problem by generating an arbitrarily large number of in silico batches through a combination of hardware exploitation and machine-learning methods. To the best of authors' knowledge, this is the first article to provide a solution to the Low-N problem in biopharmaceutical manufacturing using machine-learning methods. Several industrial case studies from bulk drug substance manufacturing are presented to demonstrate the efficacy of the proposed approach for BPM under various Low-N scenarios. © 2018 Wiley Periodicals, Inc.

  19. Effects of rhythmical and extra-rhythmical qualities of music on heart rate during stationary bike activities.

    PubMed

    DI Cagno, Alessandra; Iuliano, Enzo; Fiorilli, Giovanni; Aquino, Giovanna; Giombini, Arrigo; Menotti, Federica; Tsopani, Despina; Calcagno, Giuseppe

    2016-10-01

    The aim of this study was to evaluate the effects of rhythmical and extra-rhythmical qualities of music on the heart rate (HR) and rates of perceived exertion (RPE), during sub-maximal stationary bike activity. HR of 28 female adult participants was monitored during 3 session of physical activity, performed under 3 different conditions: Hi-BPM (music with 150-170 BPM), RHYTHM (rhythmical qualities only of Hi-BPM condition) and control condition without music (CONTROL). Four parameters were analyzed: the highest HR value (High-HR), High-HR minus starting HR (∆HR), time to reach the 75% of Maximal HR (MHR) (TimeTo75%) and time over 75% MHR (TimeOver75%). HR trend analysis was performed to evaluate differences among the three conditions. OMNI-Cycle Scale was administered to evaluate RPE. MANOVA showed significant differences between the three conditions in TimeTo75%, ∆HR (P<0.01) and TimeOver75% (P<0.05). In RHYTHM and CONTROL conditions after reaching 75% MHR, the HR increase were significantly lower than Hi-BPM (P<0.01). No significant differences were found in OMNI-Cycle Scale scores of Hi-BPM and RHYTHM whereas RPE was significantly higher in CONTROL condition (P<0.05). Hi-BPM and RHYTHM music allowed a faster reaching of the aerobic training zone compared to CONTROL conditions. Nevertheless, after 75% MHR, extra-rhythmical qualities are necessary to maintain or to increase the working HR levels.

  20. Adherence to optimal heart rate control in heart failure with reduced ejection fraction: insight from a survey of heart rate in heart failure in Sweden (HR-HF study).

    PubMed

    Fu, M; Ahrenmark, U; Berglund, S; Lindholm, C J; Lehto, A; Broberg, A Månsson; Tasevska-Dinevska, G; Wikstrom, G; Ågard, A; Andersson, B

    2017-12-01

    Despite that heart rate (HR) control is one of the guideline-recommended treatment goals for heart failure (HF) patients, implementation has been painstakingly slow. Therefore, it would be important to identify patients who have not yet achieved their target heart rates and assess possible underlying reasons as to why the target rates are not met. The survey of HR in patients with HF in Sweden (HR-HF survey) is an investigator-initiated, prospective, multicenter, observational longitudinal study designed to investigate the state of the art in the control of HR in HF and to explore potential underlying mechanisms for suboptimal HR control with focus on awareness of and adherence to guidelines for HR control among physicians who focus on the contributing role of beta-blockers (BBs). In 734 HF patients the mean HR was 68 ± 12 beats per minute (bpm) (37.2% of the patients had a HR >70 bpm). Patients with HF with reduced ejection fraction (HFrEF) (n = 425) had the highest HR (70 ± 13 bpm, with 42% >70 bpm), followed by HF with preserved ejection fraction and HF with mid-range ejection fraction. Atrial fibrillation, irrespective of HF type, had higher HR than sinus rhythm. A similar pattern was observed with BB treatment. Moreover, non-achievement of the recommended target HR (<70 bpm) in HFrEF and sinus rhythm was unrelated to age, sex, cardiovascular risk factors, cardiovascular diseases, and comorbidities, but was related to EF and the clinical decision of the physician. Approximately 50% of the physicians considered a HR of >70 bpm optimal and an equal number considered a HR of >70 bpm too high, but without recommending further action. Furthermore, suboptimal HR control cannot be attributed to the use of BBs because there was neither a difference in use of BBs nor an interaction with BBs for HR >70 bpm compared with HR <70 bpm. Suboptimal control of HR was noted in HFrEF with sinus rhythm, which appeared to be attributable to physician decision making rather than to the use of BBs. Therefore, our results underline the need for greater attention to HR control in patients with HFrEF and sinus rhythm and thus a potential for improved HF care.

  1. Design and Fabrication of Soft Morphing Ray Propulsor: Undulator and Oscillator.

    PubMed

    Kim, Hyung-Soo; Lee, Jang-Yeob; Chu, Won-Shik; Ahn, Sung-Hoon

    2017-03-01

    A soft morphing ray propulsor capable of generating an undulating motion in its pectoral fins was designed and fabricated. The propulsor used shape memory alloy for actuation, and the body was made with soft polymers. To determine the effects of undulation in the fins, two models that differed in terms of the presence of undulation were fabricated using different polymer materials. The experimental models were tested with a dynamometer to measure and compare thrust tendencies. Thrust measurements were conducted with various fin beat frequencies. Using the experimental data, the concept of an optimized standalone version of the ray robot was suggested and its prototype was fabricated. The fabricated robot was able to swim as fast as 0.26 body length per second and 38% more efficient than other smart material-based ray-like underwater robots.

  2. A literature review on business process modelling: new frontiers of reusability

    NASA Astrophysics Data System (ADS)

    Aldin, Laden; de Cesare, Sergio

    2011-08-01

    Business process modelling (BPM) has become fundamental for modern enterprises due to the increasing rate of organisational change. As a consequence, business processes need to be continuously (re-)designed as well as subsequently aligned with the corresponding enterprise information systems. One major problem associated with the design of business processes is reusability. Reuse of business process models has the potential of increasing the efficiency and effectiveness of BPM. This article critically surveys the existing literature on the problem of BPM reusability and more specifically on that State-of-the-Art research that can provide or suggest the 'elements' required for the development of a methodology aimed at discovering reusable conceptual artefacts in the form of patterns. The article initially clarifies the definitions of business process and business process model; then, it sets out to explore the previous research conducted in areas that have an impact on reusability in BPM. The article concludes by distilling directions for future research towards the development of apatterns-based approach to BPM; an approach that brings together the contributions made by the research community in the areas of process mining and discovery, declarative approaches and ontologies.

  3. BEAM DIAGNOSTICS USING BPM SIGNALS FROM INJECTED AND STORED BEAMS IN A STORAGE RING

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, G.M.; Shaftan; T.

    2011-03-28

    Many modern light sources are operating in top-off injection mode or are being upgraded to top-off injection mode. The storage ring always has the stored beam and injected beam for top-off injection mode. So the BPM data is the mixture of both beam positions and the injected beam position cannot be measured directly. We propose to use dedicated wide band BPM electronics in the NSLS II storage ring to retrieve the injected beam trajectory with the singular value decomposition (SVD) method. The beam position monitor (BPM) has the capability to measure bunch-by-bunch beam position. Similar electronics can be used tomore » measure the bunch-by-bunch beam current which is necessary to get the injection beam position. The measurement precision of current needs to be evaluated since button BPM sum signal has position dependence. The injected beam trajectory can be measured and monitored all the time without dumping the stored beam. We can adjust and optimize the injected beam trajectory to maximize the injection efficiency. We can also measure the storage ring acceptance by mapping the injected beam trajectory.« less

  4. Event-synchronized data acquisition system for the SPring-8 linac beam position monitors

    NASA Astrophysics Data System (ADS)

    Masuda, T.; Fukui, T.; Tanaka, R.; Taniuchi, T.; Yamashita, A.; Yanagida, K.

    2005-05-01

    By the summer of 2003, we had completed the installation of a new non-destructive beam position monitor (BPM) system to facilitate beam trajectory and energy correction for the SPring-8 linac. In all, 47 BPM sets were installed on the 1-GeV linac and three beam-transport lines. All of the BPM data acquisition system was required to operate synchronously with the electron beam acceleration cycle. We have developed an event-synchronized data acquisition system for the BPM data readout. We have succeeded in continuously taking all the BPMs data from six VME computers synchronized with the 10 pps operation of the linac to continuously acquire data. For each beam shot, the data points are indexed by event number and stored in a database. Using the real-time features of the Solaris operating system and distributed database technology, we currently have achieved about 99.9% efficiency in capturing and archiving all of the 10 Hz data. The linac BPM data is available for off-line analysis of the beam trajectory, but also for real-time control and automatic correction of the beam trajectory and energy.

  5. Analysis of the orbit distortion by the use of the wavelet transform

    NASA Astrophysics Data System (ADS)

    Matsushita, T.; Agui, A.; Yoshigoe, A.; Takao, M.; Aoyagi, H.; Takeuchi, M.; Nakatani, T.; Tanaka, H.

    2004-05-01

    We have adopted matching pursuit algorithm of discrete wavelet transform (DWT) for the analysis of the beam position shift correlated with the motion of insertion device(ID). The beam position data measured by the rf beam position monitors have included high-frequency `noises' and fluctuation of background level. Precise evaluation of the electron beam position shift correlated with the motion of the ID is required for estimation of the steering magnet currents in order to suppress the closed orbit distortion (COD). The DWT is a powerful tool for frequency analysis and data processing. The analysis of DWT was applied to the beam position shift correlated with the phase motion of APPLE-2 type undulator (ID23) in SPring-8. The result of the analysis indicated that `noises' are mainly composed of the components of 50 ˜ 6.25Hz and < 0.1Hz. We carried out the data processing to remove the `noises' by the matching pursuit algorithm. Then we have succeeded in suppressing the COD within 2 μm by the use of the steering magnet currents calculated from the processed data.

  6. The SPARC_LAB femtosecond synchronization for electron and photon pulsed beams

    NASA Astrophysics Data System (ADS)

    Bellaveglia, M.; Gallo, A.; Piersanti, L.; Pompili, R.; Gatti, G.; Anania, M. P.; Petrarca, M.; Villa, F.; Chiadroni, E.; Biagioni, A.; Mostacci, A.

    2015-05-01

    The SPARC LAB complex hosts a 150 MeV electron photo-injector equipped with an undulator for FEL production (SPARC) together with a high power TW laser (FLAME). Recently the synchronization system reached the performance of < 100 fsRMS relative jitter between lasers, electron beam and RF accelerating fields. This matches the requirements for next future experiments: (i) the production of X-rays by means of Thomson scattering (first collisions achieved in 2014) and (ii) the particle driven PWFA experiment by means of multiple electron bunches. We report about the measurements taken during the machine operation using BAMs (Bunch Arrival Monitors) and EOS (Electro-Optical Sampling) system. A new R and D activity concerning the LWFA using the external injection of electron bunches in a plasma generated by the FLAME laser pulse is under design. The upgrade of the synchronization system is under way to guarantee the < 30 fs RMS jitter required specification. It foresees the transition from electrical to optical architecture that mainly affects the reference signal distribution and the time of arrival detection performances. The new system architecture is presented together with the related experimental data.

  7. An undulator based soft x-ray source for microscopy on the Duke electron storage ring

    NASA Astrophysics Data System (ADS)

    Johnson, Lewis Elgin

    1998-09-01

    This dissertation describes the design, development, and installation of an undulator-based soft x-ray source on the Duke Free Electron Laser laboratory electron storage ring. Insertion device and soft x-ray beamline physics and technology are all discussed in detail. The Duke/NIST undulator is a 3.64-m long hybrid design constructed by the Brobeck Division of Maxwell Laboratories. Originally built for an FEL project at the National Institute of Standards and Technology, the undulator was acquired by Duke in 1992 for use as a soft x-ray source for the FEL laboratory. Initial Hall probe measurements on the magnetic field distribution of the undulator revealed field errors of more than 0.80%. Initial phase errors for the device were more than 11 degrees. Through a series of in situ and off-line measurements and modifications we have re-tuned the magnet field structure of the device to produce strong spectral characteristics through the 5th harmonic. A low operating K has served to reduce the effects of magnetic field errors on the harmonic spectral content. Although rms field errors remained at 0.75%, we succeeded in reducing phase errors to less than 5 degrees. Using trajectory simulations from magnetic field data, we have computed the spectral output given the interaction of the Duke storage ring electron beam and the NIST undulator. Driven by a series of concerns and constraints over maximum utility, personnel safety and funding, we have also constructed a unique front end beamline for the undulator. The front end has been designed for maximum throughput of the 1st harmonic around 40A in its standard mode of operation. The front end has an alternative mode of operation which transmits the 3rd and 5th harmonics. This compact system also allows for the extraction of some of the bend magnet produced synchrotron and transition radiation from the storage ring. As with any well designed front end system, it also provides excellent protection to personnel and to the storage ring. A diagnostic beamline consisting of a transmission grating spectrometer and scanning wire beam profile monitor was constructed to measure the spatial and spectral characteristics of the undulator radiation. Test of the system with a circulating electron beam has confirmed the magnetic and focusing properties of the undulator, and verified that it can be used without perturbing the orbit of the beam.

  8. [Successful outcome of a pregnancy with an extremely low fetal heart rate (34 bpm) due to isolated complete heart block--case report].

    PubMed

    Hamela-Olkowska, Anita; Dangel, Joanna; Miszczak-Knecht, Maria

    2009-09-01

    Isolated complete congenital heart block (CHB) in the majority of cases is associated with the presence of autoantibodies to SSA (Ro) and SSB (La) antigens in the maternal serum. The prognosis is less favorable in fetuses with a ventricular rate < 55bpm. We have reported a case of a fetus with an isolated non-autoimmune CHB with an extremely low ventricular rate (34bpm) in which the outcome was favorable. In the neonate the non-compaction of the myocardium was diagnosed.

  9. Utilizing the N beam position monitor method for turn-by-turn optics measurements

    NASA Astrophysics Data System (ADS)

    Langner, A.; Benedetti, G.; Carlà, M.; Iriso, U.; Martí, Z.; de Portugal, J. Coello; Tomás, R.

    2016-09-01

    The N beam position monitor method (N -BPM) which was recently developed for the LHC has significantly improved the precision of optics measurements that are based on BPM turn-by-turn data. The main improvement is due to the consideration of correlations for statistical and systematic error sources, as well as increasing the amount of BPM combinations which are used to derive the β -function at one location. We present how this technique can be applied at light sources like ALBA, and compare the results with other methods.

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Couprie, M. E.; Benabderrahmane, C.; Berteaud, P.

    The SOLEIL storage ring presents a very high fraction of its circumference dedicated to accommodate Insertion Devices (ID). Over the 25 presently planned insertion devices presenting a large variety of systems, 16 have been already installed and commissioned in September 2009. The UV-VUV region is covered with electromagnetic devices, offering tuneable polarisations. An electromagnet/permanent magnet undulator using copper sheets coils for fast switching of the helicity is under construction. 13 APPLE-II type undulators, with period ranging from 80 down to 36 mm, provide photons in the 0.1-10 keV region, some of them featuring tapering or quasi-periodicity. Five U20 in vacuummore » undulators cover typically the 3-30 keV range whereas an in vacuum wiggler, with compensation of the magnetic forces via adequate springs will cover the 10-50 keV spectral domain. R and D on cryogenic in-vacuum undulator is also under progress. A magnetic chicane using permanent magnet dipoles has also been designed in order to accommodate two canted undulators on the same straight section. A wiggler dedicated to slicing (production of femto second long pulses) is also being designed, its radiation will also serve for an X-ray beamline.« less

  11. Undulator Radiation Damage Experience at LCLS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nuhn, H. D.; Field, C.; Mao, S.

    2015-01-06

    The SLAC National Accelerator Laboratory has been running the Linac Coherent Light Source (LCLS), the first x-ray Free Electron Laser since 2009. Undulator magnet damage from radiation, produced by the electron beam traveling through the 133-m long straight vacuum tube, has been and is a concern. A damage measurement experiment has been performed in 2007 in order to obtain dose versus damage calibrations. Radiation reduction and detection devices have been integrated into the LCLS undulator system. The accumulated radiation dose rate was continuously monitored and recorded. In addition, undulator segments have been routinely removed from the beamline to be checkedmore » for magnetic (50 ppm, rms) and mechanic (about 0.25 µm, rms) changes. A reduction in strength of the undulator segments is being observed, at a level, which is now clearly above the noise. Recently, potential sources for the observed integrated radiation levels have been investigated. The paper discusses the results of these investigation as well as comparison between observed damage and measured dose accumulations and discusses, briefly, strategies for the new LCLS-II upgrade, which will be operating at more than 300 times larger beam rate.« less

  12. Curvature-undulation coupling as a basis for curvature sensing and generation in bilayer membranes.

    PubMed

    Bradley, Ryan P; Radhakrishnan, Ravi

    2016-08-30

    We present coarse-grained molecular dynamics simulations of the epsin N-terminal homology domain interacting with a lipid bilayer and demonstrate a rigorous theoretical formalism and analysis method for computing the induced curvature field in varying concentrations of the protein in the dilute limit. Our theory is based on the description of the height-height undulation spectrum in the presence of a curvature field. We formulated an objective function to compare the acquired undulation spectrum from the simulations to that of the theory. We recover the curvature field parameters by minimizing the objective function even in the limit where the protein-induced membrane curvature is of the same order as the amplitude due to thermal undulations. The coupling between curvature and undulations leads to significant predictions: (i) Under dilute conditions, the proteins can sense a site of spontaneous curvature at distances much larger than their size; (ii) as the density of proteins increases the coupling focuses and stabilizes the curvature field to the site of the proteins; and (iii) the mapping of the protein localization and the induction of a stable curvature is a cooperative process that can be described through a Hill function.

  13. Curvature–undulation coupling as a basis for curvature sensing and generation in bilayer membranes

    PubMed Central

    Bradley, Ryan P.; Radhakrishnan, Ravi

    2016-01-01

    We present coarse-grained molecular dynamics simulations of the epsin N-terminal homology domain interacting with a lipid bilayer and demonstrate a rigorous theoretical formalism and analysis method for computing the induced curvature field in varying concentrations of the protein in the dilute limit. Our theory is based on the description of the height–height undulation spectrum in the presence of a curvature field. We formulated an objective function to compare the acquired undulation spectrum from the simulations to that of the theory. We recover the curvature field parameters by minimizing the objective function even in the limit where the protein-induced membrane curvature is of the same order as the amplitude due to thermal undulations. The coupling between curvature and undulations leads to significant predictions: (i) Under dilute conditions, the proteins can sense a site of spontaneous curvature at distances much larger than their size; (ii) as the density of proteins increases the coupling focuses and stabilizes the curvature field to the site of the proteins; and (iii) the mapping of the protein localization and the induction of a stable curvature is a cooperative process that can be described through a Hill function. PMID:27531962

  14. Differences Among a Modern Cohort of BRCA Mutation Carriers Choosing Bilateral Prophylactic Mastectomies Compared to Breast Surveillance.

    PubMed

    Gilbert, Elizabeth; Zabor, Emily C; Stempel, Michelle; Mangino, Debra; Heerdt, Alexandra; Pilewskie, Melissa

    2017-10-01

    Women with a BRCA mutation have significantly elevated breast cancer risk, which can be reduced by >90% with bilateral prophylactic mastectomy (BPM). We sought to compare a cohort of BRCA mutation carriers choosing BPM versus breast surveillance to better elucidate factors that may impact decision making. Women with a BRCA mutation were retrospectively identified from a prospectively maintained database. The surveillance cohort (n = 313) consisted of women seen in a high-risk clinic between 2014 and 2016, while the surgery cohort (n = 142) consisted of women who underwent BPM between 2010 and 2016. Clinical and familial factors were compared between the groups. Women choosing BPM were more likely to have a BRCA1 than BRCA2 mutation compared with the surveillance group (57 vs. 45%, p = 0.02) and were less likely to have a personal history of ovarian cancer (10 vs. 20%, p = 0.01). Furthermore, women undergoing BPM were more likely to be married (78 vs. 62%, p = 0.01), to have more children (median 2 vs. 1, p < 0.001), and to have undergone a prophylactic oophorectomy (61 vs. 37%, p < 0.001). Women choosing BPM had more first-degree relatives (63 vs. 48%, p = 0.01) or a sister (23 vs. 14%, p = 0.02) with a history of breast cancer and were more likely to have a family member with ovarian cancer under the age of 40 years (9 vs. 4%, p = 0.03). There was no difference in the number of prior breast biopsies or history of atypia/lobular carcinoma in situ. The decision to undergo BPM appears multifactorial, with gene mutation, family history, and relationships appearing to have the strongest influence on decision making.

  15. Heart Rate Dependency of Large Artery Stiffness.

    PubMed

    Tan, Isabella; Spronck, Bart; Kiat, Hosen; Barin, Edward; Reesink, Koen D; Delhaas, Tammo; Avolio, Alberto P; Butlin, Mark

    2016-07-01

    Carotid-femoral pulse wave velocity (cfPWV) quantifies large artery stiffness, it is used in hemodynamic research and is considered a useful cardiovascular clinical marker. cfPWV is blood pressure (BP) dependent. Intrinsic heart rate (HR) dependency of cfPWV is unknown because increasing HR is commonly accompanied by increasing BP. This study aims to quantify cfPWV dependency on acute, sympathovagal-independent changes in HR, independent of BP. Individuals (n=52, age 40-93 years, 11 female) with in situ cardiac pacemakers or cardioverter defibrillators were paced at 60, 70, 80, 90, and 100 bpm. BP and cfPWV were measured at each HR. Both cfPWV (mean [95% CI], 0.31 [0.26-0.37] m/s per 10 bpm; P<0.001) and central aortic diastolic pressure (3.78 [3.40-4.17] mm Hg/10 bpm; P<0.001) increased with HR. The HR effect on cfPWV was isolated by correcting the BP effects by 3 different methods: (1) statistically, by a linear mixed model; (2) mathematically, using an exponential relationship between BP and cross-sectional lumen area; and (3) using measured BP dependency of cfPWV derived from changes in BP induced by orthostatic changes (seated and supine) in a subset of subjects (n=17). The BP-independent effects of HR on cfPWV were quantified as 0.20 [0.11-0.28] m/s per 10 bpm (P<0.001, method 1), 0.16 [0.11-0.22] m/s per 10 bpm (P<0.001, method 2), and 0.16 [0.11-0.21] m/s per 10 bpm (P<0.001, method 3). With a mean HR dependency in the range of 0.16 to 0.20 m/s per 10 bpm, cfPWV may be considered to have minimal physiologically relevant changes for small changes in HR, but larger differences in HR must be considered as contributing to significant differences in cfPWV. © 2016 American Heart Association, Inc.

  16. Heart rate is a prognostic risk factor for myocardial infarction: a post hoc analysis in the PERFORM (Prevention of cerebrovascular and cardiovascular Events of ischemic origin with teRutroban in patients with a history oF ischemic strOke or tRansient ischeMic attack) study population.

    PubMed

    Fox, Kim; Bousser, Marie-Germaine; Amarenco, Pierre; Chamorro, Angel; Fisher, Marc; Ford, Ian; Hennerici, Michael G; Mattle, Heinrich P; Rothwell, Peter M

    2013-10-09

    Elevated resting heart rate is known to be detrimental to morbidity and mortality in cardiovascular disease, though its effect in patients with ischemic stroke is unclear. We analyzed the effect of baseline resting heart rate on myocardial infarction (MI) in patients with a recent noncardioembolic cerebral ischemic event participating in PERFORM. We compared fatal or nonfatal MI using adjusted Cox proportional hazards models for PERFORM patients with baseline heart rate <70 bpm (n=8178) or ≥70 bpm (n=10,802). In addition, heart rate was analyzed as a continuous variable. Other cerebrovascular and cardiovascular outcomes were also explored. Heart rate ≥70 bpm was associated with increased relative risk for fatal or nonfatal MI (HR 1.32, 95% CI 1.03-1.69, P=0.029). For every 5-bpm increase in heart rate, there was an increase in relative risk for fatal and nonfatal MI (11.3%, P=0.0002). Heart rate ≥70 bpm was also associated with increased relative risk for a composite of fatal or nonfatal ischemic stroke, fatal or nonfatal MI, or other vascular death (excluding hemorrhagic death) (P<0001); vascular death (P<0001); all-cause mortality (P<0001); and fatal or nonfatal stroke (P=0.04). For every 5-bpm increase in heart rate, there were increases in relative risk for fatal or nonfatal ischemic stroke, fatal or nonfatal MI, or other vascular death (4.7%, P<0.0001), vascular death (11.0%, P<0.0001), all-cause mortality (8.0%, P<0.0001), and fatal and nonfatal stroke (2.4%, P=0.057). Elevated heart rate ≥70 bpm places patients with a noncardioembolic cerebral ischemic event at increased risk for MI. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  17. Tannate complexes of antihistaminic drug: sustained release and taste masking approaches.

    PubMed

    Rahman, Ziyaur; Zidan, Ahmed S; Berendt, Robert T; Khan, Mansoor A

    2012-01-17

    The aim of this investigation was to evaluate the complexation potential of brompheniramine maleate (BPM) and tannic acid (TA) for sustained release and taste masking effects. The complexes (1:1-1:7 TA to BPM ratio) were prepared by the solvent evaporation method using methanol, phosphate buffer pH 6.8 or 0.1N HCl as common solvents. The complexes were characterized microscopically by scanning electron microscopy (SEM), chemically by Fourier transform infrared (FTIR) and solid-state NMR (SSNMR), thermally by differential scanning calorimetry (DSC), for crystallinity by powder X-ray powder diffraction (PXRD), for organoleptic evaluation by electronic tongue (e-tongue), and for solubility in 0.1N HCl and phosphate buffer pH 6.8. The dissolution studies were carried out using the USP II method at 50 rpm in 500 ml of dissolution media (0.1N HCl or phosphate buffer pH 6.8). SEM images revealed that the morphology of complexes were completely different from the individual components, and all complexes had the same morphological characteristics, irrespective of the solvent used for their preparation, pH or ratio of BPM and TA. The FTIR spectra showed the presence of chemical interactions between the TA and BPM. DSC, PXRD and SSNMR indicated that the drug lost its crystalline nature by formation of the complex. Complexation has significantly reduced the solubility of BPM and sustained the drug release up to 24h in phosphate buffer pH 6.8 media. The bitter taste of the BPM was completely masked which was indicated by Euclidean distance values which was far from the drug but near to its placebo in the complexes in all ratios studied. The taste masked complexes can be potentially developed as suitable dosage forms for pediatric use. In summary, complexation of BPM and TA effectively sustained the dissolution and masked the bitter taste of drug for the development of suitable dosage forms for pediatric use. Published by Elsevier B.V.

  18. Comparing the Effects of Rest and Massage on Return to Homeostasis Following Submaximal Aerobic Exercise: a Case Study

    PubMed Central

    Resnick, Portia B.

    2016-01-01

    Introduction Postexercise massage can be used to help promote recovery from exercise on the cellular level, as well as systemically by increasing parasympathetic activity. No studies to date have been done to assess the effects of massage on postexercise metabolic changes, including excess postexercise oxygen consumption (EPOC). The purpose of this study was to compare the effects of massage recovery and resting recovery on a subject’s heart rate variability and selected metabolic effects following a submaximal treadmill exercise session. Methods One healthy 24-year-old female subject performed 30 minutes of submaximal treadmill exercise prior to resting or massage recovery sessions. Metabolic data were collected throughout the exercise sessions and at three 10 minute intervals postexercise. Heart rate variability was evaluated for 10 minutes after each of two 30-minute recovery sessions, either resting or massage. Results Heart rate returned to below resting levels (73 bpm) with 30 and 60 minutes of massage recovery (72 bpm and 63 bpm, respectively) compared to 30 and 60 minutes of resting recovery (77 bpm and 74 bpm, respectively). Heart rate variability data showed a more immediate shift to the parasympathetic state following 30 minutes of massage (1.152 LF/HF ratio) versus the 30-minute resting recovery (6.91 LF/HF ratio). It took 60 minutes of resting recovery to reach similar heart rate variability levels (1.216 LF/HF) found after 30 minutes of massage. Ventilations after 30 minutes of massage recovery averaged 7.1 bpm compared to 17.9 bpm after 30 minutes of resting recovery. Conclusions No differences in EPOC were observed through either the resting or massage recovery based on the metabolic data collected. Massage was used to help the subject shift into parasympathetic activity more quickly than rest alone following a submaximal exercise session. PMID:26977215

  19. A wire scanner system for characterizing the BNL energy recovery LINAC beam position monitor system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Michnoff R.; Biscardi, C.; Cerniglia, P.

    2012-04-15

    A stepper motor controlled wire scanner system has recently been modified to support testing of the Brookhaven National Laboratory (BNL) Collider-Accelerator department's Energy Recovery Linac (ERL) beam position monitor (BPM) system. The ERL BPM consists of four 9.33 mm diameter buttons mounted at 90 degree spacing in a cube with 1.875 inch inside diameter. The buttons were designed by BNL and fabricated by Times Microwave Systems. Libera brilliance single pass BPM electronic modules with 700 MHz bandpass filter, manufactured by Instrumentation Technologies, will be used to measure the transverse beam positions at 14 locations around the ERL. The wire scannermore » assembly provides the ability to measure the BPM button response to a pulsed wire, and evaluate and calibrate the Libera position measurement electronics. A description of the wire scanner system and test result data will be presented.« less

  20. Democratizing Process Innovation? On Citizen Involvement in Public Sector BPM

    NASA Astrophysics Data System (ADS)

    Niehaves, Björn; Malsch, Robert

    ‘Open Innovation’ has been heavily discussed for product innovations; however, an information systems (IS) perspective on ‘process innovation’ has not yet been taken. Analyzing the example of the public sector in Germany, the paper seeks to investigate the factors that hinder and support ‘open process innovation’, a concept we define as the involvement of citizens in business process management (BPM) activities. With the help of a quantitative study (n=358), six factors are examined for their impact on citizen involvement in local government BPM initiatives. The results show that citizen involvement in reform processes is not primarily motivated by the aim of cost reduction, but rather related to legitimacy reasons and the intent to increase employee motivation. Based on these findings, implications for (design) theory and practice are discussed: Instead of detailed collaborative business processes modeling, the key of citizen involvement in public sector BPM lies in communication and mutual understanding.

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bahrdt, J.; Follath, R.; Frentrup, W.

    Reflections in synchrotron radiation beam lines tend to change the state of polarization of the radiation. This effect is more pronounced for steep angle of incidence, i.e. at low photon energy (say below 100 eV) beam lines. The APPLE II undulator UE112 at BESSY has all four magnetic rows shiftable and thus generates any state of polarization. To provide any intended polarization state at the sample we perform polarization measurements based on simple and fast linear polarization analysis that together with calculations of the undulator radiation predicts undulator settings that cancel beam line polarization effects.

  2. Light Optics for Optical Stochastic Cooling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Andorf, Matthew; Lebedev, Valeri; Piot, Philippe

    2016-06-01

    In Optical Stochastic Cooling (OSC) radiation generated by a particle in a "pickup" undulator is amplified and transported to a downstream "kicker" undulator where it interacts with the same particle which radiated it. Fermilab plans to carry out both passive (no optical amplifier) and active (optical amplifier) tests of OSC at the Integrable Optics Test Accelerator (IOTA) currently in construction*. The performace of the optical system is analyzed with simulations in Synchrotron Radiation Workshop (SRW) accounting for the specific temporal and spectral properties of undulator radiation and being augmented to include dispersion of lens material.

  3. The Advanced Light Source (ALS) Slicing Undulator Beamline

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Heimann, P. A.; Glover, T. E.; Plate, D.

    2007-01-19

    A beamline optimized for the bunch slicing technique has been construction at the Advanced Light Source (ALS). This beamline includes an in-vacuum undulator, soft and hard x-ray beamlines and a femtosecond laser system. The soft x-ray beamline may operate in spectrometer mode, where an entire absorption spectrum is accumulated at one time, or in monochromator mode. The femtosecond laser system has a high repetition rate of 20 kHz to improve the average slicing flux. The performance of the soft x-ray branch of the ALS slicing undulator beamline will be presented.

  4. Characterization of undulator radiation at the photon factory

    NASA Astrophysics Data System (ADS)

    Maezawa, Hideki; Suzuki, Yoshio; Kitamura, Hideo; Sasaki, Taizo

    1986-05-01

    Spectra of undulator radiation of the Photon Factory undulator, model PMU-2, were measured in a scale of absolute brightness in the soft X-ray region for various values of the K-parameter from 0.72 to 1.66. A significant reduction of the peak brightness was observed, whereas we also observed a relatively sharp edge at the high energy side of the first harmonic. The results show that the peak brightness and the band width are highly dependent on the beam parameters and the geometry of spectral observation.

  5. A compact high brightness laser synchrotron light source for medical applications

    NASA Astrophysics Data System (ADS)

    Nakajima, Kazuhisa

    1999-07-01

    The present high-brightness hard X-ray sources have been developed as third generation synchrotron light sources based on large high energy electron storage rings and magnetic undulators. Recently availability of compact terawatt lasers arouses a great interest in the use of lasers as undulators. The laser undulator concept makes it possible to construct an attractive compact synchrotron radiation source which has been proposed as a laser synchrotron light source. This paper proposes a compact laser synchrotron light source for mediacal applications, such as an intravenous coronary angiography and microbeam therapy.

  6. Optimization of pharmacotherapy in chronic heart failure: is heart rate adequately addressed?

    PubMed

    Franke, Jennifer; Wolter, Jan Sebastian; Meme, Lillian; Keppler, Jeannette; Tschierschke, Ramon; Katus, Hugo A; Zugck, Christian

    2013-01-01

    The aim of the study is to evaluate the use of beta-blockers in chronic heart failure (CHF) and the extent of heart rate reduction achieved in clinical practice and to determine differences in outcome of patients who fulfilled select inclusion criteria of the SHIFT study according to resting heart rate modulated by beta-blocker therapy. We evaluated an all-comer population of our dedicated CHF outpatient clinic between 2006 and 2010. For inclusion, individually optimized doses of guideline-recommended pharmacotherapy including beta-blockers had to be maintained for at least 3 months and routine follow-up performed at our outpatient CHF-clinic thereafter. Treatment dosages of beta-blockers, and demographic and clinical profiles including resting heart rate were assessed. The outcome of patients who fulfilled select inclusion criteria of the SHIFT study (left-ventricular ejection fraction (LVEF) ≤35 %, sinus rhythm, NYHA II-IV) and were followed-up for at least 1 year was stratified according to resting heart rates: ≥75 versus <75 bpm and ≥70 versus <70 bpm. The composite primary endpoint was defined as all-cause death or hospital admission for worsening heart failure during 12-month follow-up. In total, 3,181 patients were assessed in regard to treatment dosages of beta-blockers, and demographic and clinical profiles including resting heart rate. Of the overall studied population, 443 patients fulfilled all inclusion criteria and entered outcome analysis. Median observation time of survivors was 27.5 months with 1,039.7 observation-years in total. Up-titration to at least half the evidence-based target dose of beta-blockers was achieved in 69 % and full up-titration in 29 % of these patients. Patients with increased heart rates were younger, more often male, exhibited a higher NYHA functional class and lower LVEF. The primary endpoint occurred in 21 % of patients in the ≥70 bpm group versus 9 % of patients in the group with heart rates <70 bpm (p <0.01). Likewise, comparing the groups ≥75 and <75 bpm, the primary endpoint was significantly increased in the group of patients with heart rates ≥75 bpm 27 vs. 12.2 %; p < 0.01). 5-year event-free survival was significantly lower among patients with heart rates ≥70 bpm as compared to those with <70 bpm (log-rank test p < 0.05) and among patients in the ≥75 bpm group versus <75 bpm group (log-rank test p < 0.01). In conclusion, in clinical practice, 53 % of CHF patients have inadequate heart rate control (heart rates ≥75 bpm) despite concomitant beta-blocker therapy. In this non-randomized cohort, adequate heart rate control under individually optimized beta-blocker therapy was associated with improved mid- and long-term clinical outcome up to 5 years. As further up titration of beta-blockers is not achievable in many patients, the administration of a selective heart rate lowering agent, such as ivabradine adjuvant to beta-blockers may pose an opportunity to further modulate outcome.

  7. Metal-Organic Frameworks of Pyrazolate Derivatives: Synthesis and Applications for Chemical Sensing, Gas Separation, and Catalysis

    NASA Astrophysics Data System (ADS)

    Kivi, Charlie Eric William

    In this work we examine the structure and applications of metal-organic frameworks (MOFs) synthesized from pyrazolate derivatives. In total, six pyrazolate ligands were examined: 4-(4-(3,5-dimethyl-1H-pyrazol-4-yl)phenyl)pyridine (HL), 1,1'-methylenebis(3,5-dimethyl-1H-pyrazolyl-4-carboxylic acid) (H2BPM), triethyl-1,1',1''-methanetriyltris(3,5-dimethyl-1H-pyrazole-4-carboxylate) (TPM-1), triethyl-4,4',4''-(methanetriyltris[3,5-dimethyl-1H-pyrazole-1,4-diyl])tribenzoate (TPM-2), 1,1',1'',1'''-(propane-1,1,3,3-tetrayl)tetrakis(3,5-dimethyl-1H-pyrazole-4-carboxylic acid) (H4TPP), tetraethyl-1,1',1'',1'''-(1,4-phenylenebis[methanetriyl]) tetrakis(3,5-dimethyl-1H-pyrazole-4-carboxylate)pyridinephenylpyrazole ( TPX). These ligands were used to synthesize a variety of MOFs that were subsequently investigated for luminescent sensing, gas storage, and catalytic performance. In Chapter 2, three MOFs synthesized from the reaction of HL and CuX (X = Br, I) were investigated. These materials were found to form MOFs which contained the luminescent trinuclear Cu(I) pyrazolate unit. Only CuBr and HL alone resulted in a MOF of sufficient purity and stability to permit evaluation as a luminescent sensor. Experiments with various volatile organic compounds revealed turn-on (luminescence enhancement) behaviour for ethyl acetate, pentane, and benzene and turn-off (luminescence quenching) behaviour for diethyl ether and chloroform for this material. In Chapters 3 and 4, ten MOFs are described. These were synthesized from H2BPM and metal-acetate salts. Chapter 3 encompassed two MOFs: [Ni(BPM)]n·xDMSO and [Cd(BPM)]n·xDMSO. These MOFs are isostructural, microporous materials. Evacuation of the pores led to collapse of the [Cd(BPM)]n·xDMSO material but [Ni(BPM)]n·xDMSO proved to be permanently porous. Further investigations revealed [Ni(BPM)] n·xDMSO selectively adsorbed methane over nitrogen indicating it may serve as a porous material for coal mine methane capture. Chapter 4 investigated the many other structures H2BPM can assume in the presence of manganese, cobalt, iron, copper, and europium. Cobalt in particular proved highly tunable with 4 separate structures being synthesized such as [Co2(BPM)2(H2 O)4(Bpy)0.5]n·2DMF·2(H 2O). This was achieved through varying the synthetic conditions. [Co 2(BPM)2(H2O)4(Bpy) 0.5]n·2DMF·2(H2O)and [Eu( BPM)(OAc)]n were further investigated for the oxidation of olefins and luminescence respectively. In Chapter 5, metal complexes Mo(TPM-1)(CO)3, Mo(TPM-2)(CO)3, Pd2(H4TPP )Cl4, and Pd2(TPX)Cl4 were synthesized. The catalytic performance of Mo(TPM-1)(CO) 3 was evaluated and found to be effective for the oxidation of olefins. MOF synthesis was attempted with all four compounds but was ultimately unsuccessful. Although one MOF was produced from Mo(TPM-1)(CO)3, large scale synthesis was not possible preventing full investigation of its properties.

  8. Differential Resting-State Functional Connectivity of Striatal Subregions in Bipolar Depression and Hypomania

    PubMed Central

    Altinay, Murat I.; Hulvershorn, Leslie A.; Karne, Harish; Beall, Erik B.

    2016-01-01

    Abstract Bipolar disorder (BP) is characterized by periods of depression (BPD) and (hypo)mania (BPM), but the underlying state-related brain circuit abnormalities are not fully understood. Striatal functional activation and connectivity abnormalities have been noted in BP, but consistent findings have not been reported. To further elucidate striatal abnormalities in different BP states, this study investigated differences in resting-state functional connectivity of six striatal subregions in BPD, BPM, and healthy control (HC) subjects. Ninety medication-free subjects (30 BPD, 30 BPM, and 30 HC), closely matched for age and gender, were scanned using 3T functional magnetic resonance imaging (fMRI) acquired at resting state. Correlations of low-frequency blood oxygen level dependent signal fluctuations for six previously described striatal subregions were used to obtain connectivity maps of each subregion. Using a factorial design, main effects for differences between groups were obtained and post hoc pairwise group comparisons performed. BPD showed increased connectivity of the dorsal caudal putamen with somatosensory areas such as the insula and temporal gyrus. BPM group showed unique increased connectivity between left dorsal caudate and midbrain regions, as well as increased connectivity between ventral striatum inferior and thalamus. In addition, both BPD and BPM exhibited widespread functional connectivity abnormalities between striatal subregions and frontal cortices, limbic regions, and midbrain structures. In summary, BPD exhibited connectivity abnormalities of associative and somatosensory subregions of the putamen, while BPM exhibited connectivity abnormalities of associative and limbic caudate. Most other striatal subregion connectivity abnormalities were common to both groups and may be trait related. PMID:26824737

  9. Optics measurement and correction for the Relativistic Heavy Ion Collider

    NASA Astrophysics Data System (ADS)

    Shen, Xiaozhe

    The quality of beam optics is of great importance for the performance of a high energy accelerator like the Relativistic Heavy Ion Collider (RHIC). The turn-by-turn (TBT) beam position monitor (BPM) data can be used to derive beam optics. However, the accuracy of the derived beam optics is often limited by the performance and imperfections of instruments as well as measurement methods and conditions. Therefore, a robust and model-independent data analysis method is highly desired to extract noise-free information from TBT BPM data. As a robust signal-processing technique, an independent component analysis (ICA) algorithm called second order blind identification (SOBI) has been proven to be particularly efficient in extracting physical beam signals from TBT BPM data even in the presence of instrument's noise and error. We applied the SOBI ICA algorithm to RHIC during the 2013 polarized proton operation to extract accurate linear optics from TBT BPM data of AC dipole driven coherent beam oscillation. From the same data, a first systematic estimation of RHIC BPM noise performance was also obtained by the SOBI ICA algorithm, and showed a good agreement with the RHIC BPM configurations. Based on the accurate linear optics measurement, a beta-beat response matrix correction method and a scheme of using horizontal closed orbit bumps at sextupoles for arc beta-beat correction were successfully applied to reach a record-low beam optics error at RHIC. This thesis presents principles of the SOBI ICA algorithm and theory as well as experimental results of optics measurement and correction at RHIC.

  10. Preoperative risk assessment among women undergoing bilateral prophylactic mastectomy for cancer risk reduction.

    PubMed

    Rueth, Natasha M; McMahon, Melissa; Arrington, Amanda K; Swenson, Karen; Leach, Joseph; Tuttle, Todd M

    2011-09-01

    Cancer risk assessment is an important decision-making tool for women considering irreversible risk-reducing surgery. Our objective was to determine the prevalence of BRCA testing among women undergoing bilateral prophylactic mastectomy (BPM) and to review the characteristics of women who choose BPM within a metropolitan setting. We retrospectively reviewed records of women who underwent BPM in the absence of cancer within 2 health care systems that included 5 metropolitan hospitals. Women with invasive carcinoma or ductal carcinoma in situ (DCIS) were excluded; neither lobular carcinoma in situ (LCIS) nor atypical hyperplasia (AH) were exclusion criteria. We collected demographic information and preoperative screening and risk assessment, BRCA testing, reconstruction, and associated cancer risk-reducing surgery data. We compared women who underwent BRCA testing to those not tested. From January 2002 to July 2009, a total of 71 BPMs were performed. Only 25 women (35.2%) had preoperative BRCA testing; 88% had a BRCA mutation. Compared with tested women, BRCA nontested women were significantly older (39.1 vs. 49.2 years, P < 0.001), had significantly more preoperative biopsies and mammograms and had fewer previous or simultaneous cancer risk-reducing surgery (oophorectomy). Among BRCA nontested women, common indications for BPM were family history of breast cancer (n = 21, 45.6%) or LCIS or AH (n = 16, 34.8%); 9 nontested women (19.6%) chose BPM based on exclusively on cancer-risk anxiety or personal preference. Most women who underwent BPM did not receive preoperative genetic testing. Further studies are needed to corroborate our findings in other geographic regions and practice settings.

  11. Heart rate differentiates urgency and emergency in hypertensive crisis.

    PubMed

    Al Bannay, Rashed; Böhm, Michael; Husain, Aysha

    2013-08-01

    To study the clinical significance of presenting blood pressure parameters and heart rate in patients with hypertensive crisis. In patients admitted with hypertensive crisis between January 2011 and May 2011, demography, mode of presentation, co-morbidities, blood pressure readings, and heart rate at presentation were documented. Further clustering of hypertensive crisis into emergency or urgency was based on the presence or absence of target organ involvement. The relationship between blood pressure parameters, heart rate, and other variables was analyzed. 189 patients in sinus rhythm were enrolled in this pilot study. The rate of hypertensive urgency was 56 %, whereas the rate of hypertensive emergency was 44 %, respectively. Subjects with hypertensive emergency had a higher mean heart rate (93 ± 22.7 bpm) than those with urgency (81 ± 11.5 bpm) (P = 0.015). Women had higher heart rates (92 ± 18.5 bpm) than men (86 ± 17.6 bpm) (P = 0.014). Heart rates below 100 bpm had a specificity of 94 %, classifying patients as hypertensive urgency. Tachycardia had a powerful statistical association with hypertensive left ventricular failure (P < 0.0001). Other hemodynamic parameters, including systolic blood pressure, diastolic blood pressure, pulse pressure, and mean blood pressure relates neither to urgency nor to emergency. Diabetic patients with HBA1c levels of more than 53 mmol/mol had a heart rate of more than 100 bpm (P = 0.015) during hypertensive crisis. Normal heart rate is characteristic of hypertensive urgency. Tachycardia in this setting is an ominous sign and denotes hypertensive complications in particular left ventricular failure. Among diabetics, elevated heart rate is associated with poor glycemic control.

  12. Fourth Generation Light Sources

    NASA Astrophysics Data System (ADS)

    Winick, Herman

    1997-05-01

    Concepts and designs are now being developed at laboratories around the world for light sources with performance levels that exceed present sources, including the very powerful and successful third generation synchrotron radiation sources that have come on line in the past few years. Workshops (M. Cornacchia and H. Winick (eds), Workshop on Fourth Generation Light Sources, Feb. 24-27, 1992, SSRL Report 92/02) (J.-L. Laclare (ed), ICFA Workshop on Fourth Generation Light Sources, Jan. 22-25, 1996, ESRF Report) have been held to review directions for future sources. A main thrust is to increase the brightness and coherence of the radiation using storage rings with lower electron-beam emittance or free-electron lasers (FELs). In the infra-red part of the spectrum very high brightness and coherence is already provided by FEL user facilities driven by linacs and storage rings. It now appears possible to extend FEL operation to the VUV, soft X-ray and even hard X-ray spectral range, to wavelengths down to the angstrom range, using high energy linacs equipped with high-brightness rf photoinjectors and bunch-length compressors. R&D to develop such sources is in progress at BNL, DESY, KEK, SLAC and other laboratories. In the absence of mirrors to form optical cavities, short wavelengths are reached in FEL systems in which a high peak current, low-emittance electron beam becomes bunch-density modulated at the optical wavelength in a single pass through a long undulator by self-amplified spontaneous emission (SASE); i.e.; startup from noise. A proposal to use the last kilometer of the three kilometer SLAC linac (the first two kilometers will be used for injection to the PEP II B-Factory) to provide 15 GeV electron beams to reach 1.5 Angstroms by SASE in a 100 m long undulator is in preparation.

  13. Use of the BINP HLS to measure vertical changes in the locations of the building and ground at the PAL-XFEL

    NASA Astrophysics Data System (ADS)

    Choi, Hyo-Jin; Seo, Kwang-Won; Gil, Kye-Hwan; Kim, Seung-Hwan; Kang, Heung-Sik

    2016-09-01

    The Pohang Accelerator Laboratory's X-ray free-electron laser (PAL-XFEL), a 4 th generation light source, is currently being installed and will be completed by December 2015 so that users can be supported beginning in 2016. The PAL-XFEL equipment must continuously maintain the bunch-tobunch beam parameters (60 Hz, Energy: 10 GeV, Charge: 200 pC, Bunch Length: 60 fs, Emittance X/Y: 0.481/0.256 mm rad) in order to supply stable photons with the energy and flux appropriate for tests by beamline users. To this end, the PAL-XFEL equipment has to be kept precisely aligned (Linear Accelerator: +/- 100 μm, Undulator: +/- 50 μm). As a part of the process for installing the PAL-XFEL, a GPS-using surface geodetic network is being constructed for precise equipment measurement and alignment, and the installation of a tunnel measurement network inside the buildings is in the preparation stage; additionally, the fiducialization of major equipment is underway. After the PAL-XFEL equipment is optimized and aligned, if the ground and the buildings go through vertical changes during operation, misalignment (and tilt) of the equipment, including various magnets and RF structures, will cause errors in the electron beam's trajectory, which will lead to changes to the beam parameters. For continuous and systemic measurement of vertical changes in the buildings and monitoring of ground sinking and uplifting, the Budker Institute of Nuclear Physics (BINP) Ultrasonic-type Hydrostatic Levelling System (HLS) is to be installed and operated in all sections of the PAL-XFEL for the linear accelerator, the insertion device (undulator) and the beamline. This study will introduce the operation principle, design concept, and advantages (self-calibration) of the HLS and will outline its installation plan and operation plan.

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kesgin, Ibrahim; Kasa, Matthew; Ivanyushenkov, Yury

    Here, this paper presents test results on a prototype superconducting undulator magnet fabricated using 15% Zr-doped rare-earth barium copper oxide high temperature superconducting (HTS) tapes. On an 11-pole magnet we demonstrate an engineering current density, J e, of more than 2.1 kA mm -2 at 4.2 K, a value that is 40% higher than reached in comparable devices wound with NbTi-wire, which is used in all currently operating superconducting undulators. A novel winding scheme enabling the continuous winding of tape-shaped conductors into the intricate undulator magnets as well as a partial interlayer insulation procedure were essential in reaching this advancemore » in performance. Currently, there are rapid advances in the performance of HTS; therefore, achieving even higher current densities in an undulator structure or/and operating it at temperatures higher than 4.2 K will be possible, which would substantially simplify the cryogenic design and reduce overall costs.« less

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ivanyushenkov, Y.; Doose, C.; Fuerst, J.

    Development of superconducting undulator (SCU) technology continues at the Advanced Photon Source (APS). The experience of building and successful operating the first short-length, 16-mm period length superconducting undulator SCU0 paved the way for a 1-m long, 18-mm period device— SCU18-1— which has been in operation since May 2015. The APS SCU team has also built and tested a 1.5-m long, 21-mm period length undulator as a part of the LCLS SCU R&D program, aimed at demonstration of SCU technology availability for free electron lasers. This undulator successfully achieved all the requirements including a phase error of 5° RMS. Our teammore » has recently completed one more 1-m long, 18-mm period length undulator— SCU18-2— that is replacing the SCU0. We are also working on a helical SCU for the APS. The status of these projects will be presented.« less

  16. Experimental Investigation of Superradiance in a Tapered Free-Electron Laser Amplifier

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hidaka, Y.; She, Y.; Murphy, J.B.

    2011-03-28

    We report experimental studies of the effect of undulator tapering on superradiance in a single-pass high-gain free-electron laser (FEL) amplifier. The experiments were performed at the Source Development Laboratory (SDL) of National Synchrotron Light Source (NSLS). Efficiency was nearly tripled with tapering. Both the temporal and spectral properties of the superradiant FEL along the uniform and tapered undulator were experimentally characterized using frequency-resolved optical gating (FROG) images. Numerical studies predicted pulse broadening and spectral cleaning by undulator tapering Pulse broadening was experimentally verified. However, spectral cleanliness degraded with tapering. We have performed first experiments with a tapered undulator and amore » short seed laser pulse. Pulse broadening with tapering expected from simulations was experimentally confirmed. However, the experimentally obtained spectra degraded with tapering, whereas the simulations predicted improvement. A further numerical study is under way to resolve this issue.« less

  17. Wave-optics modeling of the optical-transport line for passive optical stochastic cooling

    NASA Astrophysics Data System (ADS)

    Andorf, M. B.; Lebedev, V. A.; Piot, P.; Ruan, J.

    2018-03-01

    Optical stochastic cooling (OSC) is expected to enable fast cooling of dense particle beams. Transition from microwave to optical frequencies enables an achievement of stochastic cooling rates which are orders of magnitude higher than ones achievable with the classical microwave based stochastic cooling systems. A subsystemcritical to the OSC scheme is the focusing optics used to image radiation from the upstream "pickup" undulator to the downstream "kicker" undulator. In this paper, we present simulation results using wave-optics calculation carried out with the SYNCHROTRON RADIATION WORKSHOP (SRW). Our simulations are performed in support to a proof-of-principle experiment planned at the Integrable Optics Test Accelerator (IOTA) at Fermilab. The calculations provide an estimate of the energy kick received by a 100-MeV electron as it propagates in the kicker undulator and interacts with the electromagnetic pulse it radiated at an earlier time while traveling through the pickup undulator.

  18. 3D theory of a high-gain free-electron laser based on a transverse gradient undulator

    NASA Astrophysics Data System (ADS)

    Baxevanis, Panagiotis; Ding, Yuantao; Huang, Zhirong; Ruth, Ronald

    2014-02-01

    The performance of a free-electron laser (FEL) depends significantly on the various parameters of the driving electron beam. In particular, a large energy spread in the beam results in a substantial reduction of the FEL gain, an effect which is especially relevant when one considers FELs driven by plasma accelerators or ultimate storage rings. For such cases, one possible solution is to use a transverse gradient undulator (TGU). In this concept, the energy spread problem is mitigated by properly dispersing the electron beam and introducing a linear, transverse field dependence in the undulator. This paper presents a self-consistent theoretical analysis of a TGU-based, high-gain FEL which takes into account three-dimensional (3D) effects, including beam size variations along the undulator. The results of our theory compare favorably with simulation and are used in fast optimization studies of various x-ray FEL configurations.

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Andorf, M. B.; Lebedev, V. A.; Piot, P.

    Optical stochastic cooling (OSC) is expected to enable fast cooling of dense particle beams. Transition from microwave to optical frequencies enables an achievement of stochastic cooling rates which are orders of magnitude higher than ones achievable with the classical microwave based stochastic cooling systems. A subsystemcritical to the OSC scheme is the focusing optics used to image radiation from the upstream “pickup” undulator to the downstream “kicker” undulator. In this paper, we present simulation results using wave-optics calculation carried out with the Synchrotron Radiation Workshop (SRW). Our simulations are performed in support to a proof-of-principle experiment planned at the Integrablemore » Optics Test Accelerator (IOTA) at Fermilab. The calculations provide an estimate of the energy kick received by a 100-MeV electron as it propagates in the kicker undulator and interacts with the electromagnetic pulse it radiated at an earlier time while traveling through the pickup undulator.« less

  20. Undulator performance on PEP storage ring with different optics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shenoy, G.K.; Viccaro, P.J.; Alp, E.E.

    1987-12-01

    Our ability to profitably utilize the radiation from undulators proposed for PEP is determined by their performance in the different operating modes and by whether the design tolerance required for acceptable operation of the device can be met with available technology. The purpose of this paper is to provide spectral characteristics for some typical devices calculated using a Monte-Carlo algorithm in which the Lienard-Wiechert potential is integrated over the trajectory of the charged particle along the undulator length. The actual emittance of the particle beam for the various PEP operating modes are included explicitly in the simulations. In addition, wemore » have carried out a single partial analysis of the effects of undulator magnetic field errors on the spectral properties in order to estimate the design tolerance requirements necessary for devices which have been proposed PEP. 6 figs.« less

  1. Radiation collimation in a thick crystalline undulator

    NASA Astrophysics Data System (ADS)

    Wistisen, Tobias Nyholm; Uggerhøj, Ulrik Ingerslev; Hansen, John Lundsgaard; Lauth, Werner; Klag, Pascal

    2017-05-01

    With the recent experimental confirmation of the existence of energetic radiation from a Small Amplitude, Small Period (SASP) crystalline undulator [T.N. Wistisen, K.K. Andersen, S. Yilmaz, R. Mikkelsen, J. Lundsgaard Hansen, U.I. Uggerhøj, W. Lauth, H. Backe, Phys. Rev. Lett. 112, 254801 (2014)], the field of specially manufactured crystals, from which specific radiation characteristics can be obtained, has evolved substantially. In this paper we confirm the existence of the crystalline undulator radiation, using electrons of energies of 855 GeV from the MAinzer MIcrotron (MAMI) in a crystal that is approximately 10 times thicker than the previous one. Furthermore, we have measured a significant increase in enhancement, in good agreement with calculations, of the undulator peak by collimation to angles smaller than the natural opening angle of the radiation emission process, 1 /γ. Contribution to the Topical Issue: "Dynamics of Systems at the Nanoscale", edited by Andrey Solov'yov and Andrei Korol.

  2. Volumetric PIV of multiple free-swimming maneuvers generated by the KnifeBot: a biomimetic vessel propelled by an undulating fin

    NASA Astrophysics Data System (ADS)

    Liu, Hanlin; Troolin, Daniel; Hortensius, Ruben; Pothos, Stamatios; Curet, Oscar

    2017-11-01

    An undulating fin represents a remarkable propulsion model for underwater vehicles due to its high propulsive efficiency and considerable locomotor capabilities. In this work, we used a bio-inspired vessel, the KnifeBot to demonstrate the maneuverability of undulating fin propulsion, including forward-backward swimming, station keeping and vertical swimming. This self-contained robotic system uses an undulating ventral fin as the propulsor and features a slender 3D-printed hull with 16 motors, 2 batteries and electronic boards encapsulated inside. We tested the robot in a water-filled tank and used volumetric particle image velocimetry (V3V PIV) to investigate the three-dimensional flow features and vortex structures generated by the undulating ribbon fin in free-swimming maneuvers. Our results indicate that in the forward swimming, a series of vortex tubes are shed off the fin edge. A streamwise jet at an oblique angle to the fin is generated in association with the vortex tubes propelling the robot forward as well as pitching it up. For the hovering maneuver with inward counter-propagating waves. The streamlines develop vertically downward with the tip vortex shed from the fin edge. This downward jet provides substantial heave force for the robot to swim upward or perform station keeping. Our findings will be useful for understanding the mechanical basis of undulating fin propulsion and facilitate the development of bio-inspired vehicles using undulatory propellers. Office of Naval Research under Award Number N00014-16-1-2505.

  3. Undulator-Based Laser Wakefield Accelerator Electron Beam Energy Spread and Emittance Diagnostic

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bakeman, M. S.; University of Nevada Reno, Reno, NV 89557; Van Tilborg, J.

    The design and current status of experiments to couple the Tapered Hybrid Undulator (THUNDER) to the Lawrence Berkeley National Laboratory (LBNL) laser plasma accelerator (LPA) to measure electron beam energy spread and emittance are presented.

  4. High Efficiency Electron-Laser Interactions in Tapered Helical Undulators

    NASA Astrophysics Data System (ADS)

    Duris, Joseph Patrick

    Efficient coupling of relativistic electron beams with high power radiation lies at the heart of advanced accelerator and light source research and development. The inverse free electron laser is a stable accelerator capable of harnessing very high intensity laser electric fields to efficiently transfer large powers from lasers to electron beams. In this dissertation, we first present the theoretical framework to describe the interaction, and then apply our improved understanding of the IFEL to the design and numerical study of meter-long, GeV IFELs for compact light sources. The central experimental work of the dissertation is the UCLA BNL helical inverse free electron laser experiment at the Accelerator Test Facility in Brookhaven National Laboratory which used a strongly tapered 54cm long, helical, permanent magnet undulator and a several hundred GW CO2 laser to accelerate electrons from 52 to 106MeV, setting new records for inverse free electron laser energy gain (54MeV) and average accelerating gradient (100MeV/m). The undulator design and fabrication as well as experimental diagnostics are presented. In order to improve the stability and quality of the accelerated electron beam, we redesigned the undulator for a slightly reduced output energy by modifying the magnet gap throughout the undulator, and we used this modified undulator to demonstrated capture of >25% of the injected beam without prebunching. In the study of heavily loaded GeV inverse free electron lasers, we show that a majority of the power may be transferred from a laser to the accelerated electron beam. Reversing the process to decelerate high power electron beams, a mechanism we refer to as tapering enhanced stimulated superradiant amplification, offers a clear path to high power light sources. We present studies of radiation production for a wide range of wavelengths (10mum, 13nm, and 0.3nm) using this method and discuss the design for a deceleration experiment using the same undulator used for acceleration in this experiment. By accounting for the evolving radiation field in the design of the undulator tapering, a large fraction of energy may be transferred between the electrons and laser, enabling compact, high-current GeV accelerators and various wavelength light-sources of unprecedented peak powers.

  5. The Tail of BPM

    NASA Astrophysics Data System (ADS)

    Kruba, Steve; Meyer, Jim

    Business process management suites (BPMS's) represent one of the fastest growing segments in the software industry as organizations automate their key business processes. As this market matures, it is interesting to compare it to Chris Anderson's 'Long Tail.' Although the 2004 "Long Tail" article in Wired magazine was primarily about the media and entertainment industries, it has since been applied (and perhaps misapplied) to other markets. Analysts describe a "Tail of BPM" market that is, perhaps, several times larger than the traditional BPMS product market. This paper will draw comparisons between the concepts in Anderson's article (and subsequent book) and the BPM solutions market.

  6. Coupled optics reconstruction from TBT data using MAD-X

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alexahin, Y.; Gianfelice-Wendt, E.; /Fermilab

    2007-06-01

    Turn-by-turn BPM data provide immediate information on the coupled optics functions at BPM locations. In the case of small deviations from the known (design) uncoupled optics some cognizance of the sources of perturbation, BPM calibration errors and tilts can also be inferred without detailed lattice modeling. In practical situations, however, fitting the lattice model with the help of some optics code would lead to more reliable results. We present an algorithm for coupled optics reconstruction from TBT data on the basis of MAD-X and give examples of its application for the Fermilab Tevatron accelerator.

  7. Performance Evaluation of LDPC Coding and Iterative Decoding System in BPM R/W Channel Affected by Head Field Gradient, Media SFD and Demagnetization Field

    NASA Astrophysics Data System (ADS)

    Nakamura, Yasuaki; Okamoto, Yoshihiro; Osawa, Hisashi; Aoi, Hajime; Muraoka, Hiroaki

    We evaluate the performance of the write-margin for the low-density parity-check (LDPC) coding and iterative decoding system in the bit-patterned media (BPM) R/W channel affected by the write-head field gradient, the media switching field distribution (SFD), the demagnetization field from adjacent islands and the island position deviation. It is clarified that the LDPC coding and iterative decoding system in R/W channel using BPM at 3 Tbit/inch2 has a write-margin of about 20%.

  8. Some Solved Problems with the SLAC PEP-II B-Factory Beam-Position Monitor System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, Ronald G.

    2000-05-05

    The Beam-Position Monitor (BPM) system for the SLAC PEP-II B-Factory has been in operation for over two years. Although the BPM system has met all of its specifications, several problems with the system have been identified and solved. The problems include errors and limitations in both the hardware and software. Solutions of such problems have led to improved performance and reliability. In this paper the authors report on this experience. The process of identifying problems is not at an end and they expect continued improvement of the BPM system.

  9. Modified coaxial wire method for measurement of transfer impedance of beam position monitors

    NASA Astrophysics Data System (ADS)

    Kumar, Mukesh; Babbar, L. K.; Deo, R. K.; Puntambekar, T. A.; Senecha, V. K.

    2018-05-01

    The transfer impedance is a very important parameter of a beam position monitor (BPM) which relates its output signal with the beam current. The coaxial wire method is a standard technique to measure transfer impedance of the BPM. The conventional coaxial wire method requires impedance matching between coaxial wire and external circuits (vector network analyzer and associated cables). This paper presents a modified coaxial wire method for bench measurement of the transfer impedance of capacitive pickups like button electrodes and shoe box BPMs. Unlike the conventional coaxial wire method, in the modified coaxial wire method no impedance matching elements have been used between the device under test and the external circuit. The effect of impedance mismatch has been solved mathematically and a new expression of transfer impedance has been derived. The proposed method is verified through simulation of a button electrode BPM using cst studio suite. The new method is also applied to measure transfer impedance of a button electrode BPM developed for insertion devices of Indus-2 and the results are also compared with its simulations. Close agreement between measured and simulation results suggests that the modified coaxial wire setup can be exploited for the measurement of transfer impedance of capacitive BPMs like button electrodes and shoe box BPM.

  10. Extracellular matrices for gastrointestinal surgery: Ex vivo testing and current applications

    PubMed Central

    Hoeppner, Jens; Marjanovic, Goran; Helwig, Peter; Hopt, Ulrich Theodor; Keck, Tobias

    2010-01-01

    AIM: To assess the effects of bile and pancreatic juice on structural and mechanical resistance of extracellular matrices (ECMs) in vitro. METHODS: Small-intestinal submucosa (SIS), porcine dermal matrix (PDM), porcine pericardial matrix (PPM) and bovine pericardial matrix (BPM) were incubated in human bile and pancreatic juice in vitro. ECMs were examined by macroscopic observation, scanning electron microscopy (SEM) and testing of mechanical resistance. RESULTS: PDM dissolved within 4 d after exposure to bile or pancreatic juice. SIS, PPM and PDM retained their integrity for > 60 d when incubated in either digestive juice. The effect of bile was found to be far more detrimental to mechanical stability than pancreatic juice in all tested materials. In SIS, the loss of mechanical stability after incubation in either of the digestive secretions was less distinct than in PPM and BPM [mFmax 4.01/14.27 N (SIS) vs 2.08/5.23 N (PPM) vs 1.48/7.89 N (BPM)]. In SIS, the extent of structural damage revealed by SEM was more evident in bile than in pancreatic juice. In PPM and BPM, structural damage was comparable in both media. CONCLUSION: PDM is less suitable for support of gastrointestinal healing. Besides SIS, PPM and BPM should also be evaluated experimentally for gastrointestinal indications. PMID:20731016

  11. Effect of varying heart rate on intra-ventricular filling fluid dynamics

    NASA Astrophysics Data System (ADS)

    Santhanakrishnan, Arvind; Okafor, Ikechukwu; Angirish, Yagna; Yoganathan, Ajit

    2013-11-01

    Impaired exercise tolerance is used to delineate asymptomatic patients during the clinical diagnosis of diastolic left heart failure. Examining the effects of varying heart rate on intra-ventricular filling can provide a physical understanding of the specific flow characteristics that are impacted during exercise. In this study, diastolic filling was investigated with an anatomical left ventricle (LV) physical model under normal heart rate of 70 bpm, and varying exercise conditions of 100 bpm and 120 bpm. The LV model was incorporated into a flow loop and tuned for physiological inflow rates and outflow pressures. 2D PIV measurements were conducted along 3 parallel longitudinal planes. The systemic pressure was maintained the same across all test conditions. The E/A ratio was maintained within 1.0-1.2 across all heart rates. The strength of the mitral vortex ring formed during E-wave, as well as the peak incoming jet velocity, decreased with increasing heart rate. During peak flow of the A-wave, the vortex ring propagated farther into the LV for 120 bpm as compared to 70 bpm. The results point to the heightened role of the atrial kick for optimal LV filling during exercise conditions. This study was funded by a grant from the National Heart, Lung and Blood Institute (RO1HL70262).

  12. Ligand effects on the structure and magnetic properties of alternating copper(II) chains with 2,2'-bipyrimidine- and polymethyl-substituted pyrazolates as bridging ligands.

    PubMed

    Castro, Isabel; Calatayud, M Luisa; Barros, Wdeson P; Carranza, José; Julve, Miguel; Lloret, Francesc; Marino, Nadia; De Munno, Giovanni

    2014-06-02

    A novel series of heteroleptic copper(II) compounds of formulas {[Cu2(μ-H2O)(μ-pz)2(μ-bpm)(ClO4)(H2O)]ClO4·2H2O}n (1), {[Cu2(μ-H2O)(μ-3-Mepz)2(μ-bpm)](ClO4)2·2H2O}n (2), and {[Cu2(μ-OH)(μ-3,5-Me2pz)(μ-bpm)(H-3,5-Me2pz)2](ClO4)2}n (3) [bpm = 2,2'-bipyrimidine, Hpz = pyrazole, H-3-Mepz = 3-methylpyrazole, and H-3,5-Me2pz = 3,5-dimethylpyrazole] have been synthesized and structurally characterized by X-ray diffraction methods. The crystal structures of 1 and 2 consist of copper(II) chains with regular alternating bpm and bis(pyrazolate)(aqua) bridges, whereas that of 3 is made up of copper(II) chains with regular alternating bpm and (pyrazolate)(hydroxo) bridges. The copper centers are six- (1) or five-coordinate (2) in axially elongated, octahedral (1) or square-pyramidal (2) environments in 1 and 2, whereas they are five-coordinate in distorted trigonal-bipyramidal surroundings in 3. The values of the copper-copper separations across the bpm/pyrazolate bridges are 5.5442(7)/3.3131(6) (1), 5.538(1)/3.235(1) (2), and 5.7673(7)/3.3220(6) Å (3). The magnetic properties of 1-3 have been investigated in the temperature range of 25-300 K. The analysis of their magnetic susceptibility data through the isotropic Hamiltonian for an alternating antiferromagnetic copper(II) chain model [H = -J∑i=1-n/2 (S2i·S2i-1 + αS2i·S2i+1), with α = J'/J and Si = SCu = 1/2] reveals the presence of a strong to moderate antiferromagnetic coupling through the bis(pyrazolate)(aqua) [-J = 217 (1) and 215 cm(-1) (2)] and (pyrazolate)(hydroxo) bridges [-J = 153 cm(-1) (3)], respectively, whereas a strong to weak antiferromagnetic coupling occurs through the bis-bidentate bpm [-J' = 211 (1), 213 (2), and 44 cm(-1) (3)]. A simple orbital analysis of the magnetic exchange interaction within the bpm- and pyrazolate-bridged dicopper(II) fragments of 1-3 visualizes the σ-type pathways involving the (dx(2)-y(2)) (1 and 2) or d(z(2)) (3) magnetic orbitals on each metal ion, which account for the variation of the magnetic properties in these three novel examples of one-dimensional copper(II) compounds with regular alternating intrachain antiferromagnetic interactions.

  13. Linear beam dynamics and ampere class superconducting RF cavities at RHIC

    NASA Astrophysics Data System (ADS)

    Calaga, Rama R.

    The Relativistic Heavy Ion Collider (RHIC) is a hadron collider designed to collide a range of ions from protons to gold. RHIC operations began in 2000 and has successfully completed five physics runs with several species including gold, deuteron, copper, and polarized protons. Linear optics and coupling are fundamental issues affecting the collider performance. Measurement and correction of optics and coupling are important to maximize the luminosity and sustain stable operation. A numerical approach, first developed at SLAC, was implemented to measure linear optics from coherent betatron oscillations generated by ac dipoles and recorded at multiple beam position monitors (BPMs) distributed around the collider. The approach is extended to a fully coupled 2D case and equivalence relationships between Hamiltonian and matrix formalisms are derived. Detailed measurements of the transverse coupling terms are carried out at RHIC and correction strategies are applied to compensate coupling both locally and globally. A statistical approach to determine BPM reliability and performance over the past three runs and future improvements also discussed. Aiming at a ten-fold increase in the average heavy-ion luminosity, electron cooling is the enabling technology for the next luminosity upgrade (RHIC II). Cooling gold ion beams at 100 GeV/nucleon requires an electron beam of approximately 54 MeV and a high average current in the range of 50-200 mA. All existing e-Coolers are based on low energy DC accelerators. The only viable option to generate high current, high energy, low emittance CW electron beam is through a superconducting energy-recovery linac (SC-ERL). In this option, an electron beam from a superconducting injector gun is accelerated using a high gradient (˜ 20 MV/m) superconducting RF (SRF) cavity. The electrons are returned back to the cavity with a 180° phase shift to recover the energy back into the cavity before being dumped. A design and development of a half-cell electron gun and a five-cell SRF linac cavity are presented. Several RF and beam dynamics issues ultimately resulting in an optimum cavity design are discussed in detail.

  14. Variable-Period Undulators For Synchrotron Radiation

    DOEpatents

    Shenoy, Gopal; Lewellen, John; Shu, Deming; Vinokurov, Nikolai

    2005-02-22

    A new and improved undulator design is provided that enables a variable period length for the production of synchrotron radiation from both medium-energy and high-energy storage rings. The variable period length is achieved using a staggered array of pole pieces made up of high permeability material, permanent magnet material, or an electromagnetic structure. The pole pieces are separated by a variable width space. The sum of the variable width space and the pole width would therefore define the period of the undulator. Features and advantages of the invention include broad photon energy tunability, constant power operation and constant brilliance operation.

  15. Micropole Undulators In Synchrotron Radiation Technology: Design And Construction Of A Submillimeter Period Prototype With A 3 Kilogauss Peak Field At SSRL

    NASA Astrophysics Data System (ADS)

    Tatchyn, Roman; Csonka, Paul

    1986-01-01

    The availability of undulators with submillimeter periods will profoundly affect the future development of soft x-ray sources and their attendant instrumentation. Outputs comparable to those of present-day conventional undulators, obtainable with much lower energy storage rings, is only one promising aspect of such devices. This paper critically examines some of the future prospects of such devices and describes the design and practical construction of a 1" long prototype consisting of 35 periods. A proposed experiment to test this device on a linac is described.

  16. Strong permanent magnet-assisted electromagnetic undulator

    DOEpatents

    Halbach, Klaus

    1988-01-01

    This invention discloses an improved undulator comprising a plurality of electromagnet poles located along opposite sides of a particle beam axis with alternate north and south poles on each side of the beam to cause the beam to wiggle or undulate as it travels generally along the beam axis and permanent magnets spaced adjacent the electromagnetic poles on each side of the axis of said particle beam in an orientation sufficient to reduce the saturation of the electromagnet poles whereby the field strength of the electromagnet poles can be increased beyond the normal saturation levels of the electromagnetic poles.

  17. A strong permanent magnet-assisted electromagnetic undulator

    DOEpatents

    Halbach, K.

    1987-01-30

    This invention discloses an improved undulator comprising a plurality of electromagnet poles located along opposite sides of a particle beam axis with alternate north and south poles on each side of the beam to cause the beam to wiggle or undulate as it travels generally along the beam axis and permanent magnets spaced adjacent the electromagnetic poles on each side of the axis of said particle beam in an orientation sufficient to reduce the saturation of the electromagnet poles whereby the field strength of the electromagnet poles can be increased beyond the normal saturation levels of the electromagnetic poles. 4 figs.

  18. High Efficiency Energy Extraction from a Relativistic Electron Beam in a Strongly Tapered Undulator

    DOE PAGES

    Sudar, N.; Musumeci, P.; Duris, J.; ...

    2016-10-19

    Here we present results of an experiment where, using a 200 GW CO 2 laser seed, a 65 MeV electron beam was decelerated down to 35 MeV in a 54-cm-long strongly tapered helical magnetic undulator, extracting over 30% of the initial electron beam energy to coherent radiation. These results, supported by simulations of the radiation field evolution, demonstrate unparalleled electro-optical conversion efficiencies for a relativistic beam in an undulator field and represent an important step in the development of high peak and average power coherent radiation sources.

  19. Progress on the superconducting undulator for ANKA and on the instrumentation for R and D

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Casalbuoni, Sara; Baumbach, Tilo; Grau, Andreas

    2010-06-23

    Superconducting undulators show a larger magnetic field strength for the same gap and period length, as compared to permanent magnet devices, which allows to generate X-ray beams of higher brilliance and with harder spectrum. The worldwide first short period length superconducting undulator is in operation since 2005 at the synchrotron light source ANKA in Karlsruhe [1]. To further drive the development in this field a research and development program is being carried out. In this contribution we report on the last progress of the construction of a 1.5 m long superconducting undulator with a period length of 15 mm, plannedmore » to be installed in ANKA beginning 2010 to be the light source of the new beamline NANO for high resolution X-ray scattering. The key specifications of the system are an undulator parameter K higher than 2 (with a magnetic gap of 5 mm) and a phase error smaller than 3.5 degrees. Cryocoolers will keep the coils at 4.2 K for a beam heat load of 4 W. The ongoing R and D includes improvements in understanding of the magnetic field properties and of the beam heat load mechanisms. The tools and instruments under development to fulfill these tasks are also discussed.« less

  20. Progress on the superconducting undulator for ANKA and on the instrumentation for R&D

    NASA Astrophysics Data System (ADS)

    Casalbuoni, Sara; Baumbach, Tilo; Grau, Andreas; Hagelstein, Michael; de Jauregui, David Saez; Boffo, Cristian; Borlein, Markus; Walter, Wolfgang; Magerl, Andreas; Mashkina, Elena; Vassiljev, Nikita

    2010-06-01

    Superconducting undulators show a larger magnetic field strength for the same gap and period length, as compared to permanent magnet devices, which allows to generate X-ray beams of higher brilliance and with harder spectrum. The worldwide first short period length superconducting undulator is in operation since 2005 at the synchrotron light source ANKA in Karlsruhe [1]. To further drive the development in this field a research and development program is being carried out. In this contribution we report on the last progress of the construction of a 1.5 m long superconducting undulator with a period length of 15 mm, planned to be installed in ANKA beginning 2010 to be the light source of the new beamline NANO for high resolution X-ray scattering. The key specifications of the system are an undulator parameter K higher than 2 (with a magnetic gap of 5 mm) and a phase error smaller than 3.5 degrees. Cryocoolers will keep the coils at 4.2 K for a beam heat load of 4 W. The ongoing R&D includes improvements in understanding of the magnetic field properties and of the beam heat load mechanisms. The tools and instruments under development to fulfill these tasks are also discussed.

  1. Spatial uncertainty of a geoid undulation model in Guayaquil, Ecuador

    NASA Astrophysics Data System (ADS)

    Chicaiza, E. G.; Leiva, C. A.; Arranz, J. J.; Buenańo, X. E.

    2017-06-01

    Geostatistics is a discipline that deals with the statistical analysis of regionalized variables. In this case study, geostatistics is used to estimate geoid undulation in the rural area of Guayaquil town in Ecuador. The geostatistical approach was chosen because the estimation error of prediction map is getting. Open source statistical software R and mainly geoR, gstat and RGeostats libraries were used. Exploratory data analysis (EDA), trend and structural analysis were carried out. An automatic model fitting by Iterative Least Squares and other fitting procedures were employed to fit the variogram. Finally, Kriging using gravity anomaly of Bouguer as external drift and Universal Kriging were used to get a detailed map of geoid undulation. The estimation uncertainty was reached in the interval [-0.5; +0.5] m for errors and a maximum estimation standard deviation of 2 mm in relation with the method of interpolation applied. The error distribution of the geoid undulation map obtained in this study provides a better result than Earth gravitational models publicly available for the study area according the comparison with independent validation points. The main goal of this paper is to confirm the feasibility to use geoid undulations from Global Navigation Satellite Systems and leveling field measurements and geostatistical techniques methods in order to use them in high-accuracy engineering projects.

  2. The correlation between fetal bradycardia area in the second stage of labor and acidemia at birth.

    PubMed

    Tranquilli, Andrea L; Biagini, Alessandra; Greco, Pantaleo; Di Tommaso, Mariarosaria; Giannubilo, Stefano R

    2013-09-01

    To quantify fetal bradycardia in the second stage of labor and to determine the threshold of the area that correlates with neonatal acidemia. We analyzed the cardiotocograms of 33 women with single pregnancy and term spontaneous labor who presented fetal bradycardia in the second stage of labor. We retrospectively calculated the fetal bradycardia area in the last 60 min before delivery with an upper limit of 90 bpm and correlated the area with neonatal pH. The study of the regression line determined the cut-off threshold between fetal well-being and distress. Significance was set at p < 0.05. The linear correlation between the bradycardia area and neonatal pH indicate that increasing bradycardia area was correlated with significant pH decrease. The threshold value of the area indicative of severe acidemia was ≥ 12.72 cm(2) (Pearson r = -0.76, p < 0.002). The diagnostic accuracy of the test was 73%. The PPV = 78.5% and the NPV = 68.4%. With such a cut-off, the timing of acidemia can be calculated as 25 min for a fetal heart rate (FHR) of 80 bpm, 13 min for a FHR of 70 bpm, 8 min for a FHR of 60 bpm, 6 min for a FHR of 50 bpm and 5 min for a FHR of 40 bpm. The bradycardia area in the second stage of labor significantly correlates with an accurate timing of fetal acidemia. Regardless of the cause of the bradycardia, the time for intervention is often short, meaning that any available intervention may be ineffective in preventing acidemia or even injury.

  3. Dopamine depletion attenuates some behavioral abnormalities in a hyperdopaminergic mouse model of bipolar disorder

    PubMed Central

    van Enkhuizen, Jordy; Geyer, Mark A.; Halberstadt, Adam L.; Zhuang, Xiaoxi; Young, Jared W.

    2014-01-01

    Background Patients with BD suffer from multifaceted symptoms, including hyperactive and psychomotor agitated behaviors. Previously, we quantified hyperactivity, increased exploration, and straighter movements of patients with BD mania in the human Behavioral Pattern Monitor (BPM). A similar BPM profile is observed in mice that are hyperdopaminergic due to reduced dopamine transporter (DAT) functioning. We hypothesized that dopamine depletion through alpha-methyl-p-tyrosine (AMPT) administration would attenuate this mania-like profile. Methods Male and female DAT wild-type (WT; n=26) and knockdown (KD; n=28) mice on a C57BL/6 background were repeatedly tested in the BPM to assess profile robustness and stability. The optimal AMPT dose was identified by treating male C57BL/6 mice (n=39) with vehicle or AMPT (10, 30, or 100 mg/kg) at 24, 20, and 4 h prior to testing in the BPM. Then, male and female DAT WT (n=40) and KD (n=37) mice were tested in the BPM after vehicle or AMPT (30 mg/kg) treatment. Results Compared to WT littermates, KD mice exhibited increased activity, exploration, straighter movement, and disorganized behavior. AMPT-treatment reduced hyperactivity and increased path organization, but potentiated specific exploration in KD mice without affecting WT mice. Limitations AMPT is not specific to dopamine and also depletes norepinephrine. Conclusions KD mice exhibit abnormal exploration in the BPM similar to patients with BD mania. AMPT-induced dopamine depletion attenuated some, but potentiated other, aspects of this mania-like profile in mice. Future studies should extend these findings into other aspects of mania to determine the suitability of AMPT as a treatment for BD mania. PMID:24287168

  4. BPM-CUL3 E3 ligase modulates thermotolerance by facilitating negative regulatory domain-mediated degradation of DREB2A in Arabidopsis.

    PubMed

    Morimoto, Kyoko; Ohama, Naohiko; Kidokoro, Satoshi; Mizoi, Junya; Takahashi, Fuminori; Todaka, Daisuke; Mogami, Junro; Sato, Hikaru; Qin, Feng; Kim, June-Sik; Fukao, Yoichiro; Fujiwara, Masayuki; Shinozaki, Kazuo; Yamaguchi-Shinozaki, Kazuko

    2017-10-03

    DEHYDRATION-RESPONSIVE ELEMENT BINDING PROTEIN 2A (DREB2A) acts as a key transcription factor in both drought and heat stress tolerance in Arabidopsis and induces the expression of many drought- and heat stress-inducible genes. Although DREB2A expression itself is induced by stress, the posttranslational regulation of DREB2A, including protein stabilization, is required for its transcriptional activity. The deletion of a 30-aa central region of DREB2A known as the negative regulatory domain (NRD) transforms DREB2A into a stable and constitutively active form referred to as DREB2A CA. However, the molecular basis of this stabilization and activation has remained unknown for a decade. Here we identified BTB/POZ AND MATH DOMAIN proteins (BPMs), substrate adaptors of the Cullin3 (CUL3)-based E3 ligase, as DREB2A-interacting proteins. We observed that DREB2A and BPMs interact in the nuclei, and that the NRD of DREB2A is sufficient for its interaction with BPMs. BPM -knockdown plants exhibited increased DREB2A accumulation and induction of DREB2A target genes under heat and drought stress conditions. Genetic analysis indicated that the depletion of BPM expression conferred enhanced thermotolerance via DREB2A stabilization. Thus, the BPM-CUL3 E3 ligase is likely the long-sought factor responsible for NRD-dependent DREB2A degradation. Through the negative regulation of DREB2A stability, BPMs modulate the heat stress response and prevent an adverse effect of excess DREB2A on plant growth. Furthermore, we found the BPM recognition motif in various transcription factors, implying a general contribution of BPM-mediated proteolysis to divergent cellular responses via an accelerated turnover of transcription factors.

  5. Heart rate and use of beta-blockers in stable outpatients with coronary artery disease.

    PubMed

    Steg, Ph Gabriel; Ferrari, Roberto; Ford, Ian; Greenlaw, Nicola; Tardif, Jean-Claude; Tendera, Michal; Abergel, Hélène; Fox, Kim M

    2012-01-01

    Heart rate (HR) is an emerging risk factor in coronary artery disease (CAD). However, there is little contemporary data regarding HR and the use of HR-lowering medications, particularly beta-blockers, among patients with stable CAD in routine clinical practice. The goal of the present analysis was to describe HR in such patients, overall and in relation to beta-blocker use, and to describe the determinants of HR. CLARIFY is an international, prospective, observational, longitudinal registry of outpatients with stable CAD, defined as prior myocardial infarction or revascularization procedure, evidence of coronary stenosis of >50%, or chest pain associated with proven myocardial ischemia. A total of 33,438 patients from 45 countries in Europe, the Americas, Africa, Middle East, and Asia/Pacific were enrolled between November 2009 and July 2010. Most of the 33,177 patients included in this analysis were men (77.5%). Mean (SD) age was 64.2 (10.5) years, HR by pulse was 68.3 (10.6) bpm, and by electrocardiogram was 67.2 (11.4) bpm. Overall, 44.0% had HR ≥ 70 bpm. Beta-blockers were used in 75.1% of patients and another 14.4% had intolerance or contraindications to beta-blocker therapy. Among 24,910 patients on beta-blockers, 41.1% had HR ≥ 70 bpm. HR ≥ 70 bpm was independently associated with higher prevalence and severity of angina, more frequent evidence of myocardial ischemia, and lack of use of HR-lowering agents. Despite a high rate of use of beta-blockers, stable CAD patients often have resting HR ≥ 70 bpm, which was associated with an overall worse health status, more frequent angina and ischemia. Further HR lowering is possible in many patients with CAD. Whether it will improve symptoms and outcomes is being tested.

  6. Automatic exposure control at single- and dual-heartbeat CTCA on a 320-MDCT volume scanner: effect of heart rate, exposure phase window setting, and reconstruction algorithm.

    PubMed

    Funama, Yoshinori; Utsunomiya, Daisuke; Taguchi, Katsuyuki; Oda, Seitaro; Shimonobo, Toshiaki; Yamashita, Yasuyuki

    2014-05-01

    To investigate whether electrocardiogram (ECG)-gated single- and dual-heartbeat computed tomography coronary angiography (CTCA) with automatic exposure control (AEC) yields images with uniform image noise at reduced radiation doses. Using an anthropomorphic chest CT phantom we performed prospectively ECG-gated single- and dual-heartbeat CTCA on a second-generation 320-multidetector CT volume scanner. The exposure phase window was set at 75%, 70-80%, 40-80%, and 0-100% and the heart rate at 60 or 80 or corr80 bpm; images were reconstructed with filtered back projection (FBP) or iterative reconstruction (IR, adaptive iterative dose reduction 3D). We applied AEC and set the image noise level to 20 or 25 HU. For each technique we determined the image noise and the radiation dose to the phantom center. With half-scan reconstruction at 60 bpm, a 70-80% phase window- and a 20-HU standard deviation (SD) setting, the imagenoise level and -variation along the z axis manifested similar curves with FBP and IR. With half-scan reconstruction, the radiation dose to the phantom center with 70-80% phase window was 18.89 and 12.34 mGy for FBP and 4.61 and 3.10 mGy for IR at an SD setting SD of 20 and 25 HU, respectively. At 80 bpm with two-segment reconstruction the dose was approximately twice that of 60 bpm at both SD settings. However, increasing radiation dose at corr80 bpm was suppressed to 1.39 times compared to 60 bpm. AEC at ECG-gated single- and dual-heartbeat CTCA controls the image noise at different radiation dose. Copyright © 2013 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  7. Body image issues after bilateral prophylactic mastectomy with breast reconstruction in healthy women at risk for hereditary breast cancer.

    PubMed

    Gopie, Jessica P; Mureau, Marc A M; Seynaeve, Caroline; Ter Kuile, Moniek M; Menke-Pluymers, Marian B E; Timman, Reinier; Tibben, Aad

    2013-09-01

    The outcome of bilateral prophylactic mastectomy with breast reconstruction (BPM-IBR) in healthy BRCA1/2 mutation carriers can be potentially burdensome for body image and the intimate relationship. Therefore, in the current analysis the impact on body image, sexual and partner relationship satisfaction was prospectively investigated in women opting for BPM-IBR as well as cancer distress and general quality of life. Healthy women undergoing BPM-IBR completed questionnaires preoperatively (T0, n = 48), at 6 months (T1, n = 44) and after finishing breast reconstruction (median 21 months, range 12-35) (T2, n = 36). With multi-level regression analyses the course of outcome variables was investigated and a statistically significant change in body image and/or sexual and partner relationship satisfaction was predicted by baseline covariates. Body image significantly decreased at T1. At T2 sexual relationship satisfaction and body image tended to be lower compared to baseline. The overall partner relationship satisfaction did not significantly change. At T2, 37 % of the women reported that their breasts felt unpleasantly, 29 % was not satisfied with their breast appearance and 21 % felt embarrassed for their naked body. Most body image issues remained unchanged in 30 % of the women. A negative body image was predicted by high preoperative cancer distress. BPM-IBR was associated with adverse impact on body image in a substantial subgroup, but satisfaction with the overall sexual and partner relationship did not significantly change in time. The psychosocial impact of BPM-IBR in unaffected women should not be underestimated. Psychological support should ideally be integrated both before and after BPM-IBR.

  8. Effects of various mouthpieces on respiratory physiology during steady-state exercise in college-aged subjects.

    PubMed

    Garner, Dena P

    2015-01-01

    Protective mouthpieces have been used in a variety of sports to decrease the risk of orofacial injury. There are limited data to suggest that mouthpiece use during exercise may also provide an ergogenic effect. The aim of the present study was to investigate the effects of 3 different mouthpiece designs-boil-and-bite (BB) mouthpiece, ethylene vinyl acetate (EVA) custom mandibular mouthpiece, and polypropylene (Poly) custom mandibular mouthpiece-on respiratory physiology parameters and compare them with results of a no-mouthpiece (NM) condition. Sixteen college-aged, recreationally fit subjects ran for 10 minutes in 4 separate trials; mouthpiece conditions were randomly assigned to each trial for all subjects. Respiratory and cardiorespiratory measures, including oxygen uptake, carbon dioxide exhalation, ventilation, heart rate, tidal volume, and respiratory rate (RR), were assessed throughout testing. A repeated-measures analysis of variance indicated that RR was significantly lower (P = 0.04) in the BB mouthpiece condition (27.92 breaths per minute [BPM]) than in the NM condition (30.63 BPM). In paired t tests between conditions, the RR demonstrated in the BB condition (27.92 BPM) was significantly lower (P = 0.04) than that of each other condition (NM, 30.63 BPM; EVA, 29.92 BPM; and Poly, 29.92 BPM). The outcomes of the present study demonstrate that the use of the BB mouthpiece decreased RR during exercise. The differences cited between conditions may be attributed to the design of the mouthpiece and its mandibular placement as well as the activity of the genioglossus muscle. However, future studies should assess these parameters to determine the plausibility of these theories.

  9. Triggering for Magnetic Field Measurements of the LCLS Undulators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hacker, Kirsten

    A triggering system for magnetic field measurements of the LCLS undulators has been built with a National Instruments PXI-1002 and a Xylinx FPGA board. The system generates single triggers at specified positions, regardless of encoder sensor jitter about a linear scale.

  10. Assembly and analysis of a male sterile rubber tree mitochondrial genome reveals DNA rearrangement events and a novel transcript.

    PubMed

    Shearman, Jeremy R; Sangsrakru, Duangjai; Ruang-Areerate, Panthita; Sonthirod, Chutima; Uthaipaisanwong, Pichahpuk; Yoocha, Thippawan; Poopear, Supannee; Theerawattanasuk, Kanikar; Tragoonrung, Somvong; Tangphatsornruang, Sithichoke

    2014-02-10

    The rubber tree, Hevea brasiliensis, is an important plant species that is commercially grown to produce latex rubber in many countries. The rubber tree variety BPM 24 exhibits cytoplasmic male sterility, inherited from the variety GT 1. We constructed the rubber tree mitochondrial genome of a cytoplasmic male sterile variety, BPM 24, using 454 sequencing, including 8 kb paired-end libraries, plus Illumina paired-end sequencing. We annotated this mitochondrial genome with the aid of Illumina RNA-seq data and performed comparative analysis. We then compared the sequence of BPM 24 to the contigs of the published rubber tree, variety RRIM 600, and identified a rearrangement that is unique to BPM 24 resulting in a novel transcript containing a portion of atp9. The novel transcript is consistent with changes that cause cytoplasmic male sterility through a slight reduction to ATP production efficiency. The exhaustive nature of the search rules out alternative causes and supports previous findings of novel transcripts causing cytoplasmic male sterility.

  11. Analytical N beam position monitor method

    NASA Astrophysics Data System (ADS)

    Wegscheider, A.; Langner, A.; Tomás, R.; Franchi, A.

    2017-11-01

    Measurement and correction of focusing errors is of great importance for performance and machine protection of circular accelerators. Furthermore LHC needs to provide equal luminosities to the experiments ATLAS and CMS. High demands are also set on the speed of the optics commissioning, as the foreseen operation with β*-leveling on luminosity will require many operational optics. A fast measurement of the β -function around a storage ring is usually done by using the measured phase advance between three consecutive beam position monitors (BPMs). A recent extension of this established technique, called the N-BPM method, was successfully applied for optics measurements at CERN, ALBA, and ESRF. We present here an improved algorithm that uses analytical calculations for both random and systematic errors and takes into account the presence of quadrupole, sextupole, and BPM misalignments, in addition to quadrupolar field errors. This new scheme, called the analytical N-BPM method, is much faster, further improves the measurement accuracy, and is applicable to very pushed beam optics where the existing numerical N-BPM method tends to fail.

  12. High Resolution BPM for Linear Colliders

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Simon, C.; Chel, S.; Luong, M.

    2006-11-20

    A high resolution Beam Position Monitor (BPM) is necessary for the beam-based alignment systems of high energy and low emittance electron linacs. Such a monitor is developed in the framework of the European CARE/SRF programme, in a close collaboration between DESY and CEA/DSM/DAPNIA. This monitor is a radiofrequency re-entrant cavity, which can be used either at room or cryogenic temperature, in an environment where dust particle contamination has to be avoided, such as superconducting cavities in a cryomodule. A first prototype of a re-entrant BPM has already delivered measurements at 2K. inside the first cryomodule (ACC1) on the TESLA Testmore » Facility 2 (TTF2). The performances of this BPM are analyzed both experimentally and theoretically, and the limitations of this existing system clearly identified. A new cavity and new electronics have been designed in order to improve the position resolution down to 1 {mu}m and the damping time down to 10 ns.« less

  13. Digital signal processing the Tevatron BPM signals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cancelo, G.; James, E.; Wolbers, S.

    2005-05-01

    The Beam Position Monitor (TeV BPM) readout system at Fermilab's Tevatron has been updated and is currently being commissioned. The new BPMs use new analog and digital hardware to achieve better beam position measurement resolution. The new system reads signals from both ends of the existing directional stripline pickups to provide simultaneous proton and antiproton measurements. The signals provided by the two ends of the BPM pickups are processed by analog band-pass filters and sampled by 14-bit ADCs at 74.3MHz. A crucial part of this work has been the design of digital filters that process the signal. This paper describesmore » the digital processing and estimation techniques used to optimize the beam position measurement. The BPM electronics must operate in narrow-band and wide-band modes to enable measurements of closed-orbit and turn-by-turn positions. The filtering and timing conditions of the signals are tuned accordingly for the operational modes. The analysis and the optimized result for each mode are presented.« less

  14. MEthods of ASsessing blood pressUre: identifying thReshold and target valuEs (MeasureBP): a review & study protocol.

    PubMed

    Blom, Kimberly C; Farina, Sasha; Gomez, Yessica-Haydee; Campbell, Norm R C; Hemmelgarn, Brenda R; Cloutier, Lyne; McKay, Donald W; Dawes, Martin; Tobe, Sheldon W; Bolli, Peter; Gelfer, Mark; McLean, Donna; Bartlett, Gillian; Joseph, Lawrence; Featherstone, Robin; Schiffrin, Ernesto L; Daskalopoulou, Stella S

    2015-04-01

    Despite progress in automated blood pressure measurement (BPM) technology, there is limited research linking hard outcomes to automated office BPM (OBPM) treatment targets and thresholds. Equivalences for automated BPM devices have been estimated from approximations of standardized manual measurements of 140/90 mmHg. Until outcome-driven targets and thresholds become available for automated measurement methods, deriving evidence-based equivalences between automated methods and standardized manual OBPM is the next best solution. The MeasureBP study group was initiated by the Canadian Hypertension Education Program to close this critical knowledge gap. MeasureBP aims to define evidence-based equivalent values between standardized manual OBPM and automated BPM methods by synthesizing available evidence using a systematic review and individual subject-level data meta-analyses. This manuscript provides a review of the literature and MeasureBP study protocol. These results will lay the evidenced-based foundation to resolve uncertainties within blood pressure guidelines which, in turn, will improve the management of hypertension.

  15. Ventricular fibrillation occurring after atrioventricular node ablation despite minimal difference between pre- and post-ablation heart rates.

    PubMed

    Squara, F; Theodore, G; Scarlatti, D; Ferrari, E

    2017-02-01

    We report the case of an 82-year-old man presenting with ventricular fibrillation (VF) occurring acutely after atrioventricular node (AVN) ablation. This patient had severe valvular cardiomyopathy, chronic atrial fibrillation (AF), and underwent prior to the AVN ablation a biventricular implantable cardiac defibrillator positioning. The VF was successfully cardioverted with one external electrical shock. What makes this presentation original is that the pre-ablation spontaneous heart rate in AF was slow (84 bpm), and that VF occurred after ablation despite a minimal heart rate drop of only 14 bpm. VF is the most feared complication of AVN ablation, but it had previously only been described in case of acute heart rate drop after ablation of at least 30 bpm (and more frequently>50 bpm). This case report highlights the fact that VF may occur after AVN ablation regardless of the heart rate drop, rendering temporary fast ventricular pacing mandatory whatever the pre-ablation heart rate. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  16. Intraosseous Hydroxocobalamin versus Intravenous Hydroxocobalamin Compared to Intraosseous Whole Blood or No Treatment for Hemorrhagic Shock in a Swine Model

    DTIC Science & Technology

    2016-05-02

    MAP significantly improved over time in both treated groups but not in the control group. By 60 minutes, mean HR was 116 and 135 bpm and MAP was 60...and 65 mm Hg for IV and IO HOC groups (not significantly different) whereas non-treated animals displayed a mean HR of 157 bpm and MAP of 43 mm Hg...group. By 60 minutes, mean HR was 116(9.9) and 100(11.2) bpm and MAP was 57(3.9) and 62(4.4) mm Hg for IV HOC and WB groups (not significantly

  17. Modifying middle school physical education: piloting strategies to increase physical activity.

    PubMed

    Jago, Russell; McMurray, Robert G; Bassin, Stanley; Pyle, Laura; Bruecker, Steve; Jakicic, John M; Moe, Esther; Murray, Tinker; Volpe, Stella L

    2009-05-01

    Two pilot studies were conducted to examine whether 6th grade students can achieve moderate to vigorous physical activity (MVPA) from 1) activity-based physical education (AB-PE) with 585 participants and 2) a curricular-based (CB-PE) program with 1,544 participants and randomly sampled heart rates during lessons. AB-PE participants spent between 54-66% with a heart rate >140 bpm. CB-PE participants spent between 49-58% with a heart rate >140 bpm. Girls' mean heart rate was 3.7 bpm lower than the boys. PE can be readily modified so that students spend more than 50% of time in MVPA.

  18. Modifying Middle School Physical Education: Piloting Strategies to Increase Physical Activity

    PubMed Central

    Jago, Russell; McMurray, Robert G.; Bassin, Stanley; Pyle, Laura; Bruecker, Steve; Jakicic, John M.; Moe, Esther; Murray, Tinker; Volpe, Stella L.

    2009-01-01

    Two pilot studies were conducted to examine whether 6th grade students can achieve moderate to vigorous physical activity (MVPA) from 1) activity-based physical education (AB-PE) with 585 participants and 2) a curricular-based (CB-PE) program with 1,544 participants and randomly sampled heart rates during lessons. AB-PE participants spent between 54-66% with a heart rate >140 bpm. CB-PE participants spent between 49-58% with a heart rate >140 bpm. Girls' mean heart rate was 3.7 bpm lower than the boys. PE can be readily modified so that students spend more than 50% of time in MVPA. PMID:19556623

  19. Single-pass BPM system of the Photon Factory storage ring.

    PubMed

    Honda, T; Katoh, M; Mitsuhashi, T; Ueda, A; Tadano, M; Kobayashi, Y

    1998-05-01

    At the 2.5 GeV ring of the Photon Factory, a single-pass beam-position monitor (BPM) system is being prepared for the storage ring and the beam transport line. In the storage ring, the injected beam position during the first several turns can be measured with a single injection pulse. The BPM system has an adequate performance, useful for the commissioning of the new low-emittance lattice. Several stripline BPMs are being installed in the beam transport line. The continuous monitoring of the orbit in the beam transport line will be useful for the stabilization of the injection energy as well as the injection beam orbit.

  20. Wave-Optics Modeling of the Optical-Transport Line for Passive Optical Stochastic Cooling

    DOE PAGES

    Andorf, M. B.; Lebedev, V. A.; Piot, P.; ...

    2018-03-01

    Optical stochastic cooling (OSC) is expected to enable fast cooling of dense particle beams. Transition from microwave to optical frequencies enables an achievement of stochastic cooling rates which are orders of magnitude higher than ones achievable with the classical microwave based stochastic cooling systems. A subsystemcritical to the OSC scheme is the focusing optics used to image radiation from the upstream “pickup” undulator to the downstream “kicker” undulator. In this paper, we present simulation results using wave-optics calculation carried out with the Synchrotron Radiation Workshop (SRW). Our simulations are performed in support to a proof-of-principle experiment planned at the Integrablemore » Optics Test Accelerator (IOTA) at Fermilab. The calculations provide an estimate of the energy kick received by a 100-MeV electron as it propagates in the kicker undulator and interacts with the electromagnetic pulse it radiated at an earlier time while traveling through the pickup undulator.« less

  1. Collimation study for LCLS

    NASA Astrophysics Data System (ADS)

    Marin, E.; Raubenhaimer, T.; Welch, J.; White, G.

    2017-09-01

    In this paper we investigate the power deposition along the undulator section of the SLAC Linac Coherent Light Source (LCLS) due to the primary e--beam but also due to potential secondary particles. The expected beam distribution after the LCLS injector is deliberately broadened as an approximated representation of the beam halo. Secondary particles, as e+, e- and photons, are generated as a result of tracking the intercepted beam through a dense material. This process is carried out by means of GEANT-4, which has been convoluted into our main tracking engine, LUCRETIA. Simulations show no losses along the undulator section when assuming the nominal primary beam and collimator gaps. However when opening the gaps of collimators located at the first collimator section, by 25%, the fattened beam is partially intercepted by the second collimator section, which is aligned to the undulators. Secondary particles, mostly photons generated at the second collimator section, deposit their energy along the undulator section, at a rate of the order of a milliwatt.

  2. Surface-micromachined magnetic undulator with period length between 10μm and 1 mm for advanced light sources

    NASA Astrophysics Data System (ADS)

    Harrison, Jere; Joshi, Abhijeet; Lake, Jonathan; Candler, Rob; Musumeci, Pietro

    2012-07-01

    A technological gap exists between the μm-scale wiggling periods achieved using electromagnetic waves of high intensity laser pulses and the mm scale of permanent-magnet and superconducting undulators. In the sub-mm range, surface-micromachined soft-magnetic micro-electro-mechanical system inductors with integrated solenoidal coils have already experimentally demonstrated 100 to 500 mT field amplitude across air gaps as large as 15μm. Simulations indicate that magnetic fields as large as 1.5 T across 50μm inductor gaps are feasible. A simple rearranging of the yoke and pole geometry allows for fabrication of 10+ cm long undulator structures with period lengths between 12.5μm and 1 mm. Such undulators find application both in high average power spontaneous emission sources and, if used in combination with ultrahigh-brightness electron beams, could lead to the realization of low energy compact free-electron lasers. Challenges include electron energy broadening due to wakefields and Joule heating in the electromagnet.

  3. Magnetic assessment and modelling of the Aramis undulator beamline

    PubMed Central

    Calvi, M.; Camenzuli, C.; Ganter, R.; Sammut, N.; Schmidt, Th.

    2018-01-01

    Within the SwissFEL project at the Paul Scherrer Institute (PSI), the hard X-ray line (Aramis) has been equipped with short-period in-vacuum undulators, known as the U15 series. The undulator design has been developed within the institute itself, while the prototyping and the series production have been implemented through a close collaboration with a Swiss industrial partner, Max Daetwyler AG, and several subcontractors. The magnetic measurement system has been built at PSI, together with all the data analysis tools. The Hall probe has been designed for PSI by the Swiss company SENIS. In this paper the general concepts of both the mechanical and the magnetic properties of the U15 series of undulators are presented. A description of the magnetic measurement equipment is given and the results of the magnetic measurement campaign are reported. Lastly, the data reduction methods and the associated models are presented and their actual implementation in the control system is detailed. PMID:29714179

  4. Characterization and long term operation of a novel superconducting undulator with 15 mm period length in a synchrotron light source

    NASA Astrophysics Data System (ADS)

    Casalbuoni, S.; Cecilia, A.; Gerstl, S.; Glamann, N.; Grau, A. W.; Holubek, T.; Meuter, C.; de Jauregui, D. Saez; Voutta, R.; Boffo, C.; Gerhard, Th.; Turenne, M.; Walter, W.

    2016-11-01

    A new cryogen-free full scale (1.5 m long) superconducting undulator with a period length of 15 mm (SCU15) has been successfully tested in the ANKA storage ring. This represents a very important milestone in the development of superconducting undulators for third and fourth generation light sources carried on by the collaboration between the Karlsruhe Institute of Technology and the industrial partner Babcock Noell GmbH. SCU15 is the first full length device worldwide that with beam reaches a higher peak field than what expected with the same geometry (vacuum gap and period length) with an ideal cryogenic permanent magnet undulator built with the best material available PrFeB. After a summary on the design and main parameters of the device, we present here the characterization in terms of spectral properties and the long term operation of the SCU15 in the ANKA storage ring.

  5. Antiaging activity of low molecular weight peptide from Paphia undulate

    NASA Astrophysics Data System (ADS)

    Chen, Xin; Cai, Bingna; Chen, Hua; Pan, Jianyu; Chen, Deke; Sun, Huili

    2013-05-01

    Low molecular weight peptide (LMWP) was prepared from clam Paphia undulate and its antiaging effect on D-galactose-induced acute aging in rats, aged Kunming mice, ultraviolet-exposed rats, and thermally injured rats was investigated. P. undulate flesh was homogenized and digested using papain under optimal conditions, then subjected to Sephadex G-25 chromatography to isolate the LMWP. Administration of LMWP significantly reversed D-galactose-induced oxidative stress by increasing the activities of glutathione peroxidase (GPx) and catalase (CAT), and by decreasing the level of malondialdehyde (MDA). This process was accompanied by increased collagen synthesis. The LMWP prevented photoaging and promoted dermis recovery and remission of elastic fiber hyperplasia. Furthermore, treatment with the LMWP helped to regenerate elastic fibers and the collagen network, increased superoxide dismutase (SOD) in the serum and significantly decreased MDA. Thermal scald-induced inflammation and edema were also relieved by the LWMP, while wound healing in skin was promoted. These results suggest that the LMWP from P. undulate could serve as a new antiaging substance in cosmetics.

  6. Negative-mass mitigation of Coulomb repulsion for terahertz undulator radiation of electron bunches

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Balal, N.; Magory, E.; Bandurkin, I. V.

    2015-10-19

    It is proposed to utilize the effect of negative mass for stabilization of the effective axial size of very dense and short electron bunches produced by photo-injector guns by using combined undulator and strong uniform magnetic fields. It has been shown that in the “abnormal” regime, an increase in the electron energy leads to a decrease in the axial velocity of the electron; due to the negative-mass effect, the Coulomb repulsion of electrons leads to their attraction and formation of a fairly stable and compact bunch “nucleus.” An undulator with a strong uniform magnetic field providing the negative-mass effect ismore » designed for an experimental source of terahertz radiation. The use of the negative-mass regime in this experiment should result in a long-pulse coherent spontaneous undulator emission from a short dense moderately relativistic (5.5 MeV) photo-injector electron bunch with a high (up to 20%) efficiency and a narrow frequency spectrum.« less

  7. Theory of electromagnetic insertion devices and the corresponding synchrotron radiation

    NASA Astrophysics Data System (ADS)

    Shumail, Muhammad; Tantawi, Sami G.

    2016-07-01

    Permanent magnet insertion devices (IDs), which are the main radiation generating devices in synchrotron light sources and free-electron lasers, use a time-invariant but space-periodic magnetic field to wiggle relativistic electrons for short-wavelength radiation generation. Recently, a high power microwave based undulator has also been successfully demonstrated at SLAC which promises the advantage of dynamic tunability of radiation spectrum and polarization. Such IDs employ transverse elecromagnetic fields which are periodic in both space and time to undulate the electrons. In this paper we develop a detailed theory of the principle of electromagnetic IDs from first principles for both linear and circular polarization modes. The electromagnetic equivalent definitions of undulator period (λu) and undulator deflection parameter (K ) are derived. In the inertial frame where the average momentum of the electron is zero, we obtain the figure-8-like trajectory for the linear polarization mode and the circular trajectory for the circular polarization mode. The corresponding radiation spectra and the intensity of harmonics is also calculated.

  8. Applications Where Snap is BPM for Radioactive Waste Assay

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, T.J.

    2008-07-01

    Historically, the Atomic Weapons Establishment (AWE) at Aldermaston in the United Kingdom (UK), has used a variety of assay techniques to measure the radioactive content of a diverse range of waste packages from decommissioning, operational and legacy sources. The regulator, the Environment Agency in the UK, places conditions and limits on AWE through an authorisation within the Radioactive Substances Act (RSA93). The conditions and limits require Best Practical Means (BPM) measurements to be used to demonstrate compliance with the authorisation. Hence, the assay technique employed needs to achieve a balance between risk of exposure, environmental considerations, technological considerations, health andmore » safety considerations and cost effectiveness, without being grossly disproportionate in terms of money, time or trouble. Recently published work has concluded that the Spectral Non-destructive Assay Platform (SNAP) assay system is BPM for Depleted Uranium (DU) waste assay at AWE (1) and low level plutonium in soft drummed waste, HEPA filters and soils (2-4). The purpose of this paper is to highlight other applications where SNAP represents BPM for radioactive waste assay. This has been done by intercomparison studies of SNAP with other assay techniques, such as Segmented Gamma Scanner (SGS) and Passive Neutron Coincidence Counter (PNCC). It has been concluded that, for a large range of waste packages encountered at AWE, SNAP is BPM. (author)« less

  9. Development and operating experience of a short-period superconducting undulator at the Advanced Photon Source

    DOE PAGES

    Ivanyushenkov, Y.; Harkay, K.; Abliz, M.; ...

    2015-04-01

    In this study, a decade-long effort at the Advanced Photon Source (APS) of Argonne National Laboratory (ANL) on development of superconducting undulators culminated in December 2012 with the installation of the first superconducting undulator “SCU0” into Sector 6 of the APS storage ring. The device was commissioned in January 2013 and has been in user operation since. This paper presents the magnetic and cryogenic design of the SCU0 together with the results of stand-alone cold tests. The initial commissioning and characterization of SCU0 as well as its operating experience in the APS storage ring are described.

  10. Ice Velocity Mapping of Ross Ice Shelf, Antarctica by Matching Surface Undulations Measured by Icesat Laser Altimetry

    NASA Technical Reports Server (NTRS)

    Lee, Choon-Ki; Han, Shin-Chan; Yu, Jaehyung; Scambos, Ted A.; Seo, Ki-Weon

    2012-01-01

    We present a novel method for estimating the surface horizontal velocity on ice shelves using laser altimetrydata from the Ice Cloud and land Elevation Satellite (ICESat; 20032009). The method matches undulations measured at crossover points between successive campaigns.

  11. Electron Beam Diagnostics Of The JLAB UV FEL

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Evtushenko, Pavel; Benson, Stephen; Biallas, George

    2011-03-01

    In this contribution we describe various systems and aspects of the electron beam diagnostics of the JLab UV FEL. The FEL is installed on a new bypass beam line at the existing 10 kW IR Upgrade FEL. Here, we describe a set of the following systems. A combination of OTR and phosphor viewers is used for measurements of the transverse beam profile, transverse emittance, and Twiss parameters. This system is also used for alignment of the optical cavity of the UV oscillator and to ensure the overlap between the electron beam and optical mode in the FEL wiggler. A systemmore » of beam position monitors equipped with log-amp based BPM electronics. Bunch length on the order of 120 fs RMS is measured with the help of a modified Martin-Puplett interferometer. The longitudinal transfer function measurement system is used to set up bunch compression in an optimal way, such that the LINAC RF curvature is compensated using only higher order magnetic elements of the beam transport. This set of diagnostic systems made a significant contribution in achieving first lasing of the FEL after only about 60 hours of beam operation.« less

  12. Assembly and analysis of a male sterile rubber tree mitochondrial genome reveals DNA rearrangement events and a novel transcript

    PubMed Central

    2014-01-01

    Background The rubber tree, Hevea brasiliensis, is an important plant species that is commercially grown to produce latex rubber in many countries. The rubber tree variety BPM 24 exhibits cytoplasmic male sterility, inherited from the variety GT 1. Results We constructed the rubber tree mitochondrial genome of a cytoplasmic male sterile variety, BPM 24, using 454 sequencing, including 8 kb paired-end libraries, plus Illumina paired-end sequencing. We annotated this mitochondrial genome with the aid of Illumina RNA-seq data and performed comparative analysis. We then compared the sequence of BPM 24 to the contigs of the published rubber tree, variety RRIM 600, and identified a rearrangement that is unique to BPM 24 resulting in a novel transcript containing a portion of atp9. Conclusions The novel transcript is consistent with changes that cause cytoplasmic male sterility through a slight reduction to ATP production efficiency. The exhaustive nature of the search rules out alternative causes and supports previous findings of novel transcripts causing cytoplasmic male sterility. PMID:24512148

  13. Submicron multi-bunch BPM for CLIC

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schmickler, H.; Soby, L.; /CERN

    2010-08-01

    A common-mode free cavity BPM is currently under development at Fermilab within the ILC-CLIC collaboration. This monitor will be operated in a CLIC Main Linac multi-bunch regime, and needs to provide both, high spatial and time resolution. We present the design concept, numerical analysis, investigation on tolerances and error effects, as well as simulations on the signal response applying a multi-bunch stimulus. The proposed CERN linear collider (CLIC) requires a very precise measurement of beam trajectory to preserve the low emittance when transporting the beam through the Main Linac. An energy chirp within the bunch train will be applied tomore » measure and minimize the dispersion effects, which require high resolution (in both, time and space) beam position monitors (BPM) along the beam-line. We propose a low-Q waveguide loaded TM{sub 110} dipole mode cavity as BPM, which is complemented by a TM{sub 010} monopole mode resonator of same resonant frequency for reference signal purposes. The design is based on a well known TM{sub 110} selective mode coupling idea.« less

  14. Growth performance and carcase quality in broiler chickens fed on bacterial protein grown on natural gas.

    PubMed

    Øverland, M; Schøyen, H F; Skrede, A

    2010-10-01

    1. The effects of increasing concentrations (0, 40, 80 or 120 g/kg) of bacterial protein meal (BPM) and bacterial protein autolysate (BPA) grown on natural gas on growth performance and carcase quality in broiler chickens were examined. 2. Adding BPM to diets reduced feed intake and improved gain: feed from 0 to 21 d and overall to 35 d, but did not significantly affect weight gain compared to the soybean meal based control diet. 3. Increasing concentrations of BPA significantly reduced growth rate, feed intake, gain: feed, carcase weight and dressing percentage, but significantly increased carcase dry matter, fat and energy content. 4. Adding BPM to diets had no effect on viscosity of diets and jejunal digesta, and minor effects on litter quality, whereas BPA increased the viscosity of diets and jejunal digesta, improved litter quality at 21 d, but decreased litter quality at 32 d. 5. To conclude, broiler chickens performed better on a BPM product with intact proteins than on an autolysate with ruptured cell walls and a high content of free amino acids and low molecular-weight peptides.

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schmidt, T.; Imhof, A.; Ingold, G.

    To vary the polarization vector of an APPLE II undulator continuously from 0 - 180 deg., all four magnet arrays need to be movable. Following the adjustable-phase undulator approach by R. Carr, a 3.4 m long fixed gap undulator for SLS with a gap of 11.6 mm has been constructed. It will be installed in fall 2006. The gap drive is replaced by a pair-wise shift of the magnet arrays to change the energy, while the polarization is changed by shifts of diagonal arrays. The high injection efficiency and standard operation top-up mode at the SLS allows this simplified undulatormore » design. The design as well as the operational aspects will be discussed.« less

  16. Surface-potential undulation of Alq3 thin films prepared on ITO, Au, and n-Si.

    PubMed

    Ozasa, Kazunari; Ito, Hiromi; Maeda, Mizuo; Hara, Masahiko

    2012-01-01

    The surface potential (SP) morphology on thin films of tris(8-hydroxyquinolinato) aluminum (Alq3) was investigated with Kelvin probe force microscopy. Thin Alq3 films of 100 nm were prepared on ITO/glass substrates, Au/mica substrates, and n-Si substrates. Cloud-like morphologies of the SP undulation with 200-400 nm in lateral size were observed for all three types of the substrates. New larger peaks were observed in the cloud-like morphologies when the surfaces were exposed shortly to a light, while the SP average was reduced monotonically. The nonuniform distribution of charged traps and mobility was deduced from the SP undulation morphology and its photoexposure dependences.

  17. Method for the production of wideband THz radiation

    DOEpatents

    Krafft, Geoffrey A [Newport News, VA

    2008-01-01

    A method for the production of extremely wide bandwidth THz radiation comprising: delivering an electron beam from a source to an undulator that does not deflect the angle or transversely move the electron beam; and optimizing the undulator to yield peak emission in the middle of the THz band (1 THz). These objectives are accomplished by magnetically bending the orbit of the incoming electron beam in the undulator according to the function x(z)=x.sub.o exp(-z.sup.2/2.sigma..sup.2) and controlling the transverse magnetic field to be B(z)=B.sub.0(1-z.sup.2/.sigma..sup.2)exp(-z.sup.2/2.sigma..sup.2).

  18. Electromechanical Wave Imaging of biologically and electrically paced canine hearts in vivo

    PubMed Central

    Costet, Alexandre; Provost, Jean; Gambhir, Alok; Bobkov, Yevgeniy; Danilo, Peter; Boink, Gerard J.J.; Rosen, Michael R.; Konofagou, Elisa

    2014-01-01

    Ultrasound-based, Electromechanical Wave (EW) Imaging (EWI) can directly and entirely noninvasively map the transmural electromechanical activation in all four cardiac chambers in vivo. In this study, we assessed EWI repeatability and reproducibility, as well as its capability in localizing electronic and, for the first time, biological pacemakers in closed-chest, conscious canines. Electromechanical activation was obtained in six conscious animals during normal sinus rhythm (NSR), and idioventricular rhythms occurring in dogs in heart block instrumented with electronic and biological pacemakers (EPM and BPM respectively). After AV node ablation, dogs were implanted with an EPM in the right ventricular (RV) endocardial apex (n=4) and two additionally received a BPM at the left ventricular (LV) epicardial base (n=2). EWI was performed transthoracically during NSR, BPM, and EPM pacing, in conscious dogs, using an unfocused transmit sequence at 2000 frames/second. During NSR, the EW originated at the right atrium (RA), propagated to the left atrium (LA) and emerged from multiple sources in both ventricles. During EPM, the EW originated at the RV apex and propagated throughout both ventricles. During BPM, the EW originated from the LV basal lateral wall and subsequently propagated throughout the ventricles. EWI differentiated BPM from EPM and NSR and identified the distinct pacing origins. Isochrone comparison demonstrated that EWI was repeatable and reliable. These findings thus indicate the EWI potential to serve as a simple, noninvasive and direct imaging technology for mapping and characterizing arrhythmias as well as the treatments thereof. PMID:24239363

  19. Autonomic Dysfunction Precedes Development of Rheumatoid Arthritis: A Prospective Cohort Study

    PubMed Central

    Koopman, F.A.; Tang, M.W.; Vermeij, J.; de Hair, M.J.; Choi, I.Y.; Vervoordeldonk, M.J.; Gerlag, D.M.; Karemaker, J.M.; Tak, P.P.

    2016-01-01

    Background Heart rate variability (HRV) is a validated method to establish autonomic nervous system (ANS) activity. Rheumatoid arthritis (RA) is accompanied by ANS imbalance. We hypothesized that ANS dysfunction may precede the development of RA, which would suggest that it plays a role in its etiopathogenesis. Methods First, we assessed HRV parameters in supine (resting) and upright (active) position in healthy subjects (HS, n = 20), individuals at risk of developing arthritis (AR subjects, n = 50) and RA patients (RA, n = 20). Next, we measured resting heart rate (RHR), a parasympathetic HRV parameter, in an independent prospective cohort of AR subjects (n = 45). We also evaluated expression levels of the parasympathetic nicotinic acetylcholine receptor type 7 (α7nAChR) on circulating monocytes. Findings Both AR subjects (68 beats per minute (bpm), interquartile range (IQR) 68–73) and RA patients (68 bpm, IQR 62–76) had a significantly higher RHR compared to HS (60 bpm, IQR 56–63). RHR was significantly higher at baseline in individuals who subsequently developed arthritis. Expression levels of α7nAChR were lower in AR subjects with RHR ≥ 70 bpm compared to those with RHR < 70 bpm, consistent with reduced activity of the parasympathetic cholinergic anti-inflammatory pathway. Interpretation These data support the notion that autonomic dysfunction precedes the development of RA. PMID:27211565

  20. CoNNeCT Baseband Processor Module Boot Code SoftWare (BCSW)

    NASA Technical Reports Server (NTRS)

    Yamamoto, Clifford K.; Orozco, David S.; Byrne, D. J.; Allen, Steven J.; Sahasrabudhe, Adit; Lang, Minh

    2012-01-01

    This software provides essential startup and initialization routines for the CoNNeCT baseband processor module (BPM) hardware upon power-up. A command and data handling (C&DH) interface is provided via 1553 and diagnostic serial interfaces to invoke operational, reconfiguration, and test commands within the code. The BCSW has features unique to the hardware it is responsible for managing. In this case, the CoNNeCT BPM is configured with an updated CPU (Atmel AT697 SPARC processor) and a unique set of memory and I/O peripherals that require customized software to operate. These features include configuration of new AT697 registers, interfacing to a new HouseKeeper with a flash controller interface, a new dual Xilinx configuration/scrub interface, and an updated 1553 remote terminal (RT) core. The BCSW is intended to provide a "safe" mode for the BPM when initially powered on or when an unexpected trap occurs, causing the processor to reset. The BCSW allows the 1553 bus controller in the spacecraft or payload controller to operate the BPM over 1553 to upload code; upload Xilinx bit files; perform rudimentary tests; read, write, and copy the non-volatile flash memory; and configure the Xilinx interface. Commands also exist over 1553 to cause the CPU to jump or call a specified address to begin execution of user-supplied code. This may be in the form of a real-time operating system, test routine, or specific application code to run on the BPM.

  1. Hatching behavior of eastern long-necked turtles (Chelodina longicollis): The influence of asynchronous environments on embryonic heart rate and phenotype.

    PubMed

    McGlashan, Jessica K; Loudon, Fiona K; Thompson, Michael B; Spencer, Ricky-John

    2015-10-01

    Variable temperatures within a nest cause asynchronous development within clutches of freshwater turtle embryos, yet synchronous hatching occurs and is thought to be an important survival strategy for hatchlings. Metabolic compensation and circadian rhythms in heart rates of embryonic turtles indicate the potential of communication between embryos in a nest. Heart rates were used to identify metabolic circadian rhythms in clutches of an Australian freshwater turtle (Chelodina longicollis) and determine whether embryos metabolically compensate and hatch synchronously when incubated in asynchronous environments. The effects of a group environment during incubation on egg development and incubation period were also investigated during the final 3 weeks of development. Chelodina longicollis hatch synchronously and metabolically compensate so that less advanced embryos catch up to more advanced clutch-mates. Heart rates of embryos remained stable from week 4-7 in asynchronous (M=89 bpm) and synchronous (M=92 bpm) groups and declined in the final 2 weeks of incubation (M=72 and 77 bpm). Circadian rhythms were present throughout development and diel heart rates of embryos in asynchronous groups showed less deviation from the mean (M=-0.5 bpm) than synchronous groups (M=-4 bpm). Eggs incubated in groups had a significantly shorter incubation period than eggs incubated individually. Phenotypic traits including size, performance, and growth of all hatchlings were not affected. Egg position within a turtle nest is important for coordinating development throughout incubation and facilitating synchronous hatching. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. Validation of the AVITA BPM64 upper-arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    PubMed

    Kang, Yuan-Yuan; Chen, Qi; Liu, Chang-Yuan; Li, Yan; Wang, Ji-Guang

    2018-02-01

    The aim of this study was to evaluate the accuracy of the automated oscillometric upper arm blood pressure (BP) monitor AVITA BPM64 for home BP monitoring according to the International Protocol of the European Society of Hypertension revision 2010. Systolic and diastolic BPs were measured sequentially in 33 adult Chinese (14 women, mean age 47.0 years) using a mercury sphygmomanometer (two observers) and the AVITA BPM64 device (one supervisor). A total of 99 pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. The AVITA BPM64 device achieved the targets in part 1 of the validation study. The number of absolute differences between device and observers within 5, 10, and 15 mmHg was 91/99, 98/99, and 98/99, respectively, for systolic BP and 92/99, 99/99, and 99/99, respectively, for diastolic BP. The device also fulfilled the criteria in part 2 of the validation study. Thirty-two participants for both systolic and diastolic BP had at least two of the three device-observer differences within 5 mmHg (required ≥24). Only one participant for systolic BP had all three device-observer comparisons greater than 5 mmHg. The AVITA upper arm BP monitor BPM64 has passed the requirements of the International Protocol revision 2010, and hence can be recommended for home use in adults.

  3. BPM-CUL3 E3 ligase modulates thermotolerance by facilitating negative regulatory domain-mediated degradation of DREB2A in Arabidopsis

    PubMed Central

    Morimoto, Kyoko; Ohama, Naohiko; Kidokoro, Satoshi; Mizoi, Junya; Takahashi, Fuminori; Todaka, Daisuke; Mogami, Junro; Sato, Hikaru; Qin, Feng; Kim, June-Sik; Fukao, Yoichiro; Fujiwara, Masayuki; Shinozaki, Kazuo; Yamaguchi-Shinozaki, Kazuko

    2017-01-01

    DEHYDRATION-RESPONSIVE ELEMENT BINDING PROTEIN 2A (DREB2A) acts as a key transcription factor in both drought and heat stress tolerance in Arabidopsis and induces the expression of many drought- and heat stress-inducible genes. Although DREB2A expression itself is induced by stress, the posttranslational regulation of DREB2A, including protein stabilization, is required for its transcriptional activity. The deletion of a 30-aa central region of DREB2A known as the negative regulatory domain (NRD) transforms DREB2A into a stable and constitutively active form referred to as DREB2A CA. However, the molecular basis of this stabilization and activation has remained unknown for a decade. Here we identified BTB/POZ AND MATH DOMAIN proteins (BPMs), substrate adaptors of the Cullin3 (CUL3)-based E3 ligase, as DREB2A-interacting proteins. We observed that DREB2A and BPMs interact in the nuclei, and that the NRD of DREB2A is sufficient for its interaction with BPMs. BPM-knockdown plants exhibited increased DREB2A accumulation and induction of DREB2A target genes under heat and drought stress conditions. Genetic analysis indicated that the depletion of BPM expression conferred enhanced thermotolerance via DREB2A stabilization. Thus, the BPM-CUL3 E3 ligase is likely the long-sought factor responsible for NRD-dependent DREB2A degradation. Through the negative regulation of DREB2A stability, BPMs modulate the heat stress response and prevent an adverse effect of excess DREB2A on plant growth. Furthermore, we found the BPM recognition motif in various transcription factors, implying a general contribution of BPM-mediated proteolysis to divergent cellular responses via an accelerated turnover of transcription factors. PMID:28923951

  4. Comparison of the Microlife blood pressure monitor with the Omron blood pressure monitor for detecting atrial fibrillation.

    PubMed

    Wiesel, Joseph; Arbesfeld, Benjamin; Schechter, David

    2014-10-01

    Screening for atrial fibrillation (AF) by assessing the pulse is recommended in high-risk patients. Some clinical trials demonstrated that the Microlife blood pressure monitor (BPM) with AF detection is more accurate than pulse palpation. This led to a change in practice guidelines in the United Kingdom where AF screening with the Microlife device is recommended instead of pulse palpation. Many BPMs have irregular heart beat detection, but they have not been shown to detect AF reliably. Recently, one study, in a highly select population, suggested that the Omron BPM with irregular heart beat detection has a higher sensitivity for AF than the Microlife BPM. We compared the Microlife and Omron BPMs to electrocardiographic readings for AF detection in general cardiology patients. Inclusion criteria were age≥50 years without a pacemaker or defibrillator. A total of 199 subjects were enrolled, 30 with AF. Each subject had a 12-lead electrocardiography, 1 Omron BPM reading, and 3 Microlife BPM readings as per device instructions. The Omron device had a sensitivity of 30% (95% confidence interval [CI] 15.4% to 49.1%) with the sensitivity for the first Microlife reading of 97% (95% CI 81.4% to 100%) and the Microlife readings using the majority rule (AF positive if at least 2 of 3 individual readings were positive for AF) of 100% (95% CI 85.9% to 100%). Specificity for the Omron device was 97% (95% CI 92.5% to 99.2%) and for the first Microlife reading of 90% (95% CI 83.8% to 94.2%) and for the majority rule Microlife device of 92% (95% CI 86.2% to 95.7%; p<0.0001). The specificity of both devices is acceptable, but only the Microlife BPM has a sensitivity value that is high enough to be used for AF screening in clinical practice. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. An assessment of algorithms to estimate respiratory rate from the electrocardiogram and photoplethysmogram.

    PubMed

    Charlton, Peter H; Bonnici, Timothy; Tarassenko, Lionel; Clifton, David A; Beale, Richard; Watkinson, Peter J

    2016-04-01

    Over 100 algorithms have been proposed to estimate respiratory rate (RR) from the electrocardiogram (ECG) and photoplethysmogram (PPG). As they have never been compared systematically it is unclear which algorithm performs the best. Our primary aim was to determine how closely algorithms agreed with a gold standard RR measure when operating under ideal conditions. Secondary aims were: (i) to compare algorithm performance with IP, the clinical standard for continuous respiratory rate measurement in spontaneously breathing patients; (ii) to compare algorithm performance when using ECG and PPG; and (iii) to provide a toolbox of algorithms and data to allow future researchers to conduct reproducible comparisons of algorithms. Algorithms were divided into three stages: extraction of respiratory signals, estimation of RR, and fusion of estimates. Several interchangeable techniques were implemented for each stage. Algorithms were assembled using all possible combinations of techniques, many of which were novel. After verification on simulated data, algorithms were tested on data from healthy participants. RRs derived from ECG, PPG and IP were compared to reference RRs obtained using a nasal-oral pressure sensor using the limits of agreement (LOA) technique. 314 algorithms were assessed. Of these, 270 could operate on either ECG or PPG, and 44 on only ECG. The best algorithm had 95% LOAs of  -4.7 to 4.7 bpm and a bias of 0.0 bpm when using the ECG, and  -5.1 to 7.2 bpm and 1.0 bpm when using PPG. IP had 95% LOAs of  -5.6 to 5.2 bpm and a bias of  -0.2 bpm. Four algorithms operating on ECG performed better than IP. All high-performing algorithms consisted of novel combinations of time domain RR estimation and modulation fusion techniques. Algorithms performed better when using ECG than PPG. The toolbox of algorithms and data used in this study are publicly available.

  6. Accuracy of a Wrist-Worn Wearable Device for Monitoring Heart Rates in Hospital Inpatients: A Prospective Observational Study.

    PubMed

    Kroll, Ryan R; Boyd, J Gordon; Maslove, David M

    2016-09-20

    As the sensing capabilities of wearable devices improve, there is increasing interest in their application in medical settings. Capabilities such as heart rate monitoring may be useful in hospitalized patients as a means of enhancing routine monitoring or as part of an early warning system to detect clinical deterioration. To evaluate the accuracy of heart rate monitoring by a personal fitness tracker (PFT) among hospital inpatients. We conducted a prospective observational study of 50 stable patients in the intensive care unit who each completed 24 hours of heart rate monitoring using a wrist-worn PFT. Accuracy of heart rate recordings was compared with gold standard measurements derived from continuous electrocardiographic (cECG) monitoring. The accuracy of heart rates measured by pulse oximetry (Spo2.R) was also measured as a positive control. On a per-patient basis, PFT-derived heart rate values were slightly lower than those derived from cECG monitoring (average bias of -1.14 beats per minute [bpm], with limits of agreement of 24 bpm). By comparison, Spo2.R recordings produced more accurate values (average bias of +0.15 bpm, limits of agreement of 13 bpm, P<.001 as compared with PFT). Personal fitness tracker device performance was significantly better in patients in sinus rhythm than in those who were not (average bias -0.99 bpm vs -5.02 bpm, P=.02). Personal fitness tracker-derived heart rates were slightly lower than those derived from cECG monitoring in real-world testing and not as accurate as Spo2.R-derived heart rates. Performance was worse among patients who were not in sinus rhythm. Further clinical evaluation is indicated to see if PFTs can augment early warning systems in hospitals. ClinicalTrials.gov NCT02527408; https://clinicaltrials.gov/ct2/show/NCT02527408 (Archived by WebCite at  http://www.webcitation.org/6kOFez3on).

  7. Diurnal, seasonal, and sex patterns of heart rate in grip-restrained African giant rats (Cricetomys gambianus, Waterhouse).

    PubMed

    Dzenda, Tavershima; Ayo, Joseph O; Sinkalu, Victor O; Yaqub, Lukuman S

    2015-10-01

    This study was carried out to determine heart rate (HR) values, including diurnal, seasonal, and sex patterns, in the African giant rat (Cricetomys gambianus, Waterhouse). HR was measured using stethoscope in grip-restrained African giant rats of either sex (103 bucks and 98 does), live-trapped from a tropical Savannah, and caged individually in the laboratory during the harmattan (cold-dry), hot-dry, and rainy seasons over a 3-year period. The HR fluctuated between 90 and 210 beats per minute (bpm) throughout the study period. Diurnal changes in HR (mean ± SEM) during the hot-dry and rainy seasons were nonsignificant (P > 0.05), but the morning and afternoon values differed (P < 0.01) during the cold-dry season. The HR varied (P < 0.05) among seasons, with peak, nadir, and moderate values recorded during the cold-dry (165.8 ± 0.51 bpm), hot-dry (153.1 ± 0.74 bpm), and rainy (163.4 ± 0.70 bpm) seasons, respectively. Mean HR of bucks was lower than that of does during the cold-dry (P < 0.0001) and hot-dry (P < 0.01) seasons, but sex difference during the rainy season was insignificant (P > 0.05). Overall, mean HR was lower (P < 0.0001) in bucks (158.8 ± 0.53 bpm) than in does (164.8 ± 0.53 bpm). In conclusion, values of HR in African giant rats are shown for the first time. Season, sex, and daytime influenced the HR, and should be considered during clinical evaluations of the rats. © 2015 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of the American Physiological Society and The Physiological Society.

  8. An assessment of algorithms to estimate respiratory rate from the electrocardiogram and photoplethysmogram

    PubMed Central

    Charlton, Peter H; Bonnici, Timothy; Tarassenko, Lionel; Clifton, David A; Beale, Richard; Watkinson, Peter J

    2016-01-01

    Abstract Over 100 algorithms have been proposed to estimate respiratory rate (RR) from the electrocardiogram (ECG) and photoplethysmogram (PPG). As they have never been compared systematically it is unclear which algorithm performs the best. Our primary aim was to determine how closely algorithms agreed with a gold standard RR measure when operating under ideal conditions. Secondary aims were: (i) to compare algorithm performance with IP, the clinical standard for continuous respiratory rate measurement in spontaneously breathing patients; (ii) to compare algorithm performance when using ECG and PPG; and (iii) to provide a toolbox of algorithms and data to allow future researchers to conduct reproducible comparisons of algorithms. Algorithms were divided into three stages: extraction of respiratory signals, estimation of RR, and fusion of estimates. Several interchangeable techniques were implemented for each stage. Algorithms were assembled using all possible combinations of techniques, many of which were novel. After verification on simulated data, algorithms were tested on data from healthy participants. RRs derived from ECG, PPG and IP were compared to reference RRs obtained using a nasal-oral pressure sensor using the limits of agreement (LOA) technique. 314 algorithms were assessed. Of these, 270 could operate on either ECG or PPG, and 44 on only ECG. The best algorithm had 95% LOAs of  −4.7 to 4.7 bpm and a bias of 0.0 bpm when using the ECG, and  −5.1 to 7.2 bpm and 1.0 bpm when using PPG. IP had 95% LOAs of  −5.6 to 5.2 bpm and a bias of  −0.2 bpm. Four algorithms operating on ECG performed better than IP. All high-performing algorithms consisted of novel combinations of time domain RR estimation and modulation fusion techniques. Algorithms performed better when using ECG than PPG. The toolbox of algorithms and data used in this study are publicly available. PMID:27027672

  9. Is 10-second electrocardiogram recording enough for accurately estimating heart rate in atrial fibrillation.

    PubMed

    Shuai, Wei; Wang, Xi-Xing; Hong, Kui; Peng, Qiang; Li, Ju-Xiang; Li, Ping; Chen, Jing; Cheng, Xiao-Shu; Su, Hai

    2016-07-15

    At present, the estimation of rest heart rate (HR) in atrial fibrillation (AF) is obtained by apical auscultation for 1min or on the surface electrocardiogram (ECG) by multiplying the number of RR intervals on the 10second recording by six. But the reasonability of 10second ECG recording is controversial. ECG was continuously recorded at rest for 60s to calculate the real rest HR (HR60s). Meanwhile, the first 10s and 30s ECG recordings were used for calculating HR10s (sixfold) and HR30s (twofold). The differences of HR10s or HR30s with the HR60s were compared. The patients were divided into three sub-groups on the HR60s <80, 80-100 and >100bpm. No significant difference among the mean HR10s, HR30s and HR60s was found. A positive correlation existed between HR10s and HR60s or HR30s and HR60s. Bland-Altman plot showed that the 95% reference limits were high as -11.0 to 16.0bpm for HR10s, but for HR30s these values were only -4.5 to 5.2bpm. Among the three subgroups with HR60s <80, 80-100 and >100bpm, the 95% reference limits with HR60s were -8.9 to 10.6, -10.5 to 14.0 and -11.3 to 21.7bpm for HR10s, but these values were -3.9 to 4.3, -4.1 to 4.6 and -5.3 to 6.7bpm for HR30s. As 10s ECG recording could not provide clinically accepted estimation HR, ECG should be recorded at least for 30s in the patients with AF. It is better to record ECG for 60s when the HR is rapid. Copyright © 2016. Published by Elsevier Ireland Ltd.

  10. Impact of heart rate in atrial fibrillation versus sinus rhythm on mortality in octogenarian patients with acute coronary syndrome.

    PubMed

    Li, Shijun; Barywani, Salim; Fu, Michael

    2017-01-01

    Association of heart rate (HR) with mortality in patients with acute coronary syndrome (ACS) and aged ≥ 80 years are underrepresented in clinical trials. We therefore aimed to investigate the association of HR in atrial fibrillation (AF) versus sinus rhythm (SR) with all-cause mortality in octogenarian patients with ACS. A total of 336 patients with ACS patients and aged ≥ 80 years were enrolled into the current study. The end point of interest was death from any cause. Association of HR in AF versus SR with mortality was analyzed by Kaplan-Meier curve following log-rank test and multivariable Cox regression analysis. In total, 63 (87.5%) of patients with AF were dead and 147 (59.8%) of patients with SR were dead during the follow-up period. The best cut-off was 80 bpm, with a sensitivity of 62% and specificity of 66%. HR ≤ 80 bpm in SR but not in AF was associated with better outcome as compared with HR > 80 bpm (Chi-Square = 26.55, Log rank P < 0.001). In SR subgroup, the hazard ratios of HR ≤ 80 bpm were 0.51(95% CI 0.37-0.70, P < 0.001) adjusted for age, 0.46 (95%CI 0.33-0.63, P < 0.001) adjusted for gender, 0.62 (95%CI 0.42- 0.93, P = 0.020) adjusted for multivariables respectively. In AF subgroup, the hazard ratios of HR ≤ 80 bpm were 0.83(95% CI 0.49-1.38, P = 0.464) adjusted for age, 0.96 (95%CI 0.59-1.58, P = 0.882) adjusted for gender, 0.72(95% CI 0.41-1.26, P = 0.249) adjusted for multivariables respectively. The current study demonstrates that heart rate is an independent prognostic predictor for all-cause mortality, and HR ≤ 80 bpm is associated with improved outcome in SR but not in AF in octogenarian patients with ACS.

  11. Micropole undulator

    DOEpatents

    Tatchyn, Roman O.; Csonka, Paul L.; Cremer, Jay T.

    1990-12-11

    Micropole undulators for use in the generation of x-rays from moving charged particles are disclosed. Two rows of spaced apart poles are arranged so that each pole produces a magnetic field aligned with all other similar fields. The poles are the ends of "C"-shaped magnets. In each row, adjacent poles are separated by spacers made of a superconducting material.

  12. Microwave and plasma-assisted modification of composite fiber surface topography

    DOEpatents

    Paulauskas, Felix L [Knoxville, TN; White, Terry L [Knoxville, TN; Bigelow, Timothy S [Knoxville, TN

    2003-02-04

    The present invention introduces a novel method for producing an undulated surface on composite fibers using plasma technology and microwave radiation. The undulated surface improves the mechanical interlocking of the fibers to composite resins and enhances the mechanical strength and interfacial sheer strength of the composites in which they are introduced.

  13. Evolution of Martian polar landscapes - Interplay of long-term variations in perennial ice cover and dust storm intensity

    NASA Technical Reports Server (NTRS)

    Cutts, J. A.; Blasius, K. R.; Roberts, W. J.

    1979-01-01

    The discovery of a new type of Martian polar terrain, called undulating plain, is reported and the evolution of the plains and other areas of the Martian polar region is discussed in terms of the trapping of dust by the perennial ice cover. High-resolution Viking Orbiter 2 observations of the north polar terrain reveal perennially ice-covered surfaces with low relief, wavelike, regularly spaced, parallel ridges and troughs (undulating plains) occupying areas of the polar terrain previously thought to be flat, and associated with troughs of considerable local relief which exhibit at least partial annual melting. It is proposed that the wavelike topography of the undulating plains originates from long-term periodic variations in cyclical dust precipitation at the margin of a growing or receding perennial polar cap in response to changes in insolation. The troughs are proposed to originate from areas of steep slope in the undulating terrain which have lost their perennial ice cover and have become incapable of trapping dust. The polar landscape thus appears to record the migrations, expansions and contractions of the Martian polar cap.

  14. Theory of electromagnetic insertion devices and the corresponding synchrotron radiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shumail, Muhammad; Tantawi, Sami G.

    Permanent magnet insertion devices (IDs), which are the main radiation generating devices in synchrotron light sources and free-electron lasers, use a time-invariant but space-periodic magnetic field to wiggle relativistic electrons for short-wavelength radiation generation. Recently, a high power microwave based undulator has also been successfully demonstrated at SLAC which promises the advantage of dynamic tunability of radiation spectrum and polarization. Such IDs employ transverse elecromagnetic fields which are periodic in both space and time to undulate the electrons. In this paper we develop a detailed theory of the principle of electromagnetic IDs from first principles for both linear and circularmore » polarization modes. The electromagnetic equivalent definitions of undulator period (λ u) and undulator deflection parameter (K) are derived. In the inertial frame where the average momentum of the electron is zero, we obtain the figure-8-like trajectory for the linear polarization mode and the circular trajectory for the circular polarization mode. As a result, the corresponding radiation spectra and the intensity of harmonics is also calculated.« less

  15. Theory of electromagnetic insertion devices and the corresponding synchrotron radiation

    DOE PAGES

    Shumail, Muhammad; Tantawi, Sami G.

    2016-07-27

    Permanent magnet insertion devices (IDs), which are the main radiation generating devices in synchrotron light sources and free-electron lasers, use a time-invariant but space-periodic magnetic field to wiggle relativistic electrons for short-wavelength radiation generation. Recently, a high power microwave based undulator has also been successfully demonstrated at SLAC which promises the advantage of dynamic tunability of radiation spectrum and polarization. Such IDs employ transverse elecromagnetic fields which are periodic in both space and time to undulate the electrons. In this paper we develop a detailed theory of the principle of electromagnetic IDs from first principles for both linear and circularmore » polarization modes. The electromagnetic equivalent definitions of undulator period (λ u) and undulator deflection parameter (K) are derived. In the inertial frame where the average momentum of the electron is zero, we obtain the figure-8-like trajectory for the linear polarization mode and the circular trajectory for the circular polarization mode. As a result, the corresponding radiation spectra and the intensity of harmonics is also calculated.« less

  16. Widely tunable narrow-band coherent Terahertz radiation from an undulator at THU

    NASA Astrophysics Data System (ADS)

    Su, X.; Wang, D.; Tian, Q.; Liang, Y.; Niu, L.; Yan, L.; Du, Y.; Huang, W.; Tang, C.

    2018-01-01

    There is anxious demand for intense widely tunable narrow-band Terahertz (THz) radiation in scientific research, which is regarded as a powerful tool for the coherent control of matter. We report the generation of widely tunable THz radiation from a planar permanent magnet undulator at Tsinghua University (THU). A relativistic electron beam is compressed by a magnetic chicane into sub-ps bunch length to excite THz radiation in the undulator coherently. The THz frequency can be tuned from 0.4 THz to 10 THz continuously with narrow-band spectrums when the undulator gap ranges from 23 mm to 75 mm. The measured pulse THz radiation energy from 220 pC bunch is 3.5 μJ at 1 THz and tens of μJ pulse energy (corresponding peak power of 10 MW) can be obtained when excited by 1 nC beam extrapolated from the property of coherent radiation. The experimental results agree well with theoretical predictions, which demonstrates a suitable THz source for the many applications that require intense and widely tunable THz sources.

  17. Diffraction effects in mechanically chopped laser pulses

    NASA Astrophysics Data System (ADS)

    Gambhir, Samridhi; Singh, Mandip

    2018-06-01

    A mechanical beam chopper consists of a rotating disc of regularly spaced wide slits which allow light to pass through them. A continuous light beam, after passing through the rotating disc, is switched-on and switched-off periodically, and a series of optical pulses are produced. The intensity of each pulse is expected to rise and fall smoothly with time. However, a careful study has revealed that the edges of mechanically chopped laser light pulses consist of periodic intensity undulations which can be detected with a photo detector. In this paper, it is shown that the intensity undulations in mechanically chopped laser pulses are produced by diffraction of light from the rotating disc, and a detailed explanation is given of the intensity undulations in mechanically chopped laser pulses. An experiment presented in this paper provides an efficient method to capture a one dimensional diffraction profile of light from a straight sharp-edge in the time domain. In addition, the experiment accurately measures wavelengths of three different laser beams from the undulations in mechanically chopped laser light pulses.

  18. Changes in Functional Mobility and Musculoskeletal Pain After Bariatric Surgery in Teens With Severe Obesity: Teen-Longitudinal Assessment of Bariatric Surgery (LABS) Study.

    PubMed

    Ryder, Justin R; Edwards, Nicholas M; Gupta, Resmi; Khoury, Jane; Jenkins, Todd M; Bout-Tabaku, Sharon; Michalsky, Marc P; Harmon, Carroll M; Inge, Thomas H; Kelly, Aaron S

    2016-09-01

    Severe obesity is associated with mobility limitations and higher incidence of multijoint musculoskeletal pain. It is unknown whether substantial weight loss improves these important outcomes in adolescents with severe obesity. To examine the association of bariatric surgery with functional mobility and musculoskeletal pain in adolescents with severe obesity up to 2 years after surgery. The Teen-Longitudinal Assessment of Bariatric Surgery Study is a prospective, multicenter, observational study, which enrolled 242 adolescents (≤19 years of age) who were undergoing bariatric surgery from March 2007 through February 2012 at 5 US adolescent bariatric surgery centers. This analysis was conducted in November 2015. Roux-en-Y gastric bypass (n = 161), sleeve gastrectomy (n = 67), or laparoscopic adjustable gastric band (n = 14). Participants completed a 400-m walk test prior to bariatric surgery (n = 206) and at 6 months (n = 195), 12 months (n = 176), and 24 months (n = 149) after surgery. Time to completion, resting heart rate (HR), immediate posttest HR, and HR difference (resting HR minus posttest HR) were measured and musculoskeletal pain concerns, during and after the test, were documented. Data were adjusted for age, sex, race/ethnicity, baseline body mass index (calculated as weight in kilograms divided by height in meters squared), and surgical center (posttest HR and HR difference were further adjusted for changes in time to completion). Of the 206 adolescents with severe obesity included in the study, 156 were female (75.7%), the mean (SD) age was 17.1 (1.6) years, and the mean (SD) body mass index was 51.7 (8.5). Compared with baseline, significant improvements were observed at 6 months for the walk test time to completion (mean, 376 seconds; 95% CI, 365-388 to 347 seconds; 95% CI, 340-358; P < .01), resting HR (mean, 84 beats per minute [bpm]; 95% CI, 82-86 to 74 bpm; 95% CI, 72-76), posttest HR (mean, 128 bpm; 95% CI, 125-131 to 113 bpm; 95% CI, 110-116), and HR difference (mean, 40 bpm; 95% CI, 36-42 to 34 bpm; 95% CI, 31-37). These changes in time to completion, resting HR, and HR difference persisted at 12 months and 24 months. Posttest HR further improved from 6 months to 12 months (mean, 113 bpm; 95% CI, 110-116 to 108 bpm; 95% CI, 105-111). There were statistically significant reductions in musculoskeletal pain concerns at all points. These data provide evidence that bariatric surgery in adolescents with severe obesity is associated with significant improvement in functional mobility and in the reduction of walking-related musculoskeletal pain up to 2 years after surgery.

  19. A simple optical system delivering a tunable micrometer pink beam that can compensate for heat-induced deformations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reininger, Ruben; Liu, Zunping; Doumy, Gilles

    2015-06-09

    The radiation from an undulator reflected from one or more optical elements (usually termed `pink-beam') is used in photon-hungry experiments. The optical elements serve as a high-energy cutoff and for focusing purposes. One of the issues with this configuration is maintaining the focal spot dimension as the energy of the undulator is varied, since this changes the heat load absorbed by the first optical element. Finite-element analyses of the power absorbed by a side water-cooled mirror exposed to the radiation emitted by an undulator at the Advanced Photon Source (APS) and at the APS after the proposed upgrade (APSU) revealsmore » that the mirror deformation is very close to a convex cylinder creating a virtual source closer to the mirror than the undulator source. Here a simple optical system is described based on a Kirkpatrick–Baez pair which keeps the focus size to less than 2 µm (in the APSU case) with a working distance of 350 mm despite the heat-load-induced change in source distance. Detailed ray tracings at several photon energies for both the APS and APSU show that slightly decreasing the angle of incidence on the mirrors corrects the change in the `virtual' position of the source. The system delivers more than 70% of the first undulator harmonic with very low higher-orders contamination for energies between 5 and 10 keV.« less

  20. Accuracy assessment of linear spectral mixture model due to terrain undulation

    NASA Astrophysics Data System (ADS)

    Wang, Tianxing; Chen, Songlin; Ma, Ya

    2008-12-01

    Mixture spectra are common in remote sensing due to the limitations of spatial resolution and the heterogeneity of land surface. During the past 30 years, a lot of subpixel model have developed to investigate the information within mixture pixels. Linear spectral mixture model (LSMM) is a simper and more general subpixel model. LSMM also known as spectral mixture analysis is a widely used procedure to determine the proportion of endmembers (constituent materials) within a pixel based on the endmembers' spectral characteristics. The unmixing accuracy of LSMM is restricted by variety of factors, but now the research about LSMM is mostly focused on appraisement of nonlinear effect relating to itself and techniques used to select endmembers, unfortunately, the environment conditions of study area which could sway the unmixing-accuracy, such as atmospheric scatting and terrain undulation, are not studied. This paper probes emphatically into the accuracy uncertainty of LSMM resulting from the terrain undulation. ASTER dataset was chosen and the C terrain correction algorithm was applied to it. Based on this, fractional abundances for different cover types were extracted from both pre- and post-C terrain illumination corrected ASTER using LSMM. Simultaneously, the regression analyses and the IKONOS image were introduced to assess the unmixing accuracy. Results showed that terrain undulation could dramatically constrain the application of LSMM in mountain area. Specifically, for vegetation abundances, a improved unmixing accuracy of 17.6% (regression against to NDVI) and 18.6% (regression against to MVI) for R2 was achieved respectively by removing terrain undulation. Anyway, this study indicated in a quantitative way that effective removal or minimization of terrain illumination effects was essential for applying LSMM. This paper could also provide a new instance for LSMM applications in mountainous areas. In addition, the methods employed in this study could be effectively used to evaluate different algorithms of terrain undulation correction for further study.

  1. An Econometric Examination of the Behavioral Perspective Model in the Context of Norwegian Retailing

    ERIC Educational Resources Information Center

    Sigurdsson, Valdimar; Kahamseh, Saeed; Gunnarsson, Didrik; Larsen, Nils Magne; Foxall, Gordon R.

    2013-01-01

    The behavioral perspective model's (BPM; Foxall, 1990) retailing literature is built on extensive empirical research and techniques that were originally refined in choice experiments in behavioral economics and behavior analysis, and then tested mostly on British consumer panel data. We test the BPM in the context of Norwegian retailing. This…

  2. Towards an Understanding of the Business Process Analyst: An Analysis of Competencies

    ERIC Educational Resources Information Center

    Sonteya, Thembela; Seymour, Lisa

    2012-01-01

    The increase in adoption of business process management (BPM) and service oriented architecture (SOA) has created a high demand for qualified professionals with a plethora of skills. However, despite the growing amount of literature available on the topics of BPM and SOA, little research has been conducted around developing a detailed list of…

  3. Analog Signal Pre-Processing For The Fermilab Main Injector BPM Upgrade

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Saewert, A. L.; Rapisarda, S. M.; Wendt, M.

    2006-11-20

    An analog signal pre-processing scheme was developed, in the framework of the Fermilab Main Injector Beam Position Monitor (BPM) Upgrade, to interface BPM pickup signals to the new digital receiver based read-out system. A key component is the 8-channel electronics module, which uses separate frequency-selective gain stages to acquire 53 MHz bunched proton and 2.5 MHz antiproton signals. Related hardware includes a filter and combiner box to sum pickup electrode signals in the tunnel. A controller module allows local/remote control of gain settings and activation of gain stages and supplies test signals. Theory of operation, system overview, and some designmore » details are presented, as well as first beam measurements of the prototype hardware.« less

  4. A neutral-beam profile monitor with a phosphor screen and a high-sensitivity camera for the J-PARC KOTO experiment

    NASA Astrophysics Data System (ADS)

    Matsumura, T.; Kamiji, I.; Nakagiri, K.; Nanjo, H.; Nomura, T.; Sasao, N.; Shinkawa, T.; Shiomi, K.

    2018-03-01

    We have developed a beam-profile monitor (BPM) system to align the collimators for the neutral beam-line at the Hadron Experimental Facility of J-PARC. The system is composed of a phosphor screen and a CCD camera coupled to an image intensifier mounted on a remote control X- Y stage. The design and detailed performance studies of the BPM are presented. The monitor has a spatial resolution of better than 0.6 mm and a deviation from linearity of less than 1%. These results indicate that the BPM system meets the requirements to define collimator-edge positions for the beam-line tuning. Confirmation using the neutral beam for the KOTO experiment is also presented.

  5. Fast readout algorithm for cylindrical beam position monitors providing good accuracy for particle bunches with large offsets

    NASA Astrophysics Data System (ADS)

    Thieberger, P.; Gassner, D.; Hulsart, R.; Michnoff, R.; Miller, T.; Minty, M.; Sorrell, Z.; Bartnik, A.

    2018-04-01

    A simple, analytically correct algorithm is developed for calculating "pencil" relativistic beam coordinates using the signals from an ideal cylindrical particle beam position monitor (BPM) with four pickup electrodes (PUEs) of infinitesimal widths. The algorithm is then applied to simulations of realistic BPMs with finite width PUEs. Surprisingly small deviations are found. Simple empirically determined correction terms reduce the deviations even further. The algorithm is then tested with simulations for non-relativistic beams. As an example of the data acquisition speed advantage, a Field Programmable Gate Array-based BPM readout implementation of the new algorithm has been developed and characterized. Finally, the algorithm is tested with BPM data from the Cornell Preinjector.

  6. Fast readout algorithm for cylindrical beam position monitors providing good accuracy for particle bunches with large offsets

    DOE PAGES

    Thieberger, Peter; Gassner, D.; Hulsart, R.; ...

    2018-04-25

    Here, a simple, analytically correct algorithm is developed for calculating “pencil” relativistic beam coordinates using the signals from an ideal cylindrical particle beam position monitor (BPM) with four pickup electrodes (PUEs) of infinitesimal widths. The algorithm is then applied to simulations of realistic BPMs with finite width PUEs. Surprisingly small deviations are found. Simple empirically determined correction terms reduce the deviations even further. The algorithm is then tested with simulations for non-relativistic beams. As an example of the data acquisition speed advantage, a FPGA-based BPM readout implementation of the new algorithm has been developed and characterized. Lastly, the algorithm ismore » tested with BPM data from the Cornell Preinjector.« less

  7. Fast readout algorithm for cylindrical beam position monitors providing good accuracy for particle bunches with large offsets

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thieberger, Peter; Gassner, D.; Hulsart, R.

    Here, a simple, analytically correct algorithm is developed for calculating “pencil” relativistic beam coordinates using the signals from an ideal cylindrical particle beam position monitor (BPM) with four pickup electrodes (PUEs) of infinitesimal widths. The algorithm is then applied to simulations of realistic BPMs with finite width PUEs. Surprisingly small deviations are found. Simple empirically determined correction terms reduce the deviations even further. The algorithm is then tested with simulations for non-relativistic beams. As an example of the data acquisition speed advantage, a FPGA-based BPM readout implementation of the new algorithm has been developed and characterized. Lastly, the algorithm ismore » tested with BPM data from the Cornell Preinjector.« less

  8. Fast readout algorithm for cylindrical beam position monitors providing good accuracy for particle bunches with large offsets.

    PubMed

    Thieberger, P; Gassner, D; Hulsart, R; Michnoff, R; Miller, T; Minty, M; Sorrell, Z; Bartnik, A

    2018-04-01

    A simple, analytically correct algorithm is developed for calculating "pencil" relativistic beam coordinates using the signals from an ideal cylindrical particle beam position monitor (BPM) with four pickup electrodes (PUEs) of infinitesimal widths. The algorithm is then applied to simulations of realistic BPMs with finite width PUEs. Surprisingly small deviations are found. Simple empirically determined correction terms reduce the deviations even further. The algorithm is then tested with simulations for non-relativistic beams. As an example of the data acquisition speed advantage, a Field Programmable Gate Array-based BPM readout implementation of the new algorithm has been developed and characterized. Finally, the algorithm is tested with BPM data from the Cornell Preinjector.

  9. MIA analysis of FPGA BPMs and beam optics at APS

    NASA Astrophysics Data System (ADS)

    Ji, Da-Heng; Wang, Chun-Xi; Qin, Qing

    2012-11-01

    Model independent analysis, which was developed for high precision and fast beam dynamics analysis, is a promising diagnostic tool for modern accelerators. We implemented a series of methods to analyze the turn-by-turn BPM data. Green's functions corresponding to the local transfer matrix elements R12 or R34 are extracted from BPM data and fitted with the model lattice using least-square fitting. Here, we report experimental results obtained from analyzing the transverse motion of a beam in the storage ring at the Advanced Photon Source. BPM gains and uncoupled optics parameters are successfully determined. Quadrupole strengths are adjusted for fitting but can not be uniquely determined in general due to an insufficient number of BPMs.

  10. Micropole undulator

    DOEpatents

    Tatchyn, R.O.; Csonka, P.L.; Cremer, J.T.

    1990-12-11

    Micropole undulators for use in the generation of x-rays from moving charged particles are disclosed. Two rows of spaced apart poles are arranged so that each pole produces a magnetic field aligned with all other similar fields. The poles are the ends of C''-shaped magnets. In each row, adjacent poles are separated by spacers made of a superconducting material. 11 figs.

  11. APS undulator and wiggler sources: Monte-Carlo simulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xu, S.L.; Lai, B.; Viccaro, P.J.

    1992-02-01

    Standard insertion devices will be provided to each sector by the Advanced Photon Source. It is important to define the radiation characteristics of these general purpose devices. In this document,results of Monte-Carlo simulation are presented. These results, based on the SHADOW program, include the APS Undulator A (UA), Wiggler A (WA), and Wiggler B (WB).

  12. Advantage and Challenges of $$Nb_3Sn$$ Superconducting Undulators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zlobin, A. V.; Barzi, E.; Turrinoni, D.

    Utilization of Nb3Sn superconducting wires offers the possibility to increase undulators’ nominal operation field and temperature margin, but requires overcoming chal-lenges that are described in this paper. The achievable field levels for a Nb3Sn version of superconducting undulators being developed at APS-ANL and the conductor choice are also presented and discussed.

  13. Simulations of X-ray diffraction of shock-compressed single-crystal tantalum with synchrotron undulator sources.

    PubMed

    Tang, M X; Zhang, Y Y; E, J C; Luo, S N

    2018-05-01

    Polychromatic synchrotron undulator X-ray sources are useful for ultrafast single-crystal diffraction under shock compression. Here, simulations of X-ray diffraction of shock-compressed single-crystal tantalum with realistic undulator sources are reported, based on large-scale molecular dynamics simulations. Purely elastic deformation, elastic-plastic two-wave structure, and severe plastic deformation under different impact velocities are explored, as well as an edge release case. Transmission-mode diffraction simulations consider crystallographic orientation, loading direction, incident beam direction, X-ray spectrum bandwidth and realistic detector size. Diffraction patterns and reciprocal space nodes are obtained from atomic configurations for different loading (elastic and plastic) and detection conditions, and interpretation of the diffraction patterns is discussed.

  14. New beamline optics of the x-ray undulator BW1 at DORIS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hahn, U.; Frahm, R.; Guertler, P.

    1996-12-31

    The X-ray undulator BW1 at the storage ring DORIS is a high brightness source for the spectral range from 2 to 20 keV. The undulator beam is used by three experiments with different distances to the source. The new optical elements allow the adaptation of the focal lengths to the needs of the experimental set-ups. The optical concept consists of a premirror with different optical surfaces, a double crystal monochromator and a focusing second mirror. Sagittal focusing is achieved either by using the cylindrical part of the premirror or by a bend crystal for a monochromatic beam, meridional focusing ismore » done with a pneumatic driven mirror bender for the second mirror.« less

  15. Generalized Models for Rock Joint Surface Shapes

    PubMed Central

    Du, Shigui; Hu, Yunjin; Hu, Xiaofei

    2014-01-01

    Generalized models of joint surface shapes are the foundation for mechanism studies on the mechanical effects of rock joint surface shapes. Based on extensive field investigations of rock joint surface shapes, generalized models for three level shapes named macroscopic outline, surface undulating shape, and microcosmic roughness were established through statistical analyses of 20,078 rock joint surface profiles. The relative amplitude of profile curves was used as a borderline for the division of different level shapes. The study results show that the macroscopic outline has three basic features such as planar, arc-shaped, and stepped; the surface undulating shape has three basic features such as planar, undulating, and stepped; and the microcosmic roughness has two basic features such as smooth and rough. PMID:25152901

  16. Simulations of X-ray diffraction of shock-compressed single-crystal tantalum with synchrotron undulator sources

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tang, M. X.; Zhang, Y. Y.; E, J. C.

    Polychromatic synchrotron undulator X-ray sources are useful for ultrafast single-crystal diffraction under shock compression. Here, simulations of X-ray diffraction of shock-compressed single-crystal tantalum with realistic undulator sources are reported, based on large-scale molecular dynamics simulations. Purely elastic deformation, elastic–plastic two-wave structure, and severe plastic deformation under different impact velocities are explored, as well as an edge release case. Transmission-mode diffraction simulations consider crystallographic orientation, loading direction, incident beam direction, X-ray spectrum bandwidth and realistic detector size. Diffraction patterns and reciprocal space nodes are obtained from atomic configurations for different loading (elastic and plastic) and detection conditions, and interpretation of themore » diffraction patterns is discussed.« less

  17. Absolute measurement of undulator radiation in the extreme ultraviolet

    NASA Astrophysics Data System (ADS)

    Maezawa, H.; Mitani, S.; Suzuki, Y.; Kanamori, H.; Tamamushi, S.; Mikuni, A.; Kitamura, H.; Sasaki, T.

    1983-04-01

    The spectral brightness of undulator radiation emitted by the model PMU-1 incorporated in the SOR-RING, the dedicated synchrotron radiation source in Tokyo, has been studied in the extreme ultraviolet region from 21.6 to 72.9 eV as a function of the electron energy γ, the field parameter K, and the angle of observation ϴ in the absolute scale. A series of measurements covering the first and the second harmonic component of undulator radiation was compared with the fundamental formula λ n= {λ 0}/{2nγ 2}( {1+K 2}/{2}+γϴ 2 and the effects of finite emittance were studied. The brightness at the first peak was smaller than the theoretical value, while an enhanced second harmonic component was observed.

  18. Fish optimize sensing and respiration during undulatory swimming.

    PubMed

    Akanyeti, O; Thornycroft, P J M; Lauder, G V; Yanagitsuru, Y R; Peterson, A N; Liao, J C

    2016-03-24

    Previous work in fishes considers undulation as a means of propulsion without addressing how it may affect other functions such as sensing and respiration. Here we show that undulation can optimize propulsion, flow sensing and respiration concurrently without any apparent tradeoffs when head movements are coupled correctly with the movements of the body. This finding challenges a long-held assumption that head movements are simply an unintended consequence of undulation, existing only because of the recoil of an oscillating tail. We use a combination of theoretical, biological and physical experiments to reveal the hydrodynamic mechanisms underlying this concerted optimization. Based on our results we develop a parsimonious control architecture that can be used by both undulatory animals and machines in dynamic environments.

  19. Fish optimize sensing and respiration during undulatory swimming

    PubMed Central

    Akanyeti, O.; Thornycroft, P. J. M.; Lauder, G. V.; Yanagitsuru, Y. R.; Peterson, A. N.; Liao, J. C.

    2016-01-01

    Previous work in fishes considers undulation as a means of propulsion without addressing how it may affect other functions such as sensing and respiration. Here we show that undulation can optimize propulsion, flow sensing and respiration concurrently without any apparent tradeoffs when head movements are coupled correctly with the movements of the body. This finding challenges a long-held assumption that head movements are simply an unintended consequence of undulation, existing only because of the recoil of an oscillating tail. We use a combination of theoretical, biological and physical experiments to reveal the hydrodynamic mechanisms underlying this concerted optimization. Based on our results we develop a parsimonious control architecture that can be used by both undulatory animals and machines in dynamic environments. PMID:27009352

  20. Relation between detection rate and inappropriate shocks in single versus dual chamber cardioverter-defibrillator – an analysis from the OPTION trial

    PubMed Central

    Kolb, Christof; Sturmer, Marcio; Babuty, Dominique; Sick, Peter; Davy, Jean Marc; Molon, Giulio; Schwab, Jörg Otto; Mantovani, Giuseppe; Wickliffe, Andrew; Lennerz, Carsten; Semmler, Verena; Siot, Pierre-Henri; Reif , Sebastian

    2016-01-01

    The programming of implantable cardioverter-defibrillators (ICDs) influences inappropriate shock rates. The aim of the study is to analyse rates of patients with appropriate and inappropriate shocks according to detection zones in the OPTION trial. All patients received dual chamber (DC) ICDs randomly assigned to be programmed either to single chamber (SC) or to DC settings including PARAD+ algorithm. In a post-hoc analysis, rates of patients with inappropriate and appropriate shocks were calculated for shocks triggered at heart rates ≥170 bpm (ventricular tachycardia zone) and at rates ≥200 bpm (ventricular fibrillation zone). In the SC group, higher rates of patients with total and inappropriate shocks were delivered at heart rates ≥170 bpm than at rates ≥200 bpm (total shocks: 21.1% vs. 16.6%; p = 0.002; inappropriate shocks: 7.6% vs. 4.5%, p = 0.016; appropriate shocks: 15.2% vs. 13.5%; p = n.s.). No such differences were observed in the DC group (total shocks: 14.3% vs. 12.6%; p = n.s.; inappropriate shocks: 3.9% vs. 3.6%; p = n.s.; appropriate shocks: 12.2% vs. 10.4%; p = n.s.). The higher frequency of patients with total shocks with SC settings than with DC settings that benefit from PARAD+ was driven by a higher percentage of patients with inappropriate shocks in the VT zone (170–200 bpm) in the SC population. PMID:26892534

  1. The Brief Problem Monitor-Parent form (BPM-P), a short version of the Child Behavior Checklist: Psychometric properties in Spanish 6- to 8-year-old children.

    PubMed

    Penelo, Eva; de la Osa, Núria; Navarro, José Blas; Domènech, Josep Maria; Ezpeleta, Lourdes

    2017-11-01

    We provide the first validation data on the Spanish version of the Brief Problem Monitor-Parent form (BPM-P), a recently developed abbreviated version of the 120-item Child Behavior Checklist for Ages 6 to 18 (CBCL/6-18) in young schoolchildren. Parents of a community sample of 521 children aged 6-8 answered the CBCL/6-18 yearly, and the 19 BPM-P items were examined; parents also provided different measures of psychopathology. Confirmatory factor analysis of the expected 3-factor model (attention, externalizing, and internalizing) showed adequate fit (root mean square error of approximation, RMSEA ≤ .057), and measurement invariance across sex and age was observed. Internal consistency for the derived scores was satisfactory (ω ≥ .83). Concurrent validity with the equivalent scale scores of the original full CBCL/6-18 (r ≥ .84) and convergent validity with parents' ratings of the Strengths and Difficulties Questionnaire scores (r ≥ .52) were good. BPM-P scores at age 7 showed good predictive accuracy for discriminating the use of mental health services (OR ≥ 1.12), functional impairment (B ≤ -1.25), and the presence of the corresponding disorders diagnosed with an independent clinical interview, both cross-sectionally at age 7 and longitudinally at age 8 (OR ≥ 1.24). The BPM-P provides reliable and valid scores as a very brief follow-up and screening tool for assessing behavioral and emotional problems in young schoolchildren. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  2. Validation of the AVITA BPM15S wrist blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    PubMed

    Kang, Yuan-Yuan; Zeng, Wei-Fang; Zhang, Lu; Li, Yan; Wang, Ji-Guang

    2014-06-01

    The present study aimed to evaluate the accuracy of the automated oscillometric wrist blood pressure monitor AVITA BPM15S for home blood pressure monitoring according to the International Protocol revision 2010 of the European Society of Hypertension. Systolic and diastolic blood pressures were sequentially measured in 33 Chinese adults (15 women, mean age 51 years) using a mercury sphygmomanometer (two observers) and the AVITA BPM15S device (one supervisor). Ninety-nine pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. The AVITA BPM15S device achieved the targets in part 1 of the validation study. The number of absolute differences between the device and observers within 5, 10, and 15 mmHg were 85/99, 94/99, and 98/99, respectively, for systolic blood pressure, and 82/99, 96/99, and 98/99, respectively, for diastolic blood pressure. The device also achieved the criteria in part 2 of the validation study. Thirty-two and 28 participants for systolic and diastolic blood pressure, respectively, had at least two of the three device-observer differences within 5 mmHg (required ≥ 24). No participant had all of the three device-observer comparisons greater than 5 mmHg for systolic or diastolic blood pressure. The AVITA wrist blood pressure monitor BPM15S fulfilled the requirements of the International Protocol revision 2010 and hence can be recommended for home use in an adult population.

  3. Validation of the AVITA BPM17 wrist blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    PubMed

    Kang, Yuan-Yuan; Chen, Qi; Liu, Chang-Yuan; Li, Yan; Wang, Ji-Guang

    2017-08-01

    The aim of the present study was to evaluate the accuracy of the automated oscillometric wrist blood pressure monitor AVITA BPM17 for home blood pressure monitoring according to the International Protocol of the European Society of Hypertension revision 2010. Systolic and diastolic blood pressures were sequentially measured in 33 adult Chinese (19 men, 45.7 years of mean age) using a mercury sphygmomanometer (two observers) and the AVITA BPM17 device (one supervisor). Ninety-nine pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. The AVITA BPM17 device achieved the targets in part 1 of the validation study. The number of absolute differences between device and observers within 5, 10, and 15 mmHg was 94/99, 98/99, and 98/99, respectively, for systolic blood pressure and 92/99, 99/99, and 99/99, respectively, for diastolic blood pressure. The device also fulfilled the criteria in part 2 of the validation study. Overall, 32 participants for both systolic and diastolic blood pressure, respectively, had at least two of the three device-observerss differences within 5 mmHg (required ≥24). None had all the three device-observers comparisons greater than 5 mmHg for systolic and diastolic blood pressure. The AVITA wrist blood pressure monitor BPM17 has passed the requirements of the International Protocol revision 2010, and hence can be recommended for home use in adults.

  4. A Novel WA-BPM Based on the Generalized Multistep Scheme in the Propagation Direction in the Waveguide

    NASA Astrophysics Data System (ADS)

    Ji, Yang; Chen, Hong; Tang, Hongwu

    2017-06-01

    A highly accurate wide-angle scheme, based on the generalized mutistep scheme in the propagation direction, is developed for the finite difference beam propagation method (FD-BPM). Comparing with the previously presented method, the simulation shows that our method results in a more accurate solution, and the step size can be much larger

  5. Notification Event Architecture for Traveler Screening: Predictive Traveler Screening Using Event Driven Business Process Management

    ERIC Educational Resources Information Center

    Lynch, John Kenneth

    2013-01-01

    Using an exploratory model of the 9/11 terrorists, this research investigates the linkages between Event Driven Business Process Management (edBPM) and decision making. Although the literature on the role of technology in efficient and effective decision making is extensive, research has yet to quantify the benefit of using edBPM to aid the…

  6. Correlation of arterial fetal base deficit and lactate changes with severity of variable heart rate decelerations in the near-term ovine fetus.

    PubMed

    Ross, Michael G; Jessie, Marquis; Amaya, Kevin; Matushewski, Brad; Durosier, L Daniel; Frasch, Martin G; Richardson, Bryan S

    2013-04-01

    Recent guidelines classify variable decelerations without detail as to degree of depth. We hypothesized that variable deceleration severity is highly correlated with fetal base deficit accumulation. Seven near-term fetal sheep underwent a series of graded umbilical cord occlusions resulting in mild (30 bpm decrease), moderate (60 bpm decrease), or severe (decrease of 90 bpm to baseline <70 bpm) variable decelerations at 2.5 minute intervals. Mild, moderate, and severe variable decelerations increased fetal base deficit (0.21 ± 0.03, 0.27 ± 0.03, and 0.54 ± 0.09 mEq/L per minute) in direct proportion to severity. During recovery, fetal base deficit cleared at 0.12 mEq/L per minute. In this model, ovine fetuses can tolerate repetitive mild and moderate variable decelerations with minimal change in base deficit and lactate. In contrast, repetitive severe variable decelerations may result in significant base deficit increases, dependent on frequency. Modified guideline differentiation of mild/moderate vs severe variable decelerations may aid in the interpretation of fetal heart rate tracings and optimization of clinical management paradigms. Copyright © 2013 Mosby, Inc. All rights reserved.

  7. The Closed Orbit Measurement System at the DELTA Synchrotron Radiation Facility And First Investigations Concerning the Installation of a Beam Based BPM Calibration System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jankowiak, A.; Wille, K.; /Dortmund U. /SLAC

    2011-08-25

    For a synchrotron radiation source it is necessary to operate a monitoring system to determine the beam position with high resolution and accuracy with respect to the axis of the quadrupole magnets. In this paper the present closed orbit measurement system of the DELTA SR-Facility, concerning the hardware setup, data processing and the calibration methods, will be presented. The results of the calibration measurements and the recent operating experience will be discussed. These results show, that the system is close to the design resolution. But the BPM offsets with respect to the magnetic center of the quadrupole magnets turn outmore » to be not acceptable. For some BPMs they are in the order of several 100 micro m. Therefore it was decided to install a beam based BPM calibration system in the near future . This system should allow to determine the BPM offsets relative to the center of the quadrupole magnets for all 40 BPMs. It is planned to install a system in order to change the focussing strength of each quadrupole individually either in a static or dynamic way.« less

  8. Infrared vibrational spectroscopy of [Ru(bpy)2(bpm)]2+ and [Ru(bpy)3]2+ in the excited triplet state.

    PubMed

    Mukuta, Tatsuhiko; Fukazawa, Naoto; Murata, Kei; Inagaki, Akiko; Akita, Munetaka; Tanaka, Sei'ichi; Koshihara, Shin-ya; Onda, Ken

    2014-03-03

    This work involved a detailed investigation into the infrared vibrational spectra of ruthenium polypyridyl complexes, specifically heteroleptic [Ru(bpy)2(bpm)](2+) (bpy = 2,2'-bipyridine and bpm = 2,2'-bipyrimidine) and homoleptic [Ru(bpy)3](2+), in the excited triplet state. Transient spectra were acquired 500 ps after photoexcitation, corresponding to the vibrational ground state of the excited triplet state, using time-resolved infrared spectroscopy. We assigned the observed bands to specific ligands in [Ru(bpy)2(bpm)](2+) based on the results of deuterium substitution and identified the corresponding normal vibrational modes using quantum-chemical calculations. Through this process, the more complex vibrational bands of [Ru(bpy)3](2+) were assigned to normal vibrational modes. The results are in good agreement with the model in which excited electrons are localized on a single ligand. We also found that the vibrational bands of both complexes associated with the ligands on which electrons are little localized appear at approximately 1317 and 1608 cm(-1). These assignments should allow the study of the reaction dynamics of various photofunctional systems including ruthenium polypyridyl complexes.

  9. Biological Parametric Mapping: A Statistical Toolbox for Multi-Modality Brain Image Analysis

    PubMed Central

    Casanova, Ramon; Ryali, Srikanth; Baer, Aaron; Laurienti, Paul J.; Burdette, Jonathan H.; Hayasaka, Satoru; Flowers, Lynn; Wood, Frank; Maldjian, Joseph A.

    2006-01-01

    In recent years multiple brain MR imaging modalities have emerged; however, analysis methodologies have mainly remained modality specific. In addition, when comparing across imaging modalities, most researchers have been forced to rely on simple region-of-interest type analyses, which do not allow the voxel-by-voxel comparisons necessary to answer more sophisticated neuroscience questions. To overcome these limitations, we developed a toolbox for multimodal image analysis called biological parametric mapping (BPM), based on a voxel-wise use of the general linear model. The BPM toolbox incorporates information obtained from other modalities as regressors in a voxel-wise analysis, thereby permitting investigation of more sophisticated hypotheses. The BPM toolbox has been developed in MATLAB with a user friendly interface for performing analyses, including voxel-wise multimodal correlation, ANCOVA, and multiple regression. It has a high degree of integration with the SPM (statistical parametric mapping) software relying on it for visualization and statistical inference. Furthermore, statistical inference for a correlation field, rather than a widely-used T-field, has been implemented in the correlation analysis for more accurate results. An example with in-vivo data is presented demonstrating the potential of the BPM methodology as a tool for multimodal image analysis. PMID:17070709

  10. Design, test, and calibration of an electrostatic beam position monitor

    NASA Astrophysics Data System (ADS)

    Cohen-Solal, Maurice

    2010-03-01

    The low beta of proton or ion beams favors an electrostatic pickup to measure the transverse beam centroid position. Often papers on beam position monitors (BPM) are focused on a particular aspect of the problem; however, it is important to consider all various issues of a position measurement system. Based on our experience at the IPHI (high intensity injector proton) facility at CEA-Saclay, this paper will address all aspects to design, test, and calibrate a BPM for proton linear accelerators, while emphasizing the determination of the absolute beam position. We present details of the readout electronics, and describe the calibration of the BPM using a test station. For calculation and simulation of the electrical signals we developed a Mathematica script. The error analysis presented, on the basis of six BPMs installed in the high energy section of IPHI, demonstrates the expected accuracy of the position measurement. These studies also identify the parameters that could improve the performance of the beam position control. The experience from these developments is currently being used for the BPM design and test stand dedicated to the Spiral2 accelerator at Ganil-Caen which will deliver heavy ion beams.

  11. Optimized design and structural mechanics of a single-piece composite helicopter driveshaft

    NASA Astrophysics Data System (ADS)

    Henry, Todd C.

    In rotorcraft driveline design, single-piece composite driveshafts have much potential for reducing driveline mass and complexity over multi-segmented metallic driveshafts. The singlepiece shaft concept is enabled by the relatively high fatigue strain capacity of fiber reinforced polymer composites over metals. Challenges for single-piece driveshaft design lie in addressing the self-heating behavior of the composite due to the material damping, as well as, whirling stability, torsional buckling stability, and composite strength. Increased composite temperature due to self-heating reduces the composite strength and is accounted for in this research. The laminate longitudinal stiffness ( Ex) and strength (Fx) are known to be heavily degraded by fiber undulation, however, both are not well understood in compression. The whirling stability (a function of longitudinal stiffness) and the composite strength are strongly influential in driveshaft optimization, and thus are investigated further through the testing of flat and filament wound composite specimens. The design of single-piece composite driveshafts, however, needs to consider many failure criteria, including hysteresis-induced overheating, whirl stability, torsional buckling stability, and material failure by overstress. The present investigation uses multi-objective optimization to investigate the design space which visually highlights design trades. Design variables included stacking sequence, number of laminas, and number of hanger bearings. The design goals were to minimize weight and maximize the lowest factor of safety by adaptively generating solutions to the multi-objective problem. Several design spaces were investigated by examining the effect of misalignment, ambient temperature, and constant power transmission on the optimized solution. Several materials of interest were modeled using experimentally determined elastic properties and novel temperature-dependent composite strength. Compared to the baseline multi-segmented metallic driveline, weight reductions of 43% and 48% were obtained for single-piece flexible and rigid matrix composite shafts. The rigid matrix weight reduction was slightly lower than that seen in the literature due to consideration of shaft misalignment. In filament wound composites, the existence of fiber undulation introduces unique challenges in the prediction of compressive modulus and strength using traditional laminated composite theories. In the current investigation, novel full field strain measurements of compressively loaded specimens were used to evaluate local strain distributions in the region of a 0-deg. undulated lamina in a [0n/90n] s laminate (n=2,4,6) and a 30-deg. undulated lamina in a [30n/-60n] s laminate (n=2,4). Unique to this research, specimens were fabricated with carbon fibers, various amplitudes of undulation, and matrix materials with three different moduli of elasticity. Full-field strains were measured on the free edge and across the width of the compressively loaded specimens using two-dimensional digital image correlation (DIC). The observed strains were highly influenced by the undulation geometry. The longitudinal modulus of a [0n/90n] s laminate was more sensitive to reinforcement undulation when the matrix was flexible rather than rigid. An undulation with an amplitude/length ratio of 0.1 (low for a filament wound cylinder) reduces the average longitudinal modulus of elasticity in the undulation region by approximately 43% and 3% in laminates with flexible and rigid matrices, respectively, relative to a similar material without undulation. Observations of strain on the free edge revealed that fiber undulation caused elevated out-of-plane shear (gamma xz) and through-thickness normal (epsilonzz) strains in regions eventually involved in the fiber microbuckling failure process. A new three dimensional method was derived for the homogenization of a heterogeneous composite laminate consisting of individual anisotropic lamina for which structural coupling (Bij) may occur due to in- and out-of-plane (undulation) fiber reinforcement orientation. Threedimensional elastic constants were calculated by considering a representative volume element taken from the heterogeneous laminate. Three-dimensional elastic constant predictions were validated through comparison with established methods, both two- and three- dimensional. When the new derived three dimensional theory was applied to experimental results, the modulus and strength predictions compared favorably. A series of [+/-theta/89/+/-theta] cylinders with multiple helical fiber angles, winding patterns, and matrix materials were fabricated and tested in compression. Digital image correlation was used for the first time to measure outside surface displacements and strains. Longitudinal and hoop direction strain fluctuations between the undulated and non-undulated regions were found to be of the order of 20-30% of the mean values throughout the cylinders. Qualitatively, these fluctuations can be related to non-classical elastic couplings (Bij) in the anti-symmetric regions of the filament winding pattern. Failure of the cylinder occurred by fiber microbuckling, which initiated near the crossing of circumferential and helical cross-over bands. Based on a statistical analysis of surface strains in the local fiber coordinate system, it was determined that longitudinal compressive and in-plane longitudinal shear strains at incipient microbuckling were two to four times greater than their respective global counterparts. These results indicate the magnitude of strain concentration existing in the cylinders immediately before final failure (possibly during local failure) and highlight the importance of longitudinal compressive (epsilon11) and in-plane longitudinal shear strains (gamma12) in the failure process. A novel local-global approach was used in predicting the longitudinal modulus and strength of filament wound cylinders. Several representative volume elements were chosen to represent the filament winding rhombus, and were used as a basis for homogenization. Strength predictions were augmented with empirical critical distance factors. The average Ex and nu xy prediction error for Conathane DPRN 30917 was 6.8 % and 21 % and the average error for EPON 862 was 9.7 % and 14 % respectively. The strength prediction error was approximately 7.7 % and 24 % for 30917 and EPON 862 with failure location typically at the circumferential undulation by mode sigma 6 (tau12). The failure mode prediction was consistent with experimental observations from filament wound cylinders and flat-undulated specimens of similar lamination arrangement. Additional comparison with previous Adiprene LF750 filament wound cylinder testing produced prediction error of 11.8 % and 8.9 % for longitudinal modulus and strength respectively. The average absolute value of the error, considering every material, for modulus, strength, and Poisson's ratio was 14 %. Application of critical distance factors to flat undulated specimens was deemed unadvisable due to considerably higher strain intensity at failure compared to filament wound cylinders.

  12. Construction of CHESS compact undulator magnets at Kyma

    NASA Astrophysics Data System (ADS)

    Temnykh, Alexander B.; Lyndaker, Aaron; Kokole, Mirko; Milharcic, Tadej; Pockar, Jure; Geometrante, Raffaella

    2015-05-01

    In 2014 KYMA S.r.l. has built two CHESS Compact Undulator (CCU) magnets that are at present installed and successfully operate at the Cornell Electron Storage Ring. This type of undulator was developed for upgrade of Cornell High Energy Synchrotron Source beam-lines, but it can be used elsewhere as well. CCU magnets are compact, lightweight, cost efficient and in-vacuum compatible. They are linearly polarized undulators and have a fixed gap. Magnetic field tuning is achieved by phasing (shifting) top magnetic array relative bottom. Two CCUs constructed by KYMA S.r.l. have 28.4 mm period, 6.5 mm gap, 0.93 T peak field. Magnetic structure is of PPM type, made with NdFeB (40UH grade) permanent magnet material. Transitioning from the laboratory to industrial environment for a novel design required additional evaluation, design adjusting and extensive testing. Particular attention was given to the soldering technique used for fastening of the magnetic blocks to holders. This technique had thus far never been used before for undulator magnet construction by industry. The evaluation included tests of different types of soldering paste, measurements of strength of solder and determining the deformations of the soldered magnet and holder under simulated loading forces. This paper focuses on critical features of the CCU design, results of the soldering technique testing and the data regarding permanent magnets magnetization change due to soldering. In addition it deals with optimization-assisted assembly and the performance of the assembled devices and assesses some of the results of the CCU magnets operation at CESR.

  13. Structure and function of the undulating membrane in spermatozoan propulsion in the toad Bufo marinus

    PubMed Central

    1980-01-01

    Accessory fibers in most sperm surround the axoneme so that their function in propulsion is difficult to assess. In the sperm of the toad Bufo marinus, an accessory fiber is displaced from the axoneme, being connected to it by the thin undulating membrane in such a way that the movement of axoneme and accessory fiber can be viewed independently. The axoneme is highly convoluted in whole mounts, and the axial fiber is straight. Cinemicrographic analysis shows that it is the longer, flexuous fiber, the presumed axoneme, that move actively. The accessory fiber follows it passively with a lower amplitude of movement. The accessory fiber does not move independent of the axoneme, even after demembranation and reactivation of the sperm. On the basis of anatomical relations in the neck region, it appears that the accessory fibers of amphibians are analogous to the dense fibers of mammalian sperm. SDS polyacrylamide gel electrophoresis of demembranated toad sperm tails reveals two principal proteins in addition to the tubulins, the former probably arising from the accessory fibers and the matrix of the undulating membrane. The function of displacing an accessory fiber into an undulating membrane may be to provide stiffness for the tail without incurring an energy deficit large enough to require a long middle piece. A long middle piece is not present in toad sperm, in contrast to those sperm that have accessory fibers around the axoneme. However, the toad sperm suffers a reduction in speed of about one- third, compared with the speed expected for a sperm without an undulating membrane. PMID:6771299

  14. Beam-based calibrations of the BPM offset at C-ADS Injector II

    NASA Astrophysics Data System (ADS)

    Chen, Wei-Long; Wang, Zhi-Jun; Feng, Chi; Dou, Wei-Ping; Tao, Yue; Jia, Huan; Wang, Wang-Sheng; Liu, Shu-Hui; He, Yuan

    2016-07-01

    Beam-based BPM offset calibration was carried out for Injector II at the C-ADS demonstration facility at the Institute of Modern Physics (IMP), Chinese Academy of Science (CAS). By using the steering coils integrated in the quadrupoles, the beam orbit can be effectively adjusted and BPM positions recorded at the Medium Energy Beam Transport of the Injector II Linac. The studies were done with a 2 mA, 2.1 MeV proton beam in pulsed mode. During the studies, the “null comparison method” was applied for the calibration. This method is less sensitive to errors compared with the traditional transmission matrix method. In addition, the quadrupole magnet’s center can also be calibrated with this method. Supported by National Natural Science Foundation of China (91426303, 11525523)

  15. Analog signal pre-processing for the Fermilab Main Injector BPM upgrade

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Saewert, A.L.; Rapisarda, S.M.; Wendt, M.

    2006-05-01

    An analog signal pre-processing scheme was developed, in the framework of the Fermilab Main Injector Beam Position Monitor (BPM) Upgrade, to interface BPM pickup signals to the new digital receiver based read-out system. A key component is the 8-channel electronics module, which uses separate frequency selective gain stages to acquire 53 MHz bunched proton, and 2.5 MHz anti-proton signals. Related hardware includes a filter and combiner box to sum pickup electrode signals in the tunnel. A controller module allows local/remote control of gain settings and activation of gain stages, and supplies test signals. Theory of operation, system overview, and somemore » design details are presented, as well as first beam measurements of the prototype hardware.« less

  16. Geoid undulation accuracy

    NASA Technical Reports Server (NTRS)

    Rapp, Richard H.

    1993-01-01

    The determination of the geoid and equipotential surface of the Earth's gravity field, has long been of interest to geodesists and oceanographers. The geoid provides a surface to which the actual ocean surface can be compared with the differences implying information on the circulation patterns of the oceans. For use in oceanographic applications the geoid is ideally needed to a high accuracy and to a high resolution. There are applications that require geoid undulation information to an accuracy of +/- 10 cm with a resolution of 50 km. We are far from this goal today but substantial improvement in geoid determination has been made. In 1979 the cumulative geoid undulation error to spherical harmonic degree 20 was +/- 1.4 m for the GEM10 potential coefficient model. Today the corresponding value has been reduced to +/- 25 cm for GEM-T3 or +/- 11 cm for the OSU91A model. Similar improvements are noted by harmonic degree (wave-length) and in resolution. Potential coefficient models now exist to degree 360 based on a combination of data types. This paper discusses the accuracy changes that have taken place in the past 12 years in the determination of geoid undulations.

  17. Methods for the computation of detailed geoids and their accuracy

    NASA Technical Reports Server (NTRS)

    Rapp, R. H.; Rummel, R.

    1975-01-01

    Two methods for the computation of geoid undulations using potential coefficients and 1 deg x 1 deg terrestrial anomaly data are examined. It was found that both methods give the same final result but that one method allows a more simplified error analysis. Specific equations were considered for the effect of the mass of the atmosphere and a cap dependent zero-order undulation term was derived. Although a correction to a gravity anomaly for the effect of the atmosphere is only about -0.87 mgal, this correction causes a fairly large undulation correction that was not considered previously. The accuracy of a geoid undulation computed by these techniques was estimated considering anomaly data errors, potential coefficient errors, and truncation (only a finite set of potential coefficients being used) errors. It was found that an optimum cap size of 20 deg should be used. The geoid and its accuracy were computed in the Geos 3 calibration area using the GEM 6 potential coefficients and 1 deg x 1 deg terrestrial anomaly data. The accuracy of the computed geoid is on the order of plus or minus 2 m with respect to an unknown set of best earth parameter constants.

  18. Expected Performance of the LHC Synchrotron-Light Telescope (BSRT) and Abort-Gap Monitor (BSRA)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fisher, Alan; /SLAC

    2010-06-07

    This Report presents calculations of the synchrotron light from proton and lead-ion beams in the LHC at all energies from 0.45 to 7 TeV. It computes the emission from three sources: the uniform-field region of the D3 dipole, the dipole's edge field, and the short undulator just upstream. Light emitted at or near visible wavelengths is assessed for making optical measurements of transverse beam profiles and for monitoring the emptiness of the abort gap in the fill pattern. There is sufficient light for both applications, although both species pass through energy ranges in the ramp with small photon counts. Effectsmore » limiting image resolution are examined, including geometric optics, depth of field, and diffraction. The Report also considers recent suggestions that the undulator, intended to supplement the dipole for low energies, should not be ramped off at high energies and perhaps should not be used at all. We conclude that the undulator is essential at low energy for both species, but that it is possible to leave the undulator on at the cost of some blurring at intermediate energies.« less

  19. Isolated few-cycle radiation from chirped-pulse compression of a superradiant free-electron laser

    DOE PAGES

    Huang, Yen -Chieh; Zhang, Zhen; Chen, Chia -Hsiang; ...

    2015-08-31

    When a short electron bunch traverses an undulator to radiate a wavelength longer than the bunch length, intense superradiance from the electron bunch can quickly deplete the electron’s kinetic energy and lead to generation of an isolated chirped radiation pulse. Here, we develop a theory to describe this novel chirped pulse radiation in a superradiant free-electron laser and show the opportunity to generate isolated few-cycle high-power radiation through chirped-pulse compression after the undulator. The theory is completely characterized by how fast the electron energy is depleted for a given length of an undulator. We further present two design examples atmore » the THz and extreme-ultraviolet wavelengths and numerically generate isolated three- and nine-cycle radiation pulses, respectively.« less

  20. Thermal Modeling and Cryogenic Design of a Helical Superconducting Undulator Cryostat

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shiroyanagi, Y.; Fuerst, J.; Hasse, Q.

    A conceptual design for a helical superconducting undulator (HSCU) for the Advanced Photon Source (APS) at Argonne National Laboratory (ANL) has been completed. The device differs sufficiently from the existing APS planar superconducting undulator (SCU) design to warrant development of a new cryostat based on value engineering and lessons learned from the existing planar SCU. Changes include optimization of the existing cryocooler-based refrigeration system and thermal shield as well as cost reduction through the use of standard vacuum hardware. The end result is a design that provides significantly larger 4.2 K refrigeration margin in a smaller package for greater installationmore » flexibility in the APS storage ring. This paper presents ANSYS-based thermal analysis of the cryostat, including estimated static and dynamic« less

  1. Insertion device calculations with mathematica

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carr, R.; Lidia, S.

    1995-02-01

    The design of accelerator insertion devices such as wigglers and undulators has usually been aided by numerical modeling on digital computers, using code in high level languages like Fortran. In the present era, there are higher level programming environments like IDL{reg_sign}, MatLab{reg_sign}, and Mathematica{reg_sign} in which these calculations may be performed by writing much less code, and in which standard mathematical techniques are very easily used. The authors present a suite of standard insertion device modeling routines in Mathematica to illustrate the new techniques. These routines include a simple way to generate magnetic fields using blocks of CSEM materials, trajectorymore » solutions from the Lorentz force equations for given magnetic fields, Bessel function calculations of radiation for wigglers and undulators and general radiation calculations for undulators.« less

  2. Terahertz radiation source using a high-power industrial electron linear accelerator

    NASA Astrophysics Data System (ADS)

    Kalkal, Yashvir; Kumar, Vinit

    2017-04-01

    High-power (˜ 100 kW) industrial electron linear accelerators (linacs) are used for irradiations, e.g., for pasteurization of food products, disinfection of medical waste, etc. We propose that high-power electron beam from such an industrial linac can first pass through an undulator to generate useful terahertz (THz) radiation, and the spent electron beam coming out of the undulator can still be used for the intended industrial applications. This will enhance the utilization of a high-power industrial linac. We have performed calculation of spontaneous emission in the undulator to show that for typical parameters, continuous terahertz radiation having power of the order of μW can be produced, which may be useful for many scientific applications such as multispectral imaging of biological samples, chemical samples etc.

  3. Vertically polarizing undulator with dynamic compensation of magnetic forces

    DOE PAGES

    Strelnikov, N.; Vasserman, I.; Xu, J.; ...

    2017-01-20

    As part of the R&D program of the LCLS-II project, a novel 3.4-meter-long undulator prototype with horizontal magnetic field and dynamic force compensation has recently been developed at the Advanced Photon Source (APS). Some previous steps in this development were the shorter 0.8-meter-long and 2.8-meter-long prototypes. Extensive mechanical and magnetic testing was carried out for each prototype, and each prototype was magnetically tuned using magnetic shims. Furthermore, the resulting performance of the 3.4-meter-long undulator prototype meets all requirements for the LCLS-II insertion device, including limits on the field integrals, phase errors, higher-order magnetic moments, and electron-beam trajectory for all operationalmore » gaps, as well as the reproducibility and accuracy of the gap settings.« less

  4. Heart Rates of High School Physical Education Students during Team Sports, Individual Sports, and Fitness Activities

    ERIC Educational Resources Information Center

    Laurson, Kelly R.; Brown, Dale D.; Cullen, Robert W.; Dennis, Karen K.

    2008-01-01

    This study examined how activity type influenced heart rates and time spent in target heart rate zones of high school students participating in physical education classes. Significantly higher average heart rates existed for fitness (142 plus or minus 24 beats per minute [bpm]) compared to team (118 plus or minus 24 bpm) or individual (114 plus or…

  5. Ultraviolet carbon lines in the spectrum of the white dwarf BPM 11668

    NASA Technical Reports Server (NTRS)

    Wegner, G.

    1983-01-01

    The southern hemisphere DC white dwarf BPM 11668 has been found to show strong ultraviolet lines of neutral carbon using observations from the IUE satellite. This star seems typical of the growing number of DC white dwarfs found to be of this type and appears to have a carbon abundance near C:He = 0.0001, with an effective temperature of 8500 K.

  6. Bipedal hopping timed to a metronome to detect impairments in anticipatory motor control in people with mild multiple sclerosis.

    PubMed

    Kirkland, Megan C; Chen, Alice; Downer, Matthew B; Holloway, Brett J; Wallack, Elizabeth M; Lockyer, Evan J; Buckle, Natasha C M; Abbott, Courtney L; Ploughman, Michelle

    2018-06-01

    People with mild multiple sclerosis (MS) often report subtle deficits in balance and cognition but display no measurable impairment on clinical assessments. We examined whether hopping to a metronome beat had the potential to detect anticipatory motor control deficits among people with mild MS (Expanded Disability Status Scale ≤ 3.5). Participants with MS (n = 13), matched controls (n = 9), and elderly subjects (n = 13) completed tests of cognition (Montreal Cognitive Assessment (MoCA)) and motor performance (Timed 25 Foot Walk Test (T25FWT)). Participants performed two bipedal hopping tasks: at 40 beats/min (bpm) and 60-bpm in random order. Hop characteristics (length, symmetry, variability) and delay from the metronome beat were extracted from an instrumented walkway and compared between groups. The MS group became more delayed from the metronome beat over time whereas elderly subjects tended to hop closer to the beat (F = 4.52, p = 0.02). Delay of the first hop during 60-bpm predicted cognition in people with MS (R = 0.55, β = 4.64 (SD 4.63), F = 4.85, p = 0.05) but not among control (R = 0.07, p = 0.86) or elderly subjects (R = 0.17, p = 0.57). In terms of hopping characteristics, at 60-bpm, people with MS and matched controls were significantly different from the elderly group. However, at 40-bpm, the MS group was no longer significantly different from the elderly group, even though matched controls and elderly still differed significantly. This new timed hopping test may be able to detect both physical ability, and feed-forward anticipatory control impairments in people with mild MS. Hopping at a frequency of 40-bpm seemed more challenging. Several aspects of anticipatory motor control can be measured: including reaction time to the first metronome cue and the ability to adapt and anticipate the beat over time. Crown Copyright © 2018. Published by Elsevier Ltd. All rights reserved.

  7. Sex Differences in Cardiac Baroreflex Sensitivity after Isometric Handgrip Exercise.

    PubMed

    Teixeira, André L; Ritti-Dias, Raphael; Antonino, Diego; Bottaro, Martim; Millar, Philip J; Vianna, Lauro C

    2018-04-01

    This study aimed to investigate potential sex-related differences on spontaneous cardiac baroreflex sensitivity (cBRS) after acute isometric handgrip (IHG) exercise. Twenty men (age, 23 ± 3 yr) and 20 women (age, 24 ± 4 yr) randomly performed four sets of 2-min IHG exercise (two sets for each limb) at 30% maximal voluntary contraction (experimental) or 3% maximal voluntary contraction (sham). Beat-to-beat heart rate (HR) and arterial blood pressure (BP) were monitored using finger photoplethysmography before and 10, 20, and 30 min after IHG. Spontaneous cBRS was assessed via the sequence technique and cardiac autonomic modulation via time- and frequency-domain HR variability. After IHG, spontaneous cBRS increased during 10 min of recovery in men (Δ13% ± 5%, P = 0.03 vs rest) and increased further in women (Δ23% ± 4%, P < 0.01 vs rest; P = 0.04 vs men). During 20 and 30 min of recovery, cBRS returned to baseline in men but remained elevated in women. HR decreased 10 min after IHG in men (10 min: Δ-2 ± 1 bpm, P < 0.01 vs rest; 20 min: Δ-1 ± 1 bpm, P = 0.39 vs rest; 30 min: Δ1 ± 1 bpm, P = 0.31 vs rest) and throughout recovery in women (10 min: Δ-5 ± 1 bpm, P < 0.01 vs rest; 20 min: Δ-3 ± 1 bpm, P < 0.01 vs rest; 30 min: Δ-2 ± 1 bpm, P < 0.01 vs rest). Systolic BP increased 10 min after IHG and remained elevated during 20 min and 30 min in men (P < 0.05). In women, systolic BP increased during 10 min (P < 0.01) and returned to baseline during 20 and 30 min of recovery. Time-domain HR variability (root mean square of successive differences) was increased during recovery in men and women (P < 0.05). Sham had no effect on any variables. Acute IHG exercise increases cBRS and cardiac vagal activity in healthy young subjects, but the magnitude and the time course of changes in cBRS differ between men and women.

  8. Impact of heart rate in atrial fibrillation versus sinus rhythm on mortality in octogenarian patients with acute coronary syndrome

    PubMed Central

    Li, Shijun; Barywani, Salim; Fu, Michael

    2017-01-01

    Introduction Association of heart rate (HR) with mortality in patients with acute coronary syndrome (ACS) and aged ≥ 80 years are underrepresented in clinical trials. We therefore aimed to investigate the association of HR in atrial fibrillation (AF) versus sinus rhythm (SR) with all-cause mortality in octogenarian patients with ACS. Methods A total of 336 patients with ACS patients and aged ≥ 80 years were enrolled into the current study. The end point of interest was death from any cause. Association of HR in AF versus SR with mortality was analyzed by Kaplan-Meier curve following log-rank test and multivariable Cox regression analysis. Results In total, 63 (87.5%) of patients with AF were dead and 147 (59.8%) of patients with SR were dead during the follow-up period. The best cut-off was 80 bpm, with a sensitivity of 62% and specificity of 66%. HR ≤ 80 bpm in SR but not in AF was associated with better outcome as compared with HR > 80 bpm (Chi-Square = 26.55, Log rank P < 0.001). In SR subgroup, the hazard ratios of HR ≤ 80 bpm were 0.51(95% CI 0.37-0.70, P < 0.001) adjusted for age, 0.46 (95%CI 0.33-0.63, P < 0.001) adjusted for gender, 0.62 (95%CI 0.42- 0.93, P = 0.020) adjusted for multivariables respectively. In AF subgroup, the hazard ratios of HR ≤ 80 bpm were 0.83(95% CI 0.49-1.38, P = 0.464) adjusted for age, 0.96 (95%CI 0.59-1.58, P = 0.882) adjusted for gender, 0.72(95% CI 0.41-1.26, P = 0.249) adjusted for multivariables respectively. Conclusion The current study demonstrates that heart rate is an independent prognostic predictor for all-cause mortality, and HR ≤ 80 bpm is associated with improved outcome in SR but not in AF in octogenarian patients with ACS. PMID:29255559

  9. Electromechanical wave imaging of biologically and electrically paced canine hearts in vivo.

    PubMed

    Costet, Alexandre; Provost, Jean; Gambhir, Alok; Bobkov, Yevgeniy; Danilo, Peter; Boink, Gerard J J; Rosen, Michael R; Konofagou, Elisa E

    2014-01-01

    Electromechanical wave imaging (EWI) has been show capable of directly and entirely non-invasively mapping the trans mural electromechanical activation in all four cardiac chambers in vivo. In this study, we assessed EWI repeatability and reproducibility, as well as its capability of localizing electronic and, for the first time, biological pacing locations in closed-chest, conscious canines. Electromechanical activation was obtained in six conscious animals during normal sinus rhythm (NSR) and idioventricular rhythms occurring in dogs with complete heart block instrumented with electronic and biologic pacemakers (EPM and BPM respectively). After atrioventricular node ablation, dogs were implanted with an EPM in the right ventricular (RV) endocardial apex (n = 4) and two additionally received a BPM at the left ventricular (LV) epicardial base (n = 2). EWI was performed trans thoracically during NSR, BPM and EPM pacing, in conscious dogs, using an unfocused transmit sequence at 2000 frames/s. During NSR, the EW originated at the right atrium (RA), propagated to the left atrium (LA) and emerged from multiple sources in both ventricles. During EPM, the EW originated at the RV apex and propagated throughout both ventricles. During BPM, the EW originated from the LV basal lateral wall and subsequently propagated throughout the ventricles. EWI differentiated BPM from EPM and NSR and identified the distinct pacing origins. Isochrone comparison indicated that EWI was repeatable and reliable. These findings thus indicate the potential for EWI to serve as a simple, non-invasive and direct imaging technology for mapping and characterizing arrhythmias as well as the treatments thereof. Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  10. High Resolution BPM Upgrade for the ATF Damping Ring at KEK

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eddy, N.; Briegel, C.; Fellenz, B.

    2011-08-17

    A beam position monitor (BPM) upgrade at the KEK Accelerator Test Facility (ATF) damping ring has been accomplished, carried out by a KEK/FNAL/SLAC collaboration under the umbrella of the global ILC R&D effort. The upgrade consists of a high resolution, high reproducibility read-out system, based on analog and digital down-conversion techniques, digital signal processing, and also implements a new automatic gain error correction schema. The technical concept and realization as well as results of beam studies are presented. The next generation of linear colliders require ultra-low vertical emittance of <2 pm-rad. The damping ring at the KEK Accelerator Test Facilitymore » (ATF) is designed to demonstrate this mission critical goal. A high resolution beam position monitor (BPM) system for the damping ring is one of the key tools for realizing this goal. The BPM system needs to provide two distnict measurements. First, a very high resolution ({approx}100-200nm) closed-orbit measurement which is averaged over many turns and realized with narrowband filter techniques - 'narrowband mode'. This is needed to monitor and steer the beam along an optimum orbit and to facilitate beam-based alignment to minimize non-linear field effects. Second, is the ability to make turn by turn (TBT) measurements to support optics studies and corrections necessary to achieve the design performance. As the TBT measurement necessitates a wider bandwidth, it is often referred to as 'wideband mode'. The BPM upgrade was initiated as a KEK/SLAC/FNAL collaboration in the frame of the Global Design Initiative of the International Linear Collider. The project was realized and completed using Japan-US funds with Fermilab as the core partner.« less

  11. Taurine supplementation improves economy of movement in the cycle test independently of the detrimental effects of ethanol.

    PubMed

    Paulucio, Dailson; Costa, Bruno M; Santos, Caleb G M; Nogueira, Fernando; Koch, Alexander; Machado, Marco; Velasques, Bruna; Ribeiro, Pedro; Pompeu, Fernando Ams

    2017-12-01

    Taurine (TA) ingestion has been touted as blunting the deleterious effects of ethanol (ET) ingestion on motor performance. This study investigated the effects of ingestion of 0.6 mL·kg -1 of ET, 6 grams of TA, and ethanol in combination with taurine (ET+TA) on economy of movement (EM) and heart rate (HR). Nine volunteers, five female (22 ± 3 years) and four male (26 ± 5 years), participated in a study that used a counterbalanced experimental design. EM and HR were measured for 6 min while the subjects were pedalling at a fixed load 10% below the anaerobic threshold. The blood alcohol concentration (BAC) was similar between ET and ET+TA treatments at 30 min after ingestion and after exercise (12.3 mmol·L -1 vs. 13.7 mmol·L -1 , and 9.7 mmol • L -1 vs 10.9 mmol·L -1 , respectively). EM was significantly different among treatments, with lower mL·W -1 following ingestion of TA (-7.1%, p<0.001) than placebo and ET+TA (-2.45%, p=0.001) compared to ET. HR (bpm) was significantly (p<0.05) higher for ET (137 ± 14 bpm) than the other three treatments (placebo = 129 ± 14 bpm; TA = 127 ± 11 bpm; TA+ET = 133 ± 12 and ET = 137 ± 14 bpm). Taurine improved EM when compared to placebo or ET, and reduced HR when compared to ET. The combination of ET+TA also enhanced EM compared to placebo, and reduced HR in comparison to ET alone. Therefore, these findings indicate that taurine improves EM and counteracts ethanol-induced increases in HR during submaximal exercise.

  12. Validation of the AVITA BPM63S upper arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    PubMed

    Kang, Yuan-Yuan; Zeng, Wei-Fang; Liu, Ming; Li, Yan; Wang, Ji-Guang

    2014-02-01

    The present study aimed to evaluate the accuracy of the AVITA BPM63S upper arm blood pressure monitor for home blood pressure monitoring according to the International Protocol of the European Society of Hypertension revision 2010. Systolic and diastolic blood pressures were sequentially measured in 33 adult Chinese (14 women, mean age of 47 years) using a mercury sphygmomanometer (two observers) and the AVITA BPM63S device (one supervisor). Ninety-nine pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. All the blood pressure requirements were fulfilled. The AVITA BPM63S device achieved the targets in part 1 of the validation study. The number of absolute differences between device and observers within 5, 10, and 15 mmHg was 68/99, 89/99, and 96/99, respectively, for systolic blood pressure, and 75/99, 95/99, and 97/99, respectively, for diastolic blood pressure. The device also achieved the criteria in part 2 of the validation study. Twenty-four and 25 participants for systolic and diastolic blood pressure, respectively, had at least two of the three device-observers differences within 5 mmHg (required ≥24). One and two participants for systolic and diastolic blood pressure, respectively, had all three device-observers differences greater than 5 mmHg. The AVITA BPM63S automated oscillometric upper arm blood pressure monitor has passed the requirements of the International Protocol revision 2010, and hence can be recommended for blood pressure measurement at home in adults.

  13. Heart rate and outcome in heart failure with reduced ejection fraction: Differences between atrial fibrillation and sinus rhythm-A CIBIS II analysis.

    PubMed

    Mulder, Bart A; Damman, Kevin; Van Veldhuisen, Dirk J; Van Gelder, Isabelle C; Rienstra, Michiel

    2017-09-01

    Heart rate has been associated with prognosis in patients with heart failure with reduced ejection fraction (HFREF) and sinus rhythm; whether this also holds true in patients with atrial fibrillation (AF) is unknown. To evaluate cardiac rhythm and baseline heart rate and the influence of outcome in patients with HFREF enrolled in the Cardiac Insufficiency Bisoprolol Study II. In total, 2539 patients were stratified according to their baseline heart rhythm (AF or sinus rhythm) and into quartiles of heart rate (≤70 bpm, 71-78 bpm, 79-90 bpm, and >90 bpm). The primary outcome was all-cause mortality. Mean follow-up was 1.3 years. Mean age was 61 years, mean left ventricular ejection fraction was 28%, and 80% were male. A total of 521 (21%) patients had AF at baseline. The risk associated with all-cause mortality for each 5 bpm increase in heart rate in patients with sinus rhythm (hazard ratio [HR]: 1.06, 95% confidence interval [CI]: 1.01-1.11, P = 0.012) was significantly different from those with AF (HR: 1.00, 95% CI: 0.94-1.07, P = 0.90, P for interaction = 0.041). The risk associated with higher heart rate in sinus rhythm was primarily attributable to excess risk in the highest quartile (HR: 1.64, 95% CI: 1.18-2.30, P = 0.003). Allocation to bisoprolol did not modify the interaction between heart rate, rhythm and outcome. In HFREF patients with AF, a higher heart rate is not associated with increased event rates in contrast to HFREF patients with sinus rhythm. © 2017 Wiley Periodicals, Inc.

  14. Heart rate at admission is a predictor of in-hospital mortality in patients with acute coronary syndromes: Results from 58 European hospitals: The European Hospital Benchmarking by Outcomes in acute coronary syndrome Processes study.

    PubMed

    Jensen, Magnus T; Pereira, Marta; Araujo, Carla; Malmivaara, Anti; Ferrieres, Jean; Degano, Irene R; Kirchberger, Inge; Farmakis, Dimitrios; Garel, Pascal; Torre, Marina; Marrugat, Jaume; Azevedo, Ana

    2018-03-01

    The purpose of this study was to investigate the relationship between heart rate at admission and in-hospital mortality in patients with ST-segment elevation myocardial infarction (STEMI) and non-ST-segment elevation acute coronary syndrome (NSTE-ACS). Consecutive ACS patients admitted in 2008-2010 across 58 hospitals in six participant countries of the European Hospital Benchmarking by Outcomes in ACS Processes (EURHOBOP) project (Finland, France, Germany, Greece, Portugal and Spain). Cardiogenic shock patients were excluded. Associations between heart rate at admission in categories of 10 beats per min (bpm) and in-hospital mortality were estimated by logistic regression in crude models and adjusting for age, sex, obesity, smoking, hypertension, diabetes, known heart failure, renal failure, previous stroke and ischaemic heart disease. In total 10,374 patients were included. In both STEMI and NSTE-ACS patients, a U-shaped relationship between admission heart rate and in-hospital mortality was found. The lowest risk was observed for heart rates between 70-79 bpm in STEMI and 60-69 bpm in NSTE-ACS; risk of mortality progressively increased with lower or higher heart rates. In multivariable models, the relationship persisted but was significant only for heart rates >80 bpm. A similar relationship was present in both patients with or without diabetes, above or below age 75 years, and irrespective of the presence of atrial fibrillation or use of beta-blockers. Heart rate at admission is significantly associated with in-hospital mortality in patients with both STEMI and NSTE-ACS. ACS patients with admission heart rate above 80 bpm are at highest risk of in-hospital mortality.

  15. Attenuated Heart Rate Recovery After Exercise Testing and Risk of Incident Hypertension in Men.

    PubMed

    Jae, Sae Young; Bunsawat, Kanokwan; Fadel, Paul J; Fernhall, Bo; Choi, Yoon-Ho; Park, Jeong Bae; Franklin, Barry A

    2016-09-01

    Although attenuated heart rate recovery (HRR) and reduced heart rate (HR) reserve to maximal exercise testing are associated with adverse cardiovascular outcomes, their relation to incident hypertension in healthy normotensive populations is unclear. We examined the hypothesis that both attenuated HRR and reduced HR reserve to exercise testing are associated with incident hypertension in men. A total of 1,855 participants were selected comprising of healthy, initially normotensive men who underwent peak or symptom-limited treadmill testing at baseline. HRR was calculated as the difference between peak HR during exercise testing and the HR at 2 minutes after exercise cessation. HR reserve was calculated as the percentage of HR reserve (peak HR - resting HR)/(220 - age - resting HR) × 100. During an average 4-year follow-up, 179 (9.6%) men developed hypertension. Incident hypertension was associated with HRR quartiles (Q1 (<42 (bpm)) 12.5%, Q2 (43-49 bpm) 8.5%, Q3 (50-56 bpm) 9.3%, and Q4 (>57 bpm) 8.3%; P = 0.05 for trend). The relative risk (RR) of the incident hypertension in the slowest HRR quartile vs. the fastest HRR quartile was 1.78 (95% confidence interval (CI): 1.14-2.78) after adjustment for confounders. Every 1 bpm increment in HRR was associated with a 2% (RR 0.98, 95% CI: 0.97-0.99) lower risk of incident hypertension after adjusting for potential confounders. In contrast, reduced HR reserve did not predict the risk of incident hypertension. Slow HRR after exercise testing is independently associated with the development of hypertension in healthy normotensive men. © American Journal of Hypertension, Ltd 2016. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. Construction and Commissioning of A 248 m-long Beamline with X-ray Undulator Light Source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Suzuki, Yoshio; Uesugi, Kentaro; Takimoto, Naoki

    2004-05-12

    A medium-length beamline with undulator source, BL20XU at SPring-8, was constructed, and opened to public use. The distance from source point to the end of the beamline is 248 m. By utilizing the long beam transport path, the beamline has advantages for experiment that requires high spatial coherence in hard X-ray regions.

  17. Observation and analysis of self-amplified spontaneous emission at the APS low-energy undulator test line

    NASA Astrophysics Data System (ADS)

    Arnold, N. D.; Attig, J.; Banks, G.; Bechtold, R.; Beczek, K.; Benson, C.; Berg, S.; Berg, W.; Biedron, S. G.; Biggs, J. A.; Borland, M.; Boerste, K.; Bosek, M.; Brzowski, W. R.; Budz, J.; Carwardine, J. A.; Castro, P.; Chae, Y.-C.; Christensen, S.; Clark, C.; Conde, M.; Crosbie, E. A.; Decker, G. A.; Dejus, R. J.; DeLeon, H.; Den Hartog, P. K.; Deriy, B. N.; Dohan, D.; Dombrowski, P.; Donkers, D.; Doose, C. L.; Dortwegt, R. J.; Edwards, G. A.; Eidelman, Y.; Erdmann, M. J.; Error, J.; Ferry, R.; Flood, R.; Forrestal, J.; Freund, H.; Friedsam, H.; Gagliano, J.; Gai, W.; Galayda, J. N.; Gerig, R.; Gilmore, R. L.; Gluskin, E.; Goeppner, G. A.; Goetzen, J.; Gold, C.; Gorski, A. J.; Grelick, A. E.; Hahne, M. W.; Hanuska, S.; Harkay, K. C.; Harris, G.; Hillman, A. L.; Hogrefe, R.; Hoyt, J.; Huang, Z.; Jagger, J. M.; Jansma, W. G.; Jaski, M.; Jones, S. J.; Keane, R. T.; Kelly, A. L.; Keyser, C.; Kim, K.-J.; Kim, S. H.; Kirshenbaum, M.; Klick, J. H.; Knoerzer, K.; Koldenhoven, R. J.; Knott, M.; Labuda, S.; Laird, R.; Lang, J.; Lenkszus, F.; Lessner, E. S.; Lewellen, J. W.; Li, Y.; Lill, R. M.; Lumpkin, A. H.; Makarov, O. A.; Markovich, G. M.; McDowell, M.; McDowell, W. P.; McNamara, P. E.; Meier, T.; Meyer, D.; Michalek, W.; Milton, S. V.; Moe, H.; Moog, E. R.; Morrison, L.; Nassiri, A.; Noonan, J. R.; Otto, R.; Pace, J.; Pasky, S. J.; Penicka, J. M.; Pietryla, A. F.; Pile, G.; Pitts, C.; Power, J.; Powers, T.; Putnam, C. C.; Puttkammer, A. J.; Reigle, D.; Reigle, L.; Ronzhin, D.; Rotela, E. R.; Russell, E. F.; Sajaev, V.; Sarkar, S.; Scapino, J. C.; Schroeder, K.; Seglem, R. A.; Sereno, N. S.; Sharma, S. K.; Sidarous, J. F.; Singh, O.; Smith, T. L.; Soliday, R.; Sprau, G. A.; Stein, S. J.; Stejskal, B.; Svirtun, V.; Teng, L. C.; Theres, E.; Thompson, K.; Tieman, B. J.; Torres, J. A.; Trakhtenberg, E. M.; Travish, G.; Trento, G. F.; Vacca, J.; Vasserman, I. B.; Vinokurov, N. A.; Walters, D. R.; Wang, J.; Wang, X. J.; Warren, J.; Wesling, S.; Weyer, D. L.; Wiemerslage, G.; Wilhelmi, K.; Wright, R.; Wyncott, D.; Xu, S.; Yang, B.-X.; Yoder, W.; Zabel, R. B.

    2001-12-01

    Exponential growth of self-amplified spontaneous emission at 530 nm was first experimentally observed at the Advanced Photon Source low-energy undulator test line in December 1999. Since then, further detailed measurements and analysis of the results have been made. Here, we present the measurements and compare these with calculations based on measured electron beam properties and theoretical expectations.

  18. Assessing the utility of bipolar membranes for use in photoelectrochemical water-splitting cells.

    PubMed

    Vargas-Barbosa, Nella M; Geise, Geoffrey M; Hickner, Michael A; Mallouk, Thomas E

    2014-11-01

    Membranes are important in water-splitting solar cells because they prevent crossover of hydrogen and oxygen. Here, bipolar membranes (BPMs) were tested as separators in water electrolysis cells. Steady-state membrane and solution resistances, electrode overpotentials, and pH gradients were measured at current densities relevant to solar photoelectrolysis. Under forward bias conditions, electrodialysis of phosphate buffer ions creates a pH gradient across a BPM. Under reverse bias, the BPM can maintain a constant buffer pH on both sides of the cell, but a large membrane potential develops. Thus, the BPM does not present a viable solution for electrolysis in buffered electrolytes. However, the membrane potential is minimized when the anode and cathode compartments of the cell contain strongly basic and acidic electrolytes, respectively. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Arm to leg coordination in elite butterfly swimmers.

    PubMed

    Chollet, D; Seifert, L; Boulesteix, L; Carter, M

    2006-04-01

    This study proposed the use of four time gaps to assess arm-to-leg coordination in the butterfly stroke at increasing race paces. Fourteen elite male swimmers swam at four velocities corresponding to the appropriate paces for, respectively, the 400-m, 200-m, 100-m, and 50-m events. The different stroke phases of the arm and leg were identified by video analysis and then used to calculate four time gaps (T1: time gap between entry of the hands in the water and the high break-even point of the first undulation; T2: time gap between the beginning of the hands' backward movement and the low break-even point of the first undulation; T3: time gap between the hands' arrival in a vertical plane to the shoulders and the high break-even point of the second undulation; T4: time gap between the hands' release from the water and the low break-even point of the second undulation), the values of which described the changing relationship of arm to leg movements over an entire stroke cycle. With increases in pace, elite swimmers increased the stroke rate, the relative duration of the arm pull, the recovery and the first downward movement of the legs, and decreased the stroke length, the relative duration of the arm catch phase and the body glide with arms forward (measured by T2), until continuity in the propulsive actions was achieved. Whatever the paces, the T1, T3, and T4 values were close to zero and revealed a high degree of synchronisation at key motor points of the arm and leg actions. This new method to assess butterfly coordination could facilitate learning and coaching by situating the place of the leg undulation in relation with the arm stroke.

  20. Improvement of hospital processes through business process management in Qaem Teaching Hospital: A work in progress.

    PubMed

    Yarmohammadian, Mohammad H; Ebrahimipour, Hossein; Doosty, Farzaneh

    2014-01-01

    In a world of continuously changing business environments, organizations have no option; however, to deal with such a big level of transformation in order to adjust the consequential demands. Therefore, many companies need to continually improve and review their processes to maintain their competitive advantages in an uncertain environment. Meeting these challenges requires implementing the most efficient possible business processes, geared to the needs of the industry and market segments that the organization serves globally. In the last 10 years, total quality management, business process reengineering, and business process management (BPM) have been some of the management tools applied by organizations to increase business competiveness. This paper is an original article that presents implementation of "BPM" approach in the healthcare domain that allows an organization to improve and review its critical business processes. This project was performed in "Qaem Teaching Hospital" in Mashhad city, Iran and consists of four distinct steps; (1) identify business processes, (2) document the process, (3) analyze and measure the process, and (4) improve the process. Implementing BPM in Qaem Teaching Hospital changed the nature of management by allowing the organization to avoid the complexity of disparate, soloed systems. BPM instead enabled the organization to focus on business processes at a higher level.

  1. Hemodynamic variables predict outcome of emergency thoracotomy in the pediatric trauma population.

    PubMed

    Wyrick, Deidre L; Dassinger, Melvin S; Bozeman, Andrew P; Porter, Austin; Maxson, R Todd

    2014-09-01

    Limited data exist regarding indications for resuscitative emergency thoracotomy (ETR) in the pediatric population. We attempt to define the presenting hemodynamic parameters that predict survival for pediatric patients undergoing ETR. We reviewed all pediatric patients (age <18years), entered into the National Trauma Data Bank from 2007 to 2010, who underwent ETR within one hour of ED arrival. Mechanism of injury and hemodynamics were analyzed using Chi squared and Wilcoxon tests. 316 children (70 blunt, 240 penetrating) underwent ETR, 31% (98/316) survived to discharge. Less than 5% of patients survived when presenting SBP was ≤50mmHg or heart rate was ≤70bpm. For blunt injuries there were no survivors with a pulse ≤80bpm or SBP ≤60mmHg. When survivors were compared to nonsurvivors, blood pressure, pulse, and injury type were statistically significant when treated as independent variables and in a logistic regression model. When ETR was performed for SBP ≤50mmHg or for heart rate ≤70bpm less than 5% of patients survived. There were no survivors of blunt trauma when SBP was ≤60mmHg or pulse was ≤80bpm. This review suggests that ETR may have limited benefit in these patients. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. Diagnosis and characterization of mania: Quantifying increased energy and activity in the human behavioral pattern monitor

    PubMed Central

    Perry, William; McIlwain, Meghan; Kloezeman, Karen; Henry, Brook L.; Minassian, Arpi

    2016-01-01

    Increased energy or activity is now an essential feature of the mania of Bipolar Disorder (BD) according to DSM-5. This study examined whether objective measures of increased energy can differentiate manic BD individuals and provide greater diagnostic accuracy compared to rating scales, extending the work of previous studies with smaller samples. We also tested the relationship between objective measures of energy and rating scales. 50 hospitalized manic BD patients were compared to healthy subjects (HCS, n=39) in the human Behavioral Pattern Monitor (hBPM) which quantifies motor activity and goal-directed behavior in an environment containing novel stimuli. Archival hBPM data from 17 schizophrenia patients were used in sensitivity and specificity analyses. Manic BD patients exhibited higher motor activity than HCS and higher novel object interactions. hBPM activity measures were not correlated with observer-rated symptoms, and hBPM activity was more sensitive in accurately classifying hospitalized BD subjects than observer ratings. Although the findings can only be generalized to inpatient populations, they suggest that increased energy, particularly specific and goal-directed exploration, is a distinguishing feature of BD mania and is best quantified by objective measures of motor activity. A better understanding is needed of the biological underpinnings of this cardinal feature. PMID:27138818

  3. Doppler radar sensing of fish physiological motion

    NASA Astrophysics Data System (ADS)

    Hafner, Noah

    The monitoring vital of signs for fish is critical for advancing the study of trophic and energetic strategies, distributions and behavior, environmental impact, and aquaculture approaches. Presented here is a new approach for monitoring fish metabolic state without the trauma and stress associated with capture, surgical ECG, or other implanted sensing systems. Original research contributions include analysis for radar operation under water, development of radar systems for aquatic operation, and application of these systems to non invasively sense the heart and gill motion of fish. Tilapia and Sturgeon were studied to test the efficacy across varied fish body shapes and sizes, ranging from 0.1 to 1.3m in snout to tail length. Monitoring experiments were conducted with eleven tilapia and three sturgeons to assess activity level participated in these experiments, the results from which include activity level monitoring (tilapia: still or fidgeting 94% of time observed), ventilation rate (tilapia: 42 bpm, sturgeon: 145 bpm), and heart rate (tilapia: 41 bpm, sturgeon: 35 bpm). Bland-Altman analysis of radar and ECG measured heart rate indicate agreement between the two measurement techniques and the suitability of radar as an alternative to ECG. The initial steps for developing a system for practical application is also presented including designs for radar system miniaturization and discussion on further characterization steps with less constrained environments.

  4. Revisiting the relationship between exercise heart rate and music tempo preference.

    PubMed

    Karageorghis, Costas I; Jones, Leighton; Priest, David-Lee; Akers, Rose I; Clarke, Adam; Perry, Jennifer M; Reddick, Benjamin T; Bishop, Daniel T; Lim, Harry B T

    2011-06-01

    In the present study, we investigated a hypothesized quartic relationship (meaning three inflection points) between exercise heart rate (HR) and preferred music tempo. Initial theoretical predictions suggested a positive linear relationship (Iwanaga, 1995a, 1995b); however, recent experimental work has shown that as exercise HR increases, step changes and plateaus that punctuate the profile of music tempo preference may occur (Karageorghis, Jones, & Stuart, 2008). Tempi bands consisted of slow (95-100 bpm), medium (115-120 bpm), fast (135-140 bpm), and very fast (155-160 bpm) music. Twenty-eight active undergraduate students cycled at exercise intensities representing 40, 50, 60, 70, 80, and 90% of their maximal HR reserve while their music preference was assessed using a 10-point scale. The Exercise Intensity x Music Tempo interaction was significant, F(6.16, 160.05) = 7.08, p < .001, 7,2 = .21, as was the test for both cubic and quartic trajectories in the exercise HR-preferred-music-tempo relationship (p < .001). Whereas slow tempo music was not preferred at any exercise intensity, preference for fast tempo increased, relative to medium and very fast tempo music, as exercise intensity increased. The implications for the prescription of music in exercise and physical activity contexts are discussed.

  5. Time Series Spectroscopic and Photometric Observations of the Massive DAV BPM 37093

    NASA Astrophysics Data System (ADS)

    Nitta, Atsuko; Kepler, S. O.; Chene, Andre–Nicolas; Koester, D.; Provencal, J. L.; Sullivan, D. J.; Chote, Paul; Safeko, Ramotholo; Kanaan, Antonio; Romero, Alejandra; Corti, Mariela; Corti, Mariela; Kilic, Mukremin; Winget, D. E.

    2015-06-01

    BPM 37093 was the first of only a handful of massive (1.05+/-0.05 M⊙; Bergeron 2004;Koester & Allard 2000) white dwarf pulsators discovered (Kanaan et al. 1992). These stars are particularly interesting because the crystallized mass-fraction as a function of mass and temperature is poorly constrained by observation, yet this process adds 1-2 Gyr uncertainty in ages of the oldest white dwarf stars observed and hence, in the ages of associations that contain them (Abrikosov 1960; Kirzhnits 1960; Salpeter 1961). Last year, we discovered that ESO uses BPM 37093 as a standard star and extracted corresponding spectra from the public archive. The data suggested a large variation in the observed hydrogen line profiles that could potentially be due to pulsations, but the measurement did not reach a detection-quality threshold. To further explore this possibility, though, we obtained 4hrs of continuous time series spectroscopy of BPM 37093 with Gemini in the Northern Spring of 2014. We present our preliminary results from these data along with those from the accompanying time series photometric observations we gathered from Mt. John (New Zealand), South African Astronomical Observatory (SAAO), Panchromatic Robotic optical Monitoring and Polarimetry Telescopes (PROMPT) in Chile, and Complejo Astronomico El Leoncito (Argentina) to support the Gemini observations.

  6. Adhesion of glucosyltransferase phase variants to Streptococcus gordonii bacterium-glucan substrata may involve lipoteichoic acid.

    PubMed

    Vickerman, M M; Jones, G W

    1992-10-01

    Growing Streptococcus gordonii Spp+ phase variants, which have normal levels of glucosyltransferase (GTF) activity, use sucrose to promote their accumulation on surfaces by forming a cohesive bacterium-insoluble glucan polymer mass (BPM). Spp- phase variants, which have lower levels of GTF activity, do not form BPMs and do not remain in BPMs formed by Spp+ cells when grown in mixed cultures. To test the hypothesis that segregation of attached Spp+ and unattached Spp- cells was due to differences in adhesiveness, adhesion between washed, [3H]thymidine-labeled cells and preformed BPM substrata was measured. Unexpectedly, the results showed that cells of both phenotypes, as well as GTF-negative cells, attached equally well to preformed BPMs, indicating that attachment to BPMs was independent of cell surface GTF activity. Initial characterization of this binding interaction suggested that a protease-sensitive component on the washed cells may be binding to lipoteichoic acids sequestered in the BPM, since exogenous lipoteichoic acid inhibited adhesion. Surprisingly, the adhesion of both Spp+ and Spp- cells was markedly inhibited in the presence of sucrose, which also released lipoteichoic acid from the BPM. These in vitro findings suggest that, in vivo, sucrose and lipoteichoic acid may modify dental plaque development by enhancing or inhibiting the attachment of additional bacteria.

  7. One elevated bladder pressure measurement may not be enough to diagnose abdominal compartment syndrome.

    PubMed

    Young, Andrew Joseph; Weber, William; Wolfe, Luke; Ivatury, Rao R; Duane, Therese Marie

    2013-02-01

    Bladder pressure measurements (BPMs) are considered a key component in the diagnosis of abdominal compartment syndrome (ACS). The purpose of this observational review was to determine risk factors of ACS and associated mortality with particular focus on the role of BPM. A retrospective trauma registry and chart review was performed on trauma patients from January 2003 through December 2010. Comparisons were made between patients with and without ACS. There were 3172 patients included in the study of whom 46 had ACS. Patients with ACS were younger, more severely injured, with longer lengths of stay. Logistic regression determined Injury Severity Score (ISS) and urinary catheter days as independent predictors of ACS, whereas independent predictors of mortality included age, ISS, and ACS. Subset analysis demonstrated no association between BPM 20 mmHg or greater and diagnosis of ACS versus no ACS. Logistic regression indicated independent predictors of mortality were number of BPM 20 mmHg or greater and age. Patients with ACS are more severely injured with worse outcomes. An isolated BPM 20 mmHg or greater was not associated with ACS and may be inadequate to independently diagnose ACS. These findings suggest the need for repeat measurements with early intervention if they remain elevated in an effort to decrease mortality associated with ACS.

  8. Adhesion of glucosyltransferase phase variants to Streptococcus gordonii bacterium-glucan substrata may involve lipoteichoic acid.

    PubMed Central

    Vickerman, M M; Jones, G W

    1992-01-01

    Growing Streptococcus gordonii Spp+ phase variants, which have normal levels of glucosyltransferase (GTF) activity, use sucrose to promote their accumulation on surfaces by forming a cohesive bacterium-insoluble glucan polymer mass (BPM). Spp- phase variants, which have lower levels of GTF activity, do not form BPMs and do not remain in BPMs formed by Spp+ cells when grown in mixed cultures. To test the hypothesis that segregation of attached Spp+ and unattached Spp- cells was due to differences in adhesiveness, adhesion between washed, [3H]thymidine-labeled cells and preformed BPM substrata was measured. Unexpectedly, the results showed that cells of both phenotypes, as well as GTF-negative cells, attached equally well to preformed BPMs, indicating that attachment to BPMs was independent of cell surface GTF activity. Initial characterization of this binding interaction suggested that a protease-sensitive component on the washed cells may be binding to lipoteichoic acids sequestered in the BPM, since exogenous lipoteichoic acid inhibited adhesion. Surprisingly, the adhesion of both Spp+ and Spp- cells was markedly inhibited in the presence of sucrose, which also released lipoteichoic acid from the BPM. These in vitro findings suggest that, in vivo, sucrose and lipoteichoic acid may modify dental plaque development by enhancing or inhibiting the attachment of additional bacteria. PMID:1398940

  9. Compensating the electron beam energy spread by the natural transverse gradient of laser undulator in all-optical x-ray light sources.

    PubMed

    Zhang, Tong; Feng, Chao; Deng, Haixiao; Wang, Dong; Dai, Zhimin; Zhao, Zhentang

    2014-06-02

    All-optical ideas provide a potential to dramatically cut off the size and cost of x-ray light sources to the university-laboratory scale, with the combination of the laser-plasma accelerator and the laser undulator. However, the large longitudinal energy spread of the electron beam from laser-plasma accelerator may hinder the way to high brightness of these all-optical light sources. In this paper, the beam energy spread effect is proposed to be significantly compensated by the natural transverse gradient of a laser undulator when properly transverse-dispersing the electron beam. Theoretical analysis and numerical simulations on conventional laser-Compton scattering sources and high-gain all-optical x-ray free-electron lasers with the electron beams from laser-plasma accelerators are presented.

  10. Analysis of a static undulation on the surface of a thin dielectric liquid layer formed by dielectrophoresis forces

    NASA Astrophysics Data System (ADS)

    Brown, Carl V.; McHale, Glen; Mottram, Nigel J.

    2011-07-01

    A layer of insulating liquid of dielectric constant ɛOil and average thickness h- coats a flat surface at y = 0 at which a one-dimensional sinusoidal potential V(x ,0)=VOcos(πx /p) is applied. Dielectrophoresis forces create a static undulation (or "wrinkle") distortion h(x) of period p at the liquid/air interface. Analytical expressions have been derived for the electrostatic energy and the interfacial energy associated with the surface undulation when h(x)=h--(1/2)Acos(2πx /p) yielding a scaling relationship for A as a function of h-, p, VO, ɛOil and the surface tension. The analysis is valid as A/p → 0, and in this limit convergence with numerical simulation of the system is shown.

  11. FEL (free-electron lasers) undulator technology and synchrotron radiation source requirements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robinson, K.; Quimby, D.; Slater, J.

    This paper describes design and construction considerations of the THUNDER undulator, for use in free-electron laser experiments at visible wavelengths. For the parameters of these experiments, an unusually high degree of optimization of the electron-photon interaction is required and, as a result, THUNDER is built to especially high mechanical and magnetic precision. Except for its narrow magnet gap, the 5-meter THUNDER undulator is quite similar to insertion devices under consideration for the proposed 6-GeV storage ring. The engineering and physics approach adopted for this FEL modulator design is directly applicable to insertion device development. The tolerance limits to THUNDER, establishedmore » by modeling and design and achieved through careful control of mechanical and magnetic errors, are essential to the next generation of insertion devices.« less

  12. Initial performances of first undulator-based hard x-ray beamlines of NSLS-II compared to simulations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chubar, Oleg, E-mail: chubar@bnl.gov; Chu, Yong S.; Huang, Xiaojing

    2016-07-27

    Commissioning of the first X-ray beamlines of NSLS-II included detailed measurements of spectral and spatial distributions of the radiation at different locations of the beamlines, from front-ends to sample positions. Comparison of some of these measurement results with high-accuracy calculations of synchrotron (undulator) emission and wavefront propagation through X-ray transport optics, performed using SRW code, is presented.

  13. Calibration of Fast Fiber-Optic Beam Loss Monitors for the Advanced Photon Source Storage Ring Superconducting Undulators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dooling, J.; Harkay, K.; Ivanyushenkov, Y.

    2015-01-01

    We report on the calibration and use of fast fiber-optic (FO) beam loss monitors (BLMs) in the Advanced Photon Source storage ring (SR). A superconducting undulator prototype (SCU0) has been operating in SR Sector 6 (“ID6”) since the beginning of CY2013, and another undulator SCU1 (a 1.1-m length undulator that is three times the length of SCU0) is scheduled for installation in Sector 1 (“ID1”) in 2015. The SCU0 main coil often quenches during beam dumps. MARS simulations have shown that relatively small beam loss (<1 nC) can lead to temperature excursions sufficient to cause quenchingwhen the SCU0windings are nearmore » critical current. To characterize local beam losses, high-purity fused-silica FO cables were installed in ID6 on the SCU0 chamber transitions and in ID1 where SCU1 will be installed. These BLMs aid in the search for operating modes that protect the SCU structures from beam-loss-induced quenching. In this paper, we describe the BLM calibration process that included deliberate beam dumps at locations of BLMs. We also compare beam dump events where SCU0 did and did not quench.« less

  14. Cryogenic Permanent Magnet Undulators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chavanne, J.; Lebec, G.; Penel, C.

    For an in-vacuum undulator operated at small gaps the permanent magnet material needs to be highly resistant to possible electron beam exposure. At room temperature, one generally uses Sm{sub 2}Co{sub 17} or high coercivity NdFeB magnets at the expense of a limited field performance. In a cryogenic permanent magnet undulator (CPMU), at a temperature of around 150 K, any NdFeB grade reveals a coercivity large enough to be radiation resistant. In particular, very high remanence NdFeB material can be used to build undulators with enhanced field and X-ray brilliance at high photon energy provided that the pre-baking of the undulatormore » above 100 deg. C can be eliminated. The ESRF has developed a full scale 2 m long CPMU with a period of 18 mm. This prototype has been in operation on the ID6 test beamline since January 2008. A significant effort was put into the characterization of NdFeB material at low temperature, the development of dedicated magnetic measurement systems and cooling methods. The measured heat budget with beam is found to be larger than expected without compromising the smooth operation of the device. Leading on from this first experience, new CPMUs are currently being considered for the upgrade of the ESRF.« less

  15. Swimming at low Reynolds number: a beginners guide to undulatory locomotion

    NASA Astrophysics Data System (ADS)

    Cohen, Netta; Boyle, Jordan H.

    2010-03-01

    Undulatory locomotion is a means of self-propulsion that relies on the generation and propagation of waves along a body. As a mode of locomotion it is primitive and relatively simple, yet can be remarkably robust. No wonder then, that it is so prevalent across a range of biological scales from motile bacteria to gigantic prehistoric snakes. Key to understanding undulatory locomotion is the body's interplay with the physical environment, which the swimmer or crawler will exploit to generate propulsion, and in some cases, even to generate the underlying undulations. This review focuses by and large on undulators in the low Reynolds number regime, where the physics of the environment can be much more tractable. We review some key concepts and theoretical advances, as well as simulation tools and results applied to selected examples of biological swimmers. In particular, we extend the discussion to some simple cases of locomotion in non-Newtonian media as well as to small animals, in which the nervous system, motor control, body properties and the environment must all be considered to understand how undulations are generated and modulated. To conclude, we review recent progress in microrobotic undulators that may one day become commonplace in applications ranging from toxic waste disposal to minimally invasive surgery.

  16. Effect of hand paddles and parachute on butterfly coordination.

    PubMed

    Telles, Thiago; Barroso, Renato; Barbosa, Augusto Carvalho; Salgueiro, Diego Fortes de Souza; Colantonio, Emilson; Andries Júnior, Orival

    2015-01-01

    This study investigated the effects of hand paddles, parachute and hand paddles plus parachute on the inter-limb coordination of butterfly swimming. Thirteen male swimmers were evaluated in four random maximal intensity conditions: without equipment, with hand paddles, with parachute and with hand paddles + parachute. Arm and leg stroke phases were identified by 2D video analysis to calculate the total time gap (T1: time between hands' entry in the water and high break-even point of the first undulation; T2: time between the beginning of the hand's backward movement and low break-even point of the first undulation; T3: time between the hand's arrival in a vertical plane to the shoulders and high break-even point of the second undulation; T4: time between the hand's release from the water and low break-even point of the second undulation). The swimming velocity was reduced and T1, T2 and T3 increased in parachute and hand paddles + parachute. No changes were observed in T4. Total time gap decreased in parachute and hand paddles + parachute. It is concluded that hand paddles do not influence the arm-to-leg coordination in butterfly, while parachute and hand paddles + parachute do change it, providing a greater propulsive continuity.

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    CARR,R.; CORNACCHIA,M.; EMMA,P.

    The Visible-Infrared SASE Amplifier (VISA) FEL is an experimental device designed to show Self Amplified Spontaneous Emission (SASE) to saturation in the visible light energy range. It will generate a resonant wavelength output from 800--600 nm, so that silicon detectors may be used to characterize the optical properties of the FEL radiation. VISA is the first SASE FEL designed to reach saturation, and its diagnostics will provide important checks of theory. This paper includes a description of the VISA undulator, the magnet measuring and shimming system, and the alignment strategy. VISA will have a 4 m pure permanent magnet undulatormore » comprising four 99 cm segments, each with 55 periods of 18 mm length. The undulator has distributed focusing built into it, to reduce the average beta function of the 70--85 MeV electron beam to about 30 cm. There are four FODO cells per segment. The permanent magnet focusing lattice consists of blocks mounted on either side of the electron beam, in the undulator gap. The most important undulator error parameter for a free electron laser is the trajectory walkoff or lack of overlap of the photon and electron beams. Using pulsed wire magnet measurements and magnet shimming, the authors expect to be able to control trajectory walkoff to less than {+-}50 pm per field gain length.« less

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carr, R.; Cornacchia, M.; Emma, P.

    The Visible-Infrared SASE Amplifier (VISA) FEL is an experimental device designed to show Self Amplified Spontaneous Emission (SASE) to saturation in the visible light energy range. It will generate a resonant wavelength output from 800--600 nm, so that silicon detectors may be used to characterize the optical properties of the FEL radiation. VISA is the first SASE FEL designed to reach saturation, and its diagnostics will provide important checks of theory. This paper includes a description of the VISA undulator, the magnet measuring and shimming system, and the alignment strategy. VISA will have a 4 m pure permanent magnet undulatormore » comprising four 99 cm segments, each with 55 periods of 18 mm length. The undulator has distributed focusing built into it, to reduce the average beta function of the 70--85 MeV electron beam to about 30 cm. There are four FODO cells per segment. The permanent magnet focusing lattice consists of blocks mounted on either side of the electron beam, in the undulator gap. The most important undulator error parameter for a free electron laser is the trajectory walkoff, or lack of overlap of the photon and electron beams. Using pulsed wire magnet measurements and magnet shimming, the authors expect to be able to control trajectory walkoff to less than {+-}50 {micro}m per field gain length.« less

  19. Modeling and estimation of a low degree geopotential model from terrestrial gravity data

    NASA Technical Reports Server (NTRS)

    Pavlis, Nikolaos K.

    1988-01-01

    The development of appropriate modeling and adjustment procedures for the estimation of harmonic coefficients of the geopotential, from surface gravity data was studied, in order to provide an optimum way of utilizing the terrestrial gravity information in combination solutions currently developed at NASA/Goddard Space Flight Center, for use in the TOPEX/POSEIDON mission. The mathematical modeling was based on the fundamental boundary condition of the linearized Molodensky boundary value problem. Atmospheric and ellipsoidal corrections were applied to the surface anomalies. Terrestrial gravity solutions were found to be in good agreement with the satellite ones over areas which are well surveyed (gravimetrically), such as North America or Australia. However, systematic differences between the terrestrial only models and GEMT1, over extended regions in Africa, the Soviet Union, and China were found. In Africa, gravity anomaly differences on the order of 20 mgals and undulation differences on the order of 15 meters, over regions extending 2000 km in diameter, occur. Comparisons of the GEMT1 implied undulations with 32 well distributed Doppler derived undulations gave an RMS difference of 2.6 m, while corresponding comparison with undulations implied by the terrestrial solution gave RMS difference on the order of 15 m, which implies that the terrestrial data in that region are substantially in error.

  20. A configurable electronics system for the ESS-Bilbao beam position monitors

    NASA Astrophysics Data System (ADS)

    Muguira, L.; Belver, D.; Etxebarria, V.; Varnasseri, S.; Arredondo, I.; del Campo, M.; Echevarria, P.; Garmendia, N.; Feuchtwanger, J.; Jugo, J.; Portilla, J.

    2013-09-01

    A versatile and configurable system has been developed in order to monitorize the beam position and to meet all the requirements of the future ESS-Bilbao Linac. At the same time the design has been conceived to be open and configurable so that it could eventually be used in different kinds of accelerators, independent of the charged particle, with minimal change. The design of the Beam Position Monitors (BPMs) system includes a test bench both for button-type pick-ups (PU) and striplines (SL), the electronic units and the control system. The electronic units consist of two main parts. The first part is an Analog Front-End (AFE) unit where the RF signals are filtered, conditioned and converted to base-band. The second part is a Digital Front-End (DFE) unit which is based on an FPGA board where the base-band signals are sampled in order to calculate the beam position, the amplitude and the phase. To manage the system a Multipurpose Controller (MC) developed at ESSB has been used. It includes the FPGA management, the EPICS integration and Archiver Instances. A description of the system and a comparison between the performance of both PU and SL BPM designs measured with this electronics system are fully described and discussed.

  1. Performance of a Combined System Using an X-Ray FEL Oscillator and a High-Gain FEL Amplifier

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gupta, L.; Lindberg, R.; Kim, K. -J.

    The LCLS-II at SLAC will feature a 4 GeV CW superconducting (SC) RF linac [1] that can potentially drive a 5th harmonic X-Ray FEL Oscillator (XFELO) to produce fully coherent, 1 MW photon pulses with a 5 meV bandwidth at 14.4 keV [2]. The XFELO output can serve as the input seed signal for a high-gain FEL amplifier employing fs electron beams from the normal conducting SLAC linac, thereby generating coherent, fs x-ray pulses with TW peak powers using a tapered undulator after saturation [3]. Coherent, intense output at several tens of keV will also be feasible if one considersmore » a harmonic generation scheme. Thus, one can potentially reach the 42 keV photon energy required for the MaRIE project [4] by beginning with an XFELO operating at the 3rd harmonic to produce 14.0 keV photons using a 12 GeV SCRF linac, and then subsequently using the high-gain harmonic generation scheme to generate and amplify the 3th harmonic at 42 keV [5]. We report extensive GINGER simulations that determine an optimized parameter set for the combined system.« less

  2. Lattice Calibration with Turn-By-Turn BPM Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huang, Xiaobiao; /SLAC; Sebek, James

    2012-07-02

    Turn-by-turn beam position monitor (BPM) data from multiple BPMs are fitted with a tracking code to calibrate magnet strengths in a manner similar to the well known LOCO code. Simulation shows that this turn-by-turn method can be a quick and efficient way for optics calibration. The method is applicable to both linacs and ring accelerators. Experimental results for a section of the SPEAR3 ring is also shown.

  3. Formic acid acting as an efficient oxygen scavenger in four-electron reduction of oxygen catalyzed by a heterodinuclear iridium-ruthenium complex in water.

    PubMed

    Fukuzumi, Shunichi; Kobayashi, Takeshi; Suenobu, Tomoyoshi

    2010-09-01

    A heterodinuclear iridium-ruthenium complex [Ir(III)(Cp*)(H(2)O)(bpm)Ru(II)(bpy)(2)](SO(4))(2) (Cp* = eta(5)-pentamethyl-cyclopentadienyl, bpm = 2,2'-bipyrimidine, bpy = 2,2'-bipyridine) acts as an effective catalyst for removal of dissolved O(2) by the four-electron reduction of O(2) with formic acid in water at an ambient temperature.

  4. Beam Position Monitoring in the CSU Accelerator Facility

    NASA Astrophysics Data System (ADS)

    Einstein, Joshua; Vankeuren, Max; Watras, Stephen

    2014-03-01

    A Beam Position Monitoring (BPM) system is an integral part of an accelerator beamline, and modern accelerators can take advantage of newer technologies and designs when creating a BPM system. The Colorado State University (CSU) Accelerator Facility will include four stripline detectors mounted around the beamline, a low-noise analog front-end, and digitization and interface circuitry. The design will support a sampling rate greater than 10 Hz and sub-100 μm accuracy.

  5. Constraining the physics of carbon crystallization through pulsations of a massive DAV BPM37093

    NASA Astrophysics Data System (ADS)

    Nitta, Atsuko; Kepler, S. O.; Chené, André-Nicolas; Koester, D.; Provencal, J. L.; Kleinmani, S. J.; Sullivan, D. J.; Chote, Paul; Sefako, Ramotholo; Kanaan, Antonio; Romero, Alejandra; Corti, Mariela; Kilic, Mukremin; Montgomery, M. H.; Winget, D. E.

    We are trying to reduce the largest uncertainties in using white dwarf stars as Galactic chronometers by understanding the details of carbon crystalliazation that currently result in a 1-2 Gyr uncertainty in the ages of the oldest white dwarf stars. We expect the coolest white dwarf stars to have crystallized interiors, but theory also predicts hotter white dwarf stars, if they are massive enough, will also have some core crystallization. BPM 37093 is the first discovered of only a handful of known massive white dwarf stars that are also pulsating DAV, or ZZ Ceti, variables. Our approach is to use the pulsations to constrain the core composition and amount of crystallization. Here we report our analysis of 4 hours of continuous time series spectroscopy of BPM 37093 with Gemini South combined with simultaneous time-series photometry from Mt. John (New Zealand), SAAO, PROMPT, and Complejo Astronomico El Leoncito (CASLEO, Argentina).

  6. Constrained independent component analysis approach to nonobtrusive pulse rate measurements

    NASA Astrophysics Data System (ADS)

    Tsouri, Gill R.; Kyal, Survi; Dianat, Sohail; Mestha, Lalit K.

    2012-07-01

    Nonobtrusive pulse rate measurement using a webcam is considered. We demonstrate how state-of-the-art algorithms based on independent component analysis suffer from a sorting problem which hinders their performance, and propose a novel algorithm based on constrained independent component analysis to improve performance. We present how the proposed algorithm extracts a photoplethysmography signal and resolves the sorting problem. In addition, we perform a comparative study between the proposed algorithm and state-of-the-art algorithms over 45 video streams using a finger probe oxymeter for reference measurements. The proposed algorithm provides improved accuracy: the root mean square error is decreased from 20.6 and 9.5 beats per minute (bpm) for existing algorithms to 3.5 bpm for the proposed algorithm. An error of 3.5 bpm is within the inaccuracy expected from the reference measurements. This implies that the proposed algorithm provided performance of equal accuracy to the finger probe oximeter.

  7. Creating an EPICS Based Test Stand Development System for a BPM Digitizer of the Linac Coherent Light Source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    2011-06-22

    The Linac Coherent Light Source (LCLS) is required to deliver a high quality electron beam for producing coherent X-rays. As a result, high resolution beam position monitoring is required. The Beam Position Monitor (BPM) digitizer acquires analog signals from the beam line and digitizes them to obtain beam position data. Although Matlab is currently being used to test the BPM digitizer?s functions and capability, the Controls Department at SLAC prefers to use Experimental Physics and Industrial Control Systems (EPICS). This paper discusses the transition of providing similar as well as enhanced functionalities, than those offered by Matlab, to test themore » digitizer. Altogether, the improved test stand development system can perform mathematical and statistical calculations with the waveform signals acquired from the digitizer and compute the fast Fourier transform (FFT) of the signals. Finally, logging of meaningful data into files has been added.« less

  8. Best practicable means (BPM) and as low as reasonably practicable (ALARP) in action at Sellafield.

    PubMed

    Morley, Bob

    2004-03-01

    Operators within the UK nuclear industry are required to employ 'best practicable means' (BPM) to control and minimise radioactive discharges. The requirement for the use of BPM is in order to ensure that doses from discharges are as low as reasonably practicable (ALARP). This facet is increasingly becoming the principal feature of discharge authorisations issued by the Environment Agencies under the Radioactive Substances Act, 1993 (RSA 93), which are enforceable by law. It is important to state at the outset, however, that scientific assessments to date indicate that there are no expectations of environmental harm from authorised discharges, even where those discharges have historically been up to two orders of magnitude higher than current levels. There is also no evidence to indicate that foreseeable future discharges from the Sellafield site will make any contribution to environmental harm.

  9. Analytical expression for position sensitivity of linear response beam position monitor having inter-electrode cross talk

    NASA Astrophysics Data System (ADS)

    Kumar, Mukesh; Ojha, A.; Garg, A. D.; Puntambekar, T. A.; Senecha, V. K.

    2017-02-01

    According to the quasi electrostatic model of linear response capacitive beam position monitor (BPM), the position sensitivity of the device depends only on the aperture of the device and it is independent of processing frequency and load impedance. In practice, however, due to the inter-electrode capacitive coupling (cross talk), the actual position sensitivity of the device decreases with increasing frequency and load impedance. We have taken into account the inter-electrode capacitance to derive and propose a new analytical expression for the position sensitivity as a function of frequency and load impedance. The sensitivity of a linear response shoe-box type BPM has been obtained through simulation using CST Studio Suite to verify and confirm the validity of the new analytical equation. Good agreement between the simulation results and the new analytical expression suggest that this method can be exploited for proper designing of BPM.

  10. Effect of the type of ion exchange membrane on performance, ion transport, and pH in biocatalyzed electrolysis of wastewater.

    PubMed

    Rozendal, R A; Sleutels, T H J A; Hamelers, H V M; Buisman, C J N

    2008-01-01

    Previous studies have shown that the application of cation exchange membranes (CEMs) in bioelectrochemical systems running on wastewater can cause operational problems. In this paper the effect of alternative types of ion exchange membrane is studied in biocatalyzed electrolysis cells. Four types of ion exchange membranes are used: (i) a CEM, (ii) an anion exchange membrane (AEM), (iii) a bipolar membrane (BPM), and (iv) a charge mosaic membrane (CMM). With respect to the electrochemical performance of the four biocatalyzed electrolysis configurations, the ion exchange membranes are rated in the order AEM > CEM > CMM > BPM. However, with respect to the transport numbers for protons and/or hydroxyl ions (t(H/OH)) and the ability to prevent pH increase in the cathode chamber, the ion exchange membranes are rated in the order BPM > AEM > CMM > CEM.

  11. Syncope During Competitive Events: Interrogating Heart Rate Monitor Watches May Be Useful!

    PubMed

    Thabouillot, Oscar; Bostanci, Kevin; Bouvier, Francois; Dumitrescu, Nicolae; Stéfuriac, Maria; Paule, Philippe; Roche, Nicolas-Charles

    2017-12-01

    This is a case report of a 45-year-old man who reported complete amnesia during the very first kilometer of a 10-km run. He was wearing a heart rate monitor (HRM). The interrogation of his HRM watch showed 200 bpm tachycardia beginning in the first kilometer and increasing up to 220 bpm during the last kilometer. The patient was asked to wear a Holter-monitor (Holter Research Laboratory; Helena, Montana USA) electrocardiogram (ECG) while practicing a training session. This examination allowed for the diagnosis of an adrenergic paroxysmal atrial fibrillation (AF) with an impressive auriculo-ventricular conduction over 260 bpm. This case highlights that non-medical devices, such as connected watches, can be helpful to diagnose arrhythmias. Thabouillot O , Bostanci K , Bouvier F , Dumitrescu N , Stéfuriac M , Paule P , Roche NC . Syncope during competitive events: interrogating heart rate monitor watches may be useful! Prehosp Disaster Med. 2017;32(6):691-693.

  12. Effects of hot-iron branding on heart rate, breathing rate and behaviour of anaesthetised Steller sea lions.

    PubMed

    Walker, K A; Mellish, J E; Weary, D M

    2011-10-01

    This study assessed the heart rate, breathing rate and behavioural responses of 12 juvenile Steller sea lions during hot-iron branding under isoflurane anaesthesia. Physiological and behavioural measures were recorded in four periods: baseline (five minutes), sham branding (one minute), branding (approximately 2.7 minutes) and postbranding (five minutes). No difference in heart rate was noted from baseline to sham branding, but heart rate increased from mean (sem) 78.3 (2.4) bpm in the baseline period to 85.6 (2.5) bpm in the branding period. Heart rate remained elevated in the postbranding period, averaging 84.7 (2.5) bpm. Breathing rate averaged 2.5 (1.0) breaths/minute in the baseline and sham branding periods increased to 8.9 (1.0) breaths/minute during branding, but returned to baseline by the postbranding period. Behaviourally, half of the sea lions exhibited trembling and head and shoulder movements during branding.

  13. BPM analysis of all-optical fiber interferometric sensor based on a U-shape microcavity

    NASA Astrophysics Data System (ADS)

    Wu, Hongbin; Yuan, Lei; Wang, Sumei; Zhao, Longjiang; Cao, Zhitao

    2014-02-01

    Reflectivity spectrum of beam propagation method (BPM), for the first time to the best of our knowledge, is realized and utilized to model all-optical fiber interferometric sensor formed by a U-shape microcavity embedded in a single mode optical fiber and illustrate the principle of sensor structures varied by the length and the depth of U-shape microcavity. BPM analysis gives a constructive guideline to get a high interferometric fringe visibility which is most important for sensing application. The simulated results are completely in agreement with the interferometric sensor principle of Fabry-Perot interferometer (FPI) theory. With the conclusion of FPI sensor, refractive index (RI) sensitivity and temperature sensitivity are then simulated and obtained as 1049+/-5.2nm/RIU (refractive index unit) within RI range of solutions and 1.04+/-0.03pm/°C respectively.

  14. Constrained independent component analysis approach to nonobtrusive pulse rate measurements.

    PubMed

    Tsouri, Gill R; Kyal, Survi; Dianat, Sohail; Mestha, Lalit K

    2012-07-01

    Nonobtrusive pulse rate measurement using a webcam is considered. We demonstrate how state-of-the-art algorithms based on independent component analysis suffer from a sorting problem which hinders their performance, and propose a novel algorithm based on constrained independent component analysis to improve performance. We present how the proposed algorithm extracts a photoplethysmography signal and resolves the sorting problem. In addition, we perform a comparative study between the proposed algorithm and state-of-the-art algorithms over 45 video streams using a finger probe oxymeter for reference measurements. The proposed algorithm provides improved accuracy: the root mean square error is decreased from 20.6 and 9.5 beats per minute (bpm) for existing algorithms to 3.5 bpm for the proposed algorithm. An error of 3.5 bpm is within the inaccuracy expected from the reference measurements. This implies that the proposed algorithm provided performance of equal accuracy to the finger probe oximeter.

  15. Successive approximation algorithm for beam-position-monitor-based LHC collimator alignment

    NASA Astrophysics Data System (ADS)

    Valentino, Gianluca; Nosych, Andriy A.; Bruce, Roderik; Gasior, Marek; Mirarchi, Daniele; Redaelli, Stefano; Salvachua, Belen; Wollmann, Daniel

    2014-02-01

    Collimators with embedded beam position monitor (BPM) button electrodes will be installed in the Large Hadron Collider (LHC) during the current long shutdown period. For the subsequent operation, BPMs will allow the collimator jaws to be kept centered around the beam orbit. In this manner, a better beam cleaning efficiency and machine protection can be provided at unprecedented higher beam energies and intensities. A collimator alignment algorithm is proposed to center the jaws automatically around the beam. The algorithm is based on successive approximation and takes into account a correction of the nonlinear BPM sensitivity to beam displacement and an asymmetry of the electronic channels processing the BPM electrode signals. A software implementation was tested with a prototype collimator in the Super Proton Synchrotron. This paper presents results of the tests along with some considerations for eventual operation in the LHC.

  16. Model-independent analysis of the Fermilab Tevatron turn-by-turn beam position monitor measurements

    NASA Astrophysics Data System (ADS)

    Petrenko, A. V.; Valishev, A. A.; Lebedev, V. A.

    2011-09-01

    Coherent transverse beam oscillations in the Tevatron were analyzed with the model-independent analysis (MIA) technique. This allowed one to obtain the model-independent values of coupled betatron amplitudes, phase advances, and dispersion function around the ring from a single dipole kick measurement. In order to solve the MIA mode mixing problem which limits the accuracy of determination of the optical functions, we have developed a new technique of rotational MIA mode untangling. The basic idea is to treat each beam position monitor (BPM) as two BPMs separated in a ring by exactly one turn. This leads to a simple criterion of MIA mode separation: the betatron phase advance between any BPM and its counterpart shifted by one turn should be equal to the betatron tune and therefore should not depend on the BPM position in the ring. Furthermore, we describe a MIA-based technique to locate vibrating magnets in a storage ring.

  17. The Effect of Physical Resistance Training on Baroreflex Sensitivity of Hypertensive Rats.

    PubMed

    Gomes, Moisés Felipe Pereira; Borges, Mariana Eiras; Rossi, Vitor de Almeida; Moura, Elizabeth de Orleans C de; Medeiros, Alessandra

    2017-01-01

    Baroreceptors act as regulators of blood pressure (BP); however, its sensitivity is impaired in hypertensive patients. Among the recommendations for BP reduction, exercise training has become an important adjuvant therapy in this population. However, there are many doubts about the effects of resistance exercise training in this population. To evaluate the effect of resistance exercise training on BP and baroreceptor sensitivity in spontaneously hypertensive rats (SHR). Rats SHR (n = 16) and Wistar (n = 16) at 8 weeks of age, at the beginning of the experiment, were randomly divided into 4 groups: sedentary control (CS, n = 8); trained control (CT, n = 8); sedentary SHR (HS, n = 8) and trained SHR (HT, n = 8). Resistance exercise training was performed in a stairmaster-type equipment (1.1 × 0.18 m, 2 cm between the steps, 80° incline) with weights attached to their tails, (5 days/week, 8 weeks). Baroreceptor reflex control of heart rate (HR) was tested by loading/unloading of baroreceptors with phenylephrine and sodium nitroprusside. Resistance exercise training increased the soleus muscle mass in SHR when compared to HS (HS 0.027 ± 0.002 g/mm and HT 0.056 ± 0.003 g/mm). Resistance exercise training did not alter BP. On the other hand, in relation to baroreflex sensitivity, bradycardic response was improved in the TH group when compared to HS (HS -1.3 ± 0.1 bpm/mmHg and HT -2.6 ± 0.2 bpm/mmHg) although tachycardia response was not altered by resistance exercise (CS -3.3 ± 0.2 bpm/mmHg, CT -3.3 ± 0.1 bpm/mmHg, HS -1.47 ± 0.06 bpm/mmHg and HT -1.6 ± 0.1 bpm/mmHg). Resistance exercise training was able to promote improvements on baroreflex sensitivity of SHR rats, through the improvement of bradycardic response, despite not having reduced BP. Os barorreceptores atuam como reguladores da pressão arterial (PA); no entanto, sua sensibilidade encontra-se prejudicada em pacientes hipertensos. Dentre as recomendações para a redução da PA, o treinamento físico tem se tornado um importante adjunto na terapia dessa população. Porém, ainda há diversos questionamentos sobre os efeitos de treinamento físico resistido nessa população. Avaliar o efeito do treinamento físico resistido na PA e na sensibilidade de barorreceptores em ratos espontaneamente hipertensos (SHR). Ratos SHR (n = 16) e Wistar (n = 16) com 08 semanas de idade foram aleatoriamente divididos em 4 grupos: controle sedentário (CS, n = 8); controle treinado (CT, n = 8); SHR sedentário (HS, n = 8) e SHR treinado (HT, n = 8). O treinamento físico foi realizado em aparato com degraus (1,1 × 0,18 m, 2 cm entre os degraus, 80° inclinação) com peso fixado na cauda, (5 vezes por semana durante 8 semanas). O controle barorreflexo da frequência cardíaca (FC) foi testado com estímulos de fenilefrina e nitroprussiato de sódio. O treinamento resistido foi capaz de aumentar a massa muscular do sóleo em ratos SHR (HS 0,027 ± 0,002 g/mm e HT 0,056 ± 0,003 g/mm). Não houve alteração da PA com o treinamento. Por outro lado, houve melhora na resposta bradicárdica da sensibilidade barorreflexa no grupo HT (HS -1,3 ± 0,1 bpm/mmHg e HT -2,6 ± 0,2 bpm/mmHg), no entanto, a resposta taquicárdica não foi alterada pelo exercício resistido (CS -3,3 ± 0,2 bpm/mmHg, CT -3,3 ± 0,1 bpm/mmHg, HS -1,47 ± 0,06 e HT -1,6 ± 0,1). O exercício físico resistido foi capaz de otimizar a sensibilidade barorreflexa dos ratos SHR por meio da melhora à resposta bradicárdica, apesar de não alterar a PA.

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sasaki, S.; McNulty, I.; Shimada, T.

    We investigate use of an APPLE-type undulator for generating Laguerre-Gaussian (LG) and Hermite-Gaussian (HG) mode beams. We find that the second harmonic radiation in the circular mode corresponds to an LG beam with l=1, and the second harmonic in the linear mode corresponds to an HG beam with l=1. The combination of an APPLE undulator and conventional monochromator optics may provide an opportunity for a new type of experimental research in the synchrotron radiation community.

  19. Soft X-ray FEL simulation in PAL-XFEL

    NASA Astrophysics Data System (ADS)

    Shim, Chi Hyun; Ko, In Soo; Parc, Yong Woon; Han, Jang Hui

    2015-10-01

    The soft X-ray beamline in the Pohang Accelerator Laboratory X-ray Free Electron Laser (PAL-XFEL) will provide a photon beam with a wavelength from 1 nm to 3 nm in the self-amplified spontaneous emission (SASE) mode by using an electron beam with a 3.15-GeV beam energy. Linearly polarized radiation will be supplied by using six planar undulators (PUs). The linearly-polarized radiation powers at 1 (3) nm can reach 10.2 (30) GW. Polarization of the radiation will be controlled by applying the reverse undulator tapering scheme to the PUs and adding two helical undulators (HUs). The circularly-polarized radiation powers at 1 (3) nm will be 3.11 (11.73) GW. The degrees of circular polarization will be larger than 0.99 for both wavelengths. Three options for the future upgrade of the beamline to increase the radiation power are proposed.

  20. Detecting spatial patterns of rivermouth processes using a geostatistical framework for near-real-time analysis

    USGS Publications Warehouse

    Xu, Wenzhao; Collingsworth, Paris D.; Bailey, Barbara; Carlson Mazur, Martha L.; Schaeffer, Jeff; Minsker, Barbara

    2017-01-01

    This paper proposes a geospatial analysis framework and software to interpret water-quality sampling data from towed undulating vehicles in near-real time. The framework includes data quality assurance and quality control processes, automated kriging interpolation along undulating paths, and local hotspot and cluster analyses. These methods are implemented in an interactive Web application developed using the Shiny package in the R programming environment to support near-real time analysis along with 2- and 3-D visualizations. The approach is demonstrated using historical sampling data from an undulating vehicle deployed at three rivermouth sites in Lake Michigan during 2011. The normalized root-mean-square error (NRMSE) of the interpolation averages approximately 10% in 3-fold cross validation. The results show that the framework can be used to track river plume dynamics and provide insights on mixing, which could be related to wind and seiche events.

Top